Powered by Deep Web Technologies
Note: This page contains sample records for the topic "load management receiver" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

CBFO Manager Receives ESGR Award  

NLE Websites -- All DOE Office Websites (Extended Search)

U.S. Department of Energy Carlsbad Field Office Waste Isolation Pilot Plant P.O. Box 3090 Carlsbad, New Mexico 88221 For Immediate Release CBFO Manager Receives ESGR Honor...

2

Load-management decision  

Science Conference Proceedings (OSTI)

Utilities require baseload, intermediate, and peaking plants to meet fluctuating customer demand. These can be supplemented with off-peak generation and storage and load management, which can take the form of direct utility control over interruptible and deferrable customers or customer incentives that require off-peak demand. Utilities should make a careful analysis of their load profile, their generation mix, their ability to shift loads, and customer attitudes before deciding on a load-management program that fits their individual needs. They should also be aware that load management is only a limited resource with a number of uncertainties. Research programs into customer relations, system reliability, communications devices, and special control switches and meters will help to relieve some of the uncertainties. (DCK)

Lihach, N.; Gupta, P.

1982-05-01T23:59:59.000Z

3

Analysis of industrial load management  

SciTech Connect

Industrial Load Management, ILM, has increased the possibilities of changing load profiles and raising load factors. This paper reports on load profile measurements and feasible load management applications that could be implemented in industry e.g. bivalent systems for heating of premises and processes, load priority systems, energy storage and rescheduling processes or parts of processes due to differential electricity rates. Industrial load variations on hourly, daily and seasonal basis are treated as well as the impact by load management on load curves e g peak clipping, valley filling and increased off-peak electricity usage.

Bjork, C.O.; Karlsson, B.G.

1986-04-01T23:59:59.000Z

4

EM Field Office Manager Receives Military Honor  

Energy.gov (U.S. Department of Energy (DOE))

EM Carlsbad Field Office (CBFO) Manager Joe Franco receives the Employer Support of the Guard and Reserve (ESGR) Seven Seals Award in June at a ESGR recognition event in Carlsbad, N.M.

5

Load Management: Opportunity or Calamity?  

E-Print Network (OSTI)

After the change in the economics of generating electricity which took place in 1973, many utilities are examining options to hold down their costs. One fact which is clear is that the difference between peak and off peak generating costs is much larger now than prior to 1973. Utilities are examining two options which can be termed load management. One option is to control discretionary loads during peak periods. Cycling of residential water heaters or shutting off industrial electric furnaces during peak periods are both examples of load control which lower the costs borne by the utility. The other option is the use of seasonal surcharges or time-of-day rates to induce customers to alter their usage patterns. Both these load management options focus on reducing utility costs overall without regard to the cost to the consumers affected by the load management options. The issue, then, is whether industrial customers can find opportunities to lower their costs under load management.

Males, R.; Hassig, N.

1981-01-01T23:59:59.000Z

6

Peak load management: Potential options  

SciTech Connect

This report reviews options that may be alternatives to transmission construction (ATT) applicable both generally and at specific locations in the service area of the Bonneville Power Administration (BPA). Some of these options have potential as specific alternatives to the Shelton-Fairmount 230-kV Reinforcement Project, which is the focus of this study. A listing of 31 peak load management (PLM) options is included. Estimated costs and normalized hourly load shapes, corresponding to the respective base load and controlled load cases, are considered for 15 of the above options. A summary page is presented for each of these options, grouped with respect to its applicability in the residential, commercial, industrial, and agricultural sectors. The report contains comments on PLM measures for which load shape management characteristics are not yet available. These comments address the potential relevance of the options and the possible difficulty that may be encountered in characterizing their value should be of interest in this investigation. The report also identifies options that could improve the efficiency of the three customer utility distribution systems supplied by the Shelton-Fairmount Reinforcement Project. Potential cogeneration options in the Olympic Peninsula are also discussed. These discussions focus on the options that appear to be most promising on the Olympic Peninsula. Finally, a short list of options is recommended for investigation in the next phase of this study. 9 refs., 24 tabs.

Englin, J.E.; De Steese, J.G.; Schultz, R.W.; Kellogg, M.A.

1989-10-01T23:59:59.000Z

7

Glossary of terms related to load management  

Science Conference Proceedings (OSTI)

Part I of the Glossary of Terms related to Load Management has been prepared by the Terminology Task Force of the Load Management Subcommittee. The glossary contains many definitions of terms used by the electric utility industry concerning the subject of Load Management. The terms are listed in alphabetical order and cross-referenced where necessary.

Gellings, C.W.

1985-09-01T23:59:59.000Z

8

Load Management - A Better Way  

E-Print Network (OSTI)

Ohio Edison Company serves about 800,000 customers in Ohio and Pennsylvania, making it one of the 20 largest electric utilities in the nation. The 'cost of service' concept has been basic to rate design throughout the history of the company, and is evident today as the demand related charges have escalated in recent rate cases reflecting the higher costs of installing new generating facilities at today's high construction and financing costs. This paper will describe one of the many applications of load management techniques which has enabled the company to shift well over 100,000 kilowatts of customer load from the on-peak period to the off-peak period in the last four to five years. This is helping delay the need for new plants and allows existing plants to be more fully utilized, resulting in lower costs to customers who use their electric service wisely and possibly lower rate increases in the future than would have been required otherwise.

Easley, J. F.

1982-01-01T23:59:59.000Z

9

Building an Electronics Stewardship Team & Receiving Management...  

NLE Websites -- All DOE Office Websites (Extended Search)

Stewardship Team * Sept '06, Kicked off the Process - Visit from Jeff Eagan & Jane Powers - Assembled 7 audiences consisting of upper management from each group and employees...

10

Savannah River Site Contractor Receives Project Management Institute Award  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Contractor Receives Project Management Contractor Receives Project Management Institute Award Savannah River Site Contractor Receives Project Management Institute Award November 15, 2011 - 12:00pm Addthis SRR Bubbler Project Manager Bill Pepper, center, accepts the PMI Project of the Year award from Eloy Saldivar, left, president of the Savannah River Chapter of PMI. DWPF Facility Manager Les Sonnenberg is on the right. SRR Bubbler Project Manager Bill Pepper, center, accepts the PMI Project of the Year award from Eloy Saldivar, left, president of the Savannah River Chapter of PMI. DWPF Facility Manager Les Sonnenberg is on the right. AIKEN, S.C. - The local chapter of the Project Management Institute (PMI) recently honored the Savannah River Site liquid waste contractor with its 2011 Project of the Year award.

11

Savannah River Site Contractor Receives Project Management Institute Award  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Savannah River Site Contractor Receives Project Management Savannah River Site Contractor Receives Project Management Institute Award Savannah River Site Contractor Receives Project Management Institute Award November 15, 2011 - 12:00pm Addthis SRR Bubbler Project Manager Bill Pepper, center, accepts the PMI Project of the Year award from Eloy Saldivar, left, president of the Savannah River Chapter of PMI. DWPF Facility Manager Les Sonnenberg is on the right. SRR Bubbler Project Manager Bill Pepper, center, accepts the PMI Project of the Year award from Eloy Saldivar, left, president of the Savannah River Chapter of PMI. DWPF Facility Manager Les Sonnenberg is on the right. AIKEN, S.C. - The local chapter of the Project Management Institute (PMI) recently honored the Savannah River Site liquid waste contractor with its

12

Definition: Direct Control Load Management | Open Energy Information  

Open Energy Info (EERE)

Control Load Management Jump to: navigation, search Dictionary.png Direct Control Load Management Demand-Side Management that is under the direct control of the system operator....

13

Repository Reference Disposal Concepts and Thermal Load Management...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Repository Reference Disposal Concepts and Thermal Load Management Analysis Repository Reference Disposal Concepts and Thermal Load Management Analysis A disposal concept consists...

14

Definition: Circuit Peak Load Management | Open Energy Information  

Open Energy Info (EERE)

Circuit Peak Load Management Jump to: navigation, search Dictionary.png Circuit Peak Load Management An application utilizing sensors, information processors, communications, and...

15

Status of load management storage demonstrations  

DOE Green Energy (OSTI)

DOE is funding a nationwide demonstration of electric load management through the use of utility-controlled, customer-side thermal energy storage for residential space conditioning. The general concept of the projects was developed with the assistance of a broadly based working group drawn from the utility industry. This paper presents the current status of these demonstrations. Ten demonstrations are underway - five heat storage and five cool storage - using between 30 and 50 near-commercial thermal storage devices. The installations and experimental program are designed to: (1) collect reliable load research data for assessing the impact on the utility system; (2) delineate and solve installation problems; (3) establish maintainability; (4) illuminate customer and utility acceptance; and (5) generate cost data. The results obtained are expected to assist utilities in making local load-management decisions, to assist DOE in establishing priorities for R and D efforts in load management, and to provide objective information related to the electric system impact, energy conservation, and cost-effectiveness of this form of load management.

Long, H M; Mohre, D L

1979-01-01T23:59:59.000Z

16

RECEIVED  

NLE Websites -- All DOE Office Websites (Extended Search)

40 40 ri,if--,r7n11-74"vtl Lit0 tait":,0 RECEIVED FFII 2 8 S96 OSTI The Winds of (Evolutionary) Change: Breathing New Life into Microbiology Gary J. Olsen,* Carl R. Woese,* and Ross A. Overbeekt DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsi- bility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Refer- ence herein to any specific commercial product, process, or service by trade name, trademark,

17

G&T adds versatile load management system  

SciTech Connect

Wolverine`s load management system was designed in response to the need to reduce peak demand. The Energy Management System (EMS) prepares short term (seven day) load forecasts, based on a daily peak demand forecst, augmented by a similar day profile based on weather conditions. The software combines the similar day profile with the daily peak demand forecast to yield an hourly load forecast for an entire week. The software uses the accepted load forecast case in many application functions, including interchange scheduling, unit commitment, and transaction evaluation. In real time, the computer updates the accepted forecast hourly, based in actual changes in the weather and load. The load management program executes hourly. The program uses impact curves to calculate a load management strategy that reduces the load forecast below a desired load threshold.

Nickel, J.R.; Baker, E.D.; Holt, J.W.; Chan, M.L.

1995-04-01T23:59:59.000Z

18

Electrical Energy Conservation and Load Management - An Industrial User's Viewpoint  

E-Print Network (OSTI)

Conservation of electrical energy and load management can reduce industry's electric bills, conserves natural resources and reduces the need for new generating plants. In recent years, industry has implemented extensive conservation programs. Some load management has been implemented already. Additional load management is possible; however, optimizing it will require close industry and electric utility company cooperation to develop new incentives and rate structures to make it economically attractive. The limitations of existing rate structures and needed improvements are presented.

Jackson, C. E.

1984-01-01T23:59:59.000Z

19

Load management strategies for electric utilities: a production cost simulation  

SciTech Connect

This paper deals with the development and application of a simulation model for analyzing strategies for managing the residential loads of electric utilities. The basic components of the model are (1) a production-cost model, which simulates daily operation of an electric power system; (2) a load model, which disaggregates system loads into appliance loads and other loads; and (3) a comparison model, which compares the production costs and energy consumption needed to meet a particular load profile to the corresponding costs and energy consumption required for another load profile. The profiles in each pair define alternative ways of meeting the same demand. A method for disaggregating load profiles into appliance components is discussed and several alternative strategies for residential load management for a typical northeastern electric utility are formulated. The method is based on an analysis of the composition of electric loads for a number of classes of residential customers in the model utility system. The effect of alternative load management strategies on the entire residential loadcurve is determined by predicting the effects of these strategies on the specific appliance components of the loadcurve. The results of using the model to analyze alternative strategies for residential load management suggest that load management strategies in the residential sector, if adopted by utilities whose operating and load characteristics are similar to those of the system modeled here, must take into account a wide variety of appliances to achieve significant changes in the total load profile. Moreover, the results also suggest that it is not easy to reduce costs significantly through new strategies for managing residential loads only and that, to be worthwhile, cost-reducing strategies will have to encompass many kinds of appliances.

Blair, P.D.

1979-03-01T23:59:59.000Z

20

Managing plug-loads for demand response within buildings  

Science Conference Proceedings (OSTI)

Detailed and accurate energy accounting is an important first step in improving energy efficiency within buildings. Based on this information, building managers can perform active energy management, especially during demand response situations that require ... Keywords: energy management, energy metering, plug-loads management, wireless sensor network

Thomas Weng; Bharathan Balaji; Seemanta Dutta; Rajesh Gupta; Yuvraj Agarwal

2011-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "load management receiver" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Load management and the La Vereda passive solar community  

SciTech Connect

Reviewed are preliminary data available from some of the passive solar homes now operational at the La Vereda subdivision in Santa Fe, New Mexico. The major emphasis is Load Management - an electric utility term pertaining to when and how much energy is used by the customer. A customer's home is considered to be Load Managed when its major demands for electricity occur at times during the day when the utility has surplus generation capacity. For most utilities this surplus occurs during the night and is referred to as the off-peak period. Compared to conventional electric homes, the La Vereda passive solar homes are Naturally Load Managed because most of their backup heating requirements occur during the utility's off-peak period. Naturally Load Managed homes like these allow the backup heating system to operate freely whenever the space needs heat. Load data from six La Vereda homes are compared to similar data from 1) a group of nonsolar super-insulated total electric homes, and 2) the utility's winter system peak day load profile. The comparison verifies the Natural Load Management characteristics of the well-designed passive solar home. The free operation of the backup heating system, especially during cloudy or severe weather, can reduce the Natural Load Management characteristics of the La Verda homes. Is it possible to Force Load Management on a home, regardless of weather conditions and still guarantee that all space heating requirements are satisfied with off-peak energy. One home at La Vereda is discussed that has an experimental Forced Load Management backup heating system designed to use energy only during the utility's off-peak period. Load data from this home is presented and compared to other homes at La Verda.

Pyde, S.E.

1981-01-01T23:59:59.000Z

22

An efficient load model for analyzing demand side management impacts  

SciTech Connect

The main objective of implementing Demand Side Management (DSM) in power systems is to change the utility's load shape--i.e. changes in the time pattern and magnitude of utility's load. Changing the load shape as a result of demand side activities could change the peak load, base load and/or energy demand. Those three variables have to be explicitly modeled into the load curve for properly representing the effects of demand side management. The impact of DSM will be manifested as higher or lower reliability levels. This paper presents an efficient technique to model the system load such that the impact of demand side management on the power system can be easily and accurately evaluated. The proposed technique to model the load duration curve will facilitate the representation of DSM impacts on loss-of-load probability, energy not served and energy consumption. This will provide an analytical method to study the impact of DSM on capacity requirements. So far iterative methods have been applied to study these impacts. The proposed analytical method results in a faster solution with higher accuracy. It takes only 18 seconds on an 80486 PC to solve each case study involving different peak and base loads, and energy use.

Rahman, S.; Rinaldy (Virginia Polytechnic Inst. and State Univ., Blacksburg, VA (United States))

1993-08-01T23:59:59.000Z

23

Success stories will crack utility resistance to load management  

SciTech Connect

Advocates of load management see it as a solution to high fuel prices, better system load factors, and high utility earnings. Opposing views are investigated. It is conceded that both views have merit, but with proper attention to rate design, load management holds out hope for utility and customer alike. Westinghouse studies conclude that load management must be developed on a utility-specific basis. Many utilities are concerned that load management systems will reduce energy consumption and thus revenues. Experiences that utilities have had with radio and ripple control are briefly reviewed. Dr. Irwin Stelzer from the National Economic Research Associates says that, giving the customer the right price signal, the load curve will manipulate itself into the shape the customer wants. He advocates charging each customer precisely what it costs to deliver that customer's energy. It is seen that load management could improve the utility's income, possibly help defer the need for capital additions, and potentially help keep energy costs down. (MCW)

Owens, K.

1977-03-01T23:59:59.000Z

24

Definition: Real-Time Load Measurement And Management | Open Energy  

Open Energy Info (EERE)

Management Management Jump to: navigation, search Dictionary.png Real-Time Load Measurement And Management This function provides real-time measurement of customer consumption and management of load through Advanced Metering Infrastructure (AMI) systems (smart meters, two-way communications) and embedded appliance controllers that help customers make informed energy use decisions via real-time price signals, time-of-use (TOU) rates, and service options.[1] Related Terms advanced metering infrastructure, time-of-use pricing, smart grid References ↑ SmartGrid.gov 'Description of Functions' An in LikeLike UnlikeLike You like this.Sign Up to see what your friends like. line Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Real-Time_Load_Measurement_And_Management&oldid=493115

25

Ursa: Scalable Load and Power Management in Cloud Storage Systems  

Science Conference Proceedings (OSTI)

Enterprise and cloud data centers are comprised of tens of thousands of servers providing petabytes of storage to a large number of users and applications. At such a scale, these storage systems face two key challenges: (1) hot-spots due to the dynamic ... Keywords: Load management, linear programming, optimization, power management, storage

Gae-Won You; Seung-Won Hwang; Navendu Jain

2013-03-01T23:59:59.000Z

26

Repository Reference Disposal Concepts and Thermal Load Management Analysis  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Repository Reference Disposal Concepts and Thermal Load Management Repository Reference Disposal Concepts and Thermal Load Management Analysis Repository Reference Disposal Concepts and Thermal Load Management Analysis A disposal concept consists of three parts: waste inventory (7 waste types examined), geologic setting (e.g., clay/shale, salt, crystalline, other sedimentary), and the engineering concept of operations (range of generic operational concepts examined). Two major categories for waste package emplacement modes are identified: 1) "open" where extended ventilation can remove heat for many years following waste emplacement underground; and 2) "enclosed" modes for clay/shale and salt media where waste packages are emplaced in direct or close contact with natural or engineered materials which may have temperature limits that constrain thermal

27

Repository Reference Disposal Concepts and Thermal Load Management Analysis  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Repository Reference Disposal Concepts and Thermal Load Management Repository Reference Disposal Concepts and Thermal Load Management Analysis Repository Reference Disposal Concepts and Thermal Load Management Analysis A disposal concept consists of three parts: waste inventory (7 waste types examined), geologic setting (e.g., clay/shale, salt, crystalline, other sedimentary), and the engineering concept of operations (range of generic operational concepts examined). Two major categories for waste package emplacement modes are identified: 1) "open" where extended ventilation can remove heat for many years following waste emplacement underground; and 2) "enclosed" modes for clay/shale and salt media where waste packages are emplaced in direct or close contact with natural or engineered materials which may have temperature limits that constrain thermal

28

Market Driven Distributed Energy Storage Requirements for Load Management Applications  

Science Conference Proceedings (OSTI)

Electric energy storage systems are an enabling technology that could help meet the needs of electric utility by managing peak energy demands, helping shift the peak loads to off peak hours and improving the load factor of the electric distribution system. Applications of distributed energy storage systems (DESS) could also provide power quality and reliability benefits to customers and to the electric system. EPRI collaborated with several investor owned utilities to conduct a study to understand the te...

2007-04-18T23:59:59.000Z

29

Electrical load management for the California water system  

DOE Green Energy (OSTI)

To meet its water needs California has developed an extensive system for transporting water from areas with high water runoff to areas with high water demand. This system annually consumes more than 6 billion kilowatt hours (kWh) of electricity for pumping water and produces more than 12 billion kWh/year of hydroelectric power. From the point of view of energy conservation, the optimum operation of the California water supply system would require that pumping be done at night and generation be done during the day. Night pumping would reduce electric power peak load demand and permit the pumps to be supplied with electricity from ''base load'' generating plants. Daytime hydro power generation would augment peak load power generation by fossil-fuel power plants and save fuel. The technical and institutional aspects of this type of electric power load management for water projects are examined for the purpose of explaining some of the actions which might be pursued and to develop recommendations for the California Energy Resources Conservation and Development Commission (ERCDC). The California water supply system is described. A brief description is given of various energy conservation methods, other than load management, that can be used in the management of water resources. An analysis of load management is presented. Three actions for the ERCDC are recommended: the Commission should monitor upcoming power contract negotiations between the utilities and the water projects; it should determine the applicability of the power-pooling provisions of the proposed National Energy Act to water systems; and it should encourage and support detailed studies of load management methods for specific water projects.

Krieg, B.; Lasater, I.; Blumstein, C.

1977-07-01T23:59:59.000Z

30

Grid Friendly Appliances – Load-side Solution for Congestion Management  

SciTech Connect

This paper discusses the effectiveness of deploying grid-friendly{trademark} appliances (GFAs) as a load-side solution for congestion management in a competitive electricity market, with the residential house ventilation and air conditioning (HVAC) load used as an example. A GFA is an appliance that can have a sensor and a controller installed to detect price, voltage, or frequency signals and turn on/off according to certain control logic. By using the congestion price as a signal to shift GFA power consumption from high-price periods to low-price periods to reduce load in load pocket areas, transmission line congestion can be successfully mitigated. The magnitude of GFA load reduction and the location of the GFA resources are critical to relieve congestion on targeted lines while not causing other lines to congest. Simulation results are presented and the impact of implementing price-responsive GFAs on the power grid is also studied.

Lu, Ning; Nguyen, Tony B.

2006-05-21T23:59:59.000Z

31

Locality Aware Dynamic Load Management for Massively Multiplayer Games  

E-Print Network (OSTI)

hot-spot overload for server 6 and shedding to a remote server is the only option. The net effect with a dynamic load management algorithm enables us to better handle transient crowding by adaptively dispersing MMOG pat- terns, such as, player flocking. Flocking is the movement of many players to one area or hot

Amza, Cristiana

32

2012 CERTS LAAR Program Peer Review - Integration and Extension of Direct Load Management of Smart Loads - Anna Scaglioni, UC Davis  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Integration and Extension of Direct Integration and Extension of Direct Load Management of Smart Loads Anna Scaglione, UC Davis GRA: Mahnoosh Alizadeh Project objective  Invent methods to "store" load demand for * Real-time "generation following" * Integration of load reserves as dispatchable assets in the Energy Market  Architecture for virtual "reserves" (queues) of electrical load demand * Watts to Job mapping (analysis)  Captures digitally the service requirements - Equal service type = Equal queue * Job to Watts mapping (synthesis)  Allows to optimally schedule the load profile Major technical accomplishments  Centralized model: Digital Direct Load Scheduling (DDLS) - Year 1-Year 2

33

Critical analysis of European load management practices. Final report for period January--July 1976  

SciTech Connect

Load management has been practiced in Europe for approximately a quarter century. A critical evaluation of the initial objectives and economic justifications for load management given in Europe may help energy policymakers in the U.S. assess the relevance of load management to meeting their current energy goals. Load management was adopted in Europe primarily to promote a growth in energy sales at a rate greater than the increase in capacity requirements. Utilities were able to improve daily load factors during the winter peak period; however, they may not have been successful in maintaining or improving their financial strength through load management. Increased capital and operating expenditures in the generation and distribution systems became necessary as the power system evolved in response to changing load characteristics. Rates charged to customers did not always produce adequate revenues from managed loads to cover the capital and operating costs to supply those loads. Comprehensive studies of the long-term costs and benefits might have prevented some of the load management problems experienced in Europe. Load management was not introduced in Europe to reduce utility production costs, conserve energy or scarce fuels, improve the environment, or influence summer loads. Accordingly, the European experience with load management may not be relevant to energy policymakers in the U.S. who desire to achieve these objectives.

1977-01-01T23:59:59.000Z

34

Waste Receiving and Processing Facility Module 1 Data Management System Software Requirements Specification  

Science Conference Proceedings (OSTI)

This document provides the software requirements for Waste Receiving and Processing (WRAP) Module 1 Data Management System (DMS). The DMS is one of the plant computer systems for the new WRAP 1 facility (Project W-026). The DMS will collect, store and report data required to certify the low level waste (LLW) and transuranic (TRU) waste items processed at WRAP 1 as acceptable for shipment, storage, or disposal.

Brann, E.C. II

1994-09-09T23:59:59.000Z

35

ROLE OF TOXICITY ASSESSMENT AND MONITORING IN MANAGING THE RECOVERY OF A WASTEWATER RECEIVING STREAM  

Science Conference Proceedings (OSTI)

We evaluate the roles of a long-term comprehensive toxicity assessment and monitoring program in management and for ecological recovery of a freshwater receiving stream impacted by industrial discharges and legacy contamination. National Pollution Discharge Elimination Permit (NPDES)-driven whole effluent toxicity (WET) tests using Ceriodaphnia and fathead minnows were conducted for more than twenty years to characterize wastewaters at the US National Nuclear Security Agency s Y-12 National Security Complex in Oak Ridge, Tennessee. Ambient toxicity tests also were conducted to assess water samples from EFPC, the stream receiving the wastewater discharges. The ambient tests were conducted as part of an extensive biological monitoring program that included routine surveys of fish, invertebrate and periphyton communities. WET testing, associated toxicant identification evaluations (TIEs), and ambient toxicity monitoring were instrumental in identifying toxicants and their sources at the Y-12 Complex, guiding modifications to wastewater treatment procedures, and assessing the success of various pollution-abatement actions. Through time, as requirements changed and water quality improved, the toxicity monitoring program became more focused. Ambient testing with Ceriodaphnia and fathead minnow larvae also was supplemented with less-standardized but more-sensitive alternative laboratory and in situ bioassays. The Y-12 Complex biological monitoring experience demonstrates the significant roles effluent and ambient toxicity testing can have in controlling and managing toxic discharges to receiving waters. It also emphasizes the value of supplementing WET and standardized ambient toxicity tests with alternative laboratory and in situ toxicity tests tailored to address specific problems.

Greeley Jr, Mark Stephen [ORNL; Kszos, Lynn A [ORNL; Stewart, Arthur J [ORNL; Smith, John G [ORNL

2011-01-01T23:59:59.000Z

36

Management of the ten-megawatt solar-thermal central-receiver pilot-plant project  

DOE Green Energy (OSTI)

This report deals with inspection (between April and May 1979) of the Ten-Megawatt Solar-Thermal Central-Receiver Pilot-Plant Project being constructed in Barstow, California by the Department of Energy (DOE) and a utility consortium. At the time of inspection the project was behind schedule and over its projected cost. The project was subsequently rescheduled for initial operation by June 1982 at an estimated cost of $139.5 million. Recommendations are included relative to: better utilization of DOE resources; modified date for initial operation; and initiation of independent management audits. Comments to the draft report are appended. (PSB)

Not Available

1980-06-20T23:59:59.000Z

37

Dynamic load management for MMOGs in distributed environments  

Science Conference Proceedings (OSTI)

To support thousands of concurrent players in virtual worlds simulated by contemporary Massively Multiplayer Online Games, most implementations employ static game world partitioning for distributing the load among multiple game server instances. Further, ... Keywords: load balancing, mmogs

Herbert Jordan; Radu Prodan; Vlad Nae; Thomas Fahringer

2010-05-01T23:59:59.000Z

38

Simple models of district heating systems for load and demand side management  

E-Print Network (OSTI)

Simple models of district heating systems for load and demand side management and operational Energiforskningsprogrammet EFP ENS J.nr. 1373/01-0041 December 2004 #12;Simple models of district heating systems for load 87-7475-323-1 #12;Preface The research project "Simple models of district heating systems for load

39

Prototype System for Managing Wholesale Market Exposure to Volatile Retail Load Exposure  

Science Conference Proceedings (OSTI)

This presentation reports on development of a prototype customer exposure management system that combines the Energy Book System's (EBS's) capabilities to represent full-requirement loads with a model to represent those loads as a stochastic process that can be updated as the delivery date approaches. This system will give risk managers the ability to track the successive narrowing of uncertainty in both wholesale power prices and customer loads as the delivery date approaches, and to develop optimal hed...

2003-12-03T23:59:59.000Z

40

ELECTRICAL LOAD MANAGEMENT FOR THE CALIFORNIA WATER SYSTEM  

E-Print Network (OSTI)

of Water Resources. Water Conservation in California. DWRUse ENERGY CONSERVATION Water Conservation Pump Efficienciescussion of load Water Conservation some of these measures in

Krieg, B.

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "load management receiver" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Balanced binary trees for ID management and load balance in distributed hash tables  

Science Conference Proceedings (OSTI)

We present a low-cost, decentralized algorithm for ID management in distributed hash tables (DHTs) managed by a dynamic set of hosts. Each host is assigned an ID in the unit interval [0, 1). At any time, the set of IDs splits the interval into disjoint ... Keywords: DHT, ID management, P2P, binary tree, distributed hash table, load balance, peer to peer

Gurmeet Singh Manku

2004-07-01T23:59:59.000Z

42

1980 survey and evaluation of utility conservation, load management, and solar end-use projects. Volume 3: utility load management projects. Final report  

DOE Green Energy (OSTI)

The results of the 1980 survey of electric utility-sponsored energy conservation, load management, and end-use solar energy conversion projects are described. The work is an expansion of a previous survey and evaluation and has been jointly sponsored by EPRI and DOE through the Oak Ridge National Laboratory. There are three volumes and a summary document. Each volume presents the results of an extensive survey to determine electric utility involvement in customer-side projects related to the particular technology (i.e., conservation, solar, or load management), selected descriptions of utility projects and results, and first-level technical and economic evaluations.

Not Available

1982-01-01T23:59:59.000Z

43

Electrical load management in smart homes using evolutionary algorithms  

Science Conference Proceedings (OSTI)

In this paper, we focus on a real world scenario of energy management of a smart home. External variable signals, reflecting the low voltage grid's state, are used to address the challenge of balancing energy demand and supply. The problem is formulated ... Keywords: energy management, evolutionary algorithms, nonlinear integer program

Florian Allerding; Marc Premm; Pradyumn Kumar Shukla; Hartmut Schmeck

2012-04-01T23:59:59.000Z

44

Load management alternatives to transmission and distribution construction: Toledo-Wren case study  

SciTech Connect

This paper describes the development of a method to predict the feasibility of using load management as an alternative to construction of transmission and distribution capacity. A forecasting model was developed and applied to a particular case. Several problems were identified in the test case, necessitating modification of the model. The authors conclude that the modified version of the model allows accurate assessment of the effects of load management and conservation measures on transmission capacity. 13 figs. (JDH)

Englin, J.E.; Klan, M.S.; Lyke, A.J.; Tawil, J.J.; De Steese, J.G.; Tepel, R.C.

1987-12-01T23:59:59.000Z

45

Integrating load management with supply-side operations - A case study  

SciTech Connect

The main topic of this paper analyses and discusses the operational integration of Load Management operations with co-generation, power-pool purchases/sells and other supply-side options, where the common denominator is the hourly short-run marginal cost. The second topic concerns the operational coordination problem between a generating utility and its retail distributors when both parties use load management. The thirds is the interactive impacts of interruptible sales and other demand-side programs on the distribution load curve. The discussion is based on the operational experiences at Skydkraft, the largest investor-owned utility in Sweden.

Edvinsson, M.J.; Nilsson, M.O.

1987-08-01T23:59:59.000Z

46

Configuration Management Plan for Long Length Contaminated Equipment Receiver and Transport Trailers  

SciTech Connect

Long Length Contaminated Equipment Removal System Receiver Trailers and Transport Trailers require identification and control for the design, requirements and operations baseline documents. This plan serves as those controls for the subject trailers.

DALE, R.N.

2000-12-18T23:59:59.000Z

47

An Innovative Approach Towards National Peak Load Management  

E-Print Network (OSTI)

An innovative approach was developed and implemented in eight governmental buildings to reduce their load during the peak demand hours in summer of 2007. The innovative approach implemented in these buildings included pre-closing treatment (PCT) between 13:00 and 14:00 h and time-of-day control (TDC) after 14:00 h for air conditioning (A/C) and lighting systems. PCT realized an overall reduction of 3.43 MW, a saving of 11.7% of the buildings peak power demand; while TDC realized a total savings of 8.67 MW at 15:00 h, a saving of 30.7% of the buildings peak power demand at that hour. The temperature build up inside the buildings due to PCT and TDC was within the acceptable range, which validated the technical viability of these measures. The implementation of the innovative approach in the eight governmental buildings with a total measured peak demand of 29.3 MW achieved a reduction of 8.89 MW. This power is now available to other users leading to financial savings of $13.5 million for the nation towards the cost of constructing new power plants and distribution network equipment. More importantly, this reduction in peak power demand of well over 30% involved zero or limited expenditure. A nationwide implementation of this innovative approach in all the governmental and institutional buildings is likely to reduce the national peak power demand by 154 MW which amounts to a capital savings of $232 million towards the cost of new power generation equipment and distribution network.

Al-Mulla, A.; Maheshwari, G. P.; Al-Nakib, D.; ElSherbini, A.; Alghimlas, F.; Al-Taqi, H.; Al-Hadban, Y.

2008-10-01T23:59:59.000Z

48

Demand Management Demonstration Project, Stage 5: development of industrial load simulation model. Executive summary. Final report  

SciTech Connect

The purpose of this project was to design, develop, test and document a computer simulation model of electric utility generating costs required to meet industrial power demands and the effects of utility load management on these generating costs. The results showed that the model developed is a well conceived load management testing, marginal costing tool. What if situations can be readily tested to determine their impact on system profile and short run marginal costs. The terms unshaped and shaped refer to customers or system use patterns before and after some load management technique was tested. The total flexibility of the model is only apparent after the user has studied test runs in detail. Hourly marginal costs reveal many unexpected changes as a result of shaping loads. Other unexpected changes due to varying economic dispatch schedules while shaping, illustrate the unprecedental latitude for the user to explore optimum generation and load management combinations. The general concept of the model is depicted in the flow chart on the next page.

1977-04-01T23:59:59.000Z

49

A real-time food safety management system for receiving operations in distribution centers  

Science Conference Proceedings (OSTI)

Food safety plan is being promoted in the food industry by the Hong Kong Government as a preliminary quality control tool. However, it appears to be a challenging task for Distribution Centers (DC) that handles food inventory since most of them are lack ... Keywords: Case-Based Reasoning, Food safety, Operating procedures, RFID, Receiving operations

S. I. Lao; K. L. Choy; G. T. S. Ho; Y. C. Tsim; T. C. Poon; C. K. Cheng

2012-02-01T23:59:59.000Z

50

W-026, Waste Receiving and Processing Facility data management system validation and verification report  

Science Conference Proceedings (OSTI)

This V and V Report includes analysis of two revisions of the DMS [data management system] System Requirements Specification (SRS) and the Preliminary System Design Document (PSDD); the source code for the DMS Communication Module (DMSCOM) messages; the source code for selected DMS Screens, and the code for the BWAS Simulator. BDM Federal analysts used a series of matrices to: compare the requirements in the System Requirements Specification (SRS) to the specifications found in the System Design Document (SDD), to ensure the design supports the business functions, compare the discreet parts of the SDD with each other, to ensure that the design is consistent and cohesive, compare the source code of the DMS Communication Module with the specifications, to ensure that the resultant messages will support the design, compare the source code of selected screens to the specifications to ensure that resultant system screens will support the design, compare the source code of the BWAS simulator with the requirements to interface with DMS messages and data transfers relating to the BWAS operations.

Palmer, M.E.

1997-12-05T23:59:59.000Z

51

Method of energy load management using PCM for heating and cooling of buildings  

DOE Patents (OSTI)

A method is described for energy load management for the heating and cooling of a building. The method involves utilizing a wallboard as a portion of the building, the wallboard containing about 5 to about 30 wt.% phase change material such that melting of the phase change material occurs during a rise in temperature within the building to remove heat from the air, and a solidification of the phase change material occurs during a lowering of the temperature to dispense heat into the air. At the beginning of either of these cooling or heating cycles, the phase change material is preferably ``fully charged``. In preferred installations one type of wallboard is used on the interior surfaces of exterior walls, and another type as the surface on interior walls. The particular PCM is chosen for the desired wall and room temperature of these locations. In addition, load management is achieved by using PCM-containing wallboards that form cavities of the building such that the cavities can be used for the air handling duct and plenum system of the building. Enhanced load management is achieved by using a thermostat with reduced dead band of about the upper half of a normal dead band of over three degrees. In some applications, air circulation at a rate greater than normal convection provides additional comfort. 7 figs.

Stovall, T.K.; Tomlinson, J.J.

1996-03-26T23:59:59.000Z

52

Method of energy load management using PCM for heating and cooling of buildings  

DOE Patents (OSTI)

A method of energy load management for the heating and cooling of a building. The method involves utilizing a wallboard as a portion of the building, the wallboard containing about 5 to about 30 wt. % a phase change material such that melting of the phase change material occurs during a rise in temperature within the building to remove heat from the air, and a solidification of the phase change material occurs during a lowering of the temperature to dispense heat into the air. At the beginning of either of these cooling or heating cycles, the phase change material is preferably "fully charged". In preferred installations one type of wallboard is used on the interior surfaces of exterior walls, and another type as the surface on interior walls. The particular PCM is chosen for the desired wall and room temperature of these locations. In addition, load management is achieved by using PCM-containing wallboard that form cavities of the building such that the cavities can be used for the air handling duct and plenum system of the building. Enhanced load management is achieved by using a thermostat with reduced dead band of about the upper half of a normal dead band of over three degree. In some applications, air circulation at a rate greater than normal convection provides additional comfort.

Stovall, Therese K. (Knoxville, TN); Tomlinson, John J. (Knoxville, TN)

1996-01-01T23:59:59.000Z

53

Utility load management and solar energy. Study background and preliminary market potential analysis  

DOE Green Energy (OSTI)

The large-scale use of electrically assisted solar heating and hot water (solar/electric HHW) systems can have a substantial effect on electric utilities. Under some conditions, peak loads may be increased causing electricity generation costs to rise. However, with appropriate control and thermal storage equipment tied to the HHW system, the timing of the delivery of electricity to the HHW system can be controlled so that it is accomplished during those times of the day when utility supply costs are lowest. In this study various load management schemes for these applications are being investigated to determine their effect on the cost of generating the back-up electric power and on the cost of the required control and storage system. Solar/electric HHW systems are compared to electric-only systems for several utilities and several HHW system designs. The issues underlying the study, the methods of investigation, and the results of the first phase of the study are described. In this phase a preliminary analysis of the maximum market potential for night-time precharge electric-only hot water systems in either utilities was conducted. This analysis indicated that if about 20 to 40 percent of the residential customers used these appliances in a load managed mode, the 10 PM--8 AM valley in the utility load curve would be filled. For combined electric heating and hot water, the corresponding fraction is 6 to 12 percent. It is estimated that in each case, roughly twice the number of residential customers could be accommodated in the valley if solar/electric systems were used instead.

Davitian, H; Bright, R N; Marcuse, W

1978-01-01T23:59:59.000Z

54

Commercial and Industrial Conservation and Load Management Programs at New England Electric  

E-Print Network (OSTI)

New England Electric has initiated, through its three retail subsidiaries, an ambitious load management and conservation program designed to reduce its projected 1991 summer peak by 230 megawatts and save 335,000 megawatthours per year. The effort is directed mainly toward the commercial and industrial classes, which make up 62% of sales. The overall program, called Partners In Energy Planning, includes a performance contracting or modified shared savings program, a lighting subsidy program, a storage cooling program, a standby generation program, residential programs and rate programs. This paper discusses the details of the commercial and industrial programs and why they are being implemented.

Gibson, P. H.

1987-09-01T23:59:59.000Z

55

CALUTRON RECEIVER  

DOE Patents (OSTI)

An improved receiver and receiver mount for calutrons are described. The receiver can be manipulated from outside the tank by a single control to position it with respect to the beam. A door can be operated exteriorly also to prevent undesired portions of the beam from entering the receiver. The receiver has an improved pocket which is more selective in the ions collected. (T.R.H.)

