Powered by Deep Web Technologies
Note: This page contains sample records for the topic "kafb kirtland air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Sandia National Laboratories: Sandia/KAFB Wind Farm  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

MOU Signing SandiaKAFB Wind Farm On May 18, 2011, in Energy, News, Renewable Energy, Wind Energy ALBUQUERQUE, N.M. - Sandia National Laboratories and Kirtland Air Force Base...

2

Geologic investigation :an update of subsurface geology on Kirtland Air Force Base, New Mexico.  

SciTech Connect (OSTI)

The objective of this investigation was to generate a revised geologic model of Kirtland Air Force Base (KAFB) incorporating the geological and geophysical data produced since the Site-Wide Hydrogeologic Characterization Project (SWHC) of 1994 and 1995. Although this report has certain stand-alone characteristics, it is intended to complement the previous work and to serve as a status report as of late 2002. In the eastern portion of KAFB (Lurance Canyon and the Hubbell bench), of primary interest is the elevation to which bedrock is buried under a thin cap of alluvium. Elevation maps of the bedrock top reveal the paleodrainage that allows for the interpretation of the area's erosional history. The western portion of KAFB consists of the eastern part of the Albuquerque basin where bedrock is deeply buried under Santa Fe Group alluvium. In this area, the configuration of the down-to-the-west, basin-bounding Sandia and West Sandia faults is of primary interest. New geological and geophysical data and the reinterpretation of old data help to redefine the location and magnitude of these elements. Additional interests in this area are the internal stratigraphy and structure of the Santa Fe Group. Recent data collected from new monitoring wells in the area have led to a geologic characterization of the perched Tijeras Arroyo Groundwater system and have refined the known limits of the Ancestral Rio Grande fluvial sediments within the Santa Fe Group. Both the reinterpretation of the existing data and a review of the regional geology have shown that a segment of the boundary between the eastern and western portions of KAFB is a complicated early Tertiary (Laramide) wrench-fault system, the Tijeras/Explosive Ordnance Disposal Area/Hubbell Spring system. A portion of this fault zone is occupied by a coeval ''pull-apart'' basin filled with early Tertiary conglomerates, whose exposures form the ''Travertine Hills''.

Van Hart, Dirk (GRAM, Inc.)

2003-06-01T23:59:59.000Z

3

NNSA to save $7 million on electricity at Sandia, Kirtland Air...  

National Nuclear Security Administration (NNSA)

to save 7 million on electricity at Sandia, Kirtland Air Force Base over two years | National Nuclear Security Administration Facebook Twitter Youtube Flickr RSS People Mission...

4

Distribution System Audits, Leak Detection, and Repair: Kirtland Air Force Base Leak Detection and Repair Program  

Broader source: Energy.gov (indexed) [DOE]

Best Management Practice Best Management Practice Case Study #3 Distribution System Audits, Leak Detection, and Repair Kirtland Air Force Base - Leak Detection and Repair Program Overview Kirtland Air Force Base (AFB) performed an award winning leak detection and repair program in 2006. The results of the project are saving Kirtland AFB 179 million gallons each year, which is over 16% of the total water use at the base. Kirtland AFB is located on 52,000 acres, southeast and adjacent to Albuquerque, New Mexico. The area is a high altitude desert, only receiving about 8 inches of rain each year. Kirtland AFB draws water from an under- ground aquifer via seven production wells through- out the base. The base also has access to water from the City of Albuquerque. The underground water

5

Distribution System Audits, Leak Detection, and Repair: Kirtland Air Force Base Leak Detection and Repair Program  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Best Management Practice Best Management Practice Case Study #3 Distribution System Audits, Leak Detection, and Repair Kirtland Air Force Base - Leak Detection and Repair Program Overview Kirtland Air Force Base (AFB) performed an award winning leak detection and repair program in 2006. The results of the project are saving Kirtland AFB 179 million gallons each year, which is over 16% of the total water use at the base. Kirtland AFB is located on 52,000 acres, southeast and adjacent to Albuquerque, New Mexico. The area is a high altitude desert, only receiving about 8 inches of rain each year. Kirtland AFB draws water from an under- ground aquifer via seven production wells through- out the base. The base also has access to water from the City of Albuquerque. The underground water

6

Geothermal potential on Kirtland Air Force Base lands, Bernalillo County, New Mexico  

SciTech Connect (OSTI)

Extensive sampling and geochemical analysis of groundwater in and near the base disclosed no significant geothermal parameters. However, structural conditions and current hydrologic regimes strongly suggest that thermal waters would be masked by near surface, low temperature meteoric water originating as rain and snowfall in the nearby mountains. Controlled source audio-magnetotelluric (CSAMT) electromagnetic techniques, refraction seismic experiments, and gravity traverses were utilized on the base. These, together with published geohysical information that presents evidence for a shallow magma body beneath the Albuquerque Basin; favorable terrestrial heat flow, water chemistry, and shallow temperature gradient holes on the nearby mesa west of the Rio Grande; interpretation of regional gravity data; and geological data from nearby deep wells tend to confirm structural, stratigraphic, and hydrologic conditions favorable for developing an extensive intermediate to high-temperature hydrothermal regime on portions of Kirtland AFB lands where intensive land use occurs. Two possible exploration and development scenarios are presented. One involves drilling a well to a depth of 3000 to 5000 ft (914 to 1524 m) to test the possibility of encountering higher than normal water temperatures on the basinward side of the faults underlying the travertine deposits. The other is to conduct limited reflection seismograph surveys in defined areas on the base to determine the depth to basement (granite) and thickness of the overyling, unconfined, water filled, relatively unconsolidated sand and gravel aquifer.

Grant, P.R. Jr.

1981-10-01T23:59:59.000Z

7

Kirtland, Ohio: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Kirtland, Ohio: Energy Resources Kirtland, Ohio: Energy Resources Jump to: navigation, search Equivalent URI DBpedia Coordinates 41.6289365°, -81.3614985° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":41.6289365,"lon":-81.3614985,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

8

Voluntary Protection Program Onsite Review, FMT Kirtland- December 2012  

Broader source: Energy.gov [DOE]

This report summarizes the results of the HSS DOE-VPP Teams evaluation of FMT Kirtland during the period of December 5-9, 2011, and provides the Chief Health, Safety and Security Officer with the necessary information to make the final decision regarding the companys continued participation in DOE-VPP as a Star site.

9

Kirtland Hills, Ohio: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Kirtland Hills, Ohio: Energy Resources Kirtland Hills, Ohio: Energy Resources Jump to: navigation, search Equivalent URI DBpedia Coordinates 41.6239365°, -81.3070506° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":41.6239365,"lon":-81.3070506,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

10

CX-004216: Categorical Exclusion Determination | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

16: Categorical Exclusion Determination 16: Categorical Exclusion Determination CX-004216: Categorical Exclusion Determination Kirtland Air Force Base Cougar Research Support CX(s) Applied: B3.3 Date: 06/08/2010 Location(s): New Mexico Office(s): Sandia Site Office Sandia National Laboratories/New Mexico (SNL/NM) proposes to assist Kirtland Air Force Base (KAFB) contract biologists in the use of track surveys and systematic camera arrays to assess the prevalence of cougars (Puma concolor) on KAFB and United States Department of Energy (DOE) land. In addition, four cougars would be fitted with global positioning system (GPS) satellite collars to assess their use of base property, to calculate the probability of detecting resident cougars using remote cameras, to measure predation rates on base wildlife, and to create a map of cougar

11

ITL  

Office of Legacy Management (LM)

Inhalation Toxicology Laboratory, New Mexico, Site. Inhalation Toxicology Laboratory, New Mexico, Site. This site is managed by the U.S. Department of Energy Office of Legacy Management. Site Description and History The Inhalation Toxicology Laboratory (ITL) site is located on the southern edge of Kirtland Air Force Base (KAFB) in Albuquerque, New Mexico. The site occupies 240,000 square feet of building space on 144 acres of

12

EA-1906-FEA-2012  

Broader source: Energy.gov (indexed) [DOE]

Final Final ENVIRONMENTAL ASSESSMENT FOR OPERATIONS, UPGRADES, AND CONSOLIDATION AT THE WESTERN COMMAND SITE, NEW MEXICO June 2012 National Nuclear Security Administration Office of Secure Transportation P.O. Box 5400 Albuquerque, New Mexico 87185-5400 This page intentionally left blank. Cover Sheet ENVIRONMENTAL ASSESSMENT FOR OPERATIONS, UPGRADES, AND CONSOLIDATION AT THE WESTERN COMMAND SITE, NEW MEXICO Proposed Action: The Department of Energy (DOE) National Nuclear Security Administration (NNSA) proposes to construct and operate a consolidated Western Command facility at Kirtland Air Force Base (KAFB). Report Designation: Final Environmental Assessment Responsible Agency: NNSA Affected Location: Kirtland AFB, New Mexico

13

Microsoft Word - G009-002-AOWC Draft EA-3-28-12  

Broader source: Energy.gov (indexed) [DOE]

Draft Draft ENVIRONMENTAL ASSESSMENT FOR OPERATIONS, UPGRADES, AND CONSOLIDATION AT THE WESTERN COMMAND SITE, NEW MEXICO April 2012 National Nuclear Security Administration Office of Secure Transportation P.O. Box 5400 Albuquerque, New Mexico 87185-5400 This page intentionally left blank. Cover Sheet ENVIRONMENTAL ASSESSMENT FOR OPERATIONS, UPGRADES, AND CONSOLIDATION AT THE WESTERN COMMAND SITE, NEW MEXICO Proposed Action: The Department of Energy (DOE) National Nuclear Security Administration (NNSA) proposes to construct and operate a consolidated Western Command facility at Kirtland Air Force Base (KAFB). Report Designation: Draft Environmental Assessment Responsible Agency: NNSA Affected Location: Kirtland AFB, New Mexico

14

Sandia National Laboratories site-wide hydrogeologic characterization project calendar year 1992 annual report  

SciTech Connect (OSTI)

The Sandia National Laboratories, New Mexico (SNL/NM) Site-Wide Hydrogeologic Characterization (SWHC) project has been implemented as part of the SNL/NM Environmental Restoration (ER) Program to develop the regional hydrogeologic framework and baseline for the approximately 100 mi of Kirtland Air Force Base (KAFB) and adjacent withdrawn public lands upon which SNL/NM has performed research and development activities. Additionally, the SWHC project will investigate and characterize generic hydrogeologic issues associated with the 172 ER sites owned by SNL/NM across its facilities on KAFB. As called for in the Hazardous and Solid Waste Amendments (HSWA) to the Resource Conservation and Recovery Act (RCRA) Part B permit agreement between the U.S. Environmental Protection Agency (EPA) as the permitter and the U.S. Department of Energy (DOE) and SNL/NM as the permittees, an annual report is to be prepared by the SWHC project team. This document serves two primary purposes: (1) to identify and describe the conceptual framework for the hydrogeologic system underlying SNL/NM and (2) to describe characterization activities undertaken in the preceding year that add to our understanding (reduce our uncertainties) regarding the conceptual and quantitative hydrogeologic framework. This SWHC project annual report focuses primarily on purpose 1, providing a summary description of the current {open_quotes}state of knowledge{close_quotes} of the Sandia National Laboratories/Kirtland Air Force Base (SNL/KAFB) hydrogeologic setting.

Crowson, D.; Gibson, J.D.; Haase, C.S.; Holt, R.; Hyndman, D.; Krumhansl, J.; Lauffer, F.; McCord, J.P.; McCord, J.T.; Neel, D. [and others

1993-10-01T23:59:59.000Z

15

Natural Tracers and Multi-Scale Assessment of Caprock Sealing Behavior: A Case Study of the Kirtland Formation, San Juan Basin  

SciTech Connect (OSTI)

The assessment of caprocks for geologic CO{sub 2} storage is a multi-scale endeavor. Investigation of a regional caprock - the Kirtland Formation, San Juan Basin, USA - at the pore-network scale indicates high capillary sealing capacity and low permeabilities. Core and wellscale data, however, indicate a potential seal bypass system as evidenced by multiple mineralized fractures and methane gas saturations within the caprock. Our interpretation of {sup 4}He concentrations, measured at the top and bottom of the caprock, suggests low fluid fluxes through the caprock: (1) Of the total {sup 4}He produced in situ (i.e., at the locations of sampling) by uranium and thorium decay since deposition of the Kirtland Formation, a large portion still resides in the pore fluids. (2) Simple advection-only and advection-diffusion models, using the measured {sup 4}He concentrations, indicate low permeability ({approx}10-20 m{sup 2} or lower) for the thickness of the Kirtland Formation. These findings, however, do not guarantee the lack of a large-scale bypass system. The measured data, located near the boundary conditions of the models (i.e., the overlying and underlying aquifers), limit our testing of conceptual models and the sensitivity of model parameterization. Thus, we suggest approaches for future studies to better assess the presence or lack of a seal bypass system at this particular site and for other sites in general.

Jason Heath; Brian McPherson; Thomas Dewers

2011-03-15T23:59:59.000Z

16

RECORD OF CATEGORICAL EXCLUSION (CX) DETERMINATION I National Nuclear Security Administration/Kansas City Site Office  

Broader source: Energy.gov (indexed) [DOE]

National Nuclear Security Administration/Kansas City Site Office National Nuclear Security Administration/Kansas City Site Office A. Description of Proposed Action: (lor 2 sentences: include title, general activities, location, timeframc) Kirtland Operations - Project 1769 - Relocate NC-135 Site Operations: transfer existing operations from the NC-135 site on Kirtland Air force Base (KAFB) to leased and other Federal property. No buildings designed for occupancy are being relocated. Transfer will consist of tenant improvements to the new leased properties and transfer through the relocation of existing equipment and office personnel. November 2012 thru April 2014. B. Number and Title of the Categorical Exclusion Being Applied: (See text in 10 CFR 1021, Subpart D.) B 1.24 - Property Transfer B 1.31 - Installation or relocation of machinery and equipment

17

Vol. 62 No. 104 Friday, May 30, 1997 p 29332 (Notice)  

Broader source: Energy.gov (indexed) [DOE]

ENERGY ENERGY Site-Wide Environmental Impact Statement; Sandia National Laboratories/New Mexico AGENCY: Department of Energy. ACTION: Notice of intent. SUMMARY: The Department of Energy (DOE) announces its intent to prepare a Site-Wide Environmental Impact Statement (SWEIS) for its Sandia National Laboratories/New Mexico (SNL/NM), a DOE research and development laboratory located on Kirtland Air Force Base (KAFB) in Albuquerque, New Mexico. The SWEIS will address operations and activities that DOE foresees at SNL/NM for approximately the next 10 years. The U.S. Air Force will participate as a cooperating agency. The purpose of this Notice is to invite public participation in the process and to encourage public dialogue on alternatives that should be considered.

