Powered by Deep Web Technologies
Note: This page contains sample records for the topic "kv remote control" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

0.4 kV remote control (Smart Grid Project) | Open Energy Information  

Open Energy Info (EERE)

4 kV remote control (Smart Grid Project) 4 kV remote control (Smart Grid Project) Jump to: navigation, search Project Name 0.4 kV remote control Country Denmark Coordinates 56.26392°, 9.501785° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":56.26392,"lon":9.501785,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

2

220 kV SSSC device for power flow control (Smart Grid Project) | Open  

Open Energy Info (EERE)

kV SSSC device for power flow control (Smart Grid Project) kV SSSC device for power flow control (Smart Grid Project) Jump to: navigation, search Project Name 220 kV SSSC device for power flow control Country Spain Headquarters Location Catalonia, Spain Coordinates 41.59116°, 1.520862° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":41.59116,"lon":1.520862,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

3

The results of systems tests of the 500 kV busbar controllable shunting reactor in the Tavricheskaya substation  

Science Journals Connector (OSTI)

The results of systems tests of the 500 kV busbar magnetization-controllable shunting reactor (CSR), set up in the Tavricheskaya substation, including measurements of the quality of the...

S. I. Gusev; V. N. Karpov; A. N. Kiselev; V. I. Kochkin

2009-09-01T23:59:59.000Z

4

Underground ventilation remote monitoring and control system  

SciTech Connect (OSTI)

This paper presents the design and installation of an underground ventilation remote monitoring and control system at the Waste Isolation Pilot Plant. This facility is designed to demonstrate safe underground disposal of U.S. defense generated transuranic nuclear waste. To improve the operability of the ventilation system, an underground remote monitoring and control system was designed and installed. The system consists of 15 air velocity sensors and 8 differential pressure sensors strategically located throughout the underground facility providing real-time data regarding the status of the ventilation system. In addition, a control system was installed on the main underground air regulators. The regulator control system gives indication of the regulator position and can be controlled either locally or remotely. The sensor output is displayed locally and at a central surface location through the site-wide Central Monitoring System (CMS). The CMS operator can review all sensor data and can remotely operate the main underground regulators. Furthermore, the Virtual Address Extension (VAX) network allows the ventilation engineer to retrieve real-time ventilation data on his personal computer located in his workstation. This paper describes the types of sensors selected, the installation of the instrumentation, and the initial operation of the remote monitoring system.

Strever, M.T.; Wallace, K.G. Jr.; McDaniel, K.H.

1995-12-31T23:59:59.000Z

5

System and method for controlling remote devices  

DOE Patents [OSTI]

A system and method for controlling remote devices utilizing a radio frequency identification (RFID) tag device having a control circuit adapted to render the tag device, and associated objects, permanently inoperable in response to radio-frequency control signals. The control circuit is configured to receive the control signals that can include an enable signal, and in response thereto enable an associated object, such as a weapon; and in response to a disable signal, to disable the tag itself, or, if desired, to disable the associated weapon or both the device and the weapon. Permanent disabling of the tag can be accomplished by several methods, including, but not limited to, fusing a fusable link, breaking an electrically conductive path, permanently altering the modulation or backscattering characteristics of the antenna circuit, and permanently erasing an associated memory. In this manner, tags in the possession of unauthorized employees can be remotely disabled, and weapons lost on a battlefield can be easily tracked and enabled or disabled automatically or at will.

Carrender, Curtis Lee (Richland, WA); Gilbert, Ronald W. (Benton City, WA); Scott, Jeff W. (Pasco, WA); Clark, David A. (Kennewick, WA)

2006-02-07T23:59:59.000Z

6

The results of systems tests of the 500 kV busbar controllable shunting reactor in the Tavricheskaya substation  

SciTech Connect (OSTI)

The results of systems tests of the 500 kV busbar magnetization-controllable shunting reactor (CSR), set up in the Tavricheskaya substation, including measurements of the quality of the electric power, the harmonic composition of the network currents of the reactor for different values of the reactive power consumed, the determination of the regulating characteristics of the reactor, the speed of response of the shunting reactor in the current and voltage stabilization modes, and also the operation of the reactor under dynamic conditions for different perturbations, are presented. The results obtained are analyzed.

Gusev, S. I. [JSC 'FSK EES' (Russian Federation); Karpov, V. N.; Kiselev, A. N.; Kochkin, V. I. [Scientific-Research Institute of Electric Power Engineering (VNIIE) - Branch of the JSC 'NTTs Elektroenergetiki', (Russian Federation)

2009-09-15T23:59:59.000Z

7

Remote controlled vacuum joint closure mechanism  

DOE Patents [OSTI]

A remotely operable and maintainable vacuum joint closure mechanism for a noncircular aperture is disclosed. The closure mechanism includes an extendible bellows coupled at one end to a noncircular duct and at its other end to a flange assembly having sealed grooves for establishing a high vacuum seal with the abutting surface of a facing flange which includes an aperture forming part of the system to be evacuated. A plurality of generally linear arrangements of pivotally coupled linkages and piston combinations are mounted around the outer surface of the duct and aligned along the length thereof. Each of the piston/linkage assemblies is adapted to engage the flange assembly by means of a respective piston and is further coupled to a remote controlled piston drive shaft to permit each of the linkages positioned on a respective flat outer surface of the duct to simultaneously and uniformly displace a corresponding piston and the flange assembly with which it is in contact along the length of the duct in extending the bellows to provide a high vacuum seal between the movable flange and the facing flange. A plurality of latch mechanisms are also pivotally mounted on the outside of the duct. A first end of each of the latch mechanisms is coupled to a remotely controlled latch control shaft for displacing the latch mechanism about its pivot point. In response to the pivoting displacement of the latch mechanism, a second end thereof is displaced so as to securely engage the facing flange and maintain the high vacuum seal established by the displacement of the flange assembly and extension of the bellows without displacing the entire duct.

Doll, D.W.; Hager, E.R.

1984-02-22T23:59:59.000Z

8

High aspect ratio, remote controlled pumping assembly  

DOE Patents [OSTI]

A miniature dual syringe-type pump assembly which has a high aspect ratio and which is remotely controlled, for use such as in a small diameter penetrometer cone or well packer used in water contamination applications. The pump assembly may be used to supply and remove a reagent to a water contamination sensor, for example, and includes a motor, gearhead and motor encoder assembly for turning a drive screw for an actuator which provides pushing on one syringe and pulling on the other syringe for injecting new reagent and withdrawing used reagent from an associated sensor.

Brown, Steve B. (Livermore, CA); Milanovich, Fred P. (Lafayette, CA)

1995-01-01T23:59:59.000Z

9

Remote control for anode-cathode adjustment  

DOE Patents [OSTI]

An apparatus for remotely adjusting the anode-cathode gap in a pulse power machine has an electric motor located within a hollow cathode inside the vacuum chamber of the pulse power machine. Input information for controlling the motor for adjusting the anode-cathode gap is fed into the apparatus using optical waveguides. The motor, controlled by the input information, drives a worm gear that moves a cathode tip. When the motor drives in one rotational direction, the cathode is moved toward the anode and the size of the anode-cathode gap is diminished. When the motor drives in the other direction, the cathode is moved away from the anode and the size of the anode-cathode gap is increased. The motor is powered by batteries housed in the hollow cathode. The batteries may be rechargeable, and they may be recharged by a photovoltaic cell in combination with an optical waveguide that receives recharging energy from outside the hollow cathode. Alternatively, the anode-cathode gap can be remotely adjusted by a manually-turned handle connected to mechanical linkage which is connected to a jack assembly. The jack assembly converts rotational motion of the handle and mechanical linkage to linear motion of the cathode moving toward or away from the anode.

Roose, Lars D. (Albuquerque, NM)

1991-01-01T23:59:59.000Z

10

Remote monitoring and diagnosis for control of EDM parameters .  

E-Print Network [OSTI]

??This thesis presents the concept of remote (Internet) data acquisition and processing for control of EDM parameters. It incorporates aspects of data analysis while performing (more)

Cilliers, Charl

2008-01-01T23:59:59.000Z

11

Remote-Controlled Home Automation Systems with Different Network Technologies  

E-Print Network [OSTI]

Remote-Controlled Home Automation Systems with Different Network Technologies Armando Roy Delgado into the potential for remote controlled operation of home automation systems. It considers problems, 2002) which certainly requires a careful study before developing any suitable Home Automation System

Grout, Vic

12

Evaluation of first 10-kV optical ETO thyristor operating without any low-voltage control bias  

E-Print Network [OSTI]

unlike any existing ETO (or even IGCT/MTO/GTO devices) is reported at 10 kV using the Silvaco TCAD suite

Mazumder, Sudip K.

13

V-099: Honeywell Multiple Products ActiveX Control Remote Code...  

Broader source: Energy.gov (indexed) [DOE]

9: Honeywell Multiple Products ActiveX Control Remote Code Execution Vulnerability V-099: Honeywell Multiple Products ActiveX Control Remote Code Execution Vulnerability February...

14

Remote control of off-shore oil field production equipment  

E-Print Network [OSTI]

REMOTE CONTROL OF OFF-SHORE OIL FIELD PRODUCTION EQUIPMENT A Thesis Alton W. Sissom 1949 Approve as to style and on n by Cha1rman of omm1ttee REMOTE CONTROL OF OFFSHORE OIL FIELD PRODUCTION EQUIPMENT A Thesis Alton W. Oissom 1949 REMOTE...-Carrier Channel 26 PZNOTE CONTROL OF OFF-SHORE OIL FIELD PRODUCTION K, 'UIPMENT I GENERAL IiPOPPUi TION Since the beginning of the exploitation of the under-sea oil deposits in the Gulf' of qexico, most, of the territory off the shores of Texas and Louisiana...

Sissom, Alton Wayne

2012-06-07T23:59:59.000Z

15

Remote Control of Home Automation Systems with Mobile Devices  

Science Journals Connector (OSTI)

Remote control based on mobile devices as mobile phones or PDAs, is considered more and more useful in many computerised applications. This paper deals with the implementation of functions, based on mobile devic...

Luca Tarrini; Rolando Bianchi Bandinelli

2002-01-01T23:59:59.000Z

16

Automation for on-line remote-control in-situ electron microscopy  

E-Print Network [OSTI]

Pfefferkorn Conference (1996) Automation for On-Line Remote-Pfefferkorn Conference (1996) Automation for On-Line Remote-by incorporating local automation of stage control and

1996-01-01T23:59:59.000Z

17

All Optical Interface for Parallel, Remote, and Spatiotemporal Control of  

E-Print Network [OSTI]

All Optical Interface for Parallel, Remote, and Spatiotemporal Control of Neuronal Activity Sheng and detection of activity in a large number of neurons. Here, we report an all-optical system for achieving optical stimuli through a digital micromirror spatiotemporal light modulator to cells expressing the light

Trauner, Dirk

18

Rate allocation in a remote control structure  

E-Print Network [OSTI]

measuzes. The quantized control problem, in general, has vector sources with weighted distortion measures. The rate allocation scheme of Goodman, must therefore be modified to allow for vector sources. Chapter 3 will specifically address the problem... of rate allocation given vector sources and weighted distortion measures' Equations will be derived for the case when the measurements and controls are assumed independent and when they are dependent. k + k P k (a) k/k-1 (b) Fig. 2. DPCM (a...

Meadow, Charles Joe

1984-01-01T23:59:59.000Z

19

Alternative Fuels Data Center: Students Power Remote-Controlled Cars With  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Students Power Students Power Remote-Controlled Cars With Biodiesel to someone by E-mail Share Alternative Fuels Data Center: Students Power Remote-Controlled Cars With Biodiesel on Facebook Tweet about Alternative Fuels Data Center: Students Power Remote-Controlled Cars With Biodiesel on Twitter Bookmark Alternative Fuels Data Center: Students Power Remote-Controlled Cars With Biodiesel on Google Bookmark Alternative Fuels Data Center: Students Power Remote-Controlled Cars With Biodiesel on Delicious Rank Alternative Fuels Data Center: Students Power Remote-Controlled Cars With Biodiesel on Digg Find More places to share Alternative Fuels Data Center: Students Power Remote-Controlled Cars With Biodiesel on AddThis.com... April 14, 2012 Students Power Remote-Controlled Cars With Biodiesel

20

The Fermilab CMTF cryogenic distribution remote control system  

SciTech Connect (OSTI)

The Cryomodule Test Facility (CMTF) is able to provide the necessary test bed for measuring the performance of Superconducting Radio Frequency (SRF) cavities in a cryomodule (CM). The CMTF have seven 300 KW screw compressors, two liquid helium refrigerators, and two Cryomodule Test Stands (CMTS). CMTS1 is designed for 1.3 GHz cryomodule operating in a pulsed mode (PM) and CMTS2 is for cryomodule operating in Half-Wave (HW) and Continuous Wave (CW) mode. Based on the design requirement, each subsystem has to be far away from each other and be placed in distant locations. Therefore choosing Siemens Process Control System 7-400, DL205 PLC, Synoptic and Fermilab ACNET are the ideal choices for CMTF cryogenic distribution real-time remote control system. This paper presents a method which has been successfully used by many Fermilab distribution cryogenic real-time remote control systems.

Pei, L.; Theilacker, J.; Klebaner, A.; Martinez, A.; Bossert, R. [Fermi National Accelerator Laboratory Batavia, IL, 60510 (United States)

2014-01-29T23:59:59.000Z

Note: This page contains sample records for the topic "kv remote control" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

A Remote Controlled Vehicle with Omnidirectional Sensors Simon Lok, Shree K. Nayar  

E-Print Network [OSTI]

PARAROVER A Remote Controlled Vehicle with Omnidirectional Sensors Simon Lok, Shree K. Nayar.8 DC Power System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 3.2 Electrical

22

U-155: WebCalendar Access Control and File Inclusion Bugs Let Remote Users  

Broader source: Energy.gov (indexed) [DOE]

5: WebCalendar Access Control and File Inclusion Bugs Let 5: WebCalendar Access Control and File Inclusion Bugs Let Remote Users Potentially Execute Arbitrary Code U-155: WebCalendar Access Control and File Inclusion Bugs Let Remote Users Potentially Execute Arbitrary Code April 25, 2012 - 7:00am Addthis PROBLEM: WebCalendar Access Control and File Inclusion Bugs Let Remote Users Potentially Execute Arbitrary Code PLATFORM: 1.2.4 and prior versions ABSTRACT: Two vulnerabilities were reported in WebCalendar. A remote user may be able to execute arbitrary PHP code on the target system. reference links: SecurityTracker Alert ID: 1026966 CVE-2012-1495 CVE-2012-1496 IMPACT ASSESSMENT: Medium Discussion: A remote user can access '/install/index.php' to potentially modify '/includes/settings/' with arbitrary values or PHP code. A remote

23

Solid-State Lighting: Model Specification for Adaptive Control and Remote  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Market-Based Programs Printable Version Share this resource Send a link to Solid-State Lighting: Model Specification for Adaptive Control and Remote Monitoring of LED Roadway Luminaires, V1.0 to someone by E-mail Share Solid-State Lighting: Model Specification for Adaptive Control and Remote Monitoring of LED Roadway Luminaires, V1.0 on Facebook Tweet about Solid-State Lighting: Model Specification for Adaptive Control and Remote Monitoring of LED Roadway Luminaires, V1.0 on Twitter Bookmark Solid-State Lighting: Model Specification for Adaptive Control and Remote Monitoring of LED Roadway Luminaires, V1.0 on Google Bookmark Solid-State Lighting: Model Specification for Adaptive Control and Remote Monitoring of LED Roadway Luminaires, V1.0 on Delicious Rank Solid-State Lighting: Model Specification for Adaptive Control

24

Modulation and SSR tests performed on the BPA 500 kV thyristor controlled series capacitor unit at Slatt substation  

SciTech Connect (OSTI)

Field experience is reported for a thyristor controlled series capacitor (TCSC) recently commissioned at BPA`s Slatt substation. Subsynchronous resonance tests show that TCSC interactions with shaft dynamics of PGE`s Boardman steam generator are well understood and are effectively avoided by normal TCSC valve firing logic. Modulation tests, performed with the Boardman plant off line, show that the TCSC can be a powerful and responsive actuator for swing damping. Security considerations did not permit lightly damped operation of the controlled plant. Close analysis indicates that the TCSC damping contribution, though small, was measurable. The best estimate is that damping for the McNary mode is 7.33% and 8.55%, for the TCSC damper loop open and closed respectively. TCSC testing and monitoring is facilitated by an advanced interactive measurement network representing BPA`s approach to the information requirements of major control systems.

Hauer, J.F. [Pacific Northwest Lab., Richland, WA (United States)] [Pacific Northwest Lab., Richland, WA (United States); Mittelstadt, W.A. [Bonneville Power Administration, Portland, OR (United States)] [Bonneville Power Administration, Portland, OR (United States); Piwko, R.J. [General Electric Co., Schenectady, NY (United States)] [General Electric Co., Schenectady, NY (United States); Damsky, B.L. [Electric Power Research Inst., Palo Alto, CA (United States)] [Electric Power Research Inst., Palo Alto, CA (United States); Eden, J.D. [Portland General Electric, OR (United States)] [Portland General Electric, OR (United States)

1995-07-01T23:59:59.000Z

25

Modulation and SSR tests performed on the BPA 500 kV thyristor controlled series capacitor unit at Slatt substation  

SciTech Connect (OSTI)

Field experience is reported for a thyristor controlled series capacitor (TCSC) recently commissioned at BPA`s Slatt substation. Subsynchronous resonance tests show that TCSC interactions with shaft dynamics of PGE`s Boardman steam generator are well understood and are effectively avoided by normal TCSC valve firing logic. Modulation tests, performed with the Boardman plant off line, show that the TCSC can be a powerful and responsive actuator for swing damping. Security considerations did not permit lightly damped operation of the controlled plant. Close analysis indicates that the TCSC damping contribution, though small, was measurable. The best estimate is that damping for the McNary mode is 7.33% and 8.55%, for the TCSC damper loop open and closed respectively. TCSC testing and monitoring is facilitated by an advanced interactive measurement network representing BPA`s approach to the information requirements of major control systems.

Hauer, J.F. [Pacific Northwest Lab., Richland, WA (United States)] [Pacific Northwest Lab., Richland, WA (United States); Mittelstadt, W.A. [Bonneville Power Administration, Portland, OR (United States)] [Bonneville Power Administration, Portland, OR (United States); Piwko, R.J. [General Electric Co., Schenectady, NY (United States)] [General Electric Co., Schenectady, NY (United States); Damsky, B.L. [Electric Power Research Inst., Palo Alto, CA (United States)] [Electric Power Research Inst., Palo Alto, CA (United States); Eden, J.D. [Portland General Electric, OR (United States)] [Portland General Electric, OR (United States)

1996-05-01T23:59:59.000Z

26

V-076: Cisco Wireless LAN Controller Bugs Let Remote Users Deny Service and  

Broader source: Energy.gov (indexed) [DOE]

6: Cisco Wireless LAN Controller Bugs Let Remote Users Deny 6: Cisco Wireless LAN Controller Bugs Let Remote Users Deny Service and Remote Authenticated Users Modify the Configuration and Execute Arbitrary Code V-076: Cisco Wireless LAN Controller Bugs Let Remote Users Deny Service and Remote Authenticated Users Modify the Configuration and Execute Arbitrary Code January 24, 2013 - 6:00am Addthis PROBLEM: Several vulnerabilities were reported in Cisco Wireless LAN Controller. PLATFORM: The vulnerabilities are reported in: Cisco 2000 Series WLC Cisco 2100 Series WLC Cisco 2500 Series WLC Cisco 4100 Series WLC Cisco 4400 Series WLC Cisco 5500 Series WLC Cisco 7500 Series WLC Cisco 8500 Series WLC Cisco 500 Series Wireless Express Mobility Controllers Cisco Wireless Services Module (Cisco WiSM) Cisco Wireless Services Module version 2 (Cisco WiSM version 2)

27

V-099: Honeywell Multiple Products ActiveX Control Remote Code Execution  

Broader source: Energy.gov (indexed) [DOE]

099: Honeywell Multiple Products ActiveX Control Remote Code 099: Honeywell Multiple Products ActiveX Control Remote Code Execution Vulnerability V-099: Honeywell Multiple Products ActiveX Control Remote Code Execution Vulnerability February 26, 2013 - 12:26am Addthis PROBLEM: Honeywell Multiple Products ActiveX Control Remote Code Execution Vulnerability PLATFORM: Honeywell ComfortPoint Open Manager (CPO-M) Honeywell Enterprise Buildings Integrator (EBI) Honeywell SymmetrE ABSTRACT: A vulnerability has been reported in multiple Honeywell products REFERENCE LINKS: Secunia Advisory SA52389 ICSA-13-053-02 CVE-2013-0108 IMPACT ASSESSMENT: Medium DISCUSSION: The vulnerability is caused due to an unspecified error in the HscRemoteDeploy.dll module. No further information is currently available. Successful exploitation may allow execution of arbitrary code.

28

V-099: Honeywell Multiple Products ActiveX Control Remote Code Execution  

Broader source: Energy.gov (indexed) [DOE]

9: Honeywell Multiple Products ActiveX Control Remote Code 9: Honeywell Multiple Products ActiveX Control Remote Code Execution Vulnerability V-099: Honeywell Multiple Products ActiveX Control Remote Code Execution Vulnerability February 26, 2013 - 12:26am Addthis PROBLEM: Honeywell Multiple Products ActiveX Control Remote Code Execution Vulnerability PLATFORM: Honeywell ComfortPoint Open Manager (CPO-M) Honeywell Enterprise Buildings Integrator (EBI) Honeywell SymmetrE ABSTRACT: A vulnerability has been reported in multiple Honeywell products REFERENCE LINKS: Secunia Advisory SA52389 ICSA-13-053-02 CVE-2013-0108 IMPACT ASSESSMENT: Medium DISCUSSION: The vulnerability is caused due to an unspecified error in the HscRemoteDeploy.dll module. No further information is currently available. Successful exploitation may allow execution of arbitrary code.

29

V-139: Cisco Network Admission Control Input Validation Flaw Lets Remote  

Broader source: Energy.gov (indexed) [DOE]

9: Cisco Network Admission Control Input Validation Flaw Lets 9: Cisco Network Admission Control Input Validation Flaw Lets Remote Users Inject SQL Commands V-139: Cisco Network Admission Control Input Validation Flaw Lets Remote Users Inject SQL Commands April 21, 2013 - 11:50pm Addthis PROBLEM: Cisco Network Admission Control Input Validation Flaw Lets Remote Users Inject SQL Commands PLATFORM: Cisco NAC Manager versions prior to 4.8.3.1 and 4.9.2 ABSTRACT: A vulnerability was reported in Cisco Network Admission Control. REFERENCE LINKS: SecurityTracker Alert ID: 1028451 Cisco Advisory ID: cisco-sa-20130417-nac CVE-2013-1177 IMPACT ASSESSMENT: High DISCUSSION: The Cisco Network Admission Control (NAC) Manager does not properly validate user-supplied input. A remote user can supply a specially crafted parameter value to execute SQL commands on the underlying database.

30

Remote control of ion channels and neurons through magnetic-field heating of nanoparticles  

E-Print Network [OSTI]

Remote control of ion channels and neurons through magnetic-field heating of nanoparticles Heng. Here, we show an approach based on radio-frequency magnetic-field heating of nanoparticles to remotely targeted to specific proteins on the plasma membrane of cells expressing TRPV1, and heated by a radio

Ferkey, Denise

31

T-615: IBM Rational System Architect ActiveBar ActiveX Control Lets Remote  

Broader source: Energy.gov (indexed) [DOE]

5: IBM Rational System Architect ActiveBar ActiveX Control Lets 5: IBM Rational System Architect ActiveBar ActiveX Control Lets Remote Users Execute Arbitrary Code T-615: IBM Rational System Architect ActiveBar ActiveX Control Lets Remote Users Execute Arbitrary Code May 4, 2011 - 7:15am Addthis PROBLEM: A vulnerability was reported in IBM Rational System Architect. A remote user can cause arbitrary code to be executed on the target user's system. PLATFORM: IBM Rational System 11.4 and prior versions ABSTRACT: There is a high risk security vulnerability with the ActiveBar ActiveX controls used by IBM Rational System Architect. reference LINKS: IBM Advisory: 21497689 SecurityTracker Alert ID: 1025464 CVE-2011-1207 Secunia Advisory: SA43399 IMPACT ASSESSMENT: High Discussion: A remote user can create a specially crafted HTML that, when loaded by the

32

Remote control digital photography and metrology are combined to accurately define optical efficiency  

E-Print Network [OSTI]

Remote control digital photography and metrology are combined to accurately define optical, sag from the weight of the heat transfer fluid and the tube itself, or change in the structure over

33

A Structure-Controlled Model For Hot Spring Exploration In Taiwan By Remote  

Open Energy Info (EERE)

Structure-Controlled Model For Hot Spring Exploration In Taiwan By Remote Structure-Controlled Model For Hot Spring Exploration In Taiwan By Remote Sensing Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: A Structure-Controlled Model For Hot Spring Exploration In Taiwan By Remote Sensing Details Activities (0) Areas (0) Regions (0) Abstract: Hot Spring Law of Taiwan was passed in legislative assembly on 3 June 2003. Hot springs would become one of the most important natural resources for recreation purposes. Both public and private sectors will invest large amount of capital in this area in the near future. The value of remote sensing technology is to give a critical tool for observing the landscape to find out mega-scaled geological structures, which may not be able to be found by conventional approaches. The occurrences of the hot

34

Remote controlled tool systems for nuclear sites have subsea applications  

SciTech Connect (OSTI)

Remotely operated underwater tool systems designed to operate in Nuclear Fuel Storage Basins can be applied to deep water, subsea oilfield applications. Spent nuclear fuel rods re stored underwater in large indoor swimming pool-like facilities where the water cover shields the workers from the radiation. This paper describes three specialized tooling systems that were designed and built by Sonsub for work at the Department of Energy`s Hanford site. The Door Seal Tool removed an existing seal system, cleaned a 20 ft. tall, carbon steel, underwater hatch and installed a new stainless steel gasket surface with underwater epoxy. The Concrete Sampling Tool was built to take core samples from the vertical, concrete walls of the basins. The tool has three hydraulic drills with proprietary hollow core drill bits to cut and retrieve the concrete samples. The Rack Saw remotely attached itself to a structure, cut a variety of steel shapes and pipes, and retained the cut pieces for retrieval. All of these systems are remotely operated with onboard video cameras and debris collection systems. The methods and equipment proven in this application are available to refurbish sealing surfaces and to drill or sample concrete in offshore oil field applications.

Bath, B.; Yemington, C. [Sonsub Environmental Services, Houston, TX (United States); Kuhta, B. [Westinghouse Hanford Co., Richland, WA (United States)

1995-10-01T23:59:59.000Z

35

Force Feedback Stabilization for Remote Control of An Assistive Mobile Robot  

E-Print Network [OSTI]

Force Feedback Stabilization for Remote Control of An Assistive Mobile Robot H. Arioui and L. Temzi and Ph. Hoppenot. Abstract-- In this paper, we consider a bilateral control of an assistive mobile robot over communication channels with constant/variable time delays. The mobile robot is used for exploring

Paris-Sud XI, Université de

36

U-211: EMC Celerra/VNX/VNXe Access Control Bug Lets Remote Authenticated  

Broader source: Energy.gov (indexed) [DOE]

11: EMC Celerra/VNX/VNXe Access Control Bug Lets Remote 11: EMC Celerra/VNX/VNXe Access Control Bug Lets Remote Authenticated Users Access Files/Directories U-211: EMC Celerra/VNX/VNXe Access Control Bug Lets Remote Authenticated Users Access Files/Directories July 12, 2012 - 7:00am Addthis PROBLEM: EMC Celerra/VNX/VNXe Access Control Bug Lets Remote Authenticated Users Access Files/Directories PLATFORM: EMC Celerra Network Server versions 6.0.36.4 through 6.0.60.2 EMC VNX versions 7.0.12.0 through 7.0.53.1 EMC VNXe 2.0 (including SP1, SP2, and SP3) EMC VNXe MR1 (including SP1, SP2, SP3, and SP3.1) EMC VNXe MR2 (including SP0.1) ABSTRACT: A vulnerability was reported in EMC Celerra/VNX/VNXe. A remote authenticated user can access files and directories on the target file system. reference LINKS: The Vendor's Advisory

37

BE 400/18 kV Substation Renovation Project  

E-Print Network [OSTI]

The 400/18 kV SPS main substation was designed for the 400 GeV SPS project and was commissioned in 1974. It has been upgraded several times to form the present 400/66/18 kV SPS and LEP transmission power comprising 490 MVA and 240 MVAR installed power. The beginning of the LHC project and the obsolescence of the main elements, and consequently limited reliability, made it necessary to begin a complete renovation program. The new configuration of the substation will integrate the new compensator of reactive power efficiently into the 18 kV pulsed network. In this way the new compensator will facilitate the functioning of the pulsed network with the new loads and it will improve the performance of the electrical substation. The renovation program consists in a global reorganisation of the substation, with the total replacement of the 18 kV power equipment, a set up of new control and protection systems for the 18 kV and 400 kV section and the reconditioning of all the 400 kV equipment.

Vairo, Antonio

2001-01-01T23:59:59.000Z

38

Remote control of an agricultural tractor in SAE field upset tests  

Science Journals Connector (OSTI)

Research by the National Institute for Occupational Safety and Health (NIOSH), Division of Safety Research in Morgantown, West Virginia is addressing the problem of injuries due to agricultural tractor rollovers, and improvements to rollover protective structures (ROPS). As part of this research, the NIOSH, Pittsburgh Research Laboratory modified a Ford model 4600 agricultural tractor for remote control operation, and used this tractor to conduct SAE field upset tests. Modifications to the tractor involved installing a protective framework, electrical actuators for fuel, brake, clutch, and steering controls, and a radio link for remote operation. The tractor has been used to complete over 30 total side and back upset tests, with no failures of the remote control system. These tests have allowed NIOSH researchers to study the performance of currently available ROPS, use this information for the development of improved ROPS designs, and test a NIOSH-developed prototype automatically deploying ROPS.

T.J. Lutz; G.T. Homce

2004-01-01T23:59:59.000Z

39

Nonlinear Adaptive Control of Networked Power Generators with Remote Measurement Units  

E-Print Network [OSTI]

provided by Phasor Measurement Units (PMU). The proposed control system is designed in a robust way illustrate its good behavior, and suggest that the new measurement and data transmission devices can bring Measurement Units (PMU). These devices are far beyond SCADA, and let one envisage the use of real time remote

Paris-Sud XI, Université de

40

Using handhelds for wireless remote control of PCs and appliances  

Science Journals Connector (OSTI)

......upnp.org ). UPnP provides standard protocols for controlling appliances...feedback about state, and defines standard sets of functionality for different...devices. Already, there are standards for devices such as printers...equipment, lighting, and HVAC (heating, venting and air......

Brad A. Myers

2005-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "kv remote control" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

69 kV shunt capacitor bank specification considerations  

SciTech Connect (OSTI)

PSI has standardized on the 69 kv ungrounded star, 7.2 mvar or multiple of the 7.2 mvar shunt capacitor bank for var control. This document defines the considerations to be addressed when specifying a 69 kv ungrounded capacitor bank and for providing suitable protection. The design goal is to provide a bank that is reliable and meets operational requirements at minimum cost with standard components. The bank components will be discussed separately. This paper defines the considerations for specifying capacitor banks to minimize cost, improve reliability and help standardize design. The components making up the bank will be individually discussed with special emphasis on the protection and control.

Fenner, G.E. (PSI Energy, Inc., Plainfield, IN (US))

1992-01-01T23:59:59.000Z

42

Use of Satellite Remote Sensing in Monitoring Saltcedar Control along the Lower Pecos River, USA  

E-Print Network [OSTI]

. In 1999 through 2004, herbicides were sprayed from helicopters along some sections of the river to reduce saltcedar infestation. Here we describe a simple methodology based on satellite remote sensing for monitoring the impact of the saltcedar control... measures. Data from the Landsat 7 Enhanced Thematic Mapper Plus (ETM+) and the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) obtained in 1999 through 2004 over a section of the Pecos near Mentone, Texas were used for the present...

Nagihara, Seiichi; Hart, Charles R.

2007-07-23T23:59:59.000Z

43

Optical Communication System for Remote Monitoring and Adaptive Control of Distributed Ground Sensors Exhibiting Collective Intelligence  

SciTech Connect (OSTI)

Comprehensive management of the battle-space has created new requirements in information management, communication, and interoperability as they effect surveillance and situational awareness. The objective of this proposal is to expand intelligent controls theory to produce a uniquely powerful implementation of distributed ground-based measurement incorporating both local collective behavior, and interoperative global optimization for sensor fusion and mission oversight. By using a layered hierarchal control architecture to orchestrate adaptive reconfiguration of autonomous robotic agents, we can improve overall robustness and functionality in dynamic tactical environments without information bottlenecks. In this concept, each sensor is equipped with a miniaturized optical reflectance modulator which is interactively monitored as a remote transponder using a covert laser communication protocol from a remote mothership or operative. Robot data-sharing at the ground level can be leveraged with global evaluation criteria, including terrain overlays and remote imaging data. Information sharing and distributed intelli- gence opens up a new class of remote-sensing applications in which small single-function autono- mous observers at the local level can collectively optimize and measure large scale ground-level signals. AS the need for coverage and the number of agents grows to improve spatial resolution, cooperative behavior orchestrated by a global situational awareness umbrella will be an essential ingredient to offset increasing bandwidth requirements within the net. A system of the type described in this proposal will be capable of sensitively detecting, tracking, and mapping spatial distributions of measurement signatures which are non-stationary or obscured by clutter and inter- fering obstacles by virtue of adaptive reconfiguration. This methodology could be used, for example, to field an adaptive ground-penetrating radar for detection of underground structures in urban environments and to detect chemical species concentrations in migrating plumes. Given is our research in these areas and a status report of our progress.

Cameron, S.M.; Stantz, K.M.; Trahan, M.W.; Wagner, J.S.

1998-11-01T23:59:59.000Z

44

Test results and initial operating experience for the BPA 500 kV thyristor controlled series capacitor-modulation, SSR and performance monitoring  

SciTech Connect (OSTI)

Field experience is reported for a thyristor controlled series capacitor (TCSC) recently commissioned at BPA`s Slatt substation. Subsynchronous resonance tests show that TCSC interactions with shaft dynamics of PGE`s Boardman steam generator are well understood and are effectively avoided by normal TCSC valve firing logic. Modulation tests, performed with the Boardman plant off line, show that the TCSC can be a powerful and responsive actuator for swing damping. Security considerations did not permit lightly damped operation of the controlled plant. Close analysis indicates that the TCSC damping contribution, though small, was measurable. The best estimate is that damping for the McNary mode is 7.33% and 8.55%, for the TCSC damper loop open and closed respectively. TCSC testing and monitoring is facilitated by an advanced interactive measurement network representing BPA`s approach to the information requirements of major control systems.

Hauer, J.F. [Pacific Northwest Lab., Richland, WA (United States); Mittelstad, W.A. [Bonneville Power Administration, Portland, OR (United States); Piwko, R.J. Sr. [General Electric Co., Schenectady, NY (United States)] [and others

1995-12-31T23:59:59.000Z

45

500-kV Central Ferry Substation ...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Central Ferry Substation in Garfield County, Wash., to BPA's 500-kV Lower Monumental Substation in Walla Walla County, Wash. BPA is currently considering two routing...

46

U-081: McAfee SaaS 'myCIOScn.dll' ActiveX Control Lets Remote Users Execute  

Broader source: Energy.gov (indexed) [DOE]

1: McAfee SaaS 'myCIOScn.dll' ActiveX Control Lets Remote Users 1: McAfee SaaS 'myCIOScn.dll' ActiveX Control Lets Remote Users Execute Arbitrary Code U-081: McAfee SaaS 'myCIOScn.dll' ActiveX Control Lets Remote Users Execute Arbitrary Code January 13, 2012 - 9:15am Addthis PROBLEM: McAfee SaaS 'myCIOScn.dll' ActiveX Control Lets Remote Users Execute Arbitrary Code PLATFORM: McAfee ABSTRACT: A remote user can create HTML that, when loaded by the target user, will execute arbitrary code on the target user's system. reference LINKS: SecurityTracker Alert ID: 1026513 Zero Day Initiative ZDI-12-012 McAfee Threat Intelligence IMPACT ASSESSMENT: High Discussion: This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of McAfee Security-as-a-Service. User interaction is required to exploit this vulnerability in that the target must visit a

47

Multiple node remote messaging  

DOE Patents [OSTI]

A method for passing remote messages in a parallel computer system formed as a network of interconnected compute nodes includes that a first compute node (A) sends a single remote message to a remote second compute node (B) in order to control the remote second compute node (B) to send at least one remote message. The method includes various steps including controlling a DMA engine at first compute node (A) to prepare the single remote message to include a first message descriptor and at least one remote message descriptor for controlling the remote second compute node (B) to send at least one remote message, including putting the first message descriptor into an injection FIFO at the first compute node (A) and sending the single remote message and the at least one remote message descriptor to the second compute node (B).

Blumrich, Matthias A. (Ridgefield, CT); Chen, Dong (Croton on Hudson, NY); Gara, Alan G. (Mount Kisco, NY); Giampapa, Mark E. (Irvington, NY); Heidelberger, Philip (Cortlandt Manor, NY); Ohmacht, Martin (Yorktown Heights, NY); Salapura, Valentina (Chappaqua, NY); Steinmacher-Burow, Burkhard (Esslingen, DE); Vranas, Pavlos (Danville, CA)

2010-08-31T23:59:59.000Z

48

Remote-Controlled Inspection Robot for Nuclear Facilities in Underwater Environment  

SciTech Connect (OSTI)

A remote-controlled inspection robot for nuclear facilities was developed. This is a underwater robot technology combined with inspection and flaw removal technologies. This report will describe the structure and performance of this robot. The inspection robot consists of two parts. The one is driving equipment, and the other is inspection and grinding units. It can swim in the tank, move around the tank wall, and stay on the inspection area. After that it starts inspection and flaw removal with a special grinding wheel. This technology had been developed to inspect some Radioactive Waste (RW) tanks in operating nuclear power plants. There are many RW tanks in these plants, which human workers can be hard to access because of a high level dose. This technology is too useful for inspection works of human-inaccessible areas. And also, in conventional inspection process, some worker go into the tank and set up scaffolding after full drainage and decontamination. It spends too much time for these preparations. If tank inspection and flaw removal can be performed in underwater, the outage period will be reduced. Remote-controlled process can be performed in underwater. This is the great advantage for plant owners. Since 1999 we have been applying this inspection robot to operating nuclear 11 facilities in Japan. (authors)

Yasuhiro Miwa; Syuichi Satoh; Naoya Hirose [Ishikawajima-Harima Heavy Industries Company Ltd., 1 Shin-Nakaharacho, Isogoku, Yokohama 235-8501 (Japan)

2002-07-01T23:59:59.000Z

49

Harrer, A., Malzahn, N., Hoeksema, K. & Hoppe, U. (2005). Learning Design Engines as Remote Control to Learning Support Environments.  

E-Print Network [OSTI]

2005 ISSN: 1365-893X Learning Design Engines as Remote Control to Learning Support Environments Andreas documents) and learning environments. According to its current state, the engine controls the learning, that are mapped to the environments' existing functionality (such as "create new workspace"). Thus the engine

Paris-Sud XI, Université de

50

Remotely controlled sensor apparatus for use in dig-face characterization system  

DOE Patents [OSTI]

A remotely controlled sensor platform apparatus useful in a dig-face characterization system is deployed from a mobile delivery device such as standard heavy construction equipment. The sensor apparatus is designed to stabilize sensors against extraneous motions induced by heavy equipment manipulations or other outside influences, and includes a terrain sensing and sensor elevation control system to maintain the sensors in close ground proximity. The deployed sensor apparatus is particularly useful in collecting data in work environments where human access is difficult due to the presence of hazardous conditions, rough terrain, or other circumstances that prevent efficient data collection by conventional methods. Such work environments include hazardous waste sites, unexploded ordnance sites, or construction sites. Data collection in these environments by utilizing the deployed sensor apparatus is desirable in order to protect human health and safety, or to assist in planning daily operations to increase efficiency.

Josten, Nicholas E. (Idaho Falls, ID); Svoboda, John M. (Idaho Falls, ID)

1999-01-01T23:59:59.000Z

51

Remotely controlled sensor apparatus for use in dig-face characterization system  

DOE Patents [OSTI]

A remotely controlled sensor platform apparatus useful in a dig-face characterization system is deployed from a mobile delivery device such as standard heavy construction equipment. The sensor apparatus is designed to stabilize sensors against extraneous motions induced by heavy equipment manipulations or other outside influences, and includes a terrain sensing and sensor elevation control system to maintain the sensors in close ground proximity. The deployed sensor apparatus is particularly useful in collecting data in work environments where human access is difficult due to the presence of hazardous conditions, rough terrain, or other circumstances that prevent efficient data collection by conventional methods. Such work environments include hazardous waste sites, unexploded ordnance sites, or construction sites. Data collection in these environments by utilizing the deployed sensor apparatus is desirable in order to protect human health and safety, or to assist in planning daily operations to increase efficiency. 13 figs.

Josten, N.E.; Svoboda, J.M.

1999-05-25T23:59:59.000Z

52

Predictable interactive control of experiments in a service-based remote laboratory  

Science Journals Connector (OSTI)

Remote and virtual laboratories are commonly used in electronic engineering and computer science to provide hands-on experience for students. Web services have lately emerged as a standardized interfaces to remote laboratory experiments and simulators. ...

Andreas Rasche; Frank Feinbube; Peter Trger; Bernhard Rabe; Andreas Polze

2008-07-01T23:59:59.000Z

53

Remotely Controlled, Continuous Observations of Infrared Radiance with the CSIRO/ARM Mark II Radiometer at the SGP CART Site  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Remotely Controlled, Continuous Observations of Remotely Controlled, Continuous Observations of Infrared Radiance with the CSIRO/ARM Mark II Radiometer at the SGP CART Site C. M. R. Platt and R. T. Austin Department of Atmospheric Science Colorado State University Fort Collins, Colorado C. M. R. Platt and J. A. Bennett Commonwealth Scientific and Industrial Research Organization Atmospheric Research Aspendale, Victoria, Australia Abstract The Commonwealth Scientific and Industrial Research Organization/Atmospheric Radiation Measurement (CSIRO/ARM) Program Mark II infrared (IR) filter radiometer operated continuously at the Southern Great Plains (SGP) Cloud and Radiation Testbed (CART) site for a period of five weeks. Data of high quality were obtained by remote operation and data transfer with no evidence of spurious

54

Forthcoming in: Ezio Di Nucci & Filippo Santoni de Sio (eds.): Drones and Responsibility: Legal, Philosophical and Socio-Technical Perspectives on the Use of Remotely Controlled Weapons. London  

E-Print Network [OSTI]

, Philosophical and Socio-Technical Perspectives on the Use of Remotely Controlled Weapons. London: Ashgate: Will future lethal autonomous weapon systems (LAWS), or `killer robots', be a threat to humanity the probability of war or other lethal conflict--especially as compared to extant remote-controlled weapons

Wallace, Mark

55

A 25 KV/10A PULSER FOR DRIVING A HIGH-POWER PIERCE ELECTRON GUN  

E-Print Network [OSTI]

A 25 KV/10A PULSER FOR DRIVING A HIGH-POWER PIERCE ELECTRON GUN J. J. Barroso, J. O. Rossi, H-tube pulser to drive a high-power electron gun. The tube includes a 2.0µF/100kV capacitor bank whose discharge is controlled by a tetrode tube connected to the gun cathode. Typical measured operating parameters are 3

56

Design and Analysis of a Region-Wide Remotely Controllable Electrical Lock-Out System  

SciTech Connect (OSTI)

Electric utilities have a main responsibility to protect the lives and safety of their workers when they are working on low-, medium-, and high-voltage power lines and distribution circuits. With the anticipated widespread deployment of smart grids, a secure and highly reliable means of maintaining isolation of customer-owned distributed generation (DG) from the affected distribution circuits during maintenance is necessary to provide a fully de-energized work area, ensure utility personnel safety, and prevent hazards that can lead to accidents such as accidental electrocution from unanticipated power sources. Some circuits are serviced while energized (live line work) while others are de-energized for maintenance. For servicing de-energized circuits and equipment, lock-out tag-out (LOTO) programs provide a verifiable procedure for ensuring that circuit breakers are locked in the off state and tagged to indicate that status to operational personnel so that the lines will be checked for voltage to verify they are de-energized. The de-energized area is isolated from any energized sources, which traditionally are the substations. This procedure works well when all power sources and their interconnections are known armed with this knowledge, utility personnel can determine the appropriate circuits to de-energize for isolating the target line or equipment. However, with customer-owned DG tied into the grid, the risk of inadvertently reenergizing a circuit increases because circuit connections may not be adequately documented and are not under the direct control of the local utility. Thus, the active device may not be properly de-energized or isolated from the work area. Further, a remote means of de-energizing and locking out energized devices provides an opportunity for greatly reduced safety risk to utility personnel compared to manual operations. In this paper, we present a remotely controllable LOTO system that allows individual workers to determine the configuration and status of electrical system circuits and permit them to lock out customer-owned DG devices for safety purposes using a highly secure and ultra-reliable radio signal. The system consists of: (1) individual personal lockout devices, (2) lockout communications and logic module at circuit breakers, which are located at all DG devices, and (3) a database and configuration control process located at the utility operations center. The lockout system is a close permissive, i.e., loss of control power or communications will cause the circuit breaker to open. Once the DG device is tripped open, a visual means will provide confirmation of a loss of voltage and current that verifies the disconnected status of the DG. Further the utility personnel will be able to place their own lock electronically on the system to ensure a lockout functionally. The proposed LOTO system provides enhanced worker safety and protection against unintended energized lines when DG is present. The main approaches and challenges encountered through designing the proposed region-wide LOTO system are discussed in this paper. These approaches include: (1) evaluating the reliability of the proposed approach under N-modular redundancy with voter/spares configurations and (2) conducting a system level risk assessment study using the failure modes and effects analysis (FMEA) technique to identify and rank failure modes by probability of occurrence, probability of detection, and severity of consequences. This ranking allows a cost benefits analysis to be conducted such that dollars and efforts will be applied to the failures that provide greatest incremental gains in system capability (resilience, survivability, security, reliability, availability, etc.) per dollar spent whether capital, operations, or investment. Several simulation scenarios and their results are presented to demonstrate the viability of these approaches.

Olama, Mohammed M [ORNL; Allgood, Glenn O [ORNL; Kuruganti, Phani Teja [ORNL; Howlader, Mostofa [ORNL; Kisner, Roger A [ORNL; Ewing, Paul D [ORNL; McIntyre, Timothy J [ORNL

2012-01-01T23:59:59.000Z

57

Stability of an Adaptive Switched Controller for Power System Oscillation Damping using Remote Synchrophasor Signals  

E-Print Network [OSTI]

operation. II. PMU DATA LATENCY Phasor measurement units (PMUs) are distributed across wide geographical). However, communication of data from remote PMUs can introduce data loss, corruption, and latency. Data loss and corruption can be partially mitigated using data reconstruction methods or state estimation

Hespanha, João Pedro

58

Field Demonstration of a 24-kV Superconducting Cable at Detroit Edison  

SciTech Connect (OSTI)

Customer acceptance of high temperature superconducting (HTS) cable technology requires a substantial field demonstration illustrating both the system's technical capabilities and its suitability for installation and operation within the utility environment. In this project, the world's first underground installation of an HTS cable using existing ductwork, a 120 meter demonstration cable circuit was designed and installed between the 24 kV bus distribution bus and a 120 kV-24 kV transformer at Detroit Edison's Frisbie substation. The system incorporated cables, accessories, a refrigeration system, and control instrumentation. Although the system was never put in operation because of problems with leaks in the cryostat, the project significantly advanced the state-of-the-art in the design and implementation of Warm Dielectric cable systems in substation applications. Lessons learned in this project are already being incorporated in several ongoing demonstration projects.

