Powered by Deep Web Technologies
Note: This page contains sample records for the topic "load three-junction concentrator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Three-junction solar cell  

DOE Patents [OSTI]

A photovoltaic solar cell is formed in a monolithic semiconductor. The cell contains three junctions. In sequence from the light-entering face, the junctions have a high, a medium, and a low energy gap. The lower junctions are connected in series by one or more metallic members connecting the top of the lower junction through apertures to the bottom of the middle junction. The upper junction is connected in voltage opposition to the lower and middle junctions by second metallic electrodes deposited in holes 60 through the upper junction. The second electrodes are connected to an external terminal.

Ludowise, Michael J. (Cupertino, CA)

1986-01-01T23:59:59.000Z

2

Wind loading on solar concentrators: some general considerations  

SciTech Connect (OSTI)

A survey has been completed to examine the problems and complications arising from wind loading on solar concentrators. Wind loading is site specific and has an important bearing on the design, cost, performance, operation and maintenance, safety, survival, and replacement of solar collecting systems. Emphasis herein is on paraboloidal, two-axis tracking systems. Thermal receiver problems also are discussed. Wind characteristics are discussed from a general point of view; current methods for determining design wind speed are reviewed. Aerodynamic coefficients are defined and illustrative examples are presented. Wind tunnel testing is discussed, and environmental wind tunnels are reviewed; recent results on heliostat arrays are reviewed as well. Aeroelasticity in relation to structural design is discussed briefly. Wind loads, i.e., forces and moments, are proportional to the square of the mean wind velocity. Forces are proportional to the square of concentrator diameter, and moments are proportional to the cube of diameter. Thus, wind loads have an important bearing on size selection from both cost and performance standpoints. It is concluded that sufficient information exists so that reasonably accurate predictions of wind loading are possible for a given paraboloidal concentrator configuration, provided that reliable and relevant wind conditions are specified. Such predictions will be useful to the design engineer and to the systems engineer as well. Information is lacking, however, on wind effects in field arrays of paraboloidal concentrators. Wind tunnel tests have been performed on model heliostat arrays, but there are important aerodynamic differences between heliostats and paraboloidal dishes.

Roschke, E. J.

1984-05-01T23:59:59.000Z

3

San Francisco Estuary Institute Regional Watershed Program Concentrations and Loads of Mercury,  

E-Print Network [OSTI]

San Francisco Estuary Institute Regional Watershed Program Concentrations and Loads of Mercury #12;McKee, Leatherbarrow, and Oram, 2005 i CONCENTRATIONS AND LOADS OF MERCURY, PCBs, AND OC. Concentrations and loads of mercury, PCBs, and OC pesticides in the lower Guadalupe River, San Jose, California

4

Total Sediment Load from SEMEP Using Depth-Integrated Concentration Measurements  

E-Print Network [OSTI]

Total Sediment Load from SEMEP Using Depth-Integrated Concentration Measurements Seema C. Shah sediment load calculations on the basis of depth-integrated sediment concentration measurements for channels with significant sediment transport in suspension. The series expansion of the modified Einstein

Julien, Pierre Y.

5

A photoelastic stress analysis of a flat circular plate simply supported and subjected to a concentrated load at the center  

E-Print Network [OSTI]

LIBRARy 4 4 III coI I BGv IIf Tf4 A PHOTOELASTIC STRESS ANALYSIS OF A FLAT CIRCULAR PLATE SIWPLY SUPPORTED AND SUBJECTED TO A CONCENTRATED LOAD AT THE CENTERS A Thesis By Joseph Lloyd Fulbright Submitted to the Graduate School... AND SUBJECTED TO A CONCENTRATED LOAD AT THE CENTER, A Thesis By Joseph Lloyd Fulbright Approved as to Style and Content by& Chairman of Committee Head of Department May 1/58 ACKNOWLEDGEMENT The technical assistance and advice of Professor B. E...

Fulbright, Joseph Lloyd

1958-01-01T23:59:59.000Z

6

The design, fabrication and maintenance of semi-trailers employed in the highway transport of weight-concentrated radioactive loads  

SciTech Connect (OSTI)

Transportation of weight-concentrated radioactive loads by truck is an essential part of a safe and economical nuclear industry. This proposed standard presents guidance and performance criteria for the safe transport of these weight-concentrated radioactive loads. ANSI N14.30 will detail specific requirements for the design, fabrication, testing, in-service inspections, maintenance and certification of the semi-trailers to be employed in said service. Furthermore, guidelines for a quality assurance program are also enumerated. This standard would apply to any semi-trailer that may or may not be specifically designed to carry weight-concentrated loads. Equipment not suitable per the criteria established in the standard would be removed from service. The nature of the nuclear industry and the need for a positive public perception of the various processes and players, mandates that the highway transportation of weight-concentrated radioactive loads be standardized and made inherently safe. This proposed standard takes a giant step in that direction.

Huffman, D.S. [Allied-Signal Inc., Metropolis, IL (United States)

1991-12-31T23:59:59.000Z

7

A photoelastic investigation of the bending moment on a gear tooth due to a concentrated load  

E-Print Network [OSTI]

parallel to the X-Y plane was proportional to the stress CI on the X surface, or that ness, Mx, times the thickness of a slice, b, so that 12 Then M = M ~ b, or M M x ' x b 13 xmax 6M x h But since h = 1 in, for all models used in this research... AND LOADING . Material Mold . Casting Loading IV. ANALYSIS OF DATA r2 Orientation of Coordinate System. . . . . . . Determination of the Bending Moment, Mx, along the Fixed Edge Normal Stresses-Shear Difference Method . 12 12 l8 V. DISCUSSION...

Sun, Pu-Ning

1960-01-01T23:59:59.000Z

8

Evaluation Of Glass Density To Support The Estimation Of Fissile Mass Loadings From Iron Concentrations In SB8 Glasses  

SciTech Connect (OSTI)

The Department of Energy – Savannah River (DOE-SR) has provided direction to Savannah River Remediation (SRR) to maintain fissile concentration in glass below 897 g/m{sup 3}. In support of that guidance, the Savannah River National Laboratory (SRNL) provided a technical basis and a supporting Microsoft® Excel® spreadsheet for the evaluation of fissile loading in Sludge Batch 5 (SB5), Sludge Batch 6 (SB6), Sludge Batch 7a (SB7a), and Sludge Batch 7b (SB7b) glass based on the iron (Fe) concentration in glass as determined by the measurements from the Slurry Mix Evaporator (SME) acceptability analysis. SRR has since requested that the necessary density information be provided to allow SRR to update the Excel® spreadsheet so that it may be used to maintain fissile concentration in glass below 897 g/m{sup 3} during the processing of Sludge Batch 8 (SB8). One of the primary inputs into the fissile loading spreadsheet includes an upper bound for the density of SB8-based glasses. Thus, these bounding density values are to be used to assess the fissile concentration in this glass system. It should be noted that no changes are needed to the underlying structure of the Excel-based spreadsheet to support fissile assessments for SB8. However, SRR should update the other key inputs to the spreadsheet that are based on fissile and Fe concentrations reported from the SB8 Waste Acceptance Product Specification (WAPS) sample.

Edwards, T. B.; Peeler, D. K.; Kot, W. K.; Gan, H.; Pegg, I. L.

2013-04-30T23:59:59.000Z

9

INTERNATIONAL STUDIES OF ENHANCED WASTE LOADING AND IMPROVED MELT RATE FOR HIGH ALUMINA CONCENTRATION NUCLEAR WASTE GLASSES  

SciTech Connect (OSTI)

The goal of this study was to determine the impacts of glass compositions with high aluminum concentrations on melter performance, crystallization and chemical durability for Savannah River Site (SRS) and Hanford waste streams. Glass compositions for Hanford targeted both high aluminum concentrations in waste sludge and a high waste loading in the glass. Compositions for SRS targeted Sludge Batch 5, the next sludge batch to be processed in the Defense Waste Processing Facility (DWPF), which also has a relatively high aluminum concentration. Three frits were selected for combination with the SRS waste to evaluate their impact on melt rate. The glasses were melted in two small-scale test melters at the V. G. Khlopin Radium Institute. The results showed varying degrees of spinel formation in each of the glasses. Some improvements in melt rate were made by tailoring the frit composition for the SRS feeds. All of the Hanford and SRS compositions had acceptable chemical durability.

Fox, K; David Peeler, D; James Marra, J

2008-09-11T23:59:59.000Z

10

Modified vector control algorithm for increasing partial-load efficiency of fractional-slot concentrated-winding surface PM machines  

SciTech Connect (OSTI)

This paper presents a modified vector control algorithm for a fractional-slot concentrated-winding surface permanent magnet (SPM) machine that has been developed to maximize the machine's partial-load efficiency over a wide range of operating conditions. By increasing the amplitude of the negative d-axis current, the resulting increase in the stator copper losses can be more than offset by the reduction in the iron core losses achieved by lowering the stator d-axis flux amplitude. The effectiveness of this technique has been demonstrated using both analytical models and finite element analysis for a 55-kW (peak) SPM machine design developed for a demanding set of traction drive performance requirements. For this example, the modified control strategy increases the partial-load efficiency at 20% of rated torque by > 6% at 2000 r/min compared to the maximum torque/ampere algorithm, making the machine much more attractive for its intended application.

El-Refaie, Ayman M [ORNL; Jahns, Thomas M [ORNL; Reddy, Patel [University of Wisconsin; McKeever, John W [ORNL

2008-01-01T23:59:59.000Z

11

A photoelastic study of simply supported rectangular beams with holes on the vertical center lines and subjected to concentrated loads  

E-Print Network [OSTI]

Page 1 Stress Concentration Factors for Various Points for the Beams of this Study . 33 LIST OF FIGURES Figure Page Dimensions of the Models Model in the Loading Frame Fringe Pattern of Beam 1. Isoclinics for Beam L-1 Isoclinics for Beam S-1 10... Calibration of Model for Beam 1 Sketch of a Beam Showing: (a) Locations of sections under consideration (b) dX, b Y, he, S, S, and the sign convention for r xy Horizontal and Vertical Stresses for Beam 1 13 22 Horizontal and Vertical Stresses for Beam...

Lin, Ping Hua

1965-01-01T23:59:59.000Z

12

The photoelastic determination of the principal stresses in polygons having round central holes and subjected to a concentrated diagonal compressive load  

E-Print Network [OSTI]

THE PHOTOELASTIC DETERMINATION OF THE PRINCIPAL STRESSES IN POLYGONS HAVING ROUND CENTRAL HOLES AND SUMECTED TO A CONCENTRATED DIAGONAL COMPRESSIVE LOAD A Thesis TOMMY GLYNN PRIDDX Submitted to the Graduate Sohool of the Agrioultural...

Priddy, Tommy Glynn

1961-01-01T23:59:59.000Z

13

Final Report on Control Algorithm to Improve the Partial-Load Efficiency of Surface PM Machines with Fractional-Slot Concentrated Windings  

SciTech Connect (OSTI)

Surface permanent magnet (SPM) synchronous machines using fractional-slot concentrated windings are being investigated as candidates for high-performance traction machines for automotive electric propulsion systems. It has been shown analytically and experimentally that such designs can achieve very wide constant-power speed ratios (CPSR) [1,2]. This work has shown that machines of this type are capable of achieving very low cogging torque amplitudes as well as significantly increasing the machine power density [3-5] compared to SPM machines using conventional distributed windings. High efficiency can be achieved in this class of SPM machine by making special efforts to suppress the eddy-current losses in the magnets [6-8], accompanied by efforts to minimize the iron losses in the rotor and stator cores. Considerable attention has traditionally been devoted to maximizing the full-load efficiency of traction machines at their rated operating points and along their maximum-power vs. speed envelopes for higher speeds [9,10]. For example, on-line control approaches have been presented for maximizing the full-load efficiency of PM synchronous machines, including the use of negative d-axis stator current to reduce the core losses [11,12]. However, another important performance specification for electric traction applications is the machine's efficiency at partial loads. Partial-load efficiency is particularly important if the target traction application requires long periods of cruising operation at light loads that are significantly lower than the maximum drive capabilities. While the design of the machine itself is clearly important, investigation has shown that this is a case where the choice of the control algorithm plays a critical role in determining the maximum partial-load efficiency that the machine actually achieves in the traction drive system. There is no evidence that this important topic has been addressed for this type of SPM machine by any other authors. This topic takes on even greater significance for fractional-slot concentrated-winding SPM machine designs. In particular, maximizing the torque/power density of this class of SPM machines typically leads to machine designs with high numbers of poles. The resulting high electrical frequencies can easily result in high stator core losses unless special care is taken during the machine design process. The purpose of this report is to discuss a modified vector control algorithm for a fractional-slot concentrated winding SPM machine that has been developed to maximize the machine's partial-load efficiency over a wide range of operating conditions. For purposes of this discussion, a 55 kW (peak) SPM machine designed to meet requirements established in the US FreedomCar program [13] is used as the basis for demonstrating the proposed technique. A combination of closed-form analysis [14] and finite element analysis (FEA) is used during this investigation.

McKeever, John W [ORNL; Reddy, Patel [University of Wisconsin; Jahns, Thomas M [ORNL

2007-05-01T23:59:59.000Z

14

FINAL REPORT ON CONTROL ALGORITHM TO IMPROVE THE PARTIAL-LOAD EFFICIENCY OFSURFACE PM MACHINES WITH FRACTIONAL-SLOT CONCENTRATED WINDINGS  

SciTech Connect (OSTI)

Surface permanent magnet (SPM) synchronous machines using fractional-slot concentrated windings are being investigated as candidates for high-performance traction machines for automotive electric propulsion systems. It has been shown analytically and experimentally that such designs can achieve very wide constant-power speed ratios (CPSR) [1,2]. This work has shown that machines of this type are capable of achieving very low cogging torque amplitudes as well as significantly increasing the machine power density [3-5] compared to SPM machines using conventional distributed windings. High efficiency can be achieved in this class of SPM machine by making special efforts to suppress the eddy-current losses in the magnets [6-8], accompanied by efforts to minimize the iron losses in the rotor and stator cores. Considerable attention has traditionally been devoted to maximizing the full-load efficiency of traction machines at their rated operating points and along their maximum-power vs. speed envelopes for higher speeds [9,10]. For example, on-line control approaches have been presented for maximizing the full-load efficiency of PM synchronous machines, including the use of negative d-axis stator current to reduce the core losses [11,12]. However, another important performance specification for electric traction applications is the machine's efficiency at partial loads. Partial-load efficiency is particularly important if the target traction application requires long periods of cruising operation at light loads that are significantly lower than the maximum drive capabilities. While the design of the machine itself is clearly important, investigation has shown that this is a case where the choice of the control algorithm plays a critical role in determining the maximum partial-load efficiency that the machine actually achieves in the traction drive system. There is no evidence that this important topic has been addressed for this type of SPM machine by any other authors. This topic takes on even greater significance for fractional-slot concentrated-winding SPM machine designs. In particular, maximizing the torque/power density of this class of SPM machines typically leads to machine designs with high numbers of poles. The resulting high electrical frequencies can easily result in high stator core losses unless special care is taken during the machine design process. The purpose of this report is to discuss a modified vector control algorithm for a fractional-slot concentrated winding SPM machine that has been developed to maximize the machine's partial-load efficiency over a wide range of operating conditions. For purposes of this discussion, a 55 kW (peak) SPM machine designed to meet requirements established in the US FreedomCar program [13] is used as the basis for demonstrating the proposed technique. A combination of closed-form analysis [14] and finite element analysis (FEA) is used during this investigation.

Reddy, P.B.; Jahns, T.M.

2007-04-30T23:59:59.000Z

15

A study of the dynamic response of a homogeneous, isotropic, semi-infinite, two-layered half-space to a concentrated vertical load on the free surface varying harmonically with time  

E-Print Network [OSTI]

A STUDY OF THE DYNAMJC RESPONSE OF A HOMOGENEOUS, ZSOTROPIC, SEMI-INFZNITE, TWO-LAYERED HALF-SPACE TO A CONCENTRATED VERTICAL LOAD ON THE FREE SURFACE VARYING HARMONICALLY WITH TIME A Thesis By PAUL RAY CORDER Submitted to the Graduate...-LAYERED HALF-SPACE TO A CONCENTRATED VERTICAL LOAD ON THE FREE SURFACE VARYING HARMONICALLY WITH TIME A Thesis By PAUL RAY CORDER Approved as to style and content by: (Chairman of Co. . ittee ) (Head of Department) (" ember) ~c +- January 1965...

Corder, Paul Ray

1965-01-01T23:59:59.000Z

16

Flow Duration Curve Load Duration Curve  

E-Print Network [OSTI]

#12;Flow Duration Curve Load Duration Curve #12;1. Develop Flow Duration Curve 2. Estimate load given flow and concentration data--select appropriate conversion factors 3. Develop Load Duration Curve 4. Plot observed data with Load Duration Curve #12;What are they? How do you make one? #12;Describes

17

Flow Duration Curve Load Duration Curve  

E-Print Network [OSTI]

Flow Duration Curve Load Duration Curve 1. Develop Flow Duration Curve 2. Estimate load given flow and concentration data--select appropriate conversion factors 3. Develop Load Duration Curve 4. Plot observed data with Load Duration Curve What are they? How do you make one? Describes the percent of time a flow rate

18

Plug Load  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the1 - September 2006Photovoltaic Theory andVelocityPlatinum-LoadingPlug-Load Sign In

19

Load Management for Industry  

E-Print Network [OSTI]

In the electric utility industry, load management provides the opportunity to control customer loads to beneficially alter a utility's load curve Load management alternatives are covered. Load management methods can be broadly classified into four...

Konsevick, W. J., Jr.

1982-01-01T23:59:59.000Z

20

Wind load reduction for heliostats  

SciTech Connect (OSTI)

This report presents the results of wind-tunnel tests supported through the Solar Energy Research Institute (SERI) by the Office of Solar Thermal Technology of the US Department of Energy as part of the SERI research effort on innovative concentrators. As gravity loads on drive mechanisms are reduced through stretched-membrane technology, the wind-load contribution of the required drive capacity increases in percentage. Reduction of wind loads can provide economy in support structure and heliostat drive. Wind-tunnel tests have been directed at finding methods to reduce wind loads on heliostats. The tests investigated primarily the mean forces, moments, and the possibility of measuring fluctuating forces in anticipation of reducing those forces. A significant increase in ability to predict heliostat wind loads and their reduction within a heliostat field was achieved.

Peterka, J.A.; Hosoya, N.; Bienkiewicz, B.; Cermak, J.E.

1986-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "load three-junction concentrator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Scattering Solar Thermal Concentrators  

Broader source: Energy.gov [DOE]

"This fact sheet describes a scattering solar thermal concentrators project awarded under the DOE's 2012 SunShot Concentrating Solar Power R&D award program. The team, led by the Pennsylvania State University, is working to demonstrate a new, scattering-based approach to concentrating sunlight that aims to improve the overall performance and reliability of the collector field. The research team aims to show that scattering solar thermal collectors are capable of achieving optical performance equal to state-of-the-art parabolic trough systems, but with the added benefits of immunity to wind-load tracking error, more efficient land use, and utilization of stationary receivers."

22

Concentrating collectors  

SciTech Connect (OSTI)

Selected specifications from sixteen concentrating collector manufacturers are tabulated. Eleven are linear parabolic trough collectors, and the others include slats, cylindrical trough, linear Fresnel lens, parabolic cylindrical Fresnel lens, and two point focus parabolic dish collectors. Also included is a brief discussion of the operating temperatures and other design considerations for concentrating collectors. (LEW)

Not Available

1981-06-01T23:59:59.000Z

23

Load sensing system  

DOE Patents [OSTI]

A load sensing system inexpensively monitors the weight and temperature of stored nuclear material for long periods of time in widely variable environments. The system can include an electrostatic load cell that encodes weight and temperature into a digital signal which is sent to a remote monitor via a coaxial cable. The same cable is used to supply the load cell with power. When multiple load cells are used, vast

Sohns, Carl W. (Oak Ridge, TN); Nodine, Robert N. (Knoxville, TN); Wallace, Steven Allen (Knoxville, TN)

1999-01-01T23:59:59.000Z

24

Loading margin Stable operating  

E-Print Network [OSTI]

Linear approximation at p1 Actual loading margin Loadingmargin Parameter p p1 p2 p3 IEEE Transactions collapse. Linear and quadratic estimates to the variation of the loading margin with respect to any sys power support, wheeling, load model param- eters, line susceptance, and generator dispatch. The accuracy

25

Load regulating expansion fixture  

DOE Patents [OSTI]

A free standing self contained device for bonding ultra thin metallic films, such as 0.001 inch beryllium foils is disclosed. The device will regulate to a predetermined load for solid state bonding when heated to a bonding temperature. The device includes a load regulating feature, whereby the expansion stresses generated for bonding are regulated and self adjusting. The load regulator comprises a pair of friction isolators with a plurality of annealed copper members located therebetween. The device, with the load regulator, will adjust to and maintain a stress level needed to successfully and economically complete a leak tight bond without damaging thin foils or other delicate components. 1 fig.

Wagner, L.M.; Strum, M.J.

1998-12-15T23:59:59.000Z

26

Load regulating expansion fixture  

DOE Patents [OSTI]

A free standing self contained device for bonding ultra thin metallic films, such as 0.001 inch beryllium foils. The device will regulate to a predetermined load for solid state bonding when heated to a bonding temperature. The device includes a load regulating feature, whereby the expansion stresses generated for bonding are regulated and self adjusting. The load regulator comprises a pair of friction isolators with a plurality of annealed copper members located therebetween. The device, with the load regulator, will adjust to and maintain a stress level needed to successfully and economically complete a leak tight bond without damaging thin foils or other delicate components.

Wagner, Lawrence M. (San Jose, CA); Strum, Michael J. (San Jose, CA)

1998-01-01T23:59:59.000Z

27

Load sensing system  

DOE Patents [OSTI]

A load sensing system inexpensively monitors the weight and temperature of stored nuclear material for long periods of time in widely variable environments. The system can include an electrostatic load cell that encodes weight and temperature into a digital signal which is sent to a remote monitor via a coaxial cable. The same cable is used to supply the load cell with power. When multiple load cells are used, vast inventories of stored nuclear material can be continuously monitored and inventoried of minimal cost. 4 figs.

Sohns, C.W.; Nodine, R.N.; Wallace, S.A.

1999-05-04T23:59:59.000Z

28

16 Load Data Cleansing and Bus Load  

E-Print Network [OSTI]

-to-day operations, system analysis in smart grids, system visualization, system performance reliability, energy..............................................................................................................397 #12;376 Smart Grids The load forecast generally provides annual peak values for the whole system saving, and accuracy in system planning [1­4]. * This work is partly supported by a collaborative

Wang, Ke

29

contingency Nominal loading margin  

E-Print Network [OSTI]

is estimated. First a nose curve is computed by continuation to obtain a nominal loading margin. Then linear and the very fast computation of the linear estimates. Keywords: Power system security, contingency analy- sis formulas derived in [4]. The computations are summarized: 1 A pattern of load increase, generator dispatch

30

Scalable Load Distribution and Load Balancing for Dynamic Parallel Programs  

E-Print Network [OSTI]

shown that the algorithm scales according to the definition of scalability given following. LoadScalable Load Distribution and Load Balancing for Dynamic Parallel Programs E. Berger and J. C of an integrated load distribution-load balancing algorithm which was targeted to be both efficient and scalable

Berger, Emery

31

Load research manual. Volume 3. Load research for advanced technologies  

SciTech Connect (OSTI)

This three-volume manual presents technical guidelines for electric utility load research. Special attention is given to issues raised by the load data reporting requirements of the Public Utility Regulatory Policies Act of 1978 and to problems faced by smaller utilities that are initiating load research programs. The manual includes guides to load research literature and glossaries of load research and statistical terms. In Volume 3, special load research procedures are presented for solar, wind, and cogeneration technologies.

None

1980-11-01T23:59:59.000Z

32

Load Monitoring CEC/LMTF Load Research Program  

SciTech Connect (OSTI)

This white paper addresses the needs, options, current practices of load monitoring. Recommendations on load monitoring applications and future directions are also presented.

Huang, Zhenyu; Lesieutre, B.; Yang, Steve; Ellis, A.; Meklin, A.; Wong, B.; Gaikwad, A.; Brooks, D.; Hammerstrom, Donald J.; Phillips, John; Kosterev, Dmitry; Hoffman, M.; Ciniglio, O.; Hartwell, R.; Pourbeik, P.; Maitra, A.; Lu, Ning

2007-11-30T23:59:59.000Z

33

Composite Load Model Evaluation  

SciTech Connect (OSTI)

The WECC load modeling task force has dedicated its effort in the past few years to develop a composite load model that can represent behaviors of different end-user components. The modeling structure of the composite load model is recommended by the WECC load modeling task force. GE Energy has implemented this composite load model with a new function CMPLDW in its power system simulation software package, PSLF. For the last several years, Bonneville Power Administration (BPA) has taken the lead and collaborated with GE Energy to develop the new composite load model. Pacific Northwest National Laboratory (PNNL) and BPA joint force and conducted the evaluation of the CMPLDW and test its parameter settings to make sure that: • the model initializes properly, • all the parameter settings are functioning, and • the simulation results are as expected. The PNNL effort focused on testing the CMPLDW in a 4-bus system. An exhaustive testing on each parameter setting has been performed to guarantee each setting works. This report is a summary of the PNNL testing results and conclusions.

Lu, Ning; Qiao, Hong (Amy)

2007-09-30T23:59:59.000Z

34

Mean and peak wind load reduction on heliostats  

SciTech Connect (OSTI)

This report presents the results of wind-tunnel tests supported through the Solar Energy Research Institute (SERI) by the Office of Solar Thermal Technology of the US Department of Energy as part of the SERI research effort on innovative concentrators. As gravity loads on drive mechanisms are reduced through stretched-membrane technology, the wind-load contribution of the required drive capacity increases in percentage. Reduction of wind loads can provide economy in support structure and heliostat drive. Wind-tunnel tests have been directed at finding methods to reduce wind loads on heliostats. The tests investigated both mean and peak forces, and moments. A significant increase in ability to predict heliostat wind loads and their reduction within a heliostat field was achieved. In addition, a preliminary review of wind loads on parabolic dish collectors was conducted, resulting in a recommended research program for these type collectors. 42 refs., 38 figs., 1 tab.

Peterka, J.A.; Tan, L.; Bienkiewcz, B.; Cermak, J.E.

1987-09-01T23:59:59.000Z

35

Load Management Made Simple  

E-Print Network [OSTI]

Company have moved to a demand side or load management mode which seeks to influence customers to change electric usage patterns to more efficiently use available generating capacity. Since 1970, the TUEC system peak demand has more than doubled from about...

Schneider, K.

1985-01-01T23:59:59.000Z

36

Cooling load estimation methods  

SciTech Connect (OSTI)

Ongoing research on quantifying the cooling loads in residential buildings, particularly buildings with passive solar heating systems, is described. Correlations are described that permit auxiliary cooling estimates from monthly average insolation and weather data. The objective of the research is to develop a simple analysis method, useful early in design, to estimate the annual cooling energy required of a given building.

McFarland, R.D.

1984-01-01T23:59:59.000Z

37

Batch load anaerobic digestion of dairy manure  

E-Print Network [OSTI]

and resource recovery. Anaerobic digestion of manure has re- ceived much attention as a method to reduce the pollution threat to the environment while reclaiming energy in the form of methane gas from the biomass. Currently there is one commercial anaerobic... production than the conventional process used in most studies to date. The objective of this research was to evaluate a batch load digestion process for methane production from dairy manure to determine the optimum influent total solids concentration...

Egg, Richard P

1979-01-01T23:59:59.000Z

38

Load Management: Opportunity or Calamity?  

E-Print Network [OSTI]

larger now than prior to 1973. Utilities are examining two options which can be termed load management. One option is to control discretionary loads during peak periods. Cycling of residential water heaters or shutting off industrial electric furnaces...

Males, R.; Hassig, N.

1981-01-01T23:59:59.000Z

39

Concentrating Solar Power Forum Concentrating Photovoltaics (Presentation)  

SciTech Connect (OSTI)

This presentation's summaries: a convenient truth, comparison of three concentrator technologies, value of high efficiency, and status of industry.

Kurtz, S.

2008-05-06T23:59:59.000Z

40

Online Load Balancing for Related Machines  

E-Print Network [OSTI]

of entire schedule s as follows: load(s; i) = 1 v i X s(j)=i p j ; Load(s) = max i load(s; i) It is easyOn­line Load Balancing for Related Machines Piotr Berman \\Lambda Moses Charikar y Marek Karpinski z­line load balancing was studied extensively over the years (cf., e.g., [7], [3], [4], and [2

Karpinski, Marek

Note: This page contains sample records for the topic "load three-junction concentrator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH  

E-Print Network [OSTI]

components such as power sources, loads,  transformers and components such as power sources, loads,  transformers and 

Lesieutre, Bernard

2013-01-01T23:59:59.000Z

42

Dynamic load balancing of applications  

DOE Patents [OSTI]

An application-level method for dynamically maintaining global load balance on a parallel computer, particularly on massively parallel MIMD computers. Global load balancing is achieved by overlapping neighborhoods of processors, where each neighborhood performs local load balancing. The method supports a large class of finite element and finite difference based applications and provides an automatic element management system to which applications are easily integrated.

Wheat, Stephen R. (Albuquerque, NM)

1997-01-01T23:59:59.000Z

43

Demand Response: Load Management Programs  

E-Print Network [OSTI]

CenterPoint Load Management Programs CATEE Conference October, 2012 Agenda Outline I. General Demand Response Definition II. General Demand Response Program Rules III. CenterPoint Commercial Program IV. CenterPoint Residential Programs... V. Residential Discussion Points Demand Response Definition of load management per energy efficiency rule 25.181: ? Load control activities that result in a reduction in peak demand, or a shifting of energy usage from a peak to an off...

Simon, J.

2012-01-01T23:59:59.000Z

44

Dynamic load balancing of applications  

DOE Patents [OSTI]

An application-level method for dynamically maintaining global load balance on a parallel computer, particularly on massively parallel MIMD computers is disclosed. Global load balancing is achieved by overlapping neighborhoods of processors, where each neighborhood performs local load balancing. The method supports a large class of finite element and finite difference based applications and provides an automatic element management system to which applications are easily integrated. 13 figs.

Wheat, S.R.

1997-05-13T23:59:59.000Z

45

High-Power Rf Load  

DOE Patents [OSTI]

A compact high-power RF load comprises a series of very low Q resonators, or chokes [16], in a circular waveguide [10]. The sequence of chokes absorb the RF power gradually in a short distance while keeping the bandwidth relatively wide. A polarizer [12] at the input end of the load is provided to convert incoming TE.sub.10 mode signals to circularly polarized TE.sub.11 mode signals. Because the load operates in the circularly polarized mode, the energy is uniformly and efficiently absorbed and the load is more compact than a rectangular load. Using these techniques, a load having a bandwidth of 500 MHz can be produced with an average power dissipation level of 1.5 kW at X-band, and a peak power dissipation of 100 MW. The load can be made from common lossy materials, such as stainless steel, and is less than 15 cm in length. These techniques can also produce loads for use as an alternative to ordinary waveguide loads in small and medium RF accelerators, in radar systems, and in other microwave applications. The design is easily scalable to other RF frequencies and adaptable to the use of other lossy materials.

Tantawi, Sami G. (San Mateo, CA); Vlieks, Arnold E. (Livermore, CA)

1998-09-01T23:59:59.000Z

46

Concentrated Solar Thermoelectric Power  

Broader source: Energy.gov (indexed) [DOE]

CONCENTRATING SOLAR POWER PROGRAM REVIEW 2013 Concentrated Solar Thermoelectric Power Principal Investigator: Prof. Gang Chen Massachusetts Institute of Technology Cambridge, MA...

47

Concentrating Photovoltaics (Presentation)  

SciTech Connect (OSTI)

Solar is growing rapidly, and the concentrating photovoltaics industry-both high- and low-concentration cell approaches-may be ready to ramp production in 2009.

Kurtz, S.

2009-01-20T23:59:59.000Z

48

Spring loaded locator pin assembly  

DOE Patents [OSTI]

This invention deals with spring loaded locator pins. Locator pins are sometimes referred to as captured pins. This is a mechanism which locks two items together with the pin that is spring loaded so that it drops into a locator hole on the work piece.

Groll, Todd A. (Idaho Falls, ID); White, James P. (Pocatelo, ID)

1998-01-01T23:59:59.000Z

49

Spring loaded locator pin assembly  

DOE Patents [OSTI]

This invention deals with spring loaded locator pins. Locator pins are sometimes referred to as captured pins. This is a mechanism which locks two items together with the pin that is spring loaded so that it drops into a locator hole on the work piece. 5 figs.

Groll, T.A.; White, J.P.

1998-03-03T23:59:59.000Z

50

Load Forecasting of Supermarket Refrigeration  

E-Print Network [OSTI]

energy system. Observed refrigeration load and local ambient temperature from a Danish su- permarket renewable energy, is increasing, therefore a flexible energy system is needed. In the present ThesisLoad Forecasting of Supermarket Refrigeration Lisa Buth Rasmussen Kongens Lyngby 2013 M.Sc.-2013

51

ORIGINAL PAPER Post-processing of concentrated fermented milk: influence  

E-Print Network [OSTI]

ORIGINAL PAPER Post-processing of concentrated fermented milk: influence of temperature and holding of particle clusters in concentrated, fermented milk (protein content 8.2% (w/w)) during post temperature load, thus, rapid cooling reduces the Dairy Sci. & Technol. (2012) 92:91­107 DOI 10.1007/s13594

Paris-Sud XI, Université de

52

Electrical and Production Load Factors  

E-Print Network [OSTI]

, Texas Abstract Load factors and operating hours of small and medium-sized industrial plants are analyzed to classify shift-work patterns and develop energy conservation diagnostic tools. This paper discusses two types of electric load factors... for each shift classification within major industry groups. The load factor based on billing hours (ELF) increases with operating hours from about 0.4 for a nominal one shift operation, to about 0.7 for around-the-clock operation. On the other hand...

Sen, T.; Heffington, W. M.

53

Gas concentration cells for utilizing energy  

DOE Patents [OSTI]

An apparatus and method are disclosed for utilizing energy, in which the apparatus may be used for generating electricity or as a heat pump. When used as an electrical generator, two gas concentration cells are connected in a closed gas circuit. The first gas concentration cell is heated and generates electricity. The second gas concentration cell repressurizes the gas which travels between the cells. The electrical energy which is generated by the first cell drives the second cell as well as an electrical load. When used as a heat pump, two gas concentration cells are connected in a closed gas circuit. The first cell is supplied with electrical energy from a direct current source and releases heat. The second cell absorbs heat. The apparatus has no moving parts and thus approximates a heat engine. 4 figs.

Salomon, R.E.

1987-06-30T23:59:59.000Z

54

Gas concentration cells for utilizing energy  

DOE Patents [OSTI]

An apparatus and method for utilizing energy, in which the apparatus may be used for generating electricity or as a heat pump. When used as an electrical generator, two gas concentration cells are connected in a closed gas circuit. The first gas concentration cell is heated and generates electricity. The second gas concentration cell repressurizes the gas which travels between the cells. The electrical energy which is generated by the first cell drives the second cell as well as an electrical load. When used as a heat pump, two gas concentration cells are connected in a closed gas circuit. The first cell is supplied with electrical energy from a direct current source and releases heat. The second cell absorbs heat. The apparatus has no moving parts and thus approximates a heat engine.

Salomon, Robert E. (Philadelphia, PA)

1987-01-01T23:59:59.000Z

55

Concentrating Solar Power  

SciTech Connect (OSTI)

Summarizes the goals and activities of the DOE Solar Energy Technologies Program efforts within its concentrating solar power subprogram.

Not Available

2008-09-01T23:59:59.000Z

56

Sandia Wind Turbine Loads Database  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

The Sandia Wind Turbine Loads Database is divided into six files, each corresponding to approximately 16 years of simulation. The files are text files with data in columnar format. The 424MB zipped file containing six data files can be downloaded by the public. The files simulate 10-minute maximum loads for the NREL 5MW wind turbine. The details of the loads simulations can be found in the paper: “Decades of Wind Turbine Loads Simulations”, M. Barone, J. Paquette, B. Resor, and L. Manuel, AIAA2012-1288 (3.69MB PDF). Note that the site-average wind speed is 10 m/s (class I-B), not the 8.5 m/s reported in the paper.

57

Building load control and optimization  

E-Print Network [OSTI]

Researchers and practitioners have proposed a variety of solutions to reduce electricity consumption and curtail peak demand. This research focuses on load control by improving the operations in existing building HVAC ...

Xing, Hai-Yun Helen, 1976-

2004-01-01T23:59:59.000Z

58

Photovoltaic concentrator initiative: Concentrator cell development  

SciTech Connect (OSTI)

This project involves the development of a large-area, low-cost, high-efficiency concentrator solar cell for use in the Entech 22-sun linear-focus Fresnel lens concentrator system. The buried contact solar cell developed at the University of New South Wales was selected for this project. Both Entech and the University of New South Wales are subcontractors. This annual report presents the program efforts from November 1990 through December 1991, including the design of the cell, development of a baseline cell process, and presentation of the results of preliminary cell processing. Important results include a cell designed for operation in a real concentrator system and substitution of mechanical grooving for the previously utilized laser scribing.

Wohlgemuth, J.H.; Narayanan, S. [Solarex Corp., Frederick, MD (US)

1993-05-01T23:59:59.000Z

59

Cooling load design tool for UFAD systems.  

E-Print Network [OSTI]

Underfloor Air Distribution (UFAD) Design Guide. Atlanta:Load Design Tool for Underfloor Air Distribution Systems. ”for design cooling loads in underfloor air distribution (

Bauman, Fred; Schiavon, Stefano; Webster, Tom; Lee, Kwang Ho

2010-01-01T23:59:59.000Z

60

Self-aligning biaxial load frame  

DOE Patents [OSTI]

An self-aligning biaxial loading apparatus for use in testing the strength of specimens while maintaining a constant specimen centroid during the loading operation. The self-aligning biaxial loading apparatus consists of a load frame and two load assemblies for imparting two independent perpendicular forces upon a test specimen. The constant test specimen centroid is maintained by providing elements for linear motion of the load frame relative to a fixed crosshead, and by alignment and linear motion elements of one load assembly relative to the load frame.

Ward, Michael B. (Idaho Falls, ID); Epstein, Jonathan S. (Idaho Falls, ID); Lloyd, W. Randolph (Idaho Falls, ID)

1994-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "load three-junction concentrator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Self-aligning biaxial load frame  

DOE Patents [OSTI]

An self-aligning biaxial loading apparatus for use in testing the strength of specimens while maintaining a constant specimen centroid during the loading operation. The self-aligning biaxial loading apparatus consists of a load frame and two load assemblies for imparting two independent perpendicular forces upon a test specimen. The constant test specimen centroid is maintained by providing elements for linear motion of the load frame relative to a fixed cross head, and by alignment and linear motion elements of one load assembly relative to the load frame. 3 figures.

Ward, M.B.; Epstein, J.S.; Lloyd, W.R.

1994-01-18T23:59:59.000Z

62

Influence of loading rate on axially loaded piles in clay  

E-Print Network [OSTI]

. Coyle (Member) ave u ofs (Member) . Hsrsc (Head of Department) May 1984 ABSTRACT Influence of Loading Rate on Axially Loaded Piles in Clay. (May 1984) Enrique Eduardo Garland Ponce, B. S. , Texas A8M University Chairman of Committee: Dr. Jean... and support during all phases of this study. The author also wishes to acknowledge Drs. Harry M. Coyle and David Dubofski who served as members of the advisory committee. Special notes of gratitude to Dr . Wayne A. Dunlap for his aid in the design...

Garland Ponce, Enrique Eduardo

1984-01-01T23:59:59.000Z

63

{Control of Residential Load Management Networks Using Real Time Pricing  

E-Print Network [OSTI]

loads to deliver load following and regulation, withproducts like load following and spinning reserve.following of constant power references. Chapter 7 Implications of Load

Burke, William Jerome

2010-01-01T23:59:59.000Z

64

Concentrated Solar Thermoelectric Power  

Broader source: Energy.gov [DOE]

This presentation was delivered at the SunShot Concentrating Solar Power (CSP) Program Review 2013, held April 23–25, 2013 near Phoenix, Arizona.

65

Scattering Solar Thermal Concentrators  

Broader source: Energy.gov (indexed) [DOE]

is a rendering of a scattering solar concentrator. Light collected by a cylindrical Fresnel lens is focused within a curved glass "guide" sheet, where it is redirected into...

66

Concentrated Solar Power Generation.  

