Powered by Deep Web Technologies
Note: This page contains sample records for the topic "lamp type standard" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

The effects of fixture type and HVAC integration on fluorescent lamp/ballast performance  

SciTech Connect

This paper describes the effects of fixture type and lamp compartment air extract characteristics on lamp/ballast performance. A luminaire/plenum/HVAC simulator was used to measure minimum lamp wall temperature inside four fixture types while varying lamp-compartment extract conditions. Experimental data show that the lumen output of the lamp/ballast system varies by 20% and system efficacy by 10%, depending on the type of fixture and lamp-compartment extract technique employed.

Siminovitch, M.J.; Rubinstein, F.M.; Verderber, R.R.; Clark, T.A.

1986-06-01T23:59:59.000Z

2

Guidance Concerning Enforcement of EISA 2007 Standards Candelabra Base and Intermediate Base Lamps  

Energy.gov (U.S. Department of Energy (DOE))

The Energy Independence and Security Act of 2007 (EISA 2007) imposed energy conservation standards for candelabra and intermediate base lamps, and those provisions became effective with the statute.

3

EA-1911: Energy Conservation Standards for Certain Reflector, Elliptical Reflector, and Bulged Reflector Incandescent Lamps  

Energy.gov (U.S. Department of Energy (DOE))

This EA will evaluate the environmental impacts of a proposal to amend energy conservation standards for Certain Reflector, Elliptical Reflector, and Bulged Reflector Incandescent Lamps.

4

Convection venting lensed reflector-type compact fluorescent lamp system  

DOE Patents (OSTI)

Disclosed herein is a fluorescent lamp housing assembly capable of providing convection cooling to the lamp and the ballast. The lens of the present invention includes two distinct portions, a central portion and an apertured portion. The housing assembly further includes apertures so that air mass is able to freely move up through the assembly and out ventilation apertures. 12 figs.

Pelton, B.A.; Siminovitch, M.

1997-07-29T23:59:59.000Z

5

Convection venting lensed reflector-type compact fluorescent lamp system  

SciTech Connect

Disclosed herein is a fluorescent lamp housing assembly capable of providing convection cooling to the lamp and the ballast. The lens of the present invention includes two distinct portions, a central portion and an apertured portion. The housing assembly further includes apertures so that air mass is able to freely move up through the assembly and out ventilation apertures.

Pelton, Bruce A. (825 Manor Rd., El Sobrante, CA 94803); Siminovitch, Michael (829 Manor Rd., El Sobrante, CA 94803)

1997-01-01T23:59:59.000Z

6

A light diet for a giant appetite: An assessment of China's proposed fluorescent lamp standard  

SciTech Connect

Lighting has been one of the fastest growing electric end-uses in China over the last twenty years, with an average annual growth rate of 14%. Fluorescent lighting provides a significant portion of China's lighting need. In 1998, China produced 680 million fluorescent lamps, of which 420 million were linear fluorescent lamps of various diameters (T8 to T12). There are substantial variations both in energy efficiency and lighting performance among locally produced fluorescent lamps. Such variations present a perfect opportunity for policy intervention through efficiency standards to promote the adoption of more efficient fluorescent lamps in China. This paper analyzes China's proposed minimum efficiency standard for fluorescent lamps and presents an assessment of its likely impacts on China's lighting energy consumption and GHG emissions.

Lin, Jiang

2002-04-11T23:59:59.000Z

7

Studies on Temperature Dependence of Rubidium Lamp for Atomic Frequency Standard  

Science Conference Proceedings (OSTI)

Rb lamp is a very critical component of the Rb atomic clock's Physics Package. The Rb lamp's performance is very sensitive to temperature and its stability. In this paper we discuss the behaviors of Rb Lamp with temperature. The Rb lamp exciter power and temperature of Rb bulb are very important parameters in controlling the performance of the Rb Lamp. It is observed that at temperatures beyond 110 deg. C, the lamp mode changes from the ring to red mode resulting in abnormal broadening of emission lines and self reversal. The results of our studies on spectral analysis of Rb lamp under various operating conditions are reported in the paper.

Ghosal, Bikash; Banik, Alak; Vats, Vaibhav; Pal, Sukamal; Bahl, R. K [Space Applications Centre, ISRO, Ahmedabad-380015 (India)

2011-10-20T23:59:59.000Z

8

DOE/EA-1664: Environmental Assessment for 10 CFR 430 Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent Lamps (June 2009)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4 4 Environmental Assessment for 10 CFR Part 430 Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent Lamps June 2009 16-i CHAPTER 16. ENVIRONMENTAL ASSESSMENT TABLE OF CONTENTS 16.1 INTRODUCTION ......................................................................................................... 16-1 16.2 AIR EMISSIONS ANALYSIS...................................................................................... 16-1 16.2.1 Air Emissions Descriptions............................................................................................ 16-1 16.2.2 Air Quality Regulation................................................................................................... 16-3 16.2.3 Global Climate Change..................................................................................................

9

Lighting Group: Sources and Ballasts: LED Reflector Lamp  

NLE Websites -- All DOE Office Websites (Extended Search)

LED Reflector Lamp LED Reflector Lamp LED Reflector Lamp Objective LED reflector lamp The goal of this project is to develop a revolutionary new reflector lamp which offers many advantages over current incandescent reflector lamps, including: three times greater efficiency ten times the rated life greater optical and performance properties use of light emitting diodes (LEDs) to generate the light. Although LEDs have been commercially available since the late 1960’s, recent dramatic improvements in LED technology have led to white light devices with efficiencies that meet or exceed those of a standard incandescent lamp. This project will build upon these improvements to develop a new type of source for focusing light. Contact Information For more information on this project, please contact:

10

The Energy Efficiency of the U.S Fluorescent Lamp Ballast Industry  

NLE Websites -- All DOE Office Websites (Extended Search)

The Energy Efficiency of the U.S Fluorescent Lamp Ballast Industry The Energy Efficiency of the U.S Fluorescent Lamp Ballast Industry Speaker(s): Francis Rubinstein Date: February 14, 2008 - 12:00pm Location: 90-3122 Fluorescent lamp ballasts are subject to DOE appliance standards and rulemaking. But currently, only ballasts for older fluorescent lamp types, such as T-12 lamps are subject to minimum efficacy limits. The majority of fluorescent lamps now being shipped (T-8 and T-5 types) type are operated by ballasts that will not be subject to DOE rule until 2011. The metric used by DOE for characterizing the electrical efficiency of the fluorescent lamp-ballast system is called Ballast Efficacy Factor (BEF). Because BEF is not normalized, it is of limited utility for rulemaking and is useless for procurement. But by normalizing BEF to the total lamp power, I have

11

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Certain Lamps Exempted from General Service Incandescent Lamp Standards Certain Lamps Exempted from General Service Incandescent Lamp Standards Sign up for e-mail updates on regulations for this and other products The information on this page pertains to the Department of Energy's (DOE) analysis of and unit sales forecast for five lamp types, which was mandated by the Energy Independence and Security Act of 2007 (EISA 2007). Among the requirements of subtitle B of title III of EISA 2007 were provisions directing DOE to evaluate and publish within 1 year a benchmark unit sales estimate for five types of incandescent lamps (rough service lamps, vibration service lamps, 3-way incandescent lamps, 2,601-3,300 lumen general service incandescent lamps, and shatter-resistant lamps). These lamp types were not made subject to the regulatory standards for general service incandescent lamps established by EISA 2007. Among the requirements of subtitle B of title III of EISA 2007 were provisions directing DOE to collect, analyze, and monitor unit sales of these five lamp types.

12

Jacketed lamp bulb envelope  

DOE Patents (OSTI)

A jacketed lamp bulb envelope includes a ceramic cup having an open end and a partially closed end, the partially closed end defining an aperture, a lamp bulb positioned inside the ceramic cup abutting the aperture, and a reflective ceramic material at least partially covering a portion of the bulb not abutting the aperture. The reflective ceramic material may substantially fill an interior volume of the ceramic cup not occupied by the bulb. The ceramic cup may include a structural feature for aiding in alignment of the jacketed lamp bulb envelope in a lamp. The ceramic cup may include an external flange about a periphery thereof. One example of a jacketed lamp bulb envelope includes a ceramic cup having an open end and a closed end, a ceramic washer covering the open end of the ceramic cup, the washer defining an aperture therethrough, a lamp bulb positioned inside the ceramic cup abutting the aperture, and a reflective ceramic material filling an interior volume of the ceramic cup not occupied by the bulb. A method of packing a jacketed lamp bulb envelope of the type comprising a ceramic cup with a lamp bulb disposed therein includes the steps of filling the ceramic cup with a flowable slurry of reflective material, and applying centrifugal force to the cup to pack the reflective material therein.

MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD); Gitsevich, Aleksandr (Gaithersburg, MD); Bass, Gary K. (Mt. Airy, MD); Dolan, James T. (Frederick, MD); Kipling, Kent (Gaithersburg, MD); Kirkpatrick, Douglas A. (Great Falls, VA); Leng, Yongzhang (Damascus, MD); Levin, Izrail (Silver Spring, MD); Roy, Robert J. (Frederick, MD); Shanks, Bruce (Gaithersburg, MD); Smith, Malcolm (Alexandria, VA); Trimble, William C. (Columbia, MD); Tsai, Peter (Olney, MD)

2001-01-01T23:59:59.000Z

13

Compatibility testing of fluorescent lamp and ballast systems  

SciTech Connect

The rapid growth in the use of electronic ballasts for fluorescent lighting systems, and the corresponding increase in the number of new products and new manufacturers in the market, has raised a number of questions regarding the compatibility of the lamps and ballasts used in fluorescent systems. Because many of the new products start and operate lamps differently than previous products, the relevant American National Standards Institute requirements may no longer be adequate for addressing compatibility concerns. The impacts on system performance of the newer products of a parametric study designed to test key hypotheses regarding the impact of ballast parameters on fluorescent lamp life. In this study, samples of 4-ft T8 fluorescent lamps were operated on duty cycles of 5 min on and 5 min off, using seven different ballast types. The results of the study indicate which parameters seem to have the biggest effect on lamp life, and can be used in establishing new performance standards for fluorescent systems.

Ji, Y.; Davis, R.; O' Rourke, C.; Chui, E.W.M.

1999-12-01T23:59:59.000Z

14

DuraLamp USA: Order (2010-CE-0912)  

Energy.gov (U.S. Department of Energy (DOE))

DOE ordered DuraLamp USA, Inc. to pay a $2,500 civil penalty after finding DuraLamp USA had failed to certify that model PAR 30, an incandescent reflector lamp, complies with the applicable energy conservation standards.

15

Fixture conditions affect lamp performance  

SciTech Connect

This article discusses the major parameters that affect fluorescent lamp performance under fixture conditions. These parameters include fixture type, and HVAC integration, which directly determine the minimum lamp wall temperature (MLWT), and therefore, the resulting light output of the lamp/ballast system. Experimental data is presented showing that the lumen output of the lamp/ballast system can vary by as much as 20% and that the system efficacy can vary by 10% depending upon the type of fixture and HVAC system employed. 4 refs., 5 figs., 1 tab.

Siminovitch, M.J.; Rubinstein, F.M.; Verderber, R.R.

1986-11-01T23:59:59.000Z

16

Aperture lamp  

DOE Patents (OSTI)

A discharge lamp includes means for containing a light emitting fill, the fill being capable of absorbing light at one wavelength and re-emitting the light at a different wavelength, the light emitted from the fill having a first spectral power distribution in the absence of reflection of light back into the fill; means for exciting the fill to cause the fill to emit light; and means for reflecting some of the light emitted by the fill back into the fill while allowing some light to exit, the exiting light having a second spectral power distribution with proportionately more light in the visible region as compared to the first spectral power distribution, wherein the light re-emitted by the fill is shifted in wavelength with respect to the absorbed light and the magnitude of the shift is in relation to an effective optical path length. Another discharge lamp includes an envelope; a fill which emits light when excited disposed in the envelope; a source of excitation power coupled to the fill to excite the fill and cause the fill to emit light; and a reflective ceramic structure disposed around the envelope and defining an light emitting opening, wherein the structure comprises a sintered body built up directly on the envelope and made from a combination of alumina and silica.

MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD)

2003-01-01T23:59:59.000Z

17

Lamp Divisions  

Office of Legacy Management (LM)

--- --- /A;; i :' r%i;in~house ilEc;' i:Z3:~cra:ion Lamp Divisions , _.. (I +i. 0 :,,,rg. . I . . -= i?e p/q! qe)-' &se pw E.rcale?l iev, Je!sey 07m March 20, 1 gs? ::r . J. A. Jones I ti. 5. Muclear Regulatory Commission .> = ..- haterials Licensing Branch -s - ,.I, - - Division of Fuel Cycle and hateri al Safety LY. , $2 - _ . ' -' . 3 _- - Yeshington, C. C. 2@555 - :_ :--, =-- -- .-?J -.: y...., : :- 7 Dear Mr. Jones : y-- --, ? . *I 2=15 2 r; X -P The following is our final report of the decontamination efZor?s takz in our Bui Iding 7 basement and wi 11 also serve to update our report i& November 12, 1980. As stated in NRC' s report of December 22, 1983, two closeout inspect ions were conducted by your King of Prussia off i ce on November 21 and December 2,

18

LED lamp  

SciTech Connect

There is herein described a lamp for providing white light comprising a plurality of light sources positioned on a substrate. Each of said light sources comprises a blue light emitting diode (LED) and a dome that substantially covers said LED. A first portion of said blue light from said LEDs is transmitted through said domes and a second portion of said blue light is converted into a red light by a first phosphor contained in said domes. A cover is disposed over all of said light sources that transmits at least a portion of said red and blue light emitted by said light sources. The cover contains a second phosphor that emits a yellow light in response to said blue light. The red, blue and yellow light combining to form the white light and the white light having a color rendering index (CRI) of at least about 80.

Galvez, Miguel; Grossman, Kenneth; Betts, David

2013-11-12T23:59:59.000Z

19

Building Technologies Office: Fluorescent and Incandescent Lamps Public  

NLE Websites -- All DOE Office Websites (Extended Search)

Fluorescent and Fluorescent and Incandescent Lamps Public Meeting to someone by E-mail Share Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Facebook Tweet about Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Twitter Bookmark Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Google Bookmark Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Delicious Rank Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Digg Find More places to share Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on AddThis.com... About Standards & Test Procedures Implementation, Certification & Enforcement

20

Spectral irradiance model for tungsten halogen lamps in 340-850 nm wavelength range  

Science Conference Proceedings (OSTI)

We have developed a physical model for the spectral irradiance of 1 kW tungsten halogen incandescent lamps for the wavelength range 340-850 nm. The model consists of the Planck's radiation law, published values for the emissivity of tungsten, and a residual spectral correction function taking into account unknown factors of the lamp. The correction function was determined by measuring the spectra of a 1000 W, quartz-halogen, tungsten coiled filament (FEL) lamp at different temperatures. The new model was tested with lamps of types FEL and 1000 W, 120 V quartz halogen (DXW). Comparisons with measurements of two national standards laboratories indicate that the model can account for the spectral irradiance values of lamps with an agreement better than 1% throughout the spectral region studied. We further demonstrate that the spectral irradiance of a lamp can be predicted with an expanded uncertainty of 2.6% if the color temperature and illuminance values for the lamp are known with expanded uncertainties of 20 K and 2%, respectively. In addition, it is suggested that the spectral irradiance may be derived from resistance measurements of the filament with lamp on and off.

Ojanen, Maija; Kaerhae, Petri; Ikonen, Erkki

2010-02-10T23:59:59.000Z

Note: This page contains sample records for the topic "lamp type standard" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

ENVIRONMENTAL ASSESSMENT FOR PROPOSED ENERGY CONSERVATION STANDARDS FOR EIGHT TYPES OF CONSUMER  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

ENVIRONMENTAL ASSESSMENT FOR PROPOSED ENERGY ENVIRONMENTAL ASSESSMENT FOR PROPOSED ENERGY CONSERVATION STANDARDS FOR EIGHT TYPES OF CONSUMER PRODUCTS: ROOM AIR CONDITIONERS, WATER HEATERS, DIRECT HEATING EQUI?MENT, MOBILE HOME FURNACES, RANGES AND OVENS, POOL HEATERS, FLUORESCENT BALLASTS, AND TELEVISIONS INTRODUCTION AND NEED FOR PROPOSEI) ACTION This Environmental Assessment (EA) on the candidate energy conservation standards for eight appliances (room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts, and television sets) was prepared pursuant to the National Environmental Policy Act of 1969 (NEPA), regulations of the Council on Environmental Quality, Title 40, Code of Federal Regulations, Parts 1500 through 1508. The candidate conservation standards are being

22

Energy Cost Calculator for Compact Fluorescent Lamps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Compact Fluorescent Lamps Compact Fluorescent Lamps Energy Cost Calculator for Compact Fluorescent Lamps October 8, 2013 - 2:18pm Addthis This tool calculates the payback period for your calc retrofit project. Modify the default values to suit your project requirements. Existing incandescent lamp wattage Watts Incandescent lamp cost dollars Incandescent lamp life 1000 hours calc wattage Watts calc cost dollars calc life (6000 hours for moderate use, 10000 hours for high use) 8000 hours Number of lamps in retrofit project Hours operating per week hours Average cost of electricity 0.06 $/kWh Relamper labor costs $/hr Time taken to retrofit all lamps in this project min Time taken to relamp one lamp min Type of Relamping Practiced: Group Relamping: Calculate Simple Payback Period months

23

Compact Fluorescent Lamps  

Science Conference Proceedings (OSTI)

Electric lighting constitutes approximately 21-23 % of the electric grid load in the United States. The higher energy and maintenance costs of incandescent lamps, combined with the favorable economics of high-efficiency compact fluorescent lamps (CFLs), are making CFLs the increasingly popular choice for both residential and commercial lighting. Utility incentive and rebate programs to stimulate CFL use and the beginnings of a ban on incandescent lamps are enhancing CFL penetration levels in these enviro...

2009-12-17T23:59:59.000Z

24

Stadiums and arenas use efficient, high wattage lamps - Today ...  

U.S. Energy Information Administration (EIA)

Other lighting types, such as light-emitting diode (LED), incandescent, and halogen lamps, are used in applications like signals, signage, ...

25

Fluorescent lamp ballast  

SciTech Connect

An electronic ballast is described having at least a first and second terminal for engaging the filaments of at least one fluorescent lamp which requires a breakdown voltage to ignite the lamp and a maintaining voltage for maintaining ionization therewithin, the electronic ballast comprising: a direct current voltage source; a transistor; a transformer having a primary winding separated into a first winding, a second winding, a third winding, and a fourth winding; the first winding connected between the voltage source and the first terminal; the second winding connected between the two terminals; the third winding connected between the second terminal and to both the transistor and to ground; the fourth winding connected between ground and the transistor; the lamp being parallel to the second winding when the lamp filaments engages the ballast terminals.

Ureche, A.

1987-08-25T23:59:59.000Z

26

Magnetic fluorescent lamp  

DOE Patents (OSTI)

The radiant emission of a mercury-argon discharge in a fluorescent lamp assembly is enhanced by providing means for establishing a magnetic field with lines of force along the path of electron flow through the bulb of the lamp assembly, to provide Zeeman splitting of the ultraviolet spectral line. Optimum results are obtained when the magnetic field strength causes a Zeeman splitting of approximately 1.7 times the thermal line width.

Berman, S.M.; Richardson R.W.

1983-12-29T23:59:59.000Z

27

Electronic Compact Fluorescent Lamps  

Science Conference Proceedings (OSTI)

This EPRI Technical Update addresses the fastest growing energy efficient light source the electronic compact fluorescent lamp (CFL). Business and technical market factors (Chapter 2) explain the past and future growth of the CFL market while emphasizing future technical improvements along with discussion of the importance of utility involvement in helping their customers make the switch from incandescent lamps to CFLs. The basic CFL technology is covered in Chapter 3 including test results for selected ...

2007-12-18T23:59:59.000Z

28

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

have been required to comply with the Department of Energy (DOE) energy conservation standards for fluorescent lamp ballasts since 1990. Fluorescent lamp ballasts control electric...

29

Fluorescent lamp ballast  

SciTech Connect

This patent describes an electronic ballast unit for a fluorescent lamp comprising: a circuit assembly having a pair of voltage input terminal and a first inductor and a capacitor in series relationship with each other to form a series resonant circuit. The circuit is adapted to be coupled to a fluorescent lamp to provide a starting voltage for the lamp; and a second inductor connected in shunt relationship to the first inductor and connected to the other input terminal. There is a core on which the first inductor and the second inductor are mounted. The core inductively couples the inductors with each other and are shaped to reduce core losses to minimize the increase of temperature of the core; the core is of a generally H-shaped configuration, and means of opposite ends of the H-shaped core to complete the magnetic flux path for each inductor, respectively.

Boyd, G.D.

1987-03-31T23:59:59.000Z

30

2X Incandescent Lamp Technology  

Science Conference Proceedings (OSTI)

The incandescent lamp was developed during the 1800s, largely reaching the design of the traditional incandescent lamp as we know it by the late 1800s.This lamp remained largely unchanged for years, providing most commercial and residential lighting demands into the 1950s and residential lighting into the 2000s. Asnew lighting technologies became available, the low efficacy, measured in lumens per watt, of the traditional incandescent lamp became an issue which many wanted to ...

2012-11-01T23:59:59.000Z

31

Survivability of Electronic Compact Fluorescent Lamps  

Science Conference Proceedings (OSTI)

This EPRI Technical Report addresses the fastest growing energy efficient light source8212the electronic compact fluorescent lamp (CFL). Because some of the failure modes for screw-in CFLs are different than those for plug-in CFLs, a cursory review of the difference between the two types of CFLs is provided in the first part of Chapter 2. A broad definition of shortened-life CFLs is also provided in Chapter 2 with an emphasis on revisiting mortality curves, the 10-minute lamp start, other relevant defini...

2008-03-31T23:59:59.000Z

32

Fluorescent lamp dimming adaptor kit  

SciTech Connect

An add-on fluorescent lamp dimming adaptor is described for connecting to a conventional nondimming ballast in a fluorescent lighting system, the system including a source of ac voltage. The ballast has terminals for connecting to a fluorescent lamp, the adaptor comprising: a switching module adapted to be coupled to the terminals for switching current from the lamp, the switching module being connected in parallel with the lamp to divert current from the lamp when the switching module conducts; and a level control coupled to the switching module, the level control controlling the conductive state of the switching module to vary the current in the lamp according to a dimming control signal supplied to the level control, the level control causing the switching module to switch at a frequency in the range of 300 hertz and higher during times that the lamp current is being varied.

Alley, R.P.

1987-07-21T23:59:59.000Z

33

EA-1881: Energy Conservation Program: Energy Conservation Standards...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1: Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts EA-1881: Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp...

34

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

High-Intensity Discharge Lamps High-Intensity Discharge Lamps Sign up for e-mail updates on regulations for this and other products There are currently no energy conservation standards for high-intensity discharge (HID) lamps. HID lamps are electric discharge lamps and include high-pressure sodium, mercury vapor, and metal halide lamps. HID lamps require an HID ballast to start and regulate electric current flow through the lamp. HID lamps are used in street and roadway lighting, area lighting such as for parking lots and plazas, industrial and commercial building interior lighting, security lighting for commercial, industrial, and residential spaces, and landscape lighting. The Standards and Test Procedures for this product are related to Rulemaking for High Intensity Discharge Lamps Energy Conservation Standard and Rulemaking for High Intensity Discharge Lamps Test Procedures.

35

Effect of filament power removal on a fluorescent lamp system  

SciTech Connect

Two techniques are used to measure the effects of removing the filament power from a two-lamp, F-40, rapid-start fluorescent lamp system. The changes are measured for a standard CBM core-coil ballast and for a solid-state ballast operating the lamp at high frequency. There is a 4 tp 6% increase in system efficacy when the filament power is removed. Removal of filament power also decreases filament temperature from 1000/sup 0/C to below 700/sup 0/C in lamps operated at 60 Hz, and from above 600/sup 0/C to 300/sup 0/C in lamps operated at high frequency. The study shows that the arc current and anode fall also determine filament temperature.

Verderber, R.R.; Morse, O.; Rubinstein, F.M.

1985-07-01T23:59:59.000Z

36

Inrush related problems caused by lamps with electronic drivers and their mitigation  

Science Conference Proceedings (OSTI)

New types of appliances sometimes bring unexpected power quality problems. On several locations it was reported that energy-saving lamps cause random false tripping of circuit breakers. In all of these cases these lamps had electronic drivers. An investigation ... Keywords: energy-saving lamp, false tripping, inrush, mitigation, power quality

Vladimir ?uk; Joseph F. G. Cobben; Wil L. Kling

2011-07-01T23:59:59.000Z

37

Flash Lighting with Fluorescent Lamp.  

E-Print Network (OSTI)

??A flash lighting circuit with the fluorescent lamp is designed to produce lighting flicker by means of controlling the operating frequency and the duty-ratio of (more)

Hsieh, Horng

2005-01-01T23:59:59.000Z

38

DuraLamp USA: Proposed Penalty (2010-CE-0912) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DuraLamp USA: Proposed Penalty (2010-CE-0912) DuraLamp USA: Proposed Penalty (2010-CE-0912) DuraLamp USA: Proposed Penalty (2010-CE-0912) September 9, 2010 DOE alleged in a Notice of Proposed Civil Penalty that DuraLamp USA, Inc. failed to certify a variety of general service fluorescent lamps as compliant with the applicable energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. DuraLamp USA: Proposed Penalty (2010-CE-0912) More Documents & Publications DuraLamp USA: Order (2010-CE-0912)

39

Energy and Economic Impacts of U.S. Federal Energy and Water Conservation Standards Adopted From 1987 Through 2011  

E-Print Network (OSTI)

The Effect of Efficiency Standards on Water Use and Water1989. Lamp Efficiency Standards for Massachusetts: AnalysisNational Efficiency Standards for Lamps, Motors, Showerheads

Meyers, Stephen

2013-01-01T23:59:59.000Z

40

Inductive tuners for microwave driven discharge lamps  

DOE Patents (OSTI)

An RF powered electrodeless lamp utilizing an inductive tuner in the waveguide which couples the RF power to the lamp cavity, for reducing reflected RF power and causing the lamp to operate efficiently.

Simpson, James E. (Gaithersburg, MD)

1999-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "lamp type standard" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Information Resources: LED Replacement Lamps: Current Performance...  

NLE Websites -- All DOE Office Websites (Extended Search)

incandescent lamps (e.g., A-lamps), and provided an update on ENERGY STAR criteria for LED integral replacement lamps - currently in its second draft. Robert Lingard of Pacific...

42

A projective LED dental lamp design.  

E-Print Network (OSTI)

??Halogen lamps are mostly applied as a light source to the traditional lamp for medical treatment due to its proper color temperature, but it has (more)

Chung, Yu-Lin

2011-01-01T23:59:59.000Z

43

Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 1, Methodology  

SciTech Connect

The Energy Policy and Conservation Act (P.L. 94-163), as amended, establishes energy conservation standards for 12 of the 13 types of consumer products specifically covered by the Act. The legislation requires the Department of Energy (DOE) to consider new or amended standards for these and other types of products at specified times. DOE is currently considering amending standards for seven types of products: water heaters, direct heating equipment, mobile home furnaces, pool heaters, room air conditioners, kitchen ranges and ovens (including microwave ovens), and fluorescent light ballasts and is considering establishing standards for television sets. This Technical Support Document presents the methodology, data, and results from the analysis of the energy and economic impacts of the proposed standards. This volume presents a general description of the analytic approach, including the structure of the major models.

Not Available

1993-11-01T23:59:59.000Z

44

Energy-efficient compact screw-in fluorescent lamp. Final report  

SciTech Connect

A compact fluorescent lamp has been designed and constructed which can replace an incandescent lamp. The lamp is slightly larger than a standard lamp (8 3/4 in. x 3 1/4 in.), but is designed to fit a majority of portable lamp applications. This version, with a core-coil ballast, results in a system efficacy of 54 lumens per watt, with a light output of more than 1800 lumens. This compares favorably with a 100-watt incandescent (17.5 lumens per watt and 1750 lumens light output). The color temperature of 3000/sup 0/K is compatible with an incandescent lamp (2800/sup 0/K). The color rendition index (CRI) is 84. With a solid-state ballast, the efficacy and light output could be increased by 20% (65 l/w, 2200 lumens) and could provide a direct replacement for a three-way, 150-watt incandescent lamp (15 l/w, 2200 lumens).

Morton, E.W.

1982-11-01T23:59:59.000Z

45

Max Tech and Beyond: High-Intensity Discharge Lamps  

Science Conference Proceedings (OSTI)

High-intensity discharge (HID) lamps are most often found in industrial and commercial applications, and are the light source of choice in street and area lighting, and sports stadium illumination. HID lamps are produced in three types - mercury vapor (MV), high pressure sodium (HPS) and metal halide (MH). Of these, MV and MH are considered white-light sources (although the MV exhibits poor color rendering) and HPS produces a yellow-orange color light. A fourth lamp, low-pressure sodium (LPS), is not a HID lamp by definition, but it is used in similar applications and thus is often grouped with HID lamps. With the notable exception of MV which is comparatively inefficient and in decline in the US from both a sales and installed stock point of view; HPS, LPS and MH all have efficacies over 100 lumens per watt. The figure below presents the efficacy trends over time for commercially available HID lamps and LPS, starting with MV and LPS in 1930's followed by the development of HPS and MH in the 1960's. In HID lamps, light is generated by creating an electric arc between two electrodes in an arc tube. The particles in the arc are partially ionized, making them electrically conductive, and a light-emitting 'plasma' is created. This arc occurs within the arc tube, which for most HID lamps is enclosed within an evacuated outer bulb that thermally isolates and protects the hot arc tube from the surroundings. Unlike a fluorescent lamp that produces visible light through down-converting UV light with phosphors, the arc itself is the light source in an HID lamp, emitting visible radiation that is characteristic of the elements present in the plasma. Thus, the mixture of elements included in the arc tube is one critical factor determining the quality of the light emitted from the lamp, including its correlated color temperature (CCT) and color rendering index (CRI). Similar to fluorescent lamps, HID lamps require a ballast to start and maintain stable operating conditions, and this necessitates additional power beyond that used by the lamp itself. HID lamps offer important advantages compared to other lighting technologies, making them well suited for certain applications. HID lamps can be very efficient, have long operating lives, are relatively temperature-insensitive and produce a large quantity of light from a small package. For these reasons, HID lamps are often used when high levels of illumination are required over large areas and where operating and maintenance costs must be kept to a minimum. Furthermore, if the installation has a significant mounting height, high-power HID lamps can offer superior optical performance luminaires, reducing the number of lamps required to illuminate a given area. The indoor environments best suited to HID lamps are those with high ceilings, such as those commonly found in industrial spaces, warehouses, large retail spaces, sports halls and large public areas. Research into efficacy improvements for HID lighting technologies has generally followed market demand for these lamps, which is in decline for MV and LPS, has reached a plateau for HPS and is growing for MH. Several manufacturers interviewed for this study indicated that although solid-state lighting was now receiving the bulk of their company's R&D investment, there are still strong HID lamp research programs, which concentrate on MH technologies, with some limited amount of investment in HPS for specific niche applications (e.g., agricultural greenhouses). LPS and MV lamps are no longer being researched or improved in terms of efficacy or other performance attributes, although some consider MH HID lamps to be the next-generation MV lamp. Thus, the efficacy values of commercially available MV, LPS and HPS lamps are not expected to increase in the next 5 to 10 years. MH lamps, and more specifically, ceramic MH lamps are continuing to improve in efficacy as well as light quality, manufacturability and lamp life. Within an HID lamp, the light-producing plasma must be heated to sufficiently high temperatures to achieve high efficiencie

Scholand, Michael

2012-04-01T23:59:59.000Z

46

Performance of electronic ballasts and lighting controllers with 34-W fluorescent lamps: Final report  

SciTech Connect

This study has measured the performance of energy-saving 34-watt F40, T-12, rapid-start, lite white fluorescent lamps being operated by solid-state ballasts and lighting control equipment. The performances of these lamps are compared with those of 40-watt F40, T-12 rapid-start cool white fluorescent lamp systems studied in the prior phase of this project. With the 34-watt F40 lamps and various solid-state ballasts, system efficacy ranged from 67 to 84 lumens per watt and ballast factor from 0.756 to 0.908. Average system efficacy using the 34-watt lamps exceeded that of systems using 40-watt lamps and the same solid-state ballasts by only 1 percent even though the 34-watt lamps is about 6 percent more efficacious than the 40-watt lamp. This apparent discrepancy is due to increased ballast losses when operating the 34-watt lamps. However, the system efficacy of the 34-watt lamps used with a solid-state ballast exceeded that of a 34-watt, two-lamp system using the standard core-coil ballast by as much as 29 percent. A T-8 fluorescent lamp system with a smaller lamp diameter was also included in the study. Operating this lamp with a solid-state ballast produced a high system efficacy of 90 lumens per watt, a 39 percent improvement over the efficacy of a 40-watt F40 system using the standard core-coil ballast. The use of static controllers with 34-watt F40 lamps can result in excessive flickering (46 percent) and the generation of a second harmonic as high as 96 percent of the fundamental frequency. The dynamic controllers, when used to dim the 34-watt lamps generally cannot be dimmed as low as the 40-watt lamp system without flickering. In general, the 34-watt energy-saving lamps are appropriate as a retrofit to reduce illumination levels. However, for new construction, the 40-watt F40 argon filled lamps cost less, perform better, and provide a more reliable system. 5 refs., 27 figs., 9 tabs.

Verderber, R.R.

1988-06-01T23:59:59.000Z

47

One piece microwave container screens for electrodeless lamps  

DOE Patents (OSTI)

A microwave powered electrodeless lamp includes an improved screen unit having mesh and solid sections with an internal reflector to reflect light into a light-transmitting chamber defined in the lamp microwave cavity by the reflector and the mesh section. A discharge envelope of a bulb is disposed in the light-transmitting chamber. Light emitted from the envelope is prevented by the reflector from entering the cavity portion bounded by the solid section of the screen. Replacing mesh material by solid metal material as part of the screen unit significantly reduces leakage of microwave energy from the lamp. The solid section has multiple compliant fingers defined therein for engaging the periphery of a flange on the waveguide unit so that a hose clamp can easily secure the screen to the assembly. Screen units of this type having different mesh section configurations can be interchanged in the lamp assembly to produce different respective illumination patterns.

Turner, Brian (Myersville, MD); Ury, Michael (Bethesda, MD)

1998-01-01T23:59:59.000Z

48

Performance of T12 and T8 Fluorescent Lamps and Troffers and LED Linear Replacement Lamps CALiPER Benchmark Report  

Science Conference Proceedings (OSTI)

The Department of Energy (DOE) Commercially Available LED Product Evaluation and Reporting (CALiPER) Program was established in 2006 to investigate the performance of light-emitting diode (LED) based luminaires and replacement lamps. To help users better compare LED products with conventional lighting technologies, CALiPER has also performed benchmark research and testing of traditional (i.e., non-LED) lamps and fixtures. This benchmark report addresses standard 4-foot fluorescent lamps (i.e., T12 and T8) and the 2-foot by 4-foot recessed troffers in which they are commonly used. This report also examines available LED replacements for T12 and T8 fluorescent lamps, and their application in fluorescent troffers. The construction and operation of linear fluorescent lamps and troffers are discussed, as well as fluorescent lamp and fixture performance, based on manufacturer data and CALiPER benchmark testing. In addition, the report describes LED replacements for linear fluorescent lamps, and compares their bare lamp and in situ performance with fluorescent benchmarks on a range of standard lighting measures, including power usage, light output and distribution, efficacy, correlated color temperature, and the color rendering index. Potential performance and application issues indicated by CALiPER testing results are also examined.

Myer, Michael; Paget, Maria L.; Lingard, Robert D.

2009-01-16T23:59:59.000Z

49

The effects of supply harmonics on the performance of compact fluorescent lamps  

SciTech Connect

This paper describes a performance evaluation of ten compact fluorescent lighting systems operated with sinusoidal and distorted voltage waveform conditions. The lamps were either provided with an electronic ballast, a magnetic core ballast or a magnetic core ballast with a power factor correction circuit. The test results show that the electrical performance of the compact fluorescent lamps for both sinusoidal and distorted voltage waveform operation is related to the different types of ballast used. The cost of operation of these compact fluorescent lamps was calculated and compared to the cost of a conventional 60 W incandescent lamp.

Arseneau, R.; Ouellette, M.

1993-04-01T23:59:59.000Z

50

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Light Emitting Diode Lamps Light Emitting Diode Lamps Sign up for e-mail updates on regulations for this and other products There are currently no energy conservation standards for light emitting diode (LED) lamps.LED lamps are comprised of an LED source, such as LED packages or LED arrays; an LED driver; an American National Standards Institute (ANSI) standard base, and other optical, thermal, mechanical, and electrical components. These LED lamps are primarily used in residential applications as replacement lamps. The Department of Energy (DOE) will conduct an analysis of the energy, emissions, and costs associated with LEDs during any future energy conservation standard rulemakings. The Standards and Test Procedures for this product are related to Rulemaking for Light-Emitting Diode Lamps Test Procedure.

51

standards  

Science Conference Proceedings (OSTI)

... About Circular A-119About Us. Standards. Definition of Standards. Finding Standards. Information on Biometrics Standards.

2012-12-13T23:59:59.000Z

52

Lamp bulb with integral reflector  

SciTech Connect

An improved electrodeless discharge lamp bulb includes an integral ceramic reflector as a portion of the bulb envelope. The bulb envelope further includes two pieces, a reflector portion or segment is cast quartz ceramic and a light transmissive portion is a clear fused silica. In one embodiment, the cast quartz ceramic segment includes heat sink fins or stubs providing an increased outside surface area to dissipate internal heat. In another embodiment, the quartz ceramic segment includes an outside surface fused to eliminate gas permeation by polishing.

Levin, Izrail (Silver Spring, MD); Shanks, Bruce (Gaithersburg, MD); Sumner, Thomas L. (Wheaton, MD)

2001-01-01T23:59:59.000Z

53

Energy saving controller for fluorescent lamps.  