Kelley, Nathan; Corsaro, Pietro

2004-12-01T23:59:59.000Z

59

Special design and testing aspects of the 345 kV East Fishkill substation  

SciTech Connect (OSTI)

The installation of two 135 MVAR capacitor banks in the 345 kV East Fishkill substation required special design of the grounding system, installation of reactors in series with the capacitor banks, closing resistors in the circuit breakers and special shielding of control cables. This paper describes the design of the substation and the tests performed before commissioning the capacitor banks.

Fogarty, R.P.; Halleran, T.M.; Laskowski, L.M.; Mark, D.A. (Consolidated Edison Co. of New York, Inc., New York, NY (United States))

1992-10-01T23:59:59.000Z

60

A source of reactive power at a 35-kV substation of the Vankor oilfield  

Science Journals Connector (OSTI)

An SRP-35/10/10 source of reactive power based on a magnetically controlled RTMU-10000/35-UHL1-series shunt reactor and a capacitor bank rated at 10 MV A at voltage 35 kV is described in this work. It was put int...

B. I. Bazylev; M. A. Bryantsev; S. V. Dyagileva

2012-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "kv remote control" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

The Study of Substation Automation Remote Communication for Multi-granularity Access Control System  

Science Journals Connector (OSTI)

This paper based on the demands of access control of substation automation system, analyzed two operation objects of ... can fulfill the needs of access control in substation automation.

Lichun Shi; Haimei Xiao

2012-01-01T23:59:59.000Z

62

Vibration Proof Construction of 1000kV Electron Microscope  

Science Journals Connector (OSTI)

......University Press 1970 other ORIGINAL Vibration Proof Construction of 1000kV Electron...with the center of gravity. That is, a vibration proof hanging console was made as a method...protecting a 1000kV Electron Microscope from vibration, and this allowed the whole instrument......

Yoshio SAKITANI; Susumu OZASA

1970-01-01T23:59:59.000Z

63

HEART: heart exercise and remote technologies: A randomized controlled trial study protocol  

Science Journals Connector (OSTI)

This manuscript presents the protocol for a randomized controlled trial of a mHealth exercise-based CR program. Results of this trial will provide much needed information about physical and psychological well-bei...

Ralph Maddison; Robyn Whittaker; Ralph Stewart; Andrew Kerr

2011-05-01T23:59:59.000Z

64

Control of HVAC testbeds: remote access and software tools for cooperative research.  

E-Print Network [OSTI]

?? This thesis describes an object oriented programming software that implements a set of automatic controllers for the management-over-the-cloud of Heating, Venting and Air Conditioning (more)

Montes Torns, Ferran

2013-01-01T23:59:59.000Z

65

U-082: McAfee SaaS 'myCIOScn.dll' ActiveX Control Lets Remote...  

Broader source: Energy.gov (indexed) [DOE]

Lets Remote Users Execute Arbitrary Code January 17, 2012 - 1:00pm Addthis PROBLEM: PHP Null Pointer Dereference in zendstrndup() Lets Local Users Deny Service PLATFORM: PHP...

66

U-177: Lotus Quickr for Domino ActiveX Control Buffer Overflow Lets Remote Users Execute Arbitrary Code  

Broader source: Energy.gov [DOE]

A vulnerability was reported in Lotus Quickr for Domino. A remote user can cause arbitrary code to be executed on the target user's system.

67

Alvey-Fairview No.1, 230 kV Rebuild  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Power Administration is planning to rebuild the Alvey Fairview No. 1, 230kV transmission line, construction is scheduled for 2013 or 2014. The 97.46 mile transmission line...

68

T3: Secure, Scalable, Distributed Data Movement and Remote System Control for Enterprise Level Cyber Security  

SciTech Connect (OSTI)

Enterprise level cyber security requires the deployment, operation, and monitoring of many sensors across geographically dispersed sites. Communicating with the sensors to gather data and control behavior is a challenging task when the number of sensors is rapidly growing. This paper describes the system requirements, design, and implementation of T3, the third generation of our transport software that performs this task. T3 relies on open source software and open Internet standards. Data is encoded in MIME format messages and transported via NNTP, which provides scalability. OpenSSL and public key cryptography are used to secure the data. Robustness and ease of development are increased by defining an internal cryptographic API, implemented by modules in C, Perl, and Python. We are currently using T3 in a production environment. It is freely available to download and use for other projects.

Thomas, Gregory S.; Nickless, William K.; Thiede, David R.; Gorton, Ian; Pitre, Bill J.; Christy, Jason E.; Faultersack, Elizabeth M.; Mauth, Jeffery A.

2009-07-20T23:59:59.000Z

69

Anlise metodolgica para a converso de linhas de distribuio de 34,5 KV para 69 KV.  

E-Print Network [OSTI]

??Este trabalho visa apresentar uma anlise metodolgica para viabilizar a realizao da repotenciao, elevando a classe de tenso de linhas de distribuio de 34,5 kV (more)

Patrick Santos de Oliveira

2011-01-01T23:59:59.000Z

70

ETM (Distribution Network Automation on 10 kV cable line stations) (Smart  

Open Energy Info (EERE)

ETM (Distribution Network Automation on 10 kV cable line stations) (Smart ETM (Distribution Network Automation on 10 kV cable line stations) (Smart Grid Project) Jump to: navigation, search Project Name ETM (Distribution Network Automation on 10 kV cable line stations) Country Hungary Headquarters Location Budapest, Hungary Coordinates 47.498405°, 19.040758° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":47.498405,"lon":19.040758,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

71

KvH Projekt GmbH Co KG | Open Energy Information  

Open Energy Info (EERE)

KvH Projekt GmbH Co KG KvH Projekt GmbH Co KG Jump to: navigation, search Name KvH Projekt GmbH & Co KG Place Hamburg, Germany Zip D-20259 Sector Biomass, Solar, Wind energy Product Project developer in wind, solar, biomass and smart architecture. Coordinates 53.553345°, 9.992455° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":53.553345,"lon":9.992455,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

72

Software Design 2 (Arduino Nano) BodyBody--RemotesRemotes  

E-Print Network [OSTI]

Software Design 2 (Arduino Nano) BodyBody--RemotesRemotes Gesture Based Appliance Control System the room Large wireless range, e.g. 100 m range with 1mW XBees Safely separate the Arduino from input ways to lower cost further Switch to Arduino Mini Light Develop our own wireless modules Jacob

Spletzer, John R.

73

Remote maintenance  

SciTech Connect (OSTI)

A general description is given of the study of maintenance design in reactor designs. The Fusion Experimental Reactor and INTOR-J are discussed in terms of simplicity in remote maintenance design, and a figure shows one of the designs of a torus sector configuration for the Fusion Experimental Reactor. An R-tokamak which is under design is a D-T burning device with a Q less than unity. Technical issues are listed and it is suggested that a long-range plan for fusion remote maintenance should be implemented. A multijoint inspection system and a remote maintenance simulation test model of the divertor module are shown.

Kazawa, Y.; Tachikawa, K.; Tone, T.

1983-12-01T23:59:59.000Z

74

Categorical Exclusion (CX) Determination Proposed Action: Elliot 115kV/43.8kV Transmission Substation Construction and Elliot  

Broader source: Energy.gov (indexed) [DOE]

Elliot 115kV/43.8kV Transmission Substation Construction and Elliot Elliot 115kV/43.8kV Transmission Substation Construction and Elliot 43.8kV Transmission Line. Description of Proposed Action: The Central Power Electric Cooperative (Central Power) is proposing a new substation near Elliot, ND to be owned and operated by Western under Western's Valley City to Forman 115kV transmission line in addition to 8 miles of new 43.8kV transmission line to connect the new substation to Dakota Valley Electric's (a Central Power member) North Milnor substation. Number and Title of Categorical Exclusions Being Applied: 10 CFR 1021.410 Subpart D, Appendix B, B4.l1: Construction of electric power substations ... or modification of existing substations and support facilities. Regulatory Requirements for CX Determination: The DOE Guidelines for Compliance with

75

Survey of Magnetic Fields Near BPA 230-kV and 500-kV Transmission Lines.  

SciTech Connect (OSTI)

The purpose of this study was to characterize typical levels and variability of 60Hz magnetic fields at the centerline and edge of right-of-way of Bonneville Power Administration (BPA) 230-kV and 500-kV transmission lines. This was accomplished by taking magnetic field measurements at over 800 spans in Oregon and Washington. The spans were sampled using a stratified random sampling procedure with region (East vs. West), voltage (230-kV vs 500-kV), and circuit configuration as strata. There were five different circuit configuration groups for each region/voltage category requiring a total of 200 strata. Magnetic field measurements were taken at 13 locations under each span using an EMDEX-C as a survey meter. Additional information recorded for each span included conductor height (at 10 locations), right-of-way width, longitudinal and lateral slope, time of day, vegetation, terrain, weather conditions, temperature, wind speed, span length and presence of other lines in the corridor. 9 refs., 17 figs., 26 tabs.

Perrin, Nancy; Aggarwal, Rajinder Pal; Bracken, T. Daniel

1991-05-20T23:59:59.000Z

76

ETM (Distribution Network Automation on 10 kV cable line stations...  

Open Energy Info (EERE)

ETM (Distribution Network Automation on 10 kV cable line stations) (Smart Grid Project) Jump to: navigation, search Project Name ETM (Distribution Network Automation on 10 kV cable...

77

VOLUME 77, NUMBER 18 P H Y S I C A L R E V I E W L E T T E R S 28 OCTOBER 1996 Nonlinear Control of Remote Unstable States in a Liquid Bridge Convection Experiment  

E-Print Network [OSTI]

VOLUME 77, NUMBER 18 P H Y S I C A L R E V I E W L E T T E R S 28 OCTOBER 1996 Nonlinear Control of Remote Unstable States in a Liquid Bridge Convection Experiment Valery Petrov,* Michael F. Schatz, Kurt A bridge to compute control perturbations which are applied by a thermoelectric element. The algorithm

Texas at Austin. University of

78

Back-to-Back Energization of a 60kV Cable Network -Inrush Currents Phenomenon  

E-Print Network [OSTI]

transmission lines with a rated voltage equal to and below 150kV must be put underground, in order to reduce's energization. Fig. 1. ENV 60kV Network map Fig. 2. Single Line Diagram of the analyzed area The knowledge1 Back-to-Back Energization of a 60kV Cable Network - Inrush Currents Phenomenon F. Faria da Silva

Silva, Filipe Faria Da

79

The effectiveness of an indirect control message in decreasing the depreciative behavior of remote camping location users  

E-Print Network [OSTI]

of human waste on ground surface. According to Cole and Dalle-Molle (1982) the most significant problems include: 1) proliferation of fire sites, 2) the creation of elaborate fire rings, 3) litter, and 4) chopped trees and downed logs. These impacts... when the users first arrived at the site, and an impact data sheet, on which the impacts (e. g. , litter) left behind were quantified (e. g. , weighed). A total of 119 observations were completed. Results showed that the remote camping location users...

Barget, Robert George

2012-06-07T23:59:59.000Z

80

CRYOGENIC SYSTEM FOR A 35 KV/90 MVA SATURATED IRON?CORE SUPERCONDUCTING FAULT CURRENT LIMITER  

Science Journals Connector (OSTI)

A cryogenic system was built as an open system for a 35 kV/90 MVA saturated iron?core superconducting fault current limiter. It consists of an annular cylindrical liquid nitrogen dewar cryogenic pipes sensors valves and a control unit. A HTS dc bias coil was immersed with liquid nitrogen in the dewar. The control circuit constantly monitors the liquid nitrogen level and controls the supply of liquid nitrogen in accordance with the liquid nitrogen level change. Nitrogen vapor was directly released into the environment. Heat loss under different working conditions such as no magnetization current 150 A magnetization current and on?grid condition was measured to evaluate the performance of the system. As compared with no magnetization current of the dc bias coil evaporation of liquid nitrogen increases about 20% under the on?grid condition.

H. Hong; W. Z. Gong; B. Tian; J. Y. Zhang; X. M. Hu; J. Z. Wang; X. Y. Niu; Y. Wang; L. F. Zhang; Y. W. Sun; T. Q. Wu; Y. Xin

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "kv remote control" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Remote-controlled NDA (nondestructive assay) systems for feed and product storage at an automated MOX (mixed oxide) facility  

SciTech Connect (OSTI)

Nondestructive assay (NDA) systems have been developed for use in an automated mixed oxide (MOX) fabrication facility. Unique features have been developed for the NDA systems to accommodate robotic sample handling and remote operation. In addition, the systems have been designed to obtain International Atomic Energy Agency inspection data without the need for an inspector at the facility at the time of the measurements. The equipment is being designed to operate continuously in an unattended mode with data storage for periods of up to one month. The two systems described in this paper include a canister counter for the assay of MOX powder at the input to the facility and a capsule counter for the assay of complete liquid-metal fast breeder reactor fuel assemblies at the output of the plant. The design, performance characteristics, and authentication of the two systems will be described. The data related to reliability, precision, and stability will be presented. 5 refs., 10 figs., 4 tabs.

Menlove, H.O.; Augustson, R.H.; Ohtani, T.; Seya, M.; Takahashi, S.; Abedin-Zadeh, R.; Hassan, B.; Napoli, S.

1989-01-01T23:59:59.000Z

82

Docket No. EO-05-01: Further Notice of 230kV Circuit Planned Outages |  

Broader source: Energy.gov (indexed) [DOE]

Further Notice of 230kV Circuit Planned Further Notice of 230kV Circuit Planned Outages Docket No. EO-05-01: Further Notice of 230kV Circuit Planned Outages Docket No. EO-05-01. Pursuant to the United States Department of Energy Order No. 202-05-03, issued December 20, 2005 directing Mirant Potomac River to generate electricity at Potomac River Generating Station, PEPCO hereby files this Further Notice of 230kV Circuit Planned Outages. Docket No. EO-05-01: Further Notice of 230kV Circuit Planned Outages More Documents & Publications Further Notice of 230kV Circuit Planned Outages Re: Potomac River Generating Station Department of Energy, Case No. EO-05-01: Potomac Electric Power Company (PEPCO) Concerning Planned Outages of the 230 kV circuits Re: Potomac River Generating Station Department of Energy Case No.

83

Further Notice of 230kV Circuit Planned Outages | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Further Notice of 230kV Circuit Planned Outages Further Notice of 230kV Circuit Planned Outages Further Notice of 230kV Circuit Planned Outages Docket No. EO-05-01. Order No. 202-05-03: Pursuant 10 the United States Department of Energy "DOE") Order No. 102-05-3, issued December 20, 2005 ("DOE Potomac River Order''), Pepco hereby files this Further Notice Of 230kV Circuit Planned Outages serving the Potomac River Substation, and through thaI station, the District of Columbia. Further Notice of 230kV Circuit Planned Outages More Documents & Publications Re: Potomac River Generating Station Department of Energy, Case No. EO-05-01: Potomac Electric Power Company (PEPCO) Concerning Planned Outages of the 230 kV circuits Docket No. EO-05-01: Further Notice of 230kV Circuit Planned Outages

84

Further Notice of 230kV Circuit Planned Outages | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Further Notice of 230kV Circuit Planned Outages Further Notice of 230kV Circuit Planned Outages Further Notice of 230kV Circuit Planned Outages Docket No. EO-05-01. Order No. 202-05-03: Pursuant 10 the United States Department of Energy "DOE") Order No. 102-05-3, issued December 20, 2005 ("DOE Potomac River Order''), Pepco hereby files this Further Notice Of 230kV Circuit Planned Outages serving the Potomac River Substation, and through thaI station, the District of Columbia. Further Notice of 230kV Circuit Planned Outages More Documents & Publications Docket No. EO-05-01: Further Notice of 230kV Circuit Planned Outages Re: Potomac River Generating Station Department of Energy, Case No. EO-05-01: Potomac Electric Power Company (PEPCO) Concerning Planned Outages of the 230 kV circuits

85

Detailed design of a 13 kA 13 kV dc solid-state turn-off switch  

SciTech Connect (OSTI)

An experimental facility for the study of electromagnetic effects in the First Wall-Blanket-shield (FWBS) systems of fusion reactors has been constructed at Argonne National Laboratory (ANL). In a test volume of 0.76 m/sup 3/, a vertical, pulsed 5 kG dipole field (B < 320 kGs/sup -1/) is perpendicular to a 10 kG solenoid field. Power supplies of 2.75 MW at 550 V dc and 5.5 MW at 550 V dc and a solid-state switch rated at 13 kA and 13 kV (169 MW) control the pulsed magnetic fields. The total stored energy in the coils is 2.6 MJ. This paper describes the design and construction features of the solid-state switching circuit which turns off a dc of 13 kA in approximately 82 ..mu..s and holds off voltages of < 13 kV.

Praeg, W.F.

1985-01-01T23:59:59.000Z

86

U-240: Apple Remote Desktop Encryption Failure Lets Remote Users...  

Broader source: Energy.gov (indexed) [DOE]

0: Apple Remote Desktop Encryption Failure Lets Remote Users Obtain Potentially Sensitive Information U-240: Apple Remote Desktop Encryption Failure Lets Remote Users Obtain...

87

E-Print Network 3.0 - automated remote environmental Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Collection: Engineering 38 Energy-saving through remote control of a wastewater treatment plant Summary: . Keywords: Activated sludge process, Internet systems, Remote...

88

Flatiron-Erie 115kV transmission line project, Larimer, Weld and Boulder Counties, Colorado. Draft environmental impact statement  

SciTech Connect (OSTI)

Western Area Power Administration (Western) proposes to uprate its existing 115-kV Flatiron-Erie transmission line. The line is located in Larimer, Weld and Boulder Counties, Colorado, and passes through the City of Longmont. The line connects Flatiron Substation and several of the substations supplying Longmont. It is a single circuit 115-kV line, 31.5 miles long, and was built in 1950-51 on a 75-foot wide right-of-way (ROW) using wood H-frame structures. Western proposes to build 27 new structures along the line, to replace or modify 45 of the existing structures and to remote 11 of them. Many of these additions and changes would involve structures that are approximately 5 to 15 feet taller than the existing ones. The existing conductors and ground wires would remain in place. The purpose of these actions would be to allow the power carrying capability of the line to be increased and to replace deteriorating/structural members. Western would be the sole participant in the proposed project. This report gives an analysis of the study area environment and the development of alternative routes. An assessment is presented of the impacts of the primary alternative routes. The environmental consequences of this project are addressed.

Not Available

1993-05-01T23:59:59.000Z

89

High reliability low jitter 80kV pulse generator  

Science Journals Connector (OSTI)

Switching can be considered to be the essence of pulsed power. Time accurate switch/trigger systems with low inductance are useful in many applications. This article describes a unique switch geometry coupled with a low-inductance capacitive energy store. The system provides a fast-rising high voltage pulse into a low impedance load. It can be challenging to generate high voltage (more than 50kilovolts) into impedances less than 10???, from a low voltage control signal with a fast rise time and high temporal accuracy. The required power amplification is large, and is usually accomplished with multiple stages. The multiple stages can adversely affect the temporal accuracy and the reliability of the system. In the present application, a highly reliable and low jitter trigger generator was required for the Z pulsed-power facility [M.?E. Savage, L.?F. Bennett, D.?E. Bliss, W.?T. Clark, R.?S. Coats,J.?M. Elizondo, K.?R. LeChien, H.?C. Harjes, J.?M. Lehr, J.?E. Maenchen, D.?H. McDaniel, M.?F. Pasik, T.?D. Pointon, A.?C. Owen, D.?B. Seidel, D.?L. Smith, B.?S. Stoltzfus, K.?W. Struve, W.?A. Stygar, L.?K. Warne, and J.?R. Woodworth, 2007 IEEE Pulsed Power Conference, Albuquerque, NM (IEEE, Piscataway, NJ, 2007), p.979]. The large investment in each Z experiment demands low prefire probability and low jitter simultaneously. The system described here is based on a 100kV DC-charged high-pressure spark gap, triggered with an ultraviolet laser. The system uses a single optical path for simultaneously triggering two parallel switches, allowing lower inductance and electrode erosion with a simple optical system. Performance of the system includes 6ns output rise time into 5.6???, 550ps one-sigma jitter measured from the 5V trigger to the high voltage output, and misfire probability less than 10-4. The design of the system and some key measurements will be shown in the paper. We will discuss the design goals related to high reliability and low jitter. While reliability is usually important, and is coupled with jitter, reliability is seldom given more than a qualitative analysis (if any at all). We will show how reliability of the system was calculated, and results of a jitter-reliability tradeoff study. We will describe the behavior of sulfur hexafluoride as the insulating gas in the mildly nonuniform field geometry at pressures of 300 to 500kPa. We will show the resistance of the arc channels, and show the performance comparisons with normal two-channel operation, and single channel operation.

M. E. Savage and B. S. Stoltzfus

2009-08-27T23:59:59.000Z

90

Buffalo Flat Service 115-KV Transmission Project : Environmental Assessment.  

SciTech Connect (OSTI)

BPA, in conjunction with Midstate Electric Cooperative (Midstate), proposed to construct two sections of a new 115-kV transmission line in central Oregon: one section from BPA's LaPine Substation to Midstate's Fort Rock Substation (BPA), and the other from Fort Rock Substation to the proposed US Air Force radar transmitter site at Buffalo Flat (Midstate). The proposed line would be a total of about 74 miles long, and of either wood or steel single-pole construction; it would parallel existing corridors and/or roads for much of the distance. 23 refs., 6 figs., 5 tabs.

United States. Bonneville Power Administration.

1987-07-01T23:59:59.000Z

91

The under-machine inspection system consists of a remotely controlled robot. This device is capable of accessing hard-to-reach areas and deal with poor lighting conditions, thus decreasing the risk of injury for the inspection  

E-Print Network [OSTI]

. The system also contains shock absorbers in its wheels to deal with rough surfaces. The clamps used here special types of wheel to reduce vibrations during motion. Furthermore, ball wheels are used in this robot#12;The under-machine inspection system consists of a remotely controlled robot. This device

Koschan, Andreas

92

American Nuclear Society 7th Topical Meeting on Robotics and Remote Systems AN INPUT SHAPING CONTROLLER ENABLING  

E-Print Network [OSTI]

. of Mechanical Engineering Massachusetts Institute of Technology Cambridge, MA Eric Kriikku Savannah River Technology Center Westinghouse Savannah River Company Aiken, SC ABSTRACT A gantry crane at the Savannah River Technology Center was retrofitted with an Input Shaping controller. The controller intercepts the operator

Singhose, William

93

Wild Horse 69-kV transmission line environmental assessment  

SciTech Connect (OSTI)

Hill County Electric Cooperative Inc. (Hill County) proposes to construct and operate a 69-kV transmission line from its North Gildford Substation in Montana north to the Canadian border. A vicinity project area map is enclosed as a figure. TransCanada Power Corporation (TCP), a Canadian power-marketing company, will own and construct the connecting 69-kV line from the international border to Express Pipeline`s pump station at Wild Horse, Alberta. This Environmental Assessment is prepared for the Department of Energy (DOE) as lead federal agency to comply with the requirements of the National Environmental Policy Act (NEPA), as part of DOE`s review and approval process of the applications filed by Hill County for a DOE Presidential Permit and License to Export Electricity to a foreign country. The purpose of the proposed line is to supply electric energy to a crude oil pump station in Canada, owned by Express Pipeline Ltd. (Express). The pipeline would transport Canadian-produced oil from Hardisty, Alberta, Canada, to Caster, Wyoming. The Express Pipeline is scheduled to be constructed in 1996--97 and will supply crude oil to refineries in Wyoming and the midwest.

NONE

1996-12-01T23:59:59.000Z

94

Microsoft Word - Deering Lake-Eckley 115-kV Transmission Line...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Deering Lake-Eckley 115-kV Transmission Line Structure Replacements Yuma County, Colorado 1 A. Brief Description of Proposal: Western Area Power Administration (Western) proposes...

95

EIS-0344: Grand Coulee-Bell 500 kV Transmission Line  

Broader source: Energy.gov [DOE]

This EIS analyzes DOE's proposed action for the construction and operation of the proposed Grand Coulee-Bell 500-kV Transmission Line Project.

96

Mead-Liberty 345-kV Transmission Line Access Road Maintenance...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

2 Mead-Liberty 345-kV Transmission Line Access Road Maintenance and Localized Vegetation Management Maricopa County, Arizona Categorical Exclusion Continuation Sheet Project...

97

Bouse Hills Pumping Plant to Harcuvar 115-kV Transmission Line  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Bouse Hills Pumping Plant to Harcuvar 115-kV Transmission Line Inset Structure Installation La Paz County, Arizona Categorical Exclusion Continuation Sheet Special Conditions 1....

98

Concepts and Tests for the Remote-Controlled Dismantling of the Biological Shield and Form work of the KNK Reactor - 13425  

SciTech Connect (OSTI)

The compact sodium-cooled nuclear reactor facility Karlsruhe (KNK), a prototype Fast Breeder, is currently in an advanced stage of dismantling. Complete dismantling is based on 10 partial licensing steps. In the frame of the 9. decommissioning permit, which is currently ongoing, the dismantling of the biological shield is foreseen. The biological shield consists of heavy reinforced concrete with built-in steel fitments, such as form-work of the reactor tank, pipe sleeves, ventilation channels, and measuring devices. Due to the activation of the inner part of the biological shield, dismantling has to be done remote-controlled. During a comprehensive basic design phase a practical dismantling strategy was developed. Necessary equipment and tools were defined. Preliminary tests revealed that hot wire plasma cutting is the most favorable cutting technology due to the geometrical boundary conditions, the varying distance between cutter and material, and the heavy concrete behind the steel form-work. The cutting devices will be operated remotely via a carrier system with an industrial manipulator. The carrier system has expandable claws to adjust to the varying diameter of the reactor shaft during dismantling progress. For design approval of this prototype development, interaction between manipulator and hot wire plasma cutting was tested in a real configuration. For the demolition of the concrete structure, an excavator with appropriate tools, such as a hydraulic hammer, was selected. Other mechanical cutting devices, such as a grinder or rope saw, were eliminated because of concrete containing steel spheres added to increase the shielding factor of the heavy concrete. Dismantling of the biological shield will be done in a ring-wise manner due to static reasons. During the demolition process, the excavator is positioned on its tripod in three concrete recesses made prior to the dismantling of the separate concrete rings. The excavator and the manipulator carrier system will be operated alternately. Main boundary condition for all the newly designed equipment is the decommissioning housing of limited space within the reactor building containment. To allow for a continuous removal of the concrete rubble, an additional opening on the lowest level of the reactor shaft will be made. All equipment and the interaction of the tools have to be tested before use in the controlled area. Therefore a full-scale model of the biological shield will be provided in a mock-up. The tests will be performed in early 2014. The dismantling of the biological shield is scheduled for 2015. (authors)

Neff, Sylvia; Graf, Anja; Petrick, Holger; Rothschmitt, Stefan [WAK Rueckbau- und Entsorgungs- GmbH, P.O.Box 12 63, 76339 Eggenstein- Leopoldshafen (Germany)] [WAK Rueckbau- und Entsorgungs- GmbH, P.O.Box 12 63, 76339 Eggenstein- Leopoldshafen (Germany); Klute, Stefan [Siempelkamp Nukleartechnik GmbH, Am Taubenfeld 25/1, 69123 Heidelberg (Germany)] [Siempelkamp Nukleartechnik GmbH, Am Taubenfeld 25/1, 69123 Heidelberg (Germany); Stanke, Dieter [Siempelkamp NIS Ingenieurgesellschaft mbH, Industriestrasse 13, 63755 Alzenau (Germany)] [Siempelkamp NIS Ingenieurgesellschaft mbH, Industriestrasse 13, 63755 Alzenau (Germany)

2013-07-01T23:59:59.000Z

99

Dyke quality assessment by remote sensing  

E-Print Network [OSTI]

1 RSDYK Dyke quality assessment by remote sensing and geological information Robert Hack Flood Solutions for smart flood control 15 Oct 2009 2Reeuwijk - Hack #12;2 RSDYKRSDYK Quality assessment of dykes from remote sensing in combination with l i l k l dgeological knowledge 15 Oct 2009 3Reeuwijk - Hack

Hack, Robert

100

Notification of Planned 230kV Outage at Potomac River Generating Station |  

Broader source: Energy.gov (indexed) [DOE]

Notification of Planned 230kV Outage at Potomac River Generating Notification of Planned 230kV Outage at Potomac River Generating Station Notification of Planned 230kV Outage at Potomac River Generating Station Docket No. EO-05-01. In accordance with DOE Order No. 202-05-03 Pepco is required to provide notification of any and all 230kV planned outages at Potomac River Generating Station. On Tuesday February 20, 2007 Potomac Electric Power Company (Pepco) will be taking a planned outage on the 23106 high voltage circuit between the Palmer's Corner Substation and the Potomac River Generating Station. Notification of Planned 230kV Outage at Potomac River Generating Station More Documents & Publications Re: Potomac River Generating Station Department of Energy Case No. EO-05-01: Advanced Notice of Power Outages. Special Environmental Analysis For Actions Taken under U.S. Department of

Note: This page contains sample records for the topic "kv remote control" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Remote Environmental Monitoring System CRADA  

SciTech Connect (OSTI)

The goal of the project was to develop a wireless communications system, including communications, command, and control software, to remotely monitor the environmental state of a process or facility. Proof of performance would be tested and evaluated with a prototype demonstration in a functioning facility. AR Designs' participation provided access to software resources and products that enable network communications for real-time embedded systems to access remote workstation services such as Graphical User Interface (GUI), file I/O, Events, Video, Audio, etc. in a standardized manner. This industrial partner further provided knowledge and links with applications and current industry practices. FM and T's responsibility was primarily in hardware development in areas such as advanced sensors, wireless radios, communication interfaces, and monitoring and analysis of sensor data. This role included a capability to design, fabricate, and test prototypes and to provide a demonstration environment to test a proposed remote sensing system. A summary of technical accomplishments is given.

Hensley, R.D.

2000-03-30T23:59:59.000Z

102

T-536: Cisco ASA Multiple Flaws Let Remote Users Deny Service...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

36: Cisco ASA Multiple Flaws Let Remote Users Deny Service and Bypass Security Controls T-536: Cisco ASA Multiple Flaws Let Remote Users Deny Service and Bypass Security Controls...

103

E-Print Network 3.0 - automated remote plant Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Page: << < 1 2 3 4 5 > >> 1 Energy-saving through remote control of a wastewater treatment plant Summary: Energy-saving through remote control of a wastewater treatment plant...

104

EA-1679: Grand Coulee's Third Powerplant 500-kV Transmission Line  

Broader source: Energy.gov (indexed) [DOE]

79: Grand Coulee's Third Powerplant 500-kV Transmission Line 79: Grand Coulee's Third Powerplant 500-kV Transmission Line Replacement Project, Grant and Okanogon Counties, Washington EA-1679: Grand Coulee's Third Powerplant 500-kV Transmission Line Replacement Project, Grant and Okanogon Counties, Washington Summary This EA evaluates potential environmental impacts from the construction and operation of six new 500-kV overhead transmission lines to replace six existing underground lines at Grand Coulee Dam. DOE's Bonneville Power Administration (BPA), a cooperating agency, was asked by the U. S. Department of the Interior's Bureau of Reclamation to design and construct the proposed new transmission lines. A Finding of No Significant Impact was issued by BPA in December 2011. BPA website: http://efw.bpa.gov/environmental_services/Document_Library/Grand_Coulee/

105

EA-1665: Davis-Kingman 69-kV Transmission Line Rebuild Project, Arizona |  

Broader source: Energy.gov (indexed) [DOE]

65: Davis-Kingman 69-kV Transmission Line Rebuild Project, 65: Davis-Kingman 69-kV Transmission Line Rebuild Project, Arizona EA-1665: Davis-Kingman 69-kV Transmission Line Rebuild Project, Arizona Overview Western plans to rebuild a 26.6-mile-long portion of the existing 27.3-mile-long Davis-Kingman Tap 69-kV Transmission Line within the existing ROW in order to improve the reliability of the transmission service. The line has been in service well beyond its projected service life, customer load on the line has increased considerably over the years, and reliability has decreased due to natural aging, extreme weather exposure, vandalism, and lightning strikes. The western-most 0.7 mile of the existing line was rebuilt as part of the Davis Dam Switchyard in 2010. Public Comment Opportunities No public comment opportunities available at this time.

106

150-kV, 80-A SOLID STATE POWER SUPPLY FOR NEUTRAL BEAM INJECTION  

E-Print Network [OSTI]

a zero failure rate. That SCR's may be connected in series120 kV operating systems. That a SCR switched capacitor bank21 Franck, J. V. , et al. , "An SCR Sedes Switch and Impulse

Owren, H.

2011-01-01T23:59:59.000Z

107

ZigBee Performance in 400 KV Air Insulated Power Substation  

Science Journals Connector (OSTI)

An experimental assessment of the impact of the electromagnetic environment of a 400kV substation on the performance of ZigBee equipment is ... the performance of ZigBee equipment deployed in the substation with...

Qingshan Shan; I A Glover; P J Moore

2010-01-01T23:59:59.000Z

108

Development of a 220kV/300MVA superconductive fault current limiter  

Science Journals Connector (OSTI)

After we developed a saturated iron core type 35kV/90MVA superconductive fault current limiter and installed the device in a transmission network at Puji substation of China Southern Power Grid for live-grid operation in 2007, we continued our efforts in advancing this technology. A 220kV/300MVA device has been designed, manufactured and factory tested. This device differs from the 35kV device in its form of electrical insulation even though the two devices have the same working principle and similar core structure. Improvements in the dc magnetization circuit and the cryogenic system were also achieved. This 220kV/300MVA superconductive fault current limiter has been installed and has passed all field tests at Shigezhuang substation in Tianjin, China. Trial operation is underway. This paper introduces the major design parameters, key functional specifications and some testing results of the device.

Y Xin; W Z Gong; H Hong; Y Q Gao; X Y Niu; J Y Zhang; Y W Sun; A L Ren; H Z Wang; L F Zhang; Q Li; Z Q Wei; L Z Wang; J B Cui; G J Niu; Z Q Xiong

2012-01-01T23:59:59.000Z

109

ESS 2012 Peer Review - 6.5 kV Silicon Carbide Half-Bridge Power...  

Broader source: Energy.gov (indexed) [DOE]

a 5 kV DC-Link voltage which will greatly impact Storage Systems by reducing costs of power conversion stages Impact current system designs as well as create a platform for...

110

Grounding of a 230 kV Transmission line over a Limestone Ridge.  

E-Print Network [OSTI]

?? This thesis is a case study of a 230 kV transmission line in Lao P.D.R. Grounding of electrical systems is essential for safety and (more)

Grubbstrm, Emma

2011-01-01T23:59:59.000Z

111

Bonneville Power Administration Grand Coulee-Bell 500-kV Transmission Line Project Record of Decision  

Broader source: Energy.gov (indexed) [DOE]

Grand Coulee-Bell 500-kV Transmission Line Project Grand Coulee-Bell 500-kV Transmission Line Project Record of Decision Decision The Bonneville Power Administration (BPA) has decided to construct the proposed Grand Coulee-Bell 500-kV Transmission Line Project in Douglas, Grant, Lincoln, and Spokane Counties, Washington. BPA has decided to implement the proposed action identified in the Grand Coulee-Bell 500-kV Transmission Line Project Final Environmental Impact Statement (DOE/EIS-0344, December 2002). The proposed action consists of constructing a new 500- kilovolt (kV) transmission line between the Bureau of Reclamation's (BOR) Grand Coulee 500- kV Switchyard near Grand Coulee, Washington, and BPA's Bell Substation near Spokane, a distance of 84 miles. The proposed action involves removing an existing 115-kV transmission

112

SCADA architecture with mobile remote components  

Science Journals Connector (OSTI)

With the advent of new technologies, the demand of connecting IT systems to the Internet is increasing. This is also the case for Control systems specifically SCADA (Supervisory Control and Data Acquisition) systems. Traditional SCADA systems are connected ... Keywords: SCADA, control systems, mobility, remote components

Tai-Hoon Kim

2010-08-01T23:59:59.000Z

113

Architecture for SCADA with mobile remote components  

Science Journals Connector (OSTI)

With the advent of new technologies, the demand of connecting IT systems to the Internet is increasing. This is also the case for Control systems specifically SCADA (Supervisory Control And Data Acquisition) systems. Traditional SCADA systems are connected ... Keywords: SCADA, control systems, mobility, remote components

Rosslin John Robles; Tai-Hoon Kim

2010-05-01T23:59:59.000Z

114

Variability in Springtime Thaw in the Terrestrial High Latitudes: Monitoring a Major Control on the Biospheric Assimilation of Atmospheric CO2 with Spaceborne Microwave Remote Sensing  

Science Journals Connector (OSTI)

Evidence is presented from the satellite microwave remote sensing record that the timing of seasonal thawing and subsequent initiation of the growing season in early spring has advanced by approximately 8 days from 1988 to 2001 for the pan-Arctic ...

Kyle C. McDonald; John S. Kimball; Eni Njoku; Reiner Zimmermann; Maosheng Zhao

2004-12-01T23:59:59.000Z

115

EMI (electromagnetic interference) potential of proposed 115KV line near B-691  

SciTech Connect (OSTI)

The Laser Operated Diamond Turning Machine (LODTM) is housed in Building 691. This facility contains electronic measurement and control systems which could be susceptible to interfering electromagnetic interference (EMI) generated by sources external to B-691. In particular, concern has been expressed that such harmful EMI signals could be produced by the proposed WAPA 115KV feeder line which would be routed approximately 30 feet from the East side of the facility. Also, there has been some concern expressed about the effects of the resulting electromagnetic (EM) fields on personnel in the proximity of the power line. Since it is necessary to measure the EM fields to ascertain if a hazard does indeed exist, and since we in ERD have been performing such field measurements for many years, we were contacted to determine the field levels from the line that might be expected inside and close to B-691. This report describes our approach, equipment and calibration procedures, analysis techniques used, results, and suggestions for future work in related areas. 9 refs., 41 figs.

Latorre, V.R.; Wythe, D.M.

1989-07-27T23:59:59.000Z

116

Marys Lake 69/115-kV transmission line upgrade and substation expansion projects  

SciTech Connect (OSTI)

Western Area Power Administration (Western) and the Platte River Power Authority (Platte River) propose to upgrade portions of the existing electric transmission and substation system that serves the Town of Estes Park, Colorado. The existing transmission lines between the Estes Power Plant Switchyard and the Marys Lake Substation include a 115,000 volt (115-kV) line and 69,000 volt (69-kV) line. Approximately one mile is a double-circuit 115/69-kV line on steel lattice structures, and approximately two miles consists of separate single-circuit 115-kV and a 69-kV lines, constructed on wood H-Frame structures. Both lines were constructed in 1951 by the US Bureau of Reclamation. The existing transmission lines are on rights-of-way (ROW) that vary from 75 feet to 120 feet and are owned by Western. There are 48 landowners adjacent to the existing ROW. All of the houses were built adjacent to the existing ROW after the transmission lines were constructed. Upgrading the existing 69-kV transmission line between the Marys Lake Substation and the Estes Power Plant Switchyard to 115-kV and expanding the Marys Lake Substation was identified as the most effective way in which to improve electric service to Estes Park. The primary purpose and need of the proposed project is to improve the reliability of electric service to the Town of Estes Park. Lack of reliability has been a historical concern, and reliability will always be less than desired until physical improvements are made to the electrical facilities serving Estes Park.

NONE

1996-05-01T23:59:59.000Z

117

14kV single-phase superconducting fault current limiter based on YBCO films  

Science Journals Connector (OSTI)

We present the fabrication and short circuit test results of a 14kV single-phase resistive superconducting fault current limiter (SFCL) based on \\{YBa2Cu3O7\\} (YBCO) films. Individual components were processed using the 4? YBCO films and have the rated voltage and current of 600V and 35A at 77K, respectively. Twenty four components, eight components in series and three lines in parallel, make a module having the rated voltage and current of 4.8kV and 105A, respectively. Three modules were assembled in series to produce the SFCL working at 77K, a 14kV single-phase machine for the 22.9kV YY grid. short circuit tests were successfully conducted in an accredited test facility with the maximum fault currents up to 14.1kAP. All components quenched together upon faults and shared the rated voltage evenly without any supplementary device between the modules. This proves that the SFCL based on YBCO films may not only work reliably at 22.9kV, but also provide technical feasibility for higher voltage application including the transmission grids.

J. Sim; K.B. Park; H.R. Kim; J.S. Kang; B.W. Lee; H.M. Kim; I.S. Oh; O.B. Hyun

2007-01-01T23:59:59.000Z

118

Remote Systems Design & Deployment  

SciTech Connect (OSTI)

The Pacific Northwest National Laboratory (PNNL) was tasked by Washington River Protection Solutions, LLC (WRPS) to provide information and lessons learned relating to the design, development and deployment of remote systems, particularly remote arm/manipulator systems. This report reflects PNNLs experience with remote systems and lays out the most important activities that need to be completed to successfully design, build, deploy and operate remote systems in radioactive and chemically contaminated environments. It also contains lessons learned from PNNLs work experiences, and the work of others in the national laboratory complex.

Bailey, Sharon A.; Baker, Carl P.; Valdez, Patrick LJ

2009-08-28T23:59:59.000Z

119

EIS-0450: TransWest Express 600 kV Direct Current Transmission Project in  

Broader source: Energy.gov (indexed) [DOE]

0: TransWest Express 600 kV Direct Current Transmission 0: TransWest Express 600 kV Direct Current Transmission Project in Wyoming, Colorado, Utah, and Nevada EIS-0450: TransWest Express 600 kV Direct Current Transmission Project in Wyoming, Colorado, Utah, and Nevada Summary This EIS, being prepared jointly by DOE's Western Area Power Administration and the Department of the Interior's Bureau of Land Management (Wyoming State Office), evaluates the environmental impacts of granting a right-of-way for the TransWest Express 600-kilovolt Direct Current Transmission Project and amending a land use plan. The project consists of an overhead transmission line that would extend approximately 725 miles from south-central Wyoming, through Colorado and Utah. Western proposes to be a joint owner of the project. Public Comment Opportunities

120

Microsoft Word - CX-Alvey 500 kV Fencing_WEB.doc  

Broader source: Energy.gov (indexed) [DOE]

3, 2010 3, 2010 REPLY TO ATTN OF: KEPR-4 SUBJECT: Environmental Clearance Memorandum Hamid Habibi Project Manager - TESF-CSB Proposed Action: Replace existing posts and fencing around Alvey Substation 500-kV switch yard. PP&A Project No.: 1 632 Budget Information: Work Order: 00250208 Task: 3 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.11 Installation of fencing, including that for border marking that will not adversely affect wildlife movements or surface water flow. Location: The proposed project is located in Lane County, Oregon at the Bonneville Power Administration (BPA) Alvey substation around the 500-kV switch yard. Proposed by: BPA Description of the Proposed Action: The project involves replacement of the existing fence and fence posts for the 500-kV yard at the

Note: This page contains sample records for the topic "kv remote control" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Design studies for the Mead-Phoenix 500 kV AC transmission project  

SciTech Connect (OSTI)

The Mead-Phoenix 500 kV ac line is 243 miles long and runs parallel to the existing Mead-Liberty 345 kV line. This line is planned for 70% series and 70% shunt compensation; it also incorporates the first application of a 50 kV phase shifting transformer that enables a 1,300 MW transmission capacity. This paper presents the design studies that were undertaken in arriving at the equipment ratings and insulation levels that lead to the equipment specifications. The shunt reactor switching requirements utilizing MOV across the breaker, line switching with line connected arresters and the breaker transient recovery voltage are also dealt with in the paper.

Thallam, R.S.; Lundquist, T.G.; Gerlach, D.W. [Salt River Project, Phoenix, AZ (United States)] [Salt River Project, Phoenix, AZ (United States); Atmuri, S.R. [Teshmont Consultants Inc., Winnipeg, Manitoba (Canada)] [Teshmont Consultants Inc., Winnipeg, Manitoba (Canada); Selin, D.A. [Arizona Public Service Co., Phoenix, AZ (United States)] [Arizona Public Service Co., Phoenix, AZ (United States)

1995-10-01T23:59:59.000Z

122

Development of a thyristor valve for next generation 500kV HVDC transmission systems  

SciTech Connect (OSTI)

A high voltage thyristor valve is the basic component of an HVDC transmission system. Development of a 500kV valve for next generation HVDC transmission systems is described. First, the power loss of the valve is analyzed to decide a reasonable wafer size for the light triggered thyristor. From these results, a six inch diameter wafer size is selected. The light triggered thyristor, with ratings of 8kV and 3.5kA, is developed using the six inch wafer. The designing of the valve employing the thyristor and test results with the prototype valve prove that a 500kV valve can be realized by the design method.

Hasegawa, T. [Kansai Electric Power Co., Inc., Osaka (Japan)] [Kansai Electric Power Co., Inc., Osaka (Japan); Yamaji, K. [Shikoku Electric Power Co., Inc., Takamatsu (Japan)] [Shikoku Electric Power Co., Inc., Takamatsu (Japan); Irokawa, H. [Electric Power Development Co., Ltd., Tokyo (Japan)] [Electric Power Development Co., Ltd., Tokyo (Japan); Shirahama, H.; Tanaka, C.; Akabane, K.

1996-10-01T23:59:59.000Z

123

Operator Standpoint-Based Remote Operation System Considering the Operational Convenience for a Mobile Robot  

Science Journals Connector (OSTI)

The remotely operated mobile robot is usually controlled in the viewpoint of the mobile robot using the conventional remote operation system. However, it is a little hard ... , we propose the operator standpoint-...

Chang-Seop Shin; Gon-Woo Kim

2013-01-01T23:59:59.000Z

124

Remote actuated valve implant  

SciTech Connect (OSTI)

Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

McKnight, Timothy E; Johnson, Anthony; Moise, Jr., Kenneth J; Ericson, Milton Nance; Baba, Justin S; Wilgen, John B; Evans, III, Boyd McCutchen

2014-02-25T23:59:59.000Z

125

Remotely Deployed Virtual Sensors  

E-Print Network [OSTI]

Remotely Deployed Virtual Sensors TR-UTEDGE-2007-010 Sanem Kabadayi Christine Julien © Copyright 2007 The University of Texas at Austin #12;Remotely Deployed Virtual Sensors Sanem Kabadayi that run on mobile client devices connect to the sensors of a multihop sensor network. For emerging

Julien, Christine

126

EIS-0107: Mead-Phoenix +500-kV Direct Current Transmission Line  

Broader source: Energy.gov [DOE]

The U.S. Department of Energys Western Area Power Administration (WAPA) prepared this statement to analyze the potential environmental and socioeconomic impacts arising from WAPA and regional project sponsors proposal to construct a 500 kilovolt (kV) alternating current (AC) transmission line with the capability to be upgraded later to 500kV direct current (DC), connecting the Westwing Substation, located north of Phoenix, Arizona, with a new McCullough II Substation, located approximately 14 miles west of Boulder City, Nevada. This statement modifies a previously prepared federal statement from which the participants' election to proceed had not occurred at the time this statement was prepared.

127

Consideration of 34. 5 KV as an in-plant voltage for a large industrial user  

SciTech Connect (OSTI)

Traditionally, the in-plant distribution voltage for a large refinery or petrochemical complex has been 13.8 kV. Selection of this voltage level was dictated primarily by economic factors, simply because in most cases the magnitude of the loads or the lengths of the feeders did not produce sufficient savings to compensate for the costlier higher voltage switchgear. This paper presents some engineering and cost considerations for distribution at 34.5 kV and attempts to show that this voltage level is both economically and technically feasible for large electrical systems.

Niculescu, T.D.; Regan, R.R.

