Powered by Deep Web Technologies
Note: This page contains sample records for the topic "loading front loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Thermomechanical analysis of high-heat-load components for the canted-undulator front end.  

SciTech Connect

With the canted undulators operating at 200 mA at closed gap at the Advanced Photon Source in the future, the front end will receive 20.4 kW of total power and 281 kW/mrad{sup 2} of peak power density. Thermal analysis of the front-end high-heat-load components becomes an essential part of the front-end design. An extensive study has been conducted on the thermal design of the photon shutters and fixed masks. A unique dog-bone-shaped cross-section design for the photon shutters was derived to relieve high stress in the corners. The dual-undulator x-ray beams were simulated at several locations on the fixed mask to ensure the worst possible case is considered. Stress analysis on the fixed mask revealed that the maximum stress occurs when beam hits the intersection between the horizontal surface and the corner surface. The details of the analysis procedure are presented, and the failure criteria are discussed.

Jaski, Y.; Trakhtenberg, E.; Collins, J.; Benson, C.; Brajuskovic, B.; Den Hartog, P.

2002-09-20T23:59:59.000Z

2

Load cell  

DOE Patents (OSTI)

A load cell combines the outputs of a plurality of strain gauges to measure components of an applied load. Combination of strain gauge outputs allows measurement of any of six load components without requiring complex machining or mechanical linkages to isolate load components. An example six axis load cell produces six independent analog outputs, each directly proportional to one of the six general load components. 16 figs.

Spletzer, B.L.

1998-12-15T23:59:59.000Z

3

Load cell  

DOE Patents (OSTI)

A load cell combines the outputs of a plurality of strain gauges to measure components of an applied load. Combination of strain gauge outputs allows measurement of any of six load components without requiring complex machining or mechanical linkages to isolate load components. An example six axis load cell produces six independent analog outputs which can be combined to determine any one of the six general load components.

Spletzer, Barry L. (Albuquerque, NM)

2001-01-01T23:59:59.000Z

4

Load cell  

DOE Patents (OSTI)

A load cell combines the outputs of a plurality of strain gauges to measure components of an applied load. Combination of strain gauge outputs allows measurement of any of six load components without requiring complex machining or mechanical linkages to isolate load components. An example six axis load cell produces six independent analog outputs, each directly proportional to one of the six general load components.

Spletzer, Barry L. (Albuquerque, NM)

1998-01-01T23:59:59.000Z

5

Load Control  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Visualization and Controls Peer Review Visualization and Controls Peer Review Load Control for System Reliability and Measurement-Based Stability Assessment Dan Trudnowski, PhD, PE Montana Tech Butte, MT 59701 dtrudnowski@mtech.edu 406-496-4681 October 2006 2 Presentation Outline * Introduction - Goals, Enabling technologies, Overview * Load Control - Activities, Status * Stability Assessment - Activities, Status * Wrap up - Related activities, Staff 3 Goals * Research and develop technologies to improve T&D reliability * Technologies - Real-time load control methodologies - Measurement-based stability-assessment 4 Enabling Technologies * Load control enabled by GridWise technology (e.g. PNNL's GridFriendly appliance) * Real-time stability assessment enabled by Phasor Measurement (PMU) technology 5 Project Overview * Time line: April 18, 2006 thru April 17, 2008

6

LOADING DEVICE  

DOE Patents (OSTI)

A device is presented for loading or charging bodies of fissionable material into a reactor. This device consists of a car, mounted on tracks, into which the fissionable materials may be placed at a remote area, transported to the reactor, and inserted without danger to the operating personnel. The car has mounted on it a heavily shielded magazine for holding a number of the radioactive bodies. The magazine is of a U-shaped configuration and is inclined to the horizontal plane, with a cap covering the elevated open end, and a remotely operated plunger at the lower, closed end. After the fissionable bodies are loaded in the magazine and transported to the reactor, the plunger inserts the body at the lower end of the magazine into the reactor, then is withdrawn, thereby allowing gravity to roll the remaining bodies into position for successive loading in a similar manner.

Ohlinger, L.A.

1958-10-01T23:59:59.000Z

7

LOADED WAVEGUIDES  

DOE Patents (OSTI)

>Loaded waveguides are described for the propagation of electromagnetic waves with reduced phase velocities. A rectangular waveguide is dimensioned so as to cut-off the simple H/sub 01/ mode at the operating frequency. The waveguide is capacitance loaded, so as to reduce the phase velocity of the transmitted wave, by connecting an electrical conductor between directly opposite points in the major median plane on the narrower pair of waveguide walls. This conductor may take a corrugated shape or be an aperature member, the important factor being that the electrical length of the conductor is greater than one-half wavelength at the operating frequency. Prepared for the Second U.N. International ConferThe importance of nuclear standards is duscussed. A brief review of the international callaboration in this field is given. The proposal is made to let the International Organization for Standardization (ISO) coordinate the efforts from other groups. (W.D.M.)

Mullett, L.B.; Loach, B.G.; Adams, G.L.

1958-06-24T23:59:59.000Z

8

Periodic load balancing  

Science Conference Proceedings (OSTI)

Multiprocessor load balancing aims to improve performance by moving jobs from highly loaded processors to more lightly loaded processors. Some schemes allow only migration of new jobs upon arrival, while other schemes allow migration of ... Keywords: heavy traffic diffusion approximations, load balancing, periodic load balancing, reflected Brownian motion, resource sharing, transient behavior

Gísli Hjálmtýsson; Ward Whitt

1998-06-01T23:59:59.000Z

9

Battery loading device  

SciTech Connect

A battery loading device for loading a power source battery, built in small appliances having a battery loading chamber for selectively loading a number of cylindrical unit batteries or a one body type battery having the same voltage as a number of cylindrical unit batteries, whereby the one body type battery and the battery loading chamber are shaped similarly and asymmetrically in order to prevent the one body type battery from being inserted in the wrong direction.

Phara, T.; Suzuki, M.

1984-08-28T23:59:59.000Z

10

FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH  

E-Print Network (OSTI)

composition: The total load profile obtained from  load individual load types if  load profiles of individual load composition validation: Load profiles generated by the load 

Lesieutre, Bernard

2013-01-01T23:59:59.000Z

11

Load sensing system  

DOE Patents (OSTI)

A load sensing system inexpensively monitors the weight and temperature of stored nuclear material for long periods of time in widely variable environments. The system can include an electrostatic load cell that encodes weight and temperature into a digital signal which is sent to a remote monitor via a coaxial cable. The same cable is used to supply the load cell with power. When multiple load cells are used, vast

Sohns, Carl W. (Oak Ridge, TN); Nodine, Robert N. (Knoxville, TN); Wallace, Steven Allen (Knoxville, TN)

1999-01-01T23:59:59.000Z

12

Discharge circuits and loads  

SciTech Connect

This will be an overview in which some of the general properties of loads are examined: their interface with the energy storage and switching devices; general problems encountered with different types of loads; how load behavior and fault modes can impact on the design of a power conditioning system (PCS).

Sarjeant, W.J.

1980-10-15T23:59:59.000Z

13

Load sensing system  

DOE Patents (OSTI)

A load sensing system inexpensively monitors the weight and temperature of stored nuclear material for long periods of time in widely variable environments. The system can include an electrostatic load cell that encodes weight and temperature into a digital signal which is sent to a remote monitor via a coaxial cable. The same cable is used to supply the load cell with power. When multiple load cells are used, vast inventories of stored nuclear material can be continuously monitored and inventoried of minimal cost. 4 figs.

Sohns, C.W.; Nodine, R.N.; Wallace, S.A.

1999-05-04T23:59:59.000Z

14

Structural load combinations  

SciTech Connect

This paper presents the latest results of the program entitled, ''Probability Based Load Combinations For Design of Category I Structures''. In FY 85, a probability-based reliability analysis method has been developed to evaluate safety of shear wall structures. The shear walls are analyzed using stick models with beam elements and may be subjected to dead load, live load and in-plane eqrthquake. Both shear and flexure limit states are defined analytically. The limit state probabilities can be evaluated on the basis of these limit states. Utilizing the reliability analysis method mentioned above, load combinations for the design of shear wall structures have been established. The proposed design criteria are in the load and resistance factor design (LRFD) format. In this study, the resistance factors for shear and flexure and load factors for dead and live loads are preassigned, while the load factor for SSE is determined for a specified target limit state probability of 1.0 x 10/sup -6/ or 1.0 x 10/sup -5/ during a lifetime of 40 years. 23 refs., 9 tabs.

Hwang, H.; Reich, M.; Ellingwood, B.; Shinozuka, M.

1985-01-01T23:59:59.000Z

15

Watershed Mercury Loading Framework  

Science Conference Proceedings (OSTI)

This report explains and illustrates a simplified stochastic framework, the Watershed Mercury Loading Framework, for organizing and framing site-specific knowledge and information on mercury loading to waterbodies. The framework permits explicit treatment of data uncertainties. This report will be useful to EPRI members, state and federal regulatory agencies, and watershed stakeholders concerned with mercury-related human and ecological health risk.

2003-05-23T23:59:59.000Z

16

load | OpenEI  

Open Energy Info (EERE)

load load Dataset Summary Description This dataset contains hourly load profile data for 16 commercial building types (based off the DOE commercial reference building models) and residential buildings (based off the Building America House Simulation Protocols). This dataset also includes the Residential Energy Consumption Survey (RECS) for statistical references of building types by location. Source Commercial and Residential Reference Building Models Date Released April 18th, 2013 (9 months ago) Date Updated July 02nd, 2013 (7 months ago) Keywords building building demand building load Commercial data demand Energy Consumption energy data hourly kWh load profiles Residential Data Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Annually

17

Load-management decision  

Science Conference Proceedings (OSTI)

Utilities require baseload, intermediate, and peaking plants to meet fluctuating customer demand. These can be supplemented with off-peak generation and storage and load management, which can take the form of direct utility control over interruptible and deferrable customers or customer incentives that require off-peak demand. Utilities should make a careful analysis of their load profile, their generation mix, their ability to shift loads, and customer attitudes before deciding on a load-management program that fits their individual needs. They should also be aware that load management is only a limited resource with a number of uncertainties. Research programs into customer relations, system reliability, communications devices, and special control switches and meters will help to relieve some of the uncertainties. (DCK)

Lihach, N.; Gupta, P.

1982-05-01T23:59:59.000Z

18

HLW Glass Waste Loadings  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HLW HLW Glass Waste Loadings Ian L. Pegg Vitreous State Laboratory The Catholic University of America Washington, DC Overview Overview  Vitrification - general background  Joule heated ceramic melter (JHCM) technology  Factors affecting waste loadings  Waste loading requirements and projections  WTP DWPF  DWPF  Yucca Mountain License Application requirements on waste loading  Summary Vitrification  Immobilization of waste by conversion into a glass  Internationally accepted treatment for HLW  Why glass?  Amorphous material - able to incorporate a wide spectrum of elements over wide ranges of composition; resistant to radiation damage  Long-term durability - natural analogs Relatively simple process - amenable to nuclearization at large  Relatively simple process - amenable to nuclearization at large scale  There

19

OpenEI - load  

Open Energy Info (EERE)

are given by a location defined by the Typical Meteorological Year (TMY) for which the weather data was collected. Commercial load data is sorted by the (TMY) site as a...

20

building load data | OpenEI Community  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Load data Image source: NREL...

Note: This page contains sample records for the topic "loading front loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

electric load data | OpenEI Community  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Load data Image source: NREL...

22

commercial load | OpenEI Community  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Load data Image source: NREL...

23

residential load | OpenEI Community  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Load data Image source: NREL...

24

Composite Load Model Evaluation  

Science Conference Proceedings (OSTI)

The WECC load modeling task force has dedicated its effort in the past few years to develop a composite load model that can represent behaviors of different end-user components. The modeling structure of the composite load model is recommended by the WECC load modeling task force. GE Energy has implemented this composite load model with a new function CMPLDW in its power system simulation software package, PSLF. For the last several years, Bonneville Power Administration (BPA) has taken the lead and collaborated with GE Energy to develop the new composite load model. Pacific Northwest National Laboratory (PNNL) and BPA joint force and conducted the evaluation of the CMPLDW and test its parameter settings to make sure that: • the model initializes properly, • all the parameter settings are functioning, and • the simulation results are as expected. The PNNL effort focused on testing the CMPLDW in a 4-bus system. An exhaustive testing on each parameter setting has been performed to guarantee each setting works. This report is a summary of the PNNL testing results and conclusions.

Lu, Ning; Qiao, Hong (Amy)

2007-09-30T23:59:59.000Z

25

Analysis of industrial load management  

SciTech Connect

Industrial Load Management, ILM, has increased the possibilities of changing load profiles and raising load factors. This paper reports on load profile measurements and feasible load management applications that could be implemented in industry e.g. bivalent systems for heating of premises and processes, load priority systems, energy storage and rescheduling processes or parts of processes due to differential electricity rates. Industrial load variations on hourly, daily and seasonal basis are treated as well as the impact by load management on load curves e g peak clipping, valley filling and increased off-peak electricity usage.

Bjork, C.O.; Karlsson, B.G.

1986-04-01T23:59:59.000Z

26

Distribution substation load impacts of residential air conditioner load control  

SciTech Connect

An ongoing experiment to monitor the substation level load impacts of end-use load control is described. An overview of the data acquisition system, experimental procedures and analysis techniques are provided. Results of the 1983 and 1984 experiments demonstrate the value of aggregate load impact monitoring as a means of verifying load research results, calculating the diversity of end-use loads, and predicting the impacts of load management on the transmission and distribution systems.

Heffner, G.C.; Kaufman, D.A.

1985-07-01T23:59:59.000Z

27

Load Monitoring CEC/LMTF Load Research Program  

SciTech Connect

This white paper addresses the needs, options, current practices of load monitoring. Recommendations on load monitoring applications and future directions are also presented.

Huang, Zhenyu; Lesieutre, B.; Yang, Steve; Ellis, A.; Meklin, A.; Wong, B.; Gaikwad, A.; Brooks, D.; Hammerstrom, Donald J.; Phillips, John; Kosterev, Dmitry; Hoffman, M.; Ciniglio, O.; Hartwell, R.; Pourbeik, P.; Maitra, A.; Lu, Ning

2007-11-30T23:59:59.000Z

28

Mass-Loaded Flows  

E-Print Network (OSTI)

A key process within astronomy is the exchange of mass, momentum, and energy between diffuse plasmas in many types of astronomical sources (including planetary nebulae, wind-blown bubbles, supernova remnants, starburst superwinds, and the intracluster medium) and dense, embedded clouds or clumps. This transfer affects the large scale flows of the diffuse plasmas as well as the evolution of the clumps. I review our current understanding of mass-injection processes, and examine intermediate-scale structure and the global effect of mass-loading on a flow. I then discuss mass-loading in a variety of diffuse sources.

J. M. Pittard

2006-07-13T23:59:59.000Z

29

Cooling load estimation methods  

DOE Green Energy (OSTI)

Ongoing research on quantifying the cooling loads in residential buildings, particularly buildings with passive solar heating systems, is described. Correlations are described that permit auxiliary cooling estimates from monthly average insolation and weather data. The objective of the research is to develop a simple analysis method, useful early in design, to estimate the annual cooling energy required of a given building.

McFarland, R.D.

1984-01-01T23:59:59.000Z

30

LOADING AND UNLOADING DEVICE  

DOE Patents (OSTI)

A device for loading and unloading fuel rods into and from a reactor tank through an access hole includes parallel links carrying a gripper. These links enable the gripper to go through the access hole and then to be moved laterally from the axis of the access hole to the various locations of the fuel rods in the reactor tank.

Treshow, M.

1960-08-16T23:59:59.000Z

31

Multidimensional spectral load balancing  

DOE Patents (OSTI)

A method of and apparatus for graph partitioning involving the use of a plurality of eigenvectors of the Laplacian matrix of the graph of the problem for which load balancing is desired. The invention is particularly useful for optimizing parallel computer processing of a problem and for minimizing total pathway lengths of integrated circuits in the design stage.

Hendrickson, Bruce A. (Albuquerque, NM); Leland, Robert W. (Albuquerque, NM)

1996-12-24T23:59:59.000Z

32

Buildings Stock Load Control  

E-Print Network (OSTI)

Researchers and practitioners have proposed a variety of solutions to reduce electricity consumption and curtail peak demand. This research focuses on electricity demand control by applying some strategies in existing building to reduce it during the extreme climate period. The first part of this paper presents the objectives of the study: ? to restrict the startup polluting manufacturing units (power station), ? to limit the environmental impacts (greenhouse emission), ? to reduce the transport and distribution electricity infrastructures The second part presents the approach used to rise the objectives : ? To aggregat the individual loads and to analyze the impact of different strategies from load shedding to reduce peak power demand by: ? Developing models of tertiary buildings stocks (Schools, offices, Shops, hotels); ? Making simulations for different load shedding strategies to calculate potential peak power saving. The third part is dedicated to the description of the developed models: An assembly of the various blocks of the library of simbad and simulink permit to model building. Finally the last part prensents the study results: Graphs and tables to see the load shedding strategies impacts.

Joutey, H. A.; Vaezi-Nejad, H.; Clemoncon, B.; Rosenstein, F.

2006-01-01T23:59:59.000Z

33

OpenEI Community - load data  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Utility Rate OpenEI Community...

34

OpenEI Community - electric load data  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Utility Rate OpenEI Community...

35

OpenEI Community - building load  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Utility Rate OpenEI Community...

36

OpenEI Community - residential load  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Utility Rate OpenEI Community...

37

OpenEI Community - commercial load  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Utility Rate OpenEI Community...

38

OpenEI Community - building load data  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Utility Rate OpenEI Community...

39

Load Capacity of Bodies  

E-Print Network (OSTI)

For the stress analysis in a plastic body $\\Omega$, we prove that there exists a maximal positive number $C$, the \\emph{load capacity ratio,} such that the body will not collapse under any external traction field $t$ bounded by $Y_{0}C$, where $Y_0$ is the elastic limit. The load capacity ratio depends only on the geometry of the body and is given by $$ \\frac{1}{C}=\\sup_{w\\in LD(\\Omega)_D} \\frac{\\int_{\\partial\\Omega}|w|dA} {\\int_{\\Omega}|\\epsilon(w)|dV}=\\left\\|\\gamma_D\\right\\|. $$ Here, $LD(\\Omega)_D$ is the space of isochoric vector fields $w$ for which the corresponding stretchings $\\epsilon(w)$ are assumed to be integrable and $\\gamma_D$ is the trace mapping assigning the boundary value $\\gamma_D(w)$ to any $w\\in LD(\\Omega)_D$.

Reuven Segev

2005-11-01T23:59:59.000Z

40

Load responsive hydrodynamic bearing  

Science Conference Proceedings (OSTI)

A load responsive hydrodynamic bearing is provided in the form of a thrust bearing or journal bearing for supporting, guiding and lubricating a relatively rotatable member to minimize wear thereof responsive to relative rotation under severe load. In the space between spaced relatively rotatable members and in the presence of a liquid or grease lubricant, one or more continuous ring shaped integral generally circular bearing bodies each define at least one dynamic surface and a plurality of support regions. Each of the support regions defines a static surface which is oriented in generally opposed relation with the dynamic surface for contact with one of the relatively rotatable members. A plurality of flexing regions are defined by the generally circular body of the bearing and are integral with and located between adjacent support regions. Each of the flexing regions has a first beam-like element being connected by an integral flexible hinge with one of the support regions and a second beam-like element having an integral flexible hinge connection with an adjacent support region. A least one local weakening geometry of the flexing region is located intermediate the first and second beam-like elements. In response to application of load from one of the relatively rotatable elements to the bearing, the beam-like elements and the local weakening geometry become flexed, causing the dynamic surface to deform and establish a hydrodynamic geometry for wedging lubricant into the dynamic interface.

Kalsi, Manmohan S. (Houston, TX); Somogyi, Dezso (Sugar Land, TX); Dietle, Lannie L. (Stafford, TX)

2002-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "loading front loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Variable loading roller  

DOE Patents (OSTI)

An automatic loading roller for transmitting torque in traction drive devices in manipulator arm joints includes a two-part camming device having a first cam portion rotatable in place on a shaft by an input torque and a second cam portion coaxially rotatable and translatable having a rotating drive surface thereon for engaging the driven surface of an output roller with a resultant force proportional to the torque transmitted. Complementary helical grooves in the respective cam portions interconnected through ball bearings interacting with those grooves effect the rotation and translation of the second cam portion in response to rotation of the first. 14 figs.

Williams, D.M.

1988-01-21T23:59:59.000Z

42

MTS Table Top Load frame  

NLE Websites -- All DOE Office Websites (Extended Search)

MTS Table Top Load frame MTS Table Top Load frame The Non-destructive Evaluation group operates an MTS Table Top Load frame for ultimate strength and life cycle testing of various ceramic, ceramic-matrix (FGI), carbon, carbon fiber, cermet (CMC) and metal alloy engineering samples. The load frame is a servo-hydraulic type designed to function in a closed loop configuration under computer control. The system can perform non-cyclic, tension, compression and flexure testing and cyclic fatigue tests. The system is comprised of two parts: * The Load Frame and * The Control System. Load Frame The Load Frame (figure 1) is a cross-head assembly which includes a single moving grip, a stationary grip and LVDT position sensor. It can generate up to 25 kN (5.5 kip) of force in the sample under test and can

43

Load Management: Opportunity or Calamity?  

E-Print Network (OSTI)

After the change in the economics of generating electricity which took place in 1973, many utilities are examining options to hold down their costs. One fact which is clear is that the difference between peak and off peak generating costs is much larger now than prior to 1973. Utilities are examining two options which can be termed load management. One option is to control discretionary loads during peak periods. Cycling of residential water heaters or shutting off industrial electric furnaces during peak periods are both examples of load control which lower the costs borne by the utility. The other option is the use of seasonal surcharges or time-of-day rates to induce customers to alter their usage patterns. Both these load management options focus on reducing utility costs overall without regard to the cost to the consumers affected by the load management options. The issue, then, is whether industrial customers can find opportunities to lower their costs under load management.

Males, R.; Hassig, N.

1981-01-01T23:59:59.000Z

44

Dynamic load balancing of applications  

DOE Patents (OSTI)

An application-level method for dynamically maintaining global load balance on a parallel computer, particularly on massively parallel MIMD computers. Global load balancing is achieved by overlapping neighborhoods of processors, where each neighborhood performs local load balancing. The method supports a large class of finite element and finite difference based applications and provides an automatic element management system to which applications are easily integrated.

Wheat, Stephen R. (Albuquerque, NM)

1997-01-01T23:59:59.000Z

45

Dynamic load balancing of applications  

DOE Patents (OSTI)

An application-level method for dynamically maintaining global load balance on a parallel computer, particularly on massively parallel MIMD computers is disclosed. Global load balancing is achieved by overlapping neighborhoods of processors, where each neighborhood performs local load balancing. The method supports a large class of finite element and finite difference based applications and provides an automatic element management system to which applications are easily integrated. 13 figs.

Wheat, S.R.

1997-05-13T23:59:59.000Z

46

Alaska Village Electric Load Calculator  

DOE Green Energy (OSTI)

As part of designing a village electric power system, the present and future electric loads must be defined, including both seasonal and daily usage patterns. However, in many cases, detailed electric load information is not readily available. NREL developed the Alaska Village Electric Load Calculator to help estimate the electricity requirements in a village given basic information about the types of facilities located within the community. The purpose of this report is to explain how the load calculator was developed and to provide instructions on its use so that organizations can then use this model to calculate expected electrical energy usage.

Devine, M.; Baring-Gould, E. I.

2004-10-01T23:59:59.000Z

47

High-Power Rf Load  

DOE Patents (OSTI)

A compact high-power RF load comprises a series of very low Q resonators, or chokes [16], in a circular waveguide [10]. The sequence of chokes absorb the RF power gradually in a short distance while keeping the bandwidth relatively wide. A polarizer [12] at the input end of the load is provided to convert incoming TE.sub.10 mode signals to circularly polarized TE.sub.11 mode signals. Because the load operates in the circularly polarized mode, the energy is uniformly and efficiently absorbed and the load is more compact than a rectangular load. Using these techniques, a load having a bandwidth of 500 MHz can be produced with an average power dissipation level of 1.5 kW at X-band, and a peak power dissipation of 100 MW. The load can be made from common lossy materials, such as stainless steel, and is less than 15 cm in length. These techniques can also produce loads for use as an alternative to ordinary waveguide loads in small and medium RF accelerators, in radar systems, and in other microwave applications. The design is easily scalable to other RF frequencies and adaptable to the use of other lossy materials.

Tantawi, Sami G. (San Mateo, CA); Vlieks, Arnold E. (Livermore, CA)

1998-09-01T23:59:59.000Z

48

Static identification of delinquent loads  

E-Print Network (OSTI)

The effective use of processor caches is crucial to the performance of applications. It has been shown that cache misses are not evenly distributed throughout a program. In applications running on RISC-style processors, a small number of delinquent load instructions are responsible for most of the cache misses. Identification of delinquent loads is the key to the success of many cache optimization and prefetching techniques. In this paper, we propose a method for identifying delinquent loads that can be implemented at compile time. Our experiments over eighteen benchmarks from the SPEC suite shows that our proposed scheme is stable across benchmarks, inputs, and cache structures, identifying an average of 10 % of the total number of loads in the benchmarks we tested that account for over 90 % of all data cache misses. As far as we know, this is the first time a technique for static delinquent load identification with such a level of precision and coverage has been reported. While comparable techniques can also identify load instructions that cover 90 % of all data cache misses, they do so by selecting over 50 % of all load instructions in the code, resulting in a high number of false positives. If basic block profiling is used in conjunction with our heuristic, then our results show that it is possible to pin down just 1.3 % of the load instructions that account for 82 % of all data cache misses. 1.

Vlad-mihai Panait; Amit Sasturkar Ý

2004-01-01T23:59:59.000Z

49

LOAD FORECASTING Eugene A. Feinberg  

E-Print Network (OSTI)

's electricity price forecasting model, produces forecast of gas demand consistent with electric load. #12Gas demand Council's Market Price of Electricity Forecast Natural GasDemand Electric Load Aggregating Natural between the natural gas and electricity and new uses of natural gas emerge. T natural gas forecasts

Feinberg, Eugene A.

50

building load | OpenEI  

Open Energy Info (EERE)

load load Dataset Summary Description This dataset contains hourly load profile data for 16 commercial building types (based off the DOE commercial reference building models) and residential buildings (based off the Building America House Simulation Protocols). This dataset also includes the Residential Energy Consumption Survey (RECS) for statistical references of building types by location. Source Commercial and Residential Reference Building Models Date Released April 18th, 2013 (9 months ago) Date Updated July 02nd, 2013 (7 months ago) Keywords building building demand building load Commercial data demand Energy Consumption energy data hourly kWh load profiles Residential Data Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Annually

51

Wind load reduction for heliostats  

DOE Green Energy (OSTI)

This report presents the results of wind-tunnel tests supported through the Solar Energy Research Institute (SERI) by the Office of Solar Thermal Technology of the US Department of Energy as part of the SERI research effort on innovative concentrators. As gravity loads on drive mechanisms are reduced through stretched-membrane technology, the wind-load contribution of the required drive capacity increases in percentage. Reduction of wind loads can provide economy in support structure and heliostat drive. Wind-tunnel tests have been directed at finding methods to reduce wind loads on heliostats. The tests investigated primarily the mean forces, moments, and the possibility of measuring fluctuating forces in anticipation of reducing those forces. A significant increase in ability to predict heliostat wind loads and their reduction within a heliostat field was achieved.

Peterka, J.A.; Hosoya, N.; Bienkiewicz, B.; Cermak, J.E.

1986-05-01T23:59:59.000Z

52

load data | OpenEI Community  

Open Energy Info (EERE)

51 51 Varnish cache server Home Groups Community Central Green Button Applications Developer Utility Rate FRED: FRee Energy Database More Public Groups Private Groups Features Groups Blog posts Content Stream Documents Discussions Polls Q & A Events Notices My stuff Energy blogs 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation: XID: 2142234851 Varnish cache server load data Home Sfomail's picture Submitted by Sfomail(48) Member 17 May, 2013 - 12:03 Commercial and Residential Hourly Load Data Now Available on OpenEI! building load building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Load data Image source: NREL Files: application/zip icon System Advisor Model Tool for Downloading Load Data

53

Spinning Reserve from Responsive Load  

SciTech Connect

As power system costs rise and capacity is strained demand response can provide a significant system reliability benefit at a potentially attractive cost. The 162 room Music Road Hotel in Pigeon Forge Tennessee agreed to host a spinning reserve test. The Tennessee Valley Authority (TVA) supplied real-time metering and monitoring expertise to record total hotel load during both normal operations and testing. Preliminary testing showed that hotel load can be curtailed by 22% to 37% depending on the outdoor temperature and the time of day. The load drop was very rapid, essentially as fast as the 2 second metering could detect.

Kueck, John D [ORNL; Kirby, Brendan J [ORNL; Laughner, T [Tennessee Valley Authority (TVA); Morris, K [Tennessee Valley Authority (TVA)

2009-01-01T23:59:59.000Z

54

Advanced nonintrusive load monitoring system  

E-Print Network (OSTI)

There is a need for flexible, inexpensive metering technologies that can be deployed in many different monitoring scenarios. Individual loads may be expected to compute information about their power consumption. Utility ...

Wichakool, Warit, 1977-

2011-01-01T23:59:59.000Z

55

OpenEI - building load  

Open Energy Info (EERE)

are given by a location defined by the Typical Meteorological Year (TMY) for which the weather data was collected. Commercial load data is sorted by the (TMY) site as a...

56

Permanent Load Shift Control Strategies  

NLE Websites -- All DOE Office Websites (Extended Search)

of Permanent Load Shifting for HVAC and other storage assets as it relates to summer on-peak demand, how it can be dynamically and autonomously controlled, and its relationship...

57

Building load control and optimization  

E-Print Network (OSTI)

Researchers and practitioners have proposed a variety of solutions to reduce electricity consumption and curtail peak demand. This research focuses on load control by improving the operations in existing building HVAC ...

Xing, Hai-Yun Helen, 1976-

2004-01-01T23:59:59.000Z

58

Load transfer coupling regression curve fitting for distribution load forecasting  

SciTech Connect

The planning of distribution facilities requires forecasts of future substation and feeder loads. Extrapolation based on a curve fit to past annual peak loads is currently the most popular manner of accomplishing this forecast. Curve fitting suffers badly from data shifts caused by switching as loads are routinely moved from one substation to another during the course of utility operations. This switching contaminates the data, reducing forecast accuracy. A new regression application reduces error due to these transfers by over an order of magnitude. A key to the usefulness of this method is that the amount of the transfer, and its direction (whether it was to or from a substation), is not a required input. The new technique, aspects of computer implementation of it, and a series of tests showing its advantage over normal multiple regression methods are given.

Willis, H.L.; Powell, R.W.

1984-05-01T23:59:59.000Z

59

Realizing load reduction functions by aperiodic switching of load groups  

SciTech Connect

This paper investigates the problem of scheduling ON/OFF switching of residential appliances under the control of a Load Management System (LMS). The scheduling process is intended to reduce the controlled appliances` power demand in accordance with a predefined load reduction profile. To solve this problem, a solution approach, based on the methodology of Pulse Width Modulation (PWM), is introduced. This approach provides a flexible mathematical basis for studying different aspects of the scheduling problem. The conventional practices in this area are shown to be special cases of the PWM technique. By applying the PWM-based technique to the scheduling problem, important classes of scheduling errors are identified and analytical expressions describing them are derived. These expressions are shown to provide sufficient information to compensate for the errors. Detailed simulations of load groups` response to switching actions are use to support conclusions of this study.

Navid-Azarbaijani, N. [McGill Univ., Montreal, Quebec (Canada). Dept. of Electrical Engineering; Banakar, M.H. [CAE Electronics Ltd., St. Laurent, Quebec (Canada)

1996-05-01T23:59:59.000Z

60

FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH  

E-Print Network (OSTI)

PSLF that incorporates motor  A?C, ZIP, and electronic load the fractions motors A?C, ZIP, and electronic loads.    Usethat incorporates motor  A?C, ZIP, and  electronic load 

Lesieutre, Bernard

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "loading front loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

load profile | OpenEI Community  

Open Energy Info (EERE)

load profile Home Sfomail's picture Submitted by Sfomail(48) Member 17 May, 2013 - 13:03 Commercial and Residential Hourly Load Data Now Available on OpenEI building load building...

62

Monthly Crustal Loading Corrections for Satellite Altimetry  

Science Conference Proceedings (OSTI)

Satellite altimeter measurements of sea surface height include a small contribution from vertical motion of the seafloor caused by crustal loading. Loading by ocean tides is routinely allowed for in altimeter data processing. Here, loading by ...

R. D. Ray; S. B. Luthcke; T. van Dam

2013-05-01T23:59:59.000Z

63

Peak load management: Potential options  

SciTech Connect

This report reviews options that may be alternatives to transmission construction (ATT) applicable both generally and at specific locations in the service area of the Bonneville Power Administration (BPA). Some of these options have potential as specific alternatives to the Shelton-Fairmount 230-kV Reinforcement Project, which is the focus of this study. A listing of 31 peak load management (PLM) options is included. Estimated costs and normalized hourly load shapes, corresponding to the respective base load and controlled load cases, are considered for 15 of the above options. A summary page is presented for each of these options, grouped with respect to its applicability in the residential, commercial, industrial, and agricultural sectors. The report contains comments on PLM measures for which load shape management characteristics are not yet available. These comments address the potential relevance of the options and the possible difficulty that may be encountered in characterizing their value should be of interest in this investigation. The report also identifies options that could improve the efficiency of the three customer utility distribution systems supplied by the Shelton-Fairmount Reinforcement Project. Potential cogeneration options in the Olympic Peninsula are also discussed. These discussions focus on the options that appear to be most promising on the Olympic Peninsula. Finally, a short list of options is recommended for investigation in the next phase of this study. 9 refs., 24 tabs.

Englin, J.E.; De Steese, J.G.; Schultz, R.W.; Kellogg, M.A.

1989-10-01T23:59:59.000Z

64

Building Energy Software Tools Directory: Load Express  

NLE Websites -- All DOE Office Websites (Extended Search)

graphical interface makes Load Express a powerful engineering tool with a very short learning curve. The "rookie" or experienced user can quickly and accurately perform load...

65

Self-aligning biaxial load frame  

DOE Patents (OSTI)

An self-aligning biaxial loading apparatus for use in testing the strength of specimens while maintaining a constant specimen centroid during the loading operation. The self-aligning biaxial loading apparatus consists of a load frame and two load assemblies for imparting two independent perpendicular forces upon a test specimen. The constant test specimen centroid is maintained by providing elements for linear motion of the load frame relative to a fixed cross head, and by alignment and linear motion elements of one load assembly relative to the load frame. 3 figures.

Ward, M.B.; Epstein, J.S.; Lloyd, W.R.

1994-01-18T23:59:59.000Z

66

Decentralized customerlevel under frequency load shedding in...  

Open Energy Info (EERE)

enables the management of large groups of distributed loads under a single innovative control schemes to use the flexibility of electrical loads for power system purposes....

67

Method for loading resin beds  

DOE Patents (OSTI)

An improved method of preparing nuclear reactor fuel by carbonizing a uranium loaded cation exchange resin provided by contacting a H.sup.+ loaded resin with a uranyl nitrate solution deficient in nitrate, comprises providing the nitrate deficient solution by a method comprising the steps of reacting in a reaction zone maintained between about 145.degree.-200.degree. C, a first aqueous component comprising a uranyl nitrate solution having a boiling point of at least 145.degree. C with a second aqueous component to provide a gaseous phase containing HNO.sub.3 and a reaction product comprising an aqueous uranyl nitrate solution deficient in nitrate.

Notz, Karl J. (Oak Ridge, TN); Rainey, Robert H. (Knoxville, TN); Greene, Charles W. (Knoxville, TN); Shockley, William E. (Oak Ridge, TN)

1978-01-01T23:59:59.000Z

68

PRB rail loadings shatter record  

Science Conference Proceedings (OSTI)

Rail transport of coal in the Powder River Basin has expanded, with a record 2,197 trains loaded in a month. Arch Coal's Thunder basin mining complex has expanded by literally bridging the joint line railway. The dry fork mine has also celebrated its safety achievements. 4 photos.

Buchsbaum, L.

2008-09-15T23:59:59.000Z

69

Automatic Electric Load Identification in  

E-Print Network (OSTI)

Abstract — A microgrid is the power system of choice for the electrification of rural areas in developing countries. It should be able to adapt to changing load situations without the need for specialists to change the configuration of the microgrid controller. This paper proposes a self-configuring microgrid management system that is able to adjust both generation and demand of the system, so that also in case of growing electricity demand the grid can still be operable by disconnecting unessential loads. A crucial task for the microgrid controller is to automatically identify the connected loads on the basis of their consumption behaviors. For this, a template-matching algorithm is proposed that is based on Dynamic Time Warping, which is primarily used in speech recognition. It has been found that for load profile analysis, simple signal features such as the number of rising edges or the aggregated energy consumption in a given time window is sufficient to describe the signal. In contrast to speech recognition, frequency domain analysis is not necessary.

Self-configuring Microgrids; Friederich Kupzog; Tehseen Zia; Adeel Abbas Zaidi

2009-01-01T23:59:59.000Z

70

On-line load relief control  

SciTech Connect

This paper describes the results of an investigation concerning the on-line prediction and enhancement of load relief. The effects of voltage fluctuation, system voltage profile control and generator voltage adjustment on load relief and load shedding operations during under-frequency transients are studied. The technique promoted in the paper may be used to reduce system spinning reserve or prospective load shedding.

Jovanovic, S.; Fox, B.; Thompson, J.G. (Queen' s Univ. of Belfast (United Kingdom))

1994-11-01T23:59:59.000Z

71

Load Forecasting for Modern Distribution Systems  

Science Conference Proceedings (OSTI)

Load forecasting is a fundamental activity for numerous organizations and activities within a utility, including planning, operations, and control. Transmission and Distribution (T&D) planning and design engineers use the load forecast to determine whether any changes and additions are needed to the electric system to satisfy the anticipated load. Other load forecast users include system operations, financial ...

2013-03-08T23:59:59.000Z

72

Load Forecast For use in Resource Adequacy  

E-Print Network (OSTI)

Load Forecast 2019 For use in Resource Adequacy Massoud Jourabchi #12;In today's presentation d l­ Load forecast methodology ­ Drivers of the forecast f i­ Treatment of conservation ­ Incorporating impact of weather ­ Forecast for 2019 #12;Regional Loads (MWA and MW)Regional Loads (MWA and MW

73

Evolving non-intrusive load monitoring  

Science Conference Proceedings (OSTI)

Non-intrusive load monitoring (NILM) identifies used appliances in a total power load according to their individual load characteristics. In this paper we propose an evolutionary optimization algorithm to identify appliances, which are modeled as on/off ... Keywords: NILM, evolution, evolutionary algorithm, knapsack problem, non-intrusive load monitoring

Dominik Egarter; Anita Sobe; Wilfried Elmenreich

2013-04-01T23:59:59.000Z

74

Characterizing Household Plug Loads through Self-Administered Load Research  

Science Conference Proceedings (OSTI)

Household miscellaneous loads, which include consumer electronics, are the fastest growing segment of household energy use in the United States. Although the relative energy intensity of applications such as heating and cooling is declining, the DOEAnnual Energy Outlook forecasts that the intensity of residential miscellaneous end uses will increase substantially by 2030. Studies by TIAX and Ecos Consulting reveal that miscellaneous devices8212smaller devices in terms of energy draw but growing in usage8...

2009-12-09T23:59:59.000Z

75

Load-shape development aids planning  

SciTech Connect

The concept that provides capable, load-shape development, is being adopted by several utilities and power pools. Public Service Electric and Gas Company has developed a computer simulation model that can predict a utility's load shape for up to a 30-year period. The objective of the PSE and G model, known as EICS (Electric Load-Curve Synthesis) is to provide a demand profile, to examine the impact of load mangement and other activities upon a system's load shape, and to apply appropriate forecast non-load-management and load-management impacts before finally examining the resulting revised load-shape. Other models dealing with load-shape are discussed. Specifically, the Systems Control Inc. model for EPRI (SCI/EPRI), useful in performing accurate simulations of various load-control strategies involving customer appliance control is mentioned.

Gellings, C.W.