E-Print Network [OSTI]

??Solar power generation is the most promising technology to transfer energy consumption reliance from fossil fuel to renewable sources. Concentrated solar power generation is a… (more)

Jin, Zhilei

2013-01-01T23:59:59.000Z

67

Piezoelectric film load cell robot collision detector  

DOE Patents [OSTI]

A piezoelectric load cell which can be utilized for detecting collisions and obstruction of a robot arm end effector includes a force sensing element of metallized polyvinylidene fluoride (PVDF) film. The piezoelectric film sensing element and a resilient support pad are clamped in compression between upper and lower plates. The lower plate has a central recess in its upper face for supporting the support pad and sensing element, while the upper plate has a corresponding central projection formed on its lower face for bearing on the sensing element and support pad. The upper and lower plates are doweled together for concentric alignment and screwed together. The upper and lower plates are also adapted for mounting between the robot arm wrist and end effector. 3 figs.

Lembke, J.R.

1989-04-18T23:59:59.000Z

68

Piezoelectric film load cell robot collision detector  

DOE Patents [OSTI]

A piezoelectric load cell which can be utilized for detecting collisions and obstruction of a robot arm end effector includes a force sensing element of metallized polyvinylidene fluoride (PVDF) film. The piezoelectric film sensing element and a resilient support pad are clamped in compression between upper and lower plates. The lower plate has a central recess in its upper face for supporting the support pad and sensing element, while the upper plate has a corresponding central projection formed on its lower face for bearing on the sensing element and support pad. The upper and lower plates are dowelled together for concentric alignment and screwed together. The upper and lower plates are also adapted for mounting between the robot arm wrist and end effector. 3 figs.

Lembke, J.R.

1988-03-15T23:59:59.000Z

69

Piezoelectric film load cell robot collision detector  

DOE Patents [OSTI]

A piezoelectric load cell which can be utilized for detecting collisions and obstruction of a robot arm end effector includes a force sensing element of metallized polyvinylidene fluoride (PVDF) film. The piezoelectric film sensing element and a resilient support pad are clamped in compression between upper and lower plates. The lower plate has a central recess in its upper face for supporting the support pad and sensing element, while the upper plate has a corresponding central projection formed on its lower face for bearing on the sensing element and support pad. The upper and lower plates are dowelled together for concentric alignment and screwed together. The upper and lower plates are also adapted for mounting between the robot arm wrist and end effector.

Lembke, John R. (Overland Park, KS)

1989-04-18T23:59:59.000Z

70

MODELING AND CONTROL OF THERMOSTATICALLY CONTROLLED LOADS  

E-Print Network [OSTI]

controlled loads (TCLs) has demonstrated that such load following is feasible, but analyt- ical models) is well matched to the role of load following. Re- search into the behavior of TCLs began with the work was then employed in a minimum variance control law to demonstrate the load following capability of a population

Hiskens, Ian A.

71

Concentration in Green Design  

E-Print Network [OSTI]

, energy, infrastructure or transport. Participants in this specialization area work closely with the GreenConcentration in Green Design Research and Education Opportunities Carnegie Mellon University Civil and Environmental Engineering www.ce.cmu.edu M.S. Concentration Green Design - Course Only Track As an extension

Shewchuk, Jonathan

72

Concentrating photovoltaic solar panel  

DOE Patents [OSTI]

The present invention relates to photovoltaic power systems, photovoltaic concentrator modules, and related methods. In particular, the present invention features concentrator modules having interior points of attachment for an articulating mechanism and/or an articulating mechanism that has a unique arrangement of chassis members so as to isolate bending, etc. from being transferred among the chassis members. The present invention also features adjustable solar panel mounting features and/or mounting features with two or more degrees of freedom. The present invention also features a mechanical fastener for secondary optics in a concentrator module.

Cashion, Steven A; Bowser, Michael R; Farrelly, Mark B; Hines, Braden E; Holmes, Howard C; Johnson, Jr., Richard L; Russell, Richard J; Turk, Michael F

2014-04-15T23:59:59.000Z

73

Design and Analysis of a High-Efficiency, Cost-Effective Solar Concentrator John H. Reif  

E-Print Network [OSTI]

that concentrate solar energy for conversion into usable energy. Ideally, a solar concentrating system should have, wind and sand loading, and abrasion. Many arid and desert areas, best suited for solar energy advantages of our solar concentrating system: are low cost and durability. Unlike most prior solar

Reif, John H.

74

Online Load Balancing for Related Machines 1 Piotr Berman  

E-Print Network [OSTI]

), the load of a machine i in schedule s and Load(s), the load of entire schedule s as follows: load(s; i) = 1On­line Load Balancing for Related Machines 1 Piotr Berman The Pennsylvania State University of randomized algorithms for this problem. Key Words: on­line algorithm, load balancing, related machines

Charikar, Moses

75

Organic photovoltaics and concentrators  

E-Print Network [OSTI]

The separation of light harvesting and charge generation offers several advantages in the design of organic photovoltaics and organic solar concentrators for the ultimate end goal of achieving a lower cost solar electric ...

Mapel, Jonathan King

2008-01-01T23:59:59.000Z

76

Water Sample Concentrator  

ScienceCinema (OSTI)

Automated portable device that concentrates and packages a sample of suspected contaminated water for safe, efficient transport to a qualified analytical laboratory. This technology will help safeguard against pathogen contamination or chemical and biolog

Idaho National Laboratory

2010-01-08T23:59:59.000Z

77

Concentrator silicon cell research  

SciTech Connect (OSTI)

This project continued the developments of high-efficiency silicon concentrator solar cells with the goal of achieving a cell efficiency in the 26 to 27 percent range at a concentration level of 150 suns of greater. The target efficiency was achieved with the new PERL (passivated emitter, rear locally diffused) cell structure, but only at low concentration levels around 20 suns. The PERL structure combines oxide passivation of both top and rear surfaces of the cells with small area contact to heavily doped regions on the top and rear surfaces. Efficiency in the 22 to 23 percent range was also demonstrated for large-area concentrator cells fabricated with the buried contact solar cell processing sequence, either when combined with prismatic covers or with other innovative approaches to reduce top contact shadowing. 19 refs.

Green, M.A.; Wenham, S.R.; Zhang, F.; Zhao, J.; Wang, A. [New South Wales Univ., Kensington (Australia). Solar Photovoltaic Lab.

1992-04-01T23:59:59.000Z

78

Joined concentric tubes  

DOE Patents [OSTI]

Tubular objects having two or more concentric layers that have different properties are joined to one another during their manufacture primarily by compressive and friction forces generated by shrinkage during sintering and possibly mechanical interlocking. It is not necessary for the concentric tubes to display adhesive-, chemical- or sinter-bonding to each other in order to achieve a strong bond. This facilitates joining of dissimilar materials, such as ceramics and metals.

DeJonghe, Lutgard; Jacobson, Craig; Tucker, Michael; Visco, Steven

2013-01-01T23:59:59.000Z

79

Independent review of estimated load reductions for PJM's small customer load response pilot project  

E-Print Network [OSTI]

of Estimated Load Reductions for PJM’s Small Customer Loadof Estimated Load Reductions for PJM’s Small Customer LoadResponse Pilot Project Prepared for PJM Interconnection, LLC

Heffner, G.; Moezzi, M.; Goldman, C.

2004-01-01T23:59:59.000Z

80

Spinning Reserve From Responsive Loads  

SciTech Connect (OSTI)

Responsive load is the most underutilized reliability resource available to the power system today. It is currently not used at all to provide spinning reserve. Historically there were good reasons for this, but recent technological advances in communications and controls have provided new capabilities and eliminated many of the old obstacles. North American Electric Reliability Council (NERC), Federal Energy Regulatory Commission (FERC), Northeast Power Coordinating Council (NPCC), New York State Reliability Council (NYSRC), and New York Independent System Operator (NYISO) rules are beginning to recognize these changes and are starting to encourage responsive load provision of reliability services. The Carrier ComfortChoice responsive thermostats provide an example of these technological advances. This is a technology aimed at reducing summer peak demand through central control of residential and small commercial air-conditioning loads. It is being utilized by Long Island Power Authority (LIPA), Consolidated Edison (ConEd), Southern California Edison (SCE), and San Diego Gas and Electric (SDG&E). The technology is capable of delivering even greater response in the faster spinning reserve time frame (while still providing peak reduction). Analysis of demand reduction testing results from LIPA during the summer of 2002 provides evidence to back up this claim. It also demonstrates that loads are different from generators and that the conventional wisdom, which advocates for starting with large loads as better ancillary service providers, is flawed. The tempting approach of incrementally adapting ancillary service requirements, which were established when generators were the only available resources, will not work. While it is easier for most generators to provide replacement power and non-spinning reserve (the slower response services) than it is to supply spinning reserve (the fastest service), the opposite is true for many loads. Also, there is more financial reward for supplying spinning reserve than for supplying the other reserve services as a result of the higher spinning reserve prices. The LIPAedge program (LIPA's demand reduction program using Carrier ComfortChoice thermostats) provides an opportunity to test the use of responsive load for spinning reserve. With potentially 75 MW of spinning reserve capability already installed, this test program can also make an important contribution to the capacity needs of Long Island during the summer of 2003. Testing could also be done at ConEd ({approx}30 MW), SCE ({approx}15 MW), and/or SDG&E ({approx}15 MW). This paper is divided into six chapters. Chapter 2 discusses the contingency reserve ancillary services, their functions in supporting power system reliability, and their technical requirements. It also discusses the policy and tariff requirements and attempts to distinguish between ones that are genuinely necessary and ones that are artifacts of the technologies that were historically used to provide the services. Chapter 3 discusses how responsive load could provide contingency reserves (especially spinning reserve) for the power system. Chapter 4 specifically discusses the Carrier ComfortChoice responsive thermostat technology, the LIPAedge experience with that technology, and how the technology could be used to supply spinning reserve. Chapter 5 discusses a number of unresolved issues and suggests areas for further research. Chapter 6 offers conclusions and recommendations.

Kirby, B.J.

2003-04-08T23:59:59.000Z

Note: This page contains sample records for the topic "load three-junction concentrator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

PASSIVE DETECTION OF VEHICLE LOADING  

SciTech Connect (OSTI)

The Digital Imaging and Remote Sensing Laboratory (DIRS) at the Rochester Institute of Technology, along with the Savannah River National Laboratory is investigating passive methods to quantify vehicle loading. The research described in this paper investigates multiple vehicle indicators including brake temperature, tire temperature, engine temperature, acceleration and deceleration rates, engine acoustics, suspension response, tire deformation and vibrational response. Our investigation into these variables includes building and implementing a sensing system for data collection as well as multiple full-scale vehicle tests. The sensing system includes; infrared video cameras, triaxial accelerometers, microphones, video cameras and thermocouples. The full scale testing includes both a medium size dump truck and a tractor-trailer truck on closed courses with loads spanning the full range of the vehicle's capacity. Statistical analysis of the collected data is used to determine the effectiveness of each of the indicators for characterizing the weight of a vehicle. The final sensing system will monitor multiple load indicators and combine the results to achieve a more accurate measurement than any of the indicators could provide alone.

Garrett, A.

2012-01-03T23:59:59.000Z

82

Photovoltaic solar concentrator  

DOE Patents [OSTI]

A photovoltaic solar concentrator is disclosed with one or more transverse-junction solar cells (also termed point contact solar cells) and a lens located above each solar cell to concentrate sunlight onto the solar cell to generate electricity. Piezoelectric actuators tilt or translate each lens to track the sun using a feedback-control circuit which senses the electricity generated by one or more of the solar cells. The piezoelectric actuators can be coupled through a displacement-multiplier linkage to provide an increased range of movement of each lens. Each lens in the solar concentrator can be supported on a frame (also termed a tilt plate) having three legs, with the movement of the legs being controlled by the piezoelectric actuators.

Nielson, Gregory N.; Okandan, Murat; Resnick, Paul J.; Cruz-Campa, Jose Luis

2012-12-11T23:59:59.000Z

83

Airborne agent concentration analysis  

DOE Patents [OSTI]

A method and system for inferring airborne contaminant concentrations in rooms without contaminant sensors, based on data collected by contaminant sensors in other rooms of a building, using known airflow interconnectivity data. The method solves a least squares problem that minimizes the difference between measured and predicted contaminant sensor concentrations with respect to an unknown contaminant release time. Solutions are constrained to providing non-negative initial contaminant concentrations in all rooms. The method can be used to identify a near-optimal distribution of sensors within the building, when then number of available sensors is less than the total number of rooms. This is achieved by having a system-sensor matrix that is non-singular, and by selecting that distribution which yields the lowest condition number of all the distributions considered. The method can predict one or more contaminant initial release points from the collected data.

Gelbard, Fred

2004-02-03T23:59:59.000Z

84

Residential Load Management Program and Pilot  

E-Print Network [OSTI]

In 1986 LCRA embarked on residential load management to control peak summer loads. At that time, LCRA was considered a summer peaking utility, and residential air conditioning and water heating systems were selected for control. The program...

Haverlah, D.; Riordon, K.

1994-01-01T23:59:59.000Z

85

Helicase Loading at Chromosomal Origins of Replication  

E-Print Network [OSTI]

Loading of the replicative DNA helicase at origins of replication is of central importance in DNA replication. As the first of the replication fork proteins assemble at chromosomal origins of replication, the loaded helicase ...

Bell, Stephen P.

86

Communication Load Reduction for Neural Network Implementations  

E-Print Network [OSTI]

the total amount of communication load, followed by a placement of partitions onto proces- sors 3]. We

Behnke, Sven

87

Plug Load Behavioral Change Demonstration Project  

SciTech Connect (OSTI)

This report documents the methods and results of a plug load study of the Environmental Protection Agency's Region 8 Headquarters in Denver, Colorado, conducted by the National Renewable Energy Laboratory. The study quantified the effect of mechanical and behavioral change approaches on plug load energy reduction and identified effective ways to reduce plug load energy. Load reduction approaches included automated energy management systems and behavioral change strategies.

Metzger, I.; Kandt, A.; VanGeet, O.

2011-08-01T23:59:59.000Z

88

Analysis Methodology for Industrial Load Profiles  

E-Print Network [OSTI]

ANALYSIS METHODOLOGY FOR INDUSTRIAL LOAD PROFILES Thomas W. Reddoch Executive Vice President Eleclrolek Concepts, Inc. Knoxvillc, Tennessee ABSTRACT A methodology is provided for evaluating the impact of various demand-side management... (OSM) options on industrial customers. The basic approach uses customer metered load profile data as a basis for the customer load shape. OSM technologies are represented as load shapes and are used as a basis for altering the customers existing...

Reddoch, T. W.

89

A Novel Approach to Determining Motor Load  

E-Print Network [OSTI]

A NOVEL APPROACH TO DETERMINING MOTOR LOAD by Michael Brown Georgia Tech Research Institute Atlanta, Georgia ABSTRACf Properly sized electric motors are essential if industrial plant efficiency is to be optimized and energy costs... minimized. Because of the difficully in making power measurements on three phase motors, loading is rarely, if ever, checked. A simple indication of motor load can be achieved by measuring operating speed because speed and load are almost linearly...

Brown, M.

90

Investigation of sands subjected to dynamic loading  

E-Print Network [OSTI]

become apparent that dynamic, or sud- denly applied loads, present a different type of problem to the engineer. Wind loads on tall structures, pile driving, nuclear blasts, and many other familiar loading conditions cannot be de- scribed or handled... an earthquake or nuclear blast. Also under this category of loading is the pulse which would be purposely induced to fail the soil structure for the purpose of excavation or pile driving. As part of a broader research project concerned with pile dri- ving...

Reeves, Gary Neil

1967-01-01T23:59:59.000Z

91

System and method employing a minimum distance and a load feature database to identify electric load types of different electric loads  

DOE Patents [OSTI]

A method identifies electric load types of a plurality of different electric loads. The method includes providing a load feature database of a plurality of different electric load types, each of the different electric load types including a first load feature vector having at least four different load features; sensing a voltage signal and a current signal for each of the different electric loads; determining a second load feature vector comprising at least four different load features from the sensed voltage signal and the sensed current signal for a corresponding one of the different electric loads; and identifying by a processor one of the different electric load types by determining a minimum distance of the second load feature vector to the first load feature vector of the different electric load types of the load feature database.

Lu, Bin; Yang, Yi; Sharma, Santosh K; Zambare, Prachi; Madane, Mayura A

2014-12-23T23:59:59.000Z

92

Properly Evaluating load-following products  

SciTech Connect (OSTI)

The authors briefly survey the jurisdictions where load-following products have been successfully used, examine the characteristics of the load-following products, and explain the shortcomings and inaccurate conclusions of previous analyses. A more thorough analysis reveals that the load-following products fulfill the public policy objectives for which they have been designed and do not adversely impact wholesale electricity markets.

Cavicchi, Joseph; Lemon, Andrew

2009-01-15T23:59:59.000Z

93

1993 Pacific Northwest Loads and Resources Study.  

SciTech Connect (OSTI)

The Loads and Resources Study is presented in three documents: (1) this summary of Federal system and Pacific Northwest region loads and resources; (2) a technical appendix detailing forecasted Pacific Northwest economic trends and loads, and (3) a technical appendix detailing the loads and resources for each major Pacific Northwest generating utility. In this loads and resources study, resource availability is compared with a range of forecasted electricity consumption. The forecasted future electricity demands -- firm loads -- are subtracted from the projected capability of existing and {open_quotes}contracted for{close_quotes} resources to determine whether Bonneville Power Administration (BPA) and the region will be surplus or deficit. If resources are greater than loads in any particular year or month, there is a surplus of energy and/or capacity, which BPA can sell to increase revenues. Conversely, if firm loads exceed available resources, there is a deficit of energy and/or capacity, and additional conservation, contract purchases, or generating resources will be needed to meet load growth. The Pacific Northwest Loads and Resources Study analyzes the Pacific Northwest`s projected loads and available generating resources in two parts: (1) the loads and resources of the Federal system, for which BPA is the marketing agency; and (2) the larger Pacific Northwest regional power system, which includes loads and resource in addition to the Federal system. The loads and resources analysis in this study simulates the operation of the power system under the Pacific Northwest Coordination Agreement (PNCA) produced by the Pacific Northwest Coordinating Group. This study presents the Federal system and regional analyses for five load forecasts: high, medium-high, medium, medium-low, and low. This analysis projects the yearly average energy consumption and resource availability for Operating Years (OY) 1994--95 through 2003--04.

United States. Bonneville Power Administration.

1993-12-01T23:59:59.000Z

94

High loading uranium fuel plate  

DOE Patents [OSTI]

Two embodiments of a high uranium fuel plate are disclosed which contain a meat comprising structured uranium compound confined between a pair of diffusion bonded ductile metal cladding plates uniformly covering the meat, the meat having a uniform high fuel loading comprising a content of uranium compound greater than about 45 Vol. % at a porosity not greater than about 10 Vol. %. In a first embodiment, the meat is a plurality of parallel wires of uranium compound. In a second embodiment, the meat is a dispersion compact containing uranium compound. The fuel plates are fabricated by a hot isostatic pressing process.

Wiencek, Thomas C. (Bolingbrook, IL); Domagala, Robert F. (Indian Head Park, IL); Thresh, Henry R. (Palos Heights, IL)

1990-01-01T23:59:59.000Z

95

Automated fuel pin loading system  

DOE Patents [OSTI]

An automated loading system for nuclear reactor fuel elements utilizes a gravity feed conveyor which permits individual fuel pins to roll along a constrained path perpendicular to their respective lengths. The individual lengths of fuel cladding are directed onto movable transports, where they are aligned coaxially with the axes of associated handling equipment at appropriate production stations. Each fuel pin can be reciprocated axially and/or rotated about its axis as required during handling steps. The fuel pins are inserted as a batch prior to welding of end caps by one of two disclosed welding systems.

Christiansen, David W. (Kennewick, WA); Brown, William F. (West Richland, WA); Steffen, Jim M. (Richland, WA)

1985-01-01T23:59:59.000Z

96

Dynamic Load Balancing of Virtualized Database Services Using Hints and Load  

E-Print Network [OSTI]

server during runtime. Figure 1 shows the load curve of a typical interactive service. In the morningDynamic Load Balancing of Virtualized Database Services Using Hints and Load Forecasting Daniel-organizing infrastructures to react proactively. For this pur- pose we present two techniques: Short-term load forecasting

Kemper, Alfons

97

High payload six-axis load sensor  

DOE Patents [OSTI]

A repairable high-payload six-axis load sensor includes a table, a base, and at least three shear-pin load transducers removably mounted between the table and the base. Removable mounting permits easy replacement of damaged shear pins. Preferably, the shear-pin load transducers are responsive to shear forces imparted along the two axes perpendicular to an axis of minimum sensitivity characteristic of the transducer. Responsive to an applied shear force, each shear-pin load transducer can produce an electrical signal proportional to the reaction force. The load sensor can further include a structure for receiving the proportional electrical signals and computing the applied load corresponding to the proportional electrical signals. The computed load can be expressed in terms of a three-dimensional XYZ Cartesian coordinate system.

Jansen, John F. (Knoxville, TN); Lind, Randall F. (Knoxville, TN)

2003-01-01T23:59:59.000Z

98

Low reflectance radio frequency load  

DOE Patents [OSTI]

A load for traveling microwave energy has an absorptive volume defined by cylindrical body enclosed by a first end cap and a second end cap. The first end cap has an aperture for the passage of an input waveguide with a rotating part that is coupled to a reflective mirror. The inner surfaces of the absorptive volume consist of a resistive material or are coated with a coating which absorbs a fraction of incident RF energy, and the remainder of the RF energy reflects. The angle of the reflector and end caps is selected such that reflected RF energy dissipates an increasing percentage of the remaining RF energy at each reflection, and the reflected RF energy which returns to the rotating mirror is directed to the back surface of the rotating reflector, and is not coupled to the input waveguide. Additionally, the reflector may have a surface which generates a more uniform power distribution function axially and laterally, to increase the power handling capability of the RF load. The input waveguide may be corrugated for HE11 mode input energy.

Ives, R. Lawrence; Mizuhara, Yosuke M

2014-04-01T23:59:59.000Z

99

CONTENTS Concentrated Gas Hydrate  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth7-1D: Vegetation Proposed New Substation Sites Proposed Route BTRICGEGR-N Goods PO 1 of 81,Concentrated Gas

100

Bulk Modulus Capacitor Load Cells  

SciTech Connect (OSTI)

Measurement of forces present at various locations within the SSC Model Dipole collared coil assembly is of great practical interest to development engineers. Of particular interest are the forces between coils at the parting plane and forces that exist between coils and pole pieces. It is also desired to observe these forces under the various conditions that a magnet will experience such as: during the collaring process, post-collaring, under the influence of cryogens, and during field excitation. A twenty eight thousandths of an inch thick capacitor load cell which utilizes the hydrostatic condition of a stressed plastic dielectric has been designed. These cells are currently being installed on SSC Model Dipoles. The theory, development, and application of these cells will be discussed.

Dickey, C.E.

1990-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "load three-junction concentrator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

High voltage load resistor array  

DOE Patents [OSTI]

A high voltage resistor comprising an array of a plurality of parallel electrically connected resistor elements each containing a resistive solution, attached at each end thereof to an end plate, and about the circumference of each of the end plates, a corona reduction ring. Each of the resistor elements comprises an insulating tube having an electrode inserted into each end thereof and held in position by one or more hose clamps about the outer periphery of the insulating tube. According to a preferred embodiment, the electrode is fabricated from stainless steel and has a mushroom shape at one end, that inserted into the tube, and a flat end for engagement with the end plates that provides connection of the resistor array and with a load.

Lehmann, Monty Ray (Smithfield, VA)

2005-01-18T23:59:59.000Z

102

Loads Providing Ancillary Services: Review of International Experience  

E-Print Network [OSTI]

In PJM for example, loads and generators that can follow theto generators and loads, who can follow operator’s second bya reflection of the load’s inability to follow minute-by-

Heffner, Grayson

2008-01-01T23:59:59.000Z

103

Preliminary Evaluation of Load Management for Electricity End Users  

E-Print Network [OSTI]

The planning, design and implementation of load management is complex and expensive. The results of a load management program are subject to numerous uncertainties related to load characteristics, power cost savings, load management costs...

Collier, S. E.

1984-01-01T23:59:59.000Z

104

Optical oxygen concentration monitor  

DOE Patents [OSTI]

A system for measuring and monitoring the concentration of oxygen uses as a light source an argon discharge lamp, which inherently emits light with a spectral line that is close to one of oxygen's A-band absorption lines. In a preferred embodiment, the argon line is split into sets of components of shorter and longer wavelengths by a magnetic field of approximately 2000 Gauss that is parallel to the light propagation from the lamp. The longer wavelength components are centered on an absorption line of oxygen and thus readily absorbed, and the shorter wavelength components are moved away from that line and minimally absorbed. A polarization modulator alternately selects the set of the longer wavelength, or upshifted, components or the set of the shorter wavelength, or downshifted, components and passes the selected set to an environment of interest. After transmission over a path through that environment, the transmitted optical flux of the argon line varies as a result of the differential absorption. The system then determines the concentration of oxygen in the environment based on the changes in the transmitted optical flux between the two sets of components. In alternative embodiments modulation is achieved by selectively reversing the polarity of the magnetic field or by selectively supplying the magnetic field to either the emitting plasma of the lamp or the environment of interest.

Kebabian, Paul (Acton, MA)

1997-01-01T23:59:59.000Z

105

Online Load Balancing for Related Machines 1 (Revised Piotr Berman  

E-Print Network [OSTI]

s as follows: load(s; i) = 1 v i X s(j)=i p j ; Load(s) = max i load(s; i) It is easy to observe that findingOn­line Load Balancing for Related Machines 1 (Revised Version) Piotr Berman The Pennsylvania State of randomized algorithms for this problem. Key Words: on­line algorithm, load balancing, related machines

Karpinski, Marek

106

Loads Providing Ancillary Services: Review of International Experience  

E-Print Network [OSTI]

Load Following)Imbalance Management (Load Following) Energy Imbalanceload participation in ancillary service markets, we offer the following

Heffner, Grayson

2008-01-01T23:59:59.000Z

107

Loads Providing Ancillary Services: Review of International Experience  

E-Print Network [OSTI]

for generators. A partial list of load attributes andpartial list includes: • Minimum run times • Minimum off times • Minimum load

Heffner, Grayson

2008-01-01T23:59:59.000Z

108

FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH  

E-Print Network [OSTI]

Air Conditioner Testing in WECC,” IEEE Power  Engineering Air Conditioner Modeling, WECC Load Modeling Task  Force in power system studies: WECC progress update,? Power and 

Lesieutre, Bernard

2013-01-01T23:59:59.000Z

109

FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH  

E-Print Network [OSTI]

Lights HVAC Figure 15 Demand Response and Market AnalysisHVAC Load % of Total Hour of Day Figure 16 Demand Response and Market

Lesieutre, Bernard

2013-01-01T23:59:59.000Z

110

Decentralized customerlevel under frequency load shedding in...  

Open Energy Info (EERE)

project focuses on a smart demand side management of household consumers. Modern communication technology enables the management of large groups of distributed loads under a...

111

System and method employing a self-organizing map load feature database to identify electric load types of different electric loads  

SciTech Connect (OSTI)

A method identifies electric load types of a plurality of different electric loads. The method includes providing a self-organizing map load feature database of a plurality of different electric load types and a plurality of neurons, each of the load types corresponding to a number of the neurons; employing a weight vector for each of the neurons; sensing a voltage signal and a current signal for each of the loads; determining a load feature vector including at least four different load features from the sensed voltage signal and the sensed current signal for a corresponding one of the loads; and identifying by a processor one of the load types by relating the load feature vector to the neurons of the database by identifying the weight vector of one of the neurons corresponding to the one of the load types that is a minimal distance to the load feature vector.

Lu, Bin; Harley, Ronald G.; Du, Liang; Yang, Yi; Sharma, Santosh K.; Zambare, Prachi; Madane, Mayura A.

2014-06-17T23:59:59.000Z

112

Direct perturbation analysis on cables with concentrated loads P. Yu *, K. Pan  

E-Print Network [OSTI]

cables, overhead transmission lines, etc. The study of vibrations of suspended cables is of great is the galloping of overhead transmission lines which may cause severe disruptions in the electrical supply and even a cas- cading collapse of a lineĂ?s supporting towers. * Corresponding author. Tel.: +1

Yu, Pei

113

Distribution of stresses in a tapered cantilever beam due to a concentrated load at the end  

E-Print Network [OSTI]

212 228 246 248 233 233 207 202 233 271 272 0 840 15. 0 34o 1170 78. o 1089 312 58 TABM XVI 15 BKW SWAM BB THE~DHZTICAL ~BI TS y tuehes Elemeabary Beam Thecey os elk 'Cjy Psi Psi Psz Theoxy of Zlasiisi4y ~u Og Psi Psi Psi m. 840...

Wilhoit, James Cammack

1951-01-01T23:59:59.000Z

114

Buckling analysis of singly curved shallow bi-layered arch under concentrated loading  

E-Print Network [OSTI]

viable alternative to conventional sandwich materials in applications where the functional requirements can be met without the second face sheet of the sandwich. For structural applications bi-layered materials are required to have oil canning...

Sonawane, Mahesh

2009-05-15T23:59:59.000Z

115

Wind loading on solar collectors  

SciTech Connect (OSTI)

The present design methodology for the determination of wind loading on the various solar collectors has been reviewed and assessed. The total force coefficients of flat plates of aspect ratios 1.0 and 3.0, respectively, at various angles of attack obtained by using the guidelines of the ANSI A58.1-1982, have been compared with those obtained by using the methodology of the ASCE Task Committee, 1961, and the experimental results of the full-scale test of heliostats by Peglow. The turbulent energy spectra, currently employed in the building code, are compared with those of Kaimal et al., Lumley, and Ponofsky for wind velocities of 20.0 m/s and 40.24 m/s at an elevation of 9.15 m. The longitudinal spectra of the building code overestimates the Kaimal spectra in the frequency range of 0.007 Hz to 0.08 Hz and underestimates beyond the frequency of 0.08 Hz. The peak angles of attack, on the heliostat, stowed in horizontal position, due to turbulent vertical and lateral components of wind velocity, have been estimated by using Daniel's methodology for three wind velocities and compared with the value suggested by the code. The experimental results of a simple test in the laboratory indicate the feasibility of decreasing the drag forces of the flat plate by reducing the solidity ratio.

Bhaduri, S.; Murphy, L.M.

1985-06-01T23:59:59.000Z

116

Pressurized fluidized-bed combustion part-load behavior. Volume I. Summary report  

SciTech Connect (OSTI)

Tests performed during 1980 to determine the part-load characteristics of a pressurized fluidized-bed combustor for a combined-cycle power plant and to examine its behavior during load changing are discussed. Part-load operation was achieved by varying the bed temperature by amounts between 200 to 300/sup 0/F and the bed depth from between 9 and 10 ft at rates varying between 0.2 ft/min and 0.5 ft/min. The performance at part-load steady-state conditions and during transient conditions is reported with information on combustion efficiency (99% at full-load with 9 ft bed depth and 1650/sup 0/F bed temperature; 95% with 4 ft depth and 1390/sup 0/F); sulfur retention (95/sup 0/ at full load to 80% at low bed depth and low bed temperature); sulfur emissions (no definitive results); NO/sub x/ emissions (tendency for increase as bed temperature was reduced); alkali emissions (no bed temperature effect detected); and heat transfer. It was demonstrated that load can be altered in a rapid and controlled manner by changing combinations of bed depth temperature and pressure. The most important practical change was the reduction in O/sub 2/ concentration which occurred when the bed height was increased at a rapid rate. The extra energy required to reheat the incoming bed material resulted (in the most extreme case) in a temporary drop in excess air from 65% to 12%. In a full-scale plant the loss of heat from the stored bed material would be much lower and the excess air trough when increasing load would not be as pronounced. Nevertheless, it seems prudent to design full-scale plant for a full load excess air of not less than about 50% when using bed depth as a load control parameter.

Roberts, A. G.; Pillai, K. K.; Raven, P.; Wood, P.

1981-09-01T23:59:59.000Z

117

Effects of dynamic conditions and sheave efficiency on hook load, derrick load, and line tension  

E-Print Network [OSTI]

EFFECTS OF DYNAMIC CONDITIONS AND SHEAVE EFFICIENCY ON HOOK LOAD, DERRICK LOAD, AND LINE TENSION A Thesis by GREGORY ROBERT LUKE Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements... for the degree of MASTER OF SCIENCE May 1991 Major Subject: Petroleum Engineering EFFECTS OF DYNAMIC CONDITIONS AND SHEAVE EFFICIENCY ON HOOK LOAD, DERRICK LOAD, AND LINE TENSION A Thesis by GREGORY ROBERT LUKE Approved as to style and content by: Hans...

Luke, Gregory Robert

1991-01-01T23:59:59.000Z

118

Neurocontrol of Pressurized Water Reactors in Load-Follow Operations  

SciTech Connect (OSTI)

The neurocontrol technique was applied to control a pressurized water reactor (PWR) in load-follow operations. Generalized learning or direct inverse control architecture was adopted in which the neural network was trained off-line to learn the inverse model of the PWR. Two neural network controllers were designed: One provided control rod position, which controlled the axial power distribution, and the other provided the change in boron concentration, which adjusted core total power. An additional feedback controller was designed so that power tracking capability was improved. The time duration between control actions was 15 min; thus, the xenon effect is limited and can be neglected. Therefore, the xenon concentration was not considered as a controller input variable, which simplified controller design. Center target strategy and minimum boron strategy were used to operate the reactor, and the simulation results demonstrated the effectiveness and performance of the proposed controller.

Lin Chaung; Shen Chihming

2000-12-15T23:59:59.000Z

119

REACTIVE LOAD MODELINGIMPACTS ONNODAL PRICESINPOOL MODELELECTRICITYMARKETS  

E-Print Network [OSTI]

REACTIVE LOAD MODELINGIMPACTS ONNODAL PRICESINPOOL MODELELECTRICITYMARKETS EttoreBompard, Enrico of the nodal prices in competitive electricity markets based on the Pool paradigm. Such prices focus of the paper is on the explicit evaluation of the impactsof the reactive load onthenodal real

Gross, George

120

1997 Pacific Northwest Loads and Resources Study.  

SciTech Connect (OSTI)

The 1997 White Book is presented in two documents: (1) this summary of Federal system and Pacific Northwest region loads and resources; and (2) a technical appendix detailing the loads and resources for each major Pacific Northwest generating utility. Data detailing Pacific Northwest non-utility generating (NUG) resources is also available upon request. This analysis updates the 1996 pacific Northwest Loads and Resources Study, published in December 1996. In this loads and resources study, resource availability is compared with a medium forecast of electricity consumption. This document analyzes the Pacific Northwest`s projected loads and available generating resources in two parts: (1) the loads and resources of the Federal system, for which BPA is the marketing agency; and (2) the larger Pacific Northwest regional power system which includes loads and resources in addition to the Federal system. This study presents the Federal system and regional analyses for the medium load forecast. This analysis projects the yearly average energy consumption and resource availability for Operating Years (OY) 1998--99 through 2007--08.

United States. Bonneville Power Administration.

1997-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "load three-junction concentrator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Load Management DSM: Past, Present & Future  

E-Print Network [OSTI]

Load Management has grown in acceptance over the past several decades as a reliable means to provide a demand-side resource of demand capacity. This paper first reviews the significant break-throughs of load management technology then sets the stage...

Gardner, E.

1994-01-01T23:59:59.000Z

122

Nonparametric models for electricity load forecasting  

E-Print Network [OSTI]

Electricity consumption is constantly evolving due to changes in people habits, technological innovations1 Nonparametric models for electricity load forecasting JANUARY 23, 2015 Yannig Goude, Vincent at University Paris-Sud 11 Orsay. His research interests are electricity load forecasting, more generally time

Genève, Université de

123

Static load testing of a heliostat drive  

SciTech Connect (OSTI)

The drive designed and built by the Solar Power Engineering Company (SPECO) for its large area heliostat failed under high wind loads during a winter storm. This report details the testing and analysis done to verify the load capabilities of the rebuilt heliostat drive. Changes in design and improvements in fabrication resulted in a usable drive. 12 figs., 7 tabs.

Grossman, J.W.

1991-10-01T23:59:59.000Z

124

Apparatus for loading a band saw blade  

DOE Patents [OSTI]

A band saw blade is loaded between pairs of guide wheels upon tensioning the blade by guiding the blade between pairs of spaced guide plates which define converging slots that converge toward the guide wheels. The approach is particularly useful in loading blades on underwater band saw machines used to cut radioactive materials. 2 figs.

Reeves, S.R.

1990-03-20T23:59:59.000Z

125

Thermionic converter in load-switching mode  

SciTech Connect (OSTI)

An electrical equivalent circuit is proposed for a thermionic electrogenerating element. It is suitable for calculation of transients in load-switching mode. Formulas are given for estimating circuit parameters. A sample numerical calculation is given for the transient between no-load and short-circuit regimes. The results may be employed to identify experimental data in the frequency domain.

Mendel'baum, M.A.; Es'kov, V.D.

1983-01-01T23:59:59.000Z

126

Load Forecast For use in Resource Adequacy  

E-Print Network [OSTI]

-term Electricity Demand Forecasting System 1) Obtain Daily Regional Temperatures 6) Estimate Daily WeatherLoad Forecast 2019 For use in Resource Adequacy Massoud Jourabchi #12;In today's presentation d l­ Load forecast methodology ­ Drivers of the forecast f i­ Treatment of conservation

127

Steam Load Reduction Guidance Emergency Management Program  

E-Print Network [OSTI]

Steam Load Reduction Guidance Emergency Management Program v October 2014 Steam_Load_Reduction_Guidance_DSRDSR 1.0 PurposeandScope Utilities provides steam to the campus community for space heating, hot water in the steam distribution system or the Central Energy Plant, the preservation of building infrastructure

Pawlowski, Wojtek

128

Concentric tube support assembly  

SciTech Connect (OSTI)

An assembly (45) includes a plurality of separate pie-shaped segments (72) forming a disk (70) around a central region (48) for retaining a plurality of tubes (46) in a concentrically spaced apart configuration. Each segment includes a support member (94) radially extending along an upstream face (96) of the segment and a plurality of annularly curved support arms (98) transversely attached to the support member and radially spaced apart from one another away from the central region for receiving respective upstream end portions of the tubes in arc-shaped spaces (100) between the arms. Each segment also includes a radial passageway (102) formed in the support member for receiving a fluid segment portion (106) and a plurality of annular passageways (104) formed in the support arms for receiving respective arm portions (108) of the fluid segment portion from the radial passageway and for conducting the respective arm portions into corresponding annular spaces (47) formed between the tubes retained by the disk.

Rubio, Mark F.; Glessner, John C.

2012-09-04T23:59:59.000Z

129

Using Utility Load Data to Estimate Demand for Space Cooling and Potential for Shiftable Loads  

SciTech Connect (OSTI)

This paper describes a simple method to estimate hourly cooling demand from historical utility load data. It compares total hourly demand to demand on cool days and compares these estimates of total cooling demand to previous regional and national estimates. Load profiles generated from this method may be used to estimate the potential for aggregated demand response or load shifting via cold storage.

Denholm, P.; Ong, S.; Booten, C.

2012-05-01T23:59:59.000Z

130

An Evaluation of the HVAC Load Potential for Providing Load Balancing Service  

SciTech Connect (OSTI)

This paper investigates the potential of providing aggregated intra-hour load balancing services using heating, ventilating, and air-conditioning (HVAC) systems. A direct-load control algorithm is presented. A temperature-priority-list method is used to dispatch the HVAC loads optimally to maintain consumer-desired indoor temperatures and load diversity. Realistic intra-hour load balancing signals were used to evaluate the operational characteristics of the HVAC load under different outdoor temperature profiles and different indoor temperature settings. The number of HVAC units needed is also investigated. Modeling results suggest that the number of HVACs needed to provide a {+-}1-MW load balancing service 24 hours a day varies significantly with baseline settings, high and low temperature settings, and the outdoor temperatures. The results demonstrate that the intra-hour load balancing service provided by HVAC loads meet the performance requirements and can become a major source of revenue for load-serving entities where the smart grid infrastructure enables direct load control over the HAVC loads.

Lu, Ning

2012-09-30T23:59:59.000Z

131

Time and Cognitive Load 1 Time and Cognitive Load in Working Memory  

E-Print Network [OSTI]

Time and Cognitive Load 1 Time and Cognitive Load in Working Memory Pierre Barrouillet*, Sophie Bourgogne Running head: Time and Cognitive Load Corresponding author: Pierre Barrouillet Pierre manuscript, published in "Journal of Experimental Psychology: Learning, Memory, and Cognition 33, 3 (2007

Paris-Sud XI, Université de

132

REVIEW OF ACTINIDE AND STRONTIUM LOADING DATA FOR MST AND MMST  

SciTech Connect (OSTI)

SRNL reviewed the relevant data from MST and mMST fissile loading studies to determine if further studies were required. With respect to MST, SRNL found that the published results adequately bound the expected conditions that Small Column Ion Exchange (SCIX) process will operate under. The lack of strontium data does not represent an issue as strontium is not relevant to criticality. There is no threat to criticality safety from the lack of strontium loading data. However, SRNL proposes a single test with MST to ensure that future SCIX operations are conservatively bounded and strontium maximum loading is understood. With respect to attempts to maximally load mMST, SRNL's knowledge on actinide and strontium loading is limited to uranium behavior. mMST has a very weak affinity for uranium, and even extended contact time at high uranium concentration shows minimal loading onto mMST. This leaves questions about the ability to load plutonium, neptunium and strontium. SRNL proposes to perform two tests with mMST to ensure that questions on plutonium, neptunium, and strontium sorption are answered, as well as ensuring that future mMST operations are conservatively bounded.