1983-09-01T23:59:59.000Z

128

U-061: RSA Adaptive Authentication Bugs Let Remote Users Bypass Certain  

Broader source: Energy.gov (indexed) [DOE]

1: RSA Adaptive Authentication Bugs Let Remote Users Bypass 1: RSA Adaptive Authentication Bugs Let Remote Users Bypass Certain Security Controls U-061: RSA Adaptive Authentication Bugs Let Remote Users Bypass Certain Security Controls December 14, 2011 - 8:17am Addthis PROBLEM: RSA Adaptive Authentication Bugs Let Remote Users Bypass Certain Security Controls. PLATFORM: 6.0.2.1 SP1 Patch 2 and SP1 Patch 3 6.0.2.1 SP2 and SP2 Patch 1 6.0.2.1 SP3 ABSTRACT: A remote user may be able to bypass certain security controls. reference LINKS: SecurityTracker Alert ID: 1026420 Security Focus: ESA-2011-036 IMPACT ASSESSMENT: Medium Discussion: Two vulnerabilities were reported in RSA Adaptive Authentication (On-Premise). A remote user may be able to bypass certain security controls. A remote user can send specially crafted data elements to affect the Device

129

Recreation of Neuronal Kv1 Channel Oligomers by Expression in Mammalian Cells Using Semliki Forest Virus  

Science Journals Connector (OSTI)

The multiple roles of voltage-sensitive K+ channels (Kv1 subfamily) in brain are served by subtypes containing pore-forming ? (1.1?1.6) and auxiliary ? subunits, usually in an (?)4(?)4 stoichiometry. To facilitate structure/activity analysis, combinations ...

Oleg Shamotienko; Sobia Akhtar; Christina Sidera; Frdric A. Meunier; Barbara Ink; Malcolm Weir; J. Oliver Dolly

1999-12-01T23:59:59.000Z

130

Analysis on heat loss characteristics of a 10kV HTS power substation  

Science Journals Connector (OSTI)

Abstract A 10kV High Temperature Superconducting power substation (10kV HTS substation), supported by Chinese State 863 projects, was developed and has been running to supply power for several factories for more than two years at an industrial park of Baiyin, Gansu province in Northwest China. The system of the 10kV HTS substation compositions, including a HTS cable, a HTS transformer, a SFCL, and a SMES, are introduced. The SMES works at liquid helium temperature and the other three apparatus operates under liquid nitrogen condition. There are mainly four types of heat losses existing in each HTS apparatus of the 10kV HTS substation, including AC loss, Joule heat loss, conductive heat, and leak-in heat from cryostat. A small quantity of AC loss still exists due to the harmonic component of the current when it carries DC for HTS apparatus. The principle and basis for analysis of the heat losses are introduced and the total heat loss of each apparatus are calculated or estimated, which agree well with the test result. The analysis and result presented are of importance for the design of the refrigeration system.

Yuping Teng; Shaotao Dai; Naihao Song; Jingye Zhang; Zhiyuan Gao; Zhiqin Zhu; Weiwei Zhou; Zhourong Wei; Liangzhen Lin; Liye Xiao

2014-01-01T23:59:59.000Z

131

A charge-pump 60kV modulator for the ISOLDE target extraction voltage  

E-Print Network [OSTI]

The ISOLDE facility at CERN provides radioactive ion beams to a number of experimental stations. These ions are produced by a metal target, floating at 60 kV, which is impacted by a 1.4 GeV high intensity proton beam. The ions are then accelerated by a grounded extraction electrode to 60 keV, before transport to the experimental area. During proton beam impact extremely high ionisation of the volume around the target gives rise to significant leakage current which results in loss of charge on the effective target capacitance of approximately 6 nF. If short life-time isotopes are to be studied, the 60 kV must be re-established within a maximum of 10 ms. Recharging the target capacitance to 60 kV and to the required stability of better than 10-4 precludes a direct charging system and an alternative method of re-establishing the 60 kV is used. The present system [1], in operation since 1991, employs a resonant circuit which is triggered 35 s prior to beam impact. This circuit transfers the charge on the effec...

Barlow, R A; Fowler, A; Gaudillet, H; Gharsa, T; Schipper, J

2015-01-01T23:59:59.000Z

132

U-061: RSA Adaptive Authentication Bugs Let Remote Users Bypass...  

Broader source: Energy.gov (indexed) [DOE]

Bugs Let Remote Users Bypass Certain Security Controls. PLATFORM: 6.0.2.1 SP1 Patch 2 and SP1 Patch 3 6.0.2.1 SP2 and SP2 Patch 1 6.0.2.1 SP3 ABSTRACT: A remote user may...

133

Final Environmental Assessment of the Trentwood Loop to the Bell-Noxon 230-kV No.1 Line.  

SciTech Connect (OSTI)

The Bonneville Power Administration (BPA) proposes to construct a 2.7mile (4.3-kilometer), 230-kV, double-circuit steel structured trasmission line and to install a 230/115-kV, 300 MVA autotransformer with one 115-kV terminal at Trentwood in unincorporated Spokane County, WA, about 9 miles (14.5 kilometers) east of the City of Spokane. The Bell-Noxon 230-kV No. 1 Line would be opened near Trentwood. The proposed double-circuit line would be tied to the two opened ends of the Bell-Noxon line and brought into a common 230-kV bust at Trentwood Substation via the proposed double-circuit line; this is commonly known as looping a line into a substation. This report addresses the environmental impacts of various alternative solutions. 32 refs, 3 figs., 2 tabs.

United States. Bonneville Power Administration.

1982-05-01T23:59:59.000Z

134

Plasma Immersion Ion Implantation with a 4kV/10kHz Compact High Voltage Pulser  

SciTech Connect (OSTI)

Development of a 4 kV/10 kHz Compact High Voltage Pulser and its application to nitrogen plasma immersion ion implantation (PIII) of different materials as Si, Al alloys, SS304 stainless steel and Ti alloys are discussed. Low voltage (1-5 kV) pulses at high frequencies (up to 20 kHz for 2 kV) were obtained with maximum power delivered at 5 kV, 7 kHz. These conditions were not sufficient to reach temperatures above 200 deg. C in the samples because of short duration of the pulses. However, very shallow implantations of nitrogen in Si, Al5052, SS304 were observed by Auger electron spectroscopy and improved corrosion resistance was obtained for Al5052 when it was treated by nitrogen PIII at 2.5 kV, 5{mu}s and 5 kHz pulses.

Ueda, M.; Oliveira, R. M.; Rossi, J. O. [Associated Laboratory of Plasma, National Institute for Space Research, Av. dos Astronautas 1758, Sao Jose dos Campos, Sao Paulo (Brazil); Reuther, H. [Institute of Ion Beam Physics and Materials Research, Rossendorf, Dresden (Germany); Silva, G. [Associated Laboratory of Plasma, National Institute for Space Research, Av. dos Astronautas 1758, Sao Jose dos Campos, Sao Paulo (Brazil); Department of Aeronautics and Mechanics, Technological Institute of Aeronautics, Sao Jose dos Campos, Sao Paulo (Brazil)

2006-11-13T23:59:59.000Z

135

Combined kV and MV imaging for real-time tracking of implanted fiducial markers  

SciTech Connect (OSTI)

In the presence of intrafraction organ motion, target localization uncertainty can greatly hamper the advantage of highly conformal dose techniques such as intensity modulated radiation therapy (IMRT). To minimize the adverse dosimetric effect caused by tumor motion, a real-time knowledge of the tumor position is required throughout the beam delivery process. The recent integration of onboard kV diagnostic imaging together with MV electronic portal imaging devices on linear accelerators can allow for real-time three-dimensional (3D) tumor position monitoring during a treatment delivery. The aim of this study is to demonstrate a near real-time 3D internal fiducial tracking system based on the combined use of kV and MV imaging. A commercially available radiotherapy system equipped with both kV and MV imaging systems was used in this work. A hardware video frame grabber was used to capture both kV and MV video streams simultaneously through independent video channels at 30 frames per second. The fiducial locations were extracted from the kV and MV images using a software tool. The geometric tracking capabilities of the system were evaluated using a pelvic phantom with embedded fiducials placed on a moveable stage. The maximum tracking speed of the kV/MV system is approximately 9 Hz, which is primarily limited by the frame rate of the MV imager. The geometric accuracy of the system is found to be on the order of less than 1 mm in all three spatial dimensions. The technique requires minimal hardware modification and is potentially useful for image-guided radiation therapy systems.

Wiersma, R. D.; Mao Weihua; Xing, L. [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California 94305-5847 (United States)

2008-04-15T23:59:59.000Z

136

Optimal Design of Remote Terminal Unit (RTU) for Wireless SCADA System for Energy Management  

Science Journals Connector (OSTI)

For energy deficit countries, the design of Supervisory Control and Data Acquisition (SCADA) based energy management systems for optimal distribution is of high interest. Such design involves development of Remote Terminal Unit (RTU) which is considered ... Keywords: Field Programmable Gate Array (FPGA), Programmable Logic Controller (PLC), Remote Terminal Unit (RTU), Supervisory Control and Data Acquisition (SCADA), Tele-Control Interface (TCI), Wireless Communication

Muhammad Aamir; Javier Poncela; Muhammad Aslam Uqaili; B. S. Chowdhry; Nishat Ahmad Khan

2013-04-01T23:59:59.000Z

137

Remote depth survey of the Charles River Basin  

E-Print Network [OSTI]

Unmanned vehicles may provide more time- and cost-effective methods of gathering hydrographic survey data when compared to traditional, manned survey vessels. A remote-controlled unmanned surface vehicle (USV) was outfitted ...

Karlik, Evan A

2007-01-01T23:59:59.000Z

138

Notification of Planned 230kV Outage at Potomac River Generating Station |  

Broader source: Energy.gov (indexed) [DOE]

In accordance with DOE Order No. 202-05-03 Pepco is In accordance with DOE Order No. 202-05-03 Pepco is required to provide notification of any and all 230kV planned outages at Potomac River Generating Station. On Tuesday February 20, 2007 Potomac Electric Power Company (Pepco) will be taking a planned outage on the 23106 high voltage circuit between the Palmer's Corner Substation and the Potomac River Generating Station. Notification of Planned 230kV Outage at Potomac River Generating Station More Documents & Publications Re: Potomac River Generating Station Department of Energy Case No. EO-05-01: Advanced Notice of Power Outages. Special Environmental Analysis For Actions Taken under U.S. Department of Energy Emergency Orders Regarding Operation of the Potomac River Generating Station in Alexandria, Virginia

139

EIS-0365: Imperial-Mexicali 230-kV Transmission Lines  

Broader source: Energy.gov [DOE]

On February 27, 2001, Baja California Power, Inc. (hereafter referred to as Intergen), InterGen Aztec Energy, V.B.V., filed an application with DOE, Office of Fossil Energy, for a Presidential permit that would allow construction and connection of a double-circuit, 230-kV transmission line extending from the Imperial Valley Substation in California for a distance of about 6 mi (10 km) to a point west of Calexico at the U.S.-Mexico border.

140

Template for project inclusion for Remote Sensing Systems' MSU/AMSU brightness temperatures in the C  

E-Print Network [OSTI]

Template for project inclusion for Remote Sensing Systems' MSU/AMSU brightness temperatures- Quality control procedures, including ongoing improvements. Brightness temperatures and geolocation data

Note: This page contains sample records for the topic "kv remote control" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

The Design of Partial Electric and Control System for 500kV Substation  

Science Journals Connector (OSTI)

The good design of the electric section in substation and its stable move may effect the electrical system of substation directly, this paper aim at the design of an electric primary section in substation and its...

Haimei Xiao; Lichun Shi

2012-01-01T23:59:59.000Z

142

Grand Coulee - Bell 500-kV Transmission Line Project, Draft Environmental Impact Statement  

SciTech Connect (OSTI)

BPA is proposing to construct a 500-kilovolt (kV) transmission line that would extend approximately 84 miles between the Grand Coulee 500-kV Switchyard, near Grand Coulee Dam, and the Bell Substation, in Mead just north of Spokane. The new line would cross portions of Douglas, Grant, Lincoln, and Spokane counties. In addition to the transmission line, new equipment would be installed at the substations at each end of the new line and at other facilities. The proposed action would remove an existing 115-kV transmission line and replace it with the new 500-kV line on existing right-of-way for most of its length. Additional right-of-way would be needed in the first 3.5 miles out of the Grand Coulee Switchyard to connect to the existing 115-kV right-of-way. Since the mid-1990s, the transmission path west of Spokane, called the West of Hatwai transmission pathway, has grown increasingly constrained. To date, BPA has been able to manage operation of the path through available operating practices, and customer needed have been met while maintaining the reliability of the path. however, in early 2001, operations showed that the amount of electricity that needs to flow from east to west along this path creates severe transmission congestion. Under these conditions, the system is at risk of overloads and violation of industry safety and reliability standards. The problem is particularly acute in the spring and summer months because of the large amount of power generated by dams east of the path. Large amounts of water cannot be spilled during that time in order for BPA to fulfill its obligation to protect threatened and endangered fish. The amount of power that needs to move through this area during these months at times could exceed the carrying capacity of the existing transmission lines. In additional capacity is not added, BPA will run a significant risk that it will not be able to continue to meet its contractual obligations to deliver power and maintain reliability standards that minimize risks to public safety and to equipment. BPA is considering two construction alternatives, the Agency Proposed Action and the Alternative Action. The Alternative Action would include all the components of the Preferred Action except a double-circuit line would be constructed in the Spokane area between a point about 2 miles west of the Spokane River and Bell Substation, a distance of about 9 miles. BPA is also considering the No Action Alternative.

N /A

2002-08-09T23:59:59.000Z

143

Plasma Phys. Control. Fusion 39 (1997) 367374. Printed in the UK PII: S0741-3335(97)75871-8 Remote launching of plasma modes in the drift frequency  

E-Print Network [OSTI]

in magnetically confined plasmas remains one of the key issues confronting plasma physics research. Although many). The development of methods to modify and control plasma turbulence appears to be a promising area of research in plasma physics (Sen 1994, Buddemeier and Str¨ohljein 1995). Both intrusive (Weynants and Van Oost 1993

van Milligen, Boudewijn

144

T-673: Apple Safari Multiple Flaws Let Remote Users Execute Arbitrary Code,  

Broader source: Energy.gov (indexed) [DOE]

3: Apple Safari Multiple Flaws Let Remote Users Execute 3: Apple Safari Multiple Flaws Let Remote Users Execute Arbitrary Code, Conduct Cross-Site Scripting Attacks T-673: Apple Safari Multiple Flaws Let Remote Users Execute Arbitrary Code, Conduct Cross-Site Scripting Attacks July 21, 2011 - 1:27am Addthis PROBLEM: Multiple vulnerabilities were reported in Apple Safari. A remote user can cause arbitrary code to be executed on the target user's system. A remote user can conduct cross-site scripting attacks. A remote user can obtain potentially sensitive information. A remote user can bypass a certificate validation control. PLATFORM: Safari 5.1 and Safari 5.0.6 Products Affected: Safari 5 (Mac OS X 10.6), Safari 5 (Mac OS X 10.5), Product Security, Safari 5.1 (OS X Lion) ABSTRACT: Apple Safari Multiple Flaws Let Remote Users Execute Arbitrary Code,

145

Fellowships Remote Sensing  

E-Print Network [OSTI]

Fellowships Higher Education Research Remote Sensing K-12 Education Future Flight HI General Public for their outstanding research posters at the First Annual Hawai`i Undergraduate Research Poster Symposium at the UH Manoa Campus Center. Dr. Frank Perkins, Assistant Vice-President for Research and Graduate Education

Chiao, Jung-Chih

146

Cost reduction performance enhancements of multiple site cooling water systems, enabled by remote system monitoring/control and multifaceted data management  

SciTech Connect (OSTI)

An outsourced cooling water treatment automated control and data acquisition package, has been designed, installed, and commissioned in over 70 sites in North America and offshore. The standard package consists of a controller, sensors, human-machine interface software, data acquisition and management software, communications, and reporting. Significant challenges to applying this standard package in multiple sites arose from variations in cooling system design and makeup water quality as well as operations, environmental considerations, metrics, and language. A standard approach has met these challenges and overcome effects of downsizing through significant reduction in non-value-added, manual activities. Overall system reliability has been improved by migration to best practice throughout the organizations involved and immediate proactive response to out-of-specification conditions. This paper documents the evolution of a standard cooling water automation and data management package from its inception to current practice.

Cook, B. [BetzDearborn Water Management Group, Horsham, PA (United States); Young, D. [BetzDearborn Water Management Group, Mississauga, Ontario (Canada); Tari, K. [Praxair, Inc., Tonawanda, New York, NY (United States)

1998-12-31T23:59:59.000Z

147

Seasonal Patterns of Melatonin, Cortisol, and Progesterone Secretion in Female Lambs Raised Beneath a 500-kV Transmission Line.  

SciTech Connect (OSTI)

Although several kinds of biological effects of electric and magnetic fields have been reported from laboratory studies, few have been independently replicated. When this study was being planned, the suppression of nighttime melatonin in rodents was thought to represent one of the strongest known effects of these fields. The effect had been replicated by a single laboratory for 60-Hz electric fields, and by multiple laboratories for d-c magnetic fields. The primary objective of this study was to determine whether the effect of electric and magnetic fields on melatonin would also occur in sheep exposed to a high voltage transmission line. The specific hypothesis tested by this experiment was as follows: The electrical environment produced by a 60-Hz, 500-kV transmission line causes a depression in nocturnal melatonin in chronically exposed female lambs. This may mimic effects of pinealectomy or constant long-day photoperiods, thus delaying the onset of reproductive cycles. Results of the study do not provide evidence to support the hypothesis. Melatonin concentrations in the sheep exposed to the transmission line showed the normal pattern of low daytime and high nighttime serum levels. As compared to the control group, there were no statistically significant group differences in the mean amplitude, phase, or duration of the nighttime melatonin elevation.

Lee, Jack M.

1992-06-01T23:59:59.000Z

148

Portsmouth X300 remote assay monitor system  

SciTech Connect (OSTI)

Personnel in the Instrumentation and Controls Division at Oak Ridge National Laboratory (ORNL) in association with the United States Enrichment Corporation (USEC) have recently developed a system for monitoring and tracking the assay of enriched uranium from the production facilities at the Portsmouth Gaseous Diffusion Plant (PORTS). This work was sponsored by the USEC and has involved the expansion and improvement of an existing system that was developed by ORNL. The system provides control room operators with real-time information on the withdrawal operations of uranium hexafluoride at the withdrawal stations at PORTS. An additional system was developed to display the real-time information from each of the three withdrawal stations at a remotely located building. This report describes the remote assay monitor and display system that has been developed and installed at PORTS Building X300.

Smith, D.E.

1996-07-01T23:59:59.000Z

149

GPRS Based Intranet Remote Administration GIRA  

E-Print Network [OSTI]

In a world of increasing mobility, there is a growing need for people to communicate with each other and have timely access to information regardless of the location of the individuals or the information. With the advent of moblle technology, the way of communication has changed. The gira system is basically a mobile phone technology service. In this paper we discuss about a novel local area network control system called gprs based Intranet Remote Administration gira. This system finds application in a mobile handset. With this system, a network administrator will have an effective remote control over the network. gira system is developed using gprs, gcf Generic Connection Framework of j2me, sockets and rmi technologies

R., Shashi Kumar N; P, Pushpavathi T

2010-01-01T23:59:59.000Z

150

30 kV coaxial vacuum-tight feedthrough for operation at cryogenic temperatures  

E-Print Network [OSTI]

In this paper we describe the technology of building a vacuum-tight high voltage feedthrough which is able to operate at voltages up to 30 kV. The feedthrough has a coaxial structure with a grounded sheath which makes it capable to lead high voltage potentials into cryogenic liquids, without risk of surface discharges in the gas phase above the liquid level. The feedthrough is designed to be used in ionization detectors, based on liquefied noble gases, such as Argon or Xenon.

I. Kreslo; I. Badhrees; S. Delaquis; A. Ereditato; S. Janos; M. Messina; U. Moser; B. Rossi; M. Zeller

2010-11-05T23:59:59.000Z

151

Remote Sensing Laboratory - RSL  

ScienceCinema (OSTI)

One of the primary resources supporting homeland security is the Remote Sensing Laboratory, or RSL. The Laboratory creates advanced technologies for emergency response operations, radiological incident response, and other remote sensing activities. RSL emergency response teams are on call 24-hours a day, and maintain the capability to deploy domestically and internationally in response to threats involving the loss, theft, or release of nuclear or radioactive material. Such incidents might include Nuclear Power Plant accidents, terrorist incidents involving nuclear or radiological materials, NASA launches, and transportation accidents involving nuclear materials. Working with the US Department of Homeland Security, RSL personnel equip, maintain, and conduct training on the mobile detection deployment unit, to provide nuclear radiological security at major national events such as the super bowl, the Indianapolis 500, New Year's Eve celebrations, presidential inaugurations, international meetings and conferences, just about any event where large numbers of people will gather.

None

2015-01-09T23:59:59.000Z

152

Remote Sensing Laboratory - RSL  

SciTech Connect (OSTI)

One of the primary resources supporting homeland security is the Remote Sensing Laboratory, or RSL. The Laboratory creates advanced technologies for emergency response operations, radiological incident response, and other remote sensing activities. RSL emergency response teams are on call 24-hours a day, and maintain the capability to deploy domestically and internationally in response to threats involving the loss, theft, or release of nuclear or radioactive material. Such incidents might include Nuclear Power Plant accidents, terrorist incidents involving nuclear or radiological materials, NASA launches, and transportation accidents involving nuclear materials. Working with the US Department of Homeland Security, RSL personnel equip, maintain, and conduct training on the mobile detection deployment unit, to provide nuclear radiological security at major national events such as the super bowl, the Indianapolis 500, New Year's Eve celebrations, presidential inaugurations, international meetings and conferences, just about any event where large numbers of people will gather.

None

2014-11-06T23:59:59.000Z

153

Remote switch actuator  

DOE Patents [OSTI]

The invention provides a device and method for actuating electrical switches remotely. The device is removably attached to the switch and is actuated through the transfer of a user's force. The user is able to remain physically removed from the switch site obviating need for protective equipment. The device and method allow rapid, safe actuation of high-voltage or high-current carrying electrical switches or circuit breakers.

Haas, Edwin Gerard; Beauman, Ronald; Palo, Jr., Stefan

2013-01-29T23:59:59.000Z

154

Remote Desktop | Argonne National Laboratory  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Remote Desktop Remote Desktop Using Remote Desktop to Connect to Your Work Computer With Remote Desktop, you can have access to a computer at the Laboratory through another computer. For example, you can connect to your work computer from home and have access to all of your programs, files, and network resources as though you were sitting at your computer at work. You can leave programs running at work and see your work desktop displayed on your home computer, with the same programs running. Remote Desktop can be used in many situations, including: Working at home. Access work in progress on your office computer from home and have full access to all local and remote devices. Collaborating. Access your desktop from a colleague's office to work together on projects, such as updating a slide presentation or proofreading

155

Proposal for the award of a contract for the design, supply, installation and commissioning of a 66 kV electrical substation  

E-Print Network [OSTI]

Proposal for the award of a contract for the design, supply, installation and commissioning of a 66 kV electrical substation

2012-01-01T23:59:59.000Z

156

DOE/EA-1470: Environmental Assessment Harry Allen-Mead 500 kV Transmission Line Project Environmental Assessment  

Broader source: Energy.gov (indexed) [DOE]

the the Interior Bureau of Land Management Las Vegas Field Office Las Vegas, Nevada March 2004 Interstate Intertie Centennial Plan Environmental Assessment Harry Allen - Mead 500kV Transmission Line DOE/EA-1470 Harry Allen-Mead 500kV Transmission Line Project Harry Allen-Mead 500kV Transmission Line Environmental Assessment 1 Chapter 1 Purpose and Need 1.1 Introduction The construction of new transmission and distribution facilities is required throughout the western United States to meet the increasing demand for power as more people move to many of the fastest growing communities. According to Executive Order 13212 dated May 18, 2001, "The increased production and transmission of energy in a safe and environmentally sound manner is essential to the well-being of the American people...agencies shall take appropriate actions, to the extent

157

Notification of Planned 230kV Outage at Potomac River Generating Station  

Broader source: Energy.gov (indexed) [DOE]

Sent: Wednesday, May 16, 2007 4:49 PM To: #DOE_Notification@pepco.com Subject: Notification of Planned 230kV Outage at Potomac River Generating Station To Whom It May Concern: This morning Pepco and PJM observed that the generation at the Potomac River Generating Station was having difficulty matching the station generation requirement to the Potomac River area load. Mirant has also informed Pepco and PJM that several generating units were experiencing equipment problems which required them to reduce unit and total plant output. Based on these observations and information received from Mirant, Pepco has elected to cease the current work activities underway on xxxxx high voltage circuit and we will be placing this transmission line back in service this afternoon.

158

A frequency domain model for 3 kV dc traction dc-side resonance identification  

SciTech Connect (OSTI)

Frequency-dependent effects in railway traction power systems arise from the impedance of substation and locomotive line filters and the traction line. Harmonic noise from traction drives and substations can excite resonances and produce overcurrent or overvoltage conditions at critical points in the network. In this paper, the harmonic feeding impedances of a 3 kV DC traction system seen from the rectifier substation, locomotive drive converter and pantograph terminals are presented. Several substation and locomotive filters are considered with a frequency-dependent traction line. Resonances attributed to the substation filter, locomotive filter and traction line are separate and distinct, the line introducing poles and zeros in the audio frequency (AF) range which vary in frequency and magnitude with locomotive position.

Hill, R.J. [Univ. of Bath (United Kingdom). School of Electronic and Electrical Engineering] [Univ. of Bath (United Kingdom). School of Electronic and Electrical Engineering; Fracchia, M.; Pozzobon, P.; Sciutto, G. [Univ. degli Studi di Genova (Italy). Dipt. di Ingegneria Elettrica] [Univ. degli Studi di Genova (Italy). Dipt. di Ingegneria Elettrica

1995-08-01T23:59:59.000Z

159

AC and lightning performance of fiberglass crossarms aged in 115 kV transmission line  

SciTech Connect (OSTI)

This paper presents the results of an investigation of the electrical performance of 115 kV transmission line fiberglass cross-arm used by Mississippi Power and Light Company. A transmission line fiberglass crossarm removed from service and companion cross-arms outdoors but not in service were examined. The evaluation of electrical performance was based on flashover voltage value at AC voltage and standard lightning impulses as well as under dry and wet conditions. The tests were performed in the Mississippi State University High Voltage Laboratory. The obtained flashover voltages show no large differences in electrical strength of fiberglass crossarms removed from service and those stored outdoors. The Added CFO voltage by fiberglass crossarm to the porcelain suspension insulators is presented versus the length of the fiberglass crossarm for dry and wet conditions.

Grzybowski, S. (Mississippi State Univ., Mississippi State, MS (United States). Dept. of Electrical and Computer Engineering); Jenkins, E.B. (Entergy, New Orleans, LA (United States). Generation and Transmission Group)

1993-10-01T23:59:59.000Z

160

Simulation of ion beam transport through the 400 Kv ion implanter at Michigan Ion Beam Laboratory  

SciTech Connect (OSTI)

The Michigan Ion Beam Laboratory houses a 400 kV ion implanter. An application that simulates the ion beam trajectories through the implanter from the ion source to the target was developed using the SIMION Registered-Sign code. The goals were to have a tool to develop an intuitive understanding of abstract physics phenomena and diagnose ion trajectories. Using this application, new implanter users of different fields in science quickly understand how the machine works and quickly learn to operate it. In this article we describe the implanter simulation application and compare the parameters of the implanter components obtained from the simulations with the measured ones. The overall agreement between the simulated and measured values of magnetic fields and electric potentials is {approx}10%.

Naab, F. U.; Toader, O. F.; Was, G. S. [Department of Engineering and Radiological Sciences, University of Michigan, 2355 Bonisteel Boulevard, Ann Arbor, MI 48109-2104 (United States)

2013-04-19T23:59:59.000Z

Note: This page contains sample records for the topic "kv remote control" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Weld-Windsor 115-kV Transmission Line Project, Weld County, Colorado  

SciTech Connect (OSTI)

The Western Area Power Administration is proposing to rebuild a 3.0 mile segment of the existing Flatiron-Weld 115-kV transmission line in Weld County. The line would be reconductored with new conductor on new wood pole double circuit structures. The new structures would support a double circuit transmission line configuration. The first circuit would be owned by Western and the second by Public Service Company of Colorado (PSCO). Alternatives considered included no action, constructing PSCO`s circuit on new right-of-way, and reconductoring Western`s existing line on the same structures. The proposed action was selected because it provided an opportunity to share structures with PSCO and, overall, would minimize costs and environmental impacts. The environmental assessment identifies minor effects on existing natural or human resources and minor benefits for agricultural operations.

NONE

1996-05-01T23:59:59.000Z

162

Final environmental assessment: Los Reales 115 kV transmission line alternative routes  

SciTech Connect (OSTI)

The Central Arizona Project (CAP) was authorized as a part of the Colorado River Basin Project Act (Public Law 90-537) on September 30, 1968. The primary purpose of the CAP is to furnish water for agricultural, municipal, and industrial uses in central and southern Arizona, and western New Mexico. Due to its magnitude, the CAP is divided into several major features serving separate but interrelated functions. The Tucson Aqueduct Phase B pumping plants were designed and constructed to operate on a looped power system. The entire looped power system, including two switching stations and connecting 115-kv transmission lines, was identified in the FEIS and approved for construction in the Secretary of Interior's Record of Decision dated September 24, 1985. The loop begins in the vicinity of the Twin Peaks Pumping Plant -- the northernmost Phase B pumping station, at the Rattlesnake Switching Station. All of the looped power system has been constructed with the exception of the switching station and portion of transmission line proposed to be constructed in this project. Without construction of this final portion of the looped power system, the Phase B pumping plants will not be able to operate normally without negatively affecting nearby power sources. The CAP will also not be able to provide the reliability necessary for municipal water systems dependent upon CAP water. The purpose of this EA is to describe impacts that would result from relocating the Los Reales 115-kV transmission line, and possibly the switching station, originally identified in the FEIS. It should be mentioned the Department of Energy will complete a separate NEPA review.

Not Available

1989-10-01T23:59:59.000Z

163

Remote Facilities | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Remote Facilities Remote Facilities Remote Facilities October 16, 2013 - 4:55pm Addthis Renewable Energy Options for Renovations in Remote Areas Photovoltaics (PV) Small Wind Daylighting Solar Water Heating Passive Solar Design Biomass Heating When a Federal building or facility is located away from existing power lines, many renewable energy technologies including photovoltaics and wind become cost-effective options when compared to extending utilities or transporting fuel for onsite generators. Photovoltaics Photovoltaics (PV) are often cost-effective in remote power applications. In these circumstances, the system is coupled with batteries and can provide complete facility power. Proper system design is critical and must account for the building electrical loads and be sized to meet that load

164

REMOTE ACCESS SERVICES | Department of Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

REMOTE ACCESS SERVICES REMOTE ACCESS SERVICES REMOTE ACCESS SERVICES Access the information you need... Anywhere. Anytime. Different service providers within the Department offer remote access services based on your specific work requirements. If you need assistance, please contact your individual service provider. Energy IT Services (EITS) Remote Access Services Outlook Web Access RSA Token Login RSA Token Instructions HSPD-12 Login HSPD-12 Badge Instructions Virtual Private Network Instructions Citrix Workplace Instructions Energy Information Administration (EIA) Remote Access Services Outlook Web Access EIA VPN Office of Intelligence and Counterintelligence (IN) Remote Access Services Outlook Web Access Office of Science (SC) Remote Access Services Citrix Workplace Help for EITS Customers

165

A way to higher resolution: spherical-aberration correction in a 200 kV transmission electron microscope  

Science Journals Connector (OSTI)

......micrographs, ultramicroscopy 15: 151-172. rical pole-piece dimensions. The 200 kV spherical-aberra- 8 Thust A, Overwijk M H F, coene w M J. and Lentzen M (1996) tion-COrreCted microscope avoids the radiation damage Numerical correction of......

Knut Urban; Bernd Kabius; Max Haider; Harald Rose

1999-01-01T23:59:59.000Z

166

Study on Tubular Busbar Corona Design Optimization of 660kV HVDC Converter Substation in Qingdao  

Science Journals Connector (OSTI)

The HVDC busbar corona characteristic is the main factor taken into account for choosing busbar of HVDC converter substation. By establishing the calculation models of electric field strength along the busbar surface, ground total electric field strength ... Keywords: 660 kV HVDC, converter substation, corona characteristics, electromagnetic, tubular busbar optimization

Xu Mingming; Li Kejun; Tan Zhenyu; Niu Lin

2010-06-01T23:59:59.000Z

167

Development of 6.6kV/1.5kA-Class Superconducting Fault Current Limiter  

Science Journals Connector (OSTI)

The authors have developed and tested a 6.6kV/l.5kA-class superconducting fault current limiter, wound with an AC superconducting wire having ... up to 6.6kV were applied to the limiter. The limiter was able to s...

Kenji Tasaki; Kazuyuki Turunaga; Daisuke Ito

1992-01-01T23:59:59.000Z

168

BNL test electron beam ion source operation on a 100 kV platform ,,abstract...a...,b...  

E-Print Network [OSTI]

BNL test electron beam ion source operation on a 100 kV platform ,,abstract...a...,b... E. N. Beebe to build an electron beam ion source EBIS that will satisfy the requirements of the relativistic heavy ion program. Development studies continue to be carried out on the BNL test EBIS, a half-length full electron

169

T-573: Windows Remote Desktop Client DLL Loading Error Lets Remote Users  

Broader source: Energy.gov (indexed) [DOE]

3: Windows Remote Desktop Client DLL Loading Error Lets Remote 3: Windows Remote Desktop Client DLL Loading Error Lets Remote Users Execute Arbitrary Code T-573: Windows Remote Desktop Client DLL Loading Error Lets Remote Users Execute Arbitrary Code March 9, 2011 - 3:05pm Addthis PROBLEM: Vulnerability in Remote Desktop Client Could Allow Remote Code Execution. PLATFORM: Remote Desktop Connection Client Version(s): 5.2, 6.0, 6.1, 7.0 ABSTRACT: A vulnerability was reported in Windows Remote Desktop Client. A remote user can cause arbitrary code to be executed on the target user's system. reference LINKS: Microsoft Security Bulletin MS11-017 SecurityTracker Alert ID:1025172 CVE-2011-0029 IMPACT ASSESSMENT: Moderate Discussion: A remote user can create a specially crafted DLL file on a remote share (e.g., WebDAV, SMB share). When the target user opens a valid Remote

170

A fiducial detection algorithm for real-time image guided IMRT based on simultaneous MV and kV imaging  

SciTech Connect (OSTI)

The advantage of highly conformal dose techniques such as 3DCRT and IMRT is limited by intrafraction organ motion. A new approach to gain near real-time 3D positions of internally implanted fiducial markers is to analyze simultaneous onboard kV beam and treatment MV beam images (from fluoroscopic or electronic portal image devices). Before we can use this real-time image guidance for clinical 3DCRT and IMRT treatments, four outstanding issues need to be addressed. (1) How will fiducial motion blur the image and hinder tracking fiducials? kV and MV images are acquired while the tumor is moving at various speeds. We find that a fiducial can be successfully detected at a maximum linear speed of 1.6 cm/s. (2) How does MV beam scattering affect kV imaging? We investigate this by varying MV field size and kV source to imager distance, and find that common treatment MV beams do not hinder fiducial detection in simultaneous kV images. (3) How can one detect fiducials on images from 3DCRT and IMRT treatment beams when the MV fields are modified by a multileaf collimator (MLC)? The presented analysis is capable of segmenting a MV field from the blocking MLC and detecting visible fiducials. This enables the calculation of nearly real-time 3D positions of markers during a real treatment. (4) Is the analysis fast enough to track fiducials in nearly real time? Multiple methods are adopted to predict marker positions and reduce search regions. The average detection time per frame for three markers in a 1024x768 image was reduced to 0.1 s or less. Solving these four issues paves the way to tracking moving fiducial markers throughout a 3DCRT or IMRT treatment. Altogether, these four studies demonstrate that our algorithm can track fiducials in real time, on degraded kV images (MV scatter), in rapidly moving tumors (fiducial blurring), and even provide useful information in the case when some fiducials are blocked from view by the MLC. This technique can provide a gating signal or be used for intra-fractional tumor tracking on a Linac equipped with a kV imaging system. Any motion exceeding a preset threshold can warn the therapist to suspend a treatment session and reposition the patient.

Mao Weihua; Riaz, Nadeem; Lee, Louis; Wiersma, Rodney; Xing Lei [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California 94305-5847 (United States)

2008-08-15T23:59:59.000Z

171

The development of a remote monitoring system for the Nuclear Science Center reactor  

E-Print Network [OSTI]

remote access to data from the reactor site is an important part of this project. The two goals of this monitoring system are to control the use of nuclear materials and to monitor the performance of the facility from a remote location. I have designed a...

Jiltchenkov, Dmitri Victorovich

2012-06-07T23:59:59.000Z

172

An Integrated Mapping And Remote Sensing Investigation Of The Structural  

Open Energy Info (EERE)

Mapping And Remote Sensing Investigation Of The Structural Mapping And Remote Sensing Investigation Of The Structural Control For Fumarole Location In The Eburru Volcanic Complex, Kenya Rift Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Conference Paper: An Integrated Mapping And Remote Sensing Investigation Of The Structural Control For Fumarole Location In The Eburru Volcanic Complex, Kenya Rift Details Activities (0) Areas (0) Regions (0) Abstract: The Eburru volcanic complex is located in the central portion of the Kenya Rift. It belongs to the complex of volcanoes - Suswa, Longonot, Olkaria, Eburru, and Menengai - that. form the Kenya Dome. These volcanoes are geothermal fields, and Olkaria is the site for the first geothermal power plant commissioned in 1981 in the East African Rift System (EARS).

173

Remote target removal for the Oak Ridge 86-inch Cyclotron  

SciTech Connect (OSTI)

A remotely operated target remover has been plaed in operation at the 86-Inch Cyclotron located in Oak Ridge. The system provides for the remote removal of a target from inside the cyclotron, loading it into a cask, and the removal of the cask from the 1.5 m (5-ft) shielding walls. The remote system consists of multiple electrical and pneumatically operated equipment which is designed for controlled step-by-step operation, operated with an electrical control panel, and monitored by a television system. The target remover has reduced the radiation exposures to operating personnel at the facility and has increased the effective operating time. The system is fast, requires a minimum of skill to operate, and has demonstrated both reliability and durability.

Walls, A.A.

1982-01-01T23:59:59.000Z

174

Working Remotely | Argonne National Laboratory  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Working Remotely Working Remotely Remote Access Use VPN to access Argonne resources Wake up your computer if power management policies have been applied Connect to your work computer by using Remote Desktop Communications Log into web-based e-mail Outlook Zimbra Send instant messages with Jabber Use Argonne's voice mail and teleconferencing services Use Adobe Connect for web conferencing E-Mail Client and Mobile Device Configuration Changes for Exchange 2010 Cyber Security Secure your home computers Passwords MyPassword Change your password Choosing a good password Other Tools Upload a file for retrieval by others (login required) Argonne SharePoint Server (login required) Inside Argonne (accessible onsite or through VPN) Focal Point Management Blog (accessible onsite or through VPN)

175

NASA Remote Sensing and Archaeology  

Science Journals Connector (OSTI)

Although not its primary mission, NASAs remote sensing missions have been providing ... mounted on both orbital and suborbital platforms, NASA scientists and collaborators from international universities have .....

Marco J. Giardino

2012-01-01T23:59:59.000Z

176

Robotics and remote systems applications  

SciTech Connect (OSTI)

This article is a review of numerous remote inspection techniques in use at the Savannah River (and other) facilities. These include: (1) reactor tank inspection robot, (2) californium waste removal robot, (3) fuel rod lubrication robot, (4) cesium source manipulation robot, (5) tank 13 survey and decontamination robots, (6) hot gang valve corridor decontamination and junction box removal robots, (7) lead removal from deionizer vessels robot, (8) HB line cleanup robot, (9) remote operation of a front end loader at WIPP, (10) remote overhead video extendible robot, (11) semi-intelligent mobile observing navigator, (12) remote camera systems in the SRS canyons, (13) cameras and borescope for the DWPF, (14) Hanford waste tank camera system, (15) in-tank precipitation camera system, (16) F-area retention basin pipe crawler, (17) waste tank wall crawler and annulus camera, (18) duct inspection, and (19) deionizer resin sampling.

Rabold, D.E.

1996-05-01T23:59:59.000Z

177

Remote Sensing Techniques | Open Energy Information  

Open Energy Info (EERE)

Remote Sensing Techniques Remote Sensing Techniques Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: Remote Sensing Techniques Details Activities (0) Areas (0) Regions (0) NEPA(0) Exploration Technique Information Exploration Group: Remote Sensing Techniques Exploration Sub Group: None Parent Exploration Technique: Exploration Techniques Information Provided by Technique Lithology: Stratigraphic/Structural: Hydrological: Thermal: Dictionary.png Remote Sensing Techniques: Remote sensing utilizes satellite and/or airborne based sensors to collect information about a given object or area. Remote sensing data collection methods can be passive or active. Passive sensors (e.g., spectral imagers) detect natural radiation that is emitted or reflected by the object or area

178

Rural community noise caused by 345/138 kV substation transformer  

Science Journals Connector (OSTI)

Residents 360 m (1200 ft) from a large (6 8 4.5 m high) 345/138 kV transformer installed in a new power substation in a rural setting complained of its noise emission especially at night. Octave band and 24?h A?weighted noise measurements were made. The 120?Hz sound level was found to be 90 to 105 dB at the transformer surface. Transformer noise emission did not vary significantly with transformer loading or time of day. The distant (360 m) noise level was from 40 to 47 dBA (N?30 to N?45) depending on intervening terrain and time of day. In calm summer air the annoying sound was found to be in the 125?Hz band at the residence beyond a vegitated rise and 250 to 500 Hz for a residence with line?of?sight contact over a shallow depression. The line?of?sight resident's complaint that the noise was greatest at night was corroborated by the 24?h measurement. That noise level was found to be typically 38 dBA from 11 a.m. to 7 p.m. and 45 dBA from 9 p.m. to 6 a.m. It is postulated that the depression accumulated cool air at night thus refracting the sound onto that site. Recommendations for a noise barrier wall was made to the power company operator.

Angelo J. Campanella

1981-01-01T23:59:59.000Z

179

Draft Environmental Impact Statement for the Imperial-Mexicali 230-kV Transmission Lines  

Broader source: Energy.gov (indexed) [DOE]

Imperial-Mexicali Imperial-Mexicali DEIS 1-4 May 2004 FIGURE 1.1-1 Regional Setting for Imperial-Mexicali 230-kV Transmission Lines Introduction Imperial-Mexicali DEIS 1-5 May 2004 FIGURE 1.1-2 La Rosita Power Complex: Electrical Distribution 2-40 May 2004 Alternatives Imperial-Mexicali DEIS TABLE 2.5-1 Summary of Impacts for Proposed Action and Other Alternatives by Resource Area a For the proposed action, that is, the granting of one or both of the Presidential permits and ROWs, for most resource areas, the analysis was bounded by calculating impacts as if both lines had been allowed. This serves two purposes. First, it demonstrates the maximum possible impacts; second, it clearly presents the combined impacts of the agencies' preferred alternative, that is, permitting both facilities. The only exceptions to this methodology are in the areas of air, water, and human health. Impacts to air, water, and human

180

KvAP1ORQ MthK3LDC Kv12R9R Supplementary Figure S1: Detailed view of TPenA docked into the 3 bestfit  

E-Print Network [OSTI]

of K2P channel block shown in Figure 1. Piechotta et al. Supplementary Information C2 TEA C4 TButA C5 TPenA C6 THexA C7 THepA C8 TOctA #12;Piechotta et al. Supplementary Information Supplementary Figure been published previously; a Milacet al(2011) b Treptow& Klein (2010). KvAP1ORQKv12R9RMthK3LDCKcsA3FB6

Tucker, Stephen J.

Note: This page contains sample records for the topic "kv remote control" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

U-240: Apple Remote Desktop Encryption Failure Lets Remote Users Obtain  

Broader source: Energy.gov (indexed) [DOE]

0: Apple Remote Desktop Encryption Failure Lets Remote Users 0: Apple Remote Desktop Encryption Failure Lets Remote Users Obtain Potentially Sensitive Information U-240: Apple Remote Desktop Encryption Failure Lets Remote Users Obtain Potentially Sensitive Information August 21, 2012 - 7:00am Addthis PROBLEM: Apple Remote Desktop Encryption Failure Lets Remote Users Obtain Potentially Sensitive Information PLATFORM: Apple Remote Desktop after 3.5.1 and prior to 3.6.1 ABSTRACT: A remote user can monitor potentially sensitive information. reference LINKS: Apple.com Apple Article: HT5433 SecurityTracker Alert ID: 1027420 CVE-2012-0681 IMPACT ASSESSMENT: Medium Discussion: A vulnerability was reported in Apple Remote Desktop. When a user connects to a third-party VNC server with the 'Encrypt all network data' setting enabled, network data is not encrypted. A remote user monitoring the

182

DOE/EIS-0365; Final Environmental Impact Statement for the Imperial-Mexicali 230-kV Transmission Lines  

Broader source: Energy.gov (indexed) [DOE]

1 1 FINAL ENVIRONMENTAL IMPACT STATEMENT FOR THE IMPERIAL-MEXICALI 230-kV TRANSMISSION LINES Volume 1: Main Text and Appendixes A-L U.S. Department of Energy Washington, DC U.S. Department of the Interior Bureau of Land Management El Centro, CA Cooperating Agency December 2004 Cover Sheet Imperial-Mexicali FEIS iii December 2004 COVER SHEET RESPONSIBLE FEDERAL AGENCY: U.S. Department of Energy, Office of Fossil Energy COOPERATING AGENCY: U.S. Department of the Interior, Bureau of Land Management TITLE: Final Environmental Impact Statement for the Imperial-Mexicali 230-kV Transmission Lines LOCATION: Imperial County, California CONTACT: For further information on this environmental impact statement (EIS) contact: Mrs. Ellen Russell Office of Electric Power Regulation Office of Fossil Energy, FE-27

183

EIS-0399: Final EIS for the Montana Alberta Tie Ltd. (MATL) 230-KV Transmission Line Comments/Response  

Broader source: Energy.gov (indexed) [DOE]

9 9 Final Environmental Impact Statement for the Montana Alberta Tie Ltd. (MATL) 230-kV Transmission Line VOLUME 2 COMMENT RESPONSE DOCUMENT September 2008 United States Department of Energy State of Montana Department of Environmental Quality COVER SHEET Responsible Agencies: U.S. Department of Energy (DOE) and Montana Department of Environmental Quality (DEQ) are co-lead agencies; the Bureau of Land Management (BLM), U.S. Department of the Interior, is a cooperating agency. Title: Final Environmental Impact Statement for the Montana Alberta Tie Ltd. (MATL) 230-kV Transmission Line (DOE/EIS-0399) Location: Cascade, Teton, Chouteau, Pondera, Toole, and Glacier counties, Montana. Contacts: For further information about this Final EIS, contact: Ellen Russell, Project Manager,

184

DOE/EA-1470: Environmental Assessment Harry Allen-Mead 500 kV Transmission Line Project Environmental Assessment  

Broader source: Energy.gov (indexed) [DOE]

4 4 DOE/EA-1470 DEPARTMENT OF ENERGY Western Area Power Administration Finding of No Significant Impact and Floodplain Statement of Findings Nevada Power Company's Harry Allen-Mead 500-kV Transmission Line Project Summary - Nevada Power Company (Nevada Power) proposes to build a 48- mile, 500-kilovolt (kV) transmission line between the Harry Allen Substation, northeast of Las Vegas Nevada, and the Mead Substation, southeast of Las Vegas (Proposed Action). The project would be part of the Interstate Intertie of the Centennial Plan. Of the 48 miles, 32 miles are within lands managed by the Bureau of Land Management (BLM), 8 miles are within lands managed by the US Bureau of Reclamation (USBR), and 4 miles are within lands managed by Western Area

185

Western Area Power Administration, Desert Southwest Region Parker-Gila 161-kV Transmission Line Maintenance, Cross Arm  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Parker-Gila 161-kV Transmission Line Maintenance, Cross Arm Parker-Gila 161-kV Transmission Line Maintenance, Cross Arm Replacements at Structure 0/7 - Continuation Sheet Special Conditions Biological Resources 1. To avoid impacts to nesting birds, project activities will be scheduled between August 1 and February 15, as feasible. Crews shall not cause injury or death to nesting birds, active nests, eggs, or nestlings. If evidence of a nesting bird is found in the project area, crews shall immediately stop work in that area until Western's Environmental Group has been contacted. 2. A qualified biologist will be present during all project activities and serve as the project's Biological Monitor. The Biological Monitor will be authorized by Western to temporarily halt construction activity if needed to prevent harm to desert tortoise. The Biological Monitor's

186

EIS-0505: Vantage to Pomona Heights 230 kV Transmission Line Project, Yakima, Grant, Benton and Kittitas Counties, Washington  

Broader source: Energy.gov [DOE]

The Bureau of Land Management is preparing, with DOEs Bonneville Power Administration (BPA) as a cooperating agency, an EIS that evaluates the potential environmental impacts of a proposal to construct a 60- to 67-mile long 230-kV transmission line. BPAs proposed action is to interconnect the transmission line to an existing BPA substation. Additional information is available at http://www.blm.gov/or/districts/spokane/plans/vph230/.