Barnes, S.W.

1959-06-16T23:59:59.000Z

56

Industrial-Load-Shaping: The Practice of and Prospects for Utility/Industry Cooperation to Manage Peak Electricity Demand  

E-Print Network (OSTI)

Load-management programs designed to reduce demand for electricity during peak periods are becoming increasingly important to electric utilities. For a growing number of utilities, however, such peak-reduction programs don't go far enough in the face of new problems and challenges, and hence are proving ineffective or counterproductive. For example, many of a utility's largest customers--especially industrial customers who may be "locked into" seemingly inflexible process activities--have limited ability to respond to load-management programs that employ price signals as a central peak-reduction tool. Moreover, utilities in general are finding that vigorous efforts to reduce electric load can result in underutilization of base-load generating facilities. In these and other instances, "load-shaping," which emphasizes a shift of electric load or demand from peak to off-peak periods and provides for greater customer flexibility, may be a more effective strategy. This paper explains the need for and presents the components of a load-shaping program, and describes Pacific Gas and Electric Company's (PGandE) recent experience in designing and pursuing an industrial-load-shaping program. The paper also outlines important obstacles and opportunities likely to confront other utilities and industrial customers interested in working together to develop such programs.

Bules, D. J.; Rubin, D. E.; Maniates, M. F.

1986-06-01T23:59:59.000Z

57

Puget Sound Area Electric Reliability Plan. Appendix D, Conservation, Load Management and Fuel Switching Analysis : Draft Environmental Impact Statement.  

SciTech Connect

Various conservation, load management, and fuel switching programs were considered as ways to reduce or shift system peak load. These programs operate at the end-use level, such as residential water heat. Figure D-1a shows what electricity consumption for water heat looks like on normal and extreme peak days. Load management programs, such as water heat control, are designed to reduce electricity consumption at the time of system peak. On the coldest day in average winter, system load peaks near 8:00 a.m. In a winter with extremely cold weather, electricity consumption increases fr all hours, and the system peak shifts to later in the morning. System load shapes in the Puget Sound area are shown in Figure D-1b for a normal winter peak day (February 2, 1988) and extreme peak day (February 3, 1989). Peak savings from any program are calculated to be the reduction in loads on the entire system at the hour of system peak. Peak savings for all programs are measured at 8:00 a.m. on a normal peak day and 9:00 a.m. on an extreme peak day. On extremely cold day, some water heat load shifts to much later in the morning, with less load available for shedding at the time of system peak. Models of hourly end-use consumption were constructed to simulate the impact of conservation, land management, and fuel switching programs on electricity consumption. Javelin, a time-series simulating package for personal computers, was chosen for the hourly analysis. Both a base case and a program case were simulated. 15 figs., 7 tabs.

United States. Bonneville Power Administration.

1991-09-01T23:59:59.000Z

58

Review of current Southern California edison load management programs and proposal for a new market-driven, mass-market, demand-response program  

E-Print Network (OSTI)

of the Southern California Edison company. Table of Contentsfor Southern California Edison. LBNL-52408. Appendix A.Current Southern California Edison Load Management Programs

Weller, G.H.

2002-01-01T23:59:59.000Z

59

Active load management with advanced window wall systems: Research and industry perspectives  

SciTech Connect

Advanced window wall systems have the potential to provide demand response by reducing peak electric loads by 20-30% in many commercial buildings through the active control of motorized shading systems, switchable window coatings, operable windows, and ventilated double-skin facade systems. These window strategies involve balancing daylighting and solar heat gains, heat rejection through ventilation, and night-time natural ventilation to achieve space-conditioning and lighting energy use reductions without the negative impacts on occupants associated with other demand responsive (DR) strategies. This paper explores conceptually how advanced window systems fit into the context of active load management programs, which cause customers to directly experience the time-varying costs of their consumption decisions. Technological options are suggested. We present pragmatic criteria that building owners use to determine whether to deploy such strategies. A utility's perspective is given. Industry also provides their perspectives on where the technology is today and what needs to happen to implement such strategies more broadly in the US. While there is significant potential for these advanced window concepts, widespread deployment is unlikely to occur with business-as-usual practice. Technologically, integrated window-lighting-HVAC products are underdeveloped. Implementation is hindered by fragmented labor practices, non-standard communication protocols, and lack of technical expertise. Design tools and information products that quantify energy performance, occupant impacts, reliability, and other pragmatic concerns are not available. Interest within the building industry in sustainability, energy-efficiency, and increased occupant amenity, comfort, and productivity will be the driving factors for these advanced facades in the near term--at least until the dust settles on the deregulated electricity market.

Lee, Eleanor S.; Selkowitz, Stephen E.; Levi, Mark S.; Blanc, Steven L.; McConahey, Erin; McClintock, Maurya; Hakkarainen, Pekka; Sbar, Neil L.; Myser, Michael P.

2002-06-01T23:59:59.000Z

60

Active load management with advanced window wall systems: Research and industry perspectives  

SciTech Connect

Advanced window wall systems have the potential to provide demand response by reducing peak electric loads by 20-30% in many commercial buildings through the active control of motorized shading systems, switchable window coatings, operable windows, and ventilated double-skin facade systems. These window strategies involve balancing daylighting and solar heat gains, heat rejection through ventilation, and night-time natural ventilation to achieve space-conditioning and lighting energy use reductions without the negative impacts on occupants associated with other demand responsive (DR) strategies. This paper explores conceptually how advanced window systems fit into the context of active load management programs, which cause customers to directly experience the time-varying costs of their consumption decisions. Technological options are suggested. We present pragmatic criteria that building owners use to determine whether to deploy such strategies. A utility's perspective is given. Industry also provides their perspectives on where the technology is today and what needs to happen to implement such strategies more broadly in the US. While there is significant potential for these advanced window concepts, widespread deployment is unlikely to occur with business-as-usual practice. Technologically, integrated window-lighting-HVAC products are underdeveloped. Implementation is hindered by fragmented labor practices, non-standard communication protocols, and lack of technical expertise. Design tools and information products that quantify energy performance, occupant impacts, reliability, and other pragmatic concerns are not available. Interest within the building industry in sustainability, energy-efficiency, and increased occupant amenity, comfort, and productivity will be the driving factors for these advanced facades in the near term--at least until the dust settles on the deregulated electricity market.

Lee, Eleanor S.; Selkowitz, Stephen E.; Levi, Mark S.; Blanc, Steven L.; McConahey, Erin; McClintock, Maurya; Hakkarainen, Pekka; Sbar, Neil L.; Myser, Michael P.

2002-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "load management receiver" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

A case study review of technical and technology issues for transition of a utility load management program to provide system reliability resources in restructured electricity markets  

SciTech Connect

Utility load management programs--including direct load control and interruptible load programs--were employed by utilities in the past as system reliability resources. With electricity industry restructuring, the context for these programs has changed; the market that was once controlled by vertically integrated utilities has become competitive, raising the question: can existing load management programs be modified so that they can effectively participate in competitive energy markets? In the short run, modified and/or improved operation of load management programs may be the most effective form of demand-side response available to the electricity system today. However, in light of recent technological advances in metering, communication, and load control, utility load management programs must be carefully reviewed in order to determine appropriate investments to support this transition. This report investigates the feasibility of and options for modifying an existing utility load management system so that it might provide reliability services (i.e. ancillary services) in the competitive markets that have resulted from electricity industry restructuring. The report is a case study of Southern California Edison's (SCE) load management programs. SCE was chosen because it operates one of the largest load management programs in the country and it operates them within a competitive wholesale electricity market. The report describes a wide range of existing and soon-to-be-available communication, control, and metering technologies that could be used to facilitate the evolution of SCE's load management programs and systems to provision of reliability services. The fundamental finding of this report is that, with modifications, SCE's load management infrastructure could be transitioned to provide critical ancillary services in competitive electricity markets, employing currently or soon-to-be available load control technologies.

Weller, G.H.

2001-07-15T23:59:59.000Z

62

Electrical Power Savings in Pump and Compressor Networks via Load Management  

E-Print Network (OSTI)

Large industrial plants commonly use multiple parallel units in pump and compressor networks for improved reliability. Sometimes, installed equipment capacity can far exceed actual requirements. This excess capacity can be translated into energy cost savings through “optimum load management”. A key decision parameter in determining the operating policy is the Trigger Point at which to switch from N units to N+1, and vice versa. The Trigger Point is defined as the actual flow rate at which the switching is made to the “ideal” (generally maximum) flow rate at which the switching should be made. At the plant under study, the implicit Trigger Point was generally found to be around 85%, probably because this made it easy to have a smooth transition during the switching operation. A number of pumping and compression networks were analyzed to determine what the potential savings would be if this trigger point were increased to 90 or 95%. The savings potential was found to range from 0 to 23%, with an average of 4.4%. Our study demonstrated that by tightening up operating policies to make sure that the minimum number of machines is being run, significant cost savings are possible with zero capital investment, and negligible sacrifice in operating flexibility or reliability. This paper describes the methodology used, as well as representative results from our study.

Kumana, J. D.; Aseeri, A. S.

2005-01-01T23:59:59.000Z

63

California load management research 1977: a first year report to the Federal Energy Administration on the FEA/California Electric Utilities Demonstration Project. Annual report for 1977  

SciTech Connect

The California Electric Utilities Demonstration Project (EUDP) seeks to identify cost effective ways to implement load management. The three-year, six-million-dollar project will involve 24 field experiments, four electric utilities, and 7000 residential, commercial and industrial utility customers. Each experiment tries to measure how the tested management measure reduces system peak demand and shifts kilowatt-hour use in both customer and system load curves. Results of three experiments are given. The four participating utilities (Southern California Edison, Pacific Gas and Electric, Sacramento Municipal Utility District, and San Diego Gas and Electric) are described. A load curve data catalog is discussed. An appendix to the report shows how to select load management equipment. Another discusses both United States and European load management experiences.

Hairston, R.

1977-10-01T23:59:59.000Z

64

Application of Sleeper Cab Thermal Management Technologies to Reduce Idle Climate Control Loads in Long-Haul Trucks  

DOE Green Energy (OSTI)

Each intercity long-haul truck in the U.S. idles approximately 1,800 hrs per year, primarily for sleeper cab hotel loads. Including workday idling, over 2 billion gallons of fuel are used annually for truck idling. NREL's CoolCab project works closely with industry to design efficient thermal management systems for long-haul trucks that keep the cab comfortable with minimized engine idling and fuel use. The impact of thermal load reduction technologies on idle reduction systems were characterized by conducting thermal soak tests, overall heat transfer tests, and 10-hour rest period A/C tests. Technologies evaluated include advanced insulation packages, a solar reflective film applied to the vehicle's opaque exterior surfaces, a truck featuring both film and insulation, and a battery-powered A/C system. Opportunities were identified to reduce heating and cooling loads for long-haul truck idling by 36% and 34%, respectively, which yielded a 23% reduction in battery pack capacity of the idle-reduction system. Data were also collected for development and validation of a CoolCalc HVAC truck cab model. CoolCalc is an easy-to-use, simplified, physics-based HVAC load estimation tool that requires no meshing, has flexible geometry, excludes unnecessary detail, and is less time-intensive than more detailed computer-aided engineering modeling approaches.

Lustbader, J. A.; Venson, T.; Adelman, S.; Dehart, C.; Yeakel, S.; Castillo, M. S.

2012-10-01T23:59:59.000Z

65

Effects of overstory composition and prescribed fire on fuel loading across a heterogeneous managed landscape in the southeastern USA.  

Science Conference Proceedings (OSTI)

In the southeastern USA, land use history, forest management and natural geomorphic features have created heterogeneous fuel loads. This apparent temporal and spatial variation in fuel loads make it difficult to reliably assess potential fire behavior from remotely sensed canopy variables to determine risk and to prescribe treatments. We examined this variation by exploring the relationships between overstory forest vegetation attributes, recent fire history, and selected surface fuel components across an 80,000 ha contiguous landscape. Measurements of dead and live vegetation components of surface fuels were obtained from 624 permanent plots, or about 1 plot per 100 ha of forest cover. Within forest vegetation groups, we modeled the relationship between individual surface fuel components and overstory stand age, basal area, site quality and recent fire history, then stochastically predicted fuel loads across the landscape using the same linkage variables. The fraction of the plot variation, i.e., R2, explained by predictive models for individual fuel components ranged from 0.05 to 0.66 for dead fuels and 0.03 to 0.97 for live fuels in pine dominated vegetation groups. Stand age and basal area were generally more important than recent fire history for predicting fuel loads. Mapped fuel loads using these regressor variables showed a very heterogeneous landscape even at the scale of a few square kilometers. The mapped patterns corresponded to stand based forest management disturbances that are reflected in age, basal area, and fire history. Recent fire history was significant in explaining variation in litter and duff biomass. Stand basal area was positively and consistently related to dead fuel biomass in most groups and was present in many predictive equations. Patterns in live fuel biomass were related to recent fire history, but the patterns were not consistent among forest vegetation groups. Age and basal area were related to live fuels in a complex manner that is likely confounded with periodic disturbances that disrupt stand dynamics. This study complements earlier hazardous fuels research in the southeastern USA, and indicates that succession, disturbance, site quality and decomposition interact with forest management practices to create variable spatial and temporal conditions. The inclusion of additional land use, disturbance history, and soil-topographic variables coupled to improved sampling methods may increase precision and subsequent fuel mapping.

Parresol, Bernard, R.; Scott, Joe, H.; Andreu, Anne; Prichard, Susan; Kurth, Laurie

2012-01-01T23:59:59.000Z

66

Wind Energy Management System EMS Integration Project: Incorporating Wind Generation and Load Forecast Uncertainties into Power Grid Operations  

SciTech Connect

The power system balancing process, which includes the scheduling, real time dispatch (load following) and regulation processes, is traditionally based on deterministic models. Since the conventional generation needs time to be committed and dispatched to a desired megawatt level, the scheduling and load following processes use load and wind and solar power production forecasts to achieve future balance between the conventional generation and energy storage on the one side, and system load, intermittent resources (such as wind and solar generation), and scheduled interchange on the other side. Although in real life the forecasting procedures imply some uncertainty around the load and wind/solar forecasts (caused by forecast errors), only their mean values are actually used in the generation dispatch and commitment procedures. Since the actual load and intermittent generation can deviate from their forecasts, it becomes increasingly unclear (especially, with the increasing penetration of renewable resources) whether the system would be actually able to meet the conventional generation requirements within the look-ahead horizon, what the additional balancing efforts would be needed as we get closer to the real time, and what additional costs would be incurred by those needs. To improve the system control performance characteristics, maintain system reliability, and minimize expenses related to the system balancing functions, it becomes necessary to incorporate the predicted uncertainty ranges into the scheduling, load following, and, in some extent, into the regulation processes. It is also important to address the uncertainty problem comprehensively by including all sources of uncertainty (load, intermittent generation, generators’ forced outages, etc.) into consideration. All aspects of uncertainty such as the imbalance size (which is the same as capacity needed to mitigate the imbalance) and generation ramping requirement must be taken into account. The latter unique features make this work a significant step forward toward the objective of incorporating of wind, solar, load, and other uncertainties into power system operations. Currently, uncertainties associated with wind and load forecasts, as well as uncertainties associated with random generator outages and unexpected disconnection of supply lines, are not taken into account in power grid operation. Thus, operators have little means to weigh the likelihood and magnitude of upcoming events of power imbalance. In this project, funded by the U.S. Department of Energy (DOE), a framework has been developed for incorporating uncertainties associated with wind and load forecast errors, unpredicted ramps, and forced generation disconnections into the energy management system (EMS) as well as generation dispatch and commitment applications. A new approach to evaluate the uncertainty ranges for the required generation performance envelope including balancing capacity, ramping capability, and ramp duration has been proposed. The approach includes three stages: forecast and actual data acquisition, statistical analysis of retrospective information, and prediction of future grid balancing requirements for specified time horizons and confidence levels. Assessment of the capacity and ramping requirements is performed using a specially developed probabilistic algorithm based on a histogram analysis, incorporating all sources of uncertainties of both continuous (wind and load forecast errors) and discrete (forced generator outages and start-up failures) nature. A new method called the “flying brick” technique has been developed to evaluate the look-ahead required generation performance envelope for the worst case scenario within a user-specified confidence level. A self-validation algorithm has been developed to validate the accuracy of the confidence intervals.

Makarov, Yuri V.; Huang, Zhenyu; Etingov, Pavel V.; Ma, Jian; Guttromson, Ross T.; Subbarao, Krishnappa; Chakrabarti, Bhujanga B.

2010-01-01T23:59:59.000Z

67

Enhancement of Watershed Analysis Risk Management Framework (WARMF) for Mercury Watershed Management and Total Maximum Daily Loads (TMDLs)  

Science Conference Proceedings (OSTI)

This report documents the enhancement of EPRI's Watershed Analysis Risk Management Framework (WARMF) to enable it to simulate the biogeochemical cycling and fish accumulation of mercury in the environment. This report should be of value to the power sector, industry, environmental organizations, government, and public agencies concerned about environmental mercury.

2006-03-13T23:59:59.000Z

68

Reducing data center energy consumption via coordinated cooling and load management  

Science Conference Proceedings (OSTI)

This paper presents a unified approach to data center energy management based on a modeling framework that characterizes the influence of key decision variables on computational performance, thermal generation, and power consumption. Temperature dynamics ...

Luca Parolini; Bruno Sinopoli; Bruce H. Krogh

2008-12-01T23:59:59.000Z

69

Transformer Load Tap Changer Management: Diagnostics, Contact Coking, and On-line Oil Filtration  

Science Conference Proceedings (OSTI)

Load tap changers (LTCs) are the single biggest contributor to transformer problems. Their failure modes may be mechanical, electrical, or related to the quality of oil and contacts. Utilities are seeking new strategies regarding LTC maintenance to minimize these problems and, at the same time, reduce maintenance costs. EPRI has initiated several projects with a goal towards a "Maintenance-Free LTC." This report summarizes work to date under EPRI/BC Hydro sponsorship to address some of these concerns.

2001-12-12T23:59:59.000Z

70

Impact of Industrial Electric Rate Structure on Load Management - A Utility Viewpoint  

E-Print Network (OSTI)

A few years ago our response to an inquiry regarding availability of electric service for a large industrial load was something like: 'Let us put this into our production model to determine whether we will have adequate generating capacity to commit to your needs plus load increases under contract and anticipated residential and commercial load growth. If our studies show that we will have generating capacity available, then we should allow a minimum of two years for design and construction. Of course, you will need to plan to build and maintain your substation.' Today our response would be more like 'How soon can you be ready? Can we build and/or maintain your substation for you? Perhaps we can locate a transformer for you to use until permanent facilities are in place?' What has happened to utilities such as GSU to change our perspective so quickly? The turn around began around New Years of 82 with the realization by industry that the recession which had been developing for some 6 months in retail and construction areas was now affecting basic industry. Later we learned that this recession was the most severe and long lasting in this country since the great depression of the 1930's and that fundamental changes would be required by basic industry if it were to survive. Resulting plant reductions and closings severely impacted utilities heavily dependent on industrial business.

Richardson, J. A.

1984-01-01T23:59:59.000Z

71

Review of current Southern California edison load management programs and proposal for a new market-driven, mass-market, demand-response program  

Science Conference Proceedings (OSTI)

Utility load management programs, including direct load control and interruptible load programs, constitute a large installed base of controllable loads that are employed by utilities as system reliability resources. In response to energy supply shortfalls expected during the summer of 2001, the California Public Utilities Commission in spring 2001 authorized new utility load management programs as well as revisions to existing programs. This report provides an independent review of the designs of these new programs for a large utility (Southern California Edison) and suggests possible improvements to enhance the price responsiveness of the customer actions influenced by these programs. The report also proposes a new program to elicit a mass-market demand response to utility price signals.

Weller, G.H.

2002-01-01T23:59:59.000Z

72

Implementation of relaxed ACID properties for distributed load management in the electrical power industry  

Science Conference Proceedings (OSTI)

The consistency of data in central databases is normally implemented by using the ACID (Atomicity, Consistency, Isolation and Durability) properties of a DBMS (Data Base Management System). Distributed databases with high performance and availability ... Keywords: ACID properties, automatic process control, distributed systems, electrical power industry, relaxed atomicity property, smart grid conceptual model

Lars Frank; Rasmus Ulslev Pedersen

2013-01-01T23:59:59.000Z

73

Radiation receiver  

DOE Patents (OSTI)

The apparatus for collecting radiant energy and converting same to alternate energy form includes a housing having an interior space and a radiation transparent window allowing, for example, solar radiation to be received in the interior space of the housing. Means are provided for passing a stream of fluid past said window and for injecting radiation absorbent particles in said fluid stream. The particles absorb the radiation and because of their very large surface area, quickly release the heat to the surrounding fluid stream. The fluid stream particle mixture is heated until the particles vaporize. The fluid stream is then allowed to expand in, for example, a gas turbine to produce mechanical energy. In an aspect of the present invention properly sized particles need not be vaporized prior to the entrance of the fluid stream into the turbine, as the particles will not damage the turbine blades. In yet another aspect of the invention, conventional fuel injectors are provided to inject fuel into the fluid stream to maintain the proper temperature and pressure of the fluid stream should the source of radiant energy be interrupted. In yet another aspect of the invention, an apparatus is provided which includes means for providing a hot fluid stream having hot particles disbursed therein which can radiate energy, means for providing a cooler fluid stream having cooler particles disbursed therein, which particles can absorb radiant energy and means for passing the hot fluid stream adjacent the cooler fluid stream to warm the cooler fluid and cooler particles by the radiation from the hot fluid and hot particles. 5 figs.

Hunt, A.J.

1983-09-13T23:59:59.000Z

74

Radiation receiver  

SciTech Connect

The apparatus for collecting radiant energy and converting same to alternate energy form includes a housing having an interior space and a radiation transparent window allowing, for example, solar radiation to be received in the interior space of the housing. Means are provided for passing a stream of fluid past said window and for injecting radiation absorbent particles in said fluid stream. The particles absorb the radiation and because of their very large surface area, quickly release the heat to the surrounding fluid stream. The fluid stream particle mixture is heated until the particles vaporize. The fluid stream is then allowed to expand in, for example, a gas turbine to produce mechanical energy. In an aspect of the present invention properly sized particles need not be vaporized prior to the entrance of the fluid stream into the turbine, as the particles will not damage the turbine blades. In yet another aspect of the invention, conventional fuel injectors are provided to inject fuel into the fluid stream to maintain the proper temperature and pressure of the fluid stream should the source of radiant energy be interrupted. In yet another aspect of the invention, an apparatus is provided which includes means for providing a hot fluid stream having hot particles disbursed therein which can radiate energy, means for providing a cooler fluid stream having cooler particles disbursed therein, which particles can absorb radiant energy and means for passing the hot fluid stream adjacent the cooler fluid stream to warm the cooler fluid and cooler particles by the radiation from the hot fluid and hot particles.

Hunt, Arlon J. (Oakland, CA)

1983-01-01T23:59:59.000Z

75

Demonstration of Smart Building Controls to Manage Building Peak Loads: Innovative Non-Wires Technologies  

SciTech Connect

As a part of the non-wires solutions effort, BPA in partnership with Pacific Northwest National Laboratory (PNNL) is exploring the use of two distributed energy resources (DER) technologies in the City of Richland. In addition to demonstrating the usefulness of the two DER technologies in providing peak demand relief, evaluation of remote direct load control (DLC) is also one of the primary objectives of this demonstration. The concept of DLC, which is used to change the energy use profile during peak hours of the day, is not new. Many utilities have had success in reducing demand at peak times to avoid building new generation. It is not the need for increased generation that is driving the use of direct load control in the Northwest, but the desire to avoid building additional transmission capacity. The peak times at issue total between 50 and 100 hours a year. A transmission solution to the problem would cost tens of millions of dollars . And since a ?non wires? solution is just as effective and yet costs much less, the capital dollars for construction can be used elsewhere on the grid where building new transmission is the only alternative. If by using DLC, the electricity use can be curtailed, shifted to lower use time periods or supplemented through local generation, the existing system can be made more reliable and cost effective.

Katipamula, Srinivas; Hatley, Darrel D.

2004-12-22T23:59:59.000Z

76

Demand-Side and Supply-Side Load Management: Optimizing with Thermal Energy Storage (TES) for the Restructuring Energy Marketplace  

E-Print Network (OSTI)

The current and future restructuring energy marketplace represents a number of challenges and opportunities to maximize value through the management of peak power. This is true both on the demand-side regarding peak power use and on the supply-side regarding power generation. Thermal Energy Storage (TES) can provide the flexibility essential to the economical management of power. In large industrial applications, the added value of TES has been demonstrated, not only in managing operating costs, but also in delivering a net saving in capital cost versus conventional, non-storage approaches. This capital cost saving is often realized in situations where investments in chiller plant capacity, or in on-site power generating capacity, are required. On the demand-side, TES has long been used to shift air-conditioning loads and process cooling loads from on-peak to off-peak periods. In today's and tomorrow's restructuring energy markets, price spikes are increasingly likely during periods of peak power demand. TES is performing an important role, especially when coupled with a proper understanding of modern TES technology options. The inherent advantages and limitations of the available TES technology options are briefly reviewed and discussed. Examples of existing large TES installations are presented, identifying the TES technology types they utilize. The applications include industrial facilities, as well as universities, hospitals, government, and District Cooling utility systems. The power management impact and the economic benefits of TES are illustrated through a review of several TES case studies. Combustion Turbines (CTs) are a common choice for modern on-site and utility power generation facilities. Inlet air cooling of CTs enhances their hot weather performance and has been successfully accomplished for many years, using a variety of technologies. In many instances, TES can and does provide a uniquely advantageous method of optimizing the economics of CT Inlet Cooling (CTIC) systems. TES systems can achieve low inlet air temperatures, with resulting high levels of power augmentation. The TES approach also minimizes the installed capacity (and capital cost) of cooling systems, as well as limiting the parasitic loads occurring during periods of peak power demand and peak power value. Chilled water, ice, and low temperature fluid TES systems are all applicable to CTIC. The inherent pros and cons of each TES type are discussed. Sensitivity analyses are presented to explore the impact of cooling hours per day on capital cost per kW of power enhancement. Case histories illustrate the beneficial impact of TES-based CTIC on both capital cost and operating cost of CT power plants. TES-based CTIC is advantageous as an economical, peaking power enhancement for either peaking or base-load plants. It is applied to both new and existing CTs. TES is projected to have even greater value in future restructuring energy markets.

Andrepont, J. S.

2002-04-01T23:59:59.000Z

77

Responses to comments received on the draft final report of the Secretary of Energy Advisory Board Task Force on Radioactive Waste Management  

SciTech Connect

The Task Force solicited comments on its Draft Final Report from a variety of sources. Letters were sent to over 400 individuals who had expressed interest in the interest in the Department`s radioactive waste, management programs, a notice was placed in the Federal Register, the morning session of the January 1993 meeting of the full Secretary of Energy Advisory Board was given over to discussion of the draft, and Task Force members and staff presented the effort at several professional meetings. Altogether 32 written comments were received. They are reproduced here, followed in each case by the Task Force`s response to specific suggestions made to improve the draft. (The panel did not respond to comments that simply reflected policy preferences or that praised the group`s effort.) With one exception, those specific suggestions are highlighted and given a letter designation from {open_quotes}A{close_quotes} to {open_quotes}Z{close_quotes}. The Task Force`s responses, written in the Fall 1993, are labeled in a like manner. For the one exception, a comments submitted by Judy Treichel, the Task Force`s response is printed on copies of her annotated pages.

Not Available

1994-10-01T23:59:59.000Z

78

A Bio-Inspired Multi-Agent System Framework for Real-Time Load Management in All-Electric Ship Power Systems  

E-Print Network (OSTI)

All-electric ship power systems have limited generation capacity and finite rotating inertia compared with large power systems. Moreover, all-electric ship power systems include large portions of nonlinear loads and dynamic loads relative to the total power capacity, which may significantly reduce the stability margin. Pulse loads and other high-energy weapon loads in the system draw a large amount of power intermittently, which may cause significant frequency and voltage oscillations in the system. Thus, an effective real-time load management technique is needed to dynamically balance the load and generation to operate the system normally. Multi-agent systems, inspired by biological phenomena, aim to cooperatively achieve system objectives that are difficult to reach by a single agent or centralized controller. Since power systems include various electrical components with different dynamical systems, conventional homogeneous multi-agent system cooperative controllers have difficulties solving the real-time load management problem with heterogeneous agents. In this dissertation, a novel heterogeneous multi-agent system cooperative control methodology is presented based on artificial potential functions and reduced-order agent models to cooperatively achieve real-time load management for all-electric ship power systems. The technique integrates high-order system dynamics and various kinds of operational constraints into the multi-agent system, which improves the accuracy of the cooperative controller. The multi-agent system includes a MVAC multiagent system and a DC zone multi-agent, which are coordinated by an AC-DC communication agent. The developed multi-agent system framework and the notional all-electric ship power system model were simulated in PSCAD software. Case studies and performance analysis of the MVAC multi-agent system and the DC zone multi-agent system were performed. The simulation results indicated that propulsion loads and pulse loads can be successfully coordinated to reduce the impact of pulse loads on the power quality of all-electric ship power systems. Further, the switch status or power set-point of loads in DC zones can be optimally determined to dynamically balance the generation and load while satisfying the operational constraints of the system and considering load priorities. The method has great potential to be extended to other isolated power systems, such as microgrids.

Feng, Xianyong

2012-05-01T23:59:59.000Z

79

Testing a new direct load control power line communication system  

SciTech Connect

South Carolina Electric and Gas is currently performing direct load control communications over power lines without using a power line carrier. This is the result of testing a load management system that combines the existing substation solid-state recording with voltage regulation capability. Using the solid-state recorder's extended control functions, the existing substation tap changer, a new patent-pending power line communications technique, and a patented voltage-step load control receiver, the system extends normal two-way communication between the utility operations and the substation with a one-way power line link to virtually any load. By varying the voltage level slightly, the system digitizes up to 32 different load control messages. The new voltage-step communication technique uses the substation's load tap changer to communicate one-way with the receivers over existing power lines. South Carolina Electric and Gas and the manufacturers have been performing a two-phase test of the load control system. Phase one testing showed that the percentage of successful load control message reception was 98%. Phase two testing is still in progress. Results to date show no deterioration of reception or equipment. Conclusions thus far are that the load management system is compatible with all installed utility equipment, and offers reliable direct load control.

Weers, D.D.; Shamsedin, M.A.

1987-07-01T23:59:59.000Z

80

Lessons Learned: A review of utility experience with conservation and load management programs for commercial and industrial customers  

SciTech Connect

This report examines utility experience with conservation and load management (C LM) programs of commercial and industrial (C I) customers in order to summarize the lessons learned from program experiences to date and what these teach us about how to operate successful programs in the future. This analysis was motivated by a desire to learn about programs which achieve high participation rates and high electricity savings while remaining cost effective. Also, we wanted to review the very latest experiences with innovative program approaches -- approaches that might prove useful to utilities as they scale up their C LM activities. Specific objectives of this phase of the study are threefold: (1) To disseminate information on utility C LM experience to a nationwide audience. (2) To review current New York State utility programs and make suggestions on how these programs can be improved. (3) To collect data for the final phase of the American Council for an Energy-Efficient Economy/New York State Energy Research and Development Authority project, which will examine the savings that are achievable if C LM programs are pushed to the limit'' of current knowledge on how to structure and run cost-effective C LM programs. 19 tabs.

Nadel, S.

1990-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "load management receiver" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Predictive modeling for collections of accounts receivable  

Science Conference Proceedings (OSTI)

It is commonly agreed that accounts receivable (AR) can be a source of financial difficulty for firms when they are not efficiently managed and are underperforming. Experience across multiple industries shows that effective management of AR and overall ... Keywords: accounts receivable, invoice to cash, knowledge discovery, order to cash, payment collection, predictive modeling

Sai Zeng; Ioana Boier-Martin; Prem Melville; Conrad Murphy; Christian A. Lang

2007-08-01T23:59:59.000Z

82

Distribution substation load impacts of residential air conditioner load control  

SciTech Connect

An ongoing experiment to monitor the substation level load impacts of end-use load control is described. An overview of the data acquisition system, experimental procedures and analysis techniques are provided. Results of the 1983 and 1984 experiments demonstrate the value of aggregate load impact monitoring as a means of verifying load research results, calculating the diversity of end-use loads, and predicting the impacts of load management on the transmission and distribution systems.

Heffner, G.C.; Kaufman, D.A.

1985-07-01T23:59:59.000Z

83

Wind Energy Management System Integration Project Incorporating Wind Generation and Load Forecast Uncertainties into Power Grid Operations  

SciTech Connect

The power system balancing process, which includes the scheduling, real time dispatch (load following) and regulation processes, is traditionally based on deterministic models. Since the conventional generation needs time to be committed and dispatched to a desired megawatt level, the scheduling and load following processes use load and wind power production forecasts to achieve future balance between the conventional generation and energy storage on the one side, and system load, intermittent resources (such as wind and solar generation) and scheduled interchange on the other side. Although in real life the forecasting procedures imply some uncertainty around the load and wind forecasts (caused by forecast errors), only their mean values are actually used in the generation dispatch and commitment procedures. Since the actual load and intermittent generation can deviate from their forecasts, it becomes increasingly unclear (especially, with the increasing penetration of renewable resources) whether the system would be actually able to meet the conventional generation requirements within the look-ahead horizon, what the additional balancing efforts would be needed as we get closer to the real time, and what additional costs would be incurred by those needs. In order to improve the system control performance characteristics, maintain system reliability, and minimize expenses related to the system balancing functions, it becomes necessary to incorporate the predicted uncertainty ranges into the scheduling, load following, and, in some extent, into the regulation processes. It is also important to address the uncertainty problem comprehensively, by including all sources of uncertainty (load, intermittent generation, generators’ forced outages, etc.) into consideration. All aspects of uncertainty such as the imbalance size (which is the same as capacity needed to mitigate the imbalance) and generation ramping requirement must be taken into account. The latter unique features make this work a significant step forward toward the objective of incorporating of wind, solar, load, and other uncertainties into power system operations. In this report, a new methodology to predict the uncertainty ranges for the required balancing capacity, ramping capability and ramp duration is presented. Uncertainties created by system load forecast errors, wind and solar forecast errors, generation forced outages are taken into account. The uncertainty ranges are evaluated for different confidence levels of having the actual generation requirements within the corresponding limits. The methodology helps to identify system balancing reserve requirement based on a desired system performance levels, identify system “breaking points”, where the generation system becomes unable to follow the generation requirement curve with the user-specified probability level, and determine the time remaining to these potential events. The approach includes three stages: statistical and actual data acquisition, statistical analysis of retrospective information, and prediction of future grid balancing requirements for specified time horizons and confidence intervals. Assessment of the capacity and ramping requirements is performed using a specially developed probabilistic algorithm based on a histogram analysis incorporating all sources of uncertainty and parameters of a continuous (wind forecast and load forecast errors) and discrete (forced generator outages and failures to start up) nature. Preliminary simulations using California Independent System Operator (California ISO) real life data have shown the effectiveness of the proposed approach. A tool developed based on the new methodology described in this report will be integrated with the California ISO systems. Contractual work is currently in place to integrate the tool with the AREVA EMS system.

Makarov, Yuri V.; Huang, Zhenyu; Etingov, Pavel V.; Ma, Jian; Guttromson, Ross T.; Subbarao, Krishnappa; Chakrabarti, Bhujanga B.

2010-09-01T23:59:59.000Z

84

Decentralized customerlevel under frequency load shedding in...  

Open Energy Info (EERE)

enables the management of large groups of distributed loads under a single innovative control schemes to use the flexibility of electrical loads for power system purposes....

85

Solar heat receiver  

DOE Patents (OSTI)

A receiver for converting solar energy to heat a gas to temperatures from 700.degree.-900.degree. C. The receiver is formed to minimize impingement of radiation on the walls and to provide maximum heating at and near the entry of the gas exit. Also, the receiver is formed to provide controlled movement of the gas to be heated to minimize wall temperatures. The receiver is designed for use with gas containing fine heat absorbing particles, such as carbon particles.

Hunt, Arlon J. (Oakland, CA); Hansen, Leif J. (Berkeley, CA); Evans, David B. (Orinda, CA)

1985-01-01T23:59:59.000Z

86

Solar heat receiver  

DOE Patents (OSTI)

A receiver is described for converting solar energy to heat a gas to temperatures from 700 to 900/sup 0/C. The receiver is formed to minimize impingement of radiation on the walls and to provide maximum heating at and near the entry of the gas exit. Also, the receiver is formed to provide controlled movement of the gas to be heated to minimize wall temperatures. The receiver is designed for use with gas containing fine heat absorbing particles, such as carbon particles.

Hunt, A.J.; Hansen, L.J.; Evans, D.B.

1982-09-29T23:59:59.000Z

87

Ceramic solar receivers  

DOE Green Energy (OSTI)

The application of ceramic materials to high temperature solar receivers for advanced Brayton and advanced Stirling thermal electric systems is discussed. Conceptual designs for ceramic cavity receivers employing impingement jet-cooled, dome-shaped silicon carbide heat exchanger modules are offered. Optical, mechanical, heat transfer and structural analyses of this novel receiver approach are presented.

Jarvinen, P. O.

1979-01-01T23:59:59.000Z

88

Load cell  

DOE Patents (OSTI)

A load cell combines the outputs of a plurality of strain gauges to measure components of an applied load. Combination of strain gauge outputs allows measurement of any of six load components without requiring complex machining or mechanical linkages to isolate load components. An example six axis load cell produces six independent analog outputs, each directly proportional to one of the six general load components. 16 figs.

Spletzer, B.L.

1998-12-15T23:59:59.000Z

89

Load cell  

DOE Patents (OSTI)

A load cell combines the outputs of a plurality of strain gauges to measure components of an applied load. Combination of strain gauge outputs allows measurement of any of six load components without requiring complex machining or mechanical linkages to isolate load components. An example six axis load cell produces six independent analog outputs which can be combined to determine any one of the six general load components.

Spletzer, Barry L. (Albuquerque, NM)

2001-01-01T23:59:59.000Z

90

Load cell  

DOE Patents (OSTI)

A load cell combines the outputs of a plurality of strain gauges to measure components of an applied load. Combination of strain gauge outputs allows measurement of any of six load components without requiring complex machining or mechanical linkages to isolate load components. An example six axis load cell produces six independent analog outputs, each directly proportional to one of the six general load components.

