Sample records for lighting roofs steam-system

  1. White Roofs

    ScienceCinema (OSTI)

    Chu, Steven

    2013-05-29T23:59:59.000Z

    Secretary Steven Chu discusses the benefits of switching to white roofs and light colored pavements.

  2. Steam System Data Management

    E-Print Network [OSTI]

    Roberts, D.

    2013-01-01T23:59:59.000Z

    Steam System Data Management What Does It Include Safety In Motion Wal?Tech?Valve,?Inc. 251?438?2203 The Real Genius Behind Technology Is People ESL-IE-13-05-35 Proceedings of the Thrity-Fifth Industrial Energy Technology Conference New... ? Fabrication Training (Six Year Training) ? Welding Certifications ?Retired From Chevron After 25 Years ? Established A Steam System Program ? Planner For Routine Maintenance Work ? Planner For Steam System Improvements ? Wal-Tech Valve, Inc. ? Purchased...

  3. Cooling energy savings potential of light-colored roofs for residential and commercial buildings in 11 US metropolitan areas

    SciTech Connect (OSTI)

    Konopacki, S.; Akbari, H.; Pomerantz, M.; Gabersek, S.; Gartland, L.

    1997-05-01T23:59:59.000Z

    Light-colored roofs reflect more sunlight than dark roofs, thus they keep buildings cooler and reduce air-conditioning demand. Typical roofs in the United States are dark, which creates a potential for savings energy and money by changing to reflective roofs. In this report, the authors make quantitative estimates of the impact of roof color by simulating prototypical buildings with light- and dark-colored roofs and calculating savings by taking the differences in annual cooling and heating energy use, and peak electricity demand. Monetary savings are calculated using local utility rates. Savings are estimated for 11 U.S. Metropolitan Statistical Areas (MSAs) in a variety of climates.

  4. Metal roofing Shingle roofing

    E-Print Network [OSTI]

    Hutcheon, James M.

    Metal roofing panel Shingle roofing Water & ice barrier Thermal Barrier Plywood Student: Arpit between the roof and the attic. · Apply modifications to traditional roofing assembly and roofing roof with only a water barrier between the plywood and the roofing panels. Metal roofing panel Shingle

  5. Steam System Tool Suite Introduction Guide

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    Steam System Tool Suite Introduction Guide Alternate Text Narratives and Graphic.............................................................................................................................6 Modules Steam System Scoping Tool (SSST)........................................................................................8 Steam System Assessment Tool (SSAT

  6. Steam System Optimization 

    E-Print Network [OSTI]

    Aegerter, R.

    2004-01-01T23:59:59.000Z

    Refinery and chemical plant steam systems are complex and the fuel required to produce the steam represents a major expense. The incremental cost for generating a 1,000 lb./hr. of steam is typically $45,000 - $60,000/year. Most plants have...

  7. Deaerators in Industrial Steam Systems

    SciTech Connect (OSTI)

    Not Available

    2006-01-01T23:59:59.000Z

    This revised ITP tip sheet on deaerators in industrial steam systems provides how-to advice for improving industrial steam systems using low-cost, proven practices and technologies.

  8. Steam System Forecasting and Management

    E-Print Network [OSTI]

    Mongrue, D. M.; Wittke, D. O.

    1982-01-01T23:59:59.000Z

    '. This and the complex and integrated nature of the plants energy balance makes steam system forecasting and management essential for optimum use of the plant's energy. This paper discusses the method used by Union carbide to accomplish effective forecasting...

  9. Steam Systems | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33Frequently AskedEnergyIssues DOE's NuclearSpurringSteam Systems Steam Systems Many

  10. Training: Steam Systems | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    Steam Systems Training: Steam Systems April 16, 2014 - 6:31pm Addthis Learn about the diverse training sessions offered. The courses are taught by highly qualified instructors who...

  11. Steam System Improvements at a Manufacturing Plant

    E-Print Network [OSTI]

    Compher, J.; Morcom, B.

    BWX Technologies, Naval Nuclear Fuel Division (NNFD) is a manufacturing company with a steam system consisting of two Babcock & Wilcox boilers and approximately 350 steam traps. The steam system is used to produce and distribute steam for space...

  12. Achieve Steam System Excellence - Steam Overview | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: The Future of1 AAccelerated aging of roofingDepartmentAchieve Steam System

  13. SteamMaster: Steam System Analysis Software 

    E-Print Network [OSTI]

    Wheeler, G.

    2003-01-01T23:59:59.000Z

    recommendations to increase steam system effic iency. Steam System Opportunities ]n nearly 400 industrial assessments, we have recommended 210 steam system improvements, excluding heat recovery, that would save $1.5 million/year with a O.4-year payback. 75...

  14. Demonstration of Energy Savings of Cool Roofs

    E-Print Network [OSTI]

    Konopacki, S.

    2010-01-01T23:59:59.000Z

    Savings of High-Albedo Roofs. Energy and Buildings, vol. 25,Cooling Savings of Light Colored Roof Surfacing in FloridaInfra-red photograph of roof-coating edge at Gilroy. This

  15. Roof Renovations

    Broader source: Energy.gov [DOE]

    The roof of a Federal building is a common placement for a number of renewable energy technologies, so they should be addressed anytime a roof renovation is undertaken, including roof-mounted...

  16. Improving Steam System Performance: A Sourcebook for Industry...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Improving Steam System Performance: A Sourcebook for Industry, Second Edition Improving Steam System Performance: A Sourcebook for Industry, Second Edition This sourcebook is...

  17. Dow Chemical Company: Assessment Leads to Steam System Energy...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Dow Chemical Company: Assessment Leads to Steam System Energy Savings in a Petrochemical Plant Dow Chemical Company: Assessment Leads to Steam System Energy Savings in a...

  18. Steam System Efficiency Optimized After J.R. Simplot Fertilizer...

    Broader source: Energy.gov (indexed) [DOE]

    Steam System Efficiency Optimized After J.R. Simplot Fertilizer Plant Receives Energy Assessment Steam System Efficiency Optimized After J.R. Simplot Fertilizer Plant Receives...

  19. Steam System Improvement: A Case Study

    E-Print Network [OSTI]

    Venkatesan, V. V.; Leigh, N.

    . For industries, this will result in the reduction of production cost. In industry where steam is utilized, the steam production and distribution system consumes a significant portion of energy. Therefore, optimization of steam system is among the biggest energy...

  20. The Steam System Assessment Tool (SSAT): Estimating Steam System Energy, Cost, and Emission Savings

    E-Print Network [OSTI]

    Wright, A.; Bealing, C.; Eastwood, A.; Tainsh, R.; Hahn, G.; Harrell, G.

    The U. S. Department of Energy's (DOE) Industrial Technology Program BestPractices Steam effort is developing a number of software tools to assist industrial energy users to improve the efficiency of their steam system. A major new Best...

  1. A ROOFING TILE FOR NATURAL COOLING

    E-Print Network [OSTI]

    SUNGUARD: A ROOFING TILE FOR NATURAL COOLING Prepared For: California Energy Commission Energy (FAR) SUNGUARD: A ROOFING TILE FOR NATURAL COOLING EISG AWARDEE PowerLight Corporation 2954 San Pablo://www.energy.ca.gov/research/index.html. #12;Page 1 Sunguard: A Roofing Tile For Natural Cooling EISG Grant # 99-07 Awardee: Power

  2. Steam System Optimization: A Case Study

    E-Print Network [OSTI]

    Iordanova, N.; Venkatesan, V. V.

    /hr is imported from an outside power plant and 170,000 lbslhr is internally generated as waste heat recovery. The steam system analysis identified energy savings worth of $2,400,000 per year. The optimization measures were in two categories: ? no cost / low... cost that can be done through better maintenance and improvement of operating conditions. ? major improvement that requires a significant amount of investment, that includes the modification of process and major equipment. Though the findings...

  3. Photovoltaic roof heat flux

    E-Print Network [OSTI]

    Samady, Mezhgan Frishta

    2011-01-01T23:59:59.000Z

    e l Atmosphere ceiling, back panel roof, exposed roof insideSAN DIEGO Photovoltaic Roof Heat Flux A Thesis submitted i no n Convection Exposed Roof Temperature Seasonal Temperature

  4. Using Green Roofs to Minimize Roof Runoff Pollution

    E-Print Network [OSTI]

    Clark, Shirley E.

    10/31/2008 1 Using Green Roofs to Minimize Roof Runoff Pollution Brett LongBrett Long Shirley Clark Courtesy Penn State Center for Green Roof Research Green Roofs:Green Roofs: The New BMP (at least in the US)The New BMP (at least in the US) Green roofs = vegetated roof coversGreen roofs = vegetated roof covers Pl

  5. Ethnography of Cool Roof Retrofits: The Role of Rebates in the Materials Selection Process

    E-Print Network [OSTI]

    Mazur-Stommen, Susan

    2014-01-01T23:59:59.000Z

    mind  when  I  say  ‘cool  roof’?   “Light  color.  Long  the  idea  for  a  cool  roof?   What  kind  of  research  the  idea  for  a  cool  roof?   Where  did  you  first  

  6. Procedure for measuring the solar reflectance of flat or curved roofing assemblies

    E-Print Network [OSTI]

    Akbari, Hashem

    2008-01-01T23:59:59.000Z

    energy-use effects of cool roofs on California commercialfrom the application of reflective roofs in two small non-saving potentials of light-colored roofs for residential and

  7. ORNL/TM-2001/263 Steam System Survey Guide

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    ORNL/TM-2001/263 Steam System Survey Guide Greg Harrell, Ph.D., P.E. #12;DOCUMENT AVAILABILITY Government or any agency thereof. #12;ORNL/TM-2001/263 STEAM SYSTEM SURVEY GUIDE Greg Harrell, Ph.D., P for the U.S. Department of Energy BestPractices Steam Program Prepared by OAK RIDGE NATIONAL LABORATORY Oak

  8. advanced steam systems: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    steam systems First Page Previous Page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Next Page Last Page Topic Index 1 Steam System Optimization Texas A&M...

  9. Cool Roofs Webinar

    Broader source: Energy.gov [DOE]

    A webinar presented by Blaise Stoltenberg and Kosol Kiatreungwattana of the National Renewable Energy Laboratory about roofs designed to maintain a lower roof temperature than traditional roofs in order to reduce energy bills.

  10. The Effects of Roof Membrane Color on Moisture Accumulation in Low-slope Commercial Roof Systems

    SciTech Connect (OSTI)

    Kehrer, Manfred [ORNL

    2011-01-01T23:59:59.000Z

    The use of highly reflective roof membrane systems is being promoted and in some cases required in energy codes and green building codes and standards. Highly reflective membranes, which typically are light in color, have demonstrated reduced overall energy consumption in cooling dominated climate. These membranes also are theorized to reduce the heat island effect. Concern has been expressed about using highly reflective roof membrane systems in cool to cold climate zones because they potentially increase moisture accumulation in roof systems. Roof membranes are vapor retarders. The theory is that highly reflective membranes reflect the heat that could enter the roof assembly, potentially providing a condensing surface on the cold side of the roof assembly during winter months. The other concern is that roof systems using highly reflective membranes will not get hot enough during the summer months to dry out moisture that may have condensed or otherwise entered the roof assembly. This study focuses on mechanically attached, highly reflective, single-ply roof systems installed on low-slope (less than 2:12) structures in cool to cold climate zones. Three sources of data are considered when determining the moisture accumulation potential of these systems. 1.Test roof cuts taken during the winter months 2.Modeling data from a building envelope model specifically designed to evaluate moisture accumulation 3.Data from previous studies to determine the effects of roof membrane color on the drying rate of low-slope roof assemblies

  11. Photovoltaic roof heat flux

    E-Print Network [OSTI]

    Samady, Mezhgan Frishta

    2011-01-01T23:59:59.000Z

    temperature between the solar panel and the roof would havedirectly underneath the solar panel, and the temperatures ofsensor between the solar panel and the roof for the flush

  12. Practical Approach to Designing Wood Roof Truss Assemblies

    E-Print Network [OSTI]

    Gupta, Rakesh

    Practical Approach to Designing Wood Roof Truss Assemblies Rakesh Gupta, M.ASCE1 ; and Pranueng to evaluate "system effects" in light-frame roof truss assemblies. The goal of this study was to develop an improved and practical design method for 3D roof truss assemblies used in residential construction. A truss

  13. Roof bolting improvements

    SciTech Connect (OSTI)

    Fiscor, S.

    2008-11-15T23:59:59.000Z

    Suppliers partner with mine operators to offer safer, more productive tools for roof bolting. 4 figs.

  14. Boiler Upgrades and Decentralizing Steam Systems Save Water and...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Steam Systems Save Water and Energy at Naval Air Station Oceana Case study details Naval Air Station Oceana findings that its heating needs could be met more efficiently by...

  15. Steam Power Partnership: Improving Steam System Efficiency Through Marketplace Partnerships

    E-Print Network [OSTI]

    Jones, T.

    The Alliance to Save Energy, a national nonprofit organization based in Washington DC, and the U.S. Department of Energy are working with energy efficiency suppliers to promote the comprehensive upgrade of industrial steam systems. Like EPA's Green...

  16. The Analysis and Development of Large Industrial Steam Systems

    E-Print Network [OSTI]

    Waterland, A. F.

    1980-01-01T23:59:59.000Z

    Chemicals, petroleum, pulp and paper, and many other industries depend heavily on extensive complex steam systems for thermal and mechanical energy delivery. Steam's versatility and desirable characteristics as both a heat transfer medium and a...

  17. Photovoltaic roof heat flux

    E-Print Network [OSTI]

    Samady, Mezhgan Frishta

    2011-01-01T23:59:59.000Z

    designs (relatively) Photovoltaic Solar P a n e l AtmosphereCALIFORNIA, SAN DIEGO Photovoltaic Roof Heat Flux A ThesisABSTRACT OF T H E THESIS Photovoltaic Roof Heat Flux by

  18. Impact of Reflective Roofing on Cooling Electrical Use and Peak Demand in a Florida Retail Mall

    E-Print Network [OSTI]

    Parker, D. S.; Sonne, J. K.; Sherwin, J. R.

    2002-01-01T23:59:59.000Z

    . Experimental Plan To isolate the impact of adding a reflective roof surface, a before-and-after experimental protocol was used. With this experimental approach, a period of base line data is collected on the space cooling performance at the facility... roof resurfacing. Firstly, a potential utility program would want to target facilities for a light colored roof that were involved in re-roofing. Whereas discretionary change to a white roof costs approximately $0.50/ft2, the incremental cost...

  19. Roof Coating Procedures and Their Productivity Gains

    E-Print Network [OSTI]

    Bonaby, J.; Schaub, D.

    2006-01-01T23:59:59.000Z

    benefit of the installation of different roof coating technologies and comparable application procedures of these technologies are ambiguous. The focal point of this research is to determine the effective correlation between various commercially... available roof coatings, and productivity gains associated with these energy saving strategies. This type of situation is evidenced in the justification of energy rebates distributed by Florida Power & Light in exchange for the application of Energy Star...

  20. Implementation and Rejection of Industrial Steam System Energy Efficiency Measures

    SciTech Connect (OSTI)

    Therkelesen, Peter; McKane, Aimee

    2013-05-01T23:59:59.000Z

    Steam systems consume approximately one third of energy applied at U.S. industrial facilities. To reduce energy consumption, steam system energy assessments have been conducted on a wide range of industry types over the course of five years through the Energy Savings Assessment (ESA) program administered by the U.S. Department of Energy (U.S. DOE). ESA energy assessments result in energy efficiency measure recommendations that are given potential energy and energy cost savings and potential implementation cost values. Saving and cost metrics that measure the impact recommended measures will have at facilities, described as percentages of facility baseline energy and energy cost, are developed from ESA data and used in analyses. Developed savings and cost metrics are examined along with implementation and rejection rates of recommended steam system energy efficiency measures. Based on analyses, implementation of steam system energy efficiency measures is driven primarily by cost metrics: payback period and measure implementation cost as a percentage of facility baseline energy cost (implementation cost percentage). Stated reasons for rejecting recommended measures are primarily based upon economic concerns. Additionally, implementation rates of measures are not only functions of savings and cost metrics, but time as well.

  1. B.4 ROOF SYSTEMS B.4 Roof System

    E-Print Network [OSTI]

    Gelfond, Michael

    B.4 ROOF SYSTEMS B.4 Roof System Page 1 of 4 Attachment C 05/07/09 SYSTEM AUDIT INSPECTION REPORT SUMMARY B4-Roof System Facility Name: Facility #: Audit By: Audit Date: SYSTEM CONDITION RATING WORK ORDER/CIP # #12;B.4 ROOF SYSTEMS B.4 Roof System Page 2 of 4 Attachment C 05/07/09 Sub

  2. IMPROVED ROOF STABILIZATION TECHNOLOGIES

    SciTech Connect (OSTI)

    M.A. Ebadian, Ph.D.

    1999-01-01T23:59:59.000Z

    Many U.S. Department of Energy (DOE) remediation sites have performed roof repair and roof replacement to stabilize facilities prior to performing deactivation and decommissioning (D&D) activities. This project will review the decision criteria used by these DOE sites, along with the type of repair system used for each different roof type. Based on this information, along with that compiled from roofing experts, a decision-making tool will be generated to aid in selecting the proper roof repair systems. Where appropriate, innovative technologies will be reviewed and applied to the decision-making tool to determine their applicability. Based on the results, applied research and development will be conducted to develop a method to repair these existing roofing systems, while providing protection for the D and D worker in a cost-efficient manner.

  3. Energy 101: Cool Roofs

    ScienceCinema (OSTI)

    None

    2013-05-29T23:59:59.000Z

    This edition of Energy 101 takes a look at how switching to a cool roof can save you money and benefit the environment.

  4. Energy 101: Cool Roofs

    SciTech Connect (OSTI)

    None

    2011-01-01T23:59:59.000Z

    This edition of Energy 101 takes a look at how switching to a cool roof can save you money and benefit the environment.

  5. Why Cool Roofs?

    ScienceCinema (OSTI)

    Chu, Steven

    2013-05-29T23:59:59.000Z

    By installing a cool roof at DOE, the federal government and Secretary Chu are helping to educate families and businesses about the important energy and cost savings that can come with this simple, low-cost technology. Cool roofs have the potential to quickly and dramatically reduce global carbon emissions while saving money every month on consumers' electrical bills.

  6. Why Cool Roofs?

    SciTech Connect (OSTI)

    Chu, Steven

    2010-01-01T23:59:59.000Z

    By installing a cool roof at DOE, the federal government and Secretary Chu are helping to educate families and businesses about the important energy and cost savings that can come with this simple, low-cost technology. Cool roofs have the potential to quickly and dramatically reduce global carbon emissions while saving money every month on consumers' electrical bills.

  7. Roof bolting equipment & technology

    SciTech Connect (OSTI)

    Fiscor, S.

    2009-04-15T23:59:59.000Z

    Technology provides an evaluator path to improvement for roof bolting machines. Bucyrus offers three different roof bolts models for various mining conditions. The LRB-15 AR is a single-arm boiler recommended for ranges of 32 inches and above; the dual-arm RB2-52A for ranges of 42 inches and above; and the dual-arm RB2-88A for ranges of 54 inches and above. Design features are discussed in the article. Developments in roof bolting technology by Joy Mining Machinery are reported. 4 photos.

  8. Achieve Steam System Excellence - Steam Overview | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the YouTube platform is alwaysISO 50001 Energy ManagementPatriciaUCNIAchieve Steam System

  9. Why Cool Roofs?

    Broader source: Energy.gov [DOE]

    By installing a cool roof at DOE, the federal government and Secretary Chu are helping to educate families and businesses about the important energy and cost savings that can come with this simple,...

  10. Photovoltaic roof heat flux

    E-Print Network [OSTI]

    Samady, Mezhgan Frishta

    2011-01-01T23:59:59.000Z

    under the offset unit's solar panel, the hf formula (16) wasdrop below the angle unit's solar panel at night time. D u rfor both the units, the solar panel covered roof was a heat

  11. Tools to Boost Steam System Efficiency, Software Tools for Industry, Industrial Technologies Program (ITP) (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2008-12-01T23:59:59.000Z

    This fact sheet describes how the Industrial Technologies Program steam software tools can help industrial plants identify steam system improvements to save energy and money.

  12. Rain on the Roof-Evaporative Spray Roof Cooling

    E-Print Network [OSTI]

    Bachman, L. R.

    1985-01-01T23:59:59.000Z

    -air principles are covered and a simplified method of evaluation presented. A life cycle energy savings example is discussed. Benefits of roof life and roof top equipment efficiency and maintenance are covered as well as water consumption and performance trade...

  13. Identifying Steam Opportunity "Impact" Inputs for the Steam System Assessment Tool (SSAT) 

    E-Print Network [OSTI]

    Harrell, G.; Jendrucko, R.; Wright, A.

    2004-01-01T23:59:59.000Z

    The U.S. DOE BestPractices Steam "Steam System Assessment Tool" (SSAT) is a powerful tool for quantifying potential steam improvement opportunities in steam systems. However, all assessment tools are only as good as the validity of the modeling...

  14. Annual Steam System Maintenance Outage (2014) Beginning on Sunday, June 8th

    E-Print Network [OSTI]

    Firestone, Jeremy

    Annual Steam System Maintenance Outage (2014) Beginning on Sunday, June 8th at 12:00pm (Noon), the Central Utility Plant (CUP), which supplies steam service to over 100 buildings on the Newark campus, will be shut down for the annual Steam System Maintenance Outage. This effort is necessary each year to ensure

  15. Solar Roof Cooling by Evaporation

    E-Print Network [OSTI]

    Patterson, G. V.

    1982-01-01T23:59:59.000Z

    Evaporation is nature's way of cooling. By the application of a thin film of water, in the form of a mist, on the roof of the building, roof temperatures can be reduced from as high as 165o to a cool 86oF. Thus, under-roof temperatures are reduced...

  16. Solar Roof Cooling by Evaporation

    E-Print Network [OSTI]

    Patterson, G. V.

    1980-01-01T23:59:59.000Z

    . Roof air conditioning load is reduced by 85% to 90%. The cooler roof also protects and extends roof life. My presentation today will cover an old, square foot, and generally speaking, it will old technique -- one that has been gaining in show a...

  17. Roofs and Convexity

    E-Print Network [OSTI]

    Armin Uhlmann

    2011-08-16T23:59:59.000Z

    Convex roof extensions are widely used to create entanglement measures in quantum information theory. The aim of the article is to present some tools which could be helpful for their treatment. Sections 2 and 3 introduce into the subject. It follows descriptions of Wootter's method, of the "subtraction procedure", and examples on how to use symmetries.

  18. Roofs and Convexity

    E-Print Network [OSTI]

    Uhlmann, Armin

    2011-01-01T23:59:59.000Z

    Convex roof extensions are widely used to create entanglement measures in quantum information theory. The aim of the article is to present some tools which could be helpful for their treatment. Sections 2 and 3 introduce into the subject. It follows descriptions of Wootter's method, of the "subtraction procedure", and examples on how to use symmetries.

  19. \\\\mi\\home\\gillow\\LaTeX\\Comp\\Safety\\Risk-Assessments\\Roof\\Sedum Roof Area Roof Access Risk Assessments 3th March 2014.docx `Sedum' Roof Area(s)/Roof Access Risk Assessments

    E-Print Network [OSTI]

    \\\\mi\\home\\gillow\\LaTeX\\Comp\\Safety\\Risk-Assessments\\Roof\\Sedum Roof Area Roof Access Risk Assessments 3th March 2014.docx `Sedum' Roof Area(s)/Roof Access Risk Assessments DEPARTMENT: Andrew Wiles March 2015 Brief description of area and location Roof tops, walkways, and Fire Route. Sedum' Roof Area

  20. Runoff Quality From Roofing Materials During Early Life

    E-Print Network [OSTI]

    Clark, Shirley E.

    State Harrisburg #12;3 Green Roof vs. Traditional Roof Design Conventional gravel-ballasted roof Green

  1. Generating Electricity with your Steam System: Keys to Long Term Savings

    E-Print Network [OSTI]

    Bullock, B.; Downing, A.

    2010-01-01T23:59:59.000Z

    The application of combined heat and power principals to existing plant steam systems can help produce electricity at more than twice efficiency of grid generated electricity. In this way, steam plant managers can realize substantial savings...

  2. Identifying Steam Opportunity "Impact" Inputs for the Steam System Assessment Tool (SSAT)

    E-Print Network [OSTI]

    Harrell, G.; Jendrucko, R.; Wright, A.

    2004-01-01T23:59:59.000Z

    IDENTIFYING STEAM OPPORTUNITY "IMPACT" INPUTS FOR THE STEAM SYSTEM ASSESSMENT TOOL (SSAT) Dr. Greg Harrell, University of Tennessee/Knoxville Dr. Richard Jendrucko, University of Tennessee/Knoxville Dr. Anthony Wright, Oak Ridge National...

  3. Mine roof geology information system

    SciTech Connect (OSTI)

    Peng, S.S.; Sasaoka, T.; Tang, D.X.; Wilson, Y.; Wilson, G.

    2005-05-01T23:59:59.000Z

    A project sponsored by the US Department of Energy under the Industry of Future (Mining) program was initiated five years ago. In this project a patented drill control unit (DCU) installed DIN. the J.H. Flecher & Co.'s roof bolter was used to record the drilling parameter for experiments conducted in the mines and laboratory. Today, the drilling parameters have been recorded for more than 1,000 roof bolt holes. This article summarizes the results to date including the methods for determining quantitatively the location of voids/fractures and estimation of roof rock strength from the recorded roof bolter drilling parameters. 8 figs., 2 tabs.

  4. Energy saving potential of various roof technologies

    E-Print Network [OSTI]

    Ray, Stephen D. (Stephen Douglas)

    2010-01-01T23:59:59.000Z

    Unconventional roof technologies such as cool roofs and green roofs have been shown to reduce building heating and cooling load. Although previous studies suggest potential for energy savings through such technologies, ...

  5. Roofs | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro Industries Pvt Ltd Jump to: navigation,MazeOhio:Ohio:RockwallRolling Hills|Romoland,Roofs Jump

  6. One Panel One Roof, DOE Powering Solar Workforce | Department...

    Broader source: Energy.gov (indexed) [DOE]

    One Panel One Roof, DOE Powering Solar Workforce One Panel One Roof, DOE Powering Solar Workforce...

  7. Solar Roof Cooling by Evaporation

    E-Print Network [OSTI]

    Patterson, G. V.

    1981-01-01T23:59:59.000Z

    It is generally recognized that as much as 60% of the air conditioning load in a building is generated by solar heat from the roof. This paper on SOLAR ROOF COOLING BY EVAPORATION is presented in slide form, tracing the history of 'nature's way...

  8. Measuring mine roof bolt strains

    DOE Patents [OSTI]

    Steblay, Bernard J. (Lakewood, CO)

    1986-01-01T23:59:59.000Z

    A mine roof bolt and a method of measuring the strain in mine roof bolts of this type are disclosed. According to the method, a flat portion on the head of the mine roof bolt is first machined. Next, a hole is drilled radially through the bolt at a predetermined distance from the bolt head. After installation of the mine roof bolt and loading, the strain of the mine roof bolt is measured by generating an ultrasonic pulse at the flat portion. The time of travel of the ultrasonic pulse reflected from the hole is measured. This time of travel is a function of the distance from the flat portion to the hole and increases as the bolt is loaded. Consequently, the time measurement is correlated to the strain in the bolt. Compensation for various factors affecting the travel time are also provided.

  9. Green roofs: potential at LANL

    SciTech Connect (OSTI)

    Pacheco, Elena M [Los Alamos National Laboratory

    2009-01-01T23:59:59.000Z

    Green roofs, roof systems that support vegetation, are rapidly becoming one of the most popular sustainable methods to combat urban environmental problems in North America. An extensive list of literature has been published in the past three decades recording the ecological benefits of green roofs; and now those benefits have been measured in enumerated data as a means to analyze the costs and returns of green roof technology. Most recently several studies have made substantial progress quantifying the monetary savings associated with storm water mitigation, the lessoning of the Urban Heat Island, and reduction of building cooling demands due to the implementation of green roof systems. Like any natural vegetation, a green roof is capable of absorbing the precipitation that falls on it. This capability has shown to significantly decrease the amount of storm water runoff produced by buildings as well as slow the rate at which runoff is dispensed. As a result of this reduction in volume and velocity, storm drains and sewage systems are relieved of any excess stress they might experience in a storm. For many municipalities and private building owners, any increase in storm water mitigation can result in major tax incentives and revenue that does not have to be spent on extra water treatments. Along with absorption of water, vegetation on green roofs is also capable of transpiration, the process by which moisture is evaporated into the air to cool ambient temperatures. This natural process aims to minimize the Urban Heat Island Effect, a phenomenon brought on by the dark and paved surfaces that increases air temperatures in urban cores. As the sun distributes solar radiation over a city's area, dark surfaces such as bitumen rooftops absorb solar rays and their heat. That heat is later released during the evening hours and the ambient temperatures do not cool as they normally would, creating an island of constant heat. Such excessively high temperatures induce heat strokes, heat exhaustion, and pollution that can agitate the respiratory system. The most significant savings associated with green roofs is in the reduction of cooling demands due to the green roof's thermal mass and their insulating properties. Unlike a conventional roof system, a green roof does not absorb solar radiation and transfer that heat into the interior of a building. Instead the vegetation acts as a shade barrier and stabilizes the roof temperature so that interior temperatures remain comfortable for the occupants. Consequently there is less of a demand for air conditioning, and thus less money spent on energy. At LANL the potential of green roof systems has already been realized with the construction of the accessible green roof on the Otowi building. To further explore the possibilities and prospective benefits of green roofs though, the initial capital costs must be invested. Three buildings, TA-03-1698, TA-03-0502, and TA-53-0031 have all been identified as sound candidates for a green roof retrofit project. It is recommended that LANL proceed with further analysis of these projects and implementation of the green roofs. Furthermore, it is recommended that an urban forestry program be initiated to provide supplemental support to the environmental goals of green roofs. The obstacles barring green roof construction are most often budgetary and structural concerns. Given proper resources, however, the engineers and design professionals at LANL would surely succeed in the proper implementation of green roof systems so as to optimize their ecological and monetary benefits for the entire organization.

  10. Roof control strategies for underground coal mines

    SciTech Connect (OSTI)

    Smith, W.C. (Bureau of Mines, Denver, CO (United States))

    1993-01-01T23:59:59.000Z

    Roof support, an important aspect of ground control, involves maintaining roof competency to ensure a safe and efficient mining environment. Wide variability in rock quality and stress distributions requires a systematic approach to roof support design that satisfies specific goals. The success of past roof support in reducing the incidence of roof falls has been primarily attributed to safer roof bolting practices. However, roof falls continue to be the number one occupational hazard in underground coal mines. This US Bureau of Mines report presents a general overview of roof bolting and other roof support methods used in the United States. Characteristics of bad roof and associated roof failure theories are briefly presented as background to roof support. Methods of detecting and monitoring roof behavior and/or bolt performance provide essential feedback on roof support requirements. A discussion follows on roof bolt design that assimilates roof and support parameters into useful equations or nomographs to help decide what bolt types to use and how they should be installed under different roof conditions. 35 refs., 8 figs.

  11. Sustainable roofs with real energy savings

    SciTech Connect (OSTI)

    Christian, J.E.; Petrie, T.W.

    1996-12-31T23:59:59.000Z

    This paper addresses the general concept of sustainability and relates it to the building owner`s selection of a low-slope roof. It offers a list of performance features of sustainable roofs. Experiences and data relevant to these features for four unique roofs are then presented which include: self-drying systems, low total equivalent warming foam insulation, roof coatings and green roofs. The paper concludes with a list of sustainable roofing features worth considering for a low-slope roof investment. Building owners and community developers are showing more interest in investing in sustainability. The potential exists to design, construct, and maintain roofs that last twice as long and reduce the building space heating and cooling energy loads resulting from the roof by 50% (based on the current predominant design of a 10-year life and a single layer of 1 to 2 in. (2.5 to 5.1 cm) of insulation). The opportunity to provide better low-slope roofs and sell more roof maintenance service is escalating. The general trend of outsourcing services could lead to roofing companies` owning the roofs they install while the traditional building owner owns the rest of the building. Such a situation would have a very desirable potential to internalize the costs of poor roof maintenance practices and high roof waste disposal costs, and to offer a profit for installing roofs that are more sustainable. 14 refs., 12 figs.

  12. Advanced Energy Efficient Roof System

    SciTech Connect (OSTI)

    Jane Davidson

    2008-09-30T23:59:59.000Z

    Energy consumption in buildings represents 40 percent of primary U.S. energy consumption, split almost equally between residential (22%) and commercial (18%) buildings.1 Space heating (31%) and cooling (12%) account for approximately 9 quadrillion Btu. Improvements in the building envelope can have a significant impact on reducing energy consumption. Thermal losses (or gains) from the roof make up 14 percent of the building component energy load. Infiltration through the building envelope, including the roof, accounts for an additional 28 percent of the heating loads and 16 percent of the cooling loads. These figures provide a strong incentive to develop and implement more energy efficient roof systems. The roof is perhaps the most challenging component of the building envelope to change for many reasons. The engineered roof truss, which has been around since 1956, is relatively low cost and is the industry standard. The roof has multiple functions. A typical wood frame home lasts a long time. Building codes vary across the country. Customer and trade acceptance of new building products and materials may impede market penetration. The energy savings of a new roof system must be balanced with other requirements such as first and life-cycle costs, durability, appearance, and ease of construction. Conventional residential roof construction utilizes closely spaced roof trusses supporting a layer of sheathing and roofing materials. Gypsum board is typically attached to the lower chord of the trusses forming the finished ceiling for the occupied space. Often in warmer climates, the HVAC system and ducts are placed in the unconditioned and otherwise unusable attic. High temperature differentials and leaky ducts result in thermal losses. Penetrations through the ceilings are notoriously difficult to seal and lead to moisture and air infiltration. These issues all contribute to greater energy use and have led builders to consider construction of a conditioned attic. The options considered to date are not ideal. One approach is to insulate between the trusses at the roof plane. The construction process is time consuming and costs more than conventional attic construction. Moreover, the problems of air infiltration and thermal bridges across the insulation remain. Another approach is to use structurally insulated panels (SIPs), but conventional SIPs are unlikely to be the ultimate solution because an additional underlying support structure is required except for short spans. In addition, wood spline and metal locking joints can result in thermal bridges and gaps in the foam. This study undertook a more innovative approach to roof construction. The goal was to design and evaluate a modular energy efficient panelized roof system with the following attributes: (1) a conditioned and clear attic space for HVAC equipment and additional finished area in the attic; (2) manufactured panels that provide structure, insulation, and accommodate a variety of roofing materials; (3) panels that require support only at the ends; (4) optimal energy performance by minimizing thermal bridging and air infiltration; (5) minimal risk of moisture problems; (6) minimum 50-year life; (7) applicable to a range of house styles, climates and conditions; (8) easy erection in the field; (9) the option to incorporate factory-installed solar systems into the panel; and (10) lowest possible cost. A nationwide market study shows there is a defined market opportunity for such a panelized roof system with production and semi-custom builders in the United States. Senior personnel at top builders expressed interest in the performance attributes and indicate long-term opportunity exists if the system can deliver a clear value proposition. Specifically, builders are interested in (1) reducing construction cycle time (cost) and (2) offering increased energy efficiency to the homebuyer. Additional living space under the roof panels is another low-cost asset identified as part of the study. The market potential is enhanced through construction activity levels in target marke

  13. Cool Roofs: Your Questions Answered

    Broader source: Energy.gov [DOE]

    When Secretary Chu announced that the Department of Energy had installed a “cool roof” atop the west building of our Washington, DC headquarters, it elicited a fair number of questions from his Facebook fans. We decided to reach out to the people behind the project for their insight on the specific benefits of switching to a cool roof, and the process that went into making that choice.

  14. Green Roof Media Selection forGreen Roof Media Selection for the Minimization of Pollutantthe Minimization of Pollutant

    E-Print Network [OSTI]

    Clark, Shirley E.

    1 Green Roof Media Selection forGreen Roof Media Selection for the Minimization of Pollutantthe Minimization of Pollutant Loadings in Roof RunoffLoadings in Roof Runoff Brett LongBrett Long Shirley Clark for Green Roof Research Green Roofs:Green Roofs: The New BMP (at least in the US)The New BMP (at least

  15. Roof screening for underground coal mines: recent developments

    SciTech Connect (OSTI)

    Compton, C.S.; Gallagher, S.; Molinda, G.M.; Mark, C.; Wilson, G.

    2008-06-15T23:59:59.000Z

    The use of screens to control falls of the immediate roof or roof skin (that is between the installed primary and secondary roof supports) is described. 5 figs.

  16. SSST Module Slide 1: Hello, and welcome to this introduction on the Steam System Tool Suite.

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    ) that supports ITP's mission to improve the energy intensity of the U.S. industrial sector through a coordinated steam system pertaining to energy consumption, fuel type, unit costs, maintenance and energy monitoring training, publications, and software tools. Let's get started to show how to begin to develop a list

  17. Solare Cell Roof Tile And Method Of Forming Same

    DOE Patents [OSTI]

    Hanoka, Jack I. (Brookline, MA); Real, Markus (Oberberg, CH)

    1999-11-16T23:59:59.000Z

    A solar cell roof tile includes a front support layer, a transparent encapsulant layer, a plurality of interconnected solar cells and a backskin layer. The front support layer is formed of light transmitting material and has first and second surfaces. The transparent encapsulant layer is disposed adjacent the second surface of the front support layer. The interconnected solar cells has a first surface disposed adjacent the transparent encapsulant layer. The backskin layer has a first surface disposed adjacent a second surface of the interconnected solar cells, wherein a portion of the backskin layer wraps around and contacts the first surface of the front support layer to form the border region. A portion of the border region has an extended width. The solar cell roof tile may have stand-offs disposed on the extended width border region for providing vertical spacing with respect to an adjacent solar cell roof tile.

  18. EVALUATION OF ROOF BOLTING REQUIREMENTS BASED ON IN-MINE ROOF BOLTER DRILLING

    SciTech Connect (OSTI)

    Syd S. Peng

    2003-04-15T23:59:59.000Z

    Roof bolting is the most popular method for underground openings in the mining industry, especially in the bedded deposits such as coal, potash, salt etc. In fact, all U.S. underground coal mine entries are roof-bolted as required by law. However, roof falls still occur frequently in the roof bolted entries. The two possible reasons are: the lack of knowledge of and technology to detect the roof geological conditions in advance of mining, and lack of roof bolting design criteria for modern roof bolting systems. This research is to develop a method for predicting the roof geology and stability condition in real time during roof bolting operation. Based on such information, roof bolting design criteria for modern roof bolting systems will be developed for implementation in real time. More field tests have been performed. A trendline analysis method has been developed. This method would improve the accuracy in detecting the locations of fractures and in determining the rock strength.

  19. EVALUATION OF ROOF BOLTING REQUIREMENTS BASED ON IN-MINE ROOF BOLTER DRILLING

    SciTech Connect (OSTI)

    Syd S. Peng

    2002-10-15T23:59:59.000Z

    Roof bolting is the most popular method for underground openings in the mining industry, especially in the bedded deposits such as coal, potash, salt etc. In fact, all U.S. underground coal mine entries are roof-bolted as required by law. However, roof falls still occur frequently in the roof bolted entries. The two possible reasons are: the lack of knowledge of and technology to detect the roof geological conditions in advance of mining, and lack of roof bolting design criteria for modern roof bolting systems. This research is to develop a method for predicting the roof geology and stability condition in real time during roof bolting operation. Based on such information, roof bolting design criteria for modern roof bolting systems will be developed for implementation in real time. Additional field tests have been performed in this quarter. The development of the data interpretation methodology and other related tasks are still continuing.

  20. EVALUATION OF ROOF BOLTING REQUIREMENTS BASED ON IN-MINE ROOF BOLTER DRILLING

    SciTech Connect (OSTI)

    Syd S. Peng

    2003-01-15T23:59:59.000Z

    Roof bolting is the most popular method for underground openings in the mining industry, especially in the bedded deposits such as coal, potash, salt etc. In fact, all U.S. underground coal mine entries are roof-bolted as required by law. However, roof falls still occur frequently in the roof bolted entries. The two possible reasons are: the lack of knowledge of and technology to detect the roof geological conditions in advance of mining, and lack of roof bolting design criteria for modern roof bolting systems. This research is to develop a method for predicting the roof geology and stability condition in real time during roof bolting operation. Based on such information, roof bolting design criteria for modern roof bolting systems will be developed for implementation in real time. Additional field tests have been performed. It is found that the drilling power can be used as a supplementary method for detecting voids/fractures and rock interfaces.

