Powered by Deep Web Technologies
Note: This page contains sample records for the topic "lined evaporation pond" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Salinity controls on trophic interactions among invertebrates and algae of solar evaporation ponds in the Mojave Desert and relation to shorebird foraging and selenium risk  

E-Print Network [OSTI]

AMONG INVERTEBRATES AND ALGAE OF SOLAR EVAPORATION PONDS INplanktonic invertebrates and algae present along with avianof invertebrates and algae, and avian foraging were examined

Herbst, David B

2006-01-01T23:59:59.000Z

2

N-Z distributions of secondary fragments and the evaporation attractor line  

SciTech Connect (OSTI)

The process of light particle evaporation moves the position of an excited fragment in the chart of nuclides towards a line which will be called the evaporation attractor line. The predicted location of this line is parametrized and the conditions necessary for the secondary fragment distributions to reach this line are discussed. {copyright} {ital 1998} {ital The American Physical Society}

Charity, R.J. [Department of Chemistry, Washington University, St. Louis, Missouri 63130 (United States)] [Department of Chemistry, Washington University, St. Louis, Missouri 63130 (United States)

1998-08-01T23:59:59.000Z

3

Water-quality and sediment-chemistry data of drain water and evaporation ponds from Tulare Lake Drainage District, Kings County, California, March 1985 to March 1986  

SciTech Connect (OSTI)

Trace element and major ion concentrations were measured in water samples collected monthly between March 1985 and March 1986 at the MD-1 pumping station at the Tulare Lake Drainage District evaporation ponds, Kings County, California. Samples were analyzed for selected pesticides several times during the year. Salinity, as measured by specific conductance, ranged from 11,500 to 37,600 microsiemens/centimeter; total recoverable boron ranged from 4,000 to 16,000 micrg/L; and total recoverable molybdenum ranged from 630 to 2,600 microg/L. Median concentrations of total arsenic and total selenium were 97 and 2 microg/L. Atrazine, prometone, propazine, and simazine were the only pesticides detected in water samples collected at the MD-1 pumping station. Major ions, trace elements, and selected pesticides also were analyzed in water and bottom-sediment samples from five of the southern evaporation ponds at Tulare Lake Drainage District. The water samples increased in specific conductance and concentrations of total arsenic, total recoverable boron and total recoverable molybdenum going from pond 1 to pond 10, respectively. Median concentrations of total arsenic and total selenium in the bottom sediments were 4.0 and 0.9 microg/g, respectively. 6 refs., 2 figs., 12 tabs.

Fujii, R.

1988-01-01T23:59:59.000Z

4

A feasibility study of solar ponds for Wisconsin industrial process heat applications -- Impact of lining material  

SciTech Connect (OSTI)

An economic feasibility study of a salinity gradient solar pond for providing industrial process heat (IPH) in the state of Wisconsin is presented. A survey of current low temperature energy load demands of several companies within Wisconsin was completed. The data obtained was analyzed using a microcomputer based program to assess feasibility. Economic feasibility and thermal performance depends upon area. The area of the pond would determine the corresponding quantities of excavation, salt and lining material required to establish a salinity gradient solar pond (SGSP). The cost of the lining material also has a large impact upon the economic feasibility of a SGSP. The results of the economic feasibility study of a SGSP based on the selection of four types of liners is presented. These liners are a high density polyethylene (HDPE) liner, two forms of a geosynthetic clay liner (GCL) and a chemical and weather resistant polymer coated polyester fabric liner (XR-5). For a load of 10,000 GJ/month on an annual operating schedule for the most favorable economic performance resulted from a geosynthetic clay liner with a high density polyethylene backing. For a 10,000 m{sup 2} pond a payback of 8.4 years can be obtained with a unit cost of $43.20/m{sup 2}. It was also determined that if a larger load was demanded and the corresponding optimal area was provided the economic feasibility of a SGSP increased greatly. For a load of 100,000 GJ/Month on an annual operating schedule, using the same lining material, the optimal pond area was found to be 35,800 m{sup 2}, with a discounted payback of 3.8 years and a unit cost of $35.40/ms{sup 2}. Similar results were obtained for the other materials. From these findings it appears that a SGSP using a geosynthetic clay liner with HDPE backing will be economically feasible for a load of 10,000 GJ/month. The economic feasibility improves with increased thermal load and the corresponding optimal pond area.

Henning, M.A.; Reid, R.L. [Marquette Univ., Milwaukee, WI (United States). Coll. of Engineering

1995-10-01T23:59:59.000Z

5

HIGH-EFFICIENCY BACK-JUNCTION SILICON SOLAR CELL WITH AN IN-LINE EVAPORATED ALUMINUM FRONT GRID  

E-Print Network [OSTI]

HIGH-EFFICIENCY BACK-JUNCTION SILICON SOLAR CELL WITH AN IN-LINE EVAPORATED ALUMINUM FRONT GRID M-diffused back-junction emitter. The aluminum front side grid is evaporated in an industrial-type in-thick silicon shadow masks for the in-line evaporation of the aluminum front grid. The masks are fabricated

6

East Pond West Pond South Pond South Pond Southwest Pond  

Office of Legacy Management (LM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarlyEnergyDepartment ofDepartment ofof EnergyYou$0.C. 20545*. . : '* FEB1f\l p :.; . I, 18 vWest Pond

7

RESULTS OF CAUSTIC DISSOLUTION OF ALUMINOSILICATE SCALE AND CHARACTERIZATION DATA FOR SAMPLES FROM THE EVAPORATOR POT AND GRAVITY DRAIN LINE  

SciTech Connect (OSTI)

The build-up of sodium aluminosilicate scale in the 2H Evaporator system continues to cause operational difficulties. The use of a nitric acid cleaning operation proved successful in 2001. However, the operation required additional facilities to support spent cleaning solution neutralization and was quite costly. A proposed caustic cleaning flowsheet has many advantages over the acid flowsheet. Therefore, samples were retrieved from the evaporator system (gravity drain line and pot) for both chemical and radiological characterization and dissolution testing. The characterization of these scale samples showed the presence of nitrated cancrinite along with a dehydrated zeolite. Small amounts of depleted uranium were also found in these samples as expected and the amount of uranium ranged from 0.5 wt% to 2 wt%. Dissolution in sodium hydroxide solutions of various caustic concentrations showed that the scale slowly dissolves at elevated temperature (90 C). Data from similar testing indicate that the scale removed from the GDL in 2005 dissolves slower than that removed in 1997. Differences in the particle size of these samples of scale may well explain the measured dissolution rate differences.

Wilmarth, B; Rita Sullivan, R; Chris Martino, C

2006-08-21T23:59:59.000Z

8

Contact line deposits in an evaporating drop Robert D. Deegan, Olgica Bakajin, Todd F. Dupont, Greg Huber, Sidney R. Nagel, and Thomas A. Witten  

E-Print Network [OSTI]

Contact line deposits in an evaporating drop Robert D. Deegan, Olgica Bakajin, Todd F. Dupont, Greg, 68.10.Jy, 47.55.Dz, 83.70.Hq I. INTRODUCTION The residue left when coffee dries on the countertop on washed glassware, banded deposits of salt on the sidewalk during winter, and enhanced edges in water

Deegan, Robert

9

An evaluation of atmospheric evaporation for treating wood preserving wastes  

E-Print Network [OSTI]

i. hat a constant rate of total organi carbon and chemical oxygen demand removal occurred as the wastewai. r was evaporated. A procedure for designing atmospheric evaporation ponds was developed and applied to a hypothetical wood preserving plant.... From this example design estimates of equivalent hydrocarbon concentrations in the air downwind of the pond are made. Various other design con- siderations such as the input data, modifications to the design pro- cedure, solids accumulation...

Shack, Pete A

1976-01-01T23:59:59.000Z

10

Geosynthetics in a salinity-gradient solar pond environment  

SciTech Connect (OSTI)

This paper describes the latest in salinity-gradient solar pond lining systems. The high-temperature, high-salinity environment unique to a salinity-gradient solar pond resulted in failure of the geomembrane liner at the El Paso Solar Pond Test Facility after only eight years of operation. Research involved in pond reconstruction led to the selection of a lining system consisting of a flexible polypropylene (PP) geomembrane for the sidewalls and a specially formulated geosynthetic clay liner (GCL) on the bottom of the pond. The two liners have been installed and a comprehensive test program is being conducted to measure their performance. The environment encountered in a salinity-gradient solar pond will be discussed as well as material selection criteria and the design of the two liners. Preliminary results of the GCL performance monitoring will also be presented.

Lichwardt, M.A.; Comer, A.I.

1997-11-01T23:59:59.000Z

11

Dual manifold heat pipe evaporator  

DOE Patents [OSTI]

An improved evaporator section for a dual manifold heat pipe. Both the upper and lower manifolds can have surfaces exposed to the heat source which evaporate the working fluid. The tubes in the tube bank between the manifolds have openings in their lower extensions into the lower manifold to provide for the transport of evaporated working fluid from the lower manifold into the tubes and from there on into the upper manifold and on to the condenser portion of the heat pipe. A wick structure lining the inner walls of the evaporator tubes extends into both the upper and lower manifolds. At least some of the tubes also have overflow tubes contained within them to carry condensed working fluid from the upper manifold to pass to the lower without spilling down the inside walls of the tubes.

Adkins, Douglas R. (Albuquerque, NM); Rawlinson, K. Scott (Albuquerque, NM)

1994-01-01T23:59:59.000Z

12

Dual manifold heat pipe evaporator  

DOE Patents [OSTI]

An improved evaporator section is described for a dual manifold heat pipe. Both the upper and lower manifolds can have surfaces exposed to the heat source which evaporate the working fluid. The tubes in the tube bank between the manifolds have openings in their lower extensions into the lower manifold to provide for the transport of evaporated working fluid from the lower manifold into the tubes and from there on into the upper manifold and on to the condenser portion of the heat pipe. A wick structure lining the inner walls of the evaporator tubes extends into both the upper and lower manifolds. At least some of the tubes also have overflow tubes contained within them to carry condensed working fluid from the upper manifold to pass to the lower without spilling down the inside walls of the tubes. 1 figure.

Adkins, D.R.; Rawlinson, K.S.

1994-01-04T23:59:59.000Z

13

Awakening Seed Pond Water ChemistryAwakening Seed Pond Water Chemistry Our Question: Is our pond polluted?Our Question: Is our pond polluted?  

E-Print Network [OSTI]

Awakening Seed Pond Water ChemistryAwakening Seed Pond Water Chemistry Our Question: Is our pond polluted?Our Question: Is our pond polluted? Our InvestigationOur Investigation We discussed what kinds of pollutants we should look for. We narrowed down the aspects of pond chemistry that we would investigate

Hall, Sharon J.

14

Performance testing of the Sandy Pond HVDC converter terminal  

SciTech Connect (OSTI)

Results of several performance tests for the 1,800 MW Sandy Pond HVDC converter terminal are presented and discussed. The work progressed during 1990 and 1991 and included tests for power line carrier interference, audible sound, ac and dc line faults and dc harmonic performance. The testing was conducted as part of the commissioning program for the first stage of the Quebec-New England Phase 2 multi-terminal system. In this stage, the Radisson (Quebec) and Sandy Pond (New England) terminals are operational.

Donahue, J.A.; Fisher, D.A.; Railing, B.D.; Tatro, P.J. (New England Power Service Co., Westborough, MA (United States))

1993-01-01T23:59:59.000Z

15

Solar Ponds - What Are They?  

E-Print Network [OSTI]

Solar ponds can provide low cost solar energy collection as well as low temperature heat storage. Currently there are two types of solar ponds in an advanced state of development in the U.S. Each system uses a different collection and energy storage...

Anderson, A. L.

1980-01-01T23:59:59.000Z

16

Modeling of shallow stabilization ponds  

SciTech Connect (OSTI)

A two-dimensional hydrodynamic model is used to simulate shallow stabilization ponds. The model computes the flow field and the concentration distribution of a conservative tracer in the entire area of a pond. The location and the size of the dead zones, the bypassing, and the recirculating areas are also determined by the model. The numerical results are in good agreement with the experimental data obtained in the laboratory.

Babarutsi, S.; Marchand, P.; Safieddine, T.

1999-07-01T23:59:59.000Z

17

216-B-3 expansion ponds closure plan  

SciTech Connect (OSTI)

This document describes the activities for clean closure under the Resource Conservation and Recovery Act of 1976 (RCRA) of the 216-B-3 Expansion Ponds. The 216-B-3 Expansion Ponds are operated by the US Department of Energy, Richland Operations Office (DOE-RL) and co-operated by Westinghouse Hanford Company (Westinghouse Hanford). The 216-B-3 Expansion Ponds consists of a series of three earthen, unlined, interconnected ponds that receive waste water from various 200 East Area operating facilities. The 3A, 3B, and 3C ponds are referred to as Expansion Ponds because they expanded the capability of the B Pond System. Waste water (primarily cooling water, steam condensate, and sanitary water) from various 200 East Area facilities is discharged to the Bypass pipe (Project X-009). Water discharged to the Bypass pipe flows directly into the 216-B-3C Pond. The ponds were operated in a cascade mode, where the Main Pond overflowed into the 3A Pond and the 3A Pond overflowed into the 3C Pond. The 3B Pond has not received waste water since May 1985; however, when in operation, the 3B Pond received overflow from the 3A Pond. In the past, waste water discharges to the Expansion Ponds had the potential to have contained mixed waste (radioactive waste and dangerous waste). The radioactive portion of mixed waste has been interpreted by the US Department of Energy (DOE) to be regulated under the Atomic Energy Act of 1954; the dangerous waste portion of mixed waste is regulated under RCRA.

Not Available

1994-10-01T23:59:59.000Z

18

Measure Guideline: Evaporative Condensers  

SciTech Connect (OSTI)

The purpose of this measure guideline on evaporative condensers is to provide information on a cost-effective solution for energy and demand savings in homes with cooling loads. This is a prescriptive approach that outlines selection criteria, design and installation procedures, and operation and maintenance best practices. This document has been prepared to provide a process for properly designing, installing, and maintaining evaporative condenser systems as well as understanding the benefits, costs, and tradeoffs.

German, A.; Dakin, B.; Hoeschele, M.

2012-03-01T23:59:59.000Z

19

Evaporation of extrasolar planets  

E-Print Network [OSTI]

This article presents a review on the observations and theoretical modeling of the evaporation of extrasolar planets. The observations and the resulting constraints on the upper atmosphere (thermosphere and exosphere) of the "hot-Jupiters". are described. The early observations of the first discovered transiting extrasolar planet, HD209458b, allowed the discovery that this planet has an extended atmosphere of escaping hydrogen. Subsequent observations showed the presence of oxygen and carbon at very high altitude. These observations give unique constraints on the escape rate and mechanism in the atmosphere of hot-Jupiters. The most recent Lyman-alpha HST observations of HD189733b and MgII observations of Wasp-12b allow for the first time comparison of the evaporation from different planets in different environments. Models to quantify the escape rate from the measured occultation depths, and an energy diagram to describe the evaporation state of hot-Jupiters are presented. Using this diagram, it is shown that...

Etangs, A Lecavelier des

2012-01-01T23:59:59.000Z

20

Evaporative oxidation treatability test report  

SciTech Connect (OSTI)

In 1992, Congress passed the Federal Facilities Compliance Act that requires the U.S. Department of Energy (DOE) to treat and dispose of its mixed waste in accordance with the Resource Conservation and Recovery Act (RCRA) land disposal restrictions (LDRs). In response to the need for mixed-waste treatment capacity where available off-site commercial treatment facilities do not exist or cannot be used, the DOE Albuquerque Operations Office (DOE-AL) organized a Treatment Selection Team to match mixed wastes with treatment options and develop a strategy for treatment of its mixed wastes. DOE-AL manages operations at nine sites with mixed-waste inventories. The Treatment Selection Team determined a need to develop mobile treatment capacity to treat wastes at the sites where the wastes are generated. Treatment processes used for mixed waste not only must address the hazardous component (i.e., meet LDRs) but also must contain the radioactive component in a form that allows final disposal while protecting workers, the public, and the environment. On the basis of recommendations of the Treatment Selection Team, DOE-AL assigned projects to the sites to bring mixed-waste treatment capacity on-line. The three technologies assigned to the DOE Grand Junction Projects Office (GJPO) are evaporative oxidation, thermal desorption, and treated wastewater evaporation. Rust Geotech, the DOE-GJPO prime contractor, was assigned to design and fabricate mobile treatment units (MTUs) for these three technologies and to deliver the MTUs to selected DOE-AL sites. To conduct treatability tests at the GJPO, Rust leased a pilot-scale evaporative oxidation unit from the Clemson Technical Center (CTC), Anderson, South Carolina. The purpose of this report is to document the findings and results of tests performed using this equipment.

NONE

1995-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "lined evaporation pond" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Hot air drum evaporator  

DOE Patents [OSTI]

An evaporation system for aqueous radioactive waste uses standard 30 and 55 gallon drums. Waste solutions form cascading water sprays as they pass over a number of trays arranged in a vertical stack within a drum. Hot dry air is circulated radially of the drum through the water sprays thereby removing water vapor. The system is encased in concrete to prevent exposure to radioactivity. The use of standard 30 and 55 gallon drums permits an inexpensive compact modular design that is readily disposable, thus eliminating maintenance and radiation build-up problems encountered with conventional evaporation systems.

Black, Roger L. (Idaho Falls, ID)

1981-01-01T23:59:59.000Z

22

Pond Management Update Register by: October 16!!!  

E-Print Network [OSTI]

Pond Management Update Register by: October 16!!! Tri-County Extension Programming October 18, 2012 Bradford County FFA Farm 3165 N.W. 196th St. Starke, FL 32091 4:00 PM Registration 4:30 Hot Dog Dinner 5:00 Calculating Pond Dimensions Dr. Mike Davis, CED, Baker County 5:25 Water Quality Basil Bactawar, CED, Union

Watson, Craig A.

23

100-D Ponds closure plan. Revision 1  

SciTech Connect (OSTI)

The 100-D Ponds is a Treatment, Storage, and Disposal (TSD) unit on the Hanford Facility that received both dangerous and nonregulated waste. This Closure Plan (Rev. 1) for the 100-D Ponds TSD unit consists of a RCRA Part A Dangerous Waste Permit Application (Rev. 3), a RCRA Closure Plan, and supporting information contained in the appendices to the plan. The closure plan consists of eight chapters containing facility description, process information, waste characteristics, and groundwater monitoring data. There are also chapters containing the closure strategy and performance standards. The strategy for the closure of the 100-D Ponds TSD unit is clean closure. Appendices A and B of the closure plan demonstrate that soil and groundwater beneath 100-D Ponds are below cleanup limits. All dangerous wastes or dangerous waste constituents or residues associated with the operation of the ponds have been removed, therefore, human health and the environment are protected. Discharges to the 100-D Ponds, which are located in the 100-DR-1 operable unit, were discontinued in June 1994. Contaminated sediment was removed from the ponds in August 1996. Subsequent sampling and analysis demonstrated that there is no contamination remaining in the ponds, therefore, this closure plan is a demonstration of clean closure.

Petersen, S.W.

1997-09-01T23:59:59.000Z

24

Stocking and Management Recommendations for Texas Farm Ponds.  

E-Print Network [OSTI]

. For example, what size pond is to be stocked? Generally, ponds less than one acre receive different recommendations than larger ponds. The extent of water surface fluctuations, degree of expected fishing pressure and the muddiness of the water are a few... balance between bass and forage. Spawning devices may be installed to encourage reproduction of catfish. Expect most or all of the reproduction to be removed by bass, particularly in clear ponds. In muddy or turbid ponds, more catfish will avoid bass...

Anonymous,

1983-01-01T23:59:59.000Z

25

Closure report for CAU 93: Area 6 steam cleaning effluent ponds, Nevada Test Site. Volume 1  

SciTech Connect (OSTI)

The Steam Cleaning Effluent Ponds (SCEP) waste unit is located in Area 6 at the Nevada Test Site. The SCEPs are evaporation basins formerly used for the disposal of untreated liquid effluent discharged from steam cleaning activities associated with Buildings 6-623 and 6-800. This closure report documents the strategy and analytical results that support the clean closure or closure in place of each of the components within CAU 93. In addition, the report documents all deviations from the approved closure plan and provides rationale for all deviations.

NONE

1997-12-01T23:59:59.000Z

26

Tank 26F-2F Evaporator Study  

SciTech Connect (OSTI)

Tank 26F supernate sample was sent by Savannah River Remediation to Savannah River National Laboratory for evaporation test to help understand the underlying cause of the recent gravity drain line (GDL) pluggage during operation of the 2F Evaporator system. The supernate sample was characterized prior to the evaporation test. The evaporation test involved boiling the supernate in an open beaker until the density of the concentrate (evaporation product) was between 1.4 to 1.5 g/mL. It was followed by filtering and washing of the precipitated solids with deionized water. The concentrate supernate (or concentrate filtrate), the damp unwashed precipitated solids, and the wash filtrates were characterized. All the precipitated solids dissolved during water washing. A semi-quantitative X-ray diffraction (XRD) analysis on the unwashed precipitated solids revealed their composition. All the compounds with the exception of silica (silicon oxide) are known to be readily soluble in water. Hence, their dissolution during water washing is not unexpected. Even though silica is a sparingly water-soluble compound, its dissolution is also not surprising. This stems from its small fraction in the solids as a whole and also its relative freshness. Assuming similar supernate characteristics, flushing the GDL with water (preferably warm) should facilitate dissolution and removal of future pluggage events as long as build up/aging of the sparingly soluble constituent (silica) is limited. On the other hand, since the amount of silica formed is relatively small, it is quite possible dissolution of the more soluble larger fraction will cause disintegration or fragmentation of the sparingly soluble smaller fraction (that may be embedded in the larger soluble solid mass) and allow its removal via suspension in the flushing water.

Adu-Wusu, K.

2012-12-19T23:59:59.000Z

27

Solar Roof Cooling by Evaporation  

E-Print Network [OSTI]

SOLAR ROOF COOLING BY EVAPORATION Fanjet Evaporative Roof Cooling Windsor Lake Landing #1 Windsor Point Road Columbia, S.C. 29206 G. V. Patterson National Sales Manager Evaporation is nature's way of cooling. By the The American Society... penetration through will include current engineering techniques, sys out the course of the day. tem designs and documented cases of 20% to 30% reduction in air-conditioning run time. Dr. John Yellott of the Yellott Solar Energy Labo ratories in Phoenix...

Patterson, G. V.

1982-01-01T23:59:59.000Z

28

Vacuum flash evaporated polymer composites  

DOE Patents [OSTI]

A method for fabrication of polymer composite layers in a vacuum is disclosed. More specifically, the method of dissolving salts in a monomer solution, vacuum flash evaporating the solution, condensing the flash evaporated solution as a liquid film, and forming the condensed liquid film into a polymer composite layer on a substrate is disclosed.

Affinito, J.D.; Gross, M.E.

1997-10-28T23:59:59.000Z

29

Experimental nursery pond cultivation of the seagrass Halodule beaudettei  

E-Print Network [OSTI]

Experiments were conducted from April through July of hics. l 998 to assess the cultivation of Halodule beaudettei (den Hartog) den Hartog (shoal-grass) in experimental nursery ponds. The effects of pond flow-regime, water turbidity, culture media...

Rosen, David J.

1998-01-01T23:59:59.000Z

30

Sealing Ponds and Lakes with Bentonite  

E-Print Network [OSTI]

of 1 pound per square foot will require two bags of 50 pounds each in each square (each square contains 100 square feet). Large ponds or lakes may require the bentonite to be delivered to the site in bulk quantities. Spread the bentonite even- ly over... of Bentonite to Use The amount of bentonite required to effectively reduce seepage losses from a pond or lake varies from 1 to 2 pounds per square foot of soil surface. One-half pound of bentonite per square foot of soil is usually satisfactory when the bottom...

Lesikar, Bruce J.

2003-04-01T23:59:59.000Z

31

Retrieval of Melt Pond Coverage from MODIS using Optimal Estimation  

E-Print Network [OSTI]

results showed an error in melt pond coverage estimation of 1.1%. The technique was then applied to Svalbard sea ice over the 2003 melt season to produce an estimate of melt pond coverage evolution. This melt pond evolution showed a similar general trend...

Dodd, Emma

2011-11-24T23:59:59.000Z

32

Fish Grubs in Freshwater Ponds and Lakes.  

E-Print Network [OSTI]

rooc Z TA245.7 8873 N0.1380 r--- u ----!i -- B-1380 Fish Grubs in Freshwater Ponds and Lakes Sterling K. Johnson* Fish grubs are the immature forms of parasitic worms that invade the flesh of fishes. Grubs appear as round or bead...

Johnson, Sterling K.

1981-01-01T23:59:59.000Z

33

Heat extraction from salinity-gradient solar ponds using heat pipe heat exchangers  

SciTech Connect (OSTI)

This paper presents the results of experimental and theoretical analysis on the heat extraction process from solar pond by using the heat pipe heat exchanger. In order to conduct research work, a small scale experimental solar pond with an area of 7.0 m{sup 2} and a depth of 1.5 m was built at Khon Kaen in North-Eastern Thailand (16 27'N102 E). Heat was successfully extracted from the lower convective zone (LCZ) of the solar pond by using a heat pipe heat exchanger made from 60 copper tubes with 21 mm inside diameter and 22 mm outside diameter. The length of the evaporator and condenser section was 800 mm and 200 mm respectively. R134a was used as the heat transfer fluid in the experiment. The theoretical model was formulated for the solar pond heat extraction on the basis of the energy conservation equations and by using the solar radiation data for the above location. Numerical methods were used to solve the modeling equations. In the analysis, the performance of heat exchanger is investigated by varying the velocity of inlet air used to extract heat from the condenser end of the heat pipe heat exchanger (HPHE). Air velocity was found to have a significant influence on the effectiveness of heat pipe heat exchanger. In the present investigation, there was an increase in effectiveness by 43% as the air velocity was decreased from 5 m/s to 1 m/s. The results obtained from the theoretical model showed good agreement with the experimental data. (author)

Tundee, Sura; Terdtoon, Pradit; Sakulchangsatjatai, Phrut [Department of Mechanical Engineering, Faculty of Engineering, Chiang Mai University, Chiang Mai 50200 (Thailand); Singh, Randeep; Akbarzadeh, Aliakbar [Energy Conservation and Renewable Energy Group, School of Aerospace, Mechanical and Manufacturing Engineering, RMIT University, Bundoora East Campus, Bundoora, Victoria 3083 (Australia)

2010-09-15T23:59:59.000Z

34

EVIDENCE OF EXPLOSIVE EVAPORATION IN A MICROFLARE OBSERVED BY HINODE/EIS  

SciTech Connect (OSTI)

We present a detailed study of explosive chromospheric evaporation during a microflare which occurred on 2007 December 7 as observed with the Extreme-ultraviolet Imaging Spectrometer on board Hinode. We find temperature-dependent upflows for lines formed from 1.0 to 2.5 MK and downflows for lines formed from 0.05 to 0.63 MK in the impulsive phase of the flare. Both the line intensity and the nonthermal line width appear enhanced in most of the lines and are temporally correlated with the evaporation velocity. Our results are consistent with the numerical simulations of flare models, which take into account a strong nonthermal electron beam in producing the explosive chromospheric evaporation. The explosive evaporation observed in this microflare implies that the same dynamic processes may exist in events with very different magnitudes.

Chen, F.; Ding, M. D., E-mail: dmd@nju.edu.c [Department of Astronomy, Nanjing University, Nanjing 210093 (China)

2010-11-20T23:59:59.000Z

35

Evaporative Cooling for Energy Conservation  

E-Print Network [OSTI]

The evaporative cooling principle applies to all equipment that exchanges sensible heat for latent heat. Equipment of this type falls into two general categories: (1) equipment for heat rejection, such as cooling towers and (2) equipment for air...

Meyer, J. R.

1983-01-01T23:59:59.000Z

36

DWPF Recycle Evaporator Simulant Tests  

SciTech Connect (OSTI)

Testing was performed to determine the feasibility and processing characteristics of an evaporation process to reduce the volume of the recycle stream from the Defense Waste Processing Facility (DWPF). The concentrated recycle would be returned to DWPF while the overhead condensate would be transferred to the Effluent Treatment Plant. Various blends of evaporator feed were tested using simulants developed from characterization of actual recycle streams from DWPF and input from DWPF-Engineering. The simulated feed was evaporated in laboratory scale apparatus to target a 30X volume reduction. Condensate and concentrate samples from each run were analyzed and the process characteristics (foaming, scaling, etc) were visually monitored during each run. The following conclusions were made from the testing: Concentration of the ''typical'' recycle stream in DWPF by 30X was feasible. The addition of DWTT recycle streams to the typical recycle stream raises the solids content of the evaporator feed considerably and lowers the amount of concentration that can be achieved. Foaming was noted during all evaporation tests and must be addressed prior to operation of the full-scale evaporator. Tests were conducted that identified Dow Corning 2210 as an antifoam candidate that warrants further evaluation. The condensate has the potential to exceed the ETP WAC for mercury, silicon, and TOC. Controlling the amount of equipment decontamination recycle in the evaporator blend would help meet the TOC limits. The evaporator condensate will be saturated with mercury and elemental mercury will collect in the evaporator condensate collection vessel. No scaling on heating surfaces was noted during the tests, but splatter onto the walls of the evaporation vessels led to a buildup of solids. These solids were difficult to remove with 2M nitric acid. Precipitation of solids was not noted during the testing. Some of the aluminum present in the recycle streams was converted from gibbsite to aluminum oxide during the evaporation process. The following recommendations were made: Recycle from the DWTT should be metered in slowly to the ''typical'' recycle streams to avoid spikes in solids content to allow consistent processing and avoid process upsets. Additional studies should be conducted to determine acceptable volume ratios for the HEME dissolution and decontamination solutions in the evaporator feed. Dow Corning 2210 antifoam should be evaluated for use to control foaming. Additional tests are required to determine the concentration of antifoam required to prevent foaming during startup, the frequency of antifoam additions required to control foaming during steady state processing, and the ability of the antifoam to control foam over a range of potential feed compositions. This evaluation should also include evaluation of the degradation of the antifoam and impact on the silicon and TOC content of the condensate. The caustic HEME dissolution recycle stream should be neutralized to at least pH of 7 prior to blending with the acidic recycle streams. Dow Corning 2210 should be used during the evaporation testing using the radioactive recycle samples received from DWPF. Evaluation of additional antifoam candidates should be conducted as a backup for Dow Corning 2210. A camera and/or foam detection instrument should be included in the evaporator design to allow monitoring of the foaming behavior during operation. The potential for foam formation and high solids content should be considered during the design of the evaporator vessel.

Stone, M

2005-04-05T23:59:59.000Z

37

A comparison of Nannochloropsis salina growth performance in two outdoor pond designs: conventional raceways versus the ARID pond with superior temperature management  

DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

A comparison of Nannochloropsis salina growth performance in two outdoor pond designs: conventional raceways versus the ARID pond with superior temperature management

Crowe, Braden [Pacific Northwest National Laboratory; Attalah, Said [University of Arizona; Agrawal, Shweta [University of Arizona; Waller, Peter [University of Arizona; Ryan, Randy [University of Arizona.edu; Van Wagenen, Jon [Pacific Northwest National Laboratory; Chavis, Aaron [Pacific Northwest National Laboratory; Kyndt, John [University of Arizona; Kacira, Murat [University of Arizona; Ogden, Kim L. [University of Arizona; Huesemann, Michael [Pacific Northwest National Laboratory

2012-01-01T23:59:59.000Z

38

A rational approach for evaluation and screening of treatment and disposal options for the solar pond sludges at Rocky Flats  

SciTech Connect (OSTI)

This document consists of information about the treatment options for the sludge that is located in the evaporation ponds at the Rocky Flats Plant. The sludges are mixed low-level radioactive wastes whose composition and character were variable. Sludges similar to these are typically treated prior to ultimate disposal. Disposal of treated sludges includes both on-site and off-site options. The rational approach described in this paper is useful for technology evaluation and screening because it provides a format for developing objectives, listing alternatives, and weighing the alternatives against the objectives and against each other.

Dickerson, K.S.

1995-12-31T23:59:59.000Z

39

Simulation of multicomponent evaporation in electron beam melting and refining  

SciTech Connect (OSTI)

Experimental results and a mathematical model are presented to describe differential evaporation rates in electron beam melting of titanium alloys containing aluminum and vanadium. Experiments characterized the evaporation rate of commercially pure titanium, and vapor composition over titanium with up to 6% Al and 4.5% V content as a function of beam power, scan frequency and background pressure. The model is made up of a steady-state heat and mass transport model of a melting hearth and a model of transient thermal and flow behavior near the surface. Activity coefficients for aluminum and vanadium in titanium are roughly estimated by fitting model parameters to experimental results. Based on the ability to vary evaporation rate by 10-15% using scan frequency alone, we discuss the possibility of on-line composition control by means of intelligent manipulation of the electron beam.

Powell, A.; Szekely, J. [Massachusetts Inst. of Tech., Cambridge, MA (United States); Van Den Avyle, J.; Damkroger, B. [Sandia National Labs., Albuquerque, NM (United States)

1996-06-01T23:59:59.000Z

40

Classification and waterfowl use of ponds in south Texas  

E-Print Network [OSTI]

LITERATURE REVIEW STUDY AREA 10 pond Formation 12 METHODS RESULTS 13 26 Pond Suruey Pond Classification Water Quality Vegetation Classification System Estuarine/intertidal/unconsolidated shore Lacustrine/limnetic/aquatic bed Lacustrine/litton'al/unconsolidated... bottom Lacustrine/littoral/aquatic bed Lacustrine/littoral/unconsolidated shore Lacustrine/limnetic s littoral/ aquatic bed Lacustrine/limnetic a littoral/ unconsolidated shore a uncon- solidated bottom 26 33 33 38 41 46 46 49 49 50 51...

McAdams, Matthew Stephen

2012-06-07T23:59:59.000Z

Note: This page contains sample records for the topic "lined evaporation pond" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Solar Roof Cooling by Evaporation  

E-Print Network [OSTI]

It is generally recognized that as much as 60% of the air conditioning load in a building is generated by solar heat from the roof. This paper on SOLAR ROOF COOLING BY EVAPORATION is presented in slide form, tracing the history of 'nature's way...

Patterson, G. V.

1981-01-01T23:59:59.000Z

42

Across the Pond Newsletter Issue 1  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power Systems EngineeringDepartment of EnergyAbout Us » FAQsUCNIOF ENERGY ACROSS THE POND

43

Across the Pond Newsletter Issue 2  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power Systems EngineeringDepartment of EnergyAbout Us » FAQsUCNIOF ENERGY ACROSS THE POND-

44

2101-M Pond hydrogeologic characterization report  

SciTech Connect (OSTI)

This report documents information collected by the Pacific Northwest Laboratory {sup (a)} at the request of Westinghouse Hanford Company. Presented in this report is the interpretation of the hydrogeologic environment at the 2101-M Pond, located in the 200-East Area of the Hanford Site. This information and its accompanying interpretation were derived from sampling and testing activities associated with the installation of four ground-water monitoring wells, in addition to data gathered from several previously existing wells. The new monitoring wells were installed as part of a groundwater monitoring program initiated in 1988. The four new monitoring wells were installed around the 2101-M Pond between May 23 and August 27, 1988. Geologic sampling, aquifer testing, and initial ground-water sampling were performed during the installation of these wells. Laboratory analyses of the sediment samples for particle size, calcium carbonate content, and selected natural and contaminant constituents were performed. A full year of quarterly ground-water sampling and the first statistical analysis of background and downgradient data have also been performed. 112 refs., 49 figs., 18 tabs.

Chamness, M.A.; Luttrell, S.P.; Bates, D.J.; Martin, W.J.

1990-09-01T23:59:59.000Z

45

Conductive Thermal Interaction in Evaporative Cooling Process  

E-Print Network [OSTI]

be considered. Usually the dry-bulb depression performed by an evaporative cooler depends solely on the ambient wet-bulb temperature. The cool underground water in an evaporative cooler can cause not only adiabatic evaporation but also sensible heat transfer...

Kim, B. S.; Degelman, L. O.

1990-01-01T23:59:59.000Z

46

Dynamics of evaporative colloidal patterning  

E-Print Network [OSTI]

Drying suspensions often leave behind complex patterns of particulates, as might be seen in the coffee stains on a table. Here we consider the dynamics of periodic band or uniform solid film formation on a vertical plate suspended partially in a drying colloidal solution. Direct observations allow us to visualize the dynamics of the band and film deposition, and the transition in between when the colloidal concentration is varied. A minimal theory of the liquid meniscus motion along the plate reveals the dynamics of the banding and its transition to the filming as a function of the ratio of deposition and evaporation rates. We also provide a complementary multiphase model of colloids dissolved in the liquid, which couples the inhomogeneous evaporation at the evolving meniscus to the fluid and particulate flows and the transition from a dilute suspension to a porous plug. This allows us to determine the concentration dependence of the bandwidth and the deposition rate. Together, our findings allow for the control of drying-induced patterning as a function of the colloidal concentration and evaporation rate.

C. Nadir Kaplan; Ning Wu; Shreyas Mandre; Joanna Aizenberg; L. Mahadevan

2014-12-04T23:59:59.000Z

47

Fuel Pond Sludge - Lessons Learned from Initial De-sludging of Sellafield's Pile Fuel Storage Pond - 12066  

SciTech Connect (OSTI)

The Pile Fuel Storage Pond (PFSP) at Sellafield was built and commissioned between the late 1940's and early 1950's as a storage and cooling facility for irradiated fuel and isotopes from the two Windscale Pile reactors. The pond was linked via submerged water ducts to each reactor, where fuel and isotopes were discharged into skips for transfer along the duct to the pond. In the pond the fuel was cooled then de-canned underwater prior to export for reprocessing. The plant operated successfully until it was taken out of operation in 1962 when the First Magnox Fuel Storage Pond took over fuel storage and de-canning operations on the site. The pond was then used for storage of miscellaneous Intermediate Level Waste (ILW) and fuel from the UK's Nuclear Programme for which no defined disposal route was available. By the mid 1970's the import of waste ceased and the plant, with its inventory, was placed into a passive care and maintenance regime. By the mid 1990s, driven by the age of the facility and concern over the potential challenge to dispose of the various wastes and fuels being stored, the plant operator initiated a programme of work to remediate the facility. This programme is split into a number of key phases targeted at sustained reduction in the hazard associated with the pond, these include: - Pond Preparation: Before any remediation work could start the condition of the pond had to be transformed from a passive store to a plant capable of complex retrieval operations. This work included plant and equipment upgrades, removal of redundant structures and the provision of a effluent treatment plant for removing particulate and dissolved activity from the pond water. - Canned Fuel Retrieval: Removal of canned fuel, including oxide and carbide fuels, is the highest priority within the programme. Handling and export equipment required to remove the canned fuel from the pond has been provided and treatment routes developed utilising existing site facilities to allow the fuel to be reprocessed or conditioned for long term storage. - Sludge Retrieval: In excess of 300 m{sup 3} of sludge has accumulated in the pond over many years and is made up of debris arising from fuel and metallic corrosion, wind blown debris and bio-organic materials. The Sludge Retrieval Project has provided the equipment necessary to retrieve the sludge, including skip washer and tipper machines for clearing sludge from the pond skips, equipment for clearing sludge from the pond floor and bays, along with an 'in pond' corral for interim storage of retrieved sludge. Two further projects are providing new plant processing routes, which will initially store and eventually passivate the sludge. - Metal Fuel Retrieval: Metal Fuel from early Windscale Pile operations and various other sources is stored within the pond; the fuel varies considerably in both form and condition. A retrieval project is planned which will provide fuel handling, conditioning, sentencing and export equipment required to remove the metal fuel from the pond for export to on site facilities for interim storage and disposal. - Solid Waste Retrieval: A final retrieval project will provide methods for handling, retrieval, packaging and export of the remaining solid Intermediate Level Waste within the pond. This includes residual metal fuel pieces, fuel cladding (Magnox, aluminium and zircaloy), isotope cartridges, reactor furniture, and miscellaneous activated and contaminated items. Each of the waste streams requires conditioning to allow it to be and disposed of via one of the site treatment plants. - Pond Dewatering and Dismantling: Delivery of the above projects will allow operations to progressively remove the radiological inventory, thereby reducing the hazard/risk posed by the plant. This will then allow subsequent dewatering of the pond and dismantling of the structure. (authors)

Carlisle, Derek; Adamson, Kate [Sellafield Ltd, Sellafield, Cumbria (United Kingdom)

2012-07-01T23:59:59.000Z

48

Groundwater impact assessment report for the 100-D Ponds  

SciTech Connect (OSTI)

The 183-D Water Treatment Facility (WTF) discharges effluent to the 120-0-1 Ponds (100-D Ponds) located north of the 100-D Area perimeter fence. This report satisfies one of the requirements of the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) Milestone M-17-00B as agreed by the US Department of Energy, Washington State Department of Ecology, and the US Environmental Protection Agency. Tri-Party Agreement Milestone M-17-00B includes a requirement to assess impacts to groundwater from disposal of the 183-D WTF effluent to the 100-D Ponds. In addition, the 100-D Ponds are a Resource Conservation and Recovery Act of 1976 treatment, storage, and disposal facility covered by the 100-D Ponds Closure Plan (DOE-RL 1993a). There is evidence of groundwater contamination, primarily nitrate, tritium, and chromium, in the unconfined aquifer beneath the 100-D Area and 100 Areas in general. The contaminant plumes are area wide and are a result of past-practice reactor and disposal operations in the 100-D Area currently being investigated as part of the 100-DR-1 and 100-HR-3 Operable Units (DOE-RL 1992b, 1992a). Based on current effluent conditions, continued operation of the 100-D Ponds will not adversely affect the groundwater quality in the 100-D Area. Monitoring wells near the pond have slightly higher alkaline pH values than wells in the rest of the area. Concentrations of known contaminants in these wells are lower than ambient 100-D Area groundwater conditions and exhibit a localized dilution effect associated with discharges to the pond. Hydraulic impact to the local groundwater system from these discharges is minor. The groundwater monitoring well network for the 100-D Ponds is adequate.

Alexander, D.J.

1993-07-01T23:59:59.000Z

49

Description of work for 216-U-Pond test pits  

SciTech Connect (OSTI)

This description of work (DOW) details the field activities associated with the test pit excavation and soil sampling at the 216- U-10 Pond (U-10 Pond) in the 200 West Area and will serve as a field guide for those performing the work. It will be used in conjunction with the 200-UP-2 Resource Conservation and Recovery Act of 1976 (RCRA) Facility Investigation/Corrective Measures Study (DOE-RL 1993a, [LFI]) and Site Characterization Manual (WHC 1988a). Test pits will be constructed to characterize the vertical extent of contaminants in sediments within and beneath the former U-10 pond.

Kelty, G.G.

1993-08-11T23:59:59.000Z

50

Microsoft Word - Poorman Ponds_CX Memo_20120607.docx  

Broader source: Energy.gov (indexed) [DOE]

Poorman Ponds Property Funding Fish and Wildlife Project No.: 2009-003-00 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.25 Transfer, lease, disposition,...

51

Comparative physical limnology of farm ponds in Southcentral Texas  

E-Print Network [OSTI]

. More recently Bennett (1971) also examined pond thermal dynamics. Most of his discussion, however, dealt with lakes in the northern latitudes. Much of the literature available tends to be biologically oriented. Schultz (1952) sampled one Ohio farm... than two inches in early June caused a sharp drop in temperature st all depths. However, the bottom temperatures of one pond intensively studied by Schultz (1952) in Ohio remained unchanged after a summer rainfall. Only the surface waters were...

Meyers, Dewey Gregory

1973-01-01T23:59:59.000Z

52

Apparatus and method for evaporator defrosting  

DOE Patents [OSTI]

An apparatus and method for warm-liquid defrosting of the evaporator of a refrigeration system. The apparatus includes a first refrigerant expansion device that selectively expands refrigerant for cooling the evaporator, a second refrigerant expansion device that selectively expands the refrigerant after the refrigerant has passed through the evaporator, and a defrosting control for the first refrigerant expansion device and second refrigerant expansion device to selectively defrost the evaporator by causing warm refrigerant to flow through the evaporator. The apparatus is alternately embodied with a first refrigerant bypass and/or a second refrigerant bypass for selectively directing refrigerant to respectively bypass the first refrigerant expansion device and the second refrigerant expansion device, and with the defrosting control connected to the first refrigerant bypass and/or the second refrigerant bypass to selectively activate and deactivate the bypasses depending upon the current cycle of the refrigeration system. The apparatus alternately includes an accumulator for accumulating liquid and/or gaseous refrigerant that is then pumped either to a refrigerant receiver or the first refrigerant expansion device for enhanced evaporator defrosting capability. The inventive method of defrosting an evaporator in a refrigeration system includes the steps of compressing refrigerant in a compressor and cooling the refrigerant in the condenser such that the refrigerant is substantially in liquid form, passing the refrigerant substantially in liquid form through the evaporator, and expanding the refrigerant with a refrigerant expansion device after the refrigerant substantially passes through the evaporator.

Mei, Viung C. (Oak Ridge, TN); Chen, Fang C. (Knoxville, TN); Domitrovic, Ronald E. (Knoxville, TN)

2001-01-01T23:59:59.000Z

53

Dew-Point Evaporative Comfort Cooling (Presentation)  

SciTech Connect (OSTI)

Presentation on innovative indirect evaporative cooling technology developed by Coolerado Corporation given at the Rocky Mountain Chapter ASHRAE conference in April 2012.

Dean, J.

2012-10-01T23:59:59.000Z

54

Portable brine evaporator unit, process, and system  

DOE Patents [OSTI]

The present invention discloses a comprehensive, efficient, and cost effective portable evaporator unit, method, and system for the treatment of brine. The evaporator unit, method, and system require a pretreatment process that removes heavy metals, crude oil, and other contaminates in preparation for the evaporator unit. The pretreatment and the evaporator unit, method, and system process metals and brine at the site where they are generated (the well site). Thus, saving significant money to producers who can avoid present and future increases in transportation costs.

Hart, Paul John (Indiana, PA); Miller, Bruce G. (State College, PA); Wincek, Ronald T. (State College, PA); Decker, Glenn E. (Bellefonte, PA); Johnson, David K. (Port Matilda, PA)

2009-04-07T23:59:59.000Z

55

2101-M pond closure plan. Volume 1, Revision 2  

SciTech Connect (OSTI)

This document describes activities for the closure of a surface impoundment (2101-M Pond) at the Hanford Site. The 2101-H Pond was initially constructed in 1953 to serve as a drainage collection area for the 2101-H Building. (Until the Basalt Waste Isolation Project (BWIP) Laboratory was constructed in the 2101-M Building in 1979--1981, the only source contributing discharge to the pond was condensate water from the 2101-H Building heating, ventilation, and air conditioning (HVAC) system. The drains for the BWIP Laboratory rooms were plumbed into a 4-in., cast-iron, low-pressure drain pipe that carries waste water from the HVAC system to the pond. During the active life of the BWIP Laboratory, solutions of dissolved barium in groundwater samples were discharged to the 2101-M Pond via the laboratory drains. As a result of the discharges, a Part A permit application was initially submitted to the Washington State Department of Ecology (Ecology) in August 1986 which designates the 2101-M Pond as a surface impoundment.

Not Available

1993-06-01T23:59:59.000Z

56

Advanced evaporator technology progress report FY 1992  

SciTech Connect (OSTI)

This report summarizes the work that was completed in FY 1992 on the program {open_quotes}Technology Development for Concentrating Process Streams.{close_quotes} The purpose of this program is to evaluate and develop evaporator technology for concentrating radioactive waste and product streams such as those generated by the TRUEX process. Concentrating these streams and minimizing the volume of waste generated can significantly reduce disposal costs; however, equipment to concentrate the streams and recycle the decontaminated condensates must be installed. LICON, Inc., is developing an evaporator that shows a great deal of potential for this application. In this report, concepts that need to be incorporated into the design of an evaporator operated in a radioactive environment are discussed. These concepts include criticality safety, remote operation and maintenance, and materials of construction. Both solubility and vapor-liquid equilibrium data are needed to design an effective process for concentrating process streams. Therefore, literature surveys were completed and are summarized in this report. A model that is being developed to predict vapor phase compositions is described. A laboratory-scale evaporator was purchased and installed to study the evaporation process and to collect additional data. This unit is described in detail. Two new LICON evaporators are being designed for installation at Argonne-East in FY 1993 to process low-level radioactive waste generated throughout the laboratory. They will also provide operating data from a full-sized evaporator processing radioactive solutions. Details on these evaporators are included in this report.

Chamberlain, D.; Hutter, J.C.; Leonard, R.A. [and others

1995-01-01T23:59:59.000Z

57

Water Evaporation: A Transition Path Sampling Study  

E-Print Network [OSTI]

We use transition path sampling to study evaporation in the SPC/E model of liquid water. Based on thousands of evaporation trajectories, we characterize the members of the transition state ensemble (TSE), which exhibit a liquid-vapor interface with predominantly negative mean curvature at the site of evaporation. We also find that after evaporation is complete, the distributions of translational and angular momenta of the evaporated water are Maxwellian with a temperature equal to that of the liquid. To characterize the evaporation trajectories in their entirety, we find that it suffices to project them onto just two coordinates: the distance of the evaporating molecule to the instantaneous liquid-vapor interface, and the velocity of the water along the average interface normal. In this projected space, we find that the TSE is well-captured by a simple model of ballistic escape from a deep potential well, with no additional barrier to evaporation beyond the cohesive strength of the liquid. Equivalently, they are consistent with a near-unity probability for a water molecule impinging upon a liquid droplet to condense. These results agree with previous simulations and with some, but not all, recent experiments.

Patrick Varilly; David Chandler

2012-10-11T23:59:59.000Z

58

CONDENSATION AND EVAPORATION FOR THERMALLY UNEQUILIBRATED PHASES  

E-Print Network [OSTI]

CONDENSATION AND EVAPORATION FOR THERMALLY UNEQUILIBRATED PHASES R. A. Marcus1 , A. V. Fedkin2-K) equation for the rate of condensation of a gas or evaporation of a solid or liquid is used for systems, Tg, differs from that of the condensed phase, Ts . Here, we modify the H-K equation for this case

Grossman, Lawrence

59

Fundamental study of evaporation model in micron pore  

E-Print Network [OSTI]

of evaporation has not been established. The purpose of this study is to establish a method to apply the evaporation model based on the statistical rate theory for engineering application including vapor-liquid-structure intermolecular effect. The evaporation...

Oinuma, Ryoji

2004-11-15T23:59:59.000Z

60

Water Evaporation Studies in Texas.  

E-Print Network [OSTI]

69 59 3,893 Records JUL 8.83 8.33 9.64 10.99 1.65 .94 73 73 4,679 3,068 9.76 8.97 11.54 1.32 96 71 2,559 9.78 2.08 1.86 97 71 54 4,262 7.19 2.54 2.77 96 72 78 2,402 9.93 2.54 91 62 51 3,618 7.89 2.17 95 72....15 1.10 55 31 71 4,403 2.31 3.82 3.68 63 43 85 3,374 .45 48 19 3,948 1.92 2.34 58 35 75 4,870 1.64 1.54 1.73 58 33 67 3,138 Table 1 . Mean Monthly and Annual Meteorological Data for Stations from which Evaporation Records...

Patterson, R. E. (Raleigh Elwood); Bloodgood, Dean W.; Smith, R. L.

1954-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "lined evaporation pond" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Catastrophic Evaporation of Rocky Planets  

E-Print Network [OSTI]

Short-period exoplanets can have dayside surface temperatures surpassing 2000 K, hot enough to vaporize rock and drive a thermal wind. Small enough planets evaporate completely. We construct a radiative-hydrodynamic model of atmospheric escape from strongly irradiated, low-mass rocky planets, accounting for dust-gas energy exchange in the wind. Rocky planets with masses 2000 K are found to disintegrate entirely in 0.1 M_Earth/Gyr --- our model yields a present-day planet mass of < 0.02 M_Earth or less than about twice the mass of the Moon. Mass loss rates depend so strongly on planet mass that bodies can reside on close-in orbits for Gyrs with initial masses comparable to or less than that of Mercury, before entering a final short-lived phase of catastrophic mass loss (which KIC 12557548b has entered). Because this catastrophic stage lasts only up to a few percent of the planet's life, we estimate that for every object like KIC 12557548b, there should be 10--100 close-in quiescent progenitors with sub-da...