18

CX-002261: Categorical Exclusion Determination | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

1: Categorical Exclusion Determination 1: Categorical Exclusion Determination CX-002261: Categorical Exclusion Determination Electromagnetic Measurements and Testing CX(s) Applied: B3.11 Date: 03/08/2010 Location(s): New Mexico Office(s): NNSA-Headquarters, Sandia Site Office Sandia National Laboratories/New Mexico (SNL/NM) proposes a medium-term program to measure electromagnetic emanations from various sources in and about SNL/NM, Kirtland Air Force Base (KAFB), and other off-site locations in the continental United States. These measurements would utilize electric and magnetic field sensors and data-recording equipment. Electromagnetic sources of interest to be measured would include: 1. Facilities that use Marx generators 2) High-explosive (HE) above- and below-ground detonations (i.e., during normal mining operations).

19

South Fence Road -- Phase 1 field operations summary  

SciTech Connect (OSTI)

The South Fence Road (SFR) project is part of the Sandia National Laboratories, New Mexico (SNL/NM) Site-Wide Hydrogeologic Characterization (SWHC) task. The SWHC task has as its objective the reduction of uncertainty about the rate and direction of groundwater flow in the SNL/NM/Kirtland Air Force Base (KAFB) area. The SFR project area is located along the southern boundary of SNL/KAFB. This project area was selected to provide site-specific information related to geology and groundwater hydrology within the Hubbell Spring/Tijeras/Sandia fault complex. Specific objectives included determining the depth to the Santa Fe Group/bedrock contact, the depth to the water table, and the hydrogeologic complexities related to faulting. This report is a basic data report from the first phase of field operations associated with the drilling, logging, completion, and development of South Fence Road Wells SFR-1D and SFR-1S, SFR-2, SFR-3D and SFR-3S, and SFR-4. These test/monitoring wells were installed as part of Sandia National Laboratories, New Mexico, Environmental Restoration Project.

McCord, J.P. [INTERA, Inc., Albuquerque, NM (United States); Neel, D. [GRAM, Inc., Albuquerque, NM (United States)

1996-03-01T23:59:59.000Z

20

Air Conditioning  

Science Journals Connector (OSTI)

Air Conditioning ... CHEMISTS and engineers use air conditioning as a valuable tool in more than two hundred industries. ... Air conditioning is a tool with many facets. ...

MARGARET INGELS

1938-02-10T23:59:59.000Z

Note: This page contains sample records for the topic "kafb kirtland air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Hydrodynamic Modeling of Air Blast Propagation from the Humble Redwood Chemical High Explosive Detonations Using GEODYN  

SciTech Connect (OSTI)

Two-dimensional axisymmetric hydrodynamic models were developed using GEODYN to simulate the propagation of air blasts resulting from a series of high explosive detonations conducted at Kirtland Air Force Base in August and September of 2007. Dubbed Humble Redwood I (HR-1), these near-surface chemical high explosive detonations consisted of seven shots of varying height or depth of burst. Each shot was simulated numerically using GEODYN. An adaptive mesh refinement scheme based on air pressure gradients was employed such that the mesh refinement tracked the advancing shock front where sharp discontinuities existed in the state variables, but allowed the mesh to sufficiently relax behind the shock front for runtime efficiency. Comparisons of overpressure, sound speed, and positive phase impulse from the GEODYN simulations were made to the recorded data taken from each HR-1 shot. Where the detonations occurred above ground or were shallowly buried (no deeper than 1 m), the GEODYN model was able to simulate the sound speeds, peak overpressures, and positive phase impulses to within approximately 1%, 23%, and 6%, respectively, of the actual recorded data, supporting the use of numerical simulation of the air blast as a forensic tool in determining the yield of an otherwise unknown explosion.

Chipman, V D

2011-09-20T23:59:59.000Z

22

Compressed Air  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

BPA Utility Reimbursement Programs for Compressed Air Projects Customer Proposal Template Measurement & Verification Plan for Compressed Air CA 2006-15 A template for utilities to...

23

Air Quality  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

What We Monitor & Why » What We Monitor & Why » Air Quality Air Quality To preserve our existing wilderness-area air quality, LANL implements a conscientious program of air monitoring. April 12, 2012 Real-time data monitoring for particulate matter An air monitoring field team member tests one of LANL's tapered element oscillating microbalance samplers, which collects real-time particulate matter data. Contact Environmental Communication & Public Involvement P.O. Box 1663 MS M996 Los Alamos, NM 87545 (505) 667-0216 Email LANL monitors air quality 24 hours a day, 365 days a year. Why we monitor air LANL monitors many different pathways in order to assess their impact on workers, the public, animals, and plants. We monitor the air around the Laboratory to ensure our operations are not affecting the air of nearby

24

Air Pollution  

Science Journals Connector (OSTI)

Both natural processes and human activities contribute to air pollution, with the combustion of fossil fuels being the largest anthropogenic source of air pollutants. Adverse health effects (above all respiratory and cardiovascular complications), damage to crops, natural vegetation and materials, reduced visibility and changed radiation balance of the atmosphere are the major consequences of high concentrations of air pollutants. Technical fixes can sharply reduce emissions from large stationary sources and lower the rates of automotive emissions, but the rising number of vehicles and longer time spent on the road will call for more radical solutions to traffic-generated photochemical smog now present in all major urban areas.

V. Smil

2001-01-01T23:59:59.000Z

25

Bos > AIR  

E-Print Network [OSTI]

The advent of air travel has produced a building typology completely new to the 20th century. The outdated planning of regions for airports render most existing airports as isolated, autonomous instances in the urban ...

Lee, Kevin Young

2014-01-01T23:59:59.000Z

26

Air Resources: Prevention and Control of Air Contamination and Air  

Broader source: Energy.gov (indexed) [DOE]

Air Resources: Prevention and Control of Air Contamination and Air Air Resources: Prevention and Control of Air Contamination and Air Pollution, Air Quality Classifications and Standards, and Air Quality Area Classifications (New York) Air Resources: Prevention and Control of Air Contamination and Air Pollution, Air Quality Classifications and Standards, and Air Quality Area Classifications (New York) < Back Eligibility Agricultural Fuel Distributor Industrial Institutional Investor-Owned Utility Local Government Multi-Family Residential Municipal/Public Utility Nonprofit Rural Electric Cooperative Schools State/Provincial Govt Transportation Tribal Government Utility Program Info State New York Program Type Environmental Regulations Provider NY Department of Environmental Conservation These regulations establish emissions limits and permitting and operational

27

Air Leakage of Furnaces and Air Handlers  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Air Leakage of Furnaces and Air Handlers Air Leakage of Furnaces and Air Handlers Title Air Leakage of Furnaces and Air Handlers Publication Type Journal Article LBNL Report Number LBNL-5553E Year of Publication 2010 Authors Walker, Iain S., Mile Lubliner, Darryl J. Dickerhoff, and William W. Delp Journal 2010 ACEEE Summer Study on Energy Efficiency in Buildings The Climate for efficiency is now Date Published 08/2010 Abstract In recent years, great strides have been made in reducing air leakage in residential and to a lesser extent small commercial forced air duct systems. Several authorities have introduced low leakage limits for thermal distribution systems; for example, the State of California Energy Code for Buildings gives credit for systems that leak less than 6% of the total air flow at 25 Pa.

28

Metal-Air Batteries  

SciTech Connect (OSTI)

Metal-air batteries have much higher specific energies than most currently available primary and rechargeable batteries. Recent advances in electrode materials and electrolytes, as well as new designs on metal-air batteries, have attracted intensive effort in recent years, especially in the development of lithium-air batteries. The general principle in metal-air batteries will be reviewed in this chapter. The materials, preparation methods, and performances of metal-air batteries will be discussed. Two main metal-air batteries, Zn-air and Li-air batteries will be discussed in detail. Other type of metal-air batteries will also be described.

Zhang, Jiguang; Bruce, Peter G.; Zhang, Gregory

2011-08-01T23:59:59.000Z

29

Air Pollution Control  

Science Journals Connector (OSTI)

Petroleum and chemical processes are responsible for many emissions both into the air. Most relevant emissions into the air are nitrous oxides (NOx), sulfur oxides ... compounds (VOC).The major cause of all air pollution

Alireza Bahadori

2014-01-01T23:59:59.000Z

30

Hickam Air Force Base  

Broader source: Energy.gov [DOE]

Hickam Air Force Base spans 2,850 acres in Honolulu, Hawaii. The military base is home to the 15th Airlift Wing, the Hawaii Air National Guard, and the Pacific Air Forces headquarters.

31

OLYMPIC AIR QUALITY QUESTIONABLE  

Science Journals Connector (OSTI)

OLYMPIC AIR QUALITY QUESTIONABLE ... Athletes GOING FOR GOLD worry about Beijings air ... Atmospheric chemists say the air quality during the Beijing Games literally rests on which direction the winds blow. ...

RACHEL PETKEWICH

2008-07-28T23:59:59.000Z

32

Air Quality and Pollution  

Science Journals Connector (OSTI)

Air quality refers to the physical, chemical, and biological characteristics of air, both in outside space and in enclosed ... other non?industrial working places, and residencies. Air pollution is the abnormal ...

Zoran Marmut

2008-01-01T23:59:59.000Z

33

Primary zone air proportioner  

DOE Patents [OSTI]

An air proportioner is provided for a liquid hydrocarbon fueled gas turbine of the type which is convertible to oil gas fuel and to coal gas fuel. The turbine includes a shell for enclosing the turbine, an air duct for venting air in said shell to a gasifier, and a fuel injector for injecting gasified fuel into the turbine. The air proportioner comprises a second air duct for venting air from the air duct for mixing with fuel from the gasifier. The air can be directly injected into the gas combustion basket along with the fuel from the injector or premixed with fuel from the gasifier prior to injection by the fuel injector.

Cleary, Edward N. G. (San Diego, CA)

1982-10-12T23:59:59.000Z

34

Air Pollution Spring 2010  

E-Print Network [OSTI]

and control. 6. Examine regional and global air pollution issues. Prerequisite: CHEM 113 and (MATH 261 or MATHATS 555 Air Pollution Spring 2010 T Th 11:00 ­ 12:15, NESB 101 Instructor: Prof. Sonia Kreidenweis an understanding of types and sources of air pollution. 2. Examine concentrations of air pollutants

35

Healthy Air Act (Maryland)  

Broader source: Energy.gov [DOE]

The Maryland Healthy Air Act was developed with the purpose of bringing Maryland into attainment with the National Ambient Air Quality Standards (NAAQS) for ozone and fine particulate matter by the...

36

Air and Water Pollution  

Science Journals Connector (OSTI)

Air Pollution.... Many pollutants enter our bodies through the air we breathe at 13,000l/day ... to quantitatively understand the basic environmental physics of pollution. This chapter covers the foll...

David Hafemeister

2014-01-01T23:59:59.000Z

37

Aesculap, Inc. Air Products  

E-Print Network [OSTI]

Aesculap, Inc. Air Products Air Products Foundation Alaric Compliance Services, LLC Alvin H. Butz & Herger, Inc. Sodexo Campus Services Sodexo Inc. and Affiliates Stupp Bros., Inc. Sugarbush Products, Inc

Napier, Terrence

38

Minimize Compressed Air Leaks  

Broader source: Energy.gov [DOE]

This tip sheet outlines a strategy for compressed air leak detection and provides a formula for cost savings calculations.

39

Air Products effective way  

E-Print Network [OSTI]

PE O A e s a b O T A O ENNST Overview Air Products effective way standard me Departm Shipping has recently y of shipping eans. Air Pro ontainer that es of this pro onduct mark eep accelera eep the cost tilize widely a earch and m m visited Air er needs wer model was cr m approache ms

Demirel, Melik C.

40

Determining the Right Air Quality for Your Compressed Air System  

Broader source: Energy.gov [DOE]

This tip sheet outlines the main factors for determining the right air quality for compressed air systems.

Note: This page contains sample records for the topic "kafb kirtland air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Thin Air Breathing  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Thin Air Breathing Thin Air Breathing Name: Amy Location: N/A Country: N/A Date: N/A Question: Why is it hard to breathe in thin air? What health dangers do mountain climbers face at high altitudes? Replies: Among the obvious dangers of losing ones footing, the oxygen available in the air is considerable less at higher altitudes. If I recall correctly, 21% of the atmosphere at standard temperature and pressure at sea level is composed of oxygen. This is less at higher altitudes. One can lose consciousness and even die in an oxygen deficient environment with changes from oxygen content to lower than 19.5%. This can unfortunate effect can occur within minutes. Dr. Myron The air is not really thin at high altitudes. The problem is that air pressure is lower. As altitude increases, air pressure decreases. In order for your lungs to fill with air, the air pressure in your lungs has to be less than the pressure of the air outside your lungs. Air moves from areas of higher pressure to lower pressure. As your diaphragm (the muscle that separates your chest cavity from your abdominal cavity) moves downward, the size of your chest cavity increases. This decreases the pressure in your chest and air flows in. When the diaphragm is up, it puts pressure on the chest cavity and the pressure in the lungs is greater than outside the lungs. Air flows out. This is an example of Boyle's Law. The movement of the diaphragm is controlled by the brainstem. Anyway-the reason that it is harder for some people to breathe at higher altitudes is that the air pressure differences aren't as great between the inside of the lungs and outside.

42

Graphene nanoribbons in criss-crossed electric and magnetic fields  

Science Journals Connector (OSTI)

...Electronic and photonic properties of graphene layers and carbon nanoribbons' compiled...Gumbs, Danhong Huang and Oleksiy Roslyak Graphene nanoribbons in criss-crossed electric...Kirtland Air Force Base, , NM-87117, USA Graphene nanoribbons (GNRs) in mutually perpendicular...

