Sample records for lamp fixtures applicable

  1. New Energy Efficiency Standards for Metal Halide Lamp Fixtures...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Metal Halide Lamp Fixtures to Save on Energy Bills and Reduce Carbon Pollution New Energy Efficiency Standards for Metal Halide Lamp Fixtures to Save on Energy Bills and Reduce...

  2. Heat transfer assembly for a fluorescent lamp and fixture

    DOE Patents [OSTI]

    Siminovitch, M.J.; Rubenstein, F.M.; Whitman, R.E.

    1992-12-29T23:59:59.000Z

    In a lighting fixture including a lamp and a housing, a heat transfer structure is disclosed for reducing the minimum lamp wall temperature of a fluorescent light bulb. The heat transfer structure, constructed of thermally conductive material, extends from inside the housing to outside the housing, transferring heat energy generated from a fluorescent light bulb to outside the housing where the heat energy is dissipated to the ambient air outside the housing. Also disclosed is a method for reducing minimum lamp wall temperatures. Further disclosed is an improved lighting fixture including a lamp, a housing and the aforementioned heat transfer structure. 11 figs.

  3. Heat transfer assembly for a fluorescent lamp and fixture

    SciTech Connect (OSTI)

    Siminovitch, Michael J. (Richmond, CA); Rubenstein, Francis M. (Berkeley, CA); Whitman, Richard E. (Richmond, CA)

    1992-01-01T23:59:59.000Z

    In a lighting fixture including a lamp and a housing, a heat transfer structure is disclosed for reducing the minimum lamp wall temperature of a fluorescent light bulb. The heat transfer structure, constructed of thermally conductive material, extends from inside the housing to outside the housing, transferring heat energy generated from a fluorescent light bulb to outside the housing where the heat energy is dissipated to the ambient air outside the housing. Also disclosed is a method for reducing minimum lamp wall temperatures. Further disclosed is an improved lighting fixture including a lamp, a housing and the aforementioned heat transfer structure.

  4. Thermal element for maintaining minimum lamp wall temperature in fluorescent fixtures

    DOE Patents [OSTI]

    Siminovitch, M.J.

    1992-11-10T23:59:59.000Z

    In a lighting fixture including a lamp and a housing, an improvement is disclosed for maintaining a lamp envelope area at a cooler, reduced temperature relative to the enclosed housing ambient. The improvement comprises a thermal element in thermal communication with the housing extending to and springably urging thermal communication with a predetermined area of the lamp envelope surface. 12 figs.

  5. Thermal element for maintaining minimum lamp wall temperature in fluorescent fixtures

    DOE Patents [OSTI]

    Siminovitch, Michael J. (Richmond, CA)

    1992-01-01T23:59:59.000Z

    In a lighting fixture including a lamp and a housing, an improvement is disclosed for maintaining a lamp envelope area at a cooler, reduced temperature relative to the enclosed housing ambient. The improvement comprises a thermal element in thermal communication with the housing extending to and springably urging thermal communication with a predetermined area of the lamp envelope surface.

  6. Application Summary Report 22: LED MR16 Lamps

    SciTech Connect (OSTI)

    Royer, Michael P.

    2014-07-23T23:59:59.000Z

    This report analyzes the independently tested photometric performance of 27 LED MR16 lamps. It describes initial performance based on light output, efficacy, distribution, color quality, electrical characteristics, and form factor, with comparisons to a selection of benchmark halogen MR16s and ENERGY STAR qualification thresholds. Three types of products were targeted. First, CALiPER sought 3000 K lamps with the highest rated lumen output (i.e., at least 500 lm) or a claim of equivalency to a 50 W halogen MR16 or higher. The test results indicate that while the initial performance of LED MR16s has improved across the board, market-available products still do not produce the lumen output and center beam intensity of typical 50 W halogen MR16 lamps. In fact, most of the 18 lamps in this category had lower lumen output and center beam intensity than a typical 35 W halogen MR16 lamp. Second, CALiPER sought lamps with a CRI of 90 or greater. Only four manufacturers were identified with a product in this category. CALiPER testing confirmed the performance of these lamps, which are a good option for applications where high color fidelity is needed. A vast majority of the LED MR16 lamps have a CRI in the low 80s; this is generally acceptable for ambient lighting, but may not always be acceptable for focal lighting. For typical LED packages, there is a fundamental tradeoff between CRI and efficacy, but the lamps in the high-CRI group in this report still offer comparable performance to the rest of the Series 22 products in other performance areas. Finally, CALiPER sought lamps with a narrow distribution, denoted as a beam angle less than 15°. Five such lamps were purchased. Notably, no lamp was identified as having high lumen output (500 lumens or greater), high CRI (90 or greater), a narrow distribution (15° or less), and an efficacy greater than 60 lm/W. This would be an important achievement for LED MR16s especially if output could reach approximately 700 800 lumens, or the approximate equivalent of a 50 W halogen MR16 lamp. Many factors beyond photometric performance should be considered during specification. For example, performance over time, transformer and dimmer compatibility, and total system performance are all critical to a successful installation. Subsequent CALiPER reports will investigate more complex issues.

  7. Performance of T12 and T8 Fluorescent Lamps and Troffers and LED Linear Replacement Lamps CALiPER Benchmark Report

    SciTech Connect (OSTI)

    Myer, Michael; Paget, Maria L.; Lingard, Robert D.

    2009-01-16T23:59:59.000Z

    The Department of Energy (DOE) Commercially Available LED Product Evaluation and Reporting (CALiPER) Program was established in 2006 to investigate the performance of light-emitting diode (LED) based luminaires and replacement lamps. To help users better compare LED products with conventional lighting technologies, CALiPER has also performed benchmark research and testing of traditional (i.e., non-LED) lamps and fixtures. This benchmark report addresses standard 4-foot fluorescent lamps (i.e., T12 and T8) and the 2-foot by 4-foot recessed troffers in which they are commonly used. This report also examines available LED replacements for T12 and T8 fluorescent lamps, and their application in fluorescent troffers. The construction and operation of linear fluorescent lamps and troffers are discussed, as well as fluorescent lamp and fixture performance, based on manufacturer data and CALiPER benchmark testing. In addition, the report describes LED replacements for linear fluorescent lamps, and compares their bare lamp and in situ performance with fluorescent benchmarks on a range of standard lighting measures, including power usage, light output and distribution, efficacy, correlated color temperature, and the color rendering index. Potential performance and application issues indicated by CALiPER testing results are also examined.

  8. Dual LED/incandescent security fixture

    DOE Patents [OSTI]

    Gauna, Kevin Wayne

    2005-06-21T23:59:59.000Z

    A dual LED and incandescent security lighting system uses a hybrid approach to LED illumination. It combines an ambient LED illuminator with a standard incandescent lamp on a motion control sensor. The LED illuminator will activate with the onset of darkness (daylight control) and typically remain on during the course of the night ("always on"). The LED illumination, typically amber, is sufficient to provide low to moderate level lighting coverage to the wall and ground area adjacent to and under the fixture. The incandescent lamp is integrated with a motion control circuit and sensor. When movement in the field of view is detected (after darkness), the incandescent lamp is switched on, providing an increased level of illumination to the area. Instead of an "always on" LED illuminator, the LEDs may also be switched off when the incandescent lamp is switched on.

  9. Application of vane-type resonator to microwave powered electrodeless HID lamp

    SciTech Connect (OSTI)

    Hochi, Akira; Takeda, Mamoru

    1999-07-01T23:59:59.000Z

    A cavity resonator has been generally used as microwave applicator for an electrodeless high intensity discharge (HID) lamp. The size of a cavity resonator is determined by the wavelength of a microwave applied. For example, for a microwave of 2.45 GHz, an inner diameter of more than about 76 mm is necessary for obtaining a microwave resonant field, and then the size of a plasma arc capable of maintaining a stable discharge is experimentally limited at about 15 mm and above. Accordingly the microwave powered electrodeless HID lamp device using cavity resonator is inappropriate in applications where a point light source is required. A vane-type resonator is generally known as an anode of a magnetron, which decides the oscillation frequency of the magnetron. The authors used 3-D finite element method simulation for a design of a vane-type resonator with parabolic reflector to obtain a desired resonant frequency. According to the results of the simulation, the sizes of a 4-vanes resonator with the parabolic reflector were decided, and the resonator made of aluminum and copper was prepared. An electrodeless lamp with InBr and Ar gas enclosed in a spherical quartz glass tube having an inner diameter of about 4 mm was also prepared, and was set at center portion of the resonator. The total luminous flux was about 2,150 lm at microwave input of 27 W. Incidentally, the CRI and Tc for this lamp were 93 and 10,200 K, respectively. Thus, it becomes possible to efficiently couple microwave energy with a smaller-sized electrodeless HID lamp than conventional.

  10. New Lighting Fixtures: Combining Creativity and Style with Energy Efficiency

    SciTech Connect (OSTI)

    Gordon, Kelly L.; Foster, Rebecca; McGowan, Terry

    2004-10-01T23:59:59.000Z

    This article for a building trade magazine describes a national design competition for energy efficient lighting sponsored by the U.S. Department of Energy, the American Lighting Association, and the Consortium for Energy Efficiency, with winners announced at ALA's Annual Conference May 14, 2004, in Tucson. The Lighting for Tomorrow competition was the first national lighting fixture design competition focusing on energy-efficient residential lighting. The competition invited fixture manufacturers and designers to come up with beautiful, functional lighting fixtures that also happen to be energy efficient. Fixtures were required to use a ''dedicated'' energy-efficient light source, such as a pin-based fluorescent lamp that cannot be replaced with a screw-in incandescent bulb. Fixtures also had to meet a minimum energy efficiency level that eliminated use of incandescent and halogen lamps, leaving the door open only to fluorescent sources and LEDs. More than 150 paper designs were submitted in the first phase of the competition, in 2003. Of those, 24 finalists were invited to submit working prototypes in 2004, and the winners were announced in May. The Grand Prize of $10,000 went to American Fluorescent of Waukegan, Illinois, for its ''Salem'' chandelier. Some winning fixtures are already available through Lowe's Home Improvement Centers.

  11. Integral CFLs performance in table lamps

    SciTech Connect (OSTI)

    Page, E.; Driscoll, D.; Siminovitch, M.

    1997-03-01T23:59:59.000Z

    This paper focuses on performance variations associated with lamp geometry and distribution in portable table luminaires. If correctly retrofit with compact fluorescent lamps (CFLs), these high use fixtures produce significant energy savings, but if misused, these products could instead generate consumer dissatisfaction with CFLs. It is the authors assertion that the lumen distribution of the light source within the luminaires plays a critical role in total light output, fixture efficiency and efficacy, and, perhaps most importantly, perceived brightness. The authors studied nearly 30 different integral (screw-based) CFLs available on the market today in search of a lamp, or group of lamps, which work best in portable table luminaires. The findings conclusively indicate that horizontally oriented CFLs outperform all other types of CFLs in nearly every aspect.

  12. Multiple direction vibration fixture

    DOE Patents [OSTI]

    Cericola, Fred (Albuquerque, NM); Doggett, James W. (Albuquerque, NM); Ernest, Terry L. (Albuquerque, NM); Priddy, Tommy G. (Rockville, MD)

    1991-01-01T23:59:59.000Z

    An apparatus for simulating a rocket launch environment on a test item undergoing centrifuge testing by subjecting the item simultaneously or separately to vibration along an axis of centripetal force and along an axis perpendicular to the centripetal force axis. The apparatus includes a shaker motor supported by centrifuge arms and a right angle fixture pivotally connected to one of the shaker motor mounts. When the shaker motor vibrates along the centripetal force axis, the vibrations are imparted to a first side of the right angle fixture. The vibrations are transmitted 90 degrees around the pivot and are directed to a second side of the right angle fixture which imparts vibrations perpendicular to the centripetal force axis. The test item is in contact with a third side of the right angle fixture and receives both centripetal-force-axis vibrations and perpendicular axis vibrations simultaneously. A test item can be attached to the third side near the flexible coupling or near the air bag to obtain vibrations along the centripetal force axis or transverse to the centripetal force axis.

  13. DuraLamp USA: Order (2010-CE-0912)

    Broader source: Energy.gov [DOE]

    DOE ordered DuraLamp USA, Inc. to pay a $2,500 civil penalty after finding DuraLamp USA had failed to certify that model PAR 30, an incandescent reflector lamp, complies with the applicable energy conservation standards.

  14. Controlled shear/tension fixture

    DOE Patents [OSTI]

    Hsueh, Chun-Hway (Knoxville, TN); Liu, Chain-tsuan (Knoxville, TN); George, Easo P. (Knoxville, TN)

    2012-07-24T23:59:59.000Z

    A test fixture for simultaneously testing two material test samples is provided. The fixture provides substantially equal shear and tensile stresses in each test specimens. By gradually applying a load force to the fixture only one of the two specimens fractures. Upon fracture of the one specimen, the fixture and the load train lose contact and the second specimen is preserved in a state of upset just prior to fracture. Particular advantages of the fixture are (1) to control the tensile to shear load on the specimen for understanding the effect of these stresses on the deformation behavior of advanced materials, (2) to control the location of fracture for accessing localized material properties including the variation of the mechanical properties and residual stresses across the thickness of advanced materials, (3) to yield a fractured specimen for strength measurement and an unfractured specimen for examining the microstructure just prior to fracture.

  15. Metal Halide Lamp Ballasts and Fixtures | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't YourTransport(FactDepartment3311, 3312), OctoberMay 18-19,DepartmentEnergyMetal

  16. Method for removal of phosgene from boron trichloride. [DOE patent application; mercury arc lamp

    DOE Patents [OSTI]

    Freund, S.M.

    1981-09-03T23:59:59.000Z

    Selective ultraviolet photolysis using an unfiltered mercury arc lamp has been used to substantially reduce the phosgene impurity in a mixture of boron trichloride and phosgene. Infrared spectrophotometric analysis of the sample before and after irradiation shows that it is possible to highly purify commercially available boron trichloride with this method.

  17. Simulation of pyroshock environments using a tunable resonant fixture

    DOE Patents [OSTI]

    Davie, N.T.

    1996-10-15T23:59:59.000Z

    Disclosed are a method and apparatus for simulating pyrotechnic shock for the purpose of qualifying electronic components for use in weapons, satellite, and aerospace applications. According to the invention, a single resonant bar fixture has an adjustable resonant frequency in order to exhibit a desired shock response spectrum upon mechanical impact. The invention eliminates the need for availability of a large number of different fixtures, capable of exhibiting a range of shock response characteristics, in favor of a single tunable system. 32 figs.

  18. Simulation of pyroshock environments using a tunable resonant fixture

    DOE Patents [OSTI]

    Davie, Neil T. (Cedar Crest, NM)

    1996-01-01T23:59:59.000Z

    Disclosed are a method and apparatus for simulating pyrotechnic shock for the purpose of qualifying electronic components for use in weapons, satellite, and aerospace applications. According to the invention, a single resonant bar fixture has an adjustable resonant frequency in order to exhibit a desired shock response spectrum upon mechanical impact. The invention eliminates the need for availability of a large number of different fixtures, capable of exhibiting a range of shock response characteristics, in favor of a single tunable system.

  19. Aperture lamp

    DOE Patents [OSTI]

    MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD)

    2003-01-01T23:59:59.000Z

    A discharge lamp includes means for containing a light emitting fill, the fill being capable of absorbing light at one wavelength and re-emitting the light at a different wavelength, the light emitted from the fill having a first spectral power distribution in the absence of reflection of light back into the fill; means for exciting the fill to cause the fill to emit light; and means for reflecting some of the light emitted by the fill back into the fill while allowing some light to exit, the exiting light having a second spectral power distribution with proportionately more light in the visible region as compared to the first spectral power distribution, wherein the light re-emitted by the fill is shifted in wavelength with respect to the absorbed light and the magnitude of the shift is in relation to an effective optical path length. Another discharge lamp includes an envelope; a fill which emits light when excited disposed in the envelope; a source of excitation power coupled to the fill to excite the fill and cause the fill to emit light; and a reflective ceramic structure disposed around the envelope and defining an light emitting opening, wherein the structure comprises a sintered body built up directly on the envelope and made from a combination of alumina and silica.

  20. LED lamp

    DOE Patents [OSTI]

    Galvez, Miguel; Grossman, Kenneth; Betts, David

    2013-11-12T23:59:59.000Z

    There is herein described a lamp for providing white light comprising a plurality of light sources positioned on a substrate. Each of said light sources comprises a blue light emitting diode (LED) and a dome that substantially covers said LED. A first portion of said blue light from said LEDs is transmitted through said domes and a second portion of said blue light is converted into a red light by a first phosphor contained in said domes. A cover is disposed over all of said light sources that transmits at least a portion of said red and blue light emitted by said light sources. The cover contains a second phosphor that emits a yellow light in response to said blue light. The red, blue and yellow light combining to form the white light and the white light having a color rendering index (CRI) of at least about 80.

  1. DuraLamp USA: Proposed Penalty (2010-CE-0912)

    Broader source: Energy.gov [DOE]

    DOE alleged in a Notice of Proposed Civil Penalty that DuraLamp USA, Inc. failed to certify a variety of general service fluorescent lamps as compliant with the applicable energy conservation standards.

  2. Max Tech and Beyond: Fluorescent Lamps

    SciTech Connect (OSTI)

    Scholand, Michael

    2012-04-01T23:59:59.000Z

    Fluorescent lamps are the most widely used artificial light source today, responsible for approximately 70% of the lumens delivered to our living spaces globally. The technology was originally commercialized in the 1930's, and manufacturers have been steadily improving the efficacy of these lamps over the years through modifications to the phosphors, cathodes, fill-gas, operating frequency, tube diameter and other design attributes. The most efficient commercially available fluorescent lamp is the 25 Watt T5 lamp. This lamp operates at 114-116 lumens per watt while also providing good color rendering and more than 20,000 hours of operating life. Industry experts interviewed indicated that while this lamp is the most efficient in the market today, there is still a further 10 to 14% of potential improvements that may be introduced to the market over the next 2 to 5 years. These improvements include further developments in phosphors, fill-gas, cathode coatings and ultraviolet (UV) reflective glass coatings. The commercialization of these technology improvements will combine to bring about efficacy improvements that will push the technology up to a maximum 125 to 130 lumens per watt. One critical issue raised by researchers that may present a barrier to the realization of these improvements is the fact that technology investment in fluorescent lamps is being reduced in order to prioritize research into light emitting diodes (LEDs) and ceramic metal halide high intensity discharge (HID) lamps. Thus, it is uncertain whether these potential efficacy improvements will be developed, patented and commercialized. The emphasis for premium efficacy will continue to focus on T5 lamps, which are expected to continue to be marketed along with the T8 lamp. Industry experts highlighted the fact that an advantage of the T5 lamp is the fact that it is 40% smaller and yet provides an equivalent lumen output to that of a T8 or T12 lamp. Due to its smaller form factor, the T5 lamp contains less material (i.e., glass, fill gas and phosphor), and has a higher luminance, enabling fixtures to take advantage of the smaller lamp size to improve the optics and provide more efficient overall system illuminance. In addition to offering the market a high-quality efficacious light source, another strong value proposition of fluorescent lighting is its long operating life. In today's market, one manufacturer is offering fluorescent lamps that have a rated life of 79,000 hours - which represents 18 years of service at 12 hours per day, 365 days per year. These lamps, operated using a long-life ballast specified by the manufacturer, take advantage of improvements in cathode coatings, fill gas chemistry and pressure to extend service life by a factor of four over conventional fluorescent lamps. It should be noted that this service life is also longer (approximately twice as long) as today's high-quality LED products. The fluorescent market is currently focused on the T5 and T8 lamp diameters, and it is not expected that other diameters would be introduced. Although T8 is a more optimal diameter from an efficacy perspective, the premium efficiency and optimization effort has been focused on T5 lamps because they are 40% smaller than T8, and are designed to operate at a higher temperature using high-frequency electronic ballasts. The T5 lamp offers savings in terms of materials, packaging and shipping, as well as smaller fixtures with improved optical performance. Manufacturers are actively researching improvements in four critical areas that are expected to yield additional efficacy improvements of approximately 10 to 14 percent over the next five years, ultimately achieving approximately 130 lumens per watt by 2015. The active areas of research where these improvements are anticipated include: (1) Improved phosphors which continue to be developed and patented, enabling higher efficacies as well as better color rendering and lumen maintenance; (2) Enhanced fill gas - adjusting proportions of argon, krypton, neon and xenon to optimize performance, while also m

  3. astra tech fixture: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    A fixture O'Brien, James F. 43 Department of Mechanical Engineering Spring 2013 Lumax Lighting 2: LED Industrial High Bay Light Fixture Materials Science Websites Summary: was...

  4. Fixture for forming evaporative pattern (EPC) process patterns

    DOE Patents [OSTI]

    Turner, Paul C. (Albany, OR); Jordan, Ronald R. (Albany, OR); Hansen, Jeffrey S. (Corvallis, OR)

    1993-01-01T23:59:59.000Z

    A method of casting metal using evaporative pattern casting process patterns in combination with a fixture for creating and maintaining a desired configuration in flexible patterns. A pattern is constructed and gently bent to the curvature of a suitable fixture. String or thin wire, which burns off during casting, is used to tie the pattern to the fixture. The fixture with pattern is dipped in a commercially available refractory wash to prevent metal adherence and sticking to the fixture. When the refractory wash is dry, the fixture and pattern are placed in a flask, and sand is added and compacted by vibration. The pattern remains in position, restrained by the fixture. Metal that is poured directly into the pattern replaces the pattern exactly but does not contact or weld to the fixture due to the protective refractory layer. When solid, the casting is easily separated from the fixture. The fixture can be cleaned for reuse in conventional casting cleaning equipment.

  5. Plumbing fixture patterns through audio sampling

    E-Print Network [OSTI]

    Shea, Kevin Bruce

    2002-01-01T23:59:59.000Z

    was used to estimate maximal usage patterns and probabilities of the concurrent use of multiple water closets and urinals. Data was collected on the building's class population and schedule for comparisons to fixture use. The technique of multiple...

  6. ave lamp margareete: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Wm; Kaufmann, David E; Davis, Michael W; Versteeg, Maarten 2012-01-01 213 Study of the electrodeless discharge lamps for photochemical applications and temperature dependence of...

  7. Fluorescent Tube Lamps

    Broader source: Energy.gov [DOE]

    FEMP temporarily suspended its energy efficiency requirements for fluorescent tube lamps as it evaluates the market impact of the pending 2012 minimum efficiency standards for fluorescent lamps. The program will issue updated energy efficiency requirements when the market distribution of this product category stabilizes and when doing so has the potential to result in significant Federal energy savings.

  8. Turning on LAMP

    SciTech Connect (OSTI)

    Bostedt, Christoph

    2014-06-30T23:59:59.000Z

    Christoph Bostedt, a senior staff scientist at SLAC's Linac Coherent Light Source X-ray laser, provides a sneak peek of a powerful new instrument, called LAMP, that is now available for experiments that probe the atomic and molecular realm. LAMP replaces and updates the first instrument at LCLS, dubbed CAMP, which will be installed at an X-ray laser in Germany.

  9. Jacketed lamp bulb envelope

    DOE Patents [OSTI]

    MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD); Gitsevich, Aleksandr (Gaithersburg, MD); Bass, Gary K. (Mt. Airy, MD); Dolan, James T. (Frederick, MD); Kipling, Kent (Gaithersburg, MD); Kirkpatrick, Douglas A. (Great Falls, VA); Leng, Yongzhang (Damascus, MD); Levin, Izrail (Silver Spring, MD); Roy, Robert J. (Frederick, MD); Shanks, Bruce (Gaithersburg, MD); Smith, Malcolm (Alexandria, VA); Trimble, William C. (Columbia, MD); Tsai, Peter (Olney, MD)

    2001-01-01T23:59:59.000Z

    A jacketed lamp bulb envelope includes a ceramic cup having an open end and a partially closed end, the partially closed end defining an aperture, a lamp bulb positioned inside the ceramic cup abutting the aperture, and a reflective ceramic material at least partially covering a portion of the bulb not abutting the aperture. The reflective ceramic material may substantially fill an interior volume of the ceramic cup not occupied by the bulb. The ceramic cup may include a structural feature for aiding in alignment of the jacketed lamp bulb envelope in a lamp. The ceramic cup may include an external flange about a periphery thereof. One example of a jacketed lamp bulb envelope includes a ceramic cup having an open end and a closed end, a ceramic washer covering the open end of the ceramic cup, the washer defining an aperture therethrough, a lamp bulb positioned inside the ceramic cup abutting the aperture, and a reflective ceramic material filling an interior volume of the ceramic cup not occupied by the bulb. A method of packing a jacketed lamp bulb envelope of the type comprising a ceramic cup with a lamp bulb disposed therein includes the steps of filling the ceramic cup with a flowable slurry of reflective material, and applying centrifugal force to the cup to pack the reflective material therein.

  10. Turning on LAMP

    ScienceCinema (OSTI)

    Bostedt, Christoph

    2014-07-16T23:59:59.000Z

    Christoph Bostedt, a senior staff scientist at SLAC's Linac Coherent Light Source X-ray laser, provides a sneak peek of a powerful new instrument, called LAMP, that is now available for experiments that probe the atomic and molecular realm. LAMP replaces and updates the first instrument at LCLS, dubbed CAMP, which will be installed at an X-ray laser in Germany.

  11. Reflector system for a lighting fixture

    DOE Patents [OSTI]

    Siminovitch, Michael J. (829 Manor Rd., El Sobrante, CA 94803); Page, Erik (Berkeley, CA); Gould, Carl T. (Medford, OR)

    2001-01-01T23:59:59.000Z

    Disclosed herein is a reflector system for a lighting fixture having a illumination source surrounded by an envelope. The reflector system includes a first reflector surrounding the illumination source. The reflector system also includes a second reflector which is non-contiguous with the first reflector and which surrounds the illumination source. The illumination source creates light rays which are reflected by the first and second reflectors. The first reflector directs light rays toward the center line of the fixture. However, the reflected rays despite being so reflected do not substantially intersect the envelope. The reflected light rays from the second reflector being directed so that they diverge from the center line of the fixture avoiding intersection with the semi-transparent envelope.

  12. Reflector system for a lighting fixture

    DOE Patents [OSTI]

    Siminovitch, Michael J. (El Sobrante, CA); Page, Erik (Berkeley, CA); Gould, Carl T. (Medford, OR)

    1998-01-01T23:59:59.000Z

    Disclosed herein is a reflector system for a lighting fixture having a illumination source surrounded by an envelope. The reflector system includes a first reflector surrounding the illumination source. The reflector system also includes a second reflector which is non-contiguous with the first reflector and which surrounds the illumination source. The illumination source creates light rays which are reflected by the first and second reflectors. The first reflector directs light rays toward the center line of the fixture. However, the reflected rays despite being so reflected do not substantially intersect the envelope. The reflected light rays from the second reflector being directed so that they diverge from the center line of the fixture avoiding intersection with the semi-transparent envelope.

  13. Reflector system for a lighting fixture

    DOE Patents [OSTI]

    Siminovitch, M.J.; Page, E.; Gould, C.T.

    1998-09-08T23:59:59.000Z

    Disclosed herein is a reflector system for a lighting fixture having a illumination source surrounded by an envelope. The reflector system includes a first reflector surrounding the illumination source. The reflector system also includes a second reflector which is non-contiguous with the first reflector and which surrounds the illumination source. The illumination source creates light rays which are reflected by the first and second reflectors. The first reflector directs light rays toward the center line of the fixture. However, the reflected rays despite being so reflected do not substantially intersect the envelope. The reflected light rays from the second reflector being directed so that they diverge from the center line of the fixture avoiding intersection with the semi-transparent envelope. 5 figs.

  14. Magnetic fluorescent lamp

    DOE Patents [OSTI]

    Berman, S.M.; Richardson R.W.

    1983-12-29T23:59:59.000Z

    The radiant emission of a mercury-argon discharge in a fluorescent lamp assembly is enhanced by providing means for establishing a magnetic field with lines of force along the path of electron flow through the bulb of the lamp assembly, to provide Zeeman splitting of the ultraviolet spectral line. Optimum results are obtained when the magnetic field strength causes a Zeeman splitting of approximately 1.7 times the thermal line width.

  15. Covered Product Category: Light Fixtures (Luminaires)

    Broader source: Energy.gov [DOE]

    FEMP provides acquisition guidance and Federal efficiency requirements across a variety of product categories, including luminaires, or light fixtures. The luminaires product category is very broad and covers a wide variety of lighting products. Both ENERGY STAR® and FEMP provide programmatic guidance for various types of luminaires. See table 2 for more information about which types of light fixtures are covered by which program (FEMP or ENERGY STAR). Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

  16. Table lamp with dynamically controlled lighting distribution and uniformly illuminated luminous shade

    DOE Patents [OSTI]

    Siminovitch, Michael J. (Pinole, CA); Page, Erik R. (Berkeley, CA)

    2002-01-01T23:59:59.000Z

    A double lamp table or floor lamp lighting system has a pair of compact fluorescent lamps (CFLs) or other lamps arranged vertically, i.e. one lamp above the other, with a reflective septum in between. By selectively turning on one or both of the CFLs, down lighting, up lighting, or both up and down lighting is produced. The control system can also vary the light intensity from each CFL. The reflective septum ensures that almost all the light produced by each lamp will be directed into the desired light distribution pattern which is selected and easily changed by the user. In a particular configuration, the reflective septum is bowl shaped, with the upper CFL sitting in the bowl, and a luminous shade hanging down from the bowl. The lower CFL provides both task lighting and uniform shade luminance. Planar compact fluorescent lamps, e.g. circular CFLs, particularly oriented horizontally, are preferable. CFLs provide energy efficiency. However, other types of lamps, including incandescent, halogen, and LEDs can also be used in the fixture. The lighting system may be designed for the home, hospitality, office or other environments.

  17. Operating temperatures for a convectively cooled recessed incandescent light fixture

    SciTech Connect (OSTI)

    Yarbrough, D.W.; Toor, I.

    1980-12-01T23:59:59.000Z

    Test results are given for the operation of a recessed incandescent light fixture intended for residential use. The fixture is labeled for use in direct contact with attic thermal insulation. Temperature control of the powered fixture is provided by convective heat transfer from the ceiling side of the fixture. The fixture was operated at power levels up to two times the rated power of 75 watts and under thermal insulations up to R-40. In all operating configurations tested the fixture surface in contact with attic insulation was found to be less than 175/sup 0/C. The observed surface temperatures are judged to be safe for operation in contact with loose-fill or batt-type insulations. It was observed that the power leads inside one fixture configuration are exposed to temperatures as high as 168/sup 0/C. The electrical insulation could, therefore, have a limited life. The properties of the internal fixture wiring were not, however, studied in detail.

  18. Design of ultra precision fixtures for nano-manufacturing

    E-Print Network [OSTI]

    Mangudi Varadarajan, Kartik, 1981-

    2005-01-01T23:59:59.000Z

    This thesis presents the design, modeling, fabrication and experimental validation of an active precision fixturing system called the Hybrid Positioning Fixture (HPF). The HPF uses the principles of exact constraint, ...

  19. CALiPER Retail Lamps Study 3

    SciTech Connect (OSTI)

    Royer, Michael P.; Beeson, Tracy A.

    2014-02-01T23:59:59.000Z

    The CALiPER program first began investigating LED lamps sold at retail stores in 2010, purchasing 33 products from eight retailers and covering six product categories. The findings revealed a fragmented marketplace, with large disparities in performance of different products, accuracy of manufacturer claims, and offerings from different retail outlets. Although there were some good products, looking back many would not be considered viable competitors to other available options, with too little lumen output, not high enough efficacy, or poor color quality. CALiPER took another look in late 2011purchasing 38 products of five different types from nine retailers and the improvement was marked. Performance was up; retailer claims were more accurate; and the price per lumen and price per unit efficacy were down, although the price per product had not changed much. Nonetheless, there was still plenty of room for improvement, with the performance of LED lamps not yet reaching that of well-established classes of conventional lamps (e.g., 75 W incandescent A19 lamps). Since the second retail lamp study was published in early 2012, there has been substantial progress in all aspects of LED lamps available from retailers. To document this progress, CALiPER again purchased a sample of lamps from retail stores 46 products in total, focusing on A19, PAR30, and MR16 lamps but instead of a random sample, sought to select products to answer specific hypotheses about performance. These hypotheses focused on expanding ranges of LED equivalency, the accuracy of lifetime claims, efficacy and price trends, as well as changes to product designs. Among other results, key findings include: There are now very good LED options to compete with 60 W, 75 W, and 100 W incandescent A19 lamps, and 75 W halogen PAR30 lamps. MR16 lamps have shown less progress, but there are now acceptable alternatives to 35 W, 12 V halogen MR16 lamps and 50 W, 120 V halogen MR16 lamps for some applications. Other uses, such as in enclosed luminaires, may require more development. At the same price point, lamps purchased in 2013 tended to have higher output and slightly higher efficacy than in 2011 or 2010. Over 30% of the products purchased in 2013 exceeded the maximum efficacy measured in 2011 (71 lm/W), with the most efficacious product measured at 105 lm/W. There appears to be increasing consistency in color quality, with a vast majority of products having a CCT of 2700 K or 3000 K and a CRI between 80 and 85. There were also fewer poor performing products tested and more high-performing products available in 2013 than in previous years. The accuracy of equivalency and performance claims was better than in 2011, but remains a concern, with 43% of tested products failing to completely meet their equivalency claim and 20% of products failing to match the manufacturer’s performance data. Although progress has been substantial, on average LED lamps remain more expensive than other energy efficiency lighting technologies -- although some aspects can be superior. Although not universal to all product lines or all product types, the issue of insufficient lumen output from LED lamps is waning. Thus, manufacturers can focus on other issues, such as reducing cost, improving electrical/dimmer compatibility, eliminating flicker, or improving color quality. While these issues are not inherent to all products, they remain a concern for the broader market.

  20. Study of high frequency & low frequency electronic ballasts for HID lamps

    E-Print Network [OSTI]

    Peng, Hua

    1997-01-01T23:59:59.000Z

    High-intensity discharge (HID) lamp electronic ballasting is receiving increasing attention in the recent years as low wattage HID lighting systems are finding indoor applications. Advantages of high frequency electronic ballast for HID lamps...

  1. DOE Publishes CALiPER Report on LED T8 Lamps

    Broader source: Energy.gov [DOE]

    The U.S. Department of Energy's CALiPER program has released an Application Summary Report that focuses on the bare-lamp performance of 31 linear LED lamps intended as an alternative to T8...

  2. Assessment of user satisfaction of restrooms with existing toilet fixtures and new low consumption fixtures 

    E-Print Network [OSTI]

    Vankamamidi, Neelima Raman

    2004-11-15T23:59:59.000Z

    This research in Langford Building 'A', Texas A&M University, is an attempt to determine the user satisfaction of the new, low consumption toilet fixtures and lavatory valves. 253 surveys were given to the subjects, during ...

  3. Holding fixture for metallographic mount polishing

    DOE Patents [OSTI]

    Barth, C.H.; Cramer, C.E.

    1997-12-30T23:59:59.000Z

    A fixture is described for holding mounted specimens for polishing, having an arm; a body attached to one end of the arm, the body having at least one flange having an opening to accommodate a mounted specimen; and a means applying pressure against the outer surface of the mounted specimen to hold the specimen in contact with the polishing surface. 3 figs.

  4. Fixture for mounting small parts for processing

    DOE Patents [OSTI]

    Foreman, Larry R. (2456 36th St., Los Alamos, NM 87544); Gomez, Veronica M. (Rte. 5 Box 283, Santa Fe, NM 87501); Thomas, Michael H. (Rte. 3-193-1, Espanola, NM 87532)

    1990-01-01T23:59:59.000Z

    A fixture for mounting small parts, such as fusion target spheres or microelectronic components. A glass stalk is drawn and truncated near its tip. The truncated end of the glass stalk is dipped into silicone rubber forming an extending streamer. After the rubber cures for approximately 24 hours, a small part is touched to the streamer, and will be held securely throughout processing.

  5. LED MR16 Lamps

    Broader source: Energy.gov [DOE]

    The following CALiPER report provides detailed analysis of LED MR16 lamp performance, covering basic performance characteristics as well as subjective evaluation of beam, shadow, and color quality. Pending reports will offer analysis on performance attributes that are not captured by LM-79 testing. These reports are intended to educate the industry on market trends, potential issues, and important areas for improvement.

  6. Fixture for mounting small parts for processing

    DOE Patents [OSTI]

    Foreman, L.R.; Gomez, V.M.; Thomas, M.H.

    1990-05-29T23:59:59.000Z

    A fixture for mounting small parts, such as fusion target spheres or microelectronic components is disclosed. A glass stalk is drawn and truncated near its tip. The truncated end of the glass stalk is dipped into silicone rubber forming an extending streamer. After the rubber cures for approximately 24 hours, a small part is touched to the streamer, and will be held securely throughout processing. 5 figs.

  7. Processor and method for developing a set of admissible fixture designs for a workpiece

    DOE Patents [OSTI]

    Brost, Randolph C. (4204 Landau NE, Albuquerque, NM 87111); Goldberg, Kenneth Y. (1006 W. Edgeware Rd., Los Angeles, CA 90026); Wallack, Aaron S. (244 Wilson Way, Albany, CA 94710); Canny, John (Computer Science Division, 529 Soda Hall, Berkeley, CA 94720-1776)

    1996-01-01T23:59:59.000Z

    A fixture process and method is provided for developing a complete set of all admissible fixture designs for a workpiece which prevents the workpiece from translating or rotating. The fixture processor generates the set of all admissible designs based on geometric access constraints and expected applied forces on the workpiece. For instance, the fixture processor may generate a set of admissible fixture designs for first, second and third locators placed in an array of holes on a fixture plate and a translating clamp attached to the fixture plate for contacting the workpiece. In another instance, a fixture vice is used in which first, second, third and fourth locators are used and first and second fixture jaws are tightened to secure the workpiece. The fixture process also ranks the set of admissible fixture designs according to a predetermined quality metric so that the optimal fixture design for the desired purpose may be identified from the set of all admissible fixture designs.

  8. LED PAR38 Lamps

    Broader source: Energy.gov [DOE]

    The following CALiPER reports provide detailed analysis of LED PAR38 lamp performance, covering basic performance characteristics as well as subjective evaluation of beam, shadow, and color quality. Pending reports will offer analysis on flicker, dimming and power quality characteristics; stress testing; and lumen and chromaticity maintenance. These reports are intended to educate the industry on market trends, potential issues, and important areas for improvement.

  9. Side-by-Side Testing of Commercial Office Lighting Systems: Two-lamp Fluorescent Fixtures

    E-Print Network [OSTI]

    Parker, D. S.; Schrum, L.; Sonne, J. K.; Stedman, T. C.

    1996-01-01T23:59:59.000Z

    Lighting systems in commercial office buildings are primary determinants of building energy use. In warmer climates, lighting energy use has important implications for building cooling loads as well as those directly associated with illumination...

  10. New Energy Efficiency Standards for Metal Halide Lamp Fixtures to Save on

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO2:Introduction toManagement ofConverDynNet-Zero Campus atEnergy New EmployeeEnergy

  11. New Energy Efficiency Standards for Metal Halide Lamp Fixtures to Save on

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreaking ofOilNEW HAMPSHIREof Energy Investigates PortFreezers to SaveEnergy

  12. Emission and spectral characteristics of electrodeless indium halide lamp

    SciTech Connect (OSTI)

    Takeda, M.; Hochi, A.; Horii, S.; Matsuoka, T. [Matsushita Electric Industrial Co., Ltd., Kyoto (Japan). Lighting Research Lab.

    1997-12-31T23:59:59.000Z

    The electrodeless HID lamp excited by microwave has been intensively investigated because of its long life, high efficacy and environmental aspect. This study reports excellent emission and spectral characteristics of electrodeless HID lamp containing indium halides. The authors investigate InI and InBr as ingredients, and measure the microwave excited spectra and luminous intensities of lamps which are made from spherical silica glass in 10--40 mm outer diameter and with various amounts of halides. It is well known that such indium halides in the usual metal-halide lamps have strong blue line emission at 410 and 451nm. But, in the authors` microwave excited lamps, continuous spectrum can be observed in addition in the visible region. Increasing input of power of microwave makes this continuous spectrum stronger. Below 1kW microwave input power, the spectrum of InBr lamp almost resembled the CIE standard illuminant D65. As a consequence of the spectrum, they found that the color rendering and the duv of InBr lamp were excellent as high as 95 and smaller than 0.002, respectively, in the region of 400--800W input power. The efficacy higher than 100 lm/W was further achieved at 400W. The authors confirm that the microwave excited indium halides lamps can be applicable to many fields of lighting.