187

EIS-0025: Miles City-New Underwood 230-kV Electrical Transmission Line, Montana, North Dakota, and South Dakota  

Broader source: Energy.gov [DOE]

The U.S. Department of Energys Western Area Power Administration prepared this statement to assess the environmental and socioeconomic implications of its proposed action to construct a 3.28-mile, 230-kV transmission line between Miles City and Baker, Montana , Hettinger, North Dakota , and New Underwood , South Dakota , in Custer and Fallon Counties in Montana, Adams , Bowman , and Slope Counties in North Dakota and Meade, Pennington, and Perkins Counties in South Dakota.

188

Reliable and Fault-Tolerant Software-Defined Network Operations Scheme for Remote 3D Printing  

Science Journals Connector (OSTI)

The recent wide expansion of applicable three-dimensional (3D) printing and software-defined networking (SDN) technologies ... of responsiveness and reliability of SDN for remote 3D printing and control processes...

Dongkyun Kim; Joon-Min Gil

2014-12-01T23:59:59.000Z

189

Environmental Assessment of the Gering-Stegall 115-kV Transmission Line Consolidation Project, Scotts Bluff County, Nebraska  

SciTech Connect (OSTI)

The Department of Energy (DOE), Western Area Power Administration (Western) proposes to consolidate segments of two transmission lines near the Gering Substation in Gering, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska, within the city of Gering. Presently, there are three parallel 115-kilovolt (kV) transmission lines on separate rights-of-way (ROW) that terminate at the Gering Substation. The project would include dismantling the Archer-Gering wood-pole transmission line and rebuilding the remaining two lines on single-pole steel double circuit structures. The project would consolidate the Gering-Stegall North and Gering-Stegall South 115-kV transmission lines on to one ROW for a 1.33-mile segment between the Gering Substation and a point west of the Gering Landfill. All existing wood-pole H-frame structures would be removed, and the Gering-Stegall North and South ROWs abandoned. Western is responsible for the design, construction, operation, and maintenance of the line. Western prepared an environmental assessment (EA) that analyzed the potential environmental impacts of the proposed construction, operation, and maintenance of the 115-kV transmission line consolidation. Based on the analyses in the EA, the DOE finds that the proposed action is not a major Federal action significantly affecting the quality of the human environment, within the meaning of the National Environmental Policy Act of 1969 (NEPA).

NONE

1995-05-01T23:59:59.000Z

190

The REMOTE SENSlNf  

Office of Legacy Management (LM)

REMOTE REMOTE SENSlNf ' . 1 ARllRllRRv OF THE UNITED STATES DEPARTMENT OF ENERGY . . . . .a. * ~~&hrEAWWMms Gap ~~&hrEAwwMms Gap ECT FOLLdW-UP REPORT ECT FOLLdW-UP REPORT NOVEMBER 1979 NOVEMBER 1979 AN AERIAL RADIOLOGICAL SURVEY OF THE CURTIS BAY FACILITY OF THE W. FL GRACE COMPANY Baltimore, Maryland t. Kent Hilton Project Scientist APPROVED FORPUBLlCATlON ' : T. P. Stuart, Manager Remote Sensing Sciences Department ATTACHMENT 4- ECT Follow-Up Report AN AERIAL RADIOLOGICAL SURVEY OF THE CURTIS BAY FACILITY This is the second of two reports discussing the gamma ray radiation levels measured at the Curtis Bay facility of the W. R. Grace Company. The first report presented gross count contours and gamma ray spectra over the most active areas. Refined gross count isopleth maps will be

191

T-704: RSA enVision Lets Remote Users View Files and Remote Authenticated  

Broader source: Energy.gov (indexed) [DOE]

704: RSA enVision Lets Remote Users View Files and Remote 704: RSA enVision Lets Remote Users View Files and Remote Authenticated Users Obtain Password T-704: RSA enVision Lets Remote Users View Files and Remote Authenticated Users Obtain Password August 29, 2011 - 3:45am Addthis PROBLEM: Allows remote attackers to obtain sensitive information by sniffing the network or leveraging access to a recipient mailbox. PLATFORM: RSA enVision Version(s): 3.x, 4.x ABSTRACT: RSA enVision lets remote users view files and remote authenticated users obtain password. reference LINKS: SecurityTracker Alert ID: 1025979 CVE-2011-2736 CVE-2011-2737 RSA enVision Product Security IMPACT ASSESSMENT: Medium Discussion: Two vulnerabilities were reported in RSA enVision. A remote user can view files on the target system. A remote authenticated user can obtain

192

T-704: RSA enVision Lets Remote Users View Files and Remote Authenticated  

Broader source: Energy.gov (indexed) [DOE]

4: RSA enVision Lets Remote Users View Files and Remote 4: RSA enVision Lets Remote Users View Files and Remote Authenticated Users Obtain Password T-704: RSA enVision Lets Remote Users View Files and Remote Authenticated Users Obtain Password August 29, 2011 - 3:45am Addthis PROBLEM: Allows remote attackers to obtain sensitive information by sniffing the network or leveraging access to a recipient mailbox. PLATFORM: RSA enVision Version(s): 3.x, 4.x ABSTRACT: RSA enVision lets remote users view files and remote authenticated users obtain password. reference LINKS: SecurityTracker Alert ID: 1025979 CVE-2011-2736 CVE-2011-2737 RSA enVision Product Security IMPACT ASSESSMENT: Medium Discussion: Two vulnerabilities were reported in RSA enVision. A remote user can view files on the target system. A remote authenticated user can obtain

193

The Results of Tests of ASK-100-4UKhL4 Type Asynchronized Compensators at the Beskudnikovo 500kV Substation  

Science Journals Connector (OSTI)

Two ASK-100-4UKhL4 100 Mvar asynchronized compensators were introduced into operation in the 500kV Beskudnikovo substation in 2012. The results of systems tests...

L. G. Volodarskii; I. Ya. Dovganyuk; R. D. Mnev

2014-01-01T23:59:59.000Z

194

DOE/EA-1354; Environmental Assessment for the Fort Collins 115kV Transmission Line Upgrade Project (12/2001)  

Broader source: Energy.gov (indexed) [DOE]

Western Area Power Administration Western Area Power Administration Fort Collins 115-kV Transmission Line Upgrade Project, Fort Collins, Colorado. AGENCY: Western Area Power Administration, DOE ACTION: Finding of no significant impact SUMMARY: The Department of Energy (DOE), Western Area Power Administration (Western) is the lead federal agency for a proposed project to upgrade the electric transmission system in the Fort Collins, Colorado area. Platte River Power Authority (Platte River) is proposing to add additional generation at its Rawhide Power Plant, to rebuild and upgrade segments of Western's existing Flatiron-Poudre and Poudre-Richard's Lake 115-kilovolt (kV) transmission lines, and to install additional 230 kV transmission to Platte River's existing electrical system. Western prepared an environmental assessment (EA) titled "Fort Collins 115kV Transmission

195

EIS-0005-FS: Bonneville Power Administration Proposed FY 1979 Program, Facility Location on Supplement, Southwest Oregon Area Service, Buckley-Summer Lake 500 kV Line, Supplemental  

Broader source: Energy.gov [DOE]

This Bonneville Power Administration document assesses the environmental impacts of constructing transmission facilities, which will coordinate with the Midpoint-Malin 500-kV line to be constructed by the Pacific Power and Light (PP&L) Company. The proposed action includes the construction of the 1.56-mile Buckley-Summer Lake 500-kV transmission line; the proposed Buckley Substation near Maupin, Oregon; and the proposed Summer Lake Substation near Silver Lake, Oregon.

196

16. Recording of Absarption Spectra (Absorption Accessory kit t (55466); 30 kV; 0.08 mA, room normally  

E-Print Network [OSTI]

16. Recording of Absarption Spectra (Absorption Edge) Accessory kit t (55466); 30 kV; 0.08 mA, room set to 30 kV7 16.4. Tabulate counts, I,from 20° (2 8)to 40' at 1' intervals. Fig. 1 8 1 16.5. Locate ktween the K,- and the Kg-line of copper, so that the transmission rate of the Kg-line is very weak while

Browder, Tom

197

Position Description: Remote Sensing/GIS Analyst  

E-Print Network [OSTI]

, gpx, etc. · Aptitude for creating publication quality maps using GIS software Position Description: Remote Sensing/GIS Analyst We are seeking a Remote Sensing/GIS Analyst to support our forest carbon project validation

Mazzotti, Frank

198

Electromagnetic Radiation REFERENCE: Remote Sensing of  

E-Print Network [OSTI]

1 CHAPTER 2: Electromagnetic Radiation Principles REFERENCE: Remote Sensing of the Environment John;2 Electromagnetic Energy Interactions Energy recorded by remote sensing systems undergoes fundamental interactions, creating convectional currents in the atmosphere. c) Electromagnetic energy in the form of electromagnetic

Gilbes, Fernando

199

V-016: HP Performance Insight Bugs with Sybase Database Let Remote Users  

Broader source: Energy.gov (indexed) [DOE]

6: HP Performance Insight Bugs with Sybase Database Let Remote 6: HP Performance Insight Bugs with Sybase Database Let Remote Users Deny Service and Take Full Control of the Target System V-016: HP Performance Insight Bugs with Sybase Database Let Remote Users Deny Service and Take Full Control of the Target System November 5, 2012 - 6:00am Addthis PROBLEM: HP Performance Insight Bugs with Sybase Database Let Remote Users Deny Service and Take Full Control of the Target System PLATFORM: HP Performance Insight v5.31, v5.40 and v5.41 running on HP-UX, Solaris, Linux, and Windows and using Sybase as the database ABSTRACT: Two vulnerabilities were reported in HP Performance Insight. REFERENCE LINKS: HP Support Document ID: c03555488 SecurityTracker Alert ID: 1027719 CVE-2012-3269 CVE-2012-3270 IMPACT ASSESSMENT: High DISCUSSION:

200

T-536: Cisco ASA Multiple Flaws Let Remote Users Deny Service and Bypass  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

36: Cisco ASA Multiple Flaws Let Remote Users Deny Service and 36: Cisco ASA Multiple Flaws Let Remote Users Deny Service and Bypass Security Controls T-536: Cisco ASA Multiple Flaws Let Remote Users Deny Service and Bypass Security Controls January 18, 2011 - 2:30pm Addthis PROBLEM: Cisco ASA Multiple Flaws Let Remote Users Deny Service and Bypass Security Controls. PLATFORM: Cisco 5500 Series Adaptive Security Appliances (ASA) ABSTRACT: Cisco ASA 5500 Series Adaptive Security Appliances are affected by multiple vulnerabilities. Affected versions of Cisco ASA Software vary depending on the specific vulnerability. Cisco ASA 5500 Series Adaptive Security Appliances may experience a TCP connection exhaustion condition (no new TCP connections are accepted) that can be triggered through the receipt of specific TCP segments during the

Note: This page contains sample records for the topic "kv remote control" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

10 January 2009 PHOTOGRAMMETRIC ENGINEERING & REMOTE SENSING High Performance Computing in Remote Sensing  

E-Print Network [OSTI]

10 January 2009 PHOTOGRAMMETRIC ENGINEERING & REMOTE SENSING High Performance Computing in Remote Book ReviewBook Review High Performance Computing in Remote Sensing introduces the most recent advances in the incorporation of the high-performance computing (HPC) paradigm in remote sensing missions. Eighteen well

Plaza, Antonio J.

202

V-127: Samba Bug Lets Remote Authenticated Users Modify Files | Department  

Broader source: Energy.gov (indexed) [DOE]

7: Samba Bug Lets Remote Authenticated Users Modify Files 7: Samba Bug Lets Remote Authenticated Users Modify Files V-127: Samba Bug Lets Remote Authenticated Users Modify Files April 5, 2013 - 6:00am Addthis PROBLEM: A vulnerability was reported in Samba. PLATFORM: The vulnerabilities are reported in version(s): 3.6.0 - 3.6.5 ABSTRACT: A remote authenticated user can modify files on the target share REFERENCE LINKS: SecurityTracker Alert ID: 1028389 Samba Security Announcement CVE-2013-0454 IMPACT ASSESSMENT: Medium DISCUSSION: A remote authenticated user can perform operations on the target CIFS export that are not permitted by the CIFS share access control settings. This may include writing to read-only shares. IMPACT: Modification of user information SOLUTION: Update to 3.6.6 and higher or apply the following patch Addthis

203

V-202: Cisco Video Surveillance Manager Bugs Let Remote Users Obtain  

Broader source: Energy.gov (indexed) [DOE]

2: Cisco Video Surveillance Manager Bugs Let Remote Users 2: Cisco Video Surveillance Manager Bugs Let Remote Users Obtain Potentially Sensitive Information V-202: Cisco Video Surveillance Manager Bugs Let Remote Users Obtain Potentially Sensitive Information July 25, 2013 - 2:52am Addthis PROBLEM: A remote user can obtain potentially sensitive information and modify some configuration settings. A remote user can exploit this to create, modify, and remove camera feeds, archives, logs, and users. PLATFORM: Cisco Video Surveillance Manager 7.1, 7.5 ABSTRACT: Two vulnerabilities were reported in Cisco Video Surveillance Manager REFERENCE LINKS: Security Tracker Alert ID: 1028827 CVE-2013-3429 CVE-2013-3430 CVE-2013-3431 IMPACT ASSESSMENT: Medium DISCUSSION: The vulnerability is due to an access control error that occurred. The

204

V-063: Adobe ColdFusion Bugs Let Remote Users Gain Access and Obtain  

Broader source: Energy.gov (indexed) [DOE]

3: Adobe ColdFusion Bugs Let Remote Users Gain Access and 3: Adobe ColdFusion Bugs Let Remote Users Gain Access and Obtain Information V-063: Adobe ColdFusion Bugs Let Remote Users Gain Access and Obtain Information January 7, 2013 - 1:00am Addthis PROBLEM: Adobe ColdFusion Bugs Let Remote Users Gain Access and Obtain Information PLATFORM: ColdFusion 10, 9.0.2, 9.0.1 and 9.0 for Windows, Macintosh and UNIX ABSTRACT: Adobe has identified three vulnerabilities affecting ColdFusion for Windows, Macintosh and UNIX REFERENCE LINKS: Adobe Security Bulletin APSA13-01 SecurityTracker Alert ID: 1027938 CVE-2013-0625 CVE-2013-0629 CVE-2013-0631 IMPACT ASSESSMENT: High DISCUSSION: A remote user can bypass authentication and take control of the target system [CVE-2013-0625]. Systems with password protection disabled or with no password set are affected.

205

V-127: Samba Bug Lets Remote Authenticated Users Modify Files | Department  

Broader source: Energy.gov (indexed) [DOE]

7: Samba Bug Lets Remote Authenticated Users Modify Files 7: Samba Bug Lets Remote Authenticated Users Modify Files V-127: Samba Bug Lets Remote Authenticated Users Modify Files April 5, 2013 - 6:00am Addthis PROBLEM: A vulnerability was reported in Samba. PLATFORM: The vulnerabilities are reported in version(s): 3.6.0 - 3.6.5 ABSTRACT: A remote authenticated user can modify files on the target share REFERENCE LINKS: SecurityTracker Alert ID: 1028389 Samba Security Announcement CVE-2013-0454 IMPACT ASSESSMENT: Medium DISCUSSION: A remote authenticated user can perform operations on the target CIFS export that are not permitted by the CIFS share access control settings. This may include writing to read-only shares. IMPACT: Modification of user information SOLUTION: Update to 3.6.6 and higher or apply the following patch Addthis

206

Application and Removal of Strippable Coatings via Remote Platform - 13133  

SciTech Connect (OSTI)

Florida International University's (FIU's) Applied Research Center is currently supporting the Department of Energy (DOE) Environmental Management Office of D and D and Facility Engineering program. FIU is supporting DOE's initiative to improve safety, reduce technical risks, and limit uncertainty within D and D operations by identifying technologies suitable to meet specific facility D and D requirements, assessing the readiness of those technologies for field deployment, and conducting feasibility studies and technology demonstrations of selected technologies and working with technology vendors to optimize the design of their current technologies to accomplish dangerous and demanding tasks during D and D operations. To meet one identified technology gap challenge for a technology to remotely apply strippable coatings, fixatives and decontamination gels, FIU identified and performed an initial demonstration of an innovative remote fixative sprayer platform from International Climbing Machines (ICM). The selected technology was demonstrated spraying fixative products at the hot cell mockup facility at the Applied Research Center at FIU in November 2008 under cold (non-radioactive) conditions. The remotely controlled platform was remotely operated and entered the facility and sprayed a fixative onto horizontal and vertical surfaces. Based on the initial FIU demonstration and the specific technical requirements identified at the DOE facilities, a follow-up demonstration was expanded to include strippable coatings and a decontamination gel, which was demonstrated in June 2010 at the ICM facility in Ithaca, NY. This second technology evaluation documented the ability of the remote system to spray the selected products on vertical stainless steel and concrete surfaces to a height of 3 meters (10 feet) and to achieve sufficient coverage and product thickness to promote the ability to peel/remove the strippable coatings and decontamination gel. The next challenge was to determine if a remote platform could be used to remove the strippable coatings and decontamination gels. In 2012, FIU worked with the technology provider, ICM, to conduct feasibility and trade studies to identify the requirements for the remote removal of strippable coatings or decontamination gels using the existing remote controlled platform. (authors)

Shoffner, P.; Lagos, L. [Applied Research Center, Florida International University, 10555 West Flagler Street, Suite 2100, Miami, FL 33174 (United States)] [Applied Research Center, Florida International University, 10555 West Flagler Street, Suite 2100, Miami, FL 33174 (United States); Maggio, S. [International Climbing Machine, 630 Elmira Road, Ithaca, NY 14850 (United States)] [International Climbing Machine, 630 Elmira Road, Ithaca, NY 14850 (United States)

2013-07-01T23:59:59.000Z

207

CONTROL SYSTEM FOR SOLAR HEATING and COOLING  

E-Print Network [OSTI]

sensors and control valves used in our generalized experimental system. The experimental solarsensors are remotely located at critical (in terms of decision-making) locations in the solar

Dols, C.

2010-01-01T23:59:59.000Z

208

Connecting Remote Clusters with ATM  

SciTech Connect (OSTI)

Sandia's entry into utilizing clusters of networked workstations is called Computational Plant or CPlant for short. The design of CPlant uses Ethernet to boot the individual nodes, Myrinet to communicate within a node cluster, and ATM to connect between remote clusters. This SAND document covers the work done to enable the use of ATM on the CPlant nodes in the Fall of 1997.

Hu, T.C.; Wyckoff, P.S.

1998-10-01T23:59:59.000Z

209

Improving Pacific Intertie Stability Using Slatt Thyristor Controlled Series Compensation  

E-Print Network [OSTI]

design issues for the existing thyristor controlled series compensation (TCSC) device at Slatt substation on the Slatt­Buckley 500-kV transmission line owned by BPA. The controls were developed at Washington State University (WSU) in a project funded by Bonneville Power Administration (BPA). The project has been carried

Venkatasubramanian, Mani V.

210

DOE/EIS-0365; Final Environmental Impact Statement for the Imperial-Mexicali 230-kV Transmission Lines  

Broader source: Energy.gov (indexed) [DOE]

2 2 FINAL ENVIRONMENTAL IMPACT STATEMENT FOR THE IMPERIAL-MEXICALI 230-kV TRANSMISSION LINES Volume 2: Comment and Response Document U.S. Department of Energy Washington, DC U.S. Department of the Interior Bureau of Land Management El Centro, CA Cooperating Agency December 2004 Comment and Response Document Imperial-Mexicali FEIS iii December 2004 CONTENTS NOTATION .......................................................................................................................... v ENGLISH/METRIC AND METRIC/ENGLISH EQUIVALENTS..................................... ix 1 PUBLIC REVIEW OF THE DRAFT ENVIRONMENTAL IMPACT STATEMENT ................................................................................................................ 1-1 1.1 Overview of the Public Review Process

211

Definition: Remote Sensing Techniques | Open Energy Information  

Open Energy Info (EERE)

Remote Sensing Techniques Remote Sensing Techniques Jump to: navigation, search Dictionary.png Remote Sensing Techniques Remote sensing utilizes satellite and/or airborne based sensors to collect information about a given object or area. Remote sensing data collection methods can be passive or active. Passive sensors (e.g., spectral imagers) detect natural radiation that is emitted or reflected by the object or area being observed. In active remote sensing (e.g., radar) energy is emitted and the resultant signal that is reflected back is measured.[1] View on Wikipedia Wikipedia Definition Remote sensing is the acquisition of information about an object or phenomenon without making physical contact with the object. In modern usage, the term generally refers to the use of aerial sensor technologies

212

CMS FNAL Remote Operations Center  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

LHC@FNAL Remote Operations Center (ROC) at Fermilab is located on the first floor of Wilson Hall. From the ROC, shifters perform real-time monitoring of the data recorded by the CMS Experiment. LHC@FNAL Remote Operations Center (ROC) at Fermilab is located on the first floor of Wilson Hall. From the ROC, shifters perform real-time monitoring of the data recorded by the CMS Experiment. ROC WBM / WBM Twiki FNAL ELog Mailing List Agendas / ROC Presentations & Notes WBM Publications Runs CVS SiTracker / MTCC AEM / AEM help Screen Snapshot Service FAQ Accounts & Nodes New User Instructions WebCams CMS Workbook Directories / Glossaries Photos Vidyo / EVO Google / Wikipedia LHC@FNAL Computing Console Map Documents Mailing List One East Mtg Schedule rocshare Telephones To Do List Video Conferencing CMS Shifter CSC DAQ DataOps DQM / FNAL ROC ECAL Event Display HCAL Pixel Trigger Global Run Calendar CMS Live Contact List DAQ Status DAS

213

OPERATIONAL RESULTS OF THE SPALLATION NEUTRON SOURCE (SNS) POLYPHASE CONVERTER-MODULATOR FOR THE 140 KV KLYSTRON RF SYSTEMS  

SciTech Connect (OSTI)

This paper describes the first operational results of the 140 kV, 1 MW average, 11 MW peak, zero-voltage-switching, 20 kHz polyphase bridge, boost converter-modulator for klystron pulse application. The DC-DC converter derives the buss voltages from a standard 13.8 kV to 2100 Y substation cast-core transformer. Energy storage and filtering is provided by self-clearing metallized hazy polypropylene traction capacitors. Three ''H-Bridge'' Insulated Gate Bipolar Transistor (IGBT) switching networks are used to generate the polyphase 20 kHz transformer primary drive waveforms. The 20 kHz drive waveforms are chirped the appropriate duration to generate the desired klystron pulse width. Pulse-Width Modulation (PWM) of the individual 20 kHz pulses is utilized to provide regulated output waveforms with adaptive feedforward and feedback techniques. The boost transformer design utilizes amorphous nanocrystalline material that provides the required low core loss at design flux levels and switching frequencies. Resonant shunt peaking is used on the transformer secondary to boost output voltage and resonate transformer leakage inductance. With the appropriate transformer leakage inductance and peaking capacitance, zero-voltage-switching of the IGBT's is attained, minimizing switching losses. Reviews of these design parameters and an examination of the first operational results will be performed.

W.A. REASS; J.D. DOSS; ET AL

2001-06-01T23:59:59.000Z

214

Quench current degradation in superconducting coil for 6.6 kV/2 fault current limiter  

SciTech Connect (OSTI)

A 6.6 kV/2 kA class fault current limiter that consists of non-inductive superconducting windings was developed and tested. The limiter can deliver continuous power at 2 kArms and limit fault current of more than 20 kA to 4 kA in 6 kV. The limiter recovers to the superconducting state within a few seconds and can perform a fault current limiting operation in 60 seconds after the last limiting operation. After high-voltage operation, however, the quench current of the limiter dropped significantly. This quench current degradation is related to the coil bobbin strain due to helium pressure raised by large ohmic heating in quenching. The degradation is a fatal problem for a fault current limiter if the quench current falls below the operating current because the limiter cannot revert to the normal operation. High Young`s modulus bobbin is effective to remove the coil degradation. They have obtained a fault current limiter without any degradation after repeated limiting operations.

Tasaki, K.; Yazawa, T.; Yoneda, E.S.; Nomura, S.; Maeda, H. [Toshiba Corp., Kawasaki (Japan). Research and Development Center] [Toshiba Corp., Kawasaki (Japan). Research and Development Center; Ohkuma, T.; Nakade, M.; Hara, T. [Tokyo Electric Power Co., Yokohama (Japan). Power Engineering R and D Center] [Tokyo Electric Power Co., Yokohama (Japan). Power Engineering R and D Center

1996-07-01T23:59:59.000Z

215

Federal Draft Environmental Impact Statement and State of Montana Supplemental Draft Environmental Impact Statement for the Montana Alberta Tie Ltd. (MATL) 230-kV Transmission Line  

Broader source: Energy.gov (indexed) [DOE]

S-1 S.1 Introduction This document is both a State of Montana Supplemental Draft Environmental Impact Statement (EIS) and a U.S. Department of Energy (DOE) Federal Draft EIS (referred to herein as the Draft EIS for both state and federal purposes) prepared for the United States portion of the proposed Montana Alberta Tie Ltd. (MATL) 230-kilovolt (kV) transmission line. MATL has proposed to construct an international 230-kV alternating current merchant (private) transmission line that would originate at an existing NorthWestern Energy (NWE) 230-kV switch yard at Great Falls, Montana, and extend north to a new substation to be constructed northeast of Lethbridge, Alberta, crossing the U.S.-Canada international border north of Cut Bank, Montana (proposed Project). Approximately

216

Stridsvagn 122 och Remote Weapon Station.  

E-Print Network [OSTI]

?? Den hr uppsatsen behandlar stridsvagn122 och Remote Weapon Station (RWS). Det finns ett verkansglapp mellan dagens kalibrar 120 mm och 7,62 mm. Observationsmjligheterna i (more)

Sellberg, Martin

2010-01-01T23:59:59.000Z

217

Improvements in the computation of balances and localization of commercial losses of electric energy in 0.38-kV networks  

SciTech Connect (OSTI)

An example of four 0.38-kV overhead distribution lines fed from a 10/0.4-kV transformer substation of the Grodno Electrical Networks (Belarus') and supplying electricity to a cottage area is used for analyzing energy balances and commercial losses in the networks. It is shown that the reliability of such analysis can be ensured by the use of modern software and electronic energy meters recording a retrospective of half-hourly intervals of active and reactive electric energy.

Vorotnitskii, V. Z.; Zaslonov, S. V.; Lysyuk, S. S. [Electric Power Research Institute (VNIIE) (Russian Federation)

2006-11-15T23:59:59.000Z

218

Design and Simulation of Novel Enhancement Mode 520 kV GaN Vertical Superjunction High Electron Mobility Transistors for Smart Grid Applications  

Science Journals Connector (OSTI)

We report on the design, simulations and optimization of a novel enhancement mode 520 kV GaN vertical superjunction (SJ) high electron mobility transistor (HEMT). We optimize the space charge in GaN pillars using GaN SJ pn diode for the best trade-off between breakdown voltage (BV) and specific on-resistance (Ronsp), by varying the pillar dosage, length and width. The resulting GaN SJ field effect transistor (FET) structure is projected to have, for example, Ronsp of 4.2 m? cm2 with BV of 12.4 kV.

Zhongda Li; T. Paul Chow

2013-01-01T23:59:59.000Z

219

Remote Sens. 2013, 5, 5173-5192; doi:10.3390/rs5105173 Remote Sensing  

E-Print Network [OSTI]

Remote Sens. 2013, 5, 5173-5192; doi:10.3390/rs5105173 Remote Sensing ISSN 2072-4292 www for a geosynchronous OPEN ACCESS #12;Remote Sens. 2013, 5 5174 satellite with modern imaging detectors, software, and algorithms able to detect heat from early and small fires, and yield minute-scale detection times. Keywords

Stephens, Scott L.

220

Remote Sens. 2013, 5, 5969-5998; doi:10.3390/rs5115969 Remote Sensing  

E-Print Network [OSTI]

Remote Sens. 2013, 5, 5969-5998; doi:10.3390/rs5115969 Remote Sensing ISSN 2072-4292 www, the technique presented in this paper would help them to quantify the impacts of OPEN ACCESS #12;Remote Sens; urban heat island effect; NDVI; artificial neural network; Markov chain; Dhaka 1. Introduction Urban

Crawford, Ian

Note: This page contains sample records for the topic "kv remote control" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

HTS dc bias coil for 35kV/90MVA saturated iron-core fault current limiter  

Science Journals Connector (OSTI)

A superconductive coil with 141,000 ampere-turns designed magnetizing power, made of 17,600 meters of BSCCO 2223 HTS tapes, was fabricated and tested. This coil was built for a 35kV/90MVA saturated iron-core fault current limiter. Computer simulations on the performance of the coil were carried out using ANSYS. The critical current of the superconducting coil and the dc resistance of the coil, including the non-superconducting joints, were investigated. Spatial distribution of the magnetic field was measured and compared with the simulation results. In this paper, we will report the configuration and the key parameters of the coil as well as the experimental and simulation results.

W.Z. Gong; J.Y. Zhang; Z.J. Cao; H. Hong; B. Tian; Y. Wang; J.Z. Wang; X.Y. Niu; J. Qiu; S.H. Wang; Y. Xin

2008-01-01T23:59:59.000Z

222

V-223: RSA Authentication Agent for PAM Allows Remote Users to Make  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

3: RSA Authentication Agent for PAM Allows Remote Users to Make 3: RSA Authentication Agent for PAM Allows Remote Users to Make Unlimited Login Attempts V-223: RSA Authentication Agent for PAM Allows Remote Users to Make Unlimited Login Attempts August 21, 2013 - 6:00am Addthis PROBLEM: A vulnerability was reported in RSA Authentication Agent for PAM PLATFORM: RSA Authentication Agent for PAM 7.0.2 and prior ABSTRACT: A remote user can make unlimited login attempts REFERENCE LINKS: Security Tracker Alert ID 1028930 CVE-2013-3271 IMPACT ASSESSMENT: Medium DISCUSSION: The system does not restrict the number of login attempts made via the agent IMPACT: System Access SOLUTION: Vendor has issued a fix Addthis Related Articles U-267: RSA® Authentication Agent 7.1 for Microsoft Windows® and RSA® Authentication Client 3.5 Access Control Vulnerability

223

T-569: Adobe Flash SWF File Processing Memory Corruption Remote Code  

Broader source: Energy.gov (indexed) [DOE]

9: Adobe Flash SWF File Processing Memory Corruption Remote 9: Adobe Flash SWF File Processing Memory Corruption Remote Code Execution Vulnerability T-569: Adobe Flash SWF File Processing Memory Corruption Remote Code Execution Vulnerability March 3, 2011 - 3:05pm Addthis PROBLEM: Adobe Flash Player contains a vulnerability that could allow an unauthenticated, remote attacker to execute arbitrary code on a targeted system. PLATFORM: Adobe Flash Player versions 10.1.102.64 and prior ABSTRACT: Critical vulnerabilities have been identified in Adobe Flash Player 10.1.102.64 and earlier versions for Windows, Macintosh, Linux, and Solaris. These vulnerabilities could cause the application to crash and could potentially allow an attacker to take control of the affected system. reference LINKS: Cisco IntelliShield ID:22576 Adobe Security Update: APSB11-02

224

T-569: Adobe Flash SWF File Processing Memory Corruption Remote Code  

Broader source: Energy.gov (indexed) [DOE]

9: Adobe Flash SWF File Processing Memory Corruption Remote 9: Adobe Flash SWF File Processing Memory Corruption Remote Code Execution Vulnerability T-569: Adobe Flash SWF File Processing Memory Corruption Remote Code Execution Vulnerability March 3, 2011 - 3:05pm Addthis PROBLEM: Adobe Flash Player contains a vulnerability that could allow an unauthenticated, remote attacker to execute arbitrary code on a targeted system. PLATFORM: Adobe Flash Player versions 10.1.102.64 and prior ABSTRACT: Critical vulnerabilities have been identified in Adobe Flash Player 10.1.102.64 and earlier versions for Windows, Macintosh, Linux, and Solaris. These vulnerabilities could cause the application to crash and could potentially allow an attacker to take control of the affected system. reference LINKS: Cisco IntelliShield ID:22576 Adobe Security Update: APSB11-02

225

Remotely readable fiber optic compass  

DOE Patents [OSTI]

A remotely readable fiber optic compass. A sheet polarizer is affixed to a magnet rotatably mounted in a compass body, such that the polarizer rotates with the magnet. The optical axis of the sheet polarizer is preferably aligned with the north-south axis of the magnet. A single excitation light beam is divided into four identical beams, two of which are passed through the sheet polarizer and through two fixed polarizing sheets which have their optical axes at right angles to one another. The angle of the compass magnet with respect to a fixed axis of the compass body can be determined by measuring the ratio of the intensities of the two light beams. The remaining ambiguity as to which of the four possible quadrants the magnet is pointing to is resolved by the second pair of light beams, which are passed through the sheet polarizer at positions which are transected by two semicircular opaque strips formed on the sheet polarizer. The incoming excitation beam and the four return beams are communicated by means of optical fibers, giving a remotely readable compass which has no electrical parts.

Migliori, Albert (Santa Fe, NM); Swift, Gregory W. (Los Alamos, NM); Garrett, Steven L. (Pebble Beach, CA)

1986-01-01T23:59:59.000Z

226

Satellite remote sensing, biodiversity research and conservation of the future  

Science Journals Connector (OSTI)

...our special issue entitled Satellite Remote Sensing for Biodiversity...on the future prospects of satellite remote sensing for biodiversity...powerful understanding of weather and climate, along with other...conservation agendas [24]. Satellite remote sensing, on the other...

2014-01-01T23:59:59.000Z

227

U-192 VMware Workstation/Player VM Remote Device Bug Lets Local or Remote  

Broader source: Energy.gov (indexed) [DOE]

VMware Workstation/Player VM Remote Device Bug Lets Local or VMware Workstation/Player VM Remote Device Bug Lets Local or Remote Users Deny Service U-192 VMware Workstation/Player VM Remote Device Bug Lets Local or Remote Users Deny Service June 15, 2012 - 7:00am Addthis PROBLEM: A vulnerability was reported in VMware Workstation/Player. PLATFORM: Version(s): Workstation 8.x, Player 4.x ABSTRACT: A local or remote user can cause denial of service conditions on the target virtual system. reference LINKS: Vendor Advisory Security Tracker ID 1027173 CVE-2012-3289 IMPACT ASSESSMENT: High Discussion: A user with the ability to modify communications data between a remote virtual device (e.g., CD-ROM, keyboard) located on a physically separate system and the target virtual machine can cause the target virtual machine to crash. Impact:

228

U-192: VMware Workstation/Player VM Remote Device Bug Lets Local or Remote  

Broader source: Energy.gov (indexed) [DOE]

92: VMware Workstation/Player VM Remote Device Bug Lets Local or 92: VMware Workstation/Player VM Remote Device Bug Lets Local or Remote Users Deny Service U-192: VMware Workstation/Player VM Remote Device Bug Lets Local or Remote Users Deny Service June 15, 2012 - 7:00am Addthis PROBLEM: A vulnerability was reported in VMware Workstation/Player. PLATFORM: Version(s): Workstation 8.x, Player 4.x aBSTRACT: A local or remote user can cause denial of service conditions on the target virtual system. reference LINKS: Vendor Advisory Security Tracker ID 1027173 CVE-2012-3289 IMPACT ASSESSMENT: High Discussion: A user with the ability to modify communications data between a remote virtual device (e.g., CD-ROM, keyboard) located on a physically separate system and the target virtual machine can cause the target virtual machine to crash.

229

Type A Accident Investigation Report on the June 25, 1997, Contractor Inspector Fatality on the Satsop-Aberdeen #2 & #3 230 kV Line  

Broader source: Energy.gov [DOE]

On June 27, 1997, I established a Type-A Accident Investigation Board to investigate the June 25, 1997 fatal contractor accident which occurred on BPA?s Satsop-Aberdeen #2 and #3 230-kV transmission lines right-of-way.

230

Increasing the reliability of the shutdown of 500 - 750-kV overhead lines equipped with shunt reactors in an unsuccessful three-phase automatic repeated closure cycle  

SciTech Connect (OSTI)

The reasons for circuit-breaker failures during repeated disconnection of 500 - 750 kV overhead lines with shunt reactors in a cycle of unsuccessful three-phase automatic reconnection (TARC) are analyzed. Recommendations are made for increasing the operating reliability of power transmission lines with shunt reactors when there is unsuccessful reconnection.

Kuz'micheva, K. I.; Merzlyakov, A. S.; Fokin, G. G. [JSC 'R and D Center at Federal Grid Company of the United Power System' (Russian Federation)

2013-05-15T23:59:59.000Z

231

U-154: IBM Rational ClearQuest ActiveX Control Buffer Overflow...  

Broader source: Energy.gov (indexed) [DOE]

Architect ActiveBar ActiveX Control Lets Remote Users Execute Arbitrary Code V-020: Apple QuickTime Multiple Flaws Let Remote Users Execute Arbitrary Code U-126: Cisco Adaptive...

232

T-613: Microsoft Excel Axis Properties Remote Code Execution...  

Broader source: Energy.gov (indexed) [DOE]

3: Microsoft Excel Axis Properties Remote Code Execution Vulnerability T-613: Microsoft Excel Axis Properties Remote Code Execution Vulnerability May 2, 2011 - 7:42am Addthis...

233

T-569: Adobe Flash SWF File Processing Memory Corruption Remote...  

Broader source: Energy.gov (indexed) [DOE]

69: Adobe Flash SWF File Processing Memory Corruption Remote Code Execution Vulnerability T-569: Adobe Flash SWF File Processing Memory Corruption Remote Code Execution...

234

T-557: Microsoft Office Excel Office Art Object Parsing Remote...  

Broader source: Energy.gov (indexed) [DOE]

7: Microsoft Office Excel Office Art Object Parsing Remote Code Execution Vulnerability T-557: Microsoft Office Excel Office Art Object Parsing Remote Code Execution Vulnerability...

235

T-526: Microsoft Internet Explorer 'ReleaseInterface()' Remote...  

Broader source: Energy.gov (indexed) [DOE]

26: Microsoft Internet Explorer 'ReleaseInterface()' Remote Code Execution Vulnerability T-526: Microsoft Internet Explorer 'ReleaseInterface()' Remote Code Execution Vulnerability...

236

T-541: Citrix Provisioning Services Unspecified Flaw Let's Remote...  

Broader source: Energy.gov (indexed) [DOE]

Citrix Provisioning Services Unspecified Flaw Let's Remote Users Execute Arbitrary Code T-541: Citrix Provisioning Services Unspecified Flaw Let's Remote Users Execute Arbitrary...

237

Solar in Remote Applications in the United States | Department...  

Energy Savers [EERE]

in Remote Applications in the United States Solar in Remote Applications in the United States Renewable energy and distributed generation resources have a critical role to play in...

238

V-202: Cisco Video Surveillance Manager Bugs Let Remote Users...  

Broader source: Energy.gov (indexed) [DOE]

2: Cisco Video Surveillance Manager Bugs Let Remote Users Obtain Potentially Sensitive Information V-202: Cisco Video Surveillance Manager Bugs Let Remote Users Obtain Potentially...

239

U-047: Siemens Automation License Manager Bugs Let Remote Users...  

Broader source: Energy.gov (indexed) [DOE]

7: Siemens Automation License Manager Bugs Let Remote Users Deny Service or Execute Arbitrary Code U-047: Siemens Automation License Manager Bugs Let Remote Users Deny Service or...

240

V-103: RSA Authentication Agent Lets Remote Users Bypass Authenticatio...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

RSA Authentication Agent Lets Remote Users Bypass Authentication Requirements March 4, 2013 - 12:27am Addthis PROBLEM: RSA Authentication Agent Lets Remote Users Bypass...

Note: This page contains sample records for the topic "kv remote control" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

V-176: Adobe Flash Player Memory Corruption Flaw Lets Remote...  

Broader source: Energy.gov (indexed) [DOE]

6: Adobe Flash Player Memory Corruption Flaw Lets Remote Users Execute Arbitrary Code V-176: Adobe Flash Player Memory Corruption Flaw Lets Remote Users Execute Arbitrary Code June...

242

V-139: Cisco Network Admission Control Input Validation Flaw...  

Broader source: Energy.gov (indexed) [DOE]

Sensitive Information U-270:Trend Micro Control Manager Input Validation Flaw in Ad Hoc Query Module Lets Remote Users Inject SQL Commands U-015: CiscoWorks Common...

243

Remote Manipulation for D&D Exhibiting Teleautonomy and Telecollaboration  

SciTech Connect (OSTI)

The purpose of the work is to enhance remote operations of robotic systems for D&D tasks by extending teleoperation with semi-autonomous functions. The work leverages the $1.2M dual-arm work platform (DAWP) developed with broad participation for the CP5 D&D, as well as 2,000 hr DAWP D&D operational experience. We propose to develop a reactive, agent-based control architecture well suited to unstructured and unpredictable environments, and robot control technology, which implements a virtual fixture that can be used to guide the application of tools with force-feedback control. Developed methodologies will be implemented using a structured light sensor and robot hand controller on the dual-arm system.

Ewing, Thomas F.; Colgate, J. Edward; Park, Young S.; Peshkin, Michael A.

2004-06-01T23:59:59.000Z

244

Free-Piston Diesel Engine Dynamics and Control Tor A. Johansen1, Olav Egeland  

E-Print Network [OSTI]

Free-Piston Diesel Engine Dynamics and Control Tor A. Johansen1, Olav Egeland , Erling Aa. Kv rner ASA, Postboks 169, N-1325 Lysaker, Norway. Abstract Free-piston diesel engines. This paper present a dynamic mathematical model of a free-piston diesel engine, a control oriented dynamic

Johansen, Tor Arne

245

Remote Chemical Sensing Using Quantum Cascade Lasers  

SciTech Connect (OSTI)

Research done by the IR sensors team at PNNL is focused on developing advanced spectroscopic methods for detecting signatures of nuclear, chemical, biological and explosives weapons or weapons production. The sensors we develop fall into two categories: remote sensors that can be operated at distances ranging from 150 m to 10 km, and point sensors that are used for in-situ inspection and detection. FY03 has seen an explosion in FM DIAL progress with the net result being solid confirmation that FM DIAL is a technique capable of remote chemical monitoring in a wide variety of venues. For example, FM DIAL was used to detect a small plume of hydrogen sulfide, a candidate CW agent, released in the desert environment of the Hanford 200 Area site. These experiments were conducted over a range of physical conditions including outside temperatures ranging from 70 F to 105 F and turbulence conditions ranging from quiescent to chaotic. We are now rapidly developing the information needed to design prototype FM DIAL systems that are optimized for specific applications that include scenarios such as fixed position stand-off detection and mobile UAV mounted remote monitoring. Just as an example, in FY04 we will use FM DIAL to detect both in-facility and outdoor release of enriched UF6. The rapid progress in FM DIAL research made in FY03 is attributed to several advances. First, final construction of a custom-designed trailer allowed the instrument to be housed in a mobile temperature-controlled environment. This allowed the experiment to be transported to several locations so that data could be collected under a range of physical conditions. This has led to a better understanding of a variety of experimental noise sources. With this knowledge, we have been able to implement several changes in the way the FM DIAL data is collected and processed, with the net result being a drastic improvement in our confidence of analyte concentration measurement and an improvement i n the instrument detection limit. The range of chemicals detectable by FM DIAL has also been extended. Prior to FY03 only water and nitrous oxide (N2O) had been seen. Experiments on extending the tuning range of the quantum cascade laser (QCL) currently used in the experiments demonstrate that many more species are now accessible including H2S, C2F4H2, and CH4. We additionally demonstrated that FM DIAL measurements can be made using short wave infrared (SWIR) telecommunications lasers. While measurements made using these components are noisier because turbulence and particulate matter cause more interference in this spectral region, monitoring in this region enables larger species to be detected simply because these lasers have a greater tuning range. In addition, SWIR monitoring also allows for the detection of second-row hydride species such as HF and HCl, which are important nuclear and CWA proliferation signatures.

Harper, Warren W.; Strasburg, Jana D.; Aker, Pam M.; Schultz, John F.

2004-01-20T23:59:59.000Z

246

Remote-handled transuranic system assessment appendices. Volume 2  

SciTech Connect (OSTI)

Volume 2 of this report contains six appendices to the report: Inventory and generation of remote-handled transuranic waste; Remote-handled transuranic waste site storage; Characterization of remote-handled transuranic waste; RH-TRU waste treatment alternatives system analysis; Packaging and transportation study; and Remote-handled transuranic waste disposal alternatives.

NONE

1995-11-01T23:59:59.000Z

247

On-road remote sensing of vehicle emissions in  

E-Print Network [OSTI]

On-road remote sensing of vehicle emissions in the Auckland Region August 2003 Technical 1877353000 www.arc.govt.nz #12;TP 198 On-Road Remote Sensing of Vehicle Emissions in the Auckland Region #12;Page i TP 198 On-Road Remote Sensing of Vehicle Emissions in the Auckland Region On-road remote sensing

Denver, University of

248

"Whiskbrooms" and"Pushbrooms" Remote Sensing Platforms and Sensors  

E-Print Network [OSTI]

"Whiskbrooms" and"Pushbrooms" Remote Sensing Platforms and Sensors Remote sensing requires that a sensor be constructed and then attached to a platform that provides an aerial view of the landscape. "Whiskbrooms" and"Pushbrooms" Remote Sensing Platforms and Sensors Remote sensing requires that a sensor

Frank, Thomas D.

249

Remote computing using the National Fusion Grid  

Science Journals Connector (OSTI)

The National Fusion Collaboratory (http://www.fusiongrid.org) uses grid technology to implement remote computing on the National Fusion Grid. The motivations are to reduce the cost of computing resources, shorten the software deployment cycle, and simplify remote computing for the user community. The National Fusion Collaboratory has successfully demonstrated remote access as a grid service to the TRANSP transport analysis code for tokamak experiments. TRANSP development and administration are now centralized at the Princeton Plasma Physics Laboratory (PPPL), obviating both the need to port TRANSP to different platforms and the process of deploying TRANSP to remote sites. TRANSP users now share the resources of a powerful Linux cluster located at PPPL. Fusion researchers have completed over 900 TRANSP runs utilizing over 5600h of CPU time since the TRANSP service was installed in October 2002.

J.R Burruss; S Flanagan; K Keahey; C Ludescher; D.C McCune; Q Peng; L Randerson; D.P Schissel; M Thompson

2004-01-01T23:59:59.000Z

250

Radar remote sensing of the lower atmosphere  

E-Print Network [OSTI]

radar ducts over the Persian Gulf, J. Appl. Meteor. , vol.of the world. The Persian Gulf, the Mediterranean andifornia and 50% in the Persian Gulf [41]. Efforts in remote

Karimian, Ali

2012-01-01T23:59:59.000Z

251

Remote Sensing of Soils, Minerals, and Geomorphology  

E-Print Network [OSTI]

,Remote Sensing of Soils, Minerals, and GeomorphologyMinerals, and Geomorphology · Soil is unconsolidated material). ·· SoilSoil is unconsolidated material at the surface of the Earth thatis unconsolidated material

252

Satellite Remote Sensing in Offshore Wind Energy  

Science Journals Connector (OSTI)

Satellite remote sensing of ocean surface winds are presented with focus on wind energy applications. The history on operational and research-based satellite ocean wind mapping is briefly described for passive mi...