Spletzer, Barry L. (Albuquerque, NM)

1998-01-01T23:59:59.000Z

91

LM Receives Sustainability Award | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Receives Sustainability Award Receives Sustainability Award LM Receives Sustainability Award January 8, 2013 - 1:17pm Addthis Award ceremony (left to right): Melvin G. Williams, Jr., Associate Deputy Secretary, U.S. Department of Energy (DOE); Mary Sizemore, Environmental Management System (EMS) Coordinator, Office of Legacy Management (LM) contractor; Tracy Ribeiro, EMS Coordinator, LM; Tom Pauling, Director of Site Operations, LM; Dave Geiser, Director, LM; and Jennifer MacDonald, Director, Sustainability Performance Office, DOE. Award ceremony (left to right): Melvin G. Williams, Jr., Associate Deputy Secretary, U.S. Department of Energy (DOE); Mary Sizemore, Environmental Management System (EMS) Coordinator, Office of Legacy Management (LM) contractor; Tracy Ribeiro, EMS Coordinator, LM; Tom Pauling, Director of

92

NETL Researchers Receive  

NLE Websites -- All DOE Office Websites (Extended Search)

1, Issue 20 1, Issue 20 the lab NETL Researchers Receive 2010 R&D 100 Awards page 2 NETL Employees Receive USGS Director's Award for Exemplary Service to the Nation page 3 Exciting New Raman Gas Sensor System page 5 NETLOG is a quarterly newsletter, which highlights recent achievements and ongoing research at NETL. Any comments or suggestions, please contact Paula Turner at paula.turner@netl.doe.gov or call 541-967-5966. R&D 100 award recipients Paul Jablonski and David Alman at the black tie ceremony on November 11 in Orlando. CONTENTS NETL Researchers Receive 2010 R&D 100 Awards _______ 2 NETL Employees Receive USGS Director's Award for Exemplary Service to the Nation _____________________ 3 NETL Develops Smart Drilling Fluids ____________________

93

Shipping and Receiving  

NLE Websites -- All DOE Office Websites (Extended Search)

Shipping and Receiving Print Shipping and Receiving Print On this page: Transport Policy Shipping to the ALS Shipping from the ALS Shipping Hazardous Materials Contacts: ALS Shipping & Receiving (small packages) LBNL Shipping & Receiving (large packages requiring forklift truck) Building 7 Hours: M-F, 7:30 am-4:30 pm Telephone: 510 486 4494 Building 69 Hours: M-F, 7:00 am-3:30 pm Telephone: 510 486 4935 Fax: 510 486 5668 Transport Policy - Getting Your Samples and Equipment to and from the ALS All Lab personnel, including ALS staff and users, must follow the procedures detailed below for packing, labeling, and sending shipments to or from the ALS. These shipping procedures are required for: all materials and equipment brought to the ALS; items that are being returned for repairs or refunds to

94

Solar energy receiver  

DOE Patents (OSTI)

An improved long-life design for solar energy receivers provides for greatly reduced thermally induced stress and permits the utilization of less expensive heat exchanger materials while maintaining receiver efficiencies in excess of 85% without undue expenditure of energy to circulate the working fluid. In one embodiment, the flow index for the receiver is first set as close as practical to a value such that the Graetz number yields the optimal heat transfer coefficient per unit of pumping energy, in this case, 6. The convective index for the receiver is then set as closely as practical to two times the flow index so as to obtain optimal efficiency per unit mass of material.

Schwartz, Jacob (Arlington, MA)

1978-01-01T23:59:59.000Z

95

Lab receives OPCW recertification  

NLE Websites -- All DOE Office Websites (Extended Search)

Vu, and Audrey Williams. In 2011, LLNL, as well as the laboratories from Spain and Poland, received "C" grades that weren't based on technical issues, but were mainly based on...

96

Pantexan receives Crime Stoppers volunteer award | National Nuclear...  

NLE Websites -- All DOE Office Websites (Extended Search)

Pantexan receives Crime Stoppers volunteer award | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy...

97

NETL: News Release - Drilling Operators Receive Boost from New...  

NLE Websites -- All DOE Office Websites (Extended Search)

Drilling Operators Receive Boost from New Database to Weigh Options Regarding Waste Management Interactive Website Provides Easy Access to Technological, Environmental, and...

98

Newest LANL Facility Receives LEED Gold Certification | National...  

NLE Websites -- All DOE Office Websites (Extended Search)

Newest LANL Facility Receives LEED Gold Certification | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear...

99

Lempke receives Sandia Emergency Operations Center tour | National...  

NLE Websites -- All DOE Office Websites (Extended Search)

receives Sandia Emergency Operations Center tour | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy...

100

Central solar energy receiver  

DOE Patents (OSTI)

An improved tower-mounted central solar energy receiver for heating air drawn through the receiver by an induced draft fan. A number of vertically oriented, energy absorbing, fin-shaped slats are radially arranged in a number of concentric cylindrical arrays on top of the tower coaxially surrounding a pipe having air holes through which the fan draws air which is heated by the slats which receive the solar radiation from a heliostat field. A number of vertically oriented and wedge-shaped columns are radially arranged in a number of concentric cylindrical clusters surrounding the slat arrays. The columns have two mirror-reflecting sides to reflect radiation into the slat arrays and one energy absorbing side to reduce reradiation and reflection from the slat arrays.

Drost, M. Kevin (Richland, WA)

1983-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "load management receiver" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Receiver System: Lessons Learned From Solar Two  

DOE Green Energy (OSTI)

The Boeing Company fabricated the Solar Two receiver as a subcontractor for the Solar Two project. The receiver absorbed sunlight reflected from the heliostat field. A molten-nitrate-salt heat transfer fluid was pumped from a storage tank at grade level, heated from 290 to 565 C by the receiver mounted on top of a tower, then flowed back down into another storage tank. To make electricity, the hot salt was pumped through a steam generator to produce steam that powered a conventional Rankine steam turbine/generator. This evaluation identifies the most significant Solar Two receiver system lessons learned from the Mechanical Design, Instrumentation and Control, Panel Fabrication, Site Construction, Receiver System Operation, and Management from the perspective of the receiver designer/manufacturer. The lessons learned on the receiver system described here consist of two parts: the Problem and one or more identified Solutions. The appendix summarizes an inspection of the advanced receiver panel developed by Boeing that was installed and operated in the Solar Two receiver.

LITWIN, ROBERT Z.; PACHECO, JAMES E.

2002-03-01T23:59:59.000Z

102

Multichannel homodyne receiver  

DOE Patents (OSTI)

A homodyne radar transmitter/receiver device which produces a single combined output which contains modulated backscatter information for all phase conditions of both modulated and unmodulated backscatter signals is described. The device utilizes taps along coaxial transmission lines, strip transmission line, and waveguides which are spaced by 1/8 wavelength or 1/6 wavelength, etc. This greatly reduces costs by eliminating separate transmission and reception antennas and an expensive arrangement of power splitters and mixers utilized in the prior art.

Landt, J.A.

1981-01-19T23:59:59.000Z

103

Multichannel homodyne receiver  

DOE Patents (OSTI)

A homodyne radar transmitter/receiver device which produces a single combined output which contains modulated backscatter information for all phase conditions of both modulated and unmodulated backscatter signals. The device utilizes taps along coaxial transmission lines, strip transmission line, and waveguides which are spaced by 1/8 wavelength or 1/6 wavelength, etc. This greatly reduces costs by eliminating separate transmission and reception antennas and an expensive arrangement of power splitters and mixers utilized in the prior art.

Landt, Jeremy A. (Los Alamos, NM)

1982-01-01T23:59:59.000Z

104

A bio-inspired multi-agent system framework for real-time load management in all-electric ship power systems  

Science Conference Proceedings (OSTI)

All-electric ship power systems have limited generation capacity and finite rotating inertia compared with large power systems. Moreover, all-electric ship power systems include large portions of nonlinear loads and dynamic loads relative to the total ...

Xianyong Feng / Karen L. Butler-Purry

2012-01-01T23:59:59.000Z

105

Neural-wavelet Methodology for Load Forecasting  

Science Conference Proceedings (OSTI)

Intelligent demand-side management represents a future trend of power system regulation. A key issue in intelligent demand-side management is accurate prediction of load within a local area grid (LAG), which is defined as a set of customers with an appropriate ... Keywords: load forecasting, load identification, neural-wavelet

Rong Gao; Lefteri H. Tsoukalas

2001-05-01T23:59:59.000Z

106

Tax barriers to solar central receiver generation technology  

DOE Green Energy (OSTI)

Tax loads and required revenues are estimated for current and future solar central receiver and gas-fired plants competing in the same market. An economic measure of tax equity is used to evaluate the equity of the tax loads under past and present tax codes. The same measure is used to devise a tax strategy which produces the following two types of equitable taxation: (1) the two plants carry nearly equal tax loads, and (2) local, state and federal governments receive the same distribution of revenues from the solar plant as from the gas-fired plant `Me results show that central receivers (and likely other capital-intensive technologies) carry higher tax loads compared to competing gasfired generation, that tax loads are highly correlated with competitiveness, and that equitable taxation is feasible within the boundaries of the study.

Jenkins, A.F. [California Energy Commission, Sacramento, CA (United States); Reilly, H.E. [Sandia National Labs., Albuquerque, NM (United States)

1994-12-31T23:59:59.000Z

107

Property types eligible to receive a 1-100 ENERGY STAR score...  

NLE Websites -- All DOE Office Websites (Extended Search)

Property types eligible to receive a 1-100 ENERGY STAR score Secondary menu About us Press room Contact Us Portfolio Manager Login Facility owners and managers Existing...

108

Dynamic load balancing of applications  

DOE Patents (OSTI)

An application-level method for dynamically maintaining global load balance on a parallel computer, particularly on massively parallel MIMD computers. Global load balancing is achieved by overlapping neighborhoods of processors, where each neighborhood performs local load balancing. The method supports a large class of finite element and finite difference based applications and provides an automatic element management system to which applications are easily integrated.

Wheat, Stephen R. (Albuquerque, NM)

1997-01-01T23:59:59.000Z

109

Dynamic load balancing of applications  

DOE Patents (OSTI)

An application-level method for dynamically maintaining global load balance on a parallel computer, particularly on massively parallel MIMD computers is disclosed. Global load balancing is achieved by overlapping neighborhoods of processors, where each neighborhood performs local load balancing. The method supports a large class of finite element and finite difference based applications and provides an automatic element management system to which applications are easily integrated. 13 figs.

Wheat, S.R.

1997-05-13T23:59:59.000Z

110

Load Control  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Visualization and Controls Peer Review Visualization and Controls Peer Review Load Control for System Reliability and Measurement-Based Stability Assessment Dan Trudnowski, PhD, PE Montana Tech Butte, MT 59701 dtrudnowski@mtech.edu 406-496-4681 October 2006 2 Presentation Outline * Introduction - Goals, Enabling technologies, Overview * Load Control - Activities, Status * Stability Assessment - Activities, Status * Wrap up - Related activities, Staff 3 Goals * Research and develop technologies to improve T&D reliability * Technologies - Real-time load control methodologies - Measurement-based stability-assessment 4 Enabling Technologies * Load control enabled by GridWise technology (e.g. PNNL's GridFriendly appliance) * Real-time stability assessment enabled by Phasor Measurement (PMU) technology 5 Project Overview * Time line: April 18, 2006 thru April 17, 2008

111

Load-shape development aids planning  

SciTech Connect

The concept that provides capable, load-shape development, is being adopted by several utilities and power pools. Public Service Electric and Gas Company has developed a computer simulation model that can predict a utility's load shape for up to a 30-year period. The objective of the PSE and G model, known as EICS (Electric Load-Curve Synthesis) is to provide a demand profile, to examine the impact of load mangement and other activities upon a system's load shape, and to apply appropriate forecast non-load-management and load-management impacts before finally examining the resulting revised load-shape. Other models dealing with load-shape are discussed. Specifically, the Systems Control Inc. model for EPRI (SCI/EPRI), useful in performing accurate simulations of various load-control strategies involving customer appliance control is mentioned.

Gellings, C.W.

1979-12-15T23:59:59.000Z

112

NNSA's Global Threat Reduction Initiative Receives 2010 Distinguished  

NLE Websites -- All DOE Office Websites (Extended Search)

Receives 2010 Distinguished Receives 2010 Distinguished Project Award from PMI | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > Media Room > Press Releases > NNSA's Global Threat Reduction Initiative Receives 2010 ... Press Release NNSA's Global Threat Reduction Initiative Receives 2010 Distinguished

113

LOADING DEVICE  

DOE Patents (OSTI)

A device is presented for loading or charging bodies of fissionable material into a reactor. This device consists of a car, mounted on tracks, into which the fissionable materials may be placed at a remote area, transported to the reactor, and inserted without danger to the operating personnel. The car has mounted on it a heavily shielded magazine for holding a number of the radioactive bodies. The magazine is of a U-shaped configuration and is inclined to the horizontal plane, with a cap covering the elevated open end, and a remotely operated plunger at the lower, closed end. After the fissionable bodies are loaded in the magazine and transported to the reactor, the plunger inserts the body at the lower end of the magazine into the reactor, then is withdrawn, thereby allowing gravity to roll the remaining bodies into position for successive loading in a similar manner.

Ohlinger, L.A.

1958-10-01T23:59:59.000Z

114

WIPP Receives Top Safety Award  

NLE Websites -- All DOE Office Websites (Extended Search)

WIPP Receives Top Safety Award CARLSBAD, N.M., November 10, 2011 - The U.S. Department of Energy's (DOE) Waste Isolation Pilot Plant (WIPP) received top accolades from New...

115

High-temperature ceramic receivers  

DOE Green Energy (OSTI)

An advanced ceramic dome cavity receiver is discussed which heats pressurized gas to temperatures above 1800/sup 0/F (1000/sup 0/C) for use in solar Brayton power systems of the dispersed receiver/dish or central receiver type. Optical, heat transfer, structural, and ceramic material design aspects of the receiver are reported and the development and experimental demonstration of a high-temperature seal between the pressurized gas and the high-temperature silicon carbide dome material is described.

Jarvinen, P. O.

1980-01-01T23:59:59.000Z

116

Structural analysis of a reflux pool-boiler solar receiver  

DOE Green Energy (OSTI)

Coupled thermal-structural finite element calculations of a reflux pool-boiler solar receiver were performed to characterize the operating stresses and to address issues affecting the service life of the receiver. Analyses performed using shell elements provided information for receiver material selection and design optimization. Calculations based on linear elastic fracture mechanics principles were performed using continuum elements to assess the vulnerability of a seam-weld to fatigue crack growth. All calculations were performed using ABAQUS, a general purpose finite element code, and elements specifically formulated for coupled thermal-structural analysis. Two materials were evaluated: 316L SS and Haynes 230 alloys. The receiver response was simulated for a combination of structural and thermal loads that represent the startup and operating conditions of the receiver. For both materials, maximum stresses in the receiver developed shortly after startup due to uneven temperature distribution across the receiver surface. The largest effective stress was near yield in the 316L SS receiver and below 39 percent of yield in the Haynes 230 receiver. The calculations demonstrated that stress reductions of over 25 percent could be obtained by reducing the aft dome thickness to one closer to the absorber. The fatigue calculations demonstrated that the stress distribution near the seam-weld notch depends primarily on the structural load created by internal pressurization of the receiver rather than the thermal, indicating that the thermal loads can be neglected when assessing the stress intensity near the seam-weld notch. The stress intensity factor, computed using the J-integral method and crack opening-displacement field equations, was significantly below the fatigue threshold for most steels. The calculations indicated that the weld notch was always loaded in compression, a condition which is not conducive to fatigue crack growth. 15 refs., 30 figs., 3 tabs.

Hoffman, E.L.; Stone, C.M.

1991-06-01T23:59:59.000Z

117

LOADED WAVEGUIDES  

DOE Patents (OSTI)

>Loaded waveguides are described for the propagation of electromagnetic waves with reduced phase velocities. A rectangular waveguide is dimensioned so as to cut-off the simple H/sub 01/ mode at the operating frequency. The waveguide is capacitance loaded, so as to reduce the phase velocity of the transmitted wave, by connecting an electrical conductor between directly opposite points in the major median plane on the narrower pair of waveguide walls. This conductor may take a corrugated shape or be an aperature member, the important factor being that the electrical length of the conductor is greater than one-half wavelength at the operating frequency. Prepared for the Second U.N. International ConferThe importance of nuclear standards is duscussed. A brief review of the international callaboration in this field is given. The proposal is made to let the International Organization for Standardization (ISO) coordinate the efforts from other groups. (W.D.M.)

Mullett, L.B.; Loach, B.G.; Adams, G.L.

1958-06-24T23:59:59.000Z

118

Domestic load scheduling using genetic algorithms  

Science Conference Proceedings (OSTI)

An approach using a genetic algorithm to optimize the scheduling of domestic electric loads, according to technical and user-defined constraints and input signals, is presented and illustrative results are shown. The aim is minimizing the end-user's ... Keywords: automated energy management, domestic load scheduling, electric loads, genetic algorithms

Ana Soares; Állvaro Gomes; Carlos Henggeler Antunes; Hugo Cardoso

2013-04-01T23:59:59.000Z

119

Ceramic dome receiver technology developments  

DOE Green Energy (OSTI)

The development and experimental demonstration of a high-temperature seal for the SHARE ceramic dome cavity receiver is reported. The mechanical contact seal which was tested on one-foot-diameter silicon-carbide ceramic-dome hardware at pressure differentials to four atmospheres and dome temperatures to 2200/sup 0/F (1200/sup 0/C) showed negligible leakage at expected receiver operating conditions. Potential solar receiver applications for the technology are illustrated.

Jarvinen, P. O.

1980-01-01T23:59:59.000Z

120

Desjarlais received Lifetime Achievement Award  

NLE Websites -- All DOE Office Websites (Extended Search)

Andr Desjarlais received a Lifetime Achievement Award from the Polyisocyanurate Insulation Manufacturers Association (PIMA) during the group's 25th Anniversary celebration...

Note: This page contains sample records for the topic "load management receiver" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Interruptible load control for Taiwan Power Company  

SciTech Connect

Load management is the planning and implementation of those utility activities designed to influence customer use of electricity in ways that will produce desired changes in the utility's load shape. Interruptible load program is an option of load management which provides incentive rate to customers to interrupt or reduce the power demand during the system peak period or emergency condition. Therefore, how to design a proper incentive rate is the most important issue in implementing this program. This paper describes three alternatives designed for the interruptible load program, one of which was activated by Taiwan Power Company (Taipower) and some preliminary results were obtained. The effect of the interruptible load to the system peak demand reduction and the change of daily load curve for large industrial customers were analyzed. This paper estimates the avoided cost and design more appropriate incentive rate structure for interruptible load program.

Chen, C.S.; Leu, J.T. (Dept. of Electrical Engineering, National Sun Yat-Sen Univ., Kaohsiung (TW))

1990-05-01T23:59:59.000Z

122

Plug Load Behavioral Change Demonstration Project  

SciTech Connect

This report documents the methods and results of a plug load study of the Environmental Protection Agency's Region 8 Headquarters in Denver, Colorado, conducted by the National Renewable Energy Laboratory. The study quantified the effect of mechanical and behavioral change approaches on plug load energy reduction and identified effective ways to reduce plug load energy. Load reduction approaches included automated energy management systems and behavioral change strategies.

Metzger, I.; Kandt, A.; VanGeet, O.

2011-08-01T23:59:59.000Z

123

Load Shape Library Version 1.0  

Science Conference Proceedings (OSTI)

The downloadable report details EPRI's efforts to develop a framework of a load database and web-accessible repository of end-use and whole-premise data for application to energy efficiency assessments. The tool provides access to the best available end-use load data and whole-premise data by sector, region and building type. Improved end-use load research data will benefit load forecasters, system planners, energy efficiency program managers and rate design analysts by facilitating integration ...

2013-02-12T23:59:59.000Z

124

WIPP Receives First Shipment | National Nuclear Security Administration  

NLE Websites -- All DOE Office Websites (Extended Search)

WIPP Receives First Shipment | National Nuclear Security Administration WIPP Receives First Shipment | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > About Us > Our History > NNSA Timeline > WIPP Receives First Shipment WIPP Receives First Shipment March 26, 1999 Carlsbad, NM WIPP Receives First Shipment After more than two decades of political, legal, and bureaucratic delays,

125

Load apparatus and method for bolt-loaded compact tension test specimen  

DOE Patents (OSTI)

A bolt-loaded compact tension test specimen load apparatus includes: a) a body having first and second opposing longitudinal ends, the first end comprising an externally threaded portion sized to be threadedly received within the test specimen threaded opening; b) a longitudinal loading rod having first and second opposing longitudinal ends, the loading rod being slidably received in a longitudinal direction within the body internally through the externally threaded portion and slidably extending longitudinally outward of the body first longitudinal end; c) a force sensitive transducer slidably received within the body and positioned to engage relative to the loading rod second longitudinal end; and d) a loading bolt threadedly received relative to the body, the loading bolt having a bearing end surface and being positioned to bear against the transducer to forcibly sandwich the transducer between the loading bolt and loading rod. Also disclosed is a method of in situ determining applied force during crack propagation in a bolt-loaded compact tension test specimen.

Buescher, Jr., Brent J. (Idaho Falls, ID); Lloyd, W. Randolph (Idaho Falls, ID); Ward, Michael B. (Idaho Falls, ID); Epstein, Jonathan S. (Idaho Falls, ID)

1997-01-01T23:59:59.000Z

126

Carlsbad Field Office Receives New Mexico's Silver Award for  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Carlsbad Field Office Receives New Mexico's Silver Award for Carlsbad Field Office Receives New Mexico's Silver Award for Environmental Excellence Carlsbad Field Office Receives New Mexico's Silver Award for Environmental Excellence August 1, 2012 - 12:00pm Addthis DOE Carlsbad Field Office Deputy Manager Ed Ziemianski presents a Waste Isolation Pilot Plant (WIPP) team with the Green Zia Program Silver Level Leader award from the New Mexico Environment Department earlier this month in recognition of environmental initiatives. Shown right of Ziemianski is Farok Sharif, Washington TRU Solutions LLC, the WIPP management and operating contractor, President and General Manager. DOE Carlsbad Field Office Deputy Manager Ed Ziemianski presents a Waste Isolation Pilot Plant (WIPP) team with the Green Zia Program Silver Level

127

WIPP Receives Top Safety Award | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

WIPP Receives Top Safety Award WIPP Receives Top Safety Award WIPP Receives Top Safety Award November 9, 2011 - 12:00pm Addthis Media Contact Deb Gill www.wipp.energy.gov 575-234-7270 CARLSBAD, N.M. - The U.S. Department of Energy's (DOE) Waste Isolation Pilot Plant (WIPP) received top accolades from New Mexico's leading mining organizations. The New Mexico Bureau of Mine Safety (BMS) recently recognized URS Washington TRU Solutions (WTS), LLC, the WIPP management and operating contractor, for receiving the New Mexico Mining Association (NMMA) and New Mexico BMS Safe Operator of the Year Award. "I'm pleased to congratulate Washington TRU Solutions and the WIPP workforce for receiving the state's top mine safety award for 23 of the past 25 years," said Ed Ziemianski, Carlsbad Field Office Interim

128

Optimal management of batteries in electric systems  

DOE Patents (OSTI)

An electric system including at least a pair of battery strings and an AC source minimizes the use and maximizes the efficiency of the AC source by using the AC source only to charge all battery strings at the same time. Then one or more battery strings is used to power the load while management, such as application of a finish charge, is provided to one battery string. After another charge cycle, the roles of the battery strings are reversed so that each battery string receives regular management.

Atcitty, Stanley (Albuquerque, NM); Butler, Paul C. (Albuquerque, NM); Corey, Garth P. (Albuquerque, NM); Symons, Philip C. (Morgan Hill, CA)

2002-01-01T23:59:59.000Z

129

High payload six-axis load sensor  

DOE Patents (OSTI)

A repairable high-payload six-axis load sensor includes a table, a base, and at least three shear-pin load transducers removably mounted between the table and the base. Removable mounting permits easy replacement of damaged shear pins. Preferably, the shear-pin load transducers are responsive to shear forces imparted along the two axes perpendicular to an axis of minimum sensitivity characteristic of the transducer. Responsive to an applied shear force, each shear-pin load transducer can produce an electrical signal proportional to the reaction force. The load sensor can further include a structure for receiving the proportional electrical signals and computing the applied load corresponding to the proportional electrical signals. The computed load can be expressed in terms of a three-dimensional XYZ Cartesian coordinate system.

Jansen, John F. (Knoxville, TN); Lind, Randall F. (Knoxville, TN)

2003-01-01T23:59:59.000Z

130

Management  

E-Print Network (OSTI)

Research has indicated that, depending upon driver and passenger characteristics, passengers can have either a positive or negative influence upon driver behaviour. In conclusion to a recent study investigating the roles that passengers can play to influence, positively and negatively, driver behaviour, Regan and Mitsopoulos (2001) recommended, among other things, that the principles of Crew Resource Management (CRM) training may increase passengers ’ ability to positively influence driver behaviour and also drivers ’ ability to accept constructive feedback. The present study investigated the potential application of CRM training within young driver training in the Australian Capital Territory (ACT). This involved a literature review, an analysis of the differences between the driving and aviation domains, an analysis of the team-based activities and the knowledge, skills and attitudes required during driving to perform those activities, consultation with CRM experts from the aviation and medicine domains and the conduct of six focus groups involving young learner drivers, provisional licence drivers and course teachers. The findings indicate that CRM training as part of young driver training in the ACT is a viable concept to pursue. The application of CRM training within young driver training has potential to significantly enhance the positive and reduce the negative effects of passengers on young driver behaviour, and thus the safety of young drivers and passengers alike. The outcomes of this study formed the basis for a set of recommendations for the development of a young driver CRM training program in the ACT.

Young Drivers; Eve Mitsopoulos; Michael Regan; Janet Anderson; Paul Salmon; Jessica Edquist; Ii Report Documentation Page

2005-01-01T23:59:59.000Z

131

Energy manager design for microgrids  

E-Print Network (OSTI)

refrigeration, space heating, water heating, and loads that can only be met by combustible Energy Manager Design

Firestone, Ryan; Marnay, Chris

2005-01-01T23:59:59.000Z

132

Drell receives National Medal of Science | National Nuclear Security  

National Nuclear Security Administration (NNSA)

Drell receives National Medal of Science | National Nuclear Security Drell receives National Medal of Science | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > Drell receives National Medal of Science Drell receives National Medal of Science Posted By Office of Public Affairs NNSA Blog Sidney Drell, physicist, arms control expert and adviser, is one

133

NNSA's Second Line of Defense Program Receives Capability Award |  

NLE Websites -- All DOE Office Websites (Extended Search)

Second Line of Defense Program Receives Capability Award | Second Line of Defense Program Receives Capability Award | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > NNSA's Second Line of Defense Program Receives ... NNSA's Second Line of Defense Program Receives Capability Award Posted By Office of Public Affairs NNSA's Second Line of Defense (SLD) was awarded the 2013 Non-Conventional

134

NNSA labs, sites receive DOE Sustainability Awards | National Nuclear  

National Nuclear Security Administration (NNSA)

labs, sites receive DOE Sustainability Awards | National Nuclear labs, sites receive DOE Sustainability Awards | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > NNSA labs, sites receive DOE Sustainability Awards NNSA labs, sites receive DOE Sustainability Awards Posted By Office of Public Affairs In keeping with NNSA's commitment to improving the way it does business,

135

Newest LANL Facility Receives LEED Gold Certification | National Nuclear  

National Nuclear Security Administration (NNSA)

Newest LANL Facility Receives LEED Gold Certification | National Nuclear Newest LANL Facility Receives LEED Gold Certification | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > Newest LANL Facility Receives LEED Gold Certification Newest LANL Facility Receives LEED Gold Certification Posted By Office of Public Affairs RULOB LANL's newest facility, the Radiological Laboratory Utility Office

136

Sandia Photovoltaic Vehicle receives GreenGov Presidential Award | National  

National Nuclear Security Administration (NNSA)

Photovoltaic Vehicle receives GreenGov Presidential Award | National Photovoltaic Vehicle receives GreenGov Presidential Award | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > Media Room > Press Releases > Sandia Photovoltaic Vehicle receives GreenGov Presidential Award ... Press Release Sandia Photovoltaic Vehicle receives GreenGov Presidential Award

137

Lempke receives Sandia Emergency Operations Center tour | National Nuclear  

National Nuclear Security Administration (NNSA)

receives Sandia Emergency Operations Center tour | National Nuclear receives Sandia Emergency Operations Center tour | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > Lempke receives Sandia Emergency Operations Center tour Lempke receives Sandia Emergency Operations Center tour Posted By Office of Public Affairs NNSA Blog Brian Bielecki, Director & Facility Security Officer for Security &

138

Central solar-energy receiver  

DOE Patents (OSTI)

An improved tower-mounted central solar energy receiver for heating air drawn through the receiver by an induced draft fan is described. A number of vertically oriented, energy absorbing, fin-shaped slats are radially arranged in a number of concentric cylindrical arrays on top of the tower coaxially surrounding a pipe having air holes through which the fan draws air which is heated by the slats which receive the solar radiation from a heliostat field. A number of vertically oriented and wedge-shaped columns are radially arranged in a number of concentric cylindrical clusters surrounding the slat arrays. The columns have two mirror-reflecting sides to reflect radiation into the slat arrays and one energy absorbing side to reduce reradiation and reflection from the slat arrays.

Not Available

1981-10-27T23:59:59.000Z

139

UWB communication receiver feedback loop  

DOE Patents (OSTI)

A novel technique and structure that maximizes the extraction of information from reference pulses for UWB-TR receivers is introduced. The scheme efficiently processes an incoming signal to suppress different types of UWB as well as non-UWB interference prior to signal detection. Such a method and system adds a feedback loop mechanism to enhance the signal-to-noise ratio of reference pulses in a conventional TR receiver. Moreover, sampling the second order statistical function such as, for example, the autocorrelation function (ACF) of the received signal and matching it to the ACF samples of the original pulses for each transmitted bit provides a more robust UWB communications method and system in the presence of channel distortions.

Spiridon, Alex (Palo Alto, CA); Benzel, Dave (Livermore, CA); Dowla, Farid U. (Castro Valley, CA); Nekoogar, Faranak (San Ramon, CA); Rosenbury, Erwin T. (Castro Valley, CA)

2007-12-04T23:59:59.000Z

140

WIPP Security Contractor Receives DOE Voluntary Protection Program Award |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Contractor Receives DOE Voluntary Protection Program Contractor Receives DOE Voluntary Protection Program Award WIPP Security Contractor Receives DOE Voluntary Protection Program Award October 24, 2012 - 12:00pm Addthis Department of Energy Carlsbad Field Site Operations Director Casey Gadbury (right) and Farok Sharif, President and Project Manager for Nuclear Waste Partnership LLC, the management and operating contractor at the Waste Isolation Pilot Plant, present the DOE's Voluntary Protection Program Legacy Star Award to Richard De Los Santos, protective force manager for Security Walls, the security contractor at the Waste Isolation Pilot Plant. The DOE-VPP legacy star award is the highest level of recognition possible in the VPP. Department of Energy Carlsbad Field Site Operations Director Casey Gadbury

Note: This page contains sample records for the topic "load management receiver" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Analytical and demonstration experience with changing load profile. Final report  

SciTech Connect

A bibliography of load management and supply management projects, sponsored by EPRI, was developed. Summaries of project scope and results were made for a selection of these projects already completed. Finally, summaries of six utility load management demonstration projects were made, including project descriptions and presentation of selected results.

Isaksen, L.; Khan, S.; Ma, F.S.

1979-12-01T23:59:59.000Z

142

Exploiting home automation protocols for load monitoring in smart buildings  

Science Conference Proceedings (OSTI)

Monitoring and controlling electrical loads is crucial for demand-side energy management in smart grids. Home automation (HA) protocols, such as X10 and Insteon, have provided programmatic load control for many years, and are being widely deployed in ...

David Irwin; Sean Barker; Aditya Mishra; Prashant Shenoy; Anthony Wu; Jeannie Albrecht

2011-11-01T23:59:59.000Z

143

FPGA side-channel receivers  

Science Conference Proceedings (OSTI)

The popularity of FPGAs is rapidly growing due to the unique advantages that they offer. However, their distinctive features also raise new questions concerning the security and communication capabilities of an FPGA-based hardware platform. In this paper, ... Keywords: ddr2, fpga, i2c, phase shift, side-channel receiver, thermal

Ji Sun; Ray Bittner; Ken Eguro

2011-02-01T23:59:59.000Z

144

RFID receiver apparatus and method  

DOE Patents (OSTI)

An RFID backscatter interrogator for transmitting data to an RFID tag, generating a carrier for the tag, and receiving data from the tag modulated onto the carrier, the interrogator including a single grounded-coplanar wave-guide circuit board and at least one surface mount integrated circuit supported by the circuit board.

Scott, Jeffrey Wayne (Pasco, WA)

2006-12-26T23:59:59.000Z

145

Sandia National Laboratories: Sandia Receives Award for Electronics  

NLE Websites -- All DOE Office Websites (Extended Search)

News News Environmental Management System Pollution Prevention Sustainable Acquisition Electronics Stewardship Recycling Reuse Outreach Awards News About News Sandia Receives Award for Electronics Stewardship September 19, 2011 electronics stewardship award ALBUQUERQUE, N.M. - Sandia National Laboratories has received an award for reducing the environmental impacts of the computers, printers and other office electronics it uses through its fiscal year 2010 electronics stewardship activities. The U.S. Environmental Protection Agency (EPA) and the Office of the Federal Environmental Executive, which jointly manage the Federal Electronics Challenge (FEC), gave Sandia a silver award for its progress in life cycle electronics stewardship (purchasing, operations and end-of-life

146

Assessment of Industrial-Sector Load Shapes  

Science Conference Proceedings (OSTI)

The load shapes of industrial-sector customers are becoming increasingly important for utility forecasting, marketing, and demand-side management planning and evaluation activities. This report analyzes load shapes for various industry segments and investigates the transfer of these load shapes across service territories. This report is available only to funders of Program 101A or 101.001. Funders may download this report at http://my.primen.com/Applications/DE/Community/index.asp .

1993-02-18T23:59:59.000Z

147

Periodic load balancing  

Science Conference Proceedings (OSTI)

Multiprocessor load balancing aims to improve performance by moving jobs from highly loaded processors to more lightly loaded processors. Some schemes allow only migration of new jobs upon arrival, while other schemes allow migration of ... Keywords: heavy traffic diffusion approximations, load balancing, periodic load balancing, reflected Brownian motion, resource sharing, transient behavior

Gísli Hjálmtýsson; Ward Whitt

1998-06-01T23:59:59.000Z

148

Analysis Methodology for Industrial Load Profiles  

E-Print Network (OSTI)

A methodology is provided for evaluating the impact of various demand-side management (DSM) options on industrial customers. The basic approach uses customer metered load profile data as a basis for the customer load shape. DSM technologies are represented as load shapes and are used as a basis for altering the customers existing measured load shape. The impact of load shape changes on the customer is evaluated in terms of a change in the electric bill by using a software analytical tool called LOADEXPERT™. The software calculates the customer's bill for a particular rate structure and a given load shape. The output data from LOADEXPERT™ are used to calculate the rate of return on the DSM technology investment. Other uses of load profile data are provided.

Reddoch, T. W.

1991-06-01T23:59:59.000Z

149

Realizing load reduction functions by aperiodic switching of load groups  

SciTech Connect

This paper investigates the problem of scheduling ON/OFF switching of residential appliances under the control of a Load Management System (LMS). The scheduling process is intended to reduce the controlled appliances` power demand in accordance with a predefined load reduction profile. To solve this problem, a solution approach, based on the methodology of Pulse Width Modulation (PWM), is introduced. This approach provides a flexible mathematical basis for studying different aspects of the scheduling problem. The conventional practices in this area are shown to be special cases of the PWM technique. By applying the PWM-based technique to the scheduling problem, important classes of scheduling errors are identified and analytical expressions describing them are derived. These expressions are shown to provide sufficient information to compensate for the errors. Detailed simulations of load groups` response to switching actions are use to support conclusions of this study.

Navid-Azarbaijani, N. [McGill Univ., Montreal, Quebec (Canada). Dept. of Electrical Engineering; Banakar, M.H. [CAE Electronics Ltd., St. Laurent, Quebec (Canada)

1996-05-01T23:59:59.000Z

150

To forecast short-term load in electric power system based on FNN  

Science Conference Proceedings (OSTI)

Electric power system load forecasting plays an important part in the Energy Management System (EMS), which has a great effect on the operating, controlling and planning of power system. Accurate load forecasting, especially short-term load forecasting, ...

Yueli Hu; Huijie Ji; Xiaolong Song

2009-08-01T23:59:59.000Z

151

Tubular well tool receiving conduit  

SciTech Connect

In combination, a well packer and a tubular well tool receiving conduit are described which consists of: a well packer having an expandable and retractable anchoring teeth and an expandable and retractable seal spaced from the anchoring teeth, a tubular well conduit including, a first plurality of circularly extending grooves on the inside of the conduit for coacting with the anchoring teeth for supporting the well tool in the conduit, a second plurality of circularly extending grooves on the inside of the conduit and positioned for coacting with the expandable seal for providing multiple seal points with the seal.

Durst, D.G.; Morris, A.J.

1986-07-15T23:59:59.000Z

152

Repository receiving facility design support  

Science Conference Proceedings (OSTI)

This report provides preliminary design criteria and proposed design features to reduce the occupational radiation exposure and the transportation turnaround time during receipt of waste shipments at a Federal high-level nuclear waste repository. A cost/benefit analysis is provided. Much of the data presented in previous reports was revised and upgraded to reflect current estimates of waste generation/receipt volumes so as to provide a baseline comparison case for the cost/benefit analysis. The National Waste Repository in Basalt receiving facility operational manpower requirements, estimated occupational dose exposures and capital cost estimates were revised by scaling factors based on the volume receipts. All capital cost estimates were expressed in terms of 1983 dollars. The repository receiving facility was divided into two main areas. The cask handling facility for unloading shipments of spent fuel high-level vitrified wastes and spent fuel cladding hulls, and the TRU-waste handling facility for unloading 55-, 80-, and 600-drum shipments. In both areas, remote handling techniques were employed as much as practical. Occupational dose estimates were formulated based on an operational time and motion survey for truck and rail shipping packages and reference dose maps for each corresponding package. 9 references, 5 figures, 22 tables.

Cottrell, J.E.; Dabolt, R.J.; Steneck, P.D.

