Development of a 220 kV/300 MVA superconductive fault current limiter  

Science Journals Connector (OSTI)

After we developed a saturated iron core type 35 kV/90 MVA superconductive fault current limiter and installed the device in a transmission network at Puji substation of China Southern Power Grid for live-grid operation in 2007, we continued our efforts in advancing this technology. A 220 kV/300 MVA device has been designed, manufactured and factory tested. This device differs from the 35 kV device in its form of electrical insulation even though the two devices have the same working principle and similar core structure. Improvements in the dc magnetization circuit and the cryogenic system were also achieved. This 220 kV/300 MVA superconductive fault current limiter has been installed and has passed all field tests at Shigezhuang substation in Tianjin, China. Trial operation is underway. This paper introduces the major design parameters, key functional specifications and some testing results of the device.

Y Xin; W Z Gong; H Hong; Y Q Gao; X Y Niu; J Y Zhang; Y W Sun; A L Ren; H Z Wang; L F Zhang; Q Li; Z Q Wei; L Z Wang; J B Cui; G J Niu; Z Q Xiong

2012-01-01T23:59:59.000Z

2

CRYOGENIC SYSTEM FOR A 35 KV/90 MVA SATURATED IRON?CORE SUPERCONDUCTING FAULT CURRENT LIMITER  

Science Journals Connector (OSTI)

A cryogenic system was built as an open system for a 35 kV/90 MVA saturated iron?core superconducting fault current limiter. It consists of an annular cylindrical liquid nitrogen dewar cryogenic pipes sensors valves and a control unit. A HTS dc bias coil was immersed with liquid nitrogen in the dewar. The control circuit constantly monitors the liquid nitrogen level and controls the supply of liquid nitrogen in accordance with the liquid nitrogen level change. Nitrogen vapor was directly released into the environment. Heat loss under different working conditions such as no magnetization current 150 A magnetization current and on?grid condition was measured to evaluate the performance of the system. As compared with no magnetization current of the dc bias coil evaporation of liquid nitrogen increases about 20% under the on?grid condition.

H. Hong; W. Z. Gong; B. Tian; J. Y. Zhang; X. M. Hu; J. Z. Wang; X. Y. Niu; Y. Wang; L. F. Zhang; Y. W. Sun; T. Q. Wu; Y. Xin

2010-01-01T23:59:59.000Z

3

HTS dc bias coil for 35 kV/90 MVA saturated iron-core fault current limiter  

Science Journals Connector (OSTI)

A superconductive coil with 141,000 ampere-turns designed magnetizing power, made of 17,600 meters of BSCCO 2223 HTS tapes, was fabricated and tested. This coil was built for a 35 kV/90 MVA saturated iron-core fault current limiter. Computer simulations on the performance of the coil were carried out using ANSYS. The critical current of the superconducting coil and the dc resistance of the coil, including the non-superconducting joints, were investigated. Spatial distribution of the magnetic field was measured and compared with the simulation results. In this paper, we will report the configuration and the key parameters of the coil as well as the experimental and simulation results.

W.Z. Gong; J.Y. Zhang; Z.J. Cao; H. Hong; B. Tian; Y. Wang; J.Z. Wang; X.Y. Niu; J. Qiu; S.H. Wang; Y. Xin

2008-01-01T23:59:59.000Z

4

MGSC EOR MVA  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Randy Locke, P.G. MVA Program, Assistant Coordinator Illinois State Geological Survey www.sequestration.org Illinois Basin - MVA Programs at Mumford Hills and Sugar Creek EOR Sites Overview * Monitoring, Verification and Accounting (MVA) Goals * MVA Efforts * Mumford Hills * Sugar Creek * Preliminary Observations at Sugar Creek * Kentucky Geological Survey * Glynn Beck, Kathy Takacs, Marty Parris * Illinois State Geological Survey

5

Design and Test Results of a 1 MVA Resistive Type Fault Current Limiter  

Science Journals Connector (OSTI)

The 1 MVA resistive type single phase AC fault current limiter (FCL) was build and successfully tested by capacitors battery discharge. FCL rated voltage is 3.5 kV, current 250 Arms. The 240 m of HTS tape (type SF12100 by SupePower) was used for FCL production. The FCL consists of 8 bifilar coils each wound onto glass-fiber 70 mm diameter tube and connected in series. The HTS tapes were additionally stabilized with Cu laminated highly resistive foil. During the tests of separate FCL coils at 380 V an excellent limiting performance was observed. Tested FCL coil was switched off after 75 ms, the maximum temperature at the HTS tape was less then 230 K, the recovery time was about 5 s.

V.E. Keilin; V.V. Lobyntsev; M.S. Novikov; S.J. Novikov; V.I. Shcherbakov

2012-01-01T23:59:59.000Z

6

Development and Test of a Prototype 100MVA Superconducting Generator  

SciTech Connect (OSTI)

In 2002, General Electric and the US Department of Energy (DOE) entered into a cooperative agreement for the development of a commercialized 100 MVA generator using high temperature superconductors (HTS) in the field winding. The intent of the program was to: • Identify and develop technologies that would be needed for such a generator. • Develop conceptual designs for generators with ratings of 100 MVA and higher using HTS technology. • Perform proof of concept tests at the 1.5 MW level for GE’s proprietary warm iron rotor HTS generator concept. • Design, build, and test a prototype of a commercially viable 100 MVA generator that could be placed on the power grid. This report summarizes work performed during the program and is provided as one of the final program deliverables.

Fogarty, James M.; Bray, James W.

2007-05-25T23:59:59.000Z

7

BE 400/18 kV Substation Renovation Project  

E-Print Network [OSTI]

The 400/18 kV SPS main substation was designed for the 400 GeV SPS project and was commissioned in 1974. It has been upgraded several times to form the present 400/66/18 kV SPS and LEP transmission power comprising 490 MVA and 240 MVAR installed power. The beginning of the LHC project and the obsolescence of the main elements, and consequently limited reliability, made it necessary to begin a complete renovation program. The new configuration of the substation will integrate the new compensator of reactive power efficiently into the 18 kV pulsed network. In this way the new compensator will facilitate the functioning of the pulsed network with the new loads and it will improve the performance of the electrical substation. The renovation program consists in a global reorganisation of the substation, with the total replacement of the 18 kV power equipment, a set up of new control and protection systems for the 18 kV and 400 kV section and the reconditioning of all the 400 kV equipment.

Vairo, Antonio

2001-01-01T23:59:59.000Z

8

Final Environmental Assessment of the Trentwood Loop to the Bell-Noxon 230-kV No.1 Line.  

SciTech Connect (OSTI)

The Bonneville Power Administration (BPA) proposes to construct a 2.7mile (4.3-kilometer), 230-kV, double-circuit steel structured trasmission line and to install a 230/115-kV, 300 MVA autotransformer with one 115-kV terminal at Trentwood in unincorporated Spokane County, WA, about 9 miles (14.5 kilometers) east of the City of Spokane. The Bell-Noxon 230-kV No. 1 Line would be opened near Trentwood. The proposed double-circuit line would be tied to the two opened ends of the Bell-Noxon line and brought into a common 230-kV bust at Trentwood Substation via the proposed double-circuit line; this is commonly known as looping a line into a substation. This report addresses the environmental impacts of various alternative solutions. 32 refs, 3 figs., 2 tabs.

United States. Bonneville Power Administration.

1982-05-01T23:59:59.000Z

9

Operation experiences with a 30 kV/100 MVA high temperature superconducting cable system  

Science Journals Connector (OSTI)

A superconducting cable based on Bi-2223 tape technology has been developed, installed and operated in the public network of Copenhagen Energy in a two-year period between May 2001 and May 2003. This paper gives a brief overview of the system and analyses some of the operation experiences. The aim of this demonstration project is to gain experience with HTS cables under realistic conditions in a live distribution network. Approximately 50?000 utility customers have their electric power supplied through the HTS cable. The cable system has delivered 226 GW h of energy and reached a maximum operating current of 1157 A. The operation experiences include over-currents of 6 kA due to faults on peripheral lines, commissioning, servicing and failure responses on the cooling system, continuous 24 h, 7 day per week monitoring and performance of the alarm system. The implications of these experiences for the future applications of HTS cable systems are analysed.

Ole Tønnesen; Manfred Däumling; Kim H Jensen; Svend Kvorning; Søren K Olsen; Chresten Træholt; Erling Veje; Dag Willén; Jacob Østergaard

2004-01-01T23:59:59.000Z

10

Microsoft Word - CCS MVA - Intro_2011.docx  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Monitoring, Verification, and Accounting Monitoring, Verification, and Accounting An effective monitoring, verification, and accounting (MVA) program is designed to confirm permanent storage of carbon dioxide (CO 2 ) in geologic formations through monitoring capabilities that are reliable and cost effective. Monitoring is an important aspect of CO 2 injection, since it focuses on a number of permanence issues. Monitoring technologies can be developed for surface, near-surface, and subsurface applications to ensure that injection, abandoned, and monitoring wells are structurally sound and that CO 2 will remain within the injection formation. Should Federal or state greenhouse gas accounting regulations and/or CO 2 emissions reductions be required, monitoring can be used to account for the quantity of CO

11

Design and Development of a 100 MVA HTS Generator for Commercial Entry  

SciTech Connect (OSTI)

In 2002, General Electric and the US Department of Energy (DOE) entered into a cooperative agreement for the development of a commercialized 100 MVA generator using high temperature superconductors (HTS) in the field winding. The intent of the program was to: (1) identify and develop technologies that would be needed for such a generator; (2) develop conceptual designs for generators with ratings of 100 MVA and higher using HTS technology; (3) perform proof of concept tests at the 1.5 MW level for GE's proprietary warm iron rotor HTS generator concept; and (4) design, build, and test a prototype of a commercially viable 100 MVA generator that could be placed on the power grid. This report summarizes work performed during the program and is provided as one of the final program deliverables. The design for the HTS generator was based on GE's warm iron rotor concept in which a cold HTS coil is wound around a warm magnetic iron pole. This approach for rotating HTS electrical machinery provides the efficiency benefits of the HTS technology while addressing the two most important considerations for power generators in utility applications: cost and reliability. The warm iron rotor concept uses the least amount of expensive HTS wire compared to competing concepts and builds on the very high reliability of conventional iron core stators and armature windings.

None

2007-06-07T23:59:59.000Z

12

Microsoft PowerPoint - Overview of MVA(Hovorka).ppt  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Surveillance of a Geologic Surveillance of a Geologic Sequestration Project: Monitoring Validation Accounting Susan D. Hovorka Gulf Coast Carbon Center Bureau of Economic Geology University of Texas at Austin Management of SECARB Management of SECARB Gulf Coast Carbon Gulf Coast Carbon Center Center Gulf Coast Gulf Coast Carbon Center Carbon Center Sponsors Sponsors University of Texas at Austin SECARB coal seam Geological Survey of Alabama Virginia Tech SECARB Plant Daniels EPRI Southern Co ARI Other SECARB tests Questions * What are techniques for MVA? - techniques purely (or mostly) research oriented - techniques that ensure project integrity * Do we have MVA techniques that can be used today to ensure the integrity of GS projects and detect leaks if they are occurring? * What else do we need to learn about MVA?

13

Back-to-Back Energization of a 60kV Cable Network -Inrush Currents Phenomenon  

E-Print Network [OSTI]

transmission lines with a rated voltage equal to and below 150kV must be put underground, in order to reduce's energization. Fig. 1. ENV 60kV Network map Fig. 2. Single Line Diagram of the analyzed area The knowledge1 Back-to-Back Energization of a 60kV Cable Network - Inrush Currents Phenomenon F. Faria da Silva

Silva, Filipe Faria Da

14

,"Geographic Area",,,"Voltage",,,"Capacity Rating (MVa)","In...  

U.S. Energy Information Administration (EIA) Indexed Site

,"U","WECC","AZN","AC",230,230,0,"applicationvnd.ms-excel","White Tanks AZ","Rudd AZ",6,,,,0,,,0,0,803,,100 ,"U","WECC","AZN","AC",230,230,0,"application...

15

,"Geographic Area",,,"Voltage",,,"Capacity Rating (MVa)","In...  

U.S. Energy Information Administration (EIA) Indexed Site

,"U","WECC","AZN","AC",230,230,0,"applicationvnd.ms-excel","White Tanks AZ","Rudd AZ",6,"OH",,,0,,,0,0,803,,0 ,"U","WECC","AZN","AC",230,230,0,"application...

16

,"Geographic Area",,,"Voltage",,,"Capacity Rating (MVa)","In...  

U.S. Energy Information Administration (EIA) Indexed Site

4,"ACSR",2,1,2,9324,"I",0 ,"U","ECAR",,"AC",345,345,1195,"applicationvnd.ms-excel","JK Smith","Spurlock Avon",17.5,"OH",,,954,"ACSR",2,1,1,5580,"C",0 ,"U","ECAR",,"AC",765,765,2...

17

,"Geographic Area",,,"Voltage",,,"Capacity Rating (MVa)","In...  

U.S. Energy Information Administration (EIA) Indexed Site

,"ACSR",1,1,1,-19,"I1",0 ,"U","SERC","SOU","AC",230,230,807,"applicationvnd.ms-excel","Smith","Laguna Beach",14,"OH","P","S",1351,"OT",1,2,2,7801,"I1",0 ,"U","SERC","SOU","AC",230...

18

,"Geographic Area",,,"Voltage",,,"Capacity Rating (MVa)","In...  

U.S. Energy Information Administration (EIA) Indexed Site

,0,0,0,0,0,"DLCO","I",100 ,"U","RFC",0,"AC",345,345,1195,"applicationvnd.ms-excel","JK Smith","Spurlock Avon",17.5,"OH","H","S",954,"ACSR",2,2,2,0,"EKPC","C",100...

19

,"Geographic Area",,,"Voltage",,,"Capacity Rating (MVa)","In...  

U.S. Energy Information Administration (EIA) Indexed Site

Construction","Reliability",0 ,"US","SERC","-","AC","200-299",230,602,6,2011,"Lansing Smith","Laguna Beach",14,"OH - Overhead","steel","single pole",1351,"ACSR","Single",1,1,9999...

20

,"Geographic Area",,,"Voltage",,,"Capacity Rating (MVa)","In...  

U.S. Energy Information Administration (EIA) Indexed Site

Corporation","Cooperative",100 ,"U","SERC","TVA","AC",345,345,1947,"6-2007","J.K. Smith","North Clark",18,"OH - Overhead","H-frame","steel",954,"ACSR","Double",2,2,5580,"East...

Note: This page contains sample records for the topic "kv rating mva" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

,"Geographic Area",,,"Voltage",,,"Capacity Rating (MVa)","In...  

U.S. Energy Information Administration (EIA) Indexed Site

,"OH",,,5027,"DPL","I" ,"US","SERC","Central","AC",345,345,535,39507,"Hardin Co.","Smith OMU",-66,"OH","H-frame","wood",954,"ACSR","Double",1,2,10171,"E.ON U.S. Services Inc....

22

In-Situ MVA of CO2 Sequestration Using Smart Field Technology  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

In-Situ MVA of CO 2 Sequestration Using Smart Field Technology Background Through its core research and development program administered by the National Energy Technology...

23

In-Situ MVA of CO2 Sequestration Using Smart Field Technology  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

In-Situ MVA of CO In-Situ MVA of CO 2 Sequestration Using Smart Field Technology Background Through its core research and development program administered by the National Energy Technology Laboratory (NETL), the U.S. Department of Energy (DOE) emphasizes monitoring, verification, and accounting (MVA), as well as computer simulation and risk assessment, of possible carbon dioxide (CO 2 ) leakage at CO 2 geologic storage sites. MVA efforts focus on the development and deployment of technologies that can provide an accurate accounting of stored CO 2 , with a high level of confidence that the CO 2 will remain stored underground permanently. Effective application of these MVA technologies will ensure the safety of geologic storage projects with respect to both human health and the environment, and can provide the basis for establishing

24

500-kV Central Ferry Substation ...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Central Ferry Substation in Garfield County, Wash., to BPA's 500-kV Lower Monumental Substation in Walla Walla County, Wash. BPA is currently considering two routing...

25

150-kV, 80-A SOLID STATE POWER SUPPLY FOR NEUTRAL BEAM INJECTION  

E-Print Network [OSTI]

a zero failure rate. That SCR's may be connected in series120 kV operating systems. That a SCR switched capacitor bank21 Franck, J. V. , et al. , "An SCR Sedes Switch and Impulse

Owren, H.

2011-01-01T23:59:59.000Z

26

14 kV single-phase superconducting fault current limiter based on YBCO films  

Science Journals Connector (OSTI)

We present the fabrication and short circuit test results of a 14 kV single-phase resistive superconducting fault current limiter (SFCL) based on \\{YBa2Cu3O7\\} (YBCO) films. Individual components were processed using the 4? YBCO films and have the rated voltage and current of 600 V and 35 A at 77 K, respectively. Twenty four components, eight components in series and three lines in parallel, make a module having the rated voltage and current of 4.8 kV and 105 A, respectively. Three modules were assembled in series to produce the SFCL working at 77 K, a 14 kV single-phase machine for the 22.9 kV Y–Y grid. short circuit tests were successfully conducted in an accredited test facility with the maximum fault currents up to 14.1 kAP. All components quenched together upon faults and shared the rated voltage evenly without any supplementary device between the modules. This proves that the SFCL based on YBCO films may not only work reliably at 22.9 kV, but also provide technical feasibility for higher voltage application including the transmission grids.

J. Sim; K.B. Park; H.R. Kim; J.S. Kang; B.W. Lee; H.M. Kim; I.S. Oh; O.B. Hyun

2007-01-01T23:59:59.000Z

27

A source of reactive power at a 35-kV substation of the Vankor oilfield  

Science Journals Connector (OSTI)

An SRP-35/10/10 source of reactive power based on a magnetically controlled RTMU-10000/35-UHL1-series shunt reactor and a capacitor bank rated at 10 MV A at voltage 35 kV is described in this work. It was put int...

B. I. Bazylev; M. A. Bryantsev; S. V. Dyagileva…

2012-03-01T23:59:59.000Z

28

Design studies for the Mead-Phoenix 500 kV AC transmission project  

SciTech Connect (OSTI)

The Mead-Phoenix 500 kV ac line is 243 miles long and runs parallel to the existing Mead-Liberty 345 kV line. This line is planned for 70% series and 70% shunt compensation; it also incorporates the first application of a 50 kV phase shifting transformer that enables a 1,300 MW transmission capacity. This paper presents the design studies that were undertaken in arriving at the equipment ratings and insulation levels that lead to the equipment specifications. The shunt reactor switching requirements utilizing MOV across the breaker, line switching with line connected arresters and the breaker transient recovery voltage are also dealt with in the paper.

Thallam, R.S.; Lundquist, T.G.; Gerlach, D.W. [Salt River Project, Phoenix, AZ (United States)] [Salt River Project, Phoenix, AZ (United States); Atmuri, S.R. [Teshmont Consultants Inc., Winnipeg, Manitoba (Canada)] [Teshmont Consultants Inc., Winnipeg, Manitoba (Canada); Selin, D.A. [Arizona Public Service Co., Phoenix, AZ (United States)] [Arizona Public Service Co., Phoenix, AZ (United States)

1995-10-01T23:59:59.000Z

29

Development of a thyristor valve for next generation 500kV HVDC transmission systems  

SciTech Connect (OSTI)

A high voltage thyristor valve is the basic component of an HVDC transmission system. Development of a 500kV valve for next generation HVDC transmission systems is described. First, the power loss of the valve is analyzed to decide a reasonable wafer size for the light triggered thyristor. From these results, a six inch diameter wafer size is selected. The light triggered thyristor, with ratings of 8kV and 3.5kA, is developed using the six inch wafer. The designing of the valve employing the thyristor and test results with the prototype valve prove that a 500kV valve can be realized by the design method.

Hasegawa, T. [Kansai Electric Power Co., Inc., Osaka (Japan)] [Kansai Electric Power Co., Inc., Osaka (Japan); Yamaji, K. [Shikoku Electric Power Co., Inc., Takamatsu (Japan)] [Shikoku Electric Power Co., Inc., Takamatsu (Japan); Irokawa, H. [Electric Power Development Co., Ltd., Tokyo (Japan)] [Electric Power Development Co., Ltd., Tokyo (Japan); Shirahama, H.; Tanaka, C.; Akabane, K.

1996-10-01T23:59:59.000Z

30

Vibration Proof Construction of 1000kV Electron Microscope  

Science Journals Connector (OSTI)

......University Press 1970 other ORIGINAL Vibration Proof Construction of 1000kV Electron...with the center of gravity. That is, a vibration proof hanging console was made as a method...protecting a 1000kV Electron Microscope from vibration, and this allowed the whole instrument......

Yoshio SAKITANI; Susumu OZASA

1970-01-01T23:59:59.000Z

31

Combined kV and MV imaging for real-time tracking of implanted fiducial markers  

SciTech Connect (OSTI)

In the presence of intrafraction organ motion, target localization uncertainty can greatly hamper the advantage of highly conformal dose techniques such as intensity modulated radiation therapy (IMRT). To minimize the adverse dosimetric effect caused by tumor motion, a real-time knowledge of the tumor position is required throughout the beam delivery process. The recent integration of onboard kV diagnostic imaging together with MV electronic portal imaging devices on linear accelerators can allow for real-time three-dimensional (3D) tumor position monitoring during a treatment delivery. The aim of this study is to demonstrate a near real-time 3D internal fiducial tracking system based on the combined use of kV and MV imaging. A commercially available radiotherapy system equipped with both kV and MV imaging systems was used in this work. A hardware video frame grabber was used to capture both kV and MV video streams simultaneously through independent video channels at 30 frames per second. The fiducial locations were extracted from the kV and MV images using a software tool. The geometric tracking capabilities of the system were evaluated using a pelvic phantom with embedded fiducials placed on a moveable stage. The maximum tracking speed of the kV/MV system is approximately 9 Hz, which is primarily limited by the frame rate of the MV imager. The geometric accuracy of the system is found to be on the order of less than 1 mm in all three spatial dimensions. The technique requires minimal hardware modification and is potentially useful for image-guided radiation therapy systems.

Wiersma, R. D.; Mao Weihua; Xing, L. [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California 94305-5847 (United States)

2008-04-15T23:59:59.000Z

32

RATES  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Planning & Projects Planning & Projects Power Marketing Rates You are here: SN Home page > Power Marketing > RATES Rates and Repayment Services Rates Current Rates Power Revenue Requirement Worksheet (FY 2014) (Oct 2013 - Sep 2014) (PDF - 30K) PRR Notification Letter (Sep 27, 2013) (PDF - 959K) FY 2012 FP% True-Up Calculations(PDF - 387K) Variable Resource Scheduling Charge FY12-FY16 (October 1, 2012) PRR Forecast FY14-FY17 (May 23, 2013) (PDF - 100K) Forecasted Transmission Rates (May 2013) (PDF - 164K) Past Rates 2013 2012 2011 2010 2009 Historical CVP Transmission Rates (April 2013) (PDF - 287K) Rate Schedules Power - CV-F13 - CPP-2 Transmission - CV-T3 - CV-NWT5 - PACI-T3 - COTP-T3 - CV-TPT7 - CV-UUP1 Ancillary - CV-RFS4 - CV-SPR4 - CV-SUR4 - CV-EID4 - CV-GID1 Federal Register Notices - CVP, COTP and PACI

33

RATES  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Marketing > RATES Marketing > RATES RATES Current Rates Past Rates 2006 2007 2008 2009 2010 2011 2012 Rates Schedules Power CV-F13 CPP-2 Transmissions CV-T3 CV-NWT5 PACI-T3 COTP-T3 CV-TPT7 CV-UUP1 Ancillary CV-RFS4 CV-SPR4 CV-SUR4 CV-EID4 CV-GID1 Future and Other Rates SNR Variable Resource Scheduling Charge FY12-FY16 (October 1, 2012) SNR Rates Process Calendar (PDF - 171K) Procedures Informal Process Transmission Action Items List (PDF - 144K) Power Action Item List updated on 4-27-10 (PDF - 155K) Power Action Item List (Quick links to relevant documents) Formal Process Rates Brochure (01/11/2011) (PDF - 900K) Appendix A - Federal Register Notice (01/03/2011) (PDF - 8000K) Appendix B - Central Valley Project Power Repayment Study (PDF - 22,322K) Appendix C - Development of the CVP Cost of Service Study (PDF - 2038K)

34

RATES  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

RATES RATES Rates Document Library SNR Rates Process Calendar (PDF - 171K) Procedures Informal Process Transmission Action Items List (PDF - 144K) Power Action Item List updated on 4-27-10 (PDF - 155K) Power Action Item List (Quick links to relevant documents) Formal Process Rates Brochure (01/11/2011) (PDF - 900K) Appendix A - Federal Register Notice (01/03/2011) (PDF - 8000K) Appendix B - Central Valley Project Power Repayment Study (PDF - 22,322K) Appendix C - Development of the CVP Cost of Service Study (PDF - 2038K) Appendix D - Western Transmission System Facilities Map (PDF - 274K) Appendix E - Estimated FY12 FP and BR Customer (PDF - 1144K) Appendix F - Forecasted Replacements and Additions FY11 - FY16 (PDF - 491K) Appendix G - Definitions (PDF - 1758K) Appendix H - Acronyms (PDF - 720K)

35

Development and Deployment of a Compact Eye-safe Scanning Differential Absorption Lidar (DIAL) for Spatial Mapping of Carbon Dioxide for MVA at Geologic Carbon Sequestration Sites  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Deployment of a Deployment of a Compact Eye-safe Scanning Differential Absorption Lidar (DIAL) for Spatial Mapping of Carbon Dioxide for MVA at Geologic Carbon Sequestration Sites Description Through its core research and development program administered by the National Energy Technology Laboratory (NETL), the U.S. Department of Energy (DOE) emphasizes monitoring, verification, and accounting (MVA), as well as computer simulation, of possible carbon dioxide (CO 2 ) leakage at CO 2

36

Alvey-Fairview No.1, 230 kV Rebuild  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Power Administration is planning to rebuild the Alvey Fairview No. 1, 230kV transmission line, construction is scheduled for 2013 or 2014. The 97.46 mile transmission line...

37

16. Recording of Absarption Spectra (Absorption Accessory kit t (55466); 30 kV; 0.08 mA, room normally  

E-Print Network [OSTI]

16. Recording of Absarption Spectra (Absorption Edge) Accessory kit t (55466); 30 kV; 0.08 mA, room set to 30 kV7 16.4. Tabulate counts, I,from 20° (2 8)to 40' at 1' intervals. Fig. 1 8 1 16.5. Locate ktween the K,- and the Kg-line of copper, so that the transmission rate of the Kg-line is very weak while

Browder, Tom

38

Análise metodológica para a conversão de linhas de distribuição de 34,5 KV para 69 KV.  

E-Print Network [OSTI]

??Este trabalho visa apresentar uma análise metodológica para viabilizar a realização da repotenciação, elevando a classe de tensão de linhas de distribuição de 34,5 kV… (more)

Patrick Santos de Oliveira

2011-01-01T23:59:59.000Z

39

69 kV shunt capacitor bank specification considerations  

SciTech Connect (OSTI)

PSI has standardized on the 69 kv ungrounded star, 7.2 mvar or multiple of the 7.2 mvar shunt capacitor bank for var control. This document defines the considerations to be addressed when specifying a 69 kv ungrounded capacitor bank and for providing suitable protection. The design goal is to provide a bank that is reliable and meets operational requirements at minimum cost with standard components. The bank components will be discussed separately. This paper defines the considerations for specifying capacitor banks to minimize cost, improve reliability and help standardize design. The components making up the bank will be individually discussed with special emphasis on the protection and control.

Fenner, G.E. (PSI Energy, Inc., Plainfield, IN (US))

1992-01-01T23:59:59.000Z

40

Categorical Exclusion (CX) Determination Proposed Action: Elliot 115kV/43.8kV Transmission Substation Construction and Elliot  

Broader source: Energy.gov (indexed) [DOE]

Elliot 115kV/43.8kV Transmission Substation Construction and Elliot Elliot 115kV/43.8kV Transmission Substation Construction and Elliot 43.8kV Transmission Line. Description of Proposed Action: The Central Power Electric Cooperative (Central Power) is proposing a new substation near Elliot, ND to be owned and operated by Western under Western's Valley City to Forman 115kV transmission line in addition to 8 miles of new 43.8kV transmission line to connect the new substation to Dakota Valley Electric's (a Central Power member) North Milnor substation. Number and Title of Categorical Exclusions Being Applied: 10 CFR 1021.410 Subpart D, Appendix B, B4.l1: Construction of electric power substations ... or modification of existing substations and support facilities. Regulatory Requirements for CX Determination: The DOE Guidelines for Compliance with

Note: This page contains sample records for the topic "kv rating mva" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Survey of Magnetic Fields Near BPA 230-kV and 500-kV Transmission Lines.  

SciTech Connect (OSTI)

The purpose of this study was to characterize typical levels and variability of 60Hz magnetic fields at the centerline and edge of right-of-way of Bonneville Power Administration (BPA) 230-kV and 500-kV transmission lines. This was accomplished by taking magnetic field measurements at over 800 spans in Oregon and Washington. The spans were sampled using a stratified random sampling procedure with region (East vs. West), voltage (230-kV vs 500-kV), and circuit configuration as strata. There were five different circuit configuration groups for each region/voltage category requiring a total of 200 strata. Magnetic field measurements were taken at 13 locations under each span using an EMDEX-C as a survey meter. Additional information recorded for each span included conductor height (at 10 locations), right-of-way width, longitudinal and lateral slope, time of day, vegetation, terrain, weather conditions, temperature, wind speed, span length and presence of other lines in the corridor. 9 refs., 17 figs., 26 tabs.

Perrin, Nancy; Aggarwal, Rajinder Pal; Bracken, T. Daniel

1991-05-20T23:59:59.000Z

42

ETM (Distribution Network Automation on 10 kV cable line stations...  

Open Energy Info (EERE)

ETM (Distribution Network Automation on 10 kV cable line stations) (Smart Grid Project) Jump to: navigation, search Project Name ETM (Distribution Network Automation on 10 kV cable...

43

Docket No. EO-05-01: Further Notice of 230kV Circuit Planned Outages |  

Broader source: Energy.gov (indexed) [DOE]

Further Notice of 230kV Circuit Planned Further Notice of 230kV Circuit Planned Outages Docket No. EO-05-01: Further Notice of 230kV Circuit Planned Outages Docket No. EO-05-01. Pursuant to the United States Department of Energy Order No. 202-05-03, issued December 20, 2005 directing Mirant Potomac River to generate electricity at Potomac River Generating Station, PEPCO hereby files this Further Notice of 230kV Circuit Planned Outages. Docket No. EO-05-01: Further Notice of 230kV Circuit Planned Outages More Documents & Publications Further Notice of 230kV Circuit Planned Outages Re: Potomac River Generating Station Department of Energy, Case No. EO-05-01: Potomac Electric Power Company (PEPCO) Concerning Planned Outages of the 230 kV circuits Re: Potomac River Generating Station Department of Energy Case No.

44

Further Notice of 230kV Circuit Planned Outages | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Further Notice of 230kV Circuit Planned Outages Further Notice of 230kV Circuit Planned Outages Further Notice of 230kV Circuit Planned Outages Docket No. EO-05-01. Order No. 202-05-03: Pursuant 10 the United States Department of Energy "DOE") Order No. 102-05-3, issued December 20, 2005 ("DOE Potomac River Order''), Pepco hereby files this Further Notice Of 230kV Circuit Planned Outages serving the Potomac River Substation, and through thaI station, the District of Columbia. Further Notice of 230kV Circuit Planned Outages More Documents & Publications Re: Potomac River Generating Station Department of Energy, Case No. EO-05-01: Potomac Electric Power Company (PEPCO) Concerning Planned Outages of the 230 kV circuits Docket No. EO-05-01: Further Notice of 230kV Circuit Planned Outages

45

Further Notice of 230kV Circuit Planned Outages | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Further Notice of 230kV Circuit Planned Outages Further Notice of 230kV Circuit Planned Outages Further Notice of 230kV Circuit Planned Outages Docket No. EO-05-01. Order No. 202-05-03: Pursuant 10 the United States Department of Energy "DOE") Order No. 102-05-3, issued December 20, 2005 ("DOE Potomac River Order''), Pepco hereby files this Further Notice Of 230kV Circuit Planned Outages serving the Potomac River Substation, and through thaI station, the District of Columbia. Further Notice of 230kV Circuit Planned Outages More Documents & Publications Docket No. EO-05-01: Further Notice of 230kV Circuit Planned Outages Re: Potomac River Generating Station Department of Energy, Case No. EO-05-01: Potomac Electric Power Company (PEPCO) Concerning Planned Outages of the 230 kV circuits

46

Detailed design of a 13 kA 13 kV dc solid-state turn-off switch  

SciTech Connect (OSTI)

An experimental facility for the study of electromagnetic effects in the First Wall-Blanket-shield (FWBS) systems of fusion reactors has been constructed at Argonne National Laboratory (ANL). In a test volume of 0.76 m/sup 3/, a vertical, pulsed 5 kG dipole field (B < 320 kGs/sup -1/) is perpendicular to a 10 kG solenoid field. Power supplies of 2.75 MW at 550 V dc and 5.5 MW at 550 V dc and a solid-state switch rated at 13 kA and 13 kV (169 MW) control the pulsed magnetic fields. The total stored energy in the coils is 2.6 MJ. This paper describes the design and construction features of the solid-state switching circuit which turns off a dc of 13 kA in approximately 82 ..mu..s and holds off voltages of < 13 kV.

Praeg, W.F.

1985-01-01T23:59:59.000Z

47

Buffalo Flat Service 115-KV Transmission Project : Environmental Assessment.  

SciTech Connect (OSTI)

BPA, in conjunction with Midstate Electric Cooperative (Midstate), proposed to construct two sections of a new 115-kV transmission line in central Oregon: one section from BPA's LaPine Substation to Midstate's Fort Rock Substation (BPA), and the other from Fort Rock Substation to the proposed US Air Force radar transmitter site at Buffalo Flat (Midstate). The proposed line would be a total of about 74 miles long, and of either wood or steel single-pole construction; it would parallel existing corridors and/or roads for much of the distance. 23 refs., 6 figs., 5 tabs.

United States. Bonneville Power Administration.

1987-07-01T23:59:59.000Z

48

Wild Horse 69-kV transmission line environmental assessment  

SciTech Connect (OSTI)

Hill County Electric Cooperative Inc. (Hill County) proposes to construct and operate a 69-kV transmission line from its North Gildford Substation in Montana north to the Canadian border. A vicinity project area map is enclosed as a figure. TransCanada Power Corporation (TCP), a Canadian power-marketing company, will own and construct the connecting 69-kV line from the international border to Express Pipeline`s pump station at Wild Horse, Alberta. This Environmental Assessment is prepared for the Department of Energy (DOE) as lead federal agency to comply with the requirements of the National Environmental Policy Act (NEPA), as part of DOE`s review and approval process of the applications filed by Hill County for a DOE Presidential Permit and License to Export Electricity to a foreign country. The purpose of the proposed line is to supply electric energy to a crude oil pump station in Canada, owned by Express Pipeline Ltd. (Express). The pipeline would transport Canadian-produced oil from Hardisty, Alberta, Canada, to Caster, Wyoming. The Express Pipeline is scheduled to be constructed in 1996--97 and will supply crude oil to refineries in Wyoming and the midwest.

NONE

1996-12-01T23:59:59.000Z

49

Microsoft Word - Deering Lake-Eckley 115-kV Transmission Line...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Deering Lake-Eckley 115-kV Transmission Line Structure Replacements Yuma County, Colorado 1 A. Brief Description of Proposal: Western Area Power Administration (Western) proposes...

50

EIS-0344: Grand Coulee-Bell 500 kV Transmission Line  

Broader source: Energy.gov [DOE]

This EIS analyzes DOE's proposed action for the construction and operation of the proposed Grand Coulee-Bell 500-kV Transmission Line Project.

51

Mead-Liberty 345-kV Transmission Line Access Road Maintenance...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

2 Mead-Liberty 345-kV Transmission Line Access Road Maintenance and Localized Vegetation Management Maricopa County, Arizona Categorical Exclusion Continuation Sheet Project...

52

Bouse Hills Pumping Plant to Harcuvar 115-kV Transmission Line  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Bouse Hills Pumping Plant to Harcuvar 115-kV Transmission Line Inset Structure Installation La Paz County, Arizona Categorical Exclusion Continuation Sheet Special Conditions 1....

53

1.2 MVA High-Tc Superconducting Fault Current Limiter  

Science Journals Connector (OSTI)

A 3-phase high Tc superconducting fault current limiter with a rated power of 1.2 ... a special partial melt process. The nominal current and voltage of the device are 70 ... 3-phase short circuit tests with a pr...

W. Paul; M. Chen; M. Lakner; J. Rhyner; L. Widenhorn…

1998-01-01T23:59:59.000Z

54

Notification of Planned 230kV Outage at Potomac River Generating Station |  

Broader source: Energy.gov (indexed) [DOE]

Notification of Planned 230kV Outage at Potomac River Generating Notification of Planned 230kV Outage at Potomac River Generating Station Notification of Planned 230kV Outage at Potomac River Generating Station Docket No. EO-05-01. In accordance with DOE Order No. 202-05-03 Pepco is required to provide notification of any and all 230kV planned outages at Potomac River Generating Station. On Tuesday February 20, 2007 Potomac Electric Power Company (Pepco) will be taking a planned outage on the 23106 high voltage circuit between the Palmer's Corner Substation and the Potomac River Generating Station. Notification of Planned 230kV Outage at Potomac River Generating Station More Documents & Publications Re: Potomac River Generating Station Department of Energy Case No. EO-05-01: Advanced Notice of Power Outages. Special Environmental Analysis For Actions Taken under U.S. Department of

55

Progress of the EAST Project in China Y.X. Wan, P.D. Weng, J.G. Li, D.M. Gao, S.T. Wu  

E-Print Network [OSTI]

machine hall and other appurtenant buildings · 110 kV/83 MVA transmission line and transformer substation

56

EA-1679: Grand Coulee's Third Powerplant 500-kV Transmission Line  

Broader source: Energy.gov (indexed) [DOE]

79: Grand Coulee's Third Powerplant 500-kV Transmission Line 79: Grand Coulee's Third Powerplant 500-kV Transmission Line Replacement Project, Grant and Okanogon Counties, Washington EA-1679: Grand Coulee's Third Powerplant 500-kV Transmission Line Replacement Project, Grant and Okanogon Counties, Washington Summary This EA evaluates potential environmental impacts from the construction and operation of six new 500-kV overhead transmission lines to replace six existing underground lines at Grand Coulee Dam. DOE's Bonneville Power Administration (BPA), a cooperating agency, was asked by the U. S. Department of the Interior's Bureau of Reclamation to design and construct the proposed new transmission lines. A Finding of No Significant Impact was issued by BPA in December 2011. BPA website: http://efw.bpa.gov/environmental_services/Document_Library/Grand_Coulee/

57

EA-1665: Davis-Kingman 69-kV Transmission Line Rebuild Project, Arizona |  

Broader source: Energy.gov (indexed) [DOE]

65: Davis-Kingman 69-kV Transmission Line Rebuild Project, 65: Davis-Kingman 69-kV Transmission Line Rebuild Project, Arizona EA-1665: Davis-Kingman 69-kV Transmission Line Rebuild Project, Arizona Overview Western plans to rebuild a 26.6-mile-long portion of the existing 27.3-mile-long Davis-Kingman Tap 69-kV Transmission Line within the existing ROW in order to improve the reliability of the transmission service. The line has been in service well beyond its projected service life, customer load on the line has increased considerably over the years, and reliability has decreased due to natural aging, extreme weather exposure, vandalism, and lightning strikes. The western-most 0.7 mile of the existing line was rebuilt as part of the Davis Dam Switchyard in 2010. Public Comment Opportunities No public comment opportunities available at this time.

58

ZigBee Performance in 400 KV Air Insulated Power Substation  

Science Journals Connector (OSTI)

An experimental assessment of the impact of the electromagnetic environment of a 400 kV substation on the performance of ZigBee equipment is ... the performance of ZigBee equipment deployed in the substation with...

Qingshan Shan; I A Glover; P J Moore…

2010-01-01T23:59:59.000Z

59

ESS 2012 Peer Review - 6.5 kV Silicon Carbide Half-Bridge Power...  

Broader source: Energy.gov (indexed) [DOE]

a 5 kV DC-Link voltage which will greatly impact Storage Systems by reducing costs of power conversion stages Impact current system designs as well as create a platform for...

60

Grounding of a 230 kV Transmission line over a Limestone Ridge.  