1979-12-15T23:59:59.000Z

76

Load Scheduling with Profile Information  

E-Print Network (OSTI)

. Within the past five years, many manufactures have added hardware performance counters to their microprocessors to generate profile data cheaply. We show how to use Compaq's DCPI tool to determine load latencies which are at a fine, instruction granularity and use them as fodder for improving instruction scheduling. We validate our heuristic for using DCPI latency data to classify loads as hits and misses against simulation numbers. We map our classification into the Multiflow compiler's intermediate representation, and use a locality sensitive Balanced scheduling algorithm. Our experiments illustrate that our algorithm improves run times by 1% on average, but up to 10% on a Compaq Alpha. 1 Introduction This paper explores how to use hardware performance counters to produce fine grain latency information to improve compiler scheduling. We use this information to hide latencies with any available instruction level parallelism (ILP). (ILP for an instruction is the number of o...

Götz Lindenmaier; Kathryn S. McKinley; Olivier Temam

2000-01-01T23:59:59.000Z

77

PASSIVE DETECTION OF VEHICLE LOADING  

SciTech Connect

The Digital Imaging and Remote Sensing Laboratory (DIRS) at the Rochester Institute of Technology, along with the Savannah River National Laboratory is investigating passive methods to quantify vehicle loading. The research described in this paper investigates multiple vehicle indicators including brake temperature, tire temperature, engine temperature, acceleration and deceleration rates, engine acoustics, suspension response, tire deformation and vibrational response. Our investigation into these variables includes building and implementing a sensing system for data collection as well as multiple full-scale vehicle tests. The sensing system includes; infrared video cameras, triaxial accelerometers, microphones, video cameras and thermocouples. The full scale testing includes both a medium size dump truck and a tractor-trailer truck on closed courses with loads spanning the full range of the vehicle's capacity. Statistical analysis of the collected data is used to determine the effectiveness of each of the indicators for characterizing the weight of a vehicle. The final sensing system will monitor multiple load indicators and combine the results to achieve a more accurate measurement than any of the indicators could provide alone.

Garrett, A.

2012-01-03T23:59:59.000Z

78

Electrical and Production Load Factors  

E-Print Network (OSTI)

Load factors are an important simplification of electrical energy use data and depend on the ratio of average demand to peak demand. Based on operating hours of a facility they serve as an important benchmarking tool for the industrial sector. The operating hours of small and medium sized manufacturing facilities are analyzed to identify the most common operating hour or shift work patterns. About 75% of manufacturing facilities fall into expected operating hour patterns with operating hours near 40, 80, 120 and 168 hours/week. Two types of load factors, electrical and production are computed for each shift classification within major industry categories in the U.S. The load factor based on monthly billing hours (ELF) increases with operating hours from about 0.4 for a nominal one shift operation, to about 0.7 for around-the-clock operation. On the other hand, the load factor based on production hours (PLF) shows an inverse trend, varying from about 1.4 for one shift operation to 0.7 for around-the-clock operation. When used as a diagnostic tool, if the PLF exceeds unity, then unnecessary energy consumption may be taking place. For plants operating at 40 hours per week, the ELF value was found to greater than the theoretical maximum, while the PLF value was greater than one, suggesting that these facilities may have significant energy usage outside production hours. The data for the PLF however, is more scattered for plants operating less than 80 hours per week, indicating that grouping PLF data based on operating hours may not be a reasonable approach to benchmarking energy use in industries. This analysis uses annual electricity consumption and demand along with operating hour data of manufacturing plants available in the U.S. Department of Energy’s Industrial Assessment Center (IAC) database. The annual values are used because more desirable monthly data are not available. Monthly data are preferred as they capture the load profile of the facility more accurately. The data there come from Industrial Assessment Centers which employ university engineering students, faculty and staff to perform energy assessments for small to medium-sized manufacturing plants. The nation-wide IAC program is sponsored by the U.S. Department of Energy.

Sen, Tapajyoti

2009-12-01T23:59:59.000Z

79

Independent review of estimated load reductions for PJM's small customer load response pilot project  

E-Print Network (OSTI)

of Estimated Load Reductions for PJM’s Small Customer Loadof Estimated Load Reductions for PJM’s Small Customer LoadResponse Pilot Project Prepared for PJM Interconnection, LLC

Heffner, G.; Moezzi, M.; Goldman, C.

2004-01-01T23:59:59.000Z

80

Automated fuel pin loading system  

DOE Patents (OSTI)

An automated loading system for nuclear reactor fuel elements utilizes a gravity feed conveyor which permits individual fuel pins to roll along a constrained path perpendicular to their respective lengths. The individual lengths of fuel cladding are directed onto movable transports, where they are aligned coaxially with the axes of associated handling equipment at appropriate production stations. Each fuel pin can be reciprocated axially and/or rotated about its axis as required during handling steps. The fuel pins are inserted as a batch prior to welding of end caps by one of two disclosed welding systems.

Christiansen, David W. (Kennewick, WA); Brown, William F. (West Richland, WA); Steffen, Jim M. (Richland, WA)

1985-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "loading front loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

High loading uranium fuel plate  

DOE Patents (OSTI)

Two embodiments of a high uranium fuel plate are disclosed which contain a meat comprising structured uranium compound confined between a pair of diffusion bonded ductile metal cladding plates uniformly covering the meat, the meat having a uniform high fuel loading comprising a content of uranium compound greater than about 45 Vol. % at a porosity not greater than about 10 Vol. %. In a first embodiment, the meat is a plurality of parallel wires of uranium compound. In a second embodiment, the meat is a dispersion compact containing uranium compound. The fuel plates are fabricated by a hot isostatic pressing process.

Wiencek, Thomas C. (Bolingbrook, IL); Domagala, Robert F. (Indian Head Park, IL); Thresh, Henry R. (Palos Heights, IL)

1990-01-01T23:59:59.000Z

82

Interruptible load control for Taiwan Power Company  

SciTech Connect

Load management is the planning and implementation of those utility activities designed to influence customer use of electricity in ways that will produce desired changes in the utility's load shape. Interruptible load program is an option of load management which provides incentive rate to customers to interrupt or reduce the power demand during the system peak period or emergency condition. Therefore, how to design a proper incentive rate is the most important issue in implementing this program. This paper describes three alternatives designed for the interruptible load program, one of which was activated by Taiwan Power Company (Taipower) and some preliminary results were obtained. The effect of the interruptible load to the system peak demand reduction and the change of daily load curve for large industrial customers were analyzed. This paper estimates the avoided cost and design more appropriate incentive rate structure for interruptible load program.

Chen, C.S.; Leu, J.T. (Dept. of Electrical Engineering, National Sun Yat-Sen Univ., Kaohsiung (TW))

1990-05-01T23:59:59.000Z

83

Loads on drillpipe during jarring operations  

Science Conference Proceedings (OSTI)

Jarring implies heavy loads on the drillstring. The highest load on the drillpipe before jarring is at the rig floor. This paper discusses loads on drillpipe before, under, and after jarring. The authors show that for most situations, the shock wave from the jar impact does not imply additional load on the drillpipe compared with static load. The theoretical results are confirmed by measurements of a jarring operation with stuck point at [approx] 1,200 m measured depth. Loads on the drillpipe can be a limited factor in jarring operations because fear of possible additional loads from jarring dynamics may restrict the trip force (overpull) on the jar. The main conclusion is that dynamic jar forces do not give additional loads on drillpipe. This information can be used to set an optimal trip force on the jar.

Aarrestad, T.V.; Kyllingstad, A.

1994-12-01T23:59:59.000Z

84

1994 Pacific Northwest Loads and Resources Study.  

Science Conference Proceedings (OSTI)

The 1994 Pacific Northwest Loads and Resources Study presented herein establishes a picture of how the agency is positioned today in its loads and resources balance. It is a snapshot of expected resource operation, contractual obligations, and rights. This study does not attempt to present or analyze future conservation or generation resource scenarios. What it does provide are base case assumptions from which scenarios encompassing a wide range of uncertainties about BPA`s future may be evaluated. The Loads and Resources Study is presented in two documents: (1) this summary of Federal system and Pacific Northwest region loads and resources and (2) a technical appendix detailing the loads and resources for each major Pacific Northwest generating utility. This analysis updates the 1993 Pacific Northwest Loads and Resources Study, published in December 1993. In this loads and resources study, resource availability is compared with a range of forecasted electricity consumption. The Federal system and regional analyses for medium load forecast are presented.

United States. Bonneville Power Administration.

1994-12-01T23:59:59.000Z

85

Plug Load Behavioral Change Demonstration Project  

SciTech Connect

This report documents the methods and results of a plug load study of the Environmental Protection Agency's Region 8 Headquarters in Denver, Colorado, conducted by the National Renewable Energy Laboratory. The study quantified the effect of mechanical and behavioral change approaches on plug load energy reduction and identified effective ways to reduce plug load energy. Load reduction approaches included automated energy management systems and behavioral change strategies.

Metzger, I.; Kandt, A.; VanGeet, O.

2011-08-01T23:59:59.000Z

86

Spinning reserve from hotel load response  

SciTech Connect

Even though preliminary tests were not conducted during times of highest system or hotel loading during the summer, they showed that hotel load can be curtailed by 22 to 37 percent depending on the outdoor temperature and time of day. Full response occurred in 12 to 60 seconds from when the system operator's command to shed load was issued and the load drop was very rapid. (author)

Kirby, Brendan; Kueck, John; Laughner, Theo; Morris, Keith

2008-12-15T23:59:59.000Z

87

Load Shape Library Version 1.0  

Science Conference Proceedings (OSTI)

The downloadable report details EPRI's efforts to develop a framework of a load database and web-accessible repository of end-use and whole-premise data for application to energy efficiency assessments. The tool provides access to the best available end-use load data and whole-premise data by sector, region and building type. Improved end-use load research data will benefit load forecasters, system planners, energy efficiency program managers and rate design analysts by facilitating integration ...

2013-02-12T23:59:59.000Z

88

Load Management - A Better Way  

E-Print Network (OSTI)

Ohio Edison Company serves about 800,000 customers in Ohio and Pennsylvania, making it one of the 20 largest electric utilities in the nation. The 'cost of service' concept has been basic to rate design throughout the history of the company, and is evident today as the demand related charges have escalated in recent rate cases reflecting the higher costs of installing new generating facilities at today's high construction and financing costs. This paper will describe one of the many applications of load management techniques which has enabled the company to shift well over 100,000 kilowatts of customer load from the on-peak period to the off-peak period in the last four to five years. This is helping delay the need for new plants and allows existing plants to be more fully utilized, resulting in lower costs to customers who use their electric service wisely and possibly lower rate increases in the future than would have been required otherwise.

Easley, J. F.

1982-01-01T23:59:59.000Z

89

Load Scheduling with Profile Information  

E-Print Network (OSTI)

Abstract Within the past five years, many manufactureshave added hardware performance counters to their microprocessors to generate profile data cheaply.Translating aggregate data such as basic block execution frequencies from the executable to the com-piler intermediate representation is fairly straightforward. In this paper, we show how to use Com-paq's DCPI tool to determine load latencies which are at a fine, instruction granularity and then usethem to provide fodder for improving instruction scheduling. We validate our heuristic for usingDCPI latency data to classify loads as hits and misses against simulation numbers, demonstratingthat we can gather correct latencies cheaply at runtime. We map our classification into the Multiflowcompiler's intermediate representation, and use a locality sensitive Balanced scheduling algorithm. Ourexperiments illustrate that our algorithm has the potential to improve run times by up to 10 % on a Com-paq Alpha when compared to Balanced scheduling, but that a variety of pitfalls make consistent im-provements difficult to attain. 1 Introduction In this paper, we explore how to use hardware per-formance counters to produce fine grain latency information to improve compiler scheduling. We usethis information to hide latencies with any avail\\Lambda The authors

unknown authors

1999-01-01T23:59:59.000Z

90

Glossary of terms related to load management  

Science Conference Proceedings (OSTI)

Part I of the Glossary of Terms related to Load Management has been prepared by the Terminology Task Force of the Load Management Subcommittee. The glossary contains many definitions of terms used by the electric utility industry concerning the subject of Load Management. The terms are listed in alphabetical order and cross-referenced where necessary.

Gellings, C.W.

1985-09-01T23:59:59.000Z

91

Properly Evaluating load-following products  

SciTech Connect

The authors briefly survey the jurisdictions where load-following products have been successfully used, examine the characteristics of the load-following products, and explain the shortcomings and inaccurate conclusions of previous analyses. A more thorough analysis reveals that the load-following products fulfill the public policy objectives for which they have been designed and do not adversely impact wholesale electricity markets.

Cavicchi, Joseph; Lemon, Andrew

2009-01-15T23:59:59.000Z

92

Adaptive load sharing for network processors  

Science Conference Proceedings (OSTI)

A novel scheme for processing packets in a router is presented that provides load sharing among multiple network processors distributed within the router. It is complemented by a feedback control mechanism designed to prevent processor overload. Incoming ... Keywords: computer networks, feedback control, load balancing, load sharing, packet processing, router architecture

Lukas Kencl; Jean-Yves Le Boudec

2008-04-01T23:59:59.000Z

93

Efficient real-time divisible load scheduling  

Science Conference Proceedings (OSTI)

Providing QoS and performance guarantees to arbitrarily divisible loads has become a significant problem for many cluster-based research computing facilities. While progress is being made in scheduling arbitrarily divisible loads, current approaches ... Keywords: Arbitrarily divisible loads, Cluster computing, Real-time computing, Scheduling efficiency

Anwar Mamat; Ying Lu; Jitender Deogun; Steve Goddard

2012-12-01T23:59:59.000Z

94

Domestic load scheduling using genetic algorithms  

Science Conference Proceedings (OSTI)

An approach using a genetic algorithm to optimize the scheduling of domestic electric loads, according to technical and user-defined constraints and input signals, is presented and illustrative results are shown. The aim is minimizing the end-user's ... Keywords: automated energy management, domestic load scheduling, electric loads, genetic algorithms

Ana Soares; Állvaro Gomes; Carlos Henggeler Antunes; Hugo Cardoso

2013-04-01T23:59:59.000Z

95

Neural-wavelet Methodology for Load Forecasting  

Science Conference Proceedings (OSTI)

Intelligent demand-side management represents a future trend of power system regulation. A key issue in intelligent demand-side management is accurate prediction of load within a local area grid (LAG), which is defined as a set of customers with an appropriate ... Keywords: load forecasting, load identification, neural-wavelet

Rong Gao; Lefteri H. Tsoukalas

2001-05-01T23:59:59.000Z

96

1993 Pacific Northwest Loads and Resources Study.  

SciTech Connect

The Loads and Resources Study is presented in three documents: (1) this summary of Federal system and Pacific Northwest region loads and resources; (2) a technical appendix detailing forecasted Pacific Northwest economic trends and loads, and (3) a technical appendix detailing the loads and resources for each major Pacific Northwest generating utility. In this loads and resources study, resource availability is compared with a range of forecasted electricity consumption. The forecasted future electricity demands -- firm loads -- are subtracted from the projected capability of existing and {open_quotes}contracted for{close_quotes} resources to determine whether Bonneville Power Administration (BPA) and the region will be surplus or deficit. If resources are greater than loads in any particular year or month, there is a surplus of energy and/or capacity, which BPA can sell to increase revenues. Conversely, if firm loads exceed available resources, there is a deficit of energy and/or capacity, and additional conservation, contract purchases, or generating resources will be needed to meet load growth. The Pacific Northwest Loads and Resources Study analyzes the Pacific Northwest`s projected loads and available generating resources in two parts: (1) the loads and resources of the Federal system, for which BPA is the marketing agency; and (2) the larger Pacific Northwest regional power system, which includes loads and resource in addition to the Federal system. The loads and resources analysis in this study simulates the operation of the power system under the Pacific Northwest Coordination Agreement (PNCA) produced by the Pacific Northwest Coordinating Group. This study presents the Federal system and regional analyses for five load forecasts: high, medium-high, medium, medium-low, and low. This analysis projects the yearly average energy consumption and resource availability for Operating Years (OY) 1994--95 through 2003--04.

United States. Bonneville Power Administration.

1993-12-01T23:59:59.000Z

97

Low cutter load raise head  

SciTech Connect

A raise head having a multiplicity of cutters for enlarging a pilot hole into a larger diameter hole by disintegrating the earth formations that surround the pilot hole is provided that will require lower cutter loads to penetrate the formations being bored by directing the rock fracture planes toward the pilot hole forcing the rock to yield with less input energy. The cutters are positioned on the raise head to provide an earth formation contact profile with a major portion of said earth formation contact profile extending outward and upward from said pilot hole. The included angle between the major portion of the earth formation contact profile and the axis of the pilot hole is less than 90/sup 0/.

Saxman, W.C.

1981-03-31T23:59:59.000Z

98

Kinesin's backsteps under mechanical load  

E-Print Network (OSTI)

Kinesins move processively toward the plus end of microtubules by hydrolyzing ATP for each step. From an enzymatic perspective, the mechanism of mechanical motion coupled to the nucleotide chemistry is often well explained using a single-loop cyclic reaction. However, several difficulties arise in interpreting kinesin's backstepping within this framework, especially when external forces oppose the motion of kinesin. We review evidence, such as an ATP-independent stall force and a slower cycle time for backsteps, that has emerged to challenge the idea that kinesin backstepping is due to ATP synthesis, i.e., the reverse cycle of kinesin's forward-stepping chemomechanics. Supplementing the conventional single-loop chemomechanics with routes for ATP-hydrolyzing backward steps and nucleotide-free steps, especially under load, gives a better physical interpretation of the experimental data on backsteps.

Changbong Hyeon; Stefan Klumpp; José N. Onuchic

2009-04-18T23:59:59.000Z

99

High payload six-axis load sensor  

DOE Patents (OSTI)

A repairable high-payload six-axis load sensor includes a table, a base, and at least three shear-pin load transducers removably mounted between the table and the base. Removable mounting permits easy replacement of damaged shear pins. Preferably, the shear-pin load transducers are responsive to shear forces imparted along the two axes perpendicular to an axis of minimum sensitivity characteristic of the transducer. Responsive to an applied shear force, each shear-pin load transducer can produce an electrical signal proportional to the reaction force. The load sensor can further include a structure for receiving the proportional electrical signals and computing the applied load corresponding to the proportional electrical signals. The computed load can be expressed in terms of a three-dimensional XYZ Cartesian coordinate system.

Jansen, John F. (Knoxville, TN); Lind, Randall F. (Knoxville, TN)

2003-01-01T23:59:59.000Z

100

Analysis Methodology for Industrial Load Profiles  

E-Print Network (OSTI)

A methodology is provided for evaluating the impact of various demand-side management (DSM) options on industrial customers. The basic approach uses customer metered load profile data as a basis for the customer load shape. DSM technologies are represented as load shapes and are used as a basis for altering the customers existing measured load shape. The impact of load shape changes on the customer is evaluated in terms of a change in the electric bill by using a software analytical tool called LOADEXPERT™. The software calculates the customer's bill for a particular rate structure and a given load shape. The output data from LOADEXPERT™ are used to calculate the rate of return on the DSM technology investment. Other uses of load profile data are provided.

Reddoch, T. W.

1991-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "loading front loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

A Novel Approach to Determining Motor Load  

E-Print Network (OSTI)

Properly sized electric motors are essential if industrial plant efficiency is to be optimized and energy costs minimized. Because of the difficulty in making power measurements on three phase motors, loading is rarely, if ever, checked. A simple indication of motor load can be achieved by measuring operating speed because speed and load are almost linearly related. The decrease in motor speed from no load conditions, referred to as slip, can be determined with a non-contact, optical tachometer. Field measurements of motor slip were conducted at a textile plant to quantify motor load conditions. To verify the relationship between operating speed and load, measurements of motor power consumption on a representative number of motors were also conducted. The results of the motor survey, including number of motors, size, and load, are summarized in this paper along with an estimate of the savings from replacing oversized motors.

Brown, M.

1992-04-01T23:59:59.000Z

102

Investigation of residential central air conditioning load shapes in NEMS  

E-Print Network (OSTI)

of Residential Central Air Conditioning Load Shapes in NEMSof Residential Central Air Conditioning Load Shapes in NEMSof Residential Central Air Conditioning Load Shapes in NEMS

Hamachi LaCommare, Kristina; Marnay, Chris; Gumerman, Etan; Chan, Peter; Rosenquist, Greg; Osborn, Julie

2002-01-01T23:59:59.000Z

103

Wind loading on solar collectors  

DOE Green Energy (OSTI)

The present design methodology for the determination of wind loading on the various solar collectors has been reviewed and assessed. The total force coefficients of flat plates of aspect ratios 1.0 and 3.0, respectively, at various angles of attack obtained by using the guidelines of the ANSI A58.1-1982, have been compared with those obtained by using the methodology of the ASCE Task Committee, 1961, and the experimental results of the full-scale test of heliostats by Peglow. The turbulent energy spectra, currently employed in the building code, are compared with those of Kaimal et al., Lumley, and Ponofsky for wind velocities of 20.0 m/s and 40.24 m/s at an elevation of 9.15 m. The longitudinal spectra of the building code overestimates the Kaimal spectra in the frequency range of 0.007 Hz to 0.08 Hz and underestimates beyond the frequency of 0.08 Hz. The peak angles of attack, on the heliostat, stowed in horizontal position, due to turbulent vertical and lateral components of wind velocity, have been estimated by using Daniel's methodology for three wind velocities and compared with the value suggested by the code. The experimental results of a simple test in the laboratory indicate the feasibility of decreasing the drag forces of the flat plate by reducing the solidity ratio.

Bhaduri, S.; Murphy, L.M.

1985-06-01T23:59:59.000Z

104

On Load Balancing in a Dense Wireless  

E-Print Network (OSTI)

We study the load balancing problem in a dense wireless multihop network, where a typical path consists of large number of hops, i.e., the spatial scales of a typical distance between source and destination, and mean distance between the neighbouring nodes are strongly separated. In this limit, we present a general framework for analysing the traffic load resulting from a given set of paths and traffic demands. We formulate the load balancing problem as a minmax problem and give two lower bounds for the achievable minimal maximum traffic load. The framework is illustrated by an example of uniformly distributed traffic demands in a unit disk with a few families of paths given in advance. With these paths we are able to decrease the maximum traffic load by factor of 33 40% depending on the assumptions. The obtained traffic load level also comes quite near the tightest lower bound.

Multihop Network Esa; Esa Hyytiä

2006-01-01T23:59:59.000Z

105

Profile Guided Load Marking for Memory Renaming  

E-Print Network (OSTI)

Memory operations remain a significant bottleneck in dynamically scheduled pipelined processors, due in part to the inability to statically determine the existence of memory address dependencies. Hardware memory renaming techniques have been proposed which predict which stores a load might be dependent upon. These prediction techniques can be used to speculatively forward a value from a predicted store dependency to a load through a value prediction table; however, these techniques require large and time-consuming hardware tables. In this paper we propose a software-guided approach for identifying dependencies between store and load instructions and the Load Marking (LM) architecture to communicate these dependencies to the hardware. Compiler analysis and profiles are used to find important store/load relationships, and these relationships are identified during execution via hints or an n-bit tag. For those loads that are not marked for renaming, we then use additional profiling inform...

Glenn Reinman; Brad Calder; Dean Tullsen; Gary Tyson; Todd Austin

1998-01-01T23:59:59.000Z

106

Assessment of Industrial-Sector Load Shapes  

Science Conference Proceedings (OSTI)

The load shapes of industrial-sector customers are becoming increasingly important for utility forecasting, marketing, and demand-side management planning and evaluation activities. This report analyzes load shapes for various industry segments and investigates the transfer of these load shapes across service territories. This report is available only to funders of Program 101A or 101.001. Funders may download this report at http://my.primen.com/Applications/DE/Community/index.asp .

1993-02-18T23:59:59.000Z

107

Trends in electric utility load duration curves  

SciTech Connect

This report documents the development and analysis of annual and quarterly load duration curves for each of the 10 Federal regions. The report describes analyses performed to test for changes in load duration curve shapes over time. These analyses are intended to aid the electric utility analyses and modeling activities of the Energy Information Administration (EIA) by expanding the understanding of current and expected load duration curve shapes. 7 figs., 13 tabs.

1984-12-01T23:59:59.000Z

108

Loads, capacity, and failure rate modeling  

SciTech Connect

Both failure rate and load capacity (stress-strength) interferenece methodologies are employed in the reliability analysis at nuclear facilities. Both of the above have been utilized in a heuristic failure rate model in terms of load capacity inference. Analytical solutions are used to demonstrate that infant mortality and random aging failures may be expressed implicity in terms of capacity variability, load variability, and capacity deterioration, and that mode interactions play a role in the formation of the bathtub curve for failure rates.

Lewis, E.E.; Chen, Hsin-Chieh

1994-12-31T23:59:59.000Z

109

1991 Pacific Northwest Loads and Resources Study.  

SciTech Connect

This study establishes the Bonneville Power Administration's (BPA) planning basis for supplying electricity to BPA customers. The Loads and Resources Study is presented in three documents: (1) this summary of federal system and Pacific Northwest region loads and resources; (2) a technical appendix detailing forecasted Pacific Northwest economic trends and loads, and (3) a technical appendix detailing the loads and resources for each major Pacific Northwest generating utility. This analysis updates our 1990 study. BPS's long-range planning incorporates resource availability with a range of forecasted electrical consumption. The forecasted future electrical demands-firm loads--are subtracted from the projected capability of existing resources to determine whether BPA and the region will be surplus or deficit. If resources are greater than loads in any particular year or month, there is a surplus of energy and/or capacity, which BPA can sell to increase revenues. Conversely, if firm loads exceed available resources, there is a deficit of energy and/or capacity, then additional conservation, contract purchases, or generating resources will be needed to meet load growth. This study analyzes the Pacific Northwest's projected loads and available generating resources in two parts: (1) the loads and resources of the federal system, for which BPA is the marketing agency; and (2) the larger Pacific Northwest regional profile, which includes loads and resources in addition to the federal system. This study presents the federal system and regional analyses for five load forecasts: high, medium-high, medium, medium-low, and low. This analysis projects the yearly average energy consumption and resource availability for 1992- 2012.

United States. Bonneville Power Administration.

1991-12-01T23:59:59.000Z

110

Reservoir compaction loads on casings and liners  

Science Conference Proceedings (OSTI)

Pressure drawdown due to production from a reservoir causes compaction of the reservoir formation which induces axial and radial loads on the wellbore. Reservoir compaction loads increase during the production life of a well, and are greater for deviated wells. Presented here are casing and liner loads at initial and final pressure drawdowns for a particular reservoir and at well deviation angles of 0 to 45 degrees.

Wooley, G.R.; Prachner, W.

1984-09-01T23:59:59.000Z

111

NORMAL LOAD BEARING BY SITE SPECIFIC CANISTER  

Science Conference Proceedings (OSTI)

The overall purpose of this calculation is to perform a preliminary analysis of the Site Specific Canister/Basket, subject to static gravity loads that include the self weight of the Canister Shell, the Basket, the Spent Nuclear Fuel, the Shield Plug and the related hardware, so that the loads are approximately known for sizing purposes. Based on these loads the stress levels in various components of the Site Specific Canister/Basket are evaluated.

NA

2005-03-23T23:59:59.000Z

112

Measured Peak Equipment Loads in Laboratories  

SciTech Connect

This technical bulletin documents measured peak equipment load data from 39 laboratory spaces in nine buildings across five institutions. The purpose of these measurements was to obtain data on the actual peak loads in laboratories, which can be used to rightsize the design of HVAC systems in new laboratories. While any given laboratory may have unique loads and other design considerations, these results may be used as a 'sanity check' for design assumptions.

Mathew, Paul A.

2007-09-12T23:59:59.000Z

113

Load relaxation studies of zircaloy-4  

SciTech Connect

The results of the present work have shown (1) the load relaxation data of Zircaloy-4 in the temperature range of 200/sup 0/C to 385/sup 0/C can be represented by the phenomenological model based on Hart's plastic equation of state; (2) the room temperature load relaxation data reflect the effects of deformation twinning; (3) at higher temperatures the load relaxation data suggest the contribution of grain boundary sliding; and (4) the effects of strain aging can be identified based on the load relaxation data.

Huang, F.H.; Sabol, G.P.; McDonald, S.G.; Li, C.Y.

1976-01-01T23:59:59.000Z

114

OpenEI Community - load profile  

Open Energy Info (EERE)

/0 en Commercial and /0 en Commercial and Residential Hourly Load Data Now Available on OpenEI! http://en.openei.org/community/blog/commercial-and-residential-hourly-load-data-now-available-openei <span class=Load data" src="http://en.openei.org/community/files/load_data_figure_small.jpg" style="width:527px; height:285px" title="" />Image source: NREL 

Files: 
application/zip icon

115

NREL: Vehicle Ancillary Loads Reduction - Laboratory Capabilities  

NLE Websites -- All DOE Office Websites (Extended Search)

VALR Lab. NREL's Vehicle Ancillary Loads Reduction Laboratory houses ADAM, our advanced thermal manikin, as well as a passenger compartment climate simulator, testing equipment...

116

Building Energy Software Tools Directory: Load Express  

NLE Websites -- All DOE Office Websites (Extended Search)

Create project files with Load Express in just 4 easy steps. Select a weather profile, enter simulation parameters, define the zonesrooms in the building and create air handler...

117

Effect of Nonproportional Loadings on Ductile Fracture  

Science Conference Proceedings (OSTI)

Abstract Scope, This study aims at understanding the effects of load path ... D-2: Forging of Magnesium Alloy by Impulsive Energy at Room Temperature.

118

Thermoplastic Flour Containing Eugenol-loaded Chitosan ...  

Science Conference Proceedings (OSTI)

Presentation Title, Thermoplastic Flour Containing Eugenol-loaded Chitosan ... Properties of AA 7075 Reinforced with Nanometric ZrO2 Obtained by Ball-milling.

119

Building Energy Software Tools Directory : HVAC Residential Load...  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC Residential Load Calcs HD for the iPad Back to Tool HVAC Residential Load Calcs HD screenshot HVAC Residential Load Calcs HD screenshot HVAC Residential Load Calcs HD...

120

Methods for Analyzing Electric Load Shape and its Variability  

E-Print Network (OSTI)

15 Figure 12: Load profile by day of week, averaged over thebetween the average load profile and the profile of a givenfrom the average load profile. Figure 12: Load profile by

Price, Philip

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "loading front loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Decentralized agent-based underfrequency load shedding  

Science Conference Proceedings (OSTI)

As part of the transition to a smart grid efforts are being made to decentralize control of electric power systems and modernize protection schemes that are currently in use. One specific application of distributed control is underfrequency load shedding ... Keywords: UFLS, Underfrequency load shedding, intelligent agents

Sara Mullen; Getiria Onsongo

2010-12-01T23:59:59.000Z

122

Design Ground Snow Loads for Ohio  

Science Conference Proceedings (OSTI)

The weight of snow with a mean recurrence interval of 50 years, called the design ground snow load, is used by engineers and planners to estimate the weight of snow that roofs must be designed to support National maps of ground snow load have ...

Thomas W. Schmidlin; Dennis J. Edgell; Molly A. Delaney

1992-06-01T23:59:59.000Z

123

Apparatus for loading a band saw blade  

DOE Patents (OSTI)

A band saw blade is loaded between pairs of guide wheels upon tensioning the blade by guiding the blade between pairs of spaced guide plates which define converging slots that converge toward the guide wheels. The approach is particularly useful in loading blades on underwater band saw machines used to cut radioactive materials. 2 figs.

Reeves, S.R.

1990-03-20T23:59:59.000Z

124

Protecting consumer privacy from electric load monitoring  

Science Conference Proceedings (OSTI)

The smart grid introduces concerns for the loss of consumer privacy; recently deployed smart meters retain and distribute highly accurate profiles of home energy use. These profiles can be mined by Non Intrusive Load Monitors (NILMs) to expose much of ... Keywords: load monitor, privacy, smart meter

Stephen McLaughlin; Patrick McDaniel; William Aiello

2011-10-01T23:59:59.000Z

125

Quantifying the effectiveness of load balance algorithms  

Science Conference Proceedings (OSTI)

Load balance is critical for performance in large parallel applications. An imbalance on today's fastest supercomputers can force hundreds of thousands of cores to idle, and on future exascale machines this cost will increase by over a factor of a thousand. ... Keywords: framework, load balance, modeling, performance, simulation

Olga Pearce; Todd Gamblin; Bronis R. de Supinski; Martin Schulz; Nancy M. Amato

2012-06-01T23:59:59.000Z

126

Household type load's effects on photovoltaic systems  

Science Conference Proceedings (OSTI)

The solar energy is one of the most important energy sources available because, besides the fact that it is not polluting the environment and it helps to the reduction of green house effect, it is free of charge and it can be easily converted to other ... Keywords: A.C. loads, D.C. loads, compact fluorescent lamp, photovoltaic system, power LED

Nazmi Ekren; Nevzat Onat; Safak Saglam

2008-12-01T23:59:59.000Z

127

Load Modeling Using a Measurement Based Approach  

Science Conference Proceedings (OSTI)

This report summarizes the work performed in the second phase of a multi-year collaborative load modeling research program that was initiated in 2004. The measurement based approach described in this report will help utilities to develop representative load models using suitable measurement data.

2007-12-17T23:59:59.000Z

128

Apparatus for loading a band saw blade  

DOE Patents (OSTI)

A band saw blade is loaded between pairs of guide wheels upon tensioning the blade by guiding the blade between pairs of spaced guide plates which define converging slots that converge toward the guide wheels. The approach is particularly useful in loading blades on underwater band saw machines used to cut radioactive materials.

Reeves, Steven R. (49 Williams Ave., West Valley, NY 14171)

1990-01-01T23:59:59.000Z

129

The Promise of Load Balancing the Parameterization of Moist Convection Using a Model Data Load Index  

Science Conference Proceedings (OSTI)

The parameterization of physical processes in atmospheric general circulation models contributes to load imbalances among individual processors of message-passing distributed-multiprocessor systems. Load imbalances increase the overall time to ...

S. P. Muszala; D. A. Connors; J. J. Hack; G. Alaghband

2006-04-01T23:59:59.000Z

130

Estimating Demand Response Load Impacts: Evaluation of Baseline Load Models for Non-  

E-Print Network (OSTI)

, and the Office of Electricity Delivery and Energy Reliability, Permitting, Siting and Analysis of the ULBNL-63728 Estimating Demand Response Load Impacts: Evaluation of Baseline Load Models for Non .............................................................................................................. 9 4. Baseline Profile (BLP) Models

131

Independent review of estimated load reductions for PJM's small customer load response pilot project  

E-Print Network (OSTI)

Abbreviations ADDF ALM AMR CSP DOE DR ELRP ETS EWH FERC HVa Curtailment Service Provider (CSP) at PJM’s request. LBNLof load control tests. The CSP collected hourly load data

Heffner, G.; Moezzi, M.; Goldman, C.

2004-01-01T23:59:59.000Z

132

Combi Systems for Low Load homes  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

text styles text styles Combi Systems for Low Load Homes Center for Energy and Environment, NorthernSTAR, Ben Schoenbauer * Low load homes are more common than ever. * Typical space heating and DHW equipment have capacities larger than necessary * A single heating plant could provide high efficiency heat at lower costs, increased durability and improved combustion safety Context Technical Approach * A condensing water heater and hydronic air handler will used to provide space and water heating loads in almost 300 weatherized homes. * System specifications, sizing, and installation optimization guidelines were all developed. * Contractor capability was developed in MN market, but may not be developed in all local. 4 Recommended Guidance * Determine peak load on system: - Space heating design load (ie 40,000 Btu/hr)

133

Plug Load Energy Analysis: The Role of Plug Loads in LEED Certification  

E-Print Network (OSTI)

benchmark and is bound to change as the proportion of plug load energy use grows in commercial buildings.

Fuertes, Gwen; Schiavon, Stefano

2013-01-01T23:59:59.000Z

134

Combustion Impacts of Flexible Operation: Low Load, Load Following, and Increased Staging Impact on Boiler Tubes  

Science Conference Proceedings (OSTI)

Over the past few years, coal-fired generating units have changed from stable base load operation to flexible operation, including periods of prolonged low-load operation. These changes in operation can have various adverse effects on all plant equipment, particularly in older units and may impact their ability to operate without tube failures due to elevated levels of fireside corrosion and circumferential cracking. This report discusses the combustion-related impacts of low-load, load-following, ...

2013-12-23T23:59:59.000Z

135

Using Utility Load Data to Estimate Demand for Space Cooling and Potential for Shiftable Loads  

SciTech Connect

This paper describes a simple method to estimate hourly cooling demand from historical utility load data. It compares total hourly demand to demand on cool days and compares these estimates of total cooling demand to previous regional and national estimates. Load profiles generated from this method may be used to estimate the potential for aggregated demand response or load shifting via cold storage.

Denholm, P.; Ong, S.; Booten, C.

2012-05-01T23:59:59.000Z

136

An Analysis of Load Balancing Technology - Comparing LSF with other Load Balancing Software Packages  

E-Print Network (OSTI)

This paper examines what the load balancing needs of organizations are today, the solution LSF (Load Sharing Facility) provides for them, and how other currently available load balancing products compare to LSF. Jean Suplick (suplick@cxsoft.convex.com) CXSOFT Richardson, Texas January 1994 Why clusters?

Jean Suplick

1994-01-01T23:59:59.000Z

137

An Evaluation of the HVAC Load Potential for Providing Load Balancing Service  

Science Conference Proceedings (OSTI)

This paper investigates the potential of providing aggregated intra-hour load balancing services using heating, ventilating, and air-conditioning (HVAC) systems. A direct-load control algorithm is presented. A temperature-priority-list method is used to dispatch the HVAC loads optimally to maintain consumer-desired indoor temperatures and load diversity. Realistic intra-hour load balancing signals were used to evaluate the operational characteristics of the HVAC load under different outdoor temperature profiles and different indoor temperature settings. The number of HVAC units needed is also investigated. Modeling results suggest that the number of HVACs needed to provide a {+-}1-MW load balancing service 24 hours a day varies significantly with baseline settings, high and low temperature settings, and the outdoor temperatures. The results demonstrate that the intra-hour load balancing service provided by HVAC loads meet the performance requirements and can become a major source of revenue for load-serving entities where the smart grid infrastructure enables direct load control over the HAVC loads.

Lu, Ning

2012-09-30T23:59:59.000Z

138

Variability of Load and Net Load in Case of Large Scale Distributed Wind Power  

Science Conference Proceedings (OSTI)

Large scale wind power production and its variability is one of the major inputs to wind integration studies. This paper analyses measured data from large scale wind power production. Comparisons of variability are made across several variables: time scale (10-60 minute ramp rates), number of wind farms, and simulated vs. modeled data. Ramp rates for Wind power production, Load (total system load) and Net load (load minus wind power production) demonstrate how wind power increases the net load variability. Wind power will also change the timing of daily ramps.

Holttinen, H.; Kiviluoma, J.; Estanqueiro, A.; Gomez-Lazaro, E.; Rawn, B.; Dobschinski, J.; Meibom, P.; Lannoye, E.; Aigner, T.; Wan, Y. H.; Milligan, M.

2011-01-01T23:59:59.000Z

139

Dehumidification and cooling loads from ventilation air  

SciTech Connect

The importance of controlling humidity in buildings is cause for concern, in part, because of indoor air quality problems associated with excess moisture in air-conditioning systems. But more universally, the need for ventilation air has forced HVAC equipment (originally optimized for high efficiency in removing sensible heat loads) to remove high moisture loads. To assist cooling equipment and meet the challenge of larger ventilation loads, several technologies have succeeded in commercial buildings. Newer technologies such as subcool/reheat and heat pipe reheat show promise. These increase latent capacity of cooling-based systems by reducing their sensible capacity. Also, desiccant wheels have traditionally provided deeper-drying capacity by using thermal energy in place of electrical power to remove the latent load. Regardless of what mix of technologies is best for a particular application, there is a need for a more effective way of thinking about the cooling loads created by ventilation air. It is clear from the literature that all-too-frequently, HVAC systems do not perform well unless the ventilation air loads have been effectively addressed at the original design stage. This article proposes an engineering shorthand, an annual load index for ventilation air. This index will aid in the complex process of improving the ability of HVAC systems to deal efficiently with the amount of fresh air the industry has deemed useful for maintaining comfort in buildings. Examination of typical behavior of weather shows that latent loads usually exceed sensible loads in ventilation air by at least 3:1 and often as much as 8:1. A designer can use the engineering shorthand indexes presented to quickly assess the importance of this fact for a given system design. To size those components after they are selected, the designer can refer to Chapter 24 of the 1997 ASHRAE Handbook--Fundamentals, which includes separate values for peak moisture and peak temperature.

