Zero Carryover Liquid-Desiccant Air Conditioner for Solar Applications: Preprint  

DOE Green Energy (OSTI)

A novel liquid-desiccant air conditioner that dries and cools building supply air will transform the use of direct-contact liquid-desiccant systems in HVAC applications, improving comfort, air quality, and providing energy-efficient humidity control.

Lowenstein, A.; Slayzak, S.; Kozubal, E.

2006-07-01T23:59:59.000Z

2

Liquid Desiccant Drying of Thermoreversibly Gelcast Bodies  

Science Conference Proceedings (OSTI)

Presentation Title, Liquid Desiccant Drying of Thermoreversibly Gelcast Bodies. Author(s), Noah O Shanti, Katherine T Faber. On-Site Speaker (Planned), Noah ...

3

A Preliminary Evaluation of Alternative Liquid Desiccants for a Hybrid Desiccant Air Conditioner  

E-Print Network (OSTI)

This paper presents the results of a preliminary investigation at The University of Texas at Austin of alternative liquid desiccants for use in a hybrid desiccant air-conditioning system in which a desiccant is circulated between the evaporator and the condenser of a vapor-compression air conditioner. The liquid desiccants studied were lithium chloride, lithium bromide, calcium chloride, and triethylene glycol. Each candidate desiccant was subjected to a screening process which weighed the merits of the desiccant in terms of selected characteristics. The best liquid desiccant for the anticipated application was found to be calcium chloride.

Studak, J. W.; Peterson, J. L.

1988-01-01T23:59:59.000Z

4

Active Desiccant Dehumidification Module Integration with Rooftop Packaged HVAC  

Science Conference Proceedings (OSTI)

This report summarizes a research and development program that produced a stand-alone active desiccant module (ADM) that can be easily integrated with new or existing packaged cooling equipment. The program also produced a fully integrated hybrid system, combining the active desiccant section with a conventional direct expansion air-conditioning unit, that resulted in a compact, low-cost, energy-efficient end product. Based upon the results of this investigation, both systems were determined to be highly viable products for commercialization. Major challenges--including wheel development, compact packaging, regeneration burner development, control optimization, and low-cost design--were all successfully addressed by the final prototypes produced and tested as part of this program. Extensive laboratory testing was completed in the SEMCO laboratory for each of the two ADM system approaches. This testing confirmed the performance of the ADM systems to be attractive compared with that of alternate approaches currently used to precondition outdoor air, where a return air path is not readily available for passive desiccant recovery or where first cost is the primary design criterion. Photographs, schematics, and performance maps are provided for the ADM systems that were developed; and many of the control advantages are discussed. Based upon the positive results of this research and development program, field tests are under way for fully instrumented pilot installations of ADM systems in both a hotel/motel and a restaurant.

Fischer, J

2002-04-17T23:59:59.000Z

5

Analysis of Hybrid Liquid Desiccant Technologies  

Science Conference Proceedings (OSTI)

Dehumidification technology is being investigated for potential savings in building air conditioning systems. The potential for savings lies in separating the sensible and latent cooling loads to more efficiently address the combined conditioning needs of the space. Two DuCool liquid desiccant systemsDuTreat and DuHandlingwere tested in the Electric Power Research Institute (EPRI) Knoxville, Tennessee psychrometric chambers. The DuCool uses an internal vapor compression system to regenerate a liquid desi...

2011-05-09T23:59:59.000Z

6

New and Underutilized Technology: Liquid Desiccant Air Conditioner |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Liquid Desiccant Air Conditioner Liquid Desiccant Air Conditioner New and Underutilized Technology: Liquid Desiccant Air Conditioner October 4, 2013 - 4:40pm Addthis The following information outlines key deployment considerations for liquid desiccant air conditioners (LDACs) within the Federal sector. Benefits Liquid desiccant air conditioners deeply dry air using natural gas, solar energy, waste heat, bio-fuel, or other fossil fuels to drive the system. By providing mostly latent cooling, the LDAC controls indoor humidity without overcooling and reheating. This unit is supplemented by an electric chiller or DX air conditioner that sensibly cools the building's recirculation air. The liquid desiccant is a concentrated salt solution that directly absorbs moisture. Application LDACs are applicable in hospital, office, prison, school, and service

7

Performance analysis of hybrid liquid desiccant solar cooling system.  

E-Print Network (OSTI)

??This thesis investigates the coefficient of performance (COP) of a hybrid liquid desiccant solar cooling system. This hybrid cooling system includes three sections: 1) conventional… (more)

Zhou, Zhipeng (Joe Zoe)

2009-01-01T23:59:59.000Z

8

Field Evaluation of Desiccant-Integrated HVAC Systems: A Review of Case Studies in Multiple Commercial/Institutional Building Types  

E-Print Network (OSTI)

An independent field research effort co-funded by the Gas Research Institute and The U.S. Department of Energy (DOE) Oak Ridge National Laboratory is documenting the performance and energy usage characteristics of active desiccant-integrated HVAC systems at a variety of commercial and institutional facilities. The tests comprise the instrumentation and one-year-plus monitoring of two or more nearly identical sites, one serving as the test site and the others as base-case or control sites. While the research program is ongoing, work completed in two market sectors, retail and lodging, indicates that there are significant comfort control, energy usage and equipment efficiency benefits to be derived from integrating desiccant units into HVAC system design to handle latent and sensible loads independently. In some cases, installed first costs associated with including desiccant units may be lower if the HVAC system is optimized to take advantage of reduced conventional cooling equipment requirements and downsized ductwork In most cases, lower energy consumption and/or reduced energy costs may provide reasonable payback of first cost premiums.

Yborra, S. C.

1998-01-01T23:59:59.000Z

9

Using liquid desiccant as a regenerable filter for capturing and deactivating contaminants  

DOE Patents (OSTI)

A method, and systems for implementing such method, for purifying and conditioning air of weaponized contaminants. The method includes wetting a filter packing media with a salt-based liquid desiccant, such as water with a high concentration of lithium chloride. Air is passed through the wetted filter packing media and the contaminants in are captured with the liquid desiccant while the liquid desiccant dehumidifies the air. The captured contaminants are then deactivated in the liquid desiccant, which may include heating the liquid desiccant. The liquid desiccant is regenerated by applying heat to the liquid desiccant and then removing moisture. The method includes repeating the wetting with the regenerated liquid desiccant which provides a regenerable filtering process that captures and deactivates contaminants on an ongoing basis while also conditioning the air. The method may include filtration effectiveness enhancement by electrostatic or inertial means.

Slayzak, Steven J. (Denver, CO); Anderson, Ren S. (Broomfield, CO); Judkoff, Ronald D. (Golden, CO); Blake, Daniel M. (Golden, CO); Vinzant, Todd B. (Golden, CO); Ryan, Joseph P. (Golden, CO)

2007-12-11T23:59:59.000Z

10

Analysis of a Flat-Plate, Liquid-Desiccant, Dehumidifier and Regenerator.  

E-Print Network (OSTI)

??A numerical model for isothermal and non-isothermal flat-plate liquid-desiccant dehumidifiers and regenerators was developed and implemented. The two-dimensional model takes into account the desiccant, water… (more)

Mesquita, Lucio Cesar De Souza

2008-01-01T23:59:59.000Z

11

High Efficiency Liquid-Desiccant Regenerator for Air Conditioning and Industrial Drying  

SciTech Connect

Over 2 quads of fossil fuels are used each year for moisture removal. This includes industrial and agricultural processes where feedstocks and final products must be dried, as well as comfort conditioning of indoor spaces where the control of humidity is essential to maintaining healthy, productive and comfortable working conditions. Desiccants, materials that have a high affinity for water vapor, can greatly reduce energy use for both drying and dehumidification. An opportunity exists to greatly improve the competitiveness of advanced liquid-desiccant systems by increasing the efficiency of their regenerators. It is common practice within the chemical process industry to use multiple stage boilers to improve the efficiency of thermal separation processes. The energy needed to regenerate a liquid desiccant, which is a thermal separation process, can also be reduced by using a multiple stage boiler. In this project, a two-stage regenerator was developed in which the first stage is a boiler and the second stage is a scavenging-air regenerator. The only energy input to this regenerator is the natural gas that fires the boiler. The steam produced in the boiler provides the thermal energy to run the second-stage scavenging-air regenerator. This two-stage regenerator is referred to as a 1?-effect regenerator. A model of the high-temperature stage of a 1?-effect regenerator for liquid desiccants was designed, built and successfully tested. At nominal operating conditions (i.e., 2.35 gpm of 36% lithium chloride solution, 307,000 Btu/h firing rate), the boiler removed 153 lb/h of water from the desiccant at a gas-based efficiency of 52.9 % (which corresponds to a COP of 0.95 when a scavenging-air regenerator is added). The steam leaving the boiler, when condensed, had a solids concentration of less than 10 ppm. This low level of solids in the condensate places an upper bound of about 6 lb per year for desiccant loss from the regenerator. This low loss will not create maintenance problems nor will it significantly increase operating expenses. An energy balance on the boiler showed that heat loss through the insulated jacket was 10%. This value is much higher than the 2% to 5% that is typical of most boilers and indicates a need to better insulate the unit. With insulation that brings jacket losses down to 5%, a 1?-effect regenerator that uses this boiler as its high-temperature stage will have a gas-based COP of 1.05. The estimated cost to manufacture a 300-lb/h, 1?-effect regenerator at 500 units per year is $17,140. Unfortunately, the very high cost for natural gas that now prevails in the U.S. makes it very difficult for a gas-fired LDAC to compete against an electric vapor-compression air conditioner in HVAC applications. However, there are important industrial markets that need very dry air where the high price of natural gas will encourage the sale of a LDAC with the 1?-effect regenerator since in these markets it competes against less efficient gas-fired desiccant technologies. A manufacturer of industrial dehumidification equipment is now negotiating a sales agreement with us that would include the 1?-effect regenerator.

Andrew Lowenstein

2005-12-19T23:59:59.000Z

12

Photovoltaic-electrodialysis regeneration method for liquid desiccant cooling system  

Science Conference Proceedings (OSTI)

Liquid desiccant cooling system (LDCS) is an (a novel) air-conditioning system with good energy saving potential. Regenerator is the power centre for LDCS. Currently, the regeneration process is always fuelled by thermal energy. Nevertheless, this regeneration pattern has some disadvantages in that its performance will become poor when the surrounding atmosphere is of high humidity, and the heat provided for regeneration will be unfavourable to the following dehumidification process. To ameliorate that, a new regeneration method is proposed in this paper: a membrane regenerator is employed to regenerate the liquid desiccant in an electrodialysis way; while solar photovoltaic generator is adopted to supply electric power for this process. Analysis has been made about this new regeneration method and the result reveals: this new manner achieves good stability with the immunity against the adverse impact from the outside high humidity; its performance is much higher than that of the thermal regeneration manner while putting aside the low efficiency of the photovoltaic system. Besides, purified water can be obtained in company with the regeneration process. (author)

Li, Xiu-Wei [College of Power Engineering, Nanjing University of Science and Technology, Nanjing 210094 (China); Zhang, Xiao-Song [School of Energy and Environment, Southeast University, Nanjing 210096 (China)

2009-12-15T23:59:59.000Z

13

Energy-efficient regenerative liquid desiccant drying process  

DOE Patents (OSTI)

This invention relates to the use of desiccants in conjunction with an open oop drying cycle and a closed loop drying cycle to reclaim the energy expended in vaporizing moisture in harvested crops. In the closed loop cycle, the drying air is brought into contact with a desiccant after it exits the crop drying bin. Water vapor in the moist air is absorbed by the desiccant, thus reducing the relative humidity of the air. The air is then heated by the used desiccant and returned to the crop bin. During the open loop drying cycle the used desiccant is heated (either fossil or solar energy heat sources may be used) and regenerated at high temperature, driving water vapor from the desiccant. This water vapor is condensed and used to preheat the dilute (wet) desiccant before heat is added from the external source (fossil or solar). The latent heat of vaporization of the moisture removed from the desiccant is reclaimed in this manner. The sensible heat of the regenerated desiccant is utilized in the open loop drying cycle. Also, closed cycle operation implies that no net energy is expended in heating drying air.

Ko, Suk M. (Huntsville, AL); Grodzka, Philomena G. (Huntsville, AL); McCormick, Paul O. (Athens, AL)

1980-01-01T23:59:59.000Z

14

Experimental study of the heat and mass transfer in a packed bed liquid desiccant air dehumidifier  

Science Conference Proceedings (OSTI)

Desiccant cooling systems have the ability to provide efficient humidity and temperature control while reducing the electrical energy requirement for air conditioning as compared to a conventional system. Naturally, the desiccant air dehumidification process greatly influences the overall performance of the desiccant system. Therefore, the effects of variables such as air and desiccant flow rates, air temperature and humidity, desiccant temperature and concentration, and the area available for heat and mass transfer are of great interest. Due to the complexity of the dehumidification process, theoretical modeling relies heavily upon experimental studies. However, a limited number of experimental studies are reported in the literature. This paper presents results from a detailed experimental investigation of the heat and mass transfer between a liquid desiccant (triethylene glycol) and air in a packed bed absorption tower using high liquid flow rates. A high performance packing that combines good heat and mass transfer characteristics with low pressure drop is used. The rate of dehumidification, as well as the effectiveness of the dehumidification process are assessed based on the variables listed above. Good agreement is shown to exist between the experimental findings and predictions from finite difference modeling. In addition, a comparison between the findings in the present study and findings previously reported in the literature is made. The results obtained from this study make it possible to characterize the important variables which impact the system design.

Oeberg, V.; Goswami, D.Y. [Univ. of Florida, Gainesville, FL (United States)

1998-11-01T23:59:59.000Z

15

Heat and mass transfer in packed bed liquid desiccant regenerators -- An experimental investigation  

Science Conference Proceedings (OSTI)

Liquid desiccant cooling can provide control of temperature and humidity, while at the same time lowering the electrical energy requirement for air conditioning. Since the largest energy requirement associated with desiccant cooling is low temperature heat for desiccant regeneration, the regeneration process greatly influences the overall system performance. Therefore, the effects of variables such as air and desiccant flow rates, air temperature and humidity, desiccant temperature and concentration, and the area available for heat and mass transfer on the regeneration process are of great interest. Due to the complexity of the regeneration process, which involves simultaneous heat and mass transfer, theoretical modeling must be verified by experimental studies. However, a limited number of experimental studies are reported in the literature. This paper presents results from a detailed experimental investigation of the heat and mass transfer between a liquid desiccant (triethylene glycol) and air in a packed bed regenerator using high liquid flow rates. To regenerate the desiccant, it is heated to temperatures readily obtainable from flat-plate solar collectors. A high performance packing that combines good heat and mass transfer characteristics with low pressure drop is used. The rate of water evaporation, as well as the effectiveness of the regeneration process is assessed based on the variables listed above. Good agreement is shown to exist between the experimental findings and predictions from finite difference modeling. In addition, the findings in the present study are compared to findings previously reported in the literature. Also, the results presented here characterize the important variables that impact the system design.

Martin, V.; Goswami, D.Y.

1999-08-01T23:59:59.000Z

16

Performance characteristics of open-flow liquid desiccant solar collector/regenerator for solar cooling applications. Part 2. System simulation and performance measurements. Final report  

DOE Green Energy (OSTI)

This research focussed on the performance and system simulation of an open-flow liquid desiccant solar collector/regenerator.

Wood, B.D.; Siebe, D.A.; Applebaum, M.A.; Novak, K.S.; Ballew, L.M.

1983-11-01T23:59:59.000Z

17

Solar Desiccant Cooling  

NLE Websites -- All DOE Office Websites (Extended Search)

Solar Desiccant Cooling Solar Desiccant Cooling Speaker(s): Paul Bourdoukan Date: December 6, 2007 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Ashok Gadgil The development of HVAC systems is a real challenge regarding its environmental impact. An innovative technique operating only by means of water and solar energy, is desiccant cooling. The principle is evaporative cooling with the introduction of a dehumidification unit, the desiccant wheel to control the humidity levels. The regeneration of the desiccant wheel requires a preheated airstream. A solar installation is a very interesting option for providing the preheated airstream. In France, at the University of La Rochelle, and at the National Institute of Solar Energy (INES), the investigation of the solar desiccant cooling technique has been

18

Liquid-desiccant systems for cooling/drying applications  

SciTech Connect

Thermally-driven desiccant cooling systems have been investigated extensively during the past decade as economically competitive alternatives to vapor-compression cooling systems. A differential formulation is used to model the commercial Kathabar System to describe the heat and mass transfer for a control volume in both the conditioner and the generator. These differential equations depend on parameters, depending on the flow rate of the fluids (water, air and solution), the physical properties of these fluids, the geometry of the transfer surfaces and the heat and mass transfer coefficients. The flat-plate solar collector does not give a satisfactory results if it is used to heat the generator outlet water, because the water coming out from the generator is at about 80 C which is too high to be heated again by a flat-plate collector. The air coming from the conditioner is used for drying corn. The use of the Kathabar System for drying applications is infeasible. The Kathabar system mathematical model was modified by running the conditioner adiabatically. The governing equations became 4 first-order partial differential equations instead of 6 equations. The same numerical scheme is used to solve these equations. The air coming from the new system conditioner is used for drying corn.

Mahmoud, K.G.

1987-01-01T23:59:59.000Z

19

Experimental Investigation on the Operation Performance of a Liquid Desiccant Air-conditioning System  

E-Print Network (OSTI)

A large share of energy consumption is taken by an air-conditioning system. It worsens the electricity load of the power network. Therefore, more and more scholars are paying attention to research on new types of air-conditioning systems that are energy- saving and environment-friendly. A liquid desiccant air conditioning system is among them, as it has a tremendous ability for power storage and low requirements for heat resources. Heat with low temperatures, such as excess heat, waste heat, and solar power, is suitable for the liquid desiccant air-conditioning system. The feasibility and economical efficiency of the system are studied in this experimental research. The result shows that when the temperature of the regeneration is about 80?, the thermodynamic coefficient of the system is about 0.6, and the supply air temperature of the air-conditioning system remains stable at 21?, the air-conditioning system can meet human comfort levels.

Liu, J.; Wang, J.; Wu, Z.; Gu, W.; Zhang, G.

2006-01-01T23:59:59.000Z

20

Simulation and study of thermal performance of liquid desiccant cooling cycle configurations  

E-Print Network (OSTI)

Five configurations of a 3-ton liquid desiccant cooling cycle were simulated and analyzed on a digital computer. Algebraic equations were developed for the dry bulbtemperatures and humidity ratios at different locations in the systems and solved using a finite difference scheme. The simulations were done at steady state and standard ASHRAE indoor and outdoor conditions. The study compared thermal performance of these five system configurations consisting of a direct evaporative cooler, indirect evaporative cooler(s), liquid desiccant packed dehumidifying tower, and air-to-air heat exchanger. Constant effectiveness of 0.85 and 0.9 were assumed for the direct evaporative cooler and air-to-air heat exchanger respectively. The performance of these five cycles is judged by the thermal Coefficient of Performance (COP). The Sensible Heat Ratio (SHR) is used to quantify the ratio of sensible cooling provided to the total cooling done (sensible plus latent).

Dhir, Rajesh

1995-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "liquid desiccant hvac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Experimental performance verification of a coil-type liquid desiccant system at part-load operation  

SciTech Connect

An experimental study was conducted to compare the predicted performance of a commercially available coil type liquid desiccant cooling and dehumidification system with the experimental results at part-load conditions. A mathematical model was used to predict the performance of coil type liquid desiccant system. This model was based mostly on the manufacturer's catalog data. The coil type system used in the experimental study was a system manufactured in the US. The system is commercially available as 200-10 KXCb, 10-row deep conditioner unit with a design air flow rate of 1180 1/s(2500 scfm). For regeneration of the solution, a packed type 3.0-P regenerator unit with a design air flow rate of 448.4 1/s(950 scfm) was used.

Khan, A.Y. (Univ. of Puerto Rico, Mayaguez (Puerto Rico)); Ball, H.D. (Kansas State Univ., Manhattan, KS (United States))

1993-11-01T23:59:59.000Z

22

Passive features for a liquid desiccant air conditioner  

SciTech Connect

A conceptual development program with the ultimate objective of substantially reducing or eliminating the parasitic power requirement for liquid sorbent air conditioning systems is described. Operational tests conducted on small prototypes have shown that some of the pumps can be replaced with other apparatus requiring no electrical energy. Experimental work has also shown that some electric utility dependent pumps might be replaced by solar powered pumps thus making the system more passive in nature.

Francis, C.E.; Beavers, D.R.

1980-01-01T23:59:59.000Z

23

Cooling and Dehumidification HVAC Technology for 1990s  

E-Print Network (OSTI)

Desiccant Cooling and Dehumidification HVAC Technology for 1990s HVAC: Heating, Ventilation Research Trusts SERI #12;Challenges Facing HVAC Industry in 1990's * Reduction of CFCs * Indoor air quality to solve the problems of the HVAC industry faced in1990's for space conditioning. SERI #12;l- = m mN a- mg

Oak Ridge National Laboratory

24

Solar liquid-desiccant air-conditioning system. Final report  

DOE Green Energy (OSTI)

A design for a closed, diurnal, intermittent absorption chiller for passive solar air-conditioning using liquid sorbents has been constructed and tested. LiBr-H/sub 2/O will not work with this design because of its low vapor pressure at the temperature available. The approach has possibilities using the 2 LiBr-ZrBr-CH/sub 3/OH or H/sub 2/O-NH/sub 3/ sorbent refrigerant pairs. The use of H/sub 2/O-NH/sub 3/ appears to be the better candidate because of the lower solution viscosity and less cycle weight, through tank volumes and collector requirements are similar. Further study of other refrigerant pairs such as S-Thiocyanate-ammonia is indicated, however, the difficulties encountered in construction and low potential coefficient of performance, and thus large collection area needed, makes commercialization of such a system doubtful in the foreseeable future.

Not Available

25

Analysis and design of a solar-powered liquid-desiccant air conditioner for use in hot and humid climates  

SciTech Connect

An experimental and theoretical investigation of the feasibility of a solar-powered liquid-desiccant air conditioner, for use in hot and humid climates, was carried out at the Mechanical Engineering Department, University of Florida. The proposed liquid desiccant system used nonadiabatic contactors, packed with finned-tube coils, for both moist air dehumidification and liquid-desiccant regeneration. A theoretical model was developed to analyze the complex phenomena of simultaneous heat and mass transfer in nonadiabatic contactors, as well as the continuous interaction between the dehumidification and regeneration processes. A computer code was written to assist in the analysis of the dehumidification and regeneration processes separately and coupled, for continuous operation. It was used to investigate the interaction between the different controlling parameters and their effects on the overall performance of the desiccant system. A fully solar-powered liquid-desiccant air-conditioner, with three tons of capacity was designed and optimized including economical criteria. The overall coefficient of performance (COP) of the optimized system was determined to be 0.312.

Chebbah, A.

1987-01-01T23:59:59.000Z

26

Solar-Powered, Liquid-Desiccant Air Conditioner for Low-Electricity Humidity Control: Report and Summary Report  

DOE Green Energy (OSTI)

The primary objective of this project was to demonstrate the capabilities of a new high-performance, liquid-desiccant dedicated outdoor air system (DOAS) to enhance cooling efficiency and comfort in humid climates while substantially reducing electric peak demand at Tyndall Air Force Base (AFB), which is 12 miles east of Panama City, Florida.

Dean, J.; Kozubal, E.; Herrmann, L.; Miller, J.; Lowenstein, A.; Barker, G.; Slayzak, S.

2012-11-01T23:59:59.000Z

27

Seminar 14 - Desiccant Enhanced Air Conditioning: Desiccant Enhanced Evaporative Air Conditioning (Presentation)  

SciTech Connect

This presentation explains how liquid desiccant based coupled with an indirect evaporative cooler can efficiently produce cool, dry air, and how a liquid desiccant membrane air conditioner can efficiently provide cooling and dehumidification without the carryover problems of previous generations of liquid desiccant systems. It provides an overview to a liquid desiccant DX air conditioner that can efficiently provide cooling and dehumidification to high latent loads without the need for reheat, explains how liquid desiccant cooling and dehumidification systems can outperform vapor compression based air conditioning systems in hot and humid climates, explains how liquid desiccant cooling and dehumidification systems work, and describes a refrigerant free liquid desiccant based cooling system.

Kozubal, E.

2013-02-01T23:59:59.000Z

28

Zero Carryover Liquid-Desiccant Air Conditioner for Solar Applications: Preprint  

NLE Websites -- All DOE Office Websites (Extended Search)

A Zero Carryover A Zero Carryover Liquid-Desiccant Air Conditioner for Solar Applications Preprint A. Lowenstein AIL Research, Inc. S. Slayzak and E. Kozubal National Renewable Energy Laboratory To be presented at ASME International Solar Energy Conference (ISEC2006) Denver, Colorado July 8-13, 2006 Conference Paper NREL/CP-550-39798 July 2006 NOTICE The submitted manuscript has been offered by an employee of the Midwest Research Institute (MRI), a contractor of the US Government under Contract No. DE-AC36-99GO10337. Accordingly, the US Government and MRI retain a nonexclusive royalty-free license to publish or reproduce the published form of this contribution, or allow others to do so, for US Government purposes. This report was prepared as an account of work sponsored by an agency of the United States government.

29

Efficiency of a liquid desiccant dehumidification system regenerated by using solar collectors/regenerators with photovoltaic fans  

Science Conference Proceedings (OSTI)

A hybrid solar dehumidification air-conditioning system was used to study the absorption of water vapor from moist air by contacting the air with aqueous solutions that contained from 90 to 94% triethylene glycol (TEG). For the packings of 2-inch polypropylene Jaeger Tri-Packs, which have a surface-to-volume ratio of 157 m{sup 2}/m{sup 3} (48 ft{sup 2}/ft{sup 3}), the efficiency of dehumidification can reach 93.3%. The environmental air was introduced into the dehumidifier cocurrently flowing with the liquid desiccant, and the liquid desiccant was sprayed on the top of the packing material. The air-to-liquid mass flow ratio was controlled in a range of 0.46 to 1.36. As the moisture was absorbed from air by the TEG solution, the solution was diluted. The regeneration of the solution was carried out in 20-piece (38.8 m{sup 2}) basin-type solar collectors/regenerators whose regeneration coefficients of performance are above 0.2. Air generated by photovoltaic fans was blown into the solar collectors/regenerators and carried away the water vapor from the evaporation of the aqueous desiccant solution. On the basis of the experimental results, the system performance is acceptable for most applications.

Tsair-Wang Chung; Wei-Yih Wu; Wen-Jih Yan; Ching-Lin Huang [Industrial Technology Research Institute, Taiwan (China)

1995-04-01T23:59:59.000Z

30

Zero Energy Communities with Central Solar Plants using Liquid Desiccants and Local Storage: Preprint  

DOE Green Energy (OSTI)

The zero energy community considered here consists of tens to tens-of-thousands of residences coupled to a central solar plant that produces all the community's electrical and thermal needs. A distribution network carries fluids to meet the heating and cooling loads. Large central solar systems can significantly reduce cost of energy vs. single family systems, and they enable economical seasonal heat storage. However, the thermal distribution system is costly. Conventional district heating/cooling systems use a water/glycol solution to deliver sensible energy. Piping is sized to meet the peak instantaneous load. A new district system introduced here differs in two key ways: (i) it continuously distributes a hot liquid desiccant (LD) solution to LD-based heating and cooling equipment in each home; and (ii) it uses central and local storage of both LD and heat to reduce flow rates to meet average loads. Results for piping sizes in conventional and LD thermal communities show that the LD zero energy community reduces distribution piping diameters meeting heating loads by {approx}5X and meeting cooling loads by {approx}8X for cooling, depending on climate.

Burch, J.; Woods, J.; Kozubal, E.; Boranian, A.

2012-08-01T23:59:59.000Z

31

Thermally Activated Desiccant Technology for Heat Recovery and Comfort  

DOE Green Energy (OSTI)

Desiccant cooling is an important part of the diverse portfolio of Thermally Activated Technologies (TAT) designed for conversion of heat for the purpose of indoor air quality control. Thermally activated desiccant cooling incorporates a desiccant material that undergoes a cyclic process involving direct dehumidification of moist air and thermal regeneration. Desiccants fall into two categories: liquid and solid desiccants. Regardless of the type, solid or liquid, the governing principles of desiccant dehumidification systems are the same. In the dehumidification process, the vapor pressure of the moist air is higher than that of the desiccant, leading to transfer of moisture from the air to the desiccant material. By heating the desiccant, the vapor pressure differential is reversed in the regeneration process that drives the moisture from the desiccant. Figure 1 illustrates a rotary solid-desiccant dehumidifier. A burner or a thermally compatible source of waste heat can provide the required heat for regeneration.

Jalalzadeh, A. A.

2005-11-01T23:59:59.000Z

32

Active Humidity Control Through Gas-Fired Desiccant Humidity Pump  

E-Print Network (OSTI)

High equipment first cost and high operating costs, if electricity is used to drive such a system, have prohibited the application of active humidity control equipment in comfort conditioning in the past. Instead, passive techniques have been applied. A comparison of passive capacity control methods to control humidity shows that only the combined face and bypass and variable air volume system shows improved performance with respect to space humidity control, dew point depression, and response to perturbations. A gas-fired desiccant humidity pump will provide economical humidity control in existing and new construction using VAV or constant volume air distribution systems. The humidity pump is designed as a packaged make-up air module. It is coupled to new or existing conventional air-conditioning system via a duct. It consists of a triple integrated heat-exchanger combining (liquid) desiccant dehumidification with indirect evaporative cooling, a brine interchanger, and a gas-fired brine heater to regenerate the desiccant. Field experiments of two humidity pumps on existing commercial buildings have been initiated. Each system dehumidifies 5000 scfm of make-up air to meet all the latent loads, which is then fed to conventional, electric-driven HVAC equipment which meet all the sensible loads.

Novosel, D.; Griffiths, W. C.

1988-01-01T23:59:59.000Z

33

Desiccant Cooling Systems - A Review  

E-Print Network (OSTI)

Desiccant cooling systems have been investigated extensively during the past decade as alternatives to electrically driven vapor compression systems because regeneration temperatures of the desiccant - about 160°F, can be achieved using natural gas or by solar systems. Comfort is achieved by reducing the moisture content of air by a solid or liquid desiccant and then reducing the temperature in an evaporative cooler (direct or indirect). Another system is one where the dehumidifier removes enough moisture to meet the latent portion of the load while the sensible portion is met by a vapor compression cooling system; desiccant regeneration is achieved by using the heat rejected from the condenser together with other thermal sources. At present, residential desiccant cooling systems are in actual operation but are more costly than vapor compression systems, resulting in relatively long payback periods. Component efficiencies need to be improved, particularly the efficiency of the dehumidifier.

Kettleborough, C. F.; Ullah, M. R.; Waugaman, D. G.

1986-01-01T23:59:59.000Z

34

Open cycle liquid desiccant dehumidifier and hybrid solar/electric absorption refrigeration system. Annual report, January 1993--December 1993. Calendar year 1993  

DOE Green Energy (OSTI)

This annual report presents work performed during calendar year 1993 by the Florida Solar Energy Center under contract to the US Department of Energy. Two distinctively different solar powered indoor climate control systems were analyzed: the open cycle liquid desiccant dehumidifier, and an improved efficiency absorption system which may be fired by flat plate solar collectors. Both tasks represent new directions relative to prior FSEC research in Solar Cooling and Dehumidification.

Nimmo, B.G.; Thornbloom, M.D.

1995-04-01T23:59:59.000Z

35

Renovating Residential HVAC Systems HVAC Systems  

E-Print Network (OSTI)

- 1 - LBNL 57406 Renovating Residential HVAC Systems HVAC Systems J.A. McWilliams and I.S. Walker and Air Conditioning), and Stacy Hunt and Ananda Harzell (IBACOS). #12;- 3 - Renovating Residential HVAC Guideline for Residential HVAC Retrofits (http

36

Building Energy Software Tools Directory : HVAC Solution  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC Solution Back to Tool Screenshot for HVAC Solution. Screenshot for HVAC Solution. Screenshot for HVAC Solution...

37

Desiccant dehumidification analysis  

E-Print Network (OSTI)

Desiccant dehumidification has been given increasing interest in the air conditioning industry. Compared with conventional vapor compression air conditioning systems, desiccant dehumidification saves energy by separating ...

Xing, Hai-Yun Helen, 1976-

2000-01-01T23:59:59.000Z

38

Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Desiccant Enhanced Evaporative Air Conditioning Desiccant Enhanced Evaporative Air Conditioning Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning May 29, 2012 - 5:22pm Addthis This breakthrough combines desiccant materials, which remove moisture from the air using heat, and advanced evaporative technologies to develop a cooling unit that uses 90 percent less electricity and up to 80 percent less total energy than traditional air conditioning. This solution, called the desiccant enhanced evaporative air conditioner (DEVAP), also controls humidity more effectively to improve the comfort of people in buildings. View the entire Lab Breakthrough playlist. What are the key facts? Recent materials advances and liquid desiccant advances to design the compact and cost-effective DEVAP system. DEVAP uses 90 percent less electricity and up to 80 percent less

39

Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning May 29, 2012 - 5:22pm Addthis This breakthrough combines desiccant materials, which remove moisture from the air using heat, and advanced evaporative technologies to develop a cooling unit that uses 90 percent less electricity and up to 80 percent less total energy than traditional air conditioning. This solution, called the desiccant enhanced evaporative air conditioner (DEVAP), also controls humidity more effectively to improve the comfort of people in buildings. View the entire Lab Breakthrough playlist. What are the key facts? Recent materials advances and liquid desiccant advances to design the compact and cost-effective DEVAP system.

40

Analysis of the seasonal performance of hybrid desiccant cooling systems  

DOE Green Energy (OSTI)

A simulation model for the liquid desiccant component of a hybrid system was developed. An analysis of experimental test data was conducted. The liquid desiccant component was examined and the sensitivity of its seasonal performance to changes in principal component variables was identified. Seasonal simulations were performed on different operation modes of a hybrid liquid desiccant cooling system. The results were analyzed in terms of estimated operational costs and compared to the equivalent cost estimation of a conventional cooling system. The study showed that the investigated liquid desiccant configuration usually will not lower the costs of operation. A suggestion of an improved system is made.

Sick, F.

1987-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "liquid desiccant hvac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

An assessment of desiccant cooling and dehumidification technology  

SciTech Connect

Desiccant systems are heat-actuated cooling and dehumidification technology. With the recent advances in this technology, desiccant systems can now achieve a primary energy coefficient of performance (COP) between 1.3 and 1.5, with potential to go to 1.7 and higher. It is becoming one of the most promising alternatives to conventional cooling systems. Two important and well-known advantages of desiccant cooling systems are that they are CFC free and they can reduce the electricity peak load. Another important but lesser-known advantage of desiccant technology is its potential for energy conservation. The energy impact study in this report indicated that a possible 13% energy saving in residential cooling and 8% in commercial cooling is possible. Great energy saving potential also exists in the industrial sector if industrial waste heat can be used for desiccant regeneration. The latest study on desiccant-integrated building heating, ventilating, and air conditioning (HVAC) systems indicated that the initial cost for the conventional cooling equipment was greatly reduced by using desiccant technology because of downsized compressors, fans, and ductworks. This cost reduction was more than enough to offset the cost of desiccant equipment. Besides, the system operation cost was also reduced. All these indicate that desiccant systems are also cost effective. This study provides an updated state-of-the-art assessment forsiccant technology in the field of desiccant materials, systems, computer models, and theoretical analyses. From this information the technology options were derived and the future research and development needs were identified. Because desiccant technology has already been applied in the commercial building sector with very encouraging results, it is expected that future market breakthroughs will probably start in this sector. A market analysis for the commercial building application is therefore included.

Mei, V.C.; Chen, F.C. [Oak Ridge National Lab., TN (United States); Lavan, Z. [Illinois Inst. of Tech., Chicago, IL (United States); Collier, R.K. Jr. [Collier Engineering Services, Merritt Island, FL (United States); Meckler, G. [Gershon Meckler Associates, P.C., Herndon, VA (United States)

1992-07-01T23:59:59.000Z

42

Desiccant contamination in desiccant cooling systems  

SciTech Connect

This paper presents the results of a desiccant contamination experiment and the impact of the obtained silica gel degradation data on the performance of a desiccant cooling system. A test apparatus was used to thermally cycle several desiccant samples and expose them to ambient'' humid air or contaminated'' humid air. The source of contamination was cigarette smoke. The exposed desiccant samples were removed after 0.5, 1, 2, or 4 months of exposure and their moisture capacities were measured. The silica get samples thermally cycled with ambient air showed a 5% to 30% to 70% of their moisture capacity. Using the obtained degradation data in a system, the impact of desiccant degradation on the performance of a desiccant cooling cycle was estimated. Depending on the degree of desiccant degradation, the decrease in thermal coefficient of performance (COP) and cooling capacity of the system was 10% to 35%. It was found that the COP and the cooling capacity of a system after desiccant degradation can be improved by increasing the rotational speed of the dehumidifier. This indicates that a simple engineering solution may exist to alleviate some type of degradations. 9 refs., 6 figs., 2 tabs.

Pesaran, A.A.

1990-08-01T23:59:59.000Z

43

HVAC Maintenance and Technologies  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC - HVAC - Maintenance and Technologies Federal Utility Partnership Working Group Meeting Providence, Rhode Island April 15, 2010 BY Ramin Faramarzi, P.E. Technology Test Centers (TTC) Design and Engineering Services Southern California Edison (SCE) www.sce.com/rttc 2 Outline * Introduction to SCE's TTC * Overview of energy challenges in California (CA) * Role of HVAC in CA's energy and demand equations * Factors affecting HVAC performance * Focus on SCE's research on maintenance faults * Next generation of HVAC equipment * HVAC technologies on SCE's TTC radar * Black boxes - do they all work? 3 SCE's Technology Test Centers * SCE applied research facilities located in Irwindale, CA comprised of 3 test beds: * Refrigeration * HVAC * Lighting * Coming Soon! - A new ZNE lab 4 Refrigeration Testing

44

HVAC Installed Performance  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC Installed Performance HVAC Installed Performance ESI, Tim Hanes Context * The building envelope has historically been the focus in residential homes. * The largest consumer of energy in residential homes is typically the HVAC system. * Testing the performance of the HVAC system has not been pursued to its full potential. Technical Approach * Currently very little performance testing is being done to the HVAC system. * The only way to know if a HVAC system is operating correctly is to measure the Btu/h. * This should be done at the equipment and at the the system. Recommended Guidance * Training of HVAC technicians, installers, and salespeople is a must. * If only the technician is trained than implementing the change will not happen. * Public awareness of proper installation and its

45

Retrofitting of Conditioning Systems for Existing Small Commercial Buildings - Analysis and Design of Liquid Desiccant - Vapor Compression Hybrid  

E-Print Network (OSTI)

The combination of several concepts of new energy technologies may make it possible to reduce the energy needs for thermal comfort, especially cooling and dehumidification, in small sized, single-story commercial buildings. The potentials and limitations of retrofit technology for these characteristic structures have been the focus of the experience gained through the design and installation of a system adapted to a building constructed in the early 1960's. The existing split package air conditioning system was combined with a desiccant air-conditioning unit with a waste heat and solar heat reclaim component. While this retrofit system is feasible, a number of questions remain to be considered regarding the design, installation and operation of the total system. This paper focuses on the practical applications of such a hybrid system - both architectural/construction issues and the mechanical components/system considerations.

Arnas, O. A.; McQueen, T. M.

1984-01-01T23:59:59.000Z

46

Numerical investigation of transient heat and mass transfer in a parallel-flow liquid-desiccant absorber  

E-Print Network (OSTI)

model for heat and mass transfer processes in internallyof coupled heat and mass transfer processes in liquidHeat and mass transfer in liquid des- iccant air-conditioning process

Diaz, Gerardo

2010-01-01T23:59:59.000Z

47

Multiple sensors with single HVAC system control  

E-Print Network (OSTI)

sensor; HVAC; control system; optimization; multi channeloptimization method is designed to be independent of the HVAC

Lin, Craig; Federspiel, Clifford; Auslander, David

2002-01-01T23:59:59.000Z

48

Overview of Open-Cycle Desiccant Cooling Systems and Materials  

DOE Green Energy (OSTI)

This paper has presented a review of the thermodynamics of three desiccant cooling cycles: the ventilation cycle, the recirculation cycle, and the Dunkle cycle. For the ventilation cycle the qualitative effects of changes in the effectiveness of individual components were analyzed. There are two possible paths to improved dehumidifier performance: changing the design of dehumidifiers using currently available desiccants so as to increase effectiveness without increasing parasitic losses, or developing new desiccants specifically tailored for solar cooling applications. The later part of this paper has considered the second option. A list of desirable desiccant properties was defined, properties of currently used solid and liquid desiccants were compared to this list, and a hypothetical desiccant type that would give improved system performance was discussed.

Collier, R.; Arnold, F.; Barlow, R.

1981-09-01T23:59:59.000Z

49

CALIFORNIA ENERGY Large HVAC Building  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Large HVAC Building Survey Information Database of Buildings over 100 Design of Large Commercial HVAC Systems research project, one of six research elements in the Integrated Design of Large Commercial HVAC Systems Integrated Design of Small Commercial HVAC Systems Integrated

50

BFRL: HVAC&R - Publications  

Science Conference Proceedings (OSTI)

HVAC&R Equipment Performance Group. Publications. Repeatability of Energy Consumption Test Results for Compact Refrigerators ...

51

HVAC Maintenance and Technologies | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC Maintenance and Technologies HVAC Maintenance and Technologies Presentation covers the HVAC maintenance and technologies, and is given at the Spring 2010 Federal Utility...