E-Print Network [OSTI]

?? This thesis is a case study of a 230 kV transmission line in Lao P.D.R. Grounding of electrical systems is essential for safety and… (more)

Grubbström, Emma

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "kv rating mva" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Bonneville Power Administration Grand Coulee-Bell 500-kV Transmission Line Project Record of Decision  

Broader source: Energy.gov (indexed) [DOE]

Grand Coulee-Bell 500-kV Transmission Line Project Grand Coulee-Bell 500-kV Transmission Line Project Record of Decision Decision The Bonneville Power Administration (BPA) has decided to construct the proposed Grand Coulee-Bell 500-kV Transmission Line Project in Douglas, Grant, Lincoln, and Spokane Counties, Washington. BPA has decided to implement the proposed action identified in the Grand Coulee-Bell 500-kV Transmission Line Project Final Environmental Impact Statement (DOE/EIS-0344, December 2002). The proposed action consists of constructing a new 500- kilovolt (kV) transmission line between the Bureau of Reclamation's (BOR) Grand Coulee 500- kV Switchyard near Grand Coulee, Washington, and BPA's Bell Substation near Spokane, a distance of 84 miles. The proposed action involves removing an existing 115-kV transmission

62

A 25 KV/10A PULSER FOR DRIVING A HIGH-POWER PIERCE ELECTRON GUN  

E-Print Network [OSTI]

A 25 KV/10A PULSER FOR DRIVING A HIGH-POWER PIERCE ELECTRON GUN J. J. Barroso, J. O. Rossi, H-tube pulser to drive a high-power electron gun. The tube includes a 2.0µF/100kV capacitor bank whose discharge is controlled by a tetrode tube connected to the gun cathode. Typical measured operating parameters are 3

63

Western Area Power Administration, Desert Southwest Region Facilities Ratings Project  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Facilities Ratings Project Facilities Ratings Project Hoover-Mead #1 and #5 230-kV and Mead-Marketplace 500-kV Transmission Lines Continuation Sheet Project Description (Continued) Hoover-Mead # 1 230-kV Transmission Line Along the Hoover-Mead #1 230-kV transmission line, the existing line will be reconductored between structures 0/4 and 4/2, about 3.5 linear miles. Structure 0/4 is located northeast of Mead Substation; structure 4/2 is located southeast of Boulder City Tap. The scope of work for the reconductoring includes the following: * At tangent structures (where there is no change in the angle of the transmission line), pulleys or travelers will be installed where the existing conductor attaches to the insulator. The old conductor will be pulled out through the travelers and new wire will be pulled in. A bucket truck

64

Marys Lake 69/115-kV transmission line upgrade and substation expansion projects  

SciTech Connect (OSTI)

Western Area Power Administration (Western) and the Platte River Power Authority (Platte River) propose to upgrade portions of the existing electric transmission and substation system that serves the Town of Estes Park, Colorado. The existing transmission lines between the Estes Power Plant Switchyard and the Marys Lake Substation include a 115,000 volt (115-kV) line and 69,000 volt (69-kV) line. Approximately one mile is a double-circuit 115/69-kV line on steel lattice structures, and approximately two miles consists of separate single-circuit 115-kV and a 69-kV lines, constructed on wood H-Frame structures. Both lines were constructed in 1951 by the US Bureau of Reclamation. The existing transmission lines are on rights-of-way (ROW) that vary from 75 feet to 120 feet and are owned by Western. There are 48 landowners adjacent to the existing ROW. All of the houses were built adjacent to the existing ROW after the transmission lines were constructed. Upgrading the existing 69-kV transmission line between the Marys Lake Substation and the Estes Power Plant Switchyard to 115-kV and expanding the Marys Lake Substation was identified as the most effective way in which to improve electric service to Estes Park. The primary purpose and need of the proposed project is to improve the reliability of electric service to the Town of Estes Park. Lack of reliability has been a historical concern, and reliability will always be less than desired until physical improvements are made to the electrical facilities serving Estes Park.

NONE

1996-05-01T23:59:59.000Z

65

High reliability low jitter 80 kV pulse generator  

Science Journals Connector (OSTI)

Switching can be considered to be the essence of pulsed power. Time accurate switch/trigger systems with low inductance are useful in many applications. This article describes a unique switch geometry coupled with a low-inductance capacitive energy store. The system provides a fast-rising high voltage pulse into a low impedance load. It can be challenging to generate high voltage (more than 50 kilovolts) into impedances less than 10???, from a low voltage control signal with a fast rise time and high temporal accuracy. The required power amplification is large, and is usually accomplished with multiple stages. The multiple stages can adversely affect the temporal accuracy and the reliability of the system. In the present application, a highly reliable and low jitter trigger generator was required for the Z pulsed-power facility [M.?E. Savage, L.?F. Bennett, D.?E. Bliss, W.?T. Clark, R.?S. Coats,J.?M. Elizondo, K.?R. LeChien, H.?C. Harjes, J.?M. Lehr, J.?E. Maenchen, D.?H. McDaniel, M.?F. Pasik, T.?D. Pointon, A.?C. Owen, D.?B. Seidel, D.?L. Smith, B.?S. Stoltzfus, K.?W. Struve, W.?A. Stygar, L.?K. Warne, and J.?R. Woodworth, 2007 IEEE Pulsed Power Conference, Albuquerque, NM (IEEE, Piscataway, NJ, 2007), p. 979]. The large investment in each Z experiment demands low prefire probability and low jitter simultaneously. The system described here is based on a 100 kV DC-charged high-pressure spark gap, triggered with an ultraviolet laser. The system uses a single optical path for simultaneously triggering two parallel switches, allowing lower inductance and electrode erosion with a simple optical system. Performance of the system includes 6 ns output rise time into 5.6???, 550 ps one-sigma jitter measured from the 5 V trigger to the high voltage output, and misfire probability less than 10-4. The design of the system and some key measurements will be shown in the paper. We will discuss the design goals related to high reliability and low jitter. While reliability is usually important, and is coupled with jitter, reliability is seldom given more than a qualitative analysis (if any at all). We will show how reliability of the system was calculated, and results of a jitter-reliability tradeoff study. We will describe the behavior of sulfur hexafluoride as the insulating gas in the mildly nonuniform field geometry at pressures of 300 to 500 kPa. We will show the resistance of the arc channels, and show the performance comparisons with normal two-channel operation, and single channel operation.

M. E. Savage and B. S. Stoltzfus

2009-08-27T23:59:59.000Z

66

Evaluation of first 10-kV optical ETO thyristor operating without any low-voltage control bias  

E-Print Network [OSTI]

unlike any existing ETO (or even IGCT/MTO/GTO devices) is reported at 10 kV using the Silvaco TCAD suite

Mazumder, Sudip K.

67

220 kV SSSC device for power flow control (Smart Grid Project) | Open  

Open Energy Info (EERE)

kV SSSC device for power flow control (Smart Grid Project) kV SSSC device for power flow control (Smart Grid Project) Jump to: navigation, search Project Name 220 kV SSSC device for power flow control Country Spain Headquarters Location Catalonia, Spain Coordinates 41.59116°, 1.520862° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":41.59116,"lon":1.520862,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

68

EIS-0450: TransWest Express 600 kV Direct Current Transmission Project in  

Broader source: Energy.gov (indexed) [DOE]

0: TransWest Express 600 kV Direct Current Transmission 0: TransWest Express 600 kV Direct Current Transmission Project in Wyoming, Colorado, Utah, and Nevada EIS-0450: TransWest Express 600 kV Direct Current Transmission Project in Wyoming, Colorado, Utah, and Nevada Summary This EIS, being prepared jointly by DOE's Western Area Power Administration and the Department of the Interior's Bureau of Land Management (Wyoming State Office), evaluates the environmental impacts of granting a right-of-way for the TransWest Express 600-kilovolt Direct Current Transmission Project and amending a land use plan. The project consists of an overhead transmission line that would extend approximately 725 miles from south-central Wyoming, through Colorado and Utah. Western proposes to be a joint owner of the project. Public Comment Opportunities

69

Microsoft Word - CX-Alvey 500 kV Fencing_WEB.doc  

Broader source: Energy.gov (indexed) [DOE]

3, 2010 3, 2010 REPLY TO ATTN OF: KEPR-4 SUBJECT: Environmental Clearance Memorandum Hamid Habibi Project Manager - TESF-CSB Proposed Action: Replace existing posts and fencing around Alvey Substation 500-kV switch yard. PP&A Project No.: 1 632 Budget Information: Work Order: 00250208 Task: 3 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.11 Installation of fencing, including that for border marking that will not adversely affect wildlife movements or surface water flow. Location: The proposed project is located in Lane County, Oregon at the Bonneville Power Administration (BPA) Alvey substation around the 500-kV switch yard. Proposed by: BPA Description of the Proposed Action: The project involves replacement of the existing fence and fence posts for the 500-kV yard at the

70

Field Demonstration of a 24-kV Superconducting Cable at Detroit Edison  

SciTech Connect (OSTI)

Customer acceptance of high temperature superconducting (HTS) cable technology requires a substantial field demonstration illustrating both the system's technical capabilities and its suitability for installation and operation within the utility environment. In this project, the world's first underground installation of an HTS cable using existing ductwork, a 120 meter demonstration cable circuit was designed and installed between the 24 kV bus distribution bus and a 120 kV-24 kV transformer at Detroit Edison's Frisbie substation. The system incorporated cables, accessories, a refrigeration system, and control instrumentation. Although the system was never put in operation because of problems with leaks in the cryostat, the project significantly advanced the state-of-the-art in the design and implementation of Warm Dielectric cable systems in substation applications. Lessons learned in this project are already being incorporated in several ongoing demonstration projects.

Kelley, Nathan; Corsaro, Pietro

2004-12-01T23:59:59.000Z

71

0.4 kV remote control (Smart Grid Project) | Open Energy Information  

Open Energy Info (EERE)

4 kV remote control (Smart Grid Project) 4 kV remote control (Smart Grid Project) Jump to: navigation, search Project Name 0.4 kV remote control Country Denmark Coordinates 56.26392°, 9.501785° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":56.26392,"lon":9.501785,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

72

EIS-0107: Mead-Phoenix +500-kV Direct Current Transmission Line  

Broader source: Energy.gov [DOE]

The U.S. Department of Energy’s Western Area Power Administration (WAPA) prepared this statement to analyze the potential environmental and socioeconomic impacts arising from WAPA and regional project sponsors’ proposal to construct a 500 kilovolt (kV) alternating current (AC) transmission line with the capability to be upgraded later to 500kV direct current (DC), connecting the Westwing Substation, located north of Phoenix, Arizona, with a new McCullough II Substation, located approximately 14 miles west of Boulder City, Nevada. This statement modifies a previously prepared federal statement from which the participants' election to proceed had not occurred at the time this statement was prepared.

73

Consideration of 34. 5 KV as an in-plant voltage for a large industrial user  

SciTech Connect (OSTI)

Traditionally, the in-plant distribution voltage for a large refinery or petrochemical complex has been 13.8 kV. Selection of this voltage level was dictated primarily by economic factors, simply because in most cases the magnitude of the loads or the lengths of the feeders did not produce sufficient savings to compensate for the costlier higher voltage switchgear. This paper presents some engineering and cost considerations for distribution at 34.5 kV and attempts to show that this voltage level is both economically and technically feasible for large electrical systems.

Niculescu, T.D.; Regan, R.R.

1983-09-01T23:59:59.000Z

74

Recreation of Neuronal Kv1 Channel Oligomers by Expression in Mammalian Cells Using Semliki Forest Virus  

Science Journals Connector (OSTI)

The multiple roles of voltage-sensitive K+ channels (Kv1 subfamily) in brain are served by subtypes containing pore-forming ? (1.1?1.6) and auxiliary ? subunits, usually in an (?)4(?)4 stoichiometry. To facilitate structure/activity analysis, combinations ...

Oleg Shamotienko; Sobia Akhtar; Christina Sidera; Frédéric A. Meunier; Barbara Ink; Malcolm Weir; J. Oliver Dolly

1999-12-01T23:59:59.000Z

75

Analysis on heat loss characteristics of a 10 kV HTS power substation  

Science Journals Connector (OSTI)

Abstract A 10 kV High Temperature Superconducting power substation (10 kV HTS substation), supported by Chinese State 863 projects, was developed and has been running to supply power for several factories for more than two years at an industrial park of Baiyin, Gansu province in Northwest China. The system of the 10 kV HTS substation compositions, including a HTS cable, a HTS transformer, a SFCL, and a SMES, are introduced. The SMES works at liquid helium temperature and the other three apparatus operates under liquid nitrogen condition. There are mainly four types of heat losses existing in each HTS apparatus of the 10 kV HTS substation, including AC loss, Joule heat loss, conductive heat, and leak-in heat from cryostat. A small quantity of AC loss still exists due to the harmonic component of the current when it carries DC for HTS apparatus. The principle and basis for analysis of the heat losses are introduced and the total heat loss of each apparatus are calculated or estimated, which agree well with the test result. The analysis and result presented are of importance for the design of the refrigeration system.

Yuping Teng; Shaotao Dai; Naihao Song; Jingye Zhang; Zhiyuan Gao; Zhiqin Zhu; Weiwei Zhou; Zhourong Wei; Liangzhen Lin; Liye Xiao

2014-01-01T23:59:59.000Z

76

Special design and testing aspects of the 345 kV East Fishkill substation  

SciTech Connect (OSTI)

The installation of two 135 MVAR capacitor banks in the 345 kV East Fishkill substation required special design of the grounding system, installation of reactors in series with the capacitor banks, closing resistors in the circuit breakers and special shielding of control cables. This paper describes the design of the substation and the tests performed before commissioning the capacitor banks.

Fogarty, R.P.; Halleran, T.M.; Laskowski, L.M.; Mark, D.A. (Consolidated Edison Co. of New York, Inc., New York, NY (United States))

1992-10-01T23:59:59.000Z

77

A charge-pump 60kV modulator for the ISOLDE target extraction voltage  

E-Print Network [OSTI]

The ISOLDE facility at CERN provides radioactive ion beams to a number of experimental stations. These ions are produced by a metal target, floating at 60 kV, which is impacted by a 1.4 GeV high intensity proton beam. The ions are then accelerated by a grounded extraction electrode to 60 keV, before transport to the experimental area. During proton beam impact extremely high ionisation of the volume around the target gives rise to significant leakage current which results in loss of charge on the effective target capacitance of approximately 6 nF. If short life-time isotopes are to be studied, the 60 kV must be re-established within a maximum of 10 ms. Recharging the target capacitance to 60 kV and to the required stability of better than 10-4 precludes a direct charging system and an alternative method of re-establishing the 60 kV is used. The present system [1], in operation since 1991, employs a resonant circuit which is triggered 35 µs prior to beam impact. This circuit transfers the charge on the effec...

Barlow, R A; Fowler, A; Gaudillet, H; Gharsa, T; Schipper, J

2015-01-01T23:59:59.000Z

78

Plasma Immersion Ion Implantation with a 4kV/10kHz Compact High Voltage Pulser  

SciTech Connect (OSTI)

Development of a 4 kV/10 kHz Compact High Voltage Pulser and its application to nitrogen plasma immersion ion implantation (PIII) of different materials as Si, Al alloys, SS304 stainless steel and Ti alloys are discussed. Low voltage (1-5 kV) pulses at high frequencies (up to 20 kHz for 2 kV) were obtained with maximum power delivered at 5 kV, 7 kHz. These conditions were not sufficient to reach temperatures above 200 deg. C in the samples because of short duration of the pulses. However, very shallow implantations of nitrogen in Si, Al5052, SS304 were observed by Auger electron spectroscopy and improved corrosion resistance was obtained for Al5052 when it was treated by nitrogen PIII at 2.5 kV, 5{mu}s and 5 kHz pulses.

Ueda, M.; Oliveira, R. M.; Rossi, J. O. [Associated Laboratory of Plasma, National Institute for Space Research, Av. dos Astronautas 1758, Sao Jose dos Campos, Sao Paulo (Brazil); Reuther, H. [Institute of Ion Beam Physics and Materials Research, Rossendorf, Dresden (Germany); Silva, G. [Associated Laboratory of Plasma, National Institute for Space Research, Av. dos Astronautas 1758, Sao Jose dos Campos, Sao Paulo (Brazil); Department of Aeronautics and Mechanics, Technological Institute of Aeronautics, Sao Jose dos Campos, Sao Paulo (Brazil)

2006-11-13T23:59:59.000Z

79

Notification of Planned 230kV Outage at Potomac River Generating Station |  

Broader source: Energy.gov (indexed) [DOE]

In accordance with DOE Order No. 202-05-03 Pepco is In accordance with DOE Order No. 202-05-03 Pepco is required to provide notification of any and all 230kV planned outages at Potomac River Generating Station. On Tuesday February 20, 2007 Potomac Electric Power Company (Pepco) will be taking a planned outage on the 23106 high voltage circuit between the Palmer's Corner Substation and the Potomac River Generating Station. Notification of Planned 230kV Outage at Potomac River Generating Station More Documents & Publications Re: Potomac River Generating Station Department of Energy Case No. EO-05-01: Advanced Notice of Power Outages. Special Environmental Analysis For Actions Taken under U.S. Department of Energy Emergency Orders Regarding Operation of the Potomac River Generating Station in Alexandria, Virginia

80

EIS-0365: Imperial-Mexicali 230-kV Transmission Lines  

Broader source: Energy.gov [DOE]

On February 27, 2001, Baja California Power, Inc. (hereafter referred to as Intergen), InterGen Aztec Energy, V.B.V., filed an application with DOE, Office of Fossil Energy, for a Presidential permit that would allow construction and connection of a double-circuit, 230-kV transmission line extending from the Imperial Valley Substation in California for a distance of about 6 mi (10 km) to a point west of Calexico at the U.S.-Mexico border.

Note: This page contains sample records for the topic "kv rating mva" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

ETM (Distribution Network Automation on 10 kV cable line stations) (Smart  

Open Energy Info (EERE)

ETM (Distribution Network Automation on 10 kV cable line stations) (Smart ETM (Distribution Network Automation on 10 kV cable line stations) (Smart Grid Project) Jump to: navigation, search Project Name ETM (Distribution Network Automation on 10 kV cable line stations) Country Hungary Headquarters Location Budapest, Hungary Coordinates 47.498405°, 19.040758° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":47.498405,"lon":19.040758,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

82

KvH Projekt GmbH Co KG | Open Energy Information  

Open Energy Info (EERE)

KvH Projekt GmbH Co KG KvH Projekt GmbH Co KG Jump to: navigation, search Name KvH Projekt GmbH & Co KG Place Hamburg, Germany Zip D-20259 Sector Biomass, Solar, Wind energy Product Project developer in wind, solar, biomass and smart architecture. Coordinates 53.553345°, 9.992455° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":53.553345,"lon":9.992455,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

83

Grand Coulee - Bell 500-kV Transmission Line Project, Draft Environmental Impact Statement  

SciTech Connect (OSTI)

BPA is proposing to construct a 500-kilovolt (kV) transmission line that would extend approximately 84 miles between the Grand Coulee 500-kV Switchyard, near Grand Coulee Dam, and the Bell Substation, in Mead just north of Spokane. The new line would cross portions of Douglas, Grant, Lincoln, and Spokane counties. In addition to the transmission line, new equipment would be installed at the substations at each end of the new line and at other facilities. The proposed action would remove an existing 115-kV transmission line and replace it with the new 500-kV line on existing right-of-way for most of its length. Additional right-of-way would be needed in the first 3.5 miles out of the Grand Coulee Switchyard to connect to the existing 115-kV right-of-way. Since the mid-1990s, the transmission path west of Spokane, called the West of Hatwai transmission pathway, has grown increasingly constrained. To date, BPA has been able to manage operation of the path through available operating practices, and customer needed have been met while maintaining the reliability of the path. however, in early 2001, operations showed that the amount of electricity that needs to flow from east to west along this path creates severe transmission congestion. Under these conditions, the system is at risk of overloads and violation of industry safety and reliability standards. The problem is particularly acute in the spring and summer months because of the large amount of power generated by dams east of the path. Large amounts of water cannot be spilled during that time in order for BPA to fulfill its obligation to protect threatened and endangered fish. The amount of power that needs to move through this area during these months at times could exceed the carrying capacity of the existing transmission lines. In additional capacity is not added, BPA will run a significant risk that it will not be able to continue to meet its contractual obligations to deliver power and maintain reliability standards that minimize risks to public safety and to equipment. BPA is considering two construction alternatives, the Agency Proposed Action and the Alternative Action. The Alternative Action would include all the components of the Preferred Action except a double-circuit line would be constructed in the Spokane area between a point about 2 miles west of the Spokane River and Bell Substation, a distance of about 9 miles. BPA is also considering the No Action Alternative.

N /A

2002-08-09T23:59:59.000Z

84

The results of systems tests of the 500 kV busbar controllable shunting reactor in the Tavricheskaya substation  

Science Journals Connector (OSTI)

The results of systems tests of the 500 kV busbar magnetization-controllable shunting reactor (CSR), set up in the Tavricheskaya substation, including measurements of the quality of the...

S. I. Gusev; V. N. Karpov; A. N. Kiselev; V. I. Kochkin

2009-09-01T23:59:59.000Z

85

30 kV coaxial vacuum-tight feedthrough for operation at cryogenic temperatures  

E-Print Network [OSTI]

In this paper we describe the technology of building a vacuum-tight high voltage feedthrough which is able to operate at voltages up to 30 kV. The feedthrough has a coaxial structure with a grounded sheath which makes it capable to lead high voltage potentials into cryogenic liquids, without risk of surface discharges in the gas phase above the liquid level. The feedthrough is designed to be used in ionization detectors, based on liquefied noble gases, such as Argon or Xenon.

I. Kreslo; I. Badhrees; S. Delaquis; A. Ereditato; S. Janos; M. Messina; U. Moser; B. Rossi; M. Zeller

2010-11-05T23:59:59.000Z

86

Proposal for the award of a contract for the design, supply, installation and commissioning of a 66 kV electrical substation  

E-Print Network [OSTI]

Proposal for the award of a contract for the design, supply, installation and commissioning of a 66 kV electrical substation

2012-01-01T23:59:59.000Z

87

DOE/EA-1470: Environmental Assessment Harry Allen-Mead 500 kV Transmission Line Project Environmental Assessment  

Broader source: Energy.gov (indexed) [DOE]

the the Interior Bureau of Land Management Las Vegas Field Office Las Vegas, Nevada March 2004 Interstate Intertie Centennial Plan Environmental Assessment Harry Allen - Mead 500kV Transmission Line DOE/EA-1470 Harry Allen-Mead 500kV Transmission Line Project Harry Allen-Mead 500kV Transmission Line Environmental Assessment 1 Chapter 1 Purpose and Need 1.1 Introduction The construction of new transmission and distribution facilities is required throughout the western United States to meet the increasing demand for power as more people move to many of the fastest growing communities. According to Executive Order 13212 dated May 18, 2001, "The increased production and transmission of energy in a safe and environmentally sound manner is essential to the well-being of the American people...agencies shall take appropriate actions, to the extent

88

Notification of Planned 230kV Outage at Potomac River Generating Station  

Broader source: Energy.gov (indexed) [DOE]

Sent: Wednesday, May 16, 2007 4:49 PM To: #DOE_Notification@pepco.com Subject: Notification of Planned 230kV Outage at Potomac River Generating Station To Whom It May Concern: This morning Pepco and PJM observed that the generation at the Potomac River Generating Station was having difficulty matching the station generation requirement to the Potomac River area load. Mirant has also informed Pepco and PJM that several generating units were experiencing equipment problems which required them to reduce unit and total plant output. Based on these observations and information received from Mirant, Pepco has elected to cease the current work activities underway on xxxxx high voltage circuit and we will be placing this transmission line back in service this afternoon.

89

A frequency domain model for 3 kV dc traction dc-side resonance identification  

SciTech Connect (OSTI)

Frequency-dependent effects in railway traction power systems arise from the impedance of substation and locomotive line filters and the traction line. Harmonic noise from traction drives and substations can excite resonances and produce overcurrent or overvoltage conditions at critical points in the network. In this paper, the harmonic feeding impedances of a 3 kV DC traction system seen from the rectifier substation, locomotive drive converter and pantograph terminals are presented. Several substation and locomotive filters are considered with a frequency-dependent traction line. Resonances attributed to the substation filter, locomotive filter and traction line are separate and distinct, the line introducing poles and zeros in the audio frequency (AF) range which vary in frequency and magnitude with locomotive position.

Hill, R.J. [Univ. of Bath (United Kingdom). School of Electronic and Electrical Engineering] [Univ. of Bath (United Kingdom). School of Electronic and Electrical Engineering; Fracchia, M.; Pozzobon, P.; Sciutto, G. [Univ. degli Studi di Genova (Italy). Dipt. di Ingegneria Elettrica] [Univ. degli Studi di Genova (Italy). Dipt. di Ingegneria Elettrica

1995-08-01T23:59:59.000Z

90

AC and lightning performance of fiberglass crossarms aged in 115 kV transmission line  

SciTech Connect (OSTI)

This paper presents the results of an investigation of the electrical performance of 115 kV transmission line fiberglass cross-arm used by Mississippi Power and Light Company. A transmission line fiberglass crossarm removed from service and companion cross-arms outdoors but not in service were examined. The evaluation of electrical performance was based on flashover voltage value at AC voltage and standard lightning impulses as well as under dry and wet conditions. The tests were performed in the Mississippi State University High Voltage Laboratory. The obtained flashover voltages show no large differences in electrical strength of fiberglass crossarms removed from service and those stored outdoors. The Added CFO voltage by fiberglass crossarm to the porcelain suspension insulators is presented versus the length of the fiberglass crossarm for dry and wet conditions.

Grzybowski, S. (Mississippi State Univ., Mississippi State, MS (United States). Dept. of Electrical and Computer Engineering); Jenkins, E.B. (Entergy, New Orleans, LA (United States). Generation and Transmission Group)

1993-10-01T23:59:59.000Z

91

Simulation of ion beam transport through the 400 Kv ion implanter at Michigan Ion Beam Laboratory  

SciTech Connect (OSTI)

The Michigan Ion Beam Laboratory houses a 400 kV ion implanter. An application that simulates the ion beam trajectories through the implanter from the ion source to the target was developed using the SIMION Registered-Sign code. The goals were to have a tool to develop an intuitive understanding of abstract physics phenomena and diagnose ion trajectories. Using this application, new implanter users of different fields in science quickly understand how the machine works and quickly learn to operate it. In this article we describe the implanter simulation application and compare the parameters of the implanter components obtained from the simulations with the measured ones. The overall agreement between the simulated and measured values of magnetic fields and electric potentials is {approx}10%.

Naab, F. U.; Toader, O. F.; Was, G. S. [Department of Engineering and Radiological Sciences, University of Michigan, 2355 Bonisteel Boulevard, Ann Arbor, MI 48109-2104 (United States)

2013-04-19T23:59:59.000Z

92

Weld-Windsor 115-kV Transmission Line Project, Weld County, Colorado  

SciTech Connect (OSTI)

The Western Area Power Administration is proposing to rebuild a 3.0 mile segment of the existing Flatiron-Weld 115-kV transmission line in Weld County. The line would be reconductored with new conductor on new wood pole double circuit structures. The new structures would support a double circuit transmission line configuration. The first circuit would be owned by Western and the second by Public Service Company of Colorado (PSCO). Alternatives considered included no action, constructing PSCO`s circuit on new right-of-way, and reconductoring Western`s existing line on the same structures. The proposed action was selected because it provided an opportunity to share structures with PSCO and, overall, would minimize costs and environmental impacts. The environmental assessment identifies minor effects on existing natural or human resources and minor benefits for agricultural operations.

NONE

1996-05-01T23:59:59.000Z

93

Final environmental assessment: Los Reales 115 kV transmission line alternative routes  

SciTech Connect (OSTI)

The Central Arizona Project (CAP) was authorized as a part of the Colorado River Basin Project Act (Public Law 90-537) on September 30, 1968. The primary purpose of the CAP is to furnish water for agricultural, municipal, and industrial uses in central and southern Arizona, and western New Mexico. Due to its magnitude, the CAP is divided into several major features serving separate but interrelated functions. The Tucson Aqueduct Phase B pumping plants were designed and constructed to operate on a looped power system. The entire looped power system, including two switching stations and connecting 115-kv transmission lines, was identified in the FEIS and approved for construction in the Secretary of Interior's Record of Decision dated September 24, 1985. The loop begins in the vicinity of the Twin Peaks Pumping Plant -- the northernmost Phase B pumping station, at the Rattlesnake Switching Station. All of the looped power system has been constructed with the exception of the switching station and portion of transmission line proposed to be constructed in this project. Without construction of this final portion of the looped power system, the Phase B pumping plants will not be able to operate normally without negatively affecting nearby power sources. The CAP will also not be able to provide the reliability necessary for municipal water systems dependent upon CAP water. The purpose of this EA is to describe impacts that would result from relocating the Los Reales 115-kV transmission line, and possibly the switching station, originally identified in the FEIS. It should be mentioned the Department of Energy will complete a separate NEPA review.

Not Available

1989-10-01T23:59:59.000Z

94

detonation rate  

Science Journals Connector (OSTI)

detonation rate, detonation velocity, velocity of detonation, V.O.D., detonating velocity, rate of detonation, detonating rate ? Detonationsgeschwindigkeit f

2014-08-01T23:59:59.000Z

95

A way to higher resolution: spherical-aberration correction in a 200 kV transmission electron microscope  

Science Journals Connector (OSTI)

......micrographs, ultramicroscopy 15: 151-172. rical pole-piece dimensions. The 200 kV spherical-aberra- 8 Thust A, Overwijk M H F, coene w M J. and Lentzen M (1996) tion-COrreCted microscope avoids the radiation damage Numerical correction of......

Knut Urban; Bernd Kabius; Max Haider; Harald Rose

1999-01-01T23:59:59.000Z

96

Study on Tubular Busbar Corona Design Optimization of ±660kV HVDC Converter Substation in Qingdao  

Science Journals Connector (OSTI)

The HVDC busbar corona characteristic is the main factor taken into account for choosing busbar of HVDC converter substation. By establishing the calculation models of electric field strength along the busbar surface, ground total electric field strength ... Keywords: ±660 kV HVDC, converter substation, corona characteristics, electromagnetic, tubular busbar optimization

Xu Mingming; Li Kejun; Tan Zhenyu; Niu Lin

2010-06-01T23:59:59.000Z

97

Development of 6.6kV/1.5kA-Class Superconducting Fault Current Limiter  

Science Journals Connector (OSTI)

The authors have developed and tested a 6.6kV/l.5kA-class superconducting fault current limiter, wound with an AC superconducting wire having ... up to 6.6kV were applied to the limiter. The limiter was able to s...

Kenji Tasaki; Kazuyuki Turunaga; Daisuke Ito…

1992-01-01T23:59:59.000Z

98

BNL test electron beam ion source operation on a 100 kV platform ,,abstract...a...,b...  

E-Print Network [OSTI]

BNL test electron beam ion source operation on a 100 kV platform ,,abstract...a...,b... E. N. Beebe to build an electron beam ion source EBIS that will satisfy the requirements of the relativistic heavy ion program. Development studies continue to be carried out on the BNL test EBIS, a half-length full electron

99

A fiducial detection algorithm for real-time image guided IMRT based on simultaneous MV and kV imaging  

SciTech Connect (OSTI)

The advantage of highly conformal dose techniques such as 3DCRT and IMRT is limited by intrafraction organ motion. A new approach to gain near real-time 3D positions of internally implanted fiducial markers is to analyze simultaneous onboard kV beam and treatment MV beam images (from fluoroscopic or electronic portal image devices). Before we can use this real-time image guidance for clinical 3DCRT and IMRT treatments, four outstanding issues need to be addressed. (1) How will fiducial motion blur the image and hinder tracking fiducials? kV and MV images are acquired while the tumor is moving at various speeds. We find that a fiducial can be successfully detected at a maximum linear speed of 1.6 cm/s. (2) How does MV beam scattering affect kV imaging? We investigate this by varying MV field size and kV source to imager distance, and find that common treatment MV beams do not hinder fiducial detection in simultaneous kV images. (3) How can one detect fiducials on images from 3DCRT and IMRT treatment beams when the MV fields are modified by a multileaf collimator (MLC)? The presented analysis is capable of segmenting a MV field from the blocking MLC and detecting visible fiducials. This enables the calculation of nearly real-time 3D positions of markers during a real treatment. (4) Is the analysis fast enough to track fiducials in nearly real time? Multiple methods are adopted to predict marker positions and reduce search regions. The average detection time per frame for three markers in a 1024x768 image was reduced to 0.1 s or less. Solving these four issues paves the way to tracking moving fiducial markers throughout a 3DCRT or IMRT treatment. Altogether, these four studies demonstrate that our algorithm can track fiducials in real time, on degraded kV images (MV scatter), in rapidly moving tumors (fiducial blurring), and even provide useful information in the case when some fiducials are blocked from view by the MLC. This technique can provide a gating signal or be used for intra-fractional tumor tracking on a Linac equipped with a kV imaging system. Any motion exceeding a preset threshold can warn the therapist to suspend a treatment session and reposition the patient.

Mao Weihua; Riaz, Nadeem; Lee, Louis; Wiersma, Rodney; Xing Lei [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California 94305-5847 (United States)

2008-08-15T23:59:59.000Z

100

Rural community noise caused by 345/138 kV substation transformer  

Science Journals Connector (OSTI)

Residents 360 m (1200 ft) from a large (6 × 8 × 4.5 m high) 345/138 kV transformer installed in a new power substation in a rural setting complained of its noise emission especially at night. Octave band and 24?h A?weighted noise measurements were made. The 120?Hz sound level was found to be 90 to 105 dB at the transformer surface. Transformer noise emission did not vary significantly with transformer loading or time of day. The distant (360 m) noise level was from 40 to 47 dBA (N?30 to N?45) depending on intervening terrain and time of day. In calm summer air the annoying sound was found to be in the 125?Hz band at the residence beyond a vegitated rise and 250 to 500 Hz for a residence with line?of?sight contact over a shallow depression. The line?of?sight resident's complaint that the noise was greatest at night was corroborated by the 24?h measurement. That noise level was found to be typically 38 dBA from 11 a.m. to 7 p.m. and 45 dBA from 9 p.m. to 6 a.m. It is postulated that the depression accumulated cool air at night thus refracting the sound onto that site. Recommendations for a noise barrier wall was made to the power company operator.

Angelo J. Campanella

1981-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "kv rating mva" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

EMI (electromagnetic interference) potential of proposed 115KV line near B-691  

SciTech Connect (OSTI)

The Laser Operated Diamond Turning Machine (LODTM) is housed in Building 691. This facility contains electronic measurement and control systems which could be susceptible to interfering electromagnetic interference (EMI) generated by sources external to B-691. In particular, concern has been expressed that such harmful EMI signals could be produced by the proposed WAPA 115KV feeder line which would be routed approximately 30 feet from the East side of the facility. Also, there has been some concern expressed about the effects of the resulting electromagnetic (EM) fields on personnel in the proximity of the power line. Since it is necessary to measure the EM fields to ascertain if a hazard does indeed exist, and since we in ERD have been performing such field measurements for many years, we were contacted to determine the field levels from the line that might be expected inside and close to B-691. This report describes our approach, equipment and calibration procedures, analysis techniques used, results, and suggestions for future work in related areas. 9 refs., 41 figs.

Latorre, V.R.; Wythe, D.M.

1989-07-27T23:59:59.000Z

102

Draft Environmental Impact Statement for the Imperial-Mexicali 230-kV Transmission Lines  

Broader source: Energy.gov (indexed) [DOE]

Imperial-Mexicali Imperial-Mexicali DEIS 1-4 May 2004 FIGURE 1.1-1 Regional Setting for Imperial-Mexicali 230-kV Transmission Lines Introduction Imperial-Mexicali DEIS 1-5 May 2004 FIGURE 1.1-2 La Rosita Power Complex: Electrical Distribution 2-40 May 2004 Alternatives Imperial-Mexicali DEIS TABLE 2.5-1 Summary of Impacts for Proposed Action and Other Alternatives by Resource Area a For the proposed action, that is, the granting of one or both of the Presidential permits and ROWs, for most resource areas, the analysis was bounded by calculating impacts as if both lines had been allowed. This serves two purposes. First, it demonstrates the maximum possible impacts; second, it clearly presents the combined impacts of the agencies' preferred alternative, that is, permitting both facilities. The only exceptions to this methodology are in the areas of air, water, and human health. Impacts to air, water, and human

103

KvAP1ORQ MthK3LDC Kv12R9R Supplementary Figure S1: Detailed view of TPenA docked into the 3 bestfit  

E-Print Network [OSTI]

of K2P channel block shown in Figure 1. Piechotta et al. Supplementary Information C2 TEA C4 TButA C5 TPenA C6 THexA C7 THepA C8 TOctA #12;Piechotta et al. Supplementary Information Supplementary Figure been published previously; a Milacet al(2011) b Treptow& Klein (2010). KvAP1ORQKv12R9RMthK3LDCKcsA3FB6

Tucker, Stephen J.

104

University of Waterloo Department of Electrical and Computer Engineering  

E-Print Network [OSTI]

transmission line power flows, voltage magnitudes and phase angles in a power system [2], [3]. Hence oscillations [4]. A ± 320 MVA, 138 kV UPFC has been recently commissioned for the American Electric Power [5], [6], and another project involving a ± 200 MVA, 345 kV UPFC is just under way. The latter is being

Cañizares, Claudio A.

105

DOE/EIS-0365; Final Environmental Impact Statement for the Imperial-Mexicali 230-kV Transmission Lines  

Broader source: Energy.gov (indexed) [DOE]

1 1 FINAL ENVIRONMENTAL IMPACT STATEMENT FOR THE IMPERIAL-MEXICALI 230-kV TRANSMISSION LINES Volume 1: Main Text and Appendixes A-L U.S. Department of Energy Washington, DC U.S. Department of the Interior Bureau of Land Management El Centro, CA Cooperating Agency December 2004 Cover Sheet Imperial-Mexicali FEIS iii December 2004 COVER SHEET RESPONSIBLE FEDERAL AGENCY: U.S. Department of Energy, Office of Fossil Energy COOPERATING AGENCY: U.S. Department of the Interior, Bureau of Land Management TITLE: Final Environmental Impact Statement for the Imperial-Mexicali 230-kV Transmission Lines LOCATION: Imperial County, California CONTACT: For further information on this environmental impact statement (EIS) contact: Mrs. Ellen Russell Office of Electric Power Regulation Office of Fossil Energy, FE-27

106

EIS-0399: Final EIS for the Montana Alberta Tie Ltd. (MATL) 230-KV Transmission Line Comments/Response  

Broader source: Energy.gov (indexed) [DOE]

9 9 Final Environmental Impact Statement for the Montana Alberta Tie Ltd. (MATL) 230-kV Transmission Line VOLUME 2 COMMENT RESPONSE DOCUMENT September 2008 United States Department of Energy State of Montana Department of Environmental Quality COVER SHEET Responsible Agencies: U.S. Department of Energy (DOE) and Montana Department of Environmental Quality (DEQ) are co-lead agencies; the Bureau of Land Management (BLM), U.S. Department of the Interior, is a cooperating agency. Title: Final Environmental Impact Statement for the Montana Alberta Tie Ltd. (MATL) 230-kV Transmission Line (DOE/EIS-0399) Location: Cascade, Teton, Chouteau, Pondera, Toole, and Glacier counties, Montana. Contacts: For further information about this Final EIS, contact: Ellen Russell, Project Manager,

107

DOE/EA-1470: Environmental Assessment Harry Allen-Mead 500 kV Transmission Line Project Environmental Assessment  

Broader source: Energy.gov (indexed) [DOE]

4 4 DOE/EA-1470 DEPARTMENT OF ENERGY Western Area Power Administration Finding of No Significant Impact and Floodplain Statement of Findings Nevada Power Company's Harry Allen-Mead 500-kV Transmission Line Project Summary - Nevada Power Company (Nevada Power) proposes to build a 48- mile, 500-kilovolt (kV) transmission line between the Harry Allen Substation, northeast of Las Vegas Nevada, and the Mead Substation, southeast of Las Vegas (Proposed Action). The project would be part of the Interstate Intertie of the Centennial Plan. Of the 48 miles, 32 miles are within lands managed by the Bureau of Land Management (BLM), 8 miles are within lands managed by the US Bureau of Reclamation (USBR), and 4 miles are within lands managed by Western Area

108

Western Area Power Administration, Desert Southwest Region Parker-Gila 161-kV Transmission Line Maintenance, Cross Arm  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Parker-Gila 161-kV Transmission Line Maintenance, Cross Arm Parker-Gila 161-kV Transmission Line Maintenance, Cross Arm Replacements at Structure 0/7 - Continuation Sheet Special Conditions Biological Resources 1. To avoid impacts to nesting birds, project activities will be scheduled between August 1 and February 15, as feasible. Crews shall not cause injury or death to nesting birds, active nests, eggs, or nestlings. If evidence of a nesting bird is found in the project area, crews shall immediately stop work in that area until Western's Environmental Group has been contacted. 2. A qualified biologist will be present during all project activities and serve as the project's Biological Monitor. The Biological Monitor will be authorized by Western to temporarily halt construction activity if needed to prevent harm to desert tortoise. The Biological Monitor's

109

EIS-0505: Vantage to Pomona Heights 230 kV Transmission Line Project, Yakima, Grant, Benton and Kittitas Counties, Washington  

Broader source: Energy.gov [DOE]

The Bureau of Land Management is preparing, with DOE’s Bonneville Power Administration (BPA) as a cooperating agency, an EIS that evaluates the potential environmental impacts of a proposal to construct a 60- to 67-mile long 230-kV transmission line. BPA’s proposed action is to interconnect the transmission line to an existing BPA substation. Additional information is available at http://www.blm.gov/or/districts/spokane/plans/vph230/.

110

EIS-0025: Miles City-New Underwood 230-kV Electrical Transmission Line, Montana, North Dakota, and South Dakota  

Broader source: Energy.gov [DOE]

The U.S. Department of Energy’s Western Area Power Administration prepared this statement to assess the environmental and socioeconomic implications of its proposed action to construct a 3.28-mile, 230-kV transmission line between Miles City and Baker, Montana , Hettinger, North Dakota , and New Underwood , South Dakota , in Custer and Fallon Counties in Montana, Adams , Bowman , and Slope Counties in North Dakota and Meade, Pennington, and Perkins Counties in South Dakota.

111

Environmental Assessment of the Gering-Stegall 115-kV Transmission Line Consolidation Project, Scotts Bluff County, Nebraska  

SciTech Connect (OSTI)

The Department of Energy (DOE), Western Area Power Administration (Western) proposes to consolidate segments of two transmission lines near the Gering Substation in Gering, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska, within the city of Gering. Presently, there are three parallel 115-kilovolt (kV) transmission lines on separate rights-of-way (ROW) that terminate at the Gering Substation. The project would include dismantling the Archer-Gering wood-pole transmission line and rebuilding the remaining two lines on single-pole steel double circuit structures. The project would consolidate the Gering-Stegall North and Gering-Stegall South 115-kV transmission lines on to one ROW for a 1.33-mile segment between the Gering Substation and a point west of the Gering Landfill. All existing wood-pole H-frame structures would be removed, and the Gering-Stegall North and South ROWs abandoned. Western is responsible for the design, construction, operation, and maintenance of the line. Western prepared an environmental assessment (EA) that analyzed the potential environmental impacts of the proposed construction, operation, and maintenance of the 115-kV transmission line consolidation. Based on the analyses in the EA, the DOE finds that the proposed action is not a major Federal action significantly affecting the quality of the human environment, within the meaning of the National Environmental Policy Act of 1969 (NEPA).

NONE

1995-05-01T23:59:59.000Z

112

The Results of Tests of ASK-100-4UKhL4 Type Asynchronized Compensators at the Beskudnikovo 500 kV Substation  

Science Journals Connector (OSTI)

Two ASK-100-4UKhL4 100 Mvar asynchronized compensators were introduced into operation in the 500 kV Beskudnikovo substation in 2012. The results of systems tests...