1983-07-01T23:59:59.000Z

153

Energy Efficiency Improvement and Cost Saving Opportunities for the Fruit and Vegetable Processing Industry. An ENERGY STAR Guide for Energy and Plant Managers  

E-Print Network (OSTI)

10) System improvements Improved load management MaintenanceSystems Motor management plan Strategic motor selection Maintenance

Masanet, Eric

2008-01-01T23:59:59.000Z

154

WIPP Receives Top Safety Award | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Top Safety Award Top Safety Award WIPP Receives Top Safety Award November 9, 2011 - 12:00pm Addthis Media Contact Deb Gill www.wipp.energy.gov 575-234-7270 CARLSBAD, N.M. - The U.S. Department of Energy's (DOE) Waste Isolation Pilot Plant (WIPP) received top accolades from New Mexico's leading mining organizations. The New Mexico Bureau of Mine Safety (BMS) recently recognized URS Washington TRU Solutions (WTS), LLC, the WIPP management and operating contractor, for receiving the New Mexico Mining Association (NMMA) and New Mexico BMS Safe Operator of the Year Award. "I'm pleased to congratulate Washington TRU Solutions and the WIPP workforce for receiving the state's top mine safety award for 23 of the past 25 years," said Ed Ziemianski, Carlsbad Field Office Interim

155

Argonne CNM Highlight: CNM scientist receives presidential award for  

NLE Websites -- All DOE Office Websites (Extended Search)

scientist receives presidential award for advancement of science scientist receives presidential award for advancement of science Yugang Sun receives a PECASE award Yugang Sun (left) with Dr. Altaf Carim, DOE program manager for the five Nanoscale Science Research Centers, during the December 19, 2008, PECASE award ceremony at DOE headquarters Assistant chemist Yugang Sun received the Presidential Early Career Award for Scientists and Engineers (PECASE) to recognize his contribution to the advancement of science. Dr. Sun, a member of the Nanophotonics Group in Argonne's Center for Nanoscale Materials, was recognized for developing ground-breaking techniques for chemical synthesis and nanofabrication of metal and semiconductor nanomaterials, as well as for community educational activities. The Presidential Awards are intended to recognize and nurture

156

Hanford Projects Receive Sustainability Awards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Projects Receive Sustainability Awards Projects Receive Sustainability Awards Hanford Projects Receive Sustainability Awards June 7, 2011 - 12:00pm Addthis Media Contact Geoff Tyree, DOE (509) 376-4171 Geoffrey.Tyree@rl.doe.gov RICHLAND, WASH. - Hanford's Department of Energy offices and their contractors received special recognition Tuesday for their part in promoting sustainability. The Department of Energy's Office of Environmental Management in Washington D.C. selected 10 Hanford Site projects to be awarded for excellence in encouraging sustainability, conserving resources, and exemplifying the ideals set forth by Executive Order 13514. The Order was signed by President Barack Obama on October 5, 2009, and challenged federal agencies to make plans and lead by example in "environmental, energy, and economic

157

Battery loading device  

SciTech Connect

A battery loading device for loading a power source battery, built in small appliances having a battery loading chamber for selectively loading a number of cylindrical unit batteries or a one body type battery having the same voltage as a number of cylindrical unit batteries, whereby the one body type battery and the battery loading chamber are shaped similarly and asymmetrically in order to prevent the one body type battery from being inserted in the wrong direction.

Phara, T.; Suzuki, M.

1984-08-28T23:59:59.000Z

158

Modeling simple trigeneration systems for the distribution of environmental loads  

Science Conference Proceedings (OSTI)

Integration of thermoeconomics and Life Cycle Analysis was carried out within the framework of an Environmental Management Information System. This combined approach identified where environmental loads were generated and tracked environmental loads ... Keywords: CO2, Environmental Management Information System, Environmental costs, Material flow networks, Trigeneration, Umberto software

Monica Carvalho; Miguel A. Lozano; Luis M. Serra; Volker Wohlgemuth

2012-04-01T23:59:59.000Z

159

Workload-Aware Load Balancing for Clustered Web Servers  

Science Conference Proceedings (OSTI)

We focus on load balancing policies for homogeneous clustered Web servers that tune their parameters on-the-fly to adapt to changes in the arrival rates and service times of incoming requests. The proposed scheduling policy, AdaptLoad, monitors the incoming ... Keywords: Clustered Web servers, self-managing clusters, load balance, locality awareness, workload characterization, static and dynamic pages.

Qi Zhang; Alma Riska; Wei Sun; Evgenia Smirni; Gianfranco Ciardo

2005-03-01T23:59:59.000Z

160

Pantex receives National Weather Service recognition | National...  

National Nuclear Security Administration (NNSA)

Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering...

Note: This page contains sample records for the topic "load management receiver" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH  

E-Print Network (OSTI)

composition: The total load profile obtained from  load individual load types if  load profiles of individual load composition validation: Load profiles generated by the load 

Lesieutre, Bernard

2013-01-01T23:59:59.000Z

162

Exercising flexible load contracts: Two simple strategies  

Science Conference Proceedings (OSTI)

A flexible load contract is a type of swing option where the holder has the right to receive a given quantity of electricity within a specified period, at a fixed maximum effect (delivery rate). The contract is flexible, in the sense that delivery (the ... Keywords: energy, exercise strategy, flexibility, swing option, uncertainty

Petter Bjerksund; Bjarte Myksvoll; Gunnar Stensland

2008-03-01T23:59:59.000Z

163

Fuzzy rule-based methodology for residential load behaviour forecasting during power systems restoration  

Science Conference Proceedings (OSTI)

Inadequate load pickup during power system restoration can lead to overload and underfrequency conditions, and even restart the blackout process, due to thermal energy losses. Thus, load behaviour estimation during restoration is desirable to avoid inadequate ... Keywords: artificial intelligence, energy management systems, fuzzy logic, load behaviour estimation, power system distribution, power system restoration, residential load forecasting, thermostatically controlled loads

Lia Toledo Moreira Mota; Alexandre Assis Mota; Andre Luiz Morelato Franca

2005-04-01T23:59:59.000Z

164

Load Data Analysis and PowerShape Training: Strategic Load Research and Advanced Topics in Load Profiling for Settlements  

Science Conference Proceedings (OSTI)

Load shapes, representing usage patterns in the electric and gas industry, are a key factor in energy company operations and management. In the emerging restructured energy market, retail energy suppliers market energy to final customers and must arrange for electricity generation or gas delivery to meet their customers' needs. EPRI and Primen sponsored a workshop in September 2000 that addressed a range of issues associated with load shapes, including modeling, profiling for retail market settlement, re...

2000-12-20T23:59:59.000Z

165

CALIFORNIA'S NEXT GENERATION OF LOAD MANAGEMENT STANDARDS  

E-Print Network (OSTI)

customer and on the number of participating customers. It is normal practice to assess three types number of customers in the market place. It differs from economic potential, which assumes that all customers accept dynamic pricing. Thus, the key unknown in estimating market potential is the number

166

CALIFORNIA'S NEXT GENERATION OF LOAD MANAGEMENT STANDARDS  

E-Print Network (OSTI)

demand that is reduced per customer and on the number of participating customers. It is normal practice if a cost-effective combination of technologies is accepted by a realistic number of customers in the market, the key unknown in estimating market potential is the number of participating customers. This, of course

167

WIPP contractor receives VPP Legacy of Stars Award 2013  

NLE Websites -- All DOE Office Websites (Extended Search)

Management and Operating Contractor Management and Operating Contractor Recognized for Continuous Safety Performance CARLSBAD, N.M., September 20, 2013 - The U.S. Department of Energy (DOE) recognized Nuclear Waste Partnership LLC (NWP), the Waste Isolation Pilot Plant (WIPP) management and operating (M&O) contractor, with the Voluntary Protection Program (VPP) Legacy of Stars Award in latter August 2013. "Safety is central to everything we do, and achieving this elite designation validates our work and the safety-focused culture we strive to create," said Farok Sharif, NWP President and Project Manager, who received the award with Kevin Miller, United Steel Workers Local Bargaining Unit VPP Ombudsman, at the VPP Participants' Association National Conference

168

A fuzzy logic based approach to direct load control  

SciTech Connect

Demand side management programs are strategies designed to alter the shape of the load curve. In order to successfully implement such a strategy, customer acceptance of the program is vital. It is thus desirable to design a model for direct load control which may accommodate customer preferences. This paper presents a methodology for optimizing both customer satisfaction and utility unit commitment savings, based on a fuzzy load model for the direct load control of appliances.

Bhattacharyya, K.; Crow, M.L. [Univ. of Missouri, Rolla, MO (United States). Dept. of Electrical Engineering

1996-05-01T23:59:59.000Z

169

Load sensing system  

DOE Patents (OSTI)

A load sensing system inexpensively monitors the weight and temperature of stored nuclear material for long periods of time in widely variable environments. The system can include an electrostatic load cell that encodes weight and temperature into a digital signal which is sent to a remote monitor via a coaxial cable. The same cable is used to supply the load cell with power. When multiple load cells are used, vast

Sohns, Carl W. (Oak Ridge, TN); Nodine, Robert N. (Knoxville, TN); Wallace, Steven Allen (Knoxville, TN)

1999-01-01T23:59:59.000Z

170

Automatic Electric Load Identification in  

E-Print Network (OSTI)

Abstract — A microgrid is the power system of choice for the electrification of rural areas in developing countries. It should be able to adapt to changing load situations without the need for specialists to change the configuration of the microgrid controller. This paper proposes a self-configuring microgrid management system that is able to adjust both generation and demand of the system, so that also in case of growing electricity demand the grid can still be operable by disconnecting unessential loads. A crucial task for the microgrid controller is to automatically identify the connected loads on the basis of their consumption behaviors. For this, a template-matching algorithm is proposed that is based on Dynamic Time Warping, which is primarily used in speech recognition. It has been found that for load profile analysis, simple signal features such as the number of rising edges or the aggregated energy consumption in a given time window is sufficient to describe the signal. In contrast to speech recognition, frequency domain analysis is not necessary.

Self-configuring Microgrids; Friederich Kupzog; Tehseen Zia; Adeel Abbas Zaidi

2009-01-01T23:59:59.000Z

171

SLAC National Accelerator Laboratory - SLAC Physicist Receives...  

NLE Websites -- All DOE Office Websites (Extended Search)

Receives Free-electron Laser Award By Glenn Roberts Jr. September 10, 2013 Dao Xiang, a SLAC accelerator physicist, has received an international award for his work on a technique...

172

Trough Receiver Heat Loss Testing (Presentation)  

DOE Green Energy (OSTI)

This presentation describes the design, fabrication, and qualification of an experimental capability for thermal loss testing of full-size trough receiver elements; and the testing on a variety of receivers.

Lewandowski, A.; Feik, C.; Hansen, R.; Phillips, S.; Bingham, C.; Netter, J.; Forristal, R.; Burkholder, F.; Meglan, B.; Wolfrum, E.

2006-02-01T23:59:59.000Z

173

Discharge circuits and loads  

SciTech Connect

This will be an overview in which some of the general properties of loads are examined: their interface with the energy storage and switching devices; general problems encountered with different types of loads; how load behavior and fault modes can impact on the design of a power conditioning system (PCS).

Sarjeant, W.J.

1980-10-15T23:59:59.000Z

174

Pantex receives National Weather Service recognition | National Nuclear  

NLE Websites -- All DOE Office Websites (Extended Search)

National Weather Service recognition | National Nuclear National Weather Service recognition | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > Pantex receives National Weather Service recognition Pantex receives National Weather Service recognition Posted By Office of Public Affairs On the plains of the Texas Panhandle, it pays to be ready for unpredictable

175

Pantex receives two safety awards | National Nuclear Security  

National Nuclear Security Administration (NNSA)

two safety awards | National Nuclear Security two safety awards | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > Pantex receives two safety awards Pantex receives two safety awards Posted By Office of Public Affairs B&W Pantex was honored last week with a pair of awards for its exemplary safety record. The President's Award for Best Performing Business Unit and the Target

176

ITL Staff Members Receive Tech Transfer Award  

Science Conference Proceedings (OSTI)

ITL Staff Members Receive Tech Transfer Award. ... Regional "Excellence in Technology Transfer" Award for ... the process of transferring a technology ...

2010-10-05T23:59:59.000Z

177

DOE Strategic Petroleum Reserve Contractor Receives the Baldrige Award |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DOE Strategic Petroleum Reserve Contractor Receives the Baldrige DOE Strategic Petroleum Reserve Contractor Receives the Baldrige Award DOE Strategic Petroleum Reserve Contractor Receives the Baldrige Award April 19, 2006 - 10:21am Addthis Vice President Cheney Presents DOE contractor with the nation's highest Presidential honor for performance excellence and quality achievement WASHINGTON, DC - Vice President Richard Cheney today presented DynMcDermott Petroleum Operations Company, operator of the U.S. Department of Energy's (DOE) Strategic Petroleum Reserve (SPR), with the 2005 Malcolm Baldrige National Quality Award. The Baldrige award is the nation's highest Presidential honor for performance excellence and quality achievement and is presented annually to organizations that distinguish themselves through management excellence and continuous improvement to stakeholders.

178

Strategic Petroleum Reserve Contractor to Receive 2005 Malcolm Baldrige  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Strategic Petroleum Reserve Contractor to Receive 2005 Malcolm Strategic Petroleum Reserve Contractor to Receive 2005 Malcolm Baldrige National Quality Award Strategic Petroleum Reserve Contractor to Receive 2005 Malcolm Baldrige National Quality Award November 22, 2005 - 2:51pm Addthis Recognition for Management Performance Excellence and Continuous Improvement to Stakeholders WASHINGTON, DC - Secretary of Energy Samuel Bodman today announced that DynMcDermott Petroleum Operations Company, operator of the nation's Strategic Petroleum Reserve (SPR), has been honored with the 2005 Malcolm Baldrige National Quality Award, the nation's highest Presidential honor for quality and organizational performance excellence. President George W. Bush and Commerce Secretary Carlos Gutierrez revealed DynMcDermott's award earlier today, along with five other honorees.

179

DOE Strategic Petroleum Reserve Contractor Receives the Baldrige Award |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Strategic Petroleum Reserve Contractor Receives the Baldrige Strategic Petroleum Reserve Contractor Receives the Baldrige Award DOE Strategic Petroleum Reserve Contractor Receives the Baldrige Award April 19, 2006 - 10:21am Addthis Vice President Cheney Presents DOE contractor with the nation's highest Presidential honor for performance excellence and quality achievement WASHINGTON, DC - Vice President Richard Cheney today presented DynMcDermott Petroleum Operations Company, operator of the U.S. Department of Energy's (DOE) Strategic Petroleum Reserve (SPR), with the 2005 Malcolm Baldrige National Quality Award. The Baldrige award is the nation's highest Presidential honor for performance excellence and quality achievement and is presented annually to organizations that distinguish themselves through management excellence and continuous improvement to stakeholders.

180

DOE Announces First Companies to Receive Industrial Energy Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

First Companies to Receive Industrial Energy First Companies to Receive Industrial Energy Efficiency Certification DOE Announces First Companies to Receive Industrial Energy Efficiency Certification December 9, 2010 - 12:00am Addthis WASHINGTON - The U.S. Department of Energy today announced the first industrial plants in the country to be certified under the Superior Energy Performance program -- a new, market-based industrial energy efficiency program. The energy management certification program is accredited by the American National Standards Institute (ANSI) and will serve as a roadmap for industrial facilities to help continually improve their efficiency and maintain market competitiveness. The industrial and manufacturing sectors, which account for roughly one-third of energy use in the United

Note: This page contains sample records for the topic "load management receiver" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Shipping and Receiving | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Services » Employee Services » Facility Operations » Shipping Services » Employee Services » Facility Operations » Shipping and Receiving Shipping and Receiving Headquarters Receiving Services Information It is our responsibility to get your package to you as quickly as possibly. In order to accomplish this, we must first receive it. However, it is difficult to receive your package if it arrives without being properly addressed. When placing orders with commercial vendors, it is imperative that you let them know the addressees name, mail stop code, room number, location (Forrestal or Germantown) and the address. This information will allow us to receive your order and not reject it. It will also help if you would provide our office with a copy of your purchase order which will assist us in efficiently receiving your order and getting it to you.

182

ENERGY STAR Building Upgrade Manual Chapter 7: Supplemental Load Reduction  

NLE Websites -- All DOE Office Websites (Extended Search)

7: Supplemental Load 7: Supplemental Load Reduction Secondary menu About us Press room Contact Us Portfolio Manager Login Facility owners and managers Existing buildings Commercial new construction Industrial energy management Small business Service providers Service and product providers Verify applications for ENERGY STAR certification Design commercial buildings Energy efficiency program administrators Commercial and industrial program sponsors Associations State and local governments Federal agencies Tools and resources Training In This Section Campaigns Commercial building design Communications resources Energy management guidance Financial resources Portfolio Manager Products and purchasing Recognition Research and reports Service and product provider (SPP) resources Success stories Target Finder

183

Comparison of fixed asymmetrical and symmetrical reflectors for evacuated tube solar receivers  

SciTech Connect

A computer simulation of the relative performance of certain truncated symmetrical and asymmetrical fixed reflector designs for solar energy collection was performed. The comparison was on the basis of annual energy delivered to a circular cylindrical evacuated tube receiver per unit of mirror area, but seasonal load information was also included to determine possible seasonal load matching advantages of one type of collector over another when storage is employed. Circumsolar radiation models based on recent correlations in the literature was included. Major conclusions were that: (1) Annual solar fractions of between 80% and 95% seem to be feasible with a load matching collector used with moderate energy storage, with 80-90% being a likely optimum; (2) CPC reflectors always gave the best annual output performance per unit of mirror area, and the lowest receiver area for situations of constant annual load, regardless of whether the storage is included in the system; (3) Asymmetrical concentrator are more cost-effective for strongly seasonally asymmetrical load patterns; (4) Fixed parabolic systems required much more receiver area than the symmetrical CPC and asymmetrical system investigated; (5) Concentration levels utilizable in fixed systems are higher than previously supposed, with 3.5:1 in an asymmetrical reflector being optimal or nearly optimal for the domestic load pattern used in the study; (6) Using a load matched reflector, the amount of storage required to achieve solar fractions of total thermal energy (space heating, water heating, clothes drying) above 90% in a residence appears to be much lower than previously thought.

Mills, D.R.; Monger, A. (Univ. of Sydney (Australia)); Morrison, G.L. (Univ. of New South Wales, Sydney (Australia))

1994-07-01T23:59:59.000Z

184

Distributed Systems for Energy Management  

NLE Websites -- All DOE Office Websites (Extended Search)

buildings-to-grid, responsive loads, on-line monitoring of efficiency programs, microgrids, and other forms of distributed resource management. A key challenge will be the...

185

Federal Energy Management Program: Training  

NLE Websites -- All DOE Office Websites (Extended Search)

Training Loading the player ... FEMP trains Federal agency managers about the latest energy requirements, best practices, and technologies through eTraining Courses, First...

186

Building Energy Software Tools Directory: Prophet Load Profiler  

NLE Websites -- All DOE Office Websites (Extended Search)

Prophet Load Profiler Prophet Load Profiler Prophet Load Profiler logo. Internet-enabled software that empowers business energy customers to manage energy and reduce costs. Valuable to facility managers, energy managers and energy service companies, the Prophet web-based service delivers real-time and near-real-time energy information on energy consumption and demand for any size facility. A number of facilities can be managed using consumption data gathered in 15 minute, 30 minute, 60 minute, daily, weekly and monthly intervals. Users can immediately view and analyze data with an eye toward load shedding, cost avoidance strategies, energy budget management, utility cost validation and energy forecasting. All tools are contained within the Prophet Web application and enabled via the internet using a standard web

187

Load-shape modeling in southeastern utility systems  

SciTech Connect

Load models are tools which have a wide range of application in the electric-utility industry. Some uses include monitoring load-management policies and helping with on-line commitment problems. The output from a load model can be placed in a suitable software environment where daily load curves are computed and displayed. Also, load models can be extended to perform forecasting functions. A weather sensitive load model that takes into account both weekdays and weekends on an hourly basis has been developed and applied to load shape modeling and short term forecasting on three southeastern electric utilities. A software package associated with the load modeling theory was developed and tested. This load-modeling program computes the daily load curve in terms of identifiable components. The program uses historical hourly load data to compute coefficients related to load components including base, growth, seasonal and weather. These coefficients can be used in a mathematical model to compute an estimate of the daily load curve with load values for each hour of the day. The load-modeling procedure described employs a linear least squares method for computing coefficients in the mathematical model.

Lebby, G.L.

1985-01-01T23:59:59.000Z

188

SunShot Initiative: Advanced Nitrate Salt Central Receiver Power Plant  

NLE Websites -- All DOE Office Websites (Extended Search)

Advanced Nitrate Salt Central Receiver Power Plant Advanced Nitrate Salt Central Receiver Power Plant Abengoa logo Photo of two lit towers surrounded by much smaller blue flat plates that are mounted on the ground. Commercial central receiver plant designs Abengoa, under the Baseload CSP FOA, will demonstrate a 100-megawatt electrical (MWe) central receiver plant using nitrate salt as the receiver coolant, thermal storage medium, and heat transport fluid in the steam generator. Approach The plan is to operate the plant at full load for 6,400 hours each year using only solar energy. Abengoa is working to create a team of suppliers capable of deploying a commercially ready nitrate salt central receiver technology that can be competitive in the current power marketplace. Innovation Abengoa is developing a new molten-salt power tower technology with a surround heliostat field. Key components include:

189

Analysis of the omnium-g receiver  

DOE Green Energy (OSTI)

A thermal analysis of the Omnium-G receiver is presented and the technique is shown to be generally applicable to solar thermal receivers utilizing a directly heated thermal mass. The thermal loss coefficient, including reradiation losses, is calculated and shown to agree quite well with the experimentally measured thermal loss coefficient. The rate of heat transfer to the working fluid is also analyzed and the analysis is used to show that the Omnium-G receiver is well matched to the water/steam working fluid because the steam outlet temperature is almost the same as the receiver temperature. A general procedure for calculating receiver performance is presented. With this procedure, the energy delivery to any working fluid, the delivered temperature of the working fluid, and the pressure drop through the receiver can be determined. An example of the calculation is also presented.

Bohn, M.

1980-03-01T23:59:59.000Z

190

Load sensing system  

DOE Patents (OSTI)

A load sensing system inexpensively monitors the weight and temperature of stored nuclear material for long periods of time in widely variable environments. The system can include an electrostatic load cell that encodes weight and temperature into a digital signal which is sent to a remote monitor via a coaxial cable. The same cable is used to supply the load cell with power. When multiple load cells are used, vast inventories of stored nuclear material can be continuously monitored and inventoried of minimal cost. 4 figs.

Sohns, C.W.; Nodine, R.N.; Wallace, S.A.

1999-05-04T23:59:59.000Z

191

Strategic Petroleum Reserve Receives Prestigious Environmental Award |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Strategic Petroleum Reserve Receives Prestigious Environmental Strategic Petroleum Reserve Receives Prestigious Environmental Award Strategic Petroleum Reserve Receives Prestigious Environmental Award September 22, 2009 - 1:00pm Addthis Washington, DC - The Department of Energy's Office of Fossil Energy (FE) announced today that the Strategic Petroleum Reserve (SPR) has received the Most Valuable Pollution Prevention Project (MVP2) award from the National Pollution Prevention Roundtable for lowering potential greenhouse gas emissions. This is the first time the SPR has captured the award for its commitment to pollution prevention, focusing on innovation, measurable results, transferability, commitment, and optimization of available project resources. "This is another example of the hard work and dedication by employees at

192

Strategic Petroleum Reserve Receives Prestigious Environmental Award |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Strategic Petroleum Reserve Receives Prestigious Environmental Strategic Petroleum Reserve Receives Prestigious Environmental Award Strategic Petroleum Reserve Receives Prestigious Environmental Award September 22, 2009 - 1:00pm Addthis Washington, DC - The Department of Energy's Office of Fossil Energy (FE) announced today that the Strategic Petroleum Reserve (SPR) has received the Most Valuable Pollution Prevention Project (MVP2) award from the National Pollution Prevention Roundtable for lowering potential greenhouse gas emissions. This is the first time the SPR has captured the award for its commitment to pollution prevention, focusing on innovation, measurable results, transferability, commitment, and optimization of available project resources. "This is another example of the hard work and dedication by employees at

193

Substance abuse differences among students receiving special ...  

Science Conference Proceedings (OSTI)

abilities to cope with daily pressures and extended social environ- ments like schools. Typically, children and youth receiving special ed- ucation school services ...

194

Automatic Detection of Unsafe Component Loadings  

E-Print Network (OSTI)

Dynamic loading of software components (e.g., libraries or modules) is a widely used mechanism for improved system modularity and flexibility. Correct component resolution is critical for reliable and secure software execution, however, programming mistakes may lead to unintended or even malicious components to be resolved and loaded. In particular, dynamic loading can be hijacked by placing an arbitrary file with the specified name in a directory searched before resolving the target component. Although this issue has been known for quite some time, it was not considered serious because exploiting it requires access to the local file system on the vulnerable host. Recently such vulnerabilities started to receive considerable attention as their remote exploitation became realistic; it is now important to detect and fix these vulnerabilities. In this paper, we present the first automated technique to detect vulnerable and unsafe dynamic component loadings. Our analysis has two phases: 1) apply dynamic binary instrumentation to collect runtime information on component loading (online phase); and 2) analyze the collected information to detect vulnerable component loadings (offline phase). For evaluation, we implemented our technique to detect vulnerable and unsafe DLL loadings in popular Microsoft Windows software. Our results show that unsafe DLL loading is prevalent and can lead to serious security threats. Our tool detected more than 1,700 unsafe DLL loadings in 28 widely used software and discovered serious attack vectors for remote code execution. Microsoft has opened a Microsoft Security Response Center (MSRC) case on our reported issues and is working with us and other affected software vendors to develop necessary patches.

Taeho Kwon; Zhendong Su

2010-01-01T23:59:59.000Z

195

Structural load combinations  

SciTech Connect

This paper presents the latest results of the program entitled, ''Probability Based Load Combinations For Design of Category I Structures''. In FY 85, a probability-based reliability analysis method has been developed to evaluate safety of shear wall structures. The shear walls are analyzed using stick models with beam elements and may be subjected to dead load, live load and in-plane eqrthquake. Both shear and flexure limit states are defined analytically. The limit state probabilities can be evaluated on the basis of these limit states. Utilizing the reliability analysis method mentioned above, load combinations for the design of shear wall structures have been established. The proposed design criteria are in the load and resistance factor design (LRFD) format. In this study, the resistance factors for shear and flexure and load factors for dead and live loads are preassigned, while the load factor for SSE is determined for a specified target limit state probability of 1.0 x 10/sup -6/ or 1.0 x 10/sup -5/ during a lifetime of 40 years. 23 refs., 9 tabs.

Hwang, H.; Reich, M.; Ellingwood, B.; Shinozuka, M.

1985-01-01T23:59:59.000Z

196

Watershed Mercury Loading Framework  

Science Conference Proceedings (OSTI)

This report explains and illustrates a simplified stochastic framework, the Watershed Mercury Loading Framework, for organizing and framing site-specific knowledge and information on mercury loading to waterbodies. The framework permits explicit treatment of data uncertainties. This report will be useful to EPRI members, state and federal regulatory agencies, and watershed stakeholders concerned with mercury-related human and ecological health risk.

2003-05-23T23:59:59.000Z

197

Classification of total load demand profiles for war-ships based on pattern recognition methods  

Science Conference Proceedings (OSTI)

The classification of total load demand profiles for every type of war-ships is crucial information, because it is the necessary base for a series of studies and operations, such as load estimation, load shedding and power management systems. In this ... Keywords: adequacy measures, clustering algorithms, load profiles, pattern recognition, warship

G. J. Tsekouras; I. S. Karanasiou; F. D. Kanellos

2011-07-01T23:59:59.000Z

198

EPRI/GRI Load Shape Workshop: Load Data Analysis for Gas and Electric Markets  

Science Conference Proceedings (OSTI)

Load shapes, representing usage patterns in the electric and gas industry, are a key factor in energy company operations and management. In the emerging restructured energy market, retail energy suppliers market energy to final customers and must arrange for electricity generation or gas delivery to meet their customers' needs. EPRI and GRI sponsored a two-day workshop in June, 1999 that addressed a range of issues associated with load shapes, including modeling, profiling for retail market settlement, r...

1999-11-10T23:59:59.000Z

199

Dynamic model of power system operation incorporating load control  

SciTech Connect

Load management has been proposed as a means whereby an electric utility can reduce its requirements for additional generation, transmission, and distribution investments, shift fuel dependency from limited to more abundant energy resources, and improve the efficiency of the electric energy system. There exist, however, serious technological and economic questions which must be answered to define the cost trade-offs between initiating a load management strategy or adding additional capacity to meet the load. One aspect of this complex problem is to determine how the load profile might be modified by the load management option being considered. Towards this end, a model has been developed to determine how a power system with an active load control system should be operated to make the best use of its available resources. The model is capable of handling all types of conventional generating sources including thermal, hydro, and pumped storage units, and most appliances being considered for direct control including those with inherent or designed storage characteristics. The model uses a dynamic programming technique to determine the optimal operating strategy for a given set of conditions. The use of the model is demonstrated. Case study results indicate that the production cost savings that can be achieved through the use of direct load control are highly dependent on utility characteristics, load characteristics, storage capacity, and penetration. The load characteristics that produce the greatest savings are: large storage capacity; high coincidence with the system peak; large connected load per point; and moderately high diversity fraction.

Kuliasha, M.A.

1980-10-01T23:59:59.000Z

200

load | OpenEI  

Open Energy Info (EERE)

load load Dataset Summary Description This dataset contains hourly load profile data for 16 commercial building types (based off the DOE commercial reference building models) and residential buildings (based off the Building America House Simulation Protocols). This dataset also includes the Residential Energy Consumption Survey (RECS) for statistical references of building types by location. Source Commercial and Residential Reference Building Models Date Released April 18th, 2013 (9 months ago) Date Updated July 02nd, 2013 (7 months ago) Keywords building building demand building load Commercial data demand Energy Consumption energy data hourly kWh load profiles Residential Data Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Annually

Note: This page contains sample records for the topic "load management receiver" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Liquid cooled fiber thermal radiation receiver  

DOE Patents (OSTI)

A radiation-to-thermal receiver apparatus for collecting radiation and converting it to thermal energy is disclosed. The invention includes a fibrous mat material which captures radiation striking the receiver. Captured radiation is removed from the fibrous mat material by a transparent fluid within which the material is bathed.

Butler, B.L.

1985-03-29T23:59:59.000Z

202

Liquid cooled fiber thermal radiation receiver  

DOE Patents (OSTI)

A radiation-to-thermal receiver apparatus for collecting radiation and converting it to thermal energy is disclosed. The invention includes a fibrous mat material which captures radiation striking the receiver. Captured radiation is removed from the fibrous mat material by a transparent fluid within which the material is bathed.

Butler, Barry L. (Del Mar, CA)

1987-01-01T23:59:59.000Z

203

Property types eligible to receive a 1-100 ENERGY STAR score | ENERGY STAR  

NLE Websites -- All DOE Office Websites (Extended Search)

Identify your property type Identify your property type » Property types eligible to receive a 1-100 ENERGY STAR score Secondary menu About us Press room Contact Us Portfolio Manager Login Facility owners and managers Existing buildings Commercial new construction Industrial energy management Small business Service providers Service and product providers Verify applications for ENERGY STAR certification Design commercial buildings Energy efficiency program administrators Commercial and industrial program sponsors Associations State and local governments Federal agencies Tools and resources Training In this section Learn the benefits Get started Use Portfolio Manager The new ENERGY STAR Portfolio Manager How Portfolio Manager helps you save The benchmarking starter kit Identify your property type Property types eligible to receive a 1-100 ENERGY STAR score

204

A Survey of Load Control Programs for Price and System Stability  

Science Conference Proceedings (OSTI)

Load control and demand side load management programs have been implemented in a large number of competitive power markets. These programs can provide enhanced system security and many benefits to participants. This paper reviews and compares existing economically driven programs.

Jazayeri, P.; Schellenberg, A.; Rosehart, W. D.; Doudna, J.; Widergren, Steven E.; Lawrence, D.; Mickey, J.; Jones, S.

2005-08-01T23:59:59.000Z

205

On loading rate effects in toughening processes  

SciTech Connect

Environmental crack tip reactions are a known source of premature fracture in oxides. These rate-dependent phenomena commonly are studied in strength tests where loading rate serves as the major experimental variable. A material susceptible to environmentally-assisted crack growth is stronger at fast testing rates. A topic which has received far less attention is the influence of stressing rate or loading rate on the shielding processes which occur at some distance from the crack tip, although the inverse has been studied by Deuerler et al. The authors present here the first known documentation of a loading rate effect on shielding phenomena in ceramic materials. For these experiments Coors AD 94 alumina was chosen for study.

Tandon, S.; Faber, K.T. [Northwestern Univ., Evanston, IL (United States)

1996-03-01T23:59:59.000Z

206

Progress in solar thermal distributed receiver technology  

DOE Green Energy (OSTI)

The author reports the status of research on distributed receivers, which are solar thermal collectors which concentrate sunlight on an absorber and do not employ the central receiver concept. Point-focusing collectors such as the parabolic dish, line-focusing collectors such as the parabolic trough, and the fixed-mirror distributed-focus of hemispheric bowl collectors are the most common receivers. Following an overview of fundamental principals, there is a description of several installations and of the organic Rankine Cycle engine and the Solarized Automotive Gas Turbine projects. Future development will explore other types of power cycles, new materials, and other components and designs. 5 references, 6 figures.

Leonard, J.A.; Otts, J.V.

1985-08-01T23:59:59.000Z

207

HLW Glass Waste Loadings  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HLW HLW Glass Waste Loadings Ian L. Pegg Vitreous State Laboratory The Catholic University of America Washington, DC Overview Overview  Vitrification - general background  Joule heated ceramic melter (JHCM) technology  Factors affecting waste loadings  Waste loading requirements and projections  WTP DWPF  DWPF  Yucca Mountain License Application requirements on waste loading  Summary Vitrification  Immobilization of waste by conversion into a glass  Internationally accepted treatment for HLW  Why glass?  Amorphous material - able to incorporate a wide spectrum of elements over wide ranges of composition; resistant to radiation damage  Long-term durability - natural analogs Relatively simple process - amenable to nuclearization at large  Relatively simple process - amenable to nuclearization at large scale  There

208

OpenEI - load  

Open Energy Info (EERE)

are given by a location defined by the Typical Meteorological Year (TMY) for which the weather data was collected. Commercial load data is sorted by the (TMY) site as a...

209

Use of energy management systems for performance monitoring of...  

NLE Websites -- All DOE Office Websites (Extended Search)

Use of energy management systems for performance monitoring of industrial load-shaping measures Title Use of energy management systems for performance monitoring of industrial...

210

building load data | OpenEI Community  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Load data Image source: NREL...

211

electric load data | OpenEI Community  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Load data Image source: NREL...

212

commercial load | OpenEI Community  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Load data Image source: NREL...

213

residential load | OpenEI Community  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Load data Image source: NREL...

214

Impact of Aerosols on Atmospheric Attenuation Loss in Central Receiver Systems: Preprint  

Science Conference Proceedings (OSTI)

Atmospheric attenuation loss between the heliostat field and receiver has been recognized as a significant source of loss in Central Receiver Systems. In clear sky situations, extinction of Direct Normal Irradiance (DNI) is primarily by aerosols in the atmosphere. When aerosol loading is high close to the surface the attenuation loss between heliostat and receivers is significantly influenced by the amount of aerosols present on a particular day. This study relates measured DNI to aerosol optical depths close to the surface of the earth. The model developed in the paper uses only measured DNI to estimate the attenuation between heliostat and receiver in a central receiver system. The requirement that only a DNI measurement is available potentially makes the model a candidate for widespread use.

Sengupta, M.; Wagner, M. J.

2011-08-01T23:59:59.000Z

215

Thermal Resources for Load Management: Understanding Variable Capacity HVAC Systems as a Load Management Resource  

Science Conference Proceedings (OSTI)

Space conditioning accounts for a major portion of the energy consumption in U.S. residences and commercial buildings and is a primary driver of summer and winter peak demand for electric utility companies. The most common type of space conditioning system in the U.S. is some form of an air-source, fixed speed, direct expansion system. For several decades utilities have implemented efficiency and demand response programs involving fixed speed air conditioning. Over the years, there has been a steady rise ..

2013-12-17T23:59:59.000Z

216

Composite Load Model Evaluation  

Science Conference Proceedings (OSTI)

The WECC load modeling task force has dedicated its effort in the past few years to develop a composite load model that can represent behaviors of different end-user components. The modeling structure of the composite load model is recommended by the WECC load modeling task force. GE Energy has implemented this composite load model with a new function CMPLDW in its power system simulation software package, PSLF. For the last several years, Bonneville Power Administration (BPA) has taken the lead and collaborated with GE Energy to develop the new composite load model. Pacific Northwest National Laboratory (PNNL) and BPA joint force and conducted the evaluation of the CMPLDW and test its parameter settings to make sure that: • the model initializes properly, • all the parameter settings are functioning, and • the simulation results are as expected. The PNNL effort focused on testing the CMPLDW in a 4-bus system. An exhaustive testing on each parameter setting has been performed to guarantee each setting works. This report is a summary of the PNNL testing results and conclusions.

Lu, Ning; Qiao, Hong (Amy)

2007-09-30T23:59:59.000Z

217

WIPP Receives Top Mine Safety Award  

NLE Websites -- All DOE Office Websites (Extended Search)

September 18, 2013 - The U.S. Department of Energy's (DOE) Waste Isolation Pilot Plant (WIPP) received top safety honors from the New Mexico Bureau of Mine Safety (BMS) and the New...

218

Atmospheric considerations for central receiver power plants  

DOE Green Energy (OSTI)

This report documents the results of a study of the effects of atmospheric attenuation, turbulent scattering, and the use of cooling towers on the performance of solar thermal central receiver power plants.

Henderson, R.G.; Pitter, R.L.

1979-06-01T23:59:59.000Z

219

One Video Stream to Serve Diverse Receivers  

E-Print Network (OSTI)

The fundamental problem of wireless video multicast is to scalably serve multiple receivers which may have very different channel characteristics. Ideally, one would like to broadcast a single stream that allows each ...

Woo, Grace

2008-10-18T23:59:59.000Z

220

Demand-Side Response from Industrial Loads  

Science Conference Proceedings (OSTI)

Through a research study funded by the Department of Energy, Smart Grid solutions company ENBALA Power Networks along with the Oak Ridge National Laboratory (ORNL) have geospatially quantified the potential flexibility within industrial loads to leverage their inherent process storage to help support the management of the electricity grid. The study found that there is an excess of 12 GW of demand-side load flexibility available in a select list of top industrial facilities in the United States. Future studies will expand on this quantity of flexibility as more in-depth analysis of different industries is conducted and demonstrations are completed.

Starke, Michael R [ORNL; Alkadi, Nasr E [ORNL; Letto, Daryl [Enbala Power Networks; Johnson, Brandon [University of Tennessee, Knoxville (UTK); Dowling, Kevin [University of Tennessee, Knoxville (UTK); George, Raoule [Enbala Power Networks; Khan, Saqib [University of Texas, Austin

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "load management receiver" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Idaho National Laboratory receives national recognition for Small Business  

NLE Websites -- All DOE Office Websites (Extended Search)

Media contacts: Media contacts: Erik Simpson (208) 360-0426 Idaho National Laboratory receives national recognition for Small Business Mentoring Program With the help of American Recovery and Reinvestment Act funds, the Idaho Cleanup Project continues work to protect the Snake River Plain Aquifer this week by injecting grout into 21 buried waste locations in the Subsurface Disposal Area (SDA) of the Radioactive Waste Management Complex (RWMC) at the Department of Energy�s Idaho Site. The project will cost $8.2 million and will reduce the threat of contaminants migrating toward the aquifer by keeping water out of the waste. �Protecting the Snake River Plain Aquifer is a priority at the Idaho Site. Thanks to Recovery Act funds, this grouting work will help ensure the safety of our important natural resource,� said Rick Provencher, manager of DOE�s Idaho Operations Office.

222

A handbook for solar central receiver design  

DOE Green Energy (OSTI)

This Handbook describes central receiver technology for solar thermal power plants. It contains a description and assessment of the major components in a central receiver system configured for utility scale production of electricity using Rankine-cycle steam turbines. It also describes procedures to size and optimize a plant and discussed examples from recent system analyses. Information concerning site selection criteria, cost estimation, construction, and operation and maintenance is also included, which should enable readers to perform design analyses for specific applications.

Falcone, P.K.