2010-01-01T23:59:59.000Z

43

Environmental Quality: Air (Louisiana)  

Broader source: Energy.gov [DOE]

The Department of Environmental Quality regulates air quality in Louisiana. The Department has an established a fee system for funding the monitoring, investigation and other activities required...

44

Air-Quality Regulations  

Science Journals Connector (OSTI)

n...Federal, state and/or local regulations constructed for the purpose of protecting air quality, e.g., low volatile organic compounds...

Jan W. Gooch

2011-01-01T23:59:59.000Z

45

Air-quality regulations  

Science Journals Connector (OSTI)

n....Federal, state and/or local regulations constructed for the purpose of protecting air quality, e.g., low volatile organic compounds...

2007-01-01T23:59:59.000Z

46

International MODIS and AIRS processing package: AIRS products and applications  

E-Print Network [OSTI]

International MODIS and AIRS processing package: AIRS products and applications Elisabeth Weisz presented and discussed in this paper demonstrate that the IMAPP AIRS retrieval product is rigorously parameters from the operational AIRS L2 product and data from other instruments. Keywords: AIRS, IMAPP

Li, Jun

47

Clean air act and National Ambient Air Quality Standards (NAAQS)  

E-Print Network [OSTI]

Clean air act and National Ambient Air Quality Standards (NAAQS) Ozone: Sources/Environmental Effects Particulates (PM): Sources/Environmental Effects #12;National Ambient Air Quality Standards (NAAQS) The Clean Air Act requires EPA to set National Ambient Air Quality Standards for pollutants considered

Weber, Rodney

48

Compressed Air System Optimization  

E-Print Network [OSTI]

Several years ago I went to a gas station and noticed that my car's tires were low on air. I saw the gas station had an air compressor, but it cost a quarter to use the compressor. I paid my quarter and used the compressor. I realized...

Aegerter, R.

49

Recirculating electric air filter  

DOE Patents [OSTI]

An electric air filter cartridge has a cylindrical inner high voltage electrode, a layer of filter material, and an outer ground electrode formed of a plurality of segments moveably connected together. The outer electrode can be easily opened to remove or insert filter material. Air flows through the two electrodes and the filter material and is exhausted from the center of the inner electrode.

Bergman, W.

1985-01-09T23:59:59.000Z

50

Portable oven air circulator  

DOE Patents [OSTI]

A portable air circulating apparatus for use in cooking ovens which is used to create air currents in the oven which transfer heat to cooking foodstuffs to promote more rapid and more uniform cooking or baking, the apparatus including a motor, fan blade and housing of metallic materials selected from a class of heat resistant materials.

Jorgensen, Jorgen A. (Bloomington, MN); Nygren, Donald W. (Minneapolis, MN)

1983-01-01T23:59:59.000Z

51

Meeting the Air Leakage  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Meeting the Air Leakage Meeting the Air Leakage Requirements of the 2012 IECC The U.S. Department of Energy (DOE) recognizes the enormous potential that exists for improving the energy efficiency, safety and comfort of homes. The newest edition of the International Energy Conservation Code ® (IECC) (2012) sets the bar higher for energy efficiency, and new air sealing requirements are one of the key new provisions. This guide is a resource for understanding the new air leakage requirements in the 2012 IECC and suggestions on how these new measures can be met. It also provides information from Building America's Air Sealing Guide, Best Practices and case studies on homes that are currently meeting the provisions. The 2012 IECC and a few International Residential Code (IRC) requirements are referenced throughout the guide.

52

Air Handling Unit Supply Air Temperature Optimization During Economizer Cycles  

E-Print Network [OSTI]

Air Handling Unit Supply Air Temperature Optimization during Economizer Cycles Gang Wang, Zhan Wang, Ke Xu and Mingsheng Liu University of Nebraska Lincoln Omaha, Nebraska, USA ABSTRACT Most air handling units (AHUs) in commercial...

Xu, K.; Liu, M.; Wang, G.; Wang, Z.

2007-01-01T23:59:59.000Z

53

Air ejector augmented compressed air energy storage system  

DOE Patents [OSTI]

Energy is stored in slack demand periods by charging a plurality of underground reservoirs with air to the same peak storage pressure, during peak demand periods throttling the air from one storage reservoir into a gas turbine system at a constant inlet pressure until the air pressure in the reservoir falls to said constant inlet pressure, thereupon permitting air in a second reservoir to flow into said gas turbine system while drawing air from the first reservoir through a variable geometry air ejector and adjusting said variable geometry air ejector, said air flow being essentially at the constant inlet pressure of the gas turbine system.

Ahrens, Frederick W. (Naperville, IL); Kartsounes, George T. (Naperville, IL)

1980-01-01T23:59:59.000Z

54

Abatement of Air Pollution: Prohibition of Air Pollution (Connecticut)  

Broader source: Energy.gov [DOE]

All air pollution not otherwise covered by these regulations is prohibited. Stationary sources which cause air pollution must be operated in accordance with all applicable emissions standards and...

55

Air Pollution and Health Effects  

Science Journals Connector (OSTI)

The quality of the air we breathe is still a major concern to human health. Notwithstanding the air pollution mitigation efforts that have been pursued since ... be attributed to the effects of urban outdoor air

Ana Isabel Miranda; Joana Valente

2014-01-01T23:59:59.000Z

56

Air Quality (Nova Scotia, Canada)  

Broader source: Energy.gov [DOE]

Nova Scotia Environment is responsible for monitoring the air quality in the province, as well as administering fines and permits relating to air quality. The Air Quality Regulations state...

57

Global air quality and climate  

E-Print Network [OSTI]

CRITICAL REVIEW Global air quality and climatewz Arlene M.determine regional air quality and can alter climate.to-continental scale air quality. Reducing the O 3 precursor

2012-01-01T23:59:59.000Z

58

Air heating system  

DOE Patents [OSTI]

A self-starting, fuel-fired, air heating system including a vapor generator, a turbine, and a condenser connected in a closed circuit such that the vapor output from the vapor generator is conducted to the turbine and then to the condenser where it is condensed for return to the vapor generator. The turbine drives an air blower which passes air over the condenser for cooling the condenser. Also, a condensate pump is driven by the turbine. The disclosure is particularly concerned with the provision of heat exchanger and circuitry for cooling the condensed fluid output from the pump prior to its return to the vapor generator.

Primeau, John J. (19800 Seminole Rd., Euclid, OH 44117)

1983-03-01T23:59:59.000Z

59

Maintaining System Air Quality | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Maintaining System Air Quality Maintaining System Air Quality This tip sheet discusses how to maintain air quality in compressed air systems through proper use of equipment....

60

Compressed Air Systems | Department of Energy  

Energy Savers [EERE]

Maintenance Strategies for Compressed Air Systems Remove Condensate with Minimal Air Loss Stabilizing System Pressure Compressed Air Training Compressed Air Systems Tools...

Note: This page contains sample records for the topic "kafb kirtland air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Compressed Air Storage Strategies | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Storage Strategies Compressed Air Storage Strategies This tip sheet briefly discusses compressed air storage strategies. COMPRESSED AIR TIP SHEET 9 Compressed Air Storage...

62

Air Quality Rules (North Carolina)  

Broader source: Energy.gov [DOE]

This is a comprehensive air quality rule for North Carolina that includes ambient air quality standards, emission control standards, monitoring and reporting requirements, and permitting procedures...

63

Ambient Air Quality Standards (Iowa)  

Broader source: Energy.gov [DOE]

These regulations set statewide ambient air quality standards for various contaminants. The state code follows the regulations set forth in the National Primary and Secondary Ambient Air Quality...

64

Padding with Compressed Air  

E-Print Network [OSTI]

We commonly find plants using padding to transport liquids or light solids short distances from tankers into storage tanks. Padding can wreck havoc in compressed air systems with limited storage, undersized cleanup equipment (dryers and filters...

Beals, C.

2004-01-01T23:59:59.000Z

65

Traffic air quality index  

Science Journals Connector (OSTI)

Abstract Vehicle emissions are responsible for a considerable share of urban air pollution concentrations. The traffic air quality index (TAQI) is proposed as a useful tool for evaluating air quality near roadways. The TAQI associates air quality with the equivalent emission from traffic sources and with street structure (roadway structure) as anthropogenic factors. The paper presents a method of determining the TAQI and defines the degrees of harmfulness of emitted pollution. It proposes a classification specifying a potential threat to human health based on the TAQI value and shows an example of calculating the TAQI value for real urban streets. It also considers the role that car traffic plays in creating a local UHI.

Zbigniew Bagie?ski

2015-01-01T23:59:59.000Z

66

Ventilation Air Preconditioning Systems  

E-Print Network [OSTI]

Ventilation Air Preconditioning Systems Mukesh Khattar Michael J. Brandemuehl Manager, Space Conditioning and Refrigeration Associate Professor Customer Systems Group Joint Center for Energy Management Electric Power Research Institute Campus... costs, the small, modular nature of the system allows great flexibility for fitting into retrofit geometries and saves space in new construction. Moreover, a single chiller can serve multiple air-handling units-in stark contrast to packaged...

Khattar, M.; Brandemuehl, M. J.

1996-01-01T23:59:59.000Z

67

Air Cooling | Open Energy Information  

Open Energy Info (EERE)

Cooling Cooling Jump to: navigation, search Dictionary.png Air Cooling: Air cooling is commonly defined as rejecting heat from an object by flowing air over the surface of the object, through means of convection. Air cooling requires that the air must be cooler than the object or surface from which it is expected to remove heat. This is due to the second law of thermodynamics, which states that heat will only move spontaneously from a hot reservoir (the heat sink) to a cold reservoir (the air). Other definitions:Wikipedia Reegle Air Cooling Air Cooling Diagram of Air Cooled Condenser designed by GEA Heat Exchangers Ltd. (http://www.gea-btt.com.cn/opencms/opencms/bttc/en/Products/Air_Cooled_Condenser.html) Air cooling is limited on ambient temperatures and typically require a

68

AIR SEALING Seal air leaks and save energy!  

E-Print Network [OSTI]

AIR SEALING Seal air leaks and save energy! W H A T I S A I R L E A K A G E ? Ventilation is fresh at stopping air leakage. It is critical to seal all holes and seams between these sheet goods with durable air that enters a house in a controlled manner to exhaust excess moisture and reduce odors

Oak Ridge National Laboratory

69

inAir: Sharing Indoor Air Quality Measurements and Visualizations  

E-Print Network [OSTI]

evidence has indicated that indoor air pollution within homes and other buildings can be worse than the outdoor air pollution in even the largest and most industrialized cities. For example, the California Air Resources Board estimates that indoor air pollutant levels are 25-62% greater than outside levels [4

Mankoff, Jennifer

70

Air Quality: Air Pollutants, SLAC Emissions Sources, and Regulatory Reference  

E-Print Network [OSTI]

permit regulations are designed to track, record, and control air pollutants belonging to severalAir Quality: Air Pollutants, SLAC Emissions Sources, and Regulatory Reference Department: Chemical on chemical classifications. This reference outlines major categories of air pollutants found at SLAC

Wechsler, Risa H.

71

PERFORMANCE EVALUATION OF AN AIR-TO-AIR HEAT PUMP COUPLED WITH TEMPERATE AIR-SOURCES INTEGRATED INTO A DWELLING  

E-Print Network [OSTI]

PERFORMANCE EVALUATION OF AN AIR-TO-AIR HEAT PUMP COUPLED WITH TEMPERATE AIR-SOURCES INTEGRATED.peuportier@mines-paristech.fr, Tel.: +33 1 40 51 91 51 ABSTRACT An inverter-driven air-to-air heat pump model has been developped capacity air-to-air heat pump coupled with temperate air sources (crawlspace, attic, sunspace, heat

Paris-Sud XI, Université de

72

EMISSIONS TO AIR OPERATIONAL PROCEDURE  

E-Print Network [OSTI]

EMISSIONS TO AIR OPERATIONAL PROCEDURE Swansea University Estates Services Singleton Park Swansea to Air Department: Estates and Facilities Site: All Author: Ambreen Jahangir Approved by: Mark Durdin PURPOSE: To minimise emissions and discharges to air from boilers, fume cupboards, air conditioning

Harman, Neal.A.

73

Air Quality | Open Energy Information  

Open Energy Info (EERE)

Retrieved from "http:en.openei.orgwindex.php?titleAirQuality&oldid612070" Category: NEPA Resources...

74

Compressed air energy storage system  

DOE Patents [OSTI]

An internal combustion reciprocating engine is operable as a compressor during slack demand periods utilizing excess power from a power grid to charge air into an air storage reservoir and as an expander during peak demand periods to feed power into the power grid utilizing air obtained from the air storage reservoir together with combustible fuel. Preferably the internal combustion reciprocating engine is operated at high pressure and a low pressure turbine and compressor are also employed for air compression and power generation.

Ahrens, Frederick W. (Naperville, IL); Kartsounes, George T. (Naperville, IL)

1981-01-01T23:59:59.000Z

75

Air Charter Services  

Broader source: Energy.gov (indexed) [DOE]

42.2 (April 2012) 42.2 (April 2012) 1 Documentation and Approval of Federally Funded International Travel (Fly America Act-Open Skies Agreement) Overview This section provides guidance to DOE Contracting Officers, Contracting Officer Representatives, and Program Officials on documentation and approval of federally funded international travel by Federal contractors and subcontractors in accordance with FAR 52.247-63 PREFERENCE FOR U.S.-FLAG AIR CARRIERS (JUNE 2003), 49 U.S.C. §40118 (Fly America Act) and the Open Skies Agreements as amended. Background Contracts that include FAR clause 52.247-63, PREFERENCE FOR U.S.-FLAG AIR CARRIERS (JUNE 2003) as prescribed in FAR 47.405 require that, if available, the Contractor (and subcontractors), in performing work under the contract, shall use U.S.-flag air carriers for

76

air_water.cdr  

Office of Legacy Management (LM)

12/2011 12/2011 Air Monitoring Groundwater Monitoring Surface Water Monitoring A continuously operating air monitoring network was in place from 1986 through 2000 for the Weldon Spring Site Remedial Action Project (WSSRAP) to measure levels of gamma radiation, radioactive dust particles, radon gas, and asbestos. With remediation of contaminated materials essentially complete and measurements indistinguishable from background, the U.S. Department of Energy (DOE) ceased perimeter and offsite air monitoring as of December 31, 2000. Groundwater has been routinely monitored at the site since 1986. Separate groundwater monitoring programs were established for the Chemical Plant and Quarry sites because of geographic separation and differences in the hydrogeologic features that influence

77

Sticking with air  

SciTech Connect (OSTI)

A decision to replace more than 300 aging damper actuators at Independence Plant in Newark, Arkensas forced Entergy to make a choice between pneumatic and electric actuator designs. The dampers route air flow through separate dedicated compartments to ensure proper firing of pulverised coal. The reasons that pneumatics was chosen are discussed in this article. 4 figs.