  13. Processor and method for developing a set of admissible fixture designs for a workpiece

    DOE Patents [OSTI]

    Brost, Randolph C. (4204 Landau NE., Albuquerque, NM 87111); Goldberg, Kenneth Y. (1006 W. Edgeware Rd., Los Angeles, CA 90026); Canny, John (Computer Science Division, 529 Soda Hall, UC Berkeley, CA 94720-1776); Wallack, Aaron S. (244 Wilson Way, Albany, CA 94710)

    1999-01-01T23:59:59.000Z

    Methods and apparatus are provided for developing a complete set of all admissible Type I and Type II fixture designs for a workpiece. The fixture processor generates the set of all admissible designs based on geometric access constraints and expected applied forces on the workpiece. For instance, the fixture processor may generate a set of admissible fixture designs for first, second and third locators placed in an array of holes on a fixture plate and a translating clamp attached to the fixture plate for contacting the workpiece. In another instance, a fixture vise is used in which first, second, third and fourth locators are used and first and second fixture jaws are tightened to secure the workpiece. The fixture process also ranks the set of admissible fixture designs according to a predetermined quality metric so that the optimal fixture design for the desired purpose may be identified from the set of all admissible fixture designs.

  14. Max Tech and Beyond: High-Intensity Discharge Lamps

    SciTech Connect (OSTI)

    Scholand, Michael

    2012-04-01T23:59:59.000Z

    High-intensity discharge (HID) lamps are most often found in industrial and commercial applications, and are the light source of choice in street and area lighting, and sports stadium illumination. HID lamps are produced in three types - mercury vapor (MV), high pressure sodium (HPS) and metal halide (MH). Of these, MV and MH are considered white-light sources (although the MV exhibits poor color rendering) and HPS produces a yellow-orange color light. A fourth lamp, low-pressure sodium (LPS), is not a HID lamp by definition, but it is used in similar applications and thus is often grouped with HID lamps. With the notable exception of MV which is comparatively inefficient and in decline in the US from both a sales and installed stock point of view; HPS, LPS and MH all have efficacies over 100 lumens per watt. The figure below presents the efficacy trends over time for commercially available HID lamps and LPS, starting with MV and LPS in 1930's followed by the development of HPS and MH in the 1960's. In HID lamps, light is generated by creating an electric arc between two electrodes in an arc tube. The particles in the arc are partially ionized, making them electrically conductive, and a light-emitting 'plasma' is created. This arc occurs within the arc tube, which for most HID lamps is enclosed within an evacuated outer bulb that thermally isolates and protects the hot arc tube from the surroundings. Unlike a fluorescent lamp that produces visible light through down-converting UV light with phosphors, the arc itself is the light source in an HID lamp, emitting visible radiation that is characteristic of the elements present in the plasma. Thus, the mixture of elements included in the arc tube is one critical factor determining the quality of the light emitted from the lamp, including its correlated color temperature (CCT) and color rendering index (CRI). Similar to fluorescent lamps, HID lamps require a ballast to start and maintain stable operating conditions, and this necessitates additional power beyond that used by the lamp itself. HID lamps offer important advantages compared to other lighting technologies, making them well suited for certain applications. HID lamps can be very efficient, have long operating lives, are relatively temperature-insensitive and produce a large quantity of light from a small package. For these reasons, HID lamps are often used when high levels of illumination are required over large areas and where operating and maintenance costs must be kept to a minimum. Furthermore, if the installation has a significant mounting height, high-power HID lamps can offer superior optical performance luminaires, reducing the number of lamps required to illuminate a given area. The indoor environments best suited to HID lamps are those with high ceilings, such as those commonly found in industrial spaces, warehouses, large retail spaces, sports halls and large public areas. Research into efficacy improvements for HID lighting technologies has generally followed market demand for these lamps, which is in decline for MV and LPS, has reached a plateau for HPS and is growing for MH. Several manufacturers interviewed for this study indicated that although solid-state lighting was now receiving the bulk of their company's R&D investment, there are still strong HID lamp research programs, which concentrate on MH technologies, with some limited amount of investment in HPS for specific niche applications (e.g., agricultural greenhouses). LPS and MV lamps are no longer being researched or improved in terms of efficacy or other performance attributes, although some consider MH HID lamps to be the next-generation MV lamp. Thus, the efficacy values of commercially available MV, LPS and HPS lamps are not expected to increase in the next 5 to 10 years. MH lamps, and more specifically, ceramic MH lamps are continuing to improve in efficacy as well as light quality, manufacturability and lamp life. Within an HID lamp, the light-producing plasma must be heated to sufficiently high temperatures to achieve high efficiencie

  15. An Algorithmic Approach to Fixturing New York University

    E-Print Network [OSTI]

    Mishra, Bud

    interest in manufacturing towards computer­ assisted production in small batch sizes, researchers have are related to the theory of dextrous manipulation in robotics, the problems in fixturing differ in two) The available fixtures are geometrically more specialized than robot­hands. 1. Introduction In manufacturing

  16. Text-Alternative Version: CALiPER Series 21 on LED Linear Lamps and Troffer Lighting

    Broader source: Energy.gov [DOE]

    Following is a text version of a video about CALiPER Application Report Series 21 on LED Linear Lamps and Troffer Lighting.

  17. High brightness microwave lamp

    DOE Patents [OSTI]

    Kirkpatrick, Douglas A.; Dolan, James T.; MacLennan, Donald A.; Turner, Brian P.; Simpson, James E.

    2003-09-09T23:59:59.000Z

    An electrodeless microwave discharge lamp includes a source of microwave energy, a microwave cavity, a structure configured to transmit the microwave energy from the source to the microwave cavity, a bulb disposed within the microwave cavity, the bulb including a discharge forming fill which emits light when excited by the microwave energy, and a reflector disposed within the microwave cavity, wherein the reflector defines a reflective cavity which encompasses the bulb within its volume and has an inside surface area which is sufficiently less than an inside surface area of the microwave cavity. A portion of the reflector may define a light emitting aperture which extends from a position closely spaced to the bulb to a light transmissive end of the microwave cavity. Preferably, at least a portion of the reflector is spaced from a wall of the microwave cavity. The lamp may be substantially sealed from environmental contamination. The cavity may include a dielectric material is a sufficient amount to require a reduction in the size of the cavity to support the desired resonant mode.

  18. Inductive tuners for microwave driven discharge lamps

    DOE Patents [OSTI]

    Simpson, James E. (Gaithersburg, MD)

    1999-01-01T23:59:59.000Z

    An RF powered electrodeless lamp utilizing an inductive tuner in the waveguide which couples the RF power to the lamp cavity, for reducing reflected RF power and causing the lamp to operate efficiently.

  19. automated fixture layout: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    is modified to increase the productivity. The new fixture design is carried out by using CATIA V5 modeling software and it is critically evaluated for the failure of piston rod...

  20. Frequency of plumbing fixture use through audio sampling

    E-Print Network [OSTI]

    Shea, Kevin Bruce

    2013-02-22T23:59:59.000Z

    FREQUENCY OF PLUMBING FIXTURE USE THROUGH AUDIO SAMPLING A Senior Honors Thesis By KEVIN BRUCE SHEA Submitted to the Office of Honors Programs & Academic Scholarships Texas ARM University In partial fulfillment of the requirements... of the UNIVERSITY UNDERGRADUATE RESEARCH FELLOWS April 2000 Group. Physical Sciences FREQUENCY OF PLUMBING FIXTURE USE THROUGH AUDIO SAMPLING A Senior Honors Thesis By KEVIN BRUCE SHEA Submitted to the Office of Honors Programs & Academic Scholarships...

  1. Max Tech and Beyond: High-Intensity Discharge Lamps

    E-Print Network [OSTI]

    Scholand, Michael

    2012-01-01T23:59:59.000Z

    light emitting diode (LED) lamps will eventually come toare also looking to make LED lamps compatible with standardelectronics design, an LED lamp can be made dimmable over a

  2. Microwave power spectral density and its effects on exciting electrodeless high intensity discharge lamps

    SciTech Connect (OSTI)

    Butler, S.J.; Goss, H.H.; Lapatovich, W.P. [Osram Sylvania Inc., Salem, MA (United States)

    1995-12-31T23:59:59.000Z

    The effects of a microwave source generating a spectrally dense power spectrum on the operation of an electrodeless high intensity discharge lamp were measured. Spectrally pure sources operating within ISM bands at 915 MHz and 2.45 GHz produce stable capacitively coupled discharges useful for producing flicker-free light for numerous applications. The internal plasma temperature distribution and lamp geometry define acoustic resonance modes within the lamp which can be excited with power sidebands. The operation of lamps with commercially available power sources and custom built generators are discussed. Estimates of the spectral purity required for stable operation are provided.

  3. High pressure neon arc lamp

    DOE Patents [OSTI]

    Sze, Robert C.; Bigio, Irving J.

    2003-07-15T23:59:59.000Z

    A high pressure neon arc lamp and method of using the same for photodynamic therapies is provided. The high pressure neon arc lamp includes a housing that encloses a quantity of neon gas pressurized to about 500 Torr to about 22,000 Torr. At each end of the housing the lamp is connected by electrodes and wires to a pulse generator. The pulse generator generates an initial pulse voltage to breakdown the impedance of the neon gas. Then the pulse generator delivers a current through the neon gas to create an electrical arc that emits light having wavelengths from about 620 nanometers to about 645 nanometers. A method for activating a photosensitizer is provided. Initially, a photosensitizer is administered to a patient and allowed time to be absorbed into target cells. Then the high pressure neon arc lamp is used to illuminate the target cells with red light having wavelengths from about 620 nanometers to about 645 nanometers. The red light activates the photosensitizers to start a chain reaction that may involve oxygen free radicals to destroy the target cells. In this manner, a high pressure neon arc lamp that is inexpensive and efficiently generates red light useful in photodynamic therapy is provided.

  4. Max Tech and Beyond: Fluorescent Lamps

    E-Print Network [OSTI]

    Scholand, Michael

    2012-01-01T23:59:59.000Z

    Laboratory, LBNL-4998E. General Electric Lamp and BallastEuropean Union General Electric High Intensity DischargeEnergy Saver”; and General Electric has a 26 watt T5 lamp (

  5. Welding fixture for nuclear fuel pin cladding assemblies

    DOE Patents [OSTI]

    Oakley, David J. (Richland, WA); Feld, Sam H. (West Richland, WA)

    1986-01-01T23:59:59.000Z

    A welding fixture for locating a driver sleeve about the open end of a nuclear fuel pin cladding. The welding fixture includes a holder provided with an open cavity having shoulders for properly positioning the driver sleeve, the end cap, and a soft, high temperature resistant plastic protective sleeve that surrounds a portion of the end cap stem. Ejected contaminant particles spewed forth by closure of the cladding by pulsed magnetic welding techniques are captured within a contamination trap formed in the holder for ultimate removal and disposal of contaminating particles along with the holder.

  6. Welding fixture for nuclear fuel pin cladding assemblies

    DOE Patents [OSTI]

    Oakley, D.J.; Feld, S.H.

    1984-02-22T23:59:59.000Z

    A welding fixture is described for locating a driver sleeve about the open end of a nuclear fuel pin cladding. The welding fixture includes a holder provided with an open cavity having shoulders for properly positioning the driver sleeve, the end cap, and a soft, high temperature resistant plastic protective sleeve that surrounds a portion of the end cap stem. Ejected contaminant particles spewed forth by closure of the cladding by pulsed magnetic welding techniques are captured within a contamination trap formed in the holder for ultimate removal and disposal of contaminating particles along with the holder.

  7. Comparison lamps automation CTIO 60 inches Echelle

    E-Print Network [OSTI]

    Tokovinin, Andrei A.

    Comparison lamps automation CTIO 60 inches Echelle ECH60S5.1 La Serena, December 09, 2009 #12)...............................................................................12 CTIO 60 inches Echelle / Comparison lamps automation, ECH60S5.1 2 #12;Introduction The present document is just a brief summary of the work done automating the 60 inches echelle comparison lamps

  8. Comparison lamps automation CTIO 60 inches CHIRON

    E-Print Network [OSTI]

    Tokovinin, Andrei A.

    Comparison lamps automation CTIO 60 inches CHIRON CHI60HF5.2 La Serena, March 16, 2011 #12;Table)...............................................................................12 CTIO 60 inches Chiron / Comparison lamps automation, CHI60HF5.2 2 #12;Introduction The present document is just a brief summary of the work done automating the 60 inches chiron comparison lamps

  9. LED Linear Lamps and Troffer Lighting

    Broader source: Energy.gov [DOE]

    The CALiPER program performed a series of investigations on linear LED lamps. Each report in the series covers the performance of up to 31 linear LED lamps, which were purchased in late 2012 or 2013. The first report focuses on bare lamp performance of LED T8 replacement lamps and subsequent reports examine performance in various troffers, as well as cost-effectiveness. There is also a concise guidance document that describes the findings of the Series 21 studies and provides practical advice to manufacturers, specifiers, and consumers (Report 21.4: Summary of Linear (T8) LED Lamp Testing , 5 pages, June 2014).

  10. Type of Space Bulb Type #/House Fixture Style Greenhouse #

    E-Print Network [OSTI]

    Pawlowski, Wojtek

    Type of Space Bulb Type #/House Fixture Style Greenhouse # 1 Lu 430/Lu 400 24 White box style 2 Lu No bulbs 0 N/A Seed harvest room F32 T8/TL 841 90 bulbs VIGS Room F032 /741/ECO 60 bulbs Chamber Model Bulb

  11. Applications of Cu{sub 2}O octahedral particles on ITO glass in photocatalytic degradation of dye pollutants under a halogen tungsten lamp

    SciTech Connect (OSTI)

    Zhai, Wei [School of Chemistry and Environment, South China Normal University, Guangzhou 510006 (China); Sun, Fengqiang, E-mail: fqsun@scnu.edu.cn [School of Chemistry and Environment, South China Normal University, Guangzhou 510006 (China); Key Laboratory of Theoretical Chemistry of Environment, Ministry of Education, South China Normal University (China); Exhibition Base of Production, Study and Research on New Polymer Materials and Postgraduate Students’ Innovation Training of Guangdong Higher Education Institutes (China); Chen, Wei; Zhang, Lihe; Min, Zhilin; Li, Weishan [School of Chemistry and Environment, South China Normal University, Guangzhou 510006 (China)

    2013-11-15T23:59:59.000Z

    Graphical abstract: - Highlights: • Photocatalytic activity of Cu{sub 2}O octahedral microcrystals on ITO glass was studied. • They showed high abilities in degradation of methylene blue in the presence of H{sub 2}O{sub 2}. • H{sub 2}O{sub 2} amount could affect the degradation efficiency. • Such particles could be easily recycled and still kept high activity. • Many dye pollutants and their mixtures could be efficiently degraded. - Abstract: Cu{sub 2}O octahedral microcrystals were prepared on the ITO glass by galvanostatic electrodeposition in CuSO{sub 4} solution with poly(vinylpryrrolidone) as the surfactant. By controlling the electrodeposition time, the microcrystals could be randomly distributed on the ITO glass and separated from each other, resulting in as many as possible (1 1 1) crystalline planes were exposed. Such microcrystals immobilized on ITO glass were employed in photodegradation of dye pollutants in the presence of H{sub 2}O{sub 2} under a 150 W halogen tungsten lamp. The photodegradation of methylene blue was taken as an example to evaluate the photocatalytic activities of the octahedral Cu{sub 2}O microcrystals. Effects of electrodeposition time and H{sub 2}O{sub 2} amount on the degradation efficiency was discussed, giving the optimum conditions and the corresponding degradation mechanism. The catalyst showed high ability in degradation of methylene blue, methyl orange, rhodamine B, eosin B and their mixtures under identical conditions.

  12. An Assessment of the U.S. Residential Lighting Market

    E-Print Network [OSTI]

    Jennings, Judy; Brown, Rich; Moezzi, Mithra; Mills, Evan; Sardinsky, Robert

    1995-01-01T23:59:59.000Z

    basis by fixture type and lamp wattage. The average lightingusage level, lamp wattage, fixture type, and location withinusage level, lamp wattage, fixture type, and location within

  13. Lamp with a truncated reflector cup

    DOE Patents [OSTI]

    Li, Ming; Allen, Steven C.; Bazydola, Sarah; Ghiu, Camil-Daniel

    2013-10-15T23:59:59.000Z

    A lamp assembly, and method for making same. The lamp assembly includes first and second truncated reflector cups. The lamp assembly also includes at least one base plate disposed between the first and second truncated reflector cups, and a light engine disposed on a top surface of the at least one base plate. The light engine is configured to emit light to be reflected by one of the first and second truncated reflector cups.

  14. LED Replacements for Linear Fluorescent Lamps Webcast

    Broader source: Energy.gov [DOE]

    In this June 20, 2011 webcast on LED products marketed as replacements for linear fluorescent lamps, Jason Tuenge of the Pacific Northwest National Laboratory (PNNL) discussed current Lighting...

  15. Covered Product Category: Compact Fluorescent Lamps

    Broader source: Energy.gov [DOE]

    FEMP provides acquisition guidance across a variety of product categories, including compact fluorescent lamps (CFLs), which are an ENERGY STAR-qualified product category.

  16. Lamp bulb with integral reflector

    DOE Patents [OSTI]

    Levin, Izrail (Silver Spring, MD); Shanks, Bruce (Gaithersburg, MD); Sumner, Thomas L. (Wheaton, MD)

    2001-01-01T23:59:59.000Z

    An improved electrodeless discharge lamp bulb includes an integral ceramic reflector as a portion of the bulb envelope. The bulb envelope further includes two pieces, a reflector portion or segment is cast quartz ceramic and a light transmissive portion is a clear fused silica. In one embodiment, the cast quartz ceramic segment includes heat sink fins or stubs providing an increased outside surface area to dissipate internal heat. In another embodiment, the quartz ceramic segment includes an outside surface fused to eliminate gas permeation by polishing.

  17. Note: Hollow cathode lamp with integral, high optical efficiency isolation valve: A modular vacuum ultraviolet source

    SciTech Connect (OSTI)

    Sloan Roberts, F.; Anderson, Scott L. [Department of Chemistry, University of Utah, 315 S. 1400 E., Salt Lake City, Utah 84112 (United States)] [Department of Chemistry, University of Utah, 315 S. 1400 E., Salt Lake City, Utah 84112 (United States)

    2013-12-15T23:59:59.000Z

    The design and operating conditions of a hollow cathode discharge lamp for the generation of vacuum ultraviolet radiation, suitable for ultrahigh vacuum (UHV) application, are described in detail. The design is easily constructed, and modular, allowing it to be adapted to different experimental requirements. A thin isolation valve is built into one of the differential pumping stages, isolating the discharge section from the UHV section, both for vacuum safety and to allow lamp maintenance without venting the UHV chamber. The lamp has been used both for ultraviolet photoelectron spectroscopy of surfaces and as a “soft” photoionization source for gas-phase mass spectrometry.

  18. Discharge lamp with reflective jacket

    DOE Patents [OSTI]

    MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD); Kipling, Kent (Gaithersburg, MD)

    2001-01-01T23:59:59.000Z

    A discharge lamp includes an envelope, a fill which emits light when excited disposed in the envelope, a source of excitation power coupled to the fill to excite the fill and cause the fill to emit light, and a reflector disposed around the envelope and defining an opening, the reflector being configured to reflect some of the light emitted by the fill back into the fill while allowing some light to exit through the opening. The reflector may be made from a material having a similar thermal index of expansion as compared to the envelope and which is closely spaced to the envelope. The envelope material may be quartz and the reflector material may be either silica or alumina. The reflector may be formed as a jacket having a rigid structure which does not adhere to the envelope. The lamp may further include an optical clement spaced from the envelope and configured to reflect an unwanted component of light which exited the envelope back into the envelope through the opening in the reflector. Light which can be beneficially recaptured includes selected wavelength regions, a selected polarization, and selected angular components.

  19. Solid-state lamp with integral occupancy sensor

    E-Print Network [OSTI]

    Cooley, John J.

    Previous work demonstrated a retrofit proximity detector for fluorescent lamps using the lamp's own stray electric fields. This paper extends the retrofit sensor system to a solid-state (LED) lamp. The design and implementation ...

  20. Portable lamp with dynamically controlled lighting distribution

    DOE Patents [OSTI]

    Siminovitch, Michael J. (Pinole, CA); Page, Erik R. (Berkeley, CA)

    2001-01-01T23:59:59.000Z

    A double lamp table or floor lamp lighting system has a pair of compact fluorescent lamps (CFLs) arranged vertically with a reflective septum in between. By selectively turning on one or both of the CFLs, down lighting, up lighting, or both up and down lighting is produced. The control system can also vary the light intensity from each CFL. The reflective septum insures that almost all the light produced by each lamp will be directed into the desired light distribution pattern which is selected and easily changed by the user. Planar compact fluorescent lamps, e.g. circular CFLs, particularly oriented horizontally, are preferable. CFLs provide energy efficiency. The lighting system may be designed for the home, hospitality, office or other environments.

  1. Max Tech and Beyond: High-Intensity Discharge Lamps

    E-Print Network [OSTI]

    Scholand, Michael

    2012-01-01T23:59:59.000Z

    Pressure Sodium Light Emitting Diode Lamp Lumen Depreciationit is expected that light emitting diode (LED) lamps willLED Technology Light emitting diodes (LEDs) are an emerging

  2. Cost effectiveness of long life incandescent lamps and energy buttons

    SciTech Connect (OSTI)

    Verderber, R.; Morse, O.

    1980-04-07T23:59:59.000Z

    Long-life replacement lamps for the incandescent lamp have been evaluated with regard to their cost effectiveness. The replacements include the use of energy buttons that extend lamp life as well as an adaptive fluorescent circline lamp that will fit into existing incandescent lamp sockets. The initial, operating, and replacement costs for one million lumen hours are determined for each lamp system. It is found that the most important component lighting cost is the operating cost. Using lamps that are less efficient or devices that cause lamps to operate less efficiently are not cost-effective. The adaptive fluorescent circline lamp, even at an initial unit cost of $20.00, is the most cost-effective source of illumination compared to the incandescent lamp and lamp systems examined.

  3. The electrical and lumen output characteristics of an RF lamp

    SciTech Connect (OSTI)

    Alexandrovich, B.M.; Godyak, V.A.; Piejak, R.B. [Osram Sylvania Inc., Beverly, MA (United States)

    1996-12-31T23:59:59.000Z

    Low pressure rf discharges have been studied for over a century. Their first practical application for lighting was proposed by Tesla in 1891. Since then hundreds of patents have been published attempting to implement rf lighting. However, progress in understanding rf discharge phenomena (mostly driven by plasma processing needs) and dramatic improvement in the performance/cost ratio of rf power sources have recently opened the door for development of rf light sources. Today commercial inductively coupled electrodeless lamps are offered by Matsuhita, Philips and GE. In this work the authors present measurements of the electrical characteristics and lumen output from a 2.65 MHz driven inductively coupled light source. Measurements were made on a spherical lamp of 3.125 inch diameter with a re-entrant cavity that houses a cylindrical ferrite core around which is wrapped the primary coil.

  4. Tungsten and tungsten alloy powder metallurgy: Powder production and applications excluding lamps. (Latest citations from the US Patent bibliographic file with exemplary claims). Published Search

    SciTech Connect (OSTI)

    Not Available

    1994-04-01T23:59:59.000Z

    The bibliography contains citations of selected patents concerning the preparation of metallic and ceramic powders of tungsten and tungsten alloys, including applications of these materials. The hydrogen reduction of tungsten compounds together with alloying element compounds produce forms with characteristics of high density, hardness, wear resistance, high melting points, and abrasiveness. Topics include production of cathodes, heaters, filament wires, electrical contacts, acoustic absorbers, high-density sheets and coatings, hard penetrators, and tungsten carbide and metallized ceramics. (Contains a minimum of 109 citations and includes a subject term index and title list.)

  5. Gas-source molecular beam epitaxial growth and characterization of the (Al,In,Ga)NP/GaP material system and Its applications to light-emitting diodes

    E-Print Network [OSTI]

    Odnoblyudov, Vladimir

    2006-01-01T23:59:59.000Z

    for indicator lamp application, but the LED structure can befor indicator lamp application, but the LED structure can beLEDs are the ultimate goal to replace incandescent and fluorescent lamps

  6. Department of Mechanical Engineering Spring 2013 Lumax Lighting 2: LED Industrial High Bay Light Fixture

    E-Print Network [OSTI]

    Demirel, Melik C.

    PENNSTATE Department of Mechanical Engineering Spring 2013 Lumax Lighting 2: LED Industrial High Bay Light Fixture Overview The problem that our sponsor, Rich Taylor, presented to the team was to design a light fixture for an industrial setting using high power LED lights. The challenge

  7. LED lamp power management system and method

    DOE Patents [OSTI]

    Gaines, James; Clauberg, Bernd; Van Erp, Josephus A. M.

    2013-03-19T23:59:59.000Z

    An LED lamp power management system and method including an LED lamp having an LED controller 58; a plurality of LED channels 60 operably connected to the LED controller 58, each of the plurality of LED channels 60 having a channel switch 62 in series with at least one shunted LED circuit 83, the shunted LED circuit 83 having a shunt switch 68 in parallel with an LED source 80. The LED controller 58 reduces power loss in one of the channel switch 62 and the shunt switch 68 when LED lamp electronics power loss (P.sub.loss) exceeds an LED lamp electronics power loss limit (P.sub.lim); and each of the channel switches 62 receives a channel switch control signal 63 from the LED controller 58 and each of the shunt switches 68 receives a shunt switch control signal 69 from the LED controller 58.

  8. High frequency inductive lamp and power oscillator

    DOE Patents [OSTI]

    MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD); Dolan, James T. (Frederick, MD); Kirkpatrick, Douglas A. (Great Falls, VA); Leng, Yongzhang (Damascus, MD)

    2000-01-01T23:59:59.000Z

    A high frequency inductively coupled electrodeless lamp includes an excitation coil with an effective electrical length which is less than one half wavelength of a driving frequency applied thereto, preferably much less. The driving frequency may be greater than 100 MHz and is preferably as high as 915 MHz. Preferably, the excitation coil is configured as a non-helical, semi-cylindrical conductive surface having less than one turn, in the general shape of a wedding ring. At high frequencies, the current in the coil forms two loops which are spaced apart and parallel to each other. Configured appropriately, the coil approximates a Helmholtz configuration. The lamp preferably utilizes an bulb encased in a reflective ceramic cup with a pre-formed aperture defined therethrough. The ceramic cup may include structural features to aid in alignment and/or a flanged face to aid in thermal management. The lamp head is preferably an integrated lamp head comprising a metal matrix composite surrounding an insulating ceramic with the excitation integrally formed on the ceramic. A novel solid-state oscillator preferably provides RF power to the lamp. The oscillator is a single active element device capable of providing over 70 watts of power at over 70% efficiency. Various control circuits may be employed to match the driving frequency of the oscillator to a plurality of tuning states of the lamp.

  9. Retail Lamps Study 3.1: Dimming, Flicker, and Power Quality Characteristics of LED A Lamps.

    SciTech Connect (OSTI)

    Royer, Michael P.; Poplawski, Michael E.; Brown, Charles C.

    2014-12-14T23:59:59.000Z

    To date, all three reports in the retail lamps series have focused on basic performance parameters, such as lumen output, efficacy, and color quality. This report goes a step further, examining the photoelectric characteristics (i.e., dimming and flicker) of a subset of lamps from CALiPER Retails Lamps Study 3. Specifically, this report focuses on the dimming, power quality, and flicker characteristics of 14 LED A lamps, as controlled by four different retail-available dimmers. The results demonstrate notable variation across the various lamps, but little variation between the four dimmers. Overall, the LED lamps: ~tended to have higher relative light output compared to the incandescent and halogen benchmark at the same dimmer output signal (RMS voltage). The lamps’ dimming curves (i.e., the relationship between control signal and relative light output) ranged from linear to very similar to the square-law curve typical of an incandescent lamp. ~generally exhibited symmetrical behavior—the same dimming curve—when measured proceeding from maximum to minimum or minimum to maximum control signal. ~mostly dimmed below 10% of full light output, with some exceptions for specific lamp and dimmer combinations ~exhibited a range of flicker characteristics, with many comparing favorably to the level typical of a magnetically-ballasted fluorescent lamp through at least a majority of the dimming range. ~ always exceeded the relative (normalized) efficacy over the dimming range of the benchmark lamps, which rapidly decline in efficacy when they are dimmed. This report generally does not attempt to rank the performance of one product compared to another, but instead focuses on the collective performance of the group versus conventional incandescent or halogen lamps, the performance of which is likely to be the baseline for a majority of consumers. Undoubtedly, some LED lamps perform better—or more similar to conventional lamps—than others. Some perform desirably for one characteristic, but not others. Consumers (and specifiers) may have a hard time distinguishing better-performing lamps from one another; at this time, physical experimentation is likely the best evaluation tool.

  10. 6035 Hg(Ar) Lamp in 6058 Fiber Optic Accessory. Pencil Style Calibration Lamps

    E-Print Network [OSTI]

    Woodall, Jerry M.

    to that of the Hg(Ar) Lamp, which is the characteristic mercury line spectrum. Forced air-cooling (i.e. from of the handle for connection to the power supply. Table 1 Usable Wavelengths of Spectral Calibration Lamps (in.2 1079.8 1084.5 1114.3 Power Supplies; AC versus DC We offer different power supplies for different needs

  11. iLamp: A Sensor-Enhanced Lamp with Surface-Tracking Capability Based on Light

    E-Print Network [OSTI]

    Tseng, Yu-Chee

    . The lamp has a robot arm and some LEDs as light sources. When finding that the sensed light intensity robot arm, to a better location and then adjust its LEDs to satisfy the bookmark's need. Central to our interface. This lamp is composed of a ZigBee module, a microprocessor, and a robot arm holding four sets

  12. High frequency inductive lamp and power oscillator

    DOE Patents [OSTI]

    MacLennan, Donald A. (Gaithersburg, MD); Dymond, Jr., Lauren E. (North Potomac, MD); Gitsevich, Aleksandr (Montgomery Village, MD); Grimm, William G. (Silver Spring, MD); Kipling, Kent (Gaithersburg, MD); Kirkpatrick, Douglas A. (Great Falls, VA); Ola, Samuel A. (Silver Spring, MD); Simpson, James E. (Gaithersburg, MD); Trimble, William C. (Columbia, MD); Tsai, Peter (Olney, MD); Turner, Brian P. (Damascus, MD)

    2001-01-01T23:59:59.000Z

    A high frequency inductively coupled electrodeless lamp includes an excitation coil with an effective electrical length which is less than one half wavelength of a driving frequency applied thereto, preferably much less. The driving frequency may be greater than 100 MHz and is preferably as high as 915 MHz. Preferably, the excitation coil is configured as a non-helical, semi-cylindrical conductive surface having less than one turn, in the general shape of a wedding ring. At high frequencies, the current in the coil forms two loops which are spaced apart and parallel to each other. Configured appropriately, the coil approximates a Helmholtz configuration. The lamp preferably utilizes an bulb encased in a reflective ceramic cup with a pre-formed aperture defined therethrough. The ceramic cup may include structural features to aid in alignment and I or a flanged face to aid in thermal management. The lamp head is preferably an integrated lamp head comprising a metal matrix composite surrounding an insulating ceramic with the excitation integrally formed on the ceramic. A novel solid-state oscillator preferably provides RF power to the lamp. The oscillator is a single active element device capable of providing over 70 watts of power at over 70% efficiency. Various control circuits may be employed to adjust the driving frequency of the oscillator.

  13. EIGHTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE

    SciTech Connect (OSTI)

    Daugherty, W. L.

    2013-09-03T23:59:59.000Z

    A series of experiments to monitor the aging performance of Viton® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. Seventy tests using mock-ups of 9975 Primary Containment Vessels (PCVs) were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determine if they meet the criterion of leak-tightness defined in ANSI standard N14.5-97. Fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF. High temperature aging continues for 23 GLT O-ring fixtures at 200 – 270 ºF. Room temperature leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 ºF and higher temperatures, and in 8 fixtures aging at 300 ºF. The remaining GLT O-ring fixtures aging at 300 ºF have been retired from testing following more than 5 years at temperature without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 ºF for 61 - 85 months, which is still bounding to O-ring temperatures during storage in KArea Complex (KAC). Based on expectations that the fixtures aging at 200 ºF will remain leaktight for a significant period yet to come, 2 additional fixtures began aging in 2011 at an intermediate temperature of 270 ºF, with hopes that they may reach a failure condition before the 200 ºF fixtures. High temperature aging continues for 6 GLT-S O-ring fixtures at 200 – 300 ºF. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 ºF. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 - 300 ºF for 41 - 45 months. Aging and periodic leak testing will continue for the remaining PCV fixtures.

  14. Integrated calibration sphere and calibration step fixture for improved coordinate measurement machine calibration

    DOE Patents [OSTI]

    Clifford, Harry J. (Los Alamos, NM)

    2011-03-22T23:59:59.000Z

    A method and apparatus for mounting a calibration sphere to a calibration fixture for Coordinate Measurement Machine (CMM) calibration and qualification is described, decreasing the time required for such qualification, thus allowing the CMM to be used more productively. A number of embodiments are disclosed that allow for new and retrofit manufacture to perform as integrated calibration sphere and calibration fixture devices. This invention renders unnecessary the removal of a calibration sphere prior to CMM measurement of calibration features on calibration fixtures, thereby greatly reducing the time spent qualifying a CMM.

  15. Electrodeless lamp energized by microwave energy

    SciTech Connect (OSTI)

    Ervin, R.M.; Perret, J.

    1990-01-16T23:59:59.000Z

    This patent describes an electrodeless lamp. It comprises: a microwave cavity; a source of microwaves in communication with the cavity; a lamp envelope containing a plasma-forming medium mounted within the microwave cavity; a gas manifold for feeding gas to at least one gas passageway for directing a stream of gas to the outer surface of the envelope; a gas leak passageway leading from the gas manifold; a conductive mesh assembly for retaining microwaves within the cavity and permitting light to be emitted from the cavity. The assembly including gas flow blocking means for preventing the flow of gas through the gas leak passageway when the screen is in place in the lamp; and means for shutting off the source of microwaves when the gas pressure in the manifold drops below a predetermined value.

  16. IEEE Power Electronics Specialists Conference, PESC-97, 39-45, St. Louis, 1997. A MHz Electronic Ballast for Automotive-Type HID Lamps

    E-Print Network [OSTI]

    Ballast for Automotive-Type HID Lamps Michael Gulko and Sam Ben-Yaakov* Power Electronics Laboratory lamps designated for automotive headlight applications was investigated theoretically, by simulation and experimentally. The study reveals that a based ballast (CS-PPRI) complies with the automotive requirement of very

  17. Near optimal design of fixture layouts in multi-station assembly processes

    E-Print Network [OSTI]

    Kim, Pansoo

    2004-11-15T23:59:59.000Z

    -station design may have high dimensions of design space, which can contain a lot of local optima. In this dissertation, I investigated two algorithms for optimal fixture layout designs. The first algorithm is an exchange algorithm, which was originally...

  18. On the development of a universal automated fixturing system through encapsulation techniques

    E-Print Network [OSTI]

    Lee, Elmer C., 1973-

    2001-01-01T23:59:59.000Z

    Universal automated fixturing can transform a machine tool into a rapid prototyping machine with many advantages over current rapid prototyping methods. Using this modified machine tool, prototype parts can be manufactured ...

  19. Laboratory Evaluation of LED T8 Replacement Lamp Products

    SciTech Connect (OSTI)

    Richman, Eric E.; Kinzey, Bruce R.; Miller, Naomi J.

    2011-05-23T23:59:59.000Z

    A report on a lab setting analysis involving LED lamps intended to directly replace T8 fluorescent lamps (4') showing light output, power, and economic comparisons with other fluorescent options.

  20. Text-Alternative Version: LED Replacements for Linear Fluorescent Lamps

    Broader source: Energy.gov [DOE]

    Below is the text-alternative version of the "LED Replacements for Linear Fluorescent Lamps" webcast, held June 20, 2011.

  1. Modelling of a Fluorescent Lamp Plasma

    E-Print Network [OSTI]

    Eindhoven, Technische Universiteit

    Technische Universiteit Eindhoven, op gezag van de Rector Magnificus, prof.dr. R.A. van Santen, voor een TECHNISCHE UNIVERSITEIT EINDHOVEN Hartgers, Albertus Modelling of a Fluorescent Lamp Plasma / by Albertus Hartgers. - Eindhoven : Technische Universiteit Eindhoven, 2003. - Proefschrift. ISBN 90-386-1665-1 NUR 924

  2. Modelling Additive Transport in Metal Halide Lamps

    E-Print Network [OSTI]

    Eindhoven, Technische Universiteit

    doctor aan de Technische Universiteit Eindhoven, op gezag van de Rector Magnificus, prof.dr.ir. C.J. van-DATA LIBRARY TECHNISCHE UNIVERSITEIT EINDHOVEN Beks, Mark Louwrens Modelling Additive Transport in Metal Halide Lamps/ door Beks, M.L. - Eindhoven : Technische Universiteit Eindhoven, 2008. Proefschrift. ISBN: 978

  3. Modeling of highly loaded fluorescent lamps

    SciTech Connect (OSTI)

    Lister, G.G.; Lawler, J.E.; Curry, J.J.

    1999-07-01T23:59:59.000Z

    Numerical modeling of the positive column of fluorescent lamps under conditions of high current density are of current interest, particularly in view of recent developments in electrodeless lamps. Current models tend to overestimate radiation output, and consequently the maintenance electric field in these discharges. Under highly loaded conditions, mercury-rare gas fluorescent lamps exhibit strong mercury depletion on axis (cataphoresis), and an understanding of resonance radiation transport under these conditions is therefore vital to the development of models with a predictive capability. The authors have explored the effect of radial cataphoresis on resonance radiation trapping for situations in which the radiation transport is dominated by foreign gas broadening, Doppler broadening, or resonance collisional broadening of the spectral line. Several different production rates per unit volume of resonance (excited) atoms have also been studied. It is advantageous in many cases to parameterize the trapped decay rate in terms of the total number of ground state atoms in the positive column independent of their radial distribution. The results of this work have been included in a numerical model of the positive column and the predicted influence on discharge parameters will be presented for cases of interest to highly loaded lamps.

  4. Controlling the vapor pressure of a mercury lamp

    DOE Patents [OSTI]

    Grossman, Mark W. (Belmont, MA); George, William A. (Rockport, MA)

    1988-01-01T23:59:59.000Z

    The invention described herein discloses a method and apparatus for controlling the Hg vapor pressure within a lamp. This is done by establishing and controlling two temperature zones within the lamp. One zone is colder than the other zone. The first zone is called the cold spot. By controlling the temperature of the cold spot, the Hg vapor pressure within the lamp is controlled. Likewise, by controlling the Hg vapor pressure of the lamp, the intensity and linewidth of the radiation emitted from the lamp is controlled.

  5. SEVENTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE

    SciTech Connect (OSTI)

    Daugherty, W.

    2012-08-30T23:59:59.000Z

    A series of experiments to monitor the aging performance of Viton® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. Seventy tests using mock-ups of 9975 Primary Containment Vessels (PCVs) were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determine if they meet the criterion of leak-tightness defined in ANSI standard N14.5-97. Fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF. High temperature aging continues for 23 GLT O-ring fixtures at 200 – 270 ºF. Room temperature leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 ºF and higher temperatures, and in 8 fixtures aging at 300 ºF. The remaining GLT O-ring fixtures aging at 300 ºF have been retired from testing following more than 5 years at temperature without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 ºF for 54-72 months, which is still bounding to O-ring temperatures during storage in K-Area Complex (KAC). Based on expectations that the fixtures aging at 200 ºF will remain leak-tight for a significant period yet to come, 2 additional fixtures began aging in 2011 at an intermediate temperature of 270 ºF, with hopes that they may reach a failure condition before the 200 ºF fixtures. High temperature aging continues for 6 GLT-S O-ring fixtures at 200 – 300 ºF. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 ºF. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 - 300 ºF for 30 - 36 months. For O-ring fixtures that have failed the room temperature leak test and been disassembled, the O-rings displayed a compression set ranging from 51 – 96%. This is greater than seen to date for any packages inspected during KAC field surveillance (24% average). For GLT O-rings, separate service life estimates have been made based on the O-ring fixture leak test data and based on compression stress relaxation (CSR) data. These two predictive models show reasonable agreement at higher temperatures (350 – 400 ºF). However, at 300 ºF, the room temperature leak test failures to date experienced longer aging times than predicted by the CSRbased model. This suggests that extrapolations of the CSR model predictions to temperatures below 300 ºF will provide a conservative prediction of service life relative to the leak rate criterion. Leak test failure data at lower temperatures are needed to verify this apparent trend. Insufficient failure data exist currently to perform a similar comparison for GLT-S O-rings. Aging and periodic leak testing will continue for the remaining PCV O-ring fixtures.

  6. NINTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE

    SciTech Connect (OSTI)

    Daugherty, W.