Harriman, L.G. III [Mason-Grant, Portsmouth, NH (United States); Plager, D. [Quantitative Decision Support, Portsmouth, NH (United States); Kosar, D. [Gas Research Inst., Chicago, IL (United States)

1997-11-01T23:59:59.000Z

140

Automatic Detection of Unsafe Component Loadings  

E-Print Network (OSTI)

Dynamic loading of software components (e.g., libraries or modules) is a widely used mechanism for improved system modularity and flexibility. Correct component resolution is critical for reliable and secure software execution, however, programming mistakes may lead to unintended or even malicious components to be resolved and loaded. In particular, dynamic loading can be hijacked by placing an arbitrary file with the specified name in a directory searched before resolving the target component. Although this issue has been known for quite some time, it was not considered serious because exploiting it requires access to the local file system on the vulnerable host. Recently such vulnerabilities started to receive considerable attention as their remote exploitation became realistic; it is now important to detect and fix these vulnerabilities. In this paper, we present the first automated technique to detect vulnerable and unsafe dynamic component loadings. Our analysis has two phases: 1) apply dynamic binary instrumentation to collect runtime information on component loading (online phase); and 2) analyze the collected information to detect vulnerable component loadings (offline phase). For evaluation, we implemented our technique to detect vulnerable and unsafe DLL loadings in popular Microsoft Windows software. Our results show that unsafe DLL loading is prevalent and can lead to serious security threats. Our tool detected more than 1,700 unsafe DLL loadings in 28 widely used software and discovered serious attack vectors for remote code execution. Microsoft has opened a Microsoft Security Response Center (MSRC) case on our reported issues and is working with us and other affected software vendors to develop necessary patches.

Taeho Kwon; Zhendong Su

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "loading front loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Load Data Analysis and PowerShape Training: Strategic Load Research and Advanced Topics in Load Profiling for Settlements  

Science Conference Proceedings (OSTI)

Load shapes, representing usage patterns in the electric and gas industry, are a key factor in energy company operations and management. In the emerging restructured energy market, retail energy suppliers market energy to final customers and must arrange for electricity generation or gas delivery to meet their customers' needs. EPRI and Primen sponsored a workshop in September 2000 that addressed a range of issues associated with load shapes, including modeling, profiling for retail market settlement, re...

2000-12-20T23:59:59.000Z

142

Space cooling demands from office plug loads  

Science Conference Proceedings (OSTI)

Undersizing space cooling systems for office buildings can result in uncomfortable and angry tenants on peak cooling days. However, oversizing wastes money because more capacity is installed than is needed, and oversized systems have a lower energy efficiency which makes operating costs higher than necessary. Oversizing can adversely affect comfort as well, because oversized systems may provide poor humidity control and large temperature variations. Correct system sizing requires estimating building heat loads accurately. This paper discusses the heat load generated by the plug load, which includes any electrical equipment that is plugged into outlets.

Komor, P.

1997-12-01T23:59:59.000Z

143

Definition: Native Load | Open Energy Information  

Open Energy Info (EERE)

Terms Load-Serving Entity References Glossary of Terms Used in Reliability Standards An LikeLike UnlikeLike You like this.Sign Up to see what your friends like. inline...

144

Definition: Base Load | Open Energy Information  

Open Energy Info (EERE)

Load Load Jump to: navigation, search Dictionary.png Base Load The minimum amount of electric power delivered or required over a given period at a constant rate.[1] View on Wikipedia Wikipedia Definition Baseload (also base load, or baseload demand) is the minimum amount of power that a utility or distribution company must make available to its customers, or the amount of power required to meet minimum demands based on reasonable expectations of customer requirements. Baseload values typically vary from hour to hour in most commercial and industrial areas. Related Terms electricity generation, power, smart grid References ↑ Glossary of Terms Used in Reliability Standards An in Like Like You like this.Sign Up to see what your friends like. line Glossary Definition Retrieved from

145

Modeling and control of thermostatically controlled loads  

SciTech Connect

As the penetration of intermittent energy sources grows substantially, loads will be required to play an increasingly important role in compensating the fast time-scale fluctuations in generated power. Recent numerical modeling of thermostatically controlled loads (TCLs) has demonstrated that such load following is feasible, but analytical models that satisfactorily quantify the aggregate power consumption of a group of TCLs are desired to enable controller design. We develop such a model for the aggregate power response of a homogeneous population of TCLs to uniform variation of all TCL setpoints. A linearized model of the response is derived, and a linear quadratic regulator (LQR) has been designed. Using the TCL setpoint as the control input, the LQR enables aggregate power to track reference signals that exhibit step, ramp and sinusoidal variations. Although much of the work assumes a homogeneous population of TCLs with deterministic dynamics, we also propose a method for probing the dynamics of systems where load characteristics are not well known.

Backhaus, Scott N [Los Alamos National Laboratory; Sinitsyn, Nikolai [Los Alamos National Laboratory; Kundu, S. [UNIV OF MICHIGAN; Hiskens, I. [UNIV OF MICHIGAN

2011-01-04T23:59:59.000Z

146

Impact of load type on microgrid stability  

E-Print Network (OSTI)

Microgrids show great promise as a means of integrating distributed generation sources into the public grid distribution system. In order to provide uninterrupted,high quality power to local loads, microgrids must have the ...

Monnin, Jared P

2012-01-01T23:59:59.000Z

147

High density load bearing insulation peg  

DOE Patents (OSTI)

A high density peg is disclosed which can support a large load and exhibits excellent thermal resistance produced by a method wherein the peg is made in compliance with specified conditions of time, temperature and pressure. 4 figs.

Nowobilski, J.J.; Owens, W.J.

1985-01-29T23:59:59.000Z

148

Passive load control for large wind turbines.  

DOE Green Energy (OSTI)

Wind energy research activities at Sandia National Laboratories focus on developing large rotors that are lighter and more cost-effective than those designed with current technologies. Because gravity scales as the cube of the blade length, gravity loads become a constraining design factor for very large blades. Efforts to passively reduce turbulent loading has shown significant potential to reduce blade weight and capture more energy. Research in passive load reduction for wind turbines began at Sandia in the late 1990's and has moved from analytical studies to blade applications. This paper discusses the test results of two Sandia prototype research blades that incorporate load reduction techniques. The TX-100 is a 9-m long blade that induces bend-twist coupling with the use of off-axis carbon in the skin. The STAR blade is a 27-m long blade that induces bend-twist coupling by sweeping the blade in a geometric fashion.

Ashwill, Thomas D.

2010-05-01T23:59:59.000Z

149

S-Band Loads for SLAC Linac  

SciTech Connect

The S-Band loads on the current SLAC linac RF system were designed, in some cases, 40+ years ago to terminate 2-3 MW peak power into a thin layer of coated Kanthal material as the high power absorber [1]. The technology of the load design was based on a flame-sprayed Kanthal wire method onto a base material. During SLAC linac upgrades, the 24 MW peak klystrons were replaced by 5045 klystrons with 65+ MW peak output power. Additionally, SLED cavities were introduced and as a result, the peak power in the current RF setup has increased up to 240 MW peak. The problem of reliable RF peak power termination and RF load lifetime required a careful study and adequate solution. Results of our studies and three designs of S-Band RF load for the present SLAC RF linac system is discussed. These designs are based on the use of low conductivity materials.

Krasnykh, A.; Decker, F.-J.; /SLAC; LeClair, R.; /INTA Technologies, Santa Clara

2012-08-28T23:59:59.000Z

150

High density load bearing insulation peg  

DOE Patents (OSTI)

A high density peg which can support a large load and exhibits excellent thermal resistance produced by a method wherein the peg is made in compliance with specified conditions of time, temperature and pressure.

Nowobilski, Jeffert J. (Orchard Park, NY); Owens, William J. (Kenmore, NY)

1985-01-01T23:59:59.000Z

151

Peak Load Shifting by Thermal Energy Storage  

Science Conference Proceedings (OSTI)

This technical update from the Electric Power Research Institute (EPRI) reviews the technology of storing energy in hot water and explores the potential for implementing this form of thermal energy storagethrough means of smart electric water heatersas a way to shift peak load on the electric grid. The report presents conceptual background, discusses strategies for peak load shifting and demand response, documents a series of laboratory tests conducted on a representative model of smart water heater, and...

2011-12-14T23:59:59.000Z

152

Gearbox Reliability Collaborative (GRC) Description and Loading  

SciTech Connect

This document describes simulated turbine load cases in accordance to the IEC 61400-1 Ed.3 standard, which is representative of the typical wind turbine design process. The information presented herein is intended to provide a broad understanding of the gearbox reliability collaborative 750kW drivetrain and turbine configuration. In addition, fatigue and ultimate strength drivetrain loads resulting from simulations are presented. This information provides the bases for the analytical work of the gearbox reliability collaborative effort.

Oyague, F.

2011-11-01T23:59:59.000Z

153

Load apparatus and method for bolt-loaded compact tension test specimen  

DOE Patents (OSTI)

A bolt-loaded compact tension test specimen load apparatus includes: a) a body having first and second opposing longitudinal ends, the first end comprising an externally threaded portion sized to be threadedly received within the test specimen threaded opening; b) a longitudinal loading rod having first and second opposing longitudinal ends, the loading rod being slidably received in a longitudinal direction within the body internally through the externally threaded portion and slidably extending longitudinally outward of the body first longitudinal end; c) a force sensitive transducer slidably received within the body and positioned to engage relative to the loading rod second longitudinal end; and d) a loading bolt threadedly received relative to the body, the loading bolt having a bearing end surface and being positioned to bear against the transducer to forcibly sandwich the transducer between the loading bolt and loading rod. Also disclosed is a method of in situ determining applied force during crack propagation in a bolt-loaded compact tension test specimen.

Buescher, Jr., Brent J. (Idaho Falls, ID); Lloyd, W. Randolph (Idaho Falls, ID); Ward, Michael B. (Idaho Falls, ID); Epstein, Jonathan S. (Idaho Falls, ID)

1997-01-01T23:59:59.000Z

154

Review: Stability of nonlinear masonry members under combined load  

Science Conference Proceedings (OSTI)

Under examination is the post buckling of unreinforced load-bearing masonry walls or piers subject to a combined load consisting of a uniformly distributed axial load and a concentrated eccentric load at the top end. Fixed free-ended prismatic columns ... Keywords: Brick walls, Combined load, Instability, Masonry, No-tension material, Nonlinear constitutive law

Igino Mura

2008-08-01T23:59:59.000Z

155

Conditional model of peak and minimum loads and the load duration curve for electricity  

SciTech Connect

This report presents a model that extends the traditional model of electricity demand to account for intra-period load variation, the kind of variation that is important for evaluating marginal-cost-reflecting price structures. The time-of-day rate is one such price structure. The traditional model of electricity demand explains inter-period demand variation. It says nothing about load variation. The report explains how a model that integrates with previous studies of electricity demand might be formulated. It specifies two concrete models within this framework and estimates them for a number of different utility companies. The model's within-sample-period performance in predicting peak loads is presented for one version of the model extension along with estimations for other variations. In addition a number of plots of actual load distributions, a summation of load variation information, against the actual load distributions, are presented and used to evaluate the performance of specific models.

Trimble, J.L.; Stallings, D.E.; Thomas, B.

1980-05-01T23:59:59.000Z

156

Modelling off Hugoniot Loading Using Ramp Compression in Single Crystal Copper  

SciTech Connect

The application of a ramp load to a sample is a method by which the thermodynamic variables of the high pressure state can be controlled. The faster the loading rate, the higher the entropy and higher the temperature. This paper describes moleculer dynamics (MD) simulations with 25 million atoms which investigate ramp loading of single crystal copper. The simulations followed the propagation of a 300ps ramp load to 3Mbar along the [100] direction copper. The simulations were long enough to allow the wave front to steepen into a shock, at which point the simulated copper sample shock melted.

Hawreliak, J; Remington, B A; Lorenzana, H; Bringa, E; Wark, J

2010-11-29T23:59:59.000Z

157

Harmonic approaches to non-intrusive load diagnostics  

E-Print Network (OSTI)

The Non-Intrusive Load Monitor (NILM) is a system that monitors, records and processes voltage and current measurements to establish the operating characteristics of individual loads on a load center from a single aggregate ...

Fuller, Ashley E. (Ashley Eliot)

2008-01-01T23:59:59.000Z

158

Building Energy Software Tools Directory: HVAC Residential Load...  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC Residential Load Calcs HD for the iPad Carmel Software logo HVAC Residential Load Calcs HD is a comprehensive HVAC heating and cooling load calculation application for the...

159

IMPROVEMENTS TO THE RADIANT TIME SERIES METHOD COOLING LOAD CALCULATION  

E-Print Network (OSTI)

IMPROVEMENTS TO THE RADIANT TIME SERIES METHOD COOLING LOAD CALCULATION PROCEDURE By BEREKET TO THE RADIANT TIME SERIES METHOD COOLING LOAD CALCULATION PROCEDURE Dissertation Approved: Dr. Jeffrey D- Original RTSM.......................................................153 4.4.1 RTSM Peak Design Cooling Load

160

Direct versus Facility Centric Load Control for Automated Demand Response  

E-Print Network (OSTI)

actions to influence load profiles of their customers atISO needs to influence the load profile of a Facility arebe a specific target load profile to be achieved while in

Piette, Mary Ann

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "loading front loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Property Models for High Waste Loaded Hanford HLW Glasses  

High Waste Loading Was Shown for Selected Wastes Examples of the high loaded glasses Al 2O 3 loadings in the 24-26 wt% range compared to <15% for a

162

How and why distribution loads vary  

SciTech Connect

Because the maximum-use rates of gas customers having differing appliance combinations do not coincide, a distribution system's peak-hour flow rate depends on the relative proportions of the load contributed by the appliances of all the different types of residential, commercial, and industrial customers. The maximum load on Central Hudson's distribution system coincides with the maximum hourly gas flow rate for all residential space-heating purposes; however, Central Hudson analyzes the peak-hour load of its commercial and industrial customers individually. The gas-system sendout presented as a sendout-duration curve is a convenient way to show how these various loads determine gas requirements and to compare the economics of alternative supply methods. The sendout-duration curve consists of long-term weather data plotted against time intervals of 1-365 days. If the threshold temperature and the heating load per degree-day are known, the curve allows the calculation of both normal and design annual peakshaving quantities.

Haber, D.P.

1980-01-01T23:59:59.000Z

163

Status of load management storage demonstrations  

DOE Green Energy (OSTI)

DOE is funding a nationwide demonstration of electric load management through the use of utility-controlled, customer-side thermal energy storage for residential space conditioning. The general concept of the projects was developed with the assistance of a broadly based working group drawn from the utility industry. This paper presents the current status of these demonstrations. Ten demonstrations are underway - five heat storage and five cool storage - using between 30 and 50 near-commercial thermal storage devices. The installations and experimental program are designed to: (1) collect reliable load research data for assessing the impact on the utility system; (2) delineate and solve installation problems; (3) establish maintainability; (4) illuminate customer and utility acceptance; and (5) generate cost data. The results obtained are expected to assist utilities in making local load-management decisions, to assist DOE in establishing priorities for R and D efforts in load management, and to provide objective information related to the electric system impact, energy conservation, and cost-effectiveness of this form of load management.

Long, H M; Mohre, D L

1979-01-01T23:59:59.000Z

164

A practical approach for electricity load forecasting  

E-Print Network (OSTI)

Abstract—This paper is a continuation of our daily energy peak load forecasting approach using our modified network which is part of the recurrent networks family and is called feed forward and feed back multi context artificial neural network (FFFB-MCANN). The inputs to the network were exogenous variables such as the previous and current change in the weather components, the previous and current status of the day and endogenous variables such as the past change in the loads. Endogenous variable such as the current change in the loads were used on the network output. Experiment shows that using endogenous and exogenous variables as inputs to the FFFB-MCANN rather than either exogenous or endogenous variables as inputs to the same network produces better results. Experiments show that using the change in variables such as weather components and the change in the past load as inputs to the FFFB-MCANN rather than the absolute values for the weather components and past load as inputs to the same network has a dramatic impact and produce better accuracy.

T. Rashid; T. Kechadi

2005-01-01T23:59:59.000Z

165

Load cell having strain gauges of arbitrary location  

DOE Patents (OSTI)

A load cell utilizes a plurality of strain gauges mounted upon the load cell body such that there are six independent load-strain relations. Load is determined by applying the inverse of a load-strain sensitivity matrix to a measured strain vector. The sensitivity matrix is determined by performing a multivariate regression technique on a set of known loads correlated to the resulting strains. Temperature compensation is achieved by configuring the strain gauges as co-located orthogonal pairs.

Spletzer, Barry (Albuquerque, NM)

2007-03-13T23:59:59.000Z

166

A comparison of measured wind park load histories with the WISPER and WISPERX load spectra  

DOE Green Energy (OSTI)

The blade-loading histories from two adjacent Micon 65/13 wind turbines are compared with the variable-amplitude test-loading histories known as the WISPER and WISPERX spectra. These standardized loading sequences were developed from blade flapwise load histories taken from nine different horizontal-axis wind turbines operating under a wide range of conditions in Europe. The subject turbines covered a broad spectrum of rotor diameters, materials, and operating environments. The final loading sequences were developed as a joint effort of thirteen different European organizations. The goal was to develop a meaningful loading standard for horizontal-axis wind turbine blades that represents common interaction effects seen in service. In 1990, NREL made extensive load measurements on two adjacent Micon 65/13 wind turbines in simultaneous operation in the very turbulent environment of a large wind park. Further, before and during the collection of the loads data, comprehensive measurements of the statistics of the turbulent environment were obtained at both the turbines under test and at two other locations within the park. The trend to larger but lighter wind turbine structures has made an understanding of the expected lifetime loading history of paramount importance. Experience in the US has shown that the turbulence-induced loads associated with multi-row wind parks in general are much more severe than for turbines operating individually or within widely spaced environments. Multi-row wind parks are much more common in the US than in Europe. In this paper we report on our results in applying the methodology utilized to develop the WISPER and WISPERX standardized loading sequences using the available data from the Micon turbines. While the intended purpose of the WISPER sequences were not to represent a specific operating environment, we believe the exercise is useful, especially when a turbine design is likely to be installed in a multi-row wind park.

Kelley, N.D.

1995-01-01T23:59:59.000Z

167

Comparison of Building Energy Modeling Programs: Building Loads  

NLE Websites -- All DOE Office Websites (Extended Search)

Comparison of Building Energy Modeling Programs: Building Loads Title Comparison of Building Energy Modeling Programs: Building Loads Publication Type Report LBNL Report Number...

168

The Effect of Daylighting Strategies on Building Cooling Loads...  

NLE Websites -- All DOE Office Websites (Extended Search)

The Effect of Daylighting Strategies on Building Cooling Loads and Overall Energy Performance Title The Effect of Daylighting Strategies on Building Cooling Loads and Overall...

169

Repository Reference Disposal Concepts and Thermal Load Management...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Repository Reference Disposal Concepts and Thermal Load Management Analysis Repository Reference Disposal Concepts and Thermal Load Management Analysis A disposal concept consists...

170

Definition: Dispersed Load By Substations | Open Energy Information  

Open Energy Info (EERE)

By Substations Jump to: navigation, search Dictionary.png Dispersed Load By Substations Substation load information configured to represent a system for power flow or system...

171

Methods and apparatus for reduction of asymmetric rotor loads in ...  

A method for reducing load and providing yaw alignment in a wind turbine includes measuring displacements or moments resulting from asymmetric loads on the wind turbine.

172

Building Energy Software Tools Directory: Prophet Load Profiler  

NLE Websites -- All DOE Office Websites (Extended Search)

Shots Keywords energy analysis, load profiling, cost comparison, energy budgeting, rate analysis, data collection, real-time monitoring, load shedding ValidationTesting NA...

173

Energetical factors in power systems with nonlinear loads  

Science Conference Proceedings (OSTI)

Based on the volt-ampere charac- teristic of the nonlinear load, an equivalent circuit, containing linear elements, can be determined. In this way, load-flow and.

174

Used Nuclear Fuel Loading and Structural Performance Under Normal...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Used Nuclear Fuel Loading and Structural Performance Under Normal Conditions of Transport - Modeling, Simulation and Experimental Integration RD&D Plan Used Nuclear Fuel Loading...

175

Definition: Direct Control Load Management | Open Energy Information  

Open Energy Info (EERE)

Control Load Management Jump to: navigation, search Dictionary.png Direct Control Load Management Demand-Side Management that is under the direct control of the system operator....

176

Definition: Circuit Peak Load Management | Open Energy Information  

Open Energy Info (EERE)

Circuit Peak Load Management Jump to: navigation, search Dictionary.png Circuit Peak Load Management An application utilizing sensors, information processors, communications, and...

177

Definition: Real-Time Load Transfer | Open Energy Information  

Open Energy Info (EERE)

Real-time load transfer is achieved through real-time feeder reconfiguration and optimization to relieve load on equipment, improve asset utilization, improve distribution...

178

Load Control for System Reliability and Measurement-Based Stability...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Load Control for System Reliability and Measurement-Based Stability Assessment Load Control for System Reliability and Measurement-Based Stability Assessment Research and develop...

179

Load attenuating passively adaptive wind turbine blade  

DOE Patents (OSTI)

A method and apparatus for improving wind turbine performance by alleviating loads and controlling the rotor. The invention employs the use of a passively adaptive blade that senses the wind velocity or rotational speed, and accordingly modifies its aerodynamic configuration. The invention exploits the load mitigation prospects of a blade that twists toward feather as it bends. The invention includes passively adaptive wind turbine rotors or blades with currently preferred power control features. The apparatus is a composite fiber horizontal axis wind-turbine blade, in which a substantial majority of fibers in the blade skin are inclined at angles of between 15 and 30 degrees to the axis of the blade, to produces passive adaptive aeroelastic tailoring (bend-twist coupling) to alleviate loading without unduly jeopardizing performance.

Veers, Paul S. (Albuquerque, NM); Lobitz, Donald W. (Albuquerque, NM)

2003-01-01T23:59:59.000Z

180

On loading rate effects in toughening processes  

SciTech Connect

Environmental crack tip reactions are a known source of premature fracture in oxides. These rate-dependent phenomena commonly are studied in strength tests where loading rate serves as the major experimental variable. A material susceptible to environmentally-assisted crack growth is stronger at fast testing rates. A topic which has received far less attention is the influence of stressing rate or loading rate on the shielding processes which occur at some distance from the crack tip, although the inverse has been studied by Deuerler et al. The authors present here the first known documentation of a loading rate effect on shielding phenomena in ceramic materials. For these experiments Coors AD 94 alumina was chosen for study.

Tandon, S.; Faber, K.T. [Northwestern Univ., Evanston, IL (United States)

1996-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "loading front loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Estimating Demand Response Load Impacts: Evaluation of Baseline Load Models for Non-Residential Buildings in California  

E-Print Network (OSTI)

This  baseline  load  profile  (BLP)  is  key  to to  as  the  baseline  load  profile  or  BLP  and  is  key actual  and  estimated  load  profiles  look,  Figure  1 

Coughlin, Katie; Piette, Mary Ann; Goldman, Charles; Kiliccote, Sila

2008-01-01T23:59:59.000Z

182

SYSPLAN. Load Leveling Battery System Costs  

SciTech Connect

SYSPLAN evaluates capital investment in customer side of the meter load leveling battery systems. Such systems reduce the customer`s monthly electrical demand charge by reducing the maximum power load supplied by the utility during the customer`s peak demand. System equipment consists of a large array of batteries, a current converter, and balance of plant equipment and facilities required to support the battery and converter system. The system is installed on the customer`s side of the meter and controlled and operated by the customer. Its economic feasibility depends largely on the customer`s load profile. Load shape requirements, utility rate structures, and battery equipment cost and performance data serve as bases for determining whether a load leveling battery system is economically feasible for a particular installation. Life-cycle costs for system hardware include all costs associated with the purchase, installation, and operation of battery, converter, and balance of plant facilities and equipment. The SYSPLAN spreadsheet software is specifically designed to evaluate these costs and the reduced demand charge benefits; it completes a 20 year period life cycle cost analysis based on the battery system description and cost data. A built-in sensitivity analysis routine is also included for key battery cost parameters. The life cycle cost analysis spreadsheet is augmented by a system sizing routine to help users identify load leveling system size requirements for their facilities. The optional XSIZE system sizing spreadsheet which is included can be used to identify a range of battery system sizes that might be economically attractive. XSIZE output consisting of system operating requirements can then be passed by the temporary file SIZE to the main SYSPLAN spreadsheet.

Hostick, C.J. [Pacific Northwest Lab., Richland, WA (United States)

1988-03-22T23:59:59.000Z

183

Matching equipment size to the cooling load  

SciTech Connect

This article presents a heat extraction rate analysis method, using ASHRAE algorithms that enables HVAC system designers to optimally size cooling equipment. The final stage of the cooling load calculation process determines the heat extraction rate required to achieve design conditions. Put another way, this stage determines the equipment capacity required to match the cooling load profile, and it does so in a manner that predicts the resulting space temperature profile, and it does so in a manner that predicts the resulting space temperature profile. It is a stage in the design process that, in practice, may not be given the attention it deserves.

Bloom, B. (Harvey Toub Engineering, Atlanta, GA (United States))

1993-10-01T23:59:59.000Z

184

Demand-Side Response from Industrial Loads  

Science Conference Proceedings (OSTI)

Through a research study funded by the Department of Energy, Smart Grid solutions company ENBALA Power Networks along with the Oak Ridge National Laboratory (ORNL) have geospatially quantified the potential flexibility within industrial loads to leverage their inherent process storage to help support the management of the electricity grid. The study found that there is an excess of 12 GW of demand-side load flexibility available in a select list of top industrial facilities in the United States. Future studies will expand on this quantity of flexibility as more in-depth analysis of different industries is conducted and demonstrations are completed.

Starke, Michael R [ORNL; Alkadi, Nasr E [ORNL; Letto, Daryl [Enbala Power Networks; Johnson, Brandon [University of Tennessee, Knoxville (UTK); Dowling, Kevin [University of Tennessee, Knoxville (UTK); George, Raoule [Enbala Power Networks; Khan, Saqib [University of Texas, Austin

2013-01-01T23:59:59.000Z

185

New method developed for LPG offshore loading  

SciTech Connect

An innovative concept for refrigerated LPG offshore loading has been developed by TOTAL and Enterprise D'Equipments Mecaniques at Hydrauliques. Known as CHAGAL, the system integrates with the catenary anchor leg mooring offshore loading system commonly used for crude oil. CHAGAL provides a suitable answer to short-term development schemes of LPG trade. It can be adapted for possible extrapolation to cryogenic temperatures of LNG and it opens a new way to the development of offshore liquefaction projects for which the offloading of production is still an unsolved key problem.

1985-10-01T23:59:59.000Z

186

LOADED WAVE GUIDES FOR LINEAR ACCELERATORS  

DOE Patents (OSTI)

A periodically loaded waveguide having substantially coaxially arranged elements which provide an axial field for the acceleration of electrons is described. Radiofrequency energy will flow in the space between the inner wall of an outer guide and the peripheries of equally spaced irises or washes arranged coaxially with each other and with the outer guide, where the loading due to the geometry of the irises is such as to reduce the phase velocity of the r-f energy flowing in the guide from a value greater than that of light to the velocity of light or less.

Walkinshaw, W.; Mullett, L.B.

1959-12-01T23:59:59.000Z

187

Load relaxation studies of a metallic glass  

SciTech Connect

Experimental results of load relaxation studies of a commercial metallic glass as a function of temperature are reported. The data suggest that metallic glasses exhibit deformation behavior with flow laws similar to those governing plastic deformation in crystalline solids. The lack of appreciable work hardening in annealed material and the identification of an anelastic component are also indicated by the experimental observations. (GHT)

Hadnagy, T.D.; Krenisky, D.J.; Ast, D.G.; Li, C.Y.

1977-01-01T23:59:59.000Z

188

Flexible loads in future energy networks  

Science Conference Proceedings (OSTI)

We develop a vignette of an information-rich energy network with flexible and responsive electrical loads in the form of a domestic refrigerator augmented with a thermal storage system and a supply-following controller that responds to the availability ... Keywords: renewable, supply-following

Jay Taneja, Ken Lutz, David Culler

2013-01-01T23:59:59.000Z

189

Exercising flexible load contracts: Two simple strategies  

Science Conference Proceedings (OSTI)

A flexible load contract is a type of swing option where the holder has the right to receive a given quantity of electricity within a specified period, at a fixed maximum effect (delivery rate). The contract is flexible, in the sense that delivery (the ... Keywords: energy, exercise strategy, flexibility, swing option, uncertainty

Petter Bjerksund; Bjarte Myksvoll; Gunnar Stensland

2008-03-01T23:59:59.000Z

190

Demand or Request: Will Load Behave?  

Science Conference Proceedings (OSTI)

Power planning engineers are trained to design an electric system that satisfies predicted electrical demand under stringent conditions of availability and power quality. Like responsible custodians, we plan for the provision of electrical sustenance and shelter to those in whose care regulators have given us the responsibility to serve. Though most customers accept this nurturing gladly, a growing number are concerned with the economic costs and environmental impacts of service at a time when technology (particularly distributed generation, storage, automation, and information networks) offers alternatives for localized control and competitive service. As customers’ and their systems mature, a new relationship with the electricity provider is emerging. Demand response is perhaps the first unsteady step where the customer participates as a partner in system operations. This paper explores issues system planners need to consider as demand response matures to significant levels beyond direct load control and toward a situation where service is requested and bargains are reached with the electricity provider based on desired load behavior. On one hand, predicting load growth and behavior appears more daunting than ever. On the other, for the first time load becomes a new resource whose behavior can be influenced during system operations to balance system conditions.

Widergren, Steven E.

2009-07-30T23:59:59.000Z

191

Incentivizing Advanced Load Scheduling in Smart Homes  

Science Conference Proceedings (OSTI)

In recent years, researchers have proposed numerous advanced load scheduling algorithms for smart homes with the goal of reducing the grid's peak power usage. In parallel, utilities have introduced variable rate pricing plans to incentivize residential ... Keywords: Battery, Electricity, Energy, Grid

Ye Xu, David Irwin, Prashant Shenoy

2013-11-01T23:59:59.000Z

192

Appliance Commitment for Household Load Scheduling  

Science Conference Proceedings (OSTI)

This paper presents a novel appliance commitment algorithm that schedules thermostatically-controlled household loads based on price and consumption forecasts considering users comfort settings to meet an optimization objective such as minimum payment or maximum comfort. The formulation of an appliance commitment problem was described in the paper using an electrical water heater load as an example. The thermal dynamics of heating and coasting of the water heater load was modeled by physical models; random hot water consumption was modeled with statistical methods. The models were used to predict the appliance operation over the scheduling time horizon. User comfort was transformed to a set of linear constraints. Then, a novel linear, sequential, optimization process was used to solve the appliance commitment problem. The simulation results demonstrate that the algorithm is fast, robust, and flexible. The algorithm can be used in home/building energy-management systems to help household owners or building managers to automatically create optimal load operation schedules based on different cost and comfort settings and compare cost/benefits among schedules.

Du, Pengwei; Lu, Ning

2011-06-30T23:59:59.000Z

193

Valve for fuel pin loading system  

DOE Patents (OSTI)

A cyclone valve surrounds a wall opening through which cladding is projected. An axial valve inlet surrounds the cladding. Air is drawn through the inlet by a cyclone stream within the valve. An inflatable seal is included to physically engage a fuel pin subassembly during loading of fuel pellets.

Christiansen, D.W.

1984-01-01T23:59:59.000Z

194

Lifeline-based global load balancing  

Science Conference Proceedings (OSTI)

On shared-memory systems, Cilk-style work-stealing has been used to effectively parallelize irregular task-graph based applications such as Unbalanced Tree Search (UTS). There are two main difficulties in extending this approach to distributed memory. ... Keywords: distributed work-stealing, global load balancing, uts, x10

Vijay A. Saraswat; Prabhanjan Kambadur; Sreedhar Kodali; David Grove; Sriram Krishnamoorthy

2011-02-01T23:59:59.000Z

195

Propagation in LHM slab loaded rectangular waveguide  

Science Conference Proceedings (OSTI)

The strange properties of Left - Handed Materials (LHM), whose permittivity and permeability are both negative, is briefly introduced. The electric- and magnetic-field components are given in rectangular waveguide loaded with LHM by use of field component ... Keywords: cutoff wavelength, dispersion equation, group velocity, left-handed materials, rectangular waveguide

Rui-Lian Li

2011-09-01T23:59:59.000Z

196

Economic load dispatch using improved harmony search  

Science Conference Proceedings (OSTI)

This paper presents the use of the improved harmony search method for solving economic load dispatch problems. The harmony search method mimics a jazz improvisation process by musicians in order to seek a fantastic state of harmony. To assess the searching ... Keywords: adaptive tabu search, economic dispatch, evolutionary programming, genetic algorithms, particle swarm optimization

T. Ratniyomchai; A. Oonsivilai; P. Pao-La-Or; T. Kulworawanichpong

2010-04-01T23:59:59.000Z

197

Load forecast and treatment of conservation  

E-Print Network (OSTI)

Load forecast and treatment of conservation July 28th 2010 Resource Adequacy Technical Committee conservation is implicitly incorporated in the short-term demand forecast? #12;3 Incorporating conservation in the short-term model Our short-term model is an econometric model which can not explicitly forecast

198

1995 Pacific Northwest Loads and Resources Study.  

Science Conference Proceedings (OSTI)

The study establishes the planning basis for supplying electricity to customers. The study presents projections of regional and Federal system load and resource capabilities, and serves as a benchmark for annual BPA determinations made pursuant to the 1981 regional power sales contracts.

United States. Bonneville Power Administration.

1995-12-01T23:59:59.000Z

199

Valve for fuel pin loading system  

DOE Patents (OSTI)

A cyclone valve surrounds a wall opening through which cladding is projected. An axial valve inlet surrounds the cladding. Air is drawn through the inlet by a cyclone stream within the valve. An inflatable seal is included to physically engage a fuel pin subassembly during loading of fuel pellets.

Christiansen, David W. (Kennewick, WA)

1985-01-01T23:59:59.000Z

200

Independent review of estimated load reductions for PJM's small customer load response pilot project  

SciTech Connect

This study describes the results of a low-cost approach used to measure reported load reductions from a residential electric water heater (EWH) load control program operated as part of PJM Interconnection's Demand Response small customer pilot program. Lawrence Berkeley National Laboratory (LBNL) conducted this independent review of the engineering estimates for EWH load control reported by a Curtailment Service Provider (CSP) at PJM's request. LBNL employed low-cost measurement and verification (M&V) approaches that utilized existing interval metering equipment to monitor results for a series of load control tests. The CSP collected hourly load data for two substations and several hundred households over a six-week period in October and November 2003. During this time period, the CSP operated its electric water heater load control program during pre-specified test periods in the morning, afternoon and early evening. LBNL then analyzed substation and premise-level data from these tests in order to verify the diversified demand reductions claimed by the CSP for customers participating in the EWH load control program. We found that the observed load reductions for the premise-level data aggregated over all households in the two participating electric cooperatives were, respectively, 40 percent-60 percent less and 3 percent less-10 percent higher than the estimated diversified demand reduction values assumed by the CSP, depending on whether observed or normalized results are considered. We also analyzed sub-station level data and found that the observed load reductions during the test periods were significantly lower than expected, although confounding influences and operational problems signifiogram during pre-specified test periods in the morning, afternoon and early evening. LBNL then analyzed substation and premise-level data from these tests in order to verify the diversified demand reductions claimed by the CSP for customers participating in the EWH load control program. We found that the observed load reductions for the premise-level data aggregated over all households in the two participating electric cooperatives were, respectively, 40 percent-60 percent less and 3 percent less-10 percent higher than the estimated diversified demand reduction values assumed by the CSP, depending on whether observed or normalized results are considered. We also analyzed sub-station level data and found that the observed load reductions during the test periods were significantly lower than expected, although confounding influences and operational problems significantly limit our ability to differentiate between control-related and non-control related differences in substation-level load shape data. The usefulness and accuracy of the results were hampered by operational problems encountered during the measurement period as well as in sufficient number of load research grade interval meters at one cooperative. Given the larger sample size at one electric cooperative and more statistically-robust results, there is some basis to suggest that the Adjusted Diversified Demand Factor (ADDF) values used by the CSP somewhat over-state the actual load reductions. Given the results and limitations of the M&V approach as implemented, we suggest several options for PJM to consider: (1) require load aggregators participating in ISODR programs to utilize formal PURPA-compliant load research samples in their M&V plans, and (2) continue developing lower cost M&V approaches for mass market load control programs that incorporate suggested improvements described in this study.

Heffner, G.; Moezzi, M.; Goldman, C.

2004-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "loading front loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Microarchitecture support for improving the performance of load target prediction  

Science Conference Proceedings (OSTI)

Presents a load target prediction scheme that mitigates the impact of load latency for modern microprocessors. The scheme uses a cache-like buffer to provide the base address, offset and operand size at the instruction fetching stage of a pipeline so ... Keywords: load target prediction, load-use stall, pipeline, speculative data access, superscalar procesor

Chung-Ho Chen; Akida Wu

1997-12-01T23:59:59.000Z

202

Load Balancing Content-Based Publish/Subscribe Systems  

Science Conference Proceedings (OSTI)

Distributed content-based publish/subscribe systems suffer from performance degradation and poor scalability caused by uneven load distributions typical in real-world applications. The reason for this shortcoming is the lack of a load balancing scheme. ... Keywords: PADRES, Publish/subscribe, ToPSS, content-based routing, load balancing, load estimation, offload algorithms, subscriber migration

Alex King Yeung Cheung; Hans-Arno Jacobsen

2010-12-01T23:59:59.000Z

203

Vehicle Tank & Loading Rack Meters - 2013-04-22  

Science Conference Proceedings (OSTI)

Vehicle Tank & Loading Rack Meters. Purpose: ... Participants should bring a calculator to the training. Materials & Supplies: ...

2013-06-03T23:59:59.000Z

204

Classification and forecasting of load curves Nolwen Huet  

E-Print Network (OSTI)

on up to stabilisation of the clusters. Finally, the load profiles are predicted by covariance analysis of electricity customer uses. This load curve is only available for customers with automated meter readingClassification and forecasting of load curves Nolwen Huet Abstract The load curve, which gives

Cuesta, Juan Antonio

205

Reliability analysis of RC containment structures under combined loads  

SciTech Connect

This paper discusses a reliability analysis method and load combination design criteria for reinforced concrete containment structures under combined loads. The probability based reliability analysis method is briefly described. For load combination design criteria, derivations of the load factors for accidental pressure due to a design basis accident and safe shutdown earthquake (SSE) for three target limit state probabilities are presented.

Hwang, H.; Reich, M.; Kagami, S.

1984-01-01T23:59:59.000Z

206

The Temperature Sensitivity of the Residential Load and Commercial Building Load  

SciTech Connect

This paper presents a building modeling approach to quickly quantify climate change impacts on energy consumption, peak load, and load composition of residential and commercial buildings. This research focuses on addressing the impact of temperature changes on the building heating and cooling load in 10 major cities across the Western United States and Canada. A building simulation software are first used to quantify the hourly energy consumption of different building types by end-use and by vintage. Then, the temperature sensitivities are derived based on the climate data inputs.

Lu, Ning; Taylor, Zachary T.; Jiang, Wei; Correia, James; Leung, Lai R.; Wong, Pak C.

2009-07-26T23:59:59.000Z

207

Comparison of Zone Cooling Load for Radiant and All-Air Conditioning Systems  

E-Print Network (OSTI)

change the cooling load profile for the mechanical systems.and the resulting cooling load profile has been reported inimplications for cooling load profile and peak cooling load

Feng, Jingjuan; Schiavon, Stefano; Bauman, Fred

2012-01-01T23:59:59.000Z

208

Technical Update: Load Modeling in Power System Studies  

Science Conference Proceedings (OSTI)

EPRI has been engaged in load modeling research since the 1980’s. In the past, EPRI conducted significant research in the area of load modeling and worked together with the Western Electricity Coordinating Council (WECC) Load Modeling Task Force in the development of the new composite load model developed and currently to be deployed in WECC. This work included extensive testing of various load components, such as residential air-conditioners, in the EPRI laboratories in Knoxville, TN. In ...

2013-12-10T23:59:59.000Z

209

Conductor Wind Loading--Results of EPRI Field Validation Studies  

Science Conference Proceedings (OSTI)

A comprehensive evaluation of current wind load methods indicates that several factors can adversely affect the performance of wind load models. There are wide variations and biased values associated with some of the wind parameters, and inaccurate drag coefficient and air density values can influence the wind load models. Several modified approaches were tested to properly incorporate wind gusts and spatial effects in wind load calculations. The improvement in the wind load predictions made by some of t...