Coker, S.N. [Entergy (US). Independence Plant

2005-06-01T23:59:59.000Z

78

The air plasma spraying  

Science Journals Connector (OSTI)

The air plasma spraying is characterized by using of a compressed air as a plasma forming gas. Here is shown the application of benefits of the present technology compared with other spraying process. The creation of the present process was possible due to a reliable plasma torch and certain condition of heating and deposition of powder materials on a work. Plasma torch develops a power up to 50 kW and can work during 14 hours without replacement of a cathode and during 25 hours as for an anode what is acceptable for industrial application. When spraying of coatings a minimum waste of alloying elements is attained with slight increase of oxygen in coating which is comparable with argon plasma spraying in the open. In certain cases the air plasma spraying allows to obtain more perfect coatings and at high performance. The present method finds large application at restoration and strengthening of machine parts, at forming of components etc. The air plasma spraying provides high quality coatings at low cost of components.

Valery S. Klubnikin

1993-01-01T23:59:59.000Z

79

Canned Air in China  

E-Print Network [OSTI]

Broadcast Transcript: Not that long ago, coal smoke made the air here in Beijing so caustic that your nasal passages were seared with each breath. Those were the good old days: Car ownership was limited to government officials and the rest...

Hacker, Randi

2013-10-23T23:59:59.000Z

80

Industrial HVAC Air-to-Air Energy Recovery Retrofit Economics  

E-Print Network [OSTI]

Retrofitting air-to-air energy recovery equipment is relatively simply to design and easy to install. Additionally, HVAC energy recovery is almost risk free when compared to process retrofit. Life cycle cost analysis is the best way to illustrate...

Graham, E. L.

1980-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "kafb kirtland air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Compressed Air 101: Getting Compressed Air to Work  

E-Print Network [OSTI]

"Air compressors are a significant industrial energy user. Based on a survey (conducted by Oregon State University and the Bonneville Power Administration) of energy audit reports from 125 plants, air compressors account for roughly 10% of total...

Burke, J. J.; Bessey, E. G.

82

Vermont Air Pollution Control Regulations, Ambient Air Quality Standards (Vermont)  

Broader source: Energy.gov [DOE]

The ambient air quality standards are based on the national ambient air quality standards. The Vermont standards are classified as primary and secondary standards and judged adequate to protect...

83

Environmental Pollution Air Pollution Dispersion Practical Air Pollution Dispersion  

E-Print Network [OSTI]

Environmental Pollution Air Pollution Dispersion 1 of 5 Practical ­ Air Pollution Dispersion in the lectures how such models can be used to explain observed concentrations of air pollutants in an area and to test `what-if' scenarios for pollution control and reduction. You will use the Gaussian Plume Model

Moncrieff, John B.

84

Air Conditioning | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Conditioning Conditioning Air Conditioning July 1, 2012 - 6:28pm Addthis Air conditioners cost U.S. homeowners more than $11 billion each year, and regular maintenance can keep your air conditioner running efficiently. | Photo courtesy of ©iStockphoto/JaniceRichard Air conditioners cost U.S. homeowners more than $11 billion each year, and regular maintenance can keep your air conditioner running efficiently. | Photo courtesy of ©iStockphoto/JaniceRichard How does it work? An air conditioner uses energy -- usually electricity -- to transfer heat from the interior of your home to the relatively warm outside environment. Two-thirds of all homes in the United States have air conditioners. Air conditioners use about 5% of all the electricity produced in the United States, at an annual cost of more than $11 billion to homeowners. As a

85

Louisiana Air Control Law (Louisiana)  

Broader source: Energy.gov [DOE]

This law states regulations for air quality control and states the powers and duties of the secretary of environmental quality. It provides information about permits and licenses, air quality...

86

Air Pollution Indicator: PM10  

Science Journals Connector (OSTI)

As one of natural elements, clean air is essential to human beings survival. ... , almost all economic and social activities emit air pollutants, especially such sectors as power and ... and international commun...

Hezhong Tian; Yimeng Liu

2014-01-01T23:59:59.000Z

87

Air Liquide- Biogas & Fuel Cells  

Broader source: Energy.gov [DOE]

Presentation about Air Liquide's biogas technologies and integration with fuel cells. Presented by Charlie Anderson, Air Liquide, at the NREL/DOE Biogas and Fuel Cells Workshop held June 11-13, 2012, in Golden, Colorado.

88

Solar Heating and Air Conditioning  

Science Journals Connector (OSTI)

...given of the status of solar fired air conditioning...to an approach to cool storage in solar air conditioning systems...an assessment of cool storage for reducing peak electrical...rolling cylinder thermal energy storage device for compact...

1980-01-01T23:59:59.000Z

89

Compressed Air Audits using AIRMaster  

E-Print Network [OSTI]

Air compressors are a significant industrial energy user and therefore a prime target for industrial energy audits. The project goal was to develop a software tool, AIRMaster, and supporting methodology for performing compressed air system audits...

Wheeler, G. M.; McGill, R. D.; Bessey, E. G.; Vischer, K.

90

Fundamentals of Compressed Air Systems  

Broader source: Energy.gov [DOE]

Find out how a compressed air system works and the benefits of optimal compressed air system performance. This initial class demonstrates how to compute the current cost of your plant's compressed...

91

Roadway tunnel air quality models  

Science Journals Connector (OSTI)

Roadway tunnel air quality models ... Analysis of 13 tunnel studies quantifies the decline since 1961 in benzo[a]pyrene emitted into the air per km of travel by U.S. road vehicles. ...

Tai Y. Chang; Sara J. Rudy

1990-05-01T23:59:59.000Z

92

Compressed Air System Control Strategies  

Broader source: Energy.gov [DOE]

This tip sheet briefly discusses compressed air system control strategies as a means to improving and maintaining system performance.

93

Compressed Air Energy Storage System  

E-Print Network [OSTI]

/expanders are crucial for the economical viability of a Compressed Air Energy Storage (CAES) system such as the

Farzad A. Shirazi; Mohsen Saadat; Bo Yan; Perry Y. Li; Terry W. Simon

94

Analyzing Your Compressed Air System  

Broader source: Energy.gov [DOE]

This tip sheet outlines the process to analyze industrial compressed air systems and ensure proper system configuration.

95

Air Leaks in Unexpected Places  

Broader source: Energy.gov [DOE]

Sealing air leaks will help to decrease heating and cooling costs and make your home more comfortable.

96

AIR QUALITY REPORT SPARKS CONTROVERSY  

Science Journals Connector (OSTI)

AIR QUALITY REPORT SPARKS CONTROVERSY ... The National Commission on Air Quality delivered its eagerly awaited report to Congress today, and reaction from industry and environmental groups is expected to be both swift and sharp. ... Created under the 1977 Clean Air Act, the commission was charged with assessing the effectiveness of the law, and recommending changes where the law falls short of achieving the goal of improving the nation's air quality. ...

1981-03-02T23:59:59.000Z

97

Air-Lift design theory  

Science Journals Connector (OSTI)

1. Employing graphical relationships between height of lift of the emulsion, depth of shaft, and specific air ra...

P. R. Khlopenkov

1970-10-01T23:59:59.000Z

98

The Viscosity of Air  

Science Journals Connector (OSTI)

The viscosity of air has been remeasured with the rotating cylinder apparatus used by Day and Bleakney. All of the constants have been redetermined, and especial attention has been given to the corrections to the simple theory. The value obtained at 22C is ?=1.82430.0045 c.g.s. units. This raises the oil drop value of e to 4.796 e.s.u. It is shown in the appendix that a correction must be applied for the opening between the suspended cylinder and the guard cylinders, and also a correction must be applied for the moment of inertia of the air carried around by the cylinder when determining its moment of inertia. Neglect of these corrections has introduced some additional uncertainty into other work.

W. V. Houston

1937-10-01T23:59:59.000Z

99

FLUIDIC: Metal Air Recharged  

SciTech Connect (OSTI)

Fluidic, with the help of ARPA-E funding, has developed and deployed the world's first proven high cycle life metal air battery. Metal air technology, often used in smaller scale devices like hearing aids, has the lowest cost per electron of any rechargeable battery storage in existence. Deploying these batteries for grid reliability is competitive with pumped hydro installations while having the advantages of a small footprint. Fluidic's battery technology allows utilities and other end users to store intermittent energy generated from solar and wind, as well as maintain reliable electrical delivery during power outages. The batteries are manufactured in the US and currently deployed to customers in emerging markets for cell tower reliability. As they continue to add customers, they've gained experience and real world data that will soon be leveraged for US grid reliability.

Friesen, Cody

2014-03-07T23:59:59.000Z

100

FLUIDIC: Metal Air Recharged  

ScienceCinema (OSTI)

Fluidic, with the help of ARPA-E funding, has developed and deployed the world's first proven high cycle life metal air battery. Metal air technology, often used in smaller scale devices like hearing aids, has the lowest cost per electron of any rechargeable battery storage in existence. Deploying these batteries for grid reliability is competitive with pumped hydro installations while having the advantages of a small footprint. Fluidic's battery technology allows utilities and other end users to store intermittent energy generated from solar and wind, as well as maintain reliable electrical delivery during power outages. The batteries are manufactured in the US and currently deployed to customers in emerging markets for cell tower reliability. As they continue to add customers, they've gained experience and real world data that will soon be leveraged for US grid reliability.

Friesen, Cody

2014-04-02T23:59:59.000Z

Note: This page contains sample records for the topic "kafb kirtland air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Air Pollution & Health in Rapidly Developing Countries  

E-Print Network [OSTI]

For example, Air Pollution and Health Studies in theAssessment of Air Pollution and Health is illustrative inReview: Air Pollution & Health in Rapidly Developing

Bucher, Scott

2005-01-01T23:59:59.000Z

102

California Air Resources Board | Open Energy Information  

Open Energy Info (EERE)

Air Resources Board Jump to: navigation, search Logo: California Air Resources Board Name: California Air Resources Board Place: Sacramento, California Website: http:...

103

113 air quality control station [n  

Science Journals Connector (OSTI)

envir. (Facility for measurement of air pollution; ? air quality network/system );sestacin [f] de medicin de la calidad del aire (? red de ev...

2010-01-01T23:59:59.000Z

104

ORIGINAL ARTICLE Ambient Air Pollution  

E-Print Network [OSTI]

supporting an association between am- bient air pollution and cardiovascular health, much re- mains health effects of ambient air pollution in Atlanta being undertaken by this Emory investi- gative teamORIGINAL ARTICLE Ambient Air Pollution and Cardiovascular Emergency Department Visits Kristi Busico

Mulholland, James A.

105

Air Pollution Control Regulations: No. 22 - Air Toxics (Rhode Island) |  

Broader source: Energy.gov (indexed) [DOE]

Air Pollution Control Regulations: No. 22 - Air Toxics (Rhode Air Pollution Control Regulations: No. 22 - Air Toxics (Rhode Island) Air Pollution Control Regulations: No. 22 - Air Toxics (Rhode Island) < Back Eligibility Commercial Industrial Investor-Owned Utility Municipal/Public Utility Rural Electric Cooperative Utility Program Info State Rhode Island Program Type Siting and Permitting Provider Department of Environmental Management Permits are required to construct, install, or modify any stationary source which has the potential to increase emissions of a listed toxic air contaminant by an amount greater than the minimum quantity for that contaminant. Minimum quantities are specified in Table III of these regulations. Permits will be granted based in part on the impact of the projected emissions of the stationary source on acceptable ambient levels

106

Air Risk Information Support Center  

SciTech Connect (OSTI)

The Air Risk Information Support Center (Air RISC) was initiated in early 1988 by the US Environmental Protection Agency`s (EPA) Office of Health and Environmental Assessment (OHEA) and the Office of Air Quality Planning and Standards (OAQPS) as a technology transfer effort that would focus on providing information to state and local environmental agencies and to EPA Regional Offices in the areas of health, risk, and exposure assessment for toxic air pollutants. Technical information is fostered and disseminated by Air RISCs three primary activities: (1) a {open_quotes}hotline{close_quotes}, (2) quick turn-around technical assistance projects, and (3) general technical guidance projects. 1 ref., 2 figs.

Shoaf, C.R.; Guth, D.J. [Environmental Protection Agency, Washington, DC (United States)

1990-12-31T23:59:59.000Z

107

Urban and Regional Air Quality  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

equipment equipment Urban and Regional Air Quality Research in this area is concerned with regional air quality issues such as: Controlling nitrogen oxides (NOx) and volatile organic compounds, to manage tropospheric ozone pollution. Hazardous air pollutants: using science to base standards on rigorously studied risks. Air quality and climate: how does climate influence air quality at a regional or local level? Current modeling practices often do not capture variations in pollutants such as ozone-they represent a limited sample of the diverse meteorology and human behavior that affect air pollution. Improved modeling of regional air quality will help understand variability, reveal patterns of behavior, and pollutant transport issues. Controlled experiments in lab and field can help validate improved models.

108

Clean Air Act | Department of Energy  

Office of Environmental Management (EM)

Clean Air Act Clean Air Act The primary law governing the Department of Energy (DOE) air pollution control activities is the Clean Air Act (CAA). This law defines the role of the...

109

Electrocatalysts for Nonaqueous LithiumAir Batteries:...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Electrocatalysts for Nonaqueous LithiumAir Batteries: Status, Challenges, and Perspective. Electrocatalysts for Nonaqueous LithiumAir Batteries: Status, Challenges,...

110

Remove Condensate with Minimal Air Loss  

Broader source: Energy.gov [DOE]

This tip sheet outlines several condensate removal methods as part of maintaining compressed air system air quality.