    2014-08-06T23:59:59.000Z

    A series of experiments to monitor the aging performance of Viton® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperatures. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF. High temperature aging continues for 23 GLT O-ring fixtures at 200 – 270 ºF. Room temperature leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 ºF and higher temperatures, and in 8 fixtures aging at 300 ºF. The earliest 300 °F GLT O-ring fixture failure was observed at 34 months. The remaining GLT O-ring fixtures aging at 300 ºF have been retired from testing following more than 5 years at temperature without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 ºF for 72 - 96 months, which bounds O-ring temperatures anticipated during storage in K-Area Complex (KAC). Based on expectations that the 200 ºF fixtures will remain leak-tight for a significant period yet to come, 2 additional fixtures began aging in 2011 at 270 ºF, with hopes that they may reach a failure condition before the 200 ºF fixtures, thus providing additional time to failure data. High temperature aging continues for 6 GLT-S O-ring fixtures at 200 – 300 ºF. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 ºF. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 - 300 ºF for 54 - 57 months. No additional O-ring failures have been observed since the last interim report was issued. Aging and periodic leak testing will continue for the remaining PCV fixtures. Additional irradiation of several fixtures is recommended to maintain a balance between thermal and radiation exposures similar to that experienced in storage, and to show the degree of consistency of radiation response between GLT and GLT-S O-rings.

  7. LED lamp color control system and method

    DOE Patents [OSTI]

    Gaines, James; Clauberg, Bernd; Van Erp, Josephus A.M.

    2013-02-05T23:59:59.000Z

    An LED lamp color control system and method including an LED lamp having an LED controller 58; and a plurality of LED channels 60 operably connected to the LED controller 58, each of the plurality of LED channels 60 having a channel switch 62 in series with at least one shunted LED circuit 83, the shunted LED circuit 83 having a shunt switch 68 in parallel with an LED source 80. The LED controller 58 determines whether the LED source 80 is in a feedback controllable range, stores measured optical flux for the LED source 80 when the LED source 80 is in the feedback controllable range, and bypasses storing the measured optical flux when the LED source 80 is not in the feedback controllable range.

  8. Lamp method and apparatus using multiple reflections

    DOE Patents [OSTI]

    MacLennan, D.A.; Turner, B.; Kipling, K.

    1999-05-11T23:59:59.000Z

    A method wherein the light in a sulfur or selenium lamp is reflected through the fill a multiplicity of times to convert ultraviolet radiation to visible is disclosed. A light emitting device comprised of an electrodeless envelope which bears a light reflecting covering around a first portion which does not crack due to differential thermal expansion and which has a second portion which comprises a light transmissive aperture. 20 figs.

  9. Lamp method and apparatus using multiple reflections

    DOE Patents [OSTI]

    MacLennan, Donald A. (Butler, PA); Turner, Brian (Damascus, MD); Kipling, Kent (Gaithersburg, MD)

    1999-01-01T23:59:59.000Z

    A method wherein the light in a sulfur or selenium lamp is reflected through the fill a multiplicity of times to convert ultraviolet radiation to visible. A light emitting device comprised of an electrodeless envelope which bears a light reflecting covering around a first portion which does not crack due to differential thermal expansion and which has a second portion which comprises a light transmissive aperture.

  10. FIFTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE

    SciTech Connect (OSTI)

    Daugherty, W.; Hoffman, E.

    2010-11-01T23:59:59.000Z

    A series of experiments to monitor the aging performance of Viton{sup reg.} GLT O-rings used in the Model 9975 package has been ongoing for six years at the Savannah River National Laboratory. Sixty-seven mock-ups of 9975 Primary Containment Vessels (PCVs) were assembled and heated to temperatures ranging from 200 to 450 F. They were leak-tested initially and have been tested at nominal six month intervals to determine if they meet the criterion of leaktightness defined in ANSI standard N14.5-97. Fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 F. High temperature aging continues for 36 GLT O-ring fixtures at 200--350 F. Room temperature leak test failures have been experienced in 5 of the GLT O-ring fixtures aging at 300 and 350 F, and in all 3 of the GLT O-ring fixtures aging at higher temperatures. No failures have yet been observed in GLT O-ring fixtures aging at 200 F for 30--48 months, which is still bounding to O-ring temperatures during storage in KAMS. High temperature aging continues for 6 GLT-S O-ring fixtures at 200--300 F. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 F. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 or 300 F for 19 months. For O-ring fixtures that have failed the room temperature leak test and been disassembled, the O-rings displayed a compression set ranging from 51--95%. This is significantly greater than seen to date for packages inspected during KAMS field surveillance (23% average). For GLT O-rings, service life based on the room temperature leak rate criterion is comparable to that predicted by compression stress relaxation (CSR) data at higher temperatures (350--400 F). While there are no comparable failure data yet at aging temperatures below 300 F, extrapolations of the data for GLT O-rings suggests that CSR model predictions provide a conservative prediction of service life relative to the leak rate criterion. Failure data at lower temperatures is needed to verify this apparent trend. Insufficient failure data exist currently to perform a similar comparison for GLT-S O-rings. Aging and periodic leak testing will continue for the remaining fixtures.

  11. Electrodeless lamp using a single magnetron and improved lamp envelope therefor

    SciTech Connect (OSTI)

    Ury, M. G.; Ryan, P. J.; Wood, Ch. H.

    1985-03-12T23:59:59.000Z

    A microwave generated electrodeless lamp using a single magnetron, and an improved lamp envelope therefor. An elongated lamp envelope containing a plasma forming medium is disposed in a microwave chamber comprised of a reflector and mesh. The reflector includes a pair of coupling slots, each of which is disposed equidistant from the ends of the lamp envelope. A waveguide means is provided which has a wall which is comprised of a portion of the reflector which includes the slots, and has means for introducing microwave energy thereto at an area equidistant from the two slots so that the energy couples equally to the slots. When the frequency of the microwave energy and chamber dimensions are arranged so that a symmetrical standing wave exists in the chamber, a balanced system results wherein after a short start-up period, approximately equal light output is obtained from the respective ends of the lamp envelop. In order to prevent recondensation of the envelope fill during operation at areas of low temperature, and improved envelope is provided in which such areas are severly tapered to cause hotter operation thereat.

  12. High output lamp with high brightness

    DOE Patents [OSTI]

    Kirkpatrick, Douglas A. (Great Falls, VA); Bass, Gary K. (Mt. Airy, MD); Copsey, Jesse F. (Germantown, MD); Garber, Jr., William E. (Poolesville, MD); Kwong, Vincent H. (Vancouver, CA); Levin, Izrail (Silver Spring, MD); MacLennan, Donald A. (Gaithersburg, MD); Roy, Robert J. (Frederick, MD); Steiner, Paul E. (Olney, MD); Tsai, Peter (Olney, MD); Turner, Brian P. (Damascus, MD)

    2002-01-01T23:59:59.000Z

    An ultra bright, low wattage inductively coupled electrodeless aperture lamp is powered by a solid state RF source in the range of several tens to several hundreds of watts at various frequencies in the range of 400 to 900 MHz. Numerous novel lamp circuits and components are disclosed including a wedding ring shaped coil having one axial and one radial lead, a high accuracy capacitor stack, a high thermal conductivity aperture cup and various other aperture bulb configurations, a coaxial capacitor arrangement, and an integrated coil and capacitor assembly. Numerous novel RF circuits are also disclosed including a high power oscillator circuit with reduced complexity resonant pole configuration, parallel RF power FET transistors with soft gate switching, a continuously variable frequency tuning circuit, a six port directional coupler, an impedance switching RF source, and an RF source with controlled frequency-load characteristics. Numerous novel RF control methods are disclosed including controlled adjustment of the operating frequency to find a resonant frequency and reduce reflected RF power, controlled switching of an impedance switched lamp system, active power control and active gate bias control.

  13. Automatic flush valve performance (gallons per flush) measured from fixtures in a mixed-use classroom/office building at Texas A&M University

    E-Print Network [OSTI]

    Lertbannaphong, Salilla

    2005-08-29T23:59:59.000Z

    flush valve performance (gpf) of fixtures in a mixed use classroom building at Texas A&M University. Water consumption (gpf) among three types of fixtures; low-consumption manual, old optic automatic and improved optic automatic systems are measured...

  14. Design and engineering of low-cost centimeter-scale repeatable and accurate kinematic fixtures for nanomanufacturing equipment using magnetic preload and potting

    E-Print Network [OSTI]

    Watral, Adrienne

    2011-01-01T23:59:59.000Z

    This paper introduces a low-cost, centimeter-scale kinematic coupling fixture for use in nanomanufacturing equipment. The fixture uses magnetic circuit design techniques to optimize the magnetic preload required to achieve ...

  15. arc lamp heal: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Cultures) -- (Animal Behaviour Wang, Yan 40 Spatial and time-dependent distribution of plasma parameters in the metal-halide arc lamp. Physics Websites Summary: for the...

  16. Fluorescent lamp unit with magnetic field generating means

    DOE Patents [OSTI]

    Grossman, M.W.; George, W.A.

    1989-08-08T23:59:59.000Z

    A fluorescent lamp unit having a magnetic field generating means for improving the performance of the fluorescent lamp is disclosed. In a preferred embodiment the fluorescent lamp comprises four longitudinally extending leg portions disposed in substantially quadrangular columnar array and joined by three generally U-shaped portions disposed in different planes. In another embodiment of the invention the magnetic field generating means comprises a plurality of permanent magnets secured together to form a single columnar structure disposed within a centrally located region defined by the shape of lamp envelope. 4 figs.

  17. RF driven sulfur lamp having driving electrodes arranged to cool the lamp

    DOE Patents [OSTI]

    Gabor, George (820 Skywood Rd., Lafayette, CA 94549); Orr, Thomas Robert (2285 Vestal, Castro Valley, CA 94546); Greene, Charles Maurice (6450 Regent St., Oakland, CA 94618); Crawford, Douglas Gordon (33 Longridge Rd., Orinda, CA 94563); Berman, Samuel Maurice (2832 Union St., San Francisco, CA 94123)

    1998-01-01T23:59:59.000Z

    A high intensity discharge lamp without mercury is disclosed radiating a selected spectrum of which can be almost entirely in the visible range from an envelope that contains a sulfur containing substance. The lamp utilizes a signal source that generates an excitation signal that is externally coupled to the exterior surface of the envelope to excite the enclosed sulfur containing substance. Various embodiments of the lamp use electrodes adjacent the envelope to couple the excitation signal thereto with the face of the electrodes shaped to complement the shape of the exterior surface of the envelope. Two shapes discussed are spherical and cylindrical. To minimize filamentary discharges each envelope may include an elongated stem affixed to the exterior thereof whereby a rotational subsystem spins the envelope. In yet another embodiment the envelope has a Dewar configuration with two electrodes, one positioned near the external curved side surface of the body, and a second to the inner surface of the hole through the envelope. Further, the envelope may contain a backfill of a selected inert gas to assist in the excitation of lamp with that backfill at a pressure of less than 1 atmosphere, wherein the backfill pressure is directly related to the increase or decrease of peak output and inversely related to the increase and decrease of the emitted spectrum from the envelope. The emitting fill can be less than 6 mg/cc, or at least 2 mg/cc of the envelope of a sulfur containing substance.

  18. RF driven sulfur lamp having driving electrodes arranged to cool the lamp

    DOE Patents [OSTI]

    Gabor, G.; Orr, T.R.; Greene, C.M.; Crawford, D.G.; Berman, S.M.

    1998-10-20T23:59:59.000Z

    A high intensity discharge lamp without mercury is disclosed radiating a selected spectrum of which can be almost entirely in the visible range from an envelope that contains a sulfur containing substance. The lamp utilizes a signal source that generates an excitation signal that is externally coupled to the exterior surface of the envelope to excite the enclosed sulfur containing substance. Various embodiments of the lamp use electrodes adjacent the envelope to couple the excitation signal thereto with the face of the electrodes shaped to complement the shape of the exterior surface of the envelope. Two shapes discussed are spherical and cylindrical. To minimize filamentary discharges each envelope may include an elongated stem affixed to the exterior thereof whereby a rotational subsystem spins the envelope. In yet another embodiment the envelope has a Dewar configuration with two electrodes, one positioned near the external curved side surface of the body, and a second to the inner surface of the hole through the envelope. Further, the envelope may contain a backfill of a selected inert gas to assist in the excitation of lamp with that backfill at a pressure of less than 1 atmosphere, wherein the backfill pressure is directly related to the increase or decrease of peak output and inversely related to the increase and decrease of the emitted spectrum from the envelope. The emitting fill can be less than 6 mg/cc, or at least 2 mg/cc of the envelope of a sulfur containing substance. 17 figs.

  19. Compact microwave lamp having a tuning block and a dielectric located in a lamp cavity

    DOE Patents [OSTI]

    Simpson, James E. (Gaithersburg, MD)

    2000-01-01T23:59:59.000Z

    A microwave lamp having a compact structure utilizing a coupling slot which has a dielectric member extending therethrough and a tuning block adjoining the coupling slot. A non-conventional waveguide is used which has about the width of a WR-284 waveguide and about the length of a WR-340 waveguide.

  20. The frequency of total use of manual and automatic low-consumption fixtures in the Langford Architecture Building at Texas A&M University

    E-Print Network [OSTI]

    Chung, Woo Sung

    2006-10-30T23:59:59.000Z

    . The performance of low-consumption fixtures has become an important issue for facilities managers because the water saving by retrofitting low-consumption fixtures is significant. The fixtures in the Langford Architecture Building A, Texas A&M University were used...

  1. Jim Duckworth, WPI Verilog for Testing -Module 61 Test Benches (Test Fixtures)

    E-Print Network [OSTI]

    Huang, Xinming

    Jim Duckworth, WPI Verilog for Testing - Module 61 Test Benches (Test Fixtures) Verilog for Testing #12;Jim Duckworth, WPI Verilog for Testing - Module 62 Overview · We have concentrated on Verilog for synthesis · Can also use Verilog as a test language · Very important to conduct comprehensive verification

  2. Lamp for generating high power ultraviolet radiation

    DOE Patents [OSTI]

    Morgan, Gary L. (Elkridge, MD); Potter, James M. (Los Alamos, NM)

    2001-01-01T23:59:59.000Z

    The apparatus is a gas filled ultraviolet generating lamp for use as a liquid purifier. The lamp is powred by high voltage AC, but has no metallic electrodes within or in contact with the gas enclosure which is constructed as two concentric quartz cylinders sealed together at their ends with the gas fill between the cylinders. Cooling liquid is pumped through the volume inside the inner quartz cylinder where an electrically conductive pipe spaced from the inner cylinder is used to supply the cooling liquid and act as the high voltage electrode. The gas enclosure is enclosed within but spaced from a metal housing which is connected to operate as the ground electrode of the circuit and through which the treated fluid flows. Thus, the electrical circuit is from the central pipe, and through the cooling liquid, the gas enclosure, the treated liquid on the outside of the outer quartz cylinder, and to the housing. The high voltage electrode is electrically isolated from the source of cooling liquid by a length of insulated hose which also supplies the cooling liquid.

  3. Retail Lamps Study 3.2: Lumen and Chromaticity Maintenance of...

    Energy Savers [EERE]

    Maintenance of LED PAR38 Lamps LED T8 Replacement Lamps 2014-05-16 Issuance: Test Procedures for Integrated Light-Emitting Diode Lamps; Supplemental Notice of Proposed Rulemaking...

  4. Observed Minimum Illuminance Threshold for Night Market Vendors in Kenya who use LED Lamps

    E-Print Network [OSTI]

    Johnstone, Peter

    2009-01-01T23:59:59.000Z

    data logger equipped rechargeable LED lamps, monitoring theadoption of the LED lamps, and a follow-up survey.s kiosk illuminated by an LED lamp Radecsky, K. , P.

  5. Fluorescent lamp with static magnetic field generating means

    DOE Patents [OSTI]

    Moskowitz, P.E.; Maya, J.

    1987-09-08T23:59:59.000Z

    A fluorescent lamp wherein magnetic field generating means (e.g., permanent magnets) are utilized to generate a static magnetic field across the respective electrode structures of the lamp such that maximum field strength is located at the electrode's filament. An increase in efficacy during operation has been observed. 2 figs.

  6. Convection venting lensed reflector-type compact fluorescent lamp system

    DOE Patents [OSTI]

    Pelton, B.A.; Siminovitch, M.

    1997-07-29T23:59:59.000Z

    Disclosed herein is a fluorescent lamp housing assembly capable of providing convection cooling to the lamp and the ballast. The lens of the present invention includes two distinct portions, a central portion and an apertured portion. The housing assembly further includes apertures so that air mass is able to freely move up through the assembly and out ventilation apertures. 12 figs.

  7. Convection venting lensed reflector-type compact fluorescent lamp system

    DOE Patents [OSTI]

    Pelton, Bruce A. (825 Manor Rd., El Sobrante, CA 94803); Siminovitch, Michael (829 Manor Rd., El Sobrante, CA 94803)

    1997-01-01T23:59:59.000Z

    Disclosed herein is a fluorescent lamp housing assembly capable of providing convection cooling to the lamp and the ballast. The lens of the present invention includes two distinct portions, a central portion and an apertured portion. The housing assembly further includes apertures so that air mass is able to freely move up through the assembly and out ventilation apertures.

  8. Electrodeless HID lamp study. Final report. [High intensity discharge

    SciTech Connect (OSTI)

    Anderson, J.M.; Johnson, P.D.; Jones, C.E.; Rautenberg, T.H.

    1985-01-01T23:59:59.000Z

    High intensity discharge lamps excited by solenoidal electric fields (SEF/HID) were examined for their ability to give high brightness, high efficacy and good color. Frequency of operation was 13.56 MHz (ISM Band) and power to the lamp plasma ranged from about 400 to 1000 W. Radio frequency transformers with air cores and with air core complemented by ferrite material in the magnetic path were used to provide the voltage for excitation. Electrical properties of the matching network and the lamp plasma were measured or calculated and total light from the lamp was measured by an integrating sphere. Efficacies calculated from measurement were found to agree well with the positive column efficacies of conventional HID lamps containing only mercury, and with additives of sodium, thallium, and scandium iodide. Recommendations for future work are given.

  9. Fixture for supporting and aligning a sample to be analyzed in an x-ray diffraction apparatus

    DOE Patents [OSTI]

    Green, L.A.; Heck, J.L. Jr.

    1985-04-23T23:59:59.000Z

    A fixture is provided for supporting and aligning small samples of material on a goniometer for x-ray diffraction analysis. A sample-containing capillary is accurately positioned for rotation in the x-ray beam by selectively adjusting the fixture to position the capillary relative to the x and y axes thereof to prevent wobble and position the sample along the z axis or the axis of rotation. By employing the subject fixture relatively small samples of materials can be analyzed in an x-ray diffraction apparatus previously limited to the analysis of much larger samples.

  10. Prefab the FabLab : rethinking the habitability of a fabrication lab by including fixture-based components

    E-Print Network [OSTI]

    Nunez, Joseph Gabriel

    2010-01-01T23:59:59.000Z

    This thesis is about defining a fixture-based system that can be adapted into a digital fabrication production system of friction fit assembly. It is inspired by the work and research conducted by the Digital Design ...

  11. Interrogation cradle and insertable containment fixture for detecting birefringent microcrystals in bile

    DOE Patents [OSTI]

    Darrow, Chris; Seger, Tino

    2003-09-30T23:59:59.000Z

    A transparent flow channel fluidly communicates a fluid source and a collection reservoir. An interrogating light beam passes through a first polarizer having a first plane of polarization. The flow channel is orthogonal to the light beam. The light beam passes through a fluid sample as it flows through the flow channel, and is then filtered through a second polarizer having a second plane of polarization rotated 90.degree. from the first plane of polarization. An electronic photo-detector is aligned with the light beam, and signals the presence of birefringent microcrystals in the fluid sample by generating voltage pulses. A disposable containment fixture includes the flow channel and the collection reservoir. The fixture is adapted for removable insertion into an interrogation cradle that includes optical and data processing components. The cradle rigidly positions the centerline of the flow channel orthogonal to the light beam.

  12. Compact fluorescent lamp using horizontal and vertical insulating septums and convective venting geometry

    DOE Patents [OSTI]

    Siminovitch, M.

    1998-02-10T23:59:59.000Z

    A novel design is described for a compact fluorescent lamp, including a lamp geometry which will increase light output and efficacy of the lamp in a base down operating position by providing horizontal and vertical insulating septums positioned in the ballast compartment of the lamp to provide a cooler coldspot. Selective convective venting provides additional cooling of the ballast compartment. 9 figs.

  13. Studies on Temperature Dependence of Rubidium Lamp for Atomic Frequency Standard

    SciTech Connect (OSTI)

    Ghosal, Bikash; Banik, Alak; Vats, Vaibhav; Pal, Sukamal; Bahl, R. K [Space Applications Centre, ISRO, Ahmedabad-380015 (India)

    2011-10-20T23:59:59.000Z

    Rb lamp is a very critical component of the Rb atomic clock's Physics Package. The Rb lamp's performance is very sensitive to temperature and its stability. In this paper we discuss the behaviors of Rb Lamp with temperature. The Rb lamp exciter power and temperature of Rb bulb are very important parameters in controlling the performance of the Rb Lamp. It is observed that at temperatures beyond 110 deg. C, the lamp mode changes from the ring to red mode resulting in abnormal broadening of emission lines and self reversal. The results of our studies on spectral analysis of Rb lamp under various operating conditions are reported in the paper.

  14. DOE Publishes Special CALiPER Report on Retail Lamps

    Broader source: Energy.gov [DOE]

    The U.S. Department of Energy's CALiPER program has released a special report on LED lamps available through the retail marketplace and targeted toward general consumers. The report follows similar...

  15. One piece microwave container screens for electrodeless lamps

    DOE Patents [OSTI]

    Turner, Brian (Myersville, MD); Ury, Michael (Bethesda, MD)

    1998-01-01T23:59:59.000Z

    A microwave powered electrodeless lamp includes an improved screen unit having mesh and solid sections with an internal reflector to reflect light into a light-transmitting chamber defined in the lamp microwave cavity by the reflector and the mesh section. A discharge envelope of a bulb is disposed in the light-transmitting chamber. Light emitted from the envelope is prevented by the reflector from entering the cavity portion bounded by the solid section of the screen. Replacing mesh material by solid metal material as part of the screen unit significantly reduces leakage of microwave energy from the lamp. The solid section has multiple compliant fingers defined therein for engaging the periphery of a flange on the waveguide unit so that a hose clamp can easily secure the screen to the assembly. Screen units of this type having different mesh section configurations can be interchanged in the lamp assembly to produce different respective illumination patterns.

  16. NEWS & VIEWS synchrotron or helium-lamp studies. But

    E-Print Network [OSTI]

    Loss, Daniel

    NEWS & VIEWS synchrotron or helium-lamp studies. But the low energy of the laser photons raises that of a conventional metal. The effects of projection have led to detailed quantitative insights into the properties

  17. U.S. Department of Energy NEPA Categorical Exclusion Determination...

    Broader source: Energy.gov (indexed) [DOE]

    fluorescent lamps or new PL- lamp fixtures, and adding occupancy sensor controls and daylight controls to interior lighting fixtures in some of the facilities; 2) replace tennis...

  18. Magnetic fluorescent lamp having reduced ultraviolet self-absorption

    DOE Patents [OSTI]

    Berman, Samuel M. (San Francisco, CA); Richardson, Robert W. (Pelham, NY)

    1985-01-01T23:59:59.000Z

    The radiant emission of a mercury-argon discharge in a fluorescent lamp assembly (10) is enhanced by providing means (30) for establishing a magnetic field with lines of force along the path of electron flow through the bulb (12) of the lamp assembly, to provide Zeeman splitting of the ultraviolet spectral line. Optimum results are obtained when the magnetic field strength causes a Zeeman splitting of approximately 1.7 times the thermal line width.

  19. Lamp method and apparatus using multiple reflections

    DOE Patents [OSTI]

    MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD)

    2001-01-01T23:59:59.000Z

    An electrodeless microwave discharge lamp includes an envelope with a discharge forming fill disposed therein which emits light, the fill being capable of absorbing light at one wavelength and re-emitting the absorbed light at a different wavelength, the light emitted from the fill having a first spectral power distribution in the absence of reflection of light back into the fill, a source of microwave energy coupled to the fill to excite the fill and cause the fill to emit light, and a reflector disposed within the microwave cavity and configured to reflect at least some of the light emitted by the fill back into the fill while allowing some light to exit, the exiting light having a second spectral power distribution with proportionately more light in the visible region as compared to the first spectral power distribution, wherein the light re-emitted by the fill is shifted in wavelength with respect to the absorbed light and the magnitude of the shift is in relation to an effective optical path length.

  20. Defining the Effectiveness of UV Lamps Installed in Circulating Air Ductwork

    SciTech Connect (OSTI)

    Douglas VanOsdell; Karin Foarde

    2002-11-30T23:59:59.000Z

    Germicidal ultraviolet (UVGI) lamps have a long history of use for inactivating microbial aerosols. Most reports have focused on the control of infectious diseases, such as tuberculosis (TB), in the occupied spaces of medical facilities. Ventilation duct use of UVGI has been increasing. In-duct applications are generally more concerned with controlling environmental organisms than with controlling infections agents. This document reports the results of a project to investigate the ability of UVGI lamps to inactivate representative environmental microbial aerosols in ventilation ducts. During this research, UVGI lamps were experimentally demonstrated to inactivate bioaerosols composed of vegetative bacteria, bacteria spores, or fungal spores to a reproducible degree under conditions of fixed dose. Vegetative bacteria were most susceptible to UVGI, with bacteria and fungal spores being substantially more resistant. The performance equation commonly cited in the literature for UVGI inactivation was found to generally apply, provided its parameters were known. Revision of final report DOE/OR22674/610-40030-01. Revised table 5 on page 33.

  1. Evaluation of Waste Heat Recovery and Utilization from Residential Appliances and Fixtures

    SciTech Connect (OSTI)

    Tomlinson, John J [ORNL; Christian, Jeff [Oak Ridge National Laboratory (ORNL); Gehl, Anthony C [ORNL

    2012-09-01T23:59:59.000Z

    Executive Summary In every home irrespective of its size, location, age, or efficiency, heat in the form of drainwater or dryer exhaust is wasted. Although from a waste stream, this energy has the potential for being captured, possibly stored, and then reused for preheating hot water or air thereby saving operating costs to the homeowner. In applications such as a shower and possibly a dryer, waste heat is produced at the same time as energy is used, so that a heat exchanger to capture the waste energy and return it to the supply is all that is needed. In other applications such as capturing the energy in drainwater from a tub, dishwasher, or washing machine, the availability of waste heat might not coincide with an immediate use for energy, and consequently a heat exchanger system with heat storage capacity (i.e. a regenerator) would be necessary. This study describes a two-house experimental evaluation of a system designed to capture waste heat from the shower, dishwasher clothes washer and dryer, and to use this waste heat to offset some of the hot water energy needs of the house. Although each house was unoccupied, they were fitted with equipment that would completely simulate the heat loads and behavior of human occupants including operating the appliances and fixtures on a demand schedule identical to Building American protocol (Hendron, 2009). The heat recovery system combined (1) a gravity-film heat exchanger (GFX) installed in a vertical section of drainline, (2) a heat exchanger for capturing dryer exhaust heat, (3) a preheat tank for storing the captured heat, and (4) a small recirculation pump and controls, so that the system could be operated anytime that waste heat from the shower, dishwasher, clothes washer and dryer, and in any combination was produced. The study found capturing energy from the dishwasher and clothes washer to be a challenge since those two appliances dump waste water over a short time interval. Controls based on the status of the dump valve on these two appliances would have eliminated uncertainty in knowing when waste water was flowing and the recovery system operated. The study also suggested that capture of dryer exhaust heat to heat incoming air to the dryer should be examined as an alternative to using drying exhaust energy for water heating. The study found that over a 6-week test period, the system in each house was able to recover on average approximately 3000 W-h of waste heat daily from these appliance and showers with slightly less on simulated weekdays and slightly more on simulated weekends which were heavy wash/dry days. Most of these energy savings were due to the shower/GFX operation, and the least savings were for the dishwasher/GFX operation. Overall, the value of the 3000 W-h of displaced energy would have been $0.27/day based on an electricity price of $.09/kWh. Although small for today s convention house, these savings are significant for a home designed to approach maximum affordable efficiency where daily operating costs for the whole house are less than a dollar per day. In 2010 the actual measured cost of energy in one of the simulated occupancy houses which waste heat recovery testing was undertaken was $0.77/day.

  2. Red phosphors for use in high CRI fluorescent lamps

    DOE Patents [OSTI]

    Srivastava, Alok; Comanzo, Holly; Manivannan, Vankatesan; Setlur, Anant Achyut

    2005-11-15T23:59:59.000Z

    Novel red emitting phosphors for use in fluorescent lamps resulting in superior color rendering index values compared to conventional red phosphors. Also disclosed is a fluorescent lamp including a phosphor layer comprising blends of one or more of a blue phosphor, a blue-green phosphor, a green phosphor and a red a phosphor selected from the group consisting of SrY.sub.2 O.sub.4 :Eu.sup.3+, (Y,Gd)Al.sub.3 B.sub.4 O.sub.12 :Eu.sup.3+, and [(Y.sub.1-x-y-m La.sub.y)Gd.sub.x ]BO.sub.3 :Eu.sub.m wherein y<0.50 and m=0.001-0.3. The phosphor layer can optionally include an additional deep red phosphor and a yellow emitting phosphor. The resulting lamp will exhibit a white light having a color rendering index of 90 or higher with a correlated color temperature of from 2500 to 10000 Kelvin. The use of the disclosed red phosphors in phosphor blends of lamps results in high CRI light sources with increased stability and acceptable lumen maintenance over the course of the lamp life.

  3. VENTURERS CC FIXTURES 2013 Sun 21/4 Kilmington away 2:00

    E-Print Network [OSTI]

    Burton, Geoffrey R.

    VENTURERS CC FIXTURES 2013 Sun 21/4 Kilmington away 2:00 Sun 28/4 Bathford home 2:00 Tue 30/4 Novia home 6:00 Wed 1/5 Monkton Combe away 6:00 Wed 8/5 Atworth away 6:00 Thu 9/5 Royal Oak away 6:00 Sun 12/5 Priston away 2:30 Wed 15/5 Kingswood away 6:00 Sun 19/5 Bristol Venturers home 2:00 Thu 23/5 Bradford 39

  4. Kinematic couplings: A review of design principles and applications

    E-Print Network [OSTI]

    Slocum, Alexander H.

    From the humble three-legged milking stool to a SEMI standard wafer pod location to numerous sub-micron fixturing applications in instruments and machines, exactly constrained mechanisms provide precision, robustness, and ...

  5. Microwave generated electrodeless lamp for producing bright output

    SciTech Connect (OSTI)

    Wood, Ch. H.; Ury, M. G.

    1985-03-26T23:59:59.000Z

    A microwave generated electrodeless light source for producing a bright output comprising a lamp structure including a microwave chamber and a plasma medium-containing lamp envelope having a maximum dimension which is substantially less than a wavelength disposed therein. To provide the desired radiation output the interior of the chamber is coated with a UV-reflective material and the chamber has an opening for allowing UV radiation to exit, which is covered with a metallic mesh. The chamber is arranged to be near-resonant at a single wavelength, and the lamp envelope has a fill including mercury at an operating pressure of 1-2 atmospheres, while a power density of at least 250-300 (watts/cm/sup 3/) is coupled to the envelope to result in a relatively high deep UV output at a relatively high brightness.

  6. Very high efficacy electrodeless high intensity discharge lamps

    SciTech Connect (OSTI)

    Johnson, P.D.

    1987-11-10T23:59:59.000Z

    This patent describes an electrodeless arc lamp for forming a ring shaped plasma in a region therein during operation comprising a tube having a raised bottom center section, and an optically transparent outer jacket hermetically sealing the tube to protect the tube from cooling by convection. The raised center section rises centrally to form a ring shaped reservoir below the region in which the rig shaped plasma is formed to minimize wall cooling during operation of the lamp so that there is enhanced excitation near the center of the tube.

  7. Practical features of illumination with high pressure sodium lamps

    SciTech Connect (OSTI)

    Corth, R.

    1983-06-01T23:59:59.000Z

    A number of concerns raised about the health effects of high pressure sodium lamps (HPS) are discussed. The notion of a ''natural'' human photic environment based on sunlight is disputed. Humans are better adapted to the ''greenish'' spectral composition of forest light than to direct sunlight. It is ironic that the artificial light source which has received the most disapproval, cool white flourescent lamp, has a spectral composition similar to that of forest light. HPS is also available in a full range of colors. Some successful examples of HPS--from North Division High School, in Milwaukee, Wisconsin, to museum exhibits at National Geographic in Washington--are listed.

  8. Very high efficacy electrodeless high intensity discharge lamps

    DOE Patents [OSTI]

    Johnson, Peter D. (Schenectady, NY)

    1987-01-01T23:59:59.000Z

    An electrodeless arc lamp comprises an outer jacket hermetically sealing and thermally protecting an arc tube inside which has an upwardly convex bottom center section. The absence of chemically reactive electrode material makes it possible to use metal halides other than iodides. The tube contains chlorides, bromides or a mixture thereof of scandium and sodium in a nearly equimolar relationship in addition to mercury and an inert gas. Good color balance can be obtained at reduced reservoir temperature and with less power loss. Reduction in wall temperature makes it possible to attain longer lamp life.

  9. Very high efficacy electrodeless high intensity discharge lamps

    DOE Patents [OSTI]

    Johnson, P.D.

    1985-10-03T23:59:59.000Z

    An electrodeless arc lamp comprises an outer jacket hermetically sealing and thermally protecting an arc tube inside which has an upwardly convex bottom center section. The absence of chemically reactive electrode material makes it possible to use metal halides other than iodides. The tube contains chlorides, bromides or a mixture thereof of scandium and sodium in a nearly equimolar relationship in addition to mercury and an inert gas. Good color balance can be obtained at reduced reservoir temperature and with less power loss. Reduction in wall temperature makes it possible to attain longer lamp life.

  10. LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR®

    Broader source: Energy.gov [DOE]

    This May 19, 2009 webcast summarized CALiPER's recent benchmark testing of common omnidirectional incandescent lamps (e.g., A-lamps), and provided an update on ENERGY STAR criteria for LED integral...

  11. April 2002, L. Henn-Lecordier LAMP general operating procedures 1 Laboratory for Advanced Materials Processing

    E-Print Network [OSTI]

    Rubloff, Gary W.

    written request ­ Receive safety training from DES ­ Lab orientation with the lab manager ­ Equipment training and qualification #12;April 2002, L. Henn-Lecordier LAMP general operating procedures 9 LAMP "10

  12. A Behavioral SPICE Compatible Model of an Electrodeless Fluorescent Lamp Sam Ben-Yaakov*1

    E-Print Network [OSTI]

    to the plasma. In the case of the lamp with electrodes, coupling is via wires. In the case of the electrodelessA Behavioral SPICE Compatible Model of an Electrodeless Fluorescent Lamp Sam Ben-Yaakov*1 , Moshe, SPICE compatible, model was developed for an electrodeless fluorescent lamp (OSRAM SYLVANIA ICETRON

  13. Issues, Models and Solutions for Triac Modulated Phase Dimming of LED Lamps

    E-Print Network [OSTI]

    Lehman, Brad

    Issues, Models and Solutions for Triac Modulated Phase Dimming of LED Lamps Dustin Rand (Raytheon Edison socket LED lamps directly from residential phase modulated dimmer switches. In order to explain brightness "White Light" LEDs have experts predicting that the "bright white replacement lamp" could trigger

  14. Basics of lava-lamp convection Balzs Gyre1

    E-Print Network [OSTI]

    Jánosi, Imre M.

    marketed only since the sixties 1 . The most essential ingredients are two immis- cible fluids of densities function, the lava lamp has been used also as visual aid in geoscience courses 2 demonstrat- ing phenomena such as the transformation of energy, force and motion, adiabatic circulations in the atmosphere and oceans, or magma

  15. Mercury Lamps Recycling Fluorescent light-tubes, compact fluorescent bulbs, mercury and sodium vapor lamps, ultraviolet and

    E-Print Network [OSTI]

    Baker, Chris I.

    Mercury Lamps Recycling Fluorescent light-tubes, compact fluorescent bulbs, mercury and sodium labeled for shipment to a recycling plant for mercury, glass and aluminum recovery. The beneficial re can be recycled infinitely without losing its purity or strength. While the primary end product

  16. All mercury lamps contain small amounts of mercury. An electric current passes through the lamp and vaporizes the mercury to generate light. Recycling mercury containing lamps protects human health and our environment from heavy

    E-Print Network [OSTI]

    George, Steven C.

    and vaporizes the mercury to generate light. Recycling mercury containing lamps protects human health and our the environment by recycling universal wastes, contact EH&S at (949) 824-6200 or visit: www.ehs.uci.edu Mercury lamp recycling separates a number of materials for further use in new products. · The mercury is reused

  17. ISSUANCE 2014-12-29: Energy Conservation Program: Clarification for Energy Conservation Standards and Test Procedures for Fluorescent Lamp Ballasts

    Broader source: Energy.gov [DOE]

    Energy Conservation Program: Clarification for Energy Conservation Standards and Test Procedures for Fluorescent Lamp Ballasts

  18. 2014-04-11 Issuance: Energy Conservation Standards for General Service Fluorescent Lamps and Incandescent Reflector Lamps; Notice of Proposed Rulemaking

    Broader source: Energy.gov [DOE]

    This document is a pre-publication Federal Register notice of proposed rulemaking regarding energy conservation standards for general service fluorescent lamps and incandescent reflectors lamps, as issued by the Assistant Secretary for Energy Efficiency and Renewable Energy on April 11, 2014.

  19. CALiPER Retail Lamps Study RRL3.2 Lumen and Chromaticity Maintenance of LED A lamps Operated in Steady-State Conditions

    SciTech Connect (OSTI)

    Royer, Michael P.; McCullough, Jeffrey J.; Tucker, Joseph C.

    2014-12-01T23:59:59.000Z

    The lumen depreciation and color shift of 17 different A lamps (15 LED, 1 CFL, 1 halogen) was monitored in the automated long-term test apparatus (ALTA) for more than 7,500 hours. Ten samples of each lamp model were tested, with measurements recorded on a weekly basis. The lamps were operated continuously at an ambient temperature of 45°C (-1°C). Importantly, the steady-state test conditions were not optimized for inducing catastrophic failure for any of the lamp technologies—to which thermal cycling is a strong contributor— and are not typical of normal use patterns—which usually include off periods where the lamp cools down. Further, the test conditions differ from those used in standardized long-term test methods (i.e., IES LM-80, IES LM-84), so the results should not be directly compared. On the other hand, the test conditions are similar to those used by ENERGY STAR (when elevated temperature testing is called for). Likewise, the conditions and assumptions used by manufacturers to generated lifetime claims may vary; the CALiPER long-term data is informative, but cannot necessarily be used to discredit manufacturer claims. The test method used for this investigation should be interpreted as one more focused on the long-term effects of elevated temperature operation, at an ambient temperature that is not uncommon in luminaires. On average, the lumen maintenance of the LED lamps monitored in the ALTA was better than benchmark lamps, but there was considerable variation from lamp model to lamp model. While three lamp models had average lumen maintenance above 99% at the end of the study period, two products had average lumen maintenance below 65%, constituting a parametric failure. These two products, along with a third, also exhibited substantial color shift, another form of parametric failure. While none of the LED lamps exhibited catastrophic failure—and all of the benchmarks did—the early degradation of performance is concerning, especially with a new technology trying to build a reputation with consumers. Beyond the observed parametric failures nearly half of the products failed to meet early-life thresholds for lumen maintenance, which were borrowed from ENERGY STAR specifications. That is, the lumen maintenance was sufficiently low at 6,000 hours that seven of the products are unlikely to have lumen maintenance above 70% at their rated lifetime (which was usually 25,000 hours). Given the methods used for this investigation—most notably continuous operation—the results should not be interpreted as indicative of a lamp’s performance in a typical environment. Likewise, these results are not directly relatable to manufacturer lifetime claims. This report is best used to understand the variation in LED product performance, compare the robustness of LED lamps and benchmark conventional lamps, and understand the characteristics of lumen and chromaticity change. A key takeaway is that the long-term performance of LED lamps can vary greatly from model to model (i.e., the technology is not homogenous), although the lamp-to-lamp consistency within a given model is relatively good. Further, operation of LED lamps in an enclosed luminaire (or otherwise in high ambient temperatures), can induce parametric failure of LEDs much earlier than their rated lifetime; manufacturer warnings about such conditions should be followed if performance degradation is unacceptable.