  1. Effects of solar photovoltaic panels on roof heat transfer

    E-Print Network [OSTI]

    Dominguez, Anthony; Kleissl, Jan; Luvall, Jeffrey C

    2011-01-01T23:59:59.000Z

    performance of  photovoltaic roofs, ASHRAE Trans 107 (absorption of solar radiation.   roof cooling load [Wm ] a) exposed roof PV covered roof b) GHI [W m ] Time [PST

  2. Permeable Pavements, Green Roofs, and Cisterns

    E-Print Network [OSTI]

    Hunt, William F.

    Permeable Pavements, Green Roofs, and Cisterns Stormwater Treatment Practices for Low site planning and engineer- pavements, green roofs, and cisterns, are ing to reduce or prevent cooperating. #12;Permeable Pavements What are they? Permeable pavements provide alternatives to standard

  3. STATE OF CALIFORNIA ENVELOPE INSULATION; ROOFING; FENESTRATION

    E-Print Network [OSTI]

    STATE OF CALIFORNIA ENVELOPE ­ INSULATION; ROOFING; FENESTRATION CEC-CF-6R-ENV-01 (Revised 08/09) CALIFORNIA ENERGY COMMISSION INSTALLATION CERTIFICATE CF-6R-ENV-01 Envelope ­ Insulation; Roofing:__________________________________ Brand Name:_______________________________ Thickness (inches):_________________________ Thermal

  4. IDENTIFYING ROOF FALL PREDICTORS USING FUZZY CLASSIFICATION

    SciTech Connect (OSTI)

    Bertoncini, C. A.; Hinders, M. K. [NDE Lab, College of William and Mary, Williamsburg, VA, 23187-8795 (United States)

    2010-02-22T23:59:59.000Z

    Microseismic monitoring involves placing geophones on the rock surfaces of a mine to record seismic activity. Classification of microseismic mine data can be used to predict seismic events in a mine to mitigate mining hazards, such as roof falls, where properly bolting and bracing the roof is often an insufficient method of preventing weak roofs from destabilizing. In this study, six months of recorded acoustic waveforms from microseismic monitoring in a Pennsylvania limestone mine were analyzed using classification techniques to predict roof falls. Fuzzy classification using features selected for computational ease was applied on the mine data. Both large roof fall events could be predicted using a Roof Fall Index (RFI) metric calculated from the results of the fuzzy classification. RFI was successfully used to resolve the two significant roof fall events and predicted both events by at least 15 hours before visual signs of the roof falls were evident.

  5. Weathering of Roofing Materials-An Overview

    E-Print Network [OSTI]

    Berdahl, Paul; Akbari, Hashem; Levinson, Ronnen; Miller, William A.

    2008-01-01T23:59:59.000Z

    by oxidation. b) Wind Wind exerts forces on roofing. Tallermore force. Since the kinetic energy of wind and the

  6. SOLAR ROOF POWERS THE NJIT CAMPUS CENTER

    E-Print Network [OSTI]

    Bieber, Michael

    SOLAR ROOF POWERS THE NJIT CAMPUS CENTER THE SKY'S THE LIMIT: BERNADETTE MOKE SITS ON THE ROOF, ARE 160 SOLAR PANELS, SOME OF WHICH AUTOMATICALLY FOLLOW THE PATH OF THE SUN. 10 NJITMAGAZINE COVER STORY'S THE LIMIT: SOLAR ROOF POWERS THE NJIT CAMPUS CENTER "The solar panels even move a little at night," says

  7. ROOFING PROJECT ODORS How Can EHS Help?

    E-Print Network [OSTI]

    Stephens, Graeme L.

    ROOFING PROJECT ODORS How Can EHS Help? We can work with occupants to act as a liaison with Facili- ties Management and the contractor to identify ways to reduce odors. Contact us at 491­ 6745. Roof work is a necessary part of building preservation. Roofing odors are generated during these projects when hot asphalt

  8. Generalized Roof Duality Fredrik Kahl, Petter Strandmark

    E-Print Network [OSTI]

    Lunds Universitet

    Generalized Roof Duality Fredrik Kahl, Petter Strandmark Centre for Mathematical Sciences Lund University, Sweden Abstract The roof dual bound for quadratic unconstrained binary optimization is the basis by introducing auxiliary variables and then apply the quadratic roof dual bound, but this may lead to loose

  9. Fall Protection for Roof Workers Before working on roofs above 7 feet,1 Physical Plant staff should implement an

    E-Print Network [OSTI]

    de Lijser, Peter

    Fall Protection for Roof Workers Before working on roofs above 7 ½ feet,1 Physical Plant staff practical fall protection method. Most roofs at CSUF qualify as monolithic roofing systems. It may involve a single layer of sealed rubber. Multiple unit roofing systems utilize shingles or tiles. The two roofing

  10. Evaluation of Roof Bolting Requirements Based on In-Mine Roof Bolter Drilling

    SciTech Connect (OSTI)

    Syd S. Peng

    2005-10-01T23:59:59.000Z

    Roof bolting is the most popular method for underground openings in the mining industry, especially in the bedded deposits such as coal. In fact, all U.S. underground coal mine entries are roof-bolted as required by law. However, roof falls still occur frequently in the roof bolted entries. The two possible reasons are: the lack of knowledge of and technology to detect the roof geological conditions in advance of mining, and lack of roof bolting design criteria for modern roof bolting systems. This research is to develop a method for predicting the roof geology and stability condition in real time during roof bolting operation. Based on this information, roof bolting design criteria for modern roof bolting systems will be developed for implementation in real time. For the prediction of roof geology and stability condition in real time, a micro processor was used and a program developed to monitor and record the drilling parameters of roof bolter. These parameters include feed pressure, feed flow (penetration rate), rotation pressure, rotation rate, vacuum pressure, oil temperature of hydraulic circuit, and signals for controlling machine. From the results of a series of laboratory and underground tests so far, feed pressure is found to be a good indicator for identifying the voids/fractures and estimating the roof rock strength. The method for determining quantitatively the location and the size of void/fracture and estimating the roof rock strength from the drilling parameters of roof bolter was developed. Also, a set of computational rules has been developed for in-mine roof using measured roof drilling parameters and implemented in MRGIS (Mine Roof Geology Information System), a software package developed to allow mine engineers to make use of the large amount of roof drilling parameters for predicting roof geology properties automatically. For the development of roof bolting criteria, finite element models were developed for tensioned and fully grouted bolting designs. Numerical simulations were performed to investigate the mechanisms of modern roof bolting systems including both the tension and fully grouted bolts. Parameters to be studied are: bolt length, bolt spacing, bolt size/strength, grout annulus, in-situ stress condition, overburden depth, and roof geology (massive strata, fractured, and laminated or thinly-bedded). Based on the analysis of the mechanisms of both bolting systems and failure modes of the bolted strata, roof bolting design criteria and programs for modern roof bolting systems were developed. These criterion and/or programs were combined with the MRGIS for use in conjunction with roof bolt installation.

  11. Improving Steam System Performance: A Sourcebook for Industry, Second Edition (Book) (Revised)

    SciTech Connect (OSTI)

    Not Available

    2012-10-01T23:59:59.000Z

    Improving Steam System Performance: A Sourcebook for Industry was developed for the U.S. Department of Energy's (DOE) Advanced Manufacturing Office (AMO), formerly the Industrial Technologies Program. AMO undertook this project as a series of sourcebook publications. Other topics in this series include: compressed air systems, pumping systems, fan systems, process heating and motor and drive systems. For more information about program resources, see AMO in the Where to Find Help section of this publication.

  12. Self drying roofs: What! No dripping!

    SciTech Connect (OSTI)

    Desjarlais, A.

    1995-12-31T23:59:59.000Z

    Many roofs are replaced because water accumulates in portions of the roofing system.These accumulations can cause dripping, accelerated membrane failure, poor thermal performance, the threat of structural decay, and the depreciation of building assets. Traditionally, the roofing industry has been concerned with controlling the inflow of water into the roof. An example of this strategy would be the development of a more reliable membrane. However, roof membranes inevitably leak. For this reason, the roof design strategy of the future must be concerned with controlling water outflow. The requirements of this type of roof system are described. Under normal operating conditions (no leaks), the total moisture content of a self-drying roof system shall not increase with time and condensation shall not occur under the membrane during winter uptake. Moisture vapor movement by convection must be eliminated and the flow of water by gravity through imperfections in the roof system must be controlled. After a leak has occurred, no condensation on the upper surface of the deck shall be tolerated and the water introduced by the leak must be dissipated to the building interior in a minimum amount of time. Finite difference computer modeling is used to demonstrate the effectiveness of the design. The impact of deck and insulation permeance, climate, leaks, and wintertime water uptake are simulated. A database of simulations is qualitatively described; this database will be used in future work to produce a simplified means of assessing the design parameters of a self-drying roof system.

  13. EVALUATION OF ROOF BOLTING REQUIREMENTS BASED ON IN-MINE ROOF BOLTER DRILLING

    SciTech Connect (OSTI)

    Syd S. Peng

    2001-10-15T23:59:59.000Z

    Roof bolting is the most popular method for underground openings in the mining industry, especially in the bedded deposits such as coal, potash, salt etc. In fact, all U.S. underground coal mine entries are roof-bolted as required by law. However, roof falls still occur frequently in the roof bolted entries. The two possible reasons are: the lack of knowledge of and technology to detect the roof geological conditions in advance of mining, and lack of roof bolting design criteria for modern roof bolting systems. This research is to develop a method for predicting the roof geology and stability condition in real time during roof bolting operation. Based on such information, roof bolting design criteria for modern roof bolting systems will be developed for implementation in real time. The retrofitting works for a dedicated roof bolter for this research has been completed. The laboratory tests performed using this machine on simulated roof blocks have been conducted. The analysis performed on the testing data showed promising signs to detect the rock interface, fractures, as well as the rock types. The other tasks were progressing as planned.

  14. EVALUATION OF ROOF BOLTING REQUIREMENTS BASED ON IN-MINE ROOF BOLTER DRILLING

    SciTech Connect (OSTI)

    Syd S. Peng

    2001-07-15T23:59:59.000Z

    Roof bolting is the most popular method for underground openings in the mining industry, especially in the bedded deposits such as coal, potash, salt etc. In fact, all U.S. underground coal mine entries are roof-bolted as required by law. However, roof falls still occur frequently in the roof bolted entries. The two possible reasons are: the lack of knowledge of and technology to detect the roof geological conditions in advance of mining, and lack of roof bolting design criteria for modern roof bolting systems. This research is to develop a method for predicting the roof geology and stability condition in real time during roof bolting operation. Based on such information, roof bolting design criteria for modern roof bolting systems will be developed for implementation in real time. In this quarter, retrofitting work to build a dedicated roof bolter for this research has been started. A number of numerical methods have been developed to improve the quality of and to analyze the collected drilling parameters. Finite element modeling of roof bolting mechanism is continuing.

  15. Green Roof Effect on Arthropod Biodiversity By Caitlin Race

    E-Print Network [OSTI]

    Ginzel, Matthew

    Green Roof Effect on Arthropod Biodiversity By Caitlin Race A green roof is a roof. Green roof technology has become increasingly popular due to several benefits including, insulation, runoff protection, and aesthetic value. This project was designed to see if a green roof would benefit

  16. Thermal performance measurements of insulated roof systems

    SciTech Connect (OSTI)

    Courville, G.E.; Childs, K.W.; Walukas, D.J.; Childs, P.W.; Griggs, E.I.

    1985-01-01T23:59:59.000Z

    Oak Ridge National Laboratory has established a Roof Thermal Researcch Apparatus for carrying out thermal and hygric experiments on sections of low-sloped roofs. Test panels are exposed to a controlled temperature interior space and to the prevailing East Tennessee exterior environment. They are well instrumented and all data are stored and aided in the analysis by computer systems. Current experiments include studies of the effect of wet insulation on membrane temperature, thermal storage phenomena in built-up roof insulation, and the effects of varying surface reflectance on roof thermal performance.

  17. EVALUATION OF ROOF BOLTING REQUIREMENTS BASED ON IN-MINE ROOF BOLTER DRILLING

    SciTech Connect (OSTI)

    Syd S. Peng

    2003-07-15T23:59:59.000Z

    Roof bolting is the most popular method for underground openings in the mining industry, especially in the bedded deposits such as coal, potash, salt etc. In fact, all U.S. underground coal mine entries are roof-bolted as required by law. However, roof falls still occur frequently in the roof bolted entries. The two possible reasons are: the lack of knowledge of and technology to detect the roof geological conditions in advance of mining, and lack of roof bolting design criteria for modern roof bolting systems. This research is to develop a method for predicting the roof geology and stability condition in real time during roof bolting operation. Based on such information, roof bolting design criteria for modern roof bolting systems will be developed for implementation in real time. In this quarter, the field, theoretical and programming works have been performed toward achieving the research goals set in the proposal. The selected site and the field testing plan enabled us to test all three aspects of roof geological features. The development of the data interpretation methodologies and the geology mapping computer program have also been preceding well.

  18. Evolution of cool-roof standards in the United States

    E-Print Network [OSTI]

    Akbari, Hashem

    2008-01-01T23:59:59.000Z

    for steep-sloped nonresidential roofs in Title 24. Online atof SSP90.1 for Reflective Roofs. ASHRAE Transactions, 104(pp. 984-995. Evolution of cool roof standards in the United

  19. Status of cool roof standards in the United States

    E-Print Network [OSTI]

    Akbari, Hashem; Levinson, Ronnen

    2008-01-01T23:59:59.000Z

    requirements for residential roofs in Title 24. Online atAkbari, H. 1998. Cool roofs save energy. ASHRAE Transactionsfor steep-sloped nonresidential roofs in Title 24. Online at

  20. Condensation Risk of Mechanically Attached Roof Systems in Cold Climate Zones

    SciTech Connect (OSTI)

    Pallin, Simon B [ORNL

    2013-01-01T23:59:59.000Z

    A white roof, cool roof, is constructed to decrease thermal loads from solar radiation, therefore saving energy by decreasing the cooling demands. Unfortunately, cool roofs with mechanically attached membrane, have shown to have a higher risk of intermediate condensation in the materials below the membrane in certain climates (Ennis & Kehrer, 2011) and in comparisons with similar construction with a darker exterior surface (Bludau, Zirkelbach, & Kuenzel, 2009). As a consequence, questions have been raised regarding the sustainability and reliability of using cool roof membranes in Northern U.S. climate zones. A white roof surface reflects more of the incident solar radiation in comparisons with a dark surface, which makes a distinguished difference on the surface temperature of the roof. However, flat roofs with either a light or dark surface and if facing a clear sky, are constantly losing energy to the sky due to the exchange of infrared radiation. This phenomenon exists both during the night and the day. During the day, if the sun shines on the roof surface, the exchange of infrared radiation typically becomes insignificant. During nights and in cold climates, the temperature difference between the roof surface and the sky can deviate up to 20 C (Hagentoft, 2001) which could result in a very cold surface temperature compared to the ambient temperature. Further, a colder surface temperature of the roof increases the energy loss and the risk of condensation in the building materials below the membrane. In conclusion, both light and dark coated roof membranes are cooled by the infrared radiation exchange during the night, though a darker membrane is more heated by the solar radiation during the day, thus decreasing the risk of condensation. The phenomenon of night time cooling from the sky and the lack of solar gains during the day is not likely the exclusive problem concerning the risk of condensation in cool roofs with mechanically attached membranes. Roof systems with thermoplastic membranes are prone to be more effected by interior air intrusion into the roof construction; both due to the wind induced pressure differences and due to the flexibility and elasticity of the membrane (Molleti, Baskaran, Kalinger, & Beaulieu, 2011). Depending on the air permeability of the material underneath the membrane, wind forces increase the risk of fluttering (also referred as billowing) of the thermoplastic membrane. Expectably, the wind induced pressure differences creates a convective air flow into the construction i.e. Page 2 air intrusion. If the conditions are right, moisture from the exchanging air may condensate on surfaces with a temperature below dew-point. The definite path of convective airflows through the building envelope is usually very difficult to determine and therefore simplified models (K nzel, Zirkelbach, & Scfafaczek, 2011) help to estimate an additional moisture loads as a result of the air intrusion. The wind uplifting pressure in combination with wind gusts are important factors for a fluttering roof. Unfortunately, the effect from a fluctuating wind is difficult to estimate as this is a highly dynamic phenomenon and existing standards (ASTM, 2011a) only take into account a steady state approach i.e. there is no guidance or regulations on how to estimate the air intrusion rate. Obviously, a more detailed knowledge on the hygrothermal performance of mechanically attached cool roof system is requested; in consideration to varying surface colors, roof air tightness, climate zones and indoor moisture supply.

  1. Steam System Balancing and Tuning for Multifamily Residential Buildings in Chicagoland - Second Year of Data Collection

    SciTech Connect (OSTI)

    Choi, J.; Ludwig, P.; Brand, L.

    2013-08-01T23:59:59.000Z

    Steam heated buildings often suffer from uneven heating as a result of poor control of the amount of steam entering each radiator. In order to satisfy the heating load to the coldest units, other units are overheated. As a result, some tenants complain of being too hot and open their windows in the middle of winter, while others complain of being too cold and are compelled to use supplemental heat sources. Building on previous research, CNT Energy identified 10 test buildings in Chicago and conducted a study to identify best practices for the methodology, typical costs, and energy savings associated with steam system balancing. A package of common steam balancing measures was assembled and data were collected on the buildings before and after these retrofits were installed to investigate the process, challenges, and the cost effectiveness of improving steam systems through improved venting and control systems. The test buildings that received venting upgrades and new control systems showed 10.2% savings on their natural gas heating load, with a simple payback of 5.1 years. The methodologies for and findings from this study are presented in detail in this report. This report has been updated from a version published in August 2012 to include natural gas usage information from the 2012 heating season and updated natural gas savings calculations.

  2. Steam systems in industry: Energy use and energy efficiency improvement potentials

    SciTech Connect (OSTI)

    Einstein, Dan; Worrell, Ernst; Khrushch, Marta

    2001-07-22T23:59:59.000Z

    Steam systems are a part of almost every major industrial process today. Thirty-seven percent of the fossil fuel burned in US industry is burned to produce steam. In this paper we will establish baseline energy consumption for steam systems. Based on a detailed analysis of boiler energy use we estimate current energy use in boilers in U.S. industry at 6.1 Quads (6.4 EJ), emitting almost 66 MtC in CO{sub 2} emissions. We will discuss fuels used and boiler size distribution. We also describe potential savings measures, and estimate the economic energy savings potential in U.S. industry (i.e. having payback period of 3 years or less). We estimate the nationwide economic potential, based on the evaluation of 16 individual measures in steam generation and distribution. The analysis excludes the efficient use of steam and increased heat recovery. Based on the analysis we estimate the economic potential at 18-20% of total boiler energy use, resulting in energy savings approximately 1120-1190 TBtu ( 1180-1260 PJ). This results in a reduction of CO{sub 2} emissions equivalent to 12-13 MtC.

  3. Accelerated Aging of Roofing Surfaces

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: The Future of1 AAccelerated aging of roofing surfaces Hugo Destaillats, Ph.D.

  4. Thermal Performance of Vegetative Roofing Systems

    SciTech Connect (OSTI)

    Desjarlais, Andre Omer [ORNL; Zaltash, Abdolreza [ORNL; Atchley, Jerald Allen [ORNL; Ennis, Mike J [ORNL

    2010-01-01T23:59:59.000Z

    Vegetative roofing, otherwise known as green or garden roofing, has seen tremendous growth in the last decade in the United States. The numerous benefits that green roofs provide have helped to fuel their resurgence in industrial and urban settings. There are many environmental and economical benefits that can be realized by incorporating a vegetative roof into the design of a building. These include storm-water retention, energy conservation, reduction in the urban heat island effect, increased longevity of the roofing membrane, the ability of plants to create biodiversity and filter air contaminants, and beautification of the surroundings by incorporating green space. The vegetative roof research project at Oak Ridge National Laboratory (ORNL) was initiated to quantify the thermal performance of various vegetative roofing systems relative to black and white roofs. Single Ply Roofing Institute (SPRI) continued its long-term commitment to cooperative research with ORNL in this project. Low-slope roof systems for this study were constructed and instrumented for continuous monitoring in the mixed climate of East Tennessee. This report summarizes the results of the annual cooling and heating loads per unit area of three vegetative roofing systems with side-by-side comparison to black and white roofing systems as well as a test section with just the growing media without plants. Results showed vegetative roofs reduced heat gain (reduced cooling loads) compared to the white control system due to the thermal mass, extra insulation, and evapo-transpiration associated with the vegetative roofing systems. The 4-inch and tray systems reduced the heat gain by approximately 61%, while the reduction with the 8-inch vegetative roof was found to be approximately 67%. The vegetative roofing systems were more effective in reducing heat gain than in reducing heat losses (heating loads). The reduction in heat losses for the 4-inch and tray systems were found to be approximately 40% in the mixed climate of East Tennessee. It should be noted that these values are climate dependent. Vegetative roofs also reduced the temperature (heat exposure) and temperature fluctuations (thermal stress) experienced by the membrane. In the cooling season of East Tennessee, the average peak temperature of the 4-inch and tray systems was found to be approximately 94 F cooler than the control black roofing system. The average temperature fluctuations at the membrane for the 4-inch and tray systems were found to be approximately 10 F compared to 125 F for black and 64 F for white systems. As expected, the 8-inch vegetative roof had the lowest fluctuations at approximately 2 F. Future work will include modeling of the energy performance of vegetative roof panels in the test climate of East Tennessee. The validated model then will be used to predict energy use in roofs with different insulation levels and in climates different from the test climate.

  5. affect green roof: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Early green roof cooling and energy reduction research in North America took place in Canada and the northern latitudes of the United States, where green roofs reduced rooftop...

  6. Effects of solar photovoltaic panels on roof heat transfer

    E-Print Network [OSTI]

    Dominguez, Anthony; Kleissl, Jan; Luvall, Jeffrey C

    2011-01-01T23:59:59.000Z

    the energy performance of  photovoltaic roofs, ASHRAE Trans A thermal model for photovoltaic systems, Solar Energy, Effects of Solar Photovoltaic Panels on Roof Heat Transfer 

  7. EVALUATION OF ROOF BOLTING REQUIREMENTS BASED ON IN-MINE ROOF BOLTER DRILLING

    SciTech Connect (OSTI)

    Syd S. Peng

    2002-01-15T23:59:59.000Z

    Roof bolting is the most popular method for underground openings in the mining industry, especially in the bedded deposits such as coal, potash, salt etc. In fact, all U.S. underground coal mine entries are roof-bolted as required by law. However, roof falls still occur frequently in the roof bolted entries. The two possible reasons are: the lack of knowledge of and technology to detect the roof geological conditions in advance of mining, and lack of roof bolting design criteria for modern roof bolting systems. This research is to develop a method for predicting the roof geology and stability condition in real time during roof bolting operation. Based on such information, roof bolting design criteria for modern roof bolting systems will be developed for implementation in real time. A new mechanical approach to estimate rock strengths using the acquired drilling parameters has been proposed. This approach takes a number of important factors, that have never been studied in the previous researches, into the considerations. Good results have been shown using the new approach on the testing data.

  8. EVALUATION OF ROOF BOLTING REQUIREMENTS BASED ON IN-MINE ROOF BOLTER DRILLING

    SciTech Connect (OSTI)

    Syd S. Peng

    2002-04-15T23:59:59.000Z

    Roof bolting is the most popular method for underground openings in the mining industry, especially in the bedded deposits such as coal, potash, salt etc. In fact, all U.S. underground coal mine entries are roof-bolted as required by law. However, roof falls still occur frequently in the roof bolted entries. The two possible reasons are: the lack of knowledge of and technology to detect the roof geological conditions in advance of mining, and lack of roof bolting design criteria for modern roof bolting systems. This research is to develop a method for predicting the roof geology and stability condition in real time during roof bolting operation. Based on such information, roof bolting design criteria for modern roof bolting systems will be developed for implementation in real time. More laboratory tests have been performed in this quarter. The analysis performed on the testing data showed: (1) abnormal rotational accelerations can be used as the indicator of the rock interfaces, and (2) the sharp drops of drilling thrust and torque agree well with the locations of fractures.

  9. Lightweight, self-ballasting photovoltaic roofing assembly

    DOE Patents [OSTI]

    Dinwoodie, Thomas L.

    2006-02-28T23:59:59.000Z

    A photovoltaic roofing assembly comprises a roofing membrane (102), a plurality of photovoltaic modules (104, 106, 108) disposed as a layer on top of the roofing membrane (102), and a plurality of pre-formed spacers, pedestals or supports (112, 114, 116, 118, 120, 122) which are respectively disposed below the plurality of photovoltaic modules (104, 106, 108) and integral therewith, or fixed thereto. Spacers (112, 114, 116, 118, 120, 122) are disposed on top of roofing membrane (102). Membrane (102) is supported on conventional roof framing, and attached thereto by conventional methods. In an alternative embodiment, the roofing assembly may have insulation block (322) below the spacers (314, 314', 315, 315'). The geometry of the pre-formed spacers (112, 114, 116, 118, 120, 122, 314, 314', 315, 315') is such that wind tunnel testing has shown its maximum effectiveness in reducing net forces of wind uplift on the overall assembly. Such construction results in a simple, lightweight, self-ballasting, readily assembled roofing assembly which resists the forces of wind uplift using no roofing penetrations.

  10. Lightweight, self-ballasting photovoltaic roofing assembly

    DOE Patents [OSTI]

    Dinwoodie, Thomas L. (Berkeley, CA)

    1998-01-01T23:59:59.000Z

    A photovoltaic roofing assembly comprises a roofing membrane (102), a plurality of photovoltaic modules (104, 106, 108) disposed as a layer on top of the roofing membrane (102), and a plurality of pre-formed spacers, pedestals or supports (112, 114, 116, 118, 120, 122) which are respectively disposed below the plurality of photovoltaic modules (104, 106, 108) and integral therewith, or fixed thereto. Spacers (112, 114, 116, 118, 120, 122) are disposed on top of roofing membrane (102). Membrane (102) is supported on conventional roof framing, and attached thereto by conventional methods. In an alternative embodiment, the roofing assembly may have insulation block (322) below the spacers (314, 314', 315, 315'). The geometry of the preformed spacers (112, 114, 116, 118, 120, 122, 314, 314', 315, 315') is such that wind tunnel testing has shown its maximum effectiveness in reducing net forces of wind uplift on the overall assembly. Such construction results in a simple, lightweight, self-ballasting, readily assembled roofing assembly which resists the forces of wind uplift using no roofing penetrations.

  11. Lightweight, self-ballasting photovoltaic roofing assembly

    DOE Patents [OSTI]

    Dinwoodie, T.L.

    1998-05-05T23:59:59.000Z

    A photovoltaic roofing assembly comprises a roofing membrane (102), a plurality of photovoltaic modules (104, 106, 108) disposed as a layer on top of the roofing membrane (102), and a plurality of pre-formed spacers, pedestals or supports (112, 114, 116, 118, 120, 122) which are respectively disposed below the plurality of photovoltaic modules (104, 106, 108) and integral therewith, or fixed thereto. Spacers (112, 114, 116, 118, 120, 122) are disposed on top of roofing membrane (102). Membrane (102) is supported on conventional roof framing, and attached thereto by conventional methods. In an alternative embodiment, the roofing assembly may have insulation block (322) below the spacers (314, 314', 315, 315'). The geometry of the preformed spacers (112, 114, 116, 118, 120, 122, 314, 314', 315, 315') is such that wind tunnel testing has shown its maximum effectiveness in reducing net forces of wind uplift on the overall assembly. Such construction results in a simple, lightweight, self-ballasting, readily assembled roofing assembly which resists the forces of wind uplift using no roofing penetrations.

  12. Decision guide for roof slope selection

    SciTech Connect (OSTI)

    Sharp, T.R.; Wendt, R.L.; McCorkle, J.E.

    1988-10-01T23:59:59.000Z

    This decision guide has been written for personnel who are responsible for the design, construction, and replacement of Air Force roofs. It provides the necessary information and analytical tools for making prudent and cost-effective decisions regarding the amount of slope to provide in various roofing situations. Because the expertise and experience of the decision makers will vary, the guide contains both basic slope-related concepts as well as more sophisticated technical data. This breadth of information enables the less experienced user to develop an understanding of roof slope issues before applying the more sophisticated analytical tools, while the experienced user can proceed directly to the technical sections. Although much of this guide is devoted to the analysis of costs, it is not a cost-estimating document. It does, however, provide the reader with the relative costs of a variety of roof slope options; and it shows how to determine the relative cost-effectiveness of different options. The selection of the proper roof slope coupled with good roof design, a quality installation, periodic inspection, and appropriate maintenance and repair will achieve the Air Force's objective of obtaining the best possible roofing value for its buildings. 21 refs., 17 figs., 10 tabs.

  13. ROOF CHARACTERISATION RELATED TO FIRE PROPAGATION RISK BY A NUMERICAL

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    ROOF CHARACTERISATION RELATED TO FIRE PROPAGATION RISK BY A NUMERICAL APPROACH L. Fournier1 , A by thé roof: - one is thé use of intumescent strips on thé roof, - thé other consists of extending thé fire walls (typically 70 cm or 1 m) above thé roof levé1 in order to prevent thé flame from being blown

  14. RIS-M-2471 RUN-OFF FROM ROOFS

    E-Print Network [OSTI]

    RISØ-M-2471 RUN-OFF FROM ROOFS Jørn Roed Abstract. In order to find the run-off from roof material a roof has been constructed with two different slopes (30° and 45°). Beryllium-7 and caesium-137 has been used as tracers. Considering new roof material the pollution removed by runoff processes has been shown

  15. Design considerations for retractable-roof stadia

    E-Print Network [OSTI]

    Frazer, Andrew H., 1981-

    2005-01-01T23:59:59.000Z

    As existing open-air or fully enclosed stadia are reaching their life expectancies, cities are choosing to replace them with structures with moving roofs. This kind of facility provides protection from weather for spectators, ...

  16. Roof Coating Procedures and Their Productivity Gains 

    E-Print Network [OSTI]

    Bonaby, J.; Schaub, D.

    2006-01-01T23:59:59.000Z

    Roof Coating Procedures and their Productivity Gains John Bonaby and Dr. Diane Schaub, University of Florida As building envelope improvements are realized in organizations as ways to insulate businesses from high energy costs, the relative... benefit of the installation of different roof coating technologies and comparable application procedures of these technologies are ambiguous. The focal point of this research is to determine the effective correlation between various commercially...

  17. Re-roofing slashes chain's cooling costs

    SciTech Connect (OSTI)

    Barber, J.

    1984-03-26T23:59:59.000Z

    A re-roofing program to install single-ply synthetic rubber coated with hypalon, a white synthetic rubber, will save each Hardee restaurant an average of $25,000 over a 10-year period. The savings will come from reduced air conditioning costs, which will vary by location. The new roof system tolerates temperatures from -40 to over 150/sup 0/F. Reflection from the white surface makes the material more energy efficient than conventional hot asphalt.

  18. Next Generation Roofs and Attics for Homes

    SciTech Connect (OSTI)

    Miller, William A [ORNL] [ORNL; Kosny, Jan [ORNL] [ORNL

    2008-01-01T23:59:59.000Z

    Prototype residential roof and attic assemblies were constructed and field tested in a mixed-humid U.S. climate. Summer field data showed that at peak day irradiance the heat transfer penetrating the roof deck dropped almost 90% compared with heat transfer for a conventional roof and attic assembly. The prototype assemblies use a combination of strategies: infrared reflective cool roofs, radiant barriers, above-sheathing ventilation, low-emittance surfaces, insulation, and thermal mass to reduce the attic air temperature and thus the heat transfer into the home. The prototype assemblies exhibited attic air temperatures that did not exceed the peak day outdoor air temperature. Field results were benchmarked against an attic computer tool and simulations made for the densely populated, hot and dry southeastern and central-basin regions of California. New construction in the central basin could realize a 12% drop in ceiling and air-conditioning annual load compared with a code-compliant roof and attic having solar reflectance of 0.25 and thermal emittance of 0.75. In the hot, dry southeastern region of California, the combined ceiling and duct annual load drops by 23% of that computed for a code-compliant roof and attic assembly. Eliminating air leakage from ducts placed in unconditioned attics yielded savings comparable to the best simulated roof and attic systems. Retrofitting an infrared reflective clay tile roof with 1 -in (0.032-m) of EPS foam above the sheathing and improving existing ductwork by reducing air leakage and wrapping ducts with insulation can yield annual savings of about $200 compared with energy costs for pre-1980 construction.

  19. Raising the Roof: California Housing Development Projections and Constraints, 1997-2020

    E-Print Network [OSTI]

    Landis, John D.

    2000-01-01T23:59:59.000Z

    2000-01 Raising the Roof: California Housing Developmentreport, “Raising the Roof: California Housing Developmentat Berkeley Raising the Roof: California Housing Development

  20. Hamerschlag Hall Green Roof Storm Water Retention and Runoff Reduction Performance Lucheng Chen

    E-Print Network [OSTI]

    Andrews, Peter B.

    Hamerschlag Hall Green Roof Storm Water Retention and Runoff Reduction Performance ......................................................................................................................... 2 2. Hamerschlag Hall Green Roof .............................................................................. 13 4. Methods of Storm Analysis and Green Roof Performance Analysis

  1. Achieve Steam System Excellence: Industrial Technologies Program BestPractices Steam Overview Fact Sheet

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: The Future of1 AAccelerated aging of roofingDepartmentAchieve Steam

  2. Detection and location of leaks in district heating steam systems: Survey and review of current technology and practices

    SciTech Connect (OSTI)

    Kupperman, D.S.; Raptis, A.C.; Lanham, R.N.

    1992-03-01T23:59:59.000Z

    This report presents the results of a survey undertaken to identify and characterize current practices for detecting and locating leaks in district heating systems, particular steam systems. Currently used technology and practices are reviewed. In addition, the survey was used to gather information that may be important for the application of acoustic leak detection. A few examples of attempts to locate leaks in steam and hot water pipes by correlation of acoustic signals generated by the leaks are also discussed.

  3. Building Energy Efficiency Standards Approved Default Cool Roof Performance Values for

    E-Print Network [OSTI]

    Building Energy Efficiency Standards Approved Default Cool Roof Performance Values for Low-Sloped Roofs That Use Aggregate As the Surface Layer Aggregate used as the surface layer of low-sloped roofs shall have the default cool roof properties

  4. In-situ aging of roof systems containing polyisocyanurate roof insulation foamed with alternative blowing agents

    SciTech Connect (OSTI)

    Desjarlais, A.O.; Christian, J.E.; Graves, R.S.

    1993-10-01T23:59:59.000Z

    Experimental polyisocyanurate (PIR) foam roof insulations with permeable facers were installed in roofing systems and continuously monitored for thermal performance for four years. The foams were produced using a specific formulation that represented current technology in 1989 and were blown with CFC-11, HCFC-123, and HCFC-141b. These foams were installed in roof systems comprised of loosely-laid insulation boards covered by either a loosely-laid single ply white or black membrane. The in-situ testing was carried out on an outdoor test facility, the Roof Thermal Research Apparatus (RTRA). Additional specimens of these foams were aged in the laboratory and periodically evaluated using laboratory measurement equipment. This paper summarizes the in-situ data compiled to date, compares these data with the laboratory results, and examines whether the proposed laboratory procedure for accelerating the aging of foams by the slicing and scaling method accurately predicts the aging characteristics of these materials installed in roof systems. These experiments are part of a joint industry/government project established to evaluate the technical viability of alternative HCFC blowing agents for rigid closed-cell polyisocyanurate foam roof insulations. Members of the project are the US Department of Energy (DOE)/Oak Ridge National Laboratory (ORNL), the US Environmental Protection Agency (EPA), the Society of the Plastics Industry-Polyurethane Division (SPI), the Polyisocyanurate Insulation Manufacturers Association (PIMA), and the National Roofing Contractors Association (NRCA).

  5. Weathering of Roofing Materials-An Overview

    SciTech Connect (OSTI)

    Berdahl, Paul; Akbari, Hashem; Levinson, Ronnen; Miller, William A.

    2006-03-30T23:59:59.000Z

    An overview of several aspects of the weathering of roofing materials is presented. Degradation of materials initiated by ultraviolet radiation is discussed for plastics used in roofing, as well as wood and asphalt. Elevated temperatures accelerate many deleterious chemical reactions and hasten diffusion of material components. Effects of moisture include decay of wood, acceleration of corrosion of metals, staining of clay, and freeze-thaw damage. Soiling of roofing materials causes objectionable stains and reduces the solar reflectance of reflective materials. (Soiling of non-reflective materials can also increase solar reflectance.) Soiling can be attributed to biological growth (e.g., cyanobacteria, fungi, algae), deposits of organic and mineral particles, and to the accumulation of flyash, hydrocarbons and soot from combustion.

  6. Energy Performance Aspects of a Florida Green Roof Part 2

    E-Print Network [OSTI]

    Sonne, J.; Parker, D.

    Green roof installation in the United States is growing at a significant rate. There are a number of reasons for this growth including rainwater runoff reduction and aesthetic benefits. Energy performance evaluations of green roofs, the subject...

  7. Indirect Benefits (Increased Roof Life and HVAC Savings) from...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Indirect Benefits (Increased Roof Life and HVAC Savings) from a Solar PV System at the San Jos Convention Center Indirect Benefits (Increased Roof Life and HVAC Savings) from a...

  8. Energy Saving 'Cool Roofs' Installed at Y-12 | National Nuclear...

    National Nuclear Security Administration (NNSA)

    Photo Gallery Jobs Apply for Our Jobs Our Jobs Working at NNSA Blog Home NNSA Blog Energy Saving 'Cool Roofs' Installed at Y-12 Energy Saving 'Cool Roofs' Installed at Y-12...

  9. Energy Saving "Cool Roofs" Installed at Y-12 | National Nuclear...

    National Nuclear Security Administration (NNSA)

    Home Field Offices Welcome to the NNSA Production Office NPO News Releases Energy Saving "Cool Roofs" Installed at Y-12 Energy Saving "Cool Roofs" Installed at Y-12 The...

  10. PRESSURIZATION OF FIXED ROOF STORAGE TANKS DUE TO EXTERNAL FIRES

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    PRESSURIZATION OF FIXED ROOF STORAGE TANKS DUE TO EXTERNAL FIRES Fabien FouiHen, INERIS, Parc initiating event of the fire ball observed. In concrete terms, when a fixed roof storage tank is surrounded

  11. Effects of solar photovoltaic panels on roof heat transfer

    E-Print Network [OSTI]

    Dominguez, Anthony; Kleissl, Jan; Luvall, Jeffrey C

    2011-01-01T23:59:59.000Z

    the underside of the tilted solar panels and the surface of the roof under the solar panel (Fig.  2).  An air temperature of the  solar panel is similar to the roof 

  12. Evolution of cool-roof standards in the United States

    E-Print Network [OSTI]

    Akbari, Hashem

    2008-01-01T23:59:59.000Z

    than solar reflectance, thermal emittance, or Energy- Star™solar absorptance and roof-assembly thermal transmittance that yield equal annual energysolar absorptance ? and roof-assembly thermal transmittance U that yield equal annual energy

  13. Energy 101: Cool Roofs | Department of Energy

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville Power AdministrationField Campaign:INEAWaterCool Roofs Energy 101: Cool Roofs Addthis An error

  14. Effect of Surface Mass on Roof Thermal Performance

    E-Print Network [OSTI]

    Wilkes, K. E.; Shipp, P. H.; Sanders, J. P.

    1988-01-01T23:59:59.000Z

    EFFECT OF SURFACE MASS ON ROOF THERMAL PERFORMANCE KENNETH E. WILKES, PAUL H. SHIPP, AND JOHN P. SANDERS Staff Members Oak Ridge National Laboratory Oak Ridge, Tennessee ABSTRACT The roof of a building is exposed to the most severe... of guidelines for the use of surface mass are presented. The experiment on surface mass was carried out at the U.S. Department of Energy Roof Research Center using the Roof Thermal Research Apparatus (RTRA) at the Oak Ridge National Laboratory (ORNL) .4...