1986-12-01T23:59:59.000Z

223

Low-temperature volumetric receiver concept  

SciTech Connect

This document describes an alternative solar central receiver concept that offers the potential for a substantial reduction in the cost of electrical energy. The concept consists of a low temperature volumetric receiver which supplies 1100/degree/F air to a Kalina cycle heat engine. Hot air can also be supplied to a packed bed of Dresser basalt where the hot air is used to heat the bed. The thermal energy stored in the bed can be extracted and supplied to the Kalina cycle during periods of low insolation. Previous investigations of the volumetric receiver concentrated on high temperature applications. The results showed that the volumetric concept could be very efficient, but the receiver was expensive and there were significant technical problems. Areas of technical uncertainty included fiber durability, the feasibility of inducing a preswirl and cost effective applications. The use of the volumetric receiver to produce low temperature will avoid the problems identified in the high temperature studies. The attractiveness of the low temperature concept is enhanced by the availability of the Kalina cycle. This heat engine was developed as a bottoming cycle for Brayton and Rankine cycle power plants. The key feature of the Kalina cycle is its ability to efficiently utilize the energy in a relatively low temperature heat source. The combination of the low temperature volumetric receiver and the Kalina cycle is particularly interesting. 7 refs., 2 figs., 3 tabs.

Drost, M.K.

1988-09-01T23:59:59.000Z

224

Definition: Customer Energy Management Device and System | Open Energy  

Open Energy Info (EERE)

Device and System Device and System Jump to: navigation, search Dictionary.png Customer Energy Management Device and System A device that can control other energy devices such as thermostats, lighting, direct load control devices, or distributed energy resource within the customer premise. These devices may also receive information or control signals from utillities or third party energy service providers. These devices can help customers manage electricity usage automatically by utilizing information from service providers, or preferences set by the customer.[1] Related Terms energy, electricity generation, distributed energy resource References ↑ https://www.smartgrid.gov/category/technology/customer_energy_management_device_and_system [[Cat LikeLike UnlikeLike You like this.Sign Up to see what your friends like.

225

Los Alamos National Laboratory employees receive Pollution Prevention...  

NLE Websites -- All DOE Office Websites (Extended Search)

Employees receive Pollution Prevention awards Los Alamos National Laboratory employees receive Pollution Prevention awards Nearly 400 employees on 47 teams received Pollution...

226

Los Alamos National Laboratory employees receive Pollution Prevention...  

NLE Websites -- All DOE Office Websites (Extended Search)

Employees Receive Pollution Prevention Awards Los Alamos National Laboratory employees receive Pollution Prevention Awards Nearly 400 employees on 47 teams received Pollution...

227

Load Monitoring CEC/LMTF Load Research Program  

SciTech Connect

This white paper addresses the needs, options, current practices of load monitoring. Recommendations on load monitoring applications and future directions are also presented.

Huang, Zhenyu; Lesieutre, B.; Yang, Steve; Ellis, A.; Meklin, A.; Wong, B.; Gaikwad, A.; Brooks, D.; Hammerstrom, Donald J.; Phillips, John; Kosterev, Dmitry; Hoffman, M.; Ciniglio, O.; Hartwell, R.; Pourbeik, P.; Maitra, A.; Lu, Ning

2007-11-30T23:59:59.000Z

228

NETL Researcher Receives Outstanding Technical Achievement Award  

NLE Websites -- All DOE Office Websites (Extended Search)

qualities sought for such awards. She currently serves as the technical coordinator for shale gas research, managing multiple projects within NETL's Office of Research and...

229

Liquid cooled, linear focus solar cell receiver  

DOE Patents (OSTI)

Separate structures for electrical insulation and thermal conduction are established within a liquid cooled, linear focus solar cell receiver for use with parabolic or Fresnel optical concentrators. The receiver includes a V-shaped aluminum extrusion having a pair of outer faces each formed with a channel receiving a string of solar cells in thermal contact with the extrusion. Each cell string is attached to a continuous glass cover secured within the channel with spring clips to isolate the string from the external environment. Repair or replacement of solar cells is effected simply by detaching the spring clips to remove the cover/cell assembly without interrupting circulation of coolant fluid through the receiver. The lower surface of the channel in thermal contact with the cells of the string is anodized to establish a suitable standoff voltage capability between the cells and the extrusion. Primary electrical insulation is provided by a dielectric tape disposed between the coolant tube and extrusion. Adjacent solar cells are soldered to interconnect members designed to accommodate thermal expansion and mismatches. The coolant tube is clamped into the extrusion channel with a releasably attachable clamping strip to facilitate easy removal of the receiver from the coolant circuit.

Kirpich, A.S.

1983-12-08T23:59:59.000Z

230

Liquid cooled, linear focus solar cell receiver  

DOE Patents (OSTI)

Separate structures for electrical insulation and thermal conduction are established within a liquid cooled, linear focus solar cell receiver for use with parabolic or Fresnel optical concentrators. The receiver includes a V-shaped aluminum extrusion having a pair of outer faces each formed with a channel receiving a string of solar cells in thermal contact with the extrusion. Each cell string is attached to a continuous glass cover secured within the channel with spring clips to isolate the string from the external environment. Repair or replacement of solar cells is effected simply by detaching the spring clips to remove the cover/cell assembly without interrupting circulation of coolant fluid through the receiver. The lower surface of the channel in thermal contact with the cells of the string is anodized to establish a suitable standoff voltage capability between the cells and the extrusion. Primary electrical insulation is provided by a dielectric tape disposed between the coolant tube and extrusion. Adjacent solar cells are soldered to interconnect members designed to accommodate thermal expansion and mismatches. The coolant tube is clamped into the extrusion channel with a releasably attachable clamping strip to facilitate easy removal of the receiver from the coolant circuit.

Kirpich, Aaron S. (Broomall, PA)

1985-01-01T23:59:59.000Z

231

Dish/stirling hybrid-receiver  

DOE Green Energy (OSTI)

A hybrid high-temperature solar receiver is provided which comprises a solar heat-pipe-receiver including a front dome having a solar absorber surface for receiving concentrated solar energy, a heat pipe wick, a rear dome, a sidewall joining the front and the rear dome, and a vapor and a return liquid tube connecting to an engine, and a fossil fuel fired combustion system in radial integration with the sidewall for simultaneous operation with the solar heat pipe receiver, the combustion system comprising an air and fuel pre-mixer, an outer cooling jacket for tangentially introducing and cooling the mixture, a recuperator for preheating the mixture, a burner plenum having an inner and an outer wall, a porous cylindrical metal matrix burner firing radially inward facing a sodium vapor sink, the mixture ignited downstream of the matrix forming combustion products, an exhaust plenum, a fossil-fuel heat-input surface having an outer surface covered with a pin-fin array, the combustion products flowing through the array to give up additional heat to the receiver, and an inner surface covered with an extension of the heat-pipe wick, a pin-fin shroud sealed to the burner and exhaust plenums, an end seal, a flue-gas diversion tube and a flue-gas valve for use at off-design conditions to limit the temperature of the pre-heated air and fuel mixture, preventing pre-ignition.

Mehos, Mark S. (Boulder, CO); Anselmo, Kenneth M. (Arvada, CO); Moreno, James B. (Albuquerque, NM); Andraka, Charles E. (Albuquerque, NM); Rawlinson, K. Scott (Albuquerque, NM); Corey, John (Melrose, NY); Bohn, Mark S. (Golden, CO)

2002-01-01T23:59:59.000Z

232

Tiffany A. Blanchard-Case receives 2013 Linton Brooks Medal | National  

National Nuclear Security Administration (NNSA)

Tiffany A. Blanchard-Case receives 2013 Linton Brooks Medal | National Tiffany A. Blanchard-Case receives 2013 Linton Brooks Medal | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > Tiffany A. Blanchard-Case receives 2013 Linton Brooks Medal Tiffany A. Blanchard-Case receives 2013 Linton Brooks Medal Posted By Office of Public Affairs Tiffany A. Blanchard-Case has been selected as the recipient of the 2013

233

Y-12's historian receives 2013 Muddy Boot Award | National Nuclear  

National Nuclear Security Administration (NNSA)

's historian receives 2013 Muddy Boot Award | National Nuclear 's historian receives 2013 Muddy Boot Award | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > Y-12's historian receives 2013 Muddy Boot Award Y-12's historian receives 2013 Muddy Boot Award Posted By Office of Public Affairs Y-12 historian Ray Smith was among the recipients at the recent East

234

Anton Tran receives award from the Air War College | National Nuclear  

National Nuclear Security Administration (NNSA)

Anton Tran receives award from the Air War College | National Nuclear Anton Tran receives award from the Air War College | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > Anton Tran receives award from the Air ... Anton Tran receives award from the Air War College Posted By Office of Public Affairs Anton Tran Anton Tran, from NNSA's Office of Nuclear Weapon Surety and Quality, has

235

Maria Research Reactor loaded with LEU - Otwock, Poland | National Nuclear  

National Nuclear Security Administration (NNSA)

Maria Research Reactor loaded with LEU - Otwock, Poland | National Nuclear Maria Research Reactor loaded with LEU - Otwock, Poland | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > Media Room > Video Gallery > Maria Research Reactor loaded with LEU - ... Maria Research Reactor loaded with LEU - Otwock, Poland Maria Research Reactor loaded with LEU - Otwock, Poland

236

Mass-Loaded Flows  

E-Print Network (OSTI)

A key process within astronomy is the exchange of mass, momentum, and energy between diffuse plasmas in many types of astronomical sources (including planetary nebulae, wind-blown bubbles, supernova remnants, starburst superwinds, and the intracluster medium) and dense, embedded clouds or clumps. This transfer affects the large scale flows of the diffuse plasmas as well as the evolution of the clumps. I review our current understanding of mass-injection processes, and examine intermediate-scale structure and the global effect of mass-loading on a flow. I then discuss mass-loading in a variety of diffuse sources.

J. M. Pittard

2006-07-13T23:59:59.000Z

237

Mudundi R. Raju receives Padma Shri award  

NLE Websites -- All DOE Office Websites (Extended Search)

Mudundi R. Raju receives Padma Shri award Mudundi R. Raju receives Padma Shri award Mudundi R. Raju receives Padma Shri award The government of India honored Mudundi Raju for his distinguished service in science and engineering, providing cancer radiation treatment to the poor of rural India. July 18, 2013 President of India Pranab Mukherjee presents the Padma Shri award to former Los Alamos National Laboratory scientist Mudundi Raju. President of India Pranab Mukherjee presents the Padma Shri award to former Los Alamos National Laboratory scientist Mudundi Raju. Contact Nancy Ambrosiano Communications Office (505) 667-0471 Email "The aim of science is to improve the human condition," said Nobel Laureate Ilya Prigogine, and Raju has taken this statement to heart. Los Alamos retiree brings medical advances to poor of India

238

Windowed versus windowless solar energy cavity receivers  

DOE Green Energy (OSTI)

A model for a windowed, high-temperature cavity receiver of the heated-air type is developed and used to evaluate the greenhouse effect as a method for obtaining high receiver operating efficiencies. The effects on receiver efficiency of varying the window cutoff wavelength, the amount of absorption in the window pass-band, the cavity operating temperature, and the number of windows are determined. Single windowed cavities are found to offer theoretical efficiencies comparable to windowless ones, while multiple windowed units are found to suffer from low operating efficiencies due to losses resulting from reflections at each window/air interface. A ''first order'' examination is made of the feasibility of air cooling the window to assure its survival. This appears possible if a proper combination of cooling technique and window material characteristics is selected.

Jarvinen, P. O.

1976-09-01T23:59:59.000Z

239

Solar Heat-Pipe Receiver Wick Modeling  

DOE Green Energy (OSTI)

Stirling-cycle engines have been identified as a promising technology for the conversion of concentrated solar energy into usable electrical power. In previous experimented work, we have demonstrated that a heat pipe receiver can significantly improve system performance-over a directly-illuminated heater head. The design and operating conditions of a heat pipe receiver differ significantly from typical laboratory heat pipes. New wick structures have been developed to exploit the characteristics of the solar generation system. Typically, these wick structures allow vapor generation within the wick. Conventional heat pipe models do not handle this enhancement yet it can more than double the performance of the wick. In this study, I develop a steady-state model of a boiling-enhanced wick for a solar heat pipe receiver. The model is used for design-point calculations and is written in FORTRAN90. Some limited comparisons have been made with actual test data.

Andraka, C.E.

1998-12-21T23:59:59.000Z

240

Appliance Commitment for Household Load Scheduling  

Science Conference Proceedings (OSTI)

This paper presents a novel appliance commitment algorithm that schedules thermostatically-controlled household loads based on price and consumption forecasts considering users comfort settings to meet an optimization objective such as minimum payment or maximum comfort. The formulation of an appliance commitment problem was described in the paper using an electrical water heater load as an example. The thermal dynamics of heating and coasting of the water heater load was modeled by physical models; random hot water consumption was modeled with statistical methods. The models were used to predict the appliance operation over the scheduling time horizon. User comfort was transformed to a set of linear constraints. Then, a novel linear, sequential, optimization process was used to solve the appliance commitment problem. The simulation results demonstrate that the algorithm is fast, robust, and flexible. The algorithm can be used in home/building energy-management systems to help household owners or building managers to automatically create optimal load operation schedules based on different cost and comfort settings and compare cost/benefits among schedules.

Du, Pengwei; Lu, Ning

2011-06-30T23:59:59.000Z

Note: This page contains sample records for the topic "load management receiver" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Head & base production optimization : inventory management strategy  

E-Print Network (OSTI)

A new inventory management strategy was developed for Schlumberger to reduce waste in material handling and improve the warehouse receiving efficiency. The current warehouse receiving situation was analyzed; then the ...

Guo, Yuming, M. Eng. Massachusetts Institute of Technology

2009-01-01T23:59:59.000Z

242

Cooling load estimation methods  

DOE Green Energy (OSTI)

Ongoing research on quantifying the cooling loads in residential buildings, particularly buildings with passive solar heating systems, is described. Correlations are described that permit auxiliary cooling estimates from monthly average insolation and weather data. The objective of the research is to develop a simple analysis method, useful early in design, to estimate the annual cooling energy required of a given building.

McFarland, R.D.

1984-01-01T23:59:59.000Z

243

LOADING AND UNLOADING DEVICE  

DOE Patents (OSTI)

A device for loading and unloading fuel rods into and from a reactor tank through an access hole includes parallel links carrying a gripper. These links enable the gripper to go through the access hole and then to be moved laterally from the axis of the access hole to the various locations of the fuel rods in the reactor tank.

Treshow, M.

1960-08-16T23:59:59.000Z

244

Multidimensional spectral load balancing  

DOE Patents (OSTI)

A method of and apparatus for graph partitioning involving the use of a plurality of eigenvectors of the Laplacian matrix of the graph of the problem for which load balancing is desired. The invention is particularly useful for optimizing parallel computer processing of a problem and for minimizing total pathway lengths of integrated circuits in the design stage.

Hendrickson, Bruce A. (Albuquerque, NM); Leland, Robert W. (Albuquerque, NM)

1996-12-24T23:59:59.000Z

245

Buildings Stock Load Control  

E-Print Network (OSTI)

Researchers and practitioners have proposed a variety of solutions to reduce electricity consumption and curtail peak demand. This research focuses on electricity demand control by applying some strategies in existing building to reduce it during the extreme climate period. The first part of this paper presents the objectives of the study: ? to restrict the startup polluting manufacturing units (power station), ? to limit the environmental impacts (greenhouse emission), ? to reduce the transport and distribution electricity infrastructures The second part presents the approach used to rise the objectives : ? To aggregat the individual loads and to analyze the impact of different strategies from load shedding to reduce peak power demand by: ? Developing models of tertiary buildings stocks (Schools, offices, Shops, hotels); ? Making simulations for different load shedding strategies to calculate potential peak power saving. The third part is dedicated to the description of the developed models: An assembly of the various blocks of the library of simbad and simulink permit to model building. Finally the last part prensents the study results: Graphs and tables to see the load shedding strategies impacts.

Joutey, H. A.; Vaezi-Nejad, H.; Clemoncon, B.; Rosenstein, F.

2006-01-01T23:59:59.000Z

246

OpenEI Community - load data  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Utility Rate OpenEI Community...

247

OpenEI Community - electric load data  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Utility Rate OpenEI Community...

248

OpenEI Community - building load  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Utility Rate OpenEI Community...

249

OpenEI Community - residential load  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Utility Rate OpenEI Community...

250

OpenEI Community - commercial load  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Utility Rate OpenEI Community...

251

OpenEI Community - building load data  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Utility Rate OpenEI Community...

252

Prepaid Services Full-time students receive  

E-Print Network (OSTI)

with a medical provider · Unlimited nutritional consultations with RD #12;Prepaid Services · Health education for student only #12;PUSH Services Allergy and Immunizations Laboratory Radiology Physical Therapy Sports#12;Prepaid Services Full-time students receive: · Unlimited visits to medical clinic to consult

Holland, Jeffrey

253

Solar Central Receiver with an Irising Aperture  

E-Print Network (OSTI)

Variable sun elevation, azimuthal and declination angles with the time of day, and seasons of the year respectively, give variable projected image size defects produced by field site concave mirrors on the central cavity receiver's aperture entrance. If the aperture is small, it will be inefficient for periods when the solar isolation is inclined due to spillage. However, if the aperture is large, it will be inefficient for periods when the solar isolation is normal, due to excess heat radiation and convection losses. Thus, the fixed aperture area size is a compromise between ideal sizes for different conditions. The end result is a loss of efficiency as a function of time of day and seasons of the year. This research presents an approach to maximize the interception factor on the receiver entrance, with reducing the heat losses by radiation and convection through its aperture area. A central receiver system, having a down-looking cavity with an irises aperture is being proposed for application in rich environmental solar conditions, utilized solar flux insolation throughout the day on the city of Kuwait. Solar tower focusing collector with a cavity type receiver having a fixed area aperture at the entrance is presented for comparison with the proposed technique. This collector is proved to be less efficient than the suggested design. The isiring cavity receiver with a variable area aperture provides an approximately constant efficiency regardless of the time of day or season of the year. The end result is the proposed system shows improved performance and capability. However, over the life-time of installation these advantages of the proposed system should overweigh its disadvantages of additional cost due to extra automation.

Galal, T.; Kulaib, A. M.; Abuzaid, M.

2010-01-01T23:59:59.000Z

254

Local graduate receives B&W four-year scholarship | Y-12 National Security  

NLE Websites -- All DOE Office Websites (Extended Search)

Local graduate receives ... Local graduate receives ... Local graduate receives B&W four-year scholarship Posted: September 5, 2013 - 4:02pm Babcock & Wilcox recently announced the 2013 B&W Scholarship recipients, and Deputy General Manager of Operations Dave Richardson (left in photo) was on hand at Y-12's New Hope Center to congratulate Bearden High School graduate Sheri Cunningham (center). Cunningham is the daughter of B&W Y-12 engineer Penny Cunningham (right in photo). Scholarships were awarded based on academic achievement, Scholastic Aptitude Test or American College Test scores, financial need and the relevance of the student's course of study to the company's business. Cunningham will receive $1,500 per year for up to four years of college-level study. Her application was one of more than 100 received and

255

facilities management | OpenEI Community  

Open Energy Info (EERE)

reviews buildings technology comfort energy use facilities management green building LEED technologies usgbc Syndicate content 429 Throttled (bot load) Error 429 Throttled (bot...

256

Load Capacity of Bodies  

E-Print Network (OSTI)

For the stress analysis in a plastic body $\\Omega$, we prove that there exists a maximal positive number $C$, the \\emph{load capacity ratio,} such that the body will not collapse under any external traction field $t$ bounded by $Y_{0}C$, where $Y_0$ is the elastic limit. The load capacity ratio depends only on the geometry of the body and is given by $$ \\frac{1}{C}=\\sup_{w\\in LD(\\Omega)_D} \\frac{\\int_{\\partial\\Omega}|w|dA} {\\int_{\\Omega}|\\epsilon(w)|dV}=\\left\\|\\gamma_D\\right\\|. $$ Here, $LD(\\Omega)_D$ is the space of isochoric vector fields $w$ for which the corresponding stretchings $\\epsilon(w)$ are assumed to be integrable and $\\gamma_D$ is the trace mapping assigning the boundary value $\\gamma_D(w)$ to any $w\\in LD(\\Omega)_D$.

Reuven Segev

2005-11-01T23:59:59.000Z

257

Load responsive hydrodynamic bearing  

Science Conference Proceedings (OSTI)

A load responsive hydrodynamic bearing is provided in the form of a thrust bearing or journal bearing for supporting, guiding and lubricating a relatively rotatable member to minimize wear thereof responsive to relative rotation under severe load. In the space between spaced relatively rotatable members and in the presence of a liquid or grease lubricant, one or more continuous ring shaped integral generally circular bearing bodies each define at least one dynamic surface and a plurality of support regions. Each of the support regions defines a static surface which is oriented in generally opposed relation with the dynamic surface for contact with one of the relatively rotatable members. A plurality of flexing regions are defined by the generally circular body of the bearing and are integral with and located between adjacent support regions. Each of the flexing regions has a first beam-like element being connected by an integral flexible hinge with one of the support regions and a second beam-like element having an integral flexible hinge connection with an adjacent support region. A least one local weakening geometry of the flexing region is located intermediate the first and second beam-like elements. In response to application of load from one of the relatively rotatable elements to the bearing, the beam-like elements and the local weakening geometry become flexed, causing the dynamic surface to deform and establish a hydrodynamic geometry for wedging lubricant into the dynamic interface.

Kalsi, Manmohan S. (Houston, TX); Somogyi, Dezso (Sugar Land, TX); Dietle, Lannie L. (Stafford, TX)

2002-01-01T23:59:59.000Z

258

ICCS questions received by March 19, 2010  

NLE Websites -- All DOE Office Websites (Extended Search)

questions received by March 19, 2010 questions received by March 19, 2010 1. Is property tax on land or equipment directly attributable to the project eligible for cost share? 2. Is insurance, with coverage comparable to that purchased for similar projects, eligible for cost share (construction and operating)? Response: The answer to both questions is yes. The specific cost principle that the Applicants can go to for further information, as well as the regulations on cost sharing are given below. Question 1 - FAR Part 31.205-41, Taxes Question 2 - FAR Part 31.205-19, Insurance and Indemnification Cost Sharing regulations - 10 CFR 600.123; 10 CFR 600.224; or 10 CFR 600.313 Since both questions indicate that the costs to be incurred will be used as potential cost share for the project, additional details will be needed to verify and validate the

259

Questions Received February 17-18  

NLE Websites -- All DOE Office Websites (Extended Search)

Received February 17-18 Received February 17-18 1. I am formally requesting information on the length of the entire CCS Program. a. Is there a minimum time requirement on the Demonstration portion of the project? There is no specific minimum duration for the Demonstration Phase. However, projects will be evaluated on their ability to meet DOE's target of capture and sequestration of one million tons of CO 2 per year. Another objective of the program is to demonstrate geologic sequestration options in a variety of geologic settings in order to evaluate costs, operational processes, and technical performance. Excessively short Demonstration Phase durations will not assist DOE in meetings its objectives, and will be taken into consideration during the evaluation.

260

Central Receiver Test Facility (CRTF) experiment manual  

DOE Green Energy (OSTI)

The Central Receiver Test Facility is operated by Sandia Laboratories for the US Department of Energy. The CRTF is being used for component and subsystem evaluation within the Solar Thermal Large Power Systems Program. This experiment manual provides users of the CRTF detailed information about: (1) implementation of testing at the CRTF; (2) details of the CRTF capabilities and interfaces, and (3) requirements of experimenters.

Holmes, J. T.; Matthews, L. K.; Seamons, L. O.; Davis, D. B.; King, D. L.

1979-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "load management receiver" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Radio Astronomy Software Defined Receiver Project  

SciTech Connect

The paper describes a Radio Astronomy Software Defined Receiver (RASDR) that is currently under development. RASDR is targeted for use by amateurs and small institutions where cost is a primary consideration. The receiver will operate from HF thru 2.8 GHz. Front-end components such as preamps, block down-converters and pre-select bandpass filters are outside the scope of this development and will be provided by the user. The receiver includes RF amplifiers and attenuators, synthesized LOs, quadrature down converters, dual 8 bit ADCs and a Signal Processor that provides firmware processing of the digital bit stream. RASDR will interface to a user s PC via a USB or higher speed Ethernet LAN connection. The PC will run software that provides processing of the bit stream, a graphical user interface, as well as data analysis and storage. Software should support MAC OS, Windows and Linux platforms and will focus on such radio astronomy applications as total power measurements, pulsar detection, and spectral line studies.

Vacaliuc, Bogdan [ORNL; Leech, Marcus [Shirleys Bay Radio Astronomy Consortium; Oxley, Paul [Retired; Flagg, Richard [Retired; Fields, David [ORNL

2011-01-01T23:59:59.000Z

262

Waste receiving and processing plant control system; system design description  

Science Conference Proceedings (OSTI)

The Plant Control System (PCS) is a heterogeneous computer system composed of numerous sub-systems. The PCS represents every major computer system that is used to support operation of the Waste Receiving and Processing (WRAP) facility. This document, the System Design Description (PCS SDD), includes several chapters and appendices. Each chapter is devoted to a separate PCS sub-system. Typically, each chapter includes an overview description of the system, a list of associated documents related to operation of that system, and a detailed description of relevant system features. Each appendice provides configuration information for selected PCS sub-systems. The appendices are designed as separate sections to assist in maintaining this document due to frequent changes in system configurations. This document is intended to serve as the primary reference for configuration of PCS computer systems. The use of this document is further described in the WRAP System Configuration Management Plan, WMH-350, Section 4.1.

LANE, M.P.

1999-02-24T23:59:59.000Z

263

Carbon Characterization Laboratory Readiness to Receive Irradiated Graphite Samples  

SciTech Connect

The Carbon Characterization Laboratory (CCL) is located in Labs C19 and C20 of the Idaho National Laboratory Research Center. The CCL was established under the Next Generation Nuclear Plant Project to support graphite and ceramic composite research and development activities. The research conducted in this laboratory will support the Advanced Graphite Creep experiments—a major series of material irradiation experiments within the Next Generation Nuclear Plant Graphite program. The CCL is designed to characterize and test low activated irradiated materials such as high purity graphite, carbon-carbon composites, silicon-carbide composite, and ceramic materials. The laboratory is fully capable of characterizing material properties for both irradiated and nonirradiated materials. Major infrastructural modifications were undertaken to support this new radiological facility at Idaho National Laboratory. Facility modifications are complete, equipment has been installed, radiological controls and operating procedures have been established and work management documents have been created to place the CCL in readiness to receive irradiated graphite samples.

Karen A. Moore

2011-05-01T23:59:59.000Z

264

Combined transmission distribution load flow model employing system reduction and voltage variable load representation  

SciTech Connect

In the few decades since its introduction the digital computer has found widespread application within the electric power industry. One of the more fruitful areas for its utilization has been in the determination of the steady-state voltage conditions throughout the system. A power system naturally breaks down into two very distinct parts: transmission and distribution, and traditionally, the voltage problem has been separated the same way. In the transmission system it is referred to as a load flow problem, and in the distribution part it is called a voltage profile. In addition, the loads are often treated differently. Transmission loads are usually considered to be constant power, and the equations that result are therefore nonlinear. In the distribution portion the loads, though specified in terms of power, are sometimes handled as constant impedances, with linear equations. This work produced a new model wherein a mesh transmission system is combined with a radial distribution system and they are solved simultaneously. A system reduction technique is used to eliminate part of the transmission system from consideration, and thereby keep the problem at a manageable size. The solution algorithm incorporates a voltage variable load model which approximates the behavior of real loads more nearly than the common representations.

Enouen, P.W.

1985-01-01T23:59:59.000Z

265

Variable loading roller  

DOE Patents (OSTI)

An automatic loading roller for transmitting torque in traction drive devices in manipulator arm joints includes a two-part camming device having a first cam portion rotatable in place on a shaft by an input torque and a second cam portion coaxially rotatable and translatable having a rotating drive surface thereon for engaging the driven surface of an output roller with a resultant force proportional to the torque transmitted. Complementary helical grooves in the respective cam portions interconnected through ball bearings interacting with those grooves effect the rotation and translation of the second cam portion in response to rotation of the first. 14 figs.

Williams, D.M.

1988-01-21T23:59:59.000Z

266

Advanced motor driven clamped borehole seismic receiver  

DOE Patents (OSTI)

A borehole seismic tool is described including a borehole clamp which only moves perpendicular to the borehole. The clamp is driven by an electric motor, via a right angle drive. When used as a seismic receiver, the tool has a three part housing, two of which are hermetically sealed. Accelerometers or geophones are mounted in one hermetically sealed part, the electric motor in the other hermetically sealed part, and the clamp and right angle drive in the third part. Preferably the tool includes cable connectors at both ends. Optionally a shear plate can be added to the clamp to extend the range of the tool.

Engler, B.P.; Sleefe, G.E.; Striker, R.P.

1993-02-23T23:59:59.000Z

267

A passion for physics, Zoe Martin, receives exposure to real...  

NLE Websites -- All DOE Office Websites (Extended Search)

for physics student receives exposure to real-world science A passion for physics, Zoe Martin, receives exposure to real-world science Physics undergraduate runs computer...

268

Y-12 receives American Heart Association award | Y-12 National...  

NLE Websites -- All DOE Office Websites (Extended Search)

receives American ... Y-12 receives American Heart Association award Posted: November 22, 2012 - 9:00am Kathy Jetton, senior regional director of the American Heart Association,...

269

Chemical Scientist Hendrik Bluhm Receives Bessel Research Award  

NLE Websites -- All DOE Office Websites (Extended Search)

Chemical Scientist Hendrik Bluhm Receives Bessel Research Award Chemical Scientist Hendrik Bluhm Receives Bessel Research Award Print Friday, 24 May 2013 00:00 Hendrik Bluhm of the...

270

Laser warning receiver to identify the wavelength and angle of ...  

A laser warning receiver is disclosed which has up to hundreds of individual optical channels each optically oriented to receive laser light from a different angle of ...

271

Pantex receives Perkins Award in recognition of its work with...  

NLE Websites -- All DOE Office Websites (Extended Search)

Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > Pantex receives Perkins Award in recognition of ... Pantex receives Perkins Award in...

272

WIPP Receives First Shipment | National Nuclear Security Administratio...  

National Nuclear Security Administration (NNSA)

NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > About Us > Our History > NNSA Timeline > WIPP Receives First Shipment WIPP Receives...

273

Sixty-seven New Mexico students receive LAESF scholarships  

NLE Websites -- All DOE Office Websites (Extended Search)

April Sixty-seven New Mexico students receive LAESF scholarships LAESF scholarships winners Taos High School senior Majdolene Khweis received this year's platinum scholarship,...

274

Federal Identity Management Handbook  

NLE Websites -- All DOE Office Websites (Extended Search)

Federal Identity Management Handbook Federal Identity Management Handbook Version 0.1 December 2005 VERSION 0.1 Federal Identity Management Handbook Acknowledgements The Office of Management and Budget and the Federal Identity Credentialing Committee would like to acknowledge the significant contributions of the National Institute of Standards and Technology (NIST) and the Government Smart Card Interagency Advisory Board (IAB) for providing valuable contributions to the development of this handbook. A special thanks goes out to those who participated in the various workshops and provided valuable subject matter expertise and lessons learned. The comments received from other government and industry organizations are also acknowledged. VERSION 0.1 i

275

Solar central receiver heliostat reflector assembly  

SciTech Connect

A heliostat reflector assembly for a solar central receiver system comprises a light-weight, readily assemblable frame which supports a sheet of stretchable reflective material and includes mechanism for selectively applying tension to and positioning the sheet to stretch it to optical flatness. The frame is mounted on and supported by a pipe pedestal assembly that, in turn, is installed in the ground. The frame is controllably driven in a predetermined way by a light-weight drive system so as to be angularly adjustable in both elevation and azimuth to track the sun and efficiently continuously reflect the sun's rays to a focal zone, i.e. central receiver, which forms part of a solar energy utilization system, such as a solar energy fueled electrical power generation system. The frame may include a built-in system for testing for optical flatness of the reflector. The preferable geometric configuration of the reflector is octagonal; however, it may be other shapes, such as hexagonal, pentagonal or square. Several different embodiments of means for tensioning and positioning the reflector to achieve optical flatness are disclosed. The reflector assembly is based on the stretch frame concept which provides an extremely light-weight, simple, low-cost reflector assembly that may be driven for positioning and tracking by a light-weight, inexpensive drive system.

Horton, Richard H. (Schenectady, NY); Zdeb, John J. (Clifton Park, NY)

1980-01-01T23:59:59.000Z

276

DOE receives title to Great Plains plant  

Science Conference Proceedings (OSTI)

On June 30, 1986 the Great Plains Coal Gasification Project was sold at a foreclosure sale at the Mercer County courthouse in North Dakota. The US Department of Energy was the only bidder at the sale. DOE's bid for the plant was $1 billion DOE-secured loan that the five sponsor companies defaulted on when they withdrew from the project in August 1985. DOE did not receive title to the plant until a lawsuit filed by American Natural Resources (ANR) was settled on July 14, 1986. DOE has vowed to keep the plant running as long as it does not cost the taxpayers any money. Eventually DOE wishes to dispose of the plant. Therefore, in February 1986 DOE requested that interested organizations submit expressions of interest in the Great Plains plant. This paper, after discussing the lawsuit, summarizes the nine responses received by DOE. Some companies were willing for it to remain a coal gasification facility; other submitted plans for modifications to produce methanol.

Not Available

1986-09-01T23:59:59.000Z

277

Parabolic Trough Receiver Heat Loss Testing (Poster)  

DOE Green Energy (OSTI)

Parabolic trough receivers, or heat collection elements (HCEs), absorb sunlight focused by the mirrors and transfer that thermal energy to a fluid flowing within them. Thje absorbing tube of these receivers typically operates around 400 C (752 F). HCE manufacturers prevent thermal loss from the absorbing tube to the environment by using sputtered selective Cermet coatings on the absorber and by surrounding the absorber with a glass-enclosed evacuated annulus. This work quantifies the heat loss of the Solel UVAC2 and Schott PTR70 HCEs. At 400 C, the HCEs perform similarly, losing about 400 W/m of HCE length. To put this in perspective, the incident beam radiation on a 5 m mirror aperture is about 4500 W/m, with about 75% of that energy ({approx} 3400 W/m) reaching the absorber surface. Of the 3400 W/m on the absorber, about 3000 W/m is absorbed into the working fluid while 400 W/m is lost to the environment.

Price, H.; Netter, J.; Bingham, C.; Kutscher, C.; Burkholder, F.; Brandemuehl, M.

2007-03-01T23:59:59.000Z

278

Monitoring of Electrical End-Use Loads in Commercial Buildings  

E-Print Network (OSTI)

Southern California Edison is currently conducting a program to collect end-use metered data from commercial buildings in its service area. The data will provide actual measurements of end-use loads and will be used in research and in designing energy management programs oriented toward end-use applications. The focus of the program is on five major types of commercial buildings: offices, grocery stores, restaurants, retail stores, and warehouses. End-use metering equipment is installed at about 50 buildings, distributed among these five types. The buildings selected have average demands of 100 to 300 kW. The metered end-uses vary among building types and include HVAC, lighting, refrigeration. plug loads, and cooking. Procedures have been custom-designed to facilitate collection and validation of the end-use load data. For example, the Load Profile Viewer is a PC-based software program for reviewing and validating the end-use load data.

Martinez, M.; Alereza, T.; Mort, D.

1988-01-01T23:59:59.000Z

279

End-Use Load-Shape Estimation: Methods and Validation  

Science Conference Proceedings (OSTI)

In developing effective demand-side management plans and load forecasts, utilities need information on customer hourly load patterns over a range of end-uses. Such information may be obtained using the two methods described in this report for disaggregating whole-building load data. Both methods have been validated using end-use metered data. This report is available only to funders of Program 101A or 101.001. Funders may download this report at http://my.primen.com/Applications/DE/Community/index.asp .

1991-02-01T23:59:59.000Z

280

Load as a reliability resource in restructured electricity markets  

Science Conference Proceedings (OSTI)

Recent electricity price spikes demonstrate the value that demand-side responses could bring to a restructured US electricity system. This report considers how even a modest increase in demand elasticity could dramatically reduce these extremes in price volatility. The report provides a three-part assessment addressing the ability of customer's load to participate in competitive markets and the current and potential future role of customer loads as system reliability resources. The study begins by evaluating the extent to which customer loads might be able to provide electricity reliability or ancillary services and reviewing aspects of a large utility's direct load control program. The second phase of the assessment contains a survey of ways in which load has been used as a system reliability resource focusing on programs triggered by system conditions and a real-time price signal. It reviews the experience of: (1) the California ISO's Demand Relief and Participating Load programs; (2) Interruptible load programs in California; (3) the New England ISO's Load Management program; and (4) a ''mature'' program in New Zealand. The third phase of the assessment examines the status of the underlying metering, communication, and control technologies used to effect customer responses. The final section of the report provides a vision of how the future might look and uses it to outline a program of needed R&D to increase the role of customer loads as system reliability resources. Key elements of this research program include: addressing the needs of system operators, making effective use of load management assets, making use of new program design concepts, the design of end-use technologies, and benefiting from program experiences.

Kueck, J.D.; Kirby, B.J.; Eto, J.; Staunton, R.H.; Marnay, C.; Martinez, A.; Goldman, C.

2001-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "load management receiver" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Fire Safety Tests for Cesium-Loaded Spherical Resorcinol Formaldehyde Resin: Data Summary Report  

SciTech Connect

A draft safety evaluation of the scenario for spherical resorcinol formaldehyde (SRF) resin fire inside the ion exchange column was performed by the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Fire Safety organization. The result of this draft evaluation suggested a potential change of the fire safety classification for the Cesium Ion Exchange Process System (CXP) emergency elution vessels, equipment, and piping. To resolve this question, the fire properties of the SRF resin were measured by Southwest Research Institute (SwRI) through a subcontract managed by Pacific Northwest National Laboratory (PNNL). The results of initial fire safety tests on the SRF resin were documented in a previous report (WTP-RPT-218). The present report summarizes the results of additional tests performed by SwRI on the cesium-loaded SRF resin. The efforts by PNNL were limited to summarizing the test results provided by SwRI into one consolidated data report. The as-received SwRI report is attached to this report in the Appendix A. Where applicable, the precision and bias of each test method, as given by each American Society for Testing and Materials (ASTM) standard procedure, are included and compared with the SwRI test results of the cesium-loaded SRF resin.

Kim, Dong-Sang; Schweiger, Michael J.; Peterson, Reid A.

2012-09-01T23:59:59.000Z

282

MTS Table Top Load frame  

NLE Websites -- All DOE Office Websites (Extended Search)

MTS Table Top Load frame MTS Table Top Load frame The Non-destructive Evaluation group operates an MTS Table Top Load frame for ultimate strength and life cycle testing of various ceramic, ceramic-matrix (FGI), carbon, carbon fiber, cermet (CMC) and metal alloy engineering samples. The load frame is a servo-hydraulic type designed to function in a closed loop configuration under computer control. The system can perform non-cyclic, tension, compression and flexure testing and cyclic fatigue tests. The system is comprised of two parts: * The Load Frame and * The Control System. Load Frame The Load Frame (figure 1) is a cross-head assembly which includes a single moving grip, a stationary grip and LVDT position sensor. It can generate up to 25 kN (5.5 kip) of force in the sample under test and can

283

Impact of Minimum Load Operation on Steam Turbines  

Science Conference Proceedings (OSTI)

Some utilities, as part of a fleet management strategy, are keeping baseload-design plants that are not competitive for 24/7 dispatch at minimum loads to increase their ability to respond to changing demand. Units being operated this way face some associated risks and may see an additional drop in availability, further exacerbating supply management issues and increasing O&M costs. This report seeks to capture ...

