Powered by Deep Web Technologies
Note: This page contains sample records for the topic "large commercial critical" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Duct systems in large commercial buildings: physical characterization...  

NLE Websites -- All DOE Office Websites (Extended Search)

Duct systems in large commercial buildings: physical characterization, air leakage and heat conduction gains Title Duct systems in large commercial buildings: physical...

2

Duct Systems in Large Commercial Buildings: Physical  

NLE Websites -- All DOE Office Websites (Extended Search)

Duct Systems in Large Commercial Buildings: Physical Characterization, Air Leakage, and Heat Conduction Gains William 1. Fisk, Woody Delp, Rick Diamond, Darryl Dickerhoff, Ronnen Levinson, Mark Modera, Matty Nematollahi, Duo Wang Environmental Energy Technologies Division Indoor Environment Department Lawrence Berkeley National Laboratory Berkeley CA 94720 March 30, 1999 This work was supported by the Assistant Secretary for Energy Efficiency and Renewable Energy, Office of Building Technology and Community Systems, of the US Department of Energy under Contract No. DE-AC03-76SF00098 and by the California Institute For Energy Efficiency. LBNL-42339

3

Evaluation of Retrocommissioning Persistence in Large Commercial...  

NLE Websites -- All DOE Office Websites (Extended Search)

Bldg. 90 Seminar HostPoint of Contact: Naoya Motegi Commercial Building Retro-commissioning activity has increased in recent years. Retro-commissioning is a process of...

4

National Grid (Electric) - Large Commercial Energy Efficiency Incentive  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

National Grid (Electric) - Large Commercial Energy Efficiency National Grid (Electric) - Large Commercial Energy Efficiency Incentive Programs National Grid (Electric) - Large Commercial Energy Efficiency Incentive Programs < Back Eligibility Commercial Industrial Institutional Local Government Multi-Family Residential Retail Supplier Schools State Government Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Other Construction Heat Pumps Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Custom Incentives: 50% of engineering studies and total costs until project reaches a 1.5 year simple payback. Program Info State Rhode Island Program Type Utility Rebate Program Rebate Amount Schools and New Buildings Custom Incentives: 75% of additional cost for efficiency upgrades AC/Heat Pumps: $30 - $125/ton

5

Western Riverside Council of Governments - Large Commercial PACE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Large Commercial PACE Large Commercial PACE (California) Western Riverside Council of Governments - Large Commercial PACE (California) < Back Eligibility Commercial Savings Category Other Alternative Fuel Vehicles Hydrogen & Fuel Cells Solar Buying & Making Electricity Program Info State California Program Type PACE Financing Provider Structured Finance Associates Structured Finance, on behalf of the Western Riverside Council of Governments (WRCOG), is providing Property Assessed Clean Energy (PACE) loans to eligible large commercial businesses in participating jurisdictions. PACE programs allow property owners to finance energy projects, and to repay the financing through special assessments on their property tax bill. Solar installations of at least 125 kilowatts, fuel cells, and a variety of

6

Idaho Power - Large Commercial Custom Efficiency Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Large Commercial Custom Efficiency Program Large Commercial Custom Efficiency Program Idaho Power - Large Commercial Custom Efficiency Program < Back Eligibility Agricultural Commercial Industrial Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Manufacturing Other Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Commercial and Industrial: 70% of project cost Custom Incentive for Existing Irrigation System Replacement: up to 75% of the total project cost Custom Incentive for a New Irrigation System: up to 10% of the total project cost Program Info Funding Source Conservation Program Funding Charge State Idaho Program Type Utility Rebate Program Rebate Amount Commercial and Industrial: $0.12/kWh saved Agricultural Irrigation Efficiency: $0.25/annual kWh saved or $450/kW

7

Web-based energy information systems for large commercial buildings  

E-Print Network (OSTI)

and benchmark energy use among a portfolio of buildings bybenchmark Motegi et al: Web-based Energy Information Systems For Large Commercial Buildings

Motegi, Naoya; Piette, Mary Ann

2003-01-01T23:59:59.000Z

8

Oncor Electric Delivery - Large Commercial and Industrial Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Oncor Electric Delivery - Large Commercial and Industrial Rebate Oncor Electric Delivery - Large Commercial and Industrial Rebate Program Oncor Electric Delivery - Large Commercial and Industrial Rebate Program < Back Eligibility Commercial Construction Industrial Installer/Contractor Institutional Local Government Schools State Government Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Manufacturing Other Heat Pumps Appliances & Electronics Commercial Lighting Lighting Home Weatherization Insulation Design & Remodeling Windows, Doors, & Skylights Solar Buying & Making Electricity Water Heating Wind Maximum Rebate General: 20% of the incentive budget in a given budget year Contact Oncor for additional details Program Info State Texas Program Type Utility Rebate Program Rebate Amount DX Air Conditioning: $285.30/kW; $0.09/kWh

9

Gas cooling for large commercial buildings  

SciTech Connect

Energy costs typically account for 10% to 20% of the operating costs for commercial buildings. These costs have continued to rise over the past several years notwithstanding the implementation of energy conservation programs. Increasing electric demand charges have been a major cause of the problem, and as capital-intensive nuclear and coal plants under construction are rolled into the rate base, these demand penalties are likely to become more severe. Electric cooling is the major contributor to seasonal and daily electric peaks. The use of natural gas for cooling can provide relief from high peak period electric prices either directly through absorption systems and engine-driven chillers or indirectly via cogeneration and recovered heat-driven absorption cooling. Although a window of opportunity exists for gas cooling in some parts of the country today, technological advancement and cost reduction are required in order for gas cooling to realize widespread applicability. The Gas Research Institute has implemented a comprehensive development program in cooperation with industry to evolve engine-driven chiller systems in the 100-ton and larger size range with gas coefficients of performance of 2.4, first-cost premiums of less than $100/ton, and service intervals of 4000 hours. Maintenance records of several engine-driven systems installed in the early 1970's were studied. System reliability was found to be in-line with HVAC market requirements.

Davidson, K.; Brattin, H.D.

1986-01-01T23:59:59.000Z

10

Web-based Energy Information Systems for Large Commercial Buildings  

NLE Websites -- All DOE Office Websites (Extended Search)

Web-based Energy Information Systems for Large Commercial Buildings Speaker(s): Naoya Motegi Date: May 2, 2002 - 12:00pm Location: Bldg. 90 Energy Information Systems (EIS), which...

11

Demand Shifting With Thermal Mass in Large Commercial Buildings...  

NLE Websites -- All DOE Office Websites (Extended Search)

Demand Shifting With Thermal Mass in Large Commercial Buildings: Case Studies and Tools Speaker(s): Peng Xu Date: March 9, 2007 - 12:00pm Location: 90-3122 The idea of pre-cooling...

12

Plutonium Finishing Plant (PFP) Criticality Alarm System Commercial Grade Item (CGI) Critical Characteristics  

SciTech Connect

This document specifies the critical characteristics for Commercial Grade Items (CGI) procured for PFP's criticality alarm system as required by HNF-PRO-268 and HNF-PRO-1819. These are the minimum specifications that the equipment must meet in order to properly perform its safety function. There may be several manufacturers or models that meet the critical characteristics for any one item. PFP's Criticality Alarm System includes the nine criticality alarm system panels and their associated hardware. This includes all parts up to the first breaker in the electrical distribution system. Specific system boundaries and justifications are contained in HNF-SD-CP-SDD-003, ''Definition and Means of Maintaining the Criticality Detectors and Alarms Portion of the PFP Safety Envelope.'' The procurement requirements associated with the system necessitates procurement of some system equipment as Commercial Grade Items in accordance with HNF-PRO-268, ''Control of Purchased Items and Services.''

WHITE, W.F.

1999-09-16T23:59:59.000Z

13

Duct thermal performance models for large commercial buildings  

SciTech Connect

Despite the potential for significant energy savings by reducing duct leakage or other thermal losses from duct systems in large commercial buildings, California Title 24 has no provisions to credit energy-efficient duct systems in these buildings. A substantial reason is the lack of readily available simulation tools to demonstrate the energy-saving benefits associated with efficient duct systems in large commercial buildings. The overall goal of the Efficient Distribution Systems (EDS) project within the PIER High Performance Commercial Building Systems Program is to bridge the gaps in current duct thermal performance modeling capabilities, and to expand our understanding of duct thermal performance in California large commercial buildings. As steps toward this goal, our strategy in the EDS project involves two parts: (1) developing a whole-building energy simulation approach for analyzing duct thermal performance in large commercial buildings, and (2) using the tool to identify the energy impacts of duct leakage in California large commercial buildings, in support of future recommendations to address duct performance in the Title 24 Energy Efficiency Standards for Nonresidential Buildings. The specific technical objectives for the EDS project were to: (1) Identify a near-term whole-building energy simulation approach that can be used in the impacts analysis task of this project (see Objective 3), with little or no modification. A secondary objective is to recommend how to proceed with long-term development of an improved compliance tool for Title 24 that addresses duct thermal performance. (2) Develop an Alternative Calculation Method (ACM) change proposal to include a new metric for thermal distribution system efficiency in the reporting requirements for the 2005 Title 24 Standards. The metric will facilitate future comparisons of different system types using a common ''yardstick''. (3) Using the selected near-term simulation approach, assess the impacts of duct system improvements in California large commercial buildings, over a range of building vintages and climates. This assessment will provide a solid foundation for future efforts that address the energy efficiency of large commercial duct systems in Title 24. This report describes our work to address Objective 1, which includes a review of past modeling efforts related to duct thermal performance, and recommends near- and long-term modeling approaches for analyzing duct thermal performance in large commercial buildings.

Wray, Craig P.

2003-10-01T23:59:59.000Z

14

Sealing Ducts in Large Commercial Buildings with Aerosolized Sealant Particles  

NLE Websites -- All DOE Office Websites (Extended Search)

2414 2414 1 Sealing Ducts in Large Commercial Buildings with Aerosolized Sealant Particles M. P. Modera, O. Brzozowski ** , F. R. Carrié * , D. J. Dickerhoff, W. W. Delp, W. J. Fisk, R. Levinson, D. Wang Abstract Electricity energy savings potential by eliminating air leakage from ducts in large commercial buildings is on the order of 10 kWh/m 2 per year (1 kWh/ft 2 ). We have tested, in two large commercial buildings, a new technology that simultaneously seals duct leaks and measures effective leakage area of ducts. The technology is based upon injecting a fog of aerosolized sealant particles into a pressurized duct system. In brief, this process involves blocking all of the intentional openings in a duct system (e.g., diffusers). Therefore, when the system is pressurized, the only place for the air carrying the aerosol

15

Performance of thermal distribution systems in large commercial buildings  

NLE Websites -- All DOE Office Websites (Extended Search)

Performance of thermal distribution systems in large commercial buildings Performance of thermal distribution systems in large commercial buildings Title Performance of thermal distribution systems in large commercial buildings Publication Type Journal Article LBNL Report Number LBNL-44331 Year of Publication 2002 Authors Xu, Tengfang T., François Rémi Carrié, Darryl J. Dickerhoff, William J. Fisk, Jennifer A. McWilliams, Duo Wang, and Mark P. Modera Journal Energy and Buildings Volume 34 Start Page Chapter Pagination 215-226 Abstract This paper presents major findings of a field study on the performance of five thermal distribution systems in four large commercial buildings. The five systems studied are typical single-duct or dual-duct constant air volume (CAV) systems and variable air volume (VAV) systems, each of which serves an office building or a retail building with floor area over 2,000 m2. The air leakage from ducts are reported in terms of effective leakage area (ELA) at 25 Pa reference pressure, the ASHRAE-defined duct leakage class, and air leakage ratios. The specific ELAs ranged from 0.7 to 12.9 cm2 per m2 of duct surface area, and from 0.1 to 7.7 cm2 per square meter of floor area served. The leakage classes ranged from 34 to 757 for the five systems and systems sections tested. The air leakage ratios are estimated to be up to one-third of the fan- supplied airflow in the constant-air-volume systems. The specific ELAs and leakage classes indicate that air leakage in large commercial duct systems varies significantly from system to system, and from system section to system section even within the same thermal distribution system. The duct systems measured are much leakier than the ductwork specified as "unsealed ducts" by ASHRAE. Energy losses from supply ducts by conduction (including convection and radiation) are found to be significant, on the scale similar to the losses induced by air leakage in the duct systems. The energy losses induced by leakage and conduction suggest that there are significant energy-savings potentials from duct-sealing and insulation practice in large commercial buildings

16

Sealing Ducts in Large Commercial Buildings with Aerosolized Sealant  

NLE Websites -- All DOE Office Websites (Extended Search)

Sealing Ducts in Large Commercial Buildings with Aerosolized Sealant Sealing Ducts in Large Commercial Buildings with Aerosolized Sealant Particles Title Sealing Ducts in Large Commercial Buildings with Aerosolized Sealant Particles Publication Type Journal Article LBNL Report Number LBNL-42414 Year of Publication 2001 Authors Modera, Mark P., Olivier Brzozowski, François Rémi Carrié, Darryl J. Dickerhoff, William W. Delp, William J. Fisk, Ronnen M. Levinson, and Duo Wang Journal Energy & Buildings Volume 34 Start Page Chapter Pagination 705-714 Abstract Electricity energy savings potential by eliminating air leakage from ducts in large commercial buildings is on the order of 10 kWh/m2 per year (1 kWh/ft2). We have tested, in two large commercial buildings, a new technology that simultaneously seals duct leaks and measures effective leakage area of ducts. The technology is based upon injecting a fog of aerosolized sealant particles into a pressurized duct system. In brief, this process involves blocking all of the intentional openings in a duct system (e.g., diffusers). Therefore, when the system is pressurized, the only place for the air carrying the aerosol particles to exit the system is through the leaks. The key to the technology is to keep the particles suspended within the airstream until they reach the leaks, and then to have them leave the airstream and deposit on the leak sites. The principal finding from this field study was that the aerosol technology is capable of sealing the leaks in a large commercial building duct system within a reasonable time frame. In the first building, 66% of the leakage area was sealed within 2.5 hours of injection, and in the second building 86% of the leakage area was sealed within 5 hours. We also found that the aerosol could be blown through the VAV boxes in the second building without impacting their calibrations or performance. Some remaining questions are (1) how to achieve sealing rates comparable to those experienced in smaller residential systems; and (2) what tightness level these ducts systems can be brought to by means of aerosol sealing.

17

Duct Leakage Impacts on VAV System Performance in Large Commercial  

NLE Websites -- All DOE Office Websites (Extended Search)

Duct Leakage Impacts on VAV System Performance in Large Commercial Duct Leakage Impacts on VAV System Performance in Large Commercial Buildings Title Duct Leakage Impacts on VAV System Performance in Large Commercial Buildings Publication Type Report LBNL Report Number LBNL-53605 Year of Publication 2003 Authors Wray, Craig P., and Nance Matson Abstract The purpose of this study is to evaluate the variability of duct leakage impacts on air distribution system performance for typical large commercial buildings in California. Specifically, a hybrid DOE-2/TRNSYS sequential simulation approach was used to model the energy use of a low-pressure terminal-reheat variable-air-volume (VAV) HVAC system with six duct leakage configurations (tight to leaky) in nine prototypical large office buildings (representing three construction eras in three California climates where these types of buildings are common). Combined fan power for the variable-speed-controlled supply and return fans at design conditions was assumed to be 0.8 W/cfm. The VAV system that we simulated had perfectly insulated ducts, and maintained constant static pressure in the ducts upstream of the VAV boxes and a constant supply air temperature at the air-handler. Further evaluations of duct leakage impacts should be carried out in the future after methodologies are developed to deal with duct surface heat transfer effects, to deal with airflows entering VAV boxes from ceiling return plenums (e.g., to model parallel fan-powered VAV boxes), and to deal with static pressure reset and supply air temperature reset strategies.

18

Demand Shifting With Thermal Mass in Large Commercial Buildings: Case  

NLE Websites -- All DOE Office Websites (Extended Search)

Demand Shifting With Thermal Mass in Large Commercial Buildings: Case Demand Shifting With Thermal Mass in Large Commercial Buildings: Case Studies and Tools Speaker(s): Peng Xu Date: March 9, 2007 - 12:00pm Location: 90-3122 The idea of pre-cooling and demand limiting is to pre-cool buildings at night or in the morning during off-peak hours, storing cooling energy in the building thermal mass and thereby reducing cooling loads during the peak periods. Savings are achieved by reducing on-peak energy and demand charges. The potential for utilizing building thermal mass for load shifting and peak demand reduction has been demonstrated in a number of simulation, laboratory, and field studies. Case studies in a number of office buildings in California has found that a simple demand limiting strategy reduced the chiller power by 20-100% (0.5-2.3W/ft2) during six

19

Criticality concerns in cleaning large uranium hexafluoride cylinders  

SciTech Connect

Cleaning large cylinders used to transport low-enriched uranium hexafluoride (UF{sub 6}) presents several challenges to nuclear criticality safety. This paper presents a brief overview of the cleaning process, the criticality controls typically employed and their bases. Potential shortfalls in implementing these controls are highlighted, and a simple example to illustrate the difficulties in complying with the Double Contingency Principle is discussed. Finally, a summary of recommended criticality controls for large cylinder cleaning operations is presented.

Sheaffer, M.K.; Keeton, S.C.; Lutz, H.F.

1995-06-01T23:59:59.000Z

20

Commercial Reference Building: Large Office | OpenEI  

Open Energy Info (EERE)

Office Office Dataset Summary Description Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus simulation software. Included here is data pertaining to the reference building type Large office for each of the 16 climate zones, and each of three construction categories: new construction, post-1980 construction existing buildings, pre-1980 construction existing buildings.The dataset includes four key components: building summary, zone summary, location summary and a picture. Building summary includes details about: form, fabric, and HVAC. Zone summary includes details such as: area, volume, lighting, and occupants for all types of zones in the building. Location summary includes key building information as it pertains to each climate zone, including: fabric and HVAC details, utility costs, energy end use, and peak energy demand.In total, DOE developed 16 reference building types that represent approximately 70% of commercial buildings in the U.S.; for each type, building models are available for each of the three categories. The commercial reference buildings (formerly known as commercial building benchmark models) were developed by the U.S. Department of Energy (DOE), in conjunction with three of its national laboratories.Additional data is available directly from DOE's Energy Efficiency & Renewable Energy (EERE) Website, including EnergyPlus software input files (.idf) and results of the EnergyPlus simulations (.html).

Note: This page contains sample records for the topic "large commercial critical" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Commercial Reference Building: Large Hotel | OpenEI  

Open Energy Info (EERE)

Hotel Hotel Dataset Summary Description Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus simulation software. Included here is data pertaining to the reference building type Large Hotel for each of the 16 climate zones, and each of three construction categories: new construction, post-1980 construction existing buildings, pre-1980 construction existing buildings.The dataset includes four key components: building summary, zone summary, location summary and a picture. Building summary includes details about: form, fabric, and HVAC. Zone summary includes details such as: area, volume, lighting, and occupants for all types of zones in the building. Location summary includes key building information as it pertains to each climate zone, including: fabric and HVAC details, utility costs, energy end use, and peak energy demand.In total, DOE developed 16 reference building types that represent approximately 70% of commercial buildings in the U.S.; for each type, building models are available for each of the three construction categories. The commercial reference buildings (formerly known as commercial building benchmark models) were developed by the U.S. Department of Energy (DOE), in conjunction with three of its national laboratories.Additional data is available directly from DOE's Energy Efficiency & Renewable Energy (EERE) Website, including EnergyPlus software input files (.idf) and results of the EnergyPlus simulations (.html).

22

Commercialization analysis of large wind energy conversion systems. Final report  

DOE Green Energy (OSTI)

The framework is described that can be used to evaluate potential new federal incentives to facilitate the market acceptance of utility-scale wind energy conversion systems. The insights gained from utilizing this framework to evaluate a variety of hypothetical federal incentives are discussed. The heart of the evaluation framework is an explicit representation of the decisions made by utility purchasers, suppliers, and government agencies with respect to the utilization and fabrication of large wind energy conversion systems. The demand-side and supply-side aspects of the multiparty commercialization model are described, and the model's struture is explained. (LEW)

Boyd, D.W.; Buckley, O.E.; Haas, S.M.

1980-06-01T23:59:59.000Z

23

Nested cycles in large triangulations and crossing-critical graphs  

E-Print Network (OSTI)

We show that every sufficiently large plane triangulation has a large collection of nested cycles that either are pairwise disjoint, or pairwise intersect in exactly one vertex, or pairwise intersect in exactly two vertices. We apply this result to show that for each fixed positive integer $k$, there are only finitely many $k$-crossing-critical simple graphs of average degree at least six. Combined with the recent constructions of crossing-critical graphs given by Bokal, this settles the question of for which numbers $q>0$ there is an infinite family of $k$-crossing-critical simple graphs of average degree $q$.

Hernandez-Velez, Cesar; Thomas, Robin

2009-01-01T23:59:59.000Z

24

Comparison of emerging diagnostic tools for large commercial HVAC systems  

SciTech Connect

Diagnostic software tools for large commercial buildings are being developed to help detect and diagnose energy and other performance problems with building operations. These software applications utilize energy management control system (EMCS) trend log data. Due to the recent development of diagnostic tools, there has been little detailed comparison among the tools and a limited awareness of tool capabilities by potential users. Today, these diagnostic tools focus mainly on air handlers, but the opportunity exists for broadening the scope of the tools to include all major parts of heating, cooling, and ventilation systems in more detail. This paper compares several tools in the following areas: (1) Scope, intent, and background; (2) Data acquisition, pre-processing, and management; (3) Problems detected; (4) Raw data visualization; (5) Manual and automated diagnostic methods and (6) Level of automation. This comparison is intended to provide practitioners and researchers with a picture of the current state of diagnostic tools. There is tremendous potential for these tools to help improve commercial building energy and non-energy performance.

Friedman, Hannah; Piette, Mary Ann

2001-04-06T23:59:59.000Z

25

Southwest Gas Corporation - Large Commercial Energy-Efficiency...  

Open Energy Info (EERE)

Type Utility Rebate Program Applicable Sector Commercial Eligible Technologies Boilers, Steam Traps, Modular Burner Controls, Boiler Tune-Up, Trim Control Pad Active Incentive No...

26

Intelligent Buildings Series, Volume 1: Large Commercial Buildings  

Science Conference Proceedings (OSTI)

As utilities seek the means to manage supply and demand of electricity, they increasingly look to the demand-side for opportunities. Commercial and institutional buildings represent substantial electrical loads that account for approximately 30% of all electric power consumed in the United States. Given the right circumstances, these energy consumers can act as demand-side resources by reducing their electrical demand in response to conditions on the supply-side. While demand response applications in com...

2011-12-01T23:59:59.000Z

27

Range of Applicability and Bias Determination for Postclosure Criticality of Commercial Spent Nuclear Fuel  

SciTech Connect

The purpose of this calculation report, Range of Applicability and Bias Determination for Postclosure Criticality of Commercial Spent Nuclear Fuel, is to validate the computational method used to perform postclosure criticality calculations. The validation process applies the criticality analysis methodology approach documented in Section 3.5 of the Disposal Criticality Analysis Methodology Topical Report. The application systems for this validation consist of waste packages containing transport, aging, and disposal canisters (TAD) loaded with commercial spent nuclear fuel (CSNF) of varying assembly types, initial enrichments, and burnup values that are expected from the waste stream and of varying degree of internal component degradation that may occur over the 10,000-year regulatory time period. The criticality computational tool being evaluated is the general-purpose Monte Carlo N-Particle (MCNP) transport code. The nuclear cross-section data distributed with MCNP 5.1.40 and used to model the various physical processes are based primarily on the Evaluated Nuclear Data File/B Version VI (ENDF/B-VI) library. Criticality calculation bias and bias uncertainty and lower bound tolerance limit (LBTL) functions for CSNF waste packages are determined based on the guidance in ANSI/ANS 8.1-1998 (Ref. 4) and ANSI/ANS 8.17-2004 (Ref. 5), as described in Section 3.5.3 of Ref. 1. The development of this report is consistent with Test Plan for: Range of Applicability and Bias Determination for Postclosure Criticality. This calculation report has been developed in support of licensing activities for the proposed repository at Yucca Mountain, Nevada, and the results of the calculation may be used in the criticality evaluation for CSNF waste packages based on a conceptual TAD canister.

Radulescu, Georgeta [ORNL; Mueller, Don [ORNL; Goluoglu, Sedat [ORNL; Hollenbach, Daniel F [ORNL; Fox, Patricia B [ORNL

2007-10-01T23:59:59.000Z

28

SCALE-4 Analysis of LaSalle Unit 1 BWR Commercial Reactor Critical Configurations  

SciTech Connect

Five commercial reactor criticals (CRCs) for the LaSalle Unit 1 boiling-water reactor have been analyzed using KENO V.a, the Monte Carlo criticality code of the SCALE 4 code system. The irradiated fuel assembly isotopics for the criticality analyses were provided by the Waste Package Design team at the Yucca Mountain Project in the US, who performed the depletion calculations using the SAS2H sequence of SCALE 4. The reactor critical measurements involved two beginning-of-cycle and three middle-of-cycle configurations. The CRCs involved relatively low-cycle burnups, and therefore contained a relatively high gadolinium poison content in the reactor assemblies. This report summarizes the data and methods used in analyzing the critical configurations and assesses the sensitivity of the results to some of the modeling approximations used to represent the gadolinium poison distribution within the assemblies. The KENO V.a calculations, performed using the SCALE 44GROUPNDF5 ENDF/B-V cross-section library, yield predicted k{sub eff} values within about 1% {Delta}k/k relative to reactor measurements for the five CRCs using general 8-pin and 9-pin heterogeneous gadolinium poison pin assembly models.

Gauld, I.C.

2000-03-01T23:59:59.000Z

29

SCALE-4 Analysis of LaSalle Unit 1 BWR Commercial Reactor Critical Configuration  

Science Conference Proceedings (OSTI)

Five commercial reactor criticals (CRCs) for the LaSalle Unit 1 boiling-water reactor have been analyzed using KENO V.a, the Monte Carlo criticality code of the SCALE 4 code system. The irradiated fuel assembly isotopics for the criticality analyses were provided by the Waste Package Design team at the Yucca Mountain Project in the United States, who performed the depletion calculations using the SAS2H sequence of SCALE 4. The reactor critical measurements involved two beginning-of-cycle and three middle-of-cycle configurations. The CRCs involved relatively low-cycle burnups, and therefore contained a relatively high gadolinium poison content in the reactor assemblies. This report summarizes the data and methods used in analyzing the critical configurations and assesses the sensitivity of the results to some of the modeling approximations used to represent the gadolinium poison distribution within the assemblies. The KENO V.a calculations, performed using the SCALE 44GROUPNDF5 ENDF/B-V cross-section library, yield predicted k{sub eff} values within about 1% {Delta}k/k relative to reactor measurements for the five CRCs using general 8-pin and 9-pin heterogeneous gadolinium poison pin assembly models.

Gauld, I.C.

2000-03-16T23:59:59.000Z

30

Demand relief and weather sensitivity in large California commercial office buildings  

SciTech Connect

A great deal of research has examined the weather sensitivity of energy consumption in commercial buildings; however, the recent power crisis in California has given greater importance to peak demand. Several new load-shedding programs have been implemented or are under consideration. Historically, the target customers have been large industrial users who can reduce the equivalent load of several large office buildings. While the individual load reduction from an individual office building may be less significant, there is ample opportunity for load reduction in this area. The load reduction programs and incentives for industrial customers may not be suitable for commercial building owners. In particular, industrial customers are likely to have little variation in load from day to day. Thus a robust baseline accounting for weather variability is required to provide building owners with realistic targets that will encourage them to participate in load shedding programs.

Kinney, Satkartar; Piette, Mary Ann; Gu, Lixing; Haves, Philip

2001-05-01T23:59:59.000Z

31

Hierarchical extraction of critical area for shorts in very large ICs  

Science Conference Proceedings (OSTI)

This paper describes an algorithm for efficiently extracting critical area in large VLSI circuits. The algorithm, implemented to handle shorts between electrical nets, takes advantage of the available hierarchy in the layout description in order to speed-up ... Keywords: CREST software, IC design, VLSI, circuit layout CAD, critical area extraction, hierarchical extraction, integrated circuit layout, large VLSI circuits, layout description, shorts, very large ICs

P. K. Nag; W. Maly

1995-11-01T23:59:59.000Z

32

Thin Film CIGS and CdTe Photovoltaic Technologies: Commercialization, Critical Issues, and Applications; Preprint  

DOE Green Energy (OSTI)

We report here on the major commercialization aspects of thin-film photovoltaic (PV) technologies based on CIGS and CdTe (a-Si and thin-Si are also reported for completeness on the status of thin-film PV). Worldwide silicon (Si) based PV technologies continues to dominate at more than 94% of the market share, with the share of thin-film PV at less than 6%. However, the market share for thin-film PV in the United States continues to grow rapidly over the past several years and in CY 2006, they had a substantial contribution of about 44%, compared to less than 10% in CY 2003. In CY 2007, thin-film PV market share is expected to surpass that of Si technology in the United States. Worldwide estimated projections for CY 2010 are that thin-film PV production capacity will be more than 3700 MW. A 40-MW thin-film CdTe solar field is currently being installed in Saxony, Germany, and will be completed in early CY 2009. The total project cost is Euro 130 million, which equates to an installed PV system price of Euro 3.25/-watt averaged over the entire solar project. This is the lowest price for any installed PV system in the world today. Critical research, development, and technology issues for thin-film CIGS and CdTe are also elucidated in this paper.

Ullal, H. S.; von Roedern, B.

2007-09-01T23:59:59.000Z

33

Characterization of a commercially available large area, high detection efficiency single-photon avalanche diode  

E-Print Network (OSTI)

We characterize a new commercial, back-illuminated reach-through silicon single-photon avalanche photo diode (SPAD) SAP500 (Laser Components. Inc.), operated in Geiger-mode for purpose of photon counting. We show that for this sensor a significant interplay exists between dark counts, detection efficiency, afterpulsing, excess voltage and operating temperature, sometimes requiring a careful optimization tailored for a specific application. We find that a large flat plateau of sensitive area of about 0.5 mm in diameter, a peak quantum efficiency of 73% at 560 nm and timing precision down to 150 ps FWHM are the main distinguishing characteristics of this SPAD.

Stip?evi?, Mario; Ursin, Rupert

2013-01-01T23:59:59.000Z

34

Demand Shifting with Thermal Mass in Large Commercial Buildings in a  

NLE Websites -- All DOE Office Websites (Extended Search)

Shifting with Thermal Mass in Large Commercial Buildings in a Shifting with Thermal Mass in Large Commercial Buildings in a California Hot Climate Zone Title Demand Shifting with Thermal Mass in Large Commercial Buildings in a California Hot Climate Zone Publication Type Report LBNL Report Number LBNL-3898e Year of Publication 2009 Authors Xu, Peng, Rongxin Yin, Carrie Brown, and DongEun Kim Date Published June 2009 Publisher CEC/LBNL Keywords demand response, demand shifting (pre-cooling), DRQAT, hot climates, market sectors, office buildings, pre-cooling, technologies, testbed tools and guides, thermal mass Abstract The potential for using building thermal mass for load shifting and peak energy demand reduction has been demonstrated in a number of simulation, laboratory, and field studies. Previous Lawrence Berkeley National Laboratory research has demonstrated that the approach is very effective in cool and moderately warm climate conditions (California Climate Zones 2-4). However, this method had not been tested in hotter climate zones.This project studied the potential of pre-cooling the building early in the morning and increasing temperature setpoints during peak hours to reduce cooling-related demand in two typical office buildings in hotter California climates - one in Visalia (CEC Climate Zone 13) and the other in San Bernardino (CEC Climate Zone 10). The conclusion of the work to date is that pre-cooling in hotter climates has similar potential to that seen previously in cool and moderate climates. All other factors being equal, results to date indicate that pre-cooling increases the depth (kW) and duration (kWh) of the possible demand shed of a given building. The effectiveness of night pre-cooling in typical office building under hot weather conditions is very limited. However, night pre-cooling is helpful for office buildings with an undersized HVAC system. Further work is required to duplicate the tests in other typical buildings and in other hot climate zones and prove that pre-cooling is truly effective.

35

United States Department of Energy large commercial absorption chiller development program  

Science Conference Proceedings (OSTI)

The US Department of Energy (DOE) is working with partners from the gas cooling industry to improve energy efficiency and US competitiveness by using advanced absorption technologies that eliminate the use of chlorofluorocarbons (CFCs) and hydrochlorofluorocarbons (HCFCs), refrigerants that contribute to ozone depletion and global warming. Absorption cooling uses natural gas as the heat source, which produces much lower NO{sub x} emissions than oil- or coal-generated electricity. Gas-fired chillers also have the advantage of helping reduce peak electrical usage during summer months. To assist industry in developing advanced absorption cooling technologies, DOE sponsors the Large Commercial Chiller Development Program. The goal of the program is to improve chiller cooling efficiency by 30--50% compared with the best currently available absorption systems.

Garland, P.W.; DeVault, R.C.; Zaltash, A.

1998-11-01T23:59:59.000Z

36

Proceedings of the First International Workshop on Data Dissemination for Large Scale Complex Critical Infrastructures  

Science Conference Proceedings (OSTI)

Welcome to Valencia and to the first edition of the workshop on Data Distribution for Large-scale Complex Critical Infrastructures (DD4LCCI 2010). This workshop aims at providing a forum for researchers and engineers in academia and industry to foster ...

Christian Esposito; Aniruddha Gokhale; Domenico Cotroneo; Douglas C. Schmidt

2010-04-01T23:59:59.000Z

37

Plutonium Finishing Plant (PFP) Standby Power System Commercial Grade Item (CGI) Critical Characteristics  

SciTech Connect

PFP's Standby Power System consists of the diesel generators, the generator control system, Rm 308 UPS, switchgear batteries, and the electrical equipment used to distribute this power. Due to the nature of the equipment and its use throughout general industry, the majority of the system falls within the CGI definition HNF-PRO-268, ''Control of Purchased Items and Services'' and HNF-PRO-1819, ''PHMC Engineering Requirements'' require that the critical characteristics of CGI-procured equipment be established in an engineering document prior to placing the order. HNF-5043 established these critical characteristics for the Standby Power System. This modification adds several items to the document.

DEHKORDI, N.H.

2000-04-12T23:59:59.000Z

38

PFP Commercial Grade Food Pack Cans for Plutonium Handling and Storage Critical Characteristics  

SciTech Connect

This document specifies the critical characteristics for containers procured for Plutonium Finishing Plant's (PFP's) Vault Operations system as required by HNF-PRO-268 and HNF-PRO-1819. These are the minimum specifications that the equipment must meet in order to perform its safety function.

BONADIE, E.P.

2000-10-26T23:59:59.000Z

39

Duct leakage impacts on VAV system performance in California large commercial buildings  

SciTech Connect

The purpose of this study is to evaluate the variability of duct leakage impacts on air distribution system performance for typical large commercial buildings in California. Specifically, a hybrid DOE-2/TRNSYS sequential simulation approach was used to model the energy use of a low-pressure terminal-reheat variable-air-volume (VAV) HVAC system with six duct leakage configurations (tight to leaky) in nine prototypical large office buildings (representing three construction eras in three California climates where these types of buildings are common). Combined fan power for the variable-speed-controlled supply and return fans at design conditions was assumed to be 0.8 W/cfm. Based on our analyses of the 54 simulation cases, the increase in annual fan energy is estimated to be 40 to 50% for a system with a total leakage of 19% at design conditions compared to a tight system with 5% leakage. Annual cooling plant energy also increases by about 7 to 10%, but reheat energy decreases (about 3 to 10%). In combination, the increase in total annual HVAC site energy is 2 to 14%. The total HVAC site energy use includes supply and return fan electricity consumption, chiller and cooling tower electricity consumption, boiler electricity consumption, and boiler natural gas consumption. Using year 2000 average commercial sector energy prices for California ($0.0986/kWh and $7.71/Million Btu), the energy increases result in 9 to 18% ($7,400 to $9,500) increases in HVAC system annual operating costs. Normalized by duct surface area, the increases in annual operating costs are 0.14 to 0.18 $/ft{sup 2}. Using a suggested one-time duct sealing cost of $0.20 per square foot of duct surface area, these results indicate that sealing leaky ducts in VAV systems has a simple payback period of about 1.3 years. Even with total leakage rates as low as 10%, duct sealing is still cost effective. This suggests that duct sealing should be considered at least for VAV systems with 10% or more total duct leakage. The VAV system that we simulated had perfectly insulated ducts, and maintained constant static pressure in the ducts upstream of the VAV boxes and a constant supply air temperature at the airhandler. Further evaluations of duct leakage impacts should be carried out in the future after methodologies are developed to deal with duct surface heat transfer effects, to deal with airflows entering VAV boxes from ceiling return plenums (e.g., to model parallel fan-powered VAV boxes), and to deal with static pressure reset and supply air temperature reset strategies.

Wray, Craig P.; Matson, Nance E.

2003-10-01T23:59:59.000Z

40

Plutonium Finishing Plant (PFP) Standby Power System Commercial Grade Item (CGI) Critical Characteristics  

Science Conference Proceedings (OSTI)

PEP's Standby Power System consists of the diesel generators, the generator control system, Rm 308 UPS, switchgear batteries, and the electrical equipment used to distribute this power. Due to the nature of the equipment and its use throughout general industry, the majority of the system falls within the CGI definition HNF-PRO-268. ''Control of Purchased Items and Services'' and HNF-PRO-1819, ''PHMC Engineering Requirements'' require that the critical characteristics of CGI-procured equipment be established in an engineering document prior to placing the order. HNF-5043 establishes these critical characteristics for the Standby Power System. Equipment will be added to the list as required to support future CGI procurements.

