Powered by Deep Web Technologies
Note: This page contains sample records for the topic "madrid fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Paleoseismology study of the Cache River Valley, southern Illinois, and New Madrid seismic zone, southeast Missouri and northeast Kansas  

E-Print Network (OSTI)

Our understanding of earthquake hazard in the mid-continent region of the United States has benefited greatly from paleoseismology studies. Numerous earthquake-induced features have been documented throughout the region, though the timing and location of prehistoric earthquakes needs to be better constrained. Some areas of the mid-continent, such as the Cache River Valley (CRV) of southern Illinois, have not been studied in the detail of the New Madrid seismic zone, thus the earthquake hazard is poorly understood. l have conducted a paleoseismology study of the CRV and the New Madrid seismic zone to add to the earthquake chronology of the mid-continent region. Field reconnaissance in the CRV during the summer and fall of 1998 yielded no new evidence of recent faulting or liquefaction. It is important to note, however, that this time period was characterized by abnormally high river levels that significantly reduced cutback and ditch exposures. One previously discovered liquefaction feature, that was exposed, was excavated and logged in detail. Organic matter from this site indicates that the maximum age of this feature is 3421-2861 BC. The lack of soil development and weathering in the dike, however, suggests that it is probably less than 2000 years old. Given the probable age of this feature and the current paleoearthquake chronology, the source for this feature is most likely the New Madrid Seismic Zone. Additional work, concentrating along the balks of the lower Cache River and its larger tributaries is needed during low water periods to further determine the distribution and age of earthquake-induced deformation of this region. Data from several trenches at the Sigman site, northeast Arkansas, suggest that the liquefaction at this site likely occurred during the 1811-1812 New Madrid earthquake sequence. Organic matter from several stratigraphic horizons associated with two stacked sand blows at the Braggadocio site, southeastern Missouri, yielded modern dates. In contrast, the degree of soil development on the sand blows suggests that these features are several hundred years old. This discrepancy suggests that the dated samples were actually modern roots growing through the section. As a result, additional trenching and dating are needed at this site.

Noonan, Brian James

1999-01-01T23:59:59.000Z

2

Thermal Waters Along The Konocti Bay Fault Zone, Lake County...  

Open Energy Info (EERE)

Thermal Waters Along The Konocti Bay Fault Zone, Lake County, California- A Re-Evaluation Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: Thermal...

3

Structural geology of Shawneetown fault zone, Southeastern Illinois  

SciTech Connect

Vertical movements of crustal blocks along the narrow east-west-trending Shawneetown fault zone in southeastern Illinois occurred between Early Permian and Late Cretaceous. The main blocks moved vertically and retured to roughly their orignal positions so that strata now show little relative offset across the fault zone. However, individual faults with displacements up to 3,500 ft (1,070 m) bound narrow slices of steeply tilted or overturned strata resulting in a juxtaposition of Kinderhookian (Lower Mississippian) and Upper Devonian strata with Lower Pennsylvanina strata. The bedrock is intensely fractured, commonly brecciated, and cemented with either silica or calcite. Slickensides and mullion display various orientations within the zone and on individual outcrops. The dominant movement, however, appears to be vertical with no evidence for significant strike-slip movements. Pleistocene deposits do not exhibit offsets across the fault zone, indicating that no tectonic activity has occurred since the beginning of that epoch. The trend of the fault zone changes abruptly from east-west in southern Gallatin and easternmost Saline Counties to south-southwest in southern Saline and northeastern Pope Counties, where it joins the Fluorspar area fault complex. Here the zone widens and develops a braided pattern as the amount of displacement along individual faults decreases. The Shawneetown fault zone and Flourspar area fault complex in part are younger than the Cottage Grove fault system to the northwest and the Wabash Valley fault system to the north. The hope of finding structural traps near the junctions of the fuel systems has spurred recent oil exploration in the area.

Lumm, D.K.; Nelson, W.J.

1983-09-01T23:59:59.000Z

4

Development of Hydrologic Characterization Technology of Fault Zones  

E-Print Network (OSTI)

one example being Dixie Valley, Nevada, an active normalrock at various sites: Dixie Valley, Nevada; Wasatch, Utah;20 m in parts of the Dixie Valley and Wasatch fault zones.

Karasaki, Kenzi

2009-01-01T23:59:59.000Z

5

Stress and fault rock controls on fault zone hydrology, Coso geothermal  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon » Stress and fault rock controls on fault zone hydrology, Coso geothermal field, CA Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Conference Proceedings: Stress and fault rock controls on fault zone hydrology, Coso geothermal field, CA Details Activities (1) Areas (1) Regions (0) Abstract: In crystalline rock of the Coso Geothermal Field, CA, fractures are the primary source of permeability. At reservoir depths, borehole image, temperature, and mud logs indicate fluid flow is concentrated in extensively fractured damage zones of large faults well-oriented for slip.

6

Development of Characterization Technology for Fault Zone Hydrology  

SciTech Connect

Several deep trenches were cut, and a number of geophysical surveys were conducted across the Wildcat Fault in the hills east of Berkeley, California. The Wildcat Fault is believed to be a strike-slip fault and a member of the Hayward Fault System, with over 10 km of displacement. So far, three boreholes of ~;; 150m deep have been core-drilled and borehole geophysical logs were conducted. The rocks are extensively sheared and fractured; gouges were observed at several depths and a thick cataclasitic zone was also observed. While confirming some earlier, published conclusions from shallow observations about Wildcat, some unexpected findings were encountered. Preliminary analysis indicates that Wildcat near the field site consists of multiple faults. The hydraulic test data suggest the dual properties of the hydrologic structure of the fault zone. A fourth borehole is planned to penetrate the main fault believed to lie in-between the holes. The main philosophy behind our approach for the hydrologic characterization of such a complex fractured system is to let the system take its own average and monitor a long term behavior instead of collecting a multitude of data at small length and time scales, or at a discrete fracture scale and to ?up-scale,? which is extremely tenuous.

Karasaki, Kenzi; Onishi, Tiemi; Gasperikova, Erika; Goto, Junichi; Tsuchi, Hiroyuki; Miwa, Tadashi; Ueta, Keiichi; Kiho, Kenzo; MIyakawa, Kimio

2010-08-06T23:59:59.000Z

7

Locating an active fault zone in Coso geothermal field by analyzing seismic  

Open Energy Info (EERE)

Locating an active fault zone in Coso geothermal field by analyzing seismic Locating an active fault zone in Coso geothermal field by analyzing seismic guided waves from microearthquake data Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Conference Proceedings: Locating an active fault zone in Coso geothermal field by analyzing seismic guided waves from microearthquake data Details Activities (1) Areas (1) Regions (0) Abstract: Active fault systems usually provide high-permeability channels for hydrothermal outflow in geothermal fields. Locating such fault systems is of a vital importance to plan geothermal production and injection drilling, since an active fault zone often acts as a fracture-extensive low-velocity wave guide to seismic waves. We have located an active fault zone in the Coso geothermal field, California, by identifying and analyzing

8

Modeling fault-zone guided waves of microearthquakes in a geothermal  

Open Energy Info (EERE)

fault-zone guided waves of microearthquakes in a geothermal fault-zone guided waves of microearthquakes in a geothermal reservoir Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: Modeling fault-zone guided waves of microearthquakes in a geothermal reservoir Details Activities (1) Areas (1) Regions (0) Abstract: Fault-zone guided waves have been identified in microearthquake seismograms recorded at the Coso Geothermal Field, California. The observed guided waves have particle motions and propagation group velocities similar to Rayleigh wave modes. A numerical method has been employed to simulate the guided-wave propagation through the fault zone. By comparing observed and synthetic waveforms the fault-zone width and its P- and S-wave velocity structure have been estimated. It is suggested here that the identification

9

Evolution of the Sorong fault zone, northeast Indonesia  

SciTech Connect

The Sorong fault zone (SFZ) of northeast Indonesia is a broad zone of inferred left-lateral shear at the triple junction of the Indo-Australian, Eurasian, and Pacific plates. It is widely believed that fragments of the northern Australian continental margin in New Guinea are being detached and translated westward in this shear zone until they collide with the eastern margin of Eurasia (Sundaland) in the region of Sulawesi Island. However, the details of terrane translation, amalgamation, and docking remain poorly documented. In particular, the timing of events is very poorly constrained, with estimates for the commencement of the SFZ ranging from early Miocene or older to Pleistocene. Recent investigations of the SFZ and the adjacent regions of Sulawesi and Irian Jaya (Indonesian New Guinea), including new fieldwork in several of the SFZ island-terranes (Waigeo, Halmahera, Bacon, Obi, and Sula), suggest a less mobilist interpretation of the region than previous reconstructions. In general, the closest interisland geological correlations are between the geographically closest islands. This would seem to favor rather conservative reconstructions, and a new interpretation of the region based on this tenet is proposed. Although arc-continent collision commented in New Guinea during the mid-Oligocene and only slightly later in Sulaswesi, the SFZ did not begin to develop in its present form before the late Miocene.

Charlton, T.R.

1991-03-01T23:59:59.000Z

10

Development of Hydrologic Characterization Technology of Fault Zones  

E-Print Network (OSTI)

pathways in the Monterey Formation, California: Americanalong faults in the Monterey Formation, coastal California.

Karasaki, Kenzi

2009-01-01T23:59:59.000Z

11

Thermal Waters Along The Konocti Bay Fault Zone, Lake County, California- A  

Open Energy Info (EERE)

Waters Along The Konocti Bay Fault Zone, Lake County, California- A Waters Along The Konocti Bay Fault Zone, Lake County, California- A Re-Evaluation Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: Thermal Waters Along The Konocti Bay Fault Zone, Lake County, California- A Re-Evaluation Details Activities (3) Areas (1) Regions (0) Abstract: The Konocti Bay fault zone (KBFZ), initially regarded by some as a promising target for liquid-dominated geothermal systems, has been a disappointment. At least five exploratory wells were drilled in the vicinity of the KBFZ, but none were successful. Although the Na-K-Ca and Na-Li geothermometers indicate that the thermal waters discharging in the vicinity of Howard and Seigler Springs may have equilibrated at temperatures greater than 200°C, the spring temperatures and fluid

12

Pull-Apart in Strike-Slip Fault Zone | Open Energy Information  

Open Energy Info (EERE)

Pull-Apart in Strike-Slip Fault Zone Pull-Apart in Strike-Slip Fault Zone Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Pull-Apart in Strike-Slip Fault Zone Dictionary.png Pull-Apart in Strike-Slip Fault Zone: No definition has been provided for this term. Add a Definition Pull-aparts form in strike-slip fault zones. Arrows indicate direction of slip. (reference: http://myweb.cwpost.liu.edu/vdivener/notes/cont_transform.htm) Faulds uses this term as a structural control found in the Basin and Range province of the US. 4% of all Great Basin geothermal systems are located in pull-aparts but are more abundant within or along the margins of the Walker Lane. (reference: http://www.atlasgeoinc.com/wp-content/uploads/GRC2011-Faulds.pdf). Retrieved from "http://en.openei.org/w/index.php?title=Pull-Apart_in_Strike-Slip_Fault_Zone&oldid=599541"

13

Fault-zone seals in siliciclastic strata of the Columbus Basin, offshore Trinidad  

Science Conference Proceedings (OSTI)

This study combines observations from outcrop and drill core with an analysis of the hydrocarbon distribution in two mature oil and gas fields to document the factors controlling the existence of fault seals in the Tertiary sandstone-shale sequence of the Columbus Basin. Juxtaposition of reservoir sandstones against shale intervals across normal faults cannot explain the oil and gas distribution in this area, indicating that fault zones serve as the lateral seals for these hydrocarbon accumulations. The fault-zone seals for the largest hydrocarbon columns (50-200 m) consist of shale smears formed by ductile deformation of shale beds during fault slip. Fault segments that do not meet the criteria for development of a shale smear appear to be transmissible or can seal only small columns (shale smears are discontinuous, such as where a sandstone body is partially juxtaposed against itself, column heights are cross-fault spill-point limited and can be analyzed using fault-plane sections combined with mapping of shale-smear continuity. These traps are likely to preferentially spill high-density hydrocarbons once trap capacity is reached. In contrast, traps bounded by spatially continuous shale smears probably leak through the pore network of the fault-zone material at the top of the trap, thus favoring preferential movement of low-density hydrocarbons in a two-phase system. Hydrocarbon migration through stratigraphic sections containing fault-sealed traps of these two types may result in geochemical fractionation and phase segregation, both of which are observed in the Columbus Basin fields.

Gibson, R.G. [Amoco Production Research, Tulsa, OK (United States)

1994-09-01T23:59:59.000Z

14

Development of Hydrologic Characterization Technology of Fault Zones -- Phase I, 2nd Report  

Science Conference Proceedings (OSTI)

This is the year-end report of the 2nd year of the NUMO-LBNL collaborative project: Development of Hydrologic Characterization Technology of Fault Zones under NUMO-DOE/LBNL collaboration agreement, the task description of which can be found in the Appendix 3. Literature survey of published information on the relationship between geologic and hydrologic characteristics of faults was conducted. The survey concluded that it may be possible to classify faults by indicators based on various geometric and geologic attributes that may indirectly relate to the hydrologic property of faults. Analysis of existing information on the Wildcat Fault and its surrounding geology was performed. The Wildcat Fault is thought to be a strike-slip fault with a thrust component that runs along the eastern boundary of the Lawrence Berkeley National Laboratory. It is believed to be part of the Hayward Fault system but is considered inactive. Three trenches were excavated at carefully selected locations mainly based on the information from the past investigative work inside the LBNL property. At least one fault was encountered in all three trenches. Detailed trench mapping was conducted by CRIEPI (Central Research Institute for Electric Power Industries) and LBNL scientists. Some intriguing and puzzling discoveries were made that may contradict with the published work in the past. Predictions are made regarding the hydrologic property of the Wildcat Fault based on the analysis of fault structure. Preliminary conceptual models of the Wildcat Fault were proposed. The Wildcat Fault appears to have multiple splays and some low angled faults may be part of the flower structure. In parallel, surface geophysical investigations were conducted using electrical resistivity survey and seismic reflection profiling along three lines on the north and south of the LBNL site. Because of the steep terrain, it was difficult to find optimum locations for survey lines as it is desirable for them to be as straight as possible. One interpretation suggests that the Wildcat Fault is westerly dipping. This could imply that the Wildcat Fault may merge with the Hayward Fault at depth. However, due to the complex geology of the Berkeley Hills, multiple interpretations of the geophysical surveys are possible. iv An effort to construct a 3D GIS model is under way. The model will be used not so much for visualization of the existing data because only surface data are available thus far, but to conduct investigation of possible abutment relations of the buried formations offset by the fault. A 3D model would be useful to conduct 'what if' scenario testing to aid the selection of borehole drilling locations and configurations. Based on the information available thus far, a preliminary plan for borehole drilling is outlined. The basic strategy is to first drill boreholes on both sides of the fault without penetrating it. Borehole tests will be conducted in these boreholes to estimate the property of the fault. Possibly a slanted borehole will be drilled later to intersect the fault to confirm the findings from the boreholes that do not intersect the fault. Finally, the lessons learned from conducting the trenching and geophysical surveys are listed. It is believed that these lessons will be invaluable information for NUMO when it conducts preliminary investigations at yet-to-be selected candidate sites in Japan.

Karasaki, Kenzi; Onishi, Tiemi; Black, Bill; Biraud, Sebastien

2009-03-31T23:59:59.000Z

15

Trapping capacity of fault zones, downdip Yegua Formation, Texas Gulf Coast basin  

E-Print Network (OSTI)

The homogenization of sediment from shearing forms traps in both the hanging wall and footwall due to capillary pressure differences. The sheared zone associated with large faults can form traps. Sheared zones associated with small faults can compartmentalize reservoirs leading to unreliable estimates of reserves. Measured values of capillary pressure were compared with estimated capillary pressure values from four correlation methods. Based on comparison of estimated pressure with measured pressure, Pittman's method gave the most reliable results for predicting capillary pressure and therefore the height of the oil column. However, all methods for predicting capillary pressure worked well for samples with porosities above 20% and permeabilities above 100 md. Hydrocarbon column heights were then determined from the capillary pressure values. The large sheared zone of the Cities Service Dincans1 (CD1) well, Toro Grande field, Jackson County, has a predicted trapping capacity of up to 1,961 ft of oil at 10,000 ft depth and 35% saturation of oil. Shearing is mostly at the hand specimen scale in the General Crude Kirby Lumber 2 (GCK2) well, East Sour Lake field, Hardin County, which has a maximum trapping capacity of 111 ft. From this study, it is then concluded that a homogenized sheared zone, formed from ductile deformation of sand and shale layers can form a trap to hydrocarbons. Sheared zones may be thick zones, on the order of feet, or smaller zones at microscopic or hand specimen scale. The larger the sheared zone is, the greater the trapping capacity of the fault.

Hintz, Jena Christine

2001-01-01T23:59:59.000Z

16

Locating an active fault zone in Coso geothermal field by analyzing seismic guided waves from microearthquake data  

DOE Green Energy (OSTI)

Active fault systems usually provide high-permeability channels for hydrothermal outflow in geothermal fields. Locating such fault systems is of a vital importance to plan geothermal production and injection drilling, since an active fault zone often acts as a fracture-extensive low-velocity wave guide to seismic waves. We have located an active fault zone in the Coso geothermal field, California, by identifying and analyzing a fault-zone trapped Rayleigh-type guided wave from microearthquake data. The wavelet transform is employed to characterize guided-wave's velocity-frequency dispersion, and numerical methods are used to simulate the guided-wave propagation. The modeling calculation suggests that the fault zone is {approx} 200m wide, and has a P wave velocity of 4.80 km/s and a S wave velocity of 3.00 km/s, which is sandwiched between two half spaces with relatively higher velocities (P wave velocity 5.60 km/s, and S wave velocity 3.20 km/s). zones having vertical or nearly vertical dipping fault planes.

SGP-TR-150-16

1995-01-26T23:59:59.000Z

17

Creating infrastructure for seismic microzonation by Geographical Information Systems (GIS): A case study in the North Anatolian Fault Zone (NAFZ)  

Science Conference Proceedings (OSTI)

Although there are many studies for seismic microzonation in the literature, these studies have not covered the whole seismic microzonation processes. Moreover, they have not sufficiently focused on the important subjects, such as significance and use ... Keywords: GIS, North Anatolian Fault Zone, Photogrammetry, Seismic microzonation, Spatiotemporal analysis

T. Turk; U. GM?Ay; O. Tatar

2012-06-01T23:59:59.000Z

18

The effect of fractures, faults, and sheared shale zones on the hydrology of Bear Creek Burial Grounds A-South, Oak Ridge, Tennessee  

E-Print Network (OSTI)

Previous hydrologic models of flow in Bear Creek Valley have presented lateral flow as occurring through the Nolichucky Shale in parallel to strike fractures within thin carbonate beds; the effects of faults were not considered. This study presents a ground water flow model that incorporates lateral flow through parallel-to-strike fractures and thrust faults, and perpendicular-to-strike cross valley strike-slip faults. These latter cross-valley structures cause flow to be diverted to other strikeparallel zones of enhanced permeability towards the south side of the valley. Using core, geophysical and hydrologic data from five boreholes in the Bear Creek Burial Grounds three types of potential fluid-flow conduits were identified: fractures, faults, and shale shear zones. Open fractures decrease in abundance with depth and tend to occur most frequently in oolitic limestone beds relative to other carbonate lithologies. Fractures below 1 00 ft BGS in the Nolichucky Shale and below 250 ft in the Maynardville Limestone do not appear to be caused by dissolution; instead, they appear to be the result of a change in the local stress field due to erosion effects. Faults, both cross-valley and thrust faults, and sheared shale zones are interpreted to disrupt the lateral continuity of the bedding and increase the rock-mass permeability of the Nolichucky Shale, permitting ground water to flow these structural zones. This study provided opportunity to interpret DNAPL migration patterns from Burial Ground A-South. DNAPL migration parallel to the valley's axis is affected by parallel-to-strike fractures and thrust faults, and its lateral migration perpendicular to strike is influenced by cross valley strike-slip faults and decreasing collect at depth because of decreasing fracture occurrence and reduced permeability and then migrate laterally along the cross valley strike-slip faults until it encounters and enters a zone of higher permeability parallel to strike.

Hollon, Dwight Mitchell

1997-01-01T23:59:59.000Z

19

Association of coal metamorphism and hydrothermal mineralization in Rough Creek fault zone and Fluorspar District, Western Kentucky  

SciTech Connect

The ambient coal rank (metamorphism) of the Carboniferous coals in the Western Kentucky coalfield ranges from high volatile A bituminous (vitrinite maximum reflectance up to 0.75% R/sub max/) in the Webster syncline (Webster and southern Union Counties) to high volatile C bituminous (0.45 to 0.60% R/sub max/) over most of the remainder of the area. Anomalous patterns of metamorphism, however, have been noted in coals recovered from cores and mines in fault blocks of the Rough Creek fault zone and Fluorspar District. Coals in Gil-30 borehole (Rough Creek faults, Bordley Quadrangle, Union County) vary with no regard for vertical position, from high volatile C(0.55% R/sub max/) to high volatile A (0.89%R/sub max) bituminous. Examination of the upper Sturgis Formation (Missourian/Virgilian) coals revealed that the higher rank (generally above 0.75% R/sub max/) coals had vein mineral assemblages of sphalerite, twinned calcite, and ferroan dolomite. Lower rank coals had only untwinned calcite. Several sites in Webster County contain various coals (Well (No. 8) to Coiltwon (No. 14)) with vitrinite reflectances up to 0.83% R/sub max/ and associated sphalerite mineralization. Mississippian and Lower Pennsylvanian (Caseyville Formation Gentry coal) coals in the mineralized Fluorspar District have ranks to nearly medium volatile bituminous (1.03% R/sub max/). The regional rank trend exhibited by the fualt zones is generally higher rank than the surrounding areas. Sphalerite mineralization in itself is not unique within Illinois basin coals, but if it was partly responsible for the metamorphism of these coals, then the fluid temperature must have been higher within the above mentioned fault complexes.

Hower, J.C.; Fiene, F.L.; Trinkle, E.J.

1983-09-01T23:59:59.000Z

20

Development of a Hydrologic Characterization Technology for Fault Zones Phase II 2nd Report  

E-Print Network (OSTI)

Usually, the drilling fluids and mud are temporarily storedbeen coated with thick drilling fluid, with added polymerdrilling in WF-4 at ~183 m, the zones in WF-1 responded to the lowering and rising of the fluid

Karasaki, Kenzi

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "madrid fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Development of a Hydrologic Characterization Technology for Fault Zones Phase II 2nd Report  

E-Print Network (OSTI)

4-28 4.6.1 Claremont Fm. chert and shalecontact between chert and shale of the Claremont Fm. andzone and strips of black shale. A second zone with mixtures

Karasaki, Kenzi

2013-01-01T23:59:59.000Z

22

Magnesium Workshop Madrid 2013: Home Page  

Science Conference Proceedings (OSTI)

Magnesium Workshop Madrid 2013. An International Workshop on Processing- Microstructure-Mechanical Property of Magnesium Alloys May 21-24, 2013...

23

Earthquake source parameters and fault kinematics in the Eastern California Shear Zone  

E-Print Network (OSTI)

Based on waveform data from a profile of aftershocks following the north-south trace of the June 28, 1992 Landers rupture across the Mojave desert, we construct a new velocity model for the Mojave region which features a thin, slow crust. Using this model, we obtain source parameters, including depth and duration, for each of the aftershocks in the profile, and in addition, any significant (M>3.7) Joshua Tree--Landers aftershock between April, 1992 and October, 1994 for which coherent TERRAscope data were available. In all, we determine source parameters and stress-drops for 45 significant (M_w > 4) earthquakes associated with the Joshua Tree and Landers sequences, using a waveform grid-search algorithm. Stress drops for these earthquakes appear to vary systematically with location, with respect to previous seismic activity, proximity to previous rupture (i.e., with respect to the Landers rupture), and with tectonic province. In general, for areas north of the Pinto Mountain fault, stress-drops of aftershocks...

Jones, L E; Jones, Laura E.; Helmberger, Donald V.

1998-01-01T23:59:59.000Z

24

Application of Control Charts for Detecting Faults in Variable ...  

Science Conference Proceedings (OSTI)

... where Tzone = zone temperature, CSP = cooling setpoint ... Fault Implementation and Impact To test ... fault imple- mentations and impacts are provided ...

25

Polytechnic University of Madrid | Open Energy Information  

Open Energy Info (EERE)

Polytechnic University of Madrid Polytechnic University of Madrid Jump to: navigation, search Name Polytechnic University of Madrid Place Madrid, Spain Sector Solar Product University piloting a 2.7MW solar concentrator photovoltaic plant. Coordinates 40.4203°, -3.705774° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":40.4203,"lon":-3.705774,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

26

Accommodation Zone | Open Energy Information  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon » Accommodation Zone Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Accommodation Zone Dictionary.png Accommodation Zone: Accommodation zones occur at fault intersections consisting of belts of interlocking, oppositely dipping normal faults. Multiple subsurface fault intersections in these zones are a favorable host for geothermal activity. Other definitions:Wikipedia Reegle Controlling Structures List of controlling structures typically associated with geothermal systems: Major Normal Fault Termination of a Major Normal Fault Stepover or Relay Ramp in Normal Fault Zones

27

Major Normal Fault | Open Energy Information  

Open Energy Info (EERE)

Major Normal Fault Major Normal Fault Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Major Normal Fault Dictionary.png Major Normal Fault: Normal faults are structures in which the hanging wall is down dropped along the fault plane relative to the foot wall. They are the predominant type of structure in extensional tectonic environments, but are commonly encountered in a number of geologic settings. Other definitions:Wikipedia Reegle Controlling Structures List of controlling structures typically associated with geothermal systems: Major Normal Fault Termination of a Major Normal Fault Stepover or Relay Ramp in Normal Fault Zones Apex or Salient of Normal Fault Fault Intersection Accommodation Zone Displacement Transfer Zone Pull-Apart in Strike-Slip Fault Zone

28

Neogene carbonate exploration play concepts for Northern New Guinea: New iteration from field work and seismic stratigraphy along the Northern New Guinea Fault Zone  

Science Conference Proceedings (OSTI)

Recent field reconnaissance, petrography, nanno and foraminifera age determinations, and seismic stratigraphy of the Sepik and Piore subbasins of northern New Guinea reveal the existence of an extensive, tectonically unstable, Miocene-Pliocene carbonate shelf system. These findings represent the first recorded evidence of northern Papuan limestones coeval in age to those of the hydrocarbon productive Salawati Basin of Irian Jaya. Moreover, these observations also demonstrate the significance of episodic activities of the northern New Guinea fault zone upon the changes in carbonate sedimentation and diagenesis. During the Neogene, algal biosparites to foraminiferal biomicrites defined the clean portion of a mixed clastic-carbonate shelf system of the northern New Guinea basin, which began at the central New Guinea cordillera and deepened northward. This shelf was interrupted by coral-coralline algal boundstone fringing- to patch-reef buildups with associated skeletal grainstones. Clean carbonates were spatially and temporally restricted to basement blocks, which episodically underwent uplift while terrigenous dilutes carbonates were more common in adjacently subsiding basement block bathymetric lows. These tectonic expressions were caused by the spatially transient nature of constraining bends of the evolving north New Guinea faults. As shown by seismic stratigraphy, by the late Miocene to the early Pliocene the uplift of the Bewani-Torricelli Mountains sagittally divided the shelf of the northern New Guinea basin into the Ramu-Sepik and the Piore basins. Continued regional sinistral transpression between the Pacific and the New Guinea leading edge of the Indo-Australian plates led to the reverse tilting of the Piore basin, the shallowing of the former distal shelf with concomitant extensive biolithite development (e.g., on subsiding volcanic islands) eventual uplifting of the Oenake Range, and en echelon faulting of the Bewani-Torricelli Mountains.

Pigott, J.D.; Geiger, C. (Univ. of Oklahoma, Norman, OK (United States))

1994-07-01T23:59:59.000Z

29

Fault Intersection | Open Energy Information  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon » Fault Intersection Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Fault Intersection Dictionary.png Fault Intersection: Fault intersections are junctions between normal faults and either transversely oriented strike-slip or oblique-slip faults. Subsurface fluid flow in these areas is enhanced by multiple minor faults that connect the major intersecting structures, forming highly fractured zones or dilational quadrants with increased permeability. Other definitions:Wikipedia Reegle Controlling Structures List of controlling structures typically associated with geothermal

30

Madrid, Alabama: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Madrid, Alabama: Energy Resources Madrid, Alabama: Energy Resources Jump to: navigation, search Equivalent URI DBpedia Coordinates 31.0357372°, -85.3932662° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":31.0357372,"lon":-85.3932662,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

31

DOE Solar Decathlon: Universidad Politcnica de Madrid: Going...  

NLE Websites -- All DOE Office Websites (Extended Search)

Darmstadt Georgia Illinois Kansas Lawrence Madrid Maryland MIT Montral NYIT Penn State Puerto Rico Rolla Santa Clara Texas Texas A&M Quick Links Solar Decathlon Home Solar...

32

DOE Solar Decathlon: Universidad Politcnica de Madrid: Teaching...  

NLE Websites -- All DOE Office Websites (Extended Search)

Cornell Crowder Florida International Madrid Maryland Michigan NYIT Pittsburgh Synergy Puerto Rico RISD Rolla Texas U Mass Dartmouth Virginia Tech Washington Quick Links Solar...

33

Carbon deposition during brittle rock deformation: Changes in electrical properties of fault zones and potential geoelectric phenomena during earthquakes  

Science Conference Proceedings (OSTI)

To investigate potential mechanisms for geoelectric phenomena accompanying earthquakes, we have deformed hollow cylinders of Sioux quartzite to failure in the presence of carbonaceous pore fluids and investigated the resulting changes in electrical conductivity and carbon distribution. Samples were loaded at room temperature or 400 C by a hydrostatic pressure at their outer diameter, increasing pressure at a constant rate to {approx}290 MPa. Pore fluids consisted of pure CO, CO{sub 2}, CH{sub 4} and a 1:1 mixture of CO{sub 2} and CH{sub 4}, each with pore pressures of 2.0 to 4.1 MPa. Failure occurred by the formation of mode II shear fractures transecting the hollow cylinder walls. Radial resistivities of the cylinders fell to 2.9 to 3.1 M{Omega}-m for CO tests and 15.2 to 16.5 M{Omega}-m for CO{sub 2}:CH{sub 4} tests, compared with >23 M{Omega}-m for dry, undeformed cylinders. Carbonaceous fluids had no discernable influence on rock strength. Based on mapping using electron microprobe techniques, carbon occurs preferentially as quasi-continuous films on newly-formed fracture surfaces, but these films are absent from pre-existing surfaces in those same experiments. The observations support the hypothesis that electrical conductivity of rocks is enhanced by the deposition of carbon on fracture surfaces and imply that electrical properties may change in direct response to brittle deformation. They also suggest that the carbon films formed nearly instantaneously as the cracks formed. Carbon film deposition may accompany the development of microfracture arrays prior to and during fault rupture and thus may be capable of explaining precursory and coseismic geoelectric phenomena.

Mathez, E A; Roberts, J J; Duba, A G; Kronenberg, A K; Karner, S L

2008-05-16T23:59:59.000Z

34

Apex or Salient of Normal Fault | Open Energy Information  

Open Energy Info (EERE)

Apex or Salient of Normal Fault Apex or Salient of Normal Fault Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Apex or Salient of Normal Fault Dictionary.png Apex or Salient of Normal Fault: Normal faults may intersect in the subsurface to form a fault apex or salient. Apices or salients of normal faults account for 3% of structural controls in the Great Basin. Other definitions:Wikipedia Reegle Controlling Structures List of controlling structures typically associated with geothermal systems: Major Normal Fault Termination of a Major Normal Fault Stepover or Relay Ramp in Normal Fault Zones Apex or Salient of Normal Fault Fault Intersection Accommodation Zone Displacement Transfer Zone Pull-Apart in Strike-Slip Fault Zone Intrusion Margins and Associated Fractures Stratigraphic Boundaries

35

Hydrothermal brecciation in the Jemez Fault zone, Valles Caldera, New Mexico: Results from CSDP (Continental Scientific Drilling Program) corehole VC-1  

DOE Green Energy (OSTI)

Paleozoic and Precambrian rocks intersected deep in Continental Scientific Drilling Program corehole VC-1, adjacent to the late Cenozoic Valles caldera complex, have been disrupted to form a spectacular breccia sequence. The breccias are of both tectonic and hydrothermal origin, and probably formed in the Jemez fault zone, a major regional structure with only normal displacement since mid-Miocene. Tectonic breccias are contorted, crushed, sheared, and granulated; slickensides are commmon. Hydrothermal breccias, by contrast, lack these frictional textures, but arej commonly characterized by fluidized matrix foliation and prominent clast rounding. Fluid inclusions in the hydrothermal breccias are dominantly two-phase, liquid-rich at room temperature, principally secondary, and form two distinctly different compositional groups. Older inclusions, unrelated to brecciation, are highly saline and homogenize to the liquid phase in the temperature range 189 to 246/sup 0/C. Younger inclusions, in part of interbreccia origin, are low-salinity and homogenize (also to liquid) in the range 230 to 283/sup 0/C. Vapor-rich inclusions locally trapped along with these dilute liquid-rich inclusions document periodic boiling. These fluid-inclusion data, together with alteration assemblages and textures as well as the local geologic history, have been combined to model hydrothermal brecciation at the VC-1 site.

Hulen, J.B.; Nielson, D.L.

1987-06-01T23:59:59.000Z

36

Quaternary faulting of Deschutes County, Oregon.  

E-Print Network (OSTI)

??Sixty-one normal faults were identified in a 53-kilometer long by 21-kilometer wide northwest-trending zone in central and northern Deschutes County, Oregon. The faults are within (more)

Wellik, John M.

2008-01-01T23:59:59.000Z

37

Displacement Transfer Zone | Open Energy Information  

Open Energy Info (EERE)

Displacement Transfer Zone Displacement Transfer Zone Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Displacement Transfer Zone Dictionary.png Displacement Transfer Zone: Displacement transfer zones facilitate the transfer of strain between normal and strike-slip faults. Intersections between strike-slip faults in the Walker Lane and N- to NNE-striking normal faults commonly host geothermal systems, focused along the normal faults proximal to their dilational intersections with nearby strike-slip faults. Other definitions:Wikipedia Reegle Controlling Structures List of controlling structures typically associated with geothermal systems: Major Normal Fault Termination of a Major Normal Fault Stepover or Relay Ramp in Normal Fault Zones Apex or Salient of Normal Fault

38

Internal structure of the Kern Canyon Fault, California: a deeply exhumed strike-slip fault  

E-Print Network (OSTI)

Deformation and mineral alteration adjacent to a 2 km long segment of the Kern Canyon fault near Lake Isabella, California are studied to characterize the internal structure of the fault zone and to understand the development of fault structure and constitution and the mechanical and chemical processes responsible for them. The 140 km long Kern Canyon fault (KCF) is a fault of 15 km right-lateral separation exhumed from seismogenic depth that cuts batholithic and metamorphic rocks of the southern Sierra Nevada. The fault consists of at least three distinct phases: an early phase of lower-greenschist-grade ductile shear with an S-C' phyllonite, a subsequent, dominant phase of brittle faulting characterized by a through-going zone of cataclastic rock, and a late stage of minor faulting along discontinuous, thin, hematitic gouge zones. The S-C' fabric and subsidiary fault-slip data indicate that both the phyllonitic and cataclastic zones are approximately vertical and strike-slip; slip lineations within the hematitic gouge suggest oblique-slip. The phyllonite zone trends N20-40E and accommodated ~175 m of separation. The cataclastic zone cuts the phyllonite, trends N21E, and consists of foliated and non-foliated cataclasites; it accommodates the majority of displacement along the fault. Abundant veins and fluid-assisted alteration in the rock surrounding the fault zone attest to the presence of fluids of evolving chemistry during both ductile and brittle faulting. Mass balance calculations indicate quartz loss during phyllonite faulting and imply that the fault system was open and experienced a negative change in volume during phyllonite faulting. Mesoscale and microscale fracture intensities decrease with log distance from the foliated cataclasites and approach a relatively low level at approximately 500 m. The internal structure of the Kern Canyon fault is similar to other large displacement faults in that it consists of a broad zone of fractured and altered rock and a narrow zone of intense cataclasis.

Neal, Leslie Ann

2002-01-01T23:59:59.000Z

39

Madrid, Spain: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

form form View source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit with form History Facebook icon Twitter icon » Madrid, Spain: Energy Resources Jump to: navigation, search Equivalent URI DBpedia GeoNames ID 3117735 Coordinates 40.4165°, -3.70256° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":40.4165,"lon":-3.70256,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

40

City of New Madrid, Missouri (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

New Madrid New Madrid Place Missouri Utility Id 13470 Utility Location Yes Ownership M NERC Location SERC NERC SERC Yes RTO SPP Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Commercial NMCC Industrial Industrial Residential Residential Senior Citizens Discount Residential Average Rates Residential: $0.0604/kWh Commercial: $0.0689/kWh Industrial: $0.0648/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=City_of_New_Madrid,_Missouri_(Utility_Company)&oldid=41001

Note: This page contains sample records for the topic "madrid fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Regional seismic reflection line, southern Illinois Basin, provides new data on Cambrian rift geometry, Hicks Dome genesis, and the Fluorspar Area Fault Complex  

SciTech Connect

Detailed studies of the subsurface structure of the Cambrian Reelfoot rift (RFR) in the Midwestern US provide important insights into continental rifting processes and into the structural fabric of a zone of modern intracratonic seismicity (New Madrid zone). High-quality oil industry seismic reflection data show that in the area of transition between the RFR and the Rough Creek Graben (RCG) the geometry of the Cambrian rift system is that of a half-graben that thickens to the southeast. This contrasts with the northward-thickening half-graben observed to the east in the RCG and with the more symmetric graben to the south in the RFR. An 82.8-km segment of a northwest-southeast seismic reflection profile in southeastern Illinois and western Kentucky shows that near Hicks Dome, Illinois, Middle and Lower Cambrian syn-rift sedimentary rocks occupy about 0.35 s (two-way travel time) on the seismic reflection section (corresponding to a thickness of about 970 m). This stratigraphic interval occupies about 0.45 s (1,250 m) near the Ohio river and is thickest against the Tabb Fault System (TFS) in Kentucky, where it occupies 0.7 s (1,940 m). The seismic data show that in this part of the Cambrian rift the master fault was part of the TFS and that normal displacement on the TFS continued through middle Paleozoic time. The seismic data also provide new information on the late Paleozoic development of Hicks-Dome and the surrounding Fluorspar Area Fault Complex (FAFC) in southeastern Illinois and western Kentucky. A series of grabens and horsts in the FAFC document a late Paleozoic reactivation of the RFR. Comparison of the reflection data with surface mineralization patterns shows that in most cases mineralized graben-bounding faults clearly cut basement or are splays from faults that cut basement.

Potter, C.J.; Goldhaber, M.B.; Taylor, C.D. (U.S. Geological Survey, Denver, CO (United States)); Heigold, P.C. (Illinois State Geological Survey, Champaign, IL (United States))

1992-01-01T23:59:59.000Z

42

Fault finder  

DOE Patents (OSTI)

A fault finder for locating faults along a high voltage electrical transmission line. Real time monitoring of background noise and improved filtering of input signals is used to identify the occurrence of a fault. A fault is detected at both a master and remote unit spaced along the line. A master clock synchronizes operation of a similar clock at the remote unit. Both units include modulator and demodulator circuits for transmission of clock signals and data. All data is received at the master unit for processing to determine an accurate fault distance calculation.

Bunch, Richard H. (1614 NW. 106th St., Vancouver, WA 98665)

1986-01-01T23:59:59.000Z

43

New Madrid, Missouri: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

(Redirected from New Madrid, MO) (Redirected from New Madrid, MO) Jump to: navigation, search Equivalent URI DBpedia Coordinates 36.5864488°, -89.5278547° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":36.5864488,"lon":-89.5278547,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

44

MHK Projects/New Madrid Bend Project | Open Energy Information  

Open Energy Info (EERE)

Madrid Bend Project Madrid Bend Project < MHK Projects Jump to: navigation, search << Return to the MHK database homepage Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":5,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"500px","height":"350px","centre":false,"title":"","label":"","icon":"File:Aquamarine-marker.png","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":36.5515,"lon":-89.4613,"alt":0,"address":"","icon":"http:\/\/prod-http-80-800498448.us-east-1.elb.amazonaws.com\/w\/images\/7\/74\/Aquamarine-marker.png","group":"","inlineLabel":"","visitedicon":""}]}

45

New Madrid and Wabash Valley Seismic Study: Assessing the Impacts on Natural Gas  

E-Print Network (OSTI)

New Madrid and Wabash Valley Seismic Study: Assessing the Impacts on Natural Gas Transmission.S. Natural Gas Pipeline System Key Findings ­ New Madrid and Wabash Events Summary of Damages and Estimated Restoration Time Seismic Performance of Underground Storage Facilities Conclusions ­ Natural Gas Pipeline

Kemner, Ken

46

Stress and fault rock controls on fault zone hydrology, Coso...  

Open Energy Info (EERE)

often function as hydrologic barriers separating regions of distinct fluid inclusion chemistry and temperature gradient. Distributed fracture networks play only a minor role in...

47

Observations on Faults and Associated Permeability Structures in Hydrogeologic Units at the Nevada Test Site  

SciTech Connect

Observational data on Nevada Test Site (NTS) faults were gathered from a variety of sources, including surface and tunnel exposures, core samples, geophysical logs, and down-hole cameras. These data show that NTS fault characteristics and fault zone permeability structures are similar to those of faults studied in other regions. Faults at the NTS form complex and heterogeneous fault zones with flow properties that vary in both space and time. Flow property variability within fault zones can be broken down into four major components that allow for the development of a simplified, first approximation model of NTS fault zones. This conceptual model can be used as a general guide during development and evaluation of groundwater flow and contaminate transport models at the NTS.

