Powered by Deep Web Technologies
Note: This page contains sample records for the topic "kw billing demand" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Beyond kWh and kW demand: Understanding the new real-time electric...  

NLE Websites -- All DOE Office Websites (Extended Search)

Beyond kWh and kW demand: Understanding the new real-time electric power measurement system in LBNL Building 90 Speaker(s): Alex McEachern Date: January 14, 2010 - 12:00pm...

2

Open Automated Demand Response Dynamic Pricing Technologies and Demonstration  

E-Print Network (OSTI)

if the customer’s maximum demand has exceeded 999 kilowattswhose meter indicates a maximum demand of 200 kW or greater2) the customer's maximum billing demand has exceeded 499

Ghatikar, Girish

2010-01-01T23:59:59.000Z

3

Beyond kWh and kW demand: Understanding the new real-time electric power  

NLE Websites -- All DOE Office Websites (Extended Search)

Beyond kWh and kW demand: Understanding the new real-time electric power Beyond kWh and kW demand: Understanding the new real-time electric power measurement system in LBNL Building 90 Speaker(s): Alex McEachern Date: January 14, 2010 - 12:00pm Location: 90-3122 In the Summer of 2009, LBNL researchers installed end-use sub-metering equipment and associated Energy Information System (EIS) tools to characterize energy use and comfort in Building 90. Seven of 40 key electric loads were measured using advanced meters that make sophisticated real-time measurements of dozens of power flow parameters, power disturbances, and harmonics. The talk will review some electrical engineering fundamentals, how use and interpret data measured in building 90 in real-time. The real-time data available includes power, volt-amps, VAR's, unbalance voltage and current, voltage and current distortion,

4

Electrical Demand Management  

E-Print Network (OSTI)

The Demand Management Plan set forth in this paper has proven to be a viable action to reduce a 3 million per year electric bill at the Columbus Works location of Western Electric. Measures are outlined which have reduced the peak demand 5% below the previous year's level and yielded $150,000 annual savings. These measures include rescheduling of selected operations and demand limiting techniques such as fuel switching to alternate power sources during periods of high peak demand. For example, by rescheduling the startup of five heat treat annealing ovens to second shift, 950 kW of load was shifted off peak. Also, retired, non-productive steam turbine chillers and a diesel air compressor have been effectively operated to displaced 1330 kW during peak periods each day. Installed metering devices have enabled the recognition of critical demand periods. The paper concludes with a brief look at future plans and long range objectives of the Demand Management Plan.

Fetters, J. L.; Teets, S. J.

1983-01-01T23:59:59.000Z

5

Solar Energy Grid Integration Systems. Final Report of the Princeton Power Systems Development of the 100kW Demand Response Inverter.  

DOE Green Energy (OSTI)

Initiated in 2008, the Solar Energy Grid Integration (SEGIS) program is a partnership involving the U.S. Department of Energy, Sandia National Laboratories, electric utilities, academic institutions and the private sector. Recognizing the need to diversify the nation's energy portfolio, the SEGIS effort focuses on specific technologies needed to facilitate the integration of large-scale solar power generation into the nation's power grid Sandia National Laboratories (SNL) awarded a contract to Princeton Power Systems, Inc., (PPS) to develop a 100kW Advanced AC-link SEGIS inverter prototype under the Department of Energy Solar Energy Technologies Program for near-term commercial applications. This SEGIS initiative emphasizes the development of advanced inverters, controllers, communications and other balance-of-system components for photovoltaic (PV) distributed power applications. The SEGIS Stage 3 Contract was awarded to PPS on July 28, 2010. PPS developed and implemented a Demand Response Inverter (DRI) during this three-stage program. PPS prepared a 'Site Demonstration Conference' that was held on September 28, 2011, to showcase the cumulative advancements. This demo of the commercial product will be followed by Underwriters Laboratories, Inc., certification by the fourth quarter of 2011, and simultaneously the customer launch and commercial production sometime in late 2011 or early 2012. This final report provides an overview of all three stages and a full-length reporting of activities and accomplishments in Stage 3.

Bower, Ward Isaac; Heavener, Paul (Princeton Power Systems, Inc., Princeton, NJ); Sena-Henderson, Lisa; Hammell, Darren (Princeton Power Systems, Inc., Princeton, NJ); Holveck, Mark (Princeton Power Systems, Inc., Princeton, NJ); David, Carolyn; Akhil, Abbas Ali; Gonzalez, Sigifredo

2012-01-01T23:59:59.000Z

6

Solar Energy Grid Integration Systems. Final Report of the Princeton Power Systems Development of the 100kW Demand Response Inverter.  

SciTech Connect

Initiated in 2008, the Solar Energy Grid Integration (SEGIS) program is a partnership involving the U.S. Department of Energy, Sandia National Laboratories, electric utilities, academic institutions and the private sector. Recognizing the need to diversify the nation's energy portfolio, the SEGIS effort focuses on specific technologies needed to facilitate the integration of large-scale solar power generation into the nation's power grid Sandia National Laboratories (SNL) awarded a contract to Princeton Power Systems, Inc., (PPS) to develop a 100kW Advanced AC-link SEGIS inverter prototype under the Department of Energy Solar Energy Technologies Program for near-term commercial applications. This SEGIS initiative emphasizes the development of advanced inverters, controllers, communications and other balance-of-system components for photovoltaic (PV) distributed power applications. The SEGIS Stage 3 Contract was awarded to PPS on July 28, 2010. PPS developed and implemented a Demand Response Inverter (DRI) during this three-stage program. PPS prepared a 'Site Demonstration Conference' that was held on September 28, 2011, to showcase the cumulative advancements. This demo of the commercial product will be followed by Underwriters Laboratories, Inc., certification by the fourth quarter of 2011, and simultaneously the customer launch and commercial production sometime in late 2011 or early 2012. This final report provides an overview of all three stages and a full-length reporting of activities and accomplishments in Stage 3.

Bower, Ward Isaac; Heavener, Paul (Princeton Power Systems, Inc., Princeton, NJ); Sena-Henderson, Lisa; Hammell, Darren (Princeton Power Systems, Inc., Princeton, NJ); Holveck, Mark (Princeton Power Systems, Inc., Princeton, NJ); David, Carolyn; Akhil, Abbas Ali; Gonzalez, Sigifredo

2012-01-01T23:59:59.000Z

7

Bill Abolt  

NLE Websites -- All DOE Office Websites (Extended Search)

Abolt Director Shaw Environmental Bill Abolt has been a leader in developing the market for energy efficiency and green initiatives in the greater Chicago Area. He was Mayor...

8

Driving Demand for Home Energy Improvements: Motivating residential customers to invest in comprehensive upgrades that eliminate energy waste, avoid high utility bills, and spur the economy  

Science Conference Proceedings (OSTI)

Policy makers and program designers in the U.S. and abroad are deeply concerned with the question of how to scale up energy efficiency to a level that is commensurate both to the scale of the energy and climate challenges we face, and to the potential for energy savings that has been touted for decades. When policy makers ask what energy efficiency can do, the answers usually revolve around the technical and economic potential of energy efficiency - they rarely hone in on the element of energy demand that matters most for changing energy usage in existing homes: the consumer. A growing literature is concerned with the behavioral underpinnings of energy consumption. We examine a narrower, related subject: How can millions of Americans be persuaded to divert valued time and resources into upgrading their homes to eliminate energy waste, avoid high utility bills, and spur the economy? With hundreds of millions of public dollars flowing into incentives, workforce training, and other initiatives to support comprehensive home energy improvements, it makes sense to review the history of these programs and begin gleaning best practices for encouraging comprehensive home energy improvements. Looking across 30 years of energy efficiency programs that targeted the residential market, many of the same issues that confronted past program administrators are relevant today: How do we cost-effectively motivate customers to take action? Who can we partner with to increase program participation? How do we get residential efficiency programs to scale? While there is no proven formula - and only limited success to date with reliably motivating large numbers of Americans to invest in comprehensive home energy improvements, especially if they are being asked to pay for a majority of the improvement costs - there is a rich and varied history of experiences that new programs can draw upon. Our primary audiences are policy makers and program designers - especially those that are relatively new to the field, such as the over 2,000 towns, cities, states, and regions who are recipients of American Reinvestment and Recovery Act funds for clean energy programs. This report synthesizes lessons from first generation programs, highlights emerging best practices, and suggests methods and approaches to use in designing, implementing, and evaluating these programs. We examined 14 residential energy efficiency programs, conducted an extensive literature review, interviewed industry experts, and surveyed residential contractors to draw out these lessons.

Fuller, Merrian C.

2010-09-20T23:59:59.000Z

9

Cut Your Power Bills  

E-Print Network (OSTI)

Electric power bills can often be reduced by careful attention to the inter-relationship between your plant operations and the electric rate schedule on which your bill is based. The pattern of use of electricity by your plant over a given time span is called its load profile. A continuous process operating 365 days a year would have a flat profile whether measured on a daily, weekly, monthly or yearly basis. But most plant profiles ere not flat because operations may not be consistent for three shifts a day, seven days a week, all year. Profile characteristics of interest to your utility are maximum demand, load factor, time of demand peaks and valleys and power factor. After discussing each of these characteristics below, we will discuss how electric rate schedules are designed, how they are analyzed, and where you can look for possible savings.

Greenwood, R. W.

1979-01-01T23:59:59.000Z

10

Price Responsive Demand in New York Wholesale Electricity Market using OpenADR  

E-Print Network (OSTI)

charges to avoid high electricity bills. Demand Responseaffect customers' electricity bills negatively. Therefore,charges to avoid high electricity bills Under ConEd's SC-9

Kim, Joyce Jihyun

2013-01-01T23:59:59.000Z

11

Bill Vogel  

NLE Websites -- All DOE Office Websites (Extended Search)

and Vantage Point Ventures. His areas of interest and area of expertise is renewable smart grids, or the unified management of distributed energy resources and demand response...

12

Bill Kelly  

NLE Websites -- All DOE Office Websites (Extended Search)

Lab staff member. This Speaker's Seminars Volatile Energy Costs and the Floundering Deregulation of Electricity: A Fresh Look at Integrating Supply-Side and Demand-Side Resources...

13

Bill Vogel  

NLE Websites -- All DOE Office Websites (Extended Search)

Vogel Vogel Director of Apparent Inc, Founder of Trilliant Inc. Apparent Inc. and Trilliant Inc. This speaker was a visiting speaker who delivered a talk or talks on the date(s) shown at the links below. This speaker is not otherwise associated with Lawrence Berkeley National Laboratory, unless specifically identified as a Berkeley Lab staff member. In addition to serving on Apparent's board, Mr. William Vogel is a serial entrepreneur in renewables, smart grid and demand response. He was the founder and CEO of Trilliant Inc., a network that integrates real-time distribution networks with smart metering, demand response and customer information management. Trilliant is owned by a consortium of investors of which include ABB, GE, Mission Point Capital and Vantage Point

14

H. R. 4604: a bill to promote competition in the natural gas market, to ensure open access to transportation service, to encourage production of natural gas, to provide natural gas consumers with adequate supplies at reasonable prices, to eliminate demand restraints, and for other purposes. Introduced in the House of Representatives, Ninety-Ninth Congress, Second Session, April 16, 1986  

Science Conference Proceedings (OSTI)

The Natural Gas Policy Act Amendments of 1986 promotes competition in the natural gas market. Title I ensures open access to transportation service by requiring that interstate pipelines not discriminate in providing transportation services. Title II encourages production of natural gas by removing wellhead price controls and repealing jurisdiction over first sales. Title III provides natural gas consumers with adequate supplies at reasonable prices and eliminates demand restraints. The bill was referred to the House Committee on Energy and Commerce.

Not Available

1986-01-01T23:59:59.000Z

15

omnibus appropriations bill likely  

Science Conference Proceedings (OSTI)

The outlook for spending bills is much like recent years, in which the House and Senate could not complete the normal process of each passing appropriations ...

16

Bill Bradbury Jennifer Anders  

E-Print Network (OSTI)

Idaho James A. Yost Idaho Pat Smith Montana Tom Karier Washington Phil Rockefeller Washington September Anders Vice Chair Montana Henry Lorenzen Oregon W. Bill Booth Idaho James A. Yost Idaho Pat Smith Montana

17

Rhonda Whiting Bill Bradbury  

E-Print Network (OSTI)

Idaho W. Bill Booth Idaho Henry Lorenzen Oregon Tom Karier Washington Phil Rockefeller Washington August Carrier, U.S. Fish and Wildlife Service; Paul Kline, Idaho Department of Fish and Game; and Sue Ireland, Kootenai Tribe of Idaho, will discuss the recent budget and project management practices letters sent

18

Optimal Technology Investment and Operation in Zero-Net-Energy Buildings with Demand Response  

E-Print Network (OSTI)

electricity ($/kWh) demand ($/kW) natural gas 0.035 forelectricity ($/kWh) demand ($/kW) natural gas $/kWh $/thermnatural gas tariff combined with the almost constant demand

Stadler, Michael

2009-01-01T23:59:59.000Z

19

Estimating Large-Customer Demand Response Market Potential: Integrating Price and Customer Behavior  

E-Print Network (OSTI)

reductions in their class peak demand in response to pricesresidential customers with peak demand greater than 350 kWs) Eligible Customers (peak demand) > 1,500 kW > 2000 kW >

Goldman, Charles; Hopper, Nicole; Bharvirkar, Ranjit; Neenan, Bernie; Cappers, Peter

2007-01-01T23:59:59.000Z

20

A Methodology for Estimating Large-Customer Demand Response Market Potential  

E-Print Network (OSTI)

reductions in their class peak demand in response to pricesresidential customers with peak demand greater than 350 kWs) Eligible Customers (peak demand) > 1,500 kW > 2000 kW

Goldman, Charles; Hopper, Nicole; Bharvirkar, Ranjit; Neenan, Bernie; Cappers, Peter

2008-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "kw billing demand" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

SOFCSOFC (10kW(10kW )) Stack Stack ( )  

E-Print Network (OSTI)

& Mitsubishi (band ) 150 kW module Rolls-Royce () 100kW SOFC TOTO, Kyushu () 20kW stack wet process #12;2 SOFC () Mitsubishi Heavy Ind. § SIS § 250kW § 55% Rolls-Royce § SIS § 250kW (micro GT-SOFC) § 53% (125 kW ) Tokyo Gas § SIS § kW (5kW ) / #12

Hong, Deog Ki

22

Data:39375e1d-8451-4736-b0f4-9335c66ddc60 | Open Energy Information  

Open Energy Info (EERE)

of one year. Demand Charge ... 8.20 per KW of billed on-peak demand Distribution Demand Charge ... 1.25 per KW of customer demand...

23

Data:45b3ab8e-e1e8-420a-9ea6-9004cafce801 | Open Energy Information  

Open Energy Info (EERE)

75 kW Sector: Description: *Minimum Charge: 5.00 per KW per billing period of 12 month maximum demand Demand Charges: 7.75 per KW per billing period of averaged seasonal demand...

24

Category:Billings, MT | Open Energy Information  

Open Energy Info (EERE)

MT MT Jump to: navigation, search Go Back to PV Economics By Location Media in category "Billings, MT" The following 16 files are in this category, out of 16 total. SVFullServiceRestaurant Billings MT NorthWestern Corporation.png SVFullServiceRestauran... 64 KB SVHospital Billings MT NorthWestern Corporation.png SVHospital Billings MT... 62 KB SVLargeHotel Billings MT NorthWestern Corporation.png SVLargeHotel Billings ... 62 KB SVLargeOffice Billings MT NorthWestern Corporation.png SVLargeOffice Billings... 62 KB SVMediumOffice Billings MT NorthWestern Corporation.png SVMediumOffice Billing... 62 KB SVMidriseApartment Billings MT NorthWestern Corporation.png SVMidriseApartment Bil... 63 KB SVOutPatient Billings MT NorthWestern Corporation.png SVOutPatient Billings ...

25

Test #3, natural gas, HRR=400 KW  

Science Conference Proceedings (OSTI)

*. Bookmark and Share. Reduced Scale Enclosure Fire Images (NIST TN1483). Test #3, Natural Gas, HRR-400 kW.

2012-03-20T23:59:59.000Z

26

Building 9213s earliest history ? Bill Sergeant  

NLE Websites -- All DOE Office Websites (Extended Search)

from Bill Sergeant. Bill's memory is amazing. When I write about the times when Bill was "living the experiences," he often adds valuable content to the history. Such is the case...

27

politics factors into climate bill, too  

Science Conference Proceedings (OSTI)

06/2 - POLITICS FACTORS INTO CLIMATE BILL, TOO. In A 987-page bill, six committees with jurisdiction, a mammoth oil spill to consider, no bipartisan support, ...

28

FARM BILL PROGRAMS Background: Why are Farm Bill Programs Important  

E-Print Network (OSTI)

Farm Bill conservation programs have the potential to proactively restore and conserve wildlife habitat and species, both for species already listed, but more importantly, to prevent additional listings. Farm Bill conservation incentives programs are applicable to all ecosystem types where farming, ranching and forestry still take place. Current programs target about 75 % of the rural landscape, thus a multitude of ecosystem types can be addressed. Additionally, the amount of funding authorized in the 2002 Farm Bill for resource conservation is over $5 billion a year, which dwarfs any other item in the federal budget for resource conservation. A portion of this funding is directly aimed at wildlife habitat or species restoration and conservation activities. Lastly, Farm Bill incentive programs are voluntary and preventative in nature, thereby having the potential to supplement a more regulatory approach. Although most are aimed at improving water quality and stemming soil erosion, Farm Bill conservation programs may have indirect beneficial impacts for wildlife habitat. The Wildlife Habitat Incentives Program, the Wetland Reserve Program, and in some places the Conservation Reserve Enhancement Program, are directed at wildlife habitat for both listed and non-listed species at risk. The primary problem with determining the impacts of Farm Bill programs that

George Boody (l

2004-01-01T23:59:59.000Z

29

from Microsoft's Bill Gates. Summer  

NLE Websites -- All DOE Office Websites (Extended Search)

Power surge (page 2) Developing fuel for next- generation nuclear reactors, with backing from Microsoft's Bill Gates. Summer fun (pages 4-5) All aboard a bus or train and tour Y-12...

30

Florida Residents See Energy Bill Reductions | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Florida Residents See Energy Bill Reductions Florida Residents See Energy Bill Reductions Florida Residents See Energy Bill Reductions January 27, 2010 - 3:42pm Addthis Indiantown, Florida, has a lot of small-town charm. Its 7,000 residents have acres of citrus groves but only one traffic light in the town. It might be small in size, but Indiantown Non-Profit Housing is making quite an impact across its region. This nonprofit weatherizes the homes of qualifying residents free of charge, and demand for its services is on the rise. "One of the best outcomes is that we can hire additional employees" says Director Donna Carman, referring to the $5.2 million in Recovery Act funds Indiantown Non-Profit Housing has received. The staff has more than doubled from five to 16, meaning that Floridians like 72-year-old Edith

31

Coordination of Energy Efficiency and Demand Response  

E-Print Network (OSTI)

Regulatory Commission [FERC] (2008). Assessment of DemandRegulatory Commission [FERC] (2009). A National AssessmentEIS EMCS EMS EPA ESCO ESPC FERC GE HVAC ISO ISO-NE kW kWh MW

Goldman, Charles

2010-01-01T23:59:59.000Z

32

Bill Lewis | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Bill Lewis Bill Lewis About Us Bill Lewis William A. Lewis, Jr. was appointed Deputy Director of the Office of Civil Rights and Diversity in October 2005. Prior to this appointment, Mr. Lewis was named Director, Office of Employee Concerns, as part of a Secretarial Whistleblower initiative on October 1, 1996. The Employee Concerns Office at the United States Department of Energy Headquarters was established to provide the necessary leadership and policy guidance to employee concerns programs at the Department's major facilities. In February 2002, Mr. Lewis was named the National Ombudsman for the Department, a position he held for three years. Prior to these appointments, Mr. Lewis served as the Director of the Office of Science Education Programs. Mr. Lewis joined the Department of Energy in July 1992 and became a member

33

Bill Valdez | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Bill Valdez Bill Valdez About Us Bill Valdez - Principal Deputy Director Mr. Valdez is the Principal Deputy Director of the Office of Economic Impact and Diversity (ED). Mr. Valdez's career with the Department of Energy spans over 17 years, providing him with extensive knowledge in the areas of workforce development, budget planning, diversity and equal opportunity issues, science policy, corporate and strategic planning, and contract management. In his current position, Mr. Valdez plays a pivotal role in setting overall strategic direction for DOE's diversity, minority education, civil rights, and small business initiatives and activities. Mr. Valdez works with Department program offices to develop a corporate funding strategy for minority institutions to ensure that faculty and

34

15 Ways to Save on Your Water Heating Bill | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

15 Ways to Save on Your Water Heating Bill 15 Ways to Save on Your Water Heating Bill 15 Ways to Save on Your Water Heating Bill October 26, 2009 - 3:49pm Addthis Allison Casey Senior Communicator, NREL Sometimes it surprises me to see that the most popular pages on the site are the ones about solar water heaters and demand (or tankless) water heaters. But considering that water heating can account for around 12% of a family's utility bill-the biggest chunk after space heating and cooling-it really shouldn't be that surprising that you want to know how to heat your water more efficiently. Obviously, not everyone is in a position to go out and buy a new water heater, but we can all do something to use less water and save on our bills. Whether you're looking for no-cost habit changes, low-cost purchases or

35

Average summer electric power bills expected to be lowest in four years  

U.S. Energy Information Administration (EIA) Indexed Site

summer electric power bills expected to be lowest in summer electric power bills expected to be lowest in four years The average U.S. household is expected to pay $395 for electricity this summer. That's down 2.5% from last year and the lowest residential summer power bill in four years, according to the new forecast from the U.S. Energy Information Administration. Lower electricity use to meet cooling demand this summer because of forecasted milder temperatures compared with last summer is expected to more than offset higher electricity prices. The result is lower power bills for most U.S. households during the June, July, and August period. However electricity use and prices vary by region. EIA expects residential power bills will be lower in all areas of the country... except for the West South Central region, which includes

36

Section I: FUEL BILLS - Energy Information Administration  

U.S. Energy Information Administration (EIA)

Section I: FUEL BILLS I-1 In this interview you have told me how your household uses energy. ... What portion of the electric bill is for non-household uses?

37

Demand Response  

NLE Websites -- All DOE Office Websites (Extended Search)

Peak load diagram Demand Response Demand Response (DR) is a set of time-dependent activities that reduce or shift electricity use to improve electric grid reliability, manage...

38

Demand Response  

NLE Websites -- All DOE Office Websites (Extended Search)

Peak load diagram Demand Response Demand response (DR) is a set of time-dependent activities that reduce or shift electricity use to improve electric grid reliability, manage...

39

Regression Models for Demand Reduction based on Cluster Analysis of Load Profiles  

E-Print Network (OSTI)

ESCRIPTIVE S TATISTICS Maximum Demand (kW) Num. of Obs. Meanrate and customer’s maximum demand. C’ i, t : a constant, Arate and customer’s maximum demand. The load sensitivity to

Kiliccote, Sila

2010-01-01T23:59:59.000Z

40

Demand Shifting with Thermal Mass in Large Commercial Buildings in a California Hot Climate Zone  

E-Print Network (OSTI)

period difference in maximum demand was 166 kilowatts (kW).4 p.m. ; however, the maximum demand was not reduced as muchdata indicate that the maximum demand shed always appears

Xu, Peng

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "kw billing demand" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Estimating Demand Response Market Potential Among Large Commercial and Industrial Customers: A Scoping Study  

E-Print Network (OSTI)

size (average maximum demand) 84 , business type (SIC code),HECO customers’ average maximum demands was not available.to estimate the maximum demand (kW) of each customer.

Goldman, Charles; Hopper, Nicole; Bharvirkar, Ranjit; Neenan, Bernie; Cappers, Peter

2007-01-01T23:59:59.000Z

42

Addressing Energy Demand through Demand Response: International...  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy Demand through Demand Response: International Experiences and Practices Title Addressing Energy Demand through Demand Response: International Experiences and Practices...

43

Addressing Energy Demand through Demand Response: International...  

NLE Websites -- All DOE Office Websites (Extended Search)

Addressing Energy Demand through Demand Response: International Experiences and Practices Title Addressing Energy Demand through Demand Response: International Experiences and...

44

Impact of a solar domestic hot water demand-side management program on an electric utility and its customers  

DOE Green Energy (OSTI)

A methodology to assess the economic and environmental impacts of a large scale implementation of solar domestic hot water (SDHW) systems is developed. Energy, emission and demand reductions and their respective savings are quantified. It is shown that, on average, an SDHW system provides an energy reduction of about 3200 kWH, avoided emissions of about 2 tons and a capacity contribution of 0.7 kW to a typical Wisconsin utility that installs 5000 SDHW system. The annual savings from these reductions to utility is {dollar_sign}385,000, providing a return on an investment of over 20{percent}. It is shown that, on average, a consumer will save {dollar_sign}211 annually in hot water heating bills. 8 refs., 7 figs.

Trzeniewski, J.; Mitchell, J.W.; Klein, S.A.; Beckman, W.A.

1996-09-01T23:59:59.000Z

45

When Utility Bills Attack! | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

When Utility Bills Attack! When Utility Bills Attack! When Utility Bills Attack! March 1, 2010 - 11:05am Addthis Amy Foster Parish It may come as a shock to my college math professor, but where my family's finances are concerned, I'm a budgeter. Just before a new month begins, I take some time to plan for the month's regular bills as well as any special events or holidays that might require setting some extra money aside. I even have a special notebook to track all this financial data (and shopping for a new notebook every year is half the fun of fiscal responsibility). But as proactive as I am with my monthly budgeting, I tend to be reactive when it comes to my monthly utility bills. I take a guess at what my bill will be at the beginning of the month, and then I'm either excited when the

46

Net Energy Billing | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Billing Energy Billing Net Energy Billing < Back Eligibility Agricultural Commercial Industrial Institutional Low-Income Residential Multi-Family Residential Nonprofit Residential Schools Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Solar Home Weatherization Wind Program Info State Maine Program Type Net Metering Provider Maine Public Utilities Commission All of Maine's electric utilities -- investor-owned utilities (IOUs), consumer-owned utilities (COUs), which include municipal utilities and electric cooperatives -- must offer net energy billing for individual customers. Furthermore IOUs are required to offer net metering for shared ownership customers, while COUs may offer net metering to shared ownership

47

Q&A with Bill Christie  

Science Conference Proceedings (OSTI)

Catherine Watkins, associate editor of inform, recently posed a series of questions to the creator of The Lipid Library, William W. Christie Q&A with Bill Christie ...

48

PIA - FBI Billing System | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

& Publications PIA - Security Clearance Work Tracking and Budget System Office of Personnel Management (OPM) Billing System PIA, Office of Health, Safety and Security TRAIN-PIA.pdf...

49

Alternative Underwriting Criteria - Using Utility Bill Payment...  

NLE Websites -- All DOE Office Websites (Extended Search)

Alternative Underwriting Criteria - Using Utility Bill Payment History as a Proxy for Credit: Case Study on Clean Energy Works Oregon Title Alternative Underwriting Criteria -...

50

Estimation of Demand Responses to Ramp Meters  

E-Print Network (OSTI)

Estimation of Demand Responses to Ramp Meters by Lei Zhang and David Levinson For the 3rd ICTTS different types of trips respond to ramp meters (work vs. non-work; short vs. long) A bill was passed to shut off ramp meters to study effectiveness in the Twin Cities in Spring 2000 The shut-off experiment

Levinson, David M.

51

DESIGN STUDY OF A NUCLEAR POWER PLANT FOR 100-KW ELECTRIC AND 400-KW HEAT CAPACITY  

SciTech Connect

A conceptional design study was made of a lowpower ''package'' reactor plant for the production of 100 kw of electrical power and 400 kw of heat at remote Arctic installations. The power plant steam generator is proposed to be an unmanned, heterogeneous, boilingtype reactor capable of continuous operation for extended periods. The design is based on data derived from experiments with boiling-type reactors conducted by Argorne at the Reactor Testing Station, Arco, Idaho.

Treshow, M.; Snider, A.R.; Shaftman, D.H.

1955-05-01T23:59:59.000Z

52

The Honorable Bill Johnson j.  

Office of Legacy Management (LM)

- Department of En&gy, - Department of En&gy, Washington, DC 20585 \APR 0 3 7995 The Honorable Bill Johnson j. 30 Church Street, Rochester, New-York 14614 / Dear MayorJohnson: 'I Secretary of Energy Hazel O'Leary has announced a'nei approach to openness in the Department of'Energy (DDE) and its communications with the public. In, support of this initiative, we are pleased to forward the enclosed info&tion related to the former University of. Rochester site in, your jurisdiction performed work for DOE or its predecessor agencies. Thins information is provided for your information, use, and retqntion. DDE's Formerly Utilized SitesRemedial Action Program.isI responsible for identification of sites used by DOE's predecessor agencies, determining current 'radiological condition.'and, where, it has authority, performing

53

Reducing the Federal Energy Bill  

NLE Websites -- All DOE Office Websites (Extended Search)

1 1 Reducing the Federal Energy Bill Berkeley Lab's Work with the Federal Energy Management Program It costs billions of dollars and uses more energy than any other entity in the United States. What is it? Answer: the Federal government. In fiscal year 1995, the Federal government spent $8 billion on a net energy consumption of 1.15 quadrillion BTUs. While that may be a lot of energy in absolute terms, the numbers have been improving for years. Compared with fiscal year 1985, the 1995 energy-use figure is down by 22.5%, and the costs are down $2.5 billion. The decline is explained in part by the activities of FEMP (the Federal Energy Management Program) and the efforts of energy-efficiency experts at national laboratories, such as those at Berkeley Lab's Environmental Energy

54

Senate Bill (SB) 1305 - Power Marketing - Sierra Nevada Region...  

NLE Websites -- All DOE Office Websites (Extended Search)

Senate Bill 1305 Senate Bill 1305 State Senate Bill 1305 is a mandate that requires suppliers of energy to report their sources of generation under certain conditions. Munis must...

55

Using QECBs for Public Building Upgrades: Reducing Energy Bills...  

NLE Websites -- All DOE Office Websites (Extended Search)

Public Building Upgrades: Reducing Energy Bills in the City of Philadelphia Title Using QECBs for Public Building Upgrades: Reducing Energy Bills in the City of Philadelphia...

56

Table 5B. Commercial Average Monthly Bill by Census Division ...  

U.S. Energy Information Administration (EIA)

Home > Electricity > Electric Sales, Revenue, and Price > Commercial Average Monthly Bill by Census Division, and State: Table 5B. Commercial Average Monthly Bill by ...

57

Money for Research, Not for Energy Bills: Finding Energy and...  

NLE Websites -- All DOE Office Websites (Extended Search)

Not for Energy Bills: Finding Energy and Cost Savings in High Performance Computer Facility Designs Title Money for Research, Not for Energy Bills: Finding Energy and Cost...

58

Commercial & Industrial Demand Response Within Hawaiian Electric Company Service Territory  

Science Conference Proceedings (OSTI)

By reducing power usage during peak demand periods, demand response (DR) programs can help utilities manage power loads and complement energy efficiency activities while providing ratepayers an opportunity to substantially reduce their electric bills. This project assessed the costs and benefits of potential DR programs for Hawaiian Electric Company's (HECO's) commercial and industrial (CI) customers.

2007-06-04T23:59:59.000Z

59

Property:Incentive/WindResMaxKW | Open Energy Information  

Open Energy Info (EERE)

search Property Name IncentiveWindResMaxKW Property Type String Description The maximum installed residential wind capacity in kW that is eligible for a rebate. Ex: The maximum...

60

Property:Incentive/PVComDolKW | Open Energy Information  

Open Energy Info (EERE)

Name IncentivePVComDolKW Property Type String Description The amount per kW of installed capacity of a commercial PV system disbursed as an upfront incentive. Ex: MN's...

Note: This page contains sample records for the topic "kw billing demand" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Property:Incentive/PVResDolKW | Open Energy Information  

Open Energy Info (EERE)

Name IncentivePVResDolKW Property Type String Description The amount per kW of installed capacity of a residential PV system disbursed as an upfront incentive. Ex: MD's...

62

Property:Incentive/WindComMaxKW | Open Energy Information  

Open Energy Info (EERE)

search Property Name IncentiveWindComMaxKW Property Type String Description The maximum installed commercial wind capacity in kW that is eligible for a rebate. This also applies...

63

Property:Incentive/PVComMaxKW | Open Energy Information  

Open Energy Info (EERE)

search Property Name IncentivePVComMaxKW Property Type String Description The maximum installed commercial PV capacity in kW that is eligible for a rebate. This also applies to...

64

Property:Incentive/PVResMaxKW | Open Energy Information  

Open Energy Info (EERE)

search Property Name IncentivePVResMaxKW Property Type String Description The maximum installed residential PV capacity in kW that is eligible for a rebate. CT's maximum...

65

Property:Incentive/WindResDolKW | Open Energy Information  

Open Energy Info (EERE)

Name IncentiveWindResDolKW Property Type String Description The amount per kW of installed capacity of a residential wind system disbursed as an upfront incentive. Ex:...

66

Property:Incentive/WindComDolKW | Open Energy Information  

Open Energy Info (EERE)

Name IncentiveWindComDolKW Property Type String Description The amount per kW of installed capacity of a commercial wind system disbursed as an upfront incentive. Ex: OR's...

67

Evaluatoni of Automated Utility Bill Calibration Methods  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. Evaluation of Automated Utility Bill Calibration Methods BA Technical Update Meeting Ben Polly, Joe Robertson 04/30/13 Utility Bill Calibration * "Calibrate" or "true-up" building energy models to utility bill data to increase the accuracy of retrofit savings predictions * Calibration methods typically involve adjusting input parameters * Predict retrofit savings using the adjusted (calibrated) model 2 Background: BESTEST-EX * BESTEST-EX is a suite for testing calibration methods and retrofit savings predictions associated with audit software * Field trials showed that:

68

Bill Nye (Energy All Stars Presentation)  

Energy.gov (U.S. Department of Energy (DOE))

Bill Nye the Science Guy delivered this presentation on space and the lessons about climate change that can be gleaned from the other planets in our solar system at the Energy All Stars event on...

69

Energy Secretary Bodman's Statement on House Passage of the Energy Bill |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Bodman's Statement on House Passage of the Energy Bodman's Statement on House Passage of the Energy Bill Energy Secretary Bodman's Statement on House Passage of the Energy Bill July 28, 2005 - 2:29pm Addthis WASHINGTON, DC - Secretary of Energy Samuel W. Bodman today released the following statement regarding House passage of the Energy Policy Act of 2005: "Ensuring America's future energy security has been a priority for President Bush since his early days in office, and I commend the House of Representatives, particularly Chairman Barton and Ranking Member Dingell, for their efforts on this broad-based legislation that helps achieve that goal. Because of the hard work and thoughtful approach that went into crafting this bipartisan legislation, the House has passed a bill that will reduce energy demand, increase energy supplies, and update our aging energy

70

EnergySolve Demand Response | Open Energy Information  

Open Energy Info (EERE)

EnergySolve Demand Response EnergySolve Demand Response Jump to: navigation, search Name EnergySolve Demand Response Place Somerset, New Jersey Product Somerset-based utility bill outsourcing company that provides electronic utility bill auditing, tariff analysis, late fee avoidance, and flexible bill payment solutions. Coordinates 45.12402°, -92.675379° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":45.12402,"lon":-92.675379,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

71

Property:Incentive/PVPbiFitMaxKW | Open Energy Information  

Open Energy Info (EERE)

PVPbiFitMaxKW PVPbiFitMaxKW Jump to: navigation, search Property Name Incentive/PVPbiFitMaxKW Property Type String Description The maximum installed PV capacity in kW that is eligible for the PBI or FIT. Ex: We Energies' FIT maximum eligible PV system size is 100 kW. Format: 100.0 [1] References ↑ DSIRE Pages using the property "Incentive/PVPbiFitMaxKW" Showing 25 pages using this property. (previous 25) (next 25) A Alliant Energy (Wisconsin Power and Light) - Advanced Renewables Tariff (Wisconsin) + 20 + Ameren Missouri - Solar Renewable Energy Credits + 100 + Anaheim Public Utilities - PV Buydown Program (California) + 1000 + Austin Energy - Commercial PV Incentive Program (Texas) + 20 + Austin Energy - Value of Solar Residential Rate (Texas) + 20 +

72

Transportation Demand  

Gasoline and Diesel Fuel Update (EIA)

page intentionally left blank page intentionally left blank 69 U.S. Energy Information Administration | Assumptions to the Annual Energy Outlook 2011 Transportation Demand Module The NEMS Transportation Demand Module estimates transportation energy consumption across the nine Census Divisions (see Figure 5) and over ten fuel types. Each fuel type is modeled according to fuel-specific technology attributes applicable by transportation mode. Total transportation energy consumption is the sum of energy use in eight transport modes: light-duty vehicles (cars and light trucks), commercial light trucks (8,501-10,000 lbs gross vehicle weight), freight trucks (>10,000 lbs gross vehicle weight), buses, freight and passenger aircraft, freight and passenger rail, freight shipping, and miscellaneous

73

300kW Energy Storage Demonstration Project  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

kW Energy Storage Demonstration Project Technical Overview Presented at: Annual Doe Peer Review Meeting 2008 DOE Energy Storage & Power Electronics Research Programs By Ib I....

74

Stakeholder Engagement and Outreach: USDA Farm Bill State Workshop  

Wind Powering America (EERE)

Rural Rural Communities Printable Version Bookmark and Share Agricultural & Rural Farm Bill Outreach Articles Wind for Homeowners, Farmers, & Businesses Wind Farms Resources & Tools Native Americans USDA Farm Bill State Workshop Materials The Farm Bill presentations below were used at four Farm Bill Workshops in Montana, February 2004. We encourage state wind working groups to use the presentations below in their state workshops to help farmers, ranchers, and rural small businesses take advantage of the USDA Farm Bill (Section 9006) grants for renewable energy projects. These presentations will help those interested in developing wind projects to organize, write, and submit an application for funding assistance under the Farm Bill. Introduction to Wind Energy Applications

75

Senate Bill No. 1 CHAPTER 132  

E-Print Network (OSTI)

, Murray. Electricity: solar energy: net metering. (1) Existing law requires the State Energy Resources sources of energy, including solar resources. Existing law requires the Energy Commission to develop of solar energy and to provide maximum information to the public concerning solar devices. This bill would

76

Advanced Billing and Customer Specification Requirements  

Science Conference Proceedings (OSTI)

The ability to bill and serve customers well will be key to whether an energy company ultimately succeeds in the emerging retail marketplace. This document provides the essential planning and implementation framework needed by an energy company to reconstruct its back-office to meet these objectives.