  20. Replacement of Lighting Fixtures with LED Energy Efficient Lights at the Parking Facility, Milwaukee, Wisconsin

    SciTech Connect (OSTI)

    David Brien

    2012-06-21T23:59:59.000Z

    The Forest County Potawatomi Community (FCPC or Tribe) owns a six-story parking facility adjacent to its Potawatomi Bingo Casino (the Casino) in Milwaukee, Wisconsin, as well as a valet parking facility under the Casino (collectively, the Parking Facility). The Parking Facility contained 205-watt metal halide-type lights that, for security reasons, operated 24 hours per day, 7 days per week. Starting on August 30, 2010, the Tribe replaced these fixtures with 1,760 state-of-the-art, energy efficient 55-Watt LED lights. This project resulted in an immediate average reduction in monthly peak demand of 238 kW over the fourth quarter of 2010. The average reduction in monthly peak demand from October 1 through December 31, 2010 translates into a forecast annual electrical energy reduction of approximately 1,995,000 kWh or 47.3% of the pre-project demand. This project was technically effective, economically feasible, and beneficial to the public not only in terms of long term energy efficiency and associated emissions reductions, but also in the short-term jobs provided for the S.E. Wisconsin region. The project was implemented, from approval by U.S. Department of Energy (DOE) to completion, in less than 6 months. The project utilized off-the-shelf proven technologies that were fabricated locally and installed by local trade contractors.

  1. Potential Operation and Maintenance (O&M) Savings at the Dunbar Middle and Sims Elementary Schools

    E-Print Network [OSTI]

    Liu, M.; Houcek, J. K.; Claridge, D. E.; Haberl, J. S.

    1993-01-01T23:59:59.000Z

    ), 22 250-watt lamps (Type G), and 10 100-watt lamps (Type H). The lighting fixtures have a total installed wattage of 72,368. The lighting fixture counts are summarized in Table C-l. Texas Governor's Energy Office LoanSTAR O&M Program Energy System...-watt fixtures (Type D, 1x4,2-lamp), one 66-watt fixture (Type E, 2-lamp, 3 feet strip), 106 88-watt fixtures..(Type F), 12 150- watt lamps (Type G), and 32 150-watt fixture s(Type H, 2x4,4-lamp). The lighting fixtures have a total wattage of 99.5 k...

  2. Comparison of different light lamps for collecting diptera associated with livestock concentration areas

    E-Print Network [OSTI]

    Neeb, Charles W

    1971-01-01T23:59:59.000Z

    . , Texas Tech (Jniversity Directed by: Mr. M. A. Price The attractiveness of radrant energy emitted by blacklight (BL), blacklight-blue (BLH), strontium ? blue and argon ultraviolet lamps was compared in standard- survey omnidirectional light traps... with livestock concentration areas. Pecos County. Lrgon study area. 1967. . . . . . . . . . . 6B Field comparison of light wavelengths emitted from BL fluorescent lamp with light wavelengths emitted from BLB, strontium and argon lamps on attractiveness...

  3. Lumen and Chromaticity Maintenance of LED PAR38 Lamps Operated in Steady-State Conditions

    SciTech Connect (OSTI)

    Royer, Michael P.

    2014-12-01T23:59:59.000Z

    The lumen depreciation and color shift of 38 different lamps (32 LED, 2 CFL, 1 ceramic metal halide [CMH], 3 halogen) were monitored in a specially developed automated long-term test apparatus (ALTA2) for nearly 14,000 hours. Five samples of each lamp model were tested, with measurements recorded on a weekly basis. The lamps were operated continuously at a target ambient temperature between 44°C and 45°C.

  4. Low pressure arc discharge lamp apparatus with magnetic field generating means

    DOE Patents [OSTI]

    Grossman, M.W.; George, W.A.; Maya, J.

    1987-10-06T23:59:59.000Z

    A low-pressure arc discharge apparatus having a magnetic field generating means for increasing the output of a discharge lamp is disclosed. The magnetic field generating means, which in one embodiment includes a plurality of permanent magnets, is disposed along the lamp for applying a constant transverse magnetic field over at least a portion of the positive discharge column produced in the arc discharge lamp operating at an ambient temperature greater than about 25 C. 3 figs.

  5. EA-1881: Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts

    Broader source: Energy.gov [DOE]

    This EA evaluates the environmental impacts of a proposal to amend energy conservation standards for various consumer products and certain commercial and industrial equipment, including fluorescent lamp ballasts.

  6. Text-Alternative Version: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR®

    Broader source: Energy.gov [DOE]

    Below is the text-alternative version of the LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® webcast.

  7. LED Linear Lamps and Troffer Lighting: CALiPER Report Series 21

    ScienceCinema (OSTI)

    Beeson, Tracy; Miller, Naomi

    2014-06-23T23:59:59.000Z

    Video about CALiPER Report Series 21 on LED Linear Lamps and Troffer Lighting, featuring interviews with Tracy Beeson and Naomi Miller of Pacific Northwest National Laboratory.

  8. Demonstration of LED Retrofit Lamps at the Smithsonian American Art Museum, Washington, DC

    SciTech Connect (OSTI)

    Miller, Naomi J.; Rosenfeld, Scott M.

    2012-06-22T23:59:59.000Z

    This report documents observations and results obtained from a lighting demonstration project conducted under the U.S. Department of Energy GATEWAY Solid-State Lighting (SSL) Technology Demonstration Program at the Smithsonain American Art Museum in Washington, DC. LED Lamp samples were tested in the museum workshop, temporarily installed in a gallery for feedback, and ultimately replaced all traditional incandescent lamps in one gallery of modernist art at the American Art Museum and partially replacing lamps in two galleries at the Musesum's Renwick Gallery. This report describes the selection and testing process, technology challenges, perceptions, economics, energy use, and mixed results of usign LED replacement lamps in art galleries housing national treasures.

  9. The Electrodeless Discharge Lamps Coated with the Titania Thin Film for Photocatalysis in a Microwave Field

    E-Print Network [OSTI]

    Cirkva, Vladimir

    The Electrodeless Discharge Lamps Coated with the Titania Thin Film for Photocatalysis assisted photocatalysis using TiO2 thin films has been examined. Several factors influencing

  10. Conservation potential of compact fluorescent lamps in India and Brazil

    SciTech Connect (OSTI)

    Gadgil, A.; Martino Jannuzzi, G. de (Lawrence Berkeley Lab., CA (USA); Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia)

    1989-07-01T23:59:59.000Z

    We evaluate the conservation potential of compact fluorescent lamps (CFLs) for managing the rapidly increasing electrical energy and peak demand in India and Brazil. Using very conservative assumptions, we find that the cost of conserved energy using 16 W CFLs is 4 and 6 times less than the long range marginal cost of electricity for the two countries. The cost of avoided peak installed capacity is 6 and 9.5 times less than the cost of new installed capacity for India and Brazil. The analysis is undertaken from the three separate perspectives of the national economies, the consumers, and the utilities. We find that because residential electricity is subsidized, the consumers have little or no incentive to purchase and install the CFLs, unless they too are subsidized. However, the benefits of CFL installation to the utility are so large that subsidizing them is a paying proposition for the utility are so large that subsidizing them is a paying proposition for the utility in almost all cases. As an illustration of a gradual introduction strategy for CFLs, we calculate a scenario where national savings of the order of US $1.2 million per day for India and US $2.5 million per day for Brazil are reached in 10 years by a small and gradual transfer of subsidy from residential electricity to CFLs. We then explore the barriers to immediate large scale introduction of these lamps in the two countries. Specific technical and marketing problems are identified and discussed, which would require solution before such an introduction can be attempted. Lastly, we discuss the range of policy instruments, in addition to a subsidy scheme, that can be used for promoting the diffusion of these lamps in the domestic and commercial sector. 47 refs., 15 figs., 2 tabs.

  11. Microwave lamp with multi-purpose rotary motor

    DOE Patents [OSTI]

    Ury, Michael G. (Bethesda, MD); Turner, Brian (Myersville, MD); Wooten, Robert D. (Rockville, MD)

    1999-01-01T23:59:59.000Z

    In a microwave powered electrodeless lamp, a single rotary motor is used to a) rotate the bulb and b) provide rotary motion to a blower or pump means for providing cooling fluid to the magnetron and/or to a forced gas cooling for providing cooler gas to the bulb. The blower may consist of only of an impeller without the usual blower housing. The motor, bulb stem and bulb, or motor, bulb stem, bulb and blower may be formed as an integral unit so as to facilitate replacement.

  12. Microwave lamp with multi-purpose rotary motor

    DOE Patents [OSTI]

    Ury, M.G.; Turner, B.; Wooten, R.D.

    1999-02-02T23:59:59.000Z

    In a microwave powered electrodeless lamp, a single rotary motor is used to (a) rotate the bulb and (b) provide rotary motion to a blower or pump means for providing cooling fluid to the magnetron and/or to a forced gas cooler for providing cooling gas to the bulb. The blower may consist of only of an impeller without the usual blower housing. The motor, bulb stem and bulb, or motor, bulb stem, bulb and blower may be formed as an integral unit so as to facilitate replacement. 8 figs.

  13. High Efficiency LED Lamp for Solid-State Lighting

    SciTech Connect (OSTI)

    James Ibbetson

    2006-12-31T23:59:59.000Z

    This report contains a summary of technical achievements during a three-year project to demonstrate high efficiency, solid-state lamps based on gallium nitride/silicon carbide light-emitting diodes. Novel chip designs and fabrication processes are described for a new type of nitride light-emitting diode with the potential for very high efficiency. This work resulted in the demonstration of blue light-emitting diodes in the one watt class that achieved up to 495 mW of light output at 350 mA drive current, corresponding to quantum and wall plug efficiencies of 51% and 45%, respectively. When combined with a phosphor in Cree's 7090 XLamp package, these advanced blue-emitting devices resulted in white light-emitting diodes whose efficacy exceeded 85 lumens per watt. In addition, up to 1040 lumens at greater than 85 lumens per watt was achieved by combining multiple devices to make a compact white lamp module with high optical efficiency.

  14. LED Lamp Project Lights the Way to Flicker-Free Replacement Jade Sky Technologies and UC Davis's California Lighting Technology Center demonstrate the

    E-Print Network [OSTI]

    California at Davis, University of

    LED Lamp Project Lights the Way to Flicker-Free Replacement Jade Sky the flicker and dimming requirements set by the Voluntary California Quality LED Lamp for incentivized LED replacement lamps. These criteria go beyond energy efficiency

  15. The evolving price of household LED lamps: Recent trends and historical comparisons for the US market

    SciTech Connect (OSTI)

    Gerke, Brian F.; Ngo, Allison T.; Alstone, Andrea L.; Fisseha, Kibret S.

    2014-10-14T23:59:59.000Z

    In recent years, household LED light bulbs (LED A lamps) have undergone a dramatic price decline. Since late 2011, we have been collecting data, on a weekly basis, for retail offerings of LED A lamps on the Internet. The resulting data set allows us to track the recent price decline in detail. LED A lamp prices declined roughly exponentially with time in 2011-2014, with decline rates of 28percent to 44percent per year depending on lumen output, and with higher-lumen lamps exhibiting more rapid price declines. By combining the Internet price data with publicly available lamp shipments indices for the US market, it is also possible to correlate LED A lamp prices against cumulative production, yielding an experience curve for LED A lamps. In 2012-2013, LED A lamp prices declined by 20-25percent for each doubling in cumulative shipments. Similar analysis of historical data for other lighting technologies reveals that LED prices have fallen significantly more rapidly with cumulative production than did their technological predecessors, which exhibited a historical decline of 14-15percent per doubling of production.

  16. CALiPER Report 20.3: Robustness of LED PAR38 Lamps

    SciTech Connect (OSTI)

    Poplawski, Michael E.; Royer, Michael P.; Brown, Charles C.

    2014-12-31T23:59:59.000Z

    Three samples of 40 of the Series 20 PAR38 lamps underwent multi-stress testing, whereby samples were subjected to increasing levels of simultaneous thermal, humidity, electrical, and vibrational stress. The results do not explicitly predict expected lifetime or reliability, but they can be compared with one another, as well as with benchmark conventional products, to assess the relative robustness of the product designs. On average, the 32 LED lamp models tested were substantially more robust than the conventional benchmark lamps. As with other performance attributes, however, there was great variability in the robustness and design maturity of the LED lamps. Several LED lamp samples failed within the first one or two levels of the ten-level stress plan, while all three samples of some lamp models completed all ten levels. One potential area of improvement is design maturity, given that more than 25% of the lamp models demonstrated a difference in failure level for the three samples that was greater than or equal to the maximum for the benchmarks. At the same time, the fact that nearly 75% of the lamp models exhibited better design maturity than the benchmarks is noteworthy, given the relative stage of development for the technology.

  17. Low Frequency Architecture for Multi-Lamp CCFL Systemswith Capacitive Ignition

    E-Print Network [OSTI]

    Low Frequency Architecture for Multi-Lamp CCFL Systemswith Capacitive Ignition Monm Doshi (I-0425 regan.zane@colorado.edu Absfruci-This paper presents a low frequency architecture for driving parallel to the architecture is a proposed capacitive coupling approach for ac lamp ignition. The system consists of a single

  18. A light diet for a giant appetite: An assessment of China's proposed fluorescent lamp standard

    SciTech Connect (OSTI)

    Lin, Jiang

    2002-04-11T23:59:59.000Z

    Lighting has been one of the fastest growing electric end-uses in China over the last twenty years, with an average annual growth rate of 14%. Fluorescent lighting provides a significant portion of China's lighting need. In 1998, China produced 680 million fluorescent lamps, of which 420 million were linear fluorescent lamps of various diameters (T8 to T12). There are substantial variations both in energy efficiency and lighting performance among locally produced fluorescent lamps. Such variations present a perfect opportunity for policy intervention through efficiency standards to promote the adoption of more efficient fluorescent lamps in China. This paper analyzes China's proposed minimum efficiency standard for fluorescent lamps and presents an assessment of its likely impacts on China's lighting energy consumption and GHG emissions.

  19. Energy Conservation Program: Data Collection and Comparison with Forecasted Unit Sales for Five Lamp Types, Notice of Data Availability

    Broader source: Energy.gov [DOE]

    Energy Conservation Program: Data Collection and Comparison with Forecasted Unit Sales for Five Lamp Types, Notice of Data Availability

  20. CALiPER Report 21.3: Cost-Effectiveness of Linear (T8) LED Lamps

    SciTech Connect (OSTI)

    Miller, Naomi J.; Perrin, Tess E.; Royer, Michael P.

    2014-05-27T23:59:59.000Z

    Meeting performance expectations is important for driving adoption of linear LED lamps, but cost-effectiveness may be an overriding factor in many cases. Linear LED lamps cost more initially than fluorescent lamps, but energy and maintenance savings may mean that the life-cycle cost is lower. This report details a series of life-cycle cost simulations that compared a two-lamp troffer using LED lamps (38 W total power draw) or fluorescent lamps (51 W total power draw) over a 10-year study period. Variables included LED system cost ($40, $80, or $120), annual operating hours (2,000 hours or 4,000 hours), LED installation time (15 minutes or 30 minutes), and melded electricity rate ($0.06/kWh, $0.12/kWh, $0.18/kWh, or $0.24/kWh). A full factorial of simulations allows users to interpolate between these values to aid in making rough estimates of economic feasibility for their own projects. In general, while their initial cost premium remains high, linear LED lamps are more likely to be cost-effective when electric utility rates are higher than average and hours of operation are long, and if their installation time is shorter.

  1. Recovery of yttrium from cathode ray tubes and lamps’ fluorescent powders: experimental results and economic simulation

    SciTech Connect (OSTI)

    Innocenzi, V., E-mail: valentina.innocenzi1@univaq.it; De Michelis, I.; Ferella, F.; Vegliò, F.

    2013-11-15T23:59:59.000Z

    Highlights: • Fluorescent powder of lamps. • Fluorescent powder of cathode ray rubes. • Recovery of yttrium from fluorescent powders. • Economic simulation for the processes to recover yttrium from WEEE. - Abstract: In this paper, yttrium recovery from fluorescent powder of lamps and cathode ray tubes (CRTs) is described. The process for treating these materials includes the following: (a) acid leaching, (b) purification of the leach liquors using sodium hydroxide and sodium sulfide, (c) precipitation of yttrium using oxalic acid, and (d) calcinations of oxalates for production of yttrium oxides. Experimental results have shown that process conditions necessary to purify the solutions and recover yttrium strongly depend on composition of the leach liquor, in other words, whether the powder comes from treatment of CRTs or lamp. In the optimal experimental conditions, the recoveries of yttrium oxide are about 95%, 55%, and 65% for CRT, lamps, and CRT/lamp mixture (called MIX) powders, respectively. The lower yields obtained during treatments of MIX and lamp powders are probably due to the co-precipitation of yttrium together with other metals contained in the lamps powder only. Yttrium loss can be reduced to minimum changing the experimental conditions with respect to the case of the CRT process. In any case, the purity of final products from CRT, lamps, and MIX is greater than 95%. Moreover, the possibility to treat simultaneously both CRT and lamp powders is very important and interesting from an industrial point of view since it could be possible to run a single plant treating fluorescent powder coming from two different electronic wastes.

  2. ISSUANCE 2015-01-26: Energy Conservation Program: Energy Conservation Standards for High-Intensity Lamps, Notice to Reopen Comment Period

    Broader source: Energy.gov [DOE]

    Energy Conservation Program: Energy Conservation Standards for High-Intensity Lamps, Notice to Reopen Comment Period

  3. Energy savings with solid-state ballasted high-pressure sodium lamps

    SciTech Connect (OSTI)

    Verderber, R.R.; Morse, O.

    1981-04-01T23:59:59.000Z

    The performance of three types of solid-state ballasts used to operate high-pressure sodium lamps is discussed. Each type of solid-state ballast has been designed to operate an HPS lamp of a different wattage (150, 200, and 400 watts). The performance of these ballasts compared to standard core-coil ballasts operating the same HPS lamps shows that system efficiency improves as much as 17%. The solid-state ballasted HPS system also demonstrates excellent regulation with respect to input voltage and output power. These new ballasts can dim the HPS lamps and reduce flicker from more than 60% to less than 3%. Refitting street lighting with these new HPS systims provides an attractive return on initial capital investment.

  4. LED Linear Lamps and Troffer Lighting: CALiPER Report Series 21

    Broader source: Energy.gov [DOE]

    View the video about CALiPER Report Series 21 on LED Linear Lamps and Troffer Lighting, featuring interviews with Tracy Beeson and Naomi Miller of Pacific Northwest National Laboratory.

  5. Text-Alternative Version: CALiPER Report Series 20 on LED PAR38 Lamps

    Broader source: Energy.gov [DOE]

    Michael Royer, Lighting Engineer, Pacific Northwest National Laboratory: The CALiPER program looks at typical LED lamp performance attributes. As we've gone through the progression of reports, we...

  6. DOE Publishes CALiPER Snapshot Report on LED MR16 Lamps

    Broader source: Energy.gov [DOE]

    The U.S. Department of Energy's CALiPER program has released a Snapshot Report on MR16 lamps, which utilizes the LED Lighting Facts® program's extensive product database to help industry...

  7. Integrated starting and running amalgam assembly for an electrodeless fluorescent lamp

    DOE Patents [OSTI]

    Borowiec, Joseph Christopher (Schenectady, NY); Cocoma, John Paul (Clifton Park, NY); Roberts, Victor David (Burnt Hills, NY)

    1998-01-01T23:59:59.000Z

    An integrated starting and running amalgam assembly for an electrodeless SEF fluorescent lamp includes a wire mesh amalgam support constructed to jointly optimize positions of a starting amalgam and a running amalgam in the lamp, thereby optimizing mercury vapor pressure in the lamp during both starting and steady-state operation in order to rapidly achieve and maintain high light output. The wire mesh amalgam support is constructed to support the starting amalgam toward one end thereof and the running amalgam toward the other end thereof, and the wire mesh is rolled for friction-fitting within the exhaust tube of the lamp. The positions of the starting and running amalgams on the wire mesh are jointly optimized such that high light output is achieved quickly and maintained, while avoiding any significant reduction in light output between starting and running operation.

  8. Demonstration of LED Retrofit Lamps at the Jordan Schnitzer Museum of Art

    SciTech Connect (OSTI)

    Miller, Naomi J.

    2011-09-01T23:59:59.000Z

    The Jordan Schnitzer Museum of Art in Eugene, Oregon, houses a remarkable permanent collection of Asian art and antiquities, modern art, and sculpture, and also hosts traveling exhibitions. In the winter and spring of 2011, a series of digital photographs by artist Chris Jordan, titled "Running the Numbers," was exhibited in the Coeta and Donald Barker Special Exhibitions Gallery. These works graphically illustrate waste (energy, money, health, consumer objects, etc.) in contemporary culture. The Bonneville Power Administration and the Eugene Water and Electricity Board provided a set of Cree 12W light-emitting diode (LED) PAR38 replacement lamps (Cree LRP38) for the museum to test for accent lighting in lieu of their standard Sylvania 90W PAR38 130V Narrow Flood lamps (which draw 78.9W at 120V). At the same time, the museum tested LED replacement lamps from three other manufacturers, and chose the Cree lamp as the most versatile and most appropriate color product for this exhibit. The lamps were installed for the opening of the show in January 2011. This report describes the process for the demonstration, the energy and economic results, and results of a survey of the museum staff and gallery visitors on four similar clusters of art lighted separately by four PAR38 lamps.

  9. Assessing the Risk of Mercury in Drinking Water after UV Lamp Breaks Page 1 Assessing the Risk of Mercury in Drinking Water after UV Lamp Breaks

    E-Print Network [OSTI]

    energy through temperature and pressure to drive the mercury into a vapor phase. Mercury is a heavy metal, and is regulated in drinking water by the EPA through the Safe Drinking Water Act (SDWA). If an on-line lamp break historically the U.S. has been skeptical to implement UV into drinking water systems, many areas of Europe

  10. Reducing home lighting expenses

    SciTech Connect (OSTI)

    Aimone, M.A.

    1981-02-01T23:59:59.000Z

    Ways to reduce lighting expenses are summarized. These include: turning off lights when not in use; keeping fixtures and lamps clean; replacing lamps with more efficient types; using three-way bulbs; use of daylighting; buying fewer lamps and reducing lamp wattage; consider repainting rooms; replacing recessed fixtures with tracklighting; and using efficient lamps for outdoor use. (MCW)

  11. CX-008415: Categorical Exclusion Determination | Department of...

    Broader source: Energy.gov (indexed) [DOE]

    fluorescent lamps or new PL-lamp fixtures, and adding occupancy sensor controls and daylight controls to interior lighting fixtures in some of the facilities. U.S. Department of...

  12. The glass lamps from the 11th-century shipwreck at Serc?e Liman, Turkey: a thesis

    E-Print Network [OSTI]

    Morden, Margaret Elizabeth

    1982-01-01T23:59:59.000Z

    writ1ng during the 4th century, describes a hanging lamp in the following terms: "From the center of panelled ceil1ngs 1n spac1ous rooms . . . openwork bronze lamps were suspended by cable . like a kind of tree w1th pliant vine-like branches... to the three major forms of lamp development discussed earlier. Paul the S1lentiary, in h1s description of Sancta Soph1a in Constantinople, describes the lighting of the entire church (see Appendix III). In the center of the church a lamp was suspended 37...

  13. An In-Situ Photometric and Energy Analysis of a Sulfur LampLighting System

    SciTech Connect (OSTI)

    Crawford, Doug; Gould, Carl; Packer, Michael; Rubinstein,Francis; Siminovitch, Michael

    1995-06-01T23:59:59.000Z

    This paper describes the results of a photometric and energy analysis that was conducted on a new light guide and sulfur lamp system recently installed at the U.S. Department of Energy's Forrestal Building. This novel system couples two high lumen output, high efficiency sulfur lamps to a single 73 m (240 ft.) hollow light guide lined with a reflective prismatic film. The system lights a large roadway and plaza area that lies beneath a section of the building. It has been designed to completely replace the grid of 280 mercury vapor lamps formerly used to light the space. This paper details the results of a field study that characterizes the significant energy savings and increased illumination levels that have been achieved. Comparisons to modeled HID lighting scenarios are also included.

  14. Electric lamp, base for use therewith and method of assembling same

    DOE Patents [OSTI]

    Hough, Harold L. (Beverly, MA); English, George J. (Reading, MA); Chakrabarti, Kirti B. (Danvers, MA)

    1989-02-14T23:59:59.000Z

    An electric lamp including a reflector, at least one conductive ferrule located within a surface of the reflector and a lead-in conductor electrically connected to the ferrule and extending within the reflector. The lamp includes a base having an insulative (e.g., ceramic) cap located substantially about the ferrule, barrier means (e.g., ceramic fiber) located within the cap to define an open chamber substantially about the ferrule, an electrical conductor (e.g., wire) extending within the cap and electrically connected (e.g., silver soldered) to the ferrule, and sealing means (e.g., high temperature cement) located within the cap to provide a seal therefore. The barrier means serves to separate the sealing means from the open chamber about the ferrule such that the heat generated by the ferrule can be vented through spaced apertures located within the cap's side wall. A method of assembling a base on an electric lamp is also provided.

  15. Backcoupling of acoustic streaming on the temperature field inside high-intensity discharge lamps

    E-Print Network [OSTI]

    Schwieger, Joerg; Wolff, Marcus; Manders, Freddy; Suijker, Jos

    2015-01-01T23:59:59.000Z

    Operating high-intensity discharge lamps in the high frequency range (20-300 kHz) provides energy-saving and cost reduction potentials. However, commercially available lamp drivers do not make use of this operating strategy because light intensity fluctuations and even lamp destruction are possible. The reason for the fluctuating discharge arc are acoustic resonances in this frequency range that are excited in the arc tube. The acoustic resonances in turn generate a fluid flow that is caused by the acoustic streaming effect. Here, we present a 3D multiphysics model to determine the influence of acoustic streaming on the temperature field in the vicinity of an acoustic eigenfrequency. In that case a transition from stable to instable behavior occurs. The model is able to predict when light flicker can be expected. The results are in very good accordance with accompanying experiments.

  16. Observed Minimum Illuminance Threshold for Night Market Vendors in Kenya who use LED Lamps

    SciTech Connect (OSTI)

    Johnstone, Peter; Jacobson, Arne; Mills, Evan; Radecsky, Kristen

    2009-03-21T23:59:59.000Z

    Creation of light for work, socializing, and general illumination is a fundamental application of technology around the world. For those who lack access to electricity, an emerging and diverse range of LED based lighting products hold promise for replacing and/or augmenting their current fuel-based lighting sources that are costly and dirty. Along with analysis of environmental factors, economic models for total cost-ofownership of LED lighting products are an important tool for studying the impacts of these products as they emerge in markets of developing countries. One important metric in those models is the minimum illuminance demanded by end-users for a given task before recharging the lamp or replacing batteries. It impacts the lighting service cost per unit time if charging is done with purchased electricity, batteries, or charging services. The concept is illustrated in figure 1: LED lighting products are generally brightest immediately after the battery is charged or replaced and the illuminance degrades as the battery is discharged. When a minimum threshold level of illuminance is reached, the operational time for the battery charge cycle is over. The cost to recharge depends on the method utilized; these include charging at a shop at a fixed price per charge, charging on personal grid connections, using solar chargers, and purchasing dry cell batteries. This Research Note reports on the observed"charge-triggering" illuminance level threshold for night market vendors who use LED lighting products to provide general and task oriented illumination. All the study participants charged with AC power, either at a fixed-price charge shop or with electricity at their home.

  17. Plasma spectroscopic study of an electrodeless HID lamp containing Tl and Zn

    SciTech Connect (OSTI)

    Takeda, Mamoru; Horii, Shigeru; Hochi, Akira [Matsushita Electric Industrial Co., Ltd., Kyoto (Japan). Lighting Research Lab.

    1996-12-31T23:59:59.000Z

    Recently the electrodeless HID lamps excited by microwaves have been studied intensively. Tl is well known as a material having strong green emission lines. In this study, Tl spectra excited by microwaves were reported in the cases of Tl only and Tl + Zn. Using the Elenbaas`s method of high pressure Hg lamp, the cause of Tl continuous spectrum was examined. From the ratio of radiative intensities of two lines, an average arc temperature in the bulb was estimated. Then excitation level of the continuous emission spectrum near the 600nm wavelength was calculated from the dependence of the radiative intensities on these arc temperatures.

  18. Power Conditioning and Control Applications for Energy Conservation

    E-Print Network [OSTI]

    Brushwood, J. S.

    1982-01-01T23:59:59.000Z

    Electrical power conditioning and control (PCC) systems are finding cost effective applications in AC motor drives, lamp ballasts and power supplies. Substantial system efficiency improvements are being realized when the appropriate PCC system...

  19. ISSUANCE 2015-06-25: Energy Conservation Program: Test Procedures for Integrated Light-Emitting Diode Lamps, Supplemental Notice of Proposed Rulemaking

    Broader source: Energy.gov [DOE]

    Energy Conservation Program: Test Procedures for Integrated Light-Emitting Diode Lamps, Supplemental Notice of Proposed Rulemaking

  20. ISSUANCE 2015-06-17: Energy Conservation Standards for Fluorescent Lamp Ballasts, Notice of Public Meeting and Availability of the Framework Document

    Broader source: Energy.gov [DOE]

    Energy Conservation Standards for Fluorescent Lamp Ballasts, Notice of Public Meeting and Availability of the Framework Document

  1. The Model 5000-16C 1000 WATT FEL Lamp Standard pro-vides absolute calibration of spectral irradiance from 250 nm to

    E-Print Network [OSTI]

    The Model 5000-16C 1000 WATT FEL Lamp Standard pro- vides absolute calibration of spectral irradiance from 250 nm to 2.5 microns.This Tungsten-Halogen Lamp Standard bears the ANSI designation of FEL might be discernible at the crossover point of the two referenced NIST Scales. 5000 FEL 1000Watt Lamp

  2. DOE Publishes CALiPER Report on Linear (T8) LED Lamps in Recessed Troffers

    Broader source: Energy.gov [DOE]

    The U.S. Department of Energy's CALiPER program has released Report 21.2, which is part of a series of investigations on linear LED lamps. Report 21.2 focuses on the performance of three linear (T8...

  3. DOE Publishes CALiPER Report on Cost-Effectiveness of Linear (T8) LED Lamps

    Broader source: Energy.gov [DOE]

    The U.S. Department of Energy's CALiPER program has released Report 21.3, which is part of a series of investigations on linear LED lamps. Report 21.3 details a set of life-cycle cost simulations...

  4. RF driven sulfur lamp having driving electrodes which face each other

    DOE Patents [OSTI]

    Gabor, G.; Orr, T.R.; Greene, C.M.; Crawford, D.G.; Berman, S.M.

    1999-06-22T23:59:59.000Z

    A high intensity discharge lamp without mercury is disclosed radiating a selected spectrum of which can be almost entirely in the visible range from an envelope that contains a sulfur containing substance. The lamp utilizes a signal source that generates an excitation signal that is externally coupled to the exterior surface of the envelope to excite the enclosed sulfur containing substance. Various embodiments of the lamp use electrodes adjacent the envelope to couple the excitation signal thereto with the face of the electrodes shaped to complement the shape of the exterior surface of the envelope. Two shapes discussed are spherical and cylindrical. To minimize filamentary discharges each envelope may include an elongated stem affixed to the exterior thereof whereby a rotational subsystem spins the envelope. In yet another embodiment the envelope has a Dewar configuration with two electrodes, one positioned near the external curved side surface of the body, and a second to the inner surface of the hole through the envelope. Further, the envelope may contain a backfill of a selected inert gas to assist in the excitation of lamp with that backfill at a pressure of less than 1 atmosphere, wherein the backfill pressure is directly related to the increase or decrease of peak output and inversely related to the increase and decrease of the emitted spectrum from the envelope. The emitting fill can be less than 6 mg/cc, or at least 2 mg/cc of the envelope of a sulfur containing substance. 17 figs.

  5. Transport phenomena in metal-halide lamps a poly-diagnostic study

    E-Print Network [OSTI]

    Eindhoven, Technische Universiteit

    UNIVERSITEIT EINDHOVEN Nimalasuriya, Tanya Transport phenomena in metal-halide lamps : a poly-diagnostic study / by Tanya Nimalasuriya. - Eindhoven : Technische Universiteit Eindhoven, 2007. Proefschrift. ISBN 978 aan de Technische Universiteit Eindhoven, op gezag van de Rector Magnificus, prof.dr.ir. C.J. van

  6. Method and apparatus for powering an electrodeless lamp with reduced radio frequency interference

    DOE Patents [OSTI]

    Simpson, James E. (Gaithersburg, MD)

    1999-01-01T23:59:59.000Z

    An electrodeless lamp waveguide structure includes tuned absorbers for spurious RF signals. A lamp waveguide with an integral frequency selective attenuation includes resonant absorbers positioned within the waveguide to absorb spurious out-of-band RF energy. The absorbers have a negligible effect on energy at the selected frequency used to excite plasma in the lamp. In a first embodiment, one or more thin slabs of lossy magnetic material are affixed to the sidewalls of the waveguide at approximately one quarter wavelength of the spurious signal from an end wall of the waveguide. The positioning of the lossy material optimizes absorption of power from the spurious signal. In a second embodiment, one or more thin slabs of lossy magnetic material are used in conjunction with band rejection waveguide filter elements. In a third embodiment, one or more microstrip filter elements are tuned to the frequency of the spurious signal and positioned within the waveguide to couple and absorb the spurious signal's energy. All three embodiments absorb negligible energy at the selected frequency and so do not significantly diminish the energy efficiency of the lamp.

  7. Method and apparatus for powering an electrodeless lamp with reduced radio frequency interference

    DOE Patents [OSTI]

    Simpson, J.E.

    1999-06-08T23:59:59.000Z

    An electrodeless lamp waveguide structure includes tuned absorbers for spurious RF signals. A lamp waveguide with an integral frequency selective attenuation includes resonant absorbers positioned within the waveguide to absorb spurious out-of-band RF energy. The absorbers have a negligible effect on energy at the selected frequency used to excite plasma in the lamp. In a first embodiment, one or more thin slabs of lossy magnetic material are affixed to the sidewalls of the waveguide at approximately one quarter wavelength of the spurious signal from an end wall of the waveguide. The positioning of the lossy material optimizes absorption of power from the spurious signal. In a second embodiment, one or more thin slabs of lossy magnetic material are used in conjunction with band rejection waveguide filter elements. In a third embodiment, one or more microstrip filter elements are tuned to the frequency of the spurious signal and positioned within the waveguide to couple and absorb the spurious signal's energy. All three embodiments absorb negligible energy at the selected frequency and so do not significantly diminish the energy efficiency of the lamp. 18 figs.

  8. RF driven sulfur lamp having driving electrodes which face each other

    DOE Patents [OSTI]

    Gabor, George (Lafayette, CA); Orr, Thomas Robert (Castro Valley, CA); Greene, Charles Maurice (Oakland, CA); Crawford, Douglas Gordon (Orinda, CA); Berman, Samuel Maurice (San Francisco, CA)

    1999-01-01T23:59:59.000Z

    A high intensity discharge lamp without mercury is disclosed radiating a selected spectrum of which can be almost entirely in the visible range from an envelope that contains a sulfur containing substance. The lamp utilizes a signal source that generates an excitation signal that is externally coupled to the exterior surface of the envelope to excite the enclosed sulfur containing substance. Various embodiments of the lamp use electrodes adjacent the envelope to couple the excitation signal thereto with the face of the electrodes shaped to complement the shape of the exterior surface of the envelope. Two shapes discussed are spherical and cylindrical. To minimize filamentary discharges each envelope may include an elongated stem affixed to the exterior thereof whereby a rotational subsystem spins the envelope. In yet another embodiment the envelope has a Dewar configuration with two electrodes, one positioned near the external curved side surface of the body, and a second to the inner surface of the hole through the envelope. Further, the envelope may contain a backfill of a selected inert gas to assist in the excitation of lamp with that backfill at a pressure of less than 1 atmosphere, wherein the backfill pressure is directly related to the increase or decrease of peak output and inversely related to the increase and decrease of the emitted spectrum from the envelope. The emitting fill can be less than 6 mg/cc, or at least 2 mg/cc of the envelope of a sulfur containing substance.

  9. Demonstration Of A Monitoring Lamp To Visualize The Energy Consumption In Houses

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    the sources of consumption. Automated monitoring of the electricity consumption in a house is quite a recent or numbers, but simply alert residents that something relevant to their electricity consumption is chang- ingDemonstration Of A Monitoring Lamp To Visualize The Energy Consumption In Houses Christophe Gisler1

  10. Issues In the Design and Specification of Class Libraries Gregor Kiczales and John Lamping

    E-Print Network [OSTI]

    Introduction Object-oriented programming has been praised for many virtues, of which we believe code reuse that require their sort of functionality, we can reuse the library rather than having to code again from; Gregor@parc.xerox.com, Lamping@parc.xerox.com. c 1992 Association of Computing Machinery. Permission

  11. RG: A Case-Study for Aspect-Oriented Programming Anurag Mendhekar, Gregor Kiczales, John Lamping

    E-Print Network [OSTI]

    to be sprinkled throughout the code, resulting in code that tangled the various performance issues along 3333 Coyote Hill Road, Palo Alto, CA 94304, USA. {anurag,gregor,lamping}@parc.xerox.com #12;22 Aspect-cutting issues. In AOP, code relating to cross-cutting issues, called aspects, can be written in a way that need

  12. What A Metaobject Protocol Based Compiler Can Do For Lisp Gregor Kiczales, John Lamping, Anurag Mendhekar

    E-Print Network [OSTI]

    Mendhekar Xerox PARC Internal Report, December 1993. © Copyright 1993 Xerox Corporation. All rights reserved allows programmers to cleanly, concisely and portably code the following examples, and have them work Hill Rd., Palo Alto, CA 94304; (415)812-4888; Gregor--Lamping@parc.xerox.com. 1 #12;Internal Memo -- c

  13. Predicted Pulsed-Power/Flash-Lamp Performance of the NIF Main Amplifier

    SciTech Connect (OSTI)

    Fulkerson, E. Steven; Hammond, Jud; Harjes, Henry C.; Moore, William B.S.; Smith, David L.; Wilson, J. Michael

    1999-06-22T23:59:59.000Z

    The laser glass for the National Ignition Facility (NIF) Main Amplifier system is pumped by a system of 192 pulsed power/flash lamp assemblies. Each of these 192 assemblies consists of a 1.6 MJ (nominal) capacitor bank working with a Pre-Ionization/Lamp Check (PILC) pulser to drive an array of 40 flash lamps. This paper describes the predicted performance of these Power Conditioning System (PCS) modules in concert with flashlamp assemblies in NIF. Each flashlamp assembly consists of 20 parallel sets of lamps in series pairs. The sensitivity of system performance to various design parameters of the PILC pulser and the main capacitor bank is described. Results of circuit models are compared to sub-scale flashlamp tests and to measurements taken in tests of a PCS module driving a flashlamp assembly in the First Article NIF Test Module facility at Sandia National Laboratories. Also included are predictions from a physics-based, semi-empirical amplifier gain code.

  14. Women in Science The Lady with the Lamp 100 years on Prof. Sylvia Draper

    E-Print Network [OSTI]

    O'Mahony, Donal E.

    into current (or vice versa) provides us with the capacity to devise efficient solar cells or LightemittingWomen in Science ­ The Lady with the Lamp ­ 100 years on Prof. Sylvia Draper Florence Nightingale was an inspiration to the wounded and the dying in the Crimean war and to future generations of women who wanted

  15. THIN NANOPOROUS TITANIA FILMS ON THE ELECTRODELESS DISCHARGE LAMPS FOR PHOTOCATALYSIS

    E-Print Network [OSTI]

    Cirkva, Vladimir

    THIN NANOPOROUS TITANIA FILMS ON THE ELECTRODELESS DISCHARGE LAMPS FOR PHOTOCATALYSIS Vladimír: cirkva@icpf.cas.cz, http://home.icpf.cas.cz/cirkva Keywords: Microwave assisted photocatalysis. Introduction Photocatalysis is an efficient, attractive and clean technology for pollution abatement in water

  16. Stress Testing of the Philips 60W Replacement Lamp L Prize Entry

    SciTech Connect (OSTI)

    Poplawski, Michael E.; Ledbetter, Marc R.; Smith, Mark

    2012-04-24T23:59:59.000Z

    The Pacific Northwest National Laboratory, operated by Battelle for the U.S. Department of Energy, worked with Intertek to develop a procedure for stress testing medium screw-base light sources. This procedure, composed of alternating stress cycles and performance evaluation, was used to qualitatively compare and contrast the durability and reliability of the Philips 60W replacement lamp L Prize entry with market-proven compact fluorescent lamps (CFLs) with comparable light output and functionality. The stress cycles applied simultaneous combinations of electrical, thermal, vibration, and humidity stresses of increasing magnitude. Performance evaluations measured relative illuminance, x chromaticity and y chromaticity shifts after each stress cycle. The Philips L Prize entry lamps appear to be appreciably more durable than the incumbent energy-efficient technology, as represented by the evaluated CFLs, and with respect to the applied stresses. Through the course of testing, all 15 CFL samples permanently ceased to function as a result of the applied stresses, while only 1 Philips L Prize entry lamp exhibited a failure, the nature of which was minor, non-destructive, and a consequence of a known (and resolved) subcontractor issue. Given that current CFL technology appears to be moderately mature and no Philips L Prize entry failures could be produced within the stress envelope causing 100 percent failure of the benchmark CFLs, it seems that, in this particular implementation, light-emitting diode (LED) technology would be much more durable in the field than current CFL technology. However, the Philips L Prize entry lamps used for testing were carefully designed and built for the competition, while the benchmark CFLs were mass produced for retail sale—a distinction that should be taken into consideration. Further reliability testing on final production samples would be necessary to judge the extent to which the results of this analysis apply to production versions of the Philips L Prize entry.