111

Safeguarding indoor air quality  

SciTech Connect (OSTI)

California has created and implemented the first state program devoted exclusively to the investigation of nonindustrial indoor air quality. The program is responsible for promoting and conducting research on the determining factors of healthful indoor environments and is structured to obtain information about emission sources, ventilation effects, indoor concentrations, human activity patterns, exposures, health risks, control measures and public policy options. Data are gathered by a variety of methods, including research conducted by staff members, review of the available scientific literature, participation in technical meetings, contractual agreements with outside agencies, cooperative research projects with other groups and consultation with experts. 23 references, 1 figure, 1 table.

Sexton, K.; Wesolowski, J.J.

1985-01-01T23:59:59.000Z

112

Abatement of Air Pollution: Hazardous Air Pollutants (Connecticut)  

Broader source: Energy.gov [DOE]

These regulations describe maximum allowable stack concentrations and hazard limiting values for the emission of hazardous air pollutants. The regulations also discuss sampling procedures for...

113

Air Liquide - Biogas & Fuel Cells  

Broader source: Energy.gov (indexed) [DOE]

Liquide - Biogas & Fuel Cells Hydrogen Energy Biogas Upgrading Technology 12 June 2012 Charlie.Anderson@airliquide.com 2 Air Liquide, world leader in gases for industry,...

114

Nebraska Air Quality Regulations (Nebraska)  

Broader source: Energy.gov [DOE]

These regulations, promulgated by the Department of Environmental Quality, contain provisions pertaining to ambient air quality standards, pollution source operating permits, emissions reporting,...

115

Global air quality and climate  

E-Print Network [OSTI]

Chemistry and Climate Model Intercomparison Project (ACCMIP;of chemistryclimate models with RCP emissions thus projectto project air quality responses to future climate change

2012-01-01T23:59:59.000Z

116

Air Force Renewable Energy Programs  

Broader source: Energy.gov [DOE]

Presentation covers Air Force Renewable Energy Programs and is given at the Spring 2011 Federal Utility Partnership Working Group (FUPWG) meeting.

117

Reduce Air Infiltration in Furnaces  

Broader source: Energy.gov [DOE]

This tip sheet describes how to save process heating energy and costs by reducing air infiltration in industrial furnaces; tips include repairing leaks and increasing insulation.

118

Reactive Air Aluminization  

SciTech Connect (OSTI)

Ferritic stainless steels and other alloys are of great interest to SOFC developers for applications such as interconnects, cell frames, and balance of plant components. While these alloys offer significant advantages (e.g., low material and manufacturing cost, high thermal conductivity, and high temperature oxidation resistance), there are challenges which can hinder their utilization in SOFC systems; these challenges include Cr volatility and reactivity with glass seals. To overcome these challenges, protective coatings and surface treatments for the alloys are under development. In particular, aluminization of alloy surfaces offers the potential for mitigating both evaporation of Cr from the alloy surface and reaction of alloy constituents with glass seals. Commercial aluminization processes are available to SOFC developers, but they tend to be costly due to their use of exotic raw materials and/or processing conditions. As an alternative, PNNL has developed Reactive Air Aluminization (RAA), which offers a low-cost, simpler alternative to conventional aluminization methods.

Choi, Jung-Pyung; Chou, Y. S.; Stevenson, Jeffry W.

2011-10-28T23:59:59.000Z

119

An air line carries air at 800 kPa and 80C. An Air line ~ O O C insulated tank initially contains 20C air at a  

E-Print Network [OSTI]

An air line carries air at 800 kPa and 80°C. An Air line ~ O O C insulated tank initially contains 20°C air at a pressure of 90kPa. The valve is opened, and air flows into the tank. Determine the final temperature of the air in the tank and the mass of air that enters the tank if the valve is left

Huang, Haimei

120

Inhalation intake of ambient air pollution in California's South Coast Air Basin  

E-Print Network [OSTI]

the impacts on air pollution and health of urban areaas a proxy for air pollution health effects (Bennett etFuel combustion, air pollution exposure, and health: The

Marshall, Julian D.; Granvold, Patrick W.; Hoats, Abigail S.; McKone, Thomas E.; Deakin, Elizabeth; Nazaroff, William W.

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "kafb kirtland air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Switching Surges and Air Insulation  

Science Journals Connector (OSTI)

...research-article Switching Surges and Air Insulation B. Jones Some thirteen years ago...reduction was noticed in the strength of air insulation when subjected to slowly rising positive...collected in high voltage laboratories. Insulation against switching surges is now seen...

1973-01-01T23:59:59.000Z

122

Protective supplied breathing air garment  

DOE Patents [OSTI]

A breathing air garment for isolating a wearer from hostile environments containing toxins or irritants includes a suit and a separate head protective enclosure or hood engaging a suit collar in sealing attachment. The hood and suit collar are cylindrically shaped and dimensioned to enable the wearer to withdraw his hands from the suit sleeves to perform manual tasks within the hood interior. Breathing air is supplied from an external air line with an air delivery hose attached to the hood interior. The hose feeds air into an annular halo-like fiber-filled plenum having spaced discharge orifices attached to the hood top wall. A plurality of air exhaust/check valves located at the suit extremities cooperate with the hood air delivery system to provide a cooling flow of circulating air from the hood throughout the suit interior. A suit entry seal provided on the suit rear torso panel permits access into the suit and is sealed with an adhesive sealing flap.

Childers, Edward L. (Lakewood, CO); von Hortenau, Erik F. (Golden, CO)

1984-07-10T23:59:59.000Z

123

Protective supplied breathing air garment  

DOE Patents [OSTI]

A breathing air garment is disclosed for isolating a wearer from hostile environments containing toxins or irritants includes a suit and a separate head protective enclosure or hood engaging a suit collar in sealing attachment. The hood and suit collar are cylindrically shaped and dimensioned to enable the wearer to withdraw his hands from the suit sleeves to perform manual tasks within the hood interior. Breathing air is supplied from an external air line with an air delivery hose attached to the hood interior. The hose feeds air into an annular halo-like fiber-filled plenum having spaced discharge orifices attached to the hood top wall. A plurality of air exhaust/check valves located at the suit extremities cooperate with the hood air delivery system to provide a cooling flow of circulating air from the hood throughout the suit interior. A suit entry seal provided on the suit rear torso panel permits access into the suit and is sealed with an adhesive sealing flap. 17 figs.

Childers, E.L.; Hortenau, E.F. von.

1984-07-10T23:59:59.000Z

124

High Efficiency Particulate Air Filters  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

High Efficiency Particulate Air (HEPA) Filters High Efficiency Particulate Air (HEPA) Filters Home Standards DOE Workshops Nuclear Air Cleaning Conference Proceedings Qualified Filter List News Items Related Sites HEPA Related Lessons Learned Contact Us HSS Logo High Efficiency Particulate Air Filters The HEPA Filter web site provides a forum for informing and reporting department-wide activities related to filtration and ventilation issues with special reference to the High Efficiency Particulate Air (HEPA) Filters' use, inspection, and testing. This site contains essentials of DOE HEPA filter test program, procedures, requirements and quality assurance aspects applicable to HEPA filters used in DOE facilities. This site contains information about the DOE-accepted Filter Test Facility and its management, operation and quality assuranceprogram.

125

NETL: IEP - Air Quality Research  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Home > Technologies > Coal & Power Systems > Innovations for Existing Plants > Air Quality Research Home > Technologies > Coal & Power Systems > Innovations for Existing Plants > Air Quality Research Innovations for Existing Plants Air Quality Research Ambient Monitoring Emissions Characterization Predictive Modeling & Evaluation Health Effects Regulatory Drivers Air Quality Research Reference Shelf The NETL Air Quality Research program is designed to resolve the scientific uncertainties associated with the atmospheric formation, distribution, and chemical transformation of pollutant emissions from today's coal-fired power plants, and to obtain a realistic assessment of the human health impacts of these emissions. Results of this research will help the DOE Office of Fossil Energy address policy questions regarding coal plant emissions and provide guidance for future emissions control R&D programs at

126

air conditioner | OpenEI  

Open Energy Info (EERE)

air conditioner air conditioner Dataset Summary Description View 2010 energy efficiency data from AeroSys Inc, Coaire, Cold Point, First Operations, LG Electronics, Nordyne, and Quietside manufacturers. Data includes cooling capacity, cooling performance, heating capacity, and heating performance. Spreadsheet was created by combining the tables in pdf files that are included in the zip file. Source Energy Applicance Data - United States Federal Trade Commission, www.ftc.gov Date Released Unknown Date Updated Unknown Keywords air conditioner central air conditioner efficiency efficient energy heat pump Data application/vnd.ms-excel icon 2010_CentralAC_All.xls (xls, 82.4 KiB) application/zip icon 2010CentralAirConditioner.zip (zip, 398.2 KiB) Quality Metrics Level of Review Some Review

127

Air Force Renewable Energy Programs  

Broader source: Energy.gov (indexed) [DOE]

1 1 Ken Gray P.E. HQ AFCESA /CENR Air Force Renewable Energy Programs April, 2011 FUPWG "Make Energy a Consideration in All We Do" I n t e g r i t y - S e r v i c e - E x c e l l e n c e THINK GREEN, BUILD GREEN, Topics  Air Force Energy Use  Air Force Facility Energy Center  Current RE Generation  Project Development System  Programmed RE Generation FY11-13  Goal Achievement 2 I n t e g r i t y - S e r v i c e - E x c e l l e n c e THINK GREEN, BUILD GREEN, Air Force 2010 Energy Use The Air Force spent approximately $8.2 billion for energy in 2010; an increase of 22% from 2009 Energy Cost and Consumption Trends Energy Cost Breakdown Aviation 79% Facilities 17% 3 Aviation 84% Facilities 12% Vehicles & Equipment

128

Air Leakage and Air Transfer Between Garage and Living Space  

SciTech Connect (OSTI)

This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

Rudd, A.

2014-09-01T23:59:59.000Z

129

Analysis of a Dedicated Outdoor Air System and Low Temperature Supply Air Conditioning System  

E-Print Network [OSTI]

This paper presents the principles and the characteristics of a dedicated outdoor air system (DOAS) and low temperature supply air system. DOAS is offered based on the demands of indoor air quality and the low temperature supply air system...

Guang, L.; Li, R.

2006-01-01T23:59:59.000Z

130

Supply Fan Control for Constant Air Volume Air Handling Units  

E-Print Network [OSTI]

Since terminal boxes do not have a modulation damper in constant volume (CV) air handling unit (AHU) systems, zone reheat coils have to be modulated to maintain the space temperature with constant supply airflow. This conventional control sequence...

Cho, Y.; Wang, G.; Liu, M.

2007-01-01T23:59:59.000Z

131

2011 Air Quality Regulations Report | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Air Quality Regulations Report 2011 Air Quality Regulations Report 2011 Air Quality Regulations Report120111.pdf More Documents & Publications 2011:...

132

Central Air Conditioning | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Central Air Conditioning Central Air Conditioning Central Air Conditioning May 30, 2012 - 8:01pm Addthis Central air conditioners circulate cool air through a system of supply and return ducts. | Photo courtesy of ©iStockphoto/DonNichols. Central air conditioners circulate cool air through a system of supply and return ducts. | Photo courtesy of ©iStockphoto/DonNichols. What does this mean for me? Central air conditioning systems are thermostatically controlled and convenient to use. Central air conditioning systems must be installed properly to operate efficiently. Central air conditioning systems can share ductwork with your heating system. Central air conditioners circulate cool air through a system of supply and return ducts. Supply ducts and registers (i.e., openings in the walls,

133

Tips: Sealing Air Leaks | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Sealing Air Leaks Sealing Air Leaks Tips: Sealing Air Leaks May 16, 2013 - 5:03pm Addthis Sources of Air Leaks in Your Home. Areas that leak air into and out of your home cost you a lot of money. The areas listed in the illustration are the most common sources of air leaks. Sources of Air Leaks in Your Home. Areas that leak air into and out of your home cost you a lot of money. The areas listed in the illustration are the most common sources of air leaks. Air leaks can waste a lot of your energy dollars. One of the quickest energy-- and money-saving tasks you can do is caulk, seal, and weather strip all seams, cracks, and openings to the outside. Tips for Sealing Air Leaks Test your home for air tightness. On a windy day, carefully hold a lit incense stick or a smoke pen next to your windows, doors, electrical

134

Tips: Sealing Air Leaks | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Tips: Sealing Air Leaks Tips: Sealing Air Leaks Tips: Sealing Air Leaks May 16, 2013 - 5:03pm Addthis Sources of Air Leaks in Your Home. Areas that leak air into and out of your home cost you a lot of money. The areas listed in the illustration are the most common sources of air leaks. Sources of Air Leaks in Your Home. Areas that leak air into and out of your home cost you a lot of money. The areas listed in the illustration are the most common sources of air leaks. Air leaks can waste a lot of your energy dollars. One of the quickest energy-- and money-saving tasks you can do is caulk, seal, and weather strip all seams, cracks, and openings to the outside. Tips for Sealing Air Leaks Test your home for air tightness. On a windy day, carefully hold a lit incense stick or a smoke pen next to your windows, doors, electrical

135

Room Air Conditioners | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Room Air Conditioners Room Air Conditioners Room Air Conditioners July 1, 2012 - 5:35pm Addthis A window air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/kschulze. A window air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/kschulze. What does this mean for me? Room air conditioners are less expensive and disruptive to install than central air conditioning systems. Room air conditioners can be a cost-effective alternative to central air conditioning systems. How does it work? Room air conditioners work by cooling one part of your home. Room or window air conditioners cool rooms rather than the entire home or business. If they provide cooling only where they're needed, room air conditioners are less expensive to operate than central units, even though

136

Air Pollution and Epigenetics: Recent Findings  

Science Journals Connector (OSTI)

The health effects of ambient air pollution are well-described, but less is known ... , microRNA, and DNA methylation; along with air pollutant keywords: air pollution, benzo[a]pyrene, nitrogen dioxide, ozone...1

Carrie V. Breton; Amy N. Marutani

2014-03-01T23:59:59.000Z

137

DunoAir | Open Energy Information  

Open Energy Info (EERE)

DunoAir Jump to: navigation, search Name: DunoAir Place: Hessen, Germany Zip: 6865 VX Sector: Wind energy Product: Doorwerth-based wind project developer. References: DunoAir1...

138

Inertial impaction air sampling device  

DOE Patents [OSTI]

An inertial impactor to be used in an air sampling device for collection of respirable size particles in ambient air which may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry. 3 figs.