  15. Cool Roof Resource Guide for Federal Agencies (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2009-07-01T23:59:59.000Z

    Resource guide containing information and links for the evaluation and installation of cool roofs within the Federal Government

  16. Energy Performance Aspects of a Florida Green Roof

    E-Print Network [OSTI]

    Sonne, J.

    2006-01-01T23:59:59.000Z

    by the University of Central Florida’s Stormwater Management Academy under a grant from the Florida Department of Environmental Protection (FDEP). While the primary purpose of the project is to evaluate rainwater runoff benefits of the green roof, FDEP.... The roof geometry and drainage were designed to allow both the conventional and green roofs to have similar “mirror image” insulation levels and corresponding temperature sensor locations as shown in the roof surface and building section diagrams...

  17. Poster No.: 169 Sulci and Curvature: Detection of the Roof

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Poster No.: 169 Sulci and Curvature: Detection of the Roof Christophe Renault, Michel Desvignes] used the superficial trace of sulci, we detect the roof of the sulci, which presents less intersection the curvature K1 et K2 are equal. Results We have presented a method to extract roof of sulci with a sub

  18. Hamerschlag Hall Green Roof Project Water Monitoring System

    E-Print Network [OSTI]

    Andrews, Peter B.

    1 Hamerschlag Hall Green Roof Project Water Monitoring System Plans and Specifications Created By: David Carothers Date: 2/17/05 #12;2 Hamerschlag Hall Green Roof Project Date: 2/14/05 Created By: David and the flumes shall be water tight. (Figures 1&2) · The connection between the flume and the green roof membrane

  19. Roofing in the Urban Environment: Pollution Source of Opportunity for

    E-Print Network [OSTI]

    Clark, Shirley E.

    ://www.eng.ua.edu/~rpitt Shifting to a more local focus... #12;2 Map courtesy of U.S. Geological Website on Acid Rain Roof Runoff-up roof (plywood + roofing paper/tar) Total: 166 Dissolved: 128 Methodology · Summer 2002: Laboratory exposure to simulated acid rain. · Spring 2003 ­ Fall 2004: Long

  20. Evolution of cool-roof standards in the United States

    SciTech Connect (OSTI)

    Akbari, Hashem; Akbari, Hashem; Levinson, Ronnen

    2008-07-11T23:59:59.000Z

    Roofs that have high solar reflectance and high thermal emittance stay cool in the sun. A roof with lower thermal emittance but exceptionally high solar reflectance can also stay cool in the sun. Substituting a cool roof for a noncool roof decreases cooling-electricity use, cooling-power demand, and cooling-equipment capacity requirements, while slightly increasing heating-energy consumption. Cool roofs can also lower citywide ambient air temperature in summer, slowing ozone formation and increasing human comfort. Provisions for cool roofs in energy-efficiency standards can promote the building- and climate-appropriate use of cool roofing technologies. Cool-roof requirements are designed to reduce building energy use, while energy-neutral cool-roof credits permit the use of less energy-efficient components (e.g., larger windows) in a building that has energy-saving cool roofs. Both types of measures can reduce the life-cycle cost of a building (initial cost plus lifetime energy cost). Since 1999, several widely used building energy-efficiency standards, including ASHRAE 90.1, ASHRAE 90.2, the International Energy Conservation Code, and California's Title 24 have adopted cool-roof credits or requirements. This paper reviews the technical development of cool-roof provisions in the ASHRAE 90.1, ASHRAE 90.2, and California Title 24 standards, and discusses the treatment of cool roofs in other standards and energy-efficiency programs. The techniques used to develop the ASHRAE and Title 24 cool-roof provisions can be used as models to address cool roofs in building energy-efficiency standards worldwide.

  1. Covered Product Category: Cool Roof Products

    Broader source: Energy.gov [DOE]

    FEMP provides acquisition guidance across a variety of product categories, including cool roof products, which are an ENERGY STAR®-qualified product category. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

  2. Development of a Roof Savings Calculator

    SciTech Connect (OSTI)

    New, Joshua Ryan [ORNL] [ORNL; Miller, William A [ORNL] [ORNL; Desjarlais, Andre Omer [ORNL] [ORNL; Erdem, Ender [Lawrence Berkeley National Laboratory (LBNL)] [Lawrence Berkeley National Laboratory (LBNL); Huang, Joe [Lawrence Berkeley National Laboratory (LBNL)] [Lawrence Berkeley National Laboratory (LBNL)

    2011-01-01T23:59:59.000Z

    A web-based Roof Savings Calculator (RSC) has been deployed for the Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors, contractors and researchers easily run complex roof and attic simulations. This tool employs the latest web technologies and usability design to provide an easy input interface to an annual simulation of hour-by-hour, whole-building performance using the world-class simulation tools DOE-2.1E and AtticSim. Building defaults were assigned and can provide estimated annual energy and cost savings after the user selects nothing more than building location. In addition to cool reflective roofs, the RSC tool can simulate multiple roof types at arbitrary inclinations. There are options for above sheathing ventilation, radiant barriers, and low-emittance surfaces. The tool also accommodates HVAC ducts either in the conditioned space or in the attic with custom air leakage rates. Multiple layers of building materials, ceiling and deck insulation, and other parameters can be compared side-by-side to generate an energy/cost savings estimate between two buildings. The RSC tool was benchmarked against field data for demonstration homes in Ft. Irwin, CA.

  3. Development of a Roof Savings Calculator

    SciTech Connect (OSTI)

    New, Joshua Ryan [ORNL] [ORNL; Miller, William A [ORNL] [ORNL; Huang, Joe [Lawrence Berkeley National Laboratory (LBNL)] [Lawrence Berkeley National Laboratory (LBNL); Erdem, Ender [Lawrence Berkeley National Laboratory (LBNL)] [Lawrence Berkeley National Laboratory (LBNL)

    2011-01-01T23:59:59.000Z

    A web-based Roof Savings Calculator (RSC) has been deployed for the Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors, contractors and researchers easily run complex roof and attic simulations. This tool employs the latest web technologies and usability design to provide an easy input interface to an annual simulation of hour-by-hour, whole-building performance using the world-class simulation tools DOE-2.1E and AtticSim. Building defaults were assigned and can provide annual energy and cost savings after the user selects nothing more than building location. In addition to cool reflective roofs, the RSC tool can simulate multiple roof types at arbitrary inclinations. There are options for above sheathing ventilation, radiant barriers and low-emittance surfaces. The tool also accommodates HVAC ducts either in the conditioned space or in the attic with custom air leakage rates. Multiple layers of thermal mass, ceiling insulation and other parameters can be compared side-by-side to generate energy/cost savings between two buildings. The RSC tool was benchmarked against field data for demonstration homes in Ft Irwin, CA.

  4. Thrust bolting: roof bolt support apparatus

    DOE Patents [OSTI]

    Tadolini, Stephen C. (Lakewood, CO); Dolinar, Dennis R. (Golden, CO)

    1992-01-01T23:59:59.000Z

    A method of installing a tensioned roof bolt in a borehole of a rock formation without the aid of a mechanical anchoring device or threaded tensioning threads by applying thrust to the bolt (19) as the bonding material (7') is curing to compress the strata (3) surrounding the borehole (1), and then relieving the thrust when the bonding material (7') has cured.

  5. Update on the Million Solar Roofs Initiative

    SciTech Connect (OSTI)

    Herig, C.

    1999-05-09T23:59:59.000Z

    The Million Solar Roofs Initiative, announced by the President in June of 1997, spans a period of twelve years and intends to increase domestic deployment of solar technologies. This paper presents an overview of the development of the initiative and significant activities to date.

  6. Status of cool roof standards in the United States

    SciTech Connect (OSTI)

    Akbari, Hashem; Levinson, Ronnen

    2007-06-01T23:59:59.000Z

    Since 1999, several widely used building energy efficiency standards, including ASHRAE 90.1, ASHRAE 90.2, the International Energy Conservation Code, and California's Title 24 have adopted cool roof credits or requirements. We review the technical development of cool roof provisions in the ASHRAE 90.1, ASHRAE 90.2, and California Title 24 standards, and discuss the treatment of cool roofs in other standards and energy-efficiency programs. The techniques used to develop the ASHRAE and Title 24 cool roof provisions can be used as models to address cool roofs in building energy standards worldwide.

  7. Evaluation of convex roof entanglement measures

    E-Print Network [OSTI]

    Geza Toth; Tobias Moroder; Otfried Gühne

    2014-10-20T23:59:59.000Z

    We show a powerful method to compute entanglement measures based on convex roof constructions. In particular, our method is applicable to measures that, for pure states, can be written as low order polynomials of operator expectation values. We show how to compute the linear entropy of entanglement, the linear entanglement of assistance, and a bound on the dimension of the entanglement for bipartite systems. We discuss how to obtain the convex roof of the three-tangle for three-qubit states. We also show how to calculate the linear entropy of entanglement and the quantum Fisher information based on partial information or device independent information. We demonstrate the usefulness of our method by concrete examples

  8. PERFORMANCE EVALUATION OF A SUSTAINABLE AND ENERGY EFFICIENT RE-ROOFING TECHNOLOGY USING FIELD-TEST DATA

    SciTech Connect (OSTI)

    Biswas, Kaushik [ORNL; Miller, William A [ORNL; Childs, Phillip W [ORNL; Kosny, Jan [ORNL; Kriner, Scott [Metal Construction Association, Glenview, IL

    2011-01-01T23:59:59.000Z

    Three test attics were constructed to evaluate a new sustainable method of re-roofing utilizing photo-voltaic (PV) laminates, metal roofing panels, and PCM heat sink in the Envelope Systems Research Apparatus (ESRA) facility in the ORNL campus. Figure 1 is a picture of the three attic roofs located adjacent to each other. The leftmost roof is the conventional shingle roof, followed by the metal panel roof incorporating the cool-roof coating, and third from left is the roof with the PCM. On the PCM roof, the PV panels are seen as well; they're labelled from left-to-right as panels 5, 6 and 7. The metal panel roof consists of three metal panels with the cool-roof coating; in further discussion this is referred to as the infrared reflective (IRR) metal roof. The IRR metal panels reflect the incoming solar radiation and then quickly re-emit the remaining absorbed portion, thereby reducing the solar heat gain of the attic. Surface reflectance of the panels were measured using a Solar Spectrum Reflectometer. In the 0.35-2.0 {mu}m wavelength interval, which accounts for more than 94% of the solar energy, the IRR panels have an average reflectance of 0.303. In the infrared portion of the spectrum, the IRR panel reflectance is 0.633. The PCM roof consists of a layer of macro-encapsulated bio-based PCM at the bottom, followed by a 2-cm thick layer of dense fiberglass insulation with a reflective surface on top, and metal panels with pre-installed PV laminates on top. The PCM has a melting point of 29 C (84.2 F) and total enthalpy between 180 and 190 J/g. The PCM was macro-packaged in between two layers of heavy-duty plastic foil forming arrays of PCM cells. Two air cavities, between PCM cells and above the fiberglass insulation, helped the over-the-deck natural air ventilation. It is anticipated that during summer, this extra ventilation will help in reducing the attic-generated cooling loads. The extra ventilation, in conjunction with the PCM heat sink, are used to minimize thermal stresses due to the PV laminates on sunny days. In PV laminates sunlight is converted into electricity and heat simultaneous. In case of building integrated applications, a relatively high solar absorption of amorphous silicon laminates can be utilized during the winter for solar heating purposes with PCM providing necessary heat storage capacity. However, PV laminates may also generate increased building cooling loads during the summer months. Therefore, in this project, the PCM heat sink was to minimize summer heat gains as well. The PCM-fibreglass-PV assembly and the IRR metal panels are capable of being installed directly on top of existing shingle roofs during re-roofing, precluding the need for recycling or disposal of waste materials. The PV laminates installed on the PCM attic are PVL-144 models from Uni-Solar. Each laminate contains 22 triple junction amorphous silicon solar cells connected in series. The silicon cells are of dimensions 356 mm x 239 mm (14-in. x 9.4-in.). The PVL-144 laminate is encapsulated in durable ETFE (poly-ethylene-co-tetrafluoroethylene) high light-transmissive polymer. Table 1 lists the power, voltage and current ratings of the PVL-144 panel.

  9. Aging and weathering of cool roofing membranes

    SciTech Connect (OSTI)

    Akbari, Hashem; Berhe, Asmeret A.; Levinson, Ronnen; Graveline,Stanley; Foley, Kevin; Delgado, Ana H.; Paroli, Ralph M.

    2005-08-23T23:59:59.000Z

    Aging and weathering can reduce the solar reflectance of cool roofing materials. This paper summarizes laboratory measurements of the solar spectral reflectance of unweathered, weathered, and cleaned samples collected from single-ply roofing membranes at various sites across the United States. Fifteen samples were examined in each of the following six conditions: unweathered; weathered; weathered and brushed; weathered, brushed and then rinsed with water; weathered, brushed, rinsed with water, and then washed with soap and water; and weathered, brushed, rinsed with water, washed with soap and water, and then washed with an algaecide. Another 25 samples from 25 roofs across the United States and Canada were measured in their unweathered state, weathered, and weathered and wiped. We document reduction in reflectivity resulted from various soiling mechanisms and provide data on the effectiveness of various cleaning approaches. Results indicate that although the majority of samples after being washed with detergent could be brought to within 90% of their unweathered reflectivity, in some instances an algaecide was required to restore this level of reflectivity.

  10. Generalized roof duality and bisubmodular functions

    E-Print Network [OSTI]

    Kolmogorov, Vladimir

    2010-01-01T23:59:59.000Z

    Consider a convex relaxation $\\hat f$ of a pseudo-boolean function $f$. We say that the relaxation is {\\em totally half-integral} if $\\hat f(\\bx)$ is a polyhedral function with half-integral extreme points $\\bx$, and this property is preserved after adding an arbitrary combination of constraints of the form $x_i=x_j$, $x_i=1-x_j$, and $x_i=\\gamma$ where $\\gamma\\in\\{0, 1, 1/2}$ is a constant. A well-known example is the {\\em roof duality} relaxation for quadratic pseudo-boolean functions $f$. We argue that total half-integrality is a natural requirement for generalizations of roof duality to arbitrary pseudo-boolean functions. Our contributions are as follows. First, we provide a complete characterization of totally half-integral relaxations $\\hat f$ by establishing a one-to-one correspondence with {\\em bisubmodular functions}. Second, we give a new characterization of bisubmodular functions. Finally, we show some relationships between general totally half-integral relaxations and relaxations based on the roof...

  11. EVALUATION OF ROOF BOLTING REQUIREMENTS BASED ON IN-MINE ROOF BOLTER DRILLING

    SciTech Connect (OSTI)

    Syd S. Peng

    2005-01-15T23:59:59.000Z

    In this quarter, the field, theoretical and programming works have been performed toward achieving the research goals set in the proposal. The main accomplishments in this quarter included: (1) one more field test has been conducted in an underground coal mine, (2) optimization studies of the control parameters have been conducted, (3) method to use torque to thrust ratio as indicator of rock relative hardness has also been explored, and (4) about 98% of the development work for the roof geology mapping program, MRGIS, has completed, (5) A real time roof geology mapping system for roof bolters in limestone mine, including a special version of the geology mapping program and hardware, has already been verified to perform very well in underground production condition.

  12. Green Roofs: Federal Energy Management Program (FEMP) Federal Technology Alert

    SciTech Connect (OSTI)

    Scholz-Barth, K.; Tanner, S.

    2004-09-01T23:59:59.000Z

    In a ''green roof,'' a layer of vegetation (e.g., a roof garden) covers the surface of a roof to provide shade, cooler indoor and outdoor temperatures, and effective storm-water management to reduce runoff. The main components are waterproofing, soil, and plants. There are two basic kinds: intensive and extensive. An intensive green roof often features large shrubs and trees, and it can be expensive to install and maintain. An extensive green roof features shallow soil and low-growing, horizontally spreading plants that can thrive in the alpine conditions of many rooftops. These plants do not require a lot of water or soil, and they can tolerate a significant amount of exposure to the sun and wind. This Federal Technology Alert focuses on the benefits, design, and implementation of extensive green roofs and includes criteria for their use on federal facilities.

  13. Fluorescent Pigments for High-Performance Cool Roofing and Facades...

    Energy Savers [EERE]

    dark-colored pigments for cool metal roof and faade coatings that incorporate near-infrared fluorescence and reflectance to improve energy performance. Image: PPG Industries 2...

  14. Flourescent Pigments for High-Performance Cool Roofing and Facades...

    Broader source: Energy.gov (indexed) [DOE]

    dark-colored pigments for cool metal roof and faade coatings that incorporate near-infrared fluorescence and reflectance to improve energy performance. Image: PPG Industries 2...

  15. Evolution of cool-roof standards in the United States

    E-Print Network [OSTI]

    Akbari, Hashem

    2008-01-01T23:59:59.000Z

    CEC. 2006. 2005 Building Energy Efficiency Standards foraddress cool roofs in building energy-efficiency standardsin its “Title 24” Building Energy Efficiency Standards for

  16. Evolution of cool-roof standards in the United States

    E-Print Network [OSTI]

    Akbari, Hashem

    2008-01-01T23:59:59.000Z

    2006. Inclusion of solar reflectance and thermal emittanceuse photovoltaic, solar- thermal, or roof-garden systems2006. Inclusion of solar reflectance and thermal emittance

  17. asphalt roofing shingles: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    and could increase the life of the roof product. However, determining the effects of climate and solar exposure on reflectance and color variability over time is of...

  18. Cool Roof Systems; What is the Condensation Risk?

    SciTech Connect (OSTI)

    Kehrer, Manfred [ORNL; Pallin, Simon B [ORNL

    2014-01-01T23:59:59.000Z

    A white roof, or cool roof, is constructed to decrease thermal loads from solar radiation, therefore saving energy by decreasing the cooling demands. Unfortunately, cool roofs with a mechanically attached membrane have shown a higher risk of intermediate condensation in the materials below the membrane in certain climates (Ennis & Kehrer, 2011) and in comparison with similar constructions with a darker exterior surface (Bludau, Zirkelbach, & Kuenzel, 2009). As a consequence, questions have been raised regarding the sustainability and reliability of using cool roof membranes in northern U.S. climate zones.

  19. Energy Department Completes Cool Roof Installation on DC Headquarters...

    Office of Environmental Management (EM)

    50 degrees cooler. A study by researchers at Lawrence Berkeley National Laboratory (LBNL) found that using cool roofs and cool pavements in cities around the world can help...

  20. Secretary Chu Announces Steps to Implement Cool Roofs at DOE...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    emissions. A recent study by researchers at Lawrence Berkeley National Laboratory (LBNL) found that using cool roofs and cool pavements in cities around the world can help...

  1. Cool roofs as an energy conservation measure for federal buildings

    SciTech Connect (OSTI)

    Taha, Haider; Akbari, Hashem

    2003-04-07T23:59:59.000Z

    We have developed initial estimates of the potential benefits of cool roofs on federal buildings and facilities (building scale) as well as extrapolated the results to all national facilities under the administration of the Federal Energy Management Program (FEMP). In addition, a spreadsheet ''calculator'' is devised to help FEMP estimate potential energy and cost savings of cool roof projects. Based on calculations for an average insulation level of R-11 for roofs, it is estimated that nationwide annual savings in energy costs will amount to $16M and $32M for two scenarios of increased roof albedo (moderate and high increases), respectively. These savings, corresponding to about 3.8 percent and 7.5 percent of the base energy costs for FEMP facilities, include the increased heating energy use (penalties) in winter. To keep the cost of conserved energy (CCE) under $0.08 kWh-1 as a nationwide average, the calculations suggest that the incremental cost for cool roofs should not exceed $0.06 ft-2, assuming that cool roofs have the same life span as their non-cool counterparts. However, cool roofs usually have extended life spans, e.g., 15-30 years versus 10 years for conventional roofs, and if the costs of re-roofing are also factored in, the cutoff incremental cost to keep CCE under $0.08 kWh-1 can be much higher. In between these two ends, there is of course a range of various combinations and options.

  2. aboveground roofed design: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Karagiozis, A.; Desjarlais, A.; Salonvaara, M. 2002-01-01 4 Promoting sustainable green roofs through Leadership in Energy and Environmental Design (LEED). Open Access...

  3. Cool Roofs Will Revolutionize the Building Industry Adoption of infrared-reflective paints is one of the major advances in roofing in our

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    . Cool Roofs Will Revolutionize the Building Industry Adoption of infrared-reflective paints is one of the major advances in roofing in our century. ORNL's Building Envelopes Program has conducted research for many roofing consortiums and their affiliates to help them develop cool roof products. Based

  4. A few words about intermodulation dynamic range and roofing filters: "Roofing filter" is the current buzzword in high-end radios. Just what does it

    E-Print Network [OSTI]

    Allen, Gale

    A few words about intermodulation dynamic range and roofing filters: "Roofing filter" is the current buzzword in high-end radios. Just what does it mean? Basically, a roofing filter is simply to be effective. The term "roofing" stems from the fact that it protects the rest of the radio following it from

  5. Estimating Heat and Mass Transfer Processes in Green Roof Systems: Current Modeling Capabilities and Limitations (Presentation)

    SciTech Connect (OSTI)

    Tabares Velasco, P. C.

    2011-04-01T23:59:59.000Z

    This presentation discusses estimating heat and mass transfer processes in green roof systems: current modeling capabilities and limitations. Green roofs are 'specialized roofing systems that support vegetation growth on rooftops.'

  6. Rooftop Membrane Temperature Reductions with Green Roof Technology in South-Central Texas

    E-Print Network [OSTI]

    Dvorak, B.

    Early green roof cooling and energy reduction research in North America took place in Canada and the northern latitudes of the United States, where green roofs reduced rooftop temperatures by 70% to 90%. Less is known about green roof technology...

  7. A SIMULATION MODEL FOR THE PERFORMANCE ANALYSIS OF ROOF POND SYSTEMS FOR HEATING AND COOLING

    E-Print Network [OSTI]

    Tavana, Medhi

    2011-01-01T23:59:59.000Z

    on Heating Performance of Roof Pond XSL803-6664 Fig. 4.on Heating Performance of Roof Pond Phoenix, Arizona Auguston Cooling Performance of Roof Pond HOur of the doy (solar

  8. Cool roof Q+A 011.doc 29 July 2009 Cool Roof Q & A (draft)

    E-Print Network [OSTI]

    thermal radiation. Thus, a cool roof should have both high "solar reflectance" (ability to reflect, also measured on a scale of 0 to 1). The solar reflectance and thermal emittance of a surface sunlight, measured on a scale of 0 to 1) and high "thermal emittance" (ability to emit thermal radiation

  9. High Efficiency Solar Integrated Roof Membrane Product

    SciTech Connect (OSTI)

    Partyka, Eric; Shenoy, Anil

    2013-05-15T23:59:59.000Z

    This project was designed to address the Solar Energy Technology Program objective, to develop new methods to integrate photovoltaic (PV) cells or modules within a building-integrated photovoltaic (BIPV) application that will result in lower installed cost as well as higher efficiencies of the encapsulated/embedded PV module. The technology assessment and development focused on the evaluation and identification of manufacturing technologies and equipment capable of producing such low-cost, high-efficiency, flexible BIPV solar cells on single-ply roofing membranes.

  10. Cool Roofs | Y-12 National Security Complex

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville Power Administration would likeConstitution AndControllingCool Magnetic Molecules CoolCool Roofs

  11. Cool Roof Calculator | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand JumpConceptual Model, clickInformationNew| Exploration Technique:Illinois: EnergyRoof Calculator

  12. Lafarge Roofing Ltd | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnual SiteofEvaluatingGroup |Jilin Zhongdiantou NewKorea PartsLLNL EnergyLafarge Roofing Ltd Jump

  13. Above the Roof, Beneath the Law: Perceived Justice behind Disruptive Tactics of Migrant Wage Claimants in China

    E-Print Network [OSTI]

    He, X; Wang, L; Su, Y

    2013-01-01T23:59:59.000Z

    bs_bs_banner Above the Roof, Beneath the Law: Perceivedmigrant workers perch on roof tops or towering construction

  14. Daylighter Daily Solar Roof Light | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand JumpConceptual Model,DOE Facility Database DataDatatechnic InternationalMontana:Heights,

  15. Save Energy Now (SEN) Assessment Helps Expand Energy Management Program at Shaw Industries: Flooring Company Saves $872,000 Annually by Improving Steam System Efficiency

    SciTech Connect (OSTI)

    Not Available

    2008-07-01T23:59:59.000Z

    This case study describes how the Shaw Industries plant #20 in Dalton, Georgia, achieved annual savings of $872,000 and 93,000 MMBtu after receiving a DOE Save Energy Now energy assessment and implementing recommendations to improve the efficiency of its steam system.

  16. Fourier analysis of conductive heat transfer for glazed roofing materials

    SciTech Connect (OSTI)

    Roslan, Nurhana Lyana; Bahaman, Nurfaradila; Almanan, Raja Noorliyana Raja; Ismail, Razidah [Faculty of Computer and Mathematical Sciences, Universiti Teknologi MARA, 40450 Shah Alam, Selangor (Malaysia); Zakaria, Nor Zaini [Faculty of Applied Sciences, Universiti Teknologi MARA, 40450 Shah Alam, Selangor (Malaysia)

    2014-07-10T23:59:59.000Z

    For low-rise buildings, roof is the most exposed surface to solar radiation. The main mode of heat transfer from outdoor via the roof is conduction. The rate of heat transfer and the thermal impact is dependent on the thermophysical properties of roofing materials. Thus, it is important to analyze the heat distribution for the various types of roofing materials. The objectives of this paper are to obtain the Fourier series for the conductive heat transfer for two types of glazed roofing materials, namely polycarbonate and polyfilled, and also to determine the relationship between the ambient temperature and the conductive heat transfer for these materials. Ambient and surface temperature data were collected from an empirical field investigation in the campus of Universiti Teknologi MARA Shah Alam. The roofing materials were installed on free-standing structures in natural ventilation. Since the temperature data are generally periodic, Fourier series and numerical harmonic analysis are applied. Based on the 24-point harmonic analysis, the eleventh order harmonics is found to generate an adequate Fourier series expansion for both glazed roofing materials. In addition, there exists a linear relationship between the ambient temperature and the conductive heat transfer for both glazed roofing materials. Based on the gradient of the graphs, lower heat transfer is indicated through polyfilled. Thus polyfilled would have a lower thermal impact compared to polycarbonate.

  17. Hygrothermal Performance of West Coast Wood Deck Roofing System

    SciTech Connect (OSTI)

    Pallin, Simon B [ORNL; Kehrer, Manfred [ORNL; Desjarlais, Andre Omer [ORNL

    2014-02-01T23:59:59.000Z

    Simulations of roofing assemblies are necessary in order to understand and adequately predict actual the hygrothermal performance. At the request of GAF, simulations have been setup to verify the difference in performance between white and black roofing membrane colors in relation to critical moisture accumulation for traditional low slope wood deck roofing systems typically deployed in various western U.S. Climate Zones. The performance of these roof assemblies has been simulated in the hygrothermal calculation tool of WUFI, from which the result was evaluated based on a defined criterion for moisture safety. The criterion was defined as the maximum accepted water content for wood materials and the highest acceptable moisture accumulation rate in relation to the risk of rot. Based on the criterion, the roof assemblies were certified as being either safe, risky or assumed to fail. The roof assemblies were simulated in different western climates, with varying insulation thicknesses, two different types of wooden decking, applied with varying interior moisture load and with either a high or low solar absorptivity at the roof surface (black or white surface color). The results show that the performance of the studied roof assemblies differs with regard to all of the varying parameters, especially the climate and the indoor moisture load.

  18. Roofing in the Urban Environment: Pollution Source of Opportunity for

    E-Print Network [OSTI]

    Clark, Shirley E.

    ://www.eng.ua.edu/~rpitt #12;2 Map courtesy of U.S. Geological Website on Acid Rain Roof Runoff Concentrations: Western + roofing paper/tar) Total: 166 Dissolved: 128 : Laboratory exposure to simulated acid rain. · Spring 2003 ­ Fall 2004: Long-term, outdoor investigation from

  19. Visual Analytics for Roof Savings Calculator Ensembles

    SciTech Connect (OSTI)

    Jones, Chad [University of California, Davis] [University of California, Davis; New, Joshua Ryan [ORNL] [ORNL; Sanyal, Jibonananda [ORNL] [ORNL; Ma, Kwan-Liu [University of California, Davis] [University of California, Davis

    2012-01-01T23:59:59.000Z

    The Roof Savings Calculator (RSC) has been deployed for DOE as an industry-consensus, web-based tool for easily running complex building energy simulations. These simulations allow both homeowners and experts to determine building-specific cost and energy savings for modern roof and attic technologies. Using a database of over 3 million RSC simulations for different combinations of parameters, we have built a visual analytics tool to assist in the exploration and identification of features in the data. Since the database contains multiple variables, both categorical and continuous, we employ a coordinated multi-view approach that allows coordinated feature exploration through multiple visualizations at once. The main component of our system, a parallel coordinates view, has been adapted to handle large-scale, mixed data types as are found in RSC simulations. Other visualizations include map coordinated plots, high dynamic range (HDR) line plot rendering, and an intuitive user interface. We demonstrate these techniques with several use cases that have helped identify software and parametric simulation issues.

  20. Effectiveness of Cool Roof Coatings with Ceramic Particles

    SciTech Connect (OSTI)

    Brehob, Ellen G [ORNL] [ORNL; Desjarlais, Andre Omer [ORNL] [ORNL; Atchley, Jerald Allen [ORNL] [ORNL

    2011-01-01T23:59:59.000Z

    Liquid applied coatings promoted as cool roof coatings, including several with ceramic particles, were tested at Oak Ridge National Laboratory (ORNL), Oak Ridge, Tenn., for the purpose of quantifying their thermal performances. Solar reflectance measurements were made for new samples and aged samples using a portable reflectometer (ASTM C1549, Standard Test Method for Determination of Solar Reflectance Near Ambient Temperature Using a Portable Solar Reflectometer) and for new samples using the integrating spheres method (ASTM E903, Standard Test Method for Solar Absorptance, Reflectance, and Transmittance of Materials Using Integrating Spheres). Thermal emittance was measured for the new samples using a portable emissometer (ASTM C1371, Standard Test Method for Determination of Emittance of Materials Near Room 1 Proceedings of the 2011 International Roofing Symposium Temperature Using Portable Emissometers). Thermal conductivity of the coatings was measured using a FOX 304 heat flow meter (ASTM C518, Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus). The surface properties of the cool roof coatings had higher solar reflectance than the reference black and white material, but there were no significant differences among coatings with and without ceramics. The coatings were applied to EPDM (ethylene propylene diene monomer) membranes and installed on the Roof Thermal Research Apparatus (RTRA), an instrumented facility at ORNL for testing roofs. Roof temperatures and heat flux through the roof were obtained for a year of exposure in east Tennessee. The field tests showed significant reduction in cooling required compared with the black reference roof (~80 percent) and a modest reduction in cooling compared with the white reference roof (~33 percent). The coating material with the highest solar reflectivity (no ceramic particles) demonstrated the best overall thermal performance (combination of reducing the cooling load cost and not incurring a large heating penalty cost) and suggests solar reflectivity is the significant characteristic for selecting cool roof coatings.

  1. Lighting

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville PowerCherries 82981-1cnHigh SchoolIn12electron 9 5Let us countLighting Sign In About | Careers |

  2. EVALUATION OF ROOF BOLTING REQUIREMENTS BASED ON IN-MINE ROOF BOLTER DRILLING

    SciTech Connect (OSTI)

    Syd S. Peng

    2005-04-15T23:59:59.000Z

    In this quarter, the field, theoretical and programming works have been performed toward achieving the research goals set in the proposal. The main accomplishments in this quarter included: (1) one more field test has been conducted in an underground coal mine, (2) optimization studies of the control parameters have been conducted, (3) the relationship among feed pressure, penetration rate and rotation rate seems to be a good indicator for estimating rock strength when both penetration rate and rotation rate are controlled or kept constant, (4) the empirical equations for eliminating the machine effect on drilling parameters were developed and verified, and (5) a real time roof geology mapping system for roof bolters in limestone mine, including a special version of the geology mapping program and hardware, performs very well in underground production condition.

  3. EVALUATION OF ROOF BOLTING REQUIREMENTS BASED ON IN-MINE ROOF BOLTER DRILLING

    SciTech Connect (OSTI)

    Syd S. Peng

    2001-04-15T23:59:59.000Z

    In this quarter, the research effort is to develop the drill control unit (DCU) that acquire, store drilling parameters and control the drilling operation. The relevant publications have been reviewed and the methodology developed by previous researchers has been evaluated using the collected data in our laboratory and field tests conducted prior to the start of this project. Numerical modeling for exploring roof bolting mechanism has been started.

  4. Flexible shaft and roof drilling system

    DOE Patents [OSTI]

    Blanz, John H. (Carlisle, MA)

    1981-01-01T23:59:59.000Z

    A system for drilling holes in the roof of a mine has a flexible shaft with a pair of oppositely wound, coaxial flat bands. One of the flat bands defines an inner spring that is wound right handed into a helical configuration, adjacent convolutions being in nesting relationship to one another. The other flat band defines an outer spring that is wound left handed into a helical configuration about the inner band, adjacent convolutions being nesting relationship with one another. A transition member that is configured to hold a rock bit is mounted to one end of the flexible shaft. When torque and thrust are applied to the flexible shaft by a driver, the inner spring expands outwardly and the outer spring contracts inwardly to form a relatively rigid shaft.

  5. Roof Replacement and Related Work February 17, 2000 DSR # 0000-00 XXX

    E-Print Network [OSTI]

    Roof Replacement and Related Work February 17, 2000 DSR # 0000-00 XXX SECTION 02072 - REMOVAL OF INTACT INCIDENTAL ASBESTOS CONTAINING ROOFING MATERIAL (Rev.9/00) PART 1 - GENERAL 1.1 RELATED DOCUMENTS Roof System Components Chart" for location of asbestos containing roofing materials. 1.2 SUMMARY A

  6. RESEARCH ARTICLE An experimental study of flow fields and wind loads on gable-roof

    E-Print Network [OSTI]

    Hu, Hui

    RESEARCH ARTICLE An experimental study of flow fields and wind loads on gable-roof building models the resultant wind loads acting on low-rise, gable-roof buildings induced by violent microburst-like winds State University. Two gable-roof building models with the same base plan and mean roof height

  7. Generalized Roof Duality for Pseudo-Boolean Optimization Fredrik Kahl Petter Strandmark

    E-Print Network [OSTI]

    Lunds Universitet

    Generalized Roof Duality for Pseudo-Boolean Optimization Fredrik Kahl Petter Strandmark Centre to a quadratic pseudo-boolean function, and then use roof duality for ob- taining a lower bound. Roof duality to polynomials of higher degree, where quadratic roof duality appears as a special case. Op- timal relaxations

  8. Thermal Performance of Vegetative Roofing Systems Andre O. Desjarlais, Abdi Zaltash, and Jerald A. Atchley

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    Thermal Performance of Vegetative Roofing Systems Andre O. Desjarlais, Abdi Zaltash, and Jerald A purposes. #12;ABSTRACT Vegetative roofing, otherwise known as green or garden roofing, has seen tremendous growth in the last decade in the United States. The numerous benefits that green roofs provide have

  9. A novel technique for the production of cool colored concrete tile and asphalt shingle roofing products

    SciTech Connect (OSTI)

    Levinson, Ronnen; Akbari, Hashem; Berdahl, Paul; Wood, Kurt; Skilton, Wayne; Petersheim, Jerry

    2009-11-20T23:59:59.000Z

    The widespread use of solar-reflective roofing materials can save energy, mitigate urban heat islands and slow global warming by cooling the roughly 20% of the urban surface that is roofed. In this study we created prototype solar-reflective nonwhite concrete tile and asphalt shingle roofing materials using a two-layer spray coating process intended to maximize both solar reflectance and factory-line throughput. Each layer is a thin, quick-drying, pigmented latex paint based on either acrylic or a poly(vinylidene fluoride)/acrylic blend. The first layer is a titanium dioxide rutile white basecoat that increases the solar reflectance of a gray-cement concrete tile from 0.18 to 0.79, and that of a shingle surfaced with bare granules from 0.06 to 0.62. The second layer is a 'cool' color topcoat with weak near-infrared (NIR) absorption and/or strong NIR backscattering. Each layer dries within seconds, potentially allowing a factory line to pass first under the white spray, then under the color spray. We combined a white basecoat with monocolor topcoats in various shades of red, brown, green and blue to prepare 24 cool color prototype tiles and 24 cool color prototypes shingles. The solar reflectances of the tiles ranged from 0.26 (dark brown; CIELAB lightness value L* = 29) to 0.57 (light green; L* = 76); those of the shingles ranged from 0.18 (dark brown; L* = 26) to 0.34 (light green; L* = 68). Over half of the tiles had a solar reflectance of at least 0.40, and over half of the shingles had a solar reflectance of at least 0.25.

  10. Evaporative Roof Cooling- A Simple Solution to Cut Cooling Costs

    E-Print Network [OSTI]

    Abernethy, D.

    Since the “Energy Crisis” Evaporative Roof Cooling Systems have gained increased acceptance as a cost effective method to reduce the high cost of air conditioning. Documented case histories in retro-fit installations show direct energy savings...

  11. Effects of solar photovoltaic panels on roof heat transfer

    E-Print Network [OSTI]

    Dominguez, Anthony; Kleissl, Jan; Luvall, Jeffrey C

    2011-01-01T23:59:59.000Z

    comes from both the solar panel and the sky weighted by the underside of the tilted solar panels and the surface of of a roof  underneath a solar panel compared to that of an 

  12. Plain Talk About Condensation and Radiation Below Metal Roof Assemblies

    E-Print Network [OSTI]

    Ward, L.

    . Unfortunately, some of these advantages may give rise to certain disadvantages in comfort, durability and operating costs (7) This paper provides a brief historical overview of common metal roof insulation methods as well as recent innovations for low cost... assemblies. INTRODUCTION A primary objective of this paper is to try and simplify the complex subject of condensation in metal roof assemblies. A secondary objective is to focus on condensation considerations with reflective insulation systems (as...

  13. EVALUATION OF ROOF BOLTING REQUIREMENTS BASED ON IN MINE ROOF BOLTER DRILLING

    SciTech Connect (OSTI)

    Syd S. Peng

    2003-10-15T23:59:59.000Z

    In this quarter, the field, theoretical and programming works have been performed toward achieving the research goals set in the proposal. The main accomplishments in this quarter included: (1) laboratory tests have been conducted, (2) with the added trendline analysis method, the accuracy of the data interpretation methodology will be improved, (3) method to use torque to thrust ratio as indicator of rock relative hardness has also been explored, and (3) about one half of the development work for the roof geology mapping program, MRGIS, has completed.

  14. Inclusion of cool roofs in nonresidential Title 24 prescriptive requirements

    SciTech Connect (OSTI)

    Levinson, Ronnen; Akbari, Hashem; Konopacki, Steve; Bretz, Sarah

    2002-12-15T23:59:59.000Z

    Roofs that have high solar reflectance (high ability to reflect sunlight) and high thermal emittance (high ability to radiate heat) tend to stay cool in the sun. The same is true of low-emittance roofs with exceptionally high solar reflectance. Substituting a cool roof for a noncool roof tends to decrease cooling electricity use, cooling power demand, and cooling-equipment capacity requirements, while slightly increasing heating energy consumption. Cool roofs can also lower the ambient air temperature in summer, slowing ozone formation and increasing human comfort. DOE-2.1E building energy simulations indicate that use of a cool roofing material on a prototypical California nonresidential building with a low-sloped roof yields average annual cooling energy savings of approximately 300 kWh/1000 ft2 [3.2 kWh/m2], average annual natural gas deficits of 4.9 therm/1000 ft2 [5.6 MJ/m2], average source energy savings of 2.6 MBTU/1000 ft2 [30 MJ/m2], and average peak power demand savings of 0. 19 kW/1000 ft2 [2.1 W/m2]. The 15-year net present value (NPV) of energy savings averages $450/1000 ft2 [$4.90/m2] with time dependent valuation (TDV), and $370/1000 ft2 [$4.00/m2] without TDV. When cost savings from downsizing cooling equipment are included, the average total savings (15-year NPV + equipment savings) rises to $550/1000 ft2 [$5.90/m2] with TDV, and to $470/1000 ft2 [$5.00/m2] without TDV. Total savings range from 0.18 to 0.77 $/ft2 [1.90 to 8.30 $/m2] with TDV, and from 0.16 to 0.66 $/ft2 [1.70 to 7.10 $/m2] without TDV, across California's 16 climate zones. The typical cost premium for a cool roof is 0.00 to 0.20 $/ft2 [0.00 to 2.20 $/m2]. Cool roofs with premiums up to $0.20/ft2 [$2.20/m2] are expected to be cost effective in climate zones 2 through 16; those with premiums not exceeding $0.18/ft2 [$1.90/m2] are expected to be also cost effective in climate zone 1. Hence, this study recommends that the year-2005 California building energy efficiency code (Title 24, Pa rt 6 of the California Code of Regulations) for nonresidential buildings with low-sloped roofs include a cool-roof prescriptive requirement in all California climate zones. Buildings with roofs that do not meet prescriptive requirements may comply with the code via an ''overall-envelope'' approach (non-metal roofs only), or via a performance approach (all roof types).