52

Wireless Demand Response Controls for HVAC Systems  

E-Print Network (OSTI)

Response Controls for HVAC Systems Clifford Federspiel,tests. Figure 5: Specific HVAC electric power consumptioncontrol, demand response, HVAC, wireless Executive Summary

Federspiel, Clifford

2010-01-01T23:59:59.000Z

53

MAPPING HVAC SYSTEMS FOR SIMULATION IN ENERGYPLUS  

E-Print Network (OSTI)

LBNL-XXXXX MAPPING HVAC SYSTEMS FOR SIMULATION IN ENERGYPLUSof California. MAPPING HVAC SYSTEMS FOR SIMULATION INpresent a conventional view of HVAC systems to the user, and

Basarkar, Mangesh

2013-01-01T23:59:59.000Z

54

Measuring Advances in HVAC Distribution System Design  

E-Print Network (OSTI)

Gabel and Andresen, HVAC Secondary Toolkil. Atlanta: ASHRAE,P_02 Measuring Advances in HVAC Distribution System Designdesign and operation of the HVAC thermal distribution system

Franconi, E.

2011-01-01T23:59:59.000Z

55

HVAC Installed Performance  

Energy.gov (U.S. Department of Energy (DOE))

This presentation was given at the Summer 2012 DOE Building America meeting on July 25, 2012, and addressed the question HVAC proper installation energy savings: over-promising or under-delivering?"

56

Advanced desiccant materials research  

DOE Green Energy (OSTI)

The long-range goal of this task is to understand the role of surface phenomena in desiccant cooling materials. The background information includes a brief introduction to desiccant cooling systems (DCS) and the role of the desiccant as a system component. The purpose, background, rationale, and long-term technical approach for studying advanced desiccant materials are then treated. Experimental methods for measuring water vapor sorption by desiccants are described, and the rationale is then given for choosing a quartz crystal microbalance (QCM) for measuring sorption isotherms, rates, and cyclic stability. Background information is given about the QCM, including the quartz crystal resonator itself, the support structure for the quartz crystal, and the advantages and limitations of a QCM. The apparatus assembled and placed into operation during CY 1985 is described. The functions of the principal components of the equipment, i.e., the QCM, vacuum system, pressure gauges, residual gas analyzer, constant temperature bath, and data acquisition system, are described as they relate to the water vapor sorption measurements now under way. The criteria for narrowing the potential candidates as advanced desiccant materials for the initial studies are given. Also given is a list of 20 principal candidate materials identified based on the criteria and data available in the literature.

Czanderna, A.W.; Thomas, T.M.

1986-05-01T23:59:59.000Z

57

Investigation of manganese dioxide as an improved solid desiccant  

DOE Green Energy (OSTI)

This report describes the preparation of a series of manganese oxides and an analysis of their sorptive, structural, and surface characteristics as low-energetic desiccants for passive dehumidification and active desiccant cooling systems. A cusped Type III isotherm for the adsorption of water is reported for the first time. The data are interpreted as evidence of a first-order phase change from a two-dimensional gas to a liquid film in the first reversibly adsorbed layer. It appears that the water adsorption characteristics of MnO/sub 2/ compared to standard desiccants which exhibit Type II isotherms are due at least in part to differences in the physical topography and electronic properties of the desiccant substrates: MnO/sub 2/ is a p-type semiconductor with essentially-flat, monoenergetic surface structures, while standard desiccants like silica gel are electronic insulators with irregular, heteroenergetic surfaces.

Fraioli, A.V.

1983-03-01T23:59:59.000Z

58

HVAC | OpenEI  

Open Energy Info (EERE)

HVAC HVAC Dataset Summary Description The following data-set is for a benchmark residential home for all TMY3 locations across all utilities in the US. The data is indexed by utility service provider which is described by its "unique" EIA ID ( Source National Renewable Energy Laboratory Date Released April 05th, 2012 (2 years ago) Date Updated April 06th, 2012 (2 years ago) Keywords AC apartment CFL coffeemaker Computer cooling cost demand Dishwasher Dryer Furnace gas HVAC Incandescent Laptop load Microwave model NREL Residential television tmy3 URDB Data text/csv icon Residential Cost Data for Common Household Items (csv, 14.5 MiB) Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Annually Time Period License License Open Data Commons Public Domain Dedication and Licence (PDDL)

59

BFRL: HVAC&R - Publications  

Science Conference Proceedings (OSTI)

HVAC&R Equipment Performance Group. Publications. Fundamental Aspects of the Application of Carbon Dioxide in Comfort Cooling. ...

60

VENTILATION (HVAC) FAILURE (BUILDING WIDE)  

E-Print Network (OSTI)

VENTILATION (HVAC) FAILURE (BUILDING WIDE) A failure or shutdown of the ventilation system will be signaled by cessation of the audible background "rumbling" sound of the building's HVAC system. As building durations. NOTE: Due to unpredictable pressure differentials in and around the labs during an HVAC failure

Strynadka, Natalie

Note: This page contains sample records for the topic "liquid desiccant hvac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Desiccant Enhanced Evaporative Air Conditioning: Parametric Analysis and Design; Preprint  

SciTech Connect

This paper presents a parametric analysis using a numerical model of a new concept in desiccant and evaporative air conditioning. The concept consists of two stages: a liquid desiccant dehumidifier and a dew-point evaporative cooler. Each stage consists of stacked air channel pairs separated by a plastic sheet. In the first stage, a liquid desiccant film removes moisture from the process (supply-side) air through a membrane. An evaporatively-cooled exhaust airstream on the other side of the plastic sheet cools the desiccant. The second-stage indirect evaporative cooler sensibly cools the dried process air. We analyze the tradeoff between device size and energy efficiency. This tradeoff depends strongly on process air channel thicknesses, the ratio of first-stage to second-stage area, and the second-stage exhaust air flow rate. A sensitivity analysis reiterates the importance of the process air boundary layers and suggests a need for increasing airside heat and mass transfer enhancements.

Woods, J.; Kozubal, E.

2012-10-01T23:59:59.000Z

62

Definition: HVAC | Open Energy Information  

Open Energy Info (EERE)

HVAC HVAC Jump to: navigation, search Dictionary.png HVAC An abbreviation for the heating, ventilation, and air-conditioning system; the system or systems that condition air in a building.[1] View on Wikipedia Wikipedia Definition HVAC is the technology of indoor and vehicular environmental comfort. HVAC system design is a subdiscipline of mechanical engineering, based on the principles of thermodynamics, fluid mechanics, and heat transfer. Refrigeration is sometimes added to the field's abbreviation as HVAC&R or HVACR, or ventilating is dropped as in HACR (such as the designation of HACR-rated circuit breakers). HVAC is important in the design of medium to large industrial and office buildings such as skyscrapers and in marine environments such as aquariums, where safe and

63

Solar Desiccant Laboratory experiments  

DOE Green Energy (OSTI)

The first validation attempts with experimental data on SERI's in-house absorption computer model are reported. The SERI Desiccant Test Loop design is shown. Some experimental runs were made to extend the validation over a wide range of inlet (temperature/humidity) conditions. (MHR)

Kutscher, C.F.

1981-05-01T23:59:59.000Z

64

Schools resolve IAQ/humidity problems with desiccant preconditioning  

Science Conference Proceedings (OSTI)

This article describes how desiccant-based total energy recovery systems were retrofitted to the mechanical systems at Willis Foreman Elementary and Spirit Creek Middle Schools to decouple the outdoor air latent load from the existing 3-ton packaged rooftop HVAC units. The resulting hybrid system maintains 50 to 52 percent relative humidity in the space while continuously providing 15 cfm per student of outdoor air to the facility (a three-fold increase of the original 5 cfm per student design) and does so in a very energy-efficient manner.

Smith, J.C. [James C. Smith and Associates, Augusta, GA (United States)

1996-04-01T23:59:59.000Z

65

High performance solar desiccant cooling system: performance evaluations and research recommendations  

DOE Green Energy (OSTI)

This report presents an assessment of the current status of solar desiccant cooling and makes recommendations for continued research to develop high performance systems competitive with conventional cooling systems. Solid desiccant, liquid desiccant, and hybrid systems combining desiccant dehumidifiers with vapor compressor units are considered. Currently, all desiccant systems fall somewhat short of being competitive with conventional systems. Hybrid systems appear to have the greatest potential in the short term. Solid systems are close to meeting performance goals. Development of high performance solid desiccant dehumidifiers based on parallel passage designs should be pursued. Liquid system collector/generators and efficient absorbers should receive attention. Model development is also indicated. Continued development by hybrid systems is directly tied to the above work.

Schlepp, D.R.; Schultz, K.J.

1984-09-01T23:59:59.000Z

66

Gas-fired desiccant dehumidification system field evaluation in a quick-service restaurant. Final report, October 1989  

Science Conference Proceedings (OSTI)

This report describes the results of a field evaluation of state-of-art desiccant dehumidification equipment in Houston, TX. The evaluation demonstrated that comfort control in a quick-service restaurant could be improved dramatically. However, available gas-fired desiccant dehumidification equipment is too expensive, inefficient, and unreliable to be considered for wide application in the restaurant industry. Results of a technical and economic analysis of four HVAC options in four U.S. cities indicated that improved comfort control could be achieved with only a modest increase in operating costs with an advanced system. This, coupled with the economic benefits achieved through lower indoor humidity such as improved crew performance and reduced maintenance costs, could justify the introduction of an advanced, integrated, HVAC system using desiccant technology which has an installed cost similar to current equipment.

Koopman, R.N.; Marciniak, T.J.

1989-10-01T23:59:59.000Z

67

Composite desiccant structure  

DOE Patents (OSTI)

A composite formed of small desiccant particles retained in a dark matrix composed of a porous binder containing a transition metal oxide with pores to provide moisture transport with respect to the particles, and metallic fibers to remove the heat of condensation during dehumidification and provide heat for the removal of moisture during regeneration. The moisture absorbing properties of the composite may be regenerated by exposure of the dark matrix to solar radiation with dehumidification occurring at night.

Fraioli, Anthony V. (Hawthorn Woods, IL); Schertz, William W. (Batavia, IL)

1987-01-01T23:59:59.000Z

68

Composite desiccant structure  

DOE Patents (OSTI)

This patent discloses a composite formed of small desiccant particles retained in a dark matrix composed of a porous binder containing a transition metal oxide with pores to provide moisture transport with respect to the particles, and metallic fibers to remove the heat of condensation during dehumidification and provide heat for the removal of moisture during regeneration. The moisture absorbing properties of the composite may be regenerated by exposure of the dark matrix to solar radiation with dehumidification occurring at night.

Fraioli, A.V.; Schertz, W.W.

1984-06-06T23:59:59.000Z

69

CALIFORNIA ENERGY Large HVAC Energy Impact Report  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Large HVAC Energy Impact Report Statewide Energy Impact Report are part of the Integrated Design of Large Commercial HVAC Systems research project. The reports: Productivity and Interior Environments Integrated Design of Large Commercial HVAC Systems Integrated Design

70

HVAC Sensors, Controls, and Human Feedback Interfaces  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC Sensors, HVAC Sensors, Controls, and Human Controls, and Human Feedback Interfaces Feedback Interfaces April 26, 2010 Dr. Amr Gado Emerson Climate Technologies Heating And...

71

Building Technologies Office: Transitioning Traditional HVAC...  

NLE Websites -- All DOE Office Websites (Extended Search)

Traditional HVAC Contractors to Whole House Performance Expert Meeting Building America hosted the "Transitioning Traditional HVAC Contractors to Whole House Performance...

72

Building Technologies Office: Transitioning Traditional HVAC...  

NLE Websites -- All DOE Office Websites (Extended Search)

Transitioning Traditional HVAC Contractors to Whole House Performance Expert Meeting to someone by E-mail Share Building Technologies Office: Transitioning Traditional HVAC...

73

Measuring Outdoor Airflow into HVAC Systems  

E-Print Network (OSTI)

MEASURING OUTDOOR AIRFLOW INTO HVAC SYSTEMS W i l l i a m J.minimum OA flow rate if HVAC system has an economizer

Fisk, William J.; Faulkner, David; Sullivan, Douglas P.

2005-01-01T23:59:59.000Z

74

Building Energy Software Tools Directory: HVAC Solution  

NLE Websites -- All DOE Office Websites (Extended Search)

design and specify HVAC equipment. Pick familiar objects like boilers, pumps, fan coils and air handlers and using drag and drop methods, connect them to form a HVAC...

75

Desiccant degradation in desiccant cooling systems: A system study  

Science Conference Proceedings (OSTI)

The authors predict the impact of desiccant degradation on the performance of an open-cycle desiccant cooling system in ventilation mode using the degradation data on silica gel obtained from a previous study. The degradation data were based on thermal cycling desiccant samples and exposing them to ambient or contaminated air. Depending on the degree of desiccant degradation, the decrease in the thermal coefficient of performance (COP) and the cooling capacity of the system for low-temperature regeneration was 10 percent to 35 percent. The 35 percent loss occurred based on the worst-case desiccant degradation scenario. Under more realistic conditions the loss in system performance is expected to be lower.

Pesaran, A.A. [National Renewable Energy Lab., Golden, CO (United States)

1993-11-01T23:59:59.000Z

76

HVAC Improvements for Existing Houses  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC Improvements for Existing Houses HVAC Improvements for Existing Houses Speaker(s): Chryséis Bovagnet Date: September 5, 2002 - 12:00pm Location: Bldg. 90 Many older houses in the US are either not well designed from a thermal point of view or have HVAC (Heating Ventilation and Air Conditioning) systems in need of repairs or improvements. The building envelopes tend to have poor insulation and lots of leakage, and the HVAC systems are inefficient. The cooling/heating equipment is often located outside of the conditioned space (e.g. in attics or crawlspaces) with ducts that leak and have poor insulation, which cause energy loss and bad occupant comfort on peak days or in extreme climates. We developed a series of retrofits that will allow us to reduce the energy consumption of residential HVAC

77

NREL: Technology Transfer - NREL's Industry Growth Forum  

... to 7AC Technologies, Inc., a Massachusetts company that is commercializing a novel membrane-based liquid desiccant HVAC system.

78

Impact of desiccant degradation on desiccant cooling system performance  

Science Conference Proceedings (OSTI)

The performance of open-cycle desiccant cooling systems depends on several factors, some of which can change beyond manufacturers' specifications. For example, the desiccant sorption process may degrade with time on exposure to airborne contaminants and thermal cycling. Desiccant degradation can reduce the performance of a dehumidifier and thus the performance of desiccant cooling systems. Using computer simulations and recent experimental data on silica gel, the impact of degradation was evaluated. Hypothetical degradations of desiccants with Type 1 moderate isotherms were also simulated. Depending on the degree and type of desiccant degradation, the decrease in thermal coefficient of performance (COP) and cooling capacity of the system was 10% to 35%. The 35% loss in system performance occurs when desiccant degradation is considered worst case. The simulations showed that the COP, and to a lesser degree the cooling capacity of these degraded systems, could be improved by increasing the rotational speed of the dehumidifier. It is shown that easy engineering solutions might be available for some types of degradations. 9 refs., 6 figs., 1 tab.

Pesaran, A.A.; Penney, T.R.

1990-09-01T23:59:59.000Z

79

Strategy Guideline: HVAC Equipment Sizing  

SciTech Connect

The heating, ventilation, and air conditioning (HVAC) system is arguably the most complex system installed in a house and is a substantial component of the total house energy use. A right-sized HVAC system will provide the desired occupant comfort and will run efficiently. This Strategy Guideline discusses the information needed to initially select the equipment for a properly designed HVAC system. Right-sizing of an HVAC system involves the selection of equipment and the design of the air distribution system to meet the accurate predicted heating and cooling loads of the house. Right-sizing the HVAC system begins with an accurate understanding of the heating and cooling loads on a space; however, a full HVAC design involves more than just the load estimate calculation - the load calculation is the first step of the iterative HVAC design procedure. This guide describes the equipment selection of a split system air conditioner and furnace for an example house in Chicago, IL as well as a heat pump system for an example house in Orlando, Florida. The required heating and cooling load information for the two example houses was developed in the Department of Energy Building America Strategy Guideline: Accurate Heating and Cooling Load Calculations.

Burdick, A.

2012-02-01T23:59:59.000Z

80

Porous insulation in HVAC systems  

Science Conference Proceedings (OSTI)

Porous insulation used to line the air stream surfaces of HVAC equipment provides a locus for the accumulation of dirt and debris. Dirt and debris are hydrophilic and the insulation on the air stream surfaces of mechanical cooling systems thus provides a niche for mold growth. The mold growing on porous insulation unlike moldy debris on a hard surface such as sheetmetal cannot be removed by duct cleaning. Actions for proactively preventing biocontamination of HVAC insulation include the following. (1) Porous insulation shall not be used to line the air stream surfaces of HVAC plenums where wetting is likely such as in the vicinity of cooling coils

Philip R. Morey

1995-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "liquid desiccant hvac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Design and testing a solar cooling system employing liquid desiccants: Dehumidifier experiments in Colorado State University Solar House II: Final report, 1986--1987  

DOE Green Energy (OSTI)

A nominal 3-ton (10.5-kW) lithium bromide, open-cycle desiccant cooling system has been designed, installed, and operated. This experimental system dehumidifies ambient air in a packed bed utilizing an aqueous solution of lithium bromide. The absorbent solution is distributed by spray nozzles and flows countercurrent to the air. The dilute solution exiting the dehumidifier is concentrated in a packed bed regenerator by solar heated air. The strong solution is cooled by two heat exchangers before reentering the dehumidifier. Provisions to simulate conditions of high ambient humidity and temperature have been made. Experiments on the dehumidifier operating in a decoupled mode (without countercurrent regenerator operation) have been carried out. Cooling capacities in the range of 1.0--4.0 refrigeration tons have been achieved, depending upon the operating conditions. The effect of different independent variables on the capacity of the dehumidifier has been studied. An empirical equation correlating the variables have been obtained by statistical analysis of the data. The equation obtained indicates that the capacity of the dehumidifier depends strongly on the solution concentration, solution flow rate, air inlet temperature and the air humidity. Two other variables studied, the solution inlet temperature and the air flow rate, did not affect the cooling capacity greatly. The dependence of condensation rate on each of the variables is analyzed. 22 refs., 17 figs., 3 tabs.

Lenz, T.G.; Loef, G.O.G.; Patnaik, S.

1987-12-01T23:59:59.000Z

82

Desiccant degradation in desiccant cooling systems: An experimental study  

SciTech Connect

The authors conducted experiments to quantify the effects of thermal cycling and exposure to contamination on solid desiccant materials that may be used in desiccant cooling systems. The source of contamination was cigarette smoke, which is considered one of the worst pollutants in building cooling applications. The authors exposed five different solid desiccants to ``ambient`` and ``contaminated`` humid air: silica gel, activated alumina, activated carbon, molecular sieves, and lithium chloride. They obtained the moisture capacity of samples as a function of exposure time. Compared to virgin desiccant samples, the capacity loss caused by thermal cycling with humid ambient air was 10 percent to 30 percent for all desiccants. The capacity loss because of combined effect of thermal cycling with ``smoke-filled`` humid air was between 30 percent to 70 percent. The higher losses occurred after four months of experiment time, which is equivalent to four to eight years of field operation. Using a system model and smoke degradation data on silica gel, the authors predicted that, for low-temperature regeneration, the loss in performance of a ventilation-cycle desiccant cooling system would be between 10 percent to 35 percent, in about eight years, with higher value under worst conditions.

Pesaran, A.A. [National Renewable Energy Lab., Golden, CO (United States)

1993-11-01T23:59:59.000Z

83

Classroom HVAC: Improving ventilation and saving energy -- field study plan  

E-Print Network (OSTI)

in this study. Classroom HVAC: Improving Ventilation andV8doc.sas.com/sashtml. Classroom HVAC: Improving VentilationBerkeley, CA 94720. Classroom HVAC: Improving Ventilation

Apte, Michael G.; Faulkner, David; Hodgson, Alfred T.; Sullivan, Douglas P.

2004-01-01T23:59:59.000Z

84

Inverted Attic Bulkhead for HVAC Ductwork | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Inverted Attic Bulkhead for HVAC Ductwork Inverted Attic Bulkhead for HVAC Ductwork Inverted Attic Bulkhead for HVAC Ductwork, Roseville, California (Fact Sheet), Building America...

85

HVAC component data modeling using industry foundation classes  

E-Print Network (OSTI)

HVAC Component Data Modeling Using Industry Foundationof a major extension of the HVAC part of the IFC data model.generic approach for handling HVAC components. This includes

Bazjanac, Vladimir; Forester, James; Haves, Philip; Sucic, Darko; Xu, Peng

2002-01-01T23:59:59.000Z

86

Co-simulation of innovative integrated HVAC systems in buildings  

E-Print Network (OSTI)

Integrated Simulation for HVAC Per- formance Prediction:air-conditioning equipment models (HVAC BESTEST), volume 1:air-conditioning equipment models (HVAC BESTEST), volume 2:

Trcka, Marija

2010-01-01T23:59:59.000Z

87

MODELING AND SIMULATION OF HVAC FAULTS IN ENERGYPLUS  

E-Print Network (OSTI)

Methodology for Secondary HVAC Systems, Doctoral Thesis,2002, Particulate Fouling of HVAC Heat Exchangers, Doctoraland diagnosis strategy for HVAC systems involving sensor

Basarkar, Mangesh

2013-01-01T23:59:59.000Z

88

Modeling and Measurement Constraints in Fault Diagnostics for HVAC Systems  

E-Print Network (OSTI)

in Fault Diagnostics for HVAC Systems Massieh Najafi 1 ,tools for determining HVAC diagnostics, methods todetect faults in HVAC systems are still generally

Najafi, Massieh

2010-01-01T23:59:59.000Z

89

Fault Detection and Diagnosis in Building HVAC Systems  

E-Print Network (OSTI)

Wright, “Condition monitoring in HVAC subsystems using firstmonitoring packaged HVAC equipment. ASHRAE Transactions”,Detection and Diagnosis of HVAC Systems Using Support Vector

Najafi, Massieh

2010-01-01T23:59:59.000Z

90

Method and apparatus for extracting water from air using a desiccant  

DOE Patents (OSTI)

The present invention provides a method and apparatus for extracting liquid water from moist air using minimal energy input. The method can be considered as four phases: (1) adsorbing water from air into a desiccant, (2) isolating the water-laden desiccant from the air source, (3) desorbing water as vapor from the desiccant into a chamber, and (4) isolating the desiccant from the chamber, and compressing the vapor in the chamber to form liquid condensate. The liquid condensate can be removed for use. Careful design of the dead volumes and pressure balances can minimize the energy required. The dried air can be exchanged for fresh moist air and the process repeated. An apparatus comprises a first chamber in fluid communication with a desiccant, and having ports to intake moist air and exhaust dried air. The apparatus also comprises a second chamber in fluid communication with the desiccant. The second chamber allows variable internal pressure, and has a port for removal of liquid condensate. Each chamber can be configured to be isolated or in communication with the desiccant. The first chamber can be configured to be isolated or in communication with a course of moist air. Various arrangements of valves, pistons, and chambers are described.

Spletzer, Barry L. (Albuquerque, NM); Callow, Diane Schafer (Albuquerque, NM)

2003-01-01T23:59:59.000Z

91

Review of Desiccant Dehumidification Technology  

DOE Green Energy (OSTI)

This paper overviews applications of desiccant technology for dehumidifying commercial and institutional buildings. Because of various market, policy, and regulatory factors, this technology is especially attractive for dehumidification applications in the I990s.

Pesaran, A. A.

1994-10-01T23:59:59.000Z

92

Building Energy Software Tools Directory : HVAC Residential Load...  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC Residential Load Calcs HD for the iPad Back to Tool HVAC Residential Load Calcs HD screenshot HVAC Residential Load Calcs HD screenshot HVAC Residential Load Calcs HD...

93

Desiccant contamination research: Report on the desiccant contamination test facility  

DOE Green Energy (OSTI)

The activity in the cooling systems research involves research on high performance dehumidifiers and chillers that can operate efficiently with the variable thermal outputs and delivery temperatures associated with solar collectors. It also includes work on advanced passive cooling techniques. This report describes the work conducted to improve the durability of solid desiccant dehumidifiers by investigating the causes of degradation of desiccant materials from airborne contaminants and thermal cycling. The performance of a dehumidifier strongly depends on the physical properties and durability of the desiccant material. To make durable and reliable dehumidifiers, an understanding is needed of how and to what degree the performance of a dehumidifier is affected by desiccant degradation. This report, an account of work under Cooling Systems Research, documents the efforts to design and fabricate a test facility to investigate desiccant contamination based on industry and academia recommendations. It also discusses the experimental techniques needed for obtaining high-quality data and presents plans for next year. Researchers of the Mechanical and Industrial Technology Division performed this work at the Solar Energy Research Institute in FY 1988 for DOE's Office of Solar Heat Technologies. 7 refs., 19 figs., 1 tab.

Pesaran, A.A.; Bingham, C.E.

1991-07-01T23:59:59.000Z

94

Desiccant contamination research: Report on the desiccant contamination test facility  

SciTech Connect

The activity in the cooling systems research involves research on high performance dehumidifiers and chillers that can operate efficiently with the variable thermal outputs and delivery temperatures associated with solar collectors. It also includes work on advanced passive cooling techniques. This report describes the work conducted to improve the durability of solid desiccant dehumidifiers by investigating the causes of degradation of desiccant materials from airborne contaminants and thermal cycling. The performance of a dehumidifier strongly depends on the physical properties and durability of the desiccant material. To make durable and reliable dehumidifiers, an understanding is needed of how and to what degree the performance of a dehumidifier is affected by desiccant degradation. This report, an account of work under Cooling Systems Research, documents the efforts to design and fabricate a test facility to investigate desiccant contamination based on industry and academia recommendations. It also discusses the experimental techniques needed for obtaining high-quality data and presents plans for next year. Researchers of the Mechanical and Industrial Technology Division performed this work at the Solar Energy Research Institute in FY 1988 for DOE's Office of Solar Heat Technologies. 7 refs., 19 figs., 1 tab.

Pesaran, A.A.; Bingham, C.E.

1991-07-01T23:59:59.000Z

95

Ameren Illinois (Electric) - Custom, HVAC, and Motor Business...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Custom, HVAC, and Motor Business Efficiency Incentives Ameren Illinois (Electric) - Custom, HVAC, and Motor Business Efficiency Incentives Eligibility Commercial Industrial...

96

Building HVAC Requirements Overview Page 4-1 4 Building HVAC Requirements  

E-Print Network (OSTI)

Building HVAC Requirements ­ Overview Page 4-1 4 Building HVAC Requirements 4.1 Overview 4 conditioning (HVAC) systems. The requirements are presented in this chapter so that it may serve as a single. 2008 Residential Compliance Manual August 2009 #12;Page 4-2 Building HVAC Requirements ­ Overview 4

97

Development Practice in HVAC Controls  

NLE Websites -- All DOE Office Websites (Extended Search)

Development Practice in HVAC Controls Development Practice in HVAC Controls Speaker(s): John Zhou Date: April 11, 2011 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Philip Haves The presentation will introduce development tools and design considerations used in HVAC controls development. Controls development use simulation, lab testing and field trial at different phases of the project cycle to improve control performance and to achieve rapid development. Development starts with simulation to originate and define algorithm concept. The concept is then implemented in a prototype controller, and tested in lab environment. The concept is refined and verified by analyzing lab results. In the final phase of development, controllers with refined and verified algorithms are installed in field trial sites to ensure system integration and to confirm

98

Application of Desiccant Drying in Plastic Molding  

E-Print Network (OSTI)

Desiccants are materials that have an affinity, after heating, for water vapor. Desiccant materials have long been applied in industrial processes requiring low humidity environments. A gas-fired desiccant system improved the productivity of one blowmolding process by reducing the number of defects and allowing an increase in line speed. The environmental impact of the operation improved because electrical usage did not increase incrementally and CFC usage did not change. A comparison of the efficiency of desiccant and refrigeration dehumidification is presented.

Brown, M.; Connors, G.; Moore, D.

1993-03-01T23:59:59.000Z

99

New Adsorbent Materials for Desiccant Cooling  

dehumidification systems. ... as having superior performance to the primary commercial ... The majority of desiccant dehumidification systems used for ...

100

Grundfos HVAC OEM Efficient water hydraulics  

E-Print Network (OSTI)

Grundfos HVAC OEM Efficient water hydraulics for Heat Pumps Anders Mønsted GRUNDFOS Holding A/S Group Technical Key Account Manager HVAC OEM Project Management http://net.grundfos.com/doc/webnet/hv acoem/index.htmlOEM online #12;Introduction Grundfos Company Grundfos HVAC OEM Current Circulator Range

Oak Ridge National Laboratory

Note: This page contains sample records for the topic "liquid desiccant hvac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Energirigtige pumpekoblinger i HVAC-systemer  

E-Print Network (OSTI)

Energirigtige pumpekoblinger i HVAC-systemer PSO 2003 - FORSKNING & UDVIKLING I EFFEKTIV energieffektive HVAC-aggregater #12;InformationomProjektnr.:335-021 PROCESSEN: Projektet er gennemført af en reguleringsprincipper, mens Exhausto har leveret HVAC-aggregat og knowhow inden for klimasystemer. Grundfos

102

MODELING PARTICLE DEPOSITION ON HVAC HEAT EXCHANGERS  

E-Print Network (OSTI)

LBNL-49339 MODELING PARTICLE DEPOSITION ON HVAC HEAT EXCHANGERS J.A. Siegel1,3 * and W.W. Nazaroff2 Department of Energy under contract DE-AC03-76SF00098. #12;MODELING PARTICLE DEPOSITION ON HVAC HEAT, such as discontinuities in the fins, are hypothesized to be responsible for the discrepancy. INDEX TERMS HVAC, Fouling

103

CALIFORNIA ENERGY Small HVAC Database Of Monitored  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Small HVAC Database Of Monitored Information Database of Compiled of the Integrated Design of Small Commercial HVAC Systems research project. The reports are a result of funding: Productivity and Interior Environments Integrated Design of Large Commercial HVAC Systems Integrated Design

104

CALIFORNIA ENERGY Small HVAC System Design Guide  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Small HVAC System Design Guide DESIGNGUIDELINES October 2003 500;#12;Small HVAC System Design Guide Acknowledgements i Acknowledgements The products and outcomes presented; Darren Goody, PECI, Design Guide review. #12;Small HVAC System Design Guide Preface ii Preface The Small

105

SIMULATION OF RESIDENTIAL HVAC SYSTEM PERFORMANCE  

E-Print Network (OSTI)

1 LBNL-47622 SIMULATION OF RESIDENTIAL HVAC SYSTEM PERFORMANCE Walker, I., Siegel, J ..................................................... 9 #12;3 ABSTRACT In many parts of North America residential HVAC systems are installed outside of the simulations is that they are dynamic - which accounts for cyclic losses from the HVAC system and the effect

106

PROJECT REPORT HVAC EQUIPMENT DEMOGRAPHICS AND CAPACITY  

E-Print Network (OSTI)

PROJECT REPORT HVAC EQUIPMENT DEMOGRAPHICS AND CAPACITY ANALYSIS TOOLS APPLICABLE TO MULTI Commercial HVAC Design Process 12 5.0 Conclusion 18 6.0 References 19 TABLE OF CONTENTS SECTIONS #12;MULTI performance by collectively improving the enve- lope, lighting and HVAC systems. The primary goals of the UC

California at Davis, University of

107

CALIFORNIA ENERGY Small HVAC Problems and Potential  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Small HVAC Problems and Potential Savings Reports Summary of Problems of the Integrated Design of Small Commercial HVAC Systems research project. The reports are a result of funding: Productivity and Interior Environments Integrated Design of Large Commercial HVAC Systems Integrated Design

108

Software tools for HVAC research  

Science Conference Proceedings (OSTI)

Energy saving methods can be employed to reduce energy consumption in buildings, or improve indoor thermal conditions. An example of those methods is the use of permeable coverings, but there are other important parameters like thermal inertia. To understand ... Keywords: Building, Computer, Design, Energy saving, HVAC, Software tools

José A. Orosa; Armando C. Oliveira

2011-10-01T23:59:59.000Z

109

A review of desiccant cooling systems  

SciTech Connect

This paper describes recent published design advances that have been made in desiccant cooling systems. In desiccant cooling cycles, the desiccant reduces the humidity of the air by removing moisture from the air. Then the temperature is reduced by other components such as heat exchangers, evaporative coolers, or conventional cooling coils. The main advantage that desiccant cooling systems offer is the capability of using low-grade thermal energy. Desiccant cooling systems for residential and commercial applications are now being used to reduce energy-operating costs. However, the initial costs are comparatively high. The focus of research for the past decade has been to develop desiccant systems with a high coefficient of performance. Recent studies have emphasized computer modeling and hybrid systems that combine desiccant dehumidifiers with conventional systems.

Waugaman, D.G.; Kini, A.; Kettleborough, C.F. (Texas A and M Univ., College Station (United States))

1993-03-01T23:59:59.000Z

110

Desiccant Enhanced Evaporative Air-Conditioning (DEVap): Evaluation of a New Concept in Ultra Efficient Air Conditioning  

SciTech Connect

NREL has developed the novel concept of a desiccant enhanced evaporative air conditioner (DEVap) with the objective of combining the benefits of liquid desiccant and evaporative cooling technologies into an innovative 'cooling core.' Liquid desiccant technologies have extraordinary dehumidification potential, but require an efficient cooling sink. DEVap's thermodynamic potential overcomes many shortcomings of standard refrigeration-based direct expansion cooling. DEVap decouples cooling and dehumidification performance, which results in independent temperature and humidity control. The energy input is largely switched away from electricity to low-grade thermal energy that can be sourced from fuels such as natural gas, waste heat, solar, or biofuels.

Kozubal, E.; Woods, J.; Burch, J.; Boranian, A.; Merrigan, T.

2011-01-01T23:59:59.000Z

111

STATE OF CALIFORNIA CERTIFICATE OF COMPLIANCE, PRESCRIPTIVE HVAC ALTERATIONS  

E-Print Network (OSTI)

STATE OF CALIFORNIA CERTIFICATE OF COMPLIANCE, PRESCRIPTIVE HVAC ALTERATIONS CEC-MECH-1C-ALT-HVAC (Revised 07/10) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE MECH-1C-ALT-HVAC Prescriptive HVAC Steps" column below. Note: After installation of HVAC units and/or ducts, the Installation

112

Empirical Methodologies for Improving HVAC Efficiency  

NLE Websites -- All DOE Office Websites (Extended Search)

Empirical Methodologies for Improving HVAC Efficiency Empirical Methodologies for Improving HVAC Efficiency Speaker(s): Anil Aswani Date: September 21, 2012 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Michael Wetter This talk describes the use of empirical methodologies that we have developed for the purpose of improving heating, ventilation, and air-conditioning (HVAC) efficiency through better control algorithms and configuration. We show that semiparametric regression can both identify simplified models of thermal HVAC dynamics while also estimating time-varying heating loads using only real-time temperature measurements from thermostats. These models can be used with our learning-based model predictive control (LBMPC) method in order to improve the energy-efficiency of HVAC. Experiments on testbeds with different types of HVAC show the

113

HVAC Technician | Princeton Plasma Physics Lab  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC Technician HVAC Technician Department: Facilities Supervisor(s): Tom Ward Staff: L&S 07 Requisition Number: 1300884 Under the supervision of the General Lead Technician and Lead HVAC Technician, the incumbent will be responsible for the installation, preventative maintenance, troubleshooting and repair of various HVAC and refrigeration equipment; local HVAC control systems and ancillary support equipment; and will work with other groups within the Division and throughout the Laboratory to ensure long-term, safe and efficient operation of HVAC and refrigeration systems. All tasks must be completed in a timely, cost efficient manner, support on-going sustainability initiatives and energy efficiency programs at the Laboratory. The incumbent is expected to utilize thorough theoretical knowledge and techniques to accomplish

114

Analysis of solar desiccant systems and concepts  

DOE Green Energy (OSTI)

A new approach to modeling desiccant systems has been developed. Computer programs for predicting the performance silica gel beds in single-blow situations and in cyclically operating desiccant cooling systems have been written (DESSIM). The single-blow model has been validated and shows excellent agreement with experimental data from SERI's desiccant test lab. Experimental data published by Koh are shown along with the corresponding prediction using DESSIM.

Barlow, R.

1981-05-01T23:59:59.000Z

115

Wireless Temperature Sensors for Improved HVAC Control  

NLE Websites -- All DOE Office Websites (Extended Search)

reliable, and affordable and affordable Wireless Temperature Sensors for Improved HVAC Control An assessment of wireless sensor technology Executive Summary This Technology...

116

Modeling and Identification for HVAC Systems.  

E-Print Network (OSTI)

??Heating, Ventilation and Air Conditioning (HVAC) systems consist of all the equipment that control the conditions and distribution of indoor air. Indoor air must be… (more)

Scotton, Francesco

2012-01-01T23:59:59.000Z

117

HVAC Testing, Adjusting, and Balancing Guideline  

Science Conference Proceedings (OSTI)

This report provides practical guidelines that can be used by power plant personnel to diagnose and troubleshoot heating, ventilating, and air conditioning (HVAC) system and component performance problems.

2001-10-24T23:59:59.000Z

118

Columbia Water & Light- Residential HVAC Rebate Program  

Energy.gov (U.S. Department of Energy (DOE))

Columbia Water & Light (CWL) provides an HVAC incentive for residential customers that are replacing an older heating and cooling system. Customers should submit the mechanical permit from a...

119

Particulate Fouling of HVAC Heat Exchangers Jeffrey Alexander Siegel  

E-Print Network (OSTI)

Particulate Fouling of HVAC Heat Exchangers by Jeffrey Alexander Siegel B.S. (Swarthmore College.......................................................................................xv CHAPTER 1: PARTICULATE FOULING OF HVAC HEAT EXCHANGERS ....1 1.1 Introduction.......................................................................11 CHAPTER 2: MODELING PARTICLE DEPOSITION ON HVAC HEAT EXCHANGERS

Siegel, Jeffrey

120

Building Energy Software Tools Directory: HVAC Residential Load...  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC Residential Load Calcs HD for the iPad Carmel Software logo HVAC Residential Load Calcs HD is a comprehensive HVAC heating and cooling load calculation application for the...

Note: This page contains sample records for the topic "liquid desiccant hvac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Compression effects on pressure loss in flexible HVAC ducts  

E-Print Network (OSTI)

to Determine Flow Resistance of HVAC Air Ducts and Fittings.Pressure Loss in Flexible HVAC Ducts Bass Abushakra, Ph.D.to Determine Flow Resistance of HVAC Air Ducts and Fittings.

Abushakra, Bass; Walker, Iain S.; Sherman, Max H.

2002-01-01T23:59:59.000Z

122

Fouling of HVAC fin and tube heat exchangers  

E-Print Network (OSTI)

air ? air ? part ? part FPI HVAC REFERENCES Anonymous, 1987,LBNL-47668 Fouling of HVAC Fin and Tube Heat ExchangersCIEE SPONSOR. FOULING OF HVAC FIN AND TUBE HEAT EXCHANGERS

Siegel, Jeffrey; Carey, Van P.

2001-01-01T23:59:59.000Z

123

Measuring rates of outdoor airflow into HVAC systems  

NLE Websites -- All DOE Office Websites (Extended Search)

Measuring rates of outdoor airflow into HVAC systems Title Measuring rates of outdoor airflow into HVAC systems Publication Type Journal Article LBNL Report Number LBNL-51583 Year...

124

Report on HVAC Option Selections for a Relocatable Classroom...  

NLE Websites -- All DOE Office Websites (Extended Search)

Report on HVAC Option Selections for a Relocatable Classroom Energy and Indoor Environmental Quality Field Study Title Report on HVAC Option Selections for a Relocatable Classroom...

125

HVAC Water Heater Field Tests Research Project | Department of...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC Water Heater Field Tests Research Project HVAC Water Heater Field Tests Research Project The U.S. Department of Energy is currently conducting research into heating,...

126

Modeling and Simulation of HVAC Faulty Operations and Performance...  

NLE Websites -- All DOE Office Websites (Extended Search)

Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues Title Modeling and Simulation of HVAC Faulty Operations and Performance...

127

HVAC system study: a data-driven approach.  

E-Print Network (OSTI)

?? The energy consumed by heating, ventilating, and air conditioning (HVAC) systems has increased in the past two decades. Thus, improving efficiency of HVAC systems… (more)

Xu, Guanglin

2012-01-01T23:59:59.000Z

128

Improving Relocatable Classroom HVAC For Improved IEQ And Energy...  

NLE Websites -- All DOE Office Websites (Extended Search)

Improving Relocatable Classroom HVAC For Improved IEQ And Energy Efficiency Title Improving Relocatable Classroom HVAC For Improved IEQ And Energy Efficiency Publication Type...

129

DOE Convening Report on Certification of Commercial HVAC and...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Convening Report on Certification of Commercial HVAC and CRE Products DOE Convening Report on Certification of Commercial HVAC and CRE Products This document is the convening...

130

Ventilation, temperature, and HVAC characteristics in small and...  

NLE Websites -- All DOE Office Websites (Extended Search)

Ventilation, temperature, and HVAC characteristics in small and medium commercial buildings in California Title Ventilation, temperature, and HVAC characteristics in small and...

131

Ameren Illinois (Electric) - Custom, HVAC, and Motor Business...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ameren Illinois (Electric) - Custom, HVAC, and Motor Business Efficiency Incentives Ameren Illinois (Electric) - Custom, HVAC, and Motor Business Efficiency Incentives < Back...

132

System-Level Monitoring and Diagnosis of Building HVAC System.  

E-Print Network (OSTI)

??Heating, ventilation, and air conditioning (HVAC) is an indoor environmental technology that is extensively instrumented for large-scale buildings. Among all subsystems of buildings, the HVAC… (more)

Wu, Siyu

2013-01-01T23:59:59.000Z

133

Monitoring-based HVAC Commissioning of an Existing Office Building...  

NLE Websites -- All DOE Office Websites (Extended Search)

Monitoring-based HVAC Commissioning of an Existing Office Building for Energy Efficiency Title Monitoring-based HVAC Commissioning of an Existing Office Building for Energy...