Charlotte Bay Hasager; Merete Badger; Poul Astrup

2013-01-01T23:59:59.000Z

253

2005 EPRI PowerPoint Template  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

x 7'd * Total weight - 80,000 lbs * Local Remote Control Outline of 69kV, 1000A, 1Ph Unit 7 2008 Electric Power Research Institute, Inc. All rights reserved. Program Team *...

254

Remote, condition-based maintenance for web-enabled robotic system  

Science Journals Connector (OSTI)

The current trends in industry include an integration of information and knowledge-base network with a manufacturing system, which coined a new term, e-manufacturing. From the perspective of e-manufacturing any production equipment and its control functions ... Keywords: Condition-based maintenance, Remote monitoring and operation, Robot availability

Yongjin (James) Kwon; Richard Chiou; Leonard Stepansky

2009-06-01T23:59:59.000Z

255

Secure Safety: Secure Remote Access to Critical Safety Systems in Offshore Installations  

Science Journals Connector (OSTI)

Safety Instrumented Systems (SIS) as defined in IEC 61508 and IEC 61511 are very important for the safety of offshore oil & natural gas installations. SIS typically include the Emergency Shutdown System (ESD) that ensures that process systems return ... Keywords: Offshore, Process Control, Safety Instrumented Systems, Secure remote access

Martin Gilje Jaatun; Tor Olav Grtan; Maria B. Line

2008-06-01T23:59:59.000Z

256

(DOE/EIS-0285/SA 118): Supplement Analysis for the Transmission System Vegetation Management Program EIS, Holcomb-Naselle 115kV)  

Broader source: Energy.gov (indexed) [DOE]

7, 2003 7, 2003 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-SA 118, Holcomb - Naselle 115 kV. James A. Jellison - TFO/Olympia Proposed Action: Vegetation Management along the Holcomb Naselle 115kV transmission line corridor from structure 1/1 through structure 21/10. Right of way width averages 100 feet. Location: The project area is located in Pacific County, Washington. Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes to remove unwanted vegetation along the right-of- way, access roads and around tower structures along the subject transmission line corridor. Approximately 21 miles of right-of-way will be treated using selective and non-selective

257

DOE/EA-1354; Environmental Assessment for the Fort Collins 115kV Transmission Line Upgrade Project (12/2001)  

Broader source: Energy.gov (indexed) [DOE]

ENVIRONMENTAL ASSESSMENT ENVIRONMENTAL ASSESSMENT FOR THE FORT COLLINS 115kV TRANSMISSION LINE UPGRADE PROJECT Prepared for: Platte River Power Authority and U.S. Department of Energy Western Area Power Administration DOE/EA 1354 September 2001 i TABLE OF CONTENTS SUMMARY ............................................................................................................... S-1 1.0 INTRODUCTION ...............................................................................................1-1 1.1 DESCRIPTION OF PROPOSED PROJECT .................................................................. 1-1 1.3 PURPOSE OF ENVIRONMENTAL ASSESSMENT....................................................

258

Testing of a 50 kA, 50 kV current interrupter with I sup 2 t preheating and long recovery voltage  

SciTech Connect (OSTI)

The Confinement Physics Research Facility (CPRF) presently being constructed at Los Alamos in a next generation Reversed Field Pinch (RFP) plasma experiment. An inductive energy transfer system, employing a 50 kA, 50 kV dc current interrupter, is being utilized for initiating the plasma current. These performance requirements (50 kA, 50 kV) had yet to be realized in a reliable switching system, development of this current interrupter system was initiated. A switch test bay with a 50 kA battery bank has been built at Los Alamos to test the interrupter in conditions which will exist in the CPRF experiment. Many switch parameters were measured to provide information on the current interrupting characteristics and reliability. Some of these diagnostics include voltage, current, pre and post I{sup 2}t contact resistance, opening speed and position, arc voltage, and stem temperature. To determine any long term changes, all shots and data channels are computer indexed, and may be easily recalled for review. Extensive testing was performed on Siemens D-10 vacuum interrupter. Test parameter space included 55 kA, 40 kV (per bottle); di/dt of 2250 A/{mu}s, I{sup 2}t of 5 {times} 10{sup 9} amp{sup 2} sec; and 20 kV-200 msec RC recovery decay. Circuit parameters effect opening reliability. Circuit data and the associated testing results will be presented along with long term trends of switch performance under normal'' conditions. 12 figs.

Reass, W.A.; Boenig, H.J.; Melton, J.G. (Los Alamos National Lab., NM (USA))

1989-01-01T23:59:59.000Z

259

2007 Urban Remote Sensing Joint Event Application of satellite Remote Sensing for Urban  

E-Print Network [OSTI]

2007 Urban Remote Sensing Joint Event Application of satellite Remote Sensing for Urban Risk Analysis: a case study of the 2003 extreme heat wave in Paris Bénédicte Dousset Hawaii Institute@ogs.trieste.it Abstract ­ Satellite observations are used to monitor the August 2003 heat wave in Paris

Paris-Sud XI, Université de

260

Overview of Remote Handling Equipment Used for the NPP A1 Decommissioning - 12141  

SciTech Connect (OSTI)

The first Czechoslovak NPP A1 was in operation from 1972 to 1977 and it was finally shutdown due to an accident (level 4 according to the INES). The presence of radioactive, toxic or hazardous materials limits personnel access to facilities and therefore it is necessary to use remote handling technologies for some most difficult characterization, retrieval, decontamination and dismantling tasks. The history of remote handling technologies utilization started in nineties when the spent nuclear fuel, including those fuel assemblies damaged during the accident, was prepared for the transport to Russia. Subsequent significant development of remote handling equipment continued during implementation of the NPP A1 decommissioning project - Stage I and ongoing Stage II. Company VUJE, Inc. is the general contractor for both mentioned stages of the decommissioning project. Various remote handling manipulators and robotics arms were developed and used. It includes remotely controlled vehicle manipulator MT-15 used for characterisation tasks in hostile and radioactive environment, special robust manipulator DENAR-41 used for the decontamination of underground storage tanks and multi-purposes robotics arms MT-80 and MT-80A developed for variety of decontamination and dismantling tasks. The heavy water evaporator facility dismantling is the current task performed remotely by robotics arm MT-80. The heavy water evaporator is located inside the main production building in the room No. 220 where loose surface contamination varies from 10 Bq/cm{sup 2} to 1x10{sup 3} Bq/cm{sup 2}, dose rate is up to 1.5 mGy/h and the feeding pipeline contained liquid RAW with high tritium content. Presented manipulators have been designed for broad range of decommissioning tasks. They are used for recognition, sampling, waste retrieval from large underground tanks, decontamination and dismantling of technological equipments. Each of the mentioned fields claims specific requirements on design of manipulator, their operation and control systems as well as tools of manipulators. Precise planning of decontamination and dismantling tasks is necessary for its successful performance by remotely controlled manipulator. The example of the heavy water evaporator demonstrates typical procedure for decommissioning of contaminated technological equipment by remotely controlled manipulators - planning of decommissioning tasks, preparatory tasks, modification of applied tools and design of specific supporting constructions for manipulator and finally decontamination and dismantling themselves. Due to the particularly demanding conditions in highly contaminated A1 NPP, a team of experts with special know-how in the field of decommissioning has grown up, and unique technological equipment enabling effective and safe work in environment with a high radiation level has been developed. (authors)

Kravarik, K.; Medved, J.; Pekar, A.; Stubna, M. [VUJE, Inc., Okruzna 5, 918 64 Trnava (Slovakia); Michal, V. [IAEA, Wagramer Strasse 5, P.O.Box 100, A-1400 Vienna (Austria); Vargovcik, L. [ZTS VVU Kosice, Inc., Juzna Trieda 95, 041 24 Kosice (Slovakia)

2012-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "kv remote control" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Remote inspection system for hazardous sites  

SciTech Connect (OSTI)

Long term storage of special nuclear materials poses a number of problems. One of these is a need to inspect the items being stored from time to time. Yet the environment is hostile to man, with significant radiation exposure resulting from prolonged presence in the storage facility. This paper describes research to provide a remote inspection capability, which could lead to eliminating the need for humans to enter a nuclear storage facility. While there are many ways in which an RI system might be created, this paper describes the development of a prototype remote inspection system, which utilizes virtual reality technology along with robotics. The purpose of this system is to allow the operator to establish a safe and realistic telepresence in a remote environment. In addition, it was desired that the user interface for the system be as intuitive to use as possible, thus eliminating the need for extensive training. The goal of this system is to provide a robotic platform with two cameras, which are capable of providing accurate and reliable stereographic images of the remote environment. One application for the system is that it might be driven down the corridors of a nuclear storage facility and utilized to inspect the drums inside, all without the need for physical human presence. Thus, it is not a true virtual reality system providing simulated graphics, but rather an augmented reality system, which performs remote inspection of an existing, real environment.

Redd, J.; Borst, C.; Volz, R.A.; Everett, L.J. [Texas A and M Univ., College Station, TX (United States). Computer Science Dept.] [Texas A and M Univ., College Station, TX (United States). Computer Science Dept.

1999-04-01T23:59:59.000Z

262

Definition: Remote Service Switch | Open Energy Information  

Open Energy Info (EERE)

Service Switch Service Switch Jump to: navigation, search Dictionary.png Remote Service Switch A power switch within a smart meter that allows a utility to turn electrical service to a residential customer premise on or off. The switch is remotely operated from the utility using the AMI communications infrastructure. This feature is limited to residential meters providing 200 amp service or less, and allows a utility to quickly switch service without having to roll a service truck. This can be particularly useful for reducing service time and associated costs for establishing or terminating services for move-ins/move-outs, or for switching off service for safety reasons.[1] Related Terms advanced metering infrastructure References ↑ https://www.smartgrid.gov/category/technology/remote_service_switch

263

Elements of an advanced integrated operator control station  

SciTech Connect (OSTI)

One of the critical determinants of peformance for any remotely operated maintenance system is the compatibility achieved between elements of the man/machine interface (e.g., master manipulator controller, controls, displays, etc.) and the human operator. In the Remote Control Engineering task of the Consolidated Fuel Reprocessing Program, considerable attention has been devoted to optimizing the man/machine interface of the operator control station. This system must be considered an integral element of the overall maintenance work system which includes transporters, manipulators, remote viewing, and other parts. The control station must reflect the integration of the operator team, control/display panels, manipulator master controllers, and remote viewing monitors. Human factors principles and experimentation have been used in the development of an advanced integrated operator control station designed for the advance servomanipulator. Key features of this next-generation design are summarized in this presentation. 7 references, 4 figures.

Clarke, M.M.; Kreifeldt, J.G.

1984-01-01T23:59:59.000Z

264

Elements of an advanced integrated operator control station  

SciTech Connect (OSTI)

One of the critical determinants of performance for any remotely operated maintenance system is the compatibility achieved between elements of the man/machine interface (e.g., master manipulator controller, controls, displays) and the human operator. In the remote control engineering task of the Consolidated Fuel Reprocessing Program, considerable attention has been devoted to optimizing the man/machine interface of the operator control station. This system must be considered an integral element of the overall maintenance work system which includes transporters, manipulators, remote viewing, and other parts. The control station must reflect the integration of the operator team, control/display panels, manipulator master controllers, and remote viewing monitors. Human factors principles and experimentation have been used in the development of an advanced integrated operator control station designed for the advance servomanipulator. Key features of this next-generation design are summarized in this presentation. 7 references, 4 figures.

Clarke, M.M.; Kreifeldt, J.G.

1984-01-01T23:59:59.000Z

265

Innovative Control of Electric Heat in Multifamily Buildings  

E-Print Network [OSTI]

This paper describes the application of web-based wireless technology for control of electric heating in a large multifamily housing complex. The control system architecture and components are described. A web-based application enables remote...

Lempereur, D.; Bobker, M.

2004-01-01T23:59:59.000Z

266

Photovoltaic applications for remote-island needs  

SciTech Connect (OSTI)

Electric power supply options available to many of the central and south Pacific island governments are severely constrained by remoteness, limited infrastructures, a corrosive natural environment, and the high delivered costs of many conventional energy sources. Photovoltaic energy systems offer a currently available, practical, and cost-effective source of electricity for many stand-alone applications in remote areas of the Pacific. Photovoltaic system definitions and cost analyses are provided for selected applications in the Republic of Palau, the Federated States of Micronesia, the Republic of the Marshall Islands, and the Territory of American Samoa.

Schaller, D.A.

1983-01-01T23:59:59.000Z

267

Category:Remote Sensing Techniques | Open Energy Information  

Open Energy Info (EERE)

Remote Sensing Techniques Remote Sensing Techniques Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Geothermalpower.jpg Looking for the Remote Sensing Techniques page? For detailed information on remote sensing techniques used as a geothermal exploration technique, click here. Category: Remote Sensing Techniques Add.png Add a new Remote Sensing Technique Subcategories This category has the following 2 subcategories, out of 2 total. A [+] Active Sensors‎ (1 categories) 2 pages P [×] Passive Sensors‎ 13 pages Pages in category "Remote Sensing Techniques" The following 2 pages are in this category, out of 2 total. A Active Sensors L Long-Wave Infrared Retrieved from "http://en.openei.org/w/index.php?title=Category:Remote_Sensing_Techniques&oldid=594055"

268

Remote Sensing for Biodiversity Conservation of the Albertine Rift  

E-Print Network [OSTI]

183 10 Remote Sensing for Biodiversity Conservation of the Albertine Rift in Eastern Africa Samuel of biodiversity conservation is understanding how environmental factors influence species abundance 2003). The rapidly developing field of remote sensing has been invaluable to biodiversity conservation

Wang, Y.Q. "Yeqiao"

269

Geothermal Exploration Using Aviris Remote Sensing Data Over...  

Open Energy Info (EERE)

Aviris Remote Sensing Data Over Fish Lake Valley, Nv Jump to: navigation, search OpenEI Reference LibraryAdd to library Conference Paper: Geothermal Exploration Using Aviris Remote...

270

First Oak Ridge Remote-Handled Transuranic Waste Shipment Arrives...  

Broader source: Energy.gov (indexed) [DOE]

First Oak Ridge Remote-Handled Transuranic Waste Shipment Arrives Safely at WIPP First Oak Ridge Remote-Handled Transuranic Waste Shipment Arrives Safely at WIPP March 2, 2009 -...

271

V-149: Microsoft Internet Explorer Object Access Bug Lets Remote...  

Broader source: Energy.gov (indexed) [DOE]

CDwnBindInfo Object Reuse Flaw Lets Remote Users Execute Arbitrary Code U-047: Siemens Automation License Manager Bugs Let Remote Users Deny Service or Execute Arbitrary Code...

272

Tools for remote collaboration on the DIII-D National Fusion Facility  

Science Journals Connector (OSTI)

The DIII-D National Fusion Facility, a tokamak experiment funded by the US Department of Energy and operated by General Atomics (GA), is an international resource for plasma physics and fusion energy science research. This facility has a long history of collaborations with scientists from a wide variety of laboratories and universities from around the world. That collaboration has mostly been conducted by travel to and participation at the DIII-D site. Many new developments in the computing and technology fields are now facilitating collaboration from remote sites, thus reducing some of the needs to travel to the experiment. Some of these developments include higher speed wide area networks, powerful workstations connected within a distributed computing environment, network based audio/video capabilities, and the use of the world wide web. As the number of collaborators increases, the need for remote tools become important options to efficiently utilize the DIII-D facility. In the last two years a joint study by GA, Princeton Plasma Physics Laboratory (PPPL), Lawrence Livermore National Laboratory (LLNL), and Oak Ridge National Laboratory (ORNL) has introduced remote collaboration tools into the DIII-D environment and studied their effectiveness. These tools have included the use of audio/video for communication from the DIII-D control room, the broadcast of meetings, use of inter-process communication software to post events to the network during a tokamak shot, the creation of a DCE (distributed computing environment) cell for creating a common collaboratory environment, distributed use of computer cycles, remote data access, and remote display of results. This study also included sociological studies of how scientists in this environment work together as well as apart. As a result of these studies, there is now in place an automated distributed processing environment connected to the real-time experimental operations which can be joined by users at remote locations. This environment will allow further exploration of the technology and sociology of remote participation in the DIII-D program. Having the tools in place has already permitted remote participation in DIII-D experiments that would not have occurred otherwise, and thus the introduction of these tools has shown the initial feasibility of increasing and improving remote collaboration.

B.B. McHarg Jr; T.A. Casper; S. Davis; D. Greenwood

1999-01-01T23:59:59.000Z

273

Equipment for Anti- Electricity Stealing with Remote Monitoring  

E-Print Network [OSTI]

AbstractThe power theft monitoring is an important research in electric power system, and electricity-stealing prevention became a big problem to the electricity board. based on the kind of electricity-stealing and actual demand of prevention of stealing electricity, the equipment of electricity-stealing with remote monitoring is designed, with PIC microcontroller as the control core. In this the standard energy meter and user energy meter are used to calculate and judge whether electricity-stealing happen or not. Results of the user application show that the system not only realizes monitoring the behavior of electricity stealing, accurately recording the time of electricity-stealing occur and finish, the quantity of electricity-stealing and sends the information to the area field man through SMS to detect the electricity-stealer, but also realizes the behavior of electricity-stealing with remote monitoring, which is convenient for centralized management.In addition, the system offers a solving method to the data of meter reading.

Mr. Sudheer K. Reddy; Mr. Musthafa. P; Mr. K. Sakthidhasan

274

T-690: Check Point Endpoint Security On-Demand Client Lets Remote Users  

Broader source: Energy.gov (indexed) [DOE]

0: Check Point Endpoint Security On-Demand Client Lets Remote 0: Check Point Endpoint Security On-Demand Client Lets Remote Users Execute Arbitrary Code T-690: Check Point Endpoint Security On-Demand Client Lets Remote Users Execute Arbitrary Code August 10, 2011 - 8:45am Addthis PROBLEM: Due to quality issues within the software, an attacker is able to access insecure methods from the "trustworthy" Java applet or ActiveX control and exploit those features to compromise all client systems that trust the correctly signed Java applet or ActiveX control (e.g. all users that need to use this software for accessing internal systems over company VPN). PLATFORM: Multiple products:- R65.70 - R70.40 - R71.30 - R75 - Connectra R66.1 - Connectra R66.1n - VSX R65.20 - VSX R67 ABSTRACT: Check Point Endpoint Security On-Demand Client Lets Remote Users Execute

275

Do visualizations improve synchronous remote collaboration?  

Science Journals Connector (OSTI)

Information visualizations can improve collaborative problem solving, but this improvement may depend on whether visualizations promote communication. In an experiment on the effect of network visualizations, remote pairs worked synchronously to identify ... Keywords: collaboration, communication, cscw, distributed work, empirical studies, information visualization

Aruna D. Balakrishnan; Susan R. Fussell; Sara Kiesler

2008-04-01T23:59:59.000Z

276

REFERENCE: Introduction to Remote Sensing. James B.  

E-Print Network [OSTI]

Temperature #12;ACTIVE REMOTE SENSING The sensor illuminates the terrain with its own energy, then records the reflected energy as it has been altered by the earth's surface. #12;SIDE-LOOKING AIRBORNE RADAR SLAR #12 JUAN VENICE #12;EARTH TOPOGRAPHY USING MULTISPECTRAL SCANNERS MT. PINATUBO MT. EVEREST #12;APPLICATIONS

Gilbes, Fernando

277

Bulk Power System Dynamics and Control IV -Restructuring, August 24-28, Santorini, Greece. Improving Pacific Inter-tie Stability Using  

E-Print Network [OSTI]

, and C) Slatt TCSC (on the Slatt-Buckley 500 kV line); and 2) to design robust controls@eecs.wsu.edu Transmission Operations and Planning Bonneville Power Administration Vancouver, WA 98666-0491 Abstract voltage control needs for the stability support of COI lines in the Pacific Northwest system. The proposed

Venkatasubramanian, Mani V.

278

Training program requirements for remote equipment operators in nuclear facilities  

SciTech Connect (OSTI)

One of the most neglected areas in the engineering development of remotely operated equipment applications in nuclear environments is the planning of adequate training programs for the equipment operators. Remote equipment accidents cannot be prevented solely by engineered safety features on the equipment. As a result of the experiences in using remote equipment in the recovery effort at Three Mile Island Unit 2 (TMI-2), guidelines for the development of remote equipment operator training programs have been generated. The result is that a successful education and training program can create an environment favorable to the safe and effective implementation of a remote equipment program in a nuclear facility.

Palau, G.L.; Auclair, K.D.

1986-01-01T23:59:59.000Z

279

Reliability review of the remote tool delivery system locomotor  

SciTech Connect (OSTI)

The locomotor being built by RedZone Robotics is designed to serve as a remote tool delivery (RID) system for waste retrieval, tank cleaning, viewing, and inspection inside the high-level waste tanks 8D-1 and 8D-2 at West Valley Nuclear Services (WVNS). The RTD systm is to be deployed through a tank riser. The locomotor portion of the RTD system is designed to be inserted into the tank and is to be capable of moving around the tank by supporting itself and moving on the tank internal structural columns. The locomotor will serve as a mounting platform for a dexterous manipulator arm. The complete RTD system consists of the locomotor, dexterous manipulator arm, cameras, lights, cables, hoses, cable/hose management system, power supply, and operator control station.

Chesser, J.B.

1999-04-01T23:59:59.000Z

280

V-120: EMC Smarts Network Configuration Manager Java RMI Access Control  

Broader source: Energy.gov (indexed) [DOE]

0: EMC Smarts Network Configuration Manager Java RMI Access 0: EMC Smarts Network Configuration Manager Java RMI Access Control Flaw Lets Remote Users Gain Full Control V-120: EMC Smarts Network Configuration Manager Java RMI Access Control Flaw Lets Remote Users Gain Full Control March 27, 2013 - 12:51am Addthis PROBLEM: EMC Smarts Network Configuration Manager Java RMI Access Control Flaw Lets Remote Users Gain Full Control PLATFORM: Version(s): prior to 9.2 ABSTRACT: Two vulnerabilities were reported in EMC Smarts Network Configuration Manager. REFERENCE LINKS: SecurityTracker Alert ID: 1028342 www.emc.com CVE-2013-0935 IMPACT ASSESSMENT: Medium DISCUSSION: A remote user can access some Java Remote Method Invocation methods without authenticating to gain control of the target system. A user can exploit unspecified flaws in the NCM System Management

Note: This page contains sample records for the topic "kv remote control" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

V-120: EMC Smarts Network Configuration Manager Java RMI Access Control  

Broader source: Energy.gov (indexed) [DOE]

0: EMC Smarts Network Configuration Manager Java RMI Access 0: EMC Smarts Network Configuration Manager Java RMI Access Control Flaw Lets Remote Users Gain Full Control V-120: EMC Smarts Network Configuration Manager Java RMI Access Control Flaw Lets Remote Users Gain Full Control March 27, 2013 - 12:51am Addthis PROBLEM: EMC Smarts Network Configuration Manager Java RMI Access Control Flaw Lets Remote Users Gain Full Control PLATFORM: Version(s): prior to 9.2 ABSTRACT: Two vulnerabilities were reported in EMC Smarts Network Configuration Manager. REFERENCE LINKS: SecurityTracker Alert ID: 1028342 www.emc.com CVE-2013-0935 IMPACT ASSESSMENT: Medium DISCUSSION: A remote user can access some Java Remote Method Invocation methods without authenticating to gain control of the target system. A user can exploit unspecified flaws in the NCM System Management

282

College of Engineering and Architecture Evolution of Control for the  

E-Print Network [OSTI]

HVDC 3 HVDC 1 500kV AC 2 parallel 500 kV AC 1 HVDC Tibet #12;College of Engineering and Architecture

283

Remote/New sites: Many Field  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Remote/New sites: Many Field Remote/New sites: Many Field Campaigns require temporary installations on non-ACRF sites. This requires identification of landowners, negotiation of leases, and infrastructure logistics for electrical and internet connectivity. Argonne National Laboratory is managed by UChicago-Argonne LLC for the U.S. Department of Energy SGP Field Campaigns: The Other Side of Operations Brad W. Orr 1 Dan J. Rusk 2 John Schatz 2 Dan Nelson 2 David Breedlove 2 Douglas L. Sisterson 1 1 Argonne National Laboratory, Argonne, IL 2 ACRF/SGP, Cherokee Nation Distributors, Stilwell, OK Background Implementation All departments must work closely together to implement a campaign. In addition they must have the flexibility to adapt to new and unique instrument deployments. The

284

Information compression for remote readable ID tags  

Science Journals Connector (OSTI)

Optical identity (ID) tags have been introduced and described to achieve remote target recognition and identification. Optical ID tags usually contain encrypted signatures to be read out, decrypted and verified. In this paper, new features are introduced so that ID tags can be reliably used for remote detection and verification even if the captured tag is extremely degraded by perspective or optical distortion. Optimization of the ID tag size as well as the number of bits required to display the complex-amplitude information are analysed and discussed. The highest compression of grey levels, which corresponds to binary ID tags, is studied. Decryption and verification results are provided to analyse the possibilities of the newly designed optical ID tags.

Sergi Horrillo; Elisabet Prez-Cabr; Mara S Milln

2010-01-01T23:59:59.000Z

285

Remotely deployable aerial inspection using tactile sensors  

SciTech Connect (OSTI)

For structural monitoring applications, the use of remotely deployable Non-Destructive Evaluation (NDE) inspection platforms offer many advantages, including improved accessibility, greater safety and reduced cost, when compared to traditional manual inspection techniques. The use of such platforms, previously reported by researchers at the University Strathclyde facilitates the potential for rapid scanning of large areas and volumes in hazardous locations. A common problem for both manual and remote deployment approaches lies in the intrinsic stand-off and surface coupling issues of typical NDE probes. The associated complications of these requirements are obviously significantly exacerbated when considering aerial based remote inspection and deployment, resulting in simple visual techniques being the preferred sensor payload. Researchers at Bristol Robotics Laboratory have developed biomimetic tactile sensors modelled on the facial whiskers (vibrissae) of animals such as rats and mice, with the latest sensors actively sweeping their tips across the surface in a back and forth motion. The current work reports on the design and performance of an aerial inspection platform and the suitability of tactile whisking sensors to aerial based surface monitoring applications.

MacLeod, C. N.; Cao, J.; Pierce, S. G.; Dobie, G.; Summan, R. [Centre for Ultrasonic Engineering, University of Strathclyde, Glasgow, G1 1XW (United Kingdom); Sullivan, J. C.; Pipe, A. G. [Bristol Robotics Laboratory, University of the West of England, Bristol, BS16 1QY (United Kingdom)

2014-02-18T23:59:59.000Z

286

Welding Robot and Remote Handling System for the Yucca Mountain Waste Package Closure System  

SciTech Connect (OSTI)

In preparation for the license application and construction of a repository for housing the nation's spent nuclear fuel and high-level waste in Yucca Mountain, the Idaho National Laboratory (INL) has been charged with preparing a mock-up of a full-scale prototype system for sealing the waste packages (WP). Three critical pieces of the closure room include two PaR Systems TR4350 Telerobotic Manipulators and a PaR Systems XR100 Remote Handling System (RHS). The TR4350 Manipulators are 6-axis programmable robots that will be used to weld the WP lids and purge port cap as well as conduct nondestructive examinations. The XR100 Remote Handling System is a 4-axis programmable robot that will be used to transport the WP lids and process tools to the WP for operations and remove equipment for maintenance. The welding and RHS robots will be controlled using separate PaR 5/21 CIMROC Controllers capable of complex motion control tasks. A tele-operated PaR 4350 Manipulator will also be provided with the XR100 Remote Handling System. It will be used for maintenance and associated activities within the closure room. (authors)

Barker, M.E.; Holt, T.E.; LaValle, D.R. [PaR Systems, Inc., Shoreview, MN (United States); Pace, D.P.; Croft, K.M.; Shelton-Davis, C.V. [Battelle Energy Alliance, LLC/Idaho National Laboratory, Idaho Falls, ID (United States)

2008-07-01T23:59:59.000Z

287

T-616: PHP Stream Component Remote Denial of Service Vulnerability |  

Broader source: Energy.gov (indexed) [DOE]

6: PHP Stream Component Remote Denial of Service Vulnerability 6: PHP Stream Component Remote Denial of Service Vulnerability T-616: PHP Stream Component Remote Denial of Service Vulnerability May 5, 2011 - 12:59am Addthis PROBLEM: PHP Stream Component Remote Denial of Service Vulnerability PLATFORM: Ubuntu Linux PHP MandrakeSoft Corporate Server MandrakeSoft Enterprise Server MandrakeSoft Linux Mandrake ABSTRACT: PHP is prone to a remote denial-of-service vulnerability because the proxy server fails to handle certain FTP requests. An attacker can exploit this issue to crash the affected application, denying service to legitimate users. Versions prior to PHP 5.3.6 are vulnerable. reference LINKS: SecurityFocus IMPACT ASSESSMENT: Medium Discussion: PHP is prone to a remote denial-of-service vulnerability because the proxy server fails to handle certain FTP requests. An attacker can exploit this

288

U-161: Citrix Provisioning Services Unspecified Flaw Lets Remote Users  

Broader source: Energy.gov (indexed) [DOE]

1: Citrix Provisioning Services Unspecified Flaw Lets Remote 1: Citrix Provisioning Services Unspecified Flaw Lets Remote Users Execute Arbitrary Code U-161: Citrix Provisioning Services Unspecified Flaw Lets Remote Users Execute Arbitrary Code May 3, 2012 - 7:00am Addthis PROBLEM: Citrix Provisioning Services Unspecified Flaw Lets Remote Users Execute Arbitrary Code PLATFORM: 6.1 and prior ABSTRACT: A vulnerability was reported in Citrix Provisioning Services. A remote user can execute arbitrary code on the target system. reference LINKS: SecurityTracker Alert ID: 1027004 Secunia Advisory SA48971 Citrix advisory IMPACT ASSESSMENT: Medium Discussion: A remote user can send a specially crafted packet to trigger an unspecified flaw and execute arbitrary code on the target system. The code will run with the privileges of the target service.

289

Curecanti-Blue Mesa-Salida 115-kV transmission lines access roads rehabilitation, maintenance, and construction project. Environmental Assessment  

SciTech Connect (OSTI)

Western Area Power Administration (Western) is a power marketing agency of the US Department of Energy, with jurisdiction in 15 western states. The Salt Lake City Area (SLCA) of Western performs the agency`s mission in parts of Colorado, New Mexico, Texas, Utah, Arizona, Wyoming, and Nevada. As part of its mission, Western owns, operates, and maintains a system of transmission lines for transmitting bulk electrical energy from points of generation to and between delivery points. Part of that system in southwestern Colorado includes the Blue Mesa-Curecanti and Blue Mesa-Salida 115-kV transmission lines. Western proposes to conduct maintenance and improve its access roads for these two transmission lines. This paper discusses the impacts to the existing environment as well as the environmental consequences resulting from the maintenance and construction that is proposed.

Not Available

1993-07-01T23:59:59.000Z

290

Environmental Assessment and Finding of No Significant Impact: Curecanti-Lost Canyon 230-kV Transmission Line Reroute Project, Montrose County, Colorado  

SciTech Connect (OSTI)

The Department of Energy (DOE), Western Area Power Administration (Western) is proposing to reroute a section of the Curecanti-Lost Canyon 230-kilovolt (kV) transmission line, in Montrose County, Colorado. A portion of the transmission line, situated 11 miles southeast of Montrose, Colorado, crosses Waterdog Peak, an area of significant geologic surface activity, which is causing the transmission line's lattice steel towers to shift. This increases stress to structure hardware and conductors, and poses a threat to the integrity of the transmission system. Western proposes to relocate the lattice steel towers and line to a more geologically stable area. The existing section of transmission line and the proposed relocation route cross Bureau of Land Management and private land holdings.

N /A

2000-03-20T23:59:59.000Z

291

ESS 2012 Peer Review - 15 kV Phase Leg Power Modules with SiC Devices - Ranbir Singh, GeneSiC Semiconductor  

Broader source: Energy.gov (indexed) [DOE]

1 1 Click to edit Master title style 15 kV Phase Leg Power Modules with SiC MIDSJT Devices Ranbir Singh and Siddarth Sundaresan GeneSiC Semiconductor Inc. ranbir.singh@genesicsemi.com +1 703 996 8200 43670 Trade Center Pl #155; Dulles VA 20166 September 27, 2012 Acknowledgement: The authors thank Dr. Imre Gyuk for funding this work and Dr. Stan Atcitty for technical supervision Sandia National Laboratories is a multi- program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000. DOE SBIR HV DC Link Grant #SC0008240 2 Phase Leg forms fundamental building block for AC/DC AND DC/AC Conversion

292

V-055: Firefly Media Server Null Pointer Dereference Lets Remote...  

Broader source: Energy.gov (indexed) [DOE]

V-055: Firefly Media Server Null Pointer Dereference Lets Remote Users Deny Service December 26, 2012 - 9:00am Addthis PROBLEM: Firefly Media Server Null Pointer Dereference...

293

V-150: Apache VCL Input Validation Flaw Lets Remote Authenticated...  

Broader source: Energy.gov (indexed) [DOE]

or userGrant) can send specially crafted data via the web interface or XMLRPC API to gain additional administrative privileges. IMPACT: A remote authenticated user can...

294

Alternative Carriers For Remote Renewable Energy Sources Using...  

Open Energy Info (EERE)

the economic, technical, and environmental viability of converting remote renewable energy to fuel for transport using existing CNG pipelines, and to compare this alternative...

295

Use Remote Sensing Data (selected visible and infrared spectrums...  

Broader source: Energy.gov (indexed) [DOE]

Use Remote Sensing Data (selected visible and infrared spectrums) to locate high temperature ground anomalies in Colorado. Confirm heat flow potential with on-site surveys to drill...

296

Application Of Remote Sensing To Geothermal Prospecting | Open...  

Open Energy Info (EERE)

navigation, search OpenEI Reference LibraryAdd to library Journal Article: Application Of Remote Sensing To Geothermal Prospecting Abstract This paper presents a summary of a...

297

Active and Passive Remote Sensing Diagram | Open Energy Information  

Open Energy Info (EERE)

Diagram Jump to: navigation, search OpenEI Reference LibraryAdd to library Web Site: Active and Passive Remote Sensing Diagram Author National Aeronautics and Space Administration...

298

U-219: Symantec Web Gateway Input Validation Flaws Lets Remote...  

Broader source: Energy.gov (indexed) [DOE]

9: Symantec Web Gateway Input Validation Flaws Lets Remote Users Inject SQL Commands, Execute Arbitrary Commands, and Change User Passwords U-219: Symantec Web Gateway Input...

299

Community Energy Planning A Resource Guide for Remote Communities...  

Open Energy Info (EERE)

Guide for Remote Communities in Canada AgencyCompany Organization Natural Resources Canada Sector Energy, Land Focus Area Energy Efficiency - Central Plant, Energy...

300

Remote Laser Diffraction Particle Size Distribution Analyzer  

SciTech Connect (OSTI)

In support of a radioactive slurry sampling and physical characterization task, an off-the-shelf laser diffraction (classical light scattering) particle size analyzer was utilized for remote particle size distribution (PSD) analysis. Spent nuclear fuel was previously reprocessed at the Idaho Nuclear Technology and Engineering Center (INTECformerly recognized as the Idaho Chemical Processing Plant) which is on DOEs INEEL site. The acidic, radioactive aqueous raffinate streams from these processes were transferred to 300,000 gallon stainless steel storage vessels located in the INTEC Tank Farm area. Due to the transfer piping configuration in these vessels, complete removal of the liquid can not be achieved. Consequently, a heel slurry remains at the bottom of an emptied vessel. Particle size distribution characterization of the settled solids in this remaining heel slurry, as well as suspended solids in the tank liquid, is the goal of this remote PSD analyzer task. A Horiba Instruments Inc. Model LA-300 PSD analyzer, which has a 0.1 to 600 micron measurement range, was modified for remote application in a hot cell (gamma radiation) environment. This technology provides rapid and simple PSD analysis, especially down in the fine and microscopic particle size regime. Particle size analysis of these radioactive slurries down in this smaller range was not previously achievablemaking this technology far superior than the traditional methods used. Successful acquisition of this data, in conjunction with other characterization analyses, provides important information that can be used in the myriad of potential radioactive waste management alternatives.

Batcheller, Thomas Aquinas; Huestis, Gary Michael; Bolton, Steven Michael

2001-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "kv remote control" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Remote vacuum compaction of compressible hazardous waste  

DOE Patents [OSTI]

A system for remote vacuum compaction and containment of low-level radioactive or hazardous waste comprising a vacuum source, a sealable first flexible container, and a sealable outer flexible container for receiving one or more first flexible containers. A method for compacting low level radioactive or hazardous waste materials at the point of generation comprising the steps of sealing the waste in a first flexible container, sealing one or more first containers within an outer flexible container, breaching the integrity of the first containers, evacuating the air from the inner and outer containers, and sealing the outer container shut.

Coyne, Martin J. (Pittsburgh, PA); Fiscus, Gregory M. (McMurray, PA); Sammel, Alfred G. (Pittsburgh, PA)

1998-01-01T23:59:59.000Z

302

Remote vacuum compaction of compressible hazardous waste  

DOE Patents [OSTI]

A system is described for remote vacuum compaction and containment of low-level radioactive or hazardous waste comprising a vacuum source, a sealable first flexible container, and a sealable outer flexible container for receiving one or more first flexible containers. A method for compacting low level radioactive or hazardous waste materials at the point of generation comprising the steps of sealing the waste in a first flexible container, sealing one or more first containers within an outer flexible container, breaching the integrity of the first containers, evacuating the air from the inner and outer containers, and sealing the outer container shut. 8 figs.

Coyne, M.J.; Fiscus, G.M.; Sammel, A.G.

1998-10-06T23:59:59.000Z

303

Tank Remote Repair System Conceptual Design  

SciTech Connect (OSTI)

This document describes two conceptual designs for a Tank Remote Repair System to perform leak site repairs of double shell waste tank walls (Types I, II, III, and IIIA) from the annulus space. The first concept uses a magnetic wall crawler and an epoxy patch system and the second concept uses a magnetic wall crawler and a magnetic patch system. The recommended concept uses the magnetic patch system, since it is simpler to deliver, easier to apply, and has a higher probability of stopping an active leak.

Kriikku, E.

2002-12-06T23:59:59.000Z

304

ImageCat, Inc. Remote Sensing for PostRemote Sensing for Post--disasterdisaster  

E-Print Network [OSTI]

to Salt Lake City SAR simulation The way forward #12;ImageCat, Inc. The IdeaThe Idea Remote sensing and non-damaged structures #12;ImageCat, Inc. Application to Salt Lake CityApplication to Salt Lake City 0 AssessmentBridge Damage Assessment Beverley J. Adams Ph.D. Charles K. Huyck Sungbin Cho Ronald T. Eguchi

Shinozuka, Masanobu

305

Securing Remote Desktop for Windows XP http://www.mobydisk.com/./techres/securing_remote_desktop.html  

E-Print Network [OSTI]

an account lockout policy #12;There are already tools that will use brute-force to guess passwords and log-on remotely. You cannot stop this, but it can be minimized by setting an account lockout policy. If someone system. From the same Local Security Policy screen from before, go to Account Policies - Account Lockout

Major, Arkady

306

Remote Sens. 2011, 3, 343-361; doi:10.3390/rs3020343 Remote Sensing  

E-Print Network [OSTI]

; solar irradiance; solar exposure; climate; Africa; Europe; Atlantic Ocean; remote sensing; long.mdpi.com/journal/remotesensing Article The HelioClim Project: Surface Solar Irradiance Data for Climate Applications Philippe Blanc, Benoît Gschwind, Mireille Lefèvre and Lucien Wald * Center for Energy and Processes, MINES ParisTech, BP

Paris-Sud XI, Université de

307

Feasibility of thyristor controlled series capacitor for distribution substation enhancements  

SciTech Connect (OSTI)

While Thyristor Controlled Series Capacitors (TCSCs) are already being used for control of transmission system power flows, the dynamic adjustment of transmission infeed impedances presents other system enhancement opportunities. In the case of the Con Edison system, distributing substation upgrades are severely constrained by limits to existing circuit breaker interrupting capabilities. Because additional transmission line infeeds cannot be provided without increasing fault current levels, a TCSC was investigated for use as a fault current limiter. In order to demonstrate proper operation in the current limiting mode, Electromagnetic Transients Program (EMTP) simulations were conducted. Three TCSC configurations are presented to illustrate that additional power can be provided during normal operation without increasing fault currents at the substation: (1) series compensation of existing 138 kV infeeds (to allow higher substation MVA uprates), (2) series compensation of new 138 kV infeeds (without fault current increases), and (3) a 13.8 kV TCSC compensated link between two substations (to allow regulated power transfer between substation buses).

Godart, T.F.; Imece, A.F.; McIver, J.C. [GE Industrial and Power Systems, Schenectady, NY (United States). Power Systems Engineering Dept.; Chebli, E.A. [Consolidated Edison Co. of NY, Inc., New York, NY (United States)

1994-12-31T23:59:59.000Z

308

Feasibility of thyristor controlled series capacitor for distribution substation enhancements  

SciTech Connect (OSTI)

While Thyristor Controlled Series Capacitors (TCSCs) are already being used for control of transmission system power flows, the dynamic adjustment of transmission infeed impedances presents other system enhancement opportunities. In the case of the Con Edison system, distribution substation upgrades are severely constrained by limits to existing circuit breaker interrupting capabilities. Because additional transmission line infeeds cannot be provided without increasing fault current levels, a TCSC was investigated for use as a fault current limiter. In order to demonstrate proper operation in the current limiting mode, Electromagnetic Transients Program (EMTP) simulations were conducted. Three TCSC configurations are presented to illustrate that additional power can be provided during normal operation without increasing fault currents at the substation: (1) series compensation of existing 138 kV infeeds (to allow higher substation MVA uprates), (2) series compensation of new 138 kV infeeds (without fault current increases), and (3) a 13.8 kV TCSC compensated link between two substations (to allow regulated power transfer between substation buses).

Godart, T.F.; Imece, A.F.; McIver, J.C. [GE Industrial and Power Systems, Schenectady, NY (United States). Power Systems Engineering Dept.] [GE Industrial and Power Systems, Schenectady, NY (United States). Power Systems Engineering Dept.; Chebli, E.A. [Consolidated Edison Co. of New York Inc., New York, NY (United States)] [Consolidated Edison Co. of New York Inc., New York, NY (United States)

1995-01-01T23:59:59.000Z

309

Restoration and testing of an HTS fault current controller  

SciTech Connect (OSTI)

A three-phase, 1200 A, 12.5 kV fault current controller using three HTS 4 mH coils, was built by industry and tested in 1999 at the Center Substation of Southern California Edison in Norwalk, CA. During the testing, it appeared that each of the three single-phase units had experienced a voltage breakdown, one externally and two internally. Los Alamos National Laboratory (LANL) was asked by DOE to restore the operation of the fault current controller provided the HTS coils had not been damaged during the initial substation tests. When the internally-failed coil vacuum vessels were opened it became evident that in these two vessels, a flashover had occurred at the high voltage bus section leading to the terminals of the superconducting coil. An investigation into the failure mechanism resulted in six possible causes for the flashover. Based on these causes, the high voltage bus was completely redesigned. Single-phase tests were successfully performed on the modified unit at a 13.7 kV LANL substation. This paper presents the postulated voltage flashover failure mechanisms, the new high voltage bus design which mitigates the failure mechanisms, the sequence of tests used to validate the new design, and finally, the results of variable load and short-circuit tests with the single-phase unit operating on the LANL 13.7 kV substation.

Waynert, J. A. (Joseph A.); Boenig, H. (Heinrich E.); Mielke, C. H. (Charles H.); Willis, J. O. (Jeffrey O.); Burley, B. L. (Burt L.)

2002-01-01T23:59:59.000Z

310

Remote sensing survey of the Coso geothermal area, Inyo county, California.  

Open Energy Info (EERE)

sensing survey of the Coso geothermal area, Inyo county, California. sensing survey of the Coso geothermal area, Inyo county, California. Technical publication 1968--1971 Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Report: Remote sensing survey of the Coso geothermal area, Inyo county, California. Technical publication 1968--1971 Details Activities (4) Areas (1) Regions (0) Abstract: The Coso geothermal area, located primarily within the test ranges of the Naval Weapons Center, China Lake, Calif., is an area of granitic rock exposure and fracture-controlled explosion breccias and perlitic domes. Fumarolic and hot springs activity are present at scattered locations. Remote sensing studies were made that included color and color IR photography, 8- to 14-micrometer IR imagery, and snowmelt patterns. Color photography and snowmelt patterns were of greatest utility in

311

Call for Papers IEEE TRANSACTIONS ON AUTOMATIC CONTROL  

E-Print Network [OSTI]

of applications, such as, environmental control, event detection and suppression, home automation facilitated and enhanced the automated, remote, and intelligent monitoring of a large variety of physical of application domains from industrial and building automation, to environmental, wildlife, and health

Goldberg, Bennett

312

Fusion Talk: A Remote Participation Tool  

SciTech Connect (OSTI)

Remote participation tools exist for video conferencing, document co-authoring and even for data sharing mainly through graphics. However, no single integrated solution existed to be used, whether in a daily informal basis among few researchers, or as a in more formal virtual gatherings with many participants wanting to share nuclear fusion data coming from heterogeneous databases.CFN is now developing FusionTalk, an open source project consisting of server and client software available to all nuclear fusion research institutes. It is a major complement to FireSignal[l] tools for local and remote experiments, which aims to fill the gap in what video-conferencing, data access and collaboration is concerned. Using FusionTalk web tools one can access and compare data already available on the web and which is often ignored or difficult to use. FusionTalk data search features allow researchers to easily access not only information on CFN's databases but also in other databases (interfaces are already being developed for MDS Plus, DAS Access and SDAS/FireSignal) in laboratories that run a FusionTalk server.

Santos, J. H.; Reis, F.; Fernandes, H.; Neto, A.; Duarte, A.; Oliveira, F. [Associacao Euratom/IST, Centro de Fusao Nuclear, Av. Rovisco Pais P-1049-001 Lisboa (Portugal); Sa, W. P. de [Instituto de Fisica, Universidade de Sao Paulo, Rua do Matao, Travessa R, 187 05508-090 Sao Paulo, SP (Brazil)

2008-04-07T23:59:59.000Z

313

Integrated environmental monitoring at remote ecosystems  

SciTech Connect (OSTI)

The first annual report reviews progress to date on the Idaho National Engineering Laboratory(INEL) research project, Integrated Ecosystem and Pollutant Monitoring at Remote Wilderness Study Sites.'' The two primary objectives of this study are to apply, field test, and conceptually evaluate the US Forest Service guidelines for remote ecosystem monitoring and to provide an ongoing database on selected high-elevation ecosystem attributes, including physical, chemical, and biological parameters. The basic criteria for evaluation of the guidelines are usability, cost-effectiveness, data variability, alternative approaches, ecosystem conceptual approach, and quality assurance. The goal of the project is to identify a list of pollutant measurements and ecological attributes that will provide good, quality-assured data about a particular ecosystem. The present report covers each of the major components of the Forest Service guidelines except for regulatory and management constraints and visibility, which are not part of this project. Therefore, progress to date is provided as separate sections of the report for each of the following components: atomspheric environment, soils, aquatic chemistry, aquatic biology, salmonid fish, and plants (including forest ecosystem). 24 refs., 66 figs., 28 tabs.