  15. Comparison of Software Models for Energy Savings from Cool Roofs

    SciTech Connect (OSTI)

    New, Joshua Ryan [ORNL; Miller, William A [ORNL; Huang, Yu (Joe) [White Box Technologies; Levinson, Ronnen [Lawrence Berkeley National Laboratory (LBNL)

    2014-01-01T23:59:59.000Z

    A web-based Roof Savings Calculator (RSC) has been deployed for the United States Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors, contractors and researchers easily run complex roof and attic simulations. This tool employs modern web technologies, usability design, and national average defaults as an interface to annual simulations of hour-by-hour, whole-building performance using the world-class simulation tools DOE-2.1E and AtticSim in order to provide estimated annual energy and cost savings. In addition to cool reflective roofs, RSC simulates multiple roof and attic configurations including different roof slopes, above sheathing ventilation, radiant barriers, low-emittance roof surfaces, duct location, duct leakage rates, multiple substrate types, and insulation levels. A base case and energy-efficient alternative can be compared side-by-side to estimate monthly energy. RSC was benchmarked against field data from demonstration homes in Ft. Irwin, California; while cooling savings were similar, heating penalty varied significantly across different simulation engines. RSC results reduce cool roofing cost-effectiveness thus mitigating expected economic incentives for this countermeasure to the urban heat island effect. This paper consolidates comparison of RSC s projected energy savings to other simulation engines including DOE-2.1E, AtticSim, Micropas, and EnergyPlus, and presents preliminary analyses. RSC s algorithms for capturing radiant heat transfer and duct interaction in the attic assembly are considered major contributing factors to increased cooling savings and heating penalties. Comparison to previous simulation-based studies, analysis on the force multiplier of RSC cooling savings and heating penalties, the role of radiative heat exchange in an attic assembly, and changes made for increased accuracy of the duct model are included.

  16. Global Cooling: Policies to Cool the World and Offset Global Warming from CO2 Using Reflective Roofs and Pavements

    E-Print Network [OSTI]

    Akbari, Hashem

    2010-01-01T23:59:59.000Z

    cooling load from cool roofs. While important, the annual CO2008. Evolution of cool roof standards in the United States.2005. “Cool Colored Roofs to Save Energy and Improve Air

  17. Steam System Optimization

    E-Print Network [OSTI]

    Aegerter, R. A.

    flanges, control valves, steam turbines, manways, sections of piping, heads on vessels, etc. are uninsulated. If steam is in demand at the steam pressure level of the uninsulated piping and equipment, then the piping and equipment should be insulated... been developed, it is an excellent tool to identify the steam sources. Areas to first look for possible waste are steam turbines and steam let down stations. 161 ESL-IE-98-04-26 Proceedings from the Twentieth National Industrial Energy Technology...

  18. Steam System Optimization

    E-Print Network [OSTI]

    Aegerter, R.

    2004-01-01T23:59:59.000Z

    opportunities. Often flanges, control valves, steam turbines, man ways, sections of piping, heads on vessels, etc. are bare and can significantly increase the steam demand. An insulation survey should be conducted of the steam, condensate... is being let down. Some projects are independent of the steam balance, such as eliminating high-pressure (HP) steam leaks, insulating HP steam piping, optimizing the boiler operation, and improving the performance of condensing turbines...

  19. Steam System Optimization 

    E-Print Network [OSTI]

    Aegerter, R. A.

    1998-01-01T23:59:59.000Z

    been developed, it is an excellent tool to identify the steam sources. Areas to first look for possible waste are steam turbines and steam let down stations. 161 ESL-IE-98-04-26 Proceedings from the Twentieth National Industrial Energy Technology... Conference, Houston, TX, April 22-23, 1998 The easiest solution to eliminating excess steam is to shut down steam turbines that exhaust into the header and start up the motor driven spare equipment. Often times this step will be enough to eliminate...

  20. Steam System Losses

    E-Print Network [OSTI]

    Buchanan, M. G.; Sneary, M. L.

    energy into the air. You might say that many of us are increasing the relative humidity of our respective cities. Before a conventional pump package can handle steam condensate, that fluid must be cooled to somewhere below 180 0 ? This cooling... are increasing the relative humidity of our respective cities. Before a conventional pump package can handle steam condensate, that fluid must be cooled to somewhere below 180 0 . This cooling is accomplished by venting the receiver to the atmosphere...

  1. Steam System Survey Guide

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn'tOriginEducationVideo »UsageSecretaryVideosSpringoutAPBF-DEC NOxBestPractices SteamOffice of1/263

  2. Empirically Derived Strength of Residential Roof Structures for Solar Installations.

    SciTech Connect (OSTI)

    Dwyer, Stephen F.; Sanchez, Alfred; Campos, Ivan A.; Gerstle, Walter H.

    2014-12-01T23:59:59.000Z

    Engineering certification for the installation of solar photovoltaic (PV) modules on wood roofs is often denied because existing wood roofs do not meet structural design codes. This work is intended to show that many roofs are actually sufficiently strong given the conservatism in codes, documented allowable strengths, roof structure system effects, and beam composite action produced by joist-sheathing interaction. This report provides results from a testing program to provide actual load carrying capacity of residential rooftops. The results reveal that the actual load carrying capacity of structural members and systems tested are significantly stronger than allowable loads provided by the International Residential Code (IRC 2009) and the national structural code found in Minimum Design Loads for Buildings and Other Structures (ASCE 7-10). Engineering analysis of residential rooftops typically ignores the system affects and beam composite action in determining rooftop stresses given a potential PV installation. This extreme conservatism combined with conservatism in codes and published allowable stress values for roof building materials (NDS 2012) lead to the perception that well built homes may not have adequate load bearing capacity to enable a rooftop PV installation. However, based on the test results presented in this report of residential rooftop structural systems, the actual load bearing capacity is several times higher than published values (NDS 2012).

  3. Apparatus for thermal performance measurements of insulated roof systems

    SciTech Connect (OSTI)

    Courville, G.E.; Childs, K.W.; Walukas, D.J.; Childs, P.W.; Griggs, E.I.

    1984-01-01T23:59:59.000Z

    The US Department of Energy conducted thermal performance measurements on low-slope roofs with a recently developed field test apparatus at Oak Ridge National Laboratory (ORNL). The apparatus accommodates four 4 ft x 8 ft test specimens and includes the measurement capabilities for specimen temperatures, temperature gradients, heat flows and moisture content. A weather station characterizes outdoor weather conditions. Tests underway include (1) validation of a roof surface temperature model developed to study the effects of wet insulation; (2) measurement of temperature distributions and heat transfer in high R-value roofs; and (3) validation of an analysis of the effectiveness of high reflectance surfaces. Preliminary experimental results are presented and correlations between experiment and modeling are discussed.

  4. Reducing roof fall accidents on retreat mining sections

    SciTech Connect (OSTI)

    Mark, C.; Zelanko, J.C. [National Institute for Occupational Safety and Health (NIOSH) (United States). Rock Mechanics Section

    2005-12-15T23:59:59.000Z

    Pillar recovery continues to be one of the most hazardous activities in underground mining. Global stability, achieved through proper pillar design, is a necessary prerequisite for safe pillar recovery. Local stability means preventing roof falls in the working area. It is achieved by minimizing the 'risk factors' described in this paper. Roof Control Plans developed at each underground coal mine often address both engineering parameters and human behavior issues. These plans are essential to all mining activities, but nowhere are they more important than in pillar recovery. Pillaring leaves little tolerance for error, and mistakes can be deadly. Roof Control Plans must be carefully drawn up to address site-specific conditions, and then carefully implemented and followed. Miners and foremen involved in pillar extraction should be trained to know and understand the plan prior to beginning retreat mining. More details can be found at www.cdc.gov/niosh/mining/pubs/pdfs/rtrog.pdf. 3 figs.

  5. Tangles of superpositions and the convex-roof extension

    E-Print Network [OSTI]

    Andreas Osterloh; Jens Siewert; Armin Uhlmann

    2007-10-31T23:59:59.000Z

    We discuss aspects of the convex-roof extension of multipartite entanglement measures, that is, $SL(2,\\CC)$ invariant tangles. We highlight two key concepts that contain valuable information about the tangle of a density matrix: the {\\em zero-polytope} is a convex set of density matrices with vanishing tangle whereas the {\\em convex characteristic curve} readily provides a non-trivial lower bound for the convex roof and serves as a tool for constructing the convex roof outside the zero-polytope. Both concepts are derived from the tangle for superpositions of the eigenstates of the density matrix. We illustrate their application by considering examples of density matrices for two-qubit and three-qubit states of rank 2, thereby pointing out both the power and the limitations of the concepts.

  6. EVALUATION OF ROOF BOLTING REQUIREMENTS BASED ON IN-MINE ROOF BOLTER DRILLING

    SciTech Connect (OSTI)

    Syd S. Peng

    2004-04-15T23:59:59.000Z

    A one-year non-cost extension has been granted for this project. In this quarter, the field, theoretical and programming works have been performed toward achieving the research goals set in the proposal. The main accomplishments in this quarter included: (1) laboratory tests have been conducted, (2) with the added trendline analysis method, the accuracy of the data interpretation methodology will be improved and the interfaces and voids can be more reliably detected, (3) method to use torque to thrust ratio as indicator of rock relative hardness has also been explored, and (3) about 80% of the development work for the roof geology mapping program, MRGIS, has completed and a special version of the program is in the field testing stage.

  7. You Don't Need to Raise the Roof: Cutting Solar Permitting Costs...

    Office of Environmental Management (EM)

    You Don't Need to Raise the Roof: Cutting Solar Permitting Costs for Wooden Rooftops You Don't Need to Raise the Roof: Cutting Solar Permitting Costs for Wooden Rooftops June 17,...

  8. Research on the Effect of a Planting Roof on the Thermal Load of a Business Building 

    E-Print Network [OSTI]

    Zhang, W.; Wu, J.; Wei, Y.; Gao, X.

    2006-01-01T23:59:59.000Z

    A pair of comparative testing rooms (one with an ordinary roof and the other with a planting roof) was established in our laboratory, and in- situ measurement (in summer) data have been collected and treated. The indoor ...

  9. Conservation of stone-roofs: Challenges and the effect of new Techniques 

    E-Print Network [OSTI]

    Teba, Tarek

    Stone-roofing has a great history which spans many millennia BC which witnessed a lot of development to roofing systems and geometry regarding the area and type of building demands. Therefore, this paper discusses this ...

  10. Asphalt roofing industry Fourier transform infrared spectroscopy modified bitumen

    SciTech Connect (OSTI)

    NONE

    1999-07-01T23:59:59.000Z

    A Request for Emissions Testing at Four Asphalt Roofing and Processing Facilities was submitted by the US EPA Emission Standards Division (ESD), Minerals and Inorganic Chemicals Group (MICG) to the Emission Measurement Center (EMC). The Emission Measurement Center directed Midwest Research Institute (MRI) to conduct emissions testing at asphalt roofing plants. This report presents results of MRI`s FTIR and Method 25A testing conducted at US Intec in Port Arthur, Texas. The field measurements were performed in September 1997 under several test conditions for both controlled and uncontrolled emissions.

  11. Preliminary Analysis of Energy Consumption for Cool Roofing Measures

    SciTech Connect (OSTI)

    Mellot, Joe [The Garland Company] [The Garland Company; Sanyal, Jibonananda [ORNL] [ORNL; New, Joshua Ryan [ORNL] [ORNL

    2013-01-01T23:59:59.000Z

    The spread of cool roofing has been more than prolific over the last decade. Driven by public demand and by government initiatives cool roofing has been a recognized low cost method to reduce energy demand by reflecting sunlight away from structures and back in to the atmosphere. While much of the country can benefit from the use of cool coatings it remains to be seen whether the energy savings described are appropriate in cooler climates. By use of commonly available calculators one can analyze the potential energy savings based on environmental conditions and construction practices.

  12. Sustainable Retrofit of Residential Roofs Using Metal Roofing Panels, Thin-Film Photovoltaic Laminates, and PCM Heat Sink Technology

    SciTech Connect (OSTI)

    Kosny, Jan [ORNL] [ORNL; Miller, William A [ORNL] [ORNL; Childs, Phillip W [ORNL] [ORNL; Biswas, Kaushik [ORNL] [ORNL

    2011-01-01T23:59:59.000Z

    During September-October 2009, research teams representing Metal Construction Association (the largest North American trade association representing metal building manufacturers, builders, and material suppliers), CertainTeed (one of the largest U.S. manufacturers of thermal insulation and building envelope materials), Unisolar (largest U.S. producer of amorphous silicone photo-voltaic (PV) laminates), Phase Change Energy (manufacturer of bio-based PCM), and Oak Ridge National Laboratory (ORNL) installed three experimental attics utilizing different roof retrofit strategies in the ORNL campus. The main goal of this project was experimental evaluation of a newly-developed sustainable re-roofing technology utilizing amorphous silicone PV laminates integrated with metal roof and PCM heat sink. The experimental attic with PV laminate was expected to work during the winter time as a passive solar collector with PCM storing solar heat, absorbed during the day, and increasing overall attic air temperature during the night.

  13. Decay of correlations for flows with unbounded roof function, including the infinite horizon planar

    E-Print Network [OSTI]

    Decay of correlations for flows with unbounded roof function, including the infinite horizon planar for studying nonuniformly hyperbolic flows with unbounded roof functions. In particular, we establish the decay of other classes of flows with unbounded roof functions. For geometric Lorenz attractors (in- cluding

  14. Uncertainty analysis and validation of the estimation of effective hydraulic properties: application to green roof

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    : application to green roof substrate A. Mesgoueza,b, , S. Buisb,a , S. Ruyb,a , G. Lefeuve on determining the effective properties at the Darcy scale of green roof substrates (GRS), highly heterogeneous of composite porous materials in order to improve the hydraulic functioning of green roof sub- strates

  15. Development/Plasticity/Repair The Bone Morphogenetic Protein Roof Plate Chemorepellent

    E-Print Network [OSTI]

    Butler, Samantha

    Development/Plasticity/Repair The Bone Morphogenetic Protein Roof Plate Chemorepellent Regulates, Toronto, Ontario, Canada M5G 1X8 Commissural spinal axons extend away from the roof plate (RP) in response to the dorsal midline and are generated by the bone morphogenetic proteins (BMPs) in the roof plate (RP) (Liem

  16. BUILDING ROOF SEGMENTATION AND RECONSTRUCTION FROM LIDAR POINT CLOUDS USING CLUSTERING TECHNIQUES

    E-Print Network [OSTI]

    Shan, Jie

    BUILDING ROOF SEGMENTATION AND RECONSTRUCTION FROM LIDAR POINT CLOUDS USING CLUSTERING TECHNIQUES presents an approach to creating a polyhedral model of building roof from LiDAR point clouds using. The normal vectors are then clustered together to determine the principal directions of the roof planes

  17. VEGETATED ROOFS FOR URBAN ECOSYSTEM REMEDIATION: PERFORMANCE AND POLICY IN THE TANYARD BRANCH WATERSHED

    E-Print Network [OSTI]

    Rosemond, Amy Daum

    VEGETATED ROOFS FOR URBAN ECOSYSTEM REMEDIATION: PERFORMANCE AND POLICY IN THE TANYARD BRANCH the urbanization process. This study evaluated the performance and feasibility of using vegetated or green roof systems for urban ecosystem remediation. The stormwater retention performance of a thin-layer green roof

  18. Simulation of Heat Exchange Phenomena and Water Regime in Green Roof Substrates

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    187 Simulation of Heat Exchange Phenomena and Water Regime in Green Roof Substrates S. Charpentier UR EPHor Agrocampus-Ouest Centre d'Angers 2, rue Le Nôtre, F49045 Angers France Keywords: green roof roofs increases in Western European and North American cities. It is estimated that 12% of all flat

  19. Cool Roofs and Global Cooling Surabi Menon, Ronnen Levinson, Marc Fischer, Dev Millstein,

    E-Print Network [OSTI]

    Cool Roofs and Global Cooling Surabi Menon, Ronnen Levinson, Marc Fischer, Dev Millstein, Nancy potential of reflective (or white or cool) surfaces such as roofs and pavements. However, the article's results regarding white roofs are preliminary and uncertain. Moreover there are other published papers

  20. Decay of correlations for flows with unbounded roof function, including the infinite horizon planar

    E-Print Network [OSTI]

    Decay of correlations for flows with unbounded roof function, including the infinite horizon planar for studying nonuniformly hyperbolic flows with unbounded roof functions. In particular, we establish the decay of other classes of flows with unbounded roof functions. For geometric Lorenz attractors (in­ cluding

  1. ORNL Roof and Attic System Shows Efficient Retrofit By Zaher Karp Reuters, July 27, 2009

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    ORNL Roof and Attic System Shows Efficient Retrofit Option By Zaher Karp ­ Reuters, July 27, 2009 A new roof and attic system developed at the Oak Ridge National Laboratory Building Technology Center. Texas-based Billy Ellis Roofing funds the research through the Building Technology Center

  2. Behavior of Reinforced Concrete ColumnSteel Beam Roof Level T-Connections under Displacement Reversals

    E-Print Network [OSTI]

    Parra-Montesinos, Gustavo J.

    Behavior of Reinforced Concrete Column­Steel Beam Roof Level T-Connections under Displacement study on the seismic response of two hybrid RC column-to-steel S beam RCS roof level T longitudinal bars; and 2 confinement requirements in RCS roof level T-connections. In the first subassembly

  3. Tighter Relaxations for Higher-Order Models based on Generalized Roof Duality

    E-Print Network [OSTI]

    Lunds Universitet

    Tighter Relaxations for Higher-Order Models based on Generalized Roof Duality Johan Fredriksson one of the most successful approaches, namely roof duality, for approximately solving such problems cone. In the sec- ond method, it is shown that the roof dual bound can be applied in an iterated way

  4. Modelling the Zn emissions from roofing materials at Crteil city scale -Defining a methodology

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Modelling the Zn emissions from roofing materials at Créteil city scale - Defining a methodology@cereve.enpc.fr) Abstract Today, urban runoff is considered as an important source of environment pollution. Roofing. An accurate evaluation of contaminant flows from roofs is thus required at the city scale. This paper aims

  5. Effect of the open roof on low frequency acoustic propagation in street canyons

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Effect of the open roof on low frequency acoustic propagation in street canyons O. Richoux, C of the effect of open roof on acoustic propagation along a 3D urban canyon. The experimental study is led Domain approach adapted to take into account the acoustic radiation losses due to the street open roof

  6. A COST BASED APPROACH TO DESIGN OF RESIDENTIAL STEEL ROOF SYSTEMS

    E-Print Network [OSTI]

    Mobasher, Barzin

    A COST BASED APPROACH TO DESIGN OF RESIDENTIAL STEEL ROOF SYSTEMS B. Mobasher1 , S-Y.Chen2 , C-5306 Abstract A comprehensive system for the design of residential steel roof truss systems is presented automatically design a roof truss given minimal input and using the design curves as the performance constraints

  7. Inclusion of cool roofs in nonresidential Title 24 prescriptiverequirements

    SciTech Connect (OSTI)

    Levinson, Ronnen; Akbari, Hashem; Konopacki, Steve; Bretz, Sarah

    2003-07-01T23:59:59.000Z

    Roofs that have high solar reflectance (high ability toreflect sunlight) and high thermal emittance (high ability to radiateheat) tend to stay cool in the sun. The same is true of low-emittanceroofs with exceptionally high solar reflectance. Substituting a cool rooffor a non-cool roof tends to decrease cooling electricity use, coolingpower demand, and cooling-equipment capacity requirements, while slightlyincreasing heating energy consumption. Cool roofs can also lower citywideambient air temperature in summer, slowing ozone formation and increasinghuman comfort.DOE-2.1E building energy simulations indicate that use of acool roofing material on a prototypical California nonresidential (NR)building with a low-sloped roof yields average annual cooling energysavings of approximately 3.2 kW h/m2 (300 kW h/1000 ft2), average annualnatural gas deficits of 5.6 MJ/m2 (4.9 therm/1000 ft2), average annualsource energy savings of 30 MJ/m2 (2.6 MBTU/1000 ft2), and average peakpower demand savings of 2.1 W/m2 (0.19 kW/1000 ft2). The 15-year netpresent value (NPV) of energy savings averages $4.90/m2 ($450/1000 ft2)with time-dependent valuation (TDV), and $4.00/m2 ($370/1000 ft2) withoutTDV. When cost savings from downsizing cooling equipment are included,the average total savings (15-year NPV+equipment savings) rises to$5.90/m2 ($550/1000 ft2) with TDV, and to $5.00/m2 ($470/1000 ft2)without TDV.Total savings range from 1.90 to 8.30 $/m2 (0.18 0.77 $/ft2)with TDV, and from 1.70 to 7.10 $/m2 (0.16 0.66 $/ft2) without TDV,across California's 16 climate zones. The typical cost premium for a coolroof is 0.00 2.20 $/m2 (0.00 0.20 $/ft2). Cool roofs with premiums up to$2.20/m2 ($0.20/ft2) are expected to be cost effective in climate zones 216; those with premiums not exceeding $1.90/m2 ($0.18/ft2) are expectedto be also cost effective in climate zone 1. Hence, this study recommendsthat the year-2005 California building energy efficiency code (Title 24,Part 6 of the California Code of Regulations) for NR buildings withlow-sloped roofs include a cool-roof prescriptive requirement in allCalifornia climate zones. Buildings with roofs that do not meetprescriptive requirements may comply with the code via an"overall-envelope" approach (non-metal roofs only), or via a performanceapproach (all roof types).

  8. what is a cool roof? what is the

    E-Print Network [OSTI]

    on materials, climate zone, & electricity rates.1 · Improved occupant comfort · Compliance with building energy Licensing Board for any construction project valued at over $500 in labor and materials. #12;COOL ROOFS 2008 on hot, sunny days. Solar reflectance refers to a material's ability to reflect the sun's solar energy

  9. Preliminary Analysis of Energy Consumption For Cool Roofing Measures

    E-Print Network [OSTI]

    Wang, Xiaorui "Ray"

    decisions by offering design requirements and establishing building codes. Over the last decade, muchPreliminary Analysis of Energy Consumption For Cool Roofing Measures By Joe Mellott, Joshua New to reduce energy demand by reflecting sunlight away from structures and back into the atmosphere. By use

  10. Vegetated Roof Water-Balance Model: Experimental and Model Results

    E-Print Network [OSTI]

    urbanization effects on the water cycle. Although there are many stormwater best management practices (BMPs (ET) and soil media water storage between storm events. Lazzarin et al. (2005) estimated that ET ratesVegetated Roof Water-Balance Model: Experimental and Model Results James A. Sherrard Jr.1

  11. Load test of the 277W Building high bay roof deck and support structure

    SciTech Connect (OSTI)

    McCoy, R.M.

    1994-12-02T23:59:59.000Z

    The 277W Building high bay roof area was load tested according to the approved load-test procedure, WHC-SD-GN-TP-30015, Revision 1. The 277W Building is located in the 200 West Area of the Hanford Site and has the following characteristics: roof deck -- wood decking supported by 4 x 14 timber purlins; roof membrane -- tar and gravel; roof slope -- flat (<10 deg); and roof elevation -- maximum height of about 63 ft. The 227W Building was visited in March 1994 for a visual inspection. During this inspection, cracked areas were visible in the decking, but it was not possible to determine whether these cracks extended completely through the decking, which is 2-in. thick. The building was revisited in March 1994 for the purpose of writing this test report. Because the roof requires personnel access, a test was determined to be the best way to qualify the roof. The conclusions are that the roof has been qualified for 500-lb total roof load and that the ``No Roof Access`` signs can be changed to ``Roof Access Restricted`` signs.

  12. EVALUATION OF ROOF BOLTING REQUIREMENTS BASED ON IN-MINE BOLTER DRILLING

    SciTech Connect (OSTI)

    Syd S. Peng

    2002-07-15T23:59:59.000Z

    Roof bolting is the most popular method for underground openings in the mining industry, especially in the bedded deposits such as coal, potash, salt etc. In fact, all U.S. underground coal mine entries are roof-bolted as required by law. However, roof falls still occur frequently in the roof bolted entries. The two possible reasons are: the lack of knowledge of and technology to detect the roof geological conditions in advance of mining, and lack of roof bolting design criteria for modern roof bolting systems. This research is to develop a method for predicting the roof geology and stability condition in real time during roof bolting operation. Based on such information, roof bolting design criteria for modern roof bolting systems will be developed for implementation in real time. Field tests have been performed in two underground coal mines in this quarter. It also found from the tests that the non-drilling thrust and torque should be deducted from the acquired drilling data. The non-drilling torque is actually higher than that is used to overcome the shear strength is proportional to the rotation rate.

  13. The Equivalent Thermal Resistance of Tile Roofs with and without Batten Systems

    SciTech Connect (OSTI)

    Miller, William A [ORNL] [ORNL

    2013-01-01T23:59:59.000Z

    Clay and concrete tile roofs were installed on a fully instrumented attic test facility operating in East Tennessee s climate. Roof, attic and deck temperatures and heat flows were recorded for each of the tile roofs and also on an adjacent attic cavity covered with a conventionally pigmented and direct-nailed asphalt shingle roof. The data were used to benchmark a computer tool for simulation of roofs and attics and the tool used to develop an approach for computing an equivalent seasonal R-value for sub-tile venting. The approach computed equal heat fluxes through the ceilings of roofs having different combinations of surface radiation properties and or building constructions. A direct nailed shingle roof served as a control for estimating the equivalent thermal resistance of the air space. Simulations were benchmarked to data in the ASHRAE Fundamentals for the thermal resistance of inclined and closed air spaces.

  14. Load test of the 283W Clearwell Roof Deck and Support Structure

    SciTech Connect (OSTI)

    McCoy, R.M.

    1994-09-12T23:59:59.000Z

    The 283W Clearwell roof area was load tested according to the approved load-test procedure, WHC-SD-GN-TP-30015, Revision 0, as modified below. The 283W Clearwell is located in the 200 West Area of the Hanford Site and has the following characteristics: Roof deck - concrete slab supported by columns and walls; Roof membrane - tar and gravel; Roof slope - flat (< 10 deg); and Roof elevation - approximately 6 in. above ground level. The 283W Clearwell was visited in April 1993 for a visual inspection, but could not be inspected because of the confined space requirements. It was revisited in February 1994 for the purpose of writing this test report. Because the roof could not be inspected, a test was determined to be the best way to qualify the roof for personnel access.

  15. Bridgeton Research Center Roof Replacement and Related Work December 4, 2000 DSR # 0029-99 C/D

    E-Print Network [OSTI]

    Bridgeton Research Center Roof Replacement and Related Work December 4, 2000 DSR # 0029-99 C/D SECTION 07220 ­ ROOF INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions: contains requirements for wood blocking to be installed prior to roof insulation. 1. Roof insulation

  16. Perspective-Dependent Color-Changing Roofing Sheets Anthony Cartwright, Joseph Karas, Steven McCarthy, Brian Paige

    E-Print Network [OSTI]

    Rollins, Andrew M.

    on their energy bills. Two primary factors affecting the temperature of roofs have been identified: solar weight to the top of the roof. Many companies also produce highly reflective roof coatings that block solar radiation and can reduce average surface temperatures of the roof up to __ degrees. However

  17. CATALOG OF PROCESSED DATA FOR 7 BUILDINGS A.0466 Los Angeles, 15250 Ventura Blvd., Roof (13th floor) (pp. 7)

    E-Print Network [OSTI]

    Southern California, University of

    APPENDIX A CATALOG OF PROCESSED DATA FOR 7 BUILDINGS A.0466 Los Angeles, 15250 Ventura Blvd., Roof Angeles, 16000 Ventura Blvd., Roof (13th floor) (pp. 13) A.5457 Los Angeles, 8436 West 3rd St., Roof (10th floor) (pp. 19) #12;#12;A.0466--1 Appendix A.0466 LOS ANGELES, 15250 VENTURA BLVD., ROOF (13th Floor

  18. A Study of the Energy-Saving Potential of Metal Roofs Incorporating Dynamic Insulation Systems

    SciTech Connect (OSTI)

    Biswas, Kaushik [ORNL; Miller, William A [ORNL; Kriner, Scott [Metal Construction Association, Glenview, IL; Manlove, Gary [Metanna, Monument, CO

    2013-01-01T23:59:59.000Z

    This article presents various metal roof configurations that were tested at Oak Ridge National Laboratory in Tennessee, U.S. between 2009 and 2013, and describes their potential for reducing the attic-generated space-conditioning loads. These roofs contained different combinations of phase-change material, rigid insulation, low emittance surface, and above-sheathing ventilation with standing-seam metal panels on top. These roofs were designed to be installed on existing roofs decks, or on top of asphalt shingles for retrofit construction. All the tested roofs showed the potential for substantial energy savings compared to an asphalt shingle roof, which was used as a control for comparison. The roofs were constructed on a series of adjacent attics separated at the gables using thick foam insulation. The attics were built on top of a conditioned room. All attics were vented at the soffit and ridge. The test roofs and attics were instrumented with an array of thermocouples. Heat flux transducers were installed in the roof deck and attic floor (ceiling) to measure the heat flows through the roof and between the attic and conditioned space below. Temperature and heat flux data were collected during the heating, cooling and swing seasons over a three-year period. Data from previous years of testing have been published. Here, data from the latest roof configurations being tested in year three of the project are presented. All test roofs were highly effective in reducing the heat flows through the roof and ceiling, and in reducing the diurnal attic-temperature fluctuations.

  19. Thermal Performance Evaluation of Innovative Metal Building Roof Assemblies

    SciTech Connect (OSTI)

    Walker, Daniel James [ORNL; Zaltash, Abdolreza [ORNL; Atchley, Jerald Allen [ORNL

    2011-01-01T23:59:59.000Z

    In order to meet the coming energy codes, multiple layers of various insulation types will be required. The demand for greater efficiency has pushed insulation levels beyond the cavity depth. These experiments show the potential for improving metal building roof thermal performance. Additional work is currently being done by several stakeholders, so the data is expanding. These experiments are for research and development purposes, and may not be viable for immediate use.

  20. Roofing as a Contributor to Urban Runoff Pollution

    E-Print Network [OSTI]

    Clark, Shirley E.

    at: http://www.eng.ua.edu/~rpitt Map courtesy of U.S. Geological Website on Acid Rain #12;2 Roof · Summer 2002: Laboratory TCLP (acid rain simulation) · Fall/Winter 2002 and Spring 2003: Laboratory Testing Set-Up at Penn State Harrisburg During Rain Event, August 2005 pH Rainfall pH Range: 3.9 ­ 6

  1. Theory vs. Practice in Direct Evaporative Roof Spray Cooling

    E-Print Network [OSTI]

    Smith, J. L.; Smith, J. C.

    1985-01-01T23:59:59.000Z

    by sprayheads through varying their orifice sizes and spray angles, by various forms of tempera- ture and climate sensors, and by the controller's sequence control panel. During the installation of the piping system, the roof membrane should.../thermostat mechanism, which typica1.l~ sprayed either too much or too little water. These findings led to the development of a "punched pipe" system. With punched pipe systems, holes are punched or milled into "sticks" of copper or pvc pipe. These holes generally...

  2. Thermal resistance of prototypical cellular plastic roof insulations

    SciTech Connect (OSTI)

    McElroy, D.L.; Graves, R.S.; Weaver, F.J.

    1991-01-01T23:59:59.000Z

    A cooperative industry/government project was initiated in 1989 to evaluate the viability of alternative hydrochlorofluorocarbons (HCFCs) as blowing agents in polyisocyanurate (PIR) boardstock for roofing applications. Five sets of PIR boardstock were produced to industry specifications for current roof insulation technology. The boardstock allowed the performance of four alternative blowing agents (HCFC-123, HCFC-14lb, and two blends of HCFC-123 and HCFC-14lb) to compared to CFC-11. Laboratory and field tests show the relative thermal performance of the individual PIR boards. One set of laboratory tests show the thermal conductivity (k) from 0 to 50{degree}C (30 to 120{degree}F) of boards prior to installation and as a function of time after exposure to field conditions in the Roof Thermal Research Apparatus (0, 9, and 15 months). Another set of laboratory tests show k as a function of aging time 24{degree}C (75{degree}F) and 65{degree}C (150{degree}F) for full-thickness, half-thickness, and quarter-thickness specimens. These test results and modeling calculations show the value of thin specimen testing as an accelerated aging procedure. 24 refs., 5 figs., 7 tabs.

  3. Geologic structures that affect coal-mine roof stability

    SciTech Connect (OSTI)

    Chase, F.E. (Bureau of Mines, Pittsburgh, PA (United States))

    1991-08-01T23:59:59.000Z

    The US Bureau of Mines has investigated several geologic structures that plague underground coal mining. These structures have caused numerous roof falls and, consequently, many miners have been hurt or fatally injured. Hazardous geologic anomalies that can be encountered in the eastern and western US coal fields include slips, hill seams, slickensides, sedimentary dikes, kettlebottoms, and paleochannels. Slips occur throughout the United States and are high-angled fractures in the roof rock. Typically, the rock adjacent to slips is highly slickensided and striated. Hill seams are weathered fracture zones and usually are found in areas where the overburden is shallow. Due to their nature and regional mining conditions, hill seams usually are found only in the southern Appalachian coal basin. Slickensides are lower angled planes of weakness found in coal-mine roof rock throughout the country. Slickensides usually are found in clusters and the adjacent rock is highly polished and striated. Sedimentary dikes (also clastic dikes and clay veins) are the remnants of ancient fissures that have been filled through sedimentary processes, Sedimentary dikes normally are found in coal basins that were slowly subsided. Kettlebottoms are the fossilized remains of trees that once grew in and above the swamp forest and generally are found in coal basins that were rapidly subsided. Paleochannels are the lithified remains of rivers and frequently are found in all coal basins except the Black Warrior.

  4. Equilibrium thermal characteristics of a building integrated photovoltaic tiled roof

    SciTech Connect (OSTI)

    Mei, L.; Gottschalg, R.; Loveday, D.L. [Centre for Renewable Energy Systems Technology (CREST), Department of Electronic and Electrical Engineering, Loughborough University, Loughborough, Leicestershire, LE11 3TU (United Kingdom); Infield, D.G. [Institute of Energy and Environment, Department of Electronic and Electrical Engineering, University of Strathclyde, Glasgow, G1 1XW (United Kingdom); Davies, D.; Berry, M. [Solarcentury, 91-94 Lower Marsh Waterloo, London, SE1 7AB (United Kingdom)

    2009-10-15T23:59:59.000Z

    Photovoltaic (PV) modules attain high temperatures when exposed to a combination of high radiation levels and elevated ambient temperatures. The temperature rise can be particularly problematic for fully building integrated PV (BIPV) roof tile systems if back ventilation is restricted. PV laminates could suffer yield degradation and accelerated aging in these conditions. This paper presents a laboratory based experimental investigation undertaken to determine the potential for high temperature operation in such a BIPV installation. This is achieved by ascertaining the dependence of the PV roof tile temperature on incident radiation and ambient temperature. A theory based correction was developed to account for the unrealistic sky temperature of the solar simulator used in the experiments. The particular PV roof tiles used are warranted up to an operational temperature of 85 C, anything above this temperature will void the warranty because of potential damage to the integrity of the encapsulation. As a guide for installers, a map of southern Europe has been generated indicating locations where excessive module temperatures might be expected and thus where installation is inadvisable. (author)

  5. Comparison of the Perception of Facility Managers on Green Roofs Attributes and Barriers to their Implementation

    E-Print Network [OSTI]

    Ferrer Garcia, Eduardo R

    2014-07-24T23:59:59.000Z

    on Green Roofs Wong et, al (2005) conducted a study on perception of building professionals on the issues of green roofs. The objective of the study was to determine the current perception of building professionals on the issues of green roof... development and any conflicting opinions among them. Wong et, al (2005) used two components for the field study, a self-administered postal survey questionnaire and interviews. The survey was conducted among three target populations, architectural firms...

  6. Illumination of interior spaces by bended hollow light guides: Application of the theoretical light propagation method

    SciTech Connect (OSTI)

    Darula, Stanislav; Kocifaj, Miroslav; Kittler, Richard [ICA, Slovak Academy of Sciences, Bratislava (Slovakia); Kundracik, Frantisek [Department of Experimental Physics, FMPI, Comenius University, Bratislava (Slovakia)

    2010-12-15T23:59:59.000Z

    To ensure comfort and healthy conditions in interior spaces the thermal, acoustics and daylight factors of the environment have to be considered in the building design. Due to effective energy performance in buildings the new technology and applications also in daylight engineering are sought such as tubular light guides. These allow the transport of natural light into the building core reducing energy consumption. A lot of installations with various geometrical and optical properties can be applied in real buildings. The simplest set of tubular light guide consists of a transparent cupola, direct tube with high reflected inner surface and a ceiling cover or diffuser redistributing light into the interior. Such vertical tubular guide is often used on flat roofs. When the roof construction is inclined a bend in the light guide system has to be installed. In this case the cupola is set on the sloped roof which collects sunlight and skylight from the seen part of the sky hemisphere as well as that reflected from the ground and opposite facades. In comparison with the vertical tube some additional light losses and distortions of the propagated light have to be expected in bended tubular light guides. Recently the theoretical model of light propagation was already published and its applications are presented in this study solving illuminance distributions on the ceiling cover interface and further illuminance distribution on the working plane in the interior. (author)

  7. Reflections on Cambridge: Inside the roof of King's College Chapel - 2009

    E-Print Network [OSTI]

    Macfarlane, Alan

    Alan Macfarlane, a Fellow of King's College, Cambridge, visits the roof above the famous Chapel and explains some of its features. Filmed in summer 2009 by Xu Bei....

  8. D0 Silicon Upgrade: Upgrade Piping Loads on Cleanroom Roof

    SciTech Connect (OSTI)

    Sakla, Steve; /Fermilab

    1995-08-28T23:59:59.000Z

    The proposed piping layout for the DO upgrade will run along the south wall of DAB. The cryogenic service pipe runs above the upper and lower cleanroom roofs and will need to be supported by the roofs beams. Calculations were done to determine the stresses in the I-beams created by the existing and additional loads due to the upgrade. Refer to drawing no. 3823.115-ME-317283 for drawings of the piping layout. Figure 1 shows the 'plan view' portion of this drawing. The weight of the individual lines were calculated in figure 2 assuming a pipe density of O.28 lbm/in{sup 3} for stainless steel (0.12% C) and a fluid density (assuming LN2 at 1 atm) of 0.03 lbm/in{sup 3}. The weights of the corrugated steel flooring, assembly hall feed cans, support beams, and roof hatch were also included in the analysis. These loads are calculated on pgs. 5-6. A floor load of 50 lbf/ft{sup 2} was also added in order to maintain the existing floor load limit in addition to the added piping loads. Measurements of the dimensions of the I-beams determined that the nominal sizes of the beams were W8 x 21 for the lower roof and W14 x 26 for the upper roof. Pipe lengths were determined from the drawing for each of the lines on pgs. 1-2 of the calculations (refer to all piping by line numbers according to figure 2). A total weight was calculated for lines 3-9 along the south wall and lines 1-2 running along the north wall of the lower cleanroom roof. To simplify the calculations these weights were assumed to be evenly distributed on the 5 I-beam supports of the lower cleanroom roof 2.5 feet in from the south wall. The stress analysis was done using FrameMac, a 2-D finite element program for the Macintosh. Beam 3 was not included in the analysis because it is structurally equivalent to beam 1. The program outputted maximum values for shear stress, bending stress, shear force, and moments in each of the beams analyzed. These values were then compared to the allowable stresses as per the specifications and codes stated in the AISC: Manual of Steel Construction. The stresses on the roof beams needed to be determined in a number of different places. The first was in the beam itself which included the flange and web sections. The second place was at the ends of the beams where the flanges were removed to make the perpendicular connections to the other beams on the lower roof. The final point was the framed beam connection which included the bolt analysis. FrameMac calculated stresses only for the beams which included the sections where the flanges were removed to make the end connections. To analyze the connections, the allowable bending and shear stresses were solved for allowable shear and moments. This was done because FrameMac does not have the capability to analyze the dimensions for the bolts and angles used in the connections were known and the program outputted values for reaction forces and moments at the ends of the beams. Multiplying the allowable shear stress for the bolts and angle connections by their respective areas gave the allowable shear force. The allowable moment for the angle connection was calculated by multiplying the section modulus of the angle by the allowable bending stress. These allowable loads are calculated on pgs. 7-8. The allowable and maximum calculated stresses by FrameMac are summarized in a table. In conclusion, the cleanroom roofs will be able to safely support the weight of the upgrade cryogenic piping, feed cans, corrugated flooring and a 50 lbf/ft{sup 2} floor load with the addition of diagonal braces at the ends of beams 1,2,3,4, and 8. The location and size of these diagonal braces are shown in fig. 4. Also, the piping supports and feed cans will all need to be placed directly above the I-beam supports. These supports will consist of unistrut structures that will be detailed and specified separate to this analysis. The output and input data from FrameMac and the drawings used in the analysis follow the calculation pages.