Peters, T.; Hobbs, D.; Fink, S.

2010-10-20T23:59:59.000Z

133

ENGINEERING DEPARTMENTS, DEGREES AND CONCENTRATIONS  

E-Print Network [OSTI]

ENGINEERING, CHEMISTRY AND SCIENCE (TECS) Biological Engineering (BE) Biomedical Engineering (BME) ChemicalENGINEERING DEPARTMENTS, DEGREES AND CONCENTRATIONS DEPARTMENT DEGREE CONCENTRATION (optional) BIOLOGICAL AND AGRICULTURAL ENGINEERING (BAE) BIOMEDICAL ENGINEERING (BME) CHEMICAL AND BIOMOLECULAR

134

Project Approval Form Concentration in  

E-Print Network [OSTI]

Project Approval Form Concentration in Nanotechnology Return completed form to ENG Undergraduate of Graduation:____________________________ Instructions: Please check one of the following ways in which you Plan to complete the project as a requirement for the concentration in Nanotechnology. Depending upon

Goldberg, Bennett

135

SEDIMENT CONCENTRATION BELOW FREE OVERFALL  

E-Print Network [OSTI]

SEDIMENT CONCENTRATION BELOW FREE OVERFALL By O. R. Stein,~Associate Member, ASCE, and P. Y. Julien and sediment concentration, which may affect downstream morphology and water quality as well as the structure is to determine relationships between time, scour depth, scour-hole volume, and sediment concentration generated

Julien, Pierre Y.

136

Synthesis of polyoxometalate-loaded epoxy composites  

DOE Patents [OSTI]

The synthesis of a polyoxometalate-loaded epoxy uses a one-step cure by applying an external stimulus to release the acid from the polyoxometalate and thereby catalyze the cure reaction of the epoxy resin. Such polyoxometalate-loaded epoxy composites afford the cured epoxy unique properties imparted by the intrinsic properties of the polyoxometalate. For example, polyoxometalate-loaded epoxy composites can be used as corrosion resistant epoxy coatings, for encapsulation of electronics with improved dielectric properties, and for structural applications with improved mechanical properties.

Anderson, Benjamin J

2014-10-07T23:59:59.000Z

137

Load apparatus and method for bolt-loaded compact tension test specimen  

DOE Patents [OSTI]

A bolt-loaded compact tension test specimen load apparatus includes: (a) a body having first and second opposing longitudinal ends, the first end comprising an externally threaded portion sized to be threadedly received within the test specimen threaded opening; (b) a longitudinal loading rod having first and second opposing longitudinal ends, the loading rod being slidably received in a longitudinal direction within the body internally through the externally threaded portion and slidably extending longitudinally outward of the body first longitudinal end; (c) a force sensitive transducer slidably received within the body and positioned to engage relative to the loading rod second longitudinal end; and (d) a loading bolt threadedly received relative to the body, the loading bolt having a bearing end surface and being positioned to bear against the transducer to forcibly sandwich the transducer between the loading bolt and loading rod. Also disclosed is a method of in situ determining applied force during crack propagation in a bolt-loaded compact tension test specimen. 6 figs.

Buescher, B.J. Jr.; Lloyd, W.R.; Ward, M.B.; Epstein, J.S.

1997-02-04T23:59:59.000Z

138

Load apparatus and method for bolt-loaded compact tension test specimen  

DOE Patents [OSTI]

A bolt-loaded compact tension test specimen load apparatus includes: a) a body having first and second opposing longitudinal ends, the first end comprising an externally threaded portion sized to be threadedly received within the test specimen threaded opening; b) a longitudinal loading rod having first and second opposing longitudinal ends, the loading rod being slidably received in a longitudinal direction within the body internally through the externally threaded portion and slidably extending longitudinally outward of the body first longitudinal end; c) a force sensitive transducer slidably received within the body and positioned to engage relative to the loading rod second longitudinal end; and d) a loading bolt threadedly received relative to the body, the loading bolt having a bearing end surface and being positioned to bear against the transducer to forcibly sandwich the transducer between the loading bolt and loading rod. Also disclosed is a method of in situ determining applied force during crack propagation in a bolt-loaded compact tension test specimen.

Buescher, Jr., Brent J. (Idaho Falls, ID); Lloyd, W. Randolph (Idaho Falls, ID); Ward, Michael B. (Idaho Falls, ID); Epstein, Jonathan S. (Idaho Falls, ID)

1997-01-01T23:59:59.000Z

139

Load-follow control simulation with optimization  

SciTech Connect (OSTI)

For the simulation of load-follow control operation of pressurized water reactors (PWRs), the system model needs to describe both primary and secondary system behaviors, because the load-change signal in the secondary system delivers a change in the primary system through the thermal-hydraulic interactions in the steam generator. In this study, the characteristics of load-follow control for a PWR were investigated using a one-dimensional core model combined with a simplified nuclear steam supply system model using optimization. The overall system model includes one-dimensional core neutronics with all the space-dependent feedback effects, Xe-I dynamics, core thermal balances, primary loop thermal balances, and steam generator dynamic responses to turbine load changes. The final system equations were manipulated for the lumped parameter representations by using the model expansion technique for the core model.

Yim, Man-Sung; Christenson, J.M.

1989-01-01T23:59:59.000Z

140

Modeling and control of thermostatically controlled loads  

SciTech Connect (OSTI)

As the penetration of intermittent energy sources grows substantially, loads will be required to play an increasingly important role in compensating the fast time-scale fluctuations in generated power. Recent numerical modeling of thermostatically controlled loads (TCLs) has demonstrated that such load following is feasible, but analytical models that satisfactorily quantify the aggregate power consumption of a group of TCLs are desired to enable controller design. We develop such a model for the aggregate power response of a homogeneous population of TCLs to uniform variation of all TCL setpoints. A linearized model of the response is derived, and a linear quadratic regulator (LQR) has been designed. Using the TCL setpoint as the control input, the LQR enables aggregate power to track reference signals that exhibit step, ramp and sinusoidal variations. Although much of the work assumes a homogeneous population of TCLs with deterministic dynamics, we also propose a method for probing the dynamics of systems where load characteristics are not well known.

Backhaus, Scott N [Los Alamos National Laboratory; Sinitsyn, Nikolai [Los Alamos National Laboratory; Kundu, S. [UNIV OF MICHIGAN; Hiskens, I. [UNIV OF MICHIGAN

2011-01-04T23:59:59.000Z

Note: This page contains sample records for the topic "load three-junction concentrator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Impact of load type on microgrid stability  

E-Print Network [OSTI]

Microgrids show great promise as a means of integrating distributed generation sources into the public grid distribution system. In order to provide uninterrupted,high quality power to local loads, microgrids must have the ...

Monnin, Jared P

2012-01-01T23:59:59.000Z

142

MCO loading and cask loadout technical manual  

SciTech Connect (OSTI)

A compilation of the technical basis for loading a multi-canister overpack (MCO) with spent nuclear fuel and then placing the MCO into a cask for shipment to the Cold Vacuum Drying Facility. The technical basis includes a description of the process, process technology that forms the basis for loading alternatives, process control considerations, safety considerations, equipment description, and a brief facility structure description.

PRAGA, A.N.

1998-10-01T23:59:59.000Z

143

Gearbox Reliability Collaborative (GRC) Description and Loading  

SciTech Connect (OSTI)

This document describes simulated turbine load cases in accordance to the IEC 61400-1 Ed.3 standard, which is representative of the typical wind turbine design process. The information presented herein is intended to provide a broad understanding of the gearbox reliability collaborative 750kW drivetrain and turbine configuration. In addition, fatigue and ultimate strength drivetrain loads resulting from simulations are presented. This information provides the bases for the analytical work of the gearbox reliability collaborative effort.

Oyague, F.

2011-11-01T23:59:59.000Z

144

Harmonic approaches to non-intrusive load diagnostics  

E-Print Network [OSTI]

The Non-Intrusive Load Monitor (NILM) is a system that monitors, records and processes voltage and current measurements to establish the operating characteristics of individual loads on a load center from a single aggregate ...

Fuller, Ashley E. (Ashley Eliot)

2008-01-01T23:59:59.000Z

145

Psychosocial mediators of ethnic disparities in Allostatic Load /  

E-Print Network [OSTI]

in Allostatic Load A dissertation submitted in partialPartial Associations between Posited Mediators with Ethnicity and Allostatic Load……………………………………………………………………………………Partial Associations between Posited Mediators with Ethnicity and Allostatic Load

Tomfohr, Lianne Marie

2013-01-01T23:59:59.000Z

146

axial compressive load: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

as the electromagnetic and thermal contraction loads are large but also for the heat load from the AC coupling loss. Reduction of the transverse load and warm-up cool-down...

147

axial compressive loading: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

as the electromagnetic and thermal contraction loads are large but also for the heat load from the AC coupling loss. Reduction of the transverse load and warm-up cool-down...

148

General solutions for thermopiezoelectrics with various holes under thermal loading  

E-Print Network [OSTI]

induced by thermal loads. The loads may be uniform remote heat ÂŻow, point heat source and temperature elastic plate with an hole of various shapes subjected to remote uniform mechanical loading. For plane

Qin, Qinghua

149

PO. 254 Control of Power Train Loads  

E-Print Network [OSTI]

Abstract summary Variable loads along the power train are the primary cause attributed to the failure of gears, bearings, and other mechanical components. The concept of anticipatory control applied to a wind power train is presented. This new approach to power train load management is based on the data reflecting the current status of the power train. The model driving the optimization of the power train loads considers four different objectives, including minimization of the torque variability and power maximization. A software tool for power train load management is presented. This new approach to power train load control is based on the data reflecting the current status of the power train. Such data is collected by a typical SCADA system. The model driving the optimization of the power train loads considers four different objectives, including minimization of the torque variability and power maximization. Details of the model that is applicable to different turbines are presented Objectives Goal: Transform a wind a farm into a wind power plant Example objectives: ? Minimization of the torque ramp rate ? Maximization of the power produced ? Maximization of the power quality Modify the shape of the power curve Methods Data mining/Knowledge discovery

Andrew Kusiak

150

1999 Pacific Northwest Loads and Resources Study.  

SciTech Connect (OSTI)

The Pacific Northwest Loads and Resources Study (White Book) is published annually by BPA and establishes the planning basis for supplying electricity to customers. It serves a dual purpose. First, the White Book presents projections of regional and Federal system load and resource capabilities, along with relevant definitions and explanations. Second, the White Book serves as a benchmark for annual BPA determinations made pursuant to its regional power sales contracts. Specifically, BPA uses the information in the White Book for determining the notice required when customers request to increase or decrease the amount of power purchased from BPA. The White Book will not be used in calculations for the 2002 regional power sales contract subscription process. The White Book compiles information obtained from several formalized resource planning reports and data submittals, including those from the Northwest Power Planning Council (Council) and the Pacific Northwest Utilities Conference Committee (PNUCC). The White Book is not an operational planning guide, nor is it used for determining BPA revenues. Operation of the Federal Columbia River Power System (FCRPS) is based on a set of criteria different from that used for resource planning decisions. Operational planning is dependent upon real-time or near-term knowledge of system conditions, including expectations of river flows and runoff, market opportunities, availability of reservoir storage, energy exchanges, and other factors affecting the dynamics of operating a power system. In this loads and resources study, resource availability is compared with a medium forecast of electricity consumption. The forecasted future electricity demands--firm loads--are subtracted from the projected capability of existing and ''contracted for'' resources to determine whether BPA and the region will be surplus or deficit. If Federal system resources are greater than loads in any particular year or month, there is a surplus of energy and/or capacity, which BPA may use or market to increase revenues. Conversely, if Federal system firm loads exceed available resources, there is a deficit of energy and/or capacity and BPA would add conservation or contract purchases as needed to meet its firm loads. The load forecast is derived by using econometric models and analysis to predict the loads that will be placed on electric utilities in the region. This study incorporates information on contract obligations and contract resources, combined with the resource capabilities obtained from public utility and investor-owned utility (IOU) customers through their annual data submittals to the PNUCC, from BPA's Firm Resource Exhibit (FRE Exhibit I) submittals, and through analysis of the Federal hydroelectric power system. The loads and resources analysis in this study simulates the operation of the power system under the Pacific Northwest Coordination Agreement (PNCA) produced by the Pacific Northwest Coordinating Group. The PNCA defines the planning and operation of the regional hydrosystem. The 1999 White Book is presented in two documents: (1) this summary of Federal system and Pacific Northwest region loads and resources; and (2) a technical appendix (available electronically only) detailing the loads and resources for each major Pacific Northwest generating utility. This analysis updates the December 1998 Pacific Northwest Loads and Resources Study. This analysis projects the yearly average energy consumption and resource availability for Operating Years (OY) 2000-01 through 2009-10. The study shows the Federal system's and the region's monthly estimated maximum electricity demand, monthly energy demand, monthly energy generation, and monthly maximum generating capability--capacity--for OY 2000-01, 2004-05, and 2009-10. The Federal system and regional monthly capacity surplus/deficit projections are summarized for 10 operating years. This document analyzes the Pacific Northwest's projected loads and available generating resources in two parts: (1) the loads and resources of the Federal system, for wh

United States. Bonneville Power Administration.

1999-12-01T23:59:59.000Z

151

PARKS, RECREATION & TOURISM Concentration in  

E-Print Network [OSTI]

PARKS, RECREATION & TOURISM Concentration in Conservation Law Enforcement School Experience in Parks, Recreation, and Tourism 1 Semester 5 Semester 6 SFR 434/534 - Recreation Site Planning

Thomas, Andrew

152

Concentrated solar power on demand .  

E-Print Network [OSTI]

??This thesis describes a new concentrating solar power central receiver system with integral thermal storage. Hillside mounted heliostats direct sunlight into a volumetric absorption molten… (more)

Codd, Daniel Shawn

2011-01-01T23:59:59.000Z

153

Method and apparatus for imparting strength to a material using sliding loads  

DOE Patents [OSTI]

A method of enhancing the strength of metals by affecting subsurface zones developed during the application of large sliding loads is disclosed. Stresses which develop locally within the near surface zone can be many times larger than those predicted from the applied load and the friction coefficient. These stress concentrations arise from two sources: (1) asperity interactions and (2) local and momentary bonding between the two surfaces. By controlling these parameters more desirable strength characteristics can be developed in weaker metals to provide much greater strength to rival that of steel, for example. 11 figs.

Hughes, D.A.; Dawson, D.B.; Korellis, J.S.

1999-03-16T23:59:59.000Z

154

Method and apparatus for imparting strength to a material using sliding loads  

DOE Patents [OSTI]

A method of enhancing the strength of metals by affecting subsurface zones developed during the application of large sliding loads. Stresses which develop locally within the near surface zone can be many times larger than those predicted from the applied load and the friction coefficient. These stress concentrations arise from two sources: 1) asperity interactions and 2) local and momentary bonding between the two surfaces. By controlling these parameters more desirable strength characteristics can be developed in weaker metals to provide much greater strength to rival that of steel, for example.

Hughes, Darcy Anne (Fremont, CA); Dawson, Daniel B. (Pleasanton, CA); Korellis, John S. (Livermore, CA)

1999-01-01T23:59:59.000Z

155

Method And Apparatus For Imparting Strength To Materials Using Sliding Loads  

DOE Patents [OSTI]

A method of enhancing the strength of metals by affecting subsurface zones developed during the application of large sliding loads. Stresses which develop locally within the near surface zone can be many times larger than those predicted from the applied load and the friction coefficient. These stress concentrations arise from two sources: 1) asperity interactions and 2) local and momentary bonding between the two surfaces. By controlling these parameters more desirable strength characteristics can be developed in weaker metals to provide much greater strength to rival that of steel, for example.

Hughes, Darcy Anne (Fremont, CA); Dawson, Daniel B. (Pleasanton, CA); Korellis, John S. (Livermore, CA)

1999-03-16T23:59:59.000Z

156

Transmission Reliability "Load as a Resource" Peer Review Materials...  

Broader source: Energy.gov (indexed) [DOE]

Transmission Reliability "Load as a Resource" Peer Review Materials Now Available Transmission Reliability "Load as a Resource" Peer Review Materials Now Available September 25,...

157

Y-12 Finishes Initial HEUMF Loading Ahead of Schedule | National...  

National Nuclear Security Administration (NNSA)

Home Field Offices Welcome to the NNSA Production Office NPO News Releases Y-12 Finishes Initial HEUMF Loading Ahead of Schedule Y-12 Finishes Initial HEUMF Loading...

158

acute acid loading an: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

7 queries Meagher, Mary 29 An Automatic Load Sharing Approach for a DFIG Based Wind Generator in a Microgrid Engineering Websites Summary: An Automatic Load Sharing Approach...

159

Characterization of Dynamic Loads on Solar Modules with Respect...  

Broader source: Energy.gov (indexed) [DOE]

Characterization of Dynamic Loads on Solar Modules with Respect to Fracture of Solar Cells Characterization of Dynamic Loads on Solar Modules with Respect to Fracture of Solar...

160

Effect of Compression Ratio and Piston Geometry on RCCI load...  

Broader source: Energy.gov (indexed) [DOE]

Compression Ratio and Piston Geometry on RCCI load limit Effect of Compression Ratio and Piston Geometry on RCCI load limit Explores the effect of compression ratio and piston...

Note: This page contains sample records for the topic "load three-junction concentrator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Development of an Accelerated Ash-Loading Protocol for Diesel...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

an Accelerated Ash-Loading Protocol for Diesel Particulate Filters Development of an Accelerated Ash-Loading Protocol for Diesel Particulate Filters Poster presentation at the 2007...

162

The Development of a Small Engine Based Accelerated Ash Loading...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Accelerated Ash Loading Protocol The Development of a Small Engine Based Accelerated Ash Loading Protocol Presentation given at DEER 2006, August 20-24, 2006, Detroit, Michigan....

163

Local Soot Loading Distribution in Cordierite Diesel Particulate...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Local Soot Loading Distribution in Cordierite Diesel Particulate Filters by Dynamic Neutron Radiography Local Soot Loading Distribution in Cordierite Diesel Particulate Filters by...

164

Load controller and method to enhance effective capacity of a photovoltaic power supply using a dynamically determined expected peak loading  

DOE Patents [OSTI]

A load controller and method are provided for maximizing effective capacity of a non-controllable, renewable power supply coupled to a variable electrical load also coupled to a conventional power grid. Effective capacity is enhanced by monitoring power output of the renewable supply and loading, and comparing the loading against the power output and a load adjustment threshold determined from an expected peak loading. A value for a load adjustment parameter is calculated by subtracting the renewable supply output and the load adjustment parameter from the current load. This value is then employed to control the variable load in an amount proportional to the value of the load control parameter when the parameter is within a predefined range. By so controlling the load, the effective capacity of the non-controllable, renewable power supply is increased without any attempt at operational feedback control of the renewable supply.

Perez, Richard

2005-05-03T23:59:59.000Z

165

Cast Stone Formulation At Higher Sodium Concentrations  

SciTech Connect (OSTI)

A low temperature waste form known as Cast Stone is being considered to provide supplemental Low Activity Waste (LAW) immobilization capacity for the Hanford site. Formulation of Cast Stone at high sodium concentrations is of interest since a significant reduction in the necessary volume of Cast Stone and subsequent disposal costs could be achieved if an acceptable waste form can be produced with a high sodium molarity salt solution combined with a high water to premix (or dry blend) ratio. The objectives of this study were to evaluate the factors involved with increasing the sodium concentration in Cast Stone, including production and performance properties and the retention and release of specific components of interest. Three factors were identified for the experimental matrix: the concentration of sodium in the simulated salt solution, the water to premix ratio, and the blast furnace slag portion of the premix. The salt solution simulants used in this study were formulated to represent the overall average waste composition. The cement, blast furnace slag, and fly ash were sourced from a supplier in the Hanford area in order to be representative. The test mixes were prepared in the laboratory and fresh properties were measured. Fresh density increased with increasing sodium molarity and with decreasing water to premix ratio, as expected given the individual densities of these components. Rheology measurements showed that all of the test mixes produced very fluid slurries. The fresh density and rheology data are of potential value in designing a future Cast Stone production facility. Standing water and density gradient testing showed that settling is not of particular concern for the high sodium compositions studied. Heat of hydration measurements may provide some insight into the reactions that occur within the test mixes, which may in turn be related to the properties and performance of the waste form. These measurements showed that increased sodium concentration in the salt solution reduced the time to peak heat flow, and reducing the amount of slag in the premix increased the time to peak heat flow. These observations may help to describe some of the cured properties of the samples, in particular the differences in compressive strength observed after 28 and 90 days of curing. Samples were cured for at least 28 days at ambient temperature in the laboratory prior to cured properties analyses. The low activity waste form for disposal at the Hanford Site is required to have a compressive strength of at least 500 psi. After 28 days of curing, several of the test mixes had mean compressive strengths that were below the 500 psi requirement. Higher sodium concentrations and higher water to premix ratios led to reduced compressive strength. Higher fly ash concentrations decreased the compressive strength after 28 days of curing. This may be explained in that the cementitious phases matured more quickly in the mixes with higher concentrations of slag, as evidenced by the data for the time to peak heat generation. All of the test mixes exhibited higher mean compressive strengths after 90 days of curing, with only one composition having a mean compressive strength of less than 500 psi. Leachability indices were determined for the test mixes for contaminants of interest. The leaching performance of the mixes evaluated in this study was not particularly sensitive to the factors used in the experimental design. This may be beneficial in demonstrating that the performance of the waste form is robust with respect to changes in the mix composition. The results of this study demonstrate the potential to achieve significantly higher waste loadings in Cast Stone and other low temperature, cementitious waste forms. Additional work is needed to elucidate the hydration mechanisms occurring in Cast Stone formulated with highly concentrated salt solutions since these reactions are responsible for determining the performance of the cured waste form. The thermal analyses completed in this study provide some preliminary insight, although the l

Fox, K. M.; Roberts, K. A.; Edwards, T. B.

2014-02-28T23:59:59.000Z

166

Cast Stone Formulation At Higher Sodium Concentrations  

SciTech Connect (OSTI)

A low temperature waste form known as Cast Stone is being considered to provide supplemental Low Activity Waste (LAW) immobilization capacity for the Hanford site. Formulation of Cast Stone at high sodium concentrations is of interest since a significant reduction in the necessary volume of Cast Stone and subsequent disposal costs could be achieved if an acceptable waste form can be produced with a high sodium molarity salt solution combined with a high water to premix (or dry blend) ratio. The objectives of this study were to evaluate the factors involved with increasing the sodium concentration in Cast Stone, including production and performance properties and the retention and release of specific components of interest. Three factors were identified for the experimental matrix: the concentration of sodium in the simulated salt solution, the water to premix ratio, and the blast furnace slag portion of the premix. The salt solution simulants used in this study were formulated to represent the overall average waste composition. The cement, blast furnace slag, and fly ash were sourced from a supplier in the Hanford area in order to be representative. The test mixes were prepared in the laboratory and fresh properties were measured. Fresh density increased with increasing sodium molarity and with decreasing water to premix ratio, as expected given the individual densities of these components. Rheology measurements showed that all of the test mixes produced very fluid slurries. The fresh density and rheology data are of potential value in designing a future Cast Stone production facility. Standing water and density gradient testing showed that settling is not of particular concern for the high sodium compositions studied. Heat of hydration measurements may provide some insight into the reactions that occur within the test mixes, which may in turn be related to the properties and performance of the waste form. These measurements showed that increased sodium concentration in the salt solution reduced the time to peak heat flow, and reducing the amount of slag in the premix increased the time to peak heat flow. These observations may help to describe some of the cured properties of the samples, in particular the differences in compressive strength observed after 28 and 90 days of curing. Samples were cured for at least 28 days at ambient temperature in the laboratory prior to cured properties analyses. The low activity waste form for disposal at the Hanford Site is required to have a compressive strength of at least 500 psi. After 28 days of curing, several of the test mixes had mean compressive strengths that were below the 500 psi requirement. Higher sodium concentrations and higher water to premix ratios led to reduced compressive strength. Higher fly ash concentrations decreased the compressive strength after 28 days of curing. This may be explained in that the cementitious phases matured more quickly in the mixes with higher concentrations of slag, as evidenced by the data for the time to peak heat generation. All of the test mixes exhibited higher mean compressive strengths after 90 days of curing, with only one composition having a mean compressive strength of less than 500 psi. Leach indices were determined for the test mixes for contaminants of interest. The leaching performance of the mixes evaluated in this study was not particularly sensitive to the factors used in the experimental design. This may be beneficial in demonstrating that the performance of the waste form is robust with respect to changes in the mix composition. The results of this study demonstrate the potential to achieve significantly higher waste loadings in Cast Stone and other low temperature, cementitious waste forms. Additional work is needed to elucidate the hydration mechanisms occurring in Cast Stone formulated with highly concentrated salt solutions since these reactions are responsible for determining the performance of the cured waste form. The thermal analyses completed in this study provide some preliminary insight, although the limited

Fox, K. M.; Roberts, K. A.; Edwards, T. B.

2013-09-17T23:59:59.000Z

167

Cast Stone Formulation At Higher Sodium Concentrations  

SciTech Connect (OSTI)

A low temperature waste form known as Cast Stone is being considered to provide supplemental Low Activity Waste (LAW) immobilization capacity for the Hanford site. Formulation of Cast Stone at high sodium concentrations is of interest since a significant reduction in the necessary volume of Cast Stone and subsequent disposal costs could be achieved if an acceptable waste form can be produced with a high sodium molarity salt solution combined with a high water to premix (or dry blend) ratio. The objectives of this study were to evaluate the factors involved with increasing the sodium concentration in Cast Stone, including production and performance properties and the retention and release of specific components of interest. Three factors were identified for the experimental matrix: the concentration of sodium in the simulated salt solution, the water to premix ratio, and the blast furnace slag portion of the premix. The salt solution simulants used in this study were formulated to represent the overall average waste composition. The cement, blast furnace slag, and fly ash were sourced from a supplier in the Hanford area in order to be representative. The test mixes were prepared in the laboratory and fresh properties were measured. Fresh density increased with increasing sodium molarity and with decreasing water to premix ratio, as expected given the individual densities of these components. Rheology measurements showed that all of the test mixes produced very fluid slurries. The fresh density and rheology data are of potential value in designing a future Cast Stone production facility. Standing water and density gradient testing showed that settling is not of particular concern for the high sodium compositions studied. Heat of hydration measurements may provide some insight into the reactions that occur within the test mixes, which may in turn be related to the properties and performance of the waste form. These measurements showed that increased sodium concentration in the salt solution reduced the time to peak heat flow, and reducing the amount of slag in the premix increased the time to peak heat flow. These observations may help to describe some of the cured properties of the samples, in particular the differences in compressive strength observed after 28 and 90 days of curing. Samples were cured for at least 28 days at ambient temperature in the laboratory prior to cured properties analyses. The low activity waste form for disposal at the Hanford Site is required to have a compressive strength of at least 500 psi. After 28 days of curing, several of the test mixes had mean compressive strengths that were below the 500 psi requirement. Higher sodium concentrations and higher water to premix ratios led to reduced compressive strength. Higher fly ash concentrations decreased the compressive strength after 28 days of curing. This may be explained in that the cementitious phases matured more quickly in the mixes with higher concentrations of slag, as evidenced by the data for the time to peak heat generation. All of the test mixes exhibited higher mean compressive strengths after 90 days of curing, with only one composition having a mean compressive strength of less than 500 psi. Leach indices were determined for the test mixes for contaminants of interest. The leaching performance of the mixes evaluated in this study was not particularly sensitive to the factors used in the experimental design. This may be beneficial in demonstrating that the performance of the waste form is robust with respect to changes in the mix composition. The results of this study demonstrate the potential to achieve significantly higher waste loadings in Cast Stone and other low temperature, cementitious waste forms. Additional work is needed to elucidate the hydration mechanisms occurring in Cast Stone formulated with highly concentrated salt solutions since these reactions are responsible for determining the performance of the cured waste form. The thermal analyses completed in this study provide some preliminary insight, although the limited

Fox, K. M.; Edwards, T. A.; Roberts, K. B.

2013-10-02T23:59:59.000Z

168

Process for concentrated biomass saccharification  

DOE Patents [OSTI]

Processes for saccharification of pretreated biomass to obtain high concentrations of fermentable sugars are provided. Specifically, a process was developed that uses a fed batch approach with particle size reduction to provide a high dry weight of biomass content enzymatic saccharification reaction, which produces a high sugars concentration hydrolysate, using a low cost reactor system.

Hennessey, Susan M. (Avondale, PA); Seapan, Mayis (Landenberg, PA); Elander, Richard T. (Evergreen, CO); Tucker, Melvin P. (Lakewood, CO)

2010-10-05T23:59:59.000Z

169

Declaration of Concentration in Nanotechnology  

E-Print Network [OSTI]

Declaration of Concentration in Nanotechnology Return completed form to ENG Undergraduate Records:____________________________ Instructions: ENG students declaring a Concentration in Nanotechnology should complete this form, obtain REQUIRED COURSES (Choose 1) 1. ENG EC 481­ Fundamentals of Nanomaterials and Nanotechnology 4.0 ELECTIVES

Goldberg, Bennett

170

2006 Pacific Northwest Loads and Resources Study.  

SciTech Connect (OSTI)

The Pacific Northwest Loads and Resources Study (White Book), which is published annually by the Bonneville Power Administration (BPA), establishes one of the planning bases for supplying electricity to customers. The White Book contains projections of regional and Federal system load and resource capabilities, along with relevant definitions and explanations. The White Book also contains information obtained from formalized resource planning reports and data submittals including those from individual utilities, the Northwest Power and Conservation Council (Council), and the Pacific Northwest Utilities Conference Committee (PNUCC). The White Book is not an operational planning guide, nor is it used for determining BPA revenues, although the database that generates the data for the White Book analysis contributes to the development of BPA's inventory and ratemaking processes. Operation of the Federal Columbia River Power System (FCRPS) is based on a set of criteria different from that used for resource planning decisions. Operational planning is dependent upon real-time or near-term knowledge of system conditions that include expectations of river flows and runoff, market opportunities, availability of reservoir storage, energy exchanges, and other factors affecting the dynamics of operating a power system. The load resource balance of both the Federal system and the region is determined by comparing resource availability to an expected level of total retail electricity consumption. Resources include projected energy capability plus contract purchases. Loads include a forecast of retail obligations plus contract obligations. Surplus energy is available when resources are greater than loads. This surplus energy could be marketed to increase revenues. Energy deficits occur when resources are less than loads. These energy deficits will be met by any combination of the following: better-than-critical water conditions, demand-side management and conservation programs, permanent loss of loads due to economic conditions or closures, additional contract purchases, and/or the addition of new generating resources. This study incorporates information on Pacific Northwest (PNW) regional retail loads, contract obligations, and contract resources. This loads and resources analysis simulates the operation of the power system in the PNW. The simulated hydro operation incorporates plant characteristics, streamflows, and non-power requirements from the current Pacific Northwest Coordination Agreement (PNCA). Additional resource capability estimates were provided by BPA, PNW Federal agency, public agency, cooperative, U.S. Bureau of Reclamation (USBR), and investor-owned utility (IOU) customers furnished through annual PNUCC data submittals for 2005 and/or direct submittals to BPA. The 2006 White Book is presented in two documents: (1) this summary document of Federal system and PNW region loads and resources, and (2) a technical appendix which presents regional loads, grouped by major PNW utility categories, and detailed contract and resource information. The technical appendix is available only in electronic form. Individual customer information for marketer contracts is not detailed due to confidentiality agreements. The 2006 White Book analysis updates the 2004 White Book. This analysis shows projections of the Federal system and region's yearly average annual energy consumption and resource availability for the study period, OY 2007-2016. The study also presents projections of Federal system and region expected 1-hour monthly peak demand, monthly energy demand, monthly 1-hour peak generating capability, and monthly energy generation for OY 2007, 2011, and 2016. BPA is investigating a new approach in capacity planning depicting the monthly Federal system 120-hour peak generating capability and 120-hour peak surplus/deficit for OY 2007, 2011, and 2016. This document analyzes the PNW's projected loads and available generating resources in two parts: (1) the loads and resources of the Federal system, for which BPA is the marketing agency;

United States. Bonneville Power Administration.

2006-03-01T23:59:59.000Z

171

On-line Load Balancing for Related Machines 1 Piotr Berman  

E-Print Network [OSTI]

s and Load(s), the load of entire schedule s as follows: load(s;i) = 1 vi X s(j)=i pj; Load(s) = maxi loadOn-line Load Balancing for Related Machines 1 (Revised Version) Piotr Berman The Pennsylvania State for this problem. Key Words: on-line algorithm, load balancing, related machines, competitive ratio 1A preliminary

Eckmiller, Rolf

172

Dielectric breakdown model for conductor-loaded and insulator-loaded composite materials P. Bergero,1  

E-Print Network [OSTI]

Dielectric breakdown model for conductor-loaded and insulator-loaded composite materials P. Bergero strength is highly desirable, and in the past years composite materials such as resin matrix filled- tors, and composites containing carbon black and titanium dioxide have recently been tested

Peruani, Fernando

173

Reconstruction of a wind turbine's endured load spectrum using a short-time load measurement  

E-Print Network [OSTI]

Reconstruction of a wind turbine's endured load spectrum using a short-time load measurement Abstract Wind turbines (WT) are normally designed for a service life (SL) of 20 years. In Germany, over safety. 1 Introduction A wind turbine (WT) is normally designed, tested and certified for a design life

Berlin,Technische Universität

174

Improved Load Distribution for Load Rating of Low-Fill Box Structures  

E-Print Network [OSTI]

. The distribution of live loads on the top slab of a box culvert plays a major role in determining the rating factor of the culvert. The current AASHTO guidelines do not consider the effects of pavements present above the fill while determining the load distribution...

Acharya, Raju

2012-12-31T23:59:59.000Z

175

Modality Effects on Cognitive Load and Performance in High-Load Information Presentation  

E-Print Network [OSTI]

INTRODUCTION Intelligent human-computer interfaces are often multimodal, i.e. the human-computer communications into the modality planning procedure for systems that support high-load human-computer interaction. Author Keywords-load information presenta- tion scenario. Mainly based on modality-related psychology theories, we selected five

Nijholt, Anton

176

Independent review of estimated load reductions for PJM's small customer load response pilot project  

E-Print Network [OSTI]

water heater (EWH) load control program operated as part of PJM Interconnection’s Demand ResponseDemand Response Economic and Emergency Load Response Programs Electric Thermal Storage Electric Water Heaterwater pumps and electric thermal storage space heaters. The CSP is also participating in PJM’s pilot Demand Response

Heffner, G.; Moezzi, M.; Goldman, C.

2004-01-01T23:59:59.000Z

177

Load attenuating passively adaptive wind turbine blade  

DOE Patents [OSTI]

A method and apparatus for improving wind turbine performance by alleviating loads and controlling the rotor. The invention employs the use of a passively adaptive blade that senses the wind velocity or rotational speed, and accordingly modifies its aerodynamic configuration. The invention exploits the load mitigation prospects of a blade that twists toward feather as it bends. The invention includes passively adaptive wind turbine rotors or blades with currently preferred power control features. The apparatus is a composite fiber horizontal axis wind-turbine blade, in which a substantial majority of fibers in the blade skin are inclined at angles of between 15 and 30 degrees to the axis of the blade, to produces passive adaptive aeroelastic tailoring (bend-twist coupling) to alleviate loading without unduly jeopardizing performance.

Veers, Paul S. (Albuquerque, NM); Lobitz, Donald W. (Albuquerque, NM)

2003-01-01T23:59:59.000Z

178

MEASUREMENT OF WASTE LOADING IN SALTSTONE  

SciTech Connect (OSTI)

One of the goals of the Saltstone variability study is to identify the operational and compositional variables that control or influence the important processing and performance properties of Saltstone grout mixtures. One of those properties of importance is the Waste Loading (WL) of the decontaminated salt solution (DSS) in the Saltstone waste form. Waste loading is a measure of the amount of waste that can be incorporated within a waste form. The value of the Saltstone waste loading ultimately determines the number of vaults that will be required to disposition all of the DSS. In this report, the waste loading is defined as the volume in milliliters of DSS per liter of Saltstone waste form. The two most important parameters that determine waste loading for Saltstone are water to cementitious material (w/cm) ratio and the cured grout density. Data are provided that show the dependence of waste loading on the w/cm ratio for a fixed DSS composition using the current premix material (45% Blast Furnace Slag (BFS), 45% Fly Ash (FA) and 10% Ordinary Portland Cement (OPC)). The impact of cured grout density on waste loading was also demonstrated. Mixes (at 0.60 w/cm) made with a Modular Caustic side extraction Unit (MCU) simulant and either OPC or BFS have higher cured grout densities than mixes made with premix and increase the WL to 709 mL/L for the OPC mix and 689 mL/L for the BFS mix versus the value of 653 mL/L for MCU in premix at 0.60 w/cm ratio. Bleed liquid reduces the waste loading and lowers the effective w/cm ratio of Saltstone. A method is presented (and will be used in future tasks) for correcting the waste loading and the w/cm ratio of the as-batched mixes in those cases where bleed liquid is present. For example, the Deliquification, Dissolution and Adjustment (DDA) mix at an as-batched 0.60 w/cm ratio, when corrected for % bleed, gives a mix with a 0.55 w/cm ratio and a WL that has been reduced from 662 to 625 mL/L. An example is provided that demonstrated the quantitative impact of WL on the number of cells (each Saltstone vault contains two cells) required to disposition all of the {approx}100 million gallons of DSS available in the tanks. This calculation revealed that the number of cells required over the range of 0.48 to 0.62 w/cm ratio (equivalent to a WL range of 591 to 666 mL/L) varies from 65 to 57 cells (33 to 29 vaults). The intent of this oversimplified example was to show the range of variation in vaults expected due to w/cm ratio rather than to estimate the actual number of vaults required. There is a tradeoff between the waste loading and the processing and performance properties of Saltstone. The performance properties improve in general as the w/cm ratio decreases whereas the waste loading is reduced at lower w/cm ratios resulting in a larger number of Saltstone vaults. The final performance and processing requirements of Saltstone will determine the maximum waste loading achievable.

Harbour, J; Vickie Williams, V

2008-07-18T23:59:59.000Z

179

Load attenuating passively adaptive wind turbine blade  

DOE Patents [OSTI]

A method and apparatus for improving wind turbine performance by alleviating loads and controlling the rotor. The invention employs the use of a passively adaptive blade that senses the wind velocity or rotational speed, and accordingly modifies its aerodynamic configuration. The invention exploits the load mitigation prospects of a blade that twists toward feather as it bends. The invention includes passively adaptive wind turbine rotors or blades with currently preferred power control features. The apparatus is a composite fiber horizontal axis wind-turbine blade, in which a substantial majority of fibers in the blade skin are inclined at angles of between 15 and 30 degrees to the axis of the blade, to produces passive adaptive aeroelastic tailoring (bend-twist coupling) to alleviate loading without unduly jeopardizing performance.

Veers, Paul S.; Lobitz, Donald W.

2003-01-07T23:59:59.000Z

180

IN-SERVICE LOAD & RESISTANCE FACTOR RATING METHOD FOR BRIDGES  

E-Print Network [OSTI]

Stress Rating method (noted ASR in the following), Load Factor Rating method (noted LFR in the followingIN-SERVICE LOAD & RESISTANCE FACTOR RATING METHOD FOR BRIDGES Degang Li1 , Baidurya Bhattacharya2 are evaluated using allowable stress and load factor rating methods. Load rating made in these traditional

Bhattacharya, Baidurya

Note: This page contains sample records for the topic "load three-junction concentrator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Randomized Load Balancing by Joining and Splitting Bins James Aspnes  

E-Print Network [OSTI]

Consider the following load balancing scenario: a certain amount of work load is distributed among a setRandomized Load Balancing by Joining and Splitting Bins James Aspnes Yitong Yin § 1 Introduction, one of the existing machines gives some of its load to the new machine; and upon a departure

Aspnes, James

182

Classification and forecasting of load curves Nolwen Huet  

E-Print Network [OSTI]

Classification and forecasting of load curves Nolwen Huet Abstract The load curve, which gives of electricity customer uses. This load curve is only available for customers with automated meter reading. For the others, EDF must estimate this curve. Usually a clustering of the load curves is performed, followed

Cuesta, Juan Antonio

183

Discharge indices for water quality loads Richard M. Vogel  

E-Print Network [OSTI]

: effective discharge, transport, sediment, constituents, rating curve, half-load Citation: Vogel, R. M., J. RDischarge indices for water quality loads Richard M. Vogel Department of Civil and Environmental load is ultimately the quantity of interest, we define a new index, the half-load discharge, which

Vogel, Richard M.