Bruns, D.A.; O'Rourke, T.P.; Staley, C.S.; White, G.J.; Wiersma, G.B. (EG and G Idaho, Inc., Idaho Falls, ID (USA). Center for Environmental Monitoring and Assessment); Baker, G.A.; Harmon, M.E.; Smith, B.G. (Oregon State Univ., Corvallis, OR (USA). Dept. of Forest Science); Clayton, J.L. (Forest Service, Boise, ID (USA). Intermountain Research Station); Greene, S.E. (Forest Service, Corvallis, OR (USA

1988-08-01T23:59:59.000Z

314

A Distributed Control Group of Mobile Robots in a Limited Area with a Vision System  

Science Journals Connector (OSTI)

Digital remote manual control systems are no less complicated than automatic control. Engineers have to overcome number of unique problems. Mechanical parts have to respond to digital signals transferred through ...

Artur Babiarz; Robert Bieda; Krzysztof Jaskot

2013-01-01T23:59:59.000Z

315

An integrated electric plant control architecture for future navy surface combatants  

E-Print Network [OSTI]

is proposed consisting of load center controllers (LCCs), remote power controllers (RPCs), and two high speed communication layers. The philosophy of the architecture is to utilize the ship-wide communications network, which is essentially an Ethernet...

Williams, Stephen Ebert

1995-01-01T23:59:59.000Z

316

GENERATION OF A 5A, 10kV HOLLOW ELECTRON BEAM BY A PIERCE GUN J.J. BARROSO, P.J. CASTRO, J.O. ROSSI, J.A.N. GONALVES, and H. PATIRE JR.  

E-Print Network [OSTI]

GENERATION OF A 5A, 10kV HOLLOW ELECTRON BEAM BY A PIERCE GUN J.J. BARROSO, P.J. CASTRO, J.O. ROSSI experienced by the electron beam propagating across the cavity. Here we describe a Pierce gun used of short-circuits. PULSE GENERATOR VIEW GUN OPERATION The gun cathode voltage is fixed at the nominal value

317

Analysis of Remote Diagnosis Architecture for a PLCBbased Automated Assembly System  

E-Print Network [OSTI]

: remote diagnosis architecture, nature of failure, skill level of the local operator and level of expertise of the remote troubleshooter. For this purpose, three hierarchical levels of remote diagnosis architectures to diagnose failures in a PLC based...

Sekar, Ramnath

2011-10-21T23:59:59.000Z

318

Eventbased Control for Wirelessly Networked Systemsy y  

E-Print Network [OSTI]

systems Transportation networksHome automationIndustrial automation Home Network M i h bi i ProcessOre Waste A typical communication architecture for industrial automation and control Remote Clients Workplaces System Servers Operator EngineeringMaintenance Control Network Process Automation Process

Johansson, Karl Henrik

319

Novel Artificial Neural Networks For Remote-Sensing Data Classification  

E-Print Network [OSTI]

Novel Artificial Neural Networks For Remote-Sensing Data Classification Xiaoli Tao* and Howard E artificial neural network architectures applied to multi-class classification problems of remote-sensing data. These approaches are 1) a spiking-neural-network model for the partitioning of data into clusters, and 2) a neuron

Michel, Howard E.

320

Dyke quality assessment by remote sensing Robert Hack  

E-Print Network [OSTI]

FC2015 RSDYK Dyke quality assessment by remote sensing Robert Hack 14-Apr-09 1FC2015-RSDYK - Hack Robert Hack #12;Pilot project: RSDYK2008 Trial to establish whether remote sensing in combination-Apr-09 2FC2015-RSDYK - Hack #12;Test sites in Reeuwijk ­ Zuid Holland (map: Routenet-Routeplan, http

Hack, Robert

Note: This page contains sample records for the topic "kv remote control" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Real-time Remote Sensing of Snowmobiles Emissions at  

E-Print Network [OSTI]

Real-time Remote Sensing of Snowmobiles Emissions at Yellowstone National Park: An Oxygenated Fuel 68509 #12;Real-time Remote Sensing of Snowmobile Emissions at Yellowstone National Park 2 Executive emissions from snowmobiles. Ratios of CO, HC and toluene to CO2 were measured and used to calculate %CO, %HC

Denver, University of

322

Property:ProjectName | Open Energy Information  

Open Energy Info (EERE)

ProjectName ProjectName Jump to: navigation, search Property Name ProjectName Property Type String Description Project name for smart grid projects Pages using the property "ProjectName" Showing 25 pages using this property. (previous 25) (next 25) 0 0.4 kV remote control (Smart Grid Project) + 0.4 kV remote control + 2 220 kV SSSC device for power flow control (Smart Grid Project) + 220 kV SSSC device for power flow control + A A complete and normalized 61850 substation (Smart Grid Project) + A complete and normalized 61850 substation + ADELE Project AACAES (Smart Grid Project) + ADELE Project AACAES + AFTER A Framework for electrical power sysTems vulnerability identification, dEfense and Restoration (Smart Grid Project) + AFTER A Framework for electrical power sysTems vulnerability identification, dEfense and Restoration +

323

Proposed amendment for Presidential Permit PP-63 and associated modifications to 500 kV international transmission line, Forbes, Minnesota to Manitoba, Canada Northern States Power Company. Final Environmental Assessment  

SciTech Connect (OSTI)

Northern States Power Company, (NSP), a Minnesota investor owned utility has applied to the Office of Fossil Energy, United States Department of Energy, to amend Presidential Permit PP-63 to allow for alterations to the 500 kV transmission line and as sedated facilities currently regulated by this permit. The alterations proposed for the 500 kV line owned by NSP are part of a long term effort sponsored by NSP to upgrade the existing NSP transmission system to allow for increased exchange of electricity with the Manitoba Hydro-Electric Board. Presidential Permit PP-63 authorized NSP to construct, connect, operate and maintain a 500 kV line at the United States/Canadian border approximately seven-and-a-half miles west of Warroad in Roseau County, Minnesota. This line connects with a 500 kV line owned and operated by the Manitoba Hydro-Electric Board (MHEB), which extends from Dorsey, Manitoba, Canada to the United States/Canadian border. NSP proposes to increase the electricity transfer capability of this transmission facility by constructing a new 80-acre substation on the existing 500 kV line in Roseau County, Minnesota, and upgrading the existing substation at Forbes, Minnesota. The proposed Roseau substation would contain two 41.5 ohm series capacitor banks. In addition, static VAR compensators are to be installed at the existing Forbes Substation. Approximately 5 acres would be added to the 30-acre Forbes site to house the additional equipment. No new lines would enter or exit the facility. NSP proposes to place the new Roseau Substation in service in May 1993 and to complete the upgrading of the Forbes Substation in March 1994. The primary, initial purpose of these modifications is to enable NSP to import 400 megawatts of electric power from MHEB during the summer months to meet peak electrical demand in the Minneapolis-St. Paul area. It is expected that this power transfer would begin in 1993.

Not Available

1992-02-01T23:59:59.000Z

324

V-220: Juniper Security Threat Response Manager Lets Remote Authenticated  

Broader source: Energy.gov (indexed) [DOE]

0: Juniper Security Threat Response Manager Lets Remote 0: Juniper Security Threat Response Manager Lets Remote Authenticated Users Execute Arbitrary Commands V-220: Juniper Security Threat Response Manager Lets Remote Authenticated Users Execute Arbitrary Commands August 17, 2013 - 4:01am Addthis PROBLEM: A remote authenticated user can execute arbitrary commands on the target system. PLATFORM: 2010.0, 2012.0, 2012.1, 2013.1 ABSTRACT: A vulnerability was reported in Juniper Security Threat Response Manager (STRM) REFERENCE LINKS: SecurityTracker Alert ID: 1028921 CVE-2013-2970 IMPACT ASSESSMENT: High DISCUSSION: A remote authenticated user can inject commands to execute arbitrary operating system commands with the privileges of the target web service. This can be exploited to gain shell access on the target device.

325

Alternative Carriers For Remote Renewable Energy Sources Using Existing Cng  

Open Energy Info (EERE)

Carriers For Remote Renewable Energy Sources Using Existing Cng Carriers For Remote Renewable Energy Sources Using Existing Cng Infrastructure Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: Alternative Carriers For Remote Renewable Energy Sources Using Existing Cng Infrastructure Details Activities (0) Areas (0) Regions (0) Abstract: Optimal locations of renewable energy sources are often remote relative to consumers and electricity grids. In contrast, some existing CNG pipelines pass through optimal renewable energy harvesting regions. The growing interest in the possibility of using geothermal energy in central Australia has created a need to assess the economic, technical, and environmental viability of converting remote renewable energy to fuel for transport using existing CNG pipelines, and to compare this alternative

326

T-526: Microsoft Internet Explorer 'ReleaseInterface()' Remote Code  

Broader source: Energy.gov (indexed) [DOE]

526: Microsoft Internet Explorer 'ReleaseInterface()' Remote Code 526: Microsoft Internet Explorer 'ReleaseInterface()' Remote Code Execution Vulnerability T-526: Microsoft Internet Explorer 'ReleaseInterface()' Remote Code Execution Vulnerability January 3, 2011 - 2:38pm Addthis PROBLEM: Microsoft Internet Explorer 'ReleaseInterface()' Remote Code Execution Vulnerability PLATFORM: Microsoft Internet Explorer 8.0.7600.16385 ABSTRACT: Microsoft Internet Explorer is prone to a remote code-execution vulnerability. Successful exploits will allow an attacker to run arbitrary code in the context of the user running the application. Failed attacks will cause denial-of-service conditions. Microsoft Internet Explorer 8.0.7600.16385 is vulnerable; other versions may also be affected. reference LINKS: SecurityFocus - Microsoft Internet Explorer

327

Remote Gas Well Monitoring Technology Applied to Marcellus Shale Site |  

Broader source: Energy.gov (indexed) [DOE]

Remote Gas Well Monitoring Technology Applied to Marcellus Shale Remote Gas Well Monitoring Technology Applied to Marcellus Shale Site Remote Gas Well Monitoring Technology Applied to Marcellus Shale Site February 10, 2012 - 12:00pm Addthis Washington, DC - A technology to remotely monitor conditions at energy-rich Marcellus Shale gas wells to help insure compliance with environmental requirements has been developed through a research partnership funded by the U.S. Department of Energy (DOE). NETL-RUA researcher Dr. Michael McCawley hasdeveloped a technology to remotely monitor theenvironment around energy-rich Marcellus Shale gas wells. Photo courtesy of West Virginia University.The technology - which involves three wireless monitoring modules to measure volatile organic compounds, dust, light and sound - is currently being tested at a Marcellus

328

T-613: Microsoft Excel Axis Properties Remote Code Execution Vulnerability  

Broader source: Energy.gov (indexed) [DOE]

613: Microsoft Excel Axis Properties Remote Code Execution 613: Microsoft Excel Axis Properties Remote Code Execution Vulnerability T-613: Microsoft Excel Axis Properties Remote Code Execution Vulnerability May 2, 2011 - 7:42am Addthis PROBLEM: Microsoft Excel is prone to a remote code-execution vulnerability because the applications fail to sufficiently validate user-supplied input. PLATFORM: Microsoft Excel (2002-2010) ABSTRACT: Microsoft Excel is prone to a remote code-execution vulnerability because the applications fails to sufficiently validate user-supplied input. Attackers can exploit this issue by enticing an unsuspecting user to open a specially crafted Excel file. Successful exploits can allow attackers to execute arbitrary code with the privileges of the user running the application. Failed exploit attempts will result in a denial-of-service

329

T-529: Apple Mac OS PackageKit Distribution Script Remote Code...  

Broader source: Energy.gov (indexed) [DOE]

29: Apple Mac OS PackageKit Distribution Script Remote Code Execution Vulnerability T-529: Apple Mac OS PackageKit Distribution Script Remote Code Execution Vulnerability January...

330

T-727:Microsoft Windows SSL/TLS Protocol Flaw Lets Remote Users...  

Office of Environmental Management (EM)

727:Microsoft Windows SSLTLS Protocol Flaw Lets Remote Users Decryption Sessions T-727:Microsoft Windows SSLTLS Protocol Flaw Lets Remote Users Decryption Sessions September 27,...

331

T-635: Cisco AnyConnect Secure Mobility Client Lets Remote Users...  

Broader source: Energy.gov (indexed) [DOE]

Client Lets Remote Users Execute Arbitrary Code and Local Users Gain Elevated Privileges T-635: Cisco AnyConnect Secure Mobility Client Lets Remote Users Execute Arbitrary Code...

332

T-673: Apple Safari Multiple Flaws Let Remote Users Execute Arbitrary...  

Broader source: Energy.gov (indexed) [DOE]

Flaws Let Remote Users Execute Arbitrary Code, Conduct Cross-Site Scripting Attacks T-673: Apple Safari Multiple Flaws Let Remote Users Execute Arbitrary Code, Conduct...

333

E-Print Network 3.0 - advanced remote technology Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Book ReviewBook Review High Performance Computing in Remote Sensing introduces the most recent advances... 10 January 2009 PHOTOGRAMMETRIC ENGINEERING & REMOTE SENSING High...

334

U-163: PHP Command Parameter Bug Lets Remote Users Obtain Potentially...  

Broader source: Energy.gov (indexed) [DOE]

63: PHP Command Parameter Bug Lets Remote Users Obtain Potentially Sensitive Information and Execute Arbitrary Code U-163: PHP Command Parameter Bug Lets Remote Users Obtain...

335

T-719:Apache mod_proxy_ajp HTTP Processing Error Lets Remote...  

Broader source: Energy.gov (indexed) [DOE]

719:Apache modproxyajp HTTP Processing Error Lets Remote Users Deny Service T-719:Apache modproxyajp HTTP Processing Error Lets Remote Users Deny Service September 16, 2011 -...

336

U-075: Apache Struts Bug Lets Remote Users Overwrite Files and...  

Broader source: Energy.gov (indexed) [DOE]

Flaw Lets Remote Users Execute Arbitrary Commands V-142: Oracle Java Reflection API Flaw Lets Remote Users Execute Arbitrary Code U-058: Apache Struts Conversion Error...

337

V-010: 3Com, HP, and H3C Switches SNMP Configuration Lets Remote...  

Broader source: Energy.gov (indexed) [DOE]

The vendor has issued a fix for some affected products. Addthis Related Articles U-240: Apple Remote Desktop Encryption Failure Lets Remote Users Obtain Potentially Sensitive...

338

V-027: Adobe InDesign Server SOAP Interface Lets Remote Users...  

Broader source: Energy.gov (indexed) [DOE]

Code U-131: Adobe Photoshop TIFF Image Heap Overflow Lets Remote Users Execute Arbitrary Code U-166: Adobe Shockwave Player Memory Corruption Flaws Let Remote Users Execute...

339

New Switches for Utility-Scale Inverters: First In-Class Demonstration of a Completely New Type of SiC Bipolar Switch (15kV-20kV) for Utility-Scale Inverters  

SciTech Connect (OSTI)

Solar ADEPT Project: The SiCLAB is developing a new power switch for utility-scale PV inverters that would improve the performance and significantly reduce the size, weight, and energy loss of PV systems. A power switch controls the electrical energy flowing through an inverter, which takes the electrical current from a PV solar panel and converts it into the type and amount of electricity that is compatible with the electric grid. SiCLAB is using silicon carbide (SiC) semiconductors in its new power switches, which are more efficient than the silicon semiconductors used to conduct electricity in most conventional power switches today. Switches with SiC semiconductors can operate at much higher temperatures, as well as higher voltage and power levels than silicon switches. SiC-based power switches are also smaller than those made with silicon alone, so they result in much smaller and lighter electrical devices. In addition to their use in utility-scale PV inverters, SiCLABs new power switches can also be used in wind turbines, railways, and other smart grid applications.

None

2011-12-31T23:59:59.000Z

340

Method to analyze remotely sensed spectral data  

DOE Patents [OSTI]

A fast and rigorous multivariate curve resolution (MCR) algorithm is applied to remotely sensed spectral data. The algorithm is applicable in the solar-reflective spectral region, comprising the visible to the shortwave infrared (ranging from approximately 0.4 to 2.5 .mu.m), midwave infrared, and thermal emission spectral region, comprising the thermal infrared (ranging from approximately 8 to 15 .mu.m). For example, employing minimal a priori knowledge, notably non-negativity constraints on the extracted endmember profiles and a constant abundance constraint for the atmospheric upwelling component, MCR can be used to successfully compensate thermal infrared hyperspectral images for atmospheric upwelling and, thereby, transmittance effects. Further, MCR can accurately estimate the relative spectral absorption coefficients and thermal contrast distribution of a gas plume component near the minimum detectable quantity.

Stork, Christopher L. (Albuquerque, NM); Van Benthem, Mark H. (Middletown, DE)

2009-02-17T23:59:59.000Z

Note: This page contains sample records for the topic "kv remote control" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Remote direct memory access over datagrams  

DOE Patents [OSTI]

A communication stack for providing remote direct memory access (RDMA) over a datagram network is disclosed. The communication stack has a user level interface configured to accept datagram related input and communicate with an RDMA enabled network interface card (NIC) via an NIC driver. The communication stack also has an RDMA protocol layer configured to supply one or more data transfer primitives for the datagram related input of the user level. The communication stack further has a direct data placement (DDP) layer configured to transfer the datagram related input from a user storage to a transport layer based on the one or more data transfer primitives by way of a lower layer protocol (LLP) over the datagram network.

Grant, Ryan Eric; Rashti, Mohammad Javad; Balaji, Pavan; Afsahi, Ahmad

2014-12-02T23:59:59.000Z

342

Waste Calcining Facility remote inspection report  

SciTech Connect (OSTI)

The purpose of the Waste Calcining Facility (WCF) remote inspections was to evaluate areas in the facility which are difficult to access due to high radiation fields. The areas inspected were the ventilation exhaust duct, waste hold cell, adsorber manifold cell, off-gas cell, calciner cell and calciner vessel. The WCF solidified acidic, high-level mixed waste generated during nuclear fuel reprocessing. Solidification was accomplished through high temperature oxidation and evaporation. Since its shutdown in 1981, the WCFs vessels, piping systems, pumps, off-gas blowers and process cells have remained contaminated. Access to the below-grade areas is limited due to contamination and high radiation fields. Each inspection technique was tested with a mock-up in a radiologically clean area before the equipment was taken to the WCF for the actual inspection. During the inspections, essential information was obtained regarding the cleanliness, structural integrity, in-leakage of ground water, indications of process leaks, indications of corrosion, radiation levels and the general condition of the cells and equipment. In general, the cells contain a great deal of dust and debris, as well as hand tools, piping and miscellaneous equipment. Although the building appears to be structurally sound, the paint is peeling to some degree in all of the cells. Cracking and spalling of the concrete walls is evident in every cell, although the east wall of the off-gas cell is the worst. The results of the completed inspections and lessons learned will be used to plan future activities for stabilization and deactivation of the facility. Remote clean-up of loose piping, hand tools, and miscellaneous debris can start immediately while information from the inspections is factored into the conceptual design for deactivating the facility.

Patterson, M.W.; Ison, W.M.

1994-08-01T23:59:59.000Z

343

Fast, accurate, and robust automatic marker detection for motion correction based on oblique kV or MV projection image pairs  

SciTech Connect (OSTI)

Purpose: A robust and accurate method that allows the automatic detection of fiducial markers in MV and kV projection image pairs is proposed. The method allows to automatically correct for inter or intrafraction motion. Methods: Intratreatment MV projection images are acquired during each of five treatment beams of prostate cancer patients with four implanted fiducial markers. The projection images are first preprocessed using a series of marker enhancing filters. 2D candidate marker locations are generated for each of the filtered projection images and 3D candidate marker locations are reconstructed by pairing candidates in subsequent projection images. The correct marker positions are retrieved in 3D by the minimization of a cost function that combines 2D image intensity and 3D geometric or shape information for the entire marker configuration simultaneously. This optimization problem is solved using dynamic programming such that the globally optimal configuration for all markers is always found. Translational interfraction and intrafraction prostate motion and the required patient repositioning is assessed from the position of the centroid of the detected markers in different MV image pairs. The method was validated on a phantom using CT as ground-truth and on clinical data sets of 16 patients using manual marker annotations as ground-truth. Results: The entire setup was confirmed to be accurate to around 1 mm by the phantom measurements. The reproducibility of the manual marker selection was less than 3.5 pixels in the MV images. In patient images, markers were correctly identified in at least 99% of the cases for anterior projection images and 96% of the cases for oblique projection images. The average marker detection accuracy was 1.4{+-}1.8 pixels in the projection images. The centroid of all four reconstructed marker positions in 3D was positioned within 2 mm of the ground-truth position in 99.73% of all cases. Detecting four markers in a pair of MV images takes a little less than a second where most time is spent on the image preprocessing. Conclusions: The authors have developed a method to automatically detect multiple markers in a pair of projection images that is robust, accurate, and sufficiently fast for clinical use. It can be used for kV, MV, or mixed image pairs and can cope with limited motion between the projection images.

Slagmolen, Pieter; Hermans, Jeroen; Maes, Frederik; Budiharto, Tom; Haustermans, Karin; Heuvel, Frank van den [Department of ESAT, Medical Image Computing, Catholic University Leuven, Leuven 3000 (Belgium) and Department of Radiology, Medical Image Computing, Catholic University Leuven, Leuven 3000 (Belgium); Department of Radiotherapy, University Hospitals Leuven, Leuven 3000 (Belgium)

2010-04-15T23:59:59.000Z

344

A system for grabbing integrated video frames remotely  

Science Journals Connector (OSTI)

A system for grabbing integrated video frames produced by a remote camera is described. As part of the pointed platform in a balloon?borne experiment we use a video charge?coupled?device camera to obtain wide field star images. To obtain images with a sufficient signal?to?noise ratio integration times of up to 1 s are required. In applications where the frame grabber and camera are physically close to each other timing the frame grabber trigger is straightforward; however there are several advantages to locating the frame grabber not on the balloon payload. As a result commands issued simultaneously to the frame grabber on the ground and the camera on the balloon can be delayed relative to each other resulting in failure to acquire an image. We have developed a system where at the end of an integration a tone is injected into the video field preceding the transmission of the integrated frame; the tone is used on the ground by a decoder circuit to control the frame grabber acquisition of the integrated frame. The system has operated successfully in the flight of a stratospheric balloon?borne telescope.

M. Halpern; S. Knotek; G. S. Tucker

1996-01-01T23:59:59.000Z

345

Argonne Chemical Sciences & Engineering - Facilities - Remote Handling  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Facilities Facilities * Actinide * Analytical Chemistry * Premium Coal Samples * Electrochemical Analysis * Glovebox * Glassblowing Fundamental Interactions Catalysis & Energy Conversion Electrochemical Energy Storage Nuclear & Environmental Processes National Security Institute for Atom-Efficient Chemical Transformations Center for Electrical Energy Storage: Tailored Interfaces Contact Us CSE Intranet Remote Handling Mockup Facility Remote Handling Mockup Facility Radiochemist Art Guelis observes technician Kevin Quigley preparing to cut open a surrogate uranium target. Argonne designed and built a Remote Handling Mockup Facility to let engineers simulate the handling of radioactive materials in a non-radioactive environment. The ability to carry out the details of an

346

Battery-operated air sampler for remote areas  

SciTech Connect (OSTI)

An air sampling system developed to evaluate air quality in biosphere reserves or in other remote areas is described. The equipment consists of a Dupont P-4000A pump and a specially designed battery pack containing Gates batteries. This air sampling system was tested in southern Utah and at 10 remote sampling sites in the Great Smoky Mountains National Park. The equipment was backpacked to the remote sampling sites, and was operated continuously at full capacity for a maximum 8-day period. Except for tampering by curious hikers at one site, the equipment operated satisfactorily.

Brown, K.W. (EPA Environmental Monitoring Systems Lab., Las Vegas, NV); Wiersma, G.B.; Frank, C.W.

1981-01-01T23:59:59.000Z

347

Preliminary Project Execution Plan for the Remote-Handled Low-Level Waste Disposal Project  

SciTech Connect (OSTI)

This preliminary project execution plan (PEP) defines U.S. Department of Energy (DOE) project objectives, roles and responsibilities of project participants, project organization, and controls to effectively manage acquisition of capital funds for construction of a proposed remote-handled low-level waste (LLW) disposal facility at the Idaho National Laboratory (INL). The plan addresses the policies, requirements, and critical decision (CD) responsibilities identified in DOE Order 413.3B, 'Program and Project Management for the Acquisition of Capital Assets.' This plan is intended to be a 'living document' that will be periodically updated as the project progresses through the CD process to construction and turnover for operation.

David Duncan

2011-05-01T23:59:59.000Z

348

Fuzzy Based Energy Management Control of A Hybrid Fuel Cell Auxiliary Power System  

E-Print Network [OSTI]

battery auxiliary power unit (APU) for remote applications where a fuel cell is the main energy source for decentralized or distributed energy production, such as telecom, remote sites or even for military applicationsFuzzy Based Energy Management Control of A Hybrid Fuel Cell Auxiliary Power System M. Godoy Simões1

Simões, Marcelo Godoy

349

Structural investigations at the Coso geothermal area using remote sensing  

Open Energy Info (EERE)

investigations at the Coso geothermal area using remote sensing investigations at the Coso geothermal area using remote sensing information, Inyo County, California Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: Structural investigations at the Coso geothermal area using remote sensing information, Inyo County, California Details Activities (1) Areas (1) Regions (0) Abstract: Remote sensing studies have been made in and adjacent to the Coso geothermal field using TM FCC satellite imagery, 1:100,000 scale, US Geological Survey orthophotos, 1:24,OOO scale, and proprietary black-and-white photography by California Energy Company, Inc., at various scales including black-and-white positive film transparencies at a scale of 1:6,000. These studies have been made in an attempt to understand the complex geology seen on the surface and to try to improve the method of

350

Geothermal Exploration In Pilgrim, Alaska- First Results From Remote  

Open Energy Info (EERE)

Pilgrim, Alaska- First Results From Remote Pilgrim, Alaska- First Results From Remote Sensing Studies Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Poster: Geothermal Exploration In Pilgrim, Alaska- First Results From Remote Sensing Studies Details Activities (3) Areas (1) Regions (0) Abstract: In an effort to develop a sustainable alternate energy resource and decrease the dependency on expensive oil in rural Alaska, the Department of Energy and the Alaska Energy Authority have jointly funded an exploration project to investigate the Pilgrim Hot Springs geothermal system in western Alaska. Phase one of the exploration involves a remote sensing based assessment of the geothermal system. We used all available cloud-free summer-time thermal infrared (TIR) images from the Landsat data archive to detect and map the surface thermal anomalies in the study area

351

Identification of a New Blind Geothermal System with Hyperspectral Remote  

Open Energy Info (EERE)

Identification of a New Blind Geothermal System with Hyperspectral Remote Identification of a New Blind Geothermal System with Hyperspectral Remote Sensing and Shallow Temperature Measurements at Columbus Salt Marsh, Esmeralda County, Nevada Jump to: navigation, search OpenEI Reference LibraryAdd to library Conference Paper: Identification of a New Blind Geothermal System with Hyperspectral Remote Sensing and Shallow Temperature Measurements at Columbus Salt Marsh, Esmeralda County, Nevada Abstract Hyperspectral remote sensing-derived mineral maps and follow-up shallow temperature measurements were used to identify a new blind geothermal target in the Columbus Salt Marsh playa, Esmeralda County, Nevada. The hyperspectral survey was conducted with the ProSpecTIR VS2 instrument and consists of 380 km2 of 4-meter spatial resolution data acquired on October

352

V-103: RSA Authentication Agent Lets Remote Users Bypass Authentication  

Broader source: Energy.gov (indexed) [DOE]

3: RSA Authentication Agent Lets Remote Users Bypass 3: RSA Authentication Agent Lets Remote Users Bypass Authentication Requirements V-103: RSA Authentication Agent Lets Remote Users Bypass Authentication Requirements March 4, 2013 - 12:27am Addthis PROBLEM: RSA Authentication Agent Lets Remote Users Bypass Authentication Requirements PLATFORM: RSA Authentication Agent 7.1, 7.1.1 for Microsoft Windows ABSTRACT: A vulnerability was reported in RSA Authentication Agent. REFERENCE LINKS: RSA SecurCare SecurityTracker Alert ID: 1028230 CVE-2013-0931 IMPACT ASSESSMENT: Medium DISCUSSION: On systems configured for Quick PIN Unlock, the system will request a PIN instead of a full Passcode when the session is activated from an active screensaver after the Quick PIN Unlock timeout has expired. RSA Authentication Agent on Windows Vista, Windows 7, Windows 2008, and

353

U-223: Bugzilla May Disclose Confidential Information to Remote Users |  

Broader source: Energy.gov (indexed) [DOE]

3: Bugzilla May Disclose Confidential Information to Remote 3: Bugzilla May Disclose Confidential Information to Remote Users U-223: Bugzilla May Disclose Confidential Information to Remote Users July 30, 2012 - 7:00am Addthis PROBLEM: Bugzilla May Disclose Confidential Information to Remote Users PLATFORM: Version(s): 2.17.5 to 3.6.9, 3.7.1 to 4.0.6, 4.1.1 to 4.2.1, 4.3.1 ABSTRACT: Two vulnerabilities were reported in Bugzilla. reference LINKS: The Vendor's Advisory Security Advisories CVE-2012-1969 CVE-2012-1968 SecurityTracker Alert ID: 1027320 Bug 777586 IMPACT ASSESSMENT: High Discussion: Bugzilla is a Web-based bug-tracking system used by a large number of software projects. The following security issues have been discovered in Bugzilla: In HTML bugmails, an improper validation of the permissions of the addressee can lead to confidential information about bugs and attachments

354

Researcher, Los Alamos National Laboratory - Space and Remote Sensing Group  

National Nuclear Security Administration (NNSA)

and Remote Sensing Group and Remote Sensing Group | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > About Us > Who We Are > In The Spotlight > Patrick Colestock Researcher, Los Alamos National Laboratory - Space and Remote Sensing Group Patrick Colestock Patrick Colestock Role: Researcher, Los Alamos National Laboratory - Space and Remote Sensing

355

T-541: Citrix Provisioning Services Unspecified Flaw Let's Remote Users  

Broader source: Energy.gov (indexed) [DOE]

41: Citrix Provisioning Services Unspecified Flaw Let's Remote 41: Citrix Provisioning Services Unspecified Flaw Let's Remote Users Execute Arbitrary Code T-541: Citrix Provisioning Services Unspecified Flaw Let's Remote Users Execute Arbitrary Code January 24, 2011 - 5:34pm Addthis PROBLEM: Citrix Provisioning Services Unspecified Flaw Let's Remote Users Execute Arbitrary Code PLATFORM: * Provisioning Services 5.1 * Provisioning Services 5.6 ABSTRACT: A vulnerability has been identified in Citrix Provisioning Services that could result in arbitrary code execution. This vulnerability can be triggered by an attacker sending a specially crafted packet to the Provisioning Services server. This vulnerability is present in all supported versions of Citrix Provisioning Services up to and including version 5.6. reference LINKS:

356

U-093: Mozilla Firefox Multiple Flaws Permit Remote Code Execution,  

Broader source: Energy.gov (indexed) [DOE]

3: Mozilla Firefox Multiple Flaws Permit Remote Code Execution, 3: Mozilla Firefox Multiple Flaws Permit Remote Code Execution, Information Disclosure, and Cross-Site Scripting Attacks U-093: Mozilla Firefox Multiple Flaws Permit Remote Code Execution, Information Disclosure, and Cross-Site Scripting Attacks February 1, 2012 - 5:51am Addthis PROBLEM: Multiple vulnerabilities were reported in Mozilla Firefox. PLATFORM: Linux (Any), UNIX (Any), Windows (Any) Version(s): prior to 3.2.26; prior to 10.0 ABSTRACT: Mozilla Firefox Multiple Flaws Permit Remote Code Execution, Information Disclosure, and Cross-Site Scripting. reference LINKS: SecurityTracker Alert ID: 1026605 CVE-2011-3659, CVE-2012-0442 CVE-2012-0443, CVE-2012-0444 CVE-2012-0445, CVE-2012-0446 CVE-2012-0447, CVE-2012-0449 CVE-2012-0450 Vendor Site IMPACT ASSESSMENT:

357

Surface modification with a remote atmospheric pressure plasma  

Science Journals Connector (OSTI)

A remote atmospheric pressure DC glow discharge is used for the treatment of polymer foils. The envisaged plasma effect is an increase in the surface ... the distribution of the current density in the plasma. The...

E. Temmerman; C. Leys

2004-03-01T23:59:59.000Z

358

Calculation and Use of Peaking Factors for Remote Terminal Emulation  

Science Journals Connector (OSTI)

An important goal of the remote terminal emulator-driven tests described here was obtaining a representative test workload. Reaching this goal depended on (i) imposing the test workload in a representative manner, (ii) using representative types of user ...

William A. Ward, Jr.; David Langan

2000-03-01T23:59:59.000Z

359

Calculation and Use of Peaking Factors for Remote Terminal Emulation  

Science Journals Connector (OSTI)

An important goal of the remote terminal emulator-driven tests described here was obtaining a representative test workload. Reaching this goal depended on (i) imposing the test workload in a representative man...

William A. Ward Jr.; David D. Langan

2000-01-01T23:59:59.000Z

360

NREL: Technology Deployment - Remote Shading Tool Has Potential...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Partners Solar Census Related Stories Solarize Contact Otto VanGeet, 303-384-7369 A solar heat map of a community from the new remote shading tool software The National Renewable...

Note: This page contains sample records for the topic "kv remote control" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Researcher, Los Alamos National Laboratory - Space and Remote Sensing Group  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

and Remote Sensing Group and Remote Sensing Group | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > About Us > Who We Are > In The Spotlight > Patrick Colestock Researcher, Los Alamos National Laboratory - Space and Remote Sensing Group Patrick Colestock Patrick Colestock Role: Researcher, Los Alamos National Laboratory - Space and Remote Sensing

362

Geobotanical Remote Sensing Applied To Targeting New Geothermal Resource  

Open Energy Info (EERE)

Geobotanical Remote Sensing Applied To Targeting New Geothermal Resource Geobotanical Remote Sensing Applied To Targeting New Geothermal Resource Locations In The Us Basin And Range With A Focus On Dixie Meadows, Nv Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: Geobotanical Remote Sensing Applied To Targeting New Geothermal Resource Locations In The Us Basin And Range With A Focus On Dixie Meadows, Nv Details Activities (1) Areas (1) Regions (0) Abstract: This paper presents an overview of the work our collaboration is doing to increase the detailed mapped resource base for geothermal exploration in the Western US. We are imaging several large areas in the western US with high resolution airborne hyperspectral and satellite multispectral sensors. We have now entered the phase where the remote sensing techniques and tools we are developing are mature enough to be

363

Hyperspectral Geobotanical Remote Sensing For Co2 Storage Monitoring | Open  

Open Energy Info (EERE)

Hyperspectral Geobotanical Remote Sensing For Co2 Storage Monitoring Hyperspectral Geobotanical Remote Sensing For Co2 Storage Monitoring Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Book: Hyperspectral Geobotanical Remote Sensing For Co2 Storage Monitoring Details Activities (1) Areas (1) Regions (0) Abstract: This project's goal is to develop remote sensing methods for early detection and spatial mapping, over whole regions simultaneously, of any surface areas under which there are significant CO2 leaks from deep underground storage formations. If large amounts of CO2 gas percolated up from a storage formation below to within plant root depth of the surface, the CO2 soil concentrations near the surface would become elevated and would affect individual plants and their local plant ecologies. Excessive soil CO2 concentrations are observed to significantly affect local plant

364

U-223: Bugzilla May Disclose Confidential Information to Remote Users |  

Broader source: Energy.gov (indexed) [DOE]

3: Bugzilla May Disclose Confidential Information to Remote 3: Bugzilla May Disclose Confidential Information to Remote Users U-223: Bugzilla May Disclose Confidential Information to Remote Users July 30, 2012 - 7:00am Addthis PROBLEM: Bugzilla May Disclose Confidential Information to Remote Users PLATFORM: Version(s): 2.17.5 to 3.6.9, 3.7.1 to 4.0.6, 4.1.1 to 4.2.1, 4.3.1 ABSTRACT: Two vulnerabilities were reported in Bugzilla. reference LINKS: The Vendor's Advisory Security Advisories CVE-2012-1969 CVE-2012-1968 SecurityTracker Alert ID: 1027320 Bug 777586 IMPACT ASSESSMENT: High Discussion: Bugzilla is a Web-based bug-tracking system used by a large number of software projects. The following security issues have been discovered in Bugzilla: In HTML bugmails, an improper validation of the permissions of the addressee can lead to confidential information about bugs and attachments

365

News Release: Advanced Network Toolkit for Assessments and Remote Mapping (ANTFARM)  

Broader source: Energy.gov (indexed) [DOE]

No-Cost ANTFARM Tool Maps Control System Networks to Help Implement No-Cost ANTFARM Tool Maps Control System Networks to Help Implement Cyber Security Standards Funded under the Department of Energy's National SCADA Test Bed Program, Sandia National Laboratories recently released a new software tool that will aid energy utility owners in mapping and visualizing their control system networks-a critical first step in meeting the North American Electric Reliability Corporation's Critical Infrastructure Protection (NERC CIP) standards. The Advanced Network Toolkit for Assessments and Remote Mapping (ANTFARM) helps utilities meet NERC CIP-005, which requires that they identify their electronic security perimeter (ESP), inside which all critical cyber assets and external access points reside. By using a utility's existing network information and

366

LNG links remote supplies and markets  

SciTech Connect (OSTI)

Liquefied natural gas (LNG) has established a niche for itself by matching remote gas supplies to markets that both lacked indigenous gas reserves and felt threatened in the aftermath of the energy crises of the 1970s and 1980s. It has provided a cost-effective energy source for these markets, while also offering an environmentally friendly fuel long before that was fashionable. The introduction of natural-gas use via LNG in the early years (mostly into France and Japan) has also allowed LNG to play a major role in developing gas infrastructure. Today, natural gas, often supplied as LNG, is particularly well-suited for use in the combined cycle technology used in independent power generation projects (IPPs). Today, LNG players cannot simply focus on monetizing gas resources. Instead, they must adapt their projects to meet the needs of changing markets. The impact of these changes on the LNG industry has been felt throughout the value chain from finding and producing gas, gas treatment, liquefaction, transport as a liquid, receiving terminals and regasification, and finally, to consumption by power producers, industrial users, and households. These factors have influenced the evolution of the LNG industry and have implications for the future of LNG, particularly in the context of worldwide natural gas.

Avidan, A.A.; Gardner, R.E.; Nelson, D.; Borrelli, E.N. [Mobil LNG Inc., Houston, TX (United States); Rethore, T.J. [Arthur D. Little Inc., Houston, TX (United States)

1997-06-02T23:59:59.000Z

367

Offshore winds using remote sensing techniques  

Science Journals Connector (OSTI)

Ground-based remote sensing instruments can observe winds at different levels in the atmosphere where the wind characteristics change with height: the range of heights where modern turbine rotors are operating. A six-month wind assessment campaign has been made with a LiDAR (Light Detection And Ranging) and a SoDAR (Sound Detection and Ranging) on the transformer/platform of the world's largest offshore wind farm located at the West coast of Denmark to evaluate their ability to observe offshore winds. The high homogeneity and low turbulence levels registered allow the comparison of LiDAR and SoDAR with measurements from cups on masts surrounding the wind farm showing good agreement for both the mean wind speed and the longitudinal component of turbulence. An extension of mean wind speed profiles from cup measurements on masts with LiDAR observations results in a good match for the free sectors at different wind speeds. The log-linear profile is fitted to the extended profiles (averaged over all stabilities and roughness lengths) and the deviations are small. Extended profiles of turbulence intensity are also shown for different wind speeds up to 161 m. Friction velocities and roughness lengths calculated from the fitted log-linear profile are compared with the Charnock model which seems to overestimate the sea roughness for the free sectors.

Alfredo Pea; Charlotte Bay Hasager; Sven-Erik Gryning; Michael Courtney; Ioannis Antoniou; Torben Mikkelsen; Paul Srensen

2007-01-01T23:59:59.000Z

368

Hybrid protocol of remote implementations of quantum operations  

E-Print Network [OSTI]

We propose a protocol of remote implementations of quantum operations by hybridizing bidirectional quantum state teleportation's (BQST) and Wang's one. The protocol is available for remote implemetations of quantum operations in the restricted sets specified in Sec. III. We also give the proof of the protocol and point out its optimization. As an extension, this hybrid protocol can be reduced to BQST and Wang protocols.

Ning Bo Zhao; An Min Wang

2007-08-04T23:59:59.000Z

369

Solid state laser media driven by remote nuclear powered fluorescence  

DOE Patents [OSTI]

An apparatus is provided for driving a solid state laser by a nuclear powered fluorescence source which is located remote from the fluorescence source. A nuclear reaction produced in a reaction chamber generates fluorescence or photons. The photons are collected from the chamber into a waveguide, such as a fiber optic waveguide. The waveguide transports the photons to the remote laser for exciting the laser.

Prelas, Mark A. (Columbia, MO)

1992-01-01T23:59:59.000Z

370

Coastal numerical modelling of tides: Sensitivity to domain size and remotely generated internal tide  

Science Journals Connector (OSTI)

The propagation of remotely generated superinertial internal tides constitutes a difficulty for the modelling of regional ocean tidal variability which we illustrate in several ways. First, the M2 tidal solution inside a control region located along the Southern California Bight coastline is monitored while the extent of the numerical domain is increased (up to 512 512 km). While the amplitude and phase of sea level averaged over the region is quasi-insensitive to domain size, a steady increase of kinetic energy, predominantly baroclinic, is observed with increasing domain size. The increasing flux of energy into the control region suggests that this trend is explained by the growing contribution from remote generation sites of internal tide which can propagate up to the control region. Increasing viscosities confirms this interpretation by lowering baroclinic energy levels and limiting their rate of increase with domain size. Doubling the grid spacing allows consideration of numerical domains 2 times larger. While the coarse grid has lower energy levels than the finer grid, the rate of energy increase with domain size appears to be slowing for the largest domain of the coarse grid simulations. Forcing the smallest domain with depth-varying tidal boundary conditions from the simulation in the largest domain produces energy levels inside the control region comparable to those in the control region for the largest domain, thereby confirming the feasibility of a nested approach. In contrast, simulations forced with a subinertial tidal constituent (K1) show that when the propagation of internal tide is limited, the control region kinetic energy is mostly barotropic and the magnitudes of variations of the kinetic energy with domain size are reduced.

Aurelien L. Ponte; Bruce D. Cornuelle

2013-01-01T23:59:59.000Z

371

2.3-MW Medium-Voltage, Three-Level Wind Energy Inverter Applying a Unique Bus Structure and 4.5-kV Si/SiC Hybrid Isolated Power Modules: Preprint  

SciTech Connect (OSTI)

A high-efficiency, 2.3-MW, medium-voltage, three-level inverter utilizing 4.5-kV Si/SiC (silicon carbide) hybrid modules for wind energy applications is discussed. The inverter addresses recent trends in siting the inverter within the base of multimegawatt turbine towers. A simplified split, three-layer laminated bus structure that maintains low parasitic inductances is introduced along with a low-voltage, high-current test method for determining these inductances. Feed-thru bushings, edge fill methods, and other design features of the laminated bus structure provide voltage isolation that is consistent with the 10.4-kV module isolation levels. Inverter efficiency improvement is a result of the (essential) elimination of the reverse recovery charge present in 4.5-kV Si PIN diodes, which can produce a significant reduction in diode turn-off losses as well as insulated-gate bipolar transistor (IGBT) turn-on losses. The hybrid modules are supplied in industry-standard 140 mm x 130 mm and 190 mm x 130 mm packages to demonstrate direct module substitution into existing inverter designs. A focus on laminated bus/capacitor-bank/module subassembly level switching performance is presented.

Erdman, W.; Keller, J.; Grider, D.; VanBrunt, E.

2014-11-01T23:59:59.000Z

372

Remote-handled transuranic waste study  

SciTech Connect (OSTI)

The Waste Isolation Pilot Plant (WIPP) was developed by the US Department of Energy (DOE) as a research and development facility to demonstrate the safe disposal of transuranic (TRU) radioactive wastes generated from the Nation`s defense activities. The WIPP disposal inventory will include up to 250,000 cubic feet of TRU wastes classified as remote handled (RH). The remaining inventory will include contact-handled (CH) TRU wastes, which characteristically have less specific activity (radioactivity per unit volume) than the RH-TRU wastes. The WIPP Land Withdrawal Act (LWA), Public Law 102-579, requires a study of the effect of RH-TRU waste on long-term performance. This RH-TRU Waste Study has been conducted to satisfy the requirements defined by the LWA and is considered by the DOE to be a prudent exercise in the compliance certification process of the WIPP repository. The objectives of this study include: conducting an evaluation of the impacts of RH-TRU wastes on the performance assessment (PA) of the repository to determine the effects of Rh-TRU waste as a part of the total WIPP disposal inventory; and conducting a comparison of CH-TRU and RH-TRU wastes to assess the differences and similarities for such issues as gas generation, flammability and explosiveness, solubility, and brine and geochemical interactions. This study was conducted using the data, models, computer codes, and information generated in support of long-term compliance programs, including the WIPP PA. The study is limited in scope to post-closure repository performance and includes an analysis of the issues associated with RH-TRU wastes subsequent to emplacement of these wastes at WIPP in consideration of the current baseline design. 41 refs.

NONE

1995-10-01T23:59:59.000Z

373

Five Kilowatt Fuel Cell Demonstration for Remote Power Applications  

SciTech Connect (OSTI)

While most areas of the US are serviced by inexpensive, dependable grid connected electrical power, many areas of Alaska are not. In these areas, electrical power is provided with Diesel Electric Generators (DEGs), at much higher cost than in grid connected areas. The reasons for the high cost of power are many, including the high relative cost of diesel fuel delivered to the villages, the high operational effort required to maintain DEGs, and the reverse benefits of scale for small utilities. Recent progress in fuel cell technologies have lead to the hope that the DEGs could be replaced with a more efficient, reliable, environmentally friendly source of power in the form of fuel cells. To this end, the University of Alaska Fairbanks has been engaged in testing early fuel cell systems since 1998. Early tests were conducted on PEM fuel cells, but since 2001, the focus has been on Solid Oxide Fuel Cells. In this work, a 5 kW fuel cell was delivered to UAF from Fuel Cell Technologies of Kingston, Ontario. The cell stack is of a tubular design, and was built by Siemens Westinghouse Fuel Cell division. This stack achieved a run of more than 1 year while delivering grid quality electricity from natural gas with virtually no degradation and at an electrical efficiency of nearly 40%. The project was ended after two control system failures resulted in system damage. While this demonstration was successful, considerable additional product development is required before this technology is able to provide electrical energy in remote Alaska. The major issue is cost, and the largest component of system cost currently is the fuel cell stack cost, although the cost of the balance of plant is not insignificant. While several manufactures are working on schemes for significant cost reduction, these systems do not as yet provide the same level of performance and reliability as the larger scale Siemens systems, or levels that would justify commercial deployment.

Dennis Witmer; Tom Johnson; Jack Schmid

2008-12-31T23:59:59.000Z

374

Remote sensing data assimilation for a prognostic phenology model  

SciTech Connect (OSTI)

Predicting the global carbon and water cycle requires a realistic representation of vegetation phenology in climate models. However most prognostic phenology models are not yet suited for global applications, and diagnostic satellite data can be uncertain and lack predictive power. We present a framework for data assimilation of Fraction of Photosynthetically Active Radiation absorbed by vegetation (FPAR) and Leaf Area Index (LAI) from the MODerate Resolution Imaging Spectroradiometer (MODIS) to constrain empirical temperature, light, moisture and structural vegetation parameters of a prognostic phenology model. We find that data assimilation better constrains structural vegetation parameters than climate control parameters. Improvements are largest for drought-deciduous ecosystems where correlation of predicted versus satellite-observed FPAR and LAI increases from negative to 0.7-0.8. Data assimilation effectively overcomes the cloud- and aerosol-related deficiencies of satellite data sets in tropical areas. Validation with a 49-year-long phenology data set reveals that the temperature-driven start of season (SOS) is light limited in warm years. The model has substantial skill (R = 0.73) to reproduce SOS inter-annual and decadal variability. Predicted SOS shows a higher inter-annual variability with a negative bias of 5-20 days compared to species-level SOS. It is however accurate to within 1-2 days compared to SOS derived from net ecosystem exchange (NEE) measurements at a FLUXNET tower. The model only has weak skill to predict end of season (EOS). Use of remote sensing data assimilation for phenology model development is encouraged but validation should be extended with phenology data sets covering mediterranean, tropical and arctic ecosystems.