134

Chapter 5: Lighting, HVAC, and Plumbing | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

5: Lighting, HVAC, and Plumbing Chapter 5: Lighting, HVAC, and Plumbing Chapter 5 of the LANL Sustainable Design Guide with guidelines for developing sustainable, healthy,...

135

Comparison of Building Energy Modeling Programs: HVAC Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

Modeling Programs: HVAC Systems Title Comparison of Building Energy Modeling Programs: HVAC Systems Publication Type Report LBNL Report Number LBNL-6432E Year of Publication 2013...

136

Modeling and simulation of HVAC faults in EnergyPlus  

NLE Websites -- All DOE Office Websites (Extended Search)

simulation of HVAC faults in EnergyPlus Title Modeling and simulation of HVAC faults in EnergyPlus Publication Type Conference Paper Refereed Designation Refereed Year of...

137

New and Underutilized Technology: HVAC Occupancy Sensors | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC Occupancy Sensors New and Underutilized Technology: HVAC Occupancy Sensors October 4, 2013 - 4:20pm Addthis The following information outlines key deployment considerations...

138

Polymers as Advanced Materials for Desiccant Applications: 1987  

DOE Green Energy (OSTI)

This research is concerned with solid materials used as desiccants for desiccant cooling systems that process water vapor in an atmosphere to produce net cooling.

Czanderna, A. W.

1988-12-01T23:59:59.000Z

139

Luminaire/plenum/HVAC simulator  

SciTech Connect

This paper describes a new apparatus designed to model the physical parameters that affect fluorescent lamp performance under realistic operating conditions. These parameters include fixture type, mounting configuration, HVAC integration, and room air temperature, which directly determine the minimum lamp wall temperature (MLWT) and, therefore, the resulting light output of the lamp/ballast system. This apparatus is used principally to measure MLWT under operating conditions, which enables us to identify the effects the major parameters have on lamp/ballast system performance. Initial parametric results illustrate the use of this apparatus to provide representative MLWTs for a range of application conditions.

Siminovitch, M.J.; Rubinstein, F.M.; Clark, T.A.; Verderber, R.R.

1985-07-01T23:59:59.000Z

140

Commercial Building HVAC: How it Affects People  

NLE Websites -- All DOE Office Websites (Extended Search)

Commercial Building HVAC: How it Affects People Commercial Building HVAC: How it Affects People Speaker(s): William Fisk Date: November 13, 2000 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: David Faulkner Commercial building heating, ventilating, and air conditioning (HVAC) systems are designed primarily to maintain a reasonable level of thermal comfort while limiting first costs and energy consumption. However, research conducted predominately within the last decade suggests that commercial building HVAC significantly influences human outcomes other than thermal comfort, including the health, satisfaction, and work performance of the building's occupants. This presentation will review the relationships of these outcomes with HVAC system type, filtration system efficiency, indoor air temperature, and outside air ventilation rate.

Note: This page contains sample records for the topic "liquid desiccant hvac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Improvements in solid desiccant cooling  

Science Conference Proceedings (OSTI)

The DINC (Direct-Indirect Evaporative Cooling) cycle was proposed in 1986 by Texas A and M researchers. The idea was to combine the benefits of direct and indirect evaporative cooling with desiccant dehumidifying using a rotating solid silica-gel dehumidifier. Recent parametric studies completed for the Texas Energy Research in Applications Program have developed a computer design for a nominal 3-ton system that would minimize the energy consumption (both thermal and electric) while maintaining a sensible heat ratio of 75% or less. That optimum design for the original 1986 DINC cycle was modified to improve its energy efficiency. The modifications described in this paper were: (1) staging the desiccant regeneration air and (2) recirculation of the primary air to the secondary side of the indirect evaporative cooling. Computer simulations were run to study the effect of the modifications on the performance of the system. American Refrigeration Institute (AIR) standard conditions (Ambient air at 35C, 40% R.H. and Room air at 26.7C, 50% R.H.) were used for all the modifications. Results were also compared to the familiar Pennington (ventilation) cycle. The study indicated that recirculating the indirect evaporative cooler air only degenerated the performance. However, staging a portion of the regeneration air could improve the thermal coefficient of Performance by 25% over the non-staged DINC cycle. Compared to a similar staged-regeneration Pennington cycle it is a 16% improvement in thermal COP and the sensible heat ratio was 70%.

Waugaman, D.; Kini, A.; Kettleborough, C.F. (Texas A and M Univ., College Station (United States))

1993-01-01T23:59:59.000Z

142

Residential HVAC Indoor Air Quality(ASHRAE 62.2)  

E-Print Network (OSTI)

Residential HVAC && Indoor Air Quality(ASHRAE 62.2) Tav Commins #12;Contact Information · Energy construction, Additions /Alterations · Nonresidential and Residential #12;Residential HVAC && Indoor Air Quality(ASHRAE 62.2) ·HVAC EfficiencyHVAC Efficiency ·Quality Installation (HERS Measures) S li b HERS R t

143

2013 Energy Code Changes That Effect the HVAC  

E-Print Network (OSTI)

2013 Energy Code Changes That Effect the HVAC Industry Tav Commins Mechanical Engineer California Energy Commission #12;HVAC Mandatory Measures For All Newly Installed Residential HVAC Systems (New Watt Draw at .58 W/CFM, or (return duct and filter sizing) MERV 6 Filter #12;Residential HVAC Measures

California at Davis, University of

144

CALIFORNIA ENERGY Large HVAC Field and Baseline Data  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Large HVAC Field and Baseline Data Field Data Collection: Site Survey of the Integrated Design of Large Commercial HVAC Systems research project. The reports are a result of funding Design of Large Commercial HVAC Systems Integrated Design of Small Commercial HVAC Systems Integrated

145

Experiments on sorption hysteresis of desiccant materials  

DOE Green Energy (OSTI)

Solid desiccant cooling systems take advantage of solar energy for air conditioning. The process involves passing air through a desiccant bed for drying and subsequent evaporative cooling to provide the air conditioning. The desiccant is then regenerated with hot air provided by a gas burner or solar collectors. This performance is limited by the capacity of the desiccant, its sorption properties, and the long-term stability of the desiccant material under cyclic operation conditions. Therefore, we have developed a versatile test facility to measure the sorption properties of candidate solid desiccant materials under dynamic conditions, under different geometrical configurations, and under a broad range of process air stream conditions, characteristic of desiccant dehumidifer operation. We identified a dependence of the sorption processes on air velocity and the test cell aspect ratio and the dynamic hysteresis between adsorption and desorption processes. These experiments were geared to provide data on the dynamic performance of silica gel in a parallel-passage configuration to prepare for tests with a rotary dehumidifier that will be conducted at SERI in late FY 1984. We also recommend improving the accuracy of the isotopic perturbation technique.

Pesaran, A.; Zangrando, F.

1984-08-01T23:59:59.000Z

146

Optimization Control Strategies for HVAC Terminal Boxes  

E-Print Network (OSTI)

The HVAC terminal boxes are one of the major building HVAC components. They directly impact the building room comfort conditions and the energy costs. How to operate the box in a highly energy efficient way and maintain the room comfort level is an important topic in today's building energy management and HVAC control field. The authors developed novel optimized control strategies and operation schedules for the terminal boxes for both occupied and non-occupied hours. The optimized control schedules were implemented in a medical complex during the commissioning. This not only improved the building comfort conditions but also reduced the energy costs.

Zhu, Y.; Batten, T.; Noboa, H.; Claridge, D. E.; Turner, W. D.; Liu, M.; Zhou, J.; Cameron, C.; Keeble, D.; Hirchak, R.

2000-01-01T23:59:59.000Z

147

Salsbury and Diamond: Automated Testing of HVAC Systems for Commissioning -1 -Automated Testing of HVAC Systems for Commissioning  

E-Print Network (OSTI)

and Diamond: Automated Testing of HVAC Systems for Commissioning - 1 - Automated Testing of HVAC Systems This paper describes an approach to the automation of the commissioning of HVAC systems. The approach of many HVAC systems is limited more by poor installation, commissioning, and maintenance than by poor

148

Facilities for testing desiccant materials and geometries of dehumidifiers for solar-regenerated desiccant cooling systems  

SciTech Connect

Four experimental test facilities for characterizing the performance of solid desiccant materials and dehumidifier matrices which have the potential to be used in solar-regenerated desiccant cooling systems are reviewed. The water equilibrium capacity and sorption rates of desiccant materials, depending on their form, can be either measured with a quartz crystal microbalance or a desiccant sorption test facility. Pressure drop, heat- and mass-transfer rates and transient equilibrium dehumidification capacity of a dehumidifier matrices are measured in a desiccant heat and mass transfer test facility. The performance and steady state dehumidification capabilities of prototype dehumidifier components under realistic conditions are measured in a desiccant cyclic test facility. The description of the test apparatus, experimental procedure, measurement errors, and typical results for the four test facilities are presented here. 15 refs., 9 figs., 1 tab.

Pesaran, A.A.; Bingham, C.E.

1988-12-01T23:59:59.000Z

149

Underground-desiccant cooling system  

DOE Green Energy (OSTI)

The Underground-Desiccant Cooling System relies on the successful coordination of various components. The central feature of the system is a bed of silica gel which will absorb moisture from house air until the gel has become saturated. When this point has been reached, the silica gel must be regenerated by passing hot air through it. For this project, the hot air is produced by air-type solar collectors mounted on the roof and connected with the main air-handling system by means of ducts attached to the outside of the house. As the air is dehumidified its temperature is raised somewhat by the change of state. The dried but somewhat heated air, after leaving the silica gel bed, passes through a rock bin storage area and then past a water coil chiller before being circulated through the house by means of the previously existing ductwork. The cooling medium for both the rock bin and the chiller coil is water which circulates through underground pipes buried beneath the back yard at a depth of about 10 to 12 ft. When the silica gel is being regenerated by the solar collectors, house air bypasses the desiccant bed but still passes through the rock bin and the chiller coil and is cooled continuously. The system is designed for maximum flexibility so that full use can be made of the solar collectors. Ducting is arranged so that the collectors provide heat for the house in the winter and there is also a hot-water capability year-round.

Finney, O.

1982-10-01T23:59:59.000Z

150

Best Practices for Energy Efficient Cleanrooms Efficient HVAC Systems: Variable-Speed-Drive Chillers  

E-Print Network (OSTI)

resource/24/ ASHRAE handbook – HVAC systems and equipments.Efficient Cleanrooms Efficient HVAC Systems: Variable-Speed-Efficient Cleanrooms Efficient HVAC Water Systems: Variable-

Xu, Tengfang

2005-01-01T23:59:59.000Z

151

Laboratory measurement of secondary pollutant yields from ozone reaction with HVAC filters.  

E-Print Network (OSTI)

from Ozone Reaction with HVAC Filters Hugo Destaillats,from Ozone Reaction with HVAC Filters Hugo Destaillatsfrom Ozone Reaction with HVAC Filters Hugo Destaillats

Destaillats, Hugo

2012-01-01T23:59:59.000Z

152

Case study field evaluation of a systems approach to retrofitting a residential HVAC system  

E-Print Network (OSTI)

Practices for Residential HVAC Systems”. Boston, MA. Jump,techniques for measuring HVAC grille air flows". ASHRAEPractices Guide for Residential HVAC Retrofits. LBNL 53592.

Walker, Iain S.; McWiliams, Jennifer A.; Konopacki, Steven J.

2003-01-01T23:59:59.000Z

153

Home Energy Article: A Systems Approach to Retrofitting Residential HVAC Systems  

E-Print Network (OSTI)

to Retrofitting a Residential HVAC System, Lawrence Berkeleyducts. New downsized ducts and HVAC equipment. The ducts areto Retrofitting Residential HVAC Systems J.A. McWilliams and

McWilliams, Jennifer A.; Walker, Iain S.

2005-01-01T23:59:59.000Z

154

Model Predictive Control of HVAC Systems: Implementation and Testing at the University of California, Merced  

E-Print Network (OSTI)

Model Predictive Control of HVAC Systems:    Implementation and  air  conditioning  (HVAC)  account  for  27%  of  the reduction potential of HVAC systems with  active thermal 

Haves, Phillip

2010-01-01T23:59:59.000Z

155

An implementation of co-simulation for performance prediction of innovative integrated HVAC systems in buildings  

E-Print Network (OSTI)

and Judkoff, R. 2002. IEA HVAC BESTEST volume 1, Technicaland Judkoff, R. 2004. IEA HVAC BESTEST volume 2, TechnicalOF INNOVATIVE INTEGRATED HVAC SYSTEMS IN BUILDINGS Marija

Trcka, Marija

2010-01-01T23:59:59.000Z

156

Comparisons of HVAC Simulations between EnergyPlus and DOE-2.2 for Data Centers  

E-Print Network (OSTI)

ABORATORY Comparisons of HVAC Simulations between EnergyPlusemployer. Comparisons of HVAC Simulations between EnergyPlusThis paper compares HVAC simulations between EnergyPlus and

Hong, Tianzhen

2009-01-01T23:59:59.000Z

157

Improving Indoor Environmental Quality And Energy Performance Of Modular Classroom HVAC Systems  

E-Print Network (OSTI)

Schools (CHPS). 2002. "HVAC Best Practices Manual." CHPSOF MODULAR CLASSROOM HVAC SYSTEMS Michael G. APTE Ph.D. MPHRelocatable Classroom HVAC for Improved IEQ and Energy

Apte, Michael G.; Spears, Michael; Lai, Chi-Ming; Shendell, Derek G.

2005-01-01T23:59:59.000Z

158

Investigation of IAQ-Relevant Surface Chemistry and Emissions on HVAC Filter Materials  

E-Print Network (OSTI)

VOCs emitted by reactions of HVAC filters with ozone usingChemistry and Emissions on HVAC Filter Materials HugoChemistry and Emissions on HVAC Filter Materials Authors:

Destaillats, Hugo

2010-01-01T23:59:59.000Z

159

HVAC Modeling for Cost of Ownership Assessment in Biotechnology & Drugs Manufacturing  

E-Print Network (OSTI)

2000 Broomes, Peter. , “HVAC Modeling for Cost of Ownership2000 Broomes, Peter. , “HVAC Results Comparison”, April,HVAC Modeling for Cost of Ownership Assessment in

Broomes, Peter; Dornfeld, David A

2003-01-01T23:59:59.000Z

160

HVAC Equipment Rebate Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC Equipment Rebate Program HVAC Equipment Rebate Program HVAC Equipment Rebate Program < Back Eligibility Agricultural Commercial Industrial Installer/Contractor Institutional Multi-Family Residential Nonprofit Schools Savings Category Heating & Cooling Commercial Heating & Cooling Heating Cooling Heat Pumps Maximum Rebate Rebates of greater than $5,000 require pre-approval Program Info Funding Source Efficiency Vermont Public Benefit Fund Expiration Date 06/30/2013 State Vermont Program Type State Rebate Program Rebate Amount Varies depending on technology and efficiency Provider Efficiency Vermont NOTE: Rebate reservations are required for all boiler and furnace projects. Efficiency Vermont offers rebates for commercial installations of high-efficiency HVAC equipment and controls. For businesses and purchases

Note: This page contains sample records for the topic "liquid desiccant hvac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

BS-8: HVAC Modeling and Simulation  

NLE Websites -- All DOE Office Websites (Extended Search)

BS-8: HVAC Modeling and Simulation BS-8: HVAC Modeling and Simulation Speaker(s): Darko Sucic Date: December 5, 2001 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Satkartar K. Kinney Industry Foundation Classes (IFC), an object data model of buildings, are being developed by the International Alliance for Interoperability (IAI) to support data sharing and exchange in the building and construction industry. The IAI, founded in 1995, has published four releases of IFC so far. Several prototype implementations by leading software companies show that commercial IFC software is beginning to meet end user expectations of interoperability in the industry. BS-8 is an LBNL project that started last summer. It is developing the IFC HVAC extension schemata that will extend the IFC object data model and support the exchange of HVAC information

162

HVAC Energy Recovery Design and Economic Evaluation  

E-Print Network (OSTI)

ENRECO has prepared this paper on HVAC energy recovery to provide the engineer with an overview of the design engineering as well as the economic analysis considerations necessary to evaluate the potential benefits of energy recovery.

Kinnier, R. J.

1979-01-01T23:59:59.000Z

163

Modeling and optimization of building HVAC systems.  

E-Print Network (OSTI)

??This thesis presents the development of hybrid modeling methodologies for HVAC component static/steady-state models and dynamic/transient models, and the development and implementation of a model-based… (more)

Jin, Guang Yu.

2012-01-01T23:59:59.000Z

164

Wireless Demand Response Controls for HVAC  

NLE Websites -- All DOE Office Websites (Extended Search)

Wireless Demand Response Controls for HVAC Speaker(s): Clifford Federspiel Date: June 22, 2006 - 12:00pm Location: 90-3148 Seminar HostPoint of Contact: Richard Diamond Peng Xu We...

165

Modeling particle deposition on HVAC heat exchangers  

E-Print Network (OSTI)

DEPOSITION ON HVAC HEAT EXCHANGERS JA Siegel 1,3 * and WWof fin-and-tube heat exchangers by particle deposition leadsparticle deposition on heat exchanger surfaces. We present a

Siegel, J.A.; Nazaroff, W.W.

2002-01-01T23:59:59.000Z

166

HVAC Fans and Dampers Maintenance Guide  

Science Conference Proceedings (OSTI)

Heating, ventilation, and air conditioning (HVAC) systems serve an important function in nuclear power plants because these systems are responsible for maintaining many environmental conditions throughout the facility. Failure of these components can induce undesirable radiological conditions and stressful working conditions, and can compromise the life of qualified equipment. Some HVAC fan and damper failures are preventable by monitoring operating parameters and performing recommended maintenance activ...

1999-08-26T23:59:59.000Z

167

Building Technologies Office: HVAC Optimized Heat Exchangers Research  

NLE Websites -- All DOE Office Websites (Extended Search)

Optimized Heat Optimized Heat Exchangers Research Project to someone by E-mail Share Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on Facebook Tweet about Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on Twitter Bookmark Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on Google Bookmark Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on Delicious Rank Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on Digg Find More places to share Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on AddThis.com... About Take Action to Save Energy Partner with DOE Activities Appliances Research Building Envelope Research

168

Iowa Powder Atomization Technologies, Inc. | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7AC Technologies, Inc. National Renewable Energy Laboratory 498 likes 7AC Technologies, based in Woburn, Massachusetts, is developing Liquid Desiccant HVAC systems for Commercial...

169

Integrated Dynamic Electron Solutions, Inc. | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7AC Technologies, Inc. National Renewable Energy Laboratory 498 likes 7AC Technologies, based in Woburn, Massachusetts, is developing Liquid Desiccant HVAC systems for Commercial...

170

Desiccant-Based Combined Systems: Integrated Active Desiccant Rooftop Hybrid System Development and Testing Final Report- Phase 4  

SciTech Connect

This report summarizes the results of a research and development (R&D) program to design and optimize an active desiccant-vapor compression hybrid rooftop system. The primary objective was to combine the strengths of both technologies to produce a compact, high-performing, energy-efficient system that could accommodate any percentage of outdoor air and deliver essentially any required combination of temperature and humidity, or sensible heat ratio (SHR). In doing so, such a product would address the significant challenges imposed on the performance capabilities of conventional packaged rooftop equipment by standards 62 and 90.1 of the American Society of Heating, Refrigerating and Air-Conditioning Engineers. The body of work completed as part of this program built upon previous R&D efforts supported by the U.S. Department of Energy and summarized by the Phase 3b report ''Active Desiccant Dehumidification Module Integration with Rooftop Packaged HVAC Units'' (Fischer and Sand 2002), in addition to Fischer, Hallstrom, and Sand 2000; Fischer 2000; and Fischer and Sand 2004. All initial design objectives established for this development program were successfully achieved. The performance flexibility desired was accomplished by a down-sized active desiccant wheel that processes only a portion of the supply airflow, which is pre-conditioned by a novel vapor compression cycle. Variable-speed compressors are used to deliver the capacity control required by a system handling a high percentage of outdoor air. An integrated direct digital control system allows for control capabilities not generally offered by conventional packaged rooftop systems. A 3000-cfm prototype system was constructed and tested in the SEMCO engineering test laboratory in Columbia, MO, and was found to operate in an energy-efficient fashion relative to more conventional systems. Most important, the system offered the capability to independently control the supply air temperature and humidity content to provide individual sensible and latent loads required by an occupied space without over-cooling and reheating air. The product was developed using a housing construction similar to that of a conventional packaged rooftop unit. The resulting integrated active desiccant rooftop (IADR) is similar in size to a currently available conventional rooftop unit sized to provide an equivalent total cooling capacity. Unlike a conventional rooftop unit, the IADR can be operated as a dedicated outdoor air system processing 100% outdoor air, as well as a total conditioning system capable of handling any ratio of return air to outdoor air. As part of this R&D program, a detailed investigation compared the first cost and operating cost of the IADR with costs for a conventional packaged approach for an office building located in Jefferson City, MO. The results of this comparison suggest that the IADR approach, once commercialized, could be cost-competitive with existing technology--exhibiting a one-year to two-year payback period--while simultaneously offering improved humidity control, indoor air quality, and energy efficiency.

Fischer, J

2005-05-06T23:59:59.000Z

171

Advanced Open-Cycle Desiccant Cooling System  

E-Print Network (OSTI)

The concept of staged regeneration as means of improving the desiccant cooling system performance is the subject of investigation in this study. In the staged regeneration, the regeneration section of desiccant dehumidifier is divided into two parts and only the latter fraction is subjected to the desorption air stream which has been heated to the desired regeneration temperature. In the present work, the mathematical model describing the heat and mass transfer processes that occur during sorption of moisture in the desiccnnt dehumidifier includes both the gas-side (film) and solid-side resistances for heat and mass transports. The moisture diffusion in the desiccant material is expressed by gas-phase diffusion and surface diffusion. Effects of several parameters on the performance of desiccant cooling system with staged regeneration are investigated and the results of present model are compared with those of the lumped-resistance model. Results of this study show that coefficient of perfomnnce of the desiccant cooling system can be substantially improved by using the staged regeneration concept. There is an optimum stage fraction and optimum cycle time for given system parmeters and operating conditions. The results also indicate that the cooling system performance is higher than that predicted by the lumped-resistance model.

Ko, Y. J.; Charoensupaya, D.; Lavan, Z.

1989-01-01T23:59:59.000Z

172

Building Technologies Office: HVAC and Water Heater Field Tests Research  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC and Water Heater HVAC and Water Heater Field Tests Research Project to someone by E-mail Share Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Facebook Tweet about Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Twitter Bookmark Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Google Bookmark Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Delicious Rank Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Digg Find More places to share Building Technologies Office: HVAC and Water Heater Field Tests Research Project on AddThis.com... About Take Action to Save Energy Partner with DOE Activities Appliances Research

173

Building Technologies Office: Recovery Act-Funded HVAC Research Projects  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC Research Projects to someone by E-mail HVAC Research Projects to someone by E-mail Share Building Technologies Office: Recovery Act-Funded HVAC Research Projects on Facebook Tweet about Building Technologies Office: Recovery Act-Funded HVAC Research Projects on Twitter Bookmark Building Technologies Office: Recovery Act-Funded HVAC Research Projects on Google Bookmark Building Technologies Office: Recovery Act-Funded HVAC Research Projects on Delicious Rank Building Technologies Office: Recovery Act-Funded HVAC Research Projects on Digg Find More places to share Building Technologies Office: Recovery Act-Funded HVAC Research Projects on AddThis.com... About Take Action to Save Energy Partner with DOE Activities Appliances Research Building Envelope Research Windows, Skylights, & Doors Research Space Heating & Cooling Research

174

Mapping Hvac Systems for Simulation In EnergyPlus  

NLE Websites -- All DOE Office Websites (Extended Search)

Mapping Hvac Systems for Simulation In EnergyPlus Title Mapping Hvac Systems for Simulation In EnergyPlus Publication Type Conference Paper LBNL Report Number LBNL-5565E Year of...

175

Recovery Act-Funded HVAC projects | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC projects Recovery Act-Funded HVAC projects The U.S. Department of Energy was allocated funding from the American Recovery and Reinvestment Act to conduct research into...

176

Issue #3: HVAC Proper Installation Energy Savings: Over-Promising...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3: HVAC Proper Installation Energy Savings: Over-Promising or Under-Delivering? Issue 3: HVAC Proper Installation Energy Savings: Over-Promising or Under-Delivering? What energy...

177

Modeling and simulation of HVAC Results in EnergyPlus  

NLE Websites -- All DOE Office Websites (Extended Search)

Modeling and simulation of HVAC Results in EnergyPlus Title Modeling and simulation of HVAC Results in EnergyPlus Publication Type Journal Article LBNL Report Number LBNL-5564E...

178

Decentralized nonlinear adaptive control of an HVAC system  

Science Conference Proceedings (OSTI)

This paper presents a new decentralized nonlinear adaptive controller (DNAC) for a heating, ventilating, and air conditioning (HVAC) system capable of maintaining comfortable conditions under varying thermal loads. In this scheme, an HVAC system is considered ...

Zhang Huaguang; Lilong Cai

2002-11-01T23:59:59.000Z

179

Fouling of HVAC fin and tube heat exchangers  

E-Print Network (OSTI)

Methods to Maintain Heat Exchanger Coil Cleanliness, ASHRAEof HVAC Fin and Tube Heat Exchangers Jeffrey Siegel and VanOF HVAC FIN AND TUBE HEAT EXCHANGERS Jeffrey Siegel 1,2 and

Siegel, Jeffrey; Carey, Van P.

2001-01-01T23:59:59.000Z

180

Parametric Analysis of a Solar Desiccant Cooling System using...  

NLE Websites -- All DOE Office Websites (Extended Search)

Parametric Analysis of a Solar Desiccant Cooling System using the SimSPARK Environment Title Parametric Analysis of a Solar Desiccant Cooling System using the SimSPARK Environment...

Note: This page contains sample records for the topic "liquid desiccant hvac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Chapter 5: Lighting, HVAC, and Plumbing  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

: Lighting, : Lighting, HVAC, and Plumbing High-Performance Engineering Design Lighting System Design Mechanical System Design Central Plant Systems Plumbing and Water Use Building Control Systems Electrical Power Systems Metering LANL | Chapter 5 High-Performance Engineering Design Lighting, HVAC, and Plumbing By now, the building envelope serves multiple roles. It protects the occupants from changing weather condi- tions and it plays a key part in meeting the occupants' comfort needs. The heating, ventilating, air-conditioning, and lighting (HVAC&L) systems complement the archi- tectural design, govern the building's operation and maintenance costs, and shape the building's long-term environmental impact. The architectural design maximizes the potential for a high-performance building, but it is the

182

Simulation and Optimization of HVAC Systems  

E-Print Network (OSTI)

We developed a mathematical model of a simple Heating, Ventilation and Air Conditioning (HVAC) system and implemented the model using the VisSim simulation language. We used Fourier methods to approximate (and simplify) temperature and humidity data for the model. We created an objective function to be minimized which recorded the cost of running this HVAC system. We studied different methods for minimizing the cost function, including direct search methods using VisSim and completed preliminary studies of a Dynamic Programming programming approach to simplify the optimization problem. ii Contents 0 Executive Summary 1 1 Introduction 2 2 Evaluation of Simulation Packages 3 3 Simple Room Model for an HVAC System 5 3.1 Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 3.2 Room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 3.3 Splitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 3.4 Mixer . . . ....

Ane Coughlin; George D. Ellington; Ellen Phifer; Brian Rieksts

1998-01-01T23:59:59.000Z

183

Indoor Air Quality Impacts of Residential HVAC Systems ...  

Science Conference Proceedings (OSTI)

Page 1. NISTIR 5559 Indoor Air Quality Impacts of Residential HVAC Systems Phase 11.AReport: Baseline and Preliminary Simulations ...

1997-09-03T23:59:59.000Z

184

A PDI for your HVAC System  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

8/3/2012 Technical Approach Develop a PDI for HVAC PDI focus is on Inspecting Installation - a $10 Chinese sweatshop t-shirt gets a QA/QC sticker, why not a $10k HVAC system? Develop & require diagnostics that confirm good installations: - Air flow, duct leakage, refrigerant charge, delivered temperatures, system pressures, filter requirements, fan power, noise - On board diagnostics (OBD) for flow, pressures, fan power, charge Make it a warranty requirement, code requirement, permit requirement, etc. Recommended Guidance Develop the PDI checklist and label (include target and system test results) - External Tests: duct leaks - Internal Tests: OBD for system pressures, air flow, charge, fan power - Labels: Certify tight equipment

185

HVAC Room Temperature Prediction Control Based on Neural Network Model  

Science Conference Proceedings (OSTI)

HVAC (Heating Ventilating &Air-conditioning) system is a nonlinear complex system with delay. It is very difficult to build a mathematical model of HVAC and implement model-based control. Since a BP (Back Propagation) neural network can fully approximate ... Keywords: BP neural network, predictive control, HVAC, least squares method

Shujiang Li, Shuang Ren, Xiangdong Wang

2013-01-01T23:59:59.000Z

186

Handover Performance of HVAC Duct Based Indoor Wireless Networks  

E-Print Network (OSTI)

Handover Performance of HVAC Duct Based Indoor Wireless Networks A. E. Xhafa, P. Sonthikorn, and O in indoor wireless net- works (IWN) that use heating, ventilation, and air conditioning (HVAC) ducts.e., new call blocking and handover dropping probabilities, of an IWN that uses HVAC ducts are up to 6

Stancil, Daniel D.

187

Monitoring-based HVAC Commissioning of an Existing Office  

E-Print Network (OSTI)

LBNL-5940E Monitoring-based HVAC Commissioning of an Existing Office Building for Energy Efficiency thereof or The Regents of the University of California. #12;1 Monitoring-based HVAC Commissioning@lbl.gov, Tel: 1-510-486-4921 Abstract The performance of Heating, Ventilation and Air Conditioning (HVAC

188

Utilizing Passive Ventilation to Complement HVAC Systems in Enclosed Buildings  

E-Print Network (OSTI)

Utilizing Passive Ventilation to Complement HVAC Systems in Enclosed Buildings Tom Rogg REU Student to assist HVAC has the potential to significantly reduce life cycle cost and energy consumption and electrical system that will tie thermostats to controlled valves in the actual HVAC system. Based on results

Mountziaris, T. J.

189

Long Range Passive UHF RFID System Using HVAC Ducts  

E-Print Network (OSTI)

INVITED P A P E R Long Range Passive UHF RFID System Using HVAC Ducts To provide a potential communications channel, HVAC ducts can function as electromagnetic waveguides; a 30-m read range has been-conditioning (HVAC) ducts as a potential communication channel between passive ultrahigh-frequency (UHF) radio

Hochberg, Michael

190

Atmospheric Environment 41 (2007) 31513160 Ozone removal by HVAC filters  

E-Print Network (OSTI)

Atmospheric Environment 41 (2007) 3151­3160 Ozone removal by HVAC filters P. Zhao, J.A. Siegel�, R May 2006; accepted 14 June 2006 Abstract Residential and commercial HVAC filters that have been loaded of the relative importance of HVAC filters as a removal mechanism for ozone in residential and commercial

Siegel, Jeffrey

191

An update on acoustics designs for HVAC (Engineering) K. Marriott  

E-Print Network (OSTI)

An update on acoustics designs for HVAC (Engineering) K. Marriott IOA, 29a Ashburton Road, Croydon and Air Conditioning (HVAC) engineer is to engineer ways for keeping these factors under control the HVAC engineer's environmental requirements while minimizing noise generated in the process considering

Paris-Sud XI, Université de

192

Deposition of Biological Aerosols on HVAC Heat Exchangers  

E-Print Network (OSTI)

LBNL-47669 Deposition of Biological Aerosols on HVAC Heat Exchangers Jeffrey Siegel and Iain Walker of Biological Aerosols on HVAC Heat Exchangers Jeffrey A. Siegel Iain S. Walker, Ph.D. ASHRAE Student Member that are found in commercial and residential HVAC systems of 1 - 6 m/s (200 - 1200 ft/min), particle diameters

193

MATERIALS AND INFORMATION FLOWS FOR HVAC DUCTWORK FABRICATION AND SITE  

E-Print Network (OSTI)

MATERIALS AND INFORMATION FLOWS FOR HVAC DUCTWORK FABRICATION AND SITE INSTALLATION Matt Holzemer,1, and air-conditioning (HVAC) systems requires a set of complex activities and handoffs between multiple architecture-, engineering-, and construction practitioners. This paper highlights one part of the HVAC

Tommelein, Iris D.

194

Department of Mechanical Engineering Spring 2012 HVAC Filter Sensor -Global  

E-Print Network (OSTI)

PENNSTATE Department of Mechanical Engineering Spring 2012 HVAC Filter Sensor - Global Overview The purpose of this project is to develop a heating, ventilation, and air conditioning (HVAC) monitoring a residential, forced flow, multi-zone HVAC filter needs to be replaced, and then alerts the users

Demirel, Melik C.

195

SMUD's HVAC Programs Ravi Patel-Program Planning  

E-Print Network (OSTI)

1 SMUD's HVAC Programs 5-7-13 Ravi Patel- Program Planning Bruce Baccei- R&D #12;SMUD's Residential contractors trained and BPI certified ­ Majority were pushing only HVAC; now driving the HPP · Program encourages more HVAC replacements to occur through HPP ­ Move away from stand alone programs ­ Start

California at Davis, University of

196

Continued on next page A letter explaining the 2005 HVAC  

E-Print Network (OSTI)

Continued on next page A letter explaining the 2005 HVAC Change-out to consumers is available this bulletin, or downloaded from the 2005 HVAC Change out Information website at: www.energy.ca.gov/title24 duct sealing requirements for HVAC change-outs in existing homes become effective October 1, 2005

197

Proceedings: Indoor Air 2005 OZONE REMOVAL BY RESIDENTIAL HVAC FILTERS  

E-Print Network (OSTI)

Proceedings: Indoor Air 2005 2366 OZONE REMOVAL BY RESIDENTIAL HVAC FILTERS P Zhao1,2 , JA Siegel1, Austin, Texas 78758, USA ABSTRACT HVAC filters have a significant influence on indoor air quality% for Filter #2 at a face velocity of 0.81 cm/s. The potential for HVAC filters to affect ozone concentrations

Siegel, Jeffrey

198

Occupancy Based Demand Response HVAC Control Strategy Varick L. Erickson  

E-Print Network (OSTI)

proposes an HVAC control strategy based on occupancy prediction and real time occupancy monitoring via simulation model. We dis- cuss the building parameters and the HVAC control strate- gies used for the energyOccupancy Based Demand Response HVAC Control Strategy Varick L. Erickson University of California

Cerpa, Alberto E.

199

Solar air conditioning system using desiccant wheel technology  

Science Conference Proceedings (OSTI)

The electrical energy consumption in Malaysia has increased sharply in the past few years. Modern energy efficient technologies are desperately needed for the national energy policy. In this paper, a new design of desiccant cooling is being developed ... Keywords: air-conditioning, desiccant cooling, solar thermal energy, solid desiccant

Arfidian Rachman; Sohif Mat; Taib Iskandar; M. Yahya; Azami Zaharim; Kamaruzzaman Sopian

2010-10-01T23:59:59.000Z

200

Experiments on sorption characteristics of solid desiccant materials for solar desiccant cooling systems  

DOE Green Energy (OSTI)

A test facility for measuring the sorption properties of candidate solid desiccant materials under dynamic conditions as well as equilibrium conditions, those experienced during desiccant dehumidifier operation, was constructed and tested. The theory of perturbation chromatography was initially used to measure the equilibrium properties of a desiccant/water-vapor system for the first time. Silica gel, molecular sieve, and gamma-manganese dioxide were tested. The equilibrium capacity estimated by the perturbation chromatography was lower than those available in literature, which suggests that perturbation chromatography may not be applicable to desiccant/water-vapor systems. The perturbation chromatography was replaced with a gravimetric technique, and satisfactory results were obtained for a water-vapor/molecular-sieve system.

Pesaran, A.A.

1984-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "liquid desiccant hvac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Occupancy based demand response HVAC control strategy  

Science Conference Proceedings (OSTI)

Heating, cooling and ventilation accounts for 30% energy usage and for 50% of the electricity usage in the United States. Currently, most modern buildings still condition rooms assuming maximum occupancy rather than actual usage. As a result, rooms are ... Keywords: HVAC, demand response, energy savings, occupancy, ventilation

Varick L. Erickson; Alberto E. Cerpa

2010-11-01T23:59:59.000Z

202

Randomized Model Predictive Control for HVAC Systems  

Science Conference Proceedings (OSTI)

Heating, Ventilation and Air Conditioning (HVAC) systems play a fundamental role in maintaining acceptable thermal comfort and Indoor Air Quality (IAQ) levels, essentials for occupants well-being. Since performing this task implies high energy requirements, ... Keywords: Copulas, Learning, Randomized Model Predictive Control, Smart Buildings, Sustainable Control Systems

Alessandra Parisio, Damiano Varagnolo, Daniel Risberg, Giorgio Pattarello, Marco Molinari, Karl H. Johansson

2013-11-01T23:59:59.000Z

203

Polymers as advanced materials for desiccant applications  

DOE Green Energy (OSTI)

This research is concerned with solid materials used as desiccants for desiccant cooling systems (DCSs) that process water vapor in an atmosphere to produce cooling. Background information includes an introduction to DCSs and the role of the desiccant as a system component. The water vapor sorption performance criteria used for screening the modified polymers prepared include the water sorption capacity from 5% to 80% relative humidity (R.H.), isotherm shape, and rate of adsorption and desorption. Measurements are presented for the sorption performance of modified polymeric advanced desiccant materials with the quartz crystal microbalance. Isotherms of polystyrene sulfonic acid (PSSA) taken over a 5-month period show that the material has a dramatic loss in capacity and that the isotherm shape is time dependent. The adsorption and desorption kinetics for PSSA and all the ionic salts of it studied are easily fast enough for commercial DCS applications with a wheel rotation speed of 6 min per revolution. Future activities for the project are addressed, and a 5-year summary of the project is included as Appendix A. 34 refs., 20 figs., 3 tabs.

Czanderna, A.W.

1990-12-01T23:59:59.000Z

204

Desiccant cooling using unglazed transpired solar collectors  

DOE Green Energy (OSTI)

The use of unglazed solar collectors for desiccant regeneration in a solid desiccant cooling cycle was investigated because these collectors are lower in cost than conventional glazed flat-plate collectors. Using computer models, the performance of a desiccant cooling ventilation cycle integrated with either unglazed transpired collectors or conventional glazed flat-plate collectors was obtained. We found that the thermal performance of the unglazed system was lower than the thermal performance of the glazed system because the unglazed system could not take advantage of the heat of adsorption released during the dehumidification process. For a 3-ton cooling system, although the area required for the unglazed collector was 69% more than that required for the glazed collector, the cost of the unglazed collector array was 44% less than the cost of the glazed collector array. The simple payback period of the unglazed system was half of the payback period of the glazed collector when compared to an equivalent gas-fired system. Although the use of unglazed transpired collectors makes economic sense, some practical considerations may limit their use in desiccant regeneration. 8 refs.

Pesaran, A.A. [National Renewable Energy Lab., Golden, CO (United States); Wipke, K. [Stanford Univ., CA (United States)

1992-05-01T23:59:59.000Z

205

Performance of cross-cooled desiccant dehumidifiers  

DOE Green Energy (OSTI)

A cross-cooled silica gel desiccant dehumidifier model was designed, built and tested. The performance of the unit was studied as a function of inlet process stream dew point, process stream and cooling stream flowrates and regeneration stream temperature and dew point. The tests were also simulated by a computer program and were compared to the experimental results.

Mei, V.C.; Lavan, Z.

1980-01-01T23:59:59.000Z

206

Real-Time Measurement of Rates of Outdoor Airflow into HVAC Systems: A Field Study of Three Technologies  

E-Print Network (OSTI)

to determine flow resistance of HVAC ducts and fittings.W. 2003. Outdoor airflow into HVAC systems: an evaluation ofof outdoor airflow into HVAC systems. Lawrence Berkeley

Fisk, William J.; Sullivan, Douglas P.; Faulkner, David

2005-01-01T23:59:59.000Z

207

Desiccant cooling: State-of-the-art assessment  

SciTech Connect

The objectives of this document are to present an overview of the work accomplished to date on desiccant cooling to provide assessment of the state of the art of desiccant cooling technology in the field of desiccant material dehumidifier components, desiccant systems, and models. The report also discusses the factors that affect the widespread acceptance of desiccant cooling technology. This report is organized as follows. First, a basic description and historical overview of desiccant cooling technology is provided. Then, the recent research and development (R D) program history (focusing on DOE's funded efforts) is discussed. The status of the technology elements (materials, components, systems) is discussed in detail and a preliminary study on the energy impact of desiccant technology is presented. R D needs for advancing the technology in the market are identified. The National Renewable Energy Laboratory's unique desiccant test facilities and their typical outputs are described briefly. Finally, the results of a comprehensive literature search on desiccant cooling are presented in a bibliography. The bibliography contains approximately 900 citations on desiccant cooling.

Pesaran, A.A.; Penney, T.R.; Czanderna, A.W.

1992-10-01T23:59:59.000Z

208

Desiccant cooling: State-of-the-art assessment  

SciTech Connect

The objectives of this document are to present an overview of the work accomplished to date on desiccant cooling to provide assessment of the state of the art of desiccant cooling technology in the field of desiccant material dehumidifier components, desiccant systems, and models. The report also discusses the factors that affect the widespread acceptance of desiccant cooling technology. This report is organized as follows. First, a basic description and historical overview of desiccant cooling technology is provided. Then, the recent research and development (R&D) program history (focusing on DOE`s funded efforts) is discussed. The status of the technology elements (materials, components, systems) is discussed in detail and a preliminary study on the energy impact of desiccant technology is presented. R&D needs for advancing the technology in the market are identified. The National Renewable Energy Laboratory`s unique desiccant test facilities and their typical outputs are described briefly. Finally, the results of a comprehensive literature search on desiccant cooling are presented in a bibliography. The bibliography contains approximately 900 citations on desiccant cooling.