1997-09-24T23:59:59.000Z

77

Assembly Bill No. 1632 CHAPTER 722  

E-Print Network (OSTI)

capability both in and out of state, natural gas interstate and intrastate pipeline capacity, storage and use the commission, in its report, to consider electricity and natural gas forecasting and assessment activities, as specified, in reporting on electricity and natural gas markets. This bill would require the commission

78

Customer Risk from Real-Time Retail Electricity Pricing: Bill Volatility and Hedgability  

E-Print Network (OSTI)

the ?uctuations in electricity bills that are conceivable.concern about analyzing electricity bill volatility of largeat a The issue of electricity bill volatility from RTP

Borenstein, Severin

2007-01-01T23:59:59.000Z

79

Demand Response  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Assessment for Eastern Interconnection Youngsun Baek, Stanton W. Hadley, Rocio Martinez, Gbadebo Oladosu, Alexander M. Smith, Fran Li, Paul Leiby and Russell Lee Prepared for FY12 DOE-CERTS Transmission Reliability R&D Internal Program Review September 20, 2012 2 Managed by UT-Battelle for the U.S. Department of Energy DOE National Laboratory Studies Funded to Support FOA 63 * DOE set aside $20 million from transmission funding for national laboratory studies. * DOE identified four areas of interest: 1. Transmission Reliability 2. Demand Side Issues 3. Water and Energy 4. Other Topics * Argonne, NREL, and ORNL support for EIPC/SSC/EISPC and the EISPC Energy Zone is funded through Area 4. * Area 2 covers LBNL and NREL work in WECC and

80

ARPA-E Announces 2012 Energy Innovation Summit Featuring Bill...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Announces 2012 Energy Innovation Summit Featuring Bill Gates, Fred Smith and Lee Scott ARPA-E Announces 2012 Energy Innovation Summit Featuring Bill Gates, Fred Smith and Lee Scott...

Note: This page contains sample records for the topic "kw billing demand" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Table 5C. Industrial Average Monthly Bill by Census Division ...  

U.S. Energy Information Administration (EIA)

Home > Electricity > Electric Sales, Revenue, and Price > Industrial Average Monthly Bill by Census Division, and State: Table 5C. Industrial ...

82

Billings, Montana: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Billings, Montana: Energy Resources Billings, Montana: Energy Resources Jump to: navigation, search Equivalent URI DBpedia Coordinates 45.7832856°, -108.5006904° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":45.7832856,"lon":-108.5006904,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

83

Billings, Montana: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Billings, MT) Billings, MT) Jump to: navigation, search Equivalent URI DBpedia Coordinates 45.7832856°, -108.5006904° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":45.7832856,"lon":-108.5006904,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

84

Alternatives for reducing hot-water bills  

DOE Green Energy (OSTI)

A two stage approach to reducing residential water heating bills is described. In Stage I, simple conservation measures were included to reduce the daily hot water energy consumption and the energy losses from the water tank. Once these savings are achieved, Stage II considers more costly options for further reducing the water heating bill. Four alternatives are considered in Stage II: gas water heaters; solar water heaters (two types); heat pump water heaters; and heat recovery from a heat pump or air conditioner. To account for variations within the MASEC region, information on water heating in Rapid City, Minneapolis, Chicago, Detroit, and Kansas City is presented in detail. Information on geography, major population centers, fuel prices, climate, and state solar incentives is covered. (MCW)

Bennington, G.E.; Spewak, P.C.

1981-06-01T23:59:59.000Z

85

5-kW Solid Oxide Fuel Cell Case Study  

Science Conference Proceedings (OSTI)

This report chronicles, as a case study, a project in which an Acumentrics 5-kW solid oxide fuel cell was installed at Cuyahoga Valley National Park in Ohio.

2006-03-27T23:59:59.000Z

86

High Temperatures & Electricity Demand  

E-Print Network (OSTI)

High Temperatures & Electricity Demand An Assessment of Supply Adequacy in California Trends.......................................................................................................1 HIGH TEMPERATURES AND ELECTRICITY DEMAND.....................................................................................................................7 SECTION I: HIGH TEMPERATURES AND ELECTRICITY DEMAND ..........................9 BACKGROUND

87

A study of industrial equipment energy use and demand control  

E-Print Network (OSTI)

Demand and duty factors were measured for selected equipment [air compressors, electric furnaces, injection-molding machines, a welder, a granulator (plastics grinder), a sheet metal press and brake, a lathe, a process chiller, and cooling tower pumps and fans] in two industrial plants. Demand factors for heavily loaded air compressors were found to be near 100 %, for lightly loaded centrifugal equipment (lathe, sheet metal shear and brake, and granulator) near 10 %, and for injection-molding machines near 50 %. The measured demand factors differ from those often estimated during energy surveys. Duty factors for some equipment were found to exceed 100 %, showing that some loads were on for longer periods than that indicated by plant personnel. Comparing a detailed summary of equipment rated loads to annual utility bills, when measurements are not available, can prevent over-estimation of the demand and duty factors for a plant. Raw unadjusted estimates of demand factors of 60 % or higher are often made, yet comparisons of rated loads to utility bills show that some equipment demand factors may be 50 % or less. This project tested a simple beacon alerting system, which used a blue strobe light to alert plant personnel when a preset demand limit had been reached. Tests of load shedding verified that the estimated demand savings of 50 kVA were realized (out of a total demand of almost 1200 kVA) when lighting and air conditioning loads were turned off.

Dooley, Edward Scott

2001-01-01T23:59:59.000Z

88

64 kW concentrator Photovoltaics Application Test Center. Volume. Final report  

DOE Green Energy (OSTI)

Kaman Sciences Corporation has designed a 64 kW Concentrating Photovoltaic Applications Test Center (APTEC). The APTEC employs a combined concentrating photovoltaic array in a total energy system application for load sharing the electric and thermal demands of a large computer center with the interfaced electric and natural gas utility. The photovoltaic array is composed of two-axis tracking heliostats of Fresnel lens concentrating, silicon solar cell modules. The modules are cooled with a fluid which transfers heat to a ground coupled heat sink/storage unit for subsequent use in meeting the computer center's thermal load demand. The combined photovoltaic power system shares basic components - a power conditioning unit, batteries and thermal conditioning equipment - with the electric and natural gas utility service, improving the computer center's operating availability time and displacing a portion of the fossil fuel required to power the computer center with solar energy. The detailed system design is reported.

Jardine, D.M.; Jones, D.W.

1980-06-01T23:59:59.000Z

89

DOE: T-O-D rates shift kWh and kW  

SciTech Connect

Technical report:In 1975, FEA, in cooperation with state and local utility authorities, initiated a series of field projects that collected electricity usage data under new electric utility rate designs and load management techniques. Individual projects included a wide range of load-management and electricity rate design alternatives, with emphasis on several forms of time-of-day rates. The program is now funded by the U.S. Dept. of Energy. Objectives of the program, kWh usage effects, kw demand effects, and sources of the load changes are discussed. Initial results indicate actual or effective shifts in electricity consumption from peak to off-peak periods, and reductions in diversified demand coincident with system peaks. (10 graphs)

Johnson, C.R.; Mintz, S.

1978-11-15T23:59:59.000Z

90

Open Automated Demand Response Dynamic Pricing Technologies and Demonstration  

E-Print Network (OSTI)

peak prices) to reduce electricity bill volatility. Smallwith higher or lower electricity bills than desired, since

Ghatikar, Girish

2010-01-01T23:59:59.000Z

91

Apartment Hunting - Part II - Keeping those Energy Bills Down |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

- Part II - Keeping those Energy Bills Down - Part II - Keeping those Energy Bills Down Apartment Hunting - Part II - Keeping those Energy Bills Down August 23, 2010 - 5:17pm Addthis Kyle Rudzinski Special Assistant to the Director of Technology Advancement and Outreach, EERE I recently went looking for a new apartment. And though my parents may say I'm stingy, I like to think I'm economical. Or better yet, I'm a bargain hunter. I asked myself three main questions when looking for my new place: How far is it from public transit and community businesses? Can I keep my energy bills to a minimum? What's the rent? In the second of two entries on apartment hunting, I discuss things to look for that might help keep your energy bills low. When you think about it, energy bills can, in effect, increase your rent

92

Table 5B. Commercial average monthly bill by census division...  

U.S. Energy Information Administration (EIA) Indexed Site

" Census Division " " State ","Number of Consumers "," Average Monthly Consumption (kWh)","Price (Cents per Kilowatthour)","Average Monthly Bill (Dollar and cents)" "New...

93

Table 5A. Residential Average Monthly Bill by Census Division ...  

U.S. Energy Information Administration (EIA)

Table 5A. Residential Average Monthly Bill by Census Division, and State, 2009: Census Division State Number of Consumers Average Monthly Consumption ...

94

Senate Bill No. 1389 CHAPTER 568  

E-Print Network (OSTI)

of trends in electricity and natural gas supply and demand, and the outlook for wholesale and retail prices of the adequacy of electricity and natural gas supplies to meet forecasted demand growth. Assessment and transmission system capacity and use. (4) Evaluation of potential impacts of electricity and natural gas supply

95

Data:9709dfe4-3de5-436d-bc23-6ac8081fc2c1 | Open Energy Information  

Open Energy Info (EERE)

Electric Cooperative where the monthly contract demand is 2500 - 4999 kW with a monthly energy usage equal to or greater than 425 hours per kW of billing demand. Source or...

96

Data:Ee80f738-01ae-4a4d-85f2-9bb35fd9db05 | Open Energy Information  

Open Energy Info (EERE)

Cooperative where the monthly contract demand is 5,000 kW or over, with a monthly energy usage equal to or greater than 425 hours per kW of billing demand. Source or...

97

Data:80f5af0e-7484-41a8-be75-d217fc240997 | Open Energy Information  

Open Energy Info (EERE)

Applicable to contracts with contract demands of 5000 KW or greater with a monthly energy usage equal to or greater than 425 hours per KW of Billing Demand: These contracts...

98

Data:58e4c015-5597-4498-9a68-33d13b7400a9 | Open Energy Information  

Open Energy Info (EERE)

Applicable to contracts with contract demands of 5000 KW or greater with a monthly energy usage equal to or greater than 425 hours per KW of Billing Demand: These contracts...

99

Data:6f3bc140-a7c6-4117-aa4f-fdd035be02dd | Open Energy Information  

Open Energy Info (EERE)

Applicable to contracts with contract demands of 1000 KW or greater with a monthly energy usage equal to or greater than 425 hours per KW of Billing Demand. These contracts...

100

Data:E953e50f-48e7-4689-b3b0-2fda995352f6 | Open Energy Information  

Open Energy Info (EERE)

Applicable to contracts with contract demands of 1000 KW or greater with a monthly energy usage equal to or greater than 425 hours per KW of Billing Demand. These contracts...

Note: This page contains sample records for the topic "kw billing demand" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

E:\BILLS\H6.PP  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

July 14, 2005 July 14, 2005 Ordered to be printed as passed In the Senate of the United States, June 28, 2005. Resolved, That the bill from the House of Representa- tives (H.R. 6) entitled ''An Act to ensure jobs for our future with secure, affordable, and reliable energy.'', do pass with the following AMENDMENT: Strike out all after the enacting clause and insert: SECTION 1. SHORT TITLE; TABLE OF CONTENTS. 1 (a) SHORT TITLE.-This Act may be cited as the ''En- 2 ergy Policy Act of 2005''. 3 2 HR 6 PAP (b) TABLE OF CONTENTS.-The table of contents of this 1 Act is as follows: 2 Sec. 1. Short title; table of contents. Sec. 2. Definitions. TITLE I-ENERGY EFFICIENCY Subtitle A-Federal Programs Sec. 101. Energy and water saving measures in congressional buildings. Sec. 102. Energy management requirements.

102

A leasing instances based billing model for cloud computing  

Science Conference Proceedings (OSTI)

As a new technology in IT industry, cloud computing has been much focused by both academia and industry. And many topics in cloud computing are under study. However, as one of the most important issue, billing and pricing has been not so much concerned. ... Keywords: billing model, cloud computing, leasing instances, pricing

Qin Yuan; Zhixiang Liu; Junjie Peng; Xing Wu; Jiandun Li; Fangfang Han; Qing Li; Wu Zhang; Xinjin Fan; Shengyuan Kong

2011-05-01T23:59:59.000Z

103

Advanced Demand Responsive Lighting  

NLE Websites -- All DOE Office Websites (Extended Search)

Demand Demand Responsive Lighting Host: Francis Rubinstein Demand Response Research Center Technical Advisory Group Meeting August 31, 2007 10:30 AM - Noon Meeting Agenda * Introductions (10 minutes) * Main Presentation (~ 1 hour) * Questions, comments from panel (15 minutes) Project History * Lighting Scoping Study (completed January 2007) - Identified potential for energy and demand savings using demand responsive lighting systems - Importance of dimming - New wireless controls technologies * Advanced Demand Responsive Lighting (commenced March 2007) Objectives * Provide up-to-date information on the reliability, predictability of dimmable lighting as a demand resource under realistic operating load conditions * Identify potential negative impacts of DR lighting on lighting quality Potential of Demand Responsive Lighting Control

104

Transportation Demand This  

Annual Energy Outlook 2012 (EIA)

69 U.S. Energy Information Administration | Assumptions to the Annual Energy Outlook 2012 Transportation Demand Module The NEMS Transportation Demand Module estimates...

105

Demand Response Spinning Reserve  

NLE Websites -- All DOE Office Websites (Extended Search)

Demand Response Spinning Reserve Title Demand Response Spinning Reserve Publication Type Report Year of Publication 2007 Authors Eto, Joseph H., Janine Nelson-Hoffman, Carlos...

106

Addressing Energy Demand  

NLE Websites -- All DOE Office Websites (Extended Search)

Addressing Energy Demand through Demand Response: International Experiences and Practices Bo Shen, Girish Ghatikar, Chun Chun Ni, and Junqiao Dudley Environmental Energy...

107

Propane Sector Demand Shares  

U.S. Energy Information Administration (EIA)

... agricultural demand does not impact regional propane markets except when unusually high and late demand for propane for crop drying combines with early cold ...

108

The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California  

E-Print Network (OSTI)

a direct comparison of electricity bills between customersincludes both bill credits for electricity exported to thethe meter”). Bill credits for PV electricity production in

Darghouth, Naim

2010-01-01T23:59:59.000Z

109

Electrical Demand Control  

E-Print Network (OSTI)

Almost every building owner or manager is interested in controlling electrical costs. Since the HVAC system is a large user of electricity, this article will discuss what can be done in the HVAC system to influence parts of the utility bill.

Eppelheimer, D. M.

1984-01-01T23:59:59.000Z

110

300kW Energy Storage Demonstration Project  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

kW Energy Storage Demonstration kW Energy Storage Demonstration Project Technical Overview Presented at: Annual Doe Peer Review Meeting ─ 2008 DOE Energy Storage & Power Electronics Research Programs By Ib I. Olsen September 29, 2008 116 John Street - Suite 2320 New York, New York 10038 (p) 1.212.732.5507 (f) 1.212.732.5597 www.gaiapowertech.com This project is part of the Joint Energy Storage Initiative between the New York State Energy Research and Development Authority (NYSERDA) and the Energy Storage Systems Program of the U.S. Department of Energy (DOE/ESS), and managed by Sandia National Laboratories (SNL). Sandia is a multi-program laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration, under contract DE-AC04-94AL85000

111

Demand Response and Open Automated Demand Response Opportunities...  

NLE Websites -- All DOE Office Websites (Extended Search)

Demand Response and Open Automated Demand Response Opportunities for Data Centers Title Demand Response and Open Automated Demand Response Opportunities for Data Centers...

112

Addressing Energy Demand through Demand Response: International Experiences and Practices  

E-Print Network (OSTI)

of integrating demand response and energy efficiencyand D. Kathan (2009), Demand Response in U.S. ElectricityFRAMEWORKS THAT PROMOTE DEMAND RESPONSE 3.1. Demand Response

Shen, Bo

2013-01-01T23:59:59.000Z

113

Demand Trading: Building Liquidity  

Science Conference Proceedings (OSTI)

Demand trading holds substantial promise as a mechanism for efficiently integrating demand-response resources into regional power markets. However, regulatory uncertainty, the lack of proper price signals, limited progress toward standardization, problems in supply-side markets, and other factors have produced illiquidity in demand-trading markets and stalled the expansion of demand-response resources. This report shows how key obstacles to demand trading can be overcome, including how to remove the unce...

2002-11-27T23:59:59.000Z

114

Expected annual electricity bill savings for various PPA price options |  

Open Energy Info (EERE)

Expected annual electricity bill savings for various PPA price options Expected annual electricity bill savings for various PPA price options Jump to: navigation, search Impact of Utility Rates on PV Economics Bill savings tables (main section): When evaluating PV systems under a PPA, it is important to look at the net effect on the building's annual electricity expense. If the solar value is greater than the PPA price, then the building will realize a net savings on annual energy expenses. If the solar value is less than the PPA price, then the building will realize a net loss. It is useful to understand how annual electricity expenses will be impacted at various PPA price levels. Bill Savings at PPA price of $0.04/kWhr Bill Savings at PPA price of $0.08/kWhr Bill Savings at PPA price of $0.12/kWhr Retrieved from "http://en.openei.org/w/index.php?title=Expected_annual_electricity_bill_savings_for_various_PPA_price_options&oldid=515464"

115

The Potential Impact of Increased Renewable Energy Penetrations on Electricity Bill Savings from Residential Photovoltaic Systems  

E-Print Network (OSTI)

Penetrations on Electricity Bill Savings from ResidentialPENETRATIONS ON ELECTRICITY BILL SAVINGS FROM RESIDENTIALBill Savings In this paper, we have chosen two compensation mechanisms for electricity

Barbose, Galen

2013-01-01T23:59:59.000Z

116

Omnibus Energy Bill of 2013 (Maine) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Omnibus Energy Bill of 2013 (Maine) Omnibus Energy Bill of 2013 (Maine) Omnibus Energy Bill of 2013 (Maine) < Back Eligibility Agricultural Commercial Construction Developer Fed. Government Fuel Distributor General Public/Consumer Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Low-Income Residential Multi-Family Residential Municipal/Public Utility Nonprofit Residential Retail Supplier Rural Electric Cooperative Schools State/Provincial Govt Systems Integrator Transportation Tribal Government Utility Savings Category Buying & Making Electricity Water Wind Program Info State Maine Program Type Climate Policies Generating Facility Rate-Making Green Power Purchasing Interconnection Line Extension Analysis Loan Program Public Benefits Fund Renewables Portfolio Standards and Goals

117

Draft Measuring the Capacity Impacts of Demand Response to be published in the Electricity Journal – pre-print version  

E-Print Network (OSTI)

Demand response is an increasing part of the energy policy agenda in the United States. The Federal Energy Regulatory Commission (FERC) has undertaken major initiatives to encourage the incorporation of demand response in the wholesale markets, the American Recovery and Reinvestment Act of 2009 (aka, “the stimulus bill”) has provisions

Robert Earle; Edward P. Kahn; Edo Macan

2009-01-01T23:59:59.000Z

118

Senate Bill No. 1565 CHAPTER 692  

E-Print Network (OSTI)

industry supply, production, transportation, delivery and distribution, demand, and prices. The commission, relating to energy conservation and development. [Approved by Governor September 22, 2004. Filed with Secretary of State September 22, 2004.] LEGISLATIVE COUNSEL'S DIGEST SB 1565, Bowen. State Energy Resources

119

Upping Efficiency Standards, Lowering Utility Bills | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Upping Efficiency Standards, Lowering Utility Bills Upping Efficiency Standards, Lowering Utility Bills Upping Efficiency Standards, Lowering Utility Bills September 2, 2010 - 4:17pm Addthis Niketa Kumar Niketa Kumar Public Affairs Specialist, Office of Public Affairs What does this mean for me? Using energy-efficient appliances is one of the easiest and most important ways consumers have to save money. Purchasing energy-efficient appliances is one of the easiest and most important ways consumers have to save money, reduce their electricity consumption and help cut down on carbon pollution. We use appliances every day - to cook our food, cool our homes, heat our water and clean our clothes. In fact, for a typical U.S. family, heating and cooling and water heating account for about 50 percent of utility bills. Home appliances and

120

Consumer Tips for Lowering Your Utility Bill | Open Energy Information  

Open Energy Info (EERE)

Consumer Tips for Lowering Your Utility Bill Consumer Tips for Lowering Your Utility Bill Jump to: navigation, search Whether you are a residential or commercial customer, your monthly utility bill contains a wide range of data such as how much energy you use, what your current rate is, and detailed fees. Depending on how much information your utility provider offers, you can refer to it along with these tips to reduce your energy use and save money. For in-depth tips on saving energy and money at home, visit EnergySavers.gov. If you have 13 months of historical data on your bill: See if you're using more energy now than you did during the same month last year. Are you using more energy? Look for ways to use less electricity such as purchasing energy efficient appliances and lighting and using a programmable thermostat.

Note: This page contains sample records for the topic "kw billing demand" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Reduce Your Heating Bills with Better Insulation | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Reduce Your Heating Bills with Better Insulation Reduce Your Heating Bills with Better Insulation Reduce Your Heating Bills with Better Insulation October 3, 2008 - 11:09am Addthis John Lippert If you pay your own energy bills, you don't need to be reminded that energy prices are escalating. Energy price projections for this coming winter are not encouraging. According to the Energy Information Administration, residential natural gas prices during the upcoming heating season (October though March) are projected to average $14.93 per Mcf, an increase of about 17% compared to last year's heating season. Residential heating oil prices are projected to average $4.13 per gallon this winter, an increase of about 25%. What if you live in an all-electric house? Many utilities are continuing to pursue retail electricity rate increases in response to power generation

122

Clean Energy On-Bill Financing (Connecticut) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Clean Energy On-Bill Financing (Connecticut) Clean Energy On-Bill Financing (Connecticut) Clean Energy On-Bill Financing (Connecticut) < Back Eligibility Residential Savings Category Biofuels Alternative Fuel Vehicles Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Hydrogen & Fuel Cells Water Solar Home Weatherization Heating & Cooling Water Heating Wind Program Info Start Date 4/1/2014 State Connecticut Program Type State Loan Program Provider Clean Energy Finance and Investment Authority By April 1, 2014, the Energy Conservation Management Board and the Clean Energy Finance and Investment Authority (CEFIA) must consult with electric distribution companies and gas companies to develop a residential clean energy on-bill repayment program. The program will be financed by

123

Energy Efficiency & On-Bill Financing for Small Businesses  

NLE Websites -- All DOE Office Websites (Extended Search)

Efficiency Efficiency & On-Bill Financing For Small Businesses Presentation for: Webinar DOE 05/11/2011 5/12/2011 Connecticut Energy Efficiency Fund (CEEF) Connecticut's Energy Efficiency Programs are funded by a Charge on Customer's electric bills. The Programs are designed to help customers manage their energy usage and cost. Objective PROVIDE > COST-EFFECTIVE, turn-key CONSERVATION and LOAD MANAGEMENT SERVICES to SMALL C&I CUSTOMERS. What qualifies as a SMALL BUSINESS? A "Mom & Pop" store with a $150 monthly electric bill up to a mid size manufacturing company with a $20,000 monthly electric bill. Examples: Retail, convenience stores, houses of worship, professional offices, non-profits, gas stations, restaurants, common areas of apartment buildings,

124

Reduce Your Heating Bills with Better Insulation | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Reduce Your Heating Bills with Better Insulation Reduce Your Heating Bills with Better Insulation Reduce Your Heating Bills with Better Insulation October 3, 2008 - 11:09am Addthis John Lippert If you pay your own energy bills, you don't need to be reminded that energy prices are escalating. Energy price projections for this coming winter are not encouraging. According to the Energy Information Administration, residential natural gas prices during the upcoming heating season (October though March) are projected to average $14.93 per Mcf, an increase of about 17% compared to last year's heating season. Residential heating oil prices are projected to average $4.13 per gallon this winter, an increase of about 25%. What if you live in an all-electric house? Many utilities are continuing to pursue retail electricity rate increases in response to power generation

125

Take a Vacation from Your Energy Bill | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Take a Vacation from Your Energy Bill Take a Vacation from Your Energy Bill Take a Vacation from Your Energy Bill November 16, 2011 - 2:48pm Addthis Kristin Swineford Communication Specialist, Weatherization and Intergovernmental Programs We are always talking about preparing our homes for energy efficiency and taking the right steps to decrease our carbon footprints as homeowners and renters. I realized today that it's already the middle of November, meaning it's time to begin preparing for holiday vacations. I can't think of a better time than now to revisit the ways we can save money on our energy bills this holiday season. In my household, there will be about seven consecutive days in December when no one will be home, not even the dog. Aside from the usual preparations, such as clothing and gift shopping,

126

Upping Efficiency Standards, Lowering Utility Bills | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Upping Efficiency Standards, Lowering Utility Bills Upping Efficiency Standards, Lowering Utility Bills Upping Efficiency Standards, Lowering Utility Bills September 2, 2010 - 4:17pm Addthis Niketa Kumar Niketa Kumar Public Affairs Specialist, Office of Public Affairs What does this mean for me? Using energy-efficient appliances is one of the easiest and most important ways consumers have to save money. Purchasing energy-efficient appliances is one of the easiest and most important ways consumers have to save money, reduce their electricity consumption and help cut down on carbon pollution. We use appliances every day - to cook our food, cool our homes, heat our water and clean our clothes. In fact, for a typical U.S. family, heating and cooling and water heating account for about 50 percent of utility bills. Home appliances and

127

DOE - Office of Legacy Management -- Billings Hospital - Small Animal  

Office of Legacy Management (LM)

Billings Hospital - Small Animal Billings Hospital - Small Animal Facility - University of Chicago - IL 01 FUSRAP Considered Sites Site: Billings Hospital, Small Animal Facility, University of Chicago (IL 01) Eliminated from consideration under FUSRAP due to limited scope of activities and 15 day half-life of P-32 Designated Name: Not Designated Alternate Name: Small Animal Facility, U. of Chicago IL.01-1 Location: University of Chicago , Chicago , Illinois IL.01-1 Evaluation Year: 1979 IL.01-1 Site Operations: Nature of operations is not clear. Portions of Billings Hospital were reported to have been used as an animal research facility. IL.01-1 Site Disposition: Eliminated IL.01-1 Radioactive Materials Handled: Yes Primary Radioactive Materials Handled: Phosphorus - 32 IL.01-1

128

DOE Names Bill Drummond As New Bonneville Power Administration  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Names Bill Drummond As New Bonneville Power Administration Names Bill Drummond As New Bonneville Power Administration Administrator DOE Names Bill Drummond As New Bonneville Power Administration Administrator January 16, 2013 - 7:00pm Addthis News Media Contact (202) 586-4940 WASHINGTON - The Energy Department has chosen Bill Drummond to be the new Administrator for the Bonneville Power Administration (BPA), one of the four Power Marketing Administrations (PMAs) the Department oversees. As BPA's Administrator, Drummond will be responsible for managing the non-profit federal agency, which markets carbon-free power from Columbia River hydroelectic dams and operates the surrounding power grid, distributing wind, nuclear and other energy to the Pacific Northwest and beyond. Drummond's leadership of BPA is part of a larger strategy for

129

Summary of Major Energy Bill Provisions Affecting Federal Energy Managers  

NLE Websites -- All DOE Office Websites (Extended Search)

of Major Energy Bill Provisions Affecting Federal Energy Managers of Major Energy Bill Provisions Affecting Federal Energy Managers Section Lead Agency Provisions 102. Energy management goals DOE * Annual energy reduction goal of 2% from FY 2006 - FY 2015 * Reporting baseline changed from 1985 to 2003 * In 180 days, DOE issues guidelines * Retention of energy and water savings by agencies * DOE reports annually on progress to the President and Congress

130

Summary of Major Energy Bill Provisions Affecting Federal Energy Managers  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

of Major Energy Bill Provisions Affecting Federal Energy Managers of Major Energy Bill Provisions Affecting Federal Energy Managers Section Lead Agency Provisions 102. Energy management goals DOE * Annual energy reduction goal of 2% from FY 2006 - FY 2015 * Reporting baseline changed from 1985 to 2003 * In 180 days, DOE issues guidelines * Retention of energy and water savings by agencies * DOE reports annually on progress to the President and Congress

131

An Introduction to Texas Senate Bill 5  

E-Print Network (OSTI)

Four areas in Texas have been designated by the U.S. Environmental Protection Agency (EPA) as non-attainment areas because ozone levels exceed the National Ambient Air Quality Standards (NAAQS) maximum allowable limits: Beaumont-Port Arthur, El Paso, Dallas-Ft. Worth, and Houston-Galveston-Brazoria. The El Paso area also violates the NAAQS maximum allowable limits for carbon monoxide and respirable particulate matter. These areas face severe sanctions, such as loss of access to federal transportation funds, if attainment is not reached by 2007. Four additional areas in the state are also approaching national ozone limits, including: Austin, Corpus Christi, San Antonio, and the Longview-Tyler-Marshall area. Ozone is formed when oxides of nitrogen (NOx), volatile organic compounds (VOCs), and oxygen (O2) combine in the presence of strong sunlight. In response to this effort the Texas Natural Resource Conservation Commission (TNRCC) developed a strategy with the EPA that reduced VOCs from large regulated, stationary point sources by over 50 percent during the 1990 to 1996 period. Although this first strategy was very successful, levels of ozone failed to meet the national standards, and a second strategy had to be developed to achieve compliance with the ozone standard. In 2001, the Texas State Senate passed Senate Bill 5 (SB 5) to further reduce ozone levels by encouraging the reduction of emissions of NOx by sources that are currently not regulated by the TNRCC, including area sources (e.g., residential emissions), on-road mobile sources (e.g., all types of motor vehicles), and non-road mobile sources (e.g., aircraft, locomotives, etc.). This paper outlines the legislation, and responsibilities of the different government entities and the important role that private industry is being encouraged to play.

Haberl, J. S.; Culp, C.; Yazdani, B.; Fitzpatrick, T.; Turner, W. D.

2002-01-01T23:59:59.000Z

132

Mass Market Demand Response  

NLE Websites -- All DOE Office Websites (Extended Search)

Mass Market Demand Response Mass Market Demand Response Speaker(s): Karen Herter Date: July 24, 2002 - 12:00pm Location: Bldg. 90 Demand response programs are often quickly and poorly crafted in reaction to an energy crisis and disappear once the crisis subsides, ensuring that the electricity system will be unprepared when the next crisis hits. In this paper, we propose to eliminate the event-driven nature of demand response programs by considering demand responsiveness a component of the utility obligation to serve. As such, demand response can be required as a condition of service, and the offering of demand response rates becomes a requirement of utilities as an element of customer service. Using this foundation, we explore the costs and benefits of a smart thermostat-based demand response system capable of two types of programs: (1) a mandatory,

133

Demand Impacted by Weather  

U.S. Energy Information Administration (EIA)

When you look at demand, it’s also interesting to note the weather. The weather has a big impact on the demand of heating fuels, if it’s cold, consumers will use ...

134

Demand Trading Toolkit  

Science Conference Proceedings (OSTI)

Download report 1006017 for FREE. The global movement toward competitive markets is paving the way for a variety of market mechanisms that promise to increase market efficiency and expand customer choice options. Demand trading offers customers, energy service providers, and other participants in power markets the opportunity to buy and sell demand-response resources, just as they now buy and sell blocks of power. EPRI's Demand Trading Toolkit (DTT) describes the principles and practice of demand trading...

2001-12-10T23:59:59.000Z

135

10 kW SOFC POWER SYSTEM COMMERCIALIZATION  

SciTech Connect

The program is organized into three developmental periods. In Phase 1 the team will develop and demonstrate a proof-of-concept prototype design and develop a manufacturing plan to substantiate potential producibility at a target cost level of $800/kW factory manufacturing cost. Phase 2 will further develop the design and reduce the manufacturing cost to a level of $600 kW. Depending on an assessment of the maturity of the technology at the end of Phase 1, Phase 2 may be structured and supplemented to provide a limited production capability. Finally, in Phase 3, a full Value Package Introduction (VPI) Program will be integrated into the SECA program to develop a mass-producible design at a factory cost of $400/kW with full cross-functional support for unrestricted commercial sales. The path to market for new technology products in the Cummins system involves two processes. The first is called Product Preceding Technology, or PPT. The PPT process provides a methodology for exploring potentially attractive technologies and developing them to the point that they can be reliably scheduled into a new product development program with a manageable risk to the product introduction schedule or product quality. Once a technology has passed the PPT gate, it is available to be incorporated into a Value Package Introduction (VPI) Program. VPI is the process that coordinates the cross-functional development of a fully supported product. The VPI Program is designed to synchronize efforts in engineering, supply, manufacturing, marketing, finance, and product support areas in such a way that the product, when introduced to the market, represents the maximum value to the customer.

Dan Norrick; Brad Palmer; Charles Vesely; Eric Barringer; Cris DeBellis; Rich Goettler; Kurt Kneidel; Milind Kantak; Steve Kung; Tom Morris; Greg Rush

2004-02-01T23:59:59.000Z

136

10 kW SOFC POWER SYSTEM COMMERCIALIZATION  

SciTech Connect

The program is organized into three developmental periods. In Phase 1 the team will develop and demonstrate a proof-of-concept prototype design and develop a manufacturing plan to substantiate potential producibility at a target cost level of $800/kW factory manufacturing cost. Phase 2 will further develop the design and reduce the manufacturing cost to a level of $600 kW. Depending on an assessment of the maturity of the technology at the end of Phase 1, Phase 2 may be structured and supplemented to provide a limited production capability. Finally, in Phase 3, a full Value Package Introduction (VPI) Program will be integrated into the SECA program to develop a mass-producible design at a factory cost of $400/kW with full cross-functional support for unrestricted commercial sales. The path to market for new technology products in the Cummins system involves two processes. The first is called Product Preceding Technology, or PPT. The PPT process provides a methodology for exploring potentially attractive technologies and developing them to the point that they can be reliably scheduled into a new product development program with a manageable risk to the product introduction schedule or product quality. Once a technology has passed the PPT gate, it is available to be incorporated into a Value Package Introduction (VPI) Program. VPI is the process that coordinates the cross-functional development of a fully supported product. The VPI Program is designed to synchronize efforts in engineering, supply, manufacturing, marketing, finance, and product support areas in such a way that the product, when introduced to the market, represents the maximum value to the customer.

Dan Norrick; Brad Palmer; Todd Romine; Charles Vesely; Eric Barringer; Cris DeBellis; Rich Goettler; Kurt Kneidel; Milind Kantak; Steve Kung; Greg Rush

2003-08-01T23:59:59.000Z

137

Comparison groups on bills: Automated, personalized energy information  

SciTech Connect

A program called ``Innovative Billing?? has been developed to provide individualized energy information for a mass audience?the entireresidential customer base of an electric or gas utility. Customers receive a graph on the bill that compares that customer?s consumption with othersimilar customers for the same month. The program aims to stimulate customers to make ef?ciency improvements. To group as many as severalmillion customers into small ``comparison groups??, an automated method must be developed drawing solely from the data available to the utility.This paper develops and applies methods to compare the quality of resulting comparison groups.A data base of 114,000 customers from a utility billing system was used to evaluate Innovative Billing comparison groups, comparing fouralternative criteria: house characteristics (?oor area, housing type, and heating fuel); street; meter read route; billing cycle. Also, customers wereinterviewed to see what forms of comparison graphs made most sense and led to fewest errors of interpretation. We ?nd that good qualitycomparison groups result from using street name, meter book, or multiple house characteristics. Other criteria we tested, such as entire cycle, entiremeter book, or single house characteristics such as ?oor area, resulted in poor quality comparison groups. This analysis provides a basis forchoosing comparison groups based on extensive user testing and statistical analysis. The result is a practical set of guidelines that can be used toimplement realistic, inexpensive innovative billing for the entire customer base of an electric or gas utility.

Iyer, Maithili; Kempton, Willett; Payne, Christopher

2006-07-01T23:59:59.000Z

138

Browse wiki | Open Energy Information  

Open Energy Info (EERE)

0 + OpenEIUtilityRateDemandRateUnit kW + OpenEIUtilityRateDescription If the energy usage in the monthly billing ... If the energy usage in the monthly billing period...

139

205 kW Photovoltaic (PV) System Installed on the U.S. Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

205 kW Photovoltaic (PV) System Installed on the U.S. Department of Energy's Forrestal Building 205 kW Photovoltaic (PV) System Installed on the U.S. Department of Energy's...