184

ANALYTICAL APPROACH TO TRANSIENT HEAT CONDUCTION IN COOLING LOAD CALCULATIONS  

E-Print Network [OSTI]

equation in cooling load calculations. The performance of nine different procedures (the four methods and

Michal Duška; Martin Barták; František Drkal; Jan Hensen

185

Demand-Side Response from Industrial Loads  

SciTech Connect (OSTI)

Through a research study funded by the Department of Energy, Smart Grid solutions company ENBALA Power Networks along with the Oak Ridge National Laboratory (ORNL) have geospatially quantified the potential flexibility within industrial loads to leverage their inherent process storage to help support the management of the electricity grid. The study found that there is an excess of 12 GW of demand-side load flexibility available in a select list of top industrial facilities in the United States. Future studies will expand on this quantity of flexibility as more in-depth analysis of different industries is conducted and demonstrations are completed.

Starke, Michael R [ORNL; Alkadi, Nasr E [ORNL; Letto, Daryl [Enbala Power Networks; Johnson, Brandon [University of Tennessee, Knoxville (UTK); Dowling, Kevin [University of Tennessee, Knoxville (UTK); George, Raoule [Enbala Power Networks; Khan, Saqib [University of Texas, Austin

2013-01-01T23:59:59.000Z

186

Taking a Bite out of Lighting Loads  

E-Print Network [OSTI]

Take a Bite Out of Lighting Loads With LEDs Stephen Williams Toshiba Sales Support Manager ESL-KT-13-12-34 CATEE 2013: Clean Air Through Energy Efficiency Conference, San Antonio, Texas Dec. 16-18 Some LED Advantages • Less electricity ? 18w LED... = 100w PAR38 • No maintenance for years ? 50,000 LED vs.10,000 CFL • Improved light quality ? 80 CRI LED vs. 25 CRI HPS • Reduce HVAC cooling load • Advanced control options ESL-KT-13-12-34 CATEE 2013: Clean Air Through Energy Efficiency Conference, San...

Williams, S.

2013-01-01T23:59:59.000Z

187

Hexavalent chromium at low concentration alters Sertoli cell barrier and connexin 43 gap junction but not claudin-11 and N-cadherin in the rat seminiferous tubule culture model  

SciTech Connect (OSTI)

Exposure to toxic metals, specifically those belonging to the nonessential group leads to human health defects and among them reprotoxic effects. The mechanisms by which these metals produce their negative effects on spermatogenesis have not been fully elucidated. By using the Durand's validated seminiferous tubule culture model, which mimics the in vivo situation, we recently reported that concentrations of hexavalent chromium, reported in the literature to be closed to that found in the blood circulation of men, increase the number of germ cell cytogenetic abnormalities. Since this metal is also known to affect cellular junctions, we investigated, in the present study, its potential influence on the Sertoli cell barrier and on junctional proteins present at this level such as connexin 43, claudin-11 and N-cadherin. Cultured seminiferous tubules in bicameral chambers expressed the three junctional proteins and ZO-1 for at least 12 days. Exposure to low concentrations of chromium (10 ?g/l) increased the trans-epithelial resistance without major changes of claudin-11 and N-cadherin expressions but strongly delocalized the gap junction protein connexin 43 from the membrane to the cytoplasm of Sertoli cells. The possibility that the hexavalent chromium-induced alteration of connexin 43 indirectly mediates the effect of the toxic metal on the blood–testis barrier dynamic is postulated. - Highlights: ? Influence of Cr(VI) on the Sertoli cell barrier and on junctional proteins ? Use of cultured seminiferous tubules in bicameral chambers ? Low concentrations of Cr(VI) (10 ?g/l) altered the trans-epithelial resistance. ? Cr(VI) did not alter claudin-11 and N-cadherin. ? Cr(VI) delocalized connexin 43 from the membrane to the cytoplasm of Sertoli cells.

Carette, Diane [INSERM U 1065, Team 5 “Physiopathology of Germ Cell Control: Genomic and Non Genomic Mechanisms” C3M, University of Nice Sophia Antipolis, Nice (France); UMR S775, University Paris Descartes, 45 rue des Saints Pčres, 75006, Paris (France); Perrard, Marie-Hélčne, E-mail: marie-helene.durand@ens-lyon.fr [Institut de Génomique Fonctionnelle de Lyon, Université de Lyon, Université Lyon I, CNRS, INRA, Ecole Normale Supérieure de Lyon, Lyon (France); Prisant, Nadia [University of Versailles/St Quentin-en-Yvelines (France); UMR S775, University Paris Descartes, 45 rue des Saints Pčres, 75006, Paris (France); Gilleron, Jérome; Pointis, Georges [INSERM U 1065, Team 5 “Physiopathology of Germ Cell Control: Genomic and Non Genomic Mechanisms” C3M, University of Nice Sophia Antipolis, Nice (France); Segretain, Dominique [University of Versailles/St Quentin-en-Yvelines (France); UMR S775, University Paris Descartes, 45 rue des Saints Pčres, 75006, Paris (France); Durand, Philippe [Institut de Génomique Fonctionnelle de Lyon, Université de Lyon, Université Lyon I, CNRS, INRA, Ecole Normale Supérieure de Lyon, Lyon (France); Kallistem SAS Ecole Normale Supérieure de Lyon, Lyon (France)

2013-04-01T23:59:59.000Z

188

Concentrated Thermoelectric Power | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Concentrated Thermoelectric Power This fact sheet describes a concentrated solar hydroelectric power project awarded under the DOE's 2012 SunShot Concentrating Solar Power R&D...

189

Capacity Value of Concentrating Solar Power Plants  

SciTech Connect (OSTI)

This study estimates the capacity value of a concentrating solar power (CSP) plant at a variety of locations within the western United States. This is done by optimizing the operation of the CSP plant and by using the effective load carrying capability (ELCC) metric, which is a standard reliability-based capacity value estimation technique. Although the ELCC metric is the most accurate estimation technique, we show that a simpler capacity-factor-based approximation method can closely estimate the ELCC value. Without storage, the capacity value of CSP plants varies widely depending on the year and solar multiple. The average capacity value of plants evaluated ranged from 45%?90% with a solar multiple range of 1.0-1.5. When introducing thermal energy storage (TES), the capacity value of the CSP plant is more difficult to estimate since one must account for energy in storage. We apply a capacity-factor-based technique under two different market settings: an energy-only market and an energy and capacity market. Our results show that adding TES to a CSP plant can increase its capacity value significantly at all of the locations. Adding a single hour of TES significantly increases the capacity value above the no-TES case, and with four hours of storage or more, the average capacity value at all locations exceeds 90%.

Madaeni, S. H.; Sioshansi, R.; Denholm, P.

2011-06-01T23:59:59.000Z

190

Design of inflatable solar concentrator  

E-Print Network [OSTI]

Solar concentrators improve the performance of solar collection systems by increasing the amount of usable energy available for a given collector size. Unfortunately, they are not known for their light weight and portability, ...

Carrasquillo, Omar (Omar Y. Carrasquillo De Armas)

2013-01-01T23:59:59.000Z

191

Optimal concentrations in nectar feeding  

E-Print Network [OSTI]

Nectar drinkers must feed quickly and efficiently due to the threat of predation. While the sweetest nectar offers the greatest energetic rewards, the sharp increase of viscosity with sugar concentration makes it the most ...

Kim, Wonjung

192

Concentrated solar power on demand  

E-Print Network [OSTI]

This thesis describes a new concentrating solar power central receiver system with integral thermal storage. Hillside mounted heliostats direct sunlight into a volumetric absorption molten salt pool, which also functions ...

Codd, Daniel Shawn

2011-01-01T23:59:59.000Z

193

A Note on Online Load Balancing for Related Machines  

E-Print Network [OSTI]

(j) that will execute it. We define the load of a machine i and the load of entire schedule s as follows: load(s; i) = 1A Note on On­line Load Balancing for Related Machines Piotr Berman \\Lambda Marek Karpinski y that differ in speed but are related in the following sence: a job of size p requires time p=v on a machine

Eckmiller, Rolf

194

Independent review of estimated load reductions for PJM's small customer load response pilot project  

SciTech Connect (OSTI)

This study describes the results of a low-cost approach used to measure reported load reductions from a residential electric water heater (EWH) load control program operated as part of PJM Interconnection's Demand Response small customer pilot program. Lawrence Berkeley National Laboratory (LBNL) conducted this independent review of the engineering estimates for EWH load control reported by a Curtailment Service Provider (CSP) at PJM's request. LBNL employed low-cost measurement and verification (M&V) approaches that utilized existing interval metering equipment to monitor results for a series of load control tests. The CSP collected hourly load data for two substations and several hundred households over a six-week period in October and November 2003. During this time period, the CSP operated its electric water heater load control program during pre-specified test periods in the morning, afternoon and early evening. LBNL then analyzed substation and premise-level data from these tests in order to verify the diversified demand reductions claimed by the CSP for customers participating in the EWH load control program. We found that the observed load reductions for the premise-level data aggregated over all households in the two participating electric cooperatives were, respectively, 40 percent-60 percent less and 3 percent less-10 percent higher than the estimated diversified demand reduction values assumed by the CSP, depending on whether observed or normalized results are considered. We also analyzed sub-station level data and found that the observed load reductions during the test periods were significantly lower than expected, although confounding influences and operational problems signifiogram during pre-specified test periods in the morning, afternoon and early evening. LBNL then analyzed substation and premise-level data from these tests in order to verify the diversified demand reductions claimed by the CSP for customers participating in the EWH load control program. We found that the observed load reductions for the premise-level data aggregated over all households in the two participating electric cooperatives were, respectively, 40 percent-60 percent less and 3 percent less-10 percent higher than the estimated diversified demand reduction values assumed by the CSP, depending on whether observed or normalized results are considered. We also analyzed sub-station level data and found that the observed load reductions during the test periods were significantly lower than expected, although confounding influences and operational problems significantly limit our ability to differentiate between control-related and non-control related differences in substation-level load shape data. The usefulness and accuracy of the results were hampered by operational problems encountered during the measurement period as well as in sufficient number of load research grade interval meters at one cooperative. Given the larger sample size at one electric cooperative and more statistically-robust results, there is some basis to suggest that the Adjusted Diversified Demand Factor (ADDF) values used by the CSP somewhat over-state the actual load reductions. Given the results and limitations of the M&V approach as implemented, we suggest several options for PJM to consider: (1) require load aggregators participating in ISODR programs to utilize formal PURPA-compliant load research samples in their M&V plans, and (2) continue developing lower cost M&V approaches for mass market load control programs that incorporate suggested improvements described in this study.

Heffner, G.; Moezzi, M.; Goldman, C.

2004-06-01T23:59:59.000Z

195

Analysis of the Load Impacts and Economic  

E-Print Network [OSTI]

of the Time of Use (TOU) rate plan, called "Analysis of the Load Impacts and Economic Benefits model. The TOU data was rerun through the new spreadsheet model and the results are reported here. · Participation in the TOU rate option also resulted in an average net reduction of 292 kWh/year in annual

196

Improving Electric Load Forecasts Using Network Committees  

E-Print Network [OSTI]

, King Fahd University of Petroleum and Minerals, Dhahran 31261, Saudi Arabia Address for corresponding author: Dr. R. E. Abdel-Aal P. O. Box 1759 KFUPM Dhahran 31261 Saudi Arabia e-mail: radwan load and weather data at power utilities has encouraged the use of data-based machine learning modeling

Abdel-Aal, Radwan E.

197

Fig. 1. Example System phase loads  

E-Print Network [OSTI]

power system (SPS) consists of various components such as generators, cables, switchboards, load centers Transformer 9 25 12 Alternate path Generator switchboard Bus-tie breaker Generator 1 Generator 3 Generator 2 4 26 G 29 7 8 ABT 3 single phase cables Visualization for Shipboard Power Systems Karen L. Butler

198

Load forecast and treatment of conservation  

E-Print Network [OSTI]

conservation is implicitly incorporated in the short-term demand forecast? #12;3 Incorporating conservationLoad forecast and treatment of conservation July 28th 2010 Resource Adequacy Technical Committee in the short-term model Our short-term model is an econometric model which can not explicitly forecast

199

Load responsive multilayer insulation performance testing  

SciTech Connect (OSTI)

Cryogenic insulation designed to operate at various pressures from one atmosphere to vacuum, with high thermal performance and light weight, is needed for cryogenically fueled space launch vehicles and aircraft. Multilayer insulation (MLI) performs well in a high vacuum, but the required vacuum shell for use in the atmosphere is heavy. Spray-on foam insulation (SOFI) is often used in these systems because of its light weight, but can have a higher heat flux than desired. We report on the continued development of Load Responsive Multilayer Insulation (LRMLI), an advanced thermal insulation system that uses dynamic beam discrete spacers that provide high thermal performance both in atmosphere and vacuum. LRMLI consists of layers of thermal radiation barriers separated and supported by micromolded polymer spacers. The spacers have low thermal conductance, and self-support a thin, lightweight vacuum shell that provides internal high vacuum in the insulation. The dynamic load responsive spacers compress to support the external load of a vacuum shell in one atmosphere, and decompress under reduced atmospheric pressure for lower heat leak. Structural load testing was performed on the spacers with various configurations. LRMLI was installed on a 400 liter tank and boil off testing with liquid nitrogen performed at various chamber pressures from one atmosphere to high vacuum. Testing was also performed with an MLI blanket on the outside of the LRMLI.

Dye, S.; Kopelove, A. [Quest Thermal Group, 6452 Fig Street Suite A, Arvada, CO 80004 (United States); Mills, G. L. [Ball Aerospace and Technologies Corp, 1600 Commerce Street, Boulder, CO 80301 (United States)

2014-01-29T23:59:59.000Z

200

Valve for fuel pin loading system  

DOE Patents [OSTI]

A cyclone valve surrounds a wall opening through which cladding is projected. An axial valve inlet surrounds the cladding. Air is drawn through the inlet by a cyclone stream within the valve. An inflatable seal is included to physically engage a fuel pin subassembly during loading of fuel pellets.

Christiansen, D.W.

1984-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "load three-junction concentrator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Valve for fuel pin loading system  

DOE Patents [OSTI]

A cyclone valve surrounds a wall opening through which cladding is projected. An axial valve inlet surrounds the cladding. Air is drawn through the inlet by a cyclone stream within the valve. An inflatable seal is included to physically engage a fuel pin subassembly during loading of fuel pellets.

Christiansen, David W. (Kennewick, WA)

1985-01-01T23:59:59.000Z

202

Fuel loading and homogeneity analysis of HFIR design fuel plates loaded with uranium silicide fuel  

SciTech Connect (OSTI)

Twelve nuclear reactor fuel plates were analyzed for fuel loading and fuel loading homogeneity by measuring the attenuation of a collimated X-ray beam as it passed through the plates. The plates were identical to those used by the High Flux Isotope Reactor (HFIR) but were loaded with uranium silicide rather than with HFIR`s uranium oxide fuel. Systematic deviations from nominal fuel loading were observed as higher loading near the center of the plates and underloading near the radial edges. These deviations were within those allowed by HFIR specifications. The report begins with a brief background on the thermal-hydraulic uncertainty analysis for the Advanced Neutron Source (ANS) Reactor that motivated a statistical description of fuel loading and homogeneity. The body of the report addresses the homogeneity measurement techniques employed, the numerical correction required to account for a difference in fuel types, and the statistical analysis of the resulting data. This statistical analysis pertains to local variation in fuel loading, as well as to ``hot segment`` analysis of narrow axial regions along the plate and ``hot streak`` analysis, the cumulative effect of hot segment loading variation. The data for all twelve plates were compiled and divided into 20 regions for analysis, with each region represented by a mean and a standard deviation to report percent deviation from nominal fuel loading. The central regions of the plates showed mean values of about +3% deviation, while the edge regions showed mean values of about {minus}7% deviation. The data within these regions roughly approximated random samplings from normal distributions, although the chi-square ({chi}{sup 2}) test for goodness of fit to normal distributions was not satisfied.

Blumenfeld, P.E.

1995-08-01T23:59:59.000Z

203

2004 Pacific Northwest Loads and Resources Study.  

SciTech Connect (OSTI)

The Pacific Northwest Loads and Resources Study (White Book), which is published annually by the Bonneville Power Administration (BPA), establishes one of the planning bases for supplying electricity to customers. The White Book contains projections of regional and Federal system load and resource capabilities, along with relevant definitions and explanations. The White Book also contains information obtained from formalized resource planning reports and data submittals including those from individual utilities, the Northwest Power and Conservation Council (Council), and the Pacific Northwest Utilities Conference Committee (PNUCC). The White Book is not an operational planning guide, nor is it used for determining BPA revenues, although the database that generates the data for the White Book analysis contributes to the development of BPA's inventory and ratemaking processes. Operation of the Federal Columbia River Power System (FCRPS) is based on a set of criteria different from that used for resource planning decisions. Operational planning is dependent upon real-time or near-term knowledge of system conditions that include expectations of river flows and runoff, market opportunities, availability of reservoir storage, energy exchanges, and other factors affecting the dynamics of operating a power system. The load resource balance of BPA and/or the region is determined by comparing resource availability to an expected level of total retail electricity consumption. Resources include projected energy capability plus contract purchases. Loads include a forecast of retail obligations plus contract obligations. Surplus energy is available when resources are greater than loads. This energy could be marketed to increase revenues. Energy deficits occur when resources are less than loads. These deficits could be met by any combination of the following: better-than-critical water conditions, demand-side management and conservation programs, permanent loss of loads due to economic conditions or closures, additional contract purchases, and/or the addition of new generating resources. The loads and resources analysis in this study simulates the operation of the power system under the current Pacific Northwest Coordination Agreement (PNCA). The PNCA defines the planning and operation of seventeen U.S. Pacific Northwest utilities and other parties with generating facilities within the region's hydroelectric (hydro) system. The hydroregulation study used for the 2004 White Book incorporates measures from the National Oceanographic and Atmospheric Administration Fisheries (NOAA Fisheries) Biological Opinion dated December 2000, and the U.S. Fish and Wildlife Service's 2000 Biological Opinion (2000 FCRPS BiOps) for the Snake River and Columbia River projects. These measures include: (1) Increased flow augmentation for juvenile fish migrations in the Snake and Columbia rivers in the spring and summer; (2) Mandatory spill requirements at the Lower Snake and Columbia dams to provide for non-turbine passage routes for juvenile fish migrants; and (3) Additional flows for Kootenai River white sturgeon in the spring; The hydroregulation criteria for this analysis includes the following: (1) Detailed Operation Plan operation for Treaty reservoirs for Operating Year (OY) 2004; (2) PNCA planning criteria for OY 2004; and (3) Juvenile fish bypass spill levels for 2000 FCRPS BiOps implementation. The 2004 White Book is presented in two documents: (1) this summary document of Federal system and PNW region loads and resources, and (2) a technical appendix which presents regional loads, grouped by major PNW utility categories, and detailed contract and resource information. The technical appendix is available only in electronic form. Individual customer information for marketer contracts is not detailed due to confidentiality agreements. The 2004 White Book analysis updates the 2003 White Book. This analysis projects the yearly average energy consumption and resource availability for the study period, OY 2006 through 2015. The study shows the Federal s

United States. Bonneville Power Administration.

2004-12-01T23:59:59.000Z

204

2003 Pacific Northwest Loads and Resources Study.  

SciTech Connect (OSTI)

The Pacific Northwest Loads and Resources Study (White Book), which is published annually by the Bonneville Power Administration (BPA), establishes one of the planning bases for supplying electricity to customers. The White Book contains projections of regional and Federal system load and resource capabilities, along with relevant definitions and explanations. The White Book also contains information obtained from formalized resource planning reports and data submittals including those from individual utilities, the Northwest Power and Conservation Council (Council), and the Pacific Northwest Utilities Conference Committee (PNUCC). The White Book is not an operational planning guide, nor is it used for determining BPA revenues, although the database that generates the data for the White Book analysis contributes to the development of BPA's inventory and ratemaking processes. Operation of the Federal Columbia River Power System (FCRPS) is based on a set of criteria different from that used for resource planning decisions. Operational planning is dependent upon real-time or near-term knowledge of system conditions that include expectations of river flows and runoff, market opportunities, availability of reservoir storage, energy exchanges, and other factors affecting the dynamics of operating a power system. In this loads and resources study, resource availability is compared to an expected level of total retail electricity consumption. The forecasted annual energy electricity retail load plus contract obligations are subtracted from the sum of the projected annual energy capability of existing resources and contract purchases to determine whether BPA and/or the region will be surplus or deficit. Surplus energy is available when resources are greater than loads. This energy could be marketed to increase revenues. Deficits occur when resources are less than loads. Energy deficits could be met by any combination of the following: better-than-critical water conditions, demand-side management and conservation programs, permanent loss of a load (i.e., due to economic conditions or closures), additional contract purchases, and/or new generating resources. The loads and resources analysis in this study simulates the operation of the power system under the Pacific Northwest Coordination Agreement (PNCA). The PNCA defines the planning and operation of seventeen U.S. Pacific Northwest utilities and other parties with generating facilities within the region's hydroelectric (hydro) system. The hydroregulation study used for the 2003 White Book incorporates measures from the National Oceanographic and Atmospheric Administration Fisheries (NOAA Fisheries) Biological Opinion dated December 2000, and the U.S. Fish and Wildlife Service's 2000 Biological Opinion (2000 FCRPS BiOps) for the Snake River and Columbia River projects. These measures include: (1) Increased flow augmentation for juvenile fish migrations in the Snake and Columbia rivers in the spring and summer; (2) Mandatory spill requirements at the Lower Snake and Columbia dams to provide for non-turbine passage routes for juvenile fish migrants; and (3) Additional flows for Kootenai River white sturgeon in the spring. The hydroregulation criteria for this analysis includes: an updated Detailed Operation Plan for Treaty reservoirs for Operating Year (OY) 2004, updated PNCA planning criteria for OY 2003, and revised juvenile fish bypass spill levels for 2000 FCRPS BiOps implementation. The 2003 White Book is presented in two documents: (1) this summary document of Federal system and PNW region loads and resources, and (2) a technical appendix which presents regional loads, grouped by major PNW utility categories, and detailed contract and resource information. The technical appendix is available only in electronic form. Individual customer information regarding marketer contracts is not detailed due to confidentiality agreements. The 2003 White Book analysis updates the December 2002 White Book. This analysis projects the yearly average energy consumption and resource availability

United States. Bonneville Power Administration.

2003-12-01T23:59:59.000Z

205

Estimating suspended sediment concentrations in areas with limited hydrological data using a mixed-effects model  

E-Print Network [OSTI]

Estimating suspended sediment concentrations in areas with limited hydrological data using a mixed of Geography, Simon Fraser University, Burnaby, British Columbia, Canada Abstract: Sediment rating curves are commonly used to estimate the suspended sediment load in rivers and streams under the assumption

Venditti, Jeremy G.

206

First estimates of mass concentrations from Eyjafjll over The Netherlands using PCA on  

E-Print Network [OSTI]

First estimates of mass concentrations from Eyjafjöll over The Netherlands using PCA on multi The Netherlands a limit has been proposed of 1 mg m-3. Here, we present preliminary results from Raman lidar measurements made in central Netherlands. A first estimate of the maximum mass loading that occurred over

Graaf, Martin de

207

Funding Opportunity Announcement: Concentrating Solar Power:...  

Broader source: Energy.gov (indexed) [DOE]

Funding Opportunity Announcement: Concentrating Solar Power: Advanced Projects Offering Low LCOE Opportunities Funding Opportunity Announcement: Concentrating Solar Power: Advanced...

208

Modularization and simulation techniques for heat balance-based energy and load calculation  

E-Print Network [OSTI]

the Loads Toolkit research project is to obtain a heat balance based load calculation procedure that

Richard K. Strand

2001-01-01T23:59:59.000Z

209

Load controller and method to enhance effective capacity of a photovotaic power supply using a dynamically determined expected peak loading  

DOE Patents [OSTI]

A load controller and method are provided for maximizing effective capacity of a non-controllable, renewable power supply coupled to a variable electrical load also coupled to a conventional power grid. Effective capacity is enhanced by monitoring power output of the renewable supply and loading, and comparing the loading against the power output and a load adjustment threshold determined from an expected peak loading. A value for a load adjustment parameter is calculated by subtracting the renewable supply output and the load adjustment parameter from the current load. This value is then employed to control the variable load in an amount proportional to the value of the load control parameter when the parameter is within a predefined range. By so controlling the load, the effective capacity of the non-controllable, renewable power supply is increased without any attempt at operational feedback control of the renewable supply. The expected peak loading of the variable load can be dynamically determined within a defined time interval with reference to variations in the variable load.

Perez, Richard (Delmar, NY)

2003-04-01T23:59:59.000Z

210

Seismic considerations in the evaluation of temporary loads  

SciTech Connect (OSTI)

Temporary loads in nuclear power facilities can result from a number of activities including special one time operating conditions, repair and upgrade conditions, and ALARA requirements for operation, inspection and maintenance. Many times evaluation of these loadings includes their consideration in conjunction with other design basis loadings such as normal loads and extreme event loads including earthquake loadings. At times this combination with design basis extreme loads, such as earthquake, results in predicted structural demands which exceed the design basis capacity. Many times a major contributor to this demand prediction is the earthquake loadings. Discussed in this paper are analytical methods, probabilistic considerations, and earthquake experienced based evaluations which can be applied to reduce the earthquake demand for short term temporary loadings.

Adams, T.M. [Stevenson and Associates, Cleveland, OH (United States); Stevenson, J.D.

1996-12-01T23:59:59.000Z

211

Energy 101: Concentrating Solar Power  

ScienceCinema (OSTI)

From towers to dishes to linear mirrors to troughs, concentrating solar power (CSP) technologies reflect and collect solar heat to generate electricity. A single CSP plant can generate enough power for about 90,000 homes. This video explains what CSP is, how it works, and how systems like parabolic troughs produce renewable power. For more information on the Office of Energy Efficiency and Renewable Energy's CSP research, see the Solar Energy Technology Program's Concentrating Solar Power Web page at http://www1.eere.energy.gov/solar/csp_program.html.

None

2013-05-29T23:59:59.000Z

212

Energy 101: Concentrating Solar Power  

SciTech Connect (OSTI)

From towers to dishes to linear mirrors to troughs, concentrating solar power (CSP) technologies reflect and collect solar heat to generate electricity. A single CSP plant can generate enough power for about 90,000 homes. This video explains what CSP is, how it works, and how systems like parabolic troughs produce renewable power. For more information on the Office of Energy Efficiency and Renewable Energy's CSP research, see the Solar Energy Technology Program's Concentrating Solar Power Web page at http://www1.eere.energy.gov/solar/csp_program.html.

None

2010-01-01T23:59:59.000Z

213

Loading and pre-loading processes generate a distinct siRNA population in Tetrahymena  

SciTech Connect (OSTI)

Highlights: •The Tetrahymena Argonaute protein Twi1p binds to ?28–30-nt siRNAs called scnRNAs. •The size of scnRNAs is determined during a pre-loading process. •The 5? uracil bias of scnRNAs is attributed to pre-loading and loading processes. •The thermodynamic asymmetry of scnRNA duplex doesnot affect the guide strand decision. •scnRNAs may be produced non-sequentially from dsRNA substrates by Dicer. -- Abstract: The various properties of small RNAs, such as length, terminal nucleotide, thermodynamic asymmetry and duplex mismatches, can impact their sorting into different Argonaute proteins in diverse eukaryotes. The developmentally regulated 26- to 32-nt siRNAs (scnRNAs) are loaded to the Argonaute protein Twi1p and display a strong bias for uracil at the 5? end. In this study, we used deep sequencing to analyze loaded and unloaded populations of scnRNAs. We show that the size of the scnRNA is determined during a pre-loading process, whereas their 5? uracil bias is attributed to both pre-loading and loading processes. We also demonstrate that scnRNAs have a strong bias for adenine at the third base from the 3? terminus, suggesting that most scnRNAs are direct Dicer products. Furthermore, we show that the thermodynamic asymmetry of the scnRNA duplex does not affect the guide and passenger strand decision. Finally, we show that scnRNAs frequently have templated uracil at the last base without a strong bias for adenine at the second base indicating non-sequential production of scnRNAs from substrates. These findings provide a biochemical basis for the varying attributes of scnRNAs, which should help improve our understanding of the production and turnover of scnRNAs in vivo.

Mochizuki, Kazufumi, E-mail: kazufumi.mochizuki@imba.oeaw.ac.at; Kurth, Henriette M.

2013-07-05T23:59:59.000Z

214

Paper No. 2004-mfb-03 Kelly Page: 1 of 4 Tensile Loading of Model Caisson Foundations for Structures on Sand  

E-Print Network [OSTI]

Paper No. 2004-mfb-03 Kelly Page: 1 of 4 Tensile Loading of Model Caisson Foundations for Structures on Sand R.B. Kelly, B.W. Byrne, G.T. Houlsby and C.M. Martin Department of Engineering) (see Byrne et al, 2002; Byrne et al, 2003; Kelly et al, 2003). This paper concentrates on the tensile

Byrne, Byron

215

Methods for Analyzing Electric Load Shape and its Variability  

SciTech Connect (OSTI)

Current methods of summarizing and analyzing electric load shape are discussed briefly and compared. Simple rules of thumb for graphical display of load shapes are suggested. We propose a set of parameters that quantitatively describe the load shape in many buildings. Using the example of a linear regression model to predict load shape from time and temperature, we show how quantities such as the load?s sensitivity to outdoor temperature, and the effectiveness of demand response (DR), can be quantified. Examples are presented using real building data.

Price, Philip

2010-05-12T23:59:59.000Z

216

ACCELERATED IMPROVEMENT A CONCENTRATED APPROACH  

E-Print Network [OSTI]

ACCELERATED IMPROVEMENT A CONCENTRATED APPROACH FOR CONTINUOUS IMPROVEMENT #12;Accelerated.quality.wisc.edu O F F I C E O F Q U A L I T Y I M P R O V E M E N T Accelerated Improvement This guide to improving resources. You will find helpful information needed to conduct an Accelerated Improvement project

Shapiro, Vadim

217

Physics and Astronomy Geophysics Concentration  

E-Print Network [OSTI]

Physics and Astronomy Geophysics Concentration Strongly recommended courses Credits Term Dept. to Geophysics 3 PHY 3230 Thermal Physics 3 CHE 1101 Introductory Chemistry - I 3 CHE 1110 Introductory Chemistry Laboratory - I 1 GLY 1101 Intro. to Physical Geology 4 GLY 2250 Evolution of the Earth 4 GLY 4705 Adv

Thaxton, Christopher S.

218

Deterministic Josephson Vortex Ratchet with a load  

E-Print Network [OSTI]

We investigate experimentally a deterministic underdamped Josephson vortex ratchet -- a fluxon-particle moving along a Josephson junction in an asymmetric periodic potential. By applying a sinusoidal driving current one can compel the vortex to move in a certain direction, producing average dc voltage across the junction. Being in such a rectification regime we also load the ratchet, i.e., apply an additional dc bias current I_dc (counterforce) which tilts the potential so that the fluxon climbs uphill due to the ratchet effect. The value of the bias current at which the fluxon stops climbing up defines the strength of the ratchet effect and is determined experimentally. This allows us to estimate the loading capability of the ratchet, the output power and efficiency. For the quasi-static regime we present a simple model which delivers simple analytic expressions for the above mentioned figures of merit.

M. Knufinke; K. Ilin; M. Siegel; D. Koelle; R. Kleiner; E. Goldobin

2011-09-29T23:59:59.000Z

219

Atmospheric Mercury Concentrations Near Salmon Falls Creek Reservoir - Phase 1  

SciTech Connect (OSTI)

Elemental and reactive gaseous mercury (EGM/RGM) were measured in ambient air concentrations over a two-week period in July/August 2005 near Salmon Falls Creek Reservoir, a popular fishery located 50 km southwest of Twin Falls, Idaho. A fish consumption advisory for mercury was posted at the reservoir in 2002 by the Idaho Department of Health and Welfare. The air measurements were part of a multi-media (water, sediment, precipitation, air) study initiated by the Idaho Department of Environmental Quality and the U.S. Environmental Protection Agency (EPA) Region 10 to identify potential sources of mercury contamination to the reservoir. The sampling site is located about 150 km northeast of large gold mining operations in Nevada, which are known to emit large amounts of mercury to the atmosphere (est. 2,200 kg/y from EPA 2003 Toxic Release Inventory). The work was co-funded by the Idaho National Laboratory’s Community Assistance Program and has a secondary objective to better understand mercury inputs to the environment near the INL, which lies approximately 230 km to the northeast. Sampling results showed that both EGM and RGM concentrations were significantly elevated (~ 30 – 70%, P<0.05) compared to known regional background concentrations. Elevated short-term RGM concentrations (the primary form that deposits) were likely due to atmospheric oxidation of high EGM concentrations, which suggests that EGM loading from upwind sources could increase Hg deposition in the area. Back-trajectory analyses indicated that elevated EGM and RGM occurred when air parcels came out of north-central and northeastern Nevada. One EGM peak occurred when the air parcels came out of northwestern Utah. Background concentrations occurred when the air was from upwind locations in Idaho (both northwest and northeast). Based on 2003 EPA Toxic Release Inventory data, it is likely that most of the observed peaks were from Nevada gold mine sources. Emissions from known large natural mercury sources in that area cannot account for the observed EGM peaks due to their diffuse source geometry and the large (170 km) transport distance involved. The EGM peak originating from northwestern Utah air may be from three known mercury sources west of Salt Lake City (Kennecott, US Magnesium, Clean Harbors Aragonite) and/or the 1600 MW coal-fired Intermountain Power plant near Delta. However, the relative importance of these short-term peaks for long-term watershed mercury loading (critical factor affecting fish concentrations) is not known, and there is a need to better quantify the annual frequency and magnitude of these different inputs over a longer period of time.

M. L. Abbott

2005-10-01T23:59:59.000Z

220

Electricity pricing for conservation and load shifting  

SciTech Connect (OSTI)

The electricity industry is facing the challenge of increasing costs of reliably meeting demand growth and fully complying with legislative renewable portfolio standards and greenhouse gas reduction targets. However, an electric utility's existing tariffs often don't have rates that increase with consumption volume or vary by time of use, thus not fully exploiting the potential benefits from customer conservation and load shifting. (author)

Orans, Ren; Woo, C.K.; Horii, Brian; Chait, Michele; DeBenedictis, Andrew

2010-04-15T23:59:59.000Z

Note: This page contains sample records for the topic "load three-junction concentrator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Advanced Reactors Transition Program Resource Loaded Schedule  

SciTech Connect (OSTI)

The Advanced Reactors Transition (ART) Resource Loaded Schedule (RLS) provides a cost and schedule baseline for managing the project elements within the ART Program. The Fast Flux Test Facility (FFTF) activities are delineated through the end of FY 2000, assuming continued standby. The Nuclear Energy (NE) Legacies and Plutonium Recycle Test Reactor (PRTR) activities are delineated through the end of the deactivation process. This document reflects the 1 Oct 1999 baseline.

BOWEN, W.W.

1999-11-08T23:59:59.000Z

222

Composition containing aerogel substrate loaded with tritium  

DOE Patents [OSTI]

The invention provides a process for loading an aerogel substrate with tritium and the resultant compositions. According to the process, an aerogel substrate is hydrolyzed so that surface OH groups are formed. The hydrolyzed aerogel is then subjected to tritium exchange employing, for example, a tritium-containing gas, whereby tritium atoms replace H atoms of surface OH groups. OH and/or CH groups of residual alcohol present in the aerogel may also undergo tritium exchange.

Ashley, Carol S. (Albuquerque, NM); Brinker, C. Jeffrey (Albuquerque, NM); Ellefson, Robert E. (Centerville, OH); Gill, John T. (Miamisburg, OH); Reed, Scott (Albuquerque, NM); Walko, Robert J. (Albuquerque, NM)

1992-01-01T23:59:59.000Z

223

Thermal loading considerations for synchrotron radiation mirrors  

SciTech Connect (OSTI)

Grazing incidence mirrors used to focus synchrotron radiation beams through small distant apertures have severe optical requirements. The surface distortion due to heat loading of the first mirror in a bending magnet beam line is of particular concern when a large fraction of the incident beam is absorbed. In this paper we discuss mirror design considerations involved in minimizing the thermal/mechanical loading on vertically deflecting first surface mirrors required for SPEAR synchrotron radiation beam lines. Topics include selection of mirror material and cooling method, the choice of SiC for the substrate, optimization of the thickness, and the design of the mirror holder and cooling mechanism. Results obtained using two-dimensional, finite-element thermal/mechanical distortion analysis are presented for the case of a 6/sup 0/ grazing incidence SiC mirror absorbing up to 260 W at Beam Line VIII on the SPEAR ring. Test descriptions and results are given for the material used to thermally couple this SiC mirror to a water-cooled block. The interface material is limited to applications for which the equivalent normal heat load is less than 20 W/cm/sup 2/.

Holdener, F.R.; Berglin, E.J.; Fuchs, B.A.; Humpal, H.H.; Karpenko, V.P.; Martin, R.W.; Tirsell, K.G.

1986-03-26T23:59:59.000Z

224

64 kW concentrator Photovoltaics Application Test Center. Volume. Final report  

SciTech Connect (OSTI)

Kaman Sciences Corporation has designed a 64 kW Concentrating Photovoltaic Applications Test Center (APTEC). The APTEC employs a combined concentrating photovoltaic array in a total energy system application for load sharing the electric and thermal demands of a large computer center with the interfaced electric and natural gas utility. The photovoltaic array is composed of two-axis tracking heliostats of Fresnel lens concentrating, silicon solar cell modules. The modules are cooled with a fluid which transfers heat to a ground coupled heat sink/storage unit for subsequent use in meeting the computer center's thermal load demand. The combined photovoltaic power system shares basic components - a power conditioning unit, batteries and thermal conditioning equipment - with the electric and natural gas utility service, improving the computer center's operating availability time and displacing a portion of the fossil fuel required to power the computer center with solar energy. The detailed system design is reported.

Jardine, D.M.; Jones, D.W.

1980-06-01T23:59:59.000Z

225

SLUDGE TREATMENT PROJECT COST COMPARISON BETWEEN HYDRAULIC LOADING AND SMALL CANISTER LOADING CONCEPTS  

SciTech Connect (OSTI)

The Sludge Treatment Project (STP) is considering two different concepts for the retrieval, loading, transport and interim storage of the K Basin sludge. The two design concepts under consideration are: (1) Hydraulic Loading Concept - In the hydraulic loading concept, the sludge is retrieved from the Engineered Containers directly into the Sludge Transport and Storage Container (STSC) while located in the STS cask in the modified KW Basin Annex. The sludge is loaded via a series of transfer, settle, decant, and filtration return steps until the STSC sludge transportation limits are met. The STSC is then transported to T Plant and placed in storage arrays in the T Plant canyon cells for interim storage. (2) Small Canister Concept - In the small canister concept, the sludge is transferred from the Engineered Containers (ECs) into a settling vessel. After settling and decanting, the sludge is loaded underwater into small canisters. The small canisters are then transferred to the existing Fuel Transport System (FTS) where they are loaded underwater into the FTS Shielded Transfer Cask (STC). The STC is raised from the basin and placed into the Cask Transfer Overpack (CTO), loaded onto the trailer in the KW Basin Annex for transport to T Plant. At T Plant, the CTO is removed from the transport trailer and placed on the canyon deck. The CTO and STC are opened and the small canisters are removed using the canyon crane and placed into an STSC. The STSC is closed, and placed in storage arrays in the T Plant canyon cells for interim storage. The purpose of the cost estimate is to provide a comparison of the two concepts described.

GEUTHER J; CONRAD EA; RHOADARMER D

2009-08-24T23:59:59.000Z

226

Energy Efficient Geographical Load Balancing via Dynamic Deferral of Workload  

E-Print Network [OSTI]

Energy Efficient Geographical Load Balancing via Dynamic Deferral of Workload Muhammad Abdullah geographical load balancing techniques have been suggested for data centers hosting cloud computation in order to reduce energy cost by exploiting the electricity price differences across regions. However

Gupta, Rajesh

227

Assessing and Reducing Miscellaneous Electric Loads (MELs) in Lodging  

SciTech Connect (OSTI)

Miscellaneous electric loads (MELs) are the loads outside of a building's core functions of heating, ventilating, air conditioning, lighting, and water heating. This report reviews methods to reduce MELs in lodging.

Rauch, Emily M.

2011-09-01T23:59:59.000Z

228

Modeling and Estimating Current Harmonics of Variable Electronic Loads  

E-Print Network [OSTI]

This paper develops a model for relating input current harmonic content to real power consumption for variable electronic loads, specifically for loads' actively controlled inverters energized by an uncontrolled rectification ...