Thornton, Peter E [ORNL; Stockli, Reto [Colorado State University, Fort Collins

2008-01-01T23:59:59.000Z

375

Adaptive Remote-Sensing Techniques Implementing Swarms of Mobile Agents  

SciTech Connect (OSTI)

In many situations, stand-off remote-sensing and hazard-interdiction techniques over realistic operational areas are often impractical "and difficult to characterize. An alternative approach is to implement an adap- tively deployable array of sensitive agent-specific devices. Our group has been studying the collective be- havior of an autonomous, multi-agent system applied to chedbio detection and related emerging threat applications, The current physics-based models we are using coordinate a sensor array for mukivanate sig- nal optimization and coverage as re,alized by a swarm of robots or mobile vehicles. These intelligent control systems integrate'glob"ally operating decision-making systems and locally cooperative learning neural net- works to enhance re+-timp operational responses to dynarnical environments examples of which include obstacle avoidance, res~onding to prevailing wind patterns, and overcoming other natural obscurants or in- terferences. Collectively',tkensor nefirons with simple properties, interacting according to basic community rules, can accomplish complex interconnecting functions such as generalization, error correction, pattern recognition, sensor fusion, and localization. Neural nets provide a greater degree of robusmess and fault tolerance than conventional systems in that minor variations or imperfections do not impair performance. The robotic platforms would be equipped with sensor devices that perform opticaI detection of biologicais in combination with multivariate chemical analysis tools based on genetic and neural network algorithms, laser-diode LIDAR analysis, ultra-wideband short-pulsed transmitting and receiving antennas, thermal im- a:ing sensors, and optical Communication technology providing robust data throughput pathways. Mission scenarios under consideration include ground penetrating radar (GPR) for detection of underground struc- tures, airborne systems, and plume migration and mitigation. We will describe our research in these areas anti give a status report on our progress.

Asher, R.B.; Cameron, S.M.; Loubriel, G.M.; Robinett, R.D.; Stantz, K.M.; Trahan, M.W.; Wagner, J.S.

1998-11-25T23:59:59.000Z

376

Arms control and nonproliferation technologies. Fourth quarter 1992  

SciTech Connect (OSTI)

This report includes information concerning: the Department of Energy`s Office of Arms Control and Nonproliferation; the nuclear inspections in Iraq, lessons for verification; detection technologies needed for each step of nuclear weapon development; nuclear proliferation problems; strengthening the nuclear reactor fuel cycle against proliferation; monitoring using unattended remote nondestructive assay; seismic monitoring in a proliferation environment; forensic science center, remote infrared spectrometry for nonproliferation applications; and acoustic instrument for identifying chemical munitions.

Staehle, G.; Talaber, C.; Stull, S.

1992-12-31T23:59:59.000Z

377

The bridge-type fault current controller--a new facts controller  

SciTech Connect (OSTI)

The operation of a novel current controller, which can also function as a fault current limiter and as a solid-state ac circuit breaker, is presented. The controller, which consists of a thyristor bridge, an inductor, and an optional bias power supply, is installed in series with the voltage source and the load, For load current values smaller than a preset value, the inductor of the current controller presents no impedance to the ac current flow. For values higher than the preset current value, the inductor is switched automatically into the ac circuit and limits the amount of current flow. Theoretical results in the form of circuit simulations and experimental results with a single-phase unit, operating on a 13.7 kV three-phase system with peak short-circuit currents of 3140 Arms, are presented.

Boenig, Heinrich J.; Mielke, C. H. (Charles H.); Burley, B. L. (Burt L.); Chen, Hong; Waynert, J. A. (Joseph A.); Willis, J. O. (Jeffrey O.)

2002-01-01T23:59:59.000Z

378

Securing the global, remote, mobile user  

Science Journals Connector (OSTI)

Electronic commerce is inevitable and will reshape our lives, but before true electronic commerce environments can be realized, it will be necessary to secure your enterprise against outside attacks on its electronic information and provide controls ...

Walt Curtis; Lori Sinton

1999-03-01T23:59:59.000Z

379

TARZAN: A REMOTE TOOL DEPLOYMENT SYSTEM FOR THE WEST VALLEY DEVELOPMENT PROJECT  

SciTech Connect (OSTI)

RedZone Robotics, Inc. undertook a development project to build Tarzan, a Remote Tool Delivery system to work inside nuclear waste storage tanks 8D-1 and 8D-2 at the West Valley Demonstration Project (WVDP). The removal of waste deposits from large storage tanks poses significant challenges during tank operations and closure. Limited access, the presence of chemical, radiological, and /or explosive hazards, and the need to deliver retrieval equipment to all regions of the tank exceed the capabilities of most conventional methods and equipment. Remotely operated devices for mobilizing and retrieving waste materials are needed. Some recent developments have been made in this area. However, none of these developments completely and cost-effectively address tanks that are congested with internal structures (e.g., support columns, cooling coils, fixed piping, etc.). The Tarzan system consists of the following parts: Locomotor which is deployed in the tank for inspection and cleanup; Hydraulic power unit providing system power for the locomotor and deployment unit; and Control system providing the man machine interface to control, coordinate and monitor the system. This document presents the final report on the Tarzan project.

Bruce R. Thompson; James Veri

1999-09-30T23:59:59.000Z

380

T-606: Sun Java System Access Manager Lets Remote Users Partially Modify  

Broader source: Energy.gov (indexed) [DOE]

06: Sun Java System Access Manager Lets Remote Users Partially 06: Sun Java System Access Manager Lets Remote Users Partially Modify Data and Remote Authenticated Users Partially Access Data T-606: Sun Java System Access Manager Lets Remote Users Partially Modify Data and Remote Authenticated Users Partially Access Data April 20, 2011 - 3:58am Addthis PROBLEM: Two vulnerabilities were reported in Sun Java System Access Manager. A remote authenticated user can partially access data on the target system. A remote user can partially modify data on the target system. PLATFORM: Sun Java versions 7.1, 8.0 ABSTRACT: Sun Java System Access Manager Lets Remote Users Partially Modify Data and Remote Authenticated Users Partially Access Data. reference LINKS: SecurityTracker Alert ID: 1025408 CVE-2011-0844 CVE-2011-0847 Oracle Critical Patch Update Advisory

Note: This page contains sample records for the topic "kv remote control" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Remote Engineering progress report, January-December 1984  

SciTech Connect (OSTI)

This report summarizes progress on work performed in the Remote Engineering group at Rocky Flats from January to December 1984. Remote Engineering's goals in all 1984 projects were to help increase production capacity, reduce radiation exposure, improve operation safety, improve product quality, or alleviate material-accounting errors. To convert manual operations to automated operations, Remote Engineering provided design, fabrication, and assembly of new equipment for varied plant operations. Seventeen separate projects were handled by Remote Engineering in 1984. Four of the projects automate related operations in Building 559, the Chemical Analytical Laboratory. In Building 559, the following operations needed mechanizing: Sample Cutting, Storage and Retrieval, Pneumatic Transfer System, and Chemical Operations Robotic System. Remote Engineering has completed the design of the hot-dip zinc-galvanizing furnace, and Maintenance will complete the assembly and installation. Three systems are in production use but are still undergoing development: the Unimate robot, the Laser Marker, and the Ingot Gripper. The Plutonium Oxide/Skull-Burn Furnace is awaiting installation. The other projects are at various states of design and development. These reports reflect the status of the projects as they existed December 31, 1984, except the Future Work sections which were updated August 27, 1985.

Phillips, D.E.

1985-12-23T23:59:59.000Z

382

A review of remote sensing methods for biomass feedstock production  

Science Journals Connector (OSTI)

Monitoring and maximization of bioenergy yield from biomass feedstock has recently become a critically important goal for researchers. Remote sensing represents a potential method to monitor and estimate biomass so as to increase biomass feedstock production from energy crops. This paper reviews the biophysical properties of biomass and remote sensing methods for monitoring energy crops for site-specific management. While several research studies have addressed the agronomic dimensions of this approach, more research is required on perennial energy crops in order to maximize the yield of biomass feedstock. Assessment of established methods could lead to a new strategy to monitor energy crops for the adoption of site-specific management in biomass feedstock production. In this article, satellite, aerial and ground-based remote sensings were reviewed and focused on the spatial and temporal resolutions of imagery to adopt for site-specific management. We have concluded that the biomass yield prediction, the ground-based sensing is the most suitable to establish the calibration model and reference for aerial and satellite remote sensing. The aerial and satellite remote sensing are required for wide converge of planning and policy implementations of biomass feedstock production systems.

T. Ahamed; L. Tian; Y. Zhang; K.C. Ting

2011-01-01T23:59:59.000Z

383

Multi-UAV Control with the Paparazzi System Pascal Brisset and Gautier Hattenberger  

E-Print Network [OSTI]

Multi-UAV Control with the Paparazzi System Pascal Brisset and Gautier Hattenberger ENAC, Toulouse experiments involving multi- UAV control. In the first one, three UAVs flew in formation flight, con- trolled. Controlling a UAV from a dis- tant remote place requires to share the control authority between the local

Paris-Sud XI, Université de

384

2244 IEEE TRANSACTIONS ON AUTOMATIC CONTROL, VOL. 56, NO. 10, OCTOBER 2011 Guest Editorial  

E-Print Network [OSTI]

of applications, such as, environmental control, event detection and suppression, home automation, manufacturing and forms, have greatly facilitated and enhanced the automated, remote, and intelligent monitoring penetrated a plethora of application domains from industrial and building automation, to environmental

Johansson, Karl Henrik

385

Nanomedicine: making controllable magnetic drug delivery possible for the treatment of breast cancer  

Science Journals Connector (OSTI)

A recent study published in Nano Letters documents the synthesis and performance of porous silica nanocapsules filled with magnetic nanoparticles as a controllable magnetic drug delivery vector. Under a remotely ...

Lesa A Tran; Lon J Wilson

2011-03-01T23:59:59.000Z

386

U-148: ActiveScriptRuby GRScript18.dll ActiveX Control Ruby Code...  

Broader source: Energy.gov (indexed) [DOE]

HTML is displayed. Impact: System access from remote Solution: The vendor has issued a patch. Addthis Related Articles U-081: McAfee SaaS 'myCIOScn.dll' ActiveX Control Lets...

387

Remote generation of high-energy terahertz pulses from two-color femtosecond laser filamentation in air  

SciTech Connect (OSTI)

We experimentally investigated the dynamic behavior of remote terahertz (THz) generation from two-color femtosecond laser-induced filamentation in air. A record-high THz pulse energy of 570 nJ at frequency below 5.5 THz was measured by optimizing the pump parameters at a controllable remote distance of 16 m, while super-broadband THz (<300 THz) pulse energy was up to 2.8 {mu}J. A further energy-scaling possibility was proposed. By analyzing simultaneously the fluorescence from both neutral N{sub 2} and N{sub 2}{sup +} in the filament, we found that the enhancement of THz radiation was due principally to guiding of the weak second-harmonic pulse inside the filament of the first strong fundamental pulse.

Wang, T.-J.; Daigle, J.-F.; Yuan, S.; Chin, S. L. [Centre d'Optique, Photonique et Laser (COPL) and Departement de physique, de genie physique et d'optique, Universite Laval, Quebec, Quebec G1V 0A6 (Canada); Theberge, F.; Chateauneuf, M.; Dubois, J.; Roy, G. [Defence Research and Development Canada-Valcartier, 2459 Pie-XI Boulevard North, Quebec, Quebec G3J 1X5 (Canada); Zeng, H. [State Key Laboratory of Precision Spectroscopy, East China Normal University, Shanghai 200062 (China)

2011-05-15T23:59:59.000Z

388

Hyperspectral Remote Sensing Techniques For Locating Geothermal Resources |  

Open Energy Info (EERE)

Hyperspectral Remote Sensing Techniques For Locating Geothermal Resources Hyperspectral Remote Sensing Techniques For Locating Geothermal Resources Jump to: navigation, search OpenEI Reference LibraryAdd to library Poster: Hyperspectral Remote Sensing Techniques For Locating Geothermal Resources Abstract Demonstrating the effectiveness of hyperspectral sensors to explore for geothermal resources will be critical to our nation's energy security plans. Discovering new geothermal resources will contribute to established renewable energy capacity and lower our dependence upon fuels that contribute to green house gas emissions. The use of hyperspectral data and derived imagery products is currently helping exploration managers gain greater efficiencies and drilling success. However, more work is needed as geologists continue to learn about hyperspectral imaging and, conversely,

389

T-696: RSA Adaptive Authentication Has Unspecified Remote Authenticated  

Broader source: Energy.gov (indexed) [DOE]

6: RSA Adaptive Authentication Has Unspecified Remote 6: RSA Adaptive Authentication Has Unspecified Remote Authenticated Session Re-use Flaw T-696: RSA Adaptive Authentication Has Unspecified Remote Authenticated Session Re-use Flaw August 18, 2011 - 3:09pm Addthis PROBLEM: A vulnerability was reported in RSA Adaptive Authentication. PLATFORM: 6.0.2.1 SP1 Patch 2 and SP1 Patch 3, 6.0.2.1 SP2 and SP2 Patch 1, 6.0.2.1 SP3 ABSTRACT: An issue with Adaptive Authentication (On-Premise) was discovered which in certain circumstances might affect the out-of-the-box available authentication methods. In certain circumstances, when authentication information is compromised, and with the knowledge of additional session information, the authentication information might be reused within an active session. reference LINKS: Security Tracker: 1025956

390

Geothermal Exploration Using Aviris Remote Sensing Data Over Fish Lake  

Open Energy Info (EERE)

Using Aviris Remote Sensing Data Over Fish Lake Using Aviris Remote Sensing Data Over Fish Lake Valley, Nv Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Conference Paper: Geothermal Exploration Using Aviris Remote Sensing Data Over Fish Lake Valley, Nv Details Activities (1) Areas (1) Regions (0) Abstract: Fish Lake Valley, in Esmeralda County, Nevada, sits at the southern end of the Mina Deflection where the very active Death Valley-Furnace Creek-Fish Lake Valley fault system makes a right step to transfer slip northward into the Walker Lane. Northern Fish Lake Valley has been pulling part since ca. 6 Ma, primarily along the Emigrant Peak normal fault zone (Stockli et al., 2003). Elevated tectonic activity in Fish Lake Valley suggests there may be increased fracture permeability to facilitate

391

Remote Detection of Quaternary Borate Deposits with ASTER Satellite Imagery  

Open Energy Info (EERE)

Remote Detection of Quaternary Borate Deposits with ASTER Satellite Imagery Remote Detection of Quaternary Borate Deposits with ASTER Satellite Imagery as a Geothermal Exploration Tool Jump to: navigation, search OpenEI Reference LibraryAdd to library Conference Paper: Remote Detection of Quaternary Borate Deposits with ASTER Satellite Imagery as a Geothermal Exploration Tool Abstract In the Great Basin of the western United States, geothermal fluids are sometimes associated with surface crusts of borate evaporite minerals. These borates can therefore potentially serve as a geothermal exploration tool if they can be efficiently identified and mapped in the field. We demonstrate the effectiveness of using a field-portable ASD Fieldspec® spectroradiometer, and satellite-based Advanced Spaceborne Thermal and Emitted Reflectance Radiometer (ASTER) imagery for mapping borate minerals

392

Pre-conceptual Design Assessment of DEMO Remote Maintenance  

E-Print Network [OSTI]

EDFA, as part of the Power Plant Physics and Technology programme, has been working on the pre-conceptual design of a Demonstration Power Plant (DEMO). As part of this programme, a review of the remote maintenance strategy considered maintenance solutions compatible with expected environmental conditions, whilst showing potential for meeting the plant availability targets. A key finding was that, for practical purposes, the expected radiation levels prohibit the use of complex remote handling operations to replace the first wall. In 2012/13, these remote maintenance activities were further extended, providing an insight into the requirements, constraints and challenges. In particular, the assessment of blanket and divertor maintenance, in light of the expected radiation conditions and availability, has elaborated the need for a very different approach from that of ITER. This activity has produced some very informative virtual reality simulations of the blanket segments and pipe removal that are exceptionally ...

Loving, A; Sykes, N; Iglesias, D; Coleman, M; Thomas, J; Harman, J; Fischer, U; Sanz, J; Siuko, M; Mittwollen, M; others,

2013-01-01T23:59:59.000Z

393

v9fb: a remote framebuffer infrastructure of linux  

SciTech Connect (OSTI)

v9fb is a software infrastructure that allows extending framebufFer devices in Linux over the network by providing an abstraction to them in the form of a filesystem hierarchy. Framebuffer based graphic devices export a synthetic filesystem which offers a simple and easy-to-use interface for performing common framebuffer operations. Remote framebuffer devices could be accessed over the network using the 9P protocol support in Linux. We describe the infrastructure in detail and review some of the benefits it offers similar to Plan 9 distributed systems. We discuss the applications of this infrastructure to remotely display and run interactive applications on a terminal while ofFloading the computation to remote servers, and more importantly the flexibility it offers in driving tiled-display walls by aggregating graphic devices in the network.

Kulkarni, Abhishek [Los Alamos National Laboratory; Ionkov, Latchesar [Los Alamos National Laboratory

2008-01-01T23:59:59.000Z

394

Geobotanical Remote Sensing For Geothermal Exploration | Open Energy  

Open Energy Info (EERE)

For Geothermal Exploration For Geothermal Exploration Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Book: Geobotanical Remote Sensing For Geothermal Exploration Details Activities (1) Areas (1) Regions (0) Abstract: This paper presents a plan for increasing the mapped resource base for geothermal exploration in the Western US. We plan to image large areas in the western US with recently developed high resolution hyperspectral geobotanical remote sensing tools. The proposed imaging systems have the ability to map visible faults, surface effluents, historical signatures, and discover subtle hidden faults and hidden thermal systems. Large regions can be imaged at reasonable costs. The technique of geobotanical remote sensing for geothermal signatures is based on recent successes in mapping faults and effluents the Long Valley Caldera and

395

Remote quality monitoring in the banana chain  

Science Journals Connector (OSTI)

...bypassed the warehouse handling and directly transported...chain for bananas as applied in our field tests...prioritized for port handling. Palletloads which...development and monitoring technologies have to go hand...analyser; Control in applied Physiology (CP...i) Experimental procedure for banana storage...

2014-01-01T23:59:59.000Z

396

Energy Conservation in a Manufacturing Facility Through Distributed Microprocessor Control  

E-Print Network [OSTI]

. The hierarchy consists of a central IBH Series/1 system for optimization and operator interface, a sequential logic control processor for management of a chilled water storage tank farm and remote microprocessor units located at each building for control of air...

Garcia, C. A.; Kaiser, V. A.

1981-01-01T23:59:59.000Z

397

RoboCon: A general purpose telerobotic control center  

SciTech Connect (OSTI)

This report describes human factors issues involved in the design of RoboCon, a multi-purpose control center for use in US Department of Energy remote handling applications. RoboCon is intended to be a flexible, modular control center capable of supporting a wide variety of robotic devices.

Draper, J.V.; Noakes, M.W. [Oak Ridge National Lab., TN (United States). Robotics and Process Systems Div.; Schempf, H. [Carnegie Mellon Univ., Pittsburgh, PA (United States); Blair, L.M. [Human Machine Interfaces, Inc., Knoxville, TN (United States)

1997-02-01T23:59:59.000Z

398

Techniques for remotely sensing watershed runoff potential  

E-Print Network [OSTI]

) The relation of relative permittivity to emissivity over a silty clay loam at wavelength 1. 55 cm. (After Schmugge et al. , 1974). . . . . . . . . . . . . . . Plot of 21-cm brightness temperature versus soil moisture for bare fields (after Schmugge et al... INTRODUCTION Prediction of the total volume of runoff, which might occur from a watershed during a given storm, is of primary concern in the design of flood control reservoirs. At present one of the most widely used tech- niques for estimat1ng runoff volume...

Walker, Jerry Don

2012-06-07T23:59:59.000Z

399

U-270:Trend Micro Control Manager Input Validation Flaw in Ad Hoc Query  

Broader source: Energy.gov (indexed) [DOE]

0:Trend Micro Control Manager Input Validation Flaw in Ad Hoc 0:Trend Micro Control Manager Input Validation Flaw in Ad Hoc Query Module Lets Remote Users Inject SQL Commands U-270:Trend Micro Control Manager Input Validation Flaw in Ad Hoc Query Module Lets Remote Users Inject SQL Commands September 28, 2012 - 6:00am Addthis PROBLEM: Trend Micro Control Manager Input Validation Flaw in Ad Hoc Query Module Lets Remote Users Inject SQL Commands PLATFORM: Control Manager - 3.0, 3.5, 5.0, 5.5, 6.0 ABSTRACT: Trend Micro has been notified of a potential product vulnerability in Control Manager. reference LINKS: Trend Micro Technical Support ID 1061043 SecurityTracker Alert ID: 1027584 Secunia Advisory SA50760 CVE-2012-2998 IMPACT ASSESSMENT: Medium Discussion: A vulnerability has been reported in Trend Micro Control Manager, which can

400

U-076: OpenSSL Bugs Let Remote Users Deny Service, Obtain Information, and  

Broader source: Energy.gov (indexed) [DOE]

76: OpenSSL Bugs Let Remote Users Deny Service, Obtain 76: OpenSSL Bugs Let Remote Users Deny Service, Obtain Information, and Potentially Execute Arbitrary Code U-076: OpenSSL Bugs Let Remote Users Deny Service, Obtain Information, and Potentially Execute Arbitrary Code January 6, 2012 - 8:15am Addthis PROBLEM: OpenSSL Bugs Let Remote Users Deny Service, Obtain Information, and Potentially Execute Arbitrary Code PLATFORM: OpenSSL prior to 0.9.8s; 1.x prior to 1.0.0f ABSTRACT: A remote user may be able to execute arbitrary code on the target system. reference LINKS: SecurityTracker Alert ID: 1026485 OpenSSL Security Advisory IMPACT ASSESSMENT: High Discussion: Several vulnerabilities were reported in OpenSSL. A remote user can cause denial of service conditions. A remote user can obtain sensitive information. A remote user may be able to execute arbitrary code on the

Note: This page contains sample records for the topic "kv remote control" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

U-075: Apache Struts Bug Lets Remote Users Overwrite Files and Execute  

Broader source: Energy.gov (indexed) [DOE]

075: Apache Struts Bug Lets Remote Users Overwrite Files and 075: Apache Struts Bug Lets Remote Users Overwrite Files and Execute Arbitrary Code U-075: Apache Struts Bug Lets Remote Users Overwrite Files and Execute Arbitrary Code January 5, 2012 - 8:15am Addthis PROBLEM: Apache Struts Bug Lets Remote Users Overwrite Files and Execute Arbitrary Code PLATFORM: Version(s): 2.1.0 - 2.3.1 ABSTRACT: A remote user can execute arbitrary Java code on the target system. reference LINKS: SecurityTracker Alert ID: 1026484 Secunia Advisory SA47393 Bugtraq ID: 51257 Apache Struts 2 Documentation S2-008 IMPACT ASSESSMENT: High Discussion: A vulnerability was reported in Apache Struts. A remote user can execute arbitrary Java code on the target system. A remote user can overwrite arbitrary files on the target system. A remote user can send specially

402

T-579: BlackBerry Device Software Bug in WebKit Lets Remote Users...  

Broader source: Energy.gov (indexed) [DOE]

79: BlackBerry Device Software Bug in WebKit Lets Remote Users Execute Code T-579: BlackBerry Device Software Bug in WebKit Lets Remote Users Execute Code March 15, 2011 - 5:05pm...

403

T-648: Avaya IP Office Manager TFTP Server Lets Remote Users...  

Broader source: Energy.gov (indexed) [DOE]

48: Avaya IP Office Manager TFTP Server Lets Remote Users Traverse the Directory T-648: Avaya IP Office Manager TFTP Server Lets Remote Users Traverse the Directory June 16, 2011 -...

404

T-568: Mozilla Firefox Bugs Let Remote Users Conduct Cross-Site...  

Broader source: Energy.gov (indexed) [DOE]

Let Remote Users Conduct Cross-Site Request Forgery Attacks and Execute Arbitrary Code T-568: Mozilla Firefox Bugs Let Remote Users Conduct Cross-Site Request Forgery Attacks...

405

T-692: VMware vFabric tc Server Lets Remote Users Login Using...  

Broader source: Energy.gov (indexed) [DOE]

2: VMware vFabric tc Server Lets Remote Users Login Using Obfuscated Passwords T-692: VMware vFabric tc Server Lets Remote Users Login Using Obfuscated Passwords August 12, 2011 -...

406

T-685: Cisco Warranty CD May Load Malware From a Remote Site...  

Broader source: Energy.gov (indexed) [DOE]

5: Cisco Warranty CD May Load Malware From a Remote Site T-685: Cisco Warranty CD May Load Malware From a Remote Site August 5, 2011 - 3:26pm Addthis PROBLEM: A vulnerability was...

407

Information to iteration : using information and communication technologies [ICT] in design for remote regions  

E-Print Network [OSTI]

Remote design comes with significant challenges. A major barrier to designing in remote regions is the lack of communication between designers and users. As a result, the lack of information flow leads to assumptions about ...

Griffith, Kenfield A. (Kenfield Allistair)

2012-01-01T23:59:59.000Z

408

Remote Sensing and GIS Approach for Water-Well Site Selection, Southwest Iran  

Science Journals Connector (OSTI)

...Remote Sensing and GIS, Shahid Chamran University, Ahvaz, Iran 2 Department of Geology, Shahid Chamran University, Ahvaz, Iran 3 Department of Remote Sensing and GIS, Shahid Chamran University, Ahvaz, Iran 4 Kentucky Geological...

KAZEM RANGZAN; ABASS CHARCHI; EHSAN ABSHIRINI; JAMES DINGER

409

U-201: HP System Management Homepage Bugs Let Remote Users Deny...  

Broader source: Energy.gov (indexed) [DOE]

01: HP System Management Homepage Bugs Let Remote Users Deny Service U-201: HP System Management Homepage Bugs Let Remote Users Deny Service June 28, 2012 - 7:00am Addthis PROBLEM:...

410

V-142: Oracle Java Reflection API Flaw Lets Remote Users Execute...  

Broader source: Energy.gov (indexed) [DOE]

2: Oracle Java Reflection API Flaw Lets Remote Users Execute Arbitrary Code V-142: Oracle Java Reflection API Flaw Lets Remote Users Execute Arbitrary Code April 25, 2013 - 12:14am...

411

U-279: Cisco Firewall Services Module Bugs Let Remote Users Execute...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Users Deny Service and Remote Authenticated Users Modify the Configuration and Execute Arbitrary Code V-071: Cisco ASA 1000V Cloud Firewall H.323 Inspection Bug Lets Remote Users...

412

Flood monitoring, mapping and assessing capabilities using RADARSAT remote sensing, GIS and ground data for Bangladesh  

Science Journals Connector (OSTI)

Remote sensing is the most practical method available to managers of flood-prone areas for quantifying and mapping flood impacts. This study explored large inundation ... were also used. RADARSAT remote sensing d...

Roxana Hoque; Daichi Nakayama; Hiroshi Matsuyama; Jun Matsumoto

2011-05-01T23:59:59.000Z

413

U-048: HP LaserJet Printers Unspecified Flaw Lets Remote Users...  

Broader source: Energy.gov (indexed) [DOE]

AutoStart Buffer Overflows Let Remote Users Execute Arbitrary Code U-047: Siemens Automation License Manager Bugs Let Remote Users Deny Service or Execute Arbitrary Code U-052:...

414

V-104: Oracle Java Flaw Lets Remote Users Execute Arbitrary Code...  

Broader source: Energy.gov (indexed) [DOE]

Code V-104: Oracle Java Flaw Lets Remote Users Execute Arbitrary Code March 5, 2013 - 12:53am Addthis PROBLEM: Oracle Java Flaw Lets Remote Users Execute Arbitrary Code...

415

U-239: Apple iPhone SMS Processing Flaw Lets Remote Users Spoof...  

Broader source: Energy.gov (indexed) [DOE]

39: Apple iPhone SMS Processing Flaw Lets Remote Users Spoof SMS Source Addresses U-239: Apple iPhone SMS Processing Flaw Lets Remote Users Spoof SMS Source Addresses August 20,...

416

V-015: Apple iOS Bugs Let Remote Users Execute Arbitrary Code...  

Broader source: Energy.gov (indexed) [DOE]

5: Apple iOS Bugs Let Remote Users Execute Arbitrary Code, Local Users Bypass the Screen Lock, and Applications Obtain Kernel Address Information V-015: Apple iOS Bugs Let Remote...

417

T-684: Apple QuickTime Buffer Overflows Let Remote Users Execute...  

Broader source: Energy.gov (indexed) [DOE]

84: Apple QuickTime Buffer Overflows Let Remote Users Execute Arbitrary Code T-684: Apple QuickTime Buffer Overflows Let Remote Users Execute Arbitrary Code August 4, 2011 - 3:33pm...

418

U-121: Apple iOS Bugs Let Remote Users Execute Arbitrary Code...  

Broader source: Energy.gov (indexed) [DOE]

21: Apple iOS Bugs Let Remote Users Execute Arbitrary Code, Conduct Cross-Site Scripting Attacks, and Obtain Potentially Sensitive Information U-121: Apple iOS Bugs Let Remote...

419

Deadlock during first touch of upc_alloc'd remote memory when...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Parallel C) UPC Bug Reports Deadlock during first touch of upcalloc'd remote memory when target is in upcbarrier Deadlock during first touch of upcalloc'd remote memory...

420

Advanced photovoltaic/hydro hybrid renewable energy system for remote areas  

Science Journals Connector (OSTI)

This paper presents modeling and simulation of the advanced photovoltaic (PV)/hydro based Hybrid Renewable Energy System (HRES) to electrify such isolated/remote areas where grid accessibility is not possible. For 7.5?kW hydro generation system a Self Excited Induction Generator (SEIG) with improved technique is used to optimize the utilization of hydro power. To achieve this aim an uncontrolled bridge rectifier coupled with Hydro side Voltage Source Inverter is implemented for the SEIG based advanced hydro system. The PV system is configured by PV array battery DC/DC converter maximum power point tracking controller and PV side Voltage Source Inverter. A Constant Current Control scheme is developed in this paper to control active and reactive power flow and to synchronize hydro and PV systems. The proposed system uses fewer controlled switches hence complexity of control has been reduced and system has higher efficiency and lower switching losses. The performance analysis of the HRES has been done to authenticate the existence of the system using the MATLAB software and results demonstrate that power quality of the proposed system is better and HRES is able to put into services.

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "kv remote control" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

U-153: EMC Data Protection Advisor Server and Collector Bugs Let Remote Users Deny Service  

Broader source: Energy.gov [DOE]

Two vulnerabilities were reported in EMC Data Protection Advisor. A remote user can cause denial of service conditions.

422

E-Print Network 3.0 - american remote sensing Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

land surface biogeophysical variables from optical remote sensing... : Earth system models and many other applications require biogeophysical ... Source: Liang, Shunlin -...

423

Remote Access to Brookhaven, Information Services Division (ISD),  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

ISD Homepage ISD Homepage Site Details ISD Staff Remote Access Other Information BNL Site Index Can't View PDFs? Remote Access to Brookhaven External BNL users who need internet access to the internal ISD website which includes the Research Library, Records Management, Publications and Technical Editing must have a Virtual Private Network (VPN) account to connect to the BNL Internal Campus Network. This account can be setup by the Accounts Management Office. Available Options Remote Access Policy Broad-Band Connection: must use VPN with a CryptoCard Token Anti-Virus Procedures All Windows PCs should be running one of Brookhaven's official anti-virus software packages when connecting remotely to the BNL Internal Campus Network. Anti-Virus procedures are an important component of BNL's host-based security architecture. Anti-Virus software is the component of this architecture that provides a protection mechanism against malicious code. Malicious codes are programs, such as Trojan horses or viruses, that run on a host system without the authorization of the system user. These codes typically come from e-mail attachments, or can be downloaded along with programs from the Internet, or through an infected floppy disk. Properly installed anti-virus software can minimize these vulnerabilities.

424

EN-025 Tools & Applications December 2008 Lidar Remote Sensing  

E-Print Network [OSTI]

IS LIDAR? Lidar (light detection and ranging system) is a relatively new type of active remote sensing are small-footprint, discrete return systems that record two to five returns for each emitted laser pulse fashion as an aerial photography camera. · An inertial measurement unit that records the pitch, yaw

425

14 - Oil spill remote sensing: A forensic approach  

Science Journals Connector (OSTI)

Publisher Summary Even though the design and electronics of sensors are becoming increasingly sophisticated and sensors are becoming much less expensive, the operational use of remote sensing equipment lags behind the development of the technology. The most common forms of oil spill surveillance and mapping is done with simple still or video photography, which provide little, if any, forensic data. Remote sensing from aircraft is still the most common form of oil spill tracking. Attempts to use satellite remote sensing for oil spills, although successful, are not necessarily as claimed and are generally limited to identifying features at sites of known oil spills. The laser fluorosensor is a most useful instrument to forensics because of its unique capability to positively identify oil against most backgrounds, including water, soil, weeds, ice, and snow. Radar offers the only potential for searching in large areas and carrying out remote sensing during foul weather conditions, but offers very poor positive detection characteristics and thus low forensic capability. The usefulness of the visible spectrum for oil detection is limited. It is, however, an economical way to document oil spills and provide baseline data on shorelines or relative positions.

Merv Fingas; Carl E. Brown

2007-01-01T23:59:59.000Z

426

Federated Clusters Using the Transparent Remote Execution (TREx) Environment  

E-Print Network [OSTI]

Federated Clusters Using the Transparent Remote Execution (TREx) Environment Richert Wang1 University of California, Irvine 442 Computer Science Building Irvine, CA 92697-3435 rkwang@ics.uci.edu Enrique Cauich University of California, Irvine 442 Computer Science Building Irvine, CA 92697

Scherson, Isaac D.

427

Princeton University Using Multi-Sensor Remote Sensing  

E-Print Network [OSTI]

(McCabe et al, 2003) Atmospheric Water Budget: Terrestrial (Land) Water Budget: QETP dt dSl --= )( #12/Particle Generator) VIC + LSMEM Ensemble/Particle Filter/Smoother Water (Energy) Balance Constrainer MeteorologicalPrinceton University Using Multi-Sensor Remote Sensing Observations for Regional Water Budget

Pan, Ming

428

Remote Sensing-Based Determination of Conifer Needle Flushing Phenology  

E-Print Network [OSTI]

Remote Sensing-Based Determination of Conifer Needle Flushing Phenology over Boreal the start of the growing season] is one of the critical phenological stage in particular to boreal forest in one of the critical boreal phenological stage, i.e., ``conifer needle flushing'' [CNF: defined

429

Satellite remote sensing of clouds and the atmosphere 3  

SciTech Connect (OSTI)

This volume contains the proceedings of EOS/SPIE Remote Sensing Symposium which was held September 21--23, 1998 in Barcelona, Spain. Topics of discussion include the following: cloud detection and characterization; earth radiation budget; data assimilation and retrieval methods; and aerosols, ozone, and trace gases.

Russell, J.E. [ed.] [Imperial College of Science, Technology and Medicine, London (United Kingdom)

1998-12-31T23:59:59.000Z

430

Remote Sensing of Railroad Locomotive Emissions: A Feasibility Study  

E-Print Network [OSTI]

of General Motors (EMD) or General Electric Transportation Systems (GETS). A diesel- electric locomotive, DC 20590 #12;Remote Sensing of Railroad Engine Emissions 2 INTRODUCTION Many cities in the United and at each remanufacture during the useful life of the engine. It is thought that regulation

Denver, University of

431

Remote Fiber Laser Cutting System for Dismantling Glass Melter - 13071  

SciTech Connect (OSTI)

Since 2008, the equipment for dismantling the used glass melter has been developed in High-level Liquid Waste (HLW) Vitrification Facility in the Japanese Rokkasho Reprocessing Plant (RRP). Due to the high radioactivity of the glass melter, the equipment requires a fully-remote operation in the vitrification cell. The remote fiber laser cutting system was adopted as one of the major pieces of equipment. An output power of fiber laser is typically higher than other types of laser and so can provide high-cutting performance. The fiber laser can cut thick stainless steel and Inconel, which are parts of the glass melter such as casings, electrodes and nozzles. As a result, it can make the whole of the dismantling work efficiently done for a shorter period. Various conditions of the cutting test have been evaluated in the process of developing the remote fiber cutting system. In addition, the expected remote operations of the power manipulator with the laser torch have been fully verified and optimized using 3D simulations. (authors)

Mitsui, Takashi; Miura, Noriaki [IHI Corporation, 1 Shin-Nakahara-cho, Isogo-ku, Yokohama, Kanagawa (Japan)] [IHI Corporation, 1 Shin-Nakahara-cho, Isogo-ku, Yokohama, Kanagawa (Japan); Oowaki, Katsura; Kawaguchi, Isao [IHI Inspection and Instrumentation Co., Ltd, 1 Shin-Nakahara-cho, Isogo-ku, Yokohama, Kanagawa (Japan)] [IHI Inspection and Instrumentation Co., Ltd, 1 Shin-Nakahara-cho, Isogo-ku, Yokohama, Kanagawa (Japan); Miura, Yasuhiko; Ino, Tooru [Japan Nuclear Fuel Limited, 4-108, Aza Okitsuke, Oaza Obuchi, Rokkasho-Mura, Kamikita-gun, Aomori (Japan)] [Japan Nuclear Fuel Limited, 4-108, Aza Okitsuke, Oaza Obuchi, Rokkasho-Mura, Kamikita-gun, Aomori (Japan)

2013-07-01T23:59:59.000Z

432

On-Road Remote Sensing of Automobile Emissions in the Denver Area: Year 6,  

E-Print Network [OSTI]

On-Road Remote Sensing of Automobile Emissions in the Denver Area: Year 6, January 2007 Gary A 80208 June 2007 #12;On-Road Remote Sensing of Automobile Emissions in the Denver Area: Year 6 1-Road Remote Sensing of Automobile Emissions in the Denver Area: Year 6 2 INTRODUCTION Many cities

Denver, University of

433

On-Road Remote Sensing of Automobile Emissions in the Phoenix Area: Year 2  

E-Print Network [OSTI]

On-Road Remote Sensing of Automobile Emissions in the Phoenix Area: Year 2 Sajal S. Pokharel, Gary Alpharetta, Georgia 30022 Contract No. E-23-4 #12;On-Road Remote Sensing of Automobile Emissions when the measurements were binned by model year. #12;On-Road Remote Sensing of Automobile Emissions

Denver, University of

434

On-Road Remote Sensing of Automobile Emissions in the Phoenix Area: Year 5,  

E-Print Network [OSTI]

On-Road Remote Sensing of Automobile Emissions in the Phoenix Area: Year 5, November 2004 Gary A, Suite 140 Alpharetta, Georgia 30022 Contract No. E-23-9 #12;On-Road Remote Sensing of Automobile campaigns.14 #12;On-Road Remote Sensing of Automobile Emissions in the Phoenix Area: Year 5 2 INTRODUCTION

Denver, University of

435

On-Road Remote Sensing of Automobile Emissions in the Phoenix Area: Year 3  

E-Print Network [OSTI]

On-Road Remote Sensing of Automobile Emissions in the Phoenix Area: Year 3 Sajal S. Pokharel, Gary Alpharetta, Georgia 30022 Contract No. E-23-4 #12;On-Road Remote Sensing of Automobile Emissions a slight negative dependence on #12;On-Road Remote Sensing of Automobile Emissions in the Phoenix Area

Denver, University of

436

On-Road Remote Sensing of Automobile Emissions in the Denver Area: Year 5,  

E-Print Network [OSTI]

On-Road Remote Sensing of Automobile Emissions in the Denver Area: Year 5, January 2005 Gary A, Suite 140 Alpharetta, Georgia 30022 Contract No. E-23-9 #12;On-Road Remote Sensing of Automobile campaigns.13 #12;On-Road Remote Sensing of Automobile Emissions in the Denver Area: Year 5 2 INTRODUCTION

Denver, University of

437

On-Road Remote Sensing of Automobile Emissions in the LaBrea Area: Year 2  

E-Print Network [OSTI]

On-Road Remote Sensing of Automobile Emissions in the LaBrea Area: Year 2 Mitchell J. Williams 140 Alpharetta, Georgia 30022 Contract No. E-23-4 #12;On-Road Remote Sensing of Automobile Emissions compared to the standard error of the mean measurements. #12;On-Road Remote Sensing of Automobile Emissions

Denver, University of

438

Protogrammetry and Remote sensing Semester Project. DSM to DTM generation -1 -5/29/2008  

E-Print Network [OSTI]

Protogrammetry and Remote sensing Semester Project. DSM to DTM generation - 1 - 5/29/2008 PHOTOGRAMMETRY AND REMOTE SENSING PROJECT Project Name: Reduction of DSM to DTM and Quality Assessment Department of Technology Zurich #12;Protogrammetry and Remote sensing Semester Project. DSM to DTM generation - 2 - 5

Giger, Christine

439

A Standardized, Cost-Effective, and Repeatable Remote Sensing Methodology to Quantify Forested  

E-Print Network [OSTI]

A Standardized, Cost-Effective, and Repeatable Remote Sensing Methodology to Quantify Forested A standardized remote sensing methodology was evaluated for its use in quantifying the forested resources.78% was within acceptable remote sensing standards for Landsat data and that forest cover types derived from 2002

Hung, I-Kuai

440

Polarimetric Remote Sensing in the Visible to Near Infrared James R. Shell II  

E-Print Network [OSTI]

Polarimetric Remote Sensing in the Visible to Near Infrared by James R. Shell II B.S. Physics Title of Dissertation: Polarimetric Remote Sensing in the Visible to Near Infrared I, James R. Shell II Remote Sensing in the Visible to Near Infrared by James R. Shell II Submitted to the Chester F. Carlson

Salvaggio, Carl

Note: This page contains sample records for the topic "kv remote control" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

RHIC stochastic cooling motion control  

SciTech Connect (OSTI)

Relativistic Heavy Ion Collider (RHIC) beams are subject to Intra-Beam Scattering (IBS) that causes an emittance growth in all three-phase space planes. The only way to increase integrated luminosity is to counteract IBS with cooling during RHIC stores. A stochastic cooling system for this purpose has been developed, it includes moveable pick-ups and kickers in the collider that require precise motion control mechanics, drives and controllers. Since these moving parts can limit the beam path aperture, accuracy and reliability is important. Servo, stepper, and DC motors are used to provide actuation solutions for position control. The choice of motion stage, drive motor type, and controls are based on needs defined by the variety of mechanical specifications, the unique performance requirements, and the special needs required for remote operations in an accelerator environment. In this report we will describe the remote motion control related beam line hardware, position transducers, rack electronics, and software developed for the RHIC stochastic cooling pick-ups and kickers.

Gassner, D.; DeSanto, L.; Olsen, R.H.; Fu, W.; Brennan, J.M.; Liaw, CJ; Bellavia, S.; Brodowski, J.

2011-03-28T23:59:59.000Z

442

Remote creation of a one-qubit mixed state through a short homogeneous spin-1/2 chain  

Science Journals Connector (OSTI)

We consider a method of remote mixed state creation of a one-qubit subsystem (receiver) in a spin-1/2 chain governed by the nearest-neighbor XY Hamiltonian. Owing to the evolution of the chain along with the variable local unitary transformation of the one- or two-qubit sender, a large variety of receiver states can be created during a specific time interval starting with a fixed initial state of the whole quantum system. These states form the creatable region of the receiver's state-space. It is remarkable that, with a two-qubit sender, a large creatable region may be covered at a properly fixed time instant t0 using just the variable local unitary transformation of the sender. In this case we have completely local control of remote state creation. In general, for a given initial state, there are some receiver states that may not be created using the above tool. These states form the unavailable region. In turn, this unavailable region might be the creatable region of another sender. Thus, in future, we have a way to share the whole receiver's state-space among the creatable regions of several senders. The effectiveness of remote state creation is characterized by the density function of the creatable region.

A. I. Zenchuk

2014-11-04T23:59:59.000Z

443

Los Alamos identifies internal material control issue  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Internal material control issue Internal material control issue Los Alamos identifies internal material control issue The error relates to internal inventory and accounting that documents movement of sensitive materials within a small portion of Technical Area 55. February 26, 2009 Los Alamos National Laboratory sits on top of a once-remote mesa in northern New Mexico with the Jemez mountains as a backdrop to research and innovation covering multi-disciplines from bioscience, sustainable energy sources, to plasma physics and new materials. Los Alamos National Laboratory sits on top of a once-remote mesa in northern New Mexico with the Jemez mountains as a backdrop to research and innovation covering multi-disciplines from bioscience, sustainable energy sources, to plasma physics and new materials.

444

Environmental Assessment and Finding of No Significant Impact: Western's Hoover Dam Bypass Project Phase II (Double-Circuiting a Portion of the Hoover-Mead No.5 and No.7 230-kV Transmission Lines with the Henderson-Mead No.1 230-kV Transmission Line, Clark County, Nevada)  

SciTech Connect (OSTI)

The U.S. Highway 93 (U.S. 93) Hoover Dam Bypass Project calls for the U.S. Department of Energy (DOE) Western Area Power Administration (Western) to remove its Arizona and Nevada (A&N) Switchyard. As a result of this action, Western must reconfigure its existing electrical transmission system in the Hoover Dam area. Western proposes to double-circuit a portion of the Hoover-Mead No.5 and No.7 230-kV Transmission Lines with the Henderson-Mead No.1 Transmission Line (see Figure 1-1). Double-circuiting is the placement of two separate electrical circuits, typically in the form of three separate conductors or bundles of conductors, on the same set of transmission line structures. The old Henderson-Hoover 230-kV Transmission Line would become the new Henderson-Mead No.1 and would extend approximately eight miles to connect with the Mead Substation. Western owns, operates, and maintains the Hoover-Mead No.5 and No.7, and Henderson-Hoover electrical power transmission lines. Additionally, approximately 0.25 miles of new right-of-way (ROW) would be needed for the Henderson-Mead No.1 when it transfers from double-circuiting with the Hoover-Mead No.7 to the Hoover-Mead No.5 at the Boulder City Tap. The proposed project would also involve a new transmission line ROW and structures where the Henderson-Mead No.1 will split from the Hoover-Mead No.5 and enter the northeast corner of the Mead Substation. Lastly, Western has proposed adding fiber optic overhead ground wire from the Hoover Power Plant to the Mead Substation on to the Henderson-Mead No.1, Hoover-Mead No.5 and No.7 Transmission Lines. The proposed project includes replacing existing transmission line tower structures, installing new structures, and adding new electrical conductors and fiber optic cables. As a consequence of these activities, ground disturbance may result from grading areas for structure placement, constructing new roads, improving existing roads for vehicle and equipment access, and from installing structures, conductors, and fiber optic cables. Project construction activities would be conducted within the existing 200-foot transmission line ROW and 50-foot access road ROW, although new spur access roads could occur outside of existing ROWs. As lead Federal agency for this action under National Environmental Policy Act (NEPA), Western must ensure that adverse environmental effects on Federal and non-Federal lands and resources are avoided or minimized. This Environmental Assessment (EA) is intended to be a concise public document that assesses the probable and known impacts to the environment from Western's Proposed Action and alternatives, and reaches a conclusion about the significance of the impacts. This EA was prepared in compliance with NEPA regulations published by the Council on Environmental Quality (40 CFR 1500-1508) and implementing procedures of the Department of Energy (10 CFR 1021).