1995-05-12T23:59:59.000Z

210

Estimating Demand Response Load Impacts: Evaluation of Baseline Load Models for Non-Residential Buildings in California  

E-Print Network (OSTI)

energy  use  for  space  conditioning,  non? weather Physically,  space?conditioning  loads  are  affected  by 

Coughlin, Katie; Piette, Mary Ann; Goldman, Charles; Kiliccote, Sila

2008-01-01T23:59:59.000Z

211

Load-shape modeling in southeastern utility systems  

SciTech Connect

Load models are tools which have a wide range of application in the electric-utility industry. Some uses include monitoring load-management policies and helping with on-line commitment problems. The output from a load model can be placed in a suitable software environment where daily load curves are computed and displayed. Also, load models can be extended to perform forecasting functions. A weather sensitive load model that takes into account both weekdays and weekends on an hourly basis has been developed and applied to load shape modeling and short term forecasting on three southeastern electric utilities. A software package associated with the load modeling theory was developed and tested. This load-modeling program computes the daily load curve in terms of identifiable components. The program uses historical hourly load data to compute coefficients related to load components including base, growth, seasonal and weather. These coefficients can be used in a mathematical model to compute an estimate of the daily load curve with load values for each hour of the day. The load-modeling procedure described employs a linear least squares method for computing coefficients in the mathematical model.

Lebby, G.L.

1985-01-01T23:59:59.000Z

212

2012 CERTS LAAR Program Peer Review - Integration and Extension of Direct Load Management of Smart Loads - Anna Scaglioni, UC Davis  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Integration and Extension of Direct Integration and Extension of Direct Load Management of Smart Loads Anna Scaglione, UC Davis GRA: Mahnoosh Alizadeh Project objective  Invent methods to "store" load demand for * Real-time "generation following" * Integration of load reserves as dispatchable assets in the Energy Market  Architecture for virtual "reserves" (queues) of electrical load demand * Watts to Job mapping (analysis)  Captures digitally the service requirements - Equal service type = Equal queue * Job to Watts mapping (synthesis)  Allows to optimally schedule the load profile Major technical accomplishments  Centralized model: Digital Direct Load Scheduling (DDLS) - Year 1-Year 2

213

A new generation of load sharing algorithms: the semi-adaptive load sharing algorithm  

E-Print Network (OSTI)

Distributed systems have become a popular computing environment. Due to their high potentials in improving performance and resource sharing, the evolution and maturing of technologies such as networks and computer hardware, have led to more realizations of distributed computing capabilities. One of the key factors that impacts the system's performance is how load sharing is handled. Most of the work done in load sharing algorithms focused on either one of two approaches: the static approach, or the dynamic approach. Static load sharing is characterized with its simplicity and minimal overhead induced on the system when performing load distribution. This is attributed to the fact that their load sharing decisions do not require any information exchange between nodes. However, static algorithms are not capable of adapting to traffic changes. Hence, this will affect the distributed system adaptability and stability features against load alteration. The second approach in load sharing algorithums is the dynamic approach. In this approach, nodes base their sharing decisions on the knowledge of the status on other nodes. This knowledge enables nodes to make improved decisions when selecting a remote execution site. Therefore, these algorithms provide the distributed system with adaptability and stability. Nevertheless, information exchange between nodes has proven to be expensive. The problem lies in the communication and processing overheads which these algorithms impose on the system. This research work presents a Semi-Adaptive load sharing approach that attempts to lay a common ground between the dynamic and the static approaches. This approach provides the system with adaptability features at are supplied with tools to control the level of adaptability and information exchange in the system. It is argued that this approach is adaptable, scalable, stable, fault tolerant, and will generate low and controlled system overheads. Two implementations of the Semi-Adaptive approach are presented: The Controller Load Sharing Protocol (CLSP) and The Pool Load Sharing Protocol (PLSP). The study of CLSP and PLSP include simulating their performance under various conditions. The simulation include comparing the performance of these two protocols against two load sharing algorithms representing the static and dynamic families. Furthermore, the properties of CLSP and PLSP are investigated. Finally, based on the study and analysis of both protocols, the research work proposes possible areas of improvement in the final conclusion.

Morsy, Hazem Kamal

1997-01-01T23:59:59.000Z

214

Calculations of slurry pump jet impingement loads  

SciTech Connect

This paper presents a methodology to calculate the impingement load in the region of a submerged turbulent jet where a potential core exits and the jet is not fully developed. The profile of the jet flow velocities is represented by a piece-wise linear function which satisfies the conservation of momentum flux of the jet flow. The adequacy of the of the predicted jet expansion is further verified by considering the continuity of the jet flow from the region of potential core to the fully developed region. The jet impingement load can be calculated either as a direct impingement force or a drag force using the jet velocity field determined by the methodology presented.

Wu, T.T.

1996-03-04T23:59:59.000Z

215

Two-phase jet loads. [PWR  

Science Conference Proceedings (OSTI)

Two-phase jets are currently being studied to improve engineering models for the prediction of loads on pipes and structures during LOCAs. Multi-dimensional computer codes such as BEACON/MOD2, CSQ, and TRAC-P1A are being employed to predict flow characteristics and flow-structure loading. Our ultimate goal is to develop a new approximate engineering model which is superior to the F.J. Moody design model. Computer results are compared with data obtained from foreign sources, and a technique for using the TRAC-P1A vessel component as a containment model is presented. In general, good agreement with the data is obtained for saturated stagnation conditions; however, difficulties are encountered for subcooled stagnation conditions, possibly due to nucleation delay and non-equilibrium effects.

Tomasko, D.

1980-01-01T23:59:59.000Z

216

NREL: Vehicle Ancillary Loads Reduction - Integrated Modeling  

NLE Websites -- All DOE Office Websites (Extended Search)

Integrated Modeling Integrated Modeling NREL's Vehicle Ancillary Loads Reduction (VALR) team predicts the impact of advanced vehicle cooling technologies before testing by using an integrated modeling process. Evaluating the heat load on a vehicle under real world conditions is a difficult task. An accepted method to evaluate passenger compartment airflow and heat transfer is computational fluid dynamics. (CFD). Combining analytical models with CFD provides a powerful tool to assist industry both on current vehicles and on future design studies. Flow chart showing the vehicle integrated modeling process which considers solar radiation, air conditioning, and vehicles with CAD, glazing, cabin thermal/fluid, and thermal comfort modeling tools. Results are provided for fuel economy, tailpipe emissions and occupant thermal comfort.

217

EPRI/GRI Load Shape Workshop: Load Data Analysis for Gas and Electric Markets  

Science Conference Proceedings (OSTI)

Load shapes, representing usage patterns in the electric and gas industry, are a key factor in energy company operations and management. In the emerging restructured energy market, retail energy suppliers market energy to final customers and must arrange for electricity generation or gas delivery to meet their customers' needs. EPRI and GRI sponsored a two-day workshop in June, 1999 that addressed a range of issues associated with load shapes, including modeling, profiling for retail market settlement, r...

1999-11-10T23:59:59.000Z

218

Load diagram for a perforated plate tray  

E-Print Network (OSTI)

1 decimals noggrannhet c. Upprita i x,y-diagrammet q-linjen och bestäm (grafiskt, eller med must be produced. The feed stream F is a saturated liquid, i.e. q = 1, while the reflux ratio R = 1Load diagram for a perforated plate tray vG, vL: velocities G, L: densities QL, QG: volume flows H

Zevenhoven, Ron

219

Composition containing aerogel substrate loaded with tritium  

DOE Patents (OSTI)

The invention provides a process for loading an aerogel substrate with tritium and the resultant compositions. According to the process, an aerogel substrate is hydrolyzed so that surface OH groups are formed. The hydrolyzed aerogel is then subjected to tritium exchange employing, for example, a tritium-containing gas, whereby tritium atoms replace H atoms of surface OH groups. OH and/or CH groups of residual alcohol present in the aerogel may also undergo tritium exchange.

Ashley, Carol S. (Albuquerque, NM); Brinker, C. Jeffrey (Albuquerque, NM); Ellefson, Robert E. (Centerville, OH); Gill, John T. (Miamisburg, OH); Reed, Scott (Albuquerque, NM); Walko, Robert J. (Albuquerque, NM)

1992-01-01T23:59:59.000Z

220

Electricity pricing for conservation and load shifting  

Science Conference Proceedings (OSTI)

The electricity industry is facing the challenge of increasing costs of reliably meeting demand growth and fully complying with legislative renewable portfolio standards and greenhouse gas reduction targets. However, an electric utility's existing tariffs often don't have rates that increase with consumption volume or vary by time of use, thus not fully exploiting the potential benefits from customer conservation and load shifting. (author)

Orans, Ren; Woo, C.K.; Horii, Brian; Chait, Michele; DeBenedictis, Andrew

2010-04-15T23:59:59.000Z

Note: This page contains sample records for the topic "loading front loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Combined transmission distribution load flow model employing system reduction and voltage variable load representation  

SciTech Connect

In the few decades since its introduction the digital computer has found widespread application within the electric power industry. One of the more fruitful areas for its utilization has been in the determination of the steady-state voltage conditions throughout the system. A power system naturally breaks down into two very distinct parts: transmission and distribution, and traditionally, the voltage problem has been separated the same way. In the transmission system it is referred to as a load flow problem, and in the distribution part it is called a voltage profile. In addition, the loads are often treated differently. Transmission loads are usually considered to be constant power, and the equations that result are therefore nonlinear. In the distribution portion the loads, though specified in terms of power, are sometimes handled as constant impedances, with linear equations. This work produced a new model wherein a mesh transmission system is combined with a radial distribution system and they are solved simultaneously. A system reduction technique is used to eliminate part of the transmission system from consideration, and thereby keep the problem at a manageable size. The solution algorithm incorporates a voltage variable load model which approximates the behavior of real loads more nearly than the common representations.

Enouen, P.W.

1985-01-01T23:59:59.000Z

222

ALPHA ATTENUATION DUE TO DUST LOADING  

SciTech Connect

Previous studies had been done in order to show the attenuation of alpha particles in filter media. These studies provided an accurate correction for this attenuation, but there had not yet been a study with sufficient results to properly correct for attenuation due to dust loading on the filters. At the Savannah River Site, filter samples are corrected for attenuation due to dust loading at 20%. Depending on the facility the filter comes from and the duration of the sampling period, the proper correction factor may vary. The objective of this study was to determine self-absorption curves for each of three counting instruments. Prior work indicated significant decreases in alpha count rate (as much as 38%) due to dust loading, especially on filters from facilities where sampling takes place over long intervals. The alpha count rate decreased because of a decrease in the energy of the alpha. The study performed resulted in a set of alpha absorption curves for each of three detectors. This study also took into account the affects of the geometry differences in the different counting equipment used.

Dailey, A; Dennis Hadlock, D

2007-08-09T23:59:59.000Z

223

Load controller and method to enhance effective capacity of a photovotaic power supply using a dynamically determined expected peak loading  

DOE Patents (OSTI)

A load controller and method are provided for maximizing effective capacity of a non-controllable, renewable power supply coupled to a variable electrical load also coupled to a conventional power grid. Effective capacity is enhanced by monitoring power output of the renewable supply and loading, and comparing the loading against the power output and a load adjustment threshold determined from an expected peak loading. A value for a load adjustment parameter is calculated by subtracting the renewable supply output and the load adjustment parameter from the current load. This value is then employed to control the variable load in an amount proportional to the value of the load control parameter when the parameter is within a predefined range. By so controlling the load, the effective capacity of the non-controllable, renewable power supply is increased without any attempt at operational feedback control of the renewable supply. The expected peak loading of the variable load can be dynamically determined within a defined time interval with reference to variations in the variable load.

Perez, Richard (Delmar, NY)

2003-04-01T23:59:59.000Z

224

Definition: Direct Load Control Device | Open Energy Information  

Open Energy Info (EERE)

Load Control Device Load Control Device Jump to: navigation, search Dictionary.png Direct Load Control Device A remotely controllable switch that can turn power to a load or appliance on or off. Such a device could also be used to regulate the amount of power that a load can consume. Direct load control devices can be operated by a utility or third party energy provider to reduce a customer's energy demand at certain times.[1] Related Terms power, load References ↑ https://www.smartgrid.gov/category/technology/direct_load_control_device [[Ca LikeLike UnlikeLike You like this.Sign Up to see what your friends like. tegory: Smart Grid Definitionssmart grid,smart grid, |Template:BASEPAGENAME]]smart grid,smart grid, Retrieved from "http://en.openei.org/w/index.php?title=Definition:Direct_Load_Control_Device&oldid=502631

225

G&T adds versatile load management system  

SciTech Connect

Wolverine`s load management system was designed in response to the need to reduce peak demand. The Energy Management System (EMS) prepares short term (seven day) load forecasts, based on a daily peak demand forecst, augmented by a similar day profile based on weather conditions. The software combines the similar day profile with the daily peak demand forecast to yield an hourly load forecast for an entire week. The software uses the accepted load forecast case in many application functions, including interchange scheduling, unit commitment, and transaction evaluation. In real time, the computer updates the accepted forecast hourly, based in actual changes in the weather and load. The load management program executes hourly. The program uses impact curves to calculate a load management strategy that reduces the load forecast below a desired load threshold.

Nickel, J.R.; Baker, E.D.; Holt, J.W.; Chan, M.L.

1995-04-01T23:59:59.000Z

226

Residential equipment part load curves for use in DOE-2  

SciTech Connect

DOE-2 (DOE2 90) includes several correlation curves that predict the energy use of systems underpart load conditions. DOE-2 simulates systems on an hour-by-hour basis, so the correlations are intended to predict part load energy use (and efficiency) as a function of the part load ratio (PLR) for each hour, where PLR = Hourly Load/Available Capacity. Generally residential and small commercial HVAC equipment meets the load at off-design conditions by cycling on and off. Therefore, the part load correlations must predict the degradation due to this on and off operation over an hourly interval.

Henderson, Hugh; Huang, Y.J.; Parker, D.

1999-02-01T23:59:59.000Z

227

The effect of load parameters on system thermal performance  

SciTech Connect

The effects of load size, load profile and hot water set temperature on system thermal performance are investigated in order to determine the relative importance of these design parameters in sizing a solar water heating system. The WATSUN IV computer program was used to introduce various load sizes, load profiles and set temperatures to a base model. The results indicate that variations in load size have a significant effect on the thermal performance of the system. However, variations in load profile and hot water set temperature seem to have no significant effect on system performance.

Vakili, M.

1984-02-01T23:59:59.000Z

228

Methods for Analyzing Electric Load Shape and its Variability  

Science Conference Proceedings (OSTI)

Current methods of summarizing and analyzing electric load shape are discussed briefly and compared. Simple rules of thumb for graphical display of load shapes are suggested. We propose a set of parameters that quantitatively describe the load shape in many buildings. Using the example of a linear regression model to predict load shape from time and temperature, we show how quantities such as the load?s sensitivity to outdoor temperature, and the effectiveness of demand response (DR), can be quantified. Examples are presented using real building data.

Price, Philip

2010-05-12T23:59:59.000Z

229

SLUDGE TREATMENT PROJECT COST COMPARISON BETWEEN HYDRAULIC LOADING AND SMALL CANISTER LOADING CONCEPTS  

SciTech Connect

The Sludge Treatment Project (STP) is considering two different concepts for the retrieval, loading, transport and interim storage of the K Basin sludge. The two design concepts under consideration are: (1) Hydraulic Loading Concept - In the hydraulic loading concept, the sludge is retrieved from the Engineered Containers directly into the Sludge Transport and Storage Container (STSC) while located in the STS cask in the modified KW Basin Annex. The sludge is loaded via a series of transfer, settle, decant, and filtration return steps until the STSC sludge transportation limits are met. The STSC is then transported to T Plant and placed in storage arrays in the T Plant canyon cells for interim storage. (2) Small Canister Concept - In the small canister concept, the sludge is transferred from the Engineered Containers (ECs) into a settling vessel. After settling and decanting, the sludge is loaded underwater into small canisters. The small canisters are then transferred to the existing Fuel Transport System (FTS) where they are loaded underwater into the FTS Shielded Transfer Cask (STC). The STC is raised from the basin and placed into the Cask Transfer Overpack (CTO), loaded onto the trailer in the KW Basin Annex for transport to T Plant. At T Plant, the CTO is removed from the transport trailer and placed on the canyon deck. The CTO and STC are opened and the small canisters are removed using the canyon crane and placed into an STSC. The STSC is closed, and placed in storage arrays in the T Plant canyon cells for interim storage. The purpose of the cost estimate is to provide a comparison of the two concepts described.

GEUTHER J; CONRAD EA; RHOADARMER D

2009-08-24T23:59:59.000Z

230

Smard Grid Software Applications for Distribution Network Load Forecasting Eugene A. Feinberg, Jun Fei  

E-Print Network (OSTI)

of the distribution network. Keywords: load forecasting, feeder, transformer, load pocket, SmartGrid I. INTRODUCTION

Feinberg, Eugene A.

231

Distribution load study aids system planning  

SciTech Connect

The Walnut Metering Project is an experimental substation and distribution system metering installation designed to provide quantitative data for distribution system planning. The design and operation of the metering equipment are discussed. After 3 years of operation it was concluded that the primary economic benefits anticipated from the determination of substation area diversity characteristics did not materialize because the peaking characteristics of the substations in the area were typically coincident with each other. However, the data obtained had a significant positive impact, both economically and operationally, in the field of equipment loadability, and is beneficial to activities related to load projections and distribution system planning. (LCL)

Scofield J.M.

1976-07-01T23:59:59.000Z

232

DIELECTRIC-LOADED WAVE-GUIDES  

DOE Patents (OSTI)

This patent presents a particular arrangement for delectric loading of a wave-guide carrying an electromagnetic wave in the E or TM mode of at least the second order, to reduce the power dissipated as the result of conduction loss in the wave-guide walls. To achieve this desirabie result, the effective dielectric constants in the radial direction of adjacent coaxial tubular regions bounded approximateiy by successive nodai surfaces within the electromagnetic field are of two different values alternating in the radial direction, the intermost and outermost regions being of the lower value, and the dielectric constants between nodes are uniform.

Robertson-Shersby-Harvie, R.B.; Mullett, L.B.

1957-04-23T23:59:59.000Z

233

Analysis of parametric transformer with rectifier load  

SciTech Connect

This paper describes a push-pull parametric transformer constructed using a pair of orthogonal-cores. The operating characteristics of the parametric transformer with a rectifier load were analyzed based on SPICE simulations. The analysis results show good agreement with experiment. It was found that the input surge current of the full-wave rectifier circuit with a smoothing capacitor can be compensated by the parametric transformer. Use of the parametric transformer as a power stabilizer is anticipated owing to its various functions such as for voltage regulation and overload protection.

Ichinokura, O.; Jinzenji, T. (Tohoku Univ., Sendai (Japan)); Tajima, K. (Akita Univ. (Japan))

1993-03-01T23:59:59.000Z

234

Building Energy Software Tools Directory: HAP System Design Load  

NLE Websites -- All DOE Office Websites (Extended Search)

HAP System Design Load HAP System Design Load HAP System Design Load logo. Provides the load estimating and system design features found in its popular cousin � Carrier�s Hourly Analysis Program (HAP). By focusing on system design features, the HAP System Design Load program serves as a simpler, more efficient tool for those users only interested in system design; energy simulation features are omitted. Like the HAP program, HAP System Design Load provides the ease of use of a Windows-based graphical user interface and the computing power of modern 32-bit software. HAP System Design Load uses a system-based approach to HVAC load estimating. This approach tailors sizing procedures and results to the specific type of system being considered. A wide variety of equipment types

235

Crack coalescence in rock-like material under cycling loading  

E-Print Network (OSTI)

A total of 170 tests (68 tests for monotonic loading, 102 tests for cyclic loading) have been performed to investigate crack initiation, propagation and coalescence. The specimens have two pre-existing flaws which are ...

Ko, Tae Young, 1973-

2005-01-01T23:59:59.000Z

236

NREL: Vehicle Ancillary Loads Reduction - About the Project  

NLE Websites -- All DOE Office Websites (Extended Search)

same effect on fuel cell power sources of the future. The largest ancillary load is the air-conditioning system when it is operating. (Typically it imposes a mechanical load of...

237

Assessing and Reducing Miscellaneous Electric Loads (MELs) in Lodging  

SciTech Connect

Miscellaneous electric loads (MELs) are the loads outside of a building's core functions of heating, ventilating, air conditioning, lighting, and water heating. This report reviews methods to reduce MELs in lodging.

Rauch, Emily M.

2011-09-01T23:59:59.000Z

238

Dynamic load management for MMOGs in distributed environments  

Science Conference Proceedings (OSTI)

To support thousands of concurrent players in virtual worlds simulated by contemporary Massively Multiplayer Online Games, most implementations employ static game world partitioning for distributing the load among multiple game server instances. Further, ... Keywords: load balancing, mmogs

Herbert Jordan; Radu Prodan; Vlad Nae; Thomas Fahringer

2010-05-01T23:59:59.000Z

239

Load Profiling Based Routing for Guaranteed Bandwidth Flows  

E-Print Network (OSTI)

. To support the stringent Quality of Service (QoS) requirements of real-time (e.g. audio/video) applications in integrated services networks, several routing algorithms that allow for the reservation of the needed bandwidth over a Virtual Circuit (VC), established on one of several candidate routes, have been proposed. Traditionally, such routing is done using the least-loaded concept, and thus results in balancing the load across the set of candidate routes. In this paper, we propose the use of load profiling as an attractive alternative to load balancing for routing guaranteed bandwidth VCs (flows). Load profiling techniques allow the distribution of "available" bandwidth across a set of candidate routes to match the characteristics of incoming VC QoS requests. We thoroughly characterize the performance of VC routing using load profiling and contrast it to routing using load balancing and load packing. We do so both analytically and via extensive simulations of multi-class traffic r...

Ibrahim Matta; Azer Bestavros; Marwan Krunz

1999-01-01T23:59:59.000Z

240

deformation and failure of metals subjected to laser shock loading  

Science Conference Proceedings (OSTI)

The spall stress in laser pulse loading is much higher than in gas-gun loading because of the much ... Dynamic Contact Failure of Two Brittle Particles under Compression ... Natural Fiber Composite in a Novel Multi-Material Ballistic Armor.

Note: This page contains sample records for the topic "loading front loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Exploiting home automation protocols for load monitoring in smart buildings  

Science Conference Proceedings (OSTI)

Monitoring and controlling electrical loads is crucial for demand-side energy management in smart grids. Home automation (HA) protocols, such as X10 and Insteon, have provided programmatic load control for many years, and are being widely deployed in ...

David Irwin; Sean Barker; Aditya Mishra; Prashant Shenoy; Anthony Wu; Jeannie Albrecht

2011-11-01T23:59:59.000Z

242

A fuzzy logic based approach to direct load control  

SciTech Connect

Demand side management programs are strategies designed to alter the shape of the load curve. In order to successfully implement such a strategy, customer acceptance of the program is vital. It is thus desirable to design a model for direct load control which may accommodate customer preferences. This paper presents a methodology for optimizing both customer satisfaction and utility unit commitment savings, based on a fuzzy load model for the direct load control of appliances.

Bhattacharyya, K.; Crow, M.L. [Univ. of Missouri, Rolla, MO (United States). Dept. of Electrical Engineering

1996-05-01T23:59:59.000Z

243

Load Profiling and Settlement for Retail Markets Methods Assessment Study  

Science Conference Proceedings (OSTI)

Retail electric competition requires estimation of hourly loads for each retail supplier. Load profiling is the means by which loads for customers who do not have hourly metering are accounted for. This report presents an assessment of alternative load profiling and settlement methods for retail electric markets and provides a framework for evaluating costs and benefits of potential improvements to profiling and settlement systems. This report is available only to funders of Program 101A or 101.001. Fund...

1999-06-01T23:59:59.000Z

244

Load management strategies for electric utilities: a production cost simulation  

SciTech Connect

This paper deals with the development and application of a simulation model for analyzing strategies for managing the residential loads of electric utilities. The basic components of the model are (1) a production-cost model, which simulates daily operation of an electric power system; (2) a load model, which disaggregates system loads into appliance loads and other loads; and (3) a comparison model, which compares the production costs and energy consumption needed to meet a particular load profile to the corresponding costs and energy consumption required for another load profile. The profiles in each pair define alternative ways of meeting the same demand. A method for disaggregating load profiles into appliance components is discussed and several alternative strategies for residential load management for a typical northeastern electric utility are formulated. The method is based on an analysis of the composition of electric loads for a number of classes of residential customers in the model utility system. The effect of alternative load management strategies on the entire residential loadcurve is determined by predicting the effects of these strategies on the specific appliance components of the loadcurve. The results of using the model to analyze alternative strategies for residential load management suggest that load management strategies in the residential sector, if adopted by utilities whose operating and load characteristics are similar to those of the system modeled here, must take into account a wide variety of appliances to achieve significant changes in the total load profile. Moreover, the results also suggest that it is not easy to reduce costs significantly through new strategies for managing residential loads only and that, to be worthwhile, cost-reducing strategies will have to encompass many kinds of appliances.

Blair, P.D.

1979-03-01T23:59:59.000Z

245

Behavior of Laminate Reactive Materials under Dynamic Loading ...  

Science Conference Proceedings (OSTI)

Presentation Title, Behavior of Laminate Reactive Materials under Dynamic Loading ... Atomistically-Informed Dislocation Dynamics Simulations of High Rate  ...

246

Failure Prediction of Complex Structures Under Loading and ...  

loads; environmental corrosion is another significant stress factor. ... among different materials and how they exhibit crack growth. This method can ...

247

Spinning Reserve from Hotel Air Conditioning Load - SHORT VERSION  

SciTech Connect

Even though preliminary tests were not conducted during times of highest system or hotel loading during the summer, they showed that hotel load can be curtailed by 22 to 37 percent depending on the outdoor temperature and time of day. Full response occurred in 12 to 60 seconds from when the system operator's command to shed load was issued and the load drop was very rapid.

Kueck, John D [ORNL; Kirby, Brendan J [ORNL

2008-01-01T23:59:59.000Z

248

SAPHIRE 8 Volume 7 - Data Loading  

Science Conference Proceedings (OSTI)

The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) is a software application developed for performing a complete probabilistic risk assessment (PRA) using a personal computer. SAPHIRE Version 8 is funded by the U.S. Nuclear Regulatory Commission and developed by the Idaho National Laboratory. This report is intended to assist the user to enter PRA data into the SAPHIRE program using the built-in MAR-D ASCII-text file data transfer process. Towards this end, a small sample database is constructed and utilized for demonstration. Where applicable, the discussion includes how the data processes for loading the sample database relate to the actual processes used to load a larger PRA models. The procedures described herein were developed for use with SAPHIRE Version 8. The guidance specified in this document will allow a user to have sufficient knowledge to both understand the data format used by SAPHIRE and to carry out the transfer of data between different PRA projects.

K. J. Kvarfordt; S. T. Wood; C. L. Smith; S. R. Prescott

2011-03-01T23:59:59.000Z

249

A new approach applied to adaptive centralized load shedding scheme  

Science Conference Proceedings (OSTI)

One of major contingencies of an electric power system is due to imbalance between loads and generated power. This leads to instability in the power system and hence to a blackout. A load shedding scheme may be used to avoid such problem by reducing ... Keywords: adaptive load shedding scheme, critical power, power system, threshold power

Hamid Bentarzi; Abderrahmane Ouadi; Nadir Ghout; Farid Maamri; Nikos E. Mastorakis

2009-12-01T23:59:59.000Z

250

Model Based Load Indices (MBLI) for Scientific Stefan P. Muszala  

E-Print Network (OSTI)

Model Based Load Indices (MBLI) for Scientific Simulation by Stefan P. Muszala B.S., B.A. Rutgers and Computer Engineering 2008 #12;This thesis entitled: Model Based Load Indices (MBLI) for Scientific Engineering) Model Based Load Indices (MBLI) for Scientific Simulation Thesis directed by Dr. Daniel Connors

Colorado at Boulder, University of

251

Gravity Load Collapse of Building Frames during Earthquakes  

E-Print Network (OSTI)

Gravity Load Collapse of Building Frames during Earthquakes J. P. Moehle, K. J. Elwood, H. Sezen to frames designed primarily for gravity loads. Columns generally were not designed to have strengths capacity of the column. As the axial capacity diminishes, the gravity loads carried by the column must

Sezen, Halil

252

Dynamic modelling of metals - Time scales and target loads  

Science Conference Proceedings (OSTI)

Over the past decade steady-state methods have been developed to assess critical loads of metals avoiding long-term risks in view of food quality and eco-toxicological effects on organisms in soils and surface waters. However, dynamic models are needed ... Keywords: Critical loads, Delay times, Dynamic modelling, Metals, Scenario analysis, Target loads

Maximilian Posch; Wim de Vries

2009-01-01T23:59:59.000Z

253

Finite element modeling of transmission line under downburst wind loading  

Science Conference Proceedings (OSTI)

Despite the fact that extensive research has been carried out on transmission lines subjected to normal wind loads, their behaviour under high intensity wind loads (HIW), such as downburst, is poorly defined. This paper describes a detailed numerical ... Keywords: Downbursts, Finite element, Microbursts, Transmission line, Transmission tower, Wind load

A. Y. Shehata; A. A. El Damatty; E. Savory

2005-10-01T23:59:59.000Z

254

Variable Selection for Five-Minute Ahead Electricity Load Forecasting  

Science Conference Proceedings (OSTI)

We use autocorrelation analysis to extract 6 nested feature sets of previous electricity loads for 5-minite ahead electricity load forecasting. We evaluate their predictive power using Australian electricity data. Our results show that the most important ... Keywords: very short-term electricity load forecasting, prediction, variable selection, autocorrelation analysis

Irena Koprinska; Rohen Sood; Vassilios Agelidis

2010-08-01T23:59:59.000Z

255

Power load forecasting Organization: Huizhou Electric Power, P. R. China  

E-Print Network (OSTI)

, regression, artificial intelligence. 1. Introduction Accurate models for electric power load forecasting are essential to the operation and planning of a utility company. Load forecasting helps an electric utility as electric load forecasting. In particular, ARMA (autoregressive moving average), ARIMA (autore- gressive

256

Workload-Aware Load Balancing for Clustered Web Servers  

Science Conference Proceedings (OSTI)

We focus on load balancing policies for homogeneous clustered Web servers that tune their parameters on-the-fly to adapt to changes in the arrival rates and service times of incoming requests. The proposed scheduling policy, AdaptLoad, monitors the incoming ... Keywords: Clustered Web servers, self-managing clusters, load balance, locality awareness, workload characterization, static and dynamic pages.

Qi Zhang; Alma Riska; Wei Sun; Evgenia Smirni; Gianfranco Ciardo

2005-03-01T23:59:59.000Z

257

Commercial Nonintrusive Load Monitoring System Beta Test Results  

Science Conference Proceedings (OSTI)

Monitoring many different individual loads on customer premises is a costly, complex, and trouble-prone operation. The availability of a single instrument that could plug into the meter socket and measure individual premise loads would greatly simplify and reduce the cost of customer load monitoring. This report provides the test results of such a prototype instrument.

1999-12-15T23:59:59.000Z

258

Role of ponderomotive density modification in IBW loading  

SciTech Connect

We solve numerically a second-order nonlinear ordinary differential equation [1] that describes EPW-IBW mode transformation at the lower-hybrid layer, including self-consistent ponderomotive density profile modification, for the electrostatic potential in front of the IBW antenna. The model is solved for the particular case of heating just below the second harmonic of the deuterium cyclotron frequency. Background density and temperature profiles are chosen to be appropriate for the IBW experiments on TFTR. We calculate the complex antenna impedance, assuming vacuum within the antenna box, and a local reflectivity which reveal diminished antenna loading with increasing ponderomotive pressure, compared to the linear prediction. The ponderomotive force steepens the density gradient in the edge plasma, thus enhancing reflection and lowering the loading resistance. The model also describes the direct launch of IBWs in high edge density regimes, lacking a lower-hybrid layer, where the impedance is found to be much smaller than in the low density regime. {copyright} {ital 1997 American Institute of Physics.}

Russell, D.A.; Myra, J.R.; DIppolito, D.A. [Lodestar Research Corp., 2400 Central Ave. P-5, Boulder, Colorado 80301 (United States)

1997-04-01T23:59:59.000Z

259

On traffic load distribution and load balancing in dense wireless multihop networks  

Science Conference Proceedings (OSTI)

We study the load balancing problem in a dense wireless multihop network, where a typical path consists of a large number of hops, that is, the spatial scales of a typical distance between source and destination and mean distance between the neighboring ...

Esa Hyytiä; Jorma Virtamo

2007-01-01T23:59:59.000Z

260

Probability based load factors for design of concrete containment structures  

SciTech Connect

This paper describes a procedure for developing probability-based load combinations for the design of concrete containments. The proposed criteria are in a load and resistance factor design (LRFD) format. The load factors and resistance factors are derived for use in limit states design and are based on a target limit state probability. In this paper, the load factors for accident pressure and safe shutdown earthquake are derived for three target limit state probabilities. Other load factors are recommended on the basis of prior experience with probability-based design criteria for ordinary building construction. 6 refs.

Hwang, H.; Kagami, S.; Reich, M.; Ellingwood, B.; Shinozuka, M.

1985-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "loading front loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Estimation of structural reliability under combined loads. [PWR; BWR  

DOE Green Energy (OSTI)

For the overall safety evaluation of seismic category I structures subjected to various load combinations, a quantitative measure of the structural reliability in terms of a limit state probability can be conveniently used. For this purpose, the reliability analysis method for dynamic loads, which has recently been developed by the authors, was combined with the existing standard reliability analysis procedure for static and quasi-static loads. The significant parameters that enter into the analysis are: the rate at which each load (dead load, accidental internal pressure, earthquake, etc.) will occur, its duration and intensity. All these parameters are basically random variables for most of the loads to be considered. For dynamic loads, the overall intensity is usually characterized not only by their dynamic components but also by their static components. The structure considered in the present paper is a reinforced concrete containment structure subjected to various static and dynamic loads such as dead loads, accidental pressure, earthquake acceleration, etc. Computations are performed to evaluate the limit state probabilities under each load combination separately and also under all possible combinations of such loads.

Shinozuka, M.; Kako, T.; Hwang, H.; Brown, P.; Reich, M.

1983-01-01T23:59:59.000Z

262

DC switching regulated power supply for driving an inductive load  

DOE Patents (OSTI)

A power supply for driving an inductive load current from a dc power supply hrough a regulator circuit including a bridge arrangement of diodes and switching transistors controlled by a servo controller which regulates switching in response to the load current to maintain a selected load current. First and second opposite legs of the bridge are formed by first and second parallel-connected transistor arrays, respectively, while the third and fourth legs of the bridge are formed by appropriately connected first and second parallel connected diode arrays, respectively. The regulator may be operated in three "stages" or modes: (1) For current runup in the load, both first and second transistor switch arrays are turned "on" and current is supplied to the load through both transistor arrays. (2) When load current reaches the desired level, the first switch is turned "off", and load current "flywheels" through the second switch array and the fourth leg diode array connecting the second switch array in series with the load. Current is maintained by alternating between modes 1 and 2 at a suitable duty cycle and switching rate set by the controller. (3) Rapid current rundown is accomplished by turning both switch arrays "off", allowing load current to be dumped back into the source through the third and fourth diode arrays connecting the source in series opposition with the load to recover energy from the inductive load. The three operating states are controlled automatically by the controller.

Dyer, George R. (Norris, TN)

1986-01-01T23:59:59.000Z

263

NREL: Vehicle Ancillary Loads Reduction - Physiological Model  

NLE Websites -- All DOE Office Websites (Extended Search)

Physiological Model Physiological Model The Vehicle Ancillary Loads Reduction team developed a three-dimensional model to simulate human internal thermal physiological systems (muscle, blood, etc.) and thermoregulatory responses such as metabolic heat generation. The model was developed with ANSYS, a finite element software which computes heat flow by conduction, convection, and mass transport of the blood. A human tissue system model represents the human body, including the physiological and thermal properties of the tissues. The arms and legs consist of bone, muscle, fat, and skin. There are additional lung, abdominal, and brain tissues in the torso and head zones. The model calculates the conduction heat transfer based on the temperature gradients between the tissue nodes. Blood flow is modeled with a network of supply

264

Piezoelectric film load cell robot collision detector  

DOE Patents (OSTI)

A piezoelectric load cell which can be utilized for detecting collisions and obstruction of a robot arm end effector includes a force sensing element of metallized polyvinylidene fluoride (PVDF) film. The piezoelectric film sensing element and a resilient support pad are clamped in compression between upper and lower plates. The lower plate has a central recess in its upper face for supporting the support pad and sensing element, while the upper plate has a corresponding central projection formed on its lower face for bearing on the sensing element and support pad. The upper and lower plates are doweled together for concentric alignment and screwed together. The upper and lower plates are also adapted for mounting between the robot arm wrist and end effector. 3 figs.

Lembke, J.R.

1989-04-18T23:59:59.000Z

265

Piezoelectric film load cell robot collision detector  

DOE Patents (OSTI)

A piezoelectric load cell which can be utilized for detecting collisions and obstruction of a robot arm end effector includes a force sensing element of metallized polyvinylidene fluoride (PVDF) film. The piezoelectric film sensing element and a resilient support pad are clamped in compression between upper and lower plates. The lower plate has a central recess in its upper face for supporting the support pad and sensing element, while the upper plate has a corresponding central projection formed on its lower face for bearing on the sensing element and support pad. The upper and lower plates are dowelled together for concentric alignment and screwed together. The upper and lower plates are also adapted for mounting between the robot arm wrist and end effector. 3 figs.

Lembke, J.R.

1988-03-15T23:59:59.000Z

266

Active load control techniques for wind turbines.  

DOE Green Energy (OSTI)

This report provides an overview on the current state of wind turbine control and introduces a number of active techniques that could be potentially used for control of wind turbine blades. The focus is on research regarding active flow control (AFC) as it applies to wind turbine performance and loads. The techniques and concepts described here are often described as 'smart structures' or 'smart rotor control'. This field is rapidly growing and there are numerous concepts currently being investigated around the world; some concepts already are focused on the wind energy industry and others are intended for use in other fields, but have the potential for wind turbine control. An AFC system can be broken into three categories: controls and sensors, actuators and devices, and the flow phenomena. This report focuses on the research involved with the actuators and devices and the generated flow phenomena caused by each device.

van Dam, C.P. (University of California, Davis, CA); Berg, Dale E.; Johnson, Scott J. (University of California, Davis, CA)

2008-07-01T23:59:59.000Z

267

Building Energy Software Tools Directory: QwickLoad  

NLE Websites -- All DOE Office Websites (Extended Search)

QwickLoad QwickLoad QwickLoad logo QwickLoad uses the ASHRAE TFM (Transfer Function Method) algorithms combined with a screen interface that provides building load calculations. It includes a Duct Sizing Program and supports IP and SI units. QwickLoad Residential 7.0 provides heat gain and heat loss calculations for up to 10 zones. QwickLoad Commercial 7.0 provides heat gain and heat loss calculations for up to 500 zones. Zones and plenums can be added or deleted with one button click. Intuitive screens for entering building information. Default is automatically displayed. Construction types for roofs, walls, partitions, windows, shade types, and scheduling control. Complete air-conditioning and heating system control and supply, return, heating and cooling duct static pressure specification. Energy recovery ventilator can

268

Technical Assistance to ISO's and Grid Operators For Loads Providing  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Technical Assistance to ISO's and Grid Operators For Loads Technical Assistance to ISO's and Grid Operators For Loads Providing Ancillary Services To Enhance Grid Reliability Technical Assistance to ISO's and Grid Operators For Loads Providing Ancillary Services To Enhance Grid Reliability Project demonstrates and promotes the use of responsive load to provide ancillary services; helps ISOsand grid operators understand the resource and how best to apply it. Technical Assistance to ISO's and Grid Operators For Loads Providing Ancillary Services To Enhance Grid Reliability More Documents & Publications Loads Providing Ancillary Services: Review of International Experience 2012 Load as a Resource Program Peer Review New York Independent System Operator, Smart Grid RFI: Addressing Policy and Logistical Challenges.

269

Optimum matching of ohmic loads to the photovoltaic array  

SciTech Connect

Optimum matching of loads to the photovoltaic (PV) generator is most desirable for more accurate sizing, higher system performance and maximum utilization of the costly solar array generator. The quality of load matching depends on the PV array characteristics, the load characteristics, and the insolation profile. A matching factor is defined as the ratio of the load energy to the array maximum energy over a one day period. Optimum matching is achieved by determining the optimal array parameters with respect to the load parameters. Optimization is done using direct-search techniques. Results show that the theoretical optimum matching factor for an ohmic load is 94.34%. For an electrolytic load the matching factor could reach 99.83%. A maximum power tracker can be eliminated if optimum matching is achieved.