L. G. Volodarskii; I. Ya. Dovganyuk; R. D. Mnev…

2014-01-01T23:59:59.000Z

113

DOE/EA-1354; Environmental Assessment for the Fort Collins 115kV Transmission Line Upgrade Project (12/2001)  

Broader source: Energy.gov (indexed) [DOE]

Western Area Power Administration Western Area Power Administration Fort Collins 115-kV Transmission Line Upgrade Project, Fort Collins, Colorado. AGENCY: Western Area Power Administration, DOE ACTION: Finding of no significant impact SUMMARY: The Department of Energy (DOE), Western Area Power Administration (Western) is the lead federal agency for a proposed project to upgrade the electric transmission system in the Fort Collins, Colorado area. Platte River Power Authority (Platte River) is proposing to add additional generation at its Rawhide Power Plant, to rebuild and upgrade segments of Western's existing Flatiron-Poudre and Poudre-Richard's Lake 115-kilovolt (kV) transmission lines, and to install additional 230 kV transmission to Platte River's existing electrical system. Western prepared an environmental assessment (EA) titled "Fort Collins 115kV Transmission

114

EIS-0005-FS: Bonneville Power Administration Proposed FY 1979 Program, Facility Location on Supplement, Southwest Oregon Area Service, Buckley-Summer Lake 500 kV Line, Supplemental  

Broader source: Energy.gov [DOE]

This Bonneville Power Administration document assesses the environmental impacts of constructing transmission facilities, which will coordinate with the Midpoint-Malin 500-kV line to be constructed by the Pacific Power and Light (PP&L) Company. The proposed action includes the construction of the 1.56-mile Buckley-Summer Lake 500-kV transmission line; the proposed Buckley Substation near Maupin, Oregon; and the proposed Summer Lake Substation near Silver Lake, Oregon.

115

Rate Schedules  

Broader source: Energy.gov [DOE]

One of the major responsibilities of Southeastern is to design, formulate, and justify rate schedules. Repayment studies prepared by the agency determine revenue requirements and appropriate rate...

116

Rates - WAPA-137 Rate Order  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

WAPA-137 Rate Order WAPA-137 Rate Order 2009 CRSP Management Center Customer Rates Second Step Presentation from the June 25, 2009, Customer Meeting Handout Materials from the June 25, 2009, Customer Meeting Customer Comment Letters ATEA CREDA Farmington ITCA AMPUA Rate Adjustment Information The second step of WAPA-137 SLCA/IP Firm Power, CRSP Transmission and Ancillary Services rate adjustment. FERC Approval of Rate Order No. WAPA-137 Notice Of Filing for Rate Order No. WAPA-137 Published Final FRN for Rate Order No. WAPA-137 Letter to Customers regarding the published Notice of Extension of Public Process for Rate Order No. WAPA-137 Published Extension of Public Process for Rate Order No. WAPA-137 FRN Follow-up Public Information and Comment Forum Flier WAPA-137 Customer Meetings and Rate Adjustment Schedule

117

DOE/EIS-0365; Final Environmental Impact Statement for the Imperial-Mexicali 230-kV Transmission Lines  

Broader source: Energy.gov (indexed) [DOE]

2 2 FINAL ENVIRONMENTAL IMPACT STATEMENT FOR THE IMPERIAL-MEXICALI 230-kV TRANSMISSION LINES Volume 2: Comment and Response Document U.S. Department of Energy Washington, DC U.S. Department of the Interior Bureau of Land Management El Centro, CA Cooperating Agency December 2004 Comment and Response Document Imperial-Mexicali FEIS iii December 2004 CONTENTS NOTATION .......................................................................................................................... v ENGLISH/METRIC AND METRIC/ENGLISH EQUIVALENTS..................................... ix 1 PUBLIC REVIEW OF THE DRAFT ENVIRONMENTAL IMPACT STATEMENT ................................................................................................................ 1-1 1.1 Overview of the Public Review Process

118

The results of systems tests of the 500 kV busbar controllable shunting reactor in the Tavricheskaya substation  

SciTech Connect (OSTI)

The results of systems tests of the 500 kV busbar magnetization-controllable shunting reactor (CSR), set up in the Tavricheskaya substation, including measurements of the quality of the electric power, the harmonic composition of the network currents of the reactor for different values of the reactive power consumed, the determination of the regulating characteristics of the reactor, the speed of response of the shunting reactor in the current and voltage stabilization modes, and also the operation of the reactor under dynamic conditions for different perturbations, are presented. The results obtained are analyzed.

Gusev, S. I. [JSC 'FSK EES' (Russian Federation); Karpov, V. N.; Kiselev, A. N.; Kochkin, V. I. [Scientific-Research Institute of Electric Power Engineering (VNIIE) - Branch of the JSC 'NTTs Elektroenergetiki', (Russian Federation)

2009-09-15T23:59:59.000Z

119

OPERATIONAL RESULTS OF THE SPALLATION NEUTRON SOURCE (SNS) POLYPHASE CONVERTER-MODULATOR FOR THE 140 KV KLYSTRON RF SYSTEMS  

SciTech Connect (OSTI)

This paper describes the first operational results of the 140 kV, 1 MW average, 11 MW peak, zero-voltage-switching, 20 kHz polyphase bridge, boost converter-modulator for klystron pulse application. The DC-DC converter derives the buss voltages from a standard 13.8 kV to 2100 Y substation cast-core transformer. Energy storage and filtering is provided by self-clearing metallized hazy polypropylene traction capacitors. Three ''H-Bridge'' Insulated Gate Bipolar Transistor (IGBT) switching networks are used to generate the polyphase 20 kHz transformer primary drive waveforms. The 20 kHz drive waveforms are chirped the appropriate duration to generate the desired klystron pulse width. Pulse-Width Modulation (PWM) of the individual 20 kHz pulses is utilized to provide regulated output waveforms with adaptive feedforward and feedback techniques. The boost transformer design utilizes amorphous nanocrystalline material that provides the required low core loss at design flux levels and switching frequencies. Resonant shunt peaking is used on the transformer secondary to boost output voltage and resonate transformer leakage inductance. With the appropriate transformer leakage inductance and peaking capacitance, zero-voltage-switching of the IGBT's is attained, minimizing switching losses. Reviews of these design parameters and an examination of the first operational results will be performed.

W.A. REASS; J.D. DOSS; ET AL

2001-06-01T23:59:59.000Z

120

Quench current degradation in superconducting coil for 6.6 kV/2 fault current limiter  

SciTech Connect (OSTI)

A 6.6 kV/2 kA class fault current limiter that consists of non-inductive superconducting windings was developed and tested. The limiter can deliver continuous power at 2 kArms and limit fault current of more than 20 kA to 4 kA in 6 kV. The limiter recovers to the superconducting state within a few seconds and can perform a fault current limiting operation in 60 seconds after the last limiting operation. After high-voltage operation, however, the quench current of the limiter dropped significantly. This quench current degradation is related to the coil bobbin strain due to helium pressure raised by large ohmic heating in quenching. The degradation is a fatal problem for a fault current limiter if the quench current falls below the operating current because the limiter cannot revert to the normal operation. High Young`s modulus bobbin is effective to remove the coil degradation. They have obtained a fault current limiter without any degradation after repeated limiting operations.

Tasaki, K.; Yazawa, T.; Yoneda, E.S.; Nomura, S.; Maeda, H. [Toshiba Corp., Kawasaki (Japan). Research and Development Center] [Toshiba Corp., Kawasaki (Japan). Research and Development Center; Ohkuma, T.; Nakade, M.; Hara, T. [Tokyo Electric Power Co., Yokohama (Japan). Power Engineering R and D Center] [Tokyo Electric Power Co., Yokohama (Japan). Power Engineering R and D Center

1996-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "kv rating mva" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Flatiron-Erie 115kV transmission line project, Larimer, Weld and Boulder Counties, Colorado. Draft environmental impact statement  

SciTech Connect (OSTI)

Western Area Power Administration (Western) proposes to uprate its existing 115-kV Flatiron-Erie transmission line. The line is located in Larimer, Weld and Boulder Counties, Colorado, and passes through the City of Longmont. The line connects Flatiron Substation and several of the substations supplying Longmont. It is a single circuit 115-kV line, 31.5 miles long, and was built in 1950-51 on a 75-foot wide right-of-way (ROW) using wood H-frame structures. Western proposes to build 27 new structures along the line, to replace or modify 45 of the existing structures and to remote 11 of them. Many of these additions and changes would involve structures that are approximately 5 to 15 feet taller than the existing ones. The existing conductors and ground wires would remain in place. The purpose of these actions would be to allow the power carrying capability of the line to be increased and to replace deteriorating/structural members. Western would be the sole participant in the proposed project. This report gives an analysis of the study area environment and the development of alternative routes. An assessment is presented of the impacts of the primary alternative routes. The environmental consequences of this project are addressed.

Not Available

1993-05-01T23:59:59.000Z

122

Rate schedule  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Firm Power Service Provided by Rate/Charges Firm Power Service Provided by Rate/Charges Rate/Charges Effective Through (or until superceded) Firm Sales (SLIP-F9) Composite Rate SLIP 29.62 mills/kWh 9/30/2015 Demand Charge SLIP $5.18/kW-month 9/30/2015 Energy Charge SLIP 12.19 mills/kWh 9/30/2015 Cost Recovery Charge (CRC) SLIP 0 mills/kWh 9/30/2015 Transmission Service Provided by Current Rates effective10/12 - 9/15 (or until superceded) Rate Schedule Effective Through Firm Point-to-Point Transmission (SP-PTP7) CRSP $1.14 per kW-month $13.69/kW-year $0.00156/kW-hour $0.04/kW-day $0.26/kW-week 10/1/2008-9/30/2015 Network Integration Transmission (SP-NW3) CRSP see rate schedule 10/1/2008-9/30/2015 Non-Firm Point-to-Point Transmission (SP-NFT6) CRSP see rate schedule 10/1/2008-9/30/2015 Ancillary Services Provided by Rate Rate Schedule

123

Federal Draft Environmental Impact Statement and State of Montana Supplemental Draft Environmental Impact Statement for the Montana Alberta Tie Ltd. (MATL) 230-kV Transmission Line  

Broader source: Energy.gov (indexed) [DOE]

S-1 S.1 Introduction This document is both a State of Montana Supplemental Draft Environmental Impact Statement (EIS) and a U.S. Department of Energy (DOE) Federal Draft EIS (referred to herein as the Draft EIS for both state and federal purposes) prepared for the United States portion of the proposed Montana Alberta Tie Ltd. (MATL) 230-kilovolt (kV) transmission line. MATL has proposed to construct an international 230-kV alternating current merchant (private) transmission line that would originate at an existing NorthWestern Energy (NWE) 230-kV switch yard at Great Falls, Montana, and extend north to a new substation to be constructed northeast of Lethbridge, Alberta, crossing the U.S.-Canada international border north of Cut Bank, Montana (proposed Project). Approximately

124

Improvements in the computation of balances and localization of commercial losses of electric energy in 0.38-kV networks  

SciTech Connect (OSTI)

An example of four 0.38-kV overhead distribution lines fed from a 10/0.4-kV transformer substation of the Grodno Electrical Networks (Belarus') and supplying electricity to a cottage area is used for analyzing energy balances and commercial losses in the networks. It is shown that the reliability of such analysis can be ensured by the use of modern software and electronic energy meters recording a retrospective of half-hourly intervals of active and reactive electric energy.

Vorotnitskii, V. Z.; Zaslonov, S. V.; Lysyuk, S. S. [Electric Power Research Institute (VNIIE) (Russian Federation)

2006-11-15T23:59:59.000Z

125

Design and Simulation of Novel Enhancement Mode 5–20 kV GaN Vertical Superjunction High Electron Mobility Transistors for Smart Grid Applications  

Science Journals Connector (OSTI)

We report on the design, simulations and optimization of a novel enhancement mode 5–20 kV GaN vertical superjunction (SJ) high electron mobility transistor (HEMT). We optimize the space charge in GaN pillars using GaN SJ p–n diode for the best trade-off between breakdown voltage (BV) and specific on-resistance (Ronsp), by varying the pillar dosage, length and width. The resulting GaN SJ field effect transistor (FET) structure is projected to have, for example, Ronsp of 4.2 m? cm2 with BV of 12.4 kV.

Zhongda Li; T. Paul Chow

2013-01-01T23:59:59.000Z

126

Characterization of the CEBAF 100 kV DC GaAs Photoelectron Gun Vacuum System  

SciTech Connect (OSTI)

A vacuum system with pressure in the low ultra-high vacuum (UHV) range is essential for long photocathode lifetimes in DC high voltage GaAs photoguns. A discrepancy between predicted and measured base pressure in the CEBAF photoguns motivated this study of outgassing rates of three 304 stainless steel chambers with different pretreatments and pump speed measurements of non-evaporable getter (NEG) pumps. Outgassing rates were measured using two independent techniques. Lower outgassing rates were achieved by electropolishing and vacuum firing the chamber. The second part of the paper describes NEG pump speed measurements as a function of pressure through the lower part of the UHV range. Measured NEG pump speed is high at pressures above 5×10^?11 Torr, but may decrease at lower pressures depending on the interpretation of the data. The final section investigates the pump speed of a locally produced NEG coating applied to the vacuum chamber walls. These studies represent the first detailed vacuum measurements of CEBAF photogun vacuum chambers.

M.L. Stutzman; P. Adderley; J. Brittian; J. Clark; J. Grames; J. Hansknecht; G.R. Myneni; M. Poelker

2007-05-01T23:59:59.000Z

127

Type A Accident Investigation Report on the June 25, 1997, Contractor Inspector Fatality on the Satsop-Aberdeen #2 & #3 230 kV Line  

Broader source: Energy.gov [DOE]

On June 27, 1997, I established a Type-A Accident Investigation Board to investigate the June 25, 1997 fatal contractor accident which occurred on BPA?s Satsop-Aberdeen #2 and #3 230-kV transmission lines right-of-way.

128

Increasing the reliability of the shutdown of 500 - 750-kV overhead lines equipped with shunt reactors in an unsuccessful three-phase automatic repeated closure cycle  

SciTech Connect (OSTI)

The reasons for circuit-breaker failures during repeated disconnection of 500 - 750 kV overhead lines with shunt reactors in a cycle of unsuccessful three-phase automatic reconnection (TARC) are analyzed. Recommendations are made for increasing the operating reliability of power transmission lines with shunt reactors when there is unsuccessful reconnection.

Kuz'micheva, K. I.; Merzlyakov, A. S.; Fokin, G. G. [JSC 'R and D Center at Federal Grid Company of the United Power System' (Russian Federation)

2013-05-15T23:59:59.000Z

129

Seasonal Patterns of Melatonin, Cortisol, and Progesterone Secretion in Female Lambs Raised Beneath a 500-kV Transmission Line.  

SciTech Connect (OSTI)

Although several kinds of biological effects of electric and magnetic fields have been reported from laboratory studies, few have been independently replicated. When this study was being planned, the suppression of nighttime melatonin in rodents was thought to represent one of the strongest known effects of these fields. The effect had been replicated by a single laboratory for 60-Hz electric fields, and by multiple laboratories for d-c magnetic fields. The primary objective of this study was to determine whether the effect of electric and magnetic fields on melatonin would also occur in sheep exposed to a high voltage transmission line. The specific hypothesis tested by this experiment was as follows: The electrical environment produced by a 60-Hz, 500-kV transmission line causes a depression in nocturnal melatonin in chronically exposed female lambs. This may mimic effects of pinealectomy or constant long-day photoperiods, thus delaying the onset of reproductive cycles. Results of the study do not provide evidence to support the hypothesis. Melatonin concentrations in the sheep exposed to the transmission line showed the normal pattern of low daytime and high nighttime serum levels. As compared to the control group, there were no statistically significant group differences in the mean amplitude, phase, or duration of the nighttime melatonin elevation.

Lee, Jack M.

1992-06-01T23:59:59.000Z

130

(DOE/EIS-0285/SA 118): Supplement Analysis for the Transmission System Vegetation Management Program EIS, Holcomb-Naselle 115kV)  

Broader source: Energy.gov (indexed) [DOE]

7, 2003 7, 2003 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-SA 118, Holcomb - Naselle 115 kV. James A. Jellison - TFO/Olympia Proposed Action: Vegetation Management along the Holcomb Naselle 115kV transmission line corridor from structure 1/1 through structure 21/10. Right of way width averages 100 feet. Location: The project area is located in Pacific County, Washington. Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes to remove unwanted vegetation along the right-of- way, access roads and around tower structures along the subject transmission line corridor. Approximately 21 miles of right-of-way will be treated using selective and non-selective

131

DOE/EA-1354; Environmental Assessment for the Fort Collins 115kV Transmission Line Upgrade Project (12/2001)  

Broader source: Energy.gov (indexed) [DOE]

ENVIRONMENTAL ASSESSMENT ENVIRONMENTAL ASSESSMENT FOR THE FORT COLLINS 115kV TRANSMISSION LINE UPGRADE PROJECT Prepared for: Platte River Power Authority and U.S. Department of Energy Western Area Power Administration DOE/EA 1354 September 2001 i TABLE OF CONTENTS SUMMARY ............................................................................................................... S-1 1.0 INTRODUCTION ...............................................................................................1-1 1.1 DESCRIPTION OF PROPOSED PROJECT .................................................................. 1-1 1.3 PURPOSE OF ENVIRONMENTAL ASSESSMENT....................................................

132

Testing of a 50 kA, 50 kV current interrupter with I sup 2 t preheating and long recovery voltage  

SciTech Connect (OSTI)

The Confinement Physics Research Facility (CPRF) presently being constructed at Los Alamos in a next generation Reversed Field Pinch (RFP) plasma experiment. An inductive energy transfer system, employing a 50 kA, 50 kV dc current interrupter, is being utilized for initiating the plasma current. These performance requirements (50 kA, 50 kV) had yet to be realized in a reliable switching system, development of this current interrupter system was initiated. A switch test bay with a 50 kA battery bank has been built at Los Alamos to test the interrupter in conditions which will exist in the CPRF experiment. Many switch parameters were measured to provide information on the current interrupting characteristics and reliability. Some of these diagnostics include voltage, current, pre and post I{sup 2}t contact resistance, opening speed and position, arc voltage, and stem temperature. To determine any long term changes, all shots and data channels are computer indexed, and may be easily recalled for review. Extensive testing was performed on Siemens D-10 vacuum interrupter. Test parameter space included 55 kA, 40 kV (per bottle); di/dt of 2250 A/{mu}s, I{sup 2}t of 5 {times} 10{sup 9} amp{sup 2} sec; and 20 kV-200 msec RC recovery decay. Circuit parameters effect opening reliability. Circuit data and the associated testing results will be presented along with long term trends of switch performance under normal'' conditions. 12 figs.

Reass, W.A.; Boenig, H.J.; Melton, J.G. (Los Alamos National Lab., NM (USA))

1989-01-01T23:59:59.000Z

133

Microsoft Word - MVA - Table.docx  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Projects and Congressional Districts Projects and Congressional Districts Title Performer Congressional District A Sea Floor Gravity Survey of the Sleipner Field to Monitor CO 2 Migration SCRIPPS (Scripps Institute of Oceanography) CA53 Advanced Technologies for Monitoring CO 2 Saturation and Pore Pressure in Geologic Formations: Linking the Chemical and Physical Effects to Elastic and Transport Properties Stanford University CA14 Basic Science of Retention Issues, Risk Assessment & Measurement, Monitoring, & Verification for Geologic CO 2 Sequestration Montana State University MT01 Brookhaven National Laboratory - New Approach for Long-Term Monitoring of CO 2 Leaks from Geologic Sequestratation Brookhaven National Laboratory NY01 Combining Space Geodesy, Seismology, and Geochemistry for Monitoring,

134

CX-010683: Categorical Exclusion Determination | Department of...  

Broader source: Energy.gov (indexed) [DOE]

Categorical Exclusion Determination "Glen Canyon Substation Stage 09- 50MVA 23069KV Transformer addition CX(s) Applied: B4.11 Date: 07022013 Location(s): Arizona, Arizona...

135

Rates & Repayment  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Environmental Review-NEPA Financial Data Operations Planning & Projects Power Marketing Rates Rate Adjustments Transmission Ancillary Services Rates WAPA-137 Rate Order Environmental Review-NEPA Financial Data Operations Planning & Projects Power Marketing Rates Rate Adjustments Transmission Ancillary Services Rates WAPA-137 Rate Order Rates and Repayment Services Rates Current and Historical Rate Information Collbran Power Rates CRSP Power Rates CRSP Transmission System Rates CRSP Management Center interest rates Falcon-Amistad Power Rates Provo River Power Rates Rio Grande Power Rates Seedskadee Power Rates SLCA/IP Power Rates Rate Schedules & Supplemental Rate Information Current Rates for Firm Power, Firm & Non-firm Transmission Service, & Ancillary Services Current Transmission & Ancillary Services Rates Tariffs Components of the SLCA/IP Existing Firm Power Rate Cost Recovery Charge (CRC) Page MOA Concerning the Upper Colorado River Basin

136

Chlorite Dissolution Rates  

SciTech Connect (OSTI)

Spreadsheets provides measured chlorite rate data from 100 to 300C at elevated CO2. Spreadsheet includes derived rate equation.

Carroll, Susan

2013-07-01T23:59:59.000Z

137

Chlorite Dissolution Rates  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

Spreadsheets provides measured chlorite rate data from 100 to 300C at elevated CO2. Spreadsheet includes derived rate equation.

Carroll, Susan

138

Power Rate Cases (pbl/rates)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Choices (2003-06) Power Function Review (PFR) Firstgov Power Rate Cases BPA's wholesale power rates are set to recover its costs and repay the U.S. Treasury for the Federal...

139

Electric Power Annual 2011  

Gasoline and Diesel Fuel Update (EIA)

Capacity Capacity Conductor Characteristics Data Year Country NERC Region NERC Sub- region Type Operating (kV) Design (kV) Rating (MVa) Month Year From Terminal To Terminal Length (Miles) Type Pole Type Pole Material Size (MCM) Material Bundling Arrange- ment Present Ultimate Company Code Company Name Organizational Type Ownership (Percent) Project Name Level of Certainty Primary Driver 1 Primary Driver 2 2011 US TRE ERCOT AC 300-399 5 2018 DeCordova Benbrook 27 OH 44372 Delivery 100 00TPIT0004 Conceptual Reliability 2011 US TRE ERCOT AC 300-399 5 2018 Loma Alta Substation Rio Hondo Substation 35 OH 2409 BPUB 100 00TPITno07 Conceptual Reliability 2011 US TRE ERCOT AC 121-150 6 2014 Highway 32 Wimberley 4 OH 14626 PEC 100 05TPIT0065 Planned Reliability 2011 US TRE ERCOT AC 121-150 5 2018 Ennis Switch Ennis 6.32 OH 44372 Oncor Electric Delivery 100

140

NETL F 451.1-1/1 Categorical Exclusion (CX) Designation Form  

Broader source: Energy.gov (indexed) [DOE]

Waukesha Electric's activities Waukesha Electric's activities Energy Delivery Technologies Div 2010 David Szucs approx. July 2010 - January 2015 Waukeshaa, WI "Recovery Act - Fault Current Limiting Superconducting Transformer" Design and fabricate a prototype superconducting fault current limiting transformer (rated 28 MVA, 66kV/12kV service),whose operation will be demonstrated in a Southern California Edison switchyard. 07 02 2010 David Szucs Digitally signed by David Szucs DN: cn=David Szucs, o=NETL, ou=EDTD, email=szucs@netl.doe.gov, c=US Date: 2010.07.02 12:46:32 -04'00' 07 13 2010 Fred E. Pozzuto Digitally signed by Fred E. Pozzuto DN: cn=Fred E. Pozzuto, o=USDOE, ou=NETL-Office of Project Facilitation and Compliance, email=fred.pozzuto@netl.doe.gov, c=US Reason: I am approving this document

Note: This page contains sample records for the topic "kv rating mva" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

NETL F 451.1-1/1 Categorical Exclusion (CX) Designation Form  

Broader source: Energy.gov (indexed) [DOE]

44 44 Waukesha Electric System, Inc OE Southern Cal Edison activities Energy Delivery Technologies Div 2010 David Szucs approx. July 2010- January 2015 Irvine, CA "Recovery Act-Fault Current Limiting (FCL) Superconducting Transformer" Southern California Edison will install & operate a prototype FCL superconducting transformer rated 28 MVA, 66kV/12kV service, built by Waukesha Electric, in their MacArthur substation as a demonstration. 07 02 2010 David Szucs Digitally signed by David Szucs DN: cn=David Szucs, o=NETL, ou=EDTD, email=szucs@netl.doe.gov, c=US Date: 2010.07.02 13:16:07 -04'00' 07 16 2010 Fred E. Pozzuto Digitally signed by Fred E. Pozzuto DN: cn=Fred E. Pozzuto, o=USDOE, ou=NETL-Office of Project Facilitation and Compliance, email=fred.pozzuto@netl.doe.gov, c=US

142

Curecanti-Blue Mesa-Salida 115-kV transmission lines access roads rehabilitation, maintenance, and construction project. Environmental Assessment  

SciTech Connect (OSTI)

Western Area Power Administration (Western) is a power marketing agency of the US Department of Energy, with jurisdiction in 15 western states. The Salt Lake City Area (SLCA) of Western performs the agency`s mission in parts of Colorado, New Mexico, Texas, Utah, Arizona, Wyoming, and Nevada. As part of its mission, Western owns, operates, and maintains a system of transmission lines for transmitting bulk electrical energy from points of generation to and between delivery points. Part of that system in southwestern Colorado includes the Blue Mesa-Curecanti and Blue Mesa-Salida 115-kV transmission lines. Western proposes to conduct maintenance and improve its access roads for these two transmission lines. This paper discusses the impacts to the existing environment as well as the environmental consequences resulting from the maintenance and construction that is proposed.

Not Available

1993-07-01T23:59:59.000Z

143

Environmental Assessment and Finding of No Significant Impact: Curecanti-Lost Canyon 230-kV Transmission Line Reroute Project, Montrose County, Colorado  

SciTech Connect (OSTI)

The Department of Energy (DOE), Western Area Power Administration (Western) is proposing to reroute a section of the Curecanti-Lost Canyon 230-kilovolt (kV) transmission line, in Montrose County, Colorado. A portion of the transmission line, situated 11 miles southeast of Montrose, Colorado, crosses Waterdog Peak, an area of significant geologic surface activity, which is causing the transmission line's lattice steel towers to shift. This increases stress to structure hardware and conductors, and poses a threat to the integrity of the transmission system. Western proposes to relocate the lattice steel towers and line to a more geologically stable area. The existing section of transmission line and the proposed relocation route cross Bureau of Land Management and private land holdings.

N /A

2000-03-20T23:59:59.000Z

144

ESS 2012 Peer Review - 15 kV Phase Leg Power Modules with SiC Devices - Ranbir Singh, GeneSiC Semiconductor  

Broader source: Energy.gov (indexed) [DOE]

1 1 Click to edit Master title style 15 kV Phase Leg Power Modules with SiC MIDSJT Devices Ranbir Singh and Siddarth Sundaresan GeneSiC Semiconductor Inc. ranbir.singh@genesicsemi.com +1 703 996 8200 43670 Trade Center Pl #155; Dulles VA 20166 September 27, 2012 Acknowledgement: The authors thank Dr. Imre Gyuk for funding this work and Dr. Stan Atcitty for technical supervision Sandia National Laboratories is a multi- program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000. DOE SBIR HV DC Link Grant #SC0008240 2 Phase Leg forms fundamental building block for AC/DC AND DC/AC Conversion

145

GENERATION OF A 5A, 10kV HOLLOW ELECTRON BEAM BY A PIERCE GUN J.J. BARROSO, P.J. CASTRO, J.O. ROSSI, J.A.N. GONALVES, and H. PATIRE JR.  

E-Print Network [OSTI]

GENERATION OF A 5A, 10kV HOLLOW ELECTRON BEAM BY A PIERCE GUN J.J. BARROSO, P.J. CASTRO, J.O. ROSSI experienced by the electron beam propagating across the cavity. Here we describe a Pierce gun used of short-circuits. PULSE GENERATOR VIEW GUN OPERATION The gun cathode voltage is fixed at the nominal value

146

Proposed amendment for Presidential Permit PP-63 and associated modifications to 500 kV international transmission line, Forbes, Minnesota to Manitoba, Canada Northern States Power Company. Final Environmental Assessment  

SciTech Connect (OSTI)

Northern States Power Company, (NSP), a Minnesota investor owned utility has applied to the Office of Fossil Energy, United States Department of Energy, to amend Presidential Permit PP-63 to allow for alterations to the 500 kV transmission line and as sedated facilities currently regulated by this permit. The alterations proposed for the 500 kV line owned by NSP are part of a long term effort sponsored by NSP to upgrade the existing NSP transmission system to allow for increased exchange of electricity with the Manitoba Hydro-Electric Board. Presidential Permit PP-63 authorized NSP to construct, connect, operate and maintain a 500 kV line at the United States/Canadian border approximately seven-and-a-half miles west of Warroad in Roseau County, Minnesota. This line connects with a 500 kV line owned and operated by the Manitoba Hydro-Electric Board (MHEB), which extends from Dorsey, Manitoba, Canada to the United States/Canadian border. NSP proposes to increase the electricity transfer capability of this transmission facility by constructing a new 80-acre substation on the existing 500 kV line in Roseau County, Minnesota, and upgrading the existing substation at Forbes, Minnesota. The proposed Roseau substation would contain two 41.5 ohm series capacitor banks. In addition, static VAR compensators are to be installed at the existing Forbes Substation. Approximately 5 acres would be added to the 30-acre Forbes site to house the additional equipment. No new lines would enter or exit the facility. NSP proposes to place the new Roseau Substation in service in May 1993 and to complete the upgrading of the Forbes Substation in March 1994. The primary, initial purpose of these modifications is to enable NSP to import 400 megawatts of electric power from MHEB during the summer months to meet peak electrical demand in the Minneapolis-St. Paul area. It is expected that this power transfer would begin in 1993.

Not Available

1992-02-01T23:59:59.000Z

147

Fast, accurate, and robust automatic marker detection for motion correction based on oblique kV or MV projection image pairs  

SciTech Connect (OSTI)

Purpose: A robust and accurate method that allows the automatic detection of fiducial markers in MV and kV projection image pairs is proposed. The method allows to automatically correct for inter or intrafraction motion. Methods: Intratreatment MV projection images are acquired during each of five treatment beams of prostate cancer patients with four implanted fiducial markers. The projection images are first preprocessed using a series of marker enhancing filters. 2D candidate marker locations are generated for each of the filtered projection images and 3D candidate marker locations are reconstructed by pairing candidates in subsequent projection images. The correct marker positions are retrieved in 3D by the minimization of a cost function that combines 2D image intensity and 3D geometric or shape information for the entire marker configuration simultaneously. This optimization problem is solved using dynamic programming such that the globally optimal configuration for all markers is always found. Translational interfraction and intrafraction prostate motion and the required patient repositioning is assessed from the position of the centroid of the detected markers in different MV image pairs. The method was validated on a phantom using CT as ground-truth and on clinical data sets of 16 patients using manual marker annotations as ground-truth. Results: The entire setup was confirmed to be accurate to around 1 mm by the phantom measurements. The reproducibility of the manual marker selection was less than 3.5 pixels in the MV images. In patient images, markers were correctly identified in at least 99% of the cases for anterior projection images and 96% of the cases for oblique projection images. The average marker detection accuracy was 1.4{+-}1.8 pixels in the projection images. The centroid of all four reconstructed marker positions in 3D was positioned within 2 mm of the ground-truth position in 99.73% of all cases. Detecting four markers in a pair of MV images takes a little less than a second where most time is spent on the image preprocessing. Conclusions: The authors have developed a method to automatically detect multiple markers in a pair of projection images that is robust, accurate, and sufficiently fast for clinical use. It can be used for kV, MV, or mixed image pairs and can cope with limited motion between the projection images.

Slagmolen, Pieter; Hermans, Jeroen; Maes, Frederik; Budiharto, Tom; Haustermans, Karin; Heuvel, Frank van den [Department of ESAT, Medical Image Computing, Catholic University Leuven, Leuven 3000 (Belgium) and Department of Radiology, Medical Image Computing, Catholic University Leuven, Leuven 3000 (Belgium); Department of Radiotherapy, University Hospitals Leuven, Leuven 3000 (Belgium)

2010-04-15T23:59:59.000Z

148

rates | OpenEI  

Open Energy Info (EERE)

rates rates Dataset Summary Description This dataset, compiled by NREL and Ventyx, provides average residential, commercial and industrial electricity rates by zip code for both investor owned utilities (IOU) and non-investor owned utilities. Note: the file includes average rates for each utility, but not the detailed rate structure data found in the database available via the zip-code look-up feature on the OpenEI Utilities page (http://en.openei.org/wiki/Gateway:Utilities). The data was released by NREL/Ventyx in February 2011. Source NREL and Ventyx Date Released February 24th, 2012 (2 years ago) Date Updated Unknown Keywords electric rates rates US utilities Data text/csv icon IOU rates by zipcode (csv, 1.7 MiB) text/csv icon Non-IOU rates by zipcode (csv, 2.1 MiB)

149

Historical Interest Rates  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Current and Historical Interest Rates Current and Historical Interest Rates The table lists interest rates, from the project's inception through the present, for all projects with repayment supervised by the CRSP MC. The latest available interest rate is used for all future interest rate calculations. The Amistad-Falcon, Collbran, Provo River, and Rio Grande Projects are all assigned the average daily "Yield Rate" calculated by the U.S. Treasury, on an annual basis, for Treasury bonds having terms of 15 years or more remaining to maturity. The calculated yield rate is rounded to the nearest one-eighth of one percent. The yield rate is based upon the bond's interest rate, as well as its market value. The Colorado River Storage Project and its participating projects, Dolores and Seedskadee, are assigned the average daily "Coupon Rate," annualized for the same U.S. Treasury bonds used in "Yield Rate" calculations. The coupon rate is the interest rate that the bond carries upon its face.

150

Cost Analysis Rate Settin  

E-Print Network [OSTI]

Cost Analysis and Rate Settin for Animal Research Facilities #12;#12;Cost Analysis and Rate ... .. . ...................... . . . ................................. . .... 7 Chapter 2 Preparation for Cost Analysis ......................................................... 9 Chapter 3 Assignment of Costs to Animal Research Facility Cost Centers

Baker, Chris I.

151

2.3-MW Medium-Voltage, Three-Level Wind Energy Inverter Applying a Unique Bus Structure and 4.5-kV Si/SiC Hybrid Isolated Power Modules: Preprint  

SciTech Connect (OSTI)

A high-efficiency, 2.3-MW, medium-voltage, three-level inverter utilizing 4.5-kV Si/SiC (silicon carbide) hybrid modules for wind energy applications is discussed. The inverter addresses recent trends in siting the inverter within the base of multimegawatt turbine towers. A simplified split, three-layer laminated bus structure that maintains low parasitic inductances is introduced along with a low-voltage, high-current test method for determining these inductances. Feed-thru bushings, edge fill methods, and other design features of the laminated bus structure provide voltage isolation that is consistent with the 10.4-kV module isolation levels. Inverter efficiency improvement is a result of the (essential) elimination of the reverse recovery charge present in 4.5-kV Si PIN diodes, which can produce a significant reduction in diode turn-off losses as well as insulated-gate bipolar transistor (IGBT) turn-on losses. The hybrid modules are supplied in industry-standard 140 mm x 130 mm and 190 mm x 130 mm packages to demonstrate direct module substitution into existing inverter designs. A focus on laminated bus/capacitor-bank/module subassembly level switching performance is presented.

Erdman, W.; Keller, J.; Grider, D.; VanBrunt, E.

2014-11-01T23:59:59.000Z

152

About the Ratings  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

2008 Ratings Changes 2008 Ratings Changes EPA's "New" Fuel Economy Ratings Video about EPA's New Fuel Economy Ratings Windows Media Video (6.8 MB) Quicktime Video (7.8 MB) Text Version EPA changed the way it estimates fuel economy starting with the 2008 model year. This "new" way of estimating fuel economy supplements the previous method by incorporating the effects of Faster speeds and acceleration Air conditioner use Colder outside temperatures What else do I need to know about the "new" ratings? The tests lower MPG estimates for most vehicles. View old/new MPG ratings for a specific vehicle The actual mileage you get will still vary based on your driving habits, traffic conditions, and other factors. All MPG estimates in Find-a-Car have been converted to the new

153

Effective Rate Period  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Fiscal Year 2014 Fiscal Year 2014 Effective Rate Period As of Beginning of the FY 10/01/2013 - 09/30/2014 Mid-Year Changes (if applicable) 10/01/2013 - 09/30/2014 Power Rates Annual Revenue Requirement Rate Schedule Power Revenue Requirement $73,441,557 CV-F13 Base Resource Revenue Requirement $69,585,875 First Preference Revenue Requirement $3,855,682

154

LCC Guidance Rates  

Broader source: Energy.gov [DOE]

Notepad text file provides the LCC guidance rates in a numbered format for the various regions throughout the U.S.

155

Draft Tiered Rate Methodology  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

year's weather and other specific factors are removed from the loads of irrigated agriculture. ( ) "Irrigation Rate Mitigation" means the form of a discount by BPA to...

156

Heart Rate Artifact Suppression.  

E-Print Network [OSTI]

??Motion artifact strongly corrupts heart rate measurements in current pulse oximetry systems. In many, almost any motion will greatly diminish the system’s ability to extract… (more)

Dickson, Christopher

2012-01-01T23:59:59.000Z

157

Residential Solar Valuation Rates  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Residential Solar Valuation Rates Karl R. Rbago Rbago Energy LLC 1 The Ideal Residential Solar Tariff Fair to the utility and non-solar customers Fair compensation to...

158

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... ACS MEMBER RATES "Situations Wanted" advertisements will be classified by the chemical held designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

2000-02-21T23:59:59.000Z

159

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... ACS MEMBER RATES "Situations Wanted" advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

1997-03-24T23:59:59.000Z

160

2007-2009 Power Rate Adjustments (pbl/rates)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Function Review (PFR) Firstgov FY 2007 2009 Power Rate Adjustments BPA's 2007-2009 Wholesale Power Rate Schedules and General Rate Schedule Provisions (GRSPs) took effect on...

Note: This page contains sample records for the topic "kv rating mva" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

OpenEI - rates  

Open Energy Info (EERE)

U.S. Electric Utility U.S. Electric Utility Companies and Rates: Look-up by Zipcode (Feb 2011) http://en.openei.org/datasets/node/899 This dataset, compiled by NREL and Ventyx, provides average residential, commercial and industrial electricity rates by zip code for both investor owned utilities (IOU) and non-investor owned utilities. Note: the file includes average rates for each utility, but not the detailed rate structure data found in the database available via the zip-code look-up feature on the OpenEI Utilities page (http://en.openei.org/wiki/Gateway:Utilities). The data was released by NREL/Ventyx in February 2011.

162

Water Rate Escalations  

Broader source: Energy.gov [DOE]

Federal agencies need accurate water cost escalation rates to perform life cycle cost analyses for water efficiency projects to meet Executive Order 13514 and Energy Independence and Security Act...

163

Before a Rate Case  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

is made up of two processes. The first part of the IBR is the Integrated Program Review (IPR), which will address proposed program costs prior to their inclusion in a rate case,...

164

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted "advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202. ...

2002-04-15T23:59:59.000Z

165

Tiered Rate Methodology  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Rate Period limit. This 23 exception is limited for the duration of this TRM to the first ten requesting utilities that 24 BP-12-A-03 Section 4 Page 46 meet the size threshold and...

166

Ashland Area Support Substation Project : Environmental Assessment.  

SciTech Connect (OSTI)

The Bonneville Power Administration (BPA) provides wholesale electric service to the City of Ashland (the City) by transferring power over Pacific Power & Light Company`s (PP&L) 115-kilovolt (kV) transmission lines and through PP&L`s Ashland and Oak Knoll Substations. The City distributes power over a 12.5-kV system which is heavily loaded during winter peak periods and which has reached the limit of its ability to serve peak loads in a reliable manner. Peak loads under normal winter conditions have exceeded the ratings of the transformers at both the Ashland and Oak Knoll Substations. In 1989, the City modified its distribution system at the request of PP&L to allow transfer of three megawatts (MW`s) of electric power from the overloaded Ashland Substation to the Oak Knoll Substation. In cooperation with PP&L, BPA installed a temporary 6-8 megavolt-amp (MVA) 115-12.5-kV transformer for this purpose. This additional transformer, however, is only a temporary remedy. BPA needs to provide additional, reliable long-term service to the Ashland area through additional transformation in order to keep similar power failures from occurring during upcoming winters in the Ashland area. The temporary installation of another 20-MVA mobile transformer at the Ashland Substation and additional load curtailment are currently being studied to provide for sustained electrical service by the peak winter period 1992. Two overall electrical plans-of-service are described and evaluated in this report. One of them is proposed for action. Within that proposed plan-of-service are location options for the substation. Note that descriptions of actions that may be taken by the City of Ashland are based on information provided by them.

United States. Bonneville Power Administration.

1992-06-01T23:59:59.000Z

167

Ashland Area Support Substation Project  

SciTech Connect (OSTI)

The Bonneville Power Administration (BPA) provides wholesale electric service to the City of Ashland (the City) by transferring power over Pacific Power Light Company's (PP L) 115-kilovolt (kV) transmission lines and through PP L's Ashland and Oak Knoll Substations. The City distributes power over a 12.5-kV system which is heavily loaded during winter peak periods and which has reached the limit of its ability to serve peak loads in a reliable manner. Peak loads under normal winter conditions have exceeded the ratings of the transformers at both the Ashland and Oak Knoll Substations. In 1989, the City modified its distribution system at the request of PP L to allow transfer of three megawatts (MW's) of electric power from the overloaded Ashland Substation to the Oak Knoll Substation. In cooperation with PP L, BPA installed a temporary 6-8 megavolt-amp (MVA) 115-12.5-kV transformer for this purpose. This additional transformer, however, is only a temporary remedy. BPA needs to provide additional, reliable long-term service to the Ashland area through additional transformation in order to keep similar power failures from occurring during upcoming winters in the Ashland area. The temporary installation of another 20-MVA mobile transformer at the Ashland Substation and additional load curtailment are currently being studied to provide for sustained electrical service by the peak winter period 1992. Two overall electrical plans-of-service are described and evaluated in this report. One of them is proposed for action. Within that proposed plan-of-service are location options for the substation. Note that descriptions of actions that may be taken by the City of Ashland are based on information provided by them.