BUSCH, M.S.

1999-09-16T23:59:59.000Z

Note: This page contains sample records for the topic "large commercial critical" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Parametric System Curves: Correlations Between Fan Pressure Rise and Flow for Large Commercial Buildings  

SciTech Connect

A substantial fraction of HVAC energy use in large commercial buildings is due to fan operation. Fan energy use depends in part on the relationship between system pressure drop and flow through the fan, which is commonly called a "system curve." As a step toward enabling better selections of air-handling system components and analyses of common energy efficiency measures such as duct static pressure reset and duct leakage sealing, this paper shows that a simple four-parameter physical model can be used to define system curves. Our model depends on the square of the fan flow, as is commonly considered. It also includes terms that account for linear-like flow resistances such as filters and coils, and for supply duct leakage when damper positions are fixed or are changed independently of static pressure or fan flow. Only two parameters are needed for systems with variable-position supply dampers (e.g., VAV box dampers modulating to control flow). For these systems, reducing or eliminating supply duct leakage does not change the system curve. The parametric system curve may be most useful when applied to field data. Non-linear techniques could be used to fit the curve to fan pressure rise and flow measurements over a range of operating conditions. During design, when measurements are unavailable, one could use duct design calculation tools instead to determine the coefficients.

Sherman, Max; Wray, Craig

2010-05-19T23:59:59.000Z

42

Development of Performance Acceptance Test Guidelines for Large Commercial Parabolic Trough Solar Fields: Preprint  

DOE Green Energy (OSTI)

Prior to commercial operation, large solar systems in utility-size power plants need to pass a performance acceptance test conducted by the EPC contractor or owners. In lieu of the present absence of engineering code developed for this purpose, NREL has undertaken the development of interim guidelines to provide recommendations for test procedures that can yield results of a high level of accuracy consistent with good engineering knowledge and practice. The fundamental differences between acceptance of a solar power plant and a conventional fossil-fired plant are the transient nature of the energy source and the necessity to utilize an analytical performance model in the acceptance process. These factors bring into play the need to establish methods to measure steady state performance, potential impacts of transient processes, comparison to performance model results, and the possible requirement to test, or model, multi-day performance within the scope of the acceptance test procedure. The power block and BOP are not within the boundaries of this guideline. The current guideline is restricted to the solar thermal performance of parabolic trough systems and has been critiqued by a broad range of stakeholders in CSP development and technology.

Kearney, D.; Mehos, M.

2010-12-01T23:59:59.000Z

43

Energy Savings Modeling of Standard Commercial Building Re-tuning Measures: Large Office Buildings  

SciTech Connect

Today, many large commercial buildings use sophisticated building automation systems (BASs) to manage a wide range of building equipment. While the capabilities of BASs have increased over time, many buildings still do not fully use the BAS's capabilities and are not properly commissioned, operated or maintained, which leads to inefficient operation, increased energy use, and reduced lifetimes of the equipment. This report investigates the energy savings potential of several common HVAC system retuning measures on a typical large office building prototype model, using the Department of Energy's building energy modeling software, EnergyPlus. The baseline prototype model uses roughly as much energy as an average large office building in existing building stock, but does not utilize any re-tuning measures. Individual re-tuning measures simulated against this baseline include automatic schedule adjustments, damper minimum flow adjustments, thermostat adjustments, as well as dynamic resets (set points that change continuously with building and/or outdoor conditions) to static pressure, supply air temperature, condenser water temperature, chilled and hot water temperature, and chilled and hot water differential pressure set points. Six combinations of these individual measures have been formulated - each designed to conform to limitations to implementation of certain individual measures that might exist in typical buildings. All of these measures and combinations were simulated in 16 cities representative of specific U.S. climate zones. The modeling results suggest that the most effective energy savings measures are those that affect the demand-side of the building (air-systems and schedules). Many of the demand-side individual measures were capable of reducing annual HVAC system energy consumption by over 20% in most cities that were modeled. Supply side measures affecting HVAC plant conditions were only modestly successful (less than 5% annual HVAC energy savings for most cities for all measures). Combining many of the retuning measures revealed deep savings potential. Some of the more aggressive combinations revealed 35-75% reductions in annual HVAC energy consumption, depending on climate and building vintage.

Fernandez, Nicholas; Katipamula, Srinivas; Wang, Weimin; Huang, Yunzhi; Liu, Guopeng

2012-06-01T23:59:59.000Z

44

Energy and critical ionic-bond parameter of a 3D large-radius bipolaron  

Science Conference Proceedings (OSTI)

A theory of a strong-coupling large-radius bipolaron has been developed. The possibility of the formation of 3D bipolarons in high-temperature superconductors is discussed. For the bipolaron energy, the lowest variational estimate has been obtained at {alpha} > 8, where {alpha} is the electron-phonon coupling constant. The critical ionic-bond parameter {eta}{sub c} = {epsilon}{sub {infinity}/{epsilon}0}, where {epsilon}{sub {infinity}} and {epsilon}{sub 0} are the high-frequency and static dielectric constants, has been found to be {eta}{sub c} = 0.2496.

Lakhno, V. D., E-mail: lak@impb.psn.r [Russian Academy of Sciences, Institute of Mathematical Problems of Biology (Russian Federation)

2010-05-15T23:59:59.000Z

45

Estimating Demand Response Market Potential Among Large Commercial and Industrial Customers: A Scoping Study  

E-Print Network (OSTI)

residential customers with peak demand greater than 350 kWs) Eligible Customers (peak demand) Optional hourly pricingis relatively small; the peak demand of its large, non-

Goldman, Charles; Hopper, Nicole; Bharvirkar, Ranjit; Neenan, Bernie; Cappers, Peter

2007-01-01T23:59:59.000Z

46

Characterization of Aircraft Icing Environments with Supercooled Large Drops for Application to Commercial Aircraft Certification  

Science Conference Proceedings (OSTI)

Observations of aircraft icing environments that included supercooled large drops (SLD) greater than 100 ?m in diameter have been analyzed. The observations were collected by instrumented research aircraft from 134 flights during six field ...

Stewart G. Cober; George A. Isaac

2012-02-01T23:59:59.000Z

47

Assessing the Vulnerability of Large Critical Infrastructure Using Fully-Coupled Blast Effects Modeling  

Science Conference Proceedings (OSTI)

Structural failures, such as the MacArthur Maze I-880 overpass in Oakland, California and the I-35 bridge in Minneapolis, Minnesota, are recent examples of our national infrastructure's fragility and serve as an important reminder of such infrastructure in our everyday lives. These two failures, as well as the World Trade Center's collapse and the levee failures in New Orleans, highlight the national importance of protecting our infrastructure as much as possible against acts of terrorism and natural hazards. This paper describes a process for evaluating the vulnerability of critical infrastructure to large blast loads using a fully-coupled finite element approach. A description of the finite element software and modeling technique is discussed along with the experimental validation of the numerical tools. We discuss how such an approach can be used for specific problems such as modeling the progressive collapse of a building.

McMichael, L D; Noble, C R; Margraf, J D; Glascoe, L G

2009-03-26T23:59:59.000Z

48

Barriers to commercialization of large-scale solar electricity: Lessions learned from the LUZ experience  

DOE Green Energy (OSTI)

This report discusses the economic and policy factors leading to the initial successful introduction of Luz International Limited`s Solar Electric Generating Systems (SEGS). It then addresses the wide range of barriers to continued SEGS commercialization, including state and federal tax policy, avoided cost energy pricing, artificial size limitations under the Public Utility Regulatory Policies Act (PURPA), the loss of effectiveness of PURPA itself, the lack of incentives available to utilities as owners of solar electric plants, and the limited ways in which the environmental benefits of this technology have been recognized. The way in which each of these barriers contributed to the suspension of new LUZ projects is highlighted. In addition, mitigation approaches to each of these barriers are suggested.

Lotker, M. [Lotker (Michael), Westlake Village, CA (United States)

1991-11-01T23:59:59.000Z

49

An evaluation of savings and measure persistence fromretrocommissioning of large commercial buildings  

SciTech Connect

Commercial building retrocommissioning activity has increased in recent years. LBNL recently conducted a study of 8 participants in Sacramento Municipal Utility District's (SMUD) retrocommissioning program. We evaluated the persistence of energy savings and measure implementation, in an effort to identify and understand factors that affect the longevity of retrocommissioning benefits. The LBNL analysis looked at whole-building energy and the retrocommissioning measure implementation status, incorporating elements from previous work by Texas A&M University and Portland Energy Conservation Inc. When possible, adjustments due to newly discovered major end uses, occupancy patterns and 2001 energy crisis responses were included in the whole-building energy analysis. The measure implementation analysis categorized each recommended measure and tracked the measures to their current operational status. Results showed a 59% implementation rate of recommended measures. The whole-building energy analysis showed an aggregate electricity savings of approximately 10.5% in the second post-retrocommissioning year, diminishing to approximately 8% in the fourth year. Results also showed the 2001 energy crisis played a significant role in the post-retrocommissioning energy use at the candidate sites. When natural gas consumption was included in the analysis, savings were reduced slightly, showing the importance in considering interactive effects between cooling and heating systems. The cost effectiveness of retrocommissioning was very attractive at the sites studied. However, funding for retrocommissioning activities is still very constrained.

Bourassa, Norman J.; Piette, Mary Ann; Motegi, Naoya

2004-03-10T23:59:59.000Z

50

Indoor Conditions Study and Impact on the Energy Consumption for a Large Commercial Building  

E-Print Network (OSTI)

This study is focused on the analysis of indoor conditions for a new commercial building that will be constructed in an East-European country. Based on the initial HVAC design parameters the surface of the building was divided in thermal zones that were studied using dynamic simulations. The article provides interesting insights of the building indoor conditions (summer/winter comfort), humidity, air temperature, mean operative temperature and energy consumption using hourly climate data. A dynamic variation of the PMV (Predicted Mean Vote Index) was obtained for different thermal zones of the building (retails stores, mall circulation, corridors) and in most of the cases the acceptable values of plus/minus 0.5 are exceeded. Among the most important energy efficiency measures it is mentioned a decrease of the heating set point temperature, increase of the walls and roof thermal resistance and the use of a heat recovery on the ventilation system. In this work it is demonstrated how simple measures can enhance the indoor conditions and reduce the energy consumption for this kind of construction.

Catalina, T.

2011-01-01T23:59:59.000Z

51

An evaluation of savings and measure persistence fromretrocommissioning of large commercial buildings  

SciTech Connect

Commercial building retrocommissioning activity has increased in recent years. LBNL recently conducted a study of 8 participants in Sacramento Municipal Utility District's (SMUD) retrocommissioning program. We evaluated the persistence of energy savings and measure implementation, in an effort to identify and understand factors that affect the longevity of retrocommissioning benefits. The LBNL analysis looked at whole-building energy and the retrocommissioning measure implementation status, incorporating elements from previous work by Texas A&M University and Portland Energy Conservation Inc. When possible, adjustments due to newly discovered major end uses, occupancy patterns and 2001 energy crisis responses were included in the whole-building energy analysis. The measure implementation analysis categorized each recommended measure and tracked the measures to their current operational status. Results showed a 59% implementation rate of recommended measures. The whole-building energy analysis showed an aggregate electricity savings of approximately 10.5% in the second post-retrocommissioning year, diminishing to approximately 8% in the fourth year. Results also showed the 2001 energy crisis played a significant role in the post-retrocommissioning energy use at the candidate sites. When natural gas consumption was included in the analysis, savings were reduced slightly, showing the importance in considering interactive effects between cooling and heating systems. The cost effectiveness of retrocommissioning was very attractive at the sites studied. However, funding for retrocommissioning activities is still very constrained.

Bourassa, Norman J.; Piette, Mary Ann; Motegi, Naoya

2004-03-10T23:59:59.000Z

52

Comparative guide to emerging diagnostic tools for large commercial HVAC systems  

Science Conference Proceedings (OSTI)

This guide compares emerging diagnostic software tools that aid detection and diagnosis of operational problems for large HVAC systems. We have evaluated six tools for use with energy management control system (EMCS) or other monitoring data. The diagnostic tools summarize relevant performance metrics, display plots for manual analysis, and perform automated diagnostic procedures. Our comparative analysis presents nine summary tables with supporting explanatory text and includes sample diagnostic screens for each tool.

Friedman, Hannah; Piette, Mary Ann

2001-05-01T23:59:59.000Z

53

Evaluation of Demand Shifting with Thermal Mass in Two Large Commercial Buildings  

SciTech Connect

Building thermal mass can be used to reduce the peak cooling load. For example, in summer, the building mass can be pre-cooled during non-peak hours in order to reduce the cooling load in the peak hours. As a result, the cooling load is shifted in time and the peak demand is reduced. The building mass can be cooled most effectively during unoccupied hours because it is possible to relax the comfort constraints. While the benefits of demand shift are certain, different thermal mass discharge strategies result in different cooling load reduction and savings. The goal of an optimized discharge strategy is to maximize the thermal mass discharge and minimize the possibility of rebounds before the shed period ends. A series of filed tests were carefully planned and conducted in two commercial buildings in Northern California to investigate the effects of various precooling and demand shed strategies. Field tests demonstrated the potential of cooling load reduction in peak hours and importance of discharge strategies to avoid rebounds. EnergyPlus simulation models were constructed and calibrated to investigate different kind of recovery strategies. The results indicate the value of pre-cooling in maximizing the electrical shed in the on-peak period. The results also indicate that the dynamics of the shed need to be managed in order to avoid discharging the thermal capacity of the building too quickly, resulting in high cooling load and electric demand before the end of the shed period. An exponential trajectory for the zone set-point during the discharge period yielded good results and is recommended for practical implementation.

Xu, Peng

2006-08-01T23:59:59.000Z

54

Time behavior of a critical reactor pulsed with a large square wave source  

SciTech Connect

In a previous Naval Application memorandum, a discussion was given of what happens to the power level of a reactor when an instantaneous, very large neutron source is introduced. The motivation for the problem arises from the question of what happens when a nuclear bomb is detonated near a reactor powered missile. This present memorandum looks at the same problem as that which is discussed in the previous memorandum but in slightly more detail. The results obtained are essentially the same as those of the previous memorandum with somewhat more attention given to the nature of the assumptions made. The kinetics model used is the space-time separable, one delayed group model. Space-time separability is almost certainly a poor assumption in this case. When a very large neutron wavefront impinges on a reactor, the subsequent short time behavior can hardly be that predicted by this simple model. One would expect very large local power densities in one part of the core before another part would see anything unusual. The other assumption, one delayed group, is not necessary but makes the mathematics simpler and in view of the first assumption is probably quite acceptable. In spite of these simplifications the model gives results which should have,qualitative physical relevance.

Barnett, C.

1962-10-02T23:59:59.000Z

55

Is there a large risk of radiation A critical review of pessimistic claims  

SciTech Connect

A number of situations where it has been claimed that moderate radiation doses cause leukemia or other cancers are carefully reviewed. We look at cases in the United States, Great Britain, and the Soviet Union. Usually it can be demonstrated that there is an alternative, more probable, explanation for the effect seen. In several cases the authors of the papers have fallen into statistical traps. The most frequent is a posteriori selection of cohort boundaries in both space and time: a trap illustrated dramatically by Feynman. The next most common trap is to arbitrarily select one out of many ways of looking at the data, against which we were warned by Tippett. Several cohorts are compared with respect to the number of persons at risk, average dose, and the number of cancers expected. Of these, only the cohort of A-bomb survivors in Japan and the recently unclassified data on the very large occupational doses for early Soviet nuclear workers at Chelyabinsk provide evidence of clearly visible excess cancers.

Shihab-Eldin, A.; Shlyakhter, A.; Wilson, R. (Harvard Univ., Cambridge, MA (United States). Dept. of Physics)

1992-07-01T23:59:59.000Z

56

Is there a large risk of radiation? A critical review of pessimistic claims  

Science Conference Proceedings (OSTI)

A number of situations where it has been claimed that moderate radiation doses cause leukemia or other cancers are carefully reviewed. We look at cases in the United States, Great Britain, and the Soviet Union. Usually it can be demonstrated that there is an alternative, more probable, explanation for the effect seen. In several cases the authors of the papers have fallen into statistical traps. The most frequent is a posteriori selection of cohort boundaries in both space and time: a trap illustrated dramatically by Feynman. The next most common trap is to arbitrarily select one out of many ways of looking at the data, against which we were warned by Tippett. Several cohorts are compared with respect to the number of persons at risk, average dose, and the number of cancers expected. Of these, only the cohort of A-bomb survivors in Japan and the recently unclassified data on the very large occupational doses for early Soviet nuclear workers at Chelyabinsk provide evidence of clearly visible excess cancers.

Shihab-Eldin, A.; Shlyakhter, A.; Wilson, R. [Harvard Univ., Cambridge, MA (United States). Dept. of Physics

1992-07-01T23:59:59.000Z

57

Deep Production Well for Geothermal Direct-Use Heating of A Large Commercial Greenhouse, Radium Springs, Rio Grande Rift, New Mexico  

DOE Green Energy (OSTI)

Expansion of a large commercial geothermally-heated greenhouse is underway and requires additional geothermal fluid production. This report discusses the results of a cost-shared U.S. Department of Energy (DOE) and A.R. Masson, Inc. drilling project designed to construct a highly productive geothermal production well for expansion of the large commercial greenhouse at Radium Springs. The well should eliminate the potential for future thermal breakthrough from existing injection wells and the inducement of inflow from shallow cold water aquifers by geothermal production drawdown in the shallow reservoir. An 800 feet deep production well, Masson 36, was drilled on a US Bureau of Land Management (BLM) Geothermal Lease NM-3479 at Radium Springs adjacent to the A. R. Masson Radium Springs Farm commercial greenhouse 15 miles north of Las Cruces in Dona Ana County, New Mexico just west of Interstate 25 near the east bank of the Rio Grande. The area is in the Rio Grande rift, a tectonically-active region with high heat flow, and is one of the major geothermal provinces in the western United State.

James C. Witcher

2002-01-02T23:59:59.000Z

58

Commercial Performance  

NLE Websites -- All DOE Office Websites (Extended Search)

Commercial Performance Commercial Performance Objectives: To review the market potential for improvements in commercial building glazings, quantify the energy savings potentials, explore potential design solutions, and develop guidelines and tools for building designers so that systems are specified and used in an optimal manner. A special emphasis is placed on the daylighting performance of glazings in commercial buildings since lighting is the single largest energy end use and daylighting can improve both visual performance and the quality of the indoor space as well as saving energy. Technical Approach: This project has two major complementary elements. The first is the exploration and assessment of glazing performance in commercial buildings leading to development of design strategies that reduce unnecessary energy use. The final step is creating design guides and tools that make this design knowledge accessible to practitioners, typically carried out in partnership with others. Although the emphasis is energy impacts, e.g. annual energy use, the performance issues addressed in the guides and tools include all that impact the final glazing selection process, e.g. appearance, glare. The second element is an exploration of daylighting strategies for commercial buildings since lighting energy use is the major energy end use in most buildings. This work develops and evaluates new daylighting devices and designs, assesses performance in commercial buildings, and demonstrates system performance using test cells, test rooms and case study buildings. All energy-related aspects of the design solutions, as well as other critical performance issues, are addressed in this work. Results of this work are integrated into the guides and tools described above. Much of this work has been co-supported by utilities and has been carried on in conjunction with participants in an International Energy Agency Daylighting Task.

59

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

that are used for space conditioning of commercial and industrial buildings. The standards implemented in 2010 for small and large, air-cooled commercial package air...

60

Commercial Buildings  

NLE Websites -- All DOE Office Websites (Extended Search)

Exterior glass windows of office tower Commercial Buildings Commercial building systems research explores different ways to integrate the efforts of research in windows, lighting,...

Note: This page contains sample records for the topic "large commercial critical" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Commercial Performance  

NLE Websites -- All DOE Office Websites (Extended Search)

Commercial Performance Objectives: To review the market potential for improvements in commercial building glazings, quantify the energy savings potentials, explore potential design...

62

Separation and Capture of CO2 from Large Stationary Sources and Sequestration in Geological Formations: A Summary of the 2003 Critical Review  

Science Conference Proceedings (OSTI)

Increasing amounts of carbon dioxide (CO2) in the atmosphere, and the resulting global warming effect, is a major air quality concern. CO2 is the most abundant greenhouse gas emitted by fossil-fuel combustion for power generation, transportation, and heating. Reducing worldwide emissions of CO2 will require many mitigation measures, including reductions in energy consumption, more efficient use of available energy, renewable energy sources, and carbon sequestration. The feasibility of capturing CO2 from large point sources and subsequent geological sequestration is the subject of this years Critical Review.

White, C.M.; Strazisar, B.R.; Granite, E.J.; Hoffman, J.S.; Pennline, H.W.

2003-06-01T23:59:59.000Z

63

Commercial Buildings  

NLE Websites -- All DOE Office Websites (Extended Search)

Links Commercial Building Ventilation and Indoor Environmental Quality Batteries and Fuel Cells Buildings Energy Efficiency Electricity Grid Energy Analysis Energy...

64

The ion acoustic decay instability in a large scale, hot plasma relevant to direct drive laser fusion -- Application to a critical surface diagnostic. Final report  

SciTech Connect

The authors have studied the ion acoustic decay instability in a large ({approximately} 1 mm) scale, hot ({approximately} 1 keV) plasma, which is relevant to a laser fusion reactor target. They have shown that the instability threshold is low. They have developed a novel collective Thomson scattering diagnostic at a 90{degree} scattering angle. The scattering is nonetheless coherent, because of the modest ratio of the frequency of the probe laser to that of the pump laser, such that even for such a large angle, (k{lambda}{sub De}){sup 2} is much less than one. With this system they have measured the electron plasma wave excited by the ion acoustic decay instability near the critical density (n{sub e} {approximately} 0.86 n{sub c}). This allows them to use the frequency of the detected wave to measure the electron temperature in the interaction region, obtaining a result reasonably close to that predicted by the SAGE computer code.

Mizuno, K.; DeGroot, J.S.; Drake, R.P.; Seka, W.; Craxton, R.S.; Estabrook, K.G.

1996-08-01T23:59:59.000Z

65

Commercial | Open Energy Information  

Open Energy Info (EERE)

Commercial Commercial Jump to: navigation, search Click to return to AEO2011 page AEO2011 Data From AEO2011 report . Market Trends The AEO2011 Reference case shows minimal change in commercial energy use per capita between 2009 and 2035 (Figure 62). While growth in commercial floorspace (1.2 percent per year) is faster than growth in population (0.9 percent per year), energy use per capita remains relatively steady due to efficiency improvements in equipment and building shells. Efficiency standards and the addition of more efficient technologies account for a large share of the improvement in the efficiency of end-use services, notably in space cooling, refrigeration, and lighting.[1] Issues in Focus In 2009, the residential and commercial buildings sectors used 19.6

66

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Small, Large, and Very Large, Air-Cooled Commercial Air Conditioning and Heating Equipment Sign up for e-mail updates on regulations for this and other products Pursuant to Section...

67

Criticality Model Report  

Science Conference Proceedings (OSTI)

The purpose of the ''Criticality Model Report'' is to validate the MCNP (CRWMS M&O 1998h) code's ability to accurately predict the effective neutron multiplication factor (k{sub eff}) for a range of conditions spanned by various critical configurations representative of the potential configurations commercial reactor assemblies stored in a waste package may take. Results of this work are an indication of the accuracy of MCNP for calculating eigenvalues, which will be used as input for criticality analyses for spent nuclear fuel (SNF) storage at the proposed Monitored Geologic Repository. The scope of this report is to document the development and validation of the criticality model. The scope of the criticality model is only applicable to commercial pressurized water reactor fuel. Valid ranges are established as part of the validation of the criticality model. This model activity follows the description in BSC (2002a).

J.M. Scaglione

2003-03-12T23:59:59.000Z

68

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Small, Large, and Very Large Commercial Package Air Conditioners and Heat Pumps Small, Large, and Very Large Commercial Package Air Conditioners and Heat Pumps Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) regulates the energy efficiency of small, large, and very large commercial package air conditioners and heat pumps. Commercial air conditioners and heat pumps are air-cooled, water-cooled, evaporatively-cooled, or water source unitary air conditioners or heat pumps that are used for space conditioning of commercial and industrial buildings. The standards implemented in 2010 for small and large, air-cooled commercial package air conditioners and heat pumps, and SPVUs, will save approximately 1.7 quads of energy and result in approximately $28.9 billion in energy bill savings for products shipped from 2010-2034. These standards will avoid about 90.3 million metric tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of 31.1 million automobiles. The standard implemented in 2010 for very large, air-cooled commercial package air conditioners and heat pumps will save approximately 0.43 quads of energy and result in approximately $4.3 billion in energy bill savings for products shipped from 2010-2034. The standard will avoid about 22.6 million metric tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of 4.4 million automobiles.

69

National Grid (Electric) - Large Commercial Energy Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

(HighLow Bay): 90 - 150fixture LEDs (Interior): 20-60fixture LEDs (Freezer CaseRefrigeration): 20-60fixture LEDs (GarageCanopy): 200fixture Lighting Controls...

70

CALIFORNIA ENERGY Large HVAC Building  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Large HVAC Building Survey Information Database of Buildings over 100 Design of Large Commercial HVAC Systems research project, one of six research elements in the Integrated Design of Large Commercial HVAC Systems Integrated Design of Small Commercial HVAC Systems Integrated

71

The ion acoustic decay instability, and anomalous laser light absorption for the OMEGA upgrade, large scale hot plasma application to a critical surface diagnostic, and instability at the quarter critical density. Final report  

SciTech Connect

It is shown that laser light can be anomalously absorbed with a moderate intensity laster (I{lambda}{sup 2}{approx}10{sup 14} W/cm{sup 2}-{mu}m{sup 2}) in a large scale, laser produced plasma. The heating regime, which is characterized by a relatively weak instability in a large region, is different from the regime studied previously, which is characterized by a strong instability in a narrow region. The two dimensional geometrical effect (lateral heating) has an important consequence on the anomalous electron heating. The characteristics of the IADI, and the anomalous absorption of the laser light were studied in a large scale, hot plasma applicable to OMEGA upgrade plasma. These results are important for the diagnostic application of the IADI.

Mizuno, K.; DeGroot, J.S.; Seka, W. [and others

1996-11-01T23:59:59.000Z

72

Range of Neutronic Parameters for Repository Criticality Analyses  

SciTech Connect

The ''Range of Neutronic Parameters for Repository Criticality Analyses'' technical report contains a summary of the benchmark criticality analyses (including the laboratory critical experiment [LCEs] and the commercial reactor criticals [CRCs]) used to support the validation of the criticality evaluation methods. This report also documents the development of the Critical Limits (CLs) for the repository criticality analyses.

W.J. Anderson

1999-09-28T23:59:59.000Z

73

Technology Commercialization & Partnerships | BNL  

Brookhaven National Laboratory's Office of Technology Commercialization and Partnerships manages and advances the commercialization of cutting-edge discoveries ...

74

CALIFORNIA ENERGY Large HVAC Energy Impact Report  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Large HVAC Energy Impact Report Statewide Energy Impact Report are part of the Integrated Design of Large Commercial HVAC Systems research project. The reports: Productivity and Interior Environments Integrated Design of Large Commercial HVAC Systems Integrated Design

75

Commercial Reference Buildings | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Buildings » Research Projects » Commercial Reference Buildings » Research Projects » Commercial Reference Buildings Commercial Reference Buildings The U.S. Department of Energy (DOE), in conjunction with three of its national laboratories, developed commercial reference buildings, formerly known as commercial building benchmark models. These reference buildings play a critical role in the program's energy modeling software research by providing complete descriptions for whole building energy analysis using EnergyPlus simulation software. There are 16 building types that represent approximately 70% of the commercial buildings in the U.S., according to the report published by the National Renewable Energy Laboratory titled U.S. Department of Energy Commercial Reference Building Models of the National Building Stock. These

76

Commercial Implementation of Model-Based Manufacturing of Nanostructured Metals  

SciTech Connect

Computational modeling is an essential tool for commercial production of nanostructured metals. Strength is limited by imperfections at the high strength levels that are achievable in nanostructured metals. Processing to achieve homogeneity at the micro- and nano-scales is critical. Manufacturing of nanostructured metals is intrinsically a multi-scale problem. Manufacturing of nanostructured metal products requires computer control, monitoring and modeling. Large scale manufacturing of bulk nanostructured metals by Severe Plastic Deformation is a multi-scale problem. Computational modeling at all scales is essential. Multiple scales of modeling must be integrated to predict and control nanostructural, microstructural, macrostructural product characteristics and production processes.

Lowe, Terry C. [Los Alamos National Laboratory

2012-07-24T23:59:59.000Z

77

Commercial Demand Module  

Gasoline and Diesel Fuel Update (EIA)

2 2 Commercial Demand Module The NEMS Commercial Sector Demand Module generates projections of commercial sector energy demand through 2035. The definition of the commercial sector is consistent with EIA's State Energy Data System (SEDS). That is, the commercial sector includes business establishments that are not engaged in transportation or in manufacturing or other types of industrial activity (e.g., agriculture, mining or construction). The bulk of commercial sector energy is consumed within buildings; however, street lights, pumps, bridges, and public services are also included if the establishment operating them is considered commercial. Since most of commercial energy consumption occurs in buildings, the commercial module relies on the data from the EIA

78

Entergy New Orleans - Small Commercial and Industrial Solutions Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Entergy New Orleans - Small Commercial and Industrial Solutions Entergy New Orleans - Small Commercial and Industrial Solutions Program Entergy New Orleans - Small Commercial and Industrial Solutions Program < Back Eligibility Commercial Industrial Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Home Weatherization Construction Commercial Weatherization Design & Remodeling Other Heat Pumps Appliances & Electronics Commercial Lighting Lighting Manufacturing Windows, Doors, & Skylights Maximum Rebate $50,000 or full cost of upgrade Program Info Funding Source New Orleans City Council State Louisiana Program Type Utility Rebate Program Rebate Amount Energy Assessment: Free Small Commercial Solutions Efficiency Improvements: $0.125 per kWh saved Large Commercial and Industrial Solutions Lighting Improvements: $0.10 per

79

El Paso Electric Company - Small Business and Commercial Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Small Business and Commercial Program Small Business and Commercial Program El Paso Electric Company - Small Business and Commercial Program < Back Eligibility Commercial Fed. Government Industrial Local Government Nonprofit State Government Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Other Heat Pumps Appliances & Electronics Commercial Lighting Lighting Home Weatherization Insulation Design & Remodeling Solar Buying & Making Electricity Program Info State Texas Program Type Utility Rebate Program Rebate Amount Large Commercial Solutions: $240/peak kW demand reduction Small Commercial Solutions: $400/kW demand reduction Provider El Paso Electric Company El Paso Electric (EPE) offers several incentive programs targeting small business owners as well as larger commercial and industrial EPE customers.

80

EERE: Commercialization & Deployment  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

marketplace. Commercialization Commercialization initiatives help bridge the gap between technology R&D and venture capital funding and marketing. Energy Innovation Portal...

Note: This page contains sample records for the topic "large commercial critical" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Commercialization Home Page - EERE Commercialization Office  

The Commercialization Team of the Office of Energy Efficiency and Renewable Energy (EERE) works to bridge the gap between research and development ...

82

Commercialization Home Page - EERE Commercialization Office  

The Commercialization Team of the Office of Energy Efficiency and Renewable Energy (EERE) works to bridge the gap between research and development (R&D), and venture ...

83

Criticality Model  

Science Conference Proceedings (OSTI)

The ''Disposal Criticality Analysis Methodology Topical Report'' (YMP 2003) presents the methodology for evaluating potential criticality situations in the monitored geologic repository. As stated in the referenced Topical Report, the detailed methodology for performing the disposal criticality analyses will be documented in model reports. Many of the models developed in support of the Topical Report differ from the definition of models as given in the Office of Civilian Radioactive Waste Management procedure AP-SIII.10Q, ''Models'', in that they are procedural, rather than mathematical. These model reports document the detailed methodology necessary to implement the approach presented in the Disposal Criticality Analysis Methodology Topical Report and provide calculations utilizing the methodology. Thus, the governing procedure for this type of report is AP-3.12Q, ''Design Calculations and Analyses''. The ''Criticality Model'' is of this latter type, providing a process evaluating the criticality potential of in-package and external configurations. The purpose of this analysis is to layout the process for calculating the criticality potential for various in-package and external configurations and to calculate lower-bound tolerance limit (LBTL) values and determine range of applicability (ROA) parameters. The LBTL calculations and the ROA determinations are performed using selected benchmark experiments that are applicable to various waste forms and various in-package and external configurations. The waste forms considered in this calculation are pressurized water reactor (PWR), boiling water reactor (BWR), Fast Flux Test Facility (FFTF), Training Research Isotope General Atomic (TRIGA), Enrico Fermi, Shippingport pressurized water reactor, Shippingport light water breeder reactor (LWBR), N-Reactor, Melt and Dilute, and Fort Saint Vrain Reactor spent nuclear fuel (SNF). The scope of this analysis is to document the criticality computational method. The criticality computational method will be used for evaluating the criticality potential of configurations of fissionable materials (in-package and external to the waste package) within the repository at Yucca Mountain, Nevada for all waste packages/waste forms. The criticality computational method is also applicable to preclosure configurations. The criticality computational method is a component of the methodology presented in ''Disposal Criticality Analysis Methodology Topical Report'' (YMP 2003). How the criticality computational method fits in the overall disposal criticality analysis methodology is illustrated in Figure 1 (YMP 2003, Figure 3). This calculation will not provide direct input to the total system performance assessment for license application. It is to be used as necessary to determine the criticality potential of configuration classes as determined by the configuration probability analysis of the configuration generator model (BSC 2003a).

A. Alsaed

2004-09-14T23:59:59.000Z

84

Consumers Energy (Electric) - Commercial Energy Efficiency Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Consumers Energy (Electric) - Commercial Energy Efficiency Program Consumers Energy (Electric) - Commercial Energy Efficiency Program Consumers Energy (Electric) - Commercial Energy Efficiency Program < Back Eligibility Commercial Fed. Government Industrial Local Government Multi-Family Residential Nonprofit State Government Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Manufacturing Other Construction Commercial Weatherization Heat Pumps Commercial Lighting Lighting Home Weatherization Windows, Doors, & Skylights Maximum Rebate Prescriptive: $100,000 per facility Custom: 50% of project cost and $200,000 per facility (100% of the calculated incentive up to $100,000 and 50% of the calculated incentive above $100,000) Large Gas Customer Incentive Limit: $25,000 Customer Incentive Limit: $500,000

85

Commercial Buildings Characteristics, 1992  

Science Conference Proceedings (OSTI)

Commercial Buildings Characteristics 1992 presents statistics about the number, type, and size of commercial buildings in the United States as well as their energy-related characteristics. These data are collected in the Commercial Buildings Energy Consumption Survey (CBECS), a national survey of buildings in the commercial sector. The 1992 CBECS is the fifth in a series conducted since 1979 by the Energy Information Administration. Approximately 6,600 commercial buildings were surveyed, representing the characteristics and energy consumption of 4.8 million commercial buildings and 67.9 billion square feet of commercial floorspace nationwide. Overall, the amount of commercial floorspace in the United States increased an average of 2.4 percent annually between 1989 and 1992, while the number of commercial buildings increased an average of 2.0 percent annually.

Not Available

1994-04-29T23:59:59.000Z

86

Sampling Methodologies for the Commercial Sector  

Science Conference Proceedings (OSTI)

Designing a survey sample that accurately mirrors the target population is a key step toward a much-needed understanding of the factors affecting commercial electricity use. This thorough exploration of new and familiar methodologies is based on experience with five recent, large-scale utility surveys of commercial customers.

1984-09-01T23:59:59.000Z

87

Commercial | OpenEI  

Open Energy Info (EERE)

Commercial Commercial Dataset Summary Description This dataset contains hourly load profile data for 16 commercial building types (based off the DOE commercial reference building models) and residential buildings (based off the Building America House Simulation Protocols). This dataset also includes the Residential Energy Consumption Survey (RECS) for statistical references of building types by location. Source Commercial and Residential Reference Building Models Date Released April 18th, 2013 (7 months ago) Date Updated July 02nd, 2013 (5 months ago) Keywords building building demand building load Commercial data demand Energy Consumption energy data hourly kWh load profiles Residential Data Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage

88

Commercialization | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercialization Commercialization Commercialization See an example of these steps in the commercialization process of Nickel Metal Hydride Batteries. See an example of these steps in the commercialization process of Nickel Metal Hydride Batteries. Commercialization is the process by which technologies and innovations developed in the lab make their way to market. By licensing patents or using Energy Department facilities, researchers from the private sector and academia are able to take advantage of federal investments into basic science research, while researchers are able to ensure that their discoveries have a life beyond the lab. The Energy Department also helps entrepreneurs, small business owners and

89

Average Commercial Price  

U.S. Energy Information Administration (EIA) Indexed Site

Residential Price Average Commercial Price Period: Monthly Annual Download Series History Download Series History Definitions, Sources & Notes Definitions, Sources & Notes...

90

Technology Commercialization and Partnerships |  

Staff Directory; BNL People Technology Commercialization & Partnerships. Home; For BNL Inventors; ... a nonprofit applied science and technology organization. ...

91

Contacts - EERE Commercialization Office  

Contacts. For more information about the National Clean Energy Business Plan Competition, or about other commercialization initiatives, please contact ...