2013-11-05T23:59:59.000Z

284

NNSA National Security Campus Receives LEED® Gold Certification...  

National Nuclear Security Administration (NNSA)

Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering...

285

Self locking coupling mechanism for engaging and moving a load  

DOE Patents (OSTI)

A coupling mechanism for engaging and lifting a load has a housing with a guide passage for receiving a knob which is secured to the load through a neck of smaller diameter. A hollow ball in the housing has an opening which receives the knob and the ball is then turned to displace the opening from the housing passage and to cause the neck to enter a slot in the ball thereby securing the load to the coupling mechanism as elements of the housing block travel of the neck back into the opening when the ball is turned to the load holding orientation. As engagement of the load and locking of the coupling mechanism are accomplished simultaneously by the same ball motion, operation is simplified and reliability is greatly increased. The ball is preferably turned by a motor through worm gearing and the coupling mechanism may be controlled from a remote location. Among other uses, the coupling mechanism is adaptable to the handling of spent nuclear reactor fuel elements.

Wood, R.L.; Casamajor, A.B.; Parsons, R.E.

1980-09-12T23:59:59.000Z

286

Receiver control for the Submillimeter Array  

E-Print Network (OSTI)

Efficient operation of a submillimeter interferometer requires remote (preferably automated) control of mechanically tuned local oscillators, phase-lock loops, mixers, optics, calibration vanes and cryostats. The present control system for these aspects of the Submillimeter Array (SMA) will be described. Distributed processing forms the underlying architecture. In each antenna cabin, a serial network of up to ten independent 80C196 microcontroller boards attaches to the real-time PowerPC computer (running LynxOS). A multi-threaded, gcc-compiled program on the PowerPC accepts top-level requests via remote procedure calls (RPC), subsequently dispatches tuning commands to the relevant microcontrollers, and regularly reports the system status to optical-fiber-based reflective memory for common access by the telescope monitor and error reporting system. All serial communication occurs asynchronously via encoded, variable-length packets. The microcontrollers respond to the requested commands and queries by accessing non-volatile, rewriteable lookup-tables (when appropriate) and executing embedded software that operates additional electronic devices (DACs, ADCs, etc.). Since various receiver hardware components require linear or rotary motion, each microcontroller also implements a position servo via a one-millisecond interrupt service routine which drives a DC-motor/encoder combination that remains standard across each subsystem.

T. R. Hunter; R. W. Wilson; R. Kimberk; P. S. Leiker; R. D. Christensen

2005-09-26T23:59:59.000Z

287

Integrated solar receiver/biomass gasifier research  

SciTech Connect

Processes for producing liquid fuels from olefin-rich pyrolysis gases obtained from fast pyrolysis of biomass are being developed by J. Kuester at Arizona State University and J. Diebold at the Naval Weapons Center, China Lake, Calif. In the Diebold process the biomass, carried by steam, is blown through an entrained bed gasifier. The olefins are then separated from the rest of the reaction products and polymerized thermally to gasoline; the other gases are used as fuel for the process. The Kuester process uses a fluidized bed gasifier and a catalytic Fischer-Tropsch reactor which converts the olefins, hydrogen, and carbon monoxide into n-propanol and paraffinic hydrocarbons. The advantages over the Diebold process are shorter residence time and elimination of the gas separation requirement. One disadvantage is the low octane rating of the fuel. As part of the solar thermal program at the Solar Energy Research Institute (SERI), an entrained bed reactor/receiver for fast pyrolysis of biomass is being developed for use with either the Diebold or Kuester process. This system is discussed.

Benham, C.; Bergeron, P.; Bessler, G.; Bohn, M.

1979-11-01T23:59:59.000Z

288

Alaska Village Electric Load Calculator  

DOE Green Energy (OSTI)

As part of designing a village electric power system, the present and future electric loads must be defined, including both seasonal and daily usage patterns. However, in many cases, detailed electric load information is not readily available. NREL developed the Alaska Village Electric Load Calculator to help estimate the electricity requirements in a village given basic information about the types of facilities located within the community. The purpose of this report is to explain how the load calculator was developed and to provide instructions on its use so that organizations can then use this model to calculate expected electrical energy usage.

Devine, M.; Baring-Gould, E. I.

2004-10-01T23:59:59.000Z

289

High-Power Rf Load  

DOE Patents (OSTI)

A compact high-power RF load comprises a series of very low Q resonators, or chokes [16], in a circular waveguide [10]. The sequence of chokes absorb the RF power gradually in a short distance while keeping the bandwidth relatively wide. A polarizer [12] at the input end of the load is provided to convert incoming TE.sub.10 mode signals to circularly polarized TE.sub.11 mode signals. Because the load operates in the circularly polarized mode, the energy is uniformly and efficiently absorbed and the load is more compact than a rectangular load. Using these techniques, a load having a bandwidth of 500 MHz can be produced with an average power dissipation level of 1.5 kW at X-band, and a peak power dissipation of 100 MW. The load can be made from common lossy materials, such as stainless steel, and is less than 15 cm in length. These techniques can also produce loads for use as an alternative to ordinary waveguide loads in small and medium RF accelerators, in radar systems, and in other microwave applications. The design is easily scalable to other RF frequencies and adaptable to the use of other lossy materials.

Tantawi, Sami G. (San Mateo, CA); Vlieks, Arnold E. (Livermore, CA)

1998-09-01T23:59:59.000Z

290

Maximizing efficiency of solar-powered systems by load matching  

Science Conference Proceedings (OSTI)

Solar power is an important source of renewable energy for many low-power systems. Matching the power consumption level with the supply level can make a great difference in the efficiency of power utilization. This paper proposes a source-tracking power ... Keywords: load matching, photovoltaics, power management, power model, solar energy, solar-aware

Dexin Li; Pai H. Chou

2004-08-01T23:59:59.000Z

291

Selecting a Control Strategy for Plug and Process Loads  

Science Conference Proceedings (OSTI)

Plug and Process Loads (PPLs) are building loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the building occupants. PPLs in commercial buildings account for almost 5% of U.S. primary energy consumption. On an individual building level, they account for approximately 25% of the total electrical load in a minimally code-compliant commercial building, and can exceed 50% in an ultra-high efficiency building such as the National Renewable Energy Laboratory's (NREL) Research Support Facility (RSF) (Lobato et al. 2010). Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. A complex array of technologies that measure and manage PPLs has emerged in the marketplace. Some fall short of manufacturer performance claims, however. NREL has been actively engaged in developing an evaluation and selection process for PPLs control, and is using this process to evaluate a range of technologies for active PPLs management that will cap RSF plug loads. Using a control strategy to match plug load use to users' required job functions is a huge untapped potential for energy savings.

Lobato, C.; Sheppy, M.; Brackney, L.; Pless, S.; Torcellini, P.

2012-09-01T23:59:59.000Z

292

California Santa Cruz THREAT MANAGEMENT  

E-Print Network (OSTI)

University of California Santa Cruz THREAT MANAGEMENT Personal Safety Handbook UCSC Police www2 Department Safety Handbook - 15 - #12;Any supervisor, manager, or other person in authority who receives the key to maintenance or delivery people. Don't hide a key outdoors; burglars know all the hiding places

California at Santa Cruz, University of

293

Photovoltaic power converter system with a controller configured to actively compensate load harmonics  

DOE Patents (OSTI)

Photovoltaic power converter system including a controller configured to reduce load harmonics is provided. The system comprises a photovoltaic array and an inverter electrically coupled to the array to generate an output current for energizing a load connected to the inverter and to a mains grid supply voltage. The system further comprises a controller including a first circuit coupled to receive a load current to measure a harmonic current in the load current. The controller includes a second circuit to generate a fundamental reference drawn by the load. The controller further includes a third circuit for combining the measured harmonic current and the fundamental reference to generate a command output signal for generating the output current for energizing the load connected to the inverter. The photovoltaic system may be configured to compensate harmonic currents that may be drawn by the load.

de Rooij, Michael Andrew (Clifton Park, NY); Steigerwald, Robert Louis (Burnt Hills, NY); Delgado, Eladio Clemente (Burnt Hills, NY)

2008-12-16T23:59:59.000Z

294

Procurement and Property Management  

NLE Websites -- All DOE Office Websites (Extended Search)

Doing Business with... Doing Business with... Brookhaven National Laboratory (BNL) Procurement and Property Management provides customers with timely, cost-effective procurement and property management services integrated with and supporting the Laboratory's science, technology and cleanup missions in accordance with the prime contract and customer expectations. Services Include: Procurement of high quality supplies and services that meet customer requirements, Identification and control of government property, Maintaining an efficient stores operation, Expeditious shipping, receiving and delivery services. PPM Has Moved! We are located at: 44 Ramsey Road Shirley, NY 11967 Directions Procurement Property Management Purchasing System Approval (pdf) Personal Property Approval (pdf)

295

Management Plan Management Plan  

E-Print Network (OSTI)

of a coevolving naturalcultural system. Suitable ecosystem attributes can be achieved by managing human maintenance that protects the riparian corridor. · Manage recreational use to protect riparian values Creek and the Warm Springs River during runoff periods. · Road systems and upland management practices

296

ENVIRONMENTAL MANAGEMENT OFFICE OF ENVIRONMENTAL MANAGEMENT  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

ENVIRONMENTAL ENVIRONMENTAL MANAGEMENT OFFICE OF ENVIRONMENTAL MANAGEMENT OFFICE OF ENVIRONMENTAL MANAGEMENT OFFICE OF EM Recovery NEWS FLASH RECOVERY.GOV March 10, 2011 American Recovery and Reinvestment Act Payments Surge Past $4 Billion U.S. Depar tment of Energy | Office of Environmental Management For More Information on EM Recovery Act Work, Visit Us on the Web: http://www.em.doe.gov/emrecovery/ FINANCIAL HIGHLIGHTS * More than $4 BILLION in Recovery Act payments are accelerating environmental cleanup * 67% of EM Recovery Act funds have been paid Financial data are based on reporting as of March 9, 2011, and are subject to change. EM has made more than $4 billion in Recovery Act payments, or 32 percent of the DOE's $12.4 billion in Recovery Act payments. DOE received $35.2 billion

297

Static identification of delinquent loads  

E-Print Network (OSTI)

The effective use of processor caches is crucial to the performance of applications. It has been shown that cache misses are not evenly distributed throughout a program. In applications running on RISC-style processors, a small number of delinquent load instructions are responsible for most of the cache misses. Identification of delinquent loads is the key to the success of many cache optimization and prefetching techniques. In this paper, we propose a method for identifying delinquent loads that can be implemented at compile time. Our experiments over eighteen benchmarks from the SPEC suite shows that our proposed scheme is stable across benchmarks, inputs, and cache structures, identifying an average of 10 % of the total number of loads in the benchmarks we tested that account for over 90 % of all data cache misses. As far as we know, this is the first time a technique for static delinquent load identification with such a level of precision and coverage has been reported. While comparable techniques can also identify load instructions that cover 90 % of all data cache misses, they do so by selecting over 50 % of all load instructions in the code, resulting in a high number of false positives. If basic block profiling is used in conjunction with our heuristic, then our results show that it is possible to pin down just 1.3 % of the load instructions that account for 82 % of all data cache misses. 1.

Vlad-mihai Panait; Amit Sasturkar Ý

2004-01-01T23:59:59.000Z

298

LOAD FORECASTING Eugene A. Feinberg  

E-Print Network (OSTI)

's electricity price forecasting model, produces forecast of gas demand consistent with electric load. #12Gas demand Council's Market Price of Electricity Forecast Natural GasDemand Electric Load Aggregating Natural between the natural gas and electricity and new uses of natural gas emerge. T natural gas forecasts

Feinberg, Eugene A.

299

Surgeons’ and Emergency Physicians’ Perceptions of Trauma Management and Training  

E-Print Network (OSTI)

have received additional training in trauma as a resident?should have received less training in trauma as a resident.of Trauma Management and Training Robin R. Hemphill, MD, MPH

Hemphill, Robin R; Santen, Sally A; Heavrin, Benjamin S

2009-01-01T23:59:59.000Z

300

2012 Load as a Resource Program Peer Review | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Load as a Resource Program Peer Review Load as a Resource Program Peer Review 2012 Load as a Resource Program Peer Review The Transmission Reliability R&D Load as a Resource (LAAR) Program peer review included 8 presentations on September 20, 2012 at Lawrence Berkeley National Lab. Agenda and presentations are below. 2012 LAAR Program Peer Review - Agenda 2012 LAAR Program Peer Review - Frequency Response Demand - Jeff Dagle, PNNL 2012 LAAR Program Peer Review - Frequency Responsive Load Evaluation and Benefits - Isabelle Snyder, ORNL 2012 LAAR Program Peer Review - Load as a Regulation Resource, Phase 2 - Sila Kiliccote, LBNL 2012 LAAR Program Peer Review - Scoping Study on Industrial Regulation - Nasr Alkadi, ORNL 2012 LAAR Program Peer Review - Integration and Extension of Direct Load Management of Smart Loads - Anna Scaglioni, UC Davis

Note: This page contains sample records for the topic "load management receiver" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Monitoring of electrical end-use loads in commercial buildings  

Science Conference Proceedings (OSTI)

A California utility is currently conducting a program to collect end-use metered data from commercial buildings in its service area. The data will provide actual measurements of end-use loads and will be used in research and in designing energy management programs oriented toward end-use applications. The focus of the program is on five major types of commercial buildings: offices, grocery stores, restaurants, retail stores, and warehouses. End-use metering equipment is installed at about 50 buildings selected have average demands of 100kW to 300 kW. The metered end-uses vary among building types and include HVAC, lighting, refrigeration, plug loads, and cooking. Procedures have been custom-designed to facilitate collection and validation of the end-use load data. PC-based software programs have been developed for reviewing and validating the end-sue load data and for generating reports.

Martinez, M. (Southern California Edison, CA (US)); Alereza, T.; Mort, D. (ADM Associates, Sacramento, CA (US))

1989-01-01T23:59:59.000Z

302

building load | OpenEI  

Open Energy Info (EERE)

load load Dataset Summary Description This dataset contains hourly load profile data for 16 commercial building types (based off the DOE commercial reference building models) and residential buildings (based off the Building America House Simulation Protocols). This dataset also includes the Residential Energy Consumption Survey (RECS) for statistical references of building types by location. Source Commercial and Residential Reference Building Models Date Released April 18th, 2013 (9 months ago) Date Updated July 02nd, 2013 (7 months ago) Keywords building building demand building load Commercial data demand Energy Consumption energy data hourly kWh load profiles Residential Data Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Annually

303

Wind load reduction for heliostats  

DOE Green Energy (OSTI)

This report presents the results of wind-tunnel tests supported through the Solar Energy Research Institute (SERI) by the Office of Solar Thermal Technology of the US Department of Energy as part of the SERI research effort on innovative concentrators. As gravity loads on drive mechanisms are reduced through stretched-membrane technology, the wind-load contribution of the required drive capacity increases in percentage. Reduction of wind loads can provide economy in support structure and heliostat drive. Wind-tunnel tests have been directed at finding methods to reduce wind loads on heliostats. The tests investigated primarily the mean forces, moments, and the possibility of measuring fluctuating forces in anticipation of reducing those forces. A significant increase in ability to predict heliostat wind loads and their reduction within a heliostat field was achieved.

Peterka, J.A.; Hosoya, N.; Bienkiewicz, B.; Cermak, J.E.

1986-05-01T23:59:59.000Z

304

Sixty-Eight Students to Receive Nuclear Energy Scholarships and...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Sixty-Eight Students to Receive Nuclear Energy Scholarships and Fellowships Sixty-Eight Students to Receive Nuclear Energy Scholarships and Fellowships July 17, 2013 - 10:30am...

305

Characterization of Advanced Avalanche Photodiodes for Water Vapor Lidar Receivers  

Science Conference Proceedings (OSTI)

Development of advanced differential absorption lidar (DIAL) receivers is very important to increase the accuracy of atmospheric water vapor measurements. A major component of such receivers is the optical detector. In the near-infrared wavelength range ...

Refaat Tamer F.; Halama Gary E.; DeYoung Russell J.

2000-07-01T23:59:59.000Z

306

SunShot Initiative: Advanced Nitrate Salt Central Receiver Power...  

NLE Websites -- All DOE Office Websites (Extended Search)

Advanced Nitrate Salt Central Receiver Power Plant to someone by E-mail Share SunShot Initiative: Advanced Nitrate Salt Central Receiver Power Plant on Facebook Tweet about SunShot...

307

Y-12 inventors receive awards | Y-12 National Security Complex  

NLE Websites -- All DOE Office Websites (Extended Search)

inventors receive ... Y-12 inventors receive awards Posted: February 20, 2013 - 10:31am OAK RIDGE, Tenn. - At the ninth annual Y-12 Technology Transfer awards ceremony held to...

308

Pantex receives two safety awards | National Nuclear Security...  

NLE Websites -- All DOE Office Websites (Extended Search)

Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > Pantex receives two safety awards Pantex receives two safety awards Posted By Office of...

309

NREL: Concentrating Solar Power Research - Receiver R&D  

NLE Websites -- All DOE Office Websites (Extended Search)

used to analyze the steady-state, off-sun thermal losses of receivers used in solar parabolic trough power plants; helps to reduce collector optical losses and reduce receiver...

310

NREL: Wind Research - Baring-Gould Receives Champion Award from...  

NLE Websites -- All DOE Office Websites (Extended Search)

Baring-Gould Receives Champion Award from Women of Wind Energy May 20, 2013 Wind Powering America National Technical Director Ian Baring-Gould received the Champion Award at the...

311

Development of a solar thermal receiver for high temperature applications  

DOE Green Energy (OSTI)

A thermal receiver for point focus collectors is being constructed. Its design, which is based upon experience with a commercial receiver, employs the advantages of that receiver and improves some of its features. The new receiver uses as a buffer between the cavity surface and the heat transfer fluid a thermal mass, which with a very small temperature drop penalty smooths the flux distribution to eliminate hot spots. Maximum operating temperature range was extended from 620/sup 0/C to 870/sup 0/C and receiver efficiency was improved. The design of the receiver enables significant spillage flux at the receiver to be used. Thus, lower quality optics can be employed in applications not requiring very high temperatures. Design and construction features of the receiver are presented and the testing program is described.

Bohn, M.; Bessler, G.

1979-11-01T23:59:59.000Z

312

Operational Monitoring of Weather Radar Receiving Chain Using the Sun  

Science Conference Proceedings (OSTI)

A method for operational monitoring of a weather radar receiving chain, including the antenna gain and the receiver, is presented. The “online” method is entirely based on the analysis of sun signals in the polar volume data produced during ...

Iwan Holleman; Asko Huuskonen; Mikko Kurri; Hans Beekhuis

2010-01-01T23:59:59.000Z

313

Designing CPV Receivers With Reliability: Early Evaluation of Components  

E-Print Network (OSTI)

Designing CPV Receivers With Reliability: Early Evaluation of Components Objective Materials from power electronics industry must be proven when integrated in PV applications. Pre-qualification tests improves the receiver design and reliability. ANU microconcentrator test&design experience

314

LLNL receives accolades from EPA's Federal Green Challenge  

NLE Websites -- All DOE Office Websites (Extended Search)

713green 05172013 LLNL receives accolades from EPA's Federal Green Challenge Jennie L Doman, LLNL, (925) 423-2216, doman3@llnl.gov Printer-friendly LLNL has received accolades...

315

Pantex receives Perkins Award in recognition of its work with women-owned  

National Nuclear Security Administration (NNSA)

Perkins Award in recognition of its work with women-owned Perkins Award in recognition of its work with women-owned small businesses | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > Pantex receives Perkins Award in recognition of ... Pantex receives Perkins Award in recognition of its work with women-owned small businesses

316

Los Alamos National Laboratory receives Department of Energy...  

NLE Websites -- All DOE Office Websites (Extended Search)

DOE environmental sustainability award Los Alamos National Laboratory receives Department of Energy environmental sustainability award EStar awards recognize excellence in...

317

Dixson and Fu Receive NIST Applied Research Award  

Science Conference Proceedings (OSTI)

Dixson and Fu Receive NIST Applied Research Award. For Immediate Release: December 1, 1999. *. Bookmark and Share. ...

2013-07-19T23:59:59.000Z

318

John Cahn to Receive 2011 Kyoto Prize For Fundamental ...  

Science Conference Proceedings (OSTI)

John Cahn to Receive 2011 Kyoto Prize For Fundamental Contributions to Materials Science. For Immediate Release: June 24, 2011. ...

2011-06-27T23:59:59.000Z

319

John Cahn to Receive 2011 Kyoto Prize for Fundamental ...  

Science Conference Proceedings (OSTI)

John Cahn to Receive 2011 Kyoto Prize for Fundamental Contributions to Materials Science. From NIST Tech Beat: July 6, 2011. ...

2011-07-06T23:59:59.000Z

320

Procurement and Property Management  

NLE Websites -- All DOE Office Websites (Extended Search)

Traffic Management Services Plum Island Constructed 1827 Traffic Management Services Plum Island Constructed 1827 Shipping and Receiving Supervisor: M. White Phone: 631-344-2300 Email: mwhite@bnl.gov Traffic Management Services include the following: Transportation Services. Provide guidance on methods of shipment, carrier availability, and discount programs for moving freight for the account of the U. S. Government. Employee Relocation Program. Coordinate the movement of household goods for BNL employees. Receipt and Inspection of goods. Provide the services necessary to ensure that goods are received, inspected, and delivered on time. Ensure that damages are noted at time of delivery and establish claims as necessary. Import/Export Services. Provide guidance on the requirements for shipments made by the Laboratory to destinations outside the continental United States. Obtain Export Licenses as needed.

Note: This page contains sample records for the topic "load management receiver" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Integrated models of distribution transformers and their loads for three-phase power flow analyses  

Science Conference Proceedings (OSTI)

This paper introduces integrated models of distribution transformers and their loads for three-phase power flow analyses. All transformer connections can be easily included, such as single-phase, open wye, open delta and three-phase. For an existing three-phase power flow program without rigorous transformer models, only a slight modification of this program is needed to analyze distribution systems in more detail by using these proposed models. For those with rigorous transformer models, the rigorous transformer models usually make the program converge with difficulty, or even diverge. The convergence characteristics of these program can be dramatically improved if proposed integrated models are used instead of the rigorous transformer models. Moreover, these models can be easily applied by some functions of advanced distribution management systems or automatic mapping and facility management systems, such as transformer load management and feeder load management, to evaluate the individual phase loads along a feeder.

Chen, T.H.; Chang, Y.L. [National Taiwan Inst. of Tech., Taipei (Taiwan, Province of China). Dept. of Electrical Engineering

1996-01-01T23:59:59.000Z

322

load data | OpenEI Community  

Open Energy Info (EERE)

51 51 Varnish cache server Home Groups Community Central Green Button Applications Developer Utility Rate FRED: FRee Energy Database More Public Groups Private Groups Features Groups Blog posts Content Stream Documents Discussions Polls Q & A Events Notices My stuff Energy blogs 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation: XID: 2142234851 Varnish cache server load data Home Sfomail's picture Submitted by Sfomail(48) Member 17 May, 2013 - 12:03 Commercial and Residential Hourly Load Data Now Available on OpenEI! building load building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Load data Image source: NREL Files: application/zip icon System Advisor Model Tool for Downloading Load Data

323

Control and Optimization Meet the Smart Power Grid - Scheduling of Power Demands for Optimal Energy Management  

E-Print Network (OSTI)

The smart power grid aims at harnessing information and communication technologies to enhance reliability and enforce sensible use of energy. Its realization is geared by the fundamental goal of effective management of demand load. In this work, we envision a scenario with real-time communication between the operator and consumers. The grid operator controller receives requests for power demands from consumers, with different power requirement, duration, and a deadline by which it is to be completed. The objective is to devise a power demand task scheduling policy that minimizes the grid operational cost over a time horizon. The operational cost is a convex function of instantaneous power consumption and reflects the fact that each additional unit of power needed to serve demands is more expensive as demand load increases.First, we study the off-line demand scheduling problem, where parameters are fixed and known. Next, we devise a stochastic model for the case when demands are generated continually and sched...

Koutsopoulos, Iordanis

2010-01-01T23:59:59.000Z

324

Spinning Reserve from Responsive Load  

SciTech Connect

As power system costs rise and capacity is strained demand response can provide a significant system reliability benefit at a potentially attractive cost. The 162 room Music Road Hotel in Pigeon Forge Tennessee agreed to host a spinning reserve test. The Tennessee Valley Authority (TVA) supplied real-time metering and monitoring expertise to record total hotel load during both normal operations and testing. Preliminary testing showed that hotel load can be curtailed by 22% to 37% depending on the outdoor temperature and the time of day. The load drop was very rapid, essentially as fast as the 2 second metering could detect.

Kueck, John D [ORNL; Kirby, Brendan J [ORNL; Laughner, T [Tennessee Valley Authority (TVA); Morris, K [Tennessee Valley Authority (TVA)

2009-01-01T23:59:59.000Z

325

Micropower RF transponder with superregenerative receiver and RF receiver with sampling mixer  

DOE Patents (OSTI)

A micropower RF transponder employs a novel adaptation of the superregenerative receiver wherein the quench oscillator is external to the regenerative transistor. The quench oscillator applies an exponentially decaying waveform rather than the usual sinewave to achieve high sensitivity at microampere current levels. Further improvements include circuit simplifications for antenna coupling, extraction of the detected signal, and a low-voltage bias configuration that allows operation with less than a 1-volt rail voltage. The inventive transponder is expected to operate as long as the battery shelf life. 13 figs.

McEwan, T.E.

1997-05-13T23:59:59.000Z

326

Micropower RF transponder with superregenerative receiver and RF receiver with sampling mixer  

DOE Patents (OSTI)

A micropower RF transdponder employs a novel adaptation of the superregenerative receiver wherein the quench oscillator is external to the regenerative transistor. The quench oscillator applies an exponentially decaying waveform rather than the usual sinewave to achieve high sensitivity at microampere current levels. Further improvements include circuit simplifications for antenna coupling, extraction of the detected signal, and a low-voltage bias configuration that allows operation with less than a 1-volt rail voltage. The inventive transponder is expected to operate as long as the battery shelf life.

McEwan, Thomas E. (Livermore, CA)

1997-01-01T23:59:59.000Z

327

Brief A decomposition approach for the solution of the unit loading problem in hydroplants  

Science Conference Proceedings (OSTI)

This paper presents a decomposition approach for the solution of the dynamic programming formulation of the unit loading problem in hydroplant management. This decomposition approach allows the consideration of network and canal constraints without additional ... Keywords: Decomposition, Dynamic programming, Hydroelectricity, Unit loading problem

MichèLe Breton; Saeb Hachem; Abdelghani Hammadia

2002-03-01T23:59:59.000Z

328

An Automatic Load Sharing Approach for a DFIG Based Wind Generator in a Microgrid  

E-Print Network (OSTI)

An Automatic Load Sharing Approach for a DFIG Based Wind Generator in a Microgrid M. A. Barik and H.ravishankar@unsw.edu.au Abstract--The aim of this paper is to manage the load variation of a microgrid by controlling the wind by simulating a benchmark microgrid test system. Simulation results show that the proposed control scheme

Pota, Himanshu Roy

329

Savannah River Operations Office Interim Management of Nuclear...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Disposition of Excess Weapons Plutonium; the Office of Technology Assessment's 1993 report, Dismantling the Bomb and Managing the Nuclear Materials; comments received during the...

330

Solar Central Receiver Hybrid Power Systems sodium-cooled receiver concept. Final report. Volume III. Appendices  

DOE Green Energy (OSTI)

The overall, long term objective of the Solar Central Receiver Hybrid Power System is to identify, characterize, and ultimately demonstrate the viability and cost effectiveness of solar/fossil, steam Rankine cycle, hybrid power systems that: (1) consist of a combined solar central receiver energy source and a nonsolar energy source at a single, common site, (2) may operate in the base, intermediate, and peaking capacity modes, (3) produce the rated output independent of variations in solar insolation, (4) provide a significant savings (50% or more) in fuel consumpton, and (5) produce power at the minimum possible cost in mills/kWh. It is essential that these hybrid concepts be technically feasible and economically competitive with other systems in the near to mid-term time period (1985-1990) on a commercial scale. The program objective for Phase I is to identify and conceptually characterize solar/fossil steam Rankine cycle, commercial-scale, power plant systems that are economically viable and technically feasible. This volume contains appendices to the conceptual design and systems analysis studies gien in Volume II, Books 1 and 2. (WHK)

None

1980-01-01T23:59:59.000Z

331

Advanced nonintrusive load monitoring system  

E-Print Network (OSTI)

There is a need for flexible, inexpensive metering technologies that can be deployed in many different monitoring scenarios. Individual loads may be expected to compute information about their power consumption. Utility ...

Wichakool, Warit, 1977-

2011-01-01T23:59:59.000Z

332

OpenEI - building load  

Open Energy Info (EERE)

are given by a location defined by the Typical Meteorological Year (TMY) for which the weather data was collected. Commercial load data is sorted by the (TMY) site as a...

333

Permanent Load Shift Control Strategies  

NLE Websites -- All DOE Office Websites (Extended Search)

of Permanent Load Shifting for HVAC and other storage assets as it relates to summer on-peak demand, how it can be dynamically and autonomously controlled, and its relationship...

334

Building load control and optimization  

E-Print Network (OSTI)

Researchers and practitioners have proposed a variety of solutions to reduce electricity consumption and curtail peak demand. This research focuses on load control by improving the operations in existing building HVAC ...

Xing, Hai-Yun Helen, 1976-

2004-01-01T23:59:59.000Z

335

Management Programs  

NLE Websites -- All DOE Office Websites (Extended Search)

3MS Environment and Waste Management Programs Environment and Waste Management Programs Environment and Waste Management Programs AN L-934 Surveillance of Site A and Plot M...

336

Management Programs  

NLE Websites -- All DOE Office Websites (Extended Search)

Environment and Waste Management Programs Environment and Waste Management Programs Environment and Waste Management Programs AN L-9213 Surveillance of Site A and Plot M Report...

337

Management Programs  

NLE Websites -- All DOE Office Websites (Extended Search)

r Environment and Waste Management Programs Environment and Waste Management Programs Environment and Waste Management Programs ANL-949 Surveillance of Site A and Plot M Report...

338

Low-cost load research for electric utilities  

Science Conference Proceedings (OSTI)

Golden Valley Electric Association (GVEA) developed two pragmatic approaches to meet most load-research objectives at a substantially lower cost than would be incurred with traditional techniques. GVEA serves three customer classes, with most of its load in the Fairbanks area. GVEA's new approaches simulate load curves for individual customer classes to the degree necessary to meet most load-research objectives for the utility, including applications to cost-of-service analysis, rate design, demand-side management, and load forecasting. These approaches make class load-shape information available to utilities that cannot otherwise afford to develop such data. Although the two approaches were developed for a small utility, they are likely to work at least as well for medium and large utilities. The first approach simulates class curves by combining load data from system feeders with information on customer mix and energy usage. GVEA's supervisory control and data acquisition system gives hourly data on feeder loads, and its billing database provides the number of customers and kilowatt-hour usage by customer class on each feeder. The second approach enhances load-research results by redefining target parameters. Data from several like-hours are used to calculate substitutes for the parameters traditionally defined from single-hour data points. The precision of peak responsibility estimates, for example, can be improved if several of the highest hourly demands in a given time period are used rather than the single highest hourly demand. Arguably, use of several highest hourly demands can also improve the reliability of the allocation of responsibility.

Gray, D.A.; Butcher, M.

1994-08-01T23:59:59.000Z

339

Power management system  

DOE Patents (OSTI)

A method of managing power resources for an electrical system of a vehicle may include identifying enabled power sources from among a plurality of power sources in electrical communication with the electrical system and calculating a threshold power value for the enabled power sources. A total power load placed on the electrical system by one or more power consumers may be measured. If the total power load exceeds the threshold power value, then a determination may be made as to whether one or more additional power sources is available from among the plurality of power sources. At least one of the one or more additional power sources may be enabled, if available.

Algrain, Marcelo C. (Peoria, IL); Johnson, Kris W. (Washington, IL); Akasam, Sivaprasad (Peoria, IL); Hoff, Brian D. (East Peoria, IL)

2007-10-02T23:59:59.000Z

340

Peak Load Management of Thermal Loads Using Advanced Thermal Energy Storage Technologies  

Science Conference Proceedings (OSTI)

Almost 50% of electric energy delivered to residences is converted into some sort of thermal energy—hot water, air conditioning, and refrigeration. Storing energy in thermal form is cheaper especially when the medium used to store the energy is an end-use medium for example, hot water. This technical update evaluates two different technologies for storing energy—in cold water and in hot water.GreenPeak technology, a storage condensing unit (SCU) from IE Technologies, uses an ...

2013-12-20T23:59:59.000Z

Note: This page contains sample records for the topic "load management receiver" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Peak Load Management of Thermal Loads Using Thermal Energy Storage Technologies  

Science Conference Proceedings (OSTI)

This Electric Power Research Institute (EPRI) technical update reviews the technology of storing energy in hot water. The report presents test results from three strategies that can be implemented using a grid connected controller to control the heating elements in a water heater. A separate section analyzes utility Supervisory Control and Data Acquisition (SCADA) data to study the impact of renewable generation on conventional generation. The report also includes a hypothetical case developed for ...

2012-12-21T23:59:59.000Z

342

Estimating catchment-scale impacts of wildfire on sediment and nutrient loads using the E2 catchment modelling framework  

Science Conference Proceedings (OSTI)

Approximately 1.3 million ha of forested and agricultural land in south-eastern Australia was burnt by wildfires in early 2003. This paper describes a modelling process to assess the impacts of the fires on the quality of receiving waters and river systems ... Keywords: Catchment modelling, E2, Nutrient loads, Sediment loads, Water quality, Wildfire

Paul M. Feikema; Gary J. Sheridan; Robert M. Argent; Patrick N. J. Lane; Rodger B. Grayson

2011-07-01T23:59:59.000Z

343

{Control of Residential Load Management Networks Using Real Time Pricing  

E-Print Network (OSTI)

Static Setback Demand Response . . . . . . . . . . . . . . .Mitigation Demand Response . . . . . . . . . . . . . . .Cost Ratio Demand Response . . . . . . . . . . . . . . . .

Burke, William Jerome

2010-01-01T23:59:59.000Z

344

Sandia's research spans generation, storage, and load management at  

E-Print Network (OSTI)

LBNL-62315 Optimal Technology Selection and Operation of Commercial- Building Microgrids Chris Technology Solutions with funding provided by the California Energy Commission, Public Interest Energy, process, or service by its trade name, trademark, manufacturer, or otherwise, does not necessarily

345

Sandia's research spans generation, storage, and load management at  

E-Print Network (OSTI)

Contract No. DE-AC03-76SF00098 and by the California Energy Commission, Public Interest Energy Research, process, or service by its trade name, trademark, manufacturer, or otherwise, does not necessarily: distributed generation; combined heat and power; decentralised optimisation; microgrid; power quality ABSTRACT

346

ELECTRICAL LOAD MANAGEMENT FOR THE CALIFORNIA WATER SYSTEM  

E-Print Network (OSTI)

Growth Fertility Rates a Immigration Agricultural Production National Population b Foreign Trade c Crop Yields d Power Plant

Krieg, B.

2010-01-01T23:59:59.000Z

347

ELECTRICAL LOAD MANAGEMENT FOR THE CALIFORNIA WATER SYSTEM  

E-Print Network (OSTI)

DWR Bulletin 194. Hydroelectric Energy Potential inmore than 6 bil- of hydroelectric poweL of view of energyfrom peak demand Daytime hydroelectric Two wate:r age) would

Krieg, B.

2010-01-01T23:59:59.000Z

348

{Control of Residential Load Management Networks Using Real Time Pricing  

E-Print Network (OSTI)

The interconnected smart grid promises many advantages toplays a key role in the smart grid’s ability to deliver onSimulation To ensure the smart grid truly is “smart” before

Burke, William Jerome

2010-01-01T23:59:59.000Z

349

ELECTRICAL LOAD MANAGEMENT FOR THE CALIFORNIA WATER SYSTEM  

E-Print Network (OSTI)

dam and the Thermalito pumped storage units in the north,This generation pumped storage, and recovery generation, (electricity demand. In a pumped-storage system, water is

Krieg, B.

2010-01-01T23:59:59.000Z

350

Partnership with Industries- A Successful "Conservation and Load Management Program"  

E-Print Network (OSTI)

Carolina power and light provides electric service to about 3 million people in the rapidly growing sun belt area of some 30,000 square miles in eastern North and South Carolina; almost half of North Carolina and one-fourth of South Carolina. Most customers live in uncongested small towns and active urban centers largely in the coastal plains, although the company also serves portions of the piedmont and mountain sections of the two states. CP&L's service area is attractive for its diversity of climate, geography, and, excellent economic perspective. The geographic area is outlined below.

Johnston, W. E.

1985-05-01T23:59:59.000Z

351

Plan-based policies for efficient multiple battery load management  

Science Conference Proceedings (OSTI)

Efficient use of multiple batteries is a practical problem with wide and growing application. The problem can be cast as a planning problem under uncertainty. We describe the approach we have adopted to modelling and solving this problem, seen as a Markov ...

Maria Fox; Derek Long; Daniele Magazzeni

2012-05-01T23:59:59.000Z

352

Smart Building Solutions for Plug-Load Management, Sensing and...  

NLE Websites -- All DOE Office Websites (Extended Search)

and control on a outlet-per-outlet basis. Visible Energy products presented are the "UFO Power Strip", a four-socket smart power-strip, and the single socket, corded...