Not Available

1992-06-01T23:59:59.000Z

168

Stocking Rate Decisions  

E-Print Network [OSTI]

to predict potential forage shortfalls, determine the im- pact of the decision on finances and other ranch re- sources, and make any necessary adjustments before the forage resource is harmed or financial problems occur. Through adequate planning and periodic... rates with limited knowledge of future forage and market conditions. But they can use past records, experience and range surveys to make realistic projections of forage and market conditions (Figure 3). Then, the planned stock- ing rate should...

White, Larry D.; McGinty, Allan

1999-02-15T23:59:59.000Z

169

On Thermonuclear Reaction Rates  

E-Print Network [OSTI]

Nuclear reactions govern major aspects of the chemical evolution od galaxies and stars. Analytic study of the reaction rates and reaction probability integrals is attempted here. Exact expressions for the reaction rates and reaction probability integrals for nuclear reactions in the case of nonresonant, modified nonresonant, screened nonresonant and resonant cases are given. These are expressed in terms of H-functions, G-functions and in computable series forms. Computational aspects are also discussed.

H. J. Haubold; A. M. Mathai

1996-12-02T23:59:59.000Z

170

Cat Heart Rate Monitoring  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Cat Heart Rate Monitoring Cat Heart Rate Monitoring Name: Shakti Status: student Grade: 9-12 Location: TX Country: USA Date: Summer 2010 Question: What is the best way to find a cat's heart rate using a stethoscope? Because I have tried to hear their heart beat but their purring is all I can hear. If I shouldn't use a stethoscope, then what should I use? Replies: Hi Shakti! If you want to use a stethoscope, the trick is to get your cat to stop purring. Two good ways that I have found to help stop the purring 1. Cover their nose (generally cats don't like this and will stop purring) or 2. Put on the tap to drip or lightly stream water (also, they generally don't like this and will stop purring). Alternatively, you can get their heart rate from feeling their pulse. A good place to try to feel a pulse is right where the leg attaches to the abdomen - in an area called the inguinal region. Now granted there are some heart conditions that will cause an animals pulse and their heart rates don't match up, and it's hard to feel if you have a fat cat, but it's a good place to try if you are really trying to get a heart rate in a healthy kitty!

171

October 2001 - September 2006 Wholesale Power Rates (rates/previous...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

October 2001 - September 2006 The 2002 Wholesale Power Rate Schedules (base rates) for the FY 2002-2006 rate period were originally established in May 2000 during the WP-02 Rate...

172

Upper Great Plains Rates information  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Rates and Repayment Services Rates and Repayment Services Rates 2010 Firm Power Rate (effective January 1, 2010) Rate Adjustments 2010 Firm Power Rate Adjustment 2009 Firm Power Rate Adjustment IS Rate Adjustments Rate Adjustment Process Rate Orders Signed, December 23, 2009 (16kb pdf) Announcements Firm Electric Service Customer Letter - Preliminary Review of Drought Adder Component, June 27, 2013 (74kb pdf) Customer Letter - Final Notice of Drought Adder Component, October 2, 2013 (68kb pdf) Integrated System (IS) Rates 2014 IS Rates Customer Information Meeting Presentation, October 15, 2013 (611kb pdf) Customer Letter - Notification of 2014 Rates, September 13, 2013 (160kb pdf) 2014 Transmission and Ancillary Services Rate Calculation and 2012 Rate True-up Calculation (4.9mb pdf) 2013 IS Rates

173

BCP Annual Rate Process  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

2013 BCP Annual Rate Process 2013 BCP Annual Rate Process Informal Process Rate Activity Schedule (doc) Informal Customer Meeting Thursday March 6, 2013 at 10:30 A.M. Conf Rms 3&4 Informal Customer Meeting Presentation (Pdf) PRS Executive Summary (Mar 07, 2013) (Pdf) FY2014 Final Ten Year Operating Plan PRS Executive Summary (PDF) FORM for Foreign Visits (doc) Formal Process Initial Federal Register Notice (pdf) Public Information Forum March 27,2013 at 10:30 A.M. Conf Rms3&4 Customer Meeting Presentation PIF Presentation (PPT) Presentation Details (pdf) Reclamation Fund Status Report PIF PRS Executive Summary (pdf) PIF Transcripts (PDF) Visitor Center Cost Analysis Questions - Responses Public Comment Forum April 10, 2013 at 10:30 A.M. Conf Rms3&4 PCF Transcripts Customer Letters

174

Multiple System Rate Process  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

DSW Multiple System Transmission Rate Process DSW Multiple System Transmission Rate Process Federal Register Notice Withdrawing Rate Proposal (PDF) Formal Process Extension Federal Register Notice (PDF) Customer Savings Under Various MSTR (XLS) Public Information Forum March 29, 2005 Customer Meeting Overview (Power Point) Customer Meeting Overview (PDF) Customer Meeting Transcript (PDF) Public Comment Forum April 6, 2005 Customer Meeting Transcript (PDF) Response Letter 5-17-05 (PDF) Customer Letters Tonopah ID-5/25/05 (PDF) APS-5/26/05 (PDF) SRP-5/27/05 (PDF) RSLynch-6/1/05 (PDF) KRSaline-6/1/05 (PDF) Formal Process Federal Register Notice (Word) Federal Register Notice (PDF) Brochure (Word) Appendices to Brochure: A B C D E1 E2 F1 F2 GH Public Information Forum July 14, 2004 Customer Meeting Overview (Power Point)

175

Obsidian Hydration Rates  

Science Journals Connector (OSTI)

...OBSIDIAN HYDRATION RATE FOR KLAMATH BASIN OF CALIFORNIA AND OREGON...as the material is excreted, falls through the air, and dries...Friedman. Table 1 presents two new groups of hydra-tion readings for...the true age is believed to fall (3). The Snaketown age is...

Clement W. Meighan

1970-10-02T23:59:59.000Z

176

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted" advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

2002-03-04T23:59:59.000Z

177

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted" advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

1999-10-25T23:59:59.000Z

178

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted"advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

2002-12-23T23:59:59.000Z

179

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted" advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19067-1612. ...

1997-04-07T23:59:59.000Z

180

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted" advertisements wilt be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

2003-09-15T23:59:59.000Z

Note: This page contains sample records for the topic "kv rating mva" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted"advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

2002-03-25T23:59:59.000Z

182

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted" advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

1999-08-16T23:59:59.000Z

183

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted" advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

2000-06-12T23:59:59.000Z

184

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted"advertisements wilt be classified by the chemical field designated by the members, if not designated, placement will be determined by the first word of the text submitted. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

2002-05-27T23:59:59.000Z

185

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted" advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Koad, Suite 202, Wayne, PA 19087-1612. ...

1998-04-20T23:59:59.000Z

186

Environmental Assessment and Finding of No Significant Impact: Western's Hoover Dam Bypass Project Phase II (Double-Circuiting a Portion of the Hoover-Mead No.5 and No.7 230-kV Transmission Lines with the Henderson-Mead No.1 230-kV Transmission Line, Clark County, Nevada)  

SciTech Connect (OSTI)

The U.S. Highway 93 (U.S. 93) Hoover Dam Bypass Project calls for the U.S. Department of Energy (DOE) Western Area Power Administration (Western) to remove its Arizona and Nevada (A&N) Switchyard. As a result of this action, Western must reconfigure its existing electrical transmission system in the Hoover Dam area. Western proposes to double-circuit a portion of the Hoover-Mead No.5 and No.7 230-kV Transmission Lines with the Henderson-Mead No.1 Transmission Line (see Figure 1-1). Double-circuiting is the placement of two separate electrical circuits, typically in the form of three separate conductors or bundles of conductors, on the same set of transmission line structures. The old Henderson-Hoover 230-kV Transmission Line would become the new Henderson-Mead No.1 and would extend approximately eight miles to connect with the Mead Substation. Western owns, operates, and maintains the Hoover-Mead No.5 and No.7, and Henderson-Hoover electrical power transmission lines. Additionally, approximately 0.25 miles of new right-of-way (ROW) would be needed for the Henderson-Mead No.1 when it transfers from double-circuiting with the Hoover-Mead No.7 to the Hoover-Mead No.5 at the Boulder City Tap. The proposed project would also involve a new transmission line ROW and structures where the Henderson-Mead No.1 will split from the Hoover-Mead No.5 and enter the northeast corner of the Mead Substation. Lastly, Western has proposed adding fiber optic overhead ground wire from the Hoover Power Plant to the Mead Substation on to the Henderson-Mead No.1, Hoover-Mead No.5 and No.7 Transmission Lines. The proposed project includes replacing existing transmission line tower structures, installing new structures, and adding new electrical conductors and fiber optic cables. As a consequence of these activities, ground disturbance may result from grading areas for structure placement, constructing new roads, improving existing roads for vehicle and equipment access, and from installing structures, conductors, and fiber optic cables. Project construction activities would be conducted within the existing 200-foot transmission line ROW and 50-foot access road ROW, although new spur access roads could occur outside of existing ROWs. As lead Federal agency for this action under National Environmental Policy Act (NEPA), Western must ensure that adverse environmental effects on Federal and non-Federal lands and resources are avoided or minimized. This Environmental Assessment (EA) is intended to be a concise public document that assesses the probable and known impacts to the environment from Western's Proposed Action and alternatives, and reaches a conclusion about the significance of the impacts. This EA was prepared in compliance with NEPA regulations published by the Council on Environmental Quality (40 CFR 1500-1508) and implementing procedures of the Department of Energy (10 CFR 1021).

N /A

2003-10-27T23:59:59.000Z

187

Rail Coal Transportation Rates  

U.S. Energy Information Administration (EIA) Indexed Site

reports reports Coal Transportation Rates to the Electric Power Sector With Data through 2010 | Release Date: November 16, 2012 | Next Release Date: December 2013 | Correction Previous editions Year: 2011 2004 Go Figure 1. Deliveries from major coal basins to electric power plants by rail, 2010 Background In this latest release of Coal Transportation Rates to the Electric Power Sector, the U.S. Energy Information Administration (EIA) significantly expands upon prior versions of this report with the incorporation of new EIA survey data. Figure 1. Percent of total U.S. rail shipments represented in data figure data Previously, EIA relied solely on data from the U.S. Surface Transportation Board (STB), specifically their confidential Carload Waybill Sample. While valuable, due to the statistical nature of the Waybill data,

188

Plant Tumor Growth Rates  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Plant Tumor Growth Rates Plant Tumor Growth Rates Name: Gina and Maria Location: N/A Country: N/A Date: N/A Question: We are doing a science fair project on if B. Carotene, Green tea, and Grape Seed Extract helps plants against the crown gall disease. We injected sunflowers with agrobacterium tum. one week ago (Sun. Feb. 27, 2000). Our questions is how long will it take for the tumors to grow? We scratched the surface of the stems and injected the agrobacterium in the wound. Also which do you think, in your opinion, will do the best, if any? Our science fair is April 13, do you think we'll have growth before then, atleast enough time to do our conclusion and results? Thank you, any information you forward will be very helpful. Replies: Sunflowers form galls relatively quickly. I usually get them in two weeks at least. Good luck.

189

Adjusted Growth Rates*  

U.S. Energy Information Administration (EIA) Indexed Site

Jan. '99 to Feb. '99: -1.7% Feb. '98 to Feb. '99: +19.8% YTD '98 to YTD '99: +15.0% 4,100 4,400 4,700 5,000 5,300 5,600 5,900 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons U.S. Distillate Fuel Sales 2011 2012 2013 Adjusted Growth Rates* Jul '13 to Aug '13: 2.5% Aug '12 to Aug '13: -1.3% YTD '12 to YTD '13: 1.5% 300 400 500 600 700 800 900 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons U.S. Residual Fuel Sales 2011 2012 2013 Adjusted Growth Rates* Jul '13 to Aug '13: -0.8%

190

Adjusted Growth Rates* Jan.  

U.S. Energy Information Administration (EIA) Indexed Site

Adjusted Adjusted Growth Rates* Jan. '99 to Feb. '99: -1.7% Feb. '98 to Feb. '99: +19.8% YTD '98 to YTD '99: +15.0% U.S. Distillate Fuel Sales 3,000 3,500 4,000 4,500 5,000 5,500 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1998 1999 2000 Adjusted Growth Rates* Dec '99 to Jan '00: -7.4% Jan '99 to Jan '00: -0.1% YTD '99 to YTD '00: -0.1% U.S. Motor Gasoline Sales 8,000 9,000 10,000 11,000 12,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1998 1999 2000 Adjusted Growth Rates* Dec '99 to Jan '00: -16.8% Jan '99 to Jan '00: -3.2% YTD '99 to YTD '00: -3.2% U.S. Kerosene-Type Jet Fuel Sales 1,500 1,600 1,700 1,800 1,900 2,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1998 1999 2000 Adjusted Growth Rates* Dec '99 to Jan '00: -9.3% Jan '99 to Jan '00: +3.5% YTD '99 to YTD '00: +3.5% U.S. Propane Sales 600 800 1,000 1,200 1,400 1,600 1,800 Jan Feb Mar Apr May Jun Jul

191

Rate Adjustments and Public Involvement  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Rate Adjustments and Public Involvement Documents Rate Adjustments and Public Involvement Documents CRSP Transmission 9/16/2013 WAPA-161 FRN, CRSP transmission and ancillary services rates extension Letter announcing two-year extension to CRSP transmission and ancillary services rates Letter announcing revised CRSP transmission rates for FY 2014 Accompanying calculation table for FY 2014 CRSP transmission rate letter Letter announcing revised CRSP transmission rates for FY 2013 Letter announcing revised CRSP transmission rates for FY 2012 Letter announcing revised CRSP transmission rates for FY 2011 Letter announcing revised CRSP transmission rates for FY 2010 SLCA/IP 9/16/2013 WAPA-161 FRN, SLCA/IP firm power rate extension Letter announcing two-year extension to SLCA/IP firm power rate SLCA/IP Tentative Rate Adjustment Schedule

192

Adjusted Growth Rates*  

U.S. Energy Information Administration (EIA) Indexed Site

June '99 to July '99: -5.4% June '99 to July '99: -5.4% July '98 to July '99: +3.3% YTD '98 to YTD '99: +6.3% U.S. Motor Gasoline Sales 8,000 9,000 10,000 11,000 12,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* June '99 to July '99: -0.5% July '98 to July '99: -0.4% YTD '98 to YTD '99: +1.1% U.S. Kerosene-Type Jet Fuel Sales 1,500 1,600 1,700 1,800 1,900 2,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* June '99 to July '99: +0.5% July '98 to July '99: +1.0% YTD '98 to YTD '99: -0.3% U.S. Propane Sales 600 800 1,000 1,200 1,400 1,600 1,800 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* June '99 to July '99: +1.5% July '98 to July '99: +10.2% YTD '98 to YTD '99: +7.2%

193

Adjusted Growth Rates*  

U.S. Energy Information Administration (EIA) Indexed Site

Nov '99 to Dec '99: +5.3% Nov '99 to Dec '99: +5.3% Dec '98 to Dec '99: +8.7% YTD '98 to YTD '99: +5.0% U.S. Motor Gasoline Sales 8,000 9,000 10,000 11,000 12,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Nov '99 to Dec '99: +6.0% Dec '98 to Dec '99: +4.5% YTD '98 to YTD '99: +1.3% U.S. Kerosene-Type Jet Fuel Sales 1,500 1,600 1,700 1,800 1,900 2,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Nov '99 to Dec '99: +2.4% Dec '98 to Dec '99: +3.0% YTD '98 to YTD '99: +0.9% U.S. Propane Sales 600 800 1,000 1,200 1,400 1,600 1,800 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Nov '99 to Dec '99: +32.3% Dec '98 to Dec '99: +2.0% YTD '98 to YTD '99: +5.5%

194

Adjusted Growth Rates*  

U.S. Energy Information Administration (EIA) Indexed Site

July '99 to Aug. '99: +4.7% July '99 to Aug. '99: +4.7% Aug. '98 to Aug. '99: +1.3% YTD '98 to YTD '99: +4.7% U.S. Motor Gasoline Sales 8,000 9,000 10,000 11,000 12,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* July '99 to Aug. '99: -1.9% Aug. '98 to Aug. '99: -0.4% YTD '98 to YTD '99: +0.9% U.S. Kerosene-Type Jet Fuel Sales 1,500 1,600 1,700 1,800 1,900 2,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* July '99 to Aug. '99: -0.1% Aug. '98 to Aug. '99: -1.4% YTD '98 to YTD '99: -0.7% U.S. Propane Sales 600 800 1,000 1,200 1,400 1,600 1,800 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* July '99 to Aug. '99: +22.3% Aug. '98 to Aug. '99: +21.1%

195

Adjusted Growth Rates*  

U.S. Energy Information Administration (EIA) Indexed Site

Aug '99 to Sep '99: +4.9% Aug '99 to Sep '99: +4.9% Sep '98 to Sep '99: +4.7% YTD '98 to YTD '99: +4.7% U.S. Motor Gasoline Sales 8,000 9,000 10,000 11,000 12,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Aug '99 to Sep '99: -2.4% Sep '98 to Sep '99: +0.4% YTD '98 to YTD '99: +1.3% U.S. Kerosene-Type Jet Fuel Sales 1,500 1,600 1,700 1,800 1,900 2,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Aug '99 to Sep '99: -2.1% Sep '98 to Sep '99: +4.6% YTD '98 to YTD '99: 0.0% U.S. Propane Sales 600 800 1,000 1,200 1,400 1,600 1,800 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Aug '99 to Sep '99: +7.3% Sep '98 to Sep '99: +8.4% YTD '98 to YTD '99: +8.3%

196

Adjusted Growth Rates*  

U.S. Energy Information Administration (EIA) Indexed Site

Oct '99 to Nov '99: +0.1% Oct '99 to Nov '99: +0.1% Nov '98 to Nov '99: +5.5% YTD '98 to YTD '99: +4.5% U.S. Motor Gasoline Sales 8,000 9,000 10,000 11,000 12,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Oct '99 to Nov '99: -0.7% Nov '98 to Nov '99: +1.7% YTD '98 to YTD '99: +1.1% U.S. Kerosene-Type Jet Fuel Sales 1,500 1,600 1,700 1,800 1,900 2,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Oct '99 to Nov '99: +2.5% Nov '98 to Nov '99: +6.0% YTD '98 to YTD '99: +0.8% U.S. Propane Sales 600 800 1,000 1,200 1,400 1,600 1,800 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Oct '99 to Nov '99: +9.7% Nov '98 to Nov '99: +2.2% YTD '98 to YTD '99: +6.2%

197

Adjusted Growth Rates*  

U.S. Energy Information Administration (EIA) Indexed Site

Sep '99 to Oct '99: +3.9% Sep '99 to Oct '99: +3.9% Oct '98 to Oct '99: +2.3% YTD '98 to YTD '99: +4.4% U.S. Motor Gasoline Sales 8,000 9,000 10,000 11,000 12,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Sep '99 to Oct '99: -0.2% Oct '98 to Oct '99: -0.9% YTD '98 to YTD '99: +1.0% U.S. Kerosene-Type Jet Fuel Sales 1,500 1,600 1,700 1,800 1,900 2,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Sep '99 to Oct '99: -1.9% Oct '98 to Oct '99: -0.7% YTD '98 to YTD '99: +0.4% U.S. Propane Sales 600 800 1,000 1,200 1,400 1,600 1,800 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Sep '99 to Oct '99: -2.1% Oct '98 to Oct '99: -6.4% YTD '98 to YTD '99: +6.6%

198

Transportation Rates For Fishery Products  

E-Print Network [OSTI]

express (Railway Express Agency), and motor carriers. Air transporta- tion and water transportation 2 Rail-freight rates 2 Rail-express rates 3 Motor-carrier rates 3 Protective-service charges 4 used in sample 7 2. Rail-express rate index: Routes used in sample 7 3. Motor-carrier rate index

199

October 1996 - September 2001 Wholesale Power Rates (rates/previous...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

affecting a specific power purchase. For more specific information see: 1996 Final Wholesale Power and Transmission Rate Schedules: Power Rates (PDF, 84 pages, 188 kb) Ancillary...

200

NOx diesel exhaust treatment using a pulsed corona discharge: the pulse repetition rate effect  

Science Journals Connector (OSTI)

The pulsed corona offers real promise for degradation of pollutants in gas and water streams. This paper presents a study of NOx removal from diesel exhaust. Special emphasis is laid on the investigation of the dependence of the NO removal rate and efficiency on the pulse repetition rate (PRR). A nanosecond solid state power supply (45?kV, 60?ns, up to 1?kHz) was used for driving the corona reactor. A Mitsubishi 10?kW 3-cylinder diesel-generator engine with a total volume of 1300?cm3 was used as a source of exhaust gas. At an NO removal rate of 35% the NO removal efficiency was 53?g?kW?1h?1 for PRR = 500?Hz and the initial NO concentration was 375?ppm. A semi-empirical expression for the corona reactor removal efficiency related both to PRR and to the residence time is presented. The removal efficiency decreases with increasing PRR at constant flow rate or constant residence time. This expression demonstrates reasonable agreement between the calculation results and the experimental data.

Y Yankelevich; M Wolf; R Baksht; A Pokryvailo; J Vinogradov; B Rivin; E Sher

2007-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "kv rating mva" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Tier 2 Vintage Rate Workshop  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

4 Tier 2 Rate Alternatives Tier 2 Rate Alternatives Load Growth Rate BPA commits to meet Load Following customers' load growth placed on BPA for the term of the commitment period...

202

Plasma Adiabatic Lapse Rate  

Science Journals Connector (OSTI)

The plasma analog of an adiabatic lapse rate (or temperature variation with height) in atmospheric physics is obtained. A new source of plasma temperature gradient in a binary ion species mixture is found that is proportional to the concentration gradient ??? and difference in average ionization states Z2-Z1. Application to inertial-confinement-fusion implosions indicates a potentially strong effect in plastic (CH) ablators that is not modeled with mainline (single-fluid) simulations. An associated plasma thermodiffusion coefficient is derived, and charge-state diffusion in a single-species plasma is also predicted.

Peter Amendt; Claudio Bellei; Scott Wilks

2012-08-16T23:59:59.000Z

203

Rate types for stream programs  

Science Journals Connector (OSTI)

We introduce RATE TYPES, a novel type system to reason about and optimize data-intensive programs. Built around stream languages, RATE TYPES performs static quantitative reasoning about stream rates -- the frequency of data items in a stream being ... Keywords: data processing rates, data throughput, performance reasoning, stream programming, type systems

Thomas W. Bartenstein, Yu David Liu

2014-10-01T23:59:59.000Z

204

electric rates | OpenEI  

Open Energy Info (EERE)

electric rates electric rates Dataset Summary Description This dataset, compiled by NREL and Ventyx, provides average residential, commercial and industrial electricity rates by zip code for both investor owned utilities (IOU) and non-investor owned utilities. Note: the file includes average rates for each utility, but not the detailed rate structure data found in the database available via the zip-code look-up feature on the OpenEI Utilities page (http://en.openei.org/wiki/Gateway:Utilities). The data was released by NREL/Ventyx in February 2011. Source NREL and Ventyx Date Released February 24th, 2012 (2 years ago) Date Updated Unknown Keywords electric rates rates US utilities Data text/csv icon IOU rates by zipcode (csv, 1.7 MiB) text/csv icon Non-IOU rates by zipcode (csv, 2.1 MiB)

205

Rate Schedules | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Rate Schedules Rate Schedules Rate Schedules One of the major responsibilities of Southeastern is to design, formulate, and justify rate schedules. Repayment studies prepared by the agency determine revenue requirements and appropriate rate levels and these studies for each of Southeastern's four power marketing systems are updated annually. They demonstrate the adequacy of the rates for each system. Rates are considered to be adequate when revenues are sufficient to repay all costs associated with power production and transmission costs, which include the amortization of the Federal investment allocated to power. Latest Rate Schedules October 1, 2012 ALA-1-N Wholesale Power Rate Schedule Area: PowerSouth Energy Cooperative System: Georgia-Alabama-South Carolina October 1, 2012

206

2007-2009 Power Rates Quarterly Updates (pbl/rates)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

(PFR) Firstgov FY 2007 2009 Power Rates Quarterly Updates In BPAs 2007-2009 Wholesale Power Rate Case (WP-07), BPA agreed that it would post reports about BPAs power...

207

WP-07 Power Rate Case (rates/ratecases)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Rate Cases Financial Choices (2003-06) Power Function Review (PFR) Firstgov 2007 Wholesale Power (WP-07) Rate Case Related Links: Power Function Review (PFR) On July 17, 2006,...

208

National Utility Rate Database: Preprint  

SciTech Connect (OSTI)

When modeling solar energy technologies and other distributed energy systems, using high-quality expansive electricity rates is essential. The National Renewable Energy Laboratory (NREL) developed a utility rate platform for entering, storing, updating, and accessing a large collection of utility rates from around the United States. This utility rate platform lives on the Open Energy Information (OpenEI) website, OpenEI.org, allowing the data to be programmatically accessed from a web browser, using an application programming interface (API). The semantic-based utility rate platform currently has record of 1,885 utility rates and covers over 85% of the electricity consumption in the United States.

Ong, S.; McKeel, R.

2012-08-01T23:59:59.000Z

209

Rating the NRF's rating system Michael I. Cherry  

E-Print Network [OSTI]

the NRF's raison d'être--thetrainingofhigh-qualityresearch manpower. The progress of the rating systemRating the NRF's rating system Michael I. Cherry a* and Mark J. Gibbons b T HE LATEST REVIEW OF THE NATIONAL Research Foundation (NRF), chaired by Wieland Gevers, and released surreptitiously

Wagner, Stephan

210

SCHOOL OF MEDICINE TELECOMMUNICATIONS RATE  

E-Print Network [OSTI]

SCHOOL OF MEDICINE TELECOMMUNICATIONS RATE BACKGROUND The University recently the desktop phone service costs back to individual units/departments by creating a telecommunications rate in the Other Expenses category of the budget as a "Telecommunications Charge". NOTE- direct charging

Straight, Aaron

211

2007 Wholesale Power Rate Schedules : 2007 General Rate Schedule Provisions.  

SciTech Connect (OSTI)

This schedule is available for the contract purchase of Firm Power to be used within the Pacific Northwest (PNW). Priority Firm (PF) Power may be purchased by public bodies, cooperatives, and Federal agencies for resale to ultimate consumers, for direct consumption, and for Construction, Test and Start-Up, and Station Service. Rates in this schedule are in effect beginning October 1, 2006, and apply to purchases under requirements Firm Power sales contracts for a three-year period. The Slice Product is only available for public bodies and cooperatives who have signed Slice contracts for the FY 2002-2011 period. Utilities participating in the Residential Exchange Program (REP) under Section 5(c) of the Northwest Power Act may purchase Priority Firm Power pursuant to the Residential Exchange Program. Rates under contracts that contain charges that escalate based on BPA's Priority Firm Power rates shall be based on the three-year rates listed in this rate schedule in addition to applicable transmission charges. This rate schedule supersedes the PF-02 rate schedule, which went into effect October 1, 2001. Sales under the PF-07 rate schedule are subject to BPA's 2007 General Rate Schedule Provisions (2007 GRSPs). Products available under this rate schedule are defined in the 2007 GRSPs. For sales under this rate schedule, bills shall be rendered and payments due pursuant to BPA's 2007 GRSPs and billing process.

United States. Bonneville Power Administration.

2006-11-01T23:59:59.000Z

212

Commercial Building Asset Rating Program  

Broader source: Energy.gov [DOE]

Slides from a Commercial Building Initiative webinar outlining the Commercial Building Asset Rating Program on August 23, 2011.

213

Asymptotic Cellular Growth Rate as the Effective Information Utilization Rate  

E-Print Network [OSTI]

We study the average asymptotic growth rate of cells in randomly fluctuating environments. Using a game-theoretic perspective, we show that any response strategy has an asymptotic growth rate, which is the sum of: (i) the maximal growth rate at the worst possible distribution of environments, (ii) relative information between the actual distribution of environments to the worst one, and (iii) information utilization rate which is the information rate of the sensory devices minus the "information dissipation rate", the amount of information not utilized by the cell for growth. In non-stationary environments, the optimal strategy is the time average of the instantaneous optimal strategy and the optimal switching times are evenly spaced in the statistical (Fisher) metric.

Pugatch, Rami; Tlusty, Tsvi

2013-01-01T23:59:59.000Z

214

The Inverted Block Rate:The Inverted Block Rate: An Alternative to Flat Rate BillingAn Alternative to Flat Rate Billing  

E-Print Network [OSTI]

The Inverted Block Rate:The Inverted Block Rate: An Alternative to Flat Rate BillingAn Alternative;Inverted Block RateInverted Block Rate 22 IntroductionIntroduction ·· Modern societies rely on electrical collectionMetering and Rate Models facilitate collection #12;Inverted Block RateInverted Block Rate 33 Rate

Hughes, Larry

215

October 2003 - March 2004 Power Rates (rates/previous)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

3 - March 2004 (CRAC 5 period) "Monthly Adjusted" Wholesale Power Rates Effective October 2003 - March 2004 (CRAC 5 period) (PDF, 4 pages, 15 kb, corrected December 18, 2003,...

216

April - September 2004 Power Rates (rates/previous)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

4 (CRAC 6 period) "Monthly Adjusted" Wholesale Power Rates Effective April 1 - September 30, 2004 (CRAC 6 period) (PDF, 4 pages, 14 kb, originally posted January 12, 2004;...

217

April - September 2005 Power Rates (rates/previous)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

April - September 2005 (CRAC 8 period) "Monthly Adjusted" Wholesale Power Rates Effective April - September 2005 (CRAC 8 period) (PDF, 3 pages, 108 kb, posted December 17, 2004)...

218

October 2005 - March 2006 Power Rates (rates/previous)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

October 2005 - March 2006 (CRAC 9 period) "Monthly Adjusted" Wholesale Power Rates Effective October 2005 - March 2006 (CRAC 9 period) (PDF, 4 pages, 116 kb, originally posted...

219

Kinetics of interaction of Cotton Leaf Curl Kokhran Virus-Dabawali (CLCuKV-Dab) coat protein and its mutants with ssDNA  

SciTech Connect (OSTI)

Gemini viral assembly and transport of viral DNA into nucleus for replication, essentially involve DNA-coat protein interactions. The kinetics of interaction of Cotton Leaf Curl Kokhran Virus-Dabawali recombinant coat protein (rCP) with DNA was studied by electrophoretic mobility shift assay (EMSA) and surface plasmon resonance (SPR). The rCP interacted with ssDNA with a K{sub A}, of 2.6 +- 0.29 x 10{sup 8} M{sup -1} in a sequence non-specific manner. The CP has a conserved C2H2 type zinc finger motif composed of residues C68, C72, H81 and H85. Mutation of these residues to alanine resulted in reduced binding to DNA probes. The H85A mutant rCP showed the least binding with approximately 756 fold loss in the association rate and a three order magnitude decrease in the binding affinity as compared to rCP. The CP-DNA interactions via the zinc finger motif could play a crucial role in virus assembly and in nuclear transport.

Priyadarshini, C.G. Poornima [Department of Biochemistry, Indian Institute of Science, Bangalore 560012 (India); Savithri, H.S., E-mail: bchss@biochem.iisc.ernet.i [Department of Biochemistry, Indian Institute of Science, Bangalore 560012 (India)

2009-04-10T23:59:59.000Z

220

LEED for Homes Rating System affordablemarket rate multi-family  

E-Print Network [OSTI]

LEED for Homes Rating System affordablemarket rate multi-family #12;The top 25% of new homes based% REGULATIONS lawbreakers DEGREE OF GREEN MARKET SHIFT typical building practices market leaders innovators the negative impact of buildings on their occupants and on the environment. LEED for Homes categories

Zaferatos, Nicholas C.

Note: This page contains sample records for the topic "kv rating mva" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

The Coal Transportation Rate Database  

Gasoline and Diesel Fuel Update (EIA)

Coal Transportation Rate Database (CTRDB) adds new data for 2000 and 2001. The Federal Energy Regulatory Commission's (FERC) Form 580 "interrogatories" are the primary source for...

222

BPA revises oversupply rate proposal  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

oversupply-rate-proposal Sign In About | Careers | Contact | Investors | bpa.gov Search News & Us Expand News & Us Projects & Initiatives Expand Projects & Initiatives...

223

Amendment of Presidential Permit (PP-68) San Diego Gas & Electric Company for Interconnection of Otay Mesa Generating Project to Miguel-Tijuana 230 kV Transmission Line San Diego, California  

Broader source: Energy.gov (indexed) [DOE]

Section Page S:\COMM\NEPA\TODO \EA1383\EATOC1 -R.DOC 4/1/02 -i- 1.0 INTRODUCTION 1-1 1.1 BACKGROUND 1-1 1.2 SCOPE OF PROJECT 1-2 1.3 PURPOSE AND NEED 1-3 1.4 AGENCY ACTIONS 1-3 1.4.1 Federal 1-3 1.4.1.1 U.S. Department of Energy 1-3 1.4.1.2 U.S. Fish and Wildlife Service 1-4 1.4.2 Other Agenc y Actions 1-4 1.4.2.1 California Energy Commission 1-4 1.4.2.2 California Department of Fish and Game 1-4 1.4.2.3 State Historic Preservation Office 1-5 1.4.2.4 San Diego County 1-5 2.0 PROPOSED ACTION AND ALTERNATIVES 2-1 2.1 NO ACTION ALTERNATIVE 2-1 2.2 PROPOSED ACTION 2-1 2.2.1 Proposed Amendment to Presidential Permit (PP-68) 2-2 2.2.2 Description of Proposed Project Components and Activities 2-3 2.2.2.1 Otay Mesa 230 kV Switchyard 2-3

224

Draft environmental impact statement for construction and operation of the proposed Bangor Hydro-Electric Company`s second 345-kV transmission tie line to New Brunswick  

SciTech Connect (OSTI)

This Draft Environmental Impact Statement (DEIS) was prepared by the US Department of Energy (US DOE). The proposed action is the issuance of Presidential Permit PP-89 by DOE to Bangor Hydro-Electric Company to construct and operate a new international transmission line interconnection to New Brunswick, Canada that would consist of an 83.8 mile (US portion), 345-kilovolt (kV) alternating current transmission line from the US-Canadian border at Baileyville, Maine to an existing substation at Orrington, Maine. The principal environmental impacts of the construction and operation of the transmission line would be incremental in nature and would include the conversion of forested uplands (mostly commercial timberlands) and wetlands to right-of-way (small trees, shrubs, and herbaceous vegetation). The proposed line would also result in localized minor to moderate visual impacts and would contribute a minor incremental increase in the exposure of some individuals to electromagnetic fields. This DEIS documents the purpose and need for the proposed action, describes the proposed action and alternatives considered and provides a comparison of the proposed and alternatives routes, and provides detailed information on analyses of the environmental consequences of the proposed action and alternatives, as well as mitigative measures to minimize impacts.

NONE

1993-10-01T23:59:59.000Z

225

RECYCLING RATE STUDY Prepared by  

E-Print Network [OSTI]

NATIONAL RECYCLING RATE STUDY Prepared by: Smith, Bucklin and Associates, Inc. Market Research and Statistics Division Chicago, Illinois July 2003 PRINTED ON RECYCLED PAPER #12;BCI RECYCLING RATE STUDY TABLE ....................................................................................................1 II. METHODOLOGY A. Total Pounds of Lead Recycled from Batteries

Laughlin, Robert B.

226

Commercial Building Asset Rating Program  

Broader source: Energy.gov (indexed) [DOE]

1 eere.energy.gov 1 eere.energy.gov Commercial Building Asset Rating Program August 23, 2011 12 p.m. ET, 9 a.m. PT Presenter: Cody Taylor PRE-DECISIONAL Information included in this document is for discussion purposes and does not constitute the final program design. FOR INFORMATION ONLY 2 eere.energy.gov Outline * Goals * Scope & schedule * Guiding principles * Program design issues - Metrics - Rating method - Rating scale - Opportunities for efficiency improvement - Quality assurance Please submit clarifying questions during today's webinar via the Q&A function of Live Meeting. 3 eere.energy.gov National Building Rating Program Goals * Facilitate cost-effective investment in energy efficiency and reduce energy use in the commercial building sector * Establish a national standard for voluntary commercial building asset rating

227

Innovative Rates Program. Final report  

SciTech Connect (OSTI)

Title II of the Energy Conservation and Production Act (ECPA) as amended by the Public Utility Regulatory Policies Act (PURPA) provided financial assistance to state utility regulatory commissions, nonregulated electric utilities, and the Tennessee Valley Authority through the Innovative Rates Program. The financial assistance was to be used to plan or carry out electric utility regulatory rate reform initiatives relating to innovative rate structures that encourage conservation of energy, electric utility efficiency and reduced costs, and equitable rates to consumers. The Federal and local objectives of the project are described. Activities planned and accomplishments are summarized for the following: project management, data collection, utility bill evaluation, billing enclosure/mailing evaluation, media program evaluation, display evaluation, rate study sessions evaluation, speakers bureau evaluation, and individual customer contacts. A timetable/milestone chart and financial information are included. (MHR)

Not Available

1982-06-21T23:59:59.000Z

228

October 2004 - March 2005 Power Rates (rates/previous)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

4 - March 2005 (CRAC 7 period) "Monthly Adjusted" Wholesale Power Rates Effective October 2004 - March 2005 (CRAC 7 period) (PDF, 3 pages, 13 kb, originally posted at 11 a.m. on...

229

April - September 2002 Power Rates (rates/previous)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

2 (CRAC 2 period) "Monthly Adjusted" Wholesale Power Rates Effective April - September 2002 (CRAC 2 period) (PDF, 9 kb, posted April 1, 2002) Note: The PDF document above provides...

230

October 2002 - March 2003 Power Rates (rates/previous)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

2 - March 2003 (CRAC 3 period) "Monthly Adjusted" Wholesale Power Rates Effective October 2002 - March 2003 (CRAC 3 period) (PDF, 14 kb, posted October 1, 2002) Note: The PDF...

231

April - September 2003 Power Rates (rates/previous)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

3 (CRAC 4 period) "Monthly Adjusted" Wholesale Power Rates Effective April - September 2003 (CRAC 4 period) (PDF, 3 pages, 74 kb, updated April 8, 2003) Note: The PDF document...

232

October 2001 - March 2002 Power Rates (rates/previous)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

1 - March 2002 (CRAC 1 period) "Monthly Adjusted" Wholesale Power Rates Effective October 2001 - March 2002 (CRAC 1 period) (PDF, 6 kb, updated October 3, 2001, posted October 4,...

233

Positron annihilation rates in materials  

Science Journals Connector (OSTI)

The study of positron annihilation rate is one subject of a relatively new method of material structure analysis â?? positron annihilation spectroscopy. Polyethylene Terephthalate (PET) films have been studied by positron annihilation rate measurement. The correlation between annihilation rates and the PET film thickness was established. Similar studies were carried out for aluminium foils and water. The results give information on the probability of positron annihilation per unit of time and per unit of material thickness that is described by an explicit function of the energy transfer model.

Tran Dai Nghiep; Khuong Thanh Tuan; Ngo Danh Du

2007-01-01T23:59:59.000Z

234

Overview of Recent Progres on High Repetition Rate, High Brightness Electron Guns  

E-Print Network [OSTI]

Ceramic DC Electron Gun for the Jefferson Laboratory FEL.ALICE (ERLP) DC Photoinjector Gun Commissioning, Proc. ofa 500-kV Photo- cathode DC Gun for the ERL Light Sources in

Sannibale, F.

2014-01-01T23:59:59.000Z

235

DOE Guidance-Category Rating  

Broader source: Energy.gov (indexed) [DOE]

2010 2010 MEMORANDUM FOR HUMAN RESOURCES DIRECTORS FROM: SARA"iJ. Boku1, DIRECToR OF HUMAN C~TAL MANAGEMENT SUBJECT: GUIDANCE MEMORANDUM #10 CATEGORY RATING The purpose of this memorandum is to establish the Department of Energy's (DOE's) policy for the use of Category Rating. Authorities: Public Law 107-296; Title 5 USC 3319; 5 CFR, Part 337, Subpart C., Presidential Memorandum of May 11, 2010 This guidance is established in accordance with 5 USC 3319, which authorizes Federal Agencies to use alternative rating proced.ures in assessing applicants for employment using category rating and selection procedures, and to ensure consistency in complying with federal regulations contained in the Code of Federal Regulations (CFR), Office of Personnel Management (OPM) and the Department of

236

ARM - Measurement - Radiative heating rate  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

govMeasurementsRadiative heating rate govMeasurementsRadiative heating rate ARM Data Discovery Browse Data Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send Measurement : Radiative heating rate The heating rate due to the divergence of long and shortwave radiative flux. Categories Radiometric, Atmospheric State Instruments The above measurement is considered scientifically relevant for the following instruments. Refer to the datastream (netcdf) file headers of each instrument for a list of all available measurements, including those recorded for diagnostic or quality assurance purposes. External Instruments MOLTS : Model Output Location Time Series Datastreams MOLTS : Model Output Location Time Series Datastreams MOLTSEDASSNDCLASS1 : Model Output Loc. Time Ser. (MOLTS): EDAS

237

OpenEI - electric rates  

Open Energy Info (EERE)

U.S. Electric Utility U.S. Electric Utility Companies and Rates: Look-up by Zipcode (Feb 2011) http://en.openei.org/datasets/node/899 This dataset, compiled by NREL and Ventyx, provides average residential, commercial and industrial electricity rates by zip code for both investor owned utilities (IOU) and non-investor owned utilities. Note: the file includes average rates for each utility, but not the detailed rate structure data found in the database available via the zip-code look-up feature on the OpenEI Utilities page (http://en.openei.org/wiki/Gateway:Utilities). The data was released by NREL/Ventyx in February 2011.

238

High repetition rate fiber lasers  

E-Print Network [OSTI]

This thesis reports work in high repetition rate femtosecond fiber lasers. Driven by the applications including optical arbitrary waveform generation, high speed optical sampling, frequency metrology, and timing and frequency ...

Chen, Jian, Ph. D. Massachusetts Institute of Technology

2009-01-01T23:59:59.000Z

239

Project Definition Rating Index (PDRI)  

Broader source: Energy.gov [DOE]

The Office of Environmental Management (EM) Project Definition Rating Index (EM-PDRI) is a modification of a commercially developed planning tool that has been tested by an EM team specifically for...