Khouzam, K.; Khouzam, L.; Groumpos, P. (Cleveland State Univ., OH (USA))

1991-01-01T23:59:59.000Z

270

Load Response Fundamentally Matches Power System Reliability Requirements  

Science Conference Proceedings (OSTI)

Responsive load is the most underutilized reliability resource available to the power system. Loads are frequently barred from providing the highest value and most critical reliability services; regulation and spinning reserve. Advances in communications and control technology now make it possible for some loads to provide both of these services. The limited storage incorporated in some loads better matches their response capabilities to the fast reliability-service markets than to the hourly energy markets. Responsive loads are frequently significantly faster and more accurate than generators, increasing power system reliability. Incorporating fast load response into microgrids further extends the reliability response capabilities that can be offered to the interconnected power system. The paper discusses the desired reliability responses, why this matches some loads' capabilities, what the advantages are for the power system, implications for communications and monitoring requirements, and how this resource can be exploited.

Kirby, Brendan J [ORNL

2007-01-01T23:59:59.000Z

271

High Dielectric Dummy Loads for ITER ICRH Antenna Laboratory Testing: Numerical Simulation of One Triplet Loading by Ferroelectric Ceramics  

SciTech Connect

Up to now, classical 'water' loads have been used for low power testing of ITER ICRH prototype or mock-up antennas . A fair description of the antenna frequency response is obtained excepted for the phasing (0 {pi} 0 {pi}). High dielectric loads are requested to improve the antenna response in the low frequency band. In view of laboratory testing, dummy loads are also required to have efficient wave spatial attenuation to avoid standing waves and to minimize load volume. In this paper, barium titanate ceramic powders mixed with water are shown to exhibit very attractive electromagnetic properties. Coupling performance of one triplet of the ITER ICRH antenna to such kind of loads is numerically investigated. The radiated wave attenuation into the load is also characterized. In spite of its frequency dispersion, 'barium titanate' loads are shown to allow the characterization of the full scale triplet frequency response on a scaled-down mock-up.

Champeaux, S.; Gouard, Ph. [CEA, DAM, DIF, F-91297 Arpajon (France); Bottollier-Curtet, H. [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France); Dumortier, P.; Koch, R.; Kyrytsya, V.; Messiaen, A. [Laboratory of Plasma Physics, Association EURATOM-Belgian State, Trilateral Euregio Cluster, Royal Military Academy, B-1000 Brussels (Belgium)

2011-12-23T23:59:59.000Z

272

An efficient load model for analyzing demand side management impacts  

SciTech Connect

The main objective of implementing Demand Side Management (DSM) in power systems is to change the utility's load shape--i.e. changes in the time pattern and magnitude of utility's load. Changing the load shape as a result of demand side activities could change the peak load, base load and/or energy demand. Those three variables have to be explicitly modeled into the load curve for properly representing the effects of demand side management. The impact of DSM will be manifested as higher or lower reliability levels. This paper presents an efficient technique to model the system load such that the impact of demand side management on the power system can be easily and accurately evaluated. The proposed technique to model the load duration curve will facilitate the representation of DSM impacts on loss-of-load probability, energy not served and energy consumption. This will provide an analytical method to study the impact of DSM on capacity requirements. So far iterative methods have been applied to study these impacts. The proposed analytical method results in a faster solution with higher accuracy. It takes only 18 seconds on an 80486 PC to solve each case study involving different peak and base loads, and energy use.

Rahman, S.; Rinaldy (Virginia Polytechnic Inst. and State Univ., Blacksburg, VA (United States))

1993-08-01T23:59:59.000Z

273

Dynamic model of power system operation incorporating load control  

SciTech Connect

Load management has been proposed as a means whereby an electric utility can reduce its requirements for additional generation, transmission, and distribution investments, shift fuel dependency from limited to more abundant energy resources, and improve the efficiency of the electric energy system. There exist, however, serious technological and economic questions which must be answered to define the cost trade-offs between initiating a load management strategy or adding additional capacity to meet the load. One aspect of this complex problem is to determine how the load profile might be modified by the load management option being considered. Towards this end, a model has been developed to determine how a power system with an active load control system should be operated to make the best use of its available resources. The model is capable of handling all types of conventional generating sources including thermal, hydro, and pumped storage units, and most appliances being considered for direct control including those with inherent or designed storage characteristics. The model uses a dynamic programming technique to determine the optimal operating strategy for a given set of conditions. The use of the model is demonstrated. Case study results indicate that the production cost savings that can be achieved through the use of direct load control are highly dependent on utility characteristics, load characteristics, storage capacity, and penetration. The load characteristics that produce the greatest savings are: large storage capacity; high coincidence with the system peak; large connected load per point; and moderately high diversity fraction.

Kuliasha, M.A.

1980-10-01T23:59:59.000Z

274

Testing a new direct load control power line communication system  

SciTech Connect

South Carolina Electric and Gas is currently performing direct load control communications over power lines without using a power line carrier. This is the result of testing a load management system that combines the existing substation solid-state recording with voltage regulation capability. Using the solid-state recorder's extended control functions, the existing substation tap changer, a new patent-pending power line communications technique, and a patented voltage-step load control receiver, the system extends normal two-way communication between the utility operations and the substation with a one-way power line link to virtually any load. By varying the voltage level slightly, the system digitizes up to 32 different load control messages. The new voltage-step communication technique uses the substation's load tap changer to communicate one-way with the receivers over existing power lines. South Carolina Electric and Gas and the manufacturers have been performing a two-phase test of the load control system. Phase one testing showed that the percentage of successful load control message reception was 98%. Phase two testing is still in progress. Results to date show no deterioration of reception or equipment. Conclusions thus far are that the load management system is compatible with all installed utility equipment, and offers reliable direct load control.

Weers, D.D.; Shamsedin, M.A.

1987-07-01T23:59:59.000Z

275

Decomposition of Rare Earth Loaded Resin Particles  

Science Conference Proceedings (OSTI)

The Fuel Cycle R and D (FCR and D) program within the Department of Energy Office of Nuclear Energy (DOE-NE) is evaluating nuclear fuel cycle options, including once-through, modified open, and fully closed cycles. Each of these scenarios may utilize quite different fuel management schemes and variation in fuel types may include high thermal conductivity UO{sub 2}, thoria-based, TRISO, metal, advanced ceramic (nitride, carbide, composite, etc.), and minor actinide (MA) bearing fuels and targets. Researchers from the US, Europe, and japan are investigating methods of fabricating high-specific activity spherical particles for fuel and target applications. The capital, operating, and maintenance costs of such a fuel fabrication facility can be significant, thus fuel synthesis and fabrication processes that minimize waste and process losses, and require less footprint are desired. Investigations have been performed at the Institute for Transuranium Elements (ITU) and the French Atomic Energy Commission (CEA) studying the impact of americium and curium on the fuel fabrication process. proof of concept was demonstrated for fabrication of MA-bearing spherical particles, however additional development will be needed for engineering scale-up. Researchers at the Paul Scherer Institute (PSI) and the Japan Atomic Energy Association (JAEA) have collaborated on research with ceramic-metallic (CERMET) fuels using spherical particles as the ceramic component dispersed in the metal matrix. Recent work at the CEA evaluates the burning of MA in the blanket region of sodium fast reactors. There is also interest in burning MA in Canada Deuterium Uranium (CANDU) reactors. The fabrication of uranium-MA oxide pellets for a fast reactor blanket or MA-bearing fuel for CANDU reactors may benefit from a low-loss dedicated footprint for producing MA-spherical particles. One method for producing MA-bearing spherical particles is loading the actinide metal on a cation exchange resin. The AG-50W resin is made of sulfonic acid functional groups attached to a styrene divinylbenzene copolymer lattice (long chained hydrocarbon). The metal cation binds to the sulfur group, then during thermal decomposition in air the hydrocarbons will form gaseous species leaving behind a spherical metal-oxide particle. Process development for resin applications with radioactive materials is typically performed using surrogates. For americium and curium, a trivalent metal like neodymium can be used. Thermal decomposition of Nd-loaded resin in air has been studied by Hale. Process conditions were established for resin decomposition and the formation of Nd{sub 2}O{sub 3} particles. The intermediate product compounds were described using x-ray diffraction (XRD) and wet chemistry. Leskela and Niinisto studied the decomposition of rare earth (RE) elements and found results consistent with Hale. Picart et al. demonstrated the viability of using a resin loading process for the fabrication of uranium-actinide mixed oxide microspheres for transmutation of minor actinides in a fast reactor. For effective transmutation of actinides, it will be desirable to extend the in-reactor burnup and minimize the number of recycles of used actinide materials. Longer burn times increases the chance of Fuel Clad Chemical or Mechanical Interaction (FCCI, FCMI). Sulfur is suspected of contributing to Irradiation Assisted Stress Corrosion Cracking (IASCC) thus it is necessary to maximize the removal of sulfur during decomposition of the resin. The present effort extends the previous work by quantifying the removal of sulfur during the decomposition process. Neodymium was selected as a surrogate for trivalent actinide metal cations. As described above Nd was dissolved in nitric acid solution then contacted with the AG-50W resin column. After washing the column, the Nd-resin particles are removed and dried. The Nd-resin, seen in Figure 1 prior to decomposition, is ready to be converted to Nd oxide microspheres.

Voit, Stewart L [ORNL; Rawn, Claudia J [ORNL

2010-09-01T23:59:59.000Z

276

Regression Models for Demand Reduction based on Cluster Analysis of Load Profiles  

E-Print Network (OSTI)

on Cluster Analysis of Load Profiles Nobuyuki Yamaguchi,on Cluster Analysis of Load Profiles Nobuyuki Yamaguchi,regressions, using actual load profile data of Pacific Gas

Kiliccote, Sila

2010-01-01T23:59:59.000Z

277

WECS - load controlled pitch - variable load conversion to heat. Final report  

SciTech Connect

Load control circuitry was developed such that excess energy from a windmill, that would normally go back to the utility, be absorbed in thermal storage to heat domestic hot water. Also, associated with this objective is the development of instrumentation to measure the power curve of the windmill as a function of windspeed. An Enertech 4KW windmill and related equipment was used to meet this objective.

Secord, N.

1983-11-26T23:59:59.000Z

278

Commercial equipment loads: End-Use Load and Consumer Assessment Program (ELCAP)  

SciTech Connect

The Office of Energy Resources of the Bonneville Power Administration is generally responsible for the agency's power and conservation resource planning. As associated responsibility which supports a variety of office functions is the analysis of historical trends in and determinants of energy consumption. The Office of Energy Resources' End-Use Research Section operates a comprehensive data collection program to provide pertinent information to support demand-side planning, load forecasting, and demand-side program development and delivery. Part of this on-going program is known as the End-Use Load and Consumer Assessment Program (ELCAP), an effort designed to collect electricity usage data through direct monitoring of end-use loads in buildings. This program is conducted for Bonneville by the Pacific Northwest Laboratory. This report provides detailed information on electricity consumption of miscellaneous equipment from the commercial portion of ELCAP. Miscellaneous equipment includes all commercial end-uses except heating, ventilating, air conditioning, and central lighting systems. Some examples of end-uses covered in this report are office equipment, computers, task lighting, refrigeration, and food preparation. Electricity consumption estimates, in kilowatt-hours per square food per year, are provided for each end-use by building type. The following types of buildings are covered: office, retail, restaurant, grocery, warehouse, school, university, and hotel/motel. 6 refs., 35 figs., 12 tabs.

Pratt, R.G.; Williamson, M.A.; Richman, E.E.; Miller, N.E.

1990-07-01T23:59:59.000Z

279

Apparatus for loading shape memory gripper mechanisms  

SciTech Connect

A method and apparatus for loading deposit material, such as an embolic coil, into a shape memory polymer (SMP) gripping/release mechanism. The apparatus enables the application of uniform pressure to secure a grip by the SMP mechanism on the deposit material via differential pressure between, for example, vacuum within the SMP mechanism and hydrostatic water pressure on the exterior of the SMP mechanism. The SMP tubing material of the mechanism is heated to above the glass transformation temperature (Tg) while reshaping, and subsequently cooled to below Tg to freeze the shape. The heating and/or cooling may, for example, be provided by the same water applied for pressurization or the heating can be applied by optical fibers packaged to the SMP mechanism for directing a laser beam, for example, thereunto. At a point of use, the deposit material is released from the SMP mechanism by reheating the SMP material to above the temperature Tg whereby it returns to its initial shape. The reheating of the SM material may be carried out by injecting heated fluid (water) through an associated catheter or by optical fibers and an associated beam of laser light, for example.

Lee, Abraham P. (Walnut Creek, CA); Benett, William J. (Livermore, CA); Schumann, Daniel L. (Concord, CA); Krulevitch, Peter A. (Pleasanton, CA); Fitch, Joseph P. (Livermore, CA)

2001-01-01T23:59:59.000Z

280

Lithium Loaded Glass Fiber Neutron Detector Tests  

Science Conference Proceedings (OSTI)

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world and, thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. Reported here are the results of tests of the lithium-loaded glass fibers option. This testing measured the neutron detection efficiency and gamma ray rejection capabilities of a small system manufactured by Nucsafe (Oak Ridge, TN).

Ely, James H.; Erikson, Luke E.; Kouzes, Richard T.; Lintereur, Azaree T.; Stromswold, David C.

2009-11-12T23:59:59.000Z

Note: This page contains sample records for the topic "loading front loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

DSM Load Growth Through Electrotechnology Application Assistance  

E-Print Network (OSTI)

This paper will discuss how a new "win-win" approach is emerging that improves both customer competitiveness and utility energy sales as both DSM and the utility's relationship with its customers mature. While most DSM resources have been invested in conservation efforts, the efficient load building aspects must no longer be ignored. As DSM "returns to its roots," electrotechnology applications assistance programs are beginning to provide measured results that are a key part of utility efforts to manage demand. Several innovative electrotechnology application programs exist but most share a combination of the following key attributes: 1) Immediate results-oriented electrotechnology applications assistance and implementation is provided to key customers, 2) Market research is conducted on a broad category of customers to determine appropriate electrotechnology applications and assistance, 3) An advertising and promotional campaign development/ implementation plan is created, 4) Technology transfer training is provided for customers and utility staff, and 5) An assessment is made for the development of a regional technology application center.

Merchant, D. G.

1994-04-01T23:59:59.000Z

282

scriptEnv - loading modules before starting a script  

NLE Websites -- All DOE Office Websites (Extended Search)

scriptEnv - loading modules before starting a script scriptEnv - loading modules before starting a script scriptEnv - loading modules before starting a script In some cases a script needs to load modules before the script can be executed, but it can often be inconvenient or impossible to provide wrapper scripts which load the needed modules. CGI scripts on the gpweb resources or in the NERSC portal environment which require the genepool-specific python/perl/R or databases configuration modules are a strong example of this. NERSC provides the scriptEnv as a custom drop-in replacement for /usr/bin/env. scriptEnv loads your selected modules to allow your scripts to run easily and reproducibly. After constructing your scriptEnv, you only need replace the shebang line of your script to use your custom scriptEnv

283

Load Balancing Of Parallel Monte Carlo Transport Calculations  

National Nuclear Security Administration (NNSA)

Load Balancing Of Parallel Load Balancing Of Parallel Monte Carlo Transport Calculations R.J. Procassini, M. J. O'Brien and J.M. Taylor Lawrence Livermore National Laboratory, P. O. Box 808, Livermore, CA 94551 The performance of parallel Monte Carlo transport calculations which use both spatial and particle parallelism is increased by dynamically assigning processors to the most worked domains. Since the particle work load varies over the course of the simulation, each cycle this algorithm determines if dynamic load balancing would speed up the calculation. If load balancing is required, a small number of particle communications are initiated in order to achieve load balance. This method has decreased the parallel run time by more than a factor of three for certain criticality

284

Cementitious Stabilization of Mixed Wastes with High Salt Loadings  

SciTech Connect

Salt loadings approaching 50 wt % were tolerated in cementitious waste forms that still met leach and strength criteria, addressing a Technology Deficiency of low salt loadings previously identified by the Mixed Waste Focus Area. A statistical design quantified the effect of different stabilizing ingredients and salt loading on performance at lower loadings, allowing selection of the more effective ingredients for studying the higher salt loadings. In general, the final waste form needed to consist of 25 wt % of the dry stabilizing ingredients to meet the criteria used and 25 wt % water to form a workable paste, leaving 50 wt % for waste solids. The salt loading depends on the salt content of the waste solids but could be as high as 50 wt % if all the waste solids are salt.

Spence, R.D.; Burgess, M.W.; Fedorov, V.V.; Downing, D.J.

1999-04-01T23:59:59.000Z

285

Statistical Review of UK Residential Sector Electrical Loads  

E-Print Network (OSTI)

This paper presents a comprehensive statistical review of data obtained from a wide range of literature on the most widely used electrical appliances in the UK residential load sector. It focuses on individual appliances and begins by consideration of the electrical operations performed by the load. This approach allows for the loads to be categorised based on the electrical characteristics, and also provides information on the reactive power characteristics of the load, which is often neglected from standard consumption statistics. This data is particularly important for power system analysis. In addition to this, device ownership statistics and probability distribution functions of power demand are presented for the main residential loads. Although the data presented is primarily intended as a resource for the development of load profiles for power system analysis, it contains a large volume of information which provides a useful database for the wider research community.

Tsagarakis, G; Kiprakis, A E

2013-01-01T23:59:59.000Z

286

Forecasting distribution system loads using curve shape clustering  

SciTech Connect

Trending using curve fitting to past small area load growth is an economical but not highly accurate method of forecasting loads for distribution planning. A new trending method uses clustering of historical load at the small area level as the forecast algorithm. This new method has significant performance advantages over normal curve fit methods and can be implemented in 16 bit integer arithmetic on most computers. The method and test results are discussed in detail.

Willis, H.L.; Northcote-Green, J.E.D.; Schauer, A.E.; Vismor, T.D.

1983-04-01T23:59:59.000Z

287

STLOAD 1.1 (Substation Terminal Equipment Loading Software)  

Science Conference Proceedings (OSTI)

EPRI’s Substation Terminal Equipment Loading software (STLOAD 1.1) calculates temperatures and thermal ratings for substation equipment based on physical parameters of the equipment, electrical load, air temperature, and, where appropriate, solar heating and wind. This provides a convenient way for substation engineers to maximize the usage of existing substation terminal equipment under a wide variety of operating conditions. STLOAD can perform temperature and rating calculations for a daily load and am...

2009-04-06T23:59:59.000Z

288

Using DER in Transmission-Constrained Urban Load Pockets  

Science Conference Proceedings (OSTI)

Urban load centers are characterized by their dense population, environmental constraints, as well as transmission-constrained electricity delivery. They also have potentially high infrastructure investment costs for distribution system investments to meet peak load growth. This report looks at seven areas in the United States that have been identified as transmission-constrained load pockets, focusing on opportunities for using distributed energy resources (DER).

2007-12-17T23:59:59.000Z

289

Extracting Operating Modes from Building Electrical Load Data: Preprint  

Science Conference Proceedings (OSTI)

Empirical techniques for characterizing electrical energy use now play a key role in reducing electricity consumption, particularly miscellaneous electrical loads, in buildings. Identifying device operating modes (mode extraction) creates a better understanding of both device and system behaviors. Using clustering to extract operating modes from electrical load data can provide valuable insights into device behavior and identify opportunities for energy savings. We present a fast and effective heuristic clustering method to identify and extract operating modes in electrical load data.

Frank, S.; Polese, L. G.; Rader, E.; Sheppy, M.; Smith, J.

2012-01-01T23:59:59.000Z

290

End-Use Load Composition Estimation Using Smart Meter Data  

Science Conference Proceedings (OSTI)

The goal of this research project is to enhance methodologies used to compute the fraction of load components (that is, motor; constant impedance, constant current, and constant power (ZIP); and electronic) needed for power system simulations that are attributable to each load class (that is, residential, commercial, industrial, and agricultural) by using smart meter (advanced metering infrastructure [AMI]) data. The load component percentages obtained should be appropriate for an overall component-based...

2010-12-31T23:59:59.000Z

291

Electrical Energy Conservation and Load Management - An Industrial User's Viewpoint  

E-Print Network (OSTI)

Conservation of electrical energy and load management can reduce industry's electric bills, conserves natural resources and reduces the need for new generating plants. In recent years, industry has implemented extensive conservation programs. Some load management has been implemented already. Additional load management is possible; however, optimizing it will require close industry and electric utility company cooperation to develop new incentives and rate structures to make it economically attractive. The limitations of existing rate structures and needed improvements are presented.

Jackson, C. E.

1984-01-01T23:59:59.000Z

292

Bubble deaeration of water at reduced unit loads  

Science Conference Proceedings (OSTI)

Whenever the load is reduced, the parameters of the water and steam being introduced into the deaerator, as well as the pressure, also change. A study was conducted to ascertain the reasons for the improvement in water deaeration whenever the unit load is reduced. The study of the deaerator demonstrated that reducing the load on the turbine produces a reduction in the amount of oxygen contained in the feedwater from 25-30 to 8-12 ..mu..g/kg.

Kondrat'ev, A.D.; Kurnyk, L.N.

1982-11-01T23:59:59.000Z

293

Load Following in Geothermal Plants: Capabilities and Challenges  

Science Conference Proceedings (OSTI)

Typically, geothermal power plants are baseload facilities, but they may be operated in a load-following mode in the same manner as conventional steam plants. As grid penetration of renewable resources increases - especially those generation types with diurnal variations such as wind and solar - the ability of other power plants to load-follow becomes increasingly valuable.Load following is challenging in terms of the design, operations, and maintenance of flash and binary geothermal ...

2013-08-22T23:59:59.000Z

294

Strategy Guideline: Accurate Heating and Cooling Load Calculations  

SciTech Connect

This guide presents the key criteria required to create accurate heating and cooling load calculations and offers examples of the implications when inaccurate adjustments are applied to the HVAC design process. The guide shows, through realistic examples, how various defaults and arbitrary safety factors can lead to significant increases in the load estimate. Emphasis is placed on the risks incurred from inaccurate adjustments or ignoring critical inputs of the load calculation.

Burdick, A.

2011-06-01T23:59:59.000Z

295

Cooling load differences between radiant and air systems  

E-Print Network (OSTI)

the effect of thermal mass on cooling loads, and thereforelift radiant cooling using building thermal mass, Departmentlevel thermal modelling are recommended for design cooling

Feng, Jingjuan Dove; Schiavon, Stefano; Bauman, Fred

2013-01-01T23:59:59.000Z

296

California Customer Load Reductions during the Electricity Crisis...  

Open Energy Info (EERE)

California Customer Load Reductions during the Electricity Crisis: Did They Help to Keep the Lights On? Jump to: navigation, search Tool Summary LAUNCH TOOL Name: California...

297

Loads Providing Ancillary Services: Review of International Experience...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

LaaR Load Acting as a Resource (Texas) LMP Locational Marginal Price MCPE Market Clearing Price of Energy (Texas) NCAS Network Control Ancillary Services (Australia) NGC National...

298

Demand response can lower electric power load when needed - Today ...  

U.S. Energy Information Administration (EIA)

February 15, 2011 Demand response can lower electric power load when needed . Consumers can play a major role in ensuring reliable electricity supply by reducing ...

299

Adaptive load control of microgrids with non-dispatchable generation.  

E-Print Network (OSTI)

??Intelligent appliances have a great potential to provide energy storage and load shedding for power grids. Microgrids are simulated with high levels of wind energy… (more)

Brokish, Kevin Martin

2009-01-01T23:59:59.000Z

300

Methods and apparatus for reducing peak wind turbine loads ...  

A method for reducing peak loads of wind turbines in a changing wind environment includes measuring or estimating an instantaneous wind speed and direction at the ...

Note: This page contains sample records for the topic "loading front loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Loaded Transmission Error Measurement System for Spur and Helical Gears.  

E-Print Network (OSTI)

??The majority of loaded static transmission error test stands developed in the past had little success generating accurate results versus analytical predictions for parallel-axis gearing.… (more)

Wright, Zachary Harrison

2009-01-01T23:59:59.000Z

302

HVAC Loads in High-Performance Homes (Presentation)  

SciTech Connect

This presentation was delivered at the ASHRAE 2010 Annual Summer Conference on June 27, 2010, and addresses humidity and AC loads in energy efficient houses.

Christensen, D.; Fang, X.; Winkler, J.

2010-06-27T23:59:59.000Z

303

ENERGY STAR Building Upgrade Manual Chapter 7: Supplemental Load...  

NLE Websites -- All DOE Office Websites (Extended Search)

care resources Small business resources State and local government resources ENERGY STAR Building Upgrade Manual Chapter 7: Supplemental Load Reduction The Building Upgrade...

304

Definition: Generator-To-Load Distribution Factor | Open Energy...  

Open Energy Info (EERE)

on an identified transmission facility or Flowgate.1 Related Terms Load Shift Factor, transmission lines, Generator Shift Factor, transmission line, flowgate, smart grid...

306

ELECTRICAL LOAD MANAGEMENT FOR THE CALIFORNIA WATER SYSTEM  

E-Print Network (OSTI)

of Water Resources. Water Conservation in California. DWRUse ENERGY CONSERVATION Water Conservation Pump Efficienciescussion of load Water Conservation some of these measures in

Krieg, B.

2010-01-01T23:59:59.000Z

307

Unit load and material handling considerations in facility layout design  

E-Print Network (OSTI)

Dec 1, 2002 ... In this paper, the integration of unit load and material handling considerations in facility layout design is presented. This integration is based on ...

308

Dynamic response of fixed offshore platforms to environmental loads.  

E-Print Network (OSTI)

??In this thesis a simplified method for dynamic response of jacket type offshore structures to extreme environmental load is investigated using existing experience and the… (more)

Azarhoushang, Azin

2010-01-01T23:59:59.000Z

309

Capacity Assessment of a Transmission Tower under Wind Loading.  

E-Print Network (OSTI)

??Transmission towers play a vital role in power distribution networks and are often subject to strong wind loads. Lattice tower design is often based on… (more)

Mara, Thomas G

2013-01-01T23:59:59.000Z

310

Automated Load Balancing of Medium-Voltage Distribution Circuits  

Science Conference Proceedings (OSTI)

The objective of this project is to investigate the possibility of using an automated system to maintain optimal load balance in distribution circuits. The practice used by many utilities is to use a line crew and engineering personnel to measure load balance at key points in each circuit and manually move single-phase lateral taps to different phases to obtain the desired load balance among the phases. This practice has many shortcomings: The load balance is achieved only for a single point in ...

2013-03-21T23:59:59.000Z

311

NREL Develops Simulations for Wind Plant Power and Turbine Loads...  

NLE Websites -- All DOE Office Websites (Extended Search)

loading due to wake turbulence. The current state of knowledge concerning wind turbine wakes and how they interact with other turbines and the atmospheric boundary layer is...

312

Peak load control energy saving and cycling system  

SciTech Connect

A control system for limiting peak load demand and/or saving electrical energy by cycling the individual loads within an electrical distribution system is described. Electrical power usage in a distribution system is continuously monitored and compared to a pre-set limit. Loads can be added and cycled according to a limit set by the operator. Loads can also be dropped in response to a signal proportional to the electrical power usage in a distribution system within limits defined by the operator.

Burch, J.

1976-10-19T23:59:59.000Z

313

Non-Intrusive Load Monitoring (NILM)Technologies for End-Use Load Disaggregation: Laboratory Evaluation I  

Science Conference Proceedings (OSTI)

This report presents the results of a laboratory evaluation to assess the cost versus accuracy performance of residential non-intrusive load monitoring (NILM) technology. NILM is an evolving technology that can be deployed for utility and customer applications, such as end-use load disaggregation, energy audits, real-time customer information and appliance or load diagnostics. Commercial NILM products for utility and customer applications continue to emerge, although most products available today ...

2013-05-22T23:59:59.000Z

314

Improved load ratio method for predicting crack length  

SciTech Connect

The elastic compliance from unloading/reloading sequences in a load-displacement record estimates well crack length in elastic-plastic fracture toughness tests of compact tension [C(T)] and bending type specimens. The need for partial unloading of the specimen makes it difficult to run the test under static loading and impossible under either dynamic loading or very high temperatures. Furthermore, fracture toughness testing in which crack length is determined from elastic compliance requires high precision testing equipment and highly skilled technicians. As a result, such tests are confined usually to research laboratories and seldom used under production settings. To eliminate these problems, an improved load ratio method of predicting crack length is proposed that utilizes only the recorded load versus load-line displacement curve (or load versus crack-mouth-opening displacement curve) without unloading/reloading sequences. As a result, the instrumentation is much simpler than in the elastic compliance or potential drop methods. If only a monotonic load-displacement record is to be measured the fracture toughness test becomes almost as simple to perform as a tension test. The method described here improves in three ways the ``original load ratio method`` proposed by Hu et al. First, a blunting term is added to the crack length before maximum load. Second, a strain hardening correction is included after maximum load. And, third, the initial crack length and the physical (final) crack length measured at the end of the test serve to anchor the predicted crack lengths, forcing agreement between predicted and measured values. The method predicts crack extension with excellent accuracy in specimens fabricated from A302, A508, and A533B piping and pressure vessel steels, A588 and A572 structural steels, and HY-80 ship steel.

Chen, X.; Albrecht, P. [Univ. of Maryland, College Park, MD (United States). Inst. for Systems Research; Wright, W. [Federal Highway Administration, McLean, VA (United States). Turner-Fairbank Highway Research Center; Joyce, J.A. [Naval Academy, Annapolis, MD (United States). Mechanical Engineering Dept.

1995-04-01T23:59:59.000Z

315

Load management and the La Vereda passive solar community  

SciTech Connect

Reviewed are preliminary data available from some of the passive solar homes now operational at the La Vereda subdivision in Santa Fe, New Mexico. The major emphasis is Load Management - an electric utility term pertaining to when and how much energy is used by the customer. A customer's home is considered to be Load Managed when its major demands for electricity occur at times during the day when the utility has surplus generation capacity. For most utilities this surplus occurs during the night and is referred to as the off-peak period. Compared to conventional electric homes, the La Vereda passive solar homes are Naturally Load Managed because most of their backup heating requirements occur during the utility's off-peak period. Naturally Load Managed homes like these allow the backup heating system to operate freely whenever the space needs heat. Load data from six La Vereda homes are compared to similar data from 1) a group of nonsolar super-insulated total electric homes, and 2) the utility's winter system peak day load profile. The comparison verifies the Natural Load Management characteristics of the well-designed passive solar home. The free operation of the backup heating system, especially during cloudy or severe weather, can reduce the Natural Load Management characteristics of the La Verda homes. Is it possible to Force Load Management on a home, regardless of weather conditions and still guarantee that all space heating requirements are satisfied with off-peak energy. One home at La Vereda is discussed that has an experimental Forced Load Management backup heating system designed to use energy only during the utility's off-peak period. Load data from this home is presented and compared to other homes at La Verda.

Pyde, S.E.

1981-01-01T23:59:59.000Z

316

Mirant: Case 67a: Units 3 & 4 & 5 at Max Load for 12 hours and at Min Load  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Mirant: Case 67a: Units 3 & 4 & 5 at Max Load for 12 hours and at Mirant: Case 67a: Units 3 & 4 & 5 at Max Load for 12 hours and at Min Load for 12 hours Mirant: Case 67a: Units 3 & 4 & 5 at Max Load for 12 hours and at Min Load for 12 hours Docket No. EO-05-01. Mirant: Case 67a: Units 3 & 4 & 5 at Max Load for 12 hours and at Min Load for 12 hours. Arial photograph showing plant and location of predicted SO2 violations, predicted in 2000. Mirant: Case 67a: Units 3 & 4 & 5 at Max Load for 12 hours and at Min Load for 12 hours More Documents & Publications Mirant Potomac, Alexandria, Virginia: Maximum Impacts Predicted by AERMOD-PRIME, Units 3, 1, 2 SO2 Case Mirant Potomac, Alexandria, Virginia: Maximum Impacts Predicted by AERMOD-PRIME, Units 4, 1, 2 SO2 Case Mirant Potomac, Alexandria, Virginia: Maximum Impacts Predicted by

317

Estimating Demand Response Load Impacts: Evaluation of Baseline Load Models for Non-Residential Buildings in California  

E-Print Network (OSTI)

Protocols  for  Demand  Response  Load  Impacts  Estimates, Potter  2006.     The  Demand  Response Baseline, v.1.75.   Assessment  of  Demand  Response  and  Advanced  Metering, 

Coughlin, Katie; Piette, Mary Ann; Goldman, Charles; Kiliccote, Sila

2008-01-01T23:59:59.000Z

318

Report of the US Nuclear Regulatory Commission Piping Review Committee. Volume 4. Evaluation of other loads and load combinations  

SciTech Connect

Six topical areas were covered by the Task Group on Other Dynamic Loads and Load Combinations as described below: Event Combinations - dealing with the potential simultaneous occurrence of earthquakes, pipe ruptures, and water hammer events in the piping design basis; Response Combinations - dealing with multiply supported piping with independent inputs, the sequence of combinations between spacial and modal components of response, and the treatment of high frequency modes in combination with low frequency modal responses; Stress Limits/Dynamic Allowables - dealing with inelastic allowables for piping and strain rate effects; Water Hammer Loadings - dealing with code and design specifications for these loadings and procedures for identifying potential water hammer that could affect safety; Relief Valve Opening and Closing Loads - dealing with the adequacy of analytical tools for predicting the effects of these events and, in addition, with estimating effective cycles for fatigue evaluations; and Piping Vibration Loads - dealing with evaluation procedures for estimating other than seismic vibratory loads, the need to consider reciprocating and rotary equipment vibratory loads, and high frequency vibratory loads. NRC staff recommendations or regulatory changes and additional study appear in this report.

Not Available

1984-12-01T23:59:59.000Z

319

Analytical and demonstration experience with changing load profile. Final report  

SciTech Connect

A bibliography of load management and supply management projects, sponsored by EPRI, was developed. Summaries of project scope and results were made for a selection of these projects already completed. Finally, summaries of six utility load management demonstration projects were made, including project descriptions and presentation of selected results.

Isaksen, L.; Khan, S.; Ma, F.S.

1979-12-01T23:59:59.000Z

320

Air Conditioning Load Prediction Based on DE-SVM Algorithm  

Science Conference Proceedings (OSTI)

Based on SVM (Support Vector Machine) theory, and the model to predict air conditioning load was established. In order to optimize the behavior of SVM, the DE (Differential Evolution) algorithm was introduced into classic SVM. The DE-SVM model is applied ... Keywords: Air Conditioning load, DE-SVM, Prediction

Zhonghai Chen; Yong Sun; Guoli Yang; Tengfei Wu; Guizhu Li; Longbiao Xin

2010-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "loading front loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Impact of Nonlinear Loads on Motor Generator Sets  

Science Conference Proceedings (OSTI)

Using backup generators with loads that create high harmonics can cause power quality problems. This report describes how to calculate voltage distortion based on the different impedance characteristics of a generator and the harmonic current characteristics of loads and discusses options for reducing the harmonics and mitigating their impact.

2001-10-29T23:59:59.000Z

322

Supplying Renewable Energy to Deferrable Loads: Algorithms and Economic Analysis  

E-Print Network (OSTI)

Supplying Renewable Energy to Deferrable Loads: Algorithms and Economic Analysis Anthony in order to mitigate the unpredictable and non-controllable fluctuation of renewable power supply. We cast for optimally supplying renewable power to time-flexible electricity loads in the presence of a spot market

Oren, Shmuel S.

323

A Load Balancing Tool for Distributed Parallel Loops  

Science Conference Proceedings (OSTI)

Large scale applications typically contain parallel loops with many iterates. The iterates of a parallel loop may have variable execution times which translate into performance degradation of an application due to load imbalance. This paper describes ... Keywords: adaptive loop scheduling, dynamic load balancing

Ricolindo L. Cariño; Ioana Banicescu

2005-10-01T23:59:59.000Z

324

Dynamic load balancing with adaptive factoring methods in scientific applications  

Science Conference Proceedings (OSTI)

To improve the performance of scientific applications with parallel loops, dynamic loop scheduling methods have been proposed. Such methods address performance degradations due to load imbalance caused by predictable phenomena like nonuniform data distribution ... Keywords: Adaptive weighted factoring, Dynamic load balancing

Ricolindo L. Cariño; Ioana Banicescu

2008-04-01T23:59:59.000Z

325

Detection of Periodic Beacon Loads in Electrical Distribution Substation Data  

Science Conference Proceedings (OSTI)

This research explores methods for identifying a whether a load is sending a signal to the utility SCADA system. Such a system can identify whether various loads are signialing using existing SCADA infrastructure, that is, without added, high cost communications infrastructure.

Hammerstrom, Donald J.; Guttromson, Ross T.; Lu, Ning; Boyd, Paul A.; Trudnowski, Daniel; Chassin, David P.; Bonebrake, Christopher A.; Shaw, James M.

2006-05-31T23:59:59.000Z

326

Investigation of Residential Central Air Conditioning Load Shapes in  

E-Print Network (OSTI)

LBNL-52235 Investigation of Residential Central Air Conditioning Load Shapes in NEMS Kristina Laboratory is an equal opportunity employer. #12;#12;LBNL-52235 Investigation of Residential Central Air;#12;Investigation of Residential Central Air Conditioning Load Shapes in NEMS i Table of Contents Acronyms

327

Performance Analysis of Photovoltaic Cell with Dynamic PHEV Loads  

E-Print Network (OSTI)

Performance Analysis of Photovoltaic Cell with Dynamic PHEV Loads F. R. Islam, H. R. Pota, M. S. Rahman and M. S. Ali Abstract--This paper presents the dynamics of photovoltaic (PV) cell with Plug for charging PHEVs with PV cell where PHEVs load are modelled based on third order battery model. System

Pota, Himanshu Roy

328

Loading guide for oil-immersed power transformers  

E-Print Network (OSTI)

Provides recommendations for the specification and loading of power transformers complying with IEC 60076, from the point of view of operating temperatures and thermal ageing. Gives recommendations for loading above the name-plate rating and guidance for the planner to choose rated quantities for new installations.

International Electrotechnical Commission. Geneva

1991-01-01T23:59:59.000Z

329

Modeling simple trigeneration systems for the distribution of environmental loads  

Science Conference Proceedings (OSTI)

Integration of thermoeconomics and Life Cycle Analysis was carried out within the framework of an Environmental Management Information System. This combined approach identified where environmental loads were generated and tracked environmental loads ... Keywords: CO2, Environmental Management Information System, Environmental costs, Material flow networks, Trigeneration, Umberto software

Monica Carvalho; Miguel A. Lozano; Luis M. Serra; Volker Wohlgemuth

2012-04-01T23:59:59.000Z

330

Finite element analysis of laterally loaded fin piles  

Science Conference Proceedings (OSTI)

A three-dimensional analysis of laterally loaded fin piles is presented. The behaviour of fin piles is difficult to explain using simple pile-soil theories or two dimensional numerical analyses because of the complicated geometry of the piles. In this ... Keywords: 3D finite element models, Capacity of laterally loaded piles, Efficiency of fins, Fin piles, Mohr-Coulomb soil model, Monopiles

J. -R. Peng; M. Rouainia; B. G. Clarke

2010-11-01T23:59:59.000Z

331

Enhancements to ANNSTLF, EPRI's Short Term Load Forecaster  

Science Conference Proceedings (OSTI)

Reliable hourly load forecasts are important to electric utilities, power marketers, energy service providers, and independent system operators. To meet this need, EPRI's Artificial Neural Net Short Term Load Forecaster (ANNSTLF), which is already implemented at more than thirty-five utilities, was recently enhanced for greater accuracy and user friendliness.

1997-12-08T23:59:59.000Z

332

Structural evaluation of the 2736Z Building for seismic loads  

SciTech Connect

The 2736Z building structure is evaluated for high-hazard loads. The 2736Z building is analyzed herein for normal and seismic loads and is found to successfully meet the guidelines of UCRL-15910 along with the related codes requirements.

Giller, R.A.