Prothro, Lance B.; Drellack, Sigmund L.; Haugstad, Dawn N.; Huckins-Gang, Heather E.; Townsend, Margaret J.

2009-03-30T23:59:59.000Z

48

Analysis of the growth of strike-slip faults using effective medium theory  

SciTech Connect

Increases in the dimensions of strike-slip faults including fault length, thickness of fault rock and the surrounding damage zone collectively provide quantitative definition of fault growth and are commonly measured in terms of the maximum fault slip. The field observations indicate that a common mechanism for fault growth in the brittle upper crust is fault lengthening by linkage and coalescence of neighboring fault segments or strands, and fault rock-zone widening into highly fractured inner damage zone via cataclastic deformation. The most important underlying mechanical reason in both cases is prior weakening of the rocks surrounding a fault's core and between neighboring fault segments by faulting-related fractures. In this paper, using field observations together with effective medium models, we analyze the reduction in the effective elastic properties of rock in terms of density of the fault-related brittle fractures and fracture intersection angles controlled primarily by the splay angles. Fracture densities or equivalent fracture spacing values corresponding to the vanishing Young's, shear, and quasi-pure shear moduli were obtained by extrapolation from the calculated range of these parameters. The fracture densities or the equivalent spacing values obtained using this method compare well with the field data measured along scan lines across the faults in the study area. These findings should be helpful for a better understanding of the fracture density/spacing distribution around faults and the transition from discrete fracturing to cataclastic deformation associated with fault growth and the related instabilities.

Aydin, A.; Berryman, J.G.

2009-10-15T23:59:59.000Z

49

Definition: Displacement Transfer Zone | Open Energy Information  

Open Energy Info (EERE)

Definition Definition Edit with form History Facebook icon Twitter icon » Definition: Displacement Transfer Zone Jump to: navigation, search Dictionary.png Displacement Transfer Zone Displacement transfer zones facilitate the transfer of strain between normal and strike-slip faults. Intersections between strike-slip faults in the Walker Lane and N- to NNE-striking normal faults commonly host geothermal systems, focused along the normal faults proximal to their dilational intersections with nearby strike-slip faults.[2] View on Wikipedia Wikipedia Definition References ↑ James E. Faulds,Nicholas H. Hinz,Mark F. Coolbaugh,Patricia H. Cashman,Christopher Kratt,Gregory Dering,Joel Edwards,Brett Mayhew,Holly McLachlan. 2011. Assessment of Favorable Structural Settings of Geothermal

50

Fault Mapping At Raft River Geothermal Area (1993) | Open Energy  

Open Energy Info (EERE)

Fault Mapping At Raft River Geothermal Area (1993) Fault Mapping At Raft River Geothermal Area (1993) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Fault Mapping At Raft River Geothermal Area (1993) Exploration Activity Details Location Raft River Geothermal Area Exploration Technique Fault Mapping Activity Date 1993 Usefulness useful DOE-funding Unknown Exploration Basis Geologic mapping, strain and kinematic analysis Notes The mountains expose a detachment fault that separates a hanging wall of Paleozoic rocks from Proterozoic and Archean rocks of the footwall. Beneath the detachment lies a 100 to 300m-thick top-to-the-east extensional shear zone. Geologic mapping, strain and kinematic analysis, and 40Ar/39Ar thermochronology suggest that the shear zone and detachment fault had an

51

Dating of major normal fault systems using thermochronology-...  

Open Energy Info (EERE)

River detachment fault and shear zone by study of spatial gradients in 40Ar39 A and fission track cooling ages of footwall rocks and cooling histories and by comparison of...

52

Upper crustal faulting in an obliquely extending orogen, structural control  

Open Energy Info (EERE)

faulting in an obliquely extending orogen, structural control faulting in an obliquely extending orogen, structural control on permeability and production in the Coso Geothermal Field, eastern California Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Conference Proceedings: Upper crustal faulting in an obliquely extending orogen, structural control on permeability and production in the Coso Geothermal Field, eastern California Details Activities (1) Areas (1) Regions (0) Abstract: New multifold seismic reflection data from the Coso geothermal field in the central Coso Range, eastern California, image brittle faults and other structures in a zone of localized crustal extension between two major strike-slip faults. The Coso Wash fault, a Quaternary-active normal fault that is a locus of surface geothermal activity, is well-imaged as a

53

Definition: Accommodation Zone | Open Energy Information  

Open Energy Info (EERE)

Definition Definition Edit with form History Facebook icon Twitter icon » Definition: Accommodation Zone Jump to: navigation, search Dictionary.png Accommodation Zone Accommodation zones occur at fault intersections consisting of belts of interlocking, oppositely dipping normal faults. Multiple subsurface fault intersections in these zones are a favorable host for geothermal activity.[2] View on Wikipedia Wikipedia Definition References ↑ James E. Faulds,Nicholas H. Hinz,Mark F. Coolbaugh,Patricia H. Cashman,Christopher Kratt,Gregory Dering,Joel Edwards,Brett Mayhew,Holly McLachlan. 2011. Assessment of Favorable Structural Settings of Geothermal Systems in the Great Basin, Western USA. In: Transactions. GRC Anual Meeting; 2011/10/23; San Diego, CA. Davis, CA: Geothermal Resources

54

Timing of late Quaternary faulting in the 1954 Dixie Valley earthquake area, central Nevada  

Science Conference Proceedings (OSTI)

The 1954 Dixie Valley earthquake (M 6.9) in central Nevada produced about 3 m of total vertical displacement distributed across two principal fault zones along the east flank of the Stillwater Range. Most of the 1954 displacement was along the range-front fault with minor amounts on the piedmont fault zone, in contrast to an earlier Holocene displacement that was restricted to the piedmont fault. Detailed chronostratigraphic, exploratory drilling, and trenching studies indicate that faulting events have migrated back and forth between the range-front and piedmont fault zones in the late Quaternary. Prior to the 1954 earthquake, the range-front fault last ruptured in the late Pleistocene, during a large-magnitude event here called the IXL event. The northern half of the piedmont fault zone last ruptured between 1.5 and 6.8 ka during a large-magnitude event here called the Bend event. On the basis of 6 m total slip since the deposition of shoreline gravels at {approximately} 12 ka, the estimated Holocene vertical-slip rate is 0.5 mm/yr for the Dixie Valley rupture zone. Overlapping and migratory patterns of late Quaternary faulting indicate that the Dixie Valley zone does not fit a simple segmentation model.

Bell, J.W. (Univ. of Nevada, Reno (USA)); Katzer, T. (Las Vegas Valley Water District, NV (USA))

1990-07-01T23:59:59.000Z

55

Proceedings: 4th EPRI International Decommissioning and Radioactive Waste Workshop, Madrid, Spain  

Science Conference Proceedings (OSTI)

EPRI held its 4th International Decommissioning Workshop in collaboration with ENRESA and Union Fenosa in Madrid, Spain. This workshop focused on a wide range of decommissioning topics, including general approaches, technical developments, and project experiences. The information presented will assist individual utilities in their planning and conduct of decommissioning projects with the potential to reduce decommissioning costs.

2006-06-12T23:59:59.000Z

56

Transient fault modeling and fault injection simulation  

E-Print Network (OSTI)

An accurate transient fault model is presented in this thesis. A 7-term exponential current upset model is derived from the results of a device-level, 3-dimensional, single-event-upset simulation. A curve-fitting algorithm is used to extract the numerical model from the empirical data. The model is implemented in a HSPICE simulation environment as a current-injection source for fault simulation. The current transient model is used to conduct electrical-level fault injection simulations on a static RAM cell and subcircuits from two commercial microprocessors. The results from the 7-term exponential model are compared with the results from the widely accepted double-exponential transient model. The experimental data indicate that, for a given charge level, the 7-term exponential fault model results in a higher chance of having a latch error. More importantly, different latch-error patterns are captured from the target circuits under the new fault model.

Yuan, Xuejun

1996-01-01T23:59:59.000Z

57

Active Faulting in the Coso Geothermal Field, Eastern California | Open  

Open Energy Info (EERE)

Faulting in the Coso Geothermal Field, Eastern California Faulting in the Coso Geothermal Field, Eastern California Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Conference Proceedings: Active Faulting in the Coso Geothermal Field, Eastern California Details Activities (1) Areas (1) Regions (0) Abstract: New mapping documents a series of late Quaternary NNE-striking normal faults in the central Coso Range that dip northwest, toward and into the main production area of the Coso geothermal field. The faults exhibit geomorphic features characteristic of Holocene activity, and locally are associated with fumaroles and hydothermal alteration. The active faults sole into or terminate against the brittle-ductile transition zone (BDT) at a depth of about 4 to 5 km. The BDT is arched upward over a volume of crust

58

A core-based assessment of the spatial relationship of small faults associated with a basement-controlled, large normal fault in the Hickory Sandstone  

E-Print Network (OSTI)

This research characterized a system of small faults (displacement < 0.3 m) in seven closely-spaced continuous 2.4 inch (6.1 cm) diameter cores. Cores were obtained from central Texas, on the western edge of the Llano Uplift. Cores penetrate a dip-slip dominant, normal fault (Nobles Fault) with 18.3 m (60 ft) of stratigraphic throw. The spatial, geometric and kinematic attributes of small faults within the Nobles Fault system were characterized to explore potential cause-and-effect relationships. To quantify spatial distributions, a "density" measure based on individual small fault magnitude was utilized. Approximately half of the small faults in the core possessed no discernible offset markers; thus displacement amount for these faults could not be measured directly. Using a nonparametric method in which an alternating conditional expectation determined optimal transformations for the data, a statistically significant empirical correlation was established for faults with measurable gouge thickness, displacement, protolith mean grain size and sorting. Gouge thickness of small faults was found to be dependant upon the displacement amount of the small fault and the textural characteristics of the host protolith. The role of protolith lithology, proximity to crystalline basement, and structural position relative to the Nobles Fault system were examined to explain observed ubiquitous spatial distribution of small faults. Small faults were found to occur in clusters and the number of faults per foot only weakly correlates to the cumulative displacement of the corresponding faults. The amount of mudstone present is the dominant factor controlling small fault formation. Intervals with only minor quantities of mudstone have the largest number of faults per foot as well as largest associated cumulative displacement per foot. Frequency of occurrence of small faults near the basement is greater when compared to similar lithologies higher in the core. Intensity of small faults do not universally increase with proximity to large faults. To observe an increase in small faults, it is necessary to use a mean global cumulative displacement approach. Zones of greater than average cumulative displacement of small faults in close proximity to large faults were observed in zones that are compatible with faultfault interaction.

Graff, Mitchell C

2006-08-01T23:59:59.000Z

59

Paleoseismology of latest Pleistocene and Holocene fault activity in central Oregon  

SciTech Connect

Latest Pleistocene and Holocene fault activity in Oregon concentrates along four zones that splay northward from seismically active faults along the Central Nevada and Eastern California seismic zones. The Central Oregon fault zone is one of these zones, which splays northward from dextral faults of the Walker Lane, stretching across the flanks of several ranges in south-central Oregon along a N20[degree]W trend, and ultimately merges with the Cascade volcanic arc near Newberry volcano. Aerial-photo interpretations and field investigations reveal fault scarps with, on average about 4 m, but in places as much as [approximately]10 m of vertical expression across latest Pleistocene pluvial lake deposits and geomorphic surfaces. Trenches across three different faults in the Central Oregon zone reveal evidence for multiple episodes of faulting in the form of fault-related colluvial deposits and deformed horizons which have been cut by younger fault movements. Trench exposures reveal faults with relatively steep dips and anastomosing traces, which are interpreted locally as evidence for a small oblique-slip component. Vertical offsets measured in the trenches are [approximately]2 m or more for each event. Radiocarbon analyses and preliminary tephra correlations indicate that the exposed deposits are [approximately]30,000 yr in age and younger, and record the decline of latest Pleistocene pluvial lakes. Commonly, reworked or deformed lacustrine deposits and interlayered and faulted colluvial deposits mark the second and third events back, which probably occurred in the Latest Pleistocene, at a time during low to moderate lake levels. If offsets of the past 18,000 yr are representative of the long-term average, then faults along this zone have slip rates of from 0.2 mm/yr to 0.6 mm/yr and recurrence intervals that range from [approximately]4,000 yr to 11,000 yr.

Pezzopane, S.K.; Weldon, R.J. II (Univ. of Oregon, Eugene, OR (United States). Dept. of Geological Sciences)

1993-04-01T23:59:59.000Z

60

New Madrid and Wabash Valley seismic study: simulating the impacts on natural gas transmission pipelines and downstream markets  

Science Conference Proceedings (OSTI)

This paper summarizes the methodology, simulation tools, and major initial findings made by Argonne National Laboratory (Argonne) on the potential impact of simultaneous, high-intensity New Madrid and Wabash Valley Seismic Events on the natural gas interstate ...

Edgar C. Portante; Stephen M. Folga; Gustav Wulfkuhle; Brian A. Craig; Leah E. Talaber

2009-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "madrid fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Fault Current Limiters  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Fault Fault Current Limiters Superconducting & Solid-state Power Equipment Office of Electricity Delivery and Energy Reliability www.oe.energy.gov Office of Electricity Delivery and Energy Reliability, OE-1 U.S. Department of Energy - 1000 Independence Avenue, SW - Washington, DC 20585 Plugging America Into the Future of Power What are FCLs? A fault is an unintentional short circuit, or partial short-circuit, in an electric circuit. A variety of factors such as lightning, downed power lines, or crossed power lines cause faults. During a fault, excessive current-called fault current- flows through the electrical system often resulting in a failure of one section of that system by causing a

62

An accelerated zone 2 trip algorithm for non-pilot distance relays  

Science Conference Proceedings (OSTI)

This paper presents an algorithm able to accelerate the zone 2 trip of non-pilot distance relays by detecting remote breaker operation following a zone 2 fault. It is based on monitoring changes in proposed composite signals. The performance of the proposed ... Keywords: accelerated trip (AT), real time digital simulator (RTDS), sequential accelerated trip (SAT), total fault clearing time (TFCT)

German Rosas Ortiz; Tarlochan S. Sidhu

2007-05-01T23:59:59.000Z

63

Risking fault seal in the Gulf Coast: A joint industry study  

SciTech Connect

Analysis of more than 200 faults in a joint-industry study of the Gulf Coast provides a database of actual fault seal behavior in producing fields. This empirical database demonstrates that fault seal behavior is predictable rather than random and that faults are more important than is commonly thought in controlling hydrocarbon accumulations. Quantitative fault seal analysis demonstrates that seal behavior is empirically related to the amount of sand and shale incorporated in the fault zone. Faults with sand-rich gouge leak. Faults with shale-rich gouge seal. An empirically defined threshold allows prediction of fault seal behavior with a high degree of confidence. Fewer than 10% of the faults in the Gulf Coast are exceptions to the rule. Exceptions are a result of other factors including low permeability and high displacement pressure sands, and thin-bedded sand/shale sequences. Examples from these Gulf Coast fields demonstrate the fundamental importance of faults in controlling hydrocarbon accumulations. Faults and fault seal behavior control the presence or absence of hydrocarbons, percent fill, hydrocarbon column heights, entrapment of oil versus gas, and high-side and low-side trap risk. Faults control the lateral distribution of hydrocarbon within fault compartments as well as the vertical distribution of hydrocarbon among stacked sands. Faults control fluid flow during both field development and hydrocarbon migration. Bypassed residual accumulations and unnecessary production wells result from neglecting routine fault seal analysis during field development. Dry holes and mistaken reserves assessments result from neglecting routine fault seal analysis during exploration.

Skerlec, G.M. (PetroQuest International Inc., Franklin, PA (United States))

1996-01-01T23:59:59.000Z

64

Solar system fault detection  

SciTech Connect

A fault detecting apparatus and method are provided for use with an active solar system. The apparatus provides an indication as to whether one or more predetermined faults have occurred in the solar system. The apparatus includes a plurality of sensors, each sensor being used in determining whether a predetermined condition is present. The outputs of the sensors are combined in a pre-established manner in accordance with the kind of predetermined faults to be detected. Indicators communicate with the outputs generated by combining the sensor outputs to give the user of the solar system and the apparatus an indication as to whether a predetermined fault has occurred. Upon detection and indication of any predetermined fault, the user can take appropriate corrective action so that the overall reliability and efficiency of the active solar system are increased.

Farrington, Robert B. (Wheatridge, CO); Pruett, Jr., James C. (Lakewood, CO)

1986-01-01T23:59:59.000Z

65

Solar system fault detection  

DOE Patents (OSTI)

A fault detecting apparatus and method are provided for use with an active solar system. The apparatus provides an indication as to whether one or more predetermined faults have occurred in the solar system. The apparatus includes a plurality of sensors, each sensor being used in determining whether a predetermined condition is present. The outputs of the sensors are combined in a pre-established manner in accordance with the kind of predetermined faults to be detected. Indicators communicate with the outputs generated by combining the sensor outputs to give the user of the solar system and the apparatus an indication as to whether a predetermined fault has occurred. Upon detection and indication of any predetermined fault, the user can take appropriate corrective action so that the overall reliability and efficiency of the active solar system are increased.

Farrington, R.B.; Pruett, J.C. Jr.

1984-05-14T23:59:59.000Z

66

Analysis of Fault Permeability Using Mapping and Flow Modeling, Hickory Sandstone Aquifer, Central Texas  

Science Conference Proceedings (OSTI)

Reservoir compartments, typical targets for infill well locations, are commonly created by faults that may reduce permeability. A narrow fault may consist of a complex assemblage of deformation elements that result in spatially variable and anisotropic permeabilities. We report on the permeability structure of a km-scale fault sampled through drilling a faulted siliciclastic aquifer in central Texas. Probe and whole-core permeabilities, serial CAT scans, and textural and structural data from the selected core samples are used to understand permeability structure of fault zones and develop predictive models of fault zone permeability. Using numerical flow simulation, it is possible to predict permeability anisotropy associated with faults and evaluate the effect of individual deformation elements in the overall permeability tensor. We found relationships between the permeability of the host rock and those of the highly deformed (HD) fault-elements according to the fault throw. The lateral continuity and predictable permeability of the HD fault elements enhance capability for estimating the effects of subseismic faulting on fluid flow in low-shale reservoirs.

Nieto Camargo, Jorge E., E-mail: jorge.nietocamargo@aramco.com; Jensen, Jerry L., E-mail: jjensen@ucalgary.ca [University of Calgary, Department of Chemical and Petroleum Engineering (Canada)

2012-09-15T23:59:59.000Z

67

Microstructures and Rheology of a Limestone-Shale Thrust Fault  

E-Print Network (OSTI)

The Copper Creek thrust fault in the southern Appalachians places Cambrian over Ordovician sedimentary strata. The fault accommodated displacement of 15-20 km at 100-180 C. Along the hanging wall-footwall contact, microstructures within a ~2 cm thick calcite and shale shear zone suggest that calcite, not shale, controlled the rheology of the shear zone rocks. While shale deformed brittley, plasticity-induced fracturing in calcite resulted in ultrafine-grained (shale into the shear zone, shows the evolution of rheology within the shear zone. Sedimentary laminations 1 cm below the shear zone are cut by minor faults, stylolites, and fault-parallel and perpendicular calcite veins. At vein intersections, calcite grain size is reduced (to ~0.3 ?m), and microstructures include inter-and-intragranular fractures, four-grain junctions, and interpenetrating boundaries. Porosity rises to 6 percent from shale clasts (5-350 ?m) lie within an ultrafine-grained calcite (shale matrix. Ultrafinegrained calcite (shale. Calcite vein microstructures suggest veins continued to form during deformation. Fractures at twin-twin and twin-grain boundary intersections suggest grain size reduction by plasticity-induced fracturing, resulting in <1 ?m grains. Interpenetrating boundaries, four-grain junctions, and no LPO indicate the ultrafine-grained calcite deformed by viscous grain boundary sliding. The evolution of the ultrafine-grain shear zone rocks by a combination of plastic and brittle processes and the deformation of the interconnected network of ultrafine-grained calcite by viscous GBS enabled a large displacement along a narrow fault zone.

Wells, Rachel Kristen

2010-12-01T23:59:59.000Z

68

Groundwater penetrating radar and high resolution seismic for locating shallow faults in unconsolidated sediments  

Science Conference Proceedings (OSTI)

Faults in shallow, unconsolidated sediments, particularly in coastal plain settings, are very difficult to discern during subsurface exploration yet have critical impact to groundwater flow, contaminant transport and geotechnical evaluations. This paper presents a case study using cross-over geophysical technologies in an area where shallow faulting is probable and known contamination exists. A comparison is made between Wenner and dipole-dipole resistivity data, ground penetrating radar, and high resolution seismic data. Data from these methods were verified with a cone penetrometer investigation for subsurface lithology and compared to existing monitoring well data. Interpretations from these techniques are compared with actual and theoretical shallow faulting found in the literature. The results of this study suggests that (1) the CPT study, combined with the monitoring well data may suggest that discontinuities in correlatable zones may indicate that faulting is present (2) the addition of the Wenner and dipole-dipole data may further suggest that offset zones exist in the shallow subsurface but not allow specific fault planes or fault stranding to be mapped (3) the high resolution seismic data will image faults to within a few feet of the surface but does not have the resolution to identify the faulting on the scale of our models, however it will suggest locations for upward continuation of faulted zones (4) offset 100 MHz and 200 MHz CMP GPR will image zones and features that may be fault planes and strands similar to our models (5) 300 MHz GPR will image higher resolution features that may suggest the presence of deeper faults and strands, and (6) the combination of all of the tools in this study, particularly the GPR and seismic may allow for the mapping of small scale, shallow faulting in unconsolidated sediments.

Wyatt, D.E. [Westinghouse Savannah River Co., Aiken, SC (United States)]|[South Carolina Univ., Columbia, SC (United States). Earth Sciences and Resources Inst.; Waddell, M.G. [South Carolina Univ., Columbia, SC (United States). Earth Sciences and Resources Inst.; Sexton, B.G. [Microseeps Ltd., Pittsburgh, PA (United States)

1993-12-31T23:59:59.000Z

69

Localization instability and the origin of regularly-spaced faults in planetary lithospheres  

E-Print Network (OSTI)

Brittle deformation is not distributed uniformly in planetary lithospheres but is instead localized on faults and ductile shear zones. In some regions such as the Central Indian Basin or martian ridged plains, localized ...

Montsi, Laurent Gilbert Joseph, 1973-

2002-01-01T23:59:59.000Z

70

Optimal fault location  

E-Print Network (OSTI)

Basic goal of power system is to continuously provide electrical energy to the users. Like with any other system, failures in power system can occur. In those situations it is critical that correct remedial actions are applied as soon as possible after the accurate fault condition and location are detected. This thesis has been focusing on automated fault location procedure. Different fault location algorithms, classified according to the spatial placement of physical measurements on single ended, multiple ended and sparse system-wide, are investigated. As outcome of this review, methods are listed as function of different parameters that influence their accuracy. This comparison is than used for generating procedure for optimal fault location algorithm selection. According to available data, and position of the fault with respect to the data, proposed procedure decides between different algorithms and selects an optimal one. A new approach is developed by utilizing different data structures such as binary tree and serialization in order to efficiently implement algorithm decision engine. After accuracy of algorithms is strongly influenced by available input data, different data sources are recommended in proposed architecture such as the digital fault recorders, circuit breaker monitoring, SCADA, power system model and etc. Algorithm for determining faulted section is proposed based on the data from circuit breaker monitoring devices. This algorithm works in real time by recognizing to which sequence of events newly obtained recording belongs. Software prototype of the proposed automated fault location analysis is developed using Java programming language. Fault location analysis is automatically triggered by appearance of new event files in a specific folder. The tests were carried out using the real life transmission system as an example.

Knezev, Maja

2007-12-01T23:59:59.000Z

71

Dorchester County- Renewable Zoning  

Energy.gov (U.S. Department of Energy (DOE))

Dorchester County zoning codes specifically permit solar arrays and small wind turbines in many zoning districts.

72

Integration of InSAR and GIS in the Study of Surface Faults Caused by Subsidence-Creep-Fault Processes in Celaya, Guanajuato, Mexico  

Science Conference Proceedings (OSTI)

In Celaya city, Subsidence-Creep-Fault Processes (SCFP) began to become visible at the beginning of the 1980s with the sprouting of the crackings that gave rise to the surface faults 'Oriente' and 'Poniente'. At the present time, the city is being affected by five surface faults that display a preferential NNW-SSE direction, parallel to the regional faulting system 'Taxco-San Miguel de Allende'. In order to study the SCFP in the city, the first step was to obtain a map of surface faults, by integrating in a GIS field survey and an urban city plan. The following step was to create a map of the current phreatic level decline in city with the information of deep wells and using the 'kriging' method in order to obtain a continuous surface. Finally the interferograms maps resulted of an InSAR analysis of 9 SAR images covering the time interval between July 12 of 2003 and May 27 of 2006 were integrated to a GIS. All the maps generated, show how the surface faults divide the city from North to South, in two zones that behave in a different way. The difference of the phreatic level decline between these two zones is 60 m; and the InSAR study revealed that the Western zone practically remains stable, while sinkings between the surface faults 'Oriente' and 'Universidad Pedagogica' are present, as well as in portions NE and SE of the city, all of these sinkings between 7 and 10 cm/year.

Avila-Olivera, Jorge A. [Instituto de Geofisica, Universidad Nacional Autonoma de Mexico, C.U., 04510 Mexico D.F. (Mexico); Instituto de Investigaciones Metalurgicas, Universidad Michoacana de San Nicolas de Hidalgo, C.U., 58030 Morelia, Michoacan (Mexico); Farina, Paolo [Dipartimento di Scienze della Terra, Universita degli Studi di Firenze, Via G. La Pira 4, 50121 Firenze (Italy); Garduno-Monroy, Victor H. [Instituto de Investigaciones Metalurgicas, Universidad Michoacana de San Nicolas de Hidalgo, C.U., 58030 Morelia, Michoacan (Mexico)

2008-05-07T23:59:59.000Z

73

Parallel fault backtracing for calculation of fault coverage  

Science Conference Proceedings (OSTI)

A new improved method for calculation of fault coverage with parallel fault backtracing in combinational circuits is proposed. The method is based on structurally synthesized BDDs (SSBDD) which represent gate-level circuits at higher, macro level where ...

Raimund Ubar; Sergei Devadze; Jaan Raik; Artur Jutman

2008-01-01T23:59:59.000Z

74

Fault Block Kinematics at a Releasing Stepover of the Eastern California  

Open Energy Info (EERE)

Fault Block Kinematics at a Releasing Stepover of the Eastern California Fault Block Kinematics at a Releasing Stepover of the Eastern California Shear Zone: Partitioning of Rotation Style in and Around the Coso Geothermal Area and Nascent Metamorphic Core Complex Jump to: navigation, search OpenEI Reference LibraryAdd to library Journal Article: Fault Block Kinematics at a Releasing Stepover of the Eastern California Shear Zone: Partitioning of Rotation Style in and Around the Coso Geothermal Area and Nascent Metamorphic Core Complex Abstract Pliocene lavas and sediments of Wild Horse Mesa in the Coso Range, CA exhibit clockwise vertical-axis rotation of fault-bounded blocks. This indicates localization of one strand of the Eastern California shear zone/Walker Lane Belt within a large-scale, transtensional, dextral, releasing stepover. We measured rotations paleomagnetically relative to two

75

Modeling of coulpled deformation and permeability evolution during fault reactivation induced by deep underground injection of CO2  

Science Conference Proceedings (OSTI)

The interaction between mechanical deformation and fluid flow in fault zones gives rise to a host of coupled hydromechanical processes fundamental to fault instability, induced seismicity, and associated fluid migration. In this paper, we discuss these coupled processes in general and describe three modeling approaches that have been considered to analyze fluid flow and stress coupling in fault-instability processes. First, fault hydromechanical models were tested to investigate fault behavior using different mechanical modeling approaches, including slip interface and finite-thickness elements with isotropic or anisotropic elasto-plastic constitutive models. The results of this investigation showed that fault hydromechanical behavior can be appropriately represented with the least complex alternative, using a finite-thickness element and isotropic plasticity. We utilized this pragmatic approach coupled with a strain-permeability model to study hydromechanical effects on fault instability during deep underground injection of CO{sub 2}. We demonstrated how such a modeling approach can be applied to determine the likelihood of fault reactivation and to estimate the associated loss of CO{sub 2} from the injection zone. It is shown that shear-enhanced permeability initiated where the fault intersects the injection zone plays an important role in propagating fault instability and permeability enhancement through the overlying caprock.

Cappa, F.; Rutqvist, J.

2010-06-01T23:59:59.000Z

76

European Wind Energy Conference & Exhibition EWEC 2003, Madrid, Spain. Forecasting of Regional Wind Generation by a Dynamic  

E-Print Network (OSTI)

European Wind Energy Conference & Exhibition EWEC 2003, Madrid, Spain. Forecasting of Regional Wind forecasting. I. INTRODUCTION HE actual large-scale integration of wind energy in several European countries enhance the position of wind energy compared to other dispatchable forms of generation. Predicting

Paris-Sud XI, Université de

77

DIFFERENTIAL FAULT SENSING CIRCUIT  

DOE Patents (OSTI)

A differential fault sensing circuit is designed for detecting arcing in high-voltage vacuum tubes arranged in parallel. A circuit is provided which senses differences in voltages appearing between corresponding elements likely to fault. Sensitivity of the circuit is adjusted to some level above which arcing will cause detectable differences in voltage. For particular corresponding elements, a group of pulse transformers are connected in parallel with diodes connected across the secondaries thereof so that only voltage excursions are transmitted to a thyratron which is biased to the sensitivity level mentioned.

Roberts, J.H.

1961-09-01T23:59:59.000Z

78

Computer hardware fault administration  

DOE Patents (OSTI)

Computer hardware fault administration carried out in a parallel computer, where the parallel computer includes a plurality of compute nodes. The compute nodes are coupled for data communications by at least two independent data communications networks, where each data communications network includes data communications links connected to the compute nodes. Typical embodiments carry out hardware fault administration by identifying a location of a defective link in the first data communications network of the parallel computer and routing communications data around the defective link through the second data communications network of the parallel computer.

Archer, Charles J. (Rochester, MN); Megerian, Mark G. (Rochester, MN); Ratterman, Joseph D. (Rochester, MN); Smith, Brian E. (Rochester, MN)

2010-09-14T23:59:59.000Z

79

Student Zone  

NLE Websites -- All DOE Office Websites (Extended Search)

Student Zone Student Zone Homework Helpers All About Atoms - Learn about the parts of the atom! Virginia State Standards of Learning Practice Tests - Practice taking the SOL tests! Subjects currently include algebra, math, science and technology. Table of Elements - Basic physical and historical information about the elements! [Printable Version] Questions and Answers - Have a question? Need an answer? Check here first! Glossary of Science Terms - Definitions of some of the terms used on this site. Jefferson Lab Virtual Tour - How do scientists explore inside atoms? Video Resources Frostbite Theater - Short science experiments using liquid nitrogen, static electricity and more! Physics Out Loud - Jefferson Lab scientists and other experts explain some of the common words and terms used in nuclear physics research.

80

Dynamic Fault Detection Chassis  

Science Conference Proceedings (OSTI)

Abstract The high frequency switching megawatt-class High Voltage Converter Modulator (HVCM) developed by Los Alamos National Laboratory for the Oak Ridge National Laboratory's Spallation Neutron Source (SNS) is now in operation. One of the major problems with the modulator systems is shoot-thru conditions that can occur in a IGBTs H-bridge topology resulting in large fault currents and device failure in a few microseconds. The Dynamic Fault Detection Chassis (DFDC) is a fault monitoring system; it monitors transformer flux saturation using a window comparator and dV/dt events on the cathode voltage caused by any abnormality such as capacitor breakdown, transformer primary turns shorts, or dielectric breakdown between the transformer primary and secondary. If faults are detected, the DFDC will inhibit the IGBT gate drives and shut the system down, significantly reducing the possibility of a shoot-thru condition or other equipment damaging events. In this paper, we will present system integration considerations, performance characteristics of the DFDC, and discuss its ability to significantly reduce costly down time for the entire facility.

Mize, Jeffery J [ORNL

2007-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "madrid fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Field Mapping At Central Nevada Seismic Zone Region (Shevenell, Et Al.,  

Open Energy Info (EERE)

Shevenell, Et Al., Shevenell, Et Al., 2008) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Field Mapping At Central Nevada Seismic Zone Region (Shevenell, Et Al., 2008) Exploration Activity Details Location Central Nevada Seismic Zone Geothermal Region Exploration Technique Field Mapping Activity Date Usefulness could be useful with more improvements DOE-funding Unknown Notes On a more local scale, Faulds et al. (2003, 2005a, 2005b, 2006) have conducted structural analysis and detailed geologic mapping at a number of sites throughout Nevada and have found that productive geothermal systems typically occur in one of several structural settings, including step-overs in normal fault zones, near the ends of major normal faults where the faults break into multiple splays, in belts of overlapping faults, at fault

82

Development of Hydrologic Characterization Technology of Fault Zones  

E-Print Network (OSTI)

and radiation in a multiphase, multicomponent, porous mediumin modeling multiphase flow in porous and fractured media,phase and multiphase non-Darcy flow in porous and fractured

Karasaki, Kenzi

2009-01-01T23:59:59.000Z

83

Development of Hydrologic Characterization Technology of Fault Zones  

E-Print Network (OSTI)

~FY2009 1. Field Investigation Conduct field investigationsinformation and conduct surface geologic investigation andat the detailed investigation stage. Conduct comprehensive

Karasaki, Kenzi

2009-01-01T23:59:59.000Z

84

Development of Hydrologic Characterization Technology of Fault Zones  

E-Print Network (OSTI)

modeling fluid and heat flow in fractured porous media, Soc.fluid flow, multicomponent transport, and heat transfer in porous and fractured media,fluid flow, solute transport, and heat transfer occur in porous and fractured media.

Karasaki, Kenzi

2009-01-01T23:59:59.000Z

85

Development of Hydrologic Characterization Technology of Fault Zones  

E-Print Network (OSTI)

113, 51-68. Swedish Nuclear Fuel and Waste Management Co. ,SEPM, 52 p. Swedish Nuclear Fuel and Waste Management Co. ,Disposal of Canadas Nuclear Fuel Waste. AECL -10711, COG-

Karasaki, Kenzi

2009-01-01T23:59:59.000Z

86

Development of Hydrologic Characterization Technology of Fault Zones  

E-Print Network (OSTI)

transport, and heat transfer processes in porous media.transport, and heat transfer, we assume that these processesprocesses, as described by Equation (4) or (8), as well as heat transfer,

Karasaki, Kenzi

2009-01-01T23:59:59.000Z

87

Development of Hydrologic Characterization Technology of Fault Zones  

E-Print Network (OSTI)

London) Special Publication 148, p. 117-134. Flint, A.L. ,Flint, L.E. , Bodvarsson, G.S. , Kwicklis, E.M. , andVol. 32, No. 9, 825-828, 2004b. Flint, A.L. , Flint, L.E. ,

Karasaki, Kenzi

2009-01-01T23:59:59.000Z

88

Development of Characterization Technology for Fault Zone Hydrology  

E-Print Network (OSTI)

conducted using electrical resistivity survey and seismicWF3 WF2 WF1 TR1 Electrical Resistivity Seismic Reflectionat depth. Four electrical resistivity surveys and three

Karasaki, Kenzi

2010-01-01T23:59:59.000Z

89

The paragenesis chemistry of alteration associated with the P2and fault in metamorphic rocks underlying the Athabasca Basin  

E-Print Network (OSTI)

's largest high-grade uranium deposit. This deposit is classified as unconformity-type because it is located: i) pitchblende at the uranium sMcArthur River deposit, ii) mineral perched within the overlying Zone 2 McArthur River Mine VQ Fault Fault Unconformity U-mineralization Pegmatite Quartzite Arkose

90

Faulting, fracturing, and sealing in foreland thrust belts: Examples from the subalpine chains  

SciTech Connect

The hydrocarbon potential of foreland thrust belts arises from source and reservoir rocks juxtaposed by the movement of thrust sheets, promoting maturation by loading and generating structural traps. Deformation in thrust belts can be localized on fault zones or distributed throughout thrust sheets; different deformation mechanisms operate to increase and decrease permeability. Migration and reservoir properties may be enhanced or reduced by faulting and fault-related deformation. These processes are examined in detail using examples from the northwest subalpine chains of France, a fold-and-thrust belt of well-differentiated Mesozoic shales and carbonates. Seeps of bitumen in foreland basin sediments indicate some migration of hydrocarbons along faults linking probable source and reservoir areas. Detailed examination of fault rocks and thrust sheets shows that fracture formation is an important strain mechanism which has the potential to form regions of enhanced permeability in structures such as hanging wall anticlines. However, the fractures observed are in general recemented, forming with crack-seal crystal growth. The faults themselves are complex zones up to tens of meters thick of subparallel anastomosing gouge, fractures, stylolites, and crystalline calcite, indicating synchronous cataclasis and pressure solution. The range of scales of fracturing suggests stick-slip (microseismic) fault activity. Permeability of the fault zones is enhanced during seismic fault slip and is otherwise steadily decreased by pressure solution and calcite deposition. The available migration pathways, and hence the location of potential reservoirs, is controlled by the timing, mechanisms, and extent of fault activity in this common and productive tectonic regime.

Bowler, S.; Butler, R.W.H.

1988-08-01T23:59:59.000Z

91

A High shear stress segment along the San Andreas Fault: Inferences based on near-field stress direction and stress magnitude observations in the Carrizo Plain Area  

SciTech Connect

Nearly 200 new in-situ determinations of stress directions and stress magnitudes near the Carrizo plain segment of the San Andreas fault indicate a marked change in stress state occurring within 20 km of this principal transform plate boundary. A natural consequence of this stress transition is that if the observed near-field ``fault-oblique`` stress directions are representative of the fault stress state, the Mohr-Coulomb shear stresses resolved on San Andreas sub-parallel planes are substantially greater than previously inferred based on fault-normal compression. Although the directional stress data and near-hydrostatic pore pressures, which exist within 15 km of the fault, support a high shear stress environment near the fault, appealing to elevated pore pressures in the fault zone (Byerlee-Rice Model) merely enhances the likelihood of shear failure. These near-field stress observations raise important questions regarding what previous stress observations have actually been measuring. The ``fault-normal`` stress direction measured out to 70 km from the fault can be interpreted as representing a comparable depth average shear strength of the principal plate boundary. Stress measurements closer to the fault reflect a shallower depth-average representation of the fault zone shear strength. If this is true, only stress observations at fault distances comparable to the seismogenic depth will be representative of the fault zone shear strength. This is consistent with results from dislocation monitoring where there is pronounced shear stress accumulation out to 20 km of the fault as a result of aseismic slip within the lower crust loading the upper locked section. Beyond about 20 km, the shear stress resolved on San Andreas fault-parallel planes becomes negligible. 65 refs., 15 figs.

Castillo, D. A., [Department of Geology and Geophysics, University of Adelaide (Australia); Younker, L.W. [Lawrence Livermore National Lab., CA (United States)

1997-01-30T23:59:59.000Z

92

Fault Current Management Guidebook - Updated  

Science Conference Proceedings (OSTI)

Under the new paradigm of power market operation, electric utilities are forcing more power through the existing transmission lines; and these increased loads will increase the fault current level throughout the power system. Also, new generation sources including distributed generation added at the transmission and distribution network will increase power flows and, consequently, fault current levels. Under increased power flow conditions on the existing assets, managing fault currents is crucial in ord...

2007-12-20T23:59:59.000Z

93

Fault Mapping | Open Energy Information  

Open Energy Info (EERE)

form form View source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit with form History Facebook icon Twitter icon » Fault Mapping Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: Fault Mapping Details Activities (2) Areas (2) Regions (0) NEPA(0) Exploration Technique Information Exploration Group: Field Techniques Exploration Sub Group: Data Collection and Mapping Parent Exploration Technique: Data Collection and Mapping Information Provided by Technique Lithology: Stratigraphic/Structural: Locates active faults in the area of interest Hydrological: Can reveal whether faults are circulating hydrothermal fluids Thermal: Dictionary.png

94

Imaging Faults with Reverse-Time Migration for Geothermal Exploration at Jemez Pueblo in New Mexico  

SciTech Connect

The fault zones at Jemez Pueblo may dominate the flow paths of hot water, or confine the boundaries of the geothermal reservoir. Therefore, it is crucial to image the geometry of these fault zones for geothermal exploration in the area. We use reverse-time migration with a separation imaging condition to image the faults at Jemez Pueblo. A finite-difference full-wave equation method with a perfectly-matching-layer absorbing boundary condition is used for backward propagation of seismic reflection data from receivers and forward propagation of wavefields from sources. In the imaging region, the wavefields are separated into the upgoing and downgoing waves, and leftgoing and rightgoing waves. The upgoing and downgoing waves are used to obtain the downward-looking image, and the leftgoing and rightgoing waves are used to form the left-looking image and right-looking image from sources. The left-looking and right-looking images are normally weaker than the downward-looking image because the reflections from the fault zones are much weaker than those from sedimentary layers, but these migration results contain the images of the faults. We apply our reverse-time migration with a wavefield separation imaging condition to seismic data acquired at Jemez Pueblo, and our preliminary results reveal many faults in the area.