240

Electric Rate Alternatives to Cogeneration  

E-Print Network [OSTI]

"ELECTRIC RATE ALTERNATIVES TO COGENERATION" K. R. SANDBERG, JR. INDUSTRIAL ACCOUNTS MANAGER - TEXAS GULF STATES UTILITIES COMPANY BEAUMONT, TEXAS ABSTRACT This paper discusses electric rate slternatives to cogeneration for the industrisl... PERSPECTIVE Gulf States Utilities was incorporated in 1925 and is primarily in the business of generating. transmitting and distributing electricity to 555.000 customers in southeast Texas and south Louisiana. The service area extends 350 miles westward...

Sandberg, K. R. Jr.

Note: This page contains sample records for the topic "kv rating mva" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

KV-tOOJHfe Metallurgy Department  

E-Print Network [OSTI]

.1. Fracture Testing 24 3.2. Fatigue Testing Using Offshore Load Spectrum .. 25 3.3. Brazing and Soldering 25 3 Research on Advanced Ceramic Materials 37 4.8. Developaent and Testing of Oxygen Sensors 38 FUEL ELEMENTS concentrated mainly on nuclear metallurgy to covering a number of different areas within ma- terials science

242

Property:OpenEI/UtilityRate/DemandRateStructure/Tier4Rate | Open Energy  

Open Energy Info (EERE)

Rate" Rate" Showing 13 pages using this property. 4 4b524791-bef2-49b1-850b-458730755203 + 5 +, 6 +, 3 +, ... 4b524791-bef2-49b1-850b-458730755203 + 6 + 4b524791-bef2-49b1-850b-458730755203 + 3 + 4b524791-bef2-49b1-850b-458730755203 + 7 + 4b524791-bef2-49b1-850b-458730755203 + 5 + 4b524791-bef2-49b1-850b-458730755203 + 8 + 4b524791-bef2-49b1-850b-458730755203 + 5 + 4b524791-bef2-49b1-850b-458730755203 + 5 + 4b524791-bef2-49b1-850b-458730755203 + 6 + 4b524791-bef2-49b1-850b-458730755203 + 6 + E E40880ac-c27b-4cbf-a011-b0d7d6e10fe9 + 1 + E40880ac-c27b-4cbf-a011-b0d7d6e10fe9 + 1 + E40880ac-c27b-4cbf-a011-b0d7d6e10fe9 + 1 + Retrieved from "http://en.openei.org/w/index.php?title=Property:OpenEI/UtilityRate/DemandRateStructure/Tier4Rate&oldid=53975

243

Advertising Rates from May 2012  

E-Print Network [OSTI]

Advertising Rates from May 2012 Abitrich INSIDE: NEW LIFTOUT Isausedluxurycar worththerisk? Page8 May 5, 2012 #12;1 MODULE WIDE DRIVE TABLOID ADVERTISING SIZES VALID FROM MAY 2012 2 MODULES WIDE 8 3pm Thursday Display Phoned Bookings and AdOnline Noon Thursday Noon Thursday Display Advertising

Peters, Richard

244

1993 Wholesale Power and Transmission Rate Schedules.  

SciTech Connect (OSTI)

Bonneville Power Administration 1993 Wholesale Power Rate Schedules and General Rate Schedule Provisions and 1993 Transmission Rate Schedules and General Transmission Rate Schedule Provisions, contained herein, were approved on an interim basis effective October 1, 1993. These rate schedules and provisions were approved by the Federal Energy Commission, United States Department of Energy, in September, 1993. These rate schedules and provisions supersede the Administration`s Wholesale Power Rate Schedules and General Rate Schedule Provisions and Transmission Rate Schedules and General Transmission Rate Schedule Provisions effective October 1, 1991.

US Bonneville Power Administration

1993-10-01T23:59:59.000Z

245

2008 WIND TECHNOLOGIES MARKET REPORT  

E-Print Network [OSTI]

five new 345-kV transmission lines, a 345- kV transformer,transmission rates for half of the capacity on two 500-kV transmission linesTransmission filed a transmission proposal at the Colorado public utilities commission for a series of 230-kV and 345-kV lines

Bolinger, Mark

2010-01-01T23:59:59.000Z

246

Federal Energy Management Program: Water Rate Escalations  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Rate Rate Escalations to someone by E-mail Share Federal Energy Management Program: Water Rate Escalations on Facebook Tweet about Federal Energy Management Program: Water Rate Escalations on Twitter Bookmark Federal Energy Management Program: Water Rate Escalations on Google Bookmark Federal Energy Management Program: Water Rate Escalations on Delicious Rank Federal Energy Management Program: Water Rate Escalations on Digg Find More places to share Federal Energy Management Program: Water Rate Escalations on AddThis.com... Sustainable Buildings & Campuses Operations & Maintenance Greenhouse Gases Water Efficiency Basics Federal Requirements Best Management Practices Analysis and Evaluation Water Rate Escalations Evaluation Service Contracts Case Studies Resources

247

conference rates Summer 2014 Policy Statement  

E-Print Network [OSTI]

conference rates Summer 2014 Policy Statement University Catering and Conferences is an auxiliary and organizations holding education- ally related meetings and events on campus. conference rateS (all rates are per occupies, including lounge. Conference staff available for assistance 24 hours per day. Room-only rates

Oregon, University of

248

conference rates Summer 2013 Policy Statement  

E-Print Network [OSTI]

conference rates Summer 2013 Policy Statement University Catering and Conferences is an auxiliary and organizations holding education- ally related meetings and events on campus. conference rateS (all rates are per occupies, including lounge. Conference staff available for assistance 24 hours per day. Room-only rates

Oregon, University of

249

Interviewer's ratings of personality: can these ratings predict job performance?  

E-Print Network [OSTI]

; Goldberg, 1993a; Guastello, 1993; McCrae k Costa, 1985; McCrae & John, 1992) has been about the validity of the five-factor model as a measure of personality; in other words, does the model truly capture all traits of personality? The five-factor model...; Goldberg, 1981; McCrae & Costa, 1987; McCrae & John, 1992; Peabody & Goldberg, 1989). Tupes and Christal (1958, 1992) were the first to look at peer ratings of personality in a variety of samples. Although these samples varied in length and kind...

Archuleta, Kathryn Diane

2012-06-07T23:59:59.000Z

250

P-D Project Rate Adjustment  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Parker-Davis Project Rate Adjustment Data Parker-Davis Project Rate Adjustment Data FY2014 Informal Customer Meeting Notification of Meeting Presentation Preliminary CAS Preliminary Rate Design Preliminary PRS Final Documents Notification of Rates Final CAS Final Rate Design Final PRS FY2013 Informal Customer Meeting Notification of Meeting Presentation Preliminary CAS Preliminary Rate Design Preliminary PRS Supplemental Information Final Documents Notification of Rates Final CAS Final Rate Design Final PRS FY2012 Informal Customer Meeting Notification of Meeting Presentation Preliminary CAS Preliminary Rate Design Preliminary PRS Customer Requested Scenario Final Documents Notification of Rates Final CAS Final Rate Design Final PRS FY2011 Informal Customer Meeting Notification of Meeting Presentation Preliminary CAS Preliminary Rate Design

251

BPA Power Rates (pbl/main)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

recover the costs of generating power and associated expenses. Beginning with the 2010 BPA Rate Case, Power Services and Transmission Services plan to conduct rate cases every...

252

Wholesale Power Rate Schedules | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Services » Rate Schedules » Wholesale Power Rate Schedules Services » Rate Schedules » Wholesale Power Rate Schedules Wholesale Power Rate Schedules October 1, 2012 ALA-1-N Wholesale Power Rate Schedule Area: PowerSouth Energy Cooperative System: Georgia-Alabama-South Carolina October 1, 2012 Duke-1-E Wholesale Power Rate Schedule Area: Duke On-System System: Georgia-Alabama-South Carolina October 1, 2012 Duke-2-E Wholesale Power Rate Schedule Area: Central System: Georgia-Alabama-South Carolina October 1, 2012 Duke-3-E Wholesale Power Rate Schedule Area: None System: Georgia-Alabama-South Carolina October 1, 2012 Duke-4-E Wholesale Power Rate Schedule Area: Duke Self-Schedulers System: Georgia-Alabama-South Carolina October 1, 2012 MISS-1-N Wholesale Power Rate Schedule Area: South Mississippi Electric Power Association

253

Wholesale Power Rate Schedules | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Services » Rate Schedules » Wholesale Power Rate Schedules Services » Rate Schedules » Wholesale Power Rate Schedules Wholesale Power Rate Schedules October 1, 2012 ALA-1-N Wholesale Power Rate Schedule Area: PowerSouth Energy Cooperative System: Georgia-Alabama-South Carolina October 1, 2012 Duke-1-E Wholesale Power Rate Schedule Area: Duke On-System System: Georgia-Alabama-South Carolina October 1, 2012 Duke-2-E Wholesale Power Rate Schedule Area: Central System: Georgia-Alabama-South Carolina October 1, 2012 Duke-3-E Wholesale Power Rate Schedule Area: None System: Georgia-Alabama-South Carolina October 1, 2012 Duke-4-E Wholesale Power Rate Schedule Area: Duke Self-Schedulers System: Georgia-Alabama-South Carolina October 1, 2012 MISS-1-N Wholesale Power Rate Schedule Area: South Mississippi Electric Power Association

254

utility rate | OpenEI Community  

Open Energy Info (EERE)

utility rate utility rate Home Sfomail's picture Submitted by Sfomail(48) Member 17 May, 2013 - 11:14 Utility Rates API Version 2 is Live! API developer OpenEI update utility Utility Companies utility rate Utility Rates version 1 version 2 version 3 web service Smart meter After several months of development and testing, the next generation web service for the utility rate database is finally here! I encourage you to check out the V2 Utility Rates API at http://en.openei.org/services/doc/rest/util_rates Rmckeel's picture Submitted by Rmckeel(297) Contributor 22 June, 2012 - 09:30 Increasing ask query limit developer utility rate An NREL user who is trying to use the utility rate service was having an issue. He writes "I noticed that any rates past 10,000 are not accessible via json. For example, this query only returns two entries:

255

CRSP Transmission Sales Rate History  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Updated: 12/20/2013 Updated: 12/20/2013 CRSP Transmission Sales Rate History Rate Schedule Effective Dates Nonfirm (Mills/kWh) Firm ($/kW-yr.) Firm ($/kW-mo.) None Through 3/83 1.000 $ 6.60 $0.55 SP-FT1 4/83 - 6/86 N.A. $10.27 $0.86 SP-NFT1 4/83 - 6/86 2.000 N.A. SP-FT2 7/86 - 6/89 N.A. $15.94 $1.33 SP-NFT2 7/86 - 7/89 3.100 N.A. SP-FT3 7/89 - 9/92 N.A. $21.72 $1.81 SP-NFT3 8/89 - 3/98 Mutually Agreed N.A. SP-FT4 10/92 - 3/98 N.A. $22.68 $1.89 SP-NFT4 4/98 - 3/03 Mutually Agreed N.A. SP-PTP5 4/98 - 3/99 N.A. $26.70 $2.23 4/99 - 3/00 N.A. $26.19 $2.18 4/00 - 3/01 N.A. $26.14 $2.18 4/01 - 3/02 N.A. $25.63 $2.14 4/02 - 9/02 N.A. $21.33 $1.78 SP-NFT5 10/02 - 9/07 Mutually Agreed N.A. 10/07-9/08 Mutually Agreed N.A. SP-PTP6 10/02 - 9/03 N.A. $24.72 $2.06

256

Combined Retrieval, Microphysical Retrievals and Heating Rates  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

Microphysical retrievals and heating rates from the AMIE/Gan deployment using the PNNL Combined Retrieval.

Feng, Zhe

257

7, 29612989, 2007 Predicting arene rate  

E-Print Network [OSTI]

software or computing power. Measured gas-phase rate coefficients for the reaction of aromatic hydrocarbons

Boyer, Edmond

258

conference rates Summer 2012 Policy Statement  

E-Print Network [OSTI]

conference rates Summer 2012 Policy Statement University Catering and Conferences is an auxiliary holding educationally related meetings and events on campus. conference rateS (all rates are per person lounge. Barnhart Hall service includes private bathrooms/showers. Conference staff available

Oregon, University of

259

U.S. Department of Energy Categorical Exclusion Determination Form  

Broader source: Energy.gov (indexed) [DOE]

Glen Canyon Substation Stage 09- Glen Canyon Substation Stage 09- 50MVA 230/69KV Transformer addition Program or Field Office: DOE/Western/Desert Southwest Region Location(s) (City/County/State): Glen Canyon Substation, Page/Coconino County/Arizona Proposed Action Description: Submit by E-mail Western proposes to conduct electrical maintenance activities within the existing Glen Canyon Substation located at Page, Coconino County, Arizona. The project is on federal (Western-owned) property in Section 19 Township 41 N, Range 8 East, in every quarter sections 24 and 25, Coconino County, AZ, (Gila and Salt River Baseline and Meridian; Figure 1 ). The proposed scope of work includes the following (Figure 2): ·Install one 50MVA 230/69KV transformer to a new storage pad in the upper yard. The new pad will measure 26 feet 6 inches long by 16 feet

260

Property:OpenEI/UtilityRate/EnergyRateStructure/Tier5Rate | Open Energy  

Open Energy Info (EERE)

Rate" Rate" Showing 25 pages using this property. (previous 25) (next 25) 0 00c88d6d-e3b0-4128-ad3e-a93f686cf6e3 + 0.227 + 00c88d6d-e3b0-4128-ad3e-a93f686cf6e3 + 0.227 + 00c88d6d-e3b0-4128-ad3e-a93f686cf6e3 + 0.227 + 019be14c-4635-4529-af90-799cbf5d7865 + 0.0335 + 019be14c-4635-4529-af90-799cbf5d7865 + 0.0335 + 02b061e1-f065-421e-9ebc-76aef4734486 + 0.079 + 02b061e1-f065-421e-9ebc-76aef4734486 + 0.079 + 02fc76fd-35ff-44c3-bc85-1fb1918f125b + 0.0978 + 02fc76fd-35ff-44c3-bc85-1fb1918f125b + 0.0978 + 0402cc99-ab16-40cc-83e7-2c5910a825a1 + 0.061 + 0402cc99-ab16-40cc-83e7-2c5910a825a1 + 0.061 + 041466a9-81ca-4fce-90e3-e718159347a9 + 0.0587 +, 0.044 + 041466a9-81ca-4fce-90e3-e718159347a9 + 0.044 + 041466a9-81ca-4fce-90e3-e718159347a9 + 0.0587 + 047086c9-976d-4a05-90d5-b67afaf60851 + 0.0583 +

Note: This page contains sample records for the topic "kv rating mva" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Wholesale Power Rate Schedules | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Schedules Schedules Wholesale Power Rate Schedules October 1, 2011 CBR-1-H Wholesale Power Rate Schedule Area: Big Rivers and Henderson, KY System: CU October 1, 2011 CSI-1-H Wholesale Power Rate Schedule Area: Southern Illinois System: CU October 1, 2011 CK-1-H Wholesale Power Rate Schedule Area: KU Area System: CU October 1, 2011 CEK-1-H Wholesale Power Rate Schedule Area: East Kentucky System: CU October 1, 2011 CC-1-I Wholesale Power Rate Schedule Area: CP&L Area, Western Division System: CU September 20, 2011 JW-1-J Wholesale Power Rate Schedule Area: Woodruff Preference Customer System: Jim Woodruff September 20, 2011 JW-2-F Wholesale Power Rate Schedule Area: Florida Power Corporation System: Jim Woodruff November 17, 2010 AP-1-B Wholesale Power Rate Schedule Area: American Electric Power

262

1996 Wholesale Power and Transmission Rate Schedules.  

SciTech Connect (OSTI)

Bonneville Power Administration`s (BPA) 1996 Wholesale Power Rate Schedules, 1996 Ancillary Products and Services Rate Schedule, 1996 Transmission Rate Schedules, and General Rate Schedule Provisions, contained herein, were approved on an interim basis effective October 1, 1996. These rate schedules and provisions were approved by the Federal Energy Regulatory Commission (FERC), United States Department of Energy, in September 1996 (Docket Nos EF96-2011-000 and EF96f-2021-000). These rate schedules and General Rate Schedule Provisions were approved on a final basis by the FERC July 30, 1997, in Dept. of Energy--Bonneville Power Administration, Docket Nos. EF96-2011-000 and EF96-2021-000. Except as noted elsewhere, these 1996 rate schedules and provisions supersede BPA`s Wholesale Power Rate Schedules and General Rate Schedule Provisions, and Transmission Rate Schedules and General Transmission Rate Schedule Provisions, effective October 1, 1995. These rate schedules and general rate schedule provisions include all errata.

United States. Bonneville Power Administration.

1996-10-01T23:59:59.000Z

263

TWRS privatization phase 1 electrical power system  

SciTech Connect (OSTI)

This document includes Conceptual Design Report (CDR) for a new 11 km (7 miles) 230 kV transmission line and a new 40 MVA substation (A6) which will be located east of Grout Facility in 200E Area tank farm. This substation will provide electrical power up to 20 MW each for two private contractor facilities for immobilization and disposal of low activity waste (LAW).

Singh, G.

1997-05-30T23:59:59.000Z

264

Field test of liquid nitrogen cooled cryogenic power cable  

Science Journals Connector (OSTI)

A liquid nitrogen cooled cryogenic cable, 66 kV, 100 MVA, 30 m was constructed and tested with loads simulating actual operating loads from October 1970 to December 1971. The successful operation of the cable makes us hopeful it can be used for large capacity transmission. Our test line is composed of aluminium stranded hollow conductor, liquid-nitrogen impregnated polyethylene paper electrical insulation, and polyurethane foam thermal insulation.

H. Nagano; M. Fukasawa; S. Kuma; K. Sugiyama

1973-01-01T23:59:59.000Z

265

ENVIRONMENTAL REVIEW FOR CATEGORICAL EXCLUSION DETERMINATION  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

KV1A Replacement KV1A Replacement Laramie County, Wyoming A. Brief Description of Proposal: Western Area Power Administration (Western) will replace transformer KV1A at the Archer Substation. The substation is located in township 14 North, range 65 West, Section 27 of Laramie County, Wyoming, at longitude 104° 38' 57" West, latitude 41 o 8' 43" North. The existing 220/115/13.8-kV, 166.7 MVA transformer KV1A is composed of three single phase 220/115-kV 55.5 MV A transformers. The A-phase (KV1A3) failed, but with the use of the mobile transformer KV1A still operates at a reduced capacity of 100 MV A. Western will replace this configuration with a single multi-phase unit. The new unit will be a 3-phase 230/115/13.8-kV 200 MV A transformer which will be installed in the same general location as the

266

ENVIRONMENTAL REVIEW FOR CATEGORICAL EXCLUSION DETERMINATION  

Broader source: Energy.gov (indexed) [DOE]

KV1A Replacement KV1A Replacement Laramie County, Wyoming A. Brief Description of Proposal: Western Area Power Administration (Western) will replace transformer KV1A at the Archer Substation. The substation is located in township 14 North, range 65 West, Section 27 of Laramie County, Wyoming, at longitude 104° 38' 57" West, latitude 41 o 8' 43" North. The existing 220/115/13.8-kV, 166.7 MVA transformer KV1A is composed of three single phase 220/115-kV 55.5 MV A transformers. The A-phase (KV1A3) failed, but with the use of the mobile transformer KV1A still operates at a reduced capacity of 100 MV A. Western will replace this configuration with a single multi-phase unit. The new unit will be a 3-phase 230/115/13.8-kV 200 MV A transformer which will be installed in the same general location as the

267

OpenEI Community - utility rate  

Open Energy Info (EERE)

Rates API Rates API Version 2 is Live! http://en.openei.org/community/blog/utility-rates-api-version-2-live Smart meterAfter several months of development and testing, the next generation web service for the utility rate database is finally here! I encourage you to check out the V2 Utility Rates API at rates">http://en.openei.org/services/doc/rest/util_ratesrates-api-version-2-live" target="_blank">read more

268

Utility Rate | OpenEI Community  

Open Energy Info (EERE)

Utility Rate Utility Rate Home > Utility Rate > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: API Type Term Title Author Replies Last Post sort icon Blog entry API The utility rate database version 1 API is now deprecated Rmckeel 6 Sep 2013 - 14:00 Blog entry API Lighting Electricity Rates on OpenEI Sfomail 31 May 2013 - 12:04 Blog entry API Utility Rates API Version 2 is Live! Sfomail 17 May 2013 - 11:14 Groups Menu You must login in order to post into this group. Recent content There is currently no way to s... ranking of utilities by demand charge? FYI, OpenEI now accommodates t... Very useful information. Thank... The utility rate database version 1 API is now deprecated more Group members (28) Managers: Dloomis

269

Energy Efficiency Interest Rate Reduction Program  

Broader source: Energy.gov [DOE]

The Alaska Housing Finance Corporation (AHFC) offers interest rate reductions to home buyers purchasing new and existing homes with 5 Star and 5 Star Plus energy ratings. All homes constructed on...

270

Articulatory Rate, Stuttering and Speech Motor Control  

Science Journals Connector (OSTI)

There is a close relation between the rate of speech and stuttering. Struggle behaviors, abnormally repeated and prolonged sounds, and other stuttering behaviors naturally slow the rate of speech. Correlations be...

Barbara J. Amster; C. Woodruff Starkweather

1987-01-01T23:59:59.000Z

271

Stocking Rate: The Key Grazing Management Decision  

E-Print Network [OSTI]

Stocking rate is the most important grazing management decision a rancher makes. This publication covers all the factors involved in determining an appropriate stocking rate, including rainfall and forage production, range condition, and the forage...

Lyons, Robert K.; Machen, Richard V.

2001-07-19T23:59:59.000Z

272

Low Bit Rate Digital Coding of Audio  

Science Journals Connector (OSTI)

Low bit rate digital coding, also known as perceptual coding, makes use of several psychoacoustical masking phenomena to reduce the bit rate required to transmit digital audio. The need for such te...

John M. Eargle

1996-01-01T23:59:59.000Z

273

Commercial Building Energy Asset Rating Workshop  

Broader source: Energy.gov [DOE]

DOE commercial building energy asset rating program information presented to stakeholders at the workshop held in Washington, DC, December 2011

274

Spontaneous Emission Rate Enhancement Using Optical Antennas  

E-Print Network [OSTI]

of  Spontaneous  Emission  in  a  Semiconductor  nanoLED,”  emission  rate  enhancement  using  the  Fluorescent  Emission  by  Lattice   Resonances  in  

Kumar, Nikhil

2013-01-01T23:59:59.000Z

275

POLICY GUIDANCE MEMORANDUM #10 Category Rating  

Broader source: Energy.gov [DOE]

This memorandum is to establish the Department of Energy's (DOE's) policy for the use of Category Rating.

276

Variable accretion rates and fluffy first stars  

Science Journals Connector (OSTI)

......high accretion rate ( Mo yr1, M *= 10.35 Mo) as it passes through the spiral...45 Mo) as it passes through a less...The accretion rate of the orbiting...understand the physics of such an encounter...where the sinks pass within each others...high accretion rates. They show that......

Rowan J. Smith; Takashi Hosokawa; Kazuyuki Omukai; Simon C. O. Glover; Ralf S. Klessen

2012-07-21T23:59:59.000Z

277

Definition: Emergency Rating | Open Energy Information  

Open Energy Info (EERE)

Emergency Rating Emergency Rating Jump to: navigation, search Dictionary.png Emergency Rating The rating as defined by the equipment owner that specifies the level of electrical loading or output, usually expressed in megawatts (MW) or Mvar or other appropriate units, that a system, facility, or element can support, produce, or withstand for a finite period. The rating assumes acceptable loss of equipment life or other physical or safety limitations for the equipment involved.[1] Related Terms rating References ↑ Glossary of Terms Used in Reliability Standards An LikeLike UnlikeLike You like this.Sign Up to see what your friends like. inline Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Emergency_Rating&oldid=480317" Categories:

278

Water Rate Escalations | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Rate Escalations Rate Escalations Water Rate Escalations October 8, 2013 - 9:55am Addthis Federal agencies need accurate water cost escalation rates to perform life cycle cost analyses for water efficiency projects to meet Executive Order 13514 and Energy Independence and Security Act of 2007 requirements. To estimate long-term escalation rates of potable water, Pacific Northwest National Laboratory (PNNL) conducted an analysis. Using the trends from this study, Federal facility managers can select escalation rates from studied cities with similar circumstances to their facility locations such as U.S. region, water source, or drought tendencies. Also they can make more informed choices on possible water escalation rates that can be used in economic analysis of water efficiency projects.

279

Utility Rates | OpenEI Community  

Open Energy Info (EERE)

Utility Rates Utility Rates Home Rmckeel's picture Submitted by Rmckeel(297) Contributor 6 September, 2013 - 14:00 The utility rate database version 1 API is now deprecated API Utility Rates There comes a time in every API version's lifecycle when it needs to be deprecated. OpenEI's utility rate database version 1 API has been in use since the inception of the database in 2010. As Illinois State University has taken a commanding lead of the project and its data curation, we have updated the schema and API to version 2 to present a richer spectrum of utility rate data. Rmckeel's picture Submitted by Rmckeel(297) Contributor 11 June, 2013 - 09:33 Tip for working with approvals on OpenEI EZFeed Utility Rates The "ApprovedRevs" extension is the feature on OpenEI that allows

280

Definition: Penetration Rate | Open Energy Information  

Open Energy Info (EERE)

Definition Definition Edit with form History Facebook icon Twitter icon » Definition: Penetration Rate Jump to: navigation, search Dictionary.png Penetration Rate The Rate of penetration, abbreviated as ROP as used in the drilling industry, is the speed at which a drill bit breaks the rock under it to deepen the borehole. It is normally measured in feet per minute or meters per hour, but sometimes it is expressed in minutes per foot.[1] View on Wikipedia Wikipedia Definition The Rate of penetration, abbreviated as ROP as used in the drilling industry, is the speed at which a drill bit breaks the rock under it to deepen the borehole. Also known as penetration rate or drill rate. It is normally measured in feet per minute or meters per hour, but sometimes it is expressed in minutes per foot.

Note: This page contains sample records for the topic "kv rating mva" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Utility Rate | OpenEI Community  

Open Energy Info (EERE)

Utility Rate Utility Rate Home > Utility Rate > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: developer Type Term Title Author Replies Last Post sort icon Blog entry developer Utility Rates API Version 2 is Live! Sfomail 17 May 2013 - 11:14 Discussion developer Utility rate change propagation is now much faster Rmckeel 1 21 Mar 2013 - 09:11 Blog entry developer OpenEI maintenance March 8-9, 2013 Rmckeel 8 Mar 2013 - 14:23 Blog entry developer Semantic Mediawiki Semantic Forms update Rmckeel 22 Oct 2012 - 07:23 Discussion developer Increasing ask query limit Rmckeel 1 28 Jun 2012 - 14:35 Groups Menu You must login in order to post into this group. Recent content FYI, OpenEI now accommodates t... Very useful information. Thank...

282

Rate-Making Policy | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Rate-Making Policy Rate-Making Policy Rate-Making Policy < Back Eligibility Investor-Owned Utility Rural Electric Cooperative Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info Start Date 2005 State Wisconsin Program Type Generating Facility Rate-Making Provider Public Service Commission of Wisconsin WI Act 7 states that, when proposing the purchase or construction of an electric generating facility, a utility may "apply to the [WI Public Service Commission] for an order specifying in advance the rate-making principles" that the Public Service Commission will use for "future rate-making proceedings." The Nuclear Energy Institute highlights that "There is no restriction on

283

Definition: Dynamic Capability Rating | Open Energy Information  

Open Energy Info (EERE)

Capability Rating Capability Rating Jump to: navigation, search Dictionary.png Dynamic Capability Rating Dynamic capability rating can be achieved through real-time determination of an element's (e.g., line, transformer etc.) ability to carry load based on electrical and environmental conditions.[1] Related Terms rating References ↑ SmartGrid.gov 'Description of Functions' An LikeLike UnlikeLike You like this.Sign Up to see what your friends like. inline Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Dynamic_Capability_Rating&oldid=506158" Categories: Definitions ISGAN Definitions What links here Related changes Special pages Printable version Permanent link Browse properties 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load)

284

THE EXCHANGE RATE-INVESTMENT NEXUS AND EXCHANGE RATE INSTABILITY: ANOTHER REASON FOR `FEAR OF FLOATING'  

E-Print Network [OSTI]

THE EXCHANGE RATE-INVESTMENT NEXUS AND EXCHANGE RATE INSTABILITY: ANOTHER REASON FOR `FEAR repercussion comes through the reaction of firms to changed asset prices and the firms' decisions to invest: F31, F32 *Corresponding author 1 #12;THE EXCHANGE RATE-INVESTMENT NEXUS AND EXCHANGE RATE

Ahmad, Sajjad

285

HEART RATE AS A MONITOR FOR METABOLIC RATE IN CAPTIVE JUVENILE STELLER SEA LIONS (EUMETOPIAS JUBATUS)  

E-Print Network [OSTI]

HEART RATE AS A MONITOR FOR METABOLIC RATE IN CAPTIVE JUVENILE STELLER SEA LIONS (EUMETOPIAS COLUMBIA 0Jan M. Mcl'hee, 2001 #12;ABSTRACT The potential use of heart rate to monitor energy expenditure a relationship exists between heart rate @I) and oxygen consumption ( ~ 0 ~ )in captive sea lions while swimming

286

Utility Rate Discounts | Open Energy Information  

Open Energy Info (EERE)

Discounts Discounts Jump to: navigation, search A few electric utilities offer rate discounts to encourage residential energy efficiency. For homes that meet certain energy efficiency criteria, such as those established by the federal Energy Star program, the owner or tenant is awarded a percentage discount on each monthÂ’s electric bill. [1] Contents 1 Utility Rate Discount Incentives 2 References Utility Rate Discount Incentives CSV (rows 1 - 14) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active Cleco Power - Power Miser New Home Program (Louisiana) Utility Rate Discount Louisiana Residential Building Insulation Central Air conditioners Clothes Washers Comprehensive Measures/Whole Building Doors Duct/Air sealing Furnaces Heat pumps

287

Cervical Cancer Rates in Allegheny County Communities.  

E-Print Network [OSTI]

??Aggregated cervical cancer rates for the 21 year period 1985 through 2005 were age-adjusted and standardized for each neighborhood and municipality in Allegheny County, Pennsylvania.… (more)

Assenat, Mary Margaret

2012-01-01T23:59:59.000Z

288

Photovoltaic Degradation Rates -- An Analytical Review  

SciTech Connect (OSTI)

As photovoltaic penetration of the power grid increases, accurate predictions of return on investment require accurate prediction of decreased power output over time. Degradation rates must be known in order to predict power delivery. This article reviews degradation rates of flat-plate terrestrial modules and systems reported in published literature from field testing throughout the last 40 years. Nearly 2000 degradation rates, measured on individual modules or entire systems, have been assembled from the literature, showing a median value of 0.5%/year. The review consists of three parts: a brief historical outline, an analytical summary of degradation rates, and a detailed bibliography partitioned by technology.

Jordan, D. C.; Kurtz, S. R.

2012-06-01T23:59:59.000Z

289

Examiner Characteristics and the Patent Grant Rate  

E-Print Network [OSTI]

Characteristics and the Patent Grant Rate * Mark Lemley †USPTO: whether or not to grant a patent. We ?nd that moreart, are more likely to grant patent applications. These

Lemley, Mark A.

2009-01-01T23:59:59.000Z

290

BPA issues final decision on oversupply rate  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

issues-final-decision-on-oversupply-rate Sign In About | Careers | Contact | Investors | bpa.gov Search News & Us Expand News & Us Projects & Initiatives Expand Projects &...

291

Adaptive Filtering for Heart Rate Signals.  

E-Print Network [OSTI]

?? This work focused on the effects of suppressing the motion artifact of wrist photoplethysmographic heart rate signals. Monitoring of the heart can offer important… (more)

Jaafari, Samira

2014-01-01T23:59:59.000Z

292

Method of controlling fusion reaction rates  

DOE Patents [OSTI]

This invention relates to a method of controlling the reaction rates in a nuclear fusion reactor; and more particularly, to the use of polarized nuclear fuel.

Kulsrud, R.M.; Furth, H.P.; Valeo, E.J.; Goldhaber, M.

1983-05-09T23:59:59.000Z

293

Single Assessment Pass Rate South Carolina  

E-Print Network [OSTI]

Single Assessment Pass Rate South Carolina Academic Year 2004 - 2005 ETS Type of Assessment Test in Cohort 2,218 in Cohort #12;Single Assessment Pass Rate South Carolina Academic Year 2004 - 2005 ETS Type, Part 0063 Middle School Mathematics 0069 Chemistry, Physics and General Science 0070 Social Studies

Kasman, Alex

294

8, 67936824, 2008 dispersion rates in  

E-Print Network [OSTI]

patterns, it is shown that initial buoyancy fluxes at ship stack have minor effect on plume dilution rate modeling and measurement (remote or "in-situ") studies of ship exhaust25 effects must dealACPD 8, 6793­6824, 2008 Ship plume dispersion rates in convective BL F. Chosson et al. Title Page

Paris-Sud XI, Université de

295

Cadmium Biosorption Rate in Protonated Sargassum Biomass  

E-Print Network [OSTI]

Cadmium Biosorption Rate in Protonated Sargassum Biomass J I N B A I Y A N G A N D B O H U M I L V Sargassum fluitans biomass was accompanied by the release of hydrogen protons from the biomass. The uptake the overall biosorption rate of cadmium ions in flat seaweed biomass particles. The overall biosorption

Volesky, Bohumil

296

False Discovery Rates John D. Storey  

E-Print Network [OSTI]

positives. The false discovery rate is designed to quantify this type of trade-off, making it particularly Hypothesis Testing In hypothesis testing, statistical significance is typically based on calculations involving p-values and Type I error rates. A p-value calculated from a single statistical hypothesis test

Storey, John D.

297

Resonances and the thermonuclear reaction rate  

E-Print Network [OSTI]

We present an approximate analytic expression for thermonuclear reaction rate of charged particles when the cross section contains a single narrow or wide resonance described by a Breit-Wigner shape. The resulting expression is uniformly valid as the effective energy and resonance energy coalesce. We use our expressions to calculate the reaction rate for $^{12}$C(p,$\\gamma$)$^{13}$N.

M. S. Hussein; M. Ueda; A. J. Sargeant; M. P. Pato

2003-07-21T23:59:59.000Z

298

Method of controlling fusion reaction rates  

DOE Patents [OSTI]

A method of controlling the reaction rates of the fuel atoms in a fusion reactor comprises the step of polarizing the nuclei of the fuel atoms in a particular direction relative to the plasma confining magnetic field. Fusion reaction rates can be increased or decreased, and the direction of emission of the reaction products can be controlled, depending on the choice of polarization direction.

Kulsrud, Russell M. (Princeton, NJ); Furth, Harold P. (Princeton, NJ); Valeo, Ernest J. (Princeton Junction, NJ); Goldhaber, Maurice (Bayport, NY)

1988-01-01T23:59:59.000Z

299

Definition: Equipment Rating | Open Energy Information  

Open Energy Info (EERE)

Rating Rating Jump to: navigation, search Dictionary.png Equipment Rating The maximum and minimum voltage, current, frequency, real and reactive power flows on individual equipment under steady state, short-circuit and transient conditions, as permitted or assigned by the equipment owner.[1] Also Known As Standard current ratings Related Terms reactive power, smart grid References ↑ Glossary of Terms Used in Reliability Standards An i LikeLike UnlikeLike You like this.Sign Up to see what your friends like. nline Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Equipment_Rating&oldid=502535" Categories: Definitions ISGAN Definitions What links here Related changes Special pages Printable version Permanent link Browse properties

300

OpenEI Community - Utility Rates  

Open Energy Info (EERE)

The utility rate The utility rate database version 1 API is now deprecated http://en.openei.org/community/blog/utility-rate-database-version-1-api-now-deprecated There comes a time in every API version's lifecycle when it needs to be deprecated.OpenEI's utility rate database version 1 API has been in use since the inception of the database in 2010.  As Illinois State University has taken a commanding lead of the project and its data curation, we have updated the schema and API to version 2 to present a richer spectrum of utility rate data.

Note: This page contains sample records for the topic "kv rating mva" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Utility Rate | OpenEI Community  

Open Energy Info (EERE)

Utility Rate Utility Rate Home > Utility Rate > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: challenge Type Term Title Author Replies Last Post sort icon Discussion challenge 2013 Civic Hacking Day Ideas Rmckeel 1 22 May 2013 - 08:23 Groups Menu You must login in order to post into this group. Recent content There is currently no way to s... ranking of utilities by demand charge? FYI, OpenEI now accommodates t... Very useful information. Thank... The utility rate database version 1 API is now deprecated more Group members (28) Managers: Dloomis Rmckeel Sfomail Recent members: MSiira Apin101 Lissacoffey Denizurla Bazouing Gdavis Shehant Anapettirossi Abkatzman BijouLulla Vbugnion Marklane Cbonsig Verdel3c Wisconsin Weatherall Windows Payne

302

Method for Determining Solids Circulation Rate  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Determining Solids Circulation Rate Determining Solids Circulation Rate Contact NETL Technology Transfer Group techtransfer@netl.doe.gov May 2012 Opportunity Research is currently active on the patented technology "Method for Determining Solids Circulation Rate." The technology is available for licensing and/or further collaborative research from the U.S. Department of Energy's National Energy Technology Laboratory. Overview This invention provides a method to measure the rate of solids circulation, particularly in those applications where the solids are recycled back to pro- cesses for further use. The applications include processes such as circulating fluidized bed gasifiers and combustors, as well as chemical looping. In the above applications, determining solids circulation rates is needed to

303

gas rates | OpenEI Community  

Open Energy Info (EERE)

gas rates gas rates Home > Groups > Utility Rate Are there Gas Utility Rates available in OpenEI? Submitted by Nlong on 11 July, 2012 - 11:41 1 answer Points: 1 Hi, OpenEI doesn't have NG utility rates as far as I'm aware. That may be a dataset that is added in the future. You can access natural gas prices by utility and sector by downloading the EIA-176 form from the Energy Information Administration. I've included some links to help you find your way. http://205.254.135.7/survey/form/eia_176/efs176.cfm http://www.eia.gov/oil_gas/natural_gas/applications/eia176query_historical.html -Sfomail Sfomail on 12 July, 2012 - 12:04 Groups Menu You must login in order to post into this group. Recent content There is currently no way to s... ranking of utilities by demand charge?

304

Utility Rate | OpenEI Community  

Open Energy Info (EERE)

Utility Rate Utility Rate Home > Features > Groups Content Group Activity By term Q & A Feeds Content type Blog entry Discussion Document Event Poll Question Keywords Author Apply Ewilson FYI, OpenEI now accommodates t... Posted by: Ewilson 20 Sep 2013 - 11:58 99thin Very useful information. Thank... Posted by: 99thin 9 Sep 2013 - 00:19 Rmckeel The utility rate database version 1 API is now deprecated Posted by: Rmckeel 6 Sep 2013 - 14:00 There comes a time in every API version's lifecycle when it needs to be deprecated. OpenEI's utility rate database version 1 API has been in use since the inception of the database in 2010. As... Tags: API, Utility Rates NickL Glad I could help get you on t... Posted by: NickL 4 Sep 2013 - 07:41 Glad I could help get you on the right track Myles. There is not as simple

305

International Rates | OpenEI Community  

Open Energy Info (EERE)

International Rates International Rates Home > Groups > Utility Rate Nsbowde's picture Submitted by Nsbowde(12) Member 10 July, 2012 - 11:27 Per the town hall discussion yestereday, I have a link to a tariff database assembled by the Energy Regulators Regional Association. There is no free access and reproduction of the information without ERRA consent is prohibited, but nonetheless here it is. I have some friends in ERRA, so maybe future collaboration could be possible. http://www.erranet.org/Products/TariffDatabase Nick Groups: Utility Rate Login to post comments Nsbowde's blog Comments Rmckeel Rmckeel1 year 26 weeks ago International rates Thanks for the info, Nick! On a side note, when we move our blog over to OpenEI communities, content like this blog entry will be more visible on

306

Utility Rate | OpenEI Community  

Open Energy Info (EERE)

Utility Rate Utility Rate Home > Utility Rate > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: American Clean Skies Foundation Type Term Title Author Replies Last Post sort icon Blog entry American Clean Skies Foundation Nominations open for $250,000 Multimedia Clean Energy prizes Graham7781 2 Oct 2012 - 13:01 Groups Menu You must login in order to post into this group. Recent content There is currently no way to s... ranking of utilities by demand charge? FYI, OpenEI now accommodates t... Very useful information. Thank... The utility rate database version 1 API is now deprecated more Group members (28) Managers: Dloomis Rmckeel Sfomail Recent members: MSiira Apin101 Lissacoffey Denizurla Bazouing Gdavis Shehant Anapettirossi Abkatzman

307

THE NOVA RATE IN NGC 2403  

SciTech Connect (OSTI)

A multi-epoch H{alpha} survey of the late-type spiral galaxy NGC 2403 has been completed in order to determine its nova rate. A total of nine nova candidates were discovered in 48 nights of observation with two different telescopes over the period from 2001 February to 2012 April. After making corrections for temporal coverage and spatial completeness, a nova rate of 2.0{sup +0.5} {sub -0.3} yr{sup -1} was determined. This rate corresponds to a luminosity-specific nova rate of 2.5 {+-} 0.7 novae per year per 10{sup 10} L {sub Sun ,K}. This value is consistent with that of the similar Hubble-type galaxy, M33, and is typical of those of other galaxies with measured nova rates, which range from 1 to 3 novae per year per 10{sup 10} L {sub Sun ,K}.