Pesaran, A.A.; Penney, T.R.; Czanderna, A.W.

1992-10-01T23:59:59.000Z

209

Experimental Results on Advanced Rotary Desiccant Dehumidifiers  

E-Print Network (OSTI)

The Solar Energy Research Institute (SERI) has developed the Cyclic Test Facility (CTF) to develop and validate analytical methods for evaluating and predicting the performance of advanced rotary dehumidifiers. This paper describes the CTF, the dehumidifiers tested at the CTF, and the analytical methods used. The results reported provide an engineering data base and a design tool for evaluating rotary dehumidifiers for desiccant cooling applications.

Barathan, D.; Parsons, J. M.; MaClaine-Cross, I.

1986-01-01T23:59:59.000Z

210

Experimental results on advanced rotary desiccant dehumidifiers  

DOE Green Energy (OSTI)

The Solar Energy Research Institute (SERI) has developed the Cyclic Test Facility (CTF) to develop and validate analytical methods for evaluating and predicting the performance of advanced rotary dehumidifiers. This paper describes the CTF, the dehumidifiers tested at the CTF, and the analytical methods used. The results reported provide an engineering data base and a design tool for evaluating rotary dehumidifiers for desiccant cooling applications.

Bharathan, D.; Parsons, J.; Maclaine-cross, I.

1986-08-01T23:59:59.000Z

211

A review of desiccant dehumidification technology  

SciTech Connect

This paper overviews applications of desiccant technology for dehumidifying commercial and institutional buildings. Because of various market, policy, and regulatory factors, this technology is especially attractive for dehumidification applications in the 1990s. After briefly reviewing the principle of operation, the authors present three case studies-for supermarkets, a hotel, and an office building. The authors also discuss recent advances and ongoing research and development activities.

Pesaran, A.A.

1994-10-01T23:59:59.000Z

212

HVAC Efficiency Controls Could Mean Significant Savings | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC Efficiency Controls Could Mean Significant Savings HVAC Efficiency Controls Could Mean Significant Savings HVAC Efficiency Controls Could Mean Significant Savings April 27, 2012 - 11:58am Addthis HVAC Efficiency Controls Could Mean Significant Savings April Saylor April Saylor Former Digital Outreach Strategist, Office of Public Affairs What does this mean for me? Commercial building owners could save an average 38% on their heating & cooling bills just by installing a few new controls onto their HVAC systems. According to a new report from Pacific Northwest National Lab, commercial building owners could save an average 38 percent on their heating and cooling bills just by installing a few new controls onto their HVAC systems. These findings mean significant potential savings for building owners who use commercial rooftop systems - but there's just one problem: the

213

Applications of HVAC System Utilizing Building Thermal Mass in Japan  

NLE Websites -- All DOE Office Websites (Extended Search)

Applications of HVAC System Utilizing Building Thermal Mass in Japan Applications of HVAC System Utilizing Building Thermal Mass in Japan Speaker(s): Katsuhiro Miura Date: January 27, 2012 - 10:00am Location: 90-3122 Seminar Host/Point of Contact: Michael Wetter Buildings have a large thermal capacity and it affects much on building thermal load for the HVAC system. The thermal mass can be utilized also to control the thermal load by storing thermal energy before HVAC operation. There are two ways to store thermal energy. One is by operating the HVAC system and the other is by natural ventilation, mainly at night. The latter could be combined with daily HVAC operation as a hybrid ventilation. Thermal mass storage is useful to decrease the hourly peak load and the daily thermal load and can be used for both cooling and heating purpose.

214

Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger  

NLE Websites -- All DOE Office Websites (Extended Search)

Radial Air Bearing Radial Air Bearing Heat Exchanger Research Project to someone by E-mail Share Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Facebook Tweet about Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Twitter Bookmark Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Google Bookmark Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Delicious Rank Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Digg Find More places to share Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on AddThis.com... About Take Action to Save Energy Partner with DOE

215

Desiccant dehumidification and cooling systems assessment and analysis  

SciTech Connect

The objective of this report is to provide a preliminary analysis of the principles, sensitivities, and potential for national energy savings of desiccant cooling and dehumidification systems. The report is divided into four sections. Section I deals with the maximum theoretical performance of ideal desiccant cooling systems. Section II looks at the performance effects of non-ideal behavior of system components. Section III examines the effects of outdoor air properties on desiccant cooling system performance. Section IV analyzes the applicability of desiccant cooling systems to reduce primary energy requirements for providing space conditioning in buildings. A basic desiccation process performs no useful work (cooling). That is, a desiccant material drying air is close to an isenthalpic process. Latent energy is merely converted to sensible energy. Only when heat exchange is applied to the desiccated air is any cooling accomplished. This characteristic is generic to all desiccant cycles and critical to understanding their operation. The analyses of Section I show that desiccant cooling cycles can theoretically achieve extremely high thermal CoP`s (>2). The general conclusion from Section II is that ventilation air processing is the most viable application for the solid desiccant equipment analyzed. The results from the seasonal simulations performed in Section III indicate that, generally, the seasonal performance of the desiccant system does not change significantly from that predicted for outdoor conditions. Results from Section IV show that all of the candidate desiccant systems can save energy relative to standard vapor-compression systems. The largest energy savings are achieved by the enthalpy exchange devise.

Collier, R.K. Jr. [Collier Engineering, Reno, NV (United States)

1997-09-01T23:59:59.000Z

216

A systems approach to retrofitting residential HVAC systems  

E-Print Network (OSTI)

HVAC System. LBNL 53444. Wendt, R.L. , Ternes, M.P. , O’realized. Other guides (e.g. , Wendt et al. (1997)) are more

McWilliams, J.A.; Walker, I.S.

2004-01-01T23:59:59.000Z

217

Pedernales Electric Cooperative - HVAC Rebate Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Pedernales Electric Cooperative - HVAC Rebate Program Pedernales Electric Cooperative - HVAC Rebate Program Pedernales Electric Cooperative - HVAC Rebate Program < Back Eligibility Commercial Residential Commercial Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Program Info State Texas Program Type Utility Rebate Program Utility Rebate Program Rebate Amount Central AC with Gas Furnace: $300 - $400/unit Heat Pump: $400 - $500/unit Dual-Fuel Heat Pump: $400 - $500/unit Geothermal Heat Pump: $1,000/unit Water-Source Heat Pump: $1,000/unit Provider Pedernales Electric Cooperative Pedernales Electric Cooperative offers equipment rebates to members who install energy efficient HVAC equipment. Eligible equipment includes:

218

Columbia Water & Light- HVAC and Lighting Efficiency Rebates  

Energy.gov (U.S. Department of Energy (DOE))

Columbia Water & Light (CWL) offers rebates to its commercial and industrial customers for the purchase of high efficiency HVAC installations and efficient lighting. Incentives for certain...

219

Algoritmi per la previsione del carico in applicazioni HVAC.  

E-Print Network (OSTI)

??Il lavoro si pone come obiettivo l’applicazione di metodi e algoritmi per la previsione del carico in sistemi HVAC (Heating, Ventilating and Air Conditioning). La… (more)

Simmini, Francesco

2010-01-01T23:59:59.000Z

220

Fault Detection and Diagnosis in Building HVAC Systems.  

E-Print Network (OSTI)

??Building HVAC systems account for more than 30% of annual energy consumption in United States. However, it has become apparent that only in a small… (more)

Najafi, Massieh

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "liquid desiccant hvac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

New developments in noise control for HVAC systems.  

Science Conference Proceedings (OSTI)

The HVAC equipment industry is not known for rapid change. Although control systems have improved rapidly over the past few years

Timothy J. Foulkes

1996-01-01T23:59:59.000Z

222

The impact of filter loading on residential hvac performance.  

E-Print Network (OSTI)

??Buildings are the primary user of energy in the USA. Within homes, the heating, ventilation, and air condition (HVAC) system is the largest energy consumer.… (more)

Kruger, Abraham J.

2013-01-01T23:59:59.000Z

223

System Optimization - The Global Approach to HVAC Control  

E-Print Network (OSTI)

System Optimization is a new approach to HVAC control as implemented by Energy Management Control Systems. System Optimization is defined as electronic building control strategies which treat a building's HVAC components as a complete energy-efficient and coordinated system. Trends in the development of HVAC control strategies are briefly discussed. An example which differentiates between conventional and System Optimization approaches is used to illustrate this new approach. The example discusses aspects of cooling season operation for a typical HVAC system. The paper concludes with four basic principles of System Optimization which are essential for effective control of a building environment.

Thielman, D. E.

1984-01-01T23:59:59.000Z

224

Deposition of biological aerosols on HVAC heat exchangers  

E-Print Network (OSTI)

Methods to Maintain Heat Exchanger Coil Cleanliness. ASHRAEEngineering Foundation on Heat Exchanger Fouling, UnitedAerosols on HVAC Heat Exchangers Jeffrey Siegel and Iain

Siegel, Jeffrey; Walker, Iain

2001-01-01T23:59:59.000Z

225

Deposition of biological aerosols on HVAC heat exchangers  

E-Print Network (OSTI)

Methods to Maintain Heat Exchanger Coil Cleanliness. ASHRAEEngineering Foundation on Heat Exchanger Fouling, Unitedof HVAC Fin and Tube Heat Exchangers, To be published in the

Siegel, Jeffrey; Walker, Iain

2001-01-01T23:59:59.000Z

226

NREL Delivers In-Home HVAC Efficiency Testing Solutions (Fact...  

NLE Websites -- All DOE Office Websites (Extended Search)

Delivers In-Home HVAC Efficiency Testing Solutions Researchers at the National Renewable Energy Laboratory (NREL) have recently developed two simple in-home efficiency test methods...

227

Desiccant cooling and dehumidification opportunities for buildings workshop  

DOE Green Energy (OSTI)

Desiccant cooling and dehumidification technology is gaining acceptance as an option for air-conditioning buildings. Over the last few years, significant advances have been made in desiccant cooling and dehumidification in the private and public sectors. market penetration of desiccant systems in the past has been limited to unique applications. This workshop was an open forum for discussing these unique and potential applications. Workshop participants discussed the state of the art of desiccant materials, components, systems, and applications, both theoretically and experimentally. This document is a compilation of the papers presented in the workshop sessions.

Penney, T.R. (comp.)

1989-10-01T23:59:59.000Z

228

Modeling and Simulation of a Solar Assisted Desiccant Cooling...  

NLE Websites -- All DOE Office Websites (Extended Search)

system comprises a desiccant wheel containing Lithium Chloride in tandem with a rotating heat exchanger and two humidifiers on both supply and return air. The required...

229

IFC HVAC interface to EnergyPlus - A case of expanded interoperability for energy simulation  

E-Print Network (OSTI)

D. Sucic and P. Xu. 2002. HVAC Component Data Modeling Using2001. BS-8 project: IFC HVAC extension schemata. http://IFC HVAC INTERFACE TO ENERGYPLUS – A CASE OF EXPANDED

Bazjanac, Vladimir; Maile, Tobias

2004-01-01T23:59:59.000Z

230

Uncertainties in Achieving Energy Savings from HVAC Maintenance Measures in the Field  

E-Print Network (OSTI)

Uncertainties in Achieving Energy Savings from HVAC Maintenance Measures in the Field Kristin Group, Davis, CA, USA 4 Southern California Edison, Irwindale, CA, USA ABSTRACT HVAC maintenance utilities across the nation to include HVAC maintenance measures in energy efficiency programs

California at Davis, University of

231

Analysis of a hybrid UFAD and radiant hydronic slab HVAC system  

E-Print Network (OSTI)

Air- Conditioning Engineers HVAC & R Research, vol. 50, Sep.and radiant hydronic slab HVAC system.   Paul RAFTERY a,* ,of a novel integrated HVAC system. This system combines an

Raftery, Paul; Lee, Kwang Ho; Webster, Thomas; Bauman, Fred

2011-01-01T23:59:59.000Z

232

Report on HVAC option selections for a relocatable classroom energy and indoor environmental quality field study  

E-Print Network (OSTI)

LBNL- 49026 Report on HVAC Option Selections for aTable 3. High performance HVAC system filter selectionDrop ("H 2 O) Appendix A – RC HVAC working drawings. Figure

2001-01-01T23:59:59.000Z

233

SIMULATION AND EXPERIMENTAL VALIDATION OF AIRBORNE AND STRUCTURE-BORNE NOISE TRANSMISSION IN HVAC PLENUMS.  

E-Print Network (OSTI)

??This research demonstrates the usage of numerical acoustics to model sound and vibrational energy propagation in HVAC ducts and plenums. Noise and vibration in HVAC… (more)

Ramalingam, Srinivasan

2012-01-01T23:59:59.000Z

234

Reliability and Functional Availability of HVAC Systems  

E-Print Network (OSTI)

This paper presents a model to calculate the reliability and availability of heating, ventilation and air conditioning systems. The reliability is expressed in the terms of reliability, maintainability and decision capability. These terms are a function of the mean time between failure, mean time to repair and decision time. The availability is expressed as an operational and functional availability of the systems. These terms are a function of both the technical and human characteristics to maintain the systems in correct operational state. The result is based on a large amount data from operational organisations, the compulsory inspection of ventilation systems and momentary and continuous measurements made in HVAC-systems.

Myrefelt, S.

2004-01-01T23:59:59.000Z

235

Lighting/HVAC interactions and their effects on annual and peak HVAC requirements in commercial buildings  

SciTech Connect

Lighting measures is one effective strategy for reducing energy use in commercial buildings. Reductions in lighting energy have secondary effects on cooling/heating energy consumption and peak HVAC requirements; in general, they increase the heating and decrease cooling requirements of a building. Net change in a building`s annual and peak energy requirements, however, is difficult to quantify and depends on building characteristics, operating conditions, climate. This paper characterizes impacts of lighting/HVAC interactions on annual and peak heating/cooling requirements of prototypical US commercial buildings through computer simulations using DOE-2.1E building energy analysis program. Ten building types of two vintages and nine climates are chosen to represent the US commercial building stock. For each combination, a prototypical building is simulated with two lighting power densities, and resultant changes in heating and cooling loads are recorded. Simple concepts of Lighting Coincidence Factors are used to describe the observed interactions between lighting and HVAC requirements. (Coincidence Factor (CF) is ratio of changes in HVAC loads to those in lighting loads, where load is either annual or peak load). The paper presents tables of lighting CF for major building types and climates. These parameters can be used for regional or national cost/benefit analyses of lighting- related policies and utility DSM programs. Using Annual CFs and typical efficiencies for heating and cooling systems, net changes in space conditioning energy use from a lighting measure can be calculated. Similarly, Demand CFs can be used to estimate the changes in HVAC sizing, which can then be converted to changes in capital outlay using standard-design curves; or they can be used to estimate coincident peak reductions for the analysis of the utility`s avoided costs. Results from use of these tables are meaningful only when they involve a significantly large number of buildings.

Sezgen, A.O.; Huang, Y.J.

1994-08-01T23:59:59.000Z

236

A desiccant dehumidifier for electric vehicle heating  

DOE Green Energy (OSTI)

Vehicle heating requires a substantial amount of energy. Engines in conventional cars produce enough waste heat to provide comfort heating and defogging/defrosting, even under very extreme conditions. Electric vehicles (EVs), however, generate little waste heat. Using battery energy for heating may consume a substantial fraction of the energy storage capacity, reducing the vehicle range, which is one of the most important parameters in determining EV acceptability. Water vapor generated by the vehicle passengers is in large part responsible for the high heating loads existing in vehicles. In cold climates, the generation of water vapor inside the car may result in water condensation on the windows, diminishing visibility. Two strategies are commonly used to avoid condensation on windows: windows are kept warm, and a large amount of ambient air is introduced in the vehicle. Either strategy results in a substantial heating load. These strategies are often used in combination, and a trade-off exists between them. If window temperature is decreased, ventilation rate has to be increased. Reducing the ventilation rate requires an increase of the temperature of the windows to prevent condensation. An alternative solution is a desiccant dehumidifier, which adsorbs water vapor generated by the passengers. Window temperatures and ventilation rates can then be reduced, resulting in a substantially lower heating load. This paper explores the dehumidifier heating concept. The first part shows the energy savings that could be obtained by using this technology. The second part specifies the required characteristics and dimensions of the system. The results indicate that the desiccant system can reduce the steady-state heating load by 60% or more under typical conditions. The reduction in heating load is such that waste heat may be enough to provide the required heating under most ambient conditions. Desiccant system dimensions and weight appear reasonable for packaging in an EV.

Aceves, S.M.; Smith, J.R.

1996-09-01T23:59:59.000Z

237

The Application of Ultraviolet Germicidal Technology in HVAC Systems  

E-Print Network (OSTI)

One of the most significant issues for today's HVAC (Heating, Ventilation, and Air Conditioning) engineer is Indoor Air Quality (IAQ). Many building owners, operators, and occupants complain of foul odors emanating from HVAC systems. The objectionable odor is the byproduct of the microbial growth (mold and fungus) that accumulates and develops on wet surfaces of HVAC units, causing foul odors to emanate from affected systems and degrading the IAQ and unit performance. This objectionable odor has been appropriately named the "Dirty Sock" syndrome. Less obvious to the building occupants, but of equal importance, are the physical effects the microbial organisms have on HVAC equipment. They restrict the airflow and limit the heat transfer capability, which increases the operating costs of the equipment. Fortunately, IAQ degradation, foul odor, and increased expenses can be eliminated with the installation of the ultraviolet 'C' band (W-C) lamps. The ultraviolet germicidal lamps are designed to kill odor causing mold and fungus that grow in wet evaporator sections of HVAC units. These lamps are installed inside HVAC systems and irradiate areas inhabited by the offending organisms, making it impossible for them to survive. The organisms disappear, the odors disappear, and most importantly, the IAQ complaints disappear. This guide will discuss the microbial growth and IAQ contaminant problems in the HVAC industry, the W-C lamp and other possible solutions, and the benefits of using the HVAC Duty W-C lamp.

Taylor, M. J.

2000-01-01T23:59:59.000Z

238

Industrial HVAC Air-to-Air Energy Recovery Retrofit Economics  

E-Print Network (OSTI)

Retrofitting air-to-air energy recovery equipment is relatively simply to design and easy to install. Additionally, HVAC energy recovery is almost risk free when compared to process retrofit. Life cycle cost analysis is the best way to illustrate the economic attractiveness of retrofitting HVAC industrial energy recovery equipment.

Graham, E. L.

1980-01-01T23:59:59.000Z

239

Theoretical Minimum Energy Use of a Building HVAC System  

E-Print Network (OSTI)

This paper investigates the theoretical minimum energy use required by the HVAC system in a particular code compliant office building. This limit might be viewed as the "Carnot Efficiency" for HVAC system. It assumes that all ventilation and air conditioning in the building are provided using the minimum energy value that does not violate physical law.

Tanskyi, O.

2011-01-01T23:59:59.000Z

240

HVAC & Building Management Control System Energy Efficiency Replacements  

SciTech Connect

The project objective was the replacement of an aging, un-repairable HVAC system which has grown inefficient and a huge energy consumer with low energy and efficient HVAC units, and installation of energy efficient building control technologies at City's YMCA Community Center.

Hernandez, Adriana

2012-09-21T23:59:59.000Z

Note: This page contains sample records for the topic "liquid desiccant hvac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Advanced Desiccant Cooling and Dehumidification Program  

DOE Green Energy (OSTI)

The use of dessicant materials for cooling and dehumidification is an effective, economical, environmentally safe method for meeting indoor air quality standards established by the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). To maximize the technology's potential for reducing energy consumption and improving indoor air quality, DOE established the Advanced Desiccant Cooling and Dehumidification Program. The National Renewable Energy Laboratory partners with industry to support and educate industry users, as well as to support technology transfer and benchmark current performance.

Slayzak, S.

1999-08-24T23:59:59.000Z

242

Columbia Water and Light - HVAC and Lighting Efficiency Rebates |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Columbia Water and Light - HVAC and Lighting Efficiency Rebates Columbia Water and Light - HVAC and Lighting Efficiency Rebates Columbia Water and Light - HVAC and Lighting Efficiency Rebates < Back Eligibility Commercial Industrial Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Lighting: 50% of invoiced cost up to $22,500 Program Info State Missouri Program Type Utility Rebate Program Rebate Amount HVAC Replacements: $570 - $3,770 Lighting: $300/kW reduction or half of project cost Provider Columbia Water and Light Columbia Water and Light (CWL) offers rebates to its commercial and industrial customers for the purchase of high efficiency HVAC installations and efficient lighting. Incentives for certain measures are based upon the

243

Building Energy Software Tools Directory: HVAC 1 Toolkit  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC 1 Toolkit HVAC 1 Toolkit HVAC 1 Toolkit logo. The Toolkit for Primary HVAC System Energy Calculations is a collection of thirty-eight separate subroutines and corresponding documentation that describes algorithms for predicting the performance of HVAC components. The Toolkit documentation includes thorough descriptions of the component models and solution algorithms, detailed information on the structure of the individual FORTRAN 77 routines, as well as illustrative examples of system simulations with the Toolkit routines. The Toolkit serves two purposes: modules for large-scale simulation and stand-alone component performance prediction. The Toolkit components can also be used to calculate the energy performance of a component with a dedicated driver program to provide the necessary information flow to the Toolkit routines.

244

A Fault Detection and Diagnosis Method for HVAC Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

A Fault Detection and Diagnosis Method for HVAC Systems A Fault Detection and Diagnosis Method for HVAC Systems Speaker(s): Peng Xu Date: December 2, 2002 - 12:00pm Location: Bldg. 90 There is a growing consensus that most buildings do not perform as well as intended and that faults in HVAC systems are widespread in commercial buildings. An automated fault detection and diagnosis tool for HVAC systems is being developed, based on an integrated, life-cycle, approach to commissioning and performance monitoring. The tool uses component-level HVAC equipment models implemented in the SPARK equation-based simulation environment. The models are configured using design information and component manufacturers' data and then fine-tuned to match the actual performance of the equipment by using data measured during functional tests

245

Modeling and Simulation of a Solar Assisted Desiccant Cooling System  

NLE Websites -- All DOE Office Websites (Extended Search)

Modeling and Simulation of a Solar Assisted Desiccant Cooling System Modeling and Simulation of a Solar Assisted Desiccant Cooling System Speaker(s): Chadi Maalouf Date: December 2, 2004 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Peng Xu Increased living standards and high occupants comfort demands lead to a growth in air conditioning market. This results in high energy consumption and high CO2 emissions. For these reasons, the solar desiccant cooling system is proposed as an alternative to traditional air conditioning systems. This system comprises a desiccant wheel containing Lithium Chloride in tandem with a rotating heat exchanger and two humidifiers on both supply and return air. The required regeneration temperature for the desiccant wheel varies between 40oC and 70oC which makes possible the use

246

Interdisciplinary Innovation and Vision in the HVAC  

E-Print Network (OSTI)

High energy costs in buildings are forcing the building owners, developers, fund and facility managers to find alternate energy efficiency methods while improving the indoor air quality and thus the comfort level of the room occupants. High potentials for optimizing costs can be found in the HVAC systems when calculated over the total Life-Cycle-Cost (LCC) of a building incorporating planning through to facility management. This requires an accurate plan specifying an efficient technical operating method with optimized energy cost efficiency and comfort for the room occupants. In turn, the plan should be considered in any bidding process. Multisensory equipment is an integral part of the LCC concept and should not be underestimated in its impact on energy efficiency. The possibility of customizing the requirements of the room occupants should be included in each specification of a building/room automation system. The following case study will explain how modern sensory systems can be used for investment and energy savings in various HVAC system.

Hecker, T.

2008-01-01T23:59:59.000Z

247

Simulation of residential HVAC system performance  

SciTech Connect

In many parts of North America residential HVAC systems are installed outside conditioned space. This leads to significant energy losses and poor occupant comfort due to conduction and air leakage losses from the air distribution ducts. In addition, cooling equipment performance is sensitive to air flow and refrigerant charge that have been found to be far from manufacturers specifications in most systems. The simulation techniques discussed in this paper were developed in an effort to provide guidance on the savings potentials and comfort gains that can be achieved by improving ducts (sealing air leaks) and equipment (correct air-flow and refrigerant charge). The simulations include the complex air flow and thermal interactions between duct systems, their surroundings and the conditioned space. They also include cooling equipment response to air flow and refrigerant charge effects. Another key aspect of the simulations is that they are dynamic--which accounts for cyclic losses from the HVAC system and the effect of cycle length on energy and comfort performance.

Walker, I.S.; Siegel, J.A.; Degenetais, G.

2001-05-01T23:59:59.000Z

248

Modeling and Measurement Constraints in Fault Diagnostics for HVAC Systems Massieh Najafi1  

E-Print Network (OSTI)

Modeling and Measurement Constraints in Fault Diagnostics for HVAC Systems Massieh Najafi1 , David for determining HVAC diagnostics, methods to detect faults in HVAC systems are still generally undeveloped. Most in a substantial increase in energy use. For example, failure of an HVAC fan may prevent cool air from one

249

The influence of HVAC systems on secondary organic aerosol formation Michael S. Waring1  

E-Print Network (OSTI)

The influence of HVAC systems on secondary organic aerosol formation Michael S. Waring1 , Jeffrey A, ventilation, and air- conditioning (HVAC) system. This study models the influence of HVAC systems on SOA. The most influential HVAC parameters are the flow rates, particle filtration, and indoor temperature

Siegel, Jeffrey

250

Best Practices for Energy Efficient Cleanrooms Efficient HVAC Systems: Variable-Speed-Drive Chillers  

E-Print Network (OSTI)

LBNL-58636 Best Practices for Energy Efficient Cleanrooms Efficient HVAC Systems: Variable Efficient Cleanrooms Efficient HVAC Water Systems: Variable-Speed-Drive Chillers Tengfang Xu Contents HVAC.................................................................................................................................... 6 #12;HVAC Water Systems Variable-Speed-Drive Chillers Summary Cleanroom energy benchmarking data

251

A multi-sensor based occupancy estimation model for supporting demand driven HVAC operations  

Science Conference Proceedings (OSTI)

Heating, ventilation, and air conditioning (HVAC) is a major energy consumer in buildings, and implementing demand driven HVAC operations is a way to reduce HVAC related energy consumption. This relies on the availability of occupancy information, which ... Keywords: HVAC, building energy consumption, demand driven, non-intrusive sensor, occupancy estimation

Zheng Yang; Nan Li; Burcin Becerik-Gerber; Michael Orosz

2012-03-01T23:59:59.000Z

252

Classroom HVAC: Improving ventilation and saving energy -- field study plan  

SciTech Connect

The primary goals of this research effort are to develop, evaluate, and demonstrate a very practical HVAC system for classrooms that consistently provides classrooms (CRs) with the quantity of ventilation in current minimum standards, while saving energy, and reducing HVAC-related noise levels. This research is motivated by the public benefits of energy efficiency, evidence that many CRs are under-ventilated, and public concerns about indoor environmental quality in CRs. This document provides a summary of the detailed plans developed for the field study that will take place in 2005 to evaluate the energy and IAQ performance of a new classroom HVAC technology. The field study will include measurements of HVAC energy use, ventilation rates, and IEQ conditions in 10 classrooms with the new HVAC technology and in six control classrooms with a standard HVAC system. Energy use and many IEQ parameters will be monitored continuously, while other IEQ measurements will be will be performed seasonally. Continuously monitored data will be remotely accessed via a LonWorks network. Instrument calibration plans that vary with the type of instrumentation used are established. Statistical tests will be employed to compare energy use and IEQ conditions with the new and standard HVAC systems. Strengths of this study plan include the collection of real time data for a full school year, the use of high quality instrumentation, the incorporation of many quality control measures, and the extensive collaborations with industry that limit costs to the sponsors.

Apte, Michael G.; Faulkner, David; Hodgson, Alfred T.; Sullivan, Douglas P.

2004-10-14T23:59:59.000Z

253

Polymers as advanced materials for desiccant applications, 1988  

DOE Green Energy (OSTI)

This report documents work to identify a next-generation, low-cost material with which solar energy or heat from another low-cost energy source can be used for regenerating the water vapor sorption activity of the desiccant. The objective of the work is to determine how the desired sorption performance of advanced desiccant materials can be predicted by understanding the role of the material modifications and material surfaces. The work concentrates on solid materials to be used for desiccant cooling systems and which process water vapor in an atmosphere to produce cooling. The work involved preparing modifications of polystyrene sulfonic acid sodium salt, synthesizing a hydrogel, and evaluating the sorption performances of these and similar commercially available polymeric materials; all materials were studied for their potential application in solid commercial desiccant cooling systems. Background information is also provided on desiccant cooling systems and the role of a desiccant material within such a system, and it includes the use of polymers as desiccant materials. 31 refs., 16 figs., 5 tabs.

Czanderna, A.W.; Neidlinger, H.H.

1990-09-01T23:59:59.000Z

254

Self-Correcting HVAC Controls Project Final Report  

SciTech Connect

This document represents the final project report for the Self-Correcting Heating, Ventilating and Air-Conditioning (HVAC) Controls Project jointly funded by Bonneville Power Administration (BPA) and the U.S. Department of Energy (DOE) Building Technologies Program (BTP). The project, initiated in October 2008, focused on exploratory initial development of self-correcting controls for selected HVAC components in air handlers. This report, along with the companion report documenting the algorithms developed, Self-Correcting HVAC Controls: Algorithms for Sensors and Dampers in Air-Handling Units (Fernandez et al. 2009), document the work performed and results of this project.

Fernandez, Nicholas; Brambley, Michael R.; Katipamula, Srinivas; Cho, Heejin; Goddard, James K.; Dinh, Liem H.

2010-01-04T23:59:59.000Z

255

Unusual HVAC challenges require innovative solutions  

SciTech Connect

There were many reasons behind Motorola`s decision to build the first 225,000 sq ft of a planned one million sq ft manufacturing facility in Chihuahua, Mexico. Among these were the availability of skilled labor in the area, lower construction costs, some export tax advantages, and the close proximity to the US border. The new facility is made up of a variety of functional areas that together create an impressively efficient plant. Phase 1 construction included a large manufacturing floor, shipping and receiving areas, a bulk storage facility, and a large office area with a view of the factory floor. The structure also houses a retail store where Motorola consumer products are sold, a conference and banquet center, a commercial kitchen, and dining facilities for 750. The design cooling load is 750 tons; the heating load is 4.5 million Btuh. The paper discusses the challenging location, the HVAC system, and the future expansion planned.

Jardine, G.M.; Gwin, O.D. [Heery International, Inc., Atlanta, GA (United States)

1998-02-01T23:59:59.000Z

256

SURFACE INDUSTRIAL HVAC SYSTEM DESCRIPTION DOCUMENT  

SciTech Connect

The purpose of this system description document (SDD) is to establish requirements that drive the design of the surface industrial heating, ventilation, and air-conditioning (HVAC) system and its bases to allow the design effort to proceed to license application. This SDD will be revised at strategic points as the design matures. This SDD identifies the requirements and describes the system design, as it currently exists, with emphasis on attributes of the design provided to meet the requirements. This SDD is an engineering tool for design control; accordingly, the primary audience and users are design engineers. This SDD is part of an iterative design process. It leads the design process with regard to the flowdown of upper tier requirements onto the system. Knowledge of these requirements is essential to performing the design process. The SDD follows the design with regard to the description of the system. The description that provided in this SDD reflects the current results of the design process.

M.M. Ansari

2005-04-05T23:59:59.000Z

257

HVAC system analysis: energy audit review  

SciTech Connect

Although most energy audits do not investigate HVAC systems in as much detail as would most design consultants, audit data can be most informative. For certain types of buildings, air-conditioning energy usage can be estimated by its absence from energy bills during winter months, and heating energy usage can be estimated by its absence from energy bills during the summer months. Cooling and heating energy usage can be even more accurately broken down when a fossil fuel is used for heating while electrical energy is used for cooling. It is easy to establish fairly accurate energy consumption estimates for lighting, fan motors, and pumps; this can be done by verifying their loads and multiplying them by known operating hours. The numerous notes contained in some energy audits may also provide ideas for retrofitting energy-consuming areas.

Harmon, K.S.

1983-01-01T23:59:59.000Z

258

Distributed Control of HVAC&R Networks  

E-Print Network (OSTI)

Heating, ventilation, air conditioning, and refrigeration (HVAC&R) systems are a major component of worldwide energy consumption, and frequently consist of complex networks of interconnected components. The ubiquitous nature of these systems suggests that improvements in their energy efficiency characteristics can have significant impact on global energy consumption. The complexity of the systems, however, means that decentralized control schemes will not always suffice to balance competing goals of energy efficiency and occupant comfort and safety. This dissertation proposes control solutions for three facets of this problem. The first is a cascaded control architecture for actuators, such as electronic expansion valves, that provides excellent disturbance rejection and setpoint tracking characteristics, as well as partial nonlinearity compensation without a compensation model. The second solution is a hierarchical control architecture for multiple-evaporator vapor compression systems that uses model predictive control (MPC) at both the supervisory and component levels. The controllers leverage the characteristics of MPC to balance energy efficiency with occupant comfort. Since the local controllers are decentralized, the architecture retains a degree of modularity—changing one component does not require changing all controllers. The final contribution is a new distributed optimization algorithm that is rooted in distributed MPC and is especially motivated by HVAC&R systems. This algorithm allows local level optimizers to iterate to a centralized solution. The optimizers have no knowledge of any plant other than the plant they are associated with, and only need to communicate with their immediate neighbors. The efficacy of the algorithm is displayed with two sets of examples. One example is simulation based, wherein a building is modeled in the EnergyPlus software suite. The other is an experimental example. In this example, the algorithm is applied to a multiple evaporator vapor compression system. In both cases the design method is discussed, and the ability of the algorithm to reduce energy consumption when properly applied is demonstrated.

Elliott, Matthew Stuart

2013-08-01T23:59:59.000Z

259

Analysis of advanced solar hybrid desiccant cooling systems for buildings  

DOE Green Energy (OSTI)

This report describes an assessment of the energy savings possible from developing hybrid desiccant/vapor-compression air conditioning systems. Recent advances in dehumidifier design for solar desiccant cooling systems have resulted in a dehumidifier with a low pressure drop and high efficiency in heat and mass transfer. A recent study on hybrid desiccant/vapor compression systems showed a 30%-80% savings in resource energy when compared with the best conventional systems with vapor compression. A system consisting of a dehumidifier with vapor compression subsystems in series was found to be the simplest and best overall performer.

Schlepp, D.; Schultz, K.

1984-10-01T23:59:59.000Z

260

Regeneration characteristics of adsorbent in the integrated desiccant/collector  

SciTech Connect

This study presents a solar desiccant system using an adsorbent in an integrated desiccant/solar collector that uses direct solar energy as a heat source for efficient regeneration of the adsorbent. The objective of this study is to investigate an integrated desiccant/collector in which the adsorbent absorbs solar radiation fully and is heated for regeneration. Another objective is to obtain the regeneration characteristics in the equipment proposed by both experiments and simulations. Throughout this study, silica gel is used as the adsorbent.

Saito, Y. (Osaka Inst. of Technology (Japan). Dept. of Mechanical Engineering)

1993-08-01T23:59:59.000Z

Note: This page contains sample records for the topic "liquid desiccant hvac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Field Demonstration of Active Desiccant Modules Designed to Integrate with Standard Unitary Rooftop Package Equipment - Final Report: Phase 3  

SciTech Connect

This report summarizes the investigation of two active desiccant module (ADM) pilot site installations initiated in 2001. Both pilot installations were retrofits at existing facilities served by conventional heating, ventilating, and air-conditioning (HVAC) systems that had encountered frequent humidity control, indoor air quality (IAQ), and other operational problems. Each installation involved combining a SEMCO, Inc., ADM (as described in Fischer and Sand 2002) with a standard packaged rooftop unit built by the Trane Company. A direct digital control (DDC) system integral to the ADM performed the dual function of controlling the ADM/rooftop combination and facilitating data collection, trending, and remote performance monitoring. The first installation involved providing preconditioned outdoor air to replace air exhausted from the large kitchen hood and bathrooms of a Hooters restaurant located in Rome, Georgia. This facility had previously added an additional rooftop unit in an attempt to achieve occupant comfort without success. The second involved conditioning the outdoor air delivered to each room of a wing of the Mountain Creek Inn at the Callaway Gardens resort. This hotel, designed in the ''motor lodge'' format with each room opening to the outdoors, is located in southwest Georgia. Controlling the space humidity always presented a serious challenge. Uncomfortable conditions and musty odors had caused many guests to request to move to other areas within the resort. This is the first field demonstration performed by Oak Ridge National Laboratory where significant energy savings, operating cost savings, and dramatically improved indoor environmental conditions can all be claimed as the results of a retrofit desiccant equipment field installation. The ADM/rooftop combination installed at the restaurant resulted in a reduction of about 34% in the electricity used by the building's air-conditioning system. This represents a reduction of approximately 15% in overall electrical energy consumption and a 12.5-kW reduction in peak demand. The cost of gas used for regeneration of the desiccant wheel over this period of time is estimated to be only $740, using a gas cost of $0.50 per therm--the summer rate in 2001. The estimated net savings is $5400 annually, resulting in a 1-2 year payback. It is likely that similar energy/cost savings were realized at the Callaway Gardens hotel. In this installation, however, a central plant supplied the chilled water serving fan coil units in the hotel wing retrofitted with the ADM, so it was not metered separately. Consequently, the owner could not provide actual energy consumption data specific to the facility. The energy and operating cost savings at both sites are directly attributable to higher cooling-season thermostat settings and decreased conventional system run times. These field installations were selected as an immediate and appropriate response to correct indoor humidity and fresh air ventilation problems being experienced by building occupants and owners, so no rigorous baseline-building vs. test-building energy use/operating cost savings results can be presented. The report presents several simulated comparisons between the ADM/roof HVAC approach and other equipment combinations, where both desiccant and conventional systems are modeled to provide comparable fresh air ventilation rates and indoor humidity levels. The results obtained from these simulations demonstrate convincingly the energy and operating cost savings obtainable with this hybrid desiccant/vapor-compression technology, verifying those actually seen at the pilot installations. The ADM approach is less expensive than conventional alternatives providing similar performance and indoor air quality and provides a very favorable payback (1 year or so) compared with oversized rooftop units that cannot be operated effectively with the necessary high outdoor air percentages.

Fischer, J

2004-03-15T23:59:59.000Z

262

Co-simulation for performance prediction of integrated building and HVAC systems - An analysis of solution characteristics using a two-body system  

E-Print Network (OSTI)

of innovative integrated HVAC systems in buildings, infor building envelope and HVAC systems simu- lation - WillIntegrated simulation for HVAC performance prediction: State

Trcka, Marija

2010-01-01T23:59:59.000Z

263

Fault Detection and Diagnosis in Building HVAC Systems  

E-Print Network (OSTI)

techniques for model-based FDD methods applied to vapordetection and diagnosis (FDD) has been an active area for6-17]. In building HVAC systems, FDD has received increasing

Najafi, Massieh

2010-01-01T23:59:59.000Z

264

Connexus Energy - Residential Efficient HVAC Rebate Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Connexus Energy - Residential Efficient HVAC Rebate Program Connexus Energy - Residential Efficient HVAC Rebate Program Connexus Energy - Residential Efficient HVAC Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Program Info Expiration Date 12/31/2013 State Minnesota Program Type Utility Rebate Program Rebate Amount Air Source Heat Pumps: $480 - $630 Ductless Heat Pump: $150 Geothermal Heat Pump: $200/ton Provider Connexus Energy Connexus Energy offers rebates for residential customers to improve the energy efficiency of homes. Rebates are available for air source heat pumps, ductless heat pumps and ground-source heat pumps. Equipment must meet all efficiency standards listed on the web site, and must be installed by a certified HVAC contractor. Contact Connexus Energy for other program

265

Strategy Guideline: Transitioning HVAC Companies to Whole House Performance Contractors  

Science Conference Proceedings (OSTI)

This report describes the findings from research IBACOS conducted related to heating, ventilation, and air conditioning (HVAC) companies who have made the decision to transition to whole house performance contracting (WHPC).

Burdick, A.

2012-05-01T23:59:59.000Z

266

Direct Digital Control for Building HVAC Systems, 2nd edition  

Science Conference Proceedings (OSTI)

From the Publisher:Direct Digital Control for Building HVAC Systems, Second Edition, is thoroughly updated and expanded to include complete coverage of the architecture of modern digital control systems, distributed intelligence networked systems, communication ...

Michael J. L. Coffin

1998-06-01T23:59:59.000Z

267

Review of Residential Low-Load HVAC Systems  

SciTech Connect

In support of the U.S. Department of Energy’s (DOE’s) Building America Program, Pacific Northwest National Laboratory (PNNL) conducted an investigation to inventory commercially available HVAC technologies that are being installed in low-load homes. The first step in this investigation was to conduct a review of published literature to identify low-load HVAC technologies available in the United States and abroad, and document the findings of existing case studies that have evaluated the performance of the identified technologies. This report presents the findings of the literature review, identifies gaps in the literature or technical understanding that must be addressed before low-load HVAC technologies can be fully evaluated, and introduces PNNL’s planned research and analysis for this project to address identified gaps and potential future work on residential low-load HVAC systems.

Brown, Scott A.; Thornton, Brian; Widder, Sarah H.

2013-09-01T23:59:59.000Z

268

DOE Convening Report on Certification of Commercial HVAC and...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Convening Report on Certification of Commercial HVAC and CRE Products, October 2, 2012 1 U.S. DEPARTMENT OF ENERGY CONVENING REPORT ON THE FEASIBILITY OF A NEGOTIATED RULEMAKING TO...

269

Software-Based Building Airflow Analysis Tool for Enabling HVAC...  

NLE Websites -- All DOE Office Websites (Extended Search)

Software-Based Building Airflow Analysis Tool for Enabling HVAC Energy Use Savings in Commercial Buildings Speaker(s): Don Wroblewski Date: March 8, 2013 - 12:00pm Location:...