Huang, Lianjie [Los Alamos National Laboratory; Albrecht, Michael [TBA Power; Kaufman, Greg [Jemez Purblo; Kelley, Shari [NM Bureau of Geology and Mineral Researces; Rehfeldt, Kenneth [Los Alamos National Laboratory; Zhang, Zhifu [EES-17 visitor

2011-01-01T23:59:59.000Z

95

Structural styles of the Wilcox and Frio growth-fault trends in Texas: Constraints on geopressured reservoirs  

DOE Green Energy (OSTI)

The wide variability in structural styles within the growth-faulted, geopressured trends of the Texas Gulf Coast is illustrated by detailed structural maps of selected areas of the Wilcox and Frio growth-fault trends and quantified by statistical analysis of fault compartment geometries. Structural variability is a key determinant of the size of geopressured aquifers in the deep subsurface. Two major structural styles exist in the Wilcox trend. (1) In southeast and Central Texas, the trend consists of continuous, closely spaced faults that have little associated rollover despite moderate expansion of section; the fault plane flattens little with depth. (2) By contrast, in South Texas a narrow band of growth faults having high expansion and moderate rollover lies above and downdip of a ridge of deformed, overpressured shale but updip of a deep basin formed by withdrawal of overpressured shale. Frio fault systems generally display greater rollover and wider spacing than do Wilcox fault systems; however, the Frio trend displays distinctive features in each study area. Most of the Frio growth faults, however, have a similar geometry, showing substantial rollover, expansion of section, and a moderate flattening of the fault zone with depth, possibly related to a deep decollement surface. The local variability in style is related to the magnitude of Frio sedimentation and progradation and to the presence of thick salt or shale. Finding and developing a large geopressured aquifer require recognition of a favorable combination of sand-body geometry, reservoir quality, and fault compartment size and shape.

Ewing, T.E.

1986-01-01T23:59:59.000Z

96

Multiple signal fault detection using fuzzy logic  

Science Conference Proceedings (OSTI)

In this paper, we describe a multiple Signal Fault Detection system that employs fuzzy logic at two levels of detection: signal segment fault and signal fault. The system involves signal segmentation, feature extraction and fuzzy logic based segment ...

Yi Lu Murphey; Jacob Crossman; ZhiHang Chen

2003-06-01T23:59:59.000Z

97

Definition: Enhanced Fault Protection | Open Energy Information  

Open Energy Info (EERE)

Enhanced Fault Protection Enhanced Fault Protection Enhanced fault protection requires higher precision and greater discrimination of fault location and type with coordinated measurement among multiple devices. For distribution applications, these systems will detect and isolate faults without full-power re-closing, reducing the frequency of through-fault currents. Using high resolution sensors and fault signatures, these systems can better detect high impedance faults. For transmission applications, these systems will employ high speed communications between multiple elements (e.g., stations) to protect entire regions, rather than just single elements. They will also use the latest digital techniques to advance beyond conventional impedance relaying of transmission lines.[1] Related Terms

98

Definition: Fault Mapping | Open Energy Information  

Open Energy Info (EERE)

Mapping Jump to: navigation, search Dictionary.png Fault Mapping Faults are structural features of crustal rocks that are caused by tectonic forces. These features can create...

99

Technology Zones (Virginia)  

Energy.gov (U.S. Department of Energy (DOE))

Virginias 26 designated Technology Zones offer tax relief in the form of abatements, credits, deductions, deferrals, exemptions, or rebates. Local governments may designate technology zones to...

100

Behavior of Late Quaternary and historical faults in the western Basin and Range province  

Science Conference Proceedings (OSTI)

Quaternary stratigraphic relations and exploratory trenching in zones of historical surface faulting in the western Basin and Range Province suggest that faults with historical surface ruptures have similar, and in some cases lower, long-term (late Quaternary) and short-term (Holocene) slip rates than other adjacent and regional non-historical Quaternary faults. In the 1954 Dixie Valley earthquake (M6.8) zone, the range-front and piedmont faults collectively record a late Quaternary (200 ka) slip rate on the order of 0.2 mm/yr and a Holocene (7--12 ka) slip rate of 0.5--0.8 mm/yr. The principal segment of the 1932 Cedar Mountain earthquake (M7.2) zone has an estimated latest Quaternary (25--35 ka) slip rate of 0.2--0.7 mm/yr and a Holocene (6--13 ka) slip rate of 0.3--0.7 mm/yr. The 1954 Rainbow Mountain earthquakes (M6.6 and M6.8) and 1954 Fairview Peak earthquake (M7.1) zones have late Quaternary slip rates that are lower (=] 1 mm/yr. Based on a comparison of Holocene and late Quaternary rates, many, but not all, historical and non-historical zones show evidence of temporal clustering.

Bell, J.W. (Univ. of Nevada, Reno, NV (United States). Nevada Bureau of Mines and Geology)

1993-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "madrid fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Arc fault detection system  

DOE Patents (OSTI)

An arc fault detection system for use on ungrounded or high-resistance-grounded power distribution systems is provided which can be retrofitted outside electrical switchboard circuits having limited space constraints. The system includes a differential current relay that senses a current differential between current flowing from secondary windings located in a current transformer coupled to a power supply side of a switchboard, and a total current induced in secondary windings coupled to a load side of the switchboard. When such a current differential is experienced, a current travels through a operating coil of the differential current relay, which in turn opens an upstream circuit breaker located between the switchboard and a power supply to remove the supply of power to the switchboard.

Jha, Kamal N. (Bethel Park, PA)

1999-01-01T23:59:59.000Z

102

Arc fault detection system  

DOE Patents (OSTI)

An arc fault detection system for use on ungrounded or high-resistance-grounded power distribution systems is provided which can be retrofitted outside electrical switchboard circuits having limited space constraints. The system includes a differential current relay that senses a current differential between current flowing from secondary windings located in a current transformer coupled to a power supply side of a switchboard, and a total current induced in secondary windings coupled to a load side of the switchboard. When such a current differential is experienced, a current travels through a operating coil of the differential current relay, which in turn opens an upstream circuit breaker located between the switchboard and a power supply to remove the supply of power to the switchboard. 1 fig.

Jha, K.N.

1999-05-18T23:59:59.000Z

103

Observer-based fault detection for nuclear reactors  

E-Print Network (OSTI)

This is a study of fault detection for nuclear reactor systems. Basic concepts are derived from fundamental theories on system observers. Different types of fault- actuator fault, sensor fault, and system dynamics fault ...

Li, Qing, 1972-

2001-01-01T23:59:59.000Z

104

EPRI Fault Current Management Guidebook, Fifth Edition  

Science Conference Proceedings (OSTI)

This document is an update of EPRI report 1020029, Fault Current Management Guidebook, Fourth Edition, on fault current effects and management in transmission and distribution systems. This guide is intended to be a snapshot of available references, information, and literature on the effects of high fault current on a number of power system components and various available and emerging fault-current-limiting technologies.

2011-12-19T23:59:59.000Z

105

Memory Fault Modeling Trends: A Case Study  

Science Conference Proceedings (OSTI)

In recent years, embedded memories are the fastest growing segment of system on chip. They therefore have a major impact on the overall Defect per Million (DPM). Further, the shrinking technologies and processes introduce new defects that cause previously ... Keywords: data backgrounds, dynamic faults, fault coverage, fault models, memory tests, static faults

Said Hamdioui; Rob Wadsworth; John Delos Reyes; Ad J. Van De Goor

2004-06-01T23:59:59.000Z

106

Gravity and fault structures, Long Valley caldera, California  

DOE Green Energy (OSTI)

The main and catastrophic phase of eruption in Long Valley occurred 0.73 m.y. ago with the eruption of over 600 km/sup 3/ of rhyolitic magma. Subsequent collapse of the roof rocks produced a caldera which is now elliptical in shape, 32 km east-west by 17 km north-south. The caldera, like other large Quarternary silicic ash-flow volcanoes that have been studied by various workers, has a nearly coincident Bouguer gravity low. Earlier interpretations of the gravity anomaly have attributed the entire anomaly to lower density rocks filling the collapsed structure. However, on the basis of many additional gravity stations and supporting subsurface data from several new holes, a much more complex and accurate picture has emerged of caldera structure. From a three-dimensional inversion of the residual Bouguer gravity data we can resolve discontinuities that seem to correlate with extensions of pre-caldera faults into the caldera and faults associated with the ring fracture. Some of these faults are believed related to the present-day hydrothermal upflow zone and the zone of youngest volcanic activity within the caldera.

Carle, S.F.; Goldstein, N.E.

1987-07-01T23:59:59.000Z

107

Fault Tree Analysis - A Bibliography  

Science Conference Proceedings (OSTI)

Fault tree analysis is a top-down approach to the identification of process hazards. It is touted as one of the best methods for systematically identifying and graphically displaying the many ways something can go wrong. This bibliography references ...

Program NASA Scientific and Technical Information

2000-07-01T23:59:59.000Z

108

SWIFT: Software Implemented Fault Tolerance  

Science Conference Proceedings (OSTI)

To improve performance and reduce power, processor designers employ advances that shrink feature sizes, lower voltage levels, reduce noise margins, and increase clock rates. However, these advances make processors more susceptible to transient faults ...

George A. Reis; Jonathan Chang; Neil Vachharajani; Ram Rangan; David I. August

2005-03-01T23:59:59.000Z

109

Passive fault current limiting device  

DOE Patents (OSTI)

A passive current limiting device and isolator is particularly adapted for use at high power levels for limiting excessive currents in a circuit in a fault condition such as an electrical short. The current limiting device comprises a magnetic core wound with two magnetically opposed, parallel connected coils of copper, a high temperature superconductor or other electrically conducting material, and a fault element connected in series with one of the coils. Under normal operating conditions, the magnetic flux density produced by the two coils cancel each other. Under a fault condition, the fault element is triggered to cause an imbalance in the magnetic flux density between the two coils which results in an increase in the impedance in the coils. While the fault element may be a separate current limiter, switch, fuse, bimetal strip or the like, it preferably is a superconductor current limiter conducting one-half of the current load compared to the same limiter wired to carry the total current of the circuit. The major voltage during a fault condition is in the coils wound on the common core in a preferred embodiment. 6 figs.

Evans, D.J.; Cha, Y.S.

1999-04-06T23:59:59.000Z

110

Automatic fault extraction and simulation of layout realistic faults for integrated analogue circuits  

Science Conference Proceedings (OSTI)

A comprehensive tool has been implemented for the comparison of different test preparation techniques and target faults. It comprises of the realistic fault characterisation program LIFT that can extract sets of various faults from a given analogue or ... Keywords: AnaFAUL, LIFT, VCO, analogue integrated circuits, automatic analogue fault simulation program, catastrophic faults, circuit analysis computing, circuit layout, fault diagnosis, integrated analogue circuits, integrated circuit layout, integrated circuit testing, mixed analogue-digital integrated circuits, mixed-signal circuit, parametric faults, realistic fault characterisation program, simulation, test preparation, voltage-controlled oscillators

C. Sebeke; J. P. Teixeira; M. J. Ohletz

1995-03-01T23:59:59.000Z

111

Fault detection of fault ride through for doubly-fed induction generator based wind energy systems.  

E-Print Network (OSTI)

??Fault detection and mitigation is of high importance for existing DFIG based wind energy conversion systems. Keeping the doubly-fed induction generator (DFIG) online during faults (more)

Ramroop, Shoba AD

2008-01-01T23:59:59.000Z

112

Enterprise Zone Program (Illinois)  

Energy.gov (U.S. Department of Energy (DOE))

The Enterprise Zone Program provides eligible businesses that relocate or expand to a designated zone with tax incentives such as: 1) an investment tax credit; 2) a job tax credit for each job...

113

MODIFIED ZONE METHOD CALCULATOR  

NLE Websites -- All DOE Office Websites (Extended Search)

Zone Method is recommended for R-value calculations in steel stud walls by the 1997 ASHRAE Handbook of Fundamentals ASHRAE 1997. The Modified Zone Method is similar to the...

114

Reinvestment Zones (Texas)  

Energy.gov (U.S. Department of Energy (DOE))

Reinvestment Zones a local economic development tool used by municipalities and counties throughout the state of Texas. These zones can be created for the purpose of granting local businesses ad...

115

Thoughts Regarding the Dimensions of Faults at Rainier and Aqueduct Mesas, Nye County, Nevada, Based on Surface and Underground Mapping  

Science Conference Proceedings (OSTI)

The geologic setting and history, along with observations through 50 years of detailed geologic field work, show that large-displacement (i.e., greater than 30 meters of displacement) syn- to post-volcanic faults are rare in the Rainier Mesa area. Faults observed in tunnels and drill holes are mostly tight, with small displacements (most less than 1.5 meters) and small associated damage zones. Faults are much more abundant in the zeolitized tuffs than in the overlying vitric tuffs, and there is little evidence that faults extend downward from the tuff section through the argillic paleocolluvium into pre-Tertiary rocks. The differences in geomechanical characteristics of the various tuff lithologies at Rainier Mesa suggest that most faults on Rainer Mesa are limited to the zeolitic units sandwiched between the overlying vitric bedded tuffs and the underlying pre-Tertiary units (lower carbonate aquifer3, lower clastic confining unit1, and Mesozoic granite confining unit).

Drellack, S.L.; Prothro, L.B.; Townsend, M.J.; Townsend, D.R.

2011-02-01T23:59:59.000Z

116

Field Mapping At Walker-Lane Transitional Zone Region (Shevenell, Et Al.,  

Open Energy Info (EERE)

Walker-Lane Transitional Zone Region (Shevenell, Et Al., Walker-Lane Transitional Zone Region (Shevenell, Et Al., 2008) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Field Mapping At Walker-Lane Transitional Zone Region (Shevenell, Et Al., 2008) Exploration Activity Details Location Walker-Lane Transition Zone Geothermal Region Exploration Technique Field Mapping Activity Date Usefulness could be useful with more improvements DOE-funding Unknown Notes On a more local scale, Faulds et al. (2003, 2005a, 2005b, 2006) have conducted structural analysis and detailed geologic mapping at a number of sites throughout Nevada and have found that productive geothermal systems typically occur in one of several structural settings, including step-overs in normal fault zones, near the ends of major normal faults where the

117

ASHRAE Climate Zones | Open Energy Information  

Open Energy Info (EERE)

ASHRAE Climate Zones Jump to: navigation, search Subtype A Subtype B Subtype C Climate Zone Number 1 Zone 1A Zone 1B NA Climate Zone Number 2 Zone 2A Zone 2B NA Climate Zone...

118

Fault block kinematics at a releasing stepover of the Eastern California  

Open Energy Info (EERE)

block kinematics at a releasing stepover of the Eastern California block kinematics at a releasing stepover of the Eastern California shear zone: Partitioning of rotation style in and around the Coso geothermal area and nascent metamorphic core complex Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: Fault block kinematics at a releasing stepover of the Eastern California shear zone: Partitioning of rotation style in and around the Coso geothermal area and nascent metamorphic core complex Details Activities (1) Areas (1) Regions (0) Abstract: Pliocene lavas and sediments of Wild Horse Mesa in the Coso Range, CA exhibit clockwise vertical-axis rotation of fault-bounded blocks. This indicates localization of one strand of the Eastern California shear zone/Walker Lane Belt within a large-scale, transtensional, dextral,

119

Definition: Fault Current Limiting | Open Energy Information  

Open Energy Info (EERE)

Limiting Limiting Jump to: navigation, search Dictionary.png Fault Current Limiting Fault current limiting can be achieved through sensors, communications, information processing, and actuators that allow the utility to use a higher degree of network coordination to reconfigure the system to prevent fault currents from exceeding damaging levels. Fault current limiting can also be achieved through the implementation of special stand alone devices known as Fault Current Limiters (FCLs) which act to automatically limit high through currents that occur during faults.[1] Related Terms fault, fault current limiter References ↑ SmartGrid.gov 'Description of Functions' Temp LikeLike UnlikeLike You like this.Sign Up to see what your friends like. late:ISGANAttributionsmart grid,smart grid,smart grid,smart grid,

120

Definition: Fault Current Limiter | Open Energy Information  

Open Energy Info (EERE)

Limiter Limiter Jump to: navigation, search Dictionary.png Fault Current Limiter A fault current limiter prevents current in an electrical circuit from exceeding a predetermined level by increasing the electrical impedance of that circuit before the current through the circuit exceeds that level. Fault current limiters are designed so as to minimize the impedance of the circuit under normal conditions to reduce losses, but increase the impedance of the circuit under fault conditions to limit fault current.[1] View on Wikipedia Wikipedia Definition A Fault Current Limiter (FCL) is a device which limits the prospective fault current when a fault occurs (e.g. in a power transmission network). The term includes superconducting devices and non-superconducting devices, however some of the more simple non-superconducting devices (such

Note: This page contains sample records for the topic "madrid fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Fault diagnosis and fault tolerant control using set-membership approaches: Application to real case studies  

Science Conference Proceedings (OSTI)

This paper reviews the use of set-membership methods in fault diagnosis (FD) and fault tolerant control (FTC). Setmembership methods use a deterministic unknown-but-bounded description of noise and parametric uncertainty (interval ... Keywords: Fault Detection, Fault-Tolerant Control, Interval Models, Robustness, Set-Membership

Vicen Puig

2010-12-01T23:59:59.000Z

122

Distribution Fault Location and Waveform Characterization  

Science Conference Proceedings (OSTI)

Automated fault location algorithms for distribution systems require monitoring equipment to record voltage and current waveforms during an event. In addition, most of these algorithms require circuit-impedance parameters to evaluate the fault location. Locating incipient faults and fault waveform characterization is the main aim of this project. This project builds on work done in 2008 towards sub-cycle blip identification using an algorithm based on arc voltage.

2009-12-11T23:59:59.000Z

123

Benchmarking of Fault-Location Technologies  

Science Conference Proceedings (OSTI)

This report resumes the studies on fault-location technologies that were conducted in 2009. These studies were undertaken in a joint project done with the collaboration of Hydro-Qubec, Long Island Power Authority, and the Electric Power Research Institute (EPRI). Two fault-location technologies were tested, the Reactance to Fault (RTF) implemented in the PQView application and the Voltage Drop Fault Location (VDFL) implemented in the MILE application. The RTF is based on substation voltage and current me...

2011-03-31T23:59:59.000Z

124

High temperature superconducting fault current limiter  

DOE Patents (OSTI)

A fault current limiter for an electrical circuit is disclosed. The fault current limiter includes a high temperature superconductor in the electrical circuit. The high temperature superconductor is cooled below its critical temperature to maintain the superconducting electrical properties during operation as the fault current limiter. 15 figs.

Hull, J.R.

1997-02-04T23:59:59.000Z

125

Autonomic fault mitigation in embedded systems  

Science Conference Proceedings (OSTI)

Autonomy, particularly from a maintenance and fault-management perspective, is an increasingly desirable feature in embedded (and non-embedded) computer systems. The driving factors are several-including increasing pervasiveness of computer systems, ... Keywords: Autonomic computing, Embedded systems, Fault mitigation, Fault tolerance, Hierarchical concurrent finite-state machines, Model-based design

Sandeep Neema; Ted Bapty; Shweta Shetty; Steven Nordstrom

2004-10-01T23:59:59.000Z

126

Fault detection and diagnosis of technical systems  

Science Conference Proceedings (OSTI)

Sensors, actuators and/or physical components in technical systems are often affected by unpermitted or un-expected deviations from normal operation behaviour. The fault diagnosis task consists of determination of the fault type with as many details ... Keywords: fault detection and diagnosis, residuals, symptoms, technical systems

Ioana Fagarasan; S. ST. Iliescu

2008-06-01T23:59:59.000Z

127

CRT RSA algorithm protected against fault attacks  

Science Conference Proceedings (OSTI)

Embedded devices performing RSA signatures are subject to Fault Attacks, particularly when the Chinese Remainder Theorem is used. In most cases, the modular exponentiation and the Garner recombination algorithms are targeted. To thwart Fault Attacks, ... Keywords: RSA, chinese remainder theorem, fault attacks, modular exponentiation, simple power analysis, smart card

Arnaud Boscher; Robert Naciri; Emmanuel Prouff

2007-05-01T23:59:59.000Z

128

Designing Fault-Tolerant Mobile Systems  

Science Conference Proceedings (OSTI)

The purpose of this paper is to investigate how several innovative techniques, not all initially intended for fault-tolerance, can be applied in providing fault tolerance of complex mobile agent systems. Due to their roaming nature, mobile agents usually ... Keywords: exception handling, fault tolerance, mobile agents, software engineering, system structuring

Giovanna Di Marzo Serugendo; Alexander B. Romanovsky

2002-11-01T23:59:59.000Z

129

High-resolution stratigraphic and structural characterization of the fault-partitioned Hickory Sandstone aquifer system, Mason County, central Texas  

E-Print Network (OSTI)

The Hickory Sandstone is an important aquifer in central Texas and is partitioned by faults that impede cross-fault fluid flow. This study provides a detailed stratigraphic and structural model in the vicinity of a normal, oblique-slip fault with 60' (18.3 m) of stratigraphic throw. The model is developed using 3500' (1050 m) of continuous core and geophysical logs from eleven closely spaced boreholes. The local stratigraphy is studied in detail and environments of deposition inferred. A model of fault evolution is inferred using the observed fault structure and throw distributions. Locally, the Hickory Sandstone consists of 450' (137 m) of Cambrian-aged, quartzose and arkosic sandstone with localized mudstone and siltstone interbeds and overlies Precambrian Town Mountain Granite. Within the study area, the Hickory Sandstone is subdivided into four facies: the cross-bedded facies, the mudstone facies, the interbedded sandstone facies and the hematite facies. These facies form a stacked sequence representing an initial braided-stream fluvial environment that grades into a high energy, open marine environment that closely matches the tide-dominated, high microtidal estuarine model of Reinson (1992). Lateral correlation of strata packages in the cross-bedded facies was very difficult and complicated development of the fault model. The study fault is a linked fault system consisting of several major segments. Two segments overlap and locally hard link along both strike and dip. The major fault segments also consist of several linked subsegments. Net stratigraphic throw decreases slightly upward from a maximum of 60' (18.3 m) near the granite basement. Where the major segments overlap, the throw exhibits systematic variations consistent with displacement transfer between the neighboring segments. The linked fault system is inferred to have formed by interaction and linkage of two, early, en echelon basement faults. Ultimately these faults propagated upward and laterally into the overlying Hickory Sandstone, interacted and partially hard-linked, producing a large linkage structure that affected subsequent, neighboring hanging wall deformation. Subsidiary small faults are common but do not exhibit simple spatial relations with the large fault segments. There is only a weak correlation between a fault's shear zone thickness and stratigraphic throw for faults with 1' to 60' (0.3 to 18.3 m) of throw.

Wilson, Jason Steven

2001-01-01T23:59:59.000Z

130

Geothermal: Educational Zone  

NLE Websites -- All DOE Office Websites (Extended Search)

GEOTHERMAL TECHNOLOGIES LEGACY COLLECTION - Educational Zone Geothermal Technologies Legacy Collection HelpFAQ | Site Map | Contact Us | Admin Log On HomeBasic Search About...

131

Renaissance Zones (North Dakota)  

Energy.gov (U.S. Department of Energy (DOE))

Renaissance Zones allow qualifying businesses and individuals to claim one or more tax incentives for purchasing, leasing, or making improvements to real property located in a North Dakota...

132

Isotopic evidence for the infiltration of mantle and metamorphic CO2-H2O fluids from below in faulted rocks from the San Andreas Fault System  

SciTech Connect

To characterize the origin of the fluids involved in the San Andreas Fault (SAF) system, we carried out an isotope study of exhumed faulted rocks from deformation zones, vein fillings and their hosts and the fluid inclusions associated with these materials. Samples were collected from segments along the SAF system selected to provide a depth profile from upper to lower crust. In all, 75 samples from various structures and lithologies from 13 localities were analyzed for noble gas, carbon, and oxygen isotope compositions. Fluid inclusions exhibit helium isotope ratios ({sup 3}He/{sup 4}He) of 0.1-2.5 times the ratio in air, indicating that past fluids percolating through the SAF system contained mantle helium contributions of at least 35%, similar to what has been measured in present-day ground waters associated with the fault (Kennedy et al., 1997). Calcite is the predominant vein mineral and is a common accessory mineral in deformation zones. A systematic variation of C- and O-isotope compositions of carbonates from veins, deformation zones and their hosts suggests percolation by external fluids of similar compositions and origin with the amount of fluid infiltration increasing from host rocks to vein to deformation zones. The isotopic trend observed for carbonates in veins and deformation zones follows that shown by carbonates in host limestones, marbles, and other host rocks, increasing with increasing contribution of deep metamorphic crustal volatiles. At each crustal level, the composition of the infiltrating fluids is thus buffered by deeper metamorphic sources. A negative correlation between calcite {delta}{sup 13}C and fluid inclusion {sup 3}He/{sup 4}He is consistent with a mantle origin for a fraction of the infiltrating CO{sub 2}. Noble gas and stable isotope systematics show consistent evidence for the involvement of mantle-derived fluids combined with infiltration of deep metamorphic H{sub 2}O and CO{sub 2} in faulting, supporting the involvement of deep fluids percolating through and perhaps weakening the fault zone. There is no clear evidence for a significant contribution from meteoric water, except for overprinting related to late weathering.

Pili, E.; Kennedy, B.M.; Conrad, M.E.; Gratier, J.-P.

2010-12-15T23:59:59.000Z

133

Barriers to faulting in the Basin-Range province: evidence from the Sou Hills transverse block  

Science Conference Proceedings (OSTI)

Transverse structural blocks may inhibit the propagation of fault ruptures in the Basin-Range province. The Sou Hills, between Dixie and Pleasant Valleys, is a block of uplifted Tertiary bedrock transverse to the NNE-SSW trend of the central Nevada seismic belt. Three lines of evidence indicate that offset due to normal faulting is much less in the Sou Hills compared to adjacent segments of the seismic belt. First, estimates of total late Cenozoic offsets of pre-extension basalts show that the total offset is less in the Sou Hills. Second, analyses of landforms that reflect rates of relative uplift show that Quaternary tectonic activity on range-bounding faults declines where faults join the Sou Hills. Third, measurements of late Quaternary fault scarps show that individual rupture segments in the Sou Hills are shorter in length and have smaller displacements compared to the nearly continuous ruptures of several meters offset found along the Tobin and Stillwater Ranges to the north and south. The Sou Hills rupture pattern is distinctive: ruptures are dispersed over a wide zone rather than being concentrated along well-defined range fronts. Normal faulting patterns produced by the 1915 Pleasant Valley, Nevada and the 1983 Borah Peak, Idaho earthquakes indicate that a discontinuous, spatially dispersed faulting style typifies ruptures which die out in transverse bedrock features. These historic analogues support a model for prehistoric faulting in which ruptures have repeatedly died out in the Sou Hills. Transverse blocks such as the Sou Hills appear to present barriers to propagating ruptures.

Fonseca, J.E.

1985-01-01T23:59:59.000Z

134

Fault-ignorant Quantum Search  

E-Print Network (OSTI)

We investigate the problem of quantum searching on a noisy quantum computer. Taking a 'fault-ignorant' approach, we analyze quantum algorithms that solve the task for various different noise strengths, which are possibly unknown beforehand. We prove lower bounds on the runtime of such algorithms and thereby find that the quadratic speedup is necessarily lost (in our noise models). However, for low but constant noise levels the algorithms we provide (based on Grover's algorithm) still outperform the best noiseless classical search algorithm.

Peter Vrana; David Reeb; Daniel Reitzner; Michael M. Wolf

2013-07-02T23:59:59.000Z

135

CONTROL AND FAULT DETECTOR CIRCUIT  

DOE Patents (OSTI)

A power control and fault detectcr circuit for a radiofrequency system is described. The operation of the circuit controls the power output of a radio- frequency power supply to automatically start the flow of energizing power to the radio-frequency power supply and to gradually increase the power to a predetermined level which is below the point where destruction occurs upon the happening of a fault. If the radio-frequency power supply output fails to increase during such period, the control does not further increase the power. On the other hand, if the output of the radio-frequency power supply properly increases, then the control continues to increase the power to a maximum value. After the maximumn value of radio-frequency output has been achieved. the control is responsive to a ''fault,'' such as a short circuit in the radio-frequency system being driven, so that the flow of power is interrupted for an interval before the cycle is repeated.

Winningstad, C.N.

1958-04-01T23:59:59.000Z

136

Historic Surface Faulting and Paleoseismicity in the Area of the 1954  

Open Energy Info (EERE)

Historic Surface Faulting and Paleoseismicity in the Area of the 1954 Historic Surface Faulting and Paleoseismicity in the Area of the 1954 Rainbow Mountain-Stillwater Earthquake Sequence, Central Nevada Jump to: navigation, search OpenEI Reference LibraryAdd to library Journal Article: Historic Surface Faulting and Paleoseismicity in the Area of the 1954 Rainbow Mountain-Stillwater Earthquake Sequence, Central Nevada Abstract The Rainbow Mountain area was the site of three surface-rupturing earthquakes on 6 July and 23 August 1954. More than 50 field measurements of surface offsets constrain the distribution of slip along the discontinuous and distributed rupture zone that formed during the earthquake sequence. Vertical offsets reach a maximum of ~0.8 m with the average vertical offset being ~0.2 m. In contrast to original reports, we

137

Intersecting Fault Trends and Crustal-Scale Fluid Pathways Below the Dixie  

Open Energy Info (EERE)

Intersecting Fault Trends and Crustal-Scale Fluid Pathways Below the Dixie Intersecting Fault Trends and Crustal-Scale Fluid Pathways Below the Dixie Valley Geothermal Area, Nevada, Inferred from 3d Magnetotelluric Surveying Jump to: navigation, search OpenEI Reference LibraryAdd to library Conference Paper: Intersecting Fault Trends and Crustal-Scale Fluid Pathways Below the Dixie Valley Geothermal Area, Nevada, Inferred from 3d Magnetotelluric Surveying Abstract Geothermal systems may occur in zones of structural dilatency which create the crustal plumbing that al-lows concentration of high-temperature fluids from surrounding volumes. While structural orientations of the U.S. Great Basin are dominated visually by the NNE-oriented horst-graben morphology, other alignments are apparent, perhaps principally a NNW-trending grain

138

Hardware Fault Insertion Techniques and Tools  

E-Print Network (OSTI)

The concept of dependability validation becomes more and more important regarding big public telecom systems. This is why fault insertion has been widely accepted as a means of testing the fault handling mechanisms of the systems. This master thesis classifies and compares fault insertion techniques used within the industry. It also looks into internal fault insertion techniques used by the people at Ericsson Telecom working with the AXD301 ATM switch. Hardware Fault Insertion Techniques and Tools 2 Acknowledgements The following people at Ericsson has contributed to this thesis in one way or another: Roger Nordmark Mattias Rimbark Bengt Kvist Anders strm Kenny Ohlsson Johan Jeppson Johan Eklv Also a thank you to my supervisor at KTH: Axel Jantsch A special thanks also to my good friend and colleague: Robert Thorhuus Hardware Fault Insertion Techniques and Tools 3 Abbreviations ASIC - Application Specific Integrated Circuit ATM - Asynchronous Transfer Mode BSDL - Boundary Scan De...

Emil Savqvist; Roger Nordmark; Mattias Rimbark; Bengt Kvist; Anders strm; Kenny Ohlsson; Johan Eklv; Axel Jantsch; Robert Thorhuus; Hw Hard Ware

2000-01-01T23:59:59.000Z

139

Fault Current Management Guidebook--Updated  

Science Conference Proceedings (OSTI)

Due to increased load demands and reduced incentives to build new transmission, energy companies are increasing power flows on existing transmission assets, which will increase fault current levels throughout the power system. Also, new generation sources to be added at the transmission and distribution network will increase power flows and, consequently, fault current levels. Under increased power flow conditions on existing assets, managing fault currents is crucial for avoiding damage to equipment as ...

2006-11-28T23:59:59.000Z

140

Fault Tree Based Diagnostics Using Fuzzy Logic  

Science Conference Proceedings (OSTI)

Fuzzy set theory is investigated as a tool for the diagnostics of systems described by means of a fault tree. The objective is to diagnose component failures from the observation of fuzzy symptoms using the information contained in a fault tree. A two-step ... Keywords: causal reasoning, component failures, failure analysis, failure modes, fault tree based diagnostics, fuzzy logic, fuzzy symptoms, minimal cut-sets, triggered gates, two-step procedure

P. Gmytrasiewicz; J. A. Hassberger; J. C. Lee

1990-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "madrid fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Development Opportunity Zone Credit  

Energy.gov (U.S. Department of Energy (DOE))

The Development Opportunity Zone Credits incent new and expanding businesses in the Cities of Beloit, Janesville and Kenosha by providing non-refundable tax credits to assist with the creation and...

142

Keystone Opportunity Zones (Pennsylvania)  

Energy.gov (U.S. Department of Energy (DOE))

Keystone Opportunity Zones allows businesses located within designated areas to qualify for a tax exemption, deduction, credit, or abatement of state and local taxes such as sales and use tax,...

143

Deep Vadose Zone  

Energy.gov (U.S. Department of Energy (DOE))

The Mission of the Deep Vadose Zone Applied Field Research Initiative is to protect water resources across the DOE complex over the long-term by developing effective solutions to solve DOEs most...

144

Fault diagnosis in reversible circuits under missing-gate fault model  

Science Conference Proceedings (OSTI)

This article presents a novel technique for fault detection as well as fault location in a reversible combinational circuit under the missing gate fault model. It is shown that in an (nxn) reversible circuit implemented with k-CNOT gates, addition of ...

Hafizur Rahaman; Dipak K. Kole; Debesh K. Das; Bhargab B. Bhattacharya

2011-07-01T23:59:59.000Z

145

Queen Anne's County- Solar Zoning  

Energy.gov (U.S. Department of Energy (DOE))

Queen Anne's County zoning code allows for ground mounted solar arrays in areas zoned as "open space," "agricultural," and "countryside" districts.

146

Crossing Active Faults on the Sakhalin II Onshore Pipeline Route: Pipeline Design and Risk Analysis  

SciTech Connect

Twin oil (20 and 24 inch) and gas (20 and 48 inch) pipeline systems stretching 800 km are being constructed to connect offshore hydrocarbon deposits from the Sakhalin II concession in the North to an LNG plant and oil export terminal in the South of Sakhalin island. The onshore pipeline route follows a regional fault zone and crosses individual active faults at 19 locations. Sakhalin Energy, Design and Construction companies took significant care to ensure the integrity of the pipelines, should large seismic induced ground movements occur during the Operational life of the facilities. Complex investigations including the identification of the active faults, their precise location, their particular displacement values and assessment of the fault kinematics were carried out to provide input data for unique design solutions. Lateral and reverse offset displacements of 5.5 and 4.5 m respectively were determined as the single-event values for the design level earthquake (DLE) - the 1000-year return period event. Within the constraints of a pipeline route largely fixed, the underground pipeline fault crossing design was developed to define the optimum routing which would minimize stresses and strain using linepipe materials which had been ordered prior to the completion of detailed design, and to specify requirements for pipe trenching shape, materials, drainage system, etc. Detailed Design was performed with due regard to actual topography and to avoid the possibility of the trenches freezing in winter, the implementation of specific drainage solutions and thermal protection measures.

Mattiozzi, Pierpaolo [Snamprogetti-Saipem, Via Toniolo, 1, 61032 Fano (Italy); Strom, Alexander [Institute of Geospheres Dynamics, Leninskiy Avenue, 38, Building 1, 119334, Moscow (Russian Federation)

2008-07-08T23:59:59.000Z

147

Crossing Active Faults on the Sakhalin II Onshore Pipeline Route: Analysis Methodology and Basic Design  

Science Conference Proceedings (OSTI)

Twin oil (20 and 24 inch) and gas (20 and 48 inch) pipeline systems stretching 800 km are being constructed to connect offshore hydrocarbon deposits from the Sakhalin II concession in the North to an LNG plant and oil export terminal in the South of Sakhalin island. The onshore pipeline route follows a regional fault zone and crosses individual active faults at 19 locations. Sakhalin Energy, Design and Construction companies took significant care to ensure the integrity of the pipelines, should large seismic induced ground movements occur during the Operational life of the facilities. Complex investigations including the identification of the active faults, their precise location, their particular displacement values and assessment of the fault kinematics were carried out to provide input data for unique design solutions. Lateral and reverse offset displacements of 5.5 and 4.5 m respectively were determined as the single-event values for the design level earthquake (DLE)--the 1000-year return period event. Within the constraints of a pipeline route largely fixed, the underground pipeline fault crossing design was developed to define the optimum routing which would minimize stresses and strain using linepipe materials which had been ordered prior to the completion of detailed design, and to specify requirements for pipe trenching shape, materials, drainage system, etc. This Paper describes the steps followed to formulate the concept of the special trenches and the analytical characteristics of the Model.

Vitali, Luigino [Snamprogetti-Saipem, Via Toniolo, 1, 61032 Fano, Luigino (Italy); Mattiozzi, Pierpaolo [Snamprogetti-Saipem, Via Toniolo, 1, 61032 Fano (Italy)

2008-07-08T23:59:59.000Z

148

Distribution Fault Location Support Tools, Algorithms, and Implementation Approaches  

Science Conference Proceedings (OSTI)

Distribution grid modernization applications such as fault location and automatic sectionalizing require an accurate assessment of fault current. More-accurate prediction of fault locations will shorten the fault investigation (patrol) time, which in turn can reduce the total restoration time and duration of the outage experienced by the customer. This EPRI technical update report presents information on fault location applications, enumerates different methods used to detect the location of faults, ...

2013-08-14T23:59:59.000Z

149

ARMor: fully verified software fault isolation  

Science Conference Proceedings (OSTI)

We have designed and implemented ARMor, a system that uses software fault isolation (SFI) to sandbox application code running on small embedded processors. Sandboxing can be used to protect components such as the RTOS and critical control loops from ... Keywords: arm executables, automated theorem proving, program logic, software fault isolation

Lu Zhao; Guodong Li; Bjorn De Sutter; John Regehr

2011-10-01T23:59:59.000Z

150

A switch level fault simulation environment  

Science Conference Proceedings (OSTI)

This paper presents a fault simulation environment which accepts pure switch level or mixed switch/RT level descriptions of the design under test. Switch level fault injection strategies for the stuck-at, transition and logic bridge models are presented. ...

V. Krishnaswamy; J. Casas; T. Tetzlaff

2000-06-01T23:59:59.000Z

151

Representing parameterised fault trees using Bayesian networks  

Science Conference Proceedings (OSTI)

Fault trees are used to model how failures lead to hazards and so to estimate the frequencies of the identified hazards of a system. Large systems, such as a rail network, do not give rise to endless different hazards. Rather, similar hazards arise repeatedly ... Keywords: Bayesian network, fault tree, risk analysis

William Marsh; George Bearfield

2007-09-01T23:59:59.000Z

152

Gas Turbine Fault Diagnosis using Random Forests  

Science Conference Proceedings (OSTI)

In the present paper, Random Forests are used in a critical and at the same time non trivial problem concerning the diagnosis of Gas Turbine blading faults, portraying promising results. Random forests-based fault diagnosis is treated as a Pattern Recognition ...

Manolis Maragoudakis; Euripides Loukis; Panayotis-Prodromos Pantelides

2008-06-01T23:59:59.000Z

153

BASE: Using abstraction to improve fault tolerance  

Science Conference Proceedings (OSTI)

Software errors are a major cause of outages and they are increasingly exploited in malicious attacks. Byzantine fault tolerance allows replicated systems to mask some software errors but it is expensive to deploy. This paper describes a replication ... Keywords: Byzantine fault tolerance, N-version programming, asynchronous systems, proactive recovery, state machine replication

Miguel Castro; Rodrigo Rodrigues; Barbara Liskov

2003-08-01T23:59:59.000Z

154

Numeric simulation of faults in electrical networks  

Science Conference Proceedings (OSTI)

In the paper is presented a virtual simulator for three-phased medium voltage electric circuits. The simulator allows analyzing transient regimes caused by the faults produced in electric distribution networks (simple grounding, double grounding, broken ... Keywords: faults in electric network, numerical simulation, three phased circuits, transient regimes

Toader Dumitru; Haragus Stefan; Blaj Constantin

2009-03-01T23:59:59.000Z

155

INDUCTION MOTOR FAULT DIAGNOSTIC AND MONITORING METHODS  

E-Print Network (OSTI)

INDUCTION MOTOR FAULT DIAGNOSTIC AND MONITORING METHODS by Aderiano M. da Silva, B.S. A Thesis;i Abstract Induction motors are used worldwide as the "workhorse" in industrial applications material. However, induction motor faults can be detected in an initial stage in order to prevent

Povinelli, Richard J.

156

Detect and classify faults using neural nets  

SciTech Connect

The analysis of transmission line faults is essential to the proper performance of the power system. It is required if protective relays are to take the appropriate action and in monitoring the performance of relays, circuit breakers, and other protective and control elements. The detection and classification of transmission line faults is a fundamental component of such fault analysis. Another application of fault analysis is in software packages for automated analysis of digital fault recorder (DFR) files. Recently, such a package, called DFR Assistant, was developed for substation applications. This program can be installed locally in a substation, in which case it is connected directly to the DFR via a high speed parallel link, or it can be installed at a central station, in which case it can be configured to automatically analyze events coming from all DFRs.

Kezunovic, M.; Rikalo, I.

1996-10-01T23:59:59.000Z

157

Modeling and Measurement Constraints in Fault Diagnostics for HVAC Systems  

E-Print Network (OSTI)

in Fault Diagnostics for HVAC Systems Massieh Najafi 1 ,tools for determining HVAC diagnostics, methods todetect faults in HVAC systems are still generally

Najafi, Massieh

2010-01-01T23:59:59.000Z

158

Modeling and simulation of HVAC faults in EnergyPlus  

NLE Websites -- All DOE Office Websites (Extended Search)

simulation of HVAC faults in EnergyPlus Title Modeling and simulation of HVAC faults in EnergyPlus Publication Type Conference Paper Refereed Designation Refereed Year of...

159

Modeling and Measurement Constraints in Fault Diagnostics for...  

NLE Websites -- All DOE Office Websites (Extended Search)

Modeling and Measurement Constraints in Fault Diagnostics for HVAC Systems Title Modeling and Measurement Constraints in Fault Diagnostics for HVAC Systems Publication Type Journal...

160

fault diagnosis of a high voltage transmission line using waveform ...  

E-Print Network (OSTI)

Oct 4, 2013 ... FAULT DIAGNOSIS OF A HIGH VOLTAGE TRANSMISSION LINE USING ... Fault types such as single line to ground, line to line, double line to...

Note: This page contains sample records for the topic "madrid fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

CIFTS: Coordinated Infrastructure for Fault-Tolerant Systems...  