Franck, J. R.; Shafter, A. W. [Department of Astronomy, San Diego State University, San Diego, CA 92182 (United States); Hornoch, K. [Astronomical Institute, Academy of Sciences, CZ-251 65 Ondrejov (Czech Republic); Misselt, K. A. [Steward Observatory, University of Arizona, Tucson, AZ 85721 (United States)

2012-11-20T23:59:59.000Z

308

Utility Rate | OpenEI Community  

Open Energy Info (EERE)

Utility Rate Utility Rate Home > Utility Rate > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: data Type Term Title Author Replies Last Post sort icon Blog entry data Commercial and Residential Hourly Load Data Now Available on OpenEI! Sfomail 17 May 2013 - 12:03 Blog entry data IRENA launches global atlas of renewable energy potential Graham7781 11 Feb 2013 - 15:18 Groups Menu You must login in order to post into this group. Recent content FYI, OpenEI now accommodates t... Very useful information. Thank... The utility rate database version 1 API is now deprecated Glad I could help get you on t... Nick, Thanks very much! That... more Group members (25) Managers: Dloomis Rmckeel Sfomail Recent members: Denizurla Bazouing Gdavis

309

Selective Induction of Host Genes by MVA-B, a Candidate Vaccine against HIV/AIDS  

Science Journals Connector (OSTI)

...Bennink, V. M. Hirsch, S. Goldstein, W. R. Elkins, T. R. Fuerst, J. D. Lifson, M. Piatak, N. P. Restifo, W. Overwijk, R. Chamberlain, S. A. Rosenberg, and G. Sutter. 1996. Host range restricted, non-replicating vaccinia virus vectors...

Susana Guerra; José Manuel González; Núria Climent; Hugh Reyburn; Luis A. López-Fernández; José L. Nájera; Carmen E. Gómez; Felipe García; José M. Gatell; Teresa Gallart; Mariano Esteban

2010-06-09T23:59:59.000Z

310

Rate Schedule CV-RFS4  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

RFS4 RFS4 (Supersedes Schedule CV-RFS3) UNITED STATES DEPARTMENT OF ENERGY WESTERN AREA POWER ADMINISTRATION CENTRAL VALLEY PROJECT SCHEDULE OF RATE FOR REGULATION AND FREQUENCY RESPONSE SERVICE Effective: October 1, 2011, through September 30, 2016. Available: Within the marketing area served by the Western Area Power Administration (Western), Sierra Nevada Customer Service Region. Applicable: To customers receiving Regulation and Frequency Response Service (regulation). Character and Conditions of Service: Regulation is necessary to provide for the continuous balancing of resources and interchange with load and for maintaining scheduled interconnection frequency at 60-cycles per second. Formula Rate: The formula rate for regulation includes three components:

311

Measuring Degradation Rates Without Irradiance Data  

SciTech Connect (OSTI)

A method to report PV system degradation rates without using irradiance data is demonstrated. First, a set of relative degradation rates are determined by comparing daily AC final yields from a group of PV systems relative to the average final yield of all the PV systems. Then, the difference between relative and absolute degradation rates is found from a statistical analysis. This approach is verified by comparing to methods that utilize irradiance data. This approach is significant because PV systems are often deployed without irradiance sensors, so the analysis method described here may enable measurements of degradation using data that were previously thought to be unsuitable for degradation studies.

Pulver, S.; Cormode, D.; Cronin, A.; Jordan, D.; Kurtz, S.; Smith, R.

2011-02-01T23:59:59.000Z

312

Error analysis for resonant thermonuclear reaction rates  

Science Journals Connector (OSTI)

A detailed presentation is given of estimating uncertainties in thermonuclear reaction rates for stellar nucleosynthesis involving narrow resonances, starting from random errors in measured or calculated resonance and nuclear level properties. Special attention is given to statistical matters such as probability distributions, error propagation, and correlations between errors. Interpretation of resulting uncertainties in reaction rates and the distinction between symmetric and asymmetric errors are also discussed. Computing reaction rate uncertainties is described. We give examples from explosive nucleosynthesis by hydrogen burning on light nuclei.

William J. Thompson; C. Iliadis

1999-01-01T23:59:59.000Z

313

WP-96/TR-96 & TC-96 Power and Transmission Rate Case (rates/ratecases...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

(PFR) Firstgov WP-96TR-96 & TC-96 Power and Transmission Rate Case Index: Final 1996 Wholesale Power and Transmission Rates Proposal (WP-96TR-96) Administrator's Record Of...

314

EPA Notice of Availability of the Federal Draft Environmental Impact Statement and State of Montana Supplemental Draft Environmental Impact Statement for the Montana Alberta Tie Ltd. (MATL) 230-kV Transmission Line (02/08)  

Broader source: Energy.gov (indexed) [DOE]

9 Federal Register 9 Federal Register / Vol. 73, No. 32 / Friday, February 15, 2008 / Notices counties, UT, Montrose County, CO, and Uinta County, WY. Summary: EPA has environmental concerns about potential water quality impacts and recommends that the final EIS evaluate and compare the environmental impacts by alternative, of removing interim protections from the 86 eligible stream segments. Rating EC1. Final EISs EIS No. 20070530, ERP No. F-COE- E39071-00, Wolf Creek Dam/Lake Cumberland Project, Emergency Measures in Response to Seepage, Mississippi River, South Central Kentucky and Central Tennessee. Summary: EPA continues to have environmental concerns about water quantity and water quality impacts. EIS No. 20070556, ERP No. F-NGB- E11062-MS, Camp Shelby Joint Force

315

Utility Rate | OpenEI Community  

Open Energy Info (EERE)

Utility Rate Utility Rate Home > Utility Rate > Posts by term Content Group Activity By term Q & A Feeds American Clean Skies Foundation (1) API (3) Apps (1) bug (1) building load (1) building load data (1) challenge (1) clean energy (1) commercial load (1) data (2) dataset (1) datasets (1) developer (5) DOE (1) EIA (1) electric load data (1) energy efficiency (1) Energy Visions Prize (1) EZFeed (1) FOA (1) funding (1) Global Atlas (1) hackathon (1) Illinois State University (1) Incentives and Policies (1) 1 2 3 next › last » Groups Menu You must login in order to post into this group. Recent content There is currently no way to s... ranking of utilities by demand charge? FYI, OpenEI now accommodates t... Very useful information. Thank... The utility rate database version 1 API is now deprecated

316

On-site Housing Rates | Staff Services  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Rates Rates Effective February 1, 2013 Rates for Occupancy < 30-Days Guest House* Single/Double: US $105.00/day Housekeeping service is provided on all working days. *Alternatives to the Guest House - When family-type accommodations are assigned to temporary or transient personnel, Guest House rates as set forth above will apply. The total will not exceed one months' rent for a unit occupied for 30 days or less. When such assignment is necessary due to lack of adequate Guest House accommodations, housekeeping service is provided on working days; for reservations staying seven days or less. Residence Houses Curie House: US $42.00/day Cavendish House: US $42.00/day Compton House: US $42.00/day Housekeeping service for all residence houses are provided three times per

317

Definition: Rated power | Open Energy Information  

Open Energy Info (EERE)

Definition Definition Edit with form History Facebook icon Twitter icon » Definition: Rated power Jump to: navigation, search Dictionary.png Rated power The power output of a device under specific or nominal operating conditions[1] View on Wikipedia Wikipedia Definition In electrical and electronic engineering, the power rating of a device is a guideline set by the manufacturer as a maximum power to be used with that device. This limit is usually set somewhat lower than the level where the device will be damaged, to allow a margin of safety. In devices which primarily dissipate electric power or convert it into mechanical power, such as resistors, electric motors, and speakers, the power rating given is usually the maximum power that can be safely dissipated by the

318

Utility Rate | OpenEI Community  

Open Energy Info (EERE)

Utility Rate Utility Rate Home > Groups > Groups > Utility Rate Content Group Activity By term Q & A Feeds There are no feeds from external sites for this group. Groups Menu You must login in order to post into this group. Groups Menu You must login in order to post into this group. Group members (28) Managers: Dloomis Rmckeel Sfomail Recent members: MSiira Apin101 Lissacoffey Denizurla Bazouing Gdavis Shehant Anapettirossi Abkatzman BijouLulla Vbugnion Marklane Cbonsig Verdel3c Wisconsin Weatherall Windows Payne Nlong Wzeng Recent content There is currently no way to s... ranking of utilities by demand charge? FYI, OpenEI now accommodates t... Very useful information. Thank... The utility rate database version 1 API is now deprecated more Group members (28) Managers: Dloomis Rmckeel Sfomail

319

NREL: Photovoltaics Research - Photovoltaic Energy Ratings Methods  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Photovoltaic Energy Ratings Methods Validation Photovoltaic Energy Ratings Methods Validation The Photovoltaic (PV) Engineering group at NREL validates energy ratings methods by standards committees to establish an energy rating methodology. We are evaluating techniques to account for the impact on PV performance from variations in the spectral distribution of solar radiation. Two types of methods were evaluated for correcting the short-circuit current of PV modules for variations in the solar spectrum under clear skies: (1) empirical relationships based on air mass, and (2) use of spectral irradiance models and PV module spectral response data. Methods of the first type were the Sandia National Laboratories absolute air-mass function, or f(AMa), and the CREST air-mass function, or f(AM). The second

320

Uncertainty Analysis for Photovoltaic Degradation Rates (Poster)  

SciTech Connect (OSTI)

Dependable and predictable energy production is the key to the long-term success of the PV industry. PV systems show over the lifetime of their exposure a gradual decline that depends on many different factors such as module technology, module type, mounting configuration, climate etc. When degradation rates are determined from continuous data the statistical uncertainty is easily calculated from the regression coefficients. However, total uncertainty that includes measurement uncertainty and instrumentation drift is far more difficult to determine. A Monte Carlo simulation approach was chosen to investigate a comprehensive uncertainty analysis. The most important effect for degradation rates is to avoid instrumentation that changes over time in the field. For instance, a drifting irradiance sensor, which can be achieved through regular calibration, can lead to a substantially erroneous degradation rates. However, the accuracy of the irradiance sensor has negligible impact on degradation rate uncertainty emphasizing that precision (relative accuracy) is more important than absolute accuracy.

Jordan, D.; Kurtz, S.; Hansen, C.

2014-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "kv rating mva" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Rating of Solar Energy Devices (Texas)  

Broader source: Energy.gov [DOE]

The Public Utility Commission has regulatory authority over solar energy devices installed and used in the state of Texas. The Commission can choose to adopt standards pertaining to the rating of...

322

Extended range radiation dose-rate monitor  

DOE Patents [OSTI]

An extended range dose-rate monitor is provided which utilizes the pulse pileup phenomenon that occurs in conventional counting systems to alter the dynamic response of the system to extend the dose-rate counting range. The current pulses from a solid-state detector generated by radiation events are amplified and shaped prior to applying the pulses to the input of a comparator. The comparator generates one logic pulse for each input pulse which exceeds the comparator reference threshold. These pulses are integrated and applied to a meter calibrated to indicate the measured dose-rate in response to the integrator output. A portion of the output signal from the integrator is fed back to vary the comparator reference threshold in proportion to the output count rate to extend the sensitive dynamic detection range by delaying the asymptotic approach of the integrator output toward full scale as measured by the meter.

Valentine, Kenneth H. (Knoxville, TN)

1988-01-01T23:59:59.000Z

323

Data Fusion for Improved Respiration Rate Estimation  

E-Print Network [OSTI]

We present an application of a modified Kalman-Filter (KF) framework for data fusion to the estimation of respiratory rate from multiple physiological sources which is robust to background noise. A novel index of the ...

Nemati, Shamim

324

Negotiating Rates and Contracts for Qualifying Facilities  

E-Print Network [OSTI]

The implementation of a cogeneration project or other qualifying facility (QF) requires the development of contractual relationships with one or more electric utilities. The relationships may involve the application of existing rates and contracts...

Collier, S. E.

325

Rating the energy performance of buildings  

SciTech Connect (OSTI)

In order to succeed in developing a more sustainable society, buildings will need to be continuously improved. This paper discusses how to rate the energy performance of buildings. A brief review of recent approaches to energy rating is presented. It illustrates that there is no single correct or wrong concept, but one needs to be aware of the relative impact of the strategies. Different strategies of setting energy efficiency standards are discussed and the advantages of the minimum life cycle cost are shown. Indicators for building energy rating based on simulations, aggregated statistics and expert knowledge are discussed and illustrated in order to demonstrate strengths and weaknesses of each approach. In addition, the importance of considering the level of amenities offered is presented. Attributes of a rating procedure based on three elements, flexible enough for recognizing different strategies to achieve energy conservation, is proposed.

Olofsson, Thomas; Meier, Alan; Lamberts, Roberto

2004-12-01T23:59:59.000Z

326

Mervento 3.6-118 Recycling Rate.  

E-Print Network [OSTI]

??My Bachelor’s thesis work has been to make an investigation of the recycling rate of Mervento Oy's new wind turbine Mervento 3.6-118. The study has… (more)

Forsman, Andreas

2012-01-01T23:59:59.000Z

327

An Air-Flow Rate Regulator  

Science Journals Connector (OSTI)

A circuit that automatically maintains a constant airflow rate (1.2 l/min) is described. The device is used in an A3-5 aerosol-particle counter.

V. K. Kovalevskii; E. V. Pokrovskii

2001-03-01T23:59:59.000Z

328

BPA proposes rate increase to bolster  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

RELEASE Thursday, Nov. 8, 2012 CONTACT: Mike Hansen, 503-230-4328 or 503-230-5131 BPA proposes rate increase to bolster federal power and transmission systems Portland, Ore....

329

Utility Rate | OpenEI Community  

Open Energy Info (EERE)

Replies Last Post sort icon Blog entry Database Announcing New Utility Rate Database and API Features Ewilson 1 21 Jul 2014 - 15:48 Groups Menu You must login in order to post...

330

Dynamic Line Rating: Research and Policy Evaluation  

SciTech Connect (OSTI)

Dynamic Line Rating (DLR) is a smart grid technology that allows the rating of electrical conductors to be increased based on local weather conditions. Overhead lines are conventionally given a conservative rating based on worst case scenarios. We demonstrate that observing the conditions in real time leads to additional capacity and safer operation. This paper provides a report of a pioneering scheme in the United States of America in which DLR has been applied. Thereby, we demonstrate that observing the local weather conditions in real time leads to additional capacity and safer operation. Secondly, we discuss limitations involved. In doing so, we arrive at novel insights which will inform and improve future DLR projects. Third, we provide a policy background and discussion to clarify the technology’s potential and identifies barriers to the imminent adoption of dynamic line rating systems. We provide suggestions for regulatory bodies about possible improvements in policy to encourage adoption of this beneficial technology.

Jake P. Gentle; Kurt S. Myers; Michael R. West

2014-07-01T23:59:59.000Z

331

Should thermodynamics be X-rated?  

Science Journals Connector (OSTI)

Should thermodynamics be X-rated? ... A simple analogy is suggested illustrating the thermodynamic sign convention and the significance of the negative sign of ?H and ?G on spontaneity for general or introductory chemistry students. ...

Henry A. Bent

1985-01-01T23:59:59.000Z

332

Extratropical Lapse Rates in Very Hot Climates  

E-Print Network [OSTI]

are neutral with respect to moist convection, and large where lapse rates are stable. Using P* allows us to examine convective motions arising from both gravitational accelerations as well as symmetric instabilities. We assess the ability of current models...

Zamora, Ryan Alexander

2013-07-02T23:59:59.000Z

333

EMU and Transatlantic Exchange Rate Stability  

Science Journals Connector (OSTI)

The macroeconomic debate about EMU has always focused on the costs and the benefits of suppressing exchange rates between the participating countries. These costs and benefits actually depend on whether the excha...

Agnès Bénassy-Quéré; Benoît Mojon

2001-01-01T23:59:59.000Z

334

Utility Rate | OpenEI Community  

Open Energy Info (EERE)

Utility Rate Home > Utility Rate > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: energy efficiency Type Term Title Author Replies Last Post sort icon Blog entry energy efficiency FOA aimed at growing expansive database of Renewable Energy and Energy Efficiency Incentives and Policies Graham7781 12 Dec 2012 - 11:30 Groups Menu You must login in order to post into this group. Recent content FYI, OpenEI now accommodates t... Very useful information. Thank... The utility rate database version 1 API is now deprecated Glad I could help get you on t... Nick, Thanks very much! That... more Group members (25) Managers: Dloomis Rmckeel Sfomail Recent members: Denizurla Bazouing Gdavis Shehant Anapettirossi Abkatzman BijouLulla Vbugnion

335

Utility Rate Discount | Open Energy Information  

Open Energy Info (EERE)

Discount Discount Jump to: navigation, search A few electric utilities offer rate discounts to encourage residential energy efficiency. For homes that meet certain energy efficiency criteria, such as those established by the federal Energy Star program, the owner or tenant is awarded a percentage discount on each monthÂ’s electric bill. [1] Utility Rate Discount Incentives CSV (rows 1 - 14) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active Cleco Power - Power Miser New Home Program (Louisiana) Utility Rate Discount Louisiana Residential Building Insulation Central Air conditioners Clothes Washers Comprehensive Measures/Whole Building Doors Duct/Air sealing Furnaces Heat pumps Water Heaters Windows Yes Dominion North Carolina Power - Energy Saver Home Plus (North Carolina) Utility Rate Discount North Carolina Residential Water Heaters

336

Commercial Building Energy Asset Rating Workshop  

Broader source: Energy.gov (indexed) [DOE]

BUILDING BUILDING ENERGY ASSET RATING WORKSHOP December 8-9, 2011 Washington, D.C. Nora Wang (Pacific Northwest National Laboratory) Will Gorrissen (Pacific Northwest National Laboratory) Molly McCabe (Hayden Tanner, LLC) Cody Taylor (Department of Energy) 1 I Asset Rating D.C. Workshop eere.energy.gov PRE-DECISIONAL Information included in this document is for discussion purposes and does not constitute the final program design. FOR INFORMATION ONLY 2 I Asset Rating D.C. Workshop eere.energy.gov Program Goals * Facilitate cost-effective investment in energy efficiency and reduce energy use in the commercial building sector * Establish a national standard for voluntary commercial building asset rating * Create a tool to help building owners identify and implement

337

Calibration and Rating of Photovoltaics: Preprint  

SciTech Connect (OSTI)

Rating the performance of photovoltaic (PV) modules is critical to determining the cost per watt, and efficiency is useful to assess the relative progress among PV concepts. Procedures for determining the efficiency for PV technologies from 1-sun to low concentration to high concentration are discussed. We also discuss the state of the art in primary and secondary calibration of PV reference cells used by calibration laboratories around the world. Finally, we consider challenges to rating PV technologies and areas for improvement.

Emery, K.

2012-06-01T23:59:59.000Z

338

Solar Models and NACRE thermonuclear reaction rates  

E-Print Network [OSTI]

Using the most recent updated physics, calibrated solar models have been computed with the new thermonuclear reaction rates of NACRE, the recently available European compilation. Comparisons with models computed with the reaction rates of Caughlan & Fowler (\\cite{cf88}) and of Adelberger et al. (\\cite{a98}) are made for global structure, expected neutrinos fluxes, chemical composition and sound speed profiles, helioseismological properties of p-modes and g-modes.

P. Morel; B. Pichon; J. Provost; G. Berthomieu

1999-07-27T23:59:59.000Z

339

Rate allocation in a remote control structure  

E-Print Network [OSTI]

measuzes. The quantized control problem, in general, has vector sources with weighted distortion measures. The rate allocation scheme of Goodman, must therefore be modified to allow for vector sources. Chapter 3 will specifically address the problem... of rate allocation given vector sources and weighted distortion measures' Equations will be derived for the case when the measurements and controls are assumed independent and when they are dependent. k + k P k (a) k/k-1 (b) Fig. 2. DPCM (a...

Meadow, Charles Joe

1984-01-01T23:59:59.000Z

340

Pump-1-A Wholesale Power Rate Schedule | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

1-A Wholesale Power Rate Schedule Pump-1-A Wholesale Power Rate Schedule Area: Carters & Russell Pumping System: Georgia-Alabama-South Carolina This rate schedule shall be...

Note: This page contains sample records for the topic "kv rating mva" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Analysis of Water Rate Escalations Across the United States ...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Analysis of Water Rate Escalations Across the United States Analysis of Water Rate Escalations Across the United States Report describes an analysis of water rate escalations...

342

Trip rate comparison of workplace and household surveys  

E-Print Network [OSTI]

Available vs. Trip Rate) 14 El Paso Household Survey (Household Income vs. Trip Rate) . 15 El Paso Workplace Survey (Household Income vs. Trip Rate) . 52 52 53 53 54 54 16 BPA Household Survey (Household Size vs. Trip Rate) . . 17 BPA Workplace... Survey (Household Size vs. Trip Rate) . . 56 56 18 BPA Household Survey (No. of Employees vs. Trip Rate) . . 19 BPA Workplace Survey (No. of Employees vs. Trip Rate) . . 20 BPA Household Survey (Vehicles Available vs. Trip Rate) . . 21 BPA Workplace...

Endres, Stephen Michael

2012-06-07T23:59:59.000Z

343

Property:HeatRate | Open Energy Information  

Open Energy Info (EERE)

HeatRate HeatRate Jump to: navigation, search This is a property of type Number. Pages using the property "HeatRate" Showing 25 pages using this property. (previous 25) (next 25) A AES Mendota Biomass Facility + 17,873.6 + APS Biomass I Biomass Facility + 8,911 + Acme Landfill Biomass Facility + 12,916.67 + Adrian Energy Associates LLC Biomass Facility + 13,170.6 + Agrilectric Power Partners Ltd Biomass Facility + 17,327.1 + Al Turi Biomass Facility + 15,600.2 + Alabama Pine Pulp Biomass Facility + 15,826.23 + Albany Landfill Gas Utilization Project Biomass Facility + 11,913.9 + Altamont Gas Recovery Biomass Facility + 10,500 + American Canyon Power Plant Biomass Facility + 10,886.8 + American Ref-Fuel of Delaware Valley Biomass Facility + 18,674.9 +

344

Utility Rate | OpenEI Community  

Open Energy Info (EERE)

Utility Rate Utility Rate Home > Groups Content Group Activity By term Q & A Feeds Share your own status updates, and follow the updates & activities of others by creating your own account. Or, remember to log in If you already have an account. Groups Menu You must login in order to post into this group. Recent content There is currently no way to s... ranking of utilities by demand charge? FYI, OpenEI now accommodates t... Very useful information. Thank... The utility rate database version 1 API is now deprecated more Group members (28) Managers: Dloomis Rmckeel Sfomail Recent members: MSiira Apin101 Lissacoffey Denizurla Bazouing Gdavis Shehant Anapettirossi Abkatzman BijouLulla Vbugnion Marklane Cbonsig Verdel3c Wisconsin Weatherall Windows Payne Nlong Wzeng 429 Throttled (bot load)

345

Analytical Improvements in PV Degradation Rate Determination  

SciTech Connect (OSTI)

As photovoltaic (PV) penetration of the power grid increases, it becomes vital to know how decreased power output may affect cost over time. In order to predict power delivery, the decline or degradation rates must be determined accurately. For non-spectrally corrected data several complete seasonal cycles (typically 3-5 years) are required to obtain reasonably accurate degradation rates. In a rapidly evolving industry such a time span is often unacceptable and the need exists to determine degradation rates accurately in a shorter period of time. Occurrence of outliers and data shifts are two examples of analytical problems leading to greater uncertainty and therefore to longer observation times. In this paper we compare three methodologies of data analysis for robustness in the presence of outliers, data shifts and shorter measurement time periods.

Jordan, D. C.; Kurtz, S. R.

2011-02-01T23:59:59.000Z

346

Critical reaction rates in hypersonic combustion chemistry  

SciTech Connect (OSTI)

High Mach number flight requires that the scramjet propulsion system operate at a relatively low static inlet pressure and a high inlet temperature. These two constraints can lead to extremely high temperatures in the combustor, yielding high densities of radical species and correspondingly poor chemical combustion efficiency. As the temperature drops in the nozzle expansion, recombination of these excess radicals can produce more product species, higher heat yield, and potentially more thrust. The extent to which the chemical efficiency can be enhanced in the nozzle expansion depends directly on the rate of the radical recombination reactions. A comprehensive assessment of the important chemical processes and an experimental validation of the critical rate parameters is therefore required if accurate predictions of scramjet performance are to be obtained. This report covers the identification of critical reactions, and the critical reaction rates in hypersonic combustion chemistry. 4 refs., 2 figs.

Oldenborg, R.C.; Harradine, D.M.; Loge, G.W.; Lyman, J.L.; Schott, G.L.; Winn, K.R.

1989-01-01T23:59:59.000Z

347

Intramolecular ET Rates in Modified Ferrocytochromes c  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Intramolecular Electron-Transfer Rates on Driving Force, pH, Intramolecular Electron-Transfer Rates on Driving Force, pH, and Temperature in Ammineruthenium-Modified Ferrocytochromes c James F. Wishart, Ji Sun, Myung Cho, Chang Su, and Stephan S. Isied J. Phys. Chem. B 101, 687-693 (1997) [Find paper at ACS Publications] or use ACS Articles on Request Abstract: Several ruthenium ammine complexes were used to modify horse-heart cytochrome c at histidine-33, creating a series of (NH3)4(L)Ru-Cyt c derivatives (L = H2O/OH-, ammonia, 4-ethylpyridine, 3,5-lutidine, pyridine, isonicotinamide, N-methylpyrazinium) with a wide range of driving forces for Fe-to-Ru electron transfer (-DG° = -0.125 to +0.46 eV). Electron-transfer rates and activation parameters were measured by pulse radiolysis using azide or carbonate radicals. The driving-force dependence

348

Neutrino Event Rates from Gamma Ray Bursts  

E-Print Network [OSTI]

We recalculate the diffuse flux of high energy neutrinos produced by Gamma Ray Bursts (GRB) in the relativistic fireball model. Although we confirm that the average single burst produces only ~10^{-2} high energy neutrino events in a detector with 1 km^2 effective area, i.e. about 10 events per year, we show that the observed rate is dominated by burst-to-burst fluctuations which are very large. We find event rates that are expected to be larger by one order of magnitude, likely more, which are dominated by a few very bright bursts. This greatly simplifies their detection.

F. Halzen; D. W. Hooper

1999-08-12T23:59:59.000Z

349

Using Same-Hospital Readmission Rates to Estimate All-Hospital Readmission Rates  

Science Journals Connector (OSTI)

Background Since October of 2012, Medicare's Hospital Readmissions Reduction Program has fined 2,200 hospitals a total of $500 million. Although the program penalizes readmission to any hospital, many institutions can only track readmissions to their own hospitals. We sought to determine the extent to which same-hospital readmission rates can be used to estimate all-hospital readmission rates after major surgery. Study Design We evaluated 3,940 hospitals treating 741,656 Medicare fee-for-service beneficiaries undergoing CABG, hip fracture repair, or colectomy between 2006 and 2008. We used hierarchical logistic regression to calculate risk- and reliability-adjusted rates of 30-day readmission to the same hospital and to any hospital. We next evaluated the correlation between same-hospital and all-hospital rates. To analyze the impact on hospital profiling, we compared rankings based on same-hospital rates with those based on all-hospital rates. Results The mean risk- and reliability-adjusted all-hospital readmission rate was 13.2% (SD 1.5%) and mean same-hospital readmission rate was 8.4% (SD 1.1%). Depending on the operation, between 57% (colectomy) and 63% (CABG) of hospitals were reclassified when profiling was based on same-hospital readmission rates instead of on all-hospital readmission rates. This was particularly pronounced in the middle 3 quintiles, where 66% to 73% of hospitals were reclassified. Conclusions In evaluating hospital profiling under Medicare's Hospital Readmissions Reduction Program, same-hospital rates provide unstable estimates of all-hospital readmission rates. To better anticipate penalties, hospitals require novel approaches for accurately tracking the totality of their postoperative readmissions.

Andrew A. Gonzalez; Terry Shih; Justin B. Dimick; Amir A. Ghaferi

2014-01-01T23:59:59.000Z

350

VI. References V. Realistic Learning (Rate Based  

E-Print Network [OSTI]

VI. References V. Realistic Learning (Rate Based III. Mean Field Model IV. Spike Timing Depended Results Batch Learning ber of pattern stored patterns Low pass filtering: Presynaptic Adaptation ( ):see Christian Albers and Klaus Pawelzik University of Bremen -- Institute for Theoretical Physics -- Department

Kreiter, Andreas K.

351

Single Assessment Pass Rate South Carolina  

E-Print Network [OSTI]

Single Assessment Pass Rate South Carolina Academic Year 2000 - 2001 ETS Type of Assessment Test Code Total Pass % Pass Total Pass % Pass Academic Content Area Education in the Elementary School 0010., & Comp.: Essays 0042 Mathematics 0060 1 1 100% 47 45 96% Chemistry, Physics and General Science 0070 5 3

Kasman, Alex

352

Sound insulation ratings—the STC revisited  

Science Journals Connector (OSTI)

About twenty years ago building authorities and their acoustical experts were faced with a confusing variety of schemes for rating the sound insulation of walls and floors. There was need for a definitive rating system that would digest the 16 transmission loss values that characterize a partition and produce a single number that would describe its sound insulation performance especially in respect to multi?family dwellings. Two standards committees ISO/TC 43 and ASTM E6 (now E33) began more or less together to develop a new improved rating system to fill this need. The product of these labors was what is known in North America as the ASTM sound transmission class (STC). This rating system was so successful that it was almost universally adopted—even in applications for which it was not intended. Despite the apparent success there is now increasing awareness of imperfections in the system. These are examined in light of accumulated data and experience to see whether the system could or should be improved by certain minor changes.

T. D. Northwood

1981-01-01T23:59:59.000Z

353

COMMODITY PRICE VOLATILITY ACROSS EXCHANGE RATE REGIMES  

E-Print Network [OSTI]

1 COMMODITY PRICE VOLATILITY ACROSS EXCHANGE RATE REGIMES John T. Cuddington* and Hong Liang** March 10, 2003 ABSTRACT This paper documents a new "stylized fact" regarding the relative price 1880 to 1996, this key relative price among two categories of tradable goods is shown to exhibit

354

The distant type Ia supernova rate  

SciTech Connect (OSTI)

We present a measurement of the rate of distant Type Ia supernovae derived using 4 large subsets of data from the Supernova Cosmology Project. Within this fiducial sample,which surveyed about 12 square degrees, thirty-eight supernovae were detected at redshifts 0.25--0.85. In a spatially flat cosmological model consistent with the results obtained by the Supernova Cosmology Project, we derive a rest-frame Type Ia supernova rate at a mean red shift z {approx_equal} 0.55 of 1.53 {sub -0.25}{sub -0.31}{sup 0.28}{sup 0.32} x 10{sup -4} h{sup 3} Mpc{sup -3} yr{sup -1} or 0.58{sub -0.09}{sub -0.09}{sup +0.10}{sup +0.10} h{sup 2} SNu(1 SNu = 1 supernova per century per 10{sup 10} L{sub B}sun), where the first uncertainty is statistical and the second includes systematic effects. The dependence of the rate on the assumed cosmological parameters is studied and the redshift dependence of the rate per unit comoving volume is contrasted with local estimates in the context of possible cosmic star formation histories and progenitor models.

Pain, R.; Fabbro, S.; Sullivan, M.; Ellis, R.S.; Aldering, G.; Astier, P.; Deustua, S.E.; Fruchter, A.S.; Goldhaber, G.; Goobar, A.; Groom, D.E.; Hardin, D.; Hook, I.M.; Howell, D.A.; Irwin, M.J.; Kim, A.G.; Kim, M.Y.; Knop, R.A.; Lee, J.C.; Perlmutter, S.; Ruiz-Lapuente, P.; Schahmaneche, K.; Schaefer, B.; Walton, N.A.

2002-05-20T23:59:59.000Z

355

A New Rate Law Describing Microbial Respiration  

Science Journals Connector (OSTI)

...Academic Press, Inc., New York, N.Y. 8 Conrad, R...Regulation of cellular energy metabolism. J. Membr...Oxford University Press, New York, N.Y. A new rate law describing microbial...term accounting for the energy available in the microbe's...

Qusheng Jin; Craig M. Bethke

2003-04-01T23:59:59.000Z

356

Heart Rate Variability Malvin Carl Teich  

E-Print Network [OSTI]

Heart Rate Variability Malvin Carl Teich Boston University and Columbia University http, Grasmere, UK, 2005 #12;CONGESTIVE HEART FAILURE INABILITY OF HEART TO INCREASE CARDIAC OUTPUT IN PROPORTION of breath Swelling in legs General fatigue and weakness Clinical diagnostics: Ascultate heart Carotid pulse

Teich, Malvin C.

357

Tier 2 Vintage Rate Workshop II  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

I N I S T R A T I O N Proposed Access to Market-based Vintage Rate in FY 2014 Guaranteed: Load Following customer with <1 aMW of forecast Short-Term service in FY 2014: NA Load...

358

Heart Physiology Lab Part 1: Pulse Rate  

E-Print Network [OSTI]

Heart Physiology Lab Part 1: Pulse Rate Measure your pulse in each of the following conditions (in in the class. You may use Table 1 in the Heart Physiology Worksheet for this, if you wish. Once you have all of the class averages for each measurement. You may use Graph 1 in the Heart Physiology Worksheet for this

Loughry, Jim

359

SUPPLY-SIDE OPTIMIZATION : MAXIMIZING ABSORPTIVE RATES  

E-Print Network [OSTI]

-benefit optimization of the ingestion process alone . We have continued to develop and modify chemical reactor theoryI l SUPPLY-SIDE OPTIMIZATION : MAXIMIZING ABSORPTIVE RATES W. Brian Dade, Peter A. Jumars engineering aimed at the analysis and design of chemical reactors to analyze the process of digestion

Jumars, Pete

360

Optimizing bit hydraulics increases penetration rate  

SciTech Connect (OSTI)

At some point, rate of penetration depends as much or more on hydraulics as on bit weight and rotary speed. An easy-to-follow graphical technique shows how to maximize ROP at the rig by finding the optimum pressure drop through the bit and the highest possible crossflow velocity.

Robinson, L.

1982-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "kv rating mva" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

High temperature electrochemical corrosion rate probes  

SciTech Connect (OSTI)

Corrosion occurs in the high temperature sections of energy production plants due to a number of factors: ash deposition, coal composition, thermal gradients, and low NOx conditions, among others. Electrochemical corrosion rate (ECR) probes have been shown to operate in high temperature gaseous environments that are similar to those found in fossil fuel combustors. ECR probes are rarely used in energy production plants at the present time, but if they were more fully understood, corrosion could become a process variable at the control of plant operators. Research is being conducted to understand the nature of these probes. Factors being considered are values selected for the Stern-Geary constant, the effect of internal corrosion, and the presence of conductive corrosion scales and ash deposits. The nature of ECR probes will be explored in a number of different atmospheres and with different electrolytes (ash and corrosion product). Corrosion rates measured using an electrochemical multi-technique capabilities instrument will be compared to those measured using the linear polarization resistance (LPR) technique. In future experiments, electrochemical corrosion rates will be compared to penetration corrosion rates determined using optical profilometry measurements.

Bullard, Sophie J.; Covino, Bernard S., Jr.; Holcomb, Gordon R.; Ziomek-Moroz, M.

2005-09-01T23:59:59.000Z

362

The Distant Type Ia Supernova Rate  

DOE R&D Accomplishments [OSTI]

We present a measurement of the rate of distant Type Ia supernovae derived using 4 large subsets of data from the Supernova Cosmology Project. Within this fiducial sample, which surveyed about 12 square degrees, thirty-eight supernovae were detected at redshifts 0.25--0.85. In a spatially flat cosmological model consistent with the results obtained by the Supernova Cosmology Project, we derive a rest-frame Type Ia supernova rate at a mean red shift z {approx_equal} 0.55 of 1.53 {sub -0.25}{sub -0.31}{sup 0.28}{sup 0.32} x 10{sup -4} h{sup 3} Mpc{sup -3} yr{sup -1} or 0.58{sub -0.09}{sub -0.09}{sup +0.10}{sup +0.10} h{sup 2} SNu(1 SNu = 1 supernova per century per 10{sup 10} L{sub B}sun), where the first uncertainty is statistical and the second includes systematic effects. The dependence of the rate on the assumed cosmological parameters is studied and the redshift dependence of the rate per unit comoving volume is contrasted with local estimates in the context of possible cosmic star formation histories and progenitor models.

Pain, R.; Fabbro, S.; Sullivan, M.; Ellis, R. S.; Aldering, G.; Astier, P.; Deustua, S. E.; Fruchter, A. S.; Goldhaber, G.; Goobar, A.; Groom, D. E.; Hardin, D.; Hook, I. M.; Howell, D. A.; Irwin, M. J.; Kim, A. G.; Kim, M. Y.; Knop, R. A.; Lee, J. C.; Perlmutter, S.; Ruiz-Lapuente, P.; Schahmaneche, K.; Schaefer, B.; Walton, N. A.

2002-05-28T23:59:59.000Z

363

Prediction of Thermonuclear Reaction Rates in Astrophysics  

E-Print Network [OSTI]

Recent improvements and remaining problems in the prediction of thermonuclear rates are reviewed. The main emphasis is on statistical model calculations, but the challenge to include direct reactions close to the driplines is also briefly addressed. Further theoretical as well as experimental investigations are motivated.

T. Rauscher

1998-10-15T23:59:59.000Z

364

Improving energy efficiency via probabilistic rate combination in 802.11 multi-rate wireless networks  

E-Print Network [OSTI]

transmission. An alternative way to conserve energy is to apply power control [1­4]. A wireless node is allowedImproving energy efficiency via probabilistic rate combination in 802.11 multi-rate wireless in revised form 20 January 2009 Accepted 27 January 2009 Available online 6 February 2009 Keywords: Energy

Lui, John C.S.

365

Nominal exchange rate pegging, escape clauses and targeting of the real exchange rate  

E-Print Network [OSTI]

We consider an economy under a fixed exchange rate system, but with bounds (a minimum level or a band) on the real exchange rate. The international price of the tradable good is characterized by the continuous arrival of shocks that change its level...

Gonzalez, Pablo

2006-08-16T23:59:59.000Z

366

Construction Project Number  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

North Execution - (2009 - 2011) North Execution - (2009 - 2011) Construction Project Number 2009 2010 2011 Project Description ANMLPL 0001C 76,675.32 - - Animas-Laplata circuit breaker and power rights CRGRFL 0001C - - 7,177.09 Craig Rifle Bay and transfer bay upgrade to 2000 amps; / Convert CRG RFL to 345 kV out of Bears Ear Sub FGE 0019C - - 39,207.86 Replace 69/25kV transformer KX2A at Flaming Gorge FGE 0020C - - 52,097.12 Flaming Gorge: Replace failed KW2A transformer HDN 0069C 16,638.52 208,893.46 3,704,578.33 Replace failed transformer with KZ1A 250 MVA 230/138kv

367

Rate Us - ORNL DAAC Feedback Forum  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Help > Feedback Help > Feedback Rate Us - ORNL DAAC Feedback Forum To improve service to our customers, this forum provides a means to monitor user satisfaction. Please take a moment to tell us about your experience. Consider Data availability, accessibility, and value Web navigation and content Customer service Your responses will remain anonymous in keeping with our Privacy Policy. Select one of the following options that best describes your experience with the ORNL DAAC. Positive Mixed Negative If you wish to add comments or to explain your rating, please enter your comments in the box below. If you would like us to reply to your comments or concern, please enter your e-mail address here: Please solve the following simple math problem: 4 x 2 = help icon Submit Feedback Clear form

368

Muon capture rates within the projected QRPA  

E-Print Network [OSTI]

The conservation of the number of particles within the QRPA plays an important role in the evaluation muon capture rates in all light nuclei with A \\precsim 30 . The violation of the CVC by the Coulomb field in this mass region is of minor importance, but this effect could be quite relevant for medium and heavy nuclei studied previously. The extreme sensitivity of the muon capture rates on the 'pp' coupling strength in nuclei with large neutron excess when described within the QRPA is pointed out. We reckon that the comparison between theory and data for the inclusive muon capture is not a fully satisfactory test on the nuclear model that is used. The exclusive muon transitions are much more robust for such a purpose.

Danilo Sande Santos; Arturo R. Samana; Francisco Krmpoti?; Alejandro J. Dimarco

2012-03-03T23:59:59.000Z

369

Strain rate effects in porous materials  

SciTech Connect (OSTI)

The behavior of metal foams under rapid loading conditions is assessed. Dynamic loading experiments were conducted in their laboratory using a split Hopkinson pressure bar apparatus and a drop weight tester; Strain rates ranged from 45 s{sup {minus}1} to 1200 s{sup {minus}1}. The implications of these experiments on open-cell, porous metals, and closed- and open-cell polymer foams are described. It is shown that there are two possible strain-rate dependent contributors to the impact resistance of cellular metals: (i) elastic-plastic resistance of the cellular metal skeleton, and (ii) the gas pressure generated by gas flow within distorted open cells. A theoretical basis for these implications is presented.

Lankford, J. Jr.; Dannemann, K.A. [Southwest Research Inst., San Antonio, TX (United States)

1998-12-31T23:59:59.000Z

370

UK now claims world's top discovery rate  

SciTech Connect (OSTI)

UK explorers are a bit more cheerful these days even though no one has discovered a giant field or anything elephant-sized. The reason is a benign tax regime and a growing confidence among industry explorers. This last has resulted in discovery of many smaller fields - particularly gas, some potentially commercial. It is claimed that the UK's discovery rate is now the highest in the world.

Not Available

1985-05-01T23:59:59.000Z

371

Energy loss rate in disordered quantum well  

SciTech Connect (OSTI)

We report the effect of dynamically screened deformation potential on the electron energy loss rate in disordered semiconductor quantum well. Interaction of confined electrons with bulk acoustic phonons has been considered in the deformation coupling. The study concludes that the dynamically screened deformation potential coupling plays a significant role as it substantially affects the power dependency of electron relaxation on temperature and mean free path.