92

Columbia Gas of Massachusetts - Commercial Energy Efficiency Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Columbia Gas of Massachusetts - Commercial Energy Efficiency Columbia Gas of Massachusetts - Commercial Energy Efficiency Program Columbia Gas of Massachusetts - Commercial Energy Efficiency Program < Back Eligibility Commercial Fed. Government Industrial Local Government Multi-Family Residential Nonprofit State Government Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Commercial Weatherization Other Manufacturing Appliances & Electronics Water Heating Maximum Rebate Multifamily and Small Business: $50,000 Large Business: $100,000 Scoping Study: $7,500 Program Info State Massachusetts Program Type Utility Rebate Program Rebate Amount Multifamily and Small Business: 50% of the qualified cost Large Business: 50% of the qualified cost and up to $7500 of the scoping study cost

93

Overview of Commercial Buildings, 2003 - Major Characteristics  

U.S. Energy Information Administration (EIA) Indexed Site

Major Characteristics of All Commercial Buildings in 2003 Major Characteristics of All Commercial Buildings in 2003 CBECS data are used to answer basic questions about the commercial buildings sector, such as: What types are there? How large are they? How old are they? and Where are they? Results from the 2003 CBECS show that: The commercial buildings sector is not dominated by a single building type. Office buildings, the most common type of commercial building, account for 17 percent of buildings, floorspace, and energy consumed. Commercial buildings range widely in size and smaller buildings are much more numerous than larger buildings. The smallest buildings (1,001 to 5,000 square feet) account for 53 percent of buildings, but consume only 11 percent of total energy. The largest buildings (those larger than 500,000 square feet)

94

Commercial Buildings Consortium  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial Buildings Consortium Commercial Buildings Consortium Sandy Fazeli National Association of State Energy Officials sfazeli@naseo.org; 703-299-8800 ext. 17 April 2, 2013 Supporting Consortium for the U.S. Department of Energy Net-Zero Energy Commercial Buildings Initiative 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: * Many energy savings opportunities in commercial buildings remain untapped, underserved by the conventional "invest-design-build- operate" approach * The commercial buildings sector is siloed, with limited coordination

95

Commercial Demand Module  

Gasoline and Diesel Fuel Update (EIA)

This page intentionally left blank This page intentionally left blank 39 U.S. Energy Information Administration | Assumptions to the Annual Energy Outlook 2011 Commercial Demand Module The NEMS Commercial Sector Demand Module generates projections of commercial sector energy demand through 2035. The definition of the commercial sector is consistent with EIA's State Energy Data System (SEDS). That is, the commercial sector includes business establishments that are not engaged in transportation or in manufacturing or other types of industrial activity (e.g., agriculture, mining or construction). The bulk of commercial sector energy is consumed within buildings; however, street lights, pumps, bridges, and public services are also included if the establishment operating them is considered commercial.

96

Entergy Arkansas - Commercial and Industrial Energy Efficiency Programs |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Entergy Arkansas - Commercial and Industrial Energy Efficiency Entergy Arkansas - Commercial and Industrial Energy Efficiency Programs Entergy Arkansas - Commercial and Industrial Energy Efficiency Programs < Back Eligibility Agricultural Commercial Industrial Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Other Heat Pumps Appliances & Electronics Commercial Lighting Lighting Manufacturing Windows, Doors, & Skylights Maximum Rebate Feasibility Study: 25% of cost Program Info State Arkansas Program Type Utility Rebate Program Rebate Amount Small Business Energy Solutions (under 100kW): $0.21 - $0.50/kwh first year savings Large Commercial/Industrial (Prescriptive): $0.09/kwh first year savings Large Commercial/Industrial (Custom): $0.07 - $0.15/kwh first year savings

97

ConEd (Electric) - Commercial and Industrial Energy Efficiency Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

ConEd (Electric) - Commercial and Industrial Energy Efficiency ConEd (Electric) - Commercial and Industrial Energy Efficiency Program ConEd (Electric) - Commercial and Industrial Energy Efficiency Program < Back Eligibility Commercial Industrial Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Home Weatherization Construction Commercial Weatherization Design & Remodeling Manufacturing Other Heat Pumps Appliances & Electronics Commercial Lighting Lighting Water Heating Maximum Rebate Large Commercial Energy Study: $50,000 (electric); $67,000 (combined with gas) Program Info Expiration Date 12/31/2015 State New York Program Type Utility Rebate Program Rebate Amount Lighting: Varies widely by type Small Business Energy Surveys: Free Small Business Equipment Upgrades: up to 70% of cost Large Commercial Energy Study: 50% of the cost

98

Lighting in Commercial Buildings, 1986  

Gasoline and Diesel Fuel Update (EIA)

6 Lighting in Commercial Buildings Lighting in Commercial Buildings --1986 Overview Full Report and Tables Detailed analysis of energy consumption for lighting for U.S. commercial...

99

Conservation screening curves to compare efficiency investments to power plants: Applications to commercial sector conservation programs  

E-Print Network (OSTI)

Energy Analysis 3 LILCO--Commercial Energy Audit 4Large Commercial Audit 7 SCE--Energy Management SurveysUtilities--Energy Check 5 SMUD--Small Commercial Audit 6

Koomey, Jonathan; Rosenfeld, Arthur H.; Gadgil, Ashok J.

2008-01-01T23:59:59.000Z

100

Transforming Commercial Building Operations  

NLE Websites -- All DOE Office Websites (Extended Search)

Transforming Commercial Building Operations Transforming Commercial Building Operations Transforming Commercial Building Operations Ron Underhill Pacific Northwest National Laboratory ronald.underhill@pnnl.gov (509)375-9765 April 4, 2013 2 | Building Technologies Office eere.energy.gov * Most buildings are not commissioned (Cx) before occupancy, including HVAC and lighting systems * Buildings often are poorly operated and maintained leading to significant energy waste of 5 to 20%, even when they have building automation systems (BASs)

Note: This page contains sample records for the topic "large commercial critical" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Transforming Commercial Building Operations  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Transforming Commercial Building Operations Transforming Commercial Building Operations Transforming Commercial Building Operations Ron Underhill Pacific Northwest National Laboratory ronald.underhill@pnnl.gov (509)375-9765 April 4, 2013 2 | Building Technologies Office eere.energy.gov * Most buildings are not commissioned (Cx) before occupancy, including HVAC and lighting systems * Buildings often are poorly operated and maintained leading to significant energy waste of 5 to 20%, even when they have building automation systems (BASs)

102

World Energy Projection System Plus Model Documentation: Commercial Model  

Reports and Publications (EIA)

This report documents the objectives, analytical approach and development of the World Energy Projection System Plus (WEPS+) Commercial Model. It also catalogues and describes critical assumptions, computational methodology, parameter estimation techniques, and model source code.

Brian Murphy

2011-09-29T23:59:59.000Z

103

Commercial Buildings Integration Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Buildings Buildings Integration Program Arah Schuur Program Manager arah.schuur@ee.doe.gov April 2, 2013 Building Technologies Office Program Peer Review 2 | Building Technologies Office eere.energy.gov Vision Commercial buildings are constructed, operated, renovated and transacted with energy performance in mind and net zero ready commercial buildings are common and cost-effective. Commercial Buildings Integration Program Mission Accelerate voluntary uptake of significant energy performance improvements in existing and new commercial buildings. 3 | Building Technologies Office eere.energy.gov BTO Goals: BTO supports the development and deployment of technologies and systems to reduce

104

Commercial New Construction  

Energy.gov (U.S. Department of Energy (DOE))

Efficiency Vermont offers support to encourage energy efficient design for new construction. Efficiency Vermont will provide support for new commercial buildings, including technical assistance at...

105

Commercial Buildings Integration Program  

NLE Websites -- All DOE Office Websites (Extended Search)

2013 Building Technologies Office Program Peer Review 2 | Building Technologies Office eere.energy.gov Vision Commercial buildings are constructed, operated, renovated and...

106

Commercial Buildings Characteristics 1992  

U.S. Energy Information Administration (EIA) Indexed Site

Buildings Characteristics 1992 Buildings Characteristics Overview Full Report Tables National and Census region estimates of the number of commercial buildings in the U.S. and...

107

Commercialization Info 080611  

sponsors of the research that led to the Invention; the inventors of the Licensed Patents; and their ... of funding for the development and commercialization:

108

Nuclear criticality information system  

SciTech Connect

The nuclear criticality safety program at LLNL began in the 1950's with a critical measurements program which produced benchmark data until the late 1960's. This same time period saw the rapid development of computer technology useful for both computer modeling of fissile systems and for computer-aided management and display of the computational benchmark data. Database management grew in importance as the amount of information increased and as experimental programs were terminated. Within the criticality safety program at LLNL we began at that time to develop a computer library of benchmark data for validation of computer codes and cross sections. As part of this effort, we prepared a computer-based bibliography of criticality measurements on relatively simple systems. However, it is only now that some of these computer-based resources can be made available to the nuclear criticality safety community at large. This technology transfer is being accomplished by the DOE Technology Information System (TIS), a dedicated, advanced information system. The NCIS database is described.

Koponen, B.L.; Hampel, V.E.

1981-11-30T23:59:59.000Z

109

Best Management Practice: Commercial Kitchen Equipment | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Best Management Practice: Commercial Kitchen Equipment Best Management Practice: Commercial Kitchen Equipment Best Management Practice: Commercial Kitchen Equipment October 8, 2013 - 9:42am Addthis Commercial kitchen equipment represents a large set of water users in the non-residential sector. Water efficiency for commercial kitchen equipment is especially important because high volume applications typically use mostly hot water. Ensuring commercial kitchen equipment uses water efficiently affords both significant water and energy savings. Water-using commercial kitchen equipment include pre-rinse spray valves, wash tanks and sinks, commercial dishwashers, food steamers, steam kettles, commercial ice makers, and combination ovens (combination oven/steamer). Operation and Maintenance To maintain water efficiency in operations and maintenance, Federal

110

Computers in Commercial Buildings  

U.S. Energy Information Administration (EIA) Indexed Site

has risen as well. The Annual Energy Outlook 2002 forecasts that commercial energy demand will grow at an average annual rate of 1.7 percent, with the most rapid increases in...

111

OpenEI - Commercial  

Open Energy Info (EERE)

are given by a location defined by the Typical Meteorological Year (TMY) for which the weather data was collected. Commercial load data is sorted by the (TMY) site as a...

112

Commercial Grade Dedication RM  

Energy.gov (U.S. Department of Energy (DOE))

The objective of this Standard Review Plan (SRP) on Commercial Grade Dedication (CGD) is to provide guidance for a uniform review of the CGD activities for office of Environmental Management...

113

1999 Commercial Buildings Characteristics  

U.S. Energy Information Administration (EIA) Indexed Site

Data Reports > 2003 Building Characteristics Overview Data Reports > 2003 Building Characteristics Overview 1999 Commercial Buildings Energy Consumption Survey—Commercial Buildings Characteristics Released: May 2002 Topics: Energy Sources and End Uses | End-Use Equipment | Conservation Features and Practices Additional Information on: Survey methods, data limitations, and other information supporting the data The 1999 Commercial Buildings Energy Consumption Survey (CBECS) was the seventh in the series begun in 1979. The 1999 CBECS estimated that 4.7 million commercial buildings (± 0.4 million buildings, at the 95% confidence level) were present in the United States in that year. Those buildings comprised a total of 67.3 (± 4.6) billion square feet of floorspace. Additional information on 1979 to 1999 trends

114

Regional hydrothermal commercialization plan  

SciTech Connect

This plan for the Rocky Mountain Basin and Range Region articulates the complete range of initiatives (federal, state, local, and industrial) required for the early commercialization of the regions geothermal resources. (MHR)

1978-07-14T23:59:59.000Z

115

Commercial Buildings Communications protocols  

Science Conference Proceedings (OSTI)

There are many automation and control protocols in use in commercial building and residential sectors today. For both commercial building and residential sectors there are several thousand manufacturers throughout the world that supply end-use electrical appliances and other building fixtures that communicate using these automation and control protocols. Some of these protocols are based on open standards (for example, BACnet, DALI) while others are semi-proprietary (for example, Zigbee, LonWorks, Modbus...

2008-05-15T23:59:59.000Z

116

Technology Commercialization Program 1991  

Science Conference Proceedings (OSTI)

This reference compilation describes the Technology Commercialization Program of the Department of Energy, Defense Programs. The compilation consists of two sections. Section 1, Plans and Procedures, describes the plans and procedures of the Defense Programs Technology Commercialization Program. The second section, Legislation and Policy, identifies legislation and policy related to the Program. The procedures for implementing statutory and regulatory requirements are evolving with time. This document will be periodically updated to reflect changes and new material.

Not Available

1991-11-01T23:59:59.000Z

117

ERC commercialization activities  

DOE Green Energy (OSTI)

The ERC family of companies is anticipating market entry of their first commercial product, a 2.8-MR power plant, in the second quarter of 1999. The present Cooperative Agreement provides for: (1) Commercialization planning and organizational development, (2) Completion of the pre-commercial DFC technology development, (3) Systems and plant design, (4) Manufacturing processes` scale-up to full- sized stack components and assemblies, (5) Upgrades to ERC`s test facility for full-sized stack testing, and (6) Sub-scale testing of a DFC Stack and BOP fueled with landfill gas. This paper discusses the first item, that of preparing for commercialization. ERC`s formal commercialization program began in 1990 with the selection of the 2-MR Direct Fuel Cell power plant by the American Public Power Association (APPA) for promotion to the over 2000 municipal utilities comprising APPA`s segment of the utility sector. Since that beginning, the APPA core group expanded to become the Fuel Cell Commercialization Group (FCCG) which includes representation from all markets - utilities and other power generation equipment buyers.

Maru, H.C.

1995-12-01T23:59:59.000Z

118

SOURCE OF BURNUP VALUES FOR COMMERCIAL SPENT NUCLEAR FUEL ASSEMBLIES  

SciTech Connect

Waste packages are loaded with commercial spent nuclear fuel (SNF) that satisfies the minimum burnup requirements of a criticality loading curve. The burnup value assigned by the originating nuclear utility to each SNF assembly (assigned burnup) is used to load waste packages in compliance with a criticality loading curve. The burnup provided by a nuclear utility has uncertainties, so conservative calculation methods are used to characterize those uncertainties for incorporation into the criticality loading curves. Procedural safety controls ensure that the correct assembly is loaded into each waste package to prevent a misload that could create a condition affecting the safety margins. Probabilistic analyses show that procedural safety controls can minimize the chance of a misload but can not completely eliminate the possibility. Physical measurements of burnup with instrumentation in the surface facility are not necessary due to the conservative calculation methods used to produce the criticality loading curves. The reactor records assigned burnup of a commercial SNF assembly contains about two percent uncertainty, which is increased to five-percent to ensure conservatism. This five-percent uncertainty is accommodated by adjusting the criticality loading curve. Also, the record keeping methods of nuclear utilities are not uniform and the level of detail required by the NRC has varied over the last several decades. Thus, some SNF assemblies may have assigned burnups that are averages for a batch of assemblies with similar characteristics. Utilities typically have access to more detailed core-follow records that allow the batch average burnup to be changed to an assembly specific burnup. Alternatively, an additional safety margin is incorporated into the criticality loading curve to accommodate SNF assemblies with batch average burnups or greater uncertainties due to the methodology used by the nuclear utility. The utility records provide the assembly identifier, initial {sup 235}U enrichment, and time of discharge from the reactor as well as the assigned burnup, but the distribution. of burnup axially along the assembly length is not provided. The axial burnup profile is maintained within acceptable bounds by the operating conditions of the nuclear reactor and is calculated during preparations to reload a reactor, but the actual burnup profile is not measured. The axial burnup profile is important to the determination of the reactivity of a waste package, so a conservative evaluation of the calculated axial profiles for a large database of SNF has been performed. The product of the axial profile evaluation is a profile that is conservative. Thus, there is no need for physical measurement of the axial profile. The assembly identifier is legible on each SNF assembly and the utility records provide the associated characteristics of the assembly. The conservative methodologies used to determine the criticality loading curve for a waste package provide sufficient margin so that criticality safety is assured for preclosure operations even in the event of a misload. Consideration of misload effects for postclosure time periods is provided by the criticality Features, Events, and Processes (FEPs) analysis. The conservative approaches used to develop and apply the criticality loading curve are thus sufficiently robust that the utility assigned burnup is an adequate source of burnup values, and additional means of verification of assigned burnup through physical measurements are not needed.

BSC

2004-12-01T23:59:59.000Z

119

Commercial integration and partnering at Savannah River Site  

Science Conference Proceedings (OSTI)

Savannah River Site (SRS), particularly the Savannah River Technology Center (SRTC) with the experience from the first successful Integrated Technology Demonstration, can provide an excellent foundation for meeting DOE-EM`s objectives with the new DOE-EM five focus area approach. With this in mind, SRTC established an activity to pursue full commercialization of environmental technologies. This report is an assessment of the status of commercialization at SRS and provides recommendations for enhancement as well as some tools critical to implementation. A review was made of the current situation at SRS with regards to taking technology development to commercial fruition. This was done from the perspective of comparing it to known commercialization models and processes. It was found that SRTC already works through many of the steps in these processes. With integration and action-oriented efforts of the inclusion of business and market factors, SRTC could become an aggressive, successful developer of commercialized technologies. Commercial success criteria tools were developed with regards to integrating them with SRTC selection criteria to ensure that all critical factors are covered in technology commercialization project evaluations. Private investors are very clear that their interest lies in funding commercial enterprises, not merely technologies. Mobilizing private capital is critical to real job growth and long-term economic development. Also, potential industry partners were identified that are willing to be involved with SRS` technology applications and regional development efforts. As another important component to success, regional support organizations were reviewed and evaluated.

Steele, J.R. [Westinghouse Savannah River Co., Aiken, SC (United States); Babione, R.A.; Shikashio, L.A.; Wacaster, A.J.; Paterson, A.D. [SCIENTECH, Inc., Idaho Falls, ID (United States)

1994-06-01T23:59:59.000Z

120

Idaho Power - Commercial Custom Efficiency Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Idaho Power - Commercial Custom Efficiency Program Idaho Power - Commercial Custom Efficiency Program Idaho Power - Commercial Custom Efficiency Program < Back Eligibility Commercial Industrial Institutional Local Government Nonprofit Schools State Government Tribal Government Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Manufacturing Other Appliances & Electronics Commercial Lighting Lighting Program Info Funding Source Conservation Program Funding Charge Energy Efficiency Riders State Oregon Program Type Utility Rebate Program Rebate Amount 0.12/kWh saved or 70% of project cost, whichever is less. Provider Idaho Power Company Large commercial and industrial Idaho Power customers that reduce energy usage through more efficient electrical commercial and industrial processes may qualify for an incentive that is the lesser of either 12 cents per

Note: This page contains sample records for the topic "large commercial critical" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Commercialization of Coal-to-Liquids Technology  

SciTech Connect

The report provides an overview of the current status of coal-to-liquids (CTL) commercialization efforts, including an analysis of efforts to develop and implement large-scale, commercial coal-to-liquids projects to create transportation fuels. Topics covered include: an overview of the history of coal usage and the current market for coal; a detailed description of what coal-to-liquids technology is; the history of coal-to-liquids development and commercial application; an analysis of the key business factors that are driving the increased interest in coal-to-liquids; an analysis of the issues and challenges that are hindering the commercialization of coal-to-liquids technology; a review of available coal-to-liquids technology; a discussion of the economic drivers of coal-to-liquids project success; profiles of key coal-to-liquids developers; and profiles of key coal-to-liquids projects under development.

NONE

2007-08-15T23:59:59.000Z

122

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

been required to comply with the Department of Energy's (DOE) energy conservation standards for commercial clothes washers since 2007. Commercial clothes washers use a water...

123

Jennifer Caldwell Senior Commercialization Manager  

NLE Websites -- All DOE Office Websites (Extended Search)

Caldwell, 865-574-4180, caldwelljt@ornl.gov Jennifer Caldwell Senior Commercialization Manager Jennifer Caldwell is a Senior Commercialization Manager for the Partnerships...

124

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

to comply with the Department of Energy's (DOE) energy conservation standards for commercial clothes washers since 2007. Commercial clothes washers use a water solution of soap,...

125

Tax Deductions for Commercial Buildings  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

of interest to businesses, including incen- tives for distributed generation and hybrid fuel fleet vehicles. Tax Deductions for Commercial Building Owners Commercial building...

126

Productive commercialization of university technology.  

E-Print Network (OSTI)

??Productive commercialization of university technology is a concern for the many stakeholders of the commercialization system. Do more total university research expenditures and more university (more)

Winder, Charles

2012-01-01T23:59:59.000Z

127

CALIFORNIA ENERGY Large HVAC Field and Baseline Data  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Large HVAC Field and Baseline Data Field Data Collection: Site Survey of the Integrated Design of Large Commercial HVAC Systems research project. The reports are a result of funding Design of Large Commercial HVAC Systems Integrated Design of Small Commercial HVAC Systems Integrated

128

AGING FACILITY CRITICALITY SAFETY CALCULATIONS  

Science Conference Proceedings (OSTI)

The purpose of this design calculation is to revise and update the previous criticality calculation for the Aging Facility (documented in BSC 2004a). This design calculation will also demonstrate and ensure that the storage and aging operations to be performed in the Aging Facility meet the criticality safety design criteria in the ''Project Design Criteria Document'' (Doraswamy 2004, Section 4.9.2.2), and the functional nuclear criticality safety requirement described in the ''SNF Aging System Description Document'' (BSC [Bechtel SAIC Company] 2004f, p. 3-12). The scope of this design calculation covers the systems and processes for aging commercial spent nuclear fuel (SNF) and staging Department of Energy (DOE) SNF/High-Level Waste (HLW) prior to its placement in the final waste package (WP) (BSC 2004f, p. 1-1). Aging commercial SNF is a thermal management strategy, while staging DOE SNF/HLW will make loading of WPs more efficient (note that aging DOE SNF/HLW is not needed since these wastes are not expected to exceed the thermal limits form emplacement) (BSC 2004f, p. 1-2). The description of the changes in this revised document is as follows: (1) Include DOE SNF/HLW in addition to commercial SNF per the current ''SNF Aging System Description Document'' (BSC 2004f). (2) Update the evaluation of Category 1 and 2 event sequences for the Aging Facility as identified in the ''Categorization of Event Sequences for License Application'' (BSC 2004c, Section 7). (3) Further evaluate the design and criticality controls required for a storage/aging cask, referred to as MGR Site-specific Cask (MSC), to accommodate commercial fuel outside the content specification in the Certificate of Compliance for the existing NRC-certified storage casks. In addition, evaluate the design required for the MSC that will accommodate DOE SNF/HLW. This design calculation will achieve the objective of providing the criticality safety results to support the preliminary design of the Aging Facility. As the ongoing design evolution remains fluid, the results from this design calculation should be evaluated for applicability to any new or modified design. Consequently, the results presented in this document are limited to the current design. The information contained in this document was developed by Environmental and Nuclear Engineering and is intended for the use of Design and Engineering in its work regarding the various criticality related activities performed in the Aging Facility. Yucca Mountain Project personnel from Environmental and Nuclear Engineering should be consulted before the use of the information for purposes other than those stated herein or use by individuals other than authorized personnel in Design and Engineering.

C.E. Sanders

2004-09-10T23:59:59.000Z

129

Thermal distribution systems in commercial buildings  

NLE Websites -- All DOE Office Websites (Extended Search)

Thermal distribution systems in commercial buildings Thermal distribution systems in commercial buildings Title Thermal distribution systems in commercial buildings Publication Type Journal Article LBNL Report Number LBNL-51860 Year of Publication 2003 Authors Diamond, Richard C., Craig P. Wray, Darryl J. Dickerhoff, Nance Matson, and Duo Wang Start Page Chapter Abstract Previous research suggests that HVAC thermal distribution systems in commercial buildings suffer from thermal losses, such as those caused by duct air leakage and poor duct location. Due to a lack of metrics and data showing the potentially large energy savings from reducing these losses, the California building industry has mostly overlooked energy efficiency improvements in this area. The purpose of this project is to obtain the technical knowledge needed to properly measure and understand the energy efficiency of these systems. This project has three specific objectives: to develop metrics and diagnostics for determining system efficiencies, to develop design and retrofit information that the building industry can use to improve these systems, and to determine the energy impacts associated with duct leakage airflows in an existing large commercial building. The primary outcome of this project is the confirmation that duct leakage airflows can significantly impact energy use in large commercial buildings: our measurements indicate that adding 15% duct leakage at operating conditions leads to an increase in fan power of about 25 to 35%. This finding is consistent with impacts of increased duct leakage airflows on fan power that have been predicted by previous simulations. Other project outcomes include the definition of a new metric for distribution system efficiency, the demonstration of a reliable test for determining duct leakage airflows, and the development of new techniques for duct sealing. We expect that the project outcomes will lead to new requirements for commercial thermal distribution system efficiency in future revisions of California's Title 24.

130

The Commercial Energy Consumer: About Whom Are We Speaking?  

SciTech Connect

Who are commercial sector customers, and how do they make decisions about energy consumption and energy efficiency investment? The energy policy field has not done a thorough job of describing energy consumption in the commercial sector. First, the discussion of the commercial sector itself is dominated by discussion of large businesses/buildings. Second, discussion of this portion of the commercial sectors consumption behavior is driven primarily by theory, with very little field data collected on the way commercial sector decision-makers describe their own options, choices, and reasons for taking action. These limitations artificially constrain energy policy options. This paper reviews the extant literature on commercial sector energy consumption behavior and identifies gaps in our knowledge. In particular, it argues that the primary energy policy model of commercial sector energy consumption is a top-down model that uses macro-level investment data to make conclusions about commercial behavior. Missing from the discussion is a model of consumption behavior that builds up to a theoretical framework informed by the micro-level data provided by commercial decision-makers themselves. Such a bottom-up model could enhance the effectiveness of commercial sector energy policy. In particular, translation of some behavioral models from the residential sector to the commercial sector may offer new opportunities for policies to change commercial energy consumption behavior. Utility bill consumption feedback is considered as one example of a policy option that may be applicable to both the residential and small commercial sector.

Payne, Christopher

2006-05-12T23:59:59.000Z

131

Average Commercial Price  

U.S. Energy Information Administration (EIA) Indexed Site

Citygate Price Residential Price Commercial Price Industrial Price Electric Power Price Gross Withdrawals Gross Withdrawals From Gas Wells Gross Withdrawals From Oil Wells Gross Withdrawals From Shale Gas Wells Gross Withdrawals From Coalbed Wells Repressuring Nonhydrocarbon Gases Removed Vented and Flared Marketed Production NGPL Production, Gaseous Equivalent Dry Production Imports By Pipeline LNG Imports Exports Exports By Pipeline LNG Exports Underground Storage Capacity Gas in Underground Storage Base Gas in Underground Storage Working Gas in Underground Storage Underground Storage Injections Underground Storage Withdrawals Underground Storage Net Withdrawals Total Consumption Lease and Plant Fuel Consumption Pipeline & Distribution Use Delivered to Consumers Residential Commercial Industrial Vehicle Fuel Electric Power Period: Monthly Annual

132

Average Commercial Price  

Gasoline and Diesel Fuel Update (EIA)

Citygate Price Residential Price Commercial Price Industrial Price Electric Power Price Gross Withdrawals Gross Withdrawals From Gas Wells Gross Withdrawals From Oil Wells Gross Withdrawals From Shale Gas Wells Gross Withdrawals From Coalbed Wells Repressuring Nonhydrocarbon Gases Removed Vented and Flared Marketed Production NGPL Production, Gaseous Equivalent Dry Production Imports By Pipeline LNG Imports Exports Exports By Pipeline LNG Exports Underground Storage Capacity Gas in Underground Storage Base Gas in Underground Storage Working Gas in Underground Storage Underground Storage Injections Underground Storage Withdrawals Underground Storage Net Withdrawals Total Consumption Lease and Plant Fuel Consumption Pipeline & Distribution Use Delivered to Consumers Residential Commercial Industrial Vehicle Fuel Electric Power Period: Monthly Annual

133

California commercial building energy benchmarking  

SciTech Connect

Building energy benchmarking is the comparison of whole-building energy use relative to a set of similar buildings. It provides a useful starting point for individual energy audits and for targeting buildings for energy-saving measures in multiple-site audits. Benchmarking is of interest and practical use to a number of groups. Energy service companies and performance contractors communicate energy savings potential with ''typical'' and ''best-practice'' benchmarks while control companies and utilities can provide direct tracking of energy use and combine data from multiple buildings. Benchmarking is also useful in the design stage of a new building or retrofit to determine if a design is relatively efficient. Energy managers and building owners have an ongoing interest in comparing energy performance to others. Large corporations, schools, and government agencies with numerous facilities also use benchmarking methods to compare their buildings to each other. The primary goal of Task 2.1.1 Web-based Benchmarking was the development of a web-based benchmarking tool, dubbed Cal-Arch, for benchmarking energy use in California commercial buildings. While there were several other benchmarking tools available to California consumers prior to the development of Cal-Arch, there were none that were based solely on California data. Most available benchmarking information, including the Energy Star performance rating, were developed using DOE's Commercial Building Energy Consumption Survey (CBECS), which does not provide state-level data. Each database and tool has advantages as well as limitations, such as the number of buildings and the coverage by type, climate regions and end uses. There is considerable commercial interest in benchmarking because it provides an inexpensive method of screening buildings for tune-ups and retrofits. However, private companies who collect and manage consumption data are concerned that the identities of building owners might be revealed and hence are reluctant to share their data. The California Commercial End Use Survey (CEUS), the primary source of data for Cal-Arch, is a unique source of information on commercial buildings in California. It has not been made public; however, it was made available by CEC to LBNL for the purpose of developing a public benchmarking tool.

Kinney, Satkartar; Piette, Mary Ann

2003-07-01T23:59:59.000Z

134

1999 Commercial Buildings Characteristics--Trends in Commercial Buildings  

U.S. Energy Information Administration (EIA) Indexed Site

Trends in Commercial Buildings and Floorspace Trends in Commercial Buildings and Floorspace Trends in Commercial Buildings and Floorspace The addition of commercial buildings and floorspace from 1995 to 1999 continued the general trends noted since 1979 (Figures 1 and 2). The size of the commercial buildings has grown steadily over the twenty years of CBECS. Each year more buildings are added to the sector (new construction or conversion of pre-existing buildings to commercial activity) than are removed (demolition or conversion to non-commercial activity). The definition for the commercial buildings population was changed for the 1995 CBECS which resulted in a slightly smaller buildings population and accounts for the data break in both Figures 1 and 2 (see report "Trends in the Commercial Buildings Sector" for complete details). Figure 1. Total Commercial Buildings, 1979 to 1999

135

IID Energy - Commercial Rebate Program (Commercial Check Me) | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

IID Energy - Commercial Rebate Program (Commercial Check Me) IID Energy - Commercial Rebate Program (Commercial Check Me) IID Energy - Commercial Rebate Program (Commercial Check Me) < Back Eligibility Commercial Savings Category Other Heating & Cooling Commercial Heating & Cooling Cooling Construction Commercial Weatherization Manufacturing Heat Pumps Appliances & Electronics Commercial Lighting Lighting Maximum Rebate General: $100,000 per customer per year; may not exceed 50% of the total installed cost of measures New Construction (Whole Building Approach - Owner): $150,000 per year New Construction (Whole Building Approach - Design Team): $30,000 per year New Construction (Systems Approach): $50,000 per year Program Info State California Program Type Utility Rebate Program Rebate Amount Programmable Thermostats: $50/unit

136

Building Technologies Office: Take Action to Save Energy in Commercial  

NLE Websites -- All DOE Office Websites (Extended Search)

in Commercial Buildings in Commercial Buildings Commercial building owners, operators and tenants can start saving energy today and use those cost savings for other critical parts of their businesses. The Building Technologies Office offers Commercial Buildings Resource Database and opportunities to partner with peers and technical experts. Photo of participants listening to a speaker at the Commercial Building Energy Alliances Executive Exchange with Commercial Building Stakeholders forum at the National Renewable Energy Laboratory (NREL) in Golden, Colorado, on May 24, 2012. Credit: Dennis Schroeder, NREL PIX 20913 Manage Organizational Energy Use Managing energy by creating a culture of efficiency throughout an organization can result in significant energy and monetary savings. Photo of NREL's Research Support Facility under construction, with two workers straddling I-beams.

137

Pathways to commercial success  

NLE Websites -- All DOE Office Websites (Extended Search)

HYDROGEN, FUEL CELLS & INFRASTRUCTURE HYDROGEN, FUEL CELLS & INFRASTRUCTURE TECHNOLOGIES (HFCIT) PROGRAM Pathways to Commercial Success: Technologies and Products Supported by the Hydrogen, Fuel Cells & Infrastructure Technologies Program August 2009 Prepared by Pacific Northwest National Laboratory for the U.S. Department of Energy Hydrogen, Fuel Cells & Infrastructure Technologies Program iii Table of Contents Summary .................................................................................................................................................................................................................. v 1.0 Introduction.......................................................................................................................................................................................................1-1

138

Commercial Sector Demand Module  

Reports and Publications (EIA)

Documents the objectives, analytical approach and development of the National Energy Modeling System (NEMS) Commercial Sector Demand Module. The report catalogues and describes the model assumptions, computational methodology, parameter estimation techniques, model source code, and forecast results generated through the synthesis and scenario development based on these components.

Kevin Jarzomski

2012-11-15T23:59:59.000Z

139

Commercial Sector Demand Module  

Reports and Publications (EIA)

Documents the objectives, analytical approach and development of the National Energy Modeling System (NEMS) Commercial Sector Demand Module. The report catalogues and describes the model assumptions, computational methodology, parameter estimation techniques, model source code, and forecast results generated through the synthesis and scenario development based on these components.

Kevin Jarzomski

2013-10-10T23:59:59.000Z

140

Energy Efficiency Fund (Electric) - Commercial and Industrial...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial and Industrial Energy Efficiency Programs Energy Efficiency Fund (Electric) - Commercial and Industrial Energy Efficiency Programs Eligibility Commercial Industrial...

Note: This page contains sample records for the topic "large commercial critical" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Commonwealth Solar Hot Water Commercial Program | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial Program Commonwealth Solar Hot Water Commercial Program Eligibility Agricultural Commercial Fed. Government Industrial Local Government Multi-Family Residential...

142

Coldwater Board of Public Utilities - Commercial & Industrial...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial & Industrial Lighting Rebate Program Coldwater Board of Public Utilities - Commercial & Industrial Lighting Rebate Program Eligibility Commercial Industrial Local...

143

Lakeland Electric - Commercial Conservation Rebate Program |...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial Conservation Rebate Program Lakeland Electric - Commercial Conservation Rebate Program Eligibility Commercial Fed. Government Industrial Local Government Nonprofit State...

144

Midstate Electric Cooperative - Commercial and Industrial Energy...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial and Industrial Energy Efficiency Rebate Program Midstate Electric Cooperative - Commercial and Industrial Energy Efficiency Rebate Program Eligibility Commercial...

145

Lane Electric Cooperative - Residential and Commercial Weatherization...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

and Commercial Weatherization Grant Program Lane Electric Cooperative - Residential and Commercial Weatherization Grant Program Eligibility Commercial Low-Income Residential...

146

Coast Electric Power Association - Commercial Energy Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial Energy Efficiency Rebate Program Coast Electric Power Association - Commercial Energy Efficiency Rebate Program Eligibility Commercial Savings For Heating & Cooling...

147

Golden Valley Electric Association - Commercial Lighting Retrofit...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial Lighting Retrofit Rebate Program Golden Valley Electric Association - Commercial Lighting Retrofit Rebate Program Eligibility Commercial Savings For Appliances &...

148

Site Map - EERE Commercialization Office  

Quick Links. Energy Innovation Portal; Site Map Commercialization Home Page. About. Success Stories; Legacy Initiatives

149

Large Energy Users Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Large Energy Users Program Large Energy Users Program Large Energy Users Program < Back Eligibility Commercial Fed. Government Industrial Institutional Local Government Nonprofit Schools State Government Savings Category Heating & Cooling Commercial Heating & Cooling Heating Cooling Home Weatherization Construction Commercial Weatherization Design & Remodeling Manufacturing Other Appliances & Electronics Heat Pumps Commercial Lighting Lighting Water Heating Maximum Rebate Prescriptive: Varies by equipment type Custom: $200,000 or 30% per project Total Prescriptive and Custom combined: $400,000 per calendar year Program Info Funding Source Focus On Energy Start Date 04/01/2012 Expiration Date 12/31/2013 State Wisconsin Program Type State Rebate Program Rebate Amount Prescriptive: Varies by equipment type

150

Aerogel commercialization pilot project. Final program report  

Science Conference Proceedings (OSTI)

Aerogels are extremely light weight, high surface area, very insulative materials that offer many potential improvements to commercial products. Aerogels have been the subject of extensive research at Department of Energy Laboratories and have been considered one of the technology most ready for commercialization. However, commercialization of the technology had been difficult for the National Laboratories since end users were not interested in the high temperature and high pressure chemical processes involved in manufacturing the raw material. Whereas, Aerojet as a supplier of rocket fuels, specialty chemicals and materials had the manufacturing facilities and experience to commercially produce aerogel-type products. Hence the TRP provided a link between the technology source (National Laboratories), the manufacturing (Aerojet) and the potential end users (other TRP partners). The program successfully produced approximately 500 ft{sup 2} of organic aerogel but failed to make significant quantities of silica aerogel. It is significant that this production represents both the largest volume and biggest pieces of organic aerogel ever produced. Aerogels, available from this program, when tested in several prototype commercial products were expected to improve the products performance, but higher than expected projected production costs for large scale manufacture of aerogels has limited continued commercial interest from these partners. Aerogels do, however, offer potential as a specialty material for some high value technology and defense products.