1994-09-23T23:59:59.000Z

333

Maria Research Reactor loaded with LEU - Otwock, Poland | National Nuclear  

National Nuclear Security Administration (NNSA)

Maria Research Reactor loaded with LEU - Otwock, Poland | National Nuclear Maria Research Reactor loaded with LEU - Otwock, Poland | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > Media Room > Video Gallery > Maria Research Reactor loaded with LEU - ... Maria Research Reactor loaded with LEU - Otwock, Poland Maria Research Reactor loaded with LEU - Otwock, Poland

334

Investigation of wind induced load on guyline anchors  

SciTech Connect

Most producing oil wells in the United States include guyline anchors to provide structural support for wind loaded service derricks. Recent safety regulations have focused attention on the load transferred to these anchors during high wind, but no definitive data has been available to establish precise requirements for such loading. In order to provide accurate and broadly acceptable data, a full scale field study was conducted on an actual servicing unit subject to severe wind. Load measured on the guyline anchors during the test indicates that there is less load on the guylines than standard criteria would predict. This result seems to be a singular property of oil well servicing units and is probably associated with both the flowfield around the derrick and the vertical velocity profile of the wind.

Hoyt, P.M.

1976-01-01T23:59:59.000Z

335

WIPP Mobile Loading Unit Contract - 8-27-12  

NLE Websites -- All DOE Office Websites (Extended Search)

DOE Awards Contract for WIPP Mobile Loading Unit Services DOE Awards Contract for WIPP Mobile Loading Unit Services Cincinnati, Ohio, August 27, 2012 - The U.S. Department of Energy (DOE) today awarded a competitive small business contract to Celeritex, LLC, (a Joint Venture between Project Services Group, LLC and DeNuke Contracting Services Inc.) of Suwanee, Georgia. The contract is to provide Mobile Loading Unit services in support of the National TRU Program and the DOE Carlsbad Field Office (CBFO) at the Waste Isolation Pilot Plant (WIPP) in New Mexico. The contract has a value of up to $17.8 million, with a three-year performance period and two- one year extension options. This contract was limited to Small Businesses. The Mobile Loading Unit contractor will load Contact Handled (CH) and Remote Handled (RH)

336

Definition: Interruptible Load Or Interruptible Demand | Open Energy  

Open Energy Info (EERE)

Interruptible Load Or Interruptible Demand Interruptible Load Or Interruptible Demand Jump to: navigation, search Dictionary.png Interruptible Load Or Interruptible Demand Demand that the end-use customer makes available to its Load-Serving Entity via contract or agreement for curtailment.[1] View on Wikipedia Wikipedia Definition View on Reegle Reegle Definition No reegle definition available. Also Known As non-firm service Related Terms transmission lines, electricity generation, transmission line, firm transmission service, smart grid References ↑ Glossary of Terms Used in Reliability Standards An inli LikeLike UnlikeLike You like this.Sign Up to see what your friends like. ne Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Interruptible_Load_Or_Interruptible_Demand&oldid=502615"

337

Building Energy Software Tools Directory: TRACE Load 700  

NLE Websites -- All DOE Office Websites (Extended Search)

Load 700 Load 700 TRACE Load 700 logo. Use TRACE Load 700 software - the building and load design modules of TRACE 700, Trane Air Conditioning Economics - to evaluate the effect of building orientation, size, shape, and mass based on hourly weather data and the resulting heat-transfer characteristics of air and moisture. To assure calculation integrity, the program uses algorithms recommended by the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). Choose from eight different ASHRAE cooling and heating methodologies, including the Exact Transfer Function. The program encourages "what if" analyses, allowing the user to enter construction details in any order and then easily change the resulting building model as the design progresses. Multiple project views and "drag-and-drop"

338

Loads Providing Ancillary Services: Review of International Experience |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Loads Providing Ancillary Services: Review of International Loads Providing Ancillary Services: Review of International Experience Loads Providing Ancillary Services: Review of International Experience In this study, we examine the arrangements for and experiences of end-use loads providing ancillary services (AS) in five electricity markets: Australia, the United Kingdom (UK), the Nordic market, and the ERCOT and PJM markets in the United States. Our objective in undertaking this review of international experience was to identify specific approaches or market designs that have enabled customer loads to effectively deliver various ancillary services (AS) products. We hope that this report will contribute to the ongoing discussion in the U.S. and elsewhere regarding what institutional and technical developments are needed to ensure that

339

Loads Providing Ancillary Services: Review of International Experience |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Loads Providing Ancillary Services: Review of International Loads Providing Ancillary Services: Review of International Experience Loads Providing Ancillary Services: Review of International Experience In this study, we examine the arrangements for and experiences of end-use loads providing ancillary services (AS) in five electricity markets: Australia, the United Kingdom (UK), the Nordic market, and the ERCOT and PJM markets in the United States. Our objective in undertaking this review of international experience was to identify specific approaches or market designs that have enabled customer loads to effectively deliver various ancillary services (AS) products. We hope that this report will contribute to the ongoing discussion in the U.S. and elsewhere regarding what institutional and technical developments are needed to ensure that

340

Load Component Database of Household Appliances and Small Office Equipment  

Science Conference Proceedings (OSTI)

This paper discusses the development of a load component database for household appliances and office equipment. To develop more accurate load models at both transmission and distribution level, a better understanding on the individual behaviors of home appliances and office equipment under power system voltage and frequency variations becomes more and more critical. Bonneville Power Administration (BPA) has begun a series of voltage and frequency tests against home appliances and office equipments since 2005. Since 2006, Researchers at Pacific Northwest National Laboratory has collaborated with BPA personnel and developed a load component database based on these appliance testing results to facilitate the load model validation work for the Western Electricity Coordinating Council (WECC). In this paper, the testing procedure and testing results are first presented. The load model parameters are then derived and grouped. Recommendations are given for aggregating the individual appliance models to feeder level, the models of which are used for distribution and transmission level studies.

Lu, Ning; Xie, YuLong; Huang, Zhenyu; Puyleart, Francis; Yang, Steve

2008-07-24T23:59:59.000Z

Note: This page contains sample records for the topic "loading front loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Grid Friendly Appliances – Load-side Solution for Congestion Management  

SciTech Connect

This paper discusses the effectiveness of deploying grid-friendly{trademark} appliances (GFAs) as a load-side solution for congestion management in a competitive electricity market, with the residential house ventilation and air conditioning (HVAC) load used as an example. A GFA is an appliance that can have a sensor and a controller installed to detect price, voltage, or frequency signals and turn on/off according to certain control logic. By using the congestion price as a signal to shift GFA power consumption from high-price periods to low-price periods to reduce load in load pocket areas, transmission line congestion can be successfully mitigated. The magnitude of GFA load reduction and the location of the GFA resources are critical to relieve congestion on targeted lines while not causing other lines to congest. Simulation results are presented and the impact of implementing price-responsive GFAs on the power grid is also studied.

Lu, Ning; Nguyen, Tony B.

2006-05-21T23:59:59.000Z

342

Hydrodynamic design loads for the OTEC cold water pipe  

DOE Green Energy (OSTI)

Ocean current and/or plant motion crossflows induce time dependent hydrodynamic loads on the OTEC cold water pipe due to vortex shedding. Design criteria were established for mean and fluctuating loads based on a review of the literature, analysis of test data acquired by SAI under a previous experimental program and an analytical extension of test results to higher Reynolds number. Baseline loads were specified for rigid cylinders in uniform flows. Modifications to the loads by current shear, stratification and cylinder motion, were investigated and final design criteria established. Limited structural response calculations were performed to demonstrate the use of the design criteria and to investigate briefly the possible structural response mode. Comparisons were made with alternate hydrodynamic loads, and recommendations were made for experimental verification.

Hove, D.; Shih, W.; Albano, E.

1978-09-01T23:59:59.000Z

343

Monitoring of Electrical End-Use Loads in Commercial Buildings  

E-Print Network (OSTI)

Southern California Edison is currently conducting a program to collect end-use metered data from commercial buildings in its service area. The data will provide actual measurements of end-use loads and will be used in research and in designing energy management programs oriented toward end-use applications. The focus of the program is on five major types of commercial buildings: offices, grocery stores, restaurants, retail stores, and warehouses. End-use metering equipment is installed at about 50 buildings, distributed among these five types. The buildings selected have average demands of 100 to 300 kW. The metered end-uses vary among building types and include HVAC, lighting, refrigeration. plug loads, and cooking. Procedures have been custom-designed to facilitate collection and validation of the end-use load data. For example, the Load Profile Viewer is a PC-based software program for reviewing and validating the end-use load data.

Martinez, M.; Alereza, T.; Mort, D.

1988-01-01T23:59:59.000Z

344

Static Heat Loads in the LHC Arc Cryostats: Final Assessment  

E-Print Network (OSTI)

This note presents the final assessment of the static heat loads in the LHC arc cryostats, using different experimental methods during the first commissioning period in 2007. This assessment further develops and completes previous estimates made during the commissioning of sector 7_8 [1]. The estimate of the helium inventory, a prerequisite for the heat load calculation, is also presented. Heat loads to the cold mass are evaluated from the internal energy balance during natural as well as powered warm-ups of the helium baths in different subsector. The helium inventory is calculated from the internal energy balance during powered warm-ups and matched with previous assessments. Furthermore, heat loads to the thermal shield are estimated from the non-isothermal cooling of the supercritical helium in line E. The comparison of measured heat loads with previous estimates and with budgeted values is then presented, while their correlation with some important parameters like insulation vacuum pressure and some heat ...

Parma, V

2010-01-01T23:59:59.000Z

345

Modeling and analysis of unsymmetrical transformer banks serving unbalanced loads  

SciTech Connect

It is a common practice to serve combination three-phase and single-phase loads from an unsymmetrical three-phase transformer bank and a four-wire secondary. Depending upon the loads and company standards, nine different transformer connections can be considered along with either an open four wire or a quadraplex secondary. The selection of the proper connection and transformer ratings can be achieved by the correct modeling and analysis of a system consisting of an equivalent source, transformer bank, secondary, and loads. This paper develops the models for the nine transformer connections, the secondary, and the loads. A computer program has been written that allows the analysis of the system for loading and short-circuit studies. The paper includes several examples of different normal and abnormal operating conditions on some of the transformer connections.

Kersting, W.H. [New Mexico State Univ., Las Cruces, NM (United States). Coll. of Engineering; Phillips, W.H. [WH Power Consultants, Las Cruces, NM (United States)

1996-05-01T23:59:59.000Z

346

Load as a reliability resource in restructured electricity markets  

Science Conference Proceedings (OSTI)

Recent electricity price spikes demonstrate the value that demand-side responses could bring to a restructured US electricity system. This report considers how even a modest increase in demand elasticity could dramatically reduce these extremes in price volatility. The report provides a three-part assessment addressing the ability of customer's load to participate in competitive markets and the current and potential future role of customer loads as system reliability resources. The study begins by evaluating the extent to which customer loads might be able to provide electricity reliability or ancillary services and reviewing aspects of a large utility's direct load control program. The second phase of the assessment contains a survey of ways in which load has been used as a system reliability resource focusing on programs triggered by system conditions and a real-time price signal. It reviews the experience of: (1) the California ISO's Demand Relief and Participating Load programs; (2) Interruptible load programs in California; (3) the New England ISO's Load Management program; and (4) a ''mature'' program in New Zealand. The third phase of the assessment examines the status of the underlying metering, communication, and control technologies used to effect customer responses. The final section of the report provides a vision of how the future might look and uses it to outline a program of needed R&D to increase the role of customer loads as system reliability resources. Key elements of this research program include: addressing the needs of system operators, making effective use of load management assets, making use of new program design concepts, the design of end-use technologies, and benefiting from program experiences.

Kueck, J.D.; Kirby, B.J.; Eto, J.; Staunton, R.H.; Marnay, C.; Martinez, A.; Goldman, C.

2001-06-01T23:59:59.000Z

347

Success stories will crack utility resistance to load management  

SciTech Connect

Advocates of load management see it as a solution to high fuel prices, better system load factors, and high utility earnings. Opposing views are investigated. It is conceded that both views have merit, but with proper attention to rate design, load management holds out hope for utility and customer alike. Westinghouse studies conclude that load management must be developed on a utility-specific basis. Many utilities are concerned that load management systems will reduce energy consumption and thus revenues. Experiences that utilities have had with radio and ripple control are briefly reviewed. Dr. Irwin Stelzer from the National Economic Research Associates says that, giving the customer the right price signal, the load curve will manipulate itself into the shape the customer wants. He advocates charging each customer precisely what it costs to deliver that customer's energy. It is seen that load management could improve the utility's income, possibly help defer the need for capital additions, and potentially help keep energy costs down. (MCW)

Owens, K.

1977-03-01T23:59:59.000Z

348

Multi-State Load Models for Distribution System Analysis  

Science Conference Proceedings (OSTI)

Recent work in the field of distribution system analysis has shown that the traditional method of peak load analysis is not adequate for the analysis of emerging distribution system technologies. Voltage optimization, demand response, electric vehicle charging, and energy storage are examples of technologies with characteristics having daily, seasonal, and/or annual variations. In addition to the seasonal variations, emerging technologies such as demand response and plug in electric vehicle charging have the potential to send control signals to the end use loads which will affect how they consume energy. In order to support time-series analysis over different time frames and to incorporate potential control signal inputs it is necessary to develop detailed end use load models which accurately represent the load under various conditions, and not just during the peak load period. This paper will build on previous work on detail end use load modeling in order to outline the method of general multi-state load models for distribution system analysis.

Schneider, Kevin P.; Fuller, Jason C.; Chassin, David P.

2011-11-01T23:59:59.000Z

349

Assessment of existing studies of wind loading on solar collectors  

DOE Green Energy (OSTI)

In developing solar collectors, wind loading is the major structural design consideration. Wind loading investigations have focused on establishing safe bounds for steady state loading and verifying rational but initial and conservative design approaches for the various solar collector concepts. As such, the effort has been very successful, and has contributed greatly to both the recognition and qualitative understanding of many of the physical phenomena involved. Loading coefficients corresponding to mean wind velocities have been derived in these prior studies to measure the expected structural loading on the various solar collectors. Current design and testing procedures for wind loading are discussed. The test results corresponding to numerous wind tests on heliostats, parabolic troughs, parabolic dishes, and field mounted photovoltaic arrays are discussed and the applicability of the findings across the various technologies is assessed. One of the most significant consistencies in the data from all the technologies is the apparent benefit provided by fences and field shielding. Taken in toto, these data show that load reductions of three or possibly more seem feasible, though a more thorough understanding of the phenomena involved must be attained before this benefit can be realized. It is recommended that the required understanding be developed to take advantage of this benefit and that field tests be conducted to correlate with both analyses and tests.

Murphy, L. M.

1981-02-01T23:59:59.000Z

350

Offshore loading-system design is aimed at higher efficiency  

SciTech Connect

Mobil Shipping and Transporation Co. has completed the design of an offshore loading system aimed at overcoming the limitations of existing terminals. The loading/mooring/storage system (LMS) is a semisubmersible vessel with ship mooring and loading facilities atop a box-shaped crude storage structure, which is well below the water line away from the effect of waves and clear of loading tankers' bows. The storage volume equals or exceeds that of a VLCC. There are 15 dual-purpose cargo/ballast tanks in the lower section with a control tower over the center tank. The loading system is designed to load 800,000 bbl of crude in about 12 hr. Each tank contains a diagonally suspended synthetic rubber diaphragm that will isolate crude from water ballast. Computer simulations based on North Sea weather data indicate that the LMS will allow marine loading efficiencies of at least 95Vertical Bar3< with total storage of a week's production or more. Other advantages of the LMS include the ability to moor shuttle tankers up to 200,000 dwt; self-contained repair and maintenance capabilities; and mobility. Variations of anchoring and riser systems for the LMS are discussed.

1978-05-08T23:59:59.000Z

351

Seismic Loading for FAST: May 2011 - August 2011  

DOE Green Energy (OSTI)

As more wind farms are constructed in seismically active regions, earthquake loading increases in prominence for design and analysis of wind turbines. Early investigation of seismic load tended to simplify the rotor and nacelle as a lumped mass on top of the turbine tower. This simplification allowed the use of techniques developed for conventional civil structures, such as buildings, to be easily applied to wind turbines. However, interest is shifting to more detailed models that consider loads for turbine components other than the tower. These improved models offer three key capabilities in consideration of base shaking for turbines: 1) The inclusion of aerodynamics and turbine control; 2) The ability to consider component loads other than just tower loads; and 3) An improved representation of turbine response in higher modes by reducing modeling simplifications. Both experimental and numerical investigations have shown that, especially for large modern turbines, it is important to consider interaction between earthquake input, aerodynamics, and operational loads. These investigations further show that consideration of higher mode activity may be necessary in the analysis of the seismic response of turbines. Since the FAST code is already capable of considering these factors, modifications were developed that allow simulation of base shaking. This approach allows consideration of this additional load source within a framework, the FAST code that is already familiar to many researchers and practitioners.

Asareh, M. A.; Prowell, I.

2012-08-01T23:59:59.000Z

352

Low-cost load research for electric utilities  

Science Conference Proceedings (OSTI)

Golden Valley Electric Association (GVEA) developed two pragmatic approaches to meet most load-research objectives at a substantially lower cost than would be incurred with traditional techniques. GVEA serves three customer classes, with most of its load in the Fairbanks area. GVEA's new approaches simulate load curves for individual customer classes to the degree necessary to meet most load-research objectives for the utility, including applications to cost-of-service analysis, rate design, demand-side management, and load forecasting. These approaches make class load-shape information available to utilities that cannot otherwise afford to develop such data. Although the two approaches were developed for a small utility, they are likely to work at least as well for medium and large utilities. The first approach simulates class curves by combining load data from system feeders with information on customer mix and energy usage. GVEA's supervisory control and data acquisition system gives hourly data on feeder loads, and its billing database provides the number of customers and kilowatt-hour usage by customer class on each feeder. The second approach enhances load-research results by redefining target parameters. Data from several like-hours are used to calculate substitutes for the parameters traditionally defined from single-hour data points. The precision of peak responsibility estimates, for example, can be improved if several of the highest hourly demands in a given time period are used rather than the single highest hourly demand. Arguably, use of several highest hourly demands can also improve the reliability of the allocation of responsibility.

Gray, D.A.; Butcher, M.

1994-08-01T23:59:59.000Z

353

End-Use Load-Shape Estimation: Methods and Validation  

Science Conference Proceedings (OSTI)

In developing effective demand-side management plans and load forecasts, utilities need information on customer hourly load patterns over a range of end-uses. Such information may be obtained using the two methods described in this report for disaggregating whole-building load data. Both methods have been validated using end-use metered data. This report is available only to funders of Program 101A or 101.001. Funders may download this report at http://my.primen.com/Applications/DE/Community/index.asp .

1991-02-01T23:59:59.000Z

354

Water Energy Load Profiling (WELP) Tool | Open Energy Information  

Open Energy Info (EERE)

Water Energy Load Profiling (WELP) Tool Water Energy Load Profiling (WELP) Tool Jump to: navigation, search Tool Summary Name: Water Energy Load Profiling (WELP) Tool Agency/Company /Organization: California Public Utilities Commission (CPUC) Sector: Energy, Water Focus Area: Energy Efficiency, - Embodied Energy, Water Conservation Phase: Determine Baseline, "Evaluate Effectiveness and Revise" is not in the list of possible values (Bring the Right People Together, Create a Vision, Determine Baseline, Evaluate Options, Develop Goals, Prepare a Plan, Get Feedback, Develop Finance and Implement Projects, Create Early Successes, Evaluate Effectiveness and Revise as Needed) for this property. Topics: GHG inventory, Policies/deployment programs, Resource assessment, Background analysis

355

Direct methanol fuel cells at reduced catalyst loadings  

DOE Green Energy (OSTI)

We focus in this paper on the reduction of catalyst loading in direct methanol fuel cells currently under development at Los Alamos National Laboratory. Based on single-cell DMFC testing, we discuss performance vs. catalyst loading trade-offs and demonstrate optimization of the anode performance. We also show test data for a short five-cell DMFC stack with the average total platinum loading of 0.53 mg cm{sup -2} and compare performance of this stack with the performance of a single direct methanol fuel cell using similar total amount of precious metal.

Zelenay, P. (Piotr); Guyon, F. (Francois); Gottesfeld, Shimshon

2001-01-01T23:59:59.000Z

356

Three Phase Probabilistic Load Flow in Radial Distribution Networks  

SciTech Connect

Probabilistic load flow is a helpful tool in accounting for inconsistent or unknown loads and generation. This is especially true with the push for renewable generation and demand response. This paper proposes an improved version of the probabilistic load flow solution for balanced distribution systems and takes the next step by applying it to unbalanced three phase systems. It is validated by comparing the solutions to that obtained by Monte Carlo simulation. The proposed method provides an accurate and practical way for finding the solution to the stochastic problems occurring in power distribution system analysis today.

Melhorn, Alexander C [ORNL; Dimitrovski, Aleksandar D [ORNL; Tomsovic, Kevin L [ORNL

2012-01-01T23:59:59.000Z

357

Loads Providing Ancillary Services: Review of International Experience  

SciTech Connect

In this study, we examine the arrangements for and experiences of end-use loads providing ancillary services (AS) in five electricity markets: Australia, the United Kingdom (UK), the Nordic market, and the ERCOT and PJM markets in the United States. Our objective in undertaking this review of international experience was to identify specific approaches or market designs that have enabled customer loads to effectively deliver various ancillary services (AS) products. We hope that this report will contribute to the ongoing discussion in the U.S. and elsewhere regarding what institutional and technical developments are needed to ensure that customer loads can meaningfully participate in all wholesale electricity markets.

Heffner, Grayson; Goldman, Charles; Kintner-Meyer, Michael

2007-05-01T23:59:59.000Z

358

DIRECT METHANOL FUEL CELLS AT REDUCED CATALYST LOADINGS  

DOE Green Energy (OSTI)

We focus in this paper on the reduction of catalyst loading in direct methanol fuel cells currently under development at Los Alamos National Laboratory. Based on single-cell DMFC testing, we discuss performance vs. catalyst loading trade-offs and demonstrate optimization of the anode performance. We also show test data for a short five-cell DMFC stack with the average total platinum loading of 0.53 mg cm{sup {minus}2} and compare performance of this stack with the performance of a single direct methanol fuel cell using similar total amount of precious metal.

P. ZELENAY; F. GUYON; SM. GOTTESFELD

2001-05-01T23:59:59.000Z

359

Aerosol penetration through a seismically loaded shear wall  

SciTech Connect

An experimental study was performed to measure the aerosol penetration through a reinforced concrete shear wall after simulated seismic damage. Static load-cycle testing, to stress levels sufficient to induce visible shear cracking, was used to simulate the earthquake loading. Air permeability tests were performed both before and after the simulated seismic loading damaged the structure. Aerosol penetration measurements were conducted on the cracked shear wall structure using 0.10 {mu}m monodisperse particles. The measured aerosol number penetration through the cracked shear wall was 0.5%. 7 refs.

Farrar, C.R.; Girrens, S.P.

1992-01-01T23:59:59.000Z

360

Aerosol penetration through a seismically loaded shear wall  

SciTech Connect

An experimental study was performed to measure the aerosol penetration through a reinforced concrete shear wall after simulated seismic damage. Static load-cycle testing, to stress levels sufficient to induce visible shear cracking, was used to simulate the earthquake loading. Air permeability tests were performed both before and after the simulated seismic loading damaged the structure. Aerosol penetration measurements were conducted on the cracked shear wall structure using 0.10 {mu}m monodisperse particles. The measured aerosol number penetration through the cracked shear wall was 0.5%. 7 refs.

Farrar, C.R.; Girrens, S.P.

1992-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "loading front loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Modeling, loading, and preliminary design considerations for tall guyed towers  

Science Conference Proceedings (OSTI)

In this paper, the authors first summarize the results of an investigation they carried out on the collapse of a 1900 ft tall guyed tower under ice and wind loads. Based on this investigation, they then proceed to present some structural analysis recommendations relating to loading and modeling concerns. Special emphasis is placed on the importance of ice loading, and on the level of accuracy required in modeling the nonlinear response behavior. Finally, the conclusions drawn from this study are used to formulate preliminary design guidelines. This facilitates a systematic approach for the design of tall guyed towers. 23 refs.

Gantes, C.; Khoury, R.; Connors, J.J.; Pouangare, C. [Engg Information Technology, Cambridge, MA (United States)

1993-12-01T23:59:59.000Z

362

Climatic indicators for estimating residential heating and cooling loads  

Science Conference Proceedings (OSTI)

An extensive data base of residential energy use generated with the DOE-2.1A simulation code provides an opportunity for correlating building loads predicted by an hourly simulation model to commonly used climatic parameters such as heating and cooling degree-days, and to newer parameters such as insolation-days and latent enthalpy-days. The identification of reliable climatic parameters for estimating cooling loads and the incremental loads for individual building components, such as changing ceiling and wall R-values, infiltration rates or window areas is emphasized.

Huang, Y.J.; Ritschard, R.; Bull, J.; Chang, L.

1986-11-01T23:59:59.000Z

363

A.: Modeling and forecasting electricity loads: A comparison  

E-Print Network (OSTI)

In this paper we study two statistical approaches to load forecasting. Both of them model electricity load as a sum of two components – a deterministic (representing seasonalities) and a stochastic (representing noise). They differ in the choice of the seasonality reduction method. Model A utilizes differencing, while Model B uses a recently developed seasonal volatility technique. In both models the stochastic component is described by an ARMA time series. Models are tested on a time series of system-wide loads from the California power market and compared with the official forecast of the California System Operator (CAISO). 1.

Rafa? Weron

2004-01-01T23:59:59.000Z

364

Input and output mass flux correlations in an experimental braided stream. Implications on the dynamics of bed load transport  

E-Print Network (OSTI)

analyzed. q 2002 Elsevier Science B.V. All rights reserved. Keywords: Braided river; Bed load transport.elsevier.com/locate/jhydrol 0022-1694/03/$ - see front matter q 2002 Elsevier Science B.V. All rights reserved. PII: S0022. But as shown by Brownlie (1981a,b), although they are important to our understanding of the gross pattern

Métivier, François

365

Warding Off Energy Vampires and Phantom Loads | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Warding Off Energy Vampires and Phantom Loads Warding Off Energy Vampires and Phantom Loads Warding Off Energy Vampires and Phantom Loads October 31, 2013 - 1:45pm Addthis This Halloween, keep energy vampires at bay -- while saving energy and money -- with these home energy efficiency tricks. | Infographic by Sarah Gerrity, Energy Department This Halloween, keep energy vampires at bay -- while saving energy and money -- with these home energy efficiency tricks. | Infographic by Sarah Gerrity, Energy Department Amy Royden-Bloom State Energy Program Supervisor Amy Kidd Project Officer, State Energy Program Ghosts and goblins may only come out on Halloween, but energy vampires and phantom loads lurk in our homes and offices all year long. Energy vampires are appliances or other plugged-in devices that draw energy, or

366

Incomplete Mixing, Intermittency and Fluctuating Toxic Load Measurements in  

NLE Websites -- All DOE Office Websites (Extended Search)

Incomplete Mixing, Intermittency and Fluctuating Toxic Load Measurements in Incomplete Mixing, Intermittency and Fluctuating Toxic Load Measurements in Indoor Plumes Speaker(s): David J. Wilson Date: October 19, 2007 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Richard Sextro Why have people been able to get away with ignoring intermittency (periods of zero concentration or zero turbulent temperature difference) in heat and mass transfer for the past century? Why is intermittency crucially important in toxic load estimates for biological exposure? We will explore how a simple back-of-the-envelope model can be constructed for the respiration toxicology of concentration fluctuations at a fixed receptor (for example; your lungs). This simple model will show the origin of the toxic load exponent n=2.0 for concentration C in L=Cnt. An extensive set of

367

Used Nuclear Fuel Loading and Structural Performance Under Normal  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Used Nuclear Fuel Loading and Structural Performance Under Normal Used Nuclear Fuel Loading and Structural Performance Under Normal Conditions of Transport - Modeling, Simulation and Experimental Integration RD&D Plan Used Nuclear Fuel Loading and Structural Performance Under Normal Conditions of Transport - Modeling, Simulation and Experimental Integration RD&D Plan Used nuclear fuel (UNF) must maintain its integrity during the storage period in such a way that it can withstand the physical forces of handling and transportation associated with restaging the fuel and transporting it to treatment or recycling facilities, or to a geologic repository. This RD&D plan describes a methodology, including development and use of analytical models, to evaluate loading and associated mechanical responses of UNF rods and key structural components. The plan objective is to

368

Assessing and Reducing Miscellaneous Electric Loads (MELs) in Banks  

Science Conference Proceedings (OSTI)

Miscellaneous electric loads (MELs) are loads outside of a building's core functions of heating, ventilating, air conditioning, lighting, and water heating. MELs are a large percentage of total building energy loads. This report reviews methods for reducing MELs in Banks. Reducing MELs in a bank setting requires both local and corporate action. Corporate action centers on activities to prioritize and allocate the right resources to correct procurement and central control issues. Local action includes branch assessment or audits to identify specific loads and needs. The worksheet at the end of this guide can help with cataloging needed information and estimating savings potential. The following steps provide a guide to MEL reductions in Bank Branches. The general process has been adapted from a process developed for office buildings the National Renewable Energy Laboratory (NREL, 2011).

Rauch, Emily M.

2012-09-01T23:59:59.000Z

369

NREL EFM DATA: Disaggregated Residential Load Cost Data The  

Open Energy Info (EERE)

EFM DATA: Disaggregated Residential Load Cost Data The following data-set is for a benchmark residential home for all TMY3 locations across all utilities in the US. The...

370

LMFBR subassembly response to local pressure loadings: an experimental approach  

SciTech Connect

An experimental program to determine the response of LMFBR-type subassemblies to local subassembly accidents caused by pressure loadings is described. Some results are presented and compared with computer calculations. (JWR)

Marciniak, T.J.; Ash, J.E.; Marchertas, A.H.; Cagliostro, D.J.

1975-01-01T23:59:59.000Z

371

Probability based load combinations for design of category I structures  

SciTech Connect

This paper discusses a reliability analysis method and a procedure for developing the load combination design criteria for category I structures. For safety evaluation of category I concrete structures under various static and dynamic loads, a probability-based reliability analysis method has been developed. This reliability analysis method is also used as a tool for determining the load factors for design of category I structures. In this paper, the load combinations for design of concrete containments, corresponding to a target limit state probability of 1.0 x 10/sup -6/ in 4 years, are described. A comparison of containments designed using the ASME code and the proposed design criteria is also presented.

Reich, M.; Hwang, H.

1985-01-01T23:59:59.000Z

372

Load flow analysis: Base cases, data, diagrams, and results  

SciTech Connect

This report describes how an electric utility system is modeled by using load flow techniques to establish a validated power flow case suitable for simulating and evaluating alternative system scenarios. Details of the load flow model are supported by additional technical and descriptive information intended to correlate modeled electrical system parameters with the corresponding physical equipment that makes up the system. Pictures and technical specifications of system equipment from the utility, public, or vendor are provided to support this association for many system components. The report summarizes the load flow model construction, simulation, and validation and describes the general capabilities of an information query system designed to access load flow parameters and other electrical system information.

Portante, E.C.; Kavicky, J.A.; VanKuiken, J.C.; Peerenboom, J.P.

1997-10-01T23:59:59.000Z

373

Building Energy Software Tools Directory: Prophet Load Profiler  

NLE Websites -- All DOE Office Websites (Extended Search)

Prophet Load Profiler Prophet Load Profiler Prophet Load Profiler logo. Internet-enabled software that empowers business energy customers to manage energy and reduce costs. Valuable to facility managers, energy managers and energy service companies, the Prophet web-based service delivers real-time and near-real-time energy information on energy consumption and demand for any size facility. A number of facilities can be managed using consumption data gathered in 15 minute, 30 minute, 60 minute, daily, weekly and monthly intervals. Users can immediately view and analyze data with an eye toward load shedding, cost avoidance strategies, energy budget management, utility cost validation and energy forecasting. All tools are contained within the Prophet Web application and enabled via the internet using a standard web

374

Decentralized customerlevel under frequency load shedding in Switzerland  

Open Energy Info (EERE)

customerlevel under frequency load shedding in Switzerland customerlevel under frequency load shedding in Switzerland (Smart Grid Project) Jump to: navigation, search Project Name Decentralized customerlevel under frequency load shedding in Switzerland Country Switzerland Coordinates 46.818188°, 8.227512° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":46.818188,"lon":8.227512,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

375

Warding Off Energy Vampires and Phantom Loads | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Warding Off Energy Vampires and Phantom Loads Warding Off Energy Vampires and Phantom Loads Warding Off Energy Vampires and Phantom Loads October 31, 2013 - 1:45pm Addthis This Halloween, keep energy vampires at bay -- while saving energy and money -- with these home energy efficiency tricks. | Infographic by Sarah Gerrity, Energy Department This Halloween, keep energy vampires at bay -- while saving energy and money -- with these home energy efficiency tricks. | Infographic by Sarah Gerrity, Energy Department Amy Royden-Bloom State Energy Program Supervisor Amy Kidd Project Officer, State Energy Program Ghosts and goblins may only come out on Halloween, but energy vampires and phantom loads lurk in our homes and offices all year long. Energy vampires are appliances or other plugged-in devices that draw energy, or

376

Electric Load vs Time: Complicated World, Complicated Model  

NLE Websites -- All DOE Office Websites (Extended Search)

Electric Load vs Time: Complicated World, Complicated Model Electric Load vs Time: Complicated World, Complicated Model Speaker(s): Phillip Price Date: March 7, 2013 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Phillip Price "How much energy did I save by changing the operation of my building yesterday?" That turns out to be a very hard question to answer: you need to know how much energy you would have used under normal operations (the "baseline"), a number you can predict but not measure. In this talk we focus specifically on electrical energy ("electric load") in commercial buildings. Often the load can be broken down into several components that are superimposed on each other: a recurring weekly pattern, an effect of outdoor air temperature, and so on. Some buildings have patterns that are

377

AEDG Implementation Recommendations: Cooling and Heating Loads | Building  

NLE Websites -- All DOE Office Websites (Extended Search)

Cooling and Heating Loads Cooling and Heating Loads The Advanced Energy Design Guide (AEDG) for Small Office Buildings, 30% series, seeks to achieve 30% savings over ASHRAE Standard 90.1-1999. This guide focuses on improvements to small office buildings, less than 20,000ft2. The recommendations in this article are adapted from the implementation section of the guide and focus on heating and cooling system design loads for the purpose of sizing systems and equipment should be calculated in accordance with generally accepted engineering standards and handbooks such as ASHRAE Handbook--Fundamentals. Publication Date: Wednesday, May 13, 2009 air_cooling_and_heating_loads.pdf Document Details Affiliation: DOE BECP Focus: Compliance Building Type: Commercial Code Referenced: ASHRAE Standard 90.1-1999

378

A detailed loads comparison of three building energy modeling programs:  

NLE Websites -- All DOE Office Websites (Extended Search)

detailed loads comparison of three building energy modeling programs: detailed loads comparison of three building energy modeling programs: EnergyPlus, DeST and DOE-2.1E Title A detailed loads comparison of three building energy modeling programs: EnergyPlus, DeST and DOE-2.1E Publication Type Journal Year of Publication 2013 Authors Zhu, Dandan, Tianzhen Hong, Da Yan, and Chuang Wang Date Published 05/2013 Keywords building energy modeling program, building thermal loads, comparison, dest, DOE-2.1E, energyplus Abstract Building energy simulation is widely used to help design energy efficient building envelopes and HVAC systems, develop and demonstrate compliance of building energy codes, and implement building energy rating programs. However, large discrepancies exist between simulation results from different building energy modeling programs (BEMPs). This leads many users and stakeholders

379

Non-Intrusive Load Monitoring - Recent Advances and Existing Challenges  

NLE Websites -- All DOE Office Websites (Extended Search)

Non-Intrusive Load Monitoring - Recent Advances and Existing Challenges Non-Intrusive Load Monitoring - Recent Advances and Existing Challenges Speaker(s): Hampden Kuhns Date: May 10, 2010 - 12:00pm Location: 90-3122 Non-Intrusive Load Monitoring (NILM) describes the process of disaggregating multiple energy loads on a single circuit using signal processing techniques. The granular output of this analysis (much like an itemized phone bill) can help rate payers identify inefficiencies in their buildings and promote cost-effective energy efficiency actions. The concepts behind NIALM were originally developed in the late 1980s by George Hart of MIT and commercialized by Enetics Inc, but hardware expense, accuracy, and detection limit issues have hampered its large scale adoption. This presentation discusses the several steps of the original

380

Used Nuclear Fuel Loading and Structural Performance Under Normal  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Nuclear Fuel Loading and Structural Performance Under Normal Nuclear Fuel Loading and Structural Performance Under Normal Conditions of Transport - Modeling, Simulation and Experimental Integration RD&D Plan Used Nuclear Fuel Loading and Structural Performance Under Normal Conditions of Transport - Modeling, Simulation and Experimental Integration RD&D Plan Used nuclear fuel (UNF) must maintain its integrity during the storage period in such a way that it can withstand the physical forces of handling and transportation associated with restaging the fuel and transporting it to treatment or recycling facilities, or to a geologic repository. This RD&D plan describes a methodology, including development and use of analytical models, to evaluate loading and associated mechanical responses of UNF rods and key structural components. The plan objective is to

Note: This page contains sample records for the topic "loading front loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

California Customer Load Reductions during the Electricity Crisis: Did They  

Open Energy Info (EERE)

California Customer Load Reductions during the Electricity Crisis: Did They California Customer Load Reductions during the Electricity Crisis: Did They Help to Keep the Lights On? Jump to: navigation, search Tool Summary LAUNCH TOOL Name: California Customer Load Reductions during the Electricity Crisis: Did They Help to Keep the Lights On? Focus Area: Energy Efficiency Topics: Socio-Economic Website: eetd.lbl.gov/ea/ems/reports/49733.pdf Equivalent URI: cleanenergysolutions.org/content/california-customer-load-reductions-d Language: English Policies: Regulations Regulations: Mandates/Targets This report details the predicted electricity shortages and blackouts in California (summer 2001) that never occured, in part due to energy conservation measures taken on by the people of California. Intense media coverage and information campaigns about energy efficiency as well as

382

Energy Efficiency Indicators for High Electric-Load Buildings  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy Efficiency Indicators for High Electric-Load Buildings Speaker(s): Bernard Aebischer Date: February 6, 2003 - 12:00pm Location: Bldg. 90 Seminar HostPoint of Contact:...

383

Review of Residential Low-Load HVAC Systems  

SciTech Connect

In support of the U.S. Department of Energy’s (DOE’s) Building America Program, Pacific Northwest National Laboratory (PNNL) conducted an investigation to inventory commercially available HVAC technologies that are being installed in low-load homes. The first step in this investigation was to conduct a review of published literature to identify low-load HVAC technologies available in the United States and abroad, and document the findings of existing case studies that have evaluated the performance of the identified technologies. This report presents the findings of the literature review, identifies gaps in the literature or technical understanding that must be addressed before low-load HVAC technologies can be fully evaluated, and introduces PNNL’s planned research and analysis for this project to address identified gaps and potential future work on residential low-load HVAC systems.

Brown, Scott A.; Thornton, Brian; Widder, Sarah H.

2013-09-01T23:59:59.000Z

384

Improving shipboard applications of non-intrusive load monitoring  

E-Print Network (OSTI)

The Non-Intrusive Load Monitor (NILM) measures equipment performance by measuring and analyzing the source power to the equipment at a single point in the electrical system. Previous studies have proven the usefulness of ...

Jones, Richard A. (Richard Alan), Nav. E. Massachusetts Institute of Technology

2008-01-01T23:59:59.000Z

385

T-load microchannel array and fabrication method  

DOE Patents (OSTI)

A three-dimensional (3-D) T-load for planar microchannel arrays for electrophoresis, for example, which enables sample injection directly onto a plane perpendicular to the microchannels' axis, at their ends. This is accomplished by forming input wells that extend beyond the ends of the microchannel thereby eliminating the right angle connection from the input well into the end of the microchannel. In addition, the T-load input well eases the placement of electrode in or adjacent the well and thus enables very efficient reproducible electrokinetic (ek) injection. The T-load input well eliminates the prior input well/microchannel alignment concerns, since the input well can be drilled after the top and bottom microchannel plates are bonded together. The T-load input well may extend partially or entirely through the bottom microchannel plate which enables more efficient gel and solution flushing, and also enables placement of multiple electrodes to assist in the ek sample injection.

Swierkowski, Stefan P. (Livermore, CA)

2000-01-01T23:59:59.000Z

386

Wakefield Breakdown Test of a Diamond-Loaded Accelerating Structure  

NLE Websites -- All DOE Office Websites (Extended Search)

WAKEFIELD BREAKDOWN TEST OF A DIAMOND-LOADED ACCELERATING STRUCTURE S. Antipov, C. Jing, A. Kanareykin, P. Schoessow Euclid TechLabs LLC, Solon, OH, 44139 USA M. Conde, W. Gai, S....