270

Temporal model-based diagnostics generation for HVAC control systems  

Science Conference Proceedings (OSTI)

Optimizing energy usage in buildings requires global models that integrate multiple factors contributing to energy, such as lighting, "Heating, Ventilating, and Air Conditioning" (HVAC), security, etc. Model transformation methods can then use these ...

Marion Behrens; Gregory Provan

2010-06-01T23:59:59.000Z

271

The Optimization of Control Parameters for VAV HVAC System Commissioning  

E-Print Network (OSTI)

One of the technical subjects in commissioning for HVAC system is to enhance control performance and time efficiency, while the tuning of the optimal parameters to control HVAC system takes much time and labor in particular. Therefore, we propose a kind of commissioning technique as follows. We identified the dynamic characteristics of components of an actual VAV HVAC system such as rooms, VAV dampers, two way valves and chilled water coils, and verified the behaviors of the models and choose the optimal control parameters on a personal computer. Then adopting them for the actual system, we verified the control performance. Through the procedure, we showed the possibility of off-site and off-line control parameter tuning to reduce the cost and time at on-site and in on-line using the measured data in a real HVAC system.

Song, S.; Maehara, K.; Sagara, N.

2006-01-01T23:59:59.000Z

272

Columbia Water and Light- Residential HVAC Rebate Program  

Energy.gov (U.S. Department of Energy (DOE))

Columbia Water and Light (CWL) provides an HVAC incentive for residential customers that are replacing an older heating and cooling system. Customers should submit the mechanical permit from a...

273

Sound quality descriptors for HVAC equipment from ARI Standards  

Science Conference Proceedings (OSTI)

The Air Conditioning and Refrigeration Institute (ARI) has several standards that provide methods to evaluate the sound quality of heating ventilating and air?conditioning (HVAC) equipment. These include Standard 270 Sound rating of outdoor unitary equipment

2003-01-01T23:59:59.000Z

274

Commissioning and Performance Diagnostics for HVAC Control Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

Commissioning and Performance Diagnostics for HVAC Control Systems Speaker(s): Ashish Singhal Date: December 20, 2006 - 12:00pm Location: 90-3122 Seminar HostPoint of Contact:...

275

Adaptive Control and Fault Detection of HVAC Equipment in Commercial...  

NLE Websites -- All DOE Office Websites (Extended Search)

Adaptive Control and Fault Detection of HVAC Equipment in Commercial Buildings Speaker(s): John Seem Date: February 27, 2002 - 12:00pm Location: Bldg. 90 Seminar HostPoint of...

276

Optimized HVAC Management Service to Enhance Demand Response  

NLE Websites -- All DOE Office Websites (Extended Search)

Optimized HVAC Management Service to Enhance Demand Response Speaker(s): John Steinberg Date: August 18, 2011 - 12:00pm Location: 90-4133 Seminar HostPoint of Contact: Janie Page...

277

Applications of HVAC System Utilizing Building Thermal Mass in...  

NLE Websites -- All DOE Office Websites (Extended Search)

Applications of HVAC System Utilizing Building Thermal Mass in Japan Speaker(s): Katsuhiro Miura Date: January 27, 2012 - 10:00am Location: 90-3122 Seminar HostPoint of Contact:...

278

Neural network based optimal control of HVAC&R systems.  

E-Print Network (OSTI)

??Heating, Ventilation, Air-Conditioning and Refrigeration (HVAC&R) systems have wide applications in providing a desired indoor environment for different types of buildings. It is well acknowledged… (more)

Ning, Min

2008-01-01T23:59:59.000Z

279

HVAC system modeling and optimization: a data-mining approach.  

E-Print Network (OSTI)

?? Heating, ventilating and air-conditioning (HVAC) system is complex non-linear system with multi-variables simultaneously contributing to the system process. It poses challenges for both system… (more)

Tang, Fan

2010-01-01T23:59:59.000Z

280

LBL-34045 UC-1600 Residential HVAC Data, Assumptions and Methodology  

NLE Websites -- All DOE Office Websites (Extended Search)

5 UC-1600 Residential HVAC Data, Assumptions and Methodology for End-Use Forecasting with EPRI-REEPS 2.1 Francis X. Johnson, Richard E. Brown, James W. Hanford, Alan H. Sanstad and...

Note: This page contains sample records for the topic "liquid desiccant hvac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Ameren Illinois (Electric)- Custom, HVAC, and Motor Business Efficiency Incentives  

Energy.gov (U.S. Department of Energy (DOE))

Prescriptive rebates are available for many HVAC and motor efficiency improvements. Pre-approval is required for all rebates. The programs are available only to non-residential customers that...

282

Design for a gas chromatograph for characterizing desiccant material  

DOE Green Energy (OSTI)

To characterize solar desiccant cooling materials, a gas chromatograph has been designed. The chromatograph can record breakthrough curves and equilibrium data under widely varying conditions so that the rates and heats of sorption may be determined. This information may then be used in analyzing models for the construction of desiccant cooling systems which use solar heating for the drying cycle. The effects of desiccant geometry upon bed packing are minimal. However, the effects of desiccant geometry upon the pressure differential across the bed and upon the rate controlling processes may be strong, and these must be investigated thoroughly. Ranges for flow rates and for control of the physical parameters have been selected to encompass those that may be encountered in practical systems. A list of equipment and materials of construction is presented together with a brief description of the operation of the equipment.

Pitts, R.; Czanderna, A.

1980-02-01T23:59:59.000Z

283

Development of a solar desiccant dehumidifier. Third technical progress report  

DOE Green Energy (OSTI)

This program is aimed at the development of a solar desiccant dehumidifier featuring a rotary bed of granular silica gel and a rotary regenerator. Design, fabrication, performance, commercialization studies, and test stand development are described in detail. (WHK)

Gunderson, M.E.

1979-06-12T23:59:59.000Z

284

Measuring advances in HVAC distribution system designs  

Science Conference Proceedings (OSTI)

Substantial commercial building energy savings have been achieved by improving the performance of the HVAC distribution system. The energy savings result from distribution system design improvements, advanced control capabilities, and use of variable-speed motors. Yet, much of the commercial building stock remains equipped with inefficient systems. Contributing to this is the absence of a definition for distribution system efficiency as well as the analysis methods for quantifying performance. This research investigates the application of performance indices to assess design advancements in commercial building thermal distribution systems. The index definitions are based on a first and second law of thermodynamics analysis of the system. The second law or availability analysis enables the determination of the true efficiency of the system. Availability analysis is a convenient way to make system efficiency comparisons since performance is evaluated relative to an ideal process. A TRNSYS simulation model is developed to analyze the performance of two distribution system types, a constant air volume system and a variable air volume system, that serve one floor of a large office building. Performance indices are calculated using the simulation results to compare the performance of the two systems types in several locations. Changes in index values are compared to changes in plant energy, costs, and carbon emissions to explore the ability of the indices to estimate these quantities.

Franconi, Ellen

1998-07-01T23:59:59.000Z

285

Hydraulic conductivity of desiccated geosynthetic clay liners  

SciTech Connect

Large-scale tests were performed to determine the effect of a cycle of wetting and drying on the hydraulic conductivity of several geosynthetic clay liners (GCLs). The GCLs were covered with 0.6 m of pea gravel and permeated with water. After steady seepage had developed, the water was drained away, and the GCL was desiccated by circulating heated air through the overlying gravel. The drying caused severe cracking in the bentonite component of the GCLs. The GCLs were again permeated with water. As the cracked bentonite hydrated and swelled, the hydraulic conductivity slowly decreased from an initially high value. The long-term, steady value of hydraulic conductivity after the wetting and drying cycle was found to be essentially the same as the value for the undesiccated GCL. It is concluded that GCLs possess the ability to self-heal after a cycle of wetting and drying, which is important for applications in which there may be alternate wetting and drying of a hydraulic barrier (e.g. within a landfill final cover).

Boardman, B.T. [CH2M Hill, Oakland, CA (United States); Daniel, D.E. [Univ. of Texas, Austin, TX (United States)

1996-03-01T23:59:59.000Z

286

Influence Of Three Dynamic Predictive Clothing Insulation Models On Building Energy Use, HVAC Sizing And Thermal Comfort  

E-Print Network (OSTI)

ON BUILDING ENERGY USE, HVAC SIZING AND THERMAL COMFORT aThe results showed that when the HVAC is controlled based onequipment sizing. When the HVAC is controlled based on the

Schiavon, Stefano; Lee, Kwang Ho

2013-01-01T23:59:59.000Z

287

Evaluation of commercially available techniques and development of simplified methods for measuring grille airflows in HVAC systems  

E-Print Network (OSTI)

Walker. 2002. “Residential HVAC and Distribution researchMeasuring Grille Airflows in HVAC Systems I.S. Walker, C.P.Measuring Grille Airflows in HVAC Systems I.S. Walker, C.P.

Walker, Iain S.; Wray, Craig P.; Guillot, Cyril; Masson, S.

2003-01-01T23:59:59.000Z

288

Using measured equipment load profiles to "right-size" HVAC systems and reduce energy use in laboratory buildings (Pt. 2)  

E-Print Network (OSTI)

load profiles to “right-size” HVAC systems and reduce energyGeorgia. ASHRAE [1999]. HVAC Applications Handbook 1999.Inefficiency of a Common Lab HVAC System,” presented at the

Mathew, Paul; Greenberg, Steve; Frenze, David; Morehead, Michael; Sartor, Dale; Starr, William

2008-01-01T23:59:59.000Z

289

Residential HVAC Data, Assumptions and Methodology for End-Use Forecasting with EPRI-REEPS 2.1  

E-Print Network (OSTI)

Efficiency Choice 6.3 New Home HVAC System Choice 6.4. NewJuly. EPRI. 1990. REEPS 2.0 HVAC Model Logic, prepared by1990. Review of Equipment HVAC Choice Parameters. Cambridge

Johnson, F.X.

2010-01-01T23:59:59.000Z

290

Building energy modeling programs comparison Research on HVAC systems  

NLE Websites -- All DOE Office Websites (Extended Search)

energy modeling programs comparison Research on HVAC systems energy modeling programs comparison Research on HVAC systems simulation part Title Building energy modeling programs comparison Research on HVAC systems simulation part Publication Type Journal Year of Publication 2013 Authors Zhou, Xin, Da Yan, Tianzhen Hong, and Dandan Zhu Keywords Building energy modeling programs, comparison tests, HVAC system simulation, theory analysis Abstract Building energy simulation programs are effective tools for the evaluation of building energy saving and optimization of design. The fact that large discrepancies exist in simulated results when different BEMPs are used to model the same building has caused wide concern. Urgent research is needed to identify the main elements that contribute towards the simulation results. This technical report summarizes methodologies, processes, and the main assumptions of three building energy modeling programs (BEMPs) for HVAC calculations: EnergyPlus, DeST, and DOE-2.1E, and test cases are designed to analyze the calculation process in detail. This will help users to get a better understanding of BEMPs and the research methodology of building simulation. This will also help build a foundation for building energy code development and energy labeling programs.

291

An evaluation of three commercially available technologies for real-time measurement of rates of outdoor airflow into HVAC systems  

E-Print Network (OSTI)

RATES OF OUTDOOR AIRFLOW INTO HVAC SYSTEMS William J. Fisk,determine flow resistance of hvac ducts and fittings. A S H

Fisk, William J.; Faulkner, David; Sullivan, Douglas P.

2004-01-01T23:59:59.000Z

292

Field Test and Performance Verification: Integrated Active Desiccant Rooftop Hybrid System Installed in a School - Final Report: Phase 4A  

SciTech Connect

This report summarizes the results of a field verification pilot site investigation that involved the installation of a hybrid integrated active desiccant/vapor-compression rooftop heating, ventilation, and air-conditioning (HVAC) unit at an elementary school in the Atlanta Georgia area. For years, the school had experienced serious humidity and indoor air quality (IAQ) problems that had resulted in occupant complaints and microbial (mold) remediation. The outdoor air louvers of the original HVAC units had been closed in an attempt to improve humidity control within the space. The existing vapor compression variable air volume system was replaced by the integrated active desiccant rooftop (IADR) system that was described in detail in an Oak Ridge National Laboratory (ORNL) report published in 2004 (Fischer and Sand 2004). The IADR system and all space conditions have been monitored remotely for more than a year. The hybrid system was able to maintain both the space temperature and humidity as desired while delivering the outdoor air ventilation rate required by American Society of Heating, Refrigerating and Air-Conditioning Engineers Standard 62. The performance level of the IADR unit and the overall system energy efficiency was measured and found to be very high. A comprehensive IAQ investigation was completed by the Georgia Tech Research Institute before and after the system retrofit. Before-and-after data resulting from this investigation confirmed a significant improvement in IAQ, humidity control, and occupant comfort. These observations were reported by building occupants and are echoed in a letter to ORNL from the school district energy manager. The IADR system was easily retrofitted in place of the original rooftop system using a custom curb adapter. All work was completed in-house by the school's maintenance staff over one weekend. A subsequent cost analysis completed for the school district by the design engineer of record concluded that the IADR system being investigated was actually less expensive to install than other less-efficient options, most of which were unable to deliver the required ventilation while maintaining the desired space humidity levels.

Fischer, J

2005-12-21T23:59:59.000Z

293

Issue #7: What are the Best HVAC Solutions for Low-Load, High...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7: What are the Best HVAC Solutions for Low-Load, High Performance Homes? Issue 7: What are the Best HVAC Solutions for Low-Load, High Performance Homes? What components and...

294

WEATHER SEQUENCES FOR PREDICTING HVAC SYSTEM BEHAVIOUR IN RESIDENTIAL UNITS LOCATED IN TROPICAL CLIMATES.  

E-Print Network (OSTI)

WEATHER SEQUENCES FOR PREDICTING HVAC SYSTEM BEHAVIOUR IN RESIDENTIAL UNITS LOCATED IN TROPICAL on the energy needs of HVAC system. We'll apply the method on the tropical Reunion Island. The methodological

Paris-Sud XI, Université de

295

Fight Fall Allergies and Save Energy by Checking Your HVAC System...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Fight Fall Allergies and Save Energy by Checking Your HVAC System Fight Fall Allergies and Save Energy by Checking Your HVAC System October 15, 2012 - 3:19pm Addthis Change your...

296

Critical Question #4: What are the Best Off-the-Shelf HVAC Solutions...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Critical Question 4: What are the Best Off-the-Shelf HVAC Solutions for Low-Load, High-Performance Homes and Apartments? Critical Question 4: What are the Best Off-the-Shelf HVAC...

297

The Effects of Desiccation and Climatic Change on the Hydrology of the Aral Sea  

Science Conference Proceedings (OSTI)

Anthropogenic desiccation of the Aral Sea between 1960 and the mid-1990s resulted in a substantial modification of the land surface that changed air temperature in the surrounding region. During the desiccation interval, the net annual rate of ...

Eric E. Small; Filippo Giorgi; Lisa Cirbus Sloan; Steven Hostetler

2001-02-01T23:59:59.000Z

298

Commissioning and Performance Diagnostics for HVAC Control Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

Commissioning and Performance Diagnostics for HVAC Control Systems Commissioning and Performance Diagnostics for HVAC Control Systems Speaker(s): Ashish Singhal Date: December 20, 2006 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Philip Haves The presentation will focus on practical aspects of commissioning control loops in commercial HVAC systems and evaluating their routine performance. Simple and theoretically sound methods for diagnosing control performance will be presented that detect serious performance issues associated with control loops in modern buildings. The discussion will center on a new control loop commissioning tool that helps field personnel to quickly test, tune and troubleshoot control loops. In addition to the active tests for commissioning control loops, a suite of diagnostic algorithms are used in a

299

Optimized HVAC Management Service to Enhance Demand Response  

NLE Websites -- All DOE Office Websites (Extended Search)

Optimized HVAC Management Service to Enhance Demand Response Optimized HVAC Management Service to Enhance Demand Response Speaker(s): John Steinberg Date: August 18, 2011 - 12:00pm Location: 90-4133 Seminar Host/Point of Contact: Janie Page Many utilities are investing vast sums deploying smart meters to customers, some of whom remain stubbornly opposed to those deployments, in large part because they remain unmoved by the claimed benefits. EcoFactor has developed a thermostat management service that delivers (and quantifies) significant energy savings for consumers and a number of additional benefits to other players in the energy value chain. It does so without relying on consumers to modify behavior, study energy information displays, or even pay attention to their energy use. EcoFactor also significantly boosts DR yield while it increases occupant comfort. It can identify HVAC

300

Energy-Efficient Building HVAC Control Using Hybrid System LBMPC  

E-Print Network (OSTI)

Improving the energy-efficiency of heating, ventilation, and air-conditioning (HVAC) systems has the potential to realize large economic and societal benefits. This paper concerns the system identification of a hybrid system model of a building-wide HVAC system and its subsequent control using a hybrid system formulation of learning-based model predictive control (LBMPC). Here, the learning refers to model updates to the hybrid system model that incorporate the heating effects due to occupancy, solar effects, outside air temperature (OAT), and equipment, in addition to integrator dynamics inherently present in low-level control. Though we make significant modeling simplifications, our corresponding controller that uses this model is able to experimentally achieve a large reduction in energy usage without any degradations in occupant comfort. It is in this way that we justify the modeling simplifications that we have made. We conclude by presenting results from experiments on our building HVAC testbed, which s...

Aswani, Anil; Taneja, Jay; Krioukov, Andrew; Culler, David; Tomlin, Claire

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "liquid desiccant hvac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Active noise control: A tutorial for HVAC designers  

Science Conference Proceedings (OSTI)

This article will identify the capabilities and limitations of ANC in its application to HVAC noise control. ANC can be used in ducted HVAC systems to cancel ductborne, low-frequency fan noise by injecting sound waves of equal amplitude and opposite phase into an air duct, as close as possible to the source of the unwanted noise. Destructive interference of the fan noise and injected noise results in sound cancellation. The noise problems that it solves are typically described as rumble, roar or throb, all of which are difficult to address using traditional noise control methods. This article will also contrast the use of active against passive noise control techniques. The main differences between the two noise control measures are acoustic performance, energy consumption, and design flexibility. The article will first present the fundamentals and basic physics of ANC. The application to real HVAC systems will follow.

Gelin, L.J.

1997-08-01T23:59:59.000Z

302

Ameren Illinois (Electric) - Custom, HVAC, and Motor Business Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ameren Illinois (Electric) - Custom, HVAC, and Motor Business Ameren Illinois (Electric) - Custom, HVAC, and Motor Business Efficiency Incentives Ameren Illinois (Electric) - Custom, HVAC, and Motor Business Efficiency Incentives < Back Eligibility Commercial Industrial Multi-Family Residential Nonprofit Savings Category Other Heating & Cooling Commercial Heating & Cooling Cooling Home Weatherization Construction Commercial Weatherization Design & Remodeling Manufacturing Sealing Your Home Ventilation Heat Pumps Heating Appliances & Electronics Commercial Lighting Lighting Water Heating Maximum Rebate $600,000/year/facility. Incentives $1-$200,000: paid at 100% Incentives $200,000-$600,000: paid at 50% Custom: 50% of incremental cost Retro-Commissioning: $200,000/year/facility; $100,000/project Leak Survey: $10,000

303

What are the Best HVAC Solutions for Low-Load, High Performance...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

What are the Best HVAC Solutions for Low Load, High Performance Homes? www.BuildingScience.com buildingscience.com...

304

Performance predictions of silica-gel desiccant dehumidifiers  

DOE Green Energy (OSTI)

The analysis of a cross-cooled desiccant dehumidifier using silica gel in the form of sheets is described. This unit is the principal component of solar powered desiccant air conditioning system. The mathematical model has first been formulated describing the dynamics of the dehumidifier. The model leads to a system of nonlinear coupled heat and mass transfer equations for the sorption processes and linear heat transfer equations for the purging processes. The model accounts for the gas film resistance and for the moisture diffusion in the desiccant. The governing equations are solved by a finite difference scheme to obtain periodic steady state solutions. The accuracy of the theoretical predictions is ascertained by comparing them with the experimental results. The performance of the dehumidifier, for a chosen set of initial conditions and dehumidifier parameters, has also been given.

Mathiprakasam, B.; Lavan, Z.

1980-01-01T23:59:59.000Z

305

Experimental investigation of a solar desiccant cooling installation  

Science Conference Proceedings (OSTI)

Desiccant cooling is a technique based on evaporative cooling and air dehumidification using desiccant regenerated by thermal energy. It is particularly interesting when it is driven by waste or solar heat making this technique environmentally friendly. In this paper, an experimental investigation is carried on a desiccant air handling unit powered by vacuum-tube solar collectors. First, the components are studied under various operating conditions. Then overall performance of the installation is evaluated over a day for a moderately humid climate with regeneration solely by solar energy. In these conditions the overall efficiency of the solar installation is 0.55 while the thermodynamic coefficient of performance is 0.45 and the performance indicator based on the electrical consumption is 4.5. Finally, the impact of outside and regeneration conditions on the performance indicators is studied. (author)

Bourdoukan, P.; Wurtz, E. [LOCIE Laboratoire Optimisation de la Conception et Ingenierie de l'Environnement, Campus Scientifique Universite de Savoie, 73376 Le Bourget du Lac (France); Joubert, P. [LEPTIAB Laboratoire d'Etude des Phenomenes de Transfert et de l'Instantaneite Agro-Industrie et Batiment Pole Sciences et Technologies, Universite La Rochelle, Avenue Marillac 17000 La Rochelle (France)

2009-11-15T23:59:59.000Z

306

HVAC equipment replacement for best size and efficiency  

DOE Green Energy (OSTI)

The purpose of this project was to explore the potential benefits of HVAC equipment replacement for buildings owned by the City of Phoenix. The specific research objectives were as follows: Establishment an understanding of the magnitude and sources of saving available through equipment replacement; Establish an economic model for understanding equipment replacement and deciding when equipment should be replaced; Establish technical methods for calculating savings from replacement of various types of equipment; Demonstrate the replacement of a major item of HVAC equipment and document the savings through actual experimentation and measurement; and Provide guidance material for other jurisdictions wishing to investigate equipment replacement. 11 figs., 9 tabs.

Teji, D.S.

1988-02-01T23:59:59.000Z

307

Weather-clustering based strategy design for dynamic demand response building HVAC control  

Science Conference Proceedings (OSTI)

Energy consumption and room temperature can be simulated using EnergyPlus model, given the building model, weather information, and HVAC control strategy. For a given weather forecast, however, online simulation-based optimization of the HVAC control ... Keywords: EnergyPlus, building HVAC control strategy, clustering, dynamic demand response

Rui Liao; Geng Li; Shun Miao; Yan Lu; Jianmin Zhu; Ling Shen

2012-11-01T23:59:59.000Z

308

RF propagation in an HVAC duct system: impulse response characteristics of the channel  

E-Print Network (OSTI)

RF propagation in an HVAC duct system: impulse response characteristics of the channel Pavel V, the heating, ventilation, and air conditioning (HVAC) duct system in buildings is a complex network of hollow at RF and microwave frequencies of com- mon interest. HVAC ducts can be used as a wireless communication

Stancil, Daniel D.

309

BLACK-BOX MODELLING OF HVAC SYSTEM: IMPROVING THE PERFORMANCES OF NEURAL NETWORKS  

E-Print Network (OSTI)

BLACK-BOX MODELLING OF HVAC SYSTEM: IMPROVING THE PERFORMANCES OF NEURAL NETWORKS Eric FOCK Ile de La Réunion - FRANCE ABSTRACT This paper deals with neural networks modelling of HVAC systems of HVAC system can be modelled using manufacturer design data presented as derived performance maps

Paris-Sud XI, Université de

310

Fouling of HVAC Fin and Tube Heat Exchangers Jeffrey Siegel and Van P. Carey  

E-Print Network (OSTI)

LBNL-47668 Fouling of HVAC Fin and Tube Heat Exchangers Jeffrey Siegel and Van P. Carey CIEE ENDORSEMENT OF OR AGREEMENT WITH THESE FINDINGS, NOR THAT OF ANY CIEE SPONSOR. #12;FOULING OF HVAC in residential, commercial and industrial HVAC applications. Invariably, indoor and outdoor air contaminants foul

311

Department of Energy and Mineral Engineering Spring 2013 Solar Innovations -HVAC and Waste Stream Analysis  

E-Print Network (OSTI)

PENNSTATE Department of Energy and Mineral Engineering Spring 2013 Solar Innovations - HVAC and Waste Stream Analysis Overview There are two problems that were voiced by Solar Innovations, HVAC system design and recycling stream improvement. The HVAC system was not providing even conditioning of office

Demirel, Melik C.

312

Automated Testing of HVAC Systems for Commissioning Tim Salsbury and Rick Diamond  

E-Print Network (OSTI)

Automated Testing of HVAC Systems for Commissioning Tim Salsbury and Rick Diamond Lawrence Berkeley of the commissioning of HVAC systems. The approach is based on software that generates a sequence of test signals for new and retrofit projects. Introduction The performance of many HVAC systems is limited more by poor

Diamond, Richard

313

Multi-carrier Signal Transmission through HVAC Ducts: Experimental Results for Channel Capacity  

E-Print Network (OSTI)

Multi-carrier Signal Transmission through HVAC Ducts: Experimental Results for Channel Capacity, for the first time, experimental results on channel capacity of heating, ventilation, and air-conditioning (HVAC through a building HVAC duct system demonstrate the ability to transmit with a spectral efficiency of 3

Stancil, Daniel D.

314

A CONTROLLER FOR HVAC SYSTEMS WITH FAULT DETECTION CAPABILITIES BASED ON SIMULATION MODELS  

E-Print Network (OSTI)

1 A CONTROLLER FOR HVAC SYSTEMS WITH FAULT DETECTION CAPABILITIES BASED ON SIMULATION MODELS T. I describes a control scheme with fault detection capabilities suitable for application to HVAC systems as a reference of correct operation. Faults that occur in the HVAC system under control cause the PI

315

VOLUME 11, NUMBER 2 HVAC&R RESEARCH APRIL 2005 An Optimization-Based Approach for  

E-Print Network (OSTI)

VOLUME 11, NUMBER 2 HVAC&R RESEARCH APRIL 2005 215 An Optimization-Based Approach for Facility formulation and the correspond- ing solution methodology for HVAC systems. The problem is to minimize the energy and demand costs through control of HVAC units while satisfying human comfort, system dynamics

Luh, Peter

316

Seamless Handover in Buildings Using HVAC Ducts: A New System Architecture  

E-Print Network (OSTI)

Seamless Handover in Buildings Using HVAC Ducts: A New System Architecture Ariton E. Xhafa, Paisarn-- In this paper, we present an innovative solution to the handover problem in multi-story buildings using HVAC of the indoor wireless networks that use the heating, ventilation, and air conditioning (HVAC) ducts

Stancil, Daniel D.

317

Tile of the document: HVAC system component-based modeling and implementation  

E-Print Network (OSTI)

1 Abstract Tile of the document: HVAC system component-based modeling and implementation Karam the foundation for modeling components that are used in HVAC systems (heating, ventilation, and air conditioning such functionalities. #12;2 HVAC system component-based modeling and implementation By Karam H. Rajab Scholarly

Austin, Mark

318

Conventional Facilities Chapter 6: HVAC Systems 6-1 NSLS-II Preliminary Design Report  

E-Print Network (OSTI)

Conventional Facilities Chapter 6: HVAC Systems 6-1 NSLS-II Preliminary Design Report 6 MECHANICAL ­ HVAC SYSTEMS 6.1 Design Criteria 6.1.1 Codes and Standards The latest edition of the codes, standards have adequate capacity and head, no chilled water pumps #12;Conventional Facilities Chapter 6: HVAC

Ohta, Shigemi

319

Comparison of dust from HVAC filters, indoor surfaces, and indoor air Federico Noris*  

E-Print Network (OSTI)

Comparison of dust from HVAC filters, indoor surfaces, and indoor air Federico Noris* , Kerry A and Environmental Engineering * Corresponding email: Fedenoris@mail.utexas.edu SUMMARY HVAC filters are long heavy metal (Pb, Cd and As) concentrations. HVAC filter microbial concentrations appear to be consistent

Siegel, Jeffrey

320

VOLUME 16, NUMBER 3 HVAC&R RESEARCH MAY 2010 The Effects of Filtration on  

E-Print Network (OSTI)

VOLUME 16, NUMBER 3 HVAC&R RESEARCH MAY 2010 273 The Effects of Filtration on Pressure Drop and Energy Consumption in Residential HVAC Systems (RP-1299) Brent Stephens Atila Novoselac, PhD Jeffrey A of high-efficiency HVAC filters is a common strategy to control exposure to airborne particulate matter

Siegel, Jeffrey

Note: This page contains sample records for the topic "liquid desiccant hvac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Theoretical Estimates of HVAC Duct Channel Capacity for High-Speed Internet Access  

E-Print Network (OSTI)

Theoretical Estimates of HVAC Duct Channel Capacity for High-Speed Internet Access Ariton E. Xhafa-conditioning (HVAC) ducts based on multi-carrier transmission that uses M-QAM mod- ulation and measured channel- flections in HVAC ducts). Our work also shows that data rates in excess of 300 Mbps are possible over

Stancil, Daniel D.

322

Comparison of HVAC filter test methods for particle removal efficiency Brent Stephens1,*  

E-Print Network (OSTI)

Comparison of HVAC filter test methods for particle removal efficiency Brent Stephens1,* , Jeffrey Introduction The use of HVAC filters in buildings is one strategy to reduce occupant exposure to particulate matter. However, HVAC filters are typically tested only in laboratory settings and little is known about

Siegel, Jeffrey

323

Co-simulation for performance prediction of integrated building and HVAC systems -An analysis of solution  

E-Print Network (OSTI)

Co-simulation for performance prediction of integrated building and HVAC systems - An analysis performance simulation of buildings and heating, ventilation and air- conditioning (HVAC) systems can help, heating, ventilation and air-conditioning (HVAC) systems are responsible for 10%-60% of the total building

324

Advances in open-cycle solid desiccant cooling  

DOE Green Energy (OSTI)

Of the solar cooling options available open cycle solid desiccant cooling looks very promising. A brief review of the experimental and analytical efforts to date shows that within the last 10 years thermal performance has doubled. Research centers have been developed to explore new materials and geometry options and to improve and validate mathematical models that can be used by design engineers to develop new product lines. Typical results from the Solar Energy Research Institute's (SERI) Desiccant Cooling Research Program are shown. Innovative ideas for new cycles and spinoff benefits provide incentives to continue research in this promising field.

Penney, T.R.; Maclaine-cross, I.

1985-05-01T23:59:59.000Z

325

Investigations on Vapour Compression Air Conditioner with Direct Contact Desiccant Loop over Condenser and Evaporator  

E-Print Network (OSTI)

Perceived air quality increases when relative humidity is decreased till about 30% in the range of comfort temperature. In the present scenario, humidity is considered as a pollutant. Hence, a controlled environment not only at low temperature but also at low humidity is desired for many applications such as archives, data centers, etc. Either a separate dehumidifier or a precision air conditioning (AC) system needs to be employed for such an application. In fact, the latter forms a reheat AC system which happens to be energy inefficient. In view of this, a vapor compression window air conditioner is investigated with a superimposed liquid desiccant loop harnessing the advantages of both the compression system (high COP) and desiccant system (low humidity). Operation of such a novel system is explained, elucidating the operational feasibility. The results presented consider the characteristics of such a system with respect to changes in the evaporator inlet air temperature and humidity. The change in the specific humidity of air is compared for vapor compression system and the direct contact hybrid system for different values of inlet air temperature.

Maiya, M. P.; Ravi, J.; Tiwari, S.

2010-01-01T23:59:59.000Z

326

Dehumidification and simultaneous removal of selected pollutants from indoor air by a desiccant wheel using a 1M type desiccant  

SciTech Connect

Solid-desiccant dehumidifiers are increasingly becoming an integral part of desiccant based air-conditioning systems because of their effective handling of latent heat loads compared to conventional vapor compression units. In these units, either a silica gel or a molecular sieve is used for dehumidification of air. Both of them have the capability to co-adsorb various chemical pollutants during dehumidification of air. However, the shape of the isotherm for water vapor on these materials is not favorable for desiccant cooling applications. A mixture (1M desiccant) containing a silica gel, a molecular sieve, and a hydrophobic molecular sieve that was coated on an aluminum foil was studied for its capability for simultaneous removal of moisture and some selected pollutants from air. Experimental data were obtained in a fixed bed adsorber that simulated the operation of a rotary desiccant wheel. Air to be dehumidified and cleaned and the hot regeneration air were cycled in a specific time interval through this bed. The shape of the water isotherm on 1M desiccant was found to be in between that of silica gel and molecular sieve 13{times}, but its uptake capacity was significantly lower than that of either silica gel or molecular sieve. A flow rate of about 100 L/min that provided a face velocity of about 132 cm/s was used in the adsorption step. The flow rate during regeneration was about 50 L/min. The temperature of the inlet air was about 23 C and its relative humidity was varied between 20% and 80%. The concentrations of pollutants were as follows; carbon dioxide: 1050 and 2300 ppm; toluene: 32 ppm; 1,1,1-trichloroethane: 172 ppm, and formaldehyde: 0.35 ppm. A complete breakthrough of all the pollutants was observed during an adsorption cycle.

Popescu, M.; Ghosh, T.K. [Univ. of Missouri, Columbia, MO (United States)

1999-02-01T23:59:59.000Z

327

Validation of a Building Simulation Tool Using Field Data for Three Identical Configuration Full-Serve Restaurants Using Different HVAC Systems  

E-Print Network (OSTI)

A new building application for a pre-existing HVAC software tool which calculates the benefits of desiccant-assisted HVAC equipment versus the performance of a standard vapor-compression system is used to model the monitored results, see Yborra and Spears (2000), for three full-service restaurants. A standard vapor-compression system, an enthalpy assisted vapor-compression system, and a desiccant-assisted vapor-compression system are compared. The vapor-compression portion of each system is comprised of three rooftop units, specifications for each may be found in Yborra and Spears, "Field- Evaluation of Alternative HVAC Strategies to Meet Ventilation, Comfort, and Humidity Control Criteria at Three Full-Serve Restaurants". The software tool uses DOE 2.1E as a calculation engine which runs in the background. Previously, the software tool could model two different hotel configurations, a quickserve restaurant, a supermarket, a retail store, an ice arena, a school, a movie theater, a nursing home and a hospital. With the larger eating area, the full-serve restaurant had the capacity for sensible or enthalpy heat recovery from the exhausted air in the sit-down area. Quick-Serve Restaurants (QSR's) were precluded from these energy saving devices as the exhausted air was heavily laden with grease. Still, even with the kitchen exhausts facing away from the rooftop unit (RTU) intakes, the enthalpy wheels showed noticeable loading from grease. As the field monitoring was performed near Philadelphia, PA, National Renewable Energy Laboratory (NREL) hour-by-hour bin TMY2 meteorological data was used for Philadelphia to model the annual outdoor conditions experienced by each site. Output was provided in the form of humidity bins, monthly energy usage and cost, as well as total annual gas and electric costs. As the fill-serve restaurants were located on the North-Eastem region of the United States, patron comfort was of greater importance to management than annual energy cost savings. Once the model results were determined to properly reflect those of the case studies, the different building equipment types were "moved" around the United States by choosing different bin weather data sets corresponding to Chicago, IL, Atlanta, GA, and Houston, TX. While the default energy rates available in the program are 4 years old, the economic results provide a sound cost comparison.

Brillhart, P. L.; Worek, W. M.

2000-01-01T23:59:59.000Z

328

Performance investigation on a novel two-stage solar driven rotary desiccant cooling system using composite desiccant materials  

Science Conference Proceedings (OSTI)

In this study, a two-stage solar driven rotary desiccant cooling (TSRDC) system with novel configuration and newly developed silica gel-haloid composite desiccant is proposed aiming to reduce regeneration temperature and to achieve high energy performance. Simulated results show that there also exists an optimal rotation speed for TSRDC system. Compared with one-stage system, it is found that for the similar supply air state, the required regeneration temperature of TSRDC system is lower and for the same regeneration temperature, the cooling capacity of TSRDC is bigger. (author)

Ge, T.S.; Li, Y.; Dai, Y.J.; Wang, R.Z. [Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, Shanghai 200240 (China)

2010-02-15T23:59:59.000Z

329

A new modelling methodology to control HVAC systems  

Science Conference Proceedings (OSTI)

Thermal comfort plays an important role in any working environment, but it is a very vague term and it is also very difficult to represent it on modern computers. Its proper definition could be a condition of the mind which expresses satisfaction with ... Keywords: Control, Energy, HVAC, Model, Thermal comfort

José A. Orosa

2011-04-01T23:59:59.000Z

330

Thermovote: participatory sensing for efficient building HVAC conditioning  

Science Conference Proceedings (OSTI)

Thermal comfort has traditionally been measured solely by temperature. While other methods such as Predicted Mean Vote (PMV) are available for measuring thermal comfort, the parameters required for an accurate value are overly complicated to obtain and ... Keywords: HVAC conditioning, PMV, phones, thermal comfort

Varick L. Erickson; Alberto E. Cerpa

2012-11-01T23:59:59.000Z

331

Fuzzy Control of HVAC Systems Optimized by Genetic Algorithms  

Science Conference Proceedings (OSTI)

This paper presents the use of genetic algorithms to develop smartly tuned fuzzy logic controllers dedicated to the control of heating, ventilating and air conditioning systems concerning energy performance and indoor comfort requirements. This problem ... Keywords: HVAC systems, fuzzy logic controllers, genetic tuning, multiple criteria

Rafael Alcalá; Jose M. Benítez; Jorge Casillas; Oscar Cordón; Raúl Pérez

2003-03-01T23:59:59.000Z

332

Solar House Sink Group HVAC System Design Final Report  

E-Print Network (OSTI)

In this project we apply a systems engineering approach to design an intelligent HVAC system. Using sensors and user provided information the systems determines and adjusts the cooling load on the fly to provide the most efficient operation possible, saving energy and money. The system utilizes variable speed drives to provide just enough capacity to keep the indoor

Bob Hayes; Will Seeber; Zhen Zhao; Zhen Kuang; Isr Advisor; Prof Austin; Prof Baras

2011-01-01T23:59:59.000Z

333

HVAC System Design Strategies to Address Indoor Air Quality Standards  

Science Conference Proceedings (OSTI)

This report describes strategies that can be employed in the design and operation of heating, ventilating, and air conditioning (HVAC) systems to address the ASHRAE Standard 62 "Ventilation for Acceptable Indoor Air Quality" requirements. The report examines a wide variety of approaches to meeting the standard and their impact on energy consumption, occupant comfort, and other factors.

1999-12-09T23:59:59.000Z

334

Development of a solar desiccant dehumidifier. Second technical progress report  

SciTech Connect

Research and development of a solar desiccant dehumidifier featuring a rotary bed of granular silica gel and a rotary regenerator for air conditioning is described. The results of the system optimization studies are presented. The studies involved an extensive investigation of the energy saving potential and economic viability of the solar desiccant dehumidifier in different locations in the United States. Conventional electric vapor compression, and solar absorption and Rankine systems also were investigated for comparison. In general, it was found that the solar desiccant equipment, either by itself or in a hybrid system with an electric vapor compression air conditioner, is economically viable for all three locations considered. Substantial energy savings can be effected as well. Seal tests done at AiResearch to develop practical dynamic air seals are described. Leakage and friction tests were performed on a variety of material combinations and configurations. Dacron felt and silicone rubber were found to give an acceptable combination of leakage, friction, and cost characteristics. As part of the commercialization studies for the desiccant equipment, a questionnaire was sent to residential air conditioning equipment distributors. The results of the questionnaire are presented. The specifications and drawings for the 1.5-ton prototype are included. (WHK)

Gunderson, M.E.; Hwang, K.C.; Railing, S.M.; Rousseau, J.

1978-11-10T23:59:59.000Z

335

Energymaster Desiccant System Application to Light Commercial Buildings  

E-Print Network (OSTI)

Desiccant cooling systems offer unique advantages over conventional equipment in certain applications. AskCorp's Energymaster unit has been applied in several commercial situations where these advantages are most significant. The magnitude of operating cost savings and improved control is greatest in humid climates where both ambient enthalpy levels and space latent loads are highest.

Blanpied, M. C.; Coellner, J. A.; Macintosh, D. S.

1987-01-01T23:59:59.000Z

336

High-performance dehumidifier for solar desiccant cooling systems  

DOE Green Energy (OSTI)

An advanced-design, one-tenth-scale dehumidifier for use in residential solar desiccant-cooling systems has been built and tested. The new dehumidifier was designed using a parallel-passage geometry, where air flows through channels formed by walls coated with fine-ground silica gel desiccant. This concept has a high heat and mass transfer effectiveness and promises to double the coefficient of performance of the desiccant cooling system to 1.1 kW cooling output/kW thermal input. The parallel-passage design was found to have very low pressure drop, typically 20 Pa (.08 in. water) at design conditions. The low fan power required to drive such low pressure drop components indicates that electrical COP's in the range of 8.0 to 8.2 kW cooling output/kW electrical input are possible. Results presented include parametric studies of the effect of conditions such as temperature and humidity and design parameters such as desiccant particle size and channel spacing on dehumidifier performance.

Schlepp, D.