NLE Websites -- All DOE Office Websites (Extended Search)

CIFTS: Coordinated Infrastructure for Fault-Tolerant Systems CIFTS: Coordinated Infrastructure for Fault-Tolerant Systems Current systems software components for large-scale...

162

CIFTS: A Coordinated Infrastructure for Fault-Tolerant Systems...  

NLE Websites -- All DOE Office Websites (Extended Search)

CIFTS: A Coordinated Infrastructure for Fault-Tolerant Systems Title CIFTS: A Coordinated Infrastructure for Fault-Tolerant Systems Publication Type Conference Paper Year of...

163

Automated Fault Location In Smart Distribution Systems  

E-Print Network (OSTI)

Fault location in distribution systems is a critical component of outage management and service restoration, which directly impacts feeder reliability and quality of the electricity supply. Improving fault location methods supports the Department of Energy (DOE) Grid 2030 initiatives for grid modernization by improving reliability indices of the network. Improving customer average interruption duration index (CAIDI) and system average interruption duration index (SAIDI) are direct advantages of utilizing a suitable fault location method. As distribution systems are gradually evolving into smart distribution systems, application of more accurate fault location methods based on gathered data from various Intelligent Electronic Devices (IEDs) installed along the feeders is quite feasible. How this may be done and what is the needed methodology to come to such solution is raised and then systematically answered. To reach this goal, the following tasks are carried out: 1) Existing fault location methods in distribution systems are surveyed and their strength and caveats are studied. 2) Characteristics of IEDs in distribution systems are studied and their impacts on fault location method selection and implementation are detailed. 3) A systematic approach for selecting optimal fault location method is proposed and implemented to pinpoint the most promising algorithms for a given set of application requirements. 4) An enhanced fault location method based on voltage sag data gathered from IEDs along the feeder is developed. The method solves the problem of multiple fault location estimations and produces more robust results. 5) An optimal IED placement approach for the enhanced fault location method is developed and practical considerations for its implementation are detailed.

Lotfifard, Saeed

2011-08-01T23:59:59.000Z

164

An arc fault detection system  

DOE Patents (OSTI)

An arc fault detection system for use on ungrounded or high-resistance-grounded power distribution systems is provided which can be retrofitted outside electrical switchboard circuits having limited space constraints. The system includes a differential current relay that senses a current differential between current flowing from secondary windings located in a current transformer coupled to a power supply side of a switchboard, and a total current induced in secondary windings coupled to a load side of the switchboard. When such a current differential is experienced, a current travels through a operating coil of the differential current relay, which in turn, opens an upstream circuit breaker located between the switchboard and a power supply to remove the supply of power to the switchboard.

Jha, Kamal N.

1997-12-01T23:59:59.000Z

165

Fault diagnosis using substation computer  

SciTech Connect

A number of substation integrated control and protection systems (ICPS) are being developed around the world, where the protective relaying, control, and monitoring functions of a substation are implemented using microprocessors. In this design, conventional relays and control devices are replaced by clusters of microprocessors, interconnected by multiplexed digital communication channels using fibre optic, twisted wire pairs or coaxial cables. The ICPS incorporates enhanced functions of value to the utility and leads to further advancement of the automation of transmission substations. This paper presents an automated method of fault diagnosis which can be incorporated in the station computer of an integrated control and protection system. The effectiveness of this method is demonstrated using a transmission-level substation as an example.

Jeyasurya, B. (Indian Inst. of Tech., Bombay (India)); Venkata, S.S. (Washington Univ., Seattle, WA (USA). Dept. of Electrical Engineering); Vadari, S.V. (ESCA Corp., Bellevue, WA (USA)); Postforoosh, J. (T and D. Protection Group, Puget Sound Power and Light, Bellevue, WA (US))

1990-04-01T23:59:59.000Z

166

WRF/Chem-MADRID: Incorporation of an Improved Aerosol Module into WRF/Chem and Its Initial Application to the TexAQS2000 Episode  

SciTech Connect

The Model of Aerosol Dynamics, Reaction, Ionization and Dissolution (MADRID) with three improved gas/particle mass transfer approaches (i.e., bulk equilibrium (EQUI), hybrid (HYBR), and kinetic (KINE)) has been incorporated into the Weather Research and Forecast/Chemistry Model (WRF/Chem) (referred to as WRF/Chem-MADRID) and evaluated with a 5-day episode from the 2000 Texas Air Quality Study (TexAQS2000). WRF/Chem-MADRID demonstrates an overall good skill in simulating surface/aloft meteorological parameters and chemical concentrations, tropospheric O3 residuals, and aerosol optical depths. The discrepancies can be attributed to inaccuracies in meteorological predictions (e.g., overprediction in mid-day boundary layer height), inaccurate total emissions or their hourly variations (e.g., HCHO, olefins, other inorganic aerosols), and uncertainties in initial and boundary conditions for some species (e.g., other inorganic aerosols and O3) at surface and aloft. Major differences in the results among the three gas/particle mass transfer approaches occur over coastal areas, where EQUI predicts higher PM2.5 than HYBR and KINE due to improperly redistributing condensed nitrate from chloride depletion process to fine PM mode. The net direct, semi-direct, and indirect effects of PM2.5 decreased domain wide shortwave radiation by 11.2-14.4 W m-2 (or 4.1-5.6%), decreased near-surface temperature by 0.06-0.14 C (or 0.2-0.4%), led to 125 to 796 cm-3 cloud condensation nuclei at a supersaturation of 0.1%, produced cloud droplet numbers as high as 2064 cm-3, and reduced domain wide mean precipitation by 0.22-0.59 mm day-1.

Zhang, Yang; Pan, Ying; Wang, K.; Fast, Jerome D.; Grell, G. A.

2010-09-17T23:59:59.000Z

167

Subduction Zone | Open Energy Information  

Open Energy Info (EERE)

Subduction Zone Subduction Zone Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Subduction Zone Dictionary.png Subduction Zone: A tectonic process in which one tectonic plate is forced beneath another and sinks into the mantle as the plates converge Other definitions:Wikipedia Reegle Tectonic Settings List of tectonic settings known to host modern geothermal systems: Extensional Tectonics Subduction Zone Rift Zone Hot Spot Non-Tectonic Strike-Slip A classic cartoon illustrating a typical simplified subduction zone. http://www.columbia.edu/~vjd1/subd_zone_basic.htm Subduction zones occur where one tectonic plate is pulled under another. Most often the subducting plate is oceanic crust and contains many hydrous minerals. As the oceanic plate subducts it dewaters into the mantle,

168

Cooperative application/OS DRAM fault recovery.  

Science Conference Proceedings (OSTI)

Exascale systems will present considerable fault-tolerance challenges to applications and system software. These systems are expected to suffer several hard and soft errors per day. Unfortunately, many fault-tolerance methods in use, such as rollback recovery, are unsuitable for many expected errors, for example DRAM failures. As a result, applications will need to address these resilience challenges to more effectively utilize future systems. In this paper, we describe work on a cross-layer application/OS framework to handle uncorrected memory errors. We illustrate the use of this framework through its integration with a new fault-tolerant iterative solver within the Trilinos library, and present initial convergence results.

Ferreira, Kurt Brian; Bridges, Patrick G. (University of New Mexico, Albuquerque, NM); Heroux, Michael Allen; Hoemmen, Mark; Brightwell, Ronald Brian

2012-05-01T23:59:59.000Z

169

Mechanical Models of Fault-Related Folding  

SciTech Connect

The subject of the proposed research is fault-related folding and ground deformation. The results are relevant to oil-producing structures throughout the world, to understanding of damage that has been observed along and near earthquake ruptures, and to earthquake-producing structures in California and other tectonically-active areas. The objectives of the proposed research were to provide both a unified, mechanical infrastructure for studies of fault-related foldings and to present the results in computer programs that have graphical users interfaces (GUIs) so that structural geologists and geophysicists can model a wide variety of fault-related folds (FaRFs).

Johnson, A. M.

2003-01-09T23:59:59.000Z

170

Neural Fault Diagnosis and Fuzzy Fault Control for a Complex Dynamic System  

E-Print Network (OSTI)

Fault diagnosis has become an issue of primary importance in modern process automation as it provides the prerequisites for the task of fault detection. The ability to detect the faults is essential to improve reliability and security of a complex control system. Parameter estimation methods, state observation schemes, statistical likelihood ratio tests, rule-based expert system reasoning, pattern recognition techniques, and artificial neural network approaches are the most common methodologies developed actively during recent years. In this paper, we describe a completed feasibility study demonstrating the merit of employing pattern recognition and an artificial neural network for fault diagnosis through back propagation learning algorithm and making the use of fuzzy approximate reasoning for fault control via parameter changes in a dynamic system. As a test case, a complex magnetic levitation vehicle (MLV) system is studied. Analytical fault symptoms are obtained by system dynamics m...

Ching-yu Tyan; Paul P. Wang; Dennis R. Bahler

1995-01-01T23:59:59.000Z

171

Quantification of Priority-OR gates in temporal fault trees  

Science Conference Proceedings (OSTI)

Fault Tree Analysis has been used in reliability engineering for many decades and has seen various modifications to enable it to analyse fault trees with dynamic and temporal gates so it can incorporate sequential failure in its analysis. Pandora is ... Keywords: Markov chains, Monte Carlo, Pandora, dynamic fault trees, fault trees, safety

Ernest Edifor; Martin Walker; Neil Gordon

2012-09-01T23:59:59.000Z

172

Online fault detection and tolerance for photovoltaic energy harvesting systems  

Science Conference Proceedings (OSTI)

Photovoltaic energy harvesting systems (PV systems) are subject to PV cell faults, which decrease the efficiency of PV systems and even shorten the PV system lifespan. Manual PV cell fault detection and elimination are expensive and nearly impossible ... Keywords: fault detection, fault tolerance, photovoltaic panel reconfiguration, photovoltaic system

Xue Lin; Yanzhi Wang; Di Zhu; Naehyuck Chang; Massoud Pedram

2012-11-01T23:59:59.000Z

173

A transmission line fault locator based on Elman recurrent networks  

Science Conference Proceedings (OSTI)

In this paper, a transmission line fault location model which is based on an Elman recurrent network (ERN) has been presented for balanced and unbalanced short circuit faults. All fault situations with different inception times are implemented on a 380-kV ... Keywords: Elman networks, Fault location, Transmission lines, Wavelet transform

Sami Ekici; Selcuk Yildirim; Mustafa Poyraz

2009-01-01T23:59:59.000Z

174

Fault intersections and hybrid transform faults in the southern Salton Trough geothermal area, Baja California, Mexico  

DOE Green Energy (OSTI)

Analysis of 55 wells drilled at the Cerro Prieto Geothermal Field and a suite of geological and geophysical studies throughout the southern Salton Trough from the Mexican-United States border to the Gulf of California clarify two concepts important to geothermal development: (1) increased natural convective fluid flow and better permeability should occur at intersecting faults both regionally and within a producing field, and (2) the Cerro Prieto and Imperial faults are best conceived of as hybrid types having features of both San Andreas style wrench faults and oceanic tranform faults.

Vonder Haar, S.; Puente Cruz, I.

1979-07-01T23:59:59.000Z

175

Fault Detection, Location, Isolation and Reconnection in ...  

A University of Colorado research team led by Jae-Do Park has developed a fault detection, location and isolation scheme for a low-voltage DC-bus microgrid system, ...

176

Fault tolerance for holonomic quantum computation  

E-Print Network (OSTI)

We review an approach to fault-tolerant holonomic quantum computation on stabilizer codes. We explain its workings as based on adiabatic dragging of the subsystem containing the logical information around suitable loops along which the information remains protected.

Ognyan Oreshkov; Todd A. Brun; Daniel A. Lidar

2013-12-01T23:59:59.000Z

177

Building Technologies Office: Climate Zones  

NLE Websites -- All DOE Office Websites (Extended Search)

Climate Zones to Climate Zones to someone by E-mail Share Building Technologies Office: Climate Zones on Facebook Tweet about Building Technologies Office: Climate Zones on Twitter Bookmark Building Technologies Office: Climate Zones on Google Bookmark Building Technologies Office: Climate Zones on Delicious Rank Building Technologies Office: Climate Zones on Digg Find More places to share Building Technologies Office: Climate Zones on AddThis.com... About Take Action to Save Energy Partner With DOE Activities Solar Decathlon Building America Research Innovations Research Tools Building Science Education Climate-Specific Guidance Solution Center Partnerships Meetings Publications Home Energy Score Home Performance with ENERGY STAR Better Buildings Neighborhood Program Challenge Home Guidelines for Home Energy Professionals

178

Rift Zone | Open Energy Information  

Open Energy Info (EERE)

Rift Zone Rift Zone Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Rift Zone Dictionary.png Rift Zone: A divergent plate boundary within a continent Other definitions:Wikipedia Reegle Tectonic Settings List of tectonic settings known to host modern geothermal systems: Extensional Tectonics Subduction Zone Rift Zone Hot Spot Non-Tectonic Strike-Slip The Rio Grande Rift exemplifies rift zone tectonics - increased volcanic activity and the formation of graben structures (reference: science-art.com) Rift valleys occur at divergent plate boundaries, resulting in large graben structures and increased volcanism. The East African Rift is an example of a continental rift zone with increased volcanism, while the Atlantic's spreading Mid-Ocean Ridge is host to an enormous amount of geothermal

179

The Enterprise Zone (Rhode Island)  

Energy.gov (U.S. Department of Energy (DOE))

The Enterprise Zone offers tax incentives to business expanding their workforce by 5% at facilities in designated enterprise zones. The tax credit is equal to 50% of the annual wages paid to a new...

180

Radiant zone heated particulate filter  

DOE Patents (OSTI)

A system includes a particulate matter (PM) filter including an upstream end for receiving exhaust gas and a downstream end. A radiant zoned heater includes N zones, where N is an integer greater than one, wherein each of the N zones includes M sub-zones, where M is an integer greater than or equal to one. A control module selectively activates at least a selected one of the N zones to initiate regeneration in downstream portions of the PM filter from the one of the N zones, restricts exhaust gas flow in a portion of the PM filter that corresponds to the selected one of the N zones, and deactivates non-selected ones of the N zones.

Gonze, Eugene V [Pinckney, MI

2011-12-27T23:59:59.000Z

Note: This page contains sample records for the topic "madrid fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

CO2 Emissions - Panama Canal Zone  

NLE Websites -- All DOE Office Websites (Extended Search)

Panama Canal Zone Graphics CO2 Emissions from Panama Canal Zone Data graphic Data CO2 Emissions from Panama Canal Zone...

182

Transition Zone Geothermal Region | Open Energy Information  

Open Energy Info (EERE)

Transition Zone Geothermal Region (Redirected from Transition Zone) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Transition Zone Geothermal Region edit Details...

183

A Closer Look at Salt, Faults, and Gas in the Northwestern Gulf of Mexico with 2-D Multichannel Seismic Data  

E-Print Network (OSTI)

The sedimentary wedge of the northern Gulf of Mexico is extensively deformed and faulted by salt tectonics. Industry 2-D multichannel seismic data covering a large area (33,800 km2) of the lower Texas continental slope [96 degrees 40'- 93 degrees 40'W; 27 degrees 10N - 26 degrees N] were examined to evaluate the interplay of salt, faults and gas. Seismic interpretation revealed the study area has two different styles of faulting and two different types of salt bodies that vary east to west. The eastern region of the study area has a thin sedimentary section and a massive, nearly continuous salt sheet characterized by minibasins and local salt highs. Faulting in this area appears to be the result of salt tectonism. The western region of the study area has a thick sedimentary wedge, and a few isolated salt diapirs. Long, linear faults are parallel to slope and imply some degree of gravitation sliding. The difference in faulting styles and salt bodies can be attributed to different depositional environments, different styles and amounts of sediment loading and different amounts of salt initially deposited. While there is a widespread occurrence of gas throughout the study area, little evidence of continuous bottom simulating reflectors (BSRs), a widely accepted geophysical indicator of gas hydrate, has been found. The gas hydrate stability zone (GHSZ) was modeled to provide information on the thickness and variability of the stability zone, and provide a baseline in a search for BSRs. The dataset was analyzed for multiple seismic expressions of BSRs, however only a few small and isolated examples were found. Potential fluid escape structures were seen in the seismic data. Despite the great number of potential features found in the seismic data only seven active seeps were found in a seep study by I. R. MacDonald. Seeps were seen in far less abundance than the number of seeps found offshore Louisiana. This may imply a lack of source offshore Texas.

Nemazi, Leslie A.

2010-05-01T23:59:59.000Z

184

Measuring and Modeling Fault Density for Plume-Fault Encounter Probability Estimation  

Science Conference Proceedings (OSTI)

Emission of carbon dioxide from fossil-fueled power generation stations contributes to global climate change. Storage of this carbon dioxide within the pores of geologic strata (geologic carbon storage) is one approach to mitigating the climate change that would otherwise occur. The large storage volume needed for this mitigation requires injection into brine-filled pore space in reservoir strata overlain by cap rocks. One of the main concerns of storage in such rocks is leakage via faults. In the early stages of site selection, site-specific fault coverages are often not available. This necessitates a method for using available fault data to develop an estimate of the likelihood of injected carbon dioxide encountering and migrating up a fault, primarily due to buoyancy. Fault population statistics provide one of the main inputs to calculate the encounter probability. Previous fault population statistics work is shown to be applicable to areal fault density statistics. This result is applied to a case study in the southern portion of the San Joaquin Basin with the result that the probability of a carbon dioxide plume from a previously planned injection had a 3% chance of encountering a fully seal offsetting fault.

Jordan, P.D.; Oldenburg, C.M.; Nicot, J.-P.

2011-05-15T23:59:59.000Z

185

Liquid zone seal  

DOE Patents (OSTI)

A seal assembly that provides a means for establishing multiple pressure zones within a system. The seal assembly combines a plate extending from the inner wall of a housing or inner enclosure that intersects with and is immersed in the fluid contained in a well formed in a tray contained within the enclosure. The fluid is a low vapor pressure oil, chemically inert and oxidation resistant. The use of a fluid as the sealing component provides a seal that is self-healing and mechanically robust not subject to normal mechanical wear, breakage, and formation of cracks or pinholes and decouples external mechanical vibrations from internal structural members.

Klebanoff, Leonard E. (Dublin, CA)

2001-01-01T23:59:59.000Z

186

A fault location approach for fuzzy fault section estimation on radial distribution feeders  

E-Print Network (OSTI)

Locating the faulted section of a distribution system is a difficult task because of lack of accurate system models and the presence of uncertainty in the data used for estimating the fault section. Many of the methods used to account for the uncertainty use fuzzy logic techniques to estimate bounds of possibility of the input data and calculated quantities, or probabilistic modeling of the input data to estimate the likelihood of the location of the fault on a particular section of the feeder. Heuristic knowledge of control center dispatchers has also been used for uncertainty management. This thesis presents the design and implementation of a phase selector algorithm and a fault distance algorithm for use in an automated modular scheme for fault section estimation on radial distribution systems. These two algorithms will be executed in combination with two other fault location algorithms. The scheme is executed using the data record of an abnormal event in a three-stage scheme. The phase selector algorithm was used to obtain event-phase possibility values representing the possibility of involvement of each of the phases and the neutral in an event. A section-event possibility value that indicated the possibility that a section of the feeder was involved in the fault was evaluated using the event-phase possibility values and line section phase topology information. The fault distance algorithm was used to eliminate sections of the feeder that were not likely to be possible faulted section candidates by assuming a bolted fault and estimating its location. Each line section was assigned a fault possibility value of zero or one according to its location relative to the location of the fault. The phase selector algorithm was tested using real data measured at feeder substations and the fault distance algorithm was tested using data obtained by staging faults on a model of an overhead feeder using EMTP/ATP simulation. The results obtained from the tests were promising. A simple illustration of the combination of the results of the two algorithms is given. The result of this combination shows the potential of the simultaneous use of the two algorithms.

Andoh, Kwame Sarpong

2000-01-01T23:59:59.000Z

187

Holocene surface faulting along the west flank of the Santa Rosa Range (Nevada-Oregon) and the possible northern extension of the Central Nevada Seismic Belt  

Science Conference Proceedings (OSTI)

The 130 km long Santa Rose Range fault system extends northward from a point about 70 km north of the 1915 Pleasant Valley earthquake fault ruptures to Blue Mountain Pass, Oregon. The authors have examined 1:12,000 low-sun-angle aerial photographs and conducted surveys of scarp morphology to investigate the neotectonic evolution and paleoseismicity of this possible northern extension of the Central Nevada Seismic Belt. Two adjoining segments of the fault zone are separated by a right step in the range-front and apparent absence of Holocene scarps. Each segment records evidence of a Holocene faulting event. The southern 31 km segment between Frey Ranch and the Willow Creek fan shows both small scarps (Valley and larger scarps which oversteepen the base of the adjacent range-front to slopes of 20[degree] to 24[degree]. The northern 42 km segment between Flat Creek and Oregon Canyon Creek shows a recent offset which rejuvenates older (pre-Lahontan) fault scarps and also cuts Holocene terraces along the base of the piedmont pediment. Based on preliminary morphometric data, the maximum vertical displacement (3--4 m) and age of the faulting (early Holocene) are similar in both segments but it is not known whether both segments ruptured contemporaneously. Except for the lack of large historical surface faulting the main neotectonic and geomorphic features of the Santa Rose Range fault zone are similar to that of the Dixie Valley and Pleasant Valley regions of the Central Nevada Seismic Belt. Hence, the occurrence of a large earthquake rupture along this range-front in the near future should not be viewed as a surprise.

Michetti, A.M. (CNR/GNDT, Rome (Italy) Univ. of Nevada, Reno, NV (United States). Center for Neotectonic Studies); Wesnousky, S.G. (Univ. of Nevada, Reno, NV (United States). Center for Neotectonic Studies)

1993-04-01T23:59:59.000Z

188

Fault Locating, Prediction and Protection (FLPPS)  

Science Conference Proceedings (OSTI)

One of the main objectives of this DOE-sponsored project was to reduce customer outage time. Fault location, prediction, and protection are the most important aspects of fault management for the reduction of outage time. In the past most of the research and development on power system faults in these areas has focused on transmission systems, and it is not until recently with deregulation and competition that research on power system faults has begun to focus on the unique aspects of distribution systems. This project was planned with three Phases, approximately one year per phase. The first phase of the project involved an assessment of the state-of-the-art in fault location, prediction, and detection as well as the design, lab testing, and field installation of the advanced protection system on the SCE Circuit of the Future located north of San Bernardino, CA. The new feeder automation scheme, with vacuum fault interrupters, will limit the number of customers affected by the fault. Depending on the fault location, the substation breaker might not even trip. Through the use of fast communications (fiber) the fault locations can be determined and the proper fault interrupting switches opened automatically. With knowledge of circuit loadings at the time of the fault, ties to other circuits can be closed automatically to restore all customers except the faulted section. This new automation scheme limits outage time and increases reliability for customers. The second phase of the project involved the selection, modeling, testing and installation of a fault current limiter on the Circuit of the Future. While this project did not pay for the installation and testing of the fault current limiter, it did perform the evaluation of the fault current limiter and its impacts on the protection system of the Circuit of the Future. After investigation of several fault current limiters, the Zenergy superconducting, saturable core fault current limiter was selected for installation. Because of some testing problems with the Zenergy fault current limiter, installation was delayed until early 2009 with it being put into operation on March 6, 2009. A malfunction of the FCL controller caused the DC power supply to the superconducting magnet to be turned off. This inserted the FCL impedance into the circuit while it was in normal operation causing a voltage resonance condition. While these voltages never reached a point where damage would occur on customer equipment, steps were taken to insure this would not happen again. The FCL was reenergized with load on December 18, 2009. A fault was experienced on the circuit with the FCL in operation on January 14, 2010. The FCL operated properly and reduced the fault current by about 8%, what was expected from tests and modeling. As of the end of the project, the FCL was still in operation on the circuit. The third phase of the project involved the exploration of several advanced protection ideas that might be at a state where they could be applied to the Circuit of the Future and elsewhere in the SCE electrical system. Based on the work done as part of the literature review and survey, as well as a number of internal meetings with engineering staff at SCE, a number of ideas were compiled. These ideas were then evaluated for applicability and ability to be applied on the Circuit of the Future in the time remaining for the project. Some of these basic ideas were implemented on the circuit including measurement of power quality before and after the FCL. It was also decided that we would take what was learned as part of the Circuit of the Future work and extend it to the next generation circuit protection for SCE. Also at this time, SCE put in a proposal to the DOE for the Irvine Smart Grid Demonstration using ARRA funding. SCE was successful in obtaining funding for this proposal, so it was felt that exploration of new protection schemes for this Irvine Smart Grid Demonstration would be a good use of the project resources. With this in mind, a protection system that uses fault interrupting switches, hi

Yinger, Robert, J.; Venkata, S., S.; Centeno, Virgilio

2010-09-30T23:59:59.000Z

189

Fast Fault Recovery in Switched Networks for Carrying IP Telephony Traffic.  

E-Print Network (OSTI)

?? One of the most parts of VOIP management is fault management and, in having a good fault management, finding good mechanisms to detect faults (more)

Eisazadeh, Ali Akbar

2010-01-01T23:59:59.000Z

190

Madrid Daylighting Report  

NLE Websites -- All DOE Office Websites (Extended Search)

REPORTS - Daylighting Quality Page REPORTS - Daylighting Quality Page 1 of 2 DAYLIGHTING QUALITY 1) NATURAL LIGHTING The main criteria for interior design is leading the user from darkness toward daylight. For this reason, the main source of daylighting is the south wall. Moreover, a whole part of the house may be unfolded, letting an internal open courtyard provide a touch of natural environment into the house. Small fixed windows with steel sash and frames are also strategically located to allow the user to get a beam of the morning or sunset light -even though such orientations are inconvenient from a bioclimatic point of view-, as well as to see the outside while working or having lunch. In most cases, glass is covered with shutters and stainless steel frames fitting woven wire

191

Madrid Electric Lighting Report  

NLE Websites -- All DOE Office Websites (Extended Search)

Electric Lighting Quality Page 1 of 2 ELECTRIC LIGHTING QUALITY MAGIC BOX is a versatile home. Its design allows to change the room size by opening and closing the movable walls...

192

Magnesium Workshop Madrid 2013  

Science Conference Proceedings (OSTI)

Nov 15, 2012 ... First-Principles Investigation of Mg-Rare Earth Precipitates and LPSO ... and Tube Warm Forming: from Incremental to Electromagnetic Forming.

193

Madrid Hot Water Report  

NLE Websites -- All DOE Office Websites (Extended Search)

Comprehensive Assessment of Hot Water System Page 1 of 2 HOT WATER SYSTEM In general, the plumbing system in MAGIC BOX is designed to concentrate all devices, be they storage,...

194

Lithology, fault displacement, and origin of secondary calcium carbonate and opaline silica at Trenches 14 and 14D on the Bow Ridge Fault at Exile Hill, Nye County, Nevada  

SciTech Connect

Yucca Mountain, a proposed site for a high-level nuclear-waste repository, is located in southern Nevada, 20 km east of Beatty, and adjacent to the southwest comer of the Nevada Test Site (NTS) (fig. 1). Yucca Mountain is located within the Basin and Range province of the western United States. The climate is semiarid, and the flora is transitional between that of the Mojave Desert to the south and the Great Basin Desert to the north. As part of the evaluation, hydrologic conditions, especially water levels, of Yucca Mountain and vicinity during the Quaternary, and especially the past 20,000 years, are being characterized. In 1982, the US Geological Survey, in cooperation with the US Department of Energy (under interagency agreement DE-A104-78ET44802), excavated twenty-six bulldozer and backhoe trenches in the Yucca Mountain region to evaluate the nature and frequency of Quaternary faulting (Swadley and others, 1984). The trenches were oriented perpendicular to traces of suspected Quaternary faults and across projections of known bedrock faults into Quaternary deposits. Trench 14 exposes the Bow Ridge Fault on the west side of Exile Hill. Although the original purpose of the excavation of trench 14 was to evaluate the nature and frequency of Quaternary faulting on the Bow Ridge Fault, concern arose as to whether or not the nearly vertical calcium carbonate (the term ``carbonate`` in this study refers to calcium carbonate) and opaline silica veins in the fault zone were deposited by ascending waters (ground water). These veins resemble in gross morphology veins commonly formed by hydrothermal processes.

Taylor, E.M.; Huckins, H.E.

1995-02-01T23:59:59.000Z

195

Climate Zone 5C | Open Energy Information  

Open Energy Info (EERE)

Climate Zone 5C Jump to: navigation, search A type of climate defined in the ASHRAE 169-2006 standard consisting of Climate Zone Number 5 and Climate Zone Subtype C. Climate Zone...

196

History and Results of Surface Exploration in the Kilauea East Rift Zone |  

Open Energy Info (EERE)

History and Results of Surface Exploration in the Kilauea East Rift Zone History and Results of Surface Exploration in the Kilauea East Rift Zone Jump to: navigation, search OpenEI Reference LibraryAdd to library Conference Paper: History and Results of Surface Exploration in the Kilauea East Rift Zone Abstract Government-funded surveys of the Kilauea East Rift Zone have resulted in a wealth of geophysical and geochemical data from an active volcanic area. All data are clearly of academic interest; Hawaii was used as a testing ground for various geophysical methods in the early days of geothermal exploration. Some surveys, such as gravity and magnetic, are useful a regional perspective for determining broad structural trends and grossly identifying magmatic intrusions. Seismic data are currently being used for a more sitespecific purpose: to determine fault locations and geometries.

197

VCSEL fault location apparatus and method  

DOE Patents (OSTI)

An apparatus for locating a fault within an optical fiber is disclosed. The apparatus, which can be formed as a part of a fiber-optic transmitter or as a stand-alone instrument, utilizes a vertical-cavity surface-emitting laser (VCSEL) to generate a test pulse of light which is coupled into an optical fiber under test. The VCSEL is subsequently reconfigured by changing a bias voltage thereto and is used as a resonant-cavity photodetector (RCPD) to detect a portion of the test light pulse which is reflected or scattered from any fault within the optical fiber. A time interval .DELTA.t between an instant in time when the test light pulse is generated and the time the reflected or scattered portion is detected can then be used to determine the location of the fault within the optical fiber.

Keeler, Gordon A. (Albuquerque, NM); Serkland, Darwin K. (Albuquerque, NM)

2007-05-15T23:59:59.000Z

198

Breathing zone air sampler  

DOE Patents (OSTI)

A sampling apparatus is provided which comprises a sampler for sampling air in the breathing zone of a wearer of the apparatus and a support for the sampler preferably in the form of a pair of eyeglasses. The sampler comprises a sampling assembly supported on the frame of the eyeglasses and including a pair of sample transport tubes which are suspended, in use, centrally of the frame so as to be disposed on opposite sides of the nose of the wearer and which each include an inlet therein that, in use, is disposed adjacent to a respective nostril of the nose of the wearer. A filter holder connected to sample transport tubes supports a removable filter for filtering out particulate material in the air sampled by the apparatus. The sample apparatus is connected to a pump for drawing air into the apparatus through the tube inlets so that the air passes through the filter.

Tobin, John (Bethel Park, PA)

1989-01-01T23:59:59.000Z

199

Western Renewable Energy Zones (Presentation)  

DOE Green Energy (OSTI)

This presentation summarizes recent developments and trends pertaining to competitive renewable energy zones, transmission planning and the integration of renewable generation resources.

Hein, J.

2011-06-01T23:59:59.000Z

200

DOE Solar Decathlon: Comfort Zone  

NLE Websites -- All DOE Office Websites (Extended Search)

Decathlon Comfort Zone Contest, teams design their houses to keep temperature and humidity steady, uniform, and comfortable. Full points are awarded for maintaining narrow...

Note: This page contains sample records for the topic "madrid fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Interfacial Transition Zone Bibliography Database  

Science Conference Proceedings (OSTI)

... Saito, M., and Kawamura, M., Effect of Fly Ash and Slag on the Interfacial Zone Between Cement and Aggregate , in ACI SP 114: Fly Ash, Silica ...

2013-05-14T23:59:59.000Z

202

Development of Hydrologic Characterization Technology of Fault Zones -- Phase I, 2nd Report  

E-Print Network (OSTI)

thus far, but to conduct investigation of possible abutmentNUMO when it conducts preliminary investigations at yet-to-Design and plan work Conduct surface investigation activity

Karasaki, Kenzi

2010-01-01T23:59:59.000Z

203

Development of a Hydrologic Characterization Technology for Fault Zones Phase II 2nd Report  

E-Print Network (OSTI)

sample, (b) Dieselstandard (c) motor oil, and (d) crude oilc) and (d) are the diesel, motor oil, and crude oil standardto be a mixture of diesel and motor oil. One alternative

Karasaki, Kenzi

2013-01-01T23:59:59.000Z

204

Development of a Hydrologic Characterization Technology for Fault Zones Phase II 2nd Report  

E-Print Network (OSTI)

deposition of the Monterey Formation and related siliceousJ.C.Jr, eds.The Monterey Formation and related siliceousin the Miocene Monterey Formation, Santa Barbara coastal

Karasaki, Kenzi

2013-01-01T23:59:59.000Z

205

Development of a Hydrologic Characterization Technology for Fault Zones Phase II 2nd Report  

E-Print Network (OSTI)

2-2 Original electrical resistivity survey interpretationnatural gamma, electrical resistivity, SP, televiewer,2-1 2.2 Electrical Resistivity Survey (ER-

Karasaki, Kenzi

2013-01-01T23:59:59.000Z

206

Development of Hydrologic Characterization Technology of Fault Zones -- Phase I, 2nd Report  

E-Print Network (OSTI)

1, 2 and 3 for electrical resistivity and seismic reflection89 Figure 3-36. Electrical resistivity profiles for Line 1(40. Superimposed plot of electrical resistivity and seismic

Karasaki, Kenzi

2010-01-01T23:59:59.000Z

207

Geometry of Cenozoic extensional faulting: Dixie Valley, Nevada | Open  

Open Energy Info (EERE)

Geometry of Cenozoic extensional faulting: Dixie Valley, Nevada Geometry of Cenozoic extensional faulting: Dixie Valley, Nevada Jump to: navigation, search OpenEI Reference LibraryAdd to library Journal Article: Geometry of Cenozoic extensional faulting: Dixie Valley, Nevada Abstract Precise definition of geometric relationships between individual basins and ranges may help to reveal the mechanical processes of Basin and Range Cenozoic extensional faulting at depth. Previous studies have attempted to identify simple horsts and grabens, tilted crustal blocks with planar faulting, or tilted crustal blocks with listric faulting in the shallow crust. Normal faults defining these crustal blocks may root (1) individually in the ductile lower crust, (2) in regional or local low-angle detachment faults, or (3) in igneous intrusions or decoupling surfaces

208

Synthesis and evaluation of fault-tolerant quantum computer architectures  

E-Print Network (OSTI)

Fault-tolerance is the cornerstone of practical, large-scale quantum computing, pushed into its prominent position with heroic theoretical efforts. The fault-tolerance threshold, which is the component failure probability ...

Cross, Andrew W. (Andrew William), 1979-

2005-01-01T23:59:59.000Z

209

Scalable Distributed Consensus to Support MPI Fault Tolerance  

Science Conference Proceedings (OSTI)

As system sizes increase, the amount of time in which an application can run without experiencing a failure decreases. Exascale applications will need to address fault tolerance. In order to support algorithm-based fault tolerance, communication libraries ...

Darius Buntinas

2012-05-01T23:59:59.000Z

210

Rough neural fault classification for hvdc power systems  

Science Conference Proceedings (OSTI)

This Ph.D. thesis proposes an approach to classify faults that commonly occur in a High Voltage Direct Current (HVDC) power system. These faults are distributed throughout the entire HVDC system. The most recently published techniques for power system ...

Liting Han

2008-01-01T23:59:59.000Z

211

High-level test synthesis for delay fault testability  

Science Conference Proceedings (OSTI)

A high-level test synthesis (HLTS) method targeted for delay fault testability is presented. The proposed method, when combined with hierarchical test pattern generation for embedded modules, guarantees 100% delay test coverage for detectable faults ...

Sying-Jyan Wang; Tung-Hua Yeh

2007-04-01T23:59:59.000Z

212

MODELING AND SIMULATION OF HVAC FAULTS IN ENERGYPLUS  

E-Print Network (OSTI)

sensor faults, Energy and Buildings. 42(4). April 2010.faults in buildings. Energy and Buildings. 42(1). Januaryon the DOE-2 model, Energy and Buildings. 21(2). 1994, Pages

Basarkar, Mangesh

2013-01-01T23:59:59.000Z

213

Stability of Distributed Algorithms in the Face of Incessant Faults  

Science Conference Proceedings (OSTI)

For large distributed systems built from inexpensive components, one expects to see incessant failures. This paper proposes two models for such faults and analyzes two well-known self-stabilizing algorithms under these fault models. For a small number ...

Robert E. Lee Deville; Sayan Mitra

2009-11-01T23:59:59.000Z

214

Design and Evaluation of Hybrid Fault-Detection Systems  

Science Conference Proceedings (OSTI)

As chip densities and clock rates increase, processors are becoming more susceptible to transient faults that can affect program correctness. Up to now, system designers have primarily considered hardware-only and software-only fault-detection mechanisms ...

George A. Reis; Jonathan Chang; Neil Vachharajani; Ram Rangan; David I. August; Shubhendu S. Mukherjee

2005-06-01T23:59:59.000Z

215

Two-person control administration: preventing administration faults through duplication  

Science Conference Proceedings (OSTI)

Modern computing systems are complex and difficult to administer, making them more prone to system administration faults. Faults can occur simply due to mistakes in the process of administering a complex system. These mistakes can make the system insecure ...

Shaya Potter; Steven M. Bellovin; Jason Nieh

2009-11-01T23:59:59.000Z

216

Fault Current Limiters (FCL) Fact Sheet | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

& Publications An Assessment of Fault Current Limiter Testing Requirements Superconductivity Program Overview Superconductivity for Electric Systems: 2008 Annual Peer Review...

217

EPRI Fault Current Management Guidebook, Sixth Edition (Maroon Book)  

Science Conference Proceedings (OSTI)

This document is an update of the document Fault Current Management Guidebook, Fifth Edition on fault current effects and management in transmission and distribution systems. This guide is intended to be a snapshot of available references, information, and literature on the effects of high fault current on a number of power system components and various available and emerging fault-current-limiting technologies.Results and FindingsDue to increased ...

2012-12-31T23:59:59.000Z

218

Underground Cable Fault Location Reference and Application Guide  

Science Conference Proceedings (OSTI)

This report summarizes underground cable fault location methods and details the application of the methods for transmission and distribution cable systems. It summarizes both terminal location and tracer location methods that can be applied to transmission and distribution cable systems. The report is an update to a summary of fault location methods. It provides practical technical material in the art and science of locating cable faults, including a description of common fault location instruments and p...

2011-12-23T23:59:59.000Z

219

Understanding Fault Characteristics of Inverter-Based Distributed Energy Resources  

SciTech Connect

This report discusses issues and provides solutions for dealing with fault current contributions from inverter-based distributed energy resources.

Keller, J.; Kroposki, B.

2010-01-01T23:59:59.000Z

220

Fault Diagnosis of Transformer Based on Probabilistic Neural Network  

Science Conference Proceedings (OSTI)

In order to improve the correct rate of transformer fault diagnosis based on three-ratio method of traditional dissolved gas analysis (DGA), a novel intelligent transformer fault diagnosis method based on both DGA and probabilistic neural network (PNN) ... Keywords: transformer fault diagnosis, probabilistic neural network (PNN), improved three-ratio method

Li Song; Li Xiu-ying; Wang Wen-xu

2011-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "madrid fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

New Burnside Anticline: part of Fluorspar area fault complex  

SciTech Connect

Field mapping in the Abbott Formation and examination of topographic lineaments in the Creal Springs, Stonefort, Eddyville, and Harrisburg Quadrangles (southeastern Illinois) reveal the New Burnside anticline and its northeastern extension, the Stonefort anticline to be a single, extensively faulted structure. Interpretation of this evidence also leads to the conclusion that this is a fault-block structure rather than an anticline. Trending notheast-southwest, the structure seems to be the northwesternmost extent of the Fluorspar Area fault complex. The authors found evidence for two episodes of faulting. The first involved northeast-trending, high-angle faults similar to those in the known Fluorspar complex to the southeast. Faults on the northeast (Stonefort antilcine) step down toward the center of the structure, forming a graben. Vertical movement also occurred to the southwest (New Burnside anticline), but the structure in this vicinity is a horst with some blocks tilted. As with other faults in the Fluorspar complex, horizontal slickensides are present locally. The second episode of movement occurred along northwest-southeast-trending strike-slip faults that offset the northeast-trending high-angle faults. This second phase of faulting may correspond with previously reported reactivation of northwest-trending faults elsewhere in the Fluorspar Area fault complex.

Jacobson, R.J.; Trask, C.B.