Dewhurst, K.H.

1987-12-10T23:59:59.000Z

139

ENVITEC shows off air technologies  

SciTech Connect (OSTI)

The ENVITEC International Trade Fair for Environmental Protection and Waste Management Technologies, held in June in Duesseldorf, Germany, is the largest air pollution exhibition in the world and may be the largest environmental technology show overall. Visitors saw thousands of environmental solutions from 1,318 companies representing 29 countries and occupying roughly 43,000 square meters of exhibit space. Many innovations were displayed under the category, ``thermal treatment of air pollutants.`` New technologies include the following: regenerative thermal oxidizers; wet systems for removing pollutants; biological scrubbers;electrostatic precipitators; selective adsorption systems; activated-coke adsorbers; optimization of scrubber systems; and air pollution monitors.

McIlvaine, R.W.

1995-08-01T23:59:59.000Z

140

Inertial impaction air sampling device  

DOE Patents [OSTI]

An inertial impactor to be used in an air sampling device for collection of respirable size particles in ambient air which may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry.

Dewhurst, Katharine H. (13150 Wenonah SE. Apt. 727, Albuquerque, NM 87123)

1990-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "kafb kirtland air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Inertial impaction air sampling device  

DOE Patents [OSTI]

An inertial impactor is designed which is to be used in an air sampling device for collection of respirable size particles in ambient air. The device may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry. 3 figs.

Dewhurst, K.H.

1990-05-22T23:59:59.000Z

142

Air pollution kills. So what? Air quality engineering to improve public health  

E-Print Network [OSTI]

9/14/12 1 Air pollution kills. So what? Air quality engineering to improve public health;9/14/12 5 Health benefits from reducing PM2.5 "Each 10 µg m-3 elevation in fine particle air pollution;9/14/12 2 Air Quality Engineering H Air Quality Engineering H #12;9/14/12 3 Really? Air pollution

Levinson, David M.

143

WearAir: Expressive T-shirts for Air Quality Sensing Sunyoung Kim and Eric Paulos  

E-Print Network [OSTI]

are less proactively concerned with air quality. AIR POLLUTANT: VOLATILE ORGANIC COMPOUNDS Different types of air pollutants contribute to air quality in different locations: Ozone, CO, NOx and VOCs are major contributors to outdoor air pollution; and particulate matters, VOCs, carbon monoxide and lead are common air

Mankoff, Jennifer

144

Degradation characteristics of air cathode in zinc air fuel cells  

Science Journals Connector (OSTI)

Abstract The zinc air fuel cell (ZAFC) is a promising candidate for electrical energy storage and electric vehicle propulsion. However, its limited durability has become a major obstacle for its successful commercialization. In this study, 2-cell stacks, 25cm cells and three-electrode half-cells are constructed to experimentally investigate the degradation characteristics of the air cathode. The results of electrochemical tests reveal that the peak power density for the 25cm2 cell with a new air cathode is 454mWcm?2, which is twice as the value of the used air cathode. The electrochemical impedance analysis shows that both the charge transfer resistance and the mass transfer resistance of the used air cathodes have increased, suggesting that the catalyst surface area and gas diffusion coefficient have decreased significantly. Additionally, the microstructure and morphology of the catalytic layer (CL) and gas diffusion layer (GDL) are characterized by scanning electron microscopes (SEM). SEM results confirm that the micropores in CL and GDL of the used air cathode are seriously clogged, and many catalyst particles are lost. Therefore, the performance degradation is mainly due to the clogging of micropores and loss of catalyst particles. Furthermore, hypotheses of degradation mechanism and mitigation strategies for GDL and CL are discussed briefly.

Ze Ma; Pucheng Pei; Keliang Wang; Xizhong Wang; Huachi Xu; Yongfeng Liu; Guanlin peng

2015-01-01T23:59:59.000Z

145

Integrated Technology Air Cleaners (ITAC): Design and Evaluation  

E-Print Network [OSTI]

of particle air filtration technologies." Indoor Air 12(4):2011a). New air cleaning technologies for reduced commercialnumber 2 Integrated technology air cleaner High efficiency

Fisk, William J.

2014-01-01T23:59:59.000Z

146

Are Ventilation Filters Degrading Indoor Air Quality in California Classrooms?  

E-Print Network [OSTI]

airconditioning IAQ:Indoorairquality LBNL:LawrenceDegrading Indoor Air Quality in California Classrooms? HDEGRADING INDOOR AIR QUALITY IN CALIFORNIA CLASSROOMS?

Fisk, Michael G. Apte and William J.

2009-01-01T23:59:59.000Z

147

Sandia National Laboratories | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Sandia National Laboratories Sandia National Laboratories Sandia National Laboratories This aerial view shows part of Sandia's main campus on Kirtland Air Force Base in Albuquerque, N.M. Photo courtesy Sandia National Laboratories. This aerial view shows part of Sandia's main campus on Kirtland Air Force Base in Albuquerque, N.M. Photo courtesy Sandia National Laboratories. Overview The Sandia National Laboratories (SNL) is comprised of 2,820 acres within the boundaries of the 118 square miles Kirtland Air Force Base, and is located 6.5 miles east of downtown Albuquerque, New Mexico. It is managed by the National Nuclear Security Administration (NNSA), a semiautonomous agency within the U.S. Department of Energy (DOE). SNL was established in 1945 for nuclear weapons development, testing, and

148

Radionuclide Air Emissions Report for 2012  

E-Print Network [OSTI]

Air Emissions Annual Reports for DOE Sites, memo tooffices providing guidance for report preparation (March 22,470E-2012 Radionuclide Air Emission Report for Prepared by

Wahl, Linnea

2014-01-01T23:59:59.000Z

149

Covered Product Category: Room Air Conditioners | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Specifications website. Buying Energy-Efficient Room Air Conditioners When buying room air conditioners directly from commercial sources, choose models that are ENERGY...

150

Aire Valley Environmental | Open Energy Information  

Open Energy Info (EERE)

search Name: Aire Valley Environmental Place: United Kingdom Product: Leeds-based waste-to-energy project developer. References: Aire Valley Environmental1 This article...

151

Air Quality Modeling's Brave New World  

Science Journals Connector (OSTI)

Air Quality Modeling's Brave New World ... A new generation of software systems is set to tackle regional and multipollutant air quality issues. ...

Elaine L. Appleton

2011-06-07T23:59:59.000Z

152

Colorado Air Pollution Control Division - Construction Permits...  

Open Energy Info (EERE)

Jump to: navigation, search OpenEI Reference LibraryAdd to library Web Site: Colorado Air Pollution Control Division - Construction Permits Forms and Air Pollutant Emission...

153

Energy performance of underfloor air distribution systems  

E-Print Network [OSTI]

lossofcontrolofthesupplyairtemperaturefromthelossofcontrolofthe supplyairtemperaturefromthe

Bauman, Fred; Webster, Tom; Linden, Paul; Buhl, Fred

2007-01-01T23:59:59.000Z

154

Mountain Air | Open Energy Information  

Open Energy Info (EERE)

Air Air Jump to: navigation, search Name Mountain Air Facility Mountain Air Sector Wind energy Facility Type Commercial Scale Wind Facility Status In Service Owner Terna Energy Developer Terna Energy Energy Purchaser Idaho Power Location Hammett ID Coordinates 42.98719519°, -115.3985024° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":42.98719519,"lon":-115.3985024,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

155

Missouri Air Conservation Law (Missouri)  

Broader source: Energy.gov [DOE]

This law's purpose is to maintain the purity of the air resources of the state to protect the health, general welfare and physical property of the people, maximum employment and the full industrial...

156

Kansas Air Quality Regulations (Kansas)  

Broader source: Energy.gov [DOE]

All new air contaminant emission sources or alterations to emission sources that are required to be reported shall be in compliance with all applicable emission control regulations at the time that...

157

Natural Air-Conditioning Systems  

Science Journals Connector (OSTI)

Recent research in summer air conditioning utilizing natural sources of coolness* are discussed. These systems are classified according to the sources of coolness, the modes of heat transfer and airflow, and t...

Mehdi N. Bahadori

1986-01-01T23:59:59.000Z

158

ARM - Lesson Plans: Air Pressure  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

activity to work. It is important that students work carefully and slowly. A break in the seal between the cup and card allows air into the cup, causing the water to fall. Note: If...

160

Common Air Conditioner Problems | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Common Air Conditioner Problems Common Air Conditioner Problems Common Air Conditioner Problems May 30, 2012 - 6:41pm Addthis A refrigerant leak is one common air conditioning problem. | Photo courtesy of ©iStockphoto/BanksPhotos. A refrigerant leak is one common air conditioning problem. | Photo courtesy of ©iStockphoto/BanksPhotos. What does this mean for me? You can eliminate the most common air conditioner problems before hiring an air conditioning technician. You can do some air conditioner maintenance and repair tasks yourself. One of the most common air conditioning problems is improper operation. If your air conditioner is on, be sure to close your home's windows and outside doors. For room air conditioners, isolate the room or a group of connected rooms as much as possible from the rest of your home.

Note: This page contains sample records for the topic "kafb kirtland air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Common Air Conditioner Problems | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Common Air Conditioner Problems Common Air Conditioner Problems Common Air Conditioner Problems May 30, 2012 - 6:41pm Addthis A refrigerant leak is one common air conditioning problem. | Photo courtesy of ©iStockphoto/BanksPhotos. A refrigerant leak is one common air conditioning problem. | Photo courtesy of ©iStockphoto/BanksPhotos. What does this mean for me? You can eliminate the most common air conditioner problems before hiring an air conditioning technician. You can do some air conditioner maintenance and repair tasks yourself. One of the most common air conditioning problems is improper operation. If your air conditioner is on, be sure to close your home's windows and outside doors. For room air conditioners, isolate the room or a group of connected rooms as much as possible from the rest of your home.

162

Introduction Air Quality and Nitrogen Dioxide  

E-Print Network [OSTI]

- Global update 2005. Primary sources of air pollutants include combustion products from power generationIntroduction Air Quality and Nitrogen Dioxide Air pollution can be defined as "the presence effects to man and/or the environment". (DEFRA) "Clean air is considered to be a basic requirement

163

INDOOR AIR QUALITY QUESTIONNAIRE HUMAN RESOURCES  

E-Print Network [OSTI]

INDOOR AIR QUALITY QUESTIONNAIRE HUMAN RESOURCES FORM Risk and Compliance | One Washington Square THE AIR QUALITY ISSUE AND LOCATION Name: Date: Department: Phone No: Work Location: Suspected Air Quality, humidity, drafts, stagnant air, odors)? Is there a history of flooding or water damage? If so, please list

Eirinaki, Magdalini

164

AIR QUALITY: Control Enters New Phase  

Science Journals Connector (OSTI)

AIR QUALITY: Control Enters New Phase ... Federal enforcement of air pollution is about to enter a new, more technically sophisticated, phase. ... Now air pollution control moves into the criteria and standards period, when numbers eventually will be the basis for enforcement and the country becomes zoned into 32 air quality regions. ...

1968-08-05T23:59:59.000Z

165

Indoor air quality bill opposed by EPA  

Science Journals Connector (OSTI)

Indoor air quality bill opposed by EPA ... Sen. George J. Mitchell (D.-Me.) has introduced a bill to protect the quality of indoor air. ... According to J. Craig Potter, assistant EPA administrator for air and radiation, the "Indoor Air Quality Act of 1987," S. 1629, is a bill whose time has not yet arrived. ...

LOIS EMBER

1987-12-07T23:59:59.000Z

166

Tips: Air Ducts | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Air Ducts Air Ducts Tips: Air Ducts June 24, 2013 - 7:23pm Addthis Air Ducts: Out of Sight, Out of Mind. The unsealed ducts in your attic and crawlspaces lose air, and uninsulated ducts lose heat -- wasting energy and money. Air Ducts: Out of Sight, Out of Mind. The unsealed ducts in your attic and crawlspaces lose air, and uninsulated ducts lose heat -- wasting energy and money. Your air ducts are one of the most important systems in your home, and if the ducts are poorly sealed or insulated they are likely contributing to higher energy bills. Your home's duct system is a branching network of tubes in the walls, floors, and ceilings; it carries the air from your home's furnace and central air conditioner to each room. Ducts are made of sheet metal, fiberglass, or other materials.

167

Air Breathing Direct Methanol Fuel Cell  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Air Breathing Direct Methanol Fuel Cell Air Breathing Direct Methanol Fuel Cell Air Breathing Direct Methanol Fuel Cell An air breathing direct methanol fuel cell is provided with a membrane electrode assembly, a conductive anode assembly that is permeable to air and directly open to atmospheric air, and a conductive cathode assembly that is permeable to methanol and directly contacting a liquid methanol source. Available for thumbnail of Feynman Center (505) 665-9090 Email Air Breathing Direct Methanol Fuel Cell An air breathing direct methanol fuel cell is provided with a membrane electrode assembly, a conductive anode assembly that is permeable to air and directly open to atmospheric air, and a conductive cathode assembly that is permeable to methanol and directly contacting a liquid methanol

168

Chapter 22: Compressed Air Evaluation Protocol  

SciTech Connect (OSTI)

Compressed-air systems are used widely throughout industry for many operations, including pneumatic tools, packaging and automation equipment, conveyors, and other industrial process operations. Compressed-air systems are defined as a group of subsystems composed of air compressors, air treatment equipment, controls, piping, pneumatic tools, pneumatically powered machinery, and process applications using compressed air. A compressed-air system has three primary functional subsystems: supply, distribution, and demand. Air compressors are the primary energy consumers in a compressed-air system and are the primary focus of this protocol. The two compressed-air energy efficiency measures specifically addressed in this protocol are: high-efficiency/variable speed drive (VSD) compressor replacing modulating compressor; compressed-air leak survey and repairs. This protocol provides direction on how to reliably verify savings from these two measures using a consistent approach for each.

Benton, N.