NONE

1996-02-13T23:59:59.000Z

151

Commercializing the H-Coal Process  

E-Print Network (OSTI)

The H-Coal Process is being demonstrated in commercial equipment at the Catlettsburg, Kentucky plant. A program is being developed for further operations including several tests for specific commercial projects and a long-term test. Over the last year, technical feasibility has been clearly demonstrated, but the economic matrix has been greatly altered. However, because of this alteration and because many countries outside the United States are more concerned about security of supply, Hydrocarbon Research, Inc. (HRI) has observed a decided swing in interest in commercial coal liquefaction. Project owners can select one of two paths for commercial coal liquefaction using H-Coal technology. The quantum strategy involves the construction of a large, independent facility and requires a very high initial capital investment. The incremental approach deals with stepwise additions of coal to a hydrogenation unit, may involve association with an existing facility, and will result in a substantially smaller initial investment. HRI's unique and commercially proven Liquid Phase Hydrogenation systems permit the owner to select the strategy most suited to his needs. The ultimate goals of commercial coal liquefaction can be reached by either route. The H-Coal program supports this goal.

DeVaux, G. R.; Dutkiewicz, B.

1982-01-01T23:59:59.000Z

152

About the Commercial Buildings Integration Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

About the Commercial Buildings Integration Program About the Commercial Buildings Integration Program About the Commercial Buildings Integration Program The Building Technologies Office (BTO) works to identify and develop strategies and technologies to dramatically reduce commercial building energy consumption. BTO's commercial building efforts focus on highly innovative, cost-effective, energy saving measures-ones that promise large energy savings at cost-effective levels, but are underutilized by the market. These efforts are carried out in collaboration with researchers at national laboratories and partners within industry with the goal of dramatically reducing new and existing commercial building energy consumption. Aggressive Energy Savings Goals BTO is targeting a 20% energy use reduction in commercial buildings by

153

ConEd (Gas) - Commercial and Industrial Energy Efficiency Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

ConEd (Gas) - Commercial and Industrial Energy Efficiency Program ConEd (Gas) - Commercial and Industrial Energy Efficiency Program ConEd (Gas) - Commercial and Industrial Energy Efficiency Program < Back Eligibility Commercial Industrial Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Commercial Weatherization Sealing Your Home Construction Design & Remodeling Manufacturing Other Appliances & Electronics Water Heating Maximum Rebate Large Commercial Energy Study: 50,000 (gas); 67,000 (combined with electric) VFD: 12,000 Program Info Expiration Date 12/31/2015 State New York Program Type Utility Rebate Program Rebate Amount Energy Study: 50% of the cost Custom: $1/therm at less than 20% savings; $2/therm at greater than 20% savings Control/Automation Systems: $2/therm saved, up to 50% of cost

154

TEP - Commercial Energy Efficiency Rebate Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

TEP - Commercial Energy Efficiency Rebate Program TEP - Commercial Energy Efficiency Rebate Program TEP - Commercial Energy Efficiency Rebate Program < Back Eligibility Commercial Fed. Government Industrial Local Government Nonprofit Schools State Government Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Home Weatherization Construction Commercial Weatherization Design & Remodeling Manufacturing Other Heat Pumps Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Large Business: up to 50%-75% of a measure's incremental cost New Construction: up to 50% of incremental cost of the energy efficient measures and up to $75,000 per project per year New Construction Design Work: up to 50% of the cost of the additional fees required for the energy efficient design and up to $10,000 per design team

155

Duct thermal performance models for large commercial buildings  

E-Print Network (OSTI)

the same time to the fan flow under design conditions; andat part-load fan operation as at design conditions. Thistime to the fan shaft power under design conditions; Part

Wray, Craig P.

2003-01-01T23:59:59.000Z

156

Comparison of emerging diagnostic tools for large commercial HVAC systems  

E-Print Network (OSTI)

contracting, design decision information, fan benchmarking,Fan Systems (UCB Tools), University of California at Berkeley, Center for Environmental Design

Friedman, Hannah; Piette, Mary Ann

2001-01-01T23:59:59.000Z

157

Performance of thermal distribution systems in large commercial buildings  

E-Print Network (OSTI)

sizing and design, e.g. , excessive fan-power requirement,fan-power and energy savings could be realized by better design

Xu, T.

2011-01-01T23:59:59.000Z

158

Web-based energy information systems for large commercial buildings  

SciTech Connect

Energy Information Systems (EIS), which monitor and organize building energy consumption and related trend data over the Internet, have been evolving over the past decade. This technology helps perform key energy management functions such as organizing energy use data, identifying energy consumption anomalies, managing energy costs, and automating demand response strategies. During recent years numerous developers and vendors of EIS have been deploying these products in a highly competitive market. EIS offer various software applications and services for a variety of purposes. Costs for such system vary greatly depending on the system's capabilities and how they are marketed. Some products are marketed directly to end users while others are made available as part of electric utility programs. EIS can be a useful tool in building commissioning and retro-commissioning. This paper reviews more than a dozen EIS. We have developed an analytical framework to characterize the main features of these products, which are developed for a variety of utility programs and end-use markets. The purpose of this research is to evaluate EIS capabilities and limitations, plus examine longer-term opportunities for utilizing such technology to improve building energy efficiency and load management.

Motegi, Naoya; Piette, Mary Ann

2003-03-29T23:59:59.000Z

159

Duct thermal performance models for large commercial buildings  

E-Print Network (OSTI)

London. 1964. C Compact Heat Exchangers, 2nd Edition, C NewLondon. 1964. C Compact Heat Exchangers, 2nd Ed. , McGraw- C

Wray, Craig P.

2003-01-01T23:59:59.000Z

160

Web-based energy information systems for large commercial buildings  

E-Print Network (OSTI)

Summary: Benchmark: Sub metering: Real-time: DRP bidding:interval meters, EMCS, and sub-metering, as described below.Sub DRP Real Remote Rate Summary download profile marking metering

Motegi, Naoya; Piette, Mary Ann

2003-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "large commercial critical" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Commercial Reference Building: Large Hotel

Open Energy Info (EERE)

descriptions for whole building energy analysis using

162

Large Scale Testing, Demonstration and Commercialization of the...  

NLE Websites -- All DOE Office Websites (Extended Search)

efficient components such as aluminum radiators (instead of stainless steel) and brass heat exchangers. FY 2012 Accomplishments Following are the accomplishments from...

163

Sealing Ducts in Large Commercial Buildings with Aerosolized Sealant Particles  

E-Print Network (OSTI)

of Diffusers Nominal Pre-Sealing Air Flow [L/s (cfm)] Tablepressurized with clean air during the sealing process. ) Theduring sealing. The objective is to maintain an air velocity

2001-01-01T23:59:59.000Z

164

Evaluation of retrocommissioning persistence in large commercial buildings  

E-Print Network (OSTI)

interactions Time Req. High BAS maint. Contract All of theit a PM plan). Office 6 hired a BAS expert with the task ofSMUD provided LBNL with 12 BAS (Building Automation Systems)

Bourassa, Norman J.; Piette, Mary Ann; Motegi, Naoya

2004-01-01T23:59:59.000Z

165

Comparison of emerging diagnostic tools for large commercial HVAC systems  

E-Print Network (OSTI)

handlers, cooling plants (cooling towers, chillers), heatingBoiler: see general Cooling tower (CT) capacity ENFORMA

Friedman, Hannah; Piette, Mary Ann

2001-01-01T23:59:59.000Z

166

Performance of thermal distribution systems in large commercial buildings  

E-Print Network (OSTI)

Air Leakage, and Heat Conduction Gains." Final Report ofof air leakage and heat conduction may lead to inappropriatethermal losses due to heat conduction through duct walls

Xu, T.

2011-01-01T23:59:59.000Z

167

Comparison of emerging diagnostic tools for large commercial HVAC systems  

E-Print Network (OSTI)

Manual Diagnostic Tools ENFORMA Portable Diagnostic Solutions (ENFORMA software), Architectural Energy Corporation (AEC) (

Friedman, Hannah; Piette, Mary Ann

2001-01-01T23:59:59.000Z

168

Large Commercial Wind Exemption and Alternative Taxes | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Not specified Program Information Start Date 7012007 (facility date of operation) South Dakota Program Type Property Tax Incentive Rebate Amount Alternative tax assessment...

169

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Showerheads Showerheads Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the water consumption level of showerheads since 1992. A showerhead is a perforated nozzle that distributes water over a large solid angle at point of use, generally overhead of the bather. They are used widely in residential and commercial settings. The current standard will save approximately 6 quads of energy and result in approximately $120 billion in energy bill savings for products shipped from 1994-2013. The standard will avoid about 329.2 million metric tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of about 64.5 million automobiles. The Standards and Test Procedures for this product are related to Rulemaking for Plumbing Products Test Procedure.

170

Average Commercial Price  

Gasoline and Diesel Fuel Update (EIA)

Pipeline and Distribution Use Price Citygate Price Residential Price Commercial Price Industrial Price Vehicle Fuel Price Electric Power Price Proved Reserves as of 12/31 Reserves Adjustments Reserves Revision Increases Reserves Revision Decreases Reserves Sales Reserves Acquisitions Reserves Extensions Reserves New Field Discoveries New Reservoir Discoveries in Old Fields Estimated Production Number of Producing Gas Wells Gross Withdrawals Gross Withdrawals From Gas Wells Gross Withdrawals From Oil Wells Gross Withdrawals From Shale Gas Wells Gross Withdrawals From Coalbed Wells Repressuring Nonhydrocarbon Gases Removed Vented and Flared Marketed Production Natural Gas Processed NGPL Production, Gaseous Equivalent Dry Production Imports By Pipeline LNG Imports Exports Exports By Pipeline LNG Exports Underground Storage Capacity Underground Storage Injections Underground Storage Withdrawals Underground Storage Net Withdrawals LNG Storage Additions LNG Storage Withdrawals LNG Storage Net Withdrawals Total Consumption Lease and Plant Fuel Consumption Lease Fuel Plant Fuel Pipeline & Distribution Use Delivered to Consumers Residential Commercial Industrial Vehicle Fuel Electric Power Period: Monthly Annual

171

Commercializing solar architecture  

SciTech Connect

The seminar discussions on attitudinal, technical, and institutional issues and the suggestions related to information development, acquisition, and dissemination; education and training; demonstrations and design competitions; and other actions are documented. Information on SERI's overall mission and a paper titled, The Architectural Role of SERI, and a matrix of barriers and actions from this assessment, related to the commercialization profile for passive solar heating, are attached as appendices.

Franta, G.

1979-03-01T23:59:59.000Z

172

Commercial equipment cost database  

SciTech Connect

This report, prepared for DOE, Office of Codes and Standards, as part of the Commercial Equipment Standards Program at Pacific Northwest Laboratory, specifically addresses the equipment cost estimates used to evaluate the economic impacts of revised standards. A database including commercial equipment list prices and estimated contractor costs was developed, and through statistical modeling, estimated contractor costs are related to equipment parameters including performance. These models are then used to evaluate cost estimates developed by the ASHRAE 90.1 Standing Standards Project Committee, which is in the process of developing a revised ASHRAE 90.1 standard. The database will also be used to support further evaluation of the manufacturer and consumer impacts of standards. Cost estimates developed from the database will serve as inputs to economic modeling tools, which will be used to estimate these impacts. Preliminary results suggest that list pricing is a suitable measure from which to estimate contractor costs for commercial equipment. Models developed from these cost estimates accurately predict estimated costs. The models also confirm the expected relationships between equipment characteristics and cost. Cost models were developed for gas-fired and electric water heaters, gas-fired packaged boilers, and warm air furnaces for indoor installation. Because of industry concerns about the use of the data, information was not available for the other categories of EPAct-covered equipment. These concerns must be addressed to extend the analysis to all EPAct equipment categories.

Freeman, S.L.

1995-01-01T23:59:59.000Z

173

U.S. Commercial Buildings Energy Intensity  

U.S. Energy Information Administration (EIA)

Energy Efficiency > Commercial Buildings Energy Intensities > Table 6a. U.S. Commercial Buildings Energy

174

The following organizations recognize that the Commercial Buildings Energy Consu  

U.S. Energy Information Administration (EIA) Indexed Site

following organizations recognize that the Commercial Buildings Energy Consumption Survey (CBECS) following organizations recognize that the Commercial Buildings Energy Consumption Survey (CBECS) provides critically important information to support programs related to energy efficiency in commercial buildings in the United States. These organizations strongly encourage participation in the 2012 CBECS. A.I.D. Development Group American Council for an Energy-Efficient Economy (ACEEE) American Hotel & Lodging Association American Society of Civil Engineers (ASCE) American Society of Interior Designers (ASID) APPA, "Leadership in Educational Facilities" Architecture 2030 ASHRAE Boston Properties Brandywine Realty Trust Building Owners and Managers Association (BOMA) International CannonDesign Cassidy Turley Center for Environmental Innovation in Roofing

175

Xcel Energy- Commercial and Industrial Standard Offer Program  

Energy.gov (U.S. Department of Energy (DOE))

Xcel Energy Large Commercial and Industrial Standard Offer Program (SOP) pays incentives to businesses for retrofit and new construction projects that save energy in peak summer demand periods and...

176

Building Technologies Office: Commercial Building Partnership Opportunities  

NLE Websites -- All DOE Office Websites (Extended Search)

Partnership Opportunities with the Department of Energy Partnership Opportunities with the Department of Energy Working with industry representatives and partners is critical to achieving significant improvements in the energy efficiency of new and existing commercial buildings. Here you will learn more about the government-industry partnerships that move us toward that goal. Key alliances and partnerships include: Photo of downtown Pittsburgh, Pennsylvania, a municipal Better Buildings Challenge partner, at dusk. Credit: iStockphoto Better Buildings Challenge This national leadership initiative calls on corporate officers, university presidents, and local leaders to progess towards the goal of making American buildings 20 percent more energy-efficient by 2020. Photo of Jim McClendon of Walmart speaking during the CBEA Executive Exchange with Commercial Building Stakeholders forum at the National Renewable Energy Laboratory in Golden, Colorado, on May 24, 2012.

177

Proceedings: Commercial Refrigeration Research Workshop  

Science Conference Proceedings (OSTI)

Improving refrigeration systems for commercial use can enhance both utility load factors and supermarket profits. This workshop has pinpointed research needs in commercial refrigeration and systems integration for a supermarket environment.

1984-10-01T23:59:59.000Z

178

National Grid (Gas) - Commercial Energy Efficiency Rebate Programs (Metro  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Metro New York) Metro New York) National Grid (Gas) - Commercial Energy Efficiency Rebate Programs (Metro New York) < Back Eligibility Commercial Industrial Institutional Multi-Family Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Commercial Weatherization Construction Design & Remodeling Other Manufacturing Appliances & Electronics Water Heating Windows, Doors, & Skylights Maximum Rebate Custom Incentives including Combined Heat and Power: $250,000 Large Industrial Gas Incentives: $250,000 Energy Efficiency Engineering Study: $10,000 Steam Traps: $2,500 All Insulation: $10,000/account Boiler Controls: 2 units ENERGY STAR Programmable Thermostats: 5 units Pipe Insulation: 500 ft Program Info State New York Program Type

179

Energy Storage Systems 2007 Peer Review - Utility & Commercial Applications  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Utility & Commercial Utility & Commercial Applications Presentations Energy Storage Systems 2007 Peer Review - Utility & Commercial Applications Presentations The U.S. DOE Energy Storage Systems Program (ESS) held an annual peer review on September 27, 2007 in San Francisco, CA. Eighteen presentations were divided into categories; those related to utility, commercial, and rail applications of advanced energy storage systems are below. Other presentation categories were: Economics - Benefit Studies and Environment Benefit Studies International Energy Storage Programs Power Electronics Innovations in Energy Storage Systems ESS 2007 Peer Review - Application of Large-Scale ESS in AEP - Ali Nourai, AEP.pdf ESS 2007 Peer Review - Iowa Stored Energy Park - Kent Holst, ISEP.pdf

180

Technology Commercialization Showcase - Home - Energy ...  

Small Business and Clean Energy Alliance (CEA) Partnership; ... The Department Of Energy Technology Commercialization Showcase provides effective ...

Note: This page contains sample records for the topic "large commercial critical" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Information Resources - EERE Commercialization Office  

Information Resources. Here you will find various informational resources related to the commercialization of clean energy technologies. Hawaiian ...

182

Success Stories - EERE Commercialization Office  

Success Stories. As new energy efficient and renewable energy technologies emerge, so do potential business opportunities. These commercialization success stories ...

183

Information Resources - EERE Commercialization Office  

Information Resources. Here you will find various informational resources related to the commercialization of clean energy technologies. Hawaiian Renewable Energy ...

184

Inventor Resources | Technology Commercialization and ...  

Search Technologies; Patents; Contacts. TCP Director Connie Cleary. Tech Commercialization Christine Brakel Cyrena Condemi Kimberley Elcess Poornima ...

185

Nuclear criticality safety guide  

Science Conference Proceedings (OSTI)

This technical reference document cites information related to nuclear criticality safety principles, experience, and practice. The document also provides general guidance for criticality safety personnel and regulators.

Pruvost, N.L.; Paxton, H.C. [eds.] [eds.

1996-09-01T23:59:59.000Z

186

Commercial nuclear power 1990  

Science Conference Proceedings (OSTI)

This report presents the status at the end of 1989 and the outlook for commercial nuclear capacity and generation for all countries in the world with free market economies (FME). The report provides documentation of the US nuclear capacity and generation projections through 2030. The long-term projections of US nuclear capacity and generation are provided to the US Department of Energy's (DOE) Office of Civilian Radioactive Waste Management (OCRWM) for use in estimating nuclear waste fund revenues and to aid in planning the disposal of nuclear waste. These projections also support the Energy Information Administration's annual report, Domestic Uranium Mining and Milling Industry: Viability Assessment, and are provided to the Organization for Economic Cooperation and Development. The foreign nuclear capacity projections are used by the DOE uranium enrichment program in assessing potential markets for future enrichment contracts. The two major sections of this report discuss US and foreign commercial nuclear power. The US section (Chapters 2 and 3) deals with (1) the status of nuclear power as of the end of 1989; (2) projections of nuclear capacity and generation at 5-year intervals from 1990 through 2030; and (3) a discussion of institutional and technical issues that affect nuclear power. The nuclear capacity projections are discussed in terms of two projection periods: the intermediate term through 2010 and the long term through 2030. A No New Orders case is presented for each of the projection periods, as well as Lower Reference and Upper Reference cases. 5 figs., 30 tabs.

Not Available

1990-09-28T23:59:59.000Z

187

Aerocapacitor commercialization plan  

DOE Green Energy (OSTI)

The purpose of the Power-One Aerocapacitor Commercialization Plan is to communicate to members of management and to all employees the overall objectives of the corporation. Power-One, Inc., has participated in a US Federal Government Technology Reinvestment Project (TRP), entitled {open_quotes}Advanced Power Conversion based on the Aerocapacitor{close_quotes}: the project is a group effort, with Lawrence Livermore National Labs, GenCorp/Aerojet, PolyStor Corp. (a start-up company), and Power-One forming the consortium. The expected resulting technology is the {open_quotes}Aerocapacitor{close_quotes}, which possesses much higher performance levels than the usual capacitors on the market today. Power-One hopes to incorporate the Aerocapacitor into some of its products, hence enhancing their performance, as well as market privately-labeled aerocapacitors through its distribution channels. This document describes the details of Power-One`s plan to bring to market and commercialize the Aerocapacitor and Aerocapacitor-based products. This plan was formulated while Power-One was part of the Oerocap project. It has since pulled out of this project. What is presented in this plan is the work which was developed prior to the business decision to terminate this work.

NONE

1995-09-12T23:59:59.000Z

188

New and Underutilized Technology: Commercial Ground Source Heat Pumps |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial Ground Source Heat Commercial Ground Source Heat Pumps New and Underutilized Technology: Commercial Ground Source Heat Pumps October 8, 2013 - 2:59pm Addthis The following information outlines key deployment considerations for commercial ground source heat pumps within the Federal sector. Benefits Commercial ground source heat pumps are ground source heat pump with loops that feed multiple packaged heat pumps and a single ground source water loop. Unit capacity is typically 1-10 tons and may be utilized in an array of multiple units to serve a large load. Application Condensing boilers are appropriate for housing, service, office, and research and development applications. Key Factors for Deployment FEMP has made great progress with commercial ground source heat pump technology deployment within the Federal sector. Primary barriers deal with

189

Entergy Texas - Residential and Small Commercial Standard Offer Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Entergy Texas - Residential and Small Commercial Standard Offer Entergy Texas - Residential and Small Commercial Standard Offer Program Entergy Texas - Residential and Small Commercial Standard Offer Program < Back Eligibility Commercial Construction Low-Income Residential Residential Savings Category Home Weatherization Commercial Weatherization Sealing Your Home Heating & Cooling Commercial Heating & Cooling Cooling Other Ventilation Heat Pumps Appliances & Electronics Water Heating Maximum Rebate Large Projects: 12.5% of total budget; or $237,500 (Residential); $162,500 for Hard-To-Reach A/C and Heat Pump Program: $40,000 Program Info State Texas Program Type Utility Rebate Program Rebate Amount Residential Standard Offer: $250/kW + $0.081/kWh Hard To Reach Standard Offer Program (all measures except CFL): $440/kW +

190

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Commercial Clothes Washers Commercial Clothes Washers Sign up for e-mail updates on regulations for this and other products Manufacturers have been required to comply with the Department of Energy's (DOE) energy conservation standards for commercial clothes washers since 2007. Commercial clothes washers use a water solution of soap, detergent, or both and mechanical movement to clean clothes. Commercial clothes washers are used in commercial settings, multi-family housing, or laundromats. There are two classes of commercial clothes washers: front-loading and top-loading clothes washers. The current standard will save approximately 0.12 quads of energy and result in approximately $1.1 billion in energy bill savings for products shipped from 2007-2036. The standard will avoid about 6.4 million metric tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of 1.3 million automobiles.

191

Commercial Demand Module  

Gasoline and Diesel Fuel Update (EIA)

4 4 The commercial module forecasts consumption by fuel 15 at the Census division level using prices from the NEMS energy supply modules, and macroeconomic variables from the NEMS Macroeconomic Activity Module (MAM), as well as external data sources (technology characterizations, for example). Energy demands are forecast for ten end-use services 16 for eleven building categories 17 in each of the nine Census divisions (see Figure 5). The model begins by developing forecasts of floorspace for the 99 building category and Census division combinations. Next, the ten end-use service demands required for the projected floorspace are developed. The electricity generation and water and space heating supplied by distributed generation and combined heat and power technologies are projected. Technologies are then

192

Commercial Buildings Characteristics 1992  

U.S. Energy Information Administration (EIA) Indexed Site

(92) (92) Distribution Category UC-950 Commercial Buildings Characteristics 1992 April 1994 Energy Information Administration Office of Energy Markets and End Use U.S. Department of Energy Washington, DC 20585 This report was prepared by the Energy Information Administration, the independent statistical and analytical agency within the Department of Energy. The information contained herein should not be construed as advocating or reflecting any policy position of the Department of Energy or any other organization. Contacts The Energy Information Administration (EIA) prepared this publication under the general direction of W. Calvin Kilgore, Director of the Office of Energy Markets and End Use (202-586-1617). The project was directed by Lynda T. Carlson, Director of the Energy End Use and Integrated Statistics Division (EEUISD) (202-586-1112) and Nancy L. Leach, Chief

193

Energy Efficient Commercial Technologies  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial Technologies April 11th, 2012 Presented by: Warren Willits Energy Solutions Center (202) 824-7150 www.ESCenter.org Federal Utility Partnership Working Group Spring 2012 Jekyll Island, GA Todays Energy Efficient Technologies  Water Heating  Heating  Air Conditioning  Humidity Control  CHP / Cogeneration Atmospheric Direct Vent High Efficiency .7 EF Atmospheric water heaters now available 97 % efficient tank water heaters now available Traditional Tank Style Water Heating  Tankless Water Heaters  EF = .82 Standard Unit  EF = .97 Condensing  Solar Water Heaters  With H.E. gas back up systems Newer Water Heaters Water Heater Life Cycle Cost Life Cycle Costs Electric Tank Water Heater Gas Water Heater

194

Nuclear criticality accidents  

SciTech Connect

Criticality occurs when a sufficient quantity of fissionable material is accumulated, and it results in the liberation of nuclear energy. All process accidents have involved plutonium or highly enriched uranium, as have most of the critical experiment accidents. Slightly enriched uranium systems require much larger quantities of material to achieve criticality. An appreciation of criticality accidents should be based on an understanding of factors that influence criticality, which are discussed in this article. 11 references.

Smith, D.R. (Los Alamos National Laboratory, New Mexico (Unites States))

1991-10-01T23:59:59.000Z

195

Xcel Energy (Electric) - Commercial Energy Efficiency Rebate...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial Energy Efficiency Rebate Program (New Mexico) Xcel Energy (Electric) - Commercial Energy Efficiency Rebate Program (New Mexico) Eligibility Commercial Industrial Savings...

196

Commercial Motor Vehicle Brake-Related Research  

E-Print Network (OSTI)

Commercial Motor Vehicle Brake-Related Research Commercial Motor Vehicle Roadside Technology Corridor Safety Technology Showcase October 14, 2010 Commercial Motor Vehicle Roadside Technology Corridor

197

Assessment of utilization and downtime of a commercial level multi-pass corn stover harvesting systems.  

E-Print Network (OSTI)

??With commercial scale cellulosic ethanol in the formative stages of building large-scale feedstock supply chains there is a requirement for biomass harvesting equipment to be (more)

Covington, Benjamin Ross

2013-01-01T23:59:59.000Z

198

Advanced Controls and Communications for Demand Response and Energy Efficiency in Commercial Buildings  

E-Print Network (OSTI)

for a large portion of summer peak demand. Research resultspotential to reduce peak demand in commercial buildingsbuildings contribution to peak demand and the use of energy

Kiliccote, Sila; Piette, Mary Ann; Hansen, David

2006-01-01T23:59:59.000Z

199

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Commercial and Industrial Pumps Energy Conservation Standards Commercial and Industrial Pumps Energy Conservation Standards Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) is considering developing test procedures, labels, and energy conservation standards for commercial and industrial pumps. Pumps exist in numerous applications, including agriculture, oil and gas production, water and wastewater, manufacturing, mining, and commercial building systems. There are currently no federal standards or test procedures for commercial and industrial pumps. Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a notice of public meeting and availability of the framework document regarding commercial and industrial pumps. 78 FR 7304 (February 1, 2013).

200

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Commercial Warm Air Furnaces Commercial Warm Air Furnaces Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of commercial warm air furnaces since 1994. Commercial warm air furnaces are self-contained oil-fired or gas-fired furnaces that are designed to supply heated air through ducts to spaces that require it. Commercial warm air furnaces are industrial equipment and have a maximum rated input capacity of 225,000 British thermal units (Btu) an hour or more. Recent Updates | Standards | Test Procedures | Waiver, Exception, and Exemption Information | Statutory Authority | Historical Information | Contact Information Recent Updates DOE published a request for information regarding energy conservation standards for commercial warm air furnaces. 78 FR 25627 (May 2, 2013). For more information, please see the rulemaking webpage.

Note: This page contains sample records for the topic "large commercial critical" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Residential Commercial Industrial Year  

Gasoline and Diesel Fuel Update (EIA)

4 4 Residential Commercial Industrial Year and State Volume (million cubic feet) Consumers Volume (million cubic feet) Consumers Volume (million cubic feet) Consumers 2000 Total ................... 4,996,179 59,252,728 3,182,469 5,010,817 8,142,240 220,251 2001 Total ................... 4,771,340 60,286,364 3,022,712 4,996,446 7,344,219 217,026 2002 Total ................... 4,888,816 61,107,254 3,144,169 5,064,384 7,507,180 205,915 2003 Total ................... R 5,079,351 R 61,871,450 R 3,179,493 R 5,152,177 R 7,150,396 R 205,514 2004 Total ................... 4,884,521 62,469,142 3,141,653 5,135,985 7,250,634 212,191 Alabama ...................... 43,842 806,175 26,418 65,040 169,135 2,800 Alaska.......................... 18,200 104,360 18,373 13,999 46,580 10 Arizona ........................

202

CRITICALITY SAFETY (CS)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

OBJECTIVE CS.1 The LANL criticality safety program provides the required technical guidance and oversight capabilities to ensure a comprehensive criticality safety program for the storage of nuclear materials in SSTs. (Core Requirements 3, 4, 8) Criteria * The Criticality Safety Program is an administrative TSR and meets the General and * Specific Requirements of DOE O 420.1A, Section 4.3 Nuclear Criticality Safety. * All processes and operations involving significant quantities of fissile materials are * described in current procedures approved by line management. * Procedures contain approved criticality controls and limits, based on HSR-6 evaluations and recommendations. * Supervisors, operations personnel, and criticality safety officers have received

203

Performance of Commercial Radiometers in Very Low Temperature and Pressure Environments Typical of Polar Regions and of the Stratosphere: A Laboratory Study  

Science Conference Proceedings (OSTI)

Characterizing the performance of ground-based commercial radiometers in cold and/or low-pressure environments is critical for developing accurate flux measurements in the polar regions and in the upper troposphere and stratosphere. Commercially ...

Wenying Su; Ellsworth Dutton; Thomas P. Charlock; Warren Wiscombe

2008-04-01T23:59:59.000Z

204

Commercial Weatherization | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial Weatherization Commercial Weatherization Commercial Weatherization When high energy bills and a dwindling customer base threatened the Athenian Corner's well-being, the restaurant turned to energy efficiency upgrades to help operating costs and improve its bottom line. Learn how energy efficiency upgrades are helping the Athenian Corner be a viable business. When high energy bills and a dwindling customer base threatened the Athenian Corner's well-being, the restaurant turned to energy efficiency upgrades to help operating costs and improve its bottom line. Learn how energy efficiency upgrades are helping the Athenian Corner be a viable business. Commercial buildings consume 19 percent of the energy used in the U.S.

205

Commercial Lighting | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lighting Lighting Commercial Lighting At an estimated cost of $38 billion a year, lighting represents the largest source of electricity consumption in U.S. commercial buildings. By combining an inexpensive camera with a high-speed microprocessor and algorithms, researchers at the National Renewable Energy Lab developed an occupancy sensor can recognize the presence of human occupants more than 90 percent of the time -- an advancement that could lead to enormous energy savings in commercial buildings. At an estimated cost of $38 billion a year, lighting represents the largest source of electricity consumption in U.S. commercial buildings. By combining an inexpensive camera with a high-speed microprocessor and

206

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

updates on regulations for this and other products There are currently no energy conservation standards for commercial and industrial fans and blowers. Fans and blowers are...

207

Technology Commercialization Fund - Home - Energy ...  

How the Technology Commercialization Fund Works. When awarded, fund dollars must be spent on prototype advancement and cannot be used for scientific ...

208

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

subpart W. Statutory Authority The current energy conservation standards for commercial refrigeration equipment are mandated by Part A-1, the "Certain Industrial Equipment" of...

209

OpenEI - commercial building  

Open Energy Info (EERE)

http:en.openei.orgdatasetstaxonomyterm4040 en Commercial Reference Building: Quick Service Restaurant http:en.openei.orgdatasetsnode441

210

National Laboratories - EERE Commercialization Office  

National Laboratories. The U.S. Department of Energy's (DOE) national laboratories play an important role in the development and commercialization of ...

211

Commercial Wind Energy Property Valuation  

Energy.gov (U.S. Department of Energy (DOE))

Prior to 2007, wind energy devices generating electricity for commercial sale were assessed differently depending on where they were located. Some counties valued the entire turbine structure ...

212

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Certification of Commercial Heating, Ventilating, Air-Conditioning, Refrigeration, and Water Heating Equipment Sign up for e-mail updates on regulations for this and other products...

213

Available Technologies: Superinsulated Commercial Window ...  

Superinsulated Commercial Window Framing System. IB-3155. APPLICATIONS OF TECHNOLOGY: Window and faade framing systems for non-residential building c ...

214

SF 6432-CI Commercial Items  

NLE Websites -- All DOE Office Websites (Extended Search)

or alcoholic beverages while on the premises; Control : SF 6432-CI Title: Standard Terms and Conditions for Commercial Items Owner: Procurement Policy & Quality Dept Release...

215

National Laboratories - EERE Commercialization Office  

National Laboratories. The U.S. Department of Energy's (DOE) national laboratories play an important role in the development and commercialization of new energy ...

216

Contacts - EERE Commercialization Office - Energy  

Commercialization Contacts. Here you'll find contact information for any questions or comments you may have about the Office of Energy Efficiency and Renewable Energy ...

217

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Amendments and Correction to Petitions for Waiver and Interim Waiver for Consumer Products and Commercial and Industrial Equipment Sign up for e-mail updates on regulations for...

218

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Commercial Warm Air Furnaces Standard Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) is considering amending energy...

219

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Information Collection on Commercial Equipment Labeling Sign up for e-mail updates on regulations for this and other products The Department of Energy is seeking information...

220

Technology Commercialization & Partnerships | BNL  

NLE Websites -- All DOE Office Websites (Extended Search)

Technology Commercialization & Partnerships Technology Commercialization & Partnerships Home For BNL Inventors For Industry For Entrepreneurs Sponsored Research Search Technologies Patents Contacts TCP Director Connie Cleary Tech Commercialization Christine Brakel Cyrena Condemi Kimberley Elcess Poornima Upadhya Partnerships Mike Furey, Manager Ginny Coccorese Alison Schwarz Intellectual Property Legal Group (Legal Dept.) Dorene Price, Chief Intellectual Property Counsel Lars Husebo, Attorney Maria Pacella, Sr. Staff Specialist William Russell, Asst. Staff Specialist INNOVATION MEETS BUSINESS at Brookhaven National Laboratory. WE GRANT LICENSES for our intellectual property to existing and start up companies. WE SEEK FUNDING from experienced investors to develop our intellectual assets. Tech Commercialization News

Note: This page contains sample records for the topic "large commercial critical" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

NREL: Technology Transfer - Commercialization Programs  

NLE Websites -- All DOE Office Websites (Extended Search)

Commercialization Programs Commercialization Programs Through our commercialization programs, we help accelerate the transfer of renewable energy and energy efficiency technologies into the marketplace. Clean Energy Alliance The Clean Energy Alliance is an alliance of the nation's top business incubators that provide business services to nascent clean energy entrepreneurs. NREL partners with these elite business incubators to help foster the growth of robust clean energy businesses and commercialize their technologies. Colorado Center for Renewable Energy Economic Development Formerly the Colorado Cleantech Initiative program, the Colorado Center for Renewable Energy Economic Development (CREED) is a joint effort between NREL, the State of Colorado, and affiliated stakeholders to provide

222

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

for small electric motors beginning 2015. A small commercial or industrial electric motor converts electrical energy to rotating mechanical energy. When operating, the...

223

ORNL partners on critical materials hub | ornl.gov  

NLE Websites -- All DOE Office Websites (Extended Search)

ORNL partners on critical materials hub ORNL partners on critical materials hub January 01, 2013 The Critical Materials Institute builds on the Department of Energy's Critical Materials Strategy report, which addresses the use of rare earths and other critical materials in clean energy components, products, and processes. December 2011. Credit: U.S. DOE. ORNL wins big as part of a team led by Ames Labora-tory, which was selected for an Energy Innovation Hub to address shortages of critical materials, including rare earth metals. The award of up to $120 million over five years for the Critical Materials Institute involves four national labs, academia, and industrial partners. ORNL will play a key role in conducting the CMI's mis-sion to eliminate materials criticality as an impediment to the commercialization of clean

224

Commercial Motor Vehicle Brake Assessment Tools  

E-Print Network (OSTI)

Commercial Motor Vehicle Brake Assessment Tools Commercial Motor Vehicle Roadside Technology Corridor Safety Technology Showcase October 14, 2010 Commercial Motor Vehicle Roadside Technology Corridor #12;Overview · Commercial Motor Vehicle (CMV) Air Brake System · North American Standard Level-1

225

An Approach for Validating Actinide and Fission Product Burnup Credit Criticality Safety Analyses--Criticality (keff) Predictions  

SciTech Connect

One of the most significant remaining challenges associated with expanded implementation of burnup credit in the United States is the validation of depletion and criticality calculations used in the safety evaluation - in particular, the availability and use of applicable measured data to support validation, especially for fission products. Applicants and regulatory reviewers have been constrained by both a scarcity of data and a lack of clear technical basis or approach for use of the data. U.S. Nuclear Regulatory Commission (NRC) staff have noted that the rationale for restricting their Interim Staff Guidance on burnup credit (ISG-8) to actinide-only is based largely on the lack of clear, definitive experiments that can be used to estimate the bias and uncertainty for computational analyses associated with using burnup credit. To address the issue of validation, the NRC initiated a project with the Oak Ridge National Laboratory to (1) develop and establish a technically sound validation approach (both depletion and criticality) for commercial spent nuclear fuel (SNF) criticality safety evaluations based on best-available data and methods and (2) apply the approach for representative SNF storage and transport configurations/conditions to demonstrate its usage and applicability, as well as to provide reference bias results. The purpose of this paper is to describe the criticality (k{sub eff}) validation approach, and resulting observations and recommendations. Validation of the isotopic composition (depletion) calculations is addressed in a companion paper at this conference. For criticality validation, the approach is to utilize (1) available laboratory critical experiment (LCE) data from the International Handbook of Evaluated Criticality Safety Benchmark Experiments and the French Haut Taux de Combustion (HTC) program to support validation of the principal actinides and (2) calculated sensitivities, nuclear data uncertainties, and the limited available fission product LCE data to predict and verify individual biases for relevant minor actinides and fission products. This paper (1) provides a detailed description of the approach and its technical bases, (2) describes the application of the approach for representative pressurized water reactor and boiling water reactor safety analysis models to demonstrate its usage and applicability, (3) provides reference bias results based on the prerelease SCALE 6.1 code package and ENDF/B-VII nuclear cross-section data, and (4) provides recommendations for application of the results and methods to other code and data packages.