  9. Using Cool Roofs to Reduce Energy Use, Greenhouse Gas Emissions, and Urban Heat-island Effects: Findings from an India Experiment

    E-Print Network [OSTI]

    Akbari, Hashem

    2011-01-01T23:59:59.000Z

    49 Figure 26. Comparison of roof heat flux for East and West49 Figure 27. Roof heat flux vs. outside air temperature for8-19. 50 Figure 28. Roof heat flux vs. outside air

  10. Asphalt Roofing Shingles Into Energy Project Summary Report

    SciTech Connect (OSTI)

    Jameson, Rex, PE

    2008-04-28T23:59:59.000Z

    Based on a widely cited September, 1999 report by the Vermont Agency of Natural Resources, nearly 11 million tons of asphalt roofing shingle wastes are produced in the United States each year. Recent data suggests that the total is made up of about 9.4 million tons from roofing tear-offs and about 1.6 million tons from manufacturing scrap. Developing beneficial uses for these materials would conserve natural resources, promote protection of the environment and strengthen the economy. This project explored the feasibility of using chipped asphalt shingle materials in cement manufacturing kilns and circulating fluidized bed (CFB) boilers. A method of enhancing the value of chipped shingle materials for use as fuel by removing certain fractions for use as substitute raw materials for the manufacture of new shingles was also explored. Procedures were developed to prevent asbestos containing materials from being processed at the chipping facilities, and the frequency of the occurrence of asbestos in residential roofing tear-off materials was evaluated. The economic feasibility of each potential use was evaluated based on experience gained during the project and on a review of the well established use of shingle materials in hot mix asphalt. This project demonstrated that chipped asphalt shingle materials can be suitable for use as fuel in circulating fluidized boilers and cement kilns. More experience would be necessary to determine the full benefits that could be derived and to discover long term effects, but no technical barriers to full scale commercial use of chipped asphalt shingle materials in these applications were discovered. While the technical feasibility of various options was demonstrated, only the use of asphalt shingle materials in hot mix asphalt applications is currently viable economically.

  11. Attic or Roof? An Evaluation of Two Advanced Weatherization Packages

    SciTech Connect (OSTI)

    Neuhauser, K.

    2012-06-01T23:59:59.000Z

    This project examines implementation of advanced retrofit measures in the context of a large-scale weatherization program and the archetypal Chicago brick bungalow. One strategy applies best practice air sealing methods and a standard insulation method to the attic floor. The other strategy creates an unvented roof assembly using materials and methods typically available to weatherization contractors. Through implementations of the retrofit strategies in a total of eight (8) test homes, the research found that the two different strategies achieve similar reductions in air leakage measurement (55%) and predicted energy performance (18%) relative to the pre-retrofit conditions.

  12. Cool Roofs: An Easy Upgrade | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 1112011AT&T, Inc.'sEnergyTexas1.SpaceFluorControls andCONVENTIONAL ENERGY|Cool Roofs: An

  13. Covered Product Category: Cool Roof Products | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: Theof"Wave theJuly 30, 2013Department ofU.S.forCategoriesDepartmentCool Roof

  14. Urban Heat Islands: Cool Roof Infrastructure | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33Frequently20,000 Russian Nuclear Warheads intoMansoor Ghassem )DepartmentUppingDepartmentCool Roof

  15. Developing Energy Efficient Roof Systems DEERS | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnual Siteof Energy 2,AUDIT REPORTEnergy OffshoreDeveloper - Q & A Home >Roof Systems

  16. Cool Roofs and Heat Islands | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnualProperty EditCalifornia:PowerCER.pngRoofs and Heat Islands Jump to: navigation, search Tool

  17. New Cool Roof Coatings and Affordable Cool Color Asphalt

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn'tOrigin of Contamination in Many DevilsForum |EnergyNew Catalytic ConversionNew Cool Roof

  18. Next Generation Attics and Roof Systems | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreaking ofOilNEW HAMPSHIREofNewsletter Newsletter Better BuildingsAttics and Roof

  19. Neuron, Vol. 24, 127141, September, 1999, Copyright 1999 by Cell Press BMPs as Mediators of Roof Plate Repulsion

    E-Print Network [OSTI]

    Butler, Samantha

    Neuron, Vol. 24, 127­141, September, 1999, Copyright ©1999 by Cell Press BMPs as Mediators of Roof., 1997). that the roof plate (RP) expresses a diffusible activity One source of FP-independent guidance

  20. Library of Science & Medicine Roof Replacement and Related Work Dec. 11, 2000 DSR # 0059-00 BSH

    E-Print Network [OSTI]

    Library of Science & Medicine Roof Replacement and Related Work Dec. 11, 2000 DSR # 0059-00 BSH AFFIDAVIT OF NON-USE OF ASBESTOS Project: Roof Replacement and Related Work at LIBRARY OF SCIENCE & MEDICINE

  1. Digging the New York City Skyline: Soil Fungal Communities in Green Roofs and City Parks

    E-Print Network [OSTI]

    Fierer, Noah

    microbes across the greater New York City area is locally variable. Green roof fungal communities wereDigging the New York City Skyline: Soil Fungal Communities in Green Roofs and City Parks Krista L a number of benefits, including decreased urban heat island effects and reduced energy costs for buildings

  2. Roof Replacement and Related Work February 17, 2000 DSR # 0000-00 XXX

    E-Print Network [OSTI]

    Roof Replacement and Related Work February 17, 2000 DSR # 0000-00 XXX SECTION 02071 - REMOVAL # 0000-00 XXX A. Removal and disposal shall be performed in accordance with ap- plicable State 02071 - 2 (Rev. 9/00) #12;Roof Replacement and Related Work February 17, 2000 DSR # 0000-00 XXX 1

  3. Reduced Energy and Maintenance Costs Using Polyurethane as a Replacement Roof System

    E-Print Network [OSTI]

    Scott, G. D.

    failures had occurred and resealing and reflashing penetrations. In many instances roof crews were unable to accomplish a permanent fix without a major tear-off and replacement of the existing roof. 40 ESL-HH-92-05-08 Proceedings of the Eighth...

  4. Sensitivity of Low Sloped Roofs Designs to Initial Water and Air Leakage

    E-Print Network [OSTI]

    Karagiozis, A.; Desjarlais, A.; Salonvaara, M.

    2002-01-01T23:59:59.000Z

    moisture to the outside. Solar radiation raises the temperature of air in the grooves and on average, during a sunny summer day 0.5 L of water can be ventilated out of the roof per 1m width of the roof. In this paper, one climatic condition was investigated...

  5. Roof Integrated Solar Absorbers: The Measured Performance of ''Invisible'' Solar Collectors: Preprint

    SciTech Connect (OSTI)

    Colon, C. J. (Florida Solar Energy Center); Merrigan, T. (National Renewable Energy Laboratory)

    2001-10-19T23:59:59.000Z

    The Florida Solar Energy Center (FSEC), with the support of the National Renewable Energy Laboratory, has investigated the thermal performance of solar absorbers that are an integral, yet indistinguishable, part of a building's roof. The first roof-integrated solar absorber (RISA) system was retrofitted into FSEC's Flexible Roof Facility in Cocoa, Florida, in September 1998. This ''proof-of-concept'' system uses the asphalt shingle roof surface and the plywood decking under the shingles as an unglazed solar absorber. Data was gathered for a one-year period on the system performance. In Phase 2, two more RISA prototypes were constructed and submitted for testing. The first used the asphalt shingles on the roof surface with the tubing mounted on the underside of the plywood decking. The second prototype used metal roofing panels over a plywood substrate and placed the polymer tubing between the plywood decking and the metal roofing. This paper takes a first look at the thermal performance results for the ''invisible'' solar absorbers that use the actual roof surface of a building for solar heat collection.

  6. Comparative Summer Thermal Performance of Finished and Unfinished Metal Roofing Products with Composition Shingles

    E-Print Network [OSTI]

    Parker, D. S.; Sherwin, J.; Sonne, J.

    2004-01-01T23:59:59.000Z

    , both finished and unfinished, might compare with other more traditional roofing types. All of the test cells had R-19 insulation installed on the attic floor except in the double roof configuration which had R-19 of open cell foam blown onto...

  7. Proposal for the award of a contract for the civil engineering work relating to the roof renovation of Building 867

    E-Print Network [OSTI]

    2011-01-01T23:59:59.000Z

    Proposal for the award of a contract for the civil engineering work relating to the roof renovation of Building 867

  8. CAVERN ROOF STABILITY FOR NATURAL GAS STORAGE IN BEDDED SALT

    SciTech Connect (OSTI)

    DeVries, Kerry L; Mellegard, Kirby D; Callahan, Gary D; Goodman, William M

    2005-06-01T23:59:59.000Z

    This report documents research performed to develop a new stress-based criterion for predicting the onset of damage in salt formations surrounding natural gas storage caverns. Laboratory tests were conducted to investigate the effects of shear stress, mean stress, pore pressure, temperature, and Lode angle on the strength and creep characteristics of salt. The laboratory test data were used in the development of the new criterion. The laboratory results indicate that the strength of salt strongly depends on the mean stress and Lode angle. The strength of the salt does not appear to be sensitive to temperature. Pore pressure effects were not readily apparent until a significant level of damage was induced and the permeability was increased to allow penetration of the liquid permeant. Utilizing the new criterion, numerical simulations were used to estimate the minimum allowable gas pressure for hypothetical storage caverns located in a bedded salt formation. The simulations performed illustrate the influence that cavern roof span, depth, roof salt thickness, shale thickness, and shale stiffness have on the allowable operating pressure range. Interestingly, comparison of predictions using the new criterion with that of a commonly used criterion indicate that lower minimum gas pressures may be allowed for caverns at shallow depths. However, as cavern depth is increased, less conservative estimates for minimum gas pressure were determined by the new criterion.

  9. Numerical evaluation of the thermal performances of roof-mounted radiant barriers

    E-Print Network [OSTI]

    Miranville, Frédéric; Lucas, Franck; Johan, Seriacaroupin

    2014-01-01T23:59:59.000Z

    This paper deals with the thermal performances of roof-mounted radiant barriers. Using dynamic simulations of a mathematical model of a whole test cell including a radiant barrier installed between the roof top and the ceiling, the thermal performance of the roof is calculated. The mean method is more particularly used to assess the thermal resistance of the building component and lead to a value which is compared to the one obtained for a mass insulation product such as polyurethane foam. On a further stage, the thermal mathematical model is replaced by a thermo-aeraulic model which is used to evaluate the thermal resistance of the roof as a function of the airflow rate. The results shows a better performance of the roof in this new configuration, which is widely used in practice. Finally, the mathematical relation between the thermal resistance and the airflow rate is proposed.

  10. A guidebook for insulated low-slope roof systems. IEA Annex 19, Low-slope roof systems: International Energy Agency Energy Conservation in Buildings and Community Systems Programme

    SciTech Connect (OSTI)

    Not Available

    1994-02-01T23:59:59.000Z

    Low-slope roof systems are common on commercial and industrial buildings and, to a lesser extent, on residential buildings. Although insulating materials have nearly always been a component of low-slope roofs, the amount of insulation used has increased in the past two decades because of escalation of heating and cooling costs and increased awareness of the need for energy conservation. As the amount of insulation has increased, the demand has intensified for design, installation, and maintenance information specifically for well-insulated roofs. Existing practices for design, installation, and maintenance of insulated roofs have evolved from experience. Typically, these practices feature compromises due to the different properties of materials making up a given roof system. Therefore, they should be examined from time to time to ensure that they are appropriate as new materials continue to enter the market and as the data base on existing systems expands. A primary purpose of this International Energy Agency (IEA) study is to assess current roofing insulation practices in the context of an accumulating data base on performance.

  11. Quantifying air pollution removal by green roofs in Chicago Jun Yang a,c,*, Qian Yu b

    E-Print Network [OSTI]

    Yu, Qian

    Quantifying air pollution removal by green roofs in Chicago Jun Yang a,c,*, Qian Yu b , Peng Gong c t The level of air pollution removal by green roofs in Chicago was quantified using a dry deposition model. The result showed that a total of 1675 kg of air pollutants was removed by 19.8 ha of green roofs in one year

  12. 24897Federal Register / Vol. 62, No. 88 / Wednesday, May 7, 1997 / Proposed Rules 1 Petition for review pending, GS Roofing

    E-Print Network [OSTI]

    for review pending, GS Roofing Products Company, Inc., et al. v. Surface Transportation Board, No. 97­107 (8: In a decision in GS Roofing Products Company, Inc., Beazer West, Inc., D/B/ A Gifford Hill & Company, Bean., Docket No. 41230 (STB served Mar. 11, 1997) (GS Roofing), 1 we reviewed a fact- specific complaint

  13. HOUGH-TRANSFORM AND EXTENDED RANSAC ALGORITHMS FOR AUTOMATIC DETECTION OF 3D BUILDING ROOF PLANES FROM LIDAR DATA

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    HOUGH-TRANSFORM AND EXTENDED RANSAC ALGORITHMS FOR AUTOMATIC DETECTION OF 3D BUILDING ROOF PLANES reconstruction methods, the techniques allowing the detection of 3D building roof planes are of crucial even if this plane does not always represent a roof plane. So the proposed extension allows harmonizing

  14. A new method for modelling roofing materials emissions on the city scale: Application for zinc in the city of Crteil

    E-Print Network [OSTI]

    Boyer, Edmond

    1 A new method for modelling roofing materials emissions on the city scale: Application for zinc as an important source of environmental pollution. Roofing materials, in particular the metallic ones Directive (2000/60 CE), an accurate evaluation of contaminant flows from roofs is thus required on the city

  15. Assessment of technologies for constructing self-drying low-slope roofs

    SciTech Connect (OSTI)

    Kyle, D.M.; Desjarlais, A.O.

    1994-05-01T23:59:59.000Z

    Issues associated with removing excessive moisture from low-slope roofs have been assessed. The economic costs associated with moisture trapped in existing roofs have been estimated. The evidence suggests that existing moisture levels cause approximately a 40% overall reduction in the R-value of installed roofing insulation in the United States. Excess operating costs are further increased by a summertime heat transfer mode unique to wet insulation, caused by the daily migration of water within the roof. By itself, this effect can increase peak electrical demand for air conditioning by roughly 15 W/m{sup 2} of roofing, depending on the type of insulation. This effect will increase peak demand capacity required of utilities in any geographic region (e.g., 900 MW in the South). A simple formula has been derived for predicting the effect that self-drying roofs can have upon time-averaged construction costs. It is presumed that time-averaged costs depend predominantly upon (1) actual service life and (2) the likelihood that the less expensive recover membranes can be installed safely over old roofs. For example, an increase in service life from 15 to 20 years should reduce the current cost of roofing ($12 billion/year) by 21%. Another simple formula for predicting the reroofing waste volume indicates that an increase in service life from 15 to 20 years might reduce the current estimated 0.4 billion ft{sup 3}/year of waste by 25%. A finite-difference computer program has been used to study the flow of heat and moisture within typical existing roofs for a variety of US climates. Nearly all publicly available experimental drying data have been consulted. The drying times for most existing low-slope roofs in the United States are controlled largely climate and the permeability of the structural deck to water vapor.

  16. Use of roof temperature modeling to predict necessary conditions for locating wet insulation with infrared thermography

    SciTech Connect (OSTI)

    Childs, K.W.

    1985-11-01T23:59:59.000Z

    In low-sloped roofing systems using porous insulation, the presence of water can significantly degrade thermal performance. For this reason, it is desirable to develop a reliable method for detecting the presence of water in a roofing system. Because of the different thermal characteristics of wet and dry insulation, there is often a surface temperature differential between areas containing wet insulation and areas containing dry insulation. Under the right circumstances, the areas of wet insulation can be detected by means of infrared sensing techniques. These techniques have already gained widespread acceptance, but there is still some uncertainty as to what are appropriate environmental conditions for viewing. To better define the conditions under which infrared techniques can distinguish between areas of wet and dry insulation, a one-dimensional, transient heat transfer model of a roofing system was developed. The model considers conduction through the roof, insolation on the surface, radiant exchange between the roof and sky, convective heat transfer between the roof and air, and the influence of trapped moisture on the thermal properties of the insulation. A study was undertaken using this model to develop an easily-applied technique for prediction of necessary conditions for locating wet roof insulation using infrared thermography.

  17. Investigation of factors influencing infrared roof moisture surveys using a mathematical model

    SciTech Connect (OSTI)

    Childs, K.W.; Courville, G.E.; Childs, P.W.

    1983-01-01T23:59:59.000Z

    In low sloped roofing systems using porous insulation, the presence of water can significantly degrade thermal performance. Because of the different thermal characteristics of wet and dry insulation, there is often a surface temperature differential between areas of wet and dry insulation. Under the right circumstances, the areas of wet insulation can be detected by means of infrared sensing techniques. To better define the conditions under which infrared techniques can distinguish between areas of wet and dry insulation, a mathematical model was developed. This model is a one-dimensional, transient heat transfer model of a roofing system. The model considers conduction through the roof, insolation, radiant exchange between roof and sky, convective heat transfer between the roof and air, and the influence of moisture trapped in insulation. For one particular roof system, a parametric study was undertaken using this model to determine the influence of moisture content, outside air temperature, wind speed, insolation, sky temperature, and other factors on the roof surface temperature. Preliminary recommendations for employing thermal sensing techniques to locate wet insulation are developed.

  18. Investigation of factors influencing infrared roof moisture surveys using a mathematical model

    SciTech Connect (OSTI)

    Childs, K.W.; Courville, G.E.; Childs, P.W.

    1984-01-01T23:59:59.000Z

    In low sloped roofing systems using porous insulation, the presence of water can significantly degrade thermal performance. Because of the different thermal characteristics of wet and dry insulation, there is often a surface temperature differential between areas of wet and dry insulation. Under the right circumstances, the areas of wet insulation can be detected by means of infrared sensing techniques. To better define the conditions under which infrared techniques can distinguish between areas of wet and dry insulation, a mathematical model was developed. This model is a one-dimensional, transient heat transfer model of a roofing system. The model considers conduction through the roof, insulation, radiant exchange between roof and sky, convective heat transfer between the roof and air, and the influence of moisture trapped in insulation. For one particular roof system, a parametric study was undertaken using this model to determine the influence of moisture content, outside air temperature, wind speed, insulation, sky temperature, and other factors on the roof surface temperature. Preliminary recommendations for employing thermal sensing techniques to locate wet insulation are developed. 11 references, 12 figures.

  19. Quantum Fisher Information as the Convex Roof of Variance

    E-Print Network [OSTI]

    Sixia Yu

    2013-02-21T23:59:59.000Z

    Quantum Fisher information places the fundamental limit to the accuracy of estimating an unknown parameter. Here we shall provide the quantum Fisher information an operational meaning: a mixed state can be so prepared that a given observable has the minimal averaged variance, which equals exactly to the quantum Fisher information for estimating an unknown parameter generated by the unitary dynamics with the given observable as Hamiltonian. In particular we shall prove that the quantum Fisher information is the convex roof of the variance, as conjectured by Toth and Petz based on numerical and analytical evidences, by constructing explicitly a pure-state ensemble of the given mixed state in which the averaged variance of a given observable equals to the quantum Fisher information.

  20. Application of Spray Foam Insulation Under Plywood and Oriented Strand Board Roof Sheathing

    SciTech Connect (OSTI)

    Grin, A.; Smegal, J.; Lstiburek, J.

    2013-10-01T23:59:59.000Z

    Unvented roof strategies with open cell and closed cell spray polyurethane foam insulation sprayed to the underside of roof sheathing have been used since the mid-1990's to provide durable and efficient building enclosures. However, there have been isolated moisture related incidents reported anecdotally that raise potential concerns about the overall hygrothermal performance of these systems. The incidents related to rainwater leakage and condensation concerns. Condensation concerns have been extensively studied by others and are not further discussed in this report. This project involved hygrothermal modeling of a range of rainwater leakage and field evaluations of in-service residential roofs using spray foam insulation. All of the roof assemblies modeled exhibited drying capacity to handle minor rainwater leakage. All field evaluation locations of in-service residential roofs had moisture contents well within the safe range for wood-based sheathing. Explorations of eleven in-service roof systems were completed. The exploration involved taking a sample of spray foam from the underside of the roof sheathing, exposing the sheathing, then taking a moisture content reading. All locations had moisture contents well within the safe range for wood-based sheathing. One full-roof failure was reviewed, as an industry partner was involved with replacing structurally failed roof sheathing. In this case the manufacturer's investigation report concluded that the spray foam was installed on wet OSB based on the observation that the spray foam did not adhere well to the substrate and the pore structure of the closed cell spray foam at the ccSPF/OSB interface was indicative of a wet substrate.

  1. The Effects of Infrared-Blocking Pigments and Deck Venting on Stone-Coated Metal Residential Roofs

    SciTech Connect (OSTI)

    Miller, William A [ORNL

    2006-01-01T23:59:59.000Z

    Field data show that stone-coated metal shakes and S-mission tile, which exploit the use of infraredblocking color pigments (IrBCPs), along with underside venting reduce the heat flow penetrating the conditioned space of a residence by 70% compared with the amount of heat flow penetrating roofs with conventional asphalt shingles. Stone-coated metal roof products are typically placed on battens and counter-battens and nailed through the battens to the roof deck. The design provides venting on the underside of the metal roof that reduces the heat flow penetrating a home. The Metal Construction Association (MCA) and its affiliate members installed stone-coated metal roofs with shake and S-mission tile profiles and a painted metal shake roof on a fully instrumented attic test assembly at Oak Ridge National Laboratory (ORNL). Measurements of roof, deck, attic, and ceiling temperatures; heat flows; solar reflectance; thermal emittance; and ambient weather were recorded for each of the test roofs and also for an adjacent attic cavity covered with a conventional pigmented and direct nailed asphalt shingle roof. All attic assemblies had ridge and soffit venting; the ridge was open to the underside of the stone-coated metal roofs. A control assembly with a conventional asphalt shingle roof was used for comparing deck and ceiling heat transfer rates.

  2. Validation of the thermal effect of roof with the Spraying and green plants in an insulated building

    SciTech Connect (OSTI)

    Zhou, Nan; Gao, Weijun; Nishida, Masaru; Ojima, Toshio

    2004-08-08T23:59:59.000Z

    In recent years, roof-spraying and rooftop lawns have proven effective on roofs with poor thermal insulation. However, the roofs of most buildings have insulating material to provide thermal insulation during the winter. The effects of insulation has not previously been quantified. In this study, the authors collected measurements of an insulated building to quantify the thermal effects of roof-spraying and rooftop lawns. Roof-spraying did not significantly reduce cooling loads and required significant amounts of water. The conclusion is that roof spraying is not suitable for buildings with well-insulated roofs. Rooftop lawns, however, significantly stabilized the indoor temperature while additionally helping to mitigate the heat island phenomenon.

  3. Fatal accidents involving roof falls in coal mining, 1996--1998

    SciTech Connect (OSTI)

    Not Available

    1999-01-01T23:59:59.000Z

    This publication presents information on fatalities involving roof and rib falls that occurred in coal mining operations from January 1996 through December 1998. It includes statistics for the fatalities, as well as abstracts, best practices and illustrations. Conclusion statements have been substituted for best practices where no Title 30 Code of Regulations violations were cited during the accident investigation. From January 1996 through December 1998, 36 miners died at coal operations from accidents classified as roof falls. The information in the report is based on statistics taken from the 1996 through 1998 MSHA Fatal Illustration Programs: Roof Fall Fatalities by District.

  4. Fatal accidents involving roof falls in coal mining, 1996--1998

    SciTech Connect (OSTI)

    NONE

    1999-11-01T23:59:59.000Z

    This publication presents information on fatalities involving roof and rib falls that occurred in coal mining operations from January 1996 through December 1998. It includes statistics for the fatalities, as well as abstracts, best practices and illustrations. Conclusion statements have been substituted for best practices where no Title 30 Code of Regulations violations were cited during the accident investigation. From January 1996 through December 1998, 36 miners died at coal operations from accidents classified as roof falls. The information in the report is based on statistics taken from the 1996 through 1998 MSHA Fatal Illustration Programs: Roof Fall Fatalities by District.

  5. National Synchrotron Light Source II Project Progress Report

    E-Print Network [OSTI]

    Ohta, Shigemi

    in September. Accelerator Systems progress continued with successful procurement and delivery of major. 25 ASD Secondary Cooling System Design Review Sept. 1­2 RF Bellows and Absorbers Review Sept. 8National Synchrotron Light Source II Project Progress Report July 2010 July 30: Roof surfacing

  6. Improving the System Life of Basic Oxygen and Electric Arc Furnace Hoods, Roofs, and Side Vents

    Broader source: Energy.gov [DOE]

    This factsheet describes the benefits of a high-performance aluminum bronze alloy to basic oxygen furnace and electric arc furnace components such as hoods, roofs, and side vents.

  7. Green Roof Water Harvesting and Recycling Effects on Soil and Water Chemistry and Plant Physiology

    E-Print Network [OSTI]

    Laminack, Kirk Dickison

    2014-04-17T23:59:59.000Z

    pressures put on fresh water supplies in urban ecosystems. Alternative irrigation sources can include grey water, sewage effluent (black water) and harvested rainwater which can be a) water captured from an impervious roof and b) stormwater captured from...

  8. INSTALLATION CERTIFICATE CF-6R-ENV-01 Envelope Insulation; Roofing; Fenestration (Page 1 of 3)

    E-Print Network [OSTI]

    INSTALLATION CERTIFICATE CF-6R-ENV-01 Envelope ­ Insulation; Roofing; Fenestration (Page 1 of 3:__________________________________ Brand Name:_______________________________ Thickness (inches):_________________________ Thermal:_______________________________ Thickness (inches):_________________________ Thermal Resistance (R-Value):_________________ Perimeter

  9. Determination of immediate roof at mines of the Kutahya-Omerler coal basin, Turkey

    SciTech Connect (OSTI)

    G. Konak; T. Onargan; C.O. Aksoy; H. Kose; C. Tatar; C. Pamukcu [Dokuz Eylul University, Izmir (Turkey). Department of Mining Engineering

    2006-01-15T23:59:59.000Z

    The estimation of the relations between excavation height, longwall advance rate, convergence around a longwall in the roof-soil direction, and load distribution on support is reported, that are of specific importance for selecting support type. The principal attention is focused on determination of the immediate roof height that depends on the mobility characteristics of overlying rocks and governs mainly the stopping convergence and load intensity on the support. Numerical modeling, laboratory and field experiments are undertaken in this study, which included evaluation of composition and physicomechanical properties of rocks, assessment of stress-strain state of rock mass and of the immediate roof height, measurements of disintegration and bulking factor of overlying rocks, convergence of stopping floor and roof, and loads on hydraulic legs of supports. The study parameters obtained by different methods for the Omerler Mine are presented.

  10. Income Tax Deduction for Solar-Powered Roof Vents or Fans

    Broader source: Energy.gov [DOE]

    Indiana allows taxpayers to take a deduction on solar-powered roof fans (or vent, also sometimes called an attic fan) installed in a home that the taxpayer owns or leases. The deduction is for 50%...

  11. Reflections on Cambridge: Cambridge University from the roof of King's College Chapel - 2009

    E-Print Network [OSTI]

    Macfarlane, Alan

    Film taken from the roof of the famous chapel, with Alan Macfarlane a Fellow of the College explaining a few of the sights. Filmed in summer 2009 by Xu Bei....

  12. Preservation of early wrought iron trusses : the 1848 roof of the Cochituate gatehouse

    E-Print Network [OSTI]

    Ferriss, Lori (Lori E.)

    2009-01-01T23:59:59.000Z

    This thesis investigates the historic significance, structural condition, and preservation challenges of the wrought iron roof trusses of the Cochituate aqueduct's inlet gatehouse as the possible earliest surviving example ...

  13. Sustainable Roofscapes: Developing a green roof implementation model for Tucson, AZ

    E-Print Network [OSTI]

    Fay, Noah

    Sustainable Roofscapes: Developing a green roof implementation model for Tucson, AZ BRENT JACOBSEN Advisor: Dr. Margaret Livingston School of Landscape Architecture and Planning College of Architecture and Landscape Architecture Special Acknowledgements: The University of Arizona, Technology and Research

  14. TASK 2.5.7 FIELD EXPERIMENTS TO EVALUATE COOL-COLORED ROOFING

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    ) demonstrated that white barrel and white flat tiles reduced cooling energy consumption by 22% of the base load the exterior face of the roof sheathing and the underside of the tile. The greater the tile's profile

  15. The Trade-off between Solar Reflectance and Above-Sheathing Ventilation for Metal Roofs on Residential and Commercial Buildings

    SciTech Connect (OSTI)

    Desjarlais, Andre Omer [ORNL] [ORNL; Kriner, Scott [Metal Construction Association, Glenview, IL] [Metal Construction Association, Glenview, IL; Miller, William A [ORNL] [ORNL

    2013-01-01T23:59:59.000Z

    An alternative to white and cool-color roofs that meets prescriptive requirements for steep-slope (residential and non-residential) and low-slope (non-residential) roofing has been documented. Roofs fitted with an inclined air space above the sheathing (herein termed above-sheathing ventilation, or ASV), performed as well as if not better than high-reflectance, high-emittance roofs fastened directly to the deck. Field measurements demonstrated the benefit of roofs designed with ASV. A computer tool was benchmarked against the field data. Testing and benchmarks were conducted at roofs inclined at 18.34 ; the roof span from soffit to ridge was 18.7 ft (5.7 m). The tool was then exercised to compute the solar reflectance needed by a roof equipped with ASV to exhibit the same annual cooling load as that for a direct-to-deck cool-color roof. A painted metal roof with an air space height of 0.75 in. (0.019 m) and spanning 18.7 ft (5.7 m) up the roof incline of 18.34 needed only a 0.10 solar reflectance to exhibit the same annual cooling load as a direct-to-deck cool-color metal roof (solar reflectance of 0.25). This held for all eight ASHRAE climate zones complying with ASHRAE 90.1 (2007a). A dark heat-absorbing roof fitted with 1.5 in. (0.038 m) air space spanning 18.7 ft (5.7 m) and inclined at 18.34 was shown to have a seasonal cooling load equivalent to that of a conventional direct-to-deck cool-color metal roof. Computations for retrofit application based on ASHRAE 90.1 (1980) showed that ASV air spaces of either 0.75 or 1.5 in. (0.019 and 0.038 m) would permit black roofs to have annual cooling loads equivalent to the direct-to-deck cool roof. Results are encouraging, and a parametric study of roof slope and ASV aspect ratio is needed for developing guidelines applicable to all steep- and low-slope roof applications.

  16. Steam System Forecasting and Management 

    E-Print Network [OSTI]

    Mongrue, D. M.; Wittke, D. O.

    1982-01-01T23:59:59.000Z

    process unit is not operating (down) is specified. If the process will be operating for the entire period, the word "LP" is displayed. PRODUCTION SCHEDULE 2/20/92 - 5/20/82 UNIT 1 A UP 2 B UP D 2./20-3./15 D 4.19. TO- 3 C D 2./20-3./15 D 4..../9. TO- 4 D 5 E D 4./15 TO- UP 6 F D 2./20-2./21 7 G UP 9 I UP 8 H D 2./20-3./13 D 3./27 TO- 10 J 11 K D 2./20 TO- 12 L UP 13 M UP UP 15 0 14 N UP D 2./20-2./24 D 3./7.-3./17 D 3./28 TO- 16 P 17 G D 4./1. TO- 19 R II 3...

  17. Laboratory measurements of the drying rates of low-slope roofing systems

    SciTech Connect (OSTI)

    Desjarlais, A.O.; Kyle, D.M.; Childs, P.W.; Christian, J.E.

    1994-05-01T23:59:59.000Z

    The service life of a roofing system typically ends when excessive amounts of water have entered the system. Roofing professionals determine whether the existing failed roofing system can be repaired or salvaged by recovering. A key element in this decision is whether the accumulated water will be able to leave the roofing system in a time frame that will prevent irreparable structural damage. There are several combined heat and mass transfer models that can be used to predict drying times for low-slope roofing systems. Very little experimental data exists that can be used to validate the performance of these models. To satisfy these needs, a series of laboratory experiments has been performed. Five test panels, comprised of a plywood deck, four types of roofing insulation, and a single ply membrane were installed in a climate simulator. The test panels were outfitted with temperature sensors and heat flux transducers, and were mounted on load cells. Water was added to the test panels and they were subjected to external diurnal cycles representative of summer and winter conditions for a southern US continental climate. The load cells supplied continuous records of the weights of the test panels; these data were used to compute the drying rates of the test panels. When these experiments were completed, the test panels were ``recovered`` with different thicknesses of insulation and the environmental conditions were reapplied to the test panels. This paper reports on the design and performance of these experiments. The data compiled during these tests supply insight into the effects of meteorological conditions, insulation R-value, insulation water vapor permeance, and roof recover on the rate that water will be removed from low-slope roofing systems.

  18. Analysis of DOE s Roof Savings Calculator with Comparison to other Simulation Engines

    SciTech Connect (OSTI)

    New, Joshua Ryan [ORNL; Huang, Yu (Joe) [White Box Technologies; Levinson, Ronnen [Lawrence Berkeley National Laboratory (LBNL); Mellot, Joe [The Garland Company; Sanyal, Jibonananda [ORNL; Childs, Kenneth W [ORNL

    2014-01-01T23:59:59.000Z

    A web-based Roof Savings Calculator (RSC) has been deployed for the Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors, contractors and researchers easily run complex roof and attic simulations. This tool employs the latest web technologies and usability design to provide an easy input interface to an annual simulation of hour-by-hour, whole-building performance using the world-class simulation tools DOE-2.1E and AtticSim. Building defaults were assigned based on national averages and can provide estimated annual energy and cost savings after the user selects nothing more than building location. In addition to cool reflective roofs, the RSC tool can simulate multiple roof and attic configurations including different roof slopes, above sheathing ventilation, radiant barriers, low-emittance surfaces, HVAC duct location, duct leakage rates, multiple layers of building materials, ceiling and deck insulation levels, and other parameters. A base case and energy-efficient alternative can be compared side-by-side to generate an energy/cost savings estimate between two buildings. The RSC tool was benchmarked against field data for demonstration homes in Ft. Irwin, CA. However, RSC gives different energy savings estimates than previous cool roof simulation tools so more thorough software and empirical validation proved necessary. This report consolidates much of the preliminary analysis for comparison of RSC s projected energy savings to that from other simulation engines.

  19. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 5, 0.05 Roofing

    SciTech Connect (OSTI)

    Not Available

    1993-05-01T23:59:59.000Z

    General information is presented for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; and system work breakdown structure. Deficiency standards and inspection methods are presented for built-up membrane; single- ply membrane; metal roofing systems; coated foam membrane; shingles; tiles; parapets; roof drainage system; roof specialties; and skylights.

  20. Global Cooling: Policies to Cool the World and Offset Global Warming from CO2 Using Reflective Roofs and Pavements

    E-Print Network [OSTI]

    Akbari, Hashem

    2010-01-01T23:59:59.000Z

    widely used building energy-efficiency standards, includingaddress cool roofs in building energy-efficiency standardsworldwide. Building energy-efficiency standards typically

  1. Building America Webinar: High-Performance Enclosure Strategies, Part I: Unvented Roof Systems and Innovative Advanced Framing Strategies

    Broader source: Energy.gov [DOE]

    This webinar, held on February 12, 2015, focused on methods to design and build roof and wall systems for high performance homes that optimize energy and moisture performance.

  2. Building America Webinar: High-Performance Enclosure Strategies, Part I: Unvented Roof Systems and Innovative Advanced Framing Strategies

    Broader source: Energy.gov [DOE]

    This presentation was delivered at the February 12, 2015, Building America webinar, High-Performance Enclosure Strategies, Part I: Unvented Roof Systems and Innovative Advanced Framing Strategies.

  3. Soiling of building envelope surfaces and its effect on solar reflectance Part I: Analysis of roofing product databases

    E-Print Network [OSTI]

    Sleiman, Mohamad

    2013-01-01T23:59:59.000Z

    coating on clay roofing tiles. Philosophical Magazine. 90:metal and glazes applied to tiles. Metal. Can be shaped tomaterial. Shingle, slate, or tile. Pieces that fit together

  4. Building American Webinar: High-Performance Enclosure Strategies, Part I: Unvented Roof Systems and Innovative Advanced Framing Strategies

    Broader source: Energy.gov [DOE]

    This webinar, held on February 12, 2015, focused on methods to design and build roof and wall systems for high performance homes that optimize energy and moisture performance.

  5. Application of Spray Foam Insulation Under Plywood and OSB Roof Sheathing (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2013-11-01T23:59:59.000Z

    Spray polyurethane foams (SPFs) have advantages over alternative insulation methods because they provide air sealing in complex assemblies, particularly roofs. Spray foam can provide the thermal, air, and vapor control layers in both new and retrofit construction. Unvented roof strategies with open cell and closed cell SPF insulation sprayed to the underside of roof sheathing have been used since the mid-1990s to provide durable and efficient building enclosures. However, there have been isolated incidents of failures (either sheathing rot or SPF delamination) that raise some general concerns about the hygrothermal performance and durability of these systems. The primary risks for roof systems are rainwater leaks, condensation from diffusion and air leakage, and built-in construction moisture. This project directly investigated rain and indirectly investigated built-in construction moisture and vapor drives. Research involved both hygrothermal modeling of a range of rain water leakage scenarios and field evaluations of in-service residential roofs. Other variables considered were climate zone, orientation, interior relative humidity, and the vapor permeance of the coating applied to the interior face of open cell SPF.

  6. Theoretical solution for light transmission of a bended hollow light guide

    SciTech Connect (OSTI)

    Kocifaj, Miroslav; Darula, Stanislav; Kittler, Richard [ICA, Slovak Academy of Sciences, 9, Dubravska Road, 845 03 Bratislava (Slovakia); Kundracik, Frantisek [Department of Experimental Physics, FMPI, Comenius University, Mlynska dolina, 842 48 Bratislava (Slovakia)

    2010-08-15T23:59:59.000Z

    Hollow light guides with very high reflective inner surfaces are novel daylight systems that collect sunlight and skylight available on the roof of buildings transporting it into deep or windowless interiors in building cores. Thus the better utilization of daylight can result in energy savings and wellbeing in these enclosed indoor spaces. An analytical complex solution of a straight tube system was solved in the HOLIGILM method with a user-friendly tool available on the http://www.holigilm.info. An even more difficult light flow transport is to be determined in bended tubes usually placed on sloped roofs where a bend is necessary to adjust the vertical pass through the ceilings. This paper presents the theoretical derivation of the model with its graphical representation and coordinate system respecting backward ray-tracing bend distortions. To imagine the resulting illuminance on the horizontal plane element in the interior, the virtual ray (i.e. luminance in an elementary solid angle) has to pass the ceiling diffuser interface, the inner mirror like tube with a bend, through a roof cupola attachment to the element of the sky and sun light source. Due to this complexity and the lengthy derivation and explanations more practical applications will be published later in a separate contribution. (author)

  7. A Prototype Roof Deck Designed to Self-Regulate Deck Temperature and Reduce Heat Transfer

    SciTech Connect (OSTI)

    Miller, William A [ORNL] [ORNL

    2011-01-01T23:59:59.000Z

    A prototype roof and attic assembly exploits the use of radiation, convection and insulation controls to reduce its peak day heat transfer by almost 85 percent of the heat transfer crossing a conventional roof and attic assembly. The assembly exhibits attic air temperatures that do not exceed the maximum daily outdoor ambient temperature. The design includes a passive ventilation scheme that pulls air from the soffit and attic into an inclined air space above the roof deck. The design complies with fire protection codes because the air intake is internal and closed to the elements. Field data were benchmarked against an attic computer tool and simulations made for new and retrofit constructions in hot, moderate and cold climates to gauge the cost of energy savings and potential payback.