  17. Demonstration of LED Retrofit Lamps at an Exhibit of 19th Century Photography at the Getty Museum

    SciTech Connect (OSTI)

    Miller, Naomi J.; Druzik, Jim

    2012-03-02T23:59:59.000Z

    This document is a report of observations and results obtained from a lighting demonstration project conducted under the U.S. Department of Energy (DOE) GATEWAY Demonstration Program. The program supports demonstrations of high-performance solid-state lighting (SSL) products in order to develop empirical data and experience with in-the-field applications of this advanced lighting technology. The DOE GATEWAY Demonstration Program focuses on providing a source of independent, third-party data for use in decision-making by lighting users and professionals; this data should be considered in combination with other information relevant to the particular site and application under examination. Each GATEWAY Demonstration compares SSL products against the incumbent technologies used in that location. Depending on available information and circumstances, the SSL product may also be compared to alternate lighting technologies. Though products demonstrated in the GATEWAY program may have been prescreened for performance, DOE does not endorse any commercial product or in any way guarantee that users will achieve the same results through use of these products. This report reviews the installation and use of LED PAR38 lamps to light a collection of toned albument photographic prints at the J. Paul Getty Museum in Malibu, California. Research results provided by the Getty Conservation Institute are incorporated and discussed.

  18. CALiPER Report 20.1: Quality of Beam, Shadow, and Color in LED PAR38 Lamps

    Broader source: Energy.gov [DOE]

    View the video about CALiPER Report 20.1 which focuses on human-evaluated characteristics, including beam quality, shadow quality, and color quality in LED PAR38 lamps.

  19. DOE Publishes CALiPER Report on Linear (T8) LED Lamps in a 2x4...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    than those with a wide distribution (i.e., with a diffuse optic), and all of the linear LED lamps resulted in a higher luminaire efficiency than the fluorescent benchmark. The...

  20. CENTRIFUGAL LABTUBE FOR FULLY AUTOMATED DNA EXTRACTION & LAMP AMPLIFICATION BASED ON AN INTEGRATED, LOW-COST HEATING SYSTEM

    E-Print Network [OSTI]

    Hoehl, Melanie Margarete

    In this paper, we introduce a disposable battery-driven heating system for loop-mediated isothermal DNA amplification (LAMP) inside a centrifugally-driven DNA-extraction platform (LabTube). We demonstrate fully automated, ...

  1. Numerical Investigation of Symmetry Breaking and Critical Behavior of the Acoustic Streaming Field in High-Intensity Discharge Lamps

    E-Print Network [OSTI]

    Baumann, Bernd; Wolff, Marcus; Manders, Freddy; Suijker, Jos

    2014-01-01T23:59:59.000Z

    For energy efficiency and material cost reduction it is preferred to drive high-intensity discharge lamps at frequencies of approximately 300 kHz. However, operating lamps at these high frequencies bears the risk of stimulating acoustic resonances inside the arc tube, which can result in low frequency light flicker and even lamp destruction. The acoustic streaming effect has been identified as the link between high frequency resonances and low frequency flicker. A highly coupled 3D multiphysics model has been set up to calculate the acoustic streaming velocity field inside the arc tube of high-intensity discharge lamps. It has been found that the velocity field suffers a phase transition to an asymmetrical state at a critical acoustic streaming force. The system behaves similar to a ferromagnet near the Curie point. Furthermore, it is discussed how the model allows to investigate the light flicker phenomenon. Concerning computer resources the procedure is considerably less demanding than a direct approach wit...

  2. Treatability study for removal of leachable mercury in crushed fluorescent lamps

    SciTech Connect (OSTI)

    Bostick, W.D.; Beck, D.E.; Bowser, K.T. [and others

    1996-02-01T23:59:59.000Z

    Nonserviceable fluorescent lamps removed from radiological control areas at the Oak Ridge Department of Energy facilities have been crushed and are currently managed as mixed waste (hazardous and radiologically contaminated). We present proposed treatment flowsheets and supporting treatability study data for conditioning this solid waste residue so that it can qualify for disposal in a sanitary landfill. Mercury in spent fluorescent lamps occurs primarily as condensate on high-surface-area phosphor material. It can be solubilized with excess oxidants (e.g., hypochlorite solution) and stabilized by complexation with halide ions. Soluble mercury in dechlorinated saline solution is effectively removed by cementation with zero-valent iron in the form of steel wool. In packed column dynamic flow testing, soluble mercury was reduced to mercury metal and insoluble calomel, loading > 1.2 g of mercury per grain of steel wool before an appreciable breakthrough of soluble mercury in the effluent.

  3. LED lamp or bulb with remote phosphor and diffuser configuration with enhanced scattering properties

    DOE Patents [OSTI]

    Tong, Tao; Le Toquin, Ronan; Keller, Bernd; Tarsa, Eric; Youmans, Mark; Lowes, Theodore; Medendorp, Jr., Nicholas W; Van De Ven, Antony; Negley, Gerald

    2014-11-11T23:59:59.000Z

    An LED lamp or bulb is disclosed that comprises a light source, a heat sink structure and an optical cavity. The optical cavity comprises a phosphor carrier having a conversions material and arranged over an opening to the cavity. The phosphor carrier comprises a thermally conductive transparent material and is thermally coupled to the heat sink structure. An LED based light source is mounted in the optical cavity remote to the phosphor carrier with light from the light source passing through the phosphor carrier. A diffuser dome is included that is mounted over the optical cavity, with light from the optical cavity passing through the diffuser dome. The properties of the diffuser, such as geometry, scattering properties of the scattering layer, surface roughness or smoothness, and spatial distribution of the scattering layer properties may be used to control various lamp properties such as color uniformity and light intensity distribution as a function of viewing angle.

  4. 2015-01-28 Issuance: Test Procedure for Fluorescent Lamp Ballasts; Final Rule Correction

    Broader source: Energy.gov [DOE]

    This document is a pre-publication Federal Register final rule correction regarding test procedures for fluorescent lamp ballasts, as issued by the Deputy Assistant Secretary for Energy Efficiency on January 28, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

  5. Electronic starter device for fluorescent lamps. Final report

    SciTech Connect (OSTI)

    NONE

    1998-06-01T23:59:59.000Z

    Due to silicon supplier failures to produce the 03/04 triac silicon as specified in the original proposal, the direction of the starter program was migrated to use available off the shelf power semiconductors. This had unexpected positive side effects including a reduction in component price, improved quality, and the refocus of engineering efforts to concentrate on the Super ASIC core technology. The starter program has begun shipments employing this new architecture, and is being well received both in the US and abroad. In its present form, the starter meets original cost projections within 20%. Work is continuing on the 0.8 micron ASIC, which will allow for the starter to sell below $1.00 in volume. Even at the slightly higher price, interest is strong in replacing the low performance glow starter for small fluorescent applications with a high performance alternative.

  6. Coaxial test fixture

    DOE Patents [OSTI]

    Praeg, W.F.

    1984-03-30T23:59:59.000Z

    This invention pertains to arrangements for performing electrical tests on contact material samples, and in particular for testing contact material test samples in an evacuated environment under high current loads. Frequently, it is desirable in developing high-current separable contact material, to have at least a preliminary analysis of selected candidate conductor materials. Testing of material samples will hopefully identify materials unsuitable for high current electrical contact without requiring incorporation of the materials into a completed and oftentimes complex structure.

  7. Load regulating expansion fixture

    DOE Patents [OSTI]

    Wagner, Lawrence M. (San Jose, CA); Strum, Michael J. (San Jose, CA)

    1998-01-01T23:59:59.000Z

    A free standing self contained device for bonding ultra thin metallic films, such as 0.001 inch beryllium foils. The device will regulate to a predetermined load for solid state bonding when heated to a bonding temperature. The device includes a load regulating feature, whereby the expansion stresses generated for bonding are regulated and self adjusting. The load regulator comprises a pair of friction isolators with a plurality of annealed copper members located therebetween. The device, with the load regulator, will adjust to and maintain a stress level needed to successfully and economically complete a leak tight bond without damaging thin foils or other delicate components.

  8. Load regulating expansion fixture

    DOE Patents [OSTI]

    Wagner, L.M.; Strum, M.J.

    1998-12-15T23:59:59.000Z

    A free standing self contained device for bonding ultra thin metallic films, such as 0.001 inch beryllium foils is disclosed. The device will regulate to a predetermined load for solid state bonding when heated to a bonding temperature. The device includes a load regulating feature, whereby the expansion stresses generated for bonding are regulated and self adjusting. The load regulator comprises a pair of friction isolators with a plurality of annealed copper members located therebetween. The device, with the load regulator, will adjust to and maintain a stress level needed to successfully and economically complete a leak tight bond without damaging thin foils or other delicate components. 1 fig.

  9. Method of controlling the mercury vapor pressure in a photo-chemical lamp or vapor filter used for Hg.sup.196 enrichment

    DOE Patents [OSTI]

    Grossman, Mark W. (Belmont, MA)

    1993-01-01T23:59:59.000Z

    The present invention is directed to a method of eliminating the cold spot zones presently used on Hg.sup.196 isotope separation lamps and filters by the use of a mercury amalgams, preferably mercury - indium amalgams. The use of an amalgam affords optimization of the mercury density in the lamp and filter of a mercury enrichment reactor, particularly multilamp enrichment reactors. Moreover, the use of an amalgam in such lamps and/or filters affords the ability to control the spectral line width of radiation emitted from lamps, a requirement for mercury enrichment.

  10. Method of controlling the mercury vapor pressure in a photo-chemical lamp or vapor filter used for Hg[sup 196] enrichment

    DOE Patents [OSTI]

    Grossman, M.W.

    1993-02-16T23:59:59.000Z

    The present invention is directed to a method of eliminating the cold spot zones presently used on Hg[sup 196] isotope separation lamps and filters by the use of a mercury amalgams, preferably mercury - indium amalgams. The use of an amalgam affords optimization of the mercury density in the lamp and filter of a mercury enrichment reactor, particularly multilamp enrichment reactors. Moreover, the use of an amalgam in such lamps and/or filters affords the ability to control the spectral line width of radiation emitted from lamps, a requirement for mercury enrichment.

  11. DOE Publishes CALiPER Application Summary Report on LED MR16 Lamps |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: Theof"WaveInteractions and Policy (2009)

  12. As you know, water costs continue to rise, but you can do something to help yourself. Households can check their plumbing fixtures and irrigation systems for leaks. This checklist will

    E-Print Network [OSTI]

    . Households can check their plumbing fixtures and irrigation systems for leaks. This checklist will help you a certification program focused on water efficiency to ensure that your in-ground irrigation system is not leaking tape and a wrench. 8. Consult with an irrigation installer (WaterSense partner) who has passed

  13. A high-efficiency indirect lighting system utilizing the solar 1000 sulfur lamp

    SciTech Connect (OSTI)

    Siminovitch, M.; Gould, C.; Page, E.

    1997-06-01T23:59:59.000Z

    High-lumen light sources represent unique challenges and opportunities for the design of practical and efficient interior lighting systems. High-output sources require a means of large-scale distribution and avoidance of high-luminance glare while providing efficient delivery. An indirect lighting system has been developed for use with a 1,000 Watt sulfur lamp that efficiently utilizes the high-output source to provide quality interior lighting. This paper briefly describes the design and initial testing of this new system.

  14. Lighting Options for Homes.

    SciTech Connect (OSTI)

    Baker, W.S.

    1991-04-01T23:59:59.000Z

    This report covers many aspects of various lighting options for homes. Types of light sources described include natural light, artificial light, incandescent lamps, fluorescent lamps, and high intensity discharge lamps. A light source selection guide gives the physical characteristics of these, design considerations, and common applications. Color, strategies for efficient lighting, and types of lighting are discussed. There is one section giving tips for various situations in specific rooms. Rooms and types of fixtures are shown on a matrix with watts saved by using the recommended type lighting for that room and room location. A major emphasis of this report is saving energy by utilizing the most suitable, recommended lighting option. (BN)

  15. Lamp Divisions

    Office of Legacy Management (LM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOn AprilA group currentBradleyTableSelling CorpNewCF INDUSTRIES,L? .-I I2 m.m\ LILTS PlanI9

  16. Long-term evaluation of solid oxide fuel cell candidate materials in a 3-cell generic short stack fixture, Part II: sealing glass stability, microstructure and interfacial reactions.

    SciTech Connect (OSTI)

    Chou, Y. S.; Stevenson, Jeffry W.; Choi, Jung-Pyung

    2014-03-15T23:59:59.000Z

    A generic solid oxide fuel cell stack test fixture was developed to evaluate candidate materials and processing methods under realistic conditions. Part I of the work addressed the stack fixture, seal system and cell performance of a 3-cell short stack tested at 800oC for 6000h. Commercial NiO-YSZ anode-supported thin YSZ electrolyte cells with LSM cathodes were used for assessment and were tested in constant current mode with dilute (~50% H2) fuel versus air. Part II of the work examined the sealing glass stability, microstructure development, interfacial reactions, and volatility issues. Part III of the work investigated the stability of Ce-(Mn,Co) spinel coating, AISI441 metallic interconnect, alumina coating, and cell degradation. After 6000h of testing, the refractory sealing glass YSO77 (Ba-Sr-Y-B-Si) showed desirable chemical compatibility with YSZ electrolyte in that no discernable interfacial reaction was identified, consistent with thermodynamic calculations. In addition, no glass penetration into the thin electrolyte was observed. At the aluminized AISI441 interface, the protective alumina coating appeared to be corroded by the sealing glass. Air side interactions appeared to be more severe than fuel side interactions. Metal species such as Cr, Mn, and Fe were detected in the glass, but were limited to the vicinity of the interface. No alkaline earth chromates were found at the air side. Volatility was also studied in a similar glass and weight loss in a wet reducing environment was determined. Using the steady-state volatility data, the life time (40,000h) weight loss of refractory sealing glass YSO77 was estimated to be less than 0.1 wt%.

  17. Jade Sky Technologies Partners with CLTC on LED Replacement Lamp Upgrade Project UC Davis' California Lighting Technology Center will utilize Jade Sky Technologies' driver ICs to help spur

    E-Print Network [OSTI]

    California at Davis, University of

    Jade Sky Technologies Partners with CLTC on LED Replacement Lamp Upgrade Project UC Davis and power factor. "JST shares our goal of making the transition to LED lamps a satisfying experience of cost-effective, easy-to-use LED lighting solutions Milpitas, Calif. ­ October 15, 2013 ­ Jade Sky

  18. Tomorrow's cities -the lamp-posts watching every move1 by Jane Wakefield for BBC News2

    E-Print Network [OSTI]

    South Bohemia, University of

    the city council is looking to upgrade its23 streetlights to more energy-efficient LED lights - likely in the area. The pilot project will be integrated with the newly built City Operations Centre, where CCTVTomorrow's cities - the lamp-posts watching every move1 by Jane Wakefield for BBC News2 3 Imagine

  19. DOE Publishes CALiPER Report on Dimming, Flicker, and Power Quality Characteristics of LED PAR38 Lamps

    Broader source: Energy.gov [DOE]

    The U.S. Department of Energy's CALiPER program has released Report 20.2, which is part of a series of investigations on LED PAR38 lamps. Report 20.2 focuses on dimming, flicker, and power quality...

  20. Macros that Reach Out and Touch Somewhere Gregor Kiczales, John Lamping, Luis H. Rodriguez Jr., and Erik Ruf

    E-Print Network [OSTI]

    ., and Erik Ruf Xerox PARC Internal Report, December 1991. © Copyright 1991 Xerox Corporation. All rights Xerox Corporation Gregor Kiczales, John Lamping, Luis Rodriguez and Erik Ruf Xerox PARC By providing, and insert the necessary coercions. The code stays clean, and there is no chance of missing a coercion. Both

  1. NIST energy related inventions: Electronic starter device for fluorescent lamps. Interim report, August--October, 1997

    SciTech Connect (OSTI)

    Johnson, S.A.

    1997-12-01T23:59:59.000Z

    From the Scope of Work document which accompanied the original proposal, three silicon devices were anticipated for development, simulation, and quality assurance fabrication. The status of these are in the same format as the Scope of Work...Attachment-A-: Task 1--design and simulation; Task 2--prototype tooling; Task 3--test engineering; Task 4--product tooling; Task 5--package tooling/manufacturing design and assembly. It is felt the program will meet it`s stated goals of producing a low cost, high performance fluorescent lamp starter which will lower the acquisition and operating cost of fluorescent technology...thus saving significant amounts of energy. The likelihood of success is even greater, now that the TN22 component has been qualified. The challenges of creating a custom ASIC, while still significant, are within the skill and expertise level or the assigned engineers.

  2. DOE CALiPER Program, Report 21.2: Linear (T8) LED Lamp Performance in Five Types of Recessed Troffers

    SciTech Connect (OSTI)

    Miller, Naomi J.; Perrin, Tess E.; Royer, Michael P.; Wilkerson, Andrea M.; Beeson, Tracy A.

    2014-05-20T23:59:59.000Z

    Although lensed troffers are numerous, there are many other types of optical systems as well. This report looked at the performance of three linear (T8) LED lamps chosen primarily based on their luminous intensity distributions (narrow, medium, and wide beam angles) as well as a benchmark fluorescent lamp in five different troffer types. Also included are the results of a subjective evaluation. Results show that linear (T8) LED lamps can improve luminaire efficiency in K12-lensed and parabolic-louvered troffers, effect little change in volumetric and high-performance diffuse-lensed type luminaires, but reduce efficiency in recessed indirect troffers. These changes can be accompanied by visual appearance and visual comfort consequences, especially when LED lamps with clear lenses and narrow distributions are installed. Linear (T8) LED lamps with diffuse apertures exhibited wider beam angles, performed more similarly to fluorescent lamps, and received better ratings from observers. Guidance is provided on which luminaires are the best candidates for retrofitting with linear (T8) LED lamps.

  3. Program Name: Simple Steps, Smart Savings Simple Steps, Smart...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    and install high-quality, energy-efficient compact fluorescent lamps (CFLs), light emitting diode bulbs (LEDs), light fixtures and energy-saving showerheads. Beginning in...

  4. CA-TRIBE-SUSANVILLE INDIAN RANCHERIA, CALIFORNIA

    Broader source: Energy.gov (indexed) [DOE]

    lighting fixtures and lighting upgrades; conversion of exit signs to light- emitting diode; replacement of T-12 lamps and ballasts; heating, ventilating, and air...

  5. CX-002214: Categorical Exclusion Determination | Department of...

    Broader source: Energy.gov (indexed) [DOE]

    efficient lighting fixtures and lighting upgrades; conversion of exit signs to light-emitting diode; replacement of T-12 lamps and ballasts; heating, ventilating, and air...

  6. Data:Bce07014-bc93-4029-9f9c-757c54b71d14 | Open Energy Information

    Open Energy Info (EERE)

    Rate name: Public Street Lighting Service - HPSV Lamp Fixtures - Breakaway Base SteelConcrete Pole - Company Owned Sector: Lighting Description: To the City of Independence for...

  7. Data:1930475c-e431-4492-94ce-c461d1003207 | Open Energy Information

    Open Energy Info (EERE)

    Public Street Lighting Service - HPSV Double Mastarm Lamp Fixtures - Standard SteelConcrete Pole - Company Owned Sector: Lighting Description: To the City of Independence for...

  8. Data:632c1b2a-49c4-48cc-bbbf-ef05c119725f | Open Energy Information

    Open Energy Info (EERE)

    Lighting Service - HPSV Double Mastarm Lamp Fixtures - Breakaway Base Standard SteelConcrete Pole - Company Owned Sector: Lighting Description: To the City of Independence for...

  9. Data:D153e05a-9026-4559-814a-c5856890bfe6 | Open Energy Information

    Open Energy Info (EERE)

    known: Rate name: Public Street Lighting Service - HPSV Lamp Fixtures (Standard SteelConcrete Pole) Sector: Lighting Description: To the City of Independence for all Public Street...

  10. Data:444e19b9-9c6d-454b-89ad-b4850520f3fc | Open Energy Information

    Open Energy Info (EERE)

    including lamps, fixtures, controls, and the necessary street lighting circuits, transformers, and additional guys and fittings will be owner, maintained, and operated by the...

  11. Data:6575a792-eabd-4b02-9eef-85c59473de86 | Open Energy Information

    Open Energy Info (EERE)

    consists of installations requiring more than one wood pole and special poles, transformers, line extensions, non-standard fixtures and lamps, or underground service. The CIAC...

  12. Data:764960a6-c576-432f-b6bf-21b862270742 | Open Energy Information

    Open Energy Info (EERE)

    consists of installations requiring more than one wood pole and special poles, transformers, line extensions, non-standard fixtures and lamps, or underground service. The CIAC...

  13. Data:1af4c76f-e1f6-4369-a579-8ca93962f51a | Open Energy Information

    Open Energy Info (EERE)

    consists of installations requiring more than one wood pole and special poles, transformers, line extensions, non-standard fixtures and lamps, or underground service. The CIAC...

  14. Data:542f2c16-2ec9-4b3d-91e7-e549c4f91041 | Open Energy Information

    Open Energy Info (EERE)

    including lamps, fixtures, controls, and the necessary street lighting circuits, transformers, and additional guys and fittings will be owner, maintained, and operated by the...

  15. Data:8aad2056-ab83-42e0-bbcb-b50684125135 | Open Energy Information

    Open Energy Info (EERE)

    consists of installations requiring more than one wood pole and special poles, transformers, line extensions, non-standard fixtures and lamps, or underground service. The CIAC...

  16. Data:6719e7d8-c345-4442-9157-9afdec2b80d4 | Open Energy Information

    Open Energy Info (EERE)

    consists of installations requiring more than one wood pole and special poles, transformers, line extensions, non-standard fixtures and lamps, or underground service. The CIAC...

  17. Data:C065f3c8-dc3d-439c-b2c9-a36550974098 | Open Energy Information

    Open Energy Info (EERE)

    including lamps, fixtures, controls, and the necessary street lighting circuits, transformers, and additional guys and fittings will be owner, maintained, and operated by the...

  18. Data:67284124-67a7-4048-a984-4583bcce8b76 | Open Energy Information

    Open Energy Info (EERE)

    consists of installations requiring more than one wood pole and special poles, transformers, line extensions, non-standard fixtures and lamps, or underground service. The CIAC...

  19. Data:23ff7a80-4be0-4b02-bb6f-e4d20400b3b9 | Open Energy Information

    Open Energy Info (EERE)

    consists of installations requiring more than one wood pole and special poles, transformers, line extensions, non-standard fixtures and lamps, or underground service. The CIAC...

  20. Data:5e08d776-ee27-45f9-aaad-525bd6da11d9 | Open Energy Information

    Open Energy Info (EERE)

    consists of installations requiring more than one wood pole and special poles, transformers, line extensions, non-standard fixtures and lamps, or underground service. The CIAC...

  1. Data:29bd8186-4b4c-4b51-81ff-12f81406d406 | Open Energy Information

    Open Energy Info (EERE)

    consists of installations requiring more than one wood pole and special poles, transformers, line extensions, non-standard fixtures and lamps, or underground service. The CIAC...

  2. Data:051c3942-71cb-4dd1-a0a4-1700d8264c5a | Open Energy Information

    Open Energy Info (EERE)

    consists of installations requiring more than one wood pole and special poles, transformers, line extensions, non-standard fixtures and lamps, or underground service. The CIAC...

  3. Data:615b6889-81e2-4856-b606-330381a0bc75 | Open Energy Information

    Open Energy Info (EERE)

    consists of installations requiring more than one wood pole and special poles, transformers, line extensions, non-standard fixtures and lamps, or underground service. The CIAC...

  4. Data:0d4ca450-7514-4217-8297-b3990e102a46 | Open Energy Information

    Open Energy Info (EERE)

    consists of installations requiring more than one wood pole and special poles, transformers, line extensions, non-standard fixtures and lamps, or underground service. The CIAC...

  5. Data:B67808a7-3e12-4f95-8802-dbed6cb31955 | Open Energy Information

    Open Energy Info (EERE)

    consists of installations requiring more than one wood pole and special poles, transformers, line extensions, non-standard fixtures and lamps, or underground service. The CIAC...

  6. Data:793b9036-c6d7-4f3c-83d2-0054ed12d1fa | Open Energy Information

    Open Energy Info (EERE)

    consists of installations requiring more than one wood pole and special poles, transformers, line extensions, non-standard fixtures and lamps, or underground service. The CIAC...

  7. Data:E6ce9c2f-968c-4efd-8409-edb975efda7c | Open Energy Information

    Open Energy Info (EERE)

    including lamps, fixtures, controls, and the necessary street lighting circuits, transformers, and additional guys and fittings will be owner, maintained, and operated by the...

  8. Data:1a8ddee4-b7a8-41d5-8269-b09e71c397f9 | Open Energy Information

    Open Energy Info (EERE)

    consists of installations requiring more than one wood pole and special poles, transformers, line extensions, non-standard fixtures and lamps, or underground service. The CIAC...

  9. Data:3c4f38a9-a290-47ff-9e09-32abe7803a47 | Open Energy Information

    Open Energy Info (EERE)

    consists of installations requiring more than one wood pole and special poles, transformers, line extensions, non-standard fixtures and lamps, or underground service. The CIAC...

  10. Data:67ca0256-b51d-413c-8c16-0924aea0c298 | Open Energy Information

    Open Energy Info (EERE)

    consists of installations requiring more than one wood pole and special poles, transformers, line extensions, non-standard fixtures and lamps, or underground service. The CIAC...

  11. Data:16c12927-1686-4cc5-83a9-58827bff3a72 | Open Energy Information

    Open Energy Info (EERE)

    Company) Effective date: 20130701 End date if known: Rate name: Public Street Lighting Service - HPSV Lamp Fixture - Contemporary Aluminum Pole - Company Owned -...

  12. Data:5d9bd42f-6353-4e87-8e65-9d378f3363f6 | Open Energy Information

    Open Energy Info (EERE)

    Company) Effective date: 20130701 End date if known: Rate name: Public Street Lighting Service - HPSV Double Mastarm Lamp Fixtures -Contemporary aluminum pole Sector:...

  13. Data:25132ac7-c487-49fd-bebb-2f7e82bccf95 | Open Energy Information

    Open Energy Info (EERE)

    Company) Effective date: 20130701 End date if known: Rate name: Public Street Lighting Service - HPSV Lamp Fixtures - Contemporary aluminum pole Sector: Lighting...

  14. Data:097bd602-838d-4236-a421-3869e589b008 | Open Energy Information

    Open Energy Info (EERE)

    Company) Effective date: 20130701 End date if known: Rate name: Public Street Lighting Service - HPSV Lamp Fixture - Ornamental Metal Post Pole - Company Owned Sector:...

  15. Data:01d32474-b6d4-4449-8c25-1ce0f2e3378a | Open Energy Information

    Open Energy Info (EERE)

    Company) Effective date: 20130701 End date if known: Rate name: Public Street Lighting Service - HPSV Lamp Fixtures - Breakaway Base Standard Steel Pole Sector: Lighting...

  16. Data:15c8e854-dabc-4fe0-9199-a4234ddd31a5 | Open Energy Information

    Open Energy Info (EERE)

    Company) Effective date: 20130701 End date if known: Rate name: Public Street Lighting Service - HPSV Lamp Fixtures - Breakaway Base Contemporary Aluminum Pole - Company...

  17. Data:B01ce61b-e9d8-49ee-ab97-5e762ab49bed | Open Energy Information

    Open Energy Info (EERE)

    Company) Effective date: 20130701 End date if known: Rate name: Public Street Lighting Service - HPSV Lamp Fixtures - Standard SteelConcrete Pole - Company Owned Sector:...

  18. Data:B0993536-b649-466f-b2b7-92bd7d6d30f2 | Open Energy Information

    Open Energy Info (EERE)

    Company) Effective date: 20130701 End date if known: Rate name: Public Street Lighting Service - HPSV Pendant Lamp Fixtures - Ornamental Pole - Residential Sector: Lighting...

  19. Data:Af9d2db7-299a-4f61-a63e-eaa291e2ec6c | Open Energy Information

    Open Energy Info (EERE)

    Company) Effective date: 20130701 End date if known: Rate name: Public Street Lighting Service - HPSV Double Lamp Fixture - Ornamental Metal Post Pole - Company Owned...

  20. Data:E37b36ec-074a-421d-9dcc-33030e5bf126 | Open Energy Information

    Open Energy Info (EERE)

    Street Lighting Service - HPSV Double Mastarm Lamp Fixtures - Breakaway Base Standard Steel Pole Sector: Lighting Description: To the City of Independence for all Public Street...

  1. Residential Clothes Dryer (Appendix D2) | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    Clothes Dryer Appendix D2 - v1.0.xlsx More Documents & Publications Water Heaters (Storage Oil) Metal Halide Lamp Ballast and Fixture Commercial Refrigeration Equipment...

  2. Treatment of exhaust fluorescent lamps to recover yttrium: Experimental and process analyses

    SciTech Connect (OSTI)

    De Michelis, Ida, E-mail: ida.demichelis@univaq.it [University of L'Aquila, Department of Chemistry, Chemical Engineering and Materials - Ex-Optimes Loc., Campo di Pile, 67100 L'Aquila (Italy); Ferella, Francesco, E-mail: francesco.ferella@univaq.it [University of L'Aquila, Department of Chemistry, Chemical Engineering and Materials - Ex-Optimes Loc., Campo di Pile, 67100 L'Aquila (Italy); Varelli, Ennio Fioravante [University of L'Aquila, Department of Chemistry, Chemical Engineering and Materials - Ex-Optimes Loc., Campo di Pile, 67100 L'Aquila (Italy); Veglio, Francesco, E-mail: francesco.veglio@univaq.it [University of L'Aquila, Department of Chemistry, Chemical Engineering and Materials - Ex-Optimes Loc., Campo di Pile, 67100 L'Aquila (Italy)

    2011-12-15T23:59:59.000Z

    Highlights: > Recovery of yttrium from spent fluorescent lamps by sulphuric acid leaching. > The use of sulphuric acid allows to reduce calcium dissolutions. > Main contaminant of fluorescent powder are Si, Pb, Ca and Ba. > Hydrated yttrium oxalate, recovered by selective precipitation, is quite pure (>90%). > We have studied the whole process for the treatment of dangerous waste (plant capability). - Abstract: The paper deals with recovery of yttrium from fluorescent powder coming from dismantling of spent fluorescent tubes. Metals are leached by using different acids (nitric, hydrochloric and sulphuric) and ammonia in different leaching tests. These tests show that ammonia is not suitable to recover yttrium, whereas HNO{sub 3} produces toxic vapours. A full factorial design is carried out with HCl and H{sub 2}SO{sub 4} to evaluate the influence of operating factors. HCl and H{sub 2}SO{sub 4} leaching systems give similar results in terms of yttrium extraction yield, but the last one allows to reduce calcium extraction with subsequent advantage during recovery of yttrium compounds in the downstream. The greatest extraction of yttrium is obtained by 20% w/v S/L ratio, 4 N H{sub 2}SO{sub 4} concentration and 90 deg. C. Yttrium and calcium yields are nearly 85% and 5%, respectively. The analysis of variance shows that acid concentration alone and interaction between acid and pulp density have a significant positive effect on yttrium solubilization for both HCl and H{sub 2}SO{sub 4} medium. Two models are empirically developed to estimate yttrium and calcium concentration during leaching. Precipitation tests demonstrate that at least the stoichiometric amount of oxalic acid is necessary to recover yttrium efficiently and a pure yttrium oxalate n-hydrate can be produced (99% grade). The process is economically feasible if other components of the fluorescent lamps (glass, ferrous and non-ferrous scraps) are recovered after the equipment dismantling and valorized, besides the cost that is usually paid to recycling companies for collection, treatment or final disposal of such fluorescent powders.

  3. CALiPER Report 20.1: Subjective Evaluation of Beam Quality, Shadow Quality, and Color Quality for LED PAR38 Lamps

    Broader source: Energy.gov [DOE]

    This December 3, 2013 webinar explored the findings of CALiPER 20.1: Subjective Evaluation of Beam Quality, Shadow Quality, and Color Quality for LED PAR38 Lamps and discussed what attributes to...

  4. Method and apparatus for mounting a dichroic mirror in a microwave powered lamp assembly using deformable tabs

    DOE Patents [OSTI]

    Ury, M.; Sowers, F.; Harper, C.; Love, W.

    1998-11-24T23:59:59.000Z

    A microwave powered electrodeless lamp includes an improved screen unit having mesh and solid sections with an internal reflector secured at the juncture of the two sections to reflect light into a light-transmitting chamber defined in the lamp microwave cavity by the reflector and the mesh section. A discharge envelope of a bulb is disposed in the light-transmitting chamber. Light emitted from the envelope is prevented by the reflector from entering the cavity portion bounded by the solid section of the screen. The reflector is mounted in the cavity by tabs formed in the screen unit and bendable into the cavity to define support planes abutting respective surfaces of the reflector. The mesh section and tabs are preferably formed by etching a thin metal sheet. 7 figs.

  5. Method and apparatus for mounting a dichroic mirror in a microwave powered lamp assembly using deformable tabs

    DOE Patents [OSTI]

    Ury, Michael (Bethesda, MD); Sowers, Frank (Frederick, MD); Harper, Curt (Wheaton, MD); Love, Wayne (Olney, MD)

    1998-01-01T23:59:59.000Z

    A microwave powered electrodeless lamp includes an improved screen unit having mesh and solid sections with an internal reflector secured at the juncture of the two sections to reflect light into a light-transmitting chamber defined in the lamp microwave cavity by the reflector and the mesh section. A discharge envelope of a bulb is disposed in the light-transmitting chamber. Light emitted from the envelope is prevented by the reflector from entering the cavity portion bounded by the solid section of the screen. The reflector is mounted in the cavity by tabs formed in the screen unit and bendable into the cavity to define support planes abutting respective surfaces of the reflector. The mesh section and tabs are preferably formed by etching a thin metal sheet.

  6. Color stable phosphors for LED lamps and methods for preparing them

    DOE Patents [OSTI]

    Murphy, James Edward; Setlur, Anant Achyut; Camardello, Samuel Joseph

    2013-11-26T23:59:59.000Z

    An LED lamp includes a light source configured to emit radiation with a peak intensity at a wavelength between about 250 nm and about 550 nm; and a phosphor composition configured to be radiationally coupled to the light source. The phosphor composition includes particles of a phosphor of formula I, said particles having a coating composition disposed on surfaces thereof; ((Sr.sub.1-zM.sub.z).sub.1-(x+w)A.sub.wCe.sub.x).sub.3(Al.sub.1-ySi.sub.y-)O.sub.4+y+3(x-w)F.sub.1-y-3(x-w) I wherein the coating composition comprises a material selected from aluminum oxide, magnesium oxide, calcium oxide, barium oxide, strontium oxide, zinc oxide, aluminum hydroxide, magnesium hydroxide, calcium hydroxide, barium hydroxide, strontium hydroxide, zinc hydroxide, aluminum phosphate, magnesium phosphate, calcium phosphate, barium phosphate, strontium phosphate, and combinations thereof; and A is Li, NA, K, or Rb, or a combination thereof; M is Ca, Ba, Mg, Zn, or a combination thereof; and 0

  7. Data:5f4a0f12-fe92-4a3d-ab4c-d7fd2b5872ba | Open Energy Information

    Open Energy Info (EERE)

    on PUD-owned poles. Maintenance by the PUD includes lamp, photo cell and fixture replacement as needed. Individual lamps will be replaced on burnout as soon as reasonably...

  8. Data:80545bfb-07c5-460a-8c4e-7e636f22ff83 | Open Energy Information

    Open Energy Info (EERE)

    on PUD-owned poles. Maintenance by the PUD includes lamp, photo cell and fixture replacement as needed. Individual lamps will be replaced on burnout as soon as reasonably...

  9. Data:95957a4b-7e2b-41fe-a642-51703e1fc5fa | Open Energy Information

    Open Energy Info (EERE)

    on PUD-owned poles. Maintenance by the PUD includes lamp, photo cell and fixture replacement as needed. Individual lamps will be replaced on burnout as soon as reasonably...

  10. Data:1a8d6ca0-0e6e-484a-a960-41e34138aa76 | Open Energy Information

    Open Energy Info (EERE)

    on PUD-owned poles. Maintenance by the PUD includes lamp, photo cell and fixture replacement as needed. Individual lamps will be replaced on burnout as soon as reasonably...

  11. Data:1a84a6ea-bfe8-403c-8f22-c85e8a48f3c3 | Open Energy Information

    Open Energy Info (EERE)

    on PUD-owned poles. Maintenance by the PUD includes lamp, photo cell and fixture replacement as needed. Individual lamps will be replaced on burnout as soon as reasonably...

  12. Data:56e44dc6-465e-4aae-af68-4af7ee096040 | Open Energy Information

    Open Energy Info (EERE)

    on PUD-owned poles. Maintenance by the PUD includes lamp, photo cell and fixture replacement as needed. Individual lamps will be replaced on burnout as soon as reasonably...

  13. Data:Ea602702-2777-4ed7-a00e-c41af30caa64 | Open Energy Information

    Open Energy Info (EERE)

    on PUD-owned poles. Maintenance by the PUD includes lamp, photo cell and fixture replacement as needed. Individual lamps will be replaced on burnout as soon as reasonably...

  14. Data:4d4a3bb2-d0d6-4d47-8afa-7003bd06f9b9 | Open Energy Information

    Open Energy Info (EERE)

    on PUD-owned poles. Maintenance by the PUD includes lamp, photo cell and fixture replacement as needed. Individual lamps will be replaced on burnout as soon as reasonably...

  15. Data:8dfc12b7-8f92-41cf-ae09-58d9cb37a86b | Open Energy Information

    Open Energy Info (EERE)

    on PUD-owned poles. Maintenance by the PUD includes lamp, photo cell and fixture replacement as needed. Individual lamps will be replaced on burnout as soon as reasonably...

  16. Data:81d91b19-1a87-4a5b-8715-5651a041a938 | Open Energy Information

    Open Energy Info (EERE)

    on PUD-owned poles. Maintenance by the PUD includes lamp, photo cell and fixture replacement as needed. Individual lamps will be replaced on burnout as soon as reasonably...

  17. Demand Forecast Advisory Committee in Preparation for the Seventh Power Plan

    E-Print Network [OSTI]

    products, electric motors, commercial water heaters, and heating, ventilation, and air conditioning Water Heaters and Unfired Water Heater Tanks Compact Fluorescent Lamps Dehumidifiers Direct heating Washers Commercial Ice Makers Metal Halide Lamps Fixtures Pool heaters Commercial Ice Makers

  18. CALIFORNIA Jackalyne Pfannenstiel

    E-Print Network [OSTI]

    Efficiency Regulations, appliance standards, refrigerators, air conditioners, space heaters, water heaters, pool heaters, plumbing fittings, plumbing fixtures, showerheads, spray valves, faucets, tub spout diverters, water closets, urinals, fluorescent lamp ballasts, lamps, emergency lighting, exit signs, traffic

  19. An Assessment of the U.S. Residential Lighting Market

    SciTech Connect (OSTI)

    Jennings, Judy; Brown, Rich; Moezzi, Mithra; Mills, Evan; Sardinsky, Robert

    1995-10-01T23:59:59.000Z

    This report provides background data upon which residential lighting fixture energy conservation programs can be built. The current stock of residential lighting is described by usage level, lamp wattage, fixture type, and location within the house. Data are discussed that indicate that 25% of residential fixtures are responsible for 80% of residential lighting energy use, and that justify targeting these fixtures as candidates for retrofit with energy-efficient fixtures. Fixtures determined to have the highest energy use are hardwired ceiling fixtures in kitchens, living/family rooms, dining rooms, and outdoors. An assessment of the market for residential fixtures shows that nearly half of new residential fixtures are imported, 61% of new fixtures sold are hardwired, and about half of all new fixtures sold are for ceiling installation.