387

Wakefield Breakdown Test of a Diamond-loaded Accelerating Structure...  

NLE Websites -- All DOE Office Websites (Extended Search)

WAKEFIELD BREAKDOWN TEST OF A DIAMOND-LOADED ACCELERATING STRUCTURE AT THE AWA S. Antipov, C. Jing, P. Schoessow, J. E. Butler, S. Zuo and A. Kanareykin, Euclid Techlabs LLC,...

388

Energy Storage for Use in Load Frequency Control  

E-Print Network (OSTI)

Certain energy storage technologies are well-suited to the high-frequency, high-cycling operation which is required in provision of load frequency control (LFC). To limit the total stored energy capacity required while ...

Leitermann, Olivia

389

Industrial Load Shaping: A Utility Strategy to Deal with Competition  

E-Print Network (OSTI)

In recent years competition from various sources such as cogeneration and bypass has led many utilities to refocus attention on their large industrial customers. Industrial load shaping is a customized program involving cost-effective process modifications and operational changes which result in a restructuring of the electric load profile of individual manufacturing facilities. Both the customer and the utility should realize benefits from these changes. There are five generic load shaping categories: rescheduling operations, capacity additions, product storage, automation and flexible manufacturing and electrotechnologies. The customized nature of the program requires that the utility work with industry experts to help customers identify specific load shape opportunities. The remainder of this paper provides guidelines for utility planners interested in developing such a program. It begins with an overview of general objectives, technology alternatives, market evaluation and selection criteria, and program implementation and monitoring procedures. The paper concludes with two utility case studies.

Bules, D.

1987-09-01T23:59:59.000Z

390

Adaptive load control of microgrids with non-dispatchable generation  

E-Print Network (OSTI)

Intelligent appliances have a great potential to provide energy storage and load shedding for power grids. Microgrids are simulated with high levels of wind energy penetration. Frequency-adaptive intelligent appliances are ...

Brokish, Kevin Martin

2009-01-01T23:59:59.000Z

391

Effects of Microstructure and Loading Parameters on Fatigue Crack ...  

Science Conference Proceedings (OSTI)

stress values (R = 0.7 and 0.05) and two frequencies (10 and 2. Hz) at 649 “C. The ... R=O.O5 and the sinusoidal load frequency was 2 Hz. Some implications of

392

Temperature Effects on the Winter Daily Electric Load  

Science Conference Proceedings (OSTI)

Here we describe the relationship between average daily temperature and winter-daily electric load, as ascertained on the largest electric district in Italy. In particular, it is shown that a sudden 6°C temperature decrease (not a rare event) ...

Paolo Bolzern; Giorgio Fronza; Giuseppe Brusasca

1982-02-01T23:59:59.000Z

393

The Slope of Moist Symmetric Instability with Water Loading  

Science Conference Proceedings (OSTI)

Idealized numerical experiments, supported by analytic considerations, are performed to determine the preferred direction of symmetric instability when water loading is considered. It is concluded that the most unstable direction is tangent to a ...

Maurizio Fantini; Piero Malguzzi

2008-09-01T23:59:59.000Z

394

Generation of High Gradient Wakefields in Dielectric Loaded Structures  

NLE Websites -- All DOE Office Websites (Extended Search)

loaded wakefield structures to generate accelerating fields of up to 100 MVm. Short electron bunches (13 ps FWHM) of up to 86 nC are used to drive these fields, either as single...

395

A Climatological Measure of Extreme Snowdrift Loading on Building Roofs  

Science Conference Proceedings (OSTI)

A physical model of snow transport and deposition is used in combination with historical climatological data to derive a climatological measure of extreme snowdrift loads on building roofs. The snowdrift metric used relies on hourly wind speed, ...

Arthur T. DeGaetano; Michael J. O'Rourke

2004-01-01T23:59:59.000Z

396

Compensation of Beam Loading in the ALS Injector Linac  

E-Print Network (OSTI)

to offset the beam loading. ALS Injector Requirements Gun.gun, bunchers, and 50 MeV linac of the ALS injection system.The ALS injector design has been described in previous

Selph, F.

1988-01-01T23:59:59.000Z

397

Transient beam loading in the ALS harmonic RF system  

E-Print Network (OSTI)

TRANSIENT BEAM LOADING IN THE ALS HARMONIC RF SYSTEM * J.as the Advanced Light Source (ALS), with moderately low beamharmonic RF system on the ALS storage ring consisting of 5

2000-01-01T23:59:59.000Z

398

Characterizing Highly Varying Loads Associated With the Steel Industry  

Science Conference Proceedings (OSTI)

This study examines the quality of power and the effects of the highly varying load on automatic generation control at a utility service territory that contains 22% of the United States' steel manufacturing capability.

2003-12-31T23:59:59.000Z

399

Monitoring of electrical end-use loads in commercial buildings  

Science Conference Proceedings (OSTI)

A California utility is currently conducting a program to collect end-use metered data from commercial buildings in its service area. The data will provide actual measurements of end-use loads and will be used in research and in designing energy management programs oriented toward end-use applications. The focus of the program is on five major types of commercial buildings: offices, grocery stores, restaurants, retail stores, and warehouses. End-use metering equipment is installed at about 50 buildings selected have average demands of 100kW to 300 kW. The metered end-uses vary among building types and include HVAC, lighting, refrigeration, plug loads, and cooking. Procedures have been custom-designed to facilitate collection and validation of the end-use load data. PC-based software programs have been developed for reviewing and validating the end-sue load data and for generating reports.

Martinez, M. (Southern California Edison, CA (US)); Alereza, T.; Mort, D. (ADM Associates, Sacramento, CA (US))

1989-01-01T23:59:59.000Z

400

Application of Learning Fuzzy Inference Systems in Electricity Load Forecast  

E-Print Network (OSTI)

This paper highlights the results and applied techniques for the electricity load forecast competition organised by the European Network on Intelligent Technologies for Smart Adaptive Systems (www.eunite.org). The electricity load forecast problem is tackled in two di#erent stages by creating two di#erent models. The first model will predict the temperature and the second model uses the predicted temperature to forecast the maximum electricity load. For both model, learning fuzzy inference systems are applied. Initial fuzzy rules are generated and then the numerical data provided by Eastern Slovakian Electricity Corporation are used to learn the parameters of the learning fuzzy inference systems. The learning technique is applied for both temperature and load forecast.

Ahamd Lotfi

2001-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "loading front loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Energy efficiency indicators for high electric-load buildings  

Science Conference Proceedings (OSTI)

Energy per unit of floor area is not an adequate indicator for energy efficiency in high electric-load buildings. For two activities, restaurants and computer centres, alternative indicators for energy efficiency are discussed.

Aebischer, Bernard; Balmer, Markus A.; Kinney, Satkartar; Le Strat, Pascale; Shibata, Yoshiaki; Varone, Frederic

2003-06-01T23:59:59.000Z

402

Miscellaneous and Electronic Loads Energy Efficiency Opportunities for  

NLE Websites -- All DOE Office Websites (Extended Search)

Miscellaneous and Electronic Loads Energy Efficiency Opportunities for Miscellaneous and Electronic Loads Energy Efficiency Opportunities for Commercial Buildings: A Collaborative Study by the United States and India Title Miscellaneous and Electronic Loads Energy Efficiency Opportunities for Commercial Buildings: A Collaborative Study by the United States and India Publication Type Report Refereed Designation Unknown LBNL Report Number LBNL-6287E Year of Publication 2013 Authors Ghatikar, Girish, Iris H. Y. Cheung, and Steven Lanzisera Secondary Authors Wardell, Bob, Manoj Deshpande, Jayraj Ugarkar, and Infosys Technologies Limited Date Published 04/2013 Keywords Electronic loads, energy efficiency opportunities for commercial buildings Short Title MELs Refereed Designation Unknown Attachment Size PDF 1.44 MB Google Scholar BibTex

403

Estimating Demand Response Load Impacts: Evaluation of BaselineLoad Models for Non-Residential Buildings in California  

SciTech Connect

Both Federal and California state policymakers areincreasingly interested in developing more standardized and consistentapproaches to estimate and verify the load impacts of demand responseprograms and dynamic pricing tariffs. This study describes a statisticalanalysis of the performance of different models used to calculate thebaseline electric load for commercial buildings participating in ademand-response (DR) program, with emphasis onthe importance of weathereffects. During a DR event, a variety of adjustments may be made tobuilding operation, with the goal of reducing the building peak electricload. In order to determine the actual peak load reduction, an estimateof what the load would have been on the day of the event without any DRactions is needed. This baseline load profile (BLP) is key to accuratelyassessing the load impacts from event-based DR programs and may alsoimpact payment settlements for certain types of DR programs. We testedseven baseline models on a sample of 33 buildings located in California.These models can be loosely categorized into two groups: (1) averagingmethods, which use some linear combination of hourly load values fromprevious days to predict the load on the event, and (2) explicit weathermodels, which use a formula based on local hourly temperature to predictthe load. The models were tested both with and without morningadjustments, which use data from the day of the event to adjust theestimated BLP up or down.Key findings from this study are: - The accuracyof the BLP model currently used by California utilities to estimate loadreductions in several DR programs (i.e., hourly usage in highest 3 out of10 previous days) could be improved substantially if a morning adjustmentfactor were applied for weather-sensitive commercial and institutionalbuildings. - Applying a morning adjustment factor significantly reducesthe bias and improves the accuracy of all BLP models examined in oursample of buildings. - For buildings with low load variability, all BLPmodels perform reasonably well in accuracy. - For customer accounts withhighly variable loads, we found that no BLP model produced satisfactoryresults, although averaging methods perform best in accuracy (but notbias). These types of customers are difficult to characterize withstandard BLP models that rely on historic loads and weather data.Implications of these results for DR program administrators andpolicymakersare: - Most DR programs apply similar DR BLP methods tocommercial and industrial sector customers. The results of our study whencombined with other recent studies (Quantum 2004 and 2006, Buege et al.,2006) suggests that DR program administrators should have flexibility andmultiple options for suggesting the most appropriate BLP method forspecific types of customers.

Coughlin, Katie; Piette, Mary Ann; Goldman, Charles; Kiliccote,Sila

2008-01-01T23:59:59.000Z

404

Loading capacity of various filters for lithium fire generated aerosols  

Science Conference Proceedings (OSTI)

The lithium aerosol loading capacity of a prefilter, HEPA filters and a sand and gravel bed filter was determined. The test aerosol was characterized and was generated by burning lithium in an unlimited air atmosphere. Correlation to sodium aerosol loading capacities were made to relate existing data to lithium aerosol loadings under varying conditions. This work is being conducted in support of the fusion reactor safety program. The lithium aerosol was generated by burning lithium pools, up to 45 kgs, in a 340 m/sup 3/ low humidity air atmosphere to supply aerosol to recirculating filter test loops. The aerosol was sampled to determine particle size, mass concentrations and chemical species. The dew point and gas concentrations were monitored throughout the tests. Loop inlet aerosol mass concentrations ranged up to 5 gr/m/sup 3/. Chemical compounds analyzed to be present in the aerosol include Li/sub 2/O, LiOH, and Li/sub 2/CO/sub 3/. HEPA filters with and without separators and a prefilter and HEPA filter in series were loaded with 7.8 to 11.1 kg/m/sup 2/ of aerosol at a flow rate of 1.31 m/sec and 5 kPa pressure drop. The HEPA filter loading capacity was determined to be greater at a lower flow rate. The loading capacity increased from 0.4 to 2.8 kg by decreasing the flow rate from 1.31 to 0.26 m/sec for a pressure drop of 0.11 kPa due to aerosol buildup. The prefilter tested in series with a HEPA did not increase the total loading capacity significantly for the same total pressure drop. Separators in the HEPA had only minor effect on loading capacity. The sand and gravel bed filter loaded to 0.50 kg/m/sup 2/ at an aerosol flow rate of 0.069 m/sec and final pressure drop of 6.2 kPa. These loading capacities and their dependence on test variables are similar to those reported for sodium aerosols except for the lithium aerosol HEPA loading capacity dependence upon flow rate.

Jeppson, D.W.; Barreca, J.R.

1980-10-23T23:59:59.000Z

405

Investigation of residential central air conditioning load shapes in NEMS  

SciTech Connect

This memo explains what Berkeley Lab has learned about how the residential central air-conditioning (CAC) end use is represented in the National Energy Modeling System (NEMS). NEMS is an energy model maintained by the Energy Information Administration (EIA) that is routinely used in analysis of energy efficiency standards for residential appliances. As part of analyzing utility and environmental impacts related to the federal rulemaking for residential CAC, lower-than-expected peak utility results prompted Berkeley Lab to investigate the input load shapes that characterize the peaky CAC end use and the submodule that treats load demand response. Investigations enabled a through understanding of the methodology by which hourly load profiles are input to the model and how the model is structured to respond to peak demand. Notably, it was discovered that NEMS was using an October-peaking load shape to represent residential space cooling, which suppressed peak effects to levels lower than expected. An apparent scaling down of the annual load within the load-demand submodule was found, another significant suppressor of the peak impacts. EIA promptly responded to Berkeley Lab's discoveries by updating numerous load shapes for the AEO2002 version of NEMS; EIA is still studying the scaling issue. As a result of this work, it was concluded that Berkeley Lab's customary end-use decrement approach was the most defensible way for Berkeley Lab to perform the recent CAC utility impact analysis. This approach was applied in conjunction with the updated AEO2002 load shapes to perform last year's published rulemaking analysis. Berkeley Lab experimented with several alternative approaches, including modifying the CAC efficiency level, but determined that these did not sufficiently improve the robustness of the method or results to warrant their implementation. Work in this area will continue in preparation for upcoming rulemakings for the other peak coincident end uses, commercial air conditioning and distribution transformers.

Hamachi LaCommare, Kristina; Marnay, Chris; Gumerman, Etan; Chan, Peter; Rosenquist, Greg; Osborn, Julie

2002-05-01T23:59:59.000Z

406

End-Use Load Research in a Smart Grid World  

Science Conference Proceedings (OSTI)

In October 2010, EPRI conducted a workshop with EPRI members to identify how broad application of "Smart Grid" or advanced metering infrastructure (AMI) technologies could both increase need for and reduce cost of acquiring high-quality load research data. Representatives from regulated utilities, independent system operators/regional transmission organizations (ISO/RTOs), and industry experts participated. Utility representatives said that they are using "antique" load shape data for forecasting, planni...

2010-12-23T23:59:59.000Z

407

Selected Statistical Methods for Analysis of Load Research Data  

Science Conference Proceedings (OSTI)

Applying innovative statistical methods, researchers developed a probabilistic approach that treats loads as random variables. Though preliminary, these findings can lead to a better understanding of load research design and more efficient use of the data. This report is available only to funders of Program 101A or 101.001. Funders may download this report at http://my.primen.com/Applications/DE/Community/index.asp .

1984-05-01T23:59:59.000Z

408

Incremental cooling load determination for passive direct gain heating systems  

DOE Green Energy (OSTI)

This paper examines the applicability of the National Association of Home Builders (NAHB) full load compressor hour method for predicting the cooling load increase in a residence, attributable to direct gain passive heating systems. The NAHB method predictions are compared with the results of 200 hour-by-hour simulations using BLAST and the two methods show reasonable agreement. The degree of agreement and the limitations of the NAHB method are discussed.

Sullivan, P.W.; Mahone, D.; Fuller, W.; Gruber, J.; Kammerud, R.; Place, W.; Andersson, B.

1981-05-01T23:59:59.000Z

409

STLOAD 1.0, Substation Equipment Thermal Loading Program  

Science Conference Proceedings (OSTI)

The Substation Equipment Thermal Loading Program, STLOAD Version 1.0 software is intended for use by substation engineers for the purpose of establishing thermal ratings for and making diagnostic evaluations of substation equipment. STLOAD 1.0 software calculates substation equipment operating temperatures and thermal ratings based on user-specified physical parameters for the equipment and user-specified load and air temperature data. Substation equipment that can be modeled using STLOAD includes strain...

2006-03-15T23:59:59.000Z

410

PTLOAD: Comparison of Calculation Results Against Transformer Loading Standards  

Science Conference Proceedings (OSTI)

Power transformers are one of the most expensive components of any transmission system. Energy companies need to maximize utilization of these assets, while at the same time protecting them from damage and ensuring system reliability. To assist utilities in planning transformer loading, PTLOAD implements calculation methods from Institute of Electrical and Electronics Engineers (IEEE) C57.91-1995, "Guide for Loading Mineral-Oil-Immersed Transformers," as well as the International Electrotechnical Commiss...

2011-12-23T23:59:59.000Z

411

Market Driven Distributed Energy Storage Requirements for Load Management Applications  

Science Conference Proceedings (OSTI)

Electric energy storage systems are an enabling technology that could help meet the needs of electric utility by managing peak energy demands, helping shift the peak loads to off peak hours and improving the load factor of the electric distribution system. Applications of distributed energy storage systems (DESS) could also provide power quality and reliability benefits to customers and to the electric system. EPRI collaborated with several investor owned utilities to conduct a study to understand the te...

2007-04-18T23:59:59.000Z

412

Effect of DC Load Currents on Solid State Residential Meters  

Science Conference Proceedings (OSTI)

This report presents results of an extensive laboratory assessment of the impact of DC load currents (including half-wave rectified loads) on the metrological accuracy of residential solid state electricity meters. Sampled surveys were conducted to determine whether products producing DC currents are prevalent in residential premises. In addition, regulations and codes were studied to determine whether such products could naturally appear in the marketplace going forward. Two each of six brands of socket...

2011-12-22T23:59:59.000Z

413

Noninstrusive Appliance Load Monitoring System (NIALMS): Beta-Test Results  

Science Conference Proceedings (OSTI)

Traditional methods for gathering appliance-specific load data require installation of individual recording meters on each appliance or multi-channel recording meters with remote sensors on individual appliances. This is a highly intrusive approach that is expensive and cumbersome in terms of capital, labor, and customer goodwill. A newly developed non-intrusive appliance load monitoring system (NIALMS) promises to minimize many of the costs of traditional end-use metering approaches.

1997-11-04T23:59:59.000Z

414

A model of the domestic hot water load  

SciTech Connect

The electrical load required to supply domestic hot water is an important load for two reasons: (1) It represents a large portion (30 to 50%) of the domestic load; (2) It is a load which can easily be controlled by the consumer or the supplier, because the use of the hot water need not coincide with the heating of hot water. A model representing the electrical system load due to hot water consumption from storage water heaters is provided. Variable parameters include the average amount of water used, the mean and deviation of distributions of usage times, thermostat settings, inlet water temperature and electrical heating element ratings. These parameters are used to estimate the after diversity electricity demand profile, and were verified for accuracy by comparison with measurements. The model enables this prediction of the effects of load control, examples of which are given in this paper. The model is also useful for evaluation of the response which could be expected from demand-side management options. These include changing the size of heating elements, reduction in water consumption and reduction in thermostat settings.

Lane, I.E. [Energy Efficiency Enterprises, Lynnwood Manor (South Africa); Beute, N. [Cape Technikon, Cape Town (South Africa)

1996-11-01T23:59:59.000Z

415

Selecting a Control Strategy for Plug and Process Loads  

Science Conference Proceedings (OSTI)

Plug and Process Loads (PPLs) are building loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the building occupants. PPLs in commercial buildings account for almost 5% of U.S. primary energy consumption. On an individual building level, they account for approximately 25% of the total electrical load in a minimally code-compliant commercial building, and can exceed 50% in an ultra-high efficiency building such as the National Renewable Energy Laboratory's (NREL) Research Support Facility (RSF) (Lobato et al. 2010). Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. A complex array of technologies that measure and manage PPLs has emerged in the marketplace. Some fall short of manufacturer performance claims, however. NREL has been actively engaged in developing an evaluation and selection process for PPLs control, and is using this process to evaluate a range of technologies for active PPLs management that will cap RSF plug loads. Using a control strategy to match plug load use to users' required job functions is a huge untapped potential for energy savings.

Lobato, C.; Sheppy, M.; Brackney, L.; Pless, S.; Torcellini, P.

2012-09-01T23:59:59.000Z

416

Transportation Electrification Load Development For A Renewable Future Analysis: Preprint  

DOE Green Energy (OSTI)

The transition to electricity as a transportation fuel will create a new load for electricity generation. A set of regional hourly load profiles for electrified vehicles was developed for the 2010 to 2050 timeframe. The transportation electrical energy was determined using regional population forecast data, historical vehicle per capita data, and market penetration growth functions to determine the number of plug-in electric vehicles (PEVs) in each analysis region. Market saturation scenarios of 30% and 50% of sales of PEVs consuming on average approx. 6 kWh per day were considered. PEV aggregate load profiles from previous work were combined with vehicle population data to generate hourly loads on a regional basis. A transition from consumer-controlled charging toward utility-controlled charging was assumed such that by 2050 approximately 45% of the transportation energy demands could be delivered across four daily time slices under optimal control from the utility?s perspective. This electrified transportation analysis resulted in an estimate for both the flexible load and fixed load shapes on a regional basis that may evolve under two PEV market penetration scenarios.

Markel, T.; Mai, T.; Kintner-Meyer, M.

2010-12-01T23:59:59.000Z

417

An Adaptive Threshold Load Balancing Scheme for the End-to-End Reconfigurable System  

Science Conference Proceedings (OSTI)

In this paper, an adaptive threshold load balancing (ATLB) scheme is proposed for the joint load control (JOLDC) in the end-to-end reconfigurable system. The dynamic threshold based on heterogeneous load measurement is designed to adapt to varying load ... Keywords: Heterogeneous, Load balancing, Reconfigurability, Terminal selection, Vertical handover

Yongjing Zhang; Kui Zhang; Cheng Chi; Yang Ji; Zhiyong Feng; Ping Zhang

2008-07-01T23:59:59.000Z

418

Fuzzy rule-based methodology for residential load behaviour forecasting during power systems restoration  

Science Conference Proceedings (OSTI)

Inadequate load pickup during power system restoration can lead to overload and underfrequency conditions, and even restart the blackout process, due to thermal energy losses. Thus, load behaviour estimation during restoration is desirable to avoid inadequate ... Keywords: artificial intelligence, energy management systems, fuzzy logic, load behaviour estimation, power system distribution, power system restoration, residential load forecasting, thermostatically controlled loads

Lia Toledo Moreira Mota; Alexandre Assis Mota; Andre Luiz Morelato Franca

2005-04-01T23:59:59.000Z

419

Using Load Transformations for the Specification of Arrival Processes in Simulation and Analysis  

Science Conference Proceedings (OSTI)

In this paper the innovative approach of load transformation is used to derive valid load models for secondary loads in computer networks, as they can be observed at lower-layer interfaces of protocol stacks. We apply the technique of load transformation ... Keywords: Markov models, computer networks, load transformation, simulation tools, workload modeling

Stephan Heckmüller; Bernd E. Wolfinger

2009-08-01T23:59:59.000Z

420

A three phase load flow algorithm for Shipboard Power Systems  

E-Print Network (OSTI)

Load Flow (Power Flow) is the determination of the steady state operating conditions for the system. This is a very important tool utilized by many real time applications in power systems. Traditional load flow methods, which incorporate Gauss-Seidel and/or Newton Raphson techniques, were primarily developed for transmission system analysis. Distribution load flow analysis must incorporate its unique characteristics such as unbalanced loads, distributed loads, radial network structure, and one, two, or three phase lines. Also, there are a variety of components included in distribution systems such as switches, transformers, voltage regulators, and distributed generators. Therefore, the traditional methods cannot be directly applied to distribution systems since the assumptions made for transmission systems are not valid for the unique characteristics of distribution systems. A Shipboard Power System (SPS) is a finite inertia electric power system. The generation, transmission, and distribution systems in SPSs are tightly coupled. In reality, the transmission system consists of the lines that interconnect the generator buses in a ring configuration. The distribution system consists of lines, transformers, and loads connected in a radial configuration. When analyzing a SPS, its distinct characteristics must be taken into consideration. Therefore, just as transmission and distribution systems have unique methods of analysis, SPSs also need a unique method of analysis. A load flow algorithm for a SPS must consider its distribution system characteristics as well as the unique characteristics of SPSs. The work presented in this thesis discussed a load flow algorithm developed for Shipboard Power Systems and terrestrial wye and delta connected radial distribution systems. The issues in developing a load flow algorithm for a SPS are addressed and the solution is presented. This solution combines three methods that addressed the issues of multiple sources, ring configuration, and radial load flow. This algorithm was tested on the IEEE 37 Bus Radial Distribution Test Feeder and a simplified Shipboard Power Test System developed by researchers in the Power System Automation Laboratory. The results produced minimal percent error when compared to the actual output results.

Medina-Calder?on, M?onica M

2003-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "loading front loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Measured electric hot water standby and demand loads from Pacific Northwest homes. End-Use Load and Consumer Assessment Program  

SciTech Connect

The Bonneville Power Administration began the End-Use Load and Consumer Assessment Program (ELCAP) in 1983 to obtain metered hourly end-use consumption data for a large sample of new and existing residential and commercial buildings in the Pacific Northwest. Loads and load shapes from the first 3 years of data fro each of several ELCAP residential studies representing various segments of the housing population have been summarized by Pratt et al. The analysis reported here uses the ELCAP data to investigate in much greater detail the relationship of key occupant and tank characteristics to the consumption of electricity for water heating. The hourly data collected provides opportunities to understand electricity consumption for heating water and to examine assumptions about water heating that are critical to load forecasting and conservation resource assessments. Specific objectives of this analysis are to: (A) determine the current baseline for standby heat losses by determining the standby heat loss of each hot water tank in the sample, (B) examine key assumptions affecting standby heat losses such as hot water temperatures and tank sizes and locations, (C) estimate, where possible, impacts on standby heat losses by conservation measures such as insulating tank wraps, pipe wraps, anticonvection valves or traps, and insulating bottom boards, (D) estimate the EF-factors used by the federal efficiency standards and the nominal R-values of the tanks in the sample, (E) develop estimates of demand for hot water for each home in the sample by subtracting the standby load from the total hot water load, (F) examine the relationship between the ages and number of occupants and the hot water demand, (G) place the standby and demand components of water heating electricity consumption in perspective with the total hot water load and load shape.

Pratt, R.G.; Ross, B.A.

1991-11-01T23:59:59.000Z

422

FY 93 Thermal Loading Systems Study Final Report  

Science Conference Proceedings (OSTI)

The objective of the Mined Geologic Disposal System (MGDS) Thermal Loading Systems Study being conducted by the is to identify a thermal strategy that will meet the performance requirements for waste isolation and will be safe and licensable. Specifically, both postclosure and preclosure performance standards must be met by the thermal loading strategy ultimately selected. In addition cost and schedule constraints must be considered. The Systems Engineering approach requires structured, detailed analyses that will ultimately provide the technical basis for the development, integration, and evaluation of the overall system, not just a subelement of that system. It is also necessary that the systems study construct options from within the range that are allowed within the current legislative and programmatic framework. For example the total amount of fuel that can legally be emplaced is no more than 70,000 metric tons of uranium (MTU) which is composed of 63,000 MTU spent fuel and 7,000 MTU of defense high level waste. It is the intent of this study to begin the structured development of the basis for a thermal loading decision. However, it is recognized that to be able to make a final decision on thermal loading will require underground data on the effects of heating as well as a suite of ''validated'' models. It will be some time before these data and models are available to the program. Developing a final, thermal loading decision will, therefore, be an iterative process. In the interim, the objective of the thermal loading systems study has been to utilize the information available to assess the impact of thermal loading. Where technical justification exists, recommendations to narrow the range of thermal loading options can be made. Additionally, recommendations as to the type of testing and accuracy of the testing needed to establish the requisite information will be made. A constraint on the ability of the study to select an option stems from the lack of primary hard data, uncertainties in derived data, unsubstantiated models, and the inability to fully consider simultaneously coupled processes. As such, the study must rely on idealized models and available data to compare the thermal loading options. This report presents the findings of the FY 1993 MGDS Thermal Loading Systems Study. The objectives of the study were to: (1) if justified, place bounds on the thermal loading which would establish the loading that is ''too hot''; (2) ''grade'' or evaluate the performance as a function of thermal loading of the potential repository to contain high level spent nuclear fuel against performance criteria; (3) evaluate the performance of the various options with respect to cost, safety, and operability; and (4) recommend the additional types of tests and/or analyses to be conducted to provide the necessary information for a thermal loading selection.

S.F. Saterlie

1994-08-29T23:59:59.000Z

423

Electrical load management for the California water system  

DOE Green Energy (OSTI)

To meet its water needs California has developed an extensive system for transporting water from areas with high water runoff to areas with high water demand. This system annually consumes more than 6 billion kilowatt hours (kWh) of electricity for pumping water and produces more than 12 billion kWh/year of hydroelectric power. From the point of view of energy conservation, the optimum operation of the California water supply system would require that pumping be done at night and generation be done during the day. Night pumping would reduce electric power peak load demand and permit the pumps to be supplied with electricity from ''base load'' generating plants. Daytime hydro power generation would augment peak load power generation by fossil-fuel power plants and save fuel. The technical and institutional aspects of this type of electric power load management for water projects are examined for the purpose of explaining some of the actions which might be pursued and to develop recommendations for the California Energy Resources Conservation and Development Commission (ERCDC). The California water supply system is described. A brief description is given of various energy conservation methods, other than load management, that can be used in the management of water resources. An analysis of load management is presented. Three actions for the ERCDC are recommended: the Commission should monitor upcoming power contract negotiations between the utilities and the water projects; it should determine the applicability of the power-pooling provisions of the proposed National Energy Act to water systems; and it should encourage and support detailed studies of load management methods for specific water projects.

Krieg, B.; Lasater, I.; Blumstein, C.

1977-07-01T23:59:59.000Z

424

Transportation Electrification Load Development For a Renewable Future Analysis  

SciTech Connect

Electrification of the transportation sector offers the opportunity to significantly reduce petroleum consumption. The transportation sector accounts for 70% of US petroleum consumption. The transition to electricity as a transportation fuel will create a new load for electricity generation. In support of a recent US Department of Energy funded activity that analyzed a future generation scenario with high renewable energy technology contributions, a set of regional hourly load profiles for electrified vehicles were developed for the 2010 to 2050 timeframe. These load profiles with their underlying assumptions will be presented in this paper. The transportation electrical energy was determined using regional population forecast data, historical vehicle per capita data, and market penetration growth functions to determine the number of plug-in electric vehicles (PEVs) in each analysis region. Two market saturation scenarios of 30% of sales and 50% of sales of PEVs consuming on average {approx}6 kWh per day were considered. Results were generated for 3109 counties and were consolidated to 134 Power Control Areas (PCA) for the use NREL's's regional generation planning analysis tool ReEDS. PEV aggregate load profiles from previous work were combined with vehicle population data to generate hourly loads on a regional basis. A transition from consumer-controlled charging toward utility-controlled charging was assumed such that by 2050 approximately 45% of the transportation energy demands could be delivered across 4 daily time slices under optimal control from the utility perspective. No other literature has addressed the potential flexibility in energy delivery to electric vehicles in connection with a regional power generation study. This electrified transportation analysis resulted in an estimate for both the flexible load and fixed load shapes on a regional basis that may evolve under two PEV market penetration scenarios. EVS25 Copyright.

Markel, Tony; Mai, Trieu; Kintner-Meyer, Michael CW

2010-09-30T23:59:59.000Z

425

Development and application of the spatially explicit load enrichment calculation tool (select) to determine potential E. coli loads in watersheds  

E-Print Network (OSTI)

According to the USEPA National Section 303(d) List Fact Sheet, bacterial pathogens are the leading cause of water quality impairments in Texas. The automated Spatially Explicit Load Enrichment Calculation Tool (SELECT) uses spatially variable factors such as land use, soil condition, and distance to streams to characterize pathogen sources across a watershed. The results support development of Total Maximum Daily Loads (TMDLs) where bacterial contamination is of concern. SELECT calculates potential E. coli loads by distributing the contributing source populations across suitable habitats, applying a fecal production rate, and then aggregating the potential load to the subwatersheds. SELECT provides a Graphical User Interface (GUI), developed in Visual Basic for Applications (VBA) within ArcGIS 9.X, where project parameters can be adjusted for various pollutant loading scenarios. A new approach for characterizing E. coli loads resulting from on-site wastewater treatment systems (OWTSs) was incorporated into the SELECT methodology. The pollutant connectivity factor (PCF) module was created to identify areas potentially contributing E. coli loads to waterbodies during runoff events by weighting the influence of potential loading, runoff potential, and travel distance. Simulation results indicate livestock and wildlife are potentially contributing large amounts of E. coli in the Lake Granbury Watershed in areas where these contributing sources are not currently monitored for E. coli. The bacterial water quality violations near Lake Granbury are most likely the result of malfunctioning OWTSs and pet waste in the runoff. The automated SELECT was verified by characterizing the potential E. coli loading in the Plum Creek Watershed and comparing to results from a prior study (Teague, 2007). The E. coli potential load for the watershed was lower than the previous study due to major differences in assumptions. Comparing the average ranked PCF estimated by physical properties of the watershed with the statistical clustering of watershed characteristics provided similar groupings. SELECT supports the need to evaluate each contributing source separately to effectively allocate site specific best management practices (BMPs). This approach can be used as a screening step for determining areas where detailed investigation is merited. SELECT in conjunction with PCF and clustering analysis can assist decision makers develop Watershed Protection Plans (WPPs) and determine TMDLs.

Riebschleager, Kendra Jean

2008-08-01T23:59:59.000Z

426

Commercial and Residential Hourly Load Data Now Available on OpenEI! |  

Open Energy Info (EERE)

Commercial and Residential Hourly Load Data Now Available on OpenEI! Commercial and Residential Hourly Load Data Now Available on OpenEI! Home > Groups > Utility Rate Sfomail's picture Submitted by Sfomail(48) Member 17 May, 2013 - 12:03 building load building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Load data Image source: NREL I am pleased to announce that simulated hourly residential and commercial building load datasets are now available on OpenEI. These datasets are available for all TMY3 locations in the United States. They contain hourly load profile data for 16 commercial building types (based off the DOE commercial reference building models) and residential buildings (based off the Building America House Simulation Protocols). In addition to various

427

Statistical Analysis of Baseline Load Models for Non-Residential Buildings  

E-Print Network (OSTI)

estimation of the baseline load profile. In this paper, weDemand response, Baseline load profile, Impacts estimationto as the baseline load profile (or baseline) and is key to

Coughlin, Katie

2012-01-01T23:59:59.000Z

428

To forecast short-term load in electric power system based on FNN  

Science Conference Proceedings (OSTI)

Electric power system load forecasting plays an important part in the Energy Management System (EMS), which has a great effect on the operating, controlling and planning of power system. Accurate load forecasting, especially short-term load forecasting, ...

Yueli Hu; Huijie Ji; Xiaolong Song

2009-08-01T23:59:59.000Z

429

Influence of raised floor on zone design cooling load in commercial buildings.  

E-Print Network (OSTI)

design day zone cooling load profile is evaluated for anThe zone cooling load profiles and the thermal performanceaffects the zone cooling load profile and the peak cooling

Schiavon, Stefano; Lee, Kwang Ho; Bauman, Fred; Webster, Tom

2010-01-01T23:59:59.000Z

430

Development of a simplified cooling load design tool for underfloor air distribution (UFAD) systems.  

E-Print Network (OSTI)

in design day cooling load profiles for OH and UFAD systems;in design day cooling load profiles for OH and UFAD systems;showed that the cooling load profiles for UFAD and OH are

Schiavon, Stefano; Lee, Kwang Ho; Bauman, Fred; Webster, Tom

2010-01-01T23:59:59.000Z

431

Simplified calculation method for design cooling loads in underfloor air distribution (UFAD) systems  

E-Print Network (OSTI)

design day cooling load profiles, (2) impact of a thermallyday peak zone cooling load profile for UFAD and a well-mixedaffects the cooling load profiles, therefore it is possible

Schiavon, Stefano; Lee, Kwang Ho; Bauman, Fred; Webster, Tom

2010-01-01T23:59:59.000Z

432

IEP - Water-Energy Interface: Total Maximum Daily Load Page  

NLE Websites -- All DOE Office Websites (Extended Search)

Total Maximum Daily Loads (TMDLs) Total Maximum Daily Loads (TMDLs) The overall goal of the Clean Water Act is to "restore and maintain the chemical, physical, and biological integrity of the Nation’s waters." In 1999, EPA proposed changes to Section 303(d), to establish Total Maximum Daily Loads (TMDLs) for watersheds that do not meet this goal. The TMDL is the highest amount of a given pollutant that is permissible in that body of water over a given period of time. TMDLs include both waste load allocation (WLA) for point sources and load allocations for non-point sources. In Appalachia, acid mine drainage (AMD) is the single most damaging non-point source. There is also particular concern of the atmospheric deposition of airborne sulfur, nitrogen, and mercury compounds. States are currently in the process of developing comprehensive lists of impaired waters and establishing TMDLs for those waters. EPA has recently proposed a final rule that will require states to develop TMDLs and implement plans for improving water quality within the next 10 years. Under the new rule, TMDL credits could be traded within a watershed.

433

Wind loading on solar concentrators: some general considerations  

DOE Green Energy (OSTI)

A survey has been completed to examine the problems and complications arising from wind loading on solar concentrators. Wind loading is site specific and has an important bearing on the design, cost, performance, operation and maintenance, safety, survival, and replacement of solar collecting systems. Emphasis herein is on paraboloidal, two-axis tracking systems. Thermal receiver problems also are discussed. Wind characteristics are discussed from a general point of view; current methods for determining design wind speed are reviewed. Aerodynamic coefficients are defined and illustrative examples are presented. Wind tunnel testing is discussed, and environmental wind tunnels are reviewed; recent results on heliostat arrays are reviewed as well. Aeroelasticity in relation to structural design is discussed briefly. Wind loads, i.e., forces and moments, are proportional to the square of the mean wind velocity. Forces are proportional to the square of concentrator diameter, and moments are proportional to the cube of diameter. Thus, wind loads have an important bearing on size selection from both cost and performance standpoints. It is concluded that sufficient information exists so that reasonably accurate predictions of wind loading are possible for a given paraboloidal concentrator configuration, provided that reliable and relevant wind conditions are specified. Such predictions will be useful to the design engineer and to the systems engineer as well. Information is lacking, however, on wind effects in field arrays of paraboloidal concentrators. Wind tunnel tests have been performed on model heliostat arrays, but there are important aerodynamic differences between heliostats and paraboloidal dishes.

Roschke, E. J.

1984-05-01T23:59:59.000Z

434

Behavior of Capstone and Honeywell microturbine generators during load changes  

SciTech Connect

This report describes test measurements of the behavior of two microturbine generators (MTGs) under transient conditions. The tests were conducted under three different operating conditions: grid-connect; stand-alone single MTG with load banks; and two MTGs running in parallel with load banks. Tests were conducted with both the Capstone 30-kW and Honeywell Parallon 75-kW MTGs. All tests were conducted at the Southern California Edison /University of California, Irvine (UCI) test facility. In the grid-connected mode, several test runs were conducted with different set-point changes both up and down and a start up and shutdown were recorded for each MTG. For the stand-alone mode, load changes were initiated by changing load-bank values (both watts and VARs). For the parallel mode, tests involved changes in the load-bank settings as well as changes in the power set point of the MTG running in grid-connect mode. Detailed graphs of the test results are presented. It should be noted that these tests were done using a specific hardware and software configuration. Use of different software and hardware could result in different performance characteristics for the same units.

Yinger, Robert J.

2001-07-01T23:59:59.000Z

435

Self locking coupling mechanism for engaging and moving a load  

DOE Patents (OSTI)

A coupling mechanism for engaging and lifting a load has a housing with a guide passage for receiving a knob which is secured to the load through a neck of smaller diameter. A hollow ball in the housing has an opening which receives the knob and the ball is then turned to displace the opening from the housing passage and to cause the neck to enter a slot in the ball thereby securing the load to the coupling mechanism as elements of the housing block travel of the neck back into the opening when the ball is turned to the load holding orientation. As engagement of the load and locking of the coupling mechanism are accomplished simultaneously by the same ball motion, operation is simplified and reliability is greatly increased. The ball is preferably turned by a motor through worm gearing and the coupling mechanism may be controlled from a remote location. Among other uses, the coupling mechanism is adaptable to the handling of spent nuclear reactor fuel elements.

Wood, R.L.; Casamajor, A.B.; Parsons, R.E.