140

NREL: Buildings Research - Utility Bill Calibration Test Cases  

NLE Websites -- All DOE Office Websites (Extended Search)

Utility Bill Calibration Test Cases Utility Bill Calibration Test Cases The diagram below illustrates the utility bill calibration test cases in BESTEST-EX. In these cases, participants are given input ranges and synthetic utility bills. Software tools calibrate key model inputs using the utility bills and then predict energy savings for the different retrofit cases. Participant energy savings predictions using calibrated models are compared to NREL predictions using state-of-the-art building energy simulation programs. For self-testing, participants should not view reference results until after tested software results have been generated. This diagram provides an overview of the BESTEST-EX utility bill calibration case process. On the left side of the diagram is a box labeled "BESTEST-EX Document" with a list that contains two bulleted items. The first bullet reads "Defines a representative existing home and several retrofit measures." The second bullet reads "Provides input ranges for key model inputs." Underneath this list is an image of a house and to the right of the house is a listing of the measures: R-wall=4.5-6.2; ELA=137-216 in2 ; Tsat=60-75°F, etc. Underneath this grouping is another bullet that reads "Presents utility bills that were generated by: A) randomly selecting key model inputs within ranges (values remain hidden); B) running test cases with selected inputs in EnergyPlus, DOE2.1E, and SUNREL." Below this bullet is a bar graph showing energy savings on the y axis and retrofit measure on the x axis. Inside the graph area is text reading "Reference results remains hidden for utility bill calibration cases." An arrow labeled "Results" points horizontally to the right to the results box. From the top half of this box are two arrows that are labeled "Input Ranges" and "Utility Bills" and points horizontally to the right to another smaller box that is labeled "Audit Software Provider." Underneath this heading are three bullets: one reads "Creates model of existing home knowing input ranges from test," the next one reads "Calibrates model inputs using utility bills," and the third one reads "Predicts retrofit energy savings. Underneath these bullets is an image of a house; to the right of this is a bar graph showing energy savings on the y axis and retrofit measure on the x axis. From this box an arrow labeled "Results" points directly below

Note: This page contains sample records for the topic "kw billing demand" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Rates and technologies for mass-market demand response  

NLE Websites -- All DOE Office Websites (Extended Search)

Rates and technologies for mass-market demand response Rates and technologies for mass-market demand response Title Rates and technologies for mass-market demand response Publication Type Conference Paper LBNL Report Number LBNL-50626 Year of Publication 2002 Authors Herter, Karen, Roger Levy, John Wilson, and Arthur H. Rosenfeld Conference Name 2002 ACEEE Summer Study on Energy Efficiency in Buildings Conference Location Pacific Grove, CA Keywords demand response, demand response and distributed energy resources center, demand response research center, rate programs & tariffs Abstract Demand response programs are often quickly and poorly crafted in reaction to an energy crisis and disappear once the crisis subsides, ensuring that the electricity system will be unprepared when the next crisis hits. In this paper, we propose to eliminate the event-driven nature of demand response programs by considering demand responsiveness a component of the utility obligation to serve. As such, demand response can be required as a condition of service, and the offering of demand response rates becomes a requirement of utilities as an element of customer service. Using this foundation, we explore the costs and benefits of a smart thermostat-based demand response system capable of two types of programs: (1) a mandatory, system-operator controlled, contingency program, and (2) a voluntary, customer controlled, bill management program with rate-based incentives. Any demand response program based on this system could consist of either or both of these components. Ideally, these programs would be bundled, providing automatic load management through customer-programmed price response, plus up to 10 GW of emergency load shedding capability in California. Finally, we discuss options for and barriers to implementation of such a program in California.

142

Demand Response and Open Automated Demand Response Opportunities...  

NLE Websites -- All DOE Office Websites (Extended Search)

Response and Open Automated Demand Response Opportunities for Data Centers Title Demand Response and Open Automated Demand Response Opportunities for Data Centers Publication Type...

143

500-kW DCHX pilot-plant evaluation testing  

DOE Green Energy (OSTI)

Field tests with the 500 kW Direct Contact Pilot Plant were conducted utilizing brine from well Mesa 6-2. The tests were intended to develop comprehensive performance data, design criteria, and economic factors for the direct contact power plant. The tests were conducted in two phases. The first test phase was to determine specific component performance of the DCHX, turbine, condensers and pumps, and to evaluate chemical mass balances of non-condensible gases in the IC/sub 4/ loop and IC/sub 4/ in the brine stream. The second test phase was to provide a longer term run at nearly fixed operating conditions in order to evaluate plant performance and identify operating cost data for the pilot plant. During these tests the total accumulated run time on major system components exceeded 1180 hours with 777 hours on the turbine prime mover. Direct contact heat exchanger performance exceeded the design prediction.

Hlinak, A.; Lee, T.; Loback, J.; Nichols, K.; Olander, R.; Oshmyansky, S.; Roberts, G.; Werner, D.

1981-10-01T23:59:59.000Z

144

Demand Dispatch-Intelligent  

NLE Websites -- All DOE Office Websites (Extended Search)

and energy efficiency throughout the value chain resulting in the most economical price for electricity. Having adequate quantities and capacities of demand resources is a...

145

Demand Response Valuation Frameworks Paper  

E-Print Network (OSTI)

xxxv Option Value of Electricity Demand Response, Osmanelasticity in aggregate electricity demand. With these newii) reduction in electricity demand during peak periods (

Heffner, Grayson

2010-01-01T23:59:59.000Z

146

U.S. Propane Demand  

U.S. Energy Information Administration (EIA)

Demand is higher in 1999 due to higher petrochemical demand and a strong economy. We are also seeing strong demand in the first quarter of 2000; however, ...

147

Automated Demand Response and Commissioning  

E-Print Network (OSTI)

Fully-Automated Demand Response Test in Large Facilities14in DR systems. Demand Response using HVAC in Commercialof Fully Automated Demand Response in Large Facilities”

Piette, Mary Ann; Watson, David S.; Motegi, Naoya; Bourassa, Norman

2005-01-01T23:59:59.000Z

148

Demand Response Spinning Reserve Demonstration  

E-Print Network (OSTI)

F) Enhanced ACP Date RAA ACP Demand Response – SpinningReserve Demonstration Demand Response – Spinning Reservesupply spinning reserve. Demand Response – Spinning Reserve

2007-01-01T23:59:59.000Z

149

Forsyth County Slashes Energy Bills with Upgrades | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Forsyth County Slashes Energy Bills with Upgrades Forsyth County Slashes Energy Bills with Upgrades Forsyth County Slashes Energy Bills with Upgrades September 30, 2010 - 12:04pm Addthis A new energy management system in Forsyth County’s 52,057 square foot courthouse is expected to save about $9,000 annually. | Photo courtesy of Forsyth County A new energy management system in Forsyth County's 52,057 square foot courthouse is expected to save about $9,000 annually. | Photo courtesy of Forsyth County Maya Payne Smart Former Writer for Energy Empowers, EERE What are the key facts? Four large projects funded through Recovery Act grant Energy efficient retrofits to save county about $72,000 annually Forsyth County, Georgia has been among the nation's fastest growing counties for the past ten years. Given the growth, officials are working

150

Secretary Bodman Promotes Energy Bill to Western Governors | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Promotes Energy Bill to Western Governors Promotes Energy Bill to Western Governors Secretary Bodman Promotes Energy Bill to Western Governors March 1, 2005 - 10:37am Addthis WASHINGTON, DC - U.S. Secretary of Energy Samuel W. Bodman in a speech before the Western Governors Association today expressed the need for Congress to pass comprehensive energy legislation and highlighted the benefits of the proposal for the western United States. Secretary Bodman also discussed a number of important energy initiatives including: nuclear defense; scientific research; oil and gas exploration in Alaska; hydropower; the strengthening of our power grid; further development of renewable energy; hydrogen powered fuel-cell vehicles; and clean-coal power generation. "The energy challenges facing our country today are greater than they have

151

Fort Collins Utilities - Residential On-Bill Financing Program Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Fort Collins Utilities - Residential On-Bill Financing Program Fort Collins Utilities - Residential On-Bill Financing Program Program (Colorado) Fort Collins Utilities - Residential On-Bill Financing Program Program (Colorado) < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Appliances & Electronics Sealing Your Home Design & Remodeling Windows, Doors, & Skylights Ventilation Construction Commercial Heating & Cooling Heating & Cooling Heating Heat Pumps Water Heating Solar Maximum Rebate $15,000 Program Info State Colorado Program Type Utility Loan Program Rebate Amount $1,000 - $15,000 Fort Collins offers its residential customers low-interest loans that may be used to finance a variety of projects including adding insulation, replacing a furnace, upgrading water and space heating systems, and

152

Baltimore Vet Cuts Energy Bills With Solar | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Baltimore Vet Cuts Energy Bills With Solar Baltimore Vet Cuts Energy Bills With Solar Baltimore Vet Cuts Energy Bills With Solar October 28, 2010 - 5:09pm Addthis Baltimore resident Paul Bennett installed 14 solar panels such as these on his historic row home with the help of a state solar grant and federal tax credit through the Recovery Act. | Energy Department Photo | Baltimore resident Paul Bennett installed 14 solar panels such as these on his historic row home with the help of a state solar grant and federal tax credit through the Recovery Act. | Energy Department Photo | Stephen Graff Former Writer & editor for Energy Empowers, EERE On a 'green' mission last spring, a 62 year-old retiree living on a modest income in Baltimore found himself at the Solar and Wind Expo at the Timonium Fairgrounds in Maryland.

153

Forsyth County Slashes Energy Bills with Upgrades | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Forsyth County Slashes Energy Bills with Upgrades Forsyth County Slashes Energy Bills with Upgrades Forsyth County Slashes Energy Bills with Upgrades September 30, 2010 - 12:04pm Addthis A new energy management system in Forsyth County’s 52,057 square foot courthouse is expected to save about $9,000 annually. | Photo courtesy of Forsyth County A new energy management system in Forsyth County's 52,057 square foot courthouse is expected to save about $9,000 annually. | Photo courtesy of Forsyth County Maya Payne Smart Former Writer for Energy Empowers, EERE What are the key facts? Four large projects funded through Recovery Act grant Energy efficient retrofits to save county about $72,000 annually Forsyth County, Georgia has been among the nation's fastest growing counties for the past ten years. Given the growth, officials are working

154

Transparent Prices for Municipal Water: Impact of Pricing and Billing  

NLE Websites -- All DOE Office Websites (Extended Search)

Transparent Prices for Municipal Water: Impact of Pricing and Billing Transparent Prices for Municipal Water: Impact of Pricing and Billing Practices on Residential Water Use Speaker(s): Sylvestre Gaudin Date: November 29, 2004 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: John Busch Jr. Economic Research shows overwhelmingly that residential consumers do not pay much attention to price changes when they make decisions about water use. This weak price sensitivity is often attributed to the intrinsic nature of water as a necessity. However, a large part of water use is the result of choices that could easily be altered without affecting basic welfare. Economic theory points to at least two other reasons why consumers would not be responsive to price changes for water use: the fact that water bills constitute a small portion of their budgets, and the fact that price

155

Home Energy Saver: Comparing Your Results to Your Utility Bill  

NLE Websites -- All DOE Office Websites (Extended Search)

Comparing The Results to The Home's Utility Bill Comparing The Results to The Home's Utility Bill Energy use varies widely, even among seemingly identical homes! This is because of differences in house design, appliances, lifestyles, and comfort requirements. If your Home Energy Saver results differ from your actual energy bills, be sure to first check that all your input values agree with how your home is actually designed and operated. If the total cost differs but energy use is the same, keep in mind that we use a single price for energy, while many utilities use complicated "tariff structures", where the price varies by the time of year and/or day, your level of consumption, or other factors. Any remaining differences are probably due to one or more of the factors below. After reviewing these factors, you may want to modify

156

The Renewable Energy Guy: Q&A with TV's Bill Nye | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

The Renewable Energy Guy: Q&A with TV's Bill Nye The Renewable Energy Guy: Q&A with TV's Bill Nye The Renewable Energy Guy: Q&A with TV's Bill Nye June 10, 2010 - 11:42am Addthis Bill Nye currently hosts three television shows about science. | Photo courtesy of Bill Nye Bill Nye currently hosts three television shows about science. | Photo courtesy of Bill Nye Lindsay Gsell For years, Bill Nye entertained children on the educational television series "Bill Nye the Science Guy." Using wacky demonstrations, funny music videos and easy to digest lessons, Nye encouraged children to enjoy and appreciate science. The quirky Nye-a scientist, engineer, comedian, author, and inventor-now works to spread the message of renewable energy, and regularly takes on projects to "green" his own Californian home.

157

The Renewable Energy Guy: Q&A with TV's Bill Nye | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

The Renewable Energy Guy: Q&A with TV's Bill Nye The Renewable Energy Guy: Q&A with TV's Bill Nye The Renewable Energy Guy: Q&A with TV's Bill Nye June 10, 2010 - 11:42am Addthis Bill Nye currently hosts three television shows about science. | Photo courtesy of Bill Nye Bill Nye currently hosts three television shows about science. | Photo courtesy of Bill Nye Lindsay Gsell For years, Bill Nye entertained children on the educational television series "Bill Nye the Science Guy." Using wacky demonstrations, funny music videos and easy to digest lessons, Nye encouraged children to enjoy and appreciate science. The quirky Nye-a scientist, engineer, comedian, author, and inventor-now works to spread the message of renewable energy, and regularly takes on projects to "green" his own Californian home.

158

CONSULTANT REPORT DEMAND FORECAST EXPERT  

E-Print Network (OSTI)

CONSULTANT REPORT DEMAND FORECAST EXPERT PANEL INITIAL forecast, end-use demand modeling, econometric modeling, hybrid demand modeling, energyMahon, Carl Linvill 2012. Demand Forecast Expert Panel Initial Assessment. California Energy

159

Automated Demand Response and Commissioning  

E-Print Network (OSTI)

internal conditions. Maximum Demand Saving Intensity [W/ft2]automated electric demand sheds. The maximum electric shed

Piette, Mary Ann; Watson, David S.; Motegi, Naoya; Bourassa, Norman

2005-01-01T23:59:59.000Z

160

10 kW SOFC Power System Commercialization  

DOE Green Energy (OSTI)

Cummins Power Generation (CPG) as the prime contractor and SOFCo-EFS Holdings LLC (SOFCo), as their subcontractor, teamed under the Solid-state Energy Conversion Alliance (SECA) program to develop 3-10kW solid oxide fuel cell systems for use in recreational vehicles, commercial work trucks and stand-by telecommunications applications. The program goal is demonstration of power systems that meet commercial performance requirements and can be produced in volume at a cost of $400/kW. This report summarizes the team's activities during the seventh six-month period (July-December 2005) of the four-year Phase I effort. While there has been significant progress in the development of the SOFC subsystems that can support meeting the program Phase 1 goals, the SOFCo ceramic stack technology has progressed significantly slower than plan and CPG consider it unlikely that the systemic problems encountered will be overcome in the near term. SOFCo has struggled with a series of problems associated with inconsistent manufacturing, inadequate cell performance, and the achievement of consistent, durable, low resistance inter-cell connections with reduced or no precious materials. A myriad of factors have contributed to these problems, but the fact remains that progress has not kept pace with the SECA program. A contributing factor in SOFCo's technical difficulties is attributed to their significantly below plan industry cost share spending over the last four years. This has resulted in a much smaller SOFC stack development program, has contributed to SOFCo not being able to aggressively resolve core issues, and clouds their ability to continue into a commercialization phase. In view of this situation, CPG has conducted an independent assessment of the state-of-the-art in planar SOFC's stacks and have concluded that alternative technology exists offering the specific performance, durability, and low cost needed to meet the SECA objectives. We have further concluded that there is insufficient evidence to reliably predict that SOFCo will be able to achieve the SECA performance and cost goals on a schedule consistent with SECA or CPG commercialization goals. CPG believes SOFCo have made a good faith effort consistent with the available resources, but have repeatedly fallen short of achieving the programs scheduled targets. CPG has therefore initiated a process of application for extension of Phase 1 of our SECA program with the intent of transitioning to an alternative stack supplier with more mature SOFC technology, and demonstrating a system meeting the SECA Phase 1 goals by the end of calendar 2006. We have identified an alternative supplier and will be reporting the progress on transition and program planning in monthly technical reports, reviews, and in the next semiannual report.

Dan Norrick; Brad Palmer; Charles Vesely; Eric Barringer; John Budge; Cris DeBellis; Rich Goettler; Milind Kantak; Steve Kung; Zhien Liu; Tom Morris; Keith Rackers; Gary Roman; Greg Rush; Liang Xue

2006-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "kw billing demand" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Rates and technologies for mass-market demand response  

SciTech Connect

Demand response programs are often quickly and poorly crafted in reaction to an energy crisis and disappear once the crisis subsides, ensuring that the electricity system will be unprepared when the next crisis hits. In this paper, we propose to eliminate the event-driven nature of demand response programs by considering demand responsiveness a component of the utility obligation to serve. As such, demand response can be required as a condition of service, and the offering of demand response rates becomes a requirement of utilities as an element of customer service. Using this foundation, we explore the costs and benefits of a smart thermostat-based demand response system capable of two types of programs: (1) a mandatory, system-operator controlled, contingency program, and (2) a voluntary, customer controlled, bill management program with rate-based incentives. Any demand response program based on this system could consist of either or both of these components. Ideally, these programs would be bundled, providing automatic load management through customer-programmed price response, plus up to 10 GW of emergency load shedding capability in California. Finally, we discuss options for and barriers to implementation of such a program in California.

Herter, Karen; Levy, Roger; Wilson, John; Rosenfeld, Arthur

2002-07-21T23:59:59.000Z

162

www.ucei.org Customer Risk from Real-Time Retail Electricity Pricing: Bill Volatility and Hedgability  

E-Print Network (OSTI)

Abstract: One of the most critical concerns that customers have voiced in the debate over real-time retail electricity pricing is that they would be exposed to risk from fluctuations in their electricity cost. The concern seems to be that a customer could find itself consuming a large quantity of power on the day that prices skyrocket and thus receive a monthly bill far larger than it had budgeted for. I analyze the magnitude of this risk, using demand data from 1142 large industrial customers, and then ask how much of this risk can be eliminated through various straightforward financial instruments. I find that very simple hedging strategies can eliminate more than 80 % of the bill volatility that would otherwise occur. Far from being complex, mystifying financial instruments that only a Wall Street analyst could love, these are simple forward power purchase contracts, and are already offered to retail customers by a number of fully-regulated utilities that operate real-time pricing programs. I then show that a slightly more sophisticated application of these forward power purchases can significantly enhance their effect on reducing bill volatility. 1

Severin Borenstein; Severin Borenstein

2006-01-01T23:59:59.000Z

163

Commercial Demand Module  

Gasoline and Diesel Fuel Update (EIA)

2 2 Commercial Demand Module The NEMS Commercial Sector Demand Module generates projections of commercial sector energy demand through 2035. The definition of the commercial sector is consistent with EIA's State Energy Data System (SEDS). That is, the commercial sector includes business establishments that are not engaged in transportation or in manufacturing or other types of industrial activity (e.g., agriculture, mining or construction). The bulk of commercial sector energy is consumed within buildings; however, street lights, pumps, bridges, and public services are also included if the establishment operating them is considered commercial. Since most of commercial energy consumption occurs in buildings, the commercial module relies on the data from the EIA

164

Molten carbonate fuel cell technology improvement. [25 kW  

DOE Green Energy (OSTI)

This report summarizes the work performed under Department of Energy Contract AC21-87MC23270 during the period March 1, through May 30, 1990. The overall objective of this program is to define a competitive CG/MCFC power plant and the associated technology development requirements and to develop an improved cell configuration for molten carbonate fuel cells which has improved performance, has reduced cell creep and electrolyte management consistent with 40,000 hour projected life, reduces existing cell cost, and is adaptable to a range of power plant applications. The 8-ft{sup 2} 20-cell, 25-kW stack assembly and installation in the test facility were completed. Testing of the stack was started and 896 hours of test time were reached. Manifold seal development focused on a seal to reduce electrolyte transport and test rigs were initiated for shunt current and seal leakage evaluation. Development on sheet metal parts was initiated with focus on improved aluminization for separator plate corrosion protection and nickel clad stainless steel for the anode current collector. Development of porous parts was initiated with focus on an alternative binder for the electrodes. Design of a laboratory scale continuous debinding oven was completed. Development of an improved material blend for the matrix was also initiated. 19 figs., 2 tabs.

Not Available

1990-09-01T23:59:59.000Z

165

Characterization of Settler Tank and KW Container Sludge Simulants  

SciTech Connect

The Sludge Treatment Project (STP), managed by CH2M Hill Plateau Remediation Company (CHPRC) has specified base formulations for non-radioactive sludge simulants for use in the development and testing of equipment for sludge sampling, retrieval, transport, and processing. In general, the simulant formulations are based on the average or design-basis physical and chemical properties obtained by characterizing sludge samples. The simulants include surrogates for uranium metal, uranium oxides (agglomerates and fine particulate), and the predominant chemical phases (iron and aluminum hydroxides, sand). Specific surrogate components were selected to match the nominal particle-size distribution and particle-density data obtained from sludge sample analysis. Under contract to CHPRC, Pacific Northwest National Laboratory (PNNL) has performed physical and rheological characterization of simulants, and the results are reported here. Two base simulant types (dry) were prepared by STP staff at the Maintenance and Storage Facility and received by PNNL on February 12, 2009: Settler Tank Simulant and KW Container Sludge Simulant. The objectives of this simulant characterization effort were to provide baseline characterization data on simulants being used by STP for process development and equipment testing and provide a high-level comparison of the simulant characteristics to the targets used to formulate the simulants.

Burns, Carolyn A.; Luna, Maria; Schmidt, Andrew J.

2009-05-12T23:59:59.000Z

166

Two Years Later: Bill Picciano of DOE's Savannah River Site  

Energy.gov (U.S. Department of Energy (DOE))

We checked back in with Bill Picciano, who we last spoke to in October 2009 after he'd recently been hired at the Savannah River Site (SRS) through the Recovery Act. Now he's permanently employed at the Site as an Associate Engineer/Technical Support Specialist - a job he's proud to have.

167

AMENDED IN SENATE MARCH 27, 2006 SENATE BILL No. 1629  

E-Print Network (OSTI)

Act. The State Contract Act governs contracting between state agencies and private contractors, and other state agencies in overseeing and implementing state contracting procedures and policies. This bill procedures and policies to require authorize a state agency that contracts with a federally funded research

Knowles, David William

168

Mann LED Elevator Ligh ng: ECI Savings Table Cost (billed)  

E-Print Network (OSTI)

Cost (billed) Annual Savings $ Equivalent # Homes Electric 63 12 51 81% 1,300 200 1,000 2 tons/per year car bon equivalent annually. Benefits: The new lamps are much cooler, lower energy usage, and will last up to 5 years versus the old lamps that re quired changing many mes per year

Lipson, Michal

169

Uncertainties in the Value of Bill Savings from Behind-the-Meter, Residential Photovoltaic Systems: The Roles of Electricity Market Conditions, Retail Rate Design, and Net Metering  

E-Print Network (OSTI)

77 CHAPTER 4 ELECTRICITY BILL SAVINGS FROM RESIDENTIALresidential load and electricity bill by TOU period. (in the customer’s electricity bills. The second chapter of

Darghouth, Naim Richard

2013-01-01T23:59:59.000Z

170

Re DSM: Here comes demand-side marketing  

SciTech Connect

Demand-side management (DSM) programs where utilities pay large rebates for energy efficient equipment are being declared dead. The popular view of DSM in the past was to encourage conservation of energy with significant rebates, credits and other incentives offered by electric and also natural gas utilities. After years of increase in utility DSM expenditures, the first decline took place last year of about 6% for the electric industry. Although still spending more than $2 billion in 1994, utilities have continued this year to reduce the number of DSM programs. For some utilities there has been a dramatic abandonment of energy efficiency incentive programs. Where programs remain, utilities are placing increased emphasis on the most cost-effective ones which are usually directed toward commercial and industrial facilities. At the same time utilities have been transforming their programs from demand-side management to demand-side marketing. The objectives have shifted to retaining existing customers, developing new accounts, and increasing profitable sales. Incentives are justified in this new cost-driven competitive environment when they result in decreased rates for all customers. Whereas, in the past, DSM program participants were the primary beneficiaries with reduced bills, in the new marketing environment all customers can benefit from reduced bills.

Barrett, L.B. [Barrett Consulting Associates, Inc., Colorado Springs, CO (United States)

1996-06-01T23:59:59.000Z

171

Open Automated Demand Response for Small Commerical Buildings  

Science Conference Proceedings (OSTI)

This report characterizes small commercial buildings by market segments, systems and end-uses; develops a framework for identifying demand response (DR) enabling technologies and communication means; and reports on the design and development of a low-cost OpenADR enabling technology that delivers demand reductions as a percentage of the total predicted building peak electric demand. The results show that small offices, restaurants and retail buildings are the major contributors making up over one third of the small commercial peak demand. The majority of the small commercial buildings in California are located in southern inland areas and the central valley. Single-zone packaged units with manual and programmable thermostat controls make up the majority of heating ventilation and air conditioning (HVAC) systems for small commercial buildings with less than 200 kW peak electric demand. Fluorescent tubes with magnetic ballast and manual controls dominate this customer group's lighting systems. There are various ways, each with its pros and cons for a particular application, to communicate with these systems and three methods to enable automated DR in small commercial buildings using the Open Automated Demand Response (or OpenADR) communications infrastructure. Development of DR strategies must consider building characteristics, such as weather sensitivity and load variability, as well as system design (i.e. under-sizing, under-lighting, over-sizing, etc). Finally, field tests show that requesting demand reductions as a percentage of the total building predicted peak electric demand is feasible using the OpenADR infrastructure.

Dudley, June Han; Piette, Mary Ann; Koch, Ed; Hennage, Dan

2009-05-01T23:59:59.000Z

172

Industrial Demand Module  

Gasoline and Diesel Fuel Update (EIA)

2 2 Industrial Demand Module The NEMS Industrial Demand Module estimates energy consumption by energy source (fuels and feedstocks) for 15 manufacturing and 6 non-manufacturing industries. The manufacturing industries are further subdivided into the energy- intensive manufacturing industries and non-energy-intensive manufacturing industries (Table 6.1). The manufacturing industries are modeled through the use of a detailed process-flow or end-use accounting procedure, whereas the non- manufacturing industries are modeled with substantially less detail. The petroleum refining industry is not included in the Industrial Demand Module, as it is simulated separately in the Petroleum Market Module of NEMS. The Industrial Demand Module calculates energy consumption for the four Census Regions (see Figure 5) and disaggregates the energy consumption

173

demand | OpenEI  

Open Energy Info (EERE)

demand demand Dataset Summary Description This dataset contains hourly load profile data for 16 commercial building types (based off the DOE commercial reference building models) and residential buildings (based off the Building America House Simulation Protocols). This dataset also includes the Residential Energy Consumption Survey (RECS) for statistical references of building types by location. Source Commercial and Residential Reference Building Models Date Released April 18th, 2013 (9 months ago) Date Updated July 02nd, 2013 (7 months ago) Keywords building building demand building load Commercial data demand Energy Consumption energy data hourly kWh load profiles Residential Data Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Annually

174

Demand Response Database & Demo  

NLE Websites -- All DOE Office Websites (Extended Search)

Demand Response Database & Demo Speaker(s): Mike Graveley William M. Smith Date: June 7, 2005 - 12:00pm Location: Bldg. 90 Seminar HostPoint of Contact: Mary Ann Piette Infotility...

175

Tankless Demand Water Heaters  

Energy.gov (U.S. Department of Energy (DOE))

Demand (tankless or instantaneous) water heaters have heating devices that are activated by the flow of water, so they provide hot water only as needed and without the use of a storage tank. They...

176

Residential Sector Demand Module  

Reports and Publications (EIA)

Model Documentation - Documents the objectives, analytical approach, and development of the National Energy Modeling System (NEMS) Residential Sector Demand Module. The report catalogues and describes the model assumptions, computational methodology, parameter estimation techniques, and FORTRAN source code.

Owen Comstock

2012-12-19T23:59:59.000Z

177

Industrial Demand Module  

Reports and Publications (EIA)

Documents the objectives, analytical approach, and development of the National Energy Modeling System (NEMS) Industrial Demand Module. The report catalogues and describes model assumptions, computational methodology, parameter estimation techniques, and model source code.

Kelly Perl

2013-05-14T23:59:59.000Z

178

Industrial Demand Module  

Reports and Publications (EIA)

Documents the objectives, analytical approach, and development of the National Energy Modeling System (NEMS) Industrial Demand Module. The report catalogues and describes model assumptions, computational methodology, parameter estimation techniques, and model source code.

Kelly Perl

2013-09-30T23:59:59.000Z

179

Residential Sector Demand Module  

Reports and Publications (EIA)

Model Documentation - Documents the objectives, analytical approach, and development of the National Energy Modeling System (NEMS) Residential Sector Demand Module. The report catalogues and describes the model assumptions, computational methodology, parameter estimation techniques, and FORTRAN source code.

Owen Comstock

2013-11-05T23:59:59.000Z

180

Transportation Demand This  

U.S. Energy Information Administration (EIA) Indexed Site

Transportation Demand Transportation Demand This page inTenTionally lefT blank 75 U.S. Energy Information Administration | Assumptions to the Annual Energy Outlook 2013 Transportation Demand Module The NEMS Transportation Demand Module estimates transportation energy consumption across the nine Census Divisions (see Figure 5) and over ten fuel types. Each fuel type is modeled according to fuel-specific and associated technology attributes applicable by transportation mode. Total transportation energy consumption is the sum of energy use in eight transport modes: light-duty vehicles (cars and light trucks), commercial light trucks (8,501-10,000 lbs gross vehicle weight), freight trucks (>10,000 lbs gross vehicle weight), buses, freight and passenger aircraft, freight

Note: This page contains sample records for the topic "kw billing demand" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Automated Demand Response Tests  

Science Conference Proceedings (OSTI)

This report includes assessments and test results of four end-use technologies, representing products in the residential, commercial, and industrial sectors, each configured to automatically receive real-time pricing information and critical peak pricing (CPP) demand response (DR) event notifications. Four different vendors were asked to follow the interface requirements set forth in the Open Automated Demand Response (OpenADR) standard that was introduced to the public in 2008 and currently used in two ...

2008-12-22T23:59:59.000Z

182

Automated Demand Response Tests  

Science Conference Proceedings (OSTI)

This report, which is an update to EPRI Report 1016082, includes assessments and test results of four end-use vendor technologies. These technologies represent products in the residential, commercial, and industrial sectors, each configured to automatically receive real-time pricing information and critical peak pricing (CPP) demand response (DR) event notifications. Four different vendors were asked to follow the interface requirements set forth in the Open Automated Demand Response (OpenADR) Communicat...

2009-03-30T23:59:59.000Z

183

Tapping Solar for Hot Water and Cheaper Bills for Puerto Rico...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tapping Solar for Hot Water and Cheaper Bills for Puerto Rico Tapping Solar for Hot Water and Cheaper Bills for Puerto Rico November 3, 2010 - 10:00am Addthis Stephen Graff Former...

184

15 Ways to Save on Your Water Heating Bill | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

5 Ways to Save on Your Water Heating Bill 15 Ways to Save on Your Water Heating Bill October 26, 2009 - 3:49pm Addthis Allison Casey Senior Communicator, NREL Sometimes it...

185

Gas Mileage of 1984 Vehicles by Bill Dovell Motor Car Company  

NLE Websites -- All DOE Office Websites (Extended Search)

4 Bill Dovell Motor Car Company Vehicles EPA MPG MODEL City Comb Hwy 1984 Bill Dovell Motor Car Company Dovell 230CE 4 cyl, 2.3 L, Automatic 4-spd, Regular Gasoline Compare 1984...

186

Gas Mileage of 1985 Vehicles by Bill Dovell Motor Car Company  

NLE Websites -- All DOE Office Websites (Extended Search)

5 Bill Dovell Motor Car Company Vehicles EPA MPG MODEL City Comb Hwy 1985 Bill Dovell Motor Car Company Dovell 230CE 4 cyl, 2.3 L, Automatic 4-spd, Regular Gasoline Compare 1985...

187

Comparison of Distributed Generation Technology Options, 250-400 kW  

Science Conference Proceedings (OSTI)

The Los Angeles County Sanitation Districts own and operate biogas-fueled generating plants at a number of sites. Included in their portfolio are a 250 kW carbonate fuel cell, a 250 kW microturbine, a 400 kW internal combustion engine, and a cluster of ten (10) 30-kW microturbines. This afforded a unique opportunity to compare the power generation technologies. All of these systems use bio-gas that would otherwise be flared and generate power in parallel with the local utility to offset site electrical p...

2006-03-09T23:59:59.000Z

188

225-kW Dynamometer for Testing Small Wind Turbine Components  

DOE Green Energy (OSTI)

Poster for WindPower 2006 held June 4-7, 2006, in Pittsburgh, PA, describing the 225-kW dynamometer for testing small wind turbine components.

Green, J.

2006-06-01T23:59:59.000Z

189

Test #6.5, natural gas, HRR=400 kW  

Science Conference Proceedings (OSTI)

*. Bookmark and Share. Reduced Scale Enclosure Fire Images (NIST TN1483). Test #6.5, natural gas, HRR=400 kW.

2012-03-20T23:59:59.000Z

190

New NIST Video: Bill Phillips School Talk on the Science of ...  

Science Conference Proceedings (OSTI)

New NIST Video: Bill Phillips School Talk on the Science of Ultracold. From NIST Tech Beat: February 19, 2008. ...

2011-08-29T23:59:59.000Z

191

Taking compliance patterns and quality management system (QMS) framework approach to ensure medical billing compliance  

Science Conference Proceedings (OSTI)

The United States Office of Inspector General (OIG) has issued a number of compliance guidelines including third-party medical billing guidelines for healthcare companies in the United States to reduce errors and fraud in the field of medical billing. ... Keywords: ISO 9001, OIG, common audit framework, medical billing compliance patterns, quality management system (QMS)

Syeda Uzma Gardazi, Arshad Ali Shahid

2013-03-01T23:59:59.000Z

192

Addressing Energy Demand through Demand Response: International Experiences and Practices  

E-Print Network (OSTI)

time. 4 Reducing this peak demand through DR programs meansthat a 5% reduction in peak demand would have resulted insame 5% reduction in the peak demand of the US as a whole.

Shen, Bo

2013-01-01T23:59:59.000Z

193

Demand and Price Volatility: Rational Habits in International Gasoline Demand  

E-Print Network (OSTI)

shift in the short-run price elasticity of gasoline demand.A meta-analysis of the price elasticity of gasoline demand.2007. Consumer demand un- der price uncertainty: Empirical

Scott, K. Rebecca

2011-01-01T23:59:59.000Z

194

California Independent System Operator demand response & proxy demand resources  

Science Conference Proceedings (OSTI)

Demand response programs are designed to allow end use customers to contribute to energy load reduction individually or through a demand response provider. One form of demand response can occur when an end use customer reduces their electrical usage ...

John Goodin

2012-01-01T23:59:59.000Z

195

Commercial Demand Module  

Gasoline and Diesel Fuel Update (EIA)

This page intentionally left blank This page intentionally left blank 39 U.S. Energy Information Administration | Assumptions to the Annual Energy Outlook 2011 Commercial Demand Module The NEMS Commercial Sector Demand Module generates projections of commercial sector energy demand through 2035. The definition of the commercial sector is consistent with EIA's State Energy Data System (SEDS). That is, the commercial sector includes business establishments that are not engaged in transportation or in manufacturing or other types of industrial activity (e.g., agriculture, mining or construction). The bulk of commercial sector energy is consumed within buildings; however, street lights, pumps, bridges, and public services are also included if the establishment operating them is considered commercial.

196

Residential Demand Module  

Gasoline and Diesel Fuel Update (EIA)

2 2 Residential Demand Module The NEMS Residential Demand Module projects future residential sector energy requirements based on projections of the number of households and the stock, efficiency, and intensity of energy-consuming equipment. The Residential Demand Module projections begin with a base year estimate of the housing stock, the types and numbers of energy-consuming appliances servicing the stock, and the "unit energy consumption" (UEC) by appliance (in million Btu per household per year). The projection process adds new housing units to the stock, determines the equipment installed in new units, retires existing housing units, and retires and replaces appliances. The primary exogenous drivers for the module are housing starts by type

197

Industrial Demand Module  

Gasoline and Diesel Fuel Update (EIA)

The NEMS Industrial Demand Module estimates energy consumption by energy source (fuels and The NEMS Industrial Demand Module estimates energy consumption by energy source (fuels and feedstocks) for 12 manufacturing and 6 nonmanufacturing industries. The manufacturing industries are further subdivided into the energy-intensive manufacturing industries and nonenergy-intensive manufacturing industries. The manufacturing industries are modeled through the use of a detailed process flow or end use accounting procedure, whereas the nonmanufacturing industries are modeled with substantially less detail (Table 17). The Industrial Demand Module forecasts energy consumption at the four Census region level (see Figure 5); energy consumption at the Census Division level is estimated by allocating the Census region forecast using the SEDS 27 data.

198

Microgrid Dispatch for Macrogrid Peak-Demand Mitigation  

E-Print Network (OSTI)

of 2009 SRJ Electricity Bills DER-CAM Optimization Managingthe composition of 2009 electricity bills at SRJ. Note thatTable 2 August Electricity Bill by Storage Schedule Charge

DeForest, Nicholas

2013-01-01T23:59:59.000Z

199

Demand Response In California  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Efficiency & Energy Efficiency & Demand Response Programs Dian M. Grueneich, Commissioner Dian M. Grueneich, Commissioner California Public Utilities Commission California Public Utilities Commission FUPWG 2006 Fall Meeting November 2, 2006 Commissioner Dian M. Grueneich November 2, 2006 1 Highest Priority Resource Energy Efficiency is California's highest priority resource to: Meet energy needs in a low cost manner Aggressively reduce GHG emissions November 2, 2006 2 Commissioner Dian M. Grueneich November 2, 2006 3 http://www.cpuc.ca.gov/PUBLISHED/REPORT/51604.htm Commissioner Dian M. Grueneich November 2, 2006 4 Energy Action Plan II Loading order continued "Pursue all cost-effective energy efficiency, first." Strong demand response and advanced metering

200

Travel Demand Modeling  

SciTech Connect

This chapter describes the principal types of both passenger and freight demand models in use today, providing a brief history of model development supported by references to a number of popular texts on the subject, and directing the reader to papers covering some of the more recent technical developments in the area. Over the past half century a variety of methods have been used to estimate and forecast travel demands, drawing concepts from economic/utility maximization theory, transportation system optimization and spatial interaction theory, using and often combining solution techniques as varied as Box-Jenkins methods, non-linear multivariate regression, non-linear mathematical programming, and agent-based microsimulation.

Southworth, Frank [ORNL; Garrow, Dr. Laurie [Georgia Institute of Technology

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "kw billing demand" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Automated Demand Response Today  

Science Conference Proceedings (OSTI)

Demand response (DR) has progressed over recent years beyond manual and semi-automated DR to include growing implementation and experience with fully automated demand response (AutoDR). AutoDR has been shown to be of great value over manual and semi-automated DR because it reduces the need for human interactions and decisions, and it increases the speed and reliability of the response. AutoDR, in turn, has evolved into the specification known as OpenADR v1.0 (California Energy Commission, PIER Program, C...

2012-03-29T23:59:59.000Z

202

United States lubricant demand  

Science Conference Proceedings (OSTI)

This paper examines United States Lubricant Demand for Automotive and Industrial Lubricants by year from 1978 to 1992 and 1997. Projected total United States Lubricant Demand for 1988 is 2,725 million (or MM) gallons. Automotive oils are expected to account for 1,469MM gallons or (53.9%), greases 59MM gallons (or 2.2%), and Industrial oils will account for the remaining 1,197MM gallons (or 43.9%) in 1988. This proportional relationship between Automotive and Industrial is projected to remain relatively constant until 1992 and out to 1997. Projections for individual years between 1978 to 1992 and 1997 are summarized.