  20. Conference shapes direction of Doctrine 2015 -Fort Leavenworth, KS -The Fort Leavenworth Lamp http://www.ftleavenworthlamp.com/news/around_the_force/x27456959/Conference-shapes-direction-of-Doctrine-2015[8/18/2011 12:32:27 PM

    E-Print Network [OSTI]

    US Army Corps of Engineers

    Conference shapes direction of Doctrine 2015 - Fort Leavenworth, KS - The Fort Leavenworth Lamp and more accessible. The conference was led by the Combined Arms Doctrine Directorate, a subordinate

  1. Fusion bonding and alignment fixture

    DOE Patents [OSTI]

    Ackler, Harold D. (Sunnyvale, CA); Swierkowski, Stefan P. (Livermore, CA); Tarte, Lisa A. (Livermore, CA); Hicks, Randall K. (Stockton, CA)

    2000-01-01T23:59:59.000Z

    An improved vacuum fusion bonding structure and process for aligned bonding of large area glass plates, patterned with microchannels and access holes and slots, for elevated glass fusion temperatures. Vacuum pumpout of all the components is through the bottom platform which yields an untouched, defect free top surface which greatly improves optical access through this smooth surface. Also, a completely non-adherent interlayer, such as graphite, with alignment and location features is located between the main steel platform and the glass plate pair, which makes large improvements in quality, yield, and ease of use, and enables aligned bonding of very large glass structures.

  2. Sample push-out fixture

    DOE Patents [OSTI]

    Biernat, John L. (Scotia, NY)

    2002-11-05T23:59:59.000Z

    This invention generally relates to the remote removal of pelletized samples from cylindrical containment capsules. V-blocks are used to receive the samples and provide guidance to push out rods. Stainless steel liners fit into the v-channels on the v-blocks which permits them to be remotely removed and replaced or cleaned to prevent cross contamination between capsules and samples. A capsule holder securely holds the capsule while allowing manual up/down and in/out movement to align each sample hole with the v-blocks. Both end sections contain identical v-blocks; one that guides the drive out screw and rods or manual push out rods and the other to receive the samples as they are driven out of the capsule.

  3. 2014-06-18 Issuance: Test Procedure for Integrated Light-Emitting Diode Lamps; Supplemental Notice of Proposed Rulemaking

    Broader source: Energy.gov [DOE]

    This document is a pre-publication Federal Register Supplemental Notice of Proposed Rulemaking regarding Test Procedures for Integrated Light-Emitting Diode Lamps, as issued by the Deputy Assistant Secretary for Energy Efficiency on June 18, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

  4. The Spectrum of the Th-Ar Hollow-Cathode Lamp Used with the 2dcoude Spectrograph

    E-Print Network [OSTI]

    Carlos Allende Prieto

    2001-11-08T23:59:59.000Z

    We have produced an atlas of the Th-Ar hollow-cathode lamp used with the 2dcoude spectrograph at McDonald Observatory. The atlas covers from 3611.9 to 10596.4 A at a resolving power of 52,000. We have determined the wavelenghts of 1483 emission lines in the spectrum with a median precision of 0.00023 A. A web-based interface is offered for interactive visualization of segments of the atlas or spectral orders.

  5. Influence of the chlorine concentration on the radiation efficiency of a XeCl exciplex lamp

    SciTech Connect (OSTI)

    Avtaeva, S. V., E-mail: s_avtaeva@mail.ru [Kyrgyz-Russian Slavic University (Kyrgyzstan); Sosnin, E. A. [Russian Academy of Sciences, Institute of High-Current Electronics, Siberian Branch (Russian Federation)] [Russian Academy of Sciences, Institute of High-Current Electronics, Siberian Branch (Russian Federation); Saghi, B. [Mohamed Boudiaf University of Sciences and Technology, Department of Electronics (Algeria)] [Mohamed Boudiaf University of Sciences and Technology, Department of Electronics (Algeria); Panarin, V. A. [Russian Academy of Sciences, Institute of High-Current Electronics, Siberian Branch (Russian Federation)] [Russian Academy of Sciences, Institute of High-Current Electronics, Siberian Branch (Russian Federation); Rahmani, B. [Mohamed Boudiaf University of Sciences and Technology, Department of Electronics (Algeria)] [Mohamed Boudiaf University of Sciences and Technology, Department of Electronics (Algeria)

    2013-09-15T23:59:59.000Z

    The influence of the chlorine concentration on the radiation efficiency of coaxial exciplex lamps (excilamps) excited by a dielectric barrier discharge (DBD) in binary Xe-Cl{sub 2} mixtures at pressures of 240–250 Torr is investigated experimentally and theoretically. The experiments were carried out at Cl{sub 2} concentrations in the range of 0.01–1%. The DBD characteristics were calculated in the framework of a one-dimensional hydrodynamic model at Cl{sub 2} concentrations in the range of 0.1–5%. It is found that the radiation intensities of the emission bands of Xe*{sub 2}(172 nm) and XeCl* (308 nm) are comparable when the chlorine concentration in the mixture is in the range of 0.01–0.1%. In this case, in the mixture, the radiation intensity of the Xe*{sub 2} molecule rapidly decreases with increasing Cl{sub 2} concentration and, at a chlorine concentration of ?0.2%, the radiation of the B ? X band of XeCl* molecules with a peak at 308 nm dominates in the discharge radiation. The radiation efficiency of this band reaches its maximum value at chlorine concentrations in the range of 0.4–0.5%. The calculated efficiencies of DBD radiation exceed those obtained experimentally. This is due to limitations of the one-dimensional model, which assumes the discharge to be uniform in the transverse direction, whereas the actual excilamp discharge is highly inhomogeneous. The influence of the chlorine concentration on the properties of the DBD plasma in binary Xe-Cl{sub 2} mixtures is studied numerically. It is shown that an increase in the Cl{sub 2} concentration in the mixture leads to the attachment of electrons to chlorine atoms and a decrease in the electron density and discharge conductivity. As a result, the electric field and the voltage drop across the discharge gap increase, which, in turn, leads to an increase in the average electron energy and the probability of dissociation of Cl{sub 2} molecules and ionization of Xe atoms and Cl{sub 2} molecules. The total energy deposited in the discharge rises with increasing chlorine concentration due to an increase in the power spent on the heating of positive and negative ions. The power dissipated by electrons decreases with increasing chlorine concentration in the working mixture. Recommendations on the choice of the chlorine content in the mixture for reducing the intensity of VUV radiation of the second continuum of the Xe*{sub 2} excimer without a substantial decrease in the excilamp efficiency are formulated.

  6. Evaluation of a single cell and candidate materials with high water content hydrogen in a generic solid oxide fuel cell stack test fixture, Part II: materials and interface characterization

    SciTech Connect (OSTI)

    Chou, Y. S.; Stevenson, Jeffry W.; Choi, Jung-Pyung

    2013-01-01T23:59:59.000Z

    A generic solid oxide fuel cell (SOFC) test fixture was developed to evaluate candidate materials under realistic conditions. A commerical 50 mm x 50 mm NiO-YSZ anode supported thin YSZ electrolyte cell with lanthanum strontium manganite (LSM) cathode was tested to evaluate the stability of candidate materials. The cell was tested in two stages at 800oC: stage I of low (~3% H2O) humidity and stage II of high (~30% H2O) humidity hydrogen fuel at constant voltage or constant current mode. Part I of the work was published earlier with information of the generic test fixture design, materials, cell performance, and optical post-mortem analysis. In part II, detailed microstructure and interfacial characterizations are reported regarding the SOFC candidate materials: (Mn,Co)-spinel conductive coating, alumina coating for sealing area, ferritic stainless steel interconnect, refractory sealing glass, and their interactions with each other. Overall, the (Mn,Co)-spinel coating was very effective in minimizing Cr migration. No Cr was identified in the cathode after 1720h at 800oC. Aluminization of metallic interconnect also proved to be chemically compatible with alkaline-earth silicate sealing glass. The details of interfacial reaction and microstructure development are discussed.

  7. Overview of the Rebuild America Program in Texas 

    E-Print Network [OSTI]

    Saman, N.; Haberl, J. S.; Turner, W. D.

    1998-01-01T23:59:59.000Z

    storage. Medical air scheduling, modify EMS controls. Install EMS systems, DDC EMS conversion, replace EMS. Control room temperature via EMS, repair and reactivate EMS. connect . - HI: Controls I individual rooftop unih, convert HVAC unih to central... . - . , - . . > . . . ballasts, use high eff~cien ballasts and lamps. L4: Exit signs I Replace exit light fixtures, energy elficient exit lights. change exit lights to LZ: Fixture changdreflectors L3: Uoerade photocells. Replaedremove lamps/Fixtures, convert incandescent...

  8. DOE Publishes CALiPER Report on Linear (T8) LED Lamps in a 2x4 K12-Lensed Troffer

    Broader source: Energy.gov [DOE]

    The U.S. Department of Energy's CALiPER program has released Report 21.1, which is part of a series of investigations on linear LED lamps. Report 21.1 focuses on the performance of 31 types of...

  9. Mechanistic Evaluation of the Pros and Cons of Digital RT-LAMP for HIV1 Viral Load Quantification on a Microfluidic Device and

    E-Print Network [OSTI]

    Ismagilov, Rustem F.

    to manipulate many single molecules in parallel through a two-step digital process. In the first step weMechanistic Evaluation of the Pros and Cons of Digital RT-LAMP for HIV1 Viral Load Quantification on a Microfluidic Device and Improved Efficiency via a Two-Step Digital Protocol Bing Sun, Feng Shen, Stephanie E

  10. * Corresponding author. Tel.: #44-1570-424736. E-mail address: walker@lamp.ac.uk (M.J.C. Walker)

    E-Print Network [OSTI]

    Wohlfarth, Barbara

    * Corresponding author. Tel.: #44-1570-424736. E-mail address: walker@lamp.ac.uk (M.J.C. Walker that these approaches were never designed for such "ne-scale resolution of the strati- graphic record. This has led

  11. Facilitating RFID Development with the Accada Prototyping Platform Christian Floerkemeier, Matthias Lampe, and Christof Roduner

    E-Print Network [OSTI]

    an IT infrastructure that provides RFID de- vice and data management and supports application devel- opment by significantly lowering the barrier for large-scale, real-world testing. 1 Introduction Radio Frequency.3454656 by reader 8745653 would thus result in the corresponding busi- ness event that a shipment of razor blades

  12. DOE CALiPER Program, Report 20.1 Subjective Evaluation of Beam Quality, Shadow Quality, and Color Quality for LED PAR38 Lamps

    SciTech Connect (OSTI)

    Royer, Michael P.; Poplawski, Michael E.; Miller, Naomi J.

    2013-10-01T23:59:59.000Z

    This report focuses on human-evaluated characteristics, including beam quality, shadow quality, and color quality. Using a questionnaire that included rank ordering, opinions on 27 of the Report 20 PAR38 lamps were gathered during a demonstration event for members of the local Illuminating Engineering Society (IES) chapter. This was not a rigorous scientific experiment, and the data should not be extrapolated beyond the scope of the demonstration. The results suggest that many of the LED products compared favorably to halogen PAR38 benchmarks in all attributes considered. LED lamps using a single-emitter design were generally preferred for their beam quality and shadow quality, and the IES members ranking of color quality did not always match the rank according to the color rendering index (CRI).

  13. NIST energy related inventions - electronic starter device for fluorescent lamps. Final report

    SciTech Connect (OSTI)

    NONE

    1998-06-01T23:59:59.000Z

    Due to silicon supplier failures to produce the 03/04 triac silicon as specified in the original proposal, the direction of the starter program was migrated to use available off the shelf power semiconductors. This had unexpected positive side effects including a reduction in component price, improved quality, and the refocus of engineering efforts to concentrate on the Super ASIC core technology. The starter program has begun shipments employing this new architecture, and is being well received both in the US and abroad. In its present form, the starter meets the original cost projections within 20%. Work is continuing on the 0.8 micron ASIC, which will allow for the starter to sell below $1.00 in volume. Even at the slightly higher price, interest is strong in replacing the low performance glow starter for small fluorescent applications with a high performance alternative.

  14. Many exterior entry lights in residential and commercial applications use two-

    E-Print Network [OSTI]

    , and replacement CFLs are not widely stocked. The Light-Emitting Diode (LED) Hybrid Security Fixture combines

  15. The Carbon-Land Model Intercomparison Project (C-LAMP): A Model-Data Comparison System for Evaluation of Coupled Biosphere-Atmosphere Models

    SciTech Connect (OSTI)

    Hoffman, Forrest M [ORNL; Randerson, Jim [University of California, Irvine; Thornton, Peter E [ORNL; Mahowald, Natalie [Cornell University; Bonan, Gordon [National Center for Atmospheric Research (NCAR); Running, Steven [University of Montana, Missoula; Fung, Inez [University of California, Berkeley

    2009-01-01T23:59:59.000Z

    The need to capture important climate feebacks in general circulation models (GCMs) has resulted in new efforts to include atmospheric chemistry and land and ocean biogeochemistry into the next generation of production climate models, now often referred to as Earth System Models (ESMs). While many terrestrial and ocean carbon models have been coupled to GCMs, recent work has shown that such models can yield a wide range of results, suggesting that a more rigorous set of offline and partially coupled experiments, along with detailed analyses of processes and comparisons with measurements, are warranted. The Carbon-Land Model Intercomparison Project (C-LAMP) provides a simulation protocol and model performance metrics based upon comparisons against best-available satellite- and ground-based measurements (Hoffman et al., 2007). C-LAMP provides feedback to the modeling community regarding model improvements and to the measurement community by suggesting new observational campaigns. C-LAMP Experiment 1 consists of a set of uncoupled simulations of terrestrial carbon models specifically designed to examine the ability of the models to reproduce surface carbon and energy fluxes at multiple sites and to exhibit the influence of climate variability, prescribed atmospheric carbon dioxide (CO{sub 2}), nitrogen (N) deposition, and land cover change on projections of terrestrial carbon fluxes during the 20th century. Experiment 2 consists of partially coupled simulations of the terrestrial carbon model with an active atmosphere model exchanging energy and moisture fluxes. In all experiments, atmospheric CO{sub 2} follows the prescribed historical trajectory from C{sup 4}MIP. In Experiment 2, the atmosphere model is forced with prescribed sea surface temperatures (SSTs) and corresponding sea ice concentrations from the Hadley Centre; prescribed CO{sub 2} is radiatively active; and land, fossil fuel, and ocean CO{sub 2} fluxes are advected by the model. Both sets of experiments have been performed using two different terrestrial biogeochemistry modules coupled to the Community Land Model version 3 (CLM3) in the Community Climate System Model version 3 (CCSM3): The CASA model of Fung, et al., and the carbon-nitrogen (CN) model of Thornton. Comparisons against Ameriflus site measurements, MODIS satellite observations, NOAA flask records, TRANSCOM inversions, and Free Air CO{sub 2} Enrichment (FACE) site measurements, and other datasets have been performed and are described in Randerson et al. (2009). The C-LAMP diagnostics package was used to validate improvements to CASA and CN for use in the next generation model, CLM4. It is hoped that this effort will serve as a prototype for an international carbon-cycle model benchmarking activity for models being used for the Inter-governmental Panel on Climate Change (IPCC) Fifth Assessment Report. More information about C-LAMP, the experimental protocol, performance metrics, output standards, and model-data comparisons from the CLM3-CASA and CLM3-CN models are available at http://www.climatemodeling.org/c-lamp.

  16. Assessing the Performance of 5mm White LED Light Sources for Developing-Country Applications

    E-Print Network [OSTI]

    Mills, Evan

    2007-01-01T23:59:59.000Z

    lamp calibrated by Labsphere Spectral measurements - LEDs inLEDs we tested is exceptionally good (as good or better than many compact fluorescent lamps),lamp. Off-grid lighting products using the poorer LEDs would

  17. Phosphors for LED lamps

    DOE Patents [OSTI]

    Murphy, James Edward; Manepalli, Satya Kishore; Kumar, Prasanth Nammalwar

    2013-08-13T23:59:59.000Z

    A phosphor, a phosphor blend including the phosphor, a phosphor prepared by a process, and a lighting apparatus including the phosphor blend are disclosed. The phosphor has the formula (Ca.sub.1-p-qCe.sub.pK.sub.q).sub.xSc.sub.y(Si.sub.1-rGa.sub.r).sub.zO.su- b.12+.delta. or derived from a process followed using disclosed amounts of reactants. In the formula, (0

  18. Cost-effective Lighting Retrofits: Lessons Learned

    E-Print Network [OSTI]

    Fisher, M. D.

    1994-01-01T23:59:59.000Z

    in cramped fixtures. Those who replace lamps are often more likely to replace failed integral units with cheap incandescents again, while with component-type units they tend to replace the failed fluorescent lamp only. - Where incandescent lamps are on a... fixtures, 9 and 13 watt quad tubes may not start in freezing weather. Twin 9be lamps of similar wattages may be a better ioice. Power factor can be quite low on some lagnetic ballasted products, while total ~rmonic distortion can be high on some...

  19. Application APPLICATION

    E-Print Network [OSTI]

    Papautsky, Ian

    in the CCM Bulletin which can be downloaded from ccm.uc.edu/admissions/ application. You will automatically be considered for a talent-based scholarship when you audition/ interview for entrance into CCM. These awards would also like to invite you to tour CCM's excellent facilities and observe some classes and ensemble

  20. CX-007916: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Notice of Proposed Rulemaking for( Energy Conservation Standards for Metal Halide lamp Fixtures CX(s) Applied: B5.1 Date: 01/04/2012 Location(s): Nationwide Offices(s): Energy Efficiency and Renewable Energy

  1. CX-011776: Categorical Exclusion Determination | Department of...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    CX-011776: Categorical Exclusion Determination Final Rule for New and Amended Energy Conservation Standards for Metal Halide Lamp Fixtures CX(s) Applied: B5.1 Date: 01292014...

  2. Data:0ac74409-f2ac-4fb5-89ca-2b93352f3c66 | Open Energy Information

    Open Energy Info (EERE)

    date: 20110315 End date if known: Rate name: MU-1 - a1b - 1000 watt MV Sector: Lighting Description: Lamps in enclosed fixtures, mounted on metal or fiberglass columns and...

  3. Data:F41f2063-da07-414c-8c6b-431dcdae21a1 | Open Energy Information

    Open Energy Info (EERE)

    0315 End date if known: Rate name: MU-1 - a1b - 400 watt MH - Metal Column Sector: Lighting Description: Lamps in enclosed fixtures, mounted on metal or fiberglass columns and...

  4. Data:36db4f81-4ebf-4936-9d7e-3d72e0723c22 | Open Energy Information

    Open Energy Info (EERE)

    End date if known: Rate name: MU-1 - a1b - 250 watt HPS - Bronze Traffic Pole Sector: Lighting Description: Lamps in enclosed fixtures, mounted on metal or fiberglass columns and...

  5. Data:1608f1e2-f9fa-4f97-a612-b97eb4d202d0 | Open Energy Information

    Open Energy Info (EERE)

    20110315 End date if known: Rate name: MU-1 - a1b - 2-400 watt MH - Shoebox Sector: Lighting Description: Lamps in enclosed fixtures, mounted on metal or fiberglass columns and...

  6. Data:6e5ad8c9-7149-413c-8111-772ba068de0f | Open Energy Information

    Open Energy Info (EERE)

    0315 End date if known: Rate name: MU-1 - a1b - 250 watt HPS - Fiberglass Sector: Lighting Description: Lamps in enclosed fixtures, mounted on metal or fiberglass columns and...

  7. Data:A193f29f-3d8f-4722-b411-17e0d8406bb2 | Open Energy Information

    Open Energy Info (EERE)

    End date if known: Rate name: MU-1 - a1c - 175 watt MV - Washington Post Std. Sector: Lighting Description: Lamps in enclosed post top type fixtures, mounted on metal or fiberglass...

  8. Data:Def61fa4-3ad9-42f2-89e9-f09fbbbeff8f | Open Energy Information

    Open Energy Info (EERE)

    date: 20110315 End date if known: Rate name: MU-1 - a1a - 175 watt MV Sector: Lighting Description: Lamps in enclosed fixtures, suspended from mast arms on wood poles and...

  9. Data:A566f5df-b2c7-4412-b54f-59d9dfe7e16b | Open Energy Information

    Open Energy Info (EERE)

    0315 End date if known: Rate name: MU-1 - a1b - 2-400 watt HPS - Shoebox Sector: Lighting Description: Lamps in enclosed fixtures, mounted on metal or fiberglass columns and...

  10. Data:3ebaec5b-7b13-4af4-a721-a2f58283b0a8 | Open Energy Information

    Open Energy Info (EERE)

    15 End date if known: Rate name: MU-1 - a1c - 3-150 watt HPS - Twin Column Sector: Lighting Description: Lamps in enclosed post top type fixtures, mounted on metal or fiberglass...

  11. Data:0bd66cfb-dc2f-4c39-a60a-d02a1621e89f | Open Energy Information

    Open Energy Info (EERE)

    date: 20110315 End date if known: Rate name: MU-1 - a1b - 175 watt MV Sector: Lighting Description: Lamps in enclosed fixtures, mounted on metal or fiberglass columns and...

  12. Data:F8ee66b6-036d-4c9c-87a2-6159b1760029 | Open Energy Information

    Open Energy Info (EERE)

    if known: Rate name: MU-1 - a1c - 1-150 watt HPS & 4-100 watt HPS - Cluster Sector: Lighting Description: Lamps in enclosed post top type fixtures, mounted on metal or fiberglass...

  13. Data:2af370e7-3939-4dfc-b1ad-7bd653e07e25 | Open Energy Information

    Open Energy Info (EERE)

    0315 End date if known: Rate name: MU-1 - a1c - 5-150 watt HPS - Cluster Sector: Lighting Description: Lamps in enclosed post top type fixtures, mounted on metal or fiberglass...

  14. Data:7089c752-0aea-4075-b3f9-64a1c94d673a | Open Energy Information

    Open Energy Info (EERE)

    if known: Rate name: MU-1 - a1c - 150 watt HPS - 18" Ball Globe Post Std. Sector: Lighting Description: Lamps in enclosed post top type fixtures, mounted on metal or fiberglass...

  15. Data:53c9a897-96ef-4b74-b1cf-06c0d7f9fc42 | Open Energy Information

    Open Energy Info (EERE)

    0315 End date if known: Rate name: MU-1 - a1b - 150 watt HPS - Fiberglass Sector: Lighting Description: Lamps in enclosed fixtures, mounted on metal or fiberglass columns and...

  16. Data:825c2504-3839-49bf-aaf9-aa6655741203 | Open Energy Information

    Open Energy Info (EERE)

    date: 20110315 End date if known: Rate name: MU-1 - a1a - 150 watt HPS Sector: Lighting Description: Lamps in enclosed fixtures, suspended from mast arms on wood poles and...

  17. Data:1a3263cc-9b87-4114-9f8a-57270e64790f | Open Energy Information

    Open Energy Info (EERE)

    date if known: Rate name: MU-1 - a1b - 400 watt HPS - Painted Bronze Column Sector: Lighting Description: Lamps in enclosed fixtures, mounted on metal or fiberglass columns and...

  18. Data:3dee116c-33c8-4d0b-b7d5-3fa0f6a584eb | Open Energy Information

    Open Energy Info (EERE)

    date: 20110315 End date if known: Rate name: MU-1 - a1a - 400 watt MV Sector: Lighting Description: Lamps in enclosed fixtures, suspended from mast arms on wood poles and...

  19. Data:01e247e8-be67-4602-8694-51e1a78c6bbb | Open Energy Information

    Open Energy Info (EERE)

    15 End date if known: Rate name: MU-1 - a1c - 3-150 watt HPS - Single Column Sector: Lighting Description: Lamps in enclosed post top type fixtures, mounted on metal or fiberglass...

  20. Data:7cd89c27-8ade-4bc0-a082-f9c9dd50a849 | Open Energy Information

    Open Energy Info (EERE)

    0315 End date if known: Rate name: MU-1 - a1b - 2-250 watt HPS - Shoebox Sector: Lighting Description: Lamps in enclosed fixtures, mounted on metal or fiberglass columns and...

  1. Data:Fbd47a8e-f9b3-4e70-ac19-ae2a035f5fce | Open Energy Information

    Open Energy Info (EERE)

    20110315 End date if known: Rate name: MU-1 - a1b - 250 watt HPS - Shoebox Sector: Lighting Description: Lamps in enclosed fixtures, mounted on metal or fiberglass columns and...

  2. Data:40d2b8fd-74c0-4db9-b319-bdaeecc6863f | Open Energy Information

    Open Energy Info (EERE)

    0315 End date if known: Rate name: MU-1 - a1c - 100 watt HPS - Post Std. Sector: Lighting Description: Lamps in enclosed post top type fixtures, mounted on metal or fiberglass...

  3. Data:Ccfea250-ea35-4086-9df5-32c636b25a96 | Open Energy Information

    Open Energy Info (EERE)

    20110315 End date if known: Rate name: MU-1 - a1b - 400 watt HPS - Shoebox Sector: Lighting Description: Lamps in enclosed fixtures, mounted on metal or fiberglass columns and...

  4. Data:Bed43de6-1013-4ad2-b40b-68cf5a45e541 | Open Energy Information

    Open Energy Info (EERE)

    date if known: Rate name: MU-1 - a1c - 150 watt HPS - Washington Post Std. Sector: Lighting Description: Lamps in enclosed post top type fixtures, mounted on metal or fiberglass...

  5. Data:Cc155446-240b-45ef-ab27-7755ecb9857c | Open Energy Information

    Open Energy Info (EERE)

    date: 20110315 End date if known: Rate name: MU-1 - a1a - 400 watt HPS Sector: Lighting Description: Lamps in enclosed fixtures, suspended from mast arms on wood poles and...

  6. Data:C8ac9d75-7034-4a87-8a87-95c56d6c3d03 | Open Energy Information

    Open Energy Info (EERE)

    date: 20110315 End date if known: Rate name: MU-1 - a1b - 250 watt HPS Sector: Lighting Description: Lamps in enclosed fixtures, mounted on metal or fiberglass columns and...

  7. Data:047e251d-9127-499d-bb69-3404eb7afda5 | Open Energy Information

    Open Energy Info (EERE)

    date: 20110315 End date if known: Rate name: MU-1 - a1a - 250 watt HPS Sector: Lighting Description: Lamps in enclosed fixtures, suspended from mast arms on wood poles and...

  8. Data:41c9ad0e-41ac-4e01-bb3f-083e704d7b0a | Open Energy Information

    Open Energy Info (EERE)

    End date if known: Rate name: MU-1 - a1b - 400 watt HPS - Bronze Traffic Pole Sector: Lighting Description: Lamps in enclosed fixtures, mounted on metal or fiberglass columns and...

  9. Data:75bb6a1f-68d3-4f8a-ba67-535081078b0b | Open Energy Information

    Open Energy Info (EERE)

    0315 End date if known: Rate name: MU-1 - a1b - 100 watt HPS - Fiberglass Sector: Lighting Description: Lamps in enclosed fixtures, mounted on metal or fiberglass columns and...

  10. Data:A340ac6e-351a-41dc-ba1a-991cf2075f71 | Open Energy Information

    Open Energy Info (EERE)

    0315 End date if known: Rate name: MU-1 - a1b - 175 watt MV - Fiberglass Sector: Lighting Description: Lamps in enclosed fixtures, mounted on metal or fiberglass columns and...

  11. Data:E61cae69-960f-41d6-9622-75bdeef41091 | Open Energy Information

    Open Energy Info (EERE)

    date if known: Rate name: MU-1 - a1c - 2-80 watt LED - Washington Post Std. Sector: Lighting Description: Lamps in enclosed post top type fixtures, mounted on metal or fiberglass...

  12. Data:0845c2ce-c94c-4de7-8692-99c1f66ed1c4 | Open Energy Information

    Open Energy Info (EERE)

    date: 20110315 End date if known: Rate name: MU-1 - a1b - 400 watt HPS Sector: Lighting Description: Lamps in enclosed fixtures, mounted on metal or fiberglass columns and...

  13. Data:9b7c1ef3-263e-43a3-af18-a202350a5cfc | Open Energy Information

    Open Energy Info (EERE)

    date: 20110315 End date if known: Rate name: MU-1 - a1a - 1000 watt MV Sector: Lighting Description: Lamps in enclosed fixtures, suspended from mast arms on wood poles and...

  14. Data:Fd797889-4f39-4b7c-97ee-fbb08ea5f625 | Open Energy Information

    Open Energy Info (EERE)

    20110315 End date if known: Rate name: MU-1 - a1b - 400 watt MH - Shoebox Sector: Lighting Description: Lamps in enclosed fixtures, mounted on metal or fiberglass columns and...

  15. Data:A2668659-a8ce-4f0d-b299-ca08f4421f85 | Open Energy Information

    Open Energy Info (EERE)

    date: 20110315 End date if known: Rate name: MU-1 - a1b - 400 watt MV Sector: Lighting Description: Lamps in enclosed fixtures, mounted on metal or fiberglass columns and...

  16. Data:0f468f93-07aa-4fdb-8b0b-b90559f5cad4 | Open Energy Information

    Open Energy Info (EERE)

    date: 20110315 End date if known: Rate name: MU-1 - a1b - 100 watt HPS Sector: Lighting Description: Lamps in enclosed fixtures, mounted on metal or fiberglass columns and...

  17. Data:4158f638-5823-497f-80b8-ce98e01cc236 | Open Energy Information

    Open Energy Info (EERE)

    date if known: Rate name: MU-1 - a1c - 100 watt HPS - Washington Post Std. Sector: Lighting Description: Lamps in enclosed post top type fixtures, mounted on metal or fiberglass...

  18. Data:2fb0f185-fe3e-4fb5-bdaa-5c647d5a18c5 | Open Energy Information

    Open Energy Info (EERE)

    date if known: Rate name: MU-1 - a1b - 250 watt HPS - Painted Bronze Column Sector: Lighting Description: Lamps in enclosed fixtures, mounted on metal or fiberglass columns and...

  19. Data:E2aba210-1563-4089-adf7-397f409d0477 | Open Energy Information

    Open Energy Info (EERE)

    date: 20110315 End date if known: Rate name: MU-1 - a1a - 100 watt HPS Sector: Lighting Description: Lamps in enclosed fixtures, suspended from mast arms on wood poles and...

  20. Data:64c3b345-b7a4-4ab0-a758-94b561711b43 | Open Energy Information

    Open Energy Info (EERE)

    date: 20110315 End date if known: Rate name: MU-1 - a1b - 150 watt HPS Sector: Lighting Description: Lamps in enclosed fixtures, mounted on metal or fiberglass columns and...

  1. Thorium, uranium and rare earth elements content in lanthanide concentrate (LC) and water leach purification (WLP) residue of Lynas advanced materials plant (LAMP)

    SciTech Connect (OSTI)

    AL-Areqi, Wadeeah M., E-mail: walareqi@yahoo.com; Majid, Amran Ab., E-mail: walareqi@yahoo.com; Sarmani, Sukiman, E-mail: walareqi@yahoo.com [Nuclear Science Programme, School of Chemical Sciences and Food Technology, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 Bangi (Malaysia)

    2014-02-12T23:59:59.000Z

    Lynas Advanced Materials Plant (LAMP) has been licensed to produce the rare earths elements since early 2013 in Malaysia. LAMP processes lanthanide concentrate (LC) to extract rare earth elements and subsequently produce large volumes of water leach purification (WLP) residue containing naturally occurring radioactive material (NORM). This residue has been rising up the environmental issue because it was suspected to accumulate thorium with significant activity concentration and has been classified as radioactive residue. The aim of this study is to determine Th-232, U-238 and rare earth elements in lanthanide concentrate (LC) and water leach purification (WLP) residue collected from LAMP and to evaluate the potential radiological impacts of the WLP residue on the environment. Instrumental Neutron Activation Analysis and ?-spectrometry were used for determination of Th, U and rare earth elements concentrations. The results of this study found that the concentration of Th in LC was 1289.7 ± 129 ppm (5274.9 ± 527.6Bq/kg) whereas the Th and U concentrations in WLP were determined to be 1952.9±17.6 ppm (7987.4 ± 71.9 Bq/kg) and 17.2 ± 2.4 ppm respectively. The concentrations of Th and U in LC and WLP samples determined by ?- spectrometry were 1156 ppm (4728 ± 22 Bq/kg) and 18.8 ppm and 1763.2 ppm (7211.4 Bq/kg) and 29.97 ppm respectively. This study showed that thorium concentrations were higher in WLP compare to LC. This study also indicate that WLP residue has high radioactivity of {sup 232}Th compared to Malaysian soil natural background (63 - 110 Bq/kg) and come under preview of Act 304 and regulations. In LC, the Ce and Nd concentrations determined by INAA were 13.2 ± 0.6% and 4.7 ± 0.1% respectively whereas the concentrations of La, Ce, Nd and Sm in WLP were 0.36 ± 0.04%, 1.6%, 0.22% and 0.06% respectively. This result showed that some amount of rare earth had not been extracted and remained in the WLP and may be considered to be reextracted.

  2. Application ApplicAtion

    E-Print Network [OSTI]

    Papautsky, Ian

    in the CCM Bulletin which can be downloaded from http://ccm.uc.edu/ admissions/application.html. You will automatically be considered for a talent-based scholarship when you audition/ interview for entrance into CCM is made. We would also like to invite you to tour CCM's excellent facilities and observe some classes

  3. Recovery of radioisotopes from nuclear waste for radio-scintillator-luminescence energy applications

    E-Print Network [OSTI]

    Alfred Bennun

    2012-08-16T23:59:59.000Z

    Extraction of the light weight radioisotopes (LWR) 89Sr/90Sr, from the expended nuclear bars in the Fukushima reactor, should have decreased the extent of contamination during the course of the accident. 89Sr applications could pay for the extraction of 89Sr/90Sr from nuclear residues. Added value could be obtained by using 89Sr for cancer treatments. Known technologies could be used to relate into innovative ways LWR, to obtain nuclear energy at battery scale. LWR interact by contact with scintillators converting \\beta-radiation into light-energy. This would lead to manufacturing scintillator lamps which operate independently of other source of energy. These lamps could be used to generate photoelectric energy. Engineering of radioisotopes scintillator photovoltaic cells, would lead to devices without moving parts.

  4. Recovery of radioisotopes from nuclear waste for radio-scintillator-luminescence energy applications

    E-Print Network [OSTI]

    Bennun, Alfred

    2012-01-01T23:59:59.000Z

    Extraction of the light weight radioisotopes (LWR) 89Sr/90Sr, from the expended nuclear bars in the Fukushima reactor, should have decreased the extent of contamination during the course of the accident. 89Sr applications could pay for the extraction of 89Sr/90Sr from nuclear residues. Added value could be obtained by using 89Sr for cancer treatments. Known technologies could be used to relate into innovative ways LWR, to obtain nuclear energy at battery scale. LWR interact by contact with scintillators converting \\beta-radiation into light-energy. This would lead to manufacturing scintillator lamps which operate independently of other source of energy. These lamps could be used to generate photoelectric energy. Engineering of radioisotopes scintillator photovoltaic cells, would lead to devices without moving parts.

  5. Visible Light Digital Camera --Up to 2.3MP resolution with LED lamps provides sharp images

    E-Print Network [OSTI]

    Short, Daniel

    electrical and industrial applications · Thumbnail Image Gallery -- Allows quick search of stored images Marker Function · Auto Hot/Cold spot marker function shows a spot within the area that automatically% of reading Image Storage (1GB micro SD card) 1000 Images 1000 Images 1000 Images Emissivity Table 0.1 to 1

  6. Bursty Impulse Noise Detection by Compressed University of British Columbia, Vancouver, BC, Canada, lampe@ece.ubc.ca

    E-Print Network [OSTI]

    Lampe, Lutz

    wires, no need to purchase spectrum), high penetration of the power distribution grid, and ease of use for data transmission over power lines. For power line communi- cations (PLC) systems with bandwidths application of CS for IN detection. Index Terms--Power line communications (PLC), impulse noise, compressed

  7. The Application of Ultraviolet Germicidal Technology in HVAC Systems

    E-Print Network [OSTI]

    Taylor, M. J.

    2000-01-01T23:59:59.000Z

    capability, which increases the operating costs of the equipment. Fortunately, IAQ degradation, foul odor, and increased expenses can be eliminated with the installation of the ultraviolet 'C' band (W-C) lamps. The ultraviolet germicidal lamps are designed...

  8. Demonstration Assessment of Light-Emitting Diode (LED) Retrofit Lamps at Intercontinental Hotel in San Francisco, CA

    SciTech Connect (OSTI)

    Miller, Naomi J.; Curry, Ku'Uipo J.

    2010-11-01T23:59:59.000Z

    This document is a report of observations and results obtained from a lighting demonstration project conducted under the U.S. Department of Energy (DOE) GATEWAY Demonstration Program. The program supports demonstrations of high-performance solid-state lighting (SSL) products in order to develop empirical data and experience with in-the-field applications of this advanced lighting technology. The DOE GATEWAY Demonstration Program focuses on providing a source of independent, third-party data for use in decision-making by lighting users and professionals; this data should be considered in combination with other information relevant to the particular site and application under examination. Each GATEWAY Demonstration compares SSL products against the incumbent technologies used in that location. Depending on available information and circumstances, the SSL product may also be compared to alternate lighting technologies. Though products demonstrated in the GATEWAY program have been prescreened and tested to verify their actual performance, DOE does not endorse any commercial product or in any way guarantee that users will achieve the same results through use of these products.

  9. Assessment of user satisfaction of restrooms with existing toilet fixtures and new low consumption fixtures

    E-Print Network [OSTI]

    Vankamamidi, Neelima Raman

    2004-11-15T23:59:59.000Z

    consumption automatic valves, such as, carrying capacities of reduced flows and about the overall cleanliness of the toilets (Reid, 1996). The low water quantities in the low consumption water closets may increase the ratio of solid waste in the drainpipe.... Surveys of complaints show that about 30-40% of the users were unhappy about cleanliness in restrooms (Thomas, 1998). 1.1 PROBLEM STATEMENT The purpose of the study is to analyze and compare the user satisfaction of the restrooms with existing toilet...

  10. COMPUTING APPLICATIONS APPLICATIONS

    E-Print Network [OSTI]

    Bader, David A.

    COMPUTING APPLICATIONS APPLICATIONS APPLICATIONS David A. Bader NEW MEXICO, USA Robert Pennington of the interconnect net- work and related software is shown by comparing the same application running on a large

  11. Plasma lighting, fiber optics, and daylight collectors: Toward the next revolution in high-efficiency illumination

    SciTech Connect (OSTI)

    Audin, L. [Columbia Univ., New York, NY (United States)

    1995-06-01T23:59:59.000Z

    Combining three recently marketed innovations may provide the next revolution in illumination, making many other recent advances eventually obsolete. The first is plasma lighting, pioneered by Fusion Lighting Inc. of Rockville, Maryland, and first commercially applied by Hutchins International Ltd. of Mississauga, Ontario. This microwave-generated light source yields very high-quality light with efficacies at or beyond high intensity discharge (HID) lamps. The source uses no mercury, thus eliminating lamp disposal problems, and has no cathode, thereby providing very long lamp life. Using no phosphors, it also has very short start and re-strike periods, and is dimmable. The second innovation is in the distribution of light. Commercial developments in fiber optics and light guides now provide products that transfer light from a remote point and distribute it like standard light fixtures. Advances in fiber optic communications and applications to decorative lighting have supplied relatively economical systems for mounting and directing light from both electric light sources and the sun. The third advance is a result of efforts to harness daylight. Unlike architectural daylighting that directs sunlight into perimeter areas through glazing, daylight collectors are roof-mounted devices that supply light to interior and underground spaces through hollow columns and open chases. Aided by improvements and cost reductions in sun-tracking (i.e., heliostatic) controls that capture and concentrate sunlight, such collectors offer a source of free light to locations that might otherwise never receive it. When combined together, these three options could offer a centralized building lighting system that pipes lumens to distribution devices replacing many existing lamps and fixtures.

  12. Materials Applications of Photoelectron Emission Microscopy....

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    a variety of photoexcitation sources including synchrotron emission, femtosecond laser pulses and conventional UV lamp emission. Each source has advantages, for example, fs...

  13. Health Implications of New Lamp Technology Progress with Lamp Safety

    E-Print Network [OSTI]

    California at Davis, University of

    (185pages) ­ "...no more dangerous than steam radiators" D Sliney 2006 #12;11/9/2013 3 F. H. Verhoeff--a Comprehensive Handbook, New York, Plenum, 1980, 500 pages 2006 UV and Blue-Light Hazards · UV and bl e light

  14. Lamps in the Leaping Over

    E-Print Network [OSTI]

    Scheidegger, Daniel

    2005-01-01T23:59:59.000Z

    on account of the formation of the physical body.This situation then is compared to the one of the bird called Khyung whichis capable of flying immediately after having left its egg, but whichpossesses this power only potentially as long it stays in its egg13... dbyings kyi sgron ma yi/ /rnal ‘byor nyams kyisa bon ‘debs/ /‘od snang zhing khams nyid du ‘char/ /sgron ma’i mtshan nyid mang bshad kyang//mngon sum mthong ba nyid yin no/ /snang ba yis ni ‘char byed lam/ /rkyen gyis ma bsgribs semscan mig /rgyal mo...