Wichakool, Warit

229

Cooling load differences between radiant and air systems  

E-Print Network [OSTI]

radiant heat transfer for cooling load calculation.heat gain is well recognized by cooling load calculationload calculation approach for radiant systems, Corgnati [17] also tackled the direct radiant heat

Feng, Jingjuan Dove; Schiavon, Stefano; Bauman, Fred

2013-01-01T23:59:59.000Z

230

Load Management and Houston Lighting and Power Co.  

E-Print Network [OSTI]

Defining Load Management as influencing of customer loads in order to shift the time use of electric power and energy, encompasses a broad spectrum of activities at Houston Lighting & Power Company. This paper describes those activities by directing...

Drawe, R. G.; Ramsay, I. M.

1984-01-01T23:59:59.000Z

231

Development of concentrator solar cells  

SciTech Connect (OSTI)

A limited pilot production run on PESC silicon solar cells for use at high concentrations (200 to 400 suns) is summarized. The front contact design of the cells was modified for operation without prismatic covers. The original objective of the contract was to systematically complete a process consolidation phase, in which all the, process improvements developed during the contract would be combined in a pilot production run. This pilot run was going to provide, a basis for estimating cell costs when produced at high throughput. Because of DOE funding limitations, the Photovoltaic Concentrator Initiative is on hold, and Applied Solar`s contract was operated at a low level of effort for most of 1993. The results obtained from the reduced scope pilot run showed the effects of discontinuous process optimization and characterization. However, the run provided valuable insight into the technical areas that can be optimized to achieve the original goals of the contract.

Not Available

1994-08-01T23:59:59.000Z

232

Cylindrical acoustic levitator/concentrator  

DOE Patents [OSTI]

A low-power, inexpensive acoustic apparatus for levitation and/or concentration of aerosols and small liquid/solid samples having particulates up to several millimeters in diameter in air or other fluids is described. It is constructed from a commercially available, hollow cylindrical piezoelectric crystal which has been modified to tune the resonance frequency of the breathing mode resonance of the crystal to that of the interior cavity of the cylinder. When the resonance frequency of the interior cylindrical cavity is matched to the breathing mode resonance of the cylindrical piezoelectric transducer, the acoustic efficiency for establishing a standing wave pattern in the cavity is high. The cylinder does not require accurate alignment of a resonant cavity. Water droplets having diameters greater than 1 mm have been levitated against the force of gravity using; less than 1 W of input electrical power. Concentration of aerosol particles in air is also demonstrated.

Kaduchak, Gregory (Los Alamos, NM); Sinha, Dipen N. (Los Alamos, NM)

2002-01-01T23:59:59.000Z

233

Customer Load Eligibility Guidelines (CLEG), June 26, 2013  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Incidental andor IrrigationPumping, and Commercial Processing Loads on a Single Meter. ... 4 5.2.4. Incidental...

234

ARM - Measurement - Particle number concentration  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc Documentation RUC : XDCResearch Relatedcontent ARMnumber concentration ARM Data Discovery Browse

235

Photovoltaic concentrator module improvements study  

SciTech Connect (OSTI)

This report presents results of a project to design and fabricate an improved photovoltaic concentrator module. Using previous work as a baseline, this study conducted analyses and testing to select major module components and design features. The lens parquet and concentrator solar cell were selected from the highest performing, available components. A single 185X point-focus module was fabricated by the project team and tested at Sandia. Major module characteristics include a 6 by 4 compression-molded acrylic lens parquet (0.737 m{sup 2} area), twenty-four 0.2 ohms-cm, FZ, p-Si solar cells (1.56 cm{sup 2} area) soldered to ceramic substrates and copper heat spreaders, and an aluminized steel housing with corrugated bottom. This project marked the first attempt to use prismatic covers on solar cells in a high-concentration, point-focus application. Cells with 15 percent metallization were obtained, but problems with the fabrication and placement of prismatic covers on these cells lead to the decision not to use covers in the prototype module. Cell assembly fabrication, module fabrication, and module optical design activities are presented here. Test results are also presented for bare cells, cell assemblies, and module. At operating conditions of 981 watts/m{sup 2} DNI and an estimated cell temperature of 65{degrees}C, the module demonstrated an efficiency of 13.9 percent prior to stressed environmental exposure. 12 refs., 56 figs., 7 tabs.

Levy, S.L.; Kerschen, K.A. (Black and Veatch, Kansas City, MO (United States)); Hutchison, G. (Solar Kinetics, Inc., Dallas, TX (United States)); Nowlan, M.J. (Spire Corp., Bedford, MA (United States))

1991-08-01T23:59:59.000Z

236

Reduced Study Load Application Form International Students on Student Visa  

E-Print Network [OSTI]

in a standard load for the following reasons: Continued on next page #12;CRICOS Provider No. 00300K (NTReduced Study Load Application Form International Students on Student Visa CRICOS Provider No. 00300K (NT/VIC) | CRICOS Provider No. 03286A (NSW) Study Load Requirements International students

237

On the Minimum Load Coloring Problem --Extended Abtract--  

E-Print Network [OSTI]

# such that the maximum load, l # := max{r# , b #}, is minimized. In the following we shall skip the term ``maximumOn the Minimum Load Coloring Problem --Extended Abtract-- Nitin Ahuja 1 , Andreas Baltz 2 Abstract. Given a graph G = (V, E) with n vertices, m edges and maximum vertex degree #, the load

Doerr, Benjamin

238

Simultaneous confidence bands in curve prediction applied to load curves  

E-Print Network [OSTI]

Simultaneous confidence bands in curve prediction applied to load curves J.M. Aza¨is1, S. Bercu2, J, load curve. 1 Introduction In curve prediction, one is generally interested in deriving simultaneous this technique in the numerical context of load curve pre- diction: power producers like EDF, the electrical

Boyer, Edmond

239

Numerical Simulation of Wave Loads on Static Offshore Structures  

E-Print Network [OSTI]

Numerical Simulation of Wave Loads on Static Offshore Structures Hrvoje Jasak, Inno Gatin, Vuko Workshop, Cambridge, 30 July 2014 Numerical Simulation of Wave Loads on Static Offshore Structures ­ p. #12 of Wave Loads on Static Offshore Structures ­ p. #12;VOF Free Surface Flow Model Modelling of Free Surface

240

Coupling Wind Generation with Controllable Load and Storage  

E-Print Network [OSTI]

Coupling Wind Generation with Controllable Load and Storage: A Time-Series Application of the Super Electric Energy System #12;Coupling Wind Generation with Controllable Load and Storage: A Time Wind Generation with Controllable Load and Storage: A Time-Series Application of the SuperOPF." (PSERC

Note: This page contains sample records for the topic "load three-junction concentrator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

THERMAL LOADING OF A DIRECT DRIVE TARGET IN  

E-Print Network [OSTI]

optics. A background gas, such as Xe, could reduce the damage on the wall from ion and heat loading fusion micro explosion (~ 10 Hz), ions and heat loads threaten to damage the reactor wall and driver. · The thermal loading of a target (radiation from the chamber wall and convection from the protective gas) may

Raffray, A. René

242

Guide to Dowel LoadTransfer Systems for Jointed Concrete  

E-Print Network [OSTI]

Guide to Dowel LoadTransfer Systems for Jointed Concrete Roadway Pavements TECH BRIEF SEPTEMBER 2011 #12;#12;GUIDE TO DOWEL LOAD TRANSFER SYSTEMS FOR JOINTED CONCRETE ROADWAY PAVEMENTS i Technical and Subtitle Guide to Dowel Load Transfer Systems for Jointed Concrete Roadway Pavements 5. Report Date

243

AIAA980057 RELATING TURBULENCE TO WIND TURBINE BLADE LOADS  

E-Print Network [OSTI]

AIAA­98­0057 RELATING TURBULENCE TO WIND TURBINE BLADE LOADS: PARAMETRIC STUDY WITH MULTIPLE that is most useful in estimating fatigue loads on wind turbine blades. The histograms of rainflow counted turbulence measures---can be used to estimate fatigue loads on wind turbine blades. We first de­ scribe

Sweetman, Bert

244

Load Alleviation on Wind Turbine Blades using Variable Airfoil Geometry  

E-Print Network [OSTI]

Load Alleviation on Wind Turbine Blades using Variable Airfoil Geometry Peter Bjřrn Andersen, Mac Loads, Trailing Edge Flaps, PID control, Signal Noise. 1 Introduction Wind turbine blades are subject to 40% when signal noise is added to the control. Keywords: Wind Turbine, Load Alleviation, Fatigue

245

Design Loads for Wind Turbines using the Environmental Contour Method  

E-Print Network [OSTI]

Design Loads for Wind Turbines using the Environmental Contour Method Korn Saranyasoontorn, TX 78712 When interest is in establishing ultimate design loads for wind turbines such that a service). The parametric conditional load distri- butions require extensive turbine response simulations over the entire

Manuel, Lance

246

Extreme Loads for an Offshore Wind Turbine using Statistical  

E-Print Network [OSTI]

Extreme Loads for an Offshore Wind Turbine using Statistical Extrapolation from Limited Field Data,itiscommontoeithercarry out extensive simulation studies or undertake a field measurement campaign. At the Blyth offshore wind here is to estimate extreme loads for an offshore wind turbine for which the environmental and load

Manuel, Lance

247

PARAMETRIC MODELS FOR ESTIMATING WIND TURBINE FATIGUE LOADS FOR DESIGN  

E-Print Network [OSTI]

loads. #12;2 INTRODUCTION Design constraints for wind turbine structures fall into either extreme load1 PARAMETRIC MODELS FOR ESTIMATING WIND TURBINE FATIGUE LOADS FOR DESIGN Lance Manuel1 Paul S, TX 78712 2 Sandia National Laboratories, Wind Energy Technology Department, Albuquerque, NM 87185

Sweetman, Bert

248

Analysis of rabbit intervertebral disc physiology based on water metabolism. II. Changes in normal intervertebral discs under axial vibratory load  

SciTech Connect (OSTI)

Metabolic changes induced by axial vibratory load to the spine were investigated based on water metabolism in normal intervertebral discs of rabbits with or without pentobarbital anesthesia. Tritiated water concentration in the intervertebral discs of unanesthetized rabbits was reduced remarkably by axial vibration for 30 minutes using the vibration machine developed for this study. Repeated vibratory load for 18 and 42 hours duration showed the recovery of /sup 3/H/sub 2/O concentration of the intervertebral disc without anesthesia. Computer simulation suggested a reduction of blood flow surrounding the intervertebral disc following the vibration stress. However, no reduction of the /sup 3/H/sub 2/O concentration in the intervertebral disc was noted under anesthesia. Emotional stress cannot be excluded as a factor in water metabolism in the intervertebral disc.

Hirano, N.; Tsuji, H.; Ohshima, H.; Kitano, S.; Itoh, T.; Sano, A.

1988-11-01T23:59:59.000Z

249

Experiential Component Approval Form Concentration in Nanotechnology  

E-Print Network [OSTI]

Experiential Component Approval Form Concentration in Nanotechnology Return completed form to ENG Plan to complete the experiential component as a requirement for the concentration in Nanotechnology to complete the experiential component for the Nanotechnology Concentration by: Research Experience in Lab

Goldberg, Bennett

250

A microfabricated dielectrophoretic micro-organism concentrator  

E-Print Network [OSTI]

This project focuses on the development of a micro-organism concentrator. Pathogen detection, particularly MEMS based detection, is often limited by sample concentration. The proposed concentrator will interface with a ...

Muller, Rikky, 1980-

2004-01-01T23:59:59.000Z

251

The Load Distribution Problem in a Processor Ring Francis C.M. Lau  

E-Print Network [OSTI]

the load balancing procedure into the following phases: load measurement, calculation of load averageThe Load Distribution Problem in a Processor Ring Francis C.M. Lau Department of Computer Science picture of the system load and the average load, the load distribution problem is to find a suitable

Lau, Francis C.M.

252

44-BWR WASTE PACKAGE LOADING CURVE EVALUATION  

SciTech Connect (OSTI)

The objective of this calculation is to evaluate the required minimum burnup as a function of initial boiling water reactor (BWR) assembly enrichment that would permit loading of spent nuclear fuel into the 44 BWR waste package configuration as provided in Attachment IV. This calculation is an application of the methodology presented in ''Disposal Criticality Analysis Methodology Topical Report'' (YMP 2003). The scope of this calculation covers a range of enrichments from 0 through 5.0 weight percent (wt%) U-235, and a burnup range of 0 through 40 GWd/MTU. This activity supports the validation of the use of burnup credit for commercial spent nuclear fuel applications. The intended use of these results will be in establishing BWR waste package configuration loading specifications. Limitations of this evaluation are as follows: (1) The results are based on burnup credit for actinides and selected fission products as proposed in YMP (2003, Table 3-1) and referred to as the ''Principal Isotopes''. Any change to the isotope listing will have a direct impact on the results of this report. (2) The results of 100 percent of the current BWR projected waste stream being able to be disposed of in the 44-BWR waste package with Ni-Gd Alloy absorber plates is contingent upon the referenced waste stream being sufficiently similar to the waste stream received for disposal. (3) The results are based on 1.5 wt% Gd in the Ni-Gd Alloy material and having no tuff inside the waste package. If the Gd loading is reduced or a process to introduce tuff inside the waste package is defined, then this report would need to be reevaluated based on the alternative materials.

J.M. Scaglione

2004-08-25T23:59:59.000Z

253

Gross crack initiation and propagation in brittle thin solid and annular disks subjected to impact loading  

SciTech Connect (OSTI)

This paper derives from a study of grinding wheel break-up behavior due to impact. The impact fracture characteristics of circular disks of plaster of Paris with a concentric central hole were studied experimentally for three types of loading: (a) when the disks were suspended freely and loaded intensely at one point on their circumference by an explosive detonator; (b) when the disks were allowed to fall under gravity from a certain height on to a rigid base; and (c) when a disk, resting on a rigid base, was struck by a flat ended rigid body which was dropped on to it from a certain height. Quasi-static flattening tests on the disks were also carried out. The paper describes a theoretical investigation into the stress analysis of disks under impact, classifies the relevant damage sustained by them and attempts to unify the ''gross'' impact fracture patterns which arise in different modes of dynamic loading. The extent of local flattening of the quasi-statically loaded disks before fracture, is also reported. Good correlation between the theory and experimental results is obtained, especially for rings of diameter ratio (D /SUB i/ /D/sub 0/) of around 0.5.

Johnson, W.; Bai, Y.L.; Ghosh, S.K.

1984-04-01T23:59:59.000Z

254

Dynamics of Helium-Loaded Grain Boundaries under Shear Deformation in ?-Fe  

SciTech Connect (OSTI)

The defects produced in collision cascades will interact with microstructural features in materials, such as GBs and dislocations. The coupled motion of GBs under stress has been widely observed in simulations and experiments. Two symmetric tilt GBs with a common <110> tilt axis (?3 and ?11) in bcc iron are used to investigate the coupled motion of GBs under shear deformation. Also, we have explored the effect of self-interstitial atoms (SIAs) loading on the GB motion, with different concentrations of interstitials randomly inserted around the GB plane. The simulation results show that the interstitial loading reduces the critical stress of the GB coupled motion for the ?3 GB. Furthermore, the interstitials and vacancies are inserted randomly at the GB plane and at a distance of 1 nm away from the GB plane, respectively, to understand the self-healing mechanism of GBs under stress. The behavior of the defect-loaded GBs depends on the GB structure. The loaded interstitials in the ?3 GB easily form <111> interstitial clusters that do not move along with the GB. The vacancies in the ?3 GB impede the GB motion. However, the interstitials move along with the ?11 GB and annihilate with vacancies when the GB moves into the vacancy-rich region, leading to the self-healing and damage recovery of the ?11 GB.

Gao, Fei; Yang, Li; Heinisch, Howard L.; Kurtz, Richard J.

2014-03-30T23:59:59.000Z

255

Rotordynamic coefficients for a load-between-pad, flexible-pivot tilting pad bearing at high loads  

E-Print Network [OSTI]

The dynamic and static performance of a flexure-pivot tilting pad bearing is presented at a load between pad configuration for various load and speed combinations. A similar work performed on the same bearing at lower loads ranging from 0-1 MPa (0...

Hensley, John Eric

2006-10-30T23:59:59.000Z

256

Performance of Geogrid Reinforced Ballast under Dynamic Loading  

E-Print Network [OSTI]

string pot versus dynamic loading at 1100 psi (9 psi tie bearing pressure) 37 4.1.3 East string pot versus dynamic loading at 2500 psi (21 psi tie bearing pressure) 38 4.1.4 East string pot versus dynamic loading at 3500 psi (31 psi tie bearing pressure...) 39 4.1.5 East string pot versus dynamic loading at 4500 psi (38 psi tie bearing pressure) 41 4.1.6 East string pot versus dynamic loading at 4500 psi (soaked) (40 psi tie bearing pressure) 43 4.2 Unreinforced test 45 4.2.1 West string pot 45 4...

Jowkar, Milad

2011-12-31T23:59:59.000Z

257

Concentration Averaging | Department of Energy  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power Systems EngineeringDepartmentSmart Grid RFI:Fresno U.S.Energy Order issuedConcentration

258

Impact of self-attraction and loading on the annual cycle in sea level  

E-Print Network [OSTI]

load and inferred ocean load following the SAL adjustment.following analysis, we assume that the Earth’s response to the changing continental loads

Tamisiea, M. E; Hill, E. M; Ponte, R. M; Davis, J. L; Velicogna, I.; Vinogradova, N. T

2010-01-01T23:59:59.000Z

259

Load Response Fundamentally Matches Power System Reliability Requirements  

SciTech Connect (OSTI)

Responsive load is the most underutilized reliability resource available to the power system. Loads are frequently barred from providing the highest value and most critical reliability services; regulation and spinning reserve. Advances in communications and control technology now make it possible for some loads to provide both of these services. The limited storage incorporated in some loads better matches their response capabilities to the fast reliability-service markets than to the hourly energy markets. Responsive loads are frequently significantly faster and more accurate than generators, increasing power system reliability. Incorporating fast load response into microgrids further extends the reliability response capabilities that can be offered to the interconnected power system. The paper discusses the desired reliability responses, why this matches some loads' capabilities, what the advantages are for the power system, implications for communications and monitoring requirements, and how this resource can be exploited.

Kirby, Brendan J [ORNL] [ORNL

2007-01-01T23:59:59.000Z

260

Modeling of highly loaded fluorescent lamps  

SciTech Connect (OSTI)

Numerical modeling of the positive column of fluorescent lamps under conditions of high current density are of current interest, particularly in view of recent developments in electrodeless lamps. Current models tend to overestimate radiation output, and consequently the maintenance electric field in these discharges. Under highly loaded conditions, mercury-rare gas fluorescent lamps exhibit strong mercury depletion on axis (cataphoresis), and an understanding of resonance radiation transport under these conditions is therefore vital to the development of models with a predictive capability. The authors have explored the effect of radial cataphoresis on resonance radiation trapping for situations in which the radiation transport is dominated by foreign gas broadening, Doppler broadening, or resonance collisional broadening of the spectral line. Several different production rates per unit volume of resonance (excited) atoms have also been studied. It is advantageous in many cases to parameterize the trapped decay rate in terms of the total number of ground state atoms in the positive column independent of their radial distribution. The results of this work have been included in a numerical model of the positive column and the predicted influence on discharge parameters will be presented for cases of interest to highly loaded lamps.

Lister, G.G.; Lawler, J.E.; Curry, J.J.

1999-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "load three-junction concentrator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Thermal loading study for FY 1995  

SciTech Connect (OSTI)

This report provides the results of sensitivity analyses designed to assist the test planners in focusing their in-situ measurements on parameters that appear to be important to waste isolation. Additionally, the study provides a preliminary assessment of the feasibility of certain thermal management options. A decision on thermal loading is a critical part of the scientific and engineering basis for evaluating regulatory compliance of the potential repository for waste isolation. To show, with reasonable assurance, that the natural and engineered barriers will perform adequately under expected repository conditions (thermally perturbed) will require an integrated approach based on thermal testing (laboratory, and in-situ), natural analog observations, and analytic modeling. The Office of Civilian Radioactive Waste Management needed input to assist in the planning of the thermal testing program. Additionally, designers required information on the viability of various thermal management concepts. An approximately 18-month Thermal Loading Study was conducted from March, 1994 until September 30, 1995 to address these issues. This report documents the findings of that study. 89 refs., 71 figs., 33 tabs.

NONE

1996-01-31T23:59:59.000Z

262

SAPHIRE 8 Volume 7 - Data Loading  

SciTech Connect (OSTI)

The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) is a software application developed for performing a complete probabilistic risk assessment (PRA) using a personal computer. SAPHIRE Version 8 is funded by the U.S. Nuclear Regulatory Commission and developed by the Idaho National Laboratory. This report is intended to assist the user to enter PRA data into the SAPHIRE program using the built-in MAR-D ASCII-text file data transfer process. Towards this end, a small sample database is constructed and utilized for demonstration. Where applicable, the discussion includes how the data processes for loading the sample database relate to the actual processes used to load a larger PRA models. The procedures described herein were developed for use with SAPHIRE Version 8. The guidance specified in this document will allow a user to have sufficient knowledge to both understand the data format used by SAPHIRE and to carry out the transfer of data between different PRA projects.

K. J. Kvarfordt; S. T. Wood; C. L. Smith; S. R. Prescott

2011-03-01T23:59:59.000Z

263

A new generation of load sharing algorithms: the semi-adaptive load sharing algorithm  

E-Print Network [OSTI]

: Wael, Omar, Tamer, Ashraf and Hazem, who were always there for me. Your support and comfort have given me the strength to go through all the bad times. TABLE OF CONTENTS CHAPTER Page INTRODUCTION A. What is Load Sharing? B. Thesis Outline 2 4...

Morsy, Hazem Kamal

1997-01-01T23:59:59.000Z

264

Extension of load follow capability of a PWR reactor by optimal control  

SciTech Connect (OSTI)

The problem of extending that part of the fuel life cycle during which a reactor is capable of sustaining load-follow operation is formulated as an optimal control problem. A two-node model representation of pressurized water reactor dynamics is used, leading to a set of non-linear ordinary differential equations. Differential Dynamic Programming is used to solve directly the resulting nonlinear optimization problem and obtain the trajectories of soluble boron concentration and control rod insertion. Results of computations performed for a reference reactor are presented, showing how the optimal control policy stretches the capability of the reactor to follow an average daily load curve towards the end of the fuel life cycle.

Winokur, M.; Tepper, L.

1984-04-01T23:59:59.000Z

265

Concentrating Solar Power: Technology Overview  

SciTech Connect (OSTI)

Concentrating Solar Power (CSP) has the potential to contribute significantly to the generation of electricity by renewable energy resources in the U.S.. Thermal storage can extend the duty cycle of CSP beyond daytime hours to early evening where the value of electricity is often the highest. The potential solar resource for the southwest U.S. is identified, along with the need to add power lines to bring the power to consumers. CSP plants in the U.S. and abroad are described. The CSP cost of electricity at the busbar is discussed. With current incentives, CSP is approaching competiveness with conventional gas-fired systems during peak-demand hours when the price of electricity is the highest. It is projected that a mature CSP industry of over 4 GWe will be able to reduce the energy cost by about 50%, and that U.S. capacity could be 120 GW by 2050.

Mehos, M.

2008-01-01T23:59:59.000Z

266

Relative importance of multiple factors on terrestrial loading of DOC to Arctic river networks  

SciTech Connect (OSTI)

Terrestrial carbon dynamics influence the contribution of dissolved organic carbon (DOC) to river networks in addition to controlling carbon fluxes between the land surface and the atmosphere. In this study, we use a biogeochemical process model to simulate the lateral transfer of DOC from land to the Arctic Ocean via riverine transport. We estimate that the pan-arctic watershed has contributed, on average, 32 Tg C/yr of DOC to the Arctic Ocean over the 20th century with most coming from the extensive area of boreal deciduous needle-leaved forests and forested wetlands in Eurasian watersheds. We also estimate that the rate of terrestrial DOC loading has been increasing by 0.037 Tg C/yr2 over the 20th century primarily as a result of increases in air temperatures and precipitation. These increases have been partially compensated by decreases in terrestrial DOC loading caused by wildfires. Other environmental factors (CO2 fertilization, ozone pollution, atmospheric nitrogen deposition, timber harvest, agriculture) are estimated to have relatively small effects on terrestrial DOC loading to arctic rivers. The effects of the various environmental factors on terrestrial carbon dynamics have both compensated and enhanced concurrent effects on hydrology to influence terrestrial DOC loading. Future increases in riverine DOC concentrations and export may occur from warming-induced increases in terrestrial DOC production associated with enhanced microbial metabolism and the exposure of additional organic matter from permafrost degradation along with decreases in water yield associated with warming-induced increases in evapotranspiration. Improvements in simulating terrestrial DOC loading to pan-arctic rivers in the future will require better information on the spatial distribution of precipitation and its temporal trends, carbon dynamics of larch-dominated ecosystems in eastern Siberia, and the role of industrial organic effluents on carbon budgets of rivers in western Russia.

Kicklighter, David W. [Ecosystem Center, The] [Ecosystem Center, The; Hayes, Daniel J [ORNL] [ORNL; Mcclelland, James W [University of Texas] [University of Texas; Peterson, Bruce [Marine Biological Laboratory] [Marine Biological Laboratory; Mcguire, David [University of Alaska] [University of Alaska; Melillo, Jerry [Marine Biological Laboratory] [Marine Biological Laboratory

2014-01-01T23:59:59.000Z

267

Active load control techniques for wind turbines.  

SciTech Connect (OSTI)

This report provides an overview on the current state of wind turbine control and introduces a number of active techniques that could be potentially used for control of wind turbine blades. The focus is on research regarding active flow control (AFC) as it applies to wind turbine performance and loads. The techniques and concepts described here are often described as 'smart structures' or 'smart rotor control'. This field is rapidly growing and there are numerous concepts currently being investigated around the world; some concepts already are focused on the wind energy industry and others are intended for use in other fields, but have the potential for wind turbine control. An AFC system can be broken into three categories: controls and sensors, actuators and devices, and the flow phenomena. This report focuses on the research involved with the actuators and devices and the generated flow phenomena caused by each device.

van Dam, C.P. (University of California, Davis, CA); Berg, Dale E.; Johnson, Scott J. (University of California, Davis, CA)

2008-07-01T23:59:59.000Z

268

Lubrication for high load duplex bearings  

SciTech Connect (OSTI)

Three ES and H-compatible lubricants (Environment, Safety and Health) for high load duplex bearing applications were evaluated and compared against trichlorotrifluoroethane (Freon) deposition of low molecular weight polytetrafluoroethylene (PTFE) bearing lubricant extracted from Vydax{trademark}. Vydax is a product manufactured by DuPont consisting of various molecular weights of PTFE suspended in trichlorotrifluoroethane (Freon) which is an ozone-depleting solvent. Bearings with Supercritical CO{sub 2} deposition of PTFE extracted from Vydax AR/IPA, bearings with titanium carbide coated balls, and bearings with diamond-like carbon races and retainers were evaluated. Bearings with Supercritical CO{sub 2} deposition of PTFE from Vydax AR/IPA performed as well as bearings with Freon deposition of PTFE from Freon-based Vydax.

Steinhoff, R.G.

1997-08-01T23:59:59.000Z

269

514 ASHRAE Transactions: Symposia Design cooling load calculation methods are, by the  

E-Print Network [OSTI]

Handbook--Fundamentals (ASHRAE 1997) and the Cooling and Heating Load Calculation Manual (Mc514 ASHRAE Transactions: Symposia ABSTRACT Design cooling load calculation methods are Load Calculation Methods (942-RP)" are also given. INTRODUCTION Design cooling load calculation

270

Siting Utility-Scale Concentrating Solar Power Projects  

SciTech Connect (OSTI)

In 2002, Congress asked the U.S. Department of Energy to develop and scope out an initiative to fulfill the goal of having 1,000 megawatts (MW) of new parabolic trough, power tower, and dish engine solar capacity supplying the southwestern United States. In this paper, we present a review of the solar resource for Arizona, California, Nevada, and New Mexico. These four states have the greatest number of ''premium'' solar sites in the country and each has a renewable portfolio standard (RPS). We present information on the generation potential of the solar resources in these states. We also present regions within New Mexico that may be ideally suited for developing large-scale concentrating solar power (CSP) plants because of their proximity to load and their access to unconstrained transmission.

Mehos, M.; Owens, B.

2005-01-01T23:59:59.000Z

271

Modeling The Potential For Thermal Concentrating Solar Power Technologies  

SciTech Connect (OSTI)

In this paper we explore the tradeoffs between thermal storage capacity, cost, and other system parameters in order to examine possible evolutionary pathways for thermal Concen-trating Solar Power (CSP) technologies. A representation of CSP performance that is suit-able for incorporation into economic modeling tools is developed. We find that, as the fraction of electricity supplied by CSP technologies grows, the application of thermal CSP technologies might progress from current hybrid plants, to plants with a modest amount of thermal storage, and potentially even to plants with sufficient thermal storage to provide base load generation capacity. The representation of CSP cost and performance developed here was implemented in the ObjECTS MiniCAM long-term integrated assessment model. Datasets for global solar resource characteristics as applied to CSP technology were also developed. The regional and global potential of thermal CSP technologies is examined.

Zhang, Yabei; Smith, Steven J.; Kyle, G. Page; Stackhouse, Jr., Paul W.

2010-10-25T23:59:59.000Z

272

Estimating market potential for reducing customer peak loads through photovoltaics  

SciTech Connect (OSTI)

Past studies have quantified photovoltaics` (PV) peak load matching capability on a utility-wide scale. The purpose of this paper is to estimate the number of utility subloads (e.g., customers, substations) whose peak loads are well matched with solar availability. A simple tool based on the utility scale load-PV match is developed to estimate the market size of customer scale PV applications with high load-PV matches. Illustrative examples of customer owned PV economics are also provided. The authors show that (1) the market size of high load matching PV applications on the subload scale is significant even within utility systems whose load requirements are not particularly well matched with PV output; and (2) the cost of PV as a peak shaving resource for utility customers is approaching competitive levels.

Bryan, J. [Citizens Advisory Panel, Central Islip, NY (United States); Perez, R. [Univ. of New York, Albany, NY (United States). Atmospheric Sciences Research Center

1996-11-01T23:59:59.000Z

273

Cementitious Stabilization of Mixed Wastes with High Salt Loadings  

SciTech Connect (OSTI)

Salt loadings approaching 50 wt % were tolerated in cementitious waste forms that still met leach and strength criteria, addressing a Technology Deficiency of low salt loadings previously identified by the Mixed Waste Focus Area. A statistical design quantified the effect of different stabilizing ingredients and salt loading on performance at lower loadings, allowing selection of the more effective ingredients for studying the higher salt loadings. In general, the final waste form needed to consist of 25 wt % of the dry stabilizing ingredients to meet the criteria used and 25 wt % water to form a workable paste, leaving 50 wt % for waste solids. The salt loading depends on the salt content of the waste solids but could be as high as 50 wt % if all the waste solids are salt.

Spence, R.D.; Burgess, M.W.; Fedorov, V.V.; Downing, D.J.

1999-04-01T23:59:59.000Z

274

Production of fullerenes using concentrated solar flux  

DOE Patents [OSTI]

A method of producing soot containing high amounts of fullerenes comprising: providing a primary concentrator capable of impingement of a concentrated beam of sunlight onto a carbon source to cause vaporization of carbon and subsequent formation of fullerenes, or providing a solar furnace having a primary concentrator with a focal point that concentrates a solar beam of sunlight; providing a reflective secondary concentrator having an entrance aperture and an exit aperture at the focal point of the solar furnace; providing a carbon source at the exit aperture of the secondary concentrator; supplying an inert gas over the carbon source to keep the secondary concentrator free from vaporized carbon; and impinging a concentrated beam of sunlight from the secondary concentrator on the carbon source to vaporize the carbon source into a soot containing high amounts of fullerenes.

Fields, Clark L. (Greeley, CO); Pitts, John Roland (Lakewood, CO); King, David E. (Lakewood, CO); Hale, Mary Jane (Golden, CO); Bingham, Carl E. (Denver, CO); Lewandowski, Allan A. (Evergreen, CO)

2000-01-01T23:59:59.000Z

275

Strategy Guideline: Accurate Heating and Cooling Load Calculations  

SciTech Connect (OSTI)

This guide presents the key criteria required to create accurate heating and cooling load calculations and offers examples of the implications when inaccurate adjustments are applied to the HVAC design process. The guide shows, through realistic examples, how various defaults and arbitrary safety factors can lead to significant increases in the load estimate. Emphasis is placed on the risks incurred from inaccurate adjustments or ignoring critical inputs of the load calculation.

Burdick, A.

2011-06-01T23:59:59.000Z

276

Industrial Load Shaping: A Utility Strategy to Deal with Competition  

E-Print Network [OSTI]

INDUSTRIAL LOAD SHAPING: A UTILITY STRATEGY TO DEAL WITH COMPETITION DONALD BULES BULES AND ASSOCIATES SAN FRANCISCO, ABSTRACT In recent years competition from various sources such as cogeneration and bypass has led many utilities... to refocus attention on their large industrial customers. Industrial load shaping is a customized program involving cost-effective process modifications and operational changes which result in a restructuring of the electric load profile of individual...

Bules, D.

277

Extracting Operating Modes from Building Electrical Load Data: Preprint  

SciTech Connect (OSTI)

Empirical techniques for characterizing electrical energy use now play a key role in reducing electricity consumption, particularly miscellaneous electrical loads, in buildings. Identifying device operating modes (mode extraction) creates a better understanding of both device and system behaviors. Using clustering to extract operating modes from electrical load data can provide valuable insights into device behavior and identify opportunities for energy savings. We present a fast and effective heuristic clustering method to identify and extract operating modes in electrical load data.

Frank, S.; Polese, L. G.; Rader, E.; Sheppy, M.; Smith, J.

2012-01-01T23:59:59.000Z

278

Concentrating Solar Power (Fact Sheet)  

SciTech Connect (OSTI)

Concentrating Solar Power (CSP) offers a utility-scale, firm, dispatchable renewable energy option that can help meet the nation's goal of making solar energy cost competitive with other energy sources by the end of the decade. The DOE SunShot Initiative is a collaborative national initiative to make solar energy technologies cost-competitive with other forms of energy by reducing the cost of solar energy systems by about 75% by the end of the decade. Reducing the total installed cost for utility-scale solar electricity to roughly 6 cents per kilowatt hour without subsidies will result in rapid, large-scale adoption of solar electricity across the United States. Reaching this goal will re-establish American technological leadership, improve the nation's energy security, and strengthen U.S. economic competitiveness in the global clean energy race. SunShot will work to bring down the full cost of solar - including the costs of solar cells and installation by focusing on four main pillars: (1) Technologies for solar cells and arrays that convert sunlight to energy; (2) Electronics that optimize the performance of the installation; (3) Improvements in the efficiency of solar manufacturing processes; and (4) Installation, design, and permitting for solar energy systems.

Not Available

2011-10-01T23:59:59.000Z

279

Planar photovoltaic solar concentrator module  

DOE Patents [OSTI]

A planar photovoltaic concentrator module for producing an electrical signal from incident solar radiation includes an electrically insulating housing having a front wall, an opposing back wall and a hollow interior. A solar cell having electrical terminals is positioned within the interior of the housing. A planar conductor is connected with a terminal of the solar cell of the same polarity. A lens forming the front wall of the housing is operable to direct solar radiation incident to the lens into the interior of the housing. A refractive optical element in contact with the solar cell and facing the lens receives the solar radiation directed into the interior of the housing by the lens and directs the solar radiation to the solar cell to cause the solar cell to generate an electrical signal. An electrically conductive planar member is positioned in the housing to rest on the housing back wall in supporting relation with the solar cell terminal of opposite polarity. The planar member is operable to dissipate heat radiated by the solar cell as the solar cell generates an electrical signal and further forms a solar cell conductor connected with the solar cell terminal to permit the electrical signal generated by the solar cell to be measured between the planar member and the conductor. 5 figs.

Chiang, C.J.

1992-12-01T23:59:59.000Z

280

Planar photovoltaic solar concentrator module  

DOE Patents [OSTI]

A planar photovoltaic concentrator module for producing an electrical signal from incident solar radiation includes an electrically insulating housing having a front wall, an opposing back wall and a hollow interior. A solar cell having electrical terminals is positioned within the interior of the housing. A planar conductor is connected with a terminal of the solar cell of the same polarity. A lens forming the front wall of the housing is operable to direct solar radiation incident to the lens into the interior of the housing. A refractive optical element in contact with the solar cell and facing the lens receives the solar radiation directed into the interior of the housing by the lens and directs the solar radiation to the solar cell to cause the solar cell to generate an electrical signal. An electrically conductive planar member is positioned in the housing to rest on the housing back wall in supporting relation with the solar cell terminal of opposite polarity. The planar member is operable to dissipate heat radiated by the solar cell as the solar cell generates an electrical signal and further forms a solar cell conductor connected with the solar cell terminal to permit the electrical signal generated by the solar cell to be measured between the planar member and the conductor.

Chiang, Clement J. (New Brunswick, NJ)

1992-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "load three-junction concentrator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Modeling the Effect of Fuel Ethanol Concentration on Cylinder Pressure Evolution in Direct-Injection Flex-Fuel Engines  

E-Print Network [OSTI]

Modeling the Effect of Fuel Ethanol Concentration on Cylinder Pressure Evolution in Direct the fuel vaporization pro- cess for ethanol-gasoline fuel blends and the associated charge cooling effect experimental cylinder pressure for different gasoline-ethanol blends and various speeds and loads on a 2.0 L

Stefanopoulou, Anna

282

Notes 04. Static load performance of plain journal bearings  

E-Print Network [OSTI]

The long and short bearing models. Pressure field and fluid film forces on short length journal bearings. Equilibrium condition, load capacity and the Sommerfeld number....

San Andres, Luis

2010-01-01T23:59:59.000Z

283

Technical Assistance to ISO's and Grid Operators For Loads Providing...  

Broader source: Energy.gov (indexed) [DOE]

Ancillary Services: Review of International Experience Increasing Renewable Energy with Hydrogen Storage and Fuel Cell Technologies 2012 Load as a Resource Program Peer Review...

284

activated carbon load: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

response of phenolic resin and its carbon-nanotube composites to shock wave loading Materials Science Websites Summary: Dynamic response of phenolic resin and its carbon-nanotube...

285

activated carbon loaded: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

response of phenolic resin and its carbon-nanotube composites to shock wave loading Materials Science Websites Summary: Dynamic response of phenolic resin and its carbon-nanotube...

286

Load Expansion of Stoichiometric HCCI Using Spark Assist and...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

of Stoichiometric HCCI Using Spark Assist and Hydraulic Valve Actuation Load Expansion of Stoichiometric HCCI Using Spark Assist and Hydraulic Valve Actuation Presentation given at...

287

Averaged equations for Josephson junction series arrays with LRC load  

E-Print Network [OSTI]

We derive the averaged equations describing a series array of Josephson junctions shunted by a parallel inductor-resistor-capacitor load. We assume that the junctions have negligable capacitance ($\\beta = 0$), and derive averaged equations which turn out to be completely tractable: in particular the stability of both in-phase and splay states depends on a single parameter, $\\del$. We find an explicit expression for $\\delta$ in terms of the load parameters and the bias current. We recover (and refine) a common claim found in the technical literature, that the in-phase state is stable for inductive loads and unstable for capacitive loads.

Kurt Wiesenfeld; James W. Swift

1994-08-26T23:59:59.000Z

288

Commercial and Residential Hourly Load Profiles for all TMY3...  

Open Energy Info (EERE)

hourly load profile data for 16 commercial building types (based off the DOE commercial reference building models) and residential buildings (based off the Building America House...

289

alkohilimgi load lhiajalisemaks: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

are dynamically adjusted. Taking into account the speed at which loads vary and the latency of the underlying network, we specify conditions under which the algorithm is...

290

alkoholimgi load lhiajalisemaks: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

are dynamically adjusted. Taking into account the speed at which loads vary and the latency of the underlying network, we specify conditions under which the algorithm is...

291

HVAC Loads in High-Performance Homes (Presentation)  

SciTech Connect (OSTI)

This presentation was delivered at the ASHRAE 2010 Annual Summer Conference on June 27, 2010, and addresses humidity and AC loads in energy efficient houses.

Christensen, D.; Fang, X.; Winkler, J.

2010-06-27T23:59:59.000Z

292

Retrofitting unreinforced concrete masonry to resist tornado loading  

E-Print Network [OSTI]

Advances in structural design and building materials have significantly increased the performance of many structures under the extreme loading conditions associated with natural disasters such as earthquakes. However, ...

Dorshorst, Evan G. (Evan Gregory)

2013-01-01T23:59:59.000Z

293

A mixed integer programming approach to reduce fuel load ...  

E-Print Network [OSTI]

Feb 12, 2015 ... A mixed integer programming approach to reduce fuel load accumulation for prescribed burn planning. Ramya Rachmawati(ramya.rachmawati ...

Ramya Rachmawati

2015-02-12T23:59:59.000Z

294

Used Nuclear Fuel Loading and Structural Performance Under Normal...  