Tripathi, P.; Ashraf, S. S. Z. [Centre of Excellence in Nanomaterials, Faculty of Engineering and Technology, Aligarh Muslim University, Aligarh-202002 (India); Hasan, S. T. [Physics Department, Faculty of Science, The M.S. University of Baroda, Vadodara-390002 (India); Sharma, A. C. [Physics Department, Sibli National College, Azamgarh-276128 (India)

2014-04-24T23:59:59.000Z

372

Category:Utility Rates | Open Energy Information  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Category Edit History Facebook icon Twitter icon » Category:Utility Rates Jump to: navigation, search Add a new Utility Rate Pages in category "Utility Rates" The following 200 pages are in this category, out of 42,539 total. (previous 200) (next 200) 0 Data:0000827d-84d0-453d-b659-b86869323897 Data:000086db-7a5e-4356-9c57-c912f7d1622e Data:0003a8b3-04b9-4ecb-b06d-6022e7f0f009 Data:000470c7-df04-47aa-bdd2-d70f0a2c52b3 Data:000b6dfa-a541-428a-9029-423006e22a34 Data:000db36e-b548-43e7-a283-d37ecc77cef1 Data:000e60f7-120d-48ab-a1f9-9c195329c628 Data:00101108-073b-4503-9cd4-01769611c26f Data:001361ca-50d2-49bc-b331-08755a2c7c7d

373

Heating Rate Profiles in Galaxy Clusters  

E-Print Network [OSTI]

In recent years evidence has accumulated suggesting that the gas in galaxy clusters is heated by non-gravitational processes. Here we calculate the heating rates required to maintain a physically motived mass flow rate, in a sample of seven galaxy clusters. We employ the spectroscopic mass deposition rates as an observational input along with temperature and density data for each cluster. On energetic grounds we find that thermal conduction could provide the necessary heating for A2199, Perseus, A1795 and A478. However, the suppression factor, of the clasical Spitzer value, is a different function of radius for each cluster. Based on the observations of plasma bubbles we also calculate the duty cycles for each AGN, in the absence of thermal conduction, which can provide the required energy input. With the exception of Hydra-A it appears that each of the other AGNs in our sample require duty cycles of roughly $10^{6}-10^{7}$ yrs to provide their steady-state heating requirements. If these duty cycles are unrealistic, this may imply that many galaxy clusters must be heated by very powerful Hydra-A type events interspersed between more frequent smaller-scale outbursts. The suppression factors for the thermal conductivity required for combined heating by AGN and thermal conduction are generally acceptable. However, these suppression factors still require `fine-tuning` of the thermal conductivity as a function of radius. As a consequence of this work we present the AGN duty cycle as a cooling flow diagnostic.

Edward C. D. Pope; Georgi Pavlovski; Christian R. Kaiser; Hans Fangohr

2006-01-05T23:59:59.000Z

374

2007 Wholesale Power Rate Case Initial Proposal : Wholesale Power Rate Development Study.  

SciTech Connect (OSTI)

The Wholesale Power Rate Development Study (WPRDS) calculates BPA proposed rates based on information either developed in the WPRDS or supplied by the other studies that comprise the BPA rate proposal. All of these studies, and accompanying documentation, provide the details of computations and assumptions. In general, information about loads and resources is provided by the Load Resource Study (LRS), WP-07-E-BPA-01, and the LRS Documentation, WP-07-E-BPA-01A. Revenue requirements information, as well as the Planned Net Revenues for Risk (PNNR), is provided in the Revenue Requirement Study, WP-07-E-BPA-02, and its accompanying Revenue Requirement Study Documentation, WP-07-E-BPA-02A and WP-07-E-BPA-02B. The Market Price Forecast Study (MPFS), WP-07-E-BPA-03, and the MPFS Documentation, WP-07-E-BPA-03A, provide the WPRDS with information regarding seasonal and diurnal differentiation of energy rates, as well information regarding monthly market prices for Demand Rates. In addition, this study provides information for the pricing of unbundled power products. The Risk Analysis Study, WP-07-E-BPA-04, and the Risk Analysis Study Documentation, WP-07-E-BPA-04A, provide short-term balancing purchases as well as secondary energy sales and revenue. The Section 7(b)(2) Rate Test Study, WP-07-E-BPA-06, and the Section 7(b)(2) Rate Test Study Documentation, WP-07-E-BPA-06A, implement Section 7(b)(2) of the Northwest Power Act to ensure that BPA preference customers firm power rates applied to their general requirements are no higher than rates calculated using specific assumptions in the Northwest Power Act.

United States. Bonneville Power Administration.

2007-11-01T23:59:59.000Z

375

Cost of Service and Rate Design Issues Affecting Industrial Customers in Retail Rate Proceedings  

E-Print Network [OSTI]

COST OF SERVICE AND RATE DESIGN ISSUES AFFECTING INDUSTRIAL CUSTOHERS IN RETAIL RATE PROCEEDINGS CARL N. STOVER, JR. C. H. Guernsey &Company Oklahoma City, Oklahoma ABSTRACT There are generally three major areas of conCertl in a retail rate.... If energy costs are a significant element in the cost of doi~g business, then the industrial customer must be familiar with the activities involved in the ratemaking process, be aware of the issues that might be raised as a part of the process, know...

Stover, C. N. Jr.

376

Microsoft PowerPoint - anderson_epri.ppt  

Broader source: Energy.gov (indexed) [DOE]

Review Review ETO STATCOM Demonstration Project Update September 30, 2008 Wayne Litzenberger-DesignTech Loren Anderson-BPA Participants * DOE Energy Storage Program * Sandia National Lab * NCSU * EPRI * TVA * BPA * Florida State University-Center for Advanced Power Systems * Tri-State * AES-SeaWest * Commercial Vendor ? CONDON WIND FARM Proposed Host Site Full Scale Demonstration Project * 10 MVA STATCOM with battery storage * Adjacent to Condon Wind Park * Mitsubishi Type 1 induction machines * Poor voltage regulation * Long line with many small customers Proposed 10 MVA ETO STATCOM for Condon Wind Farm 0.6886mH I=1400 A (RMS) with IEEE 519 standards ETO Voltage Source Converter (transformer leakage inductance) I=1400 A (RMS) with IEEE 519 standards 69kv bus Condon Windfarm Problems

377

Integrated System Transmission and Ancillary Services Rate Calculation  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Transmission Rate 10 4.00 MillsKWh (L5 * 1000) 730 hours per month 7 RATE FOR SCHEDULING, SYSTEM CONTROL AND DISPATCH SERVICE FOR 2015 A. Fixed Charge Rate 21.652% (1)...

378

Effect of Uncertainties in Nuclear Reaction Rate on Nucleosynthesis Paths  

Science Journals Connector (OSTI)

......of Theoretical Physics, Vol. 123, No...Nuclear Reaction Rate on Nucleosynthesis...Nuclear Astro- physics Compilation of Reaction Rates (NACRE),2...synthesis paths pass through 20Ne or...18O reaction rate is larger than......

Kazuyuki Yamamoto; Kiyoshi Kato; Takahiro Wada; Masahisa Ohta

2010-06-01T23:59:59.000Z

379

CTV-1-H Wholesale Power Rate Schedule | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

CTV-1-H Wholesale Power Rate Schedule CTV-1-H Wholesale Power Rate Schedule Area: Tennessee Valley Authority System: CU This rate schedule shall be available to the Tennessee...

380

CBR-1-H Wholesale Power Rate Schedule | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

CBR-1-H Wholesale Power Rate Schedule CBR-1-H Wholesale Power Rate Schedule Area: Big Rivers and Henderson, KY System: CU This rate schedule shall be available to Big Rivers...

Note: This page contains sample records for the topic "kv rating mva" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

What's the rate? Disentangling the Weitzman and the Gollier effect  

E-Print Network [OSTI]

and Management 36, 201–208. What’s the Rate? DisentanglingPapers Year 2012 Paper 1121 What's the Rate? Disentangling© 2012 by author(s). What’s the Rate? Disentangling the

Traeger, Christian P.

2012-01-01T23:59:59.000Z

382

electricity rates for military bases | OpenEI Community  

Open Energy Info (EERE)

electricity rates for military bases Home > Groups > Utility Rate Hi, I was hoping to find rates for military bases, but have been unable to find anything. Are they just charged as...

383

Abnormal heart rate turbulence predicts the initiation of ventricular arrhythmias  

E-Print Network [OSTI]

atrial pacing with onset heart rate = 99 beats/min. (C)Thonet G, Vesin J-M, et al. Heart rate dynamics at the on-M, Barthel P, et al. Heart-rate turbulence after ventricular

Iwasa, Atsushi; Hwa, Michael; Hassankhani, Alborz; Liu, Taylor; Narayan, Sanjiv M

2005-01-01T23:59:59.000Z

384

Reducing Your Leak Rate Without Repairing Leaks  

E-Print Network [OSTI]

out of a thirteen-minute cycle, which meant they sat idle 76.9 percent of the time. We decided to divide the pneumatic circuit on each machine into two circuits, install an automatic solenoid valve, and program the PLC to shut the air off.... In this case, we decided to install an automatic solenoid valve at each position, and program the PLC to shut the air off to the position when it wasn?t operating. This reduced the leak rate by approximately 1100 scfm from 1500 scfm to 400 scfm. ...

Beals, C.

2005-01-01T23:59:59.000Z

385

Binary Capture Rates for Massive Protostars  

E-Print Network [OSTI]

The high multiplicity of massive stars in dense, young clusters is established early in their evolution. The mechanism behind this remains unresolved. Recent results suggest that massive protostars may capture companions through disk interactions with much higher efficiency than their solar mass counterparts. However, this conclusion is based on analytic determinations of capture rates and estimates of the robustness of the resulting binaries. We present the results of coupled n-body and SPH simulations of star-disk encounters to further test the idea that disk-captured binaries contribute to the observed multiplicity of massive stars.

Nickolas Moeckel; John Bally

2007-04-09T23:59:59.000Z

386

Pell Grant and Stafford Loan Graduation Rates  

E-Print Network [OSTI]

Pell Grant and Stafford Loan Graduation Rates Entering Freshmen Classes Fall 2005, Fall 2006 Grant 2005 501 19.4% 37.3% 44.1% Stafford Loan 2005 695 28.5% 49.5% 56.7% All Other 2005 2,910 35.6% 59.2% 64.5% Total 2005 4,106 32.4% 54.9% 60.7% Pell Grant 2006 468 23.9% 44.4% 51.3% Stafford Loan 2006 663

387

Measurements of Relative K Radiative Decay Rates  

Science Journals Connector (OSTI)

Relative radiative decay rates were measured for K-shell vacancies for elements between Z=62 and 92 with a high-resolution Ge(Li) spectrometer. The ratios ?2?1, ?1??1, and ?2??1 (Siegbahn notation) were determined, with ?2?1 significantly higher (4-14%) than those reported by Beckman but in excellent agreement with recent Hartree-Slater calculations of Scofield. The ratios ?1??1 and ?2??1 do not agree with either Beckman's experiment or Scofield's calculations.

P. J. Ebert and V. W. Slivinsky

1969-12-05T23:59:59.000Z

388

High Metal Removal Rate Process for Machining Difficult Materials...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

High Metal Removal Rate Process for Machining Difficult Materials High Metal Removal Rate Process for Machining Difficult Materials highmetalremovalprocessfactsheet.pdf More...

389

Western-UGP Transmission and Ancillary Services Rates Customer...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

16, 2014, with changes noted in the following sections: Proposed Formula Rate for Scheduling, System Control and Dispatch Service, Proposed Rate for Regulation and...

390

Fair rate assignment in interference limited multi-hop networks  

E-Print Network [OSTI]

Optimal Link Scheduling and Power Control in CDMA MultihopB. Shro?. , “Joint rate control and scheduling in multihopthe joint rate control and scheduling problem, and [26

Arisoylu, Mustafa

2006-01-01T23:59:59.000Z

391

PowerChoice Residential Customer Response to TOU Rates  

E-Print Network [OSTI]

Load Data .and Swing rate season load- data analysis Tariff Periodperiods used for the Summer and Swing rate season load-data

Peters, Jane S.

2010-01-01T23:59:59.000Z

392

Widget:UtilityRateEntryHelperVideo | Open Energy Information  

Open Energy Info (EERE)

Jump to: navigation, search This widget displays the utility rate database form helper video. For example: Widget:UtilityRateEntryHelperVideo Retrieved from "http:...

393

CSI-1-H Wholesale Power Rate Schedule | Department of Energy  

Energy Savers [EERE]

Area: Southern Illinois System: CU This rate schedule shall be available to Southern Illinois Power Cooperative (hereinafter the Customer). This rate schedule shall be...

394

Fact #659: January 24, 2011 Fuel Economy Ratings for Vehicles...  

Energy Savers [EERE]

9: January 24, 2011 Fuel Economy Ratings for Vehicles Operating on Electricity Fact 659: January 24, 2011 Fuel Economy Ratings for Vehicles Operating on Electricity The...

395

Workshop on Thermonuclear Reaction Rates for Astrophysics Applications  

E-Print Network [OSTI]

Workshop on Thermonuclear Reaction Rates for Astrophysics Applications 24-25 November 2011, Athensrd and final circular for the Workshop on Thermonuclear Reaction Rates for Astrophysics Applications

396

Control Strategies for Centrifugal Pumps with Variable Flow Rate...  

Broader source: Energy.gov (indexed) [DOE]

Control Strategies for Centrifugal Pumps with Variable Flow Rate Requirements Control Strategies for Centrifugal Pumps with Variable Flow Rate Requirements This tip sheet discusses...

397

Provo River Project Power Sales Rate History  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Provo River Project Power Sales Rate History Updated: 12/20/2013 Rate Schedule Effective Dates Energy (Mills/kWh) Capacity ($/kW-mo.) Combined (Mills/kWh) Administrative Action 4/58 - 6/64 (Summer Season) 3.000 N.A. N.A. Administrative Action 10/58 - 4/64 (Winter Season) 4.500 N.A. N.A. Administrative Action 7/64 - 9/79 (Summer Season) 5.000 N.A. N.A. Administrative Action 10/64 - 9/79 (Winter Season) 3.000 N.A. N.A. Administrative Action 10/79 - 9/82 6.000 N.A. N.A. Administrative Action 10/82 - 9/90 6.850 N.A. N.A. Administrative Action 10/90 - 9/94 8.000 N.A. N.A. Administrative Action 10/94 - Present Installments N.A. N.A. Note: The Provo River Project sells energy only. As of October 1994, customers pay all OM&R expenses and in return, receive all the energy produced by the Project.

398

High-Frame-Rate Oil Film Interferometry  

E-Print Network [OSTI]

The fluid dynamics video to which this abstract relates contains visualization of the response of a laminar boundary layer to a sudden puff from a small hole. The boundary layer develops on a flat plate in a wind tunnel; the hole is located at a streamwise Reynolds number of 100,000. The visualization of the boundary layer response is accomplished using interferometry of a transparent, thin film of oil placed on the surface immediately downstream of the hole and with its leading edge perpendicular to the direction of flow. Through lubrication theory, it is understood that the rate of change of the spacing of the interference fringes is proportional to the skin friction at any instant. For reference, a small disk-shaped protrusion of the type often used to trip the boundary layer in wind model tunnel testing is also shown. Three cases with different puff strengths are included. Using a high-speed commercial camera, frame rates in excess of 1000/sec have been recorded; the video shown here was taken at 24 frame...

White, Jonathan C; Chen, John

2010-01-01T23:59:59.000Z

399

Alternative Fuels Data Center: E85 Tax Rate and Definition  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

E85 Tax Rate and E85 Tax Rate and Definition to someone by E-mail Share Alternative Fuels Data Center: E85 Tax Rate and Definition on Facebook Tweet about Alternative Fuels Data Center: E85 Tax Rate and Definition on Twitter Bookmark Alternative Fuels Data Center: E85 Tax Rate and Definition on Google Bookmark Alternative Fuels Data Center: E85 Tax Rate and Definition on Delicious Rank Alternative Fuels Data Center: E85 Tax Rate and Definition on Digg Find More places to share Alternative Fuels Data Center: E85 Tax Rate and Definition on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type E85 Tax Rate and Definition The minimum motor vehicle fuel tax rate on E85 is $0.17 per gallon, compared to the conventional motor fuel tax rate of $0.24 per gallon. E85

400

2007 Wholesale Power Rate Case Initial Proposal : Direct Testimony.  

SciTech Connect (OSTI)

The purpose of our testimony is to sponsor the rate design portions of Bonneville Power Administration's (BPA) Wholesale Power Rate Development Study (WPRDS), WP-07-E-BPA-05, and associated portions of the Wholesale Power Rate Schedules and GRSPs (WP-07-E-BPA-07). Our testimony is organized in eight sections. The first section outlines the purpose of our testimony. Section 2 describes BPA's Demand Rates, including subsections on the definition of the Demand Rate, the method for computing the Demand Rates, and differences from the currently effective WP-02 Demand Rate. Section 3 describes BPA's Load Variance Rate, with subsections on the definition and purpose of the Load Variance Rate, application of the Load Variance Rate, how the Load Variance Rate is calculated, and the differences from the WP-02 Load Variance Rate. Section 4 describes the steps involved in developing BPA's energy rates and differences from the WP-02 rate case. Section 5 discusses discontinuation of the Stepped Up Multi-Year Block Rate. Section 6 describes a minor change to the Unauthorized Increase Rates and the Excess Factoring Rates. Section 7 describes the Targeted Adjustment Charge. Section 8 addresses the Operating Reserves Credit.

United States. Bonneville Power Administration.

2005-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "kv rating mva" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

25 kV Superconducting Fault Current Limiter  

Science Journals Connector (OSTI)

Our technological progress in die field of superconductivity over the last ten years made possible the manufacture of industrial lengths of conductors, consisting of NbTi ultra-fine filaments, embedded in a Cu-30...

T. Verhaege; J. P. Tavergnier; A. Février…

1990-01-01T23:59:59.000Z

402

500 kV transmission line design and fault analysis.  

E-Print Network [OSTI]

??To be able to keep up with energy demands new transmission lines need to be designed and built. Design and planning is a long process… (more)

Haskovic, Mensur

2012-01-01T23:59:59.000Z

403

Utility Rate | OpenEI Community  

Open Energy Info (EERE)

clean energy clean energy Type Term Title Author Replies Last Post sort icon Blog entry clean energy Nominations open for $250,000 Multimedia Clean Energy prizes Graham7781 2 Oct 2012 - 13:01 Groups Menu You must login in order to post into this group. Recent content There is currently no way to s... ranking of utilities by demand charge? FYI, OpenEI now accommodates t... Very useful information. Thank... The utility rate database version 1 API is now deprecated more Group members (28) Managers: Dloomis Rmckeel Sfomail Recent members: MSiira Apin101 Lissacoffey Denizurla Bazouing Gdavis Shehant Anapettirossi Abkatzman BijouLulla Vbugnion Marklane Cbonsig Verdel3c Wisconsin Weatherall Windows Payne Nlong Wzeng 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load)

404

Utility Rate | OpenEI Community  

Open Energy Info (EERE)

dataset dataset Type Term Title Author Replies Last Post sort icon Blog entry dataset Commercial and Residential Hourly Load Data Now Available on OpenEI! Sfomail 17 May 2013 - 12:03 Groups Menu You must login in order to post into this group. Recent content FYI, OpenEI now accommodates t... Very useful information. Thank... The utility rate database version 1 API is now deprecated Glad I could help get you on t... Nick, Thanks very much! That... more Group members (25) Managers: Dloomis Rmckeel Sfomail Recent members: Denizurla Bazouing Gdavis Shehant Anapettirossi Abkatzman BijouLulla Vbugnion Marklane Cbonsig Verdel3c Wisconsin Weatherall Windows Payne Nlong Wzeng Nsbowde Rmbot Ewilson 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation:

405

Utility Rate | OpenEI Community  

Open Energy Info (EERE)

commercial load commercial load Type Term Title Author Replies Last Post sort icon Blog entry commercial load Commercial and Residential Hourly Load Data Now Available on OpenEI! Sfomail 17 May 2013 - 12:03 Groups Menu You must login in order to post into this group. Recent content FYI, OpenEI now accommodates t... Very useful information. Thank... The utility rate database version 1 API is now deprecated Glad I could help get you on t... Nick, Thanks very much! That... more Group members (25) Managers: Dloomis Rmckeel Sfomail Recent members: Denizurla Bazouing Gdavis Shehant Anapettirossi Abkatzman BijouLulla Vbugnion Marklane Cbonsig Verdel3c Wisconsin Weatherall Windows Payne Nlong Wzeng Nsbowde Rmbot Ewilson 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load)

406

Utility Rate | OpenEI Community  

Open Energy Info (EERE)

datasets datasets Type Term Title Author Replies Last Post sort icon Blog entry datasets Commercial and Residential Hourly Load Data Now Available on OpenEI! Sfomail 17 May 2013 - 12:03 Groups Menu You must login in order to post into this group. Recent content FYI, OpenEI now accommodates t... Very useful information. Thank... The utility rate database version 1 API is now deprecated Glad I could help get you on t... Nick, Thanks very much! That... more Group members (25) Managers: Dloomis Rmckeel Sfomail Recent members: Denizurla Bazouing Gdavis Shehant Anapettirossi Abkatzman BijouLulla Vbugnion Marklane Cbonsig Verdel3c Wisconsin Weatherall Windows Payne Nlong Wzeng Nsbowde Rmbot Ewilson 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation:

407

Utility Rate | OpenEI Community  

Open Energy Info (EERE)

Global Atlas Global Atlas Type Term Title Author Replies Last Post sort icon Blog entry Global Atlas IRENA launches global atlas of renewable energy potential Graham7781 11 Feb 2013 - 15:18 Groups Menu You must login in order to post into this group. Recent content FYI, OpenEI now accommodates t... Very useful information. Thank... The utility rate database version 1 API is now deprecated Glad I could help get you on t... Nick, Thanks very much! That... more Group members (25) Managers: Dloomis Rmckeel Sfomail Recent members: Denizurla Bazouing Gdavis Shehant Anapettirossi Abkatzman BijouLulla Vbugnion Marklane Cbonsig Verdel3c Wisconsin Weatherall Windows Payne Nlong Wzeng Nsbowde Rmbot Ewilson 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation:

408

Utility Rate | OpenEI Community  

Open Energy Info (EERE)

electric load data electric load data Type Term Title Author Replies Last Post sort icon Blog entry electric load data Commercial and Residential Hourly Load Data Now Available on OpenEI! Sfomail 17 May 2013 - 12:03 Groups Menu You must login in order to post into this group. Recent content FYI, OpenEI now accommodates t... Very useful information. Thank... The utility rate database version 1 API is now deprecated Glad I could help get you on t... Nick, Thanks very much! That... more Group members (25) Managers: Dloomis Rmckeel Sfomail Recent members: Denizurla Bazouing Gdavis Shehant Anapettirossi Abkatzman BijouLulla Vbugnion Marklane Cbonsig Verdel3c Wisconsin Weatherall Windows Payne Nlong Wzeng Nsbowde Rmbot Ewilson 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load)

409

Utility Rate | OpenEI Community  

Open Energy Info (EERE)

load data load data Type Term Title Author Replies Last Post sort icon Blog entry building load data Commercial and Residential Hourly Load Data Now Available on OpenEI! Sfomail 17 May 2013 - 12:03 Groups Menu You must login in order to post into this group. Recent content FYI, OpenEI now accommodates t... Very useful information. Thank... The utility rate database version 1 API is now deprecated Glad I could help get you on t... Nick, Thanks very much! That... more Group members (25) Managers: Dloomis Rmckeel Sfomail Recent members: Denizurla Bazouing Gdavis Shehant Anapettirossi Abkatzman BijouLulla Vbugnion Marklane Cbonsig Verdel3c Wisconsin Weatherall Windows Payne Nlong Wzeng Nsbowde Rmbot Ewilson 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load)

410

Utility Rate | OpenEI Community  

Open Energy Info (EERE)

Energy Visions Prize Energy Visions Prize Type Term Title Author Replies Last Post sort icon Blog entry Energy Visions Prize Nominations open for $250,000 Multimedia Clean Energy prizes Graham7781 2 Oct 2012 - 13:01 Groups Menu You must login in order to post into this group. Recent content FYI, OpenEI now accommodates t... Very useful information. Thank... The utility rate database version 1 API is now deprecated Glad I could help get you on t... Nick, Thanks very much! That... more Group members (25) Managers: Dloomis Rmckeel Sfomail Recent members: Denizurla Bazouing Gdavis Shehant Anapettirossi Abkatzman BijouLulla Vbugnion Marklane Cbonsig Verdel3c Wisconsin Weatherall Windows Payne Nlong Wzeng Nsbowde Rmbot Ewilson 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load)

411

Utility Rate | OpenEI Community  

Open Energy Info (EERE)

load load Type Term Title Author Replies Last Post sort icon Blog entry building load Commercial and Residential Hourly Load Data Now Available on OpenEI! Sfomail 17 May 2013 - 12:03 Groups Menu You must login in order to post into this group. Recent content FYI, OpenEI now accommodates t... Very useful information. Thank... The utility rate database version 1 API is now deprecated Glad I could help get you on t... Nick, Thanks very much! That... more Group members (25) Managers: Dloomis Rmckeel Sfomail Recent members: Denizurla Bazouing Gdavis Shehant Anapettirossi Abkatzman BijouLulla Vbugnion Marklane Cbonsig Verdel3c Wisconsin Weatherall Windows Payne Nlong Wzeng Nsbowde Rmbot Ewilson 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation:

412

Rate Schedule CV-NWT5  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

NWT5 NWT5 (Supersedes Schedule CV-NWT4) UNITED STATES DEPARTMENT OF ENERGY WESTERN AREA POWER ADMINISTRATION CENTRAL VALLEY PROJECT SCHEDULE OF RATE FOR NETWORK INTEGRATION TRANSMISSION SERVICE Effective: October 1, 2011, through September 30, 2016. Available: Within the marketing area served by the Western Area Power Administration (Western), Sierra Nevada Customer Service Region. Applicable: To customers receiving Central Valley Project (CVP) Network Integration Transmission Service (NITS). Character and Conditions of Service: Transmission service for three-phase, alternating current at 60-hertz, delivered and metered at the voltages and points of delivery or receipt, adjusted for losses, and delivered to points of delivery. This service includes scheduling and system control and dispatch service needed to

413

Rate Schedule COTP-T3  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

COTP-T3 COTP-T3 (Supersedes Schedule COTP-T2) UNITED STATES DEPARTMENT OF ENERGY WESTERN AREA POWER ADMINISTRATION CALIFORNIA-OREGON TRANSMISSION PROJECT SCHEDULE OF RATE FOR POINT-TO-POINT TRANSMISSION SERVICE Effective: October 1, 2011, through September 30, 2016. Available: Within the marketing area served by the Western Area Power Administration (Western), Sierra Nevada Customer Service Region. Applicable: To customers receiving California-Oregon Transmission Project (COTP) firm and/or non-firm point-to-point (PTP) transmission service. Character and Conditions of Service: Transmission service for three-phase, alternating current at 60-hertz, delivered and metered at the voltages and points of delivery or receipt, adjusted for losses, and delivered to points of

414

Rate Schedule CV-F13  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

F13 F13 (Supersedes Schedule CV-F12) UNITED STATES DEPARTMENT OF ENERGY WESTERN AREA POWER ADMINISTRATION CENTRAL VALLEY PROJECT SCHEDULE OF RATES FOR BASE RESOURCE AND FIRST PREFERENCE POWER Effective: October 1, 2011, through September 30, 2016. Available: Within the marketing area served by the Western Area Power Administration (Western), Sierra Nevada Customer Service Region. Applicable: To the Base Resource (BR) and First Preference (FP) Power Customers. Character and Conditions of Service: Alternating current, 60-hertz, three-phase, delivered and metered at the voltages and points established by contract. This service includes the Central Valley Project (CVP) transmission (to include reactive supply and voltage control from Federal generation sources needed to support

415

Rate Schedule CV-TPT7  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

TPT7 TPT7 (Supersedes Schedule CV-TPT6) UNITED STATES DEPARTMENT OF ENERGY WESTERN AREA POWER ADMINISTRATION CENTRAL VALLEY PROJECT SCHEDULE OF RATE FOR TRANSMISSION OF WESTERN POWER BY OTHERS Effective: October 1, 2011, through September 30, 2016. Available: Within the marketing area served by the Western Area Power Administration (Western), Sierra Nevada Customer Service Region. Applicable: To Western's power service customers who require transmission service by a third party to receive power sold by Western. Character and Conditions of Service: Transmission service for three-phase, alternating current at 60-hertz, delivered and metered at the voltages and points of delivery or receipt, adjusted for losses, and delivered to points as

416

Utility Rate | OpenEI Community  

Open Energy Info (EERE)

DOE DOE Type Term Title Author Replies Last Post sort icon Blog entry DOE FOA aimed at growing expansive database of Renewable Energy and Energy Efficiency Incentives and Policies Graham7781 12 Dec 2012 - 11:30 Groups Menu You must login in order to post into this group. Recent content There is currently no way to s... ranking of utilities by demand charge? FYI, OpenEI now accommodates t... Very useful information. Thank... The utility rate database version 1 API is now deprecated more Group members (28) Managers: Dloomis Rmckeel Sfomail Recent members: MSiira Apin101 Lissacoffey Denizurla Bazouing Gdavis Shehant Anapettirossi Abkatzman BijouLulla Vbugnion Marklane Cbonsig Verdel3c Wisconsin Weatherall Windows Payne Nlong Wzeng 429 Throttled (bot load) Error 429 Throttled (bot load)

417

Utility Rate | OpenEI Community  

Open Energy Info (EERE)

FOA FOA Type Term Title Author Replies Last Post sort icon Blog entry FOA FOA aimed at growing expansive database of Renewable Energy and Energy Efficiency Incentives and Policies Graham7781 12 Dec 2012 - 11:30 Groups Menu You must login in order to post into this group. Recent content FYI, OpenEI now accommodates t... Very useful information. Thank... The utility rate database version 1 API is now deprecated Glad I could help get you on t... Nick, Thanks very much! That... more Group members (25) Managers: Dloomis Rmckeel Sfomail Recent members: Denizurla Bazouing Gdavis Shehant Anapettirossi Abkatzman BijouLulla Vbugnion Marklane Cbonsig Verdel3c Wisconsin Weatherall Windows Payne Nlong Wzeng Nsbowde Rmbot Ewilson 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load)

418

Utility Rate | OpenEI Community  

Open Energy Info (EERE)

Incentives and Policies Incentives and Policies Type Term Title Author Replies Last Post sort icon Blog entry Incentives and Policies Semantic Mediawiki Semantic Forms update Rmckeel 22 Oct 2012 - 07:23 Groups Menu You must login in order to post into this group. Recent content FYI, OpenEI now accommodates t... Very useful information. Thank... The utility rate database version 1 API is now deprecated Glad I could help get you on t... Nick, Thanks very much! That... more Group members (25) Managers: Dloomis Rmckeel Sfomail Recent members: Denizurla Bazouing Gdavis Shehant Anapettirossi Abkatzman BijouLulla Vbugnion Marklane Cbonsig Verdel3c Wisconsin Weatherall Windows Payne Nlong Wzeng Nsbowde Rmbot Ewilson 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation:

419

Viscosity in the escape-rate formalism  

Science Journals Connector (OSTI)

We apply the escape-rate formalism to compute the shear viscosity in terms of the chaotic properties of the underlying microscopic dynamics. A first-passage problem is set up for the escape of the Helfand moment associated with viscosity out of an interval delimited by absorbing boundaries. At the microscopic level of description, the absorbing boundaries generate a fractal repeller. The fractal dimensions of this repeller are directly related to the shear viscosity and the Lyapunov exponent, which allows us to compute its values. We apply this method to the Bunimovich-Spohn minimal model of viscosity which is composed of two hard disks in elastic collision on a torus. These values are in excellent agreement with the values obtained by other methods such as the Green-Kubo and Einstein-Helfand formulas.

S. Viscardy and P. Gaspard

2003-10-23T23:59:59.000Z

420

Adjustable flow rate controller for polymer solutions  

DOE Patents [OSTI]

An adjustable device for controlling the flow rate of polymer solutions which results in only little shearing of the polymer molecules, said device comprising an inlet manifold, an outlet manifold, a plurality of tubes capable of providing communication between said inlet and outlet manifolds, said tubes each having an internal diameter that is smaller than that of the inlet manifold and large enough to insure that viscosity of the polymer solution passing through each said tube will not be reduced more than about 25 percent, and a valve associated with each tube, said valve being capable of opening or closing communication in that tube between the inlet and outlet manifolds, each said valve when fully open having a diameter that is substantially at least as great as that of the tube with which it is associated.

Jackson, Kenneth M. (Bartlesville, OK)

1981-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "kv rating mva" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Mutual information rate and bounds for it  

E-Print Network [OSTI]

The amount of information exchanged per unit of time between two nodes in a dynamical network or between two data sets is a powerful concept for analysing complex systems. This quantity, known as the mutual information rate (MIR), is calculated from the mutual information, which is rigorously defined only for random systems. Moreover, the definition of mutual information is based on probabilities of significant events. This work offers a simple alternative way to calculate the MIR in dynamical (deterministic) networks or between two data sets (not fully deterministic), and to calculate its upper and lower bounds without having to calculate probabilities, but rather in terms of well known and well defined quantities in dynamical systems. As possible applications of our bounds, we study the relationship between synchronisation and the exchange of information in a system of two coupled maps and in experimental networks of coupled oscillators.

M. S. Baptista; R. M. Rubinger; E. R. V. Junior; J. C. Sartorelli; U. Parlitz; C. Grebogi

2011-04-18T23:59:59.000Z

422

On Star Formation Rates in Dwarf Galaxies  

E-Print Network [OSTI]

We present evolutionary synthesis models of starbursts on top of old stellar populations to investigate in detailed time evolution the relation between Ha luminosity and star formation rate (SFR). The models show that several effects have an impact on the ratio between L(Ha) and SFR. Metallicity different from solar abundance, a time delay between star formation and maximum Ha-luminosity, and a varying stellar initial mass function give rise to strong variations in the ratio of Ha luminosity to SFR and can cause large errors in the determination of the SFR when employing well-known calibrations. When studying star-bursting dwarf galaxies, and sub-galactic fragments at high redshift, which show SFR fluctuating on short timescales, these effects can add up to errors of two orders of magnitude compared with the calibrations. To accurately determine the true current SFR additional data in combination with models for the spectral energy distribution are needed.

Peter M. Weilbacher; Uta Fritze-v. Alvensleben

2001-05-16T23:59:59.000Z

423

Rate Schedule CV-EID4  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

EID4 EID4 (Supersedes Schedule CV-EID3) UNITED STATES DEPARTMENT OF ENERGY WESTERN AREA POWER ADMINISTRATION CENTRAL VALLEY PROJECT SCHEDULE OF RATE FOR ENERGY IMBALANCE SERVICE Effective: October 1, 2011, through September 30, 2016. Available: Within the marketing area served by the Western Area Power Administration (Western), Sierra Nevada Customer Service Region. Applicable: To customers receiving Energy Imbalance (EI) service. Character and Conditions of Service: EI is provided when a difference occurs between the scheduled and the actual delivery of energy to a load within the Sub-Balancing Authority (SBA) over an hour or in accordance with approved policies and procedures. The deviation, in megawatts, is the net scheduled amount of

424

Utility Rate | OpenEI Community  

Open Energy Info (EERE)

funding funding Type Term Title Author Replies Last Post sort icon Blog entry funding FOA aimed at growing expansive database of Renewable Energy and Energy Efficiency Incentives and Policies Graham7781 12 Dec 2012 - 11:30 Groups Menu You must login in order to post into this group. Recent content FYI, OpenEI now accommodates t... Very useful information. Thank... The utility rate database version 1 API is now deprecated Glad I could help get you on t... Nick, Thanks very much! That... more Group members (25) Managers: Dloomis Rmckeel Sfomail Recent members: Denizurla Bazouing Gdavis Shehant Anapettirossi Abkatzman BijouLulla Vbugnion Marklane Cbonsig Verdel3c Wisconsin Weatherall Windows Payne Nlong Wzeng Nsbowde Rmbot Ewilson 429 Throttled (bot load) Error 429 Throttled (bot load)

425

Reverse-Engineering Banks' Financial Strength Ratings Using ...  

E-Print Network [OSTI]

Dec 27, 2006 ... reverse-engineering a superior bank rating system, which turns out to ...... sector (

mal92

2009-05-16T23:59:59.000Z

426

Workshop on Thermonuclear Reaction Rates for Astrophysics Applications  

E-Print Network [OSTI]

Workshop on Thermonuclear Reaction Rates for Astrophysics Applications 24-25 November 2011, Athens circular for the Workshop on Thermonuclear Reaction Rates for Astrophysics Applications, to be held of thermonuclear reaction rates. The topics of the workshop, in relation with thermonuclear reaction rates

427

The Halo Formation Rate and its link to the Global Star Formation Rate  

E-Print Network [OSTI]

The star formation history of the universe shows strong evolution with cosmological epoch. Although we know mergers between galaxies can cause luminous bursts of star formation, the relative importance of such mergers to the global star formation rate (SFR) is unknown. We present a simple analytic formula for the rate at which halos merge to form higher-mass systems, derived from Press-Schechter theory and confirmed by numerical simulations (for high halo masses). A comparison of the evolution in halo formation rate with the observed evolution in the global SFR indicates that the latter is largely driven by halo mergers at z>1. Recent numerical simulations by Kolatt et al. (1999) and Knebe & Muller (1999) show how merging systems are strongly biased tracers of mass fluctuations, thereby explaining the strong clustering observed for Lyman-break galaxies without any need to assume that Lyman-break galaxies are associated only with the most massive systems at z~3.

W. J. Percival; L. Miller; W. E. Ballinger

1999-09-15T23:59:59.000Z

428

In-cell reaction rate distributions and cell-average reaction rates in fast critical assemblies  

SciTech Connect (OSTI)

Measurements are described for determining average values of fission rates in /sup 235/U, /sup 238/U and /sup 239/Pu and capture rates in /sup 238/U for heterogeneous cells used to construct fast critical assemblies. The measurements are based on irradiations of foils of /sup 238/U, /sup 235/U and /sup 239/Pu with counting of fission and capture products using gamma-ray spectroscopy. Both plate and pin cells are considered. Procedures are described for inferring cell-average reaction rate values from a single foil location based on a cell using a quantity called a cell factor. Cell factors are determined from special measurements in which several foils are irradiated within a cell. Comparisons are presented between cell factors determined by measurements and by Monte Carlo calculations which lend credibility to the measurement procedures.

Brumbach, S.B.; Gasidlo, J.M.

1985-08-01T23:59:59.000Z

429

Alternative Fuels Data Center: Ethanol Fuel Blend Tax Rate  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Ethanol Fuel Blend Tax Ethanol Fuel Blend Tax Rate to someone by E-mail Share Alternative Fuels Data Center: Ethanol Fuel Blend Tax Rate on Facebook Tweet about Alternative Fuels Data Center: Ethanol Fuel Blend Tax Rate on Twitter Bookmark Alternative Fuels Data Center: Ethanol Fuel Blend Tax Rate on Google Bookmark Alternative Fuels Data Center: Ethanol Fuel Blend Tax Rate on Delicious Rank Alternative Fuels Data Center: Ethanol Fuel Blend Tax Rate on Digg Find More places to share Alternative Fuels Data Center: Ethanol Fuel Blend Tax Rate on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Ethanol Fuel Blend Tax Rate The tax rate on fuel containing ethanol is $0.06 per gallon less than the tax rate on other motor fuels in certain geographic areas. This reduced

430

The relationship of metabolic rate to rate of gain in young beef cattle  

E-Print Network [OSTI]

reaches maturity. %1th tl ls ln mind, an attempt has been made to determine whether metabolic rat;e has any relationship to rate of gain ln young beef cattle. REVIEVi OF LITERATVRE It is generally known that the thyroid gland has an impoztant... that of the thyroidoctomized animal decreased to about 1300 calories per square . . . etor pcr day at tho age o'f eight morths, at wi;1ch level it re- mained dto age forty months. The volu. . . e of air inhaled pe. minute is less in t?ie thyroidectomized ar. i. . . al...

Burns, Kenneth Harold

2012-06-07T23:59:59.000Z

431

Property:OpenEI/UtilityRate/DemandRateStructure/Tier6Adjustment | Open  

Open Energy Info (EERE)

Property Property Edit with form History Facebook icon Twitter icon » Property:OpenEI/UtilityRate/DemandRateStructure/Tier6Adjustment Jump to: navigation, search This is a property of type Number. Pages using the property "OpenEI/UtilityRate/DemandRateStructure/Tier6Adjustment" Showing 13 pages using this property. 4 4b524791-bef2-49b1-850b-458730755203 + 8 + 4b524791-bef2-49b1-850b-458730755203 + 8 +, 9 +, 67 +, ... 4b524791-bef2-49b1-850b-458730755203 + 9 + 4b524791-bef2-49b1-850b-458730755203 + 2 + 4b524791-bef2-49b1-850b-458730755203 + 67 + 4b524791-bef2-49b1-850b-458730755203 + 2 + 4b524791-bef2-49b1-850b-458730755203 + 89 + 4b524791-bef2-49b1-850b-458730755203 + 3 + 4b524791-bef2-49b1-850b-458730755203 + 3 + 4b524791-bef2-49b1-850b-458730755203 + 3 +

432

Property:OpenEI/UtilityRate/EnergyRateStructure/Period | Open Energy  

Open Energy Info (EERE)

Property Property Edit with form History Facebook icon Twitter icon » Property:OpenEI/UtilityRate/EnergyRateStructure/Period Jump to: navigation, search This is a property of type Number. The allowed values for this property are: 1 2 3 4 5 6 7 8 9 Pages using the property "OpenEI/UtilityRate/EnergyRateStructure/Period" Showing 25 pages using this property. (previous 25) (next 25) 0 000b6dfa-a541-428a-9029-423006e22a34 + 1 +, 2 + 000b6dfa-a541-428a-9029-423006e22a34 + 1 + 000b6dfa-a541-428a-9029-423006e22a34 + 2 + 000e60f7-120d-48ab-a1f9-9c195329c628 + 1 + 000e60f7-120d-48ab-a1f9-9c195329c628 + 1 + 001361ca-50d2-49bc-b331-08755a2c7c7d + 1 + 001361ca-50d2-49bc-b331-08755a2c7c7d + 1 + 0016f771-cda9-4312-afc2-63f10c8d8bf5 + 1 + 0016f771-cda9-4312-afc2-63f10c8d8bf5 + 1 +

433

Elevated CO2 affects shell dissolution rate but not calcification rate in a marine snail  

Science Journals Connector (OSTI)

...Research articles 1001 60 69 70 Elevated CO2 affects shell dissolution rate but not calcification...authors contributed equally to this work. As CO2 levels increase in the atmosphere, so too...Although direct effects of moderately elevated CO2 in sea water may be of little consequence...

2010-01-01T23:59:59.000Z

434

ANALYTICAL STAR FORMATION RATE FROM GRAVOTURBULENT FRAGMENTATION  

SciTech Connect (OSTI)

We present an analytical determination of the star formation rate (SFR) in molecular clouds, based on a time-dependent extension of our analytical theory of the stellar initial mass function. The theory yields SFRs in good agreement with observations, suggesting that turbulence is the dominant, initial process responsible for star formation. In contrast to previous SFR theories, the present one does not invoke an ad hoc density threshold for star formation; instead, the SFR continuously increases with gas density, naturally yielding two different characteristic regimes, thus two different slopes in the SFR versus gas density relationship, in agreement with observational determinations. Besides the complete SFR derivation, we also provide a simplified expression, which reproduces the complete calculations reasonably well and can easily be used for quick determinations of SFRs in cloud environments. A key property at the heart of both our complete and simplified theory is that the SFR involves a density-dependent dynamical time, characteristic of each collapsing (prestellar) overdense region in the cloud, instead of one single mean or critical freefall timescale. Unfortunately, the SFR also depends on some ill-determined parameters, such as the core-to-star mass conversion efficiency and the crossing timescale. Although we provide estimates for these parameters, their uncertainty hampers a precise quantitative determination of the SFR, within less than a factor of a few.