  8. A Prototype Roof Deck Designed to Self-Regulate Deck Temperature and Reduce Heat Transfer

    SciTech Connect (OSTI)

    Miller, William A [ORNL] [ORNL

    2011-01-01T23:59:59.000Z

    A prototype roof and attic assembly exploits the use of radiation, convection and insulation controls to reduce the heat transfer penetrating its roof deck by almost 85% of the heat transfer crossing a conventional roof and attic assembly. The assembly exhibited attic air temperatures that did not exceed the peak day outdoor ambient temperature. The design includes a passive ventilation scheme that pulls air from the soffit and attic into an inclined air space above the deck. The design complies with fire protection codes because the air intake is internal and closed to the elements. Field data were benchmarked against an attic computer tool and simulations made for new and retrofit home constructions in hot, moderate and cold climates to access economics for the assembly.

  9. Convex Hulls of Varieties and Entanglement Measures Based on the Roof Construction

    E-Print Network [OSTI]

    Tobias J. Osborne

    2004-03-12T23:59:59.000Z

    In this paper we study the problem of calculating the convex hull of certain affine algebraic varieties. As we explain, the motivation for considering this problem is that certain pure-state measures of quantum entanglement, which we call polynomial entanglement measures, can be represented as affine algebraic varieties. We consider the evaluation of certain mixed-state extensions of these polynomial entanglement measures, namely convex and concave roofs. We show that the evaluation of a roof-based mixed-state extension is equivalent to calculating a hyperplane which is multiply tangent to the variety in a number of places equal to the number of terms in an optimal decomposition for the measure. In this way we provide an implicit representation of optimal decompositions for mixed-state entanglement measures based on the roof construction.

  10. Using Cool Roofs to Reduce Energy Use, Greenhouse Gas Emissions, and Urban Heat-island Effects: Findings from an India Experiment

    E-Print Network [OSTI]

    Akbari, Hashem

    2011-01-01T23:59:59.000Z

    like Brazil, has strong programs on energy efficiency, andenergy savings due to cool roofs for the median climate in Brazil,energy savings due to cool roofs for the median climate in Brazil,

  11. Library of Science & Medicine Roof Replacement and Related Work December 11, 2000 DSR # 0059-00 BSH

    E-Print Network [OSTI]

    Library of Science & Medicine Roof Replacement and Related Work December 11, 2000 DSR # 0059-00 BSH in sufficient de- tail to facilitate continued evaluation of Applications for Payment and progress reports of Science & Medicine Roof Replacement and Related Work December 11, 2000 DSR # 0059-00 BSH b. Submittals. c

  12. Instability leading to coal bumps and nonlinear evolutionary mechanisms for a coal-pillar-and-roof system

    E-Print Network [OSTI]

    Jiao, Jiu Jimmy

    Instability leading to coal bumps and nonlinear evolutionary mechanisms for a coal mechanisms of the mechanical system that is composed of the stiff hosts (roof and floor) and the coal pillar using catastrophe theory. It is assumed that the roof is an elastic beam and the coal pillar is a strain

  13. INSTANTANEOUS FREQUENCY VERSUS TIME FOR 7 BUILDINGS B.0466 Los Angeles, 15250 Ventura Blvd., Roof (13th floor) (pp. 7)

    E-Print Network [OSTI]

    Southern California, University of

    APPENDIX B INSTANTANEOUS FREQUENCY VERSUS TIME FOR 7 BUILDINGS B.0466 Los Angeles, 15250 Ventura.5455 Los Angeles, 16000 Ventura Blvd., Roof (13th floor) (pp. 11) B.5457 Los Angeles, 8436 West 3rd ST., Roof (10th floor) (pp. 16) #12;#12;B.0466­1 Appendix B.0466 LOS ANGELES, 15250 VENTURA BLVD. Table B

  14. Scaling of economic benefits from Green Roof implementation in Washington, DC.

    SciTech Connect (OSTI)

    Niu, H.; Clark, C. E.; Zhou, J.; Adriaens, P.; Environmental Science Division; Dalian Univ. of Technology; Univ. of Michigan

    2010-06-01T23:59:59.000Z

    Green roof technology is recognized for mitigating stormwater runoff and energy consumption. Methods to overcome the cost gap between green roofs and conventional roofs were recently quantified by incorporating air quality benefits. This study investigates the impact of scaling on these benefits at the city-wide scale using Washington, DC as a test bed because of the proposed targets in the 20-20-20 vision (20 million ft{sup 2} by 2020) articulated by Casey Trees, a nonprofit organization. Building-specific stormwater benefits were analyzed assuming two proposed policy scenarios for stormwater fees ranging from 35 to 50% reduction for green roof implementation. Heat flux calculations were used to estimate building-specific energy savings for commercial buildings. To assess benefits at the city scale, stormwater infrastructure savings were based on operational savings and size reduction due to reduced stormwater volume generation. Scaled energy infrastructure benefits were calculated using two size reductions methods for air conditioners. Avoided carbon dioxide, nitrogen oxide (NOx), and sulfur dioxide emissions were based on reductions in electricity and natural gas consumption. Lastly, experimental and fugacity-based estimates were used to quantify the NOx uptake by green roofs, which was translated to health benefits using U.S. Environmental Protection Agency models. The results of the net present value (NPV) analysis showed that stormwater infrastructure benefits totaled $1.04 million (M), while fee-based stormwater benefits were $0.22-0.32 M/y. Energy savings were $0.87 M/y, while air conditioner resizing benefits were estimated at $0.02 to $0.04 M/y and avoided emissions benefits (based on current emission trading values) were $0.09 M-0.41 M/y. Over the lifetime of the green roof (40 years), the NPV is about 30-40% less than that of conventional roofs (not including green roof maintenance costs). These considerable benefits, in concert with current and emerging policy frameworks, may facilitate future adoption of this technology.

  15. In situ thermal performance of APP modified bitumen roof membranes coated with reflective coatings

    SciTech Connect (OSTI)

    Carlson, J.D.; Smith, T.L. (National Roofing Contractors Association, Rosemont, IL (United States)); Christian, J.E. (Oak Ridge National Lab., TN (United States))

    1992-01-01T23:59:59.000Z

    A multi-faceted field research program regarding seven atactic polypropylene (APP) modified bitumen membrane roof systems and four reflective coatings began in 1991. This long-term project is evaluating the performance of various APP modified bitumen membranes (both coated and uncoated), the comparative performance of coating application soon after membrane installation versus preweathering, coating performance, and aspects of recoating. This paper is a progress report on the in situ thermal performance of the various types of coatings compared to the thermal performance of the exposed membrane. The thermal performance of an adjacent ballasted ethylene propylene diene terpolymer (EPDM) roofing system is also described.

  16. In situ thermal performance of APP modified bitumen roof membranes coated with reflective coatings

    SciTech Connect (OSTI)

    Carlson, J.D.; Smith, T.L. [National Roofing Contractors Association, Rosemont, IL (United States); Christian, J.E. [Oak Ridge National Lab., TN (United States)

    1992-10-01T23:59:59.000Z

    A multi-faceted field research program regarding seven atactic polypropylene (APP) modified bitumen membrane roof systems and four reflective coatings began in 1991. This long-term project is evaluating the performance of various APP modified bitumen membranes (both coated and uncoated), the comparative performance of coating application soon after membrane installation versus preweathering, coating performance, and aspects of recoating. This paper is a progress report on the in situ thermal performance of the various types of coatings compared to the thermal performance of the exposed membrane. The thermal performance of an adjacent ballasted ethylene propylene diene terpolymer (EPDM) roofing system is also described.

  17. TARSHA-KURDI, F., LANDES, T., GRUSSENMEYER, P., (2008). Extended RANSAC algorithm for automatic detection of building roof planes from Lidar data.

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    2008-01-01T23:59:59.000Z

    detection of building roof planes from Lidar data. The Photogrammetric Journal of Finland. Vol. 21, n°1, 2008, pp.97-109. EXTENDED RANSAC ALGORITHM FOR AUTOMATIC DETECTION OF BUILDING ROOF PLANES FROM LIDAR the detection of 3D building roof planes are of crucial importance. For this purpose, this paper studies

  18. Variable area light reflecting assembly

    DOE Patents [OSTI]

    Howard, T.C.

    1986-12-23T23:59:59.000Z

    Device is described for tracking daylight and projecting it into a building. The device tracks the sun and automatically adjusts both the orientation and area of the reflecting surface. The device may be mounted in either a wall or roof of a building. Additionally, multiple devices may be employed in a light shaft in a building, providing daylight to several different floors. The preferred embodiment employs a thin reflective film as the reflecting device. One edge of the reflective film is fixed, and the opposite end is attached to a spring-loaded take-up roller. As the sun moves across the sky, the take-up roller automatically adjusts the angle and surface area of the film. Additionally, louvers may be mounted at the light entrance to the device to reflect incoming daylight in an angle perpendicular to the device to provide maximum reflective capability when daylight enters the device at non-perpendicular angles. 9 figs.

  19. Variable area light reflecting assembly

    DOE Patents [OSTI]

    Howard, Thomas C. (Raleigh, NC)

    1986-01-01T23:59:59.000Z

    Device for tracking daylight and projecting it into a building. The device tracks the sun and automatically adjusts both the orientation and area of the reflecting surface. The device may be mounted in either a wall or roof of a building. Additionally, multiple devices may be employed in a light shaft in a building, providing daylight to several different floors. The preferred embodiment employs a thin reflective film as the reflecting device. One edge of the reflective film is fixed, and the opposite end is attached to a spring-loaded take-up roller. As the sun moves across the sky, the take-up roller automatically adjusts the angle and surface area of the film. Additionally, louvers may be mounted at the light entrance to the device to reflect incoming daylight in an angle perpendicular to the device to provide maximum reflective capability when daylight enters the device at non-perpendicular angles.

  20. Effect of roof slope and thickness on the performance of a saltstone vault

    SciTech Connect (OSTI)

    Yu, A.D.; Lam, Poh-Sang; Hsu, R.H.

    1995-09-01T23:59:59.000Z

    At the Savannah River Site, low-level radioactive decontaminated salt solution is mixed with slag, flyash, and cement to form a grout-like material called ``Saltstone.`` The Saltstone is poured into concrete vaults constructed at the Saltstone Disposal Facility (SDF). The SDF is designed for the release of contaminants in a slow, controlled manner over thousands of years. The impact of SDF on groundwater has been studied in a radiological performance assessment (PA). Groundwater models were used to predict the fluid flow and contaminant transport at SDF. The models predicted a spatial contaminant concentration distribution in groundwater as a function of time. This study focuses on the roof configuration of Saltstone vault, with special interests in cost-effectiveness. We conducted a study to evaluate the effect of roof slope and thickness on the performance of a Saltstone vault. Four roof configurations were simulated. The tool used for the simulation was ECLIPSE, a finite-difference petroleum reservoir engineering code with an environmental tracer option. Nitrate was used as the ``tracer`` contaminant. In this study, ECLIPSE solves the two-phase two-dimensional flow and transport problem up to 10,000 years. This paper describes a modeling study used to evaluate roof design options for the Saltstone vault.

  1. Laying the Foundation for a Solar America: The Million Solar Roofs Initiative

    SciTech Connect (OSTI)

    Strahs, G.; Tombari, C.

    2006-10-01T23:59:59.000Z

    As the U.S. Department of Energy's Solar Energy Technology Program embarks on the next phase of its technology acceptance efforts under the Solar America Initiative, there is merit to examining the program's previous market transformation effort, the Million Solar Roofs Initiative. Its goal was to transform markets for distributed solar technologies by facilitating the installation of solar systems.

  2. Ten Years at the Calif. Energy Commission White Roofs to Cool your Building, your City and

    E-Print Network [OSTI]

    Kammen, Daniel M.

    Ten Years at the Calif. Energy Commission & White Roofs to Cool your Building, your City and (this" 32" 37" 42" 50" CEC Max Screen Area (1400 in2 or ~57.4 diagonal inches) Energy Star 3.0 TVs (10 is new !) Cool the World Arthur H. Rosenfeld, Former Commissioner California Energy Commission

  3. EPIC-RoofNet: An Experimental Testbed for Solar-powered Wireless Sensor Networks

    E-Print Network [OSTI]

    Nasipuri, Asis

    EPIC-RoofNet: An Experimental Testbed for Solar-powered Wireless Sensor Networks Amitangshu Pal experiments on solar-powered sensor nodes. Due to constraints in cost and size, the solar panels of solar energy available at such solar-powered sensor nodes can be highly unpredictable and at times

  4. The case for cool roofs Ronnen Levinson, Lawrence Berkeley National Laboratory, RMLevinson@LBL.gov

    E-Print Network [OSTI]

    on the electrical grid by reducing late-afternoon peak power demand. Widespread use of cool roofs can lower outdoor (e.g., better retention of plasticizers and incorporation of biocides) and, therefore, are expected, because the pigments are responsible for only a small fraction of the product cost. Only for high

  5. Countries Commit to White Roofs, Potentially Offsetting the Emissions of Over 300 Power Plants

    Broader source: Energy.gov [DOE]

    India, Mexico, and the United States have signed up to join the Cool Roofs Working Group, which was announced yesterday in Abu Dhabi at the second Clean Energy Ministerial -- a high-level global forum to promote policies and programs that advance clean energy technology, to share lessons learned and best practices and to encourage the transition to a global clean energy economy.

  6. HEAT TRANSFERS IN A DOUBLE SKIN ROOF VENTILATED BY NATURAL CONVECTION IN SUMMER TIME

    E-Print Network [OSTI]

    Boyer, Edmond

    1 HEAT TRANSFERS IN A DOUBLE SKIN ROOF VENTILATED BY NATURAL CONVECTION IN SUMMER TIME P. H and the sheet metal: This is ventilation by natural convection. The remaining conductive heat from the sheet or in tropical and arid countries. In this work, radiation, convection and conduction heat transfers

  7. 32 IAEI NEWS March.April 2009 www.iaei.org still on the roof

    E-Print Network [OSTI]

    Johnson, Eric E.

    of a PV system, we need to look at one more component usually located on the roof. This is the PV source source-circuit combiner is found on larger residen- tial systems and on most large commercial systems. PV Need Combiner The rated output voltage of the PV modules and the inverter dc input characteristics

  8. Development of a new roof bolt technology to improve gate-road performance

    SciTech Connect (OSTI)

    Caggiano, V.; Rauch, G.; Beck, K.-D.; Chen, J. [Hilti, Inc. (United States)

    2005-10-01T23:59:59.000Z

    Hilti has developed, in conjunction with Foundation Coal, a self-drilling bolt that cuts roof bolting times. The system uses a wet, self-drilling, hollow bolt technology with a self-contained resin cartridge. The resin is dispensed using an injection adapter that provides the high pressure water needed to dispense the resin. The OneStep roof bolt contains an axially shifting mixer that ensures the resin is properly mixed as it exits the water ports near the end of the bolt near the drill head. This eliminates the opportunity for plastic materials to interface between the strata and the bolt. In 2004 the OneStep Bolt was successfully installed in DSK's Prosper Haniel Colliery in Germany, achieving a 42% reduction in single-boom roof bolt cycle time and a 36% reduction in twin-boom roof bolt cycle time. Foundation Coal will be installing 2000 6 ft active bolts in one of the North Appalachian longwall locations. 1 fig.

  9. Studies of Photovoltaic Roofing Systems at Wind Engineering and Fluids Laboratory at Colorado State University

    E-Print Network [OSTI]

    of the solar power market. As a result of our technology lead, SunPower is today a global leader in the market for solar power." In addition to SunPower Systems, over the years, Dr. Bienkiewicz and his team at WEFL have assisted other companies and inventors in development of various loose-laid and attached roofing systems

  10. TASK 2.5.7 FIELD EXPERIMENTS TO EVALUATE COOL-COLORED ROOFING

    SciTech Connect (OSTI)

    Miller, William A [ORNL; Cherry, Nigel J [ORNL; Allen, Richard Lowell [ORNL; Childs, Phillip W [ORNL; Atchley, Jerald Allen [ORNL; Ronnen, Levinson [Lawrence Berkeley National Laboratory (LBNL); Akbari, Hashem [Lawrence Berkeley National Laboratory (LBNL); Berhahl, Paul [Lawrence Berkeley National Laboratory (LBNL)

    2010-03-01T23:59:59.000Z

    Aesthetically pleasing dark roofs can be formulated to reflect like a highly reflective white roof in the near infrared portion of the solar spectrum. New paint pigments increase the near infrared reflectance of exterior finishes by minimizing the absorption of near-infrared radiation (NIR). The boost in the NIR reflectance drops the surface temperatures of roofs and walls, which in turn reduces cooling-energy use and provides savings for the homeowner and relief for the utilities. In moderate and hot climates, a roof surface with high solar reflectance and high thermal emittance was shown by Akbari et al. (2004) and by Parker and Sherwin (1998) to reduce the exterior temperature and produce savings in comfort cooling. The new cool color pigments can potentially reduce emissions of carbon dioxide, which in turn reduces metropolitan heat buildup and urban smog. The pigments can also help conserve water resources otherwise used to clean and process fuel consumed by fossil-fuel driven power plants. Cool roofs also result in a lower ambient temperature that further decreases the need for air conditioning, retards smog formation, and improves thermal comfort. Parker, Sonne and Sherwin (2002) demonstrated that white barrel and white flat tiles reduced cooling energy consumption by 22% of the base load used by an adjacent and identical home having direct nailed dark shingles. Part of the savings was due to the reflectance of the white tiles; however, another part was due to the mass of the tile and to the venting occurring within the double batten installation. With, Cherry and Haig (2009) have studied the influence of the thermal mass and batten space ventilation and have found that, referenced to an asphalt shingle system, it can be equivalent to an additional 28 points of solar reflectivity. The double batten arrangement has wooden counter battens laid vertically (soffit-to-ridge) against the roof deck, and then the conventional battens are laid horizontally across the counter battens, providing a nailing surface for the concrete tile. This double batten construction forms an inclined air channel running from the soffit to the ridge. The bottom surface of the channel is formed by the roof decking and is relatively flat and smooth. The top surface is created by the underside of the roofing tiles, and is designed to be an air permeable covering to alleviate the underside air pressure and minimize wind uplift on the tiles. The resulting air flows also have a cooling influence which further complicates prediction of the heat penetrating through the deck because an accurate measure of the airflow is required to predict the heat transfer. Measured temperatures and heat flows at the roof surface, within the attic and at the ceiling of the houses are discussed as well as the power usage to help gauge the benefit of cool-pigmented reflective roof products fitted with and without ventilation above the roof deck. Ventilation occurring above the deck is an inherent feature for tile roof assemblies, and is formed by an air space between the exterior face of the roof sheathing and the underside of the tile. The greater the tile s profile the greater is the effect of the ventilation which herein is termed above-sheathing ventilation (ASV). However, because of the complexity of the thermally induced flow, little credit is allowed by state and federal building codes. ASHRAE (2005) provides empirical data for the effective thermal resistance of plane air spaces. A -in. (0.0191-m) plane air space inclined at 45 with the horizontal has an RUS-0.85 (RSI-0.15) . Our intent is to help further deploy cool color pigments in roofs by conducting field experiments to evaluate the new cool-colored roofing materials in the hot climate of Southern California. The collected data will be used to showcase and market the performance of new cool-roof products and also to help formulate and validate computer codes capable of calculating the heat transfer occurring within the attic and the whole building. Field measures and computer predictions showed that the d

  11. Sustainable design for a subtropical green roof with local, recyclable substrates and native plant species 

    E-Print Network [OSTI]

    Huerta, Angelica

    2011-01-11T23:59:59.000Z

    and recycled materials needs to be included as a means of minimizing environmental impacts and improving local economies. The goal of this research was to test for vegetation and substrate suitability for a subtropical climate green roof found in East Texas...

  12. Rainwater harvesting system with roof catchment, gutter, downspout, storage and drip irrigation system.

    E-Print Network [OSTI]

    Stephens, Graeme L.

    Rainwater harvesting system with roof catchment, gutter, downspout, storage and drip irrigation:30 am systems: rain barrel, drip irrigation, stock watering Program: 8:30 am ­ 4:00 pm indoor usage system. Douglas County Conservation District and the Rural Water Authority of Douglas County Present: Who

  13. Thermal Performance of Exposed Composed Roofs in Very Hot Dry Desert Region in Egypt (Toshky)

    E-Print Network [OSTI]

    Khalil, M. H.; Sheble, S.; Morsey, M. S.; Fakhry, S.

    2010-01-01T23:59:59.000Z

    is considered the major part of the building envelop which exposed to high thermal load due to the high solar intensity and high outdoor air temperature through summer season which reach to 6 months. In Egypt the thermal effect of roof is increased as one go...

  14. In-Depth Analysis of Simulation Engine Codes for Comparison with DOE s Roof Savings Calculator and Measured Data

    SciTech Connect (OSTI)

    New, Joshua Ryan [ORNL; Levinson, Ronnen [Lawrence Berkeley National Laboratory (LBNL); Huang, Yu (Joe) [White Box Technologies; Sanyal, Jibonananda [ORNL; Miller, William A [ORNL; Mellot, Joe [The Garland Company; Childs, Kenneth W [ORNL; Kriner, Scott [Green Metal Consulting, Inc.

    2014-06-01T23:59:59.000Z

    The Roof Savings Calculator (RSC) was developed through collaborations among Oak Ridge National Laboratory (ORNL), White Box Technologies, Lawrence Berkeley National Laboratory (LBNL), and the Environmental Protection Agency in the context of a California Energy Commission Public Interest Energy Research project to make cool-color roofing materials a market reality. The RSC website and a simulation engine validated against demonstration homes were developed to replace the liberal DOE Cool Roof Calculator and the conservative EPA Energy Star Roofing Calculator, which reported different roof savings estimates. A preliminary analysis arrived at a tentative explanation for why RSC results differed from previous LBNL studies and provided guidance for future analysis in the comparison of four simulation programs (doe2attic, DOE-2.1E, EnergyPlus, and MicroPas), including heat exchange between the attic surfaces (principally the roof and ceiling) and the resulting heat flows through the ceiling to the building below. The results were consolidated in an ORNL technical report, ORNL/TM-2013/501. This report is an in-depth inter-comparison of four programs with detailed measured data from an experimental facility operated by ORNL in South Carolina in which different segments of the attic had different roof and attic systems.

  15. Global Cooling: Policies to Cool the World and Offset Global Warming from CO2 Using Reflective Roofs and Pavements

    SciTech Connect (OSTI)

    Akbari, Hashem; Levinson, Ronnen; Rosenfeld, Arthur; Elliot, Matthew

    2009-08-28T23:59:59.000Z

    Increasing the solar reflectance of the urban surface reduce its solar heat gain, lowers its temperatures, and decreases its outflow of thermal infrared radiation into the atmosphere. This process of 'negative radiative forcing' can help counter the effects of global warming. In addition, cool roofs reduce cooling-energy use in air conditioned buildings and increase comfort in unconditioned buildings; and cool roofs and cool pavements mitigate summer urban heat islands, improving outdoor air quality and comfort. Installing cool roofs and cool pavements in cities worldwide is a compelling win-win-win activity that can be undertaken immediately, outside of international negotiations to cap CO{sub 2} emissions. We propose an international campaign to use solar reflective materials when roofs and pavements are built or resurfaced in temperate and tropical regions.

  16. Heat transfers in a double-skin roof ventilated by natural convection in summer time

    E-Print Network [OSTI]

    Biwole, Pascal; Pompeo, C

    2013-01-01T23:59:59.000Z

    The double-skin roofs investigated in this paper are formed by adding a metallic screen on an existing sheet metal roof. The system enhances passive cooling of dwellings and can help diminishing power costs for air conditioning in summer or in tropical and arid countries. In this work, radiation, convection and conduction heat transfers are investigated. Depending on its surface properties, the screen reflects a large amount of oncoming solar radiation. Natural convection in the channel underneath drives off the residual heat. The bi-dimensional numerical simulation of the heat transfers through the double skin reveals the most important parameters for the system's efficiency. They are, by order of importance, the sheet metal surface emissivity, the screen internal and external surface emissivity, the insulation thickness and the inclination angle for a channel width over 6 cm. The influence of those parameters on Rayleigh and Nusselt numbers is also investigated. Temperature and air velocity profiles on seve...

  17. Performance of 3-Sun Mirror Modules on Sun Tracking Carousels on Flat Roof Buildings

    SciTech Connect (OSTI)

    Fraas, Dr. Lewis [JX Crystals, Inc.; Avery, James E. [JX Crystals, Inc.; Minkin, Leonid M [ORNL; Maxey, L Curt [ORNL; Gehl, Anthony C [ORNL; Hurt, Rick A [ORNL; Boehm, Robert F [ORNL

    2008-01-01T23:59:59.000Z

    Commercial buildings represent a near term market for cost competitive solar electric power provided installation costs and solar photovoltaic module costs can be reduced. JX Crystals has developed a carousel sun tracker that is prefabricated and can easily be deployed on building flat roof tops without roof penetration. JX Crystals is also developing 3-sun PV mirror modules where less expensive mirrors are substituted for two-thirds of the expensive single crystal silicon solar cell surface area. Carousels each with four 3-sun modules have been set up at two sites, specifically at Oak Ridge National Lab and at the University of Nevada in Las Vegas. The test results for these systems are presented.

  18. Roof and Attic Design Guidelines for new and retrofit Construction of Homes in Hot and Coild Climates

    SciTech Connect (OSTI)

    Desjarlais, Andre Omer [ORNL] [ORNL; LaFrance, Marc [International Energy Agency] [International Energy Agency

    2013-01-01T23:59:59.000Z

    Some guidelines for improving the energy efficiency of roofs and attics are presented and are based on the research of the DOE Building Technology. The results of combined analytical and experimental studies were used to benchmark computer tools, which in turn, were used to simulate homes in hot and cold climates. Adding floor and roof insulation, above deck ventilation, radiant barriers, cool color shingle, metal or tile roofs, sealing the attic floor, sealing the duct system and sealing the attic were simulated to compute the cost of energy savings. Results are prioritized to help building owners make an informed economic decision when contemplating roof and attic retrofits. Sealing the attic floor is a top retrofit option. The sealed attic approach and a new prototype roof assembly an insulated and ventilated roof are good options for retrofit work but have paybacks ranging from 15 to 25 years. A new sealed attic concept was simulated and computations show its simple payback is about 10 to 12 years in hot and cold climates; its first cost is significantly reduced from that of a spray foam approach. For new construction the best option is to keep the ducts out of the attic, make sure the attic floor is sealed and add at least code level of insulation to the ceiling.

  19. Calculation of the convex roof for an open entangled harmonic oscillator system

    SciTech Connect (OSTI)

    Landau, Mayer A.; Stroud, C. R. Jr. [Institute of Optics, University of Rochester, Rochester, New York 14627 (United States)

    2010-05-15T23:59:59.000Z

    We explicitly calculate the time dependence of entanglement via the convex roof extension for a system of noninteracting harmonic oscillators. These oscillators interact only indirectly with each other by way of a zero-temperature bath. The initial state of the oscillators is taken to be that of an entangled Schroedinger-cat state. This type of initial condition leads to superexponential decay of the entanglement when the initial state has the same symmetry as the interaction Hamiltonian.

  20. Entanglement detection and lower bound of convex-roof extension of negativity

    E-Print Network [OSTI]

    Li, Ming; Fei, Shao-Ming; 10.1088/1751-8113/45/3/035301

    2012-01-01T23:59:59.000Z

    We present a set of inequalities based on mean values of quantum mechanical observables nonlinear entanglement witnesses for bipartite quantum systems. These inequalities give rise to sufficient and necessary conditions for separability of all bipartite pure states and even some mixed states. In terms of these mean values of quantum mechanical observables a measurable lower bound of the convex-roof extension of the negativity is derived.

  1. Convex-roof extended negativity as an entanglement measure for bipartite quantum systems

    E-Print Network [OSTI]

    Soojoon Lee; Dong Pyo Chi; Sung Dahm Oh; Jaewan Kim

    2003-10-04T23:59:59.000Z

    We extend the concept of the negativity, a good measure of entanglement for bipartite pure states, to mixed states by means of the convex-roof extension. We show that the measure does not increase under local quantum operations and classical communication, and derive explicit formulae for the entanglement measure of isotropic states and Werner states, applying the formalism presented by Vollbrecht and Werner [Phys. Rev. A {\\bf 64}, 062307 (2001)].

  2. Entanglement detection and lower bound of convex-roof extension of negativity

    E-Print Network [OSTI]

    Ming Li; Tong-Jiang Yan; Shao-Ming Fei

    2011-12-30T23:59:59.000Z

    We present a set of inequalities based on mean values of quantum mechanical observables nonlinear entanglement witnesses for bipartite quantum systems. These inequalities give rise to sufficient and necessary conditions for separability of all bipartite pure states and even some mixed states. In terms of these mean values of quantum mechanical observables a measurable lower bound of the convex-roof extension of the negativity is derived.

  3. Research on the Effect of a Planting Roof on the Thermal Load of a Business Building

    E-Print Network [OSTI]

    Zhang, W.; Wu, J.; Wei, Y.; Gao, X.

    2006-01-01T23:59:59.000Z

    ICEBO2006, Shenzhen, China Enve lope Technologies for Building Energy Efficiency Vol.II-4-2 Research on the Effect of a Planting Roof on the Thermal Load of a Business Building Weijie Zhang Jinshun Wu Yiran Wei Xudong Gao... ICEBO2006, Shenzhen, China Enve lope Technologies for Building Energy Efficiency Vol.II-4-2 room has been made and some theoretical relations between outdoor air temperature and indoor thermal load within certain region have been...

  4. Roof system effects on in-situ thermal performance of HCFC polyisocyanurate insulation. [Hydrochlorofluorocarbon (HCFC)

    SciTech Connect (OSTI)

    Christian, J.E.; Desjarlais, A.O.; Courville, G.; Graves, R.

    1992-01-01T23:59:59.000Z

    Industry-produced, permeably-faced, experimental polyisocyanurate (PIR) laminated boardstock foamed with several different hydrochlorofluorcarbons (HCFCS) is undergoing in-situ testing at the Building Envelopes Research User Center at Oak Ridge National Laboratory (ORNL). The overall objective of this research is to determine the long term thermal performance differences between PIR foamed with CFC-11 and PIR foamed with HCFC-123, HCFC-14lb and blends of HCFCs. Boards from the same batch were installed in outdoor test facilities and instrumented in part to determine if the insulation thermal performance aging characteristics are dependent on how they are handled and installed in the field. One of the major contributions of this research is the field validation of an accelerated thermal aging procedure. The laboratory measurements of the apparent thermal conductivity (k) of 10-mm-thick slices conducted over a period of less than a year are used to predict the k of 38-50-mm-thick PIR laminated board stock for 12--20 years after production. In situ thermal performance measurements of these well characterized three-year-old boards under white and under black ethylene propylene diene monomer (EPDM) membranes are compared with the accelerated aging procedure and with boards from the same batch in different roofing systems: mechanically attached EPDM, fully adhered EPDM, and built-up roof (BUR). The comparison indicates that this accelerated aging procedure should be seriously considered for providing in-service thermal performance information to building owners and roofing contractors.

  5. Roof system effects on in-situ thermal performance of HCFC polyisocyanurate insulation

    SciTech Connect (OSTI)

    Christian, J.E.; Desjarlais, A.O.; Courville, G.; Graves, R.

    1992-10-01T23:59:59.000Z

    Industry-produced, permeably-faced, experimental polyisocyanurate (PIR) laminated boardstock foamed with several different hydrochlorofluorcarbons (HCFCS) is undergoing in-situ testing at the Building Envelopes Research User Center at Oak Ridge National Laboratory (ORNL). The overall objective of this research is to determine the long term thermal performance differences between PIR foamed with CFC-11 and PIR foamed with HCFC-123, HCFC-14lb and blends of HCFCs. Boards from the same batch were installed in outdoor test facilities and instrumented in part to determine if the insulation thermal performance aging characteristics are dependent on how they are handled and installed in the field. One of the major contributions of this research is the field validation of an accelerated thermal aging procedure. The laboratory measurements of the apparent thermal conductivity (k) of 10-mm-thick slices conducted over a period of less than a year are used to predict the k of 38-50-mm-thick PIR laminated board stock for 12--20 years after production. In situ thermal performance measurements of these well characterized three-year-old boards under white and under black ethylene propylene diene monomer (EPDM) membranes are compared with the accelerated aging procedure and with boards from the same batch in different roofing systems: mechanically attached EPDM, fully adhered EPDM, and built-up roof (BUR). The comparison indicates that this accelerated aging procedure should be seriously considered for providing in-service thermal performance information to building owners and roofing contractors.

  6. Effect of the open roof on low frequency acoustic propagation in street canyons

    E-Print Network [OSTI]

    Richoux, Olivier; Pelat, Adrien; Félix, Simon; Lihoreau, Bertrand

    2009-01-01T23:59:59.000Z

    This paper presents an experimental, numerical and analytical study of the effect of open roof on acoustic propagation along a 3D urban canyon. The experimental study is led by means of a street scale model. The numerical results are performed with a 2D Finite Difference in Time Domain approach adapted to take into account the acoustic radiation losses due to the street open roof. An analytical model, based on the modal decomposition of the pressure field in a horizontal plane mixed with a 2D image sources model to describe the attenuation along the street, is also proposed. Results are given for several frequencies in the low frequency domain (1000-2500 Hz). The comparison of the three approaches shows a good agreement until f=100 Hz at full scale, the analytical model and the 2D numerical simulation adapted to 3D permit to modelize the acoustic propagation along a street. For higher frequency, experimental results show that the leakeage, due to the street open roof, is not anymore uniformly distributed on a...

  7. The Impact of Above-Sheathing Ventilation on the Thermal and Moisture Performance of Steep-Slope Residential Roofs and Attics 

    E-Print Network [OSTI]

    Miller, W.; Karagiozis, A.; Wilson, J.

    2006-01-01T23:59:59.000Z

    THE IMPACT OF ABOVE-SHEATHING VENTILATION ON THE THERMAL AND MOISTURE PERFORMANCE OF STEEP-SLOPE RESIDENTIAL ROOFS AND ATTICS William (Bill) Miller Research Scientist Oak Ridge National Laboratory Oak Ridge, Tennessee Joe Wilson Product... Manager Metro Roof Products Oceanside, California Achilles Karagiozis Research Scientist Oak Ridge National Laboratory Oak Ridge, Tennessee ABSTRACT Field studies were conducted on several attic assemblies having stone-coated metal shake roofs...

  8. Text-Alternative Version of Building America Webinar: High-Performance Enclosure Strategies, Part 1: Unvented Roof Systems and Innovative Advanced Framing Strategies

    Broader source: Energy.gov [DOE]

    This webinar, held on February 12, 2015, focused on methods to design and build roof and wall systems for high performance homes that optimize energy and moisture performance.

  9. Use of the finite element method to predict roof collapse and subsidence resulting from the underground gasification of coal

    SciTech Connect (OSTI)

    Jegbefume, E.U.

    1981-01-01T23:59:59.000Z

    The plane strain two-dimensional finite element model employing the method of negative reaction loading was used to model roof collapse and subsidence that result from underground coal gasification. Subsidence results from a preliminary finite element model were compared with those from a theoretical model having identical assumptions. The finite element model was extended to include dry zones of rock around the cavity resulting from the underground gasification. The model was further extended to include thermal loading, thermal softening and roof collapse. Roof collapse initiation and growth were modelled by examining the portion of the roof immediately above the cavity. A creep program utilizing the method incremental strains was developed and run in conjunction with the Pafec 70 + program. The overburden rock was treated as a linear viscoelastic material having deformation parameters of the generalized Kelvin model. Finally, the finite element model was used to carry out a case history study of subsidence and roof collapse of an underground gasification field experiment in Wyoming.

  10. Smart lighting: New Roles for Light

    E-Print Network [OSTI]

    Salama, Khaled

    Smart lighting: New Roles for Light in the Solid State Lighting World Robert F. Karlicek, Jr. Director, Smart Lighting Engineering Research Center Professor, Electrical, Systems and Computer Lighting · What is Smart Lighting · Technology Barriers to Smart Lighting · Visible Light Communications

  11. CEBAF Center Roof Work to Impact Parking Lot, Loading Dock Area | Jefferson

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office511041clothAdvanced Materials Advanced. C o w l i t z C o . C l a r k C o'IUHopper c omputeLab Roof

  12. Commercial Lighting

    Broader source: Energy.gov [DOE]

    Commercial lighting accounts for more than 20 percent of total commercial building energy use. The Energy Department works to reduce lighting energy use through research and deployment.

  13. Proposal for the award of an industrial support contract for minor metalwork, metal fittings, cladding and roofing at CERN

    E-Print Network [OSTI]

    2006-01-01T23:59:59.000Z

    This document concerns the award of a contract for minor metalwork, metal fittings, cladding and roofing at CERN. The Finance Committee is invited to agree to the negotiation of a contract with the firm INIZIATIVE INDUSTRIALI SRL (IT), the lowest bidder, for the provision of minor metalwork, metal fittings, cladding and roofing at CERN for three years for a total amount not exceeding 1 467 895 euros (2 258 301 Swiss francs), not subject to revision for two years. The contract will include options for two one-year extensions beyond the initial three-year period.

  14. Squashed entanglement for multipartite states and entanglement measures based on the mixed convex roof

    E-Print Network [OSTI]

    Dong Yang; Karol Horodecki; Michal Horodecki; Pawel Horodecki; Jonathan Oppenheim; Wei Song

    2009-07-23T23:59:59.000Z

    New measures of multipartite entanglement are constructed based on two definitions of multipartite information and different methods of optimizing over extensions of the states. One is a generalization of the squashed entanglement where one takes the mutual information of parties conditioned on the state's extension and takes the infimum over such extensions. Additivity of the multipartite squashed entanglement is proved for both versions of the multipartite information which turn out to be related. The second one is based on taking classical extensions. This scheme is generalized, which enables to construct measures of entanglement based on the {\\it mixed convex roof} of a quantity, which in contrast to the standard convex roof method involves optimization over all decompositions of a density matrix rather than just the decompositions into pure states. As one of the possible applications of these results we prove that any multipartite monotone is an upper bound on the amount of multipartite distillable key. The findings are finally related to analogous results in classical key agreement.

  15. International Rainwater Catchment Systems Conference, March 28April 4, 2011, Taiwan, R.O.C. NGUYEN-DEROCHE et al., 2011. Quality of roof harvested rainwater from houses in le-de-France area,

    E-Print Network [OSTI]

    Boyer, Edmond

    .O.C. NGUYEN-DEROCHE et al., 2011. Quality of roof harvested rainwater from houses in Île-de-France area, France. 1 Quality of roof harvested rainwater from houses in Île-de-France area, France. Thi Le Nhung microorganisms in the outside tanks. The difficulty to evaluate the microbial quality of roof- harvested

  16. RUNOFF QUALITY FROM ROOFING DURING EARLY LIFE Shirley E. Clark, Ph.D., P.E., D. WRE, Brett V. Long, Christina Y.S. Siu, Julia Spicher, Kelly A.

    E-Print Network [OSTI]

    Clark, Shirley E.