Perez-Becker, Daniel

2013-01-01T23:59:59.000Z

62

242-A evaporator safety analysis report  

SciTech Connect (OSTI)

This report provides a revised safety analysis for the upgraded 242-A Evaporator (the Evaporator). This safety analysis report (SAR) supports the operation of the Evaporator following life extension upgrades and other facility and operations upgrades (e.g., Project B-534) that were undertaken to enhance the capabilities of the Evaporator. The Evaporator has been classified as a moderate-hazard facility (Johnson 1990). The information contained in this SAR is based on information provided by 242-A Evaporator Operations, Westinghouse Hanford Company, site maintenance and operations contractor from June 1987 to October 1996, and the existing operating contractor, Waste Management Hanford (WMH) policies. Where appropriate, a discussion address the US Department of Energy (DOE) Orders applicable to a topic is provided. Operation of the facility will be compared to the operating contractor procedures using appropriate audits and appraisals. The following subsections provide introductory and background information, including a general description of the Evaporator facility and process, a description of the scope of this SAR revision,a nd a description of the basic changes made to the original SAR.

CAMPBELL, T.A.

1999-05-17T23:59:59.000Z

63

Black Hole Evaporation as a Nonequilibrium Process  

E-Print Network [OSTI]

When a black hole evaporates, there arises a net energy flow from the black hole into its outside environment due to the Hawking radiation and the energy accretion onto black hole. Exactly speaking, due to the net energy flow, the black hole evaporation is a nonequilibrium process. To study details of evaporation process, nonequilibrium effects of the net energy flow should be taken into account. In this article we simplify the situation so that the Hawking radiation consists of non-self-interacting massless matter fields and also the energy accretion onto the black hole consists of the same fields. Then we find that the nonequilibrium nature of black hole evaporation is described by a nonequilibrium state of that field, and we formulate nonequilibrium thermodynamics of non-self-interacting massless fields. By applying it to black hole evaporation, followings are shown: (1) Nonequilibrium effects of the energy flow tends to accelerate the black hole evaporation, and, consequently, a specific nonequilibrium phenomenon of semi-classical black hole evaporation is suggested. Furthermore a suggestion about the end state of quantum size black hole evaporation is proposed in the context of information loss paradox. (2) Negative heat capacity of black hole is the physical essence of the generalized second law of black hole thermodynamics, and self-entropy production inside the matter around black hole is not necessary to ensure the generalized second law. Furthermore a lower bound for total entropy at the end of black hole evaporation is given. A relation of the lower bound with the so-called covariant entropy bound conjecture is interesting but left as an open issue.

Hiromi Saida

2008-11-11T23:59:59.000Z

64

Vapor canister heater for evaporative emissions systems  

SciTech Connect (OSTI)

Automotive evaporative emissions systems use a charcoal canister to store evaporative hydrocarobn emissions. These stored vapors are later purged and burned during engine operation. Under certain conditions the engine cannot completely purge the canister of the stored fuel vapors, which results in a decreased vapor storage capacity in the canister. A self-regulating PTC (Positive Temperature Coefficient) heater has been developed to warm the purge air as it enters the canister, in order to provide thermal energy for increased release of the vapors from charcoal sites. This paper describes the construction and operation of the vapor canister heater as it relates to improved evaporative emission system performance.

Bishop, R.P.; Berg, P.G.

1987-01-01T23:59:59.000Z

65

Toxicity of stormwater treatment pond sediments to Hyalella azteca (Amphipoda)  

SciTech Connect (OSTI)

Stormwater runoff from highways and commercial, industrial, and residential areas contains a wide spectrum of pollutants including heavy metals, petroleum hydrocarbons, pesticides, herbicides, sediment, and nutrients. Recent efforts to reduce the impacts of urbanization on natural wetlands and other receiving waters have included the construction of stormwater treatment ponds and wetlands. These systems provide flood control and improve water quality through settling, adsorption, and precipitation of pollutants removing up to 95% of metals, nutrients and sediment before discharged from the site. The design of stormwater ponds to provide habitat for aquatic wildlife has prompted concern over the potential exposure of aquatic organisms to these contaminants. Aquatic sediments concentrate a wide array of organic and inorganic pollutants. Although water quality criteria may not be exceeded, organisms living in or near the sediments may be adversely affected. The availability of chemicals in sediments depends strongly on the prevailing chemistry. Physical conditions of the sediment and water quality characteristics including pH, redox potential and hardness, also influence contaminant availability. Studies have shown that heavy metals and nutrients carried by runoff concentrate in the sediment of stormwater ponds. Although several investigations have assessed the toxicity of sediments in streams receiving urban runoff, there have been few studies of the toxicity of stormwater treatment pond sediments to aquatic organisms. This study was part of a large-scale assessment of the contaminant hazards of stormwater treatment ponds. The objective of this study was to evaluate the toxicity of sediments and water from stormwater ponds over a 10-d period to juvenile Hyalella azteca. Bioassay results were related to concentrations of acid volatile sulfides and metals of the tested sediments. 17 refs., 4 tabs.

Karouna-Renier, N.K. [Patuxent Wildlife Research Center, Laurel, MD (United States)] [Patuxent Wildlife Research Center, Laurel, MD (United States); [Univ. of Maryland, Baltimore, MD (United States); Sparling, D.W. [Patuxent Wildlife Research Center, Laurel, MD (United States)] [Patuxent Wildlife Research Center, Laurel, MD (United States)

1997-04-01T23:59:59.000Z

66

An Internet survey of private pond owners and managers in Texas  

E-Print Network [OSTI]

pond owners got the information they used to deal with pond management problems. A secondary emphasis of the project was to examine the potential presented by the Internet for use in this type of information gathering and distribution for Texas...

Schonrock, April Elizabeth

2005-11-01T23:59:59.000Z

67

241-A evaporator flowsheet users manual  

SciTech Connect (OSTI)

This supporting document presents a description of the 242-A Evaporator flowsheet. Material balances are calculated for feed, slurry, and effluent streams based on input data for the feed stream.

Larrick, A.P.

1994-12-22T23:59:59.000Z

68

VELOCITY CHARACTERISTICS OF EVAPORATED PLASMA USING HINODE/EUV IMAGING SPECTROMETER  

SciTech Connect (OSTI)

This paper presents a detailed study of chromospheric evaporation using the EUV Imaging Spectrometer (EIS) onboard Hinode in conjunction with hard X-ray (HXR) observations from Reuven Ramaty High-Energy Solar Spectroscopic Imager (RHESSI). The advanced capabilities of EIS were used to measure Doppler shifts in 15 emission lines covering the temperature range T = 0.05-16 MK during the impulsive phase of a C-class flare on 2007 December 14. Blueshifts indicative of the evaporated material were observed in six emission lines from Fe XIV-XXIV (2-16 MK). Upflow velocity (v{sub up}) was found to scale with temperature as v{sub up} (km s{sup -1}) {approx} 8-18T(MK). Although the hottest emission lines, Fe XXIII and Fe XXIV, exhibited upflows of >200 km s{sup -1}, their line profiles were found to be dominated by a stationary component in contrast to the predictions of the standard flare model. Emission from O VI-Fe XIII lines (0.5-1.5 MK) was found to be redshifted by v{sub down} (km s{sup -1}) {approx} 60-17T (MK) and was interpreted as the downward-moving 'plug' characteristic of explosive evaporation. These downflows occur at temperatures significantly higher than previously expected. Both upflows and downflows were spatially and temporally correlated with HXR emission observed by RHESSI that provided the properties of the electron beam deemed to be the driver of the evaporation. The energy flux of the electron beam was found to be {approx}>5 x 10{sup 10} erg cm{sup -2} s{sup -1}, consistent with the value required to drive explosive chromospheric evaporation from hydrodynamic simulations.

Milligan, Ryan O.; Dennis, Brian R. [Solar Physics Laboratory (Code 671), Heliophysics Science Division, NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States)

2009-07-10T23:59:59.000Z

69

Biomass and productivity of trematode parasites in pond ecosystems  

E-Print Network [OSTI]

Biomass and productivity of trematode parasites in pond ecosystems Daniel L. Preston*, Sarah A often measure the biomass and productivity of organisms to understand the importance of populations and dissections of over 1600 aquatic invertebrate and amphib- ian hosts, we calculated the ecosystem-level biomass

Johnson, Pieter

70

Sediment management in sustainable urban drainage system ponds  

E-Print Network [OSTI]

Sediment management in sustainable urban drainage system ponds K.V. Heal*, D.A. Hepburn** and R.lunn@strath.ac.uk) Abstract Since removal and disposal of sustainable urban drainage system (SUDS) sediment can incur high maintenance costs, assessments of sediment volumes, quality and frequency of removal are required. Sediment

Heal, Kate

71

Managing Florida Ponds for Fishing 1 Charles E. Cichra2  

E-Print Network [OSTI]

CIR802 Managing Florida Ponds for Fishing 1 Charles E. Cichra2 1. This document is CIR802, one-out and impounded waters, limerock pits, and sand or gravel pits, commonly called borrow pits. Fishing pressure in fishing as a source of recreation and food. Competition for public fishery resources, coupled

Watson, Craig A.

72

Groundwater impact assessment report for the 284-WB Powerplant Ponds  

SciTech Connect (OSTI)

As required by the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement Milestone M-17-00A), this report assesses the impact of wastewater discharged to the 284-WB Powerplant Ponds on groundwater quality. The assessment reported herein expands upon the initial analysis conducted between 1989 and 1990 for the Liquid Effluent Study Final Project Plan.

Alexander, D.J.; Johnson, V.G.; Lindsey, K.A.

1993-09-01T23:59:59.000Z

73

X] THEPROPAGATIONOF BLACK BASS IN PONDS. BY WILLIAM F. PAGE,  

E-Print Network [OSTI]

X] THEPROPAGATIONOF BLACK BASS IN PONDS. BY WILLIAM F. PAGE, Superintendent U.S. Fish Commission to add to the fish supply by broadening the habitat of the black bass. But while fish-culturists were States, engaged in fish-culture were annually, at the period of the bass spawning, devoting every energy

74

Ball feeder for replenishing evaporator feed  

DOE Patents [OSTI]

Vapor source material such as uranium, which is to be dropped into a melt in an evaporator, is made into many balls of identical diameters and placed inside a container. An elongated sloping pipe is connected to the container and leads to the evaporator such that these balls can travel sequentially therealong by gravity. A metering valve in this pipe for passing these balls one at a time is opened in response to a signal when it is ascertained by a detector that there is a ball ready to be passed. A gate in the pipe near the evaporator momentarily stops the motion of the traveling ball and is then opened to allow the ball drop into the melt at a reduced speed.

Felde, David K. (Oak Ridge, TN); McKoon, Robert H. (San Ramon, CA)

1993-01-01T23:59:59.000Z

75

Ball feeder for replenishing evaporator feed  

DOE Patents [OSTI]

Vapor source material such as uranium, which is to be dropped into a melt in an evaporator, is made into many balls of identical diameters and placed inside a container. An elongated sloping pipe is connected to the container and leads to the evaporator such that these balls can travel sequentially therealong by gravity. A metering valve in this pipe for passing these balls one at a time is opened in response to a signal when it is ascertained by a detector that there is a ball ready to be passed. A gate in the pipe near the evaporator momentarily stops the motion of the traveling ball and is then opened to allow the ball drop into the melt at a reduced speed.

Felde, D.K.; McKoon, R.H.

1993-03-23T23:59:59.000Z

76

DWPF RECYCLE EVAPORATOR FLOWSHEET EVALUATION (U)  

SciTech Connect (OSTI)

The Defense Waste Processing Facility (DWPF) converts the high level waste slurries stored at the Savannah River Site into borosilicate glass for long-term storage. The vitrification process results in the generation of approximately five gallons of dilute recycle streams for each gallon of waste slurry vitrified. This dilute recycle stream is currently transferred to the H-area Tank Farm and amounts to approximately 1,400,000 gallons of effluent per year. Process changes to incorporate salt waste could increase the amount of effluent to approximately 2,900,000 gallons per year. The recycle consists of two major streams and four smaller streams. The first major recycle stream is condensate from the Chemical Process Cell (CPC), and is collected in the Slurry Mix Evaporator Condensate Tank (SMECT). The second major recycle stream is the melter offgas which is collected in the Off Gas Condensate Tank (OGCT). The four smaller streams are the sample flushes, sump flushes, decon solution, and High Efficiency Mist Eliminator (HEME) dissolution solution. These streams are collected in the Decontamination Waste Treatment Tank (DWTT) or the Recycle Collection Tank (RCT). All recycle streams are currently combined in the RCT and treated with sodium nitrite and sodium hydroxide prior to transfer to the tank farm. Tank Farm space limitations and previous outages in the 2H Evaporator system due to deposition of sodium alumino-silicates have led to evaluation of alternative methods of dealing with the DWPF recycle. One option identified for processing the recycle was a dedicated evaporator to concentrate the recycle stream to allow the solids to be recycled to the DWPF Sludge Receipt and Adjustment Tank (SRAT) and the condensate from this evaporation process to be sent and treated in the Effluent Treatment Plant (ETP). In order to meet process objectives, the recycle stream must be concentrated to 1/30th of the feed volume during the evaporation process. The concentrated stream must be pumpable to the DWPF SRAT vessel and should not precipitate solids to avoid fouling the evaporator vessel and heat transfer coils. The evaporation process must not generate excessive foam and must have a high Decontamination Factor (DF) for many species in the evaporator feed to allow the condensate to be transferred to the ETP. An initial scoping study was completed in 2001 to evaluate the feasibility of the evaporator which concluded that the concentration objectives could be met. This initial study was based on initial estimates of recycle concentration and was based solely on OLI modeling of the evaporation process. The Savannah River National Laboratory (SRNL) has completed additional studies using simulated recycle streams and OLI{reg_sign} simulations. Based on this work, the proposed flowsheet for the recycle evaporator was evaluated for feasibility, evaporator design considerations, and impact on the DWPF process. This work was in accordance with guidance from DWPF-E and was performed in accordance with the Technical Task and Quality Assurance Plan.

Stone, M

2005-04-30T23:59:59.000Z

77

Evaporative cooling enhanced cold storage system  

DOE Patents [OSTI]

The invention provides an evaporatively enhanced cold storage system wherein a warm air stream is cooled and the cooled air stream is thereafter passed into contact with a cold storage unit. Moisture is added to the cooled air stream prior to or during contact of the cooled air stream with the cold storage unit to effect enhanced cooling of the cold storage unit due to evaporation of all or a portion of the added moisture. Preferably at least a portion of the added moisture comprises water condensed during the cooling of the warm air stream.

Carr, Peter (Cary, NC)

1991-01-01T23:59:59.000Z

78

Direct Evaporative Precooling Model and Analysis  

SciTech Connect (OSTI)

Evaporative condenser pre-cooling expands the availability of energy saving, cost-effective technology options (market engagement) and serves to expedite the range of options in upcoming codes and equipment standards (impacting regulation). Commercially available evaporative pre-coolers provide a low cost retrofit for existing packaged rooftop units, commercial unitary split systems, and air cooled chillers. We map the impact of energy savings and peak energy reduction in the 3 building types (medium office, secondary school, and supermarket) in 16 locations for three building types with four pad effectivenesses and show the effect for HVAC systems using either refrigerants R22 or R410A

Shen, Bo [ORNL; Ally, Moonis Raza [ORNL; Rice, C Keith [ORNL; Craddick, William G [ORNL

2011-01-01T23:59:59.000Z

79

Evaporative cooling enhanced cold storage system  

DOE Patents [OSTI]

The invention provides an evaporatively enhanced cold storage system wherein a warm air stream is cooled and the cooled air stream is thereafter passed into contact with a cold storage unit. Moisture is added to the cooled air stream prior to or during contact of the cooled air stream with the cold storage unit to effect enhanced cooling of the cold storage unit due to evaporation of all or a portion of the added moisture. Preferably at least a portion of the added moisture comprises water condensed during the cooling of the warm air stream. 3 figures.

Carr, P.

1991-10-15T23:59:59.000Z

80

Hot air drum evaporator. [Patent application  

DOE Patents [OSTI]

An evaporation system for aqueous radioactive waste uses standard 30 and 55 gallon drums. Waste solutions form cascading water sprays as they pass over a number of trays arranged in a vertical stack within a drum. Hot dry air is circulated radially of the drum through the water sprays thereby removing water vapor. The system is encased in concrete to prevent exposure to radioactivity. The use of standard 30 and 55 gallon drums permits an inexpensive compact modular design that is readily disposable, thus eliminating maintenance and radiation build-up problems encountered with conventional evaporation systems.

Black, R.L.

1980-11-12T23:59:59.000Z

Note: This page contains sample records for the topic "lined evaporation pond" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

An environmental simulation of a shrimp mariculture pond  

E-Print Network [OSTI]

. 39 19 Zooplankton Response to Changes in ZMORT . . 20 Detritus Pool Response to Changes in ZMORT . 42 43 vln Figure Pa. ge 21 Shrimp Biomass Response to Changes in ZMORT . . 22 Shrimp Individual Body Weight Response to Changes in ZMORT... . Zooplankton 30 33 EVALUATION OF MANAGEMENT STRATEGIES . . 46 Evaluation of Stocking Densities and Feeding Rates 46 SUMMARY . REFERENCES 59 60 VITA 67 vss LIST OF FIGURES Figure Page 1 Pond Model Biomass Flows 2 Dissolved Oxygen and Population...

Whitson, John Lee

2012-06-07T23:59:59.000Z

82

Water Management for Evaporatively Cooled Condensers  

E-Print Network [OSTI]

Water Management for Evaporatively Cooled Condensers Theresa Pistochini May 23rd, 2012 ResearchAirCapacity,tons Gallons of Water Continuous Test - Outdoor Air 110-115 Deg F Cyclic Test - Outdoor Air 110-115 Deg F #12 AverageWaterHardness(ppm) Cooling Degree Days (60°F Reference) 20% Population 70% Population 10

California at Davis, University of

83

Rain on the Roof-Evaporative Spray Roof Cooling  

E-Print Network [OSTI]

This paper describes evaporative spray roof cooling systems, their components, performance and applications in various climates and building types. The evolution of this indirect evaporative cooling technique is discussed. Psychrometric and sol...

Bachman, L. R.

1985-01-01T23:59:59.000Z

84

Chemical Potential Jump during Evaporation of a Quantum Bose Gas  

E-Print Network [OSTI]

The dependence of the chemical potential jump coefficient on the evaporation coefficient is analyzed for the case in which the evaporating component is a Bose gas. The concentration of the evaporating component is assumed to be much lower than the concentration of the carrier gas. The expression for the chemical potential jump is derived from the analytic solution of the problem for the case in which the collision frequency of molecules of the evaporating component is constant.

E. A. Bedrikova; A. V. Latyshev

2013-01-07T23:59:59.000Z

85

Distribution of Arsenic in Presque Isle, PA, Pond Sediments Jason Murnock, Master of Science Candidate,  

E-Print Network [OSTI]

Distribution of Arsenic in Presque Isle, PA, Pond Sediments Jason Murnock, Master of Science........................................................................................ 3 Arsenic in Soil & Sediments......................................................................................... 12 Sediment Digestion and Analysis

Short, Daniel

86

E-Print Network 3.0 - area process ponds Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ecology 7 Tracing anthropogenic nutrient inputs into coastal plain ponds on an urban-rural gradient: a study using stable Summary: Tracing anthropogenic nutrient inputs into...

87

E-Print Network 3.0 - asian yellow pond Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Chapter 19, verse 10), and ornamental fish... ponds appear in paintings from ancient Egypt. European aqua- culture began sometime in the Middle Ages... and transformed the "art"...

88

EVAPORATIVE COOLING - CONCEPTUAL DESIGN FOR ATLAS SCT  

E-Print Network [OSTI]

The conceptual design of an evaporative two-phase flow cooling system for the ATLAS SCT detector is described, using perfluorinated propane (C3F8) as a coolant. Comparison with perfluorinated butane (C4F10) is made, although the detailed design is presented only for C3F8. The two-phase pressure drop and heat transfer coefficient are calculated in order to determine the dimensions of the cooling pipes and module contacts for the Barrel SCT. The region in which the flow is homogeneous is determined. The cooling cycle, pipework, compressor, heat exchangers and other main elements of the system are calculated in order to be able to discuss the system control, safety and reliability. Evaporative cooling appears to be substantially better than the binary ice system from the point of view of safety, reliability, detector thickness, heat transfer coefficient, cost and simplicity.

Niinikoski, T O

1998-01-01T23:59:59.000Z

89

Evaporative Cooling Basics | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy UsageAUDITVehiclesTanklessDOJExamination Laboratory -Evaporative Cooling Basics

90

Analysis Of 2H-Evaporator Scale Pot Bottom Sample [HTF-13-11-28H  

SciTech Connect (OSTI)

Savannah River Remediation (SRR) is planning to remove a buildup of sodium aluminosilicate scale from the 2H-evaporator pot by loading and soaking the pot with heated 1.5 M nitric acid solution. Sampling and analysis of the scale material from the 2H evaporator has been performed so that the evaporator can be chemically cleaned beginning July of 2013. Historically, since the operation of the Defense Waste Processing Facility (DWPF), silicon in the DWPF recycle stream combines with aluminum in the typical tank farm supernate to form sodium aluminosilicate scale mineral deposits in the 2H-evaporator pot and gravity drain line. The 2H-evaporator scale samples analyzed by Savannah River National Laboratory (SRNL) came from the bottom cone sections of the 2H-evaporator pot. The sample holder from the 2H-evaporator wall was virtually empty and was not included in the analysis. It is worth noting that after the delivery of these 2H-evaporator scale samples to SRNL for the analyses, the plant customer determined that the 2H evaporator could be operated for additional period prior to requiring cleaning. Therefore, there was no need for expedited sample analysis as was presented in the Technical Task Request. However, a second set of 2H evaporator scale samples were expected in May of 2013, which would need expedited sample analysis. X-ray diffraction analysis (XRD) confirmed the bottom cone section sample from the 2H-evaporator pot consisted of nitrated cancrinite, (a crystalline sodium aluminosilicate solid), clarkeite and uranium oxide. There were also mercury compound XRD peaks which could not be matched and further X-ray fluorescence (XRF) analysis of the sample confirmed the existence of elemental mercury or mercuric oxide. On ''as received'' basis, the scale contained an average of 7.09E+00 wt % total uranium (n = 3; st.dev. = 8.31E-01 wt %) with a U-235 enrichment of 5.80E-01 % (n = 3; st.dev. = 3.96E-02 %). The measured U-238 concentration was 7.05E+00 wt % (n=3, st. dev. = 8.25E-01 wt %). Analyses results for Pu-238 and Pu-239, and Pu-241 are 7.06E-05 {+-} 7.63E-06 wt %, 9.45E-04 {+-} 3.52E-05 wt %, and <2.24E-06 wt %, respectively. These results are provided so that SRR can calculate the equivalent uranium-235 concentrations for the NCSA. Because this 2H evaporator pot bottom scale sample contained a significant amount of elemental mercury (11.7 wt % average), it is recommended that analysis for mercury be included in future Technical Task Requests on 2H evaporator sample analysis at SRNL. Results confirm that the uranium contained in the scale remains depleted with respect to natural uranium. SRNL did not calculate an equivalent U-235 enrichment, which takes into account other fissionable isotopes U-233, Pu-239 and Pu-241.

Oji, L. N.

2013-07-15T23:59:59.000Z

91

Nuclear evaporation process with simultaneous multiparticle emission  

E-Print Network [OSTI]

The nuclear evaporation process is reformulated by taking into account simultaneous multiparticle emission from a hot compound nucleus appearing as an intermediate state in many nuclear reaction mechanisms. The simultaneous emission of many particles is particularly relevant for high excitation energy of the compound nucleus.These channels are effectively open in competition with the single particle emissions and fission in this energy regime. Indeed, the inclusion of these channels along the decay evaporating chain shows that the yield of charged particles and occurrence of fission are affected by these multiparticle emission processes of the compounded nucleus, when compared to the single sequential emission results. The effect also shows a qualitative change in the neutron multiplicity of different heavy compound nucleus considered. This should be an important aspect for the study of spallation reaction in Acceleration Driven System (ADS) reactors. The majority of neutrons generated in these reactions come from the evaporation stage of the reaction, the source of neutron for the system. A Monte Carlo simulation is employed to determine the effect of these channels on the particle yield and fission process. The relevance of the simultaneous particle emission with the increasing of excitation energy of the compound nucleus is explicitly shown.

Leonardo P. G. De Assis; Sergio B. Duarte; Bianca M. Santos

2012-08-07T23:59:59.000Z

92

Evaporated Lithium Surface Coatings in NSTX  

SciTech Connect (OSTI)

Two lithium evaporators were used to evaporate more than 100 g of lithium on to the NSTX lower divertor region. Prior to each discharge, the evaporators were withdrawn behind shutters, where they also remained during the subsequent HeGDC applied for periods up to 9.5 min. After the HeGDC, the shutters were opened and the LITERs were reinserted to deposit lithium on the lower divertor target for 10 min, at rates of 10-70 mg/min, prior to the next discharge. The major improvements in plasma performance from these lithium depositions include: 1) plasma density reduction as a result of lithium deposition; 2) suppression of ELMs; 3) improvement of energy confinement in a low-triangularity shape; 4) improvement in plasma performance for standard, high-triangularity discharges; 5) reduction of the required HeGDC time between discharges; 6) increased pedestal electron and ion temperature; 7) reduced SOL plasma density; and 8) reduced edge neutral density.

Kugel, H. W.; Mansfield, D.; Maingi, R.; Bel, M. G.; Bell, R. E.; Allain, J. P.; Gates, D.; Gerhardt, S.; Kaita, R.; Kallman, J.; Kaye, S.; LeBlanc, B.; Majeski, R.; Menard, J.; Mueller, D.; Ono, M.

2009-04-09T23:59:59.000Z

93

DIFFERENT PATTERNS OF CHROMOSPHERIC EVAPORATION IN A FLARING REGION OBSERVED WITH HINODE/EIS  

SciTech Connect (OSTI)

We investigate the chromospheric evaporation in the flare of 2007 January 16 using line profiles observed by the Exterme-UV Imaging Spectrometer on board Hinode. Three points at flare ribbons of different magnetic polarities are analyzed in detail. We find that the three points show different patterns of upflows and downflows in the impulsive phase of the flare. The spectral lines at the first point are mostly blueshifted, with the hotter lines showing a dominant blueshifted component over the stationary one. At the second point, however, only weak upflows are detected; instead, notable downflows appear at high temperatures (up to 2.5-5.0 MK). The third point is similar to the second one only in that it shows evidence of multi-component downflows. While the evaporated plasma falling back down as warm rain is a possible cause of the redshifts at the second and third points, the different patterns of chromospheric evaporation at the three points imply the existence of different heating mechanisms in the flaring active region.

Li, Y.; Ding, M. D., E-mail: dmd@nju.edu.cn [Department of Astronomy, Nanjing University, Nanjing 210093 (China)

2011-02-01T23:59:59.000Z

94

ELECTROKINETIC DENSIFICATION OF COAL FINES IN WASTE PONDS  

SciTech Connect (OSTI)

The objective of this research was to demonstrate that electrokinetics can be used to remove colloidal coal and mineral particles from coal-washing ponds and lakes without the addition of chemical additives such as salts and polymeric flocculants. The specific objectives were: Design and develop a scaleable electrophoresis apparatus to clarify suspensions of colloidal coal and clay particles; Demonstrate the separation process using polluted waste water from the coal-washing facilities at the coal-fired power plants in Centralia, WA; Develop a mathematical model of the process to predict the rate of clarification and the suspension electrical properties needed for scale up.

E. James Davis

1999-12-18T23:59:59.000Z

95

120-D-1 (100-D) ponds training plan  

SciTech Connect (OSTI)

This is the Environmental Restoration Contractor Team training plan for the 100-D Ponds treatment, storage, and disposal unit. This plan is intended to meet the requirements of WAC 173-303-330 and the Hanford Dangerous Waste Permit. The WAC 173-303-330(1)(d)(ii, v, vi) requires that personnel be familiar, where applicable, with waste feed cut-off systems, proper responses to groundwater contamination incidents, shutdown of operations, response to fire or explosion, and other process operation activities.

G. B. Mitchem

1997-12-31T23:59:59.000Z

96

MHK Projects/Twin Pond | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 No revision hasInformation Earth's Heat JumpIncMAKGalway Bay IE < MHK ProjectRose BendReachTurnbullPond <

97

E-Print Network 3.0 - arc evaporated tia1n Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Collection: Mathematics 11 Prediction of sessile drop evaporation considering surface wettability Hyunsoo Song a Summary: Prediction of sessile drop evaporation...

98

atural aquatic habitats include ponds, lakes, rivers, streams, springs, estuaries, bays, and  

E-Print Network [OSTI]

from small (ten surface acres) to large (the Great Lakes: Erie, Michigan, Huron, Ontario, and SuperiorN atural aquatic habitats include ponds, lakes, rivers, streams, springs, estuaries, bays little oxygen. Aquatic habitats can be classified as: · non-flowing waters like lakes and ponds, · slowly

Liskiewicz, Maciej

99

Hydrogeophysical investigations of the former S-3 ponds contaminant plumes, Oak Ridge Integrated Field  

E-Print Network [OSTI]

Hydrogeophysical investigations of the former S-3 ponds contaminant plumes, Oak Ridge Integrated. Hubbard4 , T. L. Mehlhorn5 , and D. B. Watson5 ABSTRACT At the Oak Ridge Integrated Field Research Challenge site, near Oak Ridge, Tennessee, contaminants from the former S-3 ponds have infiltrated

Hubbard, Susan

100

Aquatic plants growing in ponds and lakes are beneficial for fish and wildlife. They provide food,  

E-Print Network [OSTI]

cover, preventing predation, and leading to stunted (small-sized) sportfish populations. Water Weed in your pond. Constructing ponds with steep slopes that drop quickly into deep water can prevent weeds such as contour plowing, no-till farming, strip cropping, protecting shelter belts, and excluding livestock from

Liskiewicz, Maciej

Note: This page contains sample records for the topic "lined evaporation pond" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Constructed Wetlands and Waste Stabilization Ponds for municipal wastewater treatment in France: comparison of  

E-Print Network [OSTI]

13 Constructed Wetlands and Waste Stabilization Ponds for municipal wastewater treatment in France In France, vertical flow constructed wetlands and waste stabilisation ponds are both extensive treatment processes well adapted to small rural communities mainly because they are easy to operate

Paris-Sud XI, Université de

102

A model of the threedimensional evolution of Arctic melt ponds on firstyear and multiyear sea ice  

E-Print Network [OSTI]

ice. In the summer the upper layers of sea ice and snow melts producing meltwater that accumulatesA model of the threedimensional evolution of Arctic melt ponds on firstyear and multiyear sea ice F in Arctic melt ponds on the surface of sea ice. An accurate estimate of the fraction of the sea ice surface

Feltham, Daniel

103

A model of melt pond evolution on sea ice P. D. Taylor and D. L. Feltham  

E-Print Network [OSTI]

short-wave radiation. The difference in solar energy ab- sorption between pond-covered and bare sea ice Observation and Modelling, Department of Space and Climate Physics, University College London, London, UK ponds influence the summertime energy and mass balance through the albedo-feedback mechanism [Ebert

Feltham, Daniel

104

Fertilization of Fresh Water Fish Ponds 1 Craig Watson and Charles E. Cichra2  

E-Print Network [OSTI]

of larger bass because of the increased number of bluegill for them to eat. With proper fishing, the pondFA17 Fertilization of Fresh Water Fish Ponds 1 Craig Watson and Charles E. Cichra2 1. This document. If a fish species which consumes small natural foods is grown, such as the bluegill or golden shiner

Watson, Craig A.

105

Whether for aesthetics or for fishing pleasure, most pond owners are interested in stocking and  

E-Print Network [OSTI]

combination of fishes in Pennsylvania ponds. Either smallmouth or largemouth bass are suitable although ponds. Bass offer excellent sport fishing opportunities, while bluegills provide a food base for bass and good fishing for youngsters. When stocking these fish together, bass should be one year older than

Boyer, Elizabeth W.

106

Investigation of the suitability of a geosynthetic clay liner system for the El Paso Solar Pond  

SciTech Connect (OSTI)

The El Paso Solar Pond Project experienced a complete failure of its XR-5 8130 (SP) membrane liner. This paper will summarize the XR-5 8130 (SP) liner failure analysis, and provide design and installation procedures of its replacement: a geosynthetic clay liner (GCL). This application represents the first use of a GCL in a solar pond. Geosynthetic clay liners offer major advantages over membrane liners. Unlike membrane liners, clay liners are puncture-proof, have predictable permeability, and are self-healing. Furthermore, the cost of clay liners is less than that of membrane liners. However, disagreement exists as to the efficacy of clay liners in solar ponds. The high temperatures and salinity of the pond are factors which cause the most concern. Most information available for clay liners is in conjunction with municipal waste disposal facilities, although compacted clay liners have been used in Israel and Mexico for solar ponds.

Robbins, M.C.; Lu, H.; Swift, A.H.P. Jr. [Univ. of Texas, El Paso, TX (United States). Mechanical and Industrial Engineering Dept.

1995-10-01T23:59:59.000Z

107

Daily results of the initial operation of the Los Alamos salt-gradient solar pond  

SciTech Connect (OSTI)

The results of analysis of the initial data obtained on the Los Alamos National Laboratory salt-gradient solar pond, a 232 m/sup 2/ pond constructed for the primary purpose of studying pond hydrodynamics, are presented. The pond and the data-acquisition system were complete and in full operation by August 14, 1982. By September 21, 1982, the lower convecting zone had reached a temperature of 56/sup 0/C. An energy balance was performed over this period and is presented. Soil conductivity determinations have been made from the data, and the method is discussed. As a result of a leak discovered in the pond in September, a method of determining the leak rate was developed, and the results are included.

Hedstrom, J.C.; Jones, G.F.; Meyer, K.A.

1983-01-01T23:59:59.000Z

108

Treatment of evaporator condensates by pervaporation  

DOE Patents [OSTI]

A pervaporation process for separating organic contaminants from evaporator condensate streams is disclosed. The process employs a permselective membrane that is selectively permeable to an organic component of the condensate. The process involves contacting the feed side of the membrane with a liquid condensate stream, and withdrawing from the permeate side a vapor enriched in the organic component. The driving force for the process is the in vapor pressure across the membrane. This difference may be provided for instance by maintaining a vacuum on the permeate side, or by condensing the permeate. The process offers a simple, economic alternative to other separation techniques.

Blume, Ingo (Hengelq, NL); Baker, Richard W. (Palo Alto, CA)

1990-01-01T23:59:59.000Z

109

Sediments in marsh ponds of the Gulf Coast Chenier Plain: effects of structural marsh management and salinity  

E-Print Network [OSTI]

Sediments in marsh ponds of the Gulf Coast Chenier Plain: effects of structural marsh management: impoundments, marsh sediments, ponds, salinity Abstract Physical characteristics of sediments in coastal marsh compositions of waterbird communities. Sediments in marsh ponds of the Gulf Coast Chenier Plain potentially

Afton, Alan D.

110

NAME: Molokai Fish Pond & Fringing Reef Restoration LOCATION: Kaunakakai, Island of Molokai (Maui County), Hawai'i  

E-Print Network [OSTI]

NAME: Molokai Fish Pond & Fringing Reef Restoration LOCATION: Kaunakakai, Island of Molokai (Maui fish ponds on the fringing reef of the Hawaiian island of Molokai. Mangroves were planted in 1902 conditions and threaten to take over the reef flats and fish ponds. EXPECTED BENEFITS: Fine sediment flushed

US Army Corps of Engineers

111

Evaporation of Water from Particles in the Aerodynamic Lens Inlet...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

of Water from Particles in the Aerodynamic Lens Inlet: An Experimental Study. Evaporation of Water from Particles in the Aerodynamic Lens Inlet: An Experimental Study. Abstract:...

112

Studies on the Ecological Impact of Evaporation Retardation Monolayers  

E-Print Network [OSTI]

TR-6 1966 Studies on the Ecological Impact of Evaporation Retardation Monolayers B.G. Wixson Texas Water Resources Institute Texas A&M University ...

Wixson, B.G.

113

ELECTROKINETIC DENSIFICATION OF COAL FINES IN WASTE PONDS  

SciTech Connect (OSTI)

The objective of this research is to demonstrate that electrokinetics can be used to remove colloidal coal and mineral particles from coal-washing ponds and lakes without the addition of chemical additives such as salts and polymeric flocculants. In this experimental and analytical study the authors elucidate the transport processes that control the rate of concentrated colloidal particle removal, demonstrate the process on a laboratory scale, and develop the scale-up laws needed to design commercial-scale processes. The authors are also addressing the fundamental problems associated with particle-particle interactions (electrical and hydrodynamic), the effects of particle concentration on the applied electric field, the electrochemical reactions that occur at the electrodes, and the prediction of power requirements.

E. James Davis

1998-05-01T23:59:59.000Z

114

Groundwater Monitoring Plan for the Hanford Site 216-B-3 Pond RCRA Facility  

SciTech Connect (OSTI)

The 216-B-3 Pond system was a series of ponds used for disposal of liquid effluent from past Hanford production facilities. In operation from 1945 to 1997, the B Pond System has been a Resource Conservation and Recovery Act (RCRA) facility since 1986, with RCRA interim-status groundwater monitoring in place since 1988. In 1994 the expansion ponds of the facility were clean closed, leaving only the main pond and a portion of the 216-B-3-3 ditch as the currently regulated facility. In 2001, the Washington State Department of Ecology (Ecology) issued a letter providing guidance for a two-year, trial evaluation of an alternate, intrawell statistical approach to contaminant detection monitoring at the B Pond system. This temporary variance was allowed because the standard indicator-parameters evaluation (pH, specific conductance, total organic carbon, and total organic halides) and accompanying interim status statistical approach is ineffective for detecting potential B-Pond-derived contaminants in groundwater, primarily because this method fails to account for variability in the background data and because B Pond leachate is not expected to affect the indicator parameters. In July 2003, the final samples were collected for the two-year variance period. An evaluation of the results of the alternate statistical approach is currently in progress. While Ecology evaluates the efficacy of the alternate approach (and/or until B Pond is incorporated into the Hanford Facility RCRA Permit), the B Pond system will return to contamination-indicator detection monitoring. Total organic carbon and total organic halides were added to the constituent list beginning with the January 2004 samples. Under this plan, the following wells will be monitored for B Pond: 699-42-42B, 699-43-44, 699-43-45, and 699-44-39B. The wells will be sampled semi-annually for the contamination indicator parameters (pH, specific conductance, total organic carbon, and total organic halides) and annually for water quality parameters (chloride, iron, manganese, phenols, sodium, and sulfate). This plan will remain in effect until superseded by another plan or until B Pond is incorporated into the Hanford Facility RCRA Permit.

Barnett, D BRENT.; Smith, Ronald M.; Chou, Charissa J.; McDonald, John P.

2005-11-01T23:59:59.000Z

115

Maintenance Guide for Greenhouse Ventilation, Evaporative Cooling Heating Systems1  

E-Print Network [OSTI]

when the need is discovered, but a good preventive maintenance program will reduce the number. This fact sheet will emphasize corrective and preventive maintenance procedures for ventilation, evaporativeAE26 Maintenance Guide for Greenhouse Ventilation, Evaporative Cooling Heating Systems1 D. E

Watson, Craig A.

116

Evaporative Hydrochloric Acid Recovery: Something Old, Something New...  

E-Print Network [OSTI]

. If zinc is present from the pickling of galvanizing racks or stripping of parts, the zinc concentration will range from as low as zinc chloride solution remains. In the evaporative process of the Hydrochloric Acid Recovery System, the waste acid is pumped through a pre-filter into the evaporator section oftI1e recovery system. This solution is heated by means...

Cullivan, B.

117

Forward-backward emission of target evaporated evaporated fragments at high energy nucleus-nucleus collisions  

E-Print Network [OSTI]

The multiplicity distribution, multiplicity moment, scaled variance, entropy and reduced entropy of target evaporated fragment emitted in forward and backward hemispheres in 12 A GeV $^{4}$He, 3.7 A GeV $^{16}$O, 60 A GeV $^{16}$O, 1.7 A GeV $^{84}$Kr and 10.7 A GeV $^{197}$Au induced emulsion heavy targets (AgBr) interactions are investigated. It is found that the multiplicity distribution of target evaporated fragments emitted in forward and backward hemispheres can be fitted by a Gaussian distribution. The multiplicity moments of target evaporated particles emitted in forward and backward hemispheres increase with the order of the moment {\\em q}, and second-order multiplicity moment is energy independent over the entire energy for all the interactions in the forward and backward hemisphere respectively. The scaled variance, a direct measure of multiplicity fluctuations, is close to one for all the interactions which may be said that there is a feeble correlation among the produced particles. The entropy of...

Zhang, Zhi; Zhang, Dong-Hai

2015-01-01T23:59:59.000Z

118

Texas AgriLife Research with General Atomics Pilots Microalgae Ponds in Pecos BIOENERGY PROGRAM  

E-Print Network [OSTI]

Texas AgriLife Research with General Atomics Pilots Microalgae Ponds in Pecos BIOENERGY PROGRAM on the tank bottom will be opened. The Continued on back #12;http://AgBioenergy.tamu.edu concentrated algae

119

Is degradation of the herbicide atrazine enhanced in turfgrass pond sediments  

E-Print Network [OSTI]

To further understand the fate of atrazine, a herbicide of public concern in the environment, this study was undertaken to determine if atrazine degradation potential is increased in turfgrass ponds having a history of repeated exposure...

Shourds, Shalyn Wayne

2001-01-01T23:59:59.000Z

120

A landscape approach to reserving farm ponds for wintering bird refuges in Taoyuan, Taiwan  

E-Print Network [OSTI]

regression with error back-propagation into the paradigm of artificial neural networks (ANN). The model considers pond shape, size, neighboring farmlands, and developed areas in calculating parameters pertaining to their respective and interactive influences...

Fang, Wei-Ta

2006-08-16T23:59:59.000Z

Note: This page contains sample records for the topic "lined evaporation pond" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

40 CFR 265 interim-status ground-water monitoring plan for the 2101-M pond  

SciTech Connect (OSTI)

This report outlines a ground-water monitoring plan for the 2101-M pond, located in the southwestern part of the 200-East Area on the Hanford Site in south-central Washington State. It has been determined that hazardous materials may have been discharged to the pond. Installation of an interim-status ground-water monitoring system is required under the Resource Conservation and Recovery Act to determine if hazardous chemicals are moving out of the pond. This plan describes the location of new wells for the monitoring system, how the wells are to be completed, the data to be collected, and how those data can be used to determine the source and extent of any ground-water contamination from the 2101-M pond. Four new wells are planned, one upgradient and three downgradient. 35 refs., 12 figs., 9 tabs.

Chamness, M.A.; Luttrell, S.P.; Dudziak, S.

1989-03-01T23:59:59.000Z

122

Oxygen, carbon, and sulfur cycling in the sediments of hyper-eutrophic mesocosms (shrimp mariculture ponds)  

E-Print Network [OSTI]

for the individual incubations in season 1 was 167. 86 ml Op m ~ hr ' in pond 5 on sand on August 1 (trip 5) and the low was 35. 24 mi Op m ~ hr ' in pond 6 on sand on July 3 (trip 3) In season 2 the highest rate observed was 236. 13 ml 02 m ~ hr ' in pond 6... to 124. 35 ml Op m. ~ hr. t on trip four and then fell to 112. 04 ml Os m ~ hr. 1 on trip five. During season two, SOD was much more variable, starting at 88. 87 ml Op m-~ hr-1 and reaching a maximum of 145. 49 ml Os m-s hr-1 on Sept. 25. In pond five...

Ellis, Matthew Stewart

1992-01-01T23:59:59.000Z

123

Factors influencing algal biomass in hydrologically dynamic salt ponds in a subtropical salt marsh  

E-Print Network [OSTI]

realized, underscoring the importance of understanding algal dynamics in such systems. Benthic and planktonic chlorophyll-a (surrogate for total algal biomass), sediment AFDW, total suspended solids, salinity, and nutrients were examined in marsh ponds...

Miller, Carrie J.

2009-05-15T23:59:59.000Z

124

Impact of population and latrines on fecal contamination of ponds in rural Bangladesh  

E-Print Network [OSTI]

. Due to poor sanitation, ponds receive fecal contaminatio-based methods and E. coli, Bacteroidales and adenovirus using quantitative PCR. Population and sanitation focused on safe drinking water, as well as improved sanitation and hygiene (Esrey, 1996; Pruss et al

van Geen, Alexander

125

The growth of Tilapia aurea in ponds receiving laying hen wastes  

E-Print Network [OSTI]

THE GROWTH OF TILAPIA AUREA IN PONDS RECEIVING LAYING HEN WASTES A Thesis by ROBERT PAUL BURNS Submitted to the Graduate College of Texas A&M University in partial fulfillment of the requirement for the degree of. MASTER OF SCIENCE December... 1978 Major Subject: Wildlife and Fisheries Sciences THE GROWTH OF TILAPIA AUREA IN PONDS RECEIVING LAYING HEN WASTES A Thesis by ROBERT PAUL BURNS Approved as to style and content by: (Cha' man o ittee) Memb r Member) Head of Department...

Burns, Robert Paul

1978-01-01T23:59:59.000Z

126

216-U-10 Pond and 216-Z-19 Ditch characterization studies  

SciTech Connect (OSTI)

The chemical, reprocessing of spent nuclear fuels at the US Department of Energy`s Hanford Site has generated large volumes of radioactive liquid effluents. The majority of these effluents have been used strictly for cooling or other supportive functions and have been discharged to ditches and ponds. The 216-U-10 Pond and 216-Z-19 Ditch are two such disposal facilities. These facilities are components of an integrated system of ditches, ponds, and overflow facilities collectively referred to as the U-Pond disposal system. The U-Pond system has been used since 1943 and has received a large variety of radioisotopes from several sources. This study covered tho major aspects of the environment, including wind resuspension, biological uptake and transport, geologic distribution in surface and subsurface sediments, and ground-water impacts. The long-term use of U-Pond and the Z-19 Ditch has resulted in the localized accumulation of transuranic and fission product inventories as a result of sorption and filtration of particulates onto the uppermost sediments.

Last, G.V.; Duncan, D.W.; Graham, M.J.; Hall, M.D.; Hall, V.W.; Landeen, D.S.; Leitz, J.G.; Mitchell, R.M.

1994-02-01T23:59:59.000Z

127

Application of the TXM system to EB evaporation of alloys -- an update  

SciTech Connect (OSTI)

High Rate E.B. evaporation of alloys with volatile components demands a sophisticated process control to obtain the required layer composition as well as the required deposition rate. In recent years, the analysis of X-radiation emitted from the melting bath of an electron beam facility has been successfully investigated in relation with real time determination of bath composition. X-ray analytical on-line measurements during E.B. evaporation of alloys show that the bath composition is indicative of material feed and layer composition. By the X-ray analytical monitoring of the bath composition the layer composition as well as the deposition rate can be controlled. The TXM-System offers a way to put this approach into effect for high power industrial applications. High analysing accuracies can be achieved. In addition the integration of the TXM-System into the E.B. evaporation as well as E.B. melting technology of a producer permits him to understand better the interaction between process parameters and alloy composition.

Schiller, N. [Fraunhofer Institute Electron Beam and Plasma Technology, Dresden (Germany)

1994-12-31T23:59:59.000Z

128

Report on the culture of brown shrimp, Penaeus aztecus, in ponds receiving thermal effluent from a power plant  

E-Print Network [OSTI]

. (December 1974) Donald Martin Quarberg, B. S. , University of Wisconsin--Stevens Point Chairman of Advisory Committee: Dr. David V. Aldrich During 1973 brown shrimp, Penaeus aztecus, were cultured in 0. 1 ha ponds designed to receive a constant supply... pond study in early August and the other was terminated in mid- September. Survival was under 0. 5%, growth less than 0. 6 mm/day, and production only 0. 53 and 1. 59 kg/ha. In September two ponds were each stocked with 50, two ponds with 500...

Quarberg, Donald Martin

1974-01-01T23:59:59.000Z

129

Self-excited hydrothermal waves in evaporating sessile drops  

E-Print Network [OSTI]

Pattern formation driven by the spontaneous evaporation of sessile drops of methanol, ethanol, and FC-72 using infrared thermography is observed and, in certain cases, interpreted in terms of hydrothermal waves. Both methanol and ethanol drops...

Sefiane K.; Moffat J.R.; Matar O.K.; Craster R.V.

2008-08-01T23:59:59.000Z

130

Evaporative Roof Cooling- A Simple Solution to Cut Cooling Costs  

E-Print Network [OSTI]

Since the Energy Crisis Evaporative Roof Cooling Systems have gained increased acceptance as a cost effective method to reduce the high cost of air conditioning. Documented case histories in retro-fit installations show direct energy savings...

Abernethy, D.

131

Potential of Evaporative Cooling Systems for Buildings in India  

E-Print Network [OSTI]

Evaporative cooling potential for building in various climatic zones in India is investigated. Maintainable indoor conditions are obtained from the load - capacity analysis for the prevailing ambient conditions. For the assumed activity level...

Maiya, M. P.; Vijay, S.

2010-01-01T23:59:59.000Z

132

Evaporative Roof Cooling - A Simple Solution to Cut Cooling Costs  

E-Print Network [OSTI]

Since the "Energy Crisis" Evaporative Roof Cooling Systems have gained increased acceptance as a cost effective method to reduce the high cost of air conditioning. Documented case histories in retrofit installations show direct energy savings...

Abernethy, D.

1985-01-01T23:59:59.000Z

133

On Reducing Evaporator Superheat Nonlinearity with Control Architecture  

E-Print Network [OSTI]

, and refrigeration VCC vapor compression cycle TEV thermostatic expansion valve EEV electronic expansion valve HEV hybrid expansion valve PID proportional-integral-derivative P, Pevap evaporator pressure Q(s) transfer function from PSET to evaporator superheat (inner... by a number of different valve types, which vary in expense and design KFM product of KF times KM(v) KU gain from HEV position to mechanical pressure setpoint U HEV position MEMS micro-electrical-mechanical systemsregulating device also known...

Elliot, M.S.; Rasmussen, B.P.

134

Thermodynamics and evaporation of the noncommutative black hole  

E-Print Network [OSTI]

We investigate the thermodynamics of the noncommutative black hole whose static picture is similar to that of the nonsingular black hole known as the de Sitter-Schwarzschild black hole. It turns out that the final remnant of extremal black hole is a thermodynamically stable object. We describe the evaporation process of this black hole by using the noncommutativity-corrected Vaidya metric. It is found that there exists a close relationship between thermodynamic approach and evaporation process.

Yun Soo Myung; Yong-Wan Kim; Young-Jai Park

2007-01-21T23:59:59.000Z

135

Superhydrophobic coated apparatus for liquid purification by evaporative condensation  

DOE Patents [OSTI]

Disclosed are examples of apparatuses for evaporative purification of a contaminated liquid. In each example, there is a first vessel for storing the contaminated fluid. The first vessel includes a surface coated with a layer of superhydrophobic material and the surface is at least partially in contact with the contaminated liquid. The contaminants do not adhere to the surface as the purified liquid evaporates, thus simplifying maintenance of the apparatus.

Simpson, John T; McNeany, Steve R; Dinsmore, Thomas V; Hunter, Scott R; Ivanov, Ilia N

2014-03-11T23:59:59.000Z

136

Evaporation of alpha particles from $^31$P nucleus  

E-Print Network [OSTI]

The energy spectra of alpha particles have been measured in coincidence with the evaporation residues for the decay of the compound nucleus $^31$P produced in the reaction $^19$F (96 MeV) + $^12$C. The data have been compared with the predictions of the statistical model code CASCADE. It has been observed that significant deformation effect in the compound nucleus need to be considered in order to explain the shape of the evaporated alpha particle energy spectra.

D. Bandyopadhyay; S. K. Basu; C. Bhattacharya; S. Bhattacharya; K. Krishan; A. Chatterjee; S. Kailas; A. Navin; A. Srivastava

1998-07-24T23:59:59.000Z

137

BSW process of the slowly evaporating charged black hole  

E-Print Network [OSTI]

In this paper, we study the BSW process of the slowly evaporating charged black hole. It can be found that the BSW process will also arise near black hole horizon when the evaporation of charged black hole is very slow. But now the background black hole does not have to be an extremal black hole, and it will be approximately an extremal black hole unless it is nearly a huge stationary black hole.

Liancheng Wang; Feng He; Xiangyun Fu

2015-02-09T23:59:59.000Z

138

Method and apparatus for flash evaporation of liquids  

DOE Patents [OSTI]

A vertical tube flash evaporator for introducing a superheated liquid into a flash evaporation chamber includes a vertical inlet tube with a flared diffuser portion at its upper outlet end. A plurality of annular screens are positioned in axially spaced-apart relation to each other around the periphery of the vertical tube and below the diffuser portion thereof. The screens are preferably curved upward in a cup-shaped configuration. These flash evaporators are shown in an ocean thermal energy conversion unit designed for generating electric power from differential temperature gradients in ocean water. The method of use of the flash evaporators of this invention includes flowing liquid upwardly through the vertical tube into the diffuser where initial expansion and boiling occurs quite violently and explosively. Unvaporized liquid sheets and drops collide with each other to enhance surface renewal and evaporation properties, and liquid flowing over the outlet end of the diffuser falls onto the curved screens for further surface renewal and evaporation.

