Powered by Deep Web Technologies
Note: This page contains sample records for the topic "lamp sector lighting" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Flash Lighting with Fluorescent Lamp.  

E-Print Network (OSTI)

??A flash lighting circuit with the fluorescent lamp is designed to produce lighting flicker by means of controlling the operating frequency and the duty-ratio of… (more)

Hsieh, Horng

2005-01-01T23:59:59.000Z

2

Portable lamp with dynamically controlled lighting distribution  

DOE Patents (OSTI)

A double lamp table or floor lamp lighting system has a pair of compact fluorescent lamps (CFLs) arranged vertically with a reflective septum in between. By selectively turning on one or both of the CFLs, down lighting, up lighting, or both up and down lighting is produced. The control system can also vary the light intensity from each CFL. The reflective septum insures that almost all the light produced by each lamp will be directed into the desired light distribution pattern which is selected and easily changed by the user. Planar compact fluorescent lamps, e.g. circular CFLs, particularly oriented horizontally, are preferable. CFLs provide energy efficiency. The lighting system may be designed for the home, hospitality, office or other environments.

Siminovitch, Michael J. (Pinole, CA); Page, Erik R. (Berkeley, CA)

2001-01-01T23:59:59.000Z

3

Light Flicker in Compact Fluorescent Lamps Caused by Voltage Fluctuations  

Science Conference Proceedings (OSTI)

This power quality (PQ) case study presents tests performed at the EPRI Power Electronics Applications Center (PEAC) Power Quality Test Facility to characterize the light output of an incandescent lamp and compact fluorescent lamps during voltage fluctuations.

2003-12-31T23:59:59.000Z

4

Lighting Group: Sources and Ballasts: LED Reflector Lamp  

NLE Websites -- All DOE Office Websites (Extended Search)

LED Reflector Lamp LED Reflector Lamp LED Reflector Lamp Objective LED reflector lamp The goal of this project is to develop a revolutionary new reflector lamp which offers many advantages over current incandescent reflector lamps, including: three times greater efficiency ten times the rated life greater optical and performance properties use of light emitting diodes (LEDs) to generate the light. Although LEDs have been commercially available since the late 1960Â’s, recent dramatic improvements in LED technology have led to white light devices with efficiencies that meet or exceed those of a standard incandescent lamp. This project will build upon these improvements to develop a new type of source for focusing light. Contact Information For more information on this project, please contact:

5

New LED light sources and lamps for general illumination  

E-Print Network (OSTI)

of light source compared to traditional light sources like incandescent bulbs and fluorescent tubes bulb. LEDs emit colored light with a narrow spectral band of 20-30 nm, colors covering the spectralNew LED light sources and lamps for general illumination Carsten Dam-Hansen, Birgitte Thestrup

6

Power control architectures for cold cathode fluorescent lamp and light emitting diode based light sources.  

E-Print Network (OSTI)

?? In this dissertation, two different energy efficient power supply topologies are introduced for controlling cold cathode fluorescent lamp (CCFL) and high-brightness light emitting diode… (more)

Doshi, Montu V.

2010-01-01T23:59:59.000Z

7

Sulfur Lamps-The Next Generation of Efficient Light?  

NLE Websites -- All DOE Office Websites (Extended Search)

5 5 Sulfur Lamps-The Next Generation of Efficient Light? The figure above is a schematic of the system installed at the National Air and Space Museum and the DOE headquarters in Washington, D.C., Light from the sulfur lamp is focused by a parabolic reflector so that it enters the light pipe within a small angular cone. Light travels down the pipe, reflecting off the prismatic film (A) that lines the outer acrylic tube. The prismatic film reflects the light through total internal reflection (C), an intrinsically efficient process. Some of the light striking the film (at A) is not reflected and "leaks out" of the pipe walls (B), giving the pipe a glowing appearance. A light ray that travels all the way down the pipe will strike the mirror at the end (D) and return back up the pipe.

8

Solid-State Lighting: LED Replacement Lamps: Current Performance and the  

NLE Websites -- All DOE Office Websites (Extended Search)

LED Replacement Lamps: Current LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® to someone by E-mail Share Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Facebook Tweet about Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Twitter Bookmark Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Google Bookmark Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Delicious Rank Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Digg Find More places to share Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on

9

High Efficiency LED Lamp for Solid-State Lighting  

SciTech Connect

This report contains a summary of technical achievements during a three-year project to demonstrate high efficiency, solid-state lamps based on gallium nitride/silicon carbide light-emitting diodes. Novel chip designs and fabrication processes are described for a new type of nitride light-emitting diode with the potential for very high efficiency. This work resulted in the demonstration of blue light-emitting diodes in the one watt class that achieved up to 495 mW of light output at 350 mA drive current, corresponding to quantum and wall plug efficiencies of 51% and 45%, respectively. When combined with a phosphor in Cree's 7090 XLamp package, these advanced blue-emitting devices resulted in white light-emitting diodes whose efficacy exceeded 85 lumens per watt. In addition, up to 1040 lumens at greater than 85 lumens per watt was achieved by combining multiple devices to make a compact white lamp module with high optical efficiency.

James Ibbetson

2006-12-31T23:59:59.000Z

10

Mercury Lamps Recycling Fluorescent light-tubes, compact fluorescent bulbs, mercury and sodium vapor lamps, ultraviolet and  

E-Print Network (OSTI)

Mercury Lamps Recycling Fluorescent light-tubes, compact fluorescent bulbs, mercury and sodium light tubes are recycled. They are made from aluminum and metal. Aluminum is a silver-white metal and is very light in weight and strong. Because aluminum is ductile, it can be drawn into wires or pressed

Ungerleider, Leslie G.

11

Table lamp with dynamically controlled lighting distribution and uniformly illuminated luminous shade  

DOE Patents (OSTI)

A double lamp table or floor lamp lighting system has a pair of compact fluorescent lamps (CFLs) or other lamps arranged vertically, i.e. one lamp above the other, with a reflective septum in between. By selectively turning on one or both of the CFLs, down lighting, up lighting, or both up and down lighting is produced. The control system can also vary the light intensity from each CFL. The reflective septum ensures that almost all the light produced by each lamp will be directed into the desired light distribution pattern which is selected and easily changed by the user. In a particular configuration, the reflective septum is bowl shaped, with the upper CFL sitting in the bowl, and a luminous shade hanging down from the bowl. The lower CFL provides both task lighting and uniform shade luminance. Planar compact fluorescent lamps, e.g. circular CFLs, particularly oriented horizontally, are preferable. CFLs provide energy efficiency. However, other types of lamps, including incandescent, halogen, and LEDs can also be used in the fixture. The lighting system may be designed for the home, hospitality, office or other environments.

Siminovitch, Michael J. (Pinole, CA); Page, Erik R. (Berkeley, CA)

2002-01-01T23:59:59.000Z

12

Energy efficiency lighting on board naval ships: Phase 2 (The T-8 lamp system)  

SciTech Connect

This report describes the development and performance of the T-8 fluorescent lamp-ballast system. Similar to the Phase I effort, the cooperation of the lamp and ballast companies (GTE, North American Philips Lighting, and IOTA Engineering) were required for the successful result. The above companies submitted prototype lamps and ballasts to the Lawrence Berkeley Laboratory Lighting Group to evaluate. The lamp designs were modified as required and the optimum system selected. Two-lamp designs and one ballast were chosen and tested to determine if they met the Navy specifications. The second section describes the lamp-ballast specifications. This section includes the measured thermal performance from an ambient of 10/degree/C to 60/degree/C. 1 ref., 8 figs., 11 tabs.

Verderber, R.R.

1987-01-31T23:59:59.000Z

13

Performance of electronic ballasts and lighting controllers with 34-W fluorescent lamps: Final report  

SciTech Connect

This study has measured the performance of energy-saving 34-watt F40, T-12, rapid-start, lite white fluorescent lamps being operated by solid-state ballasts and lighting control equipment. The performances of these lamps are compared with those of 40-watt F40, T-12 rapid-start cool white fluorescent lamp systems studied in the prior phase of this project. With the 34-watt F40 lamps and various solid-state ballasts, system efficacy ranged from 67 to 84 lumens per watt and ballast factor from 0.756 to 0.908. Average system efficacy using the 34-watt lamps exceeded that of systems using 40-watt lamps and the same solid-state ballasts by only 1 percent even though the 34-watt lamps is about 6 percent more efficacious than the 40-watt lamp. This apparent discrepancy is due to increased ballast losses when operating the 34-watt lamps. However, the system efficacy of the 34-watt lamps used with a solid-state ballast exceeded that of a 34-watt, two-lamp system using the standard core-coil ballast by as much as 29 percent. A T-8 fluorescent lamp system with a smaller lamp diameter was also included in the study. Operating this lamp with a solid-state ballast produced a high system efficacy of 90 lumens per watt, a 39 percent improvement over the efficacy of a 40-watt F40 system using the standard core-coil ballast. The use of static controllers with 34-watt F40 lamps can result in excessive flickering (46 percent) and the generation of a second harmonic as high as 96 percent of the fundamental frequency. The dynamic controllers, when used to dim the 34-watt lamps generally cannot be dimmed as low as the 40-watt lamp system without flickering. In general, the 34-watt energy-saving lamps are appropriate as a retrofit to reduce illumination levels. However, for new construction, the 40-watt F40 argon filled lamps cost less, perform better, and provide a more reliable system. 5 refs., 27 figs., 9 tabs.

Verderber, R.R.

1988-06-01T23:59:59.000Z

14

A new optimized fluorescent lamp and ballast for low-energy general lighting applications  

SciTech Connect

A new fluorescent lamp and ballast system has been developed which minimizes system input power while maintaining light output close to values provided by conventional lamps and ballasts. The 28-WT-12 lamp designed for the new system utilizes a redesigned electrode structure which allows the lamp to be started in the rapid start manner but operated in an instant start mode to maximize the discharge efficacy (lumens/watt) while reducing lamp cathode power requirements. A matching two-lamp ballast incorporates a solid-state switching device to turn off the cathode heating circuit automatically once the lamps have started. Both lamps and ballasts are physically interchangeable with conventional equipment so that existing luminaires can be converted without luminaire, lampholder, and wiring modifications. This new lamp/ballast system can achieve efficacy values exceeding 80 lm/W--more than 25 percent better than the performance of conventional fluorescent systems of the early 1970's-along with the excellent life and reliability characteristics typical of electromagnetically ballasted systems. Economic analyses indicate that the new system is appropriate for many new commercial general lighting installations, although it is particularly suitable as a retrofit system for installations where power reductions are essential but where conversion costs must be minimized and illumination levels preserved.

Hammer, E.E.; McGowan, T.K.

1983-07-01T23:59:59.000Z

15

Potential Environmental Impacts from the Metals in Incandescent, Compact Fluorescent Lamp (CFL), and Light-Emitting Diode (LED)  

E-Print Network (OSTI)

), and Light-Emitting Diode (LED) Bulbs Seong-Rin Lim, Daniel Kang, Oladele A. Ogunseitan,,§ and Julie M sources with compact fluorescent lamp (CFL) and light-emitting diode (LED) bulbs that use about 70% and 85 lighting systems are transitioning from incandes- cent to compact fluorescent lamp (CFL) and light

Short, Daniel

16

A light diet for a giant appetite: An assessment of China's proposed fluorescent lamp standard  

SciTech Connect

Lighting has been one of the fastest growing electric end-uses in China over the last twenty years, with an average annual growth rate of 14%. Fluorescent lighting provides a significant portion of China's lighting need. In 1998, China produced 680 million fluorescent lamps, of which 420 million were linear fluorescent lamps of various diameters (T8 to T12). There are substantial variations both in energy efficiency and lighting performance among locally produced fluorescent lamps. Such variations present a perfect opportunity for policy intervention through efficiency standards to promote the adoption of more efficient fluorescent lamps in China. This paper analyzes China's proposed minimum efficiency standard for fluorescent lamps and presents an assessment of its likely impacts on China's lighting energy consumption and GHG emissions.

Lin, Jiang

2002-04-11T23:59:59.000Z

17

A high-efficiency indirect lighting system utilizing the solar 1000 sulfur lamp  

SciTech Connect

High-lumen light sources represent unique challenges and opportunities for the design of practical and efficient interior lighting systems. High-output sources require a means of large-scale distribution and avoidance of high-luminance glare while providing efficient delivery. An indirect lighting system has been developed for use with a 1,000 Watt sulfur lamp that efficiently utilizes the high-output source to provide quality interior lighting. This paper briefly describes the design and initial testing of this new system.

Siminovitch, M.; Gould, C.; Page, E.

1997-06-01T23:59:59.000Z

18

L&E - high efficiency lighting for parking structure | The Better Buildings  

NLE Websites -- All DOE Office Websites (Extended Search)

structure structure Activities Technology Solutions Teams Lighting & Electrical Space Conditioning Plug & Process Loads Food Service Refrigeration Laboratories Energy Management & Information Systems Public Sector Teams Market Solutions Teams Adopt high-efficiency lighting for your parking structure Parking structures and garages are typically lighted by older HID lighting technology without any energy-saving controls. The latest high-efficiency alternatives with energy-saving controls-including light-emitting diode (LED), induction, and fluorescent technology options-can save building owners over 40% on their parking lot lighting bills while delivering additional benefits such as better-lighted spaces. The Lighting & Electrical team developed a performance specification that

19

L&E: Adopt high-efficiency lighting for your parking lot | The Better  

NLE Websites -- All DOE Office Websites (Extended Search)

lot lot Activities Technology Solutions Teams Lighting & Electrical Space Conditioning Plug & Process Loads Food Service Refrigeration Laboratories Energy Management & Information Systems Public Sector Teams Market Solutions Teams Adopt high-efficiency lighting for your parking lot Most parking lots are illuminated by older high-intensity discharge (HID) lighting technology without any energy-saving controls. New light-emitting diode (LED) technology can cut parking lot lighting energy bills by 40%, or much more with controls, while delivering additional benefits including long life, reduced maintenance costs, and improved lighting uniformity. The Lighting & Electrical team developed a performance specification to help building owners take advantage of these improved lighting

20

Solid-State Lighting: LED Site Lighting in the Commercial Building Sector:  

NLE Websites -- All DOE Office Websites (Extended Search)

Site Lighting in the Site Lighting in the Commercial Building Sector: Opportunities, Challenges, and the CBEA Performance Specification to someone by E-mail Share Solid-State Lighting: LED Site Lighting in the Commercial Building Sector: Opportunities, Challenges, and the CBEA Performance Specification on Facebook Tweet about Solid-State Lighting: LED Site Lighting in the Commercial Building Sector: Opportunities, Challenges, and the CBEA Performance Specification on Twitter Bookmark Solid-State Lighting: LED Site Lighting in the Commercial Building Sector: Opportunities, Challenges, and the CBEA Performance Specification on Google Bookmark Solid-State Lighting: LED Site Lighting in the Commercial Building Sector: Opportunities, Challenges, and the CBEA Performance Specification on Delicious

Note: This page contains sample records for the topic "lamp sector lighting" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Transforming the Lighting Sector with Semiconductor Lighting Technologies  

NLE Websites -- All DOE Office Websites (Extended Search)

17-TED-000924-9/27 SR#2000-2333C 17-TED-000924-9/27 SR#2000-2333C Transforming the Lighting Sector With Semiconductor Lighting Technologies Thomas Drennen Sandia National Laboratories Roland Haitz Agilent Technologies Jeffrey Tsao E20 Communications Sandia National Laboratories USAEE/IAEE Annual Meetings Philadelphia, PA September 24-27, 2000 Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy under Contract DE-AC04-94AL85000 2 6217-TED-000924-9/27 SR#2000-2333C Overview * Introduction * U.S. Lighting Demand * Evolution of LEDs * The LED Simulation Model (LEDSim) * Results 3 6217-TED-000924-9/27 SR#2000-2333C Introduction 0 50 100 150 200 1970 1980 1990 2000 2010 2020 Efficiency (lm/W) Year Incandescent Halogen Fluorescent Semi- conductor

22

LED lamp  

SciTech Connect

There is herein described a lamp for providing white light comprising a plurality of light sources positioned on a substrate. Each of said light sources comprises a blue light emitting diode (LED) and a dome that substantially covers said LED. A first portion of said blue light from said LEDs is transmitted through said domes and a second portion of said blue light is converted into a red light by a first phosphor contained in said domes. A cover is disposed over all of said light sources that transmits at least a portion of said red and blue light emitted by said light sources. The cover contains a second phosphor that emits a yellow light in response to said blue light. The red, blue and yellow light combining to form the white light and the white light having a color rendering index (CRI) of at least about 80.

Galvez, Miguel; Grossman, Kenneth; Betts, David

2013-11-12T23:59:59.000Z

23

Assessment of Electrical, Efficiency, and Photometric Performance of Advanced Lighting Sources: Dimmable Advanced Lighting Technolog ies -- Electronic (Hot and Cold Cathode) Compact Fluorescent Lamps and Ballasts  

Science Conference Proceedings (OSTI)

This EPRI Technical Update (EPRI report 1018477) is one of four in a series that addresses basic dimming performance of advanced lighting sourceselectronic (hot and cold cathode) compact fluorescent lamps and ballasts Chapter 1 discusses basic lighting control, the importance of considering power quality in lighting control, lighting control methods and parameters, and the advantages and future of lighting control. Chapter 2 addresses in more depth dimming methods used in advanced lighting sources and co...

2008-12-19T23:59:59.000Z

24

L&E: Participate in a field test for high-efficiency troffer lighting. |  

NLE Websites -- All DOE Office Websites (Extended Search)

Lighting & Electrical » Participate Lighting & Electrical » Participate in a field test for high efficiency troffer lighting Activities Technology Solutions Teams Lighting & Electrical Space Conditioning Plug & Process Loads Food Service Refrigeration Laboratories Energy Management & Information Systems Public Sector Teams Market Solutions Teams Participate in a field test for high-efficiency troffer lighting 50% of all commercial fluorescent lighting fixtures are recessed troffers in 1'x4', 2'x2' and 2'x4' configurations, in operation for more than 10 hours a day on average and collectively consuming more than 87 TWh of electricity annually. The Lighting & Electrical team supported the market introduction of high-efficiency troffers by developing a specification that allows for

25

Aperture lamp  

DOE Patents (OSTI)

A discharge lamp includes means for containing a light emitting fill, the fill being capable of absorbing light at one wavelength and re-emitting the light at a different wavelength, the light emitted from the fill having a first spectral power distribution in the absence of reflection of light back into the fill; means for exciting the fill to cause the fill to emit light; and means for reflecting some of the light emitted by the fill back into the fill while allowing some light to exit, the exiting light having a second spectral power distribution with proportionately more light in the visible region as compared to the first spectral power distribution, wherein the light re-emitted by the fill is shifted in wavelength with respect to the absorbed light and the magnitude of the shift is in relation to an effective optical path length. Another discharge lamp includes an envelope; a fill which emits light when excited disposed in the envelope; a source of excitation power coupled to the fill to excite the fill and cause the fill to emit light; and a reflective ceramic structure disposed around the envelope and defining an light emitting opening, wherein the structure comprises a sintered body built up directly on the envelope and made from a combination of alumina and silica.

MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD)

2003-01-01T23:59:59.000Z

26

Performance of electronic ballasts and other new lighting equipment: (Phase 2, The 34-watt F40 rapid start T-12 fluorescent lamp): Final report  

SciTech Connect

This study has measured the performance of energy-saving 34-watt F40, T-12, rapid-start, lite white fluorescent lamps being operated by solid-state ballasts and lighting control equipment. The performances of these lamp systems are compared with those of 40-watt F40, T-12 rapid-start cool white fluorescent lamp systems studied in the prior phase of this project. With the 34-watt F40 lamps and various solid-state ballasts, system efficacy ranged from 67 to 84 lumens per watt and ballast factor from 0.756 to 0.908. Average system efficacy using the 34-watt lamps exceeded that of systems using 40-watt lamps and the same solid-state ballasts by only 1 percent even though the 34-watt lamps is about 6 percent more efficacious than the 40-watt lamp. This apparent discrepancy is due to increased ballast losses when operating the 34-watt lamps. However, the systems efficacy of the 34-watt lamps used with a solid-state ballast exceeded that of a 34-watt, two-lamp system using the standard core-coil ballast by as much as 29 percent. A T-8 fluorescent lamp system with a smaller lamp diameter was also included in the study. Operating this lamp with a solid-state ballast produced a high system efficacy of 90 lumens per watt, a 39 percent improvement over the efficacy of a 40-watt F40 system using the standard core-coil ballast. The use of static controllers with 34-watt F40 lamps can result in excessive flickering (46 percent) and the generation of a second harmonic as high as 96 percent of the fundamental frequency. The dynamic controllers, when used to dim the 34-watt lamps generally cannot be dimmed as low as the 40-watt lamp system without flickering. In general, the 34-watt energy-saving lamps are appropriate as a retrofit to reduce illumination levels. However, for new construction, the 40-watt F40 argon filled lamps cost less, perform better, and provide a more reliable system. 5 refs., 27 figs., 9 tabs.

Verderber, R.R.; Morse, O.

1988-02-01T23:59:59.000Z

27

Compact Fluorescent Lamps  

Science Conference Proceedings (OSTI)

Electric lighting constitutes approximately 21-23 % of the electric grid load in the United States. The higher energy and maintenance costs of incandescent lamps, combined with the favorable economics of high-efficiency compact fluorescent lamps (CFLs), are making CFLs the increasingly popular choice for both residential and commercial lighting. Utility incentive and rebate programs to stimulate CFL use and the beginnings of a ban on incandescent lamps are enhancing CFL penetration levels in these enviro...

2009-12-17T23:59:59.000Z

28

2X Incandescent Lamp Technology  

Science Conference Proceedings (OSTI)

The incandescent lamp was developed during the 1800s, largely reaching the design of the traditional incandescent lamp as we know it by the late 1800s. This lamp remained largely unchanged for years, providing most commercial and residential lighting demands into the 1950s and residential lighting into the 2000s. As new lighting technologies became available, the low efficacy, measured in lumens per watt, of the traditional incandescent lamp became an issue which many wanted to ...

2012-11-01T23:59:59.000Z

29

A projective LED dental lamp design.  

E-Print Network (OSTI)

??Halogen lamps are mostly applied as a light source to the traditional lamp for medical treatment due to its proper color temperature, but it has… (more)

Chung, Yu-Lin

2011-01-01T23:59:59.000Z

30

A light diet for a giant appetite: An assessment of China's proposed fluorescent lamp standard  

E-Print Network (OSTI)

Green Lights Program to promote efficient lighting products through public education, consumer incentives, national product testing, and investments

Lin, Jiang

2002-01-01T23:59:59.000Z

31

Research on the Best Market Applications for LightLab Energy-Saving Lamps.  

E-Print Network (OSTI)

?? Nowadays, lighting represents 20% of the global electricity consumption. Light can be produced using different technologies but more than 100 years after its invention,… (more)

Vilalta Cea, Raul

2010-01-01T23:59:59.000Z

32

Lighting Business Case -- A Report Analyzing Lighting Technology Opportunities with High Return on Investment Energy Savings for the Federal Sector  

SciTech Connect

This document analyzes lighting technology opportunities with high return on investment energy savings for the Federal sector.

Jones, Carol C.; Richman, Eric E.

2005-12-30T23:59:59.000Z

33

Tungsten Lamps as an Affordable Light Source for Testing of Photovoltaic Cells  

Science Conference Proceedings (OSTI)

An improved Tungsten light source system for photovoltaic cell testing made from low-cost, commercially available materials is presented as an alternative to standard expensive testing equipment. In this work, spectral correction of the Tungsten light ... Keywords: I-V measurement, Light source, Photovoltaic, Testing

Jeydmer Aristizabal; Badr Omrane; Clint Landrock; Sasan Vosoogh-Grayli; Yindar Chuo; Jasbir N. Patel; Bozena Kaminska; Carlo Menon

2011-06-01T23:59:59.000Z

34

Electronic Compact Fluorescent Lamps  

Science Conference Proceedings (OSTI)

This EPRI Technical Update addresses the fastest growing energy efficient light source the electronic compact fluorescent lamp (CFL). Business and technical market factors (Chapter 2) explain the past and future growth of the CFL market while emphasizing future technical improvements along with discussion of the importance of utility involvement in helping their customers make the switch from incandescent lamps to CFLs. The basic CFL technology is covered in Chapter 3 including test results for selected ...

2007-12-18T23:59:59.000Z

35

Side-by-Side Testing of Commercial Office Lighting Systems: Two-lamp Fluorescent Fixtures  

E-Print Network (OSTI)

Lighting systems in commercial office buildings are primary determinants of building energy use. In warmer climates, lighting energy use has important implications for building cooling loads as well as those directly associated with illumination tasks. To research the comparative performance of conventional and advanced office lighting systems, Florida Solar Energy Center (FSEC) set up the Lighting Flexible Test Facility (LFTF) which allows side-by-side comparison of lighting options in two otherwise identical 2.7 m x 3.7 m (9' x 12') south facing offices. The ceiling of the LFTF contains 0.61 m x 1.2 m (2' x 4') recessed fluorescent fixtures designed to be easily changed. Differing lighting systems were comparatively tested against each other over weeklong periods. Data on power consumption (watts), power quality (power factor), work-plane interior lighting levels (lux), bulb-wall, fixture and plenum temperatures were recorded every 15 minutes on a multi-channel data logger. This data allows realistic analysis of comparative lighting system performance including interactions with daylighting.

Parker, D. S.; Schrum, L.; Sonne, J. K.; Stedman, T. C.

1996-01-01T23:59:59.000Z

36

Fluorescent lamp dimming adaptor kit  

SciTech Connect

An add-on fluorescent lamp dimming adaptor is described for connecting to a conventional nondimming ballast in a fluorescent lighting system, the system including a source of ac voltage. The ballast has terminals for connecting to a fluorescent lamp, the adaptor comprising: a switching module adapted to be coupled to the terminals for switching current from the lamp, the switching module being connected in parallel with the lamp to divert current from the lamp when the switching module conducts; and a level control coupled to the switching module, the level control controlling the conductive state of the switching module to vary the current in the lamp according to a dimming control signal supplied to the level control, the level control causing the switching module to switch at a frequency in the range of 300 hertz and higher during times that the lamp current is being varied.

Alley, R.P.

1987-07-21T23:59:59.000Z

37

Driver Circuit for White LED Lamps with TRIAC Dimming Control.  

E-Print Network (OSTI)

??An efficient Light Emitting Diode (LED) lamp driver circuit is proposed for retrofitting the conventionally used incandescent lamps with existing TRIAC dimmer. The dimming feature… (more)

Weng, Szu-Jung

2012-01-01T23:59:59.000Z

38

Compact Fluorescent Lamps : Technologies : From the Lab to the...  

NLE Websites -- All DOE Office Websites (Extended Search)

process. (Left) Compact Fluorescent Lamp; (Right) Cover of the 'Lighting Retrofit Workbook' (Left) Compact Fluorescent Lamp (CFL) (Right) Retrofitting national parks...

39

Over the past decade, lighting became more efficient across ...  

U.S. Energy Information Administration (EIA)

"Other" includes light-emitting diode (LED) lamps as well as other lamps such as fiber optic lights, induction lamps, and lamps of unknown ...

40

Fixture conditions affect lamp performance  

SciTech Connect

This article discusses the major parameters that affect fluorescent lamp performance under fixture conditions. These parameters include fixture type, and HVAC integration, which directly determine the minimum lamp wall temperature (MLWT), and therefore, the resulting light output of the lamp/ballast system. Experimental data is presented showing that the lumen output of the lamp/ballast system can vary by as much as 20% and that the system efficacy can vary by 10% depending upon the type of fixture and HVAC system employed. 4 refs., 5 figs., 1 tab.

Siminovitch, M.J.; Rubinstein, F.M.; Verderber, R.R.

1986-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "lamp sector lighting" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Assessment of Electrical, Efficiency, and Photometric Performance of Advanced Lighting Sources: Dimmable Advanced Lighting Technolog ies -- Electronic Light-Emitting Diode (LED) Fixtures, Lamps, and Drivers  

Science Conference Proceedings (OSTI)

This EPRI Technical Update addresses the dimming performance of light-emitting diode (LED) lighting. Chapter 1 provides a discussion of basic lighting control, the importance of considering power quality in lighting control, lighting control methods and parameters, and the advantages and future of lighting control. Chapter 2 addresses in more depth the dimming methods used in advanced lighting sources and controls for incandescent, fluorescent, high-intensity discharge (HID) and LED sources. Chapter 3 ad...

2008-12-19T23:59:59.000Z

42

Over the past decade, lighting became more efficient across all sectors |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Over the past decade, lighting became more efficient across all Over the past decade, lighting became more efficient across all sectors Over the past decade, lighting became more efficient across all sectors May 10, 2012 - 2:54pm Addthis Source: U.S. Energy Information Administration, based on Department of Energy 2010 U.S. Lighting Market Characterization Source: U.S. Energy Information Administration, based on Department of Energy 2010 U.S. Lighting Market Characterization Source: U.S. Energy Information Administration, based on Department of Energy 2010 U.S. Lighting Market Characterization.

43

Energy saving controller for fluorescent lamps.  

E-Print Network (OSTI)

??Although fluorescent lamp is a very efficient lighting device in daily life, still the high harmonic distortion and low power factor cause unnecessary energy consumption.… (more)

Cheong, Zhi Xiong

2010-01-01T23:59:59.000Z

44

Lamp Divisions  

Office of Legacy Management (LM)

--- --- /A;; i :' r%i;in~house ilEc;' i:Z3:~cra:ion Lamp Divisions , _.. (I +i. 0 :,,,rg. . I . . -= i?e p/q! qe)-' &se pw E.rcale?l iev, Je!sey 07m March 20, 1 gs? ::r . J. A. Jones I ti. 5. Muclear Regulatory Commission .> = ..- haterials Licensing Branch -s - ,.I, - - Division of Fuel Cycle and hateri al Safety LY. , $2 - _ . ' -' . 3 _- - Yeshington, C. C. 2@555 - :_ :--, =-- -- .-?J -.: y...., : :- 7 Dear Mr. Jones : y-- --, ? . *I 2=15 2 r; X -P The following is our final report of the decontamination efZor?s takz in our Bui Iding 7 basement and wi 11 also serve to update our report i& November 12, 1980. As stated in NRC' s report of December 22, 1983, two closeout inspect ions were conducted by your King of Prussia off i ce on November 21 and December 2,

45

Stadiums and arenas use efficient, high wattage lamps - Today ...  

U.S. Energy Information Administration (EIA)

Other lighting types, such as light-emitting diode (LED), incandescent, and halogen lamps, are used in applications like signals, signage, ...

46

Laboratory Evaluation of LED T8 Replacement Lamp Products  

Science Conference Proceedings (OSTI)

A report on a lab setting analysis involving LED lamps intended to directly replace T8 fluorescent lamps (4') showing light output, power, and economic comparisons with other fluorescent options.

Richman, Eric E.; Kinzey, Bruce R.; Miller, Naomi J.

2011-05-23T23:59:59.000Z

47

Advanced Light Sources  

Science Conference Proceedings (OSTI)

In the generation of artificial light using electric lamps, photometric and color performance have been paramount in lamp design, manufacturing, measurement, lighting design, and visual perception. Many designers and researchers have strived to understand how light and color are generated, related, and to improve them. This has stemmed from the development of incandescent lamps, halogen lamps, linear fluorescent lamps, high-intensity discharge (HID) lamps, and compact fluorescent lamps (CFLs) among other...

2008-03-31T23:59:59.000Z

48

Demonstration Assessment of Light-Emitting Diode (LED) Retrofit Lamps at the Lobby of the Bonneville Power Administration, Portland, OR  

SciTech Connect

This report describes the process and results of a demonstration of solid-state lighting (SSL) technology in the lobby of the Bonneville Power Administration (BPA) headquarters building in Portland, Oregon. The project involved a simple retrofit of 32 track lights used to illuminate historical black-and-white photos and printed color posters from the 1930s and 1940s. BPA is a federal power marketing agency in the Northwestern United States, and selected this prominent location to demonstrate energy efficient light-emitting diode (LED) retrofit options that not only can reduce the electric bill for their customers but also provide attractive alternatives to conventional products, in this case accent lighting for BPA's historical artwork.

Miller, Naomi

2011-07-01T23:59:59.000Z

49

Demonstration Assessment of Light-Emitting Diode (LED) Retrofit Lamps at Intercontinental Hotel in San Francisco, CA  

SciTech Connect

This document is a report of observations and results obtained from a lighting demonstration project conducted under the U.S. Department of Energy (DOE) GATEWAY Demonstration Program. The program supports demonstrations of high-performance solid-state lighting (SSL) products in order to develop empirical data and experience with in-the-field applications of this advanced lighting technology. The DOE GATEWAY Demonstration Program focuses on providing a source of independent, third-party data for use in decision-making by lighting users and professionals; this data should be considered in combination with other information relevant to the particular site and application under examination. Each GATEWAY Demonstration compares SSL products against the incumbent technologies used in that location. Depending on available information and circumstances, the SSL product may also be compared to alternate lighting technologies. Though products demonstrated in the GATEWAY program have been prescreened and tested to verify their actual performance, DOE does not endorse any commercial product or in any way guarantee that users will achieve the same results through use of these products.

Miller, Naomi J.; Curry, Ku'Uipo J.

2010-11-01T23:59:59.000Z

50

Visible Light Digital Camera --Up to 2.3MP resolution with LED lamps provides sharp images  

E-Print Network (OSTI)

regardless of lighting conditions · Fusion Picture in Picture (PIP) -- Displays thermal image super Marker Function · Auto Hot/Cold spot marker function shows a spot within the area that automatically finds the hottest or coldest spot within the box i-Series Features FLIR i60 -- Scalable Fusion picture

Short, Daniel

51

Environmental impacts of lighting technologies - Life cycle assessment and sensitivity analysis  

SciTech Connect

With two regulations, 244/2009 and 245/2009, the European Commission recently put into practice the EuP Directive in the area of lighting devices, aiming to improve energy efficiency in the domestic lighting sector. This article presents a comprehensive life cycle assessment comparison of four different lighting technologies: the tungsten lamp, the halogen lamp, the conventional fluorescent lamp and the compact fluorescent lamp. Taking advantage of the most up-to-date life cycle inventory database available (ecoinvent data version 2.01), all life cycle phases were assessed and the sensitivity of the results for varying assumptions analysed: different qualities of compact fluorescent lamps (production phase), different electricity mixes (use phase), and end-of-life scenarios for WEEE recycling versus municipal solid waste incineration (disposal phase). A functional unit of 'one hour of lighting' was defined and the environmental burdens for the whole life cycle for all four lamp types were calculated, showing a clearly lower impact for the two gas-discharge lamps, i.e. the fluorescent and the compact fluorescent lamp. Differences in the product quality of the compact fluorescent lamps reveal to have only a very small effect on the overall environmental performance of this lamp type; a decline of the actual life time of this lamp type doesn't result in a change of the rank order of the results of the here examined four lamp types. It was also shown that the environmental break-even point of the gas-discharge lamps is reached long before the end of their expected life-span. All in all, it can be concluded that a change from today's tungsten lamp technology to a low-energy-consuming technology such as the compact fluorescent lamp results in a substantial environmental benefit.

Welz, Tobias; Hischier, Roland, E-mail: Roland.Hischier@empa.ch; Hilty, Lorenz M.

2011-04-15T23:59:59.000Z

52

Transportation Energy Futures Series: Potential for Energy Efficiency Improvement Beyond the Light-Duty-Vehilce Sector  

NLE Websites -- All DOE Office Websites (Extended Search)

COMMERCIAL TRUCKS COMMERCIAL TRUCKS AVIATION MARINE MODES RAILROADS PIPELINES OFF-ROAD EQUIPMENT Potential for Energy Efficiency Improvement Beyond the Light-Duty-Vehicle Sector TRANSPORTATION ENERGY FUTURES SERIES: Potential for Energy Efficiency Improvement Beyond the Light-Duty-Vehicle Sector A Study Sponsored by U.S. Department of Energy Office of Energy Efficiency and Renewable Energy February 2013 Prepared by ARGONNE NATIONAL LABORATORY Argonne, IL 60439 managed by U Chicago Argonne, LLC for the U.S. DEPARTMENT OF ENERGY under contract DE-AC02-06CH11357 This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, expressed or implied, or assumes any legal liability or

53

LED LAMP OR BULB WITH REMOTE PHOSPHOR AND DIFFUSER ...  

An LED lamp or bulb is disclosed that comprises a light source, a heat sink structure and an optical cavity. The optical cavity comprises a phosphor ...

54

Heat transfer assembly for a fluorescent lamp and fixture  

DOE Patents (OSTI)

In a lighting fixture including a lamp and a housing, a heat transfer structure is disclosed for reducing the minimum lamp wall temperature of a fluorescent light bulb. The heat transfer structure, constructed of thermally conductive material, extends from inside the housing to outside the housing, transferring heat energy generated from a fluorescent light bulb to outside the housing where the heat energy is dissipated to the ambient air outside the housing. Also disclosed is a method for reducing minimum lamp wall temperatures. Further disclosed is an improved lighting fixture including a lamp, a housing and the aforementioned heat transfer structure. 11 figs.

Siminovitch, M.J.; Rubenstein, F.M.; Whitman, R.E.

1992-12-29T23:59:59.000Z

55

Heat transfer assembly for a fluorescent lamp and fixture  

DOE Patents (OSTI)

In a lighting fixture including a lamp and a housing, a heat transfer structure is disclosed for reducing the minimum lamp wall temperature of a fluorescent light bulb. The heat transfer structure, constructed of thermally conductive material, extends from inside the housing to outside the housing, transferring heat energy generated from a fluorescent light bulb to outside the housing where the heat energy is dissipated to the ambient air outside the housing. Also disclosed is a method for reducing minimum lamp wall temperatures. Further disclosed is an improved lighting fixture including a lamp, a housing and the aforementioned heat transfer structure.

Siminovitch, Michael J. (Richmond, CA); Rubenstein, Francis M. (Berkeley, CA); Whitman, Richard E. (Richmond, CA)

1992-01-01T23:59:59.000Z

56

Energy Basics: Fluorescent Lighting  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

& Cooling Water Heating Fluorescent Lighting Fluorescent lamps use 25%-35% of the energy used by incandescent lamps to provide the same amount of illumination (efficacy of...

57

Compact fluorescent lamp using horizontal and vertical insulating septums and convective venting geometry  

DOE Patents (OSTI)

A novel design is described for a compact fluorescent lamp, including a lamp geometry which will increase light output and efficacy of the lamp in a base down operating position by providing horizontal and vertical insulating septums positioned in the ballast compartment of the lamp to provide a cooler coldspot. Selective convective venting provides additional cooling of the ballast compartment. 9 figs.

Siminovitch, M.

1998-02-10T23:59:59.000Z

58

Compact fluorescent lamp using horizontal and vertical insulating septums and convective venting geometry  

SciTech Connect

A novel design for a compact fluorescent lamp, including a lamp geometry which will increase light output and efficacy of the lamp in a base down operating position by providing horizontal and vertical insulating septums positioned in the ballast compartment of the lamp to provide a cooler coldspot. Selective convective venting provides additional cooling of the ballast compartment.

Siminovitch, Michael (El Sobrante, CA)

1998-01-01T23:59:59.000Z

59

Discharge lamp with reflective jacket  

DOE Patents (OSTI)

A discharge lamp includes an envelope, a fill which emits light when excited disposed in the envelope, a source of excitation power coupled to the fill to excite the fill and cause the fill to emit light, and a reflector disposed around the envelope and defining an opening, the reflector being configured to reflect some of the light emitted by the fill back into the fill while allowing some light to exit through the opening. The reflector may be made from a material having a similar thermal index of expansion as compared to the envelope and which is closely spaced to the envelope. The envelope material may be quartz and the reflector material may be either silica or alumina. The reflector may be formed as a jacket having a rigid structure which does not adhere to the envelope. The lamp may further include an optical clement spaced from the envelope and configured to reflect an unwanted component of light which exited the envelope back into the envelope through the opening in the reflector. Light which can be beneficially recaptured includes selected wavelength regions, a selected polarization, and selected angular components.

MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD); Kipling, Kent (Gaithersburg, MD)

2001-01-01T23:59:59.000Z

60

U.S. Energy Information Administration (EIA) - Sector  

Annual Energy Outlook 2012 (EIA)

incandescent bulbs. High-performance incandescent, compact fluorescent, and light-emitting diode (LED) lamps continue to replace low-efficacy incandescent lamps. In 2035,...

Note: This page contains sample records for the topic "lamp sector lighting" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Jacketed lamp bulb envelope  

DOE Patents (OSTI)

A jacketed lamp bulb envelope includes a ceramic cup having an open end and a partially closed end, the partially closed end defining an aperture, a lamp bulb positioned inside the ceramic cup abutting the aperture, and a reflective ceramic material at least partially covering a portion of the bulb not abutting the aperture. The reflective ceramic material may substantially fill an interior volume of the ceramic cup not occupied by the bulb. The ceramic cup may include a structural feature for aiding in alignment of the jacketed lamp bulb envelope in a lamp. The ceramic cup may include an external flange about a periphery thereof. One example of a jacketed lamp bulb envelope includes a ceramic cup having an open end and a closed end, a ceramic washer covering the open end of the ceramic cup, the washer defining an aperture therethrough, a lamp bulb positioned inside the ceramic cup abutting the aperture, and a reflective ceramic material filling an interior volume of the ceramic cup not occupied by the bulb. A method of packing a jacketed lamp bulb envelope of the type comprising a ceramic cup with a lamp bulb disposed therein includes the steps of filling the ceramic cup with a flowable slurry of reflective material, and applying centrifugal force to the cup to pack the reflective material therein.

MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD); Gitsevich, Aleksandr (Gaithersburg, MD); Bass, Gary K. (Mt. Airy, MD); Dolan, James T. (Frederick, MD); Kipling, Kent (Gaithersburg, MD); Kirkpatrick, Douglas A. (Great Falls, VA); Leng, Yongzhang (Damascus, MD); Levin, Izrail (Silver Spring, MD); Roy, Robert J. (Frederick, MD); Shanks, Bruce (Gaithersburg, MD); Smith, Malcolm (Alexandria, VA); Trimble, William C. (Columbia, MD); Tsai, Peter (Olney, MD)

2001-01-01T23:59:59.000Z

62

A Light Supersymmetric Higgs Sector Hidden by a Standard Model-like Higgs  

E-Print Network (OSTI)

Extending the Higgs sector of the MSSM by triplets alleviates the little hierarchy problem and naturally allows for enhancements in the diphoton decay rate of the lightest CP-even Higgs h. In the present paper we analyze in detail the Higgs phenomenology of this theory with m_h~126 GeV. We mostly focus on a light Higgs sector where the pseudoscalar A, the next-to-lightest CP-even scalar H and the charged H^\\pm Higgses are naturally at the electroweak scale. It turns out that for any value m_A > m_h there is a parameter region at small tan(beta) where the CP-even Higgs sector appears at colliders as the SM one, except for loop-induced corrections. Notably the existence of this SM-like point, which is absent in the MSSM, is shared with supersymmetric theories where there are extra singlets. We also highlight a second parameter region at small m_A and small tan(beta) where the h signal strengths, diphoton channel included, are SM-like except those of bottoms and taus which can have at most a 10-15 % splitting. Improvements in the A and H^\\pm searches are worthwhile in order to discriminate this scenario from the SM.

Antonio Delgado; Germano Nardini; Mariano Quiros

2013-03-04T23:59:59.000Z

63

Lamp method and apparatus using multiple reflections  

DOE Patents (OSTI)

A method wherein the light in a sulfur or selenium lamp is reflected through the fill a multiplicity of times to convert ultraviolet radiation to visible is disclosed. A light emitting device comprised of an electrodeless envelope which bears a light reflecting covering around a first portion which does not crack due to differential thermal expansion and which has a second portion which comprises a light transmissive aperture. 20 figs.

MacLennan, D.A.; Turner, B.; Kipling, K.

1999-05-11T23:59:59.000Z

64

Lamp method and apparatus using multiple reflections  

DOE Patents (OSTI)

A method wherein the light in a sulfur or selenium lamp is reflected through the fill a multiplicity of times to convert ultraviolet radiation to visible. A light emitting device comprised of an electrodeless envelope which bears a light reflecting covering around a first portion which does not crack due to differential thermal expansion and which has a second portion which comprises a light transmissive aperture.

MacLennan, Donald A. (Butler, PA); Turner, Brian (Damascus, MD); Kipling, Kent (Gaithersburg, MD)

1999-01-01T23:59:59.000Z

65

Section 5.4.1 Linear Fluorescent Lighting: Greening Federal Facilities...  

NLE Websites -- All DOE Office Websites (Extended Search)

and color temperature. When specifying a lighting sys- tem, be sure that the lamp and ballast are electrically matched and the lamp and fixture optically matched. Fluorescent lamp...

66

Observed Minimum Illuminance Threshold for Night Market Vendors in Kenya who use LED Lamps  

E-Print Network (OSTI)

the economics of fuel-based and LED lighting technology fordata logger equipped rechargeable LED lamps, monitoring theadoption of the LED lamps, and a follow-up survey. 1 Figure

Johnstone, Peter

2009-01-01T23:59:59.000Z

67

Fluorescent lamp ballast  

SciTech Connect

An electronic ballast is described having at least a first and second terminal for engaging the filaments of at least one fluorescent lamp which requires a breakdown voltage to ignite the lamp and a maintaining voltage for maintaining ionization therewithin, the electronic ballast comprising: a direct current voltage source; a transistor; a transformer having a primary winding separated into a first winding, a second winding, a third winding, and a fourth winding; the first winding connected between the voltage source and the first terminal; the second winding connected between the two terminals; the third winding connected between the second terminal and to both the transistor and to ground; the fourth winding connected between ground and the transistor; the lamp being parallel to the second winding when the lamp filaments engages the ballast terminals.

Ureche, A.

1987-08-25T23:59:59.000Z

68

Magnetic fluorescent lamp  

DOE Patents (OSTI)

The radiant emission of a mercury-argon discharge in a fluorescent lamp assembly is enhanced by providing means for establishing a magnetic field with lines of force along the path of electron flow through the bulb of the lamp assembly, to provide Zeeman splitting of the ultraviolet spectral line. Optimum results are obtained when the magnetic field strength causes a Zeeman splitting of approximately 1.7 times the thermal line width.

Berman, S.M.; Richardson R.W.

1983-12-29T23:59:59.000Z

69

New and Underutilized Technology: Spectrally Enhanced Lighting | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Spectrally Enhanced Lighting Spectrally Enhanced Lighting New and Underutilized Technology: Spectrally Enhanced Lighting October 4, 2013 - 4:50pm Addthis The following information outlines key deployment considerations for spectrally enhanced lighting within the Federal sector. Benefits U.S. Department of Energy (DOE) research studies show that simply shifting the color of fluorescent lamps from the warmer yellow to the cooler blue end of the color spectrum allows people to see things more clearly and for spaces to appear brighter. By changing the light color to be more like daylight, lighting levels can be reduced to save energy while still achieving the same visual acuity. Conventional practices use lamps with correlated color temperature (CCT) of 3,000K to 4,100K. Spectrally enhanced lighting uses lamps with a CCT of

70

Lamp bulb with integral reflector  

SciTech Connect

An improved electrodeless discharge lamp bulb includes an integral ceramic reflector as a portion of the bulb envelope. The bulb envelope further includes two pieces, a reflector portion or segment is cast quartz ceramic and a light transmissive portion is a clear fused silica. In one embodiment, the cast quartz ceramic segment includes heat sink fins or stubs providing an increased outside surface area to dissipate internal heat. In another embodiment, the quartz ceramic segment includes an outside surface fused to eliminate gas permeation by polishing.

Levin, Izrail (Silver Spring, MD); Shanks, Bruce (Gaithersburg, MD); Sumner, Thomas L. (Wheaton, MD)

2001-01-01T23:59:59.000Z

71

Arnold Schwarzenegger LIGHTING RESEARCH PROGRAM  

E-Print Network (OSTI)

fluorescent task lamp. The prototype used commercially available materials: 1watt light emitting diodes to the mounting board. Development of LightEmitting Diode Task Lamp using Advanced Technologies: Prototype 2 lightemitting diode task lamp. The problem of developing an energy efficient light emitting diode task lamp

72

Energy Performance of Compact Fluorescent Lamps  

Science Conference Proceedings (OSTI)

This power quality (PQ) case study presents the results of tests performed at the Worcester Polytechnic Institute, in contract with the EPRI Power Electronics Applications Center (PEAC), to determine the light output, power consumption, efficiency, and power factor of off-the-shelf electronic and magnetic compact fluorescent lamps.

2003-12-31T23:59:59.000Z

73

Fluorescent lamp ballast  

SciTech Connect

This patent describes an electronic ballast unit for a fluorescent lamp comprising: a circuit assembly having a pair of voltage input terminal and a first inductor and a capacitor in series relationship with each other to form a series resonant circuit. The circuit is adapted to be coupled to a fluorescent lamp to provide a starting voltage for the lamp; and a second inductor connected in shunt relationship to the first inductor and connected to the other input terminal. There is a core on which the first inductor and the second inductor are mounted. The core inductively couples the inductors with each other and are shaped to reduce core losses to minimize the increase of temperature of the core; the core is of a generally H-shaped configuration, and means of opposite ends of the H-shaped core to complete the magnetic flux path for each inductor, respectively.

Boyd, G.D.

1987-03-31T23:59:59.000Z

74

Max Tech and Beyond: High-Intensity Discharge Lamps  

Science Conference Proceedings (OSTI)

High-intensity discharge (HID) lamps are most often found in industrial and commercial applications, and are the light source of choice in street and area lighting, and sports stadium illumination. HID lamps are produced in three types - mercury vapor (MV), high pressure sodium (HPS) and metal halide (MH). Of these, MV and MH are considered white-light sources (although the MV exhibits poor color rendering) and HPS produces a yellow-orange color light. A fourth lamp, low-pressure sodium (LPS), is not a HID lamp by definition, but it is used in similar applications and thus is often grouped with HID lamps. With the notable exception of MV which is comparatively inefficient and in decline in the US from both a sales and installed stock point of view; HPS, LPS and MH all have efficacies over 100 lumens per watt. The figure below presents the efficacy trends over time for commercially available HID lamps and LPS, starting with MV and LPS in 1930's followed by the development of HPS and MH in the 1960's. In HID lamps, light is generated by creating an electric arc between two electrodes in an arc tube. The particles in the arc are partially ionized, making them electrically conductive, and a light-emitting 'plasma' is created. This arc occurs within the arc tube, which for most HID lamps is enclosed within an evacuated outer bulb that thermally isolates and protects the hot arc tube from the surroundings. Unlike a fluorescent lamp that produces visible light through down-converting UV light with phosphors, the arc itself is the light source in an HID lamp, emitting visible radiation that is characteristic of the elements present in the plasma. Thus, the mixture of elements included in the arc tube is one critical factor determining the quality of the light emitted from the lamp, including its correlated color temperature (CCT) and color rendering index (CRI). Similar to fluorescent lamps, HID lamps require a ballast to start and maintain stable operating conditions, and this necessitates additional power beyond that used by the lamp itself. HID lamps offer important advantages compared to other lighting technologies, making them well suited for certain applications. HID lamps can be very efficient, have long operating lives, are relatively temperature-insensitive and produce a large quantity of light from a small package. For these reasons, HID lamps are often used when high levels of illumination are required over large areas and where operating and maintenance costs must be kept to a minimum. Furthermore, if the installation has a significant mounting height, high-power HID lamps can offer superior optical performance luminaires, reducing the number of lamps required to illuminate a given area. The indoor environments best suited to HID lamps are those with high ceilings, such as those commonly found in industrial spaces, warehouses, large retail spaces, sports halls and large public areas. Research into efficacy improvements for HID lighting technologies has generally followed market demand for these lamps, which is in decline for MV and LPS, has reached a plateau for HPS and is growing for MH. Several manufacturers interviewed for this study indicated that although solid-state lighting was now receiving the bulk of their company's R&D investment, there are still strong HID lamp research programs, which concentrate on MH technologies, with some limited amount of investment in HPS for specific niche applications (e.g., agricultural greenhouses). LPS and MV lamps are no longer being researched or improved in terms of efficacy or other performance attributes, although some consider MH HID lamps to be the next-generation MV lamp. Thus, the efficacy values of commercially available MV, LPS and HPS lamps are not expected to increase in the next 5 to 10 years. MH lamps, and more specifically, ceramic MH lamps are continuing to improve in efficacy as well as light quality, manufacturability and lamp life. Within an HID lamp, the light-producing plasma must be heated to sufficiently high temperatures to achieve high efficiencie

Scholand, Michael

2012-04-01T23:59:59.000Z

75

Survivability of Electronic Compact Fluorescent Lamps  

Science Conference Proceedings (OSTI)

This EPRI Technical Report addresses the fastest growing energy efficient light source8212the electronic compact fluorescent lamp (CFL). Because some of the failure modes for screw-in CFLs are different than those for plug-in CFLs, a cursory review of the difference between the two types of CFLs is provided in the first part of Chapter 2. A broad definition of shortened-life CFLs is also provided in Chapter 2 with an emphasis on revisiting mortality curves, the 10-minute lamp start, other relevant defini...

2008-03-31T23:59:59.000Z

76

Thermal element for maintaining minimum lamp wall temperature in fluorescent fixtures  

DOE Patents (OSTI)

In a lighting fixture including a lamp and a housing, an improvement is disclosed for maintaining a lamp envelope area at a cooler, reduced temperature relative to the enclosed housing ambient. The improvement comprises a thermal element in thermal communication with the housing extending to and springably urging thermal communication with a predetermined area of the lamp envelope surface.

Siminovitch, Michael J. (Richmond, CA)

1992-01-01T23:59:59.000Z

77

Thermal element for maintaining minimum lamp wall temperature in fluorescent fixtures  

DOE Patents (OSTI)

In a lighting fixture including a lamp and a housing, an improvement is disclosed for maintaining a lamp envelope area at a cooler, reduced temperature relative to the enclosed housing ambient. The improvement comprises a thermal element in thermal communication with the housing extending to and springably urging thermal communication with a predetermined area of the lamp envelope surface. 12 figs.

Siminovitch, M.J.

1992-11-10T23:59:59.000Z

78

Max Tech and Beyond: Fluorescent Lamps  

Science Conference Proceedings (OSTI)

Fluorescent lamps are the most widely used artificial light source today, responsible for approximately 70% of the lumens delivered to our living spaces globally. The technology was originally commercialized in the 1930's, and manufacturers have been steadily improving the efficacy of these lamps over the years through modifications to the phosphors, cathodes, fill-gas, operating frequency, tube diameter and other design attributes. The most efficient commercially available fluorescent lamp is the 25 Watt T5 lamp. This lamp operates at 114-116 lumens per watt while also providing good color rendering and more than 20,000 hours of operating life. Industry experts interviewed indicated that while this lamp is the most efficient in the market today, there is still a further 10 to 14% of potential improvements that may be introduced to the market over the next 2 to 5 years. These improvements include further developments in phosphors, fill-gas, cathode coatings and ultraviolet (UV) reflective glass coatings. The commercialization of these technology improvements will combine to bring about efficacy improvements that will push the technology up to a maximum 125 to 130 lumens per watt. One critical issue raised by researchers that may present a barrier to the realization of these improvements is the fact that technology investment in fluorescent lamps is being reduced in order to prioritize research into light emitting diodes (LEDs) and ceramic metal halide high intensity discharge (HID) lamps. Thus, it is uncertain whether these potential efficacy improvements will be developed, patented and commercialized. The emphasis for premium efficacy will continue to focus on T5 lamps, which are expected to continue to be marketed along with the T8 lamp. Industry experts highlighted the fact that an advantage of the T5 lamp is the fact that it is 40% smaller and yet provides an equivalent lumen output to that of a T8 or T12 lamp. Due to its smaller form factor, the T5 lamp contains less material (i.e., glass, fill gas and phosphor), and has a higher luminance, enabling fixtures to take advantage of the smaller lamp size to improve the optics and provide more efficient overall system illuminance. In addition to offering the market a high-quality efficacious light source, another strong value proposition of fluorescent lighting is its long operating life. In today's market, one manufacturer is offering fluorescent lamps that have a rated life of 79,000 hours - which represents 18 years of service at 12 hours per day, 365 days per year. These lamps, operated using a long-life ballast specified by the manufacturer, take advantage of improvements in cathode coatings, fill gas chemistry and pressure to extend service life by a factor of four over conventional fluorescent lamps. It should be noted that this service life is also longer (approximately twice as long) as today's high-quality LED products. The fluorescent market is currently focused on the T5 and T8 lamp diameters, and it is not expected that other diameters would be introduced. Although T8 is a more optimal diameter from an efficacy perspective, the premium efficiency and optimization effort has been focused on T5 lamps because they are 40% smaller than T8, and are designed to operate at a higher temperature using high-frequency electronic ballasts. The T5 lamp offers savings in terms of materials, packaging and shipping, as well as smaller fixtures with improved optical performance. Manufacturers are actively researching improvements in four critical areas that are expected to yield additional efficacy improvements of approximately 10 to 14 percent over the next five years, ultimately achieving approximately 130 lumens per watt by 2015. The active areas of research where these improvements are anticipated include: (1) Improved phosphors which continue to be developed and patented, enabling higher efficacies as well as better color rendering and lumen maintenance; (2) Enhanced fill gas - adjusting proportions of argon, krypton, neon and xenon to optimize performance, while also m

Scholand, Michael

2012-04-01T23:59:59.000Z

79

Incandescent Lighting | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Incandescent Lighting Incandescent Lighting August 16, 2013 - 10:00am Addthis Incandescent lighting is the most common type of lighting used in homes. Incandescent lamps operate...

80

One piece microwave container screens for electrodeless lamps  

DOE Patents (OSTI)

A microwave powered electrodeless lamp includes an improved screen unit having mesh and solid sections with an internal reflector to reflect light into a light-transmitting chamber defined in the lamp microwave cavity by the reflector and the mesh section. A discharge envelope of a bulb is disposed in the light-transmitting chamber. Light emitted from the envelope is prevented by the reflector from entering the cavity portion bounded by the solid section of the screen. Replacing mesh material by solid metal material as part of the screen unit significantly reduces leakage of microwave energy from the lamp. The solid section has multiple compliant fingers defined therein for engaging the periphery of a flange on the waveguide unit so that a hose clamp can easily secure the screen to the assembly. Screen units of this type having different mesh section configurations can be interchanged in the lamp assembly to produce different respective illumination patterns.

Turner, Brian (Myersville, MD); Ury, Michael (Bethesda, MD)

1998-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "lamp sector lighting" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Electronic Radio-Frequency (Electrodeless) Induction Lamps: A Fluorescent Technology  

Science Conference Proceedings (OSTI)

This EPRI Technical Update addresses an expanding energy efficient light source electronic radio-frequency (electrodeless) induction lamps. Business and technical market factors (Chapter 2) use the past and future growth of the CFL market to illustrate the potential for the induction lighting market while emphasizing future technical improvements. Discussion of the importance of utility involvement in helping their customers consider induction lamps for high-efficiency fluorescent applications with long-...

2007-12-20T23:59:59.000Z

82

Energy-efficient compact screw-in fluorescent lamp. Final report  

SciTech Connect

A compact fluorescent lamp has been designed and constructed which can replace an incandescent lamp. The lamp is slightly larger than a standard lamp (8 3/4 in. x 3 1/4 in.), but is designed to fit a majority of portable lamp applications. This version, with a core-coil ballast, results in a system efficacy of 54 lumens per watt, with a light output of more than 1800 lumens. This compares favorably with a 100-watt incandescent (17.5 lumens per watt and 1750 lumens light output). The color temperature of 3000/sup 0/K is compatible with an incandescent lamp (2800/sup 0/K). The color rendition index (CRI) is 84. With a solid-state ballast, the efficacy and light output could be increased by 20% (65 l/w, 2200 lumens) and could provide a direct replacement for a three-way, 150-watt incandescent lamp (15 l/w, 2200 lumens).

Morton, E.W.

1982-11-01T23:59:59.000Z

83

Compatibility testing of fluorescent lamp and ballast systems  

SciTech Connect

The rapid growth in the use of electronic ballasts for fluorescent lighting systems, and the corresponding increase in the number of new products and new manufacturers in the market, has raised a number of questions regarding the compatibility of the lamps and ballasts used in fluorescent systems. Because many of the new products start and operate lamps differently than previous products, the relevant American National Standards Institute requirements may no longer be adequate for addressing compatibility concerns. The impacts on system performance of the newer products of a parametric study designed to test key hypotheses regarding the impact of ballast parameters on fluorescent lamp life. In this study, samples of 4-ft T8 fluorescent lamps were operated on duty cycles of 5 min on and 5 min off, using seven different ballast types. The results of the study indicate which parameters seem to have the biggest effect on lamp life, and can be used in establishing new performance standards for fluorescent systems.

Ji, Y.; Davis, R.; O' Rourke, C.; Chui, E.W.M.

1999-12-01T23:59:59.000Z

84

Advanced Lighting Technologies  

Science Conference Proceedings (OSTI)

This report continues the technical assessment of advanced lighting technologies in the following product areasdimmable light-emitting diode (LED) screw-in replacement lamp, hybrid compact fluorescent lamp/halogen screw-in replacement lamp, replacement recessed can LED downlight, organic LED (OLED) disc, replacement mini high-intensity discharge (HID) lamp and ballast system, and solid-state plasma lighting (miniature HID technology) high-bay fixture. The research in this project helps to demonstrate how...

2011-12-21T23:59:59.000Z

85

New Lighting Technologies  

Science Conference Proceedings (OSTI)

This Electric Power Research Institute (EPRI) technical update continues the technical assessment of advanced lighting technologies in the following product areas—linear LED T8 fluorescent replacements, Edison-based dimmable LED lamps, commercial replacement side-lit LED fixtures, Edison-based reduced-consumption halogen lamps designed to replace 100W incandescent lamps, high bay induction LED lamps, and architectural LED lamps. Many of the products in this year’s report are designed as ...

2012-10-08T23:59:59.000Z

86

Lighting Group: Sources and Ballasts: LED Task Light  

NLE Websites -- All DOE Office Websites (Extended Search)

light The goal of this project is to accelerate the use of energy efficient light emitting diode (LED) technology for general lighting applications by developing a task lamp...

87

LBNL Lighting Research Group  

NLE Websites -- All DOE Office Websites (Extended Search)

LED and ballast berkeley lamp workstation light switch Overview | What's New | Publications | Software | Facilities | People | Contact Us | Links Sources and Ballasts | Light...

88

Vision 2020: Lighting Technology Roadmap | Open Energy Information  

Open Energy Info (EERE)

Vision 2020: Lighting Technology Roadmap Vision 2020: Lighting Technology Roadmap Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Vision 2020: Lighting Technology Roadmap Agency/Company /Organization: United States Department of Energy, LBNL International Energy Studies, International Association of Lighting Designers, International Association of Lighting Management Companies Partner: NAED, NEMA, NEMRA, NECA, NAILD Sector: Energy Focus Area: Energy Efficiency Topics: Market analysis, Technology characterizations Resource Type: Guide/manual Website: www.nrel.gov/docs/fy00osti/27996.pdf References: Vision 2020: Lighting Technology Roadmap[1] Overview "Continued innovation in lamps and other system components, as well as in design practices, have made lighting progressively more effective,

89

A light in the dark sector with a Stueckelberg extension of the standard model  

SciTech Connect

In this work we present a double extension to the Standard Model (SM). One of the extensions is introduced, via minimal coupling, generating a massive Z Prime boson. This enlarged SM is coupled to a dark matter sector through the Stueckelberg mechanism by a A Prime boson. However, the A Prime boson does not interact directly with the SM fermions. In our study, we found that the A Prime is a massless photon-like particle in dark sector. We obtain a new coupling between the usual photon and the dark fermions. Constraints are made on its values.

Dos Santos, A. L.; Hadjimichef, D. [Instituto de Fisica, Universidade Federal do Rio Grande do Sul Caixa Postal 15051, cep 91501-970, Porto Alegre, RS (Brazil)

2013-03-25T23:59:59.000Z

90

Lighting the Night: Technology, Urban Life and the Evolution of Street Lighting [Light in Place  

E-Print Network (OSTI)

Electrical 16. "Highway Lighting by So­ dium Vapor Lamps,"Possibilities of Street: Lighting Improve­ ments," TheLaunches Broad Street Lighting Promotion Campaign," The

Holden, Alfred

1992-01-01T23:59:59.000Z

91

Energy Basics: Fluorescent Lighting  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Fluorescent Lighting Fluorescent lamps use 25%-35% of the energy used by incandescent lamps to provide the same amount of illumination (efficacy of 30-110 lumens per watt). They...

92

Summary of Initial Examination of Lighting-Only Utility Projects in the Federal Sector  

SciTech Connect

This work complements earlier work on an analysis of Federal utility energy projects that implemented excusively lighting upgrades. The objective of this analysis is to better understand the lighting-only projects through determination of the relationship of capital invested and the resulting energy and cost savings, in terms of geographic locale, project size, and potential according to specific lighting technologies and/or control technology implemented.

Solana, Amy E.; Sandusky, William F.; McMordie-Stoughton, Katherine L.

2007-07-26T23:59:59.000Z

93

Lighting retrofit monitoring for the Federal sector-strategies and results at the DOE Forrestal Building  

SciTech Connect

Pacific Northwest Laboratory (PNL), the US Department of Energy (DOE) Federal Energy Management Program (FEMP), and Potomac Electric Power Company (PEPCO) have been conducting short-term monitoring studies at the Forrestal Building, headquarters of the DOE, since 1990. These studies were an integral part of the Shared Energy Savings (SES) lighting retrofit project completed in 1993. The overall goal of the project was to reduce electricity consumption at the Forrestal Building. One objective of the project was to use the building as a model for other federal SES lighting retrofit efforts. A complete short-term monitoring strategy in support of the SES project was developed. The strategy included baseline measurements of electrical consumption, performance measurements of proposed retrofits, and post-retrofit measurements of electricity consumption. Measurements included power consumption, power harmonics, and lighting levels. The results show a 56% reduction in electrical power consumed for lighting, as well as improved power quality and increased lighting levels.

Halverson, M.A.; Schmelzer, J.R.; Keller, J.M.; Stoops, J.L.; Chvala, W.D.

1994-08-01T23:59:59.000Z

94

Inductive tuners for microwave driven discharge lamps  

DOE Patents (OSTI)

An RF powered electrodeless lamp utilizing an inductive tuner in the waveguide which couples the RF power to the lamp cavity, for reducing reflected RF power and causing the lamp to operate efficiently.

Simpson, James E. (Gaithersburg, MD)

1999-01-01T23:59:59.000Z

95

Information Resources: LED Replacement Lamps: Current Performance...  

NLE Websites -- All DOE Office Websites (Extended Search)

incandescent lamps (e.g., A-lamps), and provided an update on ENERGY STAR criteria for LED integral replacement lamps - currently in its second draft. Robert Lingard of Pacific...

96

Demonstration of LED Retrofit Lamps at the Smithsonian American Art Museum, Washington, DC  

Science Conference Proceedings (OSTI)

This report documents observations and results obtained from a lighting demonstration project conducted under the U.S. Department of Energy GATEWAY Solid-State Lighting (SSL) Technology Demonstration Program at the Smithsonain American Art Museum in Washington, DC. LED Lamp samples were tested in the museum workshop, temporarily installed in a gallery for feedback, and ultimately replaced all traditional incandescent lamps in one gallery of modernist art at the American Art Museum and partially replacing lamps in two galleries at the Musesum's Renwick Gallery. This report describes the selection and testing process, technology challenges, perceptions, economics, energy use, and mixed results of usign LED replacement lamps in art galleries housing national treasures.

Miller, Naomi J.; Rosenfeld, Scott M.

2012-06-22T23:59:59.000Z

97

Lamp method and apparatus using multiple reflections  

DOE Patents (OSTI)

An electrodeless microwave discharge lamp includes an envelope with a discharge forming fill disposed therein which emits light, the fill being capable of absorbing light at one wavelength and re-emitting the absorbed light at a different wavelength, the light emitted from the fill having a first spectral power distribution in the absence of reflection of light back into the fill, a source of microwave energy coupled to the fill to excite the fill and cause the fill to emit light, and a reflector disposed within the microwave cavity and configured to reflect at least some of the light emitted by the fill back into the fill while allowing some light to exit, the exiting light having a second spectral power distribution with proportionately more light in the visible region as compared to the first spectral power distribution, wherein the light re-emitted by the fill is shifted in wavelength with respect to the absorbed light and the magnitude of the shift is in relation to an effective optical path length.

MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD)

2001-01-01T23:59:59.000Z

98

Information Resources: LED Replacements for Linear Fluorescent Lamps  

NLE Websites -- All DOE Office Websites (Extended Search)

Replacements for Linear Fluorescent Lamps Webcast Replacements for Linear Fluorescent Lamps Webcast In this June 20, 2011 webcast on LED products marketed as replacements for linear fluorescent lamps, Jason Tuenge of the Pacific Northwest National Laboratory (PNNL) discussed current Lighting Facts-listed products as well as products evaluated in the latest CALiPER reports. Eric Richman, also of PNNL, reported on a recently completed GATEWAY demonstration project, in which LED and fluorescent lamps were installed in a variety of recessed troffer luminaires for comparison in an office environment. The presentation concluded with a discussion of specifications listed in a newly updated technology fact sheet. View presentation slides View the text-alternative version View the webcast (WMV 16 MB) Download Windows Media Player

99

A Demonstration of LED Lighting for Saving Energy in the Poultry Sector  

DOE Green Energy (OSTI)

The Lumina Project and Lighting Africa conducted a full-scale field test involving a switch from kerosene to solar-LED lighting for commercial broiler chicken production at an off-grid farm in Kenya. The test achieved lower operating costs, produced substantially more light, improved the working environment, and had no adverse effect on yields. A strategy using conventional solar-fluorescent lighting also achieved comparable yields, but entailed a six-fold higher capital cost and significantly higher recurring battery replacement costs. Thanks to higher energy and optical efficiencies, the LED system provided approximately twice the illumination to the chicken-production area and yet drew less than half the power.At the study farm, 3000 chickens were grown in each of three identical houses under kerosene, fluorescent, and LED lighting configurations. Under baseline conditions, a yearly expenditure of 1,200 USD is required to illuminate the three houses with kerosene. The LED system eliminates this fuel use and expense with a corresponding simple payback time of 1.5 years, while the solar-fluorescent system has a payback time of 9.3 years. The corresponding reduction in fuel expenditure in both cases represents a 15percent increase in after-tax net income (revenues minus expenses) across the entire business operation. The differential cost-effectiveness between the LED and fluorescent systems would be substantially greater if the fluorescent system were upsized to provide the same light as the LED system. Providing light with the fluorescent or LED systems is also far more economical than connecting to the grid in this case. The estimated grid-connection cost at this facility is 1.7 million Kenya Schillings (approximately 21,250 USD), which is nearly six-times the cost of the fluorescent system and 35-times the cost of the LED system.The LED system also confers various non-energy benefits. The relative uniformity of LED lighting, compared to the fluorescent or kerosene lighting, reduced crowding which in turn created a less stressful environment for the chickens. The far higher levels of illumination also created a better environment for the workers, while eliminating the time required for obtaining fuel and maintaining kerosene lanterns. An additional advantage of the LED system relative to the solar fluorescent system was that the former does not require a skilled technician to carry out the installation. The portable LED system lighting layout is also more easily adjusted than that of the hardwired fluorescent systems. Furthermore, switching to the LED system avoids over one metric ton of carbon dioxide emissions per house on an annual basis compared to kerosene. There is high potential for replication of this particular LED lighting strategy in the developing world. In order to estimate the scale of kerosene use and the potential for savings, more information is needed on the numbers of chickens produced off-grid, as well as lighting uses for other categories of poultry production (egg layers, indigenous broilers ). Our discovery that weight gain did not slow in the solar-fluorescent house after it experienced extended lighting outages beginning on day 14 of the 35-day study suggests that conventional farming practices in Kenyan broiler operations may call for more hours of lighting than is needed to achieve least-cost production.

Tracy, Jennifer; Mills, Evan

2010-11-06T23:59:59.000Z

100

Performance of T12 and T8 Fluorescent Lamps and Troffers and LED Linear Replacement Lamps CALiPER Benchmark Report  

Science Conference Proceedings (OSTI)

The Department of Energy (DOE) Commercially Available LED Product Evaluation and Reporting (CALiPER) Program was established in 2006 to investigate the performance of light-emitting diode (LED) based luminaires and replacement lamps. To help users better compare LED products with conventional lighting technologies, CALiPER has also performed benchmark research and testing of traditional (i.e., non-LED) lamps and fixtures. This benchmark report addresses standard 4-foot fluorescent lamps (i.e., T12 and T8) and the 2-foot by 4-foot recessed troffers in which they are commonly used. This report also examines available LED replacements for T12 and T8 fluorescent lamps, and their application in fluorescent troffers. The construction and operation of linear fluorescent lamps and troffers are discussed, as well as fluorescent lamp and fixture performance, based on manufacturer data and CALiPER benchmark testing. In addition, the report describes LED replacements for linear fluorescent lamps, and compares their bare lamp and in situ performance with fluorescent benchmarks on a range of standard lighting measures, including power usage, light output and distribution, efficacy, correlated color temperature, and the color rendering index. Potential performance and application issues indicated by CALiPER testing results are also examined.

Myer, Michael; Paget, Maria L.; Lingard, Robert D.

2009-01-16T23:59:59.000Z

Note: This page contains sample records for the topic "lamp sector lighting" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Ningbo Liaoyuan Lighting Co | Open Energy Information  

Open Energy Info (EERE)

Liaoyuan Lighting Co Liaoyuan Lighting Co Jump to: navigation, search Name Ningbo Liaoyuan Lighting Co Place Yuyao, Zhejiang Province, China Zip 315408 Sector Solar, Wind energy Product Engaged in outdoor LED lighting manufacture and design including street lamps and solar/wind hybrid street lamps. Coordinates 30.047501°, 121.151222° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":30.047501,"lon":121.151222,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

102

Reading Municipal Light Department - Business Lighting Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Reading Municipal Light Department - Business Lighting Rebate Reading Municipal Light Department - Business Lighting Rebate Program Reading Municipal Light Department - Business Lighting Rebate Program < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Schools State Government Savings Category Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Commercial Customers: $10,000 per calendar year Municipal Customers: $15,000 per calendar year Program Info State Massachusetts Program Type Utility Rebate Program Rebate Amount T-8/T-5 Lamp with Electronic Ballasts: $11 - $35/fixture Interior High Output Lamp with Electronic Ballasts: $100/fixture De-lamping: $4 - $9/lamp Lighting Sensors: $20/sensor LED Exit Signs: $20/fixture Provider Incentive Programs

103

Transportation Energy Futures Series: Potential for Energy Efficiency Improvement Beyond the Light-Duty-Vehicle Sector  

Science Conference Proceedings (OSTI)

Considerable research has focused on energy efficiency and fuel substitution options for light-duty vehicles, while much less attention has been given to medium- and heavy-duty trucks, buses, aircraft, marine vessels, trains, pipeline, and off-road equipment. This report brings together the salient findings from an extensive review of literature on future energy efficiency options for these non-light-duty modes. Projected activity increases to 2050 are combined with forecasts of overall fuel efficiency improvement potential to estimate the future total petroleum and greenhouse gas (GHG) emissions relative to current levels. This is one of a series of reports produced as a result of the Transportation Energy Futures (TEF) project, a Department of Energy-sponsored multi-agency project initiated to pinpoint underexplored strategies for abating GHGs and reducing petroleum dependence related to transportation.

Vyas, A. D.; Patel, D. M.; Bertram, K. M.

2013-03-01T23:59:59.000Z

104

Lighting Options for Homes.  

SciTech Connect

This report covers many aspects of various lighting options for homes. Types of light sources described include natural light, artificial light, incandescent lamps, fluorescent lamps, and high intensity discharge lamps. A light source selection guide gives the physical characteristics of these, design considerations, and common applications. Color, strategies for efficient lighting, and types of lighting are discussed. There is one section giving tips for various situations in specific rooms. Rooms and types of fixtures are shown on a matrix with watts saved by using the recommended type lighting for that room and room location. A major emphasis of this report is saving energy by utilizing the most suitable, recommended lighting option. (BN)

Baker, W.S.

1991-04-01T23:59:59.000Z

105

Background Overview of Solid-State Lighting  

NLE Websites -- All DOE Office Websites (Extended Search)

light sources Dramatic changes are unfolding in lighting technology. Semiconductor light-emitting diodes (LEDs), until recently used mainly as simple indicator lamps in...

106

The effects of supply harmonics on the performance of compact fluorescent lamps  

SciTech Connect

This paper describes a performance evaluation of ten compact fluorescent lighting systems operated with sinusoidal and distorted voltage waveform conditions. The lamps were either provided with an electronic ballast, a magnetic core ballast or a magnetic core ballast with a power factor correction circuit. The test results show that the electrical performance of the compact fluorescent lamps for both sinusoidal and distorted voltage waveform operation is related to the different types of ballast used. The cost of operation of these compact fluorescent lamps was calculated and compared to the cost of a conventional 60 W incandescent lamp.

Arseneau, R.; Ouellette, M.

1993-04-01T23:59:59.000Z

107

NIST Highlight about spectrally tunable lighting facility  

Science Conference Proceedings (OSTI)

... white light produced by fluorescent lamps? Which spectral combination gives the best color quality and energy efficiency? ...

2012-10-02T23:59:59.000Z

108

New and Underutilized Technology: Interior LED/Solid State Lighting |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interior LED/Solid State Lighting Interior LED/Solid State Lighting New and Underutilized Technology: Interior LED/Solid State Lighting October 4, 2013 - 4:53pm Addthis The following information outlines key deployment considerations for interior LED/solid state lighting within the Federal sector. Benefits Interior LED retrofits are currently viable for down lights, track lighting, sconces, and both line and low voltage task lighting. Replacements for incandescent A-lamps have also been improving rapidly. Replacements for fluorescent tube lighting may be viable for high-cost maintenance areas. Application Interior LED/solid state lighting is a rapidly improving technology currently most applicable for down lights, track lights, task lighting, accenting, high ceiling, and high cost maintenance areas.

109

Outlaw lighting  

SciTech Connect

Demand-side management programs by utilities and the federal government`s Green Lights program have made significant inroads in promoting energy-efficient lighting. But the Energy Policy Act now prohibits certain types of lighting. This article provides analysis to help architects determine new lamp performance compared with older lighting products.

Bryan, H.

1994-12-01T23:59:59.000Z

110

Magical Mystery Devices or Not: How do LED Lamps and Luminaires Really Measure-Up?  

SciTech Connect

Solid-state lighting products for general lighting applications are now gaining a market presence, and more and more people are asking, “Which of these are ‘good’ products? Do they perform as claimed? How do they compare? Light Emitting Diodes (LEDs) differ from other light sources enough to require new procedures for measuring their performance and comparing to other lighting options, so both manufacturers and buyers are facing a learning curve. The energy-efficiency community has traditionally compared light sources based on system efficacy: rated lamp lumens divided by power into the system. This doesn’t work for LEDs because there are no standard LED “lamp” packages and no lamp ratings, and because LED performance depends heavily on thermal, electrical, and optical design of complete lighting unit or ‘luminaire’. Luminaire efficacy is the preferred metric for LEDs because it measures the net light output from the luminaire divided by power into the system.

Paget, Maria L.; McCullough, Jeffrey J.; Steward, Heidi E.

2008-08-15T23:59:59.000Z

111

Issues, Models and Solutions for Triac Modulated Phase Dimming of LED Lamps  

E-Print Network (OSTI)

/a 30 lumens 0.1 Incandescent Bulb 15 W 225 lumens 15 Fluorescent Tube Lamp 10 W 500 lumens 50 White LED bulbs, and fluorescent lights, produce light that is radiated in all directions, LEDs produce a focused especially on the potential of white LED lights, which are an important and newly emerging lighting

Lehman, Brad

112

Arnold Schwarzenegger LIGHTING RESEARCH PROGRAM  

E-Print Network (OSTI)

Project Summaries ELEMENT 2: ADVANCE LIGHTING TECHNOLOGIES PROJECT 2.1 LIGHT EMITTING DIODE (LED light emitting diodes (LED) technology for general lighting applications by developing a task lamp

113

Phosphors for LED lamps  

DOE Patents (OSTI)

A phosphor, a phosphor blend including the phosphor, a phosphor prepared by a process, and a lighting apparatus including the phosphor blend are disclosed. The phosphor has the formula (Ca.sub.1-p-qCe.sub.pK.sub.q).sub.xSc.sub.y(Si.sub.1-rGa.sub.r).sub.zO.su- b.12+.delta. or derived from a process followed using disclosed amounts of reactants. In the formula, (0

Murphy, James Edward; Manepalli, Satya Kishore; Kumar, Prasanth Nammalwar

2013-08-13T23:59:59.000Z

114

Selecting effective fluorescent lamp and ballast for retrofit in the continental United States. Final report  

SciTech Connect

Electrical lighting is a major contributor to daytime peak energy demand, accounting for about 30 percent of total electricity consumption in most Army facilities. Some of this energy may be wasted because many existing lighting systems at Army Installations use outmoded technologies. While recent technology has improved the energy efficiency of all lighting systems, fluorescent lighting-the most widely used interior building lighting-has shown the greatest efficiency gains. Retrofits using high-efficiency fluorescent lamps and ballasts can yield significant operating cost savings. High-efficiency fluorescent lighting systems are widely available, but current information on their performance characteristics is highly technical and not easily accessible to Army facility managers considering retrofit options. This report provides a single, accessible source that summarizes fluorescent lamp and ballast performance characteristics and outlines selection procedures. Fluorescent lamp, Retrofit, Ballast, Lighting. Energy conservation.

Taylor, W.R.

1993-08-01T23:59:59.000Z

115

Flicker Performance of Modern Lighting Technologies including Impacts of Dimmers  

Science Conference Proceedings (OSTI)

The existing industry standards on flicker measurement and assessment are based on the response of general purpose incandescent lamps. However, worldwide these lamps are being replaced with more energy efficient lamps including Compact Fluorescent Lamps (CFLs) and Light emitting Diode (LED) lamps. In order to keep the flicker standards relevant, the industry standard bodies on the subject are in need of the evidence that compares the flicker performance of new lighting ...