Solomon, L.K.; Pruitt, P.R.

1988-01-01T23:59:59.000Z

203

ACHIEVING 800 KW CW BEAM POWER AND CONTINUING ENERGY IMPROVEMENTS IN CEBAF*  

E-Print Network (OSTI)

ACHIEVING 800 KW CW BEAM POWER AND CONTINUING ENERGY IMPROVEMENTS IN CEBAF* C. E. Reece Thomas, CEBAF at Jefferson Lab has demonstrated its full capacity of sustained 800 kW beam power. All systems the energy reach of CEBAF, we began a program of processing all installed cryomodules. This processing has

204

Generator set, 100kW frequency converter. Final technical report  

SciTech Connect

The Contractor shall furnish all engineering labor, tools, services, supplies, materials, equipment, and facilities necessary to perform an investigation and study of means to extend the capability of the contractor's existing Power Center Inverter System to the 100 kW level. This 100 kW Inverter System shall meet the basic performance parameters of the frequency converter.

Corry, T.

1975-07-01T23:59:59.000Z

205

Demand Response Valuation Frameworks Paper  

E-Print Network (OSTI)

No. ER06-615-000 CAISO Demand Response Resource User Guide -8 2.1. Demand Response Provides a Range of Benefits to8 2.2. Demand Response Benefits can be Quantified in Several

Heffner, Grayson

2010-01-01T23:59:59.000Z

206

Photo of the Week: Argonne's 10 kW Wind Turbine | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Photo of the Week: Argonne's 10 kW Wind Turbine Photo of the Week: Argonne's 10 kW Wind Turbine Photo of the Week: Argonne's 10 kW Wind Turbine November 9, 2012 - 11:57am Addthis At Argonne National Laboratory, the power generated by this 10 kW wind turbine helps scientists and engineers study the interaction of wind energy, electric vehicle charging and grid technology. The turbine is also estimated to offset more than 10 metric tons of greenhouse gas emissions annually. Learn more about renewable energy research at Argonne. | Photo courtesy of Argonne National Laboratory. At Argonne National Laboratory, the power generated by this 10 kW wind turbine helps scientists and engineers study the interaction of wind

207

Site Visit Report, Hanford Sludge Treatment Project 105-KW - August 2011 |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Sludge Treatment Project 105-KW - August Sludge Treatment Project 105-KW - August 2011 Site Visit Report, Hanford Sludge Treatment Project 105-KW - August 2011 August 2011 Hanford Sludge Treatment Project 105-KW Final Safety Analysis Report Review This report documents the results of a review conducted by the Office of Health, Safety and Security (HSS) of selected aspects of the 105-KW Basin Final Safety Analysis Report (HNF-SD-WM-SAR-062, Revision 14C) for the Sludge Treatment Project at the Hanford Site. HSS's review of the K-West Basin FSAR found it to be generally adequate with respect to the scope of this review. However, some aspects of the FSAR accident analyses of two events may warrant further review: MCO transport cask drop into the K-Basin, and the fire accident event involving the cask

208

On Demand Guarantees in Iran.  

E-Print Network (OSTI)

??On Demand Guarantees in Iran This thesis examines on demand guarantees in Iran concentrating on bid bonds and performance guarantees. The main guarantee types and… (more)

Ahvenainen, Laura

2009-01-01T23:59:59.000Z

209

Transportation Demand Management Plan  

E-Print Network (OSTI)

Transportation Demand Management Plan FALL 2009 #12;T r a n s p o r t a t i o n D e m a n d M a n the transportation impacts the expanded enrollment will have. Purpose and Goal The primary goal of the TDM plan is to ensure that adequate measures are undertaken and maintained to minimize the transportation impacts

210

Commercial Sector Demand Module  

Reports and Publications (EIA)

Documents the objectives, analytical approach and development of the National Energy Modeling System (NEMS) Commercial Sector Demand Module. The report catalogues and describes the model assumptions, computational methodology, parameter estimation techniques, model source code, and forecast results generated through the synthesis and scenario development based on these components.

Kevin Jarzomski

2012-11-15T23:59:59.000Z

211

Commercial Sector Demand Module  

Reports and Publications (EIA)

Documents the objectives, analytical approach and development of the National Energy Modeling System (NEMS) Commercial Sector Demand Module. The report catalogues and describes the model assumptions, computational methodology, parameter estimation techniques, model source code, and forecast results generated through the synthesis and scenario development based on these components.

Kevin Jarzomski

2013-10-10T23:59:59.000Z

212

Photovoltaic-based Demand Response and Ancillary Services  

NLE Websites -- All DOE Office Websites (Extended Search)

Photovoltaic-based Demand Response and Ancillary Services Photovoltaic-based Demand Response and Ancillary Services Speaker(s): Bill Vogel Date: June 22, 2012 - 1:00pm Location: 90-1099 Seminar Host/Point of Contact: David S. Watson This presentation describes innovations in intelligent micro inverters for use with photovoltaic (PV) systems. The micro-inverters enable remotely adjustable phase angles (+/- up to 45 degrees). The technology includes dynamic impedance matching and ultra-low cost dynamic reactive power management of digital power sources. These attributes can help mitigate grid balancing challenges introduced by most renewable generation resources as we strive to reach aggressive renewable portfolio standards and their associated needs for voltage support and ancillary services. The software-enabled device eliminates several pieces of heavy equipment needed

213

Rates and technologies for mass-market demand response  

Science Conference Proceedings (OSTI)

Demand response programs are often quickly and poorlycrafted in reaction to an energy crisis and disappear once the crisissubsides, ensuring that the electricity system will be unprepared whenthe next crisis hits. In this paper, we propose to eliminate theevent-driven nature of demand response programs by considering demandresponsiveness a component of the utility obligation to serve. As such,demand response can be required as a condition of service, and theoffering of demand response rates becomes a requirement of utilities asan element of customer service. Using this foundation, we explore thecosts and benefits of a smart thermostat-based demand response systemcapable of two types of programs: (1) a mandatory, system-operatorcontrolled, contingency program, and (2) a voluntary, customercontrolled, bill management program with rate-based incentives. Anydemand response program based on this system could consist of either orboth of these components. Ideally, these programs would be bundled,providing automatic load management through customer-programmed priceresponse, plus up to 10 GW of emergency load shedding capability inCalifornia. Finally, we discuss options for and barriers toimplementation of such a program in California.

Herter, Karen; Levy, Roger; Wilson, John; Rosenfeld, Arthur

2002-07-21T23:59:59.000Z

214

Data:F6898a25-9ebc-44b4-a4ba-cd54152b8724 | Open Energy Information  

Open Energy Info (EERE)

98a25-9ebc-44b4-a4ba-cd54152b8724 98a25-9ebc-44b4-a4ba-cd54152b8724 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Rappahannock Electric Coop Effective date: 2009/11/01 End date if known: Rate name: LARGE POWER SERVICE SCHEDULE LP-1 V2 Sector: Industrial Description: APPLICABILITY Applicable to all Customers along the lines of the Cooperative contracting for a load of 100 kW or more. Demand Delivery Charges: First 100 kW of billing demand delivered @ $1.50 per kW Next 400 kW of billing demand delivered @ $1.25 per kW Next 1,500 kW of billing demand delivered @ $1.10 per kW Over 2,000 kW of billing demand delivered @ $1.00 per kW All kW of ESS Billing Demand @ $ 8.15 per kW

215

Data:E5dc240a-b02f-4b5b-8aff-57827669537b | Open Energy Information  

Open Energy Info (EERE)

dc240a-b02f-4b5b-8aff-57827669537b dc240a-b02f-4b5b-8aff-57827669537b No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: High Plains Power Inc Effective date: 2007/01/01 End date if known: Rate name: LARGE POWER 500kW OR GREATER TIME OF USE Sector: Industrial Description: Applicable to all members of the Association in all areas of the Association's system to the extent that appropriate facilities exist or it is feasible to install them, for three-phase general purpose loads of 500kW or greater. NCP Demand Charge: $5.75 per kW of NCP Billing Demand MCP Demand Charge: $18.98 per kW of MCP Billing Demand NCP BILLING DEMAND: The NCP Billing Demand shall be the maximum kilowatt demand established by the consumer during the month for which the bill is rendered, as indicated or recorded by a demand meter and adjusted for power factor as provided below. MCP BILLING DEMAND: The MCP Billing Demand shall be the maximum kilowatt demand established by the consumer coincident with the Association's coincident peak billing demand, as indicated or recorded by a demand meter and adjusted for power factor as provided below.

216

Commercial Demand Module  

Gasoline and Diesel Fuel Update (EIA)

4 4 The commercial module forecasts consumption by fuel 15 at the Census division level using prices from the NEMS energy supply modules, and macroeconomic variables from the NEMS Macroeconomic Activity Module (MAM), as well as external data sources (technology characterizations, for example). Energy demands are forecast for ten end-use services 16 for eleven building categories 17 in each of the nine Census divisions (see Figure 5). The model begins by developing forecasts of floorspace for the 99 building category and Census division combinations. Next, the ten end-use service demands required for the projected floorspace are developed. The electricity generation and water and space heating supplied by distributed generation and combined heat and power technologies are projected. Technologies are then

217

Industrial Demand Module  

Gasoline and Diesel Fuel Update (EIA)

This page intentionally left blank This page intentionally left blank 51 U.S. Energy Information Administration | Assumptions to the Annual Energy Outlook 2011 Industrial Demand Module The NEMS Industrial Demand Module estimates energy consumption by energy source (fuels and feedstocks) for 15 manufacturing and 6 non-manufacturing industries. The manufacturing industries are further subdivided into the energy- intensive manufacturing industries and nonenergy-intensive manufacturing industries (Table 6.1). The manufacturing industries are modeled through the use of a detailed process-flow or end-use accounting procedure, whereas the non- manufacturing industries are modeled with substantially less detail. The petroleum refining industry is not included in the Industrial Module, as it is simulated separately in the Petroleum Market Module of NEMS. The Industrial Module calculates

218

On Demand Paging Using  

E-Print Network (OSTI)

The power consumption of the network interface plays a major role in determining the total operating lifetime of wireless handheld devices. On demand paging has been proposed earlier to reduce power consumption in cellular networks. In this scheme, a low power secondary radio is used to wake up the higher power radio, allowing the latter to sleep or remain off for longer periods of time. In this paper we present use of Bluetooth radios to serve as a paging channel for the 802.11 wireless LAN. We have implemented an on-demand paging scheme on a WLAN consisting of iPAQ PDAs equipped with Bluetooth radios and Cisco Aironet wireless networking cards. Our results show power saving ranging from 19% to 46% over the present 802.11b standard operating modes with negligible impact on performance.

Bluetooth Radios On; Yuvraj Agarwal; Rajesh K. Gupta

2003-01-01T23:59:59.000Z

219

ENERGY DEMAND FORECAST METHODS REPORT  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION ENERGY DEMAND FORECAST METHODS REPORT Companion Report to the California Energy Demand 2006-2016 Staff Energy Demand Forecast Report STAFFREPORT June 2005 CEC-400 .......................................................................................................................................1-1 ENERGY DEMAND FORECASTING AT THE CALIFORNIA ENERGY COMMISSION: AN OVERVIEW

220

Demand Forecast INTRODUCTION AND SUMMARY  

E-Print Network (OSTI)

Demand Forecast INTRODUCTION AND SUMMARY A 20-year forecast of electricity demand is a required of any forecast of electricity demand and developing ways to reduce the risk of planning errors that could arise from this and other uncertainties in the planning process. Electricity demand is forecast

Note: This page contains sample records for the topic "kw billing demand" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Net Demand3 Production  

E-Print Network (OSTI)

Contract Number: DE-FE0004002 (Subcontract: S013-JTH-PPM4002 MOD 00) Summary The US DOE has identified a number of materials that are both used by clean energy technologies and are at risk of supply disruptions in the short term. Several of these materials, especially the rare earth elements (REEs) yttrium, cerium, and lanthanum were identified by DOE as critical (USDOE 2010) and are crucial to the function and performance of solid oxide fuel cells (SOFCs) 1. In addition, US DOE has issued a second Request For Information regarding uses of and markets for these critical materials (RFI;(USDOE 2011)). This report examines how critical materials demand for SOFC applications could impact markets for these materials and vice versa, addressing categories 1,2,5, and 6 in the RFI. Category 1 – REE Content of SOFC Yttria (yttrium oxide) is the only critical material (as defined for the timeframe of interest for SOFC) used in SOFC 2. Yttrium is used as a dopant in the SOFC’s core ceramic cells.. In addition, continuing developments in SOFC technology will likely further reduce REE demand for SOFC, providing credible scope for at least an additional 50 % reduction in REE use if desirable. Category 2 – Supply Chain and Market Demand SOFC developers expect to purchase

J. Thijssen Llc

2011-01-01T23:59:59.000Z

222

Small Business Demand Response with Communicating Thermostats: SMUD's Summer Solutions Research Pilot  

E-Print Network (OSTI)

unusually high electricity bills, based on the assumptionthe highest electricity bills. These businesses are likelypast 5 or 6 p.m. Electricity bills for retail businesses are

Herter, Karen

2010-01-01T23:59:59.000Z

223

When it comes to Demand Response, is FERC its Own Worst Enemy?  

E-Print Network (OSTI)

from a lower annual electricity bill when they reduce theirhave higher annual electricity bills relative to customershigher annual electricity bills. We again emphasize that

Bushnell, James; Hobbs, Benjamin; Wolak, Frank A.

2009-01-01T23:59:59.000Z

224

California DREAMing: the design of residential demand responsive technology with people in mind  

E-Print Network (OSTI)

for those who pay an electricity bill and had experienceyour household  electricity bill.   Question  Affordable:about   your household electricity bill.   #  Question  5 

Peffer, Therese E.

2009-01-01T23:59:59.000Z

225

Estimating Demand Response Market Potential Among Large Commercialand Industrial Customers:A Scoping Study  

SciTech Connect

Demand response is increasingly recognized as an essentialingredient to well functioning electricity markets. This growingconsensus was formalized in the Energy Policy Act of 2005 (EPACT), whichestablished demand response as an official policy of the U.S. government,and directed states (and their electric utilities) to considerimplementing demand response, with a particular focus on "price-based"mechanisms. The resulting deliberations, along with a variety of stateand regional demand response initiatives, are raising important policyquestions: for example, How much demand response is enough? How much isavailable? From what sources? At what cost? The purpose of this scopingstudy is to examine analytical techniques and data sources to supportdemand response market assessments that can, in turn, answer the secondand third of these questions. We focus on demand response for large(>350 kW), commercial and industrial (C&I) customers, althoughmany of the concepts could equally be applied to similar programs andtariffs for small commercial and residential customers.

Goldman, Charles; Hopper, Nicole; Bharvirkar, Ranjit; Neenan,Bernie; Cappers, Peter

2007-01-01T23:59:59.000Z

226

California Energy Demand Scenario Projections to 2050  

E-Print Network (OSTI)

Natural Gas Demands..xi Annual natural gas demand for each alternativeused in natural gas demand projections. 34

McCarthy, Ryan; Yang, Christopher; Ogden, Joan M.

2008-01-01T23:59:59.000Z

227

Monitoring System Used to Identify, Track and Allocate Peak Demand Costs  

E-Print Network (OSTI)

In 1994, Thomson Consumer Electronics (RCA) purchased a UtiliTRACK® Monitoring System for a plant in Indianapolis, Indiana primarily to allow utility costs to be billed to individual departments within Thomson as well as to outside organizations leasing space on the site. The most common way to distribute monthly electric costs within a facility when consumption by area or department is available through submetering or other means, is to apply the average cost per KWH from the utility bill to the individual consumption figures. Thomson initially used the data from the UtiliTRACK System in this way. As the plant engineer worked with system data on a daily basis and began to develop a much better understanding of the plant's electrical profile, it was clear that the percentage contribution by department or area to the plant's peak demand was not the same as that assigned based solely upon consumption. With a monthly peak exceeding 8 MW and peak demand charges accounting for more than 60% of the monthly electric bill, he realized that to be accurate and fair, costs must be allocated based both on consumption and peak demand. He asked UtiliTRACK to develop a method for tracking and allocating peak demand costs. The resulting software continuously tracks the total plant demand (the sum of 3 utility meters) and records the contribution of each monitored point at the time the peak occurs. The resulting reports and graphs not only enable the owner to accurately allocate peak demand costs but also provide a means for tracking and managing peaks on a continuous basis.

Holmes, W. A.

1998-04-01T23:59:59.000Z

228

California Energy Demand Scenario Projections to 2050  

E-Print Network (OSTI)

Minimum demand and Maximum demand incorporate assumptionslevels, or very minor Maximum demand household size, growthvehicles in Increasing Maximum demand 23 mpg truck share

McCarthy, Ryan; Yang, Christopher; Ogden, Joan M.

2008-01-01T23:59:59.000Z

229

Ingersoll Rand VSD Oil Injected Screw Air Compressor (37-75kW ...  

U.S. Energy Information Administration (EIA)

Ingersoll Rand VSD Oil Injected Screw Air Compressor (37-75kW / 50-100HP VSD),Kunshan CompAirs Machinery Plant Co.,Ltd is the leading air compressor ...

230

225-kW Dynamometer for Testing Small Wind Turbine Components: Preprint  

DOE Green Energy (OSTI)

This paper describes NREL's new 225-kW dynamometer facility that is suitable for testing a variety of components and subsystems for small wind turbines and discusses opportunities for industry partnerships with NREL for use of the facility.

Green, J.

2006-06-01T23:59:59.000Z

231

Dividends with Demand Response  

SciTech Connect

To assist facility managers in assessing whether and to what extent they should participate in demand response programs offered by ISOs, we introduce a systematic process by which a curtailment supply curve can be developed that integrates costs and other program provisions and features. This curtailment supply curve functions as bid curve, which allows the facility manager to incrementally offer load to the market under terms and conditions acceptable to the customer. We applied this load curtailment assessment process to a stylized example of an office building, using programs offered by NYISO to provide detail and realism.

Kintner-Meyer, Michael CW; Goldman, Charles; Sezgen, O.; Pratt, D.

2003-10-31T23:59:59.000Z

232

Comparison groups on bills: Automated, personalized energy information  

NLE Websites -- All DOE Office Websites (Extended Search)

Buildings Cool Roofs and Heat Islands Demand Response Energy Efficiency Program and Market Trends High Technology and Industrial Systems Lighting Systems Residential Buildings...

233

Chinese demand drives global deforestation Chinese demand drives global deforestation  

E-Print Network (OSTI)

Chinese demand drives global deforestation Chinese demand drives global deforestation By Tansa Musa zones and do not respect size limits in their quest for maximum financial returns. "I lack words economy. China's demand for hardwood drives illegal logging says "Both illegal and authorized

234

Estimating a Demand System with Nonnegativity Constraints: Mexican Meat Demand  

E-Print Network (OSTI)

: Properties of the AIDS Generalized Maximum Entropy Estimator 24 #12;Estimating a Demand SystemEstimating a Demand System with Nonnegativity Constraints: Mexican Meat Demand Amos Golan* Jeffrey with nonnegativity constraints is presented. This approach, called generalized maximum entropy (GME), is more

Perloff, Jeffrey M.

235

CALIFORNIA ENERGY DEMAND 2006-2016 STAFF ENERGY DEMAND FORECAST  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION CALIFORNIA ENERGY DEMAND 2006-2016 STAFF ENERGY DEMAND FORECAST Demand Forecast report is the product of the efforts of many current and former California Energy Commission staff. Staff contributors to the current forecast are: Project Management and Technical Direction

236

The Potential Impact of Increased Renewable Energy Penetrations on Electricity Bill Savings from Residential Photovoltaic Systems  

E-Print Network (OSTI)

of rate design and net metering on the bill savings fromelectricity rate through net metering. Given the uncertaintyunder two types of net metering, for each scenario. Results

Barbose, Galen

2013-01-01T23:59:59.000Z

237

The Potential Impact of Increased Renewable Energy Penetrations on Electricity Bill Savings from Residential Photovoltaic Systems  

E-Print Network (OSTI)

impact of rate design and net metering on the bill savingselectricity rate through net metering. Given the uncertaintyunder two types of net metering, for each scenario. Results

Barbose, Galen

2013-01-01T23:59:59.000Z

238

Where can I get help paying my utility bills? - FAQ - U.S. Energy ...  

U.S. Energy Information Administration (EIA)

Where can I get help paying my utility bills? The U.S. Department of Health and Human Services' Low Income Home Energy Assistance Program (LIHEAP) provides federally ...

239

Demand Response | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

Demand Response Demand Response Demand Response Demand Response Demand response provides an opportunity for consumers to play a significant role in the operation of the electric grid by reducing or shifting their electricity usage during peak periods in response to time-based rates or other forms of financial incentives. Demand response programs are being used by electric system planners and operators as resource options for balancing supply and demand. Such programs can lower the cost of electricity in wholesale markets, and in turn, lead to lower retail rates. Methods of engaging customers in demand response efforts include offering time-based rates such as time-of-use pricing, critical peak pricing, variable peak pricing, real time pricing, and critical peak rebates. It also includes direct load control programs which provide the

240

ELECTRICITY DEMAND FORECAST COMPARISON REPORT  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION ELECTRICITY DEMAND FORECAST COMPARISON REPORT STAFFREPORT June 2005 ..............................................................................3 Residential Forecast Comparison ..............................................................................................5 Nonresidential Forecast Comparisons

Note: This page contains sample records for the topic "kw billing demand" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Overview of Demand Response  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

08 PJM 08 PJM www.pjm.com ©2003 PJM Overview of Demand Response PJM ©2008 PJM www.pjm.com ©2003 PJM Growth, Statistics, and Current Footprint AEP, Dayton, ComEd, & DUQ Dominion Generating Units 1,200 + Generation Capacity 165,000 MW Peak Load 144,644 MW Transmission Miles 56,070 Area (Square Miles) 164,250 Members 500 + Population Served 51 Million Area Served 13 States and DC Generating Units 1,200 + Generation Capacity 165,000 MW Peak Load 144,644 MW Transmission Miles 56,070 Area (Square Miles) 164,250 Members 500 + Population Served 51 Million Area Served 13 States and DC Current PJM RTO Statistics Current PJM RTO Statistics PJM Mid-Atlantic Integrations completed as of May 1 st , 2005 ©2008 PJM

242

Autimated Price and Demand Response Demonstration for Large Customers in New York City using OpenADR  

E-Print Network (OSTI)

Open Automated Demand Response (OpenADR), an XML-based information exchange model, is used to facilitate continuous price-responsive operation and demand response participation for large commercial buildings in New York who are subject to the default day-ahead hourly pricing. We summarize the existing demand response programs in New York and discuss OpenADR communication, prioritization of demand response signals, and control methods. Building energy simulation models are developed and field tests are conducted to evaluate continuous energy management and demand response capabilities of two commercial buildings in New York City. Preliminary results reveal that providing machine-readable prices to commercial buildings can facilitate both demand response participation and continuous energy cost savings. Hence, efforts should be made to develop more sophisticated algorithms for building control systems to minimize customer's utility bill based on price and reliability information from the electricity grid.

Kim, J. J.; Yin, R.; Kiliccote, S.

2013-01-01T23:59:59.000Z

243

Oxygenate Supply/Demand Balances  

Gasoline and Diesel Fuel Update (EIA)

Oxygenate Supply/Demand Oxygenate Supply/Demand Balances in the Short-Term Integrated Forecasting Model By Tancred C.M. Lidderdale This article first appeared in the Short-Term Energy Outlook Annual Supplement 1995, Energy Information Administration, DOE/EIA-0202(95) (Washington, DC, July 1995), pp. 33-42, 83-85. The regression results and historical data for production, inventories, and imports have been updated in this presentation. Contents * Introduction o Table 1. Oxygenate production capacity and demand * Oxygenate demand o Table 2. Estimated RFG demand share - mandated RFG areas, January 1998 * Fuel ethanol supply and demand balance o Table 3. Fuel ethanol annual statistics * MTBE supply and demand balance o Table 4. EIA MTBE annual statistics * Refinery balances

244

Participants: William Naughton, COHMED Bill Sherman, NE HLRW Task Force  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

conference call May 27, 1998 conference call May 27, 1998 Participants: William Naughton, COHMED Bill Sherman, NE HLRW Task Force Bob Fronczak, AAR Mike Butler, UETC Ray English, DOE-NR George Ruberg, UETC Kevin Blackwell, FRA Markus Popa, DOE-RW Sandy Covi, UP The Rail Topic Group is currently in a transitional mode, moving simultaneously toward closure of the two rail information matrices, Comparison of CVSA Recommended National Procedures and Out-Of-Service Criteria for the Enhanced Safety Inspection of Commercial Highway Vehicles Transporting Transuranics, Spent Nuclear Fuel, and High Level Waste to Rail Inspection Standards, and Rail and Highway Regulations Relative to the Transportation of Radioactive Materials and their Applicability to States, Tribes, Shippers, and Carriers, (both

245

"2012 Average Monthly Bill- Residential"  

U.S. Energy Information Administration (EIA) Indexed Site

Residential" Residential" "(Data from forms EIA-861- schedules 4A-D, EIA-861S and EIA-861U)" "State","Number of Customers","Average Monthly Consumption (kWh)","Average Price (cents/kWh)","Average Monthly Bill (Dollar and cents)" "New England",6203726,634.13095,15.713593,99.644755 "Connecticut",1454651,730.85302,17.343298,126.75402 "Maine",703770,530.56349,14.658797,77.774225 "Massachusetts",2699141,627.15845,14.912724,93.52641 "New Hampshire",601697,614.81776,16.070168,98.802249 "Rhode Island",435448,597.34783,14.404061,86.042344 "Vermont",309019,565.03618,17.006075,96.090478 "Middle Atlantic",15727423,700.63673,15.272654,107.00582

246

On Bill Financing: SDG&E/SoCalGas  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2 San Diego Gas and Electric Co. and Southern California Gas Company. All copyright and trademark rights reserved. 2 San Diego Gas and Electric Co. and Southern California Gas Company. All copyright and trademark rights reserved. On Bill Financing: SDG&E / SoCalGas Frank Spasaro May 6, 2011 US - China Energy Efficiency Forum OVERVIEW of SDG&E / Southern California Gas * Covers most of the southern parts of California: * 24, 000 square miles * Over 24 million residents * 1.4 million electric meters * 6.65 million gas meters (850k + 5.8 million) California's Energy Action Plan II * In 2005, the CPUC and CEC'S EAP II declared: "[The} goal is for California's energy to be adequate, affordable, technologically advanced, and environmentally sound...[C]ost effective

247

"2012 Average Monthly Bill- Industrial"  

U.S. Energy Information Administration (EIA) Indexed Site

Industrial" Industrial" "(Data from forms EIA-861- schedules 4A-D, EIA-861S and EIA-861U)" "State","Number of Customers","Average Monthly Consumption (kWh)","Average Price (cents/kWh)","Average Monthly Bill (Dollar and cents)" "New England",34164,67854.037,11.83487,8030.4373 "Connecticut",4647,63947.063,12.672933,8103.9685 "Maine",2780,90741.457,7.9819499,7242.9376 "Massachusetts",21145,66710.826,12.566635,8383.3057 "New Hampshire",3444,47247.217,11.83228,5590.423 "Rhode Island",1927,39935.911,10.676724,4263.8471 "Vermont",221,536044.12,9.9796777,53495.475 "Middle Atlantic",45836,126368.14,7.4903534,9465.42 "New Jersey",12729,50817.89,10.516509,5344.2677

248

Streaming workload generator for testing billing mediation platform in telecom industry  

Science Conference Proceedings (OSTI)

Billing Mediation Platform (BMP) in Telco is used to process real-time streams of Call Detail Records (CDRs) which can number tens of billions a day. The comprehensive records generated by BMPs can be used for billing and accounting, fraud detection, ...

Eric Bouillet; Parijat Dube

2010-12-01T23:59:59.000Z

249

SmartCharge: cutting the electricity bill in smart homes with energy storage  

Science Conference Proceedings (OSTI)

Market-based electricity pricing provides consumers an opportunity to lower their electric bill by shifting consumption to low price periods. In this paper, we explore how to lower electric bills without requiring consumer involvement using an intelligent ... Keywords: battery, electricity, energy, grid

Aditya Mishra; David Irwin; Prashant Shenoy; Jim Kurose; Ting Zhu

2012-05-01T23:59:59.000Z

250

The Impact of Rate Design and Net Metering on the Bill Savings from  

E-Print Network (OSTI)

LBNL-3276E The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV Energy (Solar Energy Technologies Program) and the Office of Electricity Delivery and Energy Reliability of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers

251

Demand Response Programs, 6. edition  

Science Conference Proceedings (OSTI)

The report provides a look at the past, present, and future state of the market for demand/load response based upon market price signals. It is intended to provide significant value to individuals and companies who are considering participating in demand response programs, energy providers and ISOs interested in offering demand response programs, and consultants and analysts looking for detailed information on demand response technology, applications, and participants. The report offers a look at the current Demand Response environment in the energy industry by: defining what demand response programs are; detailing the evolution of program types over the last 30 years; discussing the key drivers of current initiatives; identifying barriers and keys to success for the programs; discussing the argument against subsidization of demand response; describing the different types of programs that exist including:direct load control, interruptible load, curtailable load, time-of-use, real time pricing, and demand bidding/buyback; providing examples of the different types of programs; examining the enablers of demand response programs; and, providing a look at major demand response programs.

NONE

2007-10-15T23:59:59.000Z

252

Energy Efficiency Tricks to Stop Your Energy Bill from Haunting You |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tricks to Stop Your Energy Bill from Haunting You Tricks to Stop Your Energy Bill from Haunting You Energy Efficiency Tricks to Stop Your Energy Bill from Haunting You October 21, 2013 - 2:07pm Addthis This Halloween, keep ghosts and goblins at bay -- while saving energy and money -- with these home energy efficiency tricks. | Infographic by Sarah Gerrity, Energy Department. This Halloween, keep ghosts and goblins at bay -- while saving energy and money -- with these home energy efficiency tricks. | Infographic by Sarah Gerrity, Energy Department. Rebecca Matulka Rebecca Matulka Digital Communications Specialist, Office of Public Affairs What are the key facts? The typical American family spends at least $2,000 a year on their home energy bills. Families can save up to 20-30 percent on their energy bills by

253

Bodman Statement on House Passage of Energy Bill | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

House Passage of Energy Bill House Passage of Energy Bill Bodman Statement on House Passage of Energy Bill April 21, 2005 - 10:57am Addthis Washington, DC - Energy Secretary Samuel W. Bodman released the following statement today regarding House passage of energy legislation: "I congratulate the House of Representatives for passing comprehensive energy legislation. This bill will put us on a path to affordable and reliable supplies of energy in the future by improving energy efficiency; increasing domestic energy supplies; diversifying our energy sources to include more renewable energy sources; and modernizing our energy delivery system. For the good of American families, the American economy and America's national security, I call on the Senate to pass energy legislation and get a bill to the President's desk by this summer."

254

Bill Richardson Sworn in as Secretary of Energy | National Nuclear Security  

National Nuclear Security Administration (NNSA)

Bill Richardson Sworn in as Secretary of Energy | National Nuclear Security Bill Richardson Sworn in as Secretary of Energy | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > About Us > Our History > NNSA Timeline > Bill Richardson Sworn in as Secretary of Energy Bill Richardson Sworn in as Secretary of Energy August 18, 1998 Washington, DC Bill Richardson Sworn in as Secretary of Energy

255

Addressing Energy Demand through Demand Response: International Experiences and Practices  

E-Print Network (OSTI)

2007 EMCS EPACT ERCOT FCM FERC FRCC demand side managementEnergy Regulatory Commission (FERC). EPAct began the processin wholesale markets, which FERC Order 888 furthered by

Shen, Bo

2013-01-01T23:59:59.000Z

256

STATEMENT OF CONSIDERATIONS REQUEST BY KENETECH WINDPOWER, INC. (KW) FOR AN  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

KENETECH WINDPOWER, INC. (KW) FOR AN KENETECH WINDPOWER, INC. (KW) FOR AN ADVANCE WAIVER OF DOMESTIC AND FOREIGN PATENT RIGHTS UNDER NREL SUBCONTRACT NO: AAA-5-13320-02 UNDER DOE CONTRACT NO: DE-AC36-83CH10093 W(A)-95-003; CH-0849 Kenetech Windpower, Inc. (KW) has requested a waiver of domestic and foreign patent rights for all subject inventions arisg from the above referenced subcontract entitled "Advanced Wind Turbine Program Next Generation Turbine Development Project." The objective of the work to be performed under this subcontract is to design and develop an advanced next generation wind turbine capable of producing electricity for $0.04/kWh or less at 5.8 m/s(13mph) sites in the 1998-2000 time period. The work is to proceed in two stages. In the first stage, which is the subject of this waiver, the work comprises a concept study to develop

257

Qualified Energy Property Tax Exemption for Projects 250 kW or Less |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Qualified Energy Property Tax Exemption for Projects 250 kW or Less Qualified Energy Property Tax Exemption for Projects 250 kW or Less Qualified Energy Property Tax Exemption for Projects 250 kW or Less < Back Eligibility Commercial Utility Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Solar Home Weatherization Water Wind Program Info Start Date 01/01/2010 State Ohio Program Type Property Tax Incentive Rebate Amount 100% exemption Provider Ohio Development Services Agency Ohio's Renewable and Advanced Energy Project Property Tax Exemption, enacted with the passage of Ohio S.B. 232 in the summer of 2010, exempts qualified energy projects in Ohio from public utility tangible personal property taxes and real property taxes*. Before passage of S.B. 232, a renewable energy facility in Ohio that sold electricity to a third-party

258

Qualified Energy Property Tax Exemption for Projects over 250 kW (Payment  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Qualified Energy Property Tax Exemption for Projects over 250 kW Qualified Energy Property Tax Exemption for Projects over 250 kW (Payment in Lieu) Qualified Energy Property Tax Exemption for Projects over 250 kW (Payment in Lieu) < Back Eligibility Commercial Utility Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Solar Wind Program Info Start Date 01/01/2010 State Ohio Program Type Property Tax Incentive Rebate Amount 100% property tax exemption; payment in lieu of tax required Provider Ohio Development Services Agency Ohio's Renewable and Advanced Energy Project Property Tax Exemption, enacted with the passage of Ohio S.B. 232 in the summer of 2010, exempts qualified energy projects in Ohio from public utility tangible personal

259

Trade Study on Aggregation of Multiple 10-KW Solid Ozide Fuel Cell Power Modules  

DOE Green Energy (OSTI)

According to the Solid State Energy Conversion Alliance (SECA) program guidelines, solid oxide fuel cells (SOFC) will be produced in the form of 3-10 kW modules for residential use. In addition to residential use, these modules can also be used in apartment buildings, hospitals, etc., where a higher power rating would be required. For example, a hospital might require a 250 kW power generating capacity. To provide this power using the SECA SOFC modules, 25 of the 10 kW modules would be required. These modules can be aggregated in different architectures to yield the necessary power. This report will show different approaches for aggregating numerous SOFC modules and will evaluate and compare each one with respect to cost, control complexity, ease of modularity, and fault tolerance.

Ozpineci, B.

2004-12-03T23:59:59.000Z

260

Laboratory Testing of Demand-Response Enabled Household Appliances  

SciTech Connect

With the advent of the Advanced Metering Infrastructure (AMI) systems capable of two-way communications between the utility's grid and the building, there has been significant effort in the Automated Home Energy Management (AHEM) industry to develop capabilities that allow residential building systems to respond to utility demand events by temporarily reducing their electricity usage. Major appliance manufacturers are following suit by developing Home Area Network (HAN)-tied appliance suites that can take signals from the home's 'smart meter,' a.k.a. AMI meter, and adjust their run cycles accordingly. There are numerous strategies that can be employed by household appliances to respond to demand-side management opportunities, and they could result in substantial reductions in electricity bills for the residents depending on the pricing structures used by the utilities to incent these types of responses.The first step to quantifying these end effects is to test these systems and their responses in simulated demand-response (DR) conditions while monitoring energy use and overall system performance.

Sparn, B.; Jin, X.; Earle, L.

2013-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "kw billing demand" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

North Wind 4-kW wind-system development. Phase II. Fabrication and test  

DOE Green Energy (OSTI)

This report presents the results of Phase II (testing and fabrication) of a program funded by the US Department of Energy to design, fabricate, and test a cost-effective wind system in the 3 to 6 kW class. During Phase II, using the design developed during Phase I, a prototype 4 kW machine was fabricated and tested in Waitsfield, Vermont. Several problems were encountered and subsequently analyzed. Design modifications, including the use of a larger alternator, are described. Test performed by North Wind and by Rockwell International (which monitored the program) demonstrated the predicted performance characteristics and the validity of the North Wind design.

Lynch, J.; Coleman, C.; Mayer, D.J.

1983-01-01T23:59:59.000Z

262

electricity demand | OpenEI  

Open Energy Info (EERE)

demand demand Dataset Summary Description The New Zealand Ministry of Economic Development publishes energy data including many datasets related to electricity. Included here are three electricity consumption and demand datasets, specifically: annual observed electricity consumption by sector (1974 to 2009); observed percentage of consumers by sector (2002 - 2009); and regional electricity demand, as a percentage of total demand (2009). Source New Zealand Ministry of Economic Development Date Released Unknown Date Updated July 03rd, 2009 (5 years ago) Keywords Electricity Consumption electricity demand energy use by sector New Zealand Data application/vnd.ms-excel icon Electricity Consumption by Sector (1974 - 2009) (xls, 46.1 KiB) application/vnd.ms-excel icon Percentage of Consumers by Sector (2002 - 2009) (xls, 43.5 KiB)

263

Annual World Oil Demand Growth  

Gasoline and Diesel Fuel Update (EIA)

6 6 Notes: Following relatively small increases of 1.3 million barrels per day in 1999 and 0.9 million barrels per day in 2000, EIA is estimating world demand may grow by 1.6 million barrels per day in 2001. Of this increase, about 3/5 comes from non-OECD countries, while U.S. oil demand growth represents more than half of the growth projected in OECD countries. Demand in Asia grew steadily during most of the 1990s, with 1991-1997 average growth per year at just above 0.8 million barrels per day. However, in 1998, demand dropped by 0.3 million barrels per day as a result of the Asian economic crisis that year. Since 1998, annual growth in oil demand has rebounded, but has not yet reached the average growth seen during 1991-1997. In the Former Soviet Union, oil demand plummeted during most of the

264

Calculating Energy and Demand Retrofit Savings for Stroman High School: Interim Report  

E-Print Network (OSTI)

As part of the LoanSTAR program, Stroman High School in Victoria Texas underwent two retrofits: a) an absorption chiller was changed to an electric vapor compression chiller, and b) an EMCS system was installed after about 5 months in the post retrofit period. Moreover, retrofit savings calculation was complex since pre-retrofit data consisted only of monthly utility data while hourly monitored data are available for the post-retrofit period. The retrofit savings in electricity and gas were computed by two different approaches: Unnormalized Utility Bill Comparison and Weather and Schedule Normalized Utility Bill Comparison Using Post-Retrofit Daily Models. (For purpose of simplicity, in this report, we will refer them as Level-0 and Level-1, respectively.) This report describes these approaches and discusses how well the retrofit savings predicted by both approaches compare with each other. It also describes the procedure for determining demand savings.