1983-05-01T23:59:59.000Z

337

Solar powered desiccant air conditioning system. Final report  

DOE Green Energy (OSTI)

A solar-powered desiccant air conditioning system using silica gel has been developed, and modifications to the existing unit and additional testing are proposed to demonstrate the feasibility of the unit. Conversion from a rotating bed to a fixed bed of silica gel is proposed. Some general plans for commercialization are briefly discussed. (LEW)

Not Available

1981-07-24T23:59:59.000Z

338

Use of unglazed transpired solar collectors for desiccant cooling  

SciTech Connect

The use of unglazed transpired solar collectors for desiccant regeneration in a solid desiccant cooling cycle was investigated because these collectors are less expensive than conventional glazed flat-plate collectors. Using computer models, we studied the performance of a desiccant cooling ventilation cycle integrated with either unglazed transpired collectors or conventional glazed flat-plate collectors. We found that the thermal coefficient of performance of the cooling system with unglazed collectors was lower than that of the cooling system with glazed collectors because the former system did not use the heat of adsorption released during the dehumidification process. Although the area required for the unglazed collector array was 70% more than that required for the glazed collector array in a 10.56 kW (3 ton) solar cooling system, the cost of the unglazed array was 45% less than the cost of the glazed array. The simple payback period of the unglazed collector was half of the payback period of the glazed collector when replacing an equivalent gas-fired air heater. Although the use of unglazed transpired collectors seems to make economic sense relative to use of glazed conventional collectors, some practical considerations may limit their use for desiccant regeneration.

Pesaran, A.A.; Wipke, K.B. (National Renewable Energy Lab., Golden, CO (United States))

1994-05-01T23:59:59.000Z

339

Facility design for cyclic testing of advanced solid desiccant dehumidifiers  

DOE Green Energy (OSTI)

The development of high performance components is required to reach the goal of desiccant cooling system cost-competitiveness with conventional vapor compensation air conditioning systems. SERI has designed a laminar flow, parallel passage dehumidifier that has this potential. The goal of SERI's desiccant cooling research program is to fully characterize experimentally the performance of the parallel passage dehumidifier under a wide range of operating conditions, investigate improvements in design, and verify existing models of dehumidifier performance against experimental results. This report documents the design of the SERI Desiccant Cooling Test Facility for performing the above testing. With slight modifications, the testing can be used for testing other desiccant cooling system components. The dehumidifier processes and the parameters and variables needed to control and characterize its performance are presented. The physical layout of the test loop and instrumentation for monitoring the operating conditions and dehumidifer performance and the controls for maintaining the operating conditions are specified. The computerized data acquisition system conversion equations and an error analysis of measurement variables are also presented.

Schlepp, D.; Schultz, K.; Zangrando, F.

1984-08-01T23:59:59.000Z

340

Energy and economic performance analysis of an open cycle solar desiccant dehumidification air-conditioning system for application in Hong Kong  

Science Conference Proceedings (OSTI)

In this article, a transient simulation model and the EnergyPlus were used to study the energy performance and economical feasibility for integrating a solar liquid desiccant dehumidification system with a conventional vapor compression air-conditioning system for the weather condition of Hong Kong. The vapor compression system capacity in the solar assisted air-conditioning system can be reduced to 19 kW from original 28 kW of a conventional air-conditioning system as a case study due to the solar desiccant cooling. The economical performance of the solar desiccant dehumidification system is compared with that of the conventional air-conditioning system. The results show that the energy saving potentials due to incorporation of the solar desiccant dehumidification system in a traditional air-conditioning system is significant for the hot wet weather in Hong Kong due to higher COP resulted from higher supply chilled water temperature from chiller plants. The annual operation energy savings for the hybrid system is 6760 kWh and the payback period of the hybrid system is around 7 years. The study shows that the solar assisted air-conditioning is a viable technology for utilizations in subtropical areas. (author)

Li, Yutong; Lu, Lin; Yang, Hongxing [Renewable Energy Research Group (RERG), Department of Building Services Engineering, Hong Kong Polytechnic University, Hung Hom (China)

2010-12-15T23:59:59.000Z

Note: This page contains sample records for the topic "liquid desiccant hvac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Ventilation, temperature, and HVAC characteristics in small and medium  

NLE Websites -- All DOE Office Websites (Extended Search)

Ventilation, temperature, and HVAC characteristics in small and medium Ventilation, temperature, and HVAC characteristics in small and medium commercial buildings in California Title Ventilation, temperature, and HVAC characteristics in small and medium commercial buildings in California Publication Type Journal Article Refereed Designation Refereed Year of Publication 2012 Authors Bennett, Deborah H., William J. Fisk, Michael G. Apte, X. Wu, Amber L. Trout, David Faulkner, and Douglas P. Sullivan Journal Indoor Air Volume 22 Issue 4 Pagination 309-20 Abstract This field study of 37 small and medium commercial buildings throughout California obtained information on ventilation rate, temperature, and heating, ventilating, and air-conditioning (HVAC) system characteristics. The study included seven retail establishments; five restaurants; eight offices; two each of gas stations, hair salons, healthcare facilities, grocery stores, dental offices, and fitness centers; and five other buildings. Fourteen (38%) of the buildings either could not or did not provide outdoor air through the HVAC system. The air exchange rate averaged 1.6 (s.d. = 1.7) exchanges per hour and was similar between buildings with and without outdoor air supplied through the HVAC system, indicating that some buildings have significant leakage or ventilation through open windows and doors. Not all buildings had sufficient air exchange to meet ASHRAE 62.1 Standards, including buildings used for fitness centers, hair salons, offices, and retail establishments. The majority of the time, buildings were within the ASHRAE temperature comfort range. Offices were frequently overcooled in the summer. All of the buildings had filters, but over half the buildings had a filter with a minimum efficiency reporting value rating of 4 or lower, which are not very effective for removing fine particles. PRACTICAL IMPLICATIONS: Most U.S. commercial buildings (96%) are small- to medium-sized, using nearly 18% of the country's energy, and sheltering a large population daily. Little is known about the ventilation systems in these buildings. This study found a wide variety of ventilation conditions, with many buildings failing to meet relevant ventilation standards. Regulators may want to consider implementing more complete building inspections at commissioning and point of sale.

342

This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (http://www.hvac.okstate.edu).  

E-Print Network (OSTI)

at Oklahoma State University (http://www.hvac.okstate.edu). The correct citation for the paper is: Spitler, J.D. 2007. Research Planning for the HVAC&R Industry. HVAC&R Research 13(5):681- 682. #12;VOLUME 13, NUMBER 5 HVAC&R RESEARCH SEPTEMBER 2007 681 EDITORIAL Research Planning for the HVAC&R Industry Jeffrey D

343

HVAC Radial Air Bearing Heat Exchangers Research Project | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Radial Air Bearing Heat Exchangers Radial Air Bearing Heat Exchangers Research Project HVAC Radial Air Bearing Heat Exchangers Research Project The U.S. Department of Energy is currently conducting research into heating, ventilation, and air conditioning (HVAC) radial air bearing heat exchangers. Rotary air bearing heat exchanger technology simultaneously solves four long standing problems of conventional "fan-plus-finned-heat-sink" heat exchangers. Project Description This project seeks to design, fabricate, and test successive generations of prototype radial air bearing heat exchanger devices based on lessons learned and further insights into device optimization, computational fluid dynamic studies for parametric optimization and determination of scaling laws, and laboratory measurement of flow field and heat transfer

344

Optimizing HVAC Control to Improve Building Comfort and Energy Performance  

E-Print Network (OSTI)

This paper demonstrates the benefits of optimal control in well-designed and operated buildings using a case study. The case study building was built in 2001. The HVAC and control systems have been installed with state-of-the-art equipment which include a terminal box temperature integrated minimum airflow reset. The building has been used and operated based on the design intents. This paper presents both the existing and the optimal control schedules, which include the VAV box operation schedule, AHUs optimal control, chiller and chilled water pump control, and boiler and hot water pump control. The measured hourly HVAC electricity consumption shows that annual savings of up to 40% can be achieved with an optimal control schedule.

Song, L.; Joo, I.; Dong, D.; Liu, M.; Wang, J.; Hansen, K.; Quiroz, L.; Swiatek, A.

2003-01-01T23:59:59.000Z

345

Quantitative Methods for Comparing Different HVAC Control Schemes  

E-Print Network (OSTI)

Experimentally comparing the energy usage and comfort characteristics of different controllers in heating, ventilation, and air-conditioning (HVAC) systems is difficult because variations in weather and occupancy conditions preclude the possibility of establishing equivalent experimental conditions across the order of hours, days, and weeks. This paper is concerned with defining quantitative metrics of energy usage and occupant comfort, which can be computed and compared in a rigorous manner that is capable of determining whether differences between controllers are statistically significant in the presence of such environmental fluctuations. Experimental case studies are presented that compare two alternative controllers (a schedule controller and a hybrid system learning-based model predictive controller) to the default controller in a building-wide HVAC system. Lastly, we discuss how our proposed methodology may also be able to quantify the efficiency of other building automation systems.

Aswani, Anil; Taneja, Jay; Krioukov, Andrew; Culler, David; Tomlin, Claire

2012-01-01T23:59:59.000Z

346

Plutonium Finishing Plant (PFP) HVAC System Component Index  

SciTech Connect

This document lists safety class (SC) and safety significant (SS) components for the Heating Ventilation Air Conditioning (HVAC) and specifies the critical characteristics for Commercial Grade Items (CGI), as required by HNF-PRO-268 and HNF-PRO-18 19. These are the minimum specifications that the equipment must meet in order to properly perform its safety function. There may be several manufacturers or models that meet the critical characteristics for any one item. The Plutonium Finishing Plant (PFP) HVAC System includes sub-systems 25A through 25K. Specific system boundaries and justifications are contained in HNF-SD-CP-SDD-005, ''Definition and Means of Maintaining the Ventilation System Confinement Portion of the PFP Safety Envelope.'' The procurement requirements associated with the system necessitates procurement of some system equipment as Commercial Grade Items in accordance with HNF-PRO-268, ''Control of Purchased Items and Services.''

DIAZ, E.N.

2000-03-30T23:59:59.000Z

347

HVAC Optimized Heat Exchangers Research Project | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Optimized Heat Exchangers Research Optimized Heat Exchangers Research Project HVAC Optimized Heat Exchangers Research Project The U.S. Department of Energy is currently conducting research into heating, ventilation, and air conditioning (HVAC) optimized heat exchangers. The information generated in this study will demonstrate performance improvements that can be achieved through optimization of refrigerant circuitry for non-uniform inlet air distribution. The tubing circuitry on fin-tube heat exchangers used in residential space-conditioning systems is typically designed assuming uniform airflow through the finned passageways. However, the air flow in installed systems is highly non-uniform, resulting in mismatched refrigerant-air heat transfer that reduces the capacity of the heat exchanger and efficiency of

348

Outdoor airflow into HVAC systems: An evaluation of measurement  

NLE Websites -- All DOE Office Websites (Extended Search)

Outdoor airflow into HVAC systems: An evaluation of measurement Outdoor airflow into HVAC systems: An evaluation of measurement technologies Title Outdoor airflow into HVAC systems: An evaluation of measurement technologies Publication Type Report LBNL Report Number LBNL-53834 Year of Publication 2003 Authors Fisk, William J., David Faulkner, Douglas P. Sullivan, and William W. Delp Abstract During the last few years, new technologies have been introduced for measuring the flow rates of outdoor air (OA) into HVAC systems; however, an evaluation of these measurement technologies has not previously been published. This document describes a test system and protocols developed for controlled evaluation of these measurement technologies. The results of tests of three measurement technologies are also summarized. The test system and protocol were judged practical and very useful. The test results indicate that one measurement technology can measure OA flow rates with errors of 20% or less without a field-based calibration, as long as the OA velocities are sufficient to provide an accurately measurable pressure signal. The test results for a second measurement technology are similar; however, a difficult field-based calibration relating the OA flow rate with the pressure signal would be required to reduce errors below approximately 30%. The errors in OA flow rates measured with the third measurement technology, that uses six electronic airspeed sensors downstream of the OA inlet louver, exceeded 100%; however, these errors could be substantially reduced through a difficult field based calibration. The effects of wind on the accuracy of these measurement technologies still needs to be evaluated

349

Indoor Air Quality Primer for HVAC System Design  

Science Conference Proceedings (OSTI)

Heating, ventilating, and air conditioning (HVAC) systems are major energy users in commercial and institutional buildings. Increased ventilation for acceptable indoor air quality (IAQ), besides increasing energy use, may result in unacceptably high indoor humidity, particularly in humid climates and/or applications requiring high ventilation rates. This report analyzes how increased ventilation affects the dehumidification capabilities of air conditioning systems in three applications -- offices, retail...

2002-02-21T23:59:59.000Z

350

Computer program for conducting acoustical analyses of HVAC systems.  

Science Conference Proceedings (OSTI)

An interactive Windows?based computer program has been developed that can be used to conduct complete acoustical analyses of HVAC systems. The program can be used to track sound from a HVACsound source such as a fan to a room. Both sound from a single path between a sound source and room or from multiple paths between a sound source and room can be investigated. The program has a full set of editing features that include change

Douglas D. Reynolds; Scott C. Mitchell

1996-01-01T23:59:59.000Z

351

STANDARDS CONTROLLING AIR EMISSIONS FOR THE SOIL DESICCATION PILOT TEST  

Science Conference Proceedings (OSTI)

This air emissions document supports implementation of the Treatability Test Plan for Soil Desiccation as outlined in the Deep Vadose Zone Treatability Test Plan for the Hanford Central Plateau (DOE/RL-2007-56). Treatability testing supports evaluation of remedial technologies for technetium-99 (Tc-99) contamination in the vadose zone at sites such as the BC Cribs and Trenches. Soil desiccation has been selected as the first technology for testing because it has been recommended as a promising technology in previous Hanford Site technology evaluations and because testing of soil desiccation will provide useful information to enhance evaluation of other technologies, in particular gas-phase remediation technologies. A soil desiccation pilot test (SDPT) will evaluate the desiccation process (e.g., how the targeted interval is dried) and the long-term performance for mitigation of contaminant transport. The SDPT will dry out a moist zone contaminated by Tc-99 and nitrate that has been detected at Well 299-E13-62 (Borehole C5923). This air emissions document applies to the activities to be completed to conduct the SDPT in the 200-BC-1 operable unit located in the 200 East Area of the Hanford Site. Well 299-E13-62 is planned to be used as an injection well. This well is located between and approximately equidistant from cribs 216-B-16, 216-B-17, 216-B-18. and 216-B-19. Nitrogen gas will be pumped at approximately 300 ft{sup 3}/min into the 299-EI3-62 injection well, located approximately 12 m (39 ft) away from extraction well 299-EI3-65. The soil gas extraction rate will be approximately 150 ft{sup 3}/min. The SDPT will be conducted continuously over a period of approximately six months. The purpose of the test is to evaluate soil desiccation as a potential remedy for protecting groundwater. A conceptual depiction is provided in Figure 1. The soil desiccation process will physically dry, or evaporate, some of the water from the moist zone of interest. As such, it is expected that Tc-99 and nitrate will remain with the water residual that is not removed, or remain as a salt bound to the soil particles. In addition, the SDPT will be conducted at lower extraction velocities to preclude pore water entrainment and thus, the extracted air effluent should be free of the contaminant residual present in the targeted moist zone. However, to conservatively bound the planned activity for potential radionuclide air emissions, it is assumed, hypothetically, that the Tc-99 does not remain in the zone of interest, but that it instead travels with the evaporated moisture to the extraction well and to the test equipment at the land surface. Thus, a release potential would exist from the planned point source (powered exhaust) for Tc-99 in the extracted moist air. In this hypothetical bounding case there would also be a potential for very minor fugitive emissions to occur due to nitrogen injection into the soil. The maximum value for Tc-99, measured in the contaminated moist zone, is used in calculating the release potential described in Section 2.3. The desiccation mechanism will be evaporation. Nitrate is neither a criteria pollutant nor a toxic air pollutant. It would remain nitrate as a salt adhered to sand and silt grains or as nitrate dissolved in the pore water. Nitrogen, an inert gas, will be injected into the ground during the test. Tracer gasses will also be injected near the beginning, middle, and the end of the test. The tracer gasses are sulfur hexafluoride, trichlorofluoromethane, and difluoromethane.

BENECKE MW

2010-09-08T23:59:59.000Z

352

Performance of a cross-cooled desiccant dehumidifier prototype  

DOE Green Energy (OSTI)

The cross-cooled dehumidifier prototype was constructed in the form of a cube with a side dimension of 0.6 m. The cross-cooling was achieved by passing air through rectangular channels perpendicular to process channels which are lined with desiccant sheets consisting of 9..mu..m Syloid 63/sup TM/ silica gel held in a Teflon web. The process for the manufacture of the silica gel sheets was developed at the Illinois Institute of Technology. The dehumidifier prototype was installed in a test system that simulated the performance of a cross-cooled desiccant cooling system and monitored the performance of the prototype. The dehumidifier prototype was operated over a wide range of operating conditions which would be typically encountered in the field installation of such a system. Variables measured were the moisture cycled, cooling capacity, total cooling capacity and coefficient of performance.

Worek, W.M.; Lavan, Z.

1981-08-01T23:59:59.000Z

353

Desiccant grain applied to the storage of solar drying potential  

Science Conference Proceedings (OSTI)

Sorption storage of solar heat using a layer of wheat as the desiccant was analyzed by means of a deep-bed model. Intended to be applied to solar-assisted in-storage drying of agricultural bulk materials, the probability of the persistence of unfavorable weather periods was quantified statistically for Potsdam for the month of August, as an example. Simulation results demonstrate that a relative humidity of the drying air of 65% can be maintained day and night for weeks without combustion of fossil fuels. Using a simple strategy of control, periods with insufficient solar radiation can be bridged over. The desiccant grain is not endangered by mold growth as a matter of principle. Simple solar air heaters can be used to avoid economic losses due to overdrying and to reduce the danger of decay to a minimum even at unfavorable climatic conditions.

Ziegler, T.; Richter, I.G.; Pecenka, R.

1999-09-01T23:59:59.000Z

354

Test and Evaluation of a Hybrid Desiccant Dehumidifier  

Science Conference Proceedings (OSTI)

Dehumidification technology is being investigated for potential savings in building air conditioning systems. The potential for savings lies in separating the sensible and the latent cooling loads to more efficiently address the combined conditioning needs of the space. The Munters DryCool HD combined desiccant/vapor compression system was tested in the EPRI Knoxville psychrometric chambers. The system was tested in the laboratory for a host of indoor and outdoor conditions. The system provides cooling a...

2011-05-09T23:59:59.000Z

355

Development and Analysis of Desiccant Enhanced Evaporative Air Conditioner Prototype  

SciTech Connect

This report documents the design of a desiccant enhanced evaporative air conditioner (DEVAP AC) prototype and the testing to prove its performance. Previous numerical modeling and building energy simulations indicate a DEVAP AC can save significant energy compared to a conventional vapor compression AC (Kozubal et al. 2011). The purposes of this research were to build DEVAP prototypes, test them to validate the numerical model, and identify potential commercialization barriers.

Kozubal, E.; Woods, J.; Judkoff, R.

2012-04-01T23:59:59.000Z

356

Two Alabama Elementary Schools Get Cool with New HVAC Units | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Alabama Elementary Schools Get Cool with New HVAC Units Alabama Elementary Schools Get Cool with New HVAC Units Two Alabama Elementary Schools Get Cool with New HVAC Units October 1, 2010 - 2:05pm Addthis Winston County School District will receive 14 new HVAC units with State Energy Program funding. | File photo Winston County School District will receive 14 new HVAC units with State Energy Program funding. | File photo Lindsay Gsell What are the key facts? Two public elementary schools receive 14 new HVAC units for classrooms. School district estimates nearly 10 percent in electrical savings with new units. Nineteen Alabama public school districts using Recovery Act grants to save energy and money. Addison Elementary School and Double Springs Elementary School in northwestern Alabama were warm. Some classrooms just didn't cool fast enough. The buildings, which were

357

Analysis of a Fabric/Desiccant Window Cavity Dehumidifier  

E-Print Network (OSTI)

This paper presents the results of an exploratory study of a fabric/desiccant window cavity dehumidifier system for possible use in commercial buildings. The objective was to evaluate fabrics commonly used in buildings, and system concepts that employ these fabrics, which can be used to dehumidify room air. We developed a first-order energy/mass balance model to determine the performance of a window cavity dehumidifier that uses silica gel encapsulated in a fabric matrix rotating on a belt alternately through dehumidification and regeneration chambers; the modeling effort was supplemented by environmental chamber measurements of the moisture absorption characteristics of 16 fabric/desiccant combinations. We ran the model for a typical office building module, for outside air design conditions characteristic of the most difficult humidity regime in Texas. Two flow configurations, outside air and return air, were evaluated to determine the capability of such a system to dehumidify the air streams under consideration. Issues addressed included the physical limitations on the amount of desiccant that can be included in this configuration and the degree of dehumidification achievable.

Hunn, B. D.; Grasso, M. M.; Vadlamani, V.

1994-01-01T23:59:59.000Z

358

Development of an Energy Efficient Desiccant Dehumidifier : Final Report.  

SciTech Connect

Humidity control in space conditioning has received a good deal of attention in the past twenty or so years. Perhaps the most familiar application is the use of humidifiers in the winter months. Of equal concern is the use of air conditions and dehumidifiers in the summer months. High humidity levels in summer months require lower coil temperatures in order to achieve human comfort levels, and may result in significant product and property damage if humidity levels are not controlled at appropriate level. This study addresses the solid desiccant dehumidifier using IR heaters as an energy efficient desiccant dehumidifier (EEDD). The study is divided into two phases; Phase 1 -- Application assessment; and Phase 2: Prototype design, manufacture, and testing. Phase 1 addresses the total electrical energy usage by all possible applications of the EEDD and evaluates the energy performance of the EEDD in terms of its percentage energy savings compared to the conventional vapor compression cooling and also with the state-of-the-art desiccant dehumidifiers. During Phase 2, a functional EEDD prototype unit was designed and manufactured. The work of Phase 2 was divided into four tasks: Task 1, conceptual design; Task 2, mechanical (blueprint) design; Task 3, manufacture and factory testing; and Task 4, performance testing. 17 refs., 21 figs., 30 tabs.

Relwani, Suresh M.; Moschandreas, Demetrios J.

1990-04-01T23:59:59.000Z

359

Analysis of various designs of a desiccant wheel for improving the performance using a mathematical model  

Science Conference Proceedings (OSTI)

A mathematical model for predicting the performance of a desiccant wheel with various wheel designs has been used by considering heat and mass transfer for both moist air and the desiccant material. The model shows good agreement with experimental data. An experimental setup was fabricated using an evacuated tube solar air collector with a desiccant wheel. The hot air needed for regeneration is produced by the evacuated tube solar air collector

Avadhesh Yadav; V. K. Bajpai

2013-01-01T23:59:59.000Z

360

Method and composition for molding low density desiccant syntactic foam articles  

DOE Patents (OSTI)

A method and a composition are provided for molding low density desiccant syntactic foam articles. A low density molded desiccant article may be made as a syntactic foam by blending a thermosetting resin, microspheres and molecular sieve desiccant powder, molding and curing. Such articles have densities of 0.2-0.9 g/cc, moisture capacities of 1-12% by weight, and can serve as light weight structural supports.

Lula, James W. (Bonner Springs, KS); Schicker, James R. (Lee' s Summit, MO)

1984-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "liquid desiccant hvac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Best Practices for Energy Efficient Cleanrooms Efficient HVAC Systems: Variable-Speed-Drive Chillers  

E-Print Network (OSTI)

the portion of chiller energy usage was significant. It is,Figure 1. Benchmarked HVAC energy usages in a semiconductor2. Benchmarked cleanroom energy usages in a semiconductor

Xu, Tengfang

2005-01-01T23:59:59.000Z

362

HVAC Right-Sizing Part 1-Calculating Loads | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

-Calculating Loads HVAC Right-Sizing Part 1-Calculating Loads During this webinar, Building America Research Team IBACOS highlighted the key criteria required to create accurate...

363

Energy and Cost Implications of the Florida Energy Star Residential HVAC Rebate Program.  

E-Print Network (OSTI)

??In July 2010, the Florida’s Governors Energy Office released the Florida ENERGY STAR Residential HVAC Rebate Program. The program was funded by a grant from… (more)

Strauss, Kurt

2012-01-01T23:59:59.000Z

364

Design Analysis and Experimental Investigation of the HVAC System in an IC Circuit Plant.  

E-Print Network (OSTI)

??It is the goal of this project to investigate the energy conservation measures which can be adapted in an electronic manufacturing plant HVAC system. Computer… (more)

Chang, I-wei

2005-01-01T23:59:59.000Z

365

REDESIGN OF HVAC SYSTEM TO IMPROVE ENERGY EFFICIENCY OF EDUCATIONAL BUILDING.  

E-Print Network (OSTI)

??An energy modeling software was used to analyze the current building configuration and simulations were performed in an attempt to redesign the current HVAC system… (more)

Hagene, Brian Matthew

2012-01-01T23:59:59.000Z

366

Quiet unlined HVAC ductwork: Using active silencing to obtain NC?35 in buildings without fibrous materials  

Science Conference Proceedings (OSTI)

Fan noise in HVAC ducts has traditionally been attenuated with fibrous internal duct liner or with passive silencers constructed with porous fill material. Now

Steve Wise; Lawrence J. Gelin; Kirk G. Burlage; Susan H. Dineen

1995-01-01T23:59:59.000Z

367

HVAC Right-Sizing Part 1: Calculating Loads | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

: Calculating Loads HVAC Right-Sizing Part 1: Calculating Loads This webinar, presented by IBACOS (a Building America Research Team) will highlight the key criteria required to...

368

Numerical Investigation of Flow Induced Noise in a Simplified HVAC Duct with OpenFOAM.  

E-Print Network (OSTI)

?? Due to the growing demand for comfort, the noise generated by HVAC components should be considered by the designers. Flow induced noise is one… (more)

Wang, Cong

2013-01-01T23:59:59.000Z

369

Tecniche di machine learning per la ricerca guasti in impianti HVAC.  

E-Print Network (OSTI)

??Il corretto funzionamento degli impianti di tipo HVAC (Heating Ventilating and Air Conditioning) di taglia medio/grande, risulta cruciale al fine di garantire un adeguato livello… (more)

Corso, Lorenzo

2012-01-01T23:59:59.000Z

370

Dynamic modeling and global optimal operation of multizone variable air volume HVAC systems.  

E-Print Network (OSTI)

??Energy conservation and indoor environment concerns have motivated extensive research on various aspects of control of Heating, Ventilating and Air-Conditioning (HVAC) and building systems. The… (more)

Zheng, Guo Rong

1997-01-01T23:59:59.000Z

371

Analysis and modelling of membrane heat exchanger in HVAC energy recovery systems.  

E-Print Network (OSTI)

??The performance of membrane heat exchangers for HVAC total energy recovery systems was evaluated through experimentation and detailed system modelling. The operating principle of the… (more)

Nasif, Mohammad Shakir

2008-01-01T23:59:59.000Z

372

On the use of the parabolic concentration profile assumption for a rotary desiccant dehumidifier  

SciTech Connect

The current work describes a model for a desiccant dehumidifier which uses a parabolic concentration profile assumption to model the diffusion resistance inside the desiccant particle. The relative merits of the parabolic concentration profile model compared with widely utilized rotary desiccant wheel models are discussed. The periodic steady-state parabolic concentration profile model developed is efficient and can accommodate a variety of materials. These features make it an excellent tool for design studies requiring repetitive desiccant wheel simulations. A quartic concentration profile assumption was also investigated which yielded a 2.8 percent average improvement in prediction error over the parabolic model.

Chant, E.E. [Univ. of Turabo, Gurabo (Puerto Rico); Jeter, S.M. [Georgia Inst. of Technology, Atlanta, GA (United States). George W. Woodruff School of Mechanical Engineering

1995-02-01T23:59:59.000Z

373

Analytical investigation of the desiccant enhanced nocturnal radiation cooling concept. Final report  

DOE Green Energy (OSTI)

A new concept in desiccant cooling called desiccant enhanced nocturnal radiation is proposed. The concept employs the roof of a typical residential building to act as a heat dissipator for the energy of sorption produced by a desiccant bed during a nightly adsorption cycle. During the day ambient air and solar radiation absorbed by the roof are used to regenerate the desiccant. The residence is assumed to contain the necessary thermal and moisture storage capacity to take advantage of the daily cycle. This report presents results of an analytical investigation of the adsorption and desorption cycles of the proposed concept using detailed finite element and boundary element modeling techniques.

Fairey, P.; Kerestecioglu, A.; Vieira, R.

1986-04-30T23:59:59.000Z

374

Assessment of organic compound exposures, thermal comfort parameters, and HVAC system-driven air exchange rates in public school portable classrooms in California  

E-Print Network (OSTI)

SPECIFY UNITS) when heat (of HVAC) is turned off?using the heat (from HVAC)? A. B. C. D. January Februaryair conditionmg (from HVAC)? A. B. C. D. January February

Shendell, Derek Garth

2010-01-01T23:59:59.000Z

375

Procedures to identify Energy Conservation Opportunities applied to HVAC system: example of VSD of chilled water pumps  

E-Print Network (OSTI)

Procedures to identify Energy Conservation Opportunities applied to HVAC system: example of VSD of HVAC equipment using variable speed drive (VSD) is an Energy Conservation Opportunity (ECO) which can

Paris-Sud XI, Université de

376

Source attenuating HVAC equipment—Just the facts  

Science Conference Proceedings (OSTI)

Current classroom designs range from NC 63 to NC 25. The ASA/ANSI 12.60 Classroom Standard sets a relatively low background sound requirement for classrooms. Achieving 12.60 levels economically requires the maximum in source sound attenuation. This paper will provide a manufacturer’s perspective on current and low noiseHVAC products and the resulting classroomsound levels. Predictive acoustics software will be used to predict the space sound power level and some indication of equipment cost will be provided in order to assist designers in what is the best approach to low noiseclassroom design.

2004-01-01T23:59:59.000Z

377

Creating a Virtual HVAC Laboratory for Continuing/Distance Education  

E-Print Network (OSTI)

Facilities engineering is one technical field where lab-based continuing education programs can be delivered in a distance learning format. The widespread use of computer controls for optimizing the efficiency of a building's mechanical and electrical systems has made the "distance" element possible. Rather than traveling to individual buildings to make pressure, temperature, and flow measurements in person, facility engineers routinely access performance data over the Internet. This networking capability has been used in an educational setting to deliver interactive technical training to large numbers of undergraduate students and professional facilities engineers. Many students can access real time data from a single piece of HVAC equipment over the Internet.

William J. Hutzel

2001-01-01T23:59:59.000Z

378

ZonePAC: Zonal Power Estimation and Control via HVAC Metering and Occupant Feedback  

Science Conference Proceedings (OSTI)

Heating Ventillation and Air Conditioning (HVAC) systems account for nearly 40% of primary energy consumption by commercial buildings. Yet, these systems by and large operate in an open-loop with the building occupants. While the monitoring and feedback ... Keywords: Energy Estimation, HVAC, Thermostat, User Interface, Variable Air Volume

Bharathan Balaji, Hidetoshi Teraoka, Rajesh Gupta, Yuvraj Agarwal

2013-11-01T23:59:59.000Z

379

An "ageing" operator and its use in the highly constrained topological optimization of HVAC system design  

Science Conference Proceedings (OSTI)

The synthesis of novel heating, ventilating, and air-conditioning (HVAC), system configurations is a mixed-integer, non-linear, highly constrained, multi-modal, optimization problem, with many of the constraints being subject to time-varying boundary ... Keywords: HVAC, evolutionary algorithms, system design, topological optimization

Jonathan Wight; Yi Zhang

2005-06-01T23:59:59.000Z

380

Co-design of control algorithm and embedded platform for building HVAC systems  

Science Conference Proceedings (OSTI)

The design of heating, ventilation and air conditioning (HVAC) systems is crucial for reducing energy consumption in buildings. As complex cyber-physical systems, HVAC systems involve three closely-related subsystems -- the control algorithm, the physical ... Keywords: building energy efficiency, co-design, platform-based design

Mehdi Maasoumy, Qi Zhu, Cheng Li, Forrest Meggers, Alberto Sangiovanni-Vincentelli

2013-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "liquid desiccant hvac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Airborne Particulate Matter in HVAC Systems and its Influence on Indoor Air Quality  

E-Print Network (OSTI)

This paper first reviews the mechanisms governing movement of PMs in HVAC systems. Then, the basic equations governing PM deposition in ducts are introduced and investigations on airborne PMs distribution in HVAC systems are reviewed. The influence of PMs on indoor air quality and effectiveness of corresponding controlling measures is discussed extensively in the paper. Finally, recommendations for further research are given.

Fu, Z.; Li, N.; Wang, H.

2006-01-01T23:59:59.000Z

382

Review of Pre- and Post-1980 Buildings in CBECS - HVAC Equipment  

SciTech Connect

PNNL was tasked by DOE to look at HVAC systems and equipment for Benchmark buildings based on 2003 CBECS data. This white paper summarizes the results of PNNL’s analysis of 2003 CBECS data and provides PNNL’s recommendations for HVAC systems and equipment for use in the Benchmark buildings.

Winiarski, David W.; Jiang, Wei; Halverson, Mark A.

2006-12-01T23:59:59.000Z

383

Feasibility of retrofitting centralized HVAC systems for room-level zoning  

Science Conference Proceedings (OSTI)

Heating, ventilation, and cooling (HVAC) accounts for 38% of building energy usage, and over 15% of all US energy usage, making it one of the nation's largest energy consumers. Many attempts have been made to optimize the control of HVAC systems by minimizing ... Keywords: sensing,Building energy,wireless sensor networks

Tamim Sookoor; Brian Holben; Kamin Whitehouse

2012-06-01T23:59:59.000Z

384

Proposal for the Award of a Contract for Maintenance, Operation and Minor Installation Work for CERN Cooling and HVAC Systems  

E-Print Network (OSTI)

Proposal for the Award of a Contract for Maintenance, Operation and Minor Installation Work for CERN Cooling and HVAC Systems

1996-01-01T23:59:59.000Z

385

Development of New HVAC Design Tools: Search for the Holy Grail of  

NLE Websites -- All DOE Office Websites (Extended Search)

Development of New HVAC Design Tools: Search for the Holy Grail of Development of New HVAC Design Tools: Search for the Holy Grail of Ventilation Research Speaker(s): Jelena Srebric Date: January 29, 2004 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: William Fisk HVAC systems are very important to our wellbeing, energy, and the environment. Current design tools are typically supported by basic knowledge, and keep us at arm's length from the many practical problems. The design paradigm has been shifted several times in the past from thermal comfort, energy conservation, health concerns, and now probably to security issues. Each of the shift has required better design tools of HVAC systems.A team led by Dr. Jelena Srebric at the Department of Architecture, the Penn State University (PSU) is developing new HVAC design tools to meet

386

Direct Digital Control- A Tool for Energy Management of HVAC Systems  

E-Print Network (OSTI)

Direct digital control (DDC) applied to heating, ventilating, and air-conditioning (HVAC) systems corrects many of the deficiencies of conventional automatic temperature control systems. By applying new control sequences, DDC optimizes HVAC energy use. DDC can reduce HVAC operation and maintenance time and provide the environmental conditions needed to maximize production. DDC technology uses standalone, microprocessor based controllers. Controllers directly sense and process control variables (e.g. temperature, pressure) and provide a control signal to an actuator. Personal computers provide remote or local access to the digital controllers and give HVAC mechanics, energy managers, and facility engineers capabilities that conventional control systems do not offer. This paper discusses the most common deficiencies of conventionally controlled HVAC systems, advantages of DOC systems, and a case study retrofit from pneumatic control to digital control.

Swanson, K.

1993-03-01T23:59:59.000Z

387

Proceedings of Healthy Buildings 2009 Paper 535 HVAC filters as "passive" samplers: fate analysis of indoor particles  

E-Print Network (OSTI)

Proceedings of Healthy Buildings 2009 Paper 535 HVAC filters as "passive" samplers: fate analysis: fedenoris@mail.utexas.edu SUMMARY To assess the potential use of HVAC filters as passive indoor samplers, exfiltration, and capture in the HVAC filter. The results suggest that large particles are likely to deposit

Siegel, Jeffrey

388

Simulation of Control Options for HVAC Management of a Typical Office Julien CAILLET julien.caillet@mines-paristech.fr  

E-Print Network (OSTI)

Simulation of Control Options for HVAC Management of a Typical Office Building. Julien CAILLET thermal comfort and to reduce energy consumption of buildings. Among defect correction, HVAC control appears as a way of significant improvement. HVAC control is examined by using a dynamic simulation

Paris-Sud XI, Université de

389

7/11/00-draft copy: do not quote 1 of 30 New Technologies for Residential HVAC Ducts  

E-Print Network (OSTI)

7/11/00-draft copy: do not quote 1 of 30 New Technologies for Residential HVAC Ducts Burke Treidler is not evaluated and HVAC contractors overcome duct system shortcomings by installing oversized equipment Technologies for Residential HVAC Ducts fittings with some use of ductboard. Fittings that snap together were

390

IEEE TRANSACTIONS ON COMMUNICATIONS, VOL. 53, NO. 2, FEBRUARY 2005 335 On the Capacity Limits of HVAC Duct Channel for  

E-Print Network (OSTI)

of HVAC Duct Channel for High-Speed Internet Access Ariton E. Xhafa, Member, IEEE, Ozan K. Tonguz, Member and experimental channel-capacity estimates of heating, ventilation, and air condi- tioning (HVAC) ducts based suppressed. Our experimental results also show that even in the case of more complex HVAC duct networks (i

Stancil, Daniel D.

391

1736 IEEE TRANSACTIONS ON COMMUNICATIONS, VOL. 51, NO. 10, OCTOBER 2003 Impulse Response of the HVAC Duct as a  

E-Print Network (OSTI)

of the HVAC Duct as a Communication Channel Pavel V. Nikitin, Member, IEEE, Daniel D. Stancil, Senior Member (HVAC) ducts in buildings behave as multimode waveguides when excited at radio frequencies and thus, can of a usual indoor propagation channel. In this paper, we describe physical mechanisms which affect the HVAC

Hochberg, Michael

392

ETME 422 -REFRIGERATION & HVAC SYSTEMS FALL 2011 LEC -10:00 -10:50am M W F RH 312  

E-Print Network (OSTI)

10/31/2011 ETME 422 - REFRIGERATION & HVAC SYSTEMS FALL 2011 LEC - 10:00 - 10:50am M W F RH 312 Catalog Description ETME 422 PRINCIPLES OF HVAC I F 3 cr. LEC 3 PREREQUISITE: EMEC 320 or EGEN 324. -- Refrigeration and heating, ventilating and air-conditioning (HVAC) for comfort and industrial applications

Dyer, Bill

393

Residential HVAC Data, Assumptions and Methodology for End-Use Forecasting with EPRI-REEPS 2.1  

E-Print Network (OSTI)

LBL-34045 UC-1600 Residential HVAC Data, Assumptions and Methodology for End-Use Forecasting-uses include Heating, Ventilation and Air Conditioning (HVAC). Our analysis uses the modeling framework provided by the HVAC module in the Residential End-Use Energy Planning System (REEPS), which was developed

394

Predicting of fan speed for energy saving in HVAC system based on adaptive network based fuzzy inference system  

Science Conference Proceedings (OSTI)

In this paper, a HVAC (heating, ventilating and air-conditioning) system has two different zones was designed and fan motor speed to minimize energy consumption of the HVAC system was controlled by a conventional (proportional-integral-derivative) PID ... Keywords: ANFIS, Air flow control, Energy saving, Fan motor speed predicting, HVAC system, PID control, Temperature control

Servet Soyguder; Hasan Alli

2009-05-01T23:59:59.000Z

395

Preliminary study of the potential for performance improvements in solar desiccant cooling  

DOE Green Energy (OSTI)

The basic operation of the desiccant cooling system is reviewed, and a preliminary evaluation of the potential for improving desiccant cooling system performance to COPs of 1.0 to 1.2 is performed. A second-law thermodynamic system analysis was carried out, demonstrating that present desiccant systems only achieve 10% to 15% of theoretical maximum performance and that a large potential for improvement exists. Computer simulations have been used to study the effects of improving desiccant properties and increasing the effectiveness of some components of the system. Results have shown that modification of desiccant properties can only produce a limited (10%) increase in COP. Larger increases can be achieved by increasing the effectiveness of the sensible heat exchanger. However, this study indicates that the key to obtaining higher COPs is in the design of the dehumidifier. One design that shows promise is the parallel passage dehumidifier.

Schlepp, D.R.; Barlow, R.

1981-10-01T23:59:59.000Z

396

Thermal storage HVAC system retrofit provides economical air conditioning  

Science Conference Proceedings (OSTI)

This article describes an EMS-controlled HVAC system that meets the ventilation and cooling needs of an 18,000-seat indoor ice hockey arena. The Buffalo Memorial Auditorium (affectionately referred to as the Aud) was built in 1937 under the Works Project Administration of the federal government. Its original configuration included a 12,000-seat arena with an ice skating rink. By the late 1980s, the city was unsuccessfully attempting to attract events and tenants to the auditorium, which lacked air conditioning and other modern amenities. Thus, it was decided to renovate the facility to make it marketable. The first phase of the renovation included installing an air-conditioning system in the arena and repairing the existing building systems that were inoperable because of deferred maintenance. After considering the existing conditions (such as size of the space, intermittent usage, construction restrictions, operating budgets and the limited operations staff), the engineering team designed an innovative HVAC system. The system's features include: a carbon dioxide monitoring device that controls the intake of outside air; an ice storage system that provides chilled water and shifts electrical demand to off-peak hours; and a design that uses the building mass as a heat sink. A new energy management system (EMS) determines building cooling needs based on the type of event, ambient conditions and projected audience size. Then, it selects the most economical method to obtain the desired arena temperature.

Smith, S.F. (Wendel Engineers, P.C., Buffalo, NY (United States))

1993-03-01T23:59:59.000Z

397

Avoiding low frequency noise in packaged HVAC equipment  

Science Conference Proceedings (OSTI)

The purpose of this article is to help those involved in the design and commissioning of packaged HVAC systems to understand the root causes of low frequency noise problems and how to avoid many of them at the design stage. In the 1980's, two things happened to dramatically change the types of noise problems encountered in typical new construction. The first was the introduction of new energy regulations that favored variable air volume (VAV) distribution systems over constant volume air distribution systems. A by-product of VAV design is that mid- and high frequency sound pressure levels produced by current air terminal devices and diffusers in many applications are significantly lower than in the past. The second factor was a trend away from the use of built-up central station fan equipment in favor of packaged, floor-by-floor air handlers or rooftop units. As a result, today's HVAC system noise problems are not confined to just the roar and hiss of the past, but now include intense low frequency rumble and time modulation. Indeed, most current noise problems in modern buildings occur in the frequency range well below 250 Hz. A large fraction of these are a result of the dominant sound pressure levels in the 12 to 40 Hz region. These factors, combined with a substantial increase in the level of low frequency sound from the rest of the system, can produce a non-neutral, time modulated, rumbly sounding background noise that many people find objectionable.