2012-12-12T23:59:59.000Z

116

Lighting Research Group: Facilities: Integrating Sphere  

NLE Websites -- All DOE Office Websites (Extended Search)

Integrating Sphere Integrating Sphere integrating sphere Integrating Sphere Gonio-photometer | Integrating sphere | Power analyzer | Spectro-radiometer The integrating sphere is used to quickly measure the total light output of a lamp. The lamp being tested is placed in the center of the integrating sphere. At one side of the sphere is a light meter which measures the light output of the lamp. Between the lamp and the light meter there is a baffle to prevent the meter from seeing any direct light from the lamp. The inside of the sphere (including the baffle) is coated with a very white paint that reflects all wavelengths equally. This allows us to get very accurate measurements. The light from the lamp bounces around the sphere until it reaches the light meter. It is important that nothing else is in the sphere besides the lamp and the

117

Integrated starting and running amalgam assembly for an electrodeless fluorescent lamp  

DOE Patents (OSTI)

An integrated starting and running amalgam assembly for an electrodeless SEF fluorescent lamp includes a wire mesh amalgam support constructed to jointly optimize positions of a starting amalgam and a running amalgam in the lamp, thereby optimizing mercury vapor pressure in the lamp during both starting and steady-state operation in order to rapidly achieve and maintain high light output. The wire mesh amalgam support is constructed to support the starting amalgam toward one end thereof and the running amalgam toward the other end thereof, and the wire mesh is rolled for friction-fitting within the exhaust tube of the lamp. The positions of the starting and running amalgams on the wire mesh are jointly optimized such that high light output is achieved quickly and maintained, while avoiding any significant reduction in light output between starting and running operation.

Borowiec, Joseph Christopher (Schenectady, NY); Cocoma, John Paul (Clifton Park, NY); Roberts, Victor David (Burnt Hills, NY)

1998-01-01T23:59:59.000Z

118

Illuminating the Pecking Order in Off-Grid Lighting: A Demonstration of LED Lighting for Saving Energy in the Poultry Sector  

E-Print Network (OSTI)

each of the three systems. Lighting System Kerosene Solar-opened and all available lighting points in use—we measuredin comparison to the other lighting systems. There is

Tracy, Jennifer

2012-01-01T23:59:59.000Z

119

Building Technologies Office: Solid-State Lighting  

NLE Websites -- All DOE Office Websites (Extended Search)

of two pages from the CALiPER Snapshot Report on A lamps. CALiPER Product Snapshot on LED Light Bulbs Report on the current state of the market for LED A lamp and omnidirectional...

120

Fluorescent Lighting | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Fluorescent Lighting Fluorescent Lighting Fluorescent Lighting October 17, 2013 - 5:44pm Addthis Fluorescent Lighting Fluorescent Lighting Fluorescent lamps use 25%-35% of the energy used by incandescent products to provide a similar amount of light. They also last about 10 times longer (7,000-24,000 hours). The two general types of fluorescent lamps are: Compact fluorescent lamps (CFLs) -- commonly found with integral ballasts and screw bases, these are popular lamps often used in household fixtures Fluorescent tube and circline lamps -- typically used for task lighting such as garages and under cabinet fixtures, and for lighting large areas in commercial buildings. CFLs CFLs combine the energy efficiency of fluorescent lighting with the convenience and popularity of incandescent fixtures. CFLs fit most fixtures

Note: This page contains sample records for the topic "lamp sector lighting" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

New Energy-Saving Fiber Optic Lighting System Lights Up Public Spaces  

Energy.gov (U.S. Department of Energy (DOE))

Case study covering Energy Focus, Inc. and its lighting technology that delivers light comparable to conventional lamps while using significantly less energy per lumen.

122

New Light Sources for Tomorrow's Lighting Designs  

E-Print Network (OSTI)

The lighting industry is driven to provide light sources and lighting systems that, when properly applied, will produce a suitable luminous environment in which to perform a specified task. Tasks may include everything from office work, manufacturing and inspection to viewing priceless art objects, selecting the right chair for your living room, and deciding which produce item to select for tonight's dinner. While energy efficiency is a major consideration in any new lighting system design, the sacrifice of lighting quality may cost more in terms of lost productivity and user dissatisfaction than can ever be saved on that monthly energy bill. During the past several years, many new light sources have been developed and introduced. These product introductions have not been limited to anyone lamp type, but instead may be found in filament, fluorescent and high intensity discharge lamp families. Manufacturers of light sources have two basic goals for new product development. These goals are high efficiency lighting and improved color rendering properties. High efficiency lighting may take the form of either increasing lamp efficiency (lumens of light delivered per watt of power consumed) or decreasing lamp size, thus making a more easily controlled light source that places light where it is needed. The manufacturer's second goal is to produce lamps that render colors accurately while maintaining high efficiency. This paper will discuss new introductions in light sources and lighting systems and how they may impact the design of luminous environments of the future.

Krailo, D. A.

1986-06-01T23:59:59.000Z

123

New and Underutilized Technology: Efficient High Bay Fluorescent Lighting |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Efficient High Bay Fluorescent Efficient High Bay Fluorescent Lighting New and Underutilized Technology: Efficient High Bay Fluorescent Lighting October 7, 2013 - 8:54am Addthis The following information outlines key deployment considerations for efficient high bay fluorescent lighting within the Federal sector. Benefits Efficient high bay fluorescent lighting can include either T5 or T8 fluorescent lighting systems for high-bay applications currently using metal halide fixtures. Fluorescent fixtures offer better light distribution, better light maintenance over the life of the lamp, improved color quality, and on-off control (re-strike time) with lower energy consumption. Application Efficient high bay fluorescent lighting is applicable for facilities containing high bay areas. Key Factors for Deployment

124

Demonstration of LED Retrofit Lamps at the Jordan Schnitzer Museum of Art  

SciTech Connect

The Jordan Schnitzer Museum of Art in Eugene, Oregon, houses a remarkable permanent collection of Asian art and antiquities, modern art, and sculpture, and also hosts traveling exhibitions. In the winter and spring of 2011, a series of digital photographs by artist Chris Jordan, titled "Running the Numbers," was exhibited in the Coeta and Donald Barker Special Exhibitions Gallery. These works graphically illustrate waste (energy, money, health, consumer objects, etc.) in contemporary culture. The Bonneville Power Administration and the Eugene Water and Electricity Board provided a set of Cree 12W light-emitting diode (LED) PAR38 replacement lamps (Cree LRP38) for the museum to test for accent lighting in lieu of their standard Sylvania 90W PAR38 130V Narrow Flood lamps (which draw 78.9W at 120V). At the same time, the museum tested LED replacement lamps from three other manufacturers, and chose the Cree lamp as the most versatile and most appropriate color product for this exhibit. The lamps were installed for the opening of the show in January 2011. This report describes the process for the demonstration, the energy and economic results, and results of a survey of the museum staff and gallery visitors on four similar clusters of art lighted separately by four PAR38 lamps.

Miller, Naomi J.

2011-09-01T23:59:59.000Z

125

Lighting Research Group: Facilities  

NLE Websites -- All DOE Office Websites (Extended Search)

Facilities Facilities Lighting Research Facilities at LBNL gonio-photometer Gonio-photometer We use this device to measure the intensity and direction of the light from a lamp or fixture. integrating sphere Integrating sphere This instrument allows us to get a fast and accurate measurement of the total light output of a lamp. We are not able to determine the direction of the light, only the intensity. power analyzer Power analyzer We use our power analyzer with the lamps in the gonio-photometer to measure input power, harmonic distortion, power factor, and many other signals that tell us how well a lamp is performing. spectro-radiometer Spectro-radiometer This device measures not only the intensity of a light source but also the intensity of the light at each wavelength.

126

Lighting Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

Purple LED lamp Purple LED lamp Lighting Systems Lighting research is aimed at improving the energy efficiency of lighting systems in buildings and homes across the nation. The goal is to reduce lighting energy consumption by 50% over twenty years by improving the efficiency of light sources, and controlling and delivering illumination so that it is available, where and when needed, and at the required intensity. Research falls into four main areas: Sources and Ballasts, Light Distribution Systems, Controls and Communications, and Human Factors. Contacts Francis Rubinstein FMRubinstein@lbl.gov (510) 486-4096 Links Lighting Research Group Batteries and Fuel Cells Buildings Energy Efficiency Applications Commercial Buildings Cool Roofs and Heat Islands Demand Response Energy Efficiency Program and Market Trends

127

DuraLamp USA: Order (2010-CE-0912)  

Energy.gov (U.S. Department of Energy (DOE))

DOE ordered DuraLamp USA, Inc. to pay a $2,500 civil penalty after finding DuraLamp USA had failed to certify that model PAR 30, an incandescent reflector lamp, complies with the applicable energy conservation standards.

128

Solid-state lamp with integral occupancy sensor  

E-Print Network (OSTI)

Previous work demonstrated a retrofit proximity detector for fluorescent lamps using the lamp's own stray electric fields. This paper extends the retrofit sensor system to a solid-state (LED) lamp. The design and implementation ...

Cooley, John J.

129

ComEd - Business Instant Lighting Discounts Program (Illinois...  

Open Energy Info (EERE)

Industrial, Multi-Family Residential, Private Schools Eligible Technologies Lighting, LED Lighting, Reduced Wattage Metal Halide Lamps, LED Trim Kits, Screw-In CFL's Active...

130

Illuminating the Pecking Order in Off-Grid Lighting: A Demonstration of LED Lighting for Saving Energy in the Poultry Sector  

Science Conference Proceedings (OSTI)

The Lumina Project and Lighting Africa conducted a full-scale field test involving a switch from kerosene to solar-LED lighting for commercial broiler chicken production at an off-grid farm in Kenya. The test achieved lower operating costs, produced substantially more light, improved the working environment, and had no adverse effect on yields. A strategy using conventional solar-fluorescent lighting also achieved comparable yields, but entailed a six-fold higher capital cost and significantly higher recurring battery replacement costs. Thanks to higher energy and optical efficiencies, the LED system provided approximately twice the illumination to the chicken-production area and yet drew less than half the power.At the study farm, 3000 chickens were grown in each of three identical houses under kerosene, fluorescent, and LED lighting configurations. Under baseline conditions, a yearly expenditure of 1,200 USD is required to illuminate the three houses with kerosene. The LED system eliminates this fuel use and expense with a corresponding simple payback time of 1.5 years, while the solar-fluorescent system has a payback time of 9.3 years. The corresponding reduction in fuel expenditure in both cases represents a 15percent increase in after-tax net income (revenues minus expenses) across the entire business operation. The differential cost-effectiveness between the LED and fluorescent systems would be substantially greater if the fluorescent system were upsized to provide the same light as the LED system. Providing light with the fluorescent or LED systems is also far more economical than connecting to the grid in this case. The estimated grid-connection cost at this facility is 1.7 million Kenya Schillings (approximately 21,250 USD), which is nearly six-times the cost of the fluorescent system and 35-times the cost of the LED system.The LED system also confers various non-energy benefits. The relative uniformity of LED lighting, compared to the fluorescent or kerosene lighting, reduced crowding which in turn created a less stressful environment for the chickens. The far higher levels of illumination also created a better environment for the workers, while eliminating the time required for obtaining fuel and maintaining kerosene lanterns. An additional advantage of the LED system relative to the solar fluorescent system was that the former does not require a skilled technician to carry out the installation. The portable LED system lighting layout is also more easily adjusted than that of the hardwired fluorescent systems. Furthermore, switching to the LED system avoids over one metric ton of carbon dioxide emissions per house on an annual basis compared to kerosene. There is high potential for replication of this particular LED lighting strategy in the developing world. In order to estimate the scale of kerosene use and the potential for savings, more information is needed on the numbers of chickens produced off-grid, as well as lighting uses for other categories of poultry production (egg layers, indigenous broilers ). Our discovery that weight gain did not slow in the solar-fluorescent house after it experienced extended lighting outages beginning on day 14 of the 35-day study suggests that conventional farming practices in Kenyan broiler operations may call for more hours of lighting than is needed to achieve least-cost production.

Tracy, Jennifer; Mills, Evan

2010-11-06T23:59:59.000Z

131

Solid-State Lighting: LED Replacements for Linear Fluorescent...  

NLE Websites -- All DOE Office Websites (Extended Search)

LED Replacements for Linear Fluorescent Lamps Webcast to someone by E-mail Share Solid-State Lighting: LED Replacements for Linear Fluorescent Lamps Webcast on Facebook Tweet about...

132

Lamp system for uniform semiconductor wafer heating  

SciTech Connect

A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.

Zapata, Luis E. (Livermore, CA); Hackel, Lloyd (Livermore, CA)

2001-01-01T23:59:59.000Z

133

Efficient Driver for Dimmable White LED Lighting.  

E-Print Network (OSTI)

??A high efficiency driver circuit is proposed for Light Emitting Diode (LED) lamps with dimming feature. The current regulation is accomplished by processing partial power… (more)

Yang, Wen-ching

2011-01-01T23:59:59.000Z

134

LED lamp power management system and method  

DOE Patents (OSTI)

An LED lamp power management system and method including an LED lamp having an LED controller 58; a plurality of LED channels 60 operably connected to the LED controller 58, each of the plurality of LED channels 60 having a channel switch 62 in series with at least one shunted LED circuit 83, the shunted LED circuit 83 having a shunt switch 68 in parallel with an LED source 80. The LED controller 58 reduces power loss in one of the channel switch 62 and the shunt switch 68 when LED lamp electronics power loss (P.sub.loss) exceeds an LED lamp electronics power loss limit (P.sub.lim); and each of the channel switches 62 receives a channel switch control signal 63 from the LED controller 58 and each of the shunt switches 68 receives a shunt switch control signal 69 from the LED controller 58.

Gaines, James; Clauberg, Bernd; Van Erp, Josephus A. M.

2013-03-19T23:59:59.000Z

135

Lighting.  

SciTech Connect

Since lighting accounts for about one-third of the energy used in commercial buildings, there is opportunity to conserve. There are two ways to reduce lighting energy use: modify lighting systems so that they used less electricity and/or reduce the number of hours the lights are used. This booklet presents a number of ways to do both. Topics covered include: reassessing lighting levels, reducing lighting levels, increasing bulb & fixture efficiency, using controls to regulate lighting, and taking advantage of daylight.

United States. Bonneville Power Administration.

1992-09-01T23:59:59.000Z

136

Long-Term Performance of Screwbase Compact Fluorescent Lamps  

Science Conference Proceedings (OSTI)

The packaging material for compact fluorescent lamps normally includes some claim regarding expected lamp lifetime. This claimed lifetime is generally not obtained through rigorous testing. This study shows how different operating cycles, components, and lamp and ballast designs affect screwbase compact fluorescent lamp (SCFL) life.

2000-04-11T23:59:59.000Z

137

Evaluation of Lighting and Lighting Control Technologies  

Science Conference Proceedings (OSTI)

Energy efficient lighting and lighting controls have been a means to significant energy savings for many facilities around the world. Advances in lighting sources often allow for the conservation of quality of light while providing more flexibility in the control of light. Additionally, advances in core technologies within the lighting marketplace regularly lead to the introduction of new lamps, fixtures and controls.  With the rapid introduction of new products and designs, it is important to ...

2013-11-15T23:59:59.000Z

138

High frequency inductive lamp and power oscillator  

DOE Patents (OSTI)

A high frequency inductively coupled electrodeless lamp includes an excitation coil with an effective electrical length which is less than one half wavelength of a driving frequency applied thereto, preferably much less. The driving frequency may be greater than 100 MHz and is preferably as high as 915 MHz. Preferably, the excitation coil is configured as a non-helical, semi-cylindrical conductive surface having less than one turn, in the general shape of a wedding ring. At high frequencies, the current in the coil forms two loops which are spaced apart and parallel to each other. Configured appropriately, the coil approximates a Helmholtz configuration. The lamp preferably utilizes an bulb encased in a reflective ceramic cup with a pre-formed aperture defined therethrough. The ceramic cup may include structural features to aid in alignment and/or a flanged face to aid in thermal management. The lamp head is preferably an integrated lamp head comprising a metal matrix composite surrounding an insulating ceramic with the excitation integrally formed on the ceramic. A novel solid-state oscillator preferably provides RF power to the lamp. The oscillator is a single active element device capable of providing over 70 watts of power at over 70% efficiency. Various control circuits may be employed to match the driving frequency of the oscillator to a plurality of tuning states of the lamp.

MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD); Dolan, James T. (Frederick, MD); Kirkpatrick, Douglas A. (Great Falls, VA); Leng, Yongzhang (Damascus, MD)

2000-01-01T23:59:59.000Z

139

Building Technologies Office: Fluorescent and Incandescent Lamps Public  

NLE Websites -- All DOE Office Websites (Extended Search)

Fluorescent and Fluorescent and Incandescent Lamps Public Meeting to someone by E-mail Share Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Facebook Tweet about Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Twitter Bookmark Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Google Bookmark Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Delicious Rank Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Digg Find More places to share Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on AddThis.com... About Standards & Test Procedures Implementation, Certification & Enforcement

140

Energy Basics: High-Intensity Discharge Lighting  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

and longest service life of any lighting type. It can save 75%-90% of lighting energy when it replaces incandescent lighting. HID lamps use an electric arc to produce...

Note: This page contains sample records for the topic "lamp sector lighting" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Conservation potential of compact fluorescent lamps in India and Brazil  

SciTech Connect

We evaluate the conservation potential of compact fluorescent lamps (CFLs) for managing the rapidly increasing electrical energy and peak demand in India and Brazil. Using very conservative assumptions, we find that the cost of conserved energy using 16 W CFLs is 4 and 6 times less than the long range marginal cost of electricity for the two countries. The cost of avoided peak installed capacity is 6 and 9.5 times less than the cost of new installed capacity for India and Brazil. The analysis is undertaken from the three separate perspectives of the national economies, the consumers, and the utilities. We find that because residential electricity is subsidized, the consumers have little or no incentive to purchase and install the CFLs, unless they too are subsidized. However, the benefits of CFL installation to the utility are so large that subsidizing them is a paying proposition for the utility are so large that subsidizing them is a paying proposition for the utility in almost all cases. As an illustration of a gradual introduction strategy for CFLs, we calculate a scenario where national savings of the order of US $1.2 million per day for India and US $2.5 million per day for Brazil are reached in 10 years by a small and gradual transfer of subsidy from residential electricity to CFLs. We then explore the barriers to immediate large scale introduction of these lamps in the two countries. Specific technical and marketing problems are identified and discussed, which would require solution before such an introduction can be attempted. Lastly, we discuss the range of policy instruments, in addition to a subsidy scheme, that can be used for promoting the diffusion of these lamps in the domestic and commercial sector. 47 refs., 15 figs., 2 tabs.

Gadgil, A.; Martino Jannuzzi, G. de (Lawrence Berkeley Lab., CA (USA); Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia)

1989-07-01T23:59:59.000Z

142

Lighting  

Energy.gov (U.S. Department of Energy (DOE))

There are many different types of artificial lights, all of which have different applications and uses. Types of lighting include:

143

High frequency inductive lamp and power oscillator  

DOE Patents (OSTI)

A high frequency inductively coupled electrodeless lamp includes an excitation coil with an effective electrical length which is less than one half wavelength of a driving frequency applied thereto, preferably much less. The driving frequency may be greater than 100 MHz and is preferably as high as 915 MHz. Preferably, the excitation coil is configured as a non-helical, semi-cylindrical conductive surface having less than one turn, in the general shape of a wedding ring. At high frequencies, the current in the coil forms two loops which are spaced apart and parallel to each other. Configured appropriately, the coil approximates a Helmholtz configuration. The lamp preferably utilizes an bulb encased in a reflective ceramic cup with a pre-formed aperture defined therethrough. The ceramic cup may include structural features to aid in alignment and I or a flanged face to aid in thermal management. The lamp head is preferably an integrated lamp head comprising a metal matrix composite surrounding an insulating ceramic with the excitation integrally formed on the ceramic. A novel solid-state oscillator preferably provides RF power to the lamp. The oscillator is a single active element device capable of providing over 70 watts of power at over 70% efficiency. Various control circuits may be employed to adjust the driving frequency of the oscillator.

MacLennan, Donald A. (Gaithersburg, MD); Dymond, Jr., Lauren E. (North Potomac, MD); Gitsevich, Aleksandr (Montgomery Village, MD); Grimm, William G. (Silver Spring, MD); Kipling, Kent (Gaithersburg, MD); Kirkpatrick, Douglas A. (Great Falls, VA); Ola, Samuel A. (Silver Spring, MD); Simpson, James E. (Gaithersburg, MD); Trimble, William C. (Columbia, MD); Tsai, Peter (Olney, MD); Turner, Brian P. (Damascus, MD)

2001-01-01T23:59:59.000Z

144

Avista Utilities (Electric) - Commercial Lighting Energy Efficiency...  

Open Energy Info (EERE)

Applicable Sector Commercial Eligible Technologies Lighting, Lighting ControlsSensors, LED Lighting Active Incentive Yes Implementing Sector Utility Energy Category Energy...

145

Energy Cost Calculator for Compact Fluorescent Lamps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Compact Fluorescent Lamps Compact Fluorescent Lamps Energy Cost Calculator for Compact Fluorescent Lamps October 8, 2013 - 2:18pm Addthis This tool calculates the payback period for your calc retrofit project. Modify the default values to suit your project requirements. Existing incandescent lamp wattage Watts Incandescent lamp cost dollars Incandescent lamp life 1000 hours calc wattage Watts calc cost dollars calc life (6000 hours for moderate use, 10000 hours for high use) 8000 hours Number of lamps in retrofit project Hours operating per week hours Average cost of electricity 0.06 $/kWh Relamper labor costs $/hr Time taken to retrofit all lamps in this project min Time taken to relamp one lamp min Type of Relamping Practiced: Group Relamping: Calculate Simple Payback Period months

146

Energy and lighting design  

SciTech Connect

Energy conserving practices in providing lighting for today's buildings are examined in this second of a two-part presentation. Discussion on light source characteristics, ballast characteristics for gaseous discharge lamps, quality and the cost of lighting, and equivalent sphere illumination are included.

Helms, R.N.

1979-12-01T23:59:59.000Z

147

Types of Lighting in Commercial Buildings - Lighting Characteristics  

U.S. Energy Information Administration (EIA) Indexed Site

Characteristics of Lighting Types Characteristics of Lighting Types Efficacy Efficacy is the amount of light produced per unit of energy consumed, expressed in lumens per watt (lm/W). Lamps with a higher efficacy value are more energy efficient. Average Rated Life The average rated life of a particular type of lamp is defined by the number of hours when 50 percent of a large sample of that type of lamp has failed. Color Rendering Index (CRI) The CRI is a measurement of a light source's accuracy in rendering different colors when compared to a reference light source. The highest attainable CRI is 100. Lamps with CRIs above 70 are typically used in office and living environments. Correlated Color Temperature (CCT) The CCT is an indicator of the "warmth" or "coolness" of the color

148

Nature of the effect of the ballast volumes of flash lamps on their emission  

SciTech Connect

The cause of the decrease in laser efficiency during pumping by flash lamps with increased ballast volumes is the unproductive loss of radiation, originating from the ballast volumes, and the associated change in the radiation brightness distribution along the length of the lamp. The increase radiation brightness at the electrodes of the light source is not the result of constriction of the discharge or the luminescence of the electrode plasma erosion, but is due to the slowing down of the plasma flows by the surface of the electrodes and to the slowing down of the ionized gas moving from the ballast volumes when it meets the denser plasma of the discharge zone. The profile of the current lines at the electrodes is established and the frequency of the axial oscillations of the plasma in the lamp is determined.

Basov, Yu.G.; Makarov, V.N.; Narkhova, G.I.

1975-11-01T23:59:59.000Z

149

Energy-Efficient, High-Color-Rendering LED Lamps Using Oxyfluoride and Fluoride Phosphors  

Science Conference Proceedings (OSTI)

LED lamps using phosphor downconversion can be designed to replace incandescent or halogen sources with a 'warm-white' correlated color temperature (CCT) of 2700-3200 K and a color rendering index (CRI) greater than 90. However, these lamps have efficacies of {approx}70% of standard 'cool-white' LED packages (CCT = 4500-6000 K; CRI = 75-80). In this report, we describe structural and luminescence properties of fluoride and oxyfluoride phosphors, specifically a (Sr,Ca){sub 3}(Al,Si)O{sub 4}(F,O):Ce{sup 3+} yellow-green phosphor and a K{sub 2}TiF{sub 6}:Mn{sup 4+} red phosphor, that can reduce this gap and therefore meet the spectral and efficiency requirements for high-efficacy LED lighting. LED lamps with a warm-white color temperature (3088 K), high CRI (90), and an efficacy of {approx}82 lm/W are demonstrated using these phosphors. This efficacy is {approx}85% of comparable cool-white lamps using typical Y{sub 3}Al{sub 5}O{sub 12}:Ce{sup 3+}-based phosphors, significantly reducing the efficacy gap between warm-white and cool-white LED lamps that use phosphor downconversion.

Setlur, A.; Radkov, E; Henderson, C; Her, J; Srivastava, A; Karkada, N; Kishore, M; Kumar, N; Aesram, D; et al.

2010-01-01T23:59:59.000Z

150

History and technical evolution of high frequency fluorescent lighting  

SciTech Connect

This work was performed to accelerate development and commercialization of solid-state, high frequency ballasts for fluorescent lighting systems. The history and development of fluorescent lamps, of ballasts for these fixtures, and of related circuits and equipment are reviewed. The higher lamp efficiency of high-frequency (300 to 3000 Hz) fluorescent lamps as compared with 60 Hz lamps, the development of frequency converter circuits for high-frequency lamps, and uses, electrical characteristics, and economics of these lighting systems are discussed. (LCL)

Campbell, J.H.

1977-12-01T23:59:59.000Z

151

The Effects of Table Lamp Shade Shape and Compact Fluorescent...  

NLE Websites -- All DOE Office Websites (Extended Search)

The Effects of Table Lamp Shade Shape and Compact Fluorescent Lamp Burning Position on Visual Comfort Speaker(s): Zaidi Abdullah Date: March 15, 2001 - 12:00pm Location: Bldg. 90...

152

Sector 7  

NLE Websites -- All DOE Office Websites (Extended Search)

Publications Publications A Reminder for Sector 7 PIs and Users: Please report your new publications to the Sector Manager and the CAT Director. The APS requires PIs to submit new publications to its Publication Database, a link which can be found on the Publication section of the APS web site. Publication information for work done at 7ID Proper acknowledgement sentences to include in papers. Sector 7 Call for APS User Activity Reports. APS User Activity Reports by MHATT-CATers. Recent articles Recent theses Sector 7 Reports Sector 7 Recent research highlights (New) Design documents in ICMS on Sector 7 construction and operation Sector 7 related ICMS documents Library Resources available on the WWW The ANL Library system ANL electronic journal list AIM Find it! Citation Ranking by ISI (see Journal citation report)

153

Experimental and theoretical investigations on the warm-up of a high-pressure mercury discharge lamp  

SciTech Connect

Modern high-pressure discharge lamps are forced to provide instant light and hot relight capabilities - if possible at lower power units. A detailed understanding of the warm-up of high-pressure discharge lamps is therefore required. Complex fluid model codes were developed for the past years including more and more processes like two-dimensional treatment of convection trying to provide a more comprehensive and consistent description of high-pressure discharge lamps. However, there is a lack of experimental data to examine the performance of these models. This work provides a very complete set of geometrical, electrical, spectroscopic, and thermographic data according to the warm-up of a high-pressure mercury discharge lamp that is compared to the results of a state of the art fluid code. Quantitative agreement is achieved for single parameters like wall temperatures. But the paper also reveals the need for further investigations and improvements of the code.

Zalach, J.; Franke, St.; Schoepp, H. [Leibniz Institute for Plasma Science and Technology, Felix-Hausdorff-Str. 2, D-17489 Greifswald (Germany); Araoud, Z.; Charrada, K. [Unite d'Etude des Milieux Ionises et Reactifs, IPEIM, rte de Kairouan, 5019 Monastir (Tunisia); Zissis, G. [Laboratoire Plasma et Conversion d'Energie, 118 rte Narbonne, Bat3R2, 31062 Toulouse (France)

2011-03-15T23:59:59.000Z

154

Efficient Light Sources Today  

E-Print Network (OSTI)

This paper reviews new lamp and lighting technology in terms of application and economic impact. Included are the latest advances in High Intensity Discharge systems, energy saving fluorescent lamps and ballasts, and the new state of the art high performance fluorescent systems. Cost analyses will show that typical owning and operating cost reductions of 15 to 65% can be achieved without sacrificing illumination levels when the right system is chosen and properly applied.

Hart, A. L.

1982-01-01T23:59:59.000Z

155

NOTICE TO APPLICANTS FOR SOLID STATE LIGHTING, IES ...  

Science Conference Proceedings (OSTI)

... _____ 22/P13b* IES LM-66:2000 Single-Ended Compact Fluorescent Lamps - Intensity Measurements ... NVLAP ENERGY EFFICIENT LIGHTING ...

2013-03-28T23:59:59.000Z

156

Chapter 2, Commercial and Industrial Lighting Evaluation Protocol...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

power density (lighting wattsft 2 ), calculated using simple spreadsheets. Other federal, state, and local standards may set additional baseline constraints on lamps,...

157

Solid-State Lighting Issue 28: Selected Business and Technology...  

NLE Websites -- All DOE Office Websites (Extended Search)

be arranged in modules designed to replace cold cathode fluorescent lamps (CCFL), surface light emitting devices such as electro-luminescent panels, and bulbs for car headlights....

158

Neptun Light: Proposed Penalty (2013-CE-3504) | Department of...  

NLE Websites -- All DOE Office Websites (Extended Search)

Civil Penalty that Neptun Light, Inc. failed to certify a variety of medium base compact fluorescent lamps as compliant with the applicable energy conservation standards. DOE...

159

Types of Lighting in Commercial Buildings - Changes  

U.S. Energy Information Administration (EIA) Indexed Site

Changes in Lighting Changes in Lighting The percentage of commercial buildings with lighting was unchanged between 1995 and 2003; however, three lighting types did show change in usage. Compact fluorescent lamps and halogen lamps showed a significant increase between 1995 and 2003 while the use of incandescent lights declined. The lighting questions in the 1995, 1999, and 2003 CBECS questionnaires were virtually identical which facilitates comparison across survey years. The use of compact fluorescent lamps more than doubled, from just under 10 percent of lit buildings to more than 20 percent (Figure 17 and Table 5). The use of halogen lamps nearly doubled, from 7 percent to 13 percent of lit buildings. Use of incandescent lights was the only lighting type to decline; their use dropped from 59 percent to just over one-half of lit buildings.

160

Fluorescent Lighting Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Fluorescent Lighting Basics Fluorescent Lighting Basics Fluorescent Lighting Basics October 17, 2013 - 5:39pm Addthis Light from a fluorescent lamp is first created by an electric current conducted through an inert gas producing ultraviolet light that is invisible to the human eye. The ultraviolet light in turn interacts with special blends of phosphors coating the interior surface of the fluorescent lamp tube that efficiently converts the invisible light into useful white light. Fluorescent lamps require a special power supply called a ballast that is needed to regulate lamp operating current and provide a compatible start-up voltage. Electronic ballasts perform the same function as a magnetic ballast but outperform the outdated magnetic products by operating at a very high frequency that eliminates flicker and noise while

Note: This page contains sample records for the topic "lamp sector lighting" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Neptun Light: Order (2012-SE-3504)  

Energy.gov (U.S. Department of Energy (DOE))

DOE ordered Neptun Light, Inc. to pay a $13,000 civil penalty after finding Neptun Light had failed to certify that certain models of medium base compact fluorescent lamps comply with the applicable energy conservation standards.

162

Lighting Overview Page 6-1 2008 Residential Compliance Manual August 2009  

E-Print Network (OSTI)

intensity discharge lamps (like metal halide lamps) light emitting diode (LED) luminaires (dedicated LED Manual August 2009 §119(m); Table 150(c) LED Certification Requirements. Light emitting diode (LED Lighting Source Systems. For a light emitting diode (LED) lighting source system to qualify as high

163

Lighting  

SciTech Connect

The lighting section of ASHRAE standard 90.1 is discussed. It applies to all new buildings except low-rise residential, while excluding specialty lighting applications such as signage, art exhibits, theatrical productions, medical and dental tasks, and others. In addition, lighting for indoor plant growth is excluded if designed to operate only between 10 p.m. and 6 a.m. Lighting allowances for the interior of a building are determined by the use of the system performance path unless the space functions are not fully known, such as during the initial stages of design or for speculative buildings. In such cases, the prescriptive path is available. Lighting allowances for the exterior of all buildings are determined by a table of unit power allowances. A new addition the exterior lighting procedure is the inclusion of facade lighting. However, it is no longer possible to trade-off power allotted for the exterior with the interior of a building or vice versa. A significant change is the new emphasis on lighting controls.

McKay, H.N. (Hayden McKay Lighting Design, New York, NY (US))

1990-02-01T23:59:59.000Z

164

Advanced Lighting Technologies:Energy Efficiency and Power Quality of Lighting Sources  

Science Conference Proceedings (OSTI)

his EPRI technical update is the third in a series of technical assessments of advanced lighting technologies. A total of seven lighting products were assessed in 2013: low cost screw based light-emitting diode (LED) lamps, retrofit LED ceiling fixtures, suspended LED fixtures, LED-based 2x4 troffers, LED high bay fixtures, innovative LED screw based lamps, and LED hospitality lighting. Prior to beginning an in-depth assessment, the EPRI Lighting Group evaluated each of the tested technologies to ...

2013-12-12T23:59:59.000Z

165

Novel Nanophosphors for High Efficiency Fluorescent Lamps  

SciTech Connect

This is the Final Report of the Novel Nanophosphors for High Efficiency Fluorescent Lamps, Department of Energy (DOE). The overall goal of this three-year program is to develop novel hybrid phosphors by coating commercially available lamp phosphors with highly stable wide band-gap nanocrystalline phosphors (NCP). The prime technical approach is the development of NCP quantum-splitting phosphor (QSP) and ultra-violet (UV) emitting phosphors with quantum efficiencies exceeding that of the conventional phosphors at 185 nm. The novel hybrid phosphors will increase the efficiency of the fluorescent lamps by up to 32%, enabling total energy savings of 0.26 quads, the reduction in the U.S. energy bill by $6.5 billion and the reduction of the annual carbon emission by 4.1 billion kilogram. Our work started by investigating through modeling calculations the requirement for the particle size of the NCP. Our work to develop suitable nanocrystalline phosphors started with the known oxide quantum splitting and UV emitting phosphors. We demonstrated several synthesis techniques for the production of high quality nanocrystalline materials that crystallizes in the desired phase and with the desired particle size. In collaboration with our subcontractor we demonstrated the feasibility for the manufacture of NC phosphors. We also demonstrated novel techniques of coating the NCP on the surface of micron sized phosphors. Our chief achievement pertains to the successful testing of the coated hybrid phosphor systems in linear fluorescent lamps. In linear fluorescent lamp tests, we have demonstrated up to 7% increase in the efficacy of hybrid phosphors over the conventional (uncoated) phosphors. We have also demonstrated the improvement in the lumen maintenance of the coated phosphors. A hybrid phosphor system based on the commercial red emitting phosphor, Y{sub 2}O{sub 3}:Eu{sup 3+} did not show the anticipated improvement in lamp efficacy. We explored the reasons for this observation, which are detailed in this report. Within the program we have carried out fundamental investigations into the physical processes that determine the quantum splitting behavior of the Pr{sup 3+} ion in solids. Specifically, we have investigated the quantum splitting luminescence of this ion in the LaPO{sub 4}, SrAl{sub 12}O{sub 19} and LiLaP{sub 4}O{sub 12} host lattices. In this final report we summarize the technical work completed under the Program, summarize our findings about the performance limits of the various technologies we investigated, and outline promising paths for future work.

Alok Srivatava

2007-03-31T23:59:59.000Z

166

Lighting Research Group: Facilities: Power Analyzer  

NLE Websites -- All DOE Office Websites (Extended Search)

Power Analyzer Power Analyzer Power Analyzer power analyzer Gonio-photometer | Integrating sphere | Power analyzer | Spectro-radiometer A power analyzer is a very necessary tool for lighting research. With the power analyzer we are able to monitor the input voltage to the lamp as well as the input power and current. The amount of power a lamp or a lamp-ballast combination uses is very important when determining its efficiency. It is also important to monitor the input voltage to make sure it doesn't vary. This can affect the light output of a lamp greatly. With the power analyzer we can also measure things like the power factor, harmonic distortion, and current crest factor of some lamps. These measurements tell us how well a lamp is working. For example, a high power

167

Energy Basics: Incandescent Lighting  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

The three most common types of incandescent lamps are: Standard incandescent lamps Energy-Saving Incandescent (or Halogen) Reflector lamps Standard Incandescent Lamps Known as...

168

Stress Testing of the Philips 60W Replacement Lamp L Prize Entry  

SciTech Connect

The Pacific Northwest National Laboratory, operated by Battelle for the U.S. Department of Energy, worked with Intertek to develop a procedure for stress testing medium screw-base light sources. This procedure, composed of alternating stress cycles and performance evaluation, was used to qualitatively compare and contrast the durability and reliability of the Philips 60W replacement lamp L Prize entry with market-proven compact fluorescent lamps (CFLs) with comparable light output and functionality. The stress cycles applied simultaneous combinations of electrical, thermal, vibration, and humidity stresses of increasing magnitude. Performance evaluations measured relative illuminance, x chromaticity and y chromaticity shifts after each stress cycle. The Philips L Prize entry lamps appear to be appreciably more durable than the incumbent energy-efficient technology, as represented by the evaluated CFLs, and with respect to the applied stresses. Through the course of testing, all 15 CFL samples permanently ceased to function as a result of the applied stresses, while only 1 Philips L Prize entry lamp exhibited a failure, the nature of which was minor, non-destructive, and a consequence of a known (and resolved) subcontractor issue. Given that current CFL technology appears to be moderately mature and no Philips L Prize entry failures could be produced within the stress envelope causing 100 percent failure of the benchmark CFLs, it seems that, in this particular implementation, light-emitting diode (LED) technology would be much more durable in the field than current CFL technology. However, the Philips L Prize entry lamps used for testing were carefully designed and built for the competition, while the benchmark CFLs were mass produced for retail sale—a distinction that should be taken into consideration. Further reliability testing on final production samples would be necessary to judge the extent to which the results of this analysis apply to production versions of the Philips L Prize entry.

Poplawski, Michael E.; Ledbetter, Marc R.; Smith, Mark

2012-04-24T23:59:59.000Z

169

Controlling the vapor pressure of a mercury lamp  

DOE Patents (OSTI)

The invention described herein discloses a method and apparatus for controlling the Hg vapor pressure within a lamp. This is done by establishing and controlling two temperature zones within the lamp. One zone is colder than the other zone. The first zone is called the cold spot. By controlling the temperature of the cold spot, the Hg vapor pressure within the lamp is controlled. Likewise, by controlling the Hg vapor pressure of the lamp, the intensity and linewidth of the radiation emitted from the lamp is controlled.

Grossman, Mark W. (Belmont, MA); George, William A. (Rockport, MA)

1988-01-01T23:59:59.000Z

170

Controlling the vapor pressure of a mercury lamp  

DOE Patents (OSTI)

The invention described herein discloses a method and apparatus for controlling the Hg vapor pressure within a lamp. This is done by establishing and controlling two temperature zones within the lamp. One zone is colder than the other zone. The first zone is called the cold spot. By controlling the temperature of the cold spot, the Hg vapor pressure within the lamp is controlled. Likewise, by controlling the Hg vapor pressure of the lamp, the intensity and linewidth of the radiation emitted from the lamp is controlled. 2 figs.

Grossman, M.W.; George, W.A.

1988-05-24T23:59:59.000Z

171

Advanced Lighting Program Development (BG9702800) Final Report  

Science Conference Proceedings (OSTI)

The report presents a long-range plan for a broad-based, coordinated research, development and market transformation program for reducing the lighting energy intensities in commercial and residential buildings in California without compromising lighting quality. An effective program to advance lighting energy efficiency in California must be based on an understanding that lighting is a mature field and the lighting industry has developed many specialized products that meet a wide variety of light needs for different building types. Above all else, the lighting field is diverse and there are applications for a wide range of lighting products, systems, and strategies. Given the range of existing lighting solutions, an effective energy efficient lighting research portfolio must be broad-based and diverse to match the diversity of the lighting market itself. The belief that there is one solution--a magic bullet, such as a better lamp, for example--that will propel lighting efficiency across all uses to new heights is, in the authors' opinion, an illusion. A multi-path program is the only effective means to raising lighting efficiency across all lighting applications in all building types. This report presents a list of 27 lighting technologies and concepts (key activities) that could form the basis of a coordinated research and market transformation plan for significantly reducing lighting energy intensities in California buildings. The total 27 key activities into seven broad classes as follows: Light sources; Ballasts; Luminaires; Lighting Controls; Lighting Systems in Buildings; Human Factors and Education. Each of the above technology classes is discussed in terms of background, key activities, and the energy savings potential for the state. The report concludes that there are many possibilities for targeted research, development, and market transformation activities across all sectors of the building lighting industry. A concerted investment by the state to foster efficiency improvements in lighting systems in commercial and residential buildings would have a major positive impact on energy use and environmental quality in California.

Rubinstein, Francis; Johnson, Steve

1998-02-01T23:59:59.000Z

172

LED lamp color control system and method  

DOE Patents (OSTI)

An LED lamp color control system and method including an LED lamp having an LED controller 58; and a plurality of LED channels 60 operably connected to the LED controller 58, each of the plurality of LED channels 60 having a channel switch 62 in series with at least one shunted LED circuit 83, the shunted LED circuit 83 having a shunt switch 68 in parallel with an LED source 80. The LED controller 58 determines whether the LED source 80 is in a feedback controllable range, stores measured optical flux for the LED source 80 when the LED source 80 is in the feedback controllable range, and bypasses storing the measured optical flux when the LED source 80 is not in the feedback controllable range.