1983-09-01T23:59:59.000Z

222

Rigorous Development of Dependable Systems Using Fault Tolerance Views  

Science Conference Proceedings (OSTI)

This paper introduces the Mode and Fault Tolerance Views approach to stepwise rigorous development of critical systems. It supports systematic, structured and recursive modelling of system fault tolerance, including error detection, error recovery and ... Keywords: formal methods, Event-B, fault tolerance, modal systems, case study, AOCS

Ilya Lopatkin; Alexei Iliasov; Alexander Romanovsky

2011-11-01T23:59:59.000Z

223

Yet Another Fault Injection Technique : by Forward Body Biasing Injection  

E-Print Network (OSTI)

expensive fault injection tech- niques, like clock or voltage glitches, are well taken into accountYet Another Fault Injection Technique : by Forward Body Biasing Injection K. TOBICH1,2, P. MAURINE1 Injection, Electromag- netic Attacks, RSA, Chinese Remainder Theorem 1 Introduction Fault injection

224

Statistical estimation of multiple faults in aircraft gas turbine engines  

E-Print Network (OSTI)

415 Statistical estimation of multiple faults in aircraft gas turbine engines S Sarkar, C Rao of multiple faults in aircraft gas-turbine engines, based on a statistical pattern recognition tool called commercial aircraft engine. Keywords: aircraft propulsion, gas turbine engines, multiple fault estimation

Ray, Asok

225

Applications of fault detection methods to industrial processes  

Science Conference Proceedings (OSTI)

Components of industrial processes are often affected by un-permitted or un-expected deviations from normal operation behaviour. The fault detection task consists of determination of the fault present in a system and the time of detection. In addition ... Keywords: fault detection and diagnosis, industrial processes, residuals, symptoms

Ioana Fagarasan; S. S. T. Iliescu

2008-06-01T23:59:59.000Z

226

Collective operations in application-level fault-tolerant MPI  

Science Conference Proceedings (OSTI)

Fault-tolerance is becoming a critical issue on high-performance platforms. Checkpointing techniques make programs fault-tolerant by saving their state periodically and restoring this state after failure. System-level checkpointing saves the state ... Keywords: MPI, application-level checkpointing, collective communication, fault-tolerance, non-FIFO communication, scientific computing

Greg Bronevetsky; Daniel Marques; Keshav Pingali; Paul Stodghill

2003-06-01T23:59:59.000Z

227

Outlier Detection Rules for Fault Detection in Solar Photovoltaic Arrays  

E-Print Network (OSTI)

fault detection. Furthermore, the proposed models become more reliable as the number of PV measurements analysis specifically for PV installation. Several fault detection models and monitoring systems have been studied for PV systems [8]­[14]. PV monitoring and fault detection models based on energy yield and power

Lehman, Brad

228

A lightweight fault tolerance framework for Web services  

Science Conference Proceedings (OSTI)

In this paper, we present the design and implementation of a lightweight fault tolerance framework for Web services. With our framework, a Web service can be rendered fault tolerant by replicating it across several nodes. A consensus-based algorithm ... Keywords: Fault tolerance, Web services, distributed consensus, reliable messaging, replication

Wenbing Zhao; Honglei Zhang; Hua Chai

2009-08-01T23:59:59.000Z

229

Fault reconnaissance agent for sensor networks  

Science Conference Proceedings (OSTI)

One of the key prerequisite for a scalable, effective and efficient sensor network is the utilization of low-cost, low-overhead and high-resilient fault-inference techniques. To this end, we propose an intelligent agent system with a problem solving ... Keywords: Management, expectation maximization algorithm, intelligent agents, wireless sensor networks

Elhadi M. Shakshuki; Xinyu Xing; Tarek R. Sheltami

2010-08-01T23:59:59.000Z

230

Optimized Fault Location Final Project Report  

E-Print Network (OSTI)

excessive currents and voltages last long enough to cause equipment damage. CBs have the purpose to connect describes connectivity of the various components in the power system. In order to process retrieved fault, the system topology must be known. Beside the connectivity it is necessary to obtain information about

231

Zone refining of plutonium metal  

Science Conference Proceedings (OSTI)

The zone refining process was applied to Pu metal containing known amounts of impurities. Rod specimens of plutonium metal were melted into and contained in tantalum boats, each of which was passed horizontally through a three-turn, high-frequency coil in such a manner as to cause a narrow molten zone to pass through the Pu metal rod 10 times. The impurity elements Co, Cr, Fe, Ni, Np, U were found to move in the same direction as the molten zone as predicted by binary phase diagrams. The elements Al, Am, and Ga moved in the opposite direction of the molten zone as predicted by binary phase diagrams. As the impurity alloy was zone refined, {delta}-phase plutonium metal crystals were produced. The first few zone refining passes were more effective than each later pass because an oxide layer formed on the rod surface. There was no clear evidence of better impurity movement at the slower zone refining speed. Also, constant or variable coil power appeared to have no effect on impurity movement during a single run (10 passes). This experiment was the first step to developing a zone refining process for plutonium metal.

Blau, M.S.

1994-08-01T23:59:59.000Z

232

Anomalous zones in Gulf Coast Salt domes with special reference to Big Hill, TX, and Weeks Island, LA  

Science Conference Proceedings (OSTI)

Anomalous features in Gulf Coast Salt domes exhibit deviations from normally pure salt and vary widely in form from one dome to the next, ranging considerably in length and width. They have affected both conventional and solution mining in several ways. Gas outbursts, insolubles, and potash (especially carnallite) have led to the breakage of tubing in a number of caverns, and caused irregular shapes of many caverns through preferential leaching. Such anomalous features essentially have limited the lateral extent of conventional mining at several salt mines, and led to accidents and even the closing of several other mines. Such anomalous features, are often aligned in anomalous zones, and appear to be related to diapiric processes of salt dome development. Evidence indicates that anomalous zones are found between salt spines, where the differential salt intrusion accumulates other materials: Anhydrite bands which are relatively strong, and other, weaker impurities. Shear zones and fault displacement detected at Big Hill and Weeks Island domes have not yet had any known adverse impacts on SPR oil storage, but new caverns at these sites conceivably may encounter some potentially adverse conditions. Seismic reflection profiles at Big Hill dome have shown numerous fractures and faults in the caprock, and verified the earlier recognition of a major shear zone transecting the entire salt stock and forming a graben in the overlying caprock. Casing that is placed in such zones can be at risk. Knowledge of these zones should create awareness of possible effects rather than preclude the future emplacement of caverns. To the extent possible, major anomalous zones and salt stock boundaries should be avoided. Shear zones along overhangs may be particularly hazardous, and otherwise unknown valleys in the top of salt may occur along shear zones. These zones often can be mapped geophysically, especially with high-resolution seismic techniques.

Neal, J.T. [Sandia National Labs., Albuquerque, NM (United States); Magorian, T.R. [Magorian (Thomas R.), Amherst, NY (United States); Thoms, R.L. [AGM, Inc., College Station, TX (United States); Autin, W.J.; McCulloh, R.P. [Louisiana Geological Survey, Baton Rouge, LA (United States); Denzler, S.; Byrne, K.O. [Acres International Corp., Amherst, NY (United States)

1993-07-01T23:59:59.000Z

233

Coordinated Fault Tolerance for High-Performance Computing  

SciTech Connect

Our work to meet our goal of end-to-end fault tolerance has focused on two areas: (1) improving fault tolerance in various software currently available and widely used throughout the HEC domain and (2) using fault information exchange and coordination to achieve holistic, systemwide fault tolerance and understanding how to design and implement interfaces for integrating fault tolerance features for multiple layers of the software stackfrom the application, math libraries, and programming language runtime to other common system software such as jobs schedulers, resource managers, and monitoring tools.

Dongarra, Jack; Bosilca, George; et al.

2013-04-08T23:59:59.000Z

234

Active Fault Segments As Potential Earthquake Sources- Inferences From  

Open Energy Info (EERE)

Active Fault Segments As Potential Earthquake Sources- Inferences From Active Fault Segments As Potential Earthquake Sources- Inferences From Integrated Geophysical Mapping Of The Magadi Fault System, Southern Kenya Rift Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: Active Fault Segments As Potential Earthquake Sources- Inferences From Integrated Geophysical Mapping Of The Magadi Fault System, Southern Kenya Rift Details Activities (0) Areas (0) Regions (0) Abstract: Southern Kenya Rift has been known as a region of high geodynamic activity expressed by recent volcanism, geothermal activity and high rate of seismicity. The active faults that host these activities have not been investigated to determine their subsurface geometry, faulting intensity and constituents (fluids, sediments) for proper characterization of tectonic

235

Definition: Enhanced Fault Detection Technology | Open Energy Information  

Open Energy Info (EERE)

Technology Technology Jump to: navigation, search Dictionary.png Enhanced Fault Detection Technology Enhanced fault detection technology enables higher precision and greater discrimination of fault location and type with coordinated measurement among multiple devices. For distribution applications, this technology can detect and isolate faults without full-power re-closing, reducing the frequency of through-fault currents. Using high resolution sensors and fault signatures, this technology can better detect high impedance faults. For transmission applications, this technology will employ high speed communications between multiple elements (e.g., stations) to protect entire regions, rather than just single elements. It can also use the latest digital techniques to advance beyond conventional impedance relaying of

236

New method for abbreviating the fault tree graphical representation  

SciTech Connect

Fault tree analysis is being widely used for reliability and safety analysis of systems encountered in the nuclear industry and elsewhere. A disadvantage of the fault tree method is the voluminous fault tree graphical representation that conventionally results from analysis of a complex system. Previous methods for shortening the fault tree graphical representation include (1) transfers within the fault tree, and (2) the use of the SAMPLE (K out of N logic) gate, the MATRIX gate, and the SUMMATION gate. The purpose of this presentation is to introduce TABULATION gates as a method to abbreviate the fault tree graphical representation. These new gates reduce the cost of analysis and generally increase the system behavior visibility that is inherent in the fault tree technique. (auth)

Stewart, M.E.; Fussell, J.B.; Crump, R.J.

1974-12-01T23:59:59.000Z

237

Climate Zone 1B | Open Energy Information  

Open Energy Info (EERE)

search A type of climate defined in the ASHRAE 169-2006 standard consisting of Climate Zone Number 1 and Climate Zone Subtype B. Climate Zone 1B is defined as Dry with...

238

Climate Zone 8B | Open Energy Information  

Open Energy Info (EERE)

search A type of climate defined in the ASHRAE 169-2006 standard consisting of Climate Zone Number 8 and Climate Zone Subtype B. Climate Zone 8B is defined as Subarctic...

239

Climate Zones | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Residential Buildings » Building America » Climate Zones Residential Buildings » Building America » Climate Zones Climate Zones Building America determines building practices based on climate zones to achieve the most energy savings in a home. This page offers some general guidelines on the definitions of the various climate regions based on heating degree-days, average temperatures, and precipitation. You can also view the Guide to Determining Climate Regions by County. Hot-Humid A hot-humid climate is generally defined as a region that receives more than 20 in. (50 cm) of annual precipitation and where one or both of the following occur: A 67°F (19.5°C) or higher wet bulb temperature for 3,000 or more hours during the warmest 6 consecutive months of the year; or A 73°F (23°C) or higher wet bulb temperature for 1,500 or more

240

Undulator Hall Air Temperature Fault Scenarios  

SciTech Connect

Recent experience indicates that the LCLS undulator segments must not, at any time following tuning, be allowed to change temperature by more than about {+-}2.5 C or the magnetic center will irreversibly shift outside of acceptable tolerances. This vulnerability raises a concern that under fault conditions the ambient temperature in the Undulator Hall might go outside of the safe range and potentially could require removal and retuning of all the segments. In this note we estimate changes that can be expected in the Undulator Hall air temperature for three fault scenarios: (1) System-wide power failure; (2) Heating Ventilation and Air Conditioning (HVAC) system shutdown; and (3) HVAC system temperature regulation fault. We find that for either a system-wide power failure or an HVAC system shutdown (with the technical equipment left on), the short-term temperature changes of the air would be modest due to the ability of the walls and floor to act as a heat ballast. No action would be needed to protect the undulator system in the event of a system-wide power failure. Some action to adjust the heat balance, in the case of the HVAC power failure with the equipment left on, might be desirable but is not required. On the other hand, a temperature regulation failure of the HVAC system can quickly cause large excursions in air temperature and prompt action would be required to avoid damage to the undulator system.

Sevilla, J.

2010-11-17T23:59:59.000Z

Note: This page contains sample records for the topic "madrid fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Neural net application to transmission line fault detection and classification  

E-Print Network (OSTI)

Today, in electric power systems, a large amount of data is made readily available at the occurrence of a fault due to the use of advanced communication systems, digital relays and fault recorders. Such systems are intended to obtain data from contacts of the relays and circuit breakers under operation. In addition, corresponding voltages and currents are recorded during prefault, fault and postfault periods. Restoration of power Systems after a fault occurred requires quick judgment. Hence, fault analysis, as the first step of restoration is very important. However, since faults in power systems are various and relaying systems may be complex, fault analysis is difficult to automate. Common practice in power utility companies, today, is to perform fault analysis by expert operators using their knowledge about the power systems and experience with past faults. Because of the time required to deal with complex fault situations, detailed fault analysis can not be performed by human operators in a short time. Therefore, on-line automated fault analysis system is strongly desired. Traditional approaches to the problem of analysis is to construct a heuristic, rule-based system which embodies a portion of the compiled experience of a human expert. These systems perform fault analysis by mapping fault indications to fault hypotheses. 'These hypotheses are used as inputs for next level of rules. After completion of inferencing process, conclusions are given. The knowledge acquisition process is exhaustive and time consuming. Also, data processing is usually too slow to be effectively applied in a real-time environment. Neural computing is one of the rapidly expanding areas of current research. Neural nets have some obvious advantages over expert systems. They are computationally more effective because of their parallel processing capabilities. Also, there is no need for detailed knowledge acquisition part, because neural nets learn by example. This thesis presents results of a study on using the new neural net system that can perform both on-line and off-line fault detection and classification. Fault analysis is conceptualized as a pattern classification problem which involves the association of input patterns representing the power system state to one or more fault conditions.

Rikalo, Igor

1994-01-01T23:59:59.000Z

242

Alternative Energy Zone (Ohio) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Alternative Energy Zone (Ohio) Alternative Energy Zone (Ohio) < Back Eligibility Local Government StateProvincial Govt Savings Category Buying & Making Electricity Water Home...

243

Transition Zone Geothermal Region | Open Energy Information  

Open Energy Info (EERE)

Transition Zone Geothermal Region Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Transition Zone Geothermal Region edit Details Areas (5) Power Plants (0) Projects...

244

Calculating the probability of injected carbon dioxide plumes encountering faults  

Science Conference Proceedings (OSTI)

One of the main concerns of storage in saline aquifers is leakage via faults. In the early stages of site selection, site-specific fault coverages are often not available for these aquifers. This necessitates a method using available fault data to estimate the probability of injected carbon dioxide encountering and migrating up a fault. The probability of encounter can be calculated from areal fault density statistics from available data, and carbon dioxide plume dimensions from numerical simulation. Given a number of assumptions, the dimension of the plume perpendicular to a fault times the areal density of faults with offsets greater than some threshold of interest provides probability of the plume encountering such a fault. Application of this result to a previously planned large-scale pilot injection in the southern portion of the San Joaquin Basin yielded a 3% and 7% chance of the plume encountering a fully and half seal offsetting fault, respectively. Subsequently available data indicated a half seal-offsetting fault at a distance from the injection well that implied a 20% probability of encounter for a plume sufficiently large to reach it.

Jordan, P.D.

2011-04-01T23:59:59.000Z

245

Application of Support Vector Machine (SVM) and Proximal Support Vector Machine (PSVM) for fault classification of monoblock centrifugal pump  

Science Conference Proceedings (OSTI)

Monoblock centrifugal pumps are widely used in a variety of applications. Defects and malfunctions (faults) of these pumps result in significant economic loss. Therefore, the pumps must be under constant monitoring. When a possible fault is detected, ... Keywords: CAV, PSVM, bearing faults, cavitation, decision trees, fault classification, fault diagnosis, impeller faults, monoblock centrifugal pumps, proximal SVM, seal faults, support vector machines, vibration signals

N. R. Sakthivel; V. Sugumaran; Binoy B. Nair

2010-12-01T23:59:59.000Z

246

Table C10A. Consumption and Gross Energy Intensity by Climate Zone ...  

U.S. Energy Information Administration (EIA)

Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 All Buildings ..... 1,086 1,929 1,243 1,386 879 11,529 ...

247

Towards a bayesian seismotectonic zoning for use in Probabilistic Seismic Hazard Assessment (PSHA)  

SciTech Connect

The mathematical representation of seismic sources is an important part of probabilistic seismic hazard assessment. It reflects the association of the seismicity with the tectonically-active geological structures evidenced by seismotectonic studies. Given that most active faults are not characterized well enough, seismic sources are generally defined as areal zones, delimited with finite boundary polygons, within which the geological features of active tectonics and the seismicity are deemed homogeneous (e.g., focal depth, seismicity rate, and maximum magnitude). Besides the lack of data (e.g., narrow range of recorded magnitudes), the application of this representation generates different problems: 1) a large sensitivity of resulting hazard maps on the location of zone boundaries, while these boundaries are set by expert decision; 2) the zoning can not represent any variation in faulting mechanism; 3) the seismicity rates are distributed throughout the zones and we lose the location of the determinant information used for their calculation. We propose an exploratory study for an alternative procedure in area source modeling. First, different data (e.g., geomorphology, geology, fault orientations) will be combined by using automated spatial partitioning (investigation of both supervised and unsupervised methods) in order to obtain several information classes, which may be defined as areal source zones. Then, a given hypocenter belonging to a given ''zone'', from now on called seismicity model, will be expressed by a probability computed from the 2D (spatial) probability density function (pdf) for the active tectonic model used as an a priori and updated with specific data from seismicity catalogs (e.g., focal mechanism) or other new data sources (e.g., geomorphology, subsurface exploration). This hypocenter will thus be allowed to contribute to several models, with weights given by the value of the pdf for each model. The annual rate of occurrence, for a given model, will be calculated by the weighted average of the different hypocenter contributions contained in this model. Future applications will couple the seismicity models to Ground Motion Prediction Equations. In consequence, the results will provide the full spectrum of variability in the hazard and will highlight zones badly constrained and deserving to be more studied.

Le Goff, Boris; Fitzenz, Delphine [CGE, University of Evora (Portugal); Beauval, Celine [LGIT-IRD (France)

2011-03-14T23:59:59.000Z

248

Type E: Extensional Tectonic, Fault-Controlled Resource | Open Energy  

Open Energy Info (EERE)

Type E: Extensional Tectonic, Fault-Controlled Resource Type E: Extensional Tectonic, Fault-Controlled Resource Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Type E: Extensional Tectonic, Fault-Controlled Resource Dictionary.png Type E: Extensional Tectonic, Fault-Controlled Resource: No definition has been provided for this term. Add a Definition Brophy Occurrence Models This classification scheme was developed by Brophy, as reported in Updating the Classification of Geothermal Resources.[1] Type A: Magma-heated, Dry Steam Resource Type B: Andesitic Volcanic Resource Type C: Caldera Resource Type D: Sedimentary-hosted, Volcanic-related Resource Type E: Extensional Tectonic, Fault-Controlled Resource Type F: Oceanic-ridge, Basaltic Resource Extensional-tectonic, fault-controlled resources typically result from a

249

Scalable distributed consensus to support MPI fault tolerance.  

Science Conference Proceedings (OSTI)

As system sizes increase, the amount of time in which an application can run without experiencing a failure decreases. Exascale applications will need to address fault tolerance. In order to support algorithm-based fault tolerance, communication libraries will need to provide fault-tolerance features to the application. One important fault-tolerance operation is distributed consensus. This is used, for example, to collectively decide on a set of failed processes. This paper describes a scalable, distributed consensus algorithm that is used to support new MPI fault-tolerance features proposed by the MPI 3 Forum's fault-tolerance working group. The algorithm was implemented and evaluated on a 4,096-core Blue Gene/P. The implementation was able to perform a full-scale distributed consensus in 305 {mu}s and scaled logarithmically.

Buntinas, D. (Mathematics and Computer Science)

2011-01-01T23:59:59.000Z

250

Similarity Matching Techniques for Fault Diagnosis in Automotive Infotainment Electronics  

E-Print Network (OSTI)

Fault diagnosis has become a very important area of research during the last decade due to the advancement of mechanical and electrical systems in industries. The automobile is a crucial field where fault diagnosis is given a special attention. Due to the increasing complexity and newly added features in vehicles, a comprehensive study has to be performed in order to achieve an appropriate diagnosis model. A diagnosis system is capable of identifying the faults of a system by investigating the observable effects (or symptoms). The system categorizes the fault into a diagnosis class and identifies a probable cause based on the supplied fault symptoms. Fault categorization and identification are done using similarity matching techniques. The development of diagnosis classes is done by making use of previous experience, knowledge or information within an application area. The necessary information used may come from several sources of knowledge, such as from system analysis. In this paper similarity matching tec...

Kabir, Mashud

2009-01-01T23:59:59.000Z

251

Enhancing and Testing Fast Fault Screening (FFS) Methodology  

Science Conference Proceedings (OSTI)

The aim of this multi-year study is to develop a methodology for fast prediction of the most severe three-phase fault locations for transient stability studies and rank them in order of severity. The methodology is called Fast Fault Screening (FFS). The key advantage of the FFS is the ability to quickly scan through thousands of potential fault locations from transient stability perspective and identify the most severe locations. In the previous efforts, FFS was developed for angular ...

2012-12-31T23:59:59.000Z

252

Impact of Wind Power Integration on Fault Current Management  

Science Conference Proceedings (OSTI)

This report presents a study on the impact of wind power integration on the grid fault current level due to various types of faults that might take place inside or outside of wind farms. Wind power is one of the renewable energy sources that has shown tremendous growth in recent years. The increasing integration of wind energy generation and other distributed renewable energy generation could change grid behavior under fault situations and influence system stability. Specifically, integration of addition...

2010-01-14T23:59:59.000Z

253

Timer-based composition of fault-containing self-stabilizing protocols  

Science Conference Proceedings (OSTI)

One of the desired properties of distributed systems is self-adaptability against faults. Self-stabilizing protocols provide autonomous recovery from any finite number of transient faults. However, in practice, catastrophic faults rarely occur, while ... Keywords: Distributed system, Fault tolerance, Fault-containment, Hierarchical composition, Self-adaptability, Self-stabilization, Synchronizer, Timer

Yukiko Yamauchi; Sayaka Kamei; Fukuhito Ooshita; Yoshiaki Katayama; Hirotsugu Kakugawa; Toshimitsu Masuzawa

2010-05-01T23:59:59.000Z

254

Category:ASHRAE Climate Zones | Open Energy Information  

Open Energy Info (EERE)

ASHRAE Climate Zones ASHRAE Climate Zones Jump to: navigation, search Climate Zones defined in the ASHRAE 169-2006 standards. Pages in category "ASHRAE Climate Zones" The following 30 pages are in this category, out of 30 total. C Climate Zone 1A Climate Zone 1B Climate Zone 2A Climate Zone 2B Climate Zone 3A Climate Zone 3B Climate Zone 3C Climate Zone 4A Climate Zone 4B Climate Zone 4C C cont. Climate Zone 5A Climate Zone 5B Climate Zone 5C Climate Zone 6A Climate Zone 6B Climate Zone 7A Climate Zone 7B Climate Zone 8A Climate Zone 8B Climate Zone Number 1 C cont. Climate Zone Number 2 Climate Zone Number 3 Climate Zone Number 4 Climate Zone Number 5 Climate Zone Number 6 Climate Zone Number 7 Climate Zone Number 8 Climate Zone Subtype A Climate Zone Subtype B Climate Zone Subtype C Retrieved from

255

Historic Surface Faulting and Paleoseismicity in the Area of...  

Open Energy Info (EERE)

Historic Surface Faulting and Paleoseismicity in the Area of the 1954 Rainbow Mountain-Stillwater Earthquake Sequence, Central Nevada Jump to: navigation, search OpenEI Reference...

256

Low-cost motor drive embedded fault diagnosis systems  

E-Print Network (OSTI)

Electric motors are used widely in industrial manufacturing plants. Bearing faults, insulation faults, and rotor faults are the major causes of electric motor failures. Based on the line current analysis, this dissertation mainly deals with the low cost incipient fault detection of inverter-fed driven motors. Basically, low order inverter harmonics contributions to fault diagnosis, a motor drive embedded condition monitoring method, analysis of motor fault signatures in noisy line current, and a few specific applications of proposed methods are studied in detail. First, the effects of inverter harmonics on motor current fault signatures are analyzed in detail. The introduced fault signatures due to harmonics provide additional information about the motor faults and enhance the reliability of fault decisions. It is theoretically and experimentally shown that the extended fault signatures caused by the inverter harmonics are similar and comparable to those generated by the fundamental harmonic on the line current. In the next chapter, the reference frame theory is proposed as a powerful toolbox to find the exact magnitude and phase quantities of specific fault signatures in real time. The faulty motors are experimentally tested both offline, using data acquisition system, and online, employing the TMS320F2812 DSP to prove the effectiveness of the proposed tool. In addition to reference frame theory, another digital signal processor (DSP)-based phasesensitive motor fault signature detection is presented in the following chapter. This method has a powerful line current noise suppression capability while detecting the fault signatures. It is experimentally shown that the proposed method can determine the normalized magnitude and phase information of the fault signatures even in the presence of significant noise. Finally, a signal processing based fault diagnosis scheme for on-board diagnosis of rotor asymmetry at start-up and idle mode is presented. It is quite challenging to obtain these regular test conditions for long enough time during daily vehicle operations. In addition, automobile vibrations cause a non-uniform air-gap motor operation which directly affects the inductances of electric motor and results quite noisy current spectrum. The proposed method overcomes the challenges like aforementioned ones simply by testing the rotor asymmetry at zero speed.

Akin, Bilal

2007-08-01T23:59:59.000Z

257

Upper crustal faulting in an obliquely extending orogen, structural...  

Open Energy Info (EERE)

faulting in an obliquely extending orogen, structural control on permeability and production in the Coso Geothermal Field, eastern California Jump to: navigation, search...

258

Dynamic analysis and fault diagnosis of a water hydraulic motor.  

E-Print Network (OSTI)

??This research is concerned with condition monitoring and fault diagnosis of the piston of the water hydraulic motor by vibration signal analysis. Vibration signatures are (more)

Chen, Hanxin.

2008-01-01T23:59:59.000Z

259

MICRO-SEISMICITY, FAULT STRUCTURE AND HYDRAULIC COMPARTMENTALIZATION...  

Open Energy Info (EERE)

MICRO-SEISMICITY, FAULT STRUCTURE AND HYDRAULIC COMPARTMENTALIZATION WITHIN THE COSO GETHERMAL FIELD, CALIFORNIA Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home...

260

Fault Detection and Diagnosis in Building HVAC Systems  

E-Print Network (OSTI)

diagnostic method for vapor compression air conditioners,evaluation of faults in vapor compression cycle equipment,Diagnostic Methods to Vapor Compression Cooling Equipment,

Najafi, Massieh

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "madrid fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Intersecting Fault Trends and Crustal-Scale Fluid Pathways Below...  

Open Energy Info (EERE)

Intersecting Fault Trends and Crustal-Scale Fluid Pathways Below the Dixie Valley Geothermal Area, Nevada, Inferred from 3d Magnetotelluric Surveying Jump to: navigation, search...

262

CiFTS : Coordinated Infrastructure for Fault Tolerant Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

Demos Team News Contact Us Coordinated and Improved Fault Tolerance for High Performance Computing Systems In the next few years SciDAC applications will utilize exascale...

263

Petri net modeling of fault analysis for probabilistic risk assessment.  

E-Print Network (OSTI)

??Fault trees and event trees have been widely accepted as the modeling strategy to perform Probabilistic Risk Assessment (PRA). However, there are several limitations associated (more)

Lee, Andrew

2013-01-01T23:59:59.000Z

264

Cryptic Faulting and Multi-Scale Geothermal Fluid Connections...  

Open Energy Info (EERE)

Cryptic Faulting and Multi-Scale Geothermal Fluid Connections in the Dixie Valley-Central Nevada Seismic Belt Area- Implications from Mt Resistivity Surveying Jump to: navigation,...

265

Recency Of Faulting And Neotechtonic Framework In The Dixie Valley...  

Open Energy Info (EERE)

Recency Of Faulting And Neotechtonic Framework In The Dixie Valley Geothermal Field And Other Geothermal Fields Of The Basin And Range Jump to: navigation, search GEOTHERMAL...

266

An Assessment of Fault Current Limiter Testing Requirements ...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Reliability (OE) is conducting research and development (R&D) on next-generation electricity delivery equipment including fault current limiters (FCLs). Prototype FCL...

267

Recurrent faulting and petroleum accumulation, Cat Creek Anticline, central Montana  

SciTech Connect

The Cat Creek anticline, scene of central Montana's first significant oil discovery, is underlain by a south-dipping high-angle fault (Cat Creek fault) that has undergone several episodes of movement with opposite sense of displacement. Borehole data suggest that the Cat Creek fault originated as a normal fault during Proterozoic rifting concurrent with deposition of the Belt Supergroup. Reverse faulting took place in Late Cambrian time, and again near the end of the Devonian Period. The Devonian episode, coeval with the Antler orogeny, raised the southern block several hundred feet. The southern block remained high through Meramecian time, then began to subside. Post-Atokan, pre-Middle Jurassic normal faulting lowered the southern block as much as 1,500 ft. During the Laramide orogeny (latest Cretaceous-Eocene) the Cat Creek fault underwent as much as 4,000 ft of reverse displacement and a comparable amount of left-lateral displacement. The Cat Creek anticline is a fault-propagation fold; en echelon domes and listric normal faults developed along its crest in response to wrenching. Oil was generated mainly in organic-rich shales of the Heath Formation (upper Chesterian Series) and migrated upward along tectonic fractures into Pennsylvanian, Jurassic, and Cretaceous reservoir rocks in structural traps in en echelon domes. Production has been achieved only from those domes where structural closure was retained from Jurassic through Holocene time.

Nelson, W.J. (Illinois State Geological Survey, Champaign (United States))

1991-06-01T23:59:59.000Z

268

Recent earthquake sequences at Coso: Evidence for conjugate faulting...  

Open Energy Info (EERE)

Recent earthquake sequences at Coso: Evidence for conjugate faulting and stress loading near a geothermal field Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal...

269

Fault Prediction and Fault-Tolerant of Lithium-ion Batteries Temperature Failure for Electric Vehicle  

Science Conference Proceedings (OSTI)

Design and implementation of dual-redundancy was developed to predict Lithium-ion battery failure for electric vehicle. Data fusion unit, prediction unit and determination unit were designed. Outputs from original and redundant sensors were integrated ... Keywords: Lithium-ion battery, dual-redundancy, data fusion, prediction, Fault-tolerant

Hu Chunhua; He Ren; Wang Runcai; Yu Jianbo

2012-07-01T23:59:59.000Z

270

A fuzzy neural network based fault detection scheme for synchronous generator with internal fault  

Science Conference Proceedings (OSTI)

A fuzzy neural network (FNN) based inter-turn short circuit fault detection scheme for generator is proposed. The second harmonic magnitude of field current and the negative sequence components of voltages and currents are used as inputs for the FNN ...

Hongwei Fang; Changliang Xia

2009-08-01T23:59:59.000Z

271

Prototyping a fault-tolerant multiprocessor SoC with run-time fault recovery  

Science Conference Proceedings (OSTI)

Modern integrated circuits (ICs) are becoming increasingly complex. The complexity makes it difficult to design, manufacture and integrate these high performance ICs. The advent of multiprocessor Systems-on-chips (SoCs) makes it even more challenging ... Keywords: fault-tolerance, multiprocessor system, network-on-chip, retargetable simulation, run-time verification, system-on-chip

Xinping Zhu; Wei Qin

2006-07-01T23:59:59.000Z

272

Reinvestigation of fault trace complexity and slip distribution for the 16 December 1954 Fairview Peak (Ms = 7. 2) and Dixie Valley (Ms = 6. 8) earthquakes, Central Nevada  

Science Conference Proceedings (OSTI)

With the use of 1:12K scale low-sun angle photography, the authors have traversed and mapped details of the surface trace and slip distribution of the 1954 Fairview Peak (FVP) earthquake ruptures. The FVP earthquake produced a complex pattern of surface faulting along a 50 km long, 6 km wide, north striking zone and was followed 4 minutes later by the Dixie Valley event. Surface ruptures of the Dixie Valley event extend northward for 45 km along the west side of Dixie Valley and are separated from the FVP ruptures by a 6 km step in the mapped trace of the surface ruptures. Prior measurements of fault offsets (Slemmons, 1957) are few and available maps are relatively small scale. The initial purpose of the effort is therefore to document the sense, amount, and distribution of surface offsets along both fault systems. The results will form the basis to construct a 3-dimensional model of the fault system and to examine the static stress field changes along the Dixie Valley fault induced by the preceding FVP earthquake.

Caskey, S.J.; Wesnousky, S.G. (Univ. of Nevada, Reno, NV (United States). Center for Neotectonic Studies); Zhang, P. (State Seismological Bureau, Beijing (China). Inst. of Geology); Slemmons, D.B.

1993-04-01T23:59:59.000Z

273

Automating Power System Fault Diagnosis through Multi-Agent System Technology  

Science Conference Proceedings (OSTI)

Fault diagnosis within electrical power systems is a time consuming and complex task. SCADA systems, digital fault recorders, travelling wave fault locators and other monitoring devices are drawn upon to inform the engineers of incidents, problems and ...

S. D. J. McArthur; E. M. Davidson; J. A. Hossack; J. R. McDonald

2004-01-01T23:59:59.000Z

274

Feng shui of supercomputer memory: positional effects in DRAM and SRAM faults  

Science Conference Proceedings (OSTI)

Several recent publications confirm that faults are common in high-performance computing systems. Therefore, further attention to the faults experienced by such computing systems is warranted. In this paper, we present a study of DRAM and SRAM faults ...

Vilas Sridharan, Jon Stearley, Nathan DeBardeleben, Sean Blanchard, Sudhanva Gurumurthi

2013-11-01T23:59:59.000Z

275

Zone refining of plutonium metal  

Science Conference Proceedings (OSTI)

The purpose of this study was to investigate zone refining techniques for the purification of plutonium metal. The redistribution of 10 impurity elements from zone melting was examined. Four tantalum boats were loaded with plutonium impurity alloy, placed in a vacuum furnace, heated to 700{degrees}C, and held at temperature for one hour. Ten passes were made with each boat. Metallographic and chemical analyses performed on the plutonium rods showed that, after 10 passes, moderate movement of certain elements were achieved. Molten zone speeds of 1 or 2 inches per hour had no effect on impurity element movement. Likewise, the application of constant or variable power had no effect on impurity movement. The study implies that development of a zone refining process to purify plutonium is feasible. Development of a process will be hampered by two factors: (1) the effect on impurity element redistribution of the oxide layer formed on the exposed surface of the material is not understood, and (2) the tantalum container material is not inert in the presence of plutonium. Cold boat studies are planned, with higher temperature and vacuum levels, to determine the effect on these factors. 5 refs., 1 tab., 5 figs.

NONE

1997-05-01T23:59:59.000Z

276

First step towards automatic correction of firewall policy faults  

Science Conference Proceedings (OSTI)

Firewalls are critical components of network security and have been widely deployed for protecting private networks. A firewall determines whether to accept or discard a packet that passes through it based on its policy. However, most real-life firewalls ... Keywords: Automatic fault fixing, firewall faults, firewall policy

Fei Chen; Alex X. Liu; Jeehyun Hwang; Tao Xie

2012-07-01T23:59:59.000Z

277

Fault Diagnosis of Transformer Based on Random Forest  

Science Conference Proceedings (OSTI)

Fault diagnosis of transformer in power system is studied in this paper. Considering the excellent performances of Random Forest (RF) in pattern recognition, we apply RF to construct a diagnosis model to predict the situation of transformer. The experiments ... Keywords: Rondom Forest, fault diagnosis of transformer, classification model

Xi Chen; Hongmei Cui; Linkai Luo

2011-03-01T23:59:59.000Z

278

ANFIS based sensor fault detection for continuous stirred tank reactor  

Science Conference Proceedings (OSTI)

In this paper, an Adaptive Neuro-Fuzzy Inference System (ANFIS) based Sensor fault detection and isolation for Continuous Stirred Tank Reactor (CSTR) is proposed. CSTR is a highly nonlinear process exhibiting stable and unstable steady state at different ... Keywords: ANFIS observer, Continuous stirred tank reactor, Dedicated observer, Fault detection

U. Sabura Banu; G. Uma

2011-03-01T23:59:59.000Z

279

Increasing fault-tolerance in cellular automata-based systems  

Science Conference Proceedings (OSTI)

In the light of emergence of cellular computing, new cellular computing systems based on yet-unknown methods of fabrication need to address the problem of fault tolerance in a way which is not tightly connected to used technology. This may not be possible ... Keywords: Byl's loop, Game of Life, TMR, cellular automata, cellular computing, fault tolerance, rule 30, static module redundance

Lud?k aloudek; Luk Sekanina

2011-06-01T23:59:59.000Z

280

Symbolic identification for fault detection in aircraft gas turbine engines  

E-Print Network (OSTI)

Symbolic identification for fault detection in aircraft gas turbine engines S Chakraborty, S Sarkar and computationally inexpensive technique of component-level fault detection in aircraft gas-turbine engines identification, gas turbine engines, language-theoretic analysis 1 INTRODUCTION The propulsion system of modern

Ray, Asok

Note: This page contains sample records for the topic "madrid fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

CUDA accelerated fault tree analysis with C-XSC  

Science Conference Proceedings (OSTI)

Fault tree analysis is a widespread mathematical method for determining the failure probability of observed real-life systems. In addition to failure probability defined by wear, the system model has to take into account intrinsic and extrinsic system ... Keywords: C-XSC, CUDA, DSI, fault tree analysis

Gabor Rebner; Michael Beer

2012-09-01T23:59:59.000Z

282

GPS satellite oscillator faults mimicking ionospheric phase scintillation  

Science Conference Proceedings (OSTI)

It is possible for unreported Global Positioning System satellite faults to cause phase variations mimicking the effect of ionospheric scintillation. A case study of an event on 17 May, 2011 is presented. For approximately 695 s, the L1 signal from the ... Keywords: Anomaly, Fault, Navstar 43, PRN 13, Scintillation, Sigma-phi

Christopher J. Benton; Cathryn N. Mitchell

2012-10-01T23:59:59.000Z

283

Towards Robustness in Neural Network Based Fault Diagnosis  

Science Conference Proceedings (OSTI)

Challenging design problems arise regularly in modern fault diagnosis systems. Unfortunately, classical analytical techniques often cannot provide acceptable solutions to such difficult tasks. This explains why soft computing techniques such as neural ... Keywords: Dynamic Neural Network, Fault Diagnosis, Gmdh Neural Network, Robustness

Krzysztof Patan; Marcin Witczak; JZef Korbicz

2008-12-01T23:59:59.000Z

284

Fault detection in multivariate signals with applications to gas turbines  

Science Conference Proceedings (OSTI)

This paper proposes a fault detection method for multivariate signals. The method assesses whether or not the multivariate autocovariance functions of two independently sampled system signals coincide. If the first signal is known to be sampled from ... Keywords: autocovariances, fault detection, spectral analysis, stationary time series

Hany Bassily; Robert Lund; John Wagner

2009-03-01T23:59:59.000Z

285

COMPLETE FAULT ANALYSIS FOR LONG TRANSMISSION LINE USING  

E-Print Network (OSTI)

Plants and Power Systems Control, Kananaskis, Canada, 2006 #12;Area Measurement System (WAMS) and Phasor variables. Methods based on traveling waves and recently based on fault- generated high-frequency transients of the fault location. This method will be more attractive when the concept of Wide IFAC Symposium on Power

286

Online Fault Detection and Tolerance for Photovoltaic Energy Harvesting Systems  

E-Print Network (OSTI)

Online Fault Detection and Tolerance for Photovoltaic Energy Harvesting Systems Xue Lin 1 , Yanzhi, yanzhiwa, dizhu, pedram}@usc.edu, 2 naehyuck@elpl.snu.ac.kr ABSTRACT Photovoltaic energy harvesting systems (PV systems) are subject to PV cell faults, which decrease the efficiency of PV systems and even

Pedram, Massoud

287

Soft computing approach to fault diagnosis of centrifugal pump  

Science Conference Proceedings (OSTI)

Fault detection and isolation in rotating machinery is very important from an industrial viewpoint as it can help in maintenance activities and significantly reduce the down-time of the machine, resulting in major cost savings. Traditional methods have ... Keywords: Centrifugal pump, Decision tree algorithm, Fault diagnosis, Gene expression programming, Proximal support vector machine, Statistical features, Support vector machine

N. R. Sakthivel; Binoy.B.Nair; V. Sugumaran

2012-05-01T23:59:59.000Z

288

Effects of unbalanced faults on transient stability of cogeneration system  

Science Conference Proceedings (OSTI)

This paper evaluates the effects of unbalanced faults on the transient stability of a real cogeneration plant. First, a brief is given for the structure of the cogeneration system. Use of the electromagnetic transient program (EMTP) constructs the cogeneration ... Keywords: CCT curve, EMTP, cogeneration plant, transient stability, unbalanced faults

Wei-Neng Chang; Chia-Han Hsu

2011-10-01T23:59:59.000Z

289

Automatic Fault Characterization via Abnormality-Enhanced Classification  

Science Conference Proceedings (OSTI)

Enterprise and high-performance computing systems are growing extremely large and complex, employing hundreds to hundreds of thousands of processors and software/hardware stacks built by many people across many organizations. As the growing scale of these machines increases the frequency of faults, system complexity makes these faults difficult to detect and to diagnose. Current system management techniques, which focus primarily on efficient data access and query mechanisms, require system administrators to examine the behavior of various system services manually. Growing system complexity is making this manual process unmanageable: administrators require more effective management tools that can detect faults and help to identify their root causes. System administrators need timely notification when a fault is manifested that includes the type of fault, the time period in which it occurred and the processor on which it originated. Statistical modeling approaches can accurately characterize system behavior. However, the complex effects of system faults make these tools difficult to apply effectively. This paper investigates the application of classification and clustering algorithms to fault detection and characterization. We show experimentally that naively applying these methods achieves poor accuracy. Further, we design novel techniques that combine classification algorithms with information on the abnormality of application behavior to improve detection and characterization accuracy. Our experiments demonstrate that these techniques can detect and characterize faults with 65% accuracy, compared to just 5% accuracy for naive approaches.

Bronevetsky, G; Laguna, I; de Supinski, B R

2010-12-20T23:59:59.000Z

290

Research on Fault Location of Power Cable with Wavelet Analysis  

Science Conference Proceedings (OSTI)

This article researChes for 10kV transmission cable form the ground substation to the underground central substation in the coal mine. The transient traveLing wave signal of the cable fault is disposed by the wavelet transformation based on the cable ... Keywords: Wavelet analysis, Fault Location, TraveLing wave

Ji-meng Zhang; Shuo Liang

2011-08-01T23:59:59.000Z

291

Overlap zoned electrically heated particulate filter  

DOE Patents (OSTI)

A system includes a particulate matter (PM) filter that includes an upstream end for receiving exhaust gas and a downstream end. A zoned heater is arranged spaced from the upstream end and comprises N zones, where N is an integer greater than one, wherein each of the N zones comprises M sub-zones, where M is an integer greater than or equal to one, and wherein the N zones and the M sub-zones are arranged in P layers, where P is an integer greater than one. A control module selectively activates at least a selected one of the N zones to initiate regeneration in downstream portions of the PM filter from the one of the N zones and deactivates non-selected ones of the N zones.