Energy Savers [EERE]

Used Nuclear Fuel Loading and Structural Performance Under Normal Conditions of Transport - Demonstration of Approach and Results of Used Fuel Performance Characterization Used...

295

Characterization of Dynamic Loads on Solar Modules with Respect...  

Broader source: Energy.gov (indexed) [DOE]

78 CHARACTERIZATION OF DYNAMIC LOADS ON SOLAR MODULES WITH RESPECT TO FRACTURE OF SOLAR CELLS Sascha Dietrich, Matthias Pander, Martin Sander, Matthias Ebert & Fraunhofer - Center...

296

California Customer Load Reductions during the Electricity Crisis...  

Open Energy Info (EERE)

Reductions during the Electricity Crisis: Did They Help to Keep the Lights On? Jump to: navigation, search Tool Summary LAUNCH TOOL Name: California Customer Load Reductions during...

297

Development of an Accelerated Ash-Loading Protocol for Diesel...  

Broader source: Energy.gov (indexed) [DOE]

Accelerated Ash-Loading Protocol for Diesel Particulate Filters Bruce G. Bunting and Todd J. Toops Oak Ridge National Laboratory Adam Youngquist and Ke Nguyen University of...

298

A three phase load flow algorithm for Shipboard Power Systems  

E-Print Network [OSTI]

. . . . . . . . . . . . . . . . . . . , . . . . . . . . . . . 3, 5 Network Representation 3. 6 Component Modeling. 3. 7 Integration of Methodology and Component Modeling . . . 3. 8 Chapter Summary. IV Load Flow Algorithm. . 4. 1 Introduction. 4. 2 Load Flow Algorithm. 4. 3 Application of Load Flow... Algorithm. . 4. 4 Summary of Load Flow Algorithm. 4. 5 Chapter Summary. . nl V1 vn 1X 1 3 5 5 8 15 16 16 18 23 26 27 50 53 54 54 54 69 79 79 CHAPTER V RESULTS AND CONCLUSIONS . . 5. 1 Introduction . . 5. 2 IEEE 37 Bus Radial...

Medina-Calder?on, M?onica M

2003-01-01T23:59:59.000Z

299

advanced load alleviation: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

paradox of the pulsar wind nebula. Maxim Lyutikov 2002-02-19 89 A Technique to Utilize Smart Meter Load Information for Adapting Overcurrent Protection for Radial Distribution...

300

Load Expansion with Diesel/Gasoline RCCI for Improved Engine...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

with DieselGasoline RCCI for Improved Engine Efficiency and Emissions Load Expansion with DieselGasoline RCCI for Improved Engine Efficiency and Emissions This poster will...

Note: This page contains sample records for the topic "load three-junction concentrator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Repository Reference Disposal Concepts and Thermal Load Management...  

Broader source: Energy.gov (indexed) [DOE]

Thermal Load Management Analysis A disposal concept consists of three parts: waste inventory (7 waste types examined), geologic setting (e.g., clayshale, salt, crystalline,...

302

Improved Load Plan Design Through Integer Programming Based ...  

E-Print Network [OSTI]

The fundamental building block in load planning is a direct trailer, or a direct. ... of shipment and trailer dispatching; (2) integrated consideration of the movement ...

2011-12-21T23:59:59.000Z

303

Loads Providing Ancillary Services: Review of International Experience...  

Broader source: Energy.gov (indexed) [DOE]

Trading and Transmission Arrangement BUL Balancing Up Loads DSR Demand Side Response CERTS Consortium for Electric Reliability Technology Solutions EEX European...

304

air conditioning load: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

J.; Deying, L. 2006-01-01 2 Aggregated Modeling and Control of Air Conditioning Loads for Demand Response Computer Technologies and Information Sciences Websites Summary: 1...

305

active load management: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Load Management Programs CATEE Conference October, 2012 Agenda Outline I. General Demand Response Definition II. General Demand Response Program Rules III. CenterPoint...

306

air conditioning loads: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Websites Summary: 1 Aggregated Modeling and Control of Air Conditioning Loads for Demand Response Wei Zhang, Member, IEEE Abstract--Demand response is playing an...

307

building load data | OpenEI Community  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentrating SolarElectric Coop,SaveWhiskey Flats GeothermalElectric Coop Home Home

308

building load | OpenEI Community  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentrating SolarElectric Coop,SaveWhiskey Flats GeothermalElectric Coop Home Home

309

commercial load | OpenEI Community  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentrating SolarElectric Coop,SaveWhiskey Flats GeothermalElectric Coop Home7 August,

310

electric load data | OpenEI Community  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentrating SolarElectric Coop,SaveWhiskey Flats GeothermalElectric Coop

311

load data | OpenEI Community  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentrating SolarElectric Coop,SaveWhiskey Flatshydro Home Water Powerlaunch HomelegislationData

312

load profile | OpenEI Community  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentrating SolarElectric Coop,SaveWhiskey Flatshydro Home Water Powerlaunch

313

Commercial equipment loads: End-Use Load and Consumer Assessment Program (ELCAP)  

SciTech Connect (OSTI)

The Office of Energy Resources of the Bonneville Power Administration is generally responsible for the agency's power and conservation resource planning. As associated responsibility which supports a variety of office functions is the analysis of historical trends in and determinants of energy consumption. The Office of Energy Resources' End-Use Research Section operates a comprehensive data collection program to provide pertinent information to support demand-side planning, load forecasting, and demand-side program development and delivery. Part of this on-going program is known as the End-Use Load and Consumer Assessment Program (ELCAP), an effort designed to collect electricity usage data through direct monitoring of end-use loads in buildings. This program is conducted for Bonneville by the Pacific Northwest Laboratory. This report provides detailed information on electricity consumption of miscellaneous equipment from the commercial portion of ELCAP. Miscellaneous equipment includes all commercial end-uses except heating, ventilating, air conditioning, and central lighting systems. Some examples of end-uses covered in this report are office equipment, computers, task lighting, refrigeration, and food preparation. Electricity consumption estimates, in kilowatt-hours per square food per year, are provided for each end-use by building type. The following types of buildings are covered: office, retail, restaurant, grocery, warehouse, school, university, and hotel/motel. 6 refs., 35 figs., 12 tabs.

Pratt, R.G.; Williamson, M.A.; Richman, E.E.; Miller, N.E.

1990-07-01T23:59:59.000Z

314

Summary of Dissolved Concentration Limits  

SciTech Connect (OSTI)

According to the Technical Work Plan titled Technical Work Plan for Waste Form Degradation Process Model Report for SR (CRWMS M&O 2000a), the purpose of this study is to perform abstractions on solubility limits of radioactive elements based on the process-level information and thermodynamic databases provided by Natural Environment Program Operations (NEPO) and Waste Package Operations (WPO). The scope of this analysis is to produce solubility limits as functions, distributions, or constants for all transported radioactive elements identified by the Performance Assessment Operations (PAO) radioisotope screening. Results from an expert elicitation for solubility limits of most radioactive elements were used in the previous Total System Performance Assessments (TSPAs). However, the elicitation conducted in 1993 does not meet the criteria set forth by the U.S. Nuclear Regulatory Commission (NRC) due to lack of documentation and traceability (Kotra et al. 1996, Section 3). Therefore, at the Waste Form Abstraction Workshop held on February 2-4, 1999, at Albuquerque, New Mexico, the Yucca Mountain Site Characterization Project (YMP) decided to develop geochemical models to study solubility for the proposed Monitored Geologic Repository. WPO/NEPO is to develop process-level solubility models, including review and compilation of relevant thermodynamic data. PAO's responsibility is to perform abstractions based on the process models and chemical conditions and to produce solubility distributions or response surfaces applicable to the proposed repository. The results of this analysis and conceptual model will feed the performance assessment for Total System Performance Assessment--Site Recommendation (TSPA-SR) and Total System Performance Assessment--License Application (TSPA-LA), and to the Waste Form Degradation Process Model Report section on concentration limits.

Yueting Chen

2001-06-11T23:59:59.000Z

315

New GaInP/GaAs/GaInAs, Triple-Bandgap, Tandem Solar Cell for High-Efficiency Terrestrial Concentrator Systems  

SciTech Connect (OSTI)

GaInP/GaAs/GaInAs three-junction cells are grown in an inverted configuration on GaAs, allowing high quality growth of the lattice matched GaInP and GaAs layers before a grade is used for the 1-eV GaInAs layer. Using this approach an efficiency of 37.9% was demonstrated.

Kurtz, S.; Wanlass, M.; Kramer, C.; Young, M.; Geisz, J.; Ward, S.; Duda, A.; Moriarty, T.; Carapella, J.; Ahrenkiel, P.; Emery. K.; Jones, K.; Romero, M.; Kibbler, A.; Olson, J.; Friedman, D.; McMahon, W.; Ptak, A.

2005-11-01T23:59:59.000Z

316

Modelling the settling of suspended sediments for concentrations close to the gelling concentration  

E-Print Network [OSTI]

Modelling the settling of suspended sediments for concentrations close to the gelling concentration the sedimentation phase. In the case of cohesive sediments, the estimation of the gelling concentration, although and consolidation behaviour for concentrations close to the gelling concentration. Key words: sedimentation

Paris-Sud XI, Université de

317

Modeling of concentrating solar thermoelectric generators  

E-Print Network [OSTI]

The conversion of solar power into electricity is dominated by non-concentrating photovoltaics and concentrating solar thermal systems. Recently, it has been shown that solar thermoelectric generators (STEGs) are a viable ...

Ren, Zhifeng

318

Report of the US Nuclear Regulatory Commission Piping Review Committee. Volume 4. Evaluation of other loads and load combinations  

SciTech Connect (OSTI)

Six topical areas were covered by the Task Group on Other Dynamic Loads and Load Combinations as described below: Event Combinations - dealing with the potential simultaneous occurrence of earthquakes, pipe ruptures, and water hammer events in the piping design basis; Response Combinations - dealing with multiply supported piping with independent inputs, the sequence of combinations between spacial and modal components of response, and the treatment of high frequency modes in combination with low frequency modal responses; Stress Limits/Dynamic Allowables - dealing with inelastic allowables for piping and strain rate effects; Water Hammer Loadings - dealing with code and design specifications for these loadings and procedures for identifying potential water hammer that could affect safety; Relief Valve Opening and Closing Loads - dealing with the adequacy of analytical tools for predicting the effects of these events and, in addition, with estimating effective cycles for fatigue evaluations; and Piping Vibration Loads - dealing with evaluation procedures for estimating other than seismic vibratory loads, the need to consider reciprocating and rotary equipment vibratory loads, and high frequency vibratory loads. NRC staff recommendations or regulatory changes and additional study appear in this report.

Not Available

1984-12-01T23:59:59.000Z

319

Concentration in Mathematics (2014-2015)  

E-Print Network [OSTI]

Concentration in Mathematics (2014-2015) What Can You Do With Math? Concentration in mathematics is an excellent preparation for a career in either pure or applied mathematics, in academia or in industry on mathematical methods, a math concentration can provide an invaluable background for many different careers

Wolfe, Patrick J.

320

Lithium Loaded Glass Fiber Neutron Detector Tests  

SciTech Connect (OSTI)

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world and, thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. Reported here are the results of tests of the lithium-loaded glass fibers option. This testing measured the neutron detection efficiency and gamma ray rejection capabilities of a small system manufactured by Nucsafe (Oak Ridge, TN).

Ely, James H.; Erikson, Luke E.; Kouzes, Richard T.; Lintereur, Azaree T.; Stromswold, David C.

2009-11-12T23:59:59.000Z

Note: This page contains sample records for the topic "load three-junction concentrator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Investigation of optimal reactor control for a load-following PWR  

SciTech Connect (OSTI)

Characteristics of optimal load-follow control of PWR plants are investigated in this study. A simple system model that describes main features of physical processes in the system was developed. The system model includes core neutronics with all the spatial dependent feedback effects, Xe-I dynamics, core thermal balances, primary-loop thermal balances, and steam-generator dynamic responses to turbine load changes. An optimal control problem that describes power-level control and power-distribution control problem together and considers all the important system operation limits as hard inquality constraints was formulated. The full-length control rod bank positions, part-length control rod positions, and boron concentration changes were modeled as control variables and turbine load variations were used as the forcing variable. Because modern PWR operating policy is to leave the part-length rods uninserted, the part-length rods were not used as a control variable in the optimal control calculations. The optimal control problem was converted to unconstrained nonlinear optimization problem by using the discretization approximation and the penalty function technique. The converted problem was solved by the nonlinear Gauss-Newton method which showed superior performance over all of the other tested optimization methods.

Yim, M.S.

1987-01-01T23:59:59.000Z

322

Studies on the stripping of cerium from the loaded tbp-kerosene solution  

SciTech Connect (OSTI)

The reductive stripping of Ce(IV) from the loaded organic phase (30% TBP in kerosene) was investigated, using two stripping agents, EDTA and H{sub 2}O{sub 2}, in nitric acid. The results are compared to determine the optimum conditions for the reduction of Ce(IV) in the organic phase to Ce(III) in the aqueous phase. For each of the two stripping agents, the effect of different parameters affecting the reduction process was investigated: stripping-agent concentration, nitric acid concentration, phase ratio, shaking time, and temperature. The results are compared and discussed in terms of the conditions required for maximum reductive stripping of Ce(IV). (authors)

Rizk, S.E.; Abdel Rahman, N.; Daoud, J.A.; Aly, H.F. [Hot Laboratories Centre, Atomic Energy Authority, Cairo (Egypt)

2008-07-01T23:59:59.000Z

323

REVIEW OF METHODS TO REDUCE URBAN STORMWATER LOADS  

E-Print Network [OSTI]

, the implementation of Best Management Practices (BMPs) capable of controlling or removing Hg and PCBs from urban for preliminary prioritization of best management practices (BMPs) (Section 5). Section 3: Describes areas and storm water, measurements of loads in stormwater, and demonstration that either loads

324

Incentivizing Advanced Load Scheduling in Smart Homes , and David Irwin  

E-Print Network [OSTI]

Incentivizing Advanced Load Scheduling in Smart Homes Ye Xu , and David Irwin , and Prashant Shenoy Department of Electrical and Computer Engineering School of Computer Science University of Massachusetts Amherst ABSTRACT In recent years, researchers have proposed numerous advanced load scheduling algorithms

Massachusetts at Amherst, University of

325

Fetch Halting on Critical Load Misses Nikil Mehta,  

E-Print Network [OSTI]

Fetch Halting on Critical Load Misses Nikil Mehta, Brian Singer, R. Iris Bahar Division, such as loads that miss to main memory and floating point arithmetic operations, are primarily responsible to characterize critical instructions, our approach com- bines software profiling and hardware monitoring

DeHon, André

326

Power load forecasting Organization: Huizhou Electric Power, P. R. China  

E-Print Network [OSTI]

Power load forecasting Organization: Huizhou Electric Power, P. R. China Presenter: Zhifeng Hao can be divided into load forecasting and electrical consumption predicting according to forecasting in generators macroeconomic control, power exchange plan and so on. And the prediction is from one day to seven

327

Performance Analysis of Photovoltaic Cell with Dynamic PHEV Loads  

E-Print Network [OSTI]

Performance Analysis of Photovoltaic Cell with Dynamic PHEV Loads F. R. Islam, H. R. Pota, M. S. Rahman and M. S. Ali Abstract--This paper presents the dynamics of photovoltaic (PV) cell with Plug for charging PHEVs with PV cell where PHEVs load are modelled based on third order battery model. System

Pota, Himanshu Roy

328

IMPROVEMENTS TO THE RADIANT TIME SERIES METHOD COOLING LOAD CALCULATION  

E-Print Network [OSTI]

IMPROVEMENTS TO THE RADIANT TIME SERIES METHOD COOLING LOAD CALCULATION PROCEDURE By BEREKET, Australia 1998 Submitted to the Faculty of the Graduate College of the Oklahoma State University in partial TO THE RADIANT TIME SERIES METHOD COOLING LOAD CALCULATION PROCEDURE Dissertation Approved: Dr. Jeffrey D

329

SURF 2005; final report Load Balancing Strategies for  

E-Print Network [OSTI]

SURF 2005; final report Load Balancing Strategies for Parallel SAMR Algorithms A Study of partial differential equations are important in many areas of science and technology. Only adaptive mesh in a load-balanced manner is even more difficult than for unstructured mesh refinement techniques. Therefore

330

VEHICLE TRACKING USING MOBILE WIRELESS SENSOR NETWORKS DURING DYNAMIC LOAD  

E-Print Network [OSTI]

and put into service, engineers lack cost-effective methods for measuring the actual loads imposedVEHICLE TRACKING USING MOBILE WIRELESS SENSOR NETWORKS DURING DYNAMIC LOAD TESTING OF HIGHWAY in the understanding of vehicle-bridge interactions. Direct measurement of the complex coupling that naturally exists

Lynch, Jerome P.

331

Combining daylighting, personal controls, and load shedding offers  

E-Print Network [OSTI]

Combining daylighting, personal controls, and load shedding offers enormous potential for reducing lighting system to respond to available daylight and demand response control · Allows building occupants--Consider the improved cost-effectiveness of wireless dimming to promote daylighting controls and load- shedding

332

Detection of Periodic Beacon Loads in Electrical Distribution Substation Data  

SciTech Connect (OSTI)

This research explores methods for identifying a whether a load is sending a signal to the utility SCADA system. Such a system can identify whether various loads are signialing using existing SCADA infrastructure, that is, without added, high cost communications infrastructure.

Hammerstrom, Donald J.; Guttromson, Ross T.; Lu, Ning; Boyd, Paul A.; Trudnowski, Daniel; Chassin, David P.; Bonebrake, Christopher A.; Shaw, James M.

2006-05-31T23:59:59.000Z

333

Empirical Characterization and Modeling of Electrical Loads in Smart Homes  

E-Print Network [OSTI]

in data analysis: i) generating device-accurate synthetic traces of building electricity usage, and ii) filtering out loads that generate rapid and random power variations in building electricity data. Keywords--ElectricalEmpirical Characterization and Modeling of Electrical Loads in Smart Homes Sean Barker, Sandeep

Shenoy, Prashant

334

A Practical Approach to Dynamic Load Balancing Jerrell Watts  

E-Print Network [OSTI]

Transfer Vector Calculation ¢ ¡ ¢ £ ¤ £ ¢ ¡ ¢ ¢ ¡ ¢ ¡ ¢ ¡ ¢ £ ¤ £ ¢ ¤ £ ¢ 8 2.3.1 Heat DiffusionA Practical Approach to Dynamic Load Balancing Jerrell Watts Scalable Concurrent Programming versions of the node adaption and movement routines which were used by the load balancing code; he also

335

Temperature Aware Microprocessor Floorplanning Considering Application Dependent Power Load  

E-Print Network [OSTI]

heat diffusion model taking into account the ap- plication dependent power load for thermal analysis is calculated to evaluate each new floorplan, which is time-consuming. [7] proposed a simple deterministic heatTemperature Aware Microprocessor Floorplanning Considering Application Dependent Power Load Chun

He, Lei

336

Infrared Temperature Sensing of Mechanically Loaded Specimens: Thermal Analysis  

E-Print Network [OSTI]

, not the instantaneous effect of heating within a single loading cycle. KEY WORDS--Infrared, temperature measurement, meInfrared Temperature Sensing of Mechanically Loaded Specimens: Thermal Analysis by Y. Rabin and D. Rittel ABSTRACT--Infrared temperature-sensing techniques have the major advantages of virtually

Rabin, Yoed

337

actinides loading optimization: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

actinides loading optimization First Page Previous Page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Next Page Last Page Topic Index 1 Building load control...

338

Ris-R-1111(EN) Ultimate Loading of Wind Turbines  

E-Print Network [OSTI]

Risø-R-1111(EN) Ultimate Loading of Wind Turbines Gunner Chr. Larsen, Knut Ronold, Hans E analysis as well as a wind turbine reliability study. In the wind climate analysis, the distribution to analyse wind turbine components with respect to failure in ultimate loading, and in addition to establish

339

Cone Penetrometer Load Cell Temperature and Radiation Testing Results  

SciTech Connect (OSTI)

This report summarizes testing activities performed at the Pacific Northwest National Laboratory to verify the cone penetrometer load cell can withstand the tank conditions present in 241-AN-101 and 241-AN-106. The tests demonstrated the load cell device will operate under the elevated temperature and radiation levels expected to be encountered during tank farm deployment of the device.

Follett, Jordan R.

2013-08-28T23:59:59.000Z

340

Load Alleviation through Adaptive Trailing Edge Control Surfaces: ADAPWING Overview  

E-Print Network [OSTI]

to investigate the potential of using adaptive trailing edge geometry on wind turbine blades as load alleviation field experienced by wind turbine blades is turbulent which causes fluctuating loads during nor- mal for the wind turbine industry if the alleviation systems do not add considerable extra cost. Recent work has

Note: This page contains sample records for the topic "load three-junction concentrator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

residential load | OpenEI Community  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentrating SolarElectric Coop,SaveWhiskey Flatshydro Home Water Homerequest for propsals HomeData

342

Load Component Database of Household Appliances and Small Office Equipment  

SciTech Connect (OSTI)

This paper discusses the development of a load component database for household appliances and office equipment. To develop more accurate load models at both transmission and distribution level, a better understanding on the individual behaviors of home appliances and office equipment under power system voltage and frequency variations becomes more and more critical. Bonneville Power Administration (BPA) has begun a series of voltage and frequency tests against home appliances and office equipments since 2005. Since 2006, Researchers at Pacific Northwest National Laboratory has collaborated with BPA personnel and developed a load component database based on these appliance testing results to facilitate the load model validation work for the Western Electricity Coordinating Council (WECC). In this paper, the testing procedure and testing results are first presented. The load model parameters are then derived and grouped. Recommendations are given for aggregating the individual appliance models to feeder level, the models of which are used for distribution and transmission level studies.

Lu, Ning; Xie, YuLong; Huang, Zhenyu; Puyleart, Francis; Yang, Steve

2008-07-24T23:59:59.000Z

343

Behavior of plate trunnions subjected to shear loads  

SciTech Connect (OSTI)

The use of fabricated trunnions in heavy lift installation of offshore and marine structures is becoming widespread. This paper presents the results of a parametric study, with systematic variation of relevant geometric parameters, on the elasto-plastic responses of plate trunnions subjected to shear loads from the sling eyes. Two distinctive failure modes, associated with main plate dominated and shear plate/trunnion pipe dominated responses are identified and the corresponding results summarized. A proportional limit load, P{sub yl}, is defined for each specimen based on its load-displacement response. It is observed that a plate trunnion possesses significant reserve strength beyond its limit load and that current industry practice, which considers the shear plate only to transfer the total sling load into the main plate, is overly conservative.

Choo, Y.S.; Padmanaban, K.; Shanmugam, N.E.; Liew, J.Y.R. [National Univ. of Singapore (Singapore). Faculty of Engineering

1995-12-31T23:59:59.000Z

344

Recovery Act: Advanced Load Identification and Management for Buildings  

SciTech Connect (OSTI)

In response to the U.S. Department of Energy (DoE)’s goal of achieving market ready, net-zero energy residential and commercial buildings by 2020 and 2025, Eaton partnered with the Department of Energy’s National Renewable Energy Laboratory (NREL) and Georgia Institute of Technology to develop an intelligent load identification and management technology enabled by a novel “smart power strip” to provide critical intelligence and information to improve the capability and functionality of building load analysis and building power management systems. Buildings account for 41% of the energy consumption in the United States, significantly more than either transportation or industrial. Within the building sector, plug loads account for a significant portion of energy consumption. Plug load consumes 15-20% of building energy on average. As building managers implement aggressive energy conservation measures, the proportion of plug load energy can increase to as much as 50% of building energy leaving plug loads as the largest remaining single source of energy consumption. This project focused on addressing plug-in load control and management to further improve building energy efficiency accomplished through effective load identification. The execution of the project falls into the following three major aspects. 1) An intelligent load modeling, identification and prediction technology was developed to automatically determine the type, energy consumption, power quality, operation status and performance status of plug-in loads, using electric waveforms at a power outlet level. This project demonstrated the effectiveness of the developed technology through a large set of plug-in loads measurements and testing. 2) A novel “Smart Power Strip (SPS) / Receptacle” prototype was developed to act as a vehicle to demonstrate the feasibility of load identification technology as a low-cost, embedded solution. 3) Market environment for plug-in load control and management solutions, in particular, advanced power strips (APSs) was studied. The project evaluated the market potential for Smart Power Strips (SPSs) with load identification and the likely impact of a load identification feature on APS adoption and effectiveness. The project also identified other success factors required for widespread APS adoption and market acceptance. Even though the developed technology is applicable for both residential and commercial buildings, this project is focused on effective plug-in load control and management for commercial buildings, accomplished through effective load identification. The project has completed Smart Receptacle (SR) prototype development with integration of Load ID, Control/Management, WiFi communication, and Web Service. Twenty SR units were built, tested, and demonstrated in the Eaton lab; eight SR units were tested in the National Renewable Energy Lab (NREL) for one-month of field testing. Load ID algorithm testing for extended load sets was conducted within the Eaton facility and at local university campuses. This report is to summarize the major achievements, activities, and outcomes under the execution of the project.

Yang, Yi; Casey, Patrick; Du, Liang; He, Dawei

2014-02-12T23:59:59.000Z

345

Static Heat Loads in the LHC Arc Cryostats: Final Assessment  

E-Print Network [OSTI]

This note presents the final assessment of the static heat loads in the LHC arc cryostats, using different experimental methods during the first commissioning period in 2007. This assessment further develops and completes previous estimates made during the commissioning of sector 7_8 [1]. The estimate of the helium inventory, a prerequisite for the heat load calculation, is also presented. Heat loads to the cold mass are evaluated from the internal energy balance during natural as well as powered warm-ups of the helium baths in different subsector. The helium inventory is calculated from the internal energy balance during powered warm-ups and matched with previous assessments. Furthermore, heat loads to the thermal shield are estimated from the non-isothermal cooling of the supercritical helium in line E. The comparison of measured heat loads with previous estimates and with budgeted values is then presented, while their correlation with some important parameters like insulation vacuum pressure and some heat ...

Parma, V

2010-01-01T23:59:59.000Z

346

Design-Load Basis for LANL Structures, Systems, and Components  

SciTech Connect (OSTI)

This document supports the recommendations in the Los Alamos National Laboratory (LANL) Engineering Standard Manual (ESM), Chapter 5--Structural providing the basis for the loads, analysis procedures, and codes to be used in the ESM. It also provides the justification for eliminating the loads to be considered in design, and evidence that the design basis loads are appropriate and consistent with the graded approach required by the Department of Energy (DOE) Code of Federal Regulation Nuclear Safety Management, 10, Part 830. This document focuses on (1) the primary and secondary natural phenomena hazards listed in DOE-G-420.1-2, Appendix C, (2) additional loads not related to natural phenomena hazards, and (3) the design loads on structures during construction.

I. Cuesta

2004-09-01T23:59:59.000Z

347

Impact load mitigation in sandwich beams using local resonators  

E-Print Network [OSTI]

Dynamic response of sandwich beams with resonators embedded in the cores subjected to impact loads is studied. Using finite element models the effectiveness of various local resonator frequencies under a given impact load is compared to the behavior of an equivalent mass beam. It is shown that addition of appropriately chosen local resonators into the sandwich beam is an effective method of improving its flexural bending behavior under impact loads. The effect of a given local resonance frequency under different impact load durations is also studied. It is demonstrated that the choice of appropriate local resonance frequency depends on the impact duration. Further, by performing transverse impact experiments, the finite element models are verified and the advantage of using internal resonators under impact loading conditions is demonstrated.

Sharma, B

2015-01-01T23:59:59.000Z

348

A Note on On-line Load Balancing for Related Machines  

E-Print Network [OSTI]

and the load of entire schedule s as follows: load(s;i) = 1 vi X s(j)=i pj; Load(s) = maxi load(s;i) It is easy by the machines with speed larger than v if the load cannot exceed .) The following observation is immediateA Note on On-line Load Balancing for Related Machines Piotr Berman Marek Karpinski y Abstract We

Eckmiller, Rolf

349

Short-Term Load Forecasting This paper discusses the state of the art in short-term load fore-  

E-Print Network [OSTI]

spectrum of time intervals. In therange of seconds, when load variationsare small and random, the automatic by a number of generation control functions such as hydro scheduling, unit commitment, hydro-ther- mal present, functions such as fuel, hydro, and maintenance scheduling are performed to ensure that the load

Gross, George

350

Shock initiation studies on high concentration hydrogen peroxide  

SciTech Connect (OSTI)

Concentrated hydrogen peroxide (H{sub 2}O{sub 2}) has been known to detonate for many years. However, because of its reactivity and the difficulty in handling and confining it, along with the large critical diameter, few studies providing basic information about the initiation and detonation properties have been published. We are conducting a study to understand and quantify the initiation and detonation properties of highly concentrated H{sub 2}O{sub 2} using a gas-driven two-stage gun to produce well defined shock inputs. Multiple magnetic gauges are used to make in-situ measurements of the growth of reaction and subsequent detonation in the liquid. These experiments are designed to be one-dimensional to eliminate any difficulties that might be encountered with large critical diameters. Because of the concern of the reactivity of the H{sub 2}O{sub 2} with the confining materials, a remote loading system has been developed. The gun is pressurized, then the cell is filled and the experiment shot within less than three minutes. TV cameras are attached to the target so the cell filling can be monitored. Several experiments have been completed on {approx}98 wt % H{sub 2}O{sub 2}/H{sub 2}O mixtures; initiation has been observed in some experiments that shows homogeneous shock initiation behavior. The initial shock pressurizes and heats the mixture. After an induction time, a thermal explosion type reaction produces an evolving reactive wave that strengthens and eventually overdrives the first wave producing a detonation. From these measurements, we have determined unreacted Hugoniot information, times (distances) to detonation (Pop-plot points) that indicate low sensitivity, and detonation velocities of high concentration H{sub 2}O{sub 2}/H{sub 2}O solutions that agree with earlier estimates.

Sheffield, Stephen A [Los Alamos National Laboratory; Dattelbaum, Dana M [Los Alamos National Laboratory; Stahl, David B [Los Alamos National Laboratory; Gibson, L. Lee [Los Alamos National Laboratory; Bartram, Brian D. [Los Alamos National Laboratory

2009-01-01T23:59:59.000Z

351

Seismic Loading for FAST: May 2011 - August 2011  

SciTech Connect (OSTI)

As more wind farms are constructed in seismically active regions, earthquake loading increases in prominence for design and analysis of wind turbines. Early investigation of seismic load tended to simplify the rotor and nacelle as a lumped mass on top of the turbine tower. This simplification allowed the use of techniques developed for conventional civil structures, such as buildings, to be easily applied to wind turbines. However, interest is shifting to more detailed models that consider loads for turbine components other than the tower. These improved models offer three key capabilities in consideration of base shaking for turbines: 1) The inclusion of aerodynamics and turbine control; 2) The ability to consider component loads other than just tower loads; and 3) An improved representation of turbine response in higher modes by reducing modeling simplifications. Both experimental and numerical investigations have shown that, especially for large modern turbines, it is important to consider interaction between earthquake input, aerodynamics, and operational loads. These investigations further show that consideration of higher mode activity may be necessary in the analysis of the seismic response of turbines. Since the FAST code is already capable of considering these factors, modifications were developed that allow simulation of base shaking. This approach allows consideration of this additional load source within a framework, the FAST code that is already familiar to many researchers and practitioners.

Asareh, M. A.; Prowell, I.

2012-08-01T23:59:59.000Z

352

Assessment of existing studies of wind loading on solar collectors  

SciTech Connect (OSTI)

In developing solar collectors, wind loading is the major structural design consideration. Wind loading investigations have focused on establishing safe bounds for steady state loading and verifying rational but initial and conservative design approaches for the various solar collector concepts. As such, the effort has been very successful, and has contributed greatly to both the recognition and qualitative understanding of many of the physical phenomena involved. Loading coefficients corresponding to mean wind velocities have been derived in these prior studies to measure the expected structural loading on the various solar collectors. Current design and testing procedures for wind loading are discussed. The test results corresponding to numerous wind tests on heliostats, parabolic troughs, parabolic dishes, and field mounted photovoltaic arrays are discussed and the applicability of the findings across the various technologies is assessed. One of the most significant consistencies in the data from all the technologies is the apparent benefit provided by fences and field shielding. Taken in toto, these data show that load reductions of three or possibly more seem feasible, though a more thorough understanding of the phenomena involved must be attained before this benefit can be realized. It is recommended that the required understanding be developed to take advantage of this benefit and that field tests be conducted to correlate with both analyses and tests.

Murphy, L. M.

1981-02-01T23:59:59.000Z

353

Molecular mechanisms of hydrogen loaded B-hydroquinone clathrate  

SciTech Connect (OSTI)

Molecular dynamics simulations are used to investigate the molecular interactions of hydrogen loaded beta-hydroquinone clathrate. It is found that at lower temperatures, higher loadings are more stable, whereas, at higher temperatures, lower loadings are more stable. This trend can be understood based on the interactions in the system. For loadings greater than one, the repulsive forces between the guest molecules shove each other towards the attractive forces between the guest and host molecules leading to a stabilized minimum energy configuration at low temperatures. At higher temperatures greater displacements take the system away from the shallow energy minimum and the trend reverses. The asymmetries of the clathrate cage structure are due to the presence of the attractive forces at loadings greater than one that lead to confined states. The nature of the cavity structure is nearly spherical for a loading of one, leads to preferential occupation near the hydroxyl ring crowns of the cavity with a loading of two, and at higher loadings, leads to occupation of the interstitial sites (the hydroxyl rings) between cages by a single H2 molecule with the remaining molecules occupying the equatorial plane of the cavity. At higher temperatures, the cavity is more uniformly occupied for all loadings, where the occupation of the interstitial positions of the cavities leads to facile diffusion. ACKNOWLEDGEMENT This work was partially supported by NIDO (Japan), LDRD (PNNL), EERE U.S. Department of Energy, and by OBES, U.S. DOE. The Pacific Northwest National Laboratory is operated by Battelle for the U.S. Department of Energy

Daschbach, John L.; Chang, Tsun-Mei; Corrales, Louis R.; Dang, Liem X.; McGrail, B. Peter

2006-09-07T23:59:59.000Z

354

Loads Providing Ancillary Services: Review of International Experience  

SciTech Connect (OSTI)

In this study, we examine the arrangements for and experiences of end-use loads providing ancillary services (AS) in five electricity markets: Australia, the United Kingdom (UK), the Nordic market, and the ERCOT and PJM markets in the United States. Our objective in undertaking this review of international experience was to identify specific approaches or market designs that have enabled customer loads to effectively deliver various ancillary services (AS) products. We hope that this report will contribute to the ongoing discussion in the U.S. and elsewhere regarding what institutional and technical developments are needed to ensure that customer loads can meaningfully participate in all wholesale electricity markets.

Heffner, Grayson; Goldman, Charles; Kintner-Meyer, Michael

2007-05-01T23:59:59.000Z

355

Center for Ecological Management of Military Lands 1 Loading Data from Mixed Data  

E-Print Network [OSTI]

, for example, plot 1 will have an additional file marked as 301. Follow the procedures below to load the data/PRGMS/HHFILES directory. Load these files first following the procedures for loading handheld files. 5) After the files of the handheld files to this directory. Load these files following the procedures for loading handheld files. #12

356

The Load Distribution Problem in a Ring of Processors Francis C.M. Lau \\Lambda  

E-Print Network [OSTI]

into the following phases: load measurement, calculation of load average, generation of load distribution scheduleThe Load Distribution Problem in a Ring of Processors Francis C.M. Lau \\Lambda Department of Computer Science The University of Hong Kong March 1998 Abstract Given a global picture of the system load

Lau, Francis C.M.

357

Load capacity and rupture displacement in viscoelastic fiber bundles Theocharis Baxevanis1,  

E-Print Network [OSTI]

for this critical load is given. For stress levels below the critical value, the system suffers only partial failureLoad capacity and rupture displacement in viscoelastic fiber bundles Theocharis Baxevanis1 loading, assuming global load sharing GLS for the redistribution of load following fiber failure. We

Katsaounis, Theodoros D.

358

Numerical simulation of ice-induced loads on ships and comparison with field measurements  

E-Print Network [OSTI]

Numerical simulation of ice-induced loads on ships and comparison with field measurements Biao Su Department of Marine Technology, NTNU May 28, 2013 #12;Motivation Local ice load Global ice load Ship's performance · Ice-hull interaction · Local ice load · Global ice load · Ship's performance #12;Outline

Nřrvĺg, Kjetil

359

Sandia National Laboratories: Concentrating Solar Power  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Solar Power Technical Management Position On July 12, 2012, in Concentrating Solar Power, Energy, Facilities, Job Listing, National Solar Thermal Test Facility, News,...

360

Sandia National Laboratories: Concentrating Solar Power  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Safety and Health Go Green Initiative On December 19, 2012, in Concentrating Solar Power, Energy, Events, Facilities, National Solar Thermal Test Facility, News, News...

Note: This page contains sample records for the topic "load three-junction concentrator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Sandia National Laboratories: Concentrating Solar Power  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Sandia and EMCORE: Solar Photovoltaics, Fiber Optics, MODE, and Energy Efficiency On March 29, 2013, in Concentrating Solar Power, Energy, Partnership, Photovoltaic, Renewable...

362

Sandia National Laboratories: Concentrating Solar Power  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Center in Vermont Achieves Milestone Installation On September 23, 2014, in Concentrating Solar Power, Energy, Facilities, National Solar Thermal Test Facility, News, News &...

363

Concentrating Solar Power Resources and Technologies  

Broader source: Energy.gov [DOE]

This page provides a brief overview of concentrating solar power (CSP) technologies supplemented by specific information to apply CSP within the Federal sector.

364

A combined microfluidic/dielectrophoretic microorganism concentrator  

E-Print Network [OSTI]

This thesis presents the development of a high-throughput microfluidic microorganism concentrator for pathogen detection applications. Interdigitated electrodes lining the bottom of the channel use positive dielectrophoretic ...

Gadish, Nitzan

2005-01-01T23:59:59.000Z

365

Alignment method for parabolic trough solar concentrators  

DOE Patents [OSTI]

A Theoretical Overlay Photographic (TOP) alignment method uses the overlay of a theoretical projected image of a perfectly aligned concentrator on a photographic image of the concentrator to align the mirror facets of a parabolic trough solar concentrator. The alignment method is practical and straightforward, and inherently aligns the mirror facets to the receiver. When integrated with clinometer measurements for which gravity and mechanical drag effects have been accounted for and which are made in a manner and location consistent with the alignment method, all of the mirrors on a common drive can be aligned and optimized for any concentrator orientation.

Diver, Richard B. (Albuquerque, NM)

2010-02-23T23:59:59.000Z

366

Change in Contaminant Concentration in Fraser  

E-Print Network [OSTI]

during this period: dioxins, furans, polycyclic aromatic hydrocarbons (PAHs), chlorophenolics, resin to the peak in suspended sediment concentration during the freshet sampling period, iv) dioxins

367

Sandia National Laboratories: Concentrating Solar Power: Efficiently...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Funding Award On June 4, 2014, in Advanced Materials Laboratory, Concentrating Solar Power, Energy, Energy Storage, Facilities, National Solar Thermal Test Facility,...

368

Concentrating Solar Power (Revised) (Fact Sheet)  

SciTech Connect (OSTI)

The fact sheet summarizes the goals and activities of the DOE Solar Energy Technologies Program efforts within its concentrating solar power subprogram.

Not Available

2010-11-01T23:59:59.000Z

369

Microtracking and Self-Adaptive Solar Concentration  

Broader source: Energy.gov [DOE]

This presentation was delivered at the SunShot Concentrating Solar Power (CSP) Program Review 2013, held April 23–25, 2013 near Phoenix, Arizona.

370

Low-Cost, Lightweight Solar Concentrators  

Broader source: Energy.gov (indexed) [DOE]

Concentrators California Institute of TechnologyJet Propulsion Laboratory Award Number:0595-1612 | April 18, 2013 | Ganapathi * Mirror module development has been approached with...

371

Concentrating Solar Power: Energy from Mirrors  

SciTech Connect (OSTI)

This fact sheet explains how concentrating solar power technology works and the three types of systems in development today: trough, dish, and central receiver.

Poole, L.