  15. Compact Fluorescent Plug-In Ballast-in-a-Socket

    SciTech Connect (OSTI)

    Rebecca Voelker

    2001-12-21T23:59:59.000Z

    The primary goal of this program was to develop a ballast system for plug-in CFLs (compact fluorescent lamps) that will directly replace standard metal shell, medium base incandescent lampholders (such as Levition No. 6098) for use with portable lamp fixtures, such as floor, table and desk lamps. A secondary goal was to identify a plug-in CFL that is optimized for use with this ballast. This Plug-in CFL Ballastin-a-Socket system will allow fixture manufacturers to easily manufacture CFL-based high-efficacy portable fixtures that provide residential and commercial consumers with attractive, cost-effective, and energy-efficient fixtures for use wherever portable incandescent fixtures are used today. The advantages of this proposed system over existing CFL solutions are that the fixtures can only be used with high-efficacy CFLs, and they will be more attractive and will have lower life-cycle costs than screw-in or adapter-based CFL retrofit solutions. These features should greatly increase the penetration of CFL's into the North American market. Our work has shown that using integrated circuits it is quite feasible to produce a lamp-fixture ballast of a size comparable to the current Edison-screw 3-way incandescent fixtures. As for price points for BIAS-based fixtures, end-users polled by the Lighting Research Institute at RPI indicated that they would pay as much as an additional $10 for a lamp containing such a ballast. The ballast has been optimized to run with a 26 W amalgam triple biax lamp in the base-down position, yet can accept non-amalgam versions of the lamp. With a few part alterations, the ballast can be produced to support 32 W lamps as well. The ballast uses GE's existing L-Comp[1] power topology in the circuit so that the integrated circuit design would be a design that could possibly be used by other CFL and EFL products with minor modifications. This gives added value by reducing cost and size of not only the BIAS, but also possibly other integral CFL and future dimmable integral and plug-in versions of the EFL products.

  16. High-Rise Residential Building Energy Analysis in Shanghai, China

    E-Print Network [OSTI]

    Zhou, Hongyun

    2014-07-30T23:59:59.000Z

    Weather for Energy Calculation 2.0 LBNL Lawrence Berkeley National Laboratory LED Light Emitting Diode MBE Mean Bias Error MVR model Multi-Variable Regression models NMBE Normalized Mean Bias Error PCM... heating. Therefore, lighting fixtures and domestic appliances used the most energy in this survey. For lighting fixtures, incandescent and fluorescent lamps are the most popular, only a small number of light-emitting diode (LED) lights were used (Chen...

  17. High-Rise Residential Building Energy Analysis in Shanghai, China 

    E-Print Network [OSTI]

    Zhou, Hongyun

    2014-07-30T23:59:59.000Z

    Weather for Energy Calculation 2.0 LBNL Lawrence Berkeley National Laboratory LED Light Emitting Diode MBE Mean Bias Error MVR model Multi-Variable Regression models NMBE Normalized Mean Bias Error PCM... heating. Therefore, lighting fixtures and domestic appliances used the most energy in this survey. For lighting fixtures, incandescent and fluorescent lamps are the most popular, only a small number of light-emitting diode (LED) lights were used (Chen...

  18. Blue-green phosphor for fluorescent lighting applications

    DOE Patents [OSTI]

    Srivastava, Alok; Comanzo, Holly; Manivannan, Venkatesan; Setlur, Anant Achyut

    2005-03-15T23:59:59.000Z

    A fluorescent lamp including a phosphor layer including Sr.sub.4 Al.sub.14 O.sub.25 :Eu.sup.2+ (SAE) and at least one of each of a red, green and blue emitting phosphor. The phosphor layer can optionally include an additional, deep red phosphor and a yellow emitting phosphor. The resulting lamp will exhibit a white light having a color rendering index of 90 or higher with a correlated color temperature of from 2500 to 10000 Kelvin. The use of SAE in phosphor blends of lamps results in high CRI light sources with increased stability and acceptable lumen maintenance over, the course of the lamp life.

  19. MICROCAVITYMICROCAVITY PLASMA SCIENCE AND RECENTPLASMA SCIENCE AND RECENT APPLICATIONS: BOUNDAPPLICATIONS: BOUND--FREE COUPLING, TRANSISTORFREE COUPLING, TRANSISTOR

    E-Print Network [OSTI]

    Shyy, Wei

    Electrode Glass6 mm 250 m LED Backlight Microcavity Lamp #12;OPERATION OF MICROCAVITY PLASMA DEVICES Plasma Surface Treatment High Intensity Plasma Arc Lamp Spark Gap Plasma Display (150 inch Panasonic ) Ozone generator Fluorescent Lamp Gas Laser #12;University of Illinois Laboratory for Optical Physics

  20. LEDs for Interior Office Applications Webcast

    Broader source: Energy.gov [DOE]

    In this March 18, 2010 webcast, Jason Tuenge and Michael Myer of Pacific Northwest National Laboratory described the performance and economic considerations of replacing either 4' T8 lamps or...

  1. Virtual Fixtures for Robotic Cardiac Surgery Shinsuk Park1

    E-Print Network [OSTI]

    ) harvest portion of robot-assisted coronary artery bypass graft proce- dures. A preoperative CT scan, motion constraints, and the need for cogni- tive spatio-motor remapping from the surgeon's hands a specified volume of tissue. 2 Methods This project focuses on robot-assisted minimally-invasive coronary

  2. Energy Star Lighting Fixtures: How Does THAT Work? | Department...

    Broader source: Energy.gov (indexed) [DOE]

    or include other special features, like motion sensors or automatic shut-off in daylight, to further help you reduce your lighting energy use. And the best part is that...

  3. Covered Product Category: Light Fixtures (Luminaires) | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: Theof"Wave theJuly 30, 2013DepartmentEnterprise ServersHot FoodofEnergy

  4. Cree LED Lighting Solutions Formerly LED Lighting Fixtures LLF | Open

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand JumpConceptual Model, clickInformationNew|CoreCp Holdings Llc JumpIowa:Crawfordsville, Iowa:Energy

  5. Implementation Applications

    E-Print Network [OSTI]

    Kazhdan, Michael

    ;Outline Theory Implementation Applications Background Intuition Definition Delaunay Triangulation Shape-Dimensional Shapes #12;Outline Theory Implementation Applications Background Intuition Definition Delaunay;Outline Theory Implementation Applications Background Intuition Definition Delaunay Triangulation Shape

  6. Lighting energy efficiency opportunities at Cheyenne Mountain Air Station

    SciTech Connect (OSTI)

    Molburg, J.C.; Rozo, A.J.; Sarles, J.K.; Haffenden, R.A.; Thimmapuram, P.R.; Cavallo, J.D.

    1996-06-01T23:59:59.000Z

    CMAS is an intensive user of electricity for lighting because of its size, lack of daylight, and 24-hour operating schedule. Argonne National Laboratory recently conducted a lighting energy conservation evaluation at CMAS. The evaluation included inspection and characterization of existing lighting systems, analysis of energy-efficient retrofit options, and investigation of the environmental effects that these lighting system retrofits could have when they are ready to be disposed of as waste. Argonne devised three retrofit options for the existing lighting systems at various buildings: (1) minimal retrofit--limited fixture replacement; (2) moderate retrofit--more extensive fixture replacement and limited application of motion detectors; and (3) advanced retrofit--fixture replacement, reduction in the number of lamps, expansion of task lighting, and more extensive application of motion detectors. Argonne used data on electricity consumption to analyze the economic and energy effects of these three retrofit options. It performed a cost analysis for each retrofit option in terms of payback. The analysis showed that lighting retrofits result in savings because they reduce electricity consumption, cooling load, and maintenance costs. The payback period for all retrofit options was found to be less than 2 years, with the payback period decreasing for more aggressive retrofits. These short payback periods derived largely from the intensive (24-hours-per-day) use of electric lighting at the facility. Maintenance savings accounted for more than half of the annual energy-related savings under the minimal and moderate retrofit options and slightly less than half of these savings under the advanced retrofit option. Even if maintenance savings were excluded, the payback periods would still be impressive: about 4.4 years for the minimal retrofit option and 2 years for the advanced option. The local and regional environmental impacts of the three retrofit options were minimal.

  7. Final Scientific/Technical Report "Arc Tube Coating System for Color Consistency"

    SciTech Connect (OSTI)

    Buelow, Roger; Jenson, Chris; Kazenski, Keith

    2013-03-21T23:59:59.000Z

    DOE has enabled the use of coating materials using low cost application methods on light sources to positively affect the output of those sources. The coatings and light source combinations have shown increased lumen output of LED fixtures (1.5%-2.0%), LED arrays (1.4%) and LED powered remote phosphor systems â?? Philips L-Prize lamp (0.9%). We have also demonstrated lifetime enhancements (3000 hrs vs 8000 hrs) and shifting to higher CRI (51 to 65) in metal halide high intensity discharge lamps with metal oxide coatings. The coatings on LEDs and LED products are significant as the market is moving increasingly more towards LED technology. Enhancements in LED performance are demonstrated in this work through the use of available materials and low cost application processes. EFOI used low refractive index fluoropolymers and low cost dipping processes for application of the material to surfaces related to light transmission of LEDs and LED products. Materials included Teflon AF, an amorphous fluorinated polymer and fluorinated acrylic monomers. The DOE SSL Roadmap sets goals for LED performance moving into the future. EFOIâ??s coating technology is a means to shift the performance curve for LEDs. This is not limited to one type of LED, but is relevant across LED technologies. The metal halide work included the use of sol-gel solutions resulting in silicon dioxide and titanium dioxide coatings on the quartz substrates of the metal halide arc tubes. The coatings were applied using low cost dipping processes.

  8. Analysis of federal policy options for improving US lighting energy efficiency: Commercial and residential buildings

    SciTech Connect (OSTI)

    Atkinson, B.A.; McMahon, J.E.; Mills, E.; Chan, P.; Chan, T.W.; Eto, J.H.; Jennings, J.D.; Koomey, J.G.; Lo, K.W.; Lecar, M.; Price, L.; Rubinstein, F.; Sezgen, O.; Wenzel, T.

    1992-12-01T23:59:59.000Z

    The US Department of Energy (DOE) has recognized the opportunity to achieve energy, economic, and environmental benefits by promoting energy-efficient lighting through federal policies, including lighting standards, financial incentives, and information programs. To assist in this process, the Office of Conservation and Renewable Energy`s Office of Codes and Standards invited Lawrence Berkeley Laboratory to assess prospective national impacts for a variety of policy options. Some progress has already been made in developing lighting policies at both the federal and state levels. The US DOE`s Office of Building Technologies has evaluated lighting efficiency incentives as part of its analysis for the National Energy Strategy. Fluorescent and incandescent lamp standards are included in the national Energy Policy Act of 1992 (P.L. 102-486, October 24, 1992). A few states have analyzed or implemented lamp and luminaire standards. Many policy-related issues merit further investigation. For example, there is considerable debate over issues such as mandatory or voluntary standards versus component labeling and other education-oriented strategies. Several different technologies are involved that interact with each other-lamps (incandescent, compact fluorescent, and HID), ballasts (for fluorescent and HID lamps), and fixtures with reflectors and lenses. Control systems and operation patterns must also be considered (timers, automated dimming, or occupancy sensors). Lighting applications are diverse, ranging from offices, restaurants, hallways, hospital operating rooms, to exterior lights. Lighting energy use influences heating and cooling requirements in buildings. Successful lighting system design must also address interactions between architectural design elements and daylighting availability. Proper system installation and ongoing operation and maintenance are crucial. The economic aspects of the preceding points must also be considered for policy making.

  9. Analysis of federal policy options for improving US lighting energy efficiency: Commercial and residential buildings

    SciTech Connect (OSTI)

    Atkinson, B.A.; McMahon, J.E.; Mills, E.; Chan, P.; Chan, T.W.; Eto, J.H.; Jennings, J.D.; Koomey, J.G.; Lo, K.W.; Lecar, M.; Price, L.; Rubinstein, F.; Sezgen, O.; Wenzel, T.

    1992-12-01T23:59:59.000Z

    The US Department of Energy (DOE) has recognized the opportunity to achieve energy, economic, and environmental benefits by promoting energy-efficient lighting through federal policies, including lighting standards, financial incentives, and information programs. To assist in this process, the Office of Conservation and Renewable Energy's Office of Codes and Standards invited Lawrence Berkeley Laboratory to assess prospective national impacts for a variety of policy options. Some progress has already been made in developing lighting policies at both the federal and state levels. The US DOE's Office of Building Technologies has evaluated lighting efficiency incentives as part of its analysis for the National Energy Strategy. Fluorescent and incandescent lamp standards are included in the national Energy Policy Act of 1992 (P.L. 102-486, October 24, 1992). A few states have analyzed or implemented lamp and luminaire standards. Many policy-related issues merit further investigation. For example, there is considerable debate over issues such as mandatory or voluntary standards versus component labeling and other education-oriented strategies. Several different technologies are involved that interact with each other-lamps (incandescent, compact fluorescent, and HID), ballasts (for fluorescent and HID lamps), and fixtures with reflectors and lenses. Control systems and operation patterns must also be considered (timers, automated dimming, or occupancy sensors). Lighting applications are diverse, ranging from offices, restaurants, hallways, hospital operating rooms, to exterior lights. Lighting energy use influences heating and cooling requirements in buildings. Successful lighting system design must also address interactions between architectural design elements and daylighting availability. Proper system installation and ongoing operation and maintenance are crucial. The economic aspects of the preceding points must also be considered for policy making.

  10. Pre-Retrofit Lighting Study at the University of Texas at Arlington

    E-Print Network [OSTI]

    Houcek, J. K.; Claridge, D. E.; Haberl, J. S.

    1994-01-01T23:59:59.000Z

    .T. Arlington campus and to determine whether lamp locations within the fixture would impact the amount of light output. This was followed by a series of lab tests conducted at the Energy Systems Lab, located on the Texas A&M University campus, to compare...

  11. ENERGY EFFICIENCY: A SMART INVESTMENTCritical deadline for incentives approaching

    E-Print Network [OSTI]

    California at Davis, University of

    % low 2-lamp T8 fluorescent, 20% low Adaptive LED, 20% low Title 24 2008 $4,709 $7,762 $9,923 Title 24 + occupancy sensors Ambient + occupancy sensors & daylighting LED ambient + occupancy sensors & daylighting,472 Energy savings beyond Title 24* -- 14% 78% LIGHTING AREA LIGHTS Per 100 pole fixtures 30% occupancy LED

  12. Power Planning Challenges in a Fast MarketChallenges in a Fast Market

    E-Print Network [OSTI]

    technology innovation Estimating old system turnover rates in face of new technologygy Take these issues up at ConservationTake these issues up at Conservation Resource Advisory Committee (CRAC) #12;OverviewOverview 4 #12 Stock T n O e Rates Stock Turn-Over Rates ­ Lamp burnout, fixture replacements & system remodels

  13. Apartment Hunting Checklist FURNITURE AND APPLIANCES

    E-Print Network [OSTI]

    Kravets, Robin

    ), close and lock? Hallway & outdoor lighting sufficient? STATE OF REPAIR Doors & windows fit securely light fixture covers broken or missing? Covers on light switches & electrical outlets? Electrical to be replaced? Cleaned? Enough light in each room? Need lamps? DON'T FORGET TO CHECK Enough electrical outlets

  14. Climate ActionPlan2010 nau.edu/green

    E-Print Network [OSTI]

    and Research · Section 2 Energy and Climate Change · Section 3 Operations · Section 4 Procurement · Section 5 Recycling and Waste Minimization · Section 6 Transportation · Section 7 Water · Appendix 1 Table of Contents. All light fixtures have been converted to electronic ballasts and T-8 lamps. The university has made

  15. HTS applications

    E-Print Network [OSTI]

    Noe, M; Fietz, W H; Goldacker, W; Schneider, Th

    2009-01-01T23:59:59.000Z

    Superconductivity has found many attractive applications in medicine, science, power systems, engineering, transport and electronics. One of the most prominent applications of superconductivity are superconducting magnets e.g. MRI magnets, NMR magnets, accelerator magnets, and magnets for fusion; most applications still use low temperature superconductors. Since the discovery of high temperature superconductivity (HTS) in 1986 there has been a tremendous progress in R&D of HTS material, wires and applications. Especially for power system applications, HTS offers considerable economic benefits. Many HTS demonstrator or prototype applications have been built and successfully tested, and some HTS applications like cables and superconducting fault current limiters seem very close to commercialisation. This paper gives an overview about the present and future HTS applications in power applications, high field magnets and current leads. In addition results of the Forschungszentrum Karlsruhe program to develop H...

  16. adjusting exterior magnetic: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Xavier - Institut de Mathmatiques ?lie Cartan, Universit Henri Poincar 123 Fixture Design and Installation Criteria for Interior and Exterior Lighting Applications...

  17. act rcra contingency: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    An empirical example is elaborated. Leydesdorff, Loet 2010-01-01 185 Emitting Diode (LED) Fixture Design and Installation Criteria for Exterior Lighting Applications in Contingency...

  18. Characterization and development of a new ceramic electrolyte for fuel cell applications

    SciTech Connect (OSTI)

    Not Available

    1991-06-01T23:59:59.000Z

    This work consisted of research directed toward characterization and development of new solid electrolyte materials that are potentially superior to other solid electrolyte materials currently under development (such as yttria-stabilized zirconia). The solid electrolyte technology described herein is based on new ceramic materials generally described as Bismuth Oxide doped with Niobium or Yyyrium oxides that were exclusively licensed to Solid-State Fuel Cells, Inc. by CeramPhysics, Inc. The technology is also based on further material, cell and stack technology concepts and manufacturing methods that were earlier reduced to practice by Solid- State Fuel Cells, Inc., and which are therefore proprietary to the Company. In this report a presentation of the overall program background is provided in Section 2.0. This includes a technical discussion of the technology in the context of the current state of the art. The task work description for the applicable portion of Phase 1 is presented in Section 3.0. Specifically, Phase 1-A comprises the following elements: Electrolyte materials development; testing of electrolyte stability under a reducing environment; development of cell electrodes; test fixtures design and facility erection; and preliminary coupon cell tests. 24 figs., 6 tabs.

  19. Estimate of federal relighting potential and demand for efficient lighting products

    SciTech Connect (OSTI)

    Shankle, S.A.; Dirks, J.A.; Elliott, D.B.; Richman, E.E.; Grover, S.E.

    1993-11-01T23:59:59.000Z

    The increasing level of electric utility rebates for energy-efficient lighting retrofits has recently prompted concern over the adequacy of the market supply of energy-efficient lighting products (Energy User News 1991). In support of the U.S. Department of Energy`s Federal Energy Management Program, Pacific Northwest Laboratory (PNL) has developed an estimate of the total potential for energy-efficient lighting retrofits in federally owned buildings. This estimate can be used to address the issue of the impact of federal relighting projects on the supply of energy-efficient lighting products. The estimate was developed in 1992, using 1991 data. Any investments in energy-efficient lighting products that occurred in 1992 will reduce the potential estimated here. This analysis proceeds by estimating the existing stock of lighting fixtures in federally owned buildings. The lighting technology screening matrix is then used to determine the minimum life-cycle cost retrofit for each type of existing lighting fixture. Estimates of the existing stock are developed for (1) four types of fluorescent lighting fixtures (2-, 3-, and 4-lamp, F40 4-foot fixtures, and 2-lamp, F96 8-foot fixtures, all with standard magnetic ballasts); (2) one type of incandescent fixture (a 75-watt single bulb fixture); and (3) one type of exit sign (containing two 20-watt incandescent bulbs). Estimates of the existing stock of lighting fixtures in federally owned buildings, estimates of the total potential demand for energy-efficient lighting products if all cost-effective retrofits were undertaken immediately, and total potential annual energy savings (in MWh and dollars), the total investment required to obtain the energy savings and the present value of the efficiency investment, are presented.

  20. Renewal Application

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Renewal Individual Permit Renewal Application The Permit expires March 31, 2014 and existing permit conditions will be in effect until a new permit is issued. The Permittees...

  1. Energy Saving and Good Quality Lighting for Indoor Applications

    E-Print Network [OSTI]

    Lange, H.

    2008-01-01T23:59:59.000Z

    with extremely high lamp efficacies, silver-coated aluminum lamellae optics for high luminares efficiency, as well as highly efficient electronic gear take care that the energy consumption is decreasing up to 40%, while the light quality is improving. Latest...

  2. High frequency inductive lamp and power oscillator

    DOE Patents [OSTI]

    Kirkpatrick, Douglas A.; Gitsevich, Aleksandr

    2005-09-27T23:59:59.000Z

    An oscillator includes an amplifier having an input and an output, a feedback network connected between the input of the amplifier and the output of the amplifier, the feedback network being configured to provide suitable positive feedback from the output of the amplifier to the input of the amplifier to initiate and sustain an oscillating condition, and a tuning circuit connected to the input of the amplifier, wherein the tuning circuit is continuously variable and consists of solid state electrical components with no mechanically adjustable devices including a pair of diodes connected to each other at their respective cathodes with a control voltage connected at the junction of the diodes. Another oscillator includes an amplifier having an input and an output, a feedback network connected between the input of the amplifier and the output of the amplifier, the feedback network being configured to provide suitable positive feedback from the output of the amplifier to the input of the amplifier to initiate and sustain an oscillating condition, and transmission lines connected to the input of the amplifier with an input pad and a perpendicular transmission line extending from the input pad and forming a leg of a resonant "T", and wherein the feedback network is coupled to the leg of the resonant "T".

  3. Das Prfzentrum Carsten Lampe, Daniel Eggert,

    E-Print Network [OSTI]

    Kalibrierlaboratorien" · Qualitätswesen analog den Anforderungen der ISO 9001 z.B. Sensorkalibriersystem / Dokumentation Prüfinstitut (durch DGWK, heute DIN CERTCO) · Seit 2003 ISO/IEC 17025 akkreditiert · Seit 2003 Prüfungen und;4 Was verlangt die Akkreditierung? ISO IEC 17025 ,,Allgemeine Anforderungen an die Kompetenz von Prüf- und

  4. General Service LED Lamps | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't YourTransport inEnergy0.pdfTechnologiesNATIONAL003Not Measurement SensitiveGeneralGeneral

  5. Fluorescent Lamp Ballasts | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO2: FinalOffers3.pdf0-45.pdf Flash2010-45.pdfFlash2011-43and Statement ofStrikeFluorescent

  6. Retail Replacement Lamps | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn'tOrigin ofEnergy at Waste-to-Energy usingof EnhancedRestructuring ourU.S.CALiPER Testing »

  7. DEFINING THE EFFECTIVENESS OF UV LAMPS

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville Power Administration wouldDECOMPOSITION OF CALCIUM SULFATE: A REVIEW OF THE LITERATURE W.

  8. Minerals Use in Safety Applications in the Workplace Many of the applications described below are found in and around the U.S. Geological Survey

    E-Print Network [OSTI]

    Torgersen, Christian

    communications equipment, including computers and cell phones, as well as in gallium-based solar cells that power that provide power to emergency lighting fixtures and backup power to medical equipment. #12;2 Cement. Copper--Copper wiring provides power for emergency lighting systems and power and signal transmission

  9. Retail Lamps Study 3.2: Lumen and Chromaticity Maintenance of LED A Lamps

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOn April 23, 2014, anEnergy nepdg_5251_5500.pdf Briefing forprovides LBNL-1470EOperated

  10. Demonstration Assessment of Light Emitting Diode (LED) Residential Downlights and Undercabinet Lights in the Lane County Tour of Homes, Eugene, Oregon

    SciTech Connect (OSTI)

    Ton, My K.; Richman, Eric E.; Gilbride, Theresa L.

    2008-11-10T23:59:59.000Z

    In August 2008 the Pacific Northwest National Laboratory (PNNL) conducted a light emitting diode (LED) residential lighting demonstration project for the U.S. Department of Energy (DOE), Office of Building Technologies, as part of DOE’s Solid State Lighting (SSL) Technology Demonstration Gateway Program. Two lighting technologies, an LED replacement for downlight lamps (bulbs) and an LED undercabinet lighting fixture, were tested in the demonstration which was conducted in two homes built for the 2008 Tour of Homes in Eugene, Oregon. The homes were built by the Lane County Home Builders Association (HBA), and Future B Homes. The Energy Trust of Oregon (ETO) also participated in the demonstration project. The LED downlight product, the LR6, made by Cree LED Lighting Solutions acts as a screw-in replacement for incandescent and halogen bulbs in recessed can downlights. The second product tested is Phillips/Color Kinetics’ eW® Profile Powercore undercabinet fixture designed to mount under kitchen cabinets to illuminate the countertop and backsplash surfaces. Quantitative and qualitative measurements of light performance and electrical power usage were taken at each site before and after initially installed halogen and incandescent lamps were replaced with the LED products. Energy savings and simple paybacks were also calculated and builders who toured the homes were surveyed for their responses to the LED products. The LED downlight product drew 12 Watts of power, cutting energy use by 82% compared to the 65W incandescent lamp and by 84% compared to the 75W halogen lamp. The LED undercabinet fixture drew 10 watts, cutting energy use by 83% to 90% compared to the halogen product, which was tested at two power settings: a low power 60W setting and a high power 105W setting. The LED downlight consistently provided more light than the halogen and incandescent lamps in horizontal measurements at counter height and floor level. It also outperformed in vertical illuminance measurements taken on the walls, indicating better lateral dispersion of the light. The undercabinet fixture’s light output was midway between the low and high power halogen undercabinet fixture light outputs (35.8 foot candle versus 13.4 fc and 53.4 fc) but it produced a more uniform light (max/min ratio of 7.0 versus 10.8). The color correlated temperature (CCT, the blue or yellowness) of the LED light correlated well with the halogen and incandescent lights (2675 K vs 2700 K). The color rendering of the LED downlight also correlated well at 92 CRI compared to 100 CRI for the halogen and incandescent lamps. The LED undercabinet fixture had measures of 2880 K CCT and 71 CRI compared to the 2700 K and 100 CRI scores for the halogen undercabinet fixture. Builders who toured the homes were surveyed; they gave the LED downlight high marks for brightness, said the undercabinet improved shadows and glare and said both products improved overall visibility, home appearance, and home value. Paybacks on the LED downlight ranged from 7.6 years (assuming electricity cost of 11 c/kWh) to 13.5 years (at 5C/kWh). Paybacks on the LED undercabinet fixture in a new home ranged from 4.4 years (11c/kWh electricity) to 7.6 years (5c/kWh) based on product costs of $95 per LED downlight and $140 per LED undercabinet fixture at 3 hrs per day of usage for the downlight and 2 hrs per day for the undercabinet lighting.

  11. INTEGRATED APPLICATION Page 1 ----------------------------SIGNATURE APPLICANT & DATE

    E-Print Network [OSTI]

    de Villiers, Marienne

    -Scientific / Veterinarian Sell / Trade / Buy / Receive / Donate Research #12;INTEGRATED APPLICATION Page 2 WEAPON (vii) HUNTING METHOD I. SIGNATURE OF APPLICANT / PROPERTY / LAND OWNER: Signature Date #12;

  12. Applicant Information

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office511041cloth DocumentationProductsAlternative FuelsSanta3Appliance and Equipment StandardsApplicant

  13. Energy Evaluation and Management in the Industrial Setting

    E-Print Network [OSTI]

    Morketter, R. C.

    1981-01-01T23:59:59.000Z

    yourself in some scenarios I'm going to present. But then I'm going to make you feel good again, because I'm going to outl ine an approach that is guaranteed to transform you and your energy management program into a bird of quite a different Michigan... management following Betty's easy-to-use recipes: check all steam traps, remove two lamps from every four-lamp fixture, repair leaky faucets, add insulation over the ceiling, turn thermostats down in winter, up in summer. Betty Crocker is really just a...

  14. Efficient Light Sources Today

    E-Print Network [OSTI]

    Hart, A. L.

    1982-01-01T23:59:59.000Z

    This paper reviews new lamp and lighting technology in terms of application and economic impact. Included are the latest advances in High Intensity Discharge systems, energy saving fluorescent lamps and ballasts, and the new state of the art high...

  15. Solid Oxide Fuel Cell Technology Stationary Power Application Project

    SciTech Connect (OSTI)

    Joseph Pierre

    2009-03-05T23:59:59.000Z

    The objectives of this program were to: (1) Develop a reliable, cost-effective, and production-friendly technique to apply the power-enhancing layer at the interface of the air electrode and electrolyte of the Siemens SOFC; (2) Design, build, install, and operate in the field two 5 kWe SOFC systems fabricated with the state-of-the-art cylindrical, tubular cell and bundle technology and incorporating advanced module design features. Siemens successfully demonstrated, first in a number of single cell tests and subsequently in a 48-cell bundle test, a significant power enhancement by employing a power-enhancing composite interlayer at the interface between the air electrode and electrolyte. While successful from a cell power enhancement perspective, the interlayer application process was not suitable for mass manufacturing. The application process was of inconsistent quality, labor intensive, and did not have an acceptable yield. This program evaluated the technical feasibility of four interlayer application techniques. The candidate techniques were selected based on their potential to achieve the technical requirements of the interlayer, to minimize costs (both labor and material), and suitably for large-scale manufacturing. Preliminary screening, utilizing lessons learned in manufacturing tubular cells, narrowed the candidate processes to two, ink-roller coating (IRC) and dip coating (DC). Prototype fixtures were successfully built and utilized to further evaluate the two candidate processes for applying the interlayer to the high power density Delta8 cell geometry. The electrical performance of interlayer cells manufactured via the candidate processes was validated. Dip coating was eventually selected as the application technique of choice for applying the interlayer to the high power Delta8 cell. The technical readiness of the DC process and product quality was successfully and repeatedly demonstrated, and its throughput and cost are amenable to large scale manufacturing. Two 5 kWe-class SOFC power systems were built and installed for the purpose of testing and evaluating state-of-the-art tubular cell and bundle technologies, advanced generator and module design features, balance-of-plant components, and cost reduction measures. Installed at the Phipps Conservatory and Botanical Gardens, a system operated for more than 17,500 hrs, delivering electrical power to the on-site grid and thermal energy in form of hot water for onsite utilization. Operation was typically autonomous, requiring minimal operator intervention, and achieved an overall availability of greater than 85%. Outages were primarily due to an unstable local grid, two weather related outages were experienced, and very few reliability issues were encountered despite harsh operating conditions. No repairs to the stack, module, or balance-of-plant were required. A second system was designed, built, delivered, and installed at a Siemens facility in Charlotte, North Carolina. Operational issues associated with the balance-of-plant were encountered during startup and prevented the system from operating.

  16. Research, Development and Demonstration of Micro-CHP System for Residential Applications

    SciTech Connect (OSTI)

    Karl Mayer

    2010-03-31T23:59:59.000Z

    ECR International and its joint venture company, Climate Energy, are at the forefront of the effort to deliver residential-scale combined heat and power (Micro-CHP) products to the USA market. Part of this substantial program is focused on the development of a new class of steam expanders that offers the potential for significantly lower costs for small-scale power generation technology. The heart of this technology is the scroll expander, a machine that has revolutionized the HVAC refrigerant compressor industry in the last 15 years. The liquid injected cogeneration (LIC) technology is at the core of the efforts described in this report, and remains an excellent option for low cost Micro-CHP systems. ECR has demonstrated in several prototype appliances that the concept for LIC can be made into a practical product. The continuing challenge is to identify economical scroll machine designs that will meet the performance and endurance requirements needed for a long life appliance application. This report describes the numerous advances made in this endeavor by ECR International. Several important advances are described in this report. Section 4 describes a marketing and economics study that integrates the technical performance of the LIC system with real-world climatic data and economic analysis to assess the practical impact that different factors have on the economic application of Micro-CHP in residential applications. Advances in the development of a working scroll steam expander are discussed in Section 5. A rigorous analytical assessment of the performance of scroll expanders, including the difficult to characterize impact of pocket to pocket flank leakage, is presented in Section 5.1. This is followed with an FEA study of the thermal and pressure induced deflections that would result from the normal operation of an advanced scroll expander. Section 6 describes the different scroll expanders and test fixtures developed during this effort. Another key technical challenge to the development of a long life LIC system is the development of a reliable and efficient steam generator. The steam generator and support equipment development is described in Section 7. Just one year ago, ECR International announced through its joint venture company, Climate Energy, that it was introducing to the USA market a new class of Micro-CHP product using the state-of-the-art Honda MCHP gas fired internal combustion (IC) engine platform. We now have installed Climate Energy Micro-CHP systems in 20 pilot demonstration sites for the 2005/2006 heating season. This breakthrough success with IC engine based systems paves the way for future advanced steam cycle Micro-CHP systems to be introduced.

  17. Performance of Personal Workspace Controls Final Report

    SciTech Connect (OSTI)

    Rubinstein, Francis; Kiliccote, Sila; Loffeld, John; Pettler,Pete; Snook, Joel

    2004-12-01T23:59:59.000Z

    One of the key deliverables for the DOE-funded controls research at LBNL for FY04 was the development of a prototype Personal Workspace Control system. The successful development of this system is a critical milestone for the LBNL Lighting Controls Research effort because this system demonstrates how IBECS can add value to today's Task Ambient lighting systems. LBNL has argued that by providing both the occupant and the facilities manager with the ability to precisely control the operation of overhead lighting and all task lighting in a coordinated manner, that task ambient lighting can optimize energy performance and occupant comfort simultaneously [Reference Task Ambient Foundation Document]. The Personal Workspace Control system is the application of IBECS to this important lighting problem. This report discusses the development of the Personal Workspace Control to date including descriptions of the different fixture types that have been converted to IBECS operation and a detailed description of the operation of PWC Scene Controller, which provides the end user with precise control of his task ambient lighting system. The objective, from the Annual Plan, is to demonstrate improvements in efficiency, lighting quality and occupant comfort realized using Personal Workspace Controls (PWC) designed to optimize the delivery of lighting to the individual's workstation regardless of which task-ambient lighting solution is chosen. The PWC will be capable of controlling floor-mounted, desk lamps, furniture-mounted and overhead lighting fixtures from a personal computer and handheld remote. The PWC will use an environmental sensor to automatically monitor illuminance, temperature and occupancy and to appropriately modulate ambient lighting according to daylight availability and to switch off task lighting according to local occupancy. [Adding occupancy control to the system would blunt the historical criticism of occupant-controlled lighting - the tendency of the occupant to leave lights on]. The PWC will be an entirely open networking system in which all manufacturers of task lights, furniture-mounted lighting and ballast manufacturers can participate and have a business position.

  18. Biological applications of an LCoS-BASED PROGRAMMABLE ARRAY MICROSCOPE (PAM)

    E-Print Network [OSTI]

    Rieger, Bernd

    -position high-intensity LED illuminator, modulated laser and lamp light sources, and an Andor iXon em of conventional CLSM systems. The combined use of a blue laser and parallel LED or visible laser sources permits

  19. Qualification and Demonstration Program for SSCL Lighting Systems In Park and Highway Applications

    SciTech Connect (OSTI)

    Don Osborne

    2005-06-30T23:59:59.000Z

    Meadow River Enterprises, Inc. (MRE) received a DOE cooperative agreement award in March of 2002 to develop Qualification and Demonstration Program for SSCL Lighting Systems in Parks and Highway Applications. (The SSCL lighting technology is the same technology that was developed under a DOE cooperative agreement DE-FC26-99FT40631.) This project spanned a period of 39 months and ended in June of 2005. Participates in the funding of this project included the US Department of Energy, Rahall Transportation Institute, West Virginia State Parks System, and Meadow River Enterprises, Inc. The total program costs totaled $850,000. The federal contribution to the program totaled $150,000 which represented 17.6% of the total costs. The SSCL is a rugged electroluminescent lamp and was designed for outdoor applications. However, since this is a new technology, there have never been any housing or solar packages assemble for its use in these outdoor applications. The purpose of this program was to develop several types of encasements and solar packages, then evaluate their performances over time. At the end of observations, a conclusion would be reached as to the methodology of encasement and solar package requirements. In addition this project was to evaluate the viability of this application for the SSCL product. In addition this project was to evaluate the feasibility of etching the top conductive layer of the SSCL panel to permit only the needed area to be illuminated; this would reduce the power requirements of a sign. All primary development objectives have been achieved.

  20. Postdoc Application Process

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Program Application Process Postdoc Application Process Point your career towards LANL: work with the best minds on the planet in an inclusive environment that is rich in...

  1. SAGE Application Process

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Application Process SAGE Application Process A National Science Foundation Research Experiences for Undergraduates program Contacts Institute Director Harald Dogliani-Los Alamos...

  2. Direct Methanol Fuel Cell Prototype Demonstration for Consumer Electronics Applications

    SciTech Connect (OSTI)

    Carlstrom, Charles, M., Jr.

    2009-07-07T23:59:59.000Z

    This report is the final technical report for DOE Program DE-FC36-04GO14301 titled “Direct Methanol Fuel Cell Prototype Demonstration for Consumer Electronics Applications”. Due to the public nature of this report some of the content reported in confidential reports and meetings to the DOE is not covered in detail in this report and some of the content has been normalized to not show actual values. There is a comparison of the projects accomplishments with the objectives, an overview of some of the key subsystem work, and a review of the three levels of prototypes demonstrated during the program. There is also a description of the eventual commercial product and market this work is leading towards. The work completed under this program has significantly increased the understanding of how Direct Methanol Fuel Cells (DMFC) can be deployed successfully to power consumer electronic devices. The prototype testing has demonstrated the benefits a direct methanol fuel cell system has over batteries typically used for powering consumer electronic devices. Three generations of prototypes have been developed and tested for performance, robustness and life. The technologies researched and utilized in the fuel cell stack and related subsystems for these prototypes are leveraged from advances in other industries such as the hydrogen fueled PEM fuel cell industry. The work under this program advanced the state of the art of direct methanol fuel cells. The system developed by MTI micro fuel cells aided by this program differs significantly from conventional DMFC designs and offers compelling advantages in the areas of performance, life, size, and simplicity. The program has progressed as planned resulting in the completion of the scope of work and available funding in December 2008. All 18 of the final P3 prototypes builds have been tested and the results showed significant improvements over P2 prototypes in build yield, initial performance, and durability. The systems have demonstrated robust operation when tested at various orientations, temperatures, and humidity levels. Durability testing has progressed significantly over the course of the program. MEA, engine, and system level steady state testing has demonstrated degradation rates acceptable for initial product introduction. Test duration of over 5000 hrs has been achieved at both the MEA and breadboard system level. P3 level prototype life testing on engines (stacks with reactant conditioning) showed degradation rates comparable to carefully constructed lab fixtures. This was a major improvement over the P2 and P1 engine designs, which exhibited substantial reductions in life and performance between the lab cell and the actual engine. Over the course of the work on the P3 technology set, a platform approach was taken to the system design. By working in this direction, a number of product iterations with substantial market potential were identified. Although the main effort has been the development of a prototype charger for consumer electronic devices, multiple other product concepts were developed during the program showing the wide variety of potential applications.

  3. Stirling engine application study

    SciTech Connect (OSTI)

    Teagan, W.P.; Cunningham, D.R.

    1983-03-01T23:59:59.000Z

    The potential for Stirling engine applications in the 0.5 to 5000 hp output range is assessed. The following are included: a market survey of potential engine applications, classification of applications, conventional engine markets and performance characteristics, status of Sterling engine systems, selection of application classes for Stirling engines, and the possible effects of technology, economic conditions, and regulatory changes. (MHR)

  4. Data:03576abd-1005-489d-b400-9a241524db7b | Open Energy Information

    Open Energy Info (EERE)

    - 2.00 Fiberglass Pole - 10.00fixture for 60 months Source or reference: ISU Documentation Source Parent: Comments Applicability Demand (kW) Minimum (kW): Maximum (kW):...

  5. Data:B36f31f9-5ba6-40a3-9fe4-ad6c4dc663a2 | Open Energy Information

    Open Energy Info (EERE)

    fixture Sector: Lighting Description: Source or reference: Rate Binder Ted 1 ISU Documentation Source Parent: Comments Applicability Demand (kW) Minimum (kW): Maximum (kW):...

  6. Data:09a4e5cb-5dfc-4fba-9e50-20703dd1644c | Open Energy Information

    Open Energy Info (EERE)

    - 2.00 Fiberglass Pole - 10.00fixture for 60 months Source or reference: ISU Documentation Source Parent: Comments Applicability Demand (kW) Minimum (kW): Maximum (kW):...

  7. Demonstration Assessment of Light Emitting Diode (LED) Commercial Garage Lights In the Providence Portland Medical Center, Portland, Oregon

    SciTech Connect (OSTI)

    Ton, My K.; Richman, Eric E.; Gilbride, Theresa L.