Bharathan, Desikan (Lakewood, CO)

1984-01-01T23:59:59.000Z

139

Method and apparatus for flash evaporation of liquids  

DOE Patents [OSTI]

A vertical tube flash evaporator for introducing a super-heated liquid into a flash evaporation chamber includes a vertical inlet tube with a flared diffuser portion at its upper outlet end. A plurality of annular screens are positioned in axially spaced-apart relation to each other around the periphery of the vertical tube and below the diffuser portion thereof. The screens are preferably curved upward in a cup-shaped configuration. These flash evaporators are shown in an ocean thermal energy conversion unit designed for generating electric power from differential temperature gradients in ocean water. The method of use of the flash evaporators of this invention includes flowing liquid upwardly through the vertical tube into the diffuser where initial expansion and boiling occurs quite violently and explosively. Unvaporized liquid sheets and drops collide with each other to enhance surface renewal and evaporation properties, and liquid flowing over the outlet end of the diffuser falls onto the curved screens for further surface renewal and evaporation.

Bharathan, D.

1984-01-01T23:59:59.000Z

140

Salinity controls on trophic interactions among invertebrates and algae of solar evaporation ponds in the Mojave Desert and relation to shorebird foraging and selenium risk  

E-Print Network [OSTI]

contamination (Cieminski and Flake The absence of Se in brine ?brine ?y larvae Ephy- dra cinerea Jones. Archives of Environmental Contaminationbrine shrimp tis- sue Se levels in the same range as those observed here, selenium contamination

Herbst, David B

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "lined evaporation pond" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

East Pond West Pond South Pond South Pond Southwest Pond  

Office of Legacy Management (LM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarlyEnergyDepartment ofDepartment ofof EnergyYou$0.C. 20545*. . : '* FEB1f\l p :.; . I, 18 v

142

East Pond West Pond South Pond South Pond Southwest Pond  

Office of Legacy Management (LM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarlyEnergyDepartment ofDepartment ofof EnergyYou$0.C. 20545*. . : '* FEB1f\l p :.; . I, 18 vWest

143

Analysis Of 2H-Evaporator Scale Wall [HTF-13-82] And Pot Bottom [HTF-13-77] Samples  

SciTech Connect (OSTI)

Savannah River Remediation (SRR) is planning to remove a buildup of sodium aluminosilicate scale from the 2H-evaporator pot by loading and soaking the pot with heated 1.5 M nitric acid solution. Sampling and analysis of the scale material has been performed so that uranium and plutonium isotopic analysis can be input into a Nuclear Criticality Safety Assessment (NCSA) for scale removal by chemical cleaning. Historically, since the operation of the Defense Waste Processing Facility (DWPF), silicon in the DWPF recycle stream combines with aluminum in the typical tank farm supernate to form sodium aluminosilicate scale mineral deposits in the 2H-evaporator pot and gravity drain line. The 2H-evaporator scale samples analyzed by Savannah River National Laboratory (SRNL) came from two different locations within the evaporator pot; the bottom cone sections of the 2H-evaporator pot [Sample HTF-13-77] and the wall 2H-evaporator [sample HTF-13-82]. X-ray diffraction analysis (XRD) confirmed that both the 2H-evaporator pot scale and the wall samples consist of nitrated cancrinite (a crystalline sodium aluminosilicate solid) and clarkeite (a uranium oxyhydroxide mineral). On ''as received'' basis, the bottom pot section scale sample contained an average of 2.59E+00 {+-} 1.40E-01 wt % total uranium with a U-235 enrichment of 6.12E-01 {+-} 1.48E-02 %, while the wall sample contained an average of 4.03E+00 {+-} 9.79E-01 wt % total uranium with a U-235 enrichment of 6.03E-01% {+-} 1.66E-02 wt %. The bottom pot section scale sample analyses results for Pu-238, Pu-239, and Pu-241 are 3.16E-05 {+-} 5.40E-06 wt %, 3.28E-04 {+-} 1.45E-05 wt %, and <8.80E-07 wt %, respectively. The evaporator wall scale samples analysis values for Pu-238, Pu-239, and Pu-241 averages 3.74E-05 {+-} 6.01E-06 wt %, 4.38E-04 {+-} 5.08E-05 wt %, and <1.38E-06 wt %, respectively. The Pu-241 analyses results, as presented, are upper limit values. For these two evaporator scale samples obtained at two different locations within the evaporator pot the major radioactive components (on a mass basis) in the additional radionuclide analyses were Sr-90, Cs-137 Np-237, Pu-239/240 and Th-232. Small quantities of americium and curium were detected in the blanks used for Am/Cm method for these radionuclides. These trace radionuclide amounts are assumed to come from airborne contamination in the shielded cells drying or digestion oven, which has been replaced. Therefore, the Am/Cm results, as presented, may be higher than the true Am/Cm values for these samples. These results are provided so that SRR can calculate the equivalent uranium-235 concentrations for the NCSA. Results confirm that the uranium contained in the scale remains depleted with respect to natural uranium. SRNL did not calculate an equivalent U-235 enrichment, which takes into account other fissionable isotopes U-233, Pu-239 and Pu-241. The applicable method for calculation of equivalent U-235 will be determined in the NCSA. With a few exceptions, a comparison of select radionuclides measurements from this 2013 2H evaporator scale characterization (pot bottom and wall scale samples) with those measurements for the same radionuclides in the 2010 2H evaporator scale analysis shows that the radionuclide analysis for both years are fairly comparable; the analyses results are about the same order of magnitude.

Oji, L. N.

2013-09-11T23:59:59.000Z

144

Development of fluorocarbon evaporative cooling recirculators and controls for the ATLAS pixel and semiconductor tracking detectors  

E-Print Network [OSTI]

Development of fluorocarbon evaporative cooling recirculators and controls for the ATLAS pixel and semiconductor tracking detectors

Bayer, C; Bonneau, P; Bosteels, Michel; Burckhart, H J; Cragg, D; English, R; Hallewell, G D; Hallgren, Bjrn I; Kersten, S; Kind, P; Langedrag, K; Lindsay, S; Merkel, M; Stapnes, Steinar; Thadome, J; Vacek, V

2000-01-01T23:59:59.000Z

145

Upward-facing Lithium Flash Evaporator for NSTX-U  

SciTech Connect (OSTI)

NSTX plasma performance has been significantly enhanced by lithium conditioning [1]. To date, the lower divertor and passive plates have been conditioned by downward facing lithium evaporators (LITER) as appropriate for lower null plasmas. The higher power operation expected from NSTX-U requires double null plasma operation in order to distribute the heat flux between the upper and lower divertors making it desirable to coat the upper divertor region with Li as well. An upward aiming LITER (U-LITER) is presently under development and will be inserted into NSTX-U using a horizontal probe drive located in a 6" upper midplane port. In the retracted position the evaporator will be loaded with up to 300 mg of Li granules utilizing one of the calibrated NSTX Li powder droppers[2]. The evaporator will then be inserted into the vessel in a location within the shadow of the RF limiters and will remain in the vessel during the discharge. About 10 seconds before a discharge, it will be rapidly heated and the lithium completely evaporated onto the upper divertor, thus avoiding the complication of a shutter that prevents evaporation during the shot when the diagnostic shutters are open. The minimal time interval between the evaporation and the start of the discharge will avoid the passivation of the lithium by residual gases and enable the study of the conditioning effects of un-passivated Li surfaces [3]. Two methods are being investigated to accomplish the rapid (few second) heating of the lithium. A resistive method relies on passing a large current through a Li filled crucible. A second method requires using a 3 kW e-beam gun to heat the Li. In this paper the evaporator systems will be described and the pros and cons of each heating method will be discussed.

Roquemore, A. L.

2013-07-09T23:59:59.000Z

146

Fottea 8(2): 133146, 2008 133 Epipelic cyanobacteria and algae: a case study from Czech ponds  

E-Print Network [OSTI]

Fottea 8(2): 133­146, 2008 133 Epipelic cyanobacteria and algae: a case study from Czech ponds Petr and algae (particularly desmids). Altogether 45 sediment samples were taken at ponds covering a p and various protozoa, feeding on epipelic algae (Amoeba, Urceolus cyclostomus). Key words: epipelon

147

Ponding Test Results Seepage and Total Losses, North Alamo Main Canal Hidalgo County Irrigation District No. 2  

E-Print Network [OSTI]

TR-324 2008 Ponding Test Results Seepage and Total Losses, North Alamo Main Canal Hidalgo County Irrigation District No. 2 Eric Leigh Texas AgriLife Extension Associate, Biological and Agricultural... Engineering, College Station Guy Fipps Texas AgriLife Extension Professor and Extension Agricultural Engineer, Biological and Agricultural Engineering, College Station February 4, 2004 PONDING TEST RESULTS SEEPAGE AND TOTAL...

Leigh, E.; Fipps, G.

148

Ponding Test Results Seepage and Total Losses, Secondary Canals 13, 16, and 29 Donna Irrigation District Hidalgo County No. 1  

E-Print Network [OSTI]

TR-323 2008 Ponding Test Results Seepage and Total Losses, Secondary Canals 13, 16, and 29 Donna Irrigation District Hidalgo County No. 1 Eric Leigh Texas AgriLife Extension Associate, Biological... and Agricultural Engineering, College Station Guy Fipps Texas AgriLife Extension Professor and Extension Agricultural Engineer, Biological and Agricultural Engineering, College Station March 30, 2004 PONDING TEST RESULTS SEEPAGE...

Leigh, E.; Fipps, G.

149

The Use of Lime in Fish Ponds1 Andy M. Lazur, Charles E. Cichra and Craig Watson2  

E-Print Network [OSTI]

small fish are being reared. Calcite and dolomite increase the total hardness, total alkalinity, and p desirable for most freshwater fish. Water in ponds reflects the quality of the soils in which they are located. In acid soils, ponds typically have low total alkalinity, total hardness, and pH. Total hardness

Watson, Craig A.

150

Estimated Costs and Returns for Catfish Farms with Recirculating Ponds Along the Upper Texas Coast.  

E-Print Network [OSTI]

_TDOC ' Z TA24S.7 8873 NO.1704 - . , ., TEXAS A&M UNIVERSHY LIBRARY for Catfish Farms ' with Recirculating Ponds Along ? . . the Upper Texas Coast ~7'!K~fi~~~ation ? J. Charles Lee: Interim Director? The Texas A&M University System ? C...~J1ege Station, Texas :,. .,: (Blank Page in OrigiBal BuBetiol ' 1iJ. ~ ; :; . : . . / I Estimated Costs and Returns for Catfish Farms with Recirculating Ponds Along the Upper Texas Coast J.A.D. Lambregts, Marketing Manager for Niaid...

Lambregts, J.A.D.; Griffin, W.L.; Lacewell R.D.; Davis, J.T.; Clary, G.M.

1992-01-01T23:59:59.000Z

151

Gradient zone-boundary control in salt-gradient solar ponds  

DOE Patents [OSTI]

A method and apparatus for suppressing zone boundary migration in a salt gradient solar pond includes extending perforated membranes across the pond at the boundaries, between the convective and non-convective zones, the perforations being small enough in size to prevent individual turbulence disturbances from penetrating the hole, but being large enough to allow easy molecular diffusion of salt thereby preventing the formation of convective zones in the gradient layer. The total area of the perforations is a sizeable fraction of the membrane area to allow sufficient salt diffusion while preventing turbulent entrainment into the gradient zone.

Hull, J.R.

1982-09-29T23:59:59.000Z

152

The effects of cattle on shoreline vegetation of ponds and tanks in south Texas  

E-Print Network [OSTI]

OF SCIENCE December I97S Hajor Subject: Wildlife and. Fisheries Sciences THE EFFECTS OF CATTLE ON SHORELINE VEGETATION OF PONDS AND TANKS IN SOUTH TEXAS A Thesis by RICHARD JOHN WHITE Approved as to content and style by: Chairmen of Committee Head... of Department M ber ber December 1978 ABSTRACT Ti e Effe ts of Cattle on Shoreline Vegetation of Ponds a", !d Tanks in "outh Texas. (December i978) Richard John Nhytc, B, Nat ~ Res. , University of New England Chairman of Mvisory Committee: Dr. N ~ J...

Whyte, Richard John

1978-01-01T23:59:59.000Z

153

Development of a Direct Evaporator for the Organic Rankine Cycle  

SciTech Connect (OSTI)

This paper describes research and development currently underway to place the evaporator of an Organic Rankine Cycle (ORC) system directly in the path of a hot exhaust stream produced by a gas turbine engine. The main goal of this research effort is to improve cycle efficiency and cost by eliminating the usual secondary heat transfer loop. The projects technical objective is to eliminate the pumps, heat exchangers and all other added cost and complexity of the secondary loop by developing an evaporator that resides in the waste heat stream, yet virtually eliminates the risk of a working fluid leakage into the gaseous exhaust stream. The research team comprised of Idaho National Laboratory and General Electric Company engineers leverages previous research in advanced ORC technology to develop a new direct evaporator design that will reduce the ORC system cost by up to 15%, enabling the rapid adoption of ORCs for waste heat recovery.

Donna Post Guillen; Helge Klockow; Matthew Lehar; Sebastian Freund; Jennifer Jackson

2011-02-01T23:59:59.000Z

154

Evaporation rate of hot Jupiters and formation of Chthonian planets  

E-Print Network [OSTI]

Among the hundred of known extrasolar planets, about 15% are closer than 0.1 AU from their parent stars. But there are extremely few detections of planets orbiting in less than 3 days. At this limit the planet HD209458b has been found to have an extended upper atmosphere of escaping hydrogen. This suggests that the so-called hot Jupiters which are close to their parent stars could evaporate. Here we estimate the evaporation rate of hydrogen from extrasolar planets in the star vicinity. With high exospheric temperatures, and owing to the tidal forces, planets evaporate through a geometrical blow-off. This may explain the absence of Jupiter mass planets below a critical distance from the stars. Below this critical distance, we infer the existence of a new class of planets made of the residual central core of former hot Jupiters, which we propose to call the ``Chthonian'' planets.

G. Hbrard; A. Lecavelier des tangs; A. Vidal-Madjar; J. -M. Dsert; R. Ferlet

2003-12-15T23:59:59.000Z

155

Electron beam evaporation for titanium metal matrix composites  

SciTech Connect (OSTI)

3M, in partnership with ARPA, is developing electron beam evaporation as a method for producing titanium metal matrix composites (TMC`s). This paper discusses some of the opportunities presented by these strong and lightweight structural materials but also points out the many challenges which must be met. The excellent mechanical properties of titanium matrix composites have been recognized for quite some time; however use of these materials has been limited by the lack of a commercially viable process to produce them. 3M is removing this logjam in processing technology by using high rate electron beam evaporation technology to manufacture these materials on a significantly large scale.

Storer, J. [3M, Mendota Heights, MN (United States)

1994-12-31T23:59:59.000Z

156

Simulation of Diffusive Lithium Evaporation Onto the NSTX Vessel Walls  

SciTech Connect (OSTI)

A model for simulating the diffusive evaporation of lithium into a helium filled NSTX vacuum vessel is described and validated against an initial set of deposition experiments. The DEGAS 2 based model consists of a three-dimensional representation of the vacuum vessel, the elastic scattering process, and a kinetic description of the evaporated atoms. Additional assumptions are required to account for deuterium out-gassing during the validation experiments. The model agrees with the data over a range of pressures to within the estimated uncertainties. Suggestions are made for more discriminating experiments that will lead to an improved model.

Stotler, D. P.; Skinner, C. H.; Blanchard, W. R.; Krstic, P. S.; Kugel, H. W.; Schneider, H.; Zakharov, L. E.

2010-12-09T23:59:59.000Z

157

2010 Radiological Monitoring Results Associated with the Advance Test Reactor Complex Cold Waste Pond  

SciTech Connect (OSTI)

This report summarizes radiological monitoring performed of the Idaho National Laboratory Sites Advanced Test Reactor Complex Cold Waste wastewater prior to discharge into the Cold Waste Pond and of specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit (#LA-000161-01, Modification B). All radiological monitoring is performed to fulfill Department of Energy requirements under the Atomic Energy Act.

mike lewis

2011-02-01T23:59:59.000Z

158

2013 Radiological Monitoring Results Associated with the Advanced Test Reactor Complex Cold Waste Pond  

SciTech Connect (OSTI)

This report summarizes radiological monitoring performed of the Idaho National Laboratory Sites Advanced Test Reactor Complex Cold Waste wastewater prior to discharge into the Cold Waste Pond and of specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit (#LA-000161-01, Modification B). All radiological monitoring is performed to fulfill Department of Energy requirements under the Atomic Energy Act.

Mike Lewis

2014-02-01T23:59:59.000Z

159

Ponding Test Results Seepage and Total Losses Main Canal B Hidalgo County Irrigation District No. 16  

E-Print Network [OSTI]

TR-325 2008 Ponding Test Results Seepage and Total Losses Main Canal B Hidalgo County Irrigation District No. 16 Eric Leigh Texas AgriLife Extension Associate, Biological and Agricultural Engineering... MAIN CANAL B HIDALGO COUNTY IRRIGATION DISTRICT NO. 16 Report Prepared by: Eric Leigh and Guy Fipps,1 P.E. February 17, 2004 IRRIGATION TECHNOLOGY CENTER Texas Cooperative Extension - Texas Agricultural...

Leigh, E.; Fipps, G.

160

2012 Radiological Monitoring Results Associated with the Advanced Test Reactor Complex Cold Waste Pond  

SciTech Connect (OSTI)

This report summarizes radiological monitoring performed of the Idaho National Laboratory Sites Advanced Test Reactor Complex Cold Waste wastewater prior to discharge into the Cold Waste Pond and of specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit (#LA-000161-01, Modification B). All radiological monitoring is performed to fulfill Department of Energy requirements under the Atomic Energy Act.

Mike Lewis

2013-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "lined evaporation pond" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Reconstruction and operation of the El Paso Solar Pond with a geosynthetic clay liner system  

SciTech Connect (OSTI)

After the original XR-5 membrane liner failed in 1992, the El Paso Solar Pond was reconstructed and operated with a geosynthetic clay liner (GCL) system. The solar pond is approximately 3,000 m{sup 2} in surface area, and 3.2 meters deep with a 15{degree} side-wall slope. A new heat extraction system includes 15-cm (6-inch) rubber hoses and two redesigned polypropylene diffusers. A new automated instrumentation system was developed for monitoring pond status. It uses a newly developed scanner combined with a computer for both position control and data logging. The salinity gradient was established using a new scanning method, as opposed to the previously used fixed point method. Fresh water was injected into brine through a newly designed PVC bar shaped diffuser, which scans automatically within preset regions. After two months, the pond bottom reached 80 C and heat extraction began. The performance of the GCL system, characterized by its hydraulic conductivity, has been monitored, and generates the first full scale, elevated temperature data for a GCL system. Preliminary hydraulic conductivity data indicate values comparable with other clay liner systems.

Lu, H.; Swift, A.H.P. [Univ. of Texas, El Paso, TX (United States)

1996-12-31T23:59:59.000Z

162

Pond thermal stratification and turnover -A 1 Year Experiment Last updated on 9 Dec 2008  

E-Print Network [OSTI]

. We recorded the temperatures once every 50 sec continuously. The voltage output of a solar cell is also recorded. The solar cell shows sunrise and sunset and the passing of clouds. The pond is located temperature vs. time will be updated from time to time as more data is collected. If you have comments

Suzuki, Masatsugu

163

Sampling and Hydrogeology of the Vadose Zone Beneath the 300 Area Process Ponds  

SciTech Connect (OSTI)

Four open pits were dug with a backhoe into the vadose zone beneath the former 300 Area Process Ponds in April 2003. Samples were collected about every 2 feet for physical, chemical, and/or microbiological characterization. This reports presents a stratigraphic and geohydrologic summary of the four excavations.

Bjornstad, Bruce N.

2004-08-31T23:59:59.000Z

164

Fishing is an important use of private ponds throughout Pennsylvania. In fact, a recent survey  

E-Print Network [OSTI]

largemouth bass and sunfish, prefer water temperatures above 80F in the summer while cold-water fish, like are cool-water fish, like smallmouth bass, that are adapted to both conditions. Proper stocking-water fish like largemouth bass (Figure 1) and bluegill. This combination is generally successful in ponds

Boyer, Elizabeth W.

165

Tracing anthropogenic nutrient inputs to coastal plain ponds using stable Wayne Daniel1  

E-Print Network [OSTI]

is to determine if invasive species Phragmites australis is dependent on sewage derived nitrogen using stable tissues in Duck Pond expressed elevated del 15 N values. Del 15 N of and Phragmites australis suggested colonization. Phragmites australis is know in North America as the common reed, but has a genetic lineage

Vallino, Joseph J.

166

Western Pond Turtle Head-starting and Reintroduction; 2003-2004 Annual Report.  

SciTech Connect (OSTI)

This report covers the results of the western pond turtle head-starting and reintroduction project for the period of October 2003-September 2004. Wild hatchling western pond turtles from the Columbia River Gorge were reared at the Woodland Park and Oregon Zoos in 2003 and 2004 as part of the recovery effort for this Washington State endangered species. The objective of the program is to reduce losses to introduced predators like bullfrogs and largemouth bass by raising the hatchlings to a size where they are too large to be eaten by most of these predators. Sixty-nine turtles were over-wintered at the Woodland Park Zoo and 69 at the Oregon Zoo. Of these, 136 head-started juvenile turtles were released at three sites in the Columbia Gorge in 2004. Two were held back to attain more growth in captivity. Thirty-four were released at the Klickitat ponds, 19 at the Klickitat lake, 21 at the Skamania site, and 62 at Pierce National Wildlife Refuge (NWR). This brought the total number of head-start turtles released since 1991 to 246 for the Klickitat ponds, 114 for the Klickitat lake, 167 for the Skamania pond complex, and 250 at Pierce NWR. In 2004, 32 females from the two Columbia Gorge populations were equipped with transmitters and monitored for nesting activity. Twenty-one of the females nested and produced 85 hatchlings. The hatchlings were collected in September and October and transported to the Woodland Park and Oregon zoos for rearing in the head-start program. Data collection for a four-year telemetry study of survival and habitat use by juvenile western pond turtles at Pierce NWR concluded in 2004. Radio transmitters on study animals were replaced as needed until all replacements were in service; afterward, the turtles were monitored until their transmitters failed. The corps of study turtles ranged from 39 in August 2003 to 2 turtles at the end of August 2004. These turtles showed the same seasonal pattern of movements between summer water and upland winter habitats observed in previous years. During the 2004 field season trapping effort, 345 western pond turtles were captured in the Columbia Gorge, including 297 previously head-started turtles. These recaptures, together with confirmed nesting by head-start females and visual resightings, indicate the program is succeeding in boosting juvenile recruitment to increase the populations. Records were also collected on 224 individual painted turtles captured in 2004 during trapping efforts at Pierce NWR, to gather baseline information on this native population. Bonneville Power Administration (BPA) funded approximately 60% of program activities in the Columbia River Gorge from October 2003 through September 2004.

Van Leuven, Susan; Allen, Harriet; Slavin, Kate (Washington Department of Fish and Wildlife, Wildlife Management Program, Olympia, WA)

2004-09-01T23:59:59.000Z

167

242-A Evaporator Waste Analysis Plan. Revision 5  

SciTech Connect (OSTI)

This Waste Analysis Plan (WAP) provides the plan for obtaining information needed for proper waste handling and processing in the 242-A Evaporator (Evaporator) located on the Hanford Site. In particular it addresses analysis necessary to manage the waste according to Washington Administrative Code (WAC) 173-303 and Parts 264 and 265 of the Code of Federal Regulations (CFR). Regulatory and safety issues are addressed by establishing boundary conditions for waste received and treated at the 242-A Evaporator. The boundary conditions are set by establishing limits for items such as potential exothermic reactions, waste compatibility, and control of vessel vent organic emissions. Boundary conditions are also set for operational considerations and to ensure waste acceptance at receiving facilities. The issues that are addressed in this plan include prevention of exotherms in the waste, waste compatibility, and vessel vent emissions. Samples from the other streams associated with the Evaporator are taken as required by Process Control Plans but are excluded from this plan because either the streams do not contain dangerous waste or the analyses are not required by WAC 173-303-300.

Basra, T.S.

1995-04-13T23:59:59.000Z

168

Nanotube Boiler 1 Abstract--Controlled copper evaporation at attogram  

E-Print Network [OSTI]

Nanotube Boiler 1 Abstract-- Controlled copper evaporation at attogram level from individual carbon nanotube (CNT) vessels, which we call nanotube boilers, is investigated experimentally, and ionization in these CNT boilers, which can serve as sources for mass transport and deposition in nanofluidic

Paris-Sud XI, Université de

169

11Chandra 'Sees' a Distant Planet Evaporating NASA's Chandra Observatory  

E-Print Network [OSTI]

energy. A simple model of this planet's interior suggests that its atmosphere might account for as much11Chandra 'Sees' a Distant Planet Evaporating NASA's Chandra Observatory has discovered that the star CoRot-2a is a powerful X-ray source. This is unfortunate because it is also known that a planet

170

Hanford high-level waste evaporator/crystallizer corrosion evaluation  

SciTech Connect (OSTI)

The US Department of Energy, Hanford Site nuclear reservation, located in Southeastern Washington State, is currently home to 61 Mgal of radioactive waste stored in 177 large underground storage tanks. As an intermediate waste volume reduction, the 242-A Evaporator/Crystallizer processes waste solutions from most of the operating laboratories and plants on the Hanford Site. The waste solutions are concentrated in the Evaporator/Crystallizer to a slurry of liquid and crystallized salts. This concentrated slurry is returned to Hanford Site waste tanks at a significantly reduced volume. The Washington State Department of Ecology Dangerous Waste Regulations, WAC 173-393 require that a tank system integrity assessment be completed and maintained on file at the facility for all dangerous waste tank systems. This corrosion evaluation was performed in support of the 242-A Evaporator/Crystallizer Tank System Integrity Assessment Report. This corrosion evaluation provided a comprehensive compatibility study of the component materials and corrosive environments. Materials used for the Evaporator components and piping include austenitic stainless steels (SS) (primarily ASTM A240, Type 304L) and low alloy carbon steels (CS) (primarily ASTM A53 and A106) with polymeric or asbestos gaskets at flanged connections. Building structure and secondary containment is made from ACI 301-72 Structural Concrete for Buildings and coated with a chemically resistant acrylic coating system.

Ohl, P.C.; Carlos, W.C.

1993-10-01T23:59:59.000Z

171

Calculation of Reactive-evaporation Rates of Chromia  

SciTech Connect (OSTI)

A methodology is developed to calculate Cr-evaporation rates from Cr2O3 with a flat planar geometry. Variables include temperature, total pressure, gas velocity, and gas composition. The methodology was applied to solid-oxide, fuel cell conditions for metallic interconnects and to advanced-steam turbines conditions. The high velocities and pressures of the advanced steam turbine led to evaporation predictions as high as 5.18 9 10-8 kg/m2/s of CrO2(OH)2(g) at 760 C and 34.5 MPa. This is equivalent to 0.080 mm per year of solid Cr loss. Chromium evaporation is expected to be an important oxidation mechanism with the types of nickel-base alloys proposed for use above 650 C in advanced-steam boilers and turbines. It is shown that laboratory experiments, with much lower steam velocities and usually much lower total pressure than found in advanced steam turbines, would best reproduce chromium-evaporation behavior with atmospheres that approach either O2 + H2O or air + H2O with 57% H2O.

Holcomb, G.R.

2008-04-01T23:59:59.000Z

172

Western Pond Turtle Head-starting and Reintroduction, 2005-2006 Annual Report.  

SciTech Connect (OSTI)

This report covers the results of the western pond turtle head-starting and reintroduction project for the period of October 2005-September 2006. Wild hatchling western pond turtles from the Columbia River Gorge were reared at the Woodland Park and Oregon zoos in 2005 and 2006 as part of the recovery effort for this Washington State endangered species. The objective of the program is to reduce losses to introduced predators like bullfrogs and largemouth bass by raising the hatchlings to a size where they are too large to be eaten by most of these predators. Twenty-six turtles were placed at the Woodland Park Zoo and 62 at the Oregon Zoo in fall 2005. These turtles joined two that were held back from release in summer 2005 due to their small size. All 90 juvenile turtles were released at three sites in the Columbia Gorge in 2006. Twenty-eight juvenile turtles were released at the Klickitat ponds, 22 at the Klickitat lake, 21 at the Skamania site, and 19 at Pierce National Wildlife Refuge (NWR). This brought the total number of head-start turtles released since 1991 to 944; 285 for the Klickitat ponds, 158 for the Klickitat lake, 227 for the Skamania pond complex, and 274 at Pierce NWR. In 2006, 20 females from the Klickitat population were equipped with transmitters and monitored for nesting activity. Fifteen nests were located and protected; these produced 55 hatchlings. The hatchlings were collected in September and transported to the Oregon and Woodland Park zoos for rearing in the head-start program. One wild hatchling captured in spring 2006 was placed in the head-start program to attain more growth in captivity. During the 2006 field season trapping effort, 414 western pond turtles were captured in the Columbia Gorge, including 374 previously head-started turtles. These recaptures, together with confirmed nesting by head-start females and visual resightings, indicate the program is succeeding in boosting juvenile recruitment to increase the populations. Records were also collected on 179 individual painted turtles captured in 2006 during trapping efforts at Pierce NWR, to gather baseline information on this native population.

Van Leuven, Susan; Allen, Harriet; Slavens, Kate (Washington Department of Fish and Wildlife, Wildlife Management Program, Olympia, WA)

2006-11-01T23:59:59.000Z

173

Western Pond Turtle Head-starting and Reintroduction; 2004-2005 Annual Report.  

SciTech Connect (OSTI)

This report covers the results of the western pond turtle head-starting and reintroduction project for the period of October 2004-September 2005. Wild hatchling western pond turtles from the Columbia River Gorge were reared at the Woodland Park and Oregon Zoos in 2004 and 2005 as part of the recovery effort for this Washington State endangered species. The objective of the program is to reduce losses to introduced predators like bullfrogs and largemouth bass by raising the hatchlings to a size where they are too large to be eaten by most of these predators. Thirty-five turtles were placed at the Woodland Park Zoo and 53 at the Oregon Zoo. Of these, 77 head-started juvenile turtles were released at three sites in the Columbia Gorge in 2005. Four were held back to attain more growth in captivity. Eleven were released at the Klickitat ponds, 22 at the Klickitat lake, 39 at the Skamania site, and 5 at Pierce National Wildlife Refuge (NWR). This brought the total number of head-start turtles released since 1991 to 257 for the Klickitat ponds, 136 for the Klickitat lake, 206 for the Skamania pond complex, and 255 at Pierce NWR. In 2005, 34 females from the two Columbia Gorge populations were equipped with transmitters and monitored for nesting activity. Twenty-four nests were located and protected; these produced 90 hatchlings. The hatchlings were collected in September and transported to the Oregon and Woodland Park zoos for rearing in the head-start program. During the 2005 field season trapping effort, 486 western pond turtles were captured in the Columbia Gorge, including 430 previously head-started turtles. These recaptures, together with confirmed nesting by head-start females and visual resightings, indicate the program is succeeding in boosting juvenile recruitment to increase the populations. Records were also collected on 216 individual painted turtles captured in 2005 during trapping efforts at Pierce NWR, to gather baseline information on this native population. Bonneville Power Administration (BPA) funded approximately 75% of program activities in the Columbia River Gorge from October 2004 through September 2005.

Van Leuven, Susan; Allen, Harriet; Slavin, Kate (Washington Department of Fish and Wildlife, Wildlife Management Program, Olympia, WA)

2005-09-01T23:59:59.000Z

174

Calculation notes that support accident scenario and consequence of the evaporator dump  

SciTech Connect (OSTI)

The purpose of this calculation note is to provide the basis for evaporator dump consequence for the Tank Farm Safety Analysis Report (FSAR). Evaporator Dump scenario is developed and details and description of the analysis methods are provided.

Crowe, R.D., Westinghouse Hanford

1996-09-09T23:59:59.000Z

175

Calculation notes that support accident scenario and consequence of the evaporator dump  

SciTech Connect (OSTI)

The purpose of this calculation note is to provide the basis for evaporator dump consequence for the Tank Farm Safety Analysis Report (FSAR). Evaporator Dump scenario is developed and details and description of the analysis methods are provided.

Crowe, R.D.

1996-09-27T23:59:59.000Z

176

The Savannah River Site Replacement High Level Radioactive Waste Evaporator Project  

SciTech Connect (OSTI)

The Replacement High Level Waste Evaporator Project was conceived in 1985 to reduce the volume of the high level radioactive waste Process of the high level waste has been accomplished up to this time using Bent Tube type evaporators and therefore, that type evaporator was selected for this project. The Title I Design of the project was 70% completed in late 1990. The Department of Energy at that time hired an independent consulting firm to perform a complete review of the project. The DOE placed a STOP ORDER on purchasing the evaporator in January 1991. Essentially, no construction was to be done on this project until all findings and concerns dealing with the type and design of the evaporator are resolved. This report addresses two aspects of the DOE design review; (1) Comparing the Bent Tube Evaporator with the Forced Circulation Evaporator, (2) The design portion of the DOE Project Review - concentrated on the mechanical design properties of the evaporator. 1 ref.

Presgrove, S.B. (Bechtel Savannah River, Inc., North Augusta, SC (United States))

1992-01-01T23:59:59.000Z

177

The Savannah River Site Replacement High Level Radioactive Waste Evaporator Project  

SciTech Connect (OSTI)

The Replacement High Level Waste Evaporator Project was conceived in 1985 to reduce the volume of the high level radioactive waste Process of the high level waste has been accomplished up to this time using Bent Tube type evaporators and therefore, that type evaporator was selected for this project. The Title I Design of the project was 70% completed in late 1990. The Department of Energy at that time hired an independent consulting firm to perform a complete review of the project. The DOE placed a STOP ORDER on purchasing the evaporator in January 1991. Essentially, no construction was to be done on this project until all findings and concerns dealing with the type and design of the evaporator are resolved. This report addresses two aspects of the DOE design review; (1) Comparing the Bent Tube Evaporator with the Forced Circulation Evaporator, (2) The design portion of the DOE Project Review - concentrated on the mechanical design properties of the evaporator. 1 ref.

Presgrove, S.B. [Bechtel Savannah River, Inc., North Augusta, SC (United States)

1992-08-01T23:59:59.000Z

178

Experimental Simulation of Evaporation-Driven Silica Sinter Formation and Microbial Silicification in Hot Spring Systems  

E-Print Network [OSTI]

in geothermal waters after they have reached the surface. Water evaporation is, along with cooling, one Evaporation of silica-rich geothermal waters is one of the main abiotic drivers of the formation of silica

Paris-Sud XI, Université de

179

ANALYSIS OF 2H-EVAPORATOR SCALE WALL [HTF-13-82] AND POT BOTTOM [HTF-13-77] SAMPLES  

SciTech Connect (OSTI)

Savannah River Remediation (SRR) is planning to remove a buildup of sodium aluminosilicate scale from the 2H-evaporator pot by loading and soaking the pot with heated 1.5 M nitric acid solution. Sampling and analysis of the scale material has been performed so that uranium and plutonium isotopic analysis can be input into a Nuclear Criticality Safety Assessment (NCSA) for scale removal by chemical cleaning. Historically, since the operation of the Defense Waste Processing Facility (DWPF), silicon in the DWPF recycle stream combines with aluminum in the typical tank farm supernate to form sodium aluminosilicate scale mineral deposits in the 2Hevaporator pot and gravity drain line. The 2H-evaporator scale samples analyzed by Savannah River National Laboratory (SRNL) came from the bottom cone sections of the 2H-evaporator pot [Sample HTF-13-77] and the wall 2H-evaporator [sample HTF-13-82]. X-ray diffraction analysis (XRD) confirmed that both the 2H-evaporator pot scale and the wall samples consist of nitrated cancrinite (a crystalline sodium aluminosilicate solid) and clarkeite (a uranium oxy-hydroxide mineral). On as received basis, the bottom pot section scale sample contained an average of 2.59E+00 1.40E-01 wt % total uranium with a U-235 enrichment of 6.12E-01 1.48E-02 %, while the wall sample contained an average of 4.03E+00 9.79E-01 wt % total uranium with a U-235 enrichment of 6.03E-01% 1.66E-02 wt %. The bottom pot section scale sample analyses results for Pu-238, Pu-239, and Pu-241 are 3.16E- 05 5.40E-06 wt %, 3.28E-04 1.45E-05 wt %, and <8.80E-07 wt %, respectively. The evaporator wall scale samples analysis values for Pu-238, Pu-239, and Pu-241 averages 3.74E-05 6.01E-06 wt %, 4.38E-04 5.08E-05 wt %, and <1.38E-06 wt %, respectively. The Pu-241 analyses results, as presented, are upper limit values. These results are provided so that SRR can calculate the equivalent uranium-235 concentrations for the NCSA. Results confirm that the uranium contained in the scale remains depleted with respect to natural uranium. SRNL did not calculate an equivalent U-235 enrichment, which takes into account other fissionable isotopes U-233, Pu-239 and Pu-241. The applicable method for calculation of equivalent U-235 will be determined in the NCSA.

Oji, L.

2013-06-21T23:59:59.000Z

180

Detailed modeling of the evaporation and thermal decomposition of urea-water-solution in SCR systems  

E-Print Network [OSTI]

on the UWS evaporation is taken into account using a NRTL activity model. The thermal decomposition model

Boyer, Edmond

Note: This page contains sample records for the topic "lined evaporation pond" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Inkjet fabrication of polymer microarrays and grids-solving the evaporation problem  

E-Print Network [OSTI]

allowing the rapid generation of a broad range of co-polymers, while solving the problem of selective monomer evaporation....

Bradley M.; Zhang R.; Liberski A.

2009-01-01T23:59:59.000Z

182

The redox and iron-sulfide geochemistry of Salt Pond and the thermodynamic constraints on native magnetotactic bacteria  

E-Print Network [OSTI]

Salt pond is a meromictic system with an outlet to the sea allowing denser seawater to occupy the monimolimnion while the mixolimnion has relatively low salinity and is the site of greater mixing and microbial activity. ...

Canovas, Peter A

2006-01-01T23:59:59.000Z

183

Converting Simulated Sodium-bearing Waste into a Single Solid Waste Form by Evaporation: Laboratory- and Pilot-Scale Test Results on Recycling Evaporator Overheads  

SciTech Connect (OSTI)

Conversion of Idaho National Engineering and Environmental Laboratory radioactive sodium-bearing waste into a single solid waste form by evaporation was demonstrated in both flask-scale and pilot-scale agitated thin film evaporator tests. A sodium-bearing waste simulant was adjusted to represent an evaporator feed in which the acid from the distillate is concentrated, neutralized, and recycled back through the evaporator. The advantage to this flowsheet is that a single remote-handled transuranic waste form is produced in the evaporator bottoms without the generation of any low-level mixed secondary waste. However, use of a recycle flowsheet in sodium-bearing waste evaporation results in a 50% increase in remote-handled transuranic volume in comparison to a non-recycle flowsheet.

Griffith, D.; D. L. Griffith; R. J. Kirkham; L. G. Olson; S. J. Losinski

2004-01-01T23:59:59.000Z

184

Energy conservation in black-liquor evaporator of pulp and paper industry  

SciTech Connect (OSTI)

This paper is an attempt on energy conservation in a quintuple effect evaporator used to concentrate dilute black liquor solution by raising their steam economy through the changes in the operating variables. It also describes the steam economy of the evaporator for the various feed arrangements so as to determine the ranges of the variables for which evaporation occurs profitable.

Agarwal, V.K.; Gupta, S.C. [Univ. of Roorkee (India). Dept. of Chemical Engineering

1995-12-31T23:59:59.000Z

185

Evaporation and Condensation of Large Droplets in the Presence of Inert Admixtures Containing Soluble Gas  

E-Print Network [OSTI]

the mutual influence of heat and mass transfer during gas absorption and evaporation or condensation transfer during gas absorption by liquid droplets and during droplets evaporation and va- por condensationEvaporation and Condensation of Large Droplets in the Presence of Inert Admixtures Containing

Elperin, Tov

186

Evaluation of the Eological Management and Enhancement Alernative for Remediation of the K1007-P1 Pond  

SciTech Connect (OSTI)

An evaluation of the human and ecological risks associated with the P1 Pond and surrounding environs was conducted as part of the ETTP Site-Wide Remedial Investigation. The RI provides the basis for the focus on PCBs as the most important unacceptable risk to human and ecological health in the pond. Other P1 contaminants, media, or pathways of risk to receptors are identified in the RI, but are not addressed as a major risk reduction goal for the ETTP Site-Wide Feasibility Study. Therefore, the goal of the Ecological Management alternative is to reduce unacceptable risks associated with PCBs in fish. Many of the actions proposed for this alternative, however, are likely to reduce risks associated with other contaminants and their pathways. The high PCB concentrations in fish from the P1 Pond are most certainly due in part to the current ecological condition of the pond that maximizes PCB biomagnification. This basic assumption and the factors contributing to it were evaluated by conducting an intensive field study of the P1 Pond in the summer of 2004 (for a thorough presentation of current P1 Pond biological conditions, see Peterson et al. 2005). Major hypotheses regarding the P1 Pond's current fish community, PCB fate and transport processes, pond vegetation, and limnological conditions that contribute to the high PCB levels in fish were validated by the study (Appendix A), The results of the 2004 ecological assessment, in concert with long-term datasets obtained as part of the ETTP Biological Monitoring and Abatement Program (BMAP) and recent abiotic sampling for the RI, provide the basis for the assessment of current conditions.

Peterson, M.J.

2005-10-31T23:59:59.000Z

187

Pond Creek coal seam in eastern Kentucky - new look at an old resource  

SciTech Connect (OSTI)

The Middle Pennsylvania/Westphalian B Pond Creek Coal is an important low-sulfur resource in Pike and Martin Counties, Kentucky. The Breathitt Formation seam, also known as the lower Elkhorn coal, accounted for nearly 40% of Pike County's 1983 production of 22 million tons. Although the coal is nearly mined out through central Pike County, substantial reserves still exist in the northern part of the county. Past studies of the seam by the US Bureau of Mines concentrated on the utility of the seam as a coking blend, with additional consideration of the megascopic and microscopic coal petrology. The authors research has focused on the regional variations in the Pond Creek seam, with emphasis on the petrographic variations.

Hower, J.C.; Pollock, J.D.; Klapheke, J.G.

1986-05-01T23:59:59.000Z

188

CHROMOSPHERIC EVAPORATION IN AN M1.8 FLARE OBSERVED BY THE EXTREME-ULTRAVIOLET IMAGING SPECTROMETER ON HINODE  

SciTech Connect (OSTI)

We discuss observations of chromospheric evaporation for a complex flare that occurred on 2012 March 9 near 03:30 UT obtained from the Extreme-ultraviolet Imaging Spectrometer (EIS) on board the Hinode spacecraft. This was a multiple event with a strong energy input that reached the M1.8 class when observed by EIS. EIS was in raster mode and fortunately the slit was almost at the exact location of a significant energy input. Also, EIS obtained a full-CCD spectrum of the flare, i.e., the entire CCD was readout so that data were obtained for about the 500 lines identified in the EIS wavelength ranges. Chromospheric evaporation characterized by 150-200 km s{sup -1} upflows was observed in multiple locations in multi-million degree spectral lines of flare ions such as Fe XXII, Fe XXIII, and Fe XXIV, with simultaneous 20-60 km s{sup -1} upflows in million degree coronal lines from ions such as Fe XII-Fe XVI. The behavior of cooler, transition region ions such as O VI, Fe VIII, He II, and Fe X is more complex, but upflows were also observed in Fe VIII and Fe X lines. At a point close to strong energy input in space and time, the flare ions Fe XXII, Fe XXIII, and Fe XXIV reveal an isothermal source with a temperature close to 14 MK and no strong blueshifted components. At this location there is a strong downflow in cooler active region lines from ions such as Fe XIII and Fe XIV, on the order of 200 km s{sup -1}. We speculate that this downflow may be evidence of the downward shock produced by reconnection in the current sheet seen in MHD simulations. A sunquake also occurred near this location. Electron densities were obtained from density sensitive lines ratios from Fe XIII and Fe XIV. Atmospheric Imaging Assembly (AIA) observations from the Solar Dynamics Observatory are used with JHelioviewer to obtain a qualitative overview of the flare. However, AIA data are not presented in this paper. In summary, spectroscopic data from EIS are presented that can be used for predictive tests of models of chromospheric evaporation as envisaged in the Standard Flare Model.

Doschek, G. A.; Warren, H. P. [Space Science Division, Naval Research Laboratory, Washington, DC 20375 (United States)] [Space Science Division, Naval Research Laboratory, Washington, DC 20375 (United States); Young, P. R. [College of Science, George Mason University, 4400 University Drive, Fairfax, VA 22030 (United States)] [College of Science, George Mason University, 4400 University Drive, Fairfax, VA 22030 (United States)

2013-04-10T23:59:59.000Z

189

Axially Tapered And Bilayer Microchannels For Evaporative Cooling Devices  

DOE Patents [OSTI]

The invention consists of an evaporative cooling device comprising one or more microchannels whose cross section is axially reduced to control the maximum capillary pressure differential between liquid and vapor phases. In one embodiment, the evaporation channels have a rectangular cross section that is reduced in width along a flow path. In another embodiment, channels of fixed width are patterned with an array of microfabricated post-like features such that the feature size and spacing are gradually reduced along the flow path. Other embodiments incorporate bilayer channels consisting of an upper cover plate having a pattern of slots or holes of axially decreasing size and a lower fluid flow layer having channel widths substantially greater than the characteristic microscale dimensions of the patterned cover plate. The small dimensions of the cover plate holes afford large capillary pressure differentials while the larger dimensions of the lower region reduce viscous flow resistance.

Nilson, Robert (Cardiff, CA); Griffiths, Stewart (Livermore, CA)

2005-10-04T23:59:59.000Z

190

Evaporation-based Ge/.sup.68 Ga Separation  

DOE Patents [OSTI]

Micro concentrations of .sup.68 Ga in secular equilibrium with .sup.68 Ge in strong aqueous HCl solution may readily be separated in ionic form from the .sup.68 Ge for biomedical use by evaporating the solution to dryness and then leaching the .sup.68 Ga from the container walls with dilute aqueous solutions of HCl or NaCl. The chloro-germanide produced during the evaporation may be quantitatively recovered to be used again as a source of .sup.68 Ga. If the solution is distilled to remove any oxidizing agents which may be present as impurities, the separation factor may easily exceed 10.sup.5. The separation is easily completed and the .sup.68 Ga made available in ionic form in 30 minutes or less.

Mirzadeh, Saed (Albuquerque, NM); Whipple, Richard E. (Los Alamos, NM); Grant, Patrick M. (Los Alamos, NM); O'Brien, Jr., Harold A. (Los Alamos, NM)

1981-01-01T23:59:59.000Z

191

Evaluation of models for predicting evaporative water loss in cooling impoundments  

E-Print Network [OSTI]

Cooling impoundments can offer a number of advantages over cooling towers for condenser water cooling at steam electric power plants. However, a major disadvantage of cooling ponds is a lack of confidence in the ability ...

Helfrich, Karl Richard

1982-01-01T23:59:59.000Z

192

K-Area and Par Pond Sewage Sludge Application Sites groundwater monitoring report, Third quarter 1992  

SciTech Connect (OSTI)

During third quarter 1992, the three wells at the K-Area Sewage Sludge Application Site (KSS wells) and the three wells at the Par Pond Sewage Sludge Application Site (PSS wells) were sampled for analyses required each quarter or annually by South Carolina Department of Health and Environmental Control Construction Permit 13,173 and for base-neutral/acid semivolatile constituents. None of the analytical results exceeded standards.

Thompson, C.Y.

1993-01-01T23:59:59.000Z

193

Don Juan Pond, Antarctica: Near-surface CaCl2-brine feeding Earth's most saline  

E-Print Network [OSTI]

Don Juan Pond, Antarctica: Near-surface CaCl2-brine feeding Earth's most saline lake for RSL formation, CaCl2 brines and chloride deposits in basins may provide clues to the origin of ancient,2,10­14 , the composition of the brine is unlike any other body of water in the world, as ,90% of the salt is CaCl2 1

Marchant, David R.

194

Waterfowl use of sediment ponds on an east Texas coal mine  

E-Print Network [OSTI]

appreciation. Lastly, I thank my wife, Diana, who makes my life a continual adventure. She provided the love, encouragement, and confidence I often needed during my graduate work. vii TABLE OF CONTENTS Page ABSTRACT. ACKNOWLEDGEMENT. TABLE OF CONTENTS... Brown Mine by waterfowl use in Year 1. 2 Measurements of vegetative cover (m and k), shallow water, light transmission (cm), slope (k), and vegetative richness for 15 ponds in high, medium, and low waterfowl use classes at Big Brown Mine. 41 42...

Reynolds, Larry A

1989-01-01T23:59:59.000Z

195

State Environmental Policy Act (SEPA) Environmental Checklist Form 216-B-3 Expansion Ponds Closure Plan. Revision 1  

SciTech Connect (OSTI)

The 216-B-3 Expansion Ponds Closure Plan (Revision 1) consists of a Part A Dangerous Waste Permit Application and a Resource Conservation and Recovery Act Closure Plan. An explanation of the Part A submitted with this document is provided at the beginning of the Part A Section. The closure plan consists of nine chapters and five appendices. The 216-B-3 Pond System consists of a series of four earthen, unlined, interconnected ponds and the 216-B-3-3 Ditch that receive waste water from various 200 East Area operating facilities. These four ponds, collectively. Waste water (primarily cooling water, steam condensate, and sanitary water) from various 200 East Area facilities is discharged to the 216-B-3-3 Ditch. Water discharged to the 216-8-3-3 Ditch flows directly into the 216-B-3 Pond. In the past, waste water discharges to B Pond and the 216-B-3-3 Ditch contained mixed waste (radioactive waste and dangerous waste). The radioactive portion of mixed waste has been interpreted by the US Department of Energy (DOE) to be regulated under the Atomic Energy Act of 1954; the nonradioactive dangerous portion of mixed waste is regulated under RCRA. Mixed waste also may be considered a hazardous substance under the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) when considering remediation of waste sites.

Not Available

1993-12-01T23:59:59.000Z

196

Techniques for evaluation of e-beam evaporative processes  

SciTech Connect (OSTI)

Efforts to evaluate and characterize electron beam evaporative processes at LLNL have produced a number of techniques and capabilities which have proven useful in advancing the process understanding. One of these diagnostic tools, high dynamic range video imaging of the molten pool surface, has provided insight regarding process responses at the melt pool liquid-vapor interface. A water cooled video camera provides continuous high resolution imaging of the pool surface from a low angle position within 20 cm of the liquid-vapor interface. From this vantage point, the e-beam footprint is clearly defined and melt pool free surface shape can be observed. Effects of changes in e-beam footprint, power distribution and sweep frequency on pool surface shape and stability of vaporization are immediately shown. Other electron beam melting and vaporization events have been observed and recorded. These include: formation of the pool and dissipation of {open_quotes}rafts{close_quotes} on the pool surface during startup, behavior of feed material as it enters the pool, effects of feed configuration changes on the mixing of feed entering the pool volume and behaviors of co-evaporated materials of different vapor pressures at the feed/pool boundary. When used in conjunction with laser vapor monitoring capabilities (presented at the 1994 Electron Beam Melting and Refining Conference, Reno, NV), correlation between pool surface phenomena and vaporizer performance has been identified. This video capability was used in verifying the titanium evaporation model results presented at this conference by confirming the calculated melt pool surface deformations caused by vapor pressure of the departing evaporant at the liquid-vapor interface.

Meier, T.C.; Nelson, C.M. [Lawrence Livermore National Lab., CA (United States)

1996-12-31T23:59:59.000Z

197

The lifetime problem of evaporating black holes: mutiny or resignation  

E-Print Network [OSTI]

It is logically possible that regularly evaporating black holes exist in nature. In fact, the prevalent theoretical view is that these are indeed the real objects behind the curtain in astrophysical scenarios. There are several proposals for regularizing the classical singularity of black holes so that their formation and evaporation do not lead to information-loss problems. One characteristic is shared by most of these proposals: these regularly evaporating black holes present long-lived trapping horizons, with absolutely enormous evaporation lifetimes in whatever measure. Guided by the discomfort with these enormous and thus inaccessible lifetimes, we elaborate here on an alternative regularization of the classical singularity, previously proposed by the authors in an emergent gravity framework, which leads to a completely different scenario. In our scheme the collapse of a stellar object would result in a genuine time-symmetric bounce, which in geometrical terms amounts to the connection of a black-hole geometry with a white-hole geometry in a regular manner. The two most differential characteristics of this proposal are: i) the complete bouncing geometry is a solution of standard classical general relativity everywhere except in a transient region that necessarily extends beyond the gravitational radius associated with the total mass of the collapsing object; and ii) the duration of the bounce as seen by external observers is very brief (fractions of milliseconds for neutron-star-like collapses). This scenario motivates the search for new forms of stellar equilibrium different from black holes. In a brief epilogue we compare our proposal with a similar geometrical setting recently proposed by Haggard and Rovelli.