Gaines, James; Clauberg, Bernd; Van Erp, Josephus A.M.

2013-02-05T23:59:59.000Z

173

Experimental methodology for determining the system performance of fluorescent lamp, ballast, fixture combinations operating under realistic application conditions  

SciTech Connect

To meet the need for accurate performance data, an experimental method for determining the performance of lamp, ballast, and luminaire combinations operating under a broad range of realistic conditions was developed. The methodology employs a two-part experimental procedure. The first part uses a temperature-controlled luminous flux integrator to characterize the thermal performance of each lamp/ballast combination. This performance characterization is expressed in terms of light output and efficacy as a function of variations in minimum lamp wall temperature (MLWT) and is generated for the range of temperatures typically encountered in interior lighting applications. The second procedure uses a luminaire/plenum simulator to determine the specific MLWT that exists in a particular luminaire application as a function of luminaire type, mounting configuration, plenum integration, and room air temperature. The MLWTs thus measured may be used in conjunction with the lamp/ballast performance data to determine application-specific values of light output and efficacy for a given lamp/ballast/luminaire system.

Siminovitch, M.J.; Rubinstein, F.M.; Verderber, R.R.

1984-11-01T23:59:59.000Z

174

High output lamp with high brightness  

DOE Patents (OSTI)

An ultra bright, low wattage inductively coupled electrodeless aperture lamp is powered by a solid state RF source in the range of several tens to several hundreds of watts at various frequencies in the range of 400 to 900 MHz. Numerous novel lamp circuits and components are disclosed including a wedding ring shaped coil having one axial and one radial lead, a high accuracy capacitor stack, a high thermal conductivity aperture cup and various other aperture bulb configurations, a coaxial capacitor arrangement, and an integrated coil and capacitor assembly. Numerous novel RF circuits are also disclosed including a high power oscillator circuit with reduced complexity resonant pole configuration, parallel RF power FET transistors with soft gate switching, a continuously variable frequency tuning circuit, a six port directional coupler, an impedance switching RF source, and an RF source with controlled frequency-load characteristics. Numerous novel RF control methods are disclosed including controlled adjustment of the operating frequency to find a resonant frequency and reduce reflected RF power, controlled switching of an impedance switched lamp system, active power control and active gate bias control.

Kirkpatrick, Douglas A. (Great Falls, VA); Bass, Gary K. (Mt. Airy, MD); Copsey, Jesse F. (Germantown, MD); Garber, Jr., William E. (Poolesville, MD); Kwong, Vincent H. (Vancouver, CA); Levin, Izrail (Silver Spring, MD); MacLennan, Donald A. (Gaithersburg, MD); Roy, Robert J. (Frederick, MD); Steiner, Paul E. (Olney, MD); Tsai, Peter (Olney, MD); Turner, Brian P. (Damascus, MD)

2002-01-01T23:59:59.000Z

175

High intensity discharge lamp self-adjusting ballast system sensitive to the radiant energy or heat of the lamp  

SciTech Connect

This patent describes a self-adjusting ballast system for mercury vapor, high intensity discharge lamps having outputs of 100 watts or greater, comprising: a direct current source; a lamp circuit containing a high intensity discharge lamp; sensing means for sensing the radiant energy output of the lamp; a pulse width modulator which, in response to the output of the sensing means, varies the width of the pulses that power the lamp during warm-up of the lamp; a high frequency oscillator; a DC to AC converter that converts current from the direct source to pulses of alternating current for powering the lamp, the converter comprising: at least one switch for gating current to the lamp; a switch control means, responsive to the high frequency oscillator, for controlling the switch and controlling the frequency of the alternating current pulses that power the lamp; current sensing means for sensing the current being supplied to the lamp; and current control means for limiting the current through the lamp to a predetermined safe level when the current sensed by the current sensing means exceeds a reference value.

Kuhnel, D.S.; Ottenstein, S.A.

1987-07-21T23:59:59.000Z

176

Resource-technology combinations for domestic lighting in rural India: A comparative financial evaluation  

Science Conference Proceedings (OSTI)

Financial analysis and evaluation of various resource-technology combinations for rural domestic lighting is undertaken. The options include kerosene lamps, liquefied petroleum gas (LPG) and biogas lamps, solar photovoltaic lighting systems, and electric lamps. The figures of merit considered for financial comparison are the cost per hour of lighting and the cost per unit of useful energy for lighting. Sensitivity of these figures of merit to the uncertainties in the values of some of the input variables has also been studied.

Rubab, S.; Kandpal, T.C. [Indian Inst. of Tech., New Delhi (India). Centre for Energy Studies

1997-10-01T23:59:59.000Z

177

Sector 7  

NLE Websites -- All DOE Office Websites (Extended Search)

Sector 7 : Time Resolved Research Group Sector 7 is operated by the Time Resolved Research Group, which is part of the X-ray Science Division (XSD) of the Advanced Photon Source. Our research focus is the study of Ultrafast fs-laser excitation of matter, using x-ray scattering and spectroscopy techniques. The sector developped two hard x-ray beamlines (7ID and 7BM) focused on time-resolved science. The 7BM beamline has been dedicated for time-resolved radiography of fuel sprays. Sector 7 Links: What's New Beamlines Overview User information: Getting Beamtime Current Research Programs Links to our partners, and collaborators (New) Publications Contact information Operational data (w/ current 7ID schedule) ES&H information (ESAF, EOR, TMS training, User Training)

178

Optimizing U.S. Mitigation Strategies for the Light-Duty Transportation Sector: What We Learn from a Bottom-Up Model  

E-Print Network (OSTI)

2007 with Projections to 2030. Report #DOE/EIA-0383(2007);2006 with Projections to 2030. Report #: DOE/EIA-0383(2006);from petroleum products. By 2030, the transportation sector

Yeh, Sonia; Farrell, Alexander E.; Plevin, Richard J; Sanstad, Alan; Weyant, John

2008-01-01T23:59:59.000Z

179

Advanced lighting guidelines, 1993: Revision 1  

SciTech Connect

The 1993 Advanced Lighting Guidelines document consists of twelve guidelines that provide an overview of specific lighting technologies and design application techniques utilizing energy-efficient lighting practice. Lighting Design Practice assesses energy-efficient lighting strategies, discusses lighting issues, and explains how to obtain quality lighting design and consulting services. Luminaires and Lighting Systems surveys luminaire equipment designed to take advantage of advanced technology lamp products and includes performance tables that allow for accurate estimation of luminaire light output and power input. The additional ten guidelines -- Computer-Aided Lighting Design, Energy-Efficient Fluorescent Ballasts, Full-Size Fluorescent Lamps, Compact Fluorescent Lamps, Tungsten- Halogen Lamps, Metal Halide and HPS Lamps, Daylighting and Lumen Maintenance, Occupant Sensors, Time Scheduling Systems, and Retrofit Control Technologies -- each provide a product technology overview, discuss current products on the lighting equipment market, and provide application techniques. This document is intended for use by electric utility personnel involved in lighting programs, lighting designers, electrical engineers, architects, lighting manufacturers' representatives, and other lighting professionals.

Eley, C.; Tolen, T.M. (Eley Associates, San Francisco, CA (United States)); Benya, J.R. (Luminae Souter Lighting Design, San Francisco, CA (United States)); Rubinstein, F.; Verderber, R. (Lawrence Berkeley Lab., CA (United States))

1993-05-01T23:59:59.000Z

180

Advanced lighting guidelines: 1993. Final report  

Science Conference Proceedings (OSTI)

The 1993 Advanced Lighting Guidelines document consists of twelve guidelines that provide an overview of specific lighting technologies and design application techniques utilizing energy-efficient lighting practice. Lighting Design Practice assesses energy-efficient lighting strategies, discusses lighting issues, and explains how to obtain quality lighting design and consulting services. Luminaires and Lighting Systems surveys luminaire equipment designed to take advantage of advanced technology lamp products and includes performance tables that allow for accurate estimation of luminaire light output and power input. The additional ten guidelines -- Computer-Aided Lighting Design, Energy-Efficient Fluorescent Ballasts, Full-Size Fluorescent Lamps, Compact Fluorescent Lamps, Tungsten-Halogen Lamps, Metal Halide and HPS Lamps, Daylighting and Lumen Maintenance, Occupant Sensors, Time Scheduling Systems, and Retrofit Control Technologies -- each provide a product technology overview, discuss current products on the lighting equipment market, and provide application techniques. This document is intended for use by electric utility personnel involved in lighting programs, lighting designers, electrical engineers, architects, lighting manufacturers` representatives, and other lighting professionals.

Eley, C.; Tolen, T.M. [Eley Associates, San Francisco, CA (United States); Benya, J.R. [Luminae Souter Lighting Design, San Francisco, CA (United States); Rubinstein, F.; Verderber, R. [Lawrence Berkeley Lab., CA (United States)

1993-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "lamp sector lighting" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

L&E: Refrigerated Display Case | The Better Buildings Alliance  

NLE Websites -- All DOE Office Websites (Extended Search)

Lighting & Electrical » Adopt the Lighting & Electrical » Adopt the refrigerated display case lighting performance specification and start saving on your case lighting costs Activities Technology Solutions Teams Lighting & Electrical Space Conditioning Plug & Process Loads Food Service Refrigeration Laboratories Energy Management & Information Systems Public Sector Teams Market Solutions Teams Adopt the refrigerated display case lighting performance specification and start saving on your case lighting costs The LED Refrigerated Display Case Lighting Specification delivers nearly 50% energy savings compared to typical display case lighting. If all retail refrigerated display cases switched today to LED systems, over 2.1 TWh of electricity could be saved annually. LED Refrigerated Display Case Lighting Specification

182

Hybrid electronic ballast operating the HPS lamp at constant power  

SciTech Connect

A hybrid solid-state ballast that operates high-pressure sodium (HPS) lamps at main frequency with constant power through rated life is described. The system utilizes two inductors connected in series and a bidirectional semiconductor switch connected in parallel to one of them. A lamp-starting circuit has also been included in the ballast. The static switch, with phase angle control provided by power feedback, actuates on lamp current compensating variations of the main voltage and increases of lamp arc voltage. The system offers the following: (1) increase of lamp life and system lumen maintenance; (2) power factor and total harmonic distortion of line current comparable to conventional lag ballast; and (3) operating cost savings, both in terms of energy cost and lamp replacement cost.

Kaiser, W. [Univ. de Sao Paulo (Brazil)

1998-03-01T23:59:59.000Z

183

Four firms marketing new lighting products  

SciTech Connect

New lighting products on the market include a screw-in high-pressure sodium (HPS) retrofit from Teron Lighting Corp., a screw-in industrial HPS lamp from Guth Lighting, low-voltage task and display lighting fixtures from Capri Lighting, and a current-reducing device from Remtec. The article describes the energy savings, costs, and specifications of each product. (DCK)

1983-07-04T23:59:59.000Z

184

Compact microwave lamp having a tuning block and a dielectric located in a lamp cavity  

DOE Patents (OSTI)

A microwave lamp having a compact structure utilizing a coupling slot which has a dielectric member extending therethrough and a tuning block adjoining the coupling slot. A non-conventional waveguide is used which has about the width of a WR-284 waveguide and about the length of a WR-340 waveguide.

Simpson, James E. (Gaithersburg, MD)

2000-01-01T23:59:59.000Z

185

Fluorescent lamp unit with magnetic field generating means  

DOE Patents (OSTI)

A fluorescent lamp unit having a magnetic field generating means for improving the performance of the fluorescent lamp is disclosed. In a preferred embodiment the fluorescent lamp comprises four longitudinally extending leg portions disposed in substantially quadrangular columnar array and joined by three generally U-shaped portions disposed in different planes. In another embodiment of the invention the magnetic field generating means comprises a plurality of permanent magnets secured together to form a single columnar structure disposed within a centrally located region defined by the shape of lamp envelope. 4 figs.

Grossman, M.W.; George, W.A.

1989-08-08T23:59:59.000Z

186

Development and characterization of a high CRI LED lamp.  

E-Print Network (OSTI)

??The aim of this thesis is to realize a high CRI LED lamp using the color mixing technique. We start from a high efficiency white… (more)

Meneghesso , Matteo

2012-01-01T23:59:59.000Z

187

Lighting  

DOE Green Energy (OSTI)

For the grand challenge of reducing our energy and carbon footprint, the development of renewable energy and energy efficient technologies offer a potential solution. Energy technologies can reduce our dependence on foreign oil as well as the energy consumed by the petroleum industry, the leading consumer of energy by a U.S. industry sector. Nonetheless, the manufacturing processes utilized to manufacture equipment for alternative energy technologies often involve energy-intensive processes. This undermines some of the advantages to moving to 'green' technologies in the first place. Our answer to the Industrial Technology Program's (ITP) Grand Challenge FOA was to develop a transformational low cost manufacturing process for plastic-based photovoltaics that will lower by over 50% both energy consumption and greenhouse emissions and offer a return-of-investment of over 20%. We demonstrated a Luminescent Solar Concentrator fabricated on a plastic acrylic substrate (i.e. no glass) that increases the power output of the PV cell by 2.2x with a 2% power efficiency as well as an LSC with a 7% power efficiency that increased the power output from the PV cells by 35%. S large area 20-inch x 60-inch building-integrated photovoltaic window was fabricated using contract manufacturing with a 4% power efficiency which improved the power output of the PV cell by over 50%. In addition, accelerated lifetimes of the luminescent material demonstrate lifetimes of 20-years.

Sue A. Carter

2012-09-07T23:59:59.000Z

188

Sector X  

NLE Websites -- All DOE Office Websites (Extended Search)

X X If there is an emergency at ETTP requiring evacuation, Sector X reports to the shelter at: Oak Ridge High School 127 Providence Road Oak Ridge, TN 37830 Take most direct route to northbound Bethel Valley Road toward Oak Ridge. Turn left onto Illinois Avenue (Highway 62). Turn right onto Oak Ridge Turnpike and turn left to Oak Ridge High School. If there is an emergency at ORNL requiring evacuation, Sector X reports to the shelter at: Karns High School 2710 Byington Solway Road Knoxville, TN 37931 Take most direct route to northbound Bethel Valley Road toward Knoxville. Then take a left at Highway 62 (Oak Ridge Highway) eastbound to Knoxville. Take a right onto State Route 131 (Byington Beaver Ridge) to Karns High School. If there is an emergency at Y-12 requiring evacuation, Sector X reports to the shelter at:

189

Sector 7  

NLE Websites -- All DOE Office Websites (Extended Search)

Link to Sector 7 Users and Collaborators Link to Sector 7 Users and Collaborators This is an incomplete list of Partners from Universities and National Labs who use the facilities at Sector 7. If you wish to add a link to your institutional page, do no hesitate to contact Eric Dufresne at the APS. The APS XSD Atomic, Molecular and Optical Physics group Center for Molecular Movies at Copenhagen University Roy Clarke Group at the University of Michigan Rob Crowell Group at BNL Chris Elles's group at Kansas University Argonne's Transportation Technology R&D Center Fuel Injection and Spray Research Group Paul Evans's group web page at the University of Wisconsin Alexei Grigoriev's group at Univ. of Tulsa Eric Landahl's web page at DePaul University The SLAC Pulse Institute Ultrafast Materials Science group (D. Reis and A. Lindenberg)

190

Advanced Lighting Technologies Application Guidelines: 1990  

SciTech Connect

The Advanced Lighting Technologies Application Guidelines document consists of eight guidelines that provide an overview of specific lighting technologies and design application techniques utilizing energy-efficient lighting products. Lighting Design Practice assesses energy-efficient lighting strategies and explains how to obtain quality lighting design and consulting services. Luminaries and Lighting Systems surveys advanced lighting fixture products designed to take advantage of current energy-efficient lamp technologies and includes luminaire tables to allow users to collect photometric performance characteristics for common commercial luminaires. Each of the remaining six guidelines -- Computer-Aided Lighting Design, Energy-efficient and Electronic Ballasts, Full-Size Fluorescent Lamps, Compact Fluorescent Lamps, Conventional Shape Tungsten-Halogen Lamps, and Compact Metal Halide and White High Pressure Sodium Lamps -- includes a technology overview section, a description of current products available on the market, and an applications section. The document is intended for use by electric utility personnel involved in lighting programs, lighting designers, electrical engineers, architects, lighting manufacturers' representatives, and other lighting professionals.

Eley, C. (Eley (Charles) Associates, San Francisco, CA (United States))

1992-09-01T23:59:59.000Z

191

Sector 7  

NLE Websites -- All DOE Office Websites (Extended Search)

: News : News Sector 7 calendar of events. APS News APS Monthly meeting slides What's new at the APS Sector 7? 2013 news 2012 news 2011 news 2010 news 2009 news 2008 news 2007 news 2006 news 2005 news 2004 news 2003 news 2002 news 2001 news 2013 News from APS Sector 7 May 2013: Ruben Reininger et al. recently published an article on the optical design of the SPX Imaging and Microscopy beamline (SPXIM). The details can be found on the RSI web site here. A new web page is now available to guide 7-BM users. See the official 7-BM web page for more details. 2012 News from APS Sector 7 August 2012: Jin Wang gave a talk on August 29, 2012 entitled "The APS 7-BM is Open for Business, Officially!" at the August APS Monthly Operation Meeting. On August 1, Alan Kastengren joined the X-ray Science Division to operate the 7-BM beamline. Alan has been involved in the construction

192

Method and apparatus for mounting a dichroic mirror in a microwave powered lamp assembly using deformable tabs  

DOE Patents (OSTI)

A microwave powered electrodeless lamp includes an improved screen unit having mesh and solid sections with an internal reflector secured at the juncture of the two sections to reflect light into a light-transmitting chamber defined in the lamp microwave cavity by the reflector and the mesh section. A discharge envelope of a bulb is disposed in the light-transmitting chamber. Light emitted from the envelope is prevented by the reflector from entering the cavity portion bounded by the solid section of the screen. The reflector is mounted in the cavity by tabs formed in the screen unit and bendable into the cavity to define support planes abutting respective surfaces of the reflector. The mesh section and tabs are preferably formed by etching a thin metal sheet. 7 figs.

Ury, M.; Sowers, F.; Harper, C.; Love, W.

1998-11-24T23:59:59.000Z

193

Method and apparatus for mounting a dichroic mirror in a microwave powered lamp assembly using deformable tabs  

DOE Patents (OSTI)

A microwave powered electrodeless lamp includes an improved screen unit having mesh and solid sections with an internal reflector secured at the juncture of the two sections to reflect light into a light-transmitting chamber defined in the lamp microwave cavity by the reflector and the mesh section. A discharge envelope of a bulb is disposed in the light-transmitting chamber. Light emitted from the envelope is prevented by the reflector from entering the cavity portion bounded by the solid section of the screen. The reflector is mounted in the cavity by tabs formed in the screen unit and bendable into the cavity to define support planes abutting respective surfaces of the reflector. The mesh section and tabs are preferably formed by etching a thin metal sheet.

Ury, Michael (Bethesda, MD); Sowers, Frank (Frederick, MD); Harper, Curt (Wheaton, MD); Love, Wayne (Olney, MD)

1998-01-01T23:59:59.000Z

194

Fluorescent lamp with static magnetic field generating means  

DOE Patents (OSTI)

A fluorescent lamp wherein magnetic field generating means (e.g., permanent magnets) are utilized to generate a static magnetic field across the respective electrode structures of the lamp such that maximum field strength is located at the electrode's filament. An increase in efficacy during operation has been observed.

Moskowitz, Philip E. (Peabody, MA); Maya, Jakob (Brookline, MA)

1987-01-01T23:59:59.000Z

195

Fluorescent lamp with static magnetic field generating means  

DOE Patents (OSTI)

A fluorescent lamp wherein magnetic field generating means (e.g., permanent magnets) are utilized to generate a static magnetic field across the respective electrode structures of the lamp such that maximum field strength is located at the electrode's filament. An increase in efficacy during operation has been observed. 2 figs.

Moskowitz, P.E.; Maya, J.

1987-09-08T23:59:59.000Z

196

Convection venting lensed reflector-type compact fluorescent lamp system  

DOE Patents (OSTI)

Disclosed herein is a fluorescent lamp housing assembly capable of providing convection cooling to the lamp and the ballast. The lens of the present invention includes two distinct portions, a central portion and an apertured portion. The housing assembly further includes apertures so that air mass is able to freely move up through the assembly and out ventilation apertures. 12 figs.

Pelton, B.A.; Siminovitch, M.

1997-07-29T23:59:59.000Z

197

An Electrical Cathode Model of a High Pressure Sodium Lamp  

Science Conference Proceedings (OSTI)

An electrical cathode model (ECM) of a high pressure sodium lamp (HPS) based on physical laws has been developed. The proposed ECM calculates the instantaneous voltage drop in a cathode sheath and the temperature distribution inside the cathode using ... Keywords: cathode model, HPS lamp ballast designs

Jose Luis Tapia; Joel O. Pacheco Sotelo; Eduardo Diaz Rodriguez; Yulia Nikolaevna Ledeneva; Rene Arnulfo Garcia Hernandez

2010-09-01T23:59:59.000Z

198

Convection venting lensed reflector-type compact fluorescent lamp system  

SciTech Connect

Disclosed herein is a fluorescent lamp housing assembly capable of providing convection cooling to the lamp and the ballast. The lens of the present invention includes two distinct portions, a central portion and an apertured portion. The housing assembly further includes apertures so that air mass is able to freely move up through the assembly and out ventilation apertures.

Pelton, Bruce A. (825 Manor Rd., El Sobrante, CA 94803); Siminovitch, Michael (829 Manor Rd., El Sobrante, CA 94803)

1997-01-01T23:59:59.000Z

199

DEFINING THE EFFECTIVENESS OF UV LAMPS  

Office of Scientific and Technical Information (OSTI)

ARTI-21CR/610-40030-01 ARTI-21CR/610-40030-01 DEFINING THE EFFECTIVENESS OF UV LAMPS INSTALLED IN CIRCULATING AIR DUCTWORK Final Report Date Published - November 2002 Douglas VanOsdell and Karin Foarde RTI P.O. Box 12194 Research Triangle Park, NC 27709-2194 Prepared for the AIR-CONDITIONING AND REFRIGERATION TECHNOLOGY INSTITUTE 4100 N. Fairfax Drive, Suite 200, Arlington, Virginia 22203 Distribution A - Approved for public release; further dissemination unlimited. DISCLAIMER This report was prepared as an account of work sponsored by the Air-Conditioning and Refrigeration Technology Institute (ARTI) under its "HVAC&R Research for the 21 st Century" (21-CR) program. Neither ARTI, the financial supporters of the 21-CR program, or any agency

200

Contrast between the vertical and horizontal mercury discharge lamps  

SciTech Connect

This paper discusses the thermal behavior of a high pressure mercury lamp in a horizontal position, compared with that of a vertical lamp. The model adopted is three-dimensional, steady, and powered DC. After the model validation, we analyzed temperature fields and velocities for the case of the lamp in a horizontal position by comparing it with those of a lamp in vertical position. This setting initially fixed the wall temperature equal to 1000 K. However, the morphology of the temperature profile in the case of the horizontal lamp indicates that the temperature of the wall cannot be uniform. Thus, we have, in a second time, performed an energy balance at the wall to calculate its temperature. This aims to understand the influence of convection on the thermal properties of the source.

Ben Hamida, M. B.; Helali, H.; Araoud, Z.; Charrada, K. [Unite d'Etude des Milieux Ionises et Reactifs, IPEIM, 5019 route de Kairouan Monastir (Tunisia)

2011-06-15T23:59:59.000Z

Note: This page contains sample records for the topic "lamp sector lighting" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Effect of filament power removal on a fluorescent lamp system  

SciTech Connect

Two techniques are used to measure the effects of removing the filament power from a two-lamp, F-40, rapid-start fluorescent lamp system. The changes are measured for a standard CBM core-coil ballast and for a solid-state ballast operating the lamp at high frequency. There is a 4 tp 6% increase in system efficacy when the filament power is removed. Removal of filament power also decreases filament temperature from 1000/sup 0/C to below 700/sup 0/C in lamps operated at 60 Hz, and from above 600/sup 0/C to 300/sup 0/C in lamps operated at high frequency. The study shows that the arc current and anode fall also determine filament temperature.

Verderber, R.R.; Morse, O.; Rubinstein, F.M.

1985-07-01T23:59:59.000Z

202

AlxIn1-xP Amber LEDs for Solid-State Lighting  

Switching to solid-state lamps is forecast to result in a 46% reduction in lighting energy consumption by 2030. •Cumulative energy savings 2010-2030: ...

203

Low-Pressure Sodium Lighting Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Low-Pressure Sodium Lighting Basics Low-Pressure Sodium Lighting Basics Low-Pressure Sodium Lighting Basics August 16, 2013 - 10:17am Addthis Low-pressure sodium lighting provides more energy-efficient outdoor lighting than high-intensity discharge lighting, but it has very poor color rendition. Typical applications include highway and security lighting, where color is not important. Low-pressure sodium lamps work somewhat like fluorescent lamps. Like high-intensity discharge lighting, low-pressure sodium lamps require up to 10 minutes to start and have to cool before they can restart. Therefore, they are most suitable for applications in which they stay on for hours at a time. They are not suitable for use with motion detectors. The chart below compares low-pressure sodium lamps and high-intensity

204

Zinc Oxide and Nitride Nanowire Based Light Emitting Diodes  

E-Print Network (OSTI)

lumens/W, the LED beats the incandescent bulb and is on thefor an LED as opposed to an incandescent light bulb as shownbulb, fluorescent lamp, and blue light emitting diode. (24) (25) 2.2 LED

Lai, Elaine Michelle

2009-01-01T23:59:59.000Z

205

Energy Star Building Upgrade Manual Lighting Chapter 6  

NLE Websites -- All DOE Office Websites (Extended Search)

O&M Manual 34 Dispose of Lamps Properly 35 6.9 Summary 36 Bibliography 36 Glossary G-1 ENERGY STAR Building Manual 2 6. Lighting 6.1 Overview A lighting upgrade is the second...

206

Section 5.4.5 Exterior Lighting: Greening Federal Facilities...  

NLE Websites -- All DOE Office Websites (Extended Search)

that allows plenty of time for both pedestrians and motorists to be seen. LAMP AND BALLAST SELECTION Mercury vapor lights should be avoided. Replace mer- cury vapor lights with...

207

Solid-State Lighting: Market Challenges  

NLE Websites -- All DOE Office Websites (Extended Search)

Market Challenges to someone by Market Challenges to someone by E-mail Share Solid-State Lighting: Market Challenges on Facebook Tweet about Solid-State Lighting: Market Challenges on Twitter Bookmark Solid-State Lighting: Market Challenges on Google Bookmark Solid-State Lighting: Market Challenges on Delicious Rank Solid-State Lighting: Market Challenges on Digg Find More places to share Solid-State Lighting: Market Challenges on AddThis.com... Why SSL LED Basics OLED Basics Using LEDs R&D Challenges Market Challenges Market Challenges Resources Compact Fluorescent Lighting in America PDF Guiding Market Introduction of SSL Products PDF LED Directional Lamps PDF LED MR16 Lamps Recessed LED Downlights PDF General Service LED Lamps PDF What to Ask - A Checklist for Buyers of LED Lighting Products PDF

208

Solid-State Lighting: Using LEDs  

NLE Websites -- All DOE Office Websites (Extended Search)

Using LEDs to someone by E-mail Using LEDs to someone by E-mail Share Solid-State Lighting: Using LEDs on Facebook Tweet about Solid-State Lighting: Using LEDs on Twitter Bookmark Solid-State Lighting: Using LEDs on Google Bookmark Solid-State Lighting: Using LEDs on Delicious Rank Solid-State Lighting: Using LEDs on Digg Find More places to share Solid-State Lighting: Using LEDs on AddThis.com... Why SSL LED Basics OLED Basics Using LEDs R&D Challenges Market Challenges Using LEDs Resources Using LEDs to Their Best Advantage PDF Establishing LED Equivalency PDF LED Directional Lamps LED MR16 Lamps Recessed LED Downlights PDF General Service LED Lamps What to Ask - A Checklist for Buyers of LED Lighting Products More Resources With their unique design and performance characteristics-such as directional light emission, compact profile, superior optical control,

209

The effects of fixture type and HVAC integration on fluorescent lamp/ballast performance  

SciTech Connect

This paper describes the effects of fixture type and lamp compartment air extract characteristics on lamp/ballast performance. A luminaire/plenum/HVAC simulator was used to measure minimum lamp wall temperature inside four fixture types while varying lamp-compartment extract conditions. Experimental data show that the lumen output of the lamp/ballast system varies by 20% and system efficacy by 10%, depending on the type of fixture and lamp-compartment extract technique employed.

Siminovitch, M.J.; Rubinstein, F.M.; Verderber, R.R.; Clark, T.A.

1986-06-01T23:59:59.000Z

210

Energy-efficient lighting system for television  

DOE Patents (OSTI)

A light control system for a television camera which adjusts the power to lamps illuminating the camera viewing area to provide only sufficient artificial illumination necessary to keep the camera iris substantially open is described.

Cawthorne, D.C.

1986-01-29T23:59:59.000Z

211

Application guidance for fluorescent lighting projects  

SciTech Connect

This application guides is intended to help activity personnel retrofit fluorescent lighting. With this guide, an energy manager can determine if replacing T-12 lamp and magnetic ballast fixtures is cost effective.

Rocha, M.

1994-06-01T23:59:59.000Z

212

Incandescent Lighting | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

or pear-shaped A-19 lamps Energy-saving or halogen A-19 lamps Reflector or parabolic reflector (PAR) lamps, sometimes called "flood" or "spot" lamps Standard...

213

Incandescent Lighting | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Incandescent Lighting Incandescent Lighting Incandescent Lighting October 17, 2013 - 6:15pm Addthis Incandescent lighting is the most common, and least energy efficient, type of lighting used in homes. | Photo courtesy of ©iStockphoto/TokenPhoto. Incandescent lighting is the most common, and least energy efficient, type of lighting used in homes. | Photo courtesy of ©iStockphoto/TokenPhoto. Incandescent lamps are often considered the least energy efficient type of electric lighting commonly found in residential buildings. Although inefficient, incandescent lamps possess a number of key advantages--they are inexpensive to buy, turn on instantly, are available in a huge array of sizes and shapes and provide a pleasant, warm light with excellent color rendition. However, because of their relative inefficiency and short life spans, they

214

Incandescent Lighting | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Incandescent Lighting Incandescent Lighting Incandescent Lighting October 17, 2013 - 6:15pm Addthis Incandescent lighting is the most common, and least energy efficient, type of lighting used in homes. | Photo courtesy of ©iStockphoto/TokenPhoto. Incandescent lighting is the most common, and least energy efficient, type of lighting used in homes. | Photo courtesy of ©iStockphoto/TokenPhoto. Incandescent lamps are often considered the least energy efficient type of electric lighting commonly found in residential buildings. Although inefficient, incandescent lamps possess a number of key advantages--they are inexpensive to buy, turn on instantly, are available in a huge array of sizes and shapes and provide a pleasant, warm light with excellent color rendition. However, because of their relative inefficiency and short life spans, they

215

Lighting Research Group: Facilities: Goniometer  

NLE Websites -- All DOE Office Websites (Extended Search)

Goniometer Goniometer gonio-photometer Gonio-Photometer Gonio-photometer | Integrating sphere | Power analyzer | Spectro-radiometer The gonio-photometer (or goniometer for short) is able to measure the illuminance from each portion of a lamp or fixture. There are three main components to the goniometer: (1) the rotating table that the fixture or lamp is placed on, (2) the long arm with a mirror on the end that rotates around the fixture and (3) a light sensor that measures the light reflected by the mirror. The light source (whether it is in a fixture or not) is placed in the middle of the goniometer, sitting on the rotating table. The rotating table can be adjusted up and down to make sure that the light source is in the very center of the goniometer. When the lamp is positioned this way, the

216

Electrodeless lighting RF power source development. Final report  

SciTech Connect

An efficient, solid state RF power source has been developed on this NICE project for exciting low power electrodeless lamp bulbs. This project takes full advantage of concurrent advances in electrodeless lamp technology. Electrodeless lamp lighting systems utilizing the sulfur based bulb type developed by Fusion Lighting, Inc., is an emerging technology which is based on generating light in a confined plasma created and sustained by RF excitation. The bulb for such a lamp is filled with a particular element and inert gas at low pressure when cold. RF power from the RF source creates a plasma within the bulb which reaches temperatures approaching those of high pressure discharge lamp plasmas. At these temperatures the plasma radiates substantial visible light with a spectrum similar to sunlight.

NONE

1996-08-30T23:59:59.000Z

217

Highly Efficient Small Form Factor LED Retrofit Lamp  

SciTech Connect

This report summarizes work to develop a high efficiency LED-based MR16 lamp downlight at OSRAM SYLVANIA under US Department of Energy contract DE-EE0000611. A new multichip LED package, electronic driver, and reflector optic were developed for these lamps. At steady-state, the lamp luminous flux was 409 lumens (lm), luminous efficacy of 87 lumens per watt (LPW), CRI (Ra) of 87, and R9 of 85 at a correlated color temperature (CCT) of 3285K. The LED alone achieved 120 lumens per watt efficacy and 600 lumen flux output at 25 C. The driver had 90% electrical conversion efficiency while maintaining excellent power quality with power factor >0.90 at a power of only 5 watts. Compared to similar existing MR16 lamps using LED sources, these lamps had much higher efficacy and color quality. The objective of this work was to demonstrate a LED-based MR16 retrofit lamp for replacement of 35W halogen MR16 lamps having (1) luminous flux of 500 lumens, (2) luminous efficacy of 100 lumens per watt, (3) beam angle less than 40{sup o} and center beam candlepower of at least 1000 candelas, and (4) excellent color quality.

Steven Allen; Fred Palmer; Ming Li

2011-09-11T23:59:59.000Z

218

Sector 7  

NLE Websites -- All DOE Office Websites (Extended Search)

Research Programs Research Programs Sector 7's research program exploits the brilliance of the APS undulator radiation to perform material research studies with high spatial and temporal resolution. Microbeam studies are made using x-ray beam sizes on the submicron-scale, and time-resolved diffraction measurements are carried out with picosecond resolution. Sector 7's undulator line has experimental enclosures dedicated to both time-resolved and microbeam research. In one of these enclosures (7ID-D), a femtosecond laser facility is set up for ultrafast diffraction and spectroscopy studies in a pump-probe geometry. The 7ID-B hutch is a white beam capable station used for time-resolved phase-contrast imaging and beamline optics development. A third enclosure (7ID-C) is instrumented for high-resolution diffraction studies with a Huber 6-circle diffractometer. The instrument is ideal for thin-film and interface studies, including the recently developed Coherent Bragg Rod Analysis (COBRA) technique. The fs-laser has recently been delivered to 7ID-C so time-resolved laser pump-x-ray probe can be performed in 7ID-C since March 2007. An x-ray streak camera is also being commissioned in 7ID-C. 7ID-C is equipped for microdiffraction studies with a small Huber 4-cicle diffractometer used with zone-plate optics.

219

Ameren Illinois - Lighting Rebates for Businesses (Illinois)...  

Open Energy Info (EERE)

Technologies CustomOthers pending approval, Lighting, Lighting ControlsSensors, LED Exit Signs, LED Lighting Active Incentive Yes Implementing Sector Utility Energy...

220

Lighting in Residential and Commercial Buildings (1993 and 1995 Data)  

U.S. Energy Information Administration (EIA) Indexed Site

Types > 1995 CBECS Lighting Equipment Types > 1995 CBECS Lighting Equipment 1995 CBECS Lighting Equipment Profile Lighting Equipment - Type and Characteristics of Equipment Emits Found In Incandescent Incandescent Light Bulb Produces light by electrically heating a tungsten filament Includes energy-efficient incandescent bulbs, such as Reflector or R-Lamps (accent and task lighting), Parabolic Aluminized Reflector (PAR) lamps (flood and spot lighting), and Ellipsoidal Reflector (ER) lamps (recessed lighting) Highly inefficient because much of the energy is lost as heat 14-18 Lumens Per Watt (LPW) 14% of Lit Commercial Floorspace Standard Fluorescent Lighting with Magnetic Ballast Standard Fluorescent with Magnetic Ballast Produces light by passing electricity through mercury vapor, causing the fluorescent coating to glow or fluoresce

Note: This page contains sample records for the topic "lamp sector lighting" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

New Energy-Saving Fiber Optic Lighting System Lights Up Public Spaces  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Focus to develop a Energy Focus to develop a breakthrough lighting technology that delivers light comparable to conventional lamps while using significantly less energy per lumen, reducing watts per square foot without sacrificing light levels. As a result of DOE SBIR and other government funding, EFO (efficient fiber optics) Lighting Systems can deliver as much as 80% energy savings over halogen or

222

Covered Product Category: Compact Fluorescent Lamps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Covered Product Category: Compact Fluorescent Lamps Covered Product Category: Compact Fluorescent Lamps Covered Product Category: Compact Fluorescent Lamps October 7, 2013 - 10:48am Addthis ENERGY STAR Qualified Products Federal Energy Management Program (FEMP) provides acquisition guidance across a variety of product categories, including compact fluorescent lamps (CFLs), which are an ENERGY STAR-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR.

223

Max Tech and Beyond: High-Intensity Discharge Lamps  

E-Print Network (OSTI)

the reason industry started by developing ceramic MH lampsceramic metal halide lamps, which are the focus of industry’industry had invested in the development of very low wattage ceramic

Scholand, Michael

2012-01-01T23:59:59.000Z

224

COST EFFECTIVENESS OF LONG LIFE INCANDESCENT LAMPS AND ENERGY BUTTONS  

E-Print Network (OSTI)

button, a 100 watt (130 volt) lamp, a 100 watt long lifeFluorescent Watt L I ltage (volts) cu ge ic in s) ative ( 1the diode energy button (83 volts) was obtained by dividing

Verderber, Rudy

2013-01-01T23:59:59.000Z

225

The LAMP QPF Products. Part I: Model Development  

Science Conference Proceedings (OSTI)

The Local AWIPS (Advanced Weather Interactive Processing System) MOS (model output statistics) Program (LAMP) quantitative precipitation forecast (QPF) system produces 1–22-h forecasts of precipitation over the conterminous United States. The ...

Jerome P. Charba

1998-12-01T23:59:59.000Z

226

An ultraviolet barrier-discharge OH molecular lamp  

Science Conference Proceedings (OSTI)

The energy and spectral parameters of a barrier discharge in a mixture of argon with hydroxyl {sup .}OH are studied experimentally. A sealed lamp with the radiation intensity maximum at {lambda} = 309.2 nm, an emitting surface area of {approx}700 cm{sup 2}, and a radiant excitance of 1.5 mW cm{sup -2} has been fabricated. The radiant power of the lamp is 1.1 W. (laser applications and other topics in quantum electronics)

Sosnin, E A; Erofeev, M V; Avdeev, S M; Panchenko, Aleksei N; Panarin, V A; Skakun, V S; Tarasenko, Viktor F; Shitts, D V [Institute of High Current Electronics, Siberian Branch, Russian Academy of Sciences, Tomsk (Russian Federation)

2006-10-31T23:59:59.000Z

227

The effect of lighting system components on lighting quality, energy use, and life-cycle cost  

SciTech Connect

A computational method was developed to examine the effect of lamp, ballast, and fixture selection on the quality and quantity of illumination, energy consumption, and life-cycle cost of lighting systems. Applying this analysis to lighting layouts using different lamp/ballast/fixture combinations suggested that combinations with higher lumen outputs reduced the uniformity of the illuminance distribution at the workplace but did not reduce visibility levels. The use of higher lumen output lamp/ballast/fixture systems and higher efficiency components tended to reduce life-cycle costs as long as the premium cost of the components was not too high.

Rubinstein, F.; Clark, T.; Siminovitch, M.; Verderber, R.

1986-07-01T23:59:59.000Z

228

Heavy Flavor & Dark Sector  

E-Print Network (OSTI)

We consider some contributions to rare processes in $B$ meson decays from a Dark Sector containing 2 light unstable scalars, with large couplings to each other and small mixings with Standard Model Higgs scalars. We show that existing constraints allow for an exotic contribution to high multiplicity final states with a branching fraction as large as $\\mathcal{O}(10^{-4})$, and that exotic particles could appear as narrow resonances or long lived particles which are mainly found in high multiplicity final states from $B$ decays.

Nelson, Ann E

2013-01-01T23:59:59.000Z

229

Studies on Temperature Dependence of Rubidium Lamp for Atomic Frequency Standard  

Science Conference Proceedings (OSTI)

Rb lamp is a very critical component of the Rb atomic clock's Physics Package. The Rb lamp's performance is very sensitive to temperature and its stability. In this paper we discuss the behaviors of Rb Lamp with temperature. The Rb lamp exciter power and temperature of Rb bulb are very important parameters in controlling the performance of the Rb Lamp. It is observed that at temperatures beyond 110 deg. C, the lamp mode changes from the ring to red mode resulting in abnormal broadening of emission lines and self reversal. The results of our studies on spectral analysis of Rb lamp under various operating conditions are reported in the paper.