Liu, Y.; Reddy, T. A.; Katipamula, S.; Claridge, D. E.

1992-01-01T23:59:59.000Z

265

Demand Response Valuation Frameworks Paper  

E-Print Network (OSTI)

lvi Southern California Edison filed its SmartConnectinfrastructure (e.g. , Edison Electric Institute, DemandSouthern California Edison Standard Practice Manual

Heffner, Grayson

2010-01-01T23:59:59.000Z

266

Automated Demand Response and Commissioning  

NLE Websites -- All DOE Office Websites (Extended Search)

and Commissioning Title Automated Demand Response and Commissioning Publication Type Conference Paper LBNL Report Number LBNL-57384 Year of Publication 2005 Authors Piette, Mary...

267

Demand Uncertainty and Price Dispersion.  

E-Print Network (OSTI)

??Demand uncertainty has been recognized as one factor that may cause price dispersion in perfectly competitive markets with costly and perishable capacity. With the persistence… (more)

Li, Suxi

2007-01-01T23:59:59.000Z

268

1995 Demand-Side Managment  

U.S. Energy Information Administration (EIA)

U.S. Electric Utility Demand-Side Management 1995 January 1997 Energy Information Administration Office of Coal, Nuclear, Electric and Alternate Fuels

269

Demand Responsive Lighting: A Scoping Study  

E-Print Network (OSTI)

8 Figure 7: Maximum Demands Savings Intensity due toaddressed in this report. Maximum Demand Savings Intensity (Echelon Figure 7: Maximum Demands Savings Intensity due to

Rubinstein, Francis; Kiliccote, Sila

2007-01-01T23:59:59.000Z

270

Coordination of Energy Efficiency and Demand Response  

E-Print Network (OSTI)

energy efficiency and demand response programs and tariffs.energy efficiency and demand response program and tariffenergy efficiency and demand response programs and tariffs.

Goldman, Charles

2010-01-01T23:59:59.000Z

271

Wireless Demand Response Controls for HVAC Systems  

E-Print Network (OSTI)

Strategies Linking Demand Response and Energy Efficiency,”Fully Automated Demand Response Tests in Large Facilities,technical support from the Demand Response Research Center (

Federspiel, Clifford

2010-01-01T23:59:59.000Z

272

Demand Response Quick Assessment Tool (DRQAT)  

NLE Websites -- All DOE Office Websites (Extended Search)

Demand Response Quick Assessment Tool (DRQAT) The opportunities for demand reduction and cost saving with building demand responsive control vary tremendously with building type...

273

Demand Responsive Lighting: A Scoping Study  

E-Print Network (OSTI)

2 2.0 Demand ResponseFully Automated Demand Response Tests in Large Facilities,was coordinated by the Demand Response Research Center and

Rubinstein, Francis; Kiliccote, Sila

2007-01-01T23:59:59.000Z

274

Coupling Renewable Energy Supply with Deferrable Demand  

E-Print Network (OSTI)

8.4 Demand Response Integration . . . . . . . . . . .for each day type for the demand response study - moderatefor each day type for the demand response study - moderate

Papavasiliou, Anthony

2011-01-01T23:59:59.000Z

275

Installation and Commissioning Automated Demand Response Systems  

E-Print Network (OSTI)

their partnership in demand response automation research andand Techniques for Demand Response. LBNL Report 59975. Mayof Fully Automated Demand Response in Large Facilities.

Kiliccote, Sila; Global Energy Partners; Pacific Gas and Electric Company

2008-01-01T23:59:59.000Z

276

Coordination of Energy Efficiency and Demand Response  

E-Print Network (OSTI)

and D. Kathan (2009). Demand Response in U.S. ElectricityEnergy Financial Group. Demand Response Research Center [2008). Assessment of Demand Response and Advanced Metering.

Goldman, Charles

2010-01-01T23:59:59.000Z

277

Strategies for Demand Response in Commercial Buildings  

E-Print Network (OSTI)

Fully Automated Demand Response Tests in Large Facilities”of Fully Automated Demand Response in Large Facilities”,was coordinated by the Demand Response Research Center and

Watson, David S.; Kiliccote, Sila; Motegi, Naoya; Piette, Mary Ann

2006-01-01T23:59:59.000Z

278

Retail Demand Response in Southwest Power Pool  

E-Print Network (OSTI)

23 ii Retail Demand Response in SPP List of Figures and10 Figure 3. Demand Response Resources by11 Figure 4. Existing Demand Response Resources by Type of

Bharvirkar, Ranjit

2009-01-01T23:59:59.000Z

279

Option Value of Electricity Demand Response  

E-Print Network (OSTI)

Table 1. “Economic” demand response and real time pricing (Implications of Demand Response Programs in CompetitiveAdvanced Metering, and Demand Response in Electricity

Sezgen, Osman; Goldman, Charles; Krishnarao, P.

2005-01-01T23:59:59.000Z

280

Use power factor correction to cut SCR rig fuel bills  

SciTech Connect

When drilling with SCR-powered drilling rigs, there are specific instances on every well when the kVA capacity of the AC generators prohibits efficient engine loading. It then becomes necessary to run another engine-generator set to provide sufficient kVA to power the load, even though the kW required by the load can be furnished by existing engine(s) on line. The practice of running one more engine than can be fully loaded causes all engines on line to run at a less efficient point on the brake specific fuel consumption curve (BSFC) and therefore costs more in terms of engine hours, fuel and maintenance costs. This article presents a study of the load represented by the mud pump and drawworks along with a graphical representation that shows the effect of these loads on the engine generator system both with and without a power factor correction device.

Logan, R.T.

1983-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "kw billing demand" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Hanford Sludge Treatment Project 105-KW Final Safety Analysis Report Review, August 2011  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Site Visit Report Site Visit Report Sludge Treatment Project 105-KW Final Safety Analysis Report Review May 2011 August 2011 Office of Enforcement and Oversight Office of Health, Safety and Security U.S. Department of Energy Table of Contents 1.0 Introduction ............................................................................................................................................ 1 2.0 Background ............................................................................................................................................ 1 3.0 Scope ...................................................................................................................................................... 1 4.0 Results .................................................................................................................................................... 2

282

Hanford Sludge Treatment Project 105-KW Final Safety Analysis Report Review, August 2011  

NLE Websites -- All DOE Office Websites (Extended Search)

Site Visit Report Site Visit Report Sludge Treatment Project 105-KW Final Safety Analysis Report Review May 2011 August 2011 Office of Enforcement and Oversight Office of Health, Safety and Security U.S. Department of Energy Table of Contents 1.0 Introduction ............................................................................................................................................ 1 2.0 Background ............................................................................................................................................ 1 3.0 Scope ...................................................................................................................................................... 1 4.0 Results .................................................................................................................................................... 2

283

Ris-R-1480(EN) Stand-alone version of the 11kW Gaia  

E-Print Network (OSTI)

This report is part of the reporting done as part of the project "The Gaia wind turbine applied in wind diesel or all the diesel power. The requirement is that the wind power system in manyRisø-R-1480(EN) Stand-alone version of the 11kW Gaia wind turbine Henrik Bindner Pedro A.C. Rosas

284

Design considerations of a 15kW heat exchanger for the CSPonD Project  

E-Print Network (OSTI)

The objective of this work was to develop a 15 kW heat exchanger model for the CSPonD molten salt receiver that will shuttle the molten salt's thermal energy for conversion to electric power. A heat extraction system ...

Adames, Adrian A

2010-01-01T23:59:59.000Z

285

225-kW Dynamometer for Testing Small Wind Turbine Components: Preprint  

SciTech Connect

This paper describes NREL's new 225-kW dynamometer facility that is suitable for testing a variety of components and subsystems for small wind turbines and discusses opportunities for industry partnerships with NREL for use of the facility.

Green, J.

2006-06-01T23:59:59.000Z

286

100 kW CC-OTEC Plant and Deep Ocean water Applications  

E-Print Network (OSTI)

Examine multiple usage of DSW Yokogawa Electric Produce & set up electricity & control system Plant the electric grid for the first time in 15 years in the world. #12;IOES (Institute of Ocean Energy, Saga Univ.) Experiments and Demonstration by IOES (Institute of Ocean Energy, Saga University) 30 kW Electricity

287

China, India demand cushions prices  

SciTech Connect

Despite the hopes of coal consumers, coal prices did not plummet in 2006 as demand stayed firm. China and India's growing economies, coupled with solid supply-demand fundamentals in North America and Europe, and highly volatile prices for alternatives are likely to keep physical coal prices from wide swings in the coming year.

Boyle, M.

2006-11-15T23:59:59.000Z

288

Harnessing the power of demand  

Science Conference Proceedings (OSTI)

Demand response can provide a series of economic services to the market and also provide ''insurance value'' under low-likelihood, but high-impact circumstances in which grid reliablity is enhanced. Here is how ISOs and RTOs are fostering demand response within wholesale electricity markets. (author)

Sheffrin, Anjali; Yoshimura, Henry; LaPlante, David; Neenan, Bernard

2008-03-15T23:59:59.000Z

289

Driving Demand for Home Energy Improvements  

NLE Websites -- All DOE Office Websites (Extended Search)

Driving Demand for Home Energy Improvements Driving Demand for Home Energy Improvements Title Driving Demand for Home Energy Improvements Publication Type Report Year of Publication 2010 Authors Fuller, Merrian C., Cathy Kunkel, Mark Zimring, Ian M. Hoffman, Katie L. Soroye, and Charles A. Goldman Tertiary Authors Borgeson, Merrian Pagination 136 Date Published 09/2010 Publisher LBNL City Berkeley Keywords electricity markets and policy group, energy analysis and environmental impacts department Abstract Policy makers and program designers in the U.S. and abroad are deeply concerned with the question of how to scale up energy efficiency to a level that is commensurate both to the energy and climate challenges we face, and to the potential for energy savings that has been touted for decades. When policy makers ask what energy efficiency can do, the answers usually revolve around the technical and economic potential of energy efficiency-they rarely hone in on the element of energy demand that matters most for changing energy usage in existing homes: the consumer. A growing literature is concerned with the behavioral underpinnings of energy consumption. We examine a narrower, related subject: How can millions of Americans be persuaded to divert valued time and resources into upgrading their homes to eliminate energy waste, avoid high utility bills, and spur the economy? With hundreds of millions of public dollars1 flowing into incentives, workforce training, and other initiatives to support comprehensive home energy improvements2, it makes sense to review the history of these programs and begin gleaning best practices for encouraging comprehensive home energy improvements. Looking across 30 years of energy efficiency programs that targeted the residential market, many of the same issues that confronted past program administrators are relevant today: How do we cost-effectively motivate customers to take action? Who can we partner with to increase program participation? How do we get residential efficiency programs to scale? While there is no proven formula-and only limited success to date with reliably motivating large numbers of Americans to invest in comprehensive home energy improvements, especially if they are being asked to pay for a majority of the improvement costs-there is a rich and varied history of experiences that new programs can draw upon. Our primary audiences are policy makers and program designers-especially those that are relatively new to the field, such as the over 2,000 towns, cities, states, and regions who are recipients of American Reinvestment and Recovery Act funds for clean energy programs. This report synthesizes lessons from first generation programs, highlights emerging best practices, and suggests methods and approaches to use in designing, implementing, and evaluating these programs. We examined 14 residential energy efficiency programs, conducted an extensive literature review, interviewed industry experts, and surveyed residential contractors to draw out these lessons.

290

Use of electricity billing data to determine household energy use fingerprints  

Science Conference Proceedings (OSTI)

Ways to analyze billing data are discussed. The starting point for these analyses is a method developed at Princeton University. Their Scorekeeping model permits decomposition of total household energy use into its weather- and nonweather-sensitive elements; the weather-sensitive portion is assumed proportional to heating degree days. The Scorekeeping model also allows one to compute weather-adjusted energy consumption for each household based on its billing data and model parameters; this is the model's estimate of annual consumption under long-run weather conditions. The methods discussed here extend the Scorekeeping results to identify additional characteristics of household energy use. In particular, the methods classify households in terms of the intensity with which the particular fuel is used for space heating (primary heating fuel vs supplemental heating fuel vs no heating at all with the fuel). In addition, households that use the particular fuel for air conditioning are identified. In essence, the billing data and model results are used to determine household energy use fingerprints. The billing data and model results can also be used to identify and correct anomalous bills. The automated method discussed here identifies anomalously high or low utility bills, which are then dropped before re-estimation of the Scorekeeping model parameters. Alternatively, a pair of bills may be combined if one is very high and a temporally adjacent bill is very low. The Scorekeeping model is then re-estimated after the two bills are combined into one. The methods permit careful examination and analysis of changes in energy use from one year to another.

Hirst, E.; Goeltz, R.; White, D.

1984-08-01T23:59:59.000Z

291

Demand Response for Ancillary Services  

Science Conference Proceedings (OSTI)

Many demand response resources are technically capable of providing ancillary services. In some cases, they can provide superior response to generators, as the curtailment of load is typically much faster than ramping thermal and hydropower plants. Analysis and quantification of demand response resources providing ancillary services is necessary to understand the resources economic value and impact on the power system. Methodologies used to study grid integration of variable generation can be adapted to the study of demand response. In the present work, we describe and illustrate a methodology to construct detailed temporal and spatial representations of the demand response resource and to examine how to incorporate those resources into power system models. In addition, the paper outlines ways to evaluate barriers to implementation. We demonstrate how the combination of these three analyses can be used to translate the technical potential for demand response providing ancillary services into a realizable potential.

Alkadi, Nasr E [ORNL; Starke, Michael R [ORNL

2013-01-01T23:59:59.000Z

292

Radioactive air emissions notice of construction fuel removal for 105-KW Basin  

Science Conference Proceedings (OSTI)

This document serves as a Notice of Construction (NOC), pursuant to the requirements of Washington Administrative Code (WAC) 246-247-060, and as a request for approval to construct, pursuant to 40 Code of Federal Regulations (CFR) 61.96, for the modifications, installation of new equipment, and fuel removal and sludge relocation activities at 105-KW Basin. The purpose of the activities described in this NOC is to enable the eventual retrieval and transport of the fuel for processing. The fuel retrieval and transport will require an integrated water treatment system for which performance specifications have been developed. These specifications are currently in the procurement process. Following procurement (and before installation of this system and the handling of fuel) design details will be provided to Washington State Department of Health (WDOH). The 105-K West Reactor (105-KW) and its associated spent nuclear fuel (SNF) storage basin were constructed in the early 1950s and are located on the Hanford Site in the 100-K Area about 1,400 feet from the Columbia River. The 105-KW Basin contains 964 Metric Tons of SNF stored under water in approximately 3,800 closed canisters. This SNF has been stored for varying periods of time ranging from 8 to 17 years. The 105-KW Basin is constructed of concrete with an epoxy coating and contains approximately 1.3 million gallons of water with an asphaltic membrane beneath the pool. Although the 105-KW Basin has not been known to leak, the discharge chute and associated construction joint have been isolated from the rest of the basin by metal isolation barriers. This was a precautionary measure, to mitigate the consequences of a seismic event. The proposed modifications described are scheduled to begin in calendar year 1997.

Hays, C.B.

1997-05-29T23:59:59.000Z

293

The Influence of Residential Solar Water Heating on Electric Utility Demand  

E-Print Network (OSTI)

Similar sets of residences in Austin, Texas with electric water heaters and solar water heaters with electric back-up were monitored during 1982 to determine their instantaneous electric demands, the purpose being to determine the influence of residential solar water heating on electric utility demand. The electric demand of solar water hears was found to be approximately 0.39 kW lass than conventional electric water heaters during the late late afternoon, early evening period in the summer months when the Austin utility experiences its peak demand. The annual load factor would be only very slightly reduced if there were a major penetration of solar water heaters in the all electric housing sector. Thus solar water heating represents beneficial load management for utilities experiencing summer peaks.

Vliet, G. C.; Askey, J. L.

1984-01-01T23:59:59.000Z

294

Scoping Study for Demand Respose DFT II Project in Morgantown, WV  

Science Conference Proceedings (OSTI)

This scoping study describes the underlying data resources and an analysis tool for a demand response assessment specifically tailored toward the needs of the Modern Grid Initiatives Demonstration Field Test in Phase II in Morgantown, WV. To develop demand response strategies as part of more general distribution automation, automated islanding and feeder reconfiguration schemes, an assessment of the demand response resource potential is required. This report provides the data for the resource assessment for residential customers and describes a tool that allows the analyst to estimate demand response in kW for each hour of the day, by end-use, season, day type (weekday versus weekend) with specific saturation rates of residential appliances valid for the Morgantown, WV area.

Lu, Shuai; Kintner-Meyer, Michael CW

2008-06-06T23:59:59.000Z

295

Plug-in privacy for Smart Metering billing  

E-Print Network (OSTI)

Smart Metering is a concept that allows to collect fine-grained consumption profiles from customers by replacing traditional electricity meters with Smart Meters in customers' households. The recorded consumption profile is the basis for the calculation of time-dependent tariffs but also allows deduction of the inhabitant's personal schedules and habits. The current reporting of such consumption profiles only protects this data from 3rd parties but falls short to protect the customer's privacy from illegitimate abuse by the supplier itself. We propose a privacy-preserving profile reporting protocol that enables billing for time-dependent tariffs without disclosing the actual data of the consumption profile to the supplier. Our approach relies on a zero-knowledge proof based on Pedersen Commitments performed by a plug-in privacy component that is put into the communication link between Smart Meter and supplier's back-end systems and requires no change to Smart Meter hardware and only little change to the softw...

Jawurek, Marek; Kerschbaum, Florian

2010-01-01T23:59:59.000Z

296

Influence of Air Conditioner Operation on Electricity Use and Peak Demand  

E-Print Network (OSTI)

Electricity demand due to occupant controlled room air conditioners in a large mater-metered apartment building is analyzed. Hourly data on the electric demand of the building and of individual air conditioners are used in analyses of annual and time-of-day peaks. Effects of occupant schedules and behavior are examined. We conclude that room air conditioners cause a sharp annual peak demand because occupants have strongly varying thresholds with respect to toleration of high indoor temperatures. However, time-or-day peaking is smoothed by air conditioning in this building due to significant off-peak operation of air conditioners by some occupants. If occupants were billed directly for electricity, off-peak use would probably diminish making the peaks more pronounced and exacerbating the utility company's load management problems. Future studies of this type in individually metered apartment buildings are recommended.

McGarity, A. E.; Feuermann, D.; Kempton, W.; Norford, L. K.

1987-01-01T23:59:59.000Z

297

Strategies for Demand Response in Commercial Buildings  

E-Print Network (OSTI)

the average and maximum peak demand savings. The electricity1: Average and Maximum Peak Electric Demand Savings during

Watson, David S.; Kiliccote, Sila; Motegi, Naoya; Piette, Mary Ann

2006-01-01T23:59:59.000Z

298

Demand Response Opportunities in Industrial Refrigerated Warehouses...  

NLE Websites -- All DOE Office Websites (Extended Search)

Demand Response Opportunities in Industrial Refrigerated Warehouses in California Title Demand Response Opportunities in Industrial Refrigerated Warehouses in California...

299

Opportunities for Energy Efficiency and Automated Demand Response in Industrial Refrigerated Warehouses in California  

Science Conference Proceedings (OSTI)

This report summarizes the Lawrence Berkeley National Laboratory's research to date in characterizing energy efficiency and open automated demand response opportunities for industrial refrigerated warehouses in California. The report describes refrigerated warehouses characteristics, energy use and demand, and control systems. It also discusses energy efficiency and open automated demand response opportunities and provides analysis results from three demand response studies. In addition, several energy efficiency, load management, and demand response case studies are provided for refrigerated warehouses. This study shows that refrigerated warehouses can be excellent candidates for open automated demand response and that facilities which have implemented energy efficiency measures and have centralized control systems are well-suited to shift or shed electrical loads in response to financial incentives, utility bill savings, and/or opportunities to enhance reliability of service. Control technologies installed for energy efficiency and load management purposes can often be adapted for open automated demand response (OpenADR) at little additional cost. These improved controls may prepare facilities to be more receptive to OpenADR due to both increased confidence in the opportunities for controlling energy cost/use and access to the real-time data.

Lekov, Alex; Thompson, Lisa; McKane, Aimee; Rockoff, Alexandra; Piette, Mary Ann

2009-05-11T23:59:59.000Z

300

Demand and Price Uncertainty: Rational Habits in International Gasoline Demand  

E-Print Network (OSTI)

Model of the Global Crude Oil Market and the U.S. RetailNoureddine. 2002. World crude oil and natural gas: a demandanalysis of the demand for oil in the Middle East. Energy

Scott, K. Rebecca

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "kw billing demand" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Demand and Price Volatility: Rational Habits in International Gasoline Demand  

E-Print Network (OSTI)

A Joint Model of the Global Crude Oil Market and the U.S.Noureddine. 2002. World crude oil and natural gas: a demandelasticity of demand for crude oil, not gasoline. Results

Scott, K. Rebecca

2011-01-01T23:59:59.000Z

302

Demand and Price Uncertainty: Rational Habits in International Gasoline Demand  

E-Print Network (OSTI)

A Joint Model of the Global Crude Oil Market and the U.S.Noureddine. 2002. World crude oil and natural gas: a demandelasticity of demand for crude oil, not gasoline. Results

Scott, K. Rebecca

2013-01-01T23:59:59.000Z

303

Demand and Price Uncertainty: Rational Habits in International Gasoline Demand  

E-Print Network (OSTI)

global gasoline and diesel price and income elasticities.shift in the short-run price elasticity of gasoline demand.Habits and Uncertain Relative Prices: Simulating Petrol Con-

Scott, K. Rebecca

2013-01-01T23:59:59.000Z

304

Cost Avoidance vs. Utility Bill Accounting - Explaining theDiscrepancy Between Guaranteed Savings in ESPC Projects and UtilityBills  

SciTech Connect

Federal agencies often ask if Energy Savings PerformanceContracts (ESPCs) result in the energy and cost savings projected duringthe project development phase. After investing in ESPCs, federal agenciesexpect a reduction in the total energy use and energy cost at the agencylevel. Such questions about the program are common when implementing anESPC project. But is this a fair or accurate perception? Moreimportantly, should the federal agencies evaluate the success or failureof ESPCs by comparing the utility costs before and after projectimplementation?In fact, ESPC contracts employ measurement andverification (M&V) protocols to measure and ensure kilowatt-hour orBTU savings at the project level. In most cases, the translation toenergy cost savings is not based on actual utility rate structure, but acontracted utility rate that takes the existing utility rate at the timethe contract is signed with a clause to escalate the utility rate by afixed percentage for the duration of the contract. Reporting mechanisms,which advertise these savings in dollars, may imply an impact to budgetsat a much higher level depending on actual utility rate structure. FEMPhas prepared the following analysis to explain why the utility billreduction may not materialize, demonstrate its larger implication onagency s energy reduction goals, and advocate setting the rightexpectations at the outset to preempt the often asked question why I amnot seeing the savings in my utility bill?

Kumar, S.; Sartor, D.

2005-08-15T23:59:59.000Z

305

SoCalGas - Non-Residential On-Bill Financing Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

On-Bill Financing Program On-Bill Financing Program SoCalGas - Non-Residential On-Bill Financing Program < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Multi-Family Residential Nonprofit Schools State Government Tribal Government Savings Category Other Program Info State California Program Type Utility Loan Program Rebate Amount General Minimum Loan Amount: $5,000/meter minimum Non-Institutional Customers: up to $100,000/meter with 5 year max payback Taxpayer Funded Institutions: up to $250,000/meter with 10 year max payback State of California: up to $1,000,000 with 10 year max payback Provider Southern California Gas Company The SoCalGas On-Bill Financing (OBF) program offers qualified business customers 0% financing from $5,000 to $100,000 per meter for qualifying

306

Planning Bill Nye The Science Guy's Climate Research Lab at Chabot Space  

NLE Websites -- All DOE Office Websites (Extended Search)

Planning Bill Nye The Science Guy's Climate Research Lab at Chabot Space Planning Bill Nye The Science Guy's Climate Research Lab at Chabot Space and Science Center Speaker(s): Andrew Anway David Bloom Date: September 24, 2008 - 12:00pm Location: 90-3075 Seminar Host/Point of Contact: Allan Chen Sometime in 2009, the Chabot Space and Science Center hopes to debut a new museum exhibition tentatively titled Bill Nye The Science Guy's Climate Research Lab, subtitle, Mission Possible: Reduce the CO2. The interactive show is anchored by science educator Bill Nye the Science Guy, is aimed towards children and families. It will explain the basic science behind climate change, and its potential effects on humans and the rest of the biosphere, while exploring some ways of reducing greenhouse gas emissions, both what we can do now, and advanced technologies that may someday play a

307

VIDEO: Bill Gates and Secretary Chu Chat on the Future of Energy |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

VIDEO: Bill Gates and Secretary Chu Chat on the Future of Energy VIDEO: Bill Gates and Secretary Chu Chat on the Future of Energy VIDEO: Bill Gates and Secretary Chu Chat on the Future of Energy March 5, 2012 - 1:24pm Addthis Secretary Chu sits down with Microsoft Founder and Chairman Bill Gates at the 2012 ARPA-E Energy Innovation Summit. April Saylor April Saylor Former Digital Outreach Strategist, Office of Public Affairs Last week, attendees at the 2012 ARPA-E Energy Innovation Summit heard from a variety of leaders from across the research, business and government sectors who spoke at the conference of nearly 2,400. These speakers, along with the startup companies and innovators in attendance, converged outside of Washington, D.C., to offer their take on how America can tackle our energy challenges. One of the top-level highlights from the Summit included this fireside chat

308

Iowa Shade Trees Bring Energy Bills Down, Beauty Up | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Shade Trees Bring Energy Bills Down, Beauty Up Shade Trees Bring Energy Bills Down, Beauty Up Iowa Shade Trees Bring Energy Bills Down, Beauty Up November 10, 2010 - 9:00am Addthis Volunteers from the Waverly Trees Forever group are planting windbreak trees on the north side of the mobile home court. Waverly experienced record flooding in 2008. | Photo Courtesy of Trees Forever Volunteers from the Waverly Trees Forever group are planting windbreak trees on the north side of the mobile home court. Waverly experienced record flooding in 2008. | Photo Courtesy of Trees Forever Lindsay Gsell What are the key facts? Iowa non-profit will plant 2,500 trees to encourage energy efficiency Using nearly $160,000 in State Energy Program funding through the Recovery Act Large shade trees can lower cooling bills by up to 30 percent

309

Iowa Shade Trees Bring Energy Bills Down, Beauty Up | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Iowa Shade Trees Bring Energy Bills Down, Beauty Up Iowa Shade Trees Bring Energy Bills Down, Beauty Up Iowa Shade Trees Bring Energy Bills Down, Beauty Up November 10, 2010 - 9:00am Addthis Volunteers from the Waverly Trees Forever group are planting windbreak trees on the north side of the mobile home court. Waverly experienced record flooding in 2008. | Photo Courtesy of Trees Forever Volunteers from the Waverly Trees Forever group are planting windbreak trees on the north side of the mobile home court. Waverly experienced record flooding in 2008. | Photo Courtesy of Trees Forever Lindsay Gsell What are the key facts? Iowa non-profit will plant 2,500 trees to encourage energy efficiency Using nearly $160,000 in State Energy Program funding through the Recovery Act Large shade trees can lower cooling bills by up to 30 percent

310

ARPA-E Announces 2012 Energy Innovation Summit Featuring Bill Gates, Fred  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Announces 2012 Energy Innovation Summit Featuring Bill Announces 2012 Energy Innovation Summit Featuring Bill Gates, Fred Smith and Lee Scott ARPA-E Announces 2012 Energy Innovation Summit Featuring Bill Gates, Fred Smith and Lee Scott September 9, 2011 - 9:25am Addthis New York, NY - The U.S. Department of Energy's Advanced Research Projects Agency - Energy (ARPA-E) Director, Arun Majumdar, announced yesterday that the Agency will hold its third annual ARPA-E Energy Innovation Summit from February 27 - 29, 2012 at the Gaylord Convention Center just outside Washington, D.C. Bill Gates, founder and chairman of Microsoft; Fred Smith, chairman, president and CEO of FedEx; and Lee Scott, former CEO of Wal-Mart; will join Secretary Chu and Director Majumdar as distinguished keynote speakers. "After two successful Summits, I'm excited to once again bring some of

311

Average U.S. residential summer 2013 electric bill expected to be ...  

U.S. Energy Information Administration (EIA)

The average U.S. household electric bill for June through August is expected to total $395, down 2.5% from last summer and the cheapest in four years.

312

SDG&E- Non-Residential On-Bill Financing Program  

Energy.gov (U.S. Department of Energy (DOE))

The SDG&E On-Bill Financing (OBF) program offers qualified business customers 0% financing from $5,000 to $100,000 per meter for qualifying natural gas equipment. All institutional customers...

313

SCE - Non-Residential On-Bill Financing Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

On-Bill Financing Program On-Bill Financing Program SCE - Non-Residential On-Bill Financing Program < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Multi-Family Residential Nonprofit Schools State Government Tribal Government Savings Category Other Maximum Rebate Taxpayer Funded Institutions: up to $250,000/meter with 5 year max payback Non-Institutional Customers: up to $100,000/meter with 5 year max payback State of California: up to $1,000,000 with 10 year max payback Program Info Start Date 8/2/2010 State California Program Type Utility Loan Program Rebate Amount 5,000 minimum Provider Business Programs The SoCalGas On-Bill Financing (OBF) program offers qualified business customers 0% financing from $5,000 to $100,000 per meter for qualifying

314

New Jersey Natural Gas - SAVEGREEN On-Bill Financing Program | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

New Jersey Natural Gas - SAVEGREEN On-Bill Financing Program New Jersey Natural Gas - SAVEGREEN On-Bill Financing Program New Jersey Natural Gas - SAVEGREEN On-Bill Financing Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Construction Commercial Weatherization Design & Remodeling Other Sealing Your Home Ventilation Maximum Rebate $10,000 Program Info State New Jersey Program Type Utility Loan Program Rebate Amount $2,500-$10,000 Provider New Jersey Natural Gas Through the SAVEGREEN Project, New Jersey Natural Gas (NJNG) provides an On-Bill Repayment Program. Qualified customers can borrow $2,500-$10,000 at 0% APR fixed rate for 10 years with no fees, points or closing costs. A variety of equipment and measures may qualify for financing under this

315

The Impact of Rate Design and Net Metering on the Bill Savings from  

Open Energy Info (EERE)

Impact of Rate Design and Net Metering on the Bill Savings from Impact of Rate Design and Net Metering on the Bill Savings from Distributed Photovoltaics (PV) for Residential Customers in California Jump to: navigation, search Tool Summary LAUNCH TOOL Name: The Impact of Rate Design and Net Metering on the Bill Savings from Distributed Photovoltaics (PV) for Residential Customers in California Focus Area: Renewable Energy Topics: Best Practices Website: eetd.lbl.gov/ea/emp/reports/lbnl-3276e.pdf Equivalent URI: cleanenergysolutions.org/content/impact-rate-design-and-net-metering-b Language: English Policies: Deployment Programs DeploymentPrograms: Demonstration & Implementation This report analyzes the bill savings from photovoltaic (PV) deployment for residential customers of California's two largest electric utilities -

316

Effects of the drought on California electricity supply and demand  

E-Print Network (OSTI)

Acknowledgments SUMMARY Electricity Demand ElectricityAdverse Impacts ELECTRICITY DEMAND . . . .Demand forElectricity Sales Electricity Demand by Major Utility

Benenson, P.

2010-01-01T23:59:59.000Z

317

building demand | OpenEI  

Open Energy Info (EERE)

demand demand Dataset Summary Description This dataset contains hourly load profile data for 16 commercial building types (based off the DOE commercial reference building models) and residential buildings (based off the Building America House Simulation Protocols). This dataset also includes the Residential Energy Consumption Survey (RECS) for statistical references of building types by location. Source Commercial and Residential Reference Building Models Date Released April 18th, 2013 (9 months ago) Date Updated July 02nd, 2013 (7 months ago) Keywords building building demand building load Commercial data demand Energy Consumption energy data hourly kWh load profiles Residential Data Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Annually

318

Demand Response Research in Spain  

NLE Websites -- All DOE Office Websites (Extended Search)

Demand Response Research in Spain Demand Response Research in Spain Speaker(s): Iñigo Cobelo Date: August 22, 2007 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Mary Ann Piette The Spanish power system is becoming increasingly difficult to operate. The peak load grows every year, and the permission to build new transmission and distribution infrastructures is difficult to obtain. In this scenario Demand Response can play an important role, and become a resource that could help network operators. The present deployment of demand response measures is small, but this situation however may change in the short term. The two main Spanish utilities and the transmission network operator are designing research projects in this field. All customer segments are targeted, and the research will lead to pilot installations and tests.

319

EIA - AEO2010 - Electricity Demand  

Gasoline and Diesel Fuel Update (EIA)

Electricity Demand Electricity Demand Annual Energy Outlook 2010 with Projections to 2035 Electricity Demand Figure 69. U.S. electricity demand growth 1950-2035 Click to enlarge » Figure source and data excel logo Figure 60. Average annual U.S. retail electricity prices in three cases, 1970-2035 Click to enlarge » Figure source and data excel logo Figure 61. Electricity generation by fuel in three cases, 2008 and 2035 Click to enlarge » Figure source and data excel logo Figure 62. Electricity generation capacity additions by fuel type, 2008-2035 Click to enlarge » Figure source and data excel logo Figure 63. Levelized electricity costs for new power plants, 2020 and 2035 Click to enlarge » Figure source and data excel logo Figure 64. Electricity generating capacity at U.S. nuclear power plants in three cases, 2008, 2020, and 2035

320

Winter Demand Impacted by Weather  

Gasoline and Diesel Fuel Update (EIA)

8 Notes: Heating oil demand is strongly influenced by weather. The "normal" numbers are the expected values for winter 2000-2001 used in EIA's Short-Term Energy Outlook. The chart...

Note: This page contains sample records for the topic "kw billing demand" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Demand for money in China .  

E-Print Network (OSTI)

??This research investigates the long-run equilibrium relationship between money demand and its determinants in China over the period 1952-2004 for three definitions of money –… (more)

Zhang, Qing

2006-01-01T23:59:59.000Z

322

Thermal Mass and Demand Response  

NLE Websites -- All DOE Office Websites (Extended Search)

Thermal Mass and Demand Response Speaker(s): Gregor Henze Phil C. Bomrad Date: November 2, 2011 - 12:00pm Location: 90-4133 Seminar HostPoint of Contact: Janie Page The topic of...

323

Automated Demand Response and Commissioning  

E-Print Network (OSTI)

Conference on Building Commissioning: May 4-6, 2005 Motegi,National Conference on Building Commissioning: May 4-6, 2005Demand Response and Commissioning Mary Ann Piette, David S.

Piette, Mary Ann; Watson, David S.; Motegi, Naoya; Bourassa, Norman

2005-01-01T23:59:59.000Z

324

Distillate Demand Strong Last Winter  

Gasoline and Diesel Fuel Update (EIA)

4 Notes: Well, distillate fuel demand wasn't the reason that stocks increased in January 2001 and kept prices from going higher. As you will hear shortly, natural gas prices spiked...

325

Leslie Mancebo (7234) Transportation Demand &  

E-Print Network (OSTI)

Leslie Mancebo (7234) Transportation Demand & Marketing Coordinator 1 FTE, 1 HC Administrative Vice Chancellor Transportation and Parking Services Clifford A. Contreras (0245) Director 30.10 FTE Alternative Transportation & Marketing Reconciliation Lourdes Lupercio (4723) Michelle McArdle (7512) Parking

Hammock, Bruce D.

326

STEO December 2012 - coal demand  

U.S. Energy Information Administration (EIA) Indexed Site

coal demand seen below 1 billion tons in 2012 for fourth year in a row Coal consumption by U.S. power plants to generate electricity is expected to fall below 1 billion tons in...

327

Retail Demand Response in Southwest Power Pool  

SciTech Connect

In 2007, the Southwest Power Pool (SPP) formed the Customer Response Task Force (CRTF) to identify barriers to deploying demand response (DR) resources in wholesale markets and develop policies to overcome these barriers. One of the initiatives of this Task Force was to develop more detailed information on existing retail DR programs and dynamic pricing tariffs, program rules, and utility operating practices. This report describes the results of a comprehensive survey conducted by LBNL in support of the Customer Response Task Force and discusses policy implications for integrating legacy retail DR programs and dynamic pricing tariffs into wholesale markets in the SPP region. LBNL conducted a detailed survey of existing DR programs and dynamic pricing tariffs administered by SPP's member utilities. Survey respondents were asked to provide information on advance notice requirements to customers, operational triggers used to call events (e.g. system emergencies, market conditions, local emergencies), use of these DR resources to meet planning reserves requirements, DR resource availability (e.g. seasonal, annual), participant incentive structures, and monitoring and verification (M&V) protocols. Nearly all of the 30 load-serving entities in SPP responded to the survey. Of this group, fourteen SPP member utilities administer 36 DR programs, five dynamic pricing tariffs, and six voluntary customer response initiatives. These existing DR programs and dynamic pricing tariffs have a peak demand reduction potential of 1,552 MW. Other major findings of this study are: o About 81percent of available DR is from interruptible rate tariffs offered to large commercial and industrial customers, while direct load control (DLC) programs account for ~;;14percent. o Arkansas accounts for ~;;50percent of the DR resources in the SPP footprint; these DR resources are primarily managed by cooperatives. o Publicly-owned cooperatives accounted for 54percent of the existing DR resources among SPP members. For these entities, investment in DR is often driven by the need to reduce summer peak demand that is used to set demand charges for each distribution cooperative. o About 65-70percent of the interruptible/curtailable tariffs and DLC programs are routinely triggered based on market conditions, not just for system emergencies. Approximately, 53percent of the DR resources are available with less than two hours advance notice and 447 MW can be dispatched with less than thirty minutes notice. o Most legacy DR programs offered a reservation payment ($/kW) for participation; incentive payment levels ranged from $0.40 to $8.30/kW-month for interruptible rate tariffs and $0.30 to $4.60/kW-month for DLC programs. A few interruptible programs offered incentive payments which were explicitly linkedto actual load reductions during events; payments ranged from 2 to 40 cents/kWh for load curtailed.