Carlos Barcel; Ral Carballo-Rubio; Luis J. Garay; Gil Jannes

2015-02-09T23:59:59.000Z

198

Development and Analysis of Desiccant Enhanced Evaporative Air Conditioner Prototype  

SciTech Connect (OSTI)

This report documents the design of a desiccant enhanced evaporative air conditioner (DEVAP AC) prototype and the testing to prove its performance. Previous numerical modeling and building energy simulations indicate a DEVAP AC can save significant energy compared to a conventional vapor compression AC (Kozubal et al. 2011). The purposes of this research were to build DEVAP prototypes, test them to validate the numerical model, and identify potential commercialization barriers.

Kozubal, E.; Woods, J.; Judkoff, R.

2012-04-01T23:59:59.000Z

199

K-Area and Par Pond Sewage Sludge Application Sites groundwater monitoring report: Second quarter 1993  

SciTech Connect (OSTI)

During second quarter 1993, samples from the three monitoring wells at the K-Area site (KSS series) and the three monitoring wells at the Par Pond site (PSS series) were analyzed for constituents required by South Carolina Department of Health and Environmental Control Construction Permit 13,173 and for other constituents as part of the Savannah River Site (SRS) Groundwater Monitoring Program. This report describes monitoring results that exceeded the final Primary Drinking Water Standards (PDWS) or the SRS flagging criteria. During second quarter 1993, no constituents exceeded the final PDWS or any other flagging criteria at the K-Area and Par Pond Sewage Sludge Application Sites. During first quarter 1993, aluminum and iron exceeded the SRS Flag 2 criteria in one or more of the KSS and the PSS wells. These constituents were not analyzed second quarter 1993. In the KSS well series, the field measurement for alkalinity ranged as high as 35 mg/L in well KSS 1D. Alkalinity measurements were zero in the PSS wells, except for a single measurement of 1 mg/L in well PSS 1D. Historical and current water-level elevations at the K-Area Sewage Sludge Application Site indicate that the groundwater flow direction is south to southwest (SRS grid coordinates). The groundwater flow direction at the Par Pond Sewage Sludge Application Site could not be determined second quarter 1993.

Not Available

1993-10-01T23:59:59.000Z

200

ENVIRONMENTAL PROBLEMS ASSOCIATED WITH DECOMMISSIONING THE CHERNOBYL NUCLEAR POWER PLANT COOLING POND  

SciTech Connect (OSTI)

Decommissioning of nuclear power plants and other nuclear fuel cycle facilities has been an imperative issue lately. There exist significant experience and generally accepted recommendations on remediation of lands with residual radioactive contamination; however, there are hardly any such recommendations on remediation of cooling ponds that, in most cases, are fairly large water reservoirs. The literature only describes remediation of minor reservoirs containing radioactive silt (a complete closure followed by preservation) or small water reservoirs resulting in reestablishing natural water flows. Problems associated with remediation of river reservoirs resulting in flooding of vast agricultural areas also have been described. In addition, the severity of environmental and economic problems related to the remedial activities is shown to exceed any potential benefits of these activities. One of the large, highly contaminated water reservoirs that require either remediation or closure is Karachay Lake near the MAYAK Production Association in the Chelyabinsk Region of Russia where liquid radioactive waste had been deep well injected for a long period of time. Backfilling of Karachay Lake is currently in progress. It should be noted that secondary environmental problems associated with its closure are considered to be of less importance since sustaining Karachay Lake would have presented a much higher radiological risk. Another well-known highly contaminated water reservoir is the Chernobyl Nuclear Power Plant (ChNPP) Cooling Pond, decommissioning of which is planned for the near future. This study summarizes the environmental problems associated with the ChNPP Cooling Pond decommissioning.

Farfan, E.

2009-09-30T23:59:59.000Z

Note: This page contains sample records for the topic "lined evaporation pond" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Environmental Problems Associated With Decommissioning The Chernobyl Nuclear Power Plant Cooling Pond  

SciTech Connect (OSTI)

Decommissioning of nuclear power plants and other nuclear fuel cycle facilities has been an imperative issue lately. There exist significant experience and generally accepted recommendations on remediation of lands with residual radioactive contamination; however, there are hardly any such recommendations on remediation of cooling ponds that, in most cases, are fairly large water reservoirs. The literature only describes remediation of minor reservoirs containing radioactive silt (a complete closure followed by preservation) or small water reservoirs resulting in reestablishing natural water flows. Problems associated with remediation of river reservoirs resulting in flooding of vast agricultural areas also have been described. In addition, the severity of environmental and economic problems related to the remedial activities is shown to exceed any potential benefits of these activities. One of the large, highly contaminated water reservoirs that require either remediation or closure is Karachay Lake near the MAYAK Production Association in the Chelyabinsk Region of Russia where liquid radioactive waste had been deep well injected for a long period of time. Backfilling of Karachay Lake is currently in progress. It should be noted that secondary environmental problems associated with its closure are considered to be of less importance since sustaining Karachay Lake would have presented a much higher radiological risk. Another well-known highly contaminated water reservoir is the Chernobyl Nuclear Power Plant (ChNPP) Cooling Pond, decommissioning of which is planned for the near future. This study summarizes the environmental problems associated with the ChNPP Cooling Pond decommissioning.

Farfan, E. B.; Jannik, G. T.; Marra, J. C.; Oskolkov, B. Ya.; Bondarkov, M. D.; Gaschak, S. P.; Maksymenko, A. M.; Maksymenko, V. M.; Martynenko, V. I.

2009-11-09T23:59:59.000Z

202

Torque on an exoplanet from an anisotropic evaporative wind  

E-Print Network [OSTI]

Winds from short-period Earth and Neptune mass exoplanets, driven by high energy radiation from a young star, may evaporate a significant fraction of a planet's mass. If the momentum flux from the evaporative wind is not aligned with the planet/star axis, then it can exert a torque on the planet's orbit. Using steady-state one-dimensional evaporative wind models we estimate this torque using a lag angle that depends on the product of the speed of the planet's upper atmosphere and a flow timescale for the wind to reach its sonic radius. We also estimate the momentum flux from time-dependent one-dimensional hydrodynamical simulations. We find that only in a very narrow regime in planet radius, mass and stellar radiation flux is a wind capable of exerting a significant torque on the planet's orbit. Similar to the Yarkovsky effect, the wind causes the planet to drift outward if atmospheric circulation is prograde (super-rotating) and in the opposite direction if the circulation is retrograde. A close-in super Ear...

Teyssandier, Jean; Adams, Fred C; Quillen, Alice C

2015-01-01T23:59:59.000Z

203

Techniques for evaluation of E-beam evaporative processes  

SciTech Connect (OSTI)

High dynamic range video imaging of the molten pool surface has provided insight regarding process responses at the melt pool liquid-vapor interface. A water-cooled video camera provides continuous high resolution imaging of the pool surface from a low angle position within 20 cm of the liquid-vapor interface. From the vantage point, the e-beam footprint is clearly defined and melt pool free surface shape can be observed. Effects of changes in a beam footprint, power distribution, and sweep frequency on pool surface shape and stability of vaporization are immediately shown. Other events observed and recorded include: formation of the pool and dissipation of ``rafts`` on the pool surface during startup, behavior of feed material as it enters the pool, effects of feed configuration changes on mixing of feed entering the pool volume and behaviors of co-evaporated materials of different vapor pressures at the feed/pool boundary. When used in conjunction with laser vapor monitoring, correlation between pool surface phenomena and vaporizer performance has been identified. This video capability was used in verifying the titanium evaporation model results presented at this conference by confirming the calculated melt pool surface deformations caused by vapor pressure of the departing evaporant at the liquid-vapor interface.

Meier, T.C.; Nelson, C.M.

1996-10-01T23:59:59.000Z

204

A Rinsing Effluent Evaporator for Dismantling Operations - 13271  

SciTech Connect (OSTI)

Between 1958 and 1997, the UP1 plant at Marcoule - located in the south of France - reprocessed and recycled nearly 20,000 MT of used fuel from special defense applications reactors, as well as fuel from the first generation of electricity generating reactors in France (natural uranium fuel, CO{sub 2}-cooled, graphite-moderated). Decommissioning and Dismantling of the UP1 plant and its associated units started in 1998. Since 2005, the UP1 facility has been operated by AREVA as the Marcoule Management and Operation contractor for French Atomic Energy Commission (CEA). An important part of this decommissioning program deals with the vitrification facility of Marcoule. This facility includes 20 tanks devoted to interim storage of highly active solutions, prior to vitrification. In 2006, a rinsing program was defined as part of the tank cleanup strategy. The main objective of the rinsing phases was to decrease activity in order to limit the volume of 'long-life active' waste produced during the decommissioning operations, so the tanks can be dismantled without the need of remote operations. To enable this rinsing program, and anticipating large volumes of generated effluent, the construction of an evaporation unit proved to be essential. The main objective of this unit was to concentrate the effluent produced during tank rinsing operations by a factor of approximately 10, prior to it being treated by vitrification. The evaporator design phase was launched in September 2006. The main challenge for the Project team was the installation of this new unit within a nuclear facility still in operation and in existing compartments not initially designed for this purpose. Cold operating tests were completed in 2008, and in May 2009, the final connections to the process were activated to start the hot test phase. During the first hot test operations performed on the first batches of clean-up effluent, the evaporator had a major operating problem. Extremely large quantities of foam were produced, affecting the evaporator operation, and creating the risk of a reduction in its capacity and throughput performance. A task force of AREVA process, operations, and safety experts from Marcoule and the La Hague reprocessing complex was assembled. New operating parameters were defined and tested to improve the process. Since then, the evaporator has performed very satisfactorily. The foam buildup phenomenon has been brought under complete control. All the different types of effluents produced during cleanup operations have been concentrated, and the results obtained in terms of quality and throughput, have ensured a consistent supply to the vitrification unit. The evaporator was operated until the end of April 2012, and enabled the production of 500 cubic meters of very high activity effluent, concentrating the fission products rinsed from the storage tanks. The evaporator will now be deactivated and decommissioned, with the first rinsing and cleanup operations scheduled to begin in 2014. (authors)

Rives, Rachel [AREVA BE/NV, Marcoule (France)] [AREVA BE/NV, Marcoule (France); Asou-Pothet, Marielle [CEA DEN/DPAD, Marcoule (France)] [CEA DEN/DPAD, Marcoule (France); Chambon, Frederic [AREVA FEDERAL SERVICES, Columbia, MD (United States)] [AREVA FEDERAL SERVICES, Columbia, MD (United States)

2013-07-01T23:59:59.000Z

205

Brackish water pond culture of fishes and their use as biological monitors of the water quality of thermal effluent from a power station  

E-Print Network [OSTI]

designed temperature change (bT) in the cooling water is 11. 1 C. Ponds Adjacent to the discharge canal are 25 ponds (Fig. 2); 16 ponds were used in this study. Each pond had 0. 1 ha suxface area and was 82. 3 m long, 12. 2 m wide, 1. 5 m deep... FIANT CEGAR RAVOU TRINITY BAY ~ 0 . . 000 ?' 8 OGLl II 0 Kll 0 'll El 9'll . 0 LI 0 GALVESTON BAY ll 'll ' I E RA 5 90 MAF AREA GULF OF MEXICO 9 SG Figure 1. --Map showing location of power plant and research facilities. DRAINAGE...

Kaehler, Todd

1975-01-01T23:59:59.000Z

206

Thermodynamics of an Evaporating Schwarzschild Black Hole in Noncommutative Space  

E-Print Network [OSTI]

We investigate the effects of space noncommutativity and the generalized uncertainty principle on the thermodynamics of a radiating Schwarzschild black hole. We show that evaporation process is in such a way that black hole reaches to a maximum temperature before its final stage of evolution and then cools down to a nonsingular remnant with zero temperature and entropy. We compare our results with more reliable results of string theory. This comparison Shows that GUP and space noncommutativity are similar concepts at least from view point of black hole thermodynamics.

Kourosh Nozari; Behnaz Fazlpour

2007-01-14T23:59:59.000Z

207

The development of a new evaporation formula for Texas  

E-Print Network [OSTI]

of Texas. From these maps an equation for evapo- ration can be extracted for any location in Texas. It was found that wind speed and relative humidity had little effect on evaporation from pans in Texas, at least when considered in terms of mean... meteorological parameters, such as temperature, wind speed, and relative humidity. These investigations have often been hampered by a lack of reliable data and non-standard instrumenta- tion. In addition, there has been a great deal of con- troversy over...

Moe, R. D

2012-06-07T23:59:59.000Z

208

2012 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site's Advanced Test Reactor Complex Cold Waste Pond  

SciTech Connect (OSTI)

This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (#LA 000161 01, Modification B), for the wastewater land application site at the Idaho National Laboratory Sites Advanced Test Reactor Complex Cold Waste Pond from November 1, 2011 through October 31, 2012. The report contains the following information: Facility and system description Permit required effluent monitoring data and loading rates Groundwater monitoring data Status of compliance activities Noncompliance issues Discussion of the facilitys environmental impacts During the 2012 permit year, approximately 183 million gallons of wastewater were discharged to the Cold Waste Pond. This is well below the maximum annual permit limit of 375 million gallons. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest near the Cold Waste Pond and decrease rapidly as the distance from the Cold Waste Pond increases. Although concentrations of sulfate and total dissolved solids are elevated near the Cold Waste Pond, both parameters were below the Ground Water Quality Rule Secondary Constituent Standards in the down gradient monitoring wells.

Mike Lewis

2013-02-01T23:59:59.000Z

209

2011 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site's Advanced Test Reactor Complex Cold Waste Pond  

SciTech Connect (OSTI)

This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (LA 000161 01, Modification B), for the wastewater land application site at the Idaho National Laboratory Site's Advanced Test Reactor Complex Cold Waste Pond from November 1, 2010 through October 31, 2011. The report contains the following information: Facility and system description Permit required effluent monitoring data and loading rates Groundwater monitoring data Status of compliance activities Noncompliance and other issues Discussion of the facility's environmental impacts During the 2011 permit year, approximately 166 million gallons of wastewater were discharged to the Cold Waste Pond. This is well below the maximum annual permit limit of 375 million gallons. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest near the Cold Waste Pond and decrease rapidly as the distance from the Cold Waste Pond increases. Although concentrations of sulfate and total dissolved solids are elevated near the Cold Waste Pond, both parameters were below the Ground Water Quality Rule Secondary Constituent Standards in the down gradient monitoring wells.

Mike Lewis

2012-02-01T23:59:59.000Z

210

On the interface instability during rapid evaporation in microgravity  

SciTech Connect (OSTI)

The rapid evaporation of a superheated liquid (vapor explosion) under microgravity conditions is studied by direct numerical simulation. The time-dependent Navier-Stokes and energy equations coupled to the interface dynamics are solved using a two-dimensional finite-difference/front-tracking method. Large interface deformations, topology change, latent heat, surface tension and unequal material properties between the liquid and vapor phases are included in the simulations. A comparison of numerical results to the exact solution of a one-dimensional test problem shows excellent agreement. For the two-dimensional rapid evaporation problem, the vapor volume growth rate and unstable interface dynamics are studied for increasing levels of initial liquid superheat. As the superheat is increased the liquid-vapor interface experiences increasingly unstable energetic growth. These results indicate that heat transfer plays a very important role in the instability mechanism leading to vapor explosions. It is suggested that the Mullins-Sekerka instability could play a role in the instability initiation mechanism.

Juric, D. [Los Alamos National Lab., NM (United States). Theoretical Div.

1997-05-01T23:59:59.000Z

211

Power line carrier interference from HVDC converter terminals  

SciTech Connect (OSTI)

Power line carrier (PLC) equipment typically operates in the frequency range from 25 kHz to 300 kHz. Interference studies for HVDC converters usually concentrate on interference from noise sources within this frequency range. However, operating experience at the Sandy Pond converter terminal has indicated that PLC equipment is also susceptible to interference from sources of power system harmonics below the PLC frequency range. Extensive field testing and analytical studies have shown that each PLC circuit has a resonant frequency below the operating frequency. If excited at this resonant frequency, high voltages may exist within the PLC circuit. The resulting saturation of PLC components leads to local generation of radio frequency (RF) noise that interferes with proper operation of PLC circuits. Sources of power system harmonics in the 3-10 kHz range, such as line commutated dc converters, are potential sources of this type of interference.

Tatro, P.J.; Adamson, K.A. (New England Power Service Co., Westborough, MA (United States)); Eitzmann, M.A.; Smead, M. (GE Industrial and Power Systems, Schenectady, NY (United States). Power Systems Engineering Dept.)

1993-07-01T23:59:59.000Z

212

Effect of surfactant on evaporative heat transfer coefficients in vertical film forced convection  

E-Print Network [OSTI]

for different concentrations of surfactant (log-log scale) (Boiling liquid flow rate of 1. 025 gpm) Evaporative coefficient as function of tempera- ture drop over the liquid film for different concentrations of surfactant (log-log scale) (Boiling liquid... flow rate of 1. 275 gpm) Evaporative coefficient as function of tempera- ture drop over the liquid film for different concentrations of surfactant (log-log scale) (Boiling liquid flow rate of 1. 55 gpm) 47 84 85 86 87 10 Evaporative...

Shah, Basit Husain

1972-01-01T23:59:59.000Z

213

Use of DOE-2 to Evaluate Evaporative Cooling in Texas Correctional Facilities  

E-Print Network [OSTI]

, W.K., "Fundamental Concepts Integrating Evaporative Techniques in HVAC Systems," ASHRAE TRANSACTIONS, V. 96, Pt. 1, 1990. 3. McDonald, G.W., M.H. Turietta and R.E. Foster, "Modeling Evaporative Cooling Systems with DOE- 2. ID," ASHRAE...USE OF DOE-2 TO EVALUATE EVAPORATIVE COOLING IN TEXAS CORRECTIONAL FACILITIES Namir Saman, Ph.D., P.E. Tarek Bou-Saada Tia Heneghan Visiting Assistant Professor Research Associate Energy Manager Energy Systems Laboratory Energy Systems...

Saman, N.; Heneghan, T.; Bou-Saada, T. E.

1996-01-01T23:59:59.000Z

214

The use of carbonation and fractional evaporative crystallization in the pretreatment of Hanford nuclear wastes.  

E-Print Network [OSTI]

??The purpose of this work was to explore the use of fractional evaporative crystallization as a technology that can be used to separate medium-curie waste (more)

Dumont, George Pierre, Jr.

2007-01-01T23:59:59.000Z

215

An integrated study of dietary lipid manipulation and thermal-refuge technology for overwintering red drum (Sciaenops ocellatus) in outdoor ponds  

E-Print Network [OSTI]

of consuming these diets, subgroups of fish were stocked into 8, 0.04-ha earthen ponds, with or without thermal refuges, during January 1994. The thermal refuges, consisting of air-inflated domes of plastic sheeting covering one end of affected ponds, were...

Boren, Ronald Scott

1995-01-01T23:59:59.000Z

216

Selecting a Method for Sealing Ponds in Florida1 Dorota Z. Haman, Allen G. Smajstrla, Fedro S. Zazueta, and Gary A. Clark2  

E-Print Network [OSTI]

257) or, as some retention ponds in south Florida, created by building a dike around a water storage in South Florida are required on all new agricultural developments for runoff control, water quality control and a recharge of the shallow aquifer. In some cases, water from these ponds is also reused

Watson, Craig A.

217

Ponding Test Results Seepage Losses Laterals 8E and 2A-C, Maverick County Water Control and Improvement District No. 1  

E-Print Network [OSTI]

TR-336 2008 Ponding Test Results Seepage Losses Laterals 8E and 2A-C Maverick County Water Control and Improvement District No. 1 By: Eric Leigh, Extension Associate, Biological and Agricultural... Engineering Guy Fipps, Professor and Extension Agricultural Engineer, Biological and Agricultural Engineering Texas Water Resources Institute Technical Report November 2008 PONDING TEST RESULTS SEEPAGE LOSSES LATERALS 8E AND 2A...

Leigh, Eric; Fipps, Guy

218

Harvesting Ornamental Fish From Ponds1 Tina C. Crosby, Jeffrey E. Hill, Carlos V. Martinez, Craig A. Watson, Deborah B. Pouder, and Roy  

E-Print Network [OSTI]

FA-117 Harvesting Ornamental Fish From Ponds1 Tina C. Crosby, Jeffrey E. Hill, Carlos V. Martinez, ornamental fish are predominantly farmed in earthen ponds. Once fish reach marketable size and are ready and physical damage during harvesting (see UF IFAS Circular 919 Stress-Its Role in Fish Disease). Overall, col

Watson, Craig A.

219

Accepted, subject to re-review, Journal of Hydraulic Engineering, ASCE, version of January 2006 Role of Ponded Turbidity Currents in Reservoir Trap Efficiency  

E-Print Network [OSTI]

, because some of this sediment may pass out of the reservoir without settling out. Here a model of trap. The dam causes a sustained turbidity current to reflect and form a muddy pond bounded upstream by a hydraulic jump. If the interface of this muddy pond rises above any vent or overflow point at the dam

Parker, Gary

220

Direct mass measurements beyond the proton drip-line  

E-Print Network [OSTI]

First on-line mass measurements were performed at the SHIPTRAP Penning trap mass spectrometer. The masses of 18 neutron-deficient isotopes in the terbium-to-thulium region produced in fusion-evaporation reactions were determined with relative uncertainties of about $7\\cdot 10^{-8}$, nine of them for the first time. Four nuclides ($^{144, 145}$Ho and $^{147, 148}$Tm) were found to be proton-unbound. The implication of the results on the location of the proton drip-line is discussed by analyzing the one-proton separation energies.

C. Rauth; D. Ackermann; K. Blaum; M. Block; A. Chaudhuri; S. Eliseev; R. Ferrer; D. Habs; F. Herfurth; F. P. Hessberger; S. Hofmann; H. -J. Kluge; G. Maero; A. Martin; G. Marx; M. Mukherjee; J. B. Neumayr; W. R. Plass; W. Quint; S. Rahaman; D. Rodriguez; C. Scheidenberger; L. Schweikhard; P. G. Thirolf; G. Vorobjev; C. Weber; Z. Di

2007-01-22T23:59:59.000Z

Note: This page contains sample records for the topic "lined evaporation pond" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Melt and vapor characteristics in an electron beam evaporator  

SciTech Connect (OSTI)

We compare the free surface temperatures T{sub s}, calculated by two methods, in cerium or copper evaporation experiments. The first method considers properties of the melt: by an empirical law we take into account turbulent thermal convection, instabilities and craterization of the free surface. The second method considers the vapor flow expansion and connects T{sub s} to the measured terminal parallel temperature and the terminal mean parallel velocity of the vapor jet, by Direct Simulation Monte Carlo calculations including an atom-atom inelastic collision algorithm. The agreement between the two approaches is better for cerium than for copper in the high craterization case. The analysis, from the point of view of the properties of the melt, of the terminal parameters of the vapor jet for the high beam powers shows that T{sub s} and the Knudsen number at the vapor source reach a threshold when the beam power increases.

Blumenfeld, L.; Fleche, J.L.; Gonella, C. [DCC/DPE/SPEA Centre d`Etudes de Saclay, Gif-sur-Yvette (France)

1994-12-31T23:59:59.000Z

222

Modelling the Evaporation of Non-singular Black Holes  

E-Print Network [OSTI]

We present a model for studying the formation and evaporation of non-singular (quantum corrected) black holes. The model is based on a generalized form of the dimensionally reduced, spherically symmetric Einstein--Hilbert action and includes a suitably generalized Polyakov action to provide a mechanism for radiation back-reaction. The equations of motion describing self-gravitating scalar field collapse are derived in local form both in null co--ordinates and in Painleve--Gullstrand (flat slice) co--ordinates. They provide the starting point for numerical studies of complete spacetimes containing dynamical horizons that bound a compact trapped region. Such spacetimes have been proposed in the past as solutions to the information loss problem because they possess neither an event horizon nor a singularity. Since the equations of motion in our model are derived from a diffeomorphism invariant action they preserve the constraint algebra and the resulting energy momentum tensor is manifestly conserved.

Tim Taves; Gabor Kunstatter

2015-01-11T23:59:59.000Z

223

Fixture for forming evaporative pattern (EPC) process patterns  

DOE Patents [OSTI]

A method of casting metal using evaporative pattern casting process patterns in combination with a fixture for creating and maintaining a desired configuration in flexible patterns. A pattern is constructed and gently bent to the curvature of a suitable fixture. String or thin wire, which burns off during casting, is used to tie the pattern to the fixture. The fixture with pattern is dipped in a commercially available refractory wash to prevent metal adherence and sticking to the fixture. When the refractory wash is dry, the fixture and pattern are placed in a flask, and sand is added and compacted by vibration. The pattern remains in position, restrained by the fixture. Metal that is poured directly into the pattern replaces the pattern exactly but does not contact or weld to the fixture due to the protective refractory layer. When solid, the casting is easily separated from the fixture. The fixture can be cleaned for reuse in conventional casting cleaning equipment.

Turner, Paul C. (Albany, OR); Jordan, Ronald R. (Albany, OR); Hansen, Jeffrey S. (Corvallis, OR)

1993-01-01T23:59:59.000Z

224

A graphics processor-based intranuclear cascade and evaporation simulation  

E-Print Network [OSTI]

Monte Carlo simulations of the transport of protons in human tissue have been deployed on graphics processing units (GPUs) with impressive results. To provide a more complete treatment of non-elastic nuclear interactions in these simulations, we developed a fast intranuclear cascade-evaporation simulation for the GPU. This can be used to model non-elastic proton collisions on any therapeutically relevant nuclei at incident energies between 20 and 250 MeV. Predictions are in good agreement with Geant4.9.6p2. It takes approximately 2 s to calculate $1\\times 10^6$ 200 MeV proton-$^{16}$O interactions on a NVIDIA GTX680 GPU. A speed-up factor of $\\sim$20 relative to one Intel i7-3820 core processor thread was achieved.

H. Wan Chan Tseung; C. Beltran

2014-02-19T23:59:59.000Z

225

Mathematical modeling of evaporative cooling of moisture bearing epoxy composite plates  

E-Print Network [OSTI]

of Composite Materials. 2 EVAPORATIVE COOLING Evaporative cooling is deemed to be an appropriate alternative mechanism for the cooling of stealth aircraft due to its simplicity, as well as its success as a cooling mechanism in other applications... Element Assembly 34 Boundary Conditions 36 viii CHAPTER Page Convective Heat Transfer Coefficients 46 Convective Mass Transfer Coefficients 50 Material Properties 52 Time Step Approximations 54...

Payette, Gregory Steven

2006-08-16T23:59:59.000Z

226

Temperature Effect on Pump Oil and Alkanes Evaporation Nathaniel A. Waldstein and Alex A. Volinsky  

E-Print Network [OSTI]

temperatures than in the past. The greater the operating temperature the faster the lubricating oil in the hardTemperature Effect on Pump Oil and Alkanes Evaporation Nathaniel A. Waldstein and Alex A. Volinsky of several milligrams, of lubricants for proper operation. The following study investigated the evaporation

Volinsky, Alex A.

227

CORRELATING EVAPORATION HEAT TRANSFER COEFFICIENT OF REFRIGERANT R-134a IN A PLATE HEAT EXCHANGER  

E-Print Network [OSTI]

1 CORRELATING EVAPORATION HEAT TRANSFER COEFFICIENT OF REFRIGERANT R-134a IN A PLATE HEAT EXCHANGER for evaporation heat transfer coefficient of refrigerant R-134a flowing in a plate heat exchanger. Correlation schemes proposed by Yan and Lin (1999b) for modeling the heat transfer coefficient in both a single- phase

Kandlikar, Satish

228

Control Structure Selection for an Evaporation Process Marius S. Govatsmark a , Sigurd Skogestad a  

E-Print Network [OSTI]

of controlled variables which with constant setpoints keep the process close to the economic optimum ("self1 Control Structure Selection for an Evaporation Process Marius S. Govatsmark a , Sigurd Skogestad structure selection is applied to the evaporation process of Newell and Lee (1989). First, promising sets

Skogestad, Sigurd

229

REAR-SIDE POINT-CONTACTS BY INLINE THERMAL EVAPORATION OF ALUMINUM Christoph Mader  

E-Print Network [OSTI]

REAR-SIDE POINT-CONTACTS BY INLINE THERMAL EVAPORATION OF ALUMINUM Christoph Mader 1 , Jens Müller of point-contacted aluminum rear-sides for silicon solar cells that are metalized by inline thermal evaporation. We deposit aluminum layers of 2 µm thickness at dynamic deposition rates of 1.0, 2.9 and 5.0 µm

230

EVAPORATION LAW IN KINETIC GRAVITATIONAL SYSTEMS DESCRIBED BY SIMPLIFIED LANDAU MODELS  

E-Print Network [OSTI]

EVAPORATION LAW IN KINETIC GRAVITATIONAL SYSTEMS DESCRIBED BY SIMPLIFIED LANDAU MODELS PIERRE to a mathematical and numerical study of a simplified kinetic model for evaporation phenomena in gravitational) is the gravitational potential and (u) is the following 3 ? 3 matrix (u)ij = |u|2ij - uiuj |u|2 , (1.2) 1 #12;2 P

Méhats, Florian

231

Kinetics for evaporative cooling of a trapped gas Kirstine BergSrensen \\Lambda  

E-Print Network [OSTI]

the kinetic theory for evaporative cooling of a dilute collisional gas in a trap. The analysis in 0. J. Luiten and increase the phase­space density of an atomic, bosonic gas towards a Bose­Einstein condensate (BECKinetics for evaporative cooling of a trapped gas Kirstine Berg­Sørensen \\Lambda The Rowland

Berg-Sørensen, Kirstine

232

LETTER doi:10.1038/nature11718 Evaporative cooling of the dipolar hydroxyl radical  

E-Print Network [OSTI]

direct cooling and cold-association techniques, evaporative cooling has not been achieved so far-temperature sensi- tivity of our spectroscopic thermometry technique. With evapora- tive cooling and a sufficientlyLETTER doi:10.1038/nature11718 Evaporative cooling of the dipolar hydroxyl radical Benjamin K

233

Ultracold molecules for the masses: evaporative cooling and magneto-optical trapping  

E-Print Network [OSTI]

cooling, until now none of these techniques have been applicable to molecules. In this thesis, two majorUltracold molecules for the masses: evaporative cooling and magneto-optical trapping by B. K. Stuhl for the masses: evaporative cooling and magneto-optical trapping written by B. K. Stuhl has been approved

Jin, Deborah

234

Speciation of Zn in Blast Furnace Sludge from Former Sedimentation Ponds Using Synchrotron Xray Diffraction, Fluorescence, and  

E-Print Network [OSTI]

, University of Cologne, Albertus-Magnus-Platz, D-50923 Koln, Germany § Advanced Light Source, Lawrence *S Supporting Information ABSTRACT: Blast furnace sludge (BFS), an industrial waste generated in pig on a former BFS sedimentation pond site. Additionally, one fresh BFS was analyzed for comparison. We

235

Corrective Action Investigation Plan for Corrective Action Unit 552: Area 12 Muckpile and Ponds, Nevada Test Site, Nevada: Revision 0  

SciTech Connect (OSTI)

This Corrective Action Investigation Plan contains the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office's approach for collecting the data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit (CAU) 552: Area 12 Muckpile and Ponds, Nevada Test Site (NTS), Nevada, under the Federal Facility Agreement and Consent Order. Located in Area 12 on the NTS, CAU 552 consists of two Corrective Action Sites (CASs): 12-06-04, Muckpile; 12-23-05, Ponds. Corrective Action Site 12-06-04 in Area 12 consists of the G-Tunnel muckpile, which is the result of tunneling activities. Corrective Action Site 12-23-05 consists of three dry ponds adjacent to the muckpile. The toe of the muckpile extends into one of the ponds creating an overlap of two CASs. The purpose of the investigation is to ensure that adequate data are collected to provide sufficient and reliable information to identify, evaluate, and select technic ally viable corrective actions. The results of the field investigation will support a defensible evaluation of corrective action alternatives in the corrective action decision document.

U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office

2004-04-06T23:59:59.000Z

236

Evaporation a key mechanism for the thaumasite form of sulfate attack  

SciTech Connect (OSTI)

Understanding the mechanisms leading to chemical attack on concrete is crucial in order to prevent damage of concrete structures. To date, most studies on sulfate attack and thaumasite formation are based on empirical approaches, as the identification of associated reaction mechanisms and paths is known to be highly complex. In this study, sulfate damaged concrete from Austrian tunnels was investigated by mineralogical, chemical and isotope methods to identify the reactions which caused intense concrete alteration. Major, minor and trace elemental contents as well as isotope ratios of local ground water (GW), drainage water (DW) and interstitial solutions (IS), extracted from damaged concrete material, were analyzed. Locally occurring GW contained 3 to 545 mg L{sup ?1} of SO{sub 4} and is thus regarded as slightly aggressive to concrete in accordance to standard specifications (e.g. DIN EN 206-1). The concrete linings and drainage systems of the studied tunnels, however, have partly suffered from intensive sulfate attack. Heavily damaged concrete consisted mainly of thaumasite, secondary calcite, gypsum, and relicts of aggregates. Surprisingly, the concentrations of dissolved ions were extremely enriched in the IS with up to 30,000 and 12,000 mg L{sup ?1} of SO{sub 4} and Cl, respectively. Analyses of aqueous ions with a highly conservative behavior, e.g. K, Rb and Li, as well as {sup 2}H/H and {sup 18}O/{sup 16}O isotope ratios of H{sub 2}O of the IS showed an intensive accumulation of ions and discrimination of the light isotopes vs. the GW. These isotope signals of the IS clearly revealed evaporation at distinct relative humidities. From ion accumulation and isotope fractionation individual total and current evaporation degrees were estimated. Our combined elemental and isotopic approach verified wettingdrying cycles within a highly dynamic concrete-solution-atmosphere system. Based on these boundary conditions, key factors controlling thaumasite formation are discussed regarding the development of more sulfate-resistant concrete and concrete structures.

Mittermayr, Florian, E-mail: f.mittermayr@tugraz.at [Graz University of Technology, Institute of Applied Geosciences, Rechbauerstrae 12, 8010 GRAZ (Austria)] [Graz University of Technology, Institute of Applied Geosciences, Rechbauerstrae 12, 8010 GRAZ (Austria); Baldermann, Andre [Graz University of Technology, Institute of Applied Geosciences, Rechbauerstrae 12, 8010 GRAZ (Austria)] [Graz University of Technology, Institute of Applied Geosciences, Rechbauerstrae 12, 8010 GRAZ (Austria); Kurta, Christoph [University of Graz, Institute of Chemistry Analytical Chemistry, Stremayrgasse 16/III, 8010 GRAZ (Austria)] [University of Graz, Institute of Chemistry Analytical Chemistry, Stremayrgasse 16/III, 8010 GRAZ (Austria); Rinder, Thomas [Graz University of Technology, Institute of Applied Geosciences, Rechbauerstrae 12, 8010 GRAZ (Austria) [Graz University of Technology, Institute of Applied Geosciences, Rechbauerstrae 12, 8010 GRAZ (Austria); Observatoire Midi-Pyrnes, Laboratoire Gosciences Environnement Toulouse, 14, avenue Edouard Belin, 31400 TOULOUSE (France); Klammer, Dietmar [Graz University of Technology, Institute of Applied Geosciences, Rechbauerstrae 12, 8010 GRAZ (Austria)] [Graz University of Technology, Institute of Applied Geosciences, Rechbauerstrae 12, 8010 GRAZ (Austria); Leis, Albrecht [Joanneum Research, Resources Institute for Water, Energy and Sustainability, Elisabethstrae 18/2, 8010 GRAZ (Austria)] [Joanneum Research, Resources Institute for Water, Energy and Sustainability, Elisabethstrae 18/2, 8010 GRAZ (Austria); Tritthart, Josef [Graz University of Technology, Institute of Technology and Testing of Building Materials, Inffeldgasse 24, 8010 GRAZ (Austria)] [Graz University of Technology, Institute of Technology and Testing of Building Materials, Inffeldgasse 24, 8010 GRAZ (Austria); Dietzel, Martin [Graz University of Technology, Institute of Applied Geosciences, Rechbauerstrae 12, 8010 GRAZ (Austria)] [Graz University of Technology, Institute of Applied Geosciences, Rechbauerstrae 12, 8010 GRAZ (Austria)

2013-07-15T23:59:59.000Z

237

Steam oxidation and chromia evaporation in ultrasupercritical steam boilers and turbines  

SciTech Connect (OSTI)

The U.S. Department of Energy's goals include power generation from coal at 60% efficiency, which requires steam conditions of up to 760 {sup o}C and 340 atm, so-called ultrasupercritical conditions. Evaporation of protective chromia scales is a primary corrosion mechanism. A methodology to calculate Cr evaporation rates from chromia scales was developed and combined with Cr diffusion calculations within the alloy (with a constant flux of Cr leaving the alloy from evaporation) to predict Cr concentration profiles and to predict the time until breakaway oxidation. At the highest temperatures and pressures, the time until breakaway oxidation was quite short for the turbine blade, and of concern within the steam pipe and the higher temperature portions of the superheater tube. Alloy additions such as Ti may allow for a reduction in evaporation rate with time, mitigating the deleterious effects of chromia evaporation.

Holcomb, G.R. [US DOE, Albany, OR (United States)

2009-07-01T23:59:59.000Z

238

Steam Oxidation and Chromia Evaporation in Ultra-Supercritical Steam Boilers and Turbines  

SciTech Connect (OSTI)

U.S. Department of Energys goals include power generation from coal at 60% efficiency, which requires steam conditions of up to 760 C and 340 atm, so-called ultra-supercritical (USC) conditions. Evaporation of protective chromia scales is expected to be a primary corrosion mechanism. A methodology to calculate Cr evaporation rates from chromia scales was developed and combined with Cr diffusion calculations within the alloy (with a constant flux of Cr leaving the alloy from evaporation) to predict Cr concentration profiles and to predict the time until breakaway oxidation. At the highest temperatures and pressures, the time until breakaway oxidation was predicted to be quite short for the turbine blade, and of concern within the steam pipe and the higher temperature portions of the superheater tube. Alloy additions such as Ti may allow for a reduction in evaporation rate with time, mitigating the deleterious effects of chromia evaporation.

Gordon H. Holcomb

2009-01-01T23:59:59.000Z

239

High temperature lined conduits, elbows and tees  

DOE Patents [OSTI]

A high temperature lined conduit comprising, a liner, a flexible insulating refractory blanket around and in contact with the liner, a pipe member around the blanket and spaced therefrom, and castable rigid refractory material between the pipe member and the blanket. Anchors are connected to the inside diameter of the pipe and extend into the castable material. The liner includes male and female slip joint ends for permitting thermal expansion of the liner with respect to the castable material and the pipe member. Elbows and tees of the lined conduit comprise an elbow liner wrapped with insulating refractory blanket material around which is disposed a spaced elbow pipe member with castable refractory material between the blanket material and the elbow pipe member. A reinforcing band is connected to the elbow liner at an intermediate location thereon from which extend a plurality of hollow tubes or pins which extend into the castable material to anchor the lined elbow and permit thermal expansion. A method of fabricating the high temperature lined conduit, elbows and tees is also disclosed which utilizes a polyethylene layer over the refractory blanket after it has been compressed to maintain the refractory blanket in a compressed condition until the castable material is in place. Hot gases are then directed through the interior of the liner for evaporating the polyethylene and setting the castable material which permits the compressed blanket to come into close contact with the castable material.

De Feo, Angelo (Passaic, NJ); Drewniany, Edward (Bergen, NJ)

1982-01-01T23:59:59.000Z

240

The culture of some marine fishes in ponds receiving heated discharge water from a power plant  

E-Print Network [OSTI]

and sampled to determine survival, growth, condition, and for saltmarsh species reproduction: bay anchovy, Anchoa 'tch'lll (Valenc' nnes); h epshead m'n ow, ~Cr' r t Led:*oc'tfth, Gb ff'1(a'Md Gt d); a'lf' molly, P '1'a~tt' 'n (L ); lfd wats 'Iv 'd, M 'd...' beryl)'n (C p ); Pl 'da p p, P ht t 1 (Lf );Atl t' k, ~Mt d lt (L' 1; bl kd om, P~ac 's (Id eos); reddr, ~dc' n* o ll t (L' ): t 'p d list, ~Mtt ~ht 11 LITERATURE REVIEW Pond culture of fish has been going on for centuries virtually throughout...

Luebke, Richard William

2012-06-07T23:59:59.000Z

Note: This page contains sample records for the topic "lined evaporation pond" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Ground water impact assessment report for the 216-B-3 Pond system  

SciTech Connect (OSTI)

Ground water impact assessments were required for a number of liquid effluent receiving sites according to the Hanford Federal Facility Agreement and Consent Order Milestones M-17-00A and M-17-00B, as agreed upon by the US Department of Energy. This report is one of the last three assessments required and addresses the impact of continued discharge of uncontaminated wastewater to the 216-B-3C expansion lobe of the B Pond system in the 200 East Area until June 1997. Evaluation of past and projected effluent volumes and composition, geohydrology of the receiving site, and contaminant plume distribution patterns, combined with ground water modeling, were used to assess both changes in ground water flow regime and contaminant-related impacts.

Johnson, V.G.; Law, A.G.; Reidel, S.P.; Evelo, S.D.; Barnett, D.B.; Sweeney, M.D.

1995-01-01T23:59:59.000Z

242

Post-Closure RCRA Groundwater Monitoring Plan for the 216-S-10 Pond and Ditch  

SciTech Connect (OSTI)

The purpose of this plan is to provide a post-closure groundwater monitoring program for the 216-S-10 Pond and Ditch (S-10) treatment, storage, and/or disposal (TSD) unit. The plan incorporates the sum of knowledge about the potential for groundwater contamination to originate from the S-10, including groundwater monitoring results, hydrogeology, and operational history. The S-10 has not received liquid waste since October 1991. The closure of S-10 has been coordinated with the 200-CS-1 source operable unit in accordance with the Tri-Party Agreement interim milestones M-20-39 and M-15-39C. The S-10 is closely situated among other waste sites of very similar operational histories. The proximity of the S-10 to the other facilities (216-S-17 pond, 216-S-11 Pond, 216-S-5,6 cribs, 216-S-16 ditch and pond, and 216-U-9 ditch) indicate that at least some observed groundwater contamination beneath and downgradient of S-10 could have originated from waste sites other than S-10. Hence, it may not be feasible to strictly discriminate between the contributions of each waste site to groundwater contamination beneath the S-10. A post-closure groundwater monitoring network is proposed that will include the drilling of three new wells to replace wells that have gone dry. When completed, the revised network will meet the intent for groundwater monitoring network under WAC 173-303-645, and enable an improved understanding of groundwater contamination at the S-10. Site-specific sampling constituents are based on the dangerous waste constituents of concern relating to RCRA TSD unit operations (TSD unit constituents) identified in the Part A Permit Application. Thus, a constituent is selected for monitoring if it is: A dangerous waste constituent identified in the Part A Permit Application, or A mobile decomposition product (i.e., nitrate from nitrite) of a Part A constituent, or A reliable indicator of the site-specific contaminants (i.e., specific conductance). Using these criteria, the following constituent list and sampling schedule is proposed: Constituent; Sampling Frequency Site-Specific Parameters; Hexavalent chromium (a); Semiannual Chloride; Semiannual Fluoride; Semiannual Nitrate; Semiannual Nitrite; Semiannual Specific conductance (field)(a); Semiannual Ancillary Parameters; Anions; Annual Alkalinity Annual Metals, (in addition to chromium); Annual pH (field) Semiannual Temperature (field); Semiannual Turbidity (field) Semiannual (a). These constituents will be subject to statistical tests after background is established. It will be necessary to install new monitoring wells and accumulate background data on the groundwater from those wells before statistical comparisons can be made. Until then, the constituents listed above will be evaluated by tracking and trending concentrations in all wells and comparing these results with the corresponding DWS or Hanford Site background concentration for each constituent. If a comparison value (background or DWS) for a constituent is exceeded, DOE will notify Ecology per WAC 173-303-645 (9) (g) requirements (within seven days or a time agreed to between DOE and Ecology).

Barnett, D BRENT.; Williams, Bruce A.; Chou, Charissa J.; Hartman, Mary J.

2006-03-17T23:59:59.000Z

243

Inventory of Ponds in the Brazos and Colorado River (Texas) Drainages, from NASA Color Infrared Photography.  

E-Print Network [OSTI]

, we decided to carry out the stepwise regression on the densi ty of each of the different size 7 '0 c o :; u cu -LL 1.5 A. All Ponds 1.2 6. 0.9 ? ? 6. ?????? 6. ??? ? ?? ? eI ?? .. , .. ., ..... O... FRMX FRMX POPD POPD FRMX FRMX R2 0.125 0.206 0.262 0.296 0.313 0.321 0.324 0.352 0.372 PROB) F 0.0026 0.0004 0.0002 0.0001 0.0002 0.0001 0.0001 0.0001 0.0001 * Underlined variables were significant at ex = 20.05. Doubly underlined variables...

Clark, William J.; Springer, Timothy A.

1986-01-01T23:59:59.000Z

244

Post-Closure Inspection Report for Corrective Action Unit 92: Area 6 Decon Pond Facility  

SciTech Connect (OSTI)

This Post-Closure Inspection Report provides an analysis and summary of inspections for Corrective Action Unit (CAU) 92, Area 6 Decon Pond Facility. CAU 92 was closed according to the Resource Conservation and Recovery Act (RCRA) Part B Operational Permit (Nevada Division of Environmental Protection [NDEP], 1995) and the Federal Facility Agreement and Consent Order (FFACO) of 1996 (FFACO, 1996; as amended January 2007). Closure activities were completed on February 16, 1999, and the Closure Report (U.S. Department of Energy, Nevada Operations Office, 1999) was approved and a Notice of Completion issued by NDEP on May 11, 1999. CAU 92 consists of two Corrective Action Sites (CASs): CAS 06-04-01, Decon Pad Oil/Water Separator, and CAS 06-05-02, Decontamination Pond (RCRA). Both CASs have use restrictions; however, only CAS 06-05-02 requires post-closure inspections. Visual inspections of the cover and fencing at CAS 06-05-02 are performed quarterly. Additional inspections are conducted if precipitation occurs in excess of 1.28 centimeters (cm) (0.50 inches [in.]) in a 24-hour period. This report covers calendar year 2007. Quarterly site inspections were performed in March, June, September, and December of 2007. All observations indicated the continued integrity of the unit. No issues or concerns were noted, and no corrective actions were necessary. Copies of the inspection checklists and field notes completed during each inspection are included in Appendix A of this report, and photographs taken during the site inspections are included in Appendix B of this report. Two additional inspections were performed after precipitation events that exceeded 1.28 cm (0.50 in.) within a 24-hour period during 2007. No significant changes in site conditions were noted during these inspections, and no corrective actions were necessary. A copy of the inspection checklists and field notes completed during these additional inspections are included in Appendix A. Precipitation records for 2007 are included in Appendix C.

NSTec Environmental Restoration

2008-03-01T23:59:59.000Z

245

Remaining Sites Verification Package for the 100-F-33, 146-F Aquatic Biology Fish Ponds, Waste Site Reclassification Form 2006-021  

SciTech Connect (OSTI)

The 100-F-33, 146-F Aquatice Biology Fish Ponds waste site was an area with six small rectangular ponds and one large circular pond used to conduct tests on fish using various mixtures of river and reactor effluent water. The current site conditions achieve the remedial action objectives specified in the Remaining Sites ROD. The results of verification and applicable confirmatory sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

L. M. Dittmer

2006-08-25T23:59:59.000Z

246

The culture of Penaeid shrimp in ponds receiving heated discharge water from a steam electric generating station, and their use as indicators of water quality  

E-Print Network [OSTI]

shrimp in pond 6 stocked at 5, 000 shrimp/ha with a survaval of 80. 6% 48 Growth and condition data for fed brown shrimp in pond 7 stocked at 5, 000 shrimp/ha with a survival of 81. 0% . . 49 Type and composition of food used in all experiments... at 500 shrimp/ha with a survival of 100m 65 17 Growth and condition data for fed white shrimp in pond 7 stocked at 500 shrimp/ha with a survival of 100% 66 18 Summary of results of the white shrimp experiment based on data collected on October 17...

Reitsema, Lawrence Alan

1975-01-01T23:59:59.000Z

247

Heat exchanger efficiently operable alternatively as evaporator or condenser  

DOE Patents [OSTI]

A heat exchanger adapted for efficient operation alternatively as evaporator or condenser and characterized by flexible outer tube having a plurality of inner conduits and check valves sealingly disposed within the outer tube and connected with respective inlet and outlet master flow conduits and configured so as to define a parallel flow path for a first fluid such as a refrigerant when flowed in one direction and to define a serpentine and series flow path for the first fluid when flowed in the opposite direction. The flexible outer tube has a heat exchange fluid, such as water, flowed therethrough by way of suitable inlet and outlet connections. The inner conduits and check valves form a package that is twistable so as to define a spiral annular flow path within the flexible outer tube for the heat exchange fluid. The inner conduits have thin walls of highly efficient heat transfer material for transferring heat between the first and second fluids. Also disclosed are specific materials and configurations.

Ecker, Amir L. (Dallas, TX)

1981-01-01T23:59:59.000Z

248

ACID EVAPORATION OF ULTIMA GOLD TM AB LIQUID SCINTILLATION COCKTAIL RESIDUE  

SciTech Connect (OSTI)

Prior analyses of samples from the F/H Lab solutions showed the presence of diisopropylnapthalene (DIN), a major component of Ultima Gold{trademark} AB liquid scintillation cocktail (LSC). These solutions are processed through H-Canyon Tank 10.5 and ultimately through the 17.8E evaporator. Similar solutions originated in SRNL streams sent to the same H Canyon tanks. This study examined whether the presence of these organics poses a process-significant hazard for the evaporator. Evaporation and calorimetry testing of surrogate samples containing 2000 ppm of Ultima Gold{trademark} AB LSC in 8 M nitric acid have been completed. These experiments showed that although reactions between nitric acid and the organic components do occur, they do not appear to pose a significant hazard for runaway reactions or generation of energetic compounds in canyon evaporators. The amount of off-gas generated was relatively modest and appeared to be well within the venting capacity of the H-Canyon evaporators. A significant fraction of the organic components likely survives the evaporation process primarily as non-volatile components that are not expected to represent any new process concerns during downstream operations such as neutralization. Laboratory Waste solutions containing minor amounts of DIN can be safely received, stored, transferred, and processed through the canyon waste evaporator.

Kyser, E.; Fondeur, F.; Crump, S.

2011-12-21T23:59:59.000Z

249

Simulated Waste Testing Of Glycolate Impacts On The 2H-Evaporator System  

SciTech Connect (OSTI)

Glycolic acid is being studied as a total or partial replacement for formic acid in the Defense Waste Processing Facility (DWPF) feed preparation process. After implementation, the recycle stream from DWPF back to the high-level waste tank farm will contain soluble sodium glycolate. Most of the potential impacts of glycolate in the tank farm were addressed via a literature review, but several outstanding issues remained. This report documents the non-radioactive simulant tests impacts of glycolate on storage and evaporation of Savannah River Site high-level waste. The testing for which non-radioactive simulants could be used involved the following: the partitioning of glycolate into the evaporator condensate, the impacts of glycolate on metal solubility, and the impacts of glycolate on the formation and dissolution of sodium aluminosilicate scale within the evaporator. The following are among the conclusions from this work: Evaporator condensate did not contain appreciable amounts of glycolate anion. Of all tests, the highest glycolate concentration in the evaporator condensate was 0.38 mg/L. A significant portion of the tests had glycolate concentration in the condensate at less than the limit of quantification (0.1 mg/L). At ambient conditions, evaporator testing did not show significant effects of glycolate on the soluble components in the evaporator concentrates. Testing with sodalite solids and silicon containing solutions did not show significant effects of glycolate on sodium aluminosilicate formation or dissolution.

Martino, C. J.