    1 RUNOFF QUALITY FROM ROOFING DURING EARLY LIFE Shirley E. Clark, Ph.D., P.E., D. WRE, Brett V through the use of retention and reuse of water on site. One opportunity for water harvesting is the roof and several organizations have provided guidance for roofing surfaces that are appropriate for harvesting

  17. B. Mobasher, S-Y.Chen, C. Young and S. D. Rajan, "Cost-Based Design Of Residential Steel Roof Systems: A Case Study", Structural Engineering and Mechanics 8:(2) pp.165-180,1999.

    E-Print Network [OSTI]

    Mobasher, Barzin

    B. Mobasher, S-Y.Chen, C. Young and S. D. Rajan, "Cost-Based Design Of Residential Steel Roof OF RESIDENTIAL STEEL ROOF SYSTEMS: A CASE STUDY S. D. Rajan 1 , B. Mobasher 2 , S-Y.Chen 3 and C. Young 3 The cost effectiveness of steel roof systems for residential buildings is becoming increasingly apparent

  18. Tracing the magmatic/hydrothermal transition in regional low-strain zones: The role of magma dynamics in strain localization at pluton roof, implications for intrusion-related gold

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    dynamics in strain localization at pluton roof, implications for intrusion-related gold deposits Eric features of a granite-pluton roof; large-scale dykes and a network of gold veins are intensively developed in this roof, recording a succession of mechanical instabilities. Our gravity survey underlines the presence

  19. SteamMaster: Steam System Analysis Software

    E-Print Network [OSTI]

    Wheeler, G.

    tool to facilitate the process. SteamMaster is based on an Excel spreadsheet with a Visual Basic interface to simplify system modeling and analysis. SteamMaster has many features and capabilities, including energy and cost savings calculations for five...

  20. Steam System Optimization : A Case Study

    E-Print Network [OSTI]

    Iordanova, N.; Venkatesan, V. V.; Calogero, M.

    perfonnance at higher ambient temperatures. The set point for shutdown of the compressors is 140?F and the oil temperature reached l36-140~ during the survey. Trouble free compressor operation is ensured when required temperatures are maintained... be justified by a high level of boiler utilization. Once installed, they are usually trouble-free and require little maintenance. It was proposed to install an economizer in the stack of the boilers to recover a portion of the heat that is carried away...

  1. Steam System Improvement: A Case Study

    E-Print Network [OSTI]

    Leigh, N.; Venkatesan, V. V.

    of 50 psig flash steam, which will otherwise be supplied through the PRV. The net annual saving will be about $15,300. 8. Compressor Cooling Air Recovery to Supply Hot Air to the Hood of Paper Machine #5 The paper mill operates two instrument air... compressors. The capacity of each compressor is 14,500 cfm. The compressors are air-cooled, and the cooling air is ejected into the atmosphere. The heat contained in the compressor cooling air can be categorized as waste heat, because it has a temperature...

  2. Savings in Steam Systems (A Case Study)

    E-Print Network [OSTI]

    DeBat, R.

    . Any changes that have been made to the tag number should be "written over" the old entry on the computer printout. This becomes the input to the computer. As each trap is tested, all strainers should be blown down for a couple of minutes to ensure... they are clean. Each isolation and bypass valve should be closed and ultrasonically checked for leakage. Every trap, valve, or strainer that has failed should be tagged for replacement or repair. A well-run steam trap management program will: ? Reduce...

  3. Steam System Improvements at a Manufacturing Plant 

    E-Print Network [OSTI]

    Compher, J.; Morcom, B.

    1999-01-01T23:59:59.000Z

    for more detailed information on boiler control upgrades were initiated. While reviewing steam trap options, NNFD was contacted by Dibert Valve & Fitting Company, which was marketing a new steam trap system that allowed easier testing and repair..., a detailed workscope for the boiler control upgrades, and a quote was obtained. After review by maintenance management and mechanics, orders for both the boiler control package and the steam trap system's components were placed. BOILER CONTROLS...

  4. Savings in Steam Systems (A Case Study) 

    E-Print Network [OSTI]

    DeBat, R.

    2001-01-01T23:59:59.000Z

    of the process or the plant. In the power industry, the term Distributed Control System (DCS) is generally applied to the system that implements boiler control and data acquisition functions of the power plant. A state-of-the-art DCS is typically composed... application in a boiler house operation typically covers the following areas: ? Boiler controls, including the combustion (firing rate), furnace draft, steam temperature, and feedwater control loops; ? Burner control; ? Control loops in the plant...

  5. Steam System Optimization : A Case Study 

    E-Print Network [OSTI]

    Iordanova, N.; Venkatesan, V. V.; Calogero, M.

    2002-01-01T23:59:59.000Z

    to the required levels for different consumers. ABC Plant utilizes steam in two ways: ? indirect use, returning the condensate after process heating, hot water generation and comfort heating. ? direct use in XXX moisturizers, XXX steamers, XXX water tanks...

  6. Steam System Survey Guide | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33Frequently AskedEnergyIssues DOE's NuclearSpurring

  7. Steam System Modeler | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreakingMayDepartment of Staffing Model5ThomasEnergyReceives Energy Assessment |Steam

  8. Steam-system upgrades | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro Industries Pvt LtdShawangunk,SoutheastSt. Francis(RedirectedStarr||Ste. Genevieveupgrades Jump

  9. Steam System Survey Guide | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn'tOriginEducationVideo »UsageSecretaryVideosSpringoutAPBF-DEC NOxBestPractices SteamOffice

  10. Airtightness Results of Roof-Only Air Sealing Strategies on 1-1/2 Story Homes in Cold Climates

    SciTech Connect (OSTI)

    Ojczyk, C.; Murry, T.; Mosiman, G.

    2014-07-01T23:59:59.000Z

    In this second study on solutions to ice dams in 1-1/2 story homes, five test homes located in both cold and very cold climates were analyzed for air leakage reduction rates following modifications by independent contractors on owner-occupied homes. The reason for choosing this house type was they are very common in our area and very difficult to air seal and insulate effectively. Two projects followed a roof-only Exterior Thermal Moisture Management System (ETMMS) process. One project used an interior-only approach to roof air sealing and insulation. The remaining two projects used a deep energy retrofit approach for whole house (foundation wall, above grade wall, roof) air leakage and heat loss reduction. All were asked to provide information regarding project goals, process, and pre and post-blower door test results. Additional air leakage reduction data was provided by several NorthernSTAR Building America industry partners for interior-applied, roof-only modifications on 1-1/2 story homes. The data represents homes in the general market as well as homes that were part of the state of Minnesota weatherization program. A goal was to compare exterior air sealing methods with interior approaches. This pool of data enabled us to compare air tightness data from over 220 homes using similar air seal methods.

  11. Comparison of Software Models for Energy Savings from Cool Roofs Joshua New, Oak Ridge National Laboratory (United States)

    E-Print Network [OSTI]

    Tennessee, University of

    , multiple substrate types, and insulation levels. A base case and energy-efficient alternative canComparison of Software Models for Energy Savings from Cool Roofs Joshua New, Oak Ridge National Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors

  12. 1. Detect ground faults in PV arrays mounted on the roofs of 2. Interrupt the fault current

    E-Print Network [OSTI]

    Johnson, Eric E.

    1. Detect ground faults in PV arrays mounted on the roofs of dwellings 2. Interrupt the fault current 3. Indicate that a ground fault had occurred 4. Disconnect the faulted part of the PV array 5. "Crowbar" (short-circuit) the PV array The original GFPD prototype was developed in two versions that were

  13. 1. Large Scale Climate Simulator (Building 3144) The LSCS tests roof and/or attic assemblies weighing up to

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    Envelope 1. Large Scale Climate Simulator (Building 3144) The LSCS tests roof and/or attic assemblies weighing up to 9000 kg (10 tons) and as high as 1.83 m (6 ft.) under any inhabited climatic and outdoors but also captures a wide range of secondary metrics. 2. Rotatable Guarded Hot Box (Building 3144

  14. Project Overcoat - An Exploration of Exterior Insulation Strategies for 1-1/2-Story Roof Applications in Cold Climates

    SciTech Connect (OSTI)

    Ojczyk, C.; Mosiman, G.; Huelman, P.; Schirber, T.; Yost, P.; Murry, T.

    2013-04-01T23:59:59.000Z

    The development of an alternative method to interior-applied insulation strategies or exterior applied 'band-aids' such as heat tapes and ice belts may help reduce energy needs of millions of 1-1/2 story homes while reducing the risk of ice dam formation. A potential strategy for energy improvement of the roof is borrowed from new construction best practices: Here an 'overcoat' of a continuous air, moisture, and thermal barrier is applied on the outside of the roof structure for improved overall performance. The continuous insulation of this approach facilitates a reduction in thermal bridging which could further reduce energy consumption and bring existing homes closer to meeting the Building America goals for energy reduction. Research favors an exterior approach to deep energy retrofits and ice dam prevention in existing homes. The greatest amount of research focuses on whole house deep energy retrofits leaving a void in roof-only applications. The research is also void of data supporting the hygrothermal performance, durability, constructability, and cost of roof-only exterior overcoat strategies. Yet, contractors interviewed for this report indicate an understanding that exterior approaches are most promising for mitigating ice dams and energy loss and are able to sell these strategies to homeowners.

  15. Roof-top solar energy potential under performance-based building energy codes: The case of Spain

    SciTech Connect (OSTI)

    Izquierdo, Salvador; Montanes, Carlos; Dopazo, Cesar; Fueyo, Norberto [Fluid Mechanics Group, University of Zaragoza and LITEC (CSIC), Maria de Luna 3, 50018 Zaragoza (Spain)

    2011-01-15T23:59:59.000Z

    The quantification at regional level of the amount of energy (for thermal uses and for electricity) that can be generated by using solar systems in buildings is hindered by the availability of data for roof area estimation. In this note, we build on an existing geo-referenced method for determining available roof area for solar facilities in Spain to produce a quantitative picture of the likely limits of roof-top solar energy. The installation of solar hot water systems (SHWS) and photovoltaic systems (PV) is considered. After satisfying up to 70% (if possible) of the service hot water demand in every municipality, PV systems are installed in the remaining roof area. Results show that, applying this performance-based criterion, SHWS would contribute up to 1662 ktoe/y of primary energy (or 68.5% of the total thermal-energy demand for service hot water), while PV systems would provide 10 T W h/y of electricity (or 4.0% of the total electricity demand). (author)

  16. Distribution and dynamics of entanglement in high-dimensional quantum systems using convex-roof extended negativity

    E-Print Network [OSTI]

    Soojoon Lee; Jeong San Kim; Barry C. Sanders

    2010-06-03T23:59:59.000Z

    We develop theories of entanglement distribution and of entanglement dynamics for qudit systems, which incorporate previous qubit formulations. Using convex-roof extended negativity, we generalize previous qubit results for entanglement distribution with isotropic states and for entanglement dynamics with the depolarizing channel, and we establish a relation between these two types of entanglement networks.

  17. Distribution and dynamics of entanglement in high-dimensional quantum systems using convex-roof extended negativity

    E-Print Network [OSTI]

    Lee, Soojoon; Sanders, Barry C

    2010-01-01T23:59:59.000Z

    We develop theories of entanglement distribution and of entanglement dynamics for qudit systems, which incorporate previous qubit formulations. Using convex-roof extended negativity, we generalize previous qubit results for entanglement distribution with isotropic states and for entanglement dynamics with the depolarizing channel, and we establish a relation between these two types of entanglement networks.

  18. Light Properties Light travels at the speed of light `c'

    E-Print Network [OSTI]

    Mojzsis, Stephen J.

    LIGHT!! #12;Light Properties Light travels at the speed of light `c' C = 3 x 108 m/s Or 190,000 miles/second!! Light could travel around the world about 8 times in one second #12;What is light?? Light is a "wave packet" A photon is a "light particle" #12;Electromagnetic Radiation and You Light is sometimes

  19. Numerical evaluation of convex-roof entanglement measures with applications to spin rings

    E-Print Network [OSTI]

    Röthlisberger, Beat; Loss, Daniel

    2009-01-01T23:59:59.000Z

    We present two ready-to-use numerical algorithms to evaluate convex-roof extensions of arbitrary pure-state entanglement monotones. Their implementation leaves the user merely with the task of calculating derivatives of the respective pure-state measure. We provide numerical tests of the algorithms and demonstrate their good convergence properties. We further employ them in order to investigate the entanglement in particular few-spins systems at finite temperature. Namely, we consider ferromagnetic Heisenberg exchange-coupled spin-1/2 rings subject to an inhomogeneous in-plane field geometry obeying full rotational symmetry around the axis perpendicular to the ring through its center. We demonstrate that highly entangled states can be obtained in these systems at sufficiently low temperatures and by tuning the strength of a magnetic field configuration to an optimal value which is identified numerically.

  20. libCreme: An optimization library for evaluating convex-roof entanglement measures

    E-Print Network [OSTI]

    Röthlisberger, Beat; Loss, Daniel

    2011-01-01T23:59:59.000Z

    We present the software library libCreme which we have previously used to successfully calculate convex-roof entanglement measures of mixed quantum states appearing in realistic physical systems. Evaluating the amount of entanglement in such states is in general a non-trivial task requiring to solve a highly non-linear complex optimization problem. The algorithms provided here are able to achieve to do this for a large and important class of entanglement measures. The library is mostly written in the Matlab programming language, but is fully compatible to the free and open-source Octave platform. Some inefficient subroutines are written in C/C++ for better performance. This manuscript discusses the most important theoretical concepts and workings of the algorithms, focussing on the actual implementation and usage within the library. Detailed examples in the end should make it easy for the user to apply libCreme to specific problems.

  1. Numerical evaluation of convex-roof entanglement measures with applications to spin rings

    SciTech Connect (OSTI)

    Roethlisberger, Beat; Lehmann, Joerg; Loss, Daniel [Department of Physics, University of Basel, Klingelbergstrasse 82, CH-4056 Basel (Switzerland)

    2009-10-15T23:59:59.000Z

    We present two ready-to-use numerical algorithms to evaluate convex-roof extensions of arbitrary pure-state entanglement monotones. Their implementation leaves the user merely with the task of calculating derivatives of the respective pure-state measure. We provide numerical tests of the algorithms and demonstrate their good convergence properties. We further employ them in order to investigate the entanglement in particular few-spins systems at finite temperature. Namely, we consider ferromagnetic Heisenberg exchange-coupled spin-(1/2) rings subject to an inhomogeneous in-plane field geometry obeying full rotational symmetry around the axis perpendicular to the ring through its center. We demonstrate that highly entangled states can be obtained in these systems at sufficiently low temperatures and by tuning the strength of a magnetic field configuration to an optimal value which is identified numerically.

  2. libCreme: An optimization library for evaluating convex-roof entanglement measures

    E-Print Network [OSTI]

    Beat Röthlisberger; Jörg Lehmann; Daniel Loss

    2011-07-22T23:59:59.000Z

    We present the software library libCreme which we have previously used to successfully calculate convex-roof entanglement measures of mixed quantum states appearing in realistic physical systems. Evaluating the amount of entanglement in such states is in general a non-trivial task requiring to solve a highly non-linear complex optimization problem. The algorithms provided here are able to achieve to do this for a large and important class of entanglement measures. The library is mostly written in the Matlab programming language, but is fully compatible to the free and open-source Octave platform. Some inefficient subroutines are written in C/C++ for better performance. This manuscript discusses the most important theoretical concepts and workings of the algorithms, focussing on the actual implementation and usage within the library. Detailed examples in the end should make it easy for the user to apply libCreme to specific problems.

  3. Entanglement monogamy of multipartite higher-dimensional quantum systems using convex-roof extended negativity

    E-Print Network [OSTI]

    Kim, Jeong San; Sanders, Barry C

    2008-01-01T23:59:59.000Z

    We propose replacing concurrence by convex-roof extended negativity (CREN) for studying monogamy of entanglement (MoE). We show that all proven MoE relations using concurrence can be rephrased in terms of CREN. Furthermore we show that higher-dimensional (qudit) extensions of MoE in terms of CREN are not disproven by any of the counterexamples used to disprove qudit extensions of MoE in terms of concurrence. We further test the CREN version of MoE for qudits by considering fully or partially coherent mixtures of a qudit W-class state with the vacuum and show that the CREN version of MoE for qudits is satisfied in this case as well. The CREN version of MoE for qudits is thus a strong conjecture with no obvious counterexamples.

  4. Numerical evaluation of convex-roof entanglement measures with applications to spin rings

    E-Print Network [OSTI]

    Beat Röthlisberger; Jörg Lehmann; Daniel Loss

    2009-05-19T23:59:59.000Z

    We present two ready-to-use numerical algorithms to evaluate convex-roof extensions of arbitrary pure-state entanglement monotones. Their implementation leaves the user merely with the task of calculating derivatives of the respective pure-state measure. We provide numerical tests of the algorithms and demonstrate their good convergence properties. We further employ them in order to investigate the entanglement in particular few-spins systems at finite temperature. Namely, we consider ferromagnetic Heisenberg exchange-coupled spin-1/2 rings subject to an inhomogeneous in-plane field geometry obeying full rotational symmetry around the axis perpendicular to the ring through its center. We demonstrate that highly entangled states can be obtained in these systems at sufficiently low temperatures and by tuning the strength of a magnetic field configuration to an optimal value which is identified numerically.

  5. Entanglement monogamy of multipartite higher-dimensional quantum systems using convex-roof extended negativity

    E-Print Network [OSTI]

    Jeong San Kim; Anirban Das; Barry C. Sanders

    2008-11-13T23:59:59.000Z

    We propose replacing concurrence by convex-roof extended negativity (CREN) for studying monogamy of entanglement (MoE). We show that all proven MoE relations using concurrence can be rephrased in terms of CREN. Furthermore we show that higher-dimensional (qudit) extensions of MoE in terms of CREN are not disproven by any of the counterexamples used to disprove qudit extensions of MoE in terms of concurrence. We further test the CREN version of MoE for qudits by considering fully or partially coherent mixtures of a qudit W-class state with the vacuum and show that the CREN version of MoE for qudits is satisfied in this case as well. The CREN version of MoE for qudits is thus a strong conjecture with no obvious counterexamples.

  6. Moisture effects in low-slope roofs: Drying rates after water addition with various vapor retarders

    SciTech Connect (OSTI)

    Pedersen, C.R. [Technical Univ. of Denmark, Lyngby (Denmark); Petrie, T.W. [Marquette Univ., Milwaukee, WI (United States). Dept. of Mechanical Engineering; Courville, G.E.; Desjarlais, A.O.; Childs, P.W.; Wilkes, K.E. [Oak Ridge National Lab., TN (United States)

    1992-10-01T23:59:59.000Z

    Tests have been conducted in the Large Scale Climate Simulator (LSCS) of the US. Building Envelope Research Center at the Oak Ridge National Laboratory (ORNL) to investigate downward drying rates of various unvented, low-slope roof systems. A secondary objective was to study heat flow patterns so as to understand how to control latent heat effects on impermeable heat flux transducers. Nine test sections were tested simultaneously. The sections had a p deck above fibrous-glass insulation and were examples of cold-deck systems. These five sections had various vapor retarder systems on a gypsum board ceiling below the insulation. The other four sections had a lightweight insulating concrete deck below expanded polystyrene insulation and the same vapor retarder systems, and were examples of warm-deck systems. The cold-deck systems had materials that were relatively permeable to water vapor, while the materials in the warm-deck systems were less permeable. All test sections were topped by an impermeable roofing membrane. The test sections were instrumented with thermocouples between all layers and with small heat flux transducers at the bottom and top of the fibrous-glass insulation and in the middle of the expanded polystyrene insulation. Two different kinds of moisture probes were used to qualitatively monitor the movement of the moisture. The heat flux measurements showed that heat conduction dominates the system using impermeable insulation materials, with only a slight increase due to increased thermal conductivity of wet expanded polystyrene. There was significant transfer of latent heat in the test sections with permeable insulation, causing the peak heat fluxes to increase by as much as a factor of two. With temperatures imposed that are typical of summer days, latent heat transfer associated with condensation and evaporation of moisture in the test sections was measured to be as important as the heat transfer by conduction.

  7. Smart Lighting Controller!! Smart lighting!

    E-Print Network [OSTI]

    Anderson, Betty Lise

    1! Smart Lighting Controller!! #12;2! Smart lighting! No need to spend energy lighting the room if://blogs.stthomas.edu/realestate/2011/01/24/residential-real-estate-professionals-how-do-you- develop feedback! There is a connection between the output and the input! Therefore forces inputs to same voltage

  8. Design, development and validation of a training system for roof bolt equipment operators. Open file report, 21 September 1978-10 April 1982

    SciTech Connect (OSTI)

    Hinton, W.M. Jr.; Menzer, G.W.; Reilly, R.E.; Baker, R.M.

    1982-04-10T23:59:59.000Z

    This report describes the approach, procedures, and results of a program to develop training materials for roof bolter operators. The objective of the program was to design and produce a training sequence which would prepare roof bolter trainees for job performance. Data were collected and analyzed using the general procedures of Instructional Systems Development (ISD). Input data came from previous roof bolter training analysis program. These data were expanded and structured through a series of ISD steps: objectives hierarchies, media selection, syllabus, lesson specifications, and training materials development. The resulting program consisted of an ordered sequence of 15 lessons. The media mix for the 15 lessons included lectures, slide-tape lessons, and hands-on instruction using operational roof bolters. Contents of all lessons were reviewed and approved by the Bureau of Mines.

  9. Cerenkov Light

    ScienceCinema (OSTI)

    Slifer, Karl

    2014-05-22T23:59:59.000Z

    The bright blue glow from nuclear reactors is Cerenkov light. Karl Slifer describes how nuclear physicists can use this phenomenon to study the nucleus of the atom.

  10. Cerenkov Light

    SciTech Connect (OSTI)

    Slifer, Karl

    2013-06-13T23:59:59.000Z

    The bright blue glow from nuclear reactors is Cerenkov light. Karl Slifer describes how nuclear physicists can use this phenomenon to study the nucleus of the atom.

  11. Lighting Renovations

    Broader source: Energy.gov [DOE]

    When undertaking a lighting renovation in a Federal building, daylighting is the primary renewable energy opportunity. Photovoltaics (PV) also present an excellent opportunity. While this guide...

  12. DYNAMIC THERMALLY-DISCONNECTED BUILDING ENVELOPES A NEW PARADIGM FOR WALLS AND ROOFS IN LOW ENERGY BUILDINGS

    SciTech Connect (OSTI)

    Miller, William A [ORNL] [ORNL; Kosny, Jan [ORNL] [ORNL; Zaltash, Abdolreza [ORNL] [ORNL

    2010-01-01T23:59:59.000Z

    This paper describes numerical and experimental analysis of a novel design concept. Traditionally the thermal design of building envelope assemblies is based on a static energy flow. However, building envelopes are subject to varying environmental conditions. This mismatch between the steady-state principles used in the design of roofs and walls and their dynamic operation results in relatively low thermal efficiency. Design work in support of the development of zero energy houses showed that conventional insulations may not be the most cost effective energy solution. Testing conducted on several strategies to thermally-disconnect wall and roof components showed 70% to 90% reductions in peak hour loads as compared to conventional building practice.

  13. Using Cool Roofs to Reduce Energy Use, Greenhouse Gas Emissions, and Urban Heat-island Effects: Findings from an India Experiment

    SciTech Connect (OSTI)

    Akbari, Hashem; Xu, Tengfang; Taha, Haider; Wray, Craig; Sathaye, Jayant; Garg, Vishal; Tetali, Surekha; Babu, M. Hari; Reddy, K. Niranjan

    2011-05-25T23:59:59.000Z

    Cool roofs, cool pavements, and urban vegetation reduce energy use in buildings, lower local air pollutant concentrations, and decrease greenhouse gas emissions from urban areas. This report summarizes the results of a detailed monitoring project in India and related simulations of meteorology and air quality in three developing countries. The field results quantified direct energy savings from installation of cool roofs on individual commercial buildings. The measured annual energy savings potential from roof-whitening of previously black roofs ranged from 20-22 kWh/m2 of roof area, corresponding to an air-conditioning energy use reduction of 14-26% in commercial buildings. The study estimated that typical annual savings of 13-14 kWh/m2 of roof area could be achieved by applying white coating to uncoated concrete roofs on commercial buildings in the Metropolitan Hyderabad region, corresponding to cooling energy savings of 10-19%. With the assumption of an annual increase of 100,000 square meters of new roof construction for the next 10 years in the Metropolitan Hyderabad region, the annual cooling energy savings due to whitening concrete roof would be 13-14 GWh of electricity in year ten alone, with cumulative 10-year cooling energy savings of 73-79 GWh for the region. The estimated savings for the entire country would be at least 10 times the savings in Hyderabad, i.e., more than 730-790 GWh. We estimated that annual direct CO2 reduction associated with reduced energy use would be 11-12 kg CO2/m2 of flat concrete roof area whitened, and the cumulative 10-year CO2 reduction would be approximately 0.60-0.65 million tons in India. With the price of electricity estimated at seven Rupees per kWh, the annual electricity savings on air-conditioning would be approximately 93-101 Rupees per m2 of roof. This would translate into annual national savings of approximately one billion Rupees in year ten, and cumulative 10-year savings of over five billion Rupees for cooling energy in India. Meteorological simulations in this study indicated that a reduction of 2C in air temperature in the Hyderabad area would be likely if a combination of increased surface albedo and vegetative cover are used as urban heat-island control strategies. In addition, air-temperature reductions on the order of 2.5-3.5C could be achieved if moderate and aggressive heat-island mitigation measures are adopted, respectively. A large-scale deployment of mitigation measures can bring additional indirect benefit to the urban area. For example, cooling outside air can improve the efficiency of cooling systems, reduce smog and greenhouse gas (GHG) emissions, and indirectly reduce pollution from power plants - all improving environmental health quality. This study has demonstrated the effectiveness of cool-roof technology as one of the urban heat-island control strategies for the Indian industrial and scientific communities and has provided an estimate of the national energy savings potential of cool roofs in India. These outcomes can be used for developing cool-roof building standards and related policies in India. Additional field studies, built upon the successes and lessons learned from this project, may be helpful to further confirm the scale of potential energy savings from the application of cooler roofs in various regions of India. In the future, a more rigorous meteorological simulation using urbanized (meso-urban) meteorological models should be conducted, which may produce a more accurate estimate of the air-temperature reductions for the entire urban area.

  14. The technical viability of alternative blowing agents in polyisocyanurate roof insulation

    SciTech Connect (OSTI)

    McElroy, D.L.; Graves, R.S.; Weaver, F.J.; Yarbrough, D.W.

    1990-01-01T23:59:59.000Z

    This paper is a progress report on the initial results of laboratory test on a set of prototypical, experimental, polyisocyanurate (PIR) laminate boardstock produced to evaluate the viability of alternative hydrochlorofluorocarbons (HCFCs) as blowing agents. All boardstock was produced from the same formulation and was not optimized for thermal performance. Boardstock made in the future may differ in performance from this set. Thermal resistance values are reported for PIR boards prepared with CFC-11, HCFC-123, HCFC-141b, and two blends of HCFC-123 and HCFC-141b. The primary purpose of the laboratory tests is to answer a key question: will foams produced with the alternative blowing agents yield the same outstanding thermal properties obtained with CFC-11 The CFC problem is enormous. Reductions in the production of CFC-11 and CFC-12 may lead to less efficient substitutes and increase annual US energy consumption for building applications alone by one (10{sup 15}Btu) or more (1). The current effort is a cooperative industry/government program to avoid this undesirable effect by establishing the viability of alternative blowing agents. The research project for CFC alternatives resulted from two workshops that involved participants from industry, government, and academia (2). At the initial workshop the participants prioritized 29 research projects of a CFC research menu. The second workshop focused on a single cooperative project, the long-term performance of substitute insulations containing HCFC-123 and HCFC-141b for roofing applications. 20 refs., 5 figs., 7 tabs.

  15. Soiling of building envelope surfaces and its effect on solar reflectance - Part II: Development of an accelerate aging method for roofing materials

    SciTech Connect (OSTI)

    Sleiman, Mohamad; Kirchstetter, Thomas W.; Berdahl, Paul; Gilbert, Haley; Quelen, Sarah; Marlot, Lea; Preble, Chelsea; Chen, Sharon; Montalbano, Amadine; Rosseler, Olivier; Akbari, Hashem; Levinson, Ronnen; Destaillats, Hugo

    2013-11-18T23:59:59.000Z

    Highly reflective roofs can decrease the energy required for building air conditioning, help mitigate the urban heat island effect, and slow global warming. However, these benefits are diminished by soiling and weathering processes that reduce the solar reflectance of most roofing materials. Soiling results from the deposition of atmospheric particulate matter and the growth of microorganisms, each of which absorb sunlight. Weathering of materials occurs with exposure to water, sunlight, and high temperatures. This study developed an accelerated aging method that incorporates features of soiling and weathering. The method sprays a calibrated aqueous soiling mixture of dust minerals, black carbon, humic acid, and salts onto preconditioned coupons of roofing materials, then subjects the soiled coupons to cycles of ultraviolet radiation, heat and water in a commercial weatherometer. Three soiling mixtures were optimized to reproduce the site-specific solar spectral reflectance features of roofing products exposed for 3 years in a hot and humid climate (Miami, Florida); a hot and dry climate (Phoenix, Arizona); and a polluted atmosphere in a temperate climate (Cleveland, Ohio). A fourth mixture was designed to reproduce the three-site average values of solar reflectance and thermal emittance attained after 3 years of natural exposure, which the Cool Roof Rating Council (CRRC) uses to rate roofing products sold in the US. This accelerated aging method was applied to 25 products?single ply membranes, factory and field applied coatings, tiles, modified bitumen cap sheets, and asphalt shingles?and reproduced in 3 days the CRRC's 3-year aged values of solar reflectance. This accelerated aging method can be used to speed the evaluation and rating of new cool roofing materials.

  16. Light Computing

    E-Print Network [OSTI]

    Gordon Chalmers

    2006-10-13T23:59:59.000Z

    A configuration of light pulses is generated, together with emitters and receptors, that allows computing. The computing is extraordinarily high in number of flops per second, exceeding the capability of a quantum computer for a given size and coherence region. The emitters and receptors are based on the quantum diode, which can emit and detect individual photons with high accuracy.

  17. Evaluation of the thermal resistance of a roof-mounted multi-reflective radiant barrier for tropical and humid conditions: Experimental study from field measurements

    E-Print Network [OSTI]

    Miranville, Frédéric; Guichard, Stéphane; Boyer, Harry; Praene, Jean Philippe; Bigot, Dimitri

    2012-01-01T23:59:59.000Z

    This paper deals with the experimental evaluation of a roof-mounted multi-reflective radiant barrier (MRRB), installed according to the state of the art, on a dedicated test cell. An existing experimental device was completed with a specific system for the regulation of the airflow rate in the upper air layer included in a typical roof from Reunion Island. Several experimental sequences were conducted to determine the thermal resistance of the roof according to several parameters and following a specific method. The mean method, well known in international standards (ISO 9869 - 1994) for the determination of the thermal resistance using dynamic data, was used. The method was implemented in a building simulation code in order to allow the determination of the thermal indicator automatically. Experimental results are proposed according to different seasonal periods and for different values of the airflow rate in the upper air layer

  18. Evaluation of the thermal resistance of a roof-mounted multi-reflective radiant barrier for tropical and humid conditions: Experimental study from field measurements

    E-Print Network [OSTI]

    Frédéric Miranville; Ali Hamada Fakra; Stéphane Guichard; Harry Boyer; Jean Philippe Praene; Dimitri Bigot

    2012-12-19T23:59:59.000Z

    This paper deals with the experimental evaluation of a roof-mounted multi-reflective radiant barrier (MRRB), installed according to the state of the art, on a dedicated test cell. An existing experimental device was completed with a specific system for the regulation of the airflow rate in the upper air layer included in a typical roof from Reunion Island. Several experimental sequences were conducted to determine the thermal resistance of the roof according to several parameters and following a specific method. The mean method, well known in international standards (ISO 9869 - 1994) for the determination of the thermal resistance using dynamic data, was used. The method was implemented in a building simulation code in order to allow the determination of the thermal indicator automatically. Experimental results are proposed according to different seasonal periods and for different values of the airflow rate in the upper air layer.

  19. Residential Lighting

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's PossibleRadiation Protection Technical squestionnairesquestionnaires AgreementLighting

  20. Lighting Inventory Lighting Theatre and Drama

    E-Print Network [OSTI]

    Indiana University

    Lighting Inventory Lighting Theatre and Drama Description Totals R.Halls Wells- Metz Light ERS ETC SourceFour 25 25 50 degree ERS Strand Lighting 64 14 24 12 14 36 degree ERS ETC Source Four 15 15 36 degree ERS Strand Lighting 124 60 58 2 4 26 degree ERS ETC SourceFour 2 2 26 degree ERS Strand

  1. LED Lighting Basics

    Broader source: Energy.gov [DOE]

    Light-Emitting diodes (LEDs) efficiently produce light in a fundamentally different way than any legacy or traditional source of light.

  2. Light Source

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville PowerCherries 82981-1cnHigh SchoolIn12electron 9 5Let us count theLienertLift Forces in a Light

  3. Become One In A Million: Partnership Updates. Million Solar Roofs and Interstate Renewable Energy Council Annual Meeting, Washington, D.C., October 2005

    SciTech Connect (OSTI)

    Tombari, C.

    2005-09-01T23:59:59.000Z

    The U.S. Department of Energy's Million Solar Roofs Initiative (MSR) is a unique public-private partnership aimed at overcoming market barriers for photovoltaics (PV), solar water heating, transpired solar collectors, solar space heating and cooling, and pool heating. This report contains annual progress reports from 866 partners across the United States.

  4. Rainwater harvesting systems that collect and convey rain-water from roofs to storage tanks are often the best or only

    E-Print Network [OSTI]

    Polz, Martin

    PROBLEM Rainwater harvesting systems that collect and convey rain- water from roofs to storage-yearrecord Rigorous analysis of rainwater harvesting system design can improve reliability and water quality CEE-yield of the rainwater harvesting systems, defining reliability as days per year on which the community's water de- mand

  5. Cost Analysis of Roof-Only Air Sealing and Insulation Strategies on 1 1/2-Story Homes in Cold Climates

    SciTech Connect (OSTI)

    Ojczyk, C.

    2014-12-01T23:59:59.000Z

    The External Thermal and Moisture Management System (ETMMS), typically seen in deep energy retrofits, is a valuable approach for the roof-only portions of existing homes, particularly the 1 1/2-story home. It is effective in reducing energy loss through the building envelope, improving building durability, reducing ice dams, and providing opportunities to improve occupant comfort and health.

  6. October 2012 | National Nuclear Security Administration

    National Nuclear Security Administration (NNSA)

    The light-colored cool roofs reflect more heat than darker roofs emitting absorbed solar radiation back into the atmosphere. By doing so, the roof covering remains relatively...

  7. Sustainable Office Lighting Options

    E-Print Network [OSTI]

    Massachusetts at Amherst, University of

    Sustainable Office Lighting Options Task Lighting: Task lighting is a localized method of lighting a workspace so that additional, unnecessary lighting is eliminated, decreasing energy usage and costs. Illumination levels in the targeted work areas are higher with task lighting than with the ambient levels

  8. Plasma lighting, fiber optics, and daylight collectors: Toward the next revolution in high-efficiency illumination

    SciTech Connect (OSTI)

    Audin, L. [Columbia Univ., New York, NY (United States)

    1995-06-01T23:59:59.000Z

    Combining three recently marketed innovations may provide the next revolution in illumination, making many other recent advances eventually obsolete. The first is plasma lighting, pioneered by Fusion Lighting Inc. of Rockville, Maryland, and first commercially applied by Hutchins International Ltd. of Mississauga, Ontario. This microwave-generated light source yields very high-quality light with efficacies at or beyond high intensity discharge (HID) lamps. The source uses no mercury, thus eliminating lamp disposal problems, and has no cathode, thereby providing very long lamp life. Using no phosphors, it also has very short start and re-strike periods, and is dimmable. The second innovation is in the distribution of light. Commercial developments in fiber optics and light guides now provide products that transfer light from a remote point and distribute it like standard light fixtures. Advances in fiber optic communications and applications to decorative lighting have supplied relatively economical systems for mounting and directing light from both electric light sources and the sun. The third advance is a result of efforts to harness daylight. Unlike architectural daylighting that directs sunlight into perimeter areas through glazing, daylight collectors are roof-mounted devices that supply light to interior and underground spaces through hollow columns and open chases. Aided by improvements and cost reductions in sun-tracking (i.e., heliostatic) controls that capture and concentrate sunlight, such collectors offer a source of free light to locations that might otherwise never receive it. When combined together, these three options could offer a centralized building lighting system that pipes lumens to distribution devices replacing many existing lamps and fixtures.

  9. Evaluation of Vegetative Roofs' Performance on Energy Consumption in Hot and Humid Climates

    E-Print Network [OSTI]

    Anderson, J.; Azarbayjani, M.

    with Building (6) is that it is located in (Florida), whereas the other buildings are located in cold climates (Maryland, New York, and south Texas). In hot climates most of the energy consumption is used for the air-conditioning of the buildings..., whereas in cold climates most of the energy is used for heating the buildings. However, it could be argued that it is more energy consuming to cool a space than to heat it. This is attributed to the fact that there is heat dissipation from light...

  10. Lighting Options for Homes.

    SciTech Connect (OSTI)

    Baker, W.S.

    1991-04-01T23:59:59.000Z

    This report covers many aspects of various lighting options for homes. Types of light sources described include natural light, artificial light, incandescent lamps, fluorescent lamps, and high intensity discharge lamps. A light source selection guide gives the physical characteristics of these, design considerations, and common applications. Color, strategies for efficient lighting, and types of lighting are discussed. There is one section giving tips for various situations in specific rooms. Rooms and types of fixtures are shown on a matrix with watts saved by using the recommended type lighting for that room and room location. A major emphasis of this report is saving energy by utilizing the most suitable, recommended lighting option. (BN)

  11. Mobile lighting apparatus

    DOE Patents [OSTI]

    Roe, George Michael; Klebanoff, Leonard Elliott; Rea, Gerald W; Drake, Robert A; Johnson, Terry A; Wingert, Steven John; Damberger, Thomas A; Skradski, Thomas J; Radley, Christopher James; Oros, James M; Schuttinger, Paul G; Grupp, David J; Prey, Stephen Carl

    2013-05-14T23:59:59.000Z

    A mobile lighting apparatus includes a portable frame such as a moveable trailer or skid having a light tower thereon. The light tower is moveable from a stowed position to a deployed position. A hydrogen-powered fuel cell is located on the portable frame to provide electrical power to an array of the energy efficient lights located on the light tower.

  12. Light disappears rapidly (exponentially)

    E-Print Network [OSTI]

    Kudela, Raphael M.

    #12;#12;#12;#12;Light disappears rapidly (exponentially) with depth At the same time, the color of the light shifts #12;#12;#12;#12;· Euphotic zone ­ plentiful light ­ 0-100 m (about) · Dysphotic zone ­ very, very little light ­ 100-1000 m (about) · Aphotic zone ­ no light ­ below 1000 m #12;Sunlight in Water

  13. New Light Sources for Tomorrow's Lighting Designs

    E-Print Network [OSTI]

    Krailo, D. A.

    can ever be saved on that monthly energy bill. During the past several years, many new light sources have been developed and introduced. These product introductions have not been limited to anyone lamp type, but instead may be found in fila ment..., fluorescent and high intensity discharge lamp families. Man , ufacturers of light sources have two basic goals for new product development. These goals are high efficiency lighting and improved colo'r rendering properties. High efficiency lighting may take...

  14. EK101 Engineering Light Smart Lighting

    E-Print Network [OSTI]

    Bifano, Thomas

    EK101 Engineering Light Smart Lighting Homework for 9/10 1. Make an estimate (using if the patent is granted.) 3. What is a lumen? A lux? How are the two related? How would you use a lux meter, (Lux, Lumens/m2) Luminous Flux: Perceivable light power from a source, (Lumens) Use the lux meter

  15. Specific light in sculpture

    E-Print Network [OSTI]

    Powell, John William

    1989-01-01T23:59:59.000Z

    Specific light is defined as light from artificial or altered natural sources. The use and manipulation of light in three dimensional sculptural work is discussed in an historic and contemporary context. The author's work ...

  16. The Impact of Above-Sheathing Ventilation on the Thermal and Moisture Performance of Steep-Slope Residential Roofs and Attics

    E-Print Network [OSTI]

    Miller, W.; Karagiozis, A.; Wilson, J.