353

Active coordination of thermal household appliances for load management purposes  

E-Print Network (OSTI)

Copyright notice: ©2009 IFAC. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works

Stephan Koch; Marek Zima; Göran Andersson

2009-01-01T23:59:59.000Z

354

Hanford Contractor Receives Awards for Safety | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Contractor Receives Awards for Safety Contractor Receives Awards for Safety Hanford Contractor Receives Awards for Safety September 30, 2013 - 12:00pm Addthis RICHLAND, Wash. - A Hanford site contractor supporting EM's cleanup program has again received a prestigious safety award from DOE's Voluntary Protection Program (VPP). Advanced Technologies and Laboratories International (ATL) was presented the Star of Excellence Award for safety at the 29th annual VPP Participants Association Conference in Nashville, Tenn. Since it became a prime contractor at Hanford in 2005, ATL has received the award twice for committing to the principles of VPP, reaching established safety and health goals and attaining an injury and illness rate well below the average for similar businesses. ATL also received the 2013 Outreach Award alongside other Hanford prime

355

Hanford Contractor Receives Awards for Safety | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Hanford Contractor Receives Awards for Safety Hanford Contractor Receives Awards for Safety Hanford Contractor Receives Awards for Safety September 30, 2013 - 12:00pm Addthis RICHLAND, Wash. - A Hanford site contractor supporting EM's cleanup program has again received a prestigious safety award from DOE's Voluntary Protection Program (VPP). Advanced Technologies and Laboratories International (ATL) was presented the Star of Excellence Award for safety at the 29th annual VPP Participants Association Conference in Nashville, Tenn. Since it became a prime contractor at Hanford in 2005, ATL has received the award twice for committing to the principles of VPP, reaching established safety and health goals and attaining an injury and illness rate well below the average for similar businesses. ATL also received the 2013 Outreach Award alongside other Hanford prime

356

EM's Huizenga Receives Presidential Rank Award | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

EM's Huizenga Receives Presidential Rank Award EM's Huizenga Receives Presidential Rank Award EM's Huizenga Receives Presidential Rank Award May 9, 2013 - 12:00pm Addthis EM Senior Advisor Dave Huizenga, left, receives the Presidential Rank of Distinguished Executive award from Eric Coulter, treasurer of the board of directors for the Senior Executives Association, which sponsors the awards program. EM Senior Advisor Dave Huizenga, left, receives the Presidential Rank of Distinguished Executive award from Eric Coulter, treasurer of the board of directors for the Senior Executives Association, which sponsors the awards program. WASHINGTON, D.C. - EM Senior Advisor Dave Huizenga recently received the nation's highest civil service recognition, the Presidential Rank of Distinguished Executive award. The Senior Executives Association sponsored the annual awards event. In

357

Quantum receivers with squeezing and photon-number-resolving detectors  

E-Print Network (OSTI)

We propose quantum receivers with optical squeezing and photon-number-resolving detector (PNRD) for the near-optimal discrimination of quaternary phase-shift-keyed coherent state signals. The basic scheme is similar to the previous proposals (e.g. Phys. Rev. A 84, 042328 (2012)) in which displacement operations, on-off detectors, and electrical feedforward operations were used. Here we study two types of receivers where one installs optical squeezings and the other uses PNRDs instead of on-off detectors. We show that both receivers can attain lower error rates than that by the previous scheme and in particular, the PNRD based receiver has a significant gain under the fixed number of feedfoward steps. Moreover, we show that the PNRD based receiver can suppress the errors due to dark counts, which is not possible by the on-off detector based receiver with a limited number of feedforwards.

Shuro Izumi; Masahiro Takeoka; Kazuhiro Ema; Masahide Sasaki

2013-02-12T23:59:59.000Z

358

Radiant energy receiver having improved coolant flow control means  

DOE Patents (OSTI)

An improved coolant flow control for use in radiant energy receivers of the type having parallel flow paths is disclosed. A coolant performs as a temperature dependent valve means, increasing flow in the warmer flow paths of the receiver, and impeding flow in the cooler paths of the receiver. The coolant has a negative temperature coefficient of viscosity which is high enough such that only an insignificant flow through the receiver is experienced at the minimum operating temperature of the receiver, and such that a maximum flow is experienced at the maximum operating temperature of the receiver. The valving is accomplished by changes in viscosity of the coolant in response to the coolant being heated and cooled. No remotely operated valves, comparators or the like are needed.

Hinterberger, H.

1980-10-29T23:59:59.000Z

359

EM's Huizenga Receives Presidential Rank Award | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Huizenga Receives Presidential Rank Award Huizenga Receives Presidential Rank Award EM's Huizenga Receives Presidential Rank Award May 9, 2013 - 12:00pm Addthis EM Senior Advisor Dave Huizenga, left, receives the Presidential Rank of Distinguished Executive award from Eric Coulter, treasurer of the board of directors for the Senior Executives Association, which sponsors the awards program. EM Senior Advisor Dave Huizenga, left, receives the Presidential Rank of Distinguished Executive award from Eric Coulter, treasurer of the board of directors for the Senior Executives Association, which sponsors the awards program. WASHINGTON, D.C. - EM Senior Advisor Dave Huizenga recently received the nation's highest civil service recognition, the Presidential Rank of Distinguished Executive award. The Senior Executives Association sponsored the annual awards event. In

360

Load transfer coupling regression curve fitting for distribution load forecasting  

SciTech Connect

The planning of distribution facilities requires forecasts of future substation and feeder loads. Extrapolation based on a curve fit to past annual peak loads is currently the most popular manner of accomplishing this forecast. Curve fitting suffers badly from data shifts caused by switching as loads are routinely moved from one substation to another during the course of utility operations. This switching contaminates the data, reducing forecast accuracy. A new regression application reduces error due to these transfers by over an order of magnitude. A key to the usefulness of this method is that the amount of the transfer, and its direction (whether it was to or from a substation), is not a required input. The new technique, aspects of computer implementation of it, and a series of tests showing its advantage over normal multiple regression methods are given.

Willis, H.L.; Powell, R.W.

1984-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "load management receiver" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

A model of the domestic hot water load  

SciTech Connect

The electrical load required to supply domestic hot water is an important load for two reasons: (1) It represents a large portion (30 to 50%) of the domestic load; (2) It is a load which can easily be controlled by the consumer or the supplier, because the use of the hot water need not coincide with the heating of hot water. A model representing the electrical system load due to hot water consumption from storage water heaters is provided. Variable parameters include the average amount of water used, the mean and deviation of distributions of usage times, thermostat settings, inlet water temperature and electrical heating element ratings. These parameters are used to estimate the after diversity electricity demand profile, and were verified for accuracy by comparison with measurements. The model enables this prediction of the effects of load control, examples of which are given in this paper. The model is also useful for evaluation of the response which could be expected from demand-side management options. These include changing the size of heating elements, reduction in water consumption and reduction in thermostat settings.

Lane, I.E. [Energy Efficiency Enterprises, Lynnwood Manor (South Africa); Beute, N. [Cape Technikon, Cape Town (South Africa)

1996-11-01T23:59:59.000Z

362

Wind loading on solar concentrators: some general considerations  

DOE Green Energy (OSTI)

A survey has been completed to examine the problems and complications arising from wind loading on solar concentrators. Wind loading is site specific and has an important bearing on the design, cost, performance, operation and maintenance, safety, survival, and replacement of solar collecting systems. Emphasis herein is on paraboloidal, two-axis tracking systems. Thermal receiver problems also are discussed. Wind characteristics are discussed from a general point of view; current methods for determining design wind speed are reviewed. Aerodynamic coefficients are defined and illustrative examples are presented. Wind tunnel testing is discussed, and environmental wind tunnels are reviewed; recent results on heliostat arrays are reviewed as well. Aeroelasticity in relation to structural design is discussed briefly. Wind loads, i.e., forces and moments, are proportional to the square of the mean wind velocity. Forces are proportional to the square of concentrator diameter, and moments are proportional to the cube of diameter. Thus, wind loads have an important bearing on size selection from both cost and performance standpoints. It is concluded that sufficient information exists so that reasonably accurate predictions of wind loading are possible for a given paraboloidal concentrator configuration, provided that reliable and relevant wind conditions are specified. Such predictions will be useful to the design engineer and to the systems engineer as well. Information is lacking, however, on wind effects in field arrays of paraboloidal concentrators. Wind tunnel tests have been performed on model heliostat arrays, but there are important aerodynamic differences between heliostats and paraboloidal dishes.

Roschke, E. J.

1984-05-01T23:59:59.000Z

363

Receiver for solar-energy collector having improved aperture aspect  

DOE Patents (OSTI)

A secondary concentrator for use in receiver systems for linear focusing primary concentrators is provided with reflector wings at each end. The wings increase the capture of light rays reflected from areas adjacent the rim of a primary concentrator, increasing the apparent aperture size of the receiver as viewed from the rim of the primary concentrator. The length, tilt, and curvature of the wing reflectors can be adjusted to provide a receiver having a desired aperture aspect.

McIntire, W.R.

1981-03-13T23:59:59.000Z

364

FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH  

E-Print Network (OSTI)

PSLF that incorporates motor  A?C, ZIP, and electronic load the fractions motors A?C, ZIP, and electronic loads.    Usethat incorporates motor  A?C, ZIP, and  electronic load 

Lesieutre, Bernard

2013-01-01T23:59:59.000Z

365

load profile | OpenEI Community  

Open Energy Info (EERE)

load profile Home Sfomail's picture Submitted by Sfomail(48) Member 17 May, 2013 - 13:03 Commercial and Residential Hourly Load Data Now Available on OpenEI building load building...

366

Monthly Crustal Loading Corrections for Satellite Altimetry  

Science Conference Proceedings (OSTI)

Satellite altimeter measurements of sea surface height include a small contribution from vertical motion of the seafloor caused by crustal loading. Loading by ocean tides is routinely allowed for in altimeter data processing. Here, loading by ...

R. D. Ray; S. B. Luthcke; T. van Dam

2013-05-01T23:59:59.000Z

367

Interference mitigation techniques for SAW-less CDMA receivers  

E-Print Network (OSTI)

fre- quency division duplexed (FDD) receivers. In the ?rstfrequency-division duplexed (FDD), i.e. , the mobile stationfrequency-division duplexed (FDD) wireless communication

Khatri, Himanshu

2009-01-01T23:59:59.000Z

368

Highly linear SAW-less receiver design techniques for CDMA  

E-Print Network (OSTI)

frequency divi- sion duplexed (FDD) receivers, so that thefor frequency division duplex (FDD) systems [9,28], and thethe leaked Tx signal in FDD system prevent SAW- less

Kim, Nam Soo

2010-01-01T23:59:59.000Z

369

Alaska Native Communities Receive Technical Assistance for Local...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

will receive assistance with prioritizing renewable energy projects, evaluating feasibility studies, fostering community support, and identifying next steps to move projects...

370

LED North America Receives Exclusive Patent License for ORNL...  

NLE Websites -- All DOE Office Websites (Extended Search)

Highlights Success Stories Contact Us Index Home | ORNL | Success Stories SHARE LED North America Receives Exclusive Patent License for ORNL Technology June 19, 2013 Views...

371

DOE Lab Receives Award for Work on Drilling Technology | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

recognized as an innovator in this area is an honor. The Department of Energy's National Energy Technology Laboratory (NETL) recently received that honor when it was recognized...

372

Collector/Receiver Characterization (Fact Sheet), Thermal Systems...  

NLE Websites -- All DOE Office Websites (Extended Search)

radiation falling on the trough aperture operating near ambient temperature to the thermal energy collected by the fluid flowing through the receiver tube. A parabolic trough,...

373

Five companies received funding through new venture acceleration...  

NLE Websites -- All DOE Office Websites (Extended Search)

proposals and those receiving funding included: San Ildefonso Development Corp., Three Eagles Development Corp., Cochitit Pueblo Development Corp., Sunbeam Indian Art and Avanyu...

374

Alaska Native Communities Receive Technical Assistance for Local...  

NLE Websites -- All DOE Office Websites (Extended Search)

Articles Alaska Native Tribes Receive Technical Assistance for Local Clean Energy Projects DOE Office of Indian Energy Partners with ACEP to Study Wind-Diesel Systems in Alaska...

375

Alaska Native Tribes Receive Technical Assistance for Local Clean...  

NLE Websites -- All DOE Office Websites (Extended Search)

of Kake will receive assistance to help develop a community energy plan; relocating a wind met-tower closer to the village; conduct biomass and hydro generation feasibility...

376

Charles "Chuck" Farrar to receive DeMichele Award  

NLE Websites -- All DOE Office Websites (Extended Search)

Institute, will receive the 2013 DeMichele Award from the Society for Experimental Mechanics. The award is presented for demonstrated "exemplary service and support of promoting...

377

NNSA National Security Campus Receives LEED® Gold Certification...  

NLE Websites -- All DOE Office Websites (Extended Search)

Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > Media Room > Press Releases > NNSA National Security Campus Receives LEED Gold...

378

Secretary Chu Announces 150 Students to Receive Graduate Fellowships...  

NLE Websites -- All DOE Office Websites (Extended Search)

Secretary Chu Announces 150 Students to Receive Graduate Fellowships in Science, Mathematics and Engineering New Department of Energy Graduate Fellowship Program Aimed at...

379

DOE Receives Responses on the Implementation of Large-Capacity...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

units. We received responses from several parties, which can be found below. Alliance Laundry Systems EarthJustice Electrolux GE Appliances and Lighting LG Electronics Whirlpool...

380

Support and maneuvering apparatus for solar energy receivers  

DOE Patents (OSTI)

A support and maneuvering apparatus is disclosed for a solar energy receiving device adpated for receiving and concentrating solar energy and having a central axis extending through the center thereof. The apparatus includes a frame for mounting the perimeter of said solar energy receiving device. A support member extends along the central axis of the receiving device and has a base end passing through the center of the receiving device and an outer distal end adapted for carrying a solar energy receiving and conversion mechanism. A variable tension mechanism interconnects the support member with the frame to provide stiffening for the support member and the frame and to assist in the alignment of the frame to optimize the optical efficiency of the solar energy receiving device. A rotatable base is provided, and connecting members extend from the base for pivotable attachment to the frame at spaced positions therealong. Finally, an elevation assembly is connected to the receiving device for selectively pivoting the receiving device about an axis defined between the attachment positions of the connecting members on the frame.

Murphy, Lawrence M. (Littleton, CO)

1989-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "load management receiver" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Support and maneuvering apparatus for solar energy receivers  

DOE Patents (OSTI)

A support and maneuvering apparatus is disclosed for a solar energy receiving device adapted for receiving and concentrating solar energy and having a central axis extending through the center thereof. The apparatus includes a frame for mounting the perimeter of said solar energy receiving device. A support member extends along the central axis of the receiving device and has a base end passing through the center of the receiving device and an outer distal end adapted for carrying a solar energy receiving and conversion mechanism. A variable tension mechanism interconnects the support member with the frame to provide stiffening for the support member and the frame and to assist in the alignment of the frame to optimize the optical efficiency of the solar energy receiving device. A rotatable base is provided, and connecting members extend from the base for pivotable attachment to the frame at spaced positions therealong. Finally, an elevation assembly is connected to the receiving device for selectively pivoting the receiving about an axis defined between the attachment positions of the connecting members on the frame. 4 figs.

Murphy, L.M.

1988-07-28T23:59:59.000Z

382

SunShot Initiative: High-Flux Microchannel Solar Receiver  

NLE Websites -- All DOE Office Websites (Extended Search)

(CSP) R&D funding opportunity announcement (FOA), are working to develop an advanced heat exchanger for use in CSP receivers. The heat exchanger has the potential to...

383

Solar Radio Burst Effects on Global Positioning System Receivers .  

E-Print Network (OSTI)

??This thesis presents a series of studies investigating solar radio burst effects on Global Positioning System (GPS) receivers along with supporting instrumentation and analysis techniques.… (more)

Cerruti, Alessandro Paolo

2007-01-01T23:59:59.000Z

384

NETL'S CHORPENING RECEIVES 2012 EXCELLENCE IN GOVERNMENT AWARD  

NLE Websites -- All DOE Office Websites (Extended Search)

CHORPENING RECEIVES 2012 EXCELLENCE IN GOVERNMENT AWARD Morgantown, W.Va. - The National Energy Technology Laboratory's (NETL) Ben Chorpening has been selected by the Pittsburgh...

385

NETL'S WOODRUFF RECEIVES 2012 EXCELLENCE IN GOVERNMENT AWARD  

NLE Websites -- All DOE Office Websites (Extended Search)

WOODRUFF RECEIVES 2012 EXCELLENCE IN GOVERNMENT AWARD Morgantown, W.Va. - The National Energy Technology Laboratory's (NETL) Dr. Steven D. Woodruff has been selected by the...

386

NETL'S LYONS RECEIVES 2012 EXCELLENCE IN GOVERNMENT AWARD  

NLE Websites -- All DOE Office Websites (Extended Search)

LYONS RECEIVES 2012 EXCELLENCE IN GOVERNMENT AWARD Morgantown, W.Va. - The National Energy Technology Laboratory's (NETL) David Lyons has been selected by the Pittsburgh...

387

NETL'S GOLLAKOTA RECEIVES 2012 EXCELLENCE IN GOVERNMENT AWARD  

NLE Websites -- All DOE Office Websites (Extended Search)

GOLLAKOTA RECEIVES 2012 EXCELLENCE IN GOVERNMENT AWARD Morgantown, W.Va. - The National Energy Technology Laboratory's (NETL) Dr. Sai Gollakota has been selected by the...

388

NETL's Ohodnicki Receives 2012 Excellence in Government Award  

NLE Websites -- All DOE Office Websites (Extended Search)

Ohodnicki Receives 2012 Excellence in Government Award Pittsburgh, Pa. - The National Energy Technology Laboratory's (NETL) Paul R. Ohodnicki, Jr., has been selected by the...

389

Reproductive Goals and Behavior Among Teen Mothers Receiving AFDC  

E-Print Network (OSTI)

GOALS AND BEHAVIORS AMONG TEEN MOTHERS RECEIVING AFDC ReportSubmitted AFDC Policy to: Brandl Services Implementationnot living No boyfnend status: AFDC Program Currently on

Mauldon, Jane; Maestas, Nicole

1999-01-01T23:59:59.000Z

390

Four Argonne National Laboratory scientists receive Early Career...  

NLE Websites -- All DOE Office Websites (Extended Search)

Four Argonne National Laboratory scientists receive Early Career Research Program awards By Brian Grabowski * May 10, 2012 Tweet EmailPrint ARGONNE, Ill. - Four researchers at the...

391

Argonne fast-reactor pioneer receives international prize  

NLE Websites -- All DOE Office Websites (Extended Search)

Argonne fast-reactor pioneer receives international prize Director's Welcome Organization Achievements Highlights Fact Sheets, Brochures & Other Documents Multimedia Library About...

392

Field Survey of Parabolic Trough Receiver Thermal Performance: Preprint  

SciTech Connect

This paper describes a technique that uses an infrared camera to evaluate the in-situ thermal performance of parabolic trough receivers at operating solar power plants.

Price, H.; Forristall, R.; Wendelin, T.; Lewandowski, A.; Moss, T.; Gummo, C.

2006-04-01T23:59:59.000Z

393

Window and seal design for a small particle solar receiver.  

E-Print Network (OSTI)

??Central receivers for solar power towers have recently been under intense investigation. They can convert solar radiation into electricity by supplying heat to a thermodynamic… (more)

Mande, Onkar Kiran

2012-01-01T23:59:59.000Z

394

Analysis and design of CMOS ultra wideband receivers  

E-Print Network (OSTI)

robust operation of the receiver in dense wireless networks.satisfactory operation of the UWB system in dense wirelesswireless environments. The successful and robust operation

Ranjan, Mahim

2006-01-01T23:59:59.000Z

395

Sandia National Laboratories: Sandia Receives Award for Electronics...  

NLE Websites -- All DOE Office Websites (Extended Search)

Laboratories has received an award for reducing the environmental impacts of the computers, printers and other office electronics it uses through its fiscal year 2010...

396

Sixty-five New Mexico students receive Los Alamos Employees'...  

NLE Websites -- All DOE Office Websites (Extended Search)

2 May Los Alamos Employees' Scholarship Fund recipients Sixty-five New Mexico students receive Los Alamos Employees' Scholarship Fund scholarships Los Alamos High School...

397

Seventy-three New Mexico students receive Los Alamos Employees...  

NLE Websites -- All DOE Office Websites (Extended Search)

Employees' Scholarship Fund Seventy-three New Mexico students receive Los Alamos Employees' Scholarship Fund scholarships Kevin Gao, Micaela Lucero and Danielle Harrier share this...

398

Fifty-five New Mexico students receive Los Alamos Employees'...  

NLE Websites -- All DOE Office Websites (Extended Search)

Employees' Scholarship Fund scholarships Fifty-five New Mexico students receive Los Alamos Employees' Scholarship Fund scholarships Escalante High School senior Estevan Trujillo is...

399

Building Energy Software Tools Directory: Load Express  

NLE Websites -- All DOE Office Websites (Extended Search)

graphical interface makes Load Express a powerful engineering tool with a very short learning curve. The "rookie" or experienced user can quickly and accurately perform load...

400

Self-aligning biaxial load frame  

DOE Patents (OSTI)

An self-aligning biaxial loading apparatus for use in testing the strength of specimens while maintaining a constant specimen centroid during the loading operation. The self-aligning biaxial loading apparatus consists of a load frame and two load assemblies for imparting two independent perpendicular forces upon a test specimen. The constant test specimen centroid is maintained by providing elements for linear motion of the load frame relative to a fixed cross head, and by alignment and linear motion elements of one load assembly relative to the load frame. 3 figures.

Ward, M.B.; Epstein, J.S.; Lloyd, W.R.

1994-01-18T23:59:59.000Z

Note: This page contains sample records for the topic "load management receiver" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Learning to be energy-wise: discriminative methods for load disaggregation  

Science Conference Proceedings (OSTI)

In this paper we describe an ongoing project which develops an automated residential Demand Response (DR) system that attempts to manage residential loads in accordance with DR signals. In this early stage of the project, we propose an approach for identifying ... Keywords: context-awareness, data mining, energy management, non-intrusive, ubiquitous computing

Dwi Rahayu; Balakrishnan Narayanaswamy; Shonali Krishnaswamy; Cyril Labbé; Deva P. Seetharam

2012-05-01T23:59:59.000Z

402

ELECTRICAL LOAD ANTICIPATOR AND RECORDER  

DOE Patents (OSTI)

A system is described in which an indication of the prevailing energy consumption in an electrical power metering system and a projected power demand for one demand in terval is provided at selected increments of time within the demand interval. Each watt-hour meter in the system is provided with an impulse generator that generates two impulses for each revolution of the meter disc. In each demand interval, for example, one half-hour, of the metering system, the total impulses received from all of the meters are continuously totaled for each 5-minute interval and multiplied by a number from 6 to 1 depending upon which 5- minute interval the impulses were received. This value is added to the total pulses received in the intervals preceding the current 5-minute interval within the half-hour demand interval tc thereby provide an indication of the projected power demand every 5 minutes in the demand interval.

Werme, J.E.

1961-09-01T23:59:59.000Z

403

Method for loading resin beds  

DOE Patents (OSTI)

An improved method of preparing nuclear reactor fuel by carbonizing a uranium loaded cation exchange resin provided by contacting a H.sup.+ loaded resin with a uranyl nitrate solution deficient in nitrate, comprises providing the nitrate deficient solution by a method comprising the steps of reacting in a reaction zone maintained between about 145.degree.-200.degree. C, a first aqueous component comprising a uranyl nitrate solution having a boiling point of at least 145.degree. C with a second aqueous component to provide a gaseous phase containing HNO.sub.3 and a reaction product comprising an aqueous uranyl nitrate solution deficient in nitrate.

Notz, Karl J. (Oak Ridge, TN); Rainey, Robert H. (Knoxville, TN); Greene, Charles W. (Knoxville, TN); Shockley, William E. (Oak Ridge, TN)

1978-01-01T23:59:59.000Z

404

Direct versus Facility Centric Load Control for Automated Demand Response  

SciTech Connect

Direct load control (DLC) refers to the scenario where third party entities outside the home or facility are responsible for deciding how and when specific customer loads will be controlled in response to Demand Response (DR) events on the electric grid. Examples of third parties responsible for performing DLC may be Utilities, Independent System Operators (ISO), Aggregators, or third party control companies. DLC can be contrasted with facility centric load control (FCLC) where the decisions for how loads are controlled are made entirely within the facility or enterprise control systems. In FCLC the facility owner has more freedom of choice in how to respond to DR events on the grid. Both approaches are in use today in automation of DR and both will continue to be used in future market segments including industrial, commercial and residential facilities. This paper will present a framework which can be used to differentiate between DLC and FCLC based upon where decisions are made on how specific loads are controlled in response to DR events. This differentiation is then used to compare and contrast the differences between DLC and FCLC to identify the impact each has on:(1)Utility/ISO and third party systems for managing demand response, (2)Facility systems for implementing load control, (3)Communications networks for interacting with the facility and (4)Facility operators and managers. Finally a survey of some of the existing DR related specifications and communications standards is given and their applicability to DLC or FCLC. In general FCLC adds more cost and responsibilities to the facilities whereas DLC represents higher costs and complexity for the Utility/ISO. This difference is primarily due to where the DR Logic is implemented and the consequences that creates. DLC may be more certain than FCLC because it is more predictable - however as more loads have the capability to respond to DR signals, people may prefer to have their own control of end-use loads and FCLC systems. Research is needed to understand the predictability of FCLC which is related to the perceived value of the DR from the facility manager or home owner's perspective.

Koch, Ed; Piette, Mary Ann

2009-11-06T23:59:59.000Z

405

Transportation and Program Management Services  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Atlanta, Georgia Atlanta, Georgia Transportation and Program Management Services Secured Transportation Services, LLC Founded: December, 2003 ff Staff: 7 Experience: Over 145 years combined experience in Nuclear Transportation, Security, HP & Operations Services Transportation The largest Transportation Coordinators of Spent Nuclear Fuel in North America On-Site, Hands-On Assistance (Before & During both Loading & Transport) P d A i t (W iti d/ R i ) Procedure Assistance (Writing and/or Review) Package Handling, Loading Services Certificate of Compliance and Competent Authority Reviews & Requests Carrier Coordination (Empty Packages & Equipment, Loaded, & Returns) Vessel Charters, Special Trains, Dedicated Exclusive Use Trucks p

406

Publications Received Books listed below that are marked with a  

E-Print Network (OSTI)

: CSL1 Publications (Stanford monographs in linguistics), 2001, viii+255 pp; distributedPublications Received Books listed below that are marked with a t have been selected for review. All rel- evant books received will be listed, but not all can be reviewed. Technical reports (other

407

Publications Received Books listed below that are marked with a  

E-Print Network (OSTI)

, volume 1 Harry Bunt and Reinhard Muskens (editors) (Tilburg University) Dordrecht: Kluwer Academic 468 #12;Publications Received Meijs, volume 30), 2000, xv+344 pp; hardbound, ISBN 90-420-0419-3, $97Publications Received Books listed below that are marked with a t have been selected for review

408

Compound parabolic concentrators for narrowband wireless infrared receivers  

E-Print Network (OSTI)

Compound parabolic concentrators for narrowband wireless infrared receivers Keang-Po Ho Joseph M and hollow compound parabolic concentrators (CPCs), for use in free-space infrared communication receivers terms: compound parabolic concentrators (CPCs); optical bandpass fil- ters; Monte Carlo ray tracing

Kahn, Joseph M.

409

Numerical modeling of dish-Stirling reflux solar receivers  

DOE Green Energy (OSTI)

Using reflux solar receivers to collect solar energy for dish-Stirling electric power generation systems is currently being investigated by several organizations, including Sandia National Laboratories, Albuquerque, New Mexico. In support of this program, Sandia has developed two numerical models describing the energy transfer within and thermal performance of pool-boiler and heat-pipe receivers. Both models are applicable to axisymmetric geometries and they both consider the radiative and convective energy transfer within the receiver cavity, the conductive and convective energy transfer within the receiver cavity, the conductive and convective energy transfer from the receiver housing, and the energy transfer to the receiver working fluid. In these models, the radiative transfer within the receiver is analyzed using a two-band (solar and infrared) net-radiation formulation for enclosure radiation. Empirical convective correlations describe the convective heat transfer from the cavity to the surroundings. The primary difference between the models is the level of detail in modeling the heat conduction through the receiver walls. The more detailed model uses a two-dimensional finite control volume method, whereas the simpler model uses a one-dimensional thermal resistance approach. 20 refs., 7 figs., 2 tabs.

Hogan, R.E.

1990-01-01T23:59:59.000Z

410

High-temperature seal development for the share receiver  

DOE Green Energy (OSTI)

The development and experimental demonstration of a high-temperature seal for the SHARE ceramic dome cavity receiver is reported. The mechanical contact seal which was tested on one-foot diameter silicon carbide ceramic dome hardware at pressure differentials to four atmospheres and dome temperatures to 2200/sup 0/F (1200/sup 0/C) showed negligible leakage at expected receiver operating conditions.

Jarvinen, P. O.

1979-01-01T23:59:59.000Z

411

Load Reduction, Demand Response and Energy Efficient Technologies and Strategies  

SciTech Connect

The Department of Energy’s (DOE’s) Pacific Northwest National Laboratory (PNNL) was tasked by the DOE Office of Electricity (OE) to recommend load reduction and grid integration strategies, and identify additional demand response (energy efficiency/conservation opportunities) and strategies at the Forest City Housing (FCH) redevelopment at Pearl Harbor and the Marine Corps Base Hawaii (MCBH) at Kaneohe Bay. The goal was to provide FCH staff a path forward to manage their electricity load and thus reduce costs at these FCH family housing developments. The initial focus of the work was at the MCBH given the MCBH has a demand-ratchet tariff, relatively high demand (~18 MW) and a commensurate high blended electricity rate (26 cents/kWh). The peak demand for MCBH occurs in July-August. And, on average, family housing at MCBH contributes ~36% to the MCBH total energy consumption. Thus, a significant load reduction in family housing can have a considerable impact on the overall site load. Based on a site visit to the MCBH and meetings with MCBH installation, FCH, and Hawaiian Electric Company (HECO) staff, recommended actions (including a "smart grid" recommendation) that can be undertaken by FCH to manage and reduce peak-demand in family housing are made. Recommendations are also made to reduce overall energy consumption, and thus reduce demand in FCH family housing.

Boyd, Paul A.; Parker, Graham B.; Hatley, Darrel D.

2008-11-19T23:59:59.000Z

412

Energy Department Receives EPA Award for Top Green Power Purchase |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Department Receives EPA Award for Top Green Power Purchase Energy Department Receives EPA Award for Top Green Power Purchase Energy Department Receives EPA Award for Top Green Power Purchase September 24, 2013 - 12:19pm Addthis The Energy Department announced today that it has received a 2013 Green Power Leadership Award from the U.S. Environmental Protection Agency (EPA). The annual awards recognize the country's leading green power consumers for their commitment and contribution to helping advance the development of the nation's voluntary green power market. EPA presented the Energy Department with the award at an event held in conjunction with the 2013 Renewable Energy Markets Conference in Austin, Texas, on September 23, 2013. The Department was one of only eight organizations nationwide to receive a Leadership Award for utilization of green power. The award recognizes EPA

413

Energy Department Receives EPA Award for Top Green Power Purchase |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Department Receives EPA Award for Top Green Power Purchase Energy Department Receives EPA Award for Top Green Power Purchase Energy Department Receives EPA Award for Top Green Power Purchase September 24, 2013 - 12:19pm Addthis The Energy Department announced today that it has received a 2013 Green Power Leadership Award from the U.S. Environmental Protection Agency (EPA). The annual awards recognize the country's leading green power consumers for their commitment and contribution to helping advance the development of the nation's voluntary green power market. EPA presented the Energy Department with the award at an event held in conjunction with the 2013 Renewable Energy Markets Conference in Austin, Texas, on September 23, 2013. The Department was one of only eight organizations nationwide to receive a Leadership Award for utilization of green power. The award recognizes EPA

414

Five Pilot Projects Receive Grants to Promote Online Security ...  

Science Conference Proceedings (OSTI)

... Association of Motor Vehicle Administrators (AAMVA ... Department of Motor Vehicles, Biometric Signature ID ... management at General Electric; and first ...

2012-11-06T23:59:59.000Z

415

PRB rail loadings shatter record  

Science Conference Proceedings (OSTI)

Rail transport of coal in the Powder River Basin has expanded, with a record 2,197 trains loaded in a month. Arch Coal's Thunder basin mining complex has expanded by literally bridging the joint line railway. The dry fork mine has also celebrated its safety achievements. 4 photos.

Buchsbaum, L.

2008-09-15T23:59:59.000Z

416

Office of River Protection Women-Owned Small Business Contractor Receives  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

River Protection Women-Owned Small Business Contractor River Protection Women-Owned Small Business Contractor Receives One-Year Extension Office of River Protection Women-Owned Small Business Contractor Receives One-Year Extension December 19, 2012 - 10:33am Addthis Richland - - The Energy Department's Office of River Protection announced the contract for Advanced Technologies and Laboratories International Inc. (ATL) has been extended for a second one-year option. ATL, a women-owned small business, will continue to provide analytical services and testing work at the Hanford Site 222-S Laboratory through January 2, 2014. "ORP values ATL's performance and commitment to safety," said Ellen Mattlin, Tank Farm Programs Division Director. "DOE appreciates the technical and management capabilities demonstrated by the ATL workforce."

417

Solar Central Receiver Prototype Heliostat. Volume II. Phase II planning (preliminary)  

DOE Green Energy (OSTI)

A currently planned DOE program will develop and construct a 10 MW/sub e/ Pilot Plant to demonstrate the feasibility and operational characteristics of Solar Central Receiver Power Generation. The field of heliostats is a major element of the Solar Central Receiver Power Generation system. The primary objective of the program described is to establish and verify the manufacturability, performance, durability, and maintenance requirements of the commercial plant heliostat design. End products of the 16 month effort include: (1) design, fabrication, and test of heliostats; (2) preliminary designs of manufacturing, assembly, installation, and maintenance processes for quantity production; (3) detailed design of critical tooling or other special equipment for such processes; (4) refined cost estimates for heliostats and maintenance; and (5) an updated commercial plant heliostat preliminary design. The program management and control system is discussed. (WHK)

None

1978-06-01T23:59:59.000Z

418

Waste Receiving and Processing (WRAP) Facility Final Safety Analysis Report (FSAR)  

Science Conference Proceedings (OSTI)

The Waste Receiving and Processing Facility (WRAP), 2336W Building, on the Hanford Site is designed to receive, confirm, repackage, certify, treat, store, and ship contact-handled transuranic and low-level radioactive waste from past and present U.S. Department of Energy activities. The WRAP facility is comprised of three buildings: 2336W, the main processing facility (also referred to generically as WRAP); 2740W, an administrative support building; and 2620W, a maintenance support building. The support buildings are subject to the normal hazards associated with industrial buildings (no radiological materials are handled) and are not part of this analysis except as they are impacted by operations in the processing building, 2336W. WRAP is designed to provide safer, more efficient methods of handling the waste than currently exist on the Hanford Site and contributes to the achievement of as low as reasonably achievable goals for Hanford Site waste management.

TOMASZEWSKI, T.A.

2000-04-25T23:59:59.000Z

419

On-line load relief control  

SciTech Connect

This paper describes the results of an investigation concerning the on-line prediction and enhancement of load relief. The effects of voltage fluctuation, system voltage profile control and generator voltage adjustment on load relief and load shedding operations during under-frequency transients are studied. The technique promoted in the paper may be used to reduce system spinning reserve or prospective load shedding.

Jovanovic, S.; Fox, B.; Thompson, J.G. (Queen' s Univ. of Belfast (United Kingdom))

1994-11-01T23:59:59.000Z

420

Load Forecasting for Modern Distribution Systems  

Science Conference Proceedings (OSTI)

Load forecasting is a fundamental activity for numerous organizations and activities within a utility, including planning, operations, and control. Transmission and Distribution (T&D) planning and design engineers use the load forecast to determine whether any changes and additions are needed to the electric system to satisfy the anticipated load. Other load forecast users include system operations, financial ...

2013-03-08T23:59:59.000Z

Note: This page contains sample records for the topic "load management receiver" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Load Forecast For use in Resource Adequacy  

E-Print Network (OSTI)

Load Forecast 2019 For use in Resource Adequacy Massoud Jourabchi #12;In today's presentation d l­ Load forecast methodology ­ Drivers of the forecast f i­ Treatment of conservation ­ Incorporating impact of weather ­ Forecast for 2019 #12;Regional Loads (MWA and MW)Regional Loads (MWA and MW

422

Evolving non-intrusive load monitoring  

Science Conference Proceedings (OSTI)

Non-intrusive load monitoring (NILM) identifies used appliances in a total power load according to their individual load characteristics. In this paper we propose an evolutionary optimization algorithm to identify appliances, which are modeled as on/off ... Keywords: NILM, evolution, evolutionary algorithm, knapsack problem, non-intrusive load monitoring

Dominik Egarter; Anita Sobe; Wilfried Elmenreich

2013-04-01T23:59:59.000Z

423

Characterizing Household Plug Loads through Self-Administered Load Research  

Science Conference Proceedings (OSTI)

Household miscellaneous loads, which include consumer electronics, are the fastest growing segment of household energy use in the United States. Although the relative energy intensity of applications such as heating and cooling is declining, the DOEAnnual Energy Outlook forecasts that the intensity of residential miscellaneous end uses will increase substantially by 2030. Studies by TIAX and Ecos Consulting reveal that miscellaneous devices8212smaller devices in terms of energy draw but growing in usage8...

2009-12-09T23:59:59.000Z

424

Short-Term Load Forecasting Error Distributions and Implications for Renewable Integration Studies: Preprint  

DOE Green Energy (OSTI)

Load forecasting in the day-ahead timescale is a critical aspect of power system operations that is used in the unit commitment process. It is also an important factor in renewable energy integration studies, where the combination of load and wind or solar forecasting techniques create the net load uncertainty that must be managed by the economic dispatch process or with suitable reserves. An understanding of that load forecasting errors that may be expected in this process can lead to better decisions about the amount of reserves necessary to compensate errors. In this work, we performed a statistical analysis of the day-ahead (and two-day-ahead) load forecasting errors observed in two independent system operators for a one-year period. Comparisons were made with the normal distribution commonly assumed in power system operation simulations used for renewable power integration studies. Further analysis identified time periods when the load is more likely to be under- or overforecast.

Hodge, B. M.; Lew, D.; Milligan, M.

2013-01-01T23:59:59.000Z

425

Load Scheduling with Profile Information  

E-Print Network (OSTI)

. Within the past five years, many manufactures have added hardware performance counters to their microprocessors to generate profile data cheaply. We show how to use Compaq's DCPI tool to determine load latencies which are at a fine, instruction granularity and use them as fodder for improving instruction scheduling. We validate our heuristic for using DCPI latency data to classify loads as hits and misses against simulation numbers. We map our classification into the Multiflow compiler's intermediate representation, and use a locality sensitive Balanced scheduling algorithm. Our experiments illustrate that our algorithm improves run times by 1% on average, but up to 10% on a Compaq Alpha. 1 Introduction This paper explores how to use hardware performance counters to produce fine grain latency information to improve compiler scheduling. We use this information to hide latencies with any available instruction level parallelism (ILP). (ILP for an instruction is the number of o...

Götz Lindenmaier; Kathryn S. McKinley; Olivier Temam

2000-01-01T23:59:59.000Z

426

High-Temperature Falling-Particle Receiver (Fact Sheet)  

Science Conference Proceedings (OSTI)

Sandia National Laboratories is one of the 2012 SunShot CSP R&D awardee for their advanced receivers. This fact sheet explains the motivation, description, and impact of the project.

Not Available

2012-09-01T23:59:59.000Z

427

Advanced Low-Cost Receivers for Parabolic Troughs (Fact Sheet)  

Science Conference Proceedings (OSTI)

Norwich Technologies is one of the 2012 SunShot CSP R&D awardees for their advanced receivers. This fact sheet explains the motivation, description, and impact of the project.