Gonze, Eugene V [Pinckney, MI; Chapman, Mark R [Brighton, MI

2011-07-19T23:59:59.000Z

292

Dating of major normal fault systems using thermochronology- An example  

Open Energy Info (EERE)

Dating of major normal fault systems using thermochronology- An example Dating of major normal fault systems using thermochronology- An example from the Raft River detachment, Basin and Range, western United States Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: Dating of major normal fault systems using thermochronology- An example from the Raft River detachment, Basin and Range, western United States Details Activities (1) Areas (1) Regions (0) Abstract: Application of thermochronological techniques to major normal fault systems can resolve the timing of initiation and duration of extension, rates of motion on detachment faults, timing of ductile mylonite formation and passage of rocks through the crystal-plastic to brittle transition, and multiple events of extensional unroofing. Here we determine

293

Recent earthquake sequences at Coso: Evidence for conjugate faulting and  

Open Energy Info (EERE)

earthquake sequences at Coso: Evidence for conjugate faulting and earthquake sequences at Coso: Evidence for conjugate faulting and stress loading near a geothermal field Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: Recent earthquake sequences at Coso: Evidence for conjugate faulting and stress loading near a geothermal field Details Activities (1) Areas (1) Regions (0) Abstract: Two recent earthquake sequences near the Coso geothermal field show clear evidence of faulting along conjugate planes. We present results from analyzing an earthquake sequence occurring in 1998 and compare it with a similar sequence that occurred in 1996. The two sequences followed mainshocks that occurred on 27 November 1996 and 6 March 1998. Both mainshocks ruptured approximately colocated regions of the same fault

294

Definition: Apex or Salient of Normal Fault | Open Energy Information  

Open Energy Info (EERE)

Definition Definition Edit with form History Facebook icon Twitter icon » Definition: Apex or Salient of Normal Fault Jump to: navigation, search Dictionary.png Apex or Salient of Normal Fault Normal faults may intersect in the subsurface to form a fault apex or salient. Apices or salients of normal faults account for 3% of structural controls in the Great Basin.[2] View on Wikipedia Wikipedia Definition References ↑ James E. Faulds,Nicholas H. Hinz,Mark F. Coolbaugh,Patricia H. Cashman,Christopher Kratt,Gregory Dering,Joel Edwards,Brett Mayhew,Holly McLachlan. 2011. Assessment of Favorable Structural Settings of Geothermal Systems in the Great Basin, Western USA. In: Transactions. GRC Anual Meeting; 2011/10/23; San Diego, CA. Davis, CA: Geothermal Resources Council; p. 777-783

295

Probability Estimation of CO2 Leakage Through Faults at Geologic Carbon Sequestration Sites  

E-Print Network (OSTI)

for Geologic Carbon Sequestration Based on EffectiveFaults at Geologic Carbon Sequestration Sites Yingqi Zhang*,faults at geologic carbon sequestration (GCS) sites is a

Zhang, Yingqi

2009-01-01T23:59:59.000Z

296

Fault Analysis at a Wind Power Plant for One Year of Observation: Preprint  

DOE Green Energy (OSTI)

This paper analyzes the fault characteristics observed at a wind power plant, and the behavior of the wind power plant under fault events.

Muljadi, E.; Mills, Z.; Foster, R.; Conto, J.; Ellis, A.

2008-07-01T23:59:59.000Z

297

Unsaturated Zone and Saturated Zone Transport Properties (U0100)  

Science Conference Proceedings (OSTI)

This Analysis/Model Report (AMR) summarizes transport properties for the lower unsaturated zone hydrogeologic units and the saturated zone at Yucca Mountain and provides a summary of data from the Busted Butte Unsaturated Zone Transport Test (UZTT). The purpose of this report is to summarize the sorption and transport knowledge relevant to flow and transport in the units below Yucca Mountain and to provide backup documentation for the sorption parameters decided upon for each rock type. Because of the complexity of processes such as sorption, and because of the lack of direct data for many conditions that may be relevant for Yucca Mountain, data from systems outside of Yucca Mountain are also included. The data reported in this AMR will be used in Total System Performance Assessment (TSPA) calculations and as general scientific support for various Process Model Reports (PMRs) requiring knowledge of the transport properties of different materials. This report provides, but is not limited to, sorption coefficients and other relevant thermodynamic and transport properties for the radioisotopes of concern, especially neptunium (Np), plutonium (Pu), Uranium (U), technetium (Tc), iodine (I), and selenium (Se). The unsaturated-zone (UZ) transport properties in the vitric Calico Hills (CHv) are discussed, as are colloidal transport data based on the Busted Butte UZTT, the saturated tuff, and alluvium. These values were determined through expert elicitation, direct measurements, and data analysis. The transport parameters include information on interactions of the fractures and matrix. In addition, core matrix permeability data from the Busted Butte UZTT are summarized by both percent alteration and dispersion.

J. Conca

2000-12-20T23:59:59.000Z

298

Enterprise Zone Program (Louisiana) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Enterprise Zone Program (Louisiana) Enterprise Zone Program (Louisiana) Enterprise Zone Program (Louisiana) < Back Eligibility Commercial Construction Developer Fuel Distributor Industrial Installer/Contractor Institutional Investor-Owned Utility Nonprofit Retail Supplier Systems Integrator Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Louisiana Program Type Corporate Tax Incentive Enterprise Zone Provider Louisiana Economic Development The Enterprise Zone Program is a jobs incentive program providing Louisiana income and franchise tax credits to businesses hiring at least 35% of net, new jobs from targeted groups. Enterprise Zones (EZs) are areas with high unemployment, low income, or a high percentage of residents receiving some

299

Enterprise Zone Program (Alabama) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Alabama) Alabama) Enterprise Zone Program (Alabama) < Back Eligibility Commercial Construction Industrial Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Alabama Program Type Enterprise Zone Provider Alabama Department of Economic and Community Affairs The Enterprise Zone Program provides certain tax incentives to corporations, partnerships and proprietorships that locate or expand within designated Enterprise Zones. In addition to state-level tax incentives, businesses may also receive local tax and non-tax incentives for locating or expanding within a designated Enterprise Zone. Section 5 of the Alabama Enterprise Zone Program offers the following tax incentives: Credit based

300

Renewable Energy Renaissance Zones | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Renewable Energy Renaissance Zones Renewable Energy Renaissance Zones Renewable Energy Renaissance Zones < Back Eligibility Commercial Industrial Local Government Savings Category Bioenergy Solar Buying & Making Electricity Alternative Fuel Vehicles Heating & Cooling Swimming Pool Heaters Water Heating Commercial Heating & Cooling Heating Wind Maximum Rebate None Program Info Start Date 07/12/2006 State Michigan Program Type Industry Recruitment/Support Rebate Amount 100% abatement of Michigan Business Tax, state education tax, personal and real property taxes, and local income taxes Provider Michigan Economic Development Corporation In 2006, Michigan enacted legislation allowing for the creation of Renewable Energy Renaissance Zones (RERZ). Renaissance zones -- renewable energy renaissance zones are just one type -- offer significant tax

Note: This page contains sample records for the topic "madrid fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Stacking fault energy decrease in austenitic stainless steels induced by hydrogen pairs formation  

Science Conference Proceedings (OSTI)

The decrease of the Stacking Fault Energy (SFE), induced by hydrogen in austenitic stainless steels, was always invoked to explain the formation of {epsilon}-martensite at room temperature during cathodic charging of hydrogen. Pontini and Hermida measured by XRD a reduction of 37 pct of the SPE of an AISI 304 steel at room temperature, in the presence of only 274 ppm of hydrogen. However, the nature of this phenomenon is still unknown. Recently, Obiol et a., using the Atoms Superposition and Electron Delocalization-Molecular Obital (ASED-MO) method, calculated the binding energy for H-H pair formation in the faulted zone of an FCC iron matrix. It was shown that, the H-H pair formation is more likely to occur along directions connecting octahedral interstices of the HCP stacking sequence and that are normal to the {l_brace}111{r_brace} planes. The binding energy found was {minus}5.75 eV, being this value significantly larger than the corresponding one for vacuum: {minus}4.75 eV. In this work, an explanation of the SFE decrease is developed on the basis of this previous result.

Hermida, J.D. [C.A.C.-CNEA, San Martin (Argentina). Dept. de Materiales] [C.A.C.-CNEA, San Martin (Argentina). Dept. de Materiales; Roviglione, A. [Faculty de Ingenieria, Uba (Argentina). Dept. de Ingenieria Mecanica y Naval] [Faculty de Ingenieria, Uba (Argentina). Dept. de Ingenieria Mecanica y Naval

1998-09-15T23:59:59.000Z

302

Feb. 11, 2008 Advanced Fault Tolerance Solutions for High Performance Computing 1/47 Advanced Fault Tolerance Solutions  

E-Print Network (OSTI)

Feb. 11, 2008 Advanced Fault Tolerance Solutions for High Performance Computing 1/47 RAS RAS Advanced Fault Tolerance Solutions for High Performance Computing Christian Engelmann Oak Ridge National Solutions for High Performance Computing 2/47 · Nation's largest energy laboratory · Nation's largest

Engelmann, Christian

303

Logs and paleoseismic interpretations from trenches 14C and 14D on the Bow Ridge fault, northeastern Yucca Mountain, Nye County, Nevada  

Science Conference Proceedings (OSTI)

Detailed studies of trenches 14D and 14C on the Bow Ridge fault indicate two to three displacements and long recurrence intervals during the middle to late Quaternary. The main trace of the fault is marked by a thick (20--40 centimeters wide) subvertical shear zone coated with multiple carbonate-silica laminae and several generations of fine-grained fissure-fill debris. Exposed in the trenches is a vertically stacked sequence of thin (0.3--1.5 meters thick) fine-grained colluvial, alluvial, and eolian deposits that commonly contain smaller wedge-shaped units or several weakly to strongly developed buried paleosols, or both. The two to three surface-rupture events are recognized at discrete stratigraphic intervals in the sequence based on (1) incremental up-section decreases in offset of marker horizons, (b) upward terminations of shear zones, fissure fills, and fractures, and (c) the position of small scarp-derived colluvial wedges deposited adjacent to the fault above downfaulted marker horizons. Preferred estimates of the vertical displacement per event are 12 and 40 centimeters. Left-oblique striations are observed on carbonate fault laminae, which, if tectonic in origin, increase the vertical displacement by factors of 1.1 to 1.7, yielding preferred net slip displacements per event of 13 to 70 centimeters. Thermoluminescence ages of 48 {+-} 20 and 132 {+-} 23 thousand years bracket the ages of the events, which probably occurred near the bounding ages of the time interval. These age constraints suggest long, average recurrence intervals between the three events of 75 to 210 ky; the preferred values range between 100 to 140 ky. The small net cumulative displacement of two dated reference horizons yield very low fault slip rates of 0.002 to 0.007 millimeters per year; the preferred value is 0.003 millimeters per year.

Menges, C.M.; Taylor, E.M.; Vadurro, G.; Oswald, J.A.; Cress, R.; Murray, M.; Lundstrom, S.C.; Paces, J.B.; Mahan, S.A.

1997-12-31T23:59:59.000Z

304

Steps toward fault-tolerant quantum chemistry.  

SciTech Connect

Developing quantum chemistry programs on the coming generation of exascale computers will be a difficult task. The programs will need to be fault-tolerant and minimize the use of global operations. This work explores the use a task-based model that uses a data-centric approach to allocate work to different processes as it applies to quantum chemistry. After introducing the key problems that appear when trying to parallelize a complicated quantum chemistry method such as coupled-cluster theory, we discuss the implications of that model as it pertains to the computational kernel of a coupled-cluster program - matrix multiplication. Also, we discuss the extensions that would required to build a full coupled-cluster program using the task-based model. Current programming models for high-performance computing are fault-intolerant and use global operations. Those properties are unsustainable as computers scale to millions of CPUs; instead one must recognize that these systems will be hierarchical in structure, prone to constant faults, and global operations will be infeasible. The FAST-OS HARE project is introducing a scale-free computing model to address these issues. This model is hierarchical and fault-tolerant by design, allows for the clean overlap of computation and communication, reducing the network load, does not require checkpointing, and avoids the complexity of many HPC runtimes. Development of an algorithm within this model requires a change in focus from imperative programming to a data-centric approach. Quantum chemistry (QC) algorithms, in particular electronic structure methods, are an ideal test bed for this computing model. These methods describe the distribution of electrons in a molecule, which determine the properties of the molecule. The computational cost of these methods is high, scaling quartically or higher in the size of the molecule, which is why QC applications are major users of HPC resources. The complexity of these algorithms means that MPI alone is insufficient to achieve parallel scaling; QC developers have been forced to use alternative approaches to achieve scalability and would be receptive to radical shifts in the programming paradigm. Initial work in adapting the simplest QC method, Hartree-Fock, to this the new programming model indicates that the approach is beneficial for QC applications. However, the advantages to being able to scale to exascale computers are greatest for the computationally most expensive algorithms; within QC these are the high-accuracy coupled-cluster (CC) methods. Parallel coupledcluster programs are available, however they are based on the conventional MPI paradigm. Much of the effort is spent handling the complicated data dependencies between the various processors, especially as the size of the problem becomes large. The current paradigm will not survive the move to exascale computers. Here we discuss the initial steps toward designing and implementing a CC method within this model. First, we introduce the general concepts behind a CC method, focusing on the aspects that make these methods difficult to parallelize with conventional techniques. Then we outline what is the computational core of the CC method - a matrix multiply - within the task-based approach that the FAST-OS project is designed to take advantage of. Finally we outline the general setup to implement the simplest CC method in this model, linearized CC doubles (LinCC).

Taube, Andrew Garvin

2010-05-01T23:59:59.000Z

305

Self field triggered superconducting fault current limiter  

DOE Patents (OSTI)

A superconducting fault current limiter array with a plurality of superconductor elements arranged in a meanding array having an even number of supconductors parallel to each other and arranged in a plane that is parallel to an odd number of the plurality of superconductors, where the odd number of supconductors are parallel to each other and arranged in a plane that is parallel to the even number of the plurality of superconductors, when viewed from a top view. The even number of superconductors are coupled at the upper end to the upper end of the odd number of superconductors. A plurality of lower shunt coils each coupled to the lower end of each of the even number of superconductors and a plurality of upper shunt coils each coupled to the upper end of each of the odd number of superconductors so as to generate a generally orthoganal uniform magnetic field during quenching using only the magenetic field generated by the superconductors.

Tekletsadik, Kasegn D. (Rexford, NY)

2008-02-19T23:59:59.000Z

306

Fault tolerant hypercube computer system architecture  

SciTech Connect

This patent describes a fault-tolerant multi-processor computer system of the hypercube type. It comprises: a plurality of first computing nodes; a first network of message conducting path means for interconnecting the first computing nodes as a hypercube. The first network providing a path for message transfer between the first computing nodes; a first watch dog node; and, a second network of message conducting path means for directly connecting each of the first computing nodes to the first watch dog node independent from the first network. The second network providing an independent path for test message and reconfiguration affecting transfers between respective ones of the first computing nodes and the first watch dog node.

Madan, H.S.; Chow, E.

1989-09-19T23:59:59.000Z

307

Wavelet analysis for gas turbine fault diagnostics  

SciTech Connect

The application of wavelet analysis to diagnosing faults in gas turbines is examined in the present paper. Applying the wavelet transform to time signals obtained from sensors placed on an engine gives information in correspondence to their Fourier transform. Diagnostic techniques based on Fourier analysis of signals can therefore be transposed to the wavelet analysis. In the paper the basic properties of wavelets, in relation to the nature of turbomachinery signals, are discussed. The possibilities for extracting diagnostic information by means of wavelets are examined, by studying the applicability to existing data from vibration, unsteady pressure, and acoustic measurements. Advantages offered, with respect to existing methods based on harmonic analysis, are discussed as well as particular requirements related to practical application.

Aretakis, N.; Mathioudakis, K. [National Technical Univ. of Athens (Greece). Lab. of Thermal Turbomachines

1997-10-01T23:59:59.000Z

308

Character and regional significance of Great Falls Tectonic Zone, East-Central Idaho and West-Central Montana  

SciTech Connect

The Great Falls tectonic zone, here named, is a belt of diverse northeast-trending geologic features that can be traced from the Idaho batholith in the Cordilleran miogeocline, across thrust-belt structures and basement rocks of west-central and southwestern Montana, through cratonic rocks of central Montana, and into southwesternmost Saskatchewan, Canada. Geologic mapping in east-central Idaho and west-central Montana has outlined a continuous zone of high-angle faults and shear zones. These structures extend more than 150 km northeastward from near Salmon, Idaho, toward Anaconda, Montana, had recurrent movement from middle Proterozoic to Holocene time, controlled the intrusion and orientation of Late Cretaceous to early Tertiary dike swarms, and controlled the uplift and orientation of the Anaconda-Pintlar Range. Recurrent fault movement in this zone and strong structural control over igneous intrusion suggest a fundamental tectonic feature that has influenced the tectonic development of the Idaho Montana area from at least middle Proterozoic time to the present.

O'Neill, J.M.; Lopez, D.A.

1985-03-01T23:59:59.000Z

309

The Border Cities Enterprise Zone Program (Minnesota)  

Energy.gov (U.S. Department of Energy (DOE))

The Border Cities Enterprise Zone Program provides business tax credits to businesses that invest, develop, expand, and create jobs in identified Border-Cities Enterprise Zones. Companies may be...

310

Enterprise Zone Real Property Investment Grant (Virginia)  

Energy.gov (U.S. Department of Energy (DOE))

The Enterprise Zone Real Property Investment Grantprovides qualified zone investors with cash grants for industrial, commercial or mixed use property. The grant is equal to 20% of the excess...

311

Enterprise Zone Sales Tax Exemption (Kansas)  

Energy.gov (U.S. Department of Energy (DOE))

The Enterprise Zone Sales Tax Exemption offers businesses located in such economic development zones a 100 percent sales tax exemption on the purchase of labor and materials to construct or remodel...

312

MICRO-SEISMICITY, FAULT STRUCTURE AND HYDRAULIC COMPARTMENTALIZATION WITHIN  

Open Energy Info (EERE)

MICRO-SEISMICITY, FAULT STRUCTURE AND HYDRAULIC COMPARTMENTALIZATION WITHIN MICRO-SEISMICITY, FAULT STRUCTURE AND HYDRAULIC COMPARTMENTALIZATION WITHIN THE COSO GETHERMAL FIELD, CALIFORNIA Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Conference Proceedings: MICRO-SEISMICITY, FAULT STRUCTURE AND HYDRAULIC COMPARTMENTALIZATION WITHIN THE COSO GETHERMAL FIELD, CALIFORNIA Details Activities (1) Areas (1) Regions (0) Abstract: High precision earthquake locations and subsurface velocity structure provide potential insights into fracture system geometry, fluid conduits and fluid compartmentalization critical to geothermal reservoir management. We analyze 16 years of seismicity to improve hypocentral locations and simultaneously invert for the seismic velocity structure within the Coso Geothermal Field (CGF). The CGF has been continuously

313

Soft Computing Application in Fault Detection of Induction Motor  

Science Conference Proceedings (OSTI)

The paper investigates the effectiveness of different patter classifier like Feed Forward Back Propagation (FFBPN), Radial Basis Function (RBF) and Support Vector Machine (SVM) for detection of bearing faults in Induction Motor. The steady state motor current with Park's Transformation has been used for discrimination of inner race and outer race bearing defects. The RBF neural network shows very encouraging results for multi-class classification problems and is hoped to set up a base for incipient fault detection of induction motor. SVM is also found to be a very good fault classifier which is highly competitive with RBF.

Konar, P.; Puhan, P. S.; Chattopadhyay, P. Dr. [Electrical Engineering Department, BESUS, Shibpur (India)

2010-10-26T23:59:59.000Z

314

Gulf of California Rift Zone Geothermal Region | Open Energy...  

Open Energy Info (EERE)

of California Rift Zone Geothermal Region (Redirected from Gulf of California Rift Zone) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Gulf of California Rift Zone...

315

Allegan County, Michigan ASHRAE 169-2006 Climate Zone | Open...  

Open Energy Info (EERE)

Allegan County, Michigan ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Allegan County, Michigan ASHRAE Standard ASHRAE 169-2006 Climate Zone...

316

Becker County, Minnesota ASHRAE 169-2006 Climate Zone | Open...  

Open Energy Info (EERE)

Becker County, Minnesota ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Becker County, Minnesota ASHRAE Standard ASHRAE 169-2006 Climate Zone...

317

Anchorage Borough, Alaska ASHRAE 169-2006 Climate Zone | Open...  

Open Energy Info (EERE)

Anchorage Borough, Alaska ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Anchorage Borough, Alaska ASHRAE Standard ASHRAE 169-2006 Climate Zone...

318

Benton County, Tennessee ASHRAE 169-2006 Climate Zone | Open...  

Open Energy Info (EERE)

Tennessee ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Benton County, Tennessee ASHRAE Standard ASHRAE 169-2006 Climate Zone Number Climate...

319

Arapahoe County, Colorado ASHRAE 169-2006 Climate Zone | Open...  

Open Energy Info (EERE)

Arapahoe County, Colorado ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Arapahoe County, Colorado ASHRAE Standard ASHRAE 169-2006 Climate Zone...

320

Alfalfa County, Oklahoma ASHRAE 169-2006 Climate Zone | Open...  

Open Energy Info (EERE)

Alfalfa County, Oklahoma ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Alfalfa County, Oklahoma ASHRAE Standard ASHRAE 169-2006 Climate Zone...

Note: This page contains sample records for the topic "madrid fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Augusta County, Virginia ASHRAE 169-2006 Climate Zone | Open...  

Open Energy Info (EERE)

Augusta County, Virginia ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Augusta County, Virginia ASHRAE Standard ASHRAE 169-2006 Climate Zone...

322

Benton County, Minnesota ASHRAE 169-2006 Climate Zone | Open...  

Open Energy Info (EERE)

Minnesota ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Benton County, Minnesota ASHRAE Standard ASHRAE 169-2006 Climate Zone Number Climate...

323

Barron County, Wisconsin ASHRAE 169-2006 Climate Zone | Open...  

Open Energy Info (EERE)

Barron County, Wisconsin ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Barron County, Wisconsin ASHRAE Standard ASHRAE 169-2006 Climate Zone...

324

Bedford County, Tennessee ASHRAE 169-2006 Climate Zone | Open...  

Open Energy Info (EERE)

Bedford County, Tennessee ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Bedford County, Tennessee ASHRAE Standard ASHRAE 169-2006 Climate Zone...

325

Audrain County, Missouri ASHRAE 169-2006 Climate Zone | Open...  

Open Energy Info (EERE)

Audrain County, Missouri ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Audrain County, Missouri ASHRAE Standard ASHRAE 169-2006 Climate Zone...

326

Anderson County, Kentucky ASHRAE 169-2006 Climate Zone | Open...  

Open Energy Info (EERE)

Anderson County, Kentucky ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Anderson County, Kentucky ASHRAE Standard ASHRAE 169-2006 Climate Zone...

327

Adams County, Pennsylvania ASHRAE 169-2006 Climate Zone | Open...  

Open Energy Info (EERE)

Pennsylvania ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Adams County, Pennsylvania ASHRAE Standard ASHRAE 169-2006 Climate Zone Number...

328

Ballard County, Kentucky ASHRAE 169-2006 Climate Zone | Open...  

Open Energy Info (EERE)

Ballard County, Kentucky ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Ballard County, Kentucky ASHRAE Standard ASHRAE 169-2006 Climate Zone...

329

Ashland County, Wisconsin ASHRAE 169-2006 Climate Zone | Open...  

Open Energy Info (EERE)

Ashland County, Wisconsin ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Ashland County, Wisconsin ASHRAE Standard ASHRAE 169-2006 Climate Zone...

330

Accomack County, Virginia ASHRAE 169-2006 Climate Zone | Open...  

Open Energy Info (EERE)

Accomack County, Virginia ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Accomack County, Virginia ASHRAE Standard ASHRAE 169-2006 Climate Zone...

331

Benton County, Washington ASHRAE 169-2006 Climate Zone | Open...  

Open Energy Info (EERE)

Washington ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Benton County, Washington ASHRAE Standard ASHRAE 169-2006 Climate Zone Number Climate...

332

Asotin County, Washington ASHRAE 169-2006 Climate Zone | Open...  

Open Energy Info (EERE)

Asotin County, Washington ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Asotin County, Washington ASHRAE Standard ASHRAE 169-2006 Climate Zone...

333

Enterprise Zones (Iowa) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Zones (Iowa) Zones (Iowa) Enterprise Zones (Iowa) < Back Eligibility Agricultural Commercial Construction Fuel Distributor Industrial Installer/Contractor Institutional Investor-Owned Utility Municipal/Public Utility Nonprofit Rural Electric Cooperative Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Iowa Program Type Enterprise Zone Industry Recruitment/Support Training/Technical Assistance Provider Iowa Economic Development Authority The Enterprise Zones Program is an incentive for business expansion designed to stimulate development by targeting economically distressed areas in Iowa. Through state and local tax incentives, businesses and developers are encouraged to make new investments, and create or retain

334

Enterprise Zone Program (Georgia) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Georgia) Georgia) Enterprise Zone Program (Georgia) < Back Eligibility Agricultural Commercial Construction Developer Fuel Distributor General Public/Consumer Industrial Installer/Contractor Investor-Owned Utility Municipal/Public Utility Retail Supplier Rural Electric Cooperative Systems Integrator Transportation Tribal Government Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Georgia Program Type Enterprise Zone Personal Tax Incentives Property Tax Incentive Provider Georgia Department of Community Affairs The Enterprise Zone Program provides various tax incentives to businesses within designated underdeveloped zones in rural or urban areas. The State Enterprise Zone program intends to improve geographic areas within cities

335

Geothermal Lost Circulation Zone Mapping Tool  

DOE Green Energy (OSTI)

Lost circulation is an expensive and often encountered problem when drilling into geothermal formations. A method is needed to more accurately describe loss zones encountered during geothermal drilling to allow for more realistic testing since present testing techniques are inadequate. A Lost Circulation Zone Mapping Tool (LCZMT) is being developed that will quickly locate a loss zone and then provide a visual image of this zone as it intersects the wellbore. A modified Sandia high temperature Acoustic Borehole Televiewer should allow modeling of geothermal loss zones, which would in turn lead to testing that can be performed to evaluate lost circulation materials under simulated downhole conditions. 5 refs., 5 figs.

Bauman, T.J.

1985-01-01T23:59:59.000Z

336

Fault Detection and Isolation of a Cryogenic Rocket Engine Combustion Chamber Using a Parity Space Approach  

Science Conference Proceedings (OSTI)

his paper presents a parity space (PS) approach for fault detection and isolation (FDI) of a cryogenic rocket engine combustion chamber. Nominal and non-nominal simulation data for three engine set points have been provided. The PS approach uses three ... Keywords: Fault Detection, Fault Isolation, Fault Diagnosis, Parity Space, Rocket Engine

Paul van Gelder; Andr Bos

2009-07-01T23:59:59.000Z

337

A Systematic Stochastic Petri Net Based Methodology for Transformer Fault Diagnosis and Repair Actions  

Science Conference Proceedings (OSTI)

Transformer fault diagnosis and repair is a complex task that includes many possible types of faults and demands special trained personnel. Moreover, the minimization of the time needed for transformer fault diagnosis and repair is an important task ... Keywords: power system reliability, stochastic petri nets, transformer fault diagnosis

P. S. Georgilakis; J. A. Katsigiannis; K. P. Valavanis; A. T. Souflaris

2006-02-01T23:59:59.000Z

338

Fault-based test suite prioritization for specification-based testing  

Science Conference Proceedings (OSTI)

Context: Existing test suite prioritization techniques usually rely on code coverage information or historical execution data that serve as indicators for estimating the fault-detecting ability of test cases. Such indicators are primarily empirical in ... Keywords: Fault class hierarchy, Fault-based prioritization, Fault-based testing, Software testing, Specification-based testing, Test suite prioritization

Yuen Tak Yu; Man Fai Lau

2012-02-01T23:59:59.000Z

339

A Power Transmission Line Fault Distance Estimation VLSI Chip: Design and Defect Tolerance  

Science Conference Proceedings (OSTI)

This paper presents a system-on-a-chip for fault detection and fault-distance-estimation for power transmission lines in the smart grid. Toward this goal we have designed and fabricated three chips: PGS4, PGS5 and PGS6, each successively more advanced ... Keywords: Smart grid, fault distance, arcing fault, system on a chip, defect tolerance, Radojevic algorithm.

E. MacLean; V. K. Jain

2011-10-01T23:59:59.000Z

340

Property:ASHRAE 169 Climate Zone Number | Open Energy Information  

Open Energy Info (EERE)

Number Number Jump to: navigation, search This is a property of type Page. Pages using the property "ASHRAE 169 Climate Zone Number" Showing 25 pages using this property. (previous 25) (next 25) A Abbeville County, South Carolina ASHRAE 169-2006 Climate Zone + Climate Zone Number 3 + Acadia Parish, Louisiana ASHRAE 169-2006 Climate Zone + Climate Zone Number 2 + Accomack County, Virginia ASHRAE 169-2006 Climate Zone + Climate Zone Number 4 + Ada County, Idaho ASHRAE 169-2006 Climate Zone + Climate Zone Number 5 + Adair County, Iowa ASHRAE 169-2006 Climate Zone + Climate Zone Number 5 + Adair County, Kentucky ASHRAE 169-2006 Climate Zone + Climate Zone Number 4 + Adair County, Missouri ASHRAE 169-2006 Climate Zone + Climate Zone Number 5 + Adair County, Oklahoma ASHRAE 169-2006 Climate Zone + Climate Zone Number 3 +

Note: This page contains sample records for the topic "madrid fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Property:ASHRAE 169 Climate Zone Subtype | Open Energy Information  

Open Energy Info (EERE)

ASHRAE 169 Climate Zone Subtype ASHRAE 169 Climate Zone Subtype Jump to: navigation, search This is a property of type Page. Pages using the property "ASHRAE 169 Climate Zone Subtype" Showing 25 pages using this property. (previous 25) (next 25) A Abbeville County, South Carolina ASHRAE 169-2006 Climate Zone + Climate Zone Subtype A + Acadia Parish, Louisiana ASHRAE 169-2006 Climate Zone + Climate Zone Subtype A + Accomack County, Virginia ASHRAE 169-2006 Climate Zone + Climate Zone Subtype A + Ada County, Idaho ASHRAE 169-2006 Climate Zone + Climate Zone Subtype B + Adair County, Iowa ASHRAE 169-2006 Climate Zone + Climate Zone Subtype A + Adair County, Kentucky ASHRAE 169-2006 Climate Zone + Climate Zone Subtype A + Adair County, Missouri ASHRAE 169-2006 Climate Zone + Climate Zone Subtype A +

342

Zoned heating and air conditioning system  

SciTech Connect

This patent describes a zoned heating and air conditioning system comprising: a central air handling system with an air heating means and an air cooling means and a blower connected to an air duct system; thermostats each have heating and cooling set points, respectively associated with and located in different zones of a building; dampers respectively associated with each building zone positioned in the air duct system. Each damper has an open position allowing air into the respective zone from the duct system and a closed position; relay means for connecting one thermostat to the air handling system upon a call for heating or cooling by one thermostat and disconnecting all other thermostats by connecting one thermostat's connections between the thermostat and air handling system. Only one thermostat is connected to the air handling system at a time and the relay means disconnects one thermostat from the air handling system after one thermostat is satisified; and damper actuating means for unlocking each damper in one building zone responsive actuated by a respective zone thermostat connected to the air handling system by the relay means. The damper actuates means including a damper solenoid for each damper located adjacent each damper and connected to a respective zone thermostat. It unlocks each damper in one building zone responsive to being actuated by the respective zone thermostat and unlocks the dampers in one building zone when one thermostat is actuated while preventing the dampers in another thermostat's building zone from unlocking.

Beachboard, S.A.

1987-06-16T23:59:59.000Z

343

Overview: Zoning for Small Wind Turbines  

Wind Powering America (EERE)

Overview: Overview: Zoning for Small Wind Turbines Jim Green NREL ASES Small Wind Division Webinar January 17, 2008 2 Zoning Basics * Zoning is one form of land use law * Based on legal principle of "police power:" the power to regulate in order to promote the health, morals, safety, and general welfare of the community * Zoning authority originates from state laws called "zoning enabling legislation" - Standard Zoning Enabling Act, Dept. of Commerce, 1920s * Enabling legislation delegates land use authority to local jurisdictions, "Home Rule" - counties, parishes, boroughs, townships, municipalities, cities, villages, etc. 3 Zoning is Daunting * 3,034 counties (National Association of Counties) * 16,504 townships * 19,429 municipalities (National League of Cities)

344

Enhanced Enterprise Zones (Missouri) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Enhanced Enterprise Zones (Missouri) Enhanced Enterprise Zones (Missouri) Enhanced Enterprise Zones (Missouri) < Back Eligibility Commercial Industrial Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Missouri Program Type Enterprise Zone Corporate Tax Incentive Provider Missouri Department of Economic Development Enhanced Enterprise Zones aim at attracting new businesses or promoting an expansion of existing business in Missouri Enhanced Enterprise Zone. Tax credits will be an amount authorized by DED, based on the state economic benefit, supported by the number of new jobs, wages and new capital investment that the project will create. To qualify, individual business eligibility will be determined by the zone, based on creation of

345

Recency Of Faulting And Neotechtonic Framework In The Dixie Valley  

Open Energy Info (EERE)

Of Faulting And Neotechtonic Framework In The Dixie Valley Of Faulting And Neotechtonic Framework In The Dixie Valley Geothermal Field And Other Geothermal Fields Of The Basin And Range Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Report: Recency Of Faulting And Neotechtonic Framework In The Dixie Valley Geothermal Field And Other Geothermal Fields Of The Basin And Range Details Activities (6) Areas (3) Regions (0) Abstract: We studied the role that earthquake faults play in redistributing stresses within in the earths crust near geothermal fields. The geographic foci of our study were the sites of geothermal plants in Dixie Valley, Beowawe, and Bradys Hot Springs, Nevada. Our initial results show that the past history of earthquakes has redistributed stresses at these 3 sites in a manner to open and maintain fluid pathways critical for geothermal

346

Understanding Fault Characteristics And Sediment Depth For Geothermal  

Open Energy Info (EERE)

Understanding Fault Characteristics And Sediment Depth For Geothermal Understanding Fault Characteristics And Sediment Depth For Geothermal Exploration Using 3D Gravity Inversion In Walker Valley, Nevada Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Conference Paper: Understanding Fault Characteristics And Sediment Depth For Geothermal Exploration Using 3D Gravity Inversion In Walker Valley, Nevada Details Activities (2) Areas (1) Regions (0) Abstract: The Southern Walker Lake Basin, situated in the Walker Lake structural domain, consists of primarily E-W directed extension along N-NNW striking normal faults. Water well drilling on the eastern slopes of the Wassuk Range, west of the city of Hawthorne, Nevada showed elevated temperatures. Two recent drill holes reaching downhole depths of more than 4000 ft give some insight to the geologic picture, but more information

347

Fault Detection and Isolation in Low-Voltage DC Distribution ...  

A University of Colorado research team led by Jae-Do Park has developed a fault detection and isolation scheme for a low-voltage DC-bus microgrid system, ...

348

Recency of Faulting and Neotectonic Framework in the Dixie Valley  

Open Energy Info (EERE)

of Faulting and Neotectonic Framework in the Dixie Valley of Faulting and Neotectonic Framework in the Dixie Valley Geothermal Field and Other Geothermal Fields of the Basin and Range Jump to: navigation, search OpenEI Reference LibraryAdd to library Report: Recency of Faulting and Neotectonic Framework in the Dixie Valley Geothermal Field and Other Geothermal Fields of the Basin and Range Abstract We studied the role that earthquake faults play in redistributing stresses within in the earths crust near geothermal fields. The geographic foci of our study were the sites of geothermal plants in Dixie Valley, Beowawe, and Bradys Hot Springs, Nevada. Our initial results show that the past history of earthquakes has redistributed stresses at these 3 sites in a manner to open and maintain fluid pathways critical for geothermal development. The

349

Aksaray And Ecemis Faults - Diapiric Salt Relationships- Relevance To The  

Open Energy Info (EERE)

Aksaray And Ecemis Faults - Diapiric Salt Relationships- Relevance To The Aksaray And Ecemis Faults - Diapiric Salt Relationships- Relevance To The Hydrocarbon Exploration In The Tuz Golu (Salt Lake) Basin, Central Anatolia, Turkey Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: Aksaray And Ecemis Faults - Diapiric Salt Relationships- Relevance To The Hydrocarbon Exploration In The Tuz Golu (Salt Lake) Basin, Central Anatolia, Turkey Details Activities (0) Areas (0) Regions (0) Abstract: Due to activitiy of the Aksaray and Ecemis Faults, volcanic intrusion and westward movement of the Anatolian plate, diapiric salt structures were occurred in the Tuz Golu (Salt Lake) basin in central Anatolia, Turkey. With the collisions of the Arabian and Anatolian plates during the late Cretaceous and Miocene times, prominent ophiolitic

350

Fusing strategies for the dual-voltage fault  

E-Print Network (OSTI)

This thesis focuses on the 42V - 14V fault in a dual voltage system and discusses the possibility of effective fusing. A simple model for the system had been created from technical documentation. Based on the model and the ...

Shrivastava, Rupam, 1981-

2005-01-01T23:59:59.000Z

351

Local discriminant bases in machine fault diagnosis using vibration signals  

Science Conference Proceedings (OSTI)

Wavelets and local discriminant bases (LDB) selection algorithm is applied to vibration signals in a single-cylinder spark ignition engine for feature extraction and fault classification. LDB selects a complete orthogonal basis from a wavelet packet ...

R. Tafreshi; F. Sassani; H. Ahmadi; G. Dumont

2005-04-01T23:59:59.000Z

352

Adaptive Control and Fault Detection of HVAC Equipment in Commercial...  

NLE Websites -- All DOE Office Websites (Extended Search)

Adaptive Control and Fault Detection of HVAC Equipment in Commercial Buildings Speaker(s): John Seem Date: February 27, 2002 - 12:00pm Location: Bldg. 90 Seminar HostPoint of...

353

Non-intrusive fault detection in reciprocating compressors  

E-Print Network (OSTI)

This thesis presents a set of techniques for non-intrusive sensing and fault detection in reciprocating compressors driven by induction motors. The procedures developed here are "non-intrusive" because they rely only on ...

Schantz, Christopher James

2011-01-01T23:59:59.000Z

354

Discretized streams: fault-tolerant streaming computation at scale  

Science Conference Proceedings (OSTI)

Many "big data" applications must act on data in real time. Running these applications at ever-larger scales requires parallel platforms that automatically handle faults and stragglers. Unfortunately, current distributed stream processing models provide ...

Matei Zaharia, Tathagata Das, Haoyuan Li, Timothy Hunter, Scott Shenker, Ion Stoica

2013-11-01T23:59:59.000Z

355

High-Resolution Aeromagnetic Survey to Image Shallow Faults,...  

Open Energy Info (EERE)

Number 02-384 DOI Not Provided Check for DOI availability: http:crossref.org Online Internet link for High-Resolution Aeromagnetic Survey to Image Shallow Faults, Dixie Valley...

356

Understanding Fault Characteristics And Sediment Depth For Geothermal...  

Open Energy Info (EERE)

of primarily E-W directed extension along N-NNW striking normal faults. Water well drilling on the eastern slopes of the Wassuk Range, west of the city of Hawthorne, Nevada...

357

Characteristics of Wind Turbines Under Normal and Fault Conditions: Preprint  

SciTech Connect

This paper investigates the characteristics of a variable-speed wind turbine connected to a stiff or weak grid under normal and fault conditions and the role of reactive power compensation.

Muljadi, E.; Butterfield, C. P.; Parsons, B.; Ellis, A.

2007-02-01T23:59:59.000Z

358

CAPRI: A Common Architecture for Distributed Probabilistic Internet Fault Diagnosis  

E-Print Network (OSTI)

This thesis presents a new approach to root cause localization and fault diagnosis in the Internet based on a Common Architecture for Probabilistic Reasoning in the Internet (CAPRI) in which distributed, heterogeneous ...

Lee, George J.