N /A

2003-10-27T23:59:59.000Z

445

Remote system for subsea wells tested  

SciTech Connect (OSTI)

At its experimental submarine station in the Grondin field offshore the West African state of Gabon, Societe Nationale Elf-Aquitaine has run a series of inspection, repair, and maintenance tests on two producing wells using a robot controlled from the surface. Designed for water depths beyond the range of divers, the TIM robot has a pair of manipulator arms and a rotating telescopic crane installed on a 14 by 7.6 ft carriage. Five television cameras fitted at various spots on the robot allow surface operators to direct TIM in such tasks as (1) installing a jumper pipe between a Christmas tree and the manifold, (2) connecting a jumper electric cable and hydraulic hose, (3) locally operating a safety valve, and (4) removing a guide line. During 104 hr of seabed experience, TIM outperformed divers, particularly in jobs requiring great strength.

Vielvoye, R.

1981-05-04T23:59:59.000Z

446

LED lamp or bulb with remote phosphor and diffuser configuration with enhanced scattering properties  

DOE Patents [OSTI]

An LED lamp or bulb is disclosed that comprises a light source, a heat sink structure and an optical cavity. The optical cavity comprises a phosphor carrier having a conversions material and arranged over an opening to the cavity. The phosphor carrier comprises a thermally conductive transparent material and is thermally coupled to the heat sink structure. An LED based light source is mounted in the optical cavity remote to the phosphor carrier with light from the light source passing through the phosphor carrier. A diffuser dome is included that is mounted over the optical cavity, with light from the optical cavity passing through the diffuser dome. The properties of the diffuser, such as geometry, scattering properties of the scattering layer, surface roughness or smoothness, and spatial distribution of the scattering layer properties may be used to control various lamp properties such as color uniformity and light intensity distribution as a function of viewing angle.

Tong, Tao; Le Toquin, Ronan; Keller, Bernd; Tarsa, Eric; Youmans, Mark; Lowes, Theodore; Medendorp, Jr., Nicholas W; Van De Ven, Antony; Negley, Gerald

2014-11-11T23:59:59.000Z

447

DEVELOPMENT OF REMOTE HANFORD CONNECTOR GASKET REPLACEMENT TOOLING FOR DWPF  

SciTech Connect (OSTI)

The Defense Waste Processing Facility (DWPF) requested the Savannah River National Laboratory (SRNL) to develop tooling and equipment to remotely replace gaskets in mechanical Hanford connectors to reduce personnel radiation exposure as compared to the current hands-on method. It is also expected that radiation levels will continually increase with future waste streams. The equipment is operated in the Remote Equipment Decontamination Cell (REDC), which is equipped with compressed air, two master-slave manipulators (MSM's) and an electro-mechanical manipulator (EMM) arm for operation of the remote tools. The REDC does not provide access to electrical power, so the equipment must be manually or pneumatically operated. The MSM's have a load limit at full extension of ten pounds, which limited the weight of the installation tool. In order to remotely replace Hanford connector gaskets several operations must be performed remotely, these include: removal of the spent gasket and retaining ring (retaining ring is also called snap ring), loading the new snap ring and gasket into the installation tool and installation of the new gasket into the Hanford connector. SRNL developed and tested tools that successfully perform all of the necessary tasks. Removal of snap rings from horizontal and vertical connectors is performed by separate air actuated retaining ring removal tools and is manipulated in the cell by the MSM. In order install a new gasket, the snap ring loader is used to load a new snap ring into a groove in the gasket installation tool. A new gasket is placed on the installation tool and retained by custom springs. An MSM lifts the installation tool and presses the mounted gasket against the connector block. Once the installation tool is in position, the gasket and snap ring are installed onto the connector by pneumatic actuation. All of the tools are located on a custom work table with a pneumatic valve station that directs compressed air to the desired tool and vents the tools as needed. Extensive testing of tooling operation was performed in the DWPF manipulator repair shop. This testing allowed the operators to gain confidence before the equipment was exposed to radioactive contamination. The testing also led to multiple design improvements. On July 17 and 29, 2008 the Remote Gasket Replacement Tooling was successfully demonstrated in the REDC at the DWPF of The Savannah River Site.

Krementz, D.; Coughlin, Jeffrey

2009-05-05T23:59:59.000Z

448

U-107: Cisco NX-OS IP Packet Processing Flaw Lets Remote Users Deny Service  

Broader source: Energy.gov (indexed) [DOE]

07: Cisco NX-OS IP Packet Processing Flaw Lets Remote Users Deny 07: Cisco NX-OS IP Packet Processing Flaw Lets Remote Users Deny Service U-107: Cisco NX-OS IP Packet Processing Flaw Lets Remote Users Deny Service February 21, 2012 - 6:00am Addthis PROBLEM: A vulnerability was reported in Cisco NX-OS. A remote user can cause denial of service conditions. PLATFORM: Nexus 1000v, 5000, and 7000 Series Switches ABSTRACT: A remote user can send a specially crafted IP packet to cause the target device to reload. reference LINKS: Cisco Advisory SecurityTracker Alert ID:1026692 CVE-2012-0352 IMPACT ASSESSMENT: Medium Discussion: A vulnerability was reported in Cisco NX-OS. A remote user can cause denial of service conditions. A remote user can send a specially crafted IP packet to cause the target device to reload. The vulnerability occurs when the device attepts to obtain Layer 4 (e.g.,

449

U-112: PostgreSQL Bugs Let Remote Authenticated Users Gain Elevated  

Broader source: Energy.gov (indexed) [DOE]

2: PostgreSQL Bugs Let Remote Authenticated Users Gain Elevated 2: PostgreSQL Bugs Let Remote Authenticated Users Gain Elevated Privileges, Inject SQL Commands, and Spoof Certificates U-112: PostgreSQL Bugs Let Remote Authenticated Users Gain Elevated Privileges, Inject SQL Commands, and Spoof Certificates February 28, 2012 - 8:45am Addthis PROBLEM: A vulnerability was reported in PostgreSQL. PLATFORM: Version(s): prior to 8.3.18, 8.4.11, 9.0.7, 9.1.3 ABSTRACT: A remote authenticated user can gain elevated privileges. A remote authenticated user can inject SQL commands. A remote user can spoof connections in certain cases. reference LINKS: Vendor Advisory Security Tracker ID 1026744 CVE-2012-0866 IMPACT ASSESSMENT: Medium Discussion: For trigger functions marked SECURITY DEFINER, a remote authenticated user can execute a trigger function and gain elevated privileges CVE-2012-0866.

450

U-048: HP LaserJet Printers Unspecified Flaw Lets Remote Users Update  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

8: HP LaserJet Printers Unspecified Flaw Lets Remote Users 8: HP LaserJet Printers Unspecified Flaw Lets Remote Users Update Firmware with Arbitrary Code U-048: HP LaserJet Printers Unspecified Flaw Lets Remote Users Update Firmware with Arbitrary Code November 30, 2011 - 8:15am Addthis PROBLEM: HP LaserJet Printers Unspecified Flaw Lets Remote Users Update Firmware with Arbitrary Code . PLATFORM: HP LaserJet Printers manufactured prior to 2009 ABSTRACT A remote user can upgrade the printer's firmware with arbitrary code. reference LINKS: SecurityTracker Alert ID:1026357 HP Security for Imaging and Printing HP Clarifies on Printer Security IMPACT ASSESSMENT: Low Discussion: A vulnerability was reported in some HP LaserJet Printers. A remote user can update the firmware with arbitrary code. A remote user can send a specially crafted print job or specially crafted data to the

451

U-163: PHP Command Parameter Bug Lets Remote Users Obtain Potentially  

Broader source: Energy.gov (indexed) [DOE]

3: PHP Command Parameter Bug Lets Remote Users Obtain 3: PHP Command Parameter Bug Lets Remote Users Obtain Potentially Sensitive Information and Execute Arbitrary Code U-163: PHP Command Parameter Bug Lets Remote Users Obtain Potentially Sensitive Information and Execute Arbitrary Code May 7, 2012 - 7:00am Addthis PROBLEM: PHP Command Parameter Bug Lets Remote Users Obtain Potentially Sensitive Information and Execute Arbitrary Code PLATFORM: Prior to 5.3.12 and 5.4.2 ABSTRACT: A vulnerability was reported in PHP. A remote user can obtain potentially sensitive information. A remote user can execute arbitrary code on the target system. reference LINKS: SecurityTracker Alert ID: 1027022 CVE-2012-1823 CVE-2012-2311 IMPACT ASSESSMENT: High Discussion: A remote user can submit a specially crafted request containing a command

452

U-184: Mozilla Firefox Multiple Bugs Let Remote Users Execute Arbitrary  

Broader source: Energy.gov (indexed) [DOE]

U-184: Mozilla Firefox Multiple Bugs Let Remote Users Execute U-184: Mozilla Firefox Multiple Bugs Let Remote Users Execute Arbitrary Code U-184: Mozilla Firefox Multiple Bugs Let Remote Users Execute Arbitrary Code June 6, 2012 - 7:00am Addthis PROBLEM: Multiple vulnerabilities were reported in Mozilla Firefox. PLATFORM: Version(s): prior to 13.0 ABSTRACT: A remote user can cause arbitrary code to be executed on the target user's system. A remote user can conduct cross-site scripting attacks. A remote user can obtain potentially sensitive information. Reference Links: Security Tracker ID 1027120 CVE-2012-0441,CVE-2012-1937 Vendor URL IMPACT ASSESSMENT: High Discussion: A remote user can create specially crafted content that, when loaded by the target user, will trigger a memory corruption error and execute arbitrary code on the target system [CVE-2012-1937 , CVE-2012-1938, CVE-2012-1939 ].

453

T-708:Pidgin Bugs Let Remote Users Deny Service and Potentially Execute  

Broader source: Energy.gov (indexed) [DOE]

T-708:Pidgin Bugs Let Remote Users Deny Service and Potentially T-708:Pidgin Bugs Let Remote Users Deny Service and Potentially Execute Arbitrary Code T-708:Pidgin Bugs Let Remote Users Deny Service and Potentially Execute Arbitrary Code September 1, 2011 - 12:00pm Addthis PROBLEM: gtkutils.c in Pidgin before 2.10.0 on Windows allows user-assisted remote attackers to execute arbitrary programs via a file: URL in a message. PLATFORM: Pidgin before 2.10.0 on Windows ABSTRACT: Pidgin bugs let remote users deny service and potentially execute arbitrary code. reference LINKS: CVE-2011-3185 CVE-2011-2943 CVE-2011-3184 SecurityTracker Alert ID: 1025961 Pidgin Security Advisories IMPACT ASSESSMENT: High Discussion: Several vulnerabilities were reported in Pidgin. A remote user can cause denial of service conditions. A remote user can cause arbitrary code to be

454

U-010:HP Onboard Administrator Unspecified Flaw Lets Remote Users Gain  

Broader source: Energy.gov (indexed) [DOE]

0:HP Onboard Administrator Unspecified Flaw Lets Remote Users 0:HP Onboard Administrator Unspecified Flaw Lets Remote Users Gain Access U-010:HP Onboard Administrator Unspecified Flaw Lets Remote Users Gain Access October 13, 2011 - 8:15am Addthis PROBLEM: HP Onboard Administrator Unspecified Flaw Lets Remote Users Gain Access PLATFORM: Onboard Administrator (OA) 3.21 through 3.31 ABSTRACT: A remote user can gain access to the target system reference LINKS: HP Support document ID: c03048779 SecurityTracker Alert ID: 1026158 CVE-2011-3155 IMPACT ASSESSMENT: Medium Discussion: A potential security vulnerability has been identified with HP Onboard Administrator (OA). The vulnerability could be exploited remotely to gain unauthorized access. Impact: A remote user can gain access to the target system. Solution: Onboard Administrator (OA) v3.32 is available.

455

U-047: Siemens Automation License Manager Bugs Let Remote Users Deny  

Broader source: Energy.gov (indexed) [DOE]

7: Siemens Automation License Manager Bugs Let Remote Users 7: Siemens Automation License Manager Bugs Let Remote Users Deny Service or Execute Arbitrary Code U-047: Siemens Automation License Manager Bugs Let Remote Users Deny Service or Execute Arbitrary Code November 29, 2011 - 9:00am Addthis PROBLEM: Siemens Automation License Manager Bugs Let Remote Users Deny Service or Execute Arbitrary Code. PLATFORM: Siemens Automation License Manager 500.0.122.1 ABSTRACT: Several vulnerabilities were reported in Siemens Automation License Manager. reference LINKS: SecurityTracker Alert ID: 1026354 Bugtraq Siemens Advisory Services IMPACT ASSESSMENT: Medium Discussion: A remote user can execute arbitrary code on the target system. A remote user can cause denial of service conditions. A remote user can send specially crafted *_licensekey commands to trigger a

456

U-051: Skype Discloses IP Addresses to Remote Users | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

51: Skype Discloses IP Addresses to Remote Users 51: Skype Discloses IP Addresses to Remote Users U-051: Skype Discloses IP Addresses to Remote Users December 5, 2011 - 7:00am Addthis PROBLEM: A remote user can determine the IP address of a Skype user. PLATFORM: Skype application ABSTRACT: Skype Discloses IP Addresses to Remote Users reference LINKS: SecurityTracker Alert ID: 1026370 Forbes: Skype Flaw IMPACT ASSESSMENT: High Discussion: A remote user can initiate a Skype call to a target user to determine the target user's IP address and then terminate the call before the target user's Skype application has indicated an incoming call. The remote user does not need to be on the target user's contact list. Armed with an IP address, hackers can uncover specific information about victims, including who they chat with, what they download while online, and

457

V-006: CA ARCserve Backup Flaws Let Remote Users Execute Arbitrary Code and  

Broader source: Energy.gov (indexed) [DOE]

6: CA ARCserve Backup Flaws Let Remote Users Execute Arbitrary 6: CA ARCserve Backup Flaws Let Remote Users Execute Arbitrary Code and Deny Service V-006: CA ARCserve Backup Flaws Let Remote Users Execute Arbitrary Code and Deny Service October 19, 2012 - 6:00am Addthis PROBLEM: CA ARCserve Backup Flaws Let Remote Users Execute Arbitrary Code and Deny Service PLATFORM: CA ARCserve Backup for Windows r12.5, r15, r16 ABSTRACT: Two vulnerabilities were reported in CA ARCserve Backup. A remote user can execute arbitrary code on the target system. A remote user can cause denial of service conditions. REFERENCE LINKS: SecurityTracker Alert ID: 1027683 CA Technologies Support CVE-2012-2971 CVE-2012-2972 IMPACT ASSESSMENT: High DISCUSSION: A remote user can send specially crafted RPC requests to execute arbitrary code on the target system [CVE-2012-2971]. The code will run with the

458

V-225: McAfee Email Gateway SMTP Processing Flaw Lets Remote Users Deny  

Broader source: Energy.gov (indexed) [DOE]

5: McAfee Email Gateway SMTP Processing Flaw Lets Remote Users 5: McAfee Email Gateway SMTP Processing Flaw Lets Remote Users Deny Service V-225: McAfee Email Gateway SMTP Processing Flaw Lets Remote Users Deny Service August 23, 2013 - 1:26am Addthis PROBLEM: A vulnerability was reported in McAfee Email Gateway. A remote user can cause denial of service conditions. PLATFORM: McAfee Email Gateway (MEG) 7.5 ABSTRACT: A remote user can cause the SMTP proxy to stop responding. REFERENCE LINKS: SecurityTracker Alert ID: 1028941 GENERIC-MAP-NOMATCH IMPACT ASSESSMENT: High DISCUSSION: A vulnerability was reported in McAfee Email Gateway. A remote user can cause denial of service conditions.A remote user can send a specially crafted e-mail to cause the ws_inv-smtp process to enter an infinite loop and cause the target SMTP proxy to stop responding.

459

U-072:Apache Tomcat Hash Table Collision Bug Lets Remote Users Deny Service  

Broader source: Energy.gov (indexed) [DOE]

72:Apache Tomcat Hash Table Collision Bug Lets Remote Users Deny 72:Apache Tomcat Hash Table Collision Bug Lets Remote Users Deny Service U-072:Apache Tomcat Hash Table Collision Bug Lets Remote Users Deny Service December 30, 2011 - 9:15am Addthis PROBLEM: Apache Tomcat Hash Table Collision Bug Lets Remote Users Deny Service PLATFORM: apache Tomcat 5.5.34, 6.0.34, 7.0.22; and prior versions aBSTRACT: A remote user can cause performance to degrade on the target server. reference LINKS: Apache Tomcat Security Alert SecurityTracker Alert ID: 1026477 nruns Advisory SA-2011.004 Secunia Advisory SA47411 CVE-2011-4084 IMPACT ASSESSMENT: Medium Discussion: A vulnerability was reported in Apache Tomcat. A remote user can cause denial of service conditions. A remote user can send specially crafted POST request values to trigger hash collisions and cause significant performance

460

U-258: Adobe Flash Player Flaw Lets Remote Users Execute Arbitrary Code |  

Broader source: Energy.gov (indexed) [DOE]

8: Adobe Flash Player Flaw Lets Remote Users Execute Arbitrary 8: Adobe Flash Player Flaw Lets Remote Users Execute Arbitrary Code U-258: Adobe Flash Player Flaw Lets Remote Users Execute Arbitrary Code September 12, 2012 - 1:07pm Addthis PROBLEM: Adobe Flash Player Flaw Lets Remote Users Execute Arbitrary Code PLATFORM: 11.3.300.270 and prior (Windows, OS X); 11.2.202.236 and prior (Linux); 11.3.300.270 and prior (Chrome) ABSTRACT: A remote user can cause arbitrary code to be executed on the target user's system. Reference LINKS: CVE-2012-1535 AdobeSecurity/bulletins SecurityTracker IMPACT ASSESSMENT: High Discussion: Vulnerability was reported in Adobe Flash Player. A remote user can cause arbitrary code to be executed on the target user's system. A remote user can create a specially crafted file that, when loaded by the target user,

Note: This page contains sample records for the topic "kv remote control" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

U-041: Google Chrome Out-of-Bounds Write Error Lets Remote Users Execute  

Broader source: Energy.gov (indexed) [DOE]

1: Google Chrome Out-of-Bounds Write Error Lets Remote Users 1: Google Chrome Out-of-Bounds Write Error Lets Remote Users Execute Arbitrary Code U-041: Google Chrome Out-of-Bounds Write Error Lets Remote Users Execute Arbitrary Code November 18, 2011 - 9:00am Addthis PROBLEM: Google Chrome Out-of-Bounds Write Error Lets Remote Users Execute Arbitrary Code. PLATFORM: Version(s) prior to 15.0.874.121 ABSTRACT: A remote user can create HTML that, when loaded by the target user, will execute arbitrary code on the target user's system. reference LINKS: Stable Channel Update CVE-2011-3900 SecurityTracker Alert ID: 1026338 IMPACT ASSESSMENT: High Discussion: A vulnerability was reported in Google Chrome. A remote user can cause arbitrary code to be executed on the target user's system. A remote user can create specially crafted HTML that, when loaded by the target user,

462

V-184: Google Chrome Flash Plug-in Lets Remote Users Conduct Clickjacking  

Broader source: Energy.gov (indexed) [DOE]

4: Google Chrome Flash Plug-in Lets Remote Users Conduct 4: Google Chrome Flash Plug-in Lets Remote Users Conduct Clickjacking Attacks V-184: Google Chrome Flash Plug-in Lets Remote Users Conduct Clickjacking Attacks June 24, 2013 - 12:56am Addthis PROBLEM: Google Chrome Flash Plug-in Lets Remote Users Conduct Clickjacking Attacks PLATFORM: Google Chrome prior to 27.0.1453.116 ABSTRACT: A vulnerability was reported in Google Chrome. REFERENCE LINKS: Stable Channel Update SecurityTracker Alert ID: 1028694 CVE-2013-2866 IMPACT ASSESSMENT: Medium DISCUSSION: A remote user can create specially crafted Flash content that, when loaded by the target user, will display the Flash settings in a transparent manner, which may allow the remote user to cause the target user to modify their Flash settings. This may allow the remote user to obtain potentially

463

V-006: CA ARCserve Backup Flaws Let Remote Users Execute Arbitrary Code and  

Broader source: Energy.gov (indexed) [DOE]

6: CA ARCserve Backup Flaws Let Remote Users Execute Arbitrary 6: CA ARCserve Backup Flaws Let Remote Users Execute Arbitrary Code and Deny Service V-006: CA ARCserve Backup Flaws Let Remote Users Execute Arbitrary Code and Deny Service October 19, 2012 - 6:00am Addthis PROBLEM: CA ARCserve Backup Flaws Let Remote Users Execute Arbitrary Code and Deny Service PLATFORM: CA ARCserve Backup for Windows r12.5, r15, r16 ABSTRACT: Two vulnerabilities were reported in CA ARCserve Backup. A remote user can execute arbitrary code on the target system. A remote user can cause denial of service conditions. REFERENCE LINKS: SecurityTracker Alert ID: 1027683 CA Technologies Support CVE-2012-2971 CVE-2012-2972 IMPACT ASSESSMENT: High DISCUSSION: A remote user can send specially crafted RPC requests to execute arbitrary code on the target system [CVE-2012-2971]. The code will run with the

464

U-231: Cisco ASA SIP and WebVPN Bugs Let Remote Users Deny Service |  

Broader source: Energy.gov (indexed) [DOE]

31: Cisco ASA SIP and WebVPN Bugs Let Remote Users Deny Service 31: Cisco ASA SIP and WebVPN Bugs Let Remote Users Deny Service U-231: Cisco ASA SIP and WebVPN Bugs Let Remote Users Deny Service August 9, 2012 - 7:00am Addthis PROBLEM: Cisco ASA SIP and WebVPN Bugs Let Remote Users Deny Service PLATFORM: Version(s): ASA 5500 Series; 8.2 - 8.4 ABSTRACT: Two vulnerabilities were reported in Cisco ASA. A remote or remote authenticated user can cause denial of service conditions. reference LINKS: Release Notes for the Cisco ASA 5500 Series, 8.4(x) SecurityTracker Alert ID: 1027355 CVE-2012-2472 CVE-2012-2474 IMPACT ASSESSMENT: Medium Discussion: Two vulnerabilities were reported in Cisco ASA. 1. On systems with SIP inspection enabled, a remote user can send specially crafted SIP traffic to cause the target device to create many identical

465

U-080: Linux Kernel XFS Heap Overflow May Let Remote Users Execute  

Broader source: Energy.gov (indexed) [DOE]

80: Linux Kernel XFS Heap Overflow May Let Remote Users Execute 80: Linux Kernel XFS Heap Overflow May Let Remote Users Execute Arbitrary Code U-080: Linux Kernel XFS Heap Overflow May Let Remote Users Execute Arbitrary Code January 12, 2012 - 9:00am Addthis PROBLEM: Linux Kernel XFS Heap Overflow May Let Remote Users Execute Arbitrary Code PLATFORM: Linux ABSTRACT: A vulnerability was reported in the Linux Kernel. A remote user can cause arbitrary code to be executed on the target user's system. reference LINKS: Linux Kernel Update SecurityTracker Alert ID: 1026512 CVE-2012-0038 Red Hat Bugzilla Bug 773280 IMPACT ASSESSMENT: Medium Discussion: A remote user can create a filesystem that, when mounted by the target user, will execute arbitrary code on the target user's system. Impact: A remote user can create a specially crafted filesystem that, when mounted

466

U-055: Adobe Flash Player Bugs Let Remote Users Execute Arbitrary Code |  

Broader source: Energy.gov (indexed) [DOE]

5: Adobe Flash Player Bugs Let Remote Users Execute Arbitrary 5: Adobe Flash Player Bugs Let Remote Users Execute Arbitrary Code U-055: Adobe Flash Player Bugs Let Remote Users Execute Arbitrary Code December 8, 2011 - 8:30am Addthis PROBLEM: Adobe Flash Player Bugs Let Remote Users Execute Arbitrary Code . PLATFORM: Adobe Flash Player 11.1.102.55 on Windows and Mac OS X and prior versions ABSTRACT: Two vulnerabilities exploited by the Intevydis vd_adobe_fp module in VulnDisco Step Ahead were reported in Adobe Flash Player. reference LINKS: Secunia Advisory: SA47161 SecurityTracker Alert ID: 1026392 CVE-2011-4693 CVE-2011-4694 IMPACT ASSESSMENT: High Discussion: A remote or local user can obtain potentially sensitive information. A remote user can cause arbitrary code to be executed on the target user's system. A remote user can create a specially crafted SWF file that, when

467

U-071:HP Database Archiving Software Bugs Let Remote Users Execute  

Broader source: Energy.gov (indexed) [DOE]

1:HP Database Archiving Software Bugs Let Remote Users Execute 1:HP Database Archiving Software Bugs Let Remote Users Execute Arbitrary Code U-071:HP Database Archiving Software Bugs Let Remote Users Execute Arbitrary Code December 29, 2011 - 8:15am Addthis PROBLEM: HP Database Archiving Software Bugs Let Remote Users Execute Arbitrary Code PLATFORM: HP Database Archiving Software v6.31 ABSTRACT: A remote user can execute arbitrary code on the target system. reference LINKS: HP Database Document ID: c03128302 SecurityTracker Alert ID: 1026467 CVE-2011-4163 CVE-2011-4164 CVE-2011-4165 IMPACT ASSESSMENT: High Discussion: Several vulnerabilities were reported in HP Database Archiving Software. A remote user can execute arbitrary code on the target system. Impact: A remote user can execute arbitrary code on the target system. Solution:

468

U-118: Adobe Flash Player Bugs Let Remote Users Execute Arbitrary Code and  

Broader source: Energy.gov (indexed) [DOE]

18: Adobe Flash Player Bugs Let Remote Users Execute Arbitrary 18: Adobe Flash Player Bugs Let Remote Users Execute Arbitrary Code and Obtain Information U-118: Adobe Flash Player Bugs Let Remote Users Execute Arbitrary Code and Obtain Information March 6, 2012 - 7:00am Addthis PROBLEM: Adobe Flash Player Bugs Let Remote Users Execute Arbitrary Code and Obtain Information PLATFORM: Adobe Flash Player 10.x, Adobe Flash Player 11.x ABSTRACT: Two vulnerabilities were reported in Adobe Flash Player. A remote user can cause arbitrary code to be executed on the target user's system. A remote user can obtain potentially information. reference LINKS: Secunia Advisory SA48281 CVE-2012-0769 IMPACT ASSESSMENT: High Discussion: A remote user can create specially crafted content that, when loaded by the target user, will trigger a memory corruption error in Matrix3D and execute

469

Remote information service access system based on a client-server-service model  

DOE Patents [OSTI]

A local host computing system, a remote host computing system as connected by a network, and service functionalities: a human interface service functionality, a starter service functionality, and a desired utility service functionality, and a Client-Server-Service (CSS) model is imposed on each service functionality. In one embodiment, this results in nine logical components and three physical components (a local host, a remote host, and an intervening network), where two of the logical components are integrated into one Remote Object Client component, and that Remote Object Client component and the other seven logical components are deployed among the local host and remote host in a manner which eases compatibility and upgrade problems, and provides an illusion to a user that a desired utility service supported on a remote host resides locally on the user's local host, thereby providing ease of use and minimal software maintenance for users of that remote service.

Konrad, Allan M. (P.O. Box 4023, Berkeley, CA 94704)

1999-01-01T23:59:59.000Z

470

Remote information service access system based on a client-server-service model  

DOE Patents [OSTI]

A local host computing system, a remote host computing system as connected by a network, and service functionalities: a human interface service functionality, a starter service functionality, and a desired utility service functionality, and a Client-Server-Service (CSS) model is imposed on each service functionality. In one embodiment, this results in nine logical components and three physical components (a local host, a remote host, and an intervening network), where two of the logical components are integrated into one Remote Object Client component, and that Remote Object Client component and the other seven logical components are deployed among the local host and remote host in a manner which eases compatibility and upgrade problems, and provides an illusion to a user that a desired utility service supported on a remote host resides locally on the user's local host, thereby providing ease of use and minimal software maintenance for users of that remote service.

Konrad, Allan M. (P.O. Box 4023, Berkeley, CA 94704)

1997-01-01T23:59:59.000Z

471

U-005: Apache mod_proxy Pattern Matching Bug Lets Remote Users Access  

Broader source: Energy.gov (indexed) [DOE]

5: Apache mod_proxy Pattern Matching Bug Lets Remote Users 5: Apache mod_proxy Pattern Matching Bug Lets Remote Users Access Internal Servers U-005: Apache mod_proxy Pattern Matching Bug Lets Remote Users Access Internal Servers October 6, 2011 - 9:30am Addthis PROBLEM: Apache mod_proxy Pattern Matching Bug Lets Remote Users Access Internal Servers. PLATFORM: Apache HTTP Server 1.3.x, 2.2.21 and prior versions ABSTRACT: A remote user can access internal servers. reference LINKS: The Apache HTTP Server Project SecurityTracker Alert ID: 1026144 CVE-2011-3368 IMPACT ASSESSMENT: High Discussion: A vulnerability was reported in Apache mod_proxy. A remote user can access internal servers. When this system is configured in reverse proxy mode and uses the RewriteRule or ProxyPassMatch directives with a pattern match, a remote user can send a specially crafted request to access internal

472

U-071:HP Database Archiving Software Bugs Let Remote Users Execute  

Broader source: Energy.gov (indexed) [DOE]

1:HP Database Archiving Software Bugs Let Remote Users Execute 1:HP Database Archiving Software Bugs Let Remote Users Execute Arbitrary Code U-071:HP Database Archiving Software Bugs Let Remote Users Execute Arbitrary Code December 29, 2011 - 8:15am Addthis PROBLEM: HP Database Archiving Software Bugs Let Remote Users Execute Arbitrary Code PLATFORM: HP Database Archiving Software v6.31 ABSTRACT: A remote user can execute arbitrary code on the target system. reference LINKS: HP Database Document ID: c03128302 SecurityTracker Alert ID: 1026467 CVE-2011-4163 CVE-2011-4164 CVE-2011-4165 IMPACT ASSESSMENT: High Discussion: Several vulnerabilities were reported in HP Database Archiving Software. A remote user can execute arbitrary code on the target system. Impact: A remote user can execute arbitrary code on the target system. Solution:

473

Multi-UAV network control through dynamic task allocation: Ensuring data-rate and bit-error-rate support  

E-Print Network [OSTI]

A multi-UAV system relies on communications to operate. Failure to communicate remotely sensed mission data to the base may render the system ineffective, and the inability to exchange command and control messages can lead ...

Kopeikin, Andrew

474

Mechanisms of Remote Tropical Surface Warming during El Nio JOHN C. H. CHIANG AND BENJAMIN R. LINTNER  

E-Print Network [OSTI]

temperature) for the remote tropical surface warming. Over the remote oceans, latent heat flux acting throughMechanisms of Remote Tropical Surface Warming during El Niño JOHN C. H. CHIANG AND BENJAMIN R.10) simulations of the 1997/98 El Niño that the observed "remote" (i.e., outside the Pacific) tropical land

Lintner, Benjamin Richard

475

Surface based remote sensing of aerosol-cloud interactions  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Surface based remote sensing of aerosol-cloud interactions Surface based remote sensing of aerosol-cloud interactions Feingold, Graham NOAA/Environmental Technology Laboratory Frisch, Shelby NOAA/Environmental Technology Laboratory Min, Qilong State University of New York at Albany Category: Cloud Properties We will present an analysis of the effect of aerosol on clouds at the Southern Great Plains ARM site. New methods for retrieving cloud droplet effective radius with radar (MMCR), multifilter rotating shadowband radiometer (MFRSR), and microwave radiometer (MWR) will be discussed. Relationships based on adiabatic clouds will be used to constrain retrievals. We will investigate the use of a range of proxies for cloud condensation nuclei, ranging from surface measurements of light scattering and accumulation mode number concentration, to lidar-measured extinction or

476

Remote Sensing For Geothermal Exploration Over Buffalo Valley, Nv | Open  

Open Energy Info (EERE)

Sensing For Geothermal Exploration Over Buffalo Valley, Nv Sensing For Geothermal Exploration Over Buffalo Valley, Nv Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: Remote Sensing For Geothermal Exploration Over Buffalo Valley, Nv Details Activities (1) Areas (1) Regions (0) Abstract: Remote sensing is a useful tool for identifying the surface expression of geothermal systems based on characteristic mineral assemblages that result from hydrothermal alteration (Kratt et al., 2004; Vaughan et al., 2005). Buffalo Valley in Pershing and Lander Counties, Nevada, is an area of high potential for geothermal energy production (Shevenell et al., 2004). Geothermal heat is expressed by several hot springs with surface temperatures of up to 79°C (Olmsted et al., 1975). The hot springs and a chain of Quaternary cinder cones appear to be

477

Remote Detection Of Quaternary Borate Deposits With Aster Satellite Imagery  

Open Energy Info (EERE)

Of Quaternary Borate Deposits With Aster Satellite Imagery Of Quaternary Borate Deposits With Aster Satellite Imagery As A Geothermal Exploration Tool Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Conference Paper: Remote Detection Of Quaternary Borate Deposits With Aster Satellite Imagery As A Geothermal Exploration Tool Details Activities (2) Areas (2) Regions (0) Abstract: Unavailable Author(s): C. Kratt, M. Coolbaugh, Wendy Calvin Published: GRC, 2006 Document Number: Unavailable DOI: Unavailable Multispectral Imaging At Rhodes Marsh Area (Kratt, Et Al., 2006) Multispectral Imaging At Teels Marsh Area (Kratt, Et Al., 2006) Rhodes Marsh Geothermal Area Teels Marsh Geothermal Area Retrieved from "http://en.openei.org/w/index.php?title=Remote_Detection_Of_Quaternary_Borate_Deposits_With_Aster_Satellite_Imagery_As_A_Geothermal_Exploration_Tool&oldid=389959

478

DOE Seeks Independent Evaluation of Remote-Handled Waste Program  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Seeks Independent Evaluation Seeks Independent Evaluation Of Remote-Handled Waste Program CARLSBAD, N.M., July 24, 2001 - An independent panel of scientific and engineering experts will convene July 30 in Carlsbad to evaluate U.S. Department of Energy (DOE) plans for managing remote-handled (RH) transuranic (TRU) waste at the Waste Isolation Pilot Plant (WIPP). DOE's Carlsbad Field Office has asked the American Society of Mechanical Engineers and the Institute for Regulatory Science to review its proposed RH-TRU waste program. The program must be approved by the New Mexico Environment Department and the U.S. Environmental Protection Agency before DOE will be permitted to accept and dispose of RH-TRU waste at WIPP. "Safety and compliance are our primary considerations in developing the plans for

479

A facility to remotely assemble radioisotope thermoelectric generators  

SciTech Connect (OSTI)

Radioisotope Thermoelectric Generators (RTGs) are electrical power sources that use heat from decaying radioisotopes to directly generate electrical power. The RTG assembly process is performed in an inert atmosphere inside a large glovebox, which is surrounded by radiation shielding to reduce exposure to neutron and gamma radiation from the radioisotope heat source. In the past, allowable dose rate limits have allowed direct, manual assembly methods; however, current dose rate limits require a thicker radiation shielding that makes direct, manual assembly infeasible. To minimize RTG assembly process modifications, telerobotic systems are being investigated to perform remote assembly tasks. Telerobotic systems duplicate human arm motion and incorporate force feedback sensitivity to handle objects and tools in a human-like manner. A telerobotic system with two arms and a three-dimensional (3-D) vision system can be used to perform remote RTG assembly tasks inside gloveboxes and cells using unmodified, normal hand tools.

Engstrom, J.W.; Goldmann, L.H.; Truitt, R.W.

1992-07-01T23:59:59.000Z

480

Genetic programming approach to extracting features from remotely sensed imagery  

SciTech Connect (OSTI)

Multi-instrument data sets present an interesting challenge to feature extraction algorithm developers. Beyond the immediate problems of spatial co-registration, the remote sensing scientist must explore a complex algorithm space in which both spatial and spectral signatures may be required to identify a feature of interest. We describe a genetic programming/supervised classifier software system, called Genie, which evolves and combines spatio-spectral image processing tools for remotely sensed imagery. We describe our representation of candidate image processing pipelines, and discuss our set of primitive image operators. Our primary application has been in the field of geospatial feature extraction, including wildfire scars and general land-cover classes, using publicly available multi-spectral imagery (MSI) and hyper-spectral imagery (HSI). Here, we demonstrate our system on Landsat 7 Enhanced Thematic Mapper (ETM+) MSI. We exhibit an evolved pipeline, and discuss its operation and performance.

Theiler, J. P. (James P.); Perkins, S. J. (Simon J.); Harvey, N. R. (Neal R.); Szymanski, J. J. (John J.); Brumby, Steven P.

2001-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "kv remote control" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Remote maintenance for a new generation of hot cells  

SciTech Connect (OSTI)

For several years the Consolidated Fuel Reprocessing Program (CFRP) at Oak Ridge National Laboratory (ORNL) has been developing facility concepts, designing specialized equipment, and testing prototypical hardware for reprocessing spent fuel from fast breeder reactors. The major facility conceptual design, the Hot Experimental Facility, was based on total remote maintenance to increase plant availability and to reduce radiation exposure. This thrust included designing modular equipment to facilitate maintenance and the manipulation necessary to accomplish maintenance. Included in the design repetoire was the development effort in advanced servomanipulator systems, a remote sampling system, television viewing, and a transporter for manipulator positioning. Demonstration of these developed items is currently ongoing, and the technology is available for applications where production operations in highly radioactive environments are required.

Feldman, M.J.; Grant, N.R.

1987-01-01T23:59:59.000Z

482

Methods and systems for remote detection of gases  

DOE Patents [OSTI]

Novel systems and methods for remotely detecting at least one constituent of a gas via infrared detection are provided. A system includes at least one extended source of broadband infrared radiation and a spectrally sensitive receiver positioned remotely from the source. The source and the receiver are oriented such that a surface of the source is in the field of view of the receiver. The source includes a heating component thermally coupled to the surface, and the heating component is configured to heat the surface to a temperature above ambient temperature. The receiver is operable to collect spectral infrared absorption data representative of a gas present between the source and the receiver. The invention advantageously overcomes significant difficulties associated with active infrared detection techniques known in the art, and provides an infrared detection technique with a much greater sensitivity than passive infrared detection techniques known in the art.

Johnson, Timothy J. (Pasco, WA)

2007-11-27T23:59:59.000Z

483

Methods and systems for remote detection of gases  

DOE Patents [OSTI]

Novel systems and methods for remotely detecting at least one constituent of a gas via infrared detection are provided. A system includes at least one extended source of broadband infrared radiation and a spectrally sensitive receiver positioned remotely from the source. The source and the receiver are oriented such that a surface of the source is in the field of view of the receiver. The source includes a heating component thermally coupled to the surface, and the heating component is configured to heat the surface to a temperature above ambient temperature. The receiver is operable to collect spectral infrared absorption data representative of a gas present between the source and the receiver. The invention advantageously overcomes significant difficulties associated with active infrared detection techniques known in the art, and provides an infrared detection technique with a much greater sensitivity than passive infrared detection techniques known in the art.

Johnson, Timothy J

2012-09-18T23:59:59.000Z

484

Remote sensing of soil radionuclide fluxes in a tropical ecosystem  

SciTech Connect (OSTI)

We are using a transponding geostationary satellite to collect surface environmental data to describe the fate of soil-borne radionuclides. The remote, former atomic testing grounds at the Eniwetok and Bikini Atolls present a difficult environment in which to collect continuous field data. Our land-based, solar-powered microprocessor and environmental data systems remotely acquire measurements of net and total solar radiation, rain, humidity, temperature, and soil-water potentials. For the past year, our water flux model predicts wet season plant transpiration rates nearly equal to the 6 to 7 mm/d evaporation pan rate, which decreases to 2 to 3 mm/d for the dry season. Radioisotopic analysis confirms the microclimate-estimated 1:3 to 1:20 soil to plant /sup 137/Cs dry matter concentration ratio. This ratio exacerbates the dose to man from intake of food plants. Nephelometer measurements of airborne particulates presently indicate a minimum respiratory radiological dose.

Clegg, B.; Koranda, J.; Robinson, W.; Holladay, G.

1980-11-06T23:59:59.000Z

485

High-brightness switchable multiwavelength remote laser in air  

SciTech Connect (OSTI)

We demonstrate a harmonic-seeded switchable multiwavelength laser in air driven by intense midinfrared femtosecond laser pulses, in which population inversion occurs at an ultrafast time scale (i.e., less than {approx}200 fs) owing to direct formation of excited molecular nitrogen ions by strong-field ionization of inner-valence electrons. The bright multiwavelength laser in air opens the perspective for remote detection of multiple pollutants based on nonlinear optical spectroscopy.

Yao Jinping; Cheng Ya; Xu Zhizhan [State Key Laboratory of High Field Laser Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800 (China); Zeng Bin; Li Guihua; Chu Wei; Ni Jielei; Zhang Haisu [State Key Laboratory of High Field Laser Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800 (China); Graduate School of Chinese Academy of Sciences, Beijing 100080 (China); Xu Huailiang [State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun 130012 (China); Chin, See Leang [Center for Optics, Universite Laval, Quebec City, Quebec G1V 0A6 (Canada)

2011-11-15T23:59:59.000Z

486

Contact-Handled and Remote-Handled Transuranic Waste Packaging  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

Provides specific instructions for packaging and/or repackaging contact-handled transuranic (CH-TRU) and remote-handled transuranic (RH-TRU) waste in a manner consistent with DOE O 435.1, Radioactive Waste Management, DOE M 435.1-1 Chg 1, Radioactive Waste Management Manual, CH-TRU and RH-TRU waste transportation requirements, and Waste Isolation Pilot Plant (WIPP) programmatic requirements. Does not cancel other directives.

2011-08-09T23:59:59.000Z

487

Marine engine with water cooled fuel line from remote tank  

SciTech Connect (OSTI)

This patent describes a marine propulsion system. It comprises: a water cooled internal combustion engine, a remote fuel tank, a conduit connected between the fuel tank and the engine, the conduit having a first passage supplying fuel from the tank to the engine, the conduit having a second passage supplying cooling water from the engine towards the tank, the conduit having a third passage returning water from the second passage back to the engine.

Arms, J.F.

1990-07-10T23:59:59.000Z

488

A Centrifugal Contactor Design to Facilitate Remote Replacement  

SciTech Connect (OSTI)

Advanced designs of nuclear fuel recycling and radioactive waste treatment plants are expected to include more ambitious goals for solvent extraction based separations including; higher separations efficiency, high-level waste minimization, and a greater focus on continuous processes to minimize cost and footprint. Therefore, Annular Centrifugal Contactors (ACCs) are destined to play a more important role for such future processing schemes. This work continues the development of remote designs for ACCs that can process the large throughputs needed for future nuclear fuel recycling and radioactive waste treatment plants. A three stage, 12.5 cm diameter rotor module has been constructed and is being evaluated for use in highly radioactive environments. This prototype assembly employs three standard CINC V-05 clean-in-place (CIP) units modified for remote service and replacement via new methods of connection for solution inlets, outlets, drain and CIP. Hydraulic testing and functional checks were successfully conducted and then the prototype was evaluated for remote handling and maintenance. Removal and replacement of the center position V-05R contactor in the three stage assembly was demonstrated using an overhead rail mounted PaR manipulator. Initial evaluation indicates a viable new design for interconnecting and cleaning individual stages while retaining the benefits of commercially reliable ACC equipment. Replacement of a single stage via remote manipulators and tools is estimated to take about 30 minutes, perhaps fast enough to support a contactor change without loss of process equilibrium. The design presented in this work is scalable to commercial ACC models from V-05 to V-20 with total throughput rates ranging from 20 to 650 liters per minute.

David H. Meikrantz; Jack. D. Law; Troy G. Garn; Lawrence L. Macaluso

2011-03-01T23:59:59.000Z

489

Perfect State Transfer without State Initialization and Remote Collaboration  

E-Print Network [OSTI]

We present a perfect state transfer protocol via a qubit chain with the evolution governed by the $xx$ Hamiltonian. In contrast to the recent protocol announced in [Phys. Rev. Lett. {\\bf 101}, 230502 (2008)], our method does not demand any remote-cooperated initialization and sending classical information about measurement outcomes. We achieve the perfect state transfer only with the assumption of access to two spins at each end of the chain, while the initial state of the whole chain is irrelevant.

Marcin Markiewicz; Marcin Wiesniak

2009-02-06T23:59:59.000Z

490

Draft Environmental Assessment on the Remote-handled Waste Disposition  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Draft Environmental Assessment on the Remote-handled Waste Disposition Project available for public review and comment Draft Environmental Assessment on the Remote-handled Waste Disposition Project available for public review and comment The U.S. Department of Energy invites the public to review and comment on a draft environmental assessment that the Department issued today, for a proposal to process approximately 327 cubic meters of remote-handled waste currently stored at the Idaho National Laboratory. An additional five cubic meters of waste stored at the Hanford Site near Richland, Washington is also evaluated since it is reasonably foreseeable that a decision may be made in the future to send that waste to Idaho for treatment. The project is necessary to prepare the waste for legally-required disposal. Under the Department�s preferred alternative, workers would use sealed rooms called hot cells at the Idaho Nuclear Technology and Engineering Center (INTEC) to process the waste, treat it as necessary and repackage it so that it is ready for disposal. The document describes the modifications necessary to hot cells to perform the work.

491

Remote waste handling and feed preparation for Mixed Waste Management  

SciTech Connect (OSTI)

The Mixed Waste Management Facility (MWMF) at the Lawrence Livermore National Laboratory (LLNL) will serve as a national testbed to demonstrate mature mixed waste handling and treatment technologies in a complete front-end to back-end --facility (1). Remote operations, modular processing units and telerobotics for initial waste characterization, sorting and feed preparation have been demonstrated at the bench scale and have been selected for demonstration in MWMF. The goal of the Feed Preparation design team was to design and deploy a robust system that meets the initial waste preparation flexibility and productivity needs while providing a smooth upgrade path to incorporate technology advances as they occur. The selection of telerobotics for remote handling in MWMF was made based on a number of factors -- personnel protection, waste generation, maturity, cost, flexibility and extendibility. Modular processing units were selected to enable processing flexibility and facilitate reconfiguration as new treatment processes or waste streams are brought on line for demonstration. Modularity will be achieved through standard interfaces for mechanical attachment as well as process utilities, feeds and effluents. This will facilitate reconfiguration of contaminated systems without drilling, cutting or welding of contaminated materials and with a minimum of operator contact. Modular interfaces also provide a standard connection and disconnection method that can be engineered to allow convenient remote operation.

Couture, S.A.; Merrill, R.D. [Lawrence Livermore National Lab., CA (United States); Densley, P.J. [Science Applications International Corp., (United States)

1995-05-01T23:59:59.000Z

492

POSITION AVAILABLE: GIS/Remote Sensing Technician at UW-Madison Overview: A new position for a remote sensing and GIS technician is available in the  

E-Print Network [OSTI]

POSITION AVAILABLE: GIS/Remote Sensing Technician at UW-Madison Overview: A new position for a remote sensing and GIS technician is available in the Department of Forest and Wildlife Ecology imagery, especially from Landsat and MODIS sensors, and to acquire and process GIS datasets

Mladenoff, David

493

Remote Automatic Material On-Line Sensor  

SciTech Connect (OSTI)

Low cost NMR sensor for measuring moisture content of forest products. The Department of Energy (DOE) Industries of the Future (IOF) program seeks development and implementation of technologies that make industry more efficient--in particular, more energy-efficient. Quantum Magnetics, Inc. (QM), a wholly-owned subsidiary of GE Security, received an award under the program to investigate roles for low-cost Nuclear Magnetic Resonance (NMR) technology in furtherance of these goals. Most NMR systems are designed for high-resolution spectroscopy applications. These systems use intense magnetic fields produced by superconducting magnets that drive price and operating cost to levels beyond industry tolerance. At low magnetic fields, achievable at low cost, one loses the ability to obtain spectroscopic information. However, measuring the time constants associated with the NMR signal, called NMR relaxometry, gives indications of chemical and physical states of interest to process control and optimization. It was the purpose of this effort to investigate the technical and economic feasibility of using such low-field, low-cost NMR to monitor parameters enabling greater process efficiencies. The primary target industry identified in the Cooperative Development Agreement was the wood industry, where the moisture content of wood is a key process parameter from the time the cut tree