Scaglione, John M [ORNL; Mueller, Don [ORNL; Wagner, John C [ORNL

2011-01-01T23:59:59.000Z

226

Probaability of Criticality for MOX SNF  

Science Conference Proceedings (OSTI)

The purpose of this calculation is to provide a conservative (upper bound) estimate of the probability of criticality for mixed oxide (MOX) spent nuclear fuel (SNF) of the Westinghouse pressurized water reactor (PWR) design that has been proposed for use. with the Plutonium Disposition Program (Ref. 1, p. 2). This calculation uses a Monte Carlo technique similar to that used for ordinary commercial SNF (Ref. 2, Sections 2 and 5.2). Several scenarios, covering a range of parameters, are evaluated for criticality. Parameters specifying the loss of fission products and iron oxide from the waste package are particularly important. This calculation is associated with disposal of MOX SNF.

P. Gottlieb

1999-09-28T23:59:59.000Z

227

3129 Commercial Analysis 20130205 LBNL - Home - Energy ...  

Commercialization-Analysis-&Roadmap-- ... theenergycontentofthegasand ... commercialized, it must meet a market demanda demand ...

228

Northern Municipal Power Agency - Commercial Energy Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

- Commercial Energy Efficiency Rebate Program (Minnesota) < Back Eligibility Commercial Industrial Institutional Local Government Nonprofit State Government Savings Category...

229

Cedarburg Light & Water Utility - Commercial Energy Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Efficiency Rebate Program Cedarburg Light & Water Utility - Commercial Energy Efficiency Rebate Program Eligibility Agricultural Commercial Fed. Government Industrial Local...

230

Longmont Power & Communications - Commercial and Industrial Energy...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

are here Home Savings Longmont Power & Communications - Commercial and Industrial Energy Efficiency Rebate Program Longmont Power & Communications - Commercial and...

231

Burlington Electric Department - Commercial Energy Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Agencies You are here Home Savings Burlington Electric Department - Commercial Energy Efficiency Rebate Program Burlington Electric Department - Commercial Energy...

232

NREL: Technology Transfer - Commercialization Assistance Program  

National Renewable Energy Laboratory Technology Transfer Commercialization Assistance Program. The NREL Commercialization Assistance Program (NCAP) helps emerging ...

233

NREL: Technology Transfer - Agreements for Commercializing ...  

National Renewable Energy Laboratory Technology Transfer Agreements for Commercializing Technology. NREL uses Agreements for Commercializing Technology (ACT) when a ...

234

Redding Electric - Residential and Commercial Energy Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Savings For Home Weatherization Commercial Weatherization Sealing Your Home Heating & Cooling Commercial Heating & Cooling Cooling Other Ventilation Manufacturing Heat Pumps...

235

Building Technologies Office: Commercial Building Energy Asset...  

NLE Websites -- All DOE Office Websites (Extended Search)

TECHNOLOGIES RESIDENTIAL BUILDINGS COMMERCIAL BUILDINGS APPLIANCE & EQUIPMENT STANDARDS BUILDING ENERGY CODES EERE Building Technologies Office Commercial Buildings...

236

Events - EERE Commercialization Office - Home - Energy ...  

Bookmark Events - EERE Commercialization Office on Google; Bookmark Events - EERE Commercialization Office on Delicious; Rank Events - EERE ...

237

Building Technologies Office: Commercial Building Activities  

NLE Websites -- All DOE Office Websites (Extended Search)

on Twitter Bookmark Building Technologies Office: Commercial Building Activities on Google Bookmark Building Technologies Office: Commercial Building Activities on Delicious...

238

Avista Utilities (Electric) - Commercial Energy Efficiency Incentives...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Efficiency Incentives Program Avista Utilities (Electric) - Commercial Energy Efficiency Incentives Program Eligibility Commercial Industrial InstallerContractor Savings...

239

EIA Energy Kids - In Commercial Buildings  

U.S. Energy Information Administration (EIA)

Using & Saving Energy In Commercial Buildings. How do commercial buildings like offices, hospitals, schools, places of worship, warehouses, hotels, ...

240

Commercialization of fuel-cells  

DOE Green Energy (OSTI)

This report is an abbreviated version of the ''Report of the DOE Advanced Fuel Cell Commercialization Working Group (AFC2WG),'' released January 1995. We describe fuel-cell commercialization for stationary power applications of phosphoric acid, molten carbonate, solid oxide, and polymer electrolyte membrane fuel cells.

Penner, S.S.; Appleby, A.J.; Baker, B.S.; Bates, J.L.; Buss, L.B.; Dollard, W.J.; Farris, P.J.; Gillis, E.A.; Gunsher, J.A.; Khandkar, A.; Krumpelt, M.; O'Sullivan, J.B.; Runte, G.; Savinell, R.F.; Selman, J.R.; Shores, D.A.; Tarman, P.

1995-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "large commercial critical" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Commercial Development Business Development 7  

E-Print Network (OSTI)

Office of Technology Commercialization www.techtransfer.umd.edu #12;OVERVIEWOVERVIEW · Opening remarks www.techtransfer.umd.edu #12;Types of Intellectual Property: PatentsTypes of Intellectual Property of Technology Commercialization www.techtransfer.umd.edu #12;Types of Intellectual Property: Copyright

Davies, Christopher

242

Uranium Metal: Potential for Discovering Commercial Uses  

NLE Websites -- All DOE Office Websites (Extended Search)

Uranium Metal Uranium Metal Potential for Discovering Commercial Uses Steven M. Baker, Ph.D. Knoxville Tn 5 August 1998 Summary Uranium Metal is a Valuable Resource 3 Large Inventory of "Depleted Uranium" 3 Need Commercial Uses for Inventory  Avoid Disposal Cost  Real Added Value to Society 3 Uranium Metal Has Valuable Properties  Density  Strength 3 Market will Come if Story is Told Background The Nature of Uranium Background 3 Natural Uranium: 99.3% U238; 0.7% U 235 3 U235 Fissile  Nuclear Weapons  Nuclear Reactors 3 U238 Fertile  Neutron Irradiation of U238 Produces Pu239  Neutrons Come From U235 Fission  Pu239 is Fissile (Weapons, Reactors, etc.) Post World War II Legacy Background 3 "Enriched" Uranium Product  Weapons Program 

243

PSNH- Large Business Energy Efficiency Retrofit Rebate Program  

Energy.gov (U.S. Department of Energy (DOE))

Public Service of New Hampshire (PSNH), in collaboration with [http://www.nhsaves.com/ nhsaves], encourages large commercial and industrial customers in existing facilities to conserve energy...

244

CRITICALITY SAFETY (CS)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Objective CS.1 - A criticality safety program is established, sufficient numbers of qualified personnel are provided, and adequate facilities and equipment are available to ensure criticality safety support services are adequate for safe operations. (Core Requirements 1, 2, and 6) Criteria * Functions, assignments, responsibilities, and reporting relationships are clearly defined, understood, and effectively implemented. * Operations support personnel for the criticality safety area are adequately staffed and trained. Approach Record Review: Review the documentation that establishes the Criticality Safety Requirements (CSRs) for appropriateness and completeness. Review for adequacy and completion the criticality safety personnel training records that indicate training on facility procedures and systems under

245

Nuclear criticality safety  

SciTech Connect

Important facts of the nuclear criticality safety field are covered in this volume. Both theoretical and practical aspects of the subject are included, based on insights provided by criticality experts and published information from many sources. An overview of nuclear criticality safety theory and a variety of practical in-plant operation applications are presented. Underlying principles of nuclear criticality safety are introduced and the state of the art of this technical discipline is reviewed. Criticality safety theoretical concepts, accident experience, standards, experiments computer calculations, integration of safety methods into individual practices, and overall facility operations are all included.

Knief, R.A.

1985-01-01T23:59:59.000Z

246

Commercial Building Partnership Opportunities with the Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Building Partnership Opportunities with the Department Building Partnership Opportunities with the Department of Energy Commercial Building Partnership Opportunities with the Department of Energy Working with industry representatives and partners is critical to achieving significant improvements in the energy efficiency of new and existing commercial buildings. Here you will learn more about the government-industry partnerships that move us toward that goal. Key alliances and partnerships include: Better Buildings Challenge Photo of downtown Pittsburgh, Pennsylvania, a municipal Better Buildings Challenge partner, at dusk. This national leadership initiative calls on corporate officers, university presidents, and local leaders to progess towards the goal of making American buildings 20 percent more energy-efficient by 2020.

247

DOE Commercial Reference Buildings  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Buildings Buildings Version 1.4_7.0 New Construction, ANSI/ASHRAE/IESNA 90.1-2004 Site Energy Use Intensities (EUIs) [kBtu/ft 2 /yr] August 2012 Miami Houston Phoenix Atlanta Los Angeles Las Vegas San Francisco Baltimore Albuquerque Seattle Chicago Denver Minneapolis Helena Duluth Fairbanks Weighted Average Climate Zone 1A 2A 2B 3A 3B 3B 3C 4A 4B 4C 5A 5B 6A 6B 7 8 Large Office 47 48 45 44 39 41 41 46 40 41 47 42 52 46 53 67 45 Medium Office 51 51 51 48 41 47 43 51 46 45 52 47 57 51 59 76 50 Small Office 52 51 53 47 41 46 41 51 47 47 54 49 59 54 61 83 51 Warehouse 29 23 24 27 19 24 23 32 29 28 38 34 46 41 53 78 30 Stand-alone Retail 60 63 62 63 46 58 53 74 64 68 84 72 96 87 107 150 72 Strip Mall 57 61 60 65 48 61 57 78 68 74 89 76 103 94 115 164 71 Primary School 57 57 57 55 46 54 52 62 56 55 66 59 75 67 80 103 60 Secondary School 60 61 59 60 44 56 51 71 59 63 78 66 91 79 99 135 67 Supermarket

248

Status, plans, and capabilities of the Nuclear Criticality Information System  

SciTech Connect

The Nuclear Criticality Information System (NCIS), in preparation since 1981, has substantially evolved and now contains a growing number of resources pertinent to nuclear criticality safety. These resources include bibliographic compilations, experimental data, communications media, and the International Directory of Nuclear Criticality Safety Personnel. These resources are part of the LLNL Technology Information System (TIS) which provides the host computer for NCIS. The TIS provides nationwide access to authorized members of the nuclear criticality community via interactive dial-up from computer terminals that utilize communication facilities such as commercial and federal telephone networks, toll-free WATS lines, TYMNET, and the ARPANET/MILNET computer network.

Koponen, B.L.

1984-01-06T23:59:59.000Z

249

High-performance commercial building systems  

SciTech Connect

This report summarizes key technical accomplishments resulting from the three year PIER-funded R&D program, ''High Performance Commercial Building Systems'' (HPCBS). The program targets the commercial building sector in California, an end-use sector that accounts for about one-third of all California electricity consumption and an even larger fraction of peak demand, at a cost of over $10B/year. Commercial buildings also have a major impact on occupant health, comfort and productivity. Building design and operations practices that influence energy use are deeply engrained in a fragmented, risk-averse industry that is slow to change. Although California's aggressive standards efforts have resulted in new buildings designed to use less energy than those constructed 20 years ago, the actual savings realized are still well below technical and economic potentials. The broad goal of this program is to develop and deploy a set of energy-saving technologies, strategies, and techniques, and improve processes for designing, commissioning, and operating commercial buildings, while improving health, comfort, and performance of occupants, all in a manner consistent with sound economic investment practices. Results are to be broadly applicable to the commercial sector for different building sizes and types, e.g. offices and schools, for different classes of ownership, both public and private, and for owner-occupied as well as speculative buildings. The program aims to facilitate significant electricity use savings in the California commercial sector by 2015, while assuring that these savings are affordable and promote high quality indoor environments. The five linked technical program elements contain 14 projects with 41 distinct R&D tasks. Collectively they form a comprehensive Research, Development, and Demonstration (RD&D) program with the potential to capture large savings in the commercial building sector, providing significant economic benefits to building owners and health and performance benefits to occupants. At the same time this program can strengthen the growing energy efficiency industry in California by providing new jobs and growth opportunities for companies providing the technology, systems, software, design, and building services to the commercial sector. The broad objectives across all five program elements were: (1) To develop and deploy an integrated set of tools and techniques to support the design and operation of energy-efficient commercial buildings; (2) To develop open software specifications for a building data model that will support the interoperability of these tools throughout the building life-cycle; (3) To create new technology options (hardware and controls) for substantially reducing controllable lighting, envelope, and cooling loads in buildings; (4) To create and implement a new generation of diagnostic techniques so that commissioning and efficient building operations can be accomplished reliably and cost effectively and provide sustained energy savings; (5) To enhance the health, comfort and performance of building occupants. (6) To provide the information technology infrastructure for owners to minimize their energy costs and manage their energy information in a manner that creates added value for their buildings as the commercial sector transitions to an era of deregulated utility markets, distributed generation, and changing business practices. Our ultimate goal is for our R&D effort to have measurable market impact. This requires that the research tasks be carried out with a variety of connections to key market actors or trends so that they are recognized as relevant and useful and can be adopted by expected users. While some of this activity is directly integrated into our research tasks, the handoff from ''market-connected R&D'' to ''field deployment'' is still an art as well as a science and in many areas requires resources and a timeframe well beyond the scope of this PIER research program. The TAGs, PAC

Selkowitz, Stephen

2003-10-01T23:59:59.000Z

250

High-performance commercial building systems  

SciTech Connect

This report summarizes key technical accomplishments resulting from the three year PIER-funded R&D program, ''High Performance Commercial Building Systems'' (HPCBS). The program targets the commercial building sector in California, an end-use sector that accounts for about one-third of all California electricity consumption and an even larger fraction of peak demand, at a cost of over $10B/year. Commercial buildings also have a major impact on occupant health, comfort and productivity. Building design and operations practices that influence energy use are deeply engrained in a fragmented, risk-averse industry that is slow to change. Although California's aggressive standards efforts have resulted in new buildings designed to use less energy than those constructed 20 years ago, the actual savings realized are still well below technical and economic potentials. The broad goal of this program is to develop and deploy a set of energy-saving technologies, strategies, and techniques, and improve processes for designing, commissioning, and operating commercial buildings, while improving health, comfort, and performance of occupants, all in a manner consistent with sound economic investment practices. Results are to be broadly applicable to the commercial sector for different building sizes and types, e.g. offices and schools, for different classes of ownership, both public and private, and for owner-occupied as well as speculative buildings. The program aims to facilitate significant electricity use savings in the California commercial sector by 2015, while assuring that these savings are affordable and promote high quality indoor environments. The five linked technical program elements contain 14 projects with 41 distinct R&D tasks. Collectively they form a comprehensive Research, Development, and Demonstration (RD&D) program with the potential to capture large savings in the commercial building sector, providing significant economic benefits to building owners and health and performance benefits to occupants. At the same time this program can strengthen the growing energy efficiency industry in California by providing new jobs and growth opportunities for companies providing the technology, systems, software, design, and building services to the commercial sector. The broad objectives across all five program elements were: (1) To develop and deploy an integrated set of tools and techniques to support the design and operation of energy-efficient commercial buildings; (2) To develop open software specifications for a building data model that will support the interoperability of these tools throughout the building life-cycle; (3) To create new technology options (hardware and controls) for substantially reducing controllable lighting, envelope, and cooling loads in buildings; (4) To create and implement a new generation of diagnostic techniques so that commissioning and efficient building operations can be accomplished reliably and cost effectively and provide sustained energy savings; (5) To enhance the health, comfort and performance of building occupants. (6) To provide the information technology infrastructure for owners to minimize their energy costs and manage their energy information in a manner that creates added value for their buildings as the commercial sector transitions to an era of deregulated utility markets, distributed generation, and changing business practices. Our ultimate goal is for our R&D effort to have measurable market impact. This requires that the research tasks be carried out with a variety of connections to key market actors or trends so that they are recognized as relevant and useful and can be adopted by expected users. While some of this activity is directly integrated into our research tasks, the handoff from ''market-connected R&D'' to ''field deployment'' is still an art as well as a science and in many areas requires resources and a timeframe well beyond the scope of this PIER research program. The TAGs, PAC and other industry partners have assisted directly in this effort

Selkowitz, Stephen

2003-10-01T23:59:59.000Z

251

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Commercial Clothes Washers Energy Conservation Standard Commercial Clothes Washers Energy Conservation Standard Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) is considering whether to revise its energy conservation standards for commercial clothes washers. This current rulemaking will satisfy the requirement to publish the second final rule by January 1, 2015 as mandated by the Energy Policy and Conservation Act (EPCA). Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates The DOE published a notice of public meeting and availability of the framework document for commercial clothes washers. 77 FR 48108 (August 13, 2012). Public Meeting Information

252

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

heaters, gas-fired and oil-fired instantaneous water heaters and hot water supply boilers, and unfired hot water storage tanks. Commercial water heating equipment is used to...

253

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Commercial Packaged Boilers Determination Sign up for e-mail updates on regulations for this and other products The U.S. Department of Energy (DOE) has initiated this rulemaking to...

254

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Commercial Packaged Boilers Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of...

255

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Automatic Commercial Ice Makers Energy Conservation Standard Sign up for e-mail updates on regulations for this and other products The purpose of this rulemaking is to: 1)...

256

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Part A-1 of Title III (42 U.S.C. 6311-6317) establishes a similar program for ''Certain Industrial Equipment,'' which includes commercial refrigeration equipment. Amendments to...

257

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

for automatic commercial ice-making equipment cover maximum energy use and maximum condenser water use of cube ice machines with harvest rates between 50 and 2,500 lbs of ice...

258

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

and heat pumps are air-cooled, water-cooled, evaporatively-cooled, or water source unitary air conditioners or heat pumps that are used for space conditioning of commercial...

259

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

and Industrial Fans and Blowers Sign up for e-mail updates on regulations for this and other products There are no federal standards or test procedures for commercial and...

260

Tax Deductions for Commercial Buildings  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tax Deductions for Commercial Buildings Tax Deductions for Commercial Buildings Promoting Energy Savings for Businesses S igned by President Bush on August 8, 2005, the Energy Policy Act (EPACT) lays the foundation for the new Federal tax incentives for consumers and businesses that pursue energy efficiency and the use of renewable energy. For updated information about the tax incentives, see www.energy.gov. This web- site also describes other EPACT provisions of interest to businesses, including incen- tives for distributed generation and hybrid fuel fleet vehicles. Tax Deductions for Commercial Building Owners Commercial building owners and lessees who purchase and install energy-saving products in their businesses can qualify for a tax deduction under EPACT. Buildings must achieve a 50 percent reduction in

Note: This page contains sample records for the topic "large commercial critical" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Commercial and Industrial Pumps Commercial and Industrial Pumps Sign up for e-mail updates on regulations for this and other products Pumps are used in agriculture, oil and gas production, water and wastewater, manufacturing, mining, and commercial building systems. Currently there are no energy conservation standards for pumps. The Department of Energy (DOE) will conduct an analysis of the energy use, emissions, costs, and benefits associated with this equipment during the commercial and industrial pumps energy conservation standards rulemaking. Recent Updates | Standards | Test Procedures | Waiver, Exception, and Exemption Information | Statutory Authority | Historical Information | Contact Information Recent Updates DOE published a notice of public meeting and availability of the framework document. 78 FR 7304 (Feb. 1, 2013). For more information, please see the rulemaking page.

262

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Commercial and Industrial Compressors Determination Commercial and Industrial Compressors Determination Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) proposes to determine that commercial and industrial compressors meet the criteria for covered equipment under Part A-1 of Title III of the Energy Policy and Conservation Act (EPCA), as amended. Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a Proposed Coverage Determination concerning commercial and industrial compressors. 77 FR 76972 (Dec. 31, 2012). Public Meeting Information No public meeting is scheduled at this time. Submitting Public Comments The comment period is closed.

263

Intitutional constraints to fusion commercialization  

SciTech Connect

The major thrust of this report is that the long time frame associated with the development of commercial fusion systems in the context of the commercialization and institutional history of an allied technology, fission-power, suggests that fusion commercialization will not occur without active and broad-based support on the part of the Nation's political leaders. Its key recommendation is that DOE fusion planners devote considerable resources to analytical efforts aimed at determining the need for fusion and the timing of that need, in order to convince policymakers that they need do more than preserve fusion as an option for application at some indefinite point in the future. It is the thesis of the report that, in fact, an act of political vision on the part of the Nation's leaders will be required to accomplish fusion commercialization.

1979-10-01T23:59:59.000Z

264

Reference handbook: Nuclear criticality  

SciTech Connect

The purpose for this handbook is to provide Rocky Flats personnel with the information necessary to understand the basic principles underlying a nuclear criticality.

1991-12-06T23:59:59.000Z

265

Properties of Neutron Star Critical Collapses  

E-Print Network (OSTI)

Critical phenomena in gravitational collapse opened a new mathematical vista into the theory of general relativity and may ultimately entail fundamental physical implication in observations. However, at present, the dynamics of critical phenomena in gravitational collapse scenarios are still largely unknown. My thesis seeks to understand the properties of the threshold in the solution space of the Einstein field equations between the black hole and neutron star phases, understand the properties of the neutron star critical solution and clarify the implication of these results on realistic astrophysical scenarios. We develop a new set of neutron star-like initial data to establish the universality of the neutron star critical solution and analyze the structure of neutron star and neutron star-like critical collapses via the study of the phase spaces. We also study the different time scales involved in the neutron star critical solution and analyze the properties of the critical index via comparisons between neutron star and neutron star-like initial data. Finally, we explore the boundary of the attraction basin of the neutron star critical solution and its transition to a known set of non-critical fixed points.

Mew-Bing Wan

2010-01-10T23:59:59.000Z

266

National Fuel - Large Non-Residential Conservation Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

National Fuel - Large Non-Residential Conservation Program National Fuel - Large Non-Residential Conservation Program National Fuel - Large Non-Residential Conservation Program < Back Eligibility Commercial Industrial Institutional Local Government Nonprofit Schools Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Construction Commercial Weatherization Design & Remodeling Other Manufacturing Appliances & Electronics Water Heating Maximum Rebate Commercial Custom Rebates: $200,000 Industrial Custom Rebates: $5,000,000 Program Info State New York Program Type Utility Rebate Program Rebate Amount Custom Rebates: $15/Mcf x the gas savings or 50% of the total project cost Unit Heater: $1000 Hot Air Furnace: $500 Low Intensity Infrared Heating: $500 Programmable Thermostat: $25

267

BetterBuildings Financing Energy Efficiency Retrofits in the Commercial Sector - Part 1  

NLE Websites -- All DOE Office Websites (Extended Search)

Small Commercial Energy Efficiency Finance Programs Small Commercial Energy Efficiency Finance Programs Sponsored by State Governments SURVEY OF SURVEY OF SMALL COMMERCIAL ENERGY EFFICIENCY FINANCE PROGRAMS SPONSORED BY PROGRAMS SPONSORED BY STATE GOVERNMENTS May 3, 2011 Background of Small Commercial Finance Program Survey  Includes 20 States ( (mostly y identified from database of state incentives for renewable energy, DSIRE)  Sponsoring programs for:  small commercial (generally defined as 30,000 square feet or less and/or 150 kW or less) or   both small and large commercial sectors both small and large commercial sectors  Discussions with program managers   Creation of a table of program elements Creation of a table of program elements

268

Defending Critical Infrastructure  

Science Conference Proceedings (OSTI)

We apply new bilevel and trilevel optimization models to make critical infrastructure more resilient against terrorist attacks. Each model features an intelligent attacker (terrorists) and a defender (us), information transparency, and sequential actions ... Keywords: bilevel program, critical infrastructure protection, homeland defense, homeland security, mixed-integer program, trilevel program

Gerald Brown; Matthew Carlyle; Javier Salmern; Kevin Wood

2006-11-01T23:59:59.000Z

269

Commercial Motor Vehicle Roadside Technology Corridor (CMVRTC)  

E-Print Network (OSTI)

Commercial Motor Vehicle Roadside Technology Corridor (CMVRTC) Oak Ridge National Laboratory Safety Security Vehicle Technologies Research Brief T he Commercial Motor Vehicle Roadside Technology in Tennessee to demonstrate, test, evaluation, and showcase innovative commercial motor vehicle (CMV) safety

270

Commercial Vehicle Safety Alliance Commercial Vehicle Safety Alliance  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Alliance Alliance Commercial Vehicle Safety Alliance North American Standard Level VI Inspection Program Update: Ensuring Safe Transportation of Radioactive Material Carlisle Smith Director, Hazardous Materials Programs Commercial Vehicle Safety Alliance Email: carlisles@cvsa.org Phone: 301-830-6147 CVSA Levels of Inspections Level I Full inspection Level II Walk Around - Driver - Vehicle Level III Driver - Paperwork Level IV Special Project - Generally focus on one item CVSA Levels of Inspections Level V Vehicle Only Level VI Enhanced RAM Level VII Jurisdictional Mandated * 8 basic classes/year held in various states * Prerequisites: CVSA Level I and HAZMAT certified * Industry attends course * To date 135 classes/2268 attendees * Currently 702 certified Level VI

271

Commercial SNF Accident Release Fractions  

Science Conference Proceedings (OSTI)

The purpose of this analysis is to specify and document the total and respirable fractions for radioactive materials that could be potentially released from an accident at the repository involving commercial spent nuclear fuel (SNF) in a dry environment. The total and respirable release fractions are used to support the preclosure licensing basis for the repository. The total release fraction is defined as the fraction of total commercial SNF assembly inventory, typically expressed as an activity inventory (e.g., curies), of a given radionuclide that is released to the environment from a waste form. Radionuclides are released from the inside of breached fuel rods (or pins) and from the detachment of radioactive material (crud) from the outside surfaces of fuel rods and other components of fuel assemblies. The total release fraction accounts for several mechanisms that tend to retain, retard, or diminish the amount of radionuclides that are available for transport to dose receptors or otherwise can be shown to reduce exposure of receptors to radiological releases. The total release fraction includes a fraction of airborne material that is respirable and could result in inhalation doses; this subset of the total release fraction is referred to as the respirable release fraction. Accidents may involve waste forms characterized as: (1) bare unconfined intact fuel assemblies, (2) confined intact fuel assemblies, or (3) canistered failed commercial SNF. Confined intact commercial SNF assemblies at the repository are contained in shipping casks, canisters, or waste packages. Four categories of failed commercial SNF are identified: (1) mechanically and cladding-penetration damaged commercial SNF, (2) consolidated/reconstituted assemblies, (3) fuel rods, pieces, and debris, and (4) nonfuel components. It is assumed that failed commercial SNF is placed into waste packages with a mesh screen at each end (CRWMS M&O 1999). In contrast to bare unconfined fuel assemblies, the container that confines the fuel assemblies could provide an additional barrier for diminishing the total release fraction should the fuel rod cladding breach during an accident. This analysis, however, does not take credit for the additional barrier and establishes only the total release fractions for bare unconfined intact commercial SNF assemblies, which may be conservatively applied to confined intact commercial I SNF assemblies.

J. Schulz

2004-11-05T23:59:59.000Z

272

Existing Commercial Reference Buildings Constructed In or After 1980 -  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Existing Commercial Reference Buildings Constructed In or After Existing Commercial Reference Buildings Constructed In or After 1980 - Archive Existing Commercial Reference Buildings Constructed In or After 1980 - Archive Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available. Archived Reference Buildings Building Type Version 1.2_4.0 updated 3/12/10 Large office (ZIP 2.3 MB) Medium office (ZIP 2.2 MB) Small office (ZIP 1.4 MB) Warehouse (ZIP 980 KB) Stand-alone retail (ZIP 2 MB) Strip mall (ZIP 2.3 MB) Primary school (ZIP 2.7 MB) Secondary school (ZIP 3.9 MB) Supermarket (ZIP 2.2 MB) Quick service restaurant (ZIP 1.1 MB)

273

Development of a California commercial building benchmarking database  

SciTech Connect

Building energy benchmarking is a useful starting point for commercial building owners and operators to target energy savings opportunities. There are a number of tools and methods for benchmarking energy use. Benchmarking based on regional data can provides more relevant information for California buildings than national tools such as Energy Star. This paper discusses issues related to benchmarking commercial building energy use and the development of Cal-Arch, a building energy benchmarking database for California. Currently Cal-Arch uses existing survey data from California's Commercial End Use Survey (CEUS), a largely underutilized wealth of information collected by California's major utilities. Doe's Commercial Building Energy Consumption Survey (CBECS) is used by a similar tool, Arch, and by a number of other benchmarking tools. Future versions of Arch/Cal-Arch will utilize additional data sources including modeled data and individual buildings to expand the database.

Kinney, Satkartar; Piette, Mary Ann

2002-05-17T23:59:59.000Z

274

Existing Commercial Reference Buildings Constructed Before 1980 - Archive  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Existing Commercial Reference Buildings Constructed Before 1980 - Existing Commercial Reference Buildings Constructed Before 1980 - Archive Existing Commercial Reference Buildings Constructed Before 1980 - Archive Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available. Archived Reference Buildings Building Type Version 1.2_4.0 updated 3/12/10 Large office (ZIP 2.3 MB) Medium office (ZIP 2.2 MB) Small office (ZIP 1.4 MB) Warehouse (ZIP 980 KB) Stand-alone retail (ZIP 2 MB) Strip mall (ZIP 2.3 MB) Primary school (ZIP 2.7 MB) Secondary school (ZIP 3.9 MB) Supermarket (ZIP 2.2 MB) Quick service restaurant (ZIP 1.1 MB) Full service restaurant

275

Energy Storage Systems 2007 Peer Review - Utility & Commercial Applications  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7 Peer Review - Utility & Commercial 7 Peer Review - Utility & Commercial Applications Presentations Energy Storage Systems 2007 Peer Review - Utility & Commercial Applications Presentations The U.S. DOE Energy Storage Systems Program (ESS) held an annual peer review on September 27, 2007 in San Francisco, CA. Eighteen presentations were divided into categories; those related to utility, commercial, and rail applications of advanced energy storage systems are below. Other presentation categories were: Economics - Benefit Studies and Environment Benefit Studies International Energy Storage Programs Power Electronics Innovations in Energy Storage Systems ESS 2007 Peer Review - Application of Large-Scale ESS in AEP - Ali Nourai, AEP.pdf ESS 2007 Peer Review - Iowa Stored Energy Park - Kent Holst, ISEP.pdf

276

Building Technologies Office: Commercial Reference Buildings  

NLE Websites -- All DOE Office Websites (Extended Search)

Commercial Reference Commercial Reference Buildings to someone by E-mail Share Building Technologies Office: Commercial Reference Buildings on Facebook Tweet about Building Technologies Office: Commercial Reference Buildings on Twitter Bookmark Building Technologies Office: Commercial Reference Buildings on Google Bookmark Building Technologies Office: Commercial Reference Buildings on Delicious Rank Building Technologies Office: Commercial Reference Buildings on Digg Find More places to share Building Technologies Office: Commercial Reference Buildings on AddThis.com... About Take Action to Save Energy Activities 179d Tax Calculator Advanced Energy Design Guides Advanced Energy Retrofit Guides Building Energy Data Exchange Specification Buildings Performance Database Data Centers Energy Asset Score

277

Building Technologies Office: Commercial Building Partnership Opportunities  

NLE Websites -- All DOE Office Websites (Extended Search)

Commercial Building Commercial Building Partnership Opportunities with the Department of Energy to someone by E-mail Share Building Technologies Office: Commercial Building Partnership Opportunities with the Department of Energy on Facebook Tweet about Building Technologies Office: Commercial Building Partnership Opportunities with the Department of Energy on Twitter Bookmark Building Technologies Office: Commercial Building Partnership Opportunities with the Department of Energy on Google Bookmark Building Technologies Office: Commercial Building Partnership Opportunities with the Department of Energy on Delicious Rank Building Technologies Office: Commercial Building Partnership Opportunities with the Department of Energy on Digg Find More places to share Building Technologies Office: Commercial

278

Philadelphia Gas Works - Commercial and Industrial Equipment...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

available to all PGW commercial and industrial customers installing high efficiency boilers or eligible commercial food service equipment. All equipment must meet program...

279

Commercial Real Estate: Looking for Energy Solutions  

NLE Websites -- All DOE Office Websites (Extended Search)

1-100 Energy Performance Rating for eligible commercial building types, and an Energy Use Intensity index for all commercial building types. > Set Energy Performance Goals. SPPs...

280

NREL: Energy Systems Integration - Residential and Commercial...  

NLE Websites -- All DOE Office Websites (Extended Search)

Residential and Commercial Integration Energy systems integration R&D at the small-scale, residential and commercial integration level encompasses diverse technologies such as...

Note: This page contains sample records for the topic "large commercial critical" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Energy Conservation and Commercialization in Gujarat: Report...  

Open Energy Info (EERE)

Conservation and Commercialization in Gujarat: Report On Demand Side Management (DSM) In Gujarat Jump to: navigation, search Name Energy Conservation and Commercialization in...

282

Efficient thermal energy distribution in commercial buildings...  

NLE Websites -- All DOE Office Websites (Extended Search)

Efficient thermal energy distribution in commercial buildings -- Final Report Title Efficient thermal energy distribution in commercial buildings -- Final Report Publication Type...

283

OTEC- Commercial Lighting Retrofit Rebate Program  

Energy.gov (U.S. Department of Energy (DOE))

The Oregon Trail Electric Consumers Cooperative (OTEC) offers a commercial lighting retrofit program that provides rebates for commercial businesses that change existing lighting to more energy...

284

Trends in Commercial Buildings--Introduction  

U.S. Energy Information Administration (EIA) Indexed Site

> Special Reports > Trends in Commercial Buildings Trends: Buildings and Floorspace Energy Consumption and Energy Sources Overview: The Commercial Buildings Energy Consumption...

285

Trends in Commercial Buildings--Overview  

Gasoline and Diesel Fuel Update (EIA)

Home > Trends in Commercial Buildings > Commercial Buildings Energy Consumption Survey Survey Methodology Sampling Error, Standard Errors, and Relative Standard Errors The...

286

Coldwater Board of Public Utilities - Commercial & Industrial...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

here Home Savings Coldwater Board of Public Utilities - Commercial & Industrial Lighting Rebate Program Coldwater Board of Public Utilities - Commercial & Industrial Lighting...

287

Central Hudson Gas & Electric (Electric) - Commercial Lighting...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

You are here Home Savings Central Hudson Gas & Electric (Electric) - Commercial Lighting Rebate Program Central Hudson Gas & Electric (Electric) - Commercial Lighting Rebate...

288

Technology Transfer Commercialization Act of 2000 | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Technology Transfer Commercialization Act of 2000 Technology Transfer Commercialization Act of 2000 PUBLIC LAW 106-404-NOV. 1, 2000 To improve the ability of Federal agencies to...

289

Commercial Lighting and LED Lighting Incentives  

Energy.gov (U.S. Department of Energy (DOE))

Incentives for energy efficient commercial lighting equipment as well as commercial LED lighting equipment are available to businesses under the Efficiency Vermont Lighting and LED Lighting...

290

Alternative Fuels Data Center: Biofuels Commercialization Grants  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Biofuels Commercialization Grants to someone by E-mail Share Alternative Fuels Data Center: Biofuels Commercialization Grants on Facebook Tweet about Alternative Fuels Data Center:...

291

Commercialization Support for Business Program (Manitoba, Canada)  

Energy.gov (U.S. Department of Energy (DOE))

The Commercialization Support for Business Program supports product and process commercialization and business development in all sectors and all regions of the province.

292

Canadian Fuel Cell Commercialization Roadmap Update: Progress...  

Open Energy Info (EERE)

Fuel Cell Commercialization Roadmap Update: Progress of Canada's Hydrogen and Fuel Cell Industry Jump to: navigation, search Name Canadian Fuel Cell Commercialization Roadmap...

293

Commercial Building Asset Rating Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1 eere.energy.gov 1 eere.energy.gov Commercial Building Asset Rating Program August 23, 2011 12 p.m. ET, 9 a.m. PT Presenter: Cody Taylor PRE-DECISIONAL Information included in this document is for discussion purposes and does not constitute the final program design. FOR INFORMATION ONLY 2 eere.energy.gov Outline * Goals * Scope & schedule * Guiding principles * Program design issues - Metrics - Rating method - Rating scale - Opportunities for efficiency improvement - Quality assurance Please submit clarifying questions during today's webinar via the Q&A function of Live Meeting. 3 eere.energy.gov National Building Rating Program Goals * Facilitate cost-effective investment in energy efficiency and reduce energy use in the commercial building sector * Establish a national standard for voluntary commercial building asset rating

294

Commercially Valuable Smart Grid Data  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

February 4, 2010 1 February 4, 2010 1 Commercially Valuable Smart Grid Data Commercially Valuable Smart Grid Data Question: What is the Department of Energy's (DOE's) approach for ensuring confidentiality of information that contains confidential and/or proprietary information that recipients are required to submit in carrying out their Metrics and Benefits Reporting Plan obligations? Answer: DOE does not anticipate requiring delivery of any "proprietary" information, i.e., confidential information developed at private expense outside the DOE grant. For data developed under a SGIG grant, DOE has the right to obtain and publish such data. However, certain "commercially valuable data" as set forth in more detail below, may be protected from publication.