E-Print Network (OSTI)

??Although fluorescent lamp is a very efficient lighting device in daily life, still the high harmonic distortion and low power factor cause unnecessary energy consumption. (more)

Cheong, Zhi Xiong

2010-01-01T23:59:59.000Z

54

Buildings Energy Data Book: 7.7 Efficiency Standards for Lighting  

Buildings Energy Data Book (EERE)

Efficiency Standards for Lighting Efficiency Standards for Lighting March 2011 7.7.2 Efficiency Standards for General Service Fluorescent Lamps Effective for products manufactured before July 14, 2012 Minimum Nominal Lamp Average Lamp Lamp Type (1) Wattage (W) Minimum CRI Efficacy (lm/W) Effective Date 4-Foot Medium Bipin >35 69 75.0 November 1, 1995 4-Foot Medium Bipin 45 75.0 November 1, 1995 2-Foot U-Shaped >35 69 68.0 November 1, 1995 2-Foot U-Shaped 45 64.0 November 1, 1995 8-Foot Slimline >65 69 80.0 May 1, 1994 8-Foot Slimline 45 80.0 May 1, 1994 8-Foot High Output >100 69 80.0 May 1, 1994 8-Foot High Output 45 80.0 May 1, 1994 Effective for products manufactured on or after July 14, 2012 Minimum Correlated Color Average Lamp Lamp Type Temperature (K) Efficacy (lm/W) 4-Foot Medium Bipin 89 4-Foot Medium Bipin 88 2-Foot U-Shaped

55

Discharge lamp with reflective jacket  

DOE Patents (OSTI)

A discharge lamp includes an envelope, a fill which emits light when excited disposed in the envelope, a source of excitation power coupled to the fill to excite the fill and cause the fill to emit light, and a reflector disposed around the envelope and defining an opening, the reflector being configured to reflect some of the light emitted by the fill back into the fill while allowing some light to exit through the opening. The reflector may be made from a material having a similar thermal index of expansion as compared to the envelope and which is closely spaced to the envelope. The envelope material may be quartz and the reflector material may be either silica or alumina. The reflector may be formed as a jacket having a rigid structure which does not adhere to the envelope. The lamp may further include an optical clement spaced from the envelope and configured to reflect an unwanted component of light which exited the envelope back into the envelope through the opening in the reflector. Light which can be beneficially recaptured includes selected wavelength regions, a selected polarization, and selected angular components.

MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD); Kipling, Kent (Gaithersburg, MD)

2001-01-01T23:59:59.000Z

56

Table lamp with dynamically controlled lighting distribution and uniformly illuminated luminous shade  

DOE Patents (OSTI)

A double lamp table or floor lamp lighting system has a pair of compact fluorescent lamps (CFLs) or other lamps arranged vertically, i.e. one lamp above the other, with a reflective septum in between. By selectively turning on one or both of the CFLs, down lighting, up lighting, or both up and down lighting is produced. The control system can also vary the light intensity from each CFL. The reflective septum ensures that almost all the light produced by each lamp will be directed into the desired light distribution pattern which is selected and easily changed by the user. In a particular configuration, the reflective septum is bowl shaped, with the upper CFL sitting in the bowl, and a luminous shade hanging down from the bowl. The lower CFL provides both task lighting and uniform shade luminance. Planar compact fluorescent lamps, e.g. circular CFLs, particularly oriented horizontally, are preferable. CFLs provide energy efficiency. However, other types of lamps, including incandescent, halogen, and LEDs can also be used in the fixture. The lighting system may be designed for the home, hospitality, office or other environments.

Siminovitch, Michael J. (Pinole, CA); Page, Erik R. (Berkeley, CA)

2002-01-01T23:59:59.000Z

57

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

General Service Fluorescent and Incandescent Reflector Lamps Energy Conservation Standard Sign up for e-mail updates on regulations for this and other products The Department of...

58

Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 2, Fluorescent lamp ballasts, television sets, room air conditioners, and kitchen ranges and ovens  

SciTech Connect

This document is divided into ``volumes`` B through E, dealing with individual classes of consumer products. Chapters in each present engineering analysis, base case forecasts, projected national impacts of standards, life-cycle costs and payback periods, impacts on manufacturers, impacts of standards on electric utilities, and environmental effects. Supporting appendices are included.

Not Available

1993-11-01T23:59:59.000Z

59

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Metal Halide Lamp Fixtures Metal Halide Lamp Fixtures Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of metal halide lamp fixtures since 2007. A metal halide lamp fixture uses a metal halide lamp and a metal halide lamp ballast. The lamp is the light source and the ballast starts and regulates current. Metal halide fixtures or lighting systems provide lighting for parking lots and streets, flood lighting, athletics facilities, big-box stores, and warehouses. The current standards will save approximately 6.4 quads of energy and result in approximately $9.6 billion in energy bill savings for products shipped from 2009-2038. The standard will avoid about 93.6 million metric tons of carbon dioxide emissions.

60

Portable lamp with dynamically controlled lighting distribution  

DOE Patents (OSTI)

A double lamp table or floor lamp lighting system has a pair of compact fluorescent lamps (CFLs) arranged vertically with a reflective septum in between. By selectively turning on one or both of the CFLs, down lighting, up lighting, or both up and down lighting is produced. The control system can also vary the light intensity from each CFL. The reflective septum insures that almost all the light produced by each lamp will be directed into the desired light distribution pattern which is selected and easily changed by the user. Planar compact fluorescent lamps, e.g. circular CFLs, particularly oriented horizontally, are preferable. CFLs provide energy efficiency. The lighting system may be designed for the home, hospitality, office or other environments.

Siminovitch, Michael J. (Pinole, CA); Page, Erik R. (Berkeley, CA)

2001-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "lamp type standard" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

High-Intensity Discharge Lamps Energy Conservation Standard High-Intensity Discharge Lamps Energy Conservation Standard Sign up for e-mail updates on regulations for this and other products High-intensity discharge (HID) lamps include mercury vapor (MV), metal halide (MH), and high-pressure sodium (HPS) lamps. The Department of Energy (DOE) is considering establishing energy conservation standards for certain HID lamps. This rulemaking is mandated by the Energy Policy and Conservation Act (EPCA). (42 USC 6311-6317) Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a notice of public meeting and availability of interim technical support document regarding energy conservation standards for high-intensity discharge lamps. 78 FR 13566 (February 28, 2013).

62

Solid-state lamp with integral occupancy sensor  

E-Print Network (OSTI)

Previous work demonstrated a retrofit proximity detector for fluorescent lamps using the lamp's own stray electric fields. This paper extends the retrofit sensor system to a solid-state (LED) lamp. The design and implementation ...

Cooley, John J.

63

Types of Lighting in Commercial Buildings - Lighting Types  

U.S. Energy Information Administration (EIA) Indexed Site

Lighting Types Lighting Types The following are the most widely used types of lighting equipment used in commercial buildings. Characteristics such as energy efficiency, light quality, and lifetime vary by lamp type. Standard Fluorescent A fluorescent lamp consists of a sealed gas-filled tube. The gas in the tube consists of a mixture of low pressure mercury vapor and an inert gas such as argon. The inner surface of the tube has a coating of phosphor powder. When an electrical current is applied to electrodes in the tube, the mercury vapor emits ultraviolet radiation which then causes the phosphor coating to emit visible light (the process is termed fluorescence). A ballast is required to regulate and control the current and voltage. Two types of ballasts are used, magnetic and electronic. Electronic ballasts

64

Compact Fluorescent Lamps : Technologies : From the Lab to the...  

NLE Websites -- All DOE Office Websites (Extended Search)

process. (Left) Compact Fluorescent Lamp; (Right) Cover of the 'Lighting Retrofit Workbook' (Left) Compact Fluorescent Lamp (CFL) (Right) Retrofitting national parks...

65

Driver Circuit for White LED Lamps with TRIAC Dimming Control.  

E-Print Network (OSTI)

??An efficient Light Emitting Diode (LED) lamp driver circuit is proposed for retrofitting the conventionally used incandescent lamps with existing TRIAC dimmer. The dimming feature (more)

Weng, Szu-Jung

2012-01-01T23:59:59.000Z

66

Applicability of the sludge processing technical standard to type IV waste tanks with high fluoride concentration  

SciTech Connect

Type IV waste tanks at the Savannah River Plant which contain ballast water (tanks 17, 18, 19, 20, and 24) have solution compositions that are generally within the database developed for corrosion protection of the sludge processing tanks. Therefore the technical standard covering tank chemistry limits during sludge processing is applicable to the Type TV tanks. However, Tank 20 contains levels of fluoride higher than those treated in the sludge processing database. To confirm the applicability of the sludge processing technical standard, cyclic potentiodynamic polarization scans for pitting susceptibility were run in a simulant of the Tank 20 contents. The nitrite inhibitor level specified by the standards did inhibit pitting corrosion in the simulant. Pitting was inhibited also at the same nitrite level but with 30 percent higher concentrations of chloride, fluoride, and sulfate. Thus the sludge processing technical standard has been shown to provide corrosion protection to type IV tanks containing ballast water.

Zapp, P.E.

1992-03-31T23:59:59.000Z

67

Lamp system for uniform semiconductor wafer heating  

SciTech Connect

A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.

Zapata, Luis E. (Livermore, CA); Hackel, Lloyd (Livermore, CA)

2001-01-01T23:59:59.000Z

68

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

High Intensity Discharge Lamps Test Procedures High Intensity Discharge Lamps Test Procedures Sign up for e-mail updates on regulations for this and other products High-intensity discharge (HID) lamps include mercury vapor (MV), metal halide (MH), and high-pressure sodium (HPS) lamps. The Department of Energy (DOE) is establishing test procedures for HID lamps. This rulemaking is mandated by the Energy Policy and Conservation Act (EPCA). ( 42 U.S.C. 6291-6309) This Rulemaking is related to the High-Intensity Discharge Lamps Standard and Test Procedure. Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a notice of proposed rulemaking regarding test procedures for HID lamps. 76 FR 77914 (Dec. 15, 2011).

69

Standard  

NLE Websites -- All DOE Office Websites (Extended Search)

Standard Standard rock For at least two generations, the depth of underground muon experiments has been reduced to depth in "standard rock." This is by definition the overburden of the Cayuga Rock Salt Mine near Ithaca, New York, where K. Greisen and collaborators made seminal observations of muons at substantial depths[1]. Ref. 1 says only "Most of the ground consists of shales of various types, with average density 2.65 g/cm 2 and average atomic number 11." Menon and Murthy later extended the definition: Z 2 /A = 5.5, Z/A = 0.5, and and ρ = 2.65 g/cm 2 [2]. It was thus not-quite-sodium. Lohmann[3] further assumed the mean excitation energy and density effect parameters were those of calcium carbonate, with no adjustments for the slight density difference. We use their definition for this most important material. (Extracted from D.E. Groom, N.V. Mokhov, and S.I. Striganov,

70

LED lamp power management system and method  

DOE Patents (OSTI)

An LED lamp power management system and method including an LED lamp having an LED controller 58; a plurality of LED channels 60 operably connected to the LED controller 58, each of the plurality of LED channels 60 having a channel switch 62 in series with at least one shunted LED circuit 83, the shunted LED circuit 83 having a shunt switch 68 in parallel with an LED source 80. The LED controller 58 reduces power loss in one of the channel switch 62 and the shunt switch 68 when LED lamp electronics power loss (P.sub.loss) exceeds an LED lamp electronics power loss limit (P.sub.lim); and each of the channel switches 62 receives a channel switch control signal 63 from the LED controller 58 and each of the shunt switches 68 receives a shunt switch control signal 69 from the LED controller 58.

Gaines, James; Clauberg, Bernd; Van Erp, Josephus A. M.

2013-03-19T23:59:59.000Z

71

Performance of electronic ballasts and other new lighting equipment: (Phase 2, The 34-watt F40 rapid start T-12 fluorescent lamp): Final report  

SciTech Connect

This study has measured the performance of energy-saving 34-watt F40, T-12, rapid-start, lite white fluorescent lamps being operated by solid-state ballasts and lighting control equipment. The performances of these lamp systems are compared with those of 40-watt F40, T-12 rapid-start cool white fluorescent lamp systems studied in the prior phase of this project. With the 34-watt F40 lamps and various solid-state ballasts, system efficacy ranged from 67 to 84 lumens per watt and ballast factor from 0.756 to 0.908. Average system efficacy using the 34-watt lamps exceeded that of systems using 40-watt lamps and the same solid-state ballasts by only 1 percent even though the 34-watt lamps is about 6 percent more efficacious than the 40-watt lamp. This apparent discrepancy is due to increased ballast losses when operating the 34-watt lamps. However, the systems efficacy of the 34-watt lamps used with a solid-state ballast exceeded that of a 34-watt, two-lamp system using the standard core-coil ballast by as much as 29 percent. A T-8 fluorescent lamp system with a smaller lamp diameter was also included in the study. Operating this lamp with a solid-state ballast produced a high system efficacy of 90 lumens per watt, a 39 percent improvement over the efficacy of a 40-watt F40 system using the standard core-coil ballast. The use of static controllers with 34-watt F40 lamps can result in excessive flickering (46 percent) and the generation of a second harmonic as high as 96 percent of the fundamental frequency. The dynamic controllers, when used to dim the 34-watt lamps generally cannot be dimmed as low as the 40-watt lamp system without flickering. In general, the 34-watt energy-saving lamps are appropriate as a retrofit to reduce illumination levels. However, for new construction, the 40-watt F40 argon filled lamps cost less, perform better, and provide a more reliable system. 5 refs., 27 figs., 9 tabs.

Verderber, R.R.; Morse, O.

1988-02-01T23:59:59.000Z

72

High frequency inductive lamp and power oscillator  

DOE Patents (OSTI)

A high frequency inductively coupled electrodeless lamp includes an excitation coil with an effective electrical length which is less than one half wavelength of a driving frequency applied thereto, preferably much less. The driving frequency may be greater than 100 MHz and is preferably as high as 915 MHz. Preferably, the excitation coil is configured as a non-helical, semi-cylindrical conductive surface having less than one turn, in the general shape of a wedding ring. At high frequencies, the current in the coil forms two loops which are spaced apart and parallel to each other. Configured appropriately, the coil approximates a Helmholtz configuration. The lamp preferably utilizes an bulb encased in a reflective ceramic cup with a pre-formed aperture defined therethrough. The ceramic cup may include structural features to aid in alignment and/or a flanged face to aid in thermal management. The lamp head is preferably an integrated lamp head comprising a metal matrix composite surrounding an insulating ceramic with the excitation integrally formed on the ceramic. A novel solid-state oscillator preferably provides RF power to the lamp. The oscillator is a single active element device capable of providing over 70 watts of power at over 70% efficiency. Various control circuits may be employed to match the driving frequency of the oscillator to a plurality of tuning states of the lamp.

MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD); Dolan, James T. (Frederick, MD); Kirkpatrick, Douglas A. (Great Falls, VA); Leng, Yongzhang (Damascus, MD)

2000-01-01T23:59:59.000Z

73

Long-Term Performance of Screwbase Compact Fluorescent Lamps  

Science Conference Proceedings (OSTI)

The packaging material for compact fluorescent lamps normally includes some claim regarding expected lamp lifetime. This claimed lifetime is generally not obtained through rigorous testing. This study shows how different operating cycles, components, and lamp and ballast designs affect screwbase compact fluorescent lamp (SCFL) life.

2000-04-11T23:59:59.000Z

74

Energy Basics: Incandescent Lighting  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

The three most common types of incandescent lamps are: Standard incandescent lamps Energy-Saving Incandescent (or Halogen) Reflector lamps Standard Incandescent Lamps Known as...

75

Buildings Energy Data Book: 7.6 Efficiency Standards for Lighting  

Buildings Energy Data Book (EERE)

1 1 Efficiency Standards for General Service Fluorescent Lamps Effective for products manufactured before July 14, 2012 Minimum Nominal Lamp Average Lamp Lamp Type (1) Wattage (W) Minimum CRI Efficacy (lm/W) Effective Date 4-Foot Medium Bipin >35 69 75.0 November 1, 1995 4-Foot Medium Bipin ≤35 45 75.0 November 1, 1995 2-Foot U-Shaped >35 69 68.0 November 1, 1995 2-Foot U-Shaped ≤35 45 64.0 November 1, 1995 8-Foot Slimline >65 69 80.0 May 1, 1994 8-Foot Slimline ≤65 45 80.0 May 1, 1994 8-Foot High Output >100 69 80.0 May 1, 1994 8-Foot High Output ≤100 45 80.0 May 1, 1994 Effective for products manufactured on or after July 14, 2012 Minimum Correlated Color Average Lamp Lamp Type Temperature (K) Efficacy (lm/W) 4-Foot Medium Bipin ≤4,500 89 4-Foot Medium Bipin >4,500 and ≤7,000 88

76

Demonstration of LED Retrofit Lamps at the Jordan Schnitzer Museum of Art  

SciTech Connect

The Jordan Schnitzer Museum of Art in Eugene, Oregon, houses a remarkable permanent collection of Asian art and antiquities, modern art, and sculpture, and also hosts traveling exhibitions. In the winter and spring of 2011, a series of digital photographs by artist Chris Jordan, titled "Running the Numbers," was exhibited in the Coeta and Donald Barker Special Exhibitions Gallery. These works graphically illustrate waste (energy, money, health, consumer objects, etc.) in contemporary culture. The Bonneville Power Administration and the Eugene Water and Electricity Board provided a set of Cree 12W light-emitting diode (LED) PAR38 replacement lamps (Cree LRP38) for the museum to test for accent lighting in lieu of their standard Sylvania 90W PAR38 130V Narrow Flood lamps (which draw 78.9W at 120V). At the same time, the museum tested LED replacement lamps from three other manufacturers, and chose the Cree lamp as the most versatile and most appropriate color product for this exhibit. The lamps were installed for the opening of the show in January 2011. This report describes the process for the demonstration, the energy and economic results, and results of a survey of the museum staff and gallery visitors on four similar clusters of art lighted separately by four PAR38 lamps.

Miller, Naomi J.

2011-09-01T23:59:59.000Z

77

EA-1911: Energy Conservation Standards for Certain Reflector...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1: Energy Conservation Standards for Certain Reflector, Elliptical Reflector, and Bulged Reflector Incandescent Lamps EA-1911: Energy Conservation Standards for Certain Reflector,...

78

Max Tech and Beyond: Fluorescent Lamps  

Science Conference Proceedings (OSTI)

Fluorescent lamps are the most widely used artificial light source today, responsible for approximately 70% of the lumens delivered to our living spaces globally. The technology was originally commercialized in the 1930's, and manufacturers have been steadily improving the efficacy of these lamps over the years through modifications to the phosphors, cathodes, fill-gas, operating frequency, tube diameter and other design attributes. The most efficient commercially available fluorescent lamp is the 25 Watt T5 lamp. This lamp operates at 114-116 lumens per watt while also providing good color rendering and more than 20,000 hours of operating life. Industry experts interviewed indicated that while this lamp is the most efficient in the market today, there is still a further 10 to 14% of potential improvements that may be introduced to the market over the next 2 to 5 years. These improvements include further developments in phosphors, fill-gas, cathode coatings and ultraviolet (UV) reflective glass coatings. The commercialization of these technology improvements will combine to bring about efficacy improvements that will push the technology up to a maximum 125 to 130 lumens per watt. One critical issue raised by researchers that may present a barrier to the realization of these improvements is the fact that technology investment in fluorescent lamps is being reduced in order to prioritize research into light emitting diodes (LEDs) and ceramic metal halide high intensity discharge (HID) lamps. Thus, it is uncertain whether these potential efficacy improvements will be developed, patented and commercialized. The emphasis for premium efficacy will continue to focus on T5 lamps, which are expected to continue to be marketed along with the T8 lamp. Industry experts highlighted the fact that an advantage of the T5 lamp is the fact that it is 40% smaller and yet provides an equivalent lumen output to that of a T8 or T12 lamp. Due to its smaller form factor, the T5 lamp contains less material (i.e., glass, fill gas and phosphor), and has a higher luminance, enabling fixtures to take advantage of the smaller lamp size to improve the optics and provide more efficient overall system illuminance. In addition to offering the market a high-quality efficacious light source, another strong value proposition of fluorescent lighting is its long operating life. In today's market, one manufacturer is offering fluorescent lamps that have a rated life of 79,000 hours - which represents 18 years of service at 12 hours per day, 365 days per year. These lamps, operated using a long-life ballast specified by the manufacturer, take advantage of improvements in cathode coatings, fill gas chemistry and pressure to extend service life by a factor of four over conventional fluorescent lamps. It should be noted that this service life is also longer (approximately twice as long) as today's high-quality LED products. The fluorescent market is currently focused on the T5 and T8 lamp diameters, and it is not expected that other diameters would be introduced. Although T8 is a more optimal diameter from an efficacy perspective, the premium efficiency and optimization effort has been focused on T5 lamps because they are 40% smaller than T8, and are designed to operate at a higher temperature using high-frequency electronic ballasts. The T5 lamp offers savings in terms of materials, packaging and shipping, as well as smaller fixtures with improved optical performance. Manufacturers are actively researching improvements in four critical areas that are expected to yield additional efficacy improvements of approximately 10 to 14 percent over the next five years, ultimately achieving approximately 130 lumens per watt by 2015. The active areas of research where these improvements are anticipated include: (1) Improved phosphors which continue to be developed and patented, enabling higher efficacies as well as better color rendering and lumen maintenance; (2) Enhanced fill gas - adjusting proportions of argon, krypton, neon and xenon to optimize performance, while also m

Scholand, Michael

2012-04-01T23:59:59.000Z

79

High frequency inductive lamp and power oscillator  

DOE Patents (OSTI)

A high frequency inductively coupled electrodeless lamp includes an excitation coil with an effective electrical length which is less than one half wavelength of a driving frequency applied thereto, preferably much less. The driving frequency may be greater than 100 MHz and is preferably as high as 915 MHz. Preferably, the excitation coil is configured as a non-helical, semi-cylindrical conductive surface having less than one turn, in the general shape of a wedding ring. At high frequencies, the current in the coil forms two loops which are spaced apart and parallel to each other. Configured appropriately, the coil approximates a Helmholtz configuration. The lamp preferably utilizes an bulb encased in a reflective ceramic cup with a pre-formed aperture defined therethrough. The ceramic cup may include structural features to aid in alignment and I or a flanged face to aid in thermal management. The lamp head is preferably an integrated lamp head comprising a metal matrix composite surrounding an insulating ceramic with the excitation integrally formed on the ceramic. A novel solid-state oscillator preferably provides RF power to the lamp. The oscillator is a single active element device capable of providing over 70 watts of power at over 70% efficiency. Various control circuits may be employed to adjust the driving frequency of the oscillator.

MacLennan, Donald A. (Gaithersburg, MD); Dymond, Jr., Lauren E. (North Potomac, MD); Gitsevich, Aleksandr (Montgomery Village, MD); Grimm, William G. (Silver Spring, MD); Kipling, Kent (Gaithersburg, MD); Kirkpatrick, Douglas A. (Great Falls, VA); Ola, Samuel A. (Silver Spring, MD); Simpson, James E. (Gaithersburg, MD); Trimble, William C. (Columbia, MD); Tsai, Peter (Olney, MD); Turner, Brian P. (Damascus, MD)

2001-01-01T23:59:59.000Z

80

Realized and Projected Impacts of U.S. Energy Efficiency Standards for Residential and Commercial Appliances  

E-Print Network (OSTI)

1989). Lamp Efficiency Standards for Massachusetts: AnalysisDocuments for DOE Energy Efficiency Standards 1. U.S.Office of Codes and Standards, Technical Support Document:

Meyers, Stephen P.

2008-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "lamp type standard" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Land Disposal Restrictions Treatment Standards: Compliance Strategies for Four Types of Mixed Wastes  

Science Conference Proceedings (OSTI)

This paper describes the unique challenges involved in achieving compliance with the Resource Conservation and Recovery Act (Public Law 94-580) Land Disposal Restrictions (LDR) treatment standards for four types of mixed wastes generated throughout the U.S. Department of Energy (DOE) complex: (1) radioactively contaminated lead acid batteries; (2) radioactively contaminated cadmium-, mercury-, and silver-containing batteries; (3) mercury-bearing mixed wastes; and (4) radioactive lead solids. For each of these mixed waste types, the paper identifies the strategy pursued by DOE's Office of Pollution Prevention and Resource Conservation Policy and Guidance (EH-43) in coordination with other DOE elements and the U.S. Environmental Protection Agency (EPA) to meet the compliance challenge. Specifically, a regulatory interpretation was obtained from EPA agreeing that the LDR treatment standard for wastes in the D008 'Radioactive Lead Solids' sub-category applies to radioactively contaminated lead acid batteries. For cadmium-, mercury-, and silver-containing batteries, generically applicable treatability variances were obtained from EPA approving macro-encapsulation as the alternative LDR treatment standard for all three battery types. Joint DOE/EPA technology demonstrations were pursued for mercury-bearing mixed wastes in an effort to justify revising the LDR treatment standards, which focus on thermal recovery of mercury for reuse. Because the demonstrations failed to produce enough supporting data for a rulemaking, however, EPA has recommended site-specific treatability variances for particular mercury-bearing mixed waste streams. Finally, DOE has filed an application for a determination of equivalent treatment requesting approval of container-based macro-encapsulation technologies as an alternative LDR treatment standard for radioactive lead solids. Information is provided concerning the length of time required to implement each of these strategies, and suggestions for obtaining variances from the LDR treatment standards at the site-specific level are also discussed. (authors)

Fortune, W.B. [U.S, Department of Energy, Office of Pollution Prevention and Resource Conservation (EH-43), 1000 Independence Ave., S.W., Washington, DC 20585 (United States); Ranek, N.L. [Argonne National Laboratory, Environmental Science Division, 955 L'Enfant Plaza North, Suite 6000, Washington, DC 20024 (United States)

2006-07-01T23:59:59.000Z

82

High frequency electronic ballast for HID lamps. Technical progress report, October 1, 1993--December 31, 1994  

SciTech Connect

Electronic Ballast Systems Corp. has been working on the development of highly efficient (94%) electronic ballast for HID lamps (35W,...,400W) providing energy savings of up to thirty five percent (35%) as compared to the only available alternative, the standard core and coil HID ballasts currently on the market.

1995-03-01T23:59:59.000Z

83

EA-1881: Energy Conservation Program: Energy Conservation Standards for  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

81: Energy Conservation Program: Energy Conservation Standards 81: Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts EA-1881: Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts Summary This EA evaluates the environmental impacts of a proposal to amend energy conservation standards for various consumer products and certain commercial and industrial equipment, including fluorescent lamp ballasts. Public Comment Opportunities No public comment opportunities available at this time. Documents Available for Download October 20, 2011 EA-1881: Finding of No Significant Impact Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts (October 2011) October 5, 2011 EA-1881: Final Environmental Assessment Energy Conservation Program: Energy Conservation Standards for Fluorescent

84

Energy Performance of Compact Fluorescent Lamps  

Science Conference Proceedings (OSTI)

This power quality (PQ) case study presents the results of tests performed at the Worcester Polytechnic Institute, in contract with the EPRI Power Electronics Applications Center (PEAC), to determine the light output, power consumption, efficiency, and power factor of off-the-shelf electronic and magnetic compact fluorescent lamps.

2003-12-31T23:59:59.000Z

85

Laboratory Evaluation of LED T8 Replacement Lamp Products  

Science Conference Proceedings (OSTI)

A report on a lab setting analysis involving LED lamps intended to directly replace T8 fluorescent lamps (4') showing light output, power, and economic comparisons with other fluorescent options.

Richman, Eric E.; Kinzey, Bruce R.; Miller, Naomi J.

2011-05-23T23:59:59.000Z

86

The Effects of Table Lamp Shade Shape and Compact Fluorescent...  

NLE Websites -- All DOE Office Websites (Extended Search)

The Effects of Table Lamp Shade Shape and Compact Fluorescent Lamp Burning Position on Visual Comfort Speaker(s): Zaidi Abdullah Date: March 15, 2001 - 12:00pm Location: Bldg. 90...

87

Light Flicker in Compact Fluorescent Lamps Caused by Voltage Fluctuations  

Science Conference Proceedings (OSTI)

This power quality (PQ) case study presents tests performed at the EPRI Power Electronics Applications Center (PEAC) Power Quality Test Facility to characterize the light output of an incandescent lamp and compact fluorescent lamps during voltage fluctuations.

2003-12-31T23:59:59.000Z

88

Energy-Efficient, High-Color-Rendering LED Lamps Using Oxyfluoride and Fluoride Phosphors  

Science Conference Proceedings (OSTI)

LED lamps using phosphor downconversion can be designed to replace incandescent or halogen sources with a 'warm-white' correlated color temperature (CCT) of 2700-3200 K and a color rendering index (CRI) greater than 90. However, these lamps have efficacies of {approx}70% of standard 'cool-white' LED packages (CCT = 4500-6000 K; CRI = 75-80). In this report, we describe structural and luminescence properties of fluoride and oxyfluoride phosphors, specifically a (Sr,Ca){sub 3}(Al,Si)O{sub 4}(F,O):Ce{sup 3+} yellow-green phosphor and a K{sub 2}TiF{sub 6}:Mn{sup 4+} red phosphor, that can reduce this gap and therefore meet the spectral and efficiency requirements for high-efficacy LED lighting. LED lamps with a warm-white color temperature (3088 K), high CRI (90), and an efficacy of {approx}82 lm/W are demonstrated using these phosphors. This efficacy is {approx}85% of comparable cool-white lamps using typical Y{sub 3}Al{sub 5}O{sub 12}:Ce{sup 3+}-based phosphors, significantly reducing the efficacy gap between warm-white and cool-white LED lamps that use phosphor downconversion.

Setlur, A.; Radkov, E; Henderson, C; Her, J; Srivastava, A; Karkada, N; Kishore, M; Kumar, N; Aesram, D; et al.

2010-01-01T23:59:59.000Z

89

Magical Mystery Devices or Not: How do LED Lamps and Luminaires Really Measure-Up?  

SciTech Connect

Solid-state lighting products for general lighting applications are now gaining a market presence, and more and more people are asking, Which of these are good products? Do they perform as claimed? How do they compare? Light Emitting Diodes (LEDs) differ from other light sources enough to require new procedures for measuring their performance and comparing to other lighting options, so both manufacturers and buyers are facing a learning curve. The energy-efficiency community has traditionally compared light sources based on system efficacy: rated lamp lumens divided by power into the system. This doesnt work for LEDs because there are no standard LED lamp packages and no lamp ratings, and because LED performance depends heavily on thermal, electrical, and optical design of complete lighting unit or luminaire. Luminaire efficacy is the preferred metric for LEDs because it measures the net light output from the luminaire divided by power into the system.

Paget, Maria L.; McCullough, Jeffrey J.; Steward, Heidi E.

2008-08-15T23:59:59.000Z

90

Novel Nanophosphors for High Efficiency Fluorescent Lamps  

SciTech Connect

This is the Final Report of the Novel Nanophosphors for High Efficiency Fluorescent Lamps, Department of Energy (DOE). The overall goal of this three-year program is to develop novel hybrid phosphors by coating commercially available lamp phosphors with highly stable wide band-gap nanocrystalline phosphors (NCP). The prime technical approach is the development of NCP quantum-splitting phosphor (QSP) and ultra-violet (UV) emitting phosphors with quantum efficiencies exceeding that of the conventional phosphors at 185 nm. The novel hybrid phosphors will increase the efficiency of the fluorescent lamps by up to 32%, enabling total energy savings of 0.26 quads, the reduction in the U.S. energy bill by $6.5 billion and the reduction of the annual carbon emission by 4.1 billion kilogram. Our work started by investigating through modeling calculations the requirement for the particle size of the NCP. Our work to develop suitable nanocrystalline phosphors started with the known oxide quantum splitting and UV emitting phosphors. We demonstrated several synthesis techniques for the production of high quality nanocrystalline materials that crystallizes in the desired phase and with the desired particle size. In collaboration with our subcontractor we demonstrated the feasibility for the manufacture of NC phosphors. We also demonstrated novel techniques of coating the NCP on the surface of micron sized phosphors. Our chief achievement pertains to the successful testing of the coated hybrid phosphor systems in linear fluorescent lamps. In linear fluorescent lamp tests, we have demonstrated up to 7% increase in the efficacy of hybrid phosphors over the conventional (uncoated) phosphors. We have also demonstrated the improvement in the lumen maintenance of the coated phosphors. A hybrid phosphor system based on the commercial red emitting phosphor, Y{sub 2}O{sub 3}:Eu{sup 3+} did not show the anticipated improvement in lamp efficacy. We explored the reasons for this observation, which are detailed in this report. Within the program we have carried out fundamental investigations into the physical processes that determine the quantum splitting behavior of the Pr{sup 3+} ion in solids. Specifically, we have investigated the quantum splitting luminescence of this ion in the LaPO{sub 4}, SrAl{sub 12}O{sub 19} and LiLaP{sub 4}O{sub 12} host lattices. In this final report we summarize the technical work completed under the Program, summarize our findings about the performance limits of the various technologies we investigated, and outline promising paths for future work.

Alok Srivatava

2007-03-31T23:59:59.000Z

91

Controlling the vapor pressure of a mercury lamp  

DOE Patents (OSTI)

The invention described herein discloses a method and apparatus for controlling the Hg vapor pressure within a lamp. This is done by establishing and controlling two temperature zones within the lamp. One zone is colder than the other zone. The first zone is called the cold spot. By controlling the temperature of the cold spot, the Hg vapor pressure within the lamp is controlled. Likewise, by controlling the Hg vapor pressure of the lamp, the intensity and linewidth of the radiation emitted from the lamp is controlled. 2 figs.

Grossman, M.W.; George, W.A.

1988-05-24T23:59:59.000Z

92

Controlling the vapor pressure of a mercury lamp  

DOE Patents (OSTI)

The invention described herein discloses a method and apparatus for controlling the Hg vapor pressure within a lamp. This is done by establishing and controlling two temperature zones within the lamp. One zone is colder than the other zone. The first zone is called the cold spot. By controlling the temperature of the cold spot, the Hg vapor pressure within the lamp is controlled. Likewise, by controlling the Hg vapor pressure of the lamp, the intensity and linewidth of the radiation emitted from the lamp is controlled.

Grossman, Mark W. (Belmont, MA); George, William A. (Rockport, MA)

1988-01-01T23:59:59.000Z

93

LED lamp color control system and method  

DOE Patents (OSTI)

An LED lamp color control system and method including an LED lamp having an LED controller 58; and a plurality of LED channels 60 operably connected to the LED controller 58, each of the plurality of LED channels 60 having a channel switch 62 in series with at least one shunted LED circuit 83, the shunted LED circuit 83 having a shunt switch 68 in parallel with an LED source 80. The LED controller 58 determines whether the LED source 80 is in a feedback controllable range, stores measured optical flux for the LED source 80 when the LED source 80 is in the feedback controllable range, and bypasses storing the measured optical flux when the LED source 80 is not in the feedback controllable range.

Gaines, James; Clauberg, Bernd; Van Erp, Josephus A.M.

2013-02-05T23:59:59.000Z

94

Lamp method and apparatus using multiple reflections  

DOE Patents (OSTI)

A method wherein the light in a sulfur or selenium lamp is reflected through the fill a multiplicity of times to convert ultraviolet radiation to visible is disclosed. A light emitting device comprised of an electrodeless envelope which bears a light reflecting covering around a first portion which does not crack due to differential thermal expansion and which has a second portion which comprises a light transmissive aperture. 20 figs.

MacLennan, D.A.; Turner, B.; Kipling, K.

1999-05-11T23:59:59.000Z

95

Lamp method and apparatus using multiple reflections  

DOE Patents (OSTI)

A method wherein the light in a sulfur or selenium lamp is reflected through the fill a multiplicity of times to convert ultraviolet radiation to visible. A light emitting device comprised of an electrodeless envelope which bears a light reflecting covering around a first portion which does not crack due to differential thermal expansion and which has a second portion which comprises a light transmissive aperture.

MacLennan, Donald A. (Butler, PA); Turner, Brian (Damascus, MD); Kipling, Kent (Gaithersburg, MD)

1999-01-01T23:59:59.000Z

96

Spectral distribution of dimmed HID lamps in a plant growth facility  

SciTech Connect

A commercial dimming ballast system for high intensity discharge (HID) lamps has been tested for use in plant growth chambers. The dimming ballast system can be controlled either manually at the dimming panel or by a d.c. voltage from a programmer or computer. Using the dimming system, photosynthetically active radiation can be continuously varied from about 200 to about 2000 ..mu..E m/sup -2/s/sup -1/. This paper shows the effects of dimming on the spectral intensity (400 to 750 nm) of three types of HID lamps measured individually and in combination to achieve a better spectral mix. The lamps used in this study were 400 w metal halide, mercury vapor and high pressure sodium.

Bingham, G.E.; Coyne, P.I.

1979-05-01T23:59:59.000Z

97

High output lamp with high brightness  

DOE Patents (OSTI)

An ultra bright, low wattage inductively coupled electrodeless aperture lamp is powered by a solid state RF source in the range of several tens to several hundreds of watts at various frequencies in the range of 400 to 900 MHz. Numerous novel lamp circuits and components are disclosed including a wedding ring shaped coil having one axial and one radial lead, a high accuracy capacitor stack, a high thermal conductivity aperture cup and various other aperture bulb configurations, a coaxial capacitor arrangement, and an integrated coil and capacitor assembly. Numerous novel RF circuits are also disclosed including a high power oscillator circuit with reduced complexity resonant pole configuration, parallel RF power FET transistors with soft gate switching, a continuously variable frequency tuning circuit, a six port directional coupler, an impedance switching RF source, and an RF source with controlled frequency-load characteristics. Numerous novel RF control methods are disclosed including controlled adjustment of the operating frequency to find a resonant frequency and reduce reflected RF power, controlled switching of an impedance switched lamp system, active power control and active gate bias control.

Kirkpatrick, Douglas A. (Great Falls, VA); Bass, Gary K. (Mt. Airy, MD); Copsey, Jesse F. (Germantown, MD); Garber, Jr., William E. (Poolesville, MD); Kwong, Vincent H. (Vancouver, CA); Levin, Izrail (Silver Spring, MD); MacLennan, Donald A. (Gaithersburg, MD); Roy, Robert J. (Frederick, MD); Steiner, Paul E. (Olney, MD); Tsai, Peter (Olney, MD); Turner, Brian P. (Damascus, MD)

2002-01-01T23:59:59.000Z

98

High Efficiency LED Lamp for Solid-State Lighting  

SciTech Connect

This report contains a summary of technical achievements during a three-year project to demonstrate high efficiency, solid-state lamps based on gallium nitride/silicon carbide light-emitting diodes. Novel chip designs and fabrication processes are described for a new type of nitride light-emitting diode with the potential for very high efficiency. This work resulted in the demonstration of blue light-emitting diodes in the one watt class that achieved up to 495 mW of light output at 350 mA drive current, corresponding to quantum and wall plug efficiencies of 51% and 45%, respectively. When combined with a phosphor in Cree's 7090 XLamp package, these advanced blue-emitting devices resulted in white light-emitting diodes whose efficacy exceeded 85 lumens per watt. In addition, up to 1040 lumens at greater than 85 lumens per watt was achieved by combining multiple devices to make a compact white lamp module with high optical efficiency.

James Ibbetson

2006-12-31T23:59:59.000Z

99

High intensity discharge lamp self-adjusting ballast system sensitive to the radiant energy or heat of the lamp  

SciTech Connect

This patent describes a self-adjusting ballast system for mercury vapor, high intensity discharge lamps having outputs of 100 watts or greater, comprising: a direct current source; a lamp circuit containing a high intensity discharge lamp; sensing means for sensing the radiant energy output of the lamp; a pulse width modulator which, in response to the output of the sensing means, varies the width of the pulses that power the lamp during warm-up of the lamp; a high frequency oscillator; a DC to AC converter that converts current from the direct source to pulses of alternating current for powering the lamp, the converter comprising: at least one switch for gating current to the lamp; a switch control means, responsive to the high frequency oscillator, for controlling the switch and controlling the frequency of the alternating current pulses that power the lamp; current sensing means for sensing the current being supplied to the lamp; and current control means for limiting the current through the lamp to a predetermined safe level when the current sensed by the current sensing means exceeds a reference value.

Kuhnel, D.S.; Ottenstein, S.A.

1987-07-21T23:59:59.000Z

100

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Metal Halide Lamp Fixtures Energy Conservation Standard Metal Halide Lamp Fixtures Energy Conservation Standard Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) is considering establishing new and amended energy conservation standards for metal halide lamp fixtures (MHLF). This activity is mandated by the Energy Policy and Conservation Act (42 U.S.C. 6291-6309 seq). Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a notice of proposed rulemaking regarding energy conservation standards for metal halide lamp fixtures. 78 FR 51463 (August 20, 2013). Public Meeting Information A public meeting was held on September 27, 2013.

Note: This page contains sample records for the topic "lamp type standard" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Light Emitting Diode Lamps Sign up for e-mail updates on regulations for this and other products There are currently no energy conservation standards for light emitting diode (LED)...

102

NIST Global Standards Information WTO TBT Inquiry Point  

Science Conference Proceedings (OSTI)

... Standards & Trade >; WTO TBT Inquiry Point >; US Notifications >. US Notifications. United States of America (USA/698: Light-emitting diode lamps). ...

103

Hybrid electronic ballast operating the HPS lamp at constant power  

SciTech Connect

A hybrid solid-state ballast that operates high-pressure sodium (HPS) lamps at main frequency with constant power through rated life is described. The system utilizes two inductors connected in series and a bidirectional semiconductor switch connected in parallel to one of them. A lamp-starting circuit has also been included in the ballast. The static switch, with phase angle control provided by power feedback, actuates on lamp current compensating variations of the main voltage and increases of lamp arc voltage. The system offers the following: (1) increase of lamp life and system lumen maintenance; (2) power factor and total harmonic distortion of line current comparable to conventional lag ballast; and (3) operating cost savings, both in terms of energy cost and lamp replacement cost.

Kaiser, W. [Univ. de Sao Paulo (Brazil)

1998-03-01T23:59:59.000Z

104

Compact microwave lamp having a tuning block and a dielectric located in a lamp cavity  

DOE Patents (OSTI)

A microwave lamp having a compact structure utilizing a coupling slot which has a dielectric member extending therethrough and a tuning block adjoining the coupling slot. A non-conventional waveguide is used which has about the width of a WR-284 waveguide and about the length of a WR-340 waveguide.

Simpson, James E. (Gaithersburg, MD)

2000-01-01T23:59:59.000Z

105

LED LAMP OR BULB WITH REMOTE PHOSPHOR AND DIFFUSER ...  

An LED lamp or bulb is disclosed that comprises a light source, a heat sink structure and an optical cavity. The optical cavity comprises a phosphor ...

106

Heat transfer assembly for a fluorescent lamp and fixture  

DOE Patents (OSTI)

In a lighting fixture including a lamp and a housing, a heat transfer structure is disclosed for reducing the minimum lamp wall temperature of a fluorescent light bulb. The heat transfer structure, constructed of thermally conductive material, extends from inside the housing to outside the housing, transferring heat energy generated from a fluorescent light bulb to outside the housing where the heat energy is dissipated to the ambient air outside the housing. Also disclosed is a method for reducing minimum lamp wall temperatures. Further disclosed is an improved lighting fixture including a lamp, a housing and the aforementioned heat transfer structure. 11 figs.

Siminovitch, M.J.; Rubenstein, F.M.; Whitman, R.E.

1992-12-29T23:59:59.000Z

107

Fluorescent lamp unit with magnetic field generating means  

DOE Patents (OSTI)

A fluorescent lamp unit having a magnetic field generating means for improving the performance of the fluorescent lamp is disclosed. In a preferred embodiment the fluorescent lamp comprises four longitudinally extending leg portions disposed in substantially quadrangular columnar array and joined by three generally U-shaped portions disposed in different planes. In another embodiment of the invention the magnetic field generating means comprises a plurality of permanent magnets secured together to form a single columnar structure disposed within a centrally located region defined by the shape of lamp envelope. 4 figs.

Grossman, M.W.; George, W.A.

1989-08-08T23:59:59.000Z

108

Development and characterization of a high CRI LED lamp.  

E-Print Network (OSTI)

??The aim of this thesis is to realize a high CRI LED lamp using the color mixing technique. We start from a high efficiency white (more)

Meneghesso , Matteo

2012-01-01T23:59:59.000Z

109

Heat transfer assembly for a fluorescent lamp and fixture  

DOE Patents (OSTI)

In a lighting fixture including a lamp and a housing, a heat transfer structure is disclosed for reducing the minimum lamp wall temperature of a fluorescent light bulb. The heat transfer structure, constructed of thermally conductive material, extends from inside the housing to outside the housing, transferring heat energy generated from a fluorescent light bulb to outside the housing where the heat energy is dissipated to the ambient air outside the housing. Also disclosed is a method for reducing minimum lamp wall temperatures. Further disclosed is an improved lighting fixture including a lamp, a housing and the aforementioned heat transfer structure.

Siminovitch, Michael J. (Richmond, CA); Rubenstein, Francis M. (Berkeley, CA); Whitman, Richard E. (Richmond, CA)

1992-01-01T23:59:59.000Z

110

Fluorescent lamp with static magnetic field generating means  

DOE Patents (OSTI)

A fluorescent lamp wherein magnetic field generating means (e.g., permanent magnets) are utilized to generate a static magnetic field across the respective electrode structures of the lamp such that maximum field strength is located at the electrode's filament. An increase in efficacy during operation has been observed. 2 figs.

Moskowitz, P.E.; Maya, J.

1987-09-08T23:59:59.000Z

111

Fluorescent lamp with static magnetic field generating means  

DOE Patents (OSTI)

A fluorescent lamp wherein magnetic field generating means (e.g., permanent magnets) are utilized to generate a static magnetic field across the respective electrode structures of the lamp such that maximum field strength is located at the electrode's filament. An increase in efficacy during operation has been observed.

Moskowitz, Philip E. (Peabody, MA); Maya, Jakob (Brookline, MA)

1987-01-01T23:59:59.000Z

112

An Electrical Cathode Model of a High Pressure Sodium Lamp  

Science Conference Proceedings (OSTI)

An electrical cathode model (ECM) of a high pressure sodium lamp (HPS) based on physical laws has been developed. The proposed ECM calculates the instantaneous voltage drop in a cathode sheath and the temperature distribution inside the cathode using ... Keywords: cathode model, HPS lamp ballast designs

Jose Luis Tapia; Joel O. Pacheco Sotelo; Eduardo Diaz Rodriguez; Yulia Nikolaevna Ledeneva; Rene Arnulfo Garcia Hernandez

2010-09-01T23:59:59.000Z

113

DEFINING THE EFFECTIVENESS OF UV LAMPS  

Office of Scientific and Technical Information (OSTI)

ARTI-21CR/610-40030-01 ARTI-21CR/610-40030-01 DEFINING THE EFFECTIVENESS OF UV LAMPS INSTALLED IN CIRCULATING AIR DUCTWORK Final Report Date Published - November 2002 Douglas VanOsdell and Karin Foarde RTI P.O. Box 12194 Research Triangle Park, NC 27709-2194 Prepared for the AIR-CONDITIONING AND REFRIGERATION TECHNOLOGY INSTITUTE 4100 N. Fairfax Drive, Suite 200, Arlington, Virginia 22203 Distribution A - Approved for public release; further dissemination unlimited. DISCLAIMER This report was prepared as an account of work sponsored by the Air-Conditioning and Refrigeration Technology Institute (ARTI) under its "HVAC&R Research for the 21 st Century" (21-CR) program. Neither ARTI, the financial supporters of the 21-CR program, or any agency

114

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

General Service Fluorescent Lamps General Service Fluorescent Lamps Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of general service fluorescent lamps (GSFLs) since 1994. GSFLs are fluorescent tubes with pins at one or both ends for installation. These lamps are generally installed in ceilings. Recent Updates | Standards | Test Procedures | Waiver, Exception, and Exemption Information | Statutory Authority | Historical Information | Contact Information Recent Updates DOE published a notice of public meeting and availability of preliminary technical support document regarding energy conservation standards for GSFLs. 78 FR 13563 (February 28, 2013). DOE later published a notice of correction. 78 FR 14467 (March 6, 2013). For more information, please see the rulemaking webpage.

115

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

General Service Incandescent Lamps General Service Incandescent Lamps Sign up for e-mail updates on regulations for this and other products Manufacturers have been required to comply with the Department of Energy's (DOE) energy conservation standards for general service incandescent lamps (GSILs) since 2012. Most GSILs are the pear-shaped, screw-in light bulbs found in most homes. Most GSILs are currently sold as one of four wattages: 40, 60, 75, and 100. Starting in 2012, these will be replaced by more efficient lower wattage lamps. Recent Updates | Standards | Test Procedures | Waiver, Exception, and Exemption Information | Statutory Authority | Historical Information | Contact Information Recent Updates DOE published a final rule updating the test procedures for GSILs. 77 FR 4203 (Jan. 27, 2012).

116

Contrast between the vertical and horizontal mercury discharge lamps  

SciTech Connect

This paper discusses the thermal behavior of a high pressure mercury lamp in a horizontal position, compared with that of a vertical lamp. The model adopted is three-dimensional, steady, and powered DC. After the model validation, we analyzed temperature fields and velocities for the case of the lamp in a horizontal position by comparing it with those of a lamp in vertical position. This setting initially fixed the wall temperature equal to 1000 K. However, the morphology of the temperature profile in the case of the horizontal lamp indicates that the temperature of the wall cannot be uniform. Thus, we have, in a second time, performed an energy balance at the wall to calculate its temperature. This aims to understand the influence of convection on the thermal properties of the source.

Ben Hamida, M. B.; Helali, H.; Araoud, Z.; Charrada, K. [Unite d'Etude des Milieux Ionises et Reactifs, IPEIM, 5019 route de Kairouan Monastir (Tunisia)

2011-06-15T23:59:59.000Z

117

Highly Efficient Small Form Factor LED Retrofit Lamp  

SciTech Connect

This report summarizes work to develop a high efficiency LED-based MR16 lamp downlight at OSRAM SYLVANIA under US Department of Energy contract DE-EE0000611. A new multichip LED package, electronic driver, and reflector optic were developed for these lamps. At steady-state, the lamp luminous flux was 409 lumens (lm), luminous efficacy of 87 lumens per watt (LPW), CRI (Ra) of 87, and R9 of 85 at a correlated color temperature (CCT) of 3285K. The LED alone achieved 120 lumens per watt efficacy and 600 lumen flux output at 25 C. The driver had 90% electrical conversion efficiency while maintaining excellent power quality with power factor >0.90 at a power of only 5 watts. Compared to similar existing MR16 lamps using LED sources, these lamps had much higher efficacy and color quality. The objective of this work was to demonstrate a LED-based MR16 retrofit lamp for replacement of 35W halogen MR16 lamps having (1) luminous flux of 500 lumens, (2) luminous efficacy of 100 lumens per watt, (3) beam angle less than 40{sup o} and center beam candlepower of at least 1000 candelas, and (4) excellent color quality.

Steven Allen; Fred Palmer; Ming Li

2011-09-11T23:59:59.000Z

118

Lamp method and apparatus using multiple reflections  

DOE Patents (OSTI)

An electrodeless microwave discharge lamp includes an envelope with a discharge forming fill disposed therein which emits light, the fill being capable of absorbing light at one wavelength and re-emitting the absorbed light at a different wavelength, the light emitted from the fill having a first spectral power distribution in the absence of reflection of light back into the fill, a source of microwave energy coupled to the fill to excite the fill and cause the fill to emit light, and a reflector disposed within the microwave cavity and configured to reflect at least some of the light emitted by the fill back into the fill while allowing some light to exit, the exiting light having a second spectral power distribution with proportionately more light in the visible region as compared to the first spectral power distribution, wherein the light re-emitted by the fill is shifted in wavelength with respect to the absorbed light and the magnitude of the shift is in relation to an effective optical path length.

MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD)

2001-01-01T23:59:59.000Z

119

Experimental methodology for determining the system performance of fluorescent lamp, ballast, fixture combinations operating under realistic application conditions  

SciTech Connect

To meet the need for accurate performance data, an experimental method for determining the performance of lamp, ballast, and luminaire combinations operating under a broad range of realistic conditions was developed. The methodology employs a two-part experimental procedure. The first part uses a temperature-controlled luminous flux integrator to characterize the thermal performance of each lamp/ballast combination. This performance characterization is expressed in terms of light output and efficacy as a function of variations in minimum lamp wall temperature (MLWT) and is generated for the range of temperatures typically encountered in interior lighting applications. The second procedure uses a luminaire/plenum simulator to determine the specific MLWT that exists in a particular luminaire application as a function of luminaire type, mounting configuration, plenum integration, and room air temperature. The MLWTs thus measured may be used in conjunction with the lamp/ballast performance data to determine application-specific values of light output and efficacy for a given lamp/ballast/luminaire system.

Siminovitch, M.J.; Rubinstein, F.M.; Verderber, R.R.

1984-11-01T23:59:59.000Z

120

Covered Product Category: Compact Fluorescent Lamps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Covered Product Category: Compact Fluorescent Lamps Covered Product Category: Compact Fluorescent Lamps Covered Product Category: Compact Fluorescent Lamps October 7, 2013 - 10:48am Addthis ENERGY STAR Qualified Products Federal Energy Management Program (FEMP) provides acquisition guidance across a variety of product categories, including compact fluorescent lamps (CFLs), which are an ENERGY STAR-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR.

Note: This page contains sample records for the topic "lamp type standard" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Information Resources: LED Replacements for Linear Fluorescent Lamps  

NLE Websites -- All DOE Office Websites (Extended Search)

Replacements for Linear Fluorescent Lamps Webcast Replacements for Linear Fluorescent Lamps Webcast In this June 20, 2011 webcast on LED products marketed as replacements for linear fluorescent lamps, Jason Tuenge of the Pacific Northwest National Laboratory (PNNL) discussed current Lighting Facts-listed products as well as products evaluated in the latest CALiPER reports. Eric Richman, also of PNNL, reported on a recently completed GATEWAY demonstration project, in which LED and fluorescent lamps were installed in a variety of recessed troffer luminaires for comparison in an office environment. The presentation concluded with a discussion of specifications listed in a newly updated technology fact sheet. View presentation slides View the text-alternative version View the webcast (WMV 16 MB) Download Windows Media Player

122

Max Tech and Beyond: High-Intensity Discharge Lamps  

E-Print Network (OSTI)

the reason industry started by developing ceramic MH lampsceramic metal halide lamps, which are the focus of industryindustry had invested in the development of very low wattage ceramic

Scholand, Michael

2012-01-01T23:59:59.000Z

123

COST EFFECTIVENESS OF LONG LIFE INCANDESCENT LAMPS AND ENERGY BUTTONS  

E-Print Network (OSTI)

button, a 100 watt (130 volt) lamp, a 100 watt long lifeFluorescent Watt L I ltage (volts) cu ge ic in s) ative ( 1the diode energy button (83 volts) was obtained by dividing

Verderber, Rudy

2013-01-01T23:59:59.000Z

124

The LAMP QPF Products. Part I: Model Development  

Science Conference Proceedings (OSTI)

The Local AWIPS (Advanced Weather Interactive Processing System) MOS (model output statistics) Program (LAMP) quantitative precipitation forecast (QPF) system produces 122-h forecasts of precipitation over the conterminous United States. The ...

Jerome P. Charba

1998-12-01T23:59:59.000Z

125

Electronic Radio-Frequency (Electrodeless) Induction Lamps: A Fluorescent Technology  

Science Conference Proceedings (OSTI)

This EPRI Technical Update addresses an expanding energy efficient light source electronic radio-frequency (electrodeless) induction lamps. Business and technical market factors (Chapter 2) use the past and future growth of the CFL market to illustrate the potential for the induction lighting market while emphasizing future technical improvements. Discussion of the importance of utility involvement in helping their customers consider induction lamps for high-efficiency fluorescent applications with long-...

2007-12-20T23:59:59.000Z

126

An ultraviolet barrier-discharge OH molecular lamp  

Science Conference Proceedings (OSTI)

The energy and spectral parameters of a barrier discharge in a mixture of argon with hydroxyl {sup .}OH are studied experimentally. A sealed lamp with the radiation intensity maximum at {lambda} = 309.2 nm, an emitting surface area of {approx}700 cm{sup 2}, and a radiant excitance of 1.5 mW cm{sup -2} has been fabricated. The radiant power of the lamp is 1.1 W. (laser applications and other topics in quantum electronics)

Sosnin, E A; Erofeev, M V; Avdeev, S M; Panchenko, Aleksei N; Panarin, V A; Skakun, V S; Tarasenko, Viktor F; Shitts, D V [Institute of High Current Electronics, Siberian Branch, Russian Academy of Sciences, Tomsk (Russian Federation)

2006-10-31T23:59:59.000Z

127

Compact fluorescent lamp using horizontal and vertical insulating septums and convective venting geometry  

DOE Patents (OSTI)

A novel design is described for a compact fluorescent lamp, including a lamp geometry which will increase light output and efficacy of the lamp in a base down operating position by providing horizontal and vertical insulating septums positioned in the ballast compartment of the lamp to provide a cooler coldspot. Selective convective venting provides additional cooling of the ballast compartment. 9 figs.

Siminovitch, M.

1998-02-10T23:59:59.000Z

128

Compact fluorescent lamp using horizontal and vertical insulating septums and convective venting geometry  

SciTech Connect

A novel design for a compact fluorescent lamp, including a lamp geometry which will increase light output and efficacy of the lamp in a base down operating position by providing horizontal and vertical insulating septums positioned in the ballast compartment of the lamp to provide a cooler coldspot. Selective convective venting provides additional cooling of the ballast compartment.

Siminovitch, Michael (El Sobrante, CA)

1998-01-01T23:59:59.000Z

129

Standard model atmospheres for A-type stars and non-LTE effects  

E-Print Network (OSTI)

Abstract. The current status of NLTE model atmosphere calculations of A type stars is reviewed. During the last decade the research has concentrated on solving the restricted NLTE line formation problem for trace elements assuming LTE model atmospheres. There is a general lack of calculated NLTE line blanketed model atmospheres for A type stars, despite the availability of powerful methods and computer codes that are able to solve this task. Some directions for future model atmosphere research are suggested.

Daniela Kor?kov

2004-01-01T23:59:59.000Z

130

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Torchieres Torchieres Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of torchieres since 2005. A torchiere, or torch lamp, is a lamp fixture with a tall (such as 5 foot) stand of wood or metal. Torchiere lamps use fluorescent or halogen incandescent light bulbs. Recent Updates | Standards | Test Procedures | Waiver, Exception, and Exemption Information | Statutory Authority | Historical Information | Contact Information Recent Updates There are no recent updates for this product. Standards for Torchieres The following content summarizes the energy conservation standards of DOE's regulations. The text is not an official reproduction of the Code of Federal Regulations and should not be used for legal research or citation.

131

Very high efficacy electrodeless high intensity discharge lamps  

DOE Patents (OSTI)

An electrodeless arc lamp comprises an outer jacket hermetically sealing and thermally protecting an arc tube inside which has an upwardly convex bottom center section. The absence of chemically reactive electrode material makes it possible to use metal halides other than iodides. The tube contains chlorides, bromides or a mixture thereof of scandium and sodium in a nearly equimolar relationship in addition to mercury and an inert gas. Good color balance can be obtained at reduced reservoir temperature and with less power loss. Reduction in wall temperature makes it possible to attain longer lamp life.

Johnson, P.D.

1985-10-03T23:59:59.000Z

132

Buildings Energy Data Book: 7.6 Efficiency Standards for Lighting  

Buildings Energy Data Book (EERE)

2 2 Efficiency Standards for Incandescent Reflector Lamps (1) Effective for lamps manufactured after November 1, 1995 and before July 14, 2012 Minimum Nominal Average Lamp Lamp Wattage Efficacy (lm/W) 40-50 10.5 51-66 11.0 67-85 12.5 86-115 14.0 116-155 14.5 156-205 15.0 Effective for lamps manufactured on or after July 14, 2012 Minimum Rated Lamp Rated Average Lamp Lamp Wattage Lamp Spectrum Diameter (in) Voltage (V) Efficacy (lm/W) (2) 40-205 Standard Spectrum >2.5 ≥125 6.8*P^0.27 40-205 Standard Spectrum >2.5 <125 5.9*P^0.27 40-205 Standard Spectrum ≤2.5 ≥125 5.7*P^0.27 40-205 Standard Spectrum ≤2.5 <125 5.0*P^0.27 40-205 Modified Spectrum >2.5 ≥125 5.8*P^0.27 40-205 Modified Spectrum >2.5 <125 5.0*P^0.27 40-205 Modified Spectrum ≤2.5 ≥125 4.9*P^0.27

133

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Medium Base Compact Fluorescent Lamps Medium Base Compact Fluorescent Lamps Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of medium base compact fluorescent lamps since 2005. Medium base compact fluorescent lamps (CFLs) or bulbs are the often curly, screw-in versions of the long tube fluorescent lights commonly found in kitchens or garages. CFLs are available in a range of light colors, including incandescent-like "warm" tones. Some CFLs are encased in a bulb-shaped cover to further diffuse the light. These can be used with clamp-on lampshades. CFLs can provide the same lighting as traditional incandescent bulbs for reading and room lighting. The Energy Policy Act of 2005 (EPACT 2005) amended Energy Policy and Conservation Act of 1975 (EPCA) setting energy conservation standards for medium base compact fluorescent lamps. DOE will conduct an analysis of energy, emission and cost reductions when it reviews these standards in future rulemakings.

134

New LED light sources and lamps for general illumination  

E-Print Network (OSTI)

of light source compared to traditional light sources like incandescent bulbs and fluorescent tubes bulb. LEDs emit colored light with a narrow spectral band of 20-30 nm, colors covering the spectralNew LED light sources and lamps for general illumination Carsten Dam-Hansen, Birgitte Thestrup

135

Solid-State Lighting: LED Replacement Lamps: Current Performance and the  

NLE Websites -- All DOE Office Websites (Extended Search)

LED Replacement Lamps: Current LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® to someone by E-mail Share Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Facebook Tweet about Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Twitter Bookmark Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Google Bookmark Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Delicious Rank Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Digg Find More places to share Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on

136

Observed Minimum Illuminance Threshold for Night Market Vendors in Kenya who use LED Lamps  

E-Print Network (OSTI)

the economics of fuel-based and LED lighting technology fordata logger equipped rechargeable LED lamps, monitoring theadoption of the LED lamps, and a follow-up survey. 1 Figure

Johnstone, Peter

2009-01-01T23:59:59.000Z

137

Information on the Fate of Mercury From Fluorescent Lamps Disposed in Landfills  

Science Conference Proceedings (OSTI)

Mercury is contained in energy-efficient fluorescent, mercury-vapor, metal halide, and high-pressure sodium lamps. This report presents information on the potential for air and groundwater contamination when mercury lamps are disposed in municipal landfills.

1995-04-19T23:59:59.000Z

138

Mercury Lamps Recycling Fluorescent light-tubes, compact fluorescent bulbs, mercury and sodium vapor lamps, ultraviolet and  

E-Print Network (OSTI)

Mercury Lamps Recycling Fluorescent light-tubes, compact fluorescent bulbs, mercury and sodium light tubes are recycled. They are made from aluminum and metal. Aluminum is a silver-white metal and is very light in weight and strong. Because aluminum is ductile, it can be drawn into wires or pressed

Ungerleider, Leslie G.

139

Thermal element for maintaining minimum lamp wall temperature in fluorescent fixtures  

DOE Patents (OSTI)

In a lighting fixture including a lamp and a housing, an improvement is disclosed for maintaining a lamp envelope area at a cooler, reduced temperature relative to the enclosed housing ambient. The improvement comprises a thermal element in thermal communication with the housing extending to and springably urging thermal communication with a predetermined area of the lamp envelope surface.

Siminovitch, Michael J. (Richmond, CA)

1992-01-01T23:59:59.000Z

140

Thermal element for maintaining minimum lamp wall temperature in fluorescent fixtures  

DOE Patents (OSTI)

In a lighting fixture including a lamp and a housing, an improvement is disclosed for maintaining a lamp envelope area at a cooler, reduced temperature relative to the enclosed housing ambient. The improvement comprises a thermal element in thermal communication with the housing extending to and springably urging thermal communication with a predetermined area of the lamp envelope surface. 12 figs.

Siminovitch, M.J.

1992-11-10T23:59:59.000Z

Note: This page contains sample records for the topic "lamp type standard" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Criticality Analysis for Proposed Maximum Fuel Loading in a Standardized SNF Canister with Type 1a Baskets  

SciTech Connect

This document represents a summary version of the criticality analysis done to support loading SNF in a Type 1a basket/standard canister combination. Specifically, this engineering design file (EDF) captures the information pertinent to the intact condition of four fuel types with different fissile loads and their calculated reactivities. These fuels are then degraded into various configurations inside a canister without the presence of significant moderation. The important aspect of this study is the portrayal of the fuel degradation and its effect on the reactivity of a single canister given the supposition there will be continued moderation exclusion from the canister. Subsequent analyses also investigate the most reactive dry canister in a nine canister array inside a hypothetical transport cask, both dry and partial to complete flooding inside the transport cask. The analyses also includes a comparison of the most reactive configuration to other benchmarked fuels using a software package called TSUNAMI, which is part of the SCALE 5.0 suite of software.

Chad Pope; Larry L. Taylor; Soon Sam Kim

2007-02-01T23:59:59.000Z

142

Appliance Standard Program - The FY 2003 Priority -Setting Summary Report and Actions Proposed - Appendix B  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

APPENDIX B: APPENDIX B: Data Sheets for Existing Products Table of Contents Product Rulemaking Priority Page Product Rulemaking Priority Page Commercial Air-Cooled Central A/C & Air-Source HP, 65-240 kBtu/h Standards High B-1 High Intensity Discharge Lamps Determination High B-27 Central A/C & HP, 3 phase, < 65 kBtu/h Standards Medium B-2 Test Procedure Low B-28 Clothes Dryers Standards Low B-3 Lamps, Fluorescent Standards Low B-29 Test Procedure Low B-4 Test Procedure Low B-30 Clothes Washers Standards* Low B-5 Lamps, Incandescent General Service Standards Low B-31 Test Procedure* Low B-6 Test Procedure Low B-32 Commercial Water-Cooled A/C & Water- Source Heat Pumps Standards Low B-7 Lamps, Incandescent Reflector Standards Low B-33

143

Appliance Standard Program - The FY 2003 Priority -Setting Summary Report and Actions Proposed - Appendix B  

NLE Websites -- All DOE Office Websites (Extended Search)

APPENDIX B: APPENDIX B: Data Sheets for Existing Products Table of Contents Product Rulemaking Priority Page Product Rulemaking Priority Page Commercial Air-Cooled Central A/C & Air-Source HP, 65-240 kBtu/h Standards High B-1 High Intensity Discharge Lamps Determination High B-27 Central A/C & HP, 3 phase, < 65 kBtu/h Standards Medium B-2 Test Procedure Low B-28 Clothes Dryers Standards Low B-3 Lamps, Fluorescent Standards Low B-29 Test Procedure Low B-4 Test Procedure Low B-30 Clothes Washers Standards* Low B-5 Lamps, Incandescent General Service Standards Low B-31 Test Procedure* Low B-6 Test Procedure Low B-32 Commercial Water-Cooled A/C & Water- Source Heat Pumps Standards Low B-7 Lamps, Incandescent Reflector Standards Low B-33

144

Sulfur Lamps-The Next Generation of Efficient Light?  

NLE Websites -- All DOE Office Websites (Extended Search)

5 5 Sulfur Lamps-The Next Generation of Efficient Light? The figure above is a schematic of the system installed at the National Air and Space Museum and the DOE headquarters in Washington, D.C., Light from the sulfur lamp is focused by a parabolic reflector so that it enters the light pipe within a small angular cone. Light travels down the pipe, reflecting off the prismatic film (A) that lines the outer acrylic tube. The prismatic film reflects the light through total internal reflection (C), an intrinsically efficient process. Some of the light striking the film (at A) is not reflected and "leaks out" of the pipe walls (B), giving the pipe a glowing appearance. A light ray that travels all the way down the pipe will strike the mirror at the end (D) and return back up the pipe.

145

L Prize Competition Winner 60W Incandesent Replacement Lamp Update  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Technology Deployment Technology Deployment Working Group L Prize ® Competition Winner 60W Incandescent Replacement Lamp Update James E. Rannels, Senior Advisor L Prize Competition D&R International May 23, 2012 Philips Wins First L Prize 2 * August 3, 2011: Philips announced as winner of 60W replacement bulb category * Product distributed thru commercial and retail channels Image courtesy of Philips -...[O]nce an award is made the authorizing Act directs General Services Administration to develop federal purchasing schedules for solid-state lamps that meet or exceed the specifications laid out in the prize category-so long as it is cost effective. I hope the GSA begins this process soon.‖

146

Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps  

SciTech Connect

In support of the federal government's efforts to raise the minimum energy-efficiency standards for residential-type central air conditioners and heat pumps, a consumer life-cycle cost (LCC) analysis was conducted to demonstrate the economic impacts on individual consumers from revisions to the standards. LCC is the consumer's cost of purchasing and installing an air conditioner or heat pump and operating the unit over its lifetime. The LCC analysis is conducted on a nationally representative sample of air conditioner and heat pump consumers resulting in a distribution of LCC impacts showing the percentage of consumers that are either benefiting or being burdened by increased standards. Relative to the existing minimum efficiency standard of 10 SEER, the results show that a majority of split system air conditioner and heat pump consumers will either benefit or be insignificantly impacted by increased efficiency standards of up to 13 SEER.

Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

2001-10-10T23:59:59.000Z

147

Conservation potential of compact fluorescent lamps in India and Brazil  

SciTech Connect

We evaluate the conservation potential of compact fluorescent lamps (CFLs) for managing the rapidly increasing electrical energy and peak demand in India and Brazil. Using very conservative assumptions, we find that the cost of conserved energy using 16 W CFLs is 4 and 6 times less than the long range marginal cost of electricity for the two countries. The cost of avoided peak installed capacity is 6 and 9.5 times less than the cost of new installed capacity for India and Brazil. The analysis is undertaken from the three separate perspectives of the national economies, the consumers, and the utilities. We find that because residential electricity is subsidized, the consumers have little or no incentive to purchase and install the CFLs, unless they too are subsidized. However, the benefits of CFL installation to the utility are so large that subsidizing them is a paying proposition for the utility are so large that subsidizing them is a paying proposition for the utility in almost all cases. As an illustration of a gradual introduction strategy for CFLs, we calculate a scenario where national savings of the order of US $1.2 million per day for India and US $2.5 million per day for Brazil are reached in 10 years by a small and gradual transfer of subsidy from residential electricity to CFLs. We then explore the barriers to immediate large scale introduction of these lamps in the two countries. Specific technical and marketing problems are identified and discussed, which would require solution before such an introduction can be attempted. Lastly, we discuss the range of policy instruments, in addition to a subsidy scheme, that can be used for promoting the diffusion of these lamps in the domestic and commercial sector. 47 refs., 15 figs., 2 tabs.

Gadgil, A.; Martino Jannuzzi, G. de (Lawrence Berkeley Lab., CA (USA); Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia)

1989-07-01T23:59:59.000Z

148

Energy efficiency lighting on board naval ships: Phase 2 (The T-8 lamp system)  

SciTech Connect

This report describes the development and performance of the T-8 fluorescent lamp-ballast system. Similar to the Phase I effort, the cooperation of the lamp and ballast companies (GTE, North American Philips Lighting, and IOTA Engineering) were required for the successful result. The above companies submitted prototype lamps and ballasts to the Lawrence Berkeley Laboratory Lighting Group to evaluate. The lamp designs were modified as required and the optimum system selected. Two-lamp designs and one ballast were chosen and tested to determine if they met the Navy specifications. The second section describes the lamp-ballast specifications. This section includes the measured thermal performance from an ambient of 10/degree/C to 60/degree/C. 1 ref., 8 figs., 11 tabs.

Verderber, R.R.

1987-01-31T23:59:59.000Z

149

Microwave lamp with multi-purpose rotary motor  

DOE Patents (OSTI)

In a microwave powered electrodeless lamp, a single rotary motor is used to (a) rotate the bulb and (b) provide rotary motion to a blower or pump means for providing cooling fluid to the magnetron and/or to a forced gas cooler for providing cooling gas to the bulb. The blower may consist of only of an impeller without the usual blower housing. The motor, bulb stem and bulb, or motor, bulb stem, bulb and blower may be formed as an integral unit so as to facilitate replacement. 8 figs.

Ury, M.G.; Turner, B.; Wooten, R.D.

1999-02-02T23:59:59.000Z

150

Microwave lamp with multi-purpose rotary motor  

DOE Patents (OSTI)

In a microwave powered electrodeless lamp, a single rotary motor is used to a) rotate the bulb and b) provide rotary motion to a blower or pump means for providing cooling fluid to the magnetron and/or to a forced gas cooling for providing cooler gas to the bulb. The blower may consist of only of an impeller without the usual blower housing. The motor, bulb stem and bulb, or motor, bulb stem, bulb and blower may be formed as an integral unit so as to facilitate replacement.

Ury, Michael G. (Bethesda, MD); Turner, Brian (Myersville, MD); Wooten, Robert D. (Rockville, MD)

1999-01-01T23:59:59.000Z

151

Low pressure arc discharge lamp apparatus with magnetic field generating means  

DOE Patents (OSTI)

A low-pressure arc discharge apparatus having a magnetic field generating means for increasing the output of a discharge lamp is disclosed. The magnetic field generating means, which in one embodiment includes a plurality of permanent magnets, is disposed along the lamp for applying a constant transverse magnetic field over at least a portion of the positive discharge column produced in the arc discharge lamp operating at an ambient temperature greater than about 25 C. 3 figs.

Grossman, M.W.; George, W.A.; Maya, J.

1987-10-06T23:59:59.000Z

152

The construction industry is comprised of a wide range of businesses involved in engineering standards, building design, and the construction of various types of materials and  

E-Print Network (OSTI)

thermal characteristics of buildings for insulation purposes, and to determine heating, cooling in engineering standards, building design, and the construction of various types of materials and structures-related impacts, such as high winds and flooding, influence the choice of site construction, building techniques

153

Observed Minimum Illuminance Threshold for Night Market Vendors in Kenya who use LED Lamps  

E-Print Network (OSTI)

for Small Businesses in Kenya." Lumina Project Technicalfor Night Market Vendors in Kenya who use LED Lamps Petermany people and businesses in Kenya who participated in this

Johnstone, Peter

2009-01-01T23:59:59.000Z

154

Demonstration of LED Retrofit Lamps at the Smithsonian American Art Museum, Washington, DC  

Science Conference Proceedings (OSTI)

This report documents observations and results obtained from a lighting demonstration project conducted under the U.S. Department of Energy GATEWAY Solid-State Lighting (SSL) Technology Demonstration Program at the Smithsonain American Art Museum in Washington, DC. LED Lamp samples were tested in the museum workshop, temporarily installed in a gallery for feedback, and ultimately replaced all traditional incandescent lamps in one gallery of modernist art at the American Art Museum and partially replacing lamps in two galleries at the Musesum's Renwick Gallery. This report describes the selection and testing process, technology challenges, perceptions, economics, energy use, and mixed results of usign LED replacement lamps in art galleries housing national treasures.

Miller, Naomi J.; Rosenfeld, Scott M.

2012-06-22T23:59:59.000Z

155

Dimming of Compact Fluorescent Lamps Caused By Cold-Air Drafts  

Science Conference Proceedings (OSTI)

This Case Study documents the investigation performed by the New York Port Authority (PA) of the dimming of compact fluorescent lamps (CFLs) in the World Trade Center.

2003-12-31T23:59:59.000Z

156

Power control architectures for cold cathode fluorescent lamp and light emitting diode based light sources.  

E-Print Network (OSTI)

?? In this dissertation, two different energy efficient power supply topologies are introduced for controlling cold cathode fluorescent lamp (CCFL) and high-brightness light emitting diode (more)

Doshi, Montu V.

2010-01-01T23:59:59.000Z

157

A new optimized fluorescent lamp and ballast for low-energy general lighting applications  

SciTech Connect

A new fluorescent lamp and ballast system has been developed which minimizes system input power while maintaining light output close to values provided by conventional lamps and ballasts. The 28-WT-12 lamp designed for the new system utilizes a redesigned electrode structure which allows the lamp to be started in the rapid start manner but operated in an instant start mode to maximize the discharge efficacy (lumens/watt) while reducing lamp cathode power requirements. A matching two-lamp ballast incorporates a solid-state switching device to turn off the cathode heating circuit automatically once the lamps have started. Both lamps and ballasts are physically interchangeable with conventional equipment so that existing luminaires can be converted without luminaire, lampholder, and wiring modifications. This new lamp/ballast system can achieve efficacy values exceeding 80 lm/W--more than 25 percent better than the performance of conventional fluorescent systems of the early 1970's-along with the excellent life and reliability characteristics typical of electromagnetically ballasted systems. Economic analyses indicate that the new system is appropriate for many new commercial general lighting installations, although it is particularly suitable as a retrofit system for installations where power reductions are essential but where conversion costs must be minimized and illumination levels preserved.

Hammer, E.E.; McGowan, T.K.

1983-07-01T23:59:59.000Z

158

Types of Lighting in Commercial Buildings - Changes  

U.S. Energy Information Administration (EIA) Indexed Site

Changes in Lighting Changes in Lighting The percentage of commercial buildings with lighting was unchanged between 1995 and 2003; however, three lighting types did show change in usage. Compact fluorescent lamps and halogen lamps showed a significant increase between 1995 and 2003 while the use of incandescent lights declined. The lighting questions in the 1995, 1999, and 2003 CBECS questionnaires were virtually identical which facilitates comparison across survey years. The use of compact fluorescent lamps more than doubled, from just under 10 percent of lit buildings to more than 20 percent (Figure 17 and Table 5). The use of halogen lamps nearly doubled, from 7 percent to 13 percent of lit buildings. Use of incandescent lights was the only lighting type to decline; their use dropped from 59 percent to just over one-half of lit buildings.

159

Research on Active Power Factor Correction of the Electronic Ballast for High-Pressure Sodium Lamps Based on L6563  

Science Conference Proceedings (OSTI)

In the recent years, there has been a growing interest in the design of high-pressure sodium lamp electronic ballast. Two measures are proposed to improve the power factor of high-pressure sodium lamp electronic ballasts from the definition of harmonic ... Keywords: high-pressure sodium lamps, electronic ballast, active power factor correction, L6563

Sun Jing

2010-06-01T23:59:59.000Z

160

A light diet for a giant appetite: An assessment of China's proposed fluorescent lamp standard  

E-Print Network (OSTI)

Green Lights Program to promote efficient lighting products through public education, consumer incentives, national product testing, and investments

Lin, Jiang

2002-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "lamp type standard" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Calibration Procedures: Standard Operating Procedures  

Science Conference Proceedings (OSTI)

... 18, Calibration of Graduated Neck-Type Metal Volumetric Field Standards, Volumetric Transfer Method Revision ... 20, Standard Deviation and Range ...

2013-09-03T23:59:59.000Z

162

NIST Global Standards Information Europe  

Science Conference Proceedings (OSTI)

... and electronic household and office equipment; set-top-boxes; electric motors; wet-rotor pumps; directional lamps, light emitting diode lamps and ...

163

NIST Global Standards Information Switzerland  

Science Conference Proceedings (OSTI)

... and electronic household and office equipment; set-top-boxes; electric motors; wet-rotor pumps; directional lamps, light emitting diode lamps and ...

164

Lamp system with conditioned water coolant and diffuse reflector of polytetrafluorethylene(PTFE)  

SciTech Connect

A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.

Zapata, Luis E. (Livermore, CA); Hackel, Lloyd (Livermore, CA)

1999-01-01T23:59:59.000Z

165

Lamp system with conditioned water coolant and diffuse reflector of polytetrafluorethylene(PTFE)  

SciTech Connect

A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO{sub 2}) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.

Zapata, L.E.; Hackel, L.

1999-10-26T23:59:59.000Z

166

Identification of lamp ballasts containing PCBs. Revised edition. Report no. EPS 2/CC/2  

SciTech Connect

Fluorescent lamp ballast capacitors are among the products that may contain polychlorinated biphenyls (PCBs). Questions about lamp ballasts concern the potential for leakage, the risk of heating and exploding, how to identify a ballast which contains PCBs, and the risk to human health. This study identifies those ballasts containing PCB-filled capacitors; the domestic and foreign manufacturers of PCB-containing ballasts; the total quantity of PCBs used in ballasts; and any potential problems. The study does not identify the risks of human health arising from the use of PCB-ballasts in fluorescent lamps.

1991-01-01T23:59:59.000Z

167

Types of Lighting in Commercial Buildings - Lighting Characteristics  

U.S. Energy Information Administration (EIA) Indexed Site

Characteristics of Lighting Types Characteristics of Lighting Types Efficacy Efficacy is the amount of light produced per unit of energy consumed, expressed in lumens per watt (lm/W). Lamps with a higher efficacy value are more energy efficient. Average Rated Life The average rated life of a particular type of lamp is defined by the number of hours when 50 percent of a large sample of that type of lamp has failed. Color Rendering Index (CRI) The CRI is a measurement of a light source's accuracy in rendering different colors when compared to a reference light source. The highest attainable CRI is 100. Lamps with CRIs above 70 are typically used in office and living environments. Correlated Color Temperature (CCT) The CCT is an indicator of the "warmth" or "coolness" of the color

168

Miniature UV lamp excited by subnanosecond voltage pulses  

SciTech Connect

Energy, time, and spectral characteristics of emission of the second positive system of N{sub 2} molecules in gaseous nitrogen, Ar - N{sub 2} mixture, and air are investigated. An FPG-10 generator with voltage pulse FWHM of 200 and 400 ps and matched-load amplitudes of 14 and 6 kV, respectively, is used to excite gases. It is shown that excitation can be performed in two regimes using this generator. In the first regime a diffuse discharge is formed at atmospheric pressure, which opens ways to design miniature nanosecond UV lamps. A diffuse discharge is formed due to the generation of runaway electrons, with the aid of electrodes having a small radius of curvature and voltage pulses with a sharp leading edge. In the second regime an elevated average radiation power is obtained under excitation by a barrier discharge. However, the operating pressure is lower in this case, and the sizes of the emitting region and the UV pulse width significantly increase. (laser applications and other topics in quantum electronics)

Erofeev, M V; Baksht, E Kh; Tarasenko, Viktor F; Shut'ko, Yu V [Institute of High Current Electronics, Siberian Branch, Russian Academy of Sciences, Tomsk (Russian Federation)

2010-08-27T23:59:59.000Z

169

Integrated starting and running amalgam assembly for an electrodeless fluorescent lamp  

DOE Patents (OSTI)

An integrated starting and running amalgam assembly for an electrodeless SEF fluorescent lamp includes a wire mesh amalgam support constructed to jointly optimize positions of a starting amalgam and a running amalgam in the lamp, thereby optimizing mercury vapor pressure in the lamp during both starting and steady-state operation in order to rapidly achieve and maintain high light output. The wire mesh amalgam support is constructed to support the starting amalgam toward one end thereof and the running amalgam toward the other end thereof, and the wire mesh is rolled for friction-fitting within the exhaust tube of the lamp. The positions of the starting and running amalgams on the wire mesh are jointly optimized such that high light output is achieved quickly and maintained, while avoiding any significant reduction in light output between starting and running operation.

Borowiec, Joseph Christopher (Schenectady, NY); Cocoma, John Paul (Clifton Park, NY); Roberts, Victor David (Burnt Hills, NY)

1998-01-01T23:59:59.000Z

170

On the Brightness of the Thomson Lamp: A Prolegomenon to Quantum Recursion Theory  

Science Conference Proceedings (OSTI)

Some physical aspects related to the limit operations of the Thomson lamp are discussed. Regardless of the formally unbounded and even infinite number of "steps" involved, the physical limit has an operational meaning in agreement with the Abel sums ...

Karl Svozil

2009-09-01T23:59:59.000Z

171

Candelabra and Intermediate Base Lamps Enforcement Policy Statement  

Energy.gov (U.S. Department of Energy (DOE))

The Department issued guidance today advising manufacturers, importers and private labelers that DOE will not enforce the energy conservation standards and compliance certification requirements for...

172

Microsoft Word - Guidance Concerning Enforcement of EISA 2007 Standards for.docx  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Enforcement of EISA 2007 Standards for Enforcement of EISA 2007 Standards for Candelabra Base and Intermediate Base Lamps Issued: July 1, 2011 The Energy Independence and Security Act of 2007 (EISA 2007) imposed energy conservation standards for candelabra and intermediate base lamps, and those provisions became effective with the statute. Despite the language of the statute, DOE has been made aware that for the last several years there has been an understanding among interested stakeholders that the standards would not become effective until January 1, 2012. That understanding was solidified by DOE staff statements suggesting that energy conservation standards for candelabra and intermediate base lamps would not be enforced until then. DOE understands that manufacturers made production

173

X-ray Methods in High-Intensity Discharges and Metal-Halide Lamps: X-ray Induced Fluorescence  

SciTech Connect

We describe the use of x-ray induced fluorescence to study metal-halide high-intensity discharge lamps and to measure equilibrium vapor pressures of metal-halide salts. The physical principles of metal-halide lamps, relevant aspects of x-ray-atom interactions, the experimental method using synchrotron radiation, and x-ray induced fluorescence measurements relevant to metal-halide lamps are covered.

Curry, John J.; Lapatovich, Walter P.; Henins, Albert (NIST)

2011-12-09T23:59:59.000Z

174

Appliance Standard Program - The FY 2003 Priority -Setting Summary...  

NLE Websites -- All DOE Office Websites (Extended Search)

Fluorescent Lamp Ballasts Electric Motors, 1-200HP Fluorescent Lamps Commercial Oil- and Gas-Fired Packaged Boilers Mobile Home Furnaces High-Intensity Discharge Lamps...

175

Determination of the cathode and anode voltage drops in high power low-pressure amalgam lamps  

Science Conference Proceedings (OSTI)

For the first time, cathode and anode drops of powerful low-pressure amalgam lamps were measured. The lamp discharge current is 3.2 A, discharge current frequency is 43 kHz, linear electric power is 2.4 W/cm. The method of determination of a cathode drop is based on the change of a lamp operating voltage at variation of the electrode filament current at constant discharge current. The total (cathode plus anode) drop of voltage was measured by other, independent ways. The maximum cathode fall is 10.8 V; the anode fall corresponding to the maximal cathode fall is 2.4 V. It is shown that in powerful low pressure amalgam lamps the anode fall makes a considerable contribution (in certain cases, the basic one) to heating of electrodes. Therefore, the anode fall cannot be neglected, at design an electrode and ballast of amalgam lamps with operating discharge current frequency of tens of kHz.

Vasilyak, L. M., E-mail: vasilyak@ihed.ras.ru [Russian Academy of Sciences, Joint Institute for High Temperatures (Russian Federation); Vasiliev, A. I., E-mail: vasiliev@npo.lit.ru; Kostyuchenko, S. V.; Sokolov, D. V.; Startsev, A. Yu. [Joint Stock Company NPO LIT (Russian Federation); Kudryavtsev, N. N. [Moscow Institute of Physics and Technology (State University) (Russian Federation)

2011-12-15T23:59:59.000Z

176

COST EFFECTIVENESS OF LONG LIFE INCANDESCENT LAMPS AND ENERGY BUTTONS  

E-Print Network (OSTI)

placed into light bulb sockets (Edison sockets) and the lampbe inserted into the same Edison type socket that is usedto injury. In addition, Edison sockets that are hori~

Verderber, Rudy

2013-01-01T23:59:59.000Z

177

L-Prize Competition Winner 60W Incandescent Replacement Lamp Update  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interagency Technology Deployment Working Group L Prize ® Competition Winner 60W Incandescent Replacement Lamp Update James E. Rannels, Senior Advisor L Prize Competition D&R International March 15, 2012 Cost of electricity 1 cent per kilowatt-hour The Washington Post, March 8, 2012 Page One 2 Cost of electricity 11 cents per kilowatt-hour The Washington Post, March 9, 2012 Page Two 3 What Is the L Prize? * Technology competition to spur innovation and exceptional performance * Created by Energy Independence and Security Act (EISA 2007) Sec. 655 * Two key lamp replacements: 60W Incandescent and PAR 38 Halogen * Future focus: 21 st Century Lamp * Cash prizes, federal purchasing, utility programs 4 Philips Wins First L Prize * August 3, 2011: Philips

178

L-Prize Competition Winner 60W Incandescent Replacement Lamp Update  

NLE Websites -- All DOE Office Websites (Extended Search)

Interagency Technology Deployment Working Group L Prize ® Competition Winner 60W Incandescent Replacement Lamp Update James E. Rannels, Senior Advisor L Prize Competition D&R International March 15, 2012 Cost of electricity 1 cent per kilowatt-hour The Washington Post, March 8, 2012 Page One 2 Cost of electricity 11 cents per kilowatt-hour The Washington Post, March 9, 2012 Page Two 3 What Is the L Prize? * Technology competition to spur innovation and exceptional performance * Created by Energy Independence and Security Act (EISA 2007) Sec. 655 * Two key lamp replacements: 60W Incandescent and PAR 38 Halogen * Future focus: 21 st Century Lamp * Cash prizes, federal purchasing, utility programs 4 Philips Wins First L Prize * August 3, 2011: Philips

179

Selecting effective fluorescent lamp and ballast for retrofit in the continental United States. Final report  

SciTech Connect

Electrical lighting is a major contributor to daytime peak energy demand, accounting for about 30 percent of total electricity consumption in most Army facilities. Some of this energy may be wasted because many existing lighting systems at Army Installations use outmoded technologies. While recent technology has improved the energy efficiency of all lighting systems, fluorescent lighting-the most widely used interior building lighting-has shown the greatest efficiency gains. Retrofits using high-efficiency fluorescent lamps and ballasts can yield significant operating cost savings. High-efficiency fluorescent lighting systems are widely available, but current information on their performance characteristics is highly technical and not easily accessible to Army facility managers considering retrofit options. This report provides a single, accessible source that summarizes fluorescent lamp and ballast performance characteristics and outlines selection procedures. Fluorescent lamp, Retrofit, Ballast, Lighting. Energy conservation.

Taylor, W.R.

1993-08-01T23:59:59.000Z

180

Nature of the effect of the ballast volumes of flash lamps on their emission  

SciTech Connect

The cause of the decrease in laser efficiency during pumping by flash lamps with increased ballast volumes is the unproductive loss of radiation, originating from the ballast volumes, and the associated change in the radiation brightness distribution along the length of the lamp. The increase radiation brightness at the electrodes of the light source is not the result of constriction of the discharge or the luminescence of the electrode plasma erosion, but is due to the slowing down of the plasma flows by the surface of the electrodes and to the slowing down of the ionized gas moving from the ballast volumes when it meets the denser plasma of the discharge zone. The profile of the current lines at the electrodes is established and the frequency of the axial oscillations of the plasma in the lamp is determined.

Basov, Yu.G.; Makarov, V.N.; Narkhova, G.I.

1975-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "lamp type standard" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Compact light source performance in recessed type luminaires  

SciTech Connect

Photometric comparisons were made with an indoor, recessed, type luminaire using incandescent, high intensity discharge and compact fluorescent lamps. The test results show substantial performance advantages, as expected, for the discharge light sources where the efficacy gains can be in the order for 400% even when including the ballast losses associated with the discharge lamps. The candlepower distribution patterns emerging from these luminaries are also different from those associated with the baseline incandescent lamps, and which are in some ways, even more desirable from a uniformity of illuminance perspective. A section on fluorescent lamp starting is also included which describes a system having excellent starting characteristics in terms of electrode starting temperature (RH/RC technique), proper operating frequency to minimize unwanted IR interactions, and satisfactory current crest factor values to help insure life performance.

Hammer, E.E.

1998-11-01T23:59:59.000Z

182

Potential Environmental Impacts from the Metals in Incandescent, Compact Fluorescent Lamp (CFL), and Light-Emitting Diode (LED)  

E-Print Network (OSTI)

), and Light-Emitting Diode (LED) Bulbs Seong-Rin Lim, Daniel Kang, Oladele A. Ogunseitan,,§ and Julie M sources with compact fluorescent lamp (CFL) and light-emitting diode (LED) bulbs that use about 70% and 85 lighting systems are transitioning from incandes- cent to compact fluorescent lamp (CFL) and light

Short, Daniel

183

NIST Standardization support  

Science Conference Proceedings (OSTI)

... detail the color specifications of LED lamps and LED light fixtures; test methods for measuring total light output, energy efficiency, and color quality ...

2012-10-02T23:59:59.000Z

184

High frequency transformerless electronics ballast using double inductor-capacitor resonant power conversion for gas discharge lamps  

SciTech Connect

A novel high frequency LCLC double resonant electronic ballast has been developed for gas discharge lamp applications. The ballast consists of a half-bridge inverter which switches at zero voltage crossing and an LCLC resonant circuit which converts a low ac voltage to a high ac voltage. The LCLC resonant circuit has two LC stages. The first LC stage produces a high voltage before the lamp is ignited. The second LC stage limits lamp current with the circuit inductance after the lamp is ignited. In another embodiment a filament power supply is provided for soft start up and for dimming the lamp. The filament power supply is a secondary of the second resonant inductor. 27 figs.

Lai, J.S.

1995-06-20T23:59:59.000Z

185

15 KJ FLASH LAMP, POWER CONDITIONING UNIT DESIGNED FOR SAFTY, RELIABILITY & MANUFACTURABILITY*  

SciTech Connect

A 15kJoule, Flash Lamp Power Conditioning Unit has been successfully designed, developed, and deployed in the National Ignition Facility (NIF) Preamplifier Modules (PAM). The primary design philosophy of this power conditioning unit (PCU) is safety, reliability, and manufacturability. Cost reduction over commercially equivalent systems was also achieved through an easily manufactured packaging design optimized to meet NIF requirements. While still maintaining low cost, the PCU design includes a robust control system, fault diagnostic system, and safety features. The pulsed power design includes 6 PFN modules, each including a dual series injection trigger transformer, that drive a total of 12 flash lamp loads. The lamps are individually triggered via a 20kV pulse produced by a 1kV, MCT switched capacitive discharge unit on the primary side of the trigger transformer. The remote control interface includes an embedded controller that captures flash lamp current wave forms and fault status for each shot. The embedded controller provides the flexibility of remotely adjusting both the main drive voltage from 1.6 to 2.5 kV and the trigger voltage from 0 to 20 kV.

James, G; Merritt, B; Dreifuerst, G; Strickland, S

2007-08-07T23:59:59.000Z

186

Method and apparatus for powering an electrodeless lamp with reduced radio frequency interference  

DOE Patents (OSTI)

An electrodeless lamp waveguide structure includes tuned absorbers for spurious RF signals. A lamp waveguide with an integral frequency selective attenuation includes resonant absorbers positioned within the waveguide to absorb spurious out-of-band RF energy. The absorbers have a negligible effect on energy at the selected frequency used to excite plasma in the lamp. In a first embodiment, one or more thin slabs of lossy magnetic material are affixed to the sidewalls of the waveguide at approximately one quarter wavelength of the spurious signal from an end wall of the waveguide. The positioning of the lossy material optimizes absorption of power from the spurious signal. In a second embodiment, one or more thin slabs of lossy magnetic material are used in conjunction with band rejection waveguide filter elements. In a third embodiment, one or more microstrip filter elements are tuned to the frequency of the spurious signal and positioned within the waveguide to couple and absorb the spurious signal's energy. All three embodiments absorb negligible energy at the selected frequency and so do not significantly diminish the energy efficiency of the lamp.

Simpson, James E. (Gaithersburg, MD)

1999-01-01T23:59:59.000Z

187

RF driven sulfur lamp having driving electrodes which face each other  

DOE Patents (OSTI)

A high intensity discharge lamp without mercury is disclosed radiating a selected spectrum of which can be almost entirely in the visible range from an envelope that contains a sulfur containing substance. The lamp utilizes a signal source that generates an excitation signal that is externally coupled to the exterior surface of the envelope to excite the enclosed sulfur containing substance. Various embodiments of the lamp use electrodes adjacent the envelope to couple the excitation signal thereto with the face of the electrodes shaped to complement the shape of the exterior surface of the envelope. Two shapes discussed are spherical and cylindrical. To minimize filamentary discharges each envelope may include an elongated stem affixed to the exterior thereof whereby a rotational subsystem spins the envelope. In yet another embodiment the envelope has a Dewar configuration with two electrodes, one positioned near the external curved side surface of the body, and a second to the inner surface of the hole through the envelope. Further, the envelope may contain a backfill of a selected inert gas to assist in the excitation of lamp with that backfill at a pressure of less than 1 atmosphere, wherein the backfill pressure is directly related to the increase or decrease of peak output and inversely related to the increase and decrease of the emitted spectrum from the envelope. The emitting fill can be less than 6 mg/cc, or at least 2 mg/cc of the envelope of a sulfur containing substance. 17 figs.

Gabor, G.; Orr, T.R.; Greene, C.M.; Crawford, D.G.; Berman, S.M.

1999-06-22T23:59:59.000Z

188

Method and apparatus for powering an electrodeless lamp with reduced radio frequency interference  

DOE Patents (OSTI)

An electrodeless lamp waveguide structure includes tuned absorbers for spurious RF signals. A lamp waveguide with an integral frequency selective attenuation includes resonant absorbers positioned within the waveguide to absorb spurious out-of-band RF energy. The absorbers have a negligible effect on energy at the selected frequency used to excite plasma in the lamp. In a first embodiment, one or more thin slabs of lossy magnetic material are affixed to the sidewalls of the waveguide at approximately one quarter wavelength of the spurious signal from an end wall of the waveguide. The positioning of the lossy material optimizes absorption of power from the spurious signal. In a second embodiment, one or more thin slabs of lossy magnetic material are used in conjunction with band rejection waveguide filter elements. In a third embodiment, one or more microstrip filter elements are tuned to the frequency of the spurious signal and positioned within the waveguide to couple and absorb the spurious signal's energy. All three embodiments absorb negligible energy at the selected frequency and so do not significantly diminish the energy efficiency of the lamp. 18 figs.

Simpson, J.E.

1999-06-08T23:59:59.000Z

189

Issues, Models and Solutions for Triac Modulated Phase Dimming of LED Lamps  

E-Print Network (OSTI)

/a 30 lumens 0.1 Incandescent Bulb 15 W 225 lumens 15 Fluorescent Tube Lamp 10 W 500 lumens 50 White LED bulbs, and fluorescent lights, produce light that is radiated in all directions, LEDs produce a focused especially on the potential of white LED lights, which are an important and newly emerging lighting

Lehman, Brad

190

A Local AFOS MOS Program (LAMP) and its Application to Wind Prediction  

Science Conference Proceedings (OSTI)

The Techniques Development Laboratory has a project called the local AFOS MOS Program (LAMP). Its purpose is the development of a system which can produce at any hour of the day in a Weather Service Forecast Office (WSFO) environment Model Output ...

Harry R. Glahn; David A. Unger

1986-07-01T23:59:59.000Z

191

The Fuzzy Design of the Intelligent System for the Energy-Saving Lamps  

Science Conference Proceedings (OSTI)

In the paper, a intelligent system was proposed. It consists of variable converter and intelligent controller. Variable reactor which concludes variable reactance converter and power converter has wide applications in the soft starting, speed controlling ... Keywords: fuzzy control, variable reactor, intelligent control, power converter, Energy-Saving Lamps

Youxin Yuan; Kaihua Cui; Yiping Xiao; Tieliang Xu

2008-12-01T23:59:59.000Z

192

Energy Performance and Emissions of Electronic Ballasts Powering 4-Foot Fluorescent Lamps  

Science Conference Proceedings (OSTI)

This power quality (PQ) case study presents tests performed at the Worcester Polytechnic Institute, in contract with the EPRI Power Electronics Applications Center (PEAC) to determine the average efficacy (lumens per watt), displacement power factor, total power factor, and current harmonic distortion of modern electronic ballasts powering fluorescent lamps.

2003-12-31T23:59:59.000Z

193

Electronic screw-in ballast and improved circline lamp phase I. Final report  

SciTech Connect

A solid state ballast has been designed for the efficient operation of a 10 in circline fluorescent lamp. The circuit can be manufactured using power hybrid technology. Eight discrete component versions of the ballasts have been delivered to LBL for testing. The results show the solid state fluorescent ballast system is more efficient than the core-coil ballasted systems on the market.

Kohler, T.P.

1980-09-01T23:59:59.000Z

194

A Comparative Verification of Localized Aviation Model Output Statistics Program (LAMP) and Numerical Weather Prediction (NWP) Model Forecasts of Ceiling Height and Visibility  

Science Conference Proceedings (OSTI)

In an effort to support aviation forecasting, the National Weather Services Meteorological Development Laboratory (MDL) has recently redeveloped the Localized Aviation Model Output Statistics (MOS) Program (LAMP) system. LAMP is designed to run ...

David E. Rudack; Judy E. Ghirardelli

2010-08-01T23:59:59.000Z

195

Stress Testing of the Philips 60W Replacement Lamp L Prize Entry  

SciTech Connect

The Pacific Northwest National Laboratory, operated by Battelle for the U.S. Department of Energy, worked with Intertek to develop a procedure for stress testing medium screw-base light sources. This procedure, composed of alternating stress cycles and performance evaluation, was used to qualitatively compare and contrast the durability and reliability of the Philips 60W replacement lamp L Prize entry with market-proven compact fluorescent lamps (CFLs) with comparable light output and functionality. The stress cycles applied simultaneous combinations of electrical, thermal, vibration, and humidity stresses of increasing magnitude. Performance evaluations measured relative illuminance, x chromaticity and y chromaticity shifts after each stress cycle. The Philips L Prize entry lamps appear to be appreciably more durable than the incumbent energy-efficient technology, as represented by the evaluated CFLs, and with respect to the applied stresses. Through the course of testing, all 15 CFL samples permanently ceased to function as a result of the applied stresses, while only 1 Philips L Prize entry lamp exhibited a failure, the nature of which was minor, non-destructive, and a consequence of a known (and resolved) subcontractor issue. Given that current CFL technology appears to be moderately mature and no Philips L Prize entry failures could be produced within the stress envelope causing 100 percent failure of the benchmark CFLs, it seems that, in this particular implementation, light-emitting diode (LED) technology would be much more durable in the field than current CFL technology. However, the Philips L Prize entry lamps used for testing were carefully designed and built for the competition, while the benchmark CFLs were mass produced for retail salea distinction that should be taken into consideration. Further reliability testing on final production samples would be necessary to judge the extent to which the results of this analysis apply to production versions of the Philips L Prize entry.

Poplawski, Michael E.; Ledbetter, Marc R.; Smith, Mark

2012-04-24T23:59:59.000Z

196

Zero energy-storage ballast for compact fluorescent lamps  

DOE Patents (OSTI)

A CFL ballast includes complementary-type switching devices connected in series with their gates connected together at a control node. The switching devices supply a resonant tank circuit which is tuned to a frequency near, but slightly lower than, the resonant frequency of a resonant control circuit. As a result, the tank circuit restarts oscillations immediately following each zero crossing of the bus voltage. Such rapid restarts avoid undesirable flickering while maintaining the operational advantages and high efficacy of the CFL ballast.

Schultz, William Newell (Niskayuna, NY); Thomas, Robert James (Rexford, NY)

1999-01-01T23:59:59.000Z

197

Appliance Energy Efficiency Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Appliance Energy Efficiency Standards Appliance Energy Efficiency Standards Program Information Maryland Program Type ApplianceEquipment Efficiency Standards '' Note: The federal...

198

Appliance and Equipment Energy Efficiency Standards | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

and Equipment Energy Efficiency Standards Appliance and Equipment Energy Efficiency Standards Program Information New York Program Type ApplianceEquipment Efficiency Standards ''...

199

Zero energy-storage ballast for compact fluorescent lamps  

DOE Patents (OSTI)

A CFL ballast includes complementary-type switching devices connected in series with their gates connected together at a control node. The switching devices supply a resonant tank circuit which is tuned to a frequency near, but slightly lower than, the resonant frequency of a resonant control circuit. As a result, the tank circuit restarts oscillations immediately following each zero crossing of the bus voltage. Such rapid restarts avoid undesirable flickering while maintaining the operational advantages and high efficacy of the CFL ballast. 4 figs.

Schultz, W.N.; Thomas, R.J.

1999-08-31T23:59:59.000Z

200

NOPM and Availability of Framework Document for HID Lamps  

NLE Websites -- All DOE Office Websites (Extended Search)

8:48 Feb 27, 2012 8:48 Feb 27, 2012 Jkt 226001 PO 00000 Frm 00008 Fmt 4702 Sfmt 4702 E:\FR\FM\28FEP1.SGM 28FEP1 mstockstill on DSK4VPTVN1PROD with PROPOSALS Federal Register / Vol. 77, No. 39 / Tuesday, February 28, 2012 / Proposed Rules 11785 collections for particular program, except where required by statute. III. Questions for Comment The list below includes the questions about these reform ideas that address issues which are of greatest interest to OMB at this stage of the process. Comments addressing any other concerns, and other types of feedback, are also welcome. In addition, as was explained at the beginning of this notice, the public comments received by OMB will be posted on OMB's Web site and at http:// www.regulations.gov. Accordingly, please do not include in your comments

Note: This page contains sample records for the topic "lamp type standard" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Treatability study for removal of leachable mercury in crushed fluorescent lamps  

SciTech Connect

Nonserviceable fluorescent lamps removed from radiological control areas at the Oak Ridge Department of Energy facilities have been crushed and are currently managed as mixed waste (hazardous and radiologically contaminated). We present proposed treatment flowsheets and supporting treatability study data for conditioning this solid waste residue so that it can qualify for disposal in a sanitary landfill. Mercury in spent fluorescent lamps occurs primarily as condensate on high-surface-area phosphor material. It can be solubilized with excess oxidants (e.g., hypochlorite solution) and stabilized by complexation with halide ions. Soluble mercury in dechlorinated saline solution is effectively removed by cementation with zero-valent iron in the form of steel wool. In packed column dynamic flow testing, soluble mercury was reduced to mercury metal and insoluble calomel, loading > 1.2 g of mercury per grain of steel wool before an appreciable breakthrough of soluble mercury in the effluent.

Bostick, W.D.; Beck, D.E.; Bowser, K.T. [and others

1996-02-01T23:59:59.000Z

202

Determination of mercury distribution inside spent compact fluorescent lamps by atomic absorption spectrometry  

Science Conference Proceedings (OSTI)

Highlights: Black-Right-Pointing-Pointer New treatments for CFL are required considering the aim of Directive 202/96/CE. Black-Right-Pointing-Pointer It is shown that most of the mercury introduced into a CFL is in the phosphor powder. Black-Right-Pointing-Pointer Experimental conditions for microwave-assisted sample digestion followed by AAS measurements are described. Black-Right-Pointing-Pointer By washing the glass it is possible to reduce the concentration below legal limits. - Abstract: In this study, spent compact fluorescent lamps were characterized to determine the distribution of mercury. The procedure used in this research allowed mercury to be extracted in the vapor phase, from the phosphor powder, and the glass matrix. Mercury concentration in the three phases was determined by the method known as cold vapor atomic absorption spectrometry. Median values obtained in the study showed that a compact fluorescent lamp contained 24.52 {+-} 0.4 ppb of mercury in the vapor phase, 204.16 {+-} 8.9 ppb of mercury in the phosphor powder, and 18.74 {+-} 0.5 ppb of mercury in the glass matrix. There are differences in mercury concentration between the lamps since the year of manufacture or the hours of operation affect both mercury content and its distribution. The 85.76% of the mercury introduced into a compact fluorescent lamp becomes a component of the phosphor powder, while more than 13.66% is diffused through the glass matrix. By washing and eliminating all phosphor powder attached to the glass surface it is possible to classified the glass as a non-hazardous waste.

Rey-Raap, Natalia [Departamento de Ingenieria Mecanica y Construccion, Universitat Jaume I de Castellon, Av. de Vicent Sos Baynat s/n, 12071 Castellon de la Plana, Espana (Spain); Gallardo, Antonio, E-mail: gallardo@emc.uji.es [Departamento de Ingenieria Mecanica y Construccion, Universitat Jaume I de Castellon, Av. de Vicent Sos Baynat s/n, 12071 Castellon de la Plana, Espana (Spain)

2012-05-15T23:59:59.000Z

203

Integrated-circuit control for two-lamp electronic ballast. Final report  

SciTech Connect

Circuitry is described for a solid-state, high-frequency fluorescent ballast designed to operate two F40 T-12 rapid-start lamps. The circuits are designed to be produced by hybrid integrated circuit (IC) technology. The signal components are produced on a single IC chip; the power transistors are attached to an alumina substrate. The initial IC version reduces the component count by about 50%. The cost of each IC in 500K lots is $0.70, replacing discrete parts costing $2.25. Additional savings of more than $1.00 per unit are realized by the decreased assembly time and improved reliability of the ICs. The system performance (two-lamp F40) was compared to the discrete version of the ballast and to an efficient core-coil ballast and found to be 6% less and 20% more efficient, respectively. The decrease in efficiency relative to the discrete version of the ballast is due to retaining some power to the filaments during operation in order to maintain normal lamp life.

Kohler, T.P.

1982-11-01T23:59:59.000Z

204

Experimental and theoretical investigations on the warm-up of a high-pressure mercury discharge lamp  

SciTech Connect

Modern high-pressure discharge lamps are forced to provide instant light and hot relight capabilities - if possible at lower power units. A detailed understanding of the warm-up of high-pressure discharge lamps is therefore required. Complex fluid model codes were developed for the past years including more and more processes like two-dimensional treatment of convection trying to provide a more comprehensive and consistent description of high-pressure discharge lamps. However, there is a lack of experimental data to examine the performance of these models. This work provides a very complete set of geometrical, electrical, spectroscopic, and thermographic data according to the warm-up of a high-pressure mercury discharge lamp that is compared to the results of a state of the art fluid code. Quantitative agreement is achieved for single parameters like wall temperatures. But the paper also reveals the need for further investigations and improvements of the code.

Zalach, J.; Franke, St.; Schoepp, H. [Leibniz Institute for Plasma Science and Technology, Felix-Hausdorff-Str. 2, D-17489 Greifswald (Germany); Araoud, Z.; Charrada, K. [Unite d'Etude des Milieux Ionises et Reactifs, IPEIM, rte de Kairouan, 5019 Monastir (Tunisia); Zissis, G. [Laboratoire Plasma et Conversion d'Energie, 118 rte Narbonne, Bat3R2, 31062 Toulouse (France)

2011-03-15T23:59:59.000Z

205

A New Rb Lamp Exciter Circuit for Rb atomic clocks and Studies on Transition from Ring to Red mode  

E-Print Network (OSTI)

In this paper we describe the development of novel RF exciter circuit for electrode less Rb lamp. The lamp exciter circuit is a RF oscillator with a a new configuration operating at 60 to 65 MHz frequency with 3 to 4 watt power. The Rb lamp is used in exciting the ground state hyperfine transitions in Rb atom in a glass cell placed inside a tuned microwave cavity, As the frequency of these hyperfine transitions is very stable it is used in the development of Rb atomic clock by phase locking the oven controlled crystal oscillator (OCXO) to this atomic transition frequency. The details of the Rb lamp exciter are presented in the paper.The Lamp is ideally operated in ring mode as in this mode the linewidth is narrow and there is no self reversal. However, high temperature and RF excitation power may drive the Rb lamp to red mode which gives rise to line broadening and self reversal. It is the experience that mode change from ring to red deteriorates the atomic signal strength and S/N. In this paper the reasons of mode change are also discussed.

Savita Singh; Bikash Ghosal; G M Saxena

2010-11-10T23:59:59.000Z

206

Standards, Ethics  

NLE Websites -- All DOE Office Websites (Extended Search)

Standards, Ethics Ombuds Standards and Ethics Committed to the fair and equitable treatment of all employees, contractors, and persons doing business with the Laboratory. Contact...

207

Find Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

may not be available from IHS: AHRI standards - from the Air Conditioning, Heating, and Refrigeration Institute AISC standards - from the American Institute of Steel Construction...

208

The Jamming point street-lamp in the world of granular media  

E-Print Network (OSTI)

The Jamming of soft spheres at zero temperature, the J-point, has been extensively studied both numerically and theoretically and can now be considered as a safe location in the space of models, where a street lamp has been lit up. However, a recent work by Ikeda et al, 2013 reveals that, in the Temperature/Packing fraction parameter space, experiments on colloids are actually rather far away from the scaling regime illuminated by this lamp. Is it that the J-point has little to say about real system? What about granular media? Such a-thermal, frictional, systems are a-priori even further away from the idealized case of thermal soft spheres. In the past ten years, we have systematically investigated horizontally shaken grains in the vicinity of the Jamming transition. We discuss the above issue in the light of very recent experimental results. First, we demonstrate that the contact network exhibits a remarkable dynamics, with strong heterogeneities, which are maximum at a packing fraction phi star, distinct and smaller than the packing fraction phi dagger, where the average number of contact per particle starts to increase. The two cross-overs converge at point J in the zero mechanical excitation limit. Second, a careful analysis of the dynamics on time scales ranging from a minute fraction of the vibration cycle to several thousands of cycles allows us to map the behaviors of this shaken granular system onto those observed for thermal soft spheres and demonstrate that some light of the J-point street-lamp indeed reaches the granular universe.

Corentin Coulais; Robert P. Behringer; Olivier Dauchot

2013-05-03T23:59:59.000Z

209

Super-radiance in the sodium resonance lines from sodium iodide arc lamps  

Science Conference Proceedings (OSTI)

Super-radiance observed within the centers of the sodium resonance D lines emitted by arc lamps containing sodium iodide as additive in a high-pressure mercury plasma environment was studied by high-resolution emission spectroscopy. The spectral radiance of these self-reversed lines including super-radiance was simulated by considering a local enhancement of the source function due to the presence of an additional source of radiation near the arc wall. Causes of this hitherto unrecognized source of radiation are given.

Karabourniotis, D. [Department of Physics, Institute of Plasma Physics, University of Crete, 71003 Heraklion (Greece); Drakakis, E. [Department of Electrical Engineering, Technological Educational Institute, Heraklion (Greece)

2010-08-09T23:59:59.000Z

210

A high-efficiency indirect lighting system utilizing the solar 1000 sulfur lamp  

SciTech Connect

High-lumen light sources represent unique challenges and opportunities for the design of practical and efficient interior lighting systems. High-output sources require a means of large-scale distribution and avoidance of high-luminance glare while providing efficient delivery. An indirect lighting system has been developed for use with a 1,000 Watt sulfur lamp that efficiently utilizes the high-output source to provide quality interior lighting. This paper briefly describes the design and initial testing of this new system.

Siminovitch, M.; Gould, C.; Page, E.

1997-06-01T23:59:59.000Z

211

Strategic Standardization  

Science Conference Proceedings (OSTI)

... Program Strategic Standardization Curriculum (CMGT 564 - 2010) ... com. Curriculum ks eport, 1992), Grading (Research paper, ...

2012-12-03T23:59:59.000Z

212

Hardness Standardization  

Science Conference Proceedings (OSTI)

... metallic products. NIST produces a variety of hardness Standard Reference Materials (SRMs) for industry. The NIST ...

2013-08-20T23:59:59.000Z

213

Method of controlling the mercury vapor pressure in a photo-chemical lamp or vapor filter used for Hg.sup.196 enrichment  

DOE Patents (OSTI)

The present invention is directed to a method of eliminating the cold spot zones presently used on Hg.sup.196 isotope separation lamps and filters by the use of a mercury amalgams, preferably mercury - indium amalgams. The use of an amalgam affords optimization of the mercury density in the lamp and filter of a mercury enrichment reactor, particularly multilamp enrichment reactors. Moreover, the use of an amalgam in such lamps and/or filters affords the ability to control the spectral line width of radiation emitted from lamps, a requirement for mercury enrichment.

Grossman, Mark W. (Belmont, MA)

1993-01-01T23:59:59.000Z

214

Method of controlling the mercury vapor pressure in a photo-chemical lamp or vapor filter used for Hg[sup 196] enrichment  

DOE Patents (OSTI)

The present invention is directed to a method of eliminating the cold spot zones presently used on Hg[sup 196] isotope separation lamps and filters by the use of a mercury amalgams, preferably mercury - indium amalgams. The use of an amalgam affords optimization of the mercury density in the lamp and filter of a mercury enrichment reactor, particularly multilamp enrichment reactors. Moreover, the use of an amalgam in such lamps and/or filters affords the ability to control the spectral line width of radiation emitted from lamps, a requirement for mercury enrichment.

Grossman, M.W.

1993-02-16T23:59:59.000Z

215

DOE technical standards list: Department of Energy standards index  

Science Conference Proceedings (OSTI)

This technical standards list (TSL) was prepared for use by personnel involved in the selection and use of US DOE technical standards and other government and non-government standards. This TSL provides listings of current DOE technical standards, non-government standards that have been adopted by DOE, other government documents in which DOE has a recorded interest, and cancelled DOE technical standards. Standards are indexed by type in the appendices to this document. Definitions of and general guidance for the use of standards are also provided.

NONE

1997-06-01T23:59:59.000Z

216

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

certain lighting system components, but with only minor exceptions (torchieres, ceiling fan light kits, exit signs, traffic signals, and metal halide lamp fixtures), has not...

217

ANSI N42.42 Standard  

Science Conference Proceedings (OSTI)

... requirements for these types of instruments are described in other standards. ... The ANSI/IEEE standard does not address instrument control, data ...

2013-06-05T23:59:59.000Z

218

Appliance and Equipment Energy Efficiency Standards | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Appliance and Equipment Energy Efficiency Standards Appliance and Equipment Energy Efficiency Standards Program Information Oregon Program Type ApplianceEquipment Efficiency...

219

Defining a Standard Metric for Electricity Savings  

NLE Websites -- All DOE Office Websites (Extended Search)

Defining a Standard Metric for Electricity Savings Title Defining a Standard Metric for Electricity Savings Publication Type Report LBNL Report Number LBNL-2213E Year of...

220

Energy Optimization Standard | Open Energy Information  

Open Energy Info (EERE)

Last modified on October 10, 2012. Rules Regulations Policies Program Place Michigan Name Energy Optimization Savings Standard Incentive Type Energy Efficiency Resource Standard...

Note: This page contains sample records for the topic "lamp type standard" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Approved DOE Technical Standards  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

approved-doe-technical-standards Forrestal Building approved-doe-technical-standards Forrestal Building 1000 Independence Avenue, SW Washington, DC 205851.800.dial.DOE en DOE-STD-1150-2013 http://energy.gov/hss/downloads/doe-std-1150-2013 DOE-STD-1150-2013

222

Energy Savings and NOx Emissions Reduction Potential from the 2012 Federal Legislation to Phase Out Incandescent Lamps in Texas  

E-Print Network (OSTI)

This report provides detailed information about the potential savings from the 2012 Federal Legislation to phase out incandescent lamps and the NOx emissions reduction from the replacement of incandescent bulbs with Compact Fluorescent Lamps (CFL). In Texas, this analysis includes the savings estimates from both the annual and Ozone Season Day (OSD) NOx reductions. The NOx emissions reduction in this analysis are calculated using estimated emissions factors for 2007 from the US Environmental Protection Agency (US EPA) eGRID database, which had been specially prepared for this purpose.

Liu, Zi; Baltazar, Juan Carlos; Haberl, Jeff; Soman, Rohit

2010-03-01T23:59:59.000Z

223

Types of Thermocouples  

Science Conference Proceedings (OSTI)

Table 1   Properties of standard thermocouples...Table 1 Properties of standard thermocouples Type Thermoelements Base composition Melting point, °C Resisivity nΩ · m Recommended

224

THERMAL ANNEALING OF ZNO FILMS USING HIGH-DENSITY PLASMA ARC LAMPS  

Science Conference Proceedings (OSTI)

Nanostructured materials are rarely synthesized with appropriate phase and/or morphology. In this study, critical additional of as-synthesized nanostructured materials, such as annealing and/or activation of dopants, are addressed using infrared plasma arc lamps (PAL) over areas as large as 1,000 cm2. The broad spectral range of the PAL and the spectral variation of light absorption in nanostructured materials make the selection of processing parameters extremely difficult, posing a major technological barrier. In this study, the measurement of the surface temperature using various techniques for ZnO films on crystalline silicon wafers is discussed. An energy transport model for the simulation of rapid thermal processing using PAL is presented. The experimental and computational results show that the surface temperature cannot be measured directly and that computer simulation results are an effective tool for obtaining accurate data on processing temperatures.

Sabau, Adrian S [ORNL; Dinwiddie, Ralph Barton [ORNL; Xu, Jun [ORNL; Angelini, Joseph Attilio [ORNL; Harper, David C [ORNL

2011-01-01T23:59:59.000Z

225

NIST energy related inventions: Electronic starter device for fluorescent lamps. Interim report, August--October, 1997  

SciTech Connect

From the Scope of Work document which accompanied the original proposal, three silicon devices were anticipated for development, simulation, and quality assurance fabrication. The status of these are in the same format as the Scope of Work...Attachment-A-: Task 1--design and simulation; Task 2--prototype tooling; Task 3--test engineering; Task 4--product tooling; Task 5--package tooling/manufacturing design and assembly. It is felt the program will meet it`s stated goals of producing a low cost, high performance fluorescent lamp starter which will lower the acquisition and operating cost of fluorescent technology...thus saving significant amounts of energy. The likelihood of success is even greater, now that the TN22 component has been qualified. The challenges of creating a custom ASIC, while still significant, are within the skill and expertise level or the assigned engineers.

Johnson, S.A.

1997-12-01T23:59:59.000Z

226

Mercury reduction studies to facilitate the thermal decontamination of phosphor powder residues from spent fluorescent lamps  

SciTech Connect

This work investigates the thermal release of mercury from phosphor powder of spent fluorescent lamps. The treatment conditions and the ability of various reducing agents (primarily sodium borohydride) to lower the overall heating temperature required to improve the release of Hg have been evaluated. Hg species in samples were monitored in a thermal desorption atomic absorption spectrometer system, and total mercury was analyzed in a cold vapor atomic absorption spectrometer. Sodium borohydride was the best reducing agent among the ones studied. However, citric acid presented a high capacity to weaken mercury bonds with the matrix. When the sample was crushed with sodium borohydride for 40 min in a mass ratio of 10:1 (sample:reducing agent) and submitted to thermal treatment at 300 deg. C for 2 h, the concentration of mercury in a phosphor powder sample with 103 mg kg{sup -1} of mercury reached 6.6 mg kg{sup -1}.

Alves Durao, Walter [Chemistry Department, Federal University of Minas Gerais (UFMG), Cidade Universitaria 30.123-970 Belo Horizonte, MG (Brazil); Andreva de Castro, Camila [Chemistry Engineering Department, Federal University of Minas Gerais (UFMG) (Brazil); Carvalhinho Windmoeller, Claudia [Chemistry Department, Federal University of Minas Gerais (UFMG), Cidade Universitaria 30.123-970 Belo Horizonte, MG (Brazil)], E-mail: claucw@netuno.lcc.ufmg.br

2008-11-15T23:59:59.000Z

227

Archaeological data visualization in VR: analysis of lamp finds at the great temple of petra, a case study  

Science Conference Proceedings (OSTI)

We present the results of an evaluation of the ARCHAVE system, an immersive virtual reality environment for archaeological research. ARCHAVE is implemented in a Cave. The evaluation studied researchers analyzing lamp and coin finds throughout the excavation ... Keywords: archaeological data analysis, immersive virtual reality interfaces, scientific visualization

Daniel Acevedo; Eileen Vote; David H. Laidlaw; Martha S. Joukowsky

2001-10-01T23:59:59.000Z

228

Conservation Standards Enforcement | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

November 20, 2012 November 20, 2012 Teddico: Noncompliance Determination (2012-SE-5409) DOE issued a Notice of Noncompliance Determination to The Electrical Design, Development and Implementation Company d/b/a Teddico finding that a variety of basic models of magnetic probe-start metal halide lamp fixtures do not comport with the energy conservation standards. November 19, 2012 Hydac: Noncompliance Determination (2012-SE-4107) DOE issued a Notice of Noncompliance Determination to Hydac Technology Corporation finding that a variety of electric motor basic models do not comport with the energy conservation standards. November 7, 2012 YMGI: Order (2011-SCE-1605) DOE ordered YMGI Group LLC to pay a $31,400 civil penalty after finding (1) YMGI had failed to certify that certain models of residential central air

229

WELDING STANDARDS  

SciTech Connect

Hanford Atomic Production Operation specification guides and standards for welding and brazing are presented. Details of this manual are given in TID- 4100 (Suppl.). (N.W.R.)

1963-01-01T23:59:59.000Z

230

Property:RenewableFuelStandard/Year | Open Energy Information  

Open Energy Info (EERE)

RenewableFuelStandard/Year RenewableFuelStandard/Year Jump to: navigation, search This is a property of type Date. Pages using the property "RenewableFuelStandard/Year" Showing 15 pages using this property. R Renewable Fuel Standard Schedule + 2022 + Renewable Fuel Standard Schedule + 2016 + Renewable Fuel Standard Schedule + 2010 + Renewable Fuel Standard Schedule + 2017 + Renewable Fuel Standard Schedule + 2011 + Renewable Fuel Standard Schedule + 2018 + Renewable Fuel Standard Schedule + 2012 + Renewable Fuel Standard Schedule + 2019 + Renewable Fuel Standard Schedule + 2013 + Renewable Fuel Standard Schedule + 2020 + Renewable Fuel Standard Schedule + 2014 + Renewable Fuel Standard Schedule + 2008 + Renewable Fuel Standard Schedule + 2021 + Renewable Fuel Standard Schedule + 2015 +

231

Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Standards Interconnection Standards Interconnection Standards < Back Eligibility Commercial Fed. Government Industrial Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Buying & Making Electricity Solar Wind Program Info State Nevada Program Type Interconnection Provider Public Utilities Commission of Nevada In December 2003, the Nevada Public Utilities Commission (PUC) adopted interconnection standards for customers of NV Energy (formerly Nevada Power and Sierra Pacific Power) with on-site generation up to 20 megawatts (MW) in capacity. These standards are largely consistent with IEEE 1547 standards, California's interconnection rule (California Rule 21) and the model interconnection agreement developed by the National Association of

232

Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Standards Interconnection Standards Interconnection Standards < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Energy Sources Solar Home Weatherization Wind Program Info State Pennsylvania Program Type Interconnection Provider Pennsylvania Public Utility Commission The Pennsylvania Public Utilities Commission was required to adopt interconnection standards and net-metering rules by the Alternative Energy Portfolio Standards Act of 2004.The PUC subsequently adopted interconnection standards for net-metered distributed generation (DG)

233

Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Standards Interconnection Standards Interconnection Standards < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Wind Energy Sources Solar Home Weatherization Water Program Info State North Carolina Program Type Interconnection Provider North Carolina Utilities Commission The North Carolina Utilities Commission (NCUC) adopted comprehensive interconnection standards for distributed generation in June 2008. The NCUC standards, which are similar to the Federal Energy Regulatory Commission's (FERC) interconnection standards for small generators,

234

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Low-Voltage Dry-Type Distribution Transformers Energy Conservation Standard Low-Voltage Dry-Type Distribution Transformers Energy Conservation Standard Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has completed a rulemaking to amend the current energy conservation standards for liquid-immersed, medium-voltage dry-type, and low-voltage dry-type distribution transformers. This activity is mandated by the Energy Policy and Conservation Act (EPCA). Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a final rule regarding amended energy efficiency standards for liquid-immersed, medium-voltage dry-type, and low-voltage dry-type distribution transformers. 78 FR 23335 (April 18, 2013). The distribution transformers final rule was the DOE's first "negotiated rulemaking," conducted under the Federal Advisory Committee Act and the Negotiated Rulemaking Act.

235

The virtual observatory service TheoSSA: Establishing a database of synthetic stellar flux standards. I. NLTE spectral analysis of the DA-type white dwarf G 191-B2B  

E-Print Network (OSTI)

H-rich, DA-type white dwarfs are particularly suited as primary standard stars for flux calibration. State-of-the-art NLTE models consider opacities of species up to trans-iron elements and provide reliable synthetic stellar-atmosphere spectra to compare with observation. We establish a database of theoretical spectra of stellar flux standards that are easily accessible via a web interface. In the framework of the Virtual Observatory, the German Astrophysical Virtual Observatory developed the registered service TheoSSA. It provides easy access to stellar spectral energy distributions (SEDs) and is intended to ingest SEDs calculated by any model-atmosphere code. In case of the DA white dwarf G 191-B2B, we demonstrate that the model reproduces not only its overall continuum shape but also the numerous metal lines exhibited in its ultraviolet spectrum. TheoSSA is in operation and contains presently a variety of SEDs for DA white dwarfs. It will be extended in the near future and can host SEDs of all primary and ...

Rauch, T; Kruk, J W; Werner, K

2013-01-01T23:59:59.000Z

236

EOS standards  

SciTech Connect

An approach to creating accurate EOS for pressure standards is described. Applications to Cu, Au, and Ta are shown. Extension of the method to high compressions using DFT is illustrated. Comparisons with modern functionals show promise.

Greeff, Carl W [Los Alamos National Laboratory

2011-01-12T23:59:59.000Z

237

Application of a three-dimensional model for a study of the energy transfer of a high-pressure mercury horizontal lamp  

Science Conference Proceedings (OSTI)

This paper is devoted to study the dynamics of a discharge lamp with high intensity in a horizontal position. As an example of application, we chose the high-pressure mercury lamp. For this, we realized a three-dimensional model, a stable and powered DC. After the validation of this model, we used it to reproduce the influence of some parameters that have appeared on major transport phenomena of mass and energy in studying the lamp operating in a horizontal position. Indeed, the mass of mercury and the electric current are modified and the effect of convective transport is studied.

Ben Hamida, M. B.; Charrada, K. [Unite d'Etude des Milieux Ionises et Reactifs, IPEIM, 5019 route de Kairouan Monastir (Tunisia)

2012-06-15T23:59:59.000Z

238

Global residential appliance standards  

SciTech Connect

In most countries, residential electricity consumption typically ranges from 20% to 40% of total electricity consumption. This energy is used for heating, cooling, refrigeration and other end-uses. Significant energy savings are possible if new appliance purchases are for models with higher efficiency than that of existing models. There are several ways to ensure or encourage such an outcome, for example, appliance rebates, innovative procurement, and minimum efficiency standards. This paper focuses on the latter approach. At the present time, the US is the only country with comprehensive appliance energy efficiency standards. However, many other countries, such as Australia, Canada, the European Community (EC), Japan and Korea, are considering enacting standards. The greatest potential impact of minimum efficiency standards for appliances is in the developing countries (e.g., China and India), where saturations of household appliances are relatively low but growing rapidly. This paper discusses the potential savings that could be achieved from global appliance efficiency standards for refrigerators and freezers. It also could be achieved from global appliance efficiency standards for refrigerators and freezers. It also discusses the impediments to establishing common standards for certain appliance types, such as differing test procedures, characteristics, and fuel prices. A methodology for establishing global efficiency standards for refrigerators and freezers is described.

Turiel, I.; McMahon, J.E. [Lawrence Berkeley Lab., CA (US); Lebot, B. [Agence Francaise pour la Maitrise de l`Energie, Valbonne (FR)

1993-03-01T23:59:59.000Z

239

(Terminology standardization)  

SciTech Connect

Terminological requirements in information management was but one of the principal themes of the 2nd Congress on Terminology and Knowledge Engineering. The traveler represented the American Society for Testing and Materials' Committee on Terminology, of which he is the Chair. The traveler's invited workshop emphasized terminology standardization requirements in databases of material properties as well as practical terminology standardizing methods. The congress included six workshops in addition to approximately 82 lectures and papers from terminologists, artificial intelligence practitioners, and subject specialists from 18 countries. There were approximately 292 registrants from 33 countries who participated in the congress. The congress topics were broad. Examples were the increasing use of International Standards Organization (ISO) Standards in legislated systems such as the USSR Automated Data Bank of Standardized Terminology, the enhanced Physics Training Program based on terminology standardization in Physics in the Chinese province of Inner Mongolia, and the technical concept dictionary being developed at the Japan Electronic Dictionary Research Institute, which is considered to be the key to advanced artificial intelligence applications. The more usual roles of terminology work in the areas of machine translation. indexing protocols, knowledge theory, and data transfer in several subject specialties were also addressed, along with numerous special language terminology areas.

Strehlow, R.A.

1990-10-19T23:59:59.000Z

240

Method and apparatus for mounting a dichroic mirror in a microwave powered lamp assembly using deformable tabs  

DOE Patents (OSTI)

A microwave powered electrodeless lamp includes an improved screen unit having mesh and solid sections with an internal reflector secured at the juncture of the two sections to reflect light into a light-transmitting chamber defined in the lamp microwave cavity by the reflector and the mesh section. A discharge envelope of a bulb is disposed in the light-transmitting chamber. Light emitted from the envelope is prevented by the reflector from entering the cavity portion bounded by the solid section of the screen. The reflector is mounted in the cavity by tabs formed in the screen unit and bendable into the cavity to define support planes abutting respective surfaces of the reflector. The mesh section and tabs are preferably formed by etching a thin metal sheet. 7 figs.

Ury, M.; Sowers, F.; Harper, C.; Love, W.

1998-11-24T23:59:59.000Z

Note: This page contains sample records for the topic "lamp type standard" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Method and apparatus for mounting a dichroic mirror in a microwave powered lamp assembly using deformable tabs  

DOE Patents (OSTI)

A microwave powered electrodeless lamp includes an improved screen unit having mesh and solid sections with an internal reflector secured at the juncture of the two sections to reflect light into a light-transmitting chamber defined in the lamp microwave cavity by the reflector and the mesh section. A discharge envelope of a bulb is disposed in the light-transmitting chamber. Light emitted from the envelope is prevented by the reflector from entering the cavity portion bounded by the solid section of the screen. The reflector is mounted in the cavity by tabs formed in the screen unit and bendable into the cavity to define support planes abutting respective surfaces of the reflector. The mesh section and tabs are preferably formed by etching a thin metal sheet.

Ury, Michael (Bethesda, MD); Sowers, Frank (Frederick, MD); Harper, Curt (Wheaton, MD); Love, Wayne (Olney, MD)

1998-01-01T23:59:59.000Z

242

Standards Coordination Office Homepage  

Science Conference Proceedings (OSTI)

Standards Coordination Office. ... About the Standards Coordination Office (SCO). The Standards Coordination Office of the ...

2013-07-31T23:59:59.000Z

243

Standard Modeling  

NLE Websites -- All DOE Office Websites (Extended Search)

Standard no es suficiente Standard no es suficiente Avanzar Volver Principal ESTOY PERDIDO!!! Si bien el Modelo Standard proporciona una descripción muy buena de los fenómenos observados en los experimentos, todavía es una teoría incompleta. El problema es que el Modelo Standard no puede explicar la causa por la que existen algunas partículas, del modo en que lo hacen. Por ejemplo, aún cuando los físicos conocían las masas de todos los quarks, a excepción de la del quark top desde hace muchos años, no podían simplemente predecir en forma exacta la masa del top, sin utilizar evidencia experimental, dado que el Modelo Standard carece de un modelo matemático para calcular el patrón que siguen los valores de las masas de las partículas. Otra cuestión está relacionada con el hecho que existen tres pares de

244

Mechanical design of PlayLamp : a minimally intrusive device for recording the behavior of children at-risk of developmental disorders  

E-Print Network (OSTI)

This thesis paper documents the design process, decisions, and outcomes of the design of the physical form factor of PlayLamp, a device for video and audio recording the development of children at-risk of having developmental ...

Steger, Stephen Andrew

2008-01-01T23:59:59.000Z

245

Synchrophasor Standards  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Development & Support Development & Support Kenneth Martin martin@electricpowergroup.com June 27-28, 2013 Washington, DC DOE/OE Transmission Reliability Program 2 Introduction  Synchrophasor measurement systems widely deployed  Enable a new generation of power system monitor & control capability - Improved power system analysis & system models - Wide area, high-resolution visibility - Basis for a new generation of controls  Research challenge - standards to enable interoperability - Measurement performance - Communications  Research focus - facilitate development, testing, and validation of standards to promote interoperability Basic phasor concept well known . A phasor is the complex form of the AC waveform √2 A cos (2 π ω 0 t + φ) A e

246

Safety Standards  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

US DOE Workshop US DOE Workshop September 19-20, 2012 International perspective on Fukushima accident Miroslav Lipár Head, Operational Safety Section M.Lipar@iaea.org +43 1 2600 22691 2 Content * The IAEA before Fukushima -Severe accidents management * The IAEA actions after Fukushima * The IAEA Action plan on nuclear safety * Measures to improve operational safety * Conclusions THE IAEA BEFORE FUKUSHIMA 4 IAEA Safety Standards IAEA Safety Standards F undamental S afety Principles Safety Fundamentals f o r p ro te c ti n g p e o p l e a n d t h e e n v i ro n m e n t IAEA Safety Standards Regulations for the Safe Transport of Radioactive Material 2005 E dit ion Safety Requirements No. T S-R-1 f o r p ro te c ti n g p e o p l e a n d t h e e n v i ro n m e n t IAEA Safety Standards Design of the Reactor Core for Nuclear Power Plants

247

STANDARD REFERENCE  

E-Print Network (OSTI)

The profession is strongly urged to use the standard reference on the financial framework in the EU, concerning endorsed IFRS in order to give a clear message to the market and to users of financial statements in and outside the EU.

unknown authors

2005-01-01T23:59:59.000Z

248

Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Standards Interconnection Standards Interconnection Standards < Back Eligibility Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Wind Energy Sources Solar Home Weatherization Program Info State Michigan Program Type Interconnection Provider Michigan Public Service Commission The Michigan Public Service Commission (PSC) first adopted interconnection standards for distributed generation (DG) in September 2003. The original standards provided for 5 levels of interconnection with cutoffs at 30 kilowatts (kW), 150 kW, 750 kW, and 2 megawatts (MW), but left many details

249

Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Standards Interconnection Standards Interconnection Standards < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Solar Wind Program Info State Oregon Program Type Interconnection Provider Oregon Public Utility Commission Oregon has three separate interconnection standards: one for net-metered systems, one for small generator facilities (non-net metered systems) and one for large generator facilities (non-net metered systems). Oregon has also established separate net metering requirements and interconnection standards for the state's primary investor-owned utilities (PGE and

250

Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Standards Interconnection Standards Interconnection Standards < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Multi-Family Residential Nonprofit Residential Schools State Government Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Solar Water Wind Program Info State New Jersey Program Type Interconnection Provider New Jersey Board of Public Utilities New Jersey's interconnection standards apply statewide to all electric distribution utilities, but not to the small number of municipal utilities and electric cooperatives in the state. The rules, first adopted in 2001, have been revised several times since their inception, most recently in May 2012. The current standards include the following basic provisions:

251

Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Standards Interconnection Standards Interconnection Standards < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Wind Energy Sources Solar Home Weatherization Program Info State District of Columbia Program Type Interconnection Provider Washington Utilities and Transportation Commission In September 2007, the Washington Utilities and Transportation Commission (UTC) adopted interconnection standards for distributed generation (DG) systems up to 20 megawatts (MW) in capacity. The revised standards provide for two separate levels of interconnection based on system capacity. The

252

Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Standards Interconnection Standards Interconnection Standards < Back Eligibility Agricultural Commercial Industrial Institutional Nonprofit Residential Schools Utility Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Wind Energy Sources Solar Program Info State Colorado Program Type Interconnection Provider Colorado Public Utilities Commission In December 2005, the Colorado Public Utilities Commission (PUC) adopted standards for net metering and interconnection, as required by Amendment 37, a renewable-energy ballot initiative approved by Colorado voters in November 2004. The PUC standards generally apply to utilities with 40,000 or more customers and all cooperative utilities.*

253

Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Standards Interconnection Standards Interconnection Standards < Back Eligibility Commercial Fed. Government Industrial Institutional Local Government Low-Income Residential Multi-Family Residential Nonprofit Residential Schools State Government Savings Category Bioenergy Biofuels Alternative Fuel Vehicles Commercial Heating & Cooling Manufacturing Buying & Making Electricity Hydrogen & Fuel Cells Water Wind Energy Sources Solar Home Weatherization Program Info State Wisconsin Program Type Interconnection Provider Public Service Commission of Wisconsin In February 2004, the Wisconsin Public Service Commission adopted interconnection standards for distributed generation (DG) systems up to 15 megawatts (MW) in capacity. All investor-owned utilities (IOUs) and municipal utilities are required to abide by the standard provisions.

254

Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Standards Interconnection Standards Interconnection Standards < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Wind Energy Sources Solar Program Info State New York Program Type Interconnection Provider New York State Department of Public Service New York first adopted uniform interconnection standards in 1999 (see history below). The Standard Interconnection Requirements (SIR) have subsequently been amended several times since, most recently with the adoption of far reaching revisions in February 2009. Several more minor

255

Observed Minimum Illuminance Threshold for Night Market Vendors in Kenya who use LED Lamps  

Science Conference Proceedings (OSTI)

Creation of light for work, socializing, and general illumination is a fundamental application of technology around the world. For those who lack access to electricity, an emerging and diverse range of LED based lighting products hold promise for replacing and/or augmenting their current fuel-based lighting sources that are costly and dirty. Along with analysis of environmental factors, economic models for total cost-ofownership of LED lighting products are an important tool for studying the impacts of these products as they emerge in markets of developing countries. One important metric in those models is the minimum illuminance demanded by end-users for a given task before recharging the lamp or replacing batteries. It impacts the lighting service cost per unit time if charging is done with purchased electricity, batteries, or charging services. The concept is illustrated in figure 1: LED lighting products are generally brightest immediately after the battery is charged or replaced and the illuminance degrades as the battery is discharged. When a minimum threshold level of illuminance is reached, the operational time for the battery charge cycle is over. The cost to recharge depends on the method utilized; these include charging at a shop at a fixed price per charge, charging on personal grid connections, using solar chargers, and purchasing dry cell batteries. This Research Note reports on the observed"charge-triggering" illuminance level threshold for night market vendors who use LED lighting products to provide general and task oriented illumination. All the study participants charged with AC power, either at a fixed-price charge shop or with electricity at their home.

Johnstone, Peter; Jacobson, Arne; Mills, Evan; Radecsky, Kristen

2009-03-21T23:59:59.000Z

256

GLASS AND GLASS-DERIVATIVE SEALS FOR USE IN ENERGY-EFFICIENT FUEL CELLS AND LAMPS  

DOE Green Energy (OSTI)

As the project approaches the end of the first year, the materials screening components of the work are ahead of schedule, while all other tasks are on schedule. For solid oxide fuel cells (SOFC), a series of 16 sealing glasses have been prepared and characterized. Traditional melting was used to prepare all of the glasses, and the sol-gel approach has been used to prepare some of the glasses as well as other compositions that might be viable because of the low processing temperatures afforded by the sol-gel method. The glass characterization included measurements of the viscosity and thermal expansion of the glasses, as well as the thermal expansion of the partly crystalline glass ceramics. In addition, the wetting and sintering behavior of all glasses has been measured, as well as the crystallization behavior. The time and temperature at which crystalline phases form from the glasses has been determined for all of the glasses. Each glass ceramic contains at least two crystalline phases, and most of the crystalline phases have been positively identified. Room temperature leak testing has been completed for all sealants, and experiments are in progress to determine the DC electrochemical degradation and degradation in wet hydrogen. The second component of the work, focused on seals for higher-temperature discharge lighting, has focused on determining the phase relations in the yttria--alumina--silica system at various silica levels. Again, traditional melting and sol-gel synthesis have been employed, and the sol-gel method was successful for preparing new phases that were discovered during the work. High temperature diffraction and annealing studies have clarified the phase relations for the samples studies, although additional work remains. Four new phases have been identified and synthesized in pure form, from which full structure solutions were obtained as well as the anisotropic thermal expansion for each phase. Functional testing of lamps are on on-going and will be analyzed during year 2 of the contract.

Scott Misture; Arun Varshneya; Matthew Hall; Sylvia DeCarr; Steve Bancheri

2004-08-15T23:59:59.000Z

257

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Light-Emitting Diode Lamps Test Procedure Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) is establishing test procedures for...

258

Energy Standard  

Gasoline and Diesel Fuel Update (EIA)

Hall Hall October 2011 Analysis of Impacts of a Clean www.eia.gov U.S. Department of Energy Washington, DC 20585 This report was prepared by the U.S. Energy Information Administration (EIA), the statistical and analytical agency within the U.S. Department of Energy. By law, EIA's data, analyses, and forecasts are independent of approval by any other officer or employee of the United States Government. The views in this report therefore should not be construed as representing those of the U.S. Department of Energy or other Federal agencies. U.S. Energy Information Administration | Analysis of Impacts of a Clean Energy Standard as requested by Chairman Hall i Contacts This report, Analysis of Impacts of a Clean Energy Standard as requested by Chairman Hall, was prepared under the

259

Energy Standard  

Gasoline and Diesel Fuel Update (EIA)

Bingaman Bingaman November 2011 Analysis of Impacts of a Clean www.eia.gov U.S. Department of Energy Washington, DC 20585 This report was prepared by the U.S. Energy Information Administration (EIA), the statistical and analytical agency within the U.S. Department of Energy. By law, EIA's data, analyses, and forecasts are independent of approval by any other officer or employee of the United States Government. The views in this report therefore should not be construed as representing those of the U.S. Department of Energy or other Federal agencies. U.S. Energy Information Administration | Analysis of Impacts of a Clean Energy Standard as requested by Chairman Bingaman i Contacts This report, Analysis of Impacts of a Clean Energy Standard, as requested by Chairman Bingaman, was prepared

260

Standard Elements  

Science Conference Proceedings (OSTI)

Table 1   ASTM standards applicable to element-level testing of composites...Composite Plates Subjected to a Distributed Load Plate flexure D 6484 Open-Hole Compression Strength of Polymer Matrix Composites Open-hole compression strength Z 5370Z Compression After Impact Strength of Fiber-Resin Composites Compression after impact Z 7225Z Mixed Mode I-Mode II...

Note: This page contains sample records for the topic "lamp type standard" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

December 2007 Standards Forum and Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

The Standards Forum & Standards Actions Page 1 December 2007 The Standards Forum & Standards Actions Page 1 December 2007 Continued on next page Technical Standards Program Manager's Note 1 Teaching Standards Development- Inspiring the Next Generation 2 The EPA Radiation Standard for Spent-Fuel Storage in a Geological Repository 3 Expanded Access to Hydrogen Codes and Standards 4 Really Following the Building Code 6 Technical Standards Manager Spotlight 7

262

Appliance Energy Efficiency Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Efficiency Standards Energy Efficiency Standards Appliance Energy Efficiency Standards < Back Program Info State Maryland Program Type Appliance/Equipment Efficiency Standards Provider Maryland Energy Administration '' Note: The federal government has imposed and updated appliance efficiency standards through several legislative acts,* and now has standards in place or under development for 30 classes of products. In general, states which had set standards prior to federal action may enforce their own standards until the federal standards take effect. States that had not set standards prior to federal action must use the federal standards. This summary addresses (1) state appliance standards that will be in place until the federal standards take effect and (2) products for

263

Energy Efficiency Product Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Efficiency Product Standards Efficiency Product Standards Energy Efficiency Product Standards < Back Program Info State New Jersey Program Type Appliance/Equipment Efficiency Standards Provider New Jersey Board of Public Utilities '' Note: The federal government has imposed and updated appliance efficiency standards through several legislative acts,* and now has standards in place or under development for 30 classes of products. In general, states which had set standards prior to federal action may enforce their own standards until the federal standards take effect. States that had not set standards prior to federal action must use the federal standards. This summary addresses (1) state appliance standards that will be in place until the federal standards take effect and (2) products for

264

May 2007 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Technical Technical Standards in Revision 1 DOE Technical Standards Posted in RevCom for TSP 1 DOE Technical Standards in Reaffirmation 1 DOE Technical Standards Change Notices 1 DOE Technical Standards Published 1 Non-Government Standards Actions 2

265

Glass and glass-derivative seals for use in energy-efficient fuel cells and lamps  

DOE Green Energy (OSTI)

For solid oxide fuel cells (SOFC), a series of 18 sealing glasses have been prepared and characterized. From the whole design space, several glasses were ''downselected'' and studied in detail to describe their behaviors in simulated fuel cell environments. One of the glasses was found to outperform all others, including the well-known G18 sealant developed at Pacific Northwest National Laboratory. The new glass composition showed lower bulk electrical conductivity, excellent sealing and wetting behavior when sealing under applied load, and qualitatively superior performance when exposed to wet hydrogen for 800 hours. Traditional melting was used to prepare all of the glasses that were studied in detail. The sol-gel approach was used to synthesize several compositions, but it was found that the glasses crystallized very rapidly during heating, precluding sealing. The glass characterization included measurements of the viscosity and thermal expansion of the glasses, as well as the thermal expansion of the partly crystalline glass ceramics. In addition, the wetting and sintering behavior of all glasses has been measured, as well as the crystallization behavior. The time and temperature at which crystalline phases form from the glasses has been determined for all of the glasses. Each glass ceramic contains at least two crystalline phases, and most of the crystalline phases have been positively identified. The body of fundamental data provides a platform for future developments for high temperature sealants, and the newly-developed glass compositions appear promising for large-scale testing. The second component of the work, focused on seals for higher-temperature discharge lighting, has focused on determining the phase relations in the yttria-alumina-silica system at various silica levels. Functional testing of one of the candidate sealants demonstrated that it performs well in current HID lighting applications. Further testing is required to evaluate its performance in next-generation lamps that operate at higher temperatures, but the baseline phase equilibria and crystallization behavior has been established for additional development. Again, traditional melting and sol-gel synthesis have been employed, and the sol-gel method was successful for preparing new phases that were discovered during the work. Four new phases have been identified and synthesized in pure form, from which full structure solutions were obtained as well as the anisotropic thermal expansion for each phase.

Scott Misture; Arun Varshineya; Matthew Hall; Sylvia DeCarr; Steve Bancheri

2005-07-28T23:59:59.000Z

266

Catalog of Standards  

Science Conference Proceedings (OSTI)

... Catalog of Standards. ... As of May 2013, the number of standards or standards components added to the Catalog of Standards stands at 56. ...

2013-07-31T23:59:59.000Z

267

Improved Photometric Standards and Calibration Procedures ...  

Science Conference Proceedings (OSTI)

... from the external source is incident at 45 while the light from the ... A group of twelve 40 W opal-bulb incandescent lamps, operated at ...

2013-06-17T23:59:59.000Z

268

About non standard Lagrangians in cosmology  

Science Conference Proceedings (OSTI)

A review of non standard Lagrangians present in modern cosmological models will be considered. Well known example of non standard Lagrangian is Dirac-Born-Infeld (DBI) type Lagrangian for tachyon field. Another type of non standard Lagrangian under consideration contains scalar field which describes open p-adic string tachyon and is called p-adic string theory Lagrangian. We will investigate homogenous cases of both DBI and p-adic fields and obtain Lagrangians of the standard type which have the same equations of motions as aforementioned non standard one.

Dimitrijevic, Dragoljub D.; Milosevic, Milan [Department of Physics, Faculty of Science and Mathematics, University of Nis, Visegradska 33, P.O. Box 224, 18000 Nis (Serbia)

2012-08-17T23:59:59.000Z

269

Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Standards Interconnection Standards Interconnection Standards < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Energy Sources Solar Wind Program Info State Maryland Program Type Interconnection Provider Maryland Public Service Commission In April 2007, Maryland enacted legislation ([http://mgaleg.maryland.gov/2007RS/chapters_noln/Ch_119_sb0595E.pdf S.B. 595]) requiring the Maryland Public Service Commission (PSC) to form a small generator interconnection working group to develop interconnection standards and procedures that are "consistent with nationally adopted

270

Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

You are here You are here Home » Interconnection Standards Interconnection Standards < Back Eligibility Agricultural Commercial Residential Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Wind Energy Sources Solar Program Info State Vermont Program Type Interconnection Provider Vermont Public Service Board Vermont has adopted separate interconnection standards for net-metered energy systems that are 150 kW or less, and for all other distributed-generation (DG) systems. '''Interconnection Standards for Net-Metered Systems 150 kW or less''' Vermont requires electric utilities to offer net metering to all customers with photovoltaic (PV) systems, wind-energy systems, fuel cells or

271

Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Standards Interconnection Standards Interconnection Standards < Back Eligibility Commercial Industrial Residential Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Wind Energy Sources Solar Program Info State Texas Program Type Interconnection Provider Public Utility Commission of Texas The Texas Public Utility Regulatory Act (PURA) of 1999 included a provision that "a customer is entitled to have access to on-site distributed generation". As a result, the Public Utility Commission of Texas (PUCT) adopted interconnection standards in 1999. The rules apply to electrical generating facilities (consisting of one or more on-site distributed-generation units) located at a customer's point of delivery,

272

Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Standards Interconnection Standards Interconnection Standards < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Tribal Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Wind Energy Sources Solar Home Weatherization Program Info State South Dakota Program Type Interconnection Provider S.D. Public Utilities Commission South Dakota's interconnection standards for distributed generation, adopted by the state Public Utilities Commission (PUC) in May 2009, apply to customers of investor-owned utilities.* The rules provide for four levels of interconnection for systems up to 10 megawatts (MW) in capacity:

273

Federal Appliance Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Federal Appliance Standards Federal Appliance Standards Federal Appliance Standards < Back Eligibility Industrial Savings Category Heating & Cooling Commercial Heating & Cooling Heating Cooling Appliances & Electronics Heat Pumps Commercial Lighting Lighting Manufacturing Water Heating Program Info Program Type Appliance/Equipment Efficiency Standards Provider U.S. Department of Energy '''''Note: HR 6582 of 2012 made some modifications to the efficiency standards previously adopted for some appliance types. The bill did not adopt new standards for previously unregulated appliances, but made some minor changes to the requirements for walk-in coolers, walk-in freezers, water heaters, self-contained medium temperature commercial refrigerators, central air conditioners, and heat pumps. The bill also included some

274

Federal Information Processing Standards  

Science Conference Proceedings (OSTI)

... Federal Information Processing Standards Publications (FIPS PUBS). ... Replacement Standards for Withdrawn FIPS on Geographic Codes.

2013-07-30T23:59:59.000Z

275

Incandescent Lighting | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

or pear-shaped A-19 lamps Energy-saving or halogen A-19 lamps Reflector or parabolic reflector (PAR) lamps, sometimes called "flood" or "spot" lamps Standard...

276

March 2007 Standards Forum and Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

March 2007 March 2007 Continued on next page TSP Manager's Notes 1 Domestic Programs (American National Standards) Overview 2 Aerospace Industry Advocates Standards Selection Based on Technical Merit, Not Semantics 3 Report Recommends Withdrawal of OMB Risk Assessment Bulletin 4 Technical Standards Manager Spotlight 5 Topical Committee Developments 6 Welcome Aboard the TSMC! 7 Standards Actions 8 DOE Standards Actions 8

277

Energy Efficiency Resource Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Efficiency Resource Standard Efficiency Resource Standard Energy Efficiency Resource Standard < Back Eligibility Investor-Owned Utility Utility Program Info State Rhode Island Program Type Energy Efficiency Resource Standard Provider Rhode Island Public Utilities Commission Rhode Island enacted legislation in 2006 requiring the state Public Utilities Commission (PUC) to establish standards for system reliability, energy efficiency and conservation procurement, including standards for energy supply diversification, distributed generation, demand response, and "prudent and reliable" energy efficiency and energy conservation measures. These standards and guidelines, which were adopted by the PUC in 2008, must be reviewed at least once every three years. Each electric and natural gas

278

Energy Efficiency Portfolio Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Efficiency Portfolio Standard Efficiency Portfolio Standard Energy Efficiency Portfolio Standard < Back Eligibility Investor-Owned Utility Rural Electric Cooperative Savings Category Heating & Cooling Commercial Heating & Cooling Heat Pumps Manufacturing Buying & Making Electricity Solar Water Heating Program Info State Hawaii Program Type Energy Efficiency Resource Standard Provider Hawaii Public Utilities Commission '''''Note: Hawaii's Energy Efficiency Portfolio Standard (EEPS) will not be separate from the state's Renewable Portfolio Standard (RPS) until January 1, 2015. Rules have not yet been established for the EEPS.''''' Hawaii enacted legislation ([http://www.capitol.hawaii.gov/session2009/bills/HB1464_CD1_.htm HB 1464]) in June 2009 that established an Energy Efficiency Portfolio Standard

279

Tungsten Lamps as an Affordable Light Source for Testing of Photovoltaic Cells  

Science Conference Proceedings (OSTI)

An improved Tungsten light source system for photovoltaic cell testing made from low-cost, commercially available materials is presented as an alternative to standard expensive testing equipment. In this work, spectral correction of the Tungsten light ... Keywords: I-V measurement, Light source, Photovoltaic, Testing

Jeydmer Aristizabal; Badr Omrane; Clint Landrock; Sasan Vosoogh-Grayli; Yindar Chuo; Jasbir N. Patel; Bozena Kaminska; Carlo Menon

2011-06-01T23:59:59.000Z

280

The Particle Adventure | Unsolved Mysteries | Beyond the standard...  

NLE Websites -- All DOE Office Websites (Extended Search)

Unsolved Mysteries - Beyond the standard model The Standard Model answers many of the questions about the structure and stability of matter with its six types of quarks, six types...

Note: This page contains sample records for the topic "lamp type standard" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Liquid-Immersed and Medium-Voltage Dry-type Distribution Transformers Energy Conservation Standard Liquid-Immersed and Medium-Voltage Dry-type Distribution Transformers Energy Conservation Standard Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has completed a rulemaking to amend the current energy conservation standards for liquid-immersed, medium voltage dry-type, and low-voltage dry-type distribution transformers. This activity is mandated by the Energy Policy and Conservation Act (EPCA). Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a final rule regarding amended energy efficiency standards for liquid-immersed, medium-voltage dry-type, and low-voltage dry-type distribution transformers. 78 FR 23335 (April 18, 2013). The distribution transformers final rule was the DOE's first "negotiated rulemaking," conducted under the Federal Advisory Committee Act and the Negotiated Rulemaking Act.

282

May 2006 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Standards Actions 1 Standards Actions 1 New Projects and Technical Standards in Revision 1 DOE Technical Standards Posted in RevCom for TSP 1 DOE Technical Standards in Reaffirmation 1 DOE Technical Standards Change Notices 1 DOE Technical Standards Published 1 Non-Government Standards Actions 1 American National Standards Institute (ANSI) 1 American Society of Mechanical Engineers (ASME) 2 ASTM International 2 American Nuclear Society (ANS) 2 National Fire Protection Association (NFPA) 2

283

Climate, Community and Biodiversity Project Design Standards | Open Energy  

Open Energy Info (EERE)

Climate, Community and Biodiversity Project Design Standards Climate, Community and Biodiversity Project Design Standards Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Climate Community and Biodiversity Project Design Standards Agency/Company /Organization: The Climate Community and Biodiversity Alliance Sector: Land Topics: Implementation, Co-benefits assessment, Pathways analysis Resource Type: Guide/manual Website: www.climate-standards.org/standards/pdf/ccb_standards_second_edition_d Climate Community and Biodiversity Project Design Standards Screenshot References: Biodiversity Standards[1] "The CCB Standards have become the most widely used and respected international standard for the multiple-benefits of land-based carbon projects." References ↑ "Biodiversity Standards"

284

Appliance Energy Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Stove, washer, dryer, refrigerator, Energy Star Label Appliance Energy Standards Energy Efficiency Standard The Energy Efficiency Standards Group analyzes technical, economic, and...

285

ISO Standards Documents  

Science Conference Proceedings (OSTI)

ISO/TC 34: Food products and TC 34/SC 17: Management systems for food safety ISO Standards Documents iso3rss ISO Standards Development ISO Standards Development

286

Process for environmentally safe disposal of used fluorescent lamp potted ballast assemblies with component part reclamation and/or recycling  

SciTech Connect

A process is described for the environmentally safe and economical disposal of used fluorescent lamp potted ballast housing assemblies comprising removing from the housing the potted assembly with its embedded electrical component assemblies including a component capacitor containing environmentally hazardous material PCB's; after or before such removing, immersing the potted assembly in a cryogenic bath and freezing the same to reader the potting sufficiently brittle to fragment into small pieces upon being impacted; impacting the potting thoroughly to crush and fragment the same into small pieces and to cleanly remove substantially all traces of the potting from all the electrical components and parts embedded therein and without imparting damage to the components and parts; disconnecting the component containing the environmentally hazardous material; and incinerating only the component containing the environmentally hazardous material, leaving all other components and parts including the housing and potting fragments for salvage, re-use and/or recycling.

Nardella, A.; Norian, B.

1993-07-27T23:59:59.000Z

287

September 2006 Standards Forum/Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

September 2006 September 2006 TSP Manager's Notes 1 TEN YEARS AFTER THE NTTAA: 1996-2006 2 Committee on Nuclear Fuel Cycle Approves Two New Standards 4 Renewable Portfolio Standards Help Wind Industry to Sail 5 Technical Standards Manager Spotlight 5 World Standards Day 2006 in

288

Alternative Fuels Data Center: Fuel Quality Standards  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Fuel Quality Standards Fuel Quality Standards to someone by E-mail Share Alternative Fuels Data Center: Fuel Quality Standards on Facebook Tweet about Alternative Fuels Data Center: Fuel Quality Standards on Twitter Bookmark Alternative Fuels Data Center: Fuel Quality Standards on Google Bookmark Alternative Fuels Data Center: Fuel Quality Standards on Delicious Rank Alternative Fuels Data Center: Fuel Quality Standards on Digg Find More places to share Alternative Fuels Data Center: Fuel Quality Standards on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Fuel Quality Standards The South Dakota Department of Public Safety may promulgate rules establishing: Standards for the maximum volume percentages of ethanol and methanol

289

Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Standards Interconnection Standards Interconnection Standards < Back Eligibility Agricultural Commercial Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Solar Buying & Making Electricity Home Weatherization Water Wind Program Info State Kentucky Program Type Interconnection Provider Kentucky Public Service Commission In April 2008, Kentucky enacted legislation which required the Kentucky Public Service Commission (PSC) to develop interconnection and net metering guidelines for all retail electric suppliers operating in Kentucky (excluding TVA utilities). The Kentucky PSC adopted those guidelines on January 8, 2009 (Order 2008-00169). The PSC's rules set forth a two-tiered approach to simplify the interconnection process:

290

Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Standards Interconnection Standards Interconnection Standards < Back Eligibility Agricultural Commercial Fed. Government General Public/Consumer Industrial Institutional Local Government Nonprofit Residential Schools State Government Tribal Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Water Alternative Fuel Vehicles Hydrogen & Fuel Cells Solar Home Weatherization Wind Program Info State Florida Program Type Interconnection Provider Florida Public Service Commission In March 2008, the Florida Public Service Commission (PSC) adopted interconnection rules for renewable-energy systems up to two megawatts (MW) in capacity. The PSC rules apply only to the state's investor-owned utilities; the rules do not apply to electric cooperatives or municipal

291

Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Standards Interconnection Standards Interconnection Standards < Back Eligibility Commercial Fed. Government Industrial Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Buying & Making Electricity Water Energy Sources Solar Wind Program Info State Maine Program Type Interconnection Provider Maine Public Utilities Commission The Maine Public Utility Commission (PUC) adopted interconnection procedures in January 2010. These rules apply to all transmission and distribution utilities operating in the state and apply to all distribution generation (not just renewables). Maine's interconnection procedures, based in part on the Interstate Renewable Energy Council Inc. 2006 Model Interconnection Procedures,* identify four different tiers with

292

Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Standards Interconnection Standards Interconnection Standards < Back Eligibility Commercial Fed. Government Industrial Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Wind Energy Sources Solar Program Info State Hawaii Program Type Interconnection Provider Hawaii Public Utilities Commission Hawaii has established simplified interconnection rules for small renewables and separate rules for all other distributed generation (DG). For inverter-based systems up to 10 kilowatts (kW) in capacity (and inverter-based DG under 250 kW on islands other than Kauai), there is a simple application process for interconnection. Systems must use inverters

293

Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Standards Interconnection Standards Interconnection Standards < Back Eligibility Commercial Fed. Government Industrial Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Wind Energy Sources Solar Program Info State Minnesota Program Type Interconnection Provider Minnesota Public Utilities Commission Minnesota's net-metering law, enacted in 1983, applies to all investor-owned utilities, municipal utilities and rural electric cooperatives. Qualifying facilities of less than 1,000 kilowatts (kW) are eligible for net metering. However, uniform interconnection regulations were not implemented when net metering was established.

294

Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Standards Interconnection Standards Interconnection Standards < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Wind Energy Sources Solar Program Info State Indiana Program Type Interconnection Provider Indiana Utility Regulatory Commission In November 2005, the Indiana Utility Regulatory Commission (IURC) approved rules governing the interconnection of distributed generation (DG). Indiana's interconnection rules require the state's investor-owned utilities to provide three levels of interconnection to customer-generators.

295

Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Standards Interconnection Standards Interconnection Standards < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Biofuels Alternative Fuel Vehicles Commercial Heating & Cooling Manufacturing Buying & Making Electricity Hydrogen & Fuel Cells Water Energy Sources Solar Home Weatherization Wind Program Info State New Hampshire Program Type Interconnection Provider New Hampshire Public Utilities Commission New Hampshire requires all utilities selling electricity in the state to offer net metering to customers who own or operate systems up to one megawatt (1 MW) in capacity that generate electricity using solar, wind, geothermal, hydro, tidal, wave, biomass, landfill gas, bio-oil or

296

Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Standards Interconnection Standards Interconnection Standards < Back Eligibility Commercial Fed. Government Industrial Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Wind Energy Sources Solar Program Info State Connecticut Program Type Interconnection Provider Public Utilities Regulatory Authority In December 2007, the Connecticut Department of Public Utility Control (DPUC) now called the Public Utilities Regulatory Authority (PURA) approved new interconnection guidelines for distributed energy systems up to 20 megawatts (MW) in capacity. Connecticut's interconnection guidelines apply to the state's two investor-owned utilities -- Connecticut Light and Power

297

Exploration of illumination concepts for underground coal mines. Appendix E. Electronic ballast for the Lucalox high pressure sodium lamp. Final report  

SciTech Connect

The report documents the results of an investigation to develop solid-state ballasts for Lucalox high-pressure sodium lamps. The ballasts were to be used in the modified and new portable and machine-mounted lighting systems designed by the Crouse-Hinds Co., per tasks I through IV of Contract No. H022065.

1976-07-20T23:59:59.000Z

298

April 2006 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1 1 New Projects and Technical Standards in Revision 1 DOE Technical Standards Posted in RevCom for TSP 1 DOE Technical Standards in Reaffirmation 1 DOE Technical Standards Change Notices 1 DOE Technical Standards Published 1 Non-Government Standards Actions 1 American National Standards Institute (ANSI) 1 American Society of Mechanical Engineers (ASME) 2 ASTM International 2 American Nuclear Society (ANS) 2 National Fire Protection Association (NFPA) 2 DOE Technical Standards Program Document Status

299

Standard-Related Links  

Science Conference Proceedings (OSTI)

... Standard-Related Links. ... Association for Clinical Chemistry ACS - American Chemical Society ANSI - American National Standards Institute AOAC ...

2013-06-28T23:59:59.000Z

300

Standard Reference Materials  

Science Conference Proceedings (OSTI)

... Inn, KGW, Liggett, WS, and Hutchinson, JMR (1984), "The National Bureau of Standards Rocky Flats Soil Standard Reference Material," Nuclear ...

Note: This page contains sample records for the topic "lamp type standard" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Federal Technical Standards Workshop  

Science Conference Proceedings (OSTI)

... missions, authorities, priorities, and budget resources.". ... of developing a strategic standards management plan. ... Director of NIST's Office of Standards ...

2010-10-05T23:59:59.000Z

302

LAMP-TR-108 NOVEMBER 2003 UMIACS-TR-2003-109  

E-Print Network (OSTI)

the right sorts of pages - Enter the Altavista search terms - Enter the words that identify sentences structure. Click Proceed to Search. Then enter the description "The ADJer the NP the ADJer the NP" and click to the LSE's My Collections screen. Paste or type the query you copied into the LSE's Altavista Search Terms

Gruner, Daniel S.

303

Property:RenewableFuelStandard/Total | Open Energy Information  

Open Energy Info (EERE)

Total Total Jump to: navigation, search This is a property of type Number. Pages using the property "RenewableFuelStandard/Total" Showing 15 pages using this property. R Renewable Fuel Standard Schedule + 13.95 + Renewable Fuel Standard Schedule + 26 + Renewable Fuel Standard Schedule + 15.2 + Renewable Fuel Standard Schedule + 28 + Renewable Fuel Standard Schedule + 16.55 + Renewable Fuel Standard Schedule + 30 + Renewable Fuel Standard Schedule + 18.15 + Renewable Fuel Standard Schedule + 9 + Renewable Fuel Standard Schedule + 33 + Renewable Fuel Standard Schedule + 20.5 + Renewable Fuel Standard Schedule + 11.1 + Renewable Fuel Standard Schedule + 36 + Renewable Fuel Standard Schedule + 22.25 + Renewable Fuel Standard Schedule + 12.95 + Renewable Fuel Standard Schedule + 24 +

304

October 2005 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Standards Actions 1 Standards Actions 1 New Projects and DOE Technical Standards in Revision 1 DOE Technical Standards Posted in RevCom for TSP 1 DOE Technical Standards in Reaffirmation 1 DOE Technical Standards Change Notices 1 DOE Technical Standards Recently Published 1 Non-Government Standards Actions 1 American National Standards Institute (ANSI) 1 American Society of Mechanical Engineers (ASME) 2 ASTM International 2 American Nuclear Society (ANS) 2 American Nuclear Society (ANS) 2 National Fire Protection Association (NFPA) 2 DOE Technical Standards Program

305

Standard Solar | Open Energy Information  

Open Energy Info (EERE)

Standard Solar Standard Solar Jump to: navigation, search Logo: Standard Solar Name Standard Solar Address 202 Perry Parkway Place Gaithersburg, Maryland Zip 20877 Sector Solar Product Solar Integration Specialists - Residential and Commercial Year founded 2004 Number of employees 51-200 Phone number 888-474-3843 Website http://www.StandardSolar.com Coordinates 39.1406595°, -77.2095182° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":39.1406595,"lon":-77.2095182,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

306

Alternative Fuels Data Center: Renewable Fuel Standard  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Renewable Fuel Renewable Fuel Standard to someone by E-mail Share Alternative Fuels Data Center: Renewable Fuel Standard on Facebook Tweet about Alternative Fuels Data Center: Renewable Fuel Standard on Twitter Bookmark Alternative Fuels Data Center: Renewable Fuel Standard on Google Bookmark Alternative Fuels Data Center: Renewable Fuel Standard on Delicious Rank Alternative Fuels Data Center: Renewable Fuel Standard on Digg Find More places to share Alternative Fuels Data Center: Renewable Fuel Standard on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Renewable Fuel Standard RFS Volumes by Year Enlarge illustration The Renewable Fuel Standard (RFS) is a federal program that requires transportation fuel sold in the U.S. to contain a minimum volume of

307

DOE Directives, Regulations, and Standards Portal - Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Globe Image Department of Energy (DOE) Technical Standards Program Home Search Approved Standards Recently Approved RevCom Logo RevCom for TSP Drafts for Review Registered Projects...

308

April 2007 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

New Projects and Technical Standards in Revision 1 DOE Technical Standards Posted in RevCom for TSP 1 DOE Technical Standards in Reaffirmation 1 DOE Technical Standards Change Notices 1 Technical Standards Published 2 Non-Government Standards Actions 2 American National Standards Institute (ANSI) 2 American Society of Mechanical Engineers (ASME) 2 ASTM International 2 American Nuclear Society (ANS) 2 National Fire Protection Association (NFPA) 2 DOE Technical

309

November 2005 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DOE Technical DOE Technical Standards in Revision 1 DOE Technical Standards Posted in RevCom for TSP 1 DOE Technical Standards in Reaffirmation 1 DOE Technical Standards Change Notices 1 DOE Technical Standards Revisions 1 Non-Government Standards Actions 1 American National Standards Institute (ANSI) 1 American Society of Mechanical Engineers (ASME) 2 ASTM International 2 American Nuclear Society (ANS) 2 National Fire Protection Association

310

NIST Global Standards Information Global Standards News  

Science Conference Proceedings (OSTI)

... 2010 The National Institute of Standards and Technology (NIST) has advised the Federal Energy Regulatory Commission ... DGI), Austin, Texas, were ...

311

NIST Global Standards Information Standards Education  

Science Conference Proceedings (OSTI)

... Grants supporting the development of new learning resources and course modules integrating standards into the formal curriculum in Business and ...

312

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Residential Water Heaters Residential Water Heaters Sign up for e-mail updates on regulations for this and other products Manufacturers have been required to comply with the Department of Energy (DOE) energy conservation standards for residential water heaters since 1990. Residential water heaters are products that utilize oil, gas, or electricity to heat potable water for use upon demand for activities such as washing dishes or clothes, or bathing. Residential water heaters include storage type units that store heated water in an insulated tank and instantaneous type units that heat water on demand. The standard mandatory in 1990 will save approximately 3.2 quads of energy and result in approximately $34.8 billion in energy bill savings for products shipped from 1990-2019. The standard will avoid about 180 million metric tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of about 35.3 million automobiles.

313

September 2005 Standards Forum and Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Page September 2005 Page September 2005 TSP Manager's Notes 1 The Halo Effect: American National Standards and the rest 2 Standards Development for Report- ing of Declarable Substances 5 Technical Standards Manager Spotlight 8 DOE Revises "Integration of Environment, Safety, and Health

314

December 2006 Standards Forum and Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

December 2006 December 2006 TSP Manager's Notes 1 Meeting In The Middle 2 Plain Talk for a New Generation 3 Licensing New Nuclear Power Plants 4 ANSI Government Affairs Overview 5 Technical Standards Manager Spotlight 7 Topical Committee Developments 8 Welcome Aboard the TSMC! 8 Standards Actions 9 DOE Standards Actions 9

315

Property:RenewableFuelStandard/RenewableBiofuel | Open Energy Information  

Open Energy Info (EERE)

RenewableBiofuel RenewableBiofuel Jump to: navigation, search This is a property of type Number. Pages using the property "RenewableFuelStandard/RenewableBiofuel" Showing 15 pages using this property. R Renewable Fuel Standard Schedule + 12.6 + Renewable Fuel Standard Schedule + 15 + Renewable Fuel Standard Schedule + 13.2 + Renewable Fuel Standard Schedule + 15 + Renewable Fuel Standard Schedule + 13.8 + Renewable Fuel Standard Schedule + 15 + Renewable Fuel Standard Schedule + 14.4 + Renewable Fuel Standard Schedule + 9 + Renewable Fuel Standard Schedule + 15 + Renewable Fuel Standard Schedule + 15 + Renewable Fuel Standard Schedule + 10.5 + Renewable Fuel Standard Schedule + 15 + Renewable Fuel Standard Schedule + 15 + Renewable Fuel Standard Schedule + 12 +

316

Property:RenewableFuelStandard/UndifferentiatedAdvancedBiofuel | Open  

Open Energy Info (EERE)

UndifferentiatedAdvancedBiofuel UndifferentiatedAdvancedBiofuel Jump to: navigation, search This is a property of type Number. Pages using the property "RenewableFuelStandard/UndifferentiatedAdvancedBiofuel" Showing 14 pages using this property. R Renewable Fuel Standard Schedule + 0.5 + Renewable Fuel Standard Schedule + 4.5 + Renewable Fuel Standard Schedule + 1.75 + Renewable Fuel Standard Schedule + 4.5 + Renewable Fuel Standard Schedule + 2 + Renewable Fuel Standard Schedule + 4.5 + Renewable Fuel Standard Schedule + 2.5 + Renewable Fuel Standard Schedule + 0.1 + Renewable Fuel Standard Schedule + 5 + Renewable Fuel Standard Schedule + 3 + Renewable Fuel Standard Schedule + 0.2 + Renewable Fuel Standard Schedule + 3.5 + Renewable Fuel Standard Schedule + 0.3 + Renewable Fuel Standard Schedule + 4 +

317

Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Standards Interconnection Standards Interconnection Standards < Back Eligibility Commercial Fed. Government Industrial Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Buying & Making Electricity Water Solar Wind Program Info State Virginia Program Type Interconnection Provider Virginia State Corporation Commission Virginia has two interconnection standards: one for net-metered systems and one for systems that are not net-metered. '''Interconnection for Net-Metered Systems''' Customer-generators that net meter must comply with the interconnection rules within the regulations governing net metering (20 VAC 5-315-40). These rules apply to residential customers generating up to 10 kW* and commercial systems of up to 500 kW (or greater if the utility's net

318

Standards Actions, July 2002  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Standards Program Document Status 07-01-2002 Activity Summary In Conversion - 4 In Preparation - 46 Out for Comment - 14 Published this Month - 2 5-year Review Status Revision in Progress - 11 Reaffirmation in Progress - 12 Cancellation Pending - 7 Cancellation in Progress - 1 No Current Action - 19 Inside this issue: DOE Technical Standards Projects Initiated 1 DOE Technical Standards Re- cently Sent for Coordination 1 DOE Technical Standards Re- cently Published 1 American National Standards Institute 2 American Society for Testing and Materials International 4 Visit the Technical Standards Program Web Site at http://tis.eh.doe.gov/techstds/. Standards Actions- July 2002 Standards Actions DOE Technical Standards Projects Initiated

319

Standards Actions, May 2001  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

30-2001 30-2001 Activity Summary In Conversion - 4 In Preparation - 39 Out for Comment - 19 Published this Month - 0 5-year Review Status Revision in Progress - 4 Reaffirmation in Progress - 23 Cancellation Pending - 9 Cancellation in Progress - 18 No Current Action - 12 Inside this issue: DOE Technical Standards Projects Initiated 1 DOE Technical Standards Proposed for Reaffirmation 1 Proposed Cancellation of DOE Technical Standards 2 Published DOE Technical Standards 3 American National Standards Institute 3 American National Standards 6 American Society for Testing and Materials 6 Visit the Technical Standards Program Web Site at http://tis.eh.doe.gov/techstds/. May 2001 Standards Actions DOE Technical Standards Projects Initiated

320

Emergency Episode Standards (Ohio) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Emergency Episode Standards (Ohio) Emergency Episode Standards (Ohio) Emergency Episode Standards (Ohio) < Back Eligibility Agricultural Construction Fuel Distributor Industrial Investor-Owned Utility Local Government Municipal/Public Utility Rural Electric Cooperative State/Provincial Govt Transportation Tribal Government Utility Program Info State Ohio Program Type Environmental Regulations Provider Ohio Environmental Protection Agency This chapter of the law authorizing the Ohio Environmental Protection Agency gives a detailed description of the excessive buildup of air contaminants during air pollution episodes that leads to an emergency. The law sets the standards for limits on different types of air pollution, the criteria for an emergency situation, and the foundation for emergency action programs.

Note: This page contains sample records for the topic "lamp type standard" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

DOE Technical Standards Program Standards Actions Newsletter  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

* * New DOE Standard, Communicating Waste Characterization and DOT Hazard Classification Requirements * Workshops and Events * The Annual Energy Facility Contractors Group Safety Analysis Workshop * 2012 Chemical Safety and Life Cycle Management Workshop * Nuclear Safety- Related Standards Activity INSIDE THIS ISSUE April 2012 Standards Actions Technical Standards Program Newsletter www.hss.energy.gov/nuclearsafety/ns/techstds/ New DOE Standard, Communicating Waste Characterization and DOT Hazard Classification Requirements The Department of Energy (DOE) Office of Environmental Management (EM) has a challenging mission to solve many problems posed by the legacy of the Cold War, including the transportation of unprecedented amounts of contaminated waste,

322

May 2005 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Notices 1 DOE Technical Standards Revisions 1 DOE Technical Standards Projects Initiated 1 Non-Government Standards Actions 1 American National Standards Institute (ANSI) 1 American Society of Mechanical Engineers (ASME) 2 ASTM International 2 American Nuclear Society (ANS) 2 National Fire Protection Association (NFPA) 2 DOE Technical Standards Program Document Status 04-27-2005 Activity Summary In Conversion - 4 In Preparation - 25

323

Generativity and dynamic opacity for abstract types  

Science Conference Proceedings (OSTI)

The standard formalism for explaining abstract types is existential quantification. While it provides a sufficient model for type abstraction in entirely statically typed languages, it proves to be too weak for languages enriched with forms of dynamic ... Keywords: abstract types, dynamic typing, encapsulation, existential types, generativity, opacity

Andreas Rossberg

2003-08-01T23:59:59.000Z

324

NETL: Publication Standards Manual  

NLE Websites -- All DOE Office Websites (Extended Search)

Standards Manual Publications Publication Standards Manual Click on the logo to access the NETL Publication Standards Manual 2003 APEX Logo Click on the logo or on the link below...

325

Thick Buildings [Standards  

E-Print Network (OSTI)

STANDARDS The idea of tracts of windowless indoor space hassider U.S. practices and standards? building with four sidesAs these codes and standards change future generations may

Coffin, Christie Johnson

1995-01-01T23:59:59.000Z

326

Questioning Copyright in Standards  

E-Print Network (OSTI)

adoption and use of privately drafted industry standards).arising from abuses of standard-setting processes are well-at 7. Compliance with standards has often implicated patent

Samuelson, Pam

2006-01-01T23:59:59.000Z

327

February 2007 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DOE Technical Standards Posted in RevCom for TSP 1 DOE Technical Standards in Reaffirmation 1 DOE Technical Standards Change Notices 1 DOE Technical Standards Published1 Non-Government Standards Actions 2 American National Standards Institute (ANSI) 2 American Society of Mechanical Engineers (ASME) 2 ASTM International 2 American Nuclear Society (ANS) 2 National Fire Protection Association (NFPA) 2 Publication Staff Roster 2

328

Renewables Portfolio Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Renewables Portfolio Standard Renewables Portfolio Standard Renewables Portfolio Standard < Back Eligibility Investor-Owned Utility Municipal Utility Retail Supplier Savings Category Other Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Solar Wind Program Info State Connecticut Program Type Renewables Portfolio Standard Provider Connecticut Public Utilities Regulatory Authority Established in 1998 and subsequently revised several times, Connecticut's renewables portfolio standard (RPS) requires each electric supplier and each electric distribution company wholesale supplier to obtain at least 23% of its retail load by using renewable energy by January 1, 2020. The RPS also requires each electric supplier and each electric distribution

329

Energy Efficiency Resource Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Efficiency Resource Standards Energy Efficiency Resource Standards Energy Efficiency Resource Standards < Back Eligibility Investor-Owned Utility Municipal Utility Rural Electric Cooperative Savings Category Other Program Info State Delaware Program Type Energy Efficiency Resource Standard Provider Delaware Department of Natural Resources and Environmental Control In July 2009 the Delaware legislature enacted legislation creating energy savings targets for Delaware's investor-owned, municipal, and cooperative electric utilities, as well the state's natural gas distribution companies. These targets are hereafter referred to collectively as the Delaware Energy Efficiency Resource Standard or EERS. The law requires affected electric utilities to establish programs which save the equivalent

330

Columbia - Renewables Portfolio Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Columbia - Renewables Portfolio Standard Columbia - Renewables Portfolio Standard Columbia - Renewables Portfolio Standard < Back Eligibility Municipal Utility Savings Category Bioenergy Buying & Making Electricity Water Solar Heating & Cooling Commercial Heating & Cooling Heating Water Heating Wind Program Info State Missouri Program Type Renewables Portfolio Standard Provider Columbia Water and Light In November 2004, voters in Columbia, Missouri approved a proposal to adopt a local renewables portfolio standard (RPS).* The initiative requires the city's municipal utility, Columbia Water and Light, to generate or purchase electricity generated from eligible renewable-energy resources at the following levels: * 2% by December 31, 2007 * 5% by December 31, 2012 * 10% by December 31, 2017 * 15% by December 31, 2022

331

Austin - Renewables Portfolio Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Austin - Renewables Portfolio Standard Austin - Renewables Portfolio Standard Austin - Renewables Portfolio Standard < Back Eligibility Municipal Utility Savings Category Bioenergy Buying & Making Electricity Water Solar Wind Program Info State Texas Program Type Renewables Portfolio Standard Provider Austin Energy The City of Austin, Texas, has been an early adopter of the Renewable Portfolio Standard (RPS) regulatory incentive. Using long term planning strategies, the City has set annual benchmarks for the percentage of renewable energy it uses annually. In February 2007, the Austin City Council approved Resolution 20070215-023, adopting the mayor's [http://www.austintexas.gov/department/austin-climate-protection-program Climate Protection Plan]. The Resolution increased Austin's renewable

332

Renewables Portfolio Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

You are here You are here Home » Renewables Portfolio Standard Renewables Portfolio Standard < Back Eligibility Investor-Owned Utility Municipal Utility Rural Electric Cooperative Savings Category Bioenergy Water Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Solar Wind Program Info State Minnesota Program Type Renewables Portfolio Standard Provider Minnesota Department of Commerce Minnesota enacted legislation in 2007 that created a renewable portfolio standard (RPS) for Xcel Energy, created a separate RPS for other electric utilities,* and modified the state's existing non-mandated renewable-energy objective. In 2013, further legislation (H.F 729) was enacted to create a 1.5% solar standard for public utilities, a distributed generation

333

Alternative Energy Portfolio Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Alternative Energy Portfolio Standard Alternative Energy Portfolio Standard Alternative Energy Portfolio Standard < Back Eligibility Investor-Owned Utility Retail Supplier Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Cooling Commercial Heating & Cooling Appliances & Electronics Other Sealing Your Home Ventilation Heat Pumps Commercial Lighting Lighting Windows, Doors, & Skylights Bioenergy Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Energy Sources Solar Heating Water Heating Wind Program Info State Pennsylvania Program Type Renewables Portfolio Standard Provider Pennsylvania Public Utility Commission Pennsylvania's Alternative Energy Portfolio Standard (AEPS), created by S.B. 1030 on November 30, 2004, requires each electric distribution company

334

Renewables Portfolio Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Renewables Portfolio Standard Renewables Portfolio Standard Renewables Portfolio Standard < Back Eligibility Investor-Owned Utility Retail Supplier Rural Electric Cooperative Savings Category Bioenergy Biofuels Alternative Fuel Vehicles Commercial Heating & Cooling Manufacturing Buying & Making Electricity Hydrogen & Fuel Cells Water Wind Solar Home Weatherization Heating & Cooling Heating Water Heating Program Info State New Hampshire Program Type Renewables Portfolio Standard Provider New Hampshire Public Utilities Commission New Hampshire's renewable portfolio standard (RPS), established in May 2007, requires the state's electricity providers -- with the exception of municipal utilities -- to acquire by 2025 renewable energy certificates (RECs) equivalent to 24.8% of retail electricity sold to end-use customers.

335

Appliances and Commercial Equipment Standards: Guidance  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Office Office HOME ABOUT ENERGY EFFICIENT TECHNOLOGIES RESIDENTIAL BUILDINGS COMMERCIAL BUILDINGS APPLIANCE & EQUIPMENT STANDARDS BUILDING ENERGY CODES EERE » Building Technologies Office » Appliances & Equipment Standards About Standards & Test Procedures Implementation, Certification & Enforcement Rulemakings & Notices Further Guidance ENERGY STAR® Guidance and Frequently Asked Questions This webpage is designed to provide guidance and answer Frequently Asked Questions (FAQs) on the U.S. Department of Energy's appliance standards program. Guidance types span all covered products and covered equipment and cover such topics as: definitions, scope of coverage, conservation standards, test procedures, certification, Compliance and Certification Management System (CCMS), and enforcement. This website offers users an

336

Renewable Portfolio Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Renewable Portfolio Standard Renewable Portfolio Standard Renewable Portfolio Standard < Back Eligibility Investor-Owned Utility Municipal Utility Rural Electric Cooperative Utility Savings Category Bioenergy Biofuels Alternative Fuel Vehicles Commercial Heating & Cooling Manufacturing Buying & Making Electricity Hydrogen & Fuel Cells Water Solar Home Weatherization Heating & Cooling Water Heating Wind Program Info State Wisconsin Program Type Renewables Portfolio Standard Provider Public Service Commission of Wisconsin In 1998 Wisconsin enacted Act 204, requiring regulated utilities in eastern Wisconsin to install to an aggregate total of 50 MW of new renewable-based electric capacity by December 31, 2000. In October 1999 Wisconsin enacted Act 9, becoming the first state to enact a renewable portfolio standard

337

Alternative Fuels Data Center: Biodiesel Blend Standards  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Biodiesel Blend Biodiesel Blend Standards to someone by E-mail Share Alternative Fuels Data Center: Biodiesel Blend Standards on Facebook Tweet about Alternative Fuels Data Center: Biodiesel Blend Standards on Twitter Bookmark Alternative Fuels Data Center: Biodiesel Blend Standards on Google Bookmark Alternative Fuels Data Center: Biodiesel Blend Standards on Delicious Rank Alternative Fuels Data Center: Biodiesel Blend Standards on Digg Find More places to share Alternative Fuels Data Center: Biodiesel Blend Standards on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Biodiesel Blend Standards Biodiesel blends are considered compliant with Texas Low Emissions Diesel Fuel (TxLED) regulations if the diesel fuel is compliant with TxLED

338

Alternative Fuels Data Center: Renewable Fuel Standard  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Renewable Fuel Renewable Fuel Standard to someone by E-mail Share Alternative Fuels Data Center: Renewable Fuel Standard on Facebook Tweet about Alternative Fuels Data Center: Renewable Fuel Standard on Twitter Bookmark Alternative Fuels Data Center: Renewable Fuel Standard on Google Bookmark Alternative Fuels Data Center: Renewable Fuel Standard on Delicious Rank Alternative Fuels Data Center: Renewable Fuel Standard on Digg Find More places to share Alternative Fuels Data Center: Renewable Fuel Standard on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Renewable Fuel Standard At least 2% of all diesel fuel sold in Washington must be biodiesel or renewable diesel. This requirement will increase to 5% 180 days after the

339

Alternative Fuels Data Center: Renewable Fuel Standard  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Renewable Fuel Renewable Fuel Standard to someone by E-mail Share Alternative Fuels Data Center: Renewable Fuel Standard on Facebook Tweet about Alternative Fuels Data Center: Renewable Fuel Standard on Twitter Bookmark Alternative Fuels Data Center: Renewable Fuel Standard on Google Bookmark Alternative Fuels Data Center: Renewable Fuel Standard on Delicious Rank Alternative Fuels Data Center: Renewable Fuel Standard on Digg Find More places to share Alternative Fuels Data Center: Renewable Fuel Standard on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Renewable Fuel Standard Within six months following the point at which monthly production of denatured ethanol produced in Louisiana equals or exceeds a minimum annualized production volume of 50 million gallons, at least 2% of the

340

Demonstration of LED Retrofit Lamps at an Exhibit of 19th Century Photography at the Getty Museum  

SciTech Connect

This document is a report of observations and results obtained from a lighting demonstration project conducted under the U.S. Department of Energy (DOE) GATEWAY Demonstration Program. The program supports demonstrations of high-performance solid-state lighting (SSL) products in order to develop empirical data and experience with in-the-field applications of this advanced lighting technology. The DOE GATEWAY Demonstration Program focuses on providing a source of independent, third-party data for use in decision-making by lighting users and professionals; this data should be considered in combination with other information relevant to the particular site and application under examination. Each GATEWAY Demonstration compares SSL products against the incumbent technologies used in that location. Depending on available information and circumstances, the SSL product may also be compared to alternate lighting technologies. Though products demonstrated in the GATEWAY program may have been prescreened for performance, DOE does not endorse any commercial product or in any way guarantee that users will achieve the same results through use of these products. This report reviews the installation and use of LED PAR38 lamps to light a collection of toned albument photographic prints at the J. Paul Getty Museum in Malibu, California. Research results provided by the Getty Conservation Institute are incorporated and discussed.

Miller, Naomi J.; Druzik, Jim

2012-03-02T23:59:59.000Z

Note: This page contains sample records for the topic "lamp type standard" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

April 2011 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3009 3009 Revision * DOE Standard 1066 Revision * New DOE Standards Projects * Incidents of Security Concern Technical Standard * Explosives Safety * Operations Assessment Field Handbook * Reporting of Radioactive Sealed Sources Program * Occurrence Reporting Causal Analysis Guide * Nuclear Safety-Related Standards Activity INSIDE THIS ISSUE April 2011 Standards Actions Technical Standards Program Newsletter www.hss.energy.gov/nuclearsafety/ns/techstds/ DOE Standard 3009 Revision The Office of Nuclear Safety Policy and Assistance (HS-21), within the Office of Health, Safety and Security (HSS), conducted workshops in January and March to support a major revision of Department of Energy (DOE) Standard 3009, Preparation Guide for U.S. Department of Energy Nonreactor

342

Automated Voltage Standard Ready  

Science Conference Proceedings (OSTI)

... We wanted a standard that was ... as envisioned, then within our lifetimes there will no longer be a need for voltage transfer standards that have to be ...

2013-04-08T23:59:59.000Z

343

complex dimensional standards  

Science Conference Proceedings (OSTI)

... Mailing Address: National Institute of Standards and Technology 100 Bureau Drive ... of CMS Software: NIST-generated data sets, standard level (per ...

2013-06-27T23:59:59.000Z

344

Surrogate protein particle standards  

Science Conference Proceedings (OSTI)

... The large particles may be useful as a standard for the counting of ... drugs require visual inspection, at present there are no standards available for ...

2013-09-10T23:59:59.000Z

345

Appliance Efficiency Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Appliance Efficiency Standards Part 1 of 2 In the National Energy Policy Conservation Act (1978), Congress required DOE to set energy-efficiency standards for 13 residential...

346

Cryptographic Standards Statement  

Science Conference Proceedings (OSTI)

... standard. We will continue in our mission to work with the cryptographic community to create the strongest possible encryption standards for the US ...

2013-09-10T23:59:59.000Z

347

Cytomegalovirus Standard Reference Material  

Science Conference Proceedings (OSTI)

... and reagent manufacturers in production of their own calibrants and standards. ... control materials which would be traceable to a NIST standard. ...

2013-03-15T23:59:59.000Z

348

Sustainability Standards Portal  

Science Conference Proceedings (OSTI)

... links to the original standard/ directive developer website ... for harmonizing standards and directives (future work ... for information only; it does not imply ...

349

Battery Standard Scenario  

Science Conference Proceedings (OSTI)

Scenario: Fast Tracking a Battery Standard. ... with developing a new standard specifying quality controls for the development of batteries used in ...

350

DOE CALiPER Program, Report 20.1 Subjective Evaluation of Beam Quality, Shadow Quality, and Color Quality for LED PAR38 Lamps  

Science Conference Proceedings (OSTI)

This report focuses on human-evaluated characteristics, including beam quality, shadow quality, and color quality. Using a questionnaire that included rank ordering, opinions on 27 of the Report 20 PAR38 lamps were gathered during a demonstration event for members of the local Illuminating Engineering Society (IES) chapter. This was not a rigorous scientific experiment, and the data should not be extrapolated beyond the scope of the demonstration. The results suggest that many of the LED products compared favorably to halogen PAR38 benchmarks in all attributes considered. LED lamps using a single-emitter design were generally preferred for their beam quality and shadow quality, and the IES members ranking of color quality did not always match the rank according to the color rendering index (CRI).

Royer, Michael P.; Poplawski, Michael E.; Miller, Naomi J.

2013-10-01T23:59:59.000Z

351

Atomic gas temperature in a nonequilibrium high-intensity discharge lamp determined from the red wing of the resonance mercury line 254 nm  

Science Conference Proceedings (OSTI)

For developing low-wattage high intensity discharge (HID) lamps, a better understanding of the relatively unexplored nonequilibrium phenomena is essential. This needs interpretation of diagnostic results by methods free from equilibrium assumptions. In this paper, the atomic temperature is determined from the simulation of a quasistatic broadened resonance line by distinguishing between atomic temperature and excitation temperature in the equation of radiative transfer. The proposed method is applied to the red wing of the resonance mercury line 254 nm emitted from a HID lamp working on ac. The experimental results show severe deviation from local thermodynamic equilibrium. More than one thousand degrees difference was obtained between atomic and electron temperatures at the maximum current phase.

Drakakis, E. [Technological Educational Institute, Department of Electrical Engineering, 71004 Heraklion (Greece); Karabourniotis, D. [Institute of Plasma Physics, Department of Physics, University of Crete, 71003 Heraklion (Greece)

2012-09-01T23:59:59.000Z

352

Assessment of Electrical, Efficiency, and Photometric Performance of Advanced Lighting Sources: Dimmable Advanced Lighting Technolog ies -- Electronic (Hot and Cold Cathode) Compact Fluorescent Lamps and Ballasts  

Science Conference Proceedings (OSTI)

This EPRI Technical Update (EPRI report 1018477) is one of four in a series that addresses basic dimming performance of advanced lighting sourceselectronic (hot and cold cathode) compact fluorescent lamps and ballasts Chapter 1 discusses basic lighting control, the importance of considering power quality in lighting control, lighting control methods and parameters, and the advantages and future of lighting control. Chapter 2 addresses in more depth dimming methods used in advanced lighting sources and co...

2008-12-19T23:59:59.000Z

353

May 2009 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

May 2009 May 2009 U.S. Department of Energy Technical Standards Program (http://www.hss.energy.gov/nuclearsafety/ns/techstds/) Standards Actions 1.0 DOE STANDARDS ACTIONS The Department of Energy (DOE) Technical Standards Program (TSP) publishes Standards Actions on a monthly basis to provide DOE headquarters and field elements with current information on DOE and select non-government standards activities. The complete list of all DOE Technical Standards projects and their status is available on the TSP web page at: http://www.hss.energy.gov/nuclearsafety/ns/techstds/. To access these standards, go to our web page, click on "DOE Technical Standards," then choose Projects, Approved Standards, Recently Approved Standards, or Drafts for Review, as

354

February 2009 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

February 2009 February 2009 U.S. Department of Energy Technical Standards Program (http://www.hss.energy.gov/nuclearsafety/ns/techstds/) Standards Actions 1.0 DOE STANDARDS ACTIONS The Department of Energy (DOE) Technical Standards Program (TSP) publishes Standards Actions on a monthly basis to provide DOE headquarters and field elements with current information on DOE and select non-government standards activities. The complete list of all DOE Technical Standards projects and their status is available on the TSP web page at: http://www.hss.energy.gov/nuclearsafety/ns/techstds/. To access these standards, go to our web page, click on "DOE Technical Standards," then choose Projects, Approved Standards, Recently Approved Standards, or Drafts for Review, as

355

July 2009 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

July 2009 U.S. Department of Energy Technical Standards Program (http://www.hss.energy.gov/nuclearsafety/ns/techstds/) Standards Actions 1.0 DOE STANDARDS ACTIONS The Department of Energy (DOE) Technical Standards Program (TSP) publishes Standards Actions on a monthly basis to provide DOE headquarters and field elements with current information on DOE and select non-government standards activities. The complete list of all DOE Technical Standards projects and their status is available on the TSP web page at: http://www.hss.energy.gov/nuclearsafety/ns/techstds/. To access these standards, go to our web page, click on "DOE Technical Standards," then choose Projects, Approved Standards, Recently Approved Standards, or Drafts for Review, as

356

May 2010 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

May 2010 U.S. Department of Energy Technical Standards Program (http://www.hss.energy.gov/nuclearsafety/ns/techstds/) Standards Actions 1.0 DOE STANDARDS ACTIONS The Department of Energy (DOE) Technical Standards Program (TSP) publishes Standards Actions on a monthly basis to provide DOE headquarters and field elements with current information on DOE and select non-government standards activities. The complete list of all DOE Technical Standards projects and their status is available on the TSP web page at: http://www.hss.energy.gov/nuclearsafety/ns/techstds/. To access these standards, go to our web page, click on "DOE Technical Standards," then choose Projects, Approved Standards, Recently Approved Standards, or Drafts for Review, as

357

An Ontology For Standards  

E-Print Network (OSTI)

The paper continues the exploration of standards that the authors initiated in [1] and continued in [2] and [3]. It provides an ontology for standards---a specification of the things and relationships relevant to the topic of standards. The ontology is presented using the ISO standard graphical language, EXPRESS-G. It uses concepts from mathematical logic to clarify the content, meaning, and use of standards. Characteristics and elements of standards that are independent of any particular usage of the standard are defined. The subject matter of standardization is classified and a taxo nomy is presented. Instances of earliest use of each part of the taxonomy are described. The means of establis hing standards is discussed, together with the question of voluntary versus mandatory compliance. The paper closes with a set of conclusions regarding management process standards. The paper concentrates on those aspects of standards of importance to systems engineering, and includes numerous illustrative exa mples.

J. R. Velman; E. R. Widmann

2000-01-01T23:59:59.000Z

358

Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

You are here You are here Home » Interconnection Standards Interconnection Standards < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Water Solar Wind Program Info State Iowa Program Type Interconnection Provider Iowa Utilities Board Different rules govern the interconnection of distributed generation facilities in Iowa, depending on whether or not the interconnection is with a utility whose rates are regulated by the Iowa Utilities Board (IUB). Rate regulated utilities include only the state's two investor-owned utilities -- MidAmerican Energy and Interstate Power and Light (IPL) -- and Linn

359

NIST Global Standards Information Global Standards News  

Science Conference Proceedings (OSTI)

... (EPRI) to help it develop an interim "roadmap" for determining the architecture and initial key standards for an electric power "Smart Grid". ...

360

Standards and Certification  

Science Conference Proceedings (OSTI)

... Standards and Certification. Voluntary Voting System Guidelines (VVSG). The Help America Vote Act instructed the Election ...

2013-09-17T23:59:59.000Z

Note: This page contains sample records for the topic "lamp type standard" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

FMOC Standards Program  

NLE Websites -- All DOE Office Websites (Extended Search)

spacer Facilities Management and Operations Center (FMOC) Standards Program (removed) Sandia Home...

362

Standards Development Organization Overview  

Science Conference Proceedings (OSTI)

... Standards Organizations NFPA (National Fire Protection Association) ... Fire News Annual directory NFPA Buyer's Guide ... Headquarters ...

2010-04-28T23:59:59.000Z

363

December 2005 Standards Forum  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Page December 2005 Page December 2005 TSP Manager's Notes 1 Overview of the U.S. Standardization System 2 A Call for Greater Collaboration 5 Technical Standards Manager Spotlight 6 Topical Committee Developments 7 Welcome Aboard the TSMC! 8 DOE Standards Actions 9 Non-Government Standards

364

March 2006 Standards Forum and Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1 March 2006 1 March 2006 TSP Manager's Notes 1 New ISO Policy Provides International Solutions to Market Needs 2 Plain Talk for a New Generation 5 The Use of Voluntary Consensus Standards within the Department of Energy 7 Two Change Notices for DOE Standard 1104 8

365

February 2013 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3 3 Standards Actions Technical Standards Program Newsletter U . S . D E PA R T M E N T O F O ffi ce O f nuclear SaFety ENERGY inSide thiS iSSue * Featured DOE Technical Standards Activities * DOE Technical Standards Cost- Savings and Access Improvement Initiative * Domestic and International Nuclear Energy Voluntary Consensus Standards Needs * Nuclear Safety- Related Standards Activity Featured dOe technical StandardS activitieS DOE Technical Standards Cost-Savings and Access Improvement Initiative By Helen Todosow, Brookhaven National Laboratory The Department of Energy (DOE) Technical Standards Managers (TSM) are actively exploring ways to save the government and tax payers' money while at the same time significantly improving efficiencies in access and use of voluntary consensus

366

Appliance/Equipment Efficiency Standards | Open Energy Information  

Open Energy Info (EERE)

Appliance/Equipment Efficiency Standards Appliance/Equipment Efficiency Standards Jump to: navigation, search Many states have established minimum efficiency standards for certain appliances and equipment. In these states, the retail sale of appliances and equipment that do not meet the established standards is prohibited. The federal government has also established efficiency standards for certain appliances and equipment. When both the federal government and a state have adopted efficiency standards for the same type of appliance or equipment, the federal standard overrides the state standard even if the state standard is stricter. [1] Appliance/Equipment Efficiency Standards Incentives CSV (rows 1 - 14) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active Appliance Efficiency Regulations (California) Appliance/Equipment Efficiency Standards California Yes

367

NETL Publication Standards Manual  

NLE Websites -- All DOE Office Websites (Extended Search)

Standards NETL Publication Standards Manual Publication Standards Manual Click on topic below to view Click "Contents" in the bookmarks panel at the left of your screen to return to this page Introduction * Overview * About This Manual - Point of Contact - Download Files - Permission - Signage - Special Applications Publication Standards * Design Elements * Fact Sheets * Font (Typeface) * Full-Size Brochures * Logo * Presentations * Report Covers NETL Publication Standards Manual Overview For over 60 years, we have been at the forefront

368

Appliance and Equipment Efficiency Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Efficiency Standards Efficiency Standards Appliance and Equipment Efficiency Standards < Back Program Info State Arizona Program Type Appliance/Equipment Efficiency Standards Provider Arizona Department of Commerce '' Note: The federal government has imposed and updated appliance efficiency standards through several legislative acts,* and now has standards in place or under development for 30 classes of products. In general, states which had set standards prior to federal action may enforce their own standards until the federal standards take effect. States that had not set standards prior to federal action must use the federal standards. This summary addresses (1) state appliance standards that will be in place until the federal standards take effect and (2) products for which the federal government is not currently developing an efficiency

369

Appliance and Equipment Energy Efficiency Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Appliance and Equipment Energy Efficiency Standards Appliance and Equipment Energy Efficiency Standards Appliance and Equipment Energy Efficiency Standards < Back Program Info State Oregon Program Type Appliance/Equipment Efficiency Standards Provider Oregon Department of Energy '' Note: The federal government has imposed and updated appliance efficiency standards through several legislative acts,* and now has standards in place or under development for 30 classes of products. In general, states which had set standards prior to federal action may enforce their own standards until the federal standards take effect. States that had not set standards prior to federal action must use the federal standards. This summary addresses (1) state appliance standards that will be in place until the federal standards take effect and (2) products for

370

Energy Efficiency Standards for Appliances | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Efficiency Standards for Appliances Efficiency Standards for Appliances Energy Efficiency Standards for Appliances < Back Program Info State Connecticut Program Type Appliance/Equipment Efficiency Standards Provider Department of Energy and Environmental Protection '' Note: The federal government has imposed and updated appliance efficiency standards through several legislative acts,* and now has standards in place or under development for 30 classes of products. In general, states which had set standards prior to federal action may enforce their own standards until the federal standards take effect. States that had not set standards prior to federal action must use the federal standards. This summary addresses (1) state appliance standards that will be in place until the federal standards take effect and (2) products for

371

Appliance and Equipment Energy Efficiency Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Appliance and Equipment Energy Efficiency Standards Appliance and Equipment Energy Efficiency Standards Appliance and Equipment Energy Efficiency Standards < Back Program Info State District of Columbia Program Type Appliance/Equipment Efficiency Standards Provider Washington State Department of Commerce '' Note: The federal government has imposed and updated appliance efficiency standards through several legislative acts,* and now has standards in place or under development for 30 classes of products. In general, states which had set standards prior to federal action may enforce their own standards until the federal standards take effect. States that had not set standards prior to federal action must use the federal standards. This summary addresses (1) state appliance standards that will be in place until the federal standards take effect and (2) products for

372

Energy Efficiency Standards for Appliances | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Efficiency Standards for Appliances Energy Efficiency Standards for Appliances Energy Efficiency Standards for Appliances < Back Program Info State District of Columbia Program Type Appliance/Equipment Efficiency Standards Provider District Department of the Environment '' Note: The federal government has imposed and updated appliance efficiency standards through several legislative acts,* and now has standards in place or under development for 30 classes of products. In general, states which had set standards prior to federal action may enforce their own standards until the federal standards take effect. States that had not set standards prior to federal action must use the federal standards. This summary addresses (1) state appliance standards that will be in place until the federal standards take effect and (2) products for

373

Appliance and Equipment Energy Efficiency Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Efficiency Standards Energy Efficiency Standards Appliance and Equipment Energy Efficiency Standards < Back Program Info State New York Program Type Appliance/Equipment Efficiency Standards Provider New York State Energy Research and Development Authority '' Note: The federal government has imposed and updated appliance efficiency standards through several legislative acts,* and now has standards in place or under development for 30 classes of products. In general, states which had set standards prior to federal action may enforce their own standards until the federal standards take effect. States that had not set standards prior to federal action must use the federal standards. This summary addresses (1) state appliance standards that will be in place until the federal standards take effect and (2) products for

374

Buildings Energy Data Book: 7.6 Efficiency Standards for Lighting  

Buildings Energy Data Book (EERE)

4 4 Lighting Standards for General Service Incandescent Lamps Prescribed by EISA 2007 General Service Incandescent Effective Date Maximum Wattage Rated Lumen Range Minimum Life Modified Spectrum General Service Incandescent Effective Date Maximum Wattage Rated Lumen Range Minimum Life By 2020, the minimum efficacy for general service incandescent will be 45 lm/W unless the Secretary of Energy has implemented another standard which saves as much or more energy than a 45 lm/W standard. Source(s): U. S. Government, Energy Independence and Security Act of 2007, January 2007, Section 321. 2014 43 563-787 1000 hrs. 2015 29 232-563 1000 hrs. 2012 72 1,118-1,950 1000 hrs. 2013 53 788-1,117 1000 hrs. 2014 43 750-1,049 1000 hrs. 2015 29 310-749 1000 hrs. 2012 72 1,490-2,600 1000 hrs. 2013 53 1,050-1,498

375

Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Standards Interconnection Standards Interconnection Standards < Back Eligibility Commercial Fed. Government Industrial Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Wind Energy Sources Solar Program Info State New Mexico Program Type Interconnection Provider New Mexico Public Regulation Commission Interconnection in New Mexico is governed by New Mexico Public Regulation Commission (PRC) Rule 568 and Rule 569. These rules, adopted in July 2008, revised and clarified the state's existing rules. Rule 569 applies to all qualifying facilities (QFs) under PURPA, which generally includes all renewable-energy systems and combined-heat-and-power (CHP) systems up to 80

376

Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Standards Interconnection Standards Interconnection Standards < Back Eligibility Commercial Fed. Government Industrial Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Wind Energy Sources Solar Program Info State Ohio Program Type Interconnection Provider Ohio Public Utilities Commission '''''Note: In July 2012, the Public Utilities Commission of Ohio (PUCO) opened a docket ([http://dis.puc.state.oh.us/CaseRecord.aspx?CaseNo=12-2051&x=0&y=0 Case 12-0251-EL-ORD]) to review the net metering and interconnection rules for investor-owned utilities. Details will be posted as more information is available.'''''

377

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Residential Clothes Dryers Residential Clothes Dryers Sign up for e-mail updates on regulations for this and other products Manufacturers have been required to comply with the Department of Energy's (DOE) energy conservation standards for residential clothes dryers since 1988. Residential clothes dryers use a tumble-type drum with forced air circulation to dry clothes. They are commonly used in homes, but are also used in some dormitory, apartment, or small business settings. The current standard will save approximately 0.9 quads of energy and result in approximately $9.6 billion in energy bill savings for products shipped from 1994-2023. The standard will avoid about 50.3 million metric tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of 9.9 million automobiles.

378

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Unit Heaters Unit Heaters Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of unit heaters since 2008. Unit heaters are self-contained fan-type heaters designed to be installed within the heated space, such as rooms, garages, or factory floors. Unit heaters do not include warm air furnaces. The current standard will save approximately 1.3 quads of energy and result in approximately $13.4 billion in energy bill savings for products shipped from 2008-2032. The standard will avoid about 66.8 million metric tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of about 13.1 million automobiles. Recent Updates | Standards | Test Procedures | Waiver, Exception, and Exemption Information | Statutory Authority | Historical Information | Contact Information

379

Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Standards Interconnection Standards Interconnection Standards < Back Eligibility Commercial Industrial Residential Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Wind Energy Sources Solar Program Info State California Program Type Interconnection Provider California Public Utilities Commission '''''Note: The California Public Utilities Commission (CPUC) approved a [http://docs.cpuc.ca.gov/EFILE/MOTION/162852.PDF proposed settlement] in September 2012, enacting the first fundamental redesign of Rule 21 since 2000. The complete revised Rule 21 Tariff, as described at a high level below, can be found beginning on page 136 of CPUC Decision 12-09-018. The individual tariffs adopted by the utilities can be found on the CPUC web

380

CONVERSION OF DOE TECHNICAL STANDARDS TO NON-GOVERNMENT STANDARDS...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

CONVERSION OF DOE TECHNICAL STANDARDS TO NON-GOVERNMENT STANDARDS CONVERSION OF DOE TECHNICAL STANDARDS TO NON-GOVERNMENT STANDARDS Purpose This procedure provides guidance on the...

Note: This page contains sample records for the topic "lamp type standard" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

The Standards Actions, October 1996  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Actions Actions October 1996 Documents Recently Published The following DOE documents have recently been published: * DOE-SPEC-3018-96, Flooded-Type Lead-Acid Storage Batter- ies, August 1996. * DOE-SPEC-3019-96, Valve- Regulated Type Lead-Acid Storage Batteries, August 1996. * DOE-TSL-1-96, Department of Energy Standards Index, August 1996. * DOE-TSL-4-96, Directory of DOE and Contractor Personnel Involved in Non-Government Standards Activities, August 1996. DOE employees and DOE contractors may obtain copies from the DOE Office of Scientific and Technical Information (OSTI), P.O. Box 62, Oak Ridge, Tennes- see 37831; telephone 423-576-8401 or FAX 423-576-2865. Subcontractors and the general public may obtain copies from the U.S. Department of Commerce, Technology Administration,

382

Evaluation of Energy-Efficiency Standards for Room Air Conditioners...  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy-Efficiency Standards for Room Air Conditioners in the US Title Evaluation of Energy-Efficiency Standards for Room Air Conditioners in the US Publication Type Journal Article...

383

August 2001 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7-31-2001 7-31-2001 Activity Summary In Conversion-4 In Preparation-43 Out for Comment-17 Published this Month-0 5-year Review Status Revision in Progress-6 Reaffirmation in Progress-23 Cancellation Pending-4 Cancellation in Progress-12 Proposed for Cancellation-13 No Current Action-11 Inside this issue: DOE Technical Standards Project Initiated 1 DOE Technical Standards Recently Sent for Coordination 1 DOE Technical Standard Recently Reaffirmed 1 DOE Technical Standards Recently Published 2 American National Standards Institute 2 American National Standards 4 American Society for Testing and Materials 5 Visit the Technical Standards Program Web Site at http://tis.eh.doe.gov/techstds/. Standards Actions- August 2001 Standards

384

November 2000 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

November 2000 November 2000 Standards Technical Standards Program Document Status Visit the Technical Standards Program Web Site: http://tis.eh.doe.gov/techstds/ DOE Technical Standards Projects Initiated If you have any questions or are interested in participating in the development of these standards, please contact the representatives listed below. Complete listings of all DOE Technical Standards projects and their status are given on the Technical Standards Pro- gram (TSP) Web Site referenced at the bottom of this page. To access these lists from the home page, click on “DOE Technical Standards,” then click on “Projects” in the left- hand frame to show the links to the project lists. The following DOE Technical Standards projects were recently initiated: • Radiological Control Programs for Special Tritium Compounds, Project Number OCSH-

385

Standards Actions, February 2004  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1 1 DOE Technical Standards Recently Sent for Coordination 1 DOE Technical Standards Recently Published 1 Non-Government Standards 2 American National Standards Institute (ANSI) 2 American Society of Mechanical Engineers (ASME) 5 American Society for Testing and Materials (ASTM) 6 American Nuclear Society (ANS) 11 National Fire Protection Association (NFPA) 12 DOE Technical Standards Program Document Status 01-23-2004 Activity Summary In Conversion - 4 In Preparation - 36 Out for Comment - 23 Published in January - 3 5-year Review Status Revision in Progress - 13 Reaffirmation in Progress - 26 Cancellation Pending - 1 Cancellation in Progress - 3 No Current Action - 0 Inside This Visit the Technical Standards Program

386

July 2005 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DOE Technical Standards in Reaffirmation 1 DOE Technical Standards Change Notices 1 DOE Technical Standards Recently Published 1 Non-Government Standards Actions 2 American National Standards Institute (ANSI) 2 American Society of Mechanical Engineers (ASME) 2 ASTM International 2 American Nuclear Society (ANS) 2 National Fire Protection Association (NFPA) 2 DOE Technical Standards Program Document Status 06-28-2005 Activity Summary In Conversion - 4 In Preparation - 21 Out for Comment - 10 Published in June - 2 5-year Review Status Proposed for Revision-6 Revision in Progress-3

387

Candidate Biomarkers for Type 2 Diabetes - Available ...  

The current gold standard for diagnosing pre-diabetes and type 2 diabetes is the oral glucose tolerance test (OGTT), which is used to determine ...

388

Nucleic Acid Standards - Standard Ref. Frame  

NLE Websites -- All DOE Office Websites (Extended Search)

Standard Reference Standard Reference Standard Reference Frame Supplemental Information Ideal Geometries X-PLOR Parameters Valence Geometries RNA Ontology Consortium mmCIF Resources PDBML Resources A Standard Reference Frame for the Description of Nucleic Acid Base-pair Geometry A common point of reference is needed to describe the three-dimensional arrangements of bases and base pairs in nucleic acid structures. [1]. For example, parts of a structure, which appear "normal" according to one computational scheme, may be highly unusual according to another and vice versa. It is thus difficult to carry out comprehensive comparisons of nucleic acid structures and to pinpoint unique conformational features in individual structures. In order to resolve these issues, a group of

389

Renewable Portfolio Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Portfolio Standard Portfolio Standard Renewable Portfolio Standard < Back Eligibility Investor-Owned Utility Retail Supplier Savings Category Bioenergy Biofuels Alternative Fuel Vehicles Water Buying & Making Electricity Solar Wind Program Info State Illinois Program Type Renewables Portfolio Standard In August 2007, Illinois enacted legislation (Public Act 095-0481) that created the Illinois Power Agency (IPA). The agency's purpose is to develop electricity procurement plans for investor-owned electric utilities (EUs) supplying over 100,000 Illinois customers to ensure "adequate, reliable, affordable, efficient, and environmentally sustainable electric service at the lowest total cost." The only EUs that meet these criteria and are therefore subject to the IPA procurement process are Commonwealth

390

Energy Efficiency Resource Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Efficiency Resource Standard Efficiency Resource Standard Energy Efficiency Resource Standard < Back Eligibility Investor-Owned Utility Utility Savings Category Other Bioenergy Buying & Making Electricity Solar Heating & Cooling Water Heating Wind Program Info State Wisconsin Program Type Energy Efficiency Resource Standard Provider Public Service Commission of Wisconsin In March 2006, Wisconsin enacted Act 141 (2005), which requires the commission to revise goals, priorities, and measurable targets for energy efficiency programs every 4 years. An order issued by the Public Service Commission (PSC) in November 2010 set annual percentage targets for electricity and natural gas reductions for the first 4-year planning period (2011-2014). Funding is provided by ratepayers to the utilities' statewide

391

Alternative Energy Portfolio Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Alternative Energy Portfolio Standard Alternative Energy Portfolio Standard Alternative Energy Portfolio Standard < Back Eligibility Investor-Owned Utility Retail Supplier Savings Category Commercial Heating & Cooling Manufacturing Buying & Making Electricity Program Info State Massachusetts Program Type Other Policy Provider Massachusetts Department of Energy Resources In July 2008, Governor Patrick signed a major energy reform bill, the [http://www.malegislature.gov/Laws/SessionLaws/Acts/2008/Chapter169 Green Communities Act (S.B. 2768)]. As part of that legislation, Massachusetts created the Alternative Energy Portfolio Standard (APS), which requires meeting 5% of the state's electric load with "alternative energy" by 2020 according to the following schedule: * 1.00% by 2009

392

Electric Efficiency Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Electric Efficiency Standard Electric Efficiency Standard Electric Efficiency Standard < Back Eligibility Investor-Owned Utility Retail Supplier Savings Category Heating & Cooling Commercial Heating & Cooling Heating Cooling Other Appliances & Electronics Heat Pumps Commercial Lighting Lighting Home Weatherization Insulation Design & Remodeling Program Info State Indiana Program Type Energy Efficiency Resource Standard Provider Indiana Utility Regulatory Commission In December 2009, the Indiana Utility Regulatory Commission's (IURC) ordered utilities to establish demand-side management (DSM) electric savings goals leading to 2.0% reduction of electricity sales by the year 2019. Utilities under IURC jurisdiction must file three-year DSM plans, beginning in July of 2010, which indicate progress and plans for reaching

393

Oklahoma Pollutant Discharge Elimination System (OPDES) Standards  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Oklahoma Pollutant Discharge Elimination System (OPDES) Standards Oklahoma Pollutant Discharge Elimination System (OPDES) Standards (Oklahoma) Oklahoma Pollutant Discharge Elimination System (OPDES) Standards (Oklahoma) < Back Eligibility Agricultural Commercial Construction Fed. Government Fuel Distributor Industrial Installer/Contractor Investor-Owned Utility Local Government Municipal/Public Utility Nonprofit Retail Supplier Rural Electric Cooperative State/Provincial Govt Systems Integrator Tribal Government Utility Program Info State Oklahoma Program Type Environmental Regulations Provider Oklahoma Department of Environmental Quality This program of the Water Quality Division of the Department of Environmental Quality sets the point source, biosolids (sewage sludge), and stormwater permitting standards for discharges to the waters of the State

394

Water Quality Standards (Ohio) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Standards (Ohio) Standards (Ohio) Water Quality Standards (Ohio) < Back Eligibility Utility Fed. Government Commercial Agricultural Investor-Owned Utility State/Provincial Govt Industrial Construction Municipal/Public Utility Local Government Installer/Contractor Rural Electric Cooperative Tribal Government Retail Supplier Institutional Fuel Distributor Nonprofit Transportation Savings Category Water Buying & Making Electricity Home Weatherization Program Info State Ohio Program Type Environmental Regulations Provider Ohio Environmental Protection Agency This chapter of the law that establishes the Ohio Environmental Protection Agency outlines the minimum water quality requirements for all surface waters of the state. Water quality standards contain two distinct elements: designated uses; and

395

Evergreen Sustainable Development Standard for Affordable Housing |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Evergreen Sustainable Development Standard for Affordable Housing Evergreen Sustainable Development Standard for Affordable Housing Evergreen Sustainable Development Standard for Affordable Housing < Back Eligibility Low-Income Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Commercial Weatherization Sealing Your Home Cooling Appliances & Electronics Construction Design & Remodeling Ventilation Heat Pumps Commercial Lighting Lighting Water Heating Solar Buying & Making Electricity Program Info State District of Columbia Program Type Green Building Incentive Provider Housing Trust Fund The Washington State Department of Commerce created the Evergreen Sustainable Development Standard, a set of green building criteria that is required for any affordable housing project applying for state funds

396

Renewable Energy Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Standard Standard Renewable Energy Standard < Back Eligibility Investor-Owned Utility Municipal Utility Rural Electric Cooperative Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Solar Wind Program Info State Colorado Program Type Renewables Portfolio Standard Provider Colorado Public Utilities Commission '''''Note: The law described on this page was amended by Senate Bill 252 of 2013. Among other changes, the bill doubled the renewable energy requirement for cooperative utilities of a certain size, allowed for additional technologies to qualify, created a distributed generation carve-out for cooperative utilities, and made a new requirement for generation and transmission cooperatives. After signing the legislation,

397

Renewable Portfolio Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

You are here You are here Home » Renewable Portfolio Standard Renewable Portfolio Standard < Back Eligibility Investor-Owned Utility Rural Electric Cooperative Savings Category Heating & Cooling Commercial Heating & Cooling Heat Pumps Bioenergy Biofuels Alternative Fuel Vehicles Manufacturing Buying & Making Electricity Hydrogen & Fuel Cells Water Solar Heating Water Heating Wind Program Info State Hawaii Program Type Renewables Portfolio Standard Provider Hawaii Public Utilities Commission Under Hawaii's Renewable Portfolio Standard (RPS), each electric utility company that sells electricity for consumption in Hawaii must establish the following percentages of "renewable electrical energy" sales: * 10% of its net electricity sales by December 31, 2010;

398

Appliance and Equipment Efficiency Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Appliance and Equipment Efficiency Standards Appliance and Equipment Efficiency Standards Appliance and Equipment Efficiency Standards < Back Savings Category Appliances & Electronics Commercial Lighting Lighting Program Info State Rhode Island Program Type Appliance/Equipment Efficiency Standards Provider Rhode Island Office of Energy Resources '' Note: The federal government has imposed and updated appliance efficiency standards through several legislative acts,* and now has standards in place or under development for 30 classes of products. In general, states which had set standards prior to federal action may enforce their own standards until the federal standards take effect. States that had not set standards prior to federal action must use the federal standards. This summary addresses (1) state appliance standards that will

399

February 2005 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Technical Technical Standards Program Document Status 1-18-2005 Activity Summary In Conversion - 4 In Preparation - 25 Out for Comment - 10 Published in January - 3 5-year Review Status Proposed for Revision-6 Revision in Progress-4 Proposed for Reaffirmation-3 Reaffirmation in Progress-21 Cancellation Pending-16 Cancellation in Progress-0 Visit the Technical Standards Program Web Site at http://tis.eh.doe.gov/techstds/ February 2005 Standards Actions 1.0 DOE Standards Actions The complete list of all DOE Technical Standards projects and their status is available on the Technical Standards Program (TSP) web page at http://tis.eh.doe.gov/techstds/. To access these standards, go to our web page, click on "DOE Technical Standards," then choose Projects,

400

July 2006 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DOE Technical DOE Technical Standards Program Document Status 06-28-2006 Activity Summary In Conversion - 4 In Preparation - 23 Out for Comment - 14 Published in June - 0 5-year Review Status Proposed for Revision-5 Revision in Progress-6 Proposed for Reaffirmation-1 Reaffirmation in Progress-21 Cancellation Pending-9 Cancellation in Progress-0 Inside This Issue Visit the Technical Standards Program Web Site at http://www.eh.doe.gov/ techstds/ July 2006 Standards Actions 1.0 DOE Standards Actions The complete list of all DOE Technical Standards projects and their status is available on the Technical Standards Program (TSP) web page at http://www.eh.doe.gov/techstds/. To access these standards, go to our web page, click on "DOE Technical Standards," then choose Projects,

Note: This page contains sample records for the topic "lamp type standard" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

January 2012 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

* DOE Conduct of Operations Standards Revisions * New DOE Standards Projects * DOE Handbook of Operational Safety and Analysis Techniques * Nuclear Safety- Related Standards Activity INSIDE THIS ISSUE January 2012 Standards Actions Technical Standards Program Newsletter www.hss.energy.gov/nuclearsafety/ns/techstds/ DOE Conduct of Operations Standards Revisions In the early 1990s, the Department of Energy (DOE) developed 17 technical standards to support DOE Order 5480.19, Conduct of Operations Requirements for DOE Facilities. The standards (STDs), listed below, provided examples, good practices, and expanded explanations of the topics in each chapter of the Order. In June 2010, the Order was revised and issued as DOE Order 422.1, Conduct of Operations. The

402

Standard Seawater Comparisons Updated  

Science Conference Proceedings (OSTI)

Salinity adjustments that may reconcile differences in results from different expeditions are presented. These corrections are based upon batch-to-batch differences in Standard Seawater (SSW) after comparison with KC1-derived standards.

Arnold W. Mantyla

1987-04-01T23:59:59.000Z

403

Standard Model Summary  

NLE Websites -- All DOE Office Websites (Extended Search)

resumen del Modelo Standard Avanzar Volver Principal ESTOY PERDIDO Lo que hace que el Modelo Standard sea tan amplio es el hecho que todas las partculas observadas pueden ser...

404

AOCS: supporting international standards  

Science Conference Proceedings (OSTI)

Trade standards improve efficiency of production and ease international commerce. They can also affect profitability. AOCS: supporting international standards inform Magazine algae algal AOCS biomass business chemistry cottonseed date detergents f

405

Standards Actions, July 2001  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

6-27-2001 6-27-2001 Activity Summary In Conversion - 4 In Preparation - 42 Out for Comment - 15 Published this Month - 1 5-year Review Status Revision in Progress - 4 Reaffirmation in Progress - 2 Supersedure in Progress - 6 Cancellation Pending - 8 Cancellation in Progress - 2 No Current Action - 35 Inside this issue: DOE Technical Standards Project Initiated 1 DOE Technical Standard Recently Sent for Coordination 1 DOE Technical Standard Recently Published 1 American National Standards Institute 2 American National Standards 3 American Society for Testing and Materials 4 Visit the Technical Standards Program Web Site at http://tis.eh.doe.gov/techstds/. July 2001 Standards Actions DOE Technical Standards Projects Initiated

406

Standards Actions - April 2002  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3-28-2002 3-28-2002 Activity Summary In Conversion - 4 In Preparation - 44 Out for Comment - 13 Published this Month - 2 5-year Review Status Revision in Progress - 4 Reaffirmation in Progress - 2 Supersedure in Progress - 6 Cancellation Pending - 8 Cancellation in Progress - 2 No Current Action - 35 Inside this issue: DOE Technical Standards Project Canceled 1 DOE Technical Standard Recently Sent for Coordination 1 DOE Technical Standards Re- cently Published 2 American National Standards Institute 2 American Society for Testing and Materials International 4 Visit the Technical Standards Program Web Site at http://tis.eh.doe.gov/techstds/. Standards Actions- April 2002 Standards Actions DOE Technical Standards Project Canceled

407

November 2006 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Notices 1 DOE Technical Standards Published 1 Non-Government Standards Actions 2 American National Standards Institute (ANSI) 2 American Society of Mechanical Engineers (ASME) 2 ASTM International 2 American Nuclear Society (ANS) 2 National Fire Protection Association (NFPA) 2 Publication Staff Roster 2 DOE Technical Standards Program Document Status 10-25-2006 Activity Summary In Conversion - 4 In Preparation - 23 Out for Comment - 16 Published in September - 0 5-year Review Status Proposed for Revision-5 Revision in Progress-6

408

Standard Reference Data  

Science Conference Proceedings (OSTI)

... The National Standard Reference Data System (NSRDS-NBS) provides access to the quantitative data of physical sciences, critically evaluated ...

2013-09-19T23:59:59.000Z

409

Law Enforcement Standards Office  

Science Conference Proceedings (OSTI)

... Talking Police OLES supports the SAFECOM and COPS programs through standards leadership. News. Expanded CSI Guide Now Available. ...

2013-09-20T23:59:59.000Z

410

Related Metrology Standards  

Science Conference Proceedings (OSTI)

... Dynamic measurement -- Proving systems for volumetric meters -- Part 2: Pipe provers. ... Manual of Petroleum Measurement Standards. Contact. ...

2011-10-03T23:59:59.000Z

411

Appendix: Industry Standards  

Science Conference Proceedings (OSTI)

Table 13   Commonly used standards and references for downstream (refining) materials...Practices for the Control

412

Appliance Efficiency Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Appliance Efficiency Standards and Price Discrimination C. Anna Spurlock Energy Analysis & Environmental Impact Department Environmental Energy Technologies Division Lawrence...

413

Energy Efficiency and Green Building Standards for State Buildings...  

Open Energy Info (EERE)

State Buildings Incentive Type Energy Standards for Public Buildings Applicable Sector State Government Eligible Technologies Comprehensive MeasuresWhole Building, Biomass,...

414

Green Building and Energy Reduction Standards for State Agencies...  

Open Energy Info (EERE)

for State Agencies Incentive Type Energy Standards for Public Buildings Applicable Sector State Government Eligible Technologies Comprehensive MeasuresWhole Building, Biomass,...

415

Fuel economy standards have affected vehicle efficiency - Today in ...  

U.S. Energy Information Administration (EIA)

This new footprint standard required that all vehicle manufacturers improve their fuel economy at a similar rate, regardless of the types and sizes of vehicles sold.

416

Phosphors for LED lamps  

DOE Patents (OSTI)

A phosphor, a phosphor blend including the phosphor, a phosphor prepared by a process, and a lighting apparatus including the phosphor blend are disclosed. The phosphor has the formula (Ca.sub.1-p-qCe.sub.pK.sub.q).sub.xSc.sub.y(Si.sub.1-rGa.sub.r).sub.zO.su- b.12+.delta. or derived from a process followed using disclosed amounts of reactants. In the formula, (0

Murphy, James Edward; Manepalli, Satya Kishore; Kumar, Prasanth Nammalwar

2013-08-13T23:59:59.000Z

417

Radiological Control Technician: Standardized technician Qualification Standard  

Science Conference Proceedings (OSTI)

The Qualification Standard states and defines the knowledge and skill requirements necessary for successful completion of the Radiological Control Technician Training Program. The standard is divided into three phases: Phase I concerns RCT Academic training. There are 13 lessons associated with the core academics program and 19 lessons associated with the site academics program. The staff member should sign the appropriate blocks upon successful completion of the examination for that lesson or group of lessons. In addition, facility specific lesson plans may be added to meet the knowledge requirements in the Job Performance Measures (JPM) of the practical program. Phase II concerns RCT core/site practical (JPMs) training. There are thirteen generic tasks associated with the core practical program. Both the trainer/evaluator and student should sign the appropriate block upon successful completion of the JPM. In addition, facility specific tasks may be added or generic tasks deleted based on the results of the facility job evaluation. Phase III concerns the oral examination board successful completion of the oral examination board is documented by the signature of the chairperson of the board. Upon completion of all of the standardized technician qualification requirements, final qualification is verified by the student and the manager of the Radiological Control Department and acknowledged by signatures on the qualification standard. The completed Qualification Standard shall be maintained as an official training record.

Not Available

1992-10-01T23:59:59.000Z

418

April 2004 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1 1 DOE Technical Standards recently sent for coordination 1 DOE Technical Standards Recently Published 1 Non-Government Standards 2 American National Standards Institute (ANSI) 2 American Society of Mechanical Engineers (ASME) 7 American Society for Testing and Materials (ASTM) 8 American Nuclear Society (ANS) 12 National Fire Protection Association 12 ry DOE Technical Standards Program Document Status 03-26-2004 Activity Summary In Conversion - 4 In Preparation - 37 Out for Comment - 21 Published in March - 2 5-Year Review Status Revision in Progress - 13 Reaffirmation inProgress - 26 Cancellation Pending - 1

419

Provincial Operating Standards (Ontario) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Provincial Operating Standards (Ontario) Provincial Operating Standards (Ontario) Provincial Operating Standards (Ontario) < Back Eligibility Construction Developer Fuel Distributor Industrial Installer/Contractor Investor-Owned Utility Municipal/Public Utility Utility Program Info Start Date 1/24/2002 State Ontario Program Type Environmental Regulations Fees Safety and Operational Guidelines Siting and Permitting Provider Ontario Ministry of Natural Resources The Provincial Operating Standards set the technical minimum requirements for cover wells and works regulated under the Oil, Gas and Salt Resources Act. These standards are the minimum requirements for the design, installation, operation, abandonment and safety of wells and works, but are not intended for use as a design handbook. In addition, the Standards outline the permitting process for injection

420

Renewables Portfolio Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Renewables Portfolio Standard Renewables Portfolio Standard Renewables Portfolio Standard < Back Eligibility Investor-Owned Utility Rural Electric Cooperative Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Solar Wind Program Info State New Mexico Program Type Renewables Portfolio Standard Provider New Mexico Public Regulation Commission '''''Note: The New Mexico Public Regulation Commission (PRC) [http://www.nmprc.state.nm.us/administrative-services/docs/press-releases... passed an order] in December 2012, making some significant changes to the state's Renewables Portfolio Standard. Notably, the order increased the carve-out for wind from 20% to 30% of the overall standard. It also increased the reasonable cost threshold for investor-owned utilities such

Note: This page contains sample records for the topic "lamp type standard" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Renewables Portfolio Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Renewables Portfolio Standard Renewables Portfolio Standard Renewables Portfolio Standard < Back Eligibility Investor-Owned Utility Rural Electric Cooperative Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Solar Home Weatherization Heating & Cooling Commercial Heating & Cooling Heating Wind Program Info State Kansas Program Type Renewables Portfolio Standard Provider Kansas Corporation Commission Kansas adopted the Renewable Energy Standards Act in 2009 (K.S.A. 66-1256), establishing a renewable portfolio standard (RPS). This statute requires the state's investor-owned and cooperative utilities to generate or purchase 10% of their electricity from eligible renewable resources in the years 2011-2015, 15% in the years 2016-2019, and 20% by 2020.

422

Renewable Electricity Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Renewable Electricity Standard Renewable Electricity Standard Renewable Electricity Standard < Back Eligibility Investor-Owned Utility Savings Category Bioenergy Biofuels Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Missouri Program Type Renewables Portfolio Standard Provider Missouri Public Service Commission In November 2008, voters in Missouri enacted Proposition C, a ballot initiative that repealed the state's existing voluntary renewable energy and energy efficiency objective and replaced it with an expanded, mandatory renewable electricity standard of 15% by 2021. The standard also contains a solar electricity carve-out of 2% of each interim portfolio requirement meaning that by 2021, 0.3% of retail electricity sales must be derived from

423

Energy Efficiency Resource Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Efficiency Resource Standard Energy Efficiency Resource Standard Energy Efficiency Resource Standard < Back Eligibility Investor-Owned Utility Municipal Utility Rural Electric Cooperative Savings Category Other Program Info State District of Columbia Program Type Energy Efficiency Resource Standard Provider Washington State Department of Commerce Washington voters passed [http://www.secstate.wa.gov/elections/initiatives/text/I937.pdf Initiative 937] in 2006, creating a [http://www.dsireusa.org/incentives/incentive.cfm?Incentive_Code=WA15R&re... renewable energy standard] and an energy efficiency resource standard for the state's electric utilities. Initiative 937 calls for electric utilities that serve more than 25,000 customers in the state of Washington to undertake all cost-effective energy conservation. Investor-owned utilities,

424

Standards Actions - August 2000  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Standards Standards Technical Standards Program Document Status (2000-07-31) (2000-07-31) (2000-07-31) (2000-07-31) (2000-07-31) Activity Summary In Conversion – 4 In Preparation – 32 Out for Comment – 15 Published this Month – 1 5-year Reviews Revisions in Progress – 3 Reaffirmations in Progress – 0 Supersedures in Progress – 6 Cancellations Pending – 8 Cancellations in Progress – 2 No Current Action – 35 Visit the Technical Standards Program Web Site: http://tis.eh.doe.gov/techstds/ DOE Technical Standards Project Initiated If you have any questions or are interested in participating in the development of this standard, please contact the person listed below. Complete listings of all DOE Technical Standards projects and their status are given in the Web Site referenced at the bottom of this page. To access these

425

April 2008 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3-27-2008 3-27-2008 Activity Summary In Conversion - 4 In Preparation - 24 Out for Comment - 26 Published in March - 0 Five Year Review status Proposed for Revision-4 Revision in Progress-3 Proposed for Reaffirmation-0 Reaffirmation in Progress-20 Cancellations Pending-6 Cancellations in Progress-0 Inside This Issue Visit the Technical Standards Program Web Site at http://www.hss.energy.gov/nuclear safety/techstds/ April 2008 Standards Actions 1.0 DOE Standards Actions The complete list of all DOE Technical Standards projects and their status is available on the Technical Standards Program (TSP) web page at http://hss.energy.gov/nuclear safetytechstds/. To access these standards, go to our web page, click on "DOE Technical Standards," then choose

426

IHS Standards Expert  

NLE Websites -- All DOE Office Websites (Extended Search)

Standards » Standards » IHS IHS Standards Expert1354608000000IHS Standards ExpertLANL researchers can access IHS Standards from offsite via Remote Access./No/Question? 667-5809library@lanl.gov IHS Standards Expert LANL researchers can access IHS Standards from offsite via Remote Access. Login For each collection (society), one person may access pdfs at a time, per the Library's subscription license. Please free up the collection for another user when finished: download or print your pdf, then Log Out. FAQs How do I use IHS? IHS Basic Tutorial (pdf) - see more on the "Training & Support" tab within IHS Contact IHS Customer support, 800-447-3352 (our Customer Support ID Number is 5926584) Contact the Research Library at 7-5809 or library@lanl.gov What if full-text is not available?

427

OSHA: Standards and Recordkeeping  

NLE Websites -- All DOE Office Websites (Extended Search)

OSHA: Standards & OSHA: Standards & Record keeping Frances E. Humphrey, CRNP, COHN-5/CM DOE Headquarters January 17, 2002 .. DOL Organizational Chart History of OSHA +11/14n8: Lead Standard Published * 5/23/80: Medical & Exposure Records Standard Finalized * 7/2/82: Voluntary Protection Programs (VPP) Created +11/25/83: HazCom Standard Promulgated * 9/1/89: Lockout/Tagout Standard Issued OSHA Mission Statement * "The mission of the Occupational Safety and Health Administration is to save lives, prevent injuries and protect the health of America's workers" {OSHA, 2001) History of OSHA +12/29nO: President Nixon signed Occupational Safety and Health Act of 1970 * 5129n1: First Standards Adopted * 1/17n2: OSHA Training Institute Established * Nov-Dec 1972: First State Plans Approved

428

Derived Concentration Technical Standard  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

196-2011 196-2011 April 2011 DOE STANDARD DERIVED CONCENTRATION TECHNICAL STANDARD U.S. Department of Energy AREA ENVR Washington, D.C. 20585 Not Measurement Sensitive This document is available on the Department of Energy Technical Standards Program Web Site at http://www.hss.doe.gov/nuclearsafety/ns/techstds/standard/standard.html DOE-STD-1196-2011 ACKNOWLEDGEMENTS This Derived Concentration Technical Standard was a collaborative effort sponsored by the DOE Office of Environmental Policy and Assistance, with support from Department subject matter experts (SMEs) in the field of radiation protection. This standard, which complements DOE Order (O) 458.1, Radiation Protection of the Public and the Environment, was developed taking

429

Standards Actions, May 2002  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4-29-2002 4-29-2002 Activity Summary In Conversion - 4 In Preparation - 47 Out for Comment - 12 Published this Month - 6 5-year Review Status Revision in Progress - 10 Reaffirmation in Progress - 12 Supersedure in Progress - 0 Cancellation Pending - 7 Cancellation in Progress - 1 No Current Action - 20 Inside this issue: DOE Technical Standards Proposed for Reaffirmation 1 DOE Technical Standards Re- cently Published 1 American National Standards Institute 2 American Society for Testing and Materials International 4 Visit the Technical Standards Program Web Site at http://tis.eh.doe.gov/techstds/. Standards Actions- May 2002 Standards Actions DOE Technical Standards Proposed for Reaffirmation The following documents are currently being reevaluated under the 5-year

430

May 2008 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4-25-2008 4-25-2008 Activity Summary In Conversion - 4 In Preparation - 24 Out for Comment - 26 Published in April - 2 Five Year Review status Proposed for Revision-4 Revision in Progress-3 Proposed for Reaffirmation-0 Reaffirmation in Progress-20 Cancellations Pending-6 Cancellations in Progress-0 Inside This Issue Visit the Technical Standards Program Web Site at http://www.hss.energy.gov/nuclear safety/techstds/ May 2008 Standards Actions 1.0 DOE Standards Actions The complete list of all DOE Technical Standards projects and their status is available on the Technical Standards Program (TSP) web page at http://hss.energy.gov/nuclear safetytechstds/. To access these standards, go to our web page, click on "DOE Technical Standards," then choose

431

Appliance Efficiency Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

6 6 Appliance Efficiency Standards Part 2 of 2: Policy process and consumer gains Part 1 of this article (CBS News, Spring 1995) discussed LBNL's role in setting federal appliance efficiency standards and presented an overview of the net national benefits of standards. Here, we examine the broader policy context for appliance standards and consumer benefits. Policy Context Appliance efficiency standards provide a minimum requirement for energy efficiency at the point of manufacture (or import). These standards seek to overcome market failures-including price distortions and transaction costs-that have historically given rise to a gap between observed and attainable product efficiencies. In this way, appliance standards complement information programs, utility DSM and other incentive programs,

432

July 2007 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

6-27-2007 6-27-2007 Activity Summary In Conversion - 4 In Preparation - 27 Out for Comment - 24 Published in June - 0 5-year Review status Proposed for Revision-5 Revision in Progress-6 Proposed forReaffirmation-1 Reaffirmation in Progress-21 Cancellations Pending-9 Cancellations in Progress-0 Inside This Issue Visit the Technical Standards Program Web Site at http://hss.energy.gov/nuclear safetytechstds/ July 2007 Standards Actions 1.0 DOE Standards Actions The complete list of all DOE Technical Standards projects and their status is available on the Technical Standards Program (TSP) web page at http://hss.energy.gov/nuclear safetytechstds/. To access these standards, go to our web page, click on "DOE Technical Standards," then choose

433

Standards Actions - August 2000  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Standards Standards Technical Standards Program Document Status (2000-07-31) (2000-07-31) (2000-07-31) (2000-07-31) (2000-07-31) Activity Summary In Conversion – 4 In Preparation – 32 Out for Comment – 15 Published this Month – 1 5-year Reviews Revisions in Progress – 3 Reaffirmations in Progress – 0 Supersedures in Progress – 6 Cancellations Pending – 8 Cancellations in Progress – 2 No Current Action – 35 Visit the Technical Standards Program Web Site: http://tis.eh.doe.gov/techstds/ DOE Technical Standards Project Initiated If you have any questions or are interested in participating in the development of this standard, please contact the person listed below. Complete listings of all DOE Technical Standards projects and their status are given in the Web Site referenced at the bottom of this page. To access these

434

Award Types  

NLE Websites -- All DOE Office Websites (Extended Search)

nuclear deterrent; reduce global threats; and solve other emerging national security and energy challenges. Contact Awards Team (505) 667-7824 Email Types of Awards The Awards...

435

Energy Efficiency Standards and Labels in North America: Opportunities for Harmonization  

E-Print Network (OSTI)

L mc ,S m L ve ** ,S m Dishwashers L mc ,L ve ,S m L mc ,LClothes washers Clothes washers and dryers DishwashersDishwashers Fluorescent lamp ballasts Fluorescent lamp

Wiel, Stephen

2008-01-01T23:59:59.000Z

436

Missouri Renewable Fuel Standard Brochure  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

The Missouri Renewable Fuel Standard The Missouri Renewable Fuel Standard requires ethanol in most gasoline beginning January 1, 2008. ARE YOU READY? TEN THINGS MISSOURI TANK OWNERS AND OPERATORS NEED TO KNOW ABOUT ETHANOL 1. Ethanol is a type of alcohol made usually from corn in Missouri and other states. 2. E10 is a blend of 10% ethanol and 90% unleaded gasoline. E85 is a blend of 75% to 85% fuel ethanol and 25% to 15% unleaded gasoline. Blends between E10 and E85 are not allowed to be sold at retail. 3. Any vehicle or small engine should run fine on E10, but only specially designed vehicles can use E85. 4. You are not required to label your dispensers disclosing the ethanol content if you are selling E10. However, you are required to label your dispensers if you are selling E85.

437

Standards Actions, October 2000  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Project Initiated Project Initiated If you have any questions or are interested in participating in the development of this standard, please contact the representatives listed below. Complete listings of all DOE Technical Standards projects and their status are given in the Technical Standards Pro- gram (TSP) Web Site referenced at the bottom of this page. To access these lists from the home page, click on “DOE Technical Standards,” then click on “Projects” in the left- hand frame to show the links to the project lists. The following DOE Technical Standards project was recently initiated: • Hoisting and Rigging Standard, Project Number SAFT-0077. This project is being pre- pared by the Hoisting and Rigging Technical Advisory Committee (HRTAC). If you de- sire to participate in this project, please contact your site representative to the HRTAC

438

October 2006 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Publication Staff Roster 2 Publication Staff Roster 2 DOE Technical Standards Program Document Status 09-26-2006 Activity Summary In Conversion - 4 In Preparation - 24 Out for Comment - 16 Published in September - 1 5-year Review Status Proposed for Revision-5 Revision in Progress-6 Proposed for reaffirmation-1 Reaffirmation in Progress-21 Cancellation Pending-9 Cancellation in Progress-0 Inside This Issue Visit the Technical Standards Program Web Site at http://www.eh.doe.gov/ techstds/ October 2006 Standards Actions 1.0 DOE Standards Actions The complete list of all DOE Technical Standards projects and their status is available on the Technical Standards Program (TSP) web page at http://www.eh.doe.gov/techstds/. To access

439

Jenseits des Standard Modells  

NLE Websites -- All DOE Office Websites (Extended Search)

The Standard Model The Standard Model Unngelöste Rätsel Jenseits des Standard Modells Das Standard Modell gibt auf viele Fragen, über Struktur und Stabilität der Materie eine Antwort. Dazu braucht es nur die sechs Sorten von Quarks und Leptonen und die vier fundamentalen Kräfte. Aber das Standard Modell ist nicht vollständig; es gibt noch viele unbeantwortete Fragen. Eigentlich sollten wir aus Gründen der Symmetrie im Weltraum gleichviel Materie wie Antimaterie beobachten. Wir finden aber praktisch nur normale Materie! Warum? Woraus besteht die "Dunkle Materie", die wir nicht sehen können, die aber im Universum sichtbare Gravitationswirkungen zeigt? Warum kann das Standard Modell die Massen der Teilchen nicht vorhersagen? Sind Quarks and Leptonen wirklich fundamentae Teilchen, oder sind sie aus noch elementareren Partikeln aufgebaut?

440

February 2001 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Standards Technical Standards Program Document Status Visit the Technical Standards Program Web Site: http://tis.eh.doe.gov/techstds/ Activity Summary In Conversion - 4 In Preparation - 35 Out for Comment - 18 Published this Month - 1 FY 2001 5-year Reviews Revisions in Progress - 2 Reaffirmations in Progress - 2 Supersedures in Progress - 6 Cancellations Pending - 11 Cancellations in Progress - 33 No Current Action - 16 DOE Technical Standards Project Canceled If you have any questions about this action, please contact the person listed be- low. The following DOE Technical Standards project was recently canceled: * EM Facility Hazard Categorization, Project Number SAFT-0029; EM Technical Standards Manager, John Serocki, 301-903-7999, John.Serocki@em.doe.gov, or Tom Wright, 301-903-3661, Tom.Wright@em.doe.gov. The need for this

Note: This page contains sample records for the topic "lamp type standard" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

August 2007 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Non-Government Standards Actions 1 American National Standards Institute (ANSI) 1 American Society of Mechanical Engineers (ASME) 2 ASTM International 2 American Nuclear Society (ANS) 2 National Fire Protection Association (NFPA) 2 Publication Staff Roster 2 DOE Technical Standards Program Document Status 07-27-2007 Activity Summary In Conversion - 4 In Preparation - 27 Out for Comment - 24 Published in June - 0 5-year Review status Proposed for Revision-5 Revision in Progress-6 Proposed for Reaffirmation-1 Reaffirmation in Progress-21 Cancellations Pending-9 Cancellations in Progress-0 Inside This Issue Visit the Technical Standards Program Web Site at

442

October 2007 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Non-Government Standards Actions 1 American National Standards Institute (ANSI) 1 American Society of Mechanical Engineers (ASME) 2 ASTM International 2 American Nuclear Society (ANS) 2 National Fire Protection Association (NFPA) 2 Publication Staff Roster 2 DOE Technical Standards Program Document Status 09-27-2007 Activity Summary In Conversion - 4 In Preparation - 26 Out for Comment - 27 Published in September - 0 5-year Review status Proposed for Revision-5 Revision in Progress-6 Proposed for Reaffirmation-1 Reaffirmation in Progress-21 Cancellations Pending-9 Cancellations in Progress-0 Inside This Issue Visit the Technical Standards Program Web Site at

443

April 2005 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Notices 1 Non-Government Standards Actions 1 American National Standards Institute (ANSI) 1 American Society of Mechanical Engineers (ASME) 1 ASTM International 2 American Nuclear Society (ANS) 2 National Fire Protection Association (NFPA) 2 DOE Technical Standards Program Document Status 3-28-2005 Activity Summary In Conversion - 4 In Preparation - 25 Out for Comment - 11 Published in March - 0 5-year Review Status Proposed for Revision-6 Revisions in Progress-4 Proposed for Reaffirmation-3 Reaffirmations in Progress-24 Cancellations Pending-11 Cancellations in Progress-0 Inside This Issue Visit the Technical Standards

444

August 2006 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Notices 1 DOE Technical Standards Published 1 Non-Government Standards Actions 2 American National Standards Institute (ANSI) 2 American Society of Mechanical Engineers (ASME) 2 ASTM International 2 American Nuclear Society (ANS) 2 National Fire Protection Association (NFPA) 2 DOE Technical Standards Program Document Status 07-26-2006 Activity Summary In Conversion - 4 In Preparation - 22 Out for Comment - 16 Published in July - 2 5-year Review Status Proposed for Revision-5 Revision in Progress-6 Proposed for reaffirmation-1 Reaffirmation in Progress-21 Cancellation Pending-9 Cancellation in Progress-0

445

primary frequency standards  

Science Conference Proceedings (OSTI)

NIST-F1 Cesium Fountain Atomic Clock The Primary Time and Frequency Standard for the United States. NIST-F1, the nation's ...

2013-02-04T23:59:59.000Z

446

Particulate Matter Standards (Ohio)  

Energy.gov (U.S. Department of Energy (DOE))

This chapter of the law that establishes the Ohio Environmental Protection Agency sets the standards for particulate emissions from a variety of sources, including facilities that generate power. ...

447

Columbia- Renewables Portfolio Standard  

Energy.gov (U.S. Department of Energy (DOE))

In November 2004, voters in Columbia, Missouri approved a proposal to adopt a local renewables portfolio standard (RPS).* The initiative requires the city's municipal utility, Columbia Water &...

448

Standards for Document Encasement  

Science Conference Proceedings (OSTI)

... time. We want the preservation community to be able to have a common set of standards to develop its own capabilities.. ...

2013-07-02T23:59:59.000Z

449

Vacuum Comparison Standard  

Science Conference Proceedings (OSTI)

... Manometers (UIMs), which are primary standards with the lowest stated uncertainty in the world, but require significant time and money to operate. ...

2012-11-16T23:59:59.000Z

450

Sustainability Standards Portal (SSP)  

Science Conference Proceedings (OSTI)

... A framework for analysis of standards from different perspectives. ... Dr. Jaehyun Lee Dr. Anantha Narayanan Dr. Paul Witherell Dr. Ram D. Sriram Ms ...

2010-11-15T23:59:59.000Z

451

ORISE: Standards development  

NLE Websites -- All DOE Office Websites (Extended Search)

of industry standards that provide guidance and support to decontamination and decommissioning projects across the United States. Because of our extensive experience...

452

Standard Administrative Procedures  

Science Conference Proceedings (OSTI)

... Standards surveillance and instrument monitoring projects. ... are normally stored in a LEVEL 1 security area must never be left unattended when they ...

2010-07-27T23:59:59.000Z

453

USING STANDARD SYSTE  

Science Conference Proceedings (OSTI)

... two-phase region for a symmetric blend ... density mismatch of fluid components and segregation ... Standards and Technology in the flow visualization. ...

2001-07-27T23:59:59.000Z

454

Alternative Energy Portfolio Standard  

Energy.gov (U.S. Department of Energy (DOE))

Pennsylvania's Alternative Energy Portfolio Standard (AEPS), created by S.B. 1030 on November 30, 2004, requires each electric distribution company (EDC) and electric generation supplier (EGS) to...

455

Site Lead TQP Standard  

NLE Websites -- All DOE Office Websites (Extended Search)

Qualification Standard for the Office of Safety and Emergency Management Evaluations Site Lead Program May 2011 Office of Enforcement and Oversight Office of Health, Safety and...

456

AND TIME STANDARDS  

Science Conference Proceedings (OSTI)

... mu- tual coupling between the units and to heater thermostat operations. ... resistance-bridge thermostats is planned for use in several new standard ...

2003-01-30T23:59:59.000Z

457

Large Standard Model Chart  

NLE Websites -- All DOE Office Websites (Extended Search)

Standard (tamao mediano) Principal ESTOY PERDIDO Ud puede solicitar una copia REAL de esta hermosa lmina Vea ampliaciones de componentes de la tabla y el texto que...

458

Large Standard Model Chart  

NLE Websites -- All DOE Office Websites (Extended Search)

Tabla del Modelo Standard (tamao mximo) Principal ESTOY PERDIDO Ud puede solicitar una copia REAL de esta hermosa lmina Vea ampliaciones de componentes de la tabla y el...

459

Standard Model Chart  

NLE Websites -- All DOE Office Websites (Extended Search)

Standard Volver Principal ESTOY PERDIDO Usted realmente no necesita memorizar todos los nombres de las partculas, ni cmo interactan, ni sus masas, etc. Sin embargo, a...

460

Fragen zum Standard Modell  

NLE Websites -- All DOE Office Websites (Extended Search)

Quiz What is Fundamental? Fragen zum Standard Modell Frage: Aus wievielen elementaren Teilchen sind die mehr als hundert bekannten Teilchen aufgebaut? Antwort 6 Quarks, 6 Leptonen,...

Note: This page contains sample records for the topic "lamp type standard" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Standard Model Quiz  

NLE Websites -- All DOE Office Websites (Extended Search)

los cientos de partculas conocidas? RESPUESTA: S, 6 quarks, 6 leptones, 6 antiquarks 6 antileptones, y los portadores de fuerza. Regreso a la ruta del Modelo Standard......

462

FEDERAL INFORMATION PROCESSING STANDARDS ...  

Science Conference Proceedings (OSTI)

... This Standard specifies use of a symmetric-key encryption ... definition of "escrow", the key component holders provide the components of a ...

2012-12-20T23:59:59.000Z

463

Standard Reference Materials:  

Science Conference Proceedings (OSTI)

... Statistical analyses of the physical properties from the ... Summary statistics: mean = 118.7 kgm3, standard ... were acquired in 1980 and 1981 for the ...

2012-04-26T23:59:59.000Z

464

Melanin Types  

NLE Websites -- All DOE Office Websites (Extended Search)

Melanin Types Melanin Types Name: Irfan Location: N/A Country: N/A Date: N/A Question: What are different types of melanins? And what are the functions of these types? Replies: Hi Irfan! Melanin is a dark compound or better a photoprotective pigment. Its major role in the skin is to absorb the ultraviolet (UV) light that comes from the sun so the skin is not damaged. Sun exposure usually produces a tan at the skin that represents an increase of melanin pigment in the skin. Melanin is important also in other areas of the body, as the eye and the brain., but it is not completely understood what the melanin pigment does in these areas. Melanin forms a special cell called melanocyte. This cell is found in the skin, in the hair follicle, and in the iris and retina of the eye.

465

Type systems  

Science Conference Proceedings (OSTI)

The study of type systems has emerged as one of the most active areas of research in programming languages, with applications in software engineering, language design, high-performance compiler implementation, and security. This chapter discusses the ...

Benjamin C. Pierce

2003-01-01T23:59:59.000Z

466

Standard Renewable Energy SRE | Open Energy Information  

Open Energy Info (EERE)

Standard Renewable Energy SRE Standard Renewable Energy SRE Jump to: navigation, search Name Standard Renewable Energy (SRE) Place Houston, Texas Zip 77007 Sector Renewable Energy, Services Product Houston-based provider of Distributed Energy Services Company (DESCO) for renewable energy services. Coordinates 29.76045°, -95.369784° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":29.76045,"lon":-95.369784,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

467

Journeys Beyond the Standard Model  

E-Print Network (OSTI)

Chapter 1 Introduction The Standard Model (SM) of Particleresults of searches for the standard model Higgs boson in ppunderstand new physics. The Standard Model is incom- plete;

Elor, Gilly

2013-01-01T23:59:59.000Z

468

Understanding Service Systems Through Standards  

E-Print Network (OSTI)

T. 2004. Economics of Standards in Information Networks.Kindleberger, C. P. 1983. Standards as Public, Collectivethe nature of today's standards. Presented at the

Mathew, Ashwin J.

2008-01-01T23:59:59.000Z

469

Nucleic Acid Standards - Standard Ref. Frame  

NLE Websites -- All DOE Office Websites (Extended Search)

A Standard Reference Frame for the Description A Standard Reference Frame for the Description of Nucleic Acid Base-pair Geometry Supplementary Material The report is available at Journal of Molecular Biology (2001) 313: 229 - 237 and The Nucleic Acid Cartesian coordinates for A, C, G, T, and U in the optimized reference frame Adenine, Cytosine, Guanine, Thymine, Uracil Standard chemical structures taken from Clowney et al. (1996), J. Am. Chem. Soc., 118, 509-518). These data do not include C1' atoms, which are placed here in the least-squares plane of the base atoms, with the purine C1'-N9 bond length and C1'-N9-C4 valence angle set respectively to 1.46 Å and 126.5° and the pyrimidine C1'-N1 bond and C1-N1-C2 angle to 1.47 Å and 118.1°. These distances and angles are based on the average glycosyl

470

June 2006 Standards Actions  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Page 1 June 2006 Page 1 June 2006 Technical Standards Program Manager's Note 1 Safety for Electrical Workers 2 Significant Federal Laws and Policies 3 Clearance of Solid Materials from Nuclear Facilities 5 Technical Standards Manager Spotlight 6 Topical Committee Developments 7 From the ANSI Web site 8 Don't Get "Board" With

471

C# Annotated Standard  

Science Conference Proceedings (OSTI)

Standards, while being definitive, do not usually serve as the best reference to the use of a programming language. Books on languages usually are able to explain usage better, but lack the definitive precision of a standard. This book combines the two; ... Keywords: C#, Computer Science, Programming, Programming Languages

Jon Jagger; Nigel Perry; Peter Sestoft

2007-07-01T23:59:59.000Z

472

Standards Development as Hybridization  

Science Conference Proceedings (OSTI)

While users in the rest of the World have been offered 3G mobile phones based on either the CDMA2000 or W-CDMA standards, users in China have the additional option of using phones based on the TD-SCDMA standard. As a technology largely developed by Chinese ... Keywords: Global, Hybridization, Indigenous, Innovation, Mobile Phones, National, Technology

Xiaobai Shen, Ian Graham, James Stewart, Robin Williams

2013-07-01T23:59:59.000Z

473

Universal software safety standard  

Science Conference Proceedings (OSTI)

This paper identifies the minimum subset required for a truly universal safety-critical software standard. This universal software standard could be used in but is not limited to the following application domains: commercial, military and space ... Keywords: software safety, system safety, validation, verification

P. V. Bhansali

2005-09-01T23:59:59.000Z

474

MODEL CONSERVATION STANDARD INTRODUCTION  

E-Print Network (OSTI)

standards and surcharge methodology. 2 The term "system cost" means an estimate of all direct costs and transmission to the consumer and, among other factors, waste disposal costs, end-of-cycle costs, and fuel costs. SURCHARGE RECOMMENDATION The Council does not recommend that the model conservation standards be subject

475

Hydrogen Codes and Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Codes and Standards Codes and Standards James Ohi National Renewable Energy Laboratory 1617 Cole Blvd. Golden, CO 80401 Background The development and promulgation of codes and standards are essential if hydrogen is to become a significant energy carrier and fuel because codes and standards are critical to establishing a market-receptive environment for commercializing hydrogen-based products and systems. The Hydrogen, Fuel Cells, and Infrastructure Technologies Program of the U.S. Department of Energy (DOE) and the National Renewable Energy Laboratory (NREL), with the help of the National Hydrogen Association (NHA) and other key stakeholders, are coordinating a collaborative national effort by government and industry to prepare, review, and promulgate hydrogen codes and standards needed to expedite hydrogen infrastructure development. The

476

Renewables Portfolio Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Renewables Portfolio Standard Renewables Portfolio Standard Renewables Portfolio Standard < Back Eligibility Investor-Owned Utility Municipal Utility Retail Supplier Rural Electric Cooperative Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Solar Wind Program Info State Delaware Program Type Renewables Portfolio Standard Provider Delaware Public Service Commission In 2005, [http://depsc.delaware.gov/electric/rpsact.pdf S.B. 74] established a renewables portfolio standard (RPS) requiring retail electricity suppliers to purchase 10% of the electricity sold in the state from renewable sources by 2019-2020 (the compliance year, or CY, runs from June - May). [http://legis.delaware.gov/LIS/lis144.nsf/vwLegislation/SB+19/$file/legis.html?open

477

Renewable Portfolio Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Portfolio Standard Portfolio Standard Renewable Portfolio Standard < Back Eligibility Investor-Owned Utility Savings Category Bioenergy Biofuels Alternative Fuel Vehicles Commercial Heating & Cooling Manufacturing Buying & Making Electricity Hydrogen & Fuel Cells Water Solar Heating & Cooling Water Heating Wind Program Info State New York Program Type Renewables Portfolio Standard Provider New York State Energy Research and Development Authority The New York Public Service Commission (PSC) adopted a renewable portfolio standard (RPS) in September 2004 and issued implementation rules in April 2005. As originally designed, New York's RPS had a renewables target of 25% of state electricity consumption by 2013, but was expanded in January 2010 to 30% by 2015 by order of the PSC. Of this 30%, approximately 20.7% of the

478

Energy Portfolio Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

You are here You are here Home » Energy Portfolio Standard Energy Portfolio Standard < Back Eligibility Investor-Owned Utility Retail Supplier Savings Category Bioenergy Biofuels Alternative Fuel Vehicles Buying & Making Electricity Water Solar Heating & Cooling Swimming Pool Heaters Water Heating Commercial Heating & Cooling Heating Wind Program Info State Nevada Program Type Renewables Portfolio Standard Provider Public Utilities Commission of Nevada Nevada established a renewable portfolio standard (RPS) as part of its 1997 restructuring legislation. Under the standard, NV Energy (formerly Nevada Power and Sierra Pacific Power) must use eligible renewable energy resources to supply a minimum percentage of the total electricity it sells. In 2001, the state increased the minimum requirement by 2% every two years,

479

Renewable Resource Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Renewable Resource Standard Renewable Resource Standard Renewable Resource Standard < Back Eligibility Investor-Owned Utility Retail Supplier Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Solar Wind Program Info State Montana Program Type Renewables Portfolio Standard Provider Montana Public Service Commission Montana's renewable portfolio standard (RPS), enacted in April 2005 as part of the Montana Renewable Power Production and Rural Economic Development Act, requires public utilities and competitive electricity suppliers to obtain a percentage of their retail electricity sales from eligible renewable resources according to the following schedule: * 5% for compliance years 2008-2009 (1/1/2008 - 12/31/2009) * 10% for compliance years 2010-2014 (1/1/2010 - 12/31/2014)

480

Renewable Energy Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Renewable Energy Standard Renewable Energy Standard Renewable Energy Standard < Back Eligibility Investor-Owned Utility Retail Supplier Rural Electric Cooperative Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Solar Heating & Cooling Heating Water Heating Wind Program Info State Arizona Program Type Renewables Portfolio Standard Provider Arizona Corporation Commission In November 2006, the Arizona Corporation Commission (ACC) adopted [http://images.edocket.azcc.gov/docketpdf/0000063561.pdf final rules] to expand the state's Renewable Energy Standard (RES) to 15% by 2025, with 30% of the renewable energy to be derived from distributed energy technologies (~2,000 megawatts). In June 2007, the state attorney general certified the

Note: This page contains sample records for the topic "lamp type standard" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Renewable Portfolio Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Portfolio Standard Portfolio Standard Renewable Portfolio Standard < Back Eligibility Investor-Owned Utility Municipal Utility Retail Supplier Rural Electric Cooperative Savings Category Bioenergy Buying & Making Electricity Water Alternative Fuel Vehicles Hydrogen & Fuel Cells Solar Wind Program Info State Oregon Program Type Renewables Portfolio Standard Provider Oregon Department of Energy As part of the Oregon Renewable Energy Act of 2007 ([http://www.leg.state.or.us/07reg/measpdf/sb0800.dir/sb0838.en.pdf Senate Bill 838]), the state of Oregon established a renewable portfolio standard (RPS) for electric utilities and retail electricity suppliers. Different RPS targets apply depending on a utility's size. Electricity service suppliers must meet the requirements applicable to the electric utilities

482

Renewable Energy Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Renewable Energy Standard Renewable Energy Standard Renewable Energy Standard < Back Eligibility Investor-Owned Utility Retail Supplier Savings Category Bioenergy Biofuels Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Solar Wind Program Info State Rhode Island Program Type Renewables Portfolio Standard Provider Rhode Island Office of Energy Resources Rhode Island's Renewable Energy Standard (RES), established in June 2004, requires the state's retail electricity providers -- including non-regulated power producers and distribution companies -- to supply 16% of their retail electricity sales from renewable resources by the end of 2019. The requirement began at 3% by the end of 2007, and then increases an additional 0.5% per year through 2010, an additional 1% per year from 2011

483

Energy Efficiency Portfolio Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Portfolio Standard Portfolio Standard Energy Efficiency Portfolio Standard < Back Eligibility Investor-Owned Utility Program Info State New York Program Type Energy Efficiency Resource Standard In May 2007 the New York Public Service Commission (PSC) issued an order instituting a proceeding to develop an Energy Efficiency Portfolio Standard (EEPS). The order set a goal of reducing electricity usage in New York by 15% from projected electricity usage in 2015. After examining comments and input from staff and stakeholders, the PSC issued a further order in June 2008 establishing detailed program targets, ratepayer collections to fund energy efficiency programs, and various other protocols for the EEPS. The June 2008 order also established collections from natural gas customers to

484

Puerto Rico - Interconnection Standards | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Puerto Rico - Interconnection Standards Puerto Rico - Interconnection Standards Puerto Rico - Interconnection Standards < Back Eligibility Agricultural Commercial Industrial Institutional Local Government Multi-Family Residential Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Wind Energy Sources Solar Home Weatherization Program Info Program Type Interconnection Provider Autoridad de Energía Electrica de Puerto Rico In 2007, the Autoridad de Energía Electrica de Puerto Rico (PREPA*) adopted interconnection standards based on the standard contained in the federal Energy Policy Act of 2005. PREPA promulgated interconnection rules in August 2008 that apply to all distributed generation (DG) projects that

485

Energy Efficiency Standard | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Efficiency Standard Efficiency Standard Energy Efficiency Standard < Back Eligibility Investor-Owned Utility Municipal Utility Retail Supplier Rural Electric Cooperative Utility Savings Category Other Program Info State Iowa Program Type Energy Efficiency Resource Standard Provider Iowa Utilities Board In 2008, Iowa enacted S.B. 2386, which requires the Iowa Utilities Board (IUB) to create energy savings standards (electricity and natural gas) for all rate-regulated utilities. The IUB ordered utilities to reduce retail sales by 1.5% of average sales f