Ebbing, C.E. (Carrier Corp., Syracuse, NY (United States). Commercial Unitary Division); Blazier, W.E.Jr. (Warren Blazier Associates, San Francisco, CA (United States))

1993-06-01T23:59:59.000Z

398

Dynamic performance characterization of bound, porous silica gel desiccant  

DOE Green Energy (OSTI)

Drying of air with silica gel is a well established procedure. However, for the specific use of silica gel in a novel desiccant air conditioning system, which continually cools the silica gel and utilizes solar energy for silica gel regeneration, conventional packed bed devices are not suitable. For this system to operate effectively the silica gel must not rise in its temperature or its capacity will be greatly diminished. Dynamic dehumidificatuion performance was investigted for a silica gel desiccant fabricated in bound, porous paper-like sheets. Sheets of various thickness (0.7 to 3 mm) were fabricated and tested under several dynamic flow conditions in a flat rectangular channel apparatus. During each experiment conditions of inlet moisture, air flowrate, and sheet temperature were maintained constant. Comparisons were also made with conventional silica gel pellets and with other forms of bound silica gel. The sheets show superior utilization of silica gel in short times (30 minutes or less). Tests were also made to examine the sheet structure in order to explore the effect of temperature on the porous structure, and to obtain pore size distributions.

Onischak, M.; Gidaspow, D.; Perkari, S.; Sasaki, T.

1979-10-01T23:59:59.000Z

399

Simulations and economic analyses of desiccant cooling systems  

DOE Green Energy (OSTI)

The progress to date in the development and analysis of computer simulations of solar-powered desiccant cooling using an axial-flow disc-type dehumidifier wheel, solar-powered space heating, and electrically driven, standard vapor-compression air-conditioning systems for residential use is documented. Computer simulations for both solar and conventional heating and cooling systems were performed for 12-month heating and cooling seasons. Annual thermal performance and the resulting life cycle costs for both types of systems were analyzed and compared. The heating/cooling season simulations were run for five U.S. cities representing a wide range of climatic conditions and insolation. With the informaion resulting from these simulations, the optimum air-conditioning system was chosen to maximize the conservation of fossil fuels and minimize operating costs. Because of the increasing use of residential air conditioning employing electrically driven vapor-compression coolers, the five locations were studied to determine if it would be beneficial (in terms of both economics and fossil fuel displacement) to displace fossil-fuel-powered vapor-compression coolers and natural gas space heaters with solar-powered heating and desiccant cooling systems.

Shelpuk, B. C.; Hooker, D. W.; Jorgensen, G. J.; Bingham, C. E.

1979-06-01T23:59:59.000Z

400

Field-Scale Assessment of Desiccation Implementation for Deep Vadose Zone Contaminants  

Science Conference Proceedings (OSTI)

Desiccation of the vadose zone has the potential to reduce the flux of contaminants to underlying groundwater by removing moisture and decreasing the aqueous-phase permeability of the desiccated zone. However, data to evaluate implementation of desiccation are needed to enable consideration of desiccation as a potential remedy. Implementation of desiccation was field tested by injecting dry nitrogen gas to a target treatment zone and monitoring the spatial and temporal progress of the drying process. Aqueous waste discharges to disposal cribs approximately 50 years ago distributed water and contaminants, including primarily technetium-99 and nitrate, within the 100-m deep vadose zone at the test site. A field test location was selected adjacent to one of the former disposal cribs. The test was conducted in a contaminated portion of the vadose zone dominated by fine sands with lenses of silt material. Desiccation reduced volumetric moisture content to as low as 0.01. The lateral and vertical distribution of drying from the injection well was influenced by the subsurface heterogeneity. However, over time, desiccation occurred in the initially wetter, lower permeability lenses.

Truex, Michael J.; Oostrom, Martinus; Strickland, Christopher E.; Chronister, Glen B.; Benecke, Mark W.; Johnson, Christian D.

2012-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "liquid desiccant hvac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Study of parameters affecting the performance of solar desiccant cooling systems  

DOE Green Energy (OSTI)

The performance of a solar desiccant cooling system depends on the performance of its components, particularly the desiccant dehumidifier and solar collectors. The desiccant dehumidifier performance is affected by the properties of the desiccant, particularly the shape of the isotherm and the regeneration temperature. The performance of a solar collector, as one would expect, depends on its operating temperature, which is very close to the desiccant regeneration temperature. The purpose of this study was to identify the desiccant isotherm shape (characterized by separation factor) that would result in the optimum performance - based on thermal coefficient of performance and cooling capacity - of a desiccant cooling cycle operating in ventilation mode. Different regeneration temperatures ranging from 65[degree]C to 160[degree]C were investigated to identify the corresponding optimum isotherm shape at each. Thermal COP dictates the required area of the solar collectors, and the cooling capacity is an indication of the size and cost of the cooling equipment. Staged and no-staged regeneration methods were studied.

Pesaran, A.A.; Hoo, E.A.

1993-01-01T23:59:59.000Z

402

Study of parameters affecting the performance of solar desiccant cooling systems  

DOE Green Energy (OSTI)

The performance of a solar desiccant cooling system depends on the performance of its components, particularly the desiccant dehumidifier and solar collectors. The desiccant dehumidifier performance is affected by the properties of the desiccant, particularly the shape of the isotherm and the regeneration temperature. The performance of a solar collector, as one would expect, depends on its operating temperature, which is very close to the desiccant regeneration temperature. The purpose of this study was to identify the desiccant isotherm shape (characterized by separation factor) that would result in the optimum performance - based on thermal coefficient of performance and cooling capacity - of a desiccant cooling cycle operating in ventilation mode. Different regeneration temperatures ranging from 65{degree}C to 160{degree}C were investigated to identify the corresponding optimum isotherm shape at each. Thermal COP dictates the required area of the solar collectors, and the cooling capacity is an indication of the size and cost of the cooling equipment. Staged and no-staged regeneration methods were studied.

Pesaran, A.A.; Hoo, E.A.

1993-01-01T23:59:59.000Z

403

Woodmont Enterprises LLC | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7AC Technologies, Inc. 7AC Technologies, Inc. National Renewable Energy Laboratory 498 likes 7AC Technologies, based in Woburn, Massachusetts, is developing Liquid Desiccant HVAC systems for Commercial and Industrial buildings using technology from the National Renewable Energy Laboratory. These Liquid Desiccant HVAC systems deliver a 50 to 75 percent reduction in energy usage over conventional HVAC units. The system consists of a membrane conditioner responsible for drying and cooling the air and a heat-driven regenerator. The liquid desiccant design allows for the utilization of solar or waste heat sources, paving the way for net-zero energy retrofits to existing buildings with costs comparable to conventional HVAC. Learn More Borla Performance Industries, Inc. Oak Ridge National Laboratory

404

Iowa Powder Atomization Technologies, Inc. | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7AC Technologies, Inc. 7AC Technologies, Inc. National Renewable Energy Laboratory 498 likes 7AC Technologies, based in Woburn, Massachusetts, is developing Liquid Desiccant HVAC systems for Commercial and Industrial buildings using technology from the National Renewable Energy Laboratory. These Liquid Desiccant HVAC systems deliver a 50 to 75 percent reduction in energy usage over conventional HVAC units. The system consists of a membrane conditioner responsible for drying and cooling the air and a heat-driven regenerator. The liquid desiccant design allows for the utilization of solar or waste heat sources, paving the way for net-zero energy retrofits to existing buildings with costs comparable to conventional HVAC. Learn More Borla Performance Industries, Inc. Oak Ridge National Laboratory

405

Integrated Dynamic Electron Solutions, Inc. | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7AC Technologies, Inc. 7AC Technologies, Inc. National Renewable Energy Laboratory 498 likes 7AC Technologies, based in Woburn, Massachusetts, is developing Liquid Desiccant HVAC systems for Commercial and Industrial buildings using technology from the National Renewable Energy Laboratory. These Liquid Desiccant HVAC systems deliver a 50 to 75 percent reduction in energy usage over conventional HVAC units. The system consists of a membrane conditioner responsible for drying and cooling the air and a heat-driven regenerator. The liquid desiccant design allows for the utilization of solar or waste heat sources, paving the way for net-zero energy retrofits to existing buildings with costs comparable to conventional HVAC. Learn More Borla Performance Industries, Inc. Oak Ridge National Laboratory

406

Element One, Inc. | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7AC Technologies, Inc. 7AC Technologies, Inc. National Renewable Energy Laboratory 498 likes 7AC Technologies, based in Woburn, Massachusetts, is developing Liquid Desiccant HVAC systems for Commercial and Industrial buildings using technology from the National Renewable Energy Laboratory. These Liquid Desiccant HVAC systems deliver a 50 to 75 percent reduction in energy usage over conventional HVAC units. The system consists of a membrane conditioner responsible for drying and cooling the air and a heat-driven regenerator. The liquid desiccant design allows for the utilization of solar or waste heat sources, paving the way for net-zero energy retrofits to existing buildings with costs comparable to conventional HVAC. Learn More Borla Performance Industries, Inc. Oak Ridge National Laboratory

407

SynchroPET LLC | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7AC Technologies, Inc. 7AC Technologies, Inc. National Renewable Energy Laboratory 498 likes 7AC Technologies, based in Woburn, Massachusetts, is developing Liquid Desiccant HVAC systems for Commercial and Industrial buildings using technology from the National Renewable Energy Laboratory. These Liquid Desiccant HVAC systems deliver a 50 to 75 percent reduction in energy usage over conventional HVAC units. The system consists of a membrane conditioner responsible for drying and cooling the air and a heat-driven regenerator. The liquid desiccant design allows for the utilization of solar or waste heat sources, paving the way for net-zero energy retrofits to existing buildings with costs comparable to conventional HVAC. Learn More Borla Performance Industries, Inc. Oak Ridge National Laboratory

408

Teknikem, A Division of RockinBoat LLC | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7AC Technologies, Inc. 7AC Technologies, Inc. National Renewable Energy Laboratory 498 likes 7AC Technologies, based in Woburn, Massachusetts, is developing Liquid Desiccant HVAC systems for Commercial and Industrial buildings using technology from the National Renewable Energy Laboratory. These Liquid Desiccant HVAC systems deliver a 50 to 75 percent reduction in energy usage over conventional HVAC units. The system consists of a membrane conditioner responsible for drying and cooling the air and a heat-driven regenerator. The liquid desiccant design allows for the utilization of solar or waste heat sources, paving the way for net-zero energy retrofits to existing buildings with costs comparable to conventional HVAC. Learn More Borla Performance Industries, Inc. Oak Ridge National Laboratory

409

Umpqua Energy, Inc. | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7AC Technologies, Inc. 7AC Technologies, Inc. National Renewable Energy Laboratory 498 likes 7AC Technologies, based in Woburn, Massachusetts, is developing Liquid Desiccant HVAC systems for Commercial and Industrial buildings using technology from the National Renewable Energy Laboratory. These Liquid Desiccant HVAC systems deliver a 50 to 75 percent reduction in energy usage over conventional HVAC units. The system consists of a membrane conditioner responsible for drying and cooling the air and a heat-driven regenerator. The liquid desiccant design allows for the utilization of solar or waste heat sources, paving the way for net-zero energy retrofits to existing buildings with costs comparable to conventional HVAC. Learn More Borla Performance Industries, Inc. Oak Ridge National Laboratory

410

US e-Chromic | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7AC Technologies, Inc. 7AC Technologies, Inc. National Renewable Energy Laboratory 498 likes 7AC Technologies, based in Woburn, Massachusetts, is developing Liquid Desiccant HVAC systems for Commercial and Industrial buildings using technology from the National Renewable Energy Laboratory. These Liquid Desiccant HVAC systems deliver a 50 to 75 percent reduction in energy usage over conventional HVAC units. The system consists of a membrane conditioner responsible for drying and cooling the air and a heat-driven regenerator. The liquid desiccant design allows for the utilization of solar or waste heat sources, paving the way for net-zero energy retrofits to existing buildings with costs comparable to conventional HVAC. Learn More Borla Performance Industries, Inc. Oak Ridge National Laboratory

411

SH Coatings LP | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7AC Technologies, Inc. 7AC Technologies, Inc. National Renewable Energy Laboratory 498 likes 7AC Technologies, based in Woburn, Massachusetts, is developing Liquid Desiccant HVAC systems for Commercial and Industrial buildings using technology from the National Renewable Energy Laboratory. These Liquid Desiccant HVAC systems deliver a 50 to 75 percent reduction in energy usage over conventional HVAC units. The system consists of a membrane conditioner responsible for drying and cooling the air and a heat-driven regenerator. The liquid desiccant design allows for the utilization of solar or waste heat sources, paving the way for net-zero energy retrofits to existing buildings with costs comparable to conventional HVAC. Learn More Borla Performance Industries, Inc. Oak Ridge National Laboratory

412

Vorbeck Materials Corp. | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7AC Technologies, Inc. 7AC Technologies, Inc. National Renewable Energy Laboratory 498 likes 7AC Technologies, based in Woburn, Massachusetts, is developing Liquid Desiccant HVAC systems for Commercial and Industrial buildings using technology from the National Renewable Energy Laboratory. These Liquid Desiccant HVAC systems deliver a 50 to 75 percent reduction in energy usage over conventional HVAC units. The system consists of a membrane conditioner responsible for drying and cooling the air and a heat-driven regenerator. The liquid desiccant design allows for the utilization of solar or waste heat sources, paving the way for net-zero energy retrofits to existing buildings with costs comparable to conventional HVAC. Learn More Borla Performance Industries, Inc. Oak Ridge National Laboratory

413

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

41 - 2250 of 31,917 results. 41 - 2250 of 31,917 results. Page 7AC Technologies, Inc. 7AC Technologies, based in Woburn, Massachusetts, is developing Liquid Desiccant HVAC systems for Commercial and Industrial buildings using technology from the National Renewable Energy Laboratory. These Liquid Desiccant HVAC systems deliver a 50 to 75 percent reduction in energy usage over conventional HVAC units. The system consists of a membrane conditioner responsible for drying and cooling the air and a heat-driven regenerator. The liquid desiccant design allows for the utilization of solar or waste heat sources, paving the way for net-zero energy retrofits to existing buildings with costs comparable to conventional HVAC. http://energy.gov/americas-next-top-energy-innovator/7ac-technologies-inc

414

TrakLok Corporation | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7AC Technologies, Inc. 7AC Technologies, Inc. National Renewable Energy Laboratory 498 likes 7AC Technologies, based in Woburn, Massachusetts, is developing Liquid Desiccant HVAC systems for Commercial and Industrial buildings using technology from the National Renewable Energy Laboratory. These Liquid Desiccant HVAC systems deliver a 50 to 75 percent reduction in energy usage over conventional HVAC units. The system consists of a membrane conditioner responsible for drying and cooling the air and a heat-driven regenerator. The liquid desiccant design allows for the utilization of solar or waste heat sources, paving the way for net-zero energy retrofits to existing buildings with costs comparable to conventional HVAC. Learn More Borla Performance Industries, Inc. Oak Ridge National Laboratory

415

California Lithium Battery, Inc. | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7AC Technologies, Inc. 7AC Technologies, Inc. National Renewable Energy Laboratory 498 likes 7AC Technologies, based in Woburn, Massachusetts, is developing Liquid Desiccant HVAC systems for Commercial and Industrial buildings using technology from the National Renewable Energy Laboratory. These Liquid Desiccant HVAC systems deliver a 50 to 75 percent reduction in energy usage over conventional HVAC units. The system consists of a membrane conditioner responsible for drying and cooling the air and a heat-driven regenerator. The liquid desiccant design allows for the utilization of solar or waste heat sources, paving the way for net-zero energy retrofits to existing buildings with costs comparable to conventional HVAC. Learn More Borla Performance Industries, Inc. Oak Ridge National Laboratory

416

Application of Various HVAC Simulation Programs and Visual Tools to Commissioning  

E-Print Network (OSTI)

Various existing HVAC system simulation programs and visualization tools are considered to be potentially powerful tools for commissioning. Although not originally developed as commissioning tools, these programs facilitate the confirmation/comparison of HVAC system function and performance and enable detailed analysis of parameters influencing HVAC system performance. This paper investigates the functionality and ease of use of several such programs in support of the commissioning process. The investigation and assessment of simulation programs includes: Micro HASP, Micro ACSS, FACES, LCEM, HVACSIM+, TRNSYS, DOE-2, EnergyPlus and DeST and their visual tools.

Zheng, M.; Pan, S.

2007-01-01T23:59:59.000Z

417

Building America Expert Meeting Report: Transitioning Traditional HVAC Contractors to Whole House Performance Contractors  

DOE Green Energy (OSTI)

This report outlines findings resulting from a U.S. Department of Energy Building America expert meeting to determine how HVAC companies can transition from a traditional contractor status to a service provider for whole house energy upgrade contracting. IBACOS has embarked upon a research effort under the Building America Program to understand business impacts and change management strategies for HVAC companies. HVAC companies can implement these strategies in order to quickly transition from a 'traditional' heating and cooling contractor to a service provider for whole house energy upgrade contracting. Due to HVAC service contracts, which allow repeat interaction with homeowners, HVAC companies are ideally positioned in the marketplace to resolve homeowner comfort issues through whole house energy upgrades. There are essentially two primary ways to define the routes of transition for an HVAC contractor taking on whole house performance contracting: (1) Sub-contracting out the shell repair/upgrade work; and (2) Integrating the shell repair/upgrade work into their existing business. IBACOS held an Expert Meeting on the topic of Transitioning Traditional HVAC Contractors to Whole House Performance Contractors on March 29, 2011 in San Francisco, CA. The major objectives of the meeting were to: Review and validate the general business models for traditional HVAC companies and whole house energy upgrade companies Review preliminary findings on the differences between the structure of traditional HVAC Companies and whole house energy upgrade companies Seek industry input on how to structure information so it is relevant and useful for traditional HVAC contractors who are transitioning to becoming whole house energy upgrade contractors Seven industry experts identified by IBACOS participated in the session along with one representative from the National Renewable Energy Laboratory (NREL). The objective of the meeting was to validate the general operational profile of an integrated whole house performance contracting company and identify the most significant challenges facing a traditional HVAC contractor looking to transition to a whole house performance contractor. To facilitate the discussion, IBACOS divided the business operations profile of a typical integrated whole house performance contracting company (one that performs both HVAC and shell repair/upgrade work) into seven Operational Areas with more detailed Business Functions and Work Activities falling under each high-level Operational Area. The expert panel was asked to review the operational profile or 'map' of the Business Functions. The specific Work Activities within the Business Functions identified as potential transition barriers were rated by the group relative to the value in IBACOS creating guidance ensuring a successful transition and the relative difficulty in executing.

Burdick, A.

2011-10-01T23:59:59.000Z

418

HVAC Right-Sizing Part 1: Calculating Loads  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Building America Building America Presented by: Mike Gestwick - National Renewable Energy Laboratory Arlan Burdick, Anthony Grisolia - IBACOS, a Building America Research Team HVAC Right-Sizing Part 1: Calculating Loads Thursday, April 28 11:00 a.m. - 12:00 p.m. Eastern Building Technologies Program Mike Gestwick michael.gestwick@nrel.gov Building America: Introduction April 28, 2011 Introduction to Building America * Reduce energy use in new and existing residential buildings * Promote building science and systems engineering / integration approach * "Do no harm": Ensure safety, health and durability are maintained or improved * Accelerate adoption of high performance technologies www.buildingamerica.gov 15 Industry Research Teams Habitat Cost Effective Energy Retrofit Program

419

Commercial Building HVAC Energy Usage in Semi-Tropical Climates  

E-Print Network (OSTI)

The design of heating and cooling equipment in semi-tropical climates presents some design considerations and limitations not so prevalent in temperate climates. In some cases, the heating season may be non-existent for all practical purposes. Another consideration is the high ventilation loads due to cooling the moist air prevalent in semi-tropical climates. This paper describes a computer program which assesses all the pertinent variables which comprise the annual heating and cooling energy requirements for commercial buildings. It is then suggested that this computer program would be valuable in determining the changes one could expect in annual energy usage by varying certain building design parameters. Secondly, a small office building actually constructed in Central Florida in which the author designed the Heating and Cooling HVAC system is described. Tradeoffs are presented showing the effects of changes in these building design parameters.

Worbs, H. E.

1987-01-01T23:59:59.000Z

420

Revised noise criteria for design and rating of HVAC systems  

Science Conference Proceedings (OSTI)

This paper reviews current methods of rating the noise produced by HVAC systems and explains why these ratings fail to be correlated with subjective opinion in many cases. An entirely new method of assigning noise ratings is proposed which is expected to provide a significantly better correlation between objective measurements and subjective response. The proposed new rating method makes use of a revised set of noise criterion curves (RC curves) which appeared for the first time in Chap. 35 of the 1980 Systems Volume of the ASHRAE Handbook. This paper also discusses the technical considerations leading to the development of the RC curves as a replacement for the NC curves which have been used in the past.

Warren E. Blazier Jr.

1984-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "liquid desiccant hvac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Co-simulation of innovative integrated HVAC systems in buildings  

SciTech Connect

Integrated performance simulation of buildings HVAC systems can help in reducing energy consumption and increasing occupant comfort. However, no single building performance simulation (BPS) tool offers sufficient capabilities and flexibilities to analyze integrated building systems and to enable rapid prototyping of innovative building and system technologies. One way to alleviate this problem is to use co-simulation, as an integrated approach to simulation. This article elaborates on issues important for co-simulation realization and discusses multiple possibilities to justify the particular approach implemented in the here described co-simulation prototype. The prototype is validated with the results obtained from the traditional simulation approach. It is further used in a proof-of-concept case study to demonstrate the applicability of the method and to highlight its benefits. Stability and accuracy of different coupling strategies are analyzed to give a guideline for the required coupling time step.

Trcka, Marija; Hensena, Jan L.M.; Wetter, Michael

2010-06-21T23:59:59.000Z

422

Occupancy sensors for HVAC gaining in hotel industry  

SciTech Connect

The hotel industry is overcoming its skepticism as occupancy sensors with built-in thermistors to control heating, ventilating, and air conditioning (HVAC) units demonstrate their ability to cut energy costs as much as 30%. Despite the successful demonstrations and acceptance by Holiday Inn, some hotel managers of other chains continue to resist. Occupancy sensors have either ultrasonic or infrared signals, but differ from lighting control devices by also having internal thermistors and remote door switches. This allows the rooms to reach comfort levels only when the guest is present since occupants are only minimally affected if temperatures are modified during unoccupied periods. The system works best for roadside-type motels rather than convention hotels, where occupants are in and out of their rooms.

Ladd, C.

1985-12-02T23:59:59.000Z

423

Optimizing the performance of desiccant beds for solar-regenerated cooling  

DOE Green Energy (OSTI)

Detailed computer simulations as well as a simplified psychrometric analysis are used to determine the increase in cooling system performance that can be realized through the use of nonhomogeneous or staged desiccant beds. A staged bed of four hypothetical desiccants is shown to give a 10% higher cooling capacity than a silica gel bed of the same thickness. Alternatively, the same cooling capacity is produced by a staged bed 37% thinner than the silica gel bed. These effects could be employed to reduce the parasitic power requirements of desiccant cooling systems.

Barlow, R.; Collier, K.

1981-03-01T23:59:59.000Z

424

Laboratory and Modeling Evaluations in Support of Field Testing for Desiccation at the Hanford Site  

SciTech Connect

The Deep Vadose Zone Treatability Test Plan for the Hanford Central Plateau includes testing of the desiccation technology as a potential technology to be used in conjunction with surface infiltration control to limit the flux of technetium and other contaminants in the vadose zone to the groundwater. Laboratory and modeling efforts were conducted to investigate technical uncertainties related to the desiccation process and its impact on contaminant transport. This information is intended to support planning, operation, and interpretation of a field test for desiccation in the Hanford Central Plateau.

Truex, Michael J.; Oostrom, Martinus; Freedman, Vicky L.; Strickland, Christopher E.; Wietsma, Thomas W.; Tartakovsky, Guzel D.; Ward, Anderson L.

2011-02-23T23:59:59.000Z

425

Performance comparison of absorption and desiccant solar cooling systems  

DOE Green Energy (OSTI)

Cooling systems are required to operate over a wide range of outdoor and load conditions; however, the performance of solar cooling components is often specified and compared at a typical design point such as ARI conditions. A method is presented to directly compare the performance of different desiccant and absorption cooling systems by using psychrometric analysis of air distribution cycles under a range of outdoor conditions that systems encounter over a year. Using analysis of cooling load distributions for a small commercial office building in Miami and Phoenix a seasonal COP is calculated for each system. The heat input can be provided by solar or by an auxiliary heat source, such as natural gas.

Warren, M.L.; Wahlig, M.

1986-01-01T23:59:59.000Z

426

Heat and mass transfer analysis of a desiccant dehumidifier matrix  

DOE Green Energy (OSTI)

This report documents the SERI Single-Blow Test Facility's design, fabrication, and testing for characterizing desiccant dehumidifiers for solar cooling applications. The first test article, a silica-gel parallel-plate dehumidifier with highly uniform passages, was designed and fabricated. Transient heat and mass transfer data and pressure drop data across the dehumidifier were obtained. Available heat and mass transfer models were extended to the parallel-place geometry, and the experimental data were compared with model predictions. Pressure drop measurements were also compared with model predictions of the fully developed laminar flow theory. The comparisons between the lumped-capacitance model and the experimental data were satisfactory. The pressure drop data compared satisfactorily with the theory (within 15%). A solid-side resistance model that is more detailed and does not assume symmetrical diffusion in particles was recommended for performance. This study has increased our understanding of the heat and mass transfer in silica gel parallel-plate dehumidifiers.

Pesaran, A.A.

1986-07-01T23:59:59.000Z

427

Fight Fall Allergies and Save Energy by Checking Your HVAC System |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Fight Fall Allergies and Save Energy by Checking Your HVAC System Fight Fall Allergies and Save Energy by Checking Your HVAC System Fight Fall Allergies and Save Energy by Checking Your HVAC System October 15, 2012 - 3:19pm Addthis Change your furnace filter to help keep allergies at bay and keep your furnace and air conditioner running efficiently. | Photo courtesy of ©iStockphoto.com/JaniceRichard. Change your furnace filter to help keep allergies at bay and keep your furnace and air conditioner running efficiently. | Photo courtesy of ©iStockphoto.com/JaniceRichard. Elizabeth Spencer Communicator, National Renewable Energy Laboratory What does this mean for me? Change your furnace filters every month or two to keep your HVAC equipment operating efficiently. I have unbelievably horrible fall allergies. I've never figured out what

428

What are the Best HVAC Solutions for Low-Load, High Performance Homes?"  

Energy.gov (U.S. Department of Energy (DOE))

This presentation was given at the Summer 2012 DOE Building America meeting on July 26, 2012, and addressed the question What are the best HVAC solutions for low-load, high performance homes?"

429

Post-Retrocommissioning HVAC Operations Monitoring Using Enterprise-Wide energy Management System  

E-Print Network (OSTI)

Since 2004, the County of Los Angeles have retrocommissioned over 4 million square feet and additional RCx work is underway. The scope of the HVAC retrocommissioning (RCs) involved systematic investigation of mechanical, electrical and controls components/systems to diagnose and resolve root causes of operational deficiencies. During the implementation phase, new energy efficiency measures were installed, sequence of operations were optimized and functionally tested. System-level benchmark models for HVAC systems were developed based on optimized runs of eQUEST energy models and parametrically integrated into the County owned web-based Enterprise Energy Management Information Systems (EEMIS) with Itron/Silicon Energy EEM Suite backbone for the purpose of monitoring the operations of the HVAC systems. The paper and presentation describes the HVAC RCx process to optimize operations, cost and savings associated with this project and key operational changes to sustain optimized operations without sacrificing tenant comfort.

Amarnani, N.; Roberts, B.; Choy, H.

2007-01-01T23:59:59.000Z

430

A model-based fault detection and diagnostic methodology for secondary HVAC systems.  

E-Print Network (OSTI)

??In the U.S., buildings consume 39 % of primary energy, of which, 13.5% is attributed to HVAC systems. Faults, arising from sensors, equipment, and control… (more)

Li, Shun

2009-01-01T23:59:59.000Z

431

Control Systems and Applications for HVAC/R, 1st edition  

Science Conference Proceedings (OSTI)

From the Publisher:Unique in combining into one book, the operational and selection characteristics of commonly used control devices with the thermal and response characteristics of HVAC processes. It presents step-by-step techniques for analyzing the ...

Thomas J. Horan

1996-10-01T23:59:59.000Z

432

Development of New HVAC Design Tools: Search for the Holy Grail...  

NLE Websites -- All DOE Office Websites (Extended Search)

Development of New HVAC Design Tools: Search for the Holy Grail of Ventilation Research Speaker(s): Jelena Srebric Date: January 29, 2004 - 12:00pm Location: Bldg. 90 Seminar Host...

433

ASHRAE sound and vibration technical committee position statement on the use of fiberglass in HVAC systems  

Science Conference Proceedings (OSTI)

Fiberglass duct liner continues to be the most cost?effective solutions to noise control in most HVAC air duct systems. There has been a recent increase in the number of institutional

Russell A. Cooper

1995-01-01T23:59:59.000Z

434

Application of computational intelligence in modeling and optimization of HVAC systems.  

E-Print Network (OSTI)

?? HVAC (Heating Ventilating and Air-Conditioning) system is multivariate, nonlinear, and shares time-varying characteristics. It poses challenges for both system modeling and performance optimization. Traditional… (more)

Li, Mingyang

2009-01-01T23:59:59.000Z

435

A model-based predictive supervisory controller for multi-evaporator HVAC systems  

Science Conference Proceedings (OSTI)

Multi-evaporator vapor compression cooling systems are representative of the complex, distributed nature of modern HVAC systems. Earlier research efforts focused on the development of a decentralized control architecture for individual evaporators that ...

Matthew S. Elliott; Bryan P. Rasmussen

2009-06-01T23:59:59.000Z

436

DOE Convening Report on Certification of Commercial HVAC and CRE Products  

Energy.gov (U.S. Department of Energy (DOE))

This document is the convening report on the feasibility of a negotiated rulemaking to revise the certification program for commercial HVAC and CRE products published on October 2, 2012.

437

Applying brain emotional learning algorithm for multivariable control of HVAC systems  

Science Conference Proceedings (OSTI)

In this paper, we apply a modified version of Brain Emotional Learning (BEL) controller for Heating, Ventilating and Air Conditioning (HVAC) control system whose multivariable, nonlinear and non-minimum phase nature makes the task difficult. The proposed ...

N. Sheikholeslami; D. Shahmirzadi; E. Semsar; C. Lucas; M. J. Yazdanpanah

2006-01-01T23:59:59.000Z

438

Overview of developing programs in solar desiccant cooling for residential buildings  

DOE Green Energy (OSTI)

An overview is provided of the ongoing work in desiccant cooling under the national solar heating and cooling research program. Open cycle adsorption and absorption systems are examined. The different dehumidifier bed configurations are the distinguishing features of these systems. The basic operating principles of each dehumidifier concept are explained along with some discussion of their comparative features. Performance predictions developed by SERI for a solar desiccant solar system employing an axial-flow desiccant wheel dehumidifier are presented. In terms of life-cycle cost and displaced fossil-fuel energy, the results indicate that it should be beneficial to use solar desiccant coolers in residential applications. Although no prototype testing of any of these concepts is currently underway, test results are expected and will be reported within one year.

Not Available

1979-01-01T23:59:59.000Z

439

Deep Vadose Zone Treatability Test for the Hanford Central Plateau: Soil Desiccation Pilot Test Results  

Science Conference Proceedings (OSTI)

This report describes results of a pilot test of soil desiccation conducted as part of the Deep Vadose Zone Treatability Test program. The report is written in CERCLA treatabilty test report format.

Truex, Michael J.; Oostrom, Martinus; Strickland, Christopher E.; Johnson, Timothy C.; Freedman, Vicky L.; Johnson, Christian D.; Greenwood, William J.; Ward, Anderson L.; Clayton, Ray E.; Lindberg, Michael J.; Peterson, John E.; Hubbard, Susan; Chronister, Glen B.; Benecke, Mark W.

2012-05-01T23:59:59.000Z

440

Experimental and Numerical Investigations of Soil Desiccation for Vadose Zone Remediation: Report for Fiscal Year 2007  

SciTech Connect

Apart from source excavation, the options available for the remediation of vadose zone metal and radionuclide contaminants beyond the practical excavation depth (0 to 15 m) are quite limited. Of the available technologies, very few are applicable to the deep vadose zone with the top-ranked candidate being soil desiccation. An expert panel review of the work on infiltration control and supplemental technologies identified a number of knowledge gaps that would need to be overcome before soil desiccation could be deployed. The report documents some of the research conducted in the last year to fill these knowledge gaps. This work included 1) performing intermediate-scale laboratory flow cell experiments to demonstrate the desiccation process, 2) implementing a scalable version of Subsurface Transport Over Multiple Phases–Water-Air-Energy (STOMP-WAE), and 3) performing numerical experiments to identify the factors controlling the performance of a desiccation system.

Ward, Andy L.; Oostrom, Mart; Bacon, Diana H.

2008-02-04T23:59:59.000Z

Note: This page contains sample records for the topic "liquid desiccant hvac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

A Hierarchical Rule-Based Fault Detection and Diagnostic Method for HVAC Systems  

E-Print Network (OSTI)

A rule-based, system-level fault detection and diagnostic (FDD) method for HVAC systems was developed. It functions as an interface between multiple, equipment-specific FDD tools and a human operator. The method resolves and prioritizes conflicting fault reports from equipment-specific FDD tools, performs FDD at the system level, and presents an integrated view of an HVAC system’s fault status to an operator. A simulation study to test and evaluate the method was conducted.

Jeffrey Schein; Steven T. Bushby

2005-01-01T23:59:59.000Z

442

DOE Convening Report on Certification of Commercial HVAC and CRE Products  

NLE Websites -- All DOE Office Websites (Extended Search)

Convening Report on Certification of Commercial HVAC and CRE Products, October 2, 2012 Convening Report on Certification of Commercial HVAC and CRE Products, October 2, 2012 1 U.S. DEPARTMENT OF ENERGY CONVENING REPORT ON THE FEASIBILITY OF A NEGOTIATED RULEMAKING TO REVISE THE CERTIFICATION PROGRAM FOR COMMERCIAL HEATING, VENTILATING AIR CONDITIONING AND COMMERCIAL REFRIGERATION EQUIPMENT October 2, 2012 Alan W. Strasser, Esq., MA Convener

443

An Evaluation of the HVAC Load Potential for Providing Load Balancing Service  

Science Conference Proceedings (OSTI)

This paper investigates the potential of providing aggregated intra-hour load balancing services using heating, ventilating, and air-conditioning (HVAC) systems. A direct-load control algorithm is presented. A temperature-priority-list method is used to dispatch the HVAC loads optimally to maintain consumer-desired indoor temperatures and load diversity. Realistic intra-hour load balancing signals were used to evaluate the operational characteristics of the HVAC load under different outdoor temperature profiles and different indoor temperature settings. The number of HVAC units needed is also investigated. Modeling results suggest that the number of HVACs needed to provide a {+-}1-MW load balancing service 24 hours a day varies significantly with baseline settings, high and low temperature settings, and the outdoor temperatures. The results demonstrate that the intra-hour load balancing service provided by HVAC loads meet the performance requirements and can become a major source of revenue for load-serving entities where the smart grid infrastructure enables direct load control over the HAVC loads.

Lu, Ning

2012-09-30T23:59:59.000Z

444

A desiccant/steam-injected gas-turbine industrial cogeneration system  

SciTech Connect

An integrated desiccant/steam-injected gas-turbine system was evaluated as an industrial cogenerator for the production of electricity and dry, heated air for product drying applications. The desiccant can be regenerated using the heated, compressed air leaving the compressor. The wet stream leaves the regenerator at a lower temperature than when it entered the desiccant regenerator, but with little loss of energy. The wet stream returns to the combustion chamber of the gas-turbine system after preheating by exchanging heat with the turbine exhaust strewn. Therefore, the desiccant is regenerated virtually energy-free. In the proposed system, the moisture-laden air exiting the desiccant is introduced into the combustion chamber of the gas-turbine power system. This paper discusses various possible design configurations, the impact of increased moisture content on the combustion process, the pressure drop across the desiccant regenerator, and the impact of these factors on the overall performance of the integrated system. A preliminary economic analysis including estimated potential energy savings when the system is used in several drying applications, and equipment and operating costs are also presented.

Jody, B.J.; Daniels, E.J.; Karvelas, D.E.; Teotia, A.P.S.

1993-12-31T23:59:59.000Z

445

A desiccant/steam-injected gas-turbine industrial cogeneration system  

SciTech Connect

An integrated desiccant/steam-injected gas-turbine system was evaluated as an industrial cogenerator for the production of electricity and dry, heated air for product drying applications. The desiccant can be regenerated using the heated, compressed air leaving the compressor. The wet stream leaves the regenerator at a lower temperature than when it entered the desiccant regenerator, but with little loss of energy. The wet stream returns to the combustion chamber of the gas-turbine system after preheating by exchanging heat with the turbine exhaust strewn. Therefore, the desiccant is regenerated virtually energy-free. In the proposed system, the moisture-laden air exiting the desiccant is introduced into the combustion chamber of the gas-turbine power system. This paper discusses various possible design configurations, the impact of increased moisture content on the combustion process, the pressure drop across the desiccant regenerator, and the impact of these factors on the overall performance of the integrated system. A preliminary economic analysis including estimated potential energy savings when the system is used in several drying applications, and equipment and operating costs are also presented.

Jody, B.J.; Daniels, E.J.; Karvelas, D.E.; Teotia, A.P.S.

1993-01-01T23:59:59.000Z

446

Method and composition for molding low-density desiccant syntactic-foam articles  

DOE Patents (OSTI)

These and other objects of the invention are achieved by a process for molding to size a desiccant syntactic foam article having a density of 0.2 to 0.9 g/cc and a moisture capacity of 1 to 12% by weight, comprising the steps of: charging a mold with a powdery mixture of an activated desiccant, microspheres and a thermosetting resin, the amount of the desiccant being sufficient to provide the required moisture capacity, and the amounts of the microspheres and resin being such that the microspheres/desiccant volume fraction exceeds the packing factor by an amount sufficient to substantially avoid shrinkage without causing excessively high molding pressures; covering the mold and heating the covered mold to a temperature and for an amount of time sufficient to melt the resin; and tightly closing the mold and heating the closed mold to a temperature and for an amount of time sufficient to cure the resin, and removing the resultant desiccant syntactic foam article from the mold. In a composition of matter aspect, the present invention provides desiccant syntactic foam articles, and a composition of matter for use in molding the same.

Not Available

1981-12-07T23:59:59.000Z

447

Research and development needs for desiccant cooling technology 1992--1997. (Supplement to the NREL report, Desiccant Cooling: State-of-the-Art Assessment)  

SciTech Connect

This report is a supplement to Desiccant Cooling: State-of-the-Art Assessment (NREL/TP-254-4147, DE93000013). In this supplement document we have described a detailed program assuming sufficient funding to implement the R&D activities needed. Desiccant dehumidification is a mature technology for industrial applications, and in recent years the technology has been used for air conditioning a number of institutional and commercial buildings. Our proposal is based on argumentative discussions at various national meetings with leaders of the technology. The goal is the penetration of the broad air conditioning market. This work is funded by the Buildings technology Office of the US Department of Energy.

Pesaran, A.A.

1992-12-01T23:59:59.000Z

448

State-of-the-art sports facility's HVAC  

SciTech Connect

This article describes the HVAC systems design to keep Cleveland's new Gateway sports and entertainment complex comfortable. This magnificent new facility embraces the 42,000-seat Jacobs Field, with its natural grass playing surface, and the 21,000-seat Arena at Gateway (the official name will be announced at its August 1 opening). The Arena is the new home of the Cleveland Cavaliers NBA basketball team and the Lumberjacks IHL ice hockey team. Other events that will be held here include arena football, circuses, ice shows, and concerts. It is anticipated that the Arena will be in use in excess of 200 days a year for these and other functions. The ballpark and the arena are separated by Gateway Plaza, a large illuminated public space that also will be the site of various entertainment events. An air conditioned pedestrian bridge, approximately 0.7 miles in length, connects the Arena with the Regional Transit Authority's downtown rapid transit station. Other enclosed walkways connect the Arena with two parking garages (3,158 vehicles total) and the larger garage with Jacobs Field.

Horton, M.K. (Gateway Sports Complex, Cleveland, OH (United States))

1994-08-01T23:59:59.000Z

449

A Quasi-Dynamic HVAC and Building Simulation Methodology  

E-Print Network (OSTI)

This thesis introduces a quasi-dynamic building simulation methodology which complements existing building simulators by allowing transient models of HVAC (heating, ventilating and air-conditioning) systems to be created in an analogous way to their design and simulated in a computationally efficient manner. The methodology represents a system as interconnected, object-oriented sub-models known as components. Fluids and their local properties are modeled using discrete, incompressible objects known as packets. System wide pressure and flow rates are modeled similar to electrical circuit models. Transferring packets between components emulates fluid flow, while the system wide fluid circuit formed by the components' interconnections determines system wide pressures and flow rates. A tool named PAQS, after the PAacketized Quasi-dynamic Simulation methodology, was built to demonstrate the described methodology. Validation tests of PAQS found that its steady state energy use predictions differed less than 3% from a comparable steady state model. PAQS was also able to correctly model the transient behavior of a dynamic linear analytical system.