2013-08-13T23:59:59.000Z

250

Analysis of the e-beam evaporation of titanium and Ti-6Al-4V  

SciTech Connect (OSTI)

An experimental and finite element analysis was performed for the electron-beam evaporation of Ti and Ti-6Al-4V from a bottom-feed system. The bulk evaporation rate was measured by feed consumption, and the pool elevation was held constant by adjusting the feed rate in a closed-loop control system. The instantaneous titanium and aluminum evaporation rates were determined by laser absorption in the vapor plume. Water temperature rises in cooling water circuits provided heat flows, and post-run cross sections revealed the location of the solidification zone. The MELT finite element code was applied to model the steady-state two-dimensional fluid flow and energy transport in the rod. There was good agreement between model and measured values of the heat flows and solidification boundaries for Ti. Measured bulk evaporation rates were similar for Ti and Ti-6-4 with greater variation observed for the Ti values. The model evaporation rates were higher than the measured values, but a similar linear dependence on e-beam power was observed in all cases. In a Ti-6-4 evaporation experiment with steady process conditions, laser absorption measurements showed much larger fluctuations in the evaporation rate for Al than Ti.

Westerberg, K.W.; Merier, T.C.; McClelland, M.A.; Braun, D.G.; Berzins, L.V.; Anklam, T.M.; Storer, J.

1998-02-11T23:59:59.000Z

251

Energy Savings in Direct Evaporative Cooling: real application in the Madrid metro and simulated application for offices in Sydney  

E-Print Network [OSTI]

Water evaporates spontaneously in contact with the air, absorbing around 680 W/(kg/h of evaporated water) from the air (1,053 BTU/lb.). Direct Evaporative Cooling (DEC) exploits this simple physical phenomenon to achieve high cooling capacities...

Simonetti, R.

2010-01-01T23:59:59.000Z

252

Field Performance of a Slimline Turbomist Evaporator under Southeastern U. S. Climate Conditions  

SciTech Connect (OSTI)

A recent study of evaporation technologies for treating F- and H-area groundwater contaminated with radionuclides and metals (Flach 2002) suggested that spray evaporation might be a viable alternative or supplemental technique for managing tritiated groundwater at the Mixed Waste Management Facility. The particular technology of interest in this study is the Slimline Manufacturing Ltd. Turbo-Mist Evaporator, which uses a powerful blower and high-pressure spray nozzles to propel a fine mist into the air at high air and water flowrates.

Sappington, F.C.

2003-12-15T23:59:59.000Z

253

Photoconductivity in reactively evaporated copper indium selenide thin films  

SciTech Connect (OSTI)

Copper indium selenide thin films of composition CuInSe{sub 2} with thickness of the order of 130 nm are deposited on glass substrate at a temperature of 423 5 K and pressure of 10{sup ?5} mbar using reactive evaporation, a variant of Gunther's three temperature method with high purity Copper (99.999%), Indium (99.999%) and Selenium (99.99%) as the elemental starting materials. X-ray diffraction (XRD) studies shows that the films are polycrystalline in nature having preferred orientation of grains along the (112) plane. The structural type of the film is found to be tetragonal with particle size of the order of 32 nm. The structural parameters such as lattice constant, particle size, dislocation density, number of crystallites per unit area and strain in the film are also evaluated. The surface morphology of CuInSe{sub 2} films are studied using 2D and 3D atomic force microscopy to estimate the grain size and surface roughness respectively. Analysis of the absorption spectrum of the film recorded using UV-Vis-NIR Spectrophotometer in the wavelength range from 2500 nm to cutoff revealed that the film possess a direct allowed transition with a band gap of 1.05 eV and a high value of absorption coefficient (?) of 10{sup 6} cm{sup ?1} at 570 nm. Photoconductivity at room temperature is measured after illuminating the film with an FSH lamp (82 V, 300 W). Optical absorption studies in conjunction with the good photoconductivity of the prepared p-type CuInSe{sub 2} thin films indicate its suitability in photovoltaic applications.

Urmila, K. S., E-mail: urmilaks7@gmail.com; Asokan, T. Namitha, E-mail: urmilaks7@gmail.com; Pradeep, B., E-mail: urmilaks7@gmail.com [Solid State Physics Laboratory, Cochin University of Science and Technology, Kochi, Kerala (India); Jacob, Rajani; Philip, Rachel Reena [Thin Film Research Laboratory, Union Christian College, Aluva, Kerala (India)

2014-01-28T23:59:59.000Z

254

An evaporation estimation method based on the coupled 2-D turbulent heat and vapor transport equations  

E-Print Network [OSTI]

equations Jozsef Szilagyi1,2 and Janos Jozsa1 Received 14 July 2008; revised 4 December 2008; accepted 7 temperature data. Citation: Szilagyi, J., and J. Jozsa (2009), An evaporation estimation method based

Szilagyi, Jozsef

255

E-Print Network 3.0 - accretion thermal evaporation Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

of air and diffusivity of water vapor, respectively. Note that Pced... . Evaporation of rainwater and depositional growth of snow (P,ed) the 0C ... Source: Zhang, Da-Lin -...

256

Procedure for Applying an Open-Cycle Heat Pump to An Existing Evaporator  

E-Print Network [OSTI]

An open-cycle heat pump, or mechanical vapor compression (MVC) system, is often an attractive technique for increasing the energy efficiency of an evaporator. With proper design, an MVC system is capable of dramatic cost savings when retrofitted...

Wagner, J. R.; Brush, F. C.

1984-01-01T23:59:59.000Z

257

Experimental Study of the Circulation Air Volume of Recirculation Evaporative Cooling  

E-Print Network [OSTI]

This paper introduces the technology of re-circulation evaporative cooling (REC), which uses a portion of supply air as secondary air to make cool water used to indirectly cool outside air through a heat exchanger. The circulation volume...

Xiong, J.; Liu, Z.; Wang, C.; Chen, G.

2006-01-01T23:59:59.000Z

258

An experimental study on new egg-crate type evaporators in domestic refrigerators and freezers  

SciTech Connect (OSTI)

This paper presents experimental results of the heat transfer performance of new egg-crate type evaporators that are becoming popular in vapor compression cycle-based modern refrigerators and freezers. These forced flow, multiple finned evaporators are preferred in the local industry over the older roll-bonded designs due to efficiency and cost considerations. Extensive testing was done, and experimental data were gathered on evaporators of three different sizes at three airflow rates using a closed-loop test rig built for the purpose. This has led to the development of a novel approach of measuring low air velocities as encountered in domestic refrigerators. A correlation has been developed for the heat transfer performance of these evaporators following the j-Colburn factor analysis. The correlation relates the j-Colburn factor, a nondimensional heat transfer grouping of the Nusselt number, Reynolds number, and Prandtl number to the Reynolds number and finning factor.

Bansal, P.K. [Univ. of Auckland (New Zealand). Dept. of Mechanical Engineering; Neuren, O.S. van [OPUS International Consultants, Ltd., Auckland (New Zealand)

1998-12-31T23:59:59.000Z

259

A feasibility study of internal evaporative cooling for proton exchange membrane fuel cells  

E-Print Network [OSTI]

An investigation was conducted to determine the feasibility of using the technique of ultrasonic nebulization of water into the anode gas stream for evaporative cooling of a Proton Exchange Membrane (PEM) fuel cell. The basic concept of this form...

Snyder, Loren E

2006-04-12T23:59:59.000Z

260

arXiv:1408.2487v2[physics.ao-ph]22Aug2014 Ising model for melt ponds on Arctic sea ice  

E-Print Network [OSTI]

arXiv:1408.2487v2[physics.ao-ph]22Aug2014 Ising model for melt ponds on Arctic sea ice Yi-Ping Ma,1, USA The albedo of melting Arctic sea ice, a key parameter in climate modeling, is determined by pools of water on the ice surface. Recent observations show an onset of pond complexity at a critical area

Golden, Kenneth M.

Note: This page contains sample records for the topic "lined evaporation pond" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Radiological Control of Water in Reactor Pond of MR Reactor in NRC 'Kurchatov Institute', During Dismantling Work - 13462  

SciTech Connect (OSTI)

The analysis of the activity and radionuclide composition of water from the MR reactor pond for ?,?,?-ray radionuclides was made. To solve this problem we use a wide range of laboratory equipment: gamma spectrometric complex, beta spectrometric complex, vacuum alpha spectrometer, and spectrometric complex with liquid scintillator. The water from MR reactor pond contains: Cs-137 (2,6*10{sup 2} Bq/g), Co-60(1,8 Bq/g), Sr-90 (1,0*10{sup 2} Bq/g), H-3 (7,0*10{sup 3} Bq/g), and components of nuclear fuel (U-232,U-234,U-235,U-236,U-238). Therefore the cleaning water from radioactivity waste occurs to be quite a complicated radiochemical task. (authors)

Stepanov, Alexey; Simirsky, Yury; Semin, Ilya; Volkovich, Anatoly; Ivanov, Oleg [National Research Center 'Kurchatov Institute', Moscow (Russian Federation)] [National Research Center 'Kurchatov Institute', Moscow (Russian Federation)

2013-07-01T23:59:59.000Z

262

LITERATURE REVIEW ON IMPACT OF GLYCOLATE ON THE 2H EVAPORATOR AND THE EFFLUENT TREATMENT FACILITY  

SciTech Connect (OSTI)

Glycolic acid (GA) is being studied as an alternate reductant in the Defense Waste Processing Facility (DWPF) feed preparation process. It will either be a total or partial replacement for the formic acid that is currently used. A literature review has been conducted on the impact of glycolate on two post-DWPF downstream systems - the 2H Evaporator system and the Effluent Treatment Facility (ETF). The DWPF recycle stream serves as a portion of the feed to the 2H Evaporator. Glycolate enters the evaporator system from the glycolate in the recycle stream. The overhead (i.e., condensed phase) from the 2H Evaporator serves as a portion of the feed to the ETF. The literature search revealed that virtually no impact is anticipated for the 2H Evaporator. Glycolate may help reduce scale formation in the evaporator due to its high complexing ability. The drawback of the solubilizing ability is the potential impact on the criticality analysis of the 2H Evaporator system. It is recommended that at least a theoretical evaluation to confirm the finding that no self-propagating violent reactions with nitrate/nitrites will occur should be performed. Similarly, identification of sources of ignition relevant to glycolate and/or update of the composite flammability analysis to reflect the effects from the glycolate additions for the 2H Evaporator system are in order. An evaluation of the 2H Evaporator criticality analysis is also needed. A determination of the amount or fraction of the glycolate in the evaporator overhead is critical to more accurately assess its impact on the ETF. Hence, use of predictive models like OLI Environmental Simulation Package Software (OLI/ESP) and/or testing are recommended for the determination of the glycolate concentration in the overhead. The impact on the ETF depends on the concentration of glycolate in the ETF feed. The impact is classified as minor for feed glycolate concentrations {le} 33 mg/L or 0.44 mM. The ETF unit operations that will have minor/major impacts are chlorination, pH adjustment, 1st mercury removal, organics removal, 2nd mercury removal, and ion exchange. For minor impacts, the general approach is to use historical process operations data/modeling software like OLI/ESP and/or monitoring/compiled process operations data to resolve any uncertainties with testing as a last resort. For major impacts (i.e., glycolate concentrations > 33 mg/L or 0.44 mM), testing is recommended. No impact is envisaged for the following ETF unit operations regardless of the glycolate concentration - filtration, reverse osmosis, ion exchange resin regeneration, and evaporation.

Adu-Wusu, K.

2012-05-10T23:59:59.000Z

263

Growth, survival, distribution, and population estimates of penaeid shrimp in fertilized and unfertilized brackish water ponds receiving thermal effluents  

E-Print Network [OSTI]

/kg) and per pound (()/lb), and the number or weight of miscellaneous organisms (misc. organ. ) collected at harvest, of white and brown shrimp Mean growth per day and food conversion of white shrimp between samples. F designates fertilized ponds... natural foods over a wide variety of supplemental feeds. A large variety of organic and inorganic fertilizers have been applied at different rates in shrimp culture operations to enhance the natural productivity of the system. The most inexpensive...

Furness, Gary Neal

1978-01-01T23:59:59.000Z

264

The microbial flora of pond-reared shrimp (Penaeus stylirostris, P. setiferus, P. vannamei, and Macrobrachium rosenbergii)  

E-Print Network [OSTI]

was reported by Margaret Green (10e15i16) who studied the effect of methods of catching and handling shrimp aboard fishing vessels on the microbial flora. . According to these reports, the microbial counts of freshly harvested shrimp are usually...). Water was supplied directly from the Laguna lNadre to each pond. The nursery -Nueces-; '%. CORPUS::-':. " ::. CHRISTI::. , '. . . . -Corpus Christi. :-. : ?:- = - Bay. = =, 'l:", . ;, NORTH CENTRAL POWER k LI GHT COMPANY ' S BARNEY M. DAVIS...

Christopher, Frank Mitchell

1976-01-01T23:59:59.000Z

265

Area 6 Decontamination Pond Corrective Action Unit 92 Post-Closure Inspection Annual Report for the Period January 2000-December 2000  

SciTech Connect (OSTI)

The Area 6 Decontamination Pond, Corrective Action Unit 92, was closed in accordance with the Resource Conservation and Recovery Act (RCRA) Part B Operational Permit (Nevada Division of Environmental Protection [NDEP, 1995]) and the Federal Facility Agreement and Consent Order (NDEP, 1996) on May 11, 1999. Historically the Decontamination Pond was used for the disposal of partially treated liquid effluent discharged from the Decontamination Facility (Building 6-05) and the Industrial Laundry (Building 6-07) (U.S. Department of Energy, Nevada Operations Office [DOE/NV], 1996). The Decontamination Pond was constructed and became operational in 1979. Releases of RCRA-regulated hazardous waste or hazardous waste constituents have not been discharged to the Decontamination Pond since 1988 (DOE/NV, 1996). The pipe connecting the Decontamination Pond and Decontamination Facility and Industrial Laundry were cut and sealed at the Decontamination Pad Oil/Water Separator in 1992. The Decontamination Pond was closed in place by installing a RCRA cover. Fencing was installed around the periphery to prevent accidental damage to the cover. Post-closure monitoring at the site consists of quarterly inspections of the RCRA cover and fencing, and a subsidence survey. Additional inspections are conducted if: Precipitation occurs in excess of 1.28 centimeters (cm) (0.50 inches [in]) in a 24-hour period, or An earthquake occurs with a magnitude exceeding 4.5 on the Richter scale within 100 kilometers (km) (62 miles [mi]) of the closure.

J. L. Traynor

2001-03-01T23:59:59.000Z

266

Experimental and numerical study of e-beam evaporation of titanium  

SciTech Connect (OSTI)

An experimental and numerical study is performed for the electron-beam evaporation of pure titanium from a bottom fed vapor source. In the experiments, an electron beam operating in the nominal range of 30-40 [kW] was used to evaporate metal from the top of a 3 [in] diameter rod. Variations were made in the e-beam power, sweep pattern, and sweep frequency, and the total evaporation rate was measured from feed consumption and laser absorption. The solid-pool interface was obtained from metallographic cross sections of the metal rod. A two-dimensional finite element model was developed for the melt which includes the effect of fluid flow and energy transport in the pool and conduction in the solid. The deformation of the liquid-vapor and solid-liquid interfaces are tracked using a mesh which stretches along spines parallel to the axis of the rod. For the cases considered, high evaporative fluxes and vapor pressures generate significant depressions in the top surface of the pool. Predicted and measured evaporation rates are in good agreement for moderate evaporation fluxes, but discrepancies are larger for the case involving the highest flux and deepest depression.

McClelland, M.A.; Westerberg, K.W.; Meier, T.C. [Lawrence Livermore National Lab., CA (United States)] [and others

1996-12-31T23:59:59.000Z

267

Experimental and numerical study of E-beam evaporation of titanium  

SciTech Connect (OSTI)

An experimental and numerical study is performed for the electron- beam evaporation of pure titanium from a bottom fed vapor source. In the experiments, an electron beam operating in the nominal range of 30-40 [kW] was used to evaporate metal from the top of a 3 inch diameter rod. Variations were made in the e-beam power, sweep pattern, and sweep frequency, and the total evaporation rate was measured from feed consumption and laser absorption. The solid-pool interface was obtained from metallographic cross sections of the metal rod. A two-dimensional finite element model was developed for the melt which includes the effect of fluid flow and energy transport in the pool and conduction in the solid. The deformation of the liquid-vapor and solid-liquid interfaces are tracked using a mesh which stretches along spines parallel to the axis of the rod. For the cases considered, high evaporative fluxes and vapor pressures generate significant depressions in the top surface of the pool. Predicted and measured evaporation rates are in good agreement for moderate evaporation fluxes, but discrepancies are larger for the case involving the highest flux and deepest depression.

McClelland, M.A.; Westerberg, K.W.; Meier, T.C.; Braun, D.G.; Berrins, L.V.; Anklam, T.M. Storer, J.

1997-11-26T23:59:59.000Z

268

Projected Benefits of New Residential Evaporative Cooling Systems: Progress Report #2  

SciTech Connect (OSTI)

The use of conventional evaporative cooling has rapidly declined in the United States despite the fact that it has high potential for energy savings in dry climates. Evaporative systems are very competitive in terms of first cost and provide significant reductions in operating energy use, as well as peak-load reduction benefits. Significant market barriers still remain and can be addressed through improved systems integration. This report investigates the first of these approaches, exploring innovative components. The U.S. Department of Energy (DOE) Building America research teams are investigating the use of two promising new pieces of residential cooling equipment that employ evaporative cooling as a part of their system design. The OASys unit, which is a combination of direct and indirect evaporative cooling stages developed by Davis Energy Group (DEG) and manufactured by Speakman CRS, is used to ultimately provide outside air to the living space. The outdoor air provided is indirectly and directly evaporatively cooled in two stages to a condition that can be below the wet-bulb (wb) temperature of the outside air, thus outperforming a conventional single-stage direct evaporative cooler.

Kutscher, C.; Eastment, M.; Hancock, E.; Reeves, P.

2006-10-01T23:59:59.000Z

269

Processing of Oak Ridge B&C pond sludge surrogate in the transportable vitrification system  

SciTech Connect (OSTI)

The Transportable Vitrification System (TVS) developed at the Savannah River Site is designed to process low-level and mixed radioactive wastes into a stable glass product. The TVS consists of a feed preparation and delivery system, a joule-heated melter, and an offgas treatment system. Surrogate Oak Ridge Reservation (ORR) B&C pond sludge was treated in a demonstration of the TVS system at Clemson University and at ORR. After initial tests with soda-lime-silica (SLS) feed, three melter volumes of glass were produced from the surrogate feed. A forthcoming report will describe glass characterization; and melter feeding, operation, and glass pouring. Melter operations described will include slurry characterization and feeding, factors affecting feed melt rates, glass pouring and pour rate constraints, and melter operating temperatures. Residence time modeling of the melter will also be discussed. Characterization of glass; including composition, predicted liquidity and viscosity, Toxic Characteristic Leaching Procedure (TCLP), and devitrification will be covered. Devitrification was a concern in glass container tests and was found to be mostly dependent on the cooling rate. Crucible tests indicated that melter shutdown with glass containing Fe and Li was also a devitrification concern, so the melter was flushed with SLS glass before cooldown.

Zamecnik, J.R.; Young, S.R.; Peeler, D.K.; Smith, M.E.

1997-04-16T23:59:59.000Z

270

Plasma-mediated surface evaporation of an aluminium target in vacuum under UV laser irradiation  

SciTech Connect (OSTI)

Mathematical simulation is employed to investigate the dynamics of evaporation and condensation on the surface of a metal target under the conditions of plasma production in the vaporised material exposed to the 0.248-{mu}m UV radiation of a KrF laser with the intensity G{sub 0}= 2x10{sup 8}-10{sup 9} W cm{sup -2}, and a pulse duration {tau}= 20 ns. A transient two-dimensional mathematical model is used, which includes, for the condensed medium, the heat conduction equation with the Stefan boundary condition and additional kinetic conditions at the evaporation surface and, for the vapour, the equations of radiative gas dynamics and laser radiation transfer supplemented with tabular data for the parameters of the equations of state and absorption coefficients. The target evaporation in vacuum induced by the UV radiation was found to occur during the laser pulse and is divided into two characteristic stages: initial evaporation with a sound velocity and subsonic evaporation after the plasma production. At the subsonic evaporation stage, one part of the laser radiation passes through the plasma and is absorbed by the target surface and another part is absorbed in a thin plasma layer near the surface to produce a high pressure, which significantly moderates the vapour ejection. After completion of the pulse, a part of the vaporised material is condensed on the surface, both in the evaporation region and some distance away from it due to the lateral expansion of the plasma cloud. (interaction of laser radiation with matter. laser plasma)

Mazhukin, V I; Nosov, V V [Institute of Mathematical Modelling, Russian Academy of Sciences, Moscow (Russian Federation)

2005-05-31T23:59:59.000Z

271

Laboratory studies of 2H evaporator scale dissolution in dilute nitric acid  

SciTech Connect (OSTI)

The rate of 2H evaporator scale solids dissolution in dilute nitric acid has been experimentally evaluated under laboratory conditions in the SRNL shielded cells. The 2H scale sample used for the dissolution study came from the bottom of the evaporator cone section and the wall section of the evaporator cone. The accumulation rate of aluminum and silicon, assumed to be the two principal elemental constituents of the 2H evaporator scale aluminosilicate mineral, were monitored in solution. Aluminum and silicon concentration changes, with heating time at a constant oven temperature of 90 deg C, were used to ascertain the extent of dissolution of the 2H evaporator scale mineral. The 2H evaporator scale solids, assumed to be composed of mostly aluminosilicate mineral, readily dissolves in 1.5 and 1.25 M dilute nitric acid solutions yielding principal elemental components of aluminum and silicon in solution. The 2H scale dissolution rate constant, based on aluminum accumulation in 1.5 and 1.25 M dilute nitric acid solution are, respectively, 9.21E-04 6.39E-04 min{sup -1} and 1.07E-03 7.51E-05 min{sup -1}. Silicon accumulation rate in solution does track the aluminum accumulation profile during the first few minutes of scale dissolution. It however diverges towards the end of the scale dissolution. This divergence therefore means the aluminum-to-silicon ratio in the first phase of the scale dissolution (non-steady state conditions) is different from the ratio towards the end of the scale dissolution. Possible causes of this change in silicon accumulation in solution as the scale dissolution progresses may include silicon precipitation from solution or the 2H evaporator scale is a heterogeneous mixture of aluminosilicate minerals with several impurities. The average half-life for the decomposition of the 2H evaporator scale mineral in 1.5 M nitric acid is 12.5 hours, while the half-life for the decomposition of the 2H evaporator scale in 1.25 M nitric acid is 10.8 hours. Based on averaging the two half-lives from the 2H scale acid dissolution in 1.25 and 1.5 M nitric acid solutions, a reasonable half-live for the dissolution of 2H scales in dilute nitric acid is 11.7 1.3 hours. The plant operational time for chemically cleaning (soaking) the 2H evaporator with dilute nitric acid is 32 hours. It therefore may require about 3 half-lives or less to completely dissolve most of the scales in the Evaporator pot which come into contact with the dilute nitric acid solution. On a mass basis, the Al-to-Si ratio for the scale dissolution in 1.5 M nitric acid averaged 1.30 0.20 and averaged 1.18 0.10 for the 2H scale dissolution in 1.25 M nitric acid. These aluminum-to-silicon ratios are in fairly good agreement with ratios from previous studies. Therefore, there is still more aluminum in the 2H evaporator scales than silicon which implies that there are no significant changes in scale properties which will exclude nitric acid as a viable protic solvent for aluminosilicate scale buildup dissolution from the 2H evaporator. Overall, the monitoring of the scale decomposition reaction in 1.25 and 1.5 M nitric acid may be better ascertained through the determination of aluminum concentration in solution than monitoring silicon in solution. Silicon solution chemistry may lead to partial precipitating of silicon with time as the scale and acid solution is heated.

Oji, L.

2014-09-23T23:59:59.000Z

272

2010 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Sites Advanced Test Reactor Complex Cold Waste Pond  

SciTech Connect (OSTI)

This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (#LA 000161 01, Modification B), for the wastewater land application site at the Idaho National Laboratory Sites Advanced Test Reactor Complex Cold Waste Pond from November 1, 2009 through October 31, 2010. The report contains the following information: Facility and system description Permit required effluent monitoring data and loading rates Groundwater monitoring data Status of compliance activities Discussion of the facilitys environmental impacts During the 2010 permit year, approximately 164 million gallons of wastewater were discharged to the Cold Waste Pond. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest near the Cold Waste Pond and decrease rapidly as the distance from the Cold Waste Pond increases. Although concentrations of sulfate and total dissolved solids are elevated near the Cold Waste Pond, both parameters were below the Ground Water Quality Rule Secondary Constituent Standards in the down gradient monitoring wells.

mike lewis

2011-02-01T23:59:59.000Z

273

2013 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Sites Advanced Test Reactor Complex Cold Waste Pond  

SciTech Connect (OSTI)

This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (#LA 000161 01, Modification B), for the wastewater land application site at the Idaho National Laboratory Sites Advanced Test Reactor Complex Cold Waste Pond from November 1, 2012October 31, 2013. The report contains the following information: Facility and system description Permit required effluent monitoring data and loading rates Groundwater monitoring data Status of compliance activities Noncompliance issues Discussion of the facilitys environmental impacts. During the 2013 permit year, approximately 238 million gallons of wastewater was discharged to the Cold Waste Pond. This is well below the maximum annual permit limit of 375 million gallons. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest near the Cold Waste Pond and decrease rapidly as the distance from the Cold Waste Pond increases. Although concentrations of sulfate and total dissolved solids are elevated near the Cold Waste Pond, both parameters are below the Ground Water Quality Rule Secondary Constituent Standards in the down gradient monitoring wells.

Mike Lewis

2014-02-01T23:59:59.000Z

274

Series Transmission Line Transformer  

DOE Patents [OSTI]

A series transmission line transformer is set forth which includes two or more of impedance matched sets of at least two transmissions lines such as shielded cables, connected in parallel at one end ans series at the other in a cascading fashion. The cables are wound about a magnetic core. The series transmission line transformer (STLT) which can provide for higher impedance ratios and bandwidths, which is scalable, and which is of simpler design and construction.

Buckles, Robert A. (Livermore, CA); Booth, Rex (Livermore, CA); Yen, Boris T. (El Cerrito, CA)

2004-06-29T23:59:59.000Z

275

Analytical services: 222-S characterization of 242-A Evaporator Slurry, Campaign 94-1. Addendum 1A  

SciTech Connect (OSTI)

During the 242-A Evaporator`s 94-1 campaign, five process samples were collected from the slurry stream for waste characterization. The five samples were collected over a 36 day time span, respectively on May 4, May 9, May 16, May 23, and June 9, 1994. Sample collections were performed per the protocol described in 242-A Evaporator Waste Analysis Plan, WHC-SD-WM-EV-060, Rev. 3 and in 242-A Evaporator Quality Assurance Project Plan, WHC-SD-WM-QAPP-009, Rev. 0. Slurry waste was characterized chemically and radiochemically by the Westinghouse Hanford Company, 222-S Laboratory as directed.

Not Available

1994-09-13T23:59:59.000Z

276

Laboratory Evaporation Testing Of Hanford Waste Treatment Plant Low Activity Waste Off-Gas Condensate Simulant  

SciTech Connect (OSTI)

The Hanford Waste Treatment and Immobilization Plant (WTP) Low Activity Waste (LAW) vitrification facility will generate an aqueous condensate recycle stream, LAW Off-Gas Condensate, from the off-gas system. The baseline plan for disposition of this stream is to send it to the WTP Pretreatment Facility, where it will be blended with LAW, concentrated by evaporation and recycled to the LAW vitrification facility again. Alternate disposition of this stream would eliminate recycling of problematic components, and would enable de-coupled operation of the LAW melter and the Pretreatment Facilities. Eliminating this stream from recycling within WTP would also decrease the LAW vitrification mission duration and quantity of canistered glass waste forms. This LAW Off-Gas Condensate stream contains components that are volatile at melter temperatures and are problematic for the glass waste form. Because this stream recycles within WTP, these components accumulate in the Condensate stream, exacerbating their impact on the number of LAW glass containers that must be produced. Approximately 32% of the sodium in Supplemental LAW comes from glass formers used to make the extra glass to dilute the halides to be within acceptable concentration ranges in the LAW glass. Diverting the stream reduces the halides in the recycled Condensate and is a key outcome of this work. Additionally, under possible scenarios where the LAW vitrification facility commences operation prior to the WTP Pretreatment facility, identifying a disposition path becomes vitally important. This task examines the impact of potential future disposition of this stream in the Hanford tank farms, and investigates auxiliary evaporation to enable another disposition path. Unless an auxiliary evaporator is used, returning the stream to the tank farms would require evaporation in the 242-A evaporator. This stream is expected to be unusual because it will be very high in corrosive species that are volatile in the melter (chloride, fluoride, sulfur), will have high ammonia, and will contain carryover particulates of glass-former chemicals. These species have potential to cause corrosion of tanks and equipment, precipitation of solids, release of ammonia gas vapors, and scale in the tank farm evaporator. Routing this stream to the tank farms does not permanently divert it from recycling into the WTP, only temporarily stores it prior to reprocessing. Testing is normally performed to demonstrate acceptable conditions and limits for these compounds in wastes sent to the tank farms. The primary parameter of this phase of the test program was measuring the formation of solids during evaporation in order to assess the compatibility of the stream with the evaporator and transfer and storage equipment. The origin of this LAW Off-Gas Condensate stream will be the liquids from the Submerged Bed Scrubber (SBS) and the Wet Electrostatic Precipitator (WESP) from the LAW facility melter offgas system. The stream is expected to be a dilute salt solution with near neutral pH, and will likely contain some insoluble solids from melter carryover. The soluble components are expected to be mostly sodium and ammonium salts of nitrate, chloride, and fluoride. This stream has not been generated yet, and, thus, the composition will not be available until the WTP begins operation, but a simulant has been produced based on models, calculations, and comparison with pilot-scale tests. This report discusses results of evaporation testing of the simulant. Two conditions were tested, one with the simulant at near neutral pH, and a second at alkaline pH. The neutral pH test is comparable to the conditions in the Hanford Effluent Treatment Facility (ETF) evaporator, although that evaporator operates at near atmospheric pressure and tests were done under vacuum. For the alkaline test, the target pH was based on the tank farm corrosion control program requirements, and the test protocol and equipment was comparable to that used for routine evaluation of feed compatibility studies for the 242-A evaporator. One of the

Adamson, Duane J.; Nash, Charles A.; McCabe, Daniel J.; Crawford, Charles L.; Wilmarth, William R.

2014-01-27T23:59:59.000Z

277

Electric Transmission Lines (Nebraska)  

Broader source: Energy.gov [DOE]

The Public Service Commission has jurisdiction over all electricity transmission lines crossing over or under railroad tracks at public highway crossings. This section contains general regulations...

278

Habitat-related activities and body mass of wintering redhead ducks on coastal ponds in south Texas  

E-Print Network [OSTI]

and content by: Milton W. Wailer (Co-Chair of Committee) William H. Riel, Jr. (Co-Chair of Committee) Nova J. Silvy (Member) James W. Webb, Jr. (Member) D id J. Schmid y (Head of Depart nt) August 1991 ABSTRACT Habitat-Related Activities and Body Mass... of Wintering Redhead Ducks on Coastal Ponds in South Texas. (August 1991) Joseph Lane Moore, B. S. F. R. , University of Georgia, Athens Co-Chairs of Advisory Committee: Dr. Milton W. Weller William H. Riel, Jr. Time-activity budgets of individually...

Moore, Joseph Lane

1991-01-01T23:59:59.000Z

279

Resource Conservation and Recovery Act industrial site environmental restoration site characterization report - area 6 steam cleaning effluent ponds  

SciTech Connect (OSTI)

The Area 6 North and South Steam Cleaning Effluent Ponds (SCEPs) are historic disposal units located at the Nevada Test Site (NTS) in Nye County, Nevada. The NTS is operated by the U.S. Department of Energy, Nevada Operations Office (DOE/NV) which has been required by the Nevada Division of Environmental Protection (NDEP) to characterize the site under the requirements of the Resource Conservation and Recovery Act (RCRA) Part B Permit for the NTS and Title 40 Code of Federal Regulations, Part 265.

NONE

1996-09-01T23:59:59.000Z

280

Environmental Assessment and Finding of No Significant Impact: Pond B Dam Repair Project at the Savannah River Site  

SciTech Connect (OSTI)

The Department of Energy (DOE) has prepared an environmental assessment (EA) (DOE/EA-1285) for the proposed repair of the Pond B dam at the Savannah River Site (SRS), located near Aiken, South Carolina. Based on the analyses in the EA, DOE has determined that the proposed action is not a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act of 1969 (NEPA). Therefore, the preparation of an environmental impact statement (EIS) is not required, and DOE is issuing this Finding of No Significant Impact (FONSI) and Floodplain Statement of Findings.

N /A

1999-09-27T23:59:59.000Z

Note: This page contains sample records for the topic "lined evaporation pond" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Spectral Lags of Gamma-Ray Bursts from Primordial Black Hole (PBH) Evaporations  

E-Print Network [OSTI]

Primordial Black Holes (PBHs), which may have been created in the early Universe, are predicted to be detectable by their Hawking radiation. PBHs with an initial mass of 5.0 * 10^14 g should be expiring today with a burst of high energy particles. Evaporating PBHs in the solar neighborhood are candidate Gamma-Ray Bursts (GRBs) progenitors. We propose spectral lag, which is the temporal delay between the high energy photon pulse and the low energy photon pulse, as a possible method to detect PBH evaporation events with the Fermi Gamma-ray Space Telescope Observatory.

T. N. Ukwatta; J. H. MacGibbon; W. C. Parke; K. S. Dhuga; A. Eskandarian; N. Gehrels; L. Maximon; D. C. Morris

2009-08-14T23:59:59.000Z

282

Star-planet magnetic interaction and evaporation of planetary atmospheres  

E-Print Network [OSTI]

Stars interact with their close-in planets through radiation, gravitation, and magnetic fields. We investigate the energy input to a planetary atmosphere by reconnection between stellar and planetary magnetic fields and compare it to the energy input of the extreme ultraviolet (EUV) radiation field of the star. We quantify the power released by magnetic reconnection at the boundary of the planetary magnetosphere that is conveyed to the atmosphere by accelerated electrons. We introduce simple models to evaluate the energy spectrum of the accelerated electrons and the energy dissipated in the atmospheric layers in the polar regions of the planet upon which they impinge. A simple transonic isothermal wind flow along field lines is considered to estimate the increase in mass loss rate in comparison with a planet irradiated only by the EUV flux of its host star. We find that energetic electrons can reach levels down to column densities of 10^{23}-10^{25} m^{-2}, comparable with or deeper than EUV photons, and incr...

Lanza, A F

2013-01-01T23:59:59.000Z

283

Geodesic Lines, . . . Covariant . . .  

E-Print Network [OSTI]

Geodesic Lines, . . . Covariant . . . Home Page Title Page Page 781 of 818 Go Back Full Screen Close Quit 14.11. Geodesic Lines, Local Gauss-Bonnet Theorem Geodesics play a very important role in surface theory and in dynamics. One of the main reasons why geodesics are so important

Gallier, Jean

284

Transmission Line Security Monitor  

ScienceCinema (OSTI)

The Transmission Line Security Monitor is a multi-sensor monitor that mounts directly on high-voltage transmission lines to detect, characterize and communicate terrorist activity, human tampering and threatening conditions around support towers. For more information about INL's critical infrastructure protection research, visit http://www.facebook.com/idahonationallaboratory.

None

2013-05-28T23:59:59.000Z

285

Post-closure permit application for the Upper East Fork Poplar Creek hydrogeologic regime at the Y-12 Plant: New Hope Pond and Eastern S-3 ponds plume. Revision 2  

SciTech Connect (OSTI)

The intent of this Post-Closure, Permit Application (PCPA) is to satisfy the post-closure permitting requirements of the Tennessee Department of Environment and Conservation (TDEC) Rule 1200-1-11. This application is for the entire Upper East Fork Poplar Creek Hydrogeologic Regime (East Fork Regime), which is within the Bear Creek Valley (BCV). This PCPA has been prepared to include the entire East Fork Regime because, although there are numerous contaminant sources within the regime, the contaminant plumes throughout the East Fork Regime have coalesced and can no longer be distinguished as separate plumes. This PCPA focuses on two recognized Resource Conservation and Recovery Act (RCRA) interim status units: New Hope Pond (NHP) and the eastern S-3 Ponds plume. This PCPA presents data from groundwater assessment monitoring throughout the regime, performed since 1986. Using this data, this PCPA demonstrates that NHP is not a statistically discernible source of groundwater contaminants and that sites upgradient of NHP are the likely sources of groundwater contamination seen in the NHP vicinity. As such, this PCPA proposes a detection monitoring program to replace the current assessment monitoring program for NHP.

NONE

1995-02-01T23:59:59.000Z

286

Brackish water pond polyculture of estuarine fishes in power plant thermal effluent and their use as biological monitors of water quality  

E-Print Network [OSTI]

-Old Striped Mullet, 2-Year-Old Atlantic Croaker, 1-Year-Old Southern Flounder Miscellaneous Organisms Unstocked-Unfiltered Ponds. . . . . . . . . . . . Stocked Ponds. Selected Metals and Pesticides Analyses. . . . 21 21 22 23 26 33 40 43 43 46... Station consists of three 750 megawatt units. Name-plate ratings specify maximum cooling water requirements of 76, 840 m /hr. However, ac- 3 tual pumping rates exceed the name-plate ratings by 2% for unit 1, 6% for unit 2, and less than 1% for unit 3...

Branch, Mark Roy

1977-01-01T23:59:59.000Z

287

Effect of feed levels and stocking density on growth and survival of Penaeus vannamei and Penaeus stylirostris stocked in pond cages  

E-Print Network [OSTI]

EFFECT OF FEED LEVELS AND STOCKING DENSITY ON GROWTH AND SURVIVAL OF F *I. ARD F ~tl' t STOCKED IN POND CAGES A thesis by JACK ROMAN LUSZCZYNSKI Submitted to the Graduate College of Texas A&M University in partial fulfillment... of the requirements for the degree of MASTER OF SCIENCE May 1987 Major subject: Wildlife and Fisheries Sciences EFFECT OF FEED LEVELS AND STOCKING DENSITY ON GROWTH AND nnnvlvAL QF pena ua v n m ' AFD p ~tl 'o t STOCKED IN POND CAGES A Thesis by JACK ROMAN...

Luszczynski, Jack Roman

1987-01-01T23:59:59.000Z

288

The culture of marine fish and their use as biological monitors of water quality in ponds receiving heated discharge water from a power station  

E-Print Network [OSTI]

Map showing location of power plant snd research facilities. 12 Diagram showing research facilities. Ponds numbered 1 through 25 from west to east. Daily hydrological data for the intake canal (Janu- ary 23, 1973 ? March 5, 1974... pond was approximately 0. 1 ha in surface area, 82. 3 m long, TS 00 SS 20 COOI INC IAXE 29 ~ 5 INTAKE AREA RESEARCH I CILITIES DISCHAROE CANAL POWER PLANT CEOAR RATOU TRINITY SAY ~ 0 0% M 0 0 OO . ~, OO 0 0 +I 0 Oll CLI 0 HLI 08 ~ '0...

Linder, Donald Ray

1974-01-01T23:59:59.000Z

289

The growth and survival of brown shrimp (Penaeus aztecus) and blue crabs (Callinectes sapidus) in ponds receiving heated bay water from an electric power plant  

E-Print Network [OSTI]

, and John We lch. This research was funded by IIouston Lighting and Pow, . r Com- pany through a grani to the Texas Agricultural L'xperiment Station (Project 1869) . TABLE OF CONTENTS Pacae IN TRODU C TIO N PRESENT STATUS OF THE PROBLEM Summary... . t tlf' t' d C~ ~Ih t populations in shrimp ponds 83 V t' al t df' t' d~C? ' l h . t populations in crab ponds 84 LIST 0 F F I GU RES Number P acre Map showing location of research facilities. Insert sl'ows Galveston Bay system on Texas Gulf coast...

Gould, Robert Andrew

1973-01-01T23:59:59.000Z

290

Microcrustaceans (Branchiopoda and Copepoda) of Wetland Ponds and Impoundments on the Savannah River Site, Aiken, South Carolina  

SciTech Connect (OSTI)

The United States Department of Energy's Savannah River Site (SRS) in Aiken, Allendale, and Barnwell Counties, South Carolina, contains an abundance of freshwater wetlands and impoundments. Four large impoundments, as well as several small, abandoned farm and mill ponds, and about 400 Carolina bays and other small, isolated depression wetland ponds are located within the 893 km2 area of the SRS. Crustaceans of the orders Branchiopoda and Copepoda are nearly ubiquitous in these water bodies. Although small in size, these organisms are often very abundant. They consequently play an important trophic role in freshwater food webs supporting fish, larval salamanders, larval insects, and numerous other animals, aquatic and terrestrial. This report provides an introduction to the free-living microcrustaceans of lentic water bodies on the SRS and a comprehensive list of species known to occur there. Occurrence patterns are summarized from three extensive survey studies, supplemented with other published and unpublished records. In lieu of a key, we provide a guide to taxonomic resources and notes on undescribed species. Taxa covered include the orders Cladocera, Anostraca, Laevicaudata, and Spinicaudata of the Subclass Branchiopoda and the Superorders Calanoida and Cyclopoida of Subclass Copepoda. Microcrustaceans of the Superorder Harpacticoida of the Subclass Copepoda and Subclass Ostracoda are also often present in lentic water bodies. They are excluded from this report because they have not received much study at the species level on the SRS.

Adrienne E. DeBiase; Barbara E. Taylor

2005-09-21T23:59:59.000Z

291

Resource Conservation and Recovery Act corrective measures study: Area 6 decontamination pond facility, corrective action unit no. 92  

SciTech Connect (OSTI)

Corrective Action Unit (CAU) No. 92, the Area 6 Decontamination Pond Facility (DPF), is an historic disposal unit located at the Nevada Test Site (NTS) in Nye County, Nevada (Figures 1 - 1, 1-2, and 1-3). The NTS is operated by the U.S. Department of Energy, Nevada Operations Office (DOE/NV), which has been required by the Nevada Division of Environmental Protection (NDEP) to characterize the DPF under the requirements of the Resource Conservation and Recovery Act (RCRA) Part A Permit (NDEP, 1995) for the NTS and Title 40 Code of Federal Regulations (CFR) Part 265 (1996c). The DPF is prioritized in the Federal Facility Agreement and Consent Order (FFACO, 1996) but is governed by the permit. The DPF was characterized through sampling events in 1994, 1996, and 1997. The results of these sampling events are contained in the Final Resource Conservation and Recovery Act Industrial Site Environmental Restoration Site Characterization Report, Area 6 Decontamination Pond Facility, Revision I (DOE/NV, 1997). This Corrective Measures Study (CMS) for the Area 6 DPF has been prepared for the DOE/NV`s Environmental Restoration Project. The CMS has been developed to support the preparation of a Closure Plan for the DPF. Because of the complexities of the contamination and regulatory issues associated with the DPF, DOE/NV determined a CMS would be beneficial to the evaluation and selection of a closure alternative.

NONE

1997-10-01T23:59:59.000Z

292

Author's personal copy Mixed crystalline films of co-evaporated hydrogen-and  

E-Print Network [OSTI]

Author's personal copy Mixed crystalline films of co-evaporated hydrogen- and fluorine-terminated phthalocyanines and their application in photovoltaic devices Andreas Opitz a,*, Bernhard Ecker a , Julia Wagner Photovoltaic cells a b s t r a c t Blends of organic electron and hole conductive materials are widely used

Schreiber, Frank

293

Charge-pumping in a synthetic leaf for harvesting energy from evaporation-driven flows  

E-Print Network [OSTI]

Charge-pumping in a synthetic leaf for harvesting energy from evaporation-driven flows Ruba T storage capacitor by 2­5 V. We provide estimates of power density, energy density, and scavenging. When the gas phase around the plant is at a lower water potential than the saturated soil, water

Maharbiz, Michel

294

O of water vapour, evapotranspiration and the sites of leaf water evaporation in a soybean canopy  

E-Print Network [OSTI]

, leaving surface water pools more enriched in the heavy isotopo- logues (H2 18 O). The enrichment is linkedd18 O of water vapour, evapotranspiration and the sites of leaf water evaporation in a soybean Department of Soil, Water, and Climate, University of Minnesota, St. Paul, MN 55108, USA and 3 Agricultural

Lee, Xuhui

295

Upscaling of soil hydraulic properties for steady state evaporation and infiltration  

E-Print Network [OSTI]

Upscaling of soil hydraulic properties for steady state evaporation and infiltration Jianting Zhu September 2002. [1] Estimation of effective/average soil hydraulic properties for large land areas and guidelines for upscaling soil hydraulic properties in an areally heterogeneous field. In this study, we

Mohanty, Binayak P.

296

The evaporation rate, free energy, and entropy of amorphous water Robin J. Speedy  

E-Print Network [OSTI]

The evaporation rate, free energy, and entropy of amorphous water at 150 K Robin J. Speedy can be interpreted as giving a measure of their free energy difference, i a G 150 K 1100 100 J of amorphous water (a) and ice (i) near 150 K and suppose that their ratio gives a measure of their free energy

297

Optimal design of a micro-orifice for constant evaporator superheat in a small cooler  

E-Print Network [OSTI]

of the orifice, the aspect ratio between length and diameter, the entrance angle to the orifice, and the surface through the condenser (B) with a heat pipe. Then, the orifice (C) changes the liquid to two-phase vapor device is required for the isenthalpic process between the condenser and the evaporator. The expansion

Kim, Jongwon

298

Complementary relationship of evaporation and the mean annual water-energy balance  

E-Print Network [OSTI]

Complementary relationship of evaporation and the mean annual water-energy balance Jozsef Szilagyi1 and the mean annual water-energy balance, Water Resour. Res., 45, W09201, doi:10.1029/2009WR008129. [2] Gerrits balance necessarily operates at the catchment scale, plus E0 depends predominantly on the available energy

Szilagyi, Jozsef

299

The Effect of Reduced Evaporator Air Flow on the Performance of a Residential Central Air Conditioner  

E-Print Network [OSTI]

This paper discusses the measured degradation in performance of a residential air conditioning system operating under reduced evaporator air flow. Experiments were conducted using a R-22 three-ton split-type cooling system with a short-tube orifice...

Palani, M.; O'Neal, D.; Haberl, J.

300

Optical Properties and Radiation-Enhanced Evaporation of Nanofluid Fuels Containing Carbon-Based Nanostructures  

E-Print Network [OSTI]

and thermal systems as an advanced heat-transfer fluid, e.g., advanced cooling of electronics systemsOptical Properties and Radiation-Enhanced Evaporation of Nanofluid Fuels Containing Carbon characteristics of nanofluid fuels with stable suspension of carbon-based nanostructures under radiation

Qiao, Li

Note: This page contains sample records for the topic "lined evaporation pond" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

On the inherent asymmetric nature of the complementary relationship of evaporation  

E-Print Network [OSTI]

), thus it took some time before his idea was put into practice by Brutsaert and Stricker [1979 be considered as the apparent potential evaporation. [4] In Brutsaert and Stricker's [1979] Advection is the Priestley-Taylor parameter. Employing the so-defined terms of (1), Brutsaert and Stricker [1979] assumed

Szilagyi, Jozsef

302

Results from evaporation tests to support the MWTF heat removal system design  

SciTech Connect (OSTI)

An experimental tests program was conducted to measure the evaporative heat removal from the surface of a tank of simulated waste. The results contained in this report constitute definition design data for the latest heat removal function of the MWTF primary ventilation system.

Crea, B.A.

1994-12-22T23:59:59.000Z

303

Gas exchange in terrestrial environments comes at the cost of evaporative water loss from respiratory surfaces.  

E-Print Network [OSTI]

3477 Gas exchange in terrestrial environments comes at the cost of evaporative water loss from of gas exchange, both within and among species (Lighton, 1998; Shelton and Appel, 2001; Chown, 2002). The classical pattern is that of discontinuous gas exchange, or discontinuous gas-exchange cycles (DGC; Lighton

Franz, Nico M.

304

Optimal design of a micro evaporator with lateral gaps Taijong Sung a  

E-Print Network [OSTI]

transfer coefficient (HTC) and it forms the starting point in developing miniaturized vapor­outlet condi- tions of the evaporator have a standard design of expansion valve and compressor and so the heat and Lee [7] studied the correlation in order to represent the heat transfer coefficients of the boiling

Kim, Jongwon

305

Atmospheric Environment 42 (2008) 30763086 Scavenging of soluble gases by evaporating and growing cloud  

E-Print Network [OSTI]

and condensation of a cloud droplet in the presence of soluble gases. It is assumed that gas absorption we performed numerical analysis of simultaneous heat and mass transfer during evaporation into account thermal effect of gas absorption. It was shown that nonlinear behavior of different parameters

Elperin, Tov

306

Under consideration for publication in J. Fluid Mech. 1 Evaporation and combustion  

E-Print Network [OSTI]

Under consideration for publication in J. Fluid Mech. 1 Evaporation and combustion of thin films the tendency to destabilize the planar interface, combustion acts to reduce this effect. In particular, when the heat release by combustion is substantial, all disturbances are obliterated, the film remains nearly

307

Improving Ice Cover and Evaporation Estimates Primary Investigator: Thomas E. Croley (Emeritus), Raymond Assel (Emeritus) -NOAA  

E-Print Network [OSTI]

Improving Ice Cover and Evaporation Estimates Primary Investigator: Thomas E. Croley (Emeritus. For example, ice cover is projected to be significantly less under global warming, air temperature higher, and precipitation greater (Lofgren, et al, in press). Improved long-range ice forecasts would be of interest

308

The energy saving potential of precooling incoming outdoor air by indirect evaporative cooling  

SciTech Connect (OSTI)

This paper investigates the energy saving potentials of using indirect evaporative coolers to precool incoming outdoor air as the first stage of a standard cooling system. For dry and moderately humid locations, either exhaust room air or outdoor air can be used as the secondary air to the indirect evaporative precooler with similar energy savings. Under these conditions, the use of outdoor air is recommended due to the simplicity in installing the duct system. For humid locations, the use of exhaust room air is recommended because the precooling capacity and energy savings will be greatly increased. For locations with short cooling seasons, the use of indirect evaporative coolers for precooling may not be worthwhile. The paper also gives some simplified indices for easily predicting the precooling capacity, energy savings and water consumption of an indirect evaporative precooler. These indices can be used for cooling systems with continuous operation, but further work is needed to determine whether the same indices are also suitable for cooling systems with intermittent operations.

Chen, P.; Qin, H.; Huang, Y.J.; Wu, H.; Blumstein, C.

1992-09-01T23:59:59.000Z

309

Managing steam and concentration disturbances in multi-effect evaporators via  

E-Print Network [OSTI]

Managing steam and concentration disturbances in multi-effect evaporators via nonlinear modelling performance due to steam and concentration disturbances. An alternative architecture is then proposed which mill, the volatile component is water, with the remainder being sugar. Steam is used as a heating

Gravdahl, Jan Tommy

310

Microscopic simulations of molecular cluster decay: Does the carrier gas affect evaporation?  

E-Print Network [OSTI]

the sys- tems in question. An example of a practical problem is the behavior of steam in turbines, whereMicroscopic simulations of molecular cluster decay: Does the carrier gas affect evaporation? Hoi Yu water droplets produced through condensation in the transition from dry to wet steam can lead

Ford, Ian

311

Estimating the Evaporative Cooling Bias of an Airborne Reverse Flow Thermometer YONGGANG WANG AND BART GEERTS  

E-Print Network [OSTI]

Estimating the Evaporative Cooling Bias of an Airborne Reverse Flow Thermometer YONGGANG WANG form 24 June 2008) ABSTRACT Airborne reverse flow immersion thermometers were designed to prevent in cloud is surmised because air decelerates into the thermometer housing, and thus is heated and becomes

Geerts, Bart

312

Three-wire magnetic trap for direct forced evaporative cooling Shengwang Du1,* and Eun Oh2  

E-Print Network [OSTI]

Three-wire magnetic trap for direct forced evaporative cooling Shengwang Du1,* and Eun Oh2 1 Kong, China 2 U.S. Naval Research Laboratory, Remote Sensing Division, Washington, D.C. 20375, USA potential for direct forced evaporative cooling of neutral atoms without using induced spin

Du, Shengwang

313

Lab-on-a-Chip Sensor with Evaporated Bismuth Film Electrode for Anodic Stripping Voltammetry of Zinc  

E-Print Network [OSTI]

Lab-on-a-Chip Sensor with Evaporated Bismuth Film Electrode for Anodic Stripping Voltammetry voltammetry, Zinc, Lab-on-a-chip sensor, Dopamine, Evaporated Bi film electrode DOI: 10.1002/elan.201300349 1 negative potential window. Most importantly, it is much less toxic than mercury and is environmentally

Papautsky, Ian

314

Pulsed laser evaporation of boron/carbon pellets: Infrared spectra and quantum chemical structures and frequencies for BCp  

E-Print Network [OSTI]

Pulsed laser evaporation of boron/carbon pellets: Infrared spectra and quantum chemical structures March 1993) Pulsed laser evaporation of pellets pressed from boron and graphite powder gave a new 1 decreased with increasing B/C ratio in the pellet and with increasing laser power. Augmented coupled cluster

Martin, Jan M.L.