295

Buildings Energy Data Book: 3.2 Commercial Sector Characteristics  

Buildings Energy Data Book (EERE)

7 7 Commercial Building Median Lifetimes (Years) Building Type Median (1) 66% Survival (2) 33% Survival (2) Assembly 55 40 75 Education 62 45 86 Food Sales 55 41 74 Food Service 50 35 71 Health Care 55 42 73 Large Office 65 46 92 Mercantile & Service 50 36 69 Small Office 58 41 82 Warehouse 58 41 82 Lodging 53 38 74 Other 60 44 81 Note(s): Source(s): 1) PNNL estimates the median lifetime of commercial buildings is 70-75 years. 2) Number of years after which the building survives. For example, a third of the large office buildings constructed today will survive 92 years later. EIA, Assumptions for the Annual Energy Outlook 2011, July 2011, Table 5.2, p. 40; EIA, Model Documentation Report: Commercial Sector 'Demand Module of the National Energy Modeling System, May 2010, p. 30-35; and PNNL, Memorandum: New Construction in the Annual Energy Outlook 2003, Apr. 24,

296

Mission Critical Networking  

SciTech Connect

Mission-Critical Networking (MCN) refers to networking for application domains where life or livelihood may be at risk. Typical application domains for MCN include critical infrastructure protection and operation, emergency and crisis intervention, healthcare services, and military operations. Such networking is essential for safety, security and economic vitality in our complex world characterized by uncertainty, heterogeneity, emergent behaviors, and the need for reliable and timely response. MCN comprise networking technology, infrastructures and services that may alleviate the risk and directly enable and enhance connectivity for mission-critical information exchange among diverse, widely dispersed, mobile users.

Eltoweissy, Mohamed Y.; Du, David H.C.; Gerla, Mario; Giordano, Silvia; Gouda, Mohamed; Schulzrinne, Henning; Youssef, Moustafa

2010-06-01T23:59:59.000Z

297

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Plumbing Products Test Procedure Plumbing Products Test Procedure Sign up for e-mail updates on regulations for this and other products The Department of Energy has proposed to update its test procedures for showerheads, faucets, water closets, urinals,and commercial prerinse spray valves, collectively known as plumbing products. This activity is mandated by the Energy Policy and Conservation Act of 2007 (EPCA). Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a final rule regarding test procedures for showerheads, faucets, water closets, urinals, and commercial prerinse spray valves. 78 FR 62970 (October 23, 2013). Public Meeting Information

298

Commercial thermal distribution systems, Final report for CIEE/CEC  

Science Conference Proceedings (OSTI)

According to the California Energy Commission (CEC 1998a), California commercial buildings account for 35% of statewide electricity consumption, and 16% of statewide gas consumption. Space conditioning accounts for roughly 16,000 GWh of electricity and 800 million therms of natural gas annually, and the vast majority of this space conditioning energy passes through thermal distribution systems in these buildings. In addition, 8600 GWh per year is consumed by fans and pumps in commercial buildings, most of which is used to move the thermal energy through these systems. Research work at Lawrence Berkeley National Laboratory (LBNL) has been ongoing over the past five years to investigate the energy efficiency of these thermal distribution systems, and to explore possibilities for improving that energy efficiency. Based upon that work, annual savings estimates of 1 kWh/ft{sup 2} for light commercial buildings, and 1-2 kWh/ft{sup 2} in large commercial buildings have been developed for the particular aspects of thermal distribution system performance being addressed by this project. Those savings estimates, combined with a distribution of the building stock based upon an extensive stock characterization study (Modera et al. 1999a), and technical penetration estimates, translate into statewide saving potentials of 2000 GWh/year and 75 million thermal/year, as well as an electricity peak reduction potential of 0.7 GW. The overall goal of this research program is to provide new technology and application knowledge that will allow the design, construction, and energy services industries to reduce the energy waste associated with thermal distribution systems in California commercial buildings. The specific goals of the LBNL efforts over the past year were: (1) to advance the state of knowledge about system performance and energy losses in commercial-building thermal distribution systems; (2) to evaluate the potential of reducing thermal losses through duct sealing, duct insulation, and improved equipment sizing; and (3) to develop and evaluate innovative techniques applicable to large buildings for sealing ducts and encapsulating internal duct insulation. In the UCB fan project, the goals were: (1) to develop a protocol for testing, analyzing and diagnosing problems in large commercial building built-up air handling systems, and (2) to develop low-cost measurement techniques to improve short term monitoring practices. To meet our stated goals and objectives, this project: (1) continued to investigate and characterize the performance of thermal distribution systems in commercial buildings; (2) performed energy analyses and evaluation for duct-performance improvements for both small and large commercial buildings; (3) developed aerosol injection technologies for both duct sealing and liner encapsulation in commercial buildings; and (4) designed energy-related diagnostic protocols based on short term measurement and used a benchmarking database to compare subject systems with other measured systems for certain performance metrics. This year's efforts consisted of the following distinct tasks: performing characterization measurements for five light commercial building systems and five large-commercial-building systems; analyzing the potential for including duct performance in California's Energy Efficiency Standards for Residential and Non-Residential Buildings (Title 24), including performing energy and equipment sizing analyses of air distribution systems using DOE 2.1E for non-residential buildings; conducting laboratory experiments, field experiments, and modeling of new aerosol injection technologies concepts for sealing and coating, including field testing aerosol-based sealing in two large commercial buildings; improving low-cost fan monitoring techniques measurements, and disseminating fan tools by working with energy practitioners directly where possible and publishing the results of this research and the tools developed on a web-site. The final report consists of five sections listed below. Each section includes its related

Xu, Tengfang; Bechu, Olivier; Carrie, Remi; Dickerhoff, Darryl; Fisk, William; Franconi, Ellen; Kristiansen, Oyvind; Levinson, Ronnen; McWilliams, Jennifer; Wang, Duo; Modera, Mark; Webster, Tom; Ring, Erik; Zhang, Qiang; Huizenga, Charlie; Bauman, Fred; Arens, Ed

1999-12-01T23:59:59.000Z

299

Commercial thermal distribution systems, Final report for CIEE/CEC  

SciTech Connect

According to the California Energy Commission (CEC 1998a), California commercial buildings account for 35% of statewide electricity consumption, and 16% of statewide gas consumption. Space conditioning accounts for roughly 16,000 GWh of electricity and 800 million therms of natural gas annually, and the vast majority of this space conditioning energy passes through thermal distribution systems in these buildings. In addition, 8600 GWh per year is consumed by fans and pumps in commercial buildings, most of which is used to move the thermal energy through these systems. Research work at Lawrence Berkeley National Laboratory (LBNL) has been ongoing over the past five years to investigate the energy efficiency of these thermal distribution systems, and to explore possibilities for improving that energy efficiency. Based upon that work, annual savings estimates of 1 kWh/ft{sup 2} for light commercial buildings, and 1-2 kWh/ft{sup 2} in large commercial buildings have been developed for the particular aspects of thermal distribution system performance being addressed by this project. Those savings estimates, combined with a distribution of the building stock based upon an extensive stock characterization study (Modera et al. 1999a), and technical penetration estimates, translate into statewide saving potentials of 2000 GWh/year and 75 million thermal/year, as well as an electricity peak reduction potential of 0.7 GW. The overall goal of this research program is to provide new technology and application knowledge that will allow the design, construction, and energy services industries to reduce the energy waste associated with thermal distribution systems in California commercial buildings. The specific goals of the LBNL efforts over the past year were: (1) to advance the state of knowledge about system performance and energy losses in commercial-building thermal distribution systems; (2) to evaluate the potential of reducing thermal losses through duct sealing, duct insulation, and improved equipment sizing; and (3) to develop and evaluate innovative techniques applicable to large buildings for sealing ducts and encapsulating internal duct insulation. In the UCB fan project, the goals were: (1) to develop a protocol for testing, analyzing and diagnosing problems in large commercial building built-up air handling systems, and (2) to develop low-cost measurement techniques to improve short term monitoring practices. To meet our stated goals and objectives, this project: (1) continued to investigate and characterize the performance of thermal distribution systems in commercial buildings; (2) performed energy analyses and evaluation for duct-performance improvements for both small and large commercial buildings; (3) developed aerosol injection technologies for both duct sealing and liner encapsulation in commercial buildings; and (4) designed energy-related diagnostic protocols based on short term measurement and used a benchmarking database to compare subject systems with other measured systems for certain performance metrics. This year's efforts consisted of the following distinct tasks: performing characterization measurements for five light commercial building systems and five large-commercial-building systems; analyzing the potential for including duct performance in California's Energy Efficiency Standards for Residential and Non-Residential Buildings (Title 24), including performing energy and equipment sizing analyses of air distribution systems using DOE 2.1E for non-residential buildings; conducting laboratory experiments, field experiments, and modeling of new aerosol injection technologies concepts for sealing and coating, including field testing aerosol-based sealing in two large commercial buildings; improving low-cost fan monitoring techniques measurements, and disseminating fan tools by working with energy practitioners directly where possible and publishing the results of this research and the tools developed on a web-site. The final report consists of five sections listed below. Each section includes its related

Xu, Tengfang; Bechu, Olivier; Carrie, Remi; Dickerhoff, Darryl; Fisk, William; Franconi, Ellen; Kristiansen, Oyvind; Levinson, Ronnen; McWilliams, Jennifer; Wang, Duo; Modera, Mark; Webster, Tom; Ring, Erik; Zhang, Qiang; Huizenga, Charlie; Bauman, Fred; Arens, Ed

1999-12-01T23:59:59.000Z

300

Evaluating Rail Transit Criticism  

E-Print Network (OSTI)

This report evaluates criticism of rail transit systems. It examines claims that rail transit is ineffective at increasing public transit ridership and improving transportation system performance, that rail transit investments are not cost effective, and that transit is an outdated form of transportation. It finds that critics often misrepresent issues and use biased and inaccurate analysis. This is a companion to the report Rail Transit in

Todd Litman

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "large commercial critical" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Development and validation of bonded composite doubler repairs for commercial aircraft.  

Science Conference Proceedings (OSTI)

A typical aircraft can experience over 2,000 fatigue cycles (cabin pressurizations) and even greater flight hours in a single year. An unavoidable by-product of aircraft use is that crack, impact, and corrosion flaws develop throughout the aircraft's skin and substructure elements. Economic barriers to the purchase of new aircraft have placed even greater demands on efficient and safe repair methods. The use of bonded composite doublers offers the airframe manufacturers and aircraft maintenance facilities a cost effective method to safely extend the lives of their aircraft. Instead of riveting multiple steel or aluminum plates to facilitate an aircraft repair, it is now possible to bond a single Boron-Epoxy composite doubler to the damaged structure. The FAA's Airworthiness Assurance Center at Sandia National Labs (AANC), Boeing, and Federal Express completed a pilot program to validate and introduce composite doubler repair technology to the U.S. commercial aircraft industry. This project focused on repair of DC-10 fuselage structure and its primary goal was to demonstrate routine use of this repair technology using niche applications that streamline the design-to-installation process. As composite doubler repairs gradually appear in the commercial aircraft arena, successful flight operation data is being accumulated. These commercial aircraft repairs are not only demonstrating the engineering and economic advantages of composite doubler technology but they are also establishing the ability of commercial maintenance depots to safely adopt this repair technique. This report presents the array of engineering activities that were completed in order to make this technology available for widespread commercial aircraft use. Focused laboratory testing was conducted to compliment the field data and to address specific issues regarding damage tolerance and flaw growth in composite doubler repairs. Fatigue and strength tests were performed on a simulated wing repair using a substandard design and a flawed installation. In addition, the new Sol-Gel surface preparation technique was evaluated. Fatigue coupon tests produced Sol-Gel results that could be compared with a large performance database from conventional, riveted repairs. It was demonstrated that not only can composite doublers perform well in severe off-design conditions (low doubler stiffness and presence of defects in doubler installation) but that the Sol-Gel surface preparation technique is easier and quicker to carry out while still producing optimum bonding properties. Nondestructive inspection (NDI) methods were developed so that the potential for disbond and delamination growth could be monitored and crack growth mitigation could be quantified. The NDI methods were validated using full-scale test articles and the FedEx aircraft installations. It was demonstrated that specialized NDI techniques can detect flaws in composite doubler installations before they reach critical size. Probability of Detection studies were integrated into the FedEx training in order to quantify the ability of aircraft maintenance depots to properly monitor these repairs. In addition, Boeing Structural Repair and Nondestructive Testing Manuals were modified to include composite doubler repair and inspection procedures. This report presents the results from the FedEx Pilot Program that involved installation and surveillance of numerous repairs on operating aircraft. Results from critical NDI evaluations are reported in light of damage tolerance assessments for bonded composite doublers. This work has produced significant interest from airlines and aircraft manufacturers. The successful Pilot Program produced flight performance history to establish the durability of bonded composite patches as a permanent repair on commercial aircraft structures. This report discusses both the laboratory data and Pilot Program results from repair installations on operating aircraft to introduce composite doubler repairs into mainstream commercial aircraft use.

Roach, Dennis Patrick; Rackow, Kirk A.

2007-07-01T23:59:59.000Z

302

Covered Product Category: Commercial Fryers  

Energy.gov (U.S. Department of Energy (DOE))

FEMP provides acquisition guidance across a variety of product categories, including commercial fryers, which are an ENERGY STAR-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

303

Covered Product Category: Commercial Boiler  

Energy.gov (U.S. Department of Energy (DOE))

FEMP provides acquisition guidance and Federal efficiency requirements across a variety of product categories, including commercial boilers, which is a FEMP-designated product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

304

Commercial Cool Storage Design Guide  

Science Conference Proceedings (OSTI)

This state-of-the-art handbook provides comprehensive guidance for designing ice and chilled-water storage systems for commercial buildings. HVAC engineers can take advantage of attractive rates and incentives offered by utilities to increase the market for cool storage systems.

1985-05-01T23:59:59.000Z

305

Lighting Controls in Commercial Buildings  

NLE Websites -- All DOE Office Websites (Extended Search)

Lighting Controls in Commercial Buildings Lighting Controls in Commercial Buildings Title Lighting Controls in Commercial Buildings Publication Type Report Year of Publication 2012 Authors Williams, Alison A., Barbara A. Atkinson, Karina Garbesi, Erik Page, and Francis M. Rubinstein Series Title The Journal of the Illuminating Engineering Society of North America Volume 8 Document Number 3 Pagination 161-180 Date Published January ISBN Number 1550-2716 Keywords controls, daylighting, energy, occupancy sensors, tuning. Abstract Researchers have been quantifying energy savings from lighting controls in commercial buildings for more than 30 years. This study provides a meta-analysis of lighting energy savings identified in the literature-240 savings estimates from 88 papers and case studies, categorized into daylighting strategies, occupancy strategies, personal tuning, and institutional tuning. Beginning with an overall average of savings estimates by control strategy, successive analytical filters are added to identify potential biases introduced to the estimates by different analytical approaches. Based on this meta-analysis, the bestestimates of average lighting energy savings potential are 24 percent for occupancy, 28 percent for daylighting, 31 percent for personal tuning, 36 percent for institutional tuning, and 38 percent for multiple approaches. The results also suggest that simulations significantly overestimate (by at least 10 percent) the average savings obtainable from daylighting in actual buildings.

306

Wells Public Utilities - Commercial and Industrial Energy Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial and Industrial Energy Efficiency Rebate Program Wells Public Utilities - Commercial and Industrial Energy Efficiency Rebate Program Eligibility Commercial Fed....

307

Energy Efficiency Fund (Gas) - Commercial and Industrial Energy...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Gas) - Commercial and Industrial Energy Efficiency Programs Energy Efficiency Fund (Gas) - Commercial and Industrial Energy Efficiency Programs Eligibility Commercial Industrial...

308

Commercial Wind Energy Property Valuation | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial Wind Energy Property Valuation Commercial Wind Energy Property Valuation < Back Eligibility Commercial Industrial Utility Savings Category Wind Buying & Making...

309

Energy Information Administration (EIA)- Commercial Buildings ...  

U.S. Energy Information Administration (EIA)

Crude oil, gasoline, heating oil, diesel, ... commercial buildings, manufacturing, ... solar, wind, geothermal, ...

310

Bio-Imaging Technology Transfer and Commercialization ...  

Science Conference Proceedings (OSTI)

Bio-Imaging Technology Transfer and Commercialization Showcase. For Immediate Release: August 25, 2009. ...

2010-12-29T23:59:59.000Z

311

Mike Furey | Technology Commercialization and Partnerships  

Nonproliferation & National Security; Nuclear Science & Technology; Technology Commercialization & Partnerships; Sustainable Energy ...

312

BNL | Technology Commercialization & Partnerships | Call for ...  

Environmental Sciences; ... project management assistance; ... Commercialization Manager at Office of Technology Transfer and Partnerships ...

313

Energy Information Administration (EIA)- Commercial Buildings ...  

U.S. Energy Information Administration (EIA)

Consumption & Efficiency. Energy use in homes, commercial buildings, manufacturing, and transportation. Coal.

314

Number of U.S. Commercial Buildings  

U.S. Energy Information Administration (EIA)

Glossary Home > Households, Buildings & Industry > Energy Efficiency > Commercial Buildings Energy Intensities > Table 2

315

U.S. Commercial Buildings Energy Intensity  

U.S. Energy Information Administration (EIA)

Glossary Home > Households, Buildings & Industry > Energy Efficiency > Commercial Buildings Energy Intensities > Table 5b

316

U.S. Commercial Buildings Energy Intensity  

U.S. Energy Information Administration (EIA)

Glossary Home > Households, Buildings & Industry > Energy Efficiency > Commercial Buildings Energy Intensities > Table 5a

317

Today in Energy - Commercial Consumption & Efficiency  

Reports and Publications (EIA)

Short, timely articles with graphs about recent commercial consumption and efficiency issues and trends

318

U.S. Commercial Buildings Energy Intensity  

U.S. Energy Information Administration (EIA)

Glossary Home > Households, Buildings & Industry > Energy Efficiency > Commercial Buildings Energy Intensities > Table 7a

319

U.S. Commercial Buildings Energy Intensity  

U.S. Energy Information Administration (EIA)

Glossary Home > Households, Buildings & Industry > Energy Efficiency > Commercial Buildings Energy Intensities > Table7c

320

U.S. Commercial Buildings Energy Intensity  

U.S. Energy Information Administration (EIA)

Glossary Home > Households, Buildings & Industry > Energy Efficiency > Commercial Buildings Energy Intensities > Table 7b

Note: This page contains sample records for the topic "large commercial critical" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

COMMERCIALIZATION DEMONSTRATION OF MID-SIZED SUPERCONDUCTING MAGNETIC ENERGY STORAGE TECHNOLOGY FOR ELECTRIC UTILITYAPPLICATIONS  

DOE Green Energy (OSTI)

As an outgrowth of the Technology Reinvestment Program of the 1990s, an Agreement was formed between BWXT and the DOE to promote the commercialization of Superconducting Magnetic Energy Storage (SMES) technology. Business and marketing studies showed that the performance of electric transmission lines could be improved with this SMES technology by stabilizing the line thereby allowing the reserved stability margin to be used. One main benefit sought was to double the capacity and the amount of energy flow on an existing transmission line by enabling the use of the reserved stability margin, thereby doubling revenue. Also, electrical disturbances, power swings, oscillations, cascading disturbances and brown/black-outs could be mitigated and rendered innocuous; thereby improving power quality and reliability. Additionally, construction of new transmission lines needed for increased capacity could be delayed or perhaps avoided (with significant savings) by enabling the use of the reserved stability margin of the existing lines. Two crucial technical aspects were required; first, a large, powerful, dynamic, economic and reliable superconducting magnet, capable of oscillating power flow was needed; and second, an electrical power interface and control to a transmission line for testing, demonstrating and verifying the benefits and features of the SMES system was needed. A project was formed with the goals of commercializing the technology by demonstrating SMES technology for utility applications and to establish a domestic capability for manufacturing large superconducting magnets for both commercial and defense applications. The magnet had very low AC losses to support the dynamic and oscillating nature of the stabilizing power flow. Moreover, to economically interface to the transmission line, the magnet had the largest operating voltage ever made. The manufacturing of that design was achieved by establishing a factory with newly designed and acquired equipment, tooling, methods and skilled personnel. The final magnet system measured 14 feet in diameter, 10 feet in height, and weighed about 35 tons. The superconducting magnet and design technology was successfully implemented and demonstrated. The project was not successfully concluded however; as the critical planned final demonstration was not achieved. The utilities could not understand or clarify their future business needs and the regulatory requirements, because of the deregulation policies and practices of the country. Much uncertainty existed which prevented utilities from defining business plans, including asset allocation and cost recovery. Despite the technical successes and achievements, the commercial development could not be implemented and achieved. Thus, the demonstration of this enhancement to the utilitys transmission system and to the reliability of the nations electrical grid was not achieved. The factory was ultimately discontinued and the technology, equipment and product were placed in storage.

CHARLES M. WEBER

2008-06-24T23:59:59.000Z

322

Technology Transfer and Commercialization Annual Report 2008  

Science Conference Proceedings (OSTI)

The Idaho National Laboratory (INL) is a Department of Energy (DOE) multi-program national laboratory that conducts research and development in all DOE mission areas. Like all other federal laboratories, INL has a statutory, technology transfer mission to make its capabilities and technologies available to all federal agencies, to state and local governments, and to universities and industry. To fulfill this mission, INL encourages its scientific, engineering, and technical staff to disclose new inventions and creations to ensure the resulting intellectual property is captured, protected, and made available to others who might benefit from it. As part of the mission, intellectual property is licensed to industrial partners for commercialization, creating jobs and delivering the benefits of federally funded technology to consumers. In other cases, unique capabilities are made available to other federal agencies or to regional small businesses to solve specific technical challenges. In other interactions, INL employees work cooperatively with researchers and other technical staff of our partners to further develop emerging technologies. This report is a catalog of selected INL technology transfer and commercialization transactions during this past year. The size and diversity of INL technical resources, coupled with the large number of relationships with other organizations, virtually ensures that a report of this nature will fail to capture all interactions. Recognizing this limitation, this report focuses on transactions that are specifically authorized by technology transfer legislation (and corresponding contractual provisions) or involve the transfer of legal rights to technology to other parties. This report was compiled from primary records, which were readily available to the INLs Office of Technology Transfer & Commercialization. The accomplishments cataloged in the report, however, reflect the achievements and creativity of the highly skilled researchers, technicians, support staff, and operators of the INL workforce. Their achievements and recognized capabilities are what make the accomplishments cataloged here possible. Without them, none of these transactions would occur.

Michelle R. Blacker

2008-12-01T23:59:59.000Z

323

Energy Optimization (Electric) - Commercial Efficiency Program | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Optimization (Electric) - Commercial Efficiency Program Energy Optimization (Electric) - Commercial Efficiency Program Energy Optimization (Electric) - Commercial Efficiency Program < Back Eligibility Commercial Industrial Savings Category Other Home Weatherization Commercial Weatherization Sealing Your Home Heating & Cooling Commercial Heating & Cooling Cooling Manufacturing Ventilation Construction Heat Pumps Appliances & Electronics Commercial Lighting Lighting Water Heating Windows, Doors, & Skylights Maximum Rebate General: See program web site Custom: 50% of project cost Program Info Expiration Date 12/31/2013 State Michigan Program Type Utility Rebate Program Rebate Amount Custom: $0.06/kWh/yr saved CFL Bulbs: $1 - $5 CFL Fixtures: $22/fixture High Performance T8 Lighting Retrofit: $4-$20/fixture retrofit

324

Flathead Electric Cooperative - Commercial Lighting Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

You are here You are here Home » Flathead Electric Cooperative - Commercial Lighting Rebate Program Flathead Electric Cooperative - Commercial Lighting Rebate Program < Back Eligibility Agricultural Commercial Industrial Savings Category Appliances & Electronics Commercial Lighting Lighting Heating & Cooling Commercial Heating & Cooling Maximum Rebate 70% of project cost Program Info State Montana Program Type Utility Rebate Program Rebate Amount Retrofit Lighting: $3 - $400 per unit New Construction Lighting: $10 - $50 per unit Provider Flathead Electric Cooperative Flathead Electric Cooperative, in conjunction with Bonneville Power Administration, encourages energy efficiency in the commercial sector by providing a commercial lighting retro-fit rebate program and a new

325

Massachusetts Municipal Commercial Industrial Incentive Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Massachusetts Municipal Commercial Industrial Incentive Program Massachusetts Municipal Commercial Industrial Incentive Program Massachusetts Municipal Commercial Industrial Incentive Program < Back Eligibility Commercial Industrial Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Commercial Weatherization Sealing Your Home Cooling Construction Design & Remodeling Manufacturing Other Windows, Doors, & Skylights Ventilation Appliances & Electronics Commercial Lighting Lighting Insulation Water Heating Maximum Rebate Varies depending on utility Program Info Start Date Varies Expiration Date Varies State Massachusetts Program Type Utility Rebate Program Rebate Amount Varies depending on utility Provider Massachusetts Municipal Wholesale Electric Company Certain municipal utilities in Massachusetts, in cooperation with

326

Repository disposal requirements for commercial transuranic wastes (generated without reprocessing)  

SciTech Connect

This report forms a preliminary planning basis for disposal of commercial transuranic (TRU) wastes in a geologic repository. Because of the unlikely prospects for commercial spent nuclear fuel reprocessing in the near-term, this report focuses on TRU wastes generated in a once-through nuclear fuel cycle. The four main objectives of this study were to: develop estimates of the current inventories, projected generation rates, and characteristics of commercial TRU wastes; develop proposed acceptance requirements for TRU wastes forms and waste canisters that ensure a safe and effective disposal system; develop certification procedures and processing requirements that ensure that TRU wastes delivered to a repository for disposal meet all applicable waste acceptance requirements; and identify alternative conceptual strategies for treatment and certification of commercial TRU first objective was accomplished through a survey of commercial producers of TRU wastes. The TRU waste acceptance and certification requirements that were developed were based on regulatory requirements, information in the literature, and from similar requirements already established for disposal of defense TRU wastes in the Waste Isolation Pilot Plant (WIPP) which were adapted, where necessary, to disposal of commercial TRU wastes. The results of the TRU waste-producer survey indicated that there were a relatively large number of producers of small quantities of TRU wastes.

Daling, P.M.; Ludwick, J.D.; Mellinger, G.B.; McKee, R.W.

1986-06-01T23:59:59.000Z

327

Planning a Commercial Fuel Cell Installation  

E-Print Network (OSTI)

Fuel cell power plants represent a unique opportunity for industrial users to combine on-site electricity generation and heat recovery with high efficiencies and no significant environmental releases. Thus in some circumstances, the fuel cell may be the best option for industrial cogeneration in locations with environmental restrictions. Because of the modular nature of fuel cell plants, unit ratings can be easily tailored for specific user needs. Bechtel is currently working with International Fuel Cells on plant design and marketing for the 11 MW PC23 Fuel Cell Power Plant program, now being offered for electric utility applications. The utility industry offers a nearly uniform market large enough to permit recovery of design, commercial development and manufacturing start-up costs for a standardized plant. This paper discusses the features of these plants that will contribute to the high availability needed for industrial applications. The added advantages of powering the fuel cell with the hydrogen-rich feedstocks often available in refinery and chemical plants and operating in a cogeneration mode are presented as further incentives for anticipating development of commercial, units for industrial applications.

Bowden, J. R.; May, G. W.

1986-06-01T23:59:59.000Z

328

RECs: Tapping Into The Commercial Customer  

NLE Websites -- All DOE Office Websites (Extended Search)

June 2004 issue June 2004 issue Copyright © 2004 Zackin Publications Inc. All Rights Reserved. RECs: Tapping Into The Commercial Customer Making the business case for renewable energy certificates bought by large corporations. BY CRAIG HANSON AND VINCE VAN SON I n last month's issue, we introduced the renewable energy certificate (REC), a relatively new product that represents the environmental and other non-electrical attributes associated with 1 MWh of electricity generated from renewable resources. We also reported that several major U.S. corporations, including Alcoa, Cargill Dow LLC, Delphi Corp., DuPont, Interface, Johnson & Johnson, Kinko's, Pitney Bowes and Sta- ples, completed the nation's largest aggre- gate corporate purchase of RECs in Sep- tember 2003. Together, these members of

329

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Clothes Washers Clothes Washers Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of residential clothes washers since 1988. Residential clothes washers use a water solution of soap and/or detergent and mechanical agitation or other movement to clean clothes. These include automatic, semi-automatic, and "other" clothes washers (known collectively as "clothes washer products"). This category does not include commercial clothes washers used in commercial settings, multifamily housing, or coin laundries. Standards put in place in 1994, 2004, and 2007 will save approximately 16.4 quads of energy and result in approximately $346.2 billion in energy bill savings for products shipped from 1994-2036. The standards will avoid about 870.2 million metric tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of about 170.6 million automobiles.

330

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

High-Intensity Discharge Lamps High-Intensity Discharge Lamps Sign up for e-mail updates on regulations for this and other products There are currently no energy conservation standards for high-intensity discharge (HID) lamps. HID lamps are electric discharge lamps and include high-pressure sodium, mercury vapor, and metal halide lamps. HID lamps require an HID ballast to start and regulate electric current flow through the lamp. HID lamps are used in street and roadway lighting, area lighting such as for parking lots and plazas, industrial and commercial building interior lighting, security lighting for commercial, industrial, and residential spaces, and landscape lighting. The Standards and Test Procedures for this product are related to Rulemaking for High Intensity Discharge Lamps Energy Conservation Standard and Rulemaking for High Intensity Discharge Lamps Test Procedures.

331

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Single Package Vertical Air Conditioners and Heat Pumps Single Package Vertical Air Conditioners and Heat Pumps Sign up for e-mail updates on regulations for this and other products Manufacturers have been required to comply with the Department of Energy's energy conservation standards for single package vertical air conditioners and heat pumps as a separate equipment class since 2008. Before 2010, this equipment was regulated under the broader scope of commercial air conditioning and heating equipment. Single package vertical air conditioners and heat pumps are commercial air conditioning and heating equipment with its main components arranged in a vertical fashion. They are mainly used in modular classrooms, modular office buildings, telecom shelters, and hotels, and are typically installed on the outside of an exterior wall or in a closet against an exterior wall but inside the building.

332

Industrial and Commercial Heat Pump Applications in the United States  

E-Print Network (OSTI)

The energy crisis of 1973 accelerated the development of large-scale heat pumps in the United States. Since that time, the commercial, institutional, and industrial applications of heat pumps for waste heat recovery have expanded. This paper reviews the trends in heat pump cycle developments and discusses both the closed vapor compression cycle and refrigerants most commonly used and the open-cycle mechanical vapor compression heat pumps. Waste heat sources, heat loads served by heat pumps--and typical applications using heat pumps for large-scale space heating, domestic water heating, and industrial process water heating-- are discussed. Typical installations include commercial applications in hotels, high-rise apartments and condominiums, and office buildings. Institutional installations discussed include hospitals, universities, wastewater treatment plants, and airport terminals. Industrial applications largely center on food processing industries, feedwater heating, metal fabricating, and other industries. Reference is also made to other applications and alternative energy sources now gaining acceptance, including groundwater/geothermal water.

Niess, R. C.

1986-06-01T23:59:59.000Z

333

Cooling commercial buildings with off-peak power  

Science Conference Proceedings (OSTI)

Large commercial buildings use more electricity for cooling than for heating, and can account for 40% of summer peak demand. A cool storage technique in which compressors chill or freeze water during off-peak periods and the water is circulated during peak hours is in use in 100 commercial buildings. Reports indicate that these systems are economical, although little information is available, but engineers are hesitant to incorporate them because of possible damage from leaks or rust and other uncertainties. The Electric Power Research Institute is evaluating the performance of several systems to answer some of the operating and maintenance questions raised by engineers. 3 references, 3 figures. (DCK)

Lihach, N.; Rabl, V.

1983-10-01T23:59:59.000Z

334

Performance Metrics for Commercial Buildings  

SciTech Connect

Commercial building owners and operators have requested a standard set of key performance metrics to provide a systematic way to evaluate the performance of their buildings. The performance metrics included in this document provide standard metrics for the energy, water, operations and maintenance, indoor environmental quality, purchasing, waste and recycling and transportation impact of their building. The metrics can be used for comparative performance analysis between existing buildings and industry standards to clarify the impact of sustainably designed and operated buildings.

Fowler, Kimberly M.; Wang, Na; Romero, Rachel L.; Deru, Michael P.

2010-09-30T23:59:59.000Z

335

Polychlorinated biphenyls in commercial buildings  

SciTech Connect

The Bonneville Power Administration (Bonneville) is planning to implement a conservation acquisition program in new and existing commercial buildings. In anticipation of that program, Bonneville is examining the potential environmental effects of conservation measures in commercial buildings. An important conservation measure is the installation of new energy-efficient lighting fixtures. Some of the old lighting fixtures that these new lights will be replacing were manufactured before 1978, when polychlorinated biphenyls (PCBs) were still used in the capacitors of the lighting ballasts. This report focuses on a summary of information about PCBs in fluorescent light fixtures manufactured before 1978. A key issue associated with these PCBs is the potential effect of lamp change-outs on ballast failure. The US Environmental Protection Agency (EPA) speculates that installing energy-efficient lamps in old, PCB-laden ballasts may contribute to ballast failure and PCB leaks, which is addressed in Section 3 of this report. Section 2 discusses applicable standards and regulations; Section 4 describes PCB concentrations in commercial buildings. Sections 5 and 6 discuss cleanup practices and disposal options. 4 tabs.

Baechler, M.C.; Foley, L.O.; Jarnagin, R.E.

1990-09-01T23:59:59.000Z

336

Nuclear multifragmentation critical exponents  

SciTech Connect

In a recent Letter, cited in a reference, the EoS collaboration presented data of fragmentation of 1 A GeV gold nuclei incident on carbon. By analyzing moments of the fragment charge distribution, the authors claim to determine the values of the critical exponents {gamma}, {beta}, and {tau} for finite nuclei. These data represent a crucial step forward in the understanding of the physics of nuclear fragmentation. However, as shown in this paper, the analysis presented in the cited reference is not sufficient to support the claim that the critical exponents for nuclear fragmentation have been unambiguously determined.

Bauer, W. [Washington Univ., Seattle, WA (United States). Inst. for Nuclear Theory]|[National Superconducting Cyclotron Lab., East Lansing, MI (United States); Friedman, W.A. [Washington Univ., Seattle, WA (United States). Inst. for Nuclear Theory]|[Univ. of Wisconsin, Madison, WI (United States). Dept. of Physics

1995-12-31T23:59:59.000Z

337

Price Server System for Automated Critical Peak Pricing  

NLE Websites -- All DOE Office Websites (Extended Search)

Price Server System for Automated Critical Peak Pricing Price Server System for Automated Critical Peak Pricing Speaker(s): David S. Watson Date: June 3, 2005 - 12:00pm Location: 90-3148 Overview of current California Energy Commission (CEC)/Demand Response Research Center (DRRC) Auto-CPP project: This summer, some select commercial CPP customers of PG&E will have the option of joining the Automated Critical Peak Pricing pilot. The pilot will have the same tariffs as standard CPP programs, but will include an added feature: automated shedding of electric loads. Through use of the Price Server System, day-ahead CPP event signals initiated by PG&E will ultimately cause electric loads to be automatically curtailed on commercial customer sites. These optional predetermined shed strategies will occur without

338

Performance and Electrical Characterization Tests on a Microturbine Commercial Prototype - Part II  

Science Conference Proceedings (OSTI)

EPRI is testing various commercial microturbine generators (MTGs) to verify performance claims, identify any critical technology issues, and assess viability of units for utility applications. This report provides test results on two commercial prototype microturbine generators. The units were identical except that the first unit could only operate in the grid-parallel mode whereas the second unit had the capability to operate in both the grid-parallel and grid-independent modes. The tests continue earli...

2000-12-11T23:59:59.000Z

339

Glossary of nuclear criticality terms  

SciTech Connect

This is a glossary of terms generally encountered in the literature of nuclear criticality and criticality safety. Terms sometimes misused are emphasized. 7 refs.

Paxton, H.C.