2007-06-04T23:59:59.000Z

359

Microgrid Fault Protection Based on Symmetrical and Differential Current Components  

E-Print Network (OSTI)

Microgrid Fault Protection Based on Symmetrical and Differential Current Components Prepared.........................................................................................8 2. AEP CERTS MICROGRID .........................................................................9 ........................................................................67 #12;3 Index of Figures Figure 1: Schematic representation of the AEP CERTS microgrid

360

A Fault Detection and Diagnosis Method for HVAC Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

A Fault Detection and Diagnosis Method for HVAC Systems A Fault Detection and Diagnosis Method for HVAC Systems Speaker(s): Peng Xu Date: December 2, 2002 - 12:00pm Location: Bldg. 90 There is a growing consensus that most buildings do not perform as well as intended and that faults in HVAC systems are widespread in commercial buildings. An automated fault detection and diagnosis tool for HVAC systems is being developed, based on an integrated, life-cycle, approach to commissioning and performance monitoring. The tool uses component-level HVAC equipment models implemented in the SPARK equation-based simulation environment. The models are configured using design information and component manufacturers' data and then fine-tuned to match the actual performance of the equipment by using data measured during functional tests

Note: This page contains sample records for the topic "madrid fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Fault Mapping At Coso Geothermal Area (1980) | Open Energy Information  

Open Energy Info (EERE)

Fault Mapping At Coso Geothermal Area (1980) Fault Mapping At Coso Geothermal Area (1980) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Fault Mapping At Coso Geothermal Area (1980) Exploration Activity Details Location Coso Geothermal Area Exploration Technique Fault Mapping Activity Date 1980 Usefulness useful DOE-funding Unknown Exploration Basis To determine the Late Cenozoic volcanism, geochronology, and structure of the Coso Range Notes This system apparently is heated by a reservoir of silicic magma at greater than or equal to 8-km depth, itself produced and sustained through partial melting of crustal rocks by thermal energy contained in mantle-derived basaltic magma that intrudes the crust in repsonse to lithospheric extension. References Duffield, W.A.; Bacon, C.R.; Dalrymple, G.B. (10 May 1980) Late

362

Dynamic transient fault detection and recovery for embedded processor datapaths  

Science Conference Proceedings (OSTI)

As microprocessors continue to evolve and grow in functionality, the use of smaller nanometer technology scaling coupled with high clock frequencies and exponentially increasing transistor counts dramatically increases the susceptibility of transient ... Keywords: datapath, embedded, fault tolerance, reliability, soft errors

Garo Bournoutian; Alex Orailoglu

2012-10-01T23:59:59.000Z

363

Transmission Line Fault Inspection and Root Cause Analysis Approach  

Science Conference Proceedings (OSTI)

Transmission lines are designed to transfer electric power from source locations, sometimes over great distances through different terrains and exposed to several influences. These challenges include faulty equipment, misoperation, human errors, and aging of components, as well as meteorological and ecological factors such as storms, lightning, and the effects of plants and animals. A number of techniques are currently used to isolate the faulting line and provide the fault position. Sustained or ...

2013-12-20T23:59:59.000Z

364

The application of satellite time references to HVDC fault location  

Science Conference Proceedings (OSTI)

An HVdc fault location scheme is described which relies on very precise detection of the time of arrival of fault created surges at both ends of the line. Such detection is achieved by a very accurate data acquisition and processing system combined with the time reference signals provided by a global positioning system receiver. Extensive digital simulation is carried out to determine the voltage and current waveforms, to identify the main sources of error and suggest possible compensation techniques.

Dewe, M.B.; Sankar, S.; Arrillaga, J. (Univ. of Canterbury, Christchurch (New Zealand))

1993-07-01T23:59:59.000Z

365

Transmission Line Fault Inspection and Root Cause Analysis Approach  

Science Conference Proceedings (OSTI)

Transmission lines are designed to transfer electric power from source locations sometimes over great distances through different terrains and exposed to several influences. These challenges include faulty equipment, misoperation, human errors, and aging of components, and meteorological and ecological factors such as storms, lightning, and the effects of plants and animals. A number of techniques are currently used to isolate the faulting line and provide the fault position. Sustained or permanent ...

2012-12-20T23:59:59.000Z

366

Fault-tolerance for exascale systems.  

Science Conference Proceedings (OSTI)

Periodic, coordinated, checkpointing to disk is the most prevalent fault tolerance method used in modern large-scale, capability class, high-performance computing (HPC) systems. Previous work has shown that as the system grows in size, the inherent synchronization of coordinated checkpoint/restart (CR) limits application scalability; at large node counts the application spends most of its time checkpointing instead of executing useful work. Furthermore, a single component failure forces an application restart from the last correct checkpoint. Suggested alternatives to coordinated CR include uncoordinated CR with message logging, redundant computation, and RAID-inspired, in-memory distributed checkpointing schemes. Each of these alternatives have differing overheads that are dependent on both the scale and communication characteristics of the application. In this work, using the Structural Simulation Toolkit (SST) simulator, we compare the performance characteristics of each of these resilience methods for a number of HPC application patterns on a number of proposed exascale machines. The result of this work provides valuable guidance on the most efficient resilience methods for exascale systems.

Riesen, Rolf E.; Varela, Maria Ruiz (University of Delaware); Ferreira, Kurt Brian

2010-08-01T23:59:59.000Z

367

Algorithmic Based Fault Tolerance Applied to High Performance Computing  

E-Print Network (OSTI)

We present a new approach to fault tolerance for High Performance Computing system. Our approach is based on a careful adaptation of the Algorithmic Based Fault Tolerance technique (Huang and Abraham, 1984) to the need of parallel distributed computation. We obtain a strongly scalable mechanism for fault tolerance. We can also detect and correct errors (bit-flip) on the fly of a computation. To assess the viability of our approach, we have developed a fault tolerant matrix-matrix multiplication subroutine and we propose some models to predict its running time. Our parallel fault-tolerant matrix-matrix multiplication scores 1.4 TFLOPS on 484 processors (cluster jacquard.nersc.gov) and returns a correct result while one process failure has happened. This represents 65% of the machine peak efficiency and less than 12% overhead with respect to the fastest failure-free implementation. We predict (and have observed) that, as we increase the processor count, the overhead of the fault tolerance drops significantly.

Bosilca, George; Dongarra, Jack; Langou, Julien

2008-01-01T23:59:59.000Z

368

Designing fault-tolerant manipulators: How many degrees of freedom?  

SciTech Connect

One of the most important parameters to consider when designing a manipulator is the number of degrees of freedom (DOFs). This article focuses on the question: How many DOFs are necessary and sufficient for fault tolerance, and how should these DOFs be distributed along the length of the manipulator? A manipulator is fault tolerant if it can complete its task even when one of its joints fails and is immobilized. The number of DOFs needed for fault tolerance strongly depends on the knowledge available about the task. In this article, two approaches are explored. First, for the design of a general purpose fault-tolerant manipulator, it is assumed that neither the exact task trajectory nor the redundancy resolution algorithm are known a priori and the manipulator has no joint limits. In this case, two redundant DOFs are necessary and sufficient to sustain one joint failure, as is demonstrated in two design templates for spatial fault-tolerant manipulators. In this second approach, both the Cartesian task path and the redundancy resolution algorithm are assumed to be known. The design of such a task-specific fault-tolerant manipulator requires only one degree of redundancy. 22 refs., 11 figs., 2 tabs.

Paredis, C.J.J.; Khosla, P.K. [Carnegie Mellon Univ., Pittsburgh, PA (United States)

1996-12-01T23:59:59.000Z

369

U.S. Climate Zones Map for Commercial Buildings  

U.S. Energy Information Administration (EIA) Indexed Site

Past Climate Zones U. S. Climate Zones for 1979-1999 CBECS: climate zone map Return to Climate Zones for 2003 CBECS Return to CBECS Home Page Note:Map updated with corrections,...

370

U.S. Climate Zones Map for Commercial Buildings  

U.S. Energy Information Administration (EIA) Indexed Site

U.S. Climate Zone U. S. Climate Zones for 2003 CBECS: climate zones map Note:Map updated with corrections, February 2012 Further Explanation on How Climate Zones are Defined...

371

Property:Buildings/ModelClimateZone | Open Energy Information  

Open Energy Info (EERE)

ModelClimateZone ModelClimateZone Jump to: navigation, search This is a property of type Page. It links to pages that use the form Buildings Model. The allowed values for this property are: Climate Zone 1A Climate Zone 1B Climate Zone 2A Climate Zone 2B Climate Zone 3A Climate Zone 3B Climate Zone 3C Climate Zone 4A Climate Zone 4B Climate Zone 4C Climate Zone 5A Climate Zone 5B Climate Zone 5C Climate Zone 6A Climate Zone 6B Climate Zone 7A Climate Zone 7B Climate Zone 8A Climate Zone 8B Pages using the property "Buildings/ModelClimateZone" Showing 12 pages using this property. G General Merchandise 2009 TSD Chicago High Plug Load 50% Energy Savings + Climate Zone 5A + General Merchandise 2009 TSD Chicago High Plug Load Baseline + Climate Zone 5A + General Merchandise 2009 TSD Chicago Low Plug Load 50% Energy Savings + Climate Zone 5A +

372

Palaeoseismology of the North Anatolian Fault near the Marmara Sea: implications for fault segmentation and seismic hazard  

E-Print Network (OSTI)

Diego, CA 92182, USA 2 Institute of Geological and Nuclear Sciences, PO Box 30-368, Lower Hutt, New fault to the city of Istanbul, one of the largest cities in the Middle East. Across the 1912 rupture

Klinger, Yann

373

Evaluation of faulting characteristics and ground acceleration associated with recent movement along the Meers Fault, Southwestern Oklahoma  

E-Print Network (OSTI)

Recent studies have shown that a 27 km section of the Meers Fault was reactivated during Holocene time. Although these studies have proven the occurrence of recent fault activity, many basic characteristics of the faulting remain unresolved, For instance, the issue of whether recent deformation was dominantly vertical or laterally oriented is still a source of disagreement among many researchers. The number of events associated with recent movement is another area of uncertainty, with I to 4 events being cited as responsible for the Meers Fault scarp. Earthquakes of magnitude 7 to 8 occurring in conjunction with recent reactivation of the fault have been calculated. However, evidence found within the Wichita Mountains just south of the fault exhibits strong evidence against large recent earthquake events. Investigation of stream channel pathways where they cross the fault revealed that many streams previously identified as left-laterally offset are instead left-laterally deflected by folding on the upthrown block. These streams are in every case deflected much farther than any true lateral displacement recognized on the fault. Inclusion of the streams in past studies has apparently contributed to over-estimation of the recent component of left-lateral displacement. Exposure development into the Meers Fault scarp revealed deformed units and colluvial wedges that indicate 4 recent movements produced a total of 1.46 m of brittle deformation and another 1.04 m of monoclinal warping. A previously unidentified conglomerate uncovered in the exposure exhibits evidence for a lateral component of displacement during possible Late Pleistocene deformation. subsequent events identified in the exposure. Reconnaissance of the Wichita Mountains granitic terrain just south of the Meers Fault resulted in the identification of 27 precariously balanced rocks (tors). These geomorphic features lie within 18 km of the fault and have apparently been sitting in their present positions on the order of thousands of years. Quantitative analysis of the tors indicates that most could not have withstood the ground accelerations generated by magnitude 7 or above earthquakes estimated to have occurred with recent deformation.

Burrell, Richard Dennis

1997-01-01T23:59:59.000Z

374

Reactive geothermal transport simulation to study the formation mechanism of impermeable barrier between acidic and neutral fluid zones in the Onikobe Geothermal Field, Japan  

DOE Green Energy (OSTI)

Two types of fluids are encountered in the Onikobe geothermal reservoir, one is neutral and the other is acidic (pH=3). It is hypothesized that acidic fluid might be upwelling along a fault zone and that an impermeable barrier might be present between the acidic and neutral fluid zones. We carried out reactive geothermal transport simulations using TOUGHREACT (Xu and Pruess, 1998 and 2001) to test such a conceptual model. Mn-rich smectite precipitated near the mixing front and is likely to form an impermeable barrier between regions with acidic and neutral fluids.

Todaka, Norifumi; Akasaka, Chitosi; Xu, Tianfu; Pruess, Karsten

2003-04-09T23:59:59.000Z

375

Original article: An efficient, simplified multiple-coupled circuit model of the induction motor aimed to simulate different types of stator faults  

Science Conference Proceedings (OSTI)

This paper proposes an original simplified model aimed to simulate, an easy way, inter turns short circuit fault, phase to phase fault and phase to ground fault. In this model, the stator is considered as six magnetically coupled windings and the rotor ... Keywords: Fault diagnosis, Inter turns short circuit fault, Phase to ground fault, Phase to phase fault, Symmetrical components

M. Bouzid, G. Champenois

2013-04-01T23:59:59.000Z

376

Magnesium Workshop Madrid 2013 - TMS  

Science Conference Proceedings (OSTI)

Additional tickets (____ x$20). Guided Visit to Toledo and Conference Banquet. ? Plan to attend. ? Do not plan to attend. ? Additional tickets (_____ x $85).

377

Magnesium Workshop Madrid 2013: Registration  

Science Conference Proceedings (OSTI)

TMS reserves the right to any audio and video reproduction of all presentations at every TMS-sponsored meeting. Recording of sessions (audio, video,...

378

Magnesium Workshop Madrid 2013: Housing  

Science Conference Proceedings (OSTI)

VOLUNTEER TOOLS, Expand VOLUNTEER TOOLS .... The weather in May is delightful; warm and dry with average temperatures around 22C. Obtain a Travel ...

379

Decreasing Slip Rates From12.8 Ma to Present on the Solitario Canyon Fault at Yucca Mountain, Nevada  

DOE Green Energy (OSTI)

The Solitario Canyon fault, which bounds the west side of Yucca Mountain, Nevada, is the closest fault with Quaternary offset adjacent to the proposed spent nuclear fuel and high-level radioactive waste repository. Dip-slip offset between 12.8 and 10.7 Ma is determined from lithostratigraphic displacement in boreholes USW H-3 and USW WT-7, drilled in the footwall and hanging wall, respectively. The base of the 12.8-Ma Topopah Spring Tuff is interpreted to have 463.3 m of separation across the fault, an average dip slip rate of 0.036 mm/yr. Previous researchers identified a geothermal system active from 11.5 to 10.0 Ma with peak activity at 10.7 Ma that resulted in pervasive alteration of vitric rock to zeolitic minerals where the rocks were in the ground-water saturated zone. The contact between vitric (V) and pervasively zeolitic (Z) rocks cuts across the lithostratigraphic section and offset of this V-Z boundary can be used to measure slip rates between 12.8 and 10.7 Ma. In H-3, the V-Z boundary is 138.4 m below the base of the vitric, densely welded subzone of the Topopah Spring Tuff (Tptpv3). In WT-7, although the V-Z boundary is identified at the base of the Tptpv3, borehole video, cuttings, and geophysical log data indicate the Tptpv3 has well-developed zeolitic alteration along fractures, and this implies 19.5 m of the total thickness of Tptpv3 (and probably additional overlying crystallized rocks) also were in the saturated zone by 10.7 Ma. The V-Z relations across the Solitario Canyon fault in H-3 and WT-7 indicate a minimum of 157.9 m of separation before 10.7 Ma, which is 34.1 percent of the total slip of the Topopah Spring Tuff, and a minimum dip slip rate of 0.075 mm/yr from 12.8 to 10.7 Ma. These data are consistent with the broader structural history of the area near Yucca Mountain. Previous workers used angular unconformities, tilting of structural blocks, and paleomagnetic data to constrain the main period of extensional faulting between 12.7 and 8.5 Ma. Paleoseismic studies in Quaternary deposits documented slip rates on the Solitario Canyon fault from 0.01 to 0.02 mm/yr since 0.077 and 0.20 Ma. The decrease of extensional activity slip rates data on the Solitario Canyon fault provide evidence of decreasing tectonic activity from the middle Miocene to present.

D. Buesch

2006-07-11T23:59:59.000Z

380

Climate Zone 3B | Open Energy Information  

Open Energy Info (EERE)

Climate Zone 3B Climate Zone 3B Jump to: navigation, search A type of climate defined in the ASHRAE 169-2006 standard consisting of Climate Zone Number 3 and Climate Zone Subtype B. Climate Zone 3B is defined as Dry with IP Units 4500 < CDD50ºF ≤ 6300 and SI Units 2500 < CDD10ºC < 3500 . The following places are categorized as class 3B climate zones: Andrews County, Texas Baylor County, Texas Borden County, Texas Brewster County, Texas Butte County, California Callahan County, Texas Chaves County, New Mexico Childress County, Texas Clark County, Nevada Cochise County, Arizona Coke County, Texas Coleman County, Texas Collingsworth County, Texas Colusa County, California Concho County, Texas Contra Costa County, California Cottle County, Texas Crane County, Texas Crockett County, Texas

Note: This page contains sample records for the topic "madrid fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Climate Zone 5A | Open Energy Information  

Open Energy Info (EERE)

Zone 5A Zone 5A Jump to: navigation, search A type of climate defined in the ASHRAE 169-2006 standard consisting of Climate Zone Number 5 and Climate Zone Subtype A. Climate Zone 5A is defined as Cool- Humid with IP Units 5400 < HDD65ºF ≤ 7200 and SI Units 3000 < HDD18ºC ≤ 4000 . The following places are categorized as class 5A climate zones: Adair County, Iowa Adair County, Missouri Adams County, Illinois Adams County, Indiana Adams County, Iowa Adams County, Nebraska Adams County, Pennsylvania Albany County, New York Allegan County, Michigan Alleghany County, North Carolina Allegheny County, Pennsylvania Allen County, Indiana Allen County, Ohio Andrew County, Missouri Antelope County, Nebraska Appanoose County, Iowa Armstrong County, Pennsylvania Arthur County, Nebraska

382

Climate Zone 5B | Open Energy Information  

Open Energy Info (EERE)

Climate Zone 5B Climate Zone 5B Jump to: navigation, search A type of climate defined in the ASHRAE 169-2006 standard consisting of Climate Zone Number 5 and Climate Zone Subtype B. Climate Zone 5B is defined as Dry with IP Units 5400 < HDD65ºF ≤ 7200 and SI Units 3000 < HDD18ºC ≤ 4000 . The following places are categorized as class 5B climate zones: Ada County, Idaho Adams County, Colorado Adams County, Washington Apache County, Arizona Arapahoe County, Colorado Asotin County, Washington Baker County, Oregon Beaver County, Utah Benewah County, Idaho Bent County, Colorado Benton County, Washington Boulder County, Colorado Broomfield County, Colorado Canyon County, Idaho Carson City County, Nevada Cassia County, Idaho Catron County, New Mexico Chelan County, Washington Cheyenne County, Colorado

383

Climate Zone Number 1 | Open Energy Information  

Open Energy Info (EERE)

Climate Zone Number 1 Climate Zone Number 1 Jump to: navigation, search A type of climate defined in the ASHRAE 169-2006 standard. Climate Zone Number 1 is defined as Very Hot - Humid(1A) with IP Units 9000 < CDD50ºF and SI Units 5000 < CDD10ºC Dry(1B) with IP Units 9000 < CDD50ºF and SI Units 5000 < CDD10ºC . The following places are categorized as class 1 climate zones: Broward County, Florida Hawaii County, Hawaii Honolulu County, Hawaii Kalawao County, Hawaii Kauai County, Hawaii Maui County, Hawaii Miami-Dade County, Florida Monroe County, Florida Retrieved from "http://en.openei.org/w/index.php?title=Climate_Zone_Number_1&oldid=21604" Category: ASHRAE Climate Zones What links here Related changes Special pages Printable version Permanent link Browse properties

384

Climate Zone 2A | Open Energy Information  

Open Energy Info (EERE)

Climate Zone 2A Climate Zone 2A Jump to: navigation, search A type of climate defined in the ASHRAE 169-2006 standard consisting of Climate Zone Number 2 and Climate Zone Subtype A. Climate Zone 2A is defined as Hot - Humid with IP Units 6300 < CDD50ºF ≤ 9000 and SI Units 3500 < CDD10ºC ≤ 5000 . The following places are categorized as class 2A climate zones: Acadia Parish, Louisiana Alachua County, Florida Allen Parish, Louisiana Anderson County, Texas Angelina County, Texas Appling County, Georgia Aransas County, Texas Ascension Parish, Louisiana Assumption Parish, Louisiana Atascosa County, Texas Atkinson County, Georgia Austin County, Texas Avoyelles Parish, Louisiana Bacon County, Georgia Baker County, Florida Baker County, Georgia Baldwin County, Alabama Bastrop County, Texas

385

Enterprise Zone Program (Texas) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Enterprise Zone Program (Texas) Enterprise Zone Program (Texas) Enterprise Zone Program (Texas) < Back Eligibility Commercial Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Texas Program Type Corporate Tax Incentive Enterprise Zone Provider Texas Wide Open for Business The Enterprise Zone Program eligible projects to apply for state sales and use tax refunds on purchases of all taxable items purchased for use at qualified business sites related to the project or activity. The level and amount of refund is related to the capital investment and jobs created at the qualified business site. In addition, local communities must offer incentives to participants under the enterprise zone program, such as tax

386

Coastal Zone Management Act | Open Energy Information  

Open Energy Info (EERE)

Zone Management Act Zone Management Act Jump to: navigation, search Statute Name Coastal Zone Management Act Year 1972 Url [[File:|160px|link=]] Description The Coastal Zone Management Act of 1972 (CZMA; Pub.L. 92-583, 86 Stat. 1280, enacted October 27, 1972, 16 U.S.C. §§ 1451-1464, Chapter 33) is an Act of Congress passed in 1972 to encourage coastal states to develop and implement coastal zone management plans (CZMPs). This act was established as a United States National policy to preserve, protect, develop, and where possible, restore or enhance, the resources of the Nation's coastal zone for this and succeeding generations. References Wikipedia[1] National Oceanic and Atmospheric Administration[2] The U.S. Congress recognized the importance of meeting the challenge of

387

Fault Oblivious eXascale Whitepaper  

Science Conference Proceedings (OSTI)

In this paper we present a software system which supports dynamic, irregular, adaptive applications. Data objects are created and structured in a hierarchical manner, with replication as needed to provide a high degree of redundancy. The data objects can contain data, code, tasks (work descriptors with references to data, code, and other tasks) and higher level structures such as work queues. The higher level structures benefit from the properties of the data objects: redundant storage to support resiliency in the face of hardware failure; hierarchical structure to optimize use of the HPC system; and a presence of object names, available in the per-user file system name space, which allows any application, not just specially written HPC applications, to make use of the data even while it is on the HPC system. Our use of hierarchy will make the runtime scalable to very large systems. Our use of redundancy will allow programs to be written in a fault-oblivious manner, eliminating the need for system-level checkpointing. Putting data object names into the file system name space allows for interactive use of the system by users. With this approach, we will be able to finally leave the batch era behind, a half-century after the invention of time sharing. We will be able to stop bounding program through- put by the checkpoint interval. Application data will be accessible at any time, not hidden behind opaque 128-bit pointers or MPI ranks, but given a name that is visible everywhere. Programmers can stop laying out data, and thinking about where the data is, and the code is, and the nodes are, and stick with the problem of what the application is supposed to be doing. This work, if it succeeds, will enable scientific computing to scale to the next generation of machines.

Minnich, Ronald G.; Janssen, Curtis L.; Krishnamoorthy, Sriram; Marquez, Andres; Gokhale, Maya; Sadayappan, Ponnuswamy; Van Hensbergen, Eric; McKie, Jim; Appavoo, Jonathan

2011-06-01T23:59:59.000Z

388

Streamside Management Zones (Montana) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Streamside Management Zones (Montana) Streamside Management Zones (Montana) Streamside Management Zones (Montana) < Back Eligibility Utility Fed. Government Commercial Agricultural Investor-Owned Utility State/Provincial Govt Industrial Construction Municipal/Public Utility Local Government Residential Installer/Contractor Rural Electric Cooperative Tribal Government Low-Income Residential Schools Retail Supplier Institutional Multi-Family Residential Systems Integrator Fuel Distributor Nonprofit General Public/Consumer Transportation Savings Category Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Montana Program Type Environmental Regulations Provider Montana Department of Natural Resources and Conservation This chapter sets streamside management zones as encompassing a strip at

389

Enterprise Zone Incentives (Florida) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Incentives (Florida) Incentives (Florida) Enterprise Zone Incentives (Florida) < Back Eligibility Agricultural Commercial Fuel Distributor Industrial Retail Supplier Systems Integrator Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Florida Program Type Enterprise Zone Provider Florida Department of Economic Opportunity Enterprise Zone Incentives encourage business growth within certain geographic areas targeted for economic revitalization. Businesses which create jobs within a designated zone are eligible for several tax incentives, including sales and use tax credit, tax refunds for machinery or equipment, sales tax refund for building materials, and a sales tax exemption for electrical energy

390

Variability management of safety and reliability models: an intermediate model towards systematic reuse of component fault trees  

Science Conference Proceedings (OSTI)

Reuse of fault trees helps in reducing costs and effort when conducting Fault Tree Analyses (FTAs) for a set of similar systems. Some approaches have been proposed for the systematic reuse of fault trees along with the development of a product line of ... Keywords: component fault trees, fault tree analysis, product line engineering, safety and reliability, variability management

Carolina Gmez; Peter Liggesmeyer; Ariane Sutor

2010-09-01T23:59:59.000Z

391

Study of Reservoir Heterogencities and Structural Features Affecting Production in the Shallow Oil Zone, Eastern Elk Hills Area, California  

Science Conference Proceedings (OSTI)

Late Neogene (Plio-Pleistocene) shallow marine strata of the western Bakersfield Arch and Elk Hills produce hydrocarbons from several different reservoirs. This project focuses on the shallow marine deposits of the Gusher and Calitroleum reservoirs in the Lower Shallow Oil Zone (LSOZ). In the eastern part of the study area on the Bakersfield Arch at North and South Coles Levee field and in two wells in easternmost Elk Hills, the LSOZ reservoirs produce dry (predominantly methane) gas. In structurally higher locations in western Elk Hills, the LSOZ produces oil and associated gas. Gas analyses show that gas from the eastern LSOZ is bacterial and formed in place in the reservoirs, whereas gas associated with oil in the western part of the study area is thermogenic and migrated into the sands from deeper in the basin. Regional mapping shows that the gas-bearing LSOZ sands in the Coles Levee and easternmost Elk Hills area are sourced from the Sierra Nevada to the east whereas the oil-bearing sands in western Elk Hills appear to be sourced from the west. The eastern Elk Hills area occupied the basin depocenter, farthest from either source area. As a result, it collected mainly low-permeability offshore shale deposits. This sand-poor depocenter provides an effective barrier to the updip migration of gases from east to west. The role of small, listric normal faults as migration barriers is more ambiguous. Because our gas analyses show that the gas in the eastern LSOZ reservoirs is bacterial, it likely formed in-place near the reservoirs and did not have to migrate far. Therefore, the gas could have been generated after faulting and accumulated within the fault blocks as localized pools. However, bacterial gas is present in both the eastern AND western parts of Elk Hills in the Dry Gas Zone (DGZ) near the top of the stratigraphic section even though the measured fault displacement is greatest in this zone. Bacterial gas is not present in the west in the deeper LSOZ which has less measured fault displacement. The main difference between the DGZ and the LSOZ appears to be the presence of a sandpoor area in the LSOZ in eastern Elk Hills. The lack of permeable migration pathways in this area would not allow eastern bacterial gas to migrate farther updip into western Elk Hills. A similar sand-poor area does not appear to exist in the DGZ but future research may be necessary to verify this.

Janice Gillespie

2004-11-01T23:59:59.000Z

392

New approach to the fault location problem using synchronized sampling  

E-Print Network (OSTI)

This thesis presents a new approach to solving the problem of fault location on a transmission line using synchronized data from both ends of the line. The synchronized phase voltage and current samples taken during the fault transient are used to calculate the location of the fault. Time domain models of lines are used as a basis for derivation of two different algorithms. One algorithm is developed using the RL line model and the other one is developed using the traveling wave based line model. The main idea of the fault location concept is based on the general characteristics of any transmission line. At any location along the unfaulted line, the instantaneous values of voltage and current signals are related to the instantaneous values of the corresponding values of voltage and current signals at both ends of the line, line parameters, and distance between that particular location and each of the line ends. This enables the derivation of the generic fault location equation of the following form: [ ] where Lv is the linear operator, VA, t'A, VB, z'B are vectors of voltage and current samples at line ends, d is the length of the line, and x is the unknown distance to the fault point. For a particular transmission line, the generic equation has a unique form that determines the way it is solved. In any case, the Minimum Square Error Estimation Method is used since an overspecified system of linear equations needs to be solved. The performance evaluation of both algorithms was done using the Electromagnetic Transient Program (EMTP) generated data [1]. Obtained results indicate the high accuracy of the approach and its robustness regarding various fault conditions. The following are the conclusions based on the results presented in this thesis: The error of the approach is rather small and almost invariant to the various fault conditions and, hence, the technique provides a robust solution to the fault location problem. The new approach has high accuracy while the computational burden is still kept relatively low. The synchronized sampling technique required for this approach is emerging as a reliable and cost effective practice.

Mrkic, Jasna

1994-01-01T23:59:59.000Z

393

Accident Fault Trees for Defense Waste Processing Facility  

Science Conference Proceedings (OSTI)

The purpose of this report is to document fault tree analyses which have been completed for the Defense Waste Processing Facility (DWPF) safety analysis. Logic models for equipment failures and human error combinations that could lead to flammable gas explosions in various process tanks, or failure of critical support systems were developed for internal initiating events and for earthquakes. These fault trees provide frequency estimates for support systems failures and accidents that could lead to radioactive and hazardous chemical releases both on-site and off-site. Top event frequency results from these fault trees will be used in further APET analyses to calculate accident risk associated with DWPF facility operations. This report lists and explains important underlying assumptions, provides references for failure data sources, and briefly describes the fault tree method used. Specific commitments from DWPF to provide new procedural/administrative controls or system design changes are listed in the ''Facility Commitments'' section. The purpose of the ''Assumptions'' section is to clarify the basis for fault tree modeling, and is not necessarily a list of items required to be protected by Technical Safety Requirements (TSRs).

Sarrack, A.G.

1999-06-22T23:59:59.000Z

394

Identifying Efficiency Degrading Faults in Split Air Conditioning Systems  

E-Print Network (OSTI)

Studies estimate that as much as 50% of packaged air conditioning systems operate in faulty conditions that degrade system efficiency. Common faults include: under- and over-charged systems (too much or too little refrigerant), faulty expansions valves (stuck valves, valve hunting, poorly tuned valve controllers), and fouled evaporators and condensers. Furthermore, air conditioning systems can often be adjusted to improve efficiency while continuing to meet cooling loads (adjusting system pressures, decreasing superheat setpoints). This study presents the design of a low cost device that can non-invasively measure system operating conditions, diagnose faults, estimate potential energy savings, and provide recommendations on how the system should be adjusted or repaired. Using eight external temperature measurements, the device potentially can detect and diagnose up to ten faults commonly found in HVAC systems. Steady state temperatures are compared to threshold values obtained from literature and HVAC manufacturers to detect and determine the severity of faults and subsequent reductions in coefficient of performance. Preliminary tests reveal the potential for the device to detect and diagnose common efficiency-degrading faults in HVAC systems.

Terrill, T. J.; Brown, M. L.; Cheyne, R. W. Jr.; Cousins, A. J.; Daniels, B. P.; Erb, K. L.; Garcia, P. A.; Leutermann, M. J.; Nel, A. J.; Robert, C. L.; Widger, S. B.; Williams, A. G.; Rasmussen, B. P.

2013-01-01T23:59:59.000Z

395

Low cost fault detection system for railcars and tracks  

E-Print Network (OSTI)

A "low cost fault detection system" that identifies wheel flats and defective tracks is explored here. This is achieved with the conjunction of sensors, microcontrollers and Radio Frequency (RF) transceivers. The objective of the proposed research is to identify faults plaguing railcars and to be able to clearly distinguish the faults of a railcar from the inherent faults in the track. The focus of the research though, is mainly to identify wheel flats and defective tracks. The thesis has been written with the premise that the results from the simulation software GENSYS are close to the real time data that would have been obtained from an actual railcar. Based on the results of GENSYS, a suitable algorithm is written that helps segregate a fault in a railcar from a defect in a track. The above code is implemented using hardware including microcontrollers, accelerometers, RF transceivers and a real time monitor. An enclosure houses the system completely, so that it is ready for application in a real environment. This also involves selection of suitable hardware so that there is a uniform source of power supply that reduces the cost and assists in building a robust system.

Vengalathur, Sriram T.

2003-08-01T23:59:59.000Z

396

New fault locating system for air-insulated substations using optical current detector  

Science Conference Proceedings (OSTI)

This paper deals with a newly developed fault locating system. This fault locating system helps to shorten the time required for restoration of service after the occurrence of a busbar fault in an air-insulated distribution substation. Recent optical and electronic technologies allow highly accurate and compact fault locating system, which consists of optical current detectors using Faraday effect and a fault locating processor employing digital data processing technique. The fault location is made by discriminating the direction of zero-sequence currents. Through various tests and field operations it has been confirmed that the system has sufficient performance for practical application.

Yoshida, Y.; Kawazoe, S. (Kansai Electric Power Co., Inc., Osaka (Japan)); Ibuki, K.; Yamada, K.; Ochi, N. (Mitsubishi Electric Corp., Amagasaki, Hyogo (Japan). Itami Works)

1992-10-01T23:59:59.000Z

397

Regional assessment of geothermal potential along the Balcones and Luling-Mexia-Talco Fault Zones, Central Texas. Final report  

DOE Green Energy (OSTI)

A region-wide inventory and assessment of aquifers known to yield warm water (greater than 90/sup 0/F, 32/sup 0/C) is presented. This study was conducted to ascertain the potential for obtaining geothermal energy for space heating and water heating. The aquifers investigated include the Hosston/Trinity Sands, the Hensel Sand, the Paluxy Sand, the Edwards Limestone, and the Woodbine Sand. Each aquifer was examined in terms of its stratigraphic and structural framework and its hydrogeological properties. (MHR)

Woodruff, C.M. Jr.; McBride, M.W.

1979-05-01T23:59:59.000Z

398

Bull. Soc. gol. Fr., 2008, no The Rio Bravo fault, a major late Oligocene left-lateral shear zone  

E-Print Network (OSTI)

splays classified by age (courtesy of PEMEX modified). Thin lines is gravimetric contouring of figure 7 des reservoirs pétroliers classés par âge (courtoisie de PEMEX, figure modifiée). Le contourage en base provided mainly by PEMEX. We have used both 2D and 3D seismic interpretations to built

Husson, Laurent

399

3D Temperature distribution and numerical modeling of heat transfers in an active fault zone: Eugene Island 330, Offshore Louisiana.  

E-Print Network (OSTI)

temperature distributions by using some of the most commonly recorded data in modern oil field exploration sensitive to the movement of strong seismic events such as oil/water and gas/oil contacts on the scale for the dynamics of active oil fields. Here, Plio- Pleistocene sandstone reservoirs are supplied with mature

Guerin, Gilles

400

A Prognostic Relationship for Entrainment Zone Thickness  

Science Conference Proceedings (OSTI)

The thickness of the entrainment zone at the top of the atmospheric mixed layer is analyzed using measurements made with a ground-based lidar during the BLX83 and CIRCE field programs. When the entrainment-zone depth normalized by mixed-layer ...

Eric Nelson; Roland Stull; Edwin Eloranta

1989-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "madrid fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Geologic Assessment of the Damage Zone from the Second Test at Source Physics Experiment-Nevada (SPE-N)  

Science Conference Proceedings (OSTI)

The National Center for Nuclear Security (NCNS), established by the U.S. Department of Energy, National Nuclear Security Administration, is conducting a series of explosive tests at the Nevada National Security Site (NNSS; formerly the Nevada Test Site) that are designed to increase the understanding of certain basic physical phenomena associated with underground explosions. These tests will aid in developing technologies that might be used to detect underground nuclear explosions in support of verification activities for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The initial NCNS project is a series of explosive tests, known collectively as the Source Physics Experiment at the NNSS (SPE-N), being conducted in granitic rocks at the Climax stock in northern Yucca Flat. The SPE-N test series is designed to study the generation and propagation of seismic waves. The data will be used to improve the predictive capability of calculational models for detecting and characterizing underground explosions. The first SPE-N test (SPE-N-1) was a calibration shot conducted in May 2011, using 100 kilograms (kg) of explosives at the depth of 54.9 meters (m) (180 feet [ft]) in the U-15n source hole. SPE-N-2 was conducted in October 2011, using 1,000 kg of explosives at the depth of 45.7 m (150 ft) in the same source hole. Following the SPE-N-2 test, the core hole U-15n#10 was drilled at an angle from the surface to intercept the SPE-N-2 shot point location to obtain information necessary to characterize the damage zone. The desire was to determine the position of the damage zone near the shot point, at least on the northeast side, where the core hole penetrated it. The three-dimensional shape and symmetry of the damage zone are unknown at this time. Rather than spherical in shape, the dimensions of the damage zone could be influenced by the natural fracture sets in the vicinity. Geologic characterization of the borehole included geophysical logging, a directional survey, and geologic description of the core to document visual evidence of damage. Selected core samples were provided to Sandia National Laboratories (SNL) for laboratory tests (to be reported by SNL). A significant natural fault zone was encountered in the U-15n#10 angle core hole between the drilled depths of 149 and 155 ft (straight-line distance or range station [RS] from the shot point of 7.5 to 5.7 m). However, several of the fractures observed in the U-15n#10 hole are interpreted as having been caused by the explosion. These fractures are characterized by a fresh, mechanically broken look, with uncoated and very irregular surfaces. They tend to terminate against natural fractures and have orientations that differ from the previously defined natural fracture sets. The most distant fracture from the shot point that could be interpreted as having been caused by the explosion was seen at approximately RS 10.0 m. No other possibly explosion-induced fractures are apparent above the fault, but are common starting at RS 5.4 m, which is below the fault. It is unknown how the fault zone might have affected the propagation of seismic waves or how the materials in the fault zone (altered granite, breccia, gouge) were affected by the explosion. From RS 3.3 m to the end of the recovered core at RS 1.6 m, some of the core samples are softer and lighter in color, but do not appear to be weathered. It is thought this could be indicative of the presence of distributed microfracturing.

,

2012-09-18T23:59:59.000Z

402

Detection of Rooftop Cooling Unit Faults Based on Electrical Measurements  

Science Conference Proceedings (OSTI)

Non-intrusive load monitoring (NILM) is accomplished by sampling voltage and current at high rates and reducing the resulting start transients or harmonic contents to concise ''signatures''. Changes in these signatures can be used to detect, and in many cases directly diagnose, equipment and component faults associated with roof-top cooling units. Use of the NILM for fault detection and diagnosis (FDD) is important because (1) it complements other FDD schemes that are based on thermo-fluid sensors and analyses and (2) it is minimally intrusive (one measuring point in the relatively protected confines of the control panel) and therefore inherently reliable. This paper describes changes in the power signatures of fans and compressors that were found, experimentally and theoretically, to be useful for fault detection.

Armstrong, Peter R.; Laughman, C R.; Leeb, S B.; Norford, L K.

2006-01-31T23:59:59.000Z

403

Adiabatic Quantum Programming: Minor Embedding With Hard Faults  

SciTech Connect

Adiabatic quantum programming defines the time-dependent mapping of a quantum algorithm into the hardware or logical fabric. An essential programming step is the embedding of problem-specific information into the logical fabric to define the quantum computational transformation. We present algorithms for embedding arbitrary instances of the adiabatic quantum optimization algorithm into a square lattice of specialized unit cells. Our methods are shown to be extensible in fabric growth, linear in time, and quadratic in logical footprint. In addition, we provide methods for accommodating hard faults in the logical fabric without invoking approximations to the original problem. These hard fault-tolerant embedding algorithms are expected to prove useful for benchmarking the adiabatic quantum optimization algorithm on existing quantum logical hardware. We illustrate this versatility through numerical studies of embeddabilty versus hard fault rates in square lattices of complete bipartite unit cells.

Klymko, Christine F [ORNL] [ORNL; Sullivan, Blair D [ORNL] [ORNL; Humble, Travis S [ORNL] [ORNL

2013-01-01T23:59:59.000Z

404

Optimizing automated gas turbine fault detection using statistical pattern recognition  

SciTech Connect

A method enabling the automated diagnosis of Gas Turbine Compressor blade faults, based on the principles of statistical pattern recognition is initially presented. The decision making is based on the derivation of spectral patterns from dynamic measurements data and then the calculation of discriminants with respect to reference spectral patterns of the faults while it takes into account their statistical properties. A method of optimizing the selection of discriminants using dynamic measurements data is also presented. A few scalar discriminants are derived, in such a way that the maximum available discrimination potential is exploited. In this way the success rate of automated decision making is further improved, while the need for intuitive discriminant selection is eliminated. The effectiveness of the proposed methods is demonstrated by application to data coming from an Industrial Gas Turbine while extension to other aspects of Fault Diagnosis is discussed. 9 refs.

Loukis, E.; Mathioudakis, K.; Papailiou, K. (Athens National Technical Univ. (Greece))

1992-01-01T23:59:59.000Z

405

Optimizing automated gas turbine fault detection using statistical pattern recognition  

SciTech Connect

A method enabling the automated diagnosis of gas turbine compressor blade faults, based on the principles of statistical pattern recognition, is initially presented. The decision making is based on the derivation of spectral patterns from dynamic measurement data and then the calculation of discriminants with respect to reference spectral patterns of the faults while it takes into account their statistical properties. A method of optimizing the selection of discriminants using dynamic measurement data is also presented. A few scalar discriminants are derived, in such a way that the maximum available discrimination potential is exploited. In this way the success rate of automated decision making is further improved, while the need for intuitive discriminant selection is eliminated. The effectiveness of the proposed methods is demonstrated by application to data coming from an industrial gas turbine while extension to other aspects of fault diagnosis is discussed.