Ghosal, Bikash; Banik, Alak; Vats, Vaibhav; Pal, Sukamal; Bahl, R. K [Space Applications Centre, ISRO, Ahmedabad-380015 (India)

2011-10-20T23:59:59.000Z

230

Program on Technology Innovation: Advanced Light Source Research  

Science Conference Proceedings (OSTI)

The Advanced Light Source (ALITE) research program is aimed at breakthrough basic research to achieve approximately 150 to 200 lumens per watt for fluorescent light sources, and to increase high intensity discharge light source efficiency by up to 50%. This report describes work on high intensity discharge (HID) lamps. These commercially available lamps currently have efficacies up to 120 lumens per watt (LPW), and radiate approximately 36% of their energy in the visible spectrum and 53% in the infrared ...

2006-03-27T23:59:59.000Z

231

FAQ of Overview of Solid-State Lighting  

NLE Websites -- All DOE Office Websites (Extended Search)

FREQUENTLY ASKED QUESTIONS 3 Leds FREQUENTLY ASKED QUESTIONS 3 Leds 1. What is solid-state lighting? 2. What is a semiconductor? 3. What is a semiconductor LED (light emitting diode)? 4. What is an organic LED (OLED)? 5. Where can I see LED lighting today? 6. How do you produce white light using LEDs? 7. How does solid-state lighting differ from conventional lighting? 8. What is the energy efficiency of solid-state lighting today? How does the energy efficiency compare with incandescent and fluorescent lamps? 9. What is the cost of solid-state lighting today? How does the cost compare with incandescent and fluorescent lamps? 10. What is the quality of the white light using solid-state lighting today? How does it compare with incandescent and fluorescent lamps?

232

Energy-efficient lighting system for television  

DOE Patents (OSTI)

A light control system for a television camera comprises an artificial light control system which is cooperative with an iris control system. This artificial light control system adjusts the power to lamps illuminating the camera viewing area to provide only sufficient artificial illumination necessary to provide a sufficient video signal when the camera iris is substantially open.

Cawthorne, Duane C. (Amarillo, TX)

1987-07-21T23:59:59.000Z

233

Sector 7  

NLE Websites -- All DOE Office Websites (Extended Search)

User Information & Getting Beamtime User Information & Getting Beamtime There are three ways to request beamtime to perform an experiment on APS-7ID. One can request beam time as an APS General User, as an APS Partner User, or one can contact a staff member of Sector 7 to work collaboratively with them using a small amount of staff time to gather preliminary data. 80% of the available beamtime on 7ID is given to General and Partner Users, while 20% is reserved for staff use. Beam time is allocated and announced by email shortly before the start of an experimental run. In October 2002, beamline 7ID welcomed its first APS General Users (GU). To gain access to 7ID, General or Partner Users are required to submit a proposal to the APS GU Website by the specified deadline. Sucessful proposals will be scheduled for the next cycle following the proposal deadline. There are three proposal cycles per year with deadlines about two months before the start of a run. The deadlines and General User forms are available on the web through the APS General User Web site. Specific instructions for new General Users are available on the site. These instructions can be helpful also for new APS Users in general.

234

Sector 7  

NLE Websites -- All DOE Office Websites (Extended Search)

Overview and History Overview and History Sector 7 consists of two APS beamlines: 7-ID: an insertion device beamline based on an APS Type-A Undulator 7-BM: a bend magnet beam line for time-resolved radiography (currently being commissioned) Overview of 7-ID 7-ID comprises four large experimental enclosures designated A, B, C, and D. In 2004, a laser enclosure was also added (7ID-E). Enclosure 7-ID-A is the first optics enclosure and houses a polished Be window, an empty x-ray filter unit, a pair of white beam slits, a water-cooled double crystal diamond monochromator (Kohzu HLD4), and a P4 mode shutter. The beamline vertical offset is 35 mm. Enclosure 7-ID-B is a white-, or monochromatic-beam experimental enclosure. It is equipped with two precision motorized table for alignment and positioning of experimental equipment. This station is used for white-beam imaging or microdiffraction experiments.

235

Cold Light from Hot Atoms and Molecules  

Science Conference Proceedings (OSTI)

The introduction of rare earth atoms and molecules into lighting discharges led to great advances in efficacy of these lamps. Atoms such as Dy, Ho and Ce provide excellent radiation sources for lighting applications, with rich visible spectra, such that a suitable combination of these elements can provide high quality white light. Rare earth molecules have also proved important in enhancing the radiation spectrum from phosphors in fluorescent lamps. This paper reviews some of the current aspects of lighting research, particularly rare earth chemistry and radiation, and the associated fundamental atomic and molecular data.

Lister, Graeme [OSRAM SYLVANIA, CRSL, 71 Cherry Hill Drive, Beverly, MA (United States); Curry, John J. [National Institute of Standards and Technology, Gaithersburg, MD (United States)

2011-05-11T23:59:59.000Z

236

The Jamming point street-lamp in the world of granular media  

E-Print Network (OSTI)

The Jamming of soft spheres at zero temperature, the J-point, has been extensively studied both numerically and theoretically and can now be considered as a safe location in the space of models, where a street lamp has been lit up. However, a recent work by Ikeda et al, 2013 reveals that, in the Temperature/Packing fraction parameter space, experiments on colloids are actually rather far away from the scaling regime illuminated by this lamp. Is it that the J-point has little to say about real system? What about granular media? Such a-thermal, frictional, systems are a-priori even further away from the idealized case of thermal soft spheres. In the past ten years, we have systematically investigated horizontally shaken grains in the vicinity of the Jamming transition. We discuss the above issue in the light of very recent experimental results. First, we demonstrate that the contact network exhibits a remarkable dynamics, with strong heterogeneities, which are maximum at a packing fraction phi star, distinct and smaller than the packing fraction phi dagger, where the average number of contact per particle starts to increase. The two cross-overs converge at point J in the zero mechanical excitation limit. Second, a careful analysis of the dynamics on time scales ranging from a minute fraction of the vibration cycle to several thousands of cycles allows us to map the behaviors of this shaken granular system onto those observed for thermal soft spheres and demonstrate that some light of the J-point street-lamp indeed reaches the granular universe.

Corentin Coulais; Robert P. Behringer; Olivier Dauchot

2013-05-03T23:59:59.000Z

237

Spectrally Enhanced Lighting Program Implementation for Energy Savings: Field Evaluation  

Science Conference Proceedings (OSTI)

This report provides results from an evaluation PNNL conducted of a spectrally enhanced lighting demonstration project. PNNL performed field measurements and occupant surveys at three office buildings in California before and after lighting retrofits were made in August and December 2005. PNNL measured the following Overhead lighting electricity demand and consumption, Light levels in the workspace, Task lighting use, and Occupant ratings of satisfaction with the lighting. Existing lighting, which varied in each building, was replaced with lamps with correlated color temperature (CCT) of 5000 Kelvin, color rendering index (CRI) of 85, of varying wattages, and lower ballast factor electronic ballasts. The demonstrations were designed to decrease lighting power loads in the three buildings by 22-50 percent, depending on the existing installed lamps and ballasts. The project designers hypothesized that this reduction in electrical loads could be achieved by the change to higher CCT lamps without decreasing occupant satisfaction with the lighting.

Gordon, Kelly L.; Sullivan, Gregory P.; Armstrong, Peter R.; Richman, Eric E.; Matzke, Brett D.

2006-08-22T23:59:59.000Z

238

Solid-State Lighting: CALiPER Report 20.1: Subjective Evaluation of Beam  

NLE Websites -- All DOE Office Websites (Extended Search)

Report 20.1: Subjective Report 20.1: Subjective Evaluation of Beam Quality, Shadow Quality, and Color Quality for LED PAR38 Lamps to someone by E-mail Share Solid-State Lighting: CALiPER Report 20.1: Subjective Evaluation of Beam Quality, Shadow Quality, and Color Quality for LED PAR38 Lamps on Facebook Tweet about Solid-State Lighting: CALiPER Report 20.1: Subjective Evaluation of Beam Quality, Shadow Quality, and Color Quality for LED PAR38 Lamps on Twitter Bookmark Solid-State Lighting: CALiPER Report 20.1: Subjective Evaluation of Beam Quality, Shadow Quality, and Color Quality for LED PAR38 Lamps on Google Bookmark Solid-State Lighting: CALiPER Report 20.1: Subjective Evaluation of Beam Quality, Shadow Quality, and Color Quality for LED PAR38 Lamps on Delicious Rank Solid-State Lighting: CALiPER Report 20.1: Subjective

239

Exploration of illumination concepts for underground coal mines. Appendix E. Electronic ballast for the Lucalox high pressure sodium lamp. Final report  

SciTech Connect

The report documents the results of an investigation to develop solid-state ballasts for Lucalox high-pressure sodium lamps. The ballasts were to be used in the modified and new portable and machine-mounted lighting systems designed by the Crouse-Hinds Co., per tasks I through IV of Contract No. H022065.

1976-07-20T23:59:59.000Z

240

Max Tech and Beyond: High-Intensity Discharge Lamps  

E-Print Network (OSTI)

demonstration (like street lights) and commercialization andthe dominant light source for street and roadway lighting,has been a popular light source for street lighting because

Scholand, Michael

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "lamp sector lighting" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

LED Surgical Task Lighting Scoping Study: A Hospital Energy Alliance Project  

SciTech Connect

Tungsten-halogen (halogen) lamps have traditionally been used to light surgical tasks in hospitals, even though they are in many respects ill-suited to the application due to the large percentage of radiant energy outside the visible spectrum and issues with color rendering/quality. Light-emitting diode (LED) technology offers potential for adjustable color and improved color rendition/quality, while simultaneously reducing side-effects from non-visible radiant energy. It also has the potential for significant energy savings, although this is a fairly narrow application in the larger commercial building energy use sector. Based on analysis of available products and Hospital Energy Alliance member interest, it is recommended that a product specification and field measurement procedure be developed for implementation in demonstration projects.

Tuenge, Jason R.

2011-01-17T23:59:59.000Z

242

Types of Lighting in Commercial Buildings - Lighting Types  

U.S. Energy Information Administration (EIA) Indexed Site

Lighting Types Lighting Types The following are the most widely used types of lighting equipment used in commercial buildings. Characteristics such as energy efficiency, light quality, and lifetime vary by lamp type. Standard Fluorescent A fluorescent lamp consists of a sealed gas-filled tube. The gas in the tube consists of a mixture of low pressure mercury vapor and an inert gas such as argon. The inner surface of the tube has a coating of phosphor powder. When an electrical current is applied to electrodes in the tube, the mercury vapor emits ultraviolet radiation which then causes the phosphor coating to emit visible light (the process is termed fluorescence). A ballast is required to regulate and control the current and voltage. Two types of ballasts are used, magnetic and electronic. Electronic ballasts

243

Commercialization of gallium nitride nanorod arrays on silicon for solid-state lighting  

E-Print Network (OSTI)

One important component in energy usage is lighting, which is currently dominated by incandescent and fluorescent lamps. However, due to potentially higher efficiencies and thus higher energy savings, solid-state lighting ...

Wee, Qixun

2008-01-01T23:59:59.000Z

244

Conservation Potential of Compact Fluorescent Lamps in India and Brazil  

E-Print Network (OSTI)

1988. The private sector in Brazil owned (in 1986) 40% ofElectricity Conservation in Brazil: Potential and Pro-electricity consumption in Brazil's residential sector was

Gadgil, A.J.

2008-01-01T23:59:59.000Z

245

Very high efficacy electrodeless high intensity discharge lamps  

DOE Patents (OSTI)

An electrodeless arc lamp comprises an outer jacket hermetically sealing and thermally protecting an arc tube inside which has an upwardly convex bottom center section. The absence of chemically reactive electrode material makes it possible to use metal halides other than iodides. The tube contains chlorides, bromides or a mixture thereof of scandium and sodium in a nearly equimolar relationship in addition to mercury and an inert gas. Good color balance can be obtained at reduced reservoir temperature and with less power loss. Reduction in wall temperature makes it possible to attain longer lamp life.

Johnson, P.D.

1985-10-03T23:59:59.000Z

246

Sector 30 - useful links  

NLE Websites -- All DOE Office Websites (Extended Search)

Useful Links Sector 30 Sector Orientation Form HERIX experiment header for lab book MERIX experiment header for lab book Printing from your laptop at the beamline Other IXS sectors...

247

High-Intensity Discharge Lighting Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

High-Intensity Discharge Lighting Basics High-Intensity Discharge Lighting Basics High-Intensity Discharge Lighting Basics August 15, 2013 - 5:59pm Addthis High-intensity discharge (HID) lighting provides the highest efficacy and longest service life of any lighting type. It can save 75%-90% of lighting energy when it replaces incandescent lighting. Illustration of a high-intensity discharge (HID) lIllustration amp. The lamp is a tall cylindrical shape, and a cutout of the outer tube shows the materials inside. A long, thin cylinder called the arc tube runs through the lamp between two electrodes. The space around the arc tube is labeled as a vacuum. In a high-intensity discharge lamp, electricity arcs between two electrodes, creating an intensely bright light. Mercury, sodium, or metal halide gas

248

What are the lighting requirements for residences? | Building...  

NLE Websites -- All DOE Office Websites (Extended Search)

lamps (2009 IECC, Section 404.1). The 2012 IECC has increased the minimum percentage from 50% to 75%, along with an exception for low-voltage lighting (2012 IECC,...

249

Kansas City Power and Light - Commercial/Industrial Energy Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

fixture Standard T8 LampsBallasts: 2 - 10unit Lighting Power Density: 1watt per square foot High Intensity Fluorescent: 50fixture Pulse Star Metal Halide: 50fixture...

250

Solid-State Lighting: Text-Alternative Version: LED Replacements...  

NLE Websites -- All DOE Office Websites (Extended Search)

Text-Alternative Version: LED Replacements for Linear Fluorescent Lamps to someone by E-mail Share Solid-State Lighting: Text-Alternative Version: LED Replacements for Linear...

251

Solid-State Lighting: Text-Alternative Version: LED Replacement...  

NLE Websites -- All DOE Office Websites (Extended Search)

I'd like to welcome everyone to this webcast on the very timely topic of light emitting diode replacement lamps and the latest on the ENERGY STAR programs efforts in this...

252

Science and Technology Challenges in Solid-State Lighting  

NLE Websites -- All DOE Office Websites (Extended Search)

of 20,000 hours). The operating cost is the cost (per Mlm-hour or Mlmh) to run a light bulb or lamp - basically the ratio between the cost of the fuel and the luminous...

253

White light velocity interferometer  

DOE Patents (OSTI)

The invention is a technique that allows the use of broadband and incoherent illumination. Although denoted white light velocimetry, this principle can be applied to any wave phenomenon. For the first time, powerful, compact or inexpensive sources can be used for remote target velocimetry. These include flash and arc lamps, light from detonations, pulsed lasers, chirped frequency lasers, and lasers operating simultaneously in several wavelengths. The technique is demonstrated with white light from an incandescent source to measure a target moving at 16 m/s. 41 figs.

Erskine, D.J.

1997-06-24T23:59:59.000Z

254

White light velocity interferometer  

DOE Patents (OSTI)

The invention is a technique that allows the use of broadband and incoherent illumination. Although denoted white light velocimetry, this principle can be applied to any wave phenomenon. For the first time, powerful, compact or inexpensive sources can be used for remote target velocimetry. These include flash and arc lamps, light from detonations, pulsed lasers, chirped frequency lasers, and lasers operating simultaneously in several wavelengths. The technique is demonstrated with white light from an incandescent source to measure a target moving at 16 m/s.

Erskine, David J. (Oakland, CA)

1997-01-01T23:59:59.000Z

255

White light velocity interferometer  

DOE Patents (OSTI)

The invention is a technique that allows the use of broadband and incoherent illumination. Although denoted white light velocimetry, this principle can be applied to any wave phenomenon. For the first time, powerful, compact or inexpensive sources can be used for remote target velocimetry. These include flash and arc lamps, light from detonations, pulsed lasers, chirped frequency lasers, and lasers operating simultaneously in several wavelengths. The technique is demonstrated with white light from an incandescent source to measure a target moving at 16 m/s.

Erskine, David J. (Oakland, CA)

1999-01-01T23:59:59.000Z

256

White light velocity interferometer  

DOE Patents (OSTI)

The invention is a technique that allows the use of broadband and incoherent illumination. Although denoted white light velocimetry, this principle can be applied to any wave phenomenon. For the first time, powerful, compact or inexpensive sources can be used for remote target velocimetry. These include flash and arc lamps, light from detonations, pulsed lasers, chirped frequency lasers, and lasers operating simultaneously in several wavelengths. The technique is demonstrated with white light from an incandescent source to measure a target moving at 16 m/s. 41 figs.

Erskine, D.J.

1999-06-08T23:59:59.000Z

257

Electricity Supply Sector  

U.S. Energy Information Administration (EIA)

Electricity Supply Sector Part 1 of 6 Supporting Documents Sector-Specific Issues and Reporting Methodologies Supporting the General Guidelines for the Voluntary

258

System and Battery Charge Control for PV-Powered AC Lighting Systems  

DOE Green Energy (OSTI)

This report reviews a number of issues specific to stand-alone AC lighting systems. A review of AC lighting technology is presented, which discusses the advantages and disadvantages of various lamps. The best lamps for small lighting systems are compact fluorescent. The best lamps for intermediate-size systems are high- or low-pressure sodium. Specifications for battery charging and load control are provided with the goal of achieving lamp lifetimes on the order of 16,000 to 24,000 hours and battery lifetimes of 4 to 5 years. A rough estimate of the potential domestic and global markets for stand-alone AC lighting systems is presented. DC current injection tests were performed on high-pressure sodium lamps and the test results are presented. Finally, a prototype system was designed and a prototype system controller (with battery charger and DC/AC inverter) was developed and built.

Kern, G.

1999-04-01T23:59:59.000Z

259

Evolution in lighting  

SciTech Connect

Lights consume 20-25% of the nation's electricity, establishing strong incentives to develop more efficient lighting strategies. Attention is turning to where, when, and how we light our environment, and the potential savings add up to half the lighting load nationwide. Some types of lamp are more efficient than others, but characteristics other than energy consumption may dictate where they can be used. Current lighting strategies consider task requirements, light quality, and the potential for daylighting. Energy management systems that control the timing and intensity of light and new types of energy-efficient bulbs and fixtures are increasingly attractive to consumers. The effort will require continued research and the awareness of decision makers. 4 references, 8 figures.

Lihach, N.; Pertusiello, S.

1984-06-01T23:59:59.000Z

260

Fewer lights, Brighter Shine in New Hampshire County | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Fewer lights, Brighter Shine in New Hampshire County Fewer lights, Brighter Shine in New Hampshire County Fewer lights, Brighter Shine in New Hampshire County September 20, 2010 - 3:00pm Addthis New sodium lamp lights at Strafford County’s courthouse parking lot are expected to save the county $6,000 on energy bills annually. | Photo courtesy of Strafford County New sodium lamp lights at Strafford County's courthouse parking lot are expected to save the county $6,000 on energy bills annually. | Photo courtesy of Strafford County New sodium lamp lights at Strafford County's courthouse parking lot are expected to save the county $6,000 on energy bills annually. | Photo courtesy of Strafford County | New sodium lamp lights at Strafford County's courthouse parking lot are expected to save the county $6,000 on energy bills annually. | Photo courtesy of Strafford County

Note: This page contains sample records for the topic "lamp sector lighting" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Fewer lights, Brighter Shine in New Hampshire County | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Fewer lights, Brighter Shine in New Hampshire County Fewer lights, Brighter Shine in New Hampshire County Fewer lights, Brighter Shine in New Hampshire County September 20, 2010 - 3:00pm Addthis New sodium lamp lights at Strafford County’s courthouse parking lot are expected to save the county $6,000 on energy bills annually. | Photo courtesy of Strafford County New sodium lamp lights at Strafford County's courthouse parking lot are expected to save the county $6,000 on energy bills annually. | Photo courtesy of Strafford County New sodium lamp lights at Strafford County's courthouse parking lot are expected to save the county $6,000 on energy bills annually. | Photo courtesy of Strafford County | New sodium lamp lights at Strafford County's courthouse parking lot are expected to save the county $6,000 on energy bills annually. | Photo courtesy of Strafford County

262

The Energy Efficiency of the U.S Fluorescent Lamp Ballast Industry  

NLE Websites -- All DOE Office Websites (Extended Search)

The Energy Efficiency of the U.S Fluorescent Lamp Ballast Industry The Energy Efficiency of the U.S Fluorescent Lamp Ballast Industry Speaker(s): Francis Rubinstein Date: February 14, 2008 - 12:00pm Location: 90-3122 Fluorescent lamp ballasts are subject to DOE appliance standards and rulemaking. But currently, only ballasts for older fluorescent lamp types, such as T-12 lamps are subject to minimum efficacy limits. The majority of fluorescent lamps now being shipped (T-8 and T-5 types) type are operated by ballasts that will not be subject to DOE rule until 2011. The metric used by DOE for characterizing the electrical efficiency of the fluorescent lamp-ballast system is called Ballast Efficacy Factor (BEF). Because BEF is not normalized, it is of limited utility for rulemaking and is useless for procurement. But by normalizing BEF to the total lamp power, I have

263

Information on the Fate of Mercury From Fluorescent Lamps Disposed in Landfills  

Science Conference Proceedings (OSTI)

Mercury is contained in energy-efficient fluorescent, mercury-vapor, metal halide, and high-pressure sodium lamps. This report presents information on the potential for air and groundwater contamination when mercury lamps are disposed in municipal landfills.

1995-04-19T23:59:59.000Z

264

Evaluating office-lighting environments: reference lighting power-density data  

SciTech Connect

The document reports on an exercise in archiving in-situ lighting power densities for occupied office lighting environments. Drawing from a previous study where field surveys of existing lighting installations were recorded, the present study extends the data to include referencable lighting power densities for the original conditions. In addition, theoretical alternate ANSI lighting power densities are computed assuming one-for-one replacement with either energy saving or standard lamps and ballasts.

Gillette, G.

1988-01-01T23:59:59.000Z

265

Inrush related problems caused by lamps with electronic drivers and their mitigation  

Science Conference Proceedings (OSTI)

New types of appliances sometimes bring unexpected power quality problems. On several locations it was reported that energy-saving lamps cause random false tripping of circuit breakers. In all of these cases these lamps had electronic drivers. An investigation ... Keywords: energy-saving lamp, false tripping, inrush, mitigation, power quality

Vladimir ?uk; Joseph F. G. Cobben; Wil L. Kling

2011-07-01T23:59:59.000Z

266

Detroit Public Lighting Department - Residential Energy Wise...  

Open Energy Info (EERE)

Multi-Family Residential, Residential Eligible Technologies Ceiling Fan, Lighting, LED Lighting Active Incentive Yes Implementing Sector Utility Energy Category Energy...

267

Assessment of Electrical, Efficiency, and Photometric Performance of Advanced Lighting Technologies: Dimmable Advanced Lighting Tech nologies -- Electronic Fluorescent, High-Intensity Discharge, and Light-Emitting Diode  

Science Conference Proceedings (OSTI)

This EPRI Technical Report is a compilation of four technical updates that address the basic dimming performance of advanced lighting sources: EPRI report 1018476 for linear fluorescent ballasts, 1018477 for hot and cold cathode compact fluorescent lamps, 1018479 for electronic high-intensity discharge (HID) ballasts, and 1018480 for light-emitting diode (LED) lighting. Chapter 1 provides a discussion of basic lighting control, the importance of considering power quality in lighting control, lighting con...

2008-12-22T23:59:59.000Z

268

LED Street and Area Lighting Technologies  

Science Conference Proceedings (OSTI)

Light emitting diodes (LEDs) are being used for applications beyond just indicator lights. One of those applications, street and area lighting, is of considerable interest. This interest is generated by potential reductions that can be achieved in operating costs resulting from lower maintenance costs as well as potentially lower electricity costs that result from the higher efficiency of LED lamps in the systems, the capability to dim and control LED systems, and better light quality. This white paper l...

2008-07-09T23:59:59.000Z

269

Central Electric Cooperative - Non-Residential Lighting Rebate...  

Open Energy Info (EERE)

Government, Tribal Government Eligible Technologies Lighting, Lighting ControlsSensors, LED Lighting Active Incentive Yes Implementing Sector Utility Energy Category Energy...

270

Lighting Market Sourcebook for the U.S.  

E-Print Network (OSTI)

Potentials: Analysis of the Lighting Sector. Doctoral1996b. Residential Lighting: Use and Potential Savings.1993. Research for "The Lighting Pattern Book for Homes",

Vorsatz, D.; Shown, L.; Koomey, J.; Moezzi, M.; Denver, A.; Atkinson, B.

1997-01-01T23:59:59.000Z

271

Lighting a building with a single bulb : toward a system for illumination in the 21st c.; or, A centralized illumination system for the efficient decoupling and recovery of lighting related heat  

E-Print Network (OSTI)

Piping light represents the first tenable method for recovery and reutilization of lighting related heat. It can do this by preserving the energy generated at the lamp as radiative, departing from precedent and avoiding ...

Levens, Kurt Antony, 1961-

1997-01-01T23:59:59.000Z

272

STATEMENT OF CONSIDERATIONS REQUEST BY CREE LIGHTING COMPANY, FOR AN ADVANCE WAIVER OF DOMESTIC AND  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

20 2001 09:52 FR IPL DOE CH 630 252 2779 TO FGCP-HQ P.02/04 20 2001 09:52 FR IPL DOE CH 630 252 2779 TO FGCP-HQ P.02/04 * * STATEMENT OF CONSIDERATIONS REQUEST BY CREE LIGHTING COMPANY, FOR AN ADVANCE WAIVER OF DOMESTIC AND FOREIGN INVENTION RIGHTS UNDER DOE COOPERATIVE AGREEMENT NO. DE-FC26- 00NT40985 W(A)-01-002, CH-1055 The Petitioner, Cree Lighting Company, (Cree), was awarded this cooperative agreement for the performance of work entitled, "Energy Efficient Solid State Lamp". The purpose of the cooperative agreement is to develop high efficiency, high radiance light emitting diode (LED) chip and packaging technology that is expected to lead to novel solid state lamps capable of replacing less energy efficient incandescent and halogen reflector lamps. When compared with current incandescent reflector lamps, this revolutionary new lamp is expected to be three times more

273

Incandescent Lighting Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Incandescent Lighting Basics Incandescent Lighting Basics Incandescent Lighting Basics August 16, 2013 - 10:00am Addthis Incandescent lamps operate simply by heating a metal filament inside a bulb filled with inert gas. Because they operate directly on variety of common power types including common household alternating current or direct current such as batteries or automobiles, they do not require a special power supply or ballast. They turn on up instantly, providing a warm light with excellent color rendition because the light is produced in much the same way as the light from the sun. They can also be easily dimmed using inexpensive controls and are available in a staggering variety of shapes and sizes. However, incandescent lamps have a low efficacy (10-17 lumens per watt) compared with other lighting options and a short average

274

Incandescent Lighting Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Incandescent Lighting Basics Incandescent Lighting Basics Incandescent Lighting Basics August 16, 2013 - 10:00am Addthis Incandescent lamps operate simply by heating a metal filament inside a bulb filled with inert gas. Because they operate directly on variety of common power types including common household alternating current or direct current such as batteries or automobiles, they do not require a special power supply or ballast. They turn on up instantly, providing a warm light with excellent color rendition because the light is produced in much the same way as the light from the sun. They can also be easily dimmed using inexpensive controls and are available in a staggering variety of shapes and sizes. However, incandescent lamps have a low efficacy (10-17 lumens per watt) compared with other lighting options and a short average

275

Quality assurance assessment of new efficient lighting systems for Naval ships. Final report  

SciTech Connect

Ballasts and lamps, which have been selected to replace existing lamp/ballast systems based on improved performance, were tested to determine if they meet standard Naval MIL specifications. Fifty ballasts manufactured by Advance Transformer Corporation and Universal Manufacturing Corp., and 100 lamps manufactured by GTE were tested to determine their quality assurance and durability. These components met all of the MIL specifications that lamp/ballast systems in use must meet. In addition, these new systems have an improved system efficacy, 62 lumens per watt, and lower third harmonics, which will reduce the need for generating capacity for lighting on ships.

Verderber, R.

1984-08-01T23:59:59.000Z

276

ComEd - Business Instant Lighting Discounts Program (Illinois) | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

ComEd - Business Instant Lighting Discounts Program (Illinois) ComEd - Business Instant Lighting Discounts Program (Illinois) ComEd - Business Instant Lighting Discounts Program (Illinois) < Back Eligibility Commercial Industrial Multi-Family Residential Savings Category Appliances & Electronics Commercial Lighting Lighting Program Info Funding Source Illinois Energy Efficiency Portfolio Standard (EEPS) surcharge Start Date 06/01/2012 State Illinois Program Type Utility Rebate Program Rebate Amount Varies by technology ComEd offers the Business Instant Lighting Discounts program to businesses, multi-family properties and private schools. Incentives are available on a variety of reduced wattage lamps which can be installed as a direct replacement for standard lamps without having to rewire the fixture. Eligible lamps include screw-in CFLs, reduced wattage T8 and T5 linear

277

THERMAL ANNEALING OF ZNO FILMS USING HIGH-DENSITY PLASMA ARC LAMPS  

Science Conference Proceedings (OSTI)

Nanostructured materials are rarely synthesized with appropriate phase and/or morphology. In this study, critical additional of as-synthesized nanostructured materials, such as annealing and/or activation of dopants, are addressed using infrared plasma arc lamps (PAL) over areas as large as 1,000 cm2. The broad spectral range of the PAL and the spectral variation of light absorption in nanostructured materials make the selection of processing parameters extremely difficult, posing a major technological barrier. In this study, the measurement of the surface temperature using various techniques for ZnO films on crystalline silicon wafers is discussed. An energy transport model for the simulation of rapid thermal processing using PAL is presented. The experimental and computational results show that the surface temperature cannot be measured directly and that computer simulation results are an effective tool for obtaining accurate data on processing temperatures.

Sabau, Adrian S [ORNL; Dinwiddie, Ralph Barton [ORNL; Xu, Jun [ORNL; Angelini, Joseph Attilio [ORNL; Harper, David C [ORNL

2011-01-01T23:59:59.000Z

278

L Prize Competition Winner 60W Incandesent Replacement Lamp Update  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Technology Deployment Technology Deployment Working Group L Prize ® Competition Winner 60W Incandescent Replacement Lamp Update James E. Rannels, Senior Advisor L Prize Competition D&R International May 23, 2012 Philips Wins First L Prize 2 * August 3, 2011: Philips announced as winner of 60W replacement bulb category * Product distributed thru commercial and retail channels Image courtesy of Philips -...[O]nce an award is made the authorizing Act directs General Services Administration to develop federal purchasing schedules for solid-state lamps that meet or exceed the specifications laid out in the prize category-so long as it is cost effective. I hope the GSA begins this process soon.‖

279

Quality assurance assessment of new efficient lighting systems for naval ships. Final report. Revision  

SciTech Connect

Ballasts and lamps, which have been selected to replace existing lamp/ballast systems based on improved performance, were tested to determine if they meet standard Naval MIL specifications. Fifty ballasts manufactured by Advance Transformer Corporation and Universal Manufacturing Corporation and 100 lamps manufactured by GTE were tested to determine their quality assurance and durability. These components met all of the MIL specifications that lamp/ballast systems in use must meet. These new systems have an improved system efficacy, 62 lumens per watt, and lower third harmonics, which will reduce the need for generating capacity for lighting on ships. An addendum to the original study describes the assessment of the performance of the advanced ballast system with a new F-17 fluorescent lamp. The results indicate the system performs reliably and shows increased efficacy. This new lamp/ballast system reduces the harmonic content to within Navy limits, and improves the power factor, resulting in a 50% reduction in line current.

Verderber, R.R.; Morse, O.; Dumm, C.

1984-12-01T23:59:59.000Z

280

DuraLamp USA: Proposed Penalty (2010-CE-0912) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DuraLamp USA: Proposed Penalty (2010-CE-0912) DuraLamp USA: Proposed Penalty (2010-CE-0912) DuraLamp USA: Proposed Penalty (2010-CE-0912) September 9, 2010 DOE alleged in a Notice of Proposed Civil Penalty that DuraLamp USA, Inc. failed to certify a variety of general service fluorescent lamps as compliant with the applicable energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. DuraLamp USA: Proposed Penalty (2010-CE-0912) More Documents & Publications DuraLamp USA: Order (2010-CE-0912)

Note: This page contains sample records for the topic "lamp sector lighting" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Lighting practices in coal mines of the United States  

SciTech Connect

Existing conditions of underground lighting in coal mines and attitude of coal-mining States toward mine lighting are discussed as expressed in coal-mine regulations. Types of lamps available are listed. Ways of obtaining better illumination with present lighting equipment are suggested.

Hooker, A.B.; Owings, C.W.

1938-01-01T23:59:59.000Z

282

Observed Minimum Illuminance Threshold for Night Market Vendors in Kenya who use LED Lamps  

Science Conference Proceedings (OSTI)

Creation of light for work, socializing, and general illumination is a fundamental application of technology around the world. For those who lack access to electricity, an emerging and diverse range of LED based lighting products hold promise for replacing and/or augmenting their current fuel-based lighting sources that are costly and dirty. Along with analysis of environmental factors, economic models for total cost-ofownership of LED lighting products are an important tool for studying the impacts of these products as they emerge in markets of developing countries. One important metric in those models is the minimum illuminance demanded by end-users for a given task before recharging the lamp or replacing batteries. It impacts the lighting service cost per unit time if charging is done with purchased electricity, batteries, or charging services. The concept is illustrated in figure 1: LED lighting products are generally brightest immediately after the battery is charged or replaced and the illuminance degrades as the battery is discharged. When a minimum threshold level of illuminance is reached, the operational time for the battery charge cycle is over. The cost to recharge depends on the method utilized; these include charging at a shop at a fixed price per charge, charging on personal grid connections, using solar chargers, and purchasing dry cell batteries. This Research Note reports on the observed"charge-triggering" illuminance level threshold for night market vendors who use LED lighting products to provide general and task oriented illumination. All the study participants charged with AC power, either at a fixed-price charge shop or with electricity at their home.

Johnstone, Peter; Jacobson, Arne; Mills, Evan; Radecsky, Kristen

2009-03-21T23:59:59.000Z

283

Lighting fundamentals handbook: Lighting fundamentals and principles for utility personnel  

SciTech Connect

Lighting accounts for approximately 30% of overall electricity use and demand in commercial buildings. This handbook for utility personnel provides a source of basic information on lighting principles, lighting equipment, and other considerations related to lighting design. The handbook is divided into three parts. Part One, Physics of Light, has chapters on light, vision, optics, and photometry. Part Two, Lighting Equipment and Technology, focuses on lamps, luminaires, and lighting controls. Part Three, Lighting Design Decisions, deals with the manner in which lighting design decisions are made and reviews relevant methods and issues. These include the quantity and quality of light needed for visual tasks, calculation methods for verifying that lighting needs are satisfied, lighting economics and methods for evaluating investments in efficient lighting systems, and miscellaneous design issues including energy codes, power quality, photobiology, and disposal of lighting equipment. The handbook contains a discussion of the role of the utility in promoting the use of energy-efficient lighting. The handbook also includes a lighting glossary and a list of references for additional information. This convenient and comprehensive handbook is designed to enable utility lighting personnel to assist their customers in developing high-quality, energy-efficient lighting systems. The handbook is not intended to be an up-to-date reference on lighting products and equipment.

Eley, C.; Tolen, T. (Eley (Charles) Associates, San Francisco, CA (United States)); Benya, J.R. (Luminae Souter Lighting Design, San Francisco, CA (United States))

1992-12-01T23:59:59.000Z

284

Energy conserving automatic light output system  

SciTech Connect

An energy conserving lighting system is provided wherein a plurality of fluorescent lamps are powered by a poorly regulated voltage source power supply which provides a decreasing supply voltage with increasing arc current so as to generally match the volt-ampere characteristics of the lamps. A transistor ballast and control circuit connected in the arc current path controls the arc current, and hence the light output, in accordance with the total ambient light, i.e., the light produced by the lamps together with whatever further light is produced by other sources such as daylight. In another embodiment, a transistor ballast is utilized in combination with an inductive ballast. The transistor ballast provides current control over a wide dynamic range up to a design current maximum at which maximum the transistor is saturated and the inductive ballast takes over the current limiting function. An operational amplifier is preferably connected in the base biassing circuit of the control transistor of the transistor ballast. In an embodiment wherein two sets of lamps with separate inductive ballasts are provided, the arc currents for the two ballasts are scaled or matched to provide the desired light output.

Widmayer, D.F.

1983-07-19T23:59:59.000Z

285

Lighting Principles and Terms | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Principles and Terms Principles and Terms Lighting Principles and Terms July 29, 2012 - 5:20pm Addthis Light quantity, energy consumption, and light quality are the basic principles of lighting. | Photo courtesy of Tadson Bussey. Light quantity, energy consumption, and light quality are the basic principles of lighting. | Photo courtesy of Tadson Bussey. Learn More Find out how to shop for lights by lumens, not watts. To choose the best energy-efficient lighting options for your home, you should understand basic lighting principles and terms. Light Quantity Illumination The distribution of light on a horizontal surface. The purpose of all lighting is to produce illumination. Lumen A measurement of light emitted by a lamp. As reference, a 100-watt

286

New lighting and controls to save 67% at mall  

SciTech Connect

A metal halide lighting system and a Staco control system that dims lighting in response to sunlight should save a Dallas hotel and office mall 67% in electricity costs. The new system replaces quartz lamps in the 160-foot-high atrium. The savings are a combination of state tax credits and lower air conditioning costs, which will pay for the $25,000 project in about 18 months. The metal halide system was chosen over sodium lighting in order to have more attractive color rendition and because it provides about twice as many lumens per watt as the quartz lamps. The Staco system will dim lamps in response to outdoor light and turn lights above a skating rink on and off at prescribed times.

Kennedy, K.

1985-06-17T23:59:59.000Z

287

Lighting the Way with Compact Fluorescent Lighting | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lighting the Way with Compact Fluorescent Lighting Lighting the Way with Compact Fluorescent Lighting Lighting the Way with Compact Fluorescent Lighting April 28, 2009 - 5:00am Addthis John Lippert There is a major push today to get homeowners to adopt compact fluorescent lamp (CFL) light bulbs. They have been on the market for nearly three decades, and many homeowners still do not use them widely. But the tide is definitely turning. Their availability and the percentage of homeowners familiar with the technology and purchasing them for their homes have been steadily rising. The products have improved considerably compared to early products, and their prices have plummeted. The ENERGY STAR® Change a Light, Change the World Campaign has been running now for more than half a dozen years. This campaign is designed to

288

Lighting the Way with Compact Fluorescent Lighting | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lighting the Way with Compact Fluorescent Lighting Lighting the Way with Compact Fluorescent Lighting Lighting the Way with Compact Fluorescent Lighting April 28, 2009 - 5:00am Addthis John Lippert There is a major push today to get homeowners to adopt compact fluorescent lamp (CFL) light bulbs. They have been on the market for nearly three decades, and many homeowners still do not use them widely. But the tide is definitely turning. Their availability and the percentage of homeowners familiar with the technology and purchasing them for their homes have been steadily rising. The products have improved considerably compared to early products, and their prices have plummeted. The ENERGY STAR® Change a Light, Change the World Campaign has been running now for more than half a dozen years. This campaign is designed to

289

Electronic High-Intensity Discharge Lighting  

Science Conference Proceedings (OSTI)

This EPRI Technical Update addresses the most promising controllable energy efficient light source electronic high-intensity discharge (HID) lighting. Business and technical market factors (Chapter 2) explain the upcoming growth of the HID lamp and electronic HID ballast market. Future technical improvements are emphasized along with discussion of the importance of utility involvement in helping their customers make the switch from magnetically-ballasted HID lighting to higher efficiency electronic HID l...

2007-12-21T23:59:59.000Z

290

Synthesis and luminescence properties of rare earth activated phosphors for near UV-emitting LEDs for efficacious generation of white light  

E-Print Network (OSTI)

efficient, high-color-rendering LED lamps using oxyfluoridePhosphor selection for near UV LED solid state lighting,?and application for near UV LED solid state lighting,? ECS.

Han, Jinkyu

2013-01-01T23:59:59.000Z

291

Microwave lamp with multi-purpose rotary motor  

DOE Patents (OSTI)

In a microwave powered electrodeless lamp, a single rotary motor is used to (a) rotate the bulb and (b) provide rotary motion to a blower or pump means for providing cooling fluid to the magnetron and/or to a forced gas cooler for providing cooling gas to the bulb. The blower may consist of only of an impeller without the usual blower housing. The motor, bulb stem and bulb, or motor, bulb stem, bulb and blower may be formed as an integral unit so as to facilitate replacement. 8 figs.

Ury, M.G.; Turner, B.; Wooten, R.D.

1999-02-02T23:59:59.000Z

292

Microwave lamp with multi-purpose rotary motor  

DOE Patents (OSTI)

In a microwave powered electrodeless lamp, a single rotary motor is used to a) rotate the bulb and b) provide rotary motion to a blower or pump means for providing cooling fluid to the magnetron and/or to a forced gas cooling for providing cooler gas to the bulb. The blower may consist of only of an impeller without the usual blower housing. The motor, bulb stem and bulb, or motor, bulb stem, bulb and blower may be formed as an integral unit so as to facilitate replacement.