315

The contribution of evapotranspiration and evaporation to the water budget of a treatment wetland in Phoenix, AZ, USA  

E-Print Network [OSTI]

The contribution of evapotranspiration and evaporation to the water budget of a treatment wetland evapotranspiration and evaporation rates in a constructed treatment wetland in Phoenix during the summer, when both budget for the Tres Rios treatment wetland, and will improve our general knowledge of wetland water

Hall, Sharon J.

316

Intrinsic AGN Absorption Lines  

E-Print Network [OSTI]

Strong absorption lines are common in rest-frame UV spectra of AGNs due to a variety of resonant transitions, for example the HI Lyman series lines (most notably Ly-alpha 1216) and high-ionization doublets like CIV 1549,1551. The lines are called ``intrinsic'' if the absorbing gas is physically related to the AGN, e.g. if the absorber resides broadly within the radius of the AGN's surrounding ``host'' galaxy. Intrinsic absorption lines are thus valuable probes of the kinematics, physical conditions and elemental abundances in the gas near AGNs. Studies of intrinsic absorbers have historically emphasized the broad absorption lines (BALs) in quasars. Today we recognize a wider variety of intrinsic lines in a wider range of objects. For example, we now know that Seyfert 1 galaxies (the less luminous cousins of quasars) have intrinsic absorption. We also realize that intrinsic lines can form in a range of AGN environments --- from the dynamic inner regions like the BALs, to the more quiescent outer host galaxies >10 kpc away. This article provides a brief introduction to current observational and theoretical work on intrinsic AGN absorbers.

Fred Hamann

2000-06-12T23:59:59.000Z

317

Coherent soliton communication lines  

SciTech Connect (OSTI)

The data transmission in coherent fiber-optical communication lines using solitons with a variable phase is studied. It is shown that nonlinear coherent structures (solitons) can be applied for effective signal transmission over a long distance using amplitude and optical-phase keying of information. The optimum ratio of the pulse width to the bit slot at which the spectral efficiency (transmitted bits per second and hertz) is maximal is determined. It is shown that soliton fiber-optical communication lines can ensure data transmission at a higher spectral efficiency as compared to traditional communication lines and at a high signal-to-noise ratio.

Yushko, O. V., E-mail: olesya.yushko@gmail.com; Redyuk, A. A.; Fedoruk, M. P.; Turitsyn, S. K. [Novosibirsk State University (Russian Federation)

2014-11-15T23:59:59.000Z

318

A Simple Analytical Model of Evaporation in the Presence of Roots  

E-Print Network [OSTI]

Root systems can influence the dynamics of evapotranspiration of water out of a porous medium. The coupling of evapotranspiration remains a key aspect affecting overall root behavior. Predicting the evapotranspiration curve in the presence of roots helps keep track of the amount of water that remains in the porous medium. Using a controlled visual set-up of a 2D model soil system consisting of monodisperse glass beads, we first perform experiments on actual roots grown in partially saturated systems under different relative humidity conditions. We record parameters such as the total mass loss in the medium and the resulting position of the receding fronts and use these experimental results to develop a simple analytical model that predicts the position of the evaporating front as a function of time as well as the total amount of water that is lost from the medium due to the combined effects of evaporation and transpiration. The model is based on fundamental principles of evaporation flux and includes empirical assumptions on the quantity of stoma in the leaves and the transition time between regime 1 and regime 2. The model also underscores the importance of a much prolonged root life as long as the root is exposed to a partially saturated zone composed of a mixture of air and water. Comparison between the model and experimental results shows good prediction of the position of the evaporating front as well as the total mass loss from evapotranspiration in the presence of real root systems. These results provide additional understanding of both complex evaporation phenomenon and its influence on root mechanisms.

Cesare M. Cejas; Larry Hough; Jean-Christophe Castaing; Christian Fretigny; Remi Dreyfus

2014-06-17T23:59:59.000Z

319

Electric Transmission Lines (Iowa)  

Broader source: Energy.gov [DOE]

Electric transmission lines capable of operating at 69 kV or greater cannot be constructed along, across, or over any public highways or grounds outside of cities without a franchise from the...

320

Holes in Spectral Lines  

E-Print Network [OSTI]

The decay of an atom in the presence of a static perturbation is investigated. The perturbation couples a decaying state with a nondecaying state. A "hole" appears in the emission line at a frequency equal to the frequency ...

Fontana, Peter R.; Srivastava, Rajendra P.

1973-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "lined evaporation pond" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Power line detection system  

DOE Patents [OSTI]

A short-range, radio frequency (RF) transmitting-receiving system that provides both visual and audio warnings to the pilot of a helicopter or light aircraft of an up-coming power transmission line complex. Small, milliwatt-level narrowband transmitters, powered by the transmission line itself, are installed on top of selected transmission line support towers or within existing warning balls, and provide a continuous RF signal to approaching aircraft. The on-board receiver can be either a separate unit or a portion of the existing avionics, and can also share an existing antenna with another airborne system. Upon receipt of a warning signal, the receiver will trigger a visual and an audio alarm to alert the pilot to the potential power line hazard.

Latorre, Victor R. (Tracy, CA); Watwood, Donald B. (Tracy, CA)

1994-01-01T23:59:59.000Z

322

Power line detection system  

DOE Patents [OSTI]

A short-range, radio frequency (RF) transmitting-receiving system that provides both visual and audio warnings to the pilot of a helicopter or light aircraft of an up-coming power transmission line complex. Small, milliwatt-level narrowband transmitters, powered by the transmission line itself, are installed on top of selected transmission line support towers or within existing warning balls, and provide a continuous RF signal to approaching aircraft. The on-board receiver can be either a separate unit or a portion of the existing avionics, and can also share an existing antenna with another airborne system. Upon receipt of a warning signal, the receiver will trigger a visual and an audio alarm to alert the pilot to the potential power line hazard. 4 figs.

Latorre, V.R.; Watwood, D.B.

1994-09-27T23:59:59.000Z

323

Line Extension Alternatives  

Broader source: Energy.gov [DOE]

The Public Service Board (PSB) of Vermont developed rules regarding utility line extension requests. While the majority of the rules focus on the procedure followed (and associated fees) for the...

324

Cold tolerance of red drum (Sciaenops ocellatus) and thermal-refuge technology to protect this species from cold-kill in aquaculture ponds  

E-Print Network [OSTI]

.004 to 0.006 min-' for the 1992-93 version (r > 0.99). A second phase of the research focused on cold tolerance of red drum in ponds at Palacios, from 6 February to 2 April 1993. Values of the 24-h lower lethal temperature of fish sampled from refuge...

Dorsett, Paul Wesley

2012-06-07T23:59:59.000Z

325

Survey of Radionuclide Distributions Resulting from the Church Rock, New Mexico, Uranium Mill Tailings Pond Dam Failure  

SciTech Connect (OSTI)

An intensive site survey and on-site analysis program were conducted to evaluate the distribution of four radionucliGes in the general vicinity of Gallup, New Mexico, subsequent to the accidental breach of a uranium mill tailings pond dam and the release of a large quantity of tailings pond materials. The objective of this work was to determine the distribution and concentration levels of {sup 210}Pb, {sup 226}Ra, {sup 230}Th, and {sup 238}U in the arroyo that is immediately adjacent to the uranium tailings pond (pipeline arroyo) and in the Rio Puerco arroyo into which the pipeline arroyo drains. An intensive survey between the United Nuclear Corporation (UNC) Church Rock Mill site and the New Mexico-Arizona state border was performed. Sampling locations were established at approximately 500-ft intervals along the arroyo. During the weeks of September 24 through October 5, 1979, a series of samples was collected from alternate sampling locations along the arroyo. The purpose of this collection of samples and their subsequent analysis was to provide an immediate evaluation of the extent and the levels of radioactive contamination. The data obtained from this extensive survey were then compared to action levels which had been proposed by the Nuclear Regulatory Commission and were adapted by the New Mexico Environmental Improvement Division (NMEID) for {sup 230}Th and {sup 226}Ra concentrations that would require site cleanup. The Pacific Northwest Laboratory/Nuclear Regulatory Commission mobile laboratory van was on-site at the UNC Church Rock Mill from September 22, 1979, through December 13, 1979, and was manned by one or more PNL personnel for all but four weeks of this time period. Approximately 1200 samples associated with the Rio Puerco survey were analyzed 1n the laboratory. An additional 1200 samples related to the Rio Puerco cleanup operations which the United Nuclear Corporation was conducting were analyzed on-site in the mobile laboratory. The purpose of these analyses was to determine the effectiveness of the cleanup operations that were ongoing and to evaluate what additional cleanup would be required. This on-site analysis of radioactive contamination constituted the principal task of this project, with the identification of those portions of the arroyo exceeding the NMEID proposed cleanup criteria being the major output. Additiond1 tasks included an evaluation of the initial soil sampling scheme (letter from T. Wolff [NMEID] to J. Abiss [UNC]. oated September 25, 1979) and the proposed NMEID verification sampling scheme (letter from T. Buhl [NMEID] to H. Miller [NRC]. dated April 23, 1980).

Weimer, W. C.; Kinnison, R. R.; Reeves, J. H.

1981-12-01T23:59:59.000Z

326

Transmission line capital costs  

SciTech Connect (OSTI)

The displacement or deferral of conventional AC transmission line installation is a key benefit associated with several technologies being developed with the support of the U.S. Department of Energy`s Office of Energy Management (OEM). Previous benefits assessments conducted within OEM have been based on significantly different assumptions for the average cost per mile of AC transmission line. In response to this uncertainty, an investigation of transmission line capital cost data was initiated. The objective of this study was to develop a database for preparing preliminary estimates of transmission line costs. An extensive search of potential data sources identified databases maintained by the Bonneville Power Administration (BPA) and the Western Area Power Administration (WAPA) as superior sources of transmission line cost data. The BPA and WAPA data were adjusted to a common basis and combined together. The composite database covers voltage levels from 13.8 to 765 W, with cost estimates for a given voltage level varying depending on conductor size, tower material type, tower frame type, and number of circuits. Reported transmission line costs vary significantly, even for a given voltage level. This can usually be explained by variation in the design factors noted above and variation in environmental and land (right-of-way) costs, which are extremely site-specific. Cost estimates prepared from the composite database were compared to cost data collected by the Federal Energy Regulatory Commission (FERC) for investor-owned utilities from across the United States. The comparison was hampered because the only design specifications included with the FERC data were voltage level and line length. Working within this limitation, the FERC data were not found to differ significantly from the composite database. Therefore, the composite database was judged to be a reasonable proxy for estimating national average costs.

Hughes, K.R.; Brown, D.R.

1995-05-01T23:59:59.000Z

327

Q. J. R. Meteorol. Soc. (2006), 132, pp. 865883 doi: 10.1256/qj.04.187 Observations of the depth of ice particle evaporation  

E-Print Network [OSTI]

) suggested that evaporative cooling from falling ice particles can have a more significant dynamical impact of ice particle evaporation beneath frontal cloud to improve NWP modelling By RICHARD M. FORBES1 21 November 2005) SUMMARY The evaporation (sublimation) of ice particles beneath frontal ice cloud

Reading, University of

328

Flue gas desulfurization sludge: establishment of vegetation on ponded and soil-applied waste. Final report January 1977-September 1981  

SciTech Connect (OSTI)

The report gives results of research to identify and evaluate forms of vegetation and methods of their establishment for reclaiming retired flue gas desulfurization sludge ponds. Also studied were the soil liming value of limestone scrubber sludge (LSS) and plant uptake and percolation losses of some chemical nutrients in the sludge. Several vegetation schemes were evaluated between 1977 and 1982 for covering and stabilizing LSS at Colbert Steam Plant, Cherokee, AL, and Shawnee Steam Plant, Paducah, KY. Eleven tree and 10 grass or legume species were tested for adaptability and survival when planted directly in LSS or in LSS amended with soil, municipal sewage sludge, or standard potting mix. Other studies indicated that LSS apparently has sufficient unreacted limestone to be a satisfactory soil liming agent.

Giordano, P.M.; Mays, D.A.; Soileau, J.M.

1984-01-01T23:59:59.000Z

329

Supercritical fluid extraction of bitumen free solids separated from Athabasca oil sand feed and hot water process tailings pond sludge  

SciTech Connect (OSTI)

The presence of strongly bound organic matter (SOM), in association with certain solids fractions, causes serious problems in the processability of Athabasca oil sands as well as in the settling and compaction of hot water process tailing pond sludge. It has been demonstrated that a substantial amount of this SOM can be separated from oil sands feed and sludge solids, after removal of bitumen by toluene, using a supercritical fluid extraction (SFE) method. The extracted material is soluble in common organic solvents which allows a direct comparison, between the SOM separated from oil sands and sludges, from the point of view of both gross analysis of the major compound types and detailed analysis of chemical structures.

Kotlyar, L.S.; Sparks, B.D.; Woods, J.R.; Ripmeester, J.A. (National Research Council of Canada, Ottawa, ON (Canada). Div. of Chemistry)

1990-01-01T23:59:59.000Z

330

Temperature and humidity control during cooling and dehumidifying by compressor and evaporator fan speed variation  

SciTech Connect (OSTI)

The accurate control of temperature and relative humidity during cooling and dehumidifying air-conditioning processes may be achieved by compressor and evaporator fan speed variation. Proportional-integral-differential (PID) control methods are shown to be suitable for attaining compressor and evaporator fan speeds such that the sensible and latent components of the refrigeration system capacity equal the sensible and latent components of the system load. The feasibility of the control method has been verified experimentally. A numerical model of an environmental control system, including refrigeration, space, and PID control subsystems, has been developed. The model is suitable for determining system response to variations of PID coefficient values and to variations of system loads.

Krakow, K.I.; Lin, S.; Zeng, Z.S. [Concordia Univ., Montreal, Quebec (Canada). Dept. of Mechanical Engineering

1995-08-01T23:59:59.000Z

331

Control of pyrophoricity in deposits produced by electron beam evaporation of uranium  

SciTech Connect (OSTI)

A description is given of an apparatus for reducing the pyrophoricity of deposits of a material evaporated within a chamber comprising: a sealed chamber defined by an enclosure; means for providing within said chamber an atmosphere of generally non-reactive nature; a reservoir of a material to ve evaporated; means for directing a vapor of said material from said reservoir into said chamber; at least one surface within said chamber in the path of the directed vapor and on which at least portions of the vaporized material deposits; means for cooling said enclosure to a temperature at which said vapor deposits at a relatively low pyrophoric density; and means for maintaining a temperature for said collection surfaces higher than the enclosure temperature to promote deposition of said material at a relatively higher density.

Clifford, J.

1980-07-01T23:59:59.000Z

332

Analysis of multicomponent evaporation in electron beam melting and refining of titanium alloys  

SciTech Connect (OSTI)

Experimental evidence and a mathematical model are presented to evaluate the effect of beam-scan frequency on composition change in electron-beam melting of titanium alloys. Experiments characterized the evaporation rate of commercially pure (CP) titanium and vapor composition over titanium alloy with up to 6 wt pct aluminum and 4.5 wt pct vanadium, as a function of beam power, scan frequency, and background pressure. These data and thermal mapping of the hearth melt surface are used to estimate activity coefficients of aluminum and vanadium in the hearth. The model describes transient heat transfer in the surface of the melt and provides a means of estimating enhancement of pure titanium evaporation and change in final aluminum composition due to local heating at moderate beam-scan frequencies.

Powell, A.; Szekely, J.; Pal, U. [Massachusetts Inst. of Tech., Cambridge, MA (United States). Dept. of Materials Science and Engineering; Avyle, J. van den; Damkroger, B. [Sandia National Labs., Albuquerque, NM (United States). Materials Processing Dept.

1997-12-01T23:59:59.000Z

333

Co-Evaporated Cu2ZnSnSe4 Films and Devices  

SciTech Connect (OSTI)

The use of vacuum co-evaporation to produce Cu2ZnSnSe4 photovoltaic devices with 9.15% total-area efficiency is described. These new results suggest that the early success of the atmospheric techniques for kesterite photovoltaics may be related to the ease with which one can control film composition and volatile phases, rather than a fundamental benefit of atmospheric conditions for film properties. The co-evaporation growth recipe is documented, as is the motivation for various features of the recipe. Characteristics of the resulting kesterite films and devices are shown in scanning electron micrographs, including photoluminescence, current-voltage, and quantum efficiency. Current-voltage curves demonstrate low series resistance without the light-dark cross-over seen in many devices in the literature. Band gap indicated by quantum efficiency and photoluminescence is roughly consistent with that expected from first principles calculation.

Repins, I.; Beall, C.; Vora, N.; DeHart, C.; Kuciauskas, D.; Dippo, P.; To, B.; Mann, J.; Hsu, W. C.; Goodrich, A.; Noufi, R.

2012-06-01T23:59:59.000Z

334

Comparisons of Statistical Multifragmentation and Evaporation Models for Heavy Ion Collisions  

E-Print Network [OSTI]

The results from ten statistical multifragmentation models have been compared with each other using selected experimental observables. Even though details in any single observable may differ, the general trends among models are similar. Thus these models and similar ones are very good in providing important physics insights especially for general properties of the primary fragments and the multifragmentation process. Mean values and ratios of observables are also less sensitive to individual differences in the models. In addition to multifragmentation models, we have compared results from five commonly used evaporation codes. The fluctuations in isotope yield ratios are found to be a good indicator to evaluate the sequential decay implementation in the code. The systems and the observables studied here can be used as benchmarks for the development of statistical multifragmentation models and evaporation codes.

Tsang, M B; Charity, R; Durand, D; Friedman, W A; Gulminelli, F; Lefvre, A; Raduta, A H; Raduta, A R; Souza, S; Trautmann, W; Wada, R; Raduta, Ad.R.; Raduta, Al. H.

2006-01-01T23:59:59.000Z

335

Evaporation behavior of Hastelloy-X alloys in simulated very high temperature reactor environments  

SciTech Connect (OSTI)

A sequential analysis was made on the material degradations during exposure of nickel-base corrosionresistant austenitic alloys to simulated very high temperature reactor environments. The materials tested were two modified versions of Hastelloy-X in terms of both increased manganese content for improved compatibility and decreased manganese content for possible adverse effects. Quantitative analysis of the specimens after exposure for 1000 h at several temperature steps from 850 to 1050/sup 0/C have revealed the temperature-dependent aspects of the processes including the depletion of chromium and manganese due to oxidation, evaporation, and carbon transfer into and/or from the materials. The material with enriched manganese, developed and specified as Hastelloy-XR, showed enhanced resistance to loss of chromium in terms of both oxidation and evaporation.

Shindo, M.; Kondo, T.

1984-08-01T23:59:59.000Z

336

Enhanced Fusion-Evaporation Cross Sections in Neutron-Rich $^{132}$Sn on $^{64}$Ni  

E-Print Network [OSTI]

Evaporation residue cross sections have been measured with neutron-rich radioactive $^{132}$Sn beams on $^{64}$Ni in the vicinity of the Coulomb barrier. The average beam intensity was $2\\times 10^{4}$ particles per second and the smallest cross section measured was less than 5 mb. Large subbarrier fusion enhancement was observed. Coupled-channels calculations taking into account inelastic excitation and neutron transfer underpredict the measured cross sections below the barrier.

J. F. Liang; D. Shapira; C. J. Gross; J. R. Beene; J. D. Bierman; A. Galindo-Uribarri; J. Gomez del Campo; P. A. Hausladen; Y. Larochelle; W. Loveland; P. E. Mueller; D. Peterson; D. C. Radford; D. W. Stracener; R. L. Varner

2003-04-02T23:59:59.000Z

337

Characterization Results For The 2013 HTF 3H Evaporator Overhead Samples  

SciTech Connect (OSTI)

This report tabulates the radiochemical analysis of the 3H evaporator overhead sample for {sup 137}Cs, {sup 90}Sr, and {sup 129}I to meet the requirements in the Effluent Treatment Project (ETP) Waste Acceptance Criteria (WAC) (rev. 6). This report identifies the sample receipt date, preparation method, and analysis performed in the accumulation of the listed values. All data was found to be within the ETP WAC (rev. 6) specification for the Waste Water Collection Tanks (WWCT).

Washington, A. L. II

2013-12-04T23:59:59.000Z

338

Economic and Technical Tradeoffs Between Open and Closed Cycle Vapor Compression Evaporators  

E-Print Network [OSTI]

compressor. The blowers and centrifugal compressors used for steam recompression are limited to compression ratios of around 2:1 in a single stage. This compression ratio is perfectly adequate for many applications. But if a larger driving force with a... higher compression ratio is desired. two or more compression stages must be used resulting in sig nificantly increased compressor costs. Closed Cycle Vapor Compression A schematic of a closed cycle vapor compression evaporator is shown in Figure 3...

Timm, M. L.

339

Heat transfer through horizontal films of liquids evaporating under high vacuum  

E-Print Network [OSTI]

generally have been accomplished by the use of vacuum systems' However, in the past the systems were rarely operated under 100 mm of mercury pressure. Some evaporation processes were operated under this limit but the majority of the vacuum operations... plate fractionater described by Cronan (7) operates at a pressure of 1 mm of mercury. The need of processing industries to go to higher vacuum systems has caused a reappraisal of engineering data in this field. Very little data have been published...

Stiles, Graham Bill

1961-01-01T23:59:59.000Z

340

Fluorocarbon evaporative cooling developments for the ATLAS pixel and semiconductor tracking detectors  

E-Print Network [OSTI]

Heat transfer coefficients 2-5.103 Wm-2K-1 have been measured in a 3.6 mm I.D. heated tube dissipating 100 Watts - close to the full equivalent power (~110 W) of a barrel SCT detector "stave" - over a range of power dissipations and mass flows in the above fluids. Aspects of full-scale evaporative cooling circulator design for the ATLAS experiment are discussed, together with plans for future development.

Anderssen, E; Berry, S; Bonneau, P; Bosteels, Michel; Bouvier, P; Cragg, D; English, R; Godlewski, J; Grski, B; Grohmann, S; Hallewell, G D; Hayler, T; Ilie, S; Jones, T; Kadlec, J; Lindsay, S; Miller, W; Niinikoski, T O; Olcese, M; Olszowska, J; Payne, B; Pilling, A; Perrin, E; Sandaker, H; Seytre, J F; Thadome, J; Vacek, V

1999-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "lined evaporation pond" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Construction of a Penrose Diagram for a Spatially Coherent Evaporating Black Hole  

E-Print Network [OSTI]

A Penrose diagram is constructed for an example black hole that evaporates at a steady rate as measured by a distant observer, until the mass vanishes, yielding a final state Minkowski space-time. Coordinate dependencies of significant features, such as the horizon and coordinate anomalies, are clearly demonstrated on the diagram. The large-scale causal structure of the space-time is briefly discussed.

Beth A. Brown; James Lindesay

2007-10-10T23:59:59.000Z

342

Investigation of an electron beam evaporative source: Part 1, Theory; Part 2, Measurements  

SciTech Connect (OSTI)

A theory for evaluating the performance parameters of linear electron beam evaporative source is presented. The electron beam is considered to be generated from a linear gun and its trajectory is curved by a uniform magnetic field onto a target. A model has been developed to estimate the trajectory of the electron beam. The performance of the electron gun is characterized by two coefficients: {alpha}, the divergence effect of the beam as it enters into the electric field free space region, and {Beta}, the space charge parameter, which is proportional to the magnitude of the current density of the beam. These two parameters determine the location (angular position) of the beam waist and the current density at the target. In addition, neutralization of the electron space charge by vapor ions generated near the target is considered. A discussion is also given of the shape of the depression in the surface of the molten metal, which is due to the pressure on the surface associated with the momentum recoil from the evaporative vapor flux. By relating the characteristic depth and width of the depression to magnitude and the shape of the pressure profile, useful analytical and numerical results are presented for a given pressure profile. The implication of the results for the design of electron beam evaporative sources are also discussed. Measurements are discussed a the end of the paper. 11 refs., 15 figs.

Sze, J.S.; Self, S.A. (Lawrence Livermore National Lab., CA (USA))

1989-09-14T23:59:59.000Z

343

Thermal properties of light nuclei from $^{12}$C+$^{12}$C fusion-evaporation reactions  

E-Print Network [OSTI]

The $^{12}$C+$^{12}$C reaction at 95 MeV has been studied through the complete charge identification of its products by means of the GARFIELD+RCo experimental set-up at INFN Laboratori Nazionali di Legnaro (LNL). In this paper, the first of a series of two, a comparison to a dedicated Hauser-Feshbach calculation allows to select a set of dissipative events which corresponds, to a large extent, to the statistical evaporation of highly excited $^{24}$Mg. Information on the isotopic distribution of the evaporation residues in coincidence with their complete evaporation chain is also extracted. The set of data puts strong constraints on the behaviour of the level density of light nuclei above the threshold for particle emission. In particular, a fast increase of the level density parameter with excitation energy is supported by the data. Residual deviations from a statistical behaviour are seen in two specific channels, and tentatively associated with a contamination from direct reactions and/or $\\alpha$-clustering effects. These channels are studied in further details in the second paper of the series.

L Morelli; G Baiocco; M D'Agostino; F Gulminelli; M Bruno; U Abbondanno; S Appannababu; S Barlini; M Bini; G Casini; M Cinausero; M Degerlier; D Fabris; N Gelli; F Gramegna; V L Kravchuk; T Marchi; G Pasquali; S Piantelli; S Valdr; Ad R Raduta

2014-04-14T23:59:59.000Z

344

Omega Transmission Lines  

E-Print Network [OSTI]

In this paper, we show how bi-anisotropic media with omega-type response can be realized using periodically loaded transmission lines. General conditions for the needed unit cell circuit block are derived. Also, an implementation is shown and analyzed.

Vehmas, Joni

2013-01-01T23:59:59.000Z

345

The design and evaluation of a water delivery system for evaporative cooling of a proton exchange membrane fuel cell  

E-Print Network [OSTI]

An investigation was performed to demonstrate system design for the delivery of water required for evaporative cooling of a proton exchange membrane fuel cell (PEMFC). The water delivery system uses spray nozzles capable of injecting water directly...

Al-Asad, Dawood Khaled Abdullah

2009-06-02T23:59:59.000Z

346

Printed circuit dispersive transmission line  

DOE Patents [OSTI]

A printed circuit dispersive transmission line structure is disclosed comprising an insulator, a ground plane formed on one surface of the insulator, a first transmission line formed on a second surface of the insulator, and a second transmission line also formed on the second surface of the insulator and of longer length than the first transmission line and periodically intersecting the first transmission line. In a preferred embodiment, the transmission line structure exhibits highly dispersive characteristics by designing the length of one of the transmission line between two adjacent periodic intersections to be longer than the other. 5 figures.

Ikezi, H.; Lin-Liu, Y.R.; DeGrassie, J.S.

1991-08-27T23:59:59.000Z

347

Project C-018H, 242-A Evaporator/PUREX Plant Process Condensate Treatment Facility, functional design criteria. Revision 3  

SciTech Connect (OSTI)

This document provides the Functional Design Criteria (FDC) for Project C-018H, the 242-A Evaporator and Plutonium-Uranium Extraction (PUREX) Plant Condensate Treatment Facility (Also referred to as the 200 Area Effluent Treatment Facility [ETF]). The project will provide the facilities to treat and dispose of the 242-A Evaporator process condensate (PC), the Plutonium-Uranium Extraction (PUREX) Plant process condensate (PDD), and the PUREX Plant ammonia scrubber distillate (ASD).

Sullivan, N.

1995-05-02T23:59:59.000Z

348

APPLICATION OF A THIN FILM EVAPORATOR SYSTEM FOR MANAGEMENT OF LIQUID HIGH-LEVEL WASTES AT HANFORD  

SciTech Connect (OSTI)

A modular, transportable evaporator system, using thin film evaporative technology, is planned for deployment at the Hanford radioactive waste storage tank complex. This technology, herein referred to as a wiped film evaporator (WFE), will be located at grade level above an underground storage tank to receive pumped liquids, concentrate the liquid stream from 1.1 specific gravity to approximately 1.4 and then return the concentrated solution back into the tank. Water is removed by evaporation at an internal heated drum surface exposed to high vacuum. The condensed water stream will be shipped to the site effluent treatment facility for final disposal. This operation provides significant risk mitigation to failure of the aging 242-A Evaporator facility; the only operating evaporative system at Hanford maximizing waste storage. This technology is being implemented through a development and deployment project by the tank farm operating contractor, Washington River Protection Solutions (WRPS), for the Office of River Protection/Department of Energy (ORP/DOE), through Columbia Energy & Environmental Services, Inc. (Columbia Energy). The project will finalize technology maturity and install a system at one of the double-shell tank farms. This paper discusses results of pre-project pilot-scale testing by Columbia Energy and ongoing technology maturation development scope through fiscal year 2012, including planned additional pilot-scale and full-scale simulant testing and operation with actual radioactive tank waste.

TEDESCHI AR; WILSON RA

2010-01-14T23:59:59.000Z

349

Drill string transmission line  

DOE Patents [OSTI]

A transmission line assembly for transmitting information along a downhole tool comprising a pin end, a box end, and a central bore traveling between the pin end and the box end, is disclosed in one embodiment of the invention as including a protective conduit. A transmission line is routed through the protective conduit. The protective conduit is routed through the central bore and the ends of the protective conduit are routed through channels formed in the pin end and box end of the downhole tool. The protective conduit is elastically forced into a spiral or other non-linear path along the interior surface of the central bore by compressing the protective conduit to a length within the downhole tool shorter than the protective conduit.

Hall, David R. (Provo, UT); Hall, Jr., H. Tracy (Provo, UT); Pixton, David S. (Lehi, UT); Bradford, Kline (Orem, UT); Fox, Joe (Spanish Fork, UT)

2006-03-28T23:59:59.000Z

350

Corrective Action Decision Document/Closure Report for Corrective Action Unit 478: Area 12 T-Tunnel Ponds, Nevada Test Site  

SciTech Connect (OSTI)

This Corrective Action Decision Document (CADD)/Closure Report (CR) was prepared by the Defense Threat Reduction Agency (DTRA) for Corrective Action Unit (CAU) 478, Area 12 T-Tunnel Ponds. This CADD/CR is consistent with the requirements of the Federal Facility Agreement and Consent Order (FFACO) agreed to by the State of Nevada, the U.S. Department of Energy (DOE), and the U.S. Department of Defense. Corrective Action Unit 478 is comprised of one corrective action site (CAS): 12-23-01, Ponds (5) RAD Area The purpose of this CADD/CR is to provide justification and documentation supporting the recommendation for closure in place with use restrictions for CAU 478.

NSTec Environmental Restoration

2010-03-15T23:59:59.000Z

351

2011 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site's Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond  

SciTech Connect (OSTI)

This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (LA-000160-01), for the wastewater reuse site at the Idaho National Laboratory Site's Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond from November 1, 2010 through October 31, 2011. The report contains the following information: (1) Facility and system description; (2) Permit required effluent monitoring data and loading rates; (3) Groundwater monitoring data; (4) Status of special compliance conditions; and (5) Discussion of the facility's environmental impacts. During the 2011 reporting year, an estimated 6.99 million gallons of wastewater were discharged to the Industrial Waste Ditch and Pond which is well below the permit limit of 13 million gallons per year. Using the dissolved iron data, the concentrations of all permit-required analytes in the samples from the down gradient monitoring wells were below the Ground Water Quality Rule Primary and Secondary Constituent Standards.

David Frederick

2012-02-01T23:59:59.000Z

352

2013 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Sites Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond  

SciTech Connect (OSTI)

This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (WRU-I-0160-01, formerly LA 000160 01), for the wastewater reuse site at the Idaho National Laboratory Sites Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond from November 1, 2012 through October 31, 2013. The report contains the following information: Facility and system description Permit required effluent monitoring data and loading rates Groundwater monitoring data Status of special compliance conditions Discussion of the facilitys environmental impacts During the 2013 reporting year, an estimated 9.64 million gallons of wastewater were discharged to the Industrial Waste Ditch and Pond which is well below the permit limit of 17 million gallons per year. The concentrations of all permit-required analytes in the samples from the down gradient monitoring wells were below the applicable Idaho Department of Environmental Qualitys groundwater quality standard levels.

Mike Lewis

2014-02-01T23:59:59.000Z

353

2012 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Sites Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond  

SciTech Connect (OSTI)

This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (WRU-I-0160-01, formerly LA 000160 01), for the wastewater reuse site at the Idaho National Laboratory Sites Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond from November 1, 2011 through October 31, 2012. The report contains the following information: Facility and system description Permit required effluent monitoring data and loading rates Groundwater monitoring data Status of special compliance conditions Discussion of the facilitys environmental impacts During the 2012 reporting year, an estimated 11.84 million gallons of wastewater were discharged to the Industrial Waste Ditch and Pond which is well below the permit limit of 17 million gallons per year. The concentrations of all permit-required analytes in the samples from the down gradient monitoring wells were below the Ground Water Quality Rule Primary and Secondary Constituent Standards.

Mike Lewis

2013-02-01T23:59:59.000Z

354

2010 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site's Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond  

SciTech Connect (OSTI)

This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (#LA 000160 01), for the wastewater reuse site at the Idaho National Laboratory Sites Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond from May 1, 2010 through October 31, 2010. The report contains the following information: Facility and system description Permit required effluent monitoring data and loading rates Groundwater monitoring data Status of special compliance conditions Discussion of the facilitys environmental impacts During the 2010 partial reporting year, an estimated 3.646 million gallons of wastewater were discharged to the Industrial Waste Ditch and Pond which is well below the permit limit of 13 million gallons per year. The concentrations of all permit-required analytes in the samples from the down gradient monitoring wells were below the Ground Water Quality Rule Primary and Secondary Constituent Standards.

David B. Frederick

2011-02-01T23:59:59.000Z

355

Chemical treatment of simulated solution of evaporator concentrate for immobilization in bitumen  

SciTech Connect (OSTI)

Radioactive liquid and solid wastes are generated from different sections of reactor and radiochemical laboratories associated with nuclear power plants. Liquid radioactive wastes originate from the boric acid control system for safe operation of nuclear power reactors. Studies on the preparation of leach-resistant insoluble boron compound from simulated solution of evaporator concentrate are reported in this work. The insoluble compound CaB{sub 6}O{sub 10}{center_dot}4H{sub 2}O has been prepared from simulated solution of evaporator concentrate by chemical treatment with calcium chloride solution. Other insoluble compounds CaB{sub 2}O{sub 4}{center_dot}6H{sub 2}O/Ca{sub 3}B{sub 4}O{sub 9}{center_dot}9H{sub 2}O/Ca[B(OH){sub 4}]{sub 2}{center_dot}2H{sub 2}O and NaCaB{sub 5}O{sub 6}{center_dot}8H{sub 2}O/NaCaB{sub 5}O{sub 6}{center_dot}5H{sub 2}O/Ca{sub 2}B{sub 6}O{sub 11}{center_dot}13H{sub 2}O have been prepared from simulated solution of evaporator concentrate with calcium hydroxide under controlled conditions of temperature and time. Identification and characterization of these compounds have been done by X-ray diffraction, optical microscopy and differential thermal and thermogravimetric analysis. For low-level radioactive waste treatment, immobilization of insoluble borate compounds in bitumen will produce leach-resistant suitable waste product for safe disposal.

Awwal, M.A.; Guzella, M.F.R.; Silva, T.V. [National Nuclear Energy Commission, Belo Horizonte, Minas Gerais (Brazil). Nuclear Technology Development Centre] [National Nuclear Energy Commission, Belo Horizonte, Minas Gerais (Brazil). Nuclear Technology Development Centre

1996-12-31T23:59:59.000Z

356

Seminar 14 - Desiccant Enhanced Air Conditioning: Desiccant Enhanced Evaporative Air Conditioning (Presentation)  

SciTech Connect (OSTI)

This presentation explains how liquid desiccant based coupled with an indirect evaporative cooler can efficiently produce cool, dry air, and how a liquid desiccant membrane air conditioner can efficiently provide cooling and dehumidification without the carryover problems of previous generations of liquid desiccant systems. It provides an overview to a liquid desiccant DX air conditioner that can efficiently provide cooling and dehumidification to high latent loads without the need for reheat, explains how liquid desiccant cooling and dehumidification systems can outperform vapor compression based air conditioning systems in hot and humid climates, explains how liquid desiccant cooling and dehumidification systems work, and describes a refrigerant free liquid desiccant based cooling system.

Kozubal, E.

2013-02-01T23:59:59.000Z

357

Non Evaporable Getter (NEG) Pumps: a Route to UHV-XHV  

SciTech Connect (OSTI)

Non Evaporable Getter (NEG) technology has been developed in the 1970's and since then adopted by industry, R and D labs, research centres and in large physics projects like accelerators, synchrotrons and fusion reactors. NEG pumps are very compact and vibration-free devices able to deliver very high pumping with minimal power requirement and electromagnetic interference. In the present paper, main features and performances of getter pumps are reviewed and discussed with a special focus to photocathode gun application, where UHV or XHV conditions are mandatory to ensure adequate gun life. NEG coating and future challenges for NEG technology are also discussed.

Manini, Paolo [SAES Getters SpA, Viale Italia 77, 20010 Lainate (Italy)

2009-08-04T23:59:59.000Z

358

A simple, time-dependent formula for estimating evaporation rates in Texas  

E-Print Network [OSTI]

- dependent one is supuorted by careful consideration of the well-known evaporation formula offered by H. L. Penman 1n 1948. An examinati on of the bas1c assumptions of his phys1cally correct equat1on, espec1ally of those relevant to the energy env1ronment... 0. 9069 0. 8969 0. 9000 0. 9290 0. 9072 0. 8536 0. 9045 0. 8417 0. 9040 0. 9027 0. 8725 0. 8922 0. 9155 0. 8828 0. 9110 0. 8361 104. 7 75. 6 100. 9 78. 6 99. 3 106. 8 120. 2 94. 8 95. 7 97. 4 87. 0 90. 0 130. 8 97. 8 58...

Trenchard, Michael Howard

1976-01-01T23:59:59.000Z

359

Tank 30 and 37 Supernatant Sample Cross-Check and Evaporator Feed Qualification Analysis-2012  

SciTech Connect (OSTI)

This report summarizes the analytical data reported by the F/H and Savannah River National Laboratories for the 2012 cross-check analysis for high level waste supernatant liquid samples from SRS Tanks 30 and 37. The intent of this Tank 30 and 37 sample analyses was to perform cross-checks against routine F/H Laboratory analyses (corrosion and evaporator feed qualification programs) using samples collected at the same time from both tanks as well as split samples from the tanks.

Oji, L. N.

2013-03-07T23:59:59.000Z

360

A new limit on the rate-density of evaporating black holes  

SciTech Connect (OSTI)

Data taken with the CYGNUS detector between 1989 and 1993 have been used to search for 1 second bursts of ultra-high energy (UHE) gamma rays from any point in the northern sky. There is no evidence for such bursts. Therefore the theory-dependent upper limit on the rate-density of evaporating black holes is 6.1 [times] 10[sup 5]pc[sup [minus]3]yr[sup [minus]1] at the 99% C.L.. After renormalizing previous direct searches to the same theory, this limit is the most restrictive by more than 2 orders of magnitude.

Not Available

1993-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "lined evaporation pond" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

A new limit on the rate-density of evaporating black holes  

SciTech Connect (OSTI)

Data taken with the CYGNUS detector between 1989 and 1993 have been used to search for 1 second bursts of ultra-high energy (UHE) gamma rays from any point in the northern sky. There is no evidence for such bursts. Therefore the theory-dependent upper limit on the rate-density of evaporating black holes is 6.1 {times} 10{sup 5}pc{sup {minus}3}yr{sup {minus}1} at the 99% C.L.. After renormalizing previous direct searches to the same theory, this limit is the most restrictive by more than 2 orders of magnitude.

The CYGNUS Collaboration

1993-05-01T23:59:59.000Z

362

Imaging the condensation and evaporation of molecularly thin ethanol films with surface forces apparatus  

SciTech Connect (OSTI)

A new method for imaging condensation and evaporation of molecularly thin ethanol films is reported. It is found that the first adsorbed layer of ethanol film on mica surface behaves as solid like structure that cannot flow freely. With the increase of exposure time, more ethanol molecules condense over the mica surface in the saturated ethanol vapor condition. The first layer of adsorbed ethanol film is about 3.8 thick measured from the surface forces apparatus, which is believed to be the average diameter of ethanol molecules while they are confined in between two atomically smooth mica surfaces.

Zhao, Gutian; Tan, Qiyan; Xiang, Li; Zhang, Di; Ni, Zhonghua, E-mail: nzh2003@seu.edu.cn, E-mail: yunfeichen@seu.edu.cn; Yi, Hong; Chen, Yunfei, E-mail: nzh2003@seu.edu.cn, E-mail: yunfeichen@seu.edu.cn [Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, School of Mechanical Engineering, Southeast University, Nanjing 211189 (China)] [Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, School of Mechanical Engineering, Southeast University, Nanjing 211189 (China)

2014-01-15T23:59:59.000Z

363

A study of heat pump fin staged evaporators under frosting conditions  

E-Print Network [OSTI]

the performance of fin-and-tube outdoor coils as well as the whole heat pump system. The objective of the experimental part of this study was to investigate the effects of the staging fin on the frost/defrost performance of heat pump outdoor coils under different... and additional energy is used to melt the frost off the evaporator, the defrosting process increases energy consumption and reduces the seasonal efficiency of the heat pump. Frost formation and the subsequent defrost process continues to be a source...

Yang, Jianxin

2004-09-30T23:59:59.000Z

364

Two-phase, two-component Stirling engine with controlled evaporation  

SciTech Connect (OSTI)

In a Stirling-like engine, the specific power can be greatly increased by the use of a two-component, two-phase working fluid. Theory and experiments have indicated that a two- to threefold increase is easily attainable. This report shows that by controlling the rate at which the liquid is evaporated into the expansion cylinder, still larger increases may be achieved under quite reasonable operating conditions. Successful application of this principle would make it practicable to operate engines with moderate hot-end temperatures and perhaps even with the very low temperatures available from simple nontracking solar collectors.

West, C.D.

1982-12-01T23:59:59.000Z

365

Sensitivity of the FERMI Detectors to Gamma-Ray Bursts from Evaporating Primordial Black Holes (PBHs)  

E-Print Network [OSTI]

Primordial Black Holes (PBHs), which may have been created in the early Universe, are predicted to be detectable by their Hawking radiation. The Fermi Gamma-ray Space Telescope observatory offers increased sensitivity to the gamma-ray bursts produced by PBHs with an initial mass of $\\sim 5\\times 10^{14}$ g expiring today. PBHs are candidate progenitors of unidentified Gamma-Ray Bursts (GRBs) that lack X-ray afterglow. We propose spectral lag, which is the temporal delay between the high and low energy pulses, as an efficient method to identify PBH evaporation events with the Fermi Large Area Telescope (LAT).

T. N. Ukwatta; Jane H. MacGibbon; W. C. Parke; K. S. Dhuga; S. Rhodes; A. Eskandarian; N. Gehrels; L. Maximon; D. C. Morris

2010-03-23T23:59:59.000Z

366

Interim Control Strategy for the Test Area North/Technical Support Facility Sewage Treatment Facility Disposal Pond - Two-year Update  

SciTech Connect (OSTI)

The Idaho Cleanup Project has prepared this interim control strategy for the U.S. Department of Energy Idaho Operations Office pursuant to DOE Order 5400.5, Chapter 11.3e (1) to support continued discharges to the Test Area North/Technical Support Facility Sewage Treatment Facility Disposal Pond. In compliance with DOE Order 5400.5, a 2-year review of the Interim Control Strategy document has been completed. This submittal documents the required review of the April 2005 Interim Control Strategy. The Idaho Cleanup Project's recommendation is unchanged from the original recommendation. The Interim Control Strategy evaluates three alternatives: (1) re-route the discharge outlet to an uncontaminated area of the TSF-07; (2) construct a new discharge pond; or (3) no action based on justification for continued use. Evaluation of Alternatives 1 and 2 are based on the estimated cost and implementation timeframe weighed against either alternative's minimal increase in protection of workers, the public, and the environment. Evaluation of Alternative 3, continued use of the TSF-07 Disposal Pond under current effluent controls, is based on an analysis of four points: - Record of Decision controls will protect workers and the public - Risk of increased contamination is low - Discharge water will be eliminated in the foreseeable future - Risk of contamination spread is acceptable. The Idaho Cleanup Project recommends Alternative 3, no action other than continued implementation of existing controls and continued deactivation, decontamination, and dismantlement efforts at the Test Area North/Technical Support Facility.

L. V. Street

2007-04-01T23:59:59.000Z

367

RADIATION DOSE ASSESSMENT FOR THE BIOTA OF TERRESTRIAL ECOSYSTEMS IN THE SHORELINE ZONE OF THE CHERNOBYL NUCLEAR POWER PLANT COOLING POND  

SciTech Connect (OSTI)

Radiation exposure of the biota in the shoreline area of the Chernobyl Nuclear Power Plant Cooling Pond was assessed to evaluate radiological consequences from the decommissioning of the Cooling Pond. The article addresses studies of radioactive contamination of the terrestrial faunal complex and radionuclide concentration ratios in bodies of small birds, small mammals, amphibians, and reptiles living in the area. The data were used to calculate doses to biota using the ERICA Tool software. Doses from {sup 90}Sr and {sup 137}Cs were calculated using the default parameters of the ERICA Tool and were shown to be consistent with biota doses calculated from the field data. However, the ERICA dose calculations for plutonium isotopes were much higher (2-5 times for small mammals and 10-14 times for birds) than the doses calculated using the experimental data. Currently, the total doses for the terrestrial biota do not exceed maximum recommended levels. However, if the Cooling Pond is allowed to drawdown naturally and the contaminants of the bottom sediments are exposed and enter the biological cycle, the calculated doses to biota may exceed the maximum recommended values. The study is important in establishing the current exposure conditions such that a baseline exists from which changes can be documented following the lowering of the reservoir water. Additionally, the study provided useful radioecological data on biota concentration ratios for some species that are poorly represented in the literature.

Farfan, E.; Jannik, T.

2011-10-01T23:59:59.000Z

368

Utility Lines and Facilities (Montana)  

Broader source: Energy.gov [DOE]

These regulations apply to the construction of utility and power lines and facilities. They address the use of public right-of-ways for such construction, underground power lines, and construction...

369

Technology for the Recovery of Fuel and Adsorbent Carbons from Coal Burning Utility Ash Ponds and Landfills  

SciTech Connect (OSTI)

Several sampling techniques were evaluated to recover representative core samples from the ash ponds at Western Kentucky Energy's Coleman Station. The most successful was a combination of continuous-flight augers and specially designed soft-sediment sampling tubes driven by a Hammerhead drill mounted on an amphibious ARGO vehicle. A total of 51 core samples were recovered and analyzed in 3 ft sections and it was determined that there are 1,354,974 tons of ash in Pond C. Of the over 1.35M tons of ash present, 14% or 190K tons can be considered as coarse (+100 mesh). Pond C contains approximately 88K tons of carbon, nearly half of which is coarse and potentially recoverable with spiral concentration while the fine carbon (-100 mesh) is recoverable with froth flotation. There are 1.27M tons of carbon-free ash, 12% of which is coarse and potentially usable as block sand. Spiral concentration testing on bulk samples showed that product grade of 30 to 38% C (4200 to 5500 Btu/lb) was obtainable. When this product was cleaned again in an additional stage of spiral concentration, the product grade was improved to 7200 to 8200 Btu/lb with an accompanying 13 to 29% decrease in yield. Release analysis of hydraulically classified pond ash showed that froth flotation could provide froth products with as high a grade as 9000 Btu/lb with a yield of 5%. Increasing yield to 10% reduced froth grade to 7000 Btu/lb. Batch flotation provided froth grades as high as 6500 Btu/lb with yields of 7% with 1.5 lb/ton SPP and 1 lb/ton frother. Column flotation test results were similar to those achieved in batch flotation in terms of both grade and yield, however, carbon recoveries were lower (<70%). High airflow rate was required to achieve >50% carbon recovery and using wash water improved froth grade. Bottom ash samples were recovered from each of the units at Coleman Station. Characterization confirmed that sufficient quantity and quality of material is generated to produce a marketable lightweight aggregate and recover a high-grade fuel product. Spiral concentration provided acceptable grade lightweight aggregate with yields of only 10 to 20%. Incorporating a sieve bend into the process to recover coarse, porous ash particles from the outside race of the spirals increased aggregate yield to as high as 75%, however, the carbon content of the aggregate also increased. An opening size of 28 mesh on the sieve bend appeared to be sufficient. Lightweight concrete blocks (28 to 32 lbs) were produced from bottom ash and results show that acceptable strength could be attained with a cement/concrete ratio as low as 1/4. A mobile Proof-of-Concept (POC) field unit was designed and fabricated to meet the processing objectives of the project. The POC plant consisted of two trailer-mounted modules and was completely self sufficient with respect to power and water requirements. The POC unit was hauled to Coleman Station and operated at a feed rate of 2 tph. Results showed that the spirals operated similarly to previous pilot-scale operations and a 500 lb composite sample of coarse carbon was collected with a grade of 51.7% C or 7279 Btu/lb. Flotation results compared favorably with release analysis and 500 lbs of composite froth product was collected with a grade of 35% C or 4925 Btu/lb. The froth product was dewatered to 39% moisture with vacuum filtration. Pan pelletization and briquetting were evaluated as a means of minimizing handling concerns. Rotary pan pelletization produced uniform pellets with a compressive strength of 4 lbf without the use of any binder. Briquettes were produced by blending the coarse and fine carbon products at a ratio of 1:10, which is the proportion that the two products would be produced in a commercial operation. Using 3% lime as a binder produced the most desirable briquettes with respect to strength, attrition and drop testing. Additionally, the POC carbon products compared favorably with commercial activated carbon when used for removal of mercury from simulated flue gas. A business model was generated to summarize anti

J.G. Groppo; T.L. Robl

2005-09-30T23:59:59.000Z

370

Effects of Prudhoe Bay reserve pit fluids on water quality and macroinvertebrates of arctic tundra ponds in Alaska  

SciTech Connect (OSTI)

The report summarizes results from the authors` 1983 field study. Although the report should be useful in assessing impacts from reserve pit fluids under Arctic conditions and in evaluating possible management strategies, it was neither intended as an exhaustive study, nor can the results be wholly extrapolated to present-day oil field practices. Since 1983, state regulations concerning reserve pit fluid discharges have become increasingly stringent. Also, some industry practices have changed. For example, chrome lignosulfonate drill muds have been partly replaced by non-chrome lignosulfonates, and diesel oil has been largely replaced with less toxic mineral oil in drilling operations. From 1985 to 1987, the Fish and Wildlife Service began additional studies on Prudhoe Bay reserve pit fluids to examine impacts to tundra pond water, sediment, and biota; to evaluate acute and chronic toxicity through bioassays; and to examine bio-uptake of metals and hygrocarbons by resident species--including invertebrates, sedges, fish, and birds. Reports on these investigations have not yet been prepared, but should also be consulted by the interested reader when they become available.

West, R.L.; Snyder-Conn, E.

1987-09-01T23:59:59.000Z

371

Coronal emission lines as thermometers  

E-Print Network [OSTI]

Coronal emission line intensities are commonly used to measure electron temperatures using emission measure and/or line ratio methods. In the presence of systematic errors in atomic excitation calculations and data noise, the information on underlying temperature distributions is fundamentally limited. Increasing the number of emission lines used does not necessarily improve the ability to discriminate between different kinds of temperature distributions.

Judge, Philip G

2009-01-01T23:59:59.000Z

372

New developments in plasma-activated high-rate EB evaporation for metal strip  

SciTech Connect (OSTI)

The coating of metal strips by EB evaporation is well known since many years. But up to now the application on an industrial scale is very limited. One of the reasons are the costs and the progress of ECD technologies in the last ten years. But there are opportunities for the evaporation technology if layers with new properties can be produced. One way to meet this target is the application of a plasma-activated and ion-assisted process. However, the plasma density and the ion current density on the substrate must fit the high deposition rates. Many efforts in our institute are dedicated to the development of appropriate plasma sources. The systems are explained and main parameters are given. Using a plasma the layer properties can be improved remarkably. Therefore new applications come into play. First results are shown. Layers consisting of compounds will play a growing role for corrosion and abrasion protection. The technologies are explained and important film properties are presented.