2001-02-27T23:59:59.000Z

372

Innovative process for concentration of fine particle coal slurries. Technical report, March 1- May 31, 1996  

SciTech Connect (OSTI)

Williams Technologies, Inc. And Clarke Rajchel Engineering are developing a technology (patent pending) to produce high quality coal water slurries from preparation plant fine coal streams. The WTI/CRE technology uses the novel implementation of high-shear cross-flow separation which replaces and enhances conventional thickening processes by surpassing normally achievable solids loadings. Dilute ultra-fine (minus 100 mesh) solids slurries can be, concentrated to greater than 60 weight percent and re-mixed, as required, with de-watered coarser fractions to produce pumpable, heavily loaded coal slurries. The permeate (filtrate) resulting from this process has been demonstrated to be crystal clear and totally free of suspended solids. The primary objective of this project was to demonstrate the WTI/CRE coal slurry production process technology at the pilot scale. The technology can enable Illinois coal producers and users to realize significant cost and environmental benefits both by eliminating fine coal waste disposal problems and producing an IGCC fuel to produce power which meets all foreseeable clean air standards. Testing was also directed at concentrating mine tailings material to produce a tailings paste which can be mine-back-filled, eliminating the need for tailings ponds. During the grant period, a laboratory-scale test apparatus (up to 3 GPM feed rate) was assembled and operated to demonstrate process performance over a range of feed temperatures and pressures. A dilute coal/water slurry from Consol, Inc.`s Rend Lake Preparation Plant was concentrated using the process to a maximum recorded solids loading of 61.9% solids by weight. Analytical results from the concentrate were evaluated by Destec Energy for suitability as an IGCC fuel.

Rajchel, M.; Ehrlinger, H.P.; Fonseca, A.; Mauer, R.

1996-12-31T23:59:59.000Z

373

Estimating Demand Response Load Impacts: Evaluation of BaselineLoad Models for Non-Residential Buildings in California  

SciTech Connect (OSTI)

Both Federal and California state policymakers areincreasingly interested in developing more standardized and consistentapproaches to estimate and verify the load impacts of demand responseprograms and dynamic pricing tariffs. This study describes a statisticalanalysis of the performance of different models used to calculate thebaseline electric load for commercial buildings participating in ademand-response (DR) program, with emphasis onthe importance of weathereffects. During a DR event, a variety of adjustments may be made tobuilding operation, with the goal of reducing the building peak electricload. In order to determine the actual peak load reduction, an estimateof what the load would have been on the day of the event without any DRactions is needed. This baseline load profile (BLP) is key to accuratelyassessing the load impacts from event-based DR programs and may alsoimpact payment settlements for certain types of DR programs. We testedseven baseline models on a sample of 33 buildings located in California.These models can be loosely categorized into two groups: (1) averagingmethods, which use some linear combination of hourly load values fromprevious days to predict the load on the event, and (2) explicit weathermodels, which use a formula based on local hourly temperature to predictthe load. The models were tested both with and without morningadjustments, which use data from the day of the event to adjust theestimated BLP up or down.Key findings from this study are: - The accuracyof the BLP model currently used by California utilities to estimate loadreductions in several DR programs (i.e., hourly usage in highest 3 out of10 previous days) could be improved substantially if a morning adjustmentfactor were applied for weather-sensitive commercial and institutionalbuildings. - Applying a morning adjustment factor significantly reducesthe bias and improves the accuracy of all BLP models examined in oursample of buildings. - For buildings with low load variability, all BLPmodels perform reasonably well in accuracy. - For customer accounts withhighly variable loads, we found that no BLP model produced satisfactoryresults, although averaging methods perform best in accuracy (but notbias). These types of customers are difficult to characterize withstandard BLP models that rely on historic loads and weather data.Implications of these results for DR program administrators andpolicymakersare: - Most DR programs apply similar DR BLP methods tocommercial and industrial sector customers. The results of our study whencombined with other recent studies (Quantum 2004 and 2006, Buege et al.,2006) suggests that DR program administrators should have flexibility andmultiple options for suggesting the most appropriate BLP method forspecific types of customers.

Coughlin, Katie; Piette, Mary Ann; Goldman, Charles; Kiliccote,Sila

2008-01-01T23:59:59.000Z

374

Shipboard applications of non-intrusive load monitoring  

E-Print Network [OSTI]

The Non-Intrusive Load Monitor (NILM) provides a method of measuring component performance and source power quality through a single point of entry in the power distribution system. A study was performed utilizing the NILM ...

Ramsey, Jack S

2004-01-01T23:59:59.000Z

375

analysis load: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

of a water-loaded structure excited by an impulse force is of interest for the acoustic stealth of submarines Paris-Sud XI, Universit de 43 Mechanics of Fastening System Rail...

376

Undrained behavior of plate anchors subjected to general loading  

E-Print Network [OSTI]

This study presents a method for predicting the undrained behavior of plate anchors, including out-of-plane loading of simple plates and performance of suction embedded plate anchors (SEPLA). Three dimensional finite element models are used...

Yang, Ming

2010-01-14T23:59:59.000Z

377

Characterizing tensile loading responses of 3D printed samples  

E-Print Network [OSTI]

An experimental study was performed to characterize the loading response of samples manufactured through 3D printing. Tensile testing was performed on a number of 3D printed samples created through Fused Filament Fabrication ...

Haid, Christopher M

2014-01-01T23:59:59.000Z

378

Review of Residential Low-Load HVAC Systems  

SciTech Connect (OSTI)

In support of the U.S. Department of Energy’s (DOE’s) Building America Program, Pacific Northwest National Laboratory (PNNL) conducted an investigation to inventory commercially available HVAC technologies that are being installed in low-load homes. The first step in this investigation was to conduct a review of published literature to identify low-load HVAC technologies available in the United States and abroad, and document the findings of existing case studies that have evaluated the performance of the identified technologies. This report presents the findings of the literature review, identifies gaps in the literature or technical understanding that must be addressed before low-load HVAC technologies can be fully evaluated, and introduces PNNL’s planned research and analysis for this project to address identified gaps and potential future work on residential low-load HVAC systems.

Brown, Scott A.; Thornton, Brian; Widder, Sarah H.

2013-09-01T23:59:59.000Z

379

Minimized Space Conditioning Distribution Strategy for Low-load Homes  

Broader source: Energy.gov [DOE]

This presentation was given at the Summer 2012 DOE Building America meeting on July 26, 2012, and addressed the question ŤWhat are the best HVAC solutions for low-load, high performance homes?"

380

Analytical Methods for Implementing Industrial Load Management Programs  

E-Print Network [OSTI]

Many utilities have completed long-term planning studies and have shown that a load management program is cost effective. They are now actively implementing large-scale, system-wide programs such as demand subscription, interruptable rates, and time...

Hassig, N.; Chan, M.; Carlson, R.

1982-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "load three-junction concentrator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Electrical Energy Conservation and Load Management - An Industrial User's Viewpoint  

E-Print Network [OSTI]

Conservation of electrical energy and load management can reduce industry's electric bills, conserves natural resources and reduces the need for new generating plants. In recent years, industry has implemented extensive conservation programs. Some...

Jackson, C. E.

1984-01-01T23:59:59.000Z

382

Nutrient sources and loadings for the proposed Millican Lake  

E-Print Network [OSTI]

to Lee(14), sources of phosphorus and nitrogen in urban runoff include fertilizers used on lawns, dust fall, leaves, wastes from pets, automobile ngine cmiosicns, and othe- combustion sources. Weibel, et al. , (38) found total phosphorus loadings of 0...

Vigil, Samuel Alexander

1974-01-01T23:59:59.000Z

383

Hanford Apatite Treatability Test Report Errata: Apatite Mass Loading Calculation  

SciTech Connect (OSTI)

The objective of this errata report is to document an error in the apatite loading (i.e., treatment capacity) estimate reported in previous apatite treatability test reports and provide additional calculation details for estimating apatite loading and barrier longevity. The apatite treatability test final report (PNNL-19572; Vermeul et al. 2010) documents the results of the first field-scale evaluation of the injectable apatite PRB technology. The apatite loading value in units of milligram-apatite per gram-sediment is incorrect in this and some other previous reports. The apatite loading in units of milligram phosphate per gram-sediment, however, is correct, and this is the unit used for comparison to field core sample measurements.

Szecsody, James E.; Vermeul, Vincent R.; Williams, Mark D.; Truex, Michael J.

2014-05-19T23:59:59.000Z

384

Adaptive load control of microgrids with non-dispatchable generation  

E-Print Network [OSTI]

Intelligent appliances have a great potential to provide energy storage and load shedding for power grids. Microgrids are simulated with high levels of wind energy penetration. Frequency-adaptive intelligent appliances are ...

Brokish, Kevin Martin

2009-01-01T23:59:59.000Z

385

A framework for non-intrusive load monitoring and diagnostics  

E-Print Network [OSTI]

The widespread use of electrical and electromechanical systems places increasing demands on monitoring and diagnostic techniques. The non-intrusive load monitor (NILM) provides a low-cost, low-maintenance way to perform ...

Paris, James, Ph. D. Massachusetts Institute of Technology

2006-01-01T23:59:59.000Z

386

Improving shipboard applications of non-intrusive load monitoring  

E-Print Network [OSTI]

The Non-Intrusive Load Monitor (NILM) measures equipment performance by measuring and analyzing the source power to the equipment at a single point in the electrical system. Previous studies have proven the usefulness of ...

Jones, Richard A. (Richard Alan), Nav. E. Massachusetts Institute of Technology

2008-01-01T23:59:59.000Z

387

Grid Integration of Aggregated Demand Response, Part I: Load Availability  

E-Print Network [OSTI]

LBNL-6417E Grid Integration of Aggregated Demand Response, Part I: Load Availability Profiles Resources 4 #12;#12;#12;CHAPTER 3: Results: DR Profiles 3.1 Projected Demand Response Availability in 2020

388

An Innovative Approach Towards National Peak Load Management  

E-Print Network [OSTI]

An innovative approach was developed and implemented in eight governmental buildings to reduce their load during the peak demand hours in summer of 2007. The innovative approach implemented in these buildings included pre-closing treatment (PCT...

Al-Mulla, A.; Maheshwari, G. P.; Al-Nakib, D.; ElSherbini, A.; Alghimlas, F.; Al-Taqi, H.; Al-Hadban, Y.

389

Preconditioning Outside Air: Cooling Loads from Building Ventilation  

E-Print Network [OSTI]

of the standard. To mitigate or nullify these additional weather loads, outdoor air preconditioning technologies are being promoted in combination with conventional HVAC operations downstream as a means to deliver the required fresh air and control humidity...

Kosar, D.

1998-01-01T23:59:59.000Z

390

Energy Storage for Use in Load Frequency Control  

E-Print Network [OSTI]

Certain energy storage technologies are well-suited to the high-frequency, high-cycling operation which is required in provision of load frequency control (LFC). To limit the total stored energy capacity required while ...

Leitermann, Olivia

391

Load flow analysis: Base cases, data, diagrams, and results  

SciTech Connect (OSTI)

This report describes how an electric utility system is modeled by using load flow techniques to establish a validated power flow case suitable for simulating and evaluating alternative system scenarios. Details of the load flow model are supported by additional technical and descriptive information intended to correlate modeled electrical system parameters with the corresponding physical equipment that makes up the system. Pictures and technical specifications of system equipment from the utility, public, or vendor are provided to support this association for many system components. The report summarizes the load flow model construction, simulation, and validation and describes the general capabilities of an information query system designed to access load flow parameters and other electrical system information.

Portante, E.C.; Kavicky, J.A.; VanKuiken, J.C.; Peerenboom, J.P.

1997-10-01T23:59:59.000Z

392

Quantification of NPS Pollution Loads Within Pennsylvania Watersheds  

E-Print Network [OSTI]

Quantification of NPS Pollution Loads Within Pennsylvania Watersheds Final Report for Task 9 - BLWC for Atmospheric Deposition .................................... 2.4.5 Data Analyses for Urban Storm Runoff-Agricultural Fertilization ...................................................... 3.4 Atmospheric Deposition

Guiltinan, Mark

393

Nutrient load analysis of Lago de Yojoa, Honduras  

E-Print Network [OSTI]

Lake Yojoa, Honduras is an important natural resource to the people of Honduras. The lake's water quality has been a controversial subject. This thesis describes a nutrient load analysis performed to gain a better understanding ...

Trate, Tia M. (Tia Marie)

2006-01-01T23:59:59.000Z

394

Laser ablation loading of a surface-electrode ion trap  

E-Print Network [OSTI]

We demonstrate loading by laser ablation of $^{88}$Sr$^+$ ions into a mm-scale surface-electrode ion trap. The laser used for ablation is a pulsed, frequency-tripled Nd:YAG with pulse energies of 1-10 mJ and durations of 3-5 ns. An additional laser is not required to photoionize the ablated material. The efficiency and lifetime of several candidate materials for the laser ablation target are characterized by measuring the trapped ion fluorescence signal for a number of consecutive loads. Additionally, laser ablation is used to load traps with a trap depth (40 meV) below where electron impact ionization loading is typically successful ($\\gtrsim$ 500 meV).

David R. Leibrandt; Robert J. Clark; Jaroslaw Labaziewicz; Paul Antohi; Waseem Bakr; Kenneth R. Brown; Isaac L. Chuang

2007-06-22T23:59:59.000Z

395

Responses of an articulated loading platform in waves and currents  

E-Print Network [OSTI]

The responses of an articulated loading platform (ALP) in regular and irregular unidirectional waves (with or without currents) are investigated both in frequency and time domain. The first- and second-order wave diffraction radiation are solved...

Ran, Zhihuang

1993-01-01T23:59:59.000Z

396

Loading guide for dry-type power transformers  

E-Print Network [OSTI]

Applicable to naturally cooled dry-type power transformers complying with IEC 60726. Permits the calculation of, and indicates the permissible loading under certain defined conditions in terms of rated current.

International Electrotechnical Commission. Geneva

1987-01-01T23:59:59.000Z

397

MANAGEMENT INFORMATION SYSTEMS (MIS) CONCENTRATION FOR UNDERGRADUATES  

E-Print Network [OSTI]

MANAGEMENT INFORMATION SYSTEMS (MIS) CONCENTRATION FOR UNDERGRADUATES The management information systems concentration, like a major, focuses on the use of information technology for value creation creation. Link to Rensselaer 2012-2013 Catalog Required Courses MGMT 4240 Systems Analysis & Design MGMT

Salama, Khaled

398

Requirements for a Concentration in Energy Technologies  

E-Print Network [OSTI]

Technologies ­ 4 cr ENG EC 417 ­ Electric Energy Systems: Adapting to Renewable Resources ­ 4 cr Additional* - Methods of Environmental Policy ­ 4 cr ENG ME 533 ­ Energy Conversion ­ 4 cr ENG EC/ME/SE 543Requirements for a Concentration in Energy Technologies The concentration in Energy Technologies

399

EFFECTS OF VARIOUS CONCENTRATIONS OF DDT  

E-Print Network [OSTI]

EFFECTS OF VARIOUS CONCENTRATIONS OF DDT ON SEVERAL SPECIES OF FISH OF DIFFERENT SIZES Marine Biiii OF VARIOUS CONCENTRATIONS OF DDT ON SEVERAL SPECIES OF FISH OF DIFFERENT SIZES Marine Binlo^'i., i i Report - Fisheries No. U EFFECTS OF VARIOUS 0ONCENTRATI)^S OF DDT ON SEVEKAL SPECIES OF FISH OF DIFFERENT

400

A model for short term electric load forecasting  

E-Print Network [OSTI]

A MODEL FOR SHORT TERM ELECTRIC LOAD FORECASTING A Thesis by JOHN ROBERT TIGUE, III Submitted to the Graduate College of Texas ASM University in partial fulfillment of the requirement for the degree of MASTER OF SCIENCE May 1975 Major... Subject: Electrical Engineering A MODEL FOR SHORT TERM ELECTRIC LOAD FORECASTING A Thesis by JOHN ROBERT TIGUE& III Approved as to style and content by: (Chairman of Committee) (Head Depart t) (Member) ;(Me r (Member) (Member) May 1975 ABSTRACT...

Tigue, John Robert

1975-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "load three-junction concentrator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

An experimental investigation of eccentrically loaded riveted and bolted connections  

E-Print Network [OSTI]

L&HRARy, ?AGE DF TEg~ AN EXPERIMENTAL INVESTIGATION ECCENTRICXLLY LOADED RIVETED AND BOLTED CONNECTIONS by Samy L', G. Elias A Thesis Submitted to the Graduate School of The Agricultural and Mechanical College of Texas In Partial... Fulfillment of the Requirements for the Degree of Master of Science January 1958 Department of Aeronautical Engineering Major Subject: Aeronautical Engineering AN EXPERIMENTAL INVESTIGATION OF ECCENTRICALLY LOADED RIVETED AND BOLTED CONNECTIONS A...

Elias, Samy E. G

1958-01-01T23:59:59.000Z

402

A development of MOS linear active load schemes  

E-Print Network [OSTI]

A DEVELOPMENT OF MOS LINEAR ACTIVE LOAD SCHEMES A Thesis by ROBERT ALAN MALLETT Submitted to the Graduate College of Texas AgrM University in partial fulfillment of the requirement for the degree of MASTER OF SCIENCE December 1985 Major...-Angulo ( ember) Thomas R. Fischer (Member) Charl lover (Member) J. W. Howze (Head of Department) December 1985 ABSTRACT The Development of MOS Linear Active Load Schemes. (December 1985) Robert Alan Mallett, B, S, , South Dakota State University...

Mallett, Robert Alan

1985-01-01T23:59:59.000Z

403

Improved load models for multi-area reliability calculations  

E-Print Network [OSTI]

IMPROVED LOAD MODELS FOR MULTI-AREA RELIABILITY CALCULATIONS A Thesis by SANJESH PATHAK Submitted to the Office of Graduate Studies of Texas ARM University in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE May... 1992 Major Subject: Electrical Engineering IMPROVED LOAD MODELS FOR MULTI-AREA RELIABILITY CALCULATIONS A Thesis by SAN JESH PATHAK Approved as to style and content by: Chanan Singh (Chair of Committee) Prasad Enjeti (Member) Ces . Mal, e...

Pathak, Sanjesh

1992-01-01T23:59:59.000Z

404

High load operation in a homogeneous charge compression ignition engine  

DOE Patents [OSTI]

A homogeneous charge compression ignition engine is set up by first identifying combinations of compression ratio and exhaust gas percentages for each speed and load across the engines operating range. These identified ratios and exhaust gas percentages can then be converted into geometric compression ratio controller settings and exhaust gas recirculation rate controller settings that are mapped against speed and load, and made available to the electronic

Duffy, Kevin P. (Metamora, IL); Kieser, Andrew J. (Morton, IL); Liechty, Michael P. (Chillicothe, IL); Hardy, William L. (Peoria, IL); Rodman, Anthony (Chillicothe, IL); Hergart, Carl-Anders (Peoria, IL)

2008-12-23T23:59:59.000Z

405

A study conducted on laterally loaded cylindrical footings  

E-Print Network [OSTI]

A STUDY CONDUCTED ON LATERALLY LOADED CYLINDRICAL FOOTINGS A Thesis by Kenneth Joseph Koch Submitted to the Graduate College of the Texas A&M University in partial fulfillment of the requirements for the degree oi MASTER OF SCIENCE May 1968... Major Subject Civil Engineering A STUDY CONDUCTED ON LATERALLY LOADED CYLINDRICAL FOOTINGS A Thesis by Kenneth Joseph Koch Approved as to style and content by (Chairman of Committee) (Head of Department) (Member) (M ber) May 1968...

Koch, Kenneth Joseph

1968-01-01T23:59:59.000Z

406

Incremental cooling load determination for passive direct gain heating systems  

SciTech Connect (OSTI)

This paper examines the applicability of the National Association of Home Builders (NAHB) full load compressor hour method for predicting the cooling load increase in a residence, attributable to direct gain passive heating systems. The NAHB method predictions are compared with the results of 200 hour-by-hour simulations using BLAST and the two methods show reasonable agreement. The degree of agreement and the limitations of the NAHB method are discussed.

Sullivan, P.W.; Mahone, D.; Fuller, W.; Gruber, J.; Kammerud, R.; Place, W.; Andersson, B.

1981-05-01T23:59:59.000Z

407

Development of load and resistance factor design for FRP strengthening of reinforced concrete structures  

E-Print Network [OSTI]

distribution and the loads follow normal distributions.of time-span specific load models follows, a more detailedfollows the technique detailed in the Transportation Research Circular, Calibration to Determine Load and

Atadero, Rebecca Anne

2006-01-01T23:59:59.000Z

408

Influence of raised floor on zone design cooling load in commercial buildings.  

E-Print Network [OSTI]

office”. The equipment loads follow the schedules of theload is 10.8 W/m 2 and it follows the load shown in Table 3.interior zone follows the internal heat load, i.e. people

Schiavon, Stefano; Lee, Kwang Ho; Bauman, Fred; Webster, Tom

2010-01-01T23:59:59.000Z

409

Experimental damage-gas flow correlations for cyclically loaded reinforced concrete walls  

E-Print Network [OSTI]

performed on specimen U6 following load step P/P o = 1.50 isvalues measured at the load step following first crack fortests at the load step following first crack, therefore,

Soppe, Travis E.

2009-01-01T23:59:59.000Z

410

Determination of the Price-Load Curve by Using Smoothing Splines Under Tension  

E-Print Network [OSTI]

Determination of the Price-Load Curve by Using Smoothing Splines Under Tension Master Thesis 4.2. Price-Load Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 4 load and price . . . . . . . . . . . . . . . . . . . . . . 6 1.5. Merit order curve with operating

411

Analytical Modeling of Wood Frame Shear Walls Subjected to Vertical Load  

E-Print Network [OSTI]

A nonlinear automated parameter fitted analytical model that numerically predicts the load-displacement response of wood frame shear walls subjected to static monotonic loading with and without vertical load is presented. This analytical model...

Nguyendinh, Hai

2011-08-08T23:59:59.000Z

412

Spatiotemporal nutrient loading to Cultus Lake: Context for eutrophication and implications for  

E-Print Network [OSTI]

Spatiotemporal nutrient loading to Cultus Lake: Context for eutrophication and implications of Thesis: Spatiotemporal nutrient loading to Cultus Lake: Context for eutrophication and implications Cultus Lake, British Columbia experiences significant anthropogenic nutrient loadings and eutrophication

413

Modeling of FRP-jacketed RC columns subject to combined axial and lateral loads  

E-Print Network [OSTI]

LOCATIONS #6 u-bars @ 4" 3" PVC for axial load and verticalsteel Steel jacket encasing load stub 2" PVC for clevisattatch 3" PVC for axial load A B Vertical tiedown Column

Lee, Chung-Sheng

2006-01-01T23:59:59.000Z

414

Development of a simplified cooling load design tool for underfloor air distribution (UFAD) systems.  

E-Print Network [OSTI]

occupants) W = zone cooling load (supply and return plenumm]. W L is the zone cooling load (supply and return plenumthe total UFAD cooling load between the supply plenum, the

Schiavon, Stefano; Lee, Kwang Ho; Bauman, Fred; Webster, Tom

2010-01-01T23:59:59.000Z

415

Simplified calculation method for design cooling loads in underfloor air distribution (UFAD) systems  

E-Print Network [OSTI]

of the UFAD cooling load between the supply plenum, zone (split the UFAD cooling load into the supply plenum, the zonesplit the UFAD cooling load into the supply plenum, zone and

Schiavon, Stefano; Lee, Kwang Ho; Bauman, Fred; Webster, Tom

2010-01-01T23:59:59.000Z

416

Pilot plant used to develop load and pressure controller  

SciTech Connect (OSTI)

Viewed from the perspective of the power-generation mixture in Japan, nuclear power plants will continue to be operated to meet the base load. Meanwhile, integrated coal gasification combined cycle (IGCC) power plants will be required to serve as thermal power plants to cover the middle load, as is the case with conventional thermal power plants. In terms of operational performance, therefore, IGCC power plants will need to have a capability of following a wide range of load demand at high speed. For this purpose, a load and pressure controller was developed and tested during the operational research on a 200 tons/day entrained flow IGCC pilot plant at the Nakoso Power Station by the Engineering Research Association for IGCC Power Systems (IGC Association). This article reports on the development of the load and pressure controller and the results of the control test carried out to check the load follow capability of the pilot plant, while touching upon the simulation study also being conducted.

Nagata, Kazue; Yamada, Toshihiro; Hiza, Tomoyuki

1997-02-01T23:59:59.000Z

417

Transportation Electrification Load Development For A Renewable Future Analysis: Preprint  

SciTech Connect (OSTI)

The transition to electricity as a transportation fuel will create a new load for electricity generation. A set of regional hourly load profiles for electrified vehicles was developed for the 2010 to 2050 timeframe. The transportation electrical energy was determined using regional population forecast data, historical vehicle per capita data, and market penetration growth functions to determine the number of plug-in electric vehicles (PEVs) in each analysis region. Market saturation scenarios of 30% and 50% of sales of PEVs consuming on average approx. 6 kWh per day were considered. PEV aggregate load profiles from previous work were combined with vehicle population data to generate hourly loads on a regional basis. A transition from consumer-controlled charging toward utility-controlled charging was assumed such that by 2050 approximately 45% of the transportation energy demands could be delivered across four daily time slices under optimal control from the utility?s perspective. This electrified transportation analysis resulted in an estimate for both the flexible load and fixed load shapes on a regional basis that may evolve under two PEV market penetration scenarios.

Markel, T.; Mai, T.; Kintner-Meyer, M.

2010-12-01T23:59:59.000Z

418

Selecting a Control Strategy for Plug and Process Loads  

SciTech Connect (OSTI)

Plug and Process Loads (PPLs) are building loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the building occupants. PPLs in commercial buildings account for almost 5% of U.S. primary energy consumption. On an individual building level, they account for approximately 25% of the total electrical load in a minimally code-compliant commercial building, and can exceed 50% in an ultra-high efficiency building such as the National Renewable Energy Laboratory's (NREL) Research Support Facility (RSF) (Lobato et al. 2010). Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. A complex array of technologies that measure and manage PPLs has emerged in the marketplace. Some fall short of manufacturer performance claims, however. NREL has been actively engaged in developing an evaluation and selection process for PPLs control, and is using this process to evaluate a range of technologies for active PPLs management that will cap RSF plug loads. Using a control strategy to match plug load use to users' required job functions is a huge untapped potential for energy savings.

Lobato, C.; Sheppy, M.; Brackney, L.; Pless, S.; Torcellini, P.

2012-09-01T23:59:59.000Z

419

Application of Distribution Transformer Thermal Life Models to Electrified Vehicle Charging Loads Using Monte-Carlo Method: Preprint  

SciTech Connect (OSTI)

Concentrated purchasing patterns of plug-in vehicles may result in localized distribution transformer overload scenarios. Prolonged periods of transformer overloading causes service life decrements, and in worst-case scenarios, results in tripped thermal relays and residential service outages. This analysis will review distribution transformer load models developed in the IEC 60076 standard, and apply the model to a neighborhood with plug-in hybrids. Residential distribution transformers are sized such that night-time cooling provides thermal recovery from heavy load conditions during the daytime utility peak. It is expected that PHEVs will primarily be charged at night in a residential setting. If not managed properly, some distribution transformers could become overloaded, leading to a reduction in transformer life expectancy, thus increasing costs to utilities and consumers. A Monte-Carlo scheme simulated each day of the year, evaluating 100 load scenarios as it swept through the following variables: number of vehicle per transformer, transformer size, and charging rate. A general method for determining expected transformer aging rate will be developed, based on the energy needs of plug-in vehicles loading a residential transformer.

Kuss, M.; Markel, T.; Kramer, W.

2011-01-01T23:59:59.000Z

420

Interaction of watershed scale and pollutant transport pathways on pollutant concentrations in rivers  

SciTech Connect (OSTI)

Extensive studies of pollutant concentrations during both storm runoff events and non-storm periods have been underway in Ohio tributaries to lake Erie since 1974. More than 60,000 samples have been collected using automatic samplers located at US Geological Survey stream gauging stations. Drainage areas at the collection stations range from 11 km{sup 2} to 16,400 km{sup 2}. Samples have been analyzed for suspended sediments, various particulate pollutants attached to suspended sediments, current generation herbicides, nitrates, and chlorides. In general, for pollutants derived from nonpoint sources, peak concentrations decrease as watershed size increases. However, the duration of exposures to intermediate concentrations increases with increasing watershed size. these effects are most evident for suspended solids and associated particulate contaminants. For pollutants derived primarily from surface runoff but not attached to suspended sediments, the effects of watershed size on peak concentrations are evident, but not as pronounced as for suspended sediments. For compounds such as nitrates, which enter streams largely through interflow or tile drainage, scale effects are least evident. These scale effects are most likely attributable to dilution accompanying storm water routing through drainage networks. Longitudinal dispersion may also affect concentration patterns. These scale effects systematically affect exposure patterns in different positions in drainage networks and must be considered in designing sampling programs to assess impacts of nonpoint pollution on contaminant concentration patterns and loadings.

Baker, D.; Richards, R.P.; Kramer, J.W. [Heidelberg Coll., Tiffin, OH (United States). Water Quality Lab.

1995-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "load three-junction concentrator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Development and application of the spatially explicit load enrichment calculation tool (select) to determine potential E. coli loads in watersheds  

E-Print Network [OSTI]

According to the USEPA National Section 303(d) List Fact Sheet, bacterial pathogens are the leading cause of water quality impairments in Texas. The automated Spatially Explicit Load Enrichment Calculation Tool (SELECT) uses spatially variable...

Riebschleager, Kendra Jean

2009-05-15T23:59:59.000Z

422

Measured electric hot water standby and demand loads from Pacific Northwest homes. End-Use Load and Consumer Assessment Program  

SciTech Connect (OSTI)

The Bonneville Power Administration began the End-Use Load and Consumer Assessment Program (ELCAP) in 1983 to obtain metered hourly end-use consumption data for a large sample of new and existing residential and commercial buildings in the Pacific Northwest. Loads and load shapes from the first 3 years of data fro each of several ELCAP residential studies representing various segments of the housing population have been summarized by Pratt et al. The analysis reported here uses the ELCAP data to investigate in much greater detail the relationship of key occupant and tank characteristics to the consumption of electricity for water heating. The hourly data collected provides opportunities to understand electricity consumption for heating water and to examine assumptions about water heating that are critical to load forecasting and conservation resource assessments. Specific objectives of this analysis are to: (A) determine the current baseline for standby heat losses by determining the standby heat loss of each hot water tank in the sample, (B) examine key assumptions affecting standby heat losses such as hot water temperatures and tank sizes and locations, (C) estimate, where possible, impacts on standby heat losses by conservation measures such as insulating tank wraps, pipe wraps, anticonvection valves or traps, and insulating bottom boards, (D) estimate the EF-factors used by the federal efficiency standards and the nominal R-values of the tanks in the sample, (E) develop estimates of demand for hot water for each home in the sample by subtracting the standby load from the total hot water load, (F) examine the relationship between the ages and number of occupants and the hot water demand, (G) place the standby and demand components of water heating electricity consumption in perspective with the total hot water load and load shape.

Pratt, R.G.; Ross, B.A.

1991-11-01T23:59:59.000Z

423

Mercury concentrations in Maine sport fishes  

SciTech Connect (OSTI)

To assess mercury contamination of fish in Maine, fish were collected from 120 randomly selected lakes. The collection goal for each lake was five fish of the single most common sport fish species within the size range commonly harvested by anglers. Skinless, boneless fillets of fish from each lake were composited, homogenized, and analyzed for total mercury. The two most abundant species, brook trout Salvelinus fontinalis and smallmouth bass Micropterus dolomieu, were also analyzed individually. The composite fish analyses indicate high concentrations of mercury, particularly in large and long-lived nonsalmonid species. Chain pickerel Esox niger, smallmouth bass, largemouth bass Micropterus salmoides, and white perch Morone americana had the highest average mercury concentrations, and brook trout and yellow perch Perca flavescens had the lowest. The mean species composite mercury concentration was positively correlated with a factor incorporating the average size and age of the fish. Lakes containing fish with high mercury concentrations were not clustered near known industrial or population centers but were commonest in the area within 150 km of the seacoast, reflecting the geographical distribution of species that contained higher mercury concentrations. Stocked and wild brook trout were not different in length or weight, but wild fish were older and had higher mercury concentrations. Fish populations maintained by frequent introductions of hatchery-produced fish and subject to high angler exploitation rates may consist of younger fish with lower exposure to environmental mercury and thus contain lower concentrations than wild populations.

Stafford, C.P. [Univ. of Maine, Orono, ME (United States)] [Univ. of Maine, Orono, ME (United States); Haines, T.A. [Geological Survey, Orono, ME (United States)] [Geological Survey, Orono, ME (United States)

1997-01-01T23:59:59.000Z

424

E-Print Network 3.0 - assembly loading pattern Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

loading pattern Search Powered by Explorit Topic List Advanced Search Sample search results for: assembly loading pattern Page: << < 1 2 3 4 5 > >> 1 Preferred Presentation Mode:...

425

Design of an Experimental Facility for the Validation of Cooling Load Calculation Procedures.  

E-Print Network [OSTI]

??Two test cells were constructed to validate the ASHRAE cooling load calculation procedures developed under RP-875 and codified in the ASHRAE Loads Toolkit (RP987). The… (more)

Eldridge, David Stewart

2007-01-01T23:59:59.000Z

426

Analysis of Wind Power and Load Data at Multiple Time Scales  

E-Print Network [OSTI]

Minnesota statewide wind integration study. November 2006.It would be very useful to wind integration studies if thisof net load vs. load Wind integration studies are generally

Coughlin, Katie

2011-01-01T23:59:59.000Z

427

Simplified calculation method for design cooling loads in underfloor air distribution (UFAD) systems  

E-Print Network [OSTI]

Underfloor Air Distribution (UFAD) Design Guide, Americanfor design cooling loads in Underfloor Air Distribution (for design cooling loads in underfloor air distribution (

Schiavon, Stefano; Lee, Kwang Ho; Bauman, Fred; Webster, Tom

2010-01-01T23:59:59.000Z

428

Effect of sulfur loading on the desulfation chemistry of a commercial...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

sulfur loading on the desulfation chemistry of a commercial lean NOx trap catalyst. Effect of sulfur loading on the desulfation chemistry of a commercial lean NOx trap catalyst....

429

Comparison of Zone Cooling Load for Radiant and All-Air Conditioning Systems  

E-Print Network [OSTI]

heat gain is well recognized by cooling load calculationheat gain and building thermal mass, which is particularly important in cooling load calculation,

Feng, Jingjuan; Schiavon, Stefano; Bauman, Fred

2012-01-01T23:59:59.000Z

430

Cooling load calculations for radiant systems: are they the same traditional methods?  

E-Print Network [OSTI]

heat transfer is handled in traditional cooling load calculationheat gain is well recognized by cooling load calculationload calculations for radiant systems should use the ASHRAE heat

Bauman, Fred; Feng, Jingjuan Dove; Schiavon, Stefano

2013-01-01T23:59:59.000Z

431

Effect of K loadings on nitrate formation/decomposition and on...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

K loadings on nitrate formationdecomposition and on NOx storage performance of K-based NOx storage-reduction Effect of K loadings on nitrate formationdecomposition and on NOx...

432

E-Print Network 3.0 - alternating load strength Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

load... on the foundation will be small compared to the moment load derived from the wind and waves. ... Source: Byrne, Byron - Department of Engineering Science, University...

433

Uniform flux dish concentrators for photovoltaic application  

SciTech Connect (OSTI)

Researchers at the National Renewable Energy Laboratory (NREL) have designed a unique and innovative molded dish concentrator capable of producing a uniform flux profile on a flat target plane. Concentration levels of 100--200 suns, which are uniform over an area of several square inches, can be directly achieved for collection apertures of a reasonable size ({approximately}1.5-m diameter). Such performance would be immediately applicable to photovoltaic (PV) use. Economic concerns have shown that the proposed approach would be less expensive thatn Fresnel lens concepts or other dish concentrator designs that require complicated and costly receivers to mix the flux to obtain a uniform distribution. 12 refs.

Jorgensen, G; Wendelin, T

1992-05-01T23:59:59.000Z

434

Si concentrator solar cell development. [Final report  

SciTech Connect (OSTI)

This is the final report of a program to develop a commercial, high-efficiency, low-cost concentrator solar cell compatible with Spectrolab`s existing manufacturing infrastructure for space solar cells. The period covered is between 1991 and 1993. The program was funded through Sandia National Laboratories through the DOE concentrator initiative and, was also cost shared by Spectrolab. As a result of this program, Spectrolab implemented solar cells achieving an efficiency of over 19% at 200 to 300X concentration. The cells are compatible with DOE guidelines for a cell price necessary to achieve a cost of electricity of 12 cents a kilowatthour.

Krut, D.D. [Spectrolab, Inc., Sylmar, CA (United States)

1994-10-01T23:59:59.000Z

435

Transportation Electrification Load Development For a Renewable Future Analysis  

SciTech Connect (OSTI)

Electrification of the transportation sector offers the opportunity to significantly reduce petroleum consumption. The transportation sector accounts for 70% of US petroleum consumption. The transition to electricity as a transportation fuel will create a new load for electricity generation. In support of a recent US Department of Energy funded activity that analyzed a future generation scenario with high renewable energy technology contributions, a set of regional hourly load profiles for electrified vehicles were developed for the 2010 to 2050 timeframe. These load profiles with their underlying assumptions will be presented in this paper. The transportation electrical energy was determined using regional population forecast data, historical vehicle per capita data, and market penetration growth functions to determine the number of plug-in electric vehicles (PEVs) in each analysis region. Two market saturation scenarios of 30% of sales and 50% of sales of PEVs consuming on average {approx}6 kWh per day were considered. Results were generated for 3109 counties and were consolidated to 134 Power Control Areas (PCA) for the use NREL's's regional generation planning analysis tool ReEDS. PEV aggregate load profiles from previous work were combined with vehicle population data to generate hourly loads on a regional basis. A transition from consumer-controlled charging toward utility-controlled charging was assumed such that by 2050 approximately 45% of the transportation energy demands could be delivered across 4 daily time slices under optimal control from the utility perspective. No other literature has addressed the potential flexibility in energy delivery to electric vehicles in connection with a regional power generation study. This electrified transportation analysis resulted in an estimate for both the flexible load and fixed load shapes on a regional basis that may evolve under two PEV market penetration scenarios. EVS25 Copyright.

Markel, Tony; Mai, Trieu; Kintner-Meyer, Michael CW

2010-09-30T23:59:59.000Z

436

Line broadening studies on highly defective TiO/sub 2/ produced by high pressure shock loading  

SciTech Connect (OSTI)

Enhanced solid state reactivity of materials both during and after shock compression has been attributed to the introduction of large numbers of defects into the crystalline lattices and to reduction in the particle and crystalline size of powders. In particular, orders of magnitude increases in the catalytic activity has been observed in shock-modified TiO/sub 2/. Line broadening of x-ray diffraction profiles provides a means to determine the coherent crystallite size and the residual lattice strain resulting from defect concentrations. The present study on shock-loaded rutile is a detailed investigation of the influence of shock loading on residual lattice strain and coherent crystallite size. Annealing of shock-modified rutile powders is also studied.

Morosin, B.; Graeber, E.J.; Graham, R.A.

1983-01-01T23:59:59.000Z

437

Energy 101: Concentrating Solar Power | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Concentrating Solar Power Energy 101: Concentrating Solar Power Addthis Description From towers to dishes to linear mirrors to troughs, concentrating solar power (CSP) technologies...

438

Low-Cost Installation of Concentrating Photovoltaic  

E-Print Network [OSTI]

Low-Cost Installation of Concentrating Photovoltaic Renewable Energy Research Renewable Energy inhibit the potential growth of the California photovoltaic market: high installation costs, expenses improvements have been made in recent years on the assembly and deployment of flatplate photovoltaic

439

Sandia National Laboratories: Concentrating Solar Power  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Molten Salt Test Loop Melted Salt On October 10, 2012, in Concentrating Solar Power, Energy, News, Renewable Energy, Solar The Molten Salt Test Loop (MSTL) team at Sandia National...

440

Concentrating Solar Power Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

heat. This thermal energy can then be used to produce electricity via a steam turbine or heat engine that drives a generator. Concentrating solar power offers a utility-scale,...

Note: This page contains sample records for the topic "load three-junction concentrator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Physics and Astronomy Engineering Electronics Concentration  

E-Print Network [OSTI]

Physics and Astronomy Engineering Electronics Concentration Strongly recommended courses Credits PHY 3230 Thermal Physics 2 PHY 4330 Digital Electronics 3 PHY 4635 Advanced Microprocessors Grade PHY 4020 Computational Methods in Physics & Engineering 3 PHY 4620 Optics 4 PHY 4735

Thaxton, Christopher S.

442

Future trends in environmental mercury concentrations: implications  

E-Print Network [OSTI]

Future trends in environmental mercury concentrations: implications for prevention strategies interactions among natural and human climate system components; objectively assess uncertainty in economic, monitor and verify greenhouse gas emissions and climatic impacts. This reprint is one of a series intended

443

Advancing Concentrating Solar Power Research (Fact Sheet)  

SciTech Connect (OSTI)

Researchers at the National Renewable Energy Laboratory (NREL) provide scientific, engineering, and analytical expertise to help advance innovation in concentrating solar power (CSP). This fact sheet summarizes how NREL is advancing CSP research.

Not Available

2014-02-01T23:59:59.000Z

444

What does stabilizing greenhouse gas concentrations mean?  

E-Print Network [OSTI]

The MIT Emissions Prediction and Policy Analysis (EPPA) model is applied to an exploration of the national emissions obligations that would be required to stabilize atmospheric CO2 concentrations at levels now under active ...