Ury, Michael G. (Bethesda, MD); Turner, Brian (Myersville, MD); Wooten, Robert D. (Rockville, MD)

1999-01-01T23:59:59.000Z

293

Low pressure arc discharge lamp apparatus with magnetic field generating means  

DOE Patents (OSTI)

A low-pressure arc discharge apparatus having a magnetic field generating means for increasing the output of a discharge lamp is disclosed. The magnetic field generating means, which in one embodiment includes a plurality of permanent magnets, is disposed along the lamp for applying a constant transverse magnetic field over at least a portion of the positive discharge column produced in the arc discharge lamp operating at an ambient temperature greater than about 25 C. 3 figs.

Grossman, M.W.; George, W.A.; Maya, J.

1987-10-06T23:59:59.000Z

294

Sector 1 welcome  

NLE Websites -- All DOE Office Websites (Extended Search)

Welcome to Sector 1 of the Advanced Photon Source (APS) located at Argonne Welcome to Sector 1 of the Advanced Photon Source (APS) located at Argonne National Laboratory (ANL). The Sector 1 beamlines are operated by the Materials Physics & Engineering Group (MPE) of the APS X-ray Science Division (XSD). Sector 1 consists of the 1-ID and 1-BM beamlines, and 80% of the available beamtime is accessible to outside users through the General User program. The main programs pursued at Sector 1 are described below. 1-ID is dedicated to providing and using brilliant, high-energy x-ray beams (50-150 keV) for the following activities: Coupled high-energy small- and wide-angle scattering (HE-SAXS/WAXS) High-energy diffraction microscopy (HEDM) Sector 1 General Layout Stress/strain/texture studies Pair-distribution function (PDF) measurements

295

Fluorescent Lighting  

Energy.gov (U.S. Department of Energy (DOE))

Fluorescent lamps use 25%-35% of the energy used by incandescent lamps to provide the same amount of illumination (efficacy of 30-110 lumens per watt). They also last about 10 times longer (7,000-24,000 hours).

296

Tailoring optical properties of light-emitting diodes by nanostructuring with nanospheres.  

E-Print Network (OSTI)

???III-V nitride based light-emitting diodes (LEDs) have experienced rapid developments during past decade, proving their potential to substitute conventional incandescent bulbs and fluorescent lamps to… (more)

??

2012-01-01T23:59:59.000Z

297

Energy Engineering Analysis Program (EEAP), Fort Bliss headquarters building, lighting retrofit, Fort Bliss, El Paso, Texas  

SciTech Connect

The purpose of this study is to analyze the use of high efficiency fluorescent lighting with energy efficient lamps and electronic ballast for the Headquarters Building (Bldg. number 2) at Fort Bliss.

1993-02-01T23:59:59.000Z

298

Observed Minimum Illuminance Threshold for Night Market Vendors in Kenya who use LED Lamps  

E-Print Network (OSTI)

for Small Businesses in Kenya." Lumina Project Technicalfor Night Market Vendors in Kenya who use LED Lamps Petermany people and businesses in Kenya who participated in this

Johnstone, Peter

2009-01-01T23:59:59.000Z

299

Guidance Concerning Enforcement of EISA 2007 Standards Candelabra Base and Intermediate Base Lamps  

Energy.gov (U.S. Department of Energy (DOE))

The Energy Independence and Security Act of 2007 (EISA 2007) imposed energy conservation standards for candelabra and intermediate base lamps, and those provisions became effective with the statute.

300

EA-1911: Energy Conservation Standards for Certain Reflector, Elliptical Reflector, and Bulged Reflector Incandescent Lamps  

Energy.gov (U.S. Department of Energy (DOE))

This EA will evaluate the environmental impacts of a proposal to amend energy conservation standards for Certain Reflector, Elliptical Reflector, and Bulged Reflector Incandescent Lamps.

Note: This page contains sample records for the topic "lamp sector lighting" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Dimming of Compact Fluorescent Lamps Caused By Cold-Air Drafts  

Science Conference Proceedings (OSTI)

This Case Study documents the investigation performed by the New York Port Authority (PA) of the dimming of compact fluorescent lamps (CFLs) in the World Trade Center.

2003-12-31T23:59:59.000Z

302

Propane Demand by Sector  

U.S. Energy Information Administration (EIA)

We will be watching the agricultural sector, since the Agriculture Economic Research Service has predicted a record corn crop this year. ...

303

DOE Science Showcase - Light-emitting Diode (LED) Lighting Research | OSTI,  

Office of Scientific and Technical Information (OSTI)

Science Showcase - Light-emitting Diode (LED) Lighting Research Science Showcase - Light-emitting Diode (LED) Lighting Research Light-emitting diode (LED) lighting is a type of solid-state lighting that uses a semiconductor to convert electricity to light. LED lighting products are beginning to appear in a wide variety of home, business, and industrial products such as holiday lighting, replacement bulbs for incandescent lamps, street lighting, outdoor area lighting and indoor ambient lighting. Over the past decade, LED technology research and development supported by the U.S. Department of Energy (DOE) has yielded impressive improvements in the cost, color performance, light output, efficacy, reliability, lifetime, and manufacturability of LED products and this upward trend is expected to continue. Read about the latest DOE research, the technology behind LEDs,

304

Energy 101: Lighting Choices | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

101: Lighting Choices 101: Lighting Choices Energy 101: Lighting Choices August 13, 2013 - 2:38pm Addthis Learn about energy-efficient light bulbs that can light your home for less money. For many years, researchers have been working on new lighting options that produce the same light with less energy. Many of those designs are now on the market. This edition of Energy 101 features newer energy-saving light bulbs that provide the choices in colors and light levels you've come to expect, but with higher efficiencies-so they save you money. Upgrading 15 of the inefficient incandescent light bulbs in your home to energy-saving incandescent, compact fluorescent lamp (CFL), or light emitting diode (LED) bulbs could save you about $50 per year. For more information on lighting choices from the Office of Energy

305

Energy 101: Lighting Choices | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy 101: Lighting Choices Energy 101: Lighting Choices Energy 101: Lighting Choices August 13, 2013 - 2:38pm Addthis Learn about energy-efficient light bulbs that can light your home for less money. For many years, researchers have been working on new lighting options that produce the same light with less energy. Many of those designs are now on the market. This edition of Energy 101 features newer energy-saving light bulbs that provide the choices in colors and light levels you've come to expect, but with higher efficiencies-so they save you money. Upgrading 15 of the inefficient incandescent light bulbs in your home to energy-saving incandescent, compact fluorescent lamp (CFL), or light emitting diode (LED) bulbs could save you about $50 per year. For more information on lighting choices from the Office of Energy

306

Analysis of Energy Use in Building Services of the Industrial Sector in California: A Literature Review and a Preliminary Characterization  

E-Print Network (OSTI)

in that sector went for space conditioning and lighting. Ourmay dramatically affect space conditioning requirements. BAHpurchased energy use for space conditioning and lighting in

Akbari, H.

2008-01-01T23:59:59.000Z

307

Performance of the Services Sector in Korea: An Empirical Investigation  

E-Print Network (OSTI)

There is a widespread perception that Korea’s services sector lags behind its dynamic world-class manufacturing sector. We empirically analyze the past performance of Korea’s services sector in order to assess its prospects as an engine of growth. Our analysis resoundingly confirms the conventional wisdom of an underperforming service sector. In light of Korea’s high income and development level, the poor performance of modern services is of particular concern. We identify a number of factors underlying the poor performance, and set forth policy recommendations for addressing them. Overall, Korea faces a challenging but navigable road ahead in developing a high value-added services sector.

Donghyun Park; Kwanho Shin

2012-01-01T23:59:59.000Z

308

Perception Thresholds of Flicker in Modern Lighting  

Science Conference Proceedings (OSTI)

This power quality (PQ) case study reports the results of tests performed at the University of New Brunswick Department of Psychology to determine whether perception thresholds of humans to flicker in modern magnetic, electronic, and halogen lighting is significantly different from their reaction to flicker in a standard 60-watt incandescent lamp.

2003-12-31T23:59:59.000Z

309

Cornell University Electric Lighting Report  

NLE Websites -- All DOE Office Websites (Extended Search)

Electric Lighting Quality Electric Lighting Quality The CUSD lighting design team utilized energy efficient products that meshed well with our daylighting scheme. We chose to use fluorescent tubes or compact fluorescent bulbs with an energy consumption of between 15 and 30 Watts throughout the house. The ballasts for all lamps dim to a 1% light output, so the interior and exterior lights can be adjusted as the level of available daylight fluctuates. Light sensors have been placed in front of our two largest apertures, allowing us to control how much artificial light is supplied to each space. The control of our ballasts is intricate, but refined and tested to avoid dysfunctional dimming or switching. While automatic controls are included, manual user overrides are provided in case the occupant prefers

310

Yukawa sector in SO(10) (Abstract)  

Science Conference Proceedings (OSTI)

Grand Unified Theories based on the group SO(10) generically provide interesting and testable relations between the charged fermions and neutrino sector masses and mixings. In the light of the recent neutrino data, we reexamine these relations both in supersymmetric and non-supersymmetric models, and give a brief review of their present status.

Melfo, A. [CFF, Universidad de Los Andes, Merida (Venezuela)

2007-10-03T23:59:59.000Z

311

Energy 101: Lighting Choices | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lighting Choices Lighting Choices Energy 101: Lighting Choices Addthis Below is the text version for the Energy 101: Lighting Choices video: The video opens with "Energy 101: Lighting Choices." This is followed by shots of a variety of lamps being turned on. We're all used to lighting up dark spaces with the flip of a switch. In fact, people have been doing so since Thomas Edison invented the incandescent light bulb about 130 years ago...and we've used that same old bulb ever since. The video shows a store aisle with a diverse light bulb selection, then moves to close-ups of the packaging labels on various bulbs. Today you'll see more light bulb options in stores. These bulbs will give you the light you want while saving you energy...and money. A hand screws in a light bulb and flips the switch. The bulb is shown in

312

Max Tech and Beyond: High-Intensity Discharge Lamps  

E-Print Network (OSTI)

presents the national energy consumption profile for HIDVolume I: National Lighting Inventory and Energy Consumption

Scholand, Michael

2012-01-01T23:59:59.000Z

313

Demonstration of LED Retrofit Lamps at an Exhibit of 19th Century Photography at the Getty Museum  

SciTech Connect

This document is a report of observations and results obtained from a lighting demonstration project conducted under the U.S. Department of Energy (DOE) GATEWAY Demonstration Program. The program supports demonstrations of high-performance solid-state lighting (SSL) products in order to develop empirical data and experience with in-the-field applications of this advanced lighting technology. The DOE GATEWAY Demonstration Program focuses on providing a source of independent, third-party data for use in decision-making by lighting users and professionals; this data should be considered in combination with other information relevant to the particular site and application under examination. Each GATEWAY Demonstration compares SSL products against the incumbent technologies used in that location. Depending on available information and circumstances, the SSL product may also be compared to alternate lighting technologies. Though products demonstrated in the GATEWAY program may have been prescreened for performance, DOE does not endorse any commercial product or in any way guarantee that users will achieve the same results through use of these products. This report reviews the installation and use of LED PAR38 lamps to light a collection of toned albument photographic prints at the J. Paul Getty Museum in Malibu, California. Research results provided by the Getty Conservation Institute are incorporated and discussed.

Miller, Naomi J.; Druzik, Jim

2012-03-02T23:59:59.000Z

314

Spectral irradiance model for tungsten halogen lamps in 340-850 nm wavelength range  

Science Conference Proceedings (OSTI)

We have developed a physical model for the spectral irradiance of 1 kW tungsten halogen incandescent lamps for the wavelength range 340-850 nm. The model consists of the Planck's radiation law, published values for the emissivity of tungsten, and a residual spectral correction function taking into account unknown factors of the lamp. The correction function was determined by measuring the spectra of a 1000 W, quartz-halogen, tungsten coiled filament (FEL) lamp at different temperatures. The new model was tested with lamps of types FEL and 1000 W, 120 V quartz halogen (DXW). Comparisons with measurements of two national standards laboratories indicate that the model can account for the spectral irradiance values of lamps with an agreement better than 1% throughout the spectral region studied. We further demonstrate that the spectral irradiance of a lamp can be predicted with an expanded uncertainty of 2.6% if the color temperature and illuminance values for the lamp are known with expanded uncertainties of 20 K and 2%, respectively. In addition, it is suggested that the spectral irradiance may be derived from resistance measurements of the filament with lamp on and off.

Ojanen, Maija; Kaerhae, Petri; Ikonen, Erkki

2010-02-10T23:59:59.000Z

315

Compact light source performance in recessed type luminaires  

SciTech Connect

Photometric comparisons were made with an indoor, recessed, type luminaire using incandescent, high intensity discharge and compact fluorescent lamps. The test results show substantial performance advantages, as expected, for the discharge light sources where the efficacy gains can be in the order for 400% even when including the ballast losses associated with the discharge lamps. The candlepower distribution patterns emerging from these luminaries are also different from those associated with the baseline incandescent lamps, and which are in some ways, even more desirable from a uniformity of illuminance perspective. A section on fluorescent lamp starting is also included which describes a system having excellent starting characteristics in terms of electrode starting temperature (RH/RC technique), proper operating frequency to minimize unwanted IR interactions, and satisfactory current crest factor values to help insure life performance.

Hammer, E.E.

1998-11-01T23:59:59.000Z

316

Over the past decade, lighting became more efficient across ...  

U.S. Energy Information Administration (EIA)

The Department of Energy (DOE) recently released a study of the 2010 lighting market, finding that lighting across all sectors became more energy ...

317

Public Sector Energy Efficiency  

NLE Websites -- All DOE Office Websites (Extended Search)

Capitol dome Capitol dome Public Sector Energy Efficiency Research on sustainable federal operations supports the implementation of sustainable policies and practices in the public sector. This work serves as a bridge between the technology development of Department of Energy's National Laboratories and the operational needs of public sector. Research activities involve many aspects of integrating sustainability into buildings and government practices, including technical assistance for sustainable building design, operations, and maintenance; project financing for sustainable facilities; institutional change in support of sustainability policy goals; and procurement of sustainable products. All of those activities are supported by our work on program and project evaluation, which analyzes overall program effectiveness while ensuring

318

Sustainable LED Fluorescent Light Replacement Technology  

SciTech Connect

Ilumisys and the National Center for Manufacturing Sciences (NCMS) partnered on a three-year project awarded by the United States (U.S.) Department of Energy (DOE), to quantify the impacts of LED lamps, incandescent lamps and fluorescent benchmark lamps over a product lifecycle – i.e. to develop a sustainable design and manufacturing strategy that addresses product manufacturing, use, recycling and disposal scenarios for LED-based lighting. Based on the knowledge gained from extensive product tear-down studies of fluorescent and screw-in lighting products, lifecycle assessment tools, and accelerated lifecycle testing protocols, an interactive Sustainable LED Design Guide has been developed to aid architectural and lighting designers and engineers in making design decisions that consider three important environmental impacts (greenhouse gas emissions, energy use and mercury emission) across all phases of the life of an LED lighting product. Critical information developed for the lifecycle analysis and product feature comparisons is the useful life of the lighting product as well as its performance. The Design Guide is available at www.ncms.org, and was developed based on operational and durability testing of a variety of lighting products including power consumption, light output, and useful life of a lamp in order to allow a more realistic comparison of lamp designs. This report describes the main project tasks, results and innovative features of the lifecycle assessment (LCA)-based design tools, and the key considerations driving the sustainable design of LED lighting systems. The Design Guide incorporates the following three novel features for efficiently evaluating LED lighting features in value-chains: • Bill-of-Materials (BOM) Builder – Designers may import process data for each component and supply functional data for the product, including power, consumption, lumen output and expected useful life. • Environmental Impact Review – Designs are comparable across lifecycle phases, subsystems, and environmental impact category, and can be normalized to a userdefined functional unit. • Drill-down Review – These provide an indepth look at individual lamp designs with the ability to review across subsystem or lifecycle phase.

None

2011-06-30T23:59:59.000Z

319

Westinghouse Lighting: Noncompliance Determination (2010-CE-09/1001) |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Westinghouse Lighting: Noncompliance Determination Westinghouse Lighting: Noncompliance Determination (2010-CE-09/1001) Westinghouse Lighting: Noncompliance Determination (2010-CE-09/1001) June 14, 2010 DOE issued a Notice of Noncompliance Determination to Westinghouse Lighting Corporation finding that various models of incandescent reflector lamps do not comport with the energy conservation standards. DOE determined the products were noncompliant based on the company's own testing. Westinghouse Lighting must immediately notify each person (or company) to whom Westinghouse Lighting distributed the noncompliant products that the products do not meet Federal standards. In addition, Westinghouse Lighting must provide to DOE documents and records showing the number of units Westinghouse Lighting distributed and to whom. The manufacturer

320

West Oahu Solar Powered LED Lighting System  

Science Conference Proceedings (OSTI)

This report describes the design and construction of a solar powered lighting system on the island of Oahu that uses a new Light Emitting Diode (LED) lamp technology. With oil in limited supply and ever increasing energy costs, the construction of photovoltaic (PV) systems has the potential to reduce Hawaiis dependence on imported fossil fuels and help Hawaiian Electric Company (HECO) to meet Hawaiis Renewable Portfolio Standards (RPS).

2006-03-21T23:59:59.000Z

Note: This page contains sample records for the topic "lamp sector lighting" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Sector 6 Research Highlights  

NLE Websites -- All DOE Office Websites (Extended Search)

MM-Group Home MM-Group Home MMG Advisory Committees Beamlines 4-ID-C Soft Spectroscopy 4-ID-D Hard Spectroscopy 6-ID-B,C Mag. Scattering 6-ID-D HighE Scattering 29-ID IEX - ARPES,RSXS Getting Beamtime Sector Orientation Sector 4 Orientation Sector 6 Orientation Publications (4-ID) Publications (6-ID) Contact Us APS Ring Status Current APS Schedule Highlights of research on Sector 6 Teasing Out the Nature of Structural Instabilities in Ceramic Compounds Teasing Out the Nature of Structural Instabilities in Ceramic Compounds March 12, 2013 Researchers have used beamlines 6-ID-B at the APS and XmAS at the ESRF to probe the structure of the rare-earth magnetic material europium titanate. In a magnetic field, the optical properties of this system change quite dramatically, presenting hope of a strong magneto-electric material for potential use in new memory, processing, and sensor devices.

322

sector | OpenEI  

Open Energy Info (EERE)

sector sector Dataset Summary Description This dataset comes from the Energy Information Administration (EIA), and is part of the 2011 Annual Energy Outlook Report (AEO2011). This dataset is table 5, and contains only the reference case. The dataset uses quadrillion btu. The data is broken down into residential, commercial, industrial, transportation, electric power and total energy consumption. Source EIA Date Released April 26th, 2011 (3 years ago) Date Updated Unknown Keywords 2011 AEO EIA Energy Consumption sector South Atlantic Data application/vnd.ms-excel icon AEO2011: Energy Consumption by Sector and Source - South Atlantic- Reference Case (xls, 297.6 KiB) Quality Metrics Level of Review Peer Reviewed Comment Temporal and Spatial Coverage Frequency Annually

323

Buildings Sector Analysis  

DOE Green Energy (OSTI)

A joint NREL, ORNL, and PNNL team conducted market analysis to help inform DOE/EERE's Weatherization and Intergovernmental Program planning and management decisions. This chapter presents the results of the market analysis for the Buildings sector.

Hostick, Donna J.; Nicholls, Andrew K.; McDonald, Sean C.; Hollomon, Jonathan B.

2005-08-01T23:59:59.000Z

324

Buildings Sector Analysis  

SciTech Connect

A joint NREL, ORNL, and PNNL team conducted market analysis to help inform DOE/EERE's Weatherization and Intergovernmental Program planning and management decisions. This chapter presents the results of the market analysis for the Buildings sector.

Hostick, Donna J.; Nicholls, Andrew K.; McDonald, Sean C.; Hollomon, Jonathan B.

2005-08-01T23:59:59.000Z

325

Residential Sector Demand Module  

Reports and Publications (EIA)

Model Documentation - Documents the objectives, analytical approach, and development of the National Energy Modeling System (NEMS) Residential Sector Demand Module. The report catalogues and describes the model assumptions, computational methodology, parameter estimation techniques, and FORTRAN source code.

Owen Comstock

2012-12-19T23:59:59.000Z

326

Residential Sector Demand Module  

Reports and Publications (EIA)

Model Documentation - Documents the objectives, analytical approach, and development of the National Energy Modeling System (NEMS) Residential Sector Demand Module. The report catalogues and describes the model assumptions, computational methodology, parameter estimation techniques, and FORTRAN source code.

Owen Comstock

2013-11-05T23:59:59.000Z

327

EXC-12-0005 - In the Matter of Halco Lighting Technologies | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

5 - In the Matter of Halco Lighting Technologies 5 - In the Matter of Halco Lighting Technologies EXC-12-0005 - In the Matter of Halco Lighting Technologies On July 10, 2012, OHA issued a decision granting an Application for Exception filed by Halco Lighting Technologies (Halco) for relief from the provisions of 10 C.F.R. Part 430, Energy Conservation Program: Energy Conservation Standards and Test Procedures for General Service Fluorescent Lamps and Incandescent Reflector Lamps (Lighting Efficiency Standards). In its exception request, Halco asserted that it will suffer a serious hardship, gross inequity and an unfair distribution of burdens if required to adhere to the new Lighting Efficiency Standards, effective July 14, 2012 (2009 Final Rule), with respect to its 700 series T8 General Service Fluorescent Lamps (GSFL). Specifically, Halco cited previous requests for

328

EXC-12-0014 - In the Matter of Topaz Lighting Corporation | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4 - In the Matter of Topaz Lighting Corporation 4 - In the Matter of Topaz Lighting Corporation EXC-12-0014 - In the Matter of Topaz Lighting Corporation On November 16, 2012, OHA issued a decision granting an Application for Exception filed by Topaz Lighting Corporation (Topaz) for relief from the provisions of 10 C.F.R. Part 430, Energy Conservation Program: Energy Conservation Standards and Test Procedures for General Service Fluorescent Lamps and Incandescent Reflector Lamps (Lighting Efficiency Standards). In its exception request, Topaz asserted that it will suffer a serious hardship, gross inequity and an unfair distribution of burdens if required to adhere to the new Lighting Efficiency Standards, effective July 14, 2012 (2009 Final Rule), with respect to its 700 series T8 General Service Fluorescent Lamps (GSFL). Specifically, Topaz cited a previous OHA

329

EXC-12-0011 - In the Matter of Westinghouse Lighting Corporation |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1 - In the Matter of Westinghouse Lighting Corporation 1 - In the Matter of Westinghouse Lighting Corporation EXC-12-0011 - In the Matter of Westinghouse Lighting Corporation On September 17, 2012, OHA issued a decision granting an Application for Exception filed by Westinghouse Lighting Corporation (Westinghouse) for relief from the provisions of 10 C.F.R. Part 430, Energy Conservation Program: Energy Conservation Standards and Test Procedures for General Service Fluorescent Lamps and Incandescent Reflector Lamps (Lighting Efficiency Standards). In its exception request, Westinghouse asserted that it will suffer a serious hardship, gross inequity and an unfair distribution of burdens if required to adhere to the Lighting Efficiency Standards, which became effective July 14, 2012 (2009 Final Rule), with respect to its 700 series T8 General Service Fluorescent Lamps (GSFL).

330

Solid-State Lighting: Text-Alternative Version: LED Site Lighting in the  

NLE Websites -- All DOE Office Websites (Extended Search)

Site Lighting in the Commercial Building Sector: Opportunities, Challenges, Site Lighting in the Commercial Building Sector: Opportunities, Challenges, and the CBEA Performance Specification to someone by E-mail Share Solid-State Lighting: Text-Alternative Version: LED Site Lighting in the Commercial Building Sector: Opportunities, Challenges, and the CBEA Performance Specification on Facebook Tweet about Solid-State Lighting: Text-Alternative Version: LED Site Lighting in the Commercial Building Sector: Opportunities, Challenges, and the CBEA Performance Specification on Twitter Bookmark Solid-State Lighting: Text-Alternative Version: LED Site Lighting in the Commercial Building Sector: Opportunities, Challenges, and the CBEA Performance Specification on Google Bookmark Solid-State Lighting: Text-Alternative Version: LED Site

331

COST EFFECTIVENESS OF LONG LIFE INCANDESCENT LAMPS AND ENERGY BUTTONS  

E-Print Network (OSTI)

certain whether the electrical power is off or on, he may beof light. The electrical input (power, voltage and current)

Verderber, Rudy

2013-01-01T23:59:59.000Z

332

Smart Spaces Industry/Academia Day | 02.08.2011 | Page 1 Dr. M.A.Stough | Research Solid-State Lighting  

E-Print Network (OSTI)

60 watt bulb with an equivalent lumens LED white light bulb for usage of 50,000 hours leads delay). As is increased, less power goes to incandescent bulb and brightness is reduced. Most LED lamps dimmers. Often on the LED bulb application notes or on the lamp's manufacturer web sites

LĂĽ, James Jian-Qiang

333

Research on Active Power Factor Correction of the Electronic Ballast for High-Pressure Sodium Lamps Based on L6563  

Science Conference Proceedings (OSTI)

In the recent years, there has been a growing interest in the design of high-pressure sodium lamp electronic ballast. Two measures are proposed to improve the power factor of high-pressure sodium lamp electronic ballasts from the definition of harmonic ... Keywords: high-pressure sodium lamps, electronic ballast, active power factor correction, L6563

Sun Jing

2010-06-01T23:59:59.000Z

334

Spectroscopy on Metal-Halide Lamps under Varying Gravity Conditions  

E-Print Network (OSTI)

orange street lighting), which has a slightly lower discharge conversion efficiency, but the 589 nm line. They are mainly used for applications where a high light output is desired; examples are shop lighting, street. Haverlag Copromotor: dr.ir. W.W. Stoffels Copyright c 2008 by A.J. Flikweert This research was financially

Eindhoven, Technische Universiteit

335

Data:B73fdacd-eca4-49cb-bc90-c97865eb18d5 | Open Energy Information  

Open Energy Info (EERE)

date: 20120101 End date if known: Rate name: STREET LIGHTING-ASSOCIATION-OWNED: LED: 100 Watt Equivalent per Lamp Sector: Lighting Description: LED 100 Watt Equivalent per...

336

Data:2afd6900-e974-4471-961f-d979524856a3 | Open Energy Information  

Open Energy Info (EERE)

date: 20120101 End date if known: Rate name: STREET LIGHTING-ASSOCIATION-OWNED: LED: 250 Watt Equivalent per Lamp Sector: Lighting Description: LED 250 Watt Equivalent per...

337

U.S. Energy Information Administration (EIA) - Source  

Gasoline and Diesel Fuel Update (EIA)

of incandescent bulbs with more efficient compact fluorescent lighting and light-emitting diode (LED) lamps. Among electric end-use services in the residential sector,...

338

Data:Ad01c9a3-4c67-42d5-82c2-64f1a4bbe60c | Open Energy Information  

Open Energy Info (EERE)

HPS 100w Sector: Lighting Description: Applicable only to outdoor lighting by ballast operated vapor lamp fixtures and poles conforming to Cooperative specifications....

339

Data:72b22d28-179d-417f-83f5-80f86e12a95a | Open Energy Information  

Open Energy Info (EERE)

Sector: Lighting Description: Applicable for dusk to dawn lighting service by means of ballast operated lamp fixtures on a suitable wood pole. The service includes all electrical...

340

Data:05596484-9033-48bc-bb94-d54ded624907 | Open Energy Information  

Open Energy Info (EERE)

HPS 400w Sector: Lighting Description: Applicable only to outdoor lighting by ballast operated vapor lamp fixtures and poles conforming to Cooperative specifications....

Note: This page contains sample records for the topic "lamp sector lighting" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Data:5eae05f3-0992-4df8-9a69-3a7a990ad635 | Open Energy Information  

Open Energy Info (EERE)

Sector: Lighting Description: Applicable for dusk to dawn lighting service by means of ballast operated lamp fixtures on a suitable wood pole. The service includes all electrical...

342

Data:A7cdaff8-e308-4a6b-90ac-720914114d3e | Open Energy Information  

Open Energy Info (EERE)

MH 400w Sector: Lighting Description: Applicable only to outdoor lighting by ballast operated vapor lamp fixtures and poles conforming to Cooperative specifications....

343

Data:445d426e-8503-4331-82d7-db5b8d07dd8f | Open Energy Information  

Open Energy Info (EERE)

MV without Pole) Sector: Lighting Description: Applicable only to outdoor lighting by ballast operated vapor lamp fixtures, either Mercury Vapor, Pressure Sodium, or Metal Halide....

344

Data:81081762-3842-4bb7-9158-759d2c2b4c6f | Open Energy Information  

Open Energy Info (EERE)

MH 175w Sector: Lighting Description: Applicable only to outdoor lighting by ballast operated vapor lamp fixtures and poles conforming to Cooperative specifications....

345

Data:65c9cfff-dc25-4b05-9ee9-d5d70bb2e905 | Open Energy Information  

Open Energy Info (EERE)

HPS without Pole) Sector: Lighting Description: Applicable only to outdoor lighting by ballast operated vapor lamp fixtures, either Mercury Vapor, Pressure Sodium, or Metal Halide....

346

Data:2133e8ac-5d0e-4182-8646-085b999228f5 | Open Energy Information  

Open Energy Info (EERE)

MH 250w Sector: Lighting Description: Applicable only to outdoor lighting by ballast operated vapor lamp fixtures and poles conforming to Cooperative specifications....

347

Data:847d6419-dcc8-4499-bc82-52909c8067ca | Open Energy Information  

Open Energy Info (EERE)

HPS without Pole) Sector: Lighting Description: Applicable only to outdoor lighting by ballast operated vapor lamp fixtures, either Mercury Vapor, Pressure Sodium, or Metal Halide....

348

Data:3df24d6a-96c8-4021-a306-676834ce4ff6 | Open Energy Information  

Open Energy Info (EERE)

Sector: Lighting Description: Applicable for dusk to dawn lighting service by means of ballast operated lamp fixtures on a suitable wood pole. The service includes all electrical...

349

Data:35e70786-134f-4c6a-8b9a-44f514d7682f | Open Energy Information  

Open Energy Info (EERE)

LS (250 W HPS-Dir) Sector: Lighting Description: Applicable to outdoor lighting by ballast-operated vapor lamp fixtures and poles conforming to Cooperative specifications....

350

Data:4383f60e-b140-4087-b642-a716217c9927 | Open Energy Information  

Open Energy Info (EERE)

W MV with Pole) Sector: Lighting Description: Applicable only to outdoor lighting by ballast operated vapor lamp fixtures, either Mercury Vapor, Pressure Sodium, or Metal Halide....

351

Data:A36f0169-8028-4fc9-954c-071b63d0811c | Open Energy Information  

Open Energy Info (EERE)

W HPS with Pole) Sector: Lighting Description: Applicable only to outdoor lighting by ballast operated vapor lamp fixtures, either Mercury Vapor, Pressure Sodium, or Metal Halide....

352

Data:4b7a924c-0946-49cc-b6f6-c59af19db4d4 | Open Energy Information  

Open Energy Info (EERE)

High Pressure Sodium Sector: Lighting Description: Applicable to outdoor lighting by ballast operated vapor lamp fixtures attached to poles conforming to the City's...

353

Data:468fda37-fb88-408b-a804-bcdacd6f23aa | Open Energy Information  

Open Energy Info (EERE)

W HPS with Pole) Sector: Lighting Description: Applicable only to outdoor lighting by ballast operated vapor lamp fixtures, either Mercury Vapor, Pressure Sodium, or Metal Halide....

354

Data:04ec1c93-4365-44d1-b890-9b179b25a1d6 | Open Energy Information  

Open Energy Info (EERE)

Sector: Lighting Description: Applicable for dusk to dawn lighting service by means of ballast operated lamp fixtures on a suitable wood pole. The service includes all electrical...

355

Data:3e340fd3-e49a-44bd-8c4a-16fa47debe51 | Open Energy Information  

Open Energy Info (EERE)

HPS without Pole) Sector: Lighting Description: Applicable only to outdoor lighting by ballast operated vapor lamp fixtures, either Mercury Vapor, Pressure Sodium, or Metal Halide....

356

Data:16306243-470d-45c7-9a2d-9644a4f91c72 | Open Energy Information  

Open Energy Info (EERE)

HPS 1000w Sector: Lighting Description: Applicable only to outdoor lighting by ballast operated vapor lamp fixtures and poles conforming to Cooperative specifications....

357

Data:Dec830b0-ab8d-463e-b5de-2f0f2d096fbc | Open Energy Information  

Open Energy Info (EERE)

LS (100 W HPS) Sector: Lighting Description: Applicable to outdoor lighting by ballast-operated vapor lamp fixtures and poles conforming to Cooperative specifications....

358

Data:9f63edce-619a-4ae5-acbc-06d752f31d2d | Open Energy Information  

Open Energy Info (EERE)

HPS without Pole) Sector: Lighting Description: Applicable only to outdoor lighting by ballast operated vapor lamp fixtures, either Mercury Vapor, Pressure Sodium, or Metal Halide....

359

Data:A97d4360-0ad8-4d10-ad37-23a878a1e3f7 | Open Energy Information  

Open Energy Info (EERE)

MV without Pole) Sector: Lighting Description: Applicable only to outdoor lighting by ballast operated vapor lamp fixtures, either Mercury Vapor, Pressure Sodium, or Metal Halide....

360

Data:D02e240e-0b03-4a55-a0cb-2fb21d990680 | Open Energy Information  

Open Energy Info (EERE)

W HPS with Pole) Sector: Lighting Description: Applicable only to outdoor lighting by ballast operated vapor lamp fixtures, either Mercury Vapor, Pressure Sodium, or Metal Halide....

Note: This page contains sample records for the topic "lamp sector lighting" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Data:D6bbc514-9a53-4164-8390-3bb6bb13e7bf | Open Energy Information  

Open Energy Info (EERE)

LS (250 W HPS-CH) Sector: Lighting Description: Applicable to outdoor lighting by ballast-operated vapor lamp fixtures and poles conforming to Cooperative specifications....

362

Data:D7f0a1b2-0ae3-4077-8b0d-bb3e773bfcdf | Open Energy Information  

Open Energy Info (EERE)

LS (175 W MHMV) Sector: Lighting Description: Applicable to outdoor lighting by ballast-operated vapor lamp fixtures and poles conforming to Cooperative specifications....

363

Data:1c28e1b7-7ac6-4b2e-a575-2a7647398603 | Open Energy Information  

Open Energy Info (EERE)

Sector: Lighting Description: Applicable for dusk to dawn lighting service by means of ballast operated lamp fixtures on a suitable wood pole. The service includes all electrical...

364

Data:4df36a5c-1301-4c53-9017-92328028cfe4 | Open Energy Information  

Open Energy Info (EERE)

MV without Pole) Sector: Lighting Description: Applicable only to outdoor lighting by ballast operated vapor lamp fixtures, either Mercury Vapor, Pressure Sodium, or Metal Halide....

365

Data:Bf2519c7-759c-4e83-80ef-406e0a5f00d9 | Open Energy Information  

Open Energy Info (EERE)

MHHPS 400 W) Sector: Lighting Description: Applicable only to outdoor lighting by ballast operated vapor lamp fixtures, either Mercury Vapor, Pressure Sodium, or Metal Halide....

366

Data:87b747db-a60a-468b-9521-eb9546bc74ad | Open Energy Information  

Open Energy Info (EERE)

HPS 150w Sector: Lighting Description: Applicable only to outdoor lighting by ballast operated vapor lamp fixtures and poles conforming to Cooperative specifications....

367

Data:D887d73e-2188-4935-b127-cdc12e538882 | Open Energy Information  

Open Energy Info (EERE)

MH 1000w Sector: Lighting Description: Applicable only to outdoor lighting by ballast operated vapor lamp fixtures and poles conforming to Cooperative specifications....

368

Data:820e509f-d2b1-4345-bf6d-240d05d98b17 | Open Energy Information  

Open Energy Info (EERE)

HPSMV with Pole) Sector: Lighting Description: Applicable only to outdoor lighting by ballast operated vapor lamp fixtures, either Mercury Vapor, Pressure Sodium, or Metal Halide....

369

Data:Ddd53fc0-45e3-44e7-9e5a-d7e0371afc29 | Open Energy Information  

Open Energy Info (EERE)

Sector: Lighting Description: Applicable for dusk to dawn lighting service by means of ballast operated lamp fixtures on a suitable wood pole. The service includes all electrical...

370

Energy saving system for office lighting by using PSO and ZigBee network  

Science Conference Proceedings (OSTI)

In order to reduce the amount of wasted energy in office lighting and provide a major contribution to lowering overall energy consumption, we are developing a new energy saving system for office lighting by using adjustable lamp, ZigBee Wireless Sensor ... Keywords: PSO, energy saving system, office lighting, wireless sensor network, zigbee

Wa Si; Harutoshi Ogai; Tansheng Li; Masatoshi Ogawa; Katsumi Hirai; Hidehiro Takahashi

2010-12-01T23:59:59.000Z

371

Survey and Forecast of Marketplace Supply and Demand for Energy-Efficient Lighting Products  

Science Conference Proceedings (OSTI)

Utility incentive programs have placed significant demands on the suppliers of certain types of energy-efficient lighting products--particularly compact fluorescent lamps and electronic ballasts. Two major federal programs may soon place even greater demands on the lighting industry. This report assesses the program-induced demand for efficient lighting products and their likely near-term supply.

1992-12-01T23:59:59.000Z

372

A dimmable (1000:1 range) fluorescent ballast for instrument panel lighting  

SciTech Connect

A 1000:1 wide range continuously dimmable ballast is designed for fluorescent lighting of aircraft instrument panels. High voltage, low energy, 800 Hz starting pulses reliably start the lamps at all light level settings. The starting pulses alone produce the illumination at the minimum light control setting.

Lauritzen, P.O.; Jorgensen, J.A.; Meyer, S.D.; Osborn, J.G.

1983-01-01T23:59:59.000Z

373

Recent Major Improvements to the ALS Sector 5 Macromolecular Crystallography Beamlines  

E-Print Network (OSTI)

Recent major improvements to the ALS Sector 5 Macromolecularthe Advanced Light Source (ALS)) was initially conceivedwhich together formed the ALS Macromolecular Crystallography

2008-01-01T23:59:59.000Z

374

Public Sector Electric Efficiency Programs | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Public Sector Electric Efficiency Programs Public Sector Electric Efficiency Programs Public Sector Electric Efficiency Programs < Back Eligibility Fed. Government Institutional Local Government Schools State Government Savings Category Heating & Cooling Commercial Heating & Cooling Heating Cooling Other Construction Heat Pumps Appliances & Electronics Commercial Lighting Lighting Manufacturing Water Heating Maximum Rebate $300,000 per location Total incentive may not exceed 75% of project cost (equipment + labor) or 100% of incremental measure cost Program Info Funding Source Illinois Energy Efficiency Portfolio Standard (EEPS) surcharge for ComEd, Ameren subsidiary customers Start Date 06/01/2008 State Illinois Program Type State Rebate Program Rebate Amount Standard Incentive Program: Varies by technology

375

Public Sector New Construction and Retrofit Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Public Sector New Construction and Retrofit Program Public Sector New Construction and Retrofit Program Public Sector New Construction and Retrofit Program < Back Eligibility Fed. Government Institutional Local Government Schools State Government Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Commercial Weatherization Sealing Your Home Cooling Construction Design & Remodeling Appliances & Electronics Ventilation Heat Pumps Commercial Lighting Lighting Manufacturing Insulation Water Heating Windows, Doors, & Skylights Maximum Rebate Bonus maximum: $100,000 All incentives: $2.50/sq. ft. (base plus bonus), $300,000, 75% of project costs, and 100% of incremental costs Program Info Funding Source Illinois Energy Efficiency Portfolio Standard (EEPS) surcharge for Ameren,

376

Energy Efficiency Financing for Public Sector Projects (California) |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Efficiency Financing for Public Sector Projects (California) Energy Efficiency Financing for Public Sector Projects (California) Energy Efficiency Financing for Public Sector Projects (California) < Back Eligibility Institutional Local Government Schools Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Commercial Weatherization Cooling Other Heat Pumps Appliances & Electronics Commercial Lighting Lighting Manufacturing Buying & Making Electricity Energy Sources Solar Wind Maximum Rebate $3 million Program Info State California Program Type State Loan Program Provider California Energy Commission Cities, counties, public care institutions, public hospitals, public schools and colleges, and special districts in California can apply for low-interest loans from the California Energy Commission for energy

377

Lamp system with conditioned water coolant and diffuse reflector of polytetrafluorethylene(PTFE)  

SciTech Connect

A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.

Zapata, Luis E. (Livermore, CA); Hackel, Lloyd (Livermore, CA)

1999-01-01T23:59:59.000Z

378

Lamp system with conditioned water coolant and diffuse reflector of polytetrafluorethylene(PTFE)  

SciTech Connect

A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO{sub 2}) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.

Zapata, L.E.; Hackel, L.

1999-10-26T23:59:59.000Z

379

Identification of lamp ballasts containing PCBs. Revised edition. Report no. EPS 2/CC/2  

SciTech Connect

Fluorescent lamp ballast capacitors are among the products that may contain polychlorinated biphenyls (PCBs). Questions about lamp ballasts concern the potential for leakage, the risk of heating and exploding, how to identify a ballast which contains PCBs, and the risk to human health. This study identifies those ballasts containing PCB-filled capacitors; the domestic and foreign manufacturers of PCB-containing ballasts; the total quantity of PCBs used in ballasts; and any potential problems. The study does not identify the risks of human health arising from the use of PCB-ballasts in fluorescent lamps.