Bharvirkar, Ranjit; Heffner, Grayson; Goldman, Charles

2009-01-30T23:59:59.000Z

328

Data:0474a1ed-7103-4b41-be83-884373cac645 | Open Energy Information  

Open Energy Info (EERE)

ed-7103-4b41-be83-884373cac645 ed-7103-4b41-be83-884373cac645 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Douglas, Georgia (Utility Company) Effective date: 2012/01/01 End date if known: Rate name: Medium Power Sector: Industrial Description: Current month kW + prior 11 months kW >30kW & < 500 kW. Source or reference: Rate Binder Kelly 2 ISU Documentation Source Parent: Comments Minimum monthly bill: $50 + ($8.00 * Billing kW in excess of 30kW) + PCA & ECCR & Tax Applicability Demand (kW) Minimum (kW): Maximum (kW): History (months): Energy (kWh) Minimum (kWh):

329

Data:Dbd5050f-f9c5-4299-ac8a-84c8c9c7588c | Open Energy Information  

Open Energy Info (EERE)

Energy Billing Sector: Industrial Description: For any customer with average monthly energy demand during the most recent 12 months of 50 kW or more. Includes service at one...

330

Browse wiki | Open Energy Information  

Open Energy Info (EERE)

customer t ... AVAILABILITY Available for any customer taking service directly from substation and having Billing Demand of over 10,000 kW. Applicant must agree to a five (5) year...

331

Demand Response Spinning Reserve Demonstration  

Science Conference Proceedings (OSTI)

The Demand Response Spinning Reserve project is a pioneeringdemonstration of how existing utility load-management assets can providean important electricity system reliability resource known as spinningreserve. Using aggregated demand-side resources to provide spinningreserve will give grid operators at the California Independent SystemOperator (CAISO) and Southern California Edison (SCE) a powerful, newtool to improve system reliability, prevent rolling blackouts, and lowersystem operating costs.

Eto, Joseph H.; Nelson-Hoffman, Janine; Torres, Carlos; Hirth,Scott; Yinger, Bob; Kueck, John; Kirby, Brendan; Bernier, Clark; Wright,Roger; Barat, A.; Watson, David S.

2007-05-01T23:59:59.000Z

332

Seeing Savings from an ESPC Project in Fort Polk's Utility Bills  

SciTech Connect

Federal agencies have implemented many energy efficiency projects over the years with direct funding or alternative financing vehicles such as energy savings performance contracts (ESPCs). While it is generally accepted that these projects save energy and costs, the savings are usually not obvious in the utility bills. This is true for many valid technical reasons, even when savings are verified in other ways to the highest degree of certainty. However, any perceived deficiency in the evidence for savings is problematic when auditors or other observers evaluate the outcome of energy projects and the achievements of energy management programs. This report discusses under what circumstances energy savings should or should not be evident in utility bills. In the special case of a large ESPC project at the Army's Fort Polk, the analysis of utility bills carried out by the authors does unequivocally confirm and quantify savings. The data requirements and methods for arriving at definitive answers through utility bill analysis are demonstrated in our discussion of the Fort Polk project. The following paragraphs address why the government generally should not expect to see savings from ESPC projects in their utility bills. We also review lessons learned and best practices for measurement and verification (M&V) that can assure best value for the government and are more practical, straightforward, and cost-effective than utility bill analysis.

Shonder, J.A.

2005-03-08T23:59:59.000Z

333

MHK Projects/Evopod E35 35kW grid connected demonstrator | Open Energy  

Open Energy Info (EERE)

E35 35kW grid connected demonstrator E35 35kW grid connected demonstrator < MHK Projects Jump to: navigation, search << Return to the MHK database homepage Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":5,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"500px","height":"350px","centre":false,"title":"","label":"","icon":"File:Aquamarine-marker.png","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":55.3028,"lon":-5.59772,"alt":0,"address":"","icon":"http:\/\/prod-http-80-800498448.us-east-1.elb.amazonaws.com\/w\/images\/7\/74\/Aquamarine-marker.png","group":"","inlineLabel":"","visitedicon":""}]}

334

200 kW, 800 MHz transmitter system for lower hybrid heating  

SciTech Connect

This paper describes a new rf heating system which has just been completed and is now operational on the ATC machine. The system utilizes four UHF TV klystrons to generate at least 200 kW of power at a frequency of 800 MHz. Pulse widths can be varied from 20 $mu$sec up to 20 msec. A radar type floating deck modulator along with photo-optical transmitting and receiving devices have been incorporated into the system to provide the pulse fidelity and versatility which characterizes this equipment. Modular construction was emphasized in the design, when possible, to reduce maintenance and down time in the advent of component falilure. Hybrid combining techniques are utilized in order to provide two 100 kW feeds into the machine. (auth)

Deitz, A.

1975-01-01T23:59:59.000Z

335

United Technologies Research Center 8-kW prototype wind system. Final test report  

DOE Green Energy (OSTI)

The United Technologies Research Center 8 kW prototype wind system underwent testing at the Rocky Flats Small Wind Systems Test Center from April 1980 through August 1980. During atmospheric testing, the machine survived wind speeds of 30.8 m/s (69 mph) without incurring damage and proved it was capable of meeting the design specification for power production (8 kW at 9 m/s - 20 mph). Erratic cycling of the generator speed detector was the only operational problem encountered. Vibration tests indicated the first and second bending modes of the tower were excited during actual machine operation, but modifications were not required. Noise measurements revealed that sound pressure levels of the UTRC are within an acceptable range and should pose no barriers to machine use.

Higashi, K. K.

1981-09-01T23:59:59.000Z

336

Enertech 15-kW wind-system development. Phase II. Fabrication and test  

DOE Green Energy (OSTI)

This Phase II report presents a description of the Enertech 15 kW prototype wind system hardware fabrication; results of component tests; and results of preliminary testing conducted at Norwich, VT and the RF Wind Energy Research Center. In addition, the assembly sequence is documented. During testing, the unit experienced several operational problems, but testing proved the design concept and demonstrated the system's ability to meet the contract design specifications for power output.

Zickefoose, C.R.

1982-12-01T23:59:59.000Z

337

Field Evaluation of the 200 kW PAFC Unit at the Pittsburgh International Airport  

Science Conference Proceedings (OSTI)

Distributed generation, particularly in combination with the benefits of fuel cells, is attracting increasing utility industry interest. This report details more than 20,000 hours of automatic, unattended operation of an ONSI 200 kW phosphoric acid fuel cell at the Pittsburgh International Airport. Also included are installation, operation, and performance data on more than twenty other units in the U.S. ONSI fleet.

1997-09-30T23:59:59.000Z

338

50 kW PEM Fuel Cell System Design, Fabrication, and Test: System Design -- Final Report  

Science Conference Proceedings (OSTI)

This final report describes the results of a development program funded jointly by the U.S. Department of Energy, Arthur D. Little, and EPRIsolutions. The effort was aimed at the conceptual design and optimization of a 50 kW commercial power system, using advanced proton exchange (or polymer electrolyte) membrane fuel cell (PEMFC) technology and the verification of key design parameters. (Note: This design effort addresses some of the key technical issues faced by the developers of commercial-scale PEMFC...

2000-12-11T23:59:59.000Z

339

Performance of 350kW photovoltaic power system for Saudi Arabian villages after 30 months  

Science Conference Proceedings (OSTI)

The installation and checkout of the 350kW PV system was completed in September 1981. Since then this system has operated satisfactorily over the past two and half years and has experienced very little downtime. The system has a rather unique capability to operate in standalone or any of several cogeneration modes. This paper presents an update of the system performance with emphasis on the photovoltaic field. Research effort being implemented for the next two years are also briefly summarized.

Koshaim, B.; Al-Sani, A.; Huraib, F.; Imamura, M.S.; Salim, A.

1984-05-01T23:59:59.000Z

340

Distributed Generation Study/615 kW Waukesha Packaged System | Open Energy  

Open Energy Info (EERE)

kW Waukesha Packaged System kW Waukesha Packaged System < Distributed Generation Study Jump to: navigation, search Study Location Des Plaines, Illinois Site Description Testing Laboratory Study Type Laboratory Test Technology Internal Combustion Engine Prime Mover Waukesha VGF 36GLD Heat Recovery Systems Sondex PHE-Type SL140-TM-EE-190, Sondex PHE-Type SL140-TM-EE-150, Cain UTR1-810A17.5SSP Fuel Natural Gas System Installer GTI System Enclosure Outdoor System Application Combined Heat and Power Number of Prime Movers 1 Stand-alone Capability None Power Rating 615 kW0.615 MW 615,000 W 615,000,000 mW 6.15e-4 GW 6.15e-7 TW Nominal Voltage (V) 480 Heat Recovery Rating (BTU/hr) 2500000 Cooling Capacity (Refrig/Tons) 90 Origin of Controller 3rd Party Off-the-Shelf Component Integration Factory Integrated

Note: This page contains sample records for the topic "kw billing demand" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

National Action Plan on Demand Response  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Action Plan on Demand National Action Plan on Demand Action Plan on Demand National Action Plan on Demand Response Response Federal Utilities Partnership Working Group Federal Utilities Partnership Working Group November 18, 2008 November 18, 2008 Daniel Gore Daniel Gore Office of Energy Market Regulation Office of Energy Market Regulation Federal Energy Regulatory Commission Federal Energy Regulatory Commission The author's views do not necessarily represent the views of the Federal Energy Regulatory Commission Presentation Contents Presentation Contents Statutory Requirements Statutory Requirements National Assessment [Study] of Demand Response National Assessment [Study] of Demand Response National Action Plan on Demand Response National Action Plan on Demand Response General Discussion on Demand Response and Energy Outlook

342

100kW Energy Transfer Multiplexer Power Converter Prototype Development Project  

DOE Green Energy (OSTI)

Project Final Report for "100kW Energy Transfer Multiplexer Power Converter Prototype Development Project" prepared under DOE grant number DE-FG36-03GO13138. This project relates to the further development and prototype construction/evaluation for the Energy Transfer Multiplexer (ETM) power converter topology concept. The ETM uses a series resonant link to transfer energy from any phase of a multiphase input to any phase of a multiphase output, converting any input voltage and frequency to any output voltage and frequency. The basic form of the ETM converter consists of an eight (8)-switch matrix (six phase power switches and two ground power switches) and a series L-C resonant circuit. Electronic control of the switches allows energy to be transferred in the proper amount from any phase to any other phase. Depending upon the final circuit application, the switches may be either SCRs or IGBTs. The inherent characteristics of the ETM converter include the following: Power processing in either direction (bidirectional); Large voltage gain without the need of low frequency magnetics; High efficiency independent of output load and frequency; Wide bandwidth with fast transient response and; Operation as a current source. The ETM is able to synthesize true sinusoidal waveforms with low harmonic distortions. For a low power PM wind generation system, the ETM has the following characteristics and advantages: It provides voltage gain without the need of low frequency magnetics (DC inductors) and; It has constant high efficiency independent of the load. The ETM converter can be implemented into a PM wind power system with smaller size, reduced weight and lower cost. As a result of our analyses, the ETM offers wind power generation technology for the reduction of the cost and size as well as the increase in performance of low power, low wind speed power generation. This project is the further theoretical/analytical exploration of the ETM converter concept in relationship to PM wind power generator applications in the 100kW and under power range. The theoretical/analytical and bench scale work focuses on simplifying the basic ETM converter topology (in terms of parts count and complexity) for the specific application of the low power PM system. The project goals and objectives were for Spellman HV will develop a 100kW prototype ETM power converter based on paralleled lower ratings converters. The proposed configuration of this prototype is a 100kW rated converter comprised of four (4) 34kW rated modules connected in parallel (the fourth converter is included to demonstrate N+1 fault tolerance). This approach is more viable as there is lower technological risk involved in developing a 34kW-rated converter than a single 100kW unit. The modular system approach should have a lower deployment and service cost over a single unit system, because of the economics of scale (smaller units at a higher volume means lower manufacturing cost) and because of improved serviceability (a non-redundant power system with one failed module will still operate at a lower power level). There is also the added benefit that greater commercial application and acceptance should be achieved by having a modular system available in which fault tolerance (N+1 or 2N) is a feature. This modular approach would allow the output power to be increased by adding more paralleled converters. Thus, the maximum output power of the overall power system is a function of the interconnection medium (the hot swap connection subsystem), rather than the ratings of a single module. The project was implemented with Spellman HV acting as the program management and production assembly and test facility; The Baker Company acting as a technical consultant and resource when required; and dtm Associates acting as the design/development resource for the hardware development of the 100kW ETM converter prototype.

S. Merrill Skeist; Richard H. (Dick) Baker; Anthony G.P. Marini; DOE Project Officer - Keith Bennett

2006-03-21T23:59:59.000Z

343

Data:884813d3-7408-4343-a09d-297e3f8d5123 | Open Energy Information  

Open Energy Info (EERE)

3d3-7408-4343-a09d-297e3f8d5123 3d3-7408-4343-a09d-297e3f8d5123 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Rappahannock Electric Coop Effective date: 2009/11/01 End date if known: Rate name: LARGE POWER SERVICE SCHEDULE LP-1-RA V2 Sector: Industrial Description: APPLICABILITY Applicable to all Customers along the lines of the Cooperative contracting for a load of 100 kW or more. Demand Delivery Charges: First 100 kW of billing demand delivered @ $1.50 per kW Next 400 kW of billing demand delivered @ $1.25 per kW Next 1,500 kW of billing demand delivered @ $1.10 per kW Over 2,000 kW of billing demand delivered @ $1.00 per kW

344

Demand Response and Open Automated Demand Response Opportunities for Data Centers  

E-Print Network (OSTI)

Standardized Automated Demand Response Signals. Presented atand Automated Demand Response in Industrial RefrigeratedActions for Industrial Demand Response in California. LBNL-

Mares, K.C.

2010-01-01T23:59:59.000Z

345

Open Automated Demand Response Communications in Demand Response for Wholesale Ancillary Services  

E-Print Network (OSTI)

A. Barat, D. Watson. 2006 Demand Response Spinning ReserveKueck, and B. Kirby 2008. Demand Response Spinning ReserveReport 2009. Open Automated Demand Response Communications

Kiliccote, Sila

2010-01-01T23:59:59.000Z

346

Definition: Demand | Open Energy Information  

Open Energy Info (EERE)

form form View source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Definition Edit with form History Facebook icon Twitter icon » Definition: Demand Jump to: navigation, search Dictionary.png Demand The rate at which electric energy is delivered to or by a system or part of a system, generally expressed in kilowatts or megawatts, at a given instant or averaged over any designated interval of time., The rate at which energy is being used by the customer.[1] Related Terms energy, electricity generation References ↑ Glossary of Terms Used in Reliability Standards An i Like Like You like this.Sign Up to see what your friends like. nline Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Demand&oldid=480555"

347

Successful demand-side management  

Science Conference Proceedings (OSTI)

This article is a brief summary of a series of case studies of five publicly-owned utilities that are noted for their success with demand-side management. These utilities are: (1) city of Austin, Texas, (2) Burlington Electric Department in Vermont, (3) Sacramento Municipal Utility District in California, (4) Seattle City Light, and (5) Waverly Light and Power in Iowa. From these case studies, the authors identified a number of traits associated with a successful demand-side management program. These traits are: (1) high rates, (2) economic factors, (3) environmental awareness, (4) state emphasis on integrated resource planning/demand side management, (5) local political support, (6) large-sized utilities, and (7) presence of a champion.

Hadley, S. [Oak Ridge National Laboratory, TN (United States); Flanigan, T. [Results Center, Aspen, CO (United States)

1995-05-01T23:59:59.000Z

348

Winter Demand Impacted by Weather  

Gasoline and Diesel Fuel Update (EIA)

8 8 Notes: Heating oil demand is strongly influenced by weather. The "normal" numbers are the expected values for winter 2000-2001 used in EIA's Short-Term Energy Outlook. The chart indicates the extent to which the last winter exhibited below-normal heating degree-days (and thus below-normal heating demand). Temperatures were consistently warmer than normal throughout the 1999-2000 heating season. This was particularly true in November 1999, February 2001 and March 2001. For the heating season as a whole (October through March), the 1999-2000 winter yielded total HDDs 10.7% below normal. Normal temperatures this coming winter would, then, be expected to bring about 11% higher heating demand than we saw last year. Relative to normal, the 1999-2000 heating season was the warmest in

349

Turkey's energy demand and supply  

SciTech Connect

The aim of the present article is to investigate Turkey's energy demand and the contribution of domestic energy sources to energy consumption. Turkey, the 17th largest economy in the world, is an emerging country with a buoyant economy challenged by a growing demand for energy. Turkey's energy consumption has grown and will continue to grow along with its economy. Turkey's energy consumption is high, but its domestic primary energy sources are oil and natural gas reserves and their production is low. Total primary energy production met about 27% of the total primary energy demand in 2005. Oil has the biggest share in total primary energy consumption. Lignite has the biggest share in Turkey's primary energy production at 45%. Domestic production should be to be nearly doubled by 2010, mainly in coal (lignite), which, at present, accounts for almost half of the total energy production. The hydropower should also increase two-fold over the same period.

Balat, M. [Sila Science, Trabzon (Turkey)

2009-07-01T23:59:59.000Z

350

Demand Shifting With Thermal Mass in Large Commercial Buildings: Field Tests, Simulation and Audits  

E-Print Network (OSTI)

Tariff Summer monthly bill Electricity end-use breakdownTariff Summer monthly bill Electricity end-use breakdownTariff Summer monthly bill Electricity end-use breakdown

Xu, Peng; Haves, Philip; Piette, Mary Ann; Zagreus, Leah

2005-01-01T23:59:59.000Z

351

Unlocking the potential for efficiency and demand response through advanced metering  

E-Print Network (OSTI)

in any way to their electricity bill. Despite billions ofsave money on their electricity bill. Unfortunately, thisand bills is advanced metering infrastructure (AMI) that allows for the collection of hourly or sub-hourly electricity

Levy, Roger; Herter, Karen; Wilson, John

2004-01-01T23:59:59.000Z

352

California Energy Demand Scenario Projections to 2050  

E-Print Network (OSTI)

residential electricity consumption, the flattening of the demand curves (except Maximum demand) reflects decreasing population growth ratesresidential electricity demand are described in Table 11. For simplicity, end use-specific UEC and saturation rates

McCarthy, Ryan; Yang, Christopher; Ogden, Joan M.

2008-01-01T23:59:59.000Z

353

EIA projections of coal supply and demand  

SciTech Connect

Contents of this report include: EIA projections of coal supply and demand which covers forecasted coal supply and transportation, forecasted coal demand by consuming sector, and forecasted coal demand by the electric utility sector; and policy discussion.

Klein, D.E.

1989-10-23T23:59:59.000Z

354

Coordination of Energy Efficiency and Demand Response  

E-Print Network (OSTI)

percent of 2008 summer peak demand (FERC, 2008). Moreover,138,000 MW (14 percent of peak demand) by 2019 (FERC, 2009).non-coincident summer peak demand by 157 GW” by 2030, or 14–

Goldman, Charles

2010-01-01T23:59:59.000Z

355

Retail Demand Response in Southwest Power Pool  

E-Print Network (OSTI)

pricing tariffs have a peak demand reduction potential ofneed to reduce summer peak demand that is used to set demandcustomers and a system peak demand of over 43,000 MW. SPP’s

Bharvirkar, Ranjit

2009-01-01T23:59:59.000Z

356

Demand Responsive Lighting: A Scoping Study  

E-Print Network (OSTI)

with total Statewide peak demand and on peak days isto examine the electric peak demand related to lighting inDaily) - TOU Savings - Peak Demand Charges - Grid Peak -Low

Rubinstein, Francis; Kiliccote, Sila

2007-01-01T23:59:59.000Z

357

Tankless Demand Water Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Demand Water Heaters Tankless Demand Water Heaters August 19, 2013 - 2:57pm Addthis Illustration of an electric demand water heater. At the top of the image, the heating unit is...

358

CALIFORNIA ENERGY DEMAND 20122022 FINAL FORECAST  

E-Print Network (OSTI)

CALIFORNIA ENERGY DEMAND 20122022 FINAL FORECAST Volume 2: Electricity Demand.Oglesby Executive Director #12;i ACKNOWLEDGEMENTS The demand forecast is the combined product to the contributing authors listed previously, Mohsen Abrishami prepared the commercial sector forecast. Mehrzad

359

CALIFORNIA ENERGY DEMAND 20142024 FINAL FORECAST  

E-Print Network (OSTI)

CALIFORNIA ENERGY DEMAND 20142024 FINAL FORECAST Volume 2: Electricity Demand The demand forecast is the combined product of the hard work and expertise of numerous California Energy previously, Mohsen Abrishami prepared the commercial sector forecast. Mehrzad Soltani Nia helped prepare

360

CALIFORNIA ENERGY DEMAND 20142024 REVISED FORECAST  

E-Print Network (OSTI)

CALIFORNIA ENERGY DEMAND 20142024 REVISED FORECAST Volume 2: Electricity Demand Robert P. Oglesby Executive Director #12;i ACKNOWLEDGEMENTS The demand forecast is the combined prepared the commercial sector forecast. Mehrzad Soltani Nia helped prepare the industrial forecast

Note: This page contains sample records for the topic "kw billing demand" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Data:921a69a5-8b95-4272-9f70-5bd2c4fe058d | Open Energy Information  

Open Energy Info (EERE)

a69a5-8b95-4272-9f70-5bd2c4fe058d a69a5-8b95-4272-9f70-5bd2c4fe058d No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Greenwood Commissioners-Pub Wk Effective date: 2008/09/01 End date if known: Rate name: Municipal service - with Demand Sector: Industrial Description: MINIMUM CHARGE: The minimum monthly charge shall be the "Facility Charge". The following Tiered Demand Charge schedule is applied: First 30 kW of Billing Demand ................................... $1.890 Per kW. All Over 30 kW of Billing Demand ............................. $2.956 Per kW. DETERMINATION OF BILLING DEMAND: The "Billing Demand" for the billing period shall be the maximum integrated thirty minute demand recorded during the billing period for which the bill is rendered.

362

The Impact of Rate Design and Net Metering on the Bill Savings from  

NLE Websites -- All DOE Office Websites (Extended Search)

The Impact of Rate Design and Net Metering on the Bill Savings from The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California Title The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California Publication Type Report Refereed Designation Unknown Year of Publication 2010 Authors Darghouth, Naïm, Galen L. Barbose, and Ryan H. Wiser Pagination 62 Date Published 04/2010 Publisher LBNL City Berkeley Keywords electricity markets and policy group, electricity rate design, energy analysis and environmental impacts department, net metering, photovoltaics Abstract Net metering has become a widespread policy in the U.S. for supporting distributed photovoltaics (PV) adoption.1 Though specific design details vary, net metering allows customers with PV to reduce their electric bills by offsetting their consumption with PV generation, independent of the timing of the generation relative to consumption - in effect, compensating the PV generation at retail electricity rates (Rose et al. 2009). Though net metering has played an important role in jump-starting the PV market in the U.S., challenges to net metering policies have emerged in a number of states and contexts, and alternative compensation methods are under consideration. Moreover, one inherent feature of net metering is that the value of the utility bill savings it provides to customers with PV depends heavily on the structure of the underlying retail electricity rate, as well as on the characteristics of the customer and PV system. Consequently, the bill-savings value of net metering - and the impact of moving to alternative compensation mechanisms - can vary substantially from one customer to the next. For these reasons, it is important for policymakers and others that seek to support the development of distributed PV to understand both how the bill savings benefits of PV varies under net metering, and how the bill savings under net metering compares to savings associated with other possible compensation mechanisms. To advance this understanding, we analyze the bill savings from PV for residential customers of California's two largest electric utilities, Pacific Gas and Electric (PG&E) and Southern California Edison (SCE).3 The analysis is based on hourly load data from a sample of 215 residential customers located in the service territories of the two utilities, matched with simulated hourly PV production for the same time period based on data from the nearest of 73 weather stations in the state. We focus on these two utilities, both because we had ready access to a sample of load data for their residential customers, and because their service territories are the largest markets for residential PV in the country.

363

Long-billed curlews on the Yakima Training Center: Information for base realignment  

SciTech Connect

This report summarizes and discusses the results obtained during 1992 from the study of long-billed curlews on the Yakima Training Center (YTC), which Pacific Northwest Laboratory conducted for the US Department of the Army. This study was initiated to provide basic ecological information on YTC long-billed curlews (Numenius americanus). The long-billed curlew is a relatively common spring and summer resident on the YTC. However, other than casual observations, very little is known about the distribution, density, reproductive success, and habitat requirements for this species on the YTC. Until recently the long-billed curlew was a US Fish and Wildlife Service candidate for listing as threatened or endangered; however, on November 21, 1991 it was down-listed to Class IIIc. The Washington Department of Wildlife lists the long-billed curlew as a ``species of special concern.`` Specific objectives of this study were to (1) locate nesting areas, (2) locate brood-rearing areas, (3) evaluate habitat requirements, (4) determine diet, (5) evaluate response to troop activities, (6) evaluate the impact of livestock grazing, (7) estimate the population size, and (8) estimate recruitment rates. Six curlews (four females and two males) were captured and fitted with radio transmitters. These birds were relocated to obtain nesting, habitat use, and feeding information. Road surveys conducted over most of the YTC provided information on the bird`s general distribution, habitat requirements, and nesting and brood-rearing areas.

Hand, K.D.; Cadwell, L.L.; Eberhardt, L.E.

1994-02-01T23:59:59.000Z

364

Electric Utility Demand-Side Management 1997  

U.S. Energy Information Administration (EIA)

Electric Utility Demand-Side Management 1997 Executive Summary Background Demand-side management (DSM) programs consist of the planning, implementing, and monitoring ...

365

Equity Capital Flows and Demand for REITs  

Science Conference Proceedings (OSTI)

This paper examines the shape of the market demand curve for ... Our results do not support a downward demand curve for ... Charleston, IL 61920, USA e-mail: ...

366

Home Network Technologies and Automating Demand Response  

NLE Websites -- All DOE Office Websites (Extended Search)

electricity generation capacity to meet unrestrained future demand. To address peak electricity use Demand Response (DR) systems are being proposed to motivate reductions in...

367

Coordination of Energy Efficiency and Demand Response  

E-Print Network (OSTI)

California Long-term Energy Efficiency Strategic Plan. B-2 Coordination of Energy Efficiency and Demand Response> B-4 Coordination of Energy Efficiency and Demand Response

Goldman, Charles

2010-01-01T23:59:59.000Z

368

Installation and Commissioning Automated Demand Response Systems  

E-Print Network (OSTI)

al: Installation and Commissioning Automated Demand ResponseConference on Building Commissioning: April 22 – 24, 2008al: Installation and Commissioning Automated Demand Response

Kiliccote, Sila; Global Energy Partners; Pacific Gas and Electric Company

2008-01-01T23:59:59.000Z

369

EIA - Annual Energy Outlook 2009 - Electricity Demand  

Gasoline and Diesel Fuel Update (EIA)

data Rate of Electricity Demand Growth Slows, Following the Historical Trend Electricity demand fluctuates in the short term in response to business cycles, weather conditions,...

370

Demand Response as a System Reliability Resource  

NLE Websites -- All DOE Office Websites (Extended Search)

Demand Response as a System Reliability Resource Title Demand Response as a System Reliability Resource Publication Type Report Year of Publication 2012 Authors Eto, Joseph H.,...

371

Option Value of Electricity Demand Response  

E-Print Network (OSTI)

Oakland CA, December. PJM Demand Side Response WorkingPrice Response Program a PJM Economic Load Response ProgramLoad Response Statistics PJM Demand Response Working Group

Sezgen, Osman; Goldman, Charles; Krishnarao, P.

2005-01-01T23:59:59.000Z

372

Retail Demand Response in Southwest Power Pool  

E-Print Network (OSTI)

Regulatory Commission (FERC) 2006. “Assessment of DemandRegulatory Commission (FERC) 2007. “Assessment of DemandRegulatory Commission (FERC) 2008a. “Wholesale Competition

Bharvirkar, Ranjit

2009-01-01T23:59:59.000Z

373

California Energy Demand Scenario Projections to 2050  

E-Print Network (OSTI)

29 5.6. Peak and hourly demand43 6.6. Peak and seasonal demandthe average percent of peak demand) significantly impact the

McCarthy, Ryan; Yang, Christopher; Ogden, Joan M.

2008-01-01T23:59:59.000Z

374

Energy and Water Development Appropriation Bill, 1987. Introduced in the Senate, Ninety-Ninth Congress, Second Session, September 15, 1986  

SciTech Connect

The Senate Appropriations Committee report on H.R. 5162 includes information pertaining to the bill as well as suggested amendments to the nearly $15.55 billion bill passed by the House. The four titles of the bill cover appropriations for the Army Corps of Engineers, the Departments of Interior and Energy, and independent agencies. Detailed budget items and committee recommendations make up the bulk of the report.

1986-01-01T23:59:59.000Z

375

Water demand management in Kuwait  

E-Print Network (OSTI)

Kuwait is an arid country located in the Middle East, with limited access to water resources. Yet water demand per capita is much higher than in other countries in the world, estimated to be around 450 L/capita/day. There ...

Milutinovic, Milan, M. Eng. Massachusetts Institute of Technology

2006-01-01T23:59:59.000Z

376

Demand-Side Management Glossary  

Science Conference Proceedings (OSTI)

In recent years, demand-side management (DSM) programs have grown in significance within the U.S. electric power industry. Such rapid growth has resulted in new terms, standards, and vocabulary used by DSM professionals. This report is a first attempt to provide a consistent set of definitions for the expanding DSM terminology.

1992-11-01T23:59:59.000Z

377

4 kW Test of Solid Oxide Electrolysis Stacks with Advanced Electrode-Supported Cells  

DOE Green Energy (OSTI)

A new test stand has been developed at the Idaho National Laboratory for multi-kW testing of solid oxide electrolysis stacks. This test stand will initially be operated at the 4 KW scale. The 4 kW tests will include two 60-cell stacks operating in parallel in a single hot zone. The stacks are internally manifolded with an inverted-U flow pattern and an active area of 100 cm2 per cell. Process gases to and from the two stacks are distributed from common inlet/outlet tubing using a custom base manifold unit that also serves as the bottom current collector plate. The solid oxide cells incorporate a negative-electrode-supported multi-layer design with nickel-zirconia cermet negative electrodes, thin-film yttria-stabilized zirconia electrolytes, and multi-layer lanthanum ferrite-based positive electrodes. Treated metallic interconnects with integral flow channels separate the cells and electrode gases. Sealing is accomplished with compliant mica-glass seals. A spring-loaded test fixture is used for mechanical stack compression. Due to the power level and the large number of cells in the hot zone, process gas flow rates are high and heat recuperation is required to preheat the cold inlet gases upstream of the furnace. Heat recuperation is achieved by means of two inconel tube-in-tube counter-flow heat exchangers. A current density of 0.3 A/cm2 will be used for these tests, resulting in a hydrogen production rate of 25 NL/min. Inlet steam flow rates will be set to achieve a steam utilization value of 50%. The 4 kW test will be performed for a minimum duration of 1000 hours in order to document the long-term durability of the stacks. Details of the test apparatus and initial results will be provided.

J. E. O'Brien; X. Zhang; G. K. Housley; L. Moore-McAteer; G. Tao

2012-06-01T23:59:59.000Z

378

Performance Assessment of the 6kW Ultra Capacitor Based Bonitron Ride-Through System  

Science Conference Proceedings (OSTI)

The objective of this report is to describe and document the operation and performance of the Bonitron adjustable speed drive voltage sag protection device. This report will describe the different tests that were conducted and their results to characterize the Bonitron. The tests that were conducted include voltage sag and swell protection, interruption, re-closure, and life cycle tests. Additional characterization tests will also be discussed. The Bonitron was tested at 100% load using a 7.5kW/10Hp ...

2012-12-31T23:59:59.000Z

379

High Temperature Electrolysis 4 kW Experiment Design, Operation, and Results  

SciTech Connect

This report provides results of long-term stack testing completed in the new high-temperature steam electrolysis multi-kW test facility recently developed at INL. The report includes detailed descriptions of the piping layout, steam generation and delivery system, test fixture, heat recuperation system, hot zone, instrumentation, and operating conditions. This facility has provided a demonstration of high-temperature steam electrolysis operation at the 4 kW scale with advanced cell and stack technology. This successful large-scale demonstration of high-temperature steam electrolysis will help to advance the technology toward near-term commercialization.

J.E. O'Brien; X. Zhang; K. DeWall; L. Moore-McAteer; G. Tao

2012-09-01T23:59:59.000Z

380

Calculating Energy and Demand Retrofit Savings for Victoria High School: Interim Report  

E-Print Network (OSTI)

As part of the LoanSTAR program, Victoria High School in Victoria, Texas underwent two retrofits: a) an absorption chiller was changed to an electric vapor compression chiller, and b) an EMCS system was installed after about 5 months in the post retrofit period. Moreover, retrofit savings calculation was complex since pre-retrofit data consisted of only monthly utility data while hourly monitored data are available for the post-retrofit period. This report describes the method in which we have performed retrofit energy and demand savings in Victoria High School. A previous report described the procedure adopted when no pre-retrofit data are available. We have only used Unnormalized Utility Bills Comparison ,or the Level-0 approach to determine electricity (energy and demand) and gas energy savings for VHS.

Liu, Y.; Reddy, T. A.; Katipamula, S.; Claridge, D. E.

1992-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "kw billing demand" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Money for Research, Not for Energy Bills: Finding Energy and Cost Savings in High Performance Computer Facility Designs  

E-Print Network (OSTI)

Money for Research, Not Energy Bills: Finding Energy andUniversity of California. Money for Research, Not for Energy2014 and potentially siphons money from other priorities to

Sartor, Dale

2011-01-01T23:59:59.000Z

382

Secretary of Energy Samuel W. Bodman's Statement on the First Meeting of the House-Senate Energy Bill Conference Committee  

Energy.gov (U.S. Department of Energy (DOE))

WASHINGTON, D.C. - Secretary of Energy Samuel W. Bodman today released the following statement on the first meeting of the House-Senate Energy Bill Conference Committee:

383

FY2013Appropriations Update: House andSenate Committees ApproveEnergy-WaterDevelopment AppropriationsBill  

E-Print Network (OSTI)

allocation. The priorities for the House bill include DOE's nuclear security programs, programs to address water infrastructure, clean energy technologies, and nuclear nonproliferation and nuclear weapons

384

Demand Dispatch — Intelligent Demand for a More Efficient Grid  

E-Print Network (OSTI)

This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference therein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed therein do not necessarily state or reflect those of the United States Government or any agency thereof. Demand Dispatch: Intelligent Demand for a More Efficient Grid

Keith Dodrill

2011-01-01T23:59:59.000Z

385

Optimal Control of Distributed Energy Resources and Demand Response under Uncertainty  

Science Conference Proceedings (OSTI)

We take the perspective of a microgrid that has installed distribution energy resources (DER) in the form of distributed generation with combined heat and power applications. Given uncertain electricity and fuel prices, the microgrid minimizes its expected annual energy bill for various capacity sizes. In almost all cases, there is an economic and environmental advantage to using DER in conjunction with demand response (DR): the expected annualized energy bill is reduced by 9percent while CO2 emissions decline by 25percent. Furthermore, the microgrid's risk is diminished as DER may be deployed depending on prevailing market conditions and local demand. In order to test a policy measure that would place a weight on CO2 emissions, we use a multi-criteria objective function that minimizes a weighted average of expected costs and emissions. We find that greater emphasis on CO2 emissions has a beneficial environmental impact only if DR is available and enough reserve generation capacity exists. Finally, greater uncertainty results in higher expected costs and risk exposure, the effects of which may be mitigated by selecting a larger capacity.