Jacoby, Henry D.; Schmalensee, Richard.; Reiner, David M.

445

Concentrator E-F11 water test  

SciTech Connect (OSTI)

This document is the Process Test Report for performing operation testing with water of the modified E-F11 concentrator in PUREX on water. The test was performed to determine the effects of the following concentrator modifications; routing concentrator off-gasses via the PUREX air tunnel to the main stack, blanking of condenser cooling water, blanking of process condensate route to a crib, restricting flow to steam tube bundles, and routing of steam condensate to TK-F12. The test was successful. Concentrator boil-off rates of 6--7 gpm were achieved while the overheads exited the PUREX plant in vapor form. With minor recommended modifications, this process is recommended for use in processing PUREX deactivation flush solutions and other miscellaneous wastes accumulated during the completion of the deactivation project.

Ethington, P.R.

1994-02-25T23:59:59.000Z

446

DNA Concentration By UV Spectrophotometry Measure Absorption  

E-Print Network [OSTI]

DNA Concentration By UV Spectrophotometry Measure Absorption: 1. Dilute DNA to 0.5 to 50 µg 2. Measure absorption at 260 nm (A260). Start by zeroing instrument with TE buffer or dH2O alone

Aris, John P.

447

Landscape Design, Construction and Management Concentration  

E-Print Network [OSTI]

Landscape Design, Construction and Management Concentration Program of Study The Landscape for careers in the landscape and nursery industries, public gardens and arboreta. Opportunities include plant production, landscape design, construction and maintenance, marketing, management

Isaacs, Rufus

448

Concentrating solar power | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentrating Solar Power Basics (The following text is derived from NREL's concentrating solar

449

Self locking coupling mechanism for engaging and moving a load  

DOE Patents [OSTI]

Coupling mechanism (11) for engaging and lifting a load (12) has a housing (19) with a guide passage (18) for receiving a knob (13) which is secured to the load (12) through a neck (15) of smaller diameter. A hollow ball (23) in the housing (19) has an opening (27) which receives the knob (13) and the ball (23) is then turned to displace the opening (27) from the housing passage (18) and to cause the neck (15) to enter a slot (29) in the ball (23) thereby securing the load (12) to the coupling mechanism (11) as elements (49) of the housing (19) block travel of the neck (15) back into the opening (27) when the ball (23) is turned to the load holding orientation. As engagement of the load (12) and locking of the coupling mechanism are accomplished simultaneously by the same ball (23) motion, operation is simplified and reliability is greatly increased. The ball (23) is preferably turned by a motor (32) through worm gearing (36) and the coupling mechanism (11) may be controlled from a remote location. Among other uses, the coupling mechanism (11) is adaptable to the handling of spent nuclear reactor fuel elements (12).

Wood, Richard L. (Livermore, CA); Casamajor, Alan B. (Pleasanton, CA); Parsons, Richard E. (Orinda, CA)

1982-01-01T23:59:59.000Z

450

The evaluation of a turbulent loads characterization system  

SciTech Connect (OSTI)

In this paper we discuss an on-line turbulent load characterization system that has been designed to acquire loading spectra from turbines of the same design operating in several different environments and from different turbine designs operating in the same environment. This System simultaneously measures the rainflow-counted alternating and mean loading spectra and the hub-height turbulent mean shearing stress and atmospheric stability associated with the turbulent inflow. We discuss the theory behind the measurement configuration and the results of proof-of-concept testing recently performed at the National Wind Technology Center (NWTC) using a Bergey EXCEL-S 10-kW wind turbine. The on-line approach to characterizing the load spectra and the inflow turbulent scaling parameter produces results that are consistent with other measurements. The on-line approximation of the turbulent shear stress or friction velocity u* also is considered adequate. The system can be used to characterize turbulence loads during turbine deployment in a wide variety of environments. Using the WISPER protocol, we found that a wide-range, variable-speed turbine will accumulate a larger number of stress cycles in the low-cycle, high-amplitude (LCHA) region when compared with a constant speed rotor under similar inflow conditions.

Kelley, N.D.; McKenna, H.E. [National Renewable Energy Lab., Golden, CO (United States)

1996-01-01T23:59:59.000Z

451

Self locking coupling mechanism for engaging and moving a load  

DOE Patents [OSTI]

A coupling mechanism for engaging and lifting a load has a housing with a guide passage for receiving a knob which is secured to the load through a neck of smaller diameter. A hollow ball in the housing has an opening which receives the knob and the ball is then turned to displace the opening from the housing passage and to cause the neck to enter a slot in the ball thereby securing the load to the coupling mechanism as elements of the housing block travel of the neck back into the opening when the ball is turned to the load holding orientation. As engagement of the load and locking of the coupling mechanism are accomplished simultaneously by the same ball motion, operation is simplified and reliability is greatly increased. The ball is preferably turned by a motor through worm gearing and the coupling mechanism may be controlled from a remote location. Among other uses, the coupling mechanism is adaptable to the handling of spent nuclear reactor fuel elements.

Wood, R.L.; Casamajor, A.B.; Parsons, R.E.

1980-09-12T23:59:59.000Z

452

Reliability analysis and prediction of mixed mode load using Markov Chain Model  

SciTech Connect (OSTI)

The aim of this paper is to present the reliability analysis and prediction of mixed mode loading by using a simple two state Markov Chain Model for an automotive crankshaft. The reliability analysis and prediction for any automotive component or structure is important for analyzing and measuring the failure to increase the design life, eliminate or reduce the likelihood of failures and safety risk. The mechanical failures of the crankshaft are due of high bending and torsion stress concentration from high cycle and low rotating bending and torsional stress. The Markov Chain was used to model the two states based on the probability of failure due to bending and torsion stress. In most investigations it revealed that bending stress is much serve than torsional stress, therefore the probability criteria for the bending state would be higher compared to the torsion state. A statistical comparison between the developed Markov Chain Model and field data was done to observe the percentage of error. The reliability analysis and prediction was derived and illustrated from the Markov Chain Model were shown in the Weibull probability and cumulative distribution function, hazard rate and reliability curve and the bathtub curve. It can be concluded that Markov Chain Model has the ability to generate near similar data with minimal percentage of error and for a practical application; the proposed model provides a good accuracy in determining the reliability for the crankshaft under mixed mode loading.

Nikabdullah, N. [Department of Mechanical and Materials Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia and Institute of Space Science (ANGKASA), Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia (Malaysia); Singh, S. S. K.; Alebrahim, R.; Azizi, M. A. [Department of Mechanical and Materials Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia (Malaysia); K, Elwaleed A. [Institute of Space Science (ANGKASA), Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia (Malaysia); Noorani, M. S. M. [School of Mathematical Sciences, Faculty of Science and Technology, Universiti Kebangsaan Malaysia (Malaysia)

2014-06-19T23:59:59.000Z

453

Probability of Potential Multi-Canister Overpack Loading System Drop of Proof Load in the K West Basin South Loadout Pit  

SciTech Connect (OSTI)

This document presents the results of a probabilistic analysis of the potential for load drop during the load test of the K West Basin South Loadout Pit Gantry. The calculations are in support of the cask loading system (CLS) subproject load test of the gantry. The purpose of this calculation note is to document the probabilistic calculation of the per lift potential for drop of a test load by the Multi-Canister Overpack (MCO) Loading System (MLS) during load testing at the K West Basin south loadout pit. The MLS subproject needs to load test the MLS in the K West Basin south loadout pit. To perform this test, a basket mockup weighing approximately 4,500 lb (125% of a fully loaded MCO basket accounting for water displacement) needs to be used for one or more load tests. The test load will comprise a standard basket lifting attachment with several ring-shaped steel segments to provide the required weight. The test load will exceed the K Basin Safety Analysis Report (WHC-SD-WM-SAR-062) (SAR) allowances for load drop in the K West Basin south loadout pit. This probabilistic calculation will be used as part of the basis for seeking U.S. Department of Energy approval to use an MLS test weight that exceeds SAR allowances.

SHULTZ, M.V.

2000-01-20T23:59:59.000Z

454

1998 White Book, Pacific Northwest Loads and Resources Study (summary)  

SciTech Connect (OSTI)

The Pacific Northwest Loads and Resources Study (White Book) is published annually by BPA and establishes the planning basis for supplying electricity to customers. It serves a dual purpose. First, the White Book presents projections of regional and Federal system load and resource capabilities, along with relevant definitions and explanations. Second, the White Book serves as a benchmark for annual BPA determinations made pursuant to the 1981 regional power sales contracts.1 Specifically, BPA uses the information in the White Book for determining the notice required when customers request to increase or decrease the amount of power purchased from BPA. The White Book compiles information obtained from several formalized resource planning reports and data submittals, including those from the Northwest Power Planning Council (Council) and the Pacific Northwest Utilities Conference Committee (PNUCC). The White Book is not an operational planning guide, nor is it used for inventory planning to determine BPA revenues. Operation of the Federal Columbia River Power System (FCRPS) is based on a set of criteria different from that used for resource planning decisions. Operational planning is dependent upon real-time or near-term knowledge of system conditions, including expectations of river flows and runoff, market opportunities, availability of reservoir storage, energy exchanges, and other factors affecting the dynamics of operating a power system. The 1998 White Book is presented in two documents: 1) this summary of Federal system and Pacific Northwest region loads and resources; and 2) a technical appendix detailing the loads and resources for each major Pacific Northwest generating utility. This analysis updates the December 1997 Pacific Northwest Loads and Resources Study. The load forecast is derived by using economic planning models to predict the loads that will be placed on electric utilities in the region. This study incorporates information on contract obligations and contract resources, combined with the resource capabilities obtained from public utility and investor-owned utility (IOU) customers through their annual data submittals to the PNUCC, from BPA’s Firm Resource Exhibit (FRE Exhibit 1) submittals, and through analysis of the Federal hydroelectric power system. The 1998 study uses the same economic forecast used for the 1997 study. In this loads and resources study, resource availability is compared with a medium forecast of electricity consumption. The forecasted future electricity demands—firm loads—are subtracted from the projected capability of existing and “contracted for” resources to determine whether BPA and the region will be surplus or deficit. If Federal system resources are greater than loads in any particular year or month, there is a surplus of energy and/or capacity, which BPA may use or market to increase revenues. Conversely, if Federal system firm loads exceed available resources, there is a deficit of energy and/or capacity and BPA would add conservation or contract purchases as needed to meet its firm loads.

none,

1998-12-01T23:59:59.000Z

455

Comparison of Wind Power and Load Forecasting Error Distributions: Preprint  

SciTech Connect (OSTI)

The introduction of large amounts of variable and uncertain power sources, such as wind power, into the electricity grid presents a number of challenges for system operations. One issue involves the uncertainty associated with scheduling power that wind will supply in future timeframes. However, this is not an entirely new challenge; load is also variable and uncertain, and is strongly influenced by weather patterns. In this work we make a comparison between the day-ahead forecasting errors encountered in wind power forecasting and load forecasting. The study examines the distribution of errors from operational forecasting systems in two different Independent System Operator (ISO) regions for both wind power and load forecasts at the day-ahead timeframe. The day-ahead timescale is critical in power system operations because it serves the unit commitment function for slow-starting conventional generators.

Hodge, B. M.; Florita, A.; Orwig, K.; Lew, D.; Milligan, M.

2012-07-01T23:59:59.000Z

456

Parasitic load control system for exhaust temperature control  

DOE Patents [OSTI]

A parasitic load control system is provided. The system may include an exhaust producing engine and a fuel pumping mechanism configured to pressurize fuel in a pressure chamber. The system may also include an injection valve configured to cause fuel pressure to build within the pressure chamber when in a first position and allow injection of fuel from the pressure chamber into one or more combustion chambers of the engine when in a second position. The system may further include a controller configured to independently regulate the pressure in the pressure chamber and the injection of fuel into the one or more combustion chambers, to increase a load on the fuel pumping mechanism, increasing parasitic load on the engine, thereby increasing a temperature of the exhaust produced by the engine.

Strauser, Aaron D. (Washington, IL); Coleman, Gerald N. (Peterborough, GB); Coldren, Dana R. (Fairbury, IL)

2009-04-28T23:59:59.000Z

457

Microchannel cross load array with dense parallel input  

DOE Patents [OSTI]

An architecture or layout for microchannel arrays using T or Cross (+) loading for electrophoresis or other injection and separation chemistry that are performed in microfluidic configurations. This architecture enables a very dense layout of arrays of functionally identical shaped channels and it also solves the problem of simultaneously enabling efficient parallel shapes and biasing of the input wells, waste wells, and bias wells at the input end of the separation columns. One T load architecture uses circular holes with common rows, but not columns, which allows the flow paths for each channel to be identical in shape, using multiple mirror image pieces. Another T load architecture enables the access hole array to be formed on a biaxial, collinear grid suitable for EDM micromachining (square holes), with common rows and columns.

Swierkowski, Stefan P.

2004-04-06T23:59:59.000Z

458

An effective loading method of americium targets in fast reactors  

SciTech Connect (OSTI)

Recently, the development of target fuel with high americium (Am) content has been launched for the reduction of the overall fuel fabrication cost of the minor actinide (MA) recycling. In the framework of the development, this study proposes an effective loading method of Am targets in fast reactors. As a result of parametric survey calculations, we have found the ring-shaped target loading pattern between inner and outer core regions. This loading method is satisfactory both in core characteristics and in MA transmutation property. It should be noted that the Am targets can contribute to the suppression of the core power distribution change due to burnup. The major drawback of Am target is the production of helium gas. A target design modification by increasing the cladding thickness is found to be the most feasible measure to cope with the helium production. (authors)

Ohki, Shigeo; Sato, Isamu; Mizuno, Tomoyasu; Hayashi, Hideyuki; Tanaka, Kenya [Japan Atomic Energy Agency, 4002, Narita-cho, O-arai-machi, Higashi-Ibaraki-gun, Ibaraki 311-1393 (Japan)

2007-07-01T23:59:59.000Z

459

Model for Aggregated Water Heater Load Using Dynamic Bayesian Networks  

SciTech Connect (OSTI)

The transition to the new generation power grid, or “smart grid”, requires novel ways of using and analyzing data collected from the grid infrastructure. Fundamental functionalities like demand response (DR), that the smart grid needs, rely heavily on the ability of the energy providers and distributors to forecast the load behavior of appliances under different DR strategies. This paper presents a new model of aggregated water heater load, based on dynamic Bayesian networks (DBNs). The model has been validated against simulated data from an open source distribution simulation software (GridLAB-D). The results presented in this paper demonstrate that the DBN model accurately tracks the load profile curves of aggregated water heaters under different testing scenarios.

Vlachopoulou, Maria; Chin, George; Fuller, Jason C.; Lu, Shuai; Kalsi, Karanjit

2012-07-19T23:59:59.000Z

460

Information technology and innovative drainage management practices for selenium load reduction from irrigated agriculture to provide stakeholder assurances and meet contaminant mass loading policy objectives  

SciTech Connect (OSTI)

Many perceive the implementation of environmental regulatory policy, especially concerning non-point source pollution from irrigated agriculture, as being less efficient in the United States than in many other countries. This is partly a result of the stakeholder involvement process but is also a reflection of the inability to make effective use of Environmental Decision Support Systems (EDSS) to facilitate technical information exchange with stakeholders and to provide a forum for innovative ideas for controlling non-point source pollutant loading. This paper describes one of the success stories where a standardized Environmental Protection Agency (EPA) methodology was modified to better suit regulation of a trace element in agricultural subsurface drainage and information technology was developed to help guide stakeholders, provide assurances to the public and encourage innovation while improving compliance with State water quality objectives. The geographic focus of the paper is the western San Joaquin Valley where, in 1985, evapoconcentration of selenium in agricultural subsurface drainage water, diverted into large ponds within a federal wildlife refuge, caused teratogenecity in waterfowl embryos and in other sensitive wildlife species. The fallout from this environmental disaster was a concerted attempt by State and Federal water agencies to regulate non-point source loads of the trace element selenium. The complexity of selenium hydrogeochemistry, the difficulty and expense of selenium concentration monitoring and political discord between agricultural and environmental interests created challenges to the regulation process. Innovative policy and institutional constructs, supported by environmental monitoring and the web-based data management and dissemination systems, provided essential decision support, created opportunities for adaptive management and ultimately contributed to project success. The paper provides a retrospective on the contentious planning process and offers suggestions as to how the technical and institutional issues could have been resolved faster through early adoption of some of the core principles of sound EDSS design.

Quinn, N.W.T.

2009-10-15T23:59:59.000Z

Note: This page contains sample records for the topic "load three-junction concentrator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Plastic instabilities in statically and dynamically loaded spherical vessels  

SciTech Connect (OSTI)

Significant changes were made in design limits for pressurized vessels in the 2007 version of the ASME Code (Section VIII, Div. 3) and 2008 and 2009 Addenda. There is now a local damage-mechanics based strain-exhaustion limit as well as the well-known global plastic collapse limit. Moreover, Code Case 2564 (Section VIII, Div. 3) has recently been approved to address impulsively loaded vessels. It is the purpose of this paper to investigate the plastic collapse limit as it applies to dynamically loaded spherical vessels. Plastic instabilities that could potentially develop in spherical shells under symmetric loading conditions are examined for a variety of plastic constitutive relations. First, a literature survey of both static and dynamic instabilities associated with spherical shells is presented. Then, a general plastic instability condition for spherical shells subjected to displacement controlled and impulsive loading is given. This instability condition is evaluated for six plastic and visco-plastic constitutive relations. The role of strain-rate sensitivity on the instability point is investigated. Calculations for statically and dynamically loaded spherical shells are presented, illustrating the formation of instabilities as well as the role of imperfections. Conclusions of this work are that there are two fundamental types of instabilities associated with failure of spherical shells. In the case of impulsively loaded vessels, where the pulse duration is short compared to the fundamental period of the structure, one instability type is found not to occur in the absence of static internal pressure. Moreover, it is found that the specific role of strain-rate sensitivity on the instability strain depends on the form of the constitutive relation assumed.

Duffey, Thomas A [Los Alamos National Laboratory; Rodriguez, Edward A [Los Alamos National Laboratory

2010-01-01T23:59:59.000Z

462

Intracellular transactivation of HIV can account for the decelerating decay of virus load during drug therapy  

E-Print Network [OSTI]

between an activated and latent state results in the typical decelerating decay of virus load following

Utrecht, Universiteit

463

A Comparison of Load Balancing Algorithms for AMR Qingyu Meng, Justin Luitjens, Martin Berzins  

E-Print Network [OSTI]

that we implemented a better new space-curve filling load balancing algorithm comparing to Zoltan Load1 A Comparison of Load Balancing Algorithms for AMR in Uintah Qingyu Meng, Justin Luitjens, Martin 84112 USA October 27, 2008 Abstract: This technical report discussed load balancing algorithms for AMR

Utah, University of

464

Failure Modes of Vacuum Plasma Spray Tungsten Coating Created on Carbon Fibre Composites under Thermal Loads  

E-Print Network [OSTI]

Failure Modes of Vacuum Plasma Spray Tungsten Coating Created on Carbon Fibre Composites under Thermal Loads

465

Prediction of Air Conditioning Load Response for Providing Spinning Reserve - ORNL Report  

SciTech Connect (OSTI)

This report assesses the use of air conditioning load for providing spinning reserve and discusses the barriers and opportunities. Air conditioning load is well suited for this service because it often increases during heavy load periods and can be curtailed for short periods with little impact to the customer. The report also provides an appendix describing the ambient temperature effect on air conditioning load.

Kueck, John D [ORNL; Kirby, Brendan J [ORNL; Ally, Moonis Raza [ORNL; Rice, C Keith [ORNL

2009-02-01T23:59:59.000Z

466

A Generalized Battery Model of a Collection of Thermostatically Controlled Loads for Providing Ancillary Service  

E-Print Network [OSTI]

. Residential Thermostatically Controlled Loads (TCLs) such as air conditioner, heat pump, water heater, and re

Sanandaji, Borhan M.

467

A hardware-based approach to adaptive load-sharing on a local area network  

E-Print Network [OSTI]

Load-distribution is used to enhance the performance of distributed systems. Two types of load-distribution techniques have been studied and used: load-sharing schemes, in which the total load on the system is distributed in such a way...

Reddy, Harikrishna M

1994-01-01T23:59:59.000Z

468

Framework for Coupling Room Air Models to Heat Balance Model Load and Energy Calculations (RP-1222)  

E-Print Network [OSTI]

1 Framework for Coupling Room Air Models to Heat Balance Model Load and Energy Calculations (RP in a program for hourly load calculations of a single thermal zone. The heat balance model for load and energy to heat balance model load and energy calculations," HVAC&R Research, 10(2), 91-111. #12;2 · Mixed

Chen, Qingyan "Yan"

469

Resource Adequacy Load Forecast A Report to the Resource Adequacy Advisory Committee  

E-Print Network [OSTI]

one hour peak demand and monthly energy assuming normal weather. The Council forecast includes loadsResource Adequacy Load Forecast A Report to the Resource Adequacy Advisory Committee Tomás of the assessment is the load forecast. The Council staff has recently developed a load forecast to be used

470

Photoionisation loading of large Sr+ ion clouds with ultrafast pulses  

E-Print Network [OSTI]

This paper reports on photoionisation loading based on ultrafast pulses of singly-ionised strontium ions in a linear Paul trap. We take advantage of an autoionising resonance of Sr neutral atoms to form Sr+ by two-photon absorption of femtosecond pulses at a wavelength of 431nm. We compare this technique to electron-bombardment ionisation and observe several advantages of photoionisation. It actually allows the loading of a pure Sr+ ion cloud in a low radio-frequency voltage amplitude regime. In these conditions up to 4x10^4 laser-cooled Sr+ ions were trapped.

Sébastien Removille; Romain Dubessy; Quentin Glorieux; Samuel Guibal; Thomas Coudreau; Luca Guidoni; Jean-Pierre Likforman

2008-12-05T23:59:59.000Z

471

Inductrack III configuration--a maglev system for high loads  

DOE Patents [OSTI]

Inductrack III configurations are suited for use in transporting heavy freight loads. Inductrack III addresses a problem associated with the cantilevered track of the Inductrack II configuration. The use of a cantilevered track could present mechanical design problems in attempting to achieve a strong enough track system such that it would be capable of supporting very heavy loads. In Inductrack III, the levitating portion of the track can be supported uniformly from below, as the levitating Halbach array used on the moving vehicle is a single-sided one, thus does not require the cantilevered track as employed in Inductrack II.

Post, Richard F

2013-11-12T23:59:59.000Z

472

Lateral load test of a drilled shaft in clay  

E-Print Network [OSTI]

LATERAL LOAD TEST OF A DRILLED SHAFT IN CLAY A Thesis by VERNON RAY KASCH Submitted to the Graduate College of Texas A8M University in partial fulfillment of the requirement for the degree of MASTER OF SCIENCE December 1977 Major Subject...: Civil Engineering LATERAL LOAD TEST OF A DRILLED SHAFT IN CLAY A Thesis by VERNON RAY KASCH Approved as to style and content by: Harry M. Coyle - Ch irman of Committee Charles H. Samson, Jr. Head of Department Wayne . Dunlap - Ne er Christop er C...

Kasch, Vernon R

1977-01-01T23:59:59.000Z

473

Direct versus Facility Centric Load Control for Automated Demand Response  

SciTech Connect (OSTI)

Direct load control (DLC) refers to the scenario where third party entities outside the home or facility are responsible for deciding how and when specific customer loads will be controlled in response to Demand Response (DR) events on the electric grid. Examples of third parties responsible for performing DLC may be Utilities, Independent System Operators (ISO), Aggregators, or third party control companies. DLC can be contrasted with facility centric load control (FCLC) where the decisions for how loads are controlled are made entirely within the facility or enterprise control systems. In FCLC the facility owner has more freedom of choice in how to respond to DR events on the grid. Both approaches are in use today in automation of DR and both will continue to be used in future market segments including industrial, commercial and residential facilities. This paper will present a framework which can be used to differentiate between DLC and FCLC based upon where decisions are made on how specific loads are controlled in response to DR events. This differentiation is then used to compare and contrast the differences between DLC and FCLC to identify the impact each has on:(1)Utility/ISO and third party systems for managing demand response, (2)Facility systems for implementing load control, (3)Communications networks for interacting with the facility and (4)Facility operators and managers. Finally a survey of some of the existing DR related specifications and communications standards is given and their applicability to DLC or FCLC. In general FCLC adds more cost and responsibilities to the facilities whereas DLC represents higher costs and complexity for the Utility/ISO. This difference is primarily due to where the DR Logic is implemented and the consequences that creates. DLC may be more certain than FCLC because it is more predictable - however as more loads have the capability to respond to DR signals, people may prefer to have their own control of end-use loads and FCLC systems. Research is needed to understand the predictability of FCLC which is related to the perceived value of the DR from the facility manager or home owner's perspective.

Koch, Ed; Piette, Mary Ann

2009-11-06T23:59:59.000Z

474

Load frequency control of interconnected power systems with system constraints  

E-Print Network [OSTI]

Responses D. Generating Unit Characteristics E. The State Variable Representation of the Dynamic F. LFC System Data . 1. Power System Data 2. Controller Gains 3. The Reheat-turbine Prime-Mover Data Model . 6 7 8 10 11 12 15 15 18 23 23 25... 56 25 LFC system response with VSS control. Area 1 fails to respond for a load change of APnr ? 0, 01 p. u. 57 26 LFC system response with conventional controL Area 1 fails to respond for the same load disturbance as in Fig. 26. . . 58 27...

Choudhury, Md Ershadul H

1993-01-01T23:59:59.000Z

475

Flammability limits of dusts: Minimum inerting concentrations  

SciTech Connect (OSTI)

A new flammability limit parameter has been defined as the Minimum Inerting Concentration (MIC). This is the concentration of inertant required to prevent a dust explosion regardless of fuel concentration. Previous experimental work at Fike in a 1-m{sup 3} spherical chamber has shown this flammability limit to exist for pulverized coal dust and cornstarch. In the current work, inerting experiments with aluminum, anthraquinone and polyethylene dusts as fuels were performed, using monoammonium phosphate and sodium bicarbonate as inertants. The results show that an MIC exists only for anthraquinone inerted with sodium bicarbonate. The other combustible dust and inertant mixtures did not show a definitive MIC, although they did show a strong dependence between inerting level and suspended fuel concentration. As the fuel concentration increased, the amount of inertant required to prevent an explosion decreased. Even though a definitive MIC was not found for most of the dusts an effective MIC can be estimated from the data. The use of MIC data can aid in the design of explosion suppression schemes.

Dastidar, A.G.; Amyotte, P.R. [Dalhousie Univ., Halifax, Nova Scotia (Canada). Dept. of Chemical Engineering] [Dalhousie Univ., Halifax, Nova Scotia (Canada). Dept. of Chemical Engineering; Going, J.; Chatrathi, K. [Fike Corp., Blue Springs, MO (United States)] [Fike Corp., Blue Springs, MO (United States)

1999-05-01T23:59:59.000Z

476

Spinning Reserve From Hotel Load Response: Initial Progress  

SciTech Connect (OSTI)

This project was motivated by the fundamental match between hotel space conditioning load response capability and power system contingency response needs. As power system costs rise and capacity is strained demand response can provide a significant system reliability benefit at a potentially attractive cost. At ORNL s suggestion, Digital Solutions Inc. adapted its hotel air conditioning control technology to supply power system spinning reserve. This energy saving technology is primarily designed to provide the hotel operator with the ability to control individual room temperature set-points based upon occupancy (25% to 50% energy savings based on an earlier study [Kirby and Ally, 2002]). DSI added instantaneous local load shedding capability in response to power system frequency and centrally dispatched load shedding capability in response to power system operator command. The 162 room Music Road Hotel in Pigeon Forge Tennessee agreed to host the spinning reserve test. The Tennessee Valley Authority supplied real-time metering equipment in the form of an internet connected Dranetz-BMI power quality meter and monitoring expertise to record total hotel load during both normal operations and test results. The Sevier County Electric System installed the metering. Preliminary testing showed that hotel load can be curtailed by 22% to 37% depending on the outdoor temperature and the time of day. These results are prior to implementing control over the common area air conditioning loads. Testing was also not at times of highest system or hotel loading. Full response occurred in 12 to 60 seconds from when the system operator s command to shed load was issued. The load drop was very rapid, essentially as fast as the 2 second metering could detect, with all units responding essentially simultaneously. Load restoration was ramped back in over several minutes. The restoration ramp can be adjusted to the power system needs. Frequency response testing was not completed. Initial testing showed that the units respond very quickly. Problems with local power quality generated false low frequency signals which required testing to be stopped. This should not be a problem in actual operation since the frequency trip points will be staggered to generate a droop curve which mimics generator governor response. The actual trip frequencies will also be low enough to avoid power quality problems. The actual trip frequencies are too low to generate test events with sufficient regularity to complete testing in a reasonable amount of time. Frequency response testing will resume once the local power quality problem is fully understood and reasonable test frequency settings can be determined. Overall the preliminary testing was extremely successful. The hotel response capability matches the power system reliability need, being faster than generation response and inherently available when the power system is under the most stress (times of high system and hotel load). Periodic testing is scheduled throughout the winter and spring to characterize hotel response capability under a full range of conditions. More extensive testing will resume when summer outdoor temperatures are again high enough to fully test hotel response.

Kueck, John D [ORNL; Kirby, Brendan J [ORNL

2008-11-01T23:59:59.000Z

477

Wide range radioactive gas concentration detector  

DOE Patents [OSTI]

A wide range radioactive gas concentration detector and monitor which is capable of measuring radioactive gas concentrations over a range of eight orders of magnitude. The device of the present invention is designed to have an ionization chamber which is sufficiently small to give a fast response time for measuring radioactive gases but sufficiently large to provide accurate readings at low concentration levels. Closely spaced parallel plate grids provide a uniform electric field in the active region to improve the accuracy of measurements and reduce ion migration time so as to virtually eliminate errors due to ion recombination. The parallel plate grids are fabricated with a minimal surface area to reduce the effects of contamination resulting from absorption of contaminating materials on the surface of the grids. Additionally, the ionization chamber wall is spaced a sufficient distance from the active region of the ionization chamber to minimize contamination effects.

Anderson, David F. (Los Alamos, NM)

1984-01-01T23:59:59.000Z

478

A molecular dynamics investigation of the unusual concentration dependencies of Fick diffusivities in silica mesopores  

SciTech Connect (OSTI)

Molecular Dynamics (MD) simulations were carried out to determine the self-diffusivitiy, D{sub i,self}, the Maxwell–Stefan diffusivity, Đ{sub i}, and the Fick diffusivity, D{sub i}, for methane (C1), ethane (C2), propane (C3), n-butane (nC4), n-pentane (nC5), n-hexane (nC6), n-heptane (nC7), and cyclohexane (cC6) in cylindrical silica mesopores for a range of pore concentrations. The MD simulations show that zero-loading diffusivity Đ{sub i}(0) is consistently lower, by up to a factor of 20, than the values anticipated by the classical Knudsen formula. The concentration dependence of the Fick diffusivity, D{sub i} is found to be unusually complex, and displays a strong minimum in some cases; this characteristic can be traced to molecular clustering.

Krishna, Rajamani; van Baten, Jasper M

2011-01-01T23:59:59.000Z

479

Point-focus spectral splitting solar concentrator for multiple cells concentrating photovoltaic system  

E-Print Network [OSTI]

In this paper we present and experimentally validate a low-cost design of a spectral splitting concentrator for the efficient conversion of solar energy. The optical device consists of a dispersive prismatic lens made of polycarbonate designed to simultaneously concentrate the solar light and split it into its spectral components. With respect to our previous implementation, this device concentrates the light along two axes and generates a light pattern compatible with the dimensions of a set of concentrating photovoltaic cells while providing a higher concentration ratio. The mathematical framework and the constructive approach used for the design are presented and the device performance is simulated using ray-tracing software. We obtain spectral separation in the visible range within a 3x1 cm2 area and a maximum concentration of 210x for a single wavelength. The device is fabricated by injection molding and its performance is experimentally investigated. We measure an optical transmissivity above 90% in the...

Maragliano, Carlo; Stefancich, Marco

2015-01-01T23:59:59.000Z

480

Measured and predicted rotordynamic coefficients and static performance of a rocker-pivot, tilt pad bearing in load-on-pad and load-between-pad configurations  

E-Print Network [OSTI]

This thesis presents the static and dynamic performance data for a 5 pad tilting pad bearing in both the load-on-pad (LOP) and the load-between-pad (LBP) configurations over a variety of different loads and speeds. The bearing tested was an Orion...

Carter, Clint Ryan

2009-06-02T23:59:59.000Z

Note: This page contains sample records for the topic "load three-junction concentrator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Resonance-shifting luminescent solar concentrators  

DOE Patents [OSTI]

An optical system and method to overcome luminescent solar concentrator inefficiencies by resonance-shifting, in which sharply directed emission from a bi-layer cavity into a glass substrate returns to interact with the cavity off-resonance at each subsequent reflection, significantly reducing reabsorption loss en route to the edges. In one embodiment, the system comprises a luminescent solar concentrator comprising a transparent substrate, a luminescent film having a variable thickness; and a low refractive index layer disposed between the transparent substrate and the luminescent film.

Giebink, Noel Christopher; Wiederrecht, Gary P; Wasielewski, Michael R

2014-09-23T23:59:59.000Z

482

Sandia National Laboratories: Concentrating Solar Power  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsrucLas ConchasPassive SolarEducation Programs:CRFProvide Insight for RotorConcentratingConcentrating

483

Supplying Renewable Energy to Deferrable Loads: Algorithms and Economic Analysis  

E-Print Network [OSTI]

Supplying Renewable Energy to Deferrable Loads: Algorithms and Economic Analysis Anthony compares to price responsive demand in terms capacity gains and energy market revenues for renewable to renewable generation. I. INTRODUCTION Renewable power is emerging as a mainstream source of energy supply

Oren, Shmuel S.

484

Reducing Power Load Fluctuations on Ships Using Power Redistribution Control  

E-Print Network [OSTI]

controller is demonstrated through simulation studies on a supply vessel power plant, using the SIMULINK plant with electric propulsion, the power generation will con- sist of multiple engines, whereReducing Power Load Fluctuations on Ships Using Power Redistribution Control Damir Radan,1 Asgeir J

Johansen, Tor Arne

485

Automatic load follow control system for PWR plants  

SciTech Connect (OSTI)

In Japan, load follow operation (daily load follow, automatic frequency control (AFC) operation, and governor free (GF) operation) of nuclear plants will be required in the near future to control grid frequency, as the ratio of nuclear plant electrical production to total grid production will increase. The AFC operation regulated power by demand from the central load dispatcher to control mainly the fringe component of the grid frequency fluctuation, and GF operation regulates power by turbine revolution or grid frequency to control mainly the cyclic component of grid frequency fluctuation. This paper deals with the automatic power distribution control system, which is important to load follow operation and possibly will be applied to pressurized water reactor (PWR) nuclear plants. The reactor control systems noted below are conventional design with some improvements for AFC/GF operation, so that the reactor operates the turbine as before: (1) rod control system (reactor power control); (2) pressurizer pressure control system; (3) pressurizer level control system; and (4) steam generator level control system.

Nakakura, H.; Ishiguro, A.

1987-01-01T23:59:59.000Z

486

"Evaluating the effects of the loading environment on the mechanical  

E-Print Network [OSTI]

"Evaluating the effects of the loading environment on the mechanical properties of materials embrittling H2 for the hydrogen energy economy, and material embrittlement and fatigue issues in the resurgent nuclear power field, and alloy selection and life prediction for bio-medical engineering. Proper modeling

Acton, Scott

487

A Dual Supply Buck Converter with Improved Light Load Efficiency  

E-Print Network [OSTI]

to reduce the switching loss by reducing the effective input supply voltage at light load. This is achieved by switching between two different input voltages (3.3V and 1.65V) depending on the output current value. Experimental results show...

Chen, Hui

2013-05-02T23:59:59.000Z

488

2006 Haulage & Loading Conference: big equipment, big crowd  

SciTech Connect (OSTI)

The theme of this year's Haulage and Loading Conference was 'Is better still better?' Most of the presenters either considered the effectiveness of bigger equipment or examined other strategies from various perspectives, based on their experiences. Papers were presented on trucks, shovels, loaders, excavators, haul road design and maintenance, and incorporating IT equipment. 5 photos.

NONE

2006-06-15T23:59:59.000Z

489

EXPERIMENTS IN LOAD BALANCING ACROSS THE GRID VIA A CODE  

E-Print Network [OSTI]

EXPERIMENTS IN LOAD BALANCING ACROSS THE GRID VIA A CODE TRANSFORMATION Eric Violard, Romaric David {violard,david,schwarz}@icps.u-strasbg.fr Abstract We propose a code transformation to adapt a parallel MPI to the dependencies scheme it involves. Experimen- tal results show the advantage of our code transformation compared

Genaud, Stéphane

490

WASHLOAD AND FINE SEDIMENT LOAD By Hyoseop S. Woo,1  

E-Print Network [OSTI]

WASHLOAD AND FINE SEDIMENT LOAD By Hyoseop S. Woo,1 Pierre Y. Julien,2 M. ASCE, and Everett V describes it very distinctly. He stated that if the sediment is added to the upstream end of a concrete channel and the channel is swept clean, and the sediment has not left any trace in the channel, its rate

Julien, Pierre Y.

491

ELEMENT C: Management Measures Necessary to Achieve Your Load Reductions,  

E-Print Network [OSTI]

, public education, ordinances, pet waste programs, erosion control plans. Regulatory Tools as Management · Identify new management opportunities · Identify critical areas in watershed where additional measures1 ELEMENT C: Management Measures Necessary to Achieve Your Load Reductions, Along with the Critical

492

Monitoring of Electrical End-Use Loads in Commercial Buildings  

E-Print Network [OSTI]

Southern California Edison is currently conducting a program to collect end-use metered data from commercial buildings in its service area. The data will provide actual measurements of end-use loads and will be used in research and in designing...

Martinez, M.; Alereza, T.; Mort, D.

1988-01-01T23:59:59.000Z

493

Load Management - An Industrial Perspective on This Developing Technology  

E-Print Network [OSTI]

Load Management is a rapidly developing technology which can have a significant impact on all electric users, especially large users. It is mandated by P.U.R.P.A. (Public Utility Regulatory Policy Act) and is akin to energy conservation but its...

Delgado, R. M.

1983-01-01T23:59:59.000Z

494

Building Load Simulation and Validation of an Office Building  

E-Print Network [OSTI]

of the model for electricity use were calibrated to match the actual electricity use for the average year of the available data for years 1998, 1999, and 2000. The monthly and annual cooling loads of the building were calculated by using the DOE2.1E. The extra...

Alghimlas, F.

2002-01-01T23:59:59.000Z

495

Maximizing Efficiency of Solar-Powered Systems by Load Matching  

E-Print Network [OSTI]

energy. However, solar powered sys- tems must also consider the output level of the solar panel for power be counterproductive. Another problem that is of particular importance to solar pan- els is load matching. Solar panels is around 0.7­1.2, solar panels have a much larger Ri value as a function of the solar output and current

Shinozuka, Masanobu

496

Generalized solar load ratio correlation for direct gain buildings  

SciTech Connect (OSTI)

A generalized solar load ratio correlation has been developed for direct gain buildings by generating relationships between the correlation parameters and two fundamental design parameters. The first design parameter is the steady state conductance of the solar aperture, U/sub c/. The second is the effective heat capacity of the solar zone, EHC.

Wray, W.O.; Best, E.D.

1986-01-01T23:59:59.000Z

497

Sandia's research spans generation, storage, and load management at  

E-Print Network [OSTI]

Sandia's research spans generation, storage, and load management at the component and systems kW diesel genset, fuel cells, and additional interchangeable generators. Storage capabilities include a 500 kWh lead-acid battery bank, along with several additional batteries of smaller size. Over

498

Leveraging Load Migration and Basestaion Consolidation for Green Communications in  

E-Print Network [OSTI]

as a useful technology for improving resource utilization and power efficiency. For example, in a virtualized power-efficient BSs in its neighborhood such that idle BSs can be turned off or put into sleep to save power. In this paper, we propose to leverage load migration and BS consolidation for green

Tang, Jian "Neil"

499

Response of Lithium Polymer Batteries to Mechanical Loading  

E-Print Network [OSTI]

Response of Lithium Polymer Batteries to Mechanical Loading Karl Suabedissen1, Christina Peabody2 · Lithium polymer batteries are everywhere. · Efforts to create flexible batteries. · Restrictive battery performance. #12;Lithium Polymer Battery Structure · Al cathode coated with LiCoO2. · Cu anode coated

Petta, Jason

500

Dynamic Load Balancing for the Distributed Mining of Molecular Structures  

E-Print Network [OSTI]

Dynamic Load Balancing for the Distributed Mining of Molecular Structures Giuseppe Di Fatta, Member the data mining community, where algorithms to find frequent graphs have received increasing attention over a distributed approach to the frequent subgraph mining problem to discover interesting patterns in molecular

Berthold, Michael R.