Schiller, S.; Goedicke, K.; Hoetzsch, G. [Fraunhofer Institute, Dresden (Germany)

1994-12-31T23:59:59.000Z

373

Evaporative CO$_2$ microchannel cooling for the LHCb VELO pixel upgrade  

E-Print Network [OSTI]

The LHCb Vertex Detector (VELO) will be upgraded in 2018 to a lightweight pixel detector capable of 40 MHz readout and operation in very close proximity to the LHC beams. The thermal management of the system will be provided by evaporative CO$_2$ circulating in microchannels embedded within thin silicon plates. This solution has been selected due to the excellent thermal efficiency, the absence of thermal expansion mismatch with silicon ASICs and sensors, the radiation hardness of CO$_2$, and very low contribution to the material budget. Although microchannel cooling is gaining considerable attention for applications related to microelectronics, it is still a novel technology for particle physics experiments, in particular when combined with evaporative CO$_2$ cooling. The R&D effort for LHCb is focused on the design and layout of the channels together with a fluidic connector and its attachment which must withstand pressures up to 170 bar. Even distribution of the coolant is ensured by means of the use o...

de Aguiar Francisco, Oscar A; Collins, Paula; Dumps, Raphael; John, Malcolm; Mapelli, Alessandro; Romagnoli, Giulia

2015-01-01T23:59:59.000Z

374

TANK 26F SUPERNATANT AND 2F EVAPORATOR EDUCTOR PUMP SAMPLE CHARACTERIZATION RESULTS  

SciTech Connect (OSTI)

In an effort to understand the reasons for system plugging problems in the SRS 2F evaporator, supernatant samples were retrieved from the evaporator feed tank (Tank 26F) and solids were collected from the evaporator eductor feed pump for characterization. The variable depth supernatant samples were retrieved from Tank 26F in early December of 2010 and samples were provided to SRNL and the F/H Area laboratories for analysis. Inspection and analysis of the samples at SRNL was initiated in early March of 2011. During the interim period, samples were frequently exposed to temperatures as low as 12 C with daily temperature fluctuations as high as 10 C. The temperature at the time of sample collection from the waste tank was 51 C. Upon opening the supernatant bottles at SRNL, many brown solids were observed in both of the Tank 26F supernatant samples. In contrast, no solids were observed in the supernatant samples sent to the F/H Area laboratories, where the analysis was completed within a few days after receipt. Based on these results, it is believed that the original Tank 26F supernatant samples did not contain solids, but solids formed during the interim period while samples were stored at ambient temperature in the SRNL shielded cells without direct climate control. Many insoluble solids (>11 wt. % for one sample) were observed in the Tank 26F supernatant samples after three months of storage at SRNL which would not dissolve in the supernatant solution in two days at 51 C. Characterization of these solids along with the eductor pump solids revealed the presence of sodium oxalate and clarkeite (uranyl oxyhydroxide) as major crystalline phases. Sodium nitrate was the dominant crystalline phase present in the unwashed Eductor Pump solids. Crystalline sodium nitrate may have formed during the drying of the solids after filtration or may have been formed in the Tank 26F supernatant during storage since the solution was found to be very concentrated (9-12 M Na{sup +}). Concentrated mineral acids and elevated temperature were required to dissolve all of these solids. The refractory nature of some of the solids is consistent with the presence of metal oxides such as aluminosilicates (observed as a minor phase by XRD). Characterization of the water wash solutions and the digested solids confirmed the presence of oxalate salts in both solid samples. Sulfate enrichment was also observed in the Tank 26F solids wash solution, indicating the presence of sulfate precipitates such as burkeite. OLI modeling of the Tank 26F filtered supernatant composition revealed that sodium oxalate has a very low solubility in this solution. The model predicts that the sodium oxalate solubility in the Tank 26F supernatant is only 0.0011 M at 50 C. The results indicate that the highly concentrated nature of the evaporator feed solution and the addition of oxalate anion to the waste stream each contribute to the formation of insoluble solids in the 2F evaporator system.

King, W.; Hay, M.; Coleman, C.

2011-08-23T23:59:59.000Z

375

Interpretation of time-of-flight distributions for neutral particles under pulsed laser evaporation using direct Monte Carlo simulation  

SciTech Connect (OSTI)

A theoretical study of the time-of-flight (TOF) distributions under pulsed laser evaporation in vacuum has been performed. A database of TOF distributions has been calculated by the direct simulation Monte Carlo (DSMC) method. It is shown that describing experimental TOF signals through the use of the calculated TOF database combined with a simple analysis of evaporation allows determining the irradiated surface temperature and the rate of evaporation. Analysis of experimental TOF distributions under laser ablation of niobium, copper, and graphite has been performed, with the evaluated surface temperature being well agreed with results of the thermal model calculations. General empirical dependences are proposed, which allow indentifying the regime of the laser induced thermal ablation from the TOF distributions for neutral particles without invoking the DSMC-calculated database.

Morozov, Alexey A., E-mail: morozov@itp.nsc.ru [Institute of Thermophysics SB RAS, 1 Lavrentyev Ave., 630090 Novosibirsk (Russian Federation)

2013-12-21T23:59:59.000Z

376

The dark matter self-interaction and its impact on the critical mass for dark matter evaporations inside the sun  

E-Print Network [OSTI]

We study the capture, annihilation and evaporation of dark matter (DM) inside the Sun. It has been shown that the DM self-interaction can increase the DM number inside the Sun. We demonstrate that this enhancement becomes more significant in the regime of small DM mass, given a fixed DM self-interaction cross section. This leads to the enhancement of neutrino flux from DM annihilation. On the other hand, for DM mass as low as as a few GeVs, not only the DM-nuclei scatterings can cause the DM evaporation, DM self-interaction also provides non-negligible contributions to this effect. Consequently, the critical mass for DM evaporation (typically 3 ~ 4 GeV without the DM self-interaction) can be slightly increased. We discuss the prospect of detecting DM self-interaction in IceCube- PINGU using the annihilation channels $\\chi\\chi\\rightarrow\

Chian-Shu Chen; Fei-Fan Lee; Guey-Lin Lin; Yen-Hsun Lin

2014-12-21T23:59:59.000Z

377

Instabilities and Anti-Evaporation of Reissner-Nordstrm Black Holes in modified $F(R)$ gravity  

E-Print Network [OSTI]

We study the instabilities and related anti-evaporation of the extremal Reissner-Nordstr\\"om (RN) black hole in $F(R)$ gravity. It is remarkable that the effective electric charge can be generated for some solutions of $F(R)$ gravity without electromagnetic field. The anti-evaporation effect occurs but it emerges only in the strong coupling limit of the effective gravitational coupling. The instabilities of RN black hole are also investigated when the electromagnetic sector is added to the action of $F(R)$ gravity. We show the anti-evaporation occurs in the Maxwell-$F(R)$ gravity with the arbitrary gravitational coupling constant although it does not occur in the Maxwell-Einstein gravity. Furthermore, general spherically-symmetric solution of $F(R)$ gravity in the Einstein frame is obtained.

Shin'ichi Nojiri; Sergei D. Odintsov

2014-10-05T23:59:59.000Z

378

Evaporation-assisted high-power impulse magnetron sputtering: The deposition of tungsten oxide as a case study  

SciTech Connect (OSTI)

The deposition rate during the synthesis of tungsten trioxide thin films by reactive high-power impulse magnetron sputtering (HiPIMS) of a tungsten target increases, above the dc threshold, as a result of the appropriate combination of the target voltage, the pulse duration, and the amount of oxygen in the reactive atmosphere. This behavior is likely to be caused by the evaporation of the low melting point tungsten trioxide layer covering the metallic target in such working conditions. The HiPIMS process is therefore assisted by thermal evaporation of the target material.

Hemberg, Axel; Dauchot, Jean-Pierre; Snyders, Rony; Konstantinidis, Stephanos [Materia Nova Research Center-Parc Initialis, 1, Avenue Copernic, B-7000 Mons, Belgium and Chimie des Interactions Plasma-Surface, CIRMAP, Universite de Mons-20, Place du Parc, B-7000 Mons (Belgium); Chimie des Interactions Plasma-Surface, CIRMAP, Universite de Mons-20, Place du Parc, B-7000 Mons (Belgium); Materia Nova Research Center-Parc Initialis, 1, Avenue Copernic, B-7000 Mons (Belgium) and Chimie des Interactions Plasma-Surface, CIRMAP, Universite de Mons-20, Place du Parc, B-7000 Mons (Belgium); Chimie des Interactions Plasma-Surface, CIRMAP, Universite de Mons-20, Place du Parc, B-7000 Mons (Belgium)

2012-07-15T23:59:59.000Z

379

Desiccant Enhanced Evaporative Air-Conditioning (DEVap): Evaluation of a New Concept in Ultra Efficient Air Conditioning  

SciTech Connect (OSTI)

NREL has developed the novel concept of a desiccant enhanced evaporative air conditioner (DEVap) with the objective of combining the benefits of liquid desiccant and evaporative cooling technologies into an innovative 'cooling core.' Liquid desiccant technologies have extraordinary dehumidification potential, but require an efficient cooling sink. DEVap's thermodynamic potential overcomes many shortcomings of standard refrigeration-based direct expansion cooling. DEVap decouples cooling and dehumidification performance, which results in independent temperature and humidity control. The energy input is largely switched away from electricity to low-grade thermal energy that can be sourced from fuels such as natural gas, waste heat, solar, or biofuels.

Kozubal, E.; Woods, J.; Burch, J.; Boranian, A.; Merrigan, T.

2011-01-01T23:59:59.000Z

380

Silicon dioxide and hafnium dioxide evaporation characteristics from a high-frequency sweep e-beam system  

SciTech Connect (OSTI)

Reactive oxygen evaporation characteristics were determined as a function of the front-panel control parameters provided by a programmable, high-frequency sweep e-beam system. An experimental design strategy used deposition rate, beam speed, pattern, azimuthal rotation speed, and dwell time as the variables. The optimal settings for obtaining a broad thickness distribution, efficient silicon dioxide boule consumption, and minimal hafnium dioxide defect density were generated. The experimental design analysis showed the compromises involved with evaporating these oxides. {copyright} {ital 1996 Optical Society of America.}

Chow, R. [Lawrence Livermore National Laboratory, Livermore, California 94551-0808 (United States); Tsujimoto, N. [MDC Vacuum Products Corporation, Hayward, California 94545 (United States)

1996-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "lined evaporation pond" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Recycled Water Reuse Permit Renewal Application for the Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond  

SciTech Connect (OSTI)

ABSTRACT This renewal application for the Industrial Wastewater Reuse Permit (IWRP) WRU-I-0160-01 at Idaho National Laboratory (INL), Materials and Fuels Complex (MFC) Industrial Waste Ditch (IWD) and Industrial Waste Pond (IWP) is being submitted to the State of Idaho, Department of Environmental Quality (DEQ). This application has been prepared in compliance with the requirements in IDAPA 58.01.17, Recycled Water Rules. Information in this application is consistent with the IDAPA 58.01.17 rules, pre-application meeting, and the Guidance for Reclamation and Reuse of Municipal and Industrial Wastewater (September 2007). This application is being submitted using much of the same information contained in the initial permit application, submitted in 2007, and modification, in 2012. There have been no significant changes to the information and operations covered in the existing IWRP. Summary of the monitoring results and operation activity that has occurred since the issuance of the WRP has been included. MFC has operated the IWP and IWD as regulated wastewater land treatment facilities in compliance with the IDAPA 58.01.17 regulations and the IWRP. Industrial wastewater, consisting primarily of continuous discharges of nonhazardous, nonradioactive, routinely discharged noncontact cooling water and steam condensate, periodic discharges of industrial wastewater from the MFC facility process holdup tanks, and precipitation runoff, are discharged to the IWP and IWD system from various MFC facilities. Wastewater goes to the IWP and IWD with a permitted annual flow of up to 17 million gallons/year. All requirements of the IWRP are being met. The Operations and Maintenance Manual for the Industrial Wastewater System will be updated to include any new requirements.

No Name

2014-10-01T23:59:59.000Z

382

REPORT ON THE ANALYSIS OF WAC SAMPLES FROM EVAPORATOR OVERHEADS FOR 2011  

SciTech Connect (OSTI)

This report tabulates the chemical analysis of the 3H, 2H and 2F evaporator overhead samples including the inorganic, organic, and radionuclide species according the ETP WAC (rev.4). In addition, the physical properties including pH, total suspended solids, and average particle size are listed for each sample. The report identifies all sample receipt dates, preparation methods, and analyses completed to accumulate these values. All values were found to be within the ETP WAC specifications for WWCT except for the {sup 137}Cs concentration for the 2F sample which was slightly above the limit ({approx}5%). However, tank farm personnel sample each tank overhead for beta/gamma prior to transfer using a pulse height analyzer and these field readings were all well within limits. Additional actions will be taken to help understand the reason in the discrepancy of the field measurement versus laboratory analysis.

Washington, A.

2012-03-29T23:59:59.000Z

383

Indirect evaporative cooler using membrane-contained, liquid desiccant for dehumidification  

DOE Patents [OSTI]

An indirect evaporative cooler for cooling inlet supply air from a first temperature to a second, lower temperature using a stream of liquid coolant and a stream of exhaust or purge air. The cooler includes a first flow channel for inlet supply air and a second flow channel adjacent the first for exhaust air. The first and second flow channels are defined in part by sheets of a membrane permeable to water vapor such that mass is transferred as a vapor through the membrane from the inlet supply air to a contained liquid desiccant for dehumidification and also to the exhaust air as heat is transferred from the inlet supply air to the liquid coolant. A separation wall divides the liquid desiccant and the coolant but allows heat to be transferred from the supply air to the coolant which releases water vapor to the counter or cross flowing exhaust air.

Kozubal, Eric Joseph; Slayzak, Steven Joseph

2014-07-08T23:59:59.000Z

384

Evaporative CO2 cooling using microchannels etched in silicon for the future LHCb vertex detector  

E-Print Network [OSTI]

The extreme radiation dose received by vertex detectors at the Large Hadron Collider dictates stringent requirements on their cooling systems. To be robust against radiation damage, sensors should be maintained below -20 degree C and at the same time, the considerable heat load generated in the readout chips and the sensors must be removed. Evaporative CO2 cooling using microchannels etched in a silicon plane in thermal contact with the readout chips is an attractive option. In this paper, we present the first results of microchannel prototypes with circulating, two-phase CO2 and compare them to simulations. We also discuss a practical design of upgraded VELO detector for the LHCb experiment employing this approach.

A. Nomerotski; J. Buytart; P. Collins; R. Dumps; E. Greening; M. John; A. Mapelli; A. Leflat; Y. Li; G. Romagnoli; B. Verlaat

2013-02-16T23:59:59.000Z

385

Preparation and characterization of indium zinc oxide thin films by electron beam evaporation technique  

SciTech Connect (OSTI)

In this work, the preparation of In{sub 2}O{sub 3}-ZnO thin films by electron beam evaporation technique on glass substrates is reported. Optical and electrical properties of these films were investigated. The effect of dopant amount and annealing temperature on the optical and electrical properties of In{sub 2}O{sub 3}-ZnO thin films was also studied. Different amount of ZnO was used as dopant and the films were annealed at different temperature. The results showed that the most crystalline, transparent and uniform films with lowest resistivity were obtained using 25 wt% of ZnO annealed at 500 {sup o}C.

Keshavarzi, Reza [Chemistry Department, Catalysis Division, University of Isfahan, Isfahan 81746-73441 (Iran, Islamic Republic of)] [Chemistry Department, Catalysis Division, University of Isfahan, Isfahan 81746-73441 (Iran, Islamic Republic of); Mirkhani, Valiollah, E-mail: mirkhani@sci.ui.ac.ir [Chemistry Department, Catalysis Division, University of Isfahan, Isfahan 81746-73441 (Iran, Islamic Republic of)] [Chemistry Department, Catalysis Division, University of Isfahan, Isfahan 81746-73441 (Iran, Islamic Republic of); Moghadam, Majid, E-mail: moghadamm@sci.ui.ac.ir [Chemistry Department, Catalysis Division, University of Isfahan, Isfahan 81746-73441 (Iran, Islamic Republic of) [Chemistry Department, Catalysis Division, University of Isfahan, Isfahan 81746-73441 (Iran, Islamic Republic of); Department of Nanotechnology Engineering, University of Isfahan, Isfahan 81746-73441 (Iran, Islamic Republic of); Tangestaninejad, Shahram; Mohammadpoor-Baltork, Iraj [Chemistry Department, Catalysis Division, University of Isfahan, Isfahan 81746-73441 (Iran, Islamic Republic of)] [Chemistry Department, Catalysis Division, University of Isfahan, Isfahan 81746-73441 (Iran, Islamic Republic of); Fallah, Hamid Reza; Dastjerdi, Mohammad Javad Vahid; Modayemzadeh, Hamed Reza [Department of Physics, University of Isfahan, Isfahan 81746-73441 (Iran, Islamic Republic of)] [Department of Physics, University of Isfahan, Isfahan 81746-73441 (Iran, Islamic Republic of)

2011-04-15T23:59:59.000Z

386

Light charged particle evaporation from hot ${31}^$P nucleus at E$^*$ ~ 60 MeV  

E-Print Network [OSTI]

The energy spectra of evaporated light charged particles (LCP) $\\alpha$, p, d and t have been measured in $7^$Li(47 MeV) + ${24}^$Mg and ${19}^$F(96 MeV)+ ${12}^$C reactions. Both the systems populate the same compound nucleus ${31}^$F at excitation energy E$^*$ ~ 60 MeV. It has been observed that the light particle spectra obtained in Li + Mg reaction follow standard statistical model prediction, whereas a deformed configuration of the compound nucleus is needed to explain the LCP spectra for F + C reaction, which has been attributed to the effect of larger input angular momentum in the case of ${19}^$F(96 MeV)+ ${12}^$C system.

D. Bandyopadhyay; C. Bhattacharya; K. Krishan; S. Bhattacharya; S. K. Basu; A. Chatterjee; S. Kailas; A. Srivastava; K. Mahata

2002-02-12T23:59:59.000Z

387

Development of fluorocarbon evaporative cooling recirculators and controls for the ATLAS inner silicon tracker  

E-Print Network [OSTI]

We report on the development of evaporative fluorocarbon cooling recirculators and their control systems for the ATLAS inner silicon tracker. We have developed a prototype circulator using a dry, hermetic compressor with C/sub 3/F/sup 8/ refrigerant, and have prototyped the remote-control analog pneumatic links for the regulation of coolant mass flows and operating temperatures that will be necessary in the magnetic field and radiation environment around ATLAS. pressure and flow measurement and control use 150+ channels of standard ATLAS LMB ("Local Monitor Board") DAQ and DACs on a multi-drop CAN network administered through a BridgeVIEW user interface. A hardwired thermal interlock system has been developed to cut power to individual silicon modules should their temperatures exceed safe values. Highly satisfactory performance of the circulator under steady state, partial-load and transient conditions was seen, with proportional fluid flow tuned to varying circuit power. Future developments, including a 6 kW...

Bayer, C; Bonneau, P; Bosteels, Michel; Burckhart, H J; Cragg, D; English, R; Hallewell, G D; Hallgren, Bjrn I; Ilie, S; Kersten, S; Kind, P; Langedrag, K; Lindsay, S; Merkel, M; Stapnes, Steinar; Thadome, J; Vacek, V

2000-01-01T23:59:59.000Z

388

Bipolar pulse forming line  

DOE Patents [OSTI]

A bipolar pulse forming transmission line module for linear induction accelerators having first, second, third, fourth, and fifth planar conductors which form an interleaved stack with dielectric layers between the conductors. Each conductor has a first end, and a second end adjacent an acceleration axis. The first and second planar conductors are connected to each other at the second ends, the fourth and fifth planar conductors are connected to each other at the second ends, and the first and fifth planar conductors are connected to each other at the first ends via a shorting plate adjacent the first ends. The third planar conductor is electrically connectable to a high voltage source, and an internal switch functions to short a high voltage from the first end of the third planar conductor to the first end of the fourth planar conductor to produce a bipolar pulse at the acceleration axis with a zero net time integral. Improved access to the switch is enabled by an aperture through the shorting plate and the proximity of the aperture to the switch.

Rhodes, Mark A. (Pleasanton, CA)

2008-10-21T23:59:59.000Z

389

Shaping the Globular Cluster Mass Function by Stellar-Dynamical Evaporation  

E-Print Network [OSTI]

We show that the globular cluster mass function (GCMF) in the Milky Way depends on cluster half-mass density (rho_h) in the sense that the turnover mass M_TO increases with rho_h while the width of the GCMF decreases. We argue that this is the expected signature of the slow erosion of a mass function that initially rose towards low masses, predominantly through cluster evaporation driven by internal two-body relaxation. We find excellent agreement between the observed GCMF -- including its dependence on internal density rho_h, central concentration c, and Galactocentric distance r_gc -- and a simple model in which the relaxation-driven mass-loss rates of clusters are approximated by -dM/dt = mu_ev ~ rho_h^{1/2}. In particular, we recover the well-known insensitivity of M_TO to r_gc. This feature does not derive from a literal ``universality'' of the GCMF turnover mass, but rather from a significant variation of M_TO with rho_h -- the expected outcome of relaxation-driven cluster disruption -- plus significant scatter in rho_h as a function of r_gc. Our conclusions are the same if the evaporation rates are assumed to depend instead on the mean volume or surface densities of clusters inside their tidal radii, as mu_ev ~ rho_t^{1/2} or mu_ev ~ Sigma_t^{3/4} -- alternative prescriptions that are physically motivated but involve cluster properties (rho_t and Sigma_t) that are not as well defined or as readily observable as rho_h. In all cases, the normalization of mu_ev required to fit the GCMF implies cluster lifetimes that are within the range of standard values (although falling towards the low end of this range). Our analysis does not depend on any assumptions or information about velocity anisotropy in the globular cluster system.

Dean E. McLaughlin; S. Michael Fall

2008-06-11T23:59:59.000Z

390

Heat capacity of quantum adsorbates: Hydrogen and helium on evaporated gold films  

SciTech Connect (OSTI)

The author has constructed an apparatus to make specific heat measurements of quantum gases adsorbed on metallic films at temperatures between 0.3 and 4 K. He has used this apparatus to study quench-condensed hydrogen films between 4 and 923 layers thick with J = 1 concentrations between 0.28 and 0.75 deposited on an evaporated gold surface. He has observed that the orientational ordering of the J = 1 molecules depends on the substrate temperature during deposition of the hydrogen film. He has inferred that the density of the films condensed at the lowest temperatures is 25% higher than in bulk H{sub 2} crystals and have observed that the structure of those films is affected by annealing at 3.4 K. The author has measured the J = 1 to J = 0 conversion rate to be comparable to that of the bulk for thick films; however, he found evidence that the gold surface catalyzes conversion in the first two to four layers. He has also used this apparatus to study films of {sup 4}He less than one layer thick adsorbed on an evaporated gold surface. He shows that the phase diagram of the system is similar to that for {sup 4}He/graphite although not as rich in structure, and the phase boundaries occur at different coverages and temperatures. At coverages below about half a layer and at sufficiently high temperatures, the {sup 4}He behaves like a two-dimensional noninteracting Bose gas. At lower temperatures and higher coverages, liquidlike and solidlike behavior is observed. The Appendix shows measurements of the far-infrared absorptivity of the high-{Tc} superconductor La{sub 1.87}Sr{sub 0.13}CuO{sub 4}.

Birmingham, J.T. [Univ. of California, Berkeley, CA (United States). Dept. of Physics]|[Lawrence Berkeley National Lab., CA (United States). Materials Sciences Div.

1996-06-01T23:59:59.000Z

391

AC microcalorimetry of adsorbates on evaporated metal films: Orientational ordering of H sub 2 multilayers  

SciTech Connect (OSTI)

We have improved and extended a novel ac calorimetric technique for measuring the heat capacity of adsorbates on evaporated metal films. Metallic substrates are of particular interest in current studies of the thermodynamics of adsorbed molecules. The method described in the present work is only calorimetric technique which allows measurements of molecules on simple metallic surfaces. Among other improvements, we have achieved significant progress in the preparation and characterization of the evaporated metal film. We have applied this novel technique to a study of hydrogen multilayers on gold and sapphire substrates. We have shown that samples of normal-hydrogen with a nominal coverage n of approximately 25 monolayers (ML) undergo a bulk-like orientational ordering transition. The transition is suppressed as the coverage is decreased, and no sign of the transition remains above 1.6 K for n {approx} 1 ML. For n {approx lt} 8 ML, the peak in the heat capacity exhibits signs of finite-size effects. At higher coverages, finite-size effects are not observed, and the shape of the peak depends strongly on the substrate. We conclude that the peak is inhomogeneously broadened for n {approx lt} 8 ML. This work represents the first measurements of the heat capacity due to orientational ordering in adsorbed hydrogen. The results of an earlier experiment involving vibrational spectroscopy of adsorbed molecules are included in the Appendix. In this work, we have used infrared emission spectroscopy to study the spectral region in the vicinity of the C=O stretch vibration of bridge-bonded CO on Pt(111).

Phelps, R.B.

1991-11-01T23:59:59.000Z

392

AC microcalorimetry of adsorbates on evaporated metal films: Orientational ordering of H{sub 2} multilayers  

SciTech Connect (OSTI)

We have improved and extended a novel ac calorimetric technique for measuring the heat capacity of adsorbates on evaporated metal films. Metallic substrates are of particular interest in current studies of the thermodynamics of adsorbed molecules. The method described in the present work is only calorimetric technique which allows measurements of molecules on simple metallic surfaces. Among other improvements, we have achieved significant progress in the preparation and characterization of the evaporated metal film. We have applied this novel technique to a study of hydrogen multilayers on gold and sapphire substrates. We have shown that samples of normal-hydrogen with a nominal coverage n of approximately 25 monolayers (ML) undergo a bulk-like orientational ordering transition. The transition is suppressed as the coverage is decreased, and no sign of the transition remains above 1.6 K for n {approx} 1 ML. For n {approx_lt} 8 ML, the peak in the heat capacity exhibits signs of finite-size effects. At higher coverages, finite-size effects are not observed, and the shape of the peak depends strongly on the substrate. We conclude that the peak is inhomogeneously broadened for n {approx_lt} 8 ML. This work represents the first measurements of the heat capacity due to orientational ordering in adsorbed hydrogen. The results of an earlier experiment involving vibrational spectroscopy of adsorbed molecules are included in the Appendix. In this work, we have used infrared emission spectroscopy to study the spectral region in the vicinity of the C=O stretch vibration of bridge-bonded CO on Pt(111).

Phelps, R.B.

1991-11-01T23:59:59.000Z

393

NETL LINES OF DEMARCATION 09282012  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

LINES OF DEMARCATION September 28, 2012 Contact: Site Operations Division or ESS&H Division with Questions The oversight, upkeep, and segregation of NETL infrastructure components,...

394

Corrective Action Investigation Plan for Corrective Action Unit 552: Area 12 Muckpile and Ponds, Nevada Test Site, Nevada, Rev. No.: 1 with ROTC 1 and 2  

SciTech Connect (OSTI)

This Corrective Action Investigation Plan (CAIP) contains project-specific information including facility descriptions, environmental sample collection objectives, and criteria for conducting site investigation activities at Corrective Action Unit (CAU) 552: Area 12 Muckpile and Ponds, Nevada Test Site (NTS), Nevada. This CAIP has been developed in accordance with the ''Federal Facility Agreement and Consent Order'' (FFACO) (1996) that was agreed to by the State of Nevada, the U.S. Department of Energy (DOE), and the U.S. Department of Defense. The NTS is approximately 65 miles (mi) northwest of Las Vegas, Nevada (Figure 1-1). Corrective Action Unit 552 is comprised of the one Corrective Action Site which is 12-23-05, Ponds. One additional CAS, 12-06-04, Muckpile (G-Tunnel Muckpile), was removed from this CAU when it was determined that the muckpile is an active site. A modification to the FFACO to remove CAS 12-06-04 was approved by the Nevada Division of Environmental Protection (NDEP) on December 16, 2004. The G-Tunnel ponds were first identified in the 1991 Reynolds Electrical & Engineering Co., Inc. document entitled, ''Nevada Test Site Inventory of Inactive and Abandoned Facilities and Waste Sites'' (REECo, 1991). Corrective Action Unit 552 is being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives. Therefore, additional information will be obtained by conducting a corrective action investigation (CAI) prior to evaluating and selecting the corrective action alternatives for the site. The CAI will include field inspections, radiological surveys, and sampling of appropriate media. Data will also be obtained to support investigation-derived waste (IDW) disposal and potential future waste management decisions.

David A. Strand

2005-01-01T23:59:59.000Z

395

Suitability of salt-gradient solar ponds for electrical power generation in the US Trust Territory of the Pacific Islands, Guam, and American Samoa  

SciTech Connect (OSTI)

The procedures and findings of a study to assess the suitability of salt-gradient solar ponds for base-load (firm) electricity generation in the US Trust Territory of the Pacific Islands (TTPI), Guam and American Samoa are described. The general conclusion is that solar pond power plants (SPPPs) are viable both technically and economically for some applications, possibly including atolls. The most practical immediate application would be to small and intermediate power users such as villages and airports. It is recommended that (1) at least one small SPPP be built immediately on a dry land site such as for the main village on Peleliu, Palau, (considered in this report) or at other identified feasible sites, and (2) that a design study be conducted to adapt the technology to atoll sites. This study was carried out by first reviewing all available literature on solar ponds and the regions concerned. All the regions in question were visited. Several sites were selected for specific study and SPPP conceptual designs were developed for these sites. These sites are (1) North Peleliu, Palau, with (2) Peleliu airport as an auxiliary site, (3) Aimeliik, Palau, and (4) atoll environments. Cultural, political, environmental and legal considerations were given equal weight with technical and economic factors, and locally resident persons were used as interpreters and liaisons. There exists strong support in the government and the community to develop these proposed site-specific SPPPs and land is available. Power needs were defined, construction and operation costs were calculated and performance was predicted for the site-specific designs. The results of the Palau site-specific studies were generalized to other areas and environments in the TTPI, Guam and American Samoa. An economic analysis of the SPPP conceptual design developed for Palau was made using the discounted cash flow method.

McCord, T.B.; Bathen, K.H.; Boesgaard, H.; Fanale, F.P.; McCord, C.S.; Scudder, R.J.; Weeks, D.D.; Yuen, J.W.L.

1982-11-01T23:59:59.000Z

396

High level waste storage tank farms/242-A evaporator Standards/Requirements Identification Document (S/RID), Volume 6  

SciTech Connect (OSTI)

The High-Level Waste Storage Tank Farms/242-A Evaporator Standards/Requirements Identification Document (S/RID) is contained in multiple volumes. This document (Volume 6) outlines the standards and requirements for the sections on: Environmental Restoration and Waste Management, Research and Development and Experimental Activities, and Nuclear Safety.

Not Available

1994-04-01T23:59:59.000Z

397

Modelling of heating and evaporation of n-Heptane droplets: Towards a generic model for fuel droplet/particle conversion  

E-Print Network [OSTI]

is a part of a project that is targeted to optimize the pyrolysis process of biomass pellets for bio, study of pyrolysis of the biomass pellets and evaporation of the pyrolysis bio-oil droplets are two key of the biomass pellets in the pyrolysis reactor, for the purpose of optimiz- ing the pyrolysis process. Modelling

Yin, Chungen

398

An evaporation test based on Thermal Infra Red Remote-Sensing to select appropriate soil hydraulic properties  

E-Print Network [OSTI]

An evaporation test based on Thermal Infra Red Remote- Sensing to select appropriate soil hydraulic to estimate common soil hydraulic properties at regional scale. Since they rely on an empirical link between at large scales. Here we propose a method for selecting appropriate soil hydraulic properties based

Paris-Sud XI, Universit de

399

Controlling the Texture and Crystallinity of Evaporated Lead Phthalocyanine Thin Films for Near-Infrared Sensitive Solar Cells  

E-Print Network [OSTI]

Controlling the Texture and Crystallinity of Evaporated Lead Phthalocyanine Thin Films for Near-Infrared Sensitive Solar Cells Karolien Vasseur,, Katharina Broch,§ Alexander L. Ayzner, Barry P. Rand, David Cheyns: To achieve organic solar cells with a broadened spectral absorption, we aim to promote the growth of the near

Schreiber, Frank

400

FULL SCALE TESTING TECHNOLOGY MATURATION OF A THIN FILM EVAPORATOR FOR HIGH-LEVEL LIQUID WASTE MANAGEMENT AT HANFORD - 12125  

SciTech Connect (OSTI)

Simulant testing of a full-scale thin-film evaporator system was conducted in 2011 for technology development at the Hanford tank farms. Test results met objectives of water removal rate, effluent quality, and operational evaluation. Dilute tank waste simulant, representing a typical double-shell tank supernatant liquid layer, was concentrated from a 1.1 specific gravity to approximately 1.5 using a 4.6 m{sup 2} (50 ft{sup 2}) heated transfer area Rototherm{reg_sign} evaporator from Artisan Industries. The condensed evaporator vapor stream was collected and sampled validating efficient separation of the water. An overall decontamination factor of 1.2E+06 was achieved demonstrating excellent retention of key radioactive species within the concentrated liquid stream. The evaporator system was supported by a modular steam supply, chiller, and control computer systems which would be typically implemented at the tank farms. Operation of these support systems demonstrated successful integration while identifying areas for efficiency improvement. Overall testing effort increased the maturation of this technology to support final deployment design and continued project implementation.

TEDESCHI AR; CORBETT JE; WILSON RA; LARKIN J

2012-01-26T23:59:59.000Z

Note: This page contains sample records for the topic "lined evaporation pond" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Influence of evaporative demand on aquaporin expression and root hydraulics of hybrid poplarpce_2331 1318..1331  

E-Print Network [OSTI]

Influence of evaporative demand on aquaporin expression and root hydraulics of hybrid poplarpce_2331 1318..1331 ADRIANA M. ALMEIDA-RODRIGUEZ, UWE G. HACKE & JOAN LAUR Department of Renewable (Y), allowing continued gas exchange in hybrid poplar (Populus trichocarpa ¥ deltoides) saplings

Hacke, Uwe

402

Influence of contact angle on slow evaporation in 2D porous media. H.Chrabi1,2  

E-Print Network [OSTI]

the invasion percolation model with the computation of the diffusive transport in the gas phase. The overall, cooperative smoothing mechanisms of the interface become important and the width of the liquid gas interface fingers that form during the evaporation process increases. The mean overall drying time increases

Boyer, Edmond

403

Dependence of recycling and edge profiles on lithium evaporation in high triangularity, high performance NSTX H-mode discharges  

E-Print Network [OSTI]

1 Dependence of recycling and edge profiles on lithium evaporation in high triangularity, high between discharges in NSTX, partly to reduce recycling. Reduced D emissions from the lower and upper of the recycling light, improvements in global confinement16-19 , along with the appearance of ELM-free regimes20

Princeton Plasma Physics Laboratory

404

High-level waste storage tank farms/242-A evaporator Standards/Requirements Identification Document (S/RID), Volume 4  

SciTech Connect (OSTI)

The High-Level Waste Storage Tank Farms/242-A Evaporator Standards/Requirements Identification Document (S/RID) is contained in multiple volumes. This document (Volume 4) presents the standards and requirements for the following sections: Radiation Protection and Operations.

Not Available

1994-04-01T23:59:59.000Z

405

PHYSICAL REVIEW A 87, 053417 (2013) Efficient direct evaporative cooling in an atom-chip magnetic trap  

E-Print Network [OSTI]

technique for achieving the low temperatures and high densities needed to produce Bose-Einstein condensates that slows down rethermalization and can reduce cooling efficiency to the point that condensation cannotPHYSICAL REVIEW A 87, 053417 (2013) Efficient direct evaporative cooling in an atom-chip magnetic

Du, Shengwang

406

High-level waste storage tank farms/242-A evaporator Standards/Requirements Identification Document (S/RID), Volume 2  

SciTech Connect (OSTI)

The High-Level Waste Storage Tank Farms/242-A Evaporator Standards/Requirements Document (S/RID) is contained in multiple volumes. This document (Volume 2) presents the standards and requirements for the following sections: Quality Assurance, Training and Qualification, Emergency Planning and Preparedness, and Construction.

Not Available

1994-04-01T23:59:59.000Z

407

A Novel Absorption Cycle for Combined Water Heating, Dehumidification, and Evaporative Cooling  

SciTech Connect (OSTI)

In this study, development of a novel system for combined water heating, dehumidification, and space evaporative cooling is discussed. Ambient water vapor is used as a working fluid in an open system. First, water vapor is absorbed from an air stream into an absorbent solution. The latent heat of absorption is transferred into the process water that cools the absorber. The solution is then regenerated in the desorber, where it is heated by a heating fluid. The water vapor generated in the desorber is condensed and its heat of phase change is transferred to the process water in the condenser. The condensed water can then be used in an evaporative cooling process to cool the dehumidified air exiting the absorber, or it can be drained if primarily dehumidification is desired. Essentially, this open absorption cycle collects space heat and transfers it to process water. This technology is enabled by a membrane-based absorption/desorption process in which the absorbent is constrained by hydrophobic vapor-permeable membranes. Constraining the absorbent film has enabled fabrication of the absorber and desorber in a plate-and-frame configuration. An air stream can flow against the membrane at high speed without entraining the absorbent, which is a challenge in conventional dehumidifiers. Furthermore, the absorption and desorption rates of an absorbent constrained by a membrane are greatly enhanced. Isfahani and Moghaddam (Int. J. Heat Mass Transfer, 2013) demonstrated absorption rates of up to 0.008 kg/m2s in a membrane-based absorber and Isfahani et al. (Int. J. Multiphase Flow, 2013) have reported a desorption rate of 0.01 kg/m2s in a membrane-based desorber. The membrane-based architecture also enables economical small-scale systems, novel cycle configurations, and high efficiencies. The absorber, solution heat exchanger, and desorber are fabricated on a single metal sheet. In addition to the open arrangement and membrane-based architecture, another novel feature of the cycle is recovery of the solution heat energy exiting the desorber by process water (a process-solution heat exchanger ) rather than the absorber exiting solution (the conventional solution heat exchanger ). This approach has enabled heating the process water from an inlet temperature of 15 C to 57 C (conforming to the DOE water heater test standard) and interfacing the process water with absorbent on the opposite side of a single metal sheet encompassing the absorber, process-solution heat exchanger, and desorber. The system under development has a 3.2 kW water heating capacity and a target thermal coefficient of performance (COP) of 1.6.

CHUGH, Devesh [University of Florida, Gainesville; Gluesenkamp, Kyle R [ORNL; Abdelaziz, Omar [ORNL; Moghaddam, Saeed [University of Florida, Gainesville

2014-01-01T23:59:59.000Z

408

The Role of Gamma-ray Imaging in Performing Radiological Characterisation at the Magnox Storage Ponds at the Bradwell Decommissioning Site - 13628  

SciTech Connect (OSTI)

A gamma-ray imaging device has been used to perform radiological characterisation work at the spent fuel ponds complex at the site of the Bradwell Magnox Power Station, which is currently undergoing accelerated decommissioning. The objective of using a gamma-ray imaging system was to independently verify previous radiological survey work and to evaluate the adequacy of the random distribution of the destructive core sampling which had been performed. In performing this work the gamma-ray imager clearly identified the exact locations of the sources of radiation that gave rise to the elevated gamma dose rates measured by conventional health physics surveys of the area. In addition, the gamma-ray imager was able to characterise each hotspot as being either dominated by Cs-137 or by Co-60. The gamma imaging survey was undertaken with a RadScan gamma imaging system deployed on the walkways which run along the lengths of the ponds; this enabled the whole imaging survey to be performed with minimal dose uptake, demonstrating the ALARP principle within decommissioning. (authors)

Hughes, Karl; Shaw, Tracey [Babcock International, B14.1, Sellafield, Cumbria, CA20 1PG (United Kingdom)] [Babcock International, B14.1, Sellafield, Cumbria, CA20 1PG (United Kingdom)

2013-07-01T23:59:59.000Z

409

Electrical transmission line diametrical retainer  

DOE Patents [OSTI]

The invention is a mechanism for retaining an electrical transmission line. In one embodiment of the invention it is a system for retaining an electrical transmission line within down hole components. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string. The system also includes a coaxial cable running between the first and second end of a drill pipe, the coaxial cable having a conductive tube and a conductive core within it. The invention allows the electrical transmission line to with stand the tension and compression of drill pipe during routine drilling cycles.

Hall, David R. (Provo, UT); Hall, Jr., H. Tracy (Provo, UT); Pixton, David (Lehi, UT); Dahlgren, Scott (Provo, UT); Sneddon, Cameron (Provo, UT); Briscoe, Michael (Lehi, UT); Fox, Joe (Spanish Fork, UT)

2004-12-14T23:59:59.000Z

410

Pulse shaping with transmission lines  

DOE Patents [OSTI]

A method and apparatus for forming shaped voltage pulses uses passive reflection from a transmission line with nonuniform impedance. The impedance of the reflecting line varies with length in accordance with the desired pulse shape. A high voltage input pulse is transmitted to the reflecting line. A reflected pulse is produced having the desired shape and is transmitted by pulse removal means to a load. Light activated photoconductive switches made of silicon can be utilized. The pulse shaper can be used to drive a Pockels cell to produce shaped optical pulses.

Wilcox, Russell B. (Oakland, CA)

1987-01-01T23:59:59.000Z

411

Pulse shaping with transmission lines  

DOE Patents [OSTI]

A method and apparatus for forming shaped voltage pulses uses passive reflection from a transmission line with nonuniform impedance. The impedance of the reflecting line varies with length in accordance with the desired pulse shape. A high voltage input pulse is transmitted to the reflecting line. A reflected pulse is produced having the desired shape and is transmitted by pulse removal means to a load. Light activated photoconductive switches made of silicon can be utilized. The pulse shaper can be used to drive a Pockels cell to produce shaped optical pulses.

Wilcox, R.B.

1985-08-15T23:59:59.000Z

412

PAR Pond N Roads  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the1 - September 2006 The 2002Optics GroupPlanningP-GlycoproteinAmmonia R ¯bONTRACTPAR

413

Moving zone Marangoni drying of wet objects using naturally evaporated solvent vapor  

DOE Patents [OSTI]

A surface tension gradient driven flow (a Marangoni flow) is used to remove the thin film of water remaining on the surface of an object following rinsing. The process passively introduces by natural evaporation and diffusion of minute amounts of alcohol (or other suitable material) vapor in the immediate vicinity of a continuously refreshed meniscus of deionized water or another aqueous-based, nonsurfactant rinsing agent. Used in conjunction with cleaning, developing or wet etching application, rinsing coupled with Marangoni drying provides a single-step process for 1) cleaning, developing or etching, 2) rinsing, and 3) drying objects such as flat substrates or coatings on flat substrates without necessarily using heat, forced air flow, contact wiping, centrifugation or large amounts of flammable solvents. This process is useful in one-step cleaning and drying of large flat optical substrates, one-step developing/rinsing and drying or etching/rinsing/drying of large flat patterned substrates and flat panel displays during lithographic processing, and room-temperature rinsing/drying of other large parts, sheets or continuous rolls of material.

Britten, Jerald A. (Oakley, CA)

1997-01-01T23:59:59.000Z

414

Moving zone Marangoni drying of wet objects using naturally evaporated solvent vapor  

DOE Patents [OSTI]

A surface tension gradient driven flow (a Marangoni flow) is used to remove the thin film of water remaining on the surface of an object following rinsing. The process passively introduces by natural evaporation and diffusion of minute amounts of alcohol (or other suitable material) vapor in the immediate vicinity of a continuously refreshed meniscus of deionized water or another aqueous-based, nonsurfactant rinsing agent. Used in conjunction with cleaning, developing or wet etching application, rinsing coupled with Marangoni drying provides a single-step process for (1) cleaning, developing or etching, (2) rinsing, and (3) drying objects such as flat substrates or coatings on flat substrates without necessarily using heat, forced air flow, contact wiping, centrifugation or large amounts of flammable solvents. This process is useful in one-step cleaning and drying of large flat optical substrates, one-step developing/rinsing and drying or etching/rinsing/drying of large flat patterned substrates and flat panel displays during lithographic processing, and room-temperature rinsing/drying of other large parts, sheets or continuous rolls of material. 5 figs.

Britten, J.A.

1997-08-26T23:59:59.000Z

415

Slow positron annihilation spectroscopy and electron microscopy of electron beam evaporated cobalt and nickel silicides  

SciTech Connect (OSTI)

Metal silicide thin films on single-crystal silicon substrates are the subject of much research, due to their applications as electrical contacts and interconnects, diffusion barriers, low resistance gates, and field-assisted positron moderators, among others. Defects within the silicide layer and/or at the silicide/silicon interface are detrimental to device performance, since they can act as traps for charge carriers, as well as positrons. Pinholes penetrating the film are another detriment particularly for cobalt silicide films, since they allow electrons to permeate the film, rather than travel ballistically, in addition to greatly increasing surface area for recombination events. A series of epitaxial cobalt and nickel silicide thin films, deposited via electron-beam evaporation and annealed at various temperatures, have been grown on single-crystal silicon (111) substrates, in an effort to establish a relationship between deposition and processing parameters and film quality. The films have been analyzed by transmission and scanning electron microscopy, sputter depth profile Auger, and slow positron annihilation spectroscopy. The latter has been shown to both correlate and complement the traditional electron microscopy results.

Frost, R.L.; DeWald, A.B. (Georgia Institute of Technology, Atlanta, Georgia 30332 (USA)); Zaluzec, M.; Rigsbee, J.M. (University of Illinois, Urbana, Illinois 61801 (USA)); Nielsen, B.; Lynn, K.G. (Brookhaven National Laboratory, Upton, New York 11973 (USA))

1990-07-01T23:59:59.000Z

416

Oxidation behavior of arc evaporated Al-Cr-Si-N thin films  

SciTech Connect (OSTI)

The impact of Al and Si on the oxidation behavior of Al-Cr-(Si)-N thin films synthesized by arc evaporation of powder metallurgically prepared Al{sub x}Cr{sub 1-x} targets with x = Al/(Al + Cr) of 0.5, 0.6, and 0.7 and (Al{sub 0.5}Cr{sub 0.5}){sub 1-z}Si{sub z} targets with Si contents of z = 0.05, 0.1, and 0.2 in N{sub 2} atmosphere was studied in detail by means of differential scanning calorimetry, thermogravimetric analysis (TGA), x-ray diffraction, and Raman spectroscopy. Dynamical measurements in synthetic air (up to 1440 Degree-Sign C) revealed the highest onset temperature of pronounced oxidation for nitride coatings prepared from the Al{sub 0.4}Cr{sub 0.4}Si{sub 0.2} target. Isothermal TGA at 1100, 1200, 1250, and 1300 Degree-Sign C highlight the pronounced improvement of the oxidation resistance of Al{sub x}Cr{sub 1-x}N coatings by the addition of Si. The results show that Si promotes the formation of a dense coating morphology as well as a dense oxide scale when exposed to air.

Tritremmel, Christian; Daniel, Rostislav; Mitterer, Christian; Mayrhofer, Paul H.; Lechthaler, Markus; Polcik, Peter [Christian Doppler Laboratory for Advanced Hard Coatings, Department of Physical Metallurgy and Materials Testing, Montanuniversitaet Leoben, Franz-Josef-Strasse 18, A-8700 Leoben (Austria); Christian Doppler Laboratory for Application Oriented Coating Development, Department of Physical Metallurgy and Materials Testing, Montanuniversitaet Leoben, Franz-Josef-Strasse 18, A-8700 Leoben (Austria); OC Oerlikon Balzers AG, Iramali 18, LI-9496 Balzers (Liechtenstein); PLANSEE Composite Materials GmbH, Siebenbuergerstrasse 23, D-86983 Lechbruck am See (Germany)

2012-11-15T23:59:59.000Z

417

Surface chemistry of stainless steel and evaporated titanium layers in tokamaks  

SciTech Connect (OSTI)

The combined use of x-ray photoelectron spectroscopy and secondary ion mass spectroscopy is shown to be a powerful tool in the investigation of the chemical modifications of a surface in interaction with a plasma. The reported investigations are performed in-situ in the surface analysis station of the PDX tokamak. The evolution of stainless steel surfaces is followed after various treatments such as hydrogen glow discharge conditioning (GDC), exposure to tokamak discharges, and ion sputtering. Iron oxides are shown to be partially reduced by exposure to GDC; the metal-oxide binding is converted to metal-hydroxide binding from which water can be desorbed. The oxygen behavior on evaporated titanium films is substantially different: the oxide layer evolves to higher oxidation states during exposure to GDC. In contrast, the behavior of carbon is identical on both stainless steel and titanium surfaces: carbon is removed during exposure to GDC via the formation of methane which can spontaneously desorb from the surface.

Staib, P.; Dylla, H.F.; Rossenagel, S.M.

1980-08-01T23:59:59.000Z

418

Milagro Limits and HAWC Sensitivity for the Rate-Density of Evaporating Primordial Black Holes  

E-Print Network [OSTI]

Primordial Black Holes (PBHs) are gravitationally collapsed objects that may have been created by density fluctuations in the early universe and could have arbitrarily small masses down to the Planck scale. Hawking showed that due to quantum effects, a black hole has a temperature inversely proportional to its mass and can emit all species of fundamental particles thermally. PBHs with initial masses of ~5.0 x 10^14 g should be expiring in the present epoch with bursts of high-energy particles, including gamma radiation in the GeV - TeV energy range, making them candidate Gamma-ray Burst (GRB) progenitors. The Milagro high energy observatory, which operated from 2000 to 2008, is sensitive to the high end of the PBH evaporation gamma-ray spectrum. Due to its large field-of-view, more than 90% duty cycle and sensitivity up to 100 TeV gamma-rays, the Milagro observatory is well suited for a direct search of PBH bursts. Based on a search on the Milagro data, we report new PBH burst rate density upper limits over a...

Abdo, A A; Alfaro, R; Allen, B T; Alvarez, C; lvarez, J D; Arceo, R; Arteaga-Velzquez, J C; Aune, T; Solares, H A Ayala; Barber, A S; Baughman, B M; Bautista-Elivar, N; Gonzalez, J Becerra; Belmont, E; BenZvi, S Y; Berley, D; Rosales, M Bonilla; Braun, J; Caballero-Lopez, R A; Caballero-Mora, K S; Carramiana, A; Castillo, M; Chen, C; Christopher, G E; Cotti, U; Cotzomi, J; de la Fuente, E; De Len, C; DeYoung, T; Hernandez, R Diaz; Diaz-Cruz, L; Daz-Vlez, J C; Dingus, B L; DuVernois, M A; Ellsworth, R W; Fiorino, D W; Fraija, N; Galindo, A; Garfias, F; Gonzlez, M M; Goodman, J A; Grabski, V; Gussert, M; Hampel-Arias, Z; Harding, J P; Hays, E; Hoffman, C M; Hui, C M; Hntemeyer, P; Imran, A; Iriarte, A; Karn, P; Kieda, D; Kolterman, B E; Kunde, G J; Lara, A; Lauer, R J; Lee, W H; Lennarz, D; Vargas, H Len; Linares, E C; Linnemann, J T; Longo, M; Luna-GarcIa, R; MacGibbon, J H; Marinelli, A; Marinelli, S S; Martinez, H; Martinez, O; Martnez-Castro, J; Matthews, J A J; McEnery, J; Torres, E Mendoza; Mincer, A I; Miranda-Romagnoli, P; Moreno, E; Morgan, T; Mostaf, M; Nellen, L; Nemethy, P; Newbold, M; Noriega-Papaqui, R; Oceguera-Becerra, T; Patricelli, B; Pelayo, R; Prez-Prez, E G; Pretz, J; Rivire, C; Rosa-Gonzlez, D; Ruiz-Velasco, E; Ryan, J; Salazar, H; Salesa, F; Sandoval, A; Parkinson, P M Saz; Schneider, M; Shoup, A; Silich, S; Sinnis, G; Smith, A J; Stump, D; Woodle, K Sparks; Springer, R W; Taboada, I; Toale, P A; Tollefson, K; Torres, I; Ukwatta, T N; Vasileiou, V; Villaseor, L; Walker, G P; Weisgarber, T; Westerhoff, S; Williams, D A; Wisher, I G; Wood, J; Yodh, G B; Younk, P W; Zaborov, D; Zepeda, A; Zhou, H

2014-01-01T23:59:59.000Z

419

ANALYSES AND COMPARISON OF BULK AND COIL SURFACE SAMPLES FROM THE DWPF SLURRY MIX EVAPORATOR  

SciTech Connect (OSTI)

Sludge samples from the DWPF Slurry Mix Evaporator (SME) heating coil frame and coil surface were characterized to identify differences that might help identify heat transfer fouling materials. The SME steam coils have seen increased fouling leading to lower boil-up rates. Samples of the sludge were taken from the coil frame somewhat distant from the coil (bulk tank material) and from the coil surface (coil surface sample). The results of the analysis indicate the composition of the two SME samples are very similar with the exception that the coil surface sample shows {approx}5-10X higher mercury concentration than the bulk tank sample. Elemental analyses and x-ray diffraction results did not indicate notable differences between the two samples. The ICP-MS and Cs-137 data indicate no significant differences in the radionuclide composition of the two SME samples. Semi-volatile organic analysis revealed numerous organic molecules, these likely result from antifoaming additives. The compositions of the two SME samples also match well with the analyzed composition of the SME batch with the exception of significantly higher silicon, lithium, and boron content in the batch sample indicating the coil samples are deficient in frit relative to the SME batch composition.