Loukis, E.; Mathioudakis, K.; Papailiou, K. (National Technical Univ. of Athens (Greece). Lab. of Thermal Turbomachines)

1994-01-01T23:59:59.000Z

406

Climate Zone 7B | Open Energy Information  

Open Energy Info (EERE)

B B Jump to: navigation, search A type of climate defined in the ASHRAE 169-2006 standard consisting of Climate Zone Number 7 and Climate Zone Subtype B. Climate Zone 7A is defined as Very Cold with IP Units 9000 < HDD65ºF ≤ 12600 and SI Units 5000 < HDD18ºC ≤ 7000 . The following places are categorized as class 7B climate zones: Clear Creek County, Colorado Grand County, Colorado Gunnison County, Colorado Hinsdale County, Colorado Jackson County, Colorado Lake County, Colorado Lincoln County, Wyoming Mineral County, Colorado Park County, Colorado Pitkin County, Colorado Rio Grande County, Colorado Routt County, Colorado San Juan County, Colorado Sublette County, Wyoming Summit County, Colorado Teton County, Wyoming Retrieved from "http://en.openei.org/w/index.php?title=Climate_Zone_7B&oldid=2161

407

Applied Field Research Initiative Deep Vadose Zone  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Applied Field Research Initiative Applied Field Research Initiative Deep Vadose Zone Located on the Hanford Site in Richland, Washington, the Deep Vadose Zone Applied Field Research Initiative (DVZ AFRI) was established to protect water resources by addressing the challenge of preventing contamination in the deep vadose zone from reaching groundwater. Led by the Pacific Northwest National Laboratory, the Initiative is a collaborative effort that leverages Department of Energy (DOE) investments in basic science and applied research and the work of site contractors to address the complex deep vadose zone contamination challenges. Challenge Many vadose zone environments within the DOE complex consist of complex stratified layers of unconsolidated and water-unsaturated sediments that are, in many places, con-

408

Climate Zone 6B | Open Energy Information  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon » Climate Zone 6B Jump to: navigation, search A type of climate defined in the ASHRAE 169-2006 standard consisting of Climate Zone Number 6 and Climate Zone Subtype B. Climate Zone 6B is defined as Dry with IP Units 7200 < HDD65ºF ≤ 9000 and SI Units 4000 < HDD18ºC ≤ 5000 . The following places are categorized as class 6B climate zones: Adams County, Idaho Alamosa County, Colorado Albany County, Wyoming Alpine County, California Archuleta County, Colorado Bannock County, Idaho Bear Lake County, Idaho Beaverhead County, Montana Big Horn County, Montana Big Horn County, Wyoming

409

Climate Zone 4C | Open Energy Information  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon » Climate Zone 4C Jump to: navigation, search A type of climate defined in the ASHRAE 169-2006 standard consisting of Climate Zone Number 4 and Climate Zone Subtype C. Climate Zone 4C is defined as Mixed - Marine with IP Units 3600 < HDD65ºF ≤ 5400 and SI Units 2000 < HDD18ºC ≤ 3000 . The following places are categorized as class 4C climate zones: Benton County, Oregon Clackamas County, Oregon Clallam County, Washington Clark County, Washington Clatsop County, Oregon Columbia County, Oregon Coos County, Oregon Cowlitz County, Washington Curry County, Oregon Douglas County, Oregon

410

New Limits on Fault-Tolerant Quantum Computation  

E-Print Network (OSTI)

We show that quantum circuits cannot be made fault-tolerant against a depolarizing noise level of approximately 45%, thereby improving on a previous bound of 50% (due to Razborov). Our precise quantum circuit model enables perfect gates from the Clifford group (CNOT, Hadamard, S, X, Y, Z) and arbitrary additional one-qubit gates that are subject to that much depolarizing noise. We prove that this set of gates cannot be universal for arbitrary (even classical) computation, from which the upper bound on the noise threshold for fault-tolerant quantum computation follows.

Harry Buhrman; Richard Cleve; Monique Laurent; Noah Linden; Alexander Schrijver; Falk Unger

2006-04-19T23:59:59.000Z

411

Fault detection of multivariable system using its directional properties  

E-Print Network (OSTI)

A novel algorithm for making the combination of outputs in the output zero direction of the plant always equal to zero was formulated. Using this algorithm and the result of MacFarlane and Karcanias, a fault detection scheme was proposed which utilizes the directional property of the multivariable linear system. The fault detection scheme is applicable to linear multivariable systems. Results were obtained for both continuous and discrete linear multivariable systems. A quadruple tank system was used to illustrate the results. The results were further verified by the steady state analysis of the plant.

Pandey, Amit Nath

2004-12-01T23:59:59.000Z

412

The dynamics of oceanic transform faults : constraints from geophysical, geochemical, and geodynamical modeling  

E-Print Network (OSTI)

Segmentation and crustal accretion at oceanic transform fault systems are investigated through a combination of geophysical data analysis and geodynamical and geochemical modeling. Chapter 1 examines the effect of fault ...

Gregg, Patricia Michelle Marie

2008-01-01T23:59:59.000Z

413

Sherlocka system for diagnosing power distribution ring network faults  

Science Conference Proceedings (OSTI)

This paper reports the development of a software system, SHERLOCK, for fault diagnosis in power distribution ring networks. The system consists of a fault diagnosis subsystem implemented using Prolog and a user interface subsystem developed in the SmallTalk ...

Kit Po Wong; Chi Ping Tsang; Wan Yee Chan

1988-06-01T23:59:59.000Z

414

Model Acceptability Measure for the Identification of Failures in Qualitative Fault Monitoring Systems  

E-Print Network (OSTI)

This paper deals with two of the main tasks of Fault Monitoring Systems (FMS): fault detection and fault identification. During fault detection, the FMS should recognize that the plant behavior is abnormal, and therefore, that the plant is not working properly. During fault identification, the FMS should conclude which type of failure has occurred. The first goal of this work is to consolidate a new fault detection technique, called enveloping, that was developed in the context of the Fuzzy Inductive Reasoning Fault Monitoring System (FIRFMS). The second and primary goal of this paper is to introduce the model acceptability measure as a tool to enhance and make more robust the fault identification process in the context of FIRFMS. The enveloping technique and the model acceptability measure are applied to an electric circuit model previously used for such purpose in the literature. It is shown that the new methods outperform the ones previously advocated in FIRFMS for that purpose 1 ...

Antoni Escobet Angela; Angela Nebot; Francois E. Cellier

1999-01-01T23:59:59.000Z

415

FERRARI: A Flexible Software-Based Fault and Error Injection System  

Science Conference Proceedings (OSTI)

AbstractA major step toward the development offault-tolerant computer systems is the validation of the dependability properties of these systems. Fault/error injection has been recognized as a powerful approach to validate the fault tolerance mechanisms ...

Ghani A. Kanawati; Nasser A. Kanawati; Jacob A. Abraham

1995-02-01T23:59:59.000Z

416

Slip on ridge transform faults : insights from earthquakes and laboratory experiments  

E-Print Network (OSTI)

The relatively simple tectonic environment of mid-ocean ridge transform fault (RTF) seismicity provides a unique opportunity for investigation of earthquake and faulting processes. We develop a scaling model that is complete ...

Boettcher, Margaret S

2005-01-01T23:59:59.000Z

417

Interseismic strain accumulation and the earthquake potential on the southern San Andreas fault system  

E-Print Network (OSTI)

lat- ter would imply subsidence to the east of the fault.indicate uplift, rather subsidence, to the east of the faultlikely involves ground subsidence to the west of the fault.

Fialko, Y

2006-01-01T23:59:59.000Z

418

Nail-it-down: nailing and fixing configuration faults in cloud environments  

Science Conference Proceedings (OSTI)

Faults due to configuration of resources account for majority of errors in distributed software systems. Yet, the problem of identifying faulty configuration remains at large. Current approaches for fault identification are focused on event correlation ...

Kalapriya Kannan; Anuradha Bhamidipaty

2013-05-01T23:59:59.000Z

419

Wetland Loss Is Not The Fault of Any One Company | America's ...  

U.S. Energy Information Administration (EIA)

Wetland Loss Is Not The Fault of Any One Company. By: Berwick Duvall II, Houma Courrier | 9.28.2007 September 28, 2007 Wetlands loss is not the fault ...

420

A COTS Wrapping Toolkit for Fault Tolerant Applications under Windows NT  

Science Conference Proceedings (OSTI)

This paper presents a software toolkit that allows enhancing the fault tolerant characteristics of a user application running under a Windows NT platform through sets of interchangeable and customizable Fault Tolerant Interposition Agents (FTI Agents). ...

Alfredo Benso; Silvia Chiusano; Paolo Prinetto

2000-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "madrid fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

A general method for calculating co-seismic gravity changes in complex fault systems  

Science Conference Proceedings (OSTI)

A general method for calculating the total, dilatational, and free-air gravity for fault systems with arbitrary geometry, slip motion, and number of fault segments is presented. The technique uses a Green's function approach for a fault buried within ... Keywords: 91.10.-v, 91.10.Kg, 91.10.Op, 91.30.Px, Alaska, California, Fault network, Time-variable gravity

T. J. Hayes; K. F. Tiampo; J. B. Rundle; J. Fernndez

2008-11-01T23:59:59.000Z

422

A model for the evaluation of fault tolerance in the FERMI system  

Science Conference Proceedings (OSTI)

Experiments of high energy physics planned at the Large Hadron Collider (LHC) at CERN (CH) require digital data acquisition systems with high throughput. Such systems need also be fault tolerant to the permanent and transient faults induced by radiation, ... Keywords: FERMI microsystem, Large Hadron Collider, VLSI, VLSI devices, data acquisition, digital data acquisition system, fault tolerance, fault tolerant computing, high energy physics, high energy physics instrumentation computing, model, nuclear electronics, radiation effects

A. Antola; L. Breveglieri

1995-11-01T23:59:59.000Z

423

Fault analysis of a semisubmersible's ballast control system  

SciTech Connect

This paper presents a practical ballast system for a twinhull design semisubmersible as an answer to the problems which could result from faults both interior and exterior to the system. The design presented is then examined through a fault analysis technique common to other industries and applicable to the life-sustaining ballast system. This examination confirms the design philosophy that a single fault or reasonable multiple faults should not lead to destabilization of the vessel.

Hock, C.J.; Balaban, E.G.

1984-05-01T23:59:59.000Z

424

Computer Aided Fault Tree Analysis System (CAFTA), Version 6.0 Demo  

Science Conference Proceedings (OSTI)

CAFTA is a computer software program used for developing reliability models of large complex systems, using fault tree and event tree methodology.DescriptionCAFTA is designed to meet the many needs of reliability analysts while performing fault tree/event tree analysis on a system or group of systems. It includes:Fault Tree Editor for building, updating and printing fault tree modelsEvent Tree Editor for building, ...

2013-02-18T23:59:59.000Z

425

Fault diagnosis of regenerative water heater based-on multi-class support vector machines  

Science Conference Proceedings (OSTI)

The main idea of multi-class support vector machines (SVMs) is described. a multi-class model for regenerative water heater fault diagnosis is presented combining the fuzzy logic and SVMs. The typical faults set of regenerative water heater is built ... Keywords: fault diagnosis, fuzzy rules, regenerative water heater, steam turbine, support vector machines

Lei Wang; Rui-Qing Zhang

2009-08-01T23:59:59.000Z

426

Ant Colony Clustering Procedure Used in Vibration Fault Diagnosis of Beam Pumping Unit  

Science Conference Proceedings (OSTI)

The study of vibration fault diagnosis of beam pumping unit is an important task to reasonable production, scientific management and improvement of the oil recovery. The vibration fault diagnosis is a good method with direct result. In view of measurement ... Keywords: ant colony algorithm, clustering procedure, beam pumping unit, fault, diagnosis

Wuguang Li; Shenglai Yang; Ranran Xu; Xiaoxu Sun; Xing Zhang

2011-10-01T23:59:59.000Z

427

Modeling and experimental validation of internal faults in salient pole synchronous machines including space harmonics  

Science Conference Proceedings (OSTI)

Considering the space harmonics caused by the faulted windings, a simulation model of internal faults in salient pole synchronous machines is proposed in this paper. The model is based on the winding function approach, which makes no assumption for sinusoidal ... Keywords: Internal faults, Space harmonics, Synchronous machines, Winding function

X. Tu; L. -A. Dessaint; M. El Kahel; A. Barry

2006-06-01T23:59:59.000Z

428

A CONTROLLER FOR HVAC SYSTEMS WITH FAULT DETECTION CAPABILITIES BASED ON SIMULATION MODELS  

E-Print Network (OSTI)

1 A CONTROLLER FOR HVAC SYSTEMS WITH FAULT DETECTION CAPABILITIES BASED ON SIMULATION MODELS T. I describes a control scheme with fault detection capabilities suitable for application to HVAC systems as a reference of correct operation. Faults that occur in the HVAC system under control cause the PI

429

Automatic fault diagnosis of internal combustion engine based on spectrogram and artificial neural network  

Science Conference Proceedings (OSTI)

This paper presents a signal analysis technique for internal combustion (IC) engine fault diagnosis based on the spectrogram and artificial neural network (ANN). Condition monitoring and fault diagnosis of IC engine through acoustic signal analysis is ... Keywords: acoustic analysis, fault diagnosis, internal combustion engine

Sandeep Kumar Yadav; Prem Kumar Kalra

2010-04-01T23:59:59.000Z

430

A systematic review of design diversity-based solutions for fault-tolerant SOAs  

Science Conference Proceedings (OSTI)

Context: Over recent years, software developers have been evaluating the benefits of both Service-Oriented Architecture and software fault tolerance techniques based on design diversity by creating fault-tolerant composite services that leverage ... Keywords: SLR, SOA, composite services, fault tolerance

Amanda S. Nascimento; Ceclia M. F. Rubira; Rachel Burrows; Fernando Castor

2013-04-01T23:59:59.000Z

431

A SVDD approach of fuzzy classification for analog circuit fault diagnosis with FWT as preprocessor  

Science Conference Proceedings (OSTI)

In this paper, a new approach of fault diagnosis in analog circuits, which employs the Fractional Wavelet Transform (FWT) to extract fault features and adopts a fuzzy multi-classifier based on the Support Vector Data Description (SVDD) to diagnose circuit ... Keywords: Analog circuit, Fault diagnosis, Feature extraction, Fractional wavelet transform, KFCM, SVDD

Hui Luo; Youren Wang, Jiang Cui

2011-08-01T23:59:59.000Z

432

Current Practice and a Direction Forward in Checkpoint/Restart Implementations for Fault Tolerance  

Science Conference Proceedings (OSTI)

Checkpoint/restart is a general idea for which particular implementations enable various functionalities in computer systems, including process migration, gang scheduling, hibernation, and fault tolerance. For fault tolerance, in current practice, implementations ... Keywords: Fault tolerance, checkpoint/restart, autonomic computing, Linux

Jose Carlos Sancho; Fabrizio Petrini; Kei Davis; Roberto Gioiosa; Song Jiang

2005-04-01T23:59:59.000Z

433

Assessment of power-frequency based algorithms for fault location in power grids  

Science Conference Proceedings (OSTI)

The increased accuracy of the faults' location is a very actual request of the power grids' operation and management, reason to develop new and as precise as possible techniques for the estimation of the short-circuits' location. The actual fault locating ... Keywords: ATP simulation, fault location, power grids, power-frequency based algorithms

Marcel Istrate

2010-10-01T23:59:59.000Z

434

High impedance fault location in transmission line using nonlinear frequency analysis  

Science Conference Proceedings (OSTI)

The detection and location of high impedance faults on power system has been one of the most difficult problems in power transmission and distribution systems. According to a very highly nonlinear behavior of high impedance faults, a methodology is presented ... Keywords: high impedance fault, nonlinear frequency analysis, power line carrier, transmission line

Min-You Chen; Jin-Qian Zhai; Zi-Qiang Lang; Ju-Cheng Liao; Zhao-Yong Fan

2010-09-01T23:59:59.000Z

435

Dynamic behaviour of a DFIG wind turbine subjected to power system faults  

E-Print Network (OSTI)

Dynamic behaviour of a DFIG wind turbine subjected to power system faults Gabriele Michalke+, Anca of the dynamic interaction between variable speed DFIG wind turbines and the power system subjected to disturbances, such as short circuit faults. Focus of the paper is the fault ride-through capability of DFIG

436

A general noise-reduction framework for fault localization of Java programs  

Science Conference Proceedings (OSTI)

Context: Existing fault-localization techniques combine various program features and similarity coefficients with the aim of precisely assessing the similarities among the dynamic spectra of these program features to predict the locations of faults. ... Keywords: Fault localization, Key block chain, Noise reduction, Program debugging

Jian Xu; Zhenyu Zhang; W. K. Chan; T. H. Tse; Shanping Li

2013-05-01T23:59:59.000Z

437

A Survey of NASA and Military Standards on Fault Tolerance and Reliability Applied to Robotics  

E-Print Network (OSTI)

. There are Hand­ books (Reliability of Electronic Equipment [7], MIL­HDBK­217F, Fault Tree Handbook [25], NUREG Com­ mission as NUREG­0492, the Fault Tree Hand­ book [25]. 2.2 Parts Specifications In addition and Mission Quality, Washington, DC, April 1991. [25] NUREG­0492. Fault Tree Handbook. Technical report

Rice University - Center for Cooperative Autonomous Robots for Hazardous Environments

438

Power Transformer Fault Diagnosis Based on Integrated of Rough Set Theory and Evidence Theory  

Science Conference Proceedings (OSTI)

When using chromatography data analysis in diagnosis of power transformer fault, fault information cannot be make full use, which can't effectively discover knowledge hidden in data. In this paper a method integreted of rough set theory and evidence ... Keywords: Rough Set, Evidence Theory, Power Transformer, Fault Diagnosis

Zhou Ai-Hua, Yao Yi, Song Hong, Zeng Xiao-Hui

2013-01-01T23:59:59.000Z

439

Fault Diagnosis of Regenerative Water Heater Based-On Multi-class Support Vector Machines  

Science Conference Proceedings (OSTI)

The main idea of multi-class support vector machines (SVMs) is described. a multi-class model for regenerative water heater fault diagnosis is presented combining the fuzzy logic and SVMs. The typical faults set of regenerative water heater is built ... Keywords: steam turbine, regenerative water heater, fuzzy rules, support vector machines, fault diagnosis

Lei Wang; Rui-qing Zhang

2009-08-01T23:59:59.000Z

440

Fault conditions classification of automotive generator using an adaptive neuro-fuzzy inference system  

Science Conference Proceedings (OSTI)

In this paper, an adaptive neuro-fuzzy inference system (ANFIS) was proposed for condition monitoring and fault diagnosis of an automotive generator. Conventional fault indication of an automotive generator generally uses an indicator to inform the driver ... Keywords: Adaptive neuro-fuzzy inference system, Automotive generator, Discrete wavelet transform, Fault diagnosis system

Jian-Da Wu; Jun-Ming Kuo

2010-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "madrid fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Solid-state fault current limiter for voltage sag mitigation and its parameters design  

Science Conference Proceedings (OSTI)

Due to the difficulty in electric distribution network reinforcement and the interconnection of more distributed generations, fault current level has become a serious problem in system operations. The utilization of solid-state fault current limiters ... Keywords: power quality, simulation, solid-state fault current limiter, voltage sag

B. Boribun; T. Kulworawanichpong

2010-07-01T23:59:59.000Z

442

Review article: Achieving maximum reliability in fault tolerant network design for variable networks  

Science Conference Proceedings (OSTI)

The objective of this paper is to present a novel method to achieve maximum reliability for fault tolerant optimal network design when network has variable size. Reliability calculation is most important and critical component when fault tolerant optimal ... Keywords: Fault tolerant optimal design, Fixed and varying link reliability, Maximizing reliability, Neural networks, Variable network size

B. Kaushik, N. Kaur, A. K. Kohli

2013-07-01T23:59:59.000Z

443

A systematic fuzzy rule based approach for fault classification in transmission lines  

Science Conference Proceedings (OSTI)

The paper presents a new approach for fault classification in transmission line using a systematic fuzzy rule based approach. Fault classification is one of the important requirements in distance relaying for identifying the accurate phases involved ... Keywords: DT-fuzzy rule base, Decision Tree, Distance relaying, Fault classification, Heuristic fuzzy system, S-transform, Wavelet transform

S. R. Samantaray

2013-02-01T23:59:59.000Z

444

YemanjaA Layered Fault Localization System for Multi-Domain Computing Utilities  

Science Conference Proceedings (OSTI)

Yemanja is a model-based event correlation engine for multi-layer fault diagnosis. It targets complex propagating fault scenarios, and can smoothly correlate low-level network events with high-level application performance alerts related to quality-of-service ... Keywords: Problem determination, event correlation, fault and performance management, service level agreements

K. Appleby; G. Goldszmidt; M. Steinder

2002-06-01T23:59:59.000Z

445

Bearing fault prognosis based on health state probability estimation  

Science Conference Proceedings (OSTI)

In condition-based maintenance (CBM), effective diagnostic and prognostic tools are essential for maintenance engineers to identify imminent fault and predict the remaining useful life before the components finally fail. This enables remedial actions ... Keywords: Degradation stage, High pressure LNG pump, Prognosis, Remaining useful life (RUL), Support Vector Machine (SVM)

Hack-Eun Kim; Andy C. C. Tan; Joseph Mathew; Byeong-Keun Choi

2012-04-01T23:59:59.000Z

446

Conditional edge-fault-tolerant Hamiltonicity of dual-cubes  

Science Conference Proceedings (OSTI)

The dual-cube is an interconnection network for linking a large number of nodes with a low node degree. It uses low-dimensional hypercubes as building blocks and keeps the main desired properties of the hypercube. A dual-cube DC(n) has n+1 links per ... Keywords: Conditional fault-tolerant, Dual-cubes, Hamiltonian cycle, Hypercube, Interconnection network

Jheng-Cheng Chen; Chang-Hsiung Tsai

2011-02-01T23:59:59.000Z

447

Modeling of switching operations using fault matrix method  

Science Conference Proceedings (OSTI)

Switching operations in energy supply networks are either modeled by adding or removing artificial nodes which results in state dependent grid topology or by setting the switch impedance to high or low value. This procedure is not very accurate and can ... Keywords: admittance matrix, fault matrix method, power system, switching operation, transmission lines

Martin Wolter; Bernd R. Oswald

2007-05-01T23:59:59.000Z

448

Hybrid simulation of large electrical networks with assymmetrical fault modelling  

Science Conference Proceedings (OSTI)

Owing to the increasing attention placed on dynamic security assessment in the light of recent blackouts, hybrid simulation, involving the interfacing of electromagnetic transients (EMT) simulators and transient stability (TS) simulators for the more ... Keywords: asymmetrical fault modelling, electromagnetic transients, hybrid simulation, interaction protocol, transient stability

H. T. Su; K. W. Chan; L. A. Snider

2008-03-01T23:59:59.000Z

449

Sensor Fault Detection in Power Plants Andrew Kusiak1  

E-Print Network (OSTI)

and Soroush 2003 . Any false reading could lead to di- sastrous outcomes. In a coal-fired power plant, faultySensor Fault Detection in Power Plants Andrew Kusiak1 and Zhe Song2 Abstract: This paper presents approach handles data from temporal processes by periodic updates of the knowledge base. An industrial

Kusiak, Andrew

450

A fault-tolerant strategy for virtualized HPC clusters  

Science Conference Proceedings (OSTI)

Virtualization is a common strategy for improving the utilization of existing computing resources, particularly within data centers. However, its use for high performance computing (HPC) applications is currently limited despite its potential for both ... Keywords: Benchmark, Checkpointing, Fault-tolerance, MPI, Virtualization

John Paul Walters; Vipin Chaudhary

2009-12-01T23:59:59.000Z

451

IEEE TRANSACTION ON COMPUTERS 1 Adaptive Fault Management of Parallel  

E-Print Network (OSTI)

of high performance computing (HPC) continues to grow, application fault resilience becomes crucial- tions, High performance computing, Large-scale systems. I. INTRODUCTION IN the field of high performance Performance Computing Zhiling Lan, Member, IEEE, and Yawei Li, Student Member, IEEE Abstract--As the scale

Lan, Zhiling

452

Fault tolerance using lower fidelity data in adaptive mesh applications  

Science Conference Proceedings (OSTI)

Many high performance scientific simulation codes use checkpointing for multiple reasons. In addition to having the flexibility to complete the simulation in multiple job submissions, it has also provided an adequate recovery mechanism up to the current ... Keywords: AMR, fault tolerance, flash

Anshu Dubey; Prateeti Mohapatra; Klaus Weide

2013-06-01T23:59:59.000Z

453

Dominant Feature Identification for Industrial Fault Detection and Isolation Applications  

Science Conference Proceedings (OSTI)

Fault Detection and Isolation (FDI) is crucial to reduce production costs and down-time in industrial machines. In this paper, we show how to find a reduced feature subset which is optimal in both estimation and clustering least square errors using a ... Keywords: Least Square Error (LSE), Neural Network (NN), Principal Component Analysis (PCA), Principal Feature Analysis (PFA), Singular Value Decomposition (SVD)

Jun-Hong Zhou; Chee Khiang Pang; Frank L. Lewis; Zhao-Wei Zhong

2011-08-01T23:59:59.000Z

454

Using Write Protected Data Structures To Improve Software Fault Tolerance  

E-Print Network (OSTI)

Using Write Protected Data Structures To Improve Software Fault Tolerance in Highly Available critical DBMS data structures against software errors. Guarding (write-protecting) DBMS data improves protection to new data structures very easy. To implement the expose segment update model in Sprite, we

California at Irvine, University of

455

RIS-M-2326 FAULT TREE AND CAUSE CONSEQUENCE ANALYSIS  

E-Print Network (OSTI)

and control, nuclear reactor safety systems and aircraft landing systems. For systems of failure in operations. For example a nuclear reactor shutdown system should fail at a rate which Abstract. A theory underlying application of automatic fault tree analysis to computer programs

456

Distributed Fault Diagnosis Using Bayesian Reasoning in MAGNETO  

Science Conference Proceedings (OSTI)

Many of the emerging telecom services make use of Outer Edge Networks, in particular Home Area Networks. The configuration and maintenance of such services may not be under full control of the telecom operator which still needs to guarantee the service ... Keywords: Bayesian inference, distributed fault diagnosis, outer edge, agents, self-learning

Pablo Arozarena; Raquel Toribio; Alvaro Carrera

2011-10-01T23:59:59.000Z

457

Differential energy based microgrid protection against fault conditions  

Science Conference Proceedings (OSTI)

A differential energy based fault protection in microgrid is presented in this paper. Initially the currents at the respective buses are retrieved and processed through a novel time-frequency transform known as S-transform to generate time-frequency ...

S. R. Samantaray; Geza Joos; I. Kamwa

2012-01-01T23:59:59.000Z

458

Embedded holonic fault diagnosis of complex transportation systems  

Science Conference Proceedings (OSTI)

The use of electronic equipment and embedded computing technologies in modern complex transportation systems continues to grow in a highly competitive market, in which product maintainability and availability is vital. These technological advances also ... Keywords: Cooperative fault diagnosis, Corrective maintenance, Embedded diagnosis, Holonic architecture, Model-based diagnosis, Railway transportation system

Antoine Le Mortellec; Joffrey Clarhaut; Yves Sallez; Thierry Berger; Damien Trentesaux

2013-01-01T23:59:59.000Z

459

Critique of Fault-Tolerant Quantum Information Processing  

E-Print Network (OSTI)

This is a chapter in a book \\emph{Quantum Error Correction} edited by D. A. Lidar and T. A. Brun, and published by Cambridge University Press (2013)\\\\ (http://www.cambridge.org/us/academic/subjects/physics/quantum-physics-quantum-information-and-quantum-computation/quantum-error-correction)\\\\ presenting the author's view on feasibility of fault-tolerant quantum information processing.

Robert Alicki

2013-10-31T23:59:59.000Z

460

Category:County Climate Zones | Open Energy Information  

Open Energy Info (EERE)

County Climate Zones County Climate Zones Jump to: navigation, search This category contains county climate zone information in the United States of America. Contents: Top - 0-9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Pages in category "County Climate Zones" The following 200 pages are in this category, out of 3,141 total. (previous 200) (next 200) A Abbeville County, South Carolina ASHRAE 169-2006 Climate Zone Acadia Parish, Louisiana ASHRAE 169-2006 Climate Zone Accomack County, Virginia ASHRAE 169-2006 Climate Zone Ada County, Idaho ASHRAE 169-2006 Climate Zone Adair County, Iowa ASHRAE 169-2006 Climate Zone Adair County, Kentucky ASHRAE 169-2006 Climate Zone Adair County, Missouri ASHRAE 169-2006 Climate Zone Adair County, Oklahoma ASHRAE 169-2006 Climate Zone

Note: This page contains sample records for the topic "madrid fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Observing Surf-Zone Dispersion with Drifters  

Science Conference Proceedings (OSTI)

Surf-zone dispersion is studied using drifter observations collected within about 200 m of the shoreline (at depths of less than about 5 m) on a beach with approximately alongshore uniform bathymetry and waves. There were about 70 individual ...

Matthew Spydell; Falk Feddersen; R. T. Guza; W. E. Schmidt

2007-12-01T23:59:59.000Z

462

Climate Zone Number 7 | Open Energy Information  

Open Energy Info (EERE)

Climate Zone Number 7 Climate Zone Number 7 Jump to: navigation, search A type of climate defined in the ASHRAE 169-2006 standard. Climate Zone Number 7 is defined as Very Cold with IP Units 9000 < HDD65ºF ≤ 12600 and SI Units 5000 < HDD18ºC ≤ 7000 . The following places are categorized as class 7 climate zones: Aitkin County, Minnesota Aleutians East Borough, Alaska Aleutians West Census Area, Alaska Anchorage Borough, Alaska Aroostook County, Maine Ashland County, Wisconsin Baraga County, Michigan Barnes County, North Dakota Bayfield County, Wisconsin Becker County, Minnesota Beltrami County, Minnesota Benson County, North Dakota Bottineau County, North Dakota Bristol Bay Borough, Alaska Burke County, North Dakota Burnett County, Wisconsin Carlton County, Minnesota Cass County, Minnesota

463

Climate Zone 2B | Open Energy Information  

Open Energy Info (EERE)

B B Jump to: navigation, search A type of climate defined in the ASHRAE 169-2006 standard consisting of Climate Zone Number 2 and Climate Zone Subtype B. Climate Zone 2B is defined as Dry with IP Units 6300 < CDD50ºF ≤ 9000 and SI Units 3500 < CDD10ºC ≤ 5000 . The following places are categorized as class 2B climate zones: Bandera County, Texas Dimmit County, Texas Edwards County, Texas Frio County, Texas Imperial County, California Kinney County, Texas La Paz County, Arizona La Salle County, Texas Maricopa County, Arizona Maverick County, Texas Medina County, Texas Pima County, Arizona Pinal County, Arizona Real County, Texas Uvalde County, Texas Val Verde County, Texas Webb County, Texas Yuma County, Arizona Zapata County, Texas Zavala County, Texas Retrieved from

464

Climate Zone 4A | Open Energy Information  

Open Energy Info (EERE)

A A Jump to: navigation, search A type of climate defined in the ASHRAE 169-2006 standard consisting of Climate Zone Number 4 and Climate Zone Subtype A. Climate Zone 4A is defined as Mixed - Humid with IP Units CDD50ºF ≤ 4500 AND 3600 < HDD65ºF ≤ 5400 and SI Units CDD10ºC ≤ 2500 AND HDD18ºC ≤ 3000 . The following places are categorized as class 4A climate zones: Accomack County, Virginia Adair County, Kentucky Adams County, Ohio Alamance County, North Carolina Albemarle County, Virginia Alexander County, Illinois Alexander County, North Carolina Alexandria County, Virginia Allegany County, Maryland Alleghany County, Virginia Allen County, Kansas Allen County, Kentucky Amelia County, Virginia Amherst County, Virginia Anderson County, Kansas Anderson County, Kentucky

465

Climate Zone 4B | Open Energy Information  

Open Energy Info (EERE)

B B Jump to: navigation, search A type of climate defined in the ASHRAE 169-2006 standard consisting of Climate Zone Number 4 and Climate Zone Subtype B. Climate Zone 4B is defined as Dry with IP Units CDD50ºF ≤ 4500 AND 3600 < HDD65ºF ≤ 5400 and SI Units CDD10ºC ≤ 2500 AND HDD18ºC ≤ 3000 . The following places are categorized as class 4B climate zones: Amador County, California Armstrong County, Texas Baca County, Colorado Bailey County, Texas Beaver County, Oklahoma Bernalillo County, New Mexico Briscoe County, Texas Calaveras County, California Carson County, Texas Castro County, Texas Cibola County, New Mexico Cimarron County, Oklahoma Cochran County, Texas Curry County, New Mexico Dallam County, Texas De Baca County, New Mexico Deaf Smith County, Texas

466

Climate Zone 6A | Open Energy Information  

Open Energy Info (EERE)

Jump to: navigation, search Jump to: navigation, search A type of climate defined in the ASHRAE 169-2006 standard consisting of Climate Zone Number 6 and Climate Zone Subtype A. Climate Zone 6A is defined as Cold - Humid with IP Units 7200 < HDD65ºF ≤ 9000 and SI Units 4000 < HDD18ºC ≤ 5000 . The following places are categorized as class 6A climate zones: Adams County, North Dakota Adams County, Wisconsin Addison County, Vermont Alcona County, Michigan Alger County, Michigan Allamakee County, Iowa Allegany County, New York Alpena County, Michigan Androscoggin County, Maine Anoka County, Minnesota Antrim County, Michigan Arenac County, Michigan Aurora County, South Dakota Barron County, Wisconsin Beadle County, South Dakota Belknap County, New Hampshire Bennington County, Vermont

467

Pine Tree Development Zones Program (Maine)  

Energy.gov (U.S. Department of Energy (DOE))

The Pine Tree Development Zones program offers eligible businesses the chance to reduce, and sometimes eliminate, state taxes for up to ten years. There is a statutory requirement of hiring a...

468

Climate Zone Number 8 | Open Energy Information  

Open Energy Info (EERE)

Datasets Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon Climate Zone Number 8 Jump to: navigation, search A type of climate defined in the ASHRAE...

469

Climate Zone 1A | Open Energy Information  

Open Energy Info (EERE)

Datasets Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon Climate Zone 1A Jump to: navigation, search A type of climate defined in the ASHRAE...

470

Microbial oceanography of anoxic oxygen minimum zones  

E-Print Network (OSTI)

Vast expanses of oxygen-deficient and nitrite-rich water define the major oxygen minimum zones (OMZs) of the global ocean. They support diverse microbial communities that influence the nitrogen economy of the oceans, ...

Ulloa, Osvaldo

471

Seismic imaging of the mantle transition zone  

E-Print Network (OSTI)

In this thesis, we developed a generalized Radon transform of SS precursors for large-scale, high-resolution seismo-stratigraphy of the upper mantle transition zone. The generalized Radon transform (GRT) is based on the ...

Cao, Qin, Ph. D. Massachusetts Institute of Technology

2012-01-01T23:59:59.000Z

472

Climate Zone 3C | Open Energy Information  

Open Energy Info (EERE)

C C Jump to: navigation, search A type of climate defined in the ASHRAE 169-2006 standard consisting of Climate Zone Number 3 and Climate Zone Subtype C. Climate Zone 3C is defined as Warm - Marine with IP Units CDD50ºF ≤ 4500 AND HDD65ºF ≤ 3600 and SI Units CDD10ºC ≤ 2500 AND HDD18ºC ≤ 2000 . The following places are categorized as class 3C climate zones: Alameda County, California Marin County, California Mendocino County, California Monterey County, California Napa County, California San Benito County, California San Francisco County, California San Luis Obispo County, California San Mateo County, California Santa Barbara County, California Santa Clara County, California Santa Cruz County, California Sonoma County, California Ventura County, California

473

Climate Zone 3A | Open Energy Information  

Open Energy Info (EERE)

A A Jump to: navigation, search A type of climate defined in the ASHRAE 169-2006 standard consisting of Climate Zone Number 3 and Climate Zone Subtype A. Climate Zone 3A is defined as Warm - Humid with IP Units 4500 < CDD50ºF ≤ 6300 and SI Units 2500 < CDD10ºC < 3500 . The following places are categorized as class 3A climate zones: Abbeville County, South Carolina Adair County, Oklahoma Adams County, Mississippi Aiken County, South Carolina Alcorn County, Mississippi Alfalfa County, Oklahoma Allendale County, South Carolina Amite County, Mississippi Anderson County, South Carolina Anson County, North Carolina Archer County, Texas Arkansas County, Arkansas Ashley County, Arkansas Atoka County, Oklahoma Attala County, Mississippi Autauga County, Alabama Baldwin County, Georgia

474

Fault trees for decision making in systems analysis  

SciTech Connect

The application of fault tree analysis (FTA) to system safety and reliability is presented within the framework of system safety analysis. The concepts and techniques involved in manual and automated fault tree construction are described and their differences noted. The theory of mathematical reliability pertinent to FTA is presented with emphasis on engineering applications. An outline of the quantitative reliability techniques of the Reactor Safety Study is given. Concepts of probabilistic importance are presented within the fault tree framework and applied to the areas of system design, diagnosis and simulation. The computer code IMPORTANCE ranks basic events and cut sets according to a sensitivity analysis. A useful feature of the IMPORTANCE code is that it can accept relative failure data as input. The output of the IMPORTANCE code can assist an analyst in finding weaknesses in system design and operation, suggest the most optimal course of system upgrade, and determine the optimal location of sensors within a system. A general simulation model of system failure in terms of fault tree logic is described. The model is intended for efficient diagnosis of the causes of system failure in the event of a system breakdown. It can also be used to assist an operator in making decisions under a time constraint regarding the future course of operations. The model is well suited for computer implementation. New results incorporated in the simulation model include an algorithm to generate repair checklists on the basis of fault tree logic and a one-step-ahead optimization procedure that minimizes the expected time to diagnose system failure. (80 figures, 20 tables) (auth)

Lambert, H.E.

1975-10-01T23:59:59.000Z

475

Zone control system for energy conservation  

SciTech Connect

A zone control system adapted to control temperatures in a building is described having a temperature modifying plant to modify the temperature of a heat exchange medium, circulator means to circulate the medium, and flow control means to regulate the flow of the medium. The system includes zone thermostats with one thermostat per controlled zone, and with each thermostat including temperature responsive means and heat anticipator means to modify the temperature of the temperature responsive means; at least one of the flow control means per controlled zone, and each of the flow control means being capable of energizing the circulator means when the flow control means operates to permit circulation of the heat exchange medium; each zone thermostat including on-off timer means having normally open switch means, and further including intermediate on timer means having normally open switch means; first zone control circuit means including a temperature responsive means of the first thermostat, a heat anticipator means of the first thermostat, and circuit means with normally closed switch means capable of energizing a first flow control means to an open position upon the first thermostat calling for operation of the temperature modifying plant. The timer means of the first thermostat is actuated by the first thermostat calling for operation of the temperature modifying plant; a first of the on-off timer means operating its switch means to an on state after a fixed time interval to latch the first flow control means into an open condition; a first of the intermediate on timer means operating its switch means to an on state after a second fixed time interval to energize the modifying plant and complete a circuit to a secondary anticipation heater of a second zone thermostat capable of adding heat to the second zone thermostat; and the first on-off timer means maintaining its switch means closed.

Nelson, L.W.

1986-04-15T23:59:59.000Z

476

Zone heated diesel particulate filter electrical connection  

DOE Patents (OSTI)

An electrical connection system for a particulate filter is provided. The system includes: a particulate filter (PF) disposed within an outer shell wherein the PF is segmented into a plurality of heating zones; an outer mat disposed between the particulate filter and the outer shell; an electrical connector coupled to the outer shell of the PF; and a plurality of printed circuit connections that extend along the outer surface of the PF from the electrical connector to the plurality of heating zones.

Gonze, Eugene V. (Pinckney, MI); Paratore, Jr., Michael J. (Howell, MI)

2010-03-30T23:59:59.000Z

477

U-PLANT GEOGRAPHIC ZONE CLEANUP PROTOTYPE  

Science Conference Proceedings (OSTI)

The U Plant geographic zone (UPZ) occupies 0.83 square kilometers on the Hanford Site Central Plateau (200 Area). It encompasses the U Plant canyon (221-U Facility), ancillary facilities that supported the canyon, soil waste sites, and underground pipelines. The UPZ cleanup initiative coordinates the cleanup of the major facilities, ancillary facilities, waste sites, and contaminated pipelines (collectively identified as ''cleanup items'') within the geographic zone. The UPZ was selected as a geographic cleanup zone prototype for resolving regulatory, technical, and stakeholder issues and demonstrating cleanup methods for several reasons: most of the area is inactive, sufficient characterization information is available to support decisions, cleanup of the high-risk waste sites will help protect the groundwater, and the zone contains a representative cross-section of the types of cleanup actions that will be required in other geographic zones. The UPZ cleanup demonstrates the first of 22 integrated zone cleanup actions on the Hanford Site Central Plateau to address threats to groundwater, the environment, and human health. The UPZ contains more than 100 individual cleanup items. Cleanup actions in the zone will be undertaken using multiple regulatory processes and decision documents. Cleanup actions will include building demolition, waste site and pipeline excavation, and the construction of multiple, large engineered barriers. In some cases, different cleanup actions may be taken at item locations that are immediately adjacent to each other. The cleanup planning and field activities for each cleanup item must be undertaken in a coordinated and cohesive manner to ensure effective execution of the UPZ cleanup initiative. The UPZ zone cleanup implementation plan (ZCIP) was developed to address the need for a fundamental integration tool for UPZ cleanup. As UPZ cleanup planning and implementation moves forward, the ZCIP is intended to be a living document that will provide a focal point for integrating UPZ actions, including field cleanup activities, waste staging and handling, and post-cleanup monitoring and institutional controls.

ROMINE, L.D.

2006-02-01T23:59:59.000Z

478

DEEP VADOSE ZONE TREATABILITY TEST PLAN  

Science Conference Proceedings (OSTI)

{sm_bullet} Treatability test plan published in 2008 {sm_bullet} Outlines technology treatability activities for evaluating application of in situ technologies and surface barriers to deep vadose zone contamination (technetium and uranium) {sm_bullet} Key elements - Desiccation testing - Testing of gas-delivered reactants for in situ treatment of uranium - Evaluating surface barrier application to deep vadose zone - Evaluating in situ grouting and soil flushing

GB CHRONISTER; MJ TRUEX

2009-07-02T23:59:59.000Z

479

Treating nahcolite containing formations and saline zones  

Science Conference Proceedings (OSTI)

A method for treating a nahcolite containing subsurface formation includes removing water from a saline zone in or near the formation. The removed water is heated using a steam and electricity cogeneration facility. The heated water is provided to the nahcolite containing formation. A fluid is produced from the nahcolite containing formation. The fluid includes at least some dissolved nahcolite. At least some of the fluid is provided to the saline zone.

Vinegar, Harold J

2013-06-11T23:59:59.000Z

480

LETTERS  

Science Conference Proceedings (OSTI)

... Fault mapping and palaeo- seismology at unconventional locations may be required to find out if places such as New Madrid and Charleston are ...

2010-11-09T23:59:59.000Z

Note: This page contains sample records for the topic "madrid fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.