Siddiqui, Afzal; Stadler, Michael; Marnay, Chris; Lai, Judy

2010-06-01T23:59:59.000Z

386

The alchemy of demand response: turning demand into supply  

Science Conference Proceedings (OSTI)

Paying customers to refrain from purchasing products they want seems to run counter to the normal operation of markets. Demand response should be interpreted not as a supply-side resource but as a secondary market that attempts to correct the misallocation of electricity among electric users caused by regulated average rate tariffs. In a world with costless metering, the DR solution results in inefficiency as measured by deadweight losses. (author)

Rochlin, Cliff

2009-11-15T23:59:59.000Z

387

US Residential Energy Demand and Energy Efficiency: A Stochastic Demand Frontier  

E-Print Network (OSTI)

US Residential Energy Demand and Energy Efficiency: A Stochastic Demand Frontier Approach Massimo www.cepe.ethz.ch #12;US Residential Energy Demand and Energy Efficiency: A Stochastic Demand Frontier Approach Page 1 of 25 US Residential Energy Demand and Energy Efficiency: A Stochastic Demand Frontier

388

Short-Term Energy Outlook Supplement: Summer 2013 Outlook for Residential Electric Bills  

U.S. Energy Information Administration (EIA) Indexed Site

Summer 2013 Outlook for Residential Summer 2013 Outlook for Residential Electric Bills June 2013 Independent Statistics & Analysis www.eia.gov U.S. Department of Energy Washington, DC 20585 U.S. Energy Information Administration | STEO Supplement: Summer 2013 Outlook for Residential Electric Bills i This report was prepared by the U.S. Energy Information Administration (EIA), the statistical and analytical agency within the U.S. Department of Energy. By law, EIA's data, analyses, and forecasts are independent of approval by any other officer or employee of the United States Government. The views in this report therefore should not be construed as representing those of the Department of Energy or other federal agencies. June 2013 U.S. Energy Information Administration | STEO Supplement: Summer 2013 Outlook for Residential Electric Bills 1

389

Look Up to See Your Bills Go Down: Making Your Attic More Efficient |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Look Up to See Your Bills Go Down: Making Your Attic More Efficient Look Up to See Your Bills Go Down: Making Your Attic More Efficient Look Up to See Your Bills Go Down: Making Your Attic More Efficient July 18, 2011 - 5:29pm Addthis Allison Casey Senior Communicator, NREL This year at my house, we have been on a quest to make our attic more energy efficient. I think we realized just how much this unseen area contributes to our overall comfort -not to mention what we pay to heat and cool the house. The first thing we did was install more insulation this winter. In addition to the tax credits we'll be able to claim, there were several incentives available from our state and utility that made it a great time for us to make this improvement. Following the installation, we noticed an immediate improvement in the overall comfort of our home and the furnace seemed to

390

Day Two of 2012 ARPA-E Summit Will Feature Bill Gates, Secretary Chu and  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Two of 2012 ARPA-E Summit Will Feature Bill Gates, Secretary Two of 2012 ARPA-E Summit Will Feature Bill Gates, Secretary Chu and America's Top Energy Thought Leaders Day Two of 2012 ARPA-E Summit Will Feature Bill Gates, Secretary Chu and America's Top Energy Thought Leaders February 28, 2012 - 7:02am Addthis Washington D.C. - This week, the Advanced Research Projects Agency - Energy (ARPA-E) is hosting its third annual Energy Innovation Summit, which is designed to unite key players from all sectors of America's energy innovation community to share ideas for how to lead the world in the development of next generation clean energy technologies, develop our nation's energy resources, and build an American economy that lasts. Tomorrow's full agenda with speakers is below. For specific press requests, please contact Keri Fulton at keri.fulton@hq.doe.gov.

391

Tapping Solar for Hot Water and Cheaper Bills for Puerto Rico | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tapping Solar for Hot Water and Cheaper Bills for Puerto Rico Tapping Solar for Hot Water and Cheaper Bills for Puerto Rico Tapping Solar for Hot Water and Cheaper Bills for Puerto Rico November 3, 2010 - 10:00am Addthis Stephen Graff Former Writer & editor for Energy Empowers, EERE What does this mean for me? 150 new jobs. 1200 solar water heaters installed. In Puerto Rico, solar water heaters have been popular for decades. But even with energy savings, not everyone can afford one. Through a new Recovery Act-funded program for the island, more families are showering with water heated by the sun. The U.S. Department of Energy's new Weatherization Assistance Program (WAP) in Puerto Rico has made it a priority to install the systems in homes of income-eligible residents, as part of its weatherization assistance services. The Puerto Rico Energy Affairs Administration (PREAA), which

392

New Independent Analysis Confirms Climate Bill Costs About a Postage Stamp  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Independent Analysis Confirms Climate Bill Costs About a Independent Analysis Confirms Climate Bill Costs About a Postage Stamp a Day New Independent Analysis Confirms Climate Bill Costs About a Postage Stamp a Day August 4, 2009 - 12:00am Addthis Washington, D.C. - A new analysis by the independent, non-partisan Energy Information Agency confirms findings by earlier reports from the Congressional Budget Office and the Environmental Protection Agency that the Waxman-Markey energy and climate legislation will cost Americans roughly the same as a postage stamp a day. The EIA analysis projects an increased cost of about $83 (adjusted for inflation) by 2030 -- or roughly 23 cents a day. Energy Secretary Steven Chu made the following statement: "This new, independent and highly respected analysis confirms the findings

393

Energy Secretary Bodman Heads to West Virginia to Promote Energy Bill |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Heads to West Virginia to Promote Energy Heads to West Virginia to Promote Energy Bill Energy Secretary Bodman Heads to West Virginia to Promote Energy Bill July 7, 2005 - 2:00pm Addthis Secretary Promotes Energizing America for Energy Security BELLE, WV - Secretary of Energy Samuel W. Bodman today traveled to West Virginia to urge the Congress to pass comprehensive energy legislation that is now before them. The bill reflects many of the principles of President Bush's national energy policy including the diversification of America's energy supply to include more alternative and renewable sources; encouraging energy efficiency and conservation; promoting more domestic production in environmentally responsible ways; and modernizing our electricity delivery system to minimize the risk of blackouts. President

394

Day Two of 2012 ARPA-E Summit Will Feature Bill Gates, Secretary Chu and  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Day Two of 2012 ARPA-E Summit Will Feature Bill Gates, Secretary Day Two of 2012 ARPA-E Summit Will Feature Bill Gates, Secretary Chu and America's Top Energy Thought Leaders Day Two of 2012 ARPA-E Summit Will Feature Bill Gates, Secretary Chu and America's Top Energy Thought Leaders February 28, 2012 - 7:02am Addthis Washington D.C. - This week, the Advanced Research Projects Agency - Energy (ARPA-E) is hosting its third annual Energy Innovation Summit, which is designed to unite key players from all sectors of America's energy innovation community to share ideas for how to lead the world in the development of next generation clean energy technologies, develop our nation's energy resources, and build an American economy that lasts. Tomorrow's full agenda with speakers is below. For specific press requests, please contact Keri Fulton at keri.fulton@hq.doe.gov.

395

New Infographic and Projects to Keep Your Energy Bills Out of Hot Water |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Infographic and Projects to Keep Your Energy Bills Out of Hot Infographic and Projects to Keep Your Energy Bills Out of Hot Water New Infographic and Projects to Keep Your Energy Bills Out of Hot Water April 19, 2013 - 3:21pm Addthis New Energy Saver 101 infographic lays out the different types of water heaters on the market and will help you figure out how to select the best model for your home. Download a high-resolution version of the infographic. | Infographic by Sarah Gerrity. New Energy Saver 101 infographic lays out the different types of water heaters on the market and will help you figure out how to select the best model for your home. Download a high-resolution version of the infographic. | Infographic by Sarah Gerrity. Rebecca Matulka Rebecca Matulka Digital Communications Specialist, Office of Public Affairs

396

How to Save on Energy Bills When Buying a New Home | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

How to Save on Energy Bills When Buying a New Home How to Save on Energy Bills When Buying a New Home How to Save on Energy Bills When Buying a New Home June 26, 2013 - 2:09pm Addthis When considering a new home, keep energy efficiency in mind. | Photo courtesy of Warren Gretz, NREL 08742 When considering a new home, keep energy efficiency in mind. | Photo courtesy of Warren Gretz, NREL 08742 This chart shows how much energy a typical appliance uses per year and its corresponding cost based on national averages. For example, a refrigerator uses almost five times the electricity the average television uses. This chart shows how much energy a typical appliance uses per year and its corresponding cost based on national averages. For example, a refrigerator uses almost five times the electricity the average television uses.

397

VP 100: Smart Meters Will Help Customers Avoid High Electric Bills |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Smart Meters Will Help Customers Avoid High Electric Bills Smart Meters Will Help Customers Avoid High Electric Bills VP 100: Smart Meters Will Help Customers Avoid High Electric Bills October 4, 2010 - 3:00pm Addthis An employee installs a smart meter as part of a smart grid initiative by EPB. The project is supporting 390 jobs in the Chattanooga area. | Photo courtesy of EPB An employee installs a smart meter as part of a smart grid initiative by EPB. The project is supporting 390 jobs in the Chattanooga area. | Photo courtesy of EPB Kevin Craft What are the key facts? EPB will install approximately 170,000 smart meters and 1,500 automated switches. They have the potential to provide a $300 million value to EPB and customers over a ten-year period. "Last winter I received a call from my son saying he had a $400 electric

398

Look Up to See Your Bills Go Down: Making Your Attic More Efficient |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Look Up to See Your Bills Go Down: Making Your Attic More Efficient Look Up to See Your Bills Go Down: Making Your Attic More Efficient Look Up to See Your Bills Go Down: Making Your Attic More Efficient July 18, 2011 - 5:29pm Addthis Allison Casey Senior Communicator, NREL This year at my house, we have been on a quest to make our attic more energy efficient. I think we realized just how much this unseen area contributes to our overall comfort -not to mention what we pay to heat and cool the house. The first thing we did was install more insulation this winter. In addition to the tax credits we'll be able to claim, there were several incentives available from our state and utility that made it a great time for us to make this improvement. Following the installation, we noticed an immediate improvement in the overall comfort of our home and the furnace seemed to

399

VP 100: Smart Meters Will Help Customers Avoid High Electric Bills |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

VP 100: Smart Meters Will Help Customers Avoid High Electric Bills VP 100: Smart Meters Will Help Customers Avoid High Electric Bills VP 100: Smart Meters Will Help Customers Avoid High Electric Bills October 4, 2010 - 3:00pm Addthis An employee installs a smart meter as part of a smart grid initiative by EPB. The project is supporting 390 jobs in the Chattanooga area. | Photo courtesy of EPB An employee installs a smart meter as part of a smart grid initiative by EPB. The project is supporting 390 jobs in the Chattanooga area. | Photo courtesy of EPB Kevin Craft What are the key facts? EPB will install approximately 170,000 smart meters and 1,500 automated switches. They have the potential to provide a $300 million value to EPB and customers over a ten-year period. "Last winter I received a call from my son saying he had a $400 electric

400

How to Save on Energy Bills When Buying a New Home | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

How to Save on Energy Bills When Buying a New Home How to Save on Energy Bills When Buying a New Home How to Save on Energy Bills When Buying a New Home June 26, 2013 - 2:09pm Addthis When considering a new home, keep energy efficiency in mind. | Photo courtesy of Warren Gretz, NREL 08742 When considering a new home, keep energy efficiency in mind. | Photo courtesy of Warren Gretz, NREL 08742 This chart shows how much energy a typical appliance uses per year and its corresponding cost based on national averages. For example, a refrigerator uses almost five times the electricity the average television uses. This chart shows how much energy a typical appliance uses per year and its corresponding cost based on national averages. For example, a refrigerator uses almost five times the electricity the average television uses.

Note: This page contains sample records for the topic "kw billing demand" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Utility bill comprehension in the commercial and industrialsector: results of field research  

SciTech Connect

This paper presents the results of interviews conducted with 44 business people in 10 states to examine the use of the utility bill as an information mechanism for providing businesses with the relationship between energy consumption and cost. Our results indicate that there are significant barriers to the use of the utility bill as an information tool for energy consumers. Furthermore, we found significant variations among respondents in the information desired from the bill, and differences in decision-making criteria for investments aimed at reducing energy consumption and for those aimed at other forms of waste minimization. These results call into question the applicability of standard market theories in the purchase of energy by most businesses.

Payne, Christopher T.

2000-06-02T23:59:59.000Z

402

Microsoft PowerPoint - 03.2010_Metering Billing MDM America.pptx  

NLE Websites -- All DOE Office Websites (Extended Search)

METERING BILLING/MDM AMERICA METERING BILLING/MDM AMERICA Back-up Generation Sources (BUGS) Prepared by Steve Pullins March 9, 2010 Metering, Billing/MDM America - San Diego, CA This material is based upon work supported by the Department of Energy under Award Number DE- Department of Energy under Award Number DE AC26-04NT41817 This presentation was prepared as an account of work sponsored by an agency of This presentation was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed or represents

403

High Water Heating Bills on Lockdown at Idaho Jail | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

High Water Heating Bills on Lockdown at Idaho Jail High Water Heating Bills on Lockdown at Idaho Jail High Water Heating Bills on Lockdown at Idaho Jail August 19, 2010 - 12:05pm Addthis The Blaine County Public Safety Facility houses between 60 and 80 prisoners and roughly 30 staffers. | Photo courtesy of Blaine The Blaine County Public Safety Facility houses between 60 and 80 prisoners and roughly 30 staffers. | Photo courtesy of Blaine Lindsay Gsell What does this project do? The new solar thermal hot water system will provide nearly 70 percent of the BTUs required for heating 600,000 gallons of water for the jail annually, saving the county more than $4,000 a year in electricity costs at current rates. In Hailey, Idaho, one 330,000 square foot building - the Blaine County Public Safety Facility - accounts for the county's highest operational

404

Day Three of 2012 ARPA-E Summit Will Feature President Bill Clinton, ARPA-E  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Day Three of 2012 ARPA-E Summit Will Feature President Bill Day Three of 2012 ARPA-E Summit Will Feature President Bill Clinton, ARPA-E Director Majumdar, and America's Top Energy Thought Leaders Day Three of 2012 ARPA-E Summit Will Feature President Bill Clinton, ARPA-E Director Majumdar, and America's Top Energy Thought Leaders February 29, 2012 - 6:59am Addthis Washington D.C. - This week, the Advanced Research Projects Agency - Energy (ARPA-E) is hosting its third annual Energy Innovation Summit. With over 2,400 registered attendees, the Summit is designed to unite key players from all sectors of America's energy innovation community to share ideas for how to lead the world in the development of next generation clean energy technologies, develop our nation's energy resources, and build an American economy that lasts.

405

Wind Turbine Generator System Acoustic Noise Test Report for the Gaia Wind 11-kW Wind Turbine  

DOE Green Energy (OSTI)

This report details the acoustic noise test conducted on the Gaia-Wind 11-kW wind turbine at the National Wind Technology Center. The test turbine is a two- bladed, downwind wind turbine with a rated power of 11 kW. The test turbine was tested in accordance with the International Electrotechnical Commission standard, IEC 61400-11 Ed 2.1 2006-11 Wind Turbine Generator Systems -- Part 11 Acoustic Noise Measurement Techniques.

Huskey, A.

2011-11-01T23:59:59.000Z

406

Optimal Sizing of Energy Storage and Photovoltaic Power Systems for Demand Charge Mitigation (Poster)  

DOE Green Energy (OSTI)

Commercial facility utility bills are often a strong function of demand charges -- a fee proportional to peak power demand rather than total energy consumed. In some instances, demand charges can constitute more than 50% of a commercial customer's monthly electricity cost. While installation of behind-the-meter solar power generation decreases energy costs, its variability makes it likely to leave the peak load -- and thereby demand charges -- unaffected. This then makes demand charges an even larger fraction of remaining electricity costs. Adding controllable behind-the-meter energy storage can more predictably affect building peak demand, thus reducing electricity costs. Due to the high cost of energy storage technology, the size and operation of an energy storage system providing demand charge management (DCM) service must be optimized to yield a positive return on investment (ROI). The peak demand reduction achievable with an energy storage system depends heavily on a facility's load profile, so the optimal configuration will be specific to both the customer and the amount of installed solar power capacity. We explore the sensitivity of DCM value to the power and energy levels of installed solar power and energy storage systems. An optimal peak load reduction control algorithm for energy storage systems will be introduced and applied to historic solar power data and meter load data from multiple facilities for a broad range of energy storage system configurations. For each scenario, the peak load reduction and electricity cost savings will be computed. From this, we will identify a favorable energy storage system configuration that maximizes ROI.

Neubauer, J.; Simpson, M.

2013-10-01T23:59:59.000Z

407

Data:Bb1aec2f-1abb-47a7-a8ca-813778d17c3f | Open Energy Information  

Open Energy Info (EERE)

aec2f-1abb-47a7-a8ca-813778d17c3f aec2f-1abb-47a7-a8ca-813778d17c3f No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Greenwood Commissioners-Pub Wk Effective date: 2008/09/01 End date if known: Rate name: Large Commercial service rate Sector: Commercial Description: MINIMUM CHARGE: The minimum monthly charge shall be the "Facility Charge". The following Tiered Demand Charge schedule is applied: First 30 kW of Billing Demand ................................... $1.890 Per kW. All Over 30 kW of Billing Demand ............................. $2.956 Per kW. DETERMINATION OF BILLING DEMAND: The "Billing Demand" for the billing period shall be the maximum integrated thirty minute demand recorded during the billing period for which the bill is rendered.

408

Energy Efficiency & On-Bill Financing for Samll Business & Residential  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Efficiency Energy Efficiency & On-Bill Financing For Small Businesses & Residential Presentation for: The Second US-China Energy Efficiency Forum Berkeley, California 05/06/2011 May 5-6, 2011|Lawrence Berkeley National Laboratory, Berkeley, California Connecticut Energy Efficiency Fund (CEEF) Connecticut's Energy Efficiency Programs are funded by a Charge on Customer's electric bills. The Programs are designed to help customers manage their energy usage and cost. May 5-6, 2011|Lawrence Berkeley National Laboratory, Berkeley, California Small Business Objective  PROVIDE > COST-EFFECTIVE, turn-key CONSERVATION and LOAD MANAGEMENT SERVICES to SMALL C&I CUSTOMERS.  What qualifies as a SMALL BUSINESS?

409

Energy Demand | Open Energy Information  

Open Energy Info (EERE)

Energy Demand Energy Demand Jump to: navigation, search Click to return to AEO2011 page AEO2011 Data Figure 55 From AEO2011 report . Market Trends Growth in energy use is linked to population growth through increases in housing, commercial floorspace, transportation, and goods and services. These changes affect not only the level of energy use, but also the mix of fuels used. Energy consumption per capita declined from 337 million Btu in 2007 to 308 million Btu in 2009, the lowest level since 1967. In the AEO2011 Reference case, energy use per capita increases slightly through 2013, as the economy recovers from the 2008-2009 economic downturn. After 2013, energy use per capita declines by 0.3 percent per year on average, to 293 million Btu in 2035, as higher efficiency standards for vehicles and

410

Q:\asufinal_0107_demand.vp  

Gasoline and Diesel Fuel Update (EIA)

00 00 (AEO2000) Assumptions to the January 2000 With Projections to 2020 DOE/EIA-0554(2000) Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Macroeconomic Activity Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 International Energy Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Household Expenditures Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Residential Demand Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Commercial Demand Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Industrial Demand Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Transportation Demand Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Electricity Market Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Oil and Gas Supply Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 Natural Gas Transmission and Distribution

411

Demand Response and Risk Management  

Science Conference Proceedings (OSTI)

For several decades, power companies have deployed various types of demand response (DR), such as interruptible contracts, and there is substantial ongoing research and development on sophisticated mechanisms for triggering DR. In this white paper, EPRI discusses the increasing use of electricity DR in the power industry and how this will affect the practice of energy risk management. This paper outlines 1) characteristics of a common approach to energy risk management, 2) the variety of types of DR impl...

2008-12-18T23:59:59.000Z

412

Building Technologies Office: Integrated Predictive Demand Response  

NLE Websites -- All DOE Office Websites (Extended Search)

Integrated Predictive Integrated Predictive Demand Response Controller Research Project to someone by E-mail Share Building Technologies Office: Integrated Predictive Demand Response Controller Research Project on Facebook Tweet about Building Technologies Office: Integrated Predictive Demand Response Controller Research Project on Twitter Bookmark Building Technologies Office: Integrated Predictive Demand Response Controller Research Project on Google Bookmark Building Technologies Office: Integrated Predictive Demand Response Controller Research Project on Delicious Rank Building Technologies Office: Integrated Predictive Demand Response Controller Research Project on Digg Find More places to share Building Technologies Office: Integrated Predictive Demand Response Controller Research Project on AddThis.com...

413

Demand Trading: Measurement, Verification, and Settlement (MVS)  

Science Conference Proceedings (OSTI)

With this report, EPRI's trilogy of publications on demand trading is complete. The first report (1006015), the "Demand Trading Toolkit," documented how to conduct demand trading based on price. The second report (1001635), "Demand Trading: Building Liquidity," focused on the problem of liquidity in the energy industry and developed the Demand Response Resource Bank concept for governing electricity markets based on reliability. The present report focuses on the emerging price/risk partnerships in electr...

2004-03-18T23:59:59.000Z

414

Automated Demand Response Opportunities in Wastewater Treatment Facilities  

E-Print Network (OSTI)

Interoperable Automated Demand Response Infrastructure,study of automated demand response in wastewater treatmentopportunities for demand response control strategies in

Thompson, Lisa

2008-01-01T23:59:59.000Z

415

Opportunities, Barriers and Actions for Industrial Demand Response in California  

E-Print Network (OSTI)

and Techniques for Demand Response, report for theand Reliability Demand Response Programs: Final Report.Demand Response

McKane, Aimee T.

2009-01-01T23:59:59.000Z

416

Northwest Open Automated Demand Response Technology Demonstration Project  

E-Print Network (OSTI)

Report 2009. Open Automated Demand Response Communicationsand Techniques for Demand Response. California Energyand S. Kiliccote. Estimating Demand Response Load Impacts:

Kiliccote, Sila

2010-01-01T23:59:59.000Z

417

Effects of the drought on California electricity supply and demand  

E-Print Network (OSTI)

DEMAND . . . .Demand for Electricity and Power PeakDemand . . • . . ELECTRICITY REQUIREMENTS FOR AGRICULTUREResults . . Coriclusions ELECTRICITY SUPPLY Hydroelectric

Benenson, P.

2010-01-01T23:59:59.000Z

418

Northwest Open Automated Demand Response Technology Demonstration Project  

E-Print Network (OSTI)

14 Peak Demand Baselinewinter morning electric peak demand in commercial buildings.California to reduce peak demand during summer afternoons,

Kiliccote, Sila

2010-01-01T23:59:59.000Z

419

Oil drilling to use LSU process Show Caption BILL FEIG/THE ADVOCATE  

E-Print Network (OSTI)

BUSINESS Oil drilling to use LSU process Show Caption BILL FEIG/THE ADVOCATE Advocate staff process to make wood-plastic composites has found a new application in the oil and gas business to turn used plastic motor oil containers and wood waste into a strong composite material that can be used

420

GREEDY HEURISTICS FOR DETERMINING A PRODUCT FAMILY BILL OF Radwan El Hadj Khalaf  

E-Print Network (OSTI)

explore this production policy where modules are manufactured in distant location facilities for cost in selecting a set of modules that will be manufactured in distant facilities and shipped in a nearby location on exploring the finished product set and determining the most suitable bill of materials for each one and (2

Paris-Sud XI, Université de

Note: This page contains sample records for the topic "kw billing demand" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

NRRI's Bill Berguson promotes fast-growing trees as part of America's new energy future.  

E-Print Network (OSTI)

to increase energy independence with new biorefinery industries and sustainable new crops. A study undertaken Commission with representatives from the union, paper industry, legislature, University, energy company andNRRI's Bill Berguson promotes fast-growing trees as part of America's new energy future. Winter

Netoff, Theoden

422

Price-elastic demand in deregulated electricity markets  

E-Print Network (OSTI)

by the amount of electricity demand that is settled forward.unresponsive demand side, electricity demand has to be metxed percentage of overall electricity demand. The ISO, thus,

Siddiqui, Afzal S.

2003-01-01T23:59:59.000Z

423

Building Energy Software Tools Directory : Demand Response Quick...  

NLE Websites -- All DOE Office Websites (Extended Search)

Demand Response Quick Assessment Tool Back to Tool Demand response quick assessment tool screenshot Demand response quick assessment tool screenshot Demand response quick...

424

Automated Demand Response Strategies and Commissioning Commercial Building Controls  

E-Print Network (OSTI)

Braun (Purdue). 2004. Peak demand reduction from pre-coolingthe average and maximum peak demand savings. The electricityuse charges, demand ratchets, peak demand charges, and other

Piette, Mary Ann; Watson, David; Motegi, Naoya; Kiliccote, Sila; Linkugel, Eric

2006-01-01T23:59:59.000Z

425

Development of a 402.5 MHz 140 kW Inductive Output Tube  

SciTech Connect

This report contains the results of Phase I of an SBIR to develop a Pulsed Inductive Output Tube (IOT) with 140 kW at 400 MHz for powering H-proton beams. A number of sources, including single beam and multiple beam klystrons, can provide this power, but the IOT provides higher efficiency. Efficiencies exceeding 70% are routinely achieved. The gain is typically limited to approximately 24 dB; however, the availability of highly efficient, solid state drivers reduces the significance of this limitation, particularly at lower frequencies. This program initially focused on developing a 402 MHz IOT; however, the DOE requirement for this device was terminated during the program. The SBIR effort was refocused on improving the IOT design codes to more accurately simulate the time dependent behavior of the input cavity, electron gun, output cavity, and collector. Significant improvement was achieved in modeling capability and simulation accuracy.

R. Lawrence Ives; Michael Read, Robert Jackson

2012-05-09T23:59:59.000Z

426

Tower Design Load Verification on a 1-kW Wind Turbine: Preprint  

DOE Green Energy (OSTI)

Wind turbine testing at the National Wind Technology Center (NWTC) has been done to characterize both tower top loads and thrust loads for small wind turbines, which is part of an ongoing effort to model and predict small wind turbine behavior and the resulting stresses imposed on the supporting tower. To these ends, a 1-kW furling wind turbine mounted on a 10-meter tower was instrumented and monitored via a data acquisition system for nearly a year. This test was conducted to verify the design loads as predicted by the simple design equations provided in the draft revision of the International Electrotechnical Commission (IEC) Small Wind Turbine Safety Standard 61400-02 CDV (hereafter called ''the draft Standard''). Data were captured for several operating conditions covered by the draft Standard. This paper addresses the collected data and what conclusions can be made from it.

Prascher, D.; Huskey, A.

2004-11-01T23:59:59.000Z

427

A 350 MHz, 200 kW CW, Multiple Beam Inductive Output Tube - Final Report  

SciTech Connect

This program developed a 200 kW CW, 350 MHz, multiple beam inductive output tube (MBIOT) for driving accelerator cavities. The MBIOT operates at 30 kV with a gain of 23 dB. The estimated efficiency is 70%. The device uses seven electron beams, each transmitting 1.4 A of current. The tube is approximately six feet long and weighs approximately 400 lbs. The prototype device will be evaluated as a potential RF source for the Advanced Photon Source at Argonne National Laboratory (ANL). Because of issues related to delivery of the electron guns, it was not possible to complete assembly and test of the MBIOT during the Phase II program. The device is being completed with support from Calabazas Creek Research, Inc., Communications & Power Industries, LLC. and the Naval Surface Weapons Center (NSWC) in Dahlgren, VA. The MBIOT will be initially tested at NSWC before delivery to ANL. The testing at NSWC is scheduled for February 2013.

R.Lawrece Ives; George Collins; David Marsden Michael Read; Edward Eisen; Takuchi Kamura, Philipp Borchard

2012-11-28T23:59:59.000Z

428

Enertech 2-kW high-reliability wind system. Phase II. Fabrication and testing  

SciTech Connect

A high-reliability wind machine rated for 2 kW in a 9 m/s wind has been developed. Activities are summarized that are centered on the fabrication and testing of prototypes of the wind machine. The test results verified that the wind machine met the power output specification and that the variable-pitch rotor effectively controlled the rotor speed for wind speeds up to 50 mph. Three prototypes of the wind machine were shipped to the Rocky Flats test center in September through November of 1979. Work was also performed to reduce the start-up wind speed. The start-up wind speed to the Enertech facility has been reduced to 4.5 m/s.

Cordes, J.A.; Johnson, B.A.

1981-06-01T23:59:59.000Z

429

Test Results From The Idaho National Laboratory 15kW High Temperature Electrolysis Test Facility  

DOE Green Energy (OSTI)

A 15kW high temperature electrolysis test facility has been developed at the Idaho National Laboratory under the United States Department of Energy Nuclear Hydrogen Initiative. This facility is intended to study the technology readiness of using high temperature solid oxide cells for large scale nuclear powered hydrogen production. It is designed to address larger-scale issues such as thermal management (feed-stock heating, high temperature gas handling, heat recuperation), multiple-stack hot zone design, multiple-stack electrical configurations, etc. Heat recuperation and hydrogen recycle are incorporated into the design. The facility was operated for 1080 hours and successfully demonstrated the largest scale high temperature solid-oxide-based production of hydrogen to date.

Carl M. Stoots; Keith G. Condie; James E. O'Brien; J. Stephen Herring; Joseph J. Hartvigsen

2009-07-01T23:59:59.000Z

430

Verification test of a 25kW class SOFC cogeneration system  

DOE Green Energy (OSTI)

Osaka Gas and Tokyo Gas have high expectations for natural-gas-fueled Solid Oxide Fuel Cell (SOFC) cogeneration systems. SOFC offers many advantages for on-site cogeneration systems, such as high electrical efficiency, high quality by-product heat and low emissions. They are now executing a joint development program with Westinghouse Electric Corporation (hereinafter called as WELCO). This program is aimed to verify a 25kW class SOFC cogeneration system. This system, which was modified by replacing previous zirconia porous support tube cells (PST cells) with newly designed air electrode supported cells (AES cells), commenced operation on March 21, 1995. The system has been successfully operated for 13,100 hours as of February 7, 1997. This paper presents the performance evaluation of the new AES cells and the results of system operation at WELCO.

Yokoyama, H. [Osaka Gas Company Limited (Japan). Fuel Cell Development Dept.; Miyahara, A. [Tokyo Gas Company Limited (Japan). Duel Cell R& D Dept.; Veyo, S.E. [Westinghouse Electric Corp., Pittsburgh, PA (United States). Westinghouse Science & Technology Center

1997-12-31T23:59:59.000Z

431

Commercialization of a 2.5kW Utility Interactive Inverter for Distributed Generation  

SciTech Connect

Through this project, Advanced Energy Conversion (AEC) has developed, tested, refined and is preparing to commercialize a 2.5kW utility-interactive inverter system for distributed generation. The inverter technology embodies zero-voltage switching technology that will ultimately yield a system that is smaller, less expensive and more efficient than existing commercial technologies. This program has focused on commercial success through careful synthesis of technology, market-focus and business development. AEC was the primary participant. AEC is utilizing contract manufacturers in the early stages of production, allowing its technical staff to focus on quality control issues and product enhancements. The objective of this project was to bring the AEC inverter technology from its current pre-production state to a commercial product. Federal funds have been used to build and test production-intent inverters, support the implementation of the commercialization plan and bring the product to the point of UL certification.

Torrey, David A.

2006-05-26T23:59:59.000Z

432

Management Of Hanford KW Basin Knockout Pot Sludge As Spent Nuclear Fuel  

SciTech Connect

CH2M HILL Plateau Remediation Company (CHPRC) and AREVA Federal Services, LLC (AFS) have been working collaboratively to develop and deploy technologies to remove, transport, and interim store remote-handled sludge from the 10S-K West Reactor Fuel Storage Basin on the U.S. Department of Energy (DOE) Hanford Site near Richland, WA, USA. Two disposal paths exist for the different types of sludge found in the K West (KW) Basin. One path is to be managed as Spent Nuclear Fuel (SNF) with eventual disposal at an SNF at a yet to be licensed repository. The second path will be disposed as remote-handled transuranic (RH-TRU) waste at the Waste Isolation Pilot Plant (WIPP) in Carlsbad, NM. This paper describes the systems developed and executed by the Knockout Pot (KOP) Disposition Subproject for processing and interim storage of the sludge managed as SNF, (i.e., KOP material).

Raymond, R. E. [CH2M HIll Plateau Remediation Company, Richland, WA (United States); Evans, K. M. [AREVA, Avignon (France)

2012-10-22T23:59:59.000Z

433

Solar concentration of 50,000 achieved with output power approaching 1 kW  

SciTech Connect

The authors have achieved a 50,000 {+-} 3,000 times concentration of sunlight using a unique dielectric nonimaging concentrator in an experiment performed at the National Renewable Energy Laboratory. The scale of the experiment is several times larger than that of previous experiments. Total output power approaching 1 kW passes through a 4.6 mm diameter aperture. An extractor tip is added to the concentrator profile which allows measurement of flux levels using an air calorimeter. This new device has the potential to allow the use of dielectric concentrators at larger scale for thermal electric power generation. The authors report on the implications of this experiment for the future use of dielectric concentrators.

Jenkins, D.; Winston, R.; Bliss, J.; O`Gallagher, J. [Univ. of Chicago, IL (United States); Lewandowski, A.; Bingham, C. [National Renewal Energy Lab., Golden, CO (United States)

1996-08-01T23:59:59.000Z

434

Unlocking the potential for efficiency and demand response through advanced metering  

E-Print Network (OSTI)

energy information Dynamic tariffs Enhanced billing information Societal Applications Rates tailored to market

Levy, Roger; Herter, Karen; Wilson, John

2004-01-01T23:59:59.000Z

435

Technical Review Report for the Mound 1KW Package Safety Analysis Report for Packaging Addendum No. 1, through Revision b  

SciTech Connect

This Technical Review Report (TRR) documents the review, performed by the Lawrence Livermore National Laboratory (LLNL) staff, at the request of the U.S. Department of Energy (DOE), on the 'Mound 1KW Package Safety Analysis Report for Packaging, Addendum No. 1, Revision b', dated May 2007 (Addendum 1). The Mound 1KW Package is certified by DOE Certificate of Compliance (CoC) number USA/9516/B(U)F-85 for the transportation of Type B quantities of plutonium heat source material. The safety analysis of the package is documented in the 'Safety Analysis Report for Packaging (SARP) for the Mound 1KW Package' (i.e., the Mound 1KW SARP, or the SARP). Addendum 1 incorporates a new fueled capsule assembly payload. The following changes have been made to add this payload: (1) The primary containment vessel (PCV) will be of the same design, but will increase in height to 11.16 in.; (2) A new graphite support block will be added to support up to three fueled capsule assemblies per package; (3) The cutting groove height on the secondary containment vessel (SCV) will be heightened to accommodate the taller PCV; and (4) A 3.38 in. high graphite filler block will be placed on top of the PCV. All other packaging features, as described in the Mound 1KW SARP [3], remain unchanged. This report documents the LLNL review of Addendum 1[1]. The specific review for each SARP Chapter is documented herein.

DiSabatino, A; West, M; Hafner, R; Russell, E

2007-10-04T23:59:59.000Z

436

Demand Response Valuation Frameworks Paper  

Science Conference Proceedings (OSTI)

While there is general agreement that demand response (DR) is a valued component in a utility resource plan, there is a lack of consensus regarding how to value DR. Establishing the value of DR is a prerequisite to determining how much and what types of DR should be implemented, to which customers DR should be targeted, and a key determinant that drives the development of economically viable DR consumer technology. Most approaches for quantifying the value of DR focus on changes in utility system revenue requirements based on resource plans with and without DR. This ''utility centric'' approach does not assign any value to DR impacts that lower energy and capacity prices, improve reliability, lower system and network operating costs, produce better air quality, and provide improved customer choice and control. Proper valuation of these benefits requires a different basis for monetization. The review concludes that no single methodology today adequately captures the wide range of benefits and value potentially attributed to DR. To provide a more comprehensive valuation approach, current methods such as the Standard Practice Method (SPM) will most likely have to be supplemented with one or more alternative benefit-valuation approaches. This report provides an updated perspective on the DR valuation framework. It includes an introduction and four chapters that address the key elements of demand response valuation, a comprehensive literature review, and specific research recommendations.

Heffner, Grayson

2009-02-01T23:59:59.000Z

437

Demand Side Bidding. Final Report  

SciTech Connect

This document sets forth the final report for a financial assistance award for the National Association of Regulatory Utility Commissioners (NARUC) to enhance coordination between the building operators and power system operators in terms of demand-side responses to Location Based Marginal Pricing (LBMP). Potential benefits of this project include improved power system reliability, enhanced environmental quality, mitigation of high locational prices within congested areas, and the reduction of market barriers for demand-side market participants. NARUC, led by its Committee on Energy Resources and the Environment (ERE), actively works to promote the development and use of energy efficiency and clean distributive energy policies within the framework of a dynamic regulatory environment. Electric industry restructuring, energy shortages in California, and energy market transformation intensifies the need for reliable information and strategies regarding electric reliability policy and practice. NARUC promotes clean distributive generation and increased energy efficiency in the context of the energy sector restructuring process. NARUC, through ERE's Subcommittee on Energy Efficiency, strives to improve energy efficiency by creating working markets. Market transformation seeks opportunities where small amounts of investment can create sustainable markets for more efficient products, services, and design practices.

Spahn, Andrew

2003-12-31T23:59:59.000Z

438

Definition: Peak Demand | Open Energy Information  

Open Energy Info (EERE)

Peak Demand Peak Demand Jump to: navigation, search Dictionary.png Peak Demand The highest hourly integrated Net Energy For Load within a Balancing Authority Area occurring within a given period (e.g., day, month, season, or year)., The highest instantaneous demand within the Balancing Authority Area.[1] View on Wikipedia Wikipedia Definition Peak demand is used to refer to a historically high point in the sales record of a particular product. In terms of energy use, peak demand describes a period of strong consumer demand. Related Terms Balancing Authority Area, energy, demand, balancing authority, smart grid References ↑ Glossary of Terms Used in Reliability Standards An inli LikeLike UnlikeLike You like this.Sign Up to see what your friends like. ne Glossary Definition Retrieved from

439

Distillate Demand Strong in December 1999  

Gasoline and Diesel Fuel Update (EIA)

5% higher than in the prior year, due mainly to diesel demand growth, since warm weather kept heating oil demand from growing much. Last December, when stocks dropped below...

440

Solar in Demand | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

in Demand Solar in Demand June 15, 2012 - 10:23am Addthis Kyle Travis, left and Jon Jackson, with Lighthouse Solar, install microcrystalline PV modules on top of Kevin Donovan's...

Note: This page contains sample records for the topic "kw billing demand" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Demand Response - Policy | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

over the last 11 years when interest in demand response increased. Demand response is an electricity tariff or program established to motivate changes in electric use by end-use...

442

Energy Basics: Tankless Demand Water Heaters  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

only as needed and without the use of a storage tank. They don't produce the standby energy losses associated with storage water heaters. How Demand Water Heaters Work Demand...

443

Propane Demand by Sector - Energy Information Administration  

U.S. Energy Information Administration (EIA)

In order to understand markets you also have to look at supply and demand. First, demand or who uses propane. For the most part, the major components of propane ...