Not Available

2012-09-01T23:59:59.000Z

428

Lab receives an additional $19 million for environmental cleanup  

NLE Websites -- All DOE Office Websites (Extended Search)

Lab receives an additional $19 million for environmental cleanup Lab receives an additional $19 million for environmental cleanup Community Connections: Our link to Northern New Mexico Communities Latest Issue:Dec. 2013 - Jan. 2014 All Issues » submit Lab receives an additional $19 million for environmental cleanup Lab also selects local businesses for five-year contracts June 1, 2013 Governor Susana Martinez visited the Lab in May to urge additional funding for cleanup Governor Susana Martinez visited the Lab in May to urge additional funding for cleanup Contact Editor Linda Anderman Email Community Programs Office Kurt Steinhaus Email Thanks to support from New Mexico Senators Tom Udall and Martin Heinrich, Representatives Ben Ray Lujan and Steve Pearce and Governor Susana Martinez, the Lab has received an additional $19 million for environmental

429

Energy Department Receives Prestigious Closing the Circle Awards for  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Receives Prestigious Closing the Circle Awards Receives Prestigious Closing the Circle Awards for Environmental Stewardship Energy Department Receives Prestigious Closing the Circle Awards for Environmental Stewardship June 13, 2007 - 1:40pm Addthis DOE Won Four Out of Ten Civilian Awards WASHINGTON, DC - The Department of Energy (DOE) this week received four White House Closing the Circle (CTC) awards, which recognize federal leadership in green purchasing, electronics recycling, and energy efficiency practices. These awards are presented annually by the Office of the Federal Environmental Executive for outstanding achievements of Federal employees and their facilities for efforts that make a significant positive impact on environmental stewardship. "I am proud to accept these awards on behalf of all the employees of the

430

Secretary Chu Announces 68 Scientists to Receive Early Career Research  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

68 Scientists to Receive Early Career 68 Scientists to Receive Early Career Research Program Funding Secretary Chu Announces 68 Scientists to Receive Early Career Research Program Funding May 18, 2012 - 3:05pm Addthis News Media Contact (202) 386-4940 WASHINGTON - Underscoring the Obama Administration's commitment to investing in innovation and the American workforce, U.S. Department of Energy Secretary Steven Chu today announced that 68 scientists from across the nation will receive up to $18.9 million in funding for research grants as part of DOE's Early Career Research Program. The effort, now in its third year, is designed to bolster the nation's scientific workforce by providing support to exceptional researchers during the crucial early career years, when many scientists do their most formative work.

431

Energy Department Announces 61 Scientists to Receive Early Career Research  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

61 Scientists to Receive Early Career 61 Scientists to Receive Early Career Research Program Funding Energy Department Announces 61 Scientists to Receive Early Career Research Program Funding May 7, 2013 - 12:56pm Addthis NEWS MEDIA CONTACT (202) 586-4940 WASHINGTON - Underscoring the Obama Administration's commitment to investing in innovation and the American workforce, Acting Secretary of Energy Daniel Poneman today announced that 61 scientists from across the nation will receive up to $15.3 million in funding for research as part of the Energy Department's Early Career Research Program. The effort, now in its fourth year, is designed to bolster the nation's scientific workforce by providing support to exceptional researchers during the crucial early career years, when many scientists do their most formative

432

Los Alamos National Laboratory employees receive Pollution Prevention  

NLE Websites -- All DOE Office Websites (Extended Search)

Employees Receive Pollution Prevention Awards Employees Receive Pollution Prevention Awards Los Alamos National Laboratory employees receive Pollution Prevention Awards Nearly 400 employees on 47 teams received Pollution Prevention awards for protecting the environment and saving taxpayers more than $8 million. April 23, 2013 Molten plutonium in a crucible. The improved processing of old plutonium generates less than half of the waste of the former process. Molten plutonium in a crucible. The improved processing of old plutonium generates less than half of the waste of the former process. Contact Steve Sandoval Communications Office (505) 665-9206 Email The Pollution Prevention Awards are the result of people taking the initiative to improve their own operations. Protecting environment, saving taxpayer dollars

433

Energy Department Receives Prestigious Closing the Circle Awards for  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Department Receives Prestigious Closing the Circle Awards Energy Department Receives Prestigious Closing the Circle Awards for Environmental Stewardship Energy Department Receives Prestigious Closing the Circle Awards for Environmental Stewardship June 13, 2007 - 1:40pm Addthis DOE Won Four Out of Ten Civilian Awards WASHINGTON, DC - The Department of Energy (DOE) this week received four White House Closing the Circle (CTC) awards, which recognize federal leadership in green purchasing, electronics recycling, and energy efficiency practices. These awards are presented annually by the Office of the Federal Environmental Executive for outstanding achievements of Federal employees and their facilities for efforts that make a significant positive impact on environmental stewardship. "I am proud to accept these awards on behalf of all the employees of the

434

Local high school seniors receive Edward Teller science scholarships  

NLE Websites -- All DOE Office Websites (Extended Search)

3 For immediate release: 06052013 | NR-13-06-03 Local high school seniors receive Edward Teller science scholarships Linda A Lucchetti, LLNL, (925) 422-5815, lucchetti1@llnl.gov...

435

Modeling of solar receiver for cracking of liquid petroleum gas  

SciTech Connect

The paper presents the model of an industrial solar receiver/reactor for thermal cracking of liquid petroleum gas (LPG) at the typical temperature range of 800--850 C. The concentrated solar radiation enters the receiver located on the ground and provided with a compound parabolic concentrator (CPC) at the ceiling. This is achieved with a reflecting solar tower. The radiative model uses the classical concept of equivalent gray plane to represent a panel of 40 cracking tubes placed in parallel of a refractory wall of the receiver. The radiative flux distribution on each wall is calculated and the chemistry in each reactor tube is evaluated until convergence is achieved. The design of an industrial size receiver, its behavior, and performance have been evaluated using this model. The computer program based on this model was run for a variety of flow conditions, feed compositions, and pressures.

Segal, A.; Epstein, M. [Weizmann Inst. of Science, Rehovot (Israel). Solar Research Facilities Unit

1997-02-01T23:59:59.000Z

436

Applications Received by DOE/FE to Export Domestically Produced...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Applications Received by DOEFE to Export Domestically Produced LNG from the Lower-48 States (as of August 7, 2013) All Changes Since July 12, 2013 Update Are In Red 1 Company...

437

Applications Received by DOE/FE to Export Domestically Produced...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Applications Received by DOEFE to Export Domestically Produced LNG from the Lower-48 States (as of September 19, 2013) All Changes Since September 11, 2013 Update Are In Red 1...

438

Idaho National Laboratory receives national recognition for Small...  

NLE Websites -- All DOE Office Websites (Extended Search)

DOE-ID Tim Jackson, 208-526-8484 INL Misty Benjamin, 208-526-5940 Idaho National Laboratory receives national recognition for Small Business Mentoring Program IDAHO FALLS The...

439

High-Flux Microchannel Solar Receiver (Fact Sheet)  

Science Conference Proceedings (OSTI)

Oregon State University is one of the 2012 SunShot CSP R&D awardees for their advanced receivers. This fact sheet explains the motivation, description, and impact of the project.

Not Available

2012-09-01T23:59:59.000Z

440

Particle Receiver Integrated with Fluidized Bed (Fact Sheet)  

Science Conference Proceedings (OSTI)

National Renewable Energy Laboratory is one of the 2012 SunShot CSP R&D awardees for their advanced receivers. This fact sheet explains the motivation, description, and impact of the project.

Not Available

2012-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "load management receiver" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

SunShot Initiative: High-Efficiency Receivers for Supercritical...  

NLE Websites -- All DOE Office Websites (Extended Search)

cycle is also being explored. Innovation State-of-the-art solar receivers rely on air or molten salt as the working fluid. However, air has low thermal transfer properties and...

442

Argonne director Isaacs to receive Chicago Council on Science...  

NLE Websites -- All DOE Office Websites (Extended Search)

Argonne director Isaacs to receive Chicago Council on Science and Technology award June 13, 2013 Tweet EmailPrint ARGONNE, Ill. - Eric D. Isaacs, director of the U.S. Department of...

443

Physicist Jim Hammer receives prestigious Edward Teller Award  

NLE Websites -- All DOE Office Websites (Extended Search)

232013 Physicist Jim Hammer receives prestigious Edward Teller Award Breanna Bishop, LLNL, (925) 423-9802, bishop33@llnl.gov High Resolution Image Jim Hammer Jim Hammer, a...

444

LLNL'S Yuan Ping receives DOE Early Career Research Program Award  

NLE Websites -- All DOE Office Websites (Extended Search)

LLNL'S Yuan Ping receives DOE Early Career Research Program Award Breanna Bishop, LLNL, (925) 423-9802, bishop33@llnl.gov Printer-friendly Yuan Ping stands next to the target...

445

Department of Energy Receives Highest Transportation Industry Safety Award  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Receives Highest Transportation Industry Receives Highest Transportation Industry Safety Award Department of Energy Receives Highest Transportation Industry Safety Award May 1, 2007 - 12:45pm Addthis WASHINGTON, DC - The U.S. Department of Energy (DOE) today received the Transportation Community Awareness and Emergency Response (TRANSCAER) Chairman's Award, one of industry's highest transportation safety awards, for helping local communities in emergency preparedness and response. TRANSCAER is a voluntary national organization that assists communities in emergency preparedness and response. "I'm very proud that The Department of Energy has raised the bar for community-based transportation emergency preparedness," Secretary of Energy Samuel W. Bodman said. "Safety is our number one priority, and we will

446

Alaska Native Communities Receive Technical Assistance for Local Clean  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Communities Receive Technical Assistance for Local Communities Receive Technical Assistance for Local Clean Energy Development Alaska Native Communities Receive Technical Assistance for Local Clean Energy Development April 29, 2013 - 3:08pm Addthis News Media Contact (202) 586-4940 WASHINGTON - As part of the Obama Administration's efforts to help Tribal communities across the country enhance their energy security and build a sustainable energy future, the Energy Department and the Denali Commission today announced that five Alaska Native communities will receive technical expertise through the Strategic Technical Assistance Response Team (START) program. Building on five technical assistance awards made last year, the projects selected today will further accelerate local clean energy and energy efficiency projects that advance energy self-sufficiency

447

Pantexan receives Crime Stoppers volunteer award | National Nuclear...  

National Nuclear Security Administration (NNSA)

her dedication last week when she received the Board Member of the Year Award from the Texas Crime Stoppers Council, the first time the honor has gone to a board member from...

448

Performance Management  

Science Conference Proceedings (OSTI)

*. Bookmark and Share. Performance Management. ... If you are unable to access these PDF files, please contact the Office of Workforce Management.

2013-04-20T23:59:59.000Z

449

Hybrid solar central receiver for combined cycle power plant  

DOE Patents (OSTI)

A hybrid combined cycle power plant is described including a solar central receiver for receiving solar radiation and converting it to thermal energy. The power plant includes a molten salt heat transfer medium for transferring the thermal energy to an air heater. The air heater uses the thermal energy to preheat the air from the compressor of the gas cycle. The exhaust gases from the gas cycle are directed to a steam turbine for additional energy production. 1 figure.

Bharathan, D.; Bohn, M.S.; Williams, T.A.

1995-05-23T23:59:59.000Z

450

Hybrid solar central receiver for combined cycle power plant  

DOE Patents (OSTI)

A hybrid combined cycle power plant including a solar central receiver for receiving solar radiation and converting it to thermal energy. The power plant includes a molten salt heat transfer medium for transferring the thermal energy to an air heater. The air heater uses the thermal energy to preheat the air from the compressor of the gas cycle. The exhaust gases from the gas cycle are directed to a steam turbine for additional energy production.

Bharathan, Desikan (Lakewood, CO); Bohn, Mark S. (Golden, CO); Williams, Thomas A. (Arvada, CO)

1995-01-01T23:59:59.000Z

451

PASSIVE DETECTION OF VEHICLE LOADING  

SciTech Connect

The Digital Imaging and Remote Sensing Laboratory (DIRS) at the Rochester Institute of Technology, along with the Savannah River National Laboratory is investigating passive methods to quantify vehicle loading. The research described in this paper investigates multiple vehicle indicators including brake temperature, tire temperature, engine temperature, acceleration and deceleration rates, engine acoustics, suspension response, tire deformation and vibrational response. Our investigation into these variables includes building and implementing a sensing system for data collection as well as multiple full-scale vehicle tests. The sensing system includes; infrared video cameras, triaxial accelerometers, microphones, video cameras and thermocouples. The full scale testing includes both a medium size dump truck and a tractor-trailer truck on closed courses with loads spanning the full range of the vehicle's capacity. Statistical analysis of the collected data is used to determine the effectiveness of each of the indicators for characterizing the weight of a vehicle. The final sensing system will monitor multiple load indicators and combine the results to achieve a more accurate measurement than any of the indicators could provide alone.

Garrett, A.

2012-01-03T23:59:59.000Z

452

Mechanism of Hydrogen Formation in Solar Parabolic Trough Receivers  

SciTech Connect

Solar parabolic trough systems for electricity production are receiving renewed attention, and new solar plants are under construction to help meet the growing demands of the power market in the Western United States. The growing solar trough industry will rely on operating experience it has gained over the last two decades. Recently, researchers found that trough plants that use organic heat transfer fluids (HTF) such as Therminol VP-1 are experiencing significant heat losses in the receiver tubes. The cause has been traced back to the accumulation of excess hydrogen gas in the vacuum annulus that surrounds the steel receiver tube, thus compromising the thermal insulation of the receiver. The hydrogen gas is formed during the thermal decomposition of the organic HTF that circulates inside the receiver loop, and the installation of hydrogen getters inside the annulus has proven to be insufficient for controlling the hydrogen build-up over the lifetime of the receivers. This paper will provide an overview of the chemical literature dealing with the thermal decomposition of diphenyl oxide and biphenyl, the two constituents of Therminol VP-1.

Moens, L.; Blake, D. M.

2008-03-01T23:59:59.000Z

453

Electrical and Production Load Factors  

E-Print Network (OSTI)

Load factors are an important simplification of electrical energy use data and depend on the ratio of average demand to peak demand. Based on operating hours of a facility they serve as an important benchmarking tool for the industrial sector. The operating hours of small and medium sized manufacturing facilities are analyzed to identify the most common operating hour or shift work patterns. About 75% of manufacturing facilities fall into expected operating hour patterns with operating hours near 40, 80, 120 and 168 hours/week. Two types of load factors, electrical and production are computed for each shift classification within major industry categories in the U.S. The load factor based on monthly billing hours (ELF) increases with operating hours from about 0.4 for a nominal one shift operation, to about 0.7 for around-the-clock operation. On the other hand, the load factor based on production hours (PLF) shows an inverse trend, varying from about 1.4 for one shift operation to 0.7 for around-the-clock operation. When used as a diagnostic tool, if the PLF exceeds unity, then unnecessary energy consumption may be taking place. For plants operating at 40 hours per week, the ELF value was found to greater than the theoretical maximum, while the PLF value was greater than one, suggesting that these facilities may have significant energy usage outside production hours. The data for the PLF however, is more scattered for plants operating less than 80 hours per week, indicating that grouping PLF data based on operating hours may not be a reasonable approach to benchmarking energy use in industries. This analysis uses annual electricity consumption and demand along with operating hour data of manufacturing plants available in the U.S. Department of Energy’s Industrial Assessment Center (IAC) database. The annual values are used because more desirable monthly data are not available. Monthly data are preferred as they capture the load profile of the facility more accurately. The data there come from Industrial Assessment Centers which employ university engineering students, faculty and staff to perform energy assessments for small to medium-sized manufacturing plants. The nation-wide IAC program is sponsored by the U.S. Department of Energy.

Sen, Tapajyoti

2009-12-01T23:59:59.000Z

454

Experience with automatic, dynamic load balancing and adaptive finite element computation  

SciTech Connect

Distributed memory, Massively Parallel (MP), MIMD technology has enabled the development of applications requiring computational resources previously unobtainable. Structural mechanics and fluid dynamics applications, for example, are often solved by finite element methods (FEMs) requiring, millions of degrees of freedom to accurately simulate physical phenomenon. Adaptive methods, which automatically refine or coarsen meshes and vary the order of accuracy of the numerical solution, offer greater robustness and computational efficiency than traditional FEMs by reducing the amount of computation required away from physical structures such as shock waves and boundary layers. On MP computers, FEMs frequently result in distributed processor load imbalances. To overcome load imbalance, many MP FEMs use static load balancing as a preprocessor to the finite element calculation. Adaptive methods complicate the load imbalance problem since the work per element is not uniform across the solution domain and changes as the computation proceeds. Therefore, dynamic load balancing is required to maintain global load balance. We describe a dynamic, fine-grained, element-based data migration system that maintains global load balance and is effective in the presence of changing work loads. Global load balance is achieved by overlapping neighborhoods of processors, where each neighborhood performs local load balancing. The method utilizes an automatic element management system library to which a programmer integrates the application`s computational description. The library`s flexibility supports a large class of finite element and finite difference based applications.

Wheat, S.R. [Sandia National Labs., Albuquerque, NM (United States); Devine, K.D. [Rensselaer Polytechnic Inst., Troy, NY (United States). Dept. of Computer Science; Maccabe, A.B. [New Mexico Univ., Albuquerque, NM (United States). Dept. of Computer Science

1993-10-01T23:59:59.000Z

455

Development and application of the spatially explicit load enrichment calculation tool (select) to determine potential E. coli loads in watersheds  

E-Print Network (OSTI)

According to the USEPA National Section 303(d) List Fact Sheet, bacterial pathogens are the leading cause of water quality impairments in Texas. The automated Spatially Explicit Load Enrichment Calculation Tool (SELECT) uses spatially variable factors such as land use, soil condition, and distance to streams to characterize pathogen sources across a watershed. The results support development of Total Maximum Daily Loads (TMDLs) where bacterial contamination is of concern. SELECT calculates potential E. coli loads by distributing the contributing source populations across suitable habitats, applying a fecal production rate, and then aggregating the potential load to the subwatersheds. SELECT provides a Graphical User Interface (GUI), developed in Visual Basic for Applications (VBA) within ArcGIS 9.X, where project parameters can be adjusted for various pollutant loading scenarios. A new approach for characterizing E. coli loads resulting from on-site wastewater treatment systems (OWTSs) was incorporated into the SELECT methodology. The pollutant connectivity factor (PCF) module was created to identify areas potentially contributing E. coli loads to waterbodies during runoff events by weighting the influence of potential loading, runoff potential, and travel distance. Simulation results indicate livestock and wildlife are potentially contributing large amounts of E. coli in the Lake Granbury Watershed in areas where these contributing sources are not currently monitored for E. coli. The bacterial water quality violations near Lake Granbury are most likely the result of malfunctioning OWTSs and pet waste in the runoff. The automated SELECT was verified by characterizing the potential E. coli loading in the Plum Creek Watershed and comparing to results from a prior study (Teague, 2007). The E. coli potential load for the watershed was lower than the previous study due to major differences in assumptions. Comparing the average ranked PCF estimated by physical properties of the watershed with the statistical clustering of watershed characteristics provided similar groupings. SELECT supports the need to evaluate each contributing source separately to effectively allocate site specific best management practices (BMPs). This approach can be used as a screening step for determining areas where detailed investigation is merited. SELECT in conjunction with PCF and clustering analysis can assist decision makers develop Watershed Protection Plans (WPPs) and determine TMDLs.

Riebschleager, Kendra Jean

2008-08-01T23:59:59.000Z

456

What determines the price received by farmers? The case of cocoa in Cameroon  

E-Print Network (OSTI)

2009) What determines the price received by farmers? TheBerkeley. What determines the price received by farmers? Thetheir impact on the prices received by the producers.

Bergaly Kamdem, Cyrille; Galtier, Franck; Gockowski, James; David-Benz, Hélène; Egg, Johny; Kamgnia Dia, Bernadette

2009-01-01T23:59:59.000Z

457

Environmental information management plan  

Science Conference Proceedings (OSTI)

The Environmental Information Management Plan provides an overview of the management of environmental information generation by Hanford Site programs. The long-term nature of environmental programs requires that electronic data, documents, and other materials be kept for extended periods in a secure, controlled, and retrievable manner. An important part of the program is the maintenance of administrative records under the Hanford Federal Facility Agreement and Consent Order (Ecology et al. 1989). The Environmental Information Management Plan introduces Westinghouse Hanford records management and engineering document control systems and their relationship to environmental programs. Specific information is provided about the operation of the Environmental Data Management Center, a central facility that receives, processes, and maintains information related to environmental program activities. The Environmental Data Management Center maintains a reference file, coordinates administrative record activities, and distributes administrative record indexes and administrative record documents to the US Environmental Protection Agency, the US Department of Energy, the Washington State Department of Ecology, and four information repositories. 43 refs., 16 figs., 5 tabs.

Michael, L.E.; Main, G.C.; See, E.J.

1990-03-01T23:59:59.000Z

458

ORISE receives continued recognition at the Star level in DOE...  

NLE Websites -- All DOE Office Websites (Extended Search)

management because of the type and complexity of DOE facilities. Similar to Occupational Safety and Health Administration's program, DOE-VPP provides several proven...

459

DOE Announces First Companies to Receive Industrial Energy Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

will be well positioned to provide a transparent, globally accepted system for validating energy intensity performance improvement and management practices. Consistent with this...

460

Pantex receives eight NNSA DP awards | National Nuclear Security...  

NLE Websites -- All DOE Office Websites (Extended Search)

NNSA DP awards | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing...

Note: This page contains sample records for the topic "load management receiver" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Pantex receives United Way leadership award | National Nuclear...  

National Nuclear Security Administration (NNSA)

United Way leadership award | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response...

462

Neutron Sciences Staff Receive 2012 ORNL Awards Night Honors...  

NLE Websites -- All DOE Office Websites (Extended Search)

and innovation in establishing the foundation for reliability-centered operations and maintenance management at the Spallation Neutron Source and achieving a world-leading...

463

Felt-metal-wick heat-pipe solar receiver  

DOE Green Energy (OSTI)

Reflux heat-pipe receivers have been identified as a desirable interface to couple a Stirling-cycle engine with a parabolic dish solar concentrator. The reflux receiver provides power nearly isothermally to the engine heater heads while decoupling the heater head design from the solar absorber surface design. The independent design of the receiver and engine heater head leads to higher system efficiency. Heat pipe reflux receivers have been demonstrated at approximately 65 kW{sub t} power throughput. Several 25 to 30-kW{sub e} Stirling-cycle engines are under development, and will soon be incorporated in commercial dish-Stirling systems. These engines will require reflux receivers with power throughput limits reaching 90-kW{sub t}. The extension of heat pipe technology from 60 kW{sub t} to 100 kW{sub t} is not trivial. Current heat pipe wick technology is pushed to its limits. It is necessary to develop and test advanced wick structure technologies to perform this task. Sandia has developed and begun testing a Bekaert Corporation felt metal wick structure fabricated by Porous Metal Products Inc. This wick is about 95% porous, and has liquid permeability a factor of 2 to 8 times higher than conventional technologies for a given maximum pore radius. The wick has been successfully demonstrated in a bench-scale heat pipe, and a full-scale on-sun receiver has been fabricated. This report details the wick design, characterization and installation into a heat pipe receiver, and the results of the bench-scale tests are presented. The wick performance is modeled, and the model results are compared to test results.

Andraka, C.E.; Adkins, D.R.; Moss, T.A. [Sandia National Labs., Albuquerque, NM (United States); Cole, H.M. [Porous Metal Products, Jacksboro, TX (United States); Andreas, N.H. [Bekaert Corp., Marietta, GA (United States)

1994-12-31T23:59:59.000Z

464

Managing time  

Science Conference Proceedings (OSTI)

Professionals overwhelmed with information glut can find hope from new insights about time management.

Peter J. Denning

2011-03-01T23:59:59.000Z

465

Independent review of estimated load reductions for PJM's small customer load response pilot project  

E-Print Network (OSTI)

of Estimated Load Reductions for PJM’s Small Customer Loadof Estimated Load Reductions for PJM’s Small Customer LoadResponse Pilot Project Prepared for PJM Interconnection, LLC

Heffner, G.; Moezzi, M.; Goldman, C.

2004-01-01T23:59:59.000Z

466

2012 CERTS LAAR Program Peer Review - Frequency Responsive Load Evaluation and Benefits - Isabelle Snyder, ORNL  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Frequency responsive loads Isabelle Snyder, Ph.D. Power and Energy Systems Group ORNL 2 Managed by UT-Battelle for the U.S. Department of Energy Presentation_name Project objective * Study the use of load for frequency regulation: - Identify frequency measurement accuracies based on different approaches - Identify accuracy requirement for frequency responsive load applications - Study the impact of frequency responsive loads on a large system (ERCOT or EI) 3 Managed by UT-Battelle for the U.S. Department of Energy Presentation_name Major technical accomplishments: overview * Identified requirements of measurement devices to satisfy accuracy requirements for frequency measurement * Initiated request for ERCOT and EI models: - ERCOT (market participant's concern about releasing ERCOT

467

Automated fuel pin loading system  

DOE Patents (OSTI)

An automated loading system for nuclear reactor fuel elements utilizes a gravity feed conveyor which permits individual fuel pins to roll along a constrained path perpendicular to their respective lengths. The individual lengths of fuel cladding are directed onto movable transports, where they are aligned coaxially with the axes of associated handling equipment at appropriate production stations. Each fuel pin can be reciprocated axially and/or rotated about its axis as required during handling steps. The fuel pins are inserted as a batch prior to welding of end caps by one of two disclosed welding systems.

Christiansen, David W. (Kennewick, WA); Brown, William F. (West Richland, WA); Steffen, Jim M. (Richland, WA)

1985-01-01T23:59:59.000Z

468

High loading uranium fuel plate  

DOE Patents (OSTI)

Two embodiments of a high uranium fuel plate are disclosed which contain a meat comprising structured uranium compound confined between a pair of diffusion bonded ductile metal cladding plates uniformly covering the meat, the meat having a uniform high fuel loading comprising a content of uranium compound greater than about 45 Vol. % at a porosity not greater than about 10 Vol. %. In a first embodiment, the meat is a plurality of parallel wires of uranium compound. In a second embodiment, the meat is a dispersion compact containing uranium compound. The fuel plates are fabricated by a hot isostatic pressing process.

Wiencek, Thomas C. (Bolingbrook, IL); Domagala, Robert F. (Indian Head Park, IL); Thresh, Henry R. (Palos Heights, IL)

1990-01-01T23:59:59.000Z

469

Definition: Congestion Management Report | Open Energy Information  

Open Energy Info (EERE)

Management Report Management Report Jump to: navigation, search Dictionary.png Congestion Management Report A report that the Interchange Distribution Calculator issues when a Reliability Coordinator initiates the Transmission Loading Relief procedure. This report identifies the transactions and native and network load curtailments that must be initiated to achieve the loading relief requested by the initiating Reliability Coordinator.[1] View on Wikipedia Wikipedia Definition Related Terms transmission lines, Reliability Coordinator, Interchange Distribution Calculator, transmission line, smart grid References ↑ Glossary of Terms Used in Reliability Standards An inli LikeLike UnlikeLike You like this.Sign Up to see what your friends like. ne Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Congestion_Management_Report&oldid=502584"

470

DSM Load Growth Through Electrotechnology Application Assistance  

E-Print Network (OSTI)

This paper will discuss how a new "win-win" approach is emerging that improves both customer competitiveness and utility energy sales as both DSM and the utility's relationship with its customers mature. While most DSM resources have been invested in conservation efforts, the efficient load building aspects must no longer be ignored. As DSM "returns to its roots," electrotechnology applications assistance programs are beginning to provide measured results that are a key part of utility efforts to manage demand. Several innovative electrotechnology application programs exist but most share a combination of the following key attributes: 1) Immediate results-oriented electrotechnology applications assistance and implementation is provided to key customers, 2) Market research is conducted on a broad category of customers to determine appropriate electrotechnology applications and assistance, 3) An advertising and promotional campaign development/ implementation plan is created, 4) Technology transfer training is provided for customers and utility staff, and 5) An assessment is made for the development of a regional technology application center.

Merchant, D. G.

1994-04-01T23:59:59.000Z

471

Loads on drillpipe during jarring operations  

Science Conference Proceedings (OSTI)

Jarring implies heavy loads on the drillstring. The highest load on the drillpipe before jarring is at the rig floor. This paper discusses loads on drillpipe before, under, and after jarring. The authors show that for most situations, the shock wave from the jar impact does not imply additional load on the drillpipe compared with static load. The theoretical results are confirmed by measurements of a jarring operation with stuck point at [approx] 1,200 m measured depth. Loads on the drillpipe can be a limited factor in jarring operations because fear of possible additional loads from jarring dynamics may restrict the trip force (overpull) on the jar. The main conclusion is that dynamic jar forces do not give additional loads on drillpipe. This information can be used to set an optimal trip force on the jar.

Aarrestad, T.V.; Kyllingstad, A.

1994-12-01T23:59:59.000Z

472

1994 Pacific Northwest Loads and Resources Study.  

Science Conference Proceedings (OSTI)

The 1994 Pacific Northwest Loads and Resources Study presented herein establishes a picture of how the agency is positioned today in its loads and resources balance. It is a snapshot of expected resource operation, contractual obligations, and rights. This study does not attempt to present or analyze future conservation or generation resource scenarios. What it does provide are base case assumptions from which scenarios encompassing a wide range of uncertainties about BPA`s future may be evaluated. The Loads and Resources Study is presented in two documents: (1) this summary of Federal system and Pacific Northwest region loads and resources and (2) a technical appendix detailing the loads and resources for each major Pacific Northwest generating utility. This analysis updates the 1993 Pacific Northwest Loads and Resources Study, published in December 1993. In this loads and resources study, resource availability is compared with a range of forecasted electricity consumption. The Federal system and regional analyses for medium load forecast are presented.

United States. Bonneville Power Administration.

1994-12-01T23:59:59.000Z

473

Spinning reserve from hotel load response  

SciTech Connect

Even though preliminary tests were not conducted during times of highest system or hotel loading during the summer, they showed that hotel load can be curtailed by 22 to 37 percent depending on the outdoor temperature and time of day. Full response occurred in 12 to 60 seconds from when the system operator's command to shed load was issued and the load drop was very rapid. (author)

Kirby, Brendan; Kueck, John; Laughner, Theo; Morris, Keith

2008-12-15T23:59:59.000Z

474

EM Receives Several Honors in 2011 DOE Sustainability Awards | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Receives Several Honors in 2011 DOE Sustainability Awards Receives Several Honors in 2011 DOE Sustainability Awards EM Receives Several Honors in 2011 DOE Sustainability Awards November 4, 2011 - 12:00pm Addthis Several EM employees, projects and teams were honored as part of the 2011 DOE Sustainability Awards announced this week. The awards recognize the achievements of DOE employees who saved taxpayer money by reducing the Department's use of energy, water, and paper, while improving the energy efficiency of government buildings and vehicles. EM award winners include an American Recovery and Reinvestment Act project to remediate tritium-contaminated debris at the Savannah River Site in an innovative, cost-effective way; the East Tennessee Technology Park, which was recognized for uniquely applying technology to create a paperless

475

Comments Received on Proposed Rulemaking for regulation implementing  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Received on Proposed Rulemaking for regulation Received on Proposed Rulemaking for regulation implementing section 216(h): Coordination of Federal Transmission Permitting on Federal Lands Comments Received on Proposed Rulemaking for regulation implementing section 216(h): Coordination of Federal Transmission Permitting on Federal Lands Section 1221(a) of EPAct 2005, which added section 216(h) to the Federal Power Act, stated that the U.S. Department of Energy (DOE) is to coordinate all Federal authorizations and related environmental reviews needed for siting interstate electric transmission projects, including National Environmental Policy Act of 1969 (NEPA) reviews. The purpose of this coordination is to streamline agencies' review processes and avoid duplication among Federal agencies. Section 216(h) of the Federal Power Act

476

DOE Waste Isolation Pilot Plant Receives EPA Recertification | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Waste Isolation Pilot Plant Receives EPA Recertification Waste Isolation Pilot Plant Receives EPA Recertification DOE Waste Isolation Pilot Plant Receives EPA Recertification March 29, 2006 - 9:42am Addthis CARLSBAD, NM - The U.S. Department of Energy's (DOE) Carlsbad Field Office today reached a significant milestone when its Waste Isolation Pilot Plant (WIPP) was recertified by the U.S. Environmental Protection Agency (EPA). This decision indicates that after a thorough evaluation of the physical state and performance of the facility, the WIPP meets EPA regulatory requirements for facilities that dispose of transuranic waste. The waste facility recertification process occurs every five years and is directed by Congress in the WIPP Land Withdrawal Act (LWA). "EPA's recertification reinforces the important mission of WIPP to safely

477

2012 Congestion Study Webinars to Present Preliminary Findings and Receive  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Congestion Study Webinars to Present Preliminary Findings and Congestion Study Webinars to Present Preliminary Findings and Receive Input from Stakeholders 2012 Congestion Study Webinars to Present Preliminary Findings and Receive Input from Stakeholders July 19, 2012 - 9:00am Addthis The Department of Energy will host three webinars in August 2012 to present the preliminary findings of the 2012 National Electric Transmission Congestion Study and to receive input and suggestions from state officials, industry representatives, and other stakeholders. Two of the webinars will be designed to discuss with state officials the initial findings of the DOE 2012 congestion analysis. The third webinar will be for industry representatives and other interested parties, although stakeholders may dial into any of the three meetings.

478

LANL spinoff receives NIH grant for respiratory disease diagnostic device  

NLE Websites -- All DOE Office Websites (Extended Search)

LANL spinoff receives NIH grant LANL spinoff receives NIH grant LANL spinoff receives NIH grant for respiratory disease diagnostic device Mesa Tech has been awarded a grant to develop an inexpensive, instrument-free, nucleic-acid testing device to diagnose various respiratory diseases in record time. October 19, 2011 Los Alamos National Laboratory sits on top of a once-remote mesa in northern New Mexico with the Jemez mountains as a backdrop to research and innovation covering multi-disciplines from bioscience, sustainable energy sources, to plasma physics and new materials. Los Alamos National Laboratory sits on top of a once-remote mesa in northern New Mexico with the Jemez mountains as a backdrop to research and innovation covering multi-disciplines from bioscience, sustainable energy

479

Two from APS Receive U. of C. Distinguished Performance Award  

NLE Websites -- All DOE Office Websites (Extended Search)

Two from APS Receive U. of C. Distinguished Performance Award Two from APS Receive U. of C. Distinguished Performance Award Wah-Keat Lee and Jin Wang (both ANL-XFD) are among five scientists from the U.S. Department of Energy's Argonne National Laboratory who have received the 2005 University of Chicago Board of Governors for Argonne Distinguished Performance Award, which recognizes outstanding scientific or technical achievements or a distinguished record of achievements. Wang and Lee are being honored for their success in using X-rays in a wide range of research. Wang is a world-renowned expert in the application of X-ray scattering to a variety of materials science problems. He is best known for his research into the dynamics of fuel sprays, where he applied an innovative research approach and achieved unique results. Lee, after

480

Newest Los Alamos facility receives LEED® Gold certification  

NLE Websites -- All DOE Office Websites (Extended Search)

Newest facility receives LEED® Gold certification Newest facility receives LEED® Gold certification Newest Los Alamos facility receives LEED® Gold certification The Radiological Laboratory Utility Office Building is first to achieve both the Leadership in Energy and Environmental Design status and LEED Gold certification. June 13, 2012 Radiological Laboratory Utility Office Building Radiological Laboratory Utility Office Building Contact Kim Powell Communications Office (505) 695-6159 Email LOS ALAMOS, New Mexico, June 13, 2012-Los Alamos National Laboratory's newest facility, the Radiological Laboratory Utility Office Building (RLUOB), is also its first to achieve both the Leadership in Energy and Environmental Design (LEED) status and LEED Gold certification from the U.S. Green Building Council (USGBC).

Note: This page contains sample records for the topic "load management receiver" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

NETL'S SHOCKLEY RECEIVES 2012 EXCELLENCE IN GOVERNMENT AWARD  

NLE Websites -- All DOE Office Websites (Extended Search)

SHOCKLEY RECEIVES 2012 EXCELLENCE IN GOVERNMENT SHOCKLEY RECEIVES 2012 EXCELLENCE IN GOVERNMENT AWARD Morgantown, W.Va. - The National Energy Technology Laboratory's (NETL) Darryl T. Shockley has been selected by the Pittsburgh Federal Executive Board (FEB) for their Excellence in Government Award for Outstanding Contribution to Science (Non-Medical), Silver level. The Award was presented at the 29th annual Awards Program luncheon at the Westin Convention Center Hotel in Pittsburgh on Friday, May 25. Out of the 160 nominations FEB received from regional Federal organizations, NETL was lauded with 3 Gold Awards, 2 Silver Awards, and 5 Bronze Awards. Representatives from 16 Federal agencies, acting as an FEB awards committee, made the semi-final selections, and a panel of representatives from the business and civic community chose

482

Argonne researcher and his colleagues receive best paper prize | Argonne  

NLE Websites -- All DOE Office Websites (Extended Search)

Argonne researcher and his colleagues receive best paper prize Argonne researcher and his colleagues receive best paper prize November 21, 2013 Tweet EmailPrint Sven Leyffer, senior computational mathematician in Argonne National Laboratory's Mathematics and Computer Science Division, and his colleagues Chungen Shen of Shanghai Finance University and Roger Fletcher of the University of Dundee received the 2012 Best Paper Prize for their paper "A nonmonotone filter method for nonlinear optimization." The paper, which appeared in the international journal Computational Optimization and Applications, was chosen by the editorial board from more than 130 papers. An article about the award-winning paper is featured in the November 2013 issue of the journal. "Our aim was to develop a method that avoided the use of old filter

483

Historically Black Colleges and Universities Receive Funds for Fossil  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Historically Black Colleges and Universities Receive Funds for Historically Black Colleges and Universities Receive Funds for Fossil Energy Research Historically Black Colleges and Universities Receive Funds for Fossil Energy Research August 15, 2013 - 1:18pm Addthis Washington, D.C. - Five fossil energy-related projects that will help maintain the nation's energy portfolio while also providing educational and research training opportunities for tomorrow's scientists and engineers have been selected for funding by the U.S. Department of Energy (DOE). The funding opportunity to enhance scientific and technical understanding of conversion and utilization of fossil fuels is through the Office of Fossil Energy's National Energy Technology Laboratory (NETL). The DOE program involved is the Support of Advanced Fossil Resource Utilization

484

Thirteen States Receive Energy Department Awards to Drive Greater Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

States Receive Energy Department Awards to Drive Greater States Receive Energy Department Awards to Drive Greater Energy Efficiency, Save Money Thirteen States Receive Energy Department Awards to Drive Greater Energy Efficiency, Save Money November 26, 2013 - 2:44pm Addthis News Media Contact (202) 586-4940 WASHINGTON - Building on the Obama Administration's efforts to double energy productivity by 2030 and help communities save on energy bills, the Energy Department today awarded nearly $4 million to 13 states to increase statewide energy savings and boost the energy efficiency of public institutions, local governments and industrial sectors. The Department's State Energy Program has a long history in assisting states in saving energy and deploying new clean energy technologies. "Smart, cost-effective investments in energy efficiency are helping

485

On Digital Radio Receiver Performance in Electromagnetic Interference Environments  

E-Print Network (OSTI)

adiated emission from electronic equipment, co-located to a digital radio receiver, can affect receiving performance. It is therefore of great importance that this undesired emission be considered in the early design phase of a system containing radio equipment. For this purpose, methods to estimate the performance degradation on digital radio receivers in such environment must be available. From a military point of view, such methods are necessary for at