1991-01-01T23:59:59.000Z

380

Buildings sector demand-side efficiency technology summaries  

SciTech Connect

This report provides descriptions of the following energy efficiency technologies: energy management systems; electronic fluorescent ballasts; compact fluorescent lamps; lighting controls; room air conditioners; high albedo materials, coatings and paints; solar domestic water heaters; heat pump water heaters; energy-efficient motors; adjustable-speed drives; energy-efficient refrigerators; daylight control glazing; insulating glazing; solar control glazing; switchable glazing; tree planting; and advanced insulation. For each technology, the report provides a description of performance characteristics, consumer utility, development status, technology standards, equipment cost, installation, maintenance, conservation programs, and environmental impacts.

Koomey, J.G.; Johnson, F.X.; Schuman, J. [and others

1994-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "lamp sector lighting" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Louisville Private Sector  

NLE Websites -- All DOE Office Websites (Extended Search)

Private Sector Attendees Private Sector Attendees ENERGY STAR Kick-off Meeting December 2007 5/3rd Bank Al J Schneider Company (The Galt House East) Baptist Hospital East Brown - Forman Building Owner and Managers Association (BOMA) Louisville CB Richard Ellis Commercial Real Estate Women (CREW) Louisville Cushman Wakefield General Electric Company Golden Foods Greater Louisville Chapter of International Facility Management Association (IFMA) Hines Humana, Inc Institute of Real Estate Management (IREM) Kentucky Chapter Jewish Hospital & St Mary's Healthcare Kentucky Chapter, Certified Commercial Investment Managers (CCIM) Kentucky Governor's Office of Energy Policy Kentucky Society of Health Care Engineers Kindred Health Care Louisville Air Pollution Control Board

382

A high-efficiency indirect lighting system utilizing the solar 1000 sulfur lamp  

E-Print Network (OSTI)

and Renewable Energy, Office of Building Technology, State andand Renewable Energy, Office of Building Technology, State and

Siminovitch, Michael; Gould, C.; Page, E.

1997-01-01T23:59:59.000Z

383

Westinghouse and Fuzhou Permitted to Restart Distribution of Light Bulb  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Westinghouse and Fuzhou Permitted to Restart Distribution of Light Westinghouse and Fuzhou Permitted to Restart Distribution of Light Bulb Products Westinghouse and Fuzhou Permitted to Restart Distribution of Light Bulb Products August 6, 2010 - 4:26pm Addthis The Department has issued Notices of Allowance to Westinghouse Lighting Corporation and Fuzhou Sunlight Lighting Electrical Appliance Company determining, based on corrected test data provided by Westinghouse, that the incandescent reflector lamps listed below are compliant with the federal energy conservation standard and may be sold in the United States. These 11 Westinghouse brand lamps, usually used in recessed light fixtures, correspond to 7 basic models, which are manufactured in China by Fuzhou. DOE had previously issued Notices requiring Fuzhou and Westinghouse to

384

Miniature UV lamp excited by subnanosecond voltage pulses  

SciTech Connect

Energy, time, and spectral characteristics of emission of the second positive system of N{sub 2} molecules in gaseous nitrogen, Ar - N{sub 2} mixture, and air are investigated. An FPG-10 generator with voltage pulse FWHM of 200 and 400 ps and matched-load amplitudes of 14 and 6 kV, respectively, is used to excite gases. It is shown that excitation can be performed in two regimes using this generator. In the first regime a diffuse discharge is formed at atmospheric pressure, which opens ways to design miniature nanosecond UV lamps. A diffuse discharge is formed due to the generation of runaway electrons, with the aid of electrodes having a small radius of curvature and voltage pulses with a sharp leading edge. In the second regime an elevated average radiation power is obtained under excitation by a barrier discharge. However, the operating pressure is lower in this case, and the sizes of the emitting region and the UV pulse width significantly increase. (laser applications and other topics in quantum electronics)

Erofeev, M V; Baksht, E Kh; Tarasenko, Viktor F; Shut'ko, Yu V [Institute of High Current Electronics, Siberian Branch, Russian Academy of Sciences, Tomsk (Russian Federation)

2010-08-27T23:59:59.000Z

385

L Prize Competition Winner: 60W Incandescent Replacement Lamp  

NLE Websites -- All DOE Office Websites (Extended Search)

Prize Partners 14 15 Field Assessments: Retail Platte River Power Authority DTE Energy SMUD 16 Additional Opportunities: GATEWAY Demonstrations of LED Outdoor Lighting Reports...

386

COST EFFECTIVENESS OF LONG LIFE INCANDESCENT LAMPS AND ENERGY BUTTONS  

E-Print Network (OSTI)

placed into light bulb sockets (Edison sockets) and the lampbe inserted into the same Edison type socket that is usedto injury. In addition, Edison sockets that are hori~

Verderber, Rudy

2013-01-01T23:59:59.000Z

387

EXC-12-0007 - In the Matter of Tailored Lighting, Inc. | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

EXC-12-0007 - In the Matter of Tailored Lighting, Inc. EXC-12-0007 - In the Matter of Tailored Lighting, Inc. EXC-12-0007 - In the Matter of Tailored Lighting, Inc. On October 23, 2012, OHA issued a decision considering an Application for Exception filed by Tailored Lighting, Inc. (TLI) for relief from the provisions of 10 C.F.R. Part 430, Energy Conservation Program: Energy Conservation Standards and Test Procedures for General Service Fluorescent Lamps and Incandescent Reflector Lamps (Lighting Efficiency Standards). In its exception request, TLI requests exception relief for its principal product, a PAR-shaped daylight incandescent reflector lamp known as the SoLux PAR. The company maintains that it has been unable to develop a more efficient alternative that offers the same utility as the SoLux PAR and, as

388

EXC-12-0007 - In the Matter of Tailored Lighting, Inc. | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

07 - In the Matter of Tailored Lighting, Inc. 07 - In the Matter of Tailored Lighting, Inc. EXC-12-0007 - In the Matter of Tailored Lighting, Inc. On October 23, 2012, OHA issued a decision considering an Application for Exception filed by Tailored Lighting, Inc. (TLI) for relief from the provisions of 10 C.F.R. Part 430, Energy Conservation Program: Energy Conservation Standards and Test Procedures for General Service Fluorescent Lamps and Incandescent Reflector Lamps (Lighting Efficiency Standards). In its exception request, TLI requests exception relief for its principal product, a PAR-shaped daylight incandescent reflector lamp known as the SoLux PAR. The company maintains that it has been unable to develop a more efficient alternative that offers the same utility as the SoLux PAR and, as a result, will suffer serious hardship, gross inequity, and an unfair

389

On the Brightness of the Thomson Lamp: A Prolegomenon to Quantum Recursion Theory  

Science Conference Proceedings (OSTI)

Some physical aspects related to the limit operations of the Thomson lamp are discussed. Regardless of the formally unbounded and even infinite number of "steps" involved, the physical limit has an operational meaning in agreement with the Abel sums ...

Karl Svozil

2009-09-01T23:59:59.000Z

390

Commercial Sector Demand Module  

Reports and Publications (EIA)

Documents the objectives, analytical approach and development of the National Energy Modeling System (NEMS) Commercial Sector Demand Module. The report catalogues and describes the model assumptions, computational methodology, parameter estimation techniques, model source code, and forecast results generated through the synthesis and scenario development based on these components.

Kevin Jarzomski

2012-11-15T23:59:59.000Z

391

Commercial Sector Demand Module  

Reports and Publications (EIA)

Documents the objectives, analytical approach and development of the National Energy Modeling System (NEMS) Commercial Sector Demand Module. The report catalogues and describes the model assumptions, computational methodology, parameter estimation techniques, model source code, and forecast results generated through the synthesis and scenario development based on these components.

Kevin Jarzomski

2013-10-10T23:59:59.000Z

392

Making Africa's Power Sector Sustainable: An Analysis of Power Sector  

Open Energy Info (EERE)

Making Africa's Power Sector Sustainable: An Analysis of Power Sector Making Africa's Power Sector Sustainable: An Analysis of Power Sector Reforms in Africa Jump to: navigation, search Tool Summary Name: Making Africa's Power Sector Sustainable: An Analysis of Power Sector Reforms in Africa Agency/Company /Organization: United Nations Environment Programme, United Nations Economic Commission for Africa Sector: Energy Topics: Market analysis, Policies/deployment programs, Co-benefits assessment, - Energy Access, - Environmental and Biodiversity Resource Type: Guide/manual, Lessons learned/best practices Website: www.uneca.org/eca_programmes/nrid/pubs/powersectorreport.pdf UN Region: Eastern Africa References: Making Africa's Power Sector Sustainable: An Analysis of Power Sector Reforms in Africa[1] Overview "This study assesses the socio-economic and environmental impacts of power

393

Sector 4 Publications  

NLE Websites -- All DOE Office Websites (Extended Search)

J. van Lierop, Appl. Phys. Lett. 99, 262501 (2011). "Note: A portable, light-emitting diode-based ruby fluorescence spectrometer for high-pressure calibration," Yejun...

394

Analysis of Minimum Efficiency Performance Standards for Residential General Service Lighting in Chile  

Science Conference Proceedings (OSTI)

Minimum Efficiency Performance Standards (MEPS) have been chosen as part of Chile's national energy efficiency action plan. As a first MEPS, the Ministry of Energy has decided to focus on a regulation for lighting that would ban the sale of inefficient bulbs, effectively phasing out the use of incandescent lamps. Following major economies such as the US (EISA, 2007) , the EU (Ecodesign, 2009) and Australia (AS/NZS, 2008) who planned a phase out based on minimum efficacy requirements, the Ministry of Energy has undertaken the impact analysis of a MEPS on the residential lighting sector. Fundacion Chile (FC) and Lawrence Berkeley National Laboratory (LBNL) collaborated with the Ministry of Energy and the National Energy Efficiency Program (Programa Pais de Eficiencia Energetica, or PPEE) in order to produce a techno-economic analysis of this future policy measure. LBNL has developed for CLASP (CLASP, 2007) a spreadsheet tool called the Policy Analysis Modeling System (PAMS) that allows for evaluation of costs and benefits at the consumer level but also a wide range of impacts at the national level, such as energy savings, net present value of savings, greenhouse gas (CO2) emission reductions and avoided capacity generation due to a specific policy. Because historically Chile has followed European schemes in energy efficiency programs (test procedures, labelling program definitions), we take the Ecodesign commission regulation No 244/2009 as a starting point when defining our phase out program, which means a tiered phase out based on minimum efficacy per lumen category. The following data were collected in order to perform the techno-economic analysis: (1) Retail prices, efficiency and wattage category in the current market, (2) Usage data (hours of lamp use per day), and (3) Stock data, penetration of efficient lamps in the market. Using these data, PAMS calculates the costs and benefits of efficiency standards from two distinct but related perspectives: (1) The Life-Cycle Cost (LCC) calculation examines costs and benefits from the perspective of the individual household; and (2) The National Perspective projects the total national costs and benefits including both financial benefits, and energy savings and environmental benefits. The national perspective calculations are called the National Energy Savings (NES) and the Net Present Value (NPV) calculations. PAMS also calculate total emission mitigation and avoided generation capacity. This paper describes the data and methodology used in PAMS and presents the results of the proposed phase out of incandescent bulbs in Chile.

Letschert, Virginie E.; McNeil, Michael A.; Leiva Ibanez, Francisco Humberto; Ruiz, Ana Maria; Pavon, Mariana; Hall, Stephen

2011-06-01T23:59:59.000Z

395

Review Articles of Overview of Solid-State Lighting  

NLE Websites -- All DOE Office Websites (Extended Search)

REVIEW ARTICLES REVIEW ARTICLES Solid-state lighting is an exciting and rapidly moving area of research and development. For the latest developments, please see the Science and Business News section of this website. Here, we have compiled a list of review articles covering various aspects of solid-state lighting science, technology and engineering. · June 2004. Nanoscience and solid-state lighting, presented by George Craford of Lumileds at the DOE Nanosummit, covers technology background and status, applications, technical challenges, and nanotechnology approaches. · May 2004. A detailed review, in IEEE Circuits and Devices, of the various lamp, chip and materials design choices that will be faced as solid-state lighting technology improves to the point of meeting long-term roadmap targets. This article, by Jeff Tsao at Sandia National Laboratories, is titled Solid-state lighting: lamps, chips and materials for tomorrow.

396

L Prize Competition Winner 60W Incandesent Replacement Lamp Update  

NLE Websites -- All DOE Office Websites (Extended Search)

soon. --Senator Jeff Bingaman, D-NM What's the Buzz? - Would You Buy A 60 Light Bulb That Lasts 20 Years? -game-changing technology L Prize Helps Federal Purchasers:...

397

Lansing Board of Water and Light - Hometown Energy Savers® Residential  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Savers® Savers® Residential Rebates Lansing Board of Water and Light - Hometown Energy Savers® Residential Rebates < Back Eligibility Low-Income Residential Multi-Family Residential Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Manufacturing Appliances & Electronics Construction Heating Heat Pumps Commercial Lighting Lighting Water Heating Other Program Info State Michigan Program Type Utility Rebate Program Rebate Amount Small Business Direct Install Program: No cost or purchase necessary for participation Custom $0.08/kWh Commercial Cooking Equipment: Varies Commercial Refrigeration Equipment: Varies Lighting Compact Fluorescent Lamps: $1.50-$8 Compact Fluorescent Lamp Fixtures: $20 LED Lamps: $5-$15 LED Fixtures: $20 LED Exit Signs: $12.50

398

Performance of electronic ballasts and other new lighting equipment. Final report  

SciTech Connect

This study discusses parameters for selecting the most suitable auxiliary lighting device to operate and control gas-discharge lamps. The devices tested in this study include solid-state fluorescent and high-intensity discharge (HID) ballasts; current limiters; and dynamic lighting controls. They have been evaluated in combination with the standard 40-W, F-40, T-12, rapid-start, cool-white fluorescent lamps. Solid-state ballast performance varied widely- from 68 to 79 lumens per watt (lm/W) in efficacy and from 0.83 to 0.98 in ballast factor. System efficacy was up to 26% higher than standard core-coil ballast efficacy. Current limiters used with standard core-coil ballast reduce light output and input power by 30 to 50% and may be suitable as retrofit devices to reduce light in overilluminated spaces. When operated at a constant lamp wall temperature, these devices either maintain or reduce system efficacy.

Verderber, R.R.; Morse, O.

1986-03-01T23:59:59.000Z

399

GLASS AND GLASS-DERIVATIVE SEALS FOR USE IN ENERGY-EFFICIENT FUEL CELLS AND LAMPS  

DOE Green Energy (OSTI)

As the project approaches the end of the first year, the materials screening components of the work are ahead of schedule, while all other tasks are on schedule. For solid oxide fuel cells (SOFC), a series of 16 sealing glasses have been prepared and characterized. Traditional melting was used to prepare all of the glasses, and the sol-gel approach has been used to prepare some of the glasses as well as other compositions that might be viable because of the low processing temperatures afforded by the sol-gel method. The glass characterization included measurements of the viscosity and thermal expansion of the glasses, as well as the thermal expansion of the partly crystalline glass ceramics. In addition, the wetting and sintering behavior of all glasses has been measured, as well as the crystallization behavior. The time and temperature at which crystalline phases form from the glasses has been determined for all of the glasses. Each glass ceramic contains at least two crystalline phases, and most of the crystalline phases have been positively identified. Room temperature leak testing has been completed for all sealants, and experiments are in progress to determine the DC electrochemical degradation and degradation in wet hydrogen. The second component of the work, focused on seals for higher-temperature discharge lighting, has focused on determining the phase relations in the yttria--alumina--silica system at various silica levels. Again, traditional melting and sol-gel synthesis have been employed, and the sol-gel method was successful for preparing new phases that were discovered during the work. High temperature diffraction and annealing studies have clarified the phase relations for the samples studies, although additional work remains. Four new phases have been identified and synthesized in pure form, from which full structure solutions were obtained as well as the anisotropic thermal expansion for each phase. Functional testing of lamps are on on-going and will be analyzed during year 2 of the contract.

Scott Misture; Arun Varshneya; Matthew Hall; Sylvia DeCarr; Steve Bancheri

2004-08-15T23:59:59.000Z

400

Lighting Retrofit Workbook A PRACTICAL"HOW TO" GUIDE  

E-Print Network (OSTI)

comparison for incandescent, CFL, and LED exit signs Source Type Incandescent CFL LED Power 40 watts 10/year based on a comparison of a 40 W A-lamp, a 15 W CFL, and a 5W LED, 24 hours per day, 365 days a year output, etc. · Reduced maintenance and labor costs Improvements in lighting technologies have led

Diamond, Richard

Note: This page contains sample records for the topic "lamp sector lighting" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Florida house aglow with lighting retrofit  

SciTech Connect

In a residential lighting retrofit, how much energy can be saved with current technology? The Florida Solar Energy Center decided to find out by retrofitting every lamp in a Miami home. Most lighting studies focus on average lighting energy use or on how much energy can be saved by retrofitting large numbers of homes. However, the Florida Solar Energy Center (FSEC) was interested in finding out how much lighting energy we could save in a single house. One house with high utility bills and extensive interior lighting was picked, throughly monitored, and retrofitted every light possible. The study also helped determine what sort of monitoring is most useful, and how residents respond to efficient lighting. 1 fig., 2 tabs.

Parker, D.; Schrum, L.

1997-01-01T23:59:59.000Z

402

Proposing Measures of Flicker in the Low Frequencies for Lighting Applications  

Science Conference Proceedings (OSTI)

The IEEE Standards Working Group, IEEE P1789 'Recommending practices for modulating current in High Brightness LEDs for mitigating health risks to viewers' has been formed to advise the lighting industry, ANSI/NEMA, IEC, EnergyStar and other standards groups about the emerging concern of flicker in LED lighting. This paper intends to introduce new measures and definitions of lamp flicker in lighting. The discussion represents on-going work in IEEE P1789 that is vital to designing safe LED lamp drivers.

Lehman, Brad; Wilkins, Arnold; Berman, Sam; Poplawski, Michael E.; Miller, Naomi J.

2011-01-31T23:59:59.000Z

403

Private Sector Outreach and Partnerships  

Energy.gov (U.S. Department of Energy (DOE))

ISER’s partnerships with the private sector are a strength which has enabled the division to respond to the needs of the sector and the nation. The division’s domestic capabilities have been...

404

X-ray Methods in High-Intensity Discharges and Metal-Halide Lamps: X-ray Induced Fluorescence  

SciTech Connect

We describe the use of x-ray induced fluorescence to study metal-halide high-intensity discharge lamps and to measure equilibrium vapor pressures of metal-halide salts. The physical principles of metal-halide lamps, relevant aspects of x-ray-atom interactions, the experimental method using synchrotron radiation, and x-ray induced fluorescence measurements relevant to metal-halide lamps are covered.

Curry, John J.; Lapatovich, Walter P.; Henins, Albert (NIST)

2011-12-09T23:59:59.000Z

405

Phosphor blends for high-CRI fluorescent lamps  

DOE Patents (OSTI)

A phosphor blend comprises at least two phosphors each selected from one of the groups of phosphors that absorb UV electromagnetic radiation and emit in a region of visible light. The phosphor blend can be applied to a discharge gas radiation source to produce light sources having high color rendering index. A phosphor blend is advantageously includes the phosphor (Tb,Y,LuLa,Gd).sub.x(Al,Ga).sub.yO.sub.12:Ce.sup.3+, wherein x is in the range from about 2.8 to and including 3 and y is in the range from about 4 to and including 5.

Setlur, Anant Achyut (Niskayuna, NY); Srivastava, Alok Mani (Niskayuna, NY); Comanzo, Holly Ann (Niskayuna, NY); Manivannan, Venkatesan (Clifton Park, NY); Beers, William Winder (Chesterland, OH); Toth, Katalin (Pomaz, HU); Balazs, Laszlo D. (Budapest, HU)

2008-06-24T23:59:59.000Z

406

Determination of the cathode and anode voltage drops in high power low-pressure amalgam lamps  

Science Conference Proceedings (OSTI)

For the first time, cathode and anode drops of powerful low-pressure amalgam lamps were measured. The lamp discharge current is 3.2 A, discharge current frequency is 43 kHz, linear electric power is 2.4 W/cm. The method of determination of a cathode drop is based on the change of a lamp operating voltage at variation of the electrode filament current at constant discharge current. The total (cathode plus anode) drop of voltage was measured by other, independent ways. The maximum cathode fall is 10.8 V; the anode fall corresponding to the maximal cathode fall is 2.4 V. It is shown that in powerful low pressure amalgam lamps the anode fall makes a considerable contribution (in certain cases, the basic one) to heating of electrodes. Therefore, the anode fall cannot be neglected, at design an electrode and ballast of amalgam lamps with operating discharge current frequency of tens of kHz.

Vasilyak, L. M., E-mail: vasilyak@ihed.ras.ru [Russian Academy of Sciences, Joint Institute for High Temperatures (Russian Federation); Vasiliev, A. I., E-mail: vasiliev@npo.lit.ru; Kostyuchenko, S. V.; Sokolov, D. V.; Startsev, A. Yu. [Joint Stock Company NPO LIT (Russian Federation); Kudryavtsev, N. N. [Moscow Institute of Physics and Technology (State University) (Russian Federation)

2011-12-15T23:59:59.000Z

407

Consumer Light Bulb Changes: Briefing and Resources for Media and Retailers  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Briefing for Media and Retailers - Lighting eere.energy.gov Briefing for Media and Retailers - Lighting eere.energy.gov 1 Consumer Light Bulb Changes: Briefing and Resources for Media and Retailers Briefing for Media and Retailers - Lighting eere.energy.gov 2 * Briefing: - To schedule interviews, please contact DOE Public Affairs at 202-586-4940 * Terms: - Lumens: Commonly a measure of brightness (technically "luminous flux") - CFL: Compact Fluorescent Lamp: The curly fluorescent bulbs - LED: Light Emitting Diode: more recently emerging technology, also called "solid state lighting" as it is light produced by a solid-state (chip) device - General Service Incandescent Lamp: The most common residential light bulb in use, with a medium screw base, and a lumen range of 310 to 2,600 lumens

408

Assessment of costs and benefits of flexible and alternative fuel use in the U.S. transportation sector. Technical report fourteen: Market potential and impacts of alternative fuel use in light-duty vehicles -- A 2000/2010 analysis  

DOE Green Energy (OSTI)

In this report, estimates are provided of the potential, by 2010, to displace conventional light-duty vehicle motor fuels with alternative fuels--compressed natural gas (CNG), liquefied petroleum gas (LPG), methanol from natural gas, ethanol from grain and from cellulosic feedstocks, and electricity--and with replacement fuels such as oxygenates added to gasoline. The 2010 estimates include the motor fuel displacement resulting both from government programs (including the Clean Air Act and EPACT) and from potential market forces. This report also provides an estimate of motor fuel displacement by replacement and alterative fuels in the year 2000. However, in contrast to the 2010 estimates, the year 2000 estimate is restricted to an accounting of the effects of existing programs and regulations. 27 figs., 108 tabs.

NONE

1996-01-01T23:59:59.000Z

409

Black Carbon and Kerosene Lighting: An Opportunity for Rapid Action on Climate Change and Clean Energy for Development  

Science Conference Proceedings (OSTI)

Replacing inefficient kerosene lighting with electric lighting or other clean alternatives can rapidly achieve development and energy access goals, save money and reduce climate warming. Many of the 250 million households that lack reliable access to electricity rely on inefficient and dangerous simple wick lamps and other kerosene-fueled light sources, using 4 to 25 billion liters of kerosene annually to meet basic lighting needs. Kerosene costs can be a significant household expense and subsidies are expensive. New information on kerosene lamp emissions reveals that their climate impacts are substantial. Eliminating current annual black carbon emissions would provide a climate benefit equivalent to 5 gigatons of carbon dioxide reductions over the next 20 years. Robust and low-cost technologies for supplanting simple wick and other kerosene-fueled lamps exist and are easily distributed and scalable. Improving household lighting offers a low-cost opportunity to improve development, cool the climate and reduce costs.

Jacobson, Arne [Humboldt State Univ., MN (United States). Schatz Energy Research Center; Bond, Tami C. [Univ. of Illinois at Urbana-Champaign, IL (United States). Dept. of Civil and Environmental Engineering; Lam, Nicholoas L. [Univ. of California, Berkeley, CA (United States). Dept. of Environmental Health Sciences; Hultman, Nathan [The Brookings Institution, Washington, DC (United States)

2013-04-15T23:59:59.000Z

410

Glass and glass-derivative seals for use in energy-efficient fuel cells and lamps  

DOE Green Energy (OSTI)

For solid oxide fuel cells (SOFC), a series of 18 sealing glasses have been prepared and characterized. From the whole design space, several glasses were ''downselected'' and studied in detail to describe their behaviors in simulated fuel cell environments. One of the glasses was found to outperform all others, including the well-known G18 sealant developed at Pacific Northwest National Laboratory. The new glass composition showed lower bulk electrical conductivity, excellent sealing and wetting behavior when sealing under applied load, and qualitatively superior performance when exposed to wet hydrogen for 800 hours. Traditional melting was used to prepare all of the glasses that were studied in detail. The sol-gel approach was used to synthesize several compositions, but it was found that the glasses crystallized very rapidly during heating, precluding sealing. The glass characterization included measurements of the viscosity and thermal expansion of the glasses, as well as the thermal expansion of the partly crystalline glass ceramics. In addition, the wetting and sintering behavior of all glasses has been measured, as well as the crystallization behavior. The time and temperature at which crystalline phases form from the glasses has been determined for all of the glasses. Each glass ceramic contains at least two crystalline phases, and most of the crystalline phases have been positively identified. The body of fundamental data provides a platform for future developments for high temperature sealants, and the newly-developed glass compositions appear promising for large-scale testing. The second component of the work, focused on seals for higher-temperature discharge lighting, has focused on determining the phase relations in the yttria-alumina-silica system at various silica levels. Functional testing of one of the candidate sealants demonstrated that it performs well in current HID lighting applications. Further testing is required to evaluate its performance in next-generation lamps that operate at higher temperatures, but the baseline phase equilibria and crystallization behavior has been established for additional development. Again, traditional melting and sol-gel synthesis have been employed, and the sol-gel method was successful for preparing new phases that were discovered during the work. Four new phases have been identified and synthesized in pure form, from which full structure solutions were obtained as well as the anisotropic thermal expansion for each phase.

Scott Misture; Arun Varshineya; Matthew Hall; Sylvia DeCarr; Steve Bancheri

2005-07-28T23:59:59.000Z

411

Buildings Energy Data Book: 7.7 Efficiency Standards for Lighting  

Buildings Energy Data Book (EERE)

Efficiency Standards for Lighting Efficiency Standards for Lighting March 2011 7.7.2 Efficiency Standards for General Service Fluorescent Lamps Effective for products manufactured before July 14, 2012 Minimum Nominal Lamp Average Lamp Lamp Type (1) Wattage (W) Minimum CRI Efficacy (lm/W) Effective Date 4-Foot Medium Bipin >35 69 75.0 November 1, 1995 4-Foot Medium Bipin 45 75.0 November 1, 1995 2-Foot U-Shaped >35 69 68.0 November 1, 1995 2-Foot U-Shaped 45 64.0 November 1, 1995 8-Foot Slimline >65 69 80.0 May 1, 1994 8-Foot Slimline 45 80.0 May 1, 1994 8-Foot High Output >100 69 80.0 May 1, 1994 8-Foot High Output 45 80.0 May 1, 1994 Effective for products manufactured on or after July 14, 2012 Minimum Correlated Color Average Lamp Lamp Type Temperature (K) Efficacy (lm/W) 4-Foot Medium Bipin 89 4-Foot Medium Bipin 88 2-Foot U-Shaped

412

HIGH INTENSITY LIGHT SOURCES (Part II of Thesis)  

SciTech Connect

A stable carbon arc operated in controlled atmosphere is described. The arc was designed to serve as a light source during lifetime studies of the B/sup 2/ SIGMA state of the CN molecule. The CN radiation from the plasma of the arc was investigated and found to have a brightness temperature of 5500 icient laborato K at lambda 3883 A. This is considerably higher than an estimate of the value required for lifetime measurements. The stability of the carbon arc under various conditions is discussed. For successful lifetime measurements, the light source employed must have a high brightness temperature (intensity). A method for the determination of the brightness temperature of a light source at a specific wave length is described. The method was used for determining the brightness temperatures of some available light sources. Sodium, thallium, and mercury discharge lamps, a medium-pressure mercury arc lamp, and the carbon arc were studied. (auth)

Worden, E.F. Jr.

1958-10-01T23:59:59.000Z

413

Property:Sector | Open Energy Information  

Open Energy Info (EERE)

Property Property Edit with form History Facebook icon Twitter icon » Property:Sector Jump to: navigation, search This is a property of type Page. Subproperties This property has the following 1 subproperty: G Green Economy Toolbox Pages using the property "Sector" Showing 25 pages using this property. (previous 25) (next 25) 1 1 Solar Inc + Renewable Energy +, Solar + 1.5-ft Wave Flume Facility + Hydro + 10-ft Wave Flume Facility + Hydro + 11-ft Wave Flume Facility + Hydro + 12 Voltz Limited + Renewable Energy +, Solar +, Wind energy + 1366 Technologies + Solar + 1st Light Energy, Inc. + Solar + 2 2-ft Flume Facility + Hydro + 2008 Solar Technologies Market Report + Renewable Energy +, Solar +, Concentrating solar power +, ... 2010 Carbon Sequestration Atlas of the United States and Canada: Third Edition + Clean Fossil Energy +

414

L-Prize Competition Winner 60W Incandescent Replacement Lamp Update  

NLE Websites -- All DOE Office Websites (Extended Search)

Interagency Technology Deployment Working Group L Prize ® Competition Winner 60W Incandescent Replacement Lamp Update James E. Rannels, Senior Advisor L Prize Competition D&R International March 15, 2012 Cost of electricity 1 cent per kilowatt-hour The Washington Post, March 8, 2012 Page One 2 Cost of electricity 11 cents per kilowatt-hour The Washington Post, March 9, 2012 Page Two 3 What Is the L Prize? * Technology competition to spur innovation and exceptional performance * Created by Energy Independence and Security Act (EISA 2007) Sec. 655 * Two key lamp replacements: 60W Incandescent and PAR 38 Halogen * Future focus: 21 st Century Lamp * Cash prizes, federal purchasing, utility programs 4 Philips Wins First L Prize * August 3, 2011: Philips

415

L-Prize Competition Winner 60W Incandescent Replacement Lamp Update  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interagency Technology Deployment Working Group L Prize ® Competition Winner 60W Incandescent Replacement Lamp Update James E. Rannels, Senior Advisor L Prize Competition D&R International March 15, 2012 Cost of electricity 1 cent per kilowatt-hour The Washington Post, March 8, 2012 Page One 2 Cost of electricity 11 cents per kilowatt-hour The Washington Post, March 9, 2012 Page Two 3 What Is the L Prize? * Technology competition to spur innovation and exceptional performance * Created by Energy Independence and Security Act (EISA 2007) Sec. 655 * Two key lamp replacements: 60W Incandescent and PAR 38 Halogen * Future focus: 21 st Century Lamp * Cash prizes, federal purchasing, utility programs 4 Philips Wins First L Prize * August 3, 2011: Philips

416

Spectral distribution of dimmed HID lamps in a plant growth facility  

SciTech Connect

A commercial dimming ballast system for high intensity discharge (HID) lamps has been tested for use in plant growth chambers. The dimming ballast system can be controlled either manually at the dimming panel or by a d.c. voltage from a programmer or computer. Using the dimming system, photosynthetically active radiation can be continuously varied from about 200 to about 2000 ..mu..E m/sup -2/s/sup -1/. This paper shows the effects of dimming on the spectral intensity (400 to 750 nm) of three types of HID lamps measured individually and in combination to achieve a better spectral mix. The lamps used in this study were 400 w metal halide, mercury vapor and high pressure sodium.

Bingham, G.E.; Coyne, P.I.

1979-05-01T23:59:59.000Z

417

Solid-state lighting technology perspective.  

SciTech Connect

Solid-State Lighting (SSL) uses inorganic light-emitting diodes (LEDs) and organic light-emitting diodes (OLEDs) to convert electricity into light for illumination. SSL has the potential for enormous energy savings and accompanying environmental benefits if its promise of 50% (or greater) energy efficiencies can be achieved. This report provides a broad summary of the technologies that underlie SSL. The applications for SSL and potential impact on U.S. and world-wide energy consumption, and impact on the human visual experience are discussed. The properties of visible light and different technical metrics to characterize its properties are summarized. The many factors contributing to the capital and operating costs for SSL and traditional lighting sources (incandescent, fluorescent, and high-intensity discharge lamps) are discussed, with extrapolations for future SSL goals. The technologies underlying LEDs and OLEDs are also described, including current and possible alternative future technologies and some of the present limitations.

Tsao, Jeffrey Yeenien; Coltrin, Michael Elliott

2006-08-01T23:59:59.000Z

418

Multi-Photon Phosphor Feasibility Research: Advanced Light Source Development  

Science Conference Proceedings (OSTI)

Efficiencies of commercial light sources have reached a plateau at about 33 percent of the maximum possible, but these efficiencies will have to be doubled to achieve the energy savings in lighting needed in the future. One possibility is to develop phosphor materials for application to fluorescent lamps that emit two visible photons for each absorbed ultraviolet photon. Scientists discussed the possibility of developing such phosphor materials at a workshop held May 8 through May 10, 2001 in Peabody, Ma...

2001-08-09T23:59:59.000Z

419

Sector 6 Publications  

NLE Websites -- All DOE Office Websites (Extended Search)

0 0 2009 2008 2007 2006 2005 2004 2003 2002 2001 APS Pubs. Database Sector 6 Publications Publications 2013:(45) "Classical and quantum phase transitions revealed using transport and x-ray measurements," Arnab Banerjee, Ph.D.-Thesis, University of Chicago, 2013. "Charge transfer and multiple density waves in the rare earth tellurides," A. Banerjee, Yejun Feng, D.M. Silevitch, Jiyang Wang, J.C. Lang, H.-H. Kuo, I.R. Fisher, T.F. Rosenbaum, Phys. Rev. B 87, 155131 (2013). "Controlling Size-Induced Phase Transformations Using Chemically Designed Nanolaminates," Matt Beekman, Sabrina Disch, Sergei Rouvimov, Deepa Kasinathan, Klaus Koepernik, Helge Rosner, Paul Zschack, Wolfgang S. Neumann, David C. Johnson, Angew. Chem. Int. Ed. 52, 13211 (2013).

420

Sector 1 - Software  

NLE Websites -- All DOE Office Websites (Extended Search)

APS Software APS Software Scientists and researchers at the APS develop custom scientific software to help with acquisition and analysis of beamline data. Several packages are available for a variety of platforms and uses. Data Acquisition Motion control and data collection at the 1-BM and 1-ID beamlines are primarily executed using EPICS software. We also utilize SPEC, running through EPICS, for many experiments. Data Analysis Some of the programs used at Sector 1 to analyse 1-d and/or 2-d data sets are described: Fit2d, for viewing and analysing 2-dimensional data Igor, for analysis of small-angle scattering data Matlab, for strain/texture analysis and image analysis. GSAS/EXPGUI, for structural refinement of diffraction data. A comprehensive list of Powder Diffraction Software and Resources can be

Note: This page contains sample records for the topic "lamp sector lighting" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Louisville Private Sector Agenda  

NLE Websites -- All DOE Office Websites (Extended Search)

Thursday, December 13, 2007 Thursday, December 13, 2007 9:00 AM - 12:00 PM Agenda * Welcome and introductions from the Mayor (9:00-9:15) o The Mayor's energy and climate protection goals for Louisville o Request for private sector input for the upcoming public-private partnership to promote increased energy efficiency in buildings throughout the Louisville community o Highlights from the December 12 meeting of the ENERGY STAR Challenge implementation group o Introduction to Metro's Green Initiative and goals for today's session * Getting started with ENERGY STAR (9:15-10:00) o Introduction to the program and overview of ENERGY STAR resources o Kentucky and regional ENERGY STAR Partners and labeled buildings o Simple steps for energy savings o The benefits of energy savings

422

Energy Sector Market Analysis  

SciTech Connect

This paper presents the results of energy market analysis sponsored by the Department of Energy's (DOE) Weatherization and International Program (WIP) within the Office of Energy Efficiency and Renewable Energy (EERE). The analysis was conducted by a team of DOE laboratory experts from the National Renewable Energy Laboratory (NREL), Oak Ridge National Laboratory (ORNL), and Pacific Northwest National Laboratory (PNNL), with additional input from Lawrence Berkeley National Laboratory (LBNL). The analysis was structured to identify those markets and niches where government can create the biggest impact by informing management decisions in the private and public sectors. The analysis identifies those markets and niches where opportunities exist for increasing energy efficiency and renewable energy use.

Arent, D.; Benioff, R.; Mosey, G.; Bird, L.; Brown, J.; Brown, E.; Vimmerstedt, L.; Aabakken, J.; Parks, K.; Lapsa, M.; Davis, S.; Olszewski, M.; Cox, D.; McElhaney, K.; Hadley, S.; Hostick, D.; Nicholls, A.; McDonald, S.; Holloman, B.

2006-10-01T23:59:59.000Z

423

Electric Power Sector  

Gasoline and Diesel Fuel Update (EIA)

Electric Power Sector Electric Power Sector Hydroelectric Power (a) ............... 0.670 0.785 0.653 0.561 0.633 0.775 0.631 0.566 0.659 0.776 0.625 0.572 2.668 2.605 2.633 Wood Biomass (b) ........................ 0.048 0.043 0.052 0.046 0.045 0.039 0.051 0.052 0.055 0.049 0.060 0.054 0.190 0.187 0.218 Waste Biomass (c) ....................... 0.063 0.064 0.066 0.069 0.061 0.063 0.063 0.064 0.062 0.065 0.068 0.065 0.262 0.250 0.261 Wind ............................................. 0.376 0.361 0.253 0.377 0.428 0.461 0.315 0.400 0.417 0.461 0.340 0.424 1.368 1.604 1.641 Geothermal ................................. 0.036 0.037 0.038 0.039 0.041 0.041 0.041 0.042 0.041 0.040 0.041 0.042 0.149 0.164 0.165 Solar ............................................. 0.007 0.022 0.021 0.014 0.013 0.022 0.026 0.016 0.021 0.048 0.048 0.025 0.064

424

Program Program Organization Country Region Topic Sector Sector  

Open Energy Info (EERE)

Program Organization Country Region Topic Sector Sector Program Organization Country Region Topic Sector Sector Albania Enhancing Capacity for Low Emission Development Strategies EC LEDS Albania Enhancing Capacity for Low Emission Development Strategies EC LEDS United States Agency for International Development USAID United States Environmental Protection Agency United States Department of Energy United States Department of Agriculture United States Department of State Albania Southern Asia Low emission development planning LEDS Energy Land Climate Algeria Clean Technology Fund CTF Algeria Clean Technology Fund CTF African Development Bank Asian Development Bank European Bank for Reconstruction and Development EBRD Inter American Development Bank IDB World Bank Algeria South Eastern Asia Background analysis Finance Implementation

425

Data:19b93d1e-6c5c-45c3-b5a9-9d12606ab707 | Open Energy Information  

Open Energy Info (EERE)

New York (Utility Company) Effective date: 20101101 End date if known: Rate name: Street Light (250 Watt High Pressure Sodium Lamp) Sector: Commercial Description: Source...

426

Data:3b696695-22dd-4f07-95c1-5a249c3e18c4 | Open Energy Information  

Open Energy Info (EERE)

New York (Utility Company) Effective date: 20101101 End date if known: Rate name: Street Light (250 Watt Mercury Lamp) Sector: Commercial Description: Source or reference:...

427

Data:Eb081602-e6af-43e2-87c3-6fbbdc4028f9 | Open Energy Information  

Open Energy Info (EERE)

New York (Utility Company) Effective date: 20101101 End date if known: Rate name: Street Light (400 Watt Mercury Lamp) Sector: Commercial Description: Source or reference:...

428

Light-Light Scattering  

E-Print Network (OSTI)

For a long time, it is believed that the light by light scattering is described properly by the Lagrangian density obtained by Heisenberg and Euler. Here, we present a new calculation which is based on the modern field theory technique. It is found that the light-light scattering is completely different from the old expression. The reason is basically due to the unphysical condition (gauge condition) which was employed by the QED calcualtion of Karplus and Neumann. The correct cross section of light-light scattering at low energy of $(\\frac{\\omega}{m} \\ll 1)$ can be written as $ \\displaystyle{\\frac{d\\sigma}{d\\Omega}=\\frac{1}{(6\\pi)^2}\\frac{\\alpha^4} {(2\\omega)^2}(3+2\\cos^2\\theta +\\cos^4\\theta)}$.

Kanda, Naohiro

2011-01-01T23:59:59.000Z

429

Light-Light Scattering  

E-Print Network (OSTI)

For a long time, it is believed that the light by light scattering is described properly by the Lagrangian density obtained by Heisenberg and Euler. Here, we present a new calculation which is based on the modern field theory technique. It is found that the light-light scattering is completely different from the old expression. The reason is basically due to the unphysical condition (gauge condition) which was employed by the QED calcualtion of Karplus and Neumann. The correct cross section of light-light scattering at low energy of $(\\frac{\\omega}{m} \\ll 1)$ can be written as $ \\displaystyle{\\frac{d\\sigma}{d\\Omega}=\\frac{1}{(6\\pi)^2}\\frac{\\alpha^4} {(2\\omega)^2}(3+2\\cos^2\\theta +\\cos^4\\theta)}$.