    2006-01-01T23:59:59.000Z

    THE IMPACT OF ABOVE-SHEATHING VENTILATION ON THE THERMAL AND MOISTURE PERFORMANCE OF STEEP-SLOPE RESIDENTIAL ROOFS AND ATTICS William (Bill) Miller Research Scientist Oak Ridge National Laboratory Oak Ridge, Tennessee Joe Wilson Product... with and without infrared blocking color pigments (IrBCPs) and with and without above-sheathing ventilation. The combination of increased solar reflectance and above-sheathing ventilation reduced the heat flow penetrating the attic floor by 70% as compared...

  17. Performance of powder-filled evacuated panel insulation in a manufactured home roof cavity: Tests in the Large Scale Climate Simulator

    SciTech Connect (OSTI)

    Petrie, T.W.; Kosny, J.; Childs, P.W.

    1996-03-01T23:59:59.000Z

    A full-scale section of half the top of a single-wide manufactured home has been studied in the Large Scale Climate Simulator (LSCS) at the Oak Ridge National Laboratory. A small roof cavity with little room for insulation at the eaves is often the case with single-wide units and limits practical ways to improve thermal performance. The purpose of the current tests was to obtain steady-state performance data for the roof cavity of the manufactured home test section when the roof cavity was insulated with fiberglass batts, blown-in rock wool insulation or combinations of these insulations and powder-filled evacuated panel (PEP) insulation. Four insulation configurations were tested: (A) a configuration with two layers of nominal R{sub US}-7 h {center_dot} ft{sup 2} {center_dot} F/BTU (R{sub SI}-1.2 m{sup 2} {center_dot} K/W) fiberglass batts; (B) a layer of PEPs and one layer of the fiberglass batts; (C) four layers of the fiberglass batts; and (D) an average 4.1 in. (10.4 cm) thick layer of blown-in rock wool at an average density of 2.4 lb/ft{sup 3} (38 kg/m{sup 3}). Effects of additional sheathing were determined for Configurations B and C. With Configuration D over the ceiling, two layers of expanded polystyrene (EPS) boards, each about the same thickness as the PEPs, were installed over the trusses instead of the roof. Aluminum foils facing the attic and over the top layer of EPS were added. The top layer of EPS was then replaced by PEPs.

  18. Light Duty Combustion Research: Advanced Light-Duty Combustion...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Light Duty Combustion Research: Advanced Light-Duty Combustion Experiments Light Duty Combustion Research: Advanced Light-Duty Combustion Experiments 2009 DOE Hydrogen Program and...

  19. Exciting White Lighting

    Broader source: Energy.gov [DOE]

    Windows that emit light and are more energy efficient? Universal Display’s PHOLED technology enables windows that have transparent light-emitting diodes in them.

  20. The technical viability of alternative blowing agents in polyisocyanurate roof insulation: A cooperative industry/government project

    SciTech Connect (OSTI)

    Christian, J.E.; Courville, G.E.; Desjarlais, A.O.; Graves, R.S.; Linkous, R.L.; McElroy, D.L.; Weaver, F.J.; Wendt, R.L.; Yarbrough, D.W.

    1993-06-01T23:59:59.000Z

    This report is a summary of the cooperative industry/government program to establish the viability of alternative blowing agents to chlorofluorocarbons (CFCs). The project was initiated in 1989 following two workshops that focused on needed research on thermal insulation blown with substitutes for CFC-11 and CFC-12. The project is directed by a steering committee of representatives of the sponsors and of Oak Ridge National Laboratory (ORNL). The purpose of the project is to determine if the performance of polyisocyanurate (PIR) roof insulation foam boards blown with alternate agents differs from the performance of boards blown with CFC-1. This report describes apparent thermal conductivity (k) results obtained from field and laboratory tests from 1989 to 1992 on a set of experimental PIR laminate boardstock produced to evaluate the viability of alternative hydrochlorofluorocarbons (HCFCs) as blowing agents. All boardstock was manufactured from similar formulations that were not optimized for thermal performance. Commercial broadstock made in the future may differ in performance from this set. The PIR boards were prepared with CFC-11, HCFC-123, HCFC-141b, and 50/50 and 65/35 blends of HCFC-123/HCFC-141b.

  1. Aluminum Bronze Alloys to Improve the System Life of Basic Oxygen and Electric Arc Furnace Hoods, Roofs and Side Vents.

    SciTech Connect (OSTI)

    Lawrence C. Boyd Jr.; Dr. Vinod K. Sikka

    2006-12-29T23:59:59.000Z

    Energy Industries of Ohio was the lead organization for a consortium that examined the current situation involving the service life of electric arc and basic oxygen furnace hoods, roofs and side vents. Republic Engineered Products (REP), one of the project partners, installed a full-scale Al-Bronze “skirt” in their BOF at their Lorain OH facility, believed to be the first such installation of this alloy in this service. In 24 months of operation, the Al-Bronze skirt has processed a total of 4,563 heats, requiring only 2 shutdowns for maintenance, both related to physical damage to the skirt from operational mishaps. Yearly energy savings related to the REP facility are projected to be ~ 10 billion Btu's with significant additional environmental and productivity benefits. In recognition of the excellent results, this project was selected as the winner of the Ohio’s 2006 Governor’s Award for Excellence in Energy, the state’s award for outstanding achievements in energy efficiency.

  2. Fuel Economy and Emissions Effects of Low Tire Pressure, Open Windows, Roof Top and Hitch-Mounted Cargo, and Trailer

    SciTech Connect (OSTI)

    Thomas, John F [ORNL] [ORNL; Huff, Shean P [ORNL] [ORNL; West, Brian H [ORNL] [ORNL

    2014-01-01T23:59:59.000Z

    To quantify the fuel economy (FE) effect of some common vehicle accessories or alterations, a compact passenger sedan and a sport utility vehicle (SUV) were subjected to SAE J2263 coastdown procedures. Coastdowns were conducted with low tire pressure, all windows open, with a roof top or hitch-mounted cargo carrier, and with the SUV pulling an enclosed cargo trailer. From these coastdowns, vehicle dynamometer coefficients were developed which enabled the execution of vehicle dynamometer experiments to determine the effect of these changes on vehicle FE and emissions over standard drive cycles and at steady highway speeds. The FE penalty associated with the rooftop cargo box mounted on the compact sedan was as high as 25-27% at higher speeds, where the aerodynamic drag is most pronounced. For both vehicles, use of a hitch mounted cargo tray carrying a similar load resulted in very small FE penalties, unlike the rooftop cargo box. The results for the SUV pulling a 3500 pound enclosed cargo trailer were rather dramatic, resulting in FE penalties ranging from 30%, for the city cycle, to 50% at 80 mph, at which point significant CO generation indicated protective enrichment due to high load. Low tire pressure cases resulted in negligible to 10% FE penalty depending on the specific case and test point. Driving with all four windows open decreased FE by 4-8.5% for the compact sedan, and 1-4% for the SUV.

  3. PFP Emergency Lighting Study

    SciTech Connect (OSTI)

    BUSCH, M.S.

    2000-02-02T23:59:59.000Z

    NFPA 101, section 5-9 mandates that, where required by building classification, all designated emergency egress routes be provided with adequate emergency lighting in the event of a normal lighting outage. Emergency lighting is to be arranged so that egress routes are illuminated to an average of 1.0 footcandle with a minimum at any point of 0.1 footcandle, as measured at floor level. These levels are permitted to drop to 60% of their original value over the required 90 minute emergency lighting duration after a power outage. The Plutonium Finishing Plant (PFP) has two designations for battery powered egress lights ''Emergency Lights'' are those battery powered lights required by NFPA 101 to provide lighting along officially designated egress routes in those buildings meeting the correct occupancy requirements. Emergency Lights are maintained on a monthly basis by procedure ZSR-12N-001. ''Backup Lights'' are battery powered lights not required by NFPA, but installed in areas where additional light may be needed. The Backup Light locations were identified by PFP Safety and Engineering based on several factors. (1) General occupancy and type of work in the area. Areas occupied briefly during a shiftly surveillance do not require backup lighting while a room occupied fairly frequently or for significant lengths of time will need one or two Backup lights to provide general illumination of the egress points. (2) Complexity of the egress routes. Office spaces with a standard hallway/room configuration will not require Backup Lights while a large room with several subdivisions or irregularly placed rooms, doors, and equipment will require Backup Lights to make egress safer. (3) Reasonable balance between the safety benefits of additional lighting and the man-hours/exposure required for periodic light maintenance. In some plant areas such as building 236-Z, the additional maintenance time and risk of contamination do not warrant having Backup Lights installed in all rooms. Sufficient light for egress is provided by existing lights located in the hallways.

  4. Lighting and Daylight Harvesting

    E-Print Network [OSTI]

    Bos, J.

    2011-01-01T23:59:59.000Z

    exposing us to the latest products and technologies. Daylight Harvesting A system of controlling the direction and the quantity of light both natural and artificial within a given space. This implies: Control of fenestration in terms of size..., transmission and direction. Control of reflected light within a space. Control of electric light in terms of delivery and amount Daylight harvesting systems are typically designed to maintain a minimum recommended light level. This light level...

  5. EK101 Engineering Light Project: Evaluate Residential Lighting

    E-Print Network [OSTI]

    Bifano, Thomas

    EK101 Engineering Light Project: Evaluate Residential Lighting Compare technical and economic characteristics of three sources of residential light. Two teams of four complete the same project Engineering Light Project: Evaluate Residential Lighting Project Assignment: Evaluate current options

  6. Case Study- Steam System Improvements at Dupont Automotive Marshall Laboratory 

    E-Print Network [OSTI]

    Larkin, A.

    2002-01-01T23:59:59.000Z

    Dupont's Marshall Laboratory is an automotive paint research and development facility in Philadelphia, Pennsylvania. The campus is comprised of several buildings that are served by Trigen-Philadelphia Energy Corporation's district steam loop...

  7. Steam System Opportunity Assessment for the Pulp and Paper, Chemical...

    Broader source: Energy.gov (indexed) [DOE]

    of the U.S. Pulp and Paper Industry Energy Use Loss and Opportunities Analysis: U.S. Manufacturing & Mining U.S. Manufacturing Energy Use and Greenhouse Gas Emissions Analysis...

  8. Preliminary Results from the Industrial Steam System Market Assessment

    E-Print Network [OSTI]

    McGrath, G. P.; Wright, A. L.

    /0353, Gas Research Institute, September 1996. [3] Scoping Study Pulp and Paper Industry, EPRI, Prepared by Giese & Associates, December 1988. [4] Directory ojthe Pulp, Paper, and Allied Trades, Lockwood Post, 1996. [5] 1992 Industrial Process Heat...,000 2,400 5500 18400 38500 Mechanical 8.000 25000 6.500 17,200 14,500 42,000 Sulfite semi-chemical 17,000 35,000 4,100 6,800 21,000 41.800 Chemi-thermal mechanical 9,000 25,000 7500 16,400 16,500 41,400 Thousand Btusfton Table 4. Pulp and Paper...

  9. ProSteam- A Structured Approach to Steam System Improvement

    E-Print Network [OSTI]

    Eastwood, A.

    and of any operational constraints. It can also be used to determine the true cost of improvement projects, relating any changes in steam demand back to purchased utilities (fuel, power, and make-up water) at the site boundary. Example projects could include...

  10. Steam Basics: Use Available Data to Lower Steam System Cost

    E-Print Network [OSTI]

    Risko, J. R.

    2011-01-01T23:59:59.000Z

    of the 2011 Industrial Energy Technology Conference New Orleans, Louisiana, May 17-19, 2011 13. Is there never enough time or resource to periodically blow down strainers / drip pockets? 14. Is there a ?one size fits all? approach towards steam trap... selection; using the same model for all drip and tracer applications? 15. Does the site remove strainer screens from steam traps to prevent blockage? 16. Is at least the same amount of steam produced today as 4 years ago? 17. In the past 3 years, has...

  11. Case Study- Steam System Improvements at Dupont Automotive Marshall Laboratory

    E-Print Network [OSTI]

    Larkin, A.

    globe valve to enable manual throttling of the steam, a strainer, a steam trap and a pressure relief safety valve, in addition to the pressure reducing valve (pRY). Properly selected PRVs need to have seats replaced about every five years...

  12. Steam Power Partnership: Improving Steam System Efficiency Through Marketplace Partnerships 

    E-Print Network [OSTI]

    Jones, T.

    1997-01-01T23:59:59.000Z

    been great advances in boiler control technology as older pneumatic and analog electronic control systems have given way to digital, computer-based distributed control systems. These systems are more reliable and can extend boiler life. Modem... Several software tools are now available for individual steam technologies, such as steam traps, insulation, and boiler controls. The Partnership should investigate linking these software tools together and incorporating other steam "modules" (i...

  13. Design manual for high temperature hot water and steam systems

    SciTech Connect (OSTI)

    Cofield, R.E. Jr.

    1984-01-01T23:59:59.000Z

    The author presents aspects of high temperature hot water and steam generating systems. It covers all the calculations that must be made for sizing and then selecting the equipment that will make up an energy system. The author provides essential information on loan analysis, types of fuel, storage requirements, handling facilities, waste disposal, HVAC needs, and back-up systems. Also included are the calculations needed for determining the size of compressors, air pollution devices, fans, filters, and other supplementary equipment.

  14. Steam System Balancing and Tuning for Multifamily Residential...

    Energy Savers [EERE]

    for Advanced Residential Retrofit www.gastechnology.org Building Component: Steam heating distribution system and controls Application: Retrofit; Multifamily Year Tested:...

  15. Steam System Management Program Yields Fuel Savings for Refinery

    E-Print Network [OSTI]

    Gaines, L. D.; Hagan, K. J.

    1983-01-01T23:59:59.000Z

    The Phillips refinery at Borger, Texas, determined the need to develop a utility monitoring system. Shortly after this commitment was made, the refinery was introduced to a flowsheet modeling program that could be used to model and optimize steam...

  16. "Greening" Industrial Steam Generation via On-demand Steam Systems 

    E-Print Network [OSTI]

    Smith, J. P.

    2010-01-01T23:59:59.000Z

    Both recent economic and environmental conditions in the U.S. have converged to bring about unprecedented attention to energy efficiency and sustainability in the country's industrial sector. Historically, energy costs in ...

  17. Economics of high performance steam systems (HPSS) cogeneration: A handbook

    SciTech Connect (OSTI)

    Not Available

    1992-06-01T23:59:59.000Z

    This guidebook aims to farther industry's knowledge of HPSS and their potential benefits. It is also intended to provide industrial end-users with a basis for judging the merits of HPSS under various site-specific conditions by outlining the economics of HPSS and conventional cogeneration systems compared to boilers under representative sets of industrial process conditions. Electric utility companies have experimented with steam pressures in the range of 5,000 psig and temperatures up to 1,200[degrees]F, but generally have remained with more conservative throttle conditions of 2,400 psig, 1,000[degrees]F to improve reliability. Most industrial applications have used steam throttle conditions below 900 psig and 900[degrees]F. Yet thermodynamic analysis shows that in a steam turbine generator, the amount of electricity generated per pound of steam increases as the inlet steam temperature and pressure are increased. Furthermore, the incremental electricity that is generated by raising the steam temperature and pressure is produced in a highly efficient manner. Efforts in this direction explain why, recently, some industrial projects have been built with steam turbine inlet turbine conditions of 1,500 psig and above. The HPSS concept goes one step further: It is based on a high-temperature steam generator capable of producing 1,500[degrees]F superheated steam and a high-speed steam turbine-generator. By utilizing the HPSS system as a topping'' system, high-pressure steam can be expanded from 1,500[degrees]F to the traditional temperatures used by industry.

  18. Economics of high performance steam systems (HPSS) cogeneration: A handbook

    SciTech Connect (OSTI)

    Not Available

    1992-06-01T23:59:59.000Z

    This guidebook aims to farther industry`s knowledge of HPSS and their potential benefits. It is also intended to provide industrial end-users with a basis for judging the merits of HPSS under various site-specific conditions by outlining the economics of HPSS and conventional cogeneration systems compared to boilers under representative sets of industrial process conditions. Electric utility companies have experimented with steam pressures in the range of 5,000 psig and temperatures up to 1,200{degrees}F, but generally have remained with more conservative throttle conditions of 2,400 psig, 1,000{degrees}F to improve reliability. Most industrial applications have used steam throttle conditions below 900 psig and 900{degrees}F. Yet thermodynamic analysis shows that in a steam turbine generator, the amount of electricity generated per pound of steam increases as the inlet steam temperature and pressure are increased. Furthermore, the incremental electricity that is generated by raising the steam temperature and pressure is produced in a highly efficient manner. Efforts in this direction explain why, recently, some industrial projects have been built with steam turbine inlet turbine conditions of 1,500 psig and above. The HPSS concept goes one step further: It is based on a high-temperature steam generator capable of producing 1,500{degrees}F superheated steam and a high-speed steam turbine-generator. By utilizing the HPSS system as a ``topping`` system, high-pressure steam can be expanded from 1,500{degrees}F to the traditional temperatures used by industry.

  19. "Greening" Industrial Steam Generation via On-demand Steam Systems

    E-Print Network [OSTI]

    Smith, J. P.

    2010-01-01T23:59:59.000Z

    impact have not kept pace with other industrialized nations. The U.S. is confronted with looming tipping points with respect to energy supply and GHG emissions that represent very tangible constraints on future economic growth and quality of life. A...

  20. Best Management Practice #8: Boiler and Steam Systems

    Broader source: Energy.gov [DOE]

    Boilers and steam generators are commonly used in large heating systems, institutional kitchens, or in facilities where large amounts of process steam are used. This equipment consumes varying amounts of water depending on system size, the amount of steam used, and the amount of condensate returned.

  1. Improving Steam System Performance: A Sourcebook for Industry, Second

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742Energy ChinaofSchaefer To:DepartmentDepartment of Energy ImplementingBasis

  2. Save Energy Now in Your Steam Systems | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn'tOrigin ofEnergy atLLC - FE DKT. 10-160-LNG -EnergyProcess Heating Systems Process

  3. Improving Steam System Performance: A Sourcebook for Industry, Second

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed off Energy.gov.Energy02.pdf7 OPAM Flash2011-37EnergySubmitRoad |WaterEdition | Department of

  4. List of Steam-system upgrades Incentives | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand Jump to: navigation, searchOf KilaueaInformation Other Alternative FuelEnergysource History View

  5. Deaerators in Industrial Steam Systems | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 1112011AT&T,Office of Policy, OAPMMilestone |Procurement of KWrittenAmerica'sDeaerators in

  6. Save Energy Now in Your Steam Systems | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreakingMay 2015 <Department ofDepartment ofEnergyFebruaryProcess HeatingSteam

  7. Industrial Steam System Heat-Transfer Solutions | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreaking of BlytheDepartment of EnergyTreatment andJuneJobs Thomas

  8. Industrial Steam System Process-Control Schemes | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreaking of BlytheDepartment of EnergyTreatment andJuneJobs ThomasProcess-Control

  9. Deaerators in Industrial Steam Systems | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny:Revised Finding of No53197 This workDayton: ENERGY

  10. Steam System Opportunity Assessment for the Pulp and Paper, Chemical

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreakingMayDepartment of Staffing Model5ThomasEnergyReceives Energy Assessment

  11. Steam System Opportunity Assessment for the Pulp and Paper, Chemical

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn'tOriginEducationVideo »UsageSecretaryVideosSpringoutAPBF-DEC NOxBestPractices Steam

  12. Industrial Steam System Heat-Transfer Solutions | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't YourTransport(Fact Sheet),EnergyImprovementINDIAN COUNTRYBarriers toHeat Pumps

  13. In-situ and thin-specimen aging of experimental polyisocyanurate roof insulation foamed with alternative blowing agents

    SciTech Connect (OSTI)

    Christian, J.E.; Courville, G.E.; Graves, R.S.; Linkous, R.L.; McElroy, D.L.; Weaver, F.J.; Yarbrough, D.W.

    1991-01-01T23:59:59.000Z

    This paper reports apparent thermal conductivity (k) values from field and laboratory aging tests on a set of industry-produced, experimental polyisocyanurate (PIR) laminated boardstock foamed with hydrochlorofluorocarbons (HCFCs) as alternatives to chlorofluorocarbon (CFC). The PIR boards were blown with five gases: CFC-11, HCFC-123, HCFC-14lb, and 50/50 and 65/35 blends of HCFC-123/HCFC-14lb. The k-values were determined from 0 to 50{degree}C (30 to 120{degree}F) using techniques that meet ASTM C 114 (Thin Heater Apparatus) and ASTM C 518 (Heat Flow Meter Apparatus). Results on laminate boards with facers provide an independent laboratory check on the increase in k observed for field exposure in the ORNL Roof Thermal Research Apparatus (RTRA). The observed laboratory increase in k was between 8% and 11% for a 240 day field exposure in the RTRA. A thin-specimen aging procedure established the long-term thermal resistance of gas-filled foams. Thin specimens were planed from the industry-produced boardstock foams and aged at 24 and 65{degree}C (75{degree}F and 150{degree}F) for up to 300 days. An exponential dependency of k with the quantity (diffusion coefficient X time){sup {1/2}}/ thickness, provide effective diffusion coefficients for air components into the foams and blowing agent out of the foams. The foams blown with alternative blowing agents exhibited k-values 3 to 16% (average 9.4%) above CFC-11 foams under similar conditions. Field exposures were conducted on specimens under single ply EPDM membranes in the RTRA for over 400 days. Hourly averages of panel temperature and heat flux were analyzed to obtain K as a function of mean temperature on a week by week basis. The relative performance of test specimens of HCFC-14B under a black and under a white membrane is reported. 29 refs., 10 figs., 10 tabs.

  14. Deficiencies of Lighting Codes and Ordinances in Controlling Light Pollution from Parking Lot Lighting Installations

    E-Print Network [OSTI]

    Royal, Emily

    2012-05-31T23:59:59.000Z

    The purpose of this research was to identify the main causes of light pollution from parking lot electric lighting installations and highlight the deficiencies of lighting ordinances in preventing light pollution. Using an industry-accepted lighting...

  15. OpenGL Lighting 13. OpenGL Lighting

    E-Print Network [OSTI]

    McDowell, Perry

    OpenGL Lighting 13. OpenGL Lighting · Overview of Lighting in OpenGL In order for lighting to have an effect in OpenGL, two things are required: A light An object to be lit Lights can be set to any color determine how they reflect the light which hits them. The color(s) of an object is determined

  16. Adaptive Street Lighting Controls

    Broader source: Energy.gov [DOE]

    This two-part DOE Municipal Solid-State Street Lighting Consortium webinar focused on LED street lighting equipped with adaptive control components. In Part I, presenters Amy Olay of the City of...

  17. Sandia National Laboratories: Lighting

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Lighting Solid-State Lighting Science EFRC On November 11, 2010, in Welcome History of Incandescence History of LEDs Grand Challenges Our EFRC SSLS-EFRC Contacts News Publications...

  18. Light emitting device comprising phosphorescent materials for white light generation

    DOE Patents [OSTI]

    Thompson, Mark E.; Dapkus, P. Daniel

    2014-07-22T23:59:59.000Z

    The present invention relates to phosphors for energy downconversion of high energy light to generate a broadband light spectrum, which emit light of different emission wavelengths.

  19. Advanced Demand Responsive Lighting

    E-Print Network [OSTI]

    Advanced Demand Responsive Lighting Host: Francis Rubinstein Demand Response Research Center demand responsive lighting systems ­ Importance of dimming ­ New wireless controls technologies · Advanced Demand Responsive Lighting (commenced March 2007) #12;Objectives · Provide up-to-date information

  20. Light Rail Transit Strengthening

    E-Print Network [OSTI]

    Minnesota, University of

    Light Rail Transit Improving mobility Easing congestion Strengthening our communities Central Corridor Communicating to the Public During Major Construction May 25, 2011 #12;2 Light Rail Transit;Light Rail Transit Central Corridor Route and Stations 3 · 18 new stations · 9.8 miles of new double

  1. Light extraction from organic light-emitting diodes for lighting applications by sand-blasting

    E-Print Network [OSTI]

    Light extraction from organic light-emitting diodes for lighting applications by sand@ust.hk Abstract: Light extraction from organic light-emitting diodes (OLEDs) by scattering the light is one of the effective methods for large-area lighting applications. In this paper, we present a very simple and cost

  2. Photonic crystal light source

    DOE Patents [OSTI]

    Fleming, James G. (Albuquerque, NM); Lin, Shawn-Yu (Albuquerque, NM); Bur, James A. (Corrales, NM)

    2004-07-27T23:59:59.000Z

    A light source is provided by a photonic crystal having an enhanced photonic density-of-states over a band of frequencies and wherein at least one of the dielectric materials of the photonic crystal has a complex dielectric constant, thereby producing enhanced light emission at the band of frequencies when the photonic crystal is heated. The dielectric material can be a metal, such as tungsten. The spectral properties of the light source can be easily tuned by modification of the photonic crystal structure and materials. The photonic crystal light source can be heated electrically or other heating means. The light source can further include additional photonic crystals that exhibit enhanced light emission at a different band of frequencies to provide for color mixing. The photonic crystal light source may have applications in optical telecommunications, information displays, energy conversion, sensors, and other optical applications.

  3. Foundations and Light Compass Foundations and Light Compass

    E-Print Network [OSTI]

    Wong, Jennifer L.

    Foundations and Light Compass Case Study Foundations and Light Compass Case Study Jennifer L. WongQuantitative Sensor--centric Designcentric Design Light CompassLight Compass ­­ Models and Abstractions Contaminant Transport Marine Microorganisms Ecosystems, Biocomplexity What is a Light Compass?What is a Light

  4. Lighting and Surfaces 11.1 Introduction to Lighting

    E-Print Network [OSTI]

    Boyd, John P.

    Chapter 11 Lighting and Surfaces 11.1 Introduction to Lighting Three-dimensional surfaces can react to light, and how computer graphics simulates this. There are three species of light (or "illumination models"): 1. Intrinsic (self-emitting) 2. Ambient light (sometimes called "diffuse light") 3

  5. Arnold Schwarzenegger LIGHTING RESEARCH PROGRAM

    E-Print Network [OSTI]

    Project Summaries ELEMENT 2: ADVANCE LIGHTING TECHNOLOGIES PROJECT 2.1 LIGHT EMITTING DIODE (LED light emitting diodes (LED) technology for general lighting applications by developing a task lamp

  6. Energy 101: Lighting Choices | Department of Energy

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville Power AdministrationField Campaign:INEAWaterCool Roofs Energy 101: Cool Roofs

  7. Percolating under one roof

    E-Print Network [OSTI]

    Miller, Joel C

    2015-01-01T23:59:59.000Z

    Many different concepts of percolation exist for networks. We show that bond percolation, site percolation, $k$-core percolation, and bootstrap percolation are all special cases of the Watts Threshold model. We show that the "heterogeneous $k$-core" and a corresponding heterogeneous bootstrap model are equivalent to one another and the Watts Threshold Model. A more recent model of a "Generalized Epidemic Process" is also shown to be a special case. Finally, we show that a natural generalization of the Watts Threshold Model is a special case of the Watts Threshold Model, and thus it is equivalent to the Watts Threshold Model as well.

  8. Photovoltaic roof heat flux

    E-Print Network [OSTI]

    Samady, Mezhgan Frishta

    2011-01-01T23:59:59.000Z

    transient the heat transfer model. T h i s required the roofto develop and calibrate heat transfer models to be able toE S station, the heat transfer models described i n sections

  9. Photovoltaic roof heat flux

    E-Print Network [OSTI]

    Samady, Mezhgan Frishta

    2011-01-01T23:59:59.000Z

    d b y t h e a n g l e d solar panel F i g u r e 62: C a l cK l e i s s l , C h a i r Solar panels were mounted w i t hthe optimal angles for solar panels [9], i n this study both

  10. Roofing Moisture Tolerance

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's PossibleRadiation Protection TechnicalResonantNovember 15 toAdvancesRockSodiumWIPP UPDATE:

  11. High efficiency incandescent lighting

    DOE Patents [OSTI]

    Bermel, Peter; Ilic, Ognjen; Chan, Walker R.; Musabeyoglu, Ahmet; Cukierman, Aviv Ruben; Harradon, Michael Robert; Celanovic, Ivan; Soljacic, Marin

    2014-09-02T23:59:59.000Z

    Incandescent lighting structure. The structure includes a thermal emitter that can, but does not have to, include a first photonic crystal on its surface to tailor thermal emission coupled to, in a high-view-factor geometry, a second photonic filter selected to reflect infrared radiation back to the emitter while passing visible light. This structure is highly efficient as compared to standard incandescent light bulbs.

  12. National Synchrotron Light Source

    ScienceCinema (OSTI)

    BNL

    2009-09-01T23:59:59.000Z

    A tour of Brookhaven's National Synchrotron Light Source (NSLS), hosted by Associate Laboratory Director for Light Sources, Stephen Dierker. The NSLS is one of the world's most widely used scientific research facilities, hosting more than 2,500 guest researchers each year. The NSLS provides intense beams of infrared, ultraviolet, and x-ray light for basic and applied research in physics, chemistry, medicine, geophysics, environmental, and materials sciences.

  13. LED Lighting Retrofit

    E-Print Network [OSTI]

    Shaw-Meadow, N.

    2011-01-01T23:59:59.000Z

    ? Municipal Street Lighting Consortium ? American Public Power Association (APPA) ? Demonstration in Energy Efficiency Development (DEED) ? Source of funding and database of completed LED roadway projects 6 Rules of the Road ESL-KT-11-11-57 CATEE 2011..., 2011 ? 9 Solar-Assisted LED Case Study LaQuinta Hotel, Cedar Park, Texas ? Utilizes 18 - ActiveLED Solar-Assisted Parking Lot Lights ? Utilizes ?power management? to extend battery life while handling light output ? Reduces load which reduces PV...

  14. Edmund G. Brown Jr. LIGHTING CALIFORNIA'S FUTURE

    E-Print Network [OSTI]

    Edmund G. Brown Jr. Governor LIGHTING CALIFORNIA'S FUTURE: SMART LIGHT-EMITTING DIODE LIGHTING's Future: Smart LightEmitting Diode Lighting in Residential Fans. California Energy Commission, PIER

  15. Comparing Light Bulbs

    Broader source: Energy.gov [DOE]

    In this exercise, students will use a light to demonstrate the difference between being energy-efficient and energy-wasteful, and learn what energy efficiency means.

  16. Total Light Management

    Broader source: Energy.gov [DOE]

    Presentation covers total light management, and is given at the Spring 2010 Federal Utility Partnership Working Group (FUPWG) meeting in Providence, Rhode Island.

  17. Lighting Technology Panel

    Broader source: Energy.gov [DOE]

    Presentation covers the Lighting Technology Panel for the Federal Utility Partnership Working Group (FUPWG) meeting, held on November 18-19, 2009. 

  18. Hybrid Solar Lighting

    SciTech Connect (OSTI)

    Maxey, L Curt [ORNL

    2008-01-01T23:59:59.000Z

    Hybrid solar lighting systems focus highly concentrated sunlight into a fiber optic bundle to provide sunlight in rooms without windows or conventional skylights.

  19. Solid-State Lighting

    Broader source: Energy.gov (indexed) [DOE]

    into the market. On the market side, DOE works closely with drivers, heat sinks, and optics. LEDs must be carefully energy efficiency program partners, lighting professionals,...

  20. Building America Case Study: Cost Analysis of Roof-Only Air Sealing and Insulation Strategies on 1-1/2 Story Homes in Cold Climates, Minneapolis, MN (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2014-12-01T23:59:59.000Z

    The External Thermal and Moisture Management System (ETMMS), typically seen in deep energy retrofits, is a valuable approach for the roof-only portions of existing homes, particularly the 1 1/2-story home. It is effective in reducing energy loss through the building envelope, improving building durability, reducing ice dams, and providing opportunities to improve occupant comfort and health.

  1. Reducing home lighting expenses

    SciTech Connect (OSTI)

    Aimone, M.A.

    1981-02-01T23:59:59.000Z

    Ways to reduce lighting expenses are summarized. These include: turning off lights when not in use; keeping fixtures and lamps clean; replacing lamps with more efficient types; using three-way bulbs; use of daylighting; buying fewer lamps and reducing lamp wattage; consider repainting rooms; replacing recessed fixtures with tracklighting; and using efficient lamps for outdoor use. (MCW)

  2. Explosively pumped laser light

    DOE Patents [OSTI]

    Piltch, Martin S. (Los Alamos, NM); Michelotti, Roy A. (Los Alamos, NM)

    1991-01-01T23:59:59.000Z

    A single shot laser pumped by detonation of an explosive in a shell casing. The shock wave from detonation of the explosive causes a rare gas to luminesce. The high intensity light from the gas enters a lasing medium, which thereafter outputs a pulse of laser light to disable optical sensors and personnel.

  3. Light intensity compressor

    DOE Patents [OSTI]

    Rushford, Michael C. (Livermore, CA)

    1990-01-01T23:59:59.000Z

    In a system for recording images having vastly differing light intensities over the face of the image, a light intensity compressor is provided that utilizes the properties of twisted nematic liquid crystals to compress the image intensity. A photoconductor or photodiode material that is responsive to the wavelength of radiation being recorded is placed adjacent a layer of twisted nematic liquid crystal material. An electric potential applied to a pair of electrodes that are disposed outside of the liquid crystal/photoconductor arrangement to provide an electric field in the vicinity of the liquid crystal material. The electrodes are substantially transparent to the form of radiation being recorded. A pair of crossed polarizers are provided on opposite sides of the liquid crystal. The front polarizer linearly polarizes the light, while the back polarizer cooperates with the front polarizer and the liquid crystal material to compress the intensity of a viewed scene. Light incident upon the intensity compressor activates the photoconductor in proportion to the intensity of the light, thereby varying the field applied to the liquid crystal. The increased field causes the liquid crystal to have less of a twisting effect on the incident linearly polarized light, which will cause an increased percentage of the light to be absorbed by the back polarizer. The intensity of an image may be compressed by forming an image on the light intensity compressor.

  4. Lighting affects appearance LightSource emits photons

    E-Print Network [OSTI]

    Jacobs, David

    1 Lighting affects appearance #12;2 LightSource emits photons Photons travel in a straight line). And then some reach the eye/camera. #12;3 Reflectance Model how objects reflect light. Model light sources Algorithms for computing Shading: computing intensities within polygons Determine what light strikes what

  5. VIRTUAL LIGHT: DIGITALLY-GENERATED LIGHTING FOR VIDEO CONFERENCING APPLICATIONS

    E-Print Network [OSTI]

    Fisher, Kathleen

    VIRTUAL LIGHT: DIGITALLY-GENERATED LIGHTING FOR VIDEO CONFERENCING APPLICATIONS Andrea Basso method to improve the lighting conditions of a real scene or video sequence. In particular we concentrate on modifying real light sources intensities and inserting virtual lights into a real scene viewed from a fixed

  6. Lakeview Light and Power- Commercial Lighting Rebate Program

    Broader source: Energy.gov [DOE]

    Lakeview Light and Power offers a commercial lighting rebate program. Rebates apply to the installation of energy efficient lighting retrofits in non-residential buildings. The rebate program is...

  7. Green Light Pulse Oximeter

    DOE Patents [OSTI]

    Scharf, John Edward (Oldsmar, FL)

    1998-11-03T23:59:59.000Z

    A reflectance pulse oximeter that determines oxygen saturation of hemoglobin using two sources of electromagnetic radiation in the green optical region, which provides the maximum reflectance pulsation spectrum. The use of green light allows placement of an oximetry probe at central body sites (e.g., wrist, thigh, abdomen, forehead, scalp, and back). Preferably, the two green light sources alternately emit light at 560 nm and 577 nm, respectively, which gives the biggest difference in hemoglobin extinction coefficients between deoxyhemoglobin, RHb, and oxyhemoglobin, HbO.sub.2.

  8. White light velocity interferometer

    DOE Patents [OSTI]

    Erskine, D.J.

    1999-06-08T23:59:59.000Z

    The invention is a technique that allows the use of broadband and incoherent illumination. Although denoted white light velocimetry, this principle can be applied to any wave phenomenon. For the first time, powerful, compact or inexpensive sources can be used for remote target velocimetry. These include flash and arc lamps, light from detonations, pulsed lasers, chirped frequency lasers, and lasers operating simultaneously in several wavelengths. The technique is demonstrated with white light from an incandescent source to measure a target moving at 16 m/s. 41 figs.

  9. Sandia Energy - (Lighting and) Solid-State Lighting: Science...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    on the third and upcoming revolution (illumination). Topics cover the basics of light-emitting diode (LED) operation; a 200-year history of lighting technology; the importance of...

  10. Sandia National Laboratories: (Lighting and) Solid-State Lighting...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    on the third and upcoming revolution (illumination). Topics cover the basics of light-emitting diode (LED) operation; a 200-year history of lighting technology; the importance of...

  11. Columbia Water and Light- HVAC and Lighting Efficiency Rebates

    Broader source: Energy.gov [DOE]

    Columbia Water and Light (CWL) offers rebates to its commercial and industrial customers for the purchase of high efficiency HVAC installations and efficient lighting. Incentives for certain...

  12. Reading Municipal Light Department- Business Lighting Rebate Program

    Broader source: Energy.gov [DOE]

    Reading Municipal Light Department (RMLD) offers incentives for non-residential customers to install energy efficient lights and sensors in existing facilities. In addition to rebates for the...

  13. Peninsula Light Company- Commercial Efficient Lighting Rebate Program

    Broader source: Energy.gov [DOE]

    Peninsula Light Company (PLC) offers a rebate program for commercial customers who wish to upgrade to energy efficient lighting. Participating customers must be served by PLC commercial service....

  14. Light Duty Combustion Research: Advanced Light-Duty Combustion...

    Broader source: Energy.gov (indexed) [DOE]

    duty Diesel Combustion Research Advanced Light-Duty Combustion Experiments Paul Miles Sandia National Laboratories Light-Duty Combustion Modeling Rolf Reitz University of Wisconsin...

  15. Efficient Light Sources Today

    E-Print Network [OSTI]

    Hart, A. L.

    1982-01-01T23:59:59.000Z

    This paper reviews new lamp and lighting technology in terms of application and economic impact. Included are the latest advances in High Intensity Discharge systems, energy saving fluorescent lamps and ballasts, and the new state of the art high...

  16. Natural lighting and skylights

    E-Print Network [OSTI]

    Evans, Benjamin Hampton

    1961-01-01T23:59:59.000Z

    outlined herein, the feasibility of using scale models for studying skylights is also an established fact. The method of analysis by models can be a valuable tool to any designer who is concerned about day-lighting....

  17. National Synchrotron Light Source

    ScienceCinema (OSTI)

    None

    2010-01-08T23:59:59.000Z

    A tour of Brookhaven's National Synchrotron Light Source (NSLS). The NSLS is one of the world's most widely used scientific research facilities, hosting more than 2,500 guest researchers each year. The NSLS provides intense beams of infrared, ultraviole

  18. Light Vector Mesons

    E-Print Network [OSTI]

    Alexander Milov

    2008-12-21T23:59:59.000Z

    This article reviews the current status of experimental results obtained in the measurement of light vector mesons produced in proton-proton and heavy ion collisions at different energies. The review is focused on two phenomena related to the light vector mesons; the modification of the spectral shape in search of Chiral symmetry restoration and suppression of the meson production in heavy ion collisions. The experimental results show that the spectral shape of light vector mesons are modified compared to the parameters measured in vacuum. The nature and the magnitude of the modification depends on the energy density of the media in which they are produced. The suppression patterns of light vector mesons are different from the measurements of other mesons and baryons. The mechanisms responsible for the suppression of the mesons are not yet understood. Systematic comparison of existing experimental results points to the missing data which may help to resolve the problem.

  19. Light and Plants Plants use light to photosynthesize. Name two places that light can come from

    E-Print Network [OSTI]

    Koptur, Suzanne

    Light and Plants Plants use light to photosynthesize. Name two places that light can come from: 1 (CO2, a gas) from the air and turn it into SUGARS (food). This process is powered by energy from light plants) for energy. Photosynthetically Active Radiation (PAR) is a combination of red light and blue

  20. Light and Energy -Daylight measurements

    E-Print Network [OSTI]

    Light and Energy - Daylight measurements #12;Light and Energy - Daylight measurements Authors: Jens;3 Title Light and Energy Subtitle Daylight measurements Authors Jens Christoffersen, Ásta Logadóttir ........................................................................................................ 5 Daylight quantity