Hay, M.; Nash, C.; Stone, M.

2012-02-17T23:59:59.000Z

420

Heat capacity measurements of atoms and molecules adsorbed on evaporated metal films  

SciTech Connect (OSTI)

Investigations of the properties of absorbed monolayers have received great experimental and theoretical attention recently, both because of the importance of surface processes in practical applications such as catalysis, and the importance of such systems to the understanding of the fundamentals of thermodynamics in two dimensions. We have adapted the composite bolometer technology to the construction of microcalorimeters. For these calorimeters, the adsorption substrate is an evaporated film deposited on one surface of an optically polished sapphire wafer. This approach has allowed us to make the first measurements of the heat capacity of submonolayer films of /sup 4/He adsorbed on metallic films. In contrast to measurements of /sup 4/He adsorbed on all other insulating substrates, we have shown that /sup 4/He on silver films occupies a two-dimensional gas phase over a broad range of coverages and temperatures. Our apparatus has been used to study the heat capacity of Indium flakes. CO multilayers, /sup 4/He adsorbed on sapphire and on Ag films and H/sub 2/ adsorbed on Ag films. The results are compared with appropriate theories. 68 refs., 19 figs.

Kenny, T.W.

1989-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "lined evaporation pond" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Use of non evaporable getter pumps to ensure long term performances of high quantum efficiency photocathodes  

SciTech Connect (OSTI)

High quantum efficiency photocathodes are routinely used as laser triggered emitters in the advanced high brightness electron sources based on radio frequency guns. The sensitivity of semiconductor type photocathodes to vacuum levels and gas composition requires special care during preparation and handling. This paper will discuss the results obtained using a novel pumping approach based on coupling a 20?l s{sup ?1} sputter ion getter pump with a CapaciTorr D100 non evaporable getter (NEG) pump. A pressure of 8?10{sup ?8}?Pa was achieved using only a sputter ion pump after a 6?day bake-out. With the addition of a NEG pump, a pressure of 2?10{sup ?9}?Pa was achieved after a 2?day bake-out. These pressure values were maintained without power due to the ability of the NEG to pump gases by chemical reaction. Long term monitoring of cathodes quantum efficiencies was also carried out at different photon wavelengths for more than two years, showing no degradation of the photoemissive film properties.

Sertore, Daniele, E-mail: daniele.sertore@mi.infn.it; Michelato, Paolo; Monaco, Laura [Istituto Nazionale di Fisica Nucleare Sez. Milano LASA, Via Fratelli Cervi 201, I-20090 Segrate (Italy); Manini, Paolo; Siviero, Fabrizio [SAES Getters S.p.A., Viale Italia 77, 20020 Lainate (Italy)

2014-05-15T23:59:59.000Z

422

Annealing effect for SnS thin films prepared by high-vacuum evaporation  

SciTech Connect (OSTI)

Thin films of SnS are deposited onto molybdenum-coated soda lime glass substrates using the high-vacuum evaporation technique at a substrate temperature of 300?C. The as-deposited SnS layers are then annealed in three different media: (1) H{sub 2}S, (2) argon, and (3) vacuum, for different periods and temperatures to study the changes in the microstructural properties of the layers and to prepare single-phase SnS photoabsorber films. It is found that annealing the layers in H{sub 2}S at 400?C changes the stoichiometry of the as-deposited SnS films and leads to the formation of a dominant SnS{sub 2} phase. Annealing in an argon atmosphere for 1?h, however, causes no deviations in the composition of the SnS films, though the surface morphology of the annealed SnS layers changes significantly as a result of a 2?h annealing process. The crystalline structure, surface morphology, and photosensitivity of the as-deposited SnS films improves significantly as the result of annealing in vacuum, and the vacuum-annealed films are found to exhibit promising properties for fabricating complete solar cells based on these single-phase SnS photoabsorber layers.

Revathi, Naidu, E-mail: revathi.naidu@ttu.ee; Bereznev, Sergei; Loorits, Mihkel; Raudoja, Jaan; Lehner, Julia; Gurevits, Jelena; Traksmaa, Rainer; Mikli, Valdek; Mellikov, Enn; Volobujeva, Olga [Department of Materials Science, Tallinn University of Technology, Ehitajate tee 5, Tallinn 19086 (Estonia)

2014-11-01T23:59:59.000Z

423

Authorization of Line Extension (Nebraska)  

Broader source: Energy.gov [DOE]

Any entity permitted to establish an electric light and power plant, and/or transmission or distribution lines within a city, village, or public electric light and power district, may also extend...

424

Transmission Lines Emulating Moving Media  

E-Print Network [OSTI]

In this paper, we show how the electromagnetic phenomena in moving magnetodielectric media can be emulated using artificial composite structures at rest. In particular, we introduce nonreciprocal periodically loaded transmission lines which support waves obeying the same rules as plane electromagnetic waves in moving media. Because the actual physical structure is at rest, in these transmission lines there are no fundamental limitations on the velocity values, which may take values larger than the speed of light or even complex values (considering complex amplitudes in the time-harmonic regime). An example circuit of a unit cell of a "moving" transmission line is presented and analyzed both numerically and experimentally. The special case of composite right/left handed host line is also studied numerically. Besides the fundamental interest, the study is relevant for potential applications in realizing engineered materials for various transformations of electromagnetic fields.

Vehmas, Joni; Tretyakov, Sergei

2014-01-01T23:59:59.000Z

425

Analysis of interconnect microstrip lines  

E-Print Network [OSTI]

of the return loss of the slot-coupled microstrip dipole. Section C presents two simulations of the return loss on the slot- coupled rectangular patch antenna. A. Interconnect of Microstrip Lines Several circuits with the geometry of Figure 1 were fabricated.... Experimental and Theoretical Results of the Interconnect Two circuits were designed and fabricated. Each circuit consists of two substrates as shown in Figure 9. One substrate has an open microstrip line etched in one side and an aperture etched...

Luong, Giam-Minh

1992-01-01T23:59:59.000Z

426

Fin-line horn antenna  

DOE Patents [OSTI]

A fin line circuit card containing a fin line slot feeds a dipole antenna ich extends a quarterwave outside the waveguide and provides an energy beam focal point at or near the open end of the waveguide. The dipole antenna thus maintains a wide and nearly constant beamwidth, low VSWR and a circular symmetric radiation pattern for use in electronic warfare direction finding and surveillance applications.

Reindel, John (San Diego, CA)

1990-01-01T23:59:59.000Z

427

HAZWOPER project documents for demolition of the Waste Evaporator Facility, Building 3506, at Oak Ridge National Laboratory, Oak Ridge, Tennessee  

SciTech Connect (OSTI)

This document, in support of the Waste Evaporator Facility (WEF) demolition project and contains the Project Work Plan and the Project Health and Safety Plan for demolition and partial remediation actions by ATG at the Waste Evaporator Facility, Building 3506. Various activities will be conducted during the course of demolition, and this plan provides details on the work steps involved, the identification of hazards, and the health and safety practices necessary to mitigate these hazards. The objective of this document is to develop an approach for implementing demolition activities at the WEF. This approach is based on prior site characterization information and takes into account all of the known hazards at this facility. The Project Work Plan provides instructions and requirements for identified work steps that will be utilized during the performance of demolition, while the Health and Safety Plan addresses the radiological, hazardous material exposure, and industrial safety concerns that will be encountered.

NONE

1996-03-01T23:59:59.000Z

428

Design, fabrication and testing of a 15-kW gas-fired liquid-metal evaporator  

SciTech Connect (OSTI)

This paper describes the development and testing of a compact heat- pipe heat exchanger that is designed to transfer thermal energy from hot combustion gases to the heater tubes of a 25-kW{sub e} Stirling engine. In this system, sodium evaporates from a surface that is heated by a stream of hot gases and the liquid metal then condenses on the heater tubes of a Stirling engine where energy is transferred to the engine's helium working fluid. Recent tests on a prototype unit illustrated that a compact (8 cm {times} 13 cm {times} 16 cm) sodium evaporator can routinely transfer 15-kW{sub t} of energy at an operating vapor temperature of 760{degrees}C. Four of these prototype units will eventually be used to power a 25-kW{sub e} Stirling engine system. Design details and test results from the prototype unit are presented in this paper.

Adkins, D.R.; Rawlinson, K.S.

1992-01-01T23:59:59.000Z

429

Design, fabrication and testing of a 15-kW gas-fired liquid-metal evaporator  

SciTech Connect (OSTI)

This paper describes the development and testing of a compact heat- pipe heat exchanger that is designed to transfer thermal energy from hot combustion gases to the heater tubes of a 25-kW{sub e} Stirling engine. In this system, sodium evaporates from a surface that is heated by a stream of hot gases and the liquid metal then condenses on the heater tubes of a Stirling engine where energy is transferred to the engine`s helium working fluid. Recent tests on a prototype unit illustrated that a compact (8 cm {times} 13 cm {times} 16 cm) sodium evaporator can routinely transfer 15-kW{sub t} of energy at an operating vapor temperature of 760{degrees}C. Four of these prototype units will eventually be used to power a 25-kW{sub e} Stirling engine system. Design details and test results from the prototype unit are presented in this paper.

Adkins, D.R.; Rawlinson, K.S.

1992-07-01T23:59:59.000Z

430

Design, fabrication, and testing of a sodium evaporator for the STM4-120 kinematic Stirling engine  

SciTech Connect (OSTI)

This report describes the development and testing of a compact heat-pipe heat exchanger kW(e) designed to transfer thermal energy from hot combustion gases to the heater tubes of a 25-kW(e) Stirling engine. In this system, sodium evaporates from a surface that is heated by a stream of hot gases. The liquid metal then condenses on the heater tubes of a Stirling engine, where energy is transferred to the engine`s helium working fluid. Tests on a prototype unit illustrated that a compact (8 cm {times} 13 cm {times} 16 cm) sodium evaporator can routinely transfer 15 kW(t) of energy at an operating vapor temperature of 760 C. Four of these prototype units were eventually used to power a 25-kW(e) Stirling engine system. Design details and test results from the prototype unit are presented in this report.

Rawlinson, K.S.; Adkins, D.R.

1995-05-01T23:59:59.000Z

431

Effects of system cycling, evaporator airflow, and condenser coil fouling on the performance of residential split-system air conditioners  

E-Print Network [OSTI]

EFFECTS OF SYSTEM CYCLING, EVAPORATOR AIRFLOW, AND CONDENSER COIL FOULING ON THE PERFORMANCE OF RESIDENTIAL SPLIT-SYSTEM AIR CONDITIONERS A Thesis by JEFFREY BRANDON DOOLEY Submitted to the Office of Graduate Studies... COIL FOULING ON THE PERFORMANCE OF RESIDENTIAL SPLIT-SYSTEM AIR CONDITIONERS A Thesis by JEFFREY BRANDON DOOLEY Submitted to Texas A&M University in partial fulfillment of the requirements for the degree of MASTER...

Dooley, Jeffrey Brandon

2005-02-17T23:59:59.000Z

432

Evaporation heat transfer and friction characteristics of R-134a flowing downward in a vertical corrugated tube  

SciTech Connect (OSTI)

Differently from most previous studies, the heat transfer and friction characteristics of the pure refrigerant HFC-134a during evaporation inside a vertical corrugated tube are experimentally investigated. The double tube test sections are 0.5 m long with refrigerant flowing in the inner tube and heating water flowing in the annulus. The inner tubes are one smooth tube and two corrugated tubes, which are constructed from smooth copper tube of 8.7 mm inner diameter. The test runs are performed at evaporating temperatures of 10, 15, and 20 C, heat fluxes of 20, 25, and 30 kW/m{sup 2}, and mass fluxes of 200, 300, and 400 kg/m{sup 2} s. The quality of the refrigerant in the test section is calculated using the temperature and pressure obtained from the experiment. The pressure drop across the test section is measured directly by a differential pressure transducer. The effects of heat flux, mass flux, and evaporation temperature on the heat transfer coefficient and two-phase friction factor are also discussed. It is found that the percentage increases of the heat transfer coefficient and the two-phase friction factor of the corrugated tubes compared with those of the smooth tube are approximately 0-10% and 70-140%, respectively. (author)

Aroonrat, Kanit; Wongwises, Somchai [Fluid Mechanics, Thermal Engineering and Multiphase Flow Research Lab. (FUTURE), Department of Mechanical Engineering, King Mongkut's University of Technology Thonburi, Bangmod, Bangkok 10140 (Thailand)

2011-01-15T23:59:59.000Z

433

Florida Electric Transmission Line Siting Act (Florida)  

Broader source: Energy.gov [DOE]

The Transmission Line Siting Act (TLSA) is the states centralized process for licensing electrical transmission lines which; (a) are 230 kV or larger; (b) cross a county line; and, (c) are 15...

434

For the designers, nature is the nucleus represented by the pond, moving gradually away from nature leads though a large open space towards the solar field, representing man-made technology.  

E-Print Network [OSTI]

from nature leads though a large open space towards the solar field, representing man-made technology to technology. In our design, the pond is a representation of nature, while the solar field on the extreme side is a representation of the man-made technology. We provide a connection between these two opposite concepts and offer

Goodman, Robert M.

435

Radiological Monitoring Results For Groundwater Samples Associated with the Industrial Wastewater Reuse Permit for the Materials and Fuels Complex Industrial Waste Ditch and Pond: November 1, 2010-October 31, 2011  

SciTech Connect (OSTI)

This report summarizes radiological monitoring performed on samples from specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit for the Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond (No.LA-000160-01). The radiological monitoring was performed to fulfill Department of Energy requirements under the Atomic Energy Act.

David Frederick

2012-02-01T23:59:59.000Z

436

Radiological Monitoring Results for Groundwater Samples Associated with the Industrial Wastewater Reuse Permit for the Materials and Fuels Complex Industrial Waste Ditch and Pond: November 1, 2012-October 31, 2013  

SciTech Connect (OSTI)

This report summarizes radiological monitoring performed on samples from specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit for the Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond WRU-I-0160-01, Modification 1 (formerly LA-000160-01). The radiological monitoring was performed to fulfill Department of Energy requirements under the Atomic Energy Act.

Mike Lewis

2014-02-01T23:59:59.000Z

437

Radiological Monitoring Results For Groundwater Samples Associated with the Industrial Wastewater Reuse Permit for the Materials and Fuels Complex Industrial Waste Ditch and Pond: May 1, 2010-October 31, 2010  

SciTech Connect (OSTI)

This report summarizes radiological monitoring performed on samples from specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit for the Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond (#LA-000160-01). The radiological monitoring was performed to fulfill Department of Energy requirements under the Atomic Energy Act.

David B. Frederick

2011-02-01T23:59:59.000Z

438

Radiological Monitoring Results for Groundwater Samples Associated with the Industrial Wastewater Reuse Permit for the Materials and Fuels Complex Industrial Waste Ditch and Pond: November 1, 2011-October 31, 2012  

SciTech Connect (OSTI)

This report summarizes radiological monitoring performed on samples from specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit for the Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond WRU-I-0160-01, Modification 1 (formerly LA-000160-01). The radiological monitoring was performed to fulfill Department of Energy requirements under the Atomic Energy Act.

Mike lewis

2013-02-01T23:59:59.000Z

439

Spray evaporation heat transfer performance in R-123 in tube bundles  

SciTech Connect (OSTI)

This study focuses on evaluating the heat transfer performance of refrigerant R-123 in the spray evaporation environment for pure refrigerant and for the case of lubricant addition. Tests were conducted with triangular-pitch tube bundles made from enhanced boiling tubes, enhanced condensation tubes, and plain-surface tubes. A second enhanced boiling surface tube bundle, made with a square-pitch tube alignment, was also tested so a comparison could be made between the square- and triangular-pitch geometries. In addition to pure refrigerant work, experiments were performed with small concentrations of a 305 SUS naphthenic mineral oil to evaluate its effect on falling-film heat transfer performance. Two different refrigerant supply rates were used in this work so the effects of film-feed supply rate could be interpreted from the data. Refrigerant was introduced to the test section via low-pressure-drop, wide-angle nozzles located directly over the tube bundle. Data were taken over a heat flux range of 40 kW/m{sup 2} (12,688 Btu/[h{center_dot}ft{sup 2}]) to 19 kW/m{sup 2} (6,027 Btu/[h{center_dot}ft{sup 2}]), while the refrigerant supply rate remained fixed. Collector tests were performed in parallel with the heat transfer experiments so the amount of refrigerant bypassing the tube bundle could be determined. It was found that the heat transfer coefficients were dependent upon film-feed supply rate, oil concentration, and heat flux. The enhanced boiling surface yielded higher heat transfer coefficients than either the enhanced condensation surface or the plain surface.

Moeykens, S. [Trane Co., LaCrosse, WI (United States); Kelly, J.E. [Kansas State Univ., Manhattan, KS (United States). Dept. of Mechanical Engineering; Pate, M.B. [Iowa State Univ., Ames, IA (United States). Mechanical Engineering Dept.

1996-12-31T23:59:59.000Z

440

What can emission lines tell us?  

E-Print Network [OSTI]

1 Generalities 2 Empirical diagnostics based on emission lines 3 Photoionization modelling 4 Pending questions 5 Appendix: Lists of useful lines and how to deal with them

G. Stasinska

2007-04-03T23:59:59.000Z

Note: This page contains sample records for the topic "lined evaporation pond" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Objective determination of optimal power line designs.  

E-Print Network [OSTI]

??Includes abstract. The thesis investigated the possibility of overhead power line designs being decided by using an objective rather thana subjective method. Power lines are (more)

Stephen, Robert G.

2010-01-01T23:59:59.000Z

442

COARSE-GRAINED REFRACTORY INCLUSIONS: CONDENSATES, EVAPORATION RESIDUES, OR BOTH? EVIDENCE FROM MAJOR ELEMENT BULK COMPOSITIONS. S. B. Simon, D. S. Ebel, L. Grossman1  

E-Print Network [OSTI]

COARSE-GRAINED REFRACTORY INCLUSIONS: CONDENSATES, EVAPORATION RESIDUES, OR BOTH? EVIDENCE FROM from bulk equilibrium condensates calculated for a gas of solar composition. Literature data for major expected from equilibrium condensation. We also performed thermodynamic calculations to evaluate the degree

Grossman, Lawrence

443

Quasistellar Objects: Intervening Absorption Lines  

E-Print Network [OSTI]

We briefly review, at a level appropriate for graduate students and non-specialists, the field of quasar absorption lines (QALs). Emphasis is on the intervening absorbers. We present the anatomy of a quasar spectrum due to various classes of intervening absorption systems, and a brief historical review of each absorber class (Lyman-alpha forest and Lyman limit systems, and metal-line and damped Lyman-alpha absorbers). We also provide several heuristic examples on how the physical properties of both the intergalactic medium and the gaseous environments associated with earlier epoch galaxies can be inferred from QALs. The evolution of these environments from z=4 are discussed.

Jane C. Charlton; Christopher W. Churchill

2000-05-31T23:59:59.000Z

444

POST CLOSURE INSPECTION REPORT FOR CORRECTIVE ACTION UNIT 92: AREA 6 DECON POND FACILITY, NEVADA TEST SITE, NEVADA; FOR CALENDAR YEAR 2005  

SciTech Connect (OSTI)

This Post-Closure Inspection Report provides an analysis and summary of inspections for Corrective Action Unit (CAU) 92, Area 6 Decon Pond Facility, Nevada Test Site, Nevada. CAU 92 was closed in accordance with the Resource Conservation and Recovery Act (RCRA) Part B Operational Permit (Nevada Division of Environmental Protection (NDEP), 1995) and the Federal Facility Agreement and Consent Order of 1996. Closure activities were completed on February 16, 1999, and the Closure Report (U.S. Department of Energy, Nevada Operations Office, 1999) was approved and a Notice of Completion issued by the NDEP on May 11, 1999. CAU 92 consists of two Corrective Action Sites (CASs): CAS 06-04-01, Decon Pad Oil/Water Separator; and CAS 06-05-02, Decontamination Pond (RCRA). Both CASs have use restrictions; however, only CAS 06-05-02 requires post-closure inspections. Visual inspections of the cover and fencing at CAS 06-05-02 are performed quarterly. Additional inspections are conducted if precipitation occurs in excess of 1.28 centimeters (cm) (0.50 inches [in]) in a 24-hour period. This report covers calendar year 2005. Quarterly site inspections were performed in March, June, September, and December of 2005. All observations indicated the continued integrity of the unit. No issues or concerns were noted, and no corrective actions were necessary. Copies of the inspection checklists and field notes completed during each inspection are included in Appendix A. Five additional inspections were performed after precipitation events that exceeded 1.28 cm (0.50 in) within a 24-hour period during 2005. No significant changes in site conditions were noted during these inspections, and no corrective actions were necessary. Copies of the inspection checklists and field notes completed during each inspection are included in Appendix A. Precipitation records for 2005 are included in Appendix C.

NA

2006-03-01T23:59:59.000Z

445

PILOT-SCALE TEST RESULTS OF A THIN FILM EVAPORATOR SYSTEM FOR MANAGEMENT OF LIQUID HIGH-LEVEL WASTES AT THE HANFORD SITE WASHINGTON USA -11364  

SciTech Connect (OSTI)

A modular, transportable evaporator system, using thin film evaporative technology, is planned for deployment at the Hanford radioactive waste storage tank complex. This technology, herein referred to as a wiped film evaporator (WFE), will be located at grade level above an underground storage tank to receive pumped liquids, concentrate the liquid stream from 1.1 specific gravity to approximately 1.4 and then return the concentrated solution back into the tank. Water is removed by evaporation at an internal heated drum surface exposed to high vacuum. The condensed water stream will be shipped to the site effluent treatment facility for final disposal. This operation provides significant risk mitigation to failure of the aging 242-A Evaporator facility; the only operating evaporative system at Hanford maximizing waste storage. This technology is being implemented through a development and deployment project by the tank farm operating contractor, Washington River Protection Solutions (WRPS), for the Office of River Protection/Department of Energy (ORPIDOE), through Columbia Energy and Environmental Services, Inc. (Columbia Energy). The project will finalize technology maturity and install a system at one of the double-shell tank farms. This paper summarizes results of a pilot-scale test program conducted during calendar year 2010 as part of the ongoing technology maturation development scope for the WFE.

CORBETT JE; TEDESCH AR; WILSON RA; BECK TH; LARKIN J

2011-02-14T23:59:59.000Z

446

Coiled transmission line pulse generators  

DOE Patents [OSTI]

Methods and apparatus are provided for fabricating and constructing solid dielectric "Coiled Transmission Line" pulse generators in radial or axial coiled geometries. The pour and cure fabrication process enables a wide variety of geometries and form factors. The volume between the conductors is filled with liquid blends of monomers, polymers, oligomers, and/or cross-linkers and dielectric powders; and then cured to form high field strength and high dielectric constant solid dielectric transmission lines that intrinsically produce ideal rectangular high voltage pulses when charged and switched into matched impedance loads. Voltage levels may be increased by Marx and/or Blumlein principles incorporating spark gap or, preferentially, solid state switches (such as optically triggered thyristors) which produce reliable, high repetition rate operation. Moreover, these Marxed pulse generators can be DC charged and do not require additional pulse forming circuitry, pulse forming lines, transformers, or an a high voltage spark gap output switch. The apparatus accommodates a wide range of voltages, impedances, pulse durations, pulse repetition rates, and duty cycles. The resulting mobile or flight platform friendly cylindrical geometric configuration is much more compact, light-weight, and robust than conventional linear geometries, or pulse generators constructed from conventional components. Installing additional circuitry may accommodate optional pulse shape improvements. The Coiled Transmission Lines can also be connected in parallel to decrease the impedance, or in series to increase the pulse length.

McDonald, Kenneth Fox (Columbia, MO)

2010-11-09T23:59:59.000Z

447

Operation of automated NDA instruments for in-line HEU accounting at Y-12  

SciTech Connect (OSTI)

Two automated nondestructive assay instruments developed at Los Alamos in support of nuclear materials accounting needs are currently operating in-line at the Y-12 Plant for recovery of highly enriched uranium. One instrument provides the HEU inventory in the secondary solvent extraction system, and the other monitors HEU concentration in the secondary intermediate evaporator. Both instruments were installed in December 1982. Operational evaluation of these instruments has been a joint effort of Y-12 and Los Alamos. This has included comparison of the solvent extraction system inventories with direct measurement performed on the dumped solution components of the solvent extraction system, as well as comparisons of concentration assay results with the external assays of samples withdrawn from the process. The function, design, and preliminary results of the operational evaluation are reported.

Russo, P.A.; Strittmatter, R.B.; Sandford, E.L.; Jeter, I.W.; McCullough, E.; Bowers, G.L.

1983-01-01T23:59:59.000Z

448

Report on Produced Water  

Office of Scientific and Technical Information (OSTI)

of the pond, as well as the quality of the produced water. In semiarid regions, hot, dry air moving from a land surface will result in high evaporation rates for smaller ponds. As...

449

Measurement of the work function of filament-evaporated M?g???[?subscript -x]A?u?[?subscript x] films  

E-Print Network [OSTI]

) Roland E. Allen (Member) Mi Lu ( Member) J. W. Howze (Head of Department) December Igg0 ABSTRACT Measurement of the Work Function of Filament-Evaporated Mgr, Au Films. (December 1990) Dong Li, M. S. , Institute of Physics, Chinese Academy... energy hv I = AT'(W, ? hv) '~'f( ) hT (1. 2) where A is a constant independent of v, T and P. W, is the surface potential and and f(x) 1 )u+1 n2 u=r 2 2 cd ? uz ? + ? ? 2 (-I)"" 6 2 ?, nr (z & 0) (& -0) (1. 3) Journal model is IEEE Transactions...

Li, Dong

1990-01-01T23:59:59.000Z

450

Heating dynamics of CO{sub 2}-laser irradiated silica particles with evaporative shrinking: Measurements and modeling  

SciTech Connect (OSTI)

The heating dynamics of CO{sub 2}-laser heated micron-sized particles were determined for temperatures <3500 K measured using infrared imaging. A coupled mass and energy conservation model is derived to predict single particle temperatures and sizes, which were compared with data from particles deposited on non-absorbing substrates to assess the relevant heat transfer processes. Analysis reveals substrate conduction dominates all other heat losses, while laser absorption determined from Mie theory is strongly modulated by particle evaporative shrinking. This study provides insights into the light coupling and heating of particle arrays where the material optical properties are temperature-dependent and particle size changes are significant.

Elhadj, S.; Qiu, S. R.; Stolz, C. J. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Monterrosa, A. M. [Department of Nuclear Engineering and Department of Materials Science and Engineering, University of California, Berkeley, California 94704 (United States)

2012-05-01T23:59:59.000Z

451

The MICE Muon Beam Line  

SciTech Connect (OSTI)

In the Muon Ionization Cooling Experiment (MICE) at RAL, muons are produced and transported in a dedicated beam line connecting the production point (target) to the cooling channel. We discuss the main features of the beamline, meant to provide muons with momenta between 140 MeV/c and 240 MeV/c and emittances up to 10 mm rad, which is accomplished by means of a diffuser. Matching procedures to the MICE cooling channel are also described. In summer 2010 we performed an intense data taking campaign to finalize the calibration of the MICE Particle Identification (PID) detectors and the understanding of the beam line, which completes the STEPI phase of MICE. We highlight the main results from these data.

Apollonio, Marco [High Energy Physics Group, Department of Physics, Imperial College London SW7 2AZ (United Kingdom)

2011-10-06T23:59:59.000Z

452

In-line thermoelectric module  

DOE Patents [OSTI]

A thermoelectric module with a plurality of electricity generating units each having a first end and a second end, the units being arranged first end to second end along an in-line axis. Each unit includes first and second elements each made of a thermoelectric material, an electrically conductive hot member arranged to heat one side of the first element, and an electrically conductive cold member arranged to cool another side of the first element and to cool one side of the second element. The hot member, the first element, the cold member and the second element are supported in a fixture, are electrically connected respectively to provide an electricity generating unit, and are arranged respectively in positions along the in-line axis. The individual components of each generating unit and the respective generating units are clamped in their in-line positions by a loading bolt at one end of the fixture and a stop wall at the other end of the fixture. The hot members may have a T-shape and the cold members an hourglass shape to facilitate heat transfer. The direction of heat transfer through the hot members may be perpendicular to the direction of heat transfer through the cold members, and both of these heat transfer directions may be perpendicular to the direction of current flow through the module.

Pento, Robert (Algonquin, IL); Marks, James E. (Glenville, NY); Staffanson, Clifford D. (S. Glens Falls, NY)

2000-01-01T23:59:59.000Z

453

In-Line Thermoelectric Module  

SciTech Connect (OSTI)

A thermoelectric module with a plurality of electricity generating units each having a first end and a second end, the units being arranged first end to second end along an-in-line axis. Each unit includes first and second elements each made of a thermoelectric material, an electrically conductive hot member arranged to heat one side of the first element, and an electrically conductive cold member arranged to cool another side of the first element and to cool one side of the second element. The hot member, the first element, the cold member and the second element are supported in a fixture, are electrically connected respectively to provide an electricity generating unit, and are arranged respectively in positions along the in-line axis. The individual components of each generating unit and the respective generating units are clamped in their in-line positions by a loading bolt at one end of the fixture and a stop wall at the other end of the fixture. The hot members may have a T-shape and the cold members an hourglass shape to facilitate heat transfer. The direction of heat transfer through the hot members may be perpendicular to the direction of heat transfer through the cold members, and both of these heat transfer directions maybe perpendicular to the direction-of current flow through the module.

Pento, Robert; Marks, James E.; Staffanson, Clifford D.

1998-07-28T23:59:59.000Z

454

Imaging and spectroscopic observations of magnetic reconnection and chromospheric evaporation in a solar flare  

E-Print Network [OSTI]

Magnetic reconnection is believed to be the dominant energy release mechanism in solar flares. The standard flare model predicts both downward and upward outflow plasmas with speeds close to the coronal Alfv\\'{e}n speed. Yet, spectroscopic observations of such outflows, especially the downflows, are extremely rare. With observations of the newly launched Interface Region Imaging Spectrograph (IRIS), we report the detection of greatly redshifted ($\\sim$125 km s$^{-1}$ along line of sight) Fe {\\sc{xxi}} 1354.08\\AA{} emission line with a $\\sim$100 km s$^{-1}$ nonthermal width at the reconnection site of a flare. The redshifted Fe {\\sc{xxi}} feature coincides spatially with the loop-top X-Ray source observed by the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI). We interpret this large redshift as the signature of downward-moving reconnection outflow/hot retracting loops. Imaging observations from both IRIS and the Atmospheric Imaging Assembly (AIA) onboard the Solar Dynamics Observatory (SDO) also...

Tian, Hui; Reeves, Katharine K; Raymond, John C; Guo, Fan; Liu, Wei; Chen, Bin; Murphy, Nicholas A

2014-01-01T23:59:59.000Z

455

RHEOLOGICAL AND ELEMENTAL ANALYSES OF SIMULANT SB5 SLURRY MIX EVAPORATOR-MELTER FEED TANK SLURRIES  

SciTech Connect (OSTI)

The Defense Waste Processing Facility (DWPF) will complete Sludge Batch 5 (SB5) processing in fiscal year 2010. DWPF has experienced multiple feed stoppages for the SB5 Melter Feed Tank (MFT) due to clogs. Melter throughput is decreased not only due to the feed stoppage, but also because dilution of the feed by addition of prime water (about 60 gallons), which is required to restart the MFT pump. SB5 conditions are different from previous batches in one respect: pH of the Slurry Mix Evaporator (SME) product (9 for SB5 vs. 7 for SB4). Since a higher pH could cause gel formation, due in part to greater leaching from the glass frit into the supernate, SRNL studies were undertaken to check this hypothesis. The clogging issue is addressed by this simulant work, requested via a technical task request from DWPF. The experiments were conducted at Aiken County Technology Laboratory (ACTL) wherein a non-radioactive simulant consisting of SB5 Sludge Receipt and Adjustment Tank (SRAT) product simulant and frit was subjected to a 30 hour SME cycle at two different pH levels, 7.5 and 10; the boiling was completed over a period of six days. Rheology and supernate elemental composition measurements were conducted. The caustic run exhibited foaming once, after 30 minutes of boiling. It was expected that caustic boiling would exhibit a greater leaching rate, which could cause formation of sodium aluminosilicate and would allow gel formation to increase the thickness of the simulant. Xray Diffraction (XRD) measurements of the simulant did not detect crystalline sodium aluminosilicate, a possible gel formation species. Instead, it was observed that caustic conditions, but not necessarily boiling time, induced greater thickness, but lowered the leach rate. Leaching consists of the formation of metal hydroxides from the oxides, formation of boric acid from the boron oxide, and dissolution of SiO{sub 2}, the major frit component. It is likely that the observed precipitation of Mg(OH){sub 2} and Mn(OH){sub 2} caused the increase in yield stress. The low pH run exhibited as much as an order of magnitude greater B and Li (frit components) leachate concentrations in the supernate. At high pH a decrease of B leaching was found and this was attributed to adsorption onto Mg(OH){sub 2}. A second leaching experiment was performed without any sludge to deconvolute the leach rate behavior of Frit 418 from those of the SB5 sludge-Frit 418 system. At high pH, the sludgeless system demonstrated very fast leaching of all the frit components, primarily due to fast dissolution of the main component, silica, by hydroxide anion; various semiconductor studies have established this reactivity. Overall, the frit-water system exhibited greater leaching from a factor two to almost three orders of magnitude (varying by conditions and species). The slower leaching of the sludge system is possibly due to a greater ionic strength or smaller driving force. Another possible reason is a physical effect, coating of the frit particles with sludge; this would increase the mass transfer resistance to leaching. Based on this study, the cause of clogs in the melter feed loop is still unknown. A possible explanation is that the SME product, like the simulant, is too thin and could contribute to a loss of two-phase flow which could cause plugging of a restricted and poorly mixed zone like the melter feed loop. This is feasible since a previous study of a slurry showed an increase in resistance to flow at lower flow rates. Testing with a radioactive SME sample is underway and should help understand this potential mechanism.

Fernandez, A.

2010-02-08T23:59:59.000Z

456

Final characterization and safety screen report of double shell tank 241-AP-105 for evaporator campaign 97-1  

SciTech Connect (OSTI)

Evaporator candidate feed from tank 241-AP-105 (hereafter referred to as AP-105) was characterized for physical, inorganic, organic and radiochemical parameters by the 222-S Laboratory as directed by the Tank Sample and Analysis Plan (TSAP), References 1 through 4, and Engineering Change Notice, number 635332, Reference 5. This data package satisfies the requirement for a format IV, final report as described in Reference 1. This data package is also a follow-up to the 45-Day safety screen results for tank AP-105, Reference 8, which was issued on November 5, 1996, and is attached as Section II to this report. Preliminary data in the form of summary analytical tables were provided to the project in advance of this final report to enable early estimation of evaporator operational parameters, using the Predict modeling program. Analyses were performed at the 222-S Laboratory as defined and specified in the TSAP and the Laboratory's Quality Assurance P1an, References 6 and 7. Any deviations from the instructions documented in the TSAP are discussed in this narrative and are supported with additional documentation.

Miller, G.L.

1997-01-20T23:59:59.000Z

457

High-level waste storage tank farms/242-A evaporator standards/requirements identification document (S/RID), Vol. 4  

SciTech Connect (OSTI)

Radiation protection of personnel and the public is accomplished by establishing a well defined Radiation Protection Organization to ensure that appropriate controls on radioactive materials and radiation sources are implemented and documented. This Requirements Identification Document (RID) applies to the activities, personnel, structures, systems, components, and programs involved in executing the mission of the Tank Farms. The physical boundaries within which the requirements of this RID apply are the Single Shell Tank Farms, Double Shell Tank Farms, 242-A Evaporator-Crystallizer, 242-S, T Evaporators, Liquid Effluent Retention Facility (LERF), Purgewater Storage Facility (PWSF), and all interconnecting piping, valves, instrumentation, and controls. Also included is all piping, valves, instrumentation, and controls up to and including the most remote valve under Tank Farms control at any other Hanford Facility having an interconnection with Tank Farms. The boundary of the structures, systems, components, and programs to which this RID applies, is defined by those that are dedicated to and/or under the control of the Tank Farms Operations Department and are specifically implemented at the Tank Farms.

Not Available

1994-04-01T23:59:59.000Z

458

Habitable Evaporated Cores: Transforming Mini-Neptunes into Super-Earths in the Habitable Zones of M Dwarfs  

E-Print Network [OSTI]

We show that photoevaporation of small gaseous exoplanets ("mini-Neptunes") in the habitable zones of M dwarfs can remove several Earth masses of hydrogen and helium from these planets and transform them into potentially habitable worlds. We couple X-ray/extreme ultraviolet (XUV)-driven escape, thermal evolution, tidal evolution and orbital migration to explore the types of systems that may harbor such "habitable evaporated cores" (HECs). We find that HECs are most likely to form from planets with $\\sim 1 M_\\oplus$ solid cores with up to about 50% H/He by mass, though whether or not a given mini-Neptune forms a HEC is highly dependent on the early XUV evolution of the host star. As terrestrial planet formation around M dwarfs by accumulation of local material is likely to form planets that are small and dry, evaporation of small migrating mini-Neptunes could be one of the dominant formation mechanisms for volatile-rich Earths around these stars.

Luger, Rodrigo; Lopez, Eric; Fortney, Jonathan; Jackson, Brian; Meadows, Victoria

2015-01-01T23:59:59.000Z

459

Understanding Atom Probe Tomography of Oxide-Supported Metal Nanoparticles by Correlation with Atomic Resolution Electron Microscopy and Field Evaporation Simulation  

SciTech Connect (OSTI)

Metal-dielectric composite materials, specifically metal nanoparticles supported on or embedded in metal oxides, are widely used in catalysis. The accurate optimization of such nanostructures warrants the need for detailed three-dimensional characterization. Atom probe tomography is uniquely capable of generating sub-nanometer structural and compositional data with part-per-million mass sensitivity, but there are reconstruction artifacts for composites containing materials with strongly differing fields of evaporation, as for oxide-supported metal nanoparticles. By correlating atom probe tomography with scanning transmission electron microscopy for Au nanoparticles embedded in an MgO support, deviations from an ideal topography during evaporation are demonstrated directly, and correlated with compositional errors in the reconstructed data. Finite element simulations of the field evaporation process confirm that protruding Au nanoparticles will evolve on the tip surface, and that evaporation field variations lead to an inaccurate assessment of the local composition, effectively lowering the spatial resolution of the final reconstructed dataset. Cross-correlating the experimental data with simulations results in a more detailed understanding of local evaporation aberrations during APT analysis of metal-oxide composites, paving the way towards a more accurate three-dimensional characterization of this technologically important class of materials.

Devaraj, Arun; Colby, Robert J.; Vurpillot, F.; Thevuthasan, Suntharampillai

2014-03-26T23:59:59.000Z

460

Milestone Report #2: Direct Evaporator Leak and Flammability Analysis Modifications and Optimization of the Organic Rankine Cycle to Improve the Recovery of Waste Heat  

SciTech Connect (OSTI)

The direct evaporator is a simplified heat exchange system for an Organic Rankine Cycle (ORC) that generates electricity from a gas turbine exhaust stream. Typically, the heat of the exhaust stream is transferred indirectly to the ORC by means of an intermediate thermal oil loop. In this project, the goal is to design a direct evaporator where the working fluid is evaporated in the exhaust gas heat exchanger. By eliminating one of the heat exchangers and the intermediate oil loop, the overall ORC system cost can be reduced by approximately 15%. However, placing a heat exchanger operating with a flammable hydrocarbon working fluid directly in the hot exhaust gas stream presents potential safety risks. The purpose of the analyses presented in this report is to assess the flammability of the selected working fluid in the hot exhaust gas stream stemming from a potential leak in the evaporator. Ignition delay time for cyclopentane at temperatures and pressure corresponding to direct evaporator operation was obtained for several equivalence ratios. Results of a computational fluid dynamic analysis of a pinhole leak scenario are given.

Donna Post Guillen

2013-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "lined evaporation pond" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Post-Closure Inspection Report for Corrective Action Unit 92: Area 6 Decon Pond Facility, Nevada Test Site, Nevada, for Calendar Year 2006  

SciTech Connect (OSTI)

This Post-Closure Inspection Report provides an analysis and summary of inspections for Corrective Action Unit (CAU) 92, Area 6 Decon Pond Facility. CAU 92 was closed according to the ''Resource Conservation and Recovery Act'' (RCRA) Part B Operational Permit (Nevada Division of Environmental Protection [NDEP], 1995) and the ''Federal Facility Agreement and Consent Order'' (FFACO) of 1996 (FFACO, 1996). Closure activities were completed on February 16, 1999, and the Closure Report (U.S. Department of Energy, Nevada Operations Office, 1999) was approved and a Notice of Completion issued by NDEP on May 11, 1999. CAU 92 consists of two Corrective Action Sites (CASs), CAS 06-04-01, Decon Pad Oil/Water Separator; and CAS 06-05-02, Decontamination Pond (RCRA). Both CASs have use restrictions; however, only CAS 06-05-02 requires post-closure inspections. Visual inspections of the cover and fencing at CAS 06-05-02 are performed quarterly. Additional inspections are conducted if precipitation occurs in excess of 1.28 centimeters (cm) (0.50 inches [in.]) in a 24-hour period. This report covers calendar year 2006. Quarterly site inspections were performed in March, June, September, and December of 2006. All observations indicated the continued integrity of the unit. No issues or concerns were noted, and no corrective actions were necessary. Copies of the inspection checklists and field notes completed during each inspection are included in Appendix A of this report, and photographs taken during the site inspections are included in Appendix B of this report. One additional inspection was performed after a precipitation event that exceeded 1.28 cm (0.50 in.) within a 24-hour period during 2006. No significant changes in site conditions were noted during this inspection, and no corrective actions were necessary. A copy of the inspection checklist and field notes completed during this additional inspection is included in Appendix A of this report. Precipitation records for 2006 are included in Appendix C of this report.

NSTec Environmental Restoration

2007-03-01T23:59:59.000Z

462

Remedial investigation report on Chestnut Ridge Operable Unit 2 (filled coal ash pond/Upper McCoy Branch) at the Oak Ridge Y-12 Plant, Oak Ridge, Tennessee. Volume 2: Appendixes  

SciTech Connect (OSTI)

This report comprises appendices A--J which support the Y-12 Plant`s remedial action report involving Chestnut Ridge Operable Unit 2 (filled coal ash pond/Upper McCoy Branch). The appendices cover the following: Sampling fish from McCoy Branch; well and piezometer logs; ecological effects of contaminants in McCoy Branch 1989-1990; heavy metal bioaccumulation data; microbes in polluted sediments; and baseline human health risk assessment data.

Not Available

1994-08-01T23:59:59.000Z

463

Mud return line connector apparatus  

SciTech Connect (OSTI)

The preferred and illustrated embodiment is a connector adapted to be joined above a blowout preventer and below the rotary table of a drilling rig. It collects the annular flow of returned drilling mud and directs mud to an incorporated, radially directed connective nipple. It enables the blowout preventer to be adjusted in location relative to the drilling rig and further accommodates a variable level of drilling mud in the annular space. The radial nipple connects with a mud line extending at some radial direction with a slope causing the mud to flow by gravity from the annular space to remote located mud tanks.

Ward, B.N.

1981-07-07T23:59:59.000Z

464

Chromospheric Dynamics and Line Formation  

E-Print Network [OSTI]

The solar chromosphere is very dynamic, due to the presence of large amplitude hydrodynamic waves. Their propagation is affected by NLTE radiative transport in strong spectral lines, which can in turn be used to diagnose the dynamics of the chromosphere. We give a basic introduction into the equations of NLTE radiation hydrodynamics and describe how they are solved in current numerical simulations. The comparison with observation shows that one-dimensional codes can describe strong brightenings quite well, but the overall chromospheric dynamics appears to be governed by three-dimensional shock propagation.

R. Hammer; P. Ulmschneider

2007-07-14T23:59:59.000Z

465

SPEAR3 Beam Line Availability  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the1 -the Mid-Infrared0 ResourceAwards SAGE Awards ,#2446Smalln n u a l rBeam Line

466

Capillary electrophoresis-fluorescence line narrowing system (CE-FLNS) for on-line structural characterization  

DOE Patents [OSTI]

Capillary electrophoresis (CE) is interfaced with low temperature fluorescence line-narrowing (FLN) spectroscopy for on-line structural characterization of separated molecular analytes. 21 figs.

Jankowiak, R.J.; Small, G.J.; Shields, P.A.

1999-04-27T23:59:59.000Z

467

Line Management Perspective: National Nuclear Security Administration...  

Broader source: Energy.gov (indexed) [DOE]

National Nuclear Security Administration (NNSA) Line Management Perspective: National Nuclear Security Administration (NNSA) Addthis Description Slide Presentation by Jim...

468

Title Line 2 Commercialization at the  

E-Print Network [OSTI]

-exclusive or exclusive license (royalty free or royalty bearing) ­ Researchers sign acknowledgment #12;Title Title Line 2

Czarnecki, Krzysztof

469

Refractory Lining Material Improves Gasifer Performance  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

water GASIFICATION CHAMBER the ENERGY lab NATIONAL ENERGY TECHNOLOGY LABORATORY Technology Transfer Refractory Lining Material Improves Gasifier Performance Award Winning...

470

Methods of Using Existing Wire Lines (power lines, phone lines, internet lines) for Totally Secure Classical Communication Utilizing Kirchoff's Law and Johnson-like Noise  

E-Print Network [OSTI]

We outline some general solutions to use already existing and currently used wire lines, such as power lines, phone lines, internet lines, etc, for the unconditionally secure communication method based on Kirchoff's Law and Johnson-like Noise (KLJN). Two different methods are shown. One is based on filters used at single wires and the other one utilizes a common mode voltage superimposed on a three-phase powerline.

Laszlo B. Kish

2006-10-02T23:59:59.000Z

471

Quality assurance project plan for the Chestnut Ridge Fly Ash Pond Stabilization Project at the Oak Ridge Y-12 Plant, Oak Ridge, Tennessee  

SciTech Connect (OSTI)

The Chestnut Ridge Fly Ash Pond Stabilization (CRFAPS) Project will stabilize a 19-m-high (62-ft-high) earthen embankment across Upper McCoy Branch situated along the southern slope of Chestnut Ridge. This task will be accomplished by raising the crest of the embankment, reinforcing the face of the embankment, removing trees from the face and top of the embankment, and repairing the emergency spillway. The primary responsibilities of the team members are: Lockheed Martin Energy Systems, Inc., (Energy Systems) will be responsible for project integration, technical support, Title 3 field support, environmental oversight, and quality assurance (QA) oversight of the project; Foster Wheeler Environmental Corporation (FWENC) will be responsible for design and home office Title 3 support; MK-Ferguson of Oak Ridge Company (MK-F) will be responsible for health and safety, construction, and procurement of construction materials. Each of the team members has a QA program approved by the US Department of Energy (DOE) Oak Ridge Operations. This project-specific QA project plan (QAPP), which is applicable to all project activities, identifies and integrates the specific QA requirements from the participant`s QA programs that are necessary for this project.

NONE

1996-07-01T23:59:59.000Z

472

Use of Air2Air Technology to Recover Fresh-Water from the Normal Evaporative Cooling Loss at Coal-Based Thermoelectric Power Plants  

SciTech Connect (OSTI)

This program was undertaken to build and operate the first Air2Air{trademark} Water Conservation Cooling Tower at a power plant, giving a validated basis and capability for water conservation by this method. Air2Air{trademark} water conservation technology recovers a portion of the traditional cooling tower evaporate. The Condensing Module provides an air-to-air heat exchanger above the wet fill media, extracting the heat from the hot saturated moist air leaving in the cooling tower and condensing water. The rate of evaporate water recovery is typically 10%-25% annually, depending on the cooling tower location (climate).

Ken Mortensen

2009-06-30T23:59:59.000Z

473

Unsplit bipolar pulse forming line  

DOE Patents [OSTI]

A bipolar pulse forming transmission line module and system for linear induction accelerators having first, second, third, and fourth planar conductors which form a sequentially arranged interleaved stack having opposing first and second ends, with dielectric layers between the conductors. The first and second planar conductors are connected to each other at the first end, and the first and fourth planar conductors are connected to each other at the second end via a shorting plate. The third planar conductor is electrically connectable to a high voltage source, and an internal switch functions to short at the first end a high voltage from the third planar conductor to the fourth planar conductor to produce a bipolar pulse at the acceleration axis with a zero net time integral. Improved access to the switch is enabled by an aperture through the shorting plate and the proximity of the aperture to the switch.

Rhodes, Mark A. (Pleasanton, CA)

2011-05-24T23:59:59.000Z

474

Superconducting transmission line particle detector  

DOE Patents [OSTI]

A microvertex particle detector for use in a high energy physic collider including a plurality of parallel superconducting thin film strips separated from a superconducting ground plane by an insulating layer to form a plurality of superconducting waveguides. The microvertex particle detector indicates passage of a charged subatomic particle by measuring a voltage pulse measured across a superconducting waveguide caused by the transition of the superconducting thin film strip from a superconducting to a non- superconducting state in response to the passage of a charged particle. A plurality of superconducting thin film strips in two orthogonal planes plus the slow electromagnetic wave propagating in a superconducting transmission line are used to resolve N/sup 2/ ambiguity of charged particle events. 6 figs.

Gray, K.E.

1988-07-28T23:59:59.000Z

475

Gamma-Ray Burst Lines  

E-Print Network [OSTI]

The evidence for spectral features in gamma-ray bursts is summarized. As a guide for evaluating the evidence, the properties of gamma-ray detectors and the methods of analyzing gamma-ray spectra are reviewed. In the 1980's, observations indicated that absorption features below 100 keV were present in a large fraction of bright gamma-ray bursts. There were also reports of emission features around 400 keV. During the 1990's the situation has become much less clear. A small fraction of bursts observed with BATSE have statistically significant low-energy features, but the reality of the features is suspect because in several cases the data of the BATSE detectors appear to be inconsistent. Furthermore, most of the possible features appear in emission rather than the expected absorption. Analysis of data from other instruments has either not been finalized or has not detected lines.

Michael S. Briggs

1999-10-20T23:59:59.000Z

476

Superconducting transmission line particle detector  

DOE Patents [OSTI]

A microvertex particle detector for use in a high energy physic collider including a plurality of parallel superconducting thin film strips separated from a superconducting ground plane by an insulating layer to form a plurality of superconducting waveguides. The microvertex particle detector indicates passage of a charged subatomic particle by measuring a voltage pulse measured across a superconducting waveguide caused by the transition of the superconducting thin film strip from a superconducting to a non-superconducting state in response to the passage of a charged particle. A plurality of superconducting thin film strips in two orthogonal planes plus the slow electromagnetic wave propogating in a superconducting transmission line are used to resolve N.sup.2 ambiguity of charged particle events.

Gray, Kenneth E. (Naperville, IL)

1989-01-01T23:59:59.000Z

477

Interaction of CO molecules with evaporated silver, gold, and copper films: an infrared spectroscopic investigation using a thermal detection technique  

SciTech Connect (OSTI)

We have used infrared absorption spectroscopy to study the adsorption of CO at low temperatures on evaporated films of silver, gold, and copper as a function of the coverage of CO and the deposition temperature of the metal. For all three metals we observe two distinct adsorption regimes when the cold metal is exposed to CO gas. These regimes arise depending on whether the deposition temperature of the metal (or the highest temperature at which the metal has been annealed) is above or below a threshold temperature. For all three metals, the shift of the vibrational frequency with CO coverage has been analyzed, and the static and dynamic contributions separated. An analysis of infrared intensities and vibrational polarizabilities shows no evidence for any special infrared enhancement analogous to the large enhancement in Raman cross section peculiar to adsorption on rough noble metal films deposited at low temperatures.

Dumas, P.; Tobin, R.G.; Richards, P.L.

1985-09-01T23:59:59.000Z