    2008-11-11T23:59:59.000Z

    This U.S. Department of Energy GATEWAY Demonstration project studied the applicability of light-emitting diode (LED) luminaires for commercial parking garage applications. High-pressure sodium (HPS) area luminaires were replaced with new LED area luminaires. The project was supported under the U.S. Department of Energy (DOE) Solid State Lighting Program. Other participants in the demonstration project included Providence Portland Medical Center in Portland, Oregon, the Energy Trust of Oregon, and Lighting Sciences Group (LSG) Inc. Pacific Northwest National Laboratory (PNNL) conducted the measurements and analysis of the results. PNNL manages GATEWAY demonstrations for DOE and represents their perspective in the conduct of the work. Quantitative and qualitative measurements of light and electrical power were taken at the site for both HPS and LED light sources. Economic costs were estimated and garage users’ responses to the new light sources were gauged with a survey. Six LED luminaires were installed in the below-ground parking level A, replacing six existing 150W HPS lamps spread out over two rows of parking spaces. Illuminance measurements were taken at floor level approximately every 4 ft on a 60-ft x 40-ft grid to measure light output of these LED luminaires which were termed the “Version 1” luminaires. PNNL conducted power measurements of the circuit in the garage to which the 6 luminaires were connected and determined that they drew an average of 82 W per lamp. An improved LED luminaire, Version 2, was installed in Level B of the parking garage. Illuminance measurements were not made of this second luminaire on site due to higher traffic conditions, but photometric measurements of this lamp and Version 1 were made in an independent testing laboratory and power usage for Version 2 was also measured. Version 1 was found to produce 3600 lumens and Version 2 was found to produce 4700 lumens of light and to consume 78 Watts. Maximum and minimum light levels were measured for the HPS and LED Version 1 luminaires and projected for the Version 2 luminaires. Maximum light levels were 23.51 foot candles, 20.54 fc, and 26.7 fc respectively and minimum light levels were 1.49 fc, 1.45 fc, and 1.88 fc. These results indicate very similar or even slightly higher light levels produced by the LED lamps, despite the higher lumen output of the HPS lamp. The LED lamps provide higher luminaire efficacy because all of the light is directed down and out. None of it is “lost” in the fixture. Also the HPS luminaire had poorly designed optics and a plastic covering that tended to get dirty and cracked, further decreasing the realized light output.[is this an accurate way to say this?] Consumer perceptions of the Version 2 LED were collected via a written survey form given to maintenance and security personnel. More than half felt the LED luminaires provided more light than the HPS lamps and a majority expressed a preference for the new lamps when viewing the relamped area through a security camera. Respondents commented that the LED luminaires were less glary, created less shadows, had a positive impact on visibility, and improved the overall appearance of the area. PNNL conducted an economic analysis and found that the Version 1 lamp produced annual energy savings of 955 kWh and energy cost savings of $76.39 per lamp at electricity rates of 6.5 cents per kWh and $105.03 at 11 cents per kWh. PNNL found that the Version 2 lamp produced annual energy savings of 991 kWh and energy cost savings of $79.26 per lamp at electricity rates of 6.5 cents per kWh and $108.98 at 11 cents per kWh. PNNL also calculated simple payback and found that Version 1 showed paybacks of 5.4 yrs at 6.5c/kWh and 4.1 yrs at 11c/kWh while Version 2 showed paybacks of 5.2 yrs at 6.5c/kWh and 3.9 yrs at 11c/kWh.

  8. Energy efficient alternatives to halogen torchieres

    SciTech Connect (OSTI)

    Siminovitch, M.; Marr, L.; Mitchell, J.; Page, E.

    1997-03-01T23:59:59.000Z

    A series of novel energy efficient torchiere systems have been developed using compact fluorescent lamps (CFLs). These systems were studied photometrically and compared with the performance of traditional commercially available tungsten halogen sources. Gonio-photometric data and power assessments indicate that significant lighting energy savings can be obtained by utilizing CFL sources instead of standard tungsten halogen sources. This energy savings is jointly due to the higher source efficacy of the CFLs and the surprisingly poor performance of the imported 300 Watt halogen lamps. Experimental data shows that a 50 to 60 Watt CFL will effectively lumen match a variety of 300 Watt tungsten halogen sources with 5 to 10 times the efficacy. CFL torchieres have additional benefits of higher power quality and cooler lamp operating temperature, making them safer fixtures.

  9. Residential Lighting End-Use Consumption Study: Estimation Framework and Initial Estimates

    SciTech Connect (OSTI)

    Gifford, Will R.; Goldberg, Miriam L.; Tanimoto, Paulo M.; Celnicker, Dane R.; Poplawski, Michael E.

    2012-12-01T23:59:59.000Z

    The U.S. DOE Residential Lighting End-Use Consumption Study is an initiative of the U.S. Department of Energy’s (DOE’s) Solid-State Lighting Program that aims to improve the understanding of lighting energy usage in residential dwellings. The study has developed a regional estimation framework within a national sample design that allows for the estimation of lamp usage and energy consumption 1) nationally and by region of the United States, 2) by certain household characteristics, 3) by location within the home, 4) by certain lamp characteristics, and 5) by certain categorical cross-classifications (e.g., by dwelling type AND lamp type or fixture type AND control type).

  10. Development of kinematic coupling preload guidelines through design and testing of an adjustable micromanufacturing fixture

    E-Print Network [OSTI]

    Evans, Brandon A. (Brandon Adam)

    2014-01-01T23:59:59.000Z

    In the growing field of non-lithographic micromanufacturing, the ability to properly align a workpiece to a machine limits the attainable tolerances in micro-electro-mechanical-systems (MEMS) prototyping. This limit has ...

  11. WhiteOptics' Low-Cost Reflector Composite Boosts LED Fixture Efficiency

    Broader source: Energy.gov [DOE]

    With the help of DOE funding, WhiteOptics has developed a composite coating that can be used to improve efficiency in backlit, indirect, and cavity-mixing LED luminaire designs by maximizing light reflection and output. The highly diffuse coating, which is based on a novel high-reflectance particle technology, allows for uniform distribution of light without exaggerating the point-source nature of the LEDs, and is intended to offer an overall system cost-improving solution for LED optics.

  12. The cost-effectiveness of retrofitting sanitary fixtures in restrooms of a university building

    E-Print Network [OSTI]

    Hwang, Byoung Hoon

    2004-09-30T23:59:59.000Z

    Architecture building A at Texas A&M University. The researcher directly measured the actual water-volume per flush of as-is, tune-up, low-consumption manual, and low-consumption automatic water closets and urinals. The data collected by these observations...

  13. Development of a reconfigurable fixture for the automated assembly and disassembly of high

    E-Print Network [OSTI]

    Boyer, Edmond

    . School of Mechanical, Materials and Manufacturing Engineering, The University of Nottingham; email data, are described. 1.Introduction The manufacturing of aero engines and its sub-modules is traditionally characterised by rigorous product quality requirements and tight tolerances. Additionally

  14. Development of VIRUS Alignment and Assembly Fixtures Amanda D. Collins1

    E-Print Network [OSTI]

    Energy Experiment (HETDEX). We plan to use a production line assembly process to construct the large Villanueva, Jr.1 1 Department of Physics and Astronomy, Texas A&M University, 4242 TAMU, College Station, TX, USA 77843-4242 2 McDonald Observatory, University of Texas at Austin, 1 University Station, C1402

  15. National Ignition Facility computational fluid dynamics modeling and light fixture case studies

    SciTech Connect (OSTI)

    Martin, R.; Bernardin, J.; Parietti, L.; Dennison, B.

    1998-02-01T23:59:59.000Z

    This report serves as a guide to the use of computational fluid dynamics (CFD) as a design tool for the National Ignition Facility (NIF) program Title I and Title II design phases at Lawrence Livermore National Laboratory. In particular, this report provides general guidelines on the technical approach to performing and interpreting any and all CFD calculations. In addition, a complete CFD analysis is presented to illustrate these guidelines on a NIF-related thermal problem.

  16. APPLICATION CONSTRUCTION LEADERSHIP COURSE

    E-Print Network [OSTI]

    Stephens, Graeme L.

    APPLICATION CONSTRUCTION LEADERSHIP COURSE RECOMMENDATION FORM CON464 Construction Leadership: __________________________ To be considered for the Construction Leadership course submit the following: Application with description in the construction industry 5) If your GPA

  17. Applications (Grid Tools)

    E-Print Network [OSTI]

    Buyya, Rajkumar

    Grid Fabric Software Grid Applications Core Grid Middleware User-Level Middleware (Grid Tools) !"# $ %& ' ( ) * #& + '& ' , - . / # ) ) 0 # * 1 PDB CDB Grid Fabric Hardware &+ '' + ) , '1 '1 ' % - * # ( Grid Fabric Software Grid Applications Core Grid Middleware User-Level Middleware (Grid Tools) !"# $ %& ' ( ) * #& + '& ' , - . / # ) ) 0

  18. Comments on ''Accuracy of Raman lidar water vapor calibration and its applicability to long-term measurements''

    SciTech Connect (OSTI)

    Whiteman, David N.; Venable, Demetrius; Landulfo, Eduardo

    2011-05-20T23:59:59.000Z

    In a recent publication, Leblanc and McDermid [Appl. Opt., 47, 5592 (2008)]APOPAI0003-693510.1364/AO.47.005592 proposed a hybrid calibration technique for Raman water vapor lidar involving a tungsten lamp and radiosondes. Measurements made with the lidar telescope viewing the calibration lamp were used to stabilize the lidar calibration determined by comparison with radiosonde. The technique provided a significantly more stable calibration constant than radiosondes used alone. The technique involves the use of a calibration lamp in a fixed position in front of the lidar receiver aperture. We examine this configuration and find that such a configuration likely does not properly sample the full lidar system optical efficiency. While the technique is a useful addition to the use of radiosondes alone for lidar calibration, it is important to understand the scenarios under which it will not provide an accurate quantification of system optical efficiency changes. We offer examples of these scenarios. Scanning of the full telescope aperture with the calibration lamp can circumvent most of these limitations. Based on the work done to date, it seems likely that the use of multiple calibration lamps in different fixed positions in front of the telescope may provide sufficient redundancy for long-term calibration needs. Further full-aperture scanning experiments, performed over an extended period of time, are needed to determine a ''best practice'' for the use of multiple calibration lamps in the hybrid technique.

  19. identity application sectionnine

    E-Print Network [OSTI]

    Derisi, Joseph

    , San Francisco | Public Affairs | Visual Identity Standards campaign material samples Graphic identity........................................................................................................81 fleet graphics...........................................................................................................82 fleet graphics application

  20. identity application sectionnine

    E-Print Network [OSTI]

    Derisi, Joseph

    ........................................................................................................81 fleet graphics...........................................................................................................82 fleet graphics application .........................................................................................................85 #12;University of California, San Francisco | Public Affairs | Visual Identity Standards

  1. Application Protocol Reference Architecture Application Protocol Reference Architecture

    E-Print Network [OSTI]

    van Sinderen, Marten

    Application Protocol Reference Architecture 165 Chapter 7 Application Protocol Reference Architecture This chapter proposes an alternative reference architecture for application protocols. The proposed reference architecture consists of the set of possible architectures for application protocols

  2. ERIP application instructions

    SciTech Connect (OSTI)

    Watt, D.M.

    1992-01-02T23:59:59.000Z

    This report provides background information and instructions to assist applicants in writing Energy-Related Inventions Program (ERIP) applications. Initial feedback fro usage for the new instructions shows that the best instructions would not be read and followed by all applicants. Applications from more than thirty applicants who have received the new instructions indicated that few had read the instructions. Based on this feedback, the instructions have been further revised to include a title page and table of contents. A warning was also added to advise applicants of the potential penalty of delayed review if these instructions are not followed. This revision was intended to address the possibility that some applicants did not see or bother to follow the instructions which followed the background information about ERIP. Included are two examples of ERIP applications which have been prepared for handout at workshops or mailing to applicants. Writing of example applications was time consuming and more difficult than expected for several reasons: (1) Full disclosures can be lengthy, very detailed, and technical. This contrasts with the desire to prepare examples which are comparatively short and easy for the non-technical person to read. (2) Disclosures contain confidential information which should not be published. (3) It is difficult to imagine that applicants will study examples when they do not bother to read the basic instructions.

  3. Technical applications of aerogels

    SciTech Connect (OSTI)

    Hrubesh, L.W.

    1997-08-18T23:59:59.000Z

    Aerogel materials posses such a wide variety of exceptional properties that a striking number of applications have developed for them. Many of the commercial applications of aerogels such as catalysts, thermal insulation, windows, and particle detectors are still under development and new application as have been publicized since the ISA4 Conference in 1994: e.g.; supercapacitors, insulation for heat storage in automobiles, electrodes for capacitive deionization, etc. More applications are evolving as the scientific and engineering community becomes familiar with the unusual and exceptional physical properties of aerogels, there are also scientific and technical application, as well. This paper discusses a variety of applications under development at Lawrence Livermore National Laboratory for which several types of aerogels are formed in custom sizes and shapes. Particular discussions will focus on the uses of aerogels for physics experiments which rely on the exceptional, sometimes unique, properties of aerogels.

  4. LANL application communication patterns

    SciTech Connect (OSTI)

    Pakiin, Scott [Los Alamos National Laboratory

    2011-01-10T23:59:59.000Z

    This brief presentation describes the communication patterns used by a set of unclassified applications developed at Los Alamos National Laboratory: XNobel/XRAGE/RAGE/SAGE, Krak, Sweep3D, and Partisn. It mentions which processes communicate with which other processes, whether the application is typically run in a strong-scaling mode or a weak-scaling mode, what message sizes are commonly used, and how the application's performance changes at scale.

  5. Computational Optimization and Applications

    E-Print Network [OSTI]

    15

    2015-04-02T23:59:59.000Z

    Pitman Advanced Publishing Program, Boston, 1984. [10] M. Hanke, Regularizing Levenberg-Marquardt scheme, with applications to inverse groundwater. 19. 1.

  6. Application Power Signature Analysis

    SciTech Connect (OSTI)

    Hsu, Chung-Hsing [ORNL] [ORNL; Combs, Jacob [Sonoma State University] [Sonoma State University; Nazor, Jolie [Sonoma State University] [Sonoma State University; Santiago, Fabian [Sonoma State University] [Sonoma State University; Thysell, Rachelle [Sonoma State University] [Sonoma State University; Rivoire, Suzanne [Sonoma State University] [Sonoma State University; Poole, Stephen W [ORNL] [ORNL

    2014-01-01T23:59:59.000Z

    The high-performance computing (HPC) community has been greatly concerned about energy efficiency. To address this concern, it is essential to understand and characterize the electrical loads of HPC applications. In this work, we study whether HPC applications can be distinguished by their power-consumption patterns using quantitative measures in an automatic manner. Using a collection of 88 power traces from 4 different systems, we find that basic statistical measures do a surprisingly good job of summarizing applications' distinctive power behavior. Moreover, this study opens up a new area of research in power-aware HPC that has a multitude of potential applications.

  7. High Efficancy Integrated Under-Cabinet Phosphorescent OLED

    SciTech Connect (OSTI)

    Michael Hack

    2001-10-31T23:59:59.000Z

    In this two year program Universal Display Corporation (UDC) together with the University of Michigan, Teknokon, developed and delivered an energy efficient phosphorescent OLED under cabinet illumination system. Specifically the UDC team goal was in 2011 to deliver five (5) Beta level OLED under cabinet lighting fixtures each consisting of five 6-inch x 6-inch OLED lighting panels, delivering over 420 lumens, at an overall system efficacy of >60 lm/W, a CRI of >85, and a projected lifetime to 70% of initial luminance to exceed 20,000 hours. During the course of this program, the Team pursued the commercialization of these OLED based under cabinet lighting fixtures, to enable the launch of commercial OLED lighting products. The UDC team was ideally suited to develop these novel and efficient solid state lighting fixtures, having both the technical experience and commercial distribution mechanisms to leverage work performed under this contract. UDC's business strategy is to non-exclusively license its PHOLED technology to lighting manufacturers, and also supply them with our proprietary PHOLED materials. UDC is currently working with several licensees who are manufacturing OLED lighting panels using our technology. During this 2 year program, we further developed our high efficiency white Phosphorescent OLEDs from the first milestone, achieving a 80 lm/W single pixel to the final milestone, achieving an under-cabinet PHOLED lighting system that operates at 56 lm/W at 420 lumens. Each luminaire was comprised of ten 15cm x 7.5cm lighting modules mounted in outcoupling enhancement lenses and a control module. The lamps modules are connected together using either plugs or wires with plugs on each end, allowing for unlimited configurations. The lamps are driven by an OLED driver mounted in an enclosure which includes the AC plug. As a result of advancements gained under this program, the path to move OLED lighting panels from development into manufacturing has been further realized. We have found that under-cabinet lighting is an ideal first entry product opportunity to launch OLED lighting for residential applications. From the studies that we have performed, our PHOLED under-cabinet lighting system performance is very similar to many of the current commercially available LED under-cabinet luminaires. We also found that the projected cost of PHOLED luminaire should be comparable to the LED luminaire by 2015. With the additional benefits of PHOLED lighting, no glare, better uniformity and low operating temperature, it can be easily seen how the PHOLED under-cabinet luminaire could be preferred over the LED competition. Although the metrics we set for this program were extremely aggressive, the performance we achieved and reported, represents a very significant advancement in the OLED lighting industry.

  8. Conservation Potential of Compact Fluorescent Lamps in India and Brazil

    E-Print Network [OSTI]

    Gadgil, A.J.

    2008-01-01T23:59:59.000Z

    cost of avoided peak installed capacity is 6 and 9.5 timesthe cost of new installed capacity for India and Brazil. Theappear to require an installed capacity of more than 100 GW

  9. Ancient Lamps, Earrings Yield Their Secrets Under Neutron Imaging...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    News Careers Work with ORNL About ORNL Visiting ORNL Events and Conferences Highlights Success Stories Contact Us Index Home | ORNL | Highlights SHARE Neutron imaging gives...

  10. New LED light sources and lamps for general illumination

    E-Print Network [OSTI]

    , Henrik Pedersen and Paul Michael Petersen Risø DTU, Optics and Plasma Research Department, DK-4000

  11. Zero energy-storage ballast for compact fluorescent lamps

    DOE Patents [OSTI]

    Schultz, W.N.; Thomas, R.J.

    1999-08-31T23:59:59.000Z

    A CFL ballast includes complementary-type switching devices connected in series with their gates connected together at a control node. The switching devices supply a resonant tank circuit which is tuned to a frequency near, but slightly lower than, the resonant frequency of a resonant control circuit. As a result, the tank circuit restarts oscillations immediately following each zero crossing of the bus voltage. Such rapid restarts avoid undesirable flickering while maintaining the operational advantages and high efficacy of the CFL ballast. 4 figs.

  12. Conservation Potential of Compact Fluorescent Lamps in India and Brazil

    E-Print Network [OSTI]

    Gadgil, A.J.

    2008-01-01T23:59:59.000Z

    utility managed program in an LDC).3r'e split the additionalseems obvious that almost no LDC domestic consumers will buy

  13. arc discharge lamp: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    TR, were determined. It was found that there is no local LTE in this arc discharge air plasma during its spacetime evolution, and effects of strong non-izothermality have a...

  14. Zero energy-storage ballast for compact fluorescent lamps

    DOE Patents [OSTI]

    Schultz, William Newell (Niskayuna, NY); Thomas, Robert James (Rexford, NY)

    1999-01-01T23:59:59.000Z

    A CFL ballast includes complementary-type switching devices connected in series with their gates connected together at a control node. The switching devices supply a resonant tank circuit which is tuned to a frequency near, but slightly lower than, the resonant frequency of a resonant control circuit. As a result, the tank circuit restarts oscillations immediately following each zero crossing of the bus voltage. Such rapid restarts avoid undesirable flickering while maintaining the operational advantages and high efficacy of the CFL ballast.

  15. Conservation Potential of Compact Fluorescent Lamps in India and Brazil

    E-Print Network [OSTI]

    Gadgil, A.J.

    2008-01-01T23:59:59.000Z

    1988. The private sector in Brazil owned (in 1986) 40% ofElectricity Conservation in Brazil: Potential and Pro-electricity consumption in Brazil's residential sector was

  16. Conservation Potential of Compact Fluorescent Lamps in India and Brazil

    E-Print Network [OSTI]

    Gadgil, A.J.

    2008-01-01T23:59:59.000Z

    energia: 0 Horario de Verao) Proceedings, I Congres- so Brasileiro de Planejamento Energetico (forthcoming), Universidade Es- tadual de Campinas, Sao Paulo, Brasil,

  17. Transport and equilibrium in molecular plasmas: the sulfur lamp

    E-Print Network [OSTI]

    Eindhoven, Technische Universiteit

    . . . . . . . . . . . . . . . . . . . . . . . . . . 23 2.5.3 Thermal conductivity module . . . . . . . . . . . . . . . . . . . . . 24 2.5.4 Electrical . . . . . . . . . . . . . . . . . . . . . . . . 18 2.4.4 Generation and transport of radiation . . . . . . . . . . . . . . . . . 19 2.4.5 Boundary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 2.6.3 Electric field strength . . . . . . . . . . . . . . . . . . . . . . . . . . 28 2.6.4 Spectra

  18. Phosphor blends for high-CRI fluorescent lamps

    DOE Patents [OSTI]

    Setlur, Anant Achyut (Niskayuna, NY); Srivastava, Alok Mani (Niskayuna, NY); Comanzo, Holly Ann (Niskayuna, NY); Manivannan, Venkatesan (Clifton Park, NY); Beers, William Winder (Chesterland, OH); Toth, Katalin (Pomaz, HU); Balazs, Laszlo D. (Budapest, HU)

    2008-06-24T23:59:59.000Z

    A phosphor blend comprises at least two phosphors each selected from one of the groups of phosphors that absorb UV electromagnetic radiation and emit in a region of visible light. The phosphor blend can be applied to a discharge gas radiation source to produce light sources having high color rendering index. A phosphor blend is advantageously includes the phosphor (Tb,Y,LuLa,Gd).sub.x(Al,Ga).sub.yO.sub.12:Ce.sup.3+, wherein x is in the range from about 2.8 to and including 3 and y is in the range from about 4 to and including 5.

  19. Conservation Potential of Compact Fluorescent Lamps in India and Brazil

    E-Print Network [OSTI]

    Gadgil, A.J.

    2008-01-01T23:59:59.000Z

    Residential Energy Demand in Brazil and Income Classes:in Brazil: Potential and Pro- gress", ENERGY, vol. 13, no.decreasing energy services in India and Brazil. The initial

  20. Apparatus to facilitate lengthening the life of incandescent lamps

    SciTech Connect (OSTI)

    Spissinger, F.H.

    1987-03-17T23:59:59.000Z

    An energizing circuit is described for an incandescent bulb comprising a transformer having a primary winding connectable to an AC mains source and first and second secondary windings for producing first and second voltages. The first secondary winding is connected to an input of a first full-wave rectifier means and the second secondary winding is connected to an input of a second full-wave rectifier means, the full-wave rectifier means having outputs connected in parallel across the bulb. The first voltage is sufficient to fully illuminate the bulb and the second voltage is sufficient to maintain the bulb warm but with little or no light output, a first switch being connected between the first secondary winding and the first rectifier means whereby, when the first switch is open, the bulb is energized solely by the second voltage.

  1. Energy Cost Calculator for Compact Fluorescent Lamps | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the YouTube|6721 Federal Register /of Energy 3 BTOWebinarSupplies;Ice Machines

  2. Conservation Potential of Compact Fluorescent Lamps in India and Brazil

    E-Print Network [OSTI]

    Gadgil, A.J.

    2008-01-01T23:59:59.000Z

    household income is a strong determinant of household electricity use, analysis for different prices

  3. Candelabra and Intermediate Base Lamps Enforcement Policy Statement |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the YouTube platformBuilding RemovalCSS Letter -SeptemberWorkshop |

  4. LED Performance Specification Series: T8 Replacement Lamps

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't YourTransport(FactDepartment ofLetter Report:40PM toLED Lighting Facts LED LightingOutdoor

  5. LED T8 Replacement Lamps | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't YourTransport(FactDepartment ofLetter Report:40PM toLED Lighting Facts LED LightingOutdoorLEDT8

  6. Covered Product Category: Compact Fluorescent Lamps | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the YouTube platformBuildingCoalComplex(GC-72)Columbia Government | Department ofProducts

  7. LED T8 Replacement Lamps | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreaking ofOil & Gas » MethaneJohnsonKristina Pflanz About UsT8 Replacement

  8. Medium Base Compact Fluorescent Lamps | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't YourTransport(FactDepartment3311, 3312), October 20122Technologies61-2008 JuneMedication List

  9. Candelabra and Intermediate Base Lamps Enforcement Policy Statement |

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 1112011AT&T, Inc.'sEnergy BushCalifornia Valley Solar RanchAwardFirst Report toDepartment

  10. Ancient Lamps, Earrings Yield Their Secrets Under Neutron Imaging |

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625govInstrumentstdmadapInactiveVisiting the TWP TWPAlumni Alumni PARC/I-CARESAnalysis &| Princeton Plasma

  11. WINTER BREAK HOUSING APPLICATION

    E-Print Network [OSTI]

    Hartman, Chris

    WINTER BREAK HOUSING APPLICATION RESIDENCE HALLS WILL BE CLOSED FROM 12:00PM (NOON), DECEMBER 19-6860 WWW.UAF.EDU/RESLIFE · EMAIL UAF-HOUSING@ALASKA.EDU TEL (907) 474-7247 · FAX (907) 474-6423 WINTER halls open need to complete the winter break housing application. Students that apply for housing before

  12. 2011 Clinic Application

    E-Print Network [OSTI]

    Aalberts, Daniel P.

    2011 Clinic Application These clinics are designed to be a two day event Application Due: June 1st as for us to get the best sense of you, it is important that you attend both days of the clinic for Dinner in the Dining Hall the night before the clinic. Dinner for participant and 2 other family members

  13. Wind energy applications guide

    SciTech Connect (OSTI)

    anon.

    2001-01-01T23:59:59.000Z

    The brochure is an introduction to various wind power applications for locations with underdeveloped transmission systems, from remote water pumping to village electrification. It includes an introductory section on wind energy, including wind power basics and system components and then provides examples of applications, including water pumping, stand-alone systems for home and business, systems for community centers, schools, and health clinics, and examples in the industrial area. There is also a page of contacts, plus two specific example applications for a wind-diesel system for a remote station in Antarctica and one on wind-diesel village electrification in Russia.

  14. Heat Pumps - Theory and Applications

    E-Print Network [OSTI]

    Altin, M.

    1982-01-01T23:59:59.000Z

    compressors (heat pumps) with actual applications in Monsanto. Guidelines for possible application areas are drawn from the analysis, and conclusions are drawn both about the usefulness of exergy analysis and about the heat pump application areas....

  15. web identity application sectioneleven

    E-Print Network [OSTI]

    Derisi, Joseph

    web identity application sectioneleven 99 contents elements of webpage design......................................................................... 100-101 web development and design considerations web banners is required for all official UCSF webpages. This banner includes a required link

  16. Neutron sources and applications

    SciTech Connect (OSTI)

    Price, D.L. [ed.] [Argonne National Lab., IL (United States); Rush, J.J. [ed.] [National Inst. of Standards and Technology, Gaithersburg, MD (United States)

    1994-01-01T23:59:59.000Z

    Review of Neutron Sources and Applications was held at Oak Brook, Illinois, during September 8--10, 1992. This review involved some 70 national and international experts in different areas of neutron research, sources, and applications. Separate working groups were asked to (1) review the current status of advanced research reactors and spallation sources; and (2) provide an update on scientific, technological, and medical applications, including neutron scattering research in a number of disciplines, isotope production, materials irradiation, and other important uses of neutron sources such as materials analysis and fundamental neutron physics. This report summarizes the findings and conclusions of the different working groups involved in the review, and contains some of the best current expertise on neutron sources and applications.

  17. Leadership Honors Application Materials

    E-Print Network [OSTI]

    Pantaleone, Jim

    1 Leadership Honors Application Materials Spring 2013 Purpose Leadership Honors are awarded to individuals upon graduation in order to recognize and honor their leadership contributions to the University of Alaska Anchorage while maintaining academic excellence. Leadership activities must enhance

  18. Leadership Honors Application Materials

    E-Print Network [OSTI]

    Pantaleone, Jim

    1 Leadership Honors Application Materials Fall 2009 Purpose Leadership Honors are awarded to individuals upon graduation in order to recognize and honor their leadership contributions to the University of Alaska Anchorage while maintaining academic excellence. Leadership activities must enhance

  19. Leadership Honors Application Materials

    E-Print Network [OSTI]

    Pantaleone, Jim

    1 Leadership Honors Application Materials Fall 2012 Purpose Leadership Honors are awarded to individuals upon graduation in order to recognize and honor their leadership contributions to the University of Alaska Anchorage while maintaining academic excellence. Leadership activities must enhance

  20. Leadership Honors Application Materials

    E-Print Network [OSTI]

    Pantaleone, Jim

    1 Leadership Honors Application Materials Spring 2012 Purpose Leadership Honors are awarded to individuals upon graduation in order to recognize and honor their leadership contributions to the University of Alaska Anchorage while maintaining academic excellence. Leadership activities must enhance

  1. Photovoltaic systems and applications

    SciTech Connect (OSTI)

    Not Available

    1982-01-01T23:59:59.000Z

    Abstracts are given of presentations given at a project review meeting held at Albuquerque, NM. The proceedings cover the past accomplishments and current activities of the Photovoltaic Systems Research, Balance-of-System Technology Development and System Application Experiments Projects at Sandia National Laboratories. The status of intermediate system application experiments and residential system analysis is emphasized. Some discussion of the future of the Photovoltaic Program in general, and the Sandia projects in particular is also presented.

  2. Applications of cavity optomechanics

    SciTech Connect (OSTI)

    Metcalfe, Michael [Booz Allen Hamilton, 3811 Fairfax Drive, Arlington, Virginia 22203 (United States)

    2014-09-15T23:59:59.000Z

    “Cavity-optomechanics” aims to study the quantum properties of mechanical systems. A common strategy implemented in order to achieve this goal couples a high finesse photonic cavity to a high quality factor mechanical resonator. Then, using feedback forces such as radiation pressure, one can cool the mechanical mode of interest into the quantum ground state and create non-classical states of mechanical motion. On the path towards achieving these goals, many near-term applications of this field have emerged. After briefly introducing optomechanical systems and describing the current state-of-the-art experimental results, this article summarizes some of the more exciting practical applications such as ultra-sensitive, high bandwidth accelerometers and force sensors, low phase noise x-band integrated microwave oscillators and optical signal processing such as optical delay-lines, wavelength converters, and tunable optical filters. In this rapidly evolving field, new applications are emerging at a fast pace, but this article concentrates on the aforementioned lab-based applications as these are the most promising avenues for near-term real-world applications. New basic science applications are also becoming apparent such as the generation of squeezed light, testing gravitational theories and for providing a link between disparate quantum systems.

  3. Active noise and vibration control for vehicular applications

    SciTech Connect (OSTI)

    Lewis, P.S.; Ellis, S.

    1998-12-31T23:59:59.000Z

    This is the final report of a one-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). This project investigated semi-active suspension systems based on real time nonlinear control of magneto-rheological (MR) shock absorbers. This effort was motivated by Laboratory interactions with the automobile industry and with the Defense Department. Background research and a literature search on semi-active suspensions was carried out. Numerical simulations of alternative nonlinear control algorithms were developed and adapted for use with an MR shock absorber. A benchtop demonstration system was designed, including control electronics and a mechanical demonstration fixture to hold the damper/spring assembly. A custom-made MR shock was specified and procured. Measurements were carried out at Los Alamos to characterize the performance of the device.

  4. Job Application Portal Manual for the Job Application Portal

    E-Print Network [OSTI]

    Johannesson, Henrik

    Job Application Portal Manual for the Job Application Portal in the University of Gothenburg e-recruitment system #12;The University of Gothenburg 2/10 Contents The University of Gothenburg's Job Application.............................................................................................................................................. 10 #12;The University of Gothenburg 3/10 The University of Gothenburg's Job Application Portal

  5. Controls for Solid-State Lighting

    SciTech Connect (OSTI)

    Rubinstein, Francis

    2007-06-22T23:59:59.000Z

    This study predicts new hybrid lighting applications for LEDs. In hybrid lighting, LEDs provide a low-energy 'standby' light level while another, more powerful, efficient light source provides light for occupied periods. Lighting controls will allow the two light sources to work together through an appropriate control strategy, typically motion-sensing. There are no technical barriers preventing the use of low through high CRI LEDs for standby lighting in many interior and exterior applications today. The total luminous efficacy of LED systems could be raised by increasing the electrical efficiency of LED drivers to the maximum practically achievable level (94%). This would increase system luminous efficacy by 20-25%. The expected market volumes for many types of LEDs should justify the evolution of new LED drivers that use highly efficient ICs and reduce parts count by means of ASICs. Reducing their electronics parts count by offloading discrete components onto integrated circuits (IC) will allow manufacturers to reduce the cost of LED driver electronics. LED luminaire manufacturers will increasingly integrate the LED driver and thermal management directly in the LED fixture. LED luminaires of the future will likely have no need for separable lamp and ballast because the equipment life of all the LED luminaire components will all be about the same (50,000 hours). The controls and communications techniques used for communicating with conventional light sources, such as dimmable fluorescent lighting, are appropriate for LED illumination for energy management purposes. DALI has been used to control LED systems in new applications and the emerging ZigBee protocol could be used for LEDs as well. Major lighting companies are already moving in this direction. The most significant finding is that there is a significant opportunity to use LEDs today for standby lighting purposes. Conventional lighting systems can be made more efficient still by using LEDs to provide a low-energy standby state when lower light levels are acceptable.

  6. Building Facebook Application using Python

    E-Print Network [OSTI]

    Wu, S. Felix

    Building Facebook Application using Python ECS-15, Fall 2010 Prantik Bhattacharyya #12;· Farmville ­ Game ­ 57.5m users ­ http://www.facebook.com/FarmVille · Causes ­ Issues/Movement ­ 26.4m users ­ http://www.facebook.com/causes Facebook Applications #12;Outline · Facebook Applications · Writing Applications · Development

  7. Optimization Online - Applications — Science and Engineering ...

    E-Print Network [OSTI]

    Applications — Science and Engineering Submissions - 2007. January 2007. Control Applications ... Processor Speed Control with Thermal Constraints

  8. Summary of UTMB O&M Project: Energy Conservation Potential in Five Buildings

    E-Print Network [OSTI]

    Liu, M.; Athar, A.; Reddy, T. A.; Claridge, D. E.; Haberl, J. S.

    1993-01-01T23:59:59.000Z

    by 88 Watts per fixture if two lamps and a ballast are disconnected. In addition, a formal program of turning-off lights in corridors and elevator lobbies after hours would contribute to less energy consumption. Texas State Energy Conservation Office...ESL-TR-93/10-03 LoanSTAR Monitoring and Analysis Program Summary of UTMB O&M Project: ENERGY CONSERVATION POTENTIAL IN FIVE BUILDINGS Submitted to the Texas State Energy Conservation Office By the Monitoring and Analysis Task E (O&M) Dr. Mingsheng...

  9. GUARANTEED HOUSING APPLICATION PROCESS

    E-Print Network [OSTI]

    Rose, Michael R.

    GUARANTEED HOUSING APPLICATION PROCESS 20152016 Housing Options 2014 Parents and Family Day Welcome! #12;Who is eligible for Guaranteed Housing? Freshmen that live on campus their entire first year for guaranteed housing can apply to the housing waitlist later in the school year. #12;What's the Guarantee

  10. Introducing Web Application Development

    E-Print Network [OSTI]

    Ding, Wei

    Introducing Web Application Development Instructor: Dr Wei Ding Development Instructor: Dr.Wei Ding Fall 2009 1CS 437/637 Database-BackedWeb Sites andWeb Services Introduction: Internet vs. World Wide Web Internet is an interconnected network of thousands ofInternet is an interconnected network

  11. APPLICATION PRESIDENTIAL INTERNSHIP

    E-Print Network [OSTI]

    Tipple, Brett

    APPLICATION PRESIDENTIAL INTERNSHIP IN HIGHER EDUCATION 2012-2013 The Presidential Internship perspective. The Presidential Internship in Higher Education program is looking for a small, diverse group and community leaders. To qualify for this internship, a student must: 1. Exhibit an interest in higher

  12. MAIN APPLICATIONS Spot welding

    E-Print Network [OSTI]

    De Luca, Alessandro

    IRB 6400 MAIN APPLICATIONS Spot welding Press tending Material handling Machine tending Palletizing N Poke welding All IRB 6400R-versions have Foundry Plus protection. For details, see under manipulator 6400PE 1600 kg Others 2060 - 2390 kg ENVIRONMENT Ambient temperature Manipulator 5 ­ 50°C Relative

  13. COMPUTER APPLICATIONS --FALL 2008 --

    E-Print Network [OSTI]

    Smith-Konter, Bridget

    and bathymetry data, display it in 3-D, overlay geologic data of interest, and create a flight path (animated movie) of a 3-D data set (a visualization) using the Fledermaus IVS software package. Fledermuas is a powerful, interactive 3-D data visualization system that is used for a variety of geoscience applications

  14. Content Provider Speeds Application

    E-Print Network [OSTI]

    Fisher, Kathleen

    protocols like SMPP for SMS and MM7 for MMS are industry standards, carriers typically layer their own APIs.0 standards," says Rose, "and we thought that would help speed development." The AT&T API Platform includesContent Provider Speeds Application Development AT&T API Platform cuts development time and costs

  15. Permit application modifications

    SciTech Connect (OSTI)

    NONE

    1995-11-01T23:59:59.000Z

    This document contains the Permit Application Modifications for the Y-12 Industrial Landfill V site on the Oak Ridge Reservation. These modifications include the assessment of stability of the proposed Landfill V under static and loading conditions. Analyses performed include the general slope stability, veneer stability of the bottom liner and cover system, and a liquefaction potential assessment of the foundation soils.

  16. Undergraduate Application and Scholarships

    E-Print Network [OSTI]

    Sherrill, David

    with Professor Nils Kroger, studying new materials made by microalgae for use in nano- technological applications such as biotechnology, renewable energy, nanotechnology, modern pharmaceuticals, environmental concerns, and forensics, which play central roles in the nation's health, nutrition, security, energy generation, and economy

  17. Solid-State Lighting with High Brightness, High Efficiency, and Low Cost

    E-Print Network [OSTI]

    Gilchrist, James F.

    -based lamp for lighthouse application were discussed at the system level ("Implementation and test of a LED- based lamp for a lighthouse" by L. Mercatelli et al.). Such applications of LED in lighthouse have-emitting diode (LED) is the most popular technique due to its advantages of small volume, long lifetime, high

  18. Textbook Adoption Application Guide Entering the Application ..................................................................................... 2

    E-Print Network [OSTI]

    Sura, Philip

    allows you to search for your assigned course(s) by: Term, Location, Academic Department, Course NumberTextbook Adoption Application Guide Entering the Application ............................................................................................................ 3 Search with Academic Criteria

  19. Metallic halide lights and lighting systems. (Latest citations from the US Patent Bibliographic file with exemplary claims). Published Search

    SciTech Connect (OSTI)

    Not Available

    1994-11-01T23:59:59.000Z

    The bibliography contains citations of selected patents concerning the design and operation of metallic halide lights and lighting systems. High pressure, high intensity, and low wattage discharge lamps are described. Citations discuss power sources, lamp life, lamp control circuits, thermal switches, and heat reflective coatings. Applications in sport stadium lighting, vehicle headlights, and crop-lighting are included. (Contains a minimum of 170 citations and includes a subject term index and title list.)

  20. Prospects for HTS applications

    SciTech Connect (OSTI)

    Gamble, B.B.; Snitchler, G.L.; Schwall, R.E. [American Superconductor Corp., Westborough, MA (United States)] [American Superconductor Corp., Westborough, MA (United States)

    1996-07-01T23:59:59.000Z

    High temperature superconductor (HTS) wire is rapidly maturing into a working material being produced in ever larger quantities and being used in more significant demonstrations and prototypes. Conductor is now produced routinely in several hundred meter lengths with reproducible results. Current density has progressed to a level suitable for demonstration of many applications. Wire strength has improved and large prototypes fabricated or under consideration using HTS include Superconducting Magnetic Energy Storage (SMES), rotating electrical machines including synchronous ac and dc homopolar motors and drives, generators and condensers, underground transmission cables, utility distribution equipment such as transformers and current limiters, commercial processing applications such as magnetic separation, and specialty magnets such as high field inserts. In this paper the requirements, progress toward these requirements, and the prospects for the future are reviewed.