Hennebelle, Patrick [Laboratoire de Radioastronomie, UMR CNRS 8112, Ecole Normale Superieure et Observatoire de Paris, 24 rue Lhomond, 75231 Paris Cedex 05 (France); Chabrier, Gilles [Ecole Normale Superieure de Lyon, CRAL, UMR CNRS 5574, 69364 Lyon Cedex 07 (France)

2011-12-20T23:59:59.000Z

435

Solids flow rate measurement in dense slurries  

SciTech Connect (OSTI)

Accurate and rapid flow rate measurement of solids in dense slurries remains an unsolved technical problem, with important industrial applications in chemical processing plants and long-distance solids conveyance. In a hostile two-phase medium, such a measurement calls for two independent parameter determinations, both by non-intrusive means. Typically, dense slurries tend to flow in laminar, non-Newtonian mode, eliminating most conventional means that usually rely on calibration (which becomes more difficult and costly for high pressure and temperature media). These issues are reviewed, and specific solutions are recommended in this report. Detailed calculations that lead to improved measuring device designs are presented for both bulk density and average velocity measurements. Cross-correlation, chosen here for the latter task, has long been too inaccurate for practical applications. The cause and the cure of this deficiency are discussed using theory-supported modeling. Fluid Mechanics are used to develop the velocity profiles of laminar non-Newtonian flow in a rectangular duct. This geometry uniquely allows the design of highly accurate `capacitive` devices and also lends itself to gamma transmission densitometry on an absolute basis. An absolute readout, though of less accuracy, is also available from a capacitive densitometer and a pair of capacitive sensors yields signals suitable for cross-correlation velocity measurement.

Porges, K.G.; Doss, E.D.

1993-09-01T23:59:59.000Z

436

Definition: Dynamic Capability Rating System | Open Energy Information  

Open Energy Info (EERE)

Capability Rating System Capability Rating System Jump to: navigation, search Dictionary.png Dynamic Capability Rating System Dynamic capability rating adjusts the thermal rating of power equipment based on factors such as air temperature, wind speed, and solar radiation to reflect actual operating conditions. These systems are primarily used on high capacity or critical power system elements such as transmission lines and large power transformers.[1] Related Terms transmission lines, Dynamic capability rating, thermal rating, power, solar radiation, rating, transmission line, transformer References ↑ https://www.smartgrid.gov/category/technology/dynamic_capability_rating_system [[Category LikeLike UnlikeLike You like this.Sign Up to see what your friends like. : Smart Grid Definitions|Template:BASEPAGENAME]]

437

Alternative Fuels Data Center: Alternative Fuel Tax Rates  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Alternative Fuel Tax Alternative Fuel Tax Rates to someone by E-mail Share Alternative Fuels Data Center: Alternative Fuel Tax Rates on Facebook Tweet about Alternative Fuels Data Center: Alternative Fuel Tax Rates on Twitter Bookmark Alternative Fuels Data Center: Alternative Fuel Tax Rates on Google Bookmark Alternative Fuels Data Center: Alternative Fuel Tax Rates on Delicious Rank Alternative Fuels Data Center: Alternative Fuel Tax Rates on Digg Find More places to share Alternative Fuels Data Center: Alternative Fuel Tax Rates on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Alternative Fuel Tax Rates Blended fuels that contain at least 10% gasoline or diesel are taxed at the full tax rates of gasoline ($0.30 per gallon) or diesel ($0.312 per

438

Alternative Fuels Data Center: Alternative Fuel Tax Rates  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Alternative Fuel Tax Alternative Fuel Tax Rates to someone by E-mail Share Alternative Fuels Data Center: Alternative Fuel Tax Rates on Facebook Tweet about Alternative Fuels Data Center: Alternative Fuel Tax Rates on Twitter Bookmark Alternative Fuels Data Center: Alternative Fuel Tax Rates on Google Bookmark Alternative Fuels Data Center: Alternative Fuel Tax Rates on Delicious Rank Alternative Fuels Data Center: Alternative Fuel Tax Rates on Digg Find More places to share Alternative Fuels Data Center: Alternative Fuel Tax Rates on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Alternative Fuel Tax Rates A special excise tax rate of 2% is imposed on the sale of propane (liquefied petroleum gas) and a tax of $0.04 per gallon is imposed on all

439

Flow Rate Estimates Qs and As Q: What is the Flow Rate Technical Group?  

E-Print Network [OSTI]

to the BP oil spill in the Gulf of Mexico be stepped up as a result of the new flow rate estimates released their initial estimate. · The first approach analyzed how much oil is on the surface of the Gulf of Mexico using,000 and 270,000 barrels of oil are on the surface of the Gulf of Mexico and that a similar amount had already

Fleskes, Joe

440

TFTR neutral-beam power system  

SciTech Connect (OSTI)

The TFTR Neutral Beam Power System (NBPS) consists of the accelerator grid power supply and the auxiliary power supplies required to operate the TFTR 120-keV ion sources. The current configuration of the NBPS including the 11-MVA accelerator grid power supply and the Arc and Filament power supplies isolated for operation at accelerator grid voltages up to 120 kV, is described. The prototype NBPS has been assembled at the Princeton Plasma Physics Laboratory and has been operated. The results of the initial operation and the description and resolution of some of the technical problems encountered during the commissioning tests are presented.

Winje, R.A.

1982-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "kv rating mva" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Energy Performance Ratings for Windows, Doors, and Skylights | Department  

Broader source: Energy.gov (indexed) [DOE]

Energy Performance Ratings for Windows, Doors, and Skylights Energy Performance Ratings for Windows, Doors, and Skylights Energy Performance Ratings for Windows, Doors, and Skylights June 18, 2012 - 9:35am Addthis Before you shop for energy-efficient windows, doors, and skylights, learn about energy performance ratings. | Photo courtesy of iStockphoto.com/JamesBrey. Before you shop for energy-efficient windows, doors, and skylights, learn about energy performance ratings. | Photo courtesy of iStockphoto.com/JamesBrey. What does this mean for me? Energy performance ratings make it easier for you to purchase the window most appropriate for your home's climate and orientation. Using energy performance ratings, you can fine-tune window placement in your home. You can use the energy performance ratings of windows, doors, and skylights

442

ALA-1-N Wholesale Power Rate Schedule | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

ALA-1-N Wholesale Power Rate Schedule ALA-1-N Wholesale Power Rate Schedule ALA-1-N Wholesale Power Rate Schedule Area: PowerSouth Energy Cooperative System: Georgia-Alabama-South Carolina This rate schedule shall be available to the PowerSouth Energy Cooperative. This rate schedule shall be applicable to power and accompanying energy generated at the Allatoona, Buford, J. Strom Thurmond, Walter F. George, Hartwell, Millers Ferry, West Point, Robert F. Henry, Carters, and Richard B. Russell Projects and sold under contract between the Cooperative and the Government. This rate schedule does not apply to energy from pumping operations at the Carters and Richard B. Russell Projects. Document Available for Download ALA-1-N Rate Schedule More Documents & Publications MISS-1-N Wholesale Power Rate Schedule

443

Alternative Fuels Data Center: Alternative Fuel Tax Rate  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Alternative Fuel Tax Alternative Fuel Tax Rate to someone by E-mail Share Alternative Fuels Data Center: Alternative Fuel Tax Rate on Facebook Tweet about Alternative Fuels Data Center: Alternative Fuel Tax Rate on Twitter Bookmark Alternative Fuels Data Center: Alternative Fuel Tax Rate on Google Bookmark Alternative Fuels Data Center: Alternative Fuel Tax Rate on Delicious Rank Alternative Fuels Data Center: Alternative Fuel Tax Rate on Digg Find More places to share Alternative Fuels Data Center: Alternative Fuel Tax Rate on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Alternative Fuel Tax Rate A distributor of any alternative fuel used to operate an internal combustion engine must pay a license tax of $0.0025 for each gallon of

444

Building Energy Software Tools Directory: REM/Rate  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

REM/Rate REM/Rate REM/Rate logo. User-friendly, yet highly sophisticated, residential energy analysis, code compliance and rating software developed specifically for the needs of HERS providers. REM/Rate calculates heating, cooling, hot water, lighting, and appliance energy loads, consumption and costs for new and existing single and multi-family homes. Climate data is available for cities and towns throughout North America. A home energy rating is calculated based on the proposed DOE HERS guidelines (10 CFR 437) as modified by the RESNET/NASEO HERS Technical Committee. In addition to an energy rating, REM/Rate creates value added information including energy efficiency mortgage report, energy appraisal addendum, energy code compliance (MEC, IECC, and ASHRAE), improvement analysis (existing homes), design optimization (new homes),

445

Analysis of Water Rate Escalations across the United States  

Broader source: Energy.gov (indexed) [DOE]

Analysis of Water Rate Escalations across the United States Analysis of Water Rate Escalations across the United States Elisabeth Giever Kate McMordie Stoughton Susan Loper October 2010 Executive Summary This document provides an overview of an analysis that examined changes in water rates across the country to develop a basic understanding of water rate escalations and how water rates are impacted from outside influences. The analysis investigated how water rates are influenced by the geographic region, water source, and drought tendencies. For example, one observation of the analysis found that cities located in regions of long term drought may have higher escalation rates than cities in water rich environments. Typical escalation rates were found to be between 4 and 8%. This information can be

446

CM-1-H Wholesale Power Rate Schedule | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

CM-1-H Wholesale Power Rate Schedule CM-1-H Wholesale Power Rate Schedule CM-1-H Wholesale Power Rate Schedule Area: MEAM, MDEA, and SMEPA System: CU This rate schedule shall be available to the South Mississippi Electric Power Association, Municipal Energy Agency of Mississippi, and Mississippi Delta Energy Agency. This rate schedule shall be applicable to electric capacity and energy available from the Dale Hollow, Center Hill, Wolf Creek, Cheatham, Old Hickory, Barkley, J. Percy Priest, and Cordell Hull Projects (all of such projects being hereinafter called collectively the "Cumberland Projects") and sold in wholesale quantities. Document Available for Download CM-1-H Rate Schedule More Documents & Publications CEK-1-H Wholesale Power Rate Schedule CSI-1-H Wholesale Power Rate Schedule

447

CM-1-H Wholesale Power Rate Schedule | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

CM-1-H Wholesale Power Rate Schedule CM-1-H Wholesale Power Rate Schedule CM-1-H Wholesale Power Rate Schedule Area: MEAM, MDEA, and SMEPA System: CU This rate schedule shall be available to the South Mississippi Electric Power Association, Municipal Energy Agency of Mississippi, and Mississippi Delta Energy Agency. This rate schedule shall be applicable to electric capacity and energy available from the Dale Hollow, Center Hill, Wolf Creek, Cheatham, Old Hickory, Barkley, J. Percy Priest, and Cordell Hull Projects (all of such projects being hereinafter called collectively the "Cumberland Projects") and sold in wholesale quantities. Document Available for Download CM-1-H Rate Schedule More Documents & Publications CEK-1-H Wholesale Power Rate Schedule CSI-1-H Wholesale Power Rate Schedule

448

Low Cost Gigabit Rate Transmit/Receive Chip Set  

E-Print Network [OSTI]

1 H Low Cost Gigabit Rate Transmit/Receive Chip Set Technical Data Features · Transparent, Extended Ribbon Cable Replacement · Implemented in a Low Cost Aluminum M-Quad 80 Package · High-Speed Serial Rate

California at Santa Cruz, University of

449

Parameter Study on Prediction Methods for TBM Penetration Rate  

Science Journals Connector (OSTI)

Penetration rate prediction of Tunnel Boring Machine (TBM) ... research, influence of effective parameters on TBM penetration rate is investigated by sensitivity analysis of three...TBM.... Based on these analyse...

Mahdi Zoorabadi; Serkan Saydam…

2013-04-01T23:59:59.000Z

450

Solvent Penetration Rate in Tablet Measurement Using Video Image Processing  

Science Journals Connector (OSTI)

We describe a simple technique for the measurement of solvent penetration rates into spray-dried lactose (DCL) tablets ... results of the experimental study show that the penetration rate in some cases appears to...

D. Braido; Y. Gulak; A. Cuitino

2012-06-01T23:59:59.000Z

451

Microsoft Word - News Release -- Rates Initial Proposal Dec ...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

utilities, the Bonneville Power Administration today proposed a 6.7 percent average wholesale power rate increase for the fiscal year 2016-2017 rate period. BPA is also proposing...

452

Rangeland Drought Management for Texans: Stocking Rate and Grazing Management  

E-Print Network [OSTI]

This publication explains how stocking rates and grazing management decisions can help a ranch survive a drought. To deal with drought, a rancher must monitor forage supply and demand; use a conservative stocking rate and keep it flexible...

Hart, Charles R.; Carpenter, Bruce B.

2001-05-03T23:59:59.000Z

453

Failure Rates from Certification Testing to UL and IEC Standards...  

Broader source: Energy.gov (indexed) [DOE]

Failure Rates from Certification Testing to UL and IEC Standards for Flat Plate PV Modules Failure Rates from Certification Testing to UL and IEC Standards for Flat Plate PV...

454

Widget:UtilityRatesByCompany | Open Energy Information  

Open Energy Info (EERE)

Widget Edit History Facebook icon Twitter icon Widget:UtilityRatesByCompany Jump to: navigation, search This widget aids the user in finding utility rates for a given company....

455

Widget:UtilityRateFinder | Open Energy Information  

Open Energy Info (EERE)

Widget Edit History Facebook icon Twitter icon Widget:UtilityRateFinder Jump to: navigation, search This widget aids the user in finding a utility rate. Semantic auto-complete...

456

Generating Facility Rate-Making | Open Energy Information  

Open Energy Info (EERE)

Rate-Making Jump to: navigation, search This article is a stub. You can help OpenEI by expanding it. Retrieved from "http:en.openei.orgwindex.php?titleGeneratingFacilityRate...

457

Zymomonas mobilis Mutants with an Increased Rate of Alcohol Production  

Science Journals Connector (OSTI)

...University of Florida, Gainesville, Florida 32611 Received...retention of higher rates of ethanol production...beverages and fuel, variations...maintenance of higher rates of glycolysis...Department of Energy, Office of...Agriculture, Alcohol Fuels Program. We...

Y. A. Osman; L. O. Ingram

1987-07-01T23:59:59.000Z

458

Heart rate variability in mice with coronary heart disease  

E-Print Network [OSTI]

Heart rate variability (HRV), the beat-to-beat fluctuation of the heart rate, is a non-invasive test that measures the autonomic regulation of the heart. Assessment of HRV has been shown to predict the risk of mortality ...

Zapanta, Laurence (Laurence F.)

2005-01-01T23:59:59.000Z

459

Utility Rate Design Revision - A Frisbee Full of Boomerangs  

E-Print Network [OSTI]

Rising electricity prices have prompted investigation of utility rates and proposals for changed in their design. The purpose of this paper is to discuss the current design of electric rates, changes proposed, actual trends, and predictable results...

Dannenmaier, J. H.

1979-01-01T23:59:59.000Z

460

Alternative Fuels Data Center: Natural Gas Rate and Cost Recovery  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Natural Gas Rate and Natural Gas Rate and Cost Recovery Authorization to someone by E-mail Share Alternative Fuels Data Center: Natural Gas Rate and Cost Recovery Authorization on Facebook Tweet about Alternative Fuels Data Center: Natural Gas Rate and Cost Recovery Authorization on Twitter Bookmark Alternative Fuels Data Center: Natural Gas Rate and Cost Recovery Authorization on Google Bookmark Alternative Fuels Data Center: Natural Gas Rate and Cost Recovery Authorization on Delicious Rank Alternative Fuels Data Center: Natural Gas Rate and Cost Recovery Authorization on Digg Find More places to share Alternative Fuels Data Center: Natural Gas Rate and Cost Recovery Authorization on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type

Note: This page contains sample records for the topic "kv rating mva" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Energy Performance Ratings for Windows, Doors, and Skylights | Department  

Broader source: Energy.gov (indexed) [DOE]

Energy Performance Ratings for Windows, Doors, and Skylights Energy Performance Ratings for Windows, Doors, and Skylights Energy Performance Ratings for Windows, Doors, and Skylights June 18, 2012 - 9:35am Addthis Before you shop for energy-efficient windows, doors, and skylights, learn about energy performance ratings. | Photo courtesy of iStockphoto.com/JamesBrey. Before you shop for energy-efficient windows, doors, and skylights, learn about energy performance ratings. | Photo courtesy of iStockphoto.com/JamesBrey. What does this mean for me? Energy performance ratings make it easier for you to purchase the window most appropriate for your home's climate and orientation. Using energy performance ratings, you can fine-tune window placement in your home. You can use the energy performance ratings of windows, doors, and skylights

462

On the Energy Efficiency of Mixed-Line-Rate Networks  

Science Journals Connector (OSTI)

We present an approach to evaluate energy efficiency of mixed-line-rate (MLR) optical networks. A comparative study of energy efficiency of MLR and single-line-rate (SLR) networks...

Chowdhury, Pulak; Tornatore, Massimo; Mukherjee, Biswanath

463

Application of release rate data to hazard load calculations  

Science Journals Connector (OSTI)

The author illustrates methods of applying heat, smoke and toxic gas release rate data to calculating fire hazard loading values.

Edwin E. Smith

1974-08-01T23:59:59.000Z

464

Size structuring of planktonic communities : biological rates and ecosystem dynamics  

E-Print Network [OSTI]

Bight and central equatorial Pacific show increasing growth rates with size, while those cells measured in the Somali Basin,

Taniguchi, Darcy Anne Akiko

2013-01-01T23:59:59.000Z

465

Minimizing Variation in Outdoor CPV Power Ratings (Presentation)  

SciTech Connect (OSTI)

Module data from NREL's CPV test bed is used to examine methods for calculating outdoor CPV power ratings. IEC 62670 and ASTM E2527 are used as a starting point for determining a module power rating on a monthly basis. Monthly power ratings vary by more than desired using existing methods. The presentation examines modifications to existing methods as well as spectral corrections to reduce variation in monthly module power ratings.

Muller, M.

2011-02-01T23:59:59.000Z

466

Methane oxidation rates in the anaerobic sediments of Saanich Inlet  

Science Journals Connector (OSTI)

water methane concentration were avail- able. ... water solute concentrations and methane oxidation rates ..... Diffusion of light paraffin hydrocarbons in water.

2000-02-09T23:59:59.000Z

467

EXPLAINING OUTCROSSING RATE IN CAMPANULASTRUM AMERICANUM (CAMPANULACEAE): GEITONOGAMY  

E-Print Network [OSTI]

SELF-INCOMPATIBILITY Leah J. Kruszewski and Laura F. Galloway1 Department of Biology, University, the high outcrossing rate could result from cryptic self-incompatibility, a mechanism that favors outcross differential growth rates of self and outcross pollen tubes produce cryptic self-incompatibility. Growth rates

Galloway, Laura F.

468

Rates of superluminous supernovae at z 0.2  

Science Journals Connector (OSTI)

......research-article Article Rates of superluminous supernovae...ACT 2611, Australia 3 Physics Department, University...calculate the volumetric rate of superluminous supernovae...in our unfiltered band pass and may suggest an even...we measure the SLSN-I rate to be about (32 )Gpcyrh......

Robert M. Quimby; Fang Yuan; Carl Akerlof; J. Craig Wheeler

2013-01-01T23:59:59.000Z

469

Comparing infrared star formation rate indicators with optically derived quantities  

Science Journals Connector (OSTI)

......infrared star formation rate indicators with optically...USA 4 School of Physics, Astronomy, and...Spitzer 24-mum band pass and Halpha-measured star formation rate varies from galaxy...Spitzer 8.0-mum band pass, ultraviolet-excited...track star formation rate (SFR; e.g. Calzetti......

J. E. Young; C. Gronwall; J. J. Salzer; J. L. Rosenberg

2014-01-01T23:59:59.000Z

470

On column density thresholds and the star formation rate  

Science Journals Connector (OSTI)

......cloud affect the rate at which stars form...model of the thermal physics of the clouds. However...candidate particle passes a number of tests...shown to reduce the rate of star formation...lower the overall rate of star formation...can capture all the physics required to create......

Paul C. Clark; Simon C. O. Glover

2014-01-01T23:59:59.000Z

471

Ribosome recycling induces optimal translation rate at low ribosomal availability  

Science Journals Connector (OSTI)

...important consequences for the physics of transport of ribosomes...on protein production rates under differing growth...production, fine-tuning the rate of production in the face...suggests that ribosomes can pass directly from termination...the protein production rate and ribosome density on...

2014-01-01T23:59:59.000Z

472

Estimation of the mass outflow rates from viscous accretion discs  

Science Journals Connector (OSTI)

......entropy accretion rate for the jet is...problems in accretion physics is to determine...But the flow may pass through various...post-shock flow has to pass through another...the accretion rate of pre-shock...the mass outflow rate is given by where...either the flow passes through only one......

Rajiv Kumar; Indranil Chattopadhyay

2013-01-01T23:59:59.000Z

473

Penetration rate prediction for percussive drilling via dry friction model  

E-Print Network [OSTI]

Penetration rate prediction for percussive drilling via dry friction model Anton M. Krivtsov a. Similarly, an increased weight on bit in downhole drilling does not improve the penetration rates when hard- tration rate is presented. The inherent nonlinearity of the discontinuous impact process is modelled

Krivtsov, Anton M.

474

EIS-0093: Bonneville Power Administration's 1982 Rate Proposal  

Broader source: Energy.gov [DOE]

The U.S. Department of Energy's Bonneville Power Administration prepared this statement to evaluate the potential environmental impacts associated with an increase in wholesale power rates for calendar year 1982, including the effects of rate hikes in that year, the cumulative effects of rate hikes from 1979-1985, as well as alternative revenue scenarios.

475

EIS-0102: Bonneville Power Administration's 1983 Wholesale Power Rate  

Broader source: Energy.gov [DOE]

The U.S. Department of Energy's Bonneville Power Administration prepared this EIS to evaluate the potential environmental impacts associated with an increase in wholesale power rates that would become effective on November 1, 1983, including the effects of rate hikes in that year and the cumulative effects of previous rate hikes.

476

HEART RATE VARIABILITY AS DETERMINISM WITH JUMP STOCHASTIC PARAMETERS  

E-Print Network [OSTI]

HEART RATE VARIABILITY AS DETERMINISM WITH JUMP STOCHASTIC PARAMETERS JIONGXUAN ZHENG, JOE SKUFCA, AND ERIK BOLLT§ Abstract. We use measured heart rate information (RR intervals) to develop a one with persistence which causes the heart rate and rhythm system to wander about a bifurcation point. We propose

Bollt, Erik

477

Heart Rate Dynamics Before Spontaneous Onset of Ventricular  

E-Print Network [OSTI]

Heart Rate Dynamics Before Spontaneous Onset of Ventricular Fibrillation in Patients With Healed V. Huikuri, MD The traditional methods of analyzing heart rate (HR) variability have failed myocardial infarction has been shown to be in- creased in patients with reduced heart rate (HR) vari- ability

478

An Evolutionary Reduction Principle for Mutation Rates at Multiple Loci  

E-Print Network [OSTI]

An Evolutionary Reduction Principle for Mutation Rates at Multiple Loci Lee Altenberg altenber of the reduction principle is found: reduction results at individual loci combine topologically to produce to the reduction principle, and under fine tuning of mutation rates would be expected to have higher mutation rates

Altenberg, Lee

479

Optimization of well rates under gas coning conditions  

E-Print Network [OSTI]

production rates under gas caning conditions. This new method applies to an oil reservoir overlain by a large gas cap containing multiple wells. The cases consider have a limit on the maximum field production rate for both oil and gas. It was found... that the optimal p~ion rates are achieved when Eq. 1 is satisfied for any pair of wells i and j: ) I = constant i = 1, . . . , n dqo This condition minimizes the f ield gas production rate when the maximum field production rate for oil is met, and maximizes...

Urbanczyk, Christopher Henry

2012-06-07T23:59:59.000Z

480

Use of Coupled Rate Equations To Describe Nucleation-and-Branching Rate-Limited Solid-State Processes  

Science Journals Connector (OSTI)

Use of Coupled Rate Equations To Describe Nucleation-and-Branching Rate-Limited Solid-State Processes ... Coincident with nuclei growth may be the process of nuclei multiplication or “branching”. ... We consider that nucleation and branching may be considered as two interrelated yet distinct steps (often rate determining) in a series of steps required to achieve a conversion. ...

Peter J. Skrdla

2004-07-20T23:59:59.000Z

Note: This page contains sample records for the topic "kv rating mva" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Compensated count-rate circuit for radiation survey meter  

DOE Patents [OSTI]

A count-rate compensating circuit is provided which may be used in a portable Geiger-Mueller (G-M) survey meter to ideally compensate for counting loss errors in the G-M tube detector. In a G-M survey meter, wherein the pulse rate from the G-M tube is converted into a pulse rate current applied to a current meter calibrated to indicate dose rate, the compensated circuit generates and controls a reference voltage in response to the rate of pulses from the detector. This reference voltage is gated to the current-generating circuit at a rate identical to the rate of pulses coming from the detector so that the current flowing through the meter is varied in accordance with both the frequency and amplitude of the reference voltage pulses applied thereto so that the count rate is compensated ideally to indicate a true count rate within 1% up to a 50% duty cycle for the detector. A positive feedback circuit is used to control the reference voltage so that the meter output tracks true count rate indicative of the radiation dose rate.

Todd, Richard A. (Powell, TN)

1981-01-01T23:59:59.000Z

482

Compensated count-rate circuit for radiation survey meter  

DOE Patents [OSTI]

A count-rate compensating circuit is provided which may be used in a portable Geiger-Mueller (G-M) survey meter to ideally compensate for couting loss errors in the G-M tube detector. In a G-M survey meter, wherein the pulse rate from the G-M tube is converted into a pulse rate current applied to a current meter calibrated to indicate dose rate, the compensation circuit generates and controls a reference voltage in response to the rate of pulses from the detector. This reference voltage is gated to the current-generating circuit at a rate identical to the rate of pulses coming from the detector so that the current flowing through the meter is varied in accordance with both the frequency and amplitude of the reference voltage pulses applied thereto so that the count rate is compensated ideally to indicate a true count rate within 1% up to a 50% duty cycle for the detector. A positive feedback circuit is used to control the reference voltage so that the meter output tracks true count rate indicative of the radiation dose rate.

Todd, R.A.

1980-05-12T23:59:59.000Z

483

Replacement-1 Wholesale Power Rate Schedule | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Replacement-1 Wholesale Power Rate Schedule Replacement-1 Wholesale Power Rate Schedule Replacement-1 Wholesale Power Rate Schedule Area: Replacement Energy System: Georgia-Alabama-South Carolina This rate schedule shall be available to public bodies and cooperatives (any one of whom is hereinafter called the Customer) in Georgia, Alabama, Mississippi, Florida, South Carolina, or North Carolina to whom power is provided pursuant to contracts between the Government and the Customer. This rate schedule shall be applicable to the sale at wholesale energy purchased to meet contract minimum energy and sold under appropriate contracts between the Government and the Customer. Document Available for Download Replacement-1 Rate Schedule More Documents & Publications Replacement-3 Wholesale Power Rate Schedule

484

CC-1-I Wholesale Power Rate Schedule | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

CC-1-I Wholesale Power Rate Schedule CC-1-I Wholesale Power Rate Schedule CC-1-I Wholesale Power Rate Schedule Area: Carolina Power & Light Company, Western Division System: CU This rate schedule shall be available to public bodies and cooperatives served through the facilities of Carolina Power & Light Company, Western Division (hereinafter called the Customers). This rate schedule shall be applicable to electric capacity and energy available from the Dale Hollow, Center Hill, Wolf Creek, Cheatham, Old Hickory, Barkley, J. Percy Priest, and Cordell Hull Projects (all of such projects being hereinafter called collectively the "Cumberland Projects") and sold in wholesale quantities. Document Available for Download CC-1-I Rate Schedule More Documents & Publications CM-1-H Wholesale Power Rate Schedule

485

CC-1-I Wholesale Power Rate Schedule | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

CC-1-I Wholesale Power Rate Schedule CC-1-I Wholesale Power Rate Schedule CC-1-I Wholesale Power Rate Schedule Area: Carolina Power & Light Company, Western Division System: CU This rate schedule shall be available to public bodies and cooperatives served through the facilities of Carolina Power & Light Company, Western Division (hereinafter called the Customers). This rate schedule shall be applicable to electric capacity and energy available from the Dale Hollow, Center Hill, Wolf Creek, Cheatham, Old Hickory, Barkley, J. Percy Priest, and Cordell Hull Projects (all of such projects being hereinafter called collectively the "Cumberland Projects") and sold in wholesale quantities. Document Available for Download CC-1-I Rate Schedule More Documents & Publications CM-1-H Wholesale Power Rate Schedule

486

Alternative Fuels Data Center: Alternative Fuel Tax Exemption and Rate  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Alternative Fuel Tax Alternative Fuel Tax Exemption and Rate Reduction to someone by E-mail Share Alternative Fuels Data Center: Alternative Fuel Tax Exemption and Rate Reduction on Facebook Tweet about Alternative Fuels Data Center: Alternative Fuel Tax Exemption and Rate Reduction on Twitter Bookmark Alternative Fuels Data Center: Alternative Fuel Tax Exemption and Rate Reduction on Google Bookmark Alternative Fuels Data Center: Alternative Fuel Tax Exemption and Rate Reduction on Delicious Rank Alternative Fuels Data Center: Alternative Fuel Tax Exemption and Rate Reduction on Digg Find More places to share Alternative Fuels Data Center: Alternative Fuel Tax Exemption and Rate Reduction on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type

487

Property:OpenEI/UtilityRate/DemandRateStructure/Tier3Max | Open Energy  

Open Energy Info (EERE)

Max" Max" Showing 13 pages using this property. 4 4b524791-bef2-49b1-850b-458730755203 + 5 + 4b524791-bef2-49b1-850b-458730755203 + 5 + 4b524791-bef2-49b1-850b-458730755203 + 6 + 4b524791-bef2-49b1-850b-458730755203 + 7 + 4b524791-bef2-49b1-850b-458730755203 + 3 +, 4 +, 5 +, ... 4b524791-bef2-49b1-850b-458730755203 + 9 + 4b524791-bef2-49b1-850b-458730755203 + 3 + 4b524791-bef2-49b1-850b-458730755203 + 30 + 4b524791-bef2-49b1-850b-458730755203 + 4 + 4b524791-bef2-49b1-850b-458730755203 + 36 + E E40880ac-c27b-4cbf-a011-b0d7d6e10fe9 + 200 + E40880ac-c27b-4cbf-a011-b0d7d6e10fe9 + 200 + E40880ac-c27b-4cbf-a011-b0d7d6e10fe9 + 200 + Retrieved from "http://en.openei.org/w/index.php?title=Property:OpenEI/UtilityRate/DemandRateStructure/Tier3Max&oldid=539747

488

Physical acoustic information for magnitude estimation of rate of speech  

Science Journals Connector (OSTI)

Several studies have demonstrated that the phonetic identity of a segment can be altered by the rate of a precursive sequence. While this rate normalization effect has been shown for both consonants and vowels [J. L. Miller Phonetica 38 159–180(1981)] it has never been clear what the physical acoustic basis of the rate information is. In these experiments subjects' magnitude estimations of rate for a short passage are used to assess the physical acoustic parameters used by the listener to perceive rate of speech. From earlier experiments [F. Grosjean and N. Lass Lang. Speech20(3) 198–208(1977)] it appears likely that the source of information for rate is not based upon any higher information including words or word boundaries. In the first experiment subjects give rate estimations for a passage spoken at five rates by a female English speaker that has been low?pass filtered at 300 Hz. Estimates for these filtered stimuli in which energy for F1 and higher formants is deleted leaving only pitch and amplitude information are indistinguishable from those for intact passages. It appears then that not even phonetic perception is necessary for perception of rate in this paradigm. Data for estimates of rate for passages with only pitch or only amplitude information will also be presented. [Work supported by NINCDS.

Keith R. Kluender

1984-01-01T23:59:59.000Z

489

PSNC Energy (Gas) - Green Building Rate Discount | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

PSNC Energy (Gas) - Green Building Rate Discount PSNC Energy (Gas) - Green Building Rate Discount PSNC Energy (Gas) - Green Building Rate Discount < Back Eligibility Commercial Residential Savings Category Heating & Cooling Home Weatherization Construction Commercial Weatherization Commercial Heating & Cooling Design & Remodeling Solar Lighting Windows, Doors, & Skylights Heating Buying & Making Electricity Water Heating Wind Program Info State North Carolina Program Type Utility Rate Discount Rebate Amount $0.05 discount/therm Provider PSNC Energy This discounted rate is available to commercial customers whose building meets the U.S. Green Building Council's Leadership in Energy and Environmental Design (LEED) certification or equivalent. To qualify, the customer must be on the Rate 125. Qualifying customers pay $.05 per therm

490

Duke-1-E Wholesale Power Rate Schedule | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

1-E Wholesale Power Rate Schedule 1-E Wholesale Power Rate Schedule Duke-1-E Wholesale Power Rate Schedule Area: Duke On-System System: Georgia-Alabama-South Carolina This rate schedule shall be available to public bodies and cooperatives (any one of whom is hereinafter called the Customer) in North Carolina and South Carolina to whom power may be transmitted and scheduled pursuant to contracts between the Government and Duke Energy Company (hereinafter called the Company) and the Customer. This rate schedule shall be applicable to the sale at wholesale of power and accompanying energy generated at the Allatoona, Buford, J. Strom Thurmond, Walter F. George, Hartwell, Millers Ferry, West Point, Robert F. Henry, Carters and Richard B. Russell Projects and sold under appropriate contracts between the Government and the Customer. This rate schedule does

491

VA-4-B Wholesale Power Rate Schedule | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

4-B Wholesale Power Rate Schedule 4-B Wholesale Power Rate Schedule VA-4-B Wholesale Power Rate Schedule Area: Virginia Power System: Kerr-Philpott This rate schedule shall be available to public bodies and cooperatives (any one of whom is hereinafter called the Customer) in Virginia and North Carolina served through the transmission facilities of Virginia Electric and Power Company (hereinafter called the Company) and PJM Interconnection LLC (hereinafter called PJM). This rate schedule shall be applicable to the sale at wholesale of power and accompanying energy generated at the John H. Kerr and Philpott Projects (hereinafter called the Projects) and sold under appropriate contracts between the Government and the Customer. Document Available for Download VA-4-B Rate Schedule More Documents & Publications

492

MISS-1-N Wholesale Power Rate Schedule | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

MISS-1-N Wholesale Power Rate Schedule MISS-1-N Wholesale Power Rate Schedule MISS-1-N Wholesale Power Rate Schedule Area: South Mississippi Electric Power Association System: Georgia-Alabama-South Carolina This rate schedule shall be available to the South Mississippi Electric Power Association (hereinafter called the Customer) to whom power may be wheeled pursuant to contracts between the Government and PowerSouth Energy Cooperative (hereinafter called PowerSouth). This rate schedule shall be applicable to the sale at wholesale of power and accompanying energy generated at the Allatoona, Buford, J. Strom Thurmond, Walter F. George, Hartwell, Millers Ferry, West Point, Robert F. Henry, Carters and Richard B. Russell Projects and sold under appropriate contracts between the Government and the Customer. This rate schedule does

493

AP-4-B Wholesale Power Rate Schedule | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

4-B Wholesale Power Rate Schedule 4-B Wholesale Power Rate Schedule AP-4-B Wholesale Power Rate Schedule Area: American Electric Power System: Kerr-Philpott This rate schedule shall be available to public bodies and cooperatives (any one of whom is hereinafter called the Customer) in Virginia served through the facilities of American Electric Power Service Corporation (hereinafter called the Company) and PJM Interconnection LLC (hereinafter called PJM). This rate schedule shall be applicable to the sale at wholesale of power and accompanying energy generated at the John H. Kerr and Philpott Projects (hereinafter called the Projects) and sold under appropriate contracts between the Government and the Customer. Document Available for Download AP-4-B Rate Schedule More Documents & Publications

494

Flag rates for deletion? | OpenEI Community  

Open Energy Info (EERE)

Flag rates for deletion? Flag rates for deletion? Home > Groups > Utility Rate I found some "rates" that don't belong; they are one-time connection fees instead of rates (e.g. with a $2,500 connection fee as a "fixed monthly charge"). Is there some way to flag rates for suggested deletion? Submitted by Ewilson on 22 June, 2012 - 11:27 1 answer Points: 1 Hi Ewilson, Thank you for pointing this out! We are currently working on a way for users to propose deletion: http://en.openei.org/wiki/Help:Deleting_pages. Let me know if you have any questions! Wzeng on 12 July, 2012 - 08:19 Groups Menu You must login in order to post into this group. Recent content There is currently no way to s... ranking of utilities by demand charge? FYI, OpenEI now accommodates t... Very useful information. Thank...

495

Replacement-2-A Wholesale Power Rate Schedule | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

2-A Wholesale Power Rate Schedule 2-A Wholesale Power Rate Schedule Replacement-2-A Wholesale Power Rate Schedule Area: Replacement Energy System: Kerr-Philpott This rate schedule shall be available to public bodies and cooperatives (any one of whom is hereinafter called the Customer) in North Carolina and Virginia to whom power is provided pursuant to contracts between the Government and the customer from the John H. Kerr and Philpott Projects (or Kerr-Philpott System). This rate schedule shall be applicable to the sale of wholesale energy purchased to meet contract minimum energy and sold under appropriate contracts between the Government and the Customer. Document Available for Download Replacement-2-A Rate Schedule More Documents & Publications Southeastern Power Administration 2010 Annual Report

496

Santee-3-E Wholesale Power Rate Schedule | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

3-E Wholesale Power Rate Schedule 3-E Wholesale Power Rate Schedule Santee-3-E Wholesale Power Rate Schedule Area: None System: Georgia-Alabama-South Carolina This rate schedule shall be available to public bodies and cooperatives (any one of whom is hereinafter call the Customer) in South Carolina to whom power may be scheduled pursuant to contracts between the Government and South Carolina Public Service Authority (hereinafter called the Authority). This rate schedule shall be applicable to the sale at wholesale of power and accompanying energy generated at the Allatoona, Buford, J. Strom Thurmond, Walter F. George, Hartwell, Millers Ferry, West Point, Robert F. Henry, Carters and Richard B. Russell Projects and sold under appropriate contracts between the Government and the Customer. This rate schedule does

497

Santee-1-E Wholesale Power Rate Schedule | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

1-E Wholesale Power Rate Schedule 1-E Wholesale Power Rate Schedule Santee-1-E Wholesale Power Rate Schedule Area: Central, Bamberg, and Georgetown System: Georgia-Alabama-South Carolina This rate schedule shall be available to public bodies and cooperatives (any one of whom is hereinafter call the Customer) in South Carolina to whom power may be wheeled and scheduled pursuant to contracts between the Government and South Carolina Public Service Authority (hereinafter called the Authority). This rate schedule shall be applicable to the sale at wholesale of power and accompanying energy generated at the Allatoona, Buford, J. Strom Thurmond, Walter F. George, Hartwell, Millers Ferry, West Point, Robert F. Henry, Carters and Richard B. Russell Projects and sold under appropriate contracts between the Government and the Customer. This rate schedule does

498

Santee-4-E Wholesale Power Rate Schedule | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

4-E Wholesale Power Rate Schedule 4-E Wholesale Power Rate Schedule Santee-4-E Wholesale Power Rate Schedule Area: Santee-Cooper System: Georgia-Alabama-South Carolina This rate schedule shall be available to public bodies and cooperatives (any one of whom is hereinafter call the Customer) in South Carolina served through the transmission facilities of South Carolina Public Service Authority (hereinafter called the Authority). This rate schedule shall be applicable to the sale at wholesale of power and accompanying energy generated at the Allatoona, Buford, J. Strom Thurmond, Walter F. George, Hartwell, Millers Ferry, West Point, Robert F. Henry, Carters and Richard B. Russell Projects and sold under appropriate contracts between the Government and the Customer. This rate schedule does not apply to energy from pumping operations at the Carters and Richard B.

499

Average Interest Rate for Treasury Securities | Data.gov  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Average Interest Rate for Treasury Securities Average Interest Rate for Treasury Securities Consumer Data Apps Challenges Resources About Blogs Let's Talk Feedback Consumer You are here Data.gov » Communities » Consumer » Data Average Interest Rate for Treasury Securities Dataset Summary Description This dataset shows the average interest rates for U.S Treasury securities for the most recent month compared with the same month of the previous year. The data is broken down by the various marketable and non-marketable securities. The summary page for the data provides links for monthly reports from 2001 through the current year. Average Interest Rates are calculated on the total unmatured interest-bearing debt. The average interest rates for total marketable, total non-marketable and total interest-bearing debt do not include the U.S. Treasury Inflation-Protected Securities.

500

Electrochemical Corrosion Rate Sensors for Waste Incineration Applications  

SciTech Connect (OSTI)

Electrochemical corrosion rate sensors work in high temperature waste incineration applications where ash is deposited. The ash serves as the electrolyte for electrochemical measurements, such as liner polarization resistance, electrochemical noise, and harmonic distortion analyses. Results to date have shown that these types of sensors respond qualitatively to changes in temperature, gas composition, alloy composition, and type of ash. Several years of research have shown that high temperature corrosion rate probes need to be better understood before corrosion rate can be used as a process variable by power plant operators. More recent research has shown that electrochemical corrosion probes typically measure lower corrosion rates than those measured by standard mass loss techniques. While still useful for monitoring changes in corrosion rates, absolute probe corrosion rates will need a calibration factor to be useful. Ideas for research that may help resolve these issues are presented.

Covino, B.S., Jr.; Bullard, S.J.; Matthes, S.A.; Holcomb, G.R.; Ziomek-Moroz, M.; Eden, D.A. (Honeywell Intercorr)

2007-03-01T23:59:59.000Z