2014-11-01T23:59:59.000Z

169

Chapter 3 - The Science of Air Pollution  

Science Journals Connector (OSTI)

Abstract Air pollution is defined in various ways, with an introduction to numerous air pollutants in this chapter. The evolution of air pollution science, engineering, and technologies is discussed. The distinction between particulate matter and gaseous air pollutants is made. Particles are described physically, especially with regard to the importance of aerodynamic diameter in terms of human health effects. Stationary and mobile sources of air pollution are discussed, as well as the physical and chemical processes involved in chemical transformation and environmental fate. Air pollution engineering's evolution is considered. The chapter discusses in detail the development of air quality standards and the emergence of laws and regulations to address air pollution. The chapter concludes with a timeline of how air pollution has been perceived over history and how air pollution may change in the future.

Daniel Vallero

2014-01-01T23:59:59.000Z

170

Lessons learned in modeling Underfloor Air Distribution system  

E-Print Network [OSTI]

Underfloor Air Distribution (UFAD) Design Guide. Atlanta:for design cooling loads in underfloor air distribution (

Lee, Kwang Ho; Schiavon, Stefano; Webster, Tom; Bauman, Fred; Feng, Jingjuan; Hoyt, Tyler

2011-01-01T23:59:59.000Z

171

Considering Air Density in Wind Power Production  

E-Print Network [OSTI]

In the wind power production calculations the air density is usually considered as constant in time. Using the CIPM-2007 equation for the density of moist air as a function of air temperature, air pressure and relative humidity, we show that it is worth taking the variation of the air density into account, because higher accuracy can be obtained in the calculation of the power production for little effort.

Farkas, Zn

2011-01-01T23:59:59.000Z

172

Considering Air Density in Wind Power Production  

E-Print Network [OSTI]

In the wind power production calculations the air density is usually considered as constant in time. Using the CIPM-2007 equation for the density of moist air as a function of air temperature, air pressure and relative humidity, we show that it is worth taking the variation of the air density into account, because higher accuracy can be obtained in the calculation of the power production for little effort.

Zn Farkas

2011-03-11T23:59:59.000Z

173

High Energy Efficiency Air Conditioning  

SciTech Connect (OSTI)

This project determined the performance of a new high efficiency refrigerant, Ikon B, in a residential air conditioner designed to use R-22. The refrigerant R-22, used in residential and small commercial air conditioners, is being phased out of production in developed countries beginning this year because of concerns regarding its ozone depletion potential. Although a replacement refrigerant, R-410A, is available, it operates at much higher pressure than R-22 and requires new equipment. R-22 air conditioners will continue to be in use for many years to come. Air conditioning is a large part of expensive summer peak power use in many parts of the U.S. Previous testing and computer simulations of Ikon B indicated that it would have 20 - 25% higher coefficient of performance (COP, the amount of cooling obtained per energy used) than R-22 in an air-cooled air conditioner. In this project, a typical new R-22 residential air conditioner was obtained, installed in a large environmental chamber, instrumented, and run both with its original charge of R-22 and then with Ikon B. In the environmental chamber, controlled temperature and humidity could be maintained to obtain repeatable and comparable energy use results. Tests with Ikon B included runs with and without a power controller, and an extended run for several months with subsequent analyses to check compatibility of Ikon B with the air conditioner materials and lubricant. Baseline energy use of the air conditioner with its original R-22 charge was measured at 90 deg F and 100 deg F. After changeover to Ikon B and a larger expansion orifice, energy use was measured at 90 deg F and 100 deg F. Ikon B proved to have about 19% higher COP at 90 deg F and about 26% higher COP at 100 deg F versus R-22. Ikon B had about 20% lower cooling capacity at 90 deg F and about 17% lower cooling capacity at 100 deg F versus R-22 in this system. All results over multiple runs were within 1% relative standard deviation (RSD). All of these values agree well with previous results and computer simulations of Ikon B performance versus R-22. The lower cooling capacity of Ikon B is not a concern unless a particular air conditioner is near its maximum cooling capacity in application. Typically, oversized A/C systems are installed by contractors to cover contingencies. In the extended run with Ikon B, which lasted about 4.5 months at 100 deg F ambient temperature and 68% compressor on time, the air conditioner performed well with no significant loss of energy efficiency. Post-run analysis of the refrigerant, compressor lubricant oil, compressor, compressor outlet tubing, and the filter/dryer showed minor effects but nothing that was considered significant. The project was very successful. All objectives were achieved, and the performance of Ikon B indicates that it can easily be retrofitted into R-22 air conditioners to give 15 - 20% energy savings and a 1 - 3 year payback of retrofit costs depending on location and use. Ikon B has the potential to be a successful commercial product.

Edward McCullough; Patrick Dhooge; Jonathan Nimitz

2003-12-31T23:59:59.000Z

174

U.S. Air Force Fact Sheet Air Force Reserve Officer Training Corps  

E-Print Network [OSTI]

for the Air Force. Personnel and Resources Air Force Reserve Officer Training Corps (ROTC) includes fourU.S. Air Force Fact Sheet Air Force Reserve Officer Training Corps Mission Develop Quality Leaders Reserve Officer Training Corps is the largest and oldest source of commissioned officers for the Air Force

Su, Xiao

175

AIRS Version 6 Release Level 2 Product User Guide AIRS/AMSU/HSB Version 6  

E-Print Network [OSTI]

AIRS Version 6 Release Level 2 Product User Guide Page 1 AIRS/AMSU/HSB Version 6 Level 2 Product Questions to: http://airs.jpl.nasa.gov/AskAirs #12;AIRS Version 6 Release Level 2 Product User Guide Page 2............................................................................................. 7 1.1 EXAMPLE: LEVEL 2 PHYSICAL RETRIEVAL PRODUCT FILE NAMES

Waliser, Duane E.

176

NAQSAT National Air Quality Site Assessment Tool NAQSAT National Air Quality Site Assessment Tool  

E-Print Network [OSTI]

NAQSAT National Air Quality Site Assessment Tool NAQSAT National Air Quality Site Assessment Tool Air Quality Assessment Tool For Livestock Producers & Advisors #12;NAQSAT The National Air Quality Dairymen National Air Quality Site Assessment Tool Benefits for Producers · Voluntarily and securely assess

177

Numerical Analysis of a Cold Air Distribution System  

E-Print Network [OSTI]

Cold air distribution systems may reduce the operating energy consumption of air-conditioned air supply system and improve the outside air volume percentages and indoor air quality. However, indoor temperature patterns and velocity field are easily...

Zhu, L.; Li, R.; Yuan, D.

2006-01-01T23:59:59.000Z

178

An integrated perspective on assessing agricultural air quality  

E-Print Network [OSTI]

An integrated perspective on assessing agricultural air quality Viney P. Aneja* Department. In this paper, we summarise an integrated assessment framework for studying the agricultural air quality issues air quality; air emissions; air pollution; ammonia; animal feeding operations; biogeochemical cycles

Niyogi, Dev

179

AIR POLLUTION: Diesel Fuel Culprits  

Science Journals Connector (OSTI)

AIR POLLUTION: Diesel Fuel Culprits ... Low-molecular-weight components aren't necessarily the true culprits of diesel fuel pollution, although they do contribute to it, according to Hertha Skala, assistant director of research, and her coworkers F. G. Padrta and P. C. Samson at Universal Oil Products. ... At the first national symposium on heterogeneous catalysis for control of air pollution, sponsored by Philadelphia's Franklin Institute, Mrs. Skala identified five different classes of oxygenated hydrocarbons found over the full molecular-weight range of diesel fuel components. ...

1968-12-02T23:59:59.000Z

180

Optimising the Fresh Air Economiser  

E-Print Network [OSTI]

Optimising the Fresh Air Economiser Rob Bishop Technical Director Energy Solutions Ltd. Wellington New Zealand ABSTRACT This paper proposes using measurements of CO2 to infer the amount of Outside Air (OA) ventilation delivered to a... and the number of occupants only, but since 2004 has also included a value based on the floor area of the space. In New Zealand, the ventilation code is based on ASHRAE Standard 62:1989 (with local amendments), and has not been updated to include the area...

Biship, R.

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "kafb kirtland air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Air Sealing Your Home | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Air Sealing Your Home Air Sealing Your Home Air Sealing Your Home November 26, 2013 - 6:22pm Addthis Save on heating and cooling costs by checking for air leaks in common trouble spots in your home. Save on heating and cooling costs by checking for air leaks in common trouble spots in your home. What does this mean for me? Save money and energy by air sealing your house. Caulking and weatherstripping are simple, effective ways of sealing air leaks in your home. Reducing the amount of air that leaks in and out of your home is a cost-effective way to cut heating and cooling costs, improve durability, increase comfort, and create a healthier indoor environment. Caulking and weatherstripping are two simple and effective air-sealing techniques that offer quick returns on investment, often one year or less. Caulk is

182

Maintaining Your Air Conditioner | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Maintaining Your Air Conditioner Maintaining Your Air Conditioner Maintaining Your Air Conditioner June 18, 2013 - 6:20pm Addthis Replacing or cleaning air conditioner filters is a critical maintenance task. | Photo courtesy of ©iStockphoto/firemanYU. Replacing or cleaning air conditioner filters is a critical maintenance task. | Photo courtesy of ©iStockphoto/firemanYU. What does this mean for me? Regular maintenance keeps your air conditioner running as efficiently as possible. Maintaining your air conditioner will save you money by extending the unit's life. An air conditioner's filters, coils, and fins require regular maintenance for the unit to function effectively and efficiently throughout its years of service. Neglecting necessary maintenance ensures a steady decline in air conditioning performance while energy use steadily increases.

183

Maintaining Your Air Conditioner | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Maintaining Your Air Conditioner Maintaining Your Air Conditioner Maintaining Your Air Conditioner June 18, 2013 - 6:20pm Addthis Replacing or cleaning air conditioner filters is a critical maintenance task. | Photo courtesy of ©iStockphoto/firemanYU. Replacing or cleaning air conditioner filters is a critical maintenance task. | Photo courtesy of ©iStockphoto/firemanYU. What does this mean for me? Regular maintenance keeps your air conditioner running as efficiently as possible. Maintaining your air conditioner will save you money by extending the unit's life. An air conditioner's filters, coils, and fins require regular maintenance for the unit to function effectively and efficiently throughout its years of service. Neglecting necessary maintenance ensures a steady decline in air conditioning performance while energy use steadily increases.

184

Exergy efficiency of a counterflow air/air heat exchanger with vapour condensation  

Science Journals Connector (OSTI)

The exergy efficiency of a counterflow hot moist air/...?1 for the temperature and humidity ratio of hot moist air respectively are considered. Constant ambient air conditions of 20C and 0.01 kgkg?1 were assume...

J. Jilek; J. H. Young

1993-01-01T23:59:59.000Z

185

Review: Clearing the Air: The Health and Economic Damages of Air Pollution in China  

E-Print Network [OSTI]

the assessment of air pollution and its health and economiclargest source of health damages of air pollution in China,to air pollution, and the economic evaluations of health

Lee, Joseph

2009-01-01T23:59:59.000Z

186

Air quality, infant mortality, and the Clean Air Act of 1970  

E-Print Network [OSTI]

We examine the effects of total suspended particulates (TSPs) air pollution on infant health using the air quality improvements induced by the 1970 Clean Air Act Amendments (CAAA). This legislation imposed strict regulations ...

Chay, Kenneth Y.

2003-01-01T23:59:59.000Z

187

Urban Air Quality Management: Detecting and Improving Indoor Ambient Air Quality  

Science Journals Connector (OSTI)

Current air pollution management and air quality control are primarily focused on outdoor and ... which act as public spaces, contaminated indoor air could be public health hazards. In Singapore ... spend a subst...

T. L. Tan; Gissella B. Lebron

2011-01-01T23:59:59.000Z

188

Oil and Gas Air Heaters  

E-Print Network [OSTI]

ICEBO2006, Shenzhen, China Heating technologies for energy efficiency Vol.III-1-2 Oil and Gas Air Heaters1 Guangxiao Kou Hanqing Wang Jiemin Zhou Doctoral Ph.D Ph.D Candidate Professor Professor Hunan University of Technology Hunan...

Kou, G.; Wang, H.; Zhou, J.

2006-01-01T23:59:59.000Z

189

AN IMPROVED AIR-ENGINE  

Science Journals Connector (OSTI)

...bottom of the reverser heater; a cooler, composed...opposite, and the cold chamber above the...and over again. In operation, the alternate raising...mass of air in the cold chamber above the...surface of the reverser heater, thereby becoming...contrary, withstand bad weather and parasites, and...

1889-08-16T23:59:59.000Z

190

Air Capture Introduction and Overview  

E-Print Network [OSTI]

first." It is much cheaper to capture CO2 from the flue gas of a coal power plant than from ambient air largely eliminated centralized sources of CO2 emissions, especially at coal and natural gas power plants of a facility that captures CO2 from the flue gas of a coal power plant, keeping all possible assumptions

191

Air pollution control: Indoor hazards  

Science Journals Connector (OSTI)

... the need for further study of the health effects of indoor air pollution, ranging from radon emitted by building materials to the second-hand effects of cigarette smoke, and the ... overlooked in research on the health effects of environmental pollutants. In some cases,such as radon, the report says that there is an "urgent need" to study such health ...

David Dickson

1981-09-10T23:59:59.000Z

192

AIR FORCE SPECIAL WEAPONS CENTER  

Office of Legacy Management (LM)

HEADQUARTERS aII?y HEADQUARTERS aII?y 9 AIR FORCE SPECIAL WEAPONS CENTER 1 AIR FORCE SYSTEMS COMMAND . - KlRTlAND AIR FORCE BASE, NEW MEXICO - k FINAL REPORT O N AIR FORCE PARTICIPATION PROJECT RULISON .1 O c t o b e r 1969 P r e p a r e d by : CONT INENTAL TEST D I V I S ION DIRECTORATE OF NUCLEAR FIELD OPERATIONS This page intentionally left blank INDEX AIR FORCE PARTICIPATION I N PROJECT RULISON FINAL REPORT PARAGRAPH BASIC REPORT SUBJECT R e f e r e n c e s PAGE 2 G e n e r a l 1 3 P l a n n i n g 3 4 Command a n d C o n t r o l 5 O p e r a t i o n s , G r a n d ' J u n c t i o n M u n i c i p a l A i r p o r t . . ' A i r O p e r a t i o n s C e n t e r , He1 i c o p t e r P a d / ' 7.. - . M a t e r i e l : ' 8 M e d i c a l 1 9 R a d - S a f e C r a s h - R e s c u e S e c u r i t y 2 1 C o m m u n i c a t i o n s ~ d m i n i s t r a t ' i o n Summary ATTACHMENTS ATTACHMENT SUBJECI' 1 F r a g O r d e r 69-1 ( ~ r o j ' e c t RULISON) , AFSWC D

193

Air Pollution Control (Oklahoma) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Air Pollution Control (Oklahoma) Air Pollution Control (Oklahoma) Air Pollution Control (Oklahoma) < Back Eligibility Agricultural Fuel Distributor Industrial Investor-Owned Utility Local Government Municipal/Public Utility Rural Electric Cooperative State/Provincial Govt Systems Integrator Tribal Government Utility Savings Category Buying & Making Electricity Program Info State Oklahoma Program Type Environmental Regulations Provider Environmental Quality This chapter enumerates primary and secondary ambient air quality standards and the significant deterioration increments. Significant deterioration refers to an increase in ambient air pollution above a baseline plus a specific increment allowed for one of three classes of areas. It is required for potential sources of air contaminants to register with the

194

E-Print Network 3.0 - air-to-air heat pumps Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

conditions... data on the seasonal performance of air-to-air residential heat pump systems. The purpose of this paper... of operation 10, 197778, the Control House ......