444

Data:16569441-c535-4b64-a4e3-5878298055c1 | Open Energy Information  

Open Energy Info (EERE)

c535-4b64-a4e3-5878298055c1 c535-4b64-a4e3-5878298055c1 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Douglas, Georgia (Utility Company) Effective date: 2012/01/01 End date if known: Rate name: Large Power Sector: Industrial Description: Current kW & prior 11 months' kW greater than or equal to 500 kW. Source or reference: Rate Binder Kelly 2 ISU Documentation Source Parent: Comments Minimum monthly bill: $100 + ($8.00 * Billing kW) + ECCR + PCA Applicability Demand (kW) Minimum (kW): Maximum (kW): History (months): Energy (kWh) Minimum (kWh): Maximum (kWh): History (months):

445

Travel Behavior and Demand Analysis and Prediction  

E-Print Network (OSTI)

and Demand Analysis and Prediction Konstadinos G. Goulias University of California Santa Barbara, Santa Barbara, CA, USA

Goulias, Konstadinos G

2007-01-01T23:59:59.000Z

446

Forecasting the demand for commercial telecommunications satellites  

Science Conference Proceedings (OSTI)

This paper summarizes the key elements of a forecast methodology for predicting demand for commercial satellite services and the resulting demand for satellite hardware and launches. The paper discusses the characterization of satellite services into more than a dozen applications (including emerging satellite Internet applications) used by Futron Corporation in its forecasts. The paper discusses the relationship between demand for satellite services and demand for satellite hardware

Carissa Bryce Christensen; Carie A. Mullins; Linda A. Williams

2001-01-01T23:59:59.000Z

447

Forecasting Uncertain Hotel Room Demand  

E-Print Network (OSTI)

Economic systems are characterized by increasing uncertainty in their dynamics. This increasing uncertainty is likely to incur bad decisions that can be costly in financial terms. This makes forecasting of uncertain economic variables an instrumental activity in any organization. This paper takes the hotel industry as a practical application of forecasting using the Holt-Winters method. The problem here is to forecast the uncertain demand for rooms at a hotel for each arrival day. Forecasting is part of hotel revenue management system whose objective is to maximize the revenue by making decisions regarding when to make rooms available for customers and at what price. The forecast approach discussed in this paper is based on quantitative models and does not incorporate management expertise. Even though, forecast results are found to be satisfactory for certain days, this is not the case for other arrival days. It is believed that human judgment is important when dealing with ...

Mihir Rajopadhye Mounir; Mounir Ben Ghaliay; Paul P. Wang; Timothy Baker; Craig V. Eister

2001-01-01T23:59:59.000Z

448

Opportunities for Open Automated Demand Response in Wastewater Treatment Facilities in California - Phase II Report. San Luis Rey Wastewater Treatment Plant Case Study  

SciTech Connect

This case study enhances the understanding of open automated demand response opportunities in municipal wastewater treatment facilities. The report summarizes the findings of a 100 day submetering project at the San Luis Rey Wastewater Treatment Plant, a municipal wastewater treatment facility in Oceanside, California. The report reveals that key energy-intensive equipment such as pumps and centrifuges can be targeted for large load reductions. Demand response tests on the effluent pumps resulted a 300 kW load reduction and tests on centrifuges resulted in a 40 kW load reduction. Although tests on the facility?s blowers resulted in peak period load reductions of 78 kW sharp, short-lived increases in the turbidity of the wastewater effluent were experienced within 24 hours of the test. The results of these tests, which were conducted on blowers without variable speed drive capability, would not be acceptable and warrant further study. This study finds that wastewater treatment facilities have significant open automated demand response potential. However, limiting factors to implementing demand response are the reaction of effluent turbidity to reduced aeration load, along with the cogeneration capabilities of municipal facilities, including existing power purchase agreements and utility receptiveness to purchasing electricity from cogeneration facilities.

Thompson, Lisa; Lekov, Alex; McKane, Aimee; Piette, Mary Ann

2010-08-20T23:59:59.000Z

449

Forecasting demand of commodities after natural disasters  

Science Conference Proceedings (OSTI)

Demand forecasting after natural disasters is especially important in emergency management. However, since the time series of commodities demand after natural disasters usually has a great deal of nonlinearity and irregularity, it has poor prediction ... Keywords: ARIMA, Demand forecasting, EMD, Emergency management, Natural disaster

Xiaoyan Xu; Yuqing Qi; Zhongsheng Hua

2010-06-01T23:59:59.000Z

450

Leveraging gamification in demand dispatch systems  

Science Conference Proceedings (OSTI)

Modern demand-side management techniques are an integral part of the envisioned smart grid paradigm. They require an active involvement of the consumer for an optimization of the grid's efficiency and a better utilization of renewable energy sources. ... Keywords: demand response, demand side management, direct load control, gamification, smart grid, sustainability

Benjamin Gnauk; Lars Dannecker; Martin Hahmann

2012-03-01T23:59:59.000Z

451

CALIFORNIA ENERGY DEMAND 20142024 FINAL FORECAST  

E-Print Network (OSTI)

CALIFORNIA ENERGY DEMAND 2014­2024 FINAL FORECAST Volume 1: Statewide Electricity Demand in this report. #12;i ACKNOWLEDGEMENTS The demand forecast is the combined product of the hard work to the contributing authors listed previously, Mohsen Abrishami prepared the commercial sector forecast. Mehrzad

452

CALIFORNIA ENERGY DEMAND 20142024 REVISED FORECAST  

E-Print Network (OSTI)

CALIFORNIA ENERGY DEMAND 2014­2024 REVISED FORECAST Volume 1: Statewide Electricity Demand in this report. #12;i ACKNOWLEDGEMENTS The demand forecast is the combined product of the hard work listed previously, Mohsen Abrishami prepared the commercial sector forecast. Mehrzad Soltani Nia helped

453

REVISED CALIFORNIA ENERGY DEMAND FORECAST 20122022  

E-Print Network (OSTI)

REVISED CALIFORNIA ENERGY DEMAND FORECAST 20122022 Volume 2: Electricity Demand by Utility ACKNOWLEDGEMENTS The staff demand forecast is the combined product of the hard work and expertise of numerous, Mohsen Abrishami prepared the commercial sector forecast. Mehrzad Soltani Nia helped prepare

454

REVISED CALIFORNIA ENERGY DEMAND FORECAST 20122022  

E-Print Network (OSTI)

REVISED CALIFORNIA ENERGY DEMAND FORECAST 20122022 Volume 1: Statewide Electricity Demand in this report. #12;i ACKNOWLEDGEMENTS The staff demand forecast is the combined product of the hard work listed previously, Mohsen Abrishami prepared the commercial sector forecast. Mehrzad Soltani Nia helped

455

FINAL STAFF FORECAST OF 2008 PEAK DEMAND  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION FINAL STAFF FORECAST OF 2008 PEAK DEMAND STAFFREPORT June 2007 CEC-200 of the information in this paper. #12;Abstract This document describes staff's final forecast of 2008 peak demand demand forecasts for the respective territories of the state's three investor-owned utilities (IOUs

456

Ups and downs of demand limiting  

SciTech Connect

Electric power load management by limiting power demand can be used for energy conservation. Methods for affecting demand limiting, reducing peak usage in buildings, particularly usage for heating and ventilating systems, and power pricing to encourage demand limiting are discussed. (LCL)

Pannkoke, T.

1976-12-01T23:59:59.000Z

457

Development and Demonstration of a New Generation High Efficiency 10kW Stationary Fuel Cell System  

SciTech Connect

The overall project objective is to develop and demonstrate a polymer electrolyte membrane fuel cell combined heat and power (PEMFC CHP) system that provides the foundation for commercial, mass produced units which achieve over 40% electrical efficiency (fuel to electric conversion) from 50-100% load, greater than 70% overall efficiency (fuel to electric energy + usable waste heat energy conversion), have the potential to achieve 40,000 hours durability on all major process components, and can be produced in high volumes at under $400/kW (revised to $750/kW per 2011 DOE estimates) capital cost.

Howell, Thomas Russell

2013-04-30T23:59:59.000Z

458

Opportunities for Energy Efficiency and Open Automated Demand Response in Wastewater Treatment Facilities in California -- Phase I Report  

SciTech Connect

This report summarizes the Lawrence Berkeley National Laboratory?s research to date in characterizing energy efficiency and automated demand response opportunities for wastewater treatment facilities in California. The report describes the characteristics of wastewater treatment facilities, the nature of the wastewater stream, energy use and demand, as well as details of the wastewater treatment process. It also discusses control systems and energy efficiency and automated demand response opportunities. In addition, several energy efficiency and load management case studies are provided for wastewater treatment facilities.This study shows that wastewater treatment facilities can be excellent candidates for open automated demand response and that facilities which have implemented energy efficiency measures and have centralized control systems are well-suited to shift or shed electrical loads in response to financial incentives, utility bill savings, and/or opportunities to enhance reliability of service. Control technologies installed for energy efficiency and load management purposes can often be adapted for automated demand response at little additional cost. These improved controls may prepare facilities to be more receptive to open automated demand response due to both increased confidence in the opportunities for controlling energy cost/use and access to the real-time data.

Lekov, Alex; Thompson, Lisa; McKane, Aimee; Song, Katherine; Piette, Mary Ann

2009-04-01T23:59:59.000Z

459

150,000 r/min-1.5 kW PM Efficiency Improvement by Means of Permeance Coefficient Optimization of 150,000-r/min, 1.5-kW PM Motor  

E-Print Network (OSTI)

University of Technology) This paper describes an ultra high-speed permanent-magnet synchronous motor design. Configuration of ultra high-speed PM motor. Core Coil (Winding) Air Permanent Magnet Shaft Stator Air 2 FEM Optimization of 150,000-r/min, 1.5-kW PM Motor Masaru Kano, Student Member, Toshihiko Noguchi, Member (Nagaoka

Fujimoto, Hiroshi

460

Data:C1b84362-b883-44a4-80be-6114f8b80858 | Open Energy Information  

Open Energy Info (EERE)

4362-b883-44a4-80be-6114f8b80858 4362-b883-44a4-80be-6114f8b80858 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Tri-County Elec Member Corp Effective date: 2012/01/01 End date if known: Rate name: Church Demand - Three Phase* Sector: Commercial Description: *Applicable for all churches of the Cooperative who do not qualify for or who do not elect to receive service under other church rate schedules offered by the Cooperative. Determination of Billing Demand: The Billing Demand for any delivery point shall be based upon the highest 30-minute kW measurements during the current billing month and the preceding eleven (11) months. For the billing dates June 1 through September 30 and December 1 through February 28, the Billing Demand shall be the greater of: 1. 100% of the metered demand for the current month, or 2. 75% of the highest metered demand occurring in any previous applicable summer billing dates (June 1 - September 30). For all the billing dates of October 1 through November 30 and March 1 through May 31, the Billing Demand shall be the greater of: 1. 85% of the metered demand for the current month, or 2. 75% of the highest metered demand occurring in any previous applicable summer billing dates (June 1 - September 30). In no case shall the Billing Demand be less than the greater of (1) the minimum Billing Demand specified in the contract for service between the Cooperative and the member, or (2) 15 kW.

Note: This page contains sample records for the topic "kw billing demand" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Data:2a37681e-f5dd-4fcc-8752-abc9b912fbac | Open Energy Information  

Open Energy Info (EERE)

681e-f5dd-4fcc-8752-abc9b912fbac 681e-f5dd-4fcc-8752-abc9b912fbac No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Tri-County Elec Member Corp Effective date: 2012/01/01 End date if known: Rate name: Church Demand - Single Phase* Sector: Commercial Description: *Applicable for all churches of the Cooperative who do not qualify for or who do not elect to receive service under other church rate schedules offered by the Cooperative. Determination of Billing Demand: The Billing Demand for any delivery point shall be based upon the highest 30-minute kW measurements during the current billing month and the preceding eleven (11) months. For the billing dates June 1 through September 30 and December 1 through February 28, the Billing Demand shall be the greater of: 1. 100% of the metered demand for the current month, or 2. 75% of the highest metered demand occurring in any previous applicable summer billing dates (June 1 - September 30). For all the billing dates of October 1 through November 30 and March 1 through May 31, the Billing Demand shall be the greater of: 1. 85% of the metered demand for the current month, or 2. 75% of the highest metered demand occurring in any previous applicable summer billing dates (June 1 - September 30). In no case shall the Billing Demand be less than the greater of (1) the minimum Billing Demand specified in the contract for service between the Cooperative and the member, or (2) 15 kW.

462

Greenhouse Gas Initiatives - Analysis of McCain-Lieberman Bill S.280 ‘The ClimateStewardship and Innovation Act of 2007’ Using the National Energy Modeling System  

E-Print Network (OSTI)

Members of Congress have proposed a number of new aggressive plans for the reduction of greenhouse gases in the United States. Many of these proposals require reductions of 30% below current levels by 2020 and 60-80% reductions from current levels by 2050. While it is clear that achieving these proposed reductions will require major changes in U.S. energy infrastructure and technology implementation; it is only recently that quantitative analyses of the potential implications have become available. One of the critical questions to be addressed is the implications for various energy sources and technologies and the impact on energy prices to end users. This paper reports on the impacts of pending GHG legislation on energy supply, demand, and prices, and the technologies and market mechanisms that are likely to be employed to reduce CO2 emissions. The paper also reports on the results of analysis of GHG bills performed by SAIC using the National Energy Modeling System (NEMS). NEMS is an economy-wide, integrated energy model that analyzes energy supply, conversion, and demand. NEMS is used by the U.S. Energy Information Administration (EIA) to provide US energy market forecasts through 2030, and is the principal tool for the analysis of energy and greenhouse gas policies used by the U.S. government.

Ellsworth, C.

2008-01-01T23:59:59.000Z

463

Design of a 3 kW wind turbine generator with thin airfoil blades  

SciTech Connect

Three blades of a 3 kW prototype wind turbine generator were designed with thin airfoil and a tip speed ratio of 3. The wind turbine has been controlled via two control methods: the variable pitch angle and by regulation of the field current of the generator and examined under real wind conditions. The characteristics of the thin airfoil, called ''Seven arcs thin airfoil'' named so because the airfoil is composed of seven circular arcs, are analyzed with the airfoil design and analysis program XFOIL. The thin airfoil blade is designed and calculated by blade element and momentum theory. The performance characteristics of the machine such as rotational speed, generator output as well as stability for wind speed changes are described. In the case of average wind speeds of 10 m/s and a maximum of 19 m/s, the automatically controlled wind turbine ran safely through rough wind conditions and showed an average generator output of 1105 W and a power coefficient 0.14. (author)

Ameku, Kazumasa; Nagai, Baku M.; Roy, Jitendro Nath [Faculty of Mechanical Engineering, University of the Ryukyus, 1 Senbaru, Nishihara-cho, Okinawa 903-0213 (Japan)

2008-09-15T23:59:59.000Z

464

Frequency-Domain Synthesis Of The Fatigue Load Spectrum For The Nps 100-Kw Wind Turbine  

E-Print Network (OSTI)

* The LIFE2 code is a fatigue/fracture mechanics code that is specialized to the analysis of wind turbine components. Two frequency-domain stress spectra techniques contained in this code are used to analyze the measured frequency loads spectra from the Northern Power Systems 100-kW turbine. Results of the two techniques are compared to cycle counts obtained directly from time series data. These results provide the wind turbine designer with two techniques for determining the cycle-counts from frequency data and illustrate the accuracy that the designer can expect from various cycle-counting techniques. INTRODUCTION The LIFE2 code is a fatigue/fracture mechanics code that is specialized to the analysis of wind turbine components. 1 This code permits the analysis of both time series 2 and frequency domain data. 3 In the case of the former, a "rainflow counting" algorithm is used to convert time series data into a cycle count matrix suitable for fatigue analysis. For the latter,...

Herbert J. Sutherland; Richard M. Osgood

1992-01-01T23:59:59.000Z

465

Development of a 75-kW heat-pipe receiver for solar heat-engines  

DOE Green Energy (OSTI)

A program is now underway to develop commercial power conversion systems that use parabolic dish mirrors in conjunction with Stirling engines to convert solar energy to electric power. In early prototypes, the solar concentrator focused light directly on the heater tubes of the Stirling engine. Liquid-metal heat-pipes are now being developed to transfer energy from the focus of the solar concentrator to the heater tubes of the engine. The dome-shaped heat-pipe receivers are approximately one-half meters in diameter and up to 77-kW of concentrated solar energy is delivered to the absorber surface. Over the past several years, Sandia National Laboratories, through the sponsorship of the Department of Energy, has conducted a major program to explore receiver designs and identify suitable wick materials. A high-flux bench-scale system has been developed to test candidate wick designs, and full-scale systems have been tested on an 11-meter test-bed solar concentrator. Procedures have also been developed in this program to measure the properties of wick materials, and an extensive data-base on wick materials for high temperature heat pipes has been developed. This paper provides an overview of the receiver development program and results from some of the many heat-pipe tests.

Adkins, D.R.; Andraka, C.E.; Moss, T.A.

1995-05-01T23:59:59.000Z

466

FLOATING PRESSURE CONVERSION AND EQUIPMENT UPGRADES OF TWO 3.5KW, 20K, HELIUM REFRIGERATORS  

SciTech Connect

Two helium refrigerators, each rated for 3.5 KW at 20 K, are used at NASA's Johnson Space Center (JSC) in Building No. 32 to provide cryogenic-pumping within two large thermal-vacuum chambers. These refrigerators were originally commissioned in 1996. New changes to the controls of these refrigerators were recently completed. This paper describes some of the control issues that necessitated the controls change-over. It will describe the modifications and the new process control which allows the refrigerators to take advantage of the Ganni Cycle “floating pressure” control technology. The controls philosophy change-over to the floating pressure control technology was the first application on a helium gas refrigeration system. Previous implementations of the floating pressure technology have been on 4 K liquefaction and refrigeration systems, which have stored liquid helium volumes that have level indications used for varying the pressure levels (charge) in the system for capacity modulation. The upgrades have greatly improved the performance, stability, and efficiency of these two refrigerators. The upgrades have also given the operators more information and details about the operational status of the main components (compressors, expanders etc.) of the refrigerators at all operating conditions (i.e. at various loads in the vacuum chambers). The performance data of the two systems, pre and post upgrading are presented.

J. Homan, V. Ganni, A. Sidi-Yekhlef, J. Creel, R. Norton, R. Linza, G. Vargas, J. Lauterbach, J. Urbin, D. Howe

2010-04-01T23:59:59.000Z

467

Test results from the 500 kW direct contact pilot plant at East Mesa  

DOE Green Energy (OSTI)

A 500 kW power plant utilizing direct contact heat exchange (DCHX) between the geothermal brine and the isobutane (IC/sub 4/) working fluid is being operated at the East Mesa test facility. The power plant incorporates a 40-inch-diameter direct-contactor approximately 35 feet tall. The purpose of the pilot plant is to determine the feasibility of large-scale direct-contact heat exchange and power plant operation with the DCHX. The binary cycle offers higher conversion factors (heat energy transformed to electrical energy) than the flashed steam approach for geothermal brines in the 300 to 400/sup 0/F range and preliminary results indicate the DCHX system may have higher performance than the conventional tube-and-shell binary approach. This performance advantage results from the absence of any fouling and the very close pinch temperatures achieved in the DCHX itself. The baseline performance tests for the plant were completed in January 1980. The results of these tests and follow-on testing are covered.

Nichols, K.E.; Olander, R.G.; Lobach, J.L.

1980-09-01T23:59:59.000Z

468

Characterization of Settler Tank, KW Container and KE Container Sludge Simulants  

Science Conference Proceedings (OSTI)

The Sludge Treatment Project (STP), managed by CH2M Hill Plateau Remediation Company (CHPRC) has specified base formulations for non-radioactive sludge simulants for use in the development and testing of equipment for sludge sampling, retrieval, transport, and processing. In general, the simulant formulations are based on the average or design-basis physical and chemical properties obtained by characterizing sludge samples. The simulants include surrogates for uranium metal, uranium oxides (agglomerates and fine particulate), and the predominant chemical phases (iron and aluminum hydroxides, sand). Specific surrogate components were selected to match the nominal particle-size distribution and particle-density data obtained from sludge sample analysis. Under contract to CHPRC, Pacific Northwest National Laboratory (PNNL) has performed physical and rheological characterization of simulants, and the results are reported here. Two base simulant types (dry) were prepared by STP staff at the Maintenance and Storage Facility and received by PNNL in February 2009: Settler Tank Simulant and KW Container Sludge Simulant. A third simulant, KE Container Sludge Simulant was received by PNNL in December 2010. The objectives of this simulant characterization effort were to provide baseline characterization data on simulants being used by STP for process development and equipment testing and provide a high-level comparison of the simulant characteristics to the targets used to formulate the simulants.

Burns, Carolyn A.; Luna, Maria L.; Schmidt, Andrew J.

2011-04-01T23:59:59.000Z

469

Data:343a2bb9-bf22-45e3-a5eb-7a09005ac53f | Open Energy Information  

Open Energy Info (EERE)

bf22-45e3-a5eb-7a09005ac53f bf22-45e3-a5eb-7a09005ac53f No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Anaheim, California (Utility Company) Effective date: 2012/09/12 End date if known: Rate name: General Service -Demand -Schedule GS-1 Sector: Description: Applicable to single and three phase general service including lighting and power. Demand Charges: Minimum, first 15 kW or less of billing demand: $91.20/mo. All excess kW of billing demand: $9.22/kW Source or reference: http://www.anaheim.net/utilities/ElectricRules/SCHD-GS1.pdf Source Parent: Comments Applicability Demand (kW)

470

Measurement and Verification for Demand Response  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Measurement and Verification for Measurement and Verification for Demand Response Prepared for the National Forum on the National Action Plan on Demand Response: Measurement and Verification Working Group AUTHORS: Miriam L. Goldberg & G. Kennedy Agnew-DNV KEMA Energy and Sustainability National Forum of the National Action Plan on Demand Response Measurement and Verification for Demand Response was developed to fulfill part of the Implementation Proposal for The National Action Plan on Demand Response, a report to Congress jointly issued by the U.S. Department of Energy (DOE) and the Federal Energy Regulatory Commission (FERC) in June 2011. Part of that implementation proposal called for a "National Forum" on demand response to be conducted by DOE and FERC. Given that demand response has matured, DOE and FERC decided that a "virtual" project

471

Are they equal yet. [Demand side management  

Science Conference Proceedings (OSTI)

Demand-side management (DSM) is considered an important tool in meeting the load growth of many utilities. Northwest regional and utility resource plans forecast demand-side resources to meet from one-half to two-thirds of additional electrical energy needs over the next 10 years. Numerous sources have stated that barriers, both regulatory and financial, exist to utility acquisition of demand-side resources. Regulatory actions are being implemented in Oregon to make demand-side investments competitive with supply-side investments. In 1989, the Oregon Public Utility Commission (PUC) took two actions regarding demand-side investments. The PUC's Order 89-1700 directed utilities to capitalize demand-side investments to properly match amortization expense with the multiyear benefits provided by DSM. The PUC also began an informal investigation concerning incentives for Oregon's regulated electric utilities to acquire demand-side resources.

Irwin, K.; Phillips-Israel, K.; Busch, E.

1994-05-15T23:59:59.000Z

472

Bill Klemm Y-12 National Security Complex July 10 2012 SB Summit.pdf  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

BILL KLEMM BILL KLEMM SR. VP AND DEPUTY GENERAL MANAGER Y-12 NATIONAL SECURITY COMPLEX Y-12's Missions * Deterrence-produce, maintain and protect essential materials and components for U.S. nuclear arsenal * Naval Reactors-provide highly-enriched uranium for naval fuel * Nuclear Nonproliferation-reduce the threat of terrorism Y-12 Today * FY2011 spending - approximately $1 billion * Approx. 8,000 employees (including 4,600 B&W Y-12, 540 WSI, 80 federal staff and 2,350 subcontractors) * 66% of business partners are small businesses * >$1.5 billion subcontracted to small businesses since 2001 Mentor Protégé, $12.9M Large Business, $181.4M Other Small Business, $154.2M Small Business, 77,463 Large Business, 11,769 Procurement Activity - FY2011 Subcontract Awards

473

Estimating Air Conditioner Loads Using Available Billing and Weather Data: An Exploratory Analysis  

Science Conference Proceedings (OSTI)

In limited testing, an innovative statistical technique for estimating the effects of residential air conditioners on system loads under various weather conditions produced encouraging results. The simple technique, which uses standard utility billing records and readily available weather data, could offer an inexpensive alternative to household monitoring. This report is available only to funders of Program 101A or 101.001. Funders may download this report at http://my.primen.com/Applications/DE/Commun...

1985-10-25T23:59:59.000Z

474

Outpatient physician billing data for age and setting specific syndromic surveillance of influenza-like illnesses  

Science Conference Proceedings (OSTI)

Syndromic surveillance is a novel automated approach to monitoring influenza activity, but there is no consensus regarding the most informative data sources for use within such a system. By comparing physician billing data from Quebec, Canada and hospital ... Keywords: ACIP, ARIMA, Age factors, Ambulatory care, CCF, CDC, ED, Epidemiology, ICD-9, ILI, Immunization programs, Influenza, Human, Medical Records Systems, Computerized, P&I, Population surveillance, RAMQ, RSV, Seasons, Syndrome

Emily H. Chan; Robyn Tamblyn; Katia M. L. Charland; David L. Buckeridge

2011-04-01T23:59:59.000Z

475

Summary Impacts of Modeled Provisions of the 2003 Conference Energy Bill  

Reports and Publications (EIA)

This service report was undertaken at the February 2, 2004, request of Senator John Sununu to perform an assessment of the Conference Energy Bill of 2003. This report summarizes the CEB provisions that can be analyzed using the National Energy Modeling System (NEMS) and have the potential to affect energy consumption, supply, and prices. The impacts are estimated by comparing the projections with the CEB provisions to the AEO2004 Reference Case.

Andy Kydes

2004-02-01T23:59:59.000Z

476

Wind Turbine Generator System Power Performance Test Report for the Gaia-Wind 11-kW Wind Turbine  

DOE Green Energy (OSTI)

This test was conducted as part of the U.S. Department of Energy's (DOE) Independent Testing project. It is a power performance test that the National Renewable Energy Laboratory (NREL) conducted on the Gaia-Wind 11-kW small wind turbine.

Huskey, A.; Bowen, A.; Jager, D.

2009-12-01T23:59:59.000Z

477

160,000-r/min, 2.7-kW Electric Drive of Supercharger for Automobiles  

E-Print Network (OSTI)

,000-r/min, 2.7-kW permanent-magnet synchronous motor drive is discussed and its experimental test-supercharger; centrifugal compressor; ultra high- speed permanent magnet synchronous motor; pseudo-current- source inverter, Nagasaki, Nagasaki 851-0392, Japan Abstract--This paper describes an ultra high-speed permanent- magnet

Fujimoto, Hiroshi

478

220,000-r/min, 2-kW Permanent Magnet Motor Drive for Turbocharger Toshihiko Noguchi, Yosuke Takata *  

E-Print Network (OSTI)

220,000-r/min, 2-kW Permanent Magnet Motor Drive for Turbocharger Toshihiko Noguchi, Yosuke Takata-speed permanent-magnet synchronous motor drive, which is embedded in a turbocharger of an internal permanent magnet. Also, it is indispensable to reduce the motor inductance less than 10 (µH) because dc bus

Fujimoto, Hiroshi

479

1?10 kW Stationary Combined Heat and Power Systems Status and Technical Potential: Independent Review  

DOE Green Energy (OSTI)

This independent review examines the status and technical potential of 1-10 kW stationary combined heat and power fuel cell systems and analyzes the achievability of the DOE cost, efficiency, and durability targets for 2012, 2015, and 2020.

Maru, H. C.; Singhal, S. C.; Stone, C.; Wheeler, D.

2010-11-01T23:59:59.000Z

480

Wind Turbine Generator System Power Performance Test Report for the Gaia-Wind 11-kW Wind Turbine  

SciTech Connect

This test was conducted as part of the U.S. Department of Energy's (DOE) Independent Testing project. It is a power performance test that the National Renewable Energy Laboratory (NREL) conducted on the Gaia-Wind 11-kW small wind turbine.

Huskey, A.; Bowen, A.; Jager, D.

2009-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "kw billing demand" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Assessment of a 200-kW Fuel Cell at the U.S. Army Natick Research Center  

Science Conference Proceedings (OSTI)

The utility industry is showing renewed interest in distributed generation, with a particular interest in fuel cells. This on-going project will provide long-term data on performance and operating characteristics of an ONSI 200-kW phosphoric acid fuel cell at the U.S. Army RD&E Center in Natick, Massachusetts.

1997-10-04T23:59:59.000Z

482

Modeling and Implementation of a 1 kW, Air Cooled HTPEM Fuel Cell in a Hybrid Electrical Vehicle  

E-Print Network (OSTI)

Modeling and Implementation of a 1 kW, Air Cooled HTPEM Fuel Cell in a Hybrid Electrical Vehicle engine vehicles (1). Hybrid systems of many kinds, combining a primary energy source having a high energy://www.ecsdl.org/terms_use.jsp #12;article, a model of a hybrid vehicle, including a HTPEM with lead acid batteries, is de- veloped

Nielsen, Mads Pagh

483

Arkansan Worker Cuts Bills After Auto Job Layoff | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Arkansan Worker Cuts Bills After Auto Job Layoff Arkansan Worker Cuts Bills After Auto Job Layoff Arkansan Worker Cuts Bills After Auto Job Layoff November 24, 2009 - 3:34pm Addthis Joshua DeLung The wind used to howl around the doors and through the attic of Thomas Lee's house. It's an older brick home with poor insulation located just outside the city limits of Tyronza, Ark. The furnace never seemed to kick off in the winter, and keeping his family warm was a constant battle, Thomas says, one that cost him close to $100 extra each month in the winter. Thomas is 51 years old and lives with his wife and two teenage sons. When his two-bedroom home was weatherized in August, the 15-year U.S. Navy veteran experienced the effects of the Recovery Act first-hand when he could really use it. After his 13-year auto manufacturing job, where he was most recently a

484

Arkansan Worker Cuts Bills After Auto Job Layoff | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Arkansan Worker Cuts Bills After Auto Job Layoff Arkansan Worker Cuts Bills After Auto Job Layoff Arkansan Worker Cuts Bills After Auto Job Layoff November 24, 2009 - 3:34pm Addthis Joshua DeLung The wind used to howl around the doors and through the attic of Thomas Lee's house. It's an older brick home with poor insulation located just outside the city limits of Tyronza, Ark. The furnace never seemed to kick off in the winter, and keeping his family warm was a constant battle, Thomas says, one that cost him close to $100 extra each month in the winter. Thomas is 51 years old and lives with his wife and two teenage sons. When his two-bedroom home was weatherized in August, the 15-year U.S. Navy veteran experienced the effects of the Recovery Act first-hand when he could really use it. After his 13-year auto manufacturing job, where he was most recently a

485

Design and Implementation of an Enhanced Power Billing System for Electricity Consumers in Nigeria  

E-Print Network (OSTI)

In Nigeria, electricity consumers are often faced with the problems of inaccurate, irrational and delay in monthly billing due to the drawback in reading pattern and human errors. Thus, it is essential to have an efficient and effective system for such purposes via electronic platform with consideration to proximity. This paper presents the design and functional significance of a web-based application with online capability called Power Billing System (PBS). PBS is a solution system developed with Microsoft Visual Web Development IDE; being an Object Oriented Design tool from Microsoft Visual Studio.net collection and Microsoft Access with SQL query for back-end database. It measures accurately the electric power consumed by residential or commercial buildings which is more economical compared to the electromechanical devices. Individual consumer and the utility companies can directly monitor and control electric power supply billing without engaging the services of meter readers. It displays the sale rate of electrical power per unit and the consumed power per minute. It provides environment to maintain the consumer details right from connection and performance information to the management. It is an Intranet and Internet based software solution that ensures timely

Adegboye Adegboyega; Ayeni A. Gabriel; Alawode J. Ademola; Azeta I. Victor; Kaduna Nigeri

2013-01-01T23:59:59.000Z

486

Study of Energy and Demand Savings on a High Efficiency Hydraulic Pump System with Infinite Turn Down Technology (ITDT)  

E-Print Network (OSTI)

Detailed field measurement and verification of electrical energy (kWh) and demand (kW) savings is conducted on an injection molding machine used in typical plastic manufacturing facility retrofitted with a high efficiency hydraulic pump system. Significant energy usage and demand savings are verified for the retrofitted injection molding machine. The savings are realized by electronically attenuating the torque of a positive displacement pump irrespective of the volumetric flow required by the cycle. With help of a power analyzer, power quality issues are addressed. Some voltage distortion was observed due to the harmonic currents introduced by the control algorithm of the high efficiency hydraulic system. A comparative study of electrical energy and demand savings between an injection molding machine retrofitted with the high efficiency hydraulic pump system or variable frequency drive will also be presented.

Sfeir, R. A.; Kanungo, A.; Liou, S.

2005-01-01T23:59:59.000Z

487

The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California  

E-Print Network (OSTI)

Practices in State Net Metering Policies and InterconnectionThe Economic Cost of Net Metering in Maryland: Who Bears theof Rate Design and Net Metering on the Bill Savings from

Darghouth, Naim R.

2012-01-01T23:59:59.000Z

488

The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California  

E-Print Network (OSTI)

Practices in State Net Metering Policies and InterconnectionThe Economic Cost of Net Metering in Maryland: Who Bears theImpact of Rate Design and Net Metering on the Bill Savings

Darghouth, Naim R.

2012-01-01T23:59:59.000Z

489

Driving Demand for Home Energy Improvements: Motivating residential customers to invest in comprehensive upgrades that eliminate energy waste, avoid high utility bills, and spur the economy  

E-Print Network (OSTI)

Estimated lifecycle cost is 7.1 ¢ per kWh (assuming 44-yearsector. Estimated lifecycle cost is 1.4¢ per kWh (Canadian$;A Estimated lifecycle cost is 3.5¢ per kWh (assuming 10-year

Fuller, Merrian C.

2011-01-01T23:59:59.000Z

490

Driving Demand for Home Energy Improvements: Motivating residential customers to invest in comprehensive upgrades that eliminate energy waste, avoid high utility bills, and spur the economy  

E-Print Network (OSTI)

the process. The utility provided a list of contractors whoUtility staff randomly chose three contractors off the list and

Fuller, Merrian C.

2011-01-01T23:59:59.000Z

491

Driving Demand for Home Energy Improvements: Motivating residential customers to invest in comprehensive upgrades that eliminate energy waste, avoid high utility bills, and spur the economy  

E-Print Network (OSTI)

water heater replacement, air conditioner replacement, solarwater heater replacement, air conditioner replacement, solar

Fuller, Merrian C.

2011-01-01T23:59:59.000Z

492

Driving Demand for Home Energy Improvements: Motivating residential customers to invest in comprehensive upgrades that eliminate energy waste, avoid high utility bills, and spur the economy  

E-Print Network (OSTI)

Long Island Green Homes (LIGH) Marshfield Energy ChallengeLong Island Green Homes (LIGH) Marshfield Energy Challengephrases like “Green Home Remodeling,” “A comfortable, energy

Fuller, Merrian C.

2011-01-01T23:59:59.000Z

493

Driving Demand for Home Energy Improvements: Motivating residential customers to invest in comprehensive upgrades that eliminate energy waste, avoid high utility bills, and spur the economy  

E-Print Network (OSTI)

a Product Developer at Xcel Energy who is working with theby the area‘s two utilities, Xcel Energy and CenterPointstandards. Product Developer at Xcel Energy who is working

Fuller, Merrian C.

2011-01-01T23:59:59.000Z

494

Driving Demand for Home Energy Improvements: Motivating residential customers to invest in comprehensive upgrades that eliminate energy waste, avoid high utility bills, and spur the economy  

E-Print Network (OSTI)

Occupied Homes. ? November 2000. EERE (Energy Efficiency andand Renewable Energy (DOE EERE), Weatherization andBailey and Marion Lunn (DOE EERE) for their support of this

Fuller, Merrian C.

2011-01-01T23:59:59.000Z

495

Driving Demand for Home Energy Improvements: Motivating residential customers to invest in comprehensive upgrades that eliminate energy waste, avoid high utility bills, and spur the economy  

E-Print Network (OSTI)

matters most for changing energy usage in existing homes:use information about energy usage levels to support theirpre-screening for energy usage patterns and pre-existing

Fuller, Merrian C.

2011-01-01T23:59:59.000Z

496

Driving Demand for Home Energy Improvements: Motivating residential customers to invest in comprehensive upgrades that eliminate energy waste, avoid high utility bills, and spur the economy  

E-Print Network (OSTI)

conservation in public housing: a case study of the San Francisco Housing Authority,? Energy and Buildings,

Fuller, Merrian C.

2011-01-01T23:59:59.000Z

497

Current trends in commercial cool storage. Final report. [Use of chilled water and ice storage to reduce demand charges and electric bills; 85 projects  

DOE Green Energy (OSTI)

The objectives of this study were to identify, by means of a phone-and-mail survey, recent installations of off-peak cool storage air conditioning systems in commercial buildings; to monitor new developments; and to indicate trends. This report contains descriptions of over 80 systems installed since 1981, plus findings and conclusions based on site-specific information. Analysis of the findings suggests that storage cooling systems in commercial buildings can, in many cases, offer technical and cost advantages over nonstorage systems. The detailed information should be of value to potential customers and HVAC engineers in making cooling equipment decisions that would be advantageous to customer, utility, and HVAC industry alike. 20 refs.

Hersh, H.N.

1985-07-01T23:59:59.000Z

498

Driving Demand for Home Energy Improvements: Motivating residential customers to invest in comprehensive upgrades that eliminate energy waste, avoid high utility bills, and spur the economy  

E-Print Network (OSTI)

some combination of air sealing, insulation, lightingthose in diagnostics, air sealing, insulation, and othersome combination of air sealing, insulation, lighting

Fuller, Merrian C.

2011-01-01T23:59:59.000Z

499

Driving Demand for Home Energy Improvements: Motivating residential customers to invest in comprehensive upgrades that eliminate energy waste, avoid high utility bills, and spur the economy  

E-Print Network (OSTI)

assessment” instead of “energy audit”. Research Scope Theenergy assessment” instead of “energy audit. ” Marketing and

Fuller, Merrian C.

2011-01-01T23:59:59.000Z

500

Driving Demand for Home Energy Improvements: Motivating residential customers to invest in comprehensive upgrades that eliminate energy waste, avoid high utility bills, and spur the economy  

E-Print Network (OSTI)

have also served as Energy Guides, educating participantsmakes energy savings easier to understand and guides peoplemakes energy savings easier to understand and guides people

Fuller, Merrian C.

2011-01-01T23:59:59.000Z