1989-10-01T23:59:59.000Z

340

Trends in Commercial Buildings--Introduction  

U.S. Energy Information Administration (EIA) Indexed Site

Home > Commercial > Commercial Buildings Home > Special Home > Commercial > Commercial Buildings Home > Special Reports > Trends in Commercial Buildings Trends: Buildings and Floorspace Energy Consumption and Energy Sources Overview: The Commercial Buildings Energy Consumption Survey (CBECS) Trends in the Commercial Buildings Sector Since 1978, the Energy Information Administration has collected basic statistical information from three of the major end-use sectors— residential, and industrial— periodic energy consumption surveys. Each survey is a snapshot of how energy is used in the year of the survey; the series of surveys in each sector reveals the trends in energy use for the sector. Introduction The Commercial Buildings Energy Consumption Survey (CBECS) collects data from a sample of buildings representative of the commercial buildings

Note: This page contains sample records for the topic "large commercial critical" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Overview of Commercial Buildings, 2003 - Full Report  

U.S. Energy Information Administration (EIA) Indexed Site

Full Report Full Report Energy Information Administration > Commercial Buildings Energy Consumption Survey > Overview of Commercial Buildings Overview of Commercial Buildings, 2003 Introduction The Energy Information Administration conducts the Commercial Buildings Energy Consumption Survey (CBECS) to collect information on energy-related building characteristics and types and amounts of energy consumed in commercial buildings in the United States. In 2003, CBECS reports that commercial buildings: ● total nearly 4.9 million buildings ● comprise more than 71.6 billion square feet of floorspace ● consumed more than 6,500 trillion Btu of energy, with electricity accounting for 55 percent and natural gas 32 percent (Figure 1) ●

342

Barron Electric Cooperative - Commercial, Industrial, and Agricultural  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Barron Electric Cooperative - Commercial, Industrial, and Barron Electric Cooperative - Commercial, Industrial, and Agricultural Energy Efficiency Rebate Program Barron Electric Cooperative - Commercial, Industrial, and Agricultural Energy Efficiency Rebate Program < Back Eligibility Agricultural Commercial Industrial Savings Category Other Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Commercial Lighting Lighting Manufacturing Maximum Rebate $10,000 per account, not to exceed 20% of cost Scroll Refrigeration Compressors: $500 Variable Speed/Frequency Drive Motor: $500 Variable Speed Compressed Air Motor: $500 Energy Audit: One in Five Years Program Info State Wisconsin Program Type Utility Rebate Program Rebate Amount Energy Audit: Free General Lighting: $1 - $15/unit LED Lamps: $2/bulb

343

Burlington Electric Department - Commercial Energy Efficiency Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Burlington Electric Department - Commercial Energy Efficiency Burlington Electric Department - Commercial Energy Efficiency Rebate Program Burlington Electric Department - Commercial Energy Efficiency Rebate Program < Back Eligibility Commercial Savings Category Manufacturing Appliances & Electronics Heating & Cooling Commercial Heating & Cooling Heating Heat Pumps Commercial Lighting Lighting Maximum Rebate Rebates exceeding $5,000 require pre-approval by BED prior to purchase Buildings exceeding 10,000 square feet must consult BED regarding rebates prior to purchase Program Info State Vermont Program Type Utility Rebate Program Rebate Amount Lighting: See Program Website HVAC Air Conditioners/Heat Pumps: $50 - $100/ton Integrated Dual Enthalpy Economizer Controls: $250/controlled unit Ventilation Fans: $35 - $60

344

Roseville Electric - Commercial Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial Energy Efficiency Rebate Program Commercial Energy Efficiency Rebate Program Roseville Electric - Commercial Energy Efficiency Rebate Program < Back Eligibility Commercial Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Other Appliances & Electronics Commercial Lighting Lighting Home Weatherization Insulation Design & Remodeling Windows, Doors, & Skylights Program Info Expiration Date 6/30/2013 State California Program Type Utility Rebate Program Rebate Amount Unitary AC/Heat Pump: $120/ton or $500/ton Package Terminal AC/Heat Pumps: $125/unit Variable Frequency Drive: $120/hp Variable Speed Motor: $75/hp Window Film: $4/sq ft Shade Tree: $30/tree Desktop Computer Network Controller: $10/computer Cold Cathode Lamps: $4/lamp Ceramic Metal Halide: $20/lamp

345

Liberty Utilities (Electric) - Commercial Energy Efficiency Incentive  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Liberty Utilities (Electric) - Commercial Energy Efficiency Liberty Utilities (Electric) - Commercial Energy Efficiency Incentive Programs Liberty Utilities (Electric) - Commercial Energy Efficiency Incentive Programs < Back Eligibility Commercial Industrial Local Government Schools Savings Category Heating & Cooling Commercial Heating & Cooling Heating Cooling Manufacturing Other Construction Heat Pumps Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Custom Incentives: amount that buys down the cost of the project to a 1 year simple payback Program Info State New Hampshire Program Type Utility Rebate Program Rebate Amount Custom Retrofits and Engineering Studies: 50% of project cost Fluorescent Lighting: $10-$50 High Bay: $70 or $100 (retrofit) Metal Halide: $50 or $70 LED Exit Signs: $12 LED Traffic Signals: $50

346

Liberty Utilities (Gas) - Commercial Energy Efficiency Programs |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Liberty Utilities (Gas) - Commercial Energy Efficiency Programs Liberty Utilities (Gas) - Commercial Energy Efficiency Programs Liberty Utilities (Gas) - Commercial Energy Efficiency Programs < Back Eligibility Commercial Industrial Institutional Local Government Schools State Government Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Commercial Weatherization Other Construction Manufacturing Appliances & Electronics Water Heating Windows, Doors, & Skylights Maximum Rebate Custom Projects: $100,000 (existing facilities); $250,000 (new construction) Energy Efficiency Engineering Study: $10,000 Steam Traps: $2500 Programmable Thermostats: up to five units Boiler Reset Controls: up to two units Program Info State New Hampshire Program Type Utility Rebate Program Rebate Amount

347

Overview of Commercial Buildings, 2003 - Full Report  

U.S. Energy Information Administration (EIA) Indexed Site

Introduction Introduction Home > Households, Buildings & Industry > Commercial Buildings Energy Consumption Survey (CBECS) > Overview of Commercial Buildings Print Report: PDF Overview of Commercial Buildings, 2003 Introduction | Trends | Major Characteristics Introduction The Energy Information Administration conducts the Commercial Buildings Energy Consumption Survey (CBECS) to collect information on energy-related building characteristics and types and amounts of energy consumed in commercial buildings in the United States. In 2003, CBECS reports that commercial buildings: total nearly 4.9 million buildings comprise more than 71.6 billion square feet of floorspace consumed more than 6,500 trillion Btu of energy, with electricity accounting for 55 percent and natural gas 32 percent (Figure 1)

348

Criticality issues with highly enriched fuels in a repository environment  

SciTech Connect

This paper presents preliminary analysis of a volcanic tuff repository containing a combination of low enrichment commercial spent nuclear fuels (SNF) and DOE-owned SNF packages. These SNFs were analyzed with respect to their criticality risks. Disposal of SNF packages containing significant fissile mass within a geologic repository must comply with current regulations relative to criticality safety during transportation and handling within operational facilities. However, once the repository is closed, the double contingency credits for criticality safety are subject to unremediable degradation, (e.g., water intrusion, continued presence of neutron absorbers in proximity to fissile material, and fissile material reconfiguration). The work presented in this paper focused on two attributes of criticality in a volcanic tuff repository for near-field and far-field scenarios: (1) scenario conditions necessary to have a criticality, and (2) consequences of a nuclear excursion that are components of risk. All criticality consequences are dependent upon eventual water intrusion into the repository and subsequent breach of the disposal package. Key criticality parameters necessary for a critical assembly are: (1) adequate thermal fissile mass, (2) adequate concentration of fissile material, (3) separation of neutron poison from fissile materials, and (4) sufficient neutron moderation (expressed in units of moderator to fissile atom ratios). Key results from this study indicated that the total energies released during a single excursion are minimal (comparable to those released in previous solution accidents), and the maximum frequency of occurrence is bounded by the saturation and temperature recycle times, thus resulting in small criticality risks.

Taylor, L.L. [Lockheed Martin Idaho Technologies Co., Idaho Falls, ID (United States); Sanchez, L.C.; Rath, J.S. [Sandia National Labs., Albuquerque, NM (United States)

1998-03-01T23:59:59.000Z

349

Commercial Building Partners Catalyze High Performance Buildings Across the Nation  

SciTech Connect

In 2008 the US Department of Energy (DOE) launched the Commercial Buildings Partnership (CBP) project to accelerate market adoption of commercially available energy saving technologies into the design process for new and upgraded commercial buildings. The CBP represents a unique collaboration between industry leaders and DOE to develop high performance buildings as a model for future construction and renovation. CBP was implemented in two stages. This paper focuses on lessons learned at Pacific Northwest National Laboratory (PNNL) in the first stage and discusses some partner insights from the second stage. In the first stage, PNNL and the National Renewable Energy Laboratory recruited CBP partners that own large portfolios of buildings. The labs provide assistance to the partners' design teams and make a business case for energy investments.

Baechler, Michael C.; Dillon, Heather E.; Bartlett, Rosemarie

2012-08-01T23:59:59.000Z

350

Commercial Aircraft Corporation of China (Comac) attempts to break the Airbus-Boeing duopoly, will it succeed? : an industry analysis framework applied  

E-Print Network (OSTI)

Using an industry analysis framework, this thesis analyzes whether the recently established Commercial Aircraft Corporation of China (Comac) is likely to break the Boeing-Airbus duopoly in the industry of large commercial ...

Fuentes, Jose L., S.M. Massachusetts Institute of Technology

2011-01-01T23:59:59.000Z

351

Critical Foundations: Protecting America's Infrastructures  

Science Conference Proceedings (OSTI)

Page 1. CRITICAL FOUNDATIONS PROTECTING AMERICA'S INFRASTRUCTURES The Report of the President's Commission ...

352

Only critical information was scanned  

Office of Legacy Management (LM)

Only critical information was scanned. Entire document is available upon request - Click here to email a...

353

Commercial application of laser fusion  

SciTech Connect

The fundamentals of laser-induced fusion, some laser-fusion reactor concepts, and attendant means of utilizing the thermonuclear energy for commercial electric power generation are discussed. Theoretical fusion-pellet microexplosion energy release characteristics are described and the effects of pellet design options on pellet-microexplosion characteristics are discussed. The results of analyses to assess the engineering feasibility of reactor cavities for which protection of cavity components is provided either by suitable ablative materials or by diversion of plasmas by magnetic fields are presented. Two conceptual laser-fusion electric generating stations, based on different laser-fusion reactor concepts, are described.

Booth, L.A.

1976-01-01T23:59:59.000Z

354

Dominion Virginia Power - Commercial Energy Efficiency Programs |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Dominion Virginia Power - Commercial Energy Efficiency Programs Dominion Virginia Power - Commercial Energy Efficiency Programs Dominion Virginia Power - Commercial Energy Efficiency Programs < Back Eligibility Commercial Industrial Savings Category Heating & Cooling Home Weatherization Construction Commercial Weatherization Commercial Heating & Cooling Design & Remodeling Sealing Your Home Ventilation Heat Pumps Appliances & Electronics Commercial Lighting Lighting Program Info Expiration Date March 31, 2013 State Virginia Program Type Utility Rebate Program Rebate Amount Commercial Energy Audit/Incentives: Up to $4,000 Duct Testing/Sealing: $90/ton (20 tons or less) Duct Testing/Sealing: $75/ton (21 tons or more) Dominion Virginia Power provides a number of rebates to customers for the installation of energy efficient equipment and measures.

355

TECHNICAL DOCUMENTATION Commercial Buildings Energy Consumption Survey  

Reports and Publications (EIA)

This is the technical documentation for the public use data set based on the 1992 Commercial Buildings Energy Consumption Survey (CBECS), the national sample survey of commercial buildings and their energy suppliers conducted by the Energy Information Administration.

Information Center

1996-07-01T23:59:59.000Z

356

Analysis of electric vehicle interconnection with commercial  

E-Print Network (OSTI)

Analysis of electric vehicle interconnection with commercial building microgrids Michael Stadler, process, or service by its trade name, trademark, manufacturer, or otherwise, does not necessarily Laboratories America Inc. Analysis of electric vehicle interconnection with commercial building microgrids

357

Commercial/industrial applications spur solar development  

SciTech Connect

Several large commercial buildings with solar systems are examined. The first building mentioned is the La Quinta Motor Inn located in Dallas, Texas. The system supplies approximately 90% of the hot water for the rooms and laundry. The largest solar cooling system is located in Frenchman's Reef, the Holiday Inn, St. Thomas, Virgin Islands. The system was funded by a 75% grant from the Energy Research and Development Administration. In Decatur, Alabama, construction has begun on a solar heating system that will be used at a large soybean oil extraction facility. The project is also sponsored in part by ERDA. The solar panels will be used to air dry the soy beans. The largest solar-powered irrigation system is located in Gila River Ranch southwest of Phoenix, Arizona. The system includes a 50-hp pump capable of delivering up to 10,000 gallons of irrigation water per minute. It operates with 5,500 ft/sup 2/ of parabolic tracking collectors.

Comstock, W.S.

1977-11-01T23:59:59.000Z

358

Columbia Gas of Massachusetts - Commercial Energy Efficiency...  

Open Energy Info (EERE)

Heat recovery, Processing and Manufacturing Equipment, Programmable Thermostats, Steam-system upgrades, Water Heaters, Commercial Cooking Equipment, Tankless Water Heaters...

359

Security Configuration Checklists for IT Commercial Products  

Science Conference Proceedings (OSTI)

Security Configuration Checklists for Commercial IT Products. ... The use of checklists improves the consistency and predictability of system security. ...

2013-01-15T23:59:59.000Z

360

Energy Information Administration (EIA)- Commercial Buildings ...  

U.S. Energy Information Administration (EIA)

Crude oil, gasoline ... representing a variety of industries ... Following the suspension of the 2011 Commercial Buildings Energy Consumption ...

Note: This page contains sample records for the topic "large commercial critical" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Appliances and Commercial Equipment Standards: Guidance  

NLE Websites -- All DOE Office Websites (Extended Search)

Office HOME ABOUT ENERGY EFFICIENT TECHNOLOGIES RESIDENTIAL BUILDINGS COMMERCIAL BUILDINGS APPLIANCE & EQUIPMENT STANDARDS BUILDING ENERGY CODES EERE Building Technologies...

362

Energy Information Administration (EIA)- Commercial Buildings ...  

U.S. Energy Information Administration (EIA)

Energy use in homes, commercial buildings, manufacturing, ... Grundfos, National Trust for Historic Preservation, and Center for Environmental Innovation in Roofing.

363

Technology Commercialization and Partnerships | Brookhaven Lab ...  

Agreement to Commercialize Technology (ACT) Will Reduce Barriers for Intellectual Property Rights, Lab-Business Partnerships. ... Media & Communications Office.

364

Energy Information Administration (EIA)- Commercial Buildings ...  

U.S. Energy Information Administration (EIA)

Energy use in homes, commercial buildings, manufacturing, and transportation. Coal. ... such as principal building activity or energy sources used.

365

certification, compliance and enforcement regulations for Commercial...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

needs to be redone. certification, compliance and enforcement regulations for Commercial Refrigeration Equipment (CRE) More Documents & Publications Regulatory Burden RFI...

366

Energy Information Administration (EIA)- Commercial Buildings ...  

U.S. Energy Information Administration (EIA)

Data from the 1999 Commercial Buildings Energy Consumption Survey ... and energy-using equipment types (heating, cooling, refrigeration, water ...

367

Table Commercial Industrial Vehicle Fuel Electric Power  

U.S. Energy Information Administration (EIA)

State Residential Commercial Industrial Vehicle Fuel Electric Power ... Form EIA?886, Annual Survey of Alternative Fueled Vehicles; ...

368

Technology Commercialization and Partnerships | Evaluation Criteria  

General Information. Menu. Scientific Departments. ... market and business risk assessment and potential for technology transfer. ... Commercialization Analysis.

369

Baltimore Gas & Electric Company (Electric) - Commercial Energy...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Industrial Local Government Nonprofit State Government Savings For Heating & Cooling Commercial Heating & Cooling Cooling Other Heat Pumps Appliances & Electronics...

370

Cyber Security Technologies Call for Commercialization Plans  

Technology commercialization strategy (e.g., in-house manufacturing, partnering with industry leaders, sublicensing, etc.); Business and marketing plan;

371

Energy Information Administration (EIA)- Commercial Buildings ...  

U.S. Energy Information Administration (EIA)

Energy use in homes, commercial buildings, manufacturing, and transportation. Coal. Reserves, production, prices, employ- ment and ... Data Tools & Models ...

372

Guidelines for the Competition - EERE Commercialization Office  

Search Help Commercialization ... Business plan teams may enter multiple ... The following items will be further clarified in the official Terms & ...

373

NREL: Technology Transfer - NREL Commercialization Project ...  

... the flexibility and speed possible under the TCDF were essential to moving the collaboration forward ... Research Facilities; Commercialization ...

374

The 2013 NCMS Nanotechnology Commercialization Study  

Science Conference Proceedings (OSTI)

Presentation Title, The 2013 NCMS Nanotechnology Commercialization Study ... the last decade to study the impact of the National Nanotechnology Initiative.

375

International Fuel Services and Commercial Engagement | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

International Fuel Services and Commercial Engagement Nuclear Reactor Technologies Fuel Cycle Technologies International Nuclear Energy Policy and Cooperation Bilateral...

376

Barron Electric Cooperative - Commercial, Industrial, and Agricultural...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Industrial, and Agricultural Energy Efficiency Rebate Program Barron Electric Cooperative - Commercial, Industrial, and Agricultural Energy Efficiency Rebate Program...

377

Bonneville Power Administration`s Commercial Sector Conservation Market.  

SciTech Connect

Bonneville has, as part of its resource plan, accepted targets for commercial conservation which are quite ambitious. To meet these targets, Bonneville will need to acquire as much cost-effective conservation as possible over the next twelve years. With this in mind, this document explores the relative importance of different commercial market segments and the types of assistance each market needs to install as many cost-effective conservation measures in as many buildings as possible. This document reviews Bonneville`s marketing environment and position, and suggests goals for commercial sector conservation marketing at Bonneville. Then it presents a broad market segmentation and series of additional demographic analyses. These analyses assess what groups of consumers Bonneville must reach to achieve most of the commercial conservation potential and what is needed to reach them. A final section reviews the success of Bonneville programs at reaching various markets. The market segmentation identifies different types of consumers and opportunities which would require distinct program approaches. Four large market segments are identified that have distinct program needs. Then four ``building life-cycle events`` are identified which provide important conservation opportunities and also require distinct program services. This creates a matrix of 16 cells which delineate distinct needs for program marketing. Each of the four key market segments manages at least 20% of the Region`s commercial floorspace.

Gordan, Frederick M. [Pacific Energy Associates, Inc. (United States)

1992-11-10T23:59:59.000Z

378

Critical dynamics and decoherence  

SciTech Connect

We study dynamics of decoherence in a generic model where the environment is driven and undergoes a quantum phase transition. We model the environment by the Ising chain in the transverse field, and assume that the decohering system is a central spin-1/2. We found that when the environment is quenched slowly through the critical point, the decoherence factor of the central spin undergoes rapid decay that encodes the critical exponents of the environment. We also found that decoherence in a non-equilibrated, kink-contaminated, environment can be stronger than in a vacuum one. We derived a remarkably simple analytical expression that describes post-transition decoherence and predicts periodicities involving all system parameters. This research connects the fields of decoherence, quantum phase transitions, and Kibble-Zurek non-equilibrium dynamics.

Damski, Bogdan [Los Alamos National Laboratory; Quan, Haitao T [Los Alamos National Laboratory; Zurek, Wojciech H [Los Alamos National Laboratory

2009-01-01T23:59:59.000Z

379

2007 CBECS Large Hospital Building FAQs  

Gasoline and Diesel Fuel Update (EIA)

FAQs Main Report | Methodology | FAQ | FAQs Main Report | Methodology | FAQ | List of Tables CBECS 2007 - Release date: August 17, 2012 How were the data collected for this study? These data were collected with the 2007 Commercial Building Energy Consumption Survey (CBECS). See the 2007 CBECS Large Hospital Building Methodology Report for details. Why are you publishing estimates only for large hospitals and not the rest of the commercial building population? A majority of the 2007 CBECS buildings were sampled from a frame that used a less expensive experimental method to update the 2003 frame for new construction. After careful analysis, EIA determined that the buildings sampled from this experimental frame were not representative of the commercial building population and therefore the 2007 CBECS sample as a

380

Review of Yucca Mountain Disposal Criticality Studies  

SciTech Connect

The U.S. Department of Energy (DOE), Office of Civilian Radioactive Waste Management, submitted a license application for construction authorization of a deep geologic repository at Yucca Mountain, Nevada, in June of 2008. The license application is currently under review by the U.S. Nuclear Regulatory Commission. However,on March 3, 2010 the DOE filed a motion requesting withdrawal of the license application. With the withdrawal request and the development of the Blue Ribbon Commission to seek alternative strategies for disposing of spent fuel, the status of the proposed repository at Yucca Mountain is uncertain. What is certain is that spent nuclear fuel (SNF) will continue to be generated and some long-lived components of the SNF will eventually need a disposition path(s). Strategies for the back end of the fuel cycle will continue to be developed and need to include the insights from the experience gained during the development of the Yucca Mountain license application. Detailed studies were performed and considerable progress was made in many key areas in terms of increased understanding of relevant phenomena and issues regarding geologic disposal of SNF. This paper reviews selected technical studies performed in support of the disposal criticality analysis licensing basis and the use of burnup credit. Topics include assembly misload analysis, isotopic and criticality validation, commercial reactor critical analyses, loading curves, alternative waste package and criticality control studies, radial burnup data and effects, and implementation of a conservative application model in the criticality probabilistic evaluation as well as other information that is applicable to operations regarding spent fuel outside the reactor. This paper summarizes the work and significant accomplishments in these areas and provides a resource for future, related activities.

Scaglione, John M [ORNL; Wagner, John C [ORNL

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "large commercial critical" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Applicability of ZPR critical experiment data to criticality safety  

SciTech Connect

More than a hundred zero power reactor (ZPR) critical assemblies were constructed, over a period of about three decades, at the Argonne National Laboratory ZPR-3, ZPR-6, ZPR-9 and ZPPR fast critical assembly facilities. To be sure, the original reason for performing these critical experiments was to support fast reactor development. Nevertheless, data from some of the assemblies are well suited to form the basis for valuable, new criticality safety benchmarks. The purpose of this paper is to describe the ZPR data that would be of benefit to the criticality safety community and to explain how these data could be developed into practical criticality safety benchmarks.

Schaefer, R.W.; Aumeier, S.E.; McFarlane, H.F.

1995-12-31T23:59:59.000Z

382

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

remove loose or sticky food. Dishwashing typically consumes two-thirds of all large restaurant and food service operation water use. The water used in this pre-rinsing operation...

383

Trojan PWR Decommissioning: Large Component Removal Project  

Science Conference Proceedings (OSTI)

While the decommissioning of large commercial nuclear plants in the United States is in its infancy, the technical challenges with associated radioactive waste management are clear. This report describes the removal and disposal of four steam generators and one pressurizer from the Trojan nuclear power plant, the first large PWR to be decommissioned in the United States. The report chronicles the problems, successes, and lessons learned in this project, which was completed on schedule and under budget in...

1997-09-29T23:59:59.000Z

384

Research and Commercialization Grants | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Research and Commercialization Grants Research and Commercialization Grants Research and Commercialization Grants < Back Eligibility Utility Fed. Government Commercial Agricultural Investor-Owned Utility State/Provincial Govt Industrial Construction Municipal/Public Utility Local Government Installer/Contractor Rural Electric Cooperative Tribal Government Schools Institutional Systems Integrator Nonprofit General Public/Consumer Transportation Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info Start Date 1999 State Montana Program Type Grant Program Provider Montana Department of Commerce The Board of Research and Commercialization Technology provides grants for renewable resource research and development projects, among other types, to

385

Progress Energy Carolinas - Commercial Energy Efficiency Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Efficiency Program Energy Efficiency Program Progress Energy Carolinas - Commercial Energy Efficiency Program < Back Eligibility Commercial Construction Industrial Multi-Family Residential Nonprofit Schools Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Home Weatherization Construction Commercial Weatherization Design & Remodeling Other Heat Pumps Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Custom Projects: 75% of the incremental measure costs Technical Efficiency Studies: 50% of cost up to $10,000-$20,000 Design Incentive (New Construction): $50,000 Program Info Expiration Date 1/1/2013 State South Carolina Program Type Utility Rebate Program Rebate Amount Custom: $0.08 per kW hour saved annually CFL Lamps (Retrofit Only): $1.50

386

Trends in Commercial Buildings--Overview  

U.S. Energy Information Administration (EIA) Indexed Site

Home > Trends in Commercial Buildings > Commercial Home > Trends in Commercial Buildings > Commercial Buildings Energy Consumption Survey Survey Methodology Sampling Error, Standard Errors, and Relative Standard Errors The Commercial Buildings Energy Consumption Survey The commercial sector consists of business establishments and other organizations that provide services. The sector includes service businesses, such as retail and wholesale stores, hotels and motels, restaurants, and hospitals, as well as a wide range of buildings that would not be considered “commercial” in a traditional economic sense, such as public schools, correctional institutions, and religious and fraternal organizations. Excluded from the sector are the goods-producing industries: manufacturing, agriculture, mining, forestry and fisheries, and construction.

387

Overview of Commercial Buildings, 2003 - Trends  

U.S. Energy Information Administration (EIA) Indexed Site

Trends in Commercial Buildings Sector-1979 to 2003 Trends in Commercial Buildings Sector-1979 to 2003 Since the first CBECS in 1979, the commercial buildings sector has increased in size. From 1979 to 2003: The number of commercial buildings increased from 3.8 million to 4.9 million (Figure 3). The amount of commercial floorspace increased from 51 billion to 72 billion square feet (Figure 4). Total energy consumed increased from less than 5,900 trillion to more than 6,500 trillion Btu (Figure 5). Electricity and natural gas consumption, nearly equal in 1979, diverged; electricity increased to more than 3,500 trillion Btu by 2003 while natural gas declined to 2,100 trillion Btu. Figure 3. The number of commercial buildings increased from 1979 to 2003. Figure 3. The number of commercial buildings increased from 1979 to 2003.

388

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Alternative Efficiency Determination Methods and Alternate Rating Methods Alternative Efficiency Determination Methods and Alternate Rating Methods Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) is proposing to revise and expand its existing regulations governing the use of alternative efficiency determination methods (AEDM) and alternate rating methods (ARM) for covered products as alternatives to testing for the purpose of certifying compliance. Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a final rule revising its existing regulations governing the use of particular methods as alternatives to testing for commercial heating, ventilating, air conditioning, water heating, and refrigeration equipment. 78 FR 79579 (December 31, 2013).

389

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Water Closets (Flush Toilets) Water Closets (Flush Toilets) Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of water closets (flush toilets) since 1992. Water closets (flush toilets) dispose of human waste by using water to flush it through a drainpipe to another location. The current standard will result in approximately $132.2 billion in savings for products shipped from 2007-2026. The Standards and Test Procedures for this product are related to Rulemaking for Plumbing Products Test Procedure. Recent Updates | Standards | Test Procedures | Waiver, Exception, and Exemption Information | Statutory Authority | Historical Information | Contact Information Recent Updates DOE published a final rule regarding test procedures for showerheads, faucets, water closets, urinals, and commercial prerinse spray valves. 78 FR 62970 (October 23, 2013). For more information, please see the rulemaking page.

390

commercial building | OpenEI  

Open Energy Info (EERE)

building building Dataset Summary Description Source EERE Date Released September 27th, 2010 (4 years ago) Date Updated September 27th, 2010 (4 years ago) Keywords buildings commercial building DOE energy use Data application/vnd.openxmlformats-officedocument.spreadsheetml.sheet icon New construction (xlsx, 391.9 KiB) application/vnd.openxmlformats-officedocument.spreadsheetml.sheet icon Post-1980 construction (in or after 1980) (xlsx, 391.9 KiB) application/vnd.openxmlformats-officedocument.spreadsheetml.sheet icon Pre-1980 construction (xlsx, 367.5 KiB) Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Time Period License License Open Data Commons Public Domain Dedication and Licence (PDDL) Comment Rate this dataset Usefulness of the metadata

391

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Illuminated Exit Signs Illuminated Exit Signs Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of illuminated exit signs since 2005. Illuminated exit signs are used to indicate exit doors in schools, hospitals, libraries, government buildings, and commercial buildings of all kinds, including offices, restaurants, stores, auditoriums, stadiums, and movie theatres. Recent Updates | Standards | Test Procedures | Waiver, Exception, and Exemption Information | Statutory Authority | Historical Information | Contact Information Recent Updates There are no recent updates for this equipment. Standards for Illuminated Exit Signs The following content summarizes the energy conservation standards for illuminated exit signs. The text is not an official reproduction of the Code of Federal Regulations and should not be used for legal research or citation.

392

SF6432-CS Commercial Services  

NLE Websites -- All DOE Office Websites (Extended Search)

7/31/13 7/31/13 Page 1 of 18 Printed copies of this document are uncontrolled. Retrieve latest version electronically. SANDIA CORPORATION SF 6432-CS (07/2013) SECTION II STANDARD TERMS AND CONDITIONS FOR COMMERCIAL SERVICES THE FOLLOWING CLAUSES APPLY TO THIS CONTRACT AS INDICATED UNLESS SPECIFICALLY DELETED, OR EXCEPT TO THE EXTENT THEY ARE SPECIFICALLY SUPPLEMENTED OR AMENDED IN WRITING IN THE COVER PAGE OR SECTION I. (CTRL+CLICK ON A LINK BELOW TO ADVANCE DIRECTLY TO THAT SECTION) ACCEPTANCE OF TERMS AND CONDITIONS (Ts&Cs) APPLICABLE LAW ASSIGNMENT BANKRUPTCY CANCELLATION OR TERMINATION FOR CONVENIENCE CHANGES COMPLIANCE WITH LAWS DEFINITIONS DISPUTES EXCUSABLE DELAYS EXPORT CONTROL ORDER OF PRECEDENCE PAYMENT PERFORMANCE EVALUATION PROGRAM

393

commercial buildings | OpenEI  

Open Energy Info (EERE)

buildings buildings Dataset Summary Description Emissions from energy use in buildings are usually estimated on an annual basis using annual average multipliers. Using annual numbers provides a reasonable estimation of emissions, but it provides no indication of the temporal nature of the emissions. Therefore, there is no way of understanding the impact on emissions from load shifting and peak shaving technologies such as thermal energy storage, on-site renewable energy, and demand control. Source NREL Date Released April 11th, 2011 (3 years ago) Date Updated April 11th, 2011 (3 years ago) Keywords buildings carbon dioxide emissions carbon footprinting CO2 commercial buildings electricity emission factors ERCOT hourly emission factors interconnect nitrogen oxides NOx SO2

394

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Faucets Faucets Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the water consumption level of faucets since 1992. This standard covers kitchen faucets and kitchen replacement aerators, lavatory faucets and lavatory replacement aerators, and metering faucets. These faucets are used widely in residential and commercial settings. The current standard will save approximately 0.9 quads of energy and result in approximately $25.2 billion in energy bill savings for products shipped from 1994-2013. The standard will avoid about 49.1 million metric tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of about 9.6 million automobiles. The Standards and Test Procedures for this product are related to Rulemaking for Plumbing Products Test Procedure.

395

Commercial laundry heat recovery system  

SciTech Connect

In a commercial laundry that is connected to a source of fresh water and generates heated waste water, a method is described for recovering heat from the heated waste comprising the steps of: (a) pumping the heated waste water through a heat exchanger; (b) introducing fresh water into the heat exchanger to receive heat from the waste water through a heat transfer effected by the heat exchanger; (c) withdrawing a first proportion of the heated fresh water at a first temperature; (d) conveying the first proportion of the heated fresh water to cold water storage tank; (e) withdrawing a second proportion of the heated fresh water at a second temperature higher than the first temperature; (f) conveying the second proportion of the heated fresh water to a hot water storage tank.

Kaufmann, R.O.

1986-07-29T23:59:59.000Z

396

Commercial laundry heat recovery system  

SciTech Connect

Waste water of above ambient temperature in a commercial laundry is directed through a self-cleaning plate and frame heat exchanger to heat incoming fresh water. Some of the fresh water heated to a first temperature is directed to a cold water storage tank to raise the water therein above ambient temperature which results in substantially lessened downstream requirements for heat input with commensurate cost reductions. The remainder of the fresh water is heated to a higher second temperature and is directed to a hot water storage tank. A system of valves regulates the temperature of the water flowing into each of the hot and cold water storage tanks to maintain a preset temperature in each of the storage tanks.

Kaufmann, R.O.

1983-02-15T23:59:59.000Z

397

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Room Air Conditioners Room Air Conditioners Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of residential room air conditioners since 1987. Residential room air conditioners are mounted in windows or through walls and deliver conditioned air to enclosed spaces. Room air conditioners typically extract heat from the room and vent it outdoors. These products are offered in a broad range of sizes and configurations. They are used in homes, apartments, and commercial settings. The standard implemented in 1990 will save approximately 0.7 quads of energy and result in approximately $8 billion in energy bill savings for products shipped from 1990-2019. The standard will avoid about 41.4 million metric tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of about 8.1 million automobiles.

398

Validating analysis methodologies used in burnup credit criticality calculations  

Science Conference Proceedings (OSTI)

The concept of allowing reactivity credit for the depleted (or burned) state of pressurized water reactor fuel in the licensing of spent fuel facilities introduces a new challenge to members of the nuclear criticality community. The primary difference in this analysis approach is the technical ability to calculate spent fuel compositions (or inventories) and to predict their effect on the system multiplication factor. Isotopic prediction codes are used routinely for in-core physics calculations and the prediction of radiation source terms for both thermal and shielding analyses, but represent an innovation for criticality specialists. This paper discusses two methodologies currently being developed to specifically evaluate isotopic composition and reactivity for the burnup credit concept. A comprehensive approach to benchmarking and validating the methods is also presented. This approach involves the analysis of commercial reactor critical data, fuel storage critical experiments, chemical assay isotopic data, and numerical benchmark calculations.

Brady, M.C. [Oak Ridge National Lab., TN (United States); Napolitano, D.G. [Yankee Atomic Electric Co., Boston, MA (United States)

1992-02-01T23:59:59.000Z

399

2013 completions of large solar thermal power plants mark ...  

U.S. Energy Information Administration (EIA)

Several large, new solar thermal power plants are expected to begin commercial operation by the end of 2013, more than doubling the solar thermal ...

400

Critical to Quality (CTQs)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Perfect Power Prototype at Perfect Power Prototype at Illinois Institute of Technology Progress Report November 2, 2010 Recipient: Illinois Institute of Technology Principal Investigator: Mohammad Shahidehpour 2 Project Overview  Funded by the U.S. Department of Energy  $12M ($7M from DOE, $5M Cost Share)  5 year project  Located at Illinois Institute of Technology (IIT)  Involves the entire campus  Partners: IIT, Exelon, S&C, Schweitzer, IPS 3 Project Objectives  50% peak demand reduction  20% permanent demand reduction  Demonstrate the value of Perfect Power  Cost avoidance and savings in outage costs  Deferral of planned substations  New products and commercialization  Replicable to larger cities  Promotion of energy efficiency and cleaner cities

Note: This page contains sample records for the topic "large commercial critical" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Critical Skills Master's Program  

NLE Websites -- All DOE Office Websites (Extended Search)

Skills Master's Program Skills Master's Program (CSMP): The Critical Skills Master's Program (CSMP) provides exceptional bachelor's-level candidates with the opportunity to pursue a fully funded Master's of Science degree. Successful applicants will become regular full-time Sandia employees and join multidisciplinary teams that are advancing the frontiers of science and technology to solve the world's greatest challenges. Program Requirements: * Apply to a minimum of 3 nationally accredited universities. * Successfully complete the GRE as required by the universities of interest. * Complete a master's degree within:

402

Impact of Fuel Failure on Criticality Safety of Used Nuclear Fuel  

SciTech Connect

Commercial used nuclear fuel (UNF) in the United States is expected to remain in storage for considerably longer periods than originally intended (e.g., <40 years). Extended storage (ES) time and irradiation of nuclear fuel to high-burnup values (>45 GWd/t) may increase the potential for fuel failure during normal and accident conditions involving storage and transportation. Fuel failure, depending on the severity, can result in changes to the geometric configuration of the fuel, which has safety and regulatory implications. The likelihood and extent of fuel reconfiguration and its impact on the safety of the UNF is not well understood. The objective of this work is to assess and quantify the impact of fuel reconfiguration due to fuel failure on criticality safety of UNF in storage and transportation casks. This effort is primarily motivated by concerns related to the potential for fuel degradation during ES periods and transportation following ES. The criticality analyses consider representative UNF designs and cask systems and a range of fuel enrichments, burnups, and cooling times. The various failed-fuel configurations considered are designed to bound the anticipated effects of individual rod and general cladding failure, fuel rod deformation, loss of neutron absorber materials, degradation of canister internals, and gross assembly failure. The results quantify the potential impact on criticality safety associated with fuel reconfiguration and may be used to guide future research, design, and regulatory activities. Although it can be concluded that the criticality safety impacts of fuel reconfiguration during transportation subsequent to ES are manageable, the results indicate that certain configurations can result in a large increase in the effective neutron multiplication factor, k{sub eff}. Future work to inform decision making relative to which configurations are credible, and therefore need to be considered in a safety evaluation, is recommended.

Marshall, William BJ J [ORNL; Wagner, John C [ORNL

2012-01-01T23:59:59.000Z

403

DRY TRANSFER FACILITY CRITICALITY SAFETY CALCULATIONS  

SciTech Connect

This design calculation updates the previous criticality evaluation for the fuel handling, transfer, and staging operations to be performed in the Dry Transfer Facility (DTF) including the remediation area. The purpose of the calculation is to demonstrate that operations performed in the DTF and RF meet the nuclear criticality safety design criteria specified in the ''Project Design Criteria (PDC) Document'' (BSC 2004 [DIRS 171599], Section 4.9.2.2), the nuclear facility safety requirement in ''Project Requirements Document'' (Canori and Leitner 2003 [DIRS 166275], p. 4-206), the functional/operational nuclear safety requirement in the ''Project Functional and Operational Requirements'' document (Curry 2004 [DIRS 170557], p. 75), and the functional nuclear criticality safety requirements described in the ''Dry Transfer Facility Description Document'' (BSC 2005 [DIRS 173737], p. 3-8). A description of the changes is as follows: (1) Update the supporting calculations for the various Category 1 and 2 event sequences as identified in the ''Categorization of Event Sequences for License Application'' (BSC 2005 [DIRS 171429], Section 7). (2) Update the criticality safety calculations for the DTF staging racks and the remediation pool to reflect the current design. This design calculation focuses on commercial spent nuclear fuel (SNF) assemblies, i.e., pressurized water reactor (PWR) and boiling water reactor (BWR) SNF. U.S. Department of Energy (DOE) Environmental Management (EM) owned SNF is evaluated in depth in the ''Canister Handling Facility Criticality Safety Calculations'' (BSC 2005 [DIRS 173284]) and is also applicable to DTF operations. Further, the design and safety analyses of the naval SNF canisters are the responsibility of the U.S. Department of the Navy (Naval Nuclear Propulsion Program) and will not be included in this document. Also, note that the results for the Monitored Geologic Repository (MGR) Site specific Cask (MSC) calculations are limited to the specific design chosen (see Assumption 3.4). A more current design will be included in the next revision of the criticality calculations for the Aging Facility. In addition, this calculation is valid for the current design as provided in Attachment III of the DTF and may not reflect the ongoing design evolution of the facility. However, it is anticipated that design changes to the facility layout will have little or no impact on the criticality results and/or conclusions presented in this document.