195

BaP Air Quality Modelling Simulation Using CMAQ Air Quality Modelling System  

Science Journals Connector (OSTI)

Air Quality Modelling has become an essential tool to ... in the atmosphere by using last generation of air quality dispersion models with the inclusion of the...

R San Jos; JL Prez; M Callen; JM Lpez; A Mastral

2013-01-01T23:59:59.000Z

196

Compressed Air Energy Savings: SAV-AIR Monitor and Control System and the PNW Compressed Air Challenge  

E-Print Network [OSTI]

This paper presents the results from two compressed air programs supported by the Northwest Energy Efficiency Alliance (Alliance) over the last five years. In 1997 the Alliance funded the Northwest regional version of the Compressed Air Challenge...

Anderson, K. J.; Annen, B.; Scott, S.

197

The investigation of exhaust powered, automotive air cycle air conditioning  

E-Print Network [OSTI]

Pressure Ratio Net Power Test Apparatus Available Turbocompressors Turbine and Compressor Wheels Mounted to Shaft Turbocompressor Mounted. to Exhaust Line Total System Test Rig Full Throttle Performance Curves Subscript 'c' Corrected Results 13 13... an automotive air cycle unit which employed a rotary- vaned compressor. The prototype unit developed. cooling over various engine speeds because of the compressor being a positive displacement type which developed fairly high pressures on the order of 40 psia...

Holley, James Andrew

1978-01-01T23:59:59.000Z

198

Detecting Air Leaks | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Detecting Air Leaks Detecting Air Leaks Detecting Air Leaks September 27, 2012 - 6:39pm Addthis For a thorough and accurate measurement of air leakage in your home, hire a qualified technician to conduct an energy assessment, particularly a blower door test. For a thorough and accurate measurement of air leakage in your home, hire a qualified technician to conduct an energy assessment, particularly a blower door test. You may already know where some air leakage occurs in your home, such as an under-the-door draft, but you'll need to find the less obvious gaps to properly air seal your home. For a thorough and accurate measurement of air leakage in your home, hire a qualified technician to conduct an energy assessment, particularly a blower door test. A blower door test, which depressurizes a home, can

199

Improving Regional Air Quality with Wind Power  

Wind Powering America (EERE)

Improving Regional Air Quality with Improving Regional Air Quality with Wind Power National Renewable Energy Laboratory Improving Regional Air Quality with Wind Power National Renewable Energy Laboratory * Clean Air Act (CAA) framework * Air quality challenges * CAA policies as market drivers * Met. Wash. Council of Governments (MWCOG) case study * Environmental Protection Agency (EPA) guidance on State Implementation Plan (SIP) credit for EERE * Model SIP documentation for wind purchases * Related marketing innovations Overview Overview * CAA requires regional air quality plans (SIPs) * "Window of opportunity" - Revised SIPs required by 2006/2007 to meet new 8-hour ozone and PM standards - August 2004 EPA guidance and NREL model SIP documentation for wind purchases Clean Air Act Framework Clean Air Act Framework

200

Air-Conditioning Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Air-Conditioning Basics Air-Conditioning Basics Air-Conditioning Basics August 16, 2013 - 1:59pm Addthis Air conditioning is one of the most common ways to cool homes and buildings. How Air Conditioners Work Air conditioners employ the same operating principles and basic components as refrigerators. Refrigerators use energy (usually electricity) to transfer heat from the cool interior of the refrigerator to the relatively warm surroundings; likewise, an air conditioner uses energy to transfer heat from the interior space to the relatively warm outside environment. An air conditioner uses a cold indoor coil called the evaporator. The condenser, a hot outdoor coil, releases the collected heat outside. The evaporator and condenser coils are serpentine tubing surrounded by aluminum fins. This tubing is usually made of copper.

Note: This page contains sample records for the topic "kafb kirtland air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Clean Air Act Amendments of 1990  

E-Print Network [OSTI]

Congress is currently debating amendments to the Clean Air Act which would strengthen and enhance the current Clean Air Act. The bill would guarantee a reduction of 10 million tons of sulfur dioxide from 1980 levels; would sharply reduce pollutants...

Hanneschlager, R. E.

202

Environmental History of Air Pollution and Protection  

Science Journals Connector (OSTI)

Concerns about air pollution have a long and complex history. Complaints ... of ancient Athens and Rome. But urban air quality worsened considerably during the Industrial Revolution, ... Despite the tangible natu...

Stephen Mosley

2014-01-01T23:59:59.000Z

203

Ambient Air Quality Criteria (Manitoba, Canada)  

Broader source: Energy.gov [DOE]

The Manitoba Ambient Air Quality Criteria schedule lists maximum time-based pollutant concentration levels for the protection and preservation of ambient air quality within the Province of Manitoba...

204

A New Approach to Industrial Air Conditioning  

E-Print Network [OSTI]

-dryer Systems Division, has marketed industrial drying machinery. These heat reactivated dryers can handle latent loads in industrial air conditioning systems. Through waste heat conservation, air conditioning costs can be reduced 25 to 50%, with applications...

Gravenstreter, T.

1982-01-01T23:59:59.000Z

205

Evolution of US air cargo productivity  

E-Print Network [OSTI]

This thesis provides an overview of the US air cargo industry since airline deregulation in 1978, including a brief overview of the historical evolution of air cargo transport in the US from the early 1900s until the late ...

Donatelli, David J

2012-01-01T23:59:59.000Z

206

Advanced Management of Compressed Air Systems  

Broader source: Energy.gov [DOE]

Find out how a compressed air system works and the benefits of optimal compressed air system performance. This training is designed to help end users as well as industry solution providers learn...

207

EVENT CLOUDS : lighter than air architectural structures  

E-Print Network [OSTI]

EVENT CLOUD is a versatile covering system that allows events to happen independently to weather conditions. It consists of a lighter than air pneumatic structure, filled either with helium or hot air, that covers spaces ...

Peydro Duclos, Ignacio

2014-01-01T23:59:59.000Z

208

Air America: Upholding the Airmen's Bond  

E-Print Network [OSTI]

. Ed Adams, Air America, Conducted rescue operations in Laos and South Vietnam Mr. Marius Burke, Air America, Conducted rescue operations in Laos and South Vietnam Mr. Robert Grealy, CIA, Retired Senior

Kilgard, Michael P.

209

Adverse Health Effects of Air Pollution  

E-Print Network [OSTI]

on clean air: ? 2007: Encouraging energy efficiencies, no more coal plants ? 2009: Retrofitting old coal plants and old diesel engines ? 2011: Disclosure of ?fracking? fluids injected below ground ? Alliance with Texas Business for Clean Air ? Financed...

Haley, R. W.

2011-01-01T23:59:59.000Z

210

Indoor air pollution: a public health perspective  

Science Journals Connector (OSTI)

...control tobacco smoke or gas adsorbers, air filters, and electrostatic tion by-products...ventilation air; formaldehyde sorbant filters Behavioral adjustment: Reduction in human...monitoring equipment, and performance of HVAC systems Table 4. Components of comprehensive...

JD Spengler; K Sexton

1983-07-01T23:59:59.000Z

211

Protective supplied-breathing-air garment  

DOE Patents [OSTI]

A breathing-air garment for isolating a wearer from hostile environments containing toxins or irritants is disclosed. The garment includes a suit and a separate head-protective enclosure or hood engaging a suit collar in sealing attachment. The hood and suit collar are cylindrically shaped and dimensioned to enable the wearer to withdraw his hands from the suit sleeves to perform manual tasks within the hood interior. Breathing air is supplied from an external air line with an air-delivery hose attached to the hood interior. The hose feeds air into an annular halo-like fiber-filled plenum having spaced discharge orifices attached to the hood top wall. A plurality of air exhaust/check valves located at the suit extremities cooperate with the hood air-delivery system to provide a cooling flow of circulating air from the hood throughout the suit interior. A suit entry seal provided on the suit sealed with an adhesive sealing flap.

Childers, E.L.; von Hortenau, E.F.

1982-05-28T23:59:59.000Z

212

Air pollution: Clean up our skies  

Science Journals Connector (OSTI)

... SLCPs cause poor air quality and are responsible for respiratory and cardiovascular diseases. Particulate matter in the atmosphere ... . Particulate matter in the atmosphere is the leading environmental cause of ill health, and air ...

Julia Schmale; Drew Shindell; Erika von Schneidemesser; Ilan Chabay; Mark Lawrence

2014-11-19T23:59:59.000Z

213

Compressed Air Energy Storage for Offshore  

E-Print Network [OSTI]

transmitting peak power levels. A solution to these issues is a novel high-efficiency compressed air energy

Perry Y. Li; Eric Loth; Terrence W. Simon; James D. Van De Ven; Stephen E. Crane

2011-01-01T23:59:59.000Z

214

Preventive Maintenance Strategies for Compressed Air Systems  

Broader source: Energy.gov [DOE]

This tip sheet discusses preventive maintenance strategies for compressed air systems to avoid high equipment repair and replacement costs.

215

Capturing Carbon Dioxide From Air  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Capturing Carbon Dioxide From Air Capturing Carbon Dioxide From Air Klaus S. Lackner (kl2010@columbia.edu; 212-854-0304) Columbia University 500 West 120th Street New York, NY 10027 Patrick Grimes (pgrimes@worldnet.att.net; 908-232-1134) Grimes Associates Scotch Plains, NJ 07076 Hans-J. Ziock (ziock@lanl.gov; 505-667-7265) Los Alamos National Laboratory P.O.Box 1663 Los Alamos, NM 87544 Abstract The goal of carbon sequestration is to take CO 2 that would otherwise accumulate in the atmosphere and put it in safe and permanent storage. Most proposed methods would capture CO 2 from concentrated sources like power plants. Indeed, on-site capture is the most sensible approach for large sources and initially offers the most cost-effective avenue to sequestration. For distributed, mobile sources like cars, on-board capture at affordable cost would not be

216

Clean Air Act, Section 309  

Broader source: Energy.gov (indexed) [DOE]

CLEAN AIR ACT § 309* CLEAN AIR ACT § 309* §7609. Policy review (a) The Administrator shall review and comment in writing on the environmental impact of any matter relating to duties and responsibilities granted pursuant to this chapter or other provisions of the authority of Administrator, contained in any (1) legislation proposed by any Federal department or agency, (2) newly authorized Federal projects for construction and any major Federal agency action (other than a project for construction) to which section 4332(2)(C) of this title applies, and (3) proposed regulations published by any department or agency of the Federal Government. Such written comment shall be made public at the conclusion of any such review. (b) In the event the Administrator determines that any such legislation, action, or regulation

217

NETL: Air Quality III Conference  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Air Quality III Conference - September 12, 2002 Air Quality III Conference - September 12, 2002 Table of Contents Disclaimer Papers and Presentations Disclaimer This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government or any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof.

218

Airvest's Breath of Fresh Air  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

7 7 The Cutting Edge: Airvest's Breath of Fresh Air Spray booths are a common sight in the industrial sector. Designed to remove pollutants during industrial processes such as spray painting or welding, a booth is a rectangular enclosure open on one side where the worker stands, and equipped on the opposite wall with a fan and filter arrangement to suck away the dirty air. The full-size mannequin in these photographs simulates a worker in a spray booth facing the exhaust filters. In experiments designed by LBL researcher Ashok Gadgil, smoke was released in front of the mannequin to simulate the spraying of paint in the booth. The photo on the left shows the spray booth during standard operation. The smoke-representing a pollutant-is entrained in the eddy that forms in

219

Making Li-air batteries rechargeable: material challenges. |...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Li-air batteries rechargeable: material challenges. Making Li-air batteries rechargeable: material challenges. Abstract: A Li-air battery could potentially provide three to five...

220

Health effects of air pollution: some historical notes.  

E-Print Network [OSTI]

that was his first air pollution health effects committeeand direction of air pollution health effects research inof community air pollution, including health ef- fects, has

Whittenberger, J L

1989-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "kafb kirtland air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Assessments of biofuel sustainability: air pollution and health impacts  

E-Print Network [OSTI]

Sustainability: Air Pollution and Health Impacts By Chi-and indirect air-pollution and health impacts throughout theparticularly air pollution and health impacts. In this

Tsao, Chi-Chung

2012-01-01T23:59:59.000Z

222

High-Efficiency Window Air Conditioners - Building America Top...  

Broader source: Energy.gov (indexed) [DOE]

Window Air Conditioners - Building America Top Innovation This photo shows a window air conditioning unit in place in a window frame. Window air conditioners are inexpensive,...

223

New indicator approaches for effective urban air quality management  

Science Journals Connector (OSTI)

Measurements of urban air quality at monitoring stations in developed countries have frequently involved the criteria gaseous pollutants, particulates, hazardous air pollutants, perceived air quality and relev...

Peter J. Peterson; W. Peter Williams

1999-12-01T23:59:59.000Z

224

2011: Air Quality Regulations Report | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

: Air Quality Regulations Report 2011: Air Quality Regulations Report 2011 Air Quality Regulations ReportA120911.pdf More Documents & Publications 2011...

225

HVAC Cabinet Air Leakage Test Method - Building America Top Innovation...  

Energy Savers [EERE