1980-09-12T23:59:59.000Z

436

Analysis of the Thermal Loads on the KSTAR Cryogenic System  

SciTech Connect

A large-scale helium refrigeration system is one of the key components for the KSTAR (Korea Superconducting Tokamak Advanced Research) device. In the design of the refrigeration system, an estimation of the thermal loads on the cold mass is an important issue according to the operation scenario. The cold mass of the KSTAR device is about 250 tons including 30 superconducting (SC) coils and the magnet structure. In addition to the static thermal loads, pulsed thermal loads to the refrigeration system have been considered in the operation stage. The main pulsed thermal loads on magnet system are AC losses in the SC coils and eddy current losses in the magnet structure that depend on the magnetic field variation rate. The nuclear radiation loss due to plasma pulse operation is also considered. The designed cooling capacity of the refrigeration system is estimated to be about 9 kW at 4.5 K isothermal. In this paper, calculation of the various kinds of thermal loads on KSTAR cryogenic system and design of the large-scale helium refrigeration system are presented.

Kim, Y.S.; Oh, Y.K.; Kim, W.C.; Park, Y.M.; Lee, Y.J.; Jin, S.B.; Sa, J.W.; Choi, C.H.; Cho, K.W.; Bak, J.S.; Lee, G.S. [Korea Basic Science Institute, Yusung-Ku, Daejeon 305-806 (Korea, Republic of)

2004-06-23T23:59:59.000Z

437

New generation loading/mooring/storage (LMS) production platform  

SciTech Connect

A new generation loading/mooring/storage (LMS) production platform designed by Sumitomo Heavy Industries Ltd. and the Aker Group has been patented in the U.S. and several other countries by Mobil Oil Corp. The LMS vessel is a semisubmersible with ship mooring and loading facilities atop a box-shaped crude oil storage structure which floats well below the waterline. A capability is provided for loading tankers with 800,000 bbl of crude oil in only 12 hr. There are 15 dual-purpose cargo/ballast tanks in the lower section, with a control tower over the center tank. Upper and lower cargo tanks in the tower are each divided into three sections to provide additional crude handling flexibility. The LMS operates at a constant draft. Crude pumped into the LMS from the producing platform enters the tower tanks and is then transferred to a lower tank in which a diagonal suspended synthetic rubber diaphragm separates the oil from clean water ballast. During ship loading, the pressure of seawater reentering the dual tanks pushes the crude to the tower, where cargo pumps deliver it to the loading vessel.

1978-07-01T23:59:59.000Z

438

The evaluation of a turbulent loads characterization system  

DOE Green Energy (OSTI)

In this paper we discuss an on-line turbulent load characterization system that has been designed to acquire loading spectra from turbines of the same design operating in several different environments and from different turbine designs operating in the same environment. This System simultaneously measures the rainflow-counted alternating and mean loading spectra and the hub-height turbulent mean shearing stress and atmospheric stability associated with the turbulent inflow. We discuss the theory behind the measurement configuration and the results of proof-of-concept testing recently performed at the National Wind Technology Center (NWTC) using a Bergey EXCEL-S 10-kW wind turbine. The on-line approach to characterizing the load spectra and the inflow turbulent scaling parameter produces results that are consistent with other measurements. The on-line approximation of the turbulent shear stress or friction velocity u* also is considered adequate. The system can be used to characterize turbulence loads during turbine deployment in a wide variety of environments. Using the WISPER protocol, we found that a wide-range, variable-speed turbine will accumulate a larger number of stress cycles in the low-cycle, high-amplitude (LCHA) region when compared with a constant speed rotor under similar inflow conditions.

Kelley, N.D.; McKenna, H.E. [National Renewable Energy Lab., Golden, CO (United States)

1996-01-01T23:59:59.000Z

439

Using Whole-Building Electric Load Data in Continuous orRetro...  

NLE Websites -- All DOE Office Websites (Extended Search)

Whole-Building Electric Load Data in Continuous or Retro-Commissioning Title Using Whole-Building Electric Load Data in Continuous or Retro-Commissioning Publication Type...

440

HVAC Right-Sizing Part 1-Calculating Loads | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

-Calculating Loads HVAC Right-Sizing Part 1-Calculating Loads During this webinar, Building America Research Team IBACOS highlighted the key criteria required to create accurate...

Note: This page contains sample records for the topic "loading front loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

HVAC Right-Sizing Part 1: Calculating Loads | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

: Calculating Loads HVAC Right-Sizing Part 1: Calculating Loads This webinar, presented by IBACOS (a Building America Research Team) will highlight the key criteria required to...

442

T-573: Windows Remote Desktop Client DLL Loading Error Lets Remote...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

73: Windows Remote Desktop Client DLL Loading Error Lets Remote Users Execute Arbitrary Code T-573: Windows Remote Desktop Client DLL Loading Error Lets Remote Users Execute...

443

Building Energy Software Tools Directory: Popolo Utility Load Calculation  

NLE Websites -- All DOE Office Websites (Extended Search)

Popolo Utility Load Calculation Popolo Utility Load Calculation Popolo Utility Load Calculation is a collection of classes for calculating various heat transfer phenomena. The routines have been written from scratch in C#, and present a modern Applications Programming Interface (API) for .NET Framework programmers, allowing wrappers to be written for very high level languages. It contains classes to calculate solid conduction, convective heat transfer near wall surfaces, air ventilation, radiative heat balance of wall surfaces, transmitted solar radiation through a window, and so on. Users should build up these classes to simulate a whole complex building system. A sample source code to build test cases of BESTEST are provided. Since all the source code is distributed under the GNU General Public License, they can be freely

444

An effective loading method of americium targets in fast reactors  

Science Conference Proceedings (OSTI)

Recently, the development of target fuel with high americium (Am) content has been launched for the reduction of the overall fuel fabrication cost of the minor actinide (MA) recycling. In the framework of the development, this study proposes an effective loading method of Am targets in fast reactors. As a result of parametric survey calculations, we have found the ring-shaped target loading pattern between inner and outer core regions. This loading method is satisfactory both in core characteristics and in MA transmutation property. It should be noted that the Am targets can contribute to the suppression of the core power distribution change due to burnup. The major drawback of Am target is the production of helium gas. A target design modification by increasing the cladding thickness is found to be the most feasible measure to cope with the helium production. (authors)

Ohki, Shigeo; Sato, Isamu; Mizuno, Tomoyasu; Hayashi, Hideyuki; Tanaka, Kenya [Japan Atomic Energy Agency, 4002, Narita-cho, O-arai-machi, Higashi-Ibaraki-gun, Ibaraki 311-1393 (Japan)

2007-07-01T23:59:59.000Z

445

Property:Geothermal/LoadFactor | Open Energy Information  

Open Energy Info (EERE)

LoadFactor LoadFactor Jump to: navigation, search This is a property of type Number. Pages using the property "Geothermal/LoadFactor" Showing 25 pages using this property. (previous 25) (next 25) 4 4 UR Guest Ranch Pool & Spa Low Temperature Geothermal Facility + 0.76 + A Ace Development Aquaculture Low Temperature Geothermal Facility + 0.8 + Agua Calientes Trailer Park Space Heating Low Temperature Geothermal Facility + 0.29 + Alive Polarity's Murrietta Hot Spring Pool & Spa Low Temperature Geothermal Facility + 0.8 + Americulture Aquaculture Low Temperature Geothermal Facility + 0.81 + Aq Dryers Agricultural Drying Low Temperature Geothermal Facility + 0.25 + Aqua Caliente County Park Pool & Spa Low Temperature Geothermal Facility + 0.68 +

446

Used Nuclear Fuel Loading and Structural Performance Under Normal  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Nuclear Fuel Loading and Structural Performance Under Normal Nuclear Fuel Loading and Structural Performance Under Normal Conditions of Transport - Demonstration of Approach and Results of Used Fuel Performance Characterization Used Nuclear Fuel Loading and Structural Performance Under Normal Conditions of Transport - Demonstration of Approach and Results of Used Fuel Performance Characterization This report provides results of the initial demonstration of the modeling capability developed to perform preliminary deterministic evaluations of moderate-to-high burnup used nuclear fuel (UNF) mechanical performance under normal conditions of storage (NCS) and normal conditions of transport (NCT) conditions. This report also provides results from the sensitivity studies, and discussion on the long-term goals and objectives of this

447

Definition: Real-Time Load Measurement And Management | Open Energy  

Open Energy Info (EERE)

Management Management Jump to: navigation, search Dictionary.png Real-Time Load Measurement And Management This function provides real-time measurement of customer consumption and management of load through Advanced Metering Infrastructure (AMI) systems (smart meters, two-way communications) and embedded appliance controllers that help customers make informed energy use decisions via real-time price signals, time-of-use (TOU) rates, and service options.[1] Related Terms advanced metering infrastructure, time-of-use pricing, smart grid References ↑ SmartGrid.gov 'Description of Functions' An in LikeLike UnlikeLike You like this.Sign Up to see what your friends like. line Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Real-Time_Load_Measurement_And_Management&oldid=493115

448

Repository Reference Disposal Concepts and Thermal Load Management Analysis  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Repository Reference Disposal Concepts and Thermal Load Management Repository Reference Disposal Concepts and Thermal Load Management Analysis Repository Reference Disposal Concepts and Thermal Load Management Analysis A disposal concept consists of three parts: waste inventory (7 waste types examined), geologic setting (e.g., clay/shale, salt, crystalline, other sedimentary), and the engineering concept of operations (range of generic operational concepts examined). Two major categories for waste package emplacement modes are identified: 1) "open" where extended ventilation can remove heat for many years following waste emplacement underground; and 2) "enclosed" modes for clay/shale and salt media where waste packages are emplaced in direct or close contact with natural or engineered materials which may have temperature limits that constrain thermal

449

Analysis and Representation of Miscellaneous Electric Loads in NEMS -  

Gasoline and Diesel Fuel Update (EIA)

Analysis and Representation of Miscellaneous Electric Loads in NEMS Analysis and Representation of Miscellaneous Electric Loads in NEMS Release date: January 6, 2014 Miscellaneous Electric Loads (MELs) comprise a growing portion of delivered energy consumption in residential and commercial buildings. Recently, the growth of MELs has offset some of the efficiency gains made through technology improvements and standards in major end uses such as space conditioning, lighting, and water heating. Miscellaneous end uses, including televisions, personal computers, security systems, data center servers, and many other devices, have continued to penetrate into building-related market segments. Part of this proliferation of devices and equipment can be attributed to increased service demand for entertainment, computing, and convenience appliances.

450

Repository Reference Disposal Concepts and Thermal Load Management Analysis  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Repository Reference Disposal Concepts and Thermal Load Management Repository Reference Disposal Concepts and Thermal Load Management Analysis Repository Reference Disposal Concepts and Thermal Load Management Analysis A disposal concept consists of three parts: waste inventory (7 waste types examined), geologic setting (e.g., clay/shale, salt, crystalline, other sedimentary), and the engineering concept of operations (range of generic operational concepts examined). Two major categories for waste package emplacement modes are identified: 1) "open" where extended ventilation can remove heat for many years following waste emplacement underground; and 2) "enclosed" modes for clay/shale and salt media where waste packages are emplaced in direct or close contact with natural or engineered materials which may have temperature limits that constrain thermal

451

Energy Efficient Geographical Load Balancing via Dynamic Deferral of Workload  

E-Print Network (OSTI)

With the increasing popularity of Cloud computing and Mobile computing, individuals, enterprises and research centers have started outsourcing their IT and computational needs to on-demand cloud services. Recently geographical load balancing techniques have been suggested for data centers hosting cloud computation in order to reduce energy cost by exploiting the electricity price differences across regions. However, these algorithms do not draw distinction among diverse requirements for responsiveness across various workloads. In this paper, we use the flexibility from the Service Level Agreements (SLAs) to differentiate among workloads under bounded latency requirements and propose a novel approach for cost savings for geographical load balancing. We investigate how much workload to be executed in each data center and how much workload to be delayed and migrated to other data centers for energy saving while meeting deadlines. We present an offline formulation for geographical load balancing problem with dyna...

Adnan, Muhammad Abdullah; Gupta, Rajesh

2012-01-01T23:59:59.000Z

452

Model for Aggregated Water Heater Load Using Dynamic Bayesian Networks  

Science Conference Proceedings (OSTI)

The transition to the new generation power grid, or “smart grid”, requires novel ways of using and analyzing data collected from the grid infrastructure. Fundamental functionalities like demand response (DR), that the smart grid needs, rely heavily on the ability of the energy providers and distributors to forecast the load behavior of appliances under different DR strategies. This paper presents a new model of aggregated water heater load, based on dynamic Bayesian networks (DBNs). The model has been validated against simulated data from an open source distribution simulation software (GridLAB-D). The results presented in this paper demonstrate that the DBN model accurately tracks the load profile curves of aggregated water heaters under different testing scenarios.

Vlachopoulou, Maria; Chin, George; Fuller, Jason C.; Lu, Shuai; Kalsi, Karanjit

2012-07-19T23:59:59.000Z

453

Comparison of Wind Power and Load Forecasting Error Distributions: Preprint  

DOE Green Energy (OSTI)

The introduction of large amounts of variable and uncertain power sources, such as wind power, into the electricity grid presents a number of challenges for system operations. One issue involves the uncertainty associated with scheduling power that wind will supply in future timeframes. However, this is not an entirely new challenge; load is also variable and uncertain, and is strongly influenced by weather patterns. In this work we make a comparison between the day-ahead forecasting errors encountered in wind power forecasting and load forecasting. The study examines the distribution of errors from operational forecasting systems in two different Independent System Operator (ISO) regions for both wind power and load forecasts at the day-ahead timeframe. The day-ahead timescale is critical in power system operations because it serves the unit commitment function for slow-starting conventional generators.

Hodge, B. M.; Florita, A.; Orwig, K.; Lew, D.; Milligan, M.

2012-07-01T23:59:59.000Z

454

Status of Jefferson Lab's Load Locked Polarized Electron Beam  

DOE Green Energy (OSTI)

A new 100 kV load locked polarized electron gun has been built at Jefferson Lab. The gun is installed in a test stand on a beam line that resembles the first few meters of the CEBAF nuclear physics photoinjector. With this gun, a GaAs photocathode can be loaded from atmosphere, hydrogen cleaned, activated and taken to high voltage in less than 8 hours. The gun is a three chamber design, with all of the moving parts remaining at ground potential during gun operation. Studies of gun performance, photocathode life times, transverse emittance at high bunch charge, helicity correlated effects and beam polarizations from new photocathode samples will all be greatly facilitated by the use of this load locked gun.

M.L. Stutzman; P. Adderley; M. Baylac; J. Clark; A. Day; J. Grames; J. Hansknecht; M. Poelker

2002-09-01T23:59:59.000Z

455

Preliminary Investigation of Sulfur Loading in Hanford LAW Glass  

SciTech Connect

A preliminary estimate was developed for loading limits for high-sulfur low-activity waste (LAW) feeds that will be vitrified into borosilicate glass at the Hanford Site in the waste-cleanup effort. Previous studies reported in the literature were consulted to provide a basis for the estimate. The examination of previous studies led to questions about sulfur loading in Hanford LAW glass, and scoping tests were performed to help answer these questions. These results of these tests indicated that a formulation approach developed by Vienna and colleagues shows promise for maximizing LAW loading in glass. However, there is a clear need for follow-on work. The potential for significantly lowering the amount of LAW glass produced at Hanford (after the initial phase of processing) because of higher sulfur tolerances may outweigh the cost and effort required to perform the necessary testing.

Vienna, John D.; Hrma, Pavel R.; Buchmiller, William C.; Ricklefs, Joel S.

2004-04-01T23:59:59.000Z

456

Forecasting electricity load demand: analysis of the 2001 rationing period  

E-Print Network (OSTI)

CEPEL e UENF. Abstract. This paper studies the electricity load demand behavior during the 2001 rationing period, which was implemented because of the Brazilian energetic crisis. The hourly data refers to a utility situated in the southeast of the country. We use the model proposed by Soares and Souza (2003), making use of generalized long memory to model the seasonal behavior of the load. The rationing period is shown to have imposed a structural break in the series, decreasing the load at about 20%. Even so, the forecast accuracy is decreased only marginally, and the forecasts rapidly readapt to the new situation. The forecast errors from this model also permit verifying the public response to pieces of information released regarding the crisis.

Leonardo Rocha Souza; Lacir Jorge Soares; Leonardo Rocha Souza; Epge Fundação; Getúlio Vargas; Lacir Jorge Soares

2003-01-01T23:59:59.000Z

457

Energy Efficiency Indicators for High Electric-Load Buildings  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy Efficiency Indicators for High Electric-Load Buildings Energy Efficiency Indicators for High Electric-Load Buildings Speaker(s): Bernard Aebischer Date: February 6, 2003 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Kristina LaCommare Energy per unit of floor area is not an adequate indictor for energy efficiency in high electric-load buildings. For two activities, restaurants and computer centres, alternative indicators for energy efficiency are discussed. Prerequisites in order to be able to use these indicators in energy efficiency programmes are discussed. The opportunity of an internationally coordinated research activity is also presented. Since 1999, Dr. Bernard Aebischer has served as a senior scientist at CEPE (Centre for Energy Policy and Economics) of the Swiss Federal Institutes of

458

Preconditioning Outside Air: Cooling Loads from Building Ventilation  

E-Print Network (OSTI)

HVAC equipment manufacturers, specifiers and end users interacting in the marketplace today are only beginning to address the series of issues promulgated by the increased outside air requirements in ASHRAE Standard 62- 1989, "Ventilation for Acceptable Indoor Air Quality", that has cascaded into building codes over the early to mid 1990's. There has been a twofold to fourfold increase in outside air requirements for many commercial building applications, compared to the 1981 version of the standard. To mitigate or nullify these additional weather loads, outdoor air preconditioning technologies are being promoted in combination with conventional HVAC operations downstream as a means to deliver the required fresh air and control humidity indoors. Preconditioning is the term applied for taking outside air to the indoor air setpoint (dry bulb temperature and relative humidity). The large humidity loads from outside air can now be readily recognized and quantified at cooling design point conditions using the extreme humidity ratios/dew points presented in the ASHRAE Handbook of Fundamentals Chapter 26 "Climatic Design Information". This paper presents an annual index called the Ventilation Load Index (VLI), recently developed by the Gas Research Institute (GRI) that measures the magnitude of latent (and sensible) loads for preconditioning outside air to indoor space conditions over the come of an entire year. The VLI has units of ton-hrs/scfm of outside air. The loads are generated using new weather data binning software called ~BinMaker, also from GRI, that organizes the 239 city, 8760 hour by hour, TMY2 weather data into user selected bidtables. The VLI provides a simple methodology for accessing the cooling load impact of increased ventilation air volumes and a potential basis for defining a "humid" climate location.

Kosar, D.

1998-01-01T23:59:59.000Z

459

Fielding a Plug Load Self Audit -- A Case Study  

Science Conference Proceedings (OSTI)

This report summarizes the efforts of the Snohomish County Public Utility District and the Electric Power Research Institute (EPRI) in developing a low-cost and accurate plug load study. This project had the following three objectives: To use low-cost, self-installed metering equipment to collect and analyze end-use load data for a large number of residential customers, To develop a list of lessons learned about collecting end-use data that could be shared with other utility members conducting similar p...

2011-11-24T23:59:59.000Z

460

A new aggregation method for determining composite load characteristics  

SciTech Connect

A new aggregation method for determining load characteristics for representation in computer simulations is proposed. In support of the new method, a mathematical derivation is presented. Also, results are compared with models obtained by using the EPRI/University of Texas at Arlington method and field tests. The application of the proposed method is simpler than existing methods in that it does not require field tests or the use of curve fitting techniques. The procedure should be of primary interest to transmission system planners involved in load flow and dynamic stability simulations of power systems.

Rideiro, J.R.; Lange, F.J.

1982-08-01T23:59:59.000Z

Note: This page contains sample records for the topic "loading front loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

ENERGY STAR Building Upgrade Manual Chapter 7: Supplemental Load Reduction  

NLE Websites -- All DOE Office Websites (Extended Search)

7: Supplemental Load 7: Supplemental Load Reduction Secondary menu About us Press room Contact Us Portfolio Manager Login Facility owners and managers Existing buildings Commercial new construction Industrial energy management Small business Service providers Service and product providers Verify applications for ENERGY STAR certification Design commercial buildings Energy efficiency program administrators Commercial and industrial program sponsors Associations State and local governments Federal agencies Tools and resources Training In This Section Campaigns Commercial building design Communications resources Energy management guidance Financial resources Portfolio Manager Products and purchasing Recognition Research and reports Service and product provider (SPP) resources Success stories Target Finder

462

Direct versus Facility Centric Load Control for Automated Demand Response  

SciTech Connect

Direct load control (DLC) refers to the scenario where third party entities outside the home or facility are responsible for deciding how and when specific customer loads will be controlled in response to Demand Response (DR) events on the electric grid. Examples of third parties responsible for performing DLC may be Utilities, Independent System Operators (ISO), Aggregators, or third party control companies. DLC can be contrasted with facility centric load control (FCLC) where the decisions for how loads are controlled are made entirely within the facility or enterprise control systems. In FCLC the facility owner has more freedom of choice in how to respond to DR events on the grid. Both approaches are in use today in automation of DR and both will continue to be used in future market segments including industrial, commercial and residential facilities. This paper will present a framework which can be used to differentiate between DLC and FCLC based upon where decisions are made on how specific loads are controlled in response to DR events. This differentiation is then used to compare and contrast the differences between DLC and FCLC to identify the impact each has on:(1)Utility/ISO and third party systems for managing demand response, (2)Facility systems for implementing load control, (3)Communications networks for interacting with the facility and (4)Facility operators and managers. Finally a survey of some of the existing DR related specifications and communications standards is given and their applicability to DLC or FCLC. In general FCLC adds more cost and responsibilities to the facilities whereas DLC represents higher costs and complexity for the Utility/ISO. This difference is primarily due to where the DR Logic is implemented and the consequences that creates. DLC may be more certain than FCLC because it is more predictable - however as more loads have the capability to respond to DR signals, people may prefer to have their own control of end-use loads and FCLC systems. Research is needed to understand the predictability of FCLC which is related to the perceived value of the DR from the facility manager or home owner's perspective.

Koch, Ed; Piette, Mary Ann

2009-11-06T23:59:59.000Z

463

Overhead Line Loading Program (OHLOAD) Version 2.0  

Science Conference Proceedings (OSTI)

OHLOAD allows the user to calculate thermal ratings and conductor temperatures for overhead power transmission lines. EPRI's Overhead Line Loading Program (OHLOAD 2.0) calculates bare conductor temperatures and thermal ratings based on user-specified weather parameters and user-specified electrical load. The calculation methods available in OHLOAD are based on various CIGRE, IEEE, and EPRI documents. WindowsXP, Vista, and Windows 7. The PC must have at least 20 MB of free disk space and a Pentium II proc...

2012-05-01T23:59:59.000Z

464

Dry method for recycling iodine-loaded silver zeolite  

DOE Green Energy (OSTI)

Fission product iodine is removed from a waste gas stream and stored by passing the gas stream through a bed of silver-exchanged zeolite until the zeolite is loaded with iodine, passing dry hydrogen gas through the bed to remove the iodine and regenerate the bed, and passing the hydrogen stream containing the hydrogen iodide thus formed through a lead-exchanged zeolite which adsorbs the radioactive iodine from the gas stream and permanently storing the lead-exchanged zeolite loaded with radioactive iodine.

Thomas, Thomas R. (Idaho Falls, ID); Staples, Bruce A. (Idaho Falls, ID); Murphy, Llewellyn P. (Idaho Falls, ID)

1978-05-09T23:59:59.000Z

465

Influence Of Lateral Load Distributions On Pushover Analysis Effectiveness  

SciTech Connect

The effectiveness of two simple load distributions for pushover analysis recently proposed by the authors is investigated through a comparative study, involving static and dynamic analyses of seismic response of eccentrically braced frames. It is shown that in the upper floors only multimodal pushover procedures provide results close to the dynamic profile, while the proposed load patterns are always conservative in the lower floors. They over-estimate the seismic response less than the uniform distribution, representing a reliable alternative to the uniform or more sophisticated adaptive procedures proposed by seismic codes.

Colajanni, P.; Potenzone, B. [Dipartimento di Ingegneria Civile, Universita di Messina, Contrada Di Dio, S. Agata, 98166 Messina (Italy)

2008-07-08T23:59:59.000Z

466

Feasibility of dc transmission with forced commutation to remote loads  

SciTech Connect

Previous researchers have analysed the forced commutated HVDC inverter and have concluded that it could be used to meet the reactive power at the inverter terminals. This investigation is a further technical appraisal involving a two terminal transmission scheme to a remote load with no ac generation at the load. Several possible inverter configurations are discussed. An electromagnetic transients program is used to model the system and simulate such aspects as start up, ac and dc faults and speed of response to voltage and frequency controls. The results indicate that such a scheme is indeed technically feasible and may be quite attractive from an economic and reliability point of view.

Turanli, H.M.; Menzies, R.W.; Woodford, D.A.

1984-06-01T23:59:59.000Z

467

Using measured equipment load profiles to "right-size" HVAC systems and reduce energy use in laboratory buildings (Pt. 2)  

E-Print Network (OSTI)

Using measured equipment load profiles to “right-size” HVAClighting and occupancy load profiles in all the spaces wereintensity” equipment load profile, while the remaining zones

Mathew, Paul; Greenberg, Steve; Frenze, David; Morehead, Michael; Sartor, Dale; Starr, William

2008-01-01T23:59:59.000Z

468

Spinning Reserve From Hotel Load Response: Initial Progress  

SciTech Connect

This project was motivated by the fundamental match between hotel space conditioning load response capability and power system contingency response needs. As power system costs rise and capacity is strained demand response can provide a significant system reliability benefit at a potentially attractive cost. At ORNL s suggestion, Digital Solutions Inc. adapted its hotel air conditioning control technology to supply power system spinning reserve. This energy saving technology is primarily designed to provide the hotel operator with the ability to control individual room temperature set-points based upon occupancy (25% to 50% energy savings based on an earlier study [Kirby and Ally, 2002]). DSI added instantaneous local load shedding capability in response to power system frequency and centrally dispatched load shedding capability in response to power system operator command. The 162 room Music Road Hotel in Pigeon Forge Tennessee agreed to host the spinning reserve test. The Tennessee Valley Authority supplied real-time metering equipment in the form of an internet connected Dranetz-BMI power quality meter and monitoring expertise to record total hotel load during both normal operations and test results. The Sevier County Electric System installed the metering. Preliminary testing showed that hotel load can be curtailed by 22% to 37% depending on the outdoor temperature and the time of day. These results are prior to implementing control over the common area air conditioning loads. Testing was also not at times of highest system or hotel loading. Full response occurred in 12 to 60 seconds from when the system operator s command to shed load was issued. The load drop was very rapid, essentially as fast as the 2 second metering could detect, with all units responding essentially simultaneously. Load restoration was ramped back in over several minutes. The restoration ramp can be adjusted to the power system needs. Frequency response testing was not completed. Initial testing showed that the units respond very quickly. Problems with local power quality generated false low frequency signals which required testing to be stopped. This should not be a problem in actual operation since the frequency trip points will be staggered to generate a droop curve which mimics generator governor response. The actual trip frequencies will also be low enough to avoid power quality problems. The actual trip frequencies are too low to generate test events with sufficient regularity to complete testing in a reasonable amount of time. Frequency response testing will resume once the local power quality problem is fully understood and reasonable test frequency settings can be determined. Overall the preliminary testing was extremely successful. The hotel response capability matches the power system reliability need, being faster than generation response and inherently available when the power system is under the most stress (times of high system and hotel load). Periodic testing is scheduled throughout the winter and spring to characterize hotel response capability under a full range of conditions. More extensive testing will resume when summer outdoor temperatures are again high enough to fully test hotel response.

Kueck, John D [ORNL; Kirby, Brendan J [ORNL

2008-11-01T23:59:59.000Z

469

Cognitive load research and semantic apprehension of graphical linguistics  

Science Conference Proceedings (OSTI)

In knowledge-work, there are increasing amounts of complex information rendered by information technology, which has led to the common term, information overload. Information visualization is one area where empirically tested semantic theory has not ... Keywords: cognitive load, decision support systems, graphical linguistics, human-computer interaction, medical informatics

Michael Workman

2007-11-01T23:59:59.000Z

470

Adaptive Load Forecasting Philip Anton de Saint-Aubain  

E-Print Network (OSTI)

mathematical models for the heat load. Based on district heating consumption data from four houses in a small taken is to reveal the details in the heating consumption in resi- dential houses by developing the heating signals into different components. One of the models is able to split the overall consumption

471

Long-term residential load forecasting. Final report  

SciTech Connect

The main objective of this study was to isolate and evaluate the importance of various factors, many of which are household characteristics and weather conditions, that determine the demand for electricity at different times of day. A second purpose was to investigate one of the factors in detail, namely, prices, which was feasible because half of the households in the sample were subjected to time-of-day pricing. Substantial differences between the load curves of the experimental and control groups were found. Households in the experimental group significantly decreased electricity usage when its price was high, the consumption being shifted partly into the early morning hours but more heavily into the evening. The importance of certain appliances in shifting the load curve is also clearly brought out. For example, households with a dishwasher or electric heating appeared to change the timing of use of these appliances under peak-load pricing. Other appliances were also important in determining the load curve for both groups. Swimming pool pumps and air conditioning, for instance, were important determinants in the summer, whereas in the winter, electric heating and dishwashers substantially increased consumption levels.

Granger, C.W.J.; Engle, R.F.; Ramanathan, R.; Andersen, A.

1978-02-01T23:59:59.000Z

472

Load-carrying capacity of oils for rolling mills  

SciTech Connect

This article reports on an investigation of the loadcarrying capacity of the compounded oils Pp-6, Pp-17, and Pp-28 that have been developed for liquid-friction bearings (LFB) as compared to nonadditive oils. A PZhT-140-300 single-roll stand for the lubrication of a regular-production PZhT-180 bearing was used in the study. The load/sliding speed curves obtained from the test oil were compared with the theoretical curve for the load-carrying capacity of the LFB for nonadditive oil and the curve obtained for the oil base stock at the corresponding viscosity level. It is determined that the compounded oils examined are 15-25% better in terms of load-carrying capacity than the oil base stocks, and 20-25% better than the nonadditive oils. The results demonstrate that the introduction of additives increases the load-carrying capacity of oils for LFBs in rolling mills by 20-25%, depending on viscosity.

Grigor' eva, N.I.; Badyshtova, K.M.; Ivankina, E.B.; Kolobov, N.I.; Toloka, V.I.

1984-07-01T23:59:59.000Z

473

Load beam unit replaceable inserts for dry coal extrusion pumps  

Science Conference Proceedings (OSTI)

A track assembly for a particulate material extrusion pump according to an exemplary aspect of the present disclosure includes a link assembly with a roller bearing. An insert mounted to a load beam located such that the roller bearing contacts the insert.

Saunders, Timothy; Brady, John D.

2012-11-13T23:59:59.000Z

474

Electric Load Prediction Using a Bilinear Recurrent Neural Network  

Science Conference Proceedings (OSTI)

A prediction scheme of electric load using a Bilinear Recurrent Neural Network (BRNN) is proposed in this paper. Since the BRNN is based on the bilinear polynomial, BRNN has been successfully used in modeling highly nonlinear systems with time-series ... Keywords: recurrent, neural network, forecasting, electricity

Jae-Young Kim; Dong-Chul Park; Dong-Min Woo

2010-03-01T23:59:59.000Z

475

On the operating unit size of load/store architectures†  

Science Conference Proceedings (OSTI)

We introduce a strict version of the concept of a load/store instruction set architecture in the setting of Maurer machines. We take the view that transformations on the states of a Maurer machine are achieved by applying threads as considered in thread ...

J. a. Bergstra; C. a. Middelburg

2010-06-01T23:59:59.000Z

476

Generalized solar load ratio correlation for direct gain buildings  

DOE Green Energy (OSTI)

A generalized solar load ratio correlation has been developed for direct gain buildings by generating relationships between the correlation parameters and two fundamental design parameters. The first design parameter is the steady state conductance of the solar aperture, U/sub c/. The second is the effective heat capacity of the solar zone, EHC.

Wray, W.O.; Best, E.D.

1986-01-01T23:59:59.000Z

477

Managing plug-loads for demand response within buildings  

Science Conference Proceedings (OSTI)

Detailed and accurate energy accounting is an important first step in improving energy efficiency within buildings. Based on this information, building managers can perform active energy management, especially during demand response situations that require ... Keywords: energy management, energy metering, plug-loads management, wireless sensor network

Thomas Weng; Bharathan Balaji; Seemanta Dutta; Rajesh Gupta; Yuvraj Agarwal

2011-11-01T23:59:59.000Z

478

Load Reduction, Demand Response and Energy Efficient Technologies and Strategies  

SciTech Connect

The Department of Energy’s (DOE’s) Pacific Northwest National Laboratory (PNNL) was tasked by the DOE Office of Electricity (OE) to recommend load reduction and grid integration strategies, and identify additional demand response (energy efficiency/conservation opportunities) and strategies at the Forest City Housing (FCH) redevelopment at Pearl Harbor and the Marine Corps Base Hawaii (MCBH) at Kaneohe Bay. The goal was to provide FCH staff a path forward to manage their electricity load and thus reduce costs at these FCH family housing developments. The initial focus of the work was at the MCBH given the MCBH has a demand-ratchet tariff, relatively high demand (~18 MW) and a commensurate high blended electricity rate (26 cents/kWh). The peak demand for MCBH occurs in July-August. And, on average, family housing at MCBH contributes ~36% to the MCBH total energy consumption. Thus, a significant load reduction in family housing can have a considerable impact on the overall site load. Based on a site visit to the MCBH and meetings with MCBH installation, FCH, and Hawaiian Electric Company (HECO) staff, recommended actions (including a "smart grid" recommendation) that can be undertaken by FCH to manage and reduce peak-demand in family housing are made. Recommendations are also made to reduce overall energy consumption, and thus reduce demand in FCH family housing.

Boyd, Paul A.; Parker, Graham B.; Hatley, Darrel D.

2008-11-19T23:59:59.000Z

479

Maximizing efficiency of solar-powered systems by load matching  

Science Conference Proceedings (OSTI)

Solar power is an important source of renewable energy for many low-power systems. Matching the power consumption level with the supply level can make a great difference in the efficiency of power utilization. This paper proposes a source-tracking power ... Keywords: load matching, photovoltaics, power management, power model, solar energy, solar-aware

Dexin Li; Pai H. Chou

2004-08-01T23:59:59.000Z

480

ORNL/TM-2007/060 Loads Providing Ancillary Services  

E-Print Network (OSTI)

appear in different zones at the same time and (b) hot water loads. 3.2. Technologies The newest engines have these characteristics. The costs for the discrete fuel cell11 technology are interpolated dominant technologies. Research shows that no fuel cell or micro turbine adoption takes place in our

Note: This page contains sample records for the topic "loading front loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Computational study of compressive loading of carbon nanotubes  

Science Conference Proceedings (OSTI)

A reduced-order general continuum method is used to examine the mechanical behavior of single-walled carbon nanotubes (CNTs) under compressive loading and unloading conditions. Quasi-static solutions are sought where the total energy of the system is ... Keywords: carbon nanotube, component, finite element method, mechanical properties

Yang Yang; William W. Liou

2010-03-01T23:59:59.000Z

482

A Dual Supply Buck Converter with Improved Light Load Efficiency  

E-Print Network (OSTI)

Power consumption is the primary concern in battery-operated portable applications. Buck converters have gained popularity in powering portable devices due to their compact size, good current delivery capability and high efficiency. However, portable devices are operating under light load condition for the most of the time. Conventional buck converters suffer from low light-load efficiency which severely limits battery lifetime. In this project, a novel technique for buck converter is proposed to reduce the switching loss by reducing the effective input supply voltage at light load. This is achieved by switching between two different input voltages (3.3V and 1.65V) depending on the output current value. Experimental results show that this technique improves the efficiency at light loads by 18.07%. The buck voltage possesses an output voltage of 0.9V and provides a maximum output current of 400mA. The buck converter operates at a switching frequency of 1MHz. The prototype was fabricated using 0.18µm CMOS technology, and occupies a total active area of 0.6039mm^2.

Chen, Hui

2013-05-01T23:59:59.000Z

483

The Load and Availability of Byzantine Quorum Systems  

Science Conference Proceedings (OSTI)

Replicated services accessed via quorums enable each access to be performed at only a subset (quorum) of the servers and achieve consistency across accesses by requiring any two quorums to intersect. Recently, b-masking quorum systems, ... Keywords: Byzantine failures, availability, distributed computing, load, quorum systems, replication

Dahlia Malkhi; Michael K. Reiter; Avishai Wool

2000-04-01T23:59:59.000Z

484

Combining daylighting, personal controls, and load shedding offers  

E-Print Network (OSTI)

systems can enhance occupant comfort and improve organizational productivity. However, even with advances lighting system to respond to available daylight and demand response control · Allows building occupantsCombining daylighting, personal controls, and load shedding offers enormous potential for reducing

485

Assessment of Industrial Load for Demand Response across Western Interconnect  

SciTech Connect

Demand response (DR) has the ability to both increase power grid reliability and potentially reduce operating system costs. Understanding the role of demand response in grid modeling has been difficult due to complex nature of the load characteristics compared to the modeled generation and the variation in load types. This is particularly true of industrial loads, where hundreds of different industries exist with varying availability for demand response. We present a framework considering industrial loads for the development of availability profiles that can provide more regional understanding and can be inserted into analysis software for further study. The developed framework utilizes a number of different informational resources, algorithms, and real-world measurements to perform a bottom-up approach in the development of a new database with representation of the potential demand response resource in the industrial sector across the U.S. This tool houses statistical values of energy and demand response (DR) potential by industrial plant and geospatially locates the information for aggregation for different territories without proprietary information. This report will discuss this framework and the analyzed quantities of demand response for Western Interconnect (WI) in support of evaluation of the cost production modeling with power grid modeling efforts of demand response.

Alkadi, Nasr E [ORNL] [ORNL; Starke, Michael R [ORNL] [ORNL; Ma, Ookie [United States Department of Energy (DOE), Office of Efficiency and Renewable Energy (EERE)] [United States Department of Energy (DOE), Office of Efficiency and Renewable Energy (EERE)

2013-11-01T23:59:59.000Z

486

Ursa: Scalable Load and Power Management in Cloud Storage Systems  

Science Conference Proceedings (OSTI)

Enterprise and cloud data centers are comprised of tens of thousands of servers providing petabytes of storage to a large number of users and applications. At such a scale, these storage systems face two key challenges: (1) hot-spots due to the dynamic ... Keywords: Load management, linear programming, optimization, power management, storage

Gae-Won You; Seung-Won Hwang; Navendu Jain

2013-03-01T23:59:59.000Z

487

Locality Aware Dynamic Load Management for Massively Multiplayer Games  

E-Print Network (OSTI)

hot-spot overload for server 6 and shedding to a remote server is the only option. The net effect with a dynamic load management algorithm enables us to better handle transient crowding by adaptively dispersing MMOG pat- terns, such as, player flocking. Flocking is the movement of many players to one area or hot

Amza, Cristiana

488

Estimated radiactive and shock loading of fusion reactor armor  

SciTech Connect

Inertial confinement fusion (ICF) is of interest as a source of neutrons for proliferation-resistant and high burn-up fission reactor designs. ICF is a transient process, each implosion leading to energy release over a short period, with a continuous series of ICF operations needed to drive the fission reactor. ICF yields energy in the form of MeV-range neutrons and ions, and thermal x-rays. These radiations, particularly the thermal x-rays, can deposit a pulse of energy in the wall of the ICF chamber, inducing loading by isochoric heating (i.e. at constant volume before the material can expand) or by ablation of material from the surface. The explosion of the hot ICF system, and the compression of any fill material in the chamber, may also result in direct mechanical loading by a blast wave (decaying shock) reaching the chamber wall. The chamber wall must be able to survive the repetitive loading events for long enough for the reactor to operate economically. It is thus necessary to understand the loading induced by ICF systems in possible chamber wall designs, and to predict the response and life time of the wall. Estimates are given for the loading induced in the wall armor of the fusion chamber caused by ablative thermal radiation from the fusion plasma and by the hydrodynamic shock. Taking a version of the LIFE design as an example, the ablation pressure was estimated to be {approx}0.6 GPa with an approximately exponential decay with time constant {approx}0.6 ns. Radiation hydrodynamics simulations suggested that ablation of the W armor should be negligible.

Swift, D C

2008-11-25T23:59:59.000Z