Davis, Clinton Paul

2012-05-01T23:59:59.000Z

450

Compression effects on pressure loss in flexible HVAC ducts  

SciTech Connect

A study was conducted to evaluate the effect of compression on pressure drop in flexible, spiral wire helix core ducts used in residential and light commercial applications. Ducts of 6 inches, 8 inches and 10 inches (150, 200 and 250 mm) nominal diameters were tested under different compression configurations following ASHRAE Standard 120-1999--Methods of Testing to Determine Flow Resistance of HVAC Air Ducts and Fittings. The results showed that the available published references tend to underestimate the effects of compression. The study demonstrated that moderate compression in flexible ducts, typical of that often seen in field installations, could increase the pressure drop by a factor of four, while further compression could increase the pressure drop by factors close to ten. The results proved that the pressure drop correction factor for compressed ducts cannot be independent of the duct size, as suggested by ASHRAE Fundamentals, and therefore a new relationship was developed for better quantification of the pressure drop in flexible ducts. This study also suggests potential improvements to ASHRAE Standard 120-1999 and provides new data for duct design.

Abushakra, Bass; Walker, Iain S.; Sherman, Max H.

2002-07-01T23:59:59.000Z

451

Evaluation of flow capture techniques for measuring HVAC grilleairflows  

SciTech Connect

This paper discusses the accuracy of commercially available flow hoods for residential applications. Results of laboratory and field tests indicate these hoods can be inadequate to measure airflows in residential systems, and there can be large measurement discrepancies between different flow hoods. The errors are due to poor calibrations, sensitivity of the hoods to grille airflow non-uniformities, and flow changes from added flow resistance. It is possible to obtain reasonable results using some flow hoods if the field tests are carefully done, the grilles are appropriate, and grille location does not restrict flow hood placement. We also evaluated several simple flow capture techniques for measuring grille airflows that could be adopted by the HVAC industry and homeowners as simple diagnostics. These simple techniques can be as accurate as commercially available devices. Our test results also show that current calibration procedures for flow hoods do not account for field application problems. As a result, agencies such as ASHRAE or ASTM need to develop a new standard for flow hood calibration, along with a new measurement standard to address field use of flow capture techniques.

Walker, Iain S.; Wray, Craig P.

2002-11-01T23:59:59.000Z

452

Economic Comparison of HVAC and HVDCSolutions for Large Offshore Wind Farms underSpecial Consideration of Reliability.  

E-Print Network (OSTI)

?? An economic comparison of several HVAC-HVDC transmission systems from large offshore windfarms is presented. The power output from the offshore windfarm is modeled by… (more)

Lazaridis, Lazaros

2005-01-01T23:59:59.000Z

453

Demand Response-Enabled Model Predictive HVAC Load Control in Buildings using Real-Time Electricity Pricing.  

E-Print Network (OSTI)

??A practical cost and energy efficient model predictive control (MPC) strategy is proposed for HVAC load control under dynamic real-time electricity pricing. The MPC strategy… (more)

Avci, Mesut

2013-01-01T23:59:59.000Z

454

A plug and play framework for an HVAC air handling unit and temperature sensor auto recognition technique.  

E-Print Network (OSTI)

??A plug and play framework for an HVAC air handling unit control system is proposed in this study. This is the foundation and the first… (more)

Zhou, Xiaohui

2010-01-01T23:59:59.000Z

455

Tecniche di apprendimento automatico per la rilevazione di malfunzionamenti in sistemi HVAC: il caso di un refrigeratore di liquido centrifugo.  

E-Print Network (OSTI)

??Malfunzionamenti in sistemi di riscaldamento, ventilazione e aria condizionata (HVAC) possono essere rilevati attraverso sitemi di Fault Detection. Spesso le informazioni riguardanti guasti e anomalie… (more)

Corazzol, Chiara

2013-01-01T23:59:59.000Z

456

System dynamics based models for selecting HVAC systems for office buildings: a life cycle assessment from carbon emissions perspective.  

E-Print Network (OSTI)

??This study aims to explore the life cycle environmental impacts of typical heating ventilation and air condition (HVAC) systems including variable air volume (VAV) system,… (more)

Chen, S

2011-01-01T23:59:59.000Z

457

Framework combining static optimization, dynamic scheduling and decision analysis applicable to complex primary HVAC&R systems.  

E-Print Network (OSTI)

??The primary objective of this work is to propose a general and computationally efficient methodology for dynamic scheduling and optimal control of primary HVAC&R systems… (more)

Jiang, Wei

2006-01-01T23:59:59.000Z

458

Laboratory And Field Investigations To Address Erosion, Volume Change And Desiccation Cracking Of Compost Amended Expansive Subsoils.  

E-Print Network (OSTI)

??Puppala, Anand Desiccations cracks are formed during drying process of fine grained cohesive soils in summer and these cracks often appear on unpaved subgrades due… (more)

Intharasombat, Napat

2007-01-01T23:59:59.000Z

459

RELIABILITY ANALYSIS OF THE ELECTRICAL POWER DISTRIBUTION SYSTEM TO SELECTED PORTIONS OF THE NUCLEAR HVAC SYSTEM  

Science Conference Proceedings (OSTI)

A design requirement probability of 0.01 or less in a 4-hour period ensures that the nuclear heating, ventilation, and air-conditioning (HVAC) system in the primary confinement areas of the Dry Transfer Facilities (DTFs) and Fuel Handling Facility (FHF) is working during a Category 1 drop event involving commercial spent nuclear fuel (CSNF) assemblies (BSC 2004a , Section 5.1.1.48). This corresponds to an hourly HVAC failure rate of 2.5E-3 per hour or less, which is contributed to by two dominant causes: equipment failure and loss of electrical power. Meeting this minimum threshold ensures that a Category 1 initiating event followed by the failure of HVAC is a Category 2 event sequence. The two causes for the loss of electrical power include the loss of offsite power and the loss of onsite power distribution. Thus, in order to meet the threshold requirement aforementioned, the failure rate of mechanical equipment, loss of offsite power, and loss of onsite power distribution must be less than or equal to 2.5E-3 per hour for the nuclear HVAC system in the primary confinement areas of the DTFs and FHF. The loss of offsite power occurs at a frequency of 1.1E-5 per hour (BSC 2004a, Section 5.1.1.48). The purpose of this analysis is to determine the probability of occurrence of the unavailability of the nuclear HVAC system in the primary confinement areas of the DTFs and FHF due to loss of electrical power. In addition, this analysis provides insights on the contribution to the unavailability of the HVAC system due to equipment failure. The scope of this analysis is limited to finding the frequency of loss of electrical power to the nuclear HVAC system in the primary confinement areas of the DTFs and FHF.

N. Ramirez

2004-12-16T23:59:59.000Z

460

Application of Functional Link Neural Network to HVAC Thermal Dynamic System Identification  

E-Print Network (OSTI)

Abstract — Recent efforts to incorporate aspects of artificial intelligence into the design and operation of automatic control systems have focused attention on techniques such as fuzzy logic, artificial neural networks, and expert systems. The use of computers for direct digital control highlights the recent trend toward more effective and efficient heating, ventilating, and airconditioning (HVAC) control methodologies. Researchers in the HVAC field have stressed the importance of self learning in building control systems and have encouraged further studies in the integration of optimal control and other advanced techniques into the formulation of such systems. Artificial neural networks can also be used to emulate the plant dynamics, in order to estimate future plant outputs and obtain plant input/output sensitivity information for on-line neural control adaptation. This paper describes a functional link neural network approach to performing the HVAC thermal dynamic system identification. Methodologies to reduce inputs of the functional link network to reduce the complexity and speed up the training speed will be presented. Analysis and comparison between the functional link network approach and the conventional network approach for the HVAC thermal modeling will also be presented. Index Terms—Functional link, HVAC, intelligent control, neural network, system identification.

Jason Teeter; Mo-yuen Chow; Senior Member

1998-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "liquid desiccant hvac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Performance Assessment of a Desiccant Cooling System in a CHP Application with an IC Engine  

DOE Green Energy (OSTI)

Performance of a desiccant cooling system was evaluated in the context of combined heat and power (CHP). The baseline system incorporated a desiccant dehumidifier, a heat exchanger, an indirect evaporative cooler, and a direct evaporative cooler. The desiccant unit was regenerated through heat recovery from a gas-fired reciprocating internal combustion engine. The system offered sufficient sensible and latent cooling capacities for a wide range of climatic conditions, while allowing influx of outside air in excess of what is typically required for commercial buildings. Energy and water efficiencies of the desiccant cooling system were also evaluated and compared with those of a conventional system. The results of parametric assessments revealed the importance of using a heat exchanger for concurrent desiccant post cooling and regeneration air preheating. These functions resulted in enhancement of both the cooling performance and the thermal efficiency, which are essential for fuel utilization improvement. Two approaches for mixing of the return air and outside air were examined, and their impact on the system cooling performance and thermal efficiency was demonstrated. The scope of the parametric analyses also encompassed the impact of improving the indirect evaporative cooling effectiveness on the overall cooling system performance.

Jalalzadeh-Azar, A. A.; Slayzak, S.; Judkoff, R.; Schaffhauser, T.; DeBlasio, R.

2005-04-01T23:59:59.000Z

462

SOIL DESICCATION TECHNIQUES STRATEGIES FOR IMMOBILIZATION OF DEEP VADOSE CONTAMINANTS AT THE HANFORD CENTRAL PLATEAU  

SciTech Connect

Deep vadose zone contamination poses some of the most difficult remediation challenges for the protection of groundwater at the Hanford Site where processes and technologies are being developed and tested for use in the on-going effort to remediate mobile contamination in the deep vadose zone, the area deep beneath the surface. Historically, contaminants were discharged to the soil along with significant amounts of water, which continues to drive contaminants deeper in the vadose zone toward groundwater. Soil desiccation is a potential in situ remedial technology well suited for the arid conditions and the thick vadose zone at the Hanford Site. Desiccation techniques could reduce the advance of contaminants by removing the pore water to slow the rate of contaminants movement toward groundwater. Desiccation technologies have the potential to halt or slow the advance of contaminants in unsaturated systems, as well as aid in reduction of contaminants from these same areas. Besides reducing the water flux, desiccation also establishes capillary breaks that would require extensive rewetting to resume pore water transport. More importantly, these techniques have widespread application, whether the need is to isolate radio nuclides or address chemical contaminant issues. Three different desiccation techniques are currently being studied at Hanford.

BENECKE MW; CHRONISTER GB; TRUEX MJ

2012-01-30T23:59:59.000Z

463

Metro Environmental: The impact of training HVAC technicians using the SightPros-VirTechs system for remote, wireless, Internet video assistance.  

E-Print Network (OSTI)

??This qualitative study explored the overall impact of training HVAC technicians using the SightPros-VirTechs system for remote, wireless, internet video assistance at a small HVAC… (more)

Daily, Ellen Wilmoth Matthews

2008-01-01T23:59:59.000Z

464

Critical Question #4: What are the Best Off-the-Shelf HVAC Solutions for  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Critical Question #4: What are the Best Off-the-Shelf HVAC Critical Question #4: What are the Best Off-the-Shelf HVAC Solutions for Low-Load, High-Performance Homes and Apartments? Critical Question #4: What are the Best Off-the-Shelf HVAC Solutions for Low-Load, High-Performance Homes and Apartments? What is currently in the market? What are the limitations of these systems? What are the desired specifications for these systems? What are the realistic space conditioning loads of these high-performance homes and apartments? cq4_forced_air_systems_walker.pdf cq4_simplified_space_cond_prahl.pdf cq4_ground_heat_exchanger_im.pdf More Documents & Publications Track C - Market-Driven Research Solutions Track B - Critical Guidance for Peak Performance Homes Energy Storage & Power Electronics 2008 Peer Review - Power Electronics

465

HVAC vs. Space Heaters: Which is More Efficient? | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? January 10, 2011 - 4:27pm Addthis Andrea Spikes Communicator at DOE's National Renewable Energy Laboratory I live in Colorado, and when it's cold it is very, very cold. Since I hate paying high heating bills, I typically have my thermostat set to a chilly 62°F. My husband and I have gotten used to this, and really like being able to use a warm comforter while the air stays cooler. There are some nights, however, that even this setting seems too high and the heater is running a lot more than I'd like it to. When it's below 0° overnight, or even sometimes during the day, we occasionally break out our oil-filled space heater when we're only using one room. That has me

466

HVAC vs. Space Heaters: Which is More Efficient? | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? January 10, 2011 - 4:27pm Addthis Andrea Spikes Communicator at DOE's National Renewable Energy Laboratory I live in Colorado, and when it's cold it is very, very cold. Since I hate paying high heating bills, I typically have my thermostat set to a chilly 62°F. My husband and I have gotten used to this, and really like being able to use a warm comforter while the air stays cooler. There are some nights, however, that even this setting seems too high and the heater is running a lot more than I'd like it to. When it's below 0° overnight, or even sometimes during the day, we occasionally break out our oil-filled space heater when we're only using one room. That has me

467

Realt-Time Building Occupancy Sensing for Supporting Demand Driven HVAC Operations  

E-Print Network (OSTI)

Accurate knowledge of localised and real-time occupancy numbers can have compelling control applications for Heating, Ventilation and Air-conditioning (HVAC) systems. However, a precise and reliable measurement of occupancy still remains difficult. Existing technologies are plagued with a number of issues ranging from unreliable data, maintaining privacy and sensor drift. More effective control of HVAC systems may be possible using a smart sensing network for occupancy detection. A low-cost and non-intrusive sensor network is deployed in an open-plan office, combining information such as sound level and motion, to estimate occupancy numbers, while an infrared camera is implemented to establish ground truth occupancy levels. Symmetrical uncertainty analysis is used for feature selection, and selected multi-sensory features are fused using a neuralnetwork model, with occupancy estimation accuracy reaching up to 84.59%. The proposed system offers promising opportunities for reliable occupancy sensing, capable of supporting demand driven HVAC operations.

Ekwevugbe, T.; Brown, N.; Pakka, V.

2013-01-01T23:59:59.000Z

468

On the capacity limits of hvac duct channel for high-speed internet access  

E-Print Network (OSTI)

Abstract—In this paper, we report theoretical and experimental channel-capacity estimates of heating, ventilation, and air conditioning (HVAC) ducts based on multicarrier transmission that uses-ary quadrature amplitude modulation and measured channel responses at the 2.4-GHz industrial, scientific, and medical band. It is shown theoretically that data rates in excess of 1 Gb/s are possible over distances up to 500 m in straight ducts in which reflections have been suppressed. Our experimental results also show that even in the case of more complex HVAC duct networks (i.e., HVAC duct networks that include bends, tees, etc.) data rates over 2 Gb/s are possible. Our estimations in this case are valid for distances of up to 22 m, which was the maximum distance of our experimental setup. These experimental results, measured with a large-scale testbed set

Ariton E. Xhafa; Ozan K. Tonguz; Ahmet G. Cepni; Student Member; Daniel D. Stancil; Pavel V. Nikitin; Dagfin Brodtkorb

2005-01-01T23:59:59.000Z

469

Energy Renovations: Volume 14: HVAC - A Guide for Contractors to Share with Homeowners  

SciTech Connect

This report was prepared by PNNL for DOE's Building America program and is intended as a guide that energy performance contractors can share with homeowners to describe various energy-efficient options for heating, cooling, and ventilating existing homes. The report provides descriptions of many common and not-so-common HVAC systems, including their advantages and disadvantages, efficiency ranges and characteristics of high-performance models, typical costs, and climate considerations. The report also provides decision trees and tables of useful information for homeowners who are making decisions about adding, replacing, or upgrading existing HVAC equipment in their homes. Information regarding home energy performance assessments (audits) and combustion safety issues when replacing HVAC equipment are also provided.

Gilbride, Theresa L.; Baechler, Michael C.; Hefty, Marye G.; Hand, James R.; Love, Pat M.

2011-08-29T23:59:59.000Z

470

Improving Gas-Fired Heat Pump Capacity and Performance by Adding a Desiccant Dehumidification Subsystem  

E-Print Network (OSTI)

This paper examines the merits of coupling a desiccant dehumidification subsystem to a gas-engine- driven vapor compression air conditioner. A system is identified that uses a rotary, silica gel, parallel-plate dehumidifier. Dehumidifier data and analysis are based on recent tests. The dehumidification subsystem processes the fresh air portion and handles the latent portion of the load. Adding the desiccant subsystem increases the gas-based coefficient of performance 40% and increases the cooling capacity 50%. Increased initial manufacturing costs are estimated at around $500/ton ($142/kW) for volume production. This cost Level is expected to reduce the total initial cost per ton compared to a system without the desiccant subsystem.

Parsons, B. K.; Pesaran, A. A.; Bharathan, D.; Shelpuk, B. C.

1990-01-01T23:59:59.000Z

471

Performance predictions of silica-gel desiccant dehumidifiers. Technical report No. 3  

SciTech Connect

The analysis of a cross-cooled desiccant dehumidifier using silica gel in the form of sheets is described. This unit is the principal component of solar powered desiccant air conditioning system. The mathematical model has first been formulated describing the dynamics of the dehumidifier. The model leads to a system of nonlinear coupled heat and mass transfer equations for the sorption processes and linear heat transfer equations for the purging processes. The model accounts for the gas film resistance and for the moisture diffusion in the desiccant. The governing equations are solved by a finite difference scheme to obtain periodic steady state solutions. The accuracy of the theoretical predictions is ascertained by comparing them with the experimental results. The performance of the dehumidifier, for a chosen set of initial conditions and dehumidifier parameters, has also been given.

Mathiprakasam, B.; Lavan, Z.

1980-01-01T23:59:59.000Z

472

Contract No. EG-77-C-01-4042OPTIMIZING 'l%E PERFORWANCE OF DESICCANT BEDS FOB SOLAR RJXENEXATED COOLING  

E-Print Network (OSTI)

Lavan and Lunde have recognized this problem and have advocated nonadiabatic drying of the air; Lavan (4) investigating a crosscooled desiccant bed, and Lunde (5> propos-Ing a series of desiccant beds and heat exchangers. The purpose in both concepts is to keep the temperature of the silica gel low during adsorption so that the moisture capacity remains high. 1.

Kirk Collier; Robert Barlow; Kirk Collier

1981-01-01T23:59:59.000Z

473

An Application of State-Of-The-Art HVAC and Building Systems  

E-Print Network (OSTI)

This case study describes the successful application of state-of-the-art HVAC and building systems at a large commercial office and industrial facility. The facility's exterior envelope systems, HVAC systems, lighting systems, energy conservation systems, exhaust/heat recovery/make-up air systems, water cooling systems, compressed air systems, electrical distribution systems, water heating systems, and other systems and measures taken are each discussed in detail. The important role that energy engineering played in the overall planning, design, and management of the project is given particular emphasis. Also, the engineering strategies used to integrate energy efficiency, performance optimization, current technology, and cost effectiveness are underscored throughout.

Fiorino, D. P.

1988-09-01T23:59:59.000Z

474

High-Speed Internet Access via HVAC Ducts: A New Approach Daniel D. Stancil, Ozan K. Tonguz, Ariton Xhafa, Ahmet Cepni, and Pavel Nikitin  

E-Print Network (OSTI)

High-Speed Internet Access via HVAC Ducts: A New Approach Daniel D. Stancil, Ozan K. Tonguz, Ariton conditioning (HVAC) ducts for indoor wireless transmission systems and networks. Mea- surements and system to 100 Mbps should be possible, when HVAC system is used in con- junction with OFDM technology. Keywords

Stancil, Daniel D.

475

A Simple Path Loss Prediction Model for HVAC Systems O. K. Tonguz, D. D. Stancil, A. E. Xhafa, A. G. Cepni, P. V. Nikitin  

E-Print Network (OSTI)

1 A Simple Path Loss Prediction Model for HVAC Systems O. K. Tonguz, D. D. Stancil, A. E. Xhafa, A, and air conditioning (HVAC) cylindrical ducts in 2.4-2.5 GHz frequency band. The model we propose predicts the average power loss between a transmitter-receiver pair in an HVAC duct network. This prediction model

Stancil, Daniel D.

476

IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, VOL. 51, NO. 5, MAY 2003 945 Propagation Model for the HVAC Duct as a  

E-Print Network (OSTI)

for the HVAC Duct as a Communication Channel Pavel V. Nikitin, Member, IEEE, Daniel D. Stancil, Senior Member (HVAC) ducts in buildings are typically hollow metal pipes which can be used as waveguides to carry such a communication system. This paper presents a propagation model for a straight HVAC duct terminated at both ends

Stancil, Daniel D.

477

Review of the aquifer seasonal thermal energy storage building HVAC system at the Melville, New York, Mid-Island Mail Facility  

DOE Green Energy (OSTI)

The successful widespread commercialization of aquifer thermal energy storage (ATES) in the United States will depend on the effectiveness with which the experiences gained from early full-scale systems are used as guides in the design, installation and operation of future projects. One such early system from which both anecdotal and quantitative information is available is the Mid-Island Postal Facility in Melville, New York. At this facility, built in the mid-1980s, an ATES system has been integrated with the building's central heating and cooling plant. Cold'' wells are charged with water that is cooled during the winter by heat pump and closed circuit cooler operation. Water from these cold wells is then used to meet the facility's cooling load during the summer, before being pumped back into the ground at Warm'' wells. Dehumidification during summer operation is accomplished by a liquid desiccant system that uses propane boilers to provide a heat source for desiccant regeneration. This system will also add water to the air during periods of low humidity. This paper provides an overview of the project, and describes the analysis being performed to assess energy and economic merits of this innovative system.

Marseille, T.J.; Wilke, D.A.

1992-08-01T23:59:59.000Z

478

Review of the aquifer seasonal thermal energy storage building HVAC system at the Melville, New York, Mid-Island Mail Facility  

DOE Green Energy (OSTI)

The successful widespread commercialization of aquifer thermal energy storage (ATES) in the United States will depend on the effectiveness with which the experiences gained from early full-scale systems are used as guides in the design, installation and operation of future projects. One such early system from which both anecdotal and quantitative information is available is the Mid-Island Postal Facility in Melville, New York. At this facility, built in the mid-1980s, an ATES system has been integrated with the building`s central heating and cooling plant. ``Cold`` wells are charged with water that is cooled during the winter by heat pump and closed circuit cooler operation. Water from these cold wells is then used to meet the facility`s cooling load during the summer, before being pumped back into the ground at ``Warm`` wells. Dehumidification during summer operation is accomplished by a liquid desiccant system that uses propane boilers to provide a heat source for desiccant regeneration. This system will also add water to the air during periods of low humidity. This paper provides an overview of the project, and describes the analysis being performed to assess energy and economic merits of this innovative system.

Marseille, T.J.; Wilke, D.A.

1992-08-01T23:59:59.000Z

479

Desiccant solar air conditioning in tropical climates: II-field testing in Guadeloupe  

Science Conference Proceedings (OSTI)

This paper presents the results of the experimental investigation of a solar desiccant air conditioning device exposed to the sun in Guadeloupe to test that adaptability of a silicagel compact bed, the most simple technology, in a tropical climate. It has been shown that it is possible to make use of solar flat plate collectors with a balancing water tank, to produce heat for the regeneration of a solid desiccant as silicagel, with solar energy. Second, the compact bed system proposed gives the foreseen cooling power, but considerable losses appear, particularly in the sorption process, which is not close enough to the reversible adiabatic one.

Dupont, M.; Celestine, B.; Beghin, B. (Solar Energy Lab., Pointe-a-Pitre (Guadeloupe))

1994-06-01T23:59:59.000Z

480

Modeling of solid-side mass transfer in desiccant particle beds  

DOE Green Energy (OSTI)

A model is proposed for heat and mass transfer in a packed bed of desiccant particles and accounts for both Knudsen and surface diffusion within the particles. Using the model, predictions are made for the response of thin beds of silica gel particles to a step change in air inlet conditions compared to mental results. The predictions are found to be satisfactory and, in general, superior to those of pseudogas-side controlled models commonly used for the design of desiccant dehumidifiers for solar air conditioning application.

Pesaran, A.A.; Mills, A.F.

1984-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "liquid desiccant hvac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Research and development needs for desiccant cooling technology 1992--1997  

SciTech Connect

This report is a supplement to Desiccant Cooling: State-of-the-Art Assessment (NREL/TP-254-4147, DE93000013). In this supplement document we have described a detailed program assuming sufficient funding to implement the R D activities needed. Desiccant dehumidification is a mature technology for industrial applications, and in recent years the technology has been used for air conditioning a number of institutional and commercial buildings. Our proposal is based on argumentative discussions at various national meetings with leaders of the technology. The goal is the penetration of the broad air conditioning market. This work is funded by the Buildings technology Office of the US Department of Energy.

Pesaran, A.A.

1992-12-01T23:59:59.000Z

482

Improving fuzzy logic controllers obtained by experts: a case study in HVAC systems  

Science Conference Proceedings (OSTI)

One important Artificial Intelligence tool for automatic control is the use of fuzzy logic controllers, which are fuzzy rule-based systems comprising expert knowledge in form of linguistic rules. These rules are usually constructed by an expert in the ... Keywords: Fuzzy logic controllers, Genetic tuning, HVAC systems, Linguistic 2-tuples representation, Linguistic 3-tuples representation, Rule selection

Rafael Alcalá; Jesús Alcalá-Fdez; María José Gacto; Francisco Herrera

2009-08-01T23:59:59.000Z

483

Automatic two way synchronization between server and multiple clients for HVAC system  

Science Conference Proceedings (OSTI)

The authors study different two way synchronization methods between a server and distributed clients. Client-server architectures are used to control multiple instances from center. Hard-coded embedded controllers are replaced by embedded controllers ... Keywords: HVAC, data synchronization, embedded systems, multi-agent systems, online file storage, thick client

Anton Tyukov; Adriaan Brebels; Maxim Shcherbakov

2011-12-01T23:59:59.000Z

484

Computational Study on Thermal Properties of HVAC System with Building Structure Thermal Storage  

E-Print Network (OSTI)

Building structure thermal storage (BSTS) HVAC systems can store heat during nighttime thermal storage operation (nighttime operation hours) by using off-peak electricity and release it in the daytime air-conditioning operation (daytime operation hours) by utilizing a large amount of the thermal capacity of building structures such as beams, columns and floors composed of concrete. These BSTS systems have recently been considered as one method for leveling hourly electricity demands for HVAC on a day-to-day basis. Through a simulation using a model developed with experimental data, this paper describes how various factors for the design and operation of a BSTS quantitatively affect the charge/discharge performances of a HVAC system. As a result, the following was revealed: the thermal performance of the system is strongly influenced by the daily heat storage operation hours, supply air volume and supply air temperature during the nighttime operation hours, stored heat caused the total daytime cooling extraction to decrease by 11% to 58% and the daily total cooling extraction through nighttime to daytime to increase by 4% to 17% compared with the values of non- thermal storage HVAC system.

Sato, Y.; Sagara, N.; Ryu, Y.; Maehara, K.; Nagai, T.

2007-01-01T23:59:59.000Z

485

A Particle Swarm Optimization Approach for Optimal Design of PID Controller for Temperature Control in HVAC  

Science Conference Proceedings (OSTI)

Particle swarm optimization (PSO) is a novel evolutionary algorithm which has a better convergence rate and computation precision compared with other evolutionary algorithms. From the perspective of optimization, the self-tuning of PID controller parameters ... Keywords: PSO, PID, HVAC, Optimization, Particle Swarm Optimization

Zhang Jun; Zhang Kanyu

2011-01-01T23:59:59.000Z

486

OBSERVE: Occupancy-Based System for Efficient Reduction of HVAC Energy  

E-Print Network (OSTI)

control conditioning strategies. Using strategies based on sensor network occupancy model predictions, weOBSERVE: Occupancy-Based System for Efficient Reduction of HVAC Energy Varick L. Erickson, Miguel Á Descriptors I.6.5 [Simulation and Modeling]: Model Development; J.7 [Computers In Other Systems]: Command

Cerpa, Alberto E.

487

Energy Savings with Energy-Efficient HVAC Systems in Commercial Buildings of Hong Kong  

E-Print Network (OSTI)

Hong Kong has seen a dramatic increase in energy consumption in recent years, particularly electricity use in commercial buildings. The growth of electricity demand in future years is crucial both economically and environmentally. As over half of the electricity in Hong Kong is consumed by commercial buildings, and heating, ventilation and air-conditioning (HVAC) is the largest end-user in such buildings, improving the efficiency of HVAC systems in commercial buildings, is the key measure to take in Hong Kong for sustainable development. In this study, the major factors influencing the electricity use of HVAC systems are studied with the building energy simulation program EnergyPlus, which include chiller efficiency, space cooling temperature, variable vs. constant air flow, fan efficiency, lighting intensity and building envelope. From the analysis of the simulation results, it can be found that substantial energy-saving potential exists through improving the efficiency of HVAC systems in commercial buildings, and a combination of desirable system parameters for energy efficiency of commercial building is proposed.

Yang, J.; Chan, K.; Wu, X.

2006-01-01T23:59:59.000Z

488

IFC HVAC interface to EnergyPlus - A case of expanded interoperability for energy simulation  

SciTech Connect

Tedious manual input of data that define a building, its systems and its expected pattern of use and operating schedules for building energy performance simulation has in the past diverted time and resources from productive simulation runs. In addition to its previously released IFCtoIDF utility that semiautomates the import of building geometry, the new IFC HVAC interface to EnergyPlus (released at the end of 2003) makes it possible to import and export most of the data that define HVAC equipment and systems in a building directly from and to other IFC compatible software tools. This reduces the manual input of other data needed for successful simulation with EnergyPlus to a minimum. The main purpose of this new interface is to enable import of HVAC equipment and systems definitions, generated by other IFC compatible software tools (such as HVAC systems design tools) and data bases, into EnergyPlus, and to write such definitions contained in EnergyPlus input files to the original IFC files from which building geometry was extracted for the particular EnergyPlus input. In addition, this interface sets an example for developers of other software tools how to import and/or export data other than building geometry from and/or into EnergyPlus. This paper describes the necessary simplifications and shortcuts incorporated in this interface, its operating environment, interface architecture, and the basic conditions and methodology for its use with EnergyPlus.

Bazjanac, Vladimir; Maile, Tobias

2004-03-29T23:59:59.000Z

489

Identification of chiller model in HVAC system using fuzzy inference rules with Zadeh's implication operator  

Science Conference Proceedings (OSTI)

In the heating, ventilating, and air-conditioning (HVAC) system, chiller is the central part and one of the primary energy consumers. For the purpose of saving energy, the identification of the chiller model is of great significance. In this paper, based ... Keywords: chiller, fuzzy inference system, implication operator, improved genetic algorithm

Yukui Zhang; Shiji Song; Cheng Wu; Kang Li

2010-09-01T23:59:59.000Z

490

Theoretical and experimental analysis of desiccant wheel performance for low humidity drying system  

Science Conference Proceedings (OSTI)

The drying process is influenced by three main factors temperature, flow rate and humidity, resulting in the drying process of hot air required in accordance with the character of materials with low humidity, so it can speed up the drying process. Malaysia ... Keywords: desiccant wheel, temperature and humidity, water evaporation

Tri Suyono; Sohif Mat; Muhammad Yahya; Muhd. Hafiz Ruslan; Azami Zaharim; Kamaruzzaman Sopian

2011-10-01T23:59:59.000Z

491

Cryptic species within the cosmopolitan desiccation-tolerant moss Grimmia laevigata  

E-Print Network (OSTI)

Cryptic species within the cosmopolitan desiccation-tolerant moss Grimmia laevigata Catherine C cosmopolitan range. This presents an evolutionary puz- zle, the solution to which lies in understanding phylogeography The broad and, in some cases, cosmopolitan distribution of many moss species suggests

Thompson, John N.

492

Analysis and comparison of active solar desiccant and absorption cooling systems. Part 1; Model description  

DOE Green Energy (OSTI)

A comparative analysis has been performed to compare the cooling and dehumidification performance of future ventilation-mode desiccant systems, proposed advanced absorption systems, and conventional vapor compression systems. A common framework has been developed for direct comparison of these different cooling technologies; this method is described in this paper.

Warren, M.L. (ASI Controls, San Ramon, CA (US)); Wahlig, M. (Lawrence Berkeley Lab., CA (USA). Applied Science Div.)

1991-02-01T23:59:59.000Z

493

Sensor and numerical simulator evaluation for porous medium desiccation and rewetting at the intermediate laboratory scale  

Science Conference Proceedings (OSTI)

Soil desiccation, in conjunction with surface infiltration control, is considered at the Hanford Site as a potential technology to limit the flux of technetium and other contaminants in the vadose zone to the groundwater. An intermediate-scale experiment was conducted to test the response of a series of instruments to desiccation and subsequent rewetting of porous media. The instruments include thermistors, thermocouple psychrometers, dual-probe heat pulse sensors, heat dissipation units, and humidity probes. The experiment was simulated with the multifluid flow simulator STOMP, using independently obtained hydraulic and thermal porous medium properties. All instrument types used for this experiment were able to indicate when the desiccation front passed a certain location. In most cases the changes were sharp, indicating rapid changes in moisture content, water potential, or humidity. However, a response to the changing conditions was recorded only when the drying front was very close to a sensor. Of the tested instruments, only the heat dissipation unit and humidity probes were able to detect rewetting. The numerical simulation results reasonably match the experimental data, indicating that the simulator captures the pertinent gas flow and transport processes related to desiccation and rewetting and may be useful in the design and analysis of field tests.

Oostrom, Martinus; Wietsma, Thomas W.; Strickland, Christopher E.; Freedman, Vicky L.; Truex, Michael J.

2012-02-01T23:59:59.000Z

494

HVAC Equipment Design Options for Near-Zero-Energy Homes (NZEH) -A Stage 2 Scoping Assessment  

SciTech Connect

Although the energy efficiency of heating, ventilating, and air-conditioning (HVAC) equipment has increased substantially in recent years, new approaches are needed to continue this trend. Conventional unitary equipment and system designs have matured to a point where cost-effective, dramatic efficiency improvements that meet near-zero-energy housing (NZEH) goals require a radical rethinking of opportunities to improve system performance. The large reductions in HVAC energy consumption necessary to support the NZEH goals require a systems-oriented analysis approach that characterizes each element of energy consumption, identifies alternatives, and determines the most cost-effective combination of options. In particular, HVAC equipment must be developed that addresses the range of special needs of NZEH applications in the areas of reduced HVAC and water heating energy use, humidity control, ventilation, uniform comfort, and ease of zoning. This report describes results of a scoping assessment of HVAC system options for NZEH homes. ORNL has completed a preliminary adaptation, for consideration by The U.S. Department of Energy, Energy Efficiency and Renewable Energy Office, Building Technologies (BT) Program, of Cooper's (2001) stage and gate planning process to the HVAC and Water Heating element of BT's multi-year plan, as illustrated in Figure 1. In order to adapt to R&D the Cooper process, which is focused on product development, and to keep the technology development process consistent with an appropriate role for the federal government, the number and content of the stages and gates needed to be modified. The potential federal role in technology development involves 6 stages and 7 gates, but depending on the nature and status of the concept, some or all of the responsibilities can flow to the private sector for product development beginning as early as Gate 3. In the proposed new technology development stage and gate sequence, the Stage 2 'Scoping Assessment' provides the deliverable leading into the Gate 3 'Scoping Assessment Screen'. This report is an example of a Stage 2 deliverable written to document the screening of options against the Gate 3 criteria and to support DOE decision making and option prioritization. The objective of this scoping assessment was to perform a transparent evaluation of the HVAC system options for NZEH based on the applying the Gate 3 criteria uniformly to all options.

Baxter, Van D [ORNL

2005-11-01T23:59:59.000Z

495

Sorption and desorption characteristics of a packed bed of clay-CaCl{sub 2} desiccant particles  

Science Conference Proceedings (OSTI)

Desiccants can be used in conjunction with solar energy to provide a viable alternative to traditional air conditioning techniques. A desiccant consisting of clay and calcium chloride was developed and tested using multiple sorption and desorption cycles. During sorption, inlet air temperatures from 23 to 36 C with corresponding relative humidities of 42-66% were tested. Additionally, superficial air velocities from 0.17 to 0.85 m/s were tested. During desorption, inlet air temperatures from 50 to 57 C and superficial air velocities of approximately 0.30 and 0.60 m/s were tested. A regression equation was determined for the mass of water sorbed by the clay-CaCl2 desiccant with a R{sup 2} value of 0.917. The desorption data was regressed to an exponential function and significant k-values were determined. An equation for pressure drop through the desiccant was determined and compared to existing models. The desiccant was found to perform well during the repeated test cycles though small masses of desiccant were lost due to surface disintegration of the desiccant spheres. (author)

Tretiak, C.S.; Abdallah, N. Ben [Department of Process Engineering and Applied Science, Dalhousie University, P.O. Box 1000, Halifax, Nova Scotia (Canada)

2009-10-15T23:59:59.000Z

496

Feasibility of a solar panel-powered liquid desiccant cooling system for greenhouses.  

E-Print Network (OSTI)

??To investigate the technical feasibility of a novel cooling system for commercial greenhouses, knowledge of the state of the art in greenhouse cooling is required.… (more)

Lychnos, Georgios

2010-01-01T23:59:59.000Z

497

A model for a variable-volume, density-stratified, liquid desiccant storage tank.  

E-Print Network (OSTI)

??University of Minnesota M.S. thesis. August 2012. Major: Mechanical Engineering. Advisor: Dr. Jane H. Davidson. 1 computer file (PDF); xiv, 164 pages, appendices A-E. A… (more)

Mallinak, Jason

2012-01-01T23:59:59.000Z

498

CONFIGURATION AND FIELD TESTING OF A LIQUID DESICCANT DEHUMIDIFICATION SYSTEM FOR GREENHOUSE APPLICATIONS.  

E-Print Network (OSTI)

??Agriculture and Agri-Food Canada (AAFC), the Ontario Greenhouse Vegetable Growers Association (OGVG), and Queen’s University’s Solar Calorimetry Laboratory (SCL) are undertaking a joint project to… (more)

SEEMANN, SEAN

2013-01-01T23:59:59.000Z

499

Detection and diagnosis of faults and energy monitoring of HVAC systems with least-intrusive power analysis  

E-Print Network (OSTI)

Faults indicate degradation or sudden failure of equipment in a system. Widely existing in heating, ventilating, and air conditioning (HVAC) systems, faults always lead to inefficient energy consumption, undesirable indoor ...

Luo, Dong, 1966-

2001-01-01T23:59:59.000Z

500

Integrated Heat Pump HVAC Systems for Near-Zero-Energy Homes - Business Case Assessment  

SciTech Connect

The long range strategic goal of the Department of Energy's Building Technologies (DOE/BT) Program is to create, by 2020, technologies and design approaches that enable the construction of net-zero energy homes at low incremental cost (DOE/BT 2005). A net zero energy home (NZEH) is a residential building with greatly reduced needs for energy through efficiency gains, with the balance of energy needs supplied by renewable technologies. While initially focused on new construction, these technologies and design approaches are intended to have application to buildings constructed before 2020 as well resulting in substantial reduction in energy use for all building types and ages. DOE/BT's Emerging Technologies (ET) team is working to support this strategic goal by identifying and developing advanced heating, ventilating, air-conditioning, and water heating (HVAC/WH) technology options applicable to NZEHs. Although the energy efficiency of heating, ventilating, and air-conditioning (HVAC) equipment has increased substantially in recent years, new approaches are needed to continue this trend. Dramatic efficiency improvements are necessary to enable progress toward the NZEH goals, and will require a radical rethinking of opportunities to improve system performance. The large reductions in HVAC energy consumption necessary to support the NZEH goals require a systems-oriented analysis approach that characterizes each element of energy consumption, identifies alternatives, and determines the most cost-effective combination of options. In particular, HVAC equipment must be developed that addresses the range of special needs of NZEH applications in the areas of reduced HVAC and water heating energy use, humidity control, ventilation, uniform comfort, and ease of zoning. In FY05 ORNL conducted an initial Stage 1 (Applied Research) scoping assessment of HVAC/WH systems options for future NZEHs to help DOE/BT identify and prioritize alternative approaches for further development. Eleven system concepts with central air distribution ducting and nine multi-zone systems were selected and their annual and peak demand performance estimated for five locations: Atlanta (mixed-humid), Houston (hot-humid), Phoenix (hot-dry), San Francisco (marine), and Chicago (cold). Performance was estimated by simulating the systems using the TRNSYS simulation engine (Solar Energy Laboratory et al. 2006) in two 1800-ft{sup 2} houses--a Building America (BA) benchmark house and a prototype NZEH taken from BEopt results at the take-off (or crossover) point (i.e., a house incorporating those design features such that further progress towards ZEH is through the addition of photovoltaic power sources, as determined by current BEopt analyses conducted by NREL). Results were summarized in a project report, 'HVAC Equipment Design options for Near-Zero-Energy Homes--A Stage 2 Scoping Assessment', ORNL/TM-2005/194 (Baxter 2005). The 2005 study report describes the HVAC options considered, the ranking criteria used, and the system rankings by priority. Table 1 summarizes the energy savings potential of the highest scoring options from the 2005 study for all five locations. All system options were scored by the ORNL building equipment research team and by William Goetzler of Navigant Consulting. These scores were reviewed by DOE/BT's Residential Integration program leaders and Building America team members. Based on these results, the two centrally ducted integrated heat pump (IHP) systems (air source and ground source versions) were selected for advancement to Stage 2 (Exploratory Development) business case assessments in FY06. This report describes results of these business case assessments. It is a compilation of three separate reports describing the initial business case study (Baxter 2006a), an update to evaluate the impact of an economizer cooling option (Baxter 2006b), and a second update to evaluate the impact of a winter humidification option (Baxter 2007). In addition it reports some corrections made subsequent to release of the first two reports to correct so

Baxter, Van D [ORNL

2007-05-01T23:59:59.000Z