C.E. Sanders

2005-05-17T23:59:59.000Z

404

DOE/EM Criticality Safety Needs Assessment  

SciTech Connect

The issue of nuclear criticality safety (NCS) in Department of Energy Environmental Management (DOE/EM) fissionable material operations presents challenges because of the large quantities of material present in the facilities and equipment that are committed to storage and/or material conditioning and dispositioning processes. Given the uncertainty associated with the material and conditions for many DOE/EM fissionable material operations, ensuring safety while maintaining operational efficiency requires the application of the most-effective criticality safety practices. In turn, more-efficient implementation of these practices can be achieved if the best NCS technologies are utilized. In 2002, DOE/EM-1 commissioned a survey of criticality safety technical needs at the major EM sites. These needs were documented in the report Analysis of Nuclear Criticality Safety Technology Supporting the Environmental Management Program, issued May 2002. Subsequent to this study, EM safety management personnel made a commitment to applying the best and latest criticality safety technology, as described by the DOE Nuclear Criticality Safety Program (NCSP). Over the past 7 years, this commitment has enabled the transfer of several new technologies to EM operations. In 2008, it was decided to broaden the basis of the EM NCS needs assessment to include not only current needs for technologies but also NCS operational areas with potential for improvements in controls, analysis, and regulations. A series of NCS workshops has been conducted over the past years, and needs have been identified and addressed by EM staff and contractor personnel. These workshops were organized and conducted by the EM Criticality Safety Program Manager with administrative and technical support by staff at Oak Ridge National Laboratory (ORNL). This report records the progress made in identifying the needs, determining the approaches for addressing these needs, and assimilating new NCS technologies into EM fissionable material operations. In addition, the report includes projections of future EM needs and associted recommendations.

Westfall, Robert Michael [ORNL; Hopper, Calvin Mitchell [ORNL

2011-02-01T23:59:59.000Z

405

Plant critical concept  

SciTech Connect

The achievement of operation and maintenance (O&M) cost reductions is a prime concern for plant operators. Initiatives by the nuclear industry to address this concern are under way and/or in development. These efforts include plant reliability studies, reliability-centered maintenance, risk ranking and testing philosophies, performance-based testing philosophies, graded quality assurance, and so forth. This paper presents the results of an effort to develop a methodology that integrates and applies the common data and analysis requirements for a number of risk-based and performance-based initiatives. This initial phase of the effort applied the methodology and its results to two initiatives. These were the procurement function and the preventive maintenance function. This effort integrated multiple programs and functions to identify those components that are truly critical from an integrated plant performance perspective. The paper describes the scope of the effort, the development of a methodology to identify plant critical components, and the application of these results to the maintenance rule compliance, preventive maintenance, and procurement functions at the candidate plant.

O`Regan, P.J. [Yankee Atomic Electric Co., Bolton, MA (United States)

1995-12-31T23:59:59.000Z

406

Holyoke Gas and Electric - Commercial Energy Efficiency Loan...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Holyoke Gas and Electric - Commercial Energy Efficiency Loan Program Holyoke Gas and Electric - Commercial Energy Efficiency Loan Program Eligibility Commercial Industrial...

407

Columbia Water & Light - Commercial Super Saver Loans | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial Super Saver Loans Columbia Water & Light - Commercial Super Saver Loans Eligibility Commercial Fed. Government Industrial Nonprofit State Government Savings For Heating...

408

City Water Light and Power - Commercial Energy Efficiency Rebate...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Water Light and Power - Commercial Energy Efficiency Rebate Programs City Water Light and Power - Commercial Energy Efficiency Rebate Programs Eligibility Commercial Nonprofit...

409

Commercial Clean Energy Grant Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Marketing Administration Other Agencies You are here Home Savings Commercial Clean Energy Grant Program Commercial Clean Energy Grant Program Eligibility Commercial...

410

Montana-Dakota Utilities (Gas) - Commercial Natural Gas Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial Natural Gas Efficiency Rebate Program Montana-Dakota Utilities (Gas) - Commercial Natural Gas Efficiency Rebate Program Eligibility Commercial Savings For Other Heating...

411

TECHNOLOGY TRANSFER COMMERCIALIZATION ACT OF 2000 PDF | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

TECHNOLOGY TRANSFER COMMERCIALIZATION ACT OF 2000 PDF TECHNOLOGY TRANSFER COMMERCIALIZATION ACT OF 2000 PDF TECHNOLOGY TRANSFER COMMERCIALIZATION ACT OF 2000 PDF TECHNOLOGY...

412

Ohio Valley Gas Corporation - Residential and Small Commercial...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial Natural Gas Incentive Program Ohio Valley Gas Corporation - Residential and Small Commercial Natural Gas Incentive Program Eligibility Commercial Residential Savings...

413

Critical infrastructure security curriculum modules  

Science Conference Proceedings (OSTI)

Critical infrastructures have succumbed to the demands of greater connectivity. Although the scheme of connecting these critical equipment and devices to cyberspace has brought us tremendous convenience, it also enabled certain unimaginable risks and ... Keywords: SCADA, control systems, course modules, critical infrastructures, cybersecurity, programmable logic controllers, security, vulnerability

Guillermo A. Francia, III

2011-09-01T23:59:59.000Z

414

Computers in Commercial Buildings - Table 4  

U.S. Energy Information Administration (EIA) Indexed Site

4 4 Table 4. Percent Change in the Number of Computers in Commercial Buildings, 1992 to 1999 Percent Change in Number of Computers Percent Change in Computers per Thousand Employees Percent Change in Computers per Million Square Feet 1992 to 1995 1995 to 1999 1992 to 1995 1995 to 1999 1992 to 1995 1995 to 1999 All Buildings 45 35 32 24 58 17 Principal Building Activity Assembly* 109 -6 54 104 157 44 Education 34 48 -3 58 46 33 Food Sales 142 20 213 -20 184 -22 Food Service 89 102 82 17 108 48 Health Care 126 43 70 3 70 15 Lodging 99 45 47 69 59 16 Mercantile and Service 62 25 96 107 57 147 Office 37 31 33 20 53 14 Large (>50,000 Sq. Ft.) 37 31 24 16 52 3 Small (<=50,000 Sq. Ft.) 37 30 48 26 55 28 Warehouse and Storage 24 43 4 13 58 16 Other (incl. Vacant) 24 44 -15 462 54 364  * The category "assembly" is equivalent to the "public assembly" category used in the 1999 tables and figures.

415

Effect of Strain on the Critical Current and Flux Pinning in ...  

Science Conference Proceedings (OSTI)

Abstract Scope, Strain can have a large effect on the critical current density (Jc) of high-temperature superconductors (HTS), even before the superconductor is...

416

Hutchinson Utilities Commission - Commercial Energy Efficiency Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Hutchinson Utilities Commission - Commercial Energy Efficiency Hutchinson Utilities Commission - Commercial Energy Efficiency Program Hutchinson Utilities Commission - Commercial Energy Efficiency Program < Back Eligibility Commercial Fed. Government Local Government Nonprofit State Government Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Other Heat Pumps Commercial Lighting Lighting Manufacturing Maximum Rebate $2,000 Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount Lighting: $300 per kW saved LED Exit Signs: $12 Occupancy Sensors: $20 - $40 Air Conditioning Systems: $20 - $40 per ton Air-Source Heat Pumps: $65 - $150 per ton Geothermal Heat Pumps: $150 per ton Chillers: $3,000 - $4,000, depending on size Chilled Water Resets: $350 - $900, depending on type and size

417

Pedernales Electric Cooperative - Commercial Lighting Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Pedernales Electric Cooperative - Commercial Lighting Rebate Pedernales Electric Cooperative - Commercial Lighting Rebate Program Pedernales Electric Cooperative - Commercial Lighting Rebate Program < Back Eligibility Commercial Savings Category Other Appliances & Electronics Commercial Lighting Lighting Program Info Expiration Date Installation must be made within one year of the preliminary approval date State Texas Program Type Utility Rebate Program Rebate Amount 20-29 kW saved: $75/kW new; $150/kW retrofit 30-39 kW saved: $100/kW new; $200/kW retrofit 40-49 kW saved: $125/kW new; $250/kW retrofit 50 or more kW saved: $150/kW new; $300/kW retrofit Provider Conservation Section For existing and new commercial construction, Pedernales Electric Cooperative provides incentives for kW saved through efficient lighting.

418

Building Technologies Office: Commercial Building Research  

NLE Websites -- All DOE Office Websites (Extended Search)

to someone by E-mail to someone by E-mail Share Building Technologies Office: Commercial Building Research on Facebook Tweet about Building Technologies Office: Commercial Building Research on Twitter Bookmark Building Technologies Office: Commercial Building Research on Google Bookmark Building Technologies Office: Commercial Building Research on Delicious Rank Building Technologies Office: Commercial Building Research on Digg Find More places to share Building Technologies Office: Commercial Building Research on AddThis.com... About Take Action to Save Energy Activities 179d Tax Calculator Advanced Energy Design Guides Advanced Energy Retrofit Guides Building Energy Data Exchange Specification Buildings Performance Database Data Centers Energy Asset Score Energy Modeling Software Global Superior Energy Performance Partnership

419

NYSEG (Electric) - Commercial and Industrial Efficiency Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial and Industrial Efficiency Program Commercial and Industrial Efficiency Program NYSEG (Electric) - Commercial and Industrial Efficiency Program < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit State Government Tribal Government Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Other Heat Pumps Appliances & Electronics Commercial Lighting Lighting Maximum Rebate No maximum per customer rebate; however, NYSEG/RG&E reserve the right to cap the rebate to any one customer. Program Info State New York Program Type Utility Rebate Program Rebate Amount Lighting, HVAC: Prescriptive incentives vary A/C or Heat Pump A/C or Heat Pump > 63 tons: $25/ton + $5/ton for each 0.1 EER above 9.7 Water Cooled Chillers: $6/ton or $15/ton + $2-$8/ton for each 0.01 kW/ton

420

Western Massachusetts Electric - Commercial Energy Efficiency Rebates |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Western Massachusetts Electric - Commercial Energy Efficiency Western Massachusetts Electric - Commercial Energy Efficiency Rebates Western Massachusetts Electric - Commercial Energy Efficiency Rebates < Back Eligibility Commercial Industrial Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Manufacturing Other Heating Heat Pumps Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Pre-approval required for rebates greater than $5,000 Program Info State Massachusetts Program Type Utility Rebate Program Rebate Amount Small Business Program: up to 70% of cost, zero percent financing on remainder Custom: based on energy savings Retrofit Pay-for-Performance Incentive: $0.75/kWh or therm saved Lighting: Varies, see program web site Vending Machine Controls: $45 - $115 Variable Speed Drive (Retrofit): $2,550 - $10,500

Note: This page contains sample records for the topic "large commercial critical" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Participation through Automation: Fully Automated Critical Peak Pricing in Commercial Buildings  

E-Print Network (OSTI)

to 1.95 W ft, with maximum demand reductions 0.21 to 4.68and the non-coincident maximum demand savings. W e do notstrategies. Table 4. Maximum Demand Response for all Seven

Piette, Mary Ann; Watson, David S.; Motegi, Naoya; Kiliccote, Sila; Linkugel, Eric

2006-01-01T23:59:59.000Z

422

Participation through Automation: Fully Automated Critical Peak Pricing in Commercial Buildings  

E-Print Network (OSTI)

2004. Working Group 2 Demand Response Evaluation Program2006. Au tomated Demand Response Control Strategies inrequired. Figure 2. Demand Response Automation Server and

Piette, Mary Ann; Watson, David S.; Motegi, Naoya; Kiliccote, Sila; Linkugel, Eric

2006-01-01T23:59:59.000Z

423

Critical CRBR core pressure  

Science Conference Proceedings (OSTI)

The conditions are detailed under which gas pressure will cause or initiate failure in the structural containment of the fuel core. The Clinch River Breeder Reactor Plant is the prototype structure. Two general classes of problems have been studied, representing two entirely distinct configurations of containment failure. The first model determines the minimum pressure to lift a portion or the entire core from its containment. The second model estimates the critical pressure above which the fuel rods interior to the hexagonal fuel can warp, leading to blockage of the gas passages. Such blockage might cause further buildup of the gas pressure to a level causing the failure of the fuel rod containment in the hexagonal fuel container.

Ju, F.D.

1980-06-01T23:59:59.000Z

424

Critical challenges for EUV resist materials  

SciTech Connect

Although Extreme ultraviolet lithography (EUVL) is now well into the commercialization phase, critical challenges remain in the development of EUV resist materials. The major issue for the 22-nm half-pitch node remains simultaneously meeting resolution, line-edge roughness (LER), and sensitivity requirements. Although several materials have met the resolution requirements, LER and sensitivity remain a challenge. As we move beyond the 22-nm node, however, even resolution remains a significant challenge. Chemically amplified resists have yet to demonstrate the required resolution at any speed or LER for 16-nm half pitch and below. Going to non-chemically amplified resists, however, 16-nm resolution has been achieved with a LER of 2 nm but a sensitivity of only 70 mJ/cm{sup 2}.

Naulleau, Patrick P.; Anderson, Christopher N.; Baclea-an, Lorie-Mae; Denham, Paul; George, Simi; Goldberg, Kenneth A.; Jones, Gideon; McClinton, Brittany; Miyakawa, Ryan; Rekawa, Seno; Smith, Nathan

2011-02-28T23:59:59.000Z

425

Commercial Building Activities | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Building Activities Building Activities Commercial Building Activities The Building Technologies Office commercial buildings effort researches and deploys advanced technologies and systems to reduce energy consumption in commercial buildings. Industry partners and national laboratories help identify market needs and solutions to accelerate the development of highly energy-efficient buildings. This page outlines some of BTO's key projects. 179d Tax Calculator The 179d Calculator can help determine whether improvements qualify for a Federal tax deduction, and allows owners and managers to estimate energy cost savings of efficiency improvements. Advanced Energy Design Guides These recommendations can help designers achieve between 30% and 50% energy savings in a new commercial building.

426

Sharyland Utilities- Commercial Standard Offer Program (Texas)  

Energy.gov (U.S. Department of Energy (DOE))

Sharyland Utilities offers its Commercial Standard Offer Program to encourage business customers of all sizes to pursue energy efficiency measures in their facilities. Incentives are paid directly...

427

Solar Heated Pools for Your Commercial Property  

SciTech Connect

A brochure describing the energy-saving and cost-saving benefits of using solar water heating in commercial swimming pools.

American Solar Energy Society

2001-06-19T23:59:59.000Z

428

Shakopee Public Utilities - Commercial and Industrial Energy...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Single Packaged Air Conditioning (including Rooftop Units): 50 - 65 Shakopee Public Utilities (SPU) offers a wide array of rebates and incentives encouraging its commercial...

429

Innovation Ecosystem Initiative - EERE Commercialization Office  

Innovation Ecosystem Initiative. In September 2010, the Department of Energy's (DOE) Office of Energy Efficiency and Renewable Energy (EERE) Commercialization Team ...

430

Commercial and Industrial Prescriptive Rebates | Open Energy...  

Open Energy Info (EERE)

Heat pumps, Lighting, Lighting ControlsSensors, Motor VFDs, Refrigerators, Roofs, LED Exit Signs, Commercial Refrigeration Equipment, Food Service Equipment, Room Air...

431

Avista Utilities (Electric) - Commercial Lighting Energy Efficiency...  

Open Energy Info (EERE)

Applicable Sector Commercial Eligible Technologies Lighting, Lighting ControlsSensors, LED Lighting Active Incentive Yes Implementing Sector Utility Energy Category Energy...

432

Baltimore Gas & Electric Company (Electric) - Commercial Energy...  

Open Energy Info (EERE)

Vending Machine Controls, Commercial Refrigeration Equipment, Food Service Equipment, LED Lighting, Reach-In Door Closer, ECM Evaporator Fan MotorController, Refrigerated...

433

Coldwater Board of Public Utilities - Commercial & Industrial...  

Open Energy Info (EERE)

CustomOthers pending approval, Lighting, Lighting ControlsSensors, Motor VFDs, Motors, LED Exit Signs, Vending Machine Controls, Commercial Refrigeration Equipment, Food Service...

434

Partnership Requirements: ENERGY STAR Partnership for Commercial...  

NLE Websites -- All DOE Office Websites (Extended Search)

Partnership Requirements: ENERGY STAR Partnership for Commercial & Industrial Service and Product Providers (SPP) Secondary menu About us Press room Contact Us Portfolio Manager...

435

Energy Information Administration (EIA)- Commercial Buildings ...  

U.S. Energy Information Administration (EIA)

Energy use in homes, commercial buildings, manufacturing, and transportation. Coal. ... we will request energy use and cost data ... social workers , interior ...

436

Energy Information Administration (EIA)- Commercial Buildings ...  

U.S. Energy Information Administration (EIA)

Laboratory: 25: 455: 108: 203: Lodging: 158: 3,618: 461: 839 ... Source: 1995 Commercial Buildings Energy Consumption Survey Energy Information Administration.

437

Compliance Verification Paths for Residential and Commercial...  

NLE Websites -- All DOE Office Websites (Extended Search)

Verification Paths for Residential and Commercial Energy Codes Conformity assessment is a term used to describe the processes followed to demonstrate that a product, service,...

438

Automated Continuous Commissioning of Commercial Buildings  

E-Print Network (OSTI)

Conference on Building Commissioning. San Francisco, CA. 17.Commercial Buildings Commissioning, LBNL- 56637, Nov. 2004.Automated Continuous Commissioning Tool GUI Screenshots from

Bailey, Trevor

2013-01-01T23:59:59.000Z

439

Technology Commercialization and Partnerships | Brookhaven Lab ...  

'Agreements for Commercializing Technology' (ACT) Now Available. Lab and DOE staff who worked on the ACT project include, ... Media & Communications Office.

440

American Municipal Power (Public Electric Utilities) - Commercial...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2011, is funded and supported by 49 member communities. All residential, commercial, and industrial customers of communities that have subscribed to Efficiency Smart are eligible...

Note: This page contains sample records for the topic "large commercial critical" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Avista Utilities (Electric) - Commercial Energy Efficiency Incentives...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

kWh saved in first year Avista Utilities offers numerous incentives to commercial and industrial customers to increase the energy efficiency of customer facilities or...

442

Building Technologies Office: Commercial Building Research and...  

NLE Websites -- All DOE Office Websites (Extended Search)

Tax Incentives for Residential Buildings Tax Incentives for Commercial Buildings News Energy Department Invests in Heating, Cooling, and Lighting August 21, 2013 Energy Department...

443

Energy Information Administration - Commercial Energy Consumption...  

Annual Energy Outlook 2012 (EIA)

to totals. Source: Energy Information Administration, Office of Energy Markets and End Use, Forms EIA-871A, C, and E of the 2003 Commercial Buildings Energy Consumption Survey....

444

Energy Information Administration - Commercial Energy Consumption...  

Gasoline and Diesel Fuel Update (EIA)

may not sum to totals. Source: Energy Information Administration, Office of Energy Markets and End Use, Form EIA-871A of the 2003 Commercial Buildings Energy Consumption Survey....

445

NETL: Advanced Research - Pathways to Commercial Applications  

NLE Websites -- All DOE Office Websites (Extended Search)

Research Pathways to Commercial Applications CHALLENGE: Separating H2 and CO2 Pilot plant pyrolysis unit with biomass feedstack system. Pilot plant pyrolysis unit with biomass...

446

U.S. Commercial Buildings Energy Intensity  

U.S. Energy Information Administration (EIA)

Energy Efficiency > Commercial Buildings Energy Intensities > Table 6b . ... Warehouse and Storage 42: 38 45: Other: 3. 154: 170 163: Vacant 28: 21 21: Total ...

447

Vermont Gas- Commercial Energy Efficiency Program  

Energy.gov (U.S. Department of Energy (DOE))

Vermont Gas (VGS) offers two energy efficiency programs for commercial customers: the WorkPlace New Construction Program and the WorkPlace Equipment Replacement and Retrofit Program.

448

Energy Efficiency Fund (Electric) - Commercial and Industrial...  

Open Energy Info (EERE)

Comprehensive MeasuresWhole Building, Compressed air, CustomOthers pending approval, Energy Mgmt. SystemsBuilding Controls, Programmable Thermostats, Windows, Commercial...

449

Citizens Gas - Commercial Efficiency Rebates (Indiana) | Open...  

Open Energy Info (EERE)

Sector Commercial Eligible Technologies Boilers, CustomOthers pending approval, Energy Mgmt. SystemsBuilding Controls, Furnaces, Programmable Thermostats, Steam-system...

450

Nicor Gas - Commercial Energy Efficiency Rebates (Illinois) ...  

Open Energy Info (EERE)

Sector Commercial Eligible Technologies Boilers, CustomOthers pending approval, Energy Mgmt. SystemsBuilding Controls, Furnaces, Steam-system upgrades, Water Heaters,...

451

Building Technologies Office: About the Commercial Buildings...  

NLE Websites -- All DOE Office Websites (Extended Search)

and others to implement real-world energy saving opportunities. Commercial Building Basics Federal, state, and local governments as well as private companies, own, operate...

452

Saving Electrical Energy in Commercial Buildings.  

E-Print Network (OSTI)

??With the commercial and institutional building sectors using approximately 29% and 34% of all electrical energy consumption in Canada and the United States, respectively, saving (more)

Case, Ryan

2012-01-01T23:59:59.000Z

453

Commercial Buildings Characteristics 1995 - Index Page  

U.S. Energy Information Administration (EIA) Indexed Site

>Commercial Buildings Home > 1995 Characteristics Data 1995 Data Executive Summary Table of Contents Overview to Detailed Tables Detailed Tables 1995 national and Census region...

454

Kenergy- Commercial and Industrial Rebate Program  

Energy.gov (U.S. Department of Energy (DOE))

Kenergy offers commercial and industrial customers rebates for energy-efficient lighting and other energy efficient improvements. Customers can receive rebates of $350 per kilowatt of energy...

455

Specifying Fenestration Products for Commercial Buildings  

NLE Websites -- All DOE Office Websites (Extended Search)

brochure which explains how this relatively new and low-cost technology can reduce cooling loads in commercial buildings without any loss in visible light or change in...

456

U.S. Commercial Buildings Energy Intensity  

U.S. Energy Information Administration (EIA)

Table 7c. U.S. Commercial Buildings Energy Intensity Using Primary Energy 1 by Census Region and Principal Building Activity, 1992-1999 (Million Btu per Worker)

457

Avista Utilities - Commercial Lighting Energy Efficiency Program...  

Open Energy Info (EERE)

Share this page on Facebook icon Twitter icon Avista Utilities - Commercial Lighting Energy Efficiency Program (Idaho) This is the approved revision of this page, as well...

458

Golden Valley Electric Association - Commercial Lighting Retrofit...  

Open Energy Info (EERE)

on Facebook icon Twitter icon Golden Valley Electric Association - Commercial Lighting Retrofit Rebate Program (Alaska) This is the approved revision of this page, as well...

459

Central Hudson Gas & Electric (Electric) - Commercial Lighting...  

Open Energy Info (EERE)

icon Twitter icon Central Hudson Gas & Electric (Electric) - Commercial Lighting Rebate Program (New York) This is the approved revision of this page, as well as...

460

Barron Electric Cooperative - Commercial and Industry Energy...  

Open Energy Info (EERE)

icon Barron Electric Cooperative - Commercial and Industry Energy Efficiency Lighting Rebates (Wisconsin) This is the approved revision of this page, as well as being the...

Note: This page contains sample records for the topic "large commercial critical" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Detroit Public Lighting Department - Commercial and Industrial...  

Open Energy Info (EERE)

with form History Share this page on Facebook icon Twitter icon Detroit Public Lighting Department - Commercial and Industrial Energy Wise Program This is the approved...

462

Colton Public Utilities - Commercial Lighting Rebate Program...  

Open Energy Info (EERE)

this page on Facebook icon Twitter icon Colton Public Utilities - Commercial Lighting Rebate Program (California) This is the approved revision of this page, as well as...

463

Guidelines for the Competition - EERE Commercialization Office  

Search Help Commercialization ... Business plan teams may enter multiple ... The following items will be further clarified in the official Terms & Conditions and the ...

464

Barron Electric Cooperative - Commercial, Industrial, and Agricultural...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lighting: 15fixture LED Exit Sign: 5sign Occupancy Sensors: 5switch Commercial Air Conditioning Units: 40ton Plate CoolersPre-Coolers: 500unit Dairy Refrigeration...

465

Commercial Refrigeration Equipment | Open Energy Information  

Open Energy Info (EERE)

Refrigeration Equipment Jump to: navigation, search TODO: Add description List of Commercial Refrigeration Equipment Incentives Retrieved from "http:en.openei.orgw...

466

KIUC- Energy Wise Commercial Energy Efficiency Program  

Energy.gov (U.S. Department of Energy (DOE))

Kauai Island Utility Cooperative, a Touchstone Energy Cooperative, offers incentives to its commercial customers for installing energy efficient equipment. The eligible replacements are identified...

467

Dakota Electric Association - Commercial and Industrial Energy...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Heating & Cooling Cooling Other Heat Pumps Appliances & Electronics Commercial Lighting Lighting Manufacturing Water Heating Maximum Rebate 100,000 Building Measures: 50%...

468

Southwest Gas Corporation - Commercial Energy Efficient Equipment...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

offers rebates to commercial customers in Nevada who purchase energy efficient natural gas equipment. Eligible equipment includes clothes washers, storage water heaters, tankless...

469

Longmont Power & Communications - Residential and Commercial...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

& Electronics Maximum Rebate 50 per appliance. Residential: 1 clothes washer and 1 dishwasher per year Commercial: 3 clothes washers and 3 dishwashers per year Program...

470

Connexus Energy- Commercial Energy Efficiency Rebate Programs  

Energy.gov (U.S. Department of Energy (DOE))

Connexus Energy provides rebates to commercial, industrial and agricultural customers in order to encourage energy efficiency. Business customers are eligible for free energy evaluations and a...

471

Lake Region Electric Cooperative - Commercial Energy Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

details Lake Region Electric Cooperative (LREC) offers grants to commercial customers for electric energy efficiency improvements, audits, and engineering and design assistance for...

472

Commercial Buildings Energy Consumption and Expenditures 1992  

Annual Energy Outlook 2012 (EIA)

(92) Distribution Category UC-950 Commercial Buildings Energy Consumption and Expenditures 1992 April 1995 Contacts The Energy Information Administration (EIA) prepared this...

473

Renewable Energy Project Development and Financing: Commercial...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

and to Whom Course Outline What we will cover... About the DOE Office of Indian Energy Education Initiative Commercial-Scale Process: Hypothetical Example - Project...

474

Commercialization and Licensing | ornl.gov  

NLE Websites -- All DOE Office Websites (Extended Search)

Exclusive Patent License for ORNL Graphite Foam Technology January 28, 2010 - Light-emitting diode (LED) lamps are increasingly in demand in industrial and commercial...

475

Santee Cooper- Commercial Energy Efficiency Rebate Program  

Energy.gov (U.S. Department of Energy (DOE))

Santee Cooper, through its Reduce The Use program, provides rebates to commercial customers for the purchase and installation of energy efficient equipment and measures. Rebates are available on...

476

Training the Next Generation of Commercial Building ...  

Science Conference Proceedings (OSTI)

... tools, building energy codes and appliance standards. ... automation system (BAS) and small-to-medium ... intended to apply to smaller commercial and ...

2012-09-20T23:59:59.000Z

477

Technology Commercialization and Partnerships | Long Island ...  

Jordan Darrow Darrow Associates, Inc. (631) 367-1866 jdarrow@darrowir.com. Tags: commercial. 2012-1429 | Media & Communications Office. In other news...

478

NETL: Gasification - Development of Prototype Commercial Gasifier...  

NLE Websites -- All DOE Office Websites (Extended Search)

Development of Prototype Commercial Gasifier Sensor Gas Technology Institute Project Number: FE0008350 Project Description Gas Technology Institute (GTI) is developing a reliable,...

479

Piedmont Natural Gas- Commercial Equipment Efficiency Program  

Energy.gov (U.S. Department of Energy (DOE))

Piedmont Natural Gas offers rebates to commercial customers for purchasing and installing high-efficiency natural gas tankless water heaters. Customers on the 202-Small General Service Standard...

480

Empire District Electric - Commercial and Industrial Energy Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Empire District Electric - Commercial and Industrial Energy Efficiency Rebates Empire District Electric - Commercial and Industrial Energy Efficiency Rebates < Back Eligibility...

Note: This page contains sample records for the topic "large commercial critical" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Cheyenne Light, Fuel and Power (Electric) - Commercial Energy...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

- Commercial Energy Efficiency Rebate Program (Wyoming) Cheyenne Light, Fuel and Power (Electric) - Commercial Energy Efficiency Rebate Program (Wyoming) < Back...

482

Duke Energy (Electric) - Commercial and Industrial Energy Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

(Electric) - Commercial and Industrial Energy Efficiency Rebate Program Duke Energy (Electric) - Commercial and Industrial Energy Efficiency Rebate Program < Back Eligibility...

483

Energy Smart - Commercial and Industrial Energy Efficiency Rebate...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Efficiency Rebate Program (20 Municipalities) < Back Eligibility Commercial Industrial Savings Category Heating & Cooling Commercial Heating & Cooling Cooling...

484

Otter Tail Power Company - Commercial and Industrial Energy Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Industrial Energy Efficiency Rebate Program < Back Eligibility Agricultural Commercial Industrial Savings Category Home Weatherization Commercial Weatherization Heating &...

485

ENERGY STAR Commercial Buildings College Course: Week 4 Sample...  

NLE Websites -- All DOE Office Websites (Extended Search)

and product providers Verify applications for ENERGY STAR certification Design commercial buildings Energy efficiency program administrators Commercial and industrial program...

486

ENERGY STAR Commercial Buildings College Course | ENERGY STAR  

NLE Websites -- All DOE Office Websites (Extended Search)

and product providers Verify applications for ENERGY STAR certification Design commercial buildings Energy efficiency program administrators Commercial and industrial program...

487

ENERGY STAR Commercial Buildings College Course: About the Course...  

NLE Websites -- All DOE Office Websites (Extended Search)

and product providers Verify applications for ENERGY STAR certification Design commercial buildings Energy efficiency program administrators Commercial and industrial program...

488

ENERGY STAR Commercial Buildings College Course: Week 3 Sample...  

NLE Websites -- All DOE Office Websites (Extended Search)

and product providers Verify applications for ENERGY STAR certification Design commercial buildings Energy efficiency program administrators Commercial and industrial program...

489

Energy Efficiency Standards for Residential and Commercial Equipment...  

NLE Websites -- All DOE Office Websites (Extended Search)

Standards for Residential and Commercial Equipment: Additional Opportunities Title Energy Efficiency Standards for Residential and Commercial Equipment: Additional...

490

U.S. Commercial Buildings Weather-Adjusted Site Energy  

U.S. Energy Information Administration (EIA)

Energy Efficiency > Commercial Buildings Energy Intensities > Table 1b . U.S. Commercial Buildings Weather-Adjusted Site Energy

491

Otter Tail Power Company - Commercial & Industrial Energy Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Cooling Commercial Heating & Cooling Cooling Heating Heat Pumps Appliances & Electronics Commercial Lighting Lighting Manufacturing Water Heating Maximum Rebate Refrigeration...

492

Cape Light Compact - Commercial, Industrial and Municipal Buildings...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Manufacturing Other Construction Heat Pumps Appliances & Electronics Commercial Lighting Lighting Commercial Weatherization Water Heating Maximum Rebate Retrofit: 50% of cost...

493

Kansas City Power and Light - Commercial/Industrial Energy Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial Heating & Cooling Cooling Other Appliances & Electronics Commercial Lighting Lighting Manufacturing Maximum Rebate Maximum custom incentive amount varies from...

494

Chlorofluorocarbon environmental issues related to conservation acquisition in commercial buildings  

SciTech Connect

Recent scientific evidence strongly suggests that the release of large quantities of chlorofluorocarbon (CFC) gases into the atmosphere will result in environmentally harmful long-term effects. Because of those effects, a massive worldwide effort is currently under way to ban their use. At request of the Bonneville Power Administration, the Pacific Northwest Laboratory conducted a literature search to identify the issues surrounding the CFC phaseout. The search was focused on how these issues impact the commercial building sector. Information was obtained that describes: How the release of CFCs into the atmosphere may affect the global environment; legislative and regulatory programs initiated to restrict CFCs; potential impacts the reduced CFC supply will have on commercial buildings; the most promising CFC substitute technologies; and the potential costs of CFC restriction. 11 refs., 2 tabs.

Marseille, T.J.; Baechler, M.C.

1990-09-01T23:59:59.000Z

495

Commercial Building Energy Asset Score Features | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Score Score Features Commercial Building Energy Asset Score Features The Asset Scoring Tool evaluates buildings by use type. The initial version of the Asset Scoring Tool included: office, school, retail, and unrefrigerated warehouse buildings. Phase II currently under development, which will be used for the 2013 Pilot, includes library, lodging, multi-family housing, and courthouse buildings, as well as mixed-use types of buildings that incorporate Phase I and II. You can enter small and large commercial buildings, and an Asset Score will be equally applicable to new and existing buildings. Inputs You can enter these building characteristics: General information-number of floors, footprint dimension, orientation, and use type Envelope components-roof, exterior wall, and floor types and

496

Large-Eddy Simulation: How Large is Large Enough?  

Science Conference Proceedings (OSTI)

The length scale evolution of various quantities in a clear convective boundary layer (CBL), a stratocumulus-topped boundary layer, and three radiatively cooled (smoke cloud) convective boundary layers are studied by means of large-eddy ...

Stephan R. de Roode; Peter G. Duynkerke; Harm J. J. Jonker

2004-02-01T23:59:59.000Z

497

Commercial Reference Buildings | Open Energy Information  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon » Commercial Reference Buildings Jump to: navigation, search DOE developed Commercial Reference Buildings which provide descriptions for whole building analysis using EnergyPlus. There are 16 building types and three categories that apply to all building types. The commercial reference buildings were developed across 16 reference locations. Contents 1 Building Types 2 Construction Categories 3 Climate Zones Used to Create Reference Buildings 4 References Building Types DOE developed 16 Commercial Reference Building Types[1] , which represent approximately 70% of the commercial buildings in the U.S. [2]. Whole

498

Small Commercial Refrigeration Incentive | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Small Commercial Refrigeration Incentive Small Commercial Refrigeration Incentive Small Commercial Refrigeration Incentive < Back Eligibility Agricultural Commercial Industrial Institutional Nonprofit Savings Category Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Incentives over $5,000 must be pre-approved Program Info Funding Source Efficiency Vermont Public Benefit Fund Expiration Date 06/30/2013 State Vermont Program Type State Rebate Program Rebate Amount Outside Air Economizers: $1,250 Evaporator Fan Motors: $20 - $100 Evaporator Fan Motor Controls: $550 Door/Frame Heater Controls: $50 per door Case Light Occupancy Controls: $40 LED Refrigerator and Freezer Case Light Fixtures: $6 - $15 per foot Energy Star Ice Machines: $50 - $75 Efficient Compressors: $200 Display Case Strip-Curtain and Continuous Covers: $6 per foot

499

Nuclear Criticality Safety - Nuclear Engineering Division (Argonne...  

NLE Websites -- All DOE Office Websites (Extended Search)

Criticality Safety Nuclear Criticality Safety Overview Experience Analysis Tools Current NCS Activities Current R&D Activities DOE Criticality Safety Support Group (CSSG) Other...

500

MCNP/KENO criticality benchmarks  

SciTech Connect

In the past, criticality safety analyses related to the handling and storage of fissile materials were obtained from critical experiments, nuclear safety guides, and handbooks. As a result of rising costs and time delays associated with critical experiments, most experimental facilities have been closed, triggering an increased reliance on computational methods. With this reliance comes the need and requirement for redundant validation by independent criticality codes. Currently, the KENO Monte Carlo transport code is the most widely used tool for criticality safety calculations. For other transport codes, such as MCNP, to be accepted by the criticality safety community as a redundant validation tool they must be able to reproduce experimental results at least as well as KENO. The Monte Carlo neutron, photon, and electron transport code MCNP, has an extensive list of attractive features, including continuous energy cross sections, generalized 3-D geometry, time dependent transport, criticality k{sub eff} calculations, and comprehensive source and tally capabilities. It is widely used for nuclear criticality analysis, nuclear reactor shielding, oil well logging, and medical dosimetry calculations. This report specifically addresses criticality and benchmarks the KENO 25 problem test set. These sample problems constitute the KENO standard benchmark set and represent a relatively wide variety of criticality problems. The KENO Monte Carlo code was chosen because of its extensive benchmarking against analytical and experimental criticality results. Whereas the uncertainty in experimental parameters generally prohibits code validation to better than about 1% in k{sub eff}, the value of k{sub eff} for criticality is considered unacceptable if it deviates more than a few percent from measurements.

McKinney, G.W. [Los Alamos National Lab., NM (United States); Wagner, J.C. [Pennsylvania State Univ., University Park, PA (United States); Sisolak, J.E. [Wisconsin Univ., Madison, WI (United States)

1993-04-01T23:59:59.000Z