Naohiro Kanda

2011-06-03T23:59:59.000Z

430

Sector 9 | Operations and Schedule  

NLE Websites -- All DOE Office Websites (Extended Search)

Sector 9 Operations and Schedule Contents: 9-ID User Manual 9-BM User Manual Common Tasks Computers and Software Troubleshooting Web Cameras...

431

Industrial Lighting Techniques and New Developments  

E-Print Network (OSTI)

The energy crisis of the early seventies has had a drastic influence on both the application and development of light sources. This situation has forced us to examine old methods and search for new answers for improved efficiency. We can no longer operate on the premise that more is better. At lower light levels a lighting design is less forgiving. The current thrust in lamp and luminare design has been high efficiency. Tremendous effort has been expended to produce energy efficient sources that deliver better color, improved optical control, and reduced lamp size. Given that we must operate in this arena of heightened energy awareness and that lighting, by its very nature, becomes a prime candidate for reduction, we must not lose sight of the fundamental reason for lighting to provide the ability for us to see details to perform specific tasks. The heart of an industrial plant is the production area. A myriad of tasks must be accomplished. Lighting is installed for humans, not machines. The eye can only adapt to a degree and accommodate a variety of conditions; i.e., color, texture, etc. Higher light levels are required as an individual’s age increases. It has also been confirmed in many studies that light levels directly affect performance. People who have sufficient quantity and quality of illumination can accomplish their work faster and more accurately. A delicate balance lies between energy efficient lighting and under and over-lit spaces. This balance is with the fundamental lighting goal. Any formula to maintain this balance should include two vital factors: First, light output for levels and quality determined by proper task analysis and second, control by design which utilizes the best source and equipment available.

Colotti, M. A.

1985-05-01T23:59:59.000Z

432

High frequency transformerless electronics ballast using double inductor-capacitor resonant power conversion for gas discharge lamps  

SciTech Connect

A novel high frequency LCLC double resonant electronic ballast has been developed for gas discharge lamp applications. The ballast consists of a half-bridge inverter which switches at zero voltage crossing and an LCLC resonant circuit which converts a low ac voltage to a high ac voltage. The LCLC resonant circuit has two LC stages. The first LC stage produces a high voltage before the lamp is ignited. The second LC stage limits lamp current with the circuit inductance after the lamp is ignited. In another embodiment a filament power supply is provided for soft start up and for dimming the lamp. The filament power supply is a secondary of the second resonant inductor. 27 figs.

Lai, J.S.

1995-06-20T23:59:59.000Z

433

Plasma lighting, fiber optics, and daylight collectors: Toward the next revolution in high-efficiency illumination  

SciTech Connect

Combining three recently marketed innovations may provide the next revolution in illumination, making many other recent advances eventually obsolete. The first is plasma lighting, pioneered by Fusion Lighting Inc. of Rockville, Maryland, and first commercially applied by Hutchins International Ltd. of Mississauga, Ontario. This microwave-generated light source yields very high-quality light with efficacies at or beyond high intensity discharge (HID) lamps. The source uses no mercury, thus eliminating lamp disposal problems, and has no cathode, thereby providing very long lamp life. Using no phosphors, it also has very short start and re-strike periods, and is dimmable. The second innovation is in the distribution of light. Commercial developments in fiber optics and light guides now provide products that transfer light from a remote point and distribute it like standard light fixtures. Advances in fiber optic communications and applications to decorative lighting have supplied relatively economical systems for mounting and directing light from both electric light sources and the sun. The third advance is a result of efforts to harness daylight. Unlike architectural daylighting that directs sunlight into perimeter areas through glazing, daylight collectors are roof-mounted devices that supply light to interior and underground spaces through hollow columns and open chases. Aided by improvements and cost reductions in sun-tracking (i.e., heliostatic) controls that capture and concentrate sunlight, such collectors offer a source of free light to locations that might otherwise never receive it. When combined together, these three options could offer a centralized building lighting system that pipes lumens to distribution devices replacing many existing lamps and fixtures.

Audin, L. [Columbia Univ., New York, NY (United States)

1995-06-01T23:59:59.000Z

434

Integrated lighting approach saves energy in post office facilities  

SciTech Connect

The United States Postal Service (USPS) has made numerous efforts to improve the lighting quality and efficiency in their facilities. These efforts have included both traditional retrofits such as the transition to T8 lamps/electronic ballasts and more experimental approaches such as light pipes and sulfur lamps. However, these efforts have focused primarily on their industrial and plant facilities and have had little impact on their small and medium sized facilities, which comprise roughly 90% of their total building stock. These efforts have also neglected the affinity between task and ambient lighting functions.The objective of this project was to develop and demonstrate an integrated lighting system that saves energy while improving the lighting distribution and quality in small and medium sized USPS facilities. Work included the evolution of a novel task lighting fixture designed explicitly to improve the light distribution within the carrier case letter sorting station. The new t ask light system was developed to work in combination with a high efficiency, low-glare ambient lighting system mounted on the ceiling. The use of high-performance task lighting allowed the ambient lighting component to be reduced, thereby limiting the amount of glare produced and reducing the amount of energy consumed.

Mitchell, Jeffrey C.; Siminovitch, Michael J.; Page, Eric R.; Gauna, Kevin W.; Avery, Douglas A.

2000-06-01T23:59:59.000Z

435

15 KJ FLASH LAMP, POWER CONDITIONING UNIT DESIGNED FOR SAFTY, RELIABILITY & MANUFACTURABILITY*  

SciTech Connect

A 15kJoule, Flash Lamp Power Conditioning Unit has been successfully designed, developed, and deployed in the National Ignition Facility (NIF) Preamplifier Modules (PAM). The primary design philosophy of this power conditioning unit (PCU) is safety, reliability, and manufacturability. Cost reduction over commercially equivalent systems was also achieved through an easily manufactured packaging design optimized to meet NIF requirements. While still maintaining low cost, the PCU design includes a robust control system, fault diagnostic system, and safety features. The pulsed power design includes 6 PFN modules, each including a dual series injection trigger transformer, that drive a total of 12 flash lamp loads. The lamps are individually triggered via a 20kV pulse produced by a 1kV, MCT switched capacitive discharge unit on the primary side of the trigger transformer. The remote control interface includes an embedded controller that captures flash lamp current wave forms and fault status for each shot. The embedded controller provides the flexibility of remotely adjusting both the main drive voltage from 1.6 to 2.5 kV and the trigger voltage from 0 to 20 kV.

James, G; Merritt, B; Dreifuerst, G; Strickland, S

2007-08-07T23:59:59.000Z

436

A Local AFOS MOS Program (LAMP) and its Application to Wind Prediction  

Science Conference Proceedings (OSTI)

The Techniques Development Laboratory has a project called the local AFOS MOS Program (LAMP). Its purpose is the development of a system which can produce at any hour of the day in a Weather Service Forecast Office (WSFO) environment Model Output ...

Harry R. Glahn; David A. Unger

1986-07-01T23:59:59.000Z

437

Method and apparatus for powering an electrodeless lamp with reduced radio frequency interference  

DOE Patents (OSTI)

An electrodeless lamp waveguide structure includes tuned absorbers for spurious RF signals. A lamp waveguide with an integral frequency selective attenuation includes resonant absorbers positioned within the waveguide to absorb spurious out-of-band RF energy. The absorbers have a negligible effect on energy at the selected frequency used to excite plasma in the lamp. In a first embodiment, one or more thin slabs of lossy magnetic material are affixed to the sidewalls of the waveguide at approximately one quarter wavelength of the spurious signal from an end wall of the waveguide. The positioning of the lossy material optimizes absorption of power from the spurious signal. In a second embodiment, one or more thin slabs of lossy magnetic material are used in conjunction with band rejection waveguide filter elements. In a third embodiment, one or more microstrip filter elements are tuned to the frequency of the spurious signal and positioned within the waveguide to couple and absorb the spurious signal's energy. All three embodiments absorb negligible energy at the selected frequency and so do not significantly diminish the energy efficiency of the lamp.

Simpson, James E. (Gaithersburg, MD)

1999-01-01T23:59:59.000Z

438

RF driven sulfur lamp having driving electrodes which face each other  

DOE Patents (OSTI)

A high intensity discharge lamp without mercury is disclosed radiating a selected spectrum of which can be almost entirely in the visible range from an envelope that contains a sulfur containing substance. The lamp utilizes a signal source that generates an excitation signal that is externally coupled to the exterior surface of the envelope to excite the enclosed sulfur containing substance. Various embodiments of the lamp use electrodes adjacent the envelope to couple the excitation signal thereto with the face of the electrodes shaped to complement the shape of the exterior surface of the envelope. Two shapes discussed are spherical and cylindrical. To minimize filamentary discharges each envelope may include an elongated stem affixed to the exterior thereof whereby a rotational subsystem spins the envelope. In yet another embodiment the envelope has a Dewar configuration with two electrodes, one positioned near the external curved side surface of the body, and a second to the inner surface of the hole through the envelope. Further, the envelope may contain a backfill of a selected inert gas to assist in the excitation of lamp with that backfill at a pressure of less than 1 atmosphere, wherein the backfill pressure is directly related to the increase or decrease of peak output and inversely related to the increase and decrease of the emitted spectrum from the envelope. The emitting fill can be less than 6 mg/cc, or at least 2 mg/cc of the envelope of a sulfur containing substance. 17 figs.

Gabor, G.; Orr, T.R.; Greene, C.M.; Crawford, D.G.; Berman, S.M.

1999-06-22T23:59:59.000Z

439

Method and apparatus for powering an electrodeless lamp with reduced radio frequency interference  

DOE Patents (OSTI)

An electrodeless lamp waveguide structure includes tuned absorbers for spurious RF signals. A lamp waveguide with an integral frequency selective attenuation includes resonant absorbers positioned within the waveguide to absorb spurious out-of-band RF energy. The absorbers have a negligible effect on energy at the selected frequency used to excite plasma in the lamp. In a first embodiment, one or more thin slabs of lossy magnetic material are affixed to the sidewalls of the waveguide at approximately one quarter wavelength of the spurious signal from an end wall of the waveguide. The positioning of the lossy material optimizes absorption of power from the spurious signal. In a second embodiment, one or more thin slabs of lossy magnetic material are used in conjunction with band rejection waveguide filter elements. In a third embodiment, one or more microstrip filter elements are tuned to the frequency of the spurious signal and positioned within the waveguide to couple and absorb the spurious signal's energy. All three embodiments absorb negligible energy at the selected frequency and so do not significantly diminish the energy efficiency of the lamp. 18 figs.

Simpson, J.E.

1999-06-08T23:59:59.000Z

440

The Fuzzy Design of the Intelligent System for the Energy-Saving Lamps  

Science Conference Proceedings (OSTI)

In the paper, a intelligent system was proposed. It consists of variable converter and intelligent controller. Variable reactor which concludes variable reactance converter and power converter has wide applications in the soft starting, speed controlling ... Keywords: fuzzy control, variable reactor, intelligent control, power converter, Energy-Saving Lamps

Youxin Yuan; Kaihua Cui; Yiping Xiao; Tieliang Xu

2008-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "lamp sector lighting" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Energy Performance and Emissions of Electronic Ballasts Powering 4-Foot Fluorescent Lamps  

Science Conference Proceedings (OSTI)

This power quality (PQ) case study presents tests performed at the Worcester Polytechnic Institute, in contract with the EPRI Power Electronics Applications Center (PEAC) to determine the average efficacy (lumens per watt), displacement power factor, total power factor, and current harmonic distortion of modern electronic ballasts powering fluorescent lamps.

2003-12-31T23:59:59.000Z

442

High frequency electronic ballast for HID lamps. Technical progress report, October 1, 1993--December 31, 1994  

SciTech Connect

Electronic Ballast Systems Corp. has been working on the development of highly efficient (94%) electronic ballast for HID lamps (35W,...,400W) providing energy savings of up to thirty five percent (35%) as compared to the only available alternative, the standard core and coil HID ballasts currently on the market.

1995-03-01T23:59:59.000Z

443

Electronic screw-in ballast and improved circline lamp phase I. Final report  

SciTech Connect

A solid state ballast has been designed for the efficient operation of a 10 in circline fluorescent lamp. The circuit can be manufactured using power hybrid technology. Eight discrete component versions of the ballasts have been delivered to LBL for testing. The results show the solid state fluorescent ballast system is more efficient than the core-coil ballasted systems on the market.

Kohler, T.P.

1980-09-01T23:59:59.000Z

444

Alliant Energy Interstate Power and Light (Gas and Electric)...  

Open Energy Info (EERE)

Water Heaters, Windows, Whole House Fans, Room Air Conditioners, Geothermal Heat Pumps, LED Lighting, Heat Pump Water Heaters Active Incentive Yes Implementing Sector Utility...

445

Alliant Energy Interstate Power and Light (Electric) - Residential...  

Open Energy Info (EERE)

Programmable Thermostats, Refrigerators, Water Heaters, Windows, Geothermal Heat Pumps, LED Lighting, Heat Pump Water Heaters Active Incentive Yes Implementing Sector Utility...

446

BlackLight Power Inc | Open Energy Information  

Open Energy Info (EERE)

search Name BlackLight Power Inc Place Cranbury, New Jersey Zip 8512 Sector Hydro, Hydrogen Product Researching a means of producing energy by catalysing the reaction of...

447

A Comparative Verification of Localized Aviation Model Output Statistics Program (LAMP) and Numerical Weather Prediction (NWP) Model Forecasts of Ceiling Height and Visibility  

Science Conference Proceedings (OSTI)

In an effort to support aviation forecasting, the National Weather Service’s Meteorological Development Laboratory (MDL) has recently redeveloped the Localized Aviation Model Output Statistics (MOS) Program (LAMP) system. LAMP is designed to run ...

David E. Rudack; Judy E. Ghirardelli

2010-08-01T23:59:59.000Z

448

Transportation Sector Model of the National Energy Modeling System. Volume 2 -- Appendices: Part 1  

Science Conference Proceedings (OSTI)

This volume contains input data and parameters used in the model of the transportation sector of the National Energy Modeling System. The list of Transportation Sector Model variables includes parameters for the following: Light duty vehicle modules (fuel economy, regional sales, alternative fuel vehicles); Light duty vehicle stock modules; Light duty vehicle fleet module; Air travel module (demand model and fleet efficiency model); Freight transport module; Miscellaneous energy demand module; and Transportation emissions module. Also included in these appendices are: Light duty vehicle market classes; Maximum light duty vehicle market penetration parameters; Aircraft fleet efficiency model adjustment factors; and List of expected aircraft technology improvements.

NONE

1998-01-01T23:59:59.000Z

449

Correlated two-photon imaging with true thermal light  

E-Print Network (OSTI)

We report the first experimental demonstration of two-photon correlated imaging with true thermal light from a hollow cathode lamp. The coherence time of the source is much shorter than that of previous experiments using random scattered light from a laser. A two-pinhole mask was used as object, and the corresponding thin lens equation was well satisfied. Since thermal light sources are easier to obtain and measure than entangled light it is conceivable that they may be used in special imaging applications.

Da Zhang; Xi-Hao Chen; Yan-Hua Zhai; Ling-An Wu

2005-03-14T23:59:59.000Z

450

New Mexico Brightens Lights to Save Money | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Mexico Brightens Lights to Save Money Mexico Brightens Lights to Save Money New Mexico Brightens Lights to Save Money March 4, 2010 - 12:28pm Addthis Joshua DeLung What are the key facts? In Hobbs, New Mexico, the savings on the city's electric bill could add up to about $20,000 in one year thanks to the retrofitting of 42 intersections as part of a Recovery Act-funded project. By summer, all traffic, warning and pedestrian signals in New Mexico will be replaced with LED lamps, which use significantly less electricity than incandescent lamps. The project is funded by $5 million in Recovery Act money allocated to the State Energy Program, and about 75 percent of the changeovers are already complete. In Hobbs, the savings on the city's electric bill could add up to about $20,000 in one year thanks to the retrofitting of 42

451

Apparatus to facilitate lengthening the life of incandescent lamps  

SciTech Connect

An energizing circuit is described for an incandescent bulb comprising a transformer having a primary winding connectable to an AC mains source and first and second secondary windings for producing first and second voltages. The first secondary winding is connected to an input of a first full-wave rectifier means and the second secondary winding is connected to an input of a second full-wave rectifier means, the full-wave rectifier means having outputs connected in parallel across the bulb. The first voltage is sufficient to fully illuminate the bulb and the second voltage is sufficient to maintain the bulb warm but with little or no light output, a first switch being connected between the first secondary winding and the first rectifier means whereby, when the first switch is open, the bulb is energized solely by the second voltage.

Spissinger, F.H.

1987-03-17T23:59:59.000Z

452

Energy Saving and Good Quality Lighting for Indoor Applications  

E-Print Network (OSTI)

Artificial Lighting in indoor applications is throughout Europe in a lot of cases 20 years or older. That means there are luminaries, lamps and gear in use that are inefficient and so contributing to environmental pollution due to high energy use. These installations one can find in public buildings, offices and industry halls. In offices 75% of the existing installations are old-fashioned and consumes too much energy. A tremendous high potential for energy savings is available. In the past years more and more efficient lighting solutions for these areas where developed. An increase in efficiency but at the same time also in quality of lighting took place. This increase of efficiency can be realized in different ways. In e.g. offices, new fluorescent lamps TL5 with extremely high lamp efficacies, silver-coated aluminum lamellae optics for high luminares efficiency, as well as highly efficient electronic gear take care that the energy consumption is decreasing up to 40%, while the light quality is improving. Latest developments in lighting controls, daylight regulation and presence detection, again reduces the energy bill by another up to 50%.

Lange, H.

2008-01-01T23:59:59.000Z

453

Westinghouse Lighting: Order (2010-CE-09/1001) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Order (2010-CE-09/1001) Order (2010-CE-09/1001) Westinghouse Lighting: Order (2010-CE-09/1001) December 9, 2010 DOE ordered Westinghouse Lighting Corporation to pay a $50,000 civil penalty after finding Westinghouse Lighting had failed to certify that certain models of general service flourescent and incandescent reflector lamps comply with the applicable energy conservation standards. DOE also found that Westinghouse Lighting had manufactured and distributed noncompliant products in commerce in the U.S. The Order adopted a Compromise Agreement, which reflected settlement terms between DOE and Westinghouse Lighting. Westinghouse Lighting: Order (2010-CE-09/1001) More Documents & Publications DuraLamp USA: Order (2010-CE-0912) Lumiram Electric: Order (2010-CE-1014) Philips: Order (2012-SE-2605

454

EXC-12-0006 - In the Matter of Premium Quality Lighting, Inc. | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

6 - In the Matter of Premium Quality Lighting, Inc. 6 - In the Matter of Premium Quality Lighting, Inc. EXC-12-0006 - In the Matter of Premium Quality Lighting, Inc. On July 27, 2012, OHA issued a decision granting an Application for Exception filed by Premium Quality Lighting, Inc. (PQL) for relief from the provisions of 10 C.F.R. Part 430, Energy Conservation Program: Energy Conservation Standards and Test Procedures for General Service Fluorescent Lamps and Incandescent Reflector Lamps (Lighting Efficiency Standards). In its exception request, PQL asserted that it will suffer a serious hardship, gross inequity and an unfair distribution of burdens if required to adhere to the new Lighting Efficiency Standards, effective July 14, 2012 (2009 Final Rule), with respect to its 700 series T8 General Service

455

IFC-Lighting Africa | Open Energy Information  

Open Energy Info (EERE)

IFC-Lighting Africa IFC-Lighting Africa Jump to: navigation, search Logo: IFC-Lighting Africa Name IFC-Lighting Africa Agency/Company /Organization International Finance Corporation (IFC) Sector Energy Focus Area Renewable Energy Topics Co-benefits assessment, - Energy Access Website http://www.lightingafrica.org/ References IFC-Lighting Africa[1] "Lighting Africa, a joint IFC and World Bank program, is helping develop commercial off-grid lighting markets in Sub-Saharan Africa as part of the World Bank Group's wider efforts to improve access to energy. Lighting Africa is mobilizing the private sector to build sustainable markets to provide safe, affordable, and modern off-grid lighting to 2.5 million people in Africa by 2012 and to 250 million people by 2030."

456

Miscellaneous Electricity Services in the Buildings Sector (released in AEO2007)  

Reports and Publications (EIA)

Residential and commercial electricity consumption for miscellaneous services has grown significantly in recent years and currently accounts for more electricity use than any single major end-use service in either sector (including space heating, space cooling, water heating, and lighting). In the residential sector, a proliferation of consumer electronics and information technology equipment has driven much of the growth. In the commercial sector, telecommunications and network equipment and new advances in medical imaging have contributed to recent growth in miscellaneous electricity use

Information Center

2007-03-11T23:59:59.000Z

457

White light emitting diode as liquid crystal display backlight  

E-Print Network (OSTI)

The discovery of high brightness (white) light emitting diode (LED) is considered as a real threat to the current lighting industry in various applications. One of the most promising sectors would be using white LED to ...

Soon, Chian Myau

2007-01-01T23:59:59.000Z

458

LED Lighting  

Energy.gov (U.S. Department of Energy (DOE))

Light-emitting diodes (LEDs) are light sources that differ from more traditional sources of light in that they are semiconductor devices that produce light when an electrical current is applied....

459

Tillamook County PUD - Dairy Lighting Retrofit Rebate Program | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tillamook County PUD - Dairy Lighting Retrofit Rebate Program Tillamook County PUD - Dairy Lighting Retrofit Rebate Program Tillamook County PUD - Dairy Lighting Retrofit Rebate Program < Back Eligibility Agricultural Savings Category Appliances & Electronics Commercial Lighting Lighting Program Info State Oregon Program Type Utility Rebate Program Provider Tillamook County PUD Tillamook PUD offers the Dairy Lighting Retrofit Program for its agricultural members to save energy on lighting in eligible barns/facilities. Tillamook PUD completes a lighting audit of the facility to calculate the energy savings and rebate amount. Incentives are provided for the replacement of existing mercury vapor, incandescent, and T12 fluorescent fixtures with new ORION AG9000 3-lamp T8 fluorescent fixtures. This rebate is available for retrofits only, new construction is not

460

FirstEnergy (Potomac Edison) - Municipal and Street Lighting Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

FirstEnergy (Potomac Edison) - Municipal and Street Lighting FirstEnergy (Potomac Edison) - Municipal and Street Lighting Program (Maryland) FirstEnergy (Potomac Edison) - Municipal and Street Lighting Program (Maryland) < Back Eligibility Commercial Industrial Institutional Local Government Nonprofit Schools State Government Savings Category Appliances & Electronics Commercial Lighting Lighting Program Info State Maryland Program Type Utility Rebate Program Rebate Amount '''Street Lighting'''br/> High Pressure Sodium Fixtures: $10 - $50/unit LED/Induction Fixtures: $50 '''Traffic/Pedestrian Signals''' Lamp/Signal/Arrows: $35/unit Provider FirstEnergy (Potomac Edison) FirstEnergy offers several incentives for non-residential and municipal customers to upgrade traffic signals, pedestrian signals, street lights to more efficient fixtures. The Municipal Lighting Incentive Program offers

Note: This page contains sample records for the topic "lamp sector lighting" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Cornwall Light Power CLP | Open Energy Information  

Open Energy Info (EERE)

England, United Kingdom Zip OX11 9DD Sector Wind energy Product Didcot-based developer of wind farms in the UK. References Cornwall Light & Power (CLP)1 LinkedIn Connections...

462

An Integrated Solid-State LED Luminaire for General Lighting  

Science Conference Proceedings (OSTI)

A strong systems approach to designing and building practical LED-based replacement lamps is lacking. The general method of taking high-performance LEDs and marrying them to standard printed circuit boards, drivers and a heat sink has fallen short of the promise of LED lighting. In this program, a top-down assessment of requirements and a bottom-up reinvention of LED sources, electronics, optics and mechanics have resulted in the highest performance lamp possible. The team, comprised of Color Kinetics, the leaders in LED lighting and Cree, the leaders in LED devices took an approach to reinvent the package, the driver and the overall form and aesthetic of a replacement source. The challenge was to create a new benchmark in LED lighting - the resultant lamp, a PAR38 equivalent, met the light output, color, color quality and efficacy marks set out in the program as well as being dimmable, which is important for market acceptance. The approach combined the use of multiple source die, a chip-on-board approach, a very efficient driver topology, the use of both direct emission and phosphor conversion, and a unique faceted optic to avoid the losses, artifacts and hotspots of lensed approaches. The integral heat sink provided a mechanical base and airflow using a chimney-effect for use in a wide variety of locations and orientations. These research results led to a much better understanding of the system effects of component level technologies. It was clear that best-of-breed sub-system results do not necessarily result in the best end result for the complete system. In doing this work, we did not neglect the practical aspects of these systems. These were not rarified results and commercially impractical but lent themselves to eventual commercial products in the marketplace. The end result - a high performance replacement lamp - will save significant energy while providing a high-quality light source.

Kevin Dowling; Fritz Morgan Ihor Lys; Mike Datta; Bernd Keller; Thomas Yuan

2009-03-31T23:59:59.000Z

463

service sector | OpenEI  

Open Energy Info (EERE)

service sector service sector Dataset Summary Description The energy consumption data consists of five spreadsheets: "overall data tables" plus energy consumption data for each of the following sectors: transport, domestic, industrial and service. Each of the five spreadsheets contains a page of commentary and interpretation. Source UK Department of Energy and Climate Change (DECC) Date Released July 31st, 2010 (4 years ago) Date Updated Unknown Keywords annual energy consumption coal Coke domestic Electricity Electricity Consumption energy data Industrial Natural Gas Petroleum service sector transportation UK Data application/zip icon Five Excel spreadsheets with UK Energy Consumption data (zip, 2.6 MiB) Quality Metrics Level of Review Peer Reviewed Comment The data in ECUK are classified as National Statistics

464

industrial sector | OpenEI  

Open Energy Info (EERE)

industrial sector industrial sector Dataset Summary Description Biomass energy consumption and electricity net generation in the industrial sector by industry and energy source in 2008. This data is published and compiled by the U.S. Energy Information Administration (EIA). Source EIA Date Released August 01st, 2010 (4 years ago) Date Updated August 01st, 2010 (4 years ago) Keywords 2008 biomass consumption industrial sector Data application/vnd.ms-excel icon industrial_biomass_energy_consumption_and_electricity_2008.xls (xls, 27.6 KiB) Quality Metrics Level of Review Peer Reviewed Comment Temporal and Spatial Coverage Frequency Annually Time Period 2008 License License Open Data Commons Public Domain Dedication and Licence (PDDL) Comment Rate this dataset Usefulness of the metadata

465

Treatability study for removal of leachable mercury in crushed fluorescent lamps  

SciTech Connect

Nonserviceable fluorescent lamps removed from radiological control areas at the Oak Ridge Department of Energy facilities have been crushed and are currently managed as mixed waste (hazardous and radiologically contaminated). We present proposed treatment flowsheets and supporting treatability study data for conditioning this solid waste residue so that it can qualify for disposal in a sanitary landfill. Mercury in spent fluorescent lamps occurs primarily as condensate on high-surface-area phosphor material. It can be solubilized with excess oxidants (e.g., hypochlorite solution) and stabilized by complexation with halide ions. Soluble mercury in dechlorinated saline solution is effectively removed by cementation with zero-valent iron in the form of steel wool. In packed column dynamic flow testing, soluble mercury was reduced to mercury metal and insoluble calomel, loading > 1.2 g of mercury per grain of steel wool before an appreciable breakthrough of soluble mercury in the effluent.

Bostick, W.D.; Beck, D.E.; Bowser, K.T. [and others

1996-02-01T23:59:59.000Z

466

Flathead Electric Cooperative - Commercial Lighting Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

You are here You are here Home » Flathead Electric Cooperative - Commercial Lighting Rebate Program Flathead Electric Cooperative - Commercial Lighting Rebate Program < Back Eligibility Agricultural Commercial Industrial Savings Category Appliances & Electronics Commercial Lighting Lighting Heating & Cooling Commercial Heating & Cooling Maximum Rebate 70% of project cost Program Info State Montana Program Type Utility Rebate Program Rebate Amount Retrofit Lighting: $3 - $400 per unit New Construction Lighting: $10 - $50 per unit Provider Flathead Electric Cooperative Flathead Electric Cooperative, in conjunction with Bonneville Power Administration, encourages energy efficiency in the commercial sector by providing a commercial lighting retro-fit rebate program and a new

467

EXC-12-0001, EXC-12-0002, EXC-12-0003 - In the Matter of Philips Lighting  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1, EXC-12-0002, EXC-12-0003 - In the Matter of Philips 1, EXC-12-0002, EXC-12-0003 - In the Matter of Philips Lighting Company, GE Lighting, and OSRAM SYLVANIA, Inc. EXC-12-0001, EXC-12-0002, EXC-12-0003 - In the Matter of Philips Lighting Company, GE Lighting, and OSRAM SYLVANIA, Inc. On April 16, 2012, OHA issued a decision granting Applications for Exception filed respectively by Philips Lighting Company (Philips), GE Lighting (GE) and OSRAM SYLVANIA, Inc. (OSI) (collectively, "the Applicants"), for relief from the provisions of 10 C.F.R. Part 430, Energy Conservation Program: Energy Conservation Standards and Test Procedures for General Service Fluorescent Lamps and Incandescent Reflector Lamps (Lighting Efficiency Standards). In their exception requests, the Applicants asserted that they will suffer a serious hardship, gross

468

EXC-12-0001, EXC-12-0002, EXC-12-0003 - In the Matter of Philips Lighting  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

EXC-12-0001, EXC-12-0002, EXC-12-0003 - In the Matter of Philips EXC-12-0001, EXC-12-0002, EXC-12-0003 - In the Matter of Philips Lighting Company, GE Lighting, and OSRAM SYLVANIA, Inc. EXC-12-0001, EXC-12-0002, EXC-12-0003 - In the Matter of Philips Lighting Company, GE Lighting, and OSRAM SYLVANIA, Inc. On April 16, 2012, OHA issued a decision granting Applications for Exception filed respectively by Philips Lighting Company (Philips), GE Lighting (GE) and OSRAM SYLVANIA, Inc. (OSI) (collectively, "the Applicants"), for relief from the provisions of 10 C.F.R. Part 430, Energy Conservation Program: Energy Conservation Standards and Test Procedures for General Service Fluorescent Lamps and Incandescent Reflector Lamps (Lighting Efficiency Standards). In their exception requests, the Applicants asserted that they will suffer a serious hardship, gross

469

Determination of mercury distribution inside spent compact fluorescent lamps by atomic absorption spectrometry  

Science Conference Proceedings (OSTI)

Highlights: Black-Right-Pointing-Pointer New treatments for CFL are required considering the aim of Directive 202/96/CE. Black-Right-Pointing-Pointer It is shown that most of the mercury introduced into a CFL is in the phosphor powder. Black-Right-Pointing-Pointer Experimental conditions for microwave-assisted sample digestion followed by AAS measurements are described. Black-Right-Pointing-Pointer By washing the glass it is possible to reduce the concentration below legal limits. - Abstract: In this study, spent compact fluorescent lamps were characterized to determine the distribution of mercury. The procedure used in this research allowed mercury to be extracted in the vapor phase, from the phosphor powder, and the glass matrix. Mercury concentration in the three phases was determined by the method known as cold vapor atomic absorption spectrometry. Median values obtained in the study showed that a compact fluorescent lamp contained 24.52 {+-} 0.4 ppb of mercury in the vapor phase, 204.16 {+-} 8.9 ppb of mercury in the phosphor powder, and 18.74 {+-} 0.5 ppb of mercury in the glass matrix. There are differences in mercury concentration between the lamps since the year of manufacture or the hours of operation affect both mercury content and its distribution. The 85.76% of the mercury introduced into a compact fluorescent lamp becomes a component of the phosphor powder, while more than 13.66% is diffused through the glass matrix. By washing and eliminating all phosphor powder attached to the glass surface it is possible to classified the glass as a non-hazardous waste.

Rey-Raap, Natalia [Departamento de Ingenieria Mecanica y Construccion, Universitat Jaume I de Castellon, Av. de Vicent Sos Baynat s/n, 12071 Castellon de la Plana, Espana (Spain); Gallardo, Antonio, E-mail: gallardo@emc.uji.es [Departamento de Ingenieria Mecanica y Construccion, Universitat Jaume I de Castellon, Av. de Vicent Sos Baynat s/n, 12071 Castellon de la Plana, Espana (Spain)

2012-05-15T23:59:59.000Z

470

Energy Sector Jobs | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Sector Jobs Energy Sector Jobs New Report Highlights Growth of America's Clean Energy Job Sector: Taking a moment to break-down key findings from the latest Clean Energy Jobs...

471

Integrated-circuit control for two-lamp electronic ballast. Final report  

SciTech Connect

Circuitry is described for a solid-state, high-frequency fluorescent ballast designed to operate two F40 T-12 rapid-start lamps. The circuits are designed to be produced by hybrid integrated circuit (IC) technology. The signal components are produced on a single IC chip; the power transistors are attached to an alumina substrate. The initial IC version reduces the component count by about 50%. The cost of each IC in 500K lots is $0.70, replacing discrete parts costing $2.25. Additional savings of more than $1.00 per unit are realized by the decreased assembly time and improved reliability of the ICs. The system performance (two-lamp F40) was compared to the discrete version of the ballast and to an efficient core-coil ballast and found to be 6% less and 20% more efficient, respectively. The decrease in efficiency relative to the discrete version of the ballast is due to retaining some power to the filaments during operation in order to maintain normal lamp life.

Kohler, T.P.

1982-11-01T23:59:59.000Z

472

Updated Buildings Sector Appliance and Equipment Costs and Efficiency  

U.S. Energy Information Administration (EIA) Indexed Site

Full report (4.1 mb) Full report (4.1 mb) Heating, cooling, & water heating equipment Appendix A - Technology Forecast Updates - Residential and Commercial Building Technologies - Reference Case (1.9 mb) Appendix B - Technology Forecast Updates - Residential and Commercial Building Technologies - Advanced Case (1.3 mb) Lighting and commercial ventilation & refrigeration equipment Appendix C - Technology Forecast Updates - Residential and Commercial Building Technologies - Reference Case (1.1 mb) Appendix D - Technology Forecast Updates - Residential and Commercial Building Technologies - Advanced Case (1.1 mb) Updated Buildings Sector Appliance and Equipment Costs and Efficiency Release date: August 7, 2013 Energy used in the residential and commercial sectors provides a wide range

473

Preliminary Results on Luminaire Designs for Hybrid Solar Lighting Systems  

DOE Green Energy (OSTI)

We report on the design of two hybrid lighting luminaires that blend light from a fiber optic end-emitted solar source with electric T8 fluorescent lamps. Both designs involve the retrofit of a commercially-available recessed fluorescent luminaire with minimal reductions in the original luminaire's optical efficiency. Two methods for high-angle dispersion of fiber optic end-emitted solar light are described and the resulting spatial intensity distributions, simulated using ZEMAX, are compared with standard cylindrical fluorescent tubes. Differences in spatial intensity distribution are qualitatively characterized and potential design improvements discussed.

Earl, D.D.

2001-06-15T23:59:59.000Z

474

Demonstration Assessment of Light Emitting Diode (LED) Commercial Garage Lights In the Providence Portland Medical Center, Portland, Oregon  

SciTech Connect

This U.S. Department of Energy GATEWAY Demonstration project studied the applicability of light-emitting diode (LED) luminaires for commercial parking garage applications. High-pressure sodium (HPS) area luminaires were replaced with new LED area luminaires. The project was supported under the U.S. Department of Energy (DOE) Solid State Lighting Program. Other participants in the demonstration project included Providence Portland Medical Center in Portland, Oregon, the Energy Trust of Oregon, and Lighting Sciences Group (LSG) Inc. Pacific Northwest National Laboratory (PNNL) conducted the measurements and analysis of the results. PNNL manages GATEWAY demonstrations for DOE and represents their perspective in the conduct of the work. Quantitative and qualitative measurements of light and electrical power were taken at the site for both HPS and LED light sources. Economic costs were estimated and garage users’ responses to the new light sources were gauged with a survey. Six LED luminaires were installed in the below-ground parking level A, replacing six existing 150W HPS lamps spread out over two rows of parking spaces. Illuminance measurements were taken at floor level approximately every 4 ft on a 60-ft x 40-ft grid to measure light output of these LED luminaires which were termed the “Version 1” luminaires. PNNL conducted power measurements of the circuit in the garage to which the 6 luminaires were connected and determined that they drew an average of 82 W per lamp. An improved LED luminaire, Version 2, was installed in Level B of the parking garage. Illuminance measurements were not made of this second luminaire on site due to higher traffic conditions, but photometric measurements of this lamp and Version 1 were made in an independent testing laboratory and power usage for Version 2 was also measured. Version 1 was found to produce 3600 lumens and Version 2 was found to produce 4700 lumens of light and to consume 78 Watts. Maximum and minimum light levels were measured for the HPS and LED Version 1 luminaires and projected for the Version 2 luminaires. Maximum light levels were 23.51 foot candles, 20.54 fc, and 26.7 fc respectively and minimum light levels were 1.49 fc, 1.45 fc, and 1.88 fc. These results indicate very similar or even slightly higher light levels produced by the LED lamps, despite the higher lumen output of the HPS lamp. The LED lamps provide higher luminaire efficacy because all of the light is directed down and out. None of it is “lost” in the fixture. Also the HPS luminaire had poorly designed optics and a plastic covering that tended to get dirty and cracked, further decreasing the realized light output.[is this an accurate way to say this?] Consumer perceptions of the Version 2 LED were collected via a written survey form given to maintenance and security personnel. More than half felt the LED luminaires provided more light than the HPS lamps and a majority expressed a preference for the new lamps when viewing the relamped area through a security camera. Respondents commented that the LED luminaires were less glary, created less shadows, had a positive impact on visibility, and improved the overall appearance of the area. PNNL conducted an economic analysis and found that the Version 1 lamp produced annual energy savings of 955 kWh and energy cost savings of $76.39 per lamp at electricity rates of 6.5 cents per kWh and $105.03 at 11 cents per kWh. PNNL found that the Version 2 lamp produced annual energy savings of 991 kWh and energy cost savings of $79.26 per lamp at electricity rates of 6.5 cents per kWh and $108.98 at 11 cents per kWh. PNNL also calculated simple payback and found that Version 1 showed paybacks of 5.4 yrs at 6.5c/kWh and 4.1 yrs at 11c/kWh while Version 2 showed paybacks of 5.2 yrs at 6.5c/kWh and 3.9 yrs at 11c/kWh.

Ton, My K.; Richman, Eric E.; Gilbride, Theresa L.

2008-11-11T23:59:59.000Z

475

Attribution of climate forcing to economic sectors  

NLE Websites -- All DOE Office Websites (Extended Search)

Attribution of climate forcing to economic sectors Title Attribution of climate forcing to economic sectors Publication Type Journal Article Year of Publication 2010 Authors Unger,...

476

Energy Efficiency Report: Chapter 3: Residential Sector  

U.S. Energy Information Administration (EIA)

3. The Residential Sector Introduction. More than 90 million single-family, multifamily, and mobile home households encompass the residential sector.

477

U.S. Propane Demand Sectors (1996)  

U.S. Energy Information Administration (EIA)

The residential and commercial sector and the chemical sector are the largest end users of propane in the U.S., accounting for 34% and 41% ...

478

Building Energy Retrofit Research: Multifamily Sector  

NLE Websites -- All DOE Office Websites (Extended Search)

Building Energy Retrofit Research: Multifamily Sector Title Building Energy Retrofit Research: Multifamily Sector Publication Type Report Year of Publication 1985 Authors Diamond,...

479

Westinghouse Lighting: Noncompliance Determination (2010-CE-09/1001) |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Noncompliance Determination Noncompliance Determination (2010-CE-09/1001) Westinghouse Lighting: Noncompliance Determination (2010-CE-09/1001) October 8, 2010 DOE issued a Notice of Noncompliance Determination to Westinghouse Lighting Corporation finding that model F40T12/CWE (Westinghouse product code 07521000), a general service fluorescent lamp, and model 15GLOBE/65/2 (Westinghouse product code 3800400), a medium base compact fluorescent lamp, do not comport with the energy conservation standards. DOE determined the products were noncompliant based on the company's own testing. Westinghouse must immediately notify each person (or company) to whom Westinghouse distributed the noncompliant products that the products do not meet Federal standards. In addition, Westinghouse must provide to

480

Performance of electronic ballasts and other new lighting equipment  

SciTech Connect

This study discusses parameters for selecting the most suitable auxiliary lighting device to operate and control gas-discharge lamps. The devices tested in this study include solid-state, fluorescent, and high-intensity discharge (HID) ballasts; current limiters; and dynamic lighting controls. They have been evaluated when operating the standard, 40-W, F-40, T-12, rapid-start, cool-white fluorescent lamps. Solid-state ballast performance varied widely, from 68 to 79 lumens per watt (1m/W) in efficacy, and from 0.83 to 0.98 in ballast factor. System efficacy was measured at up to 26% higher than standard core-coil ballast efficacy.

Verderber, R.R.; Morse, O.

1985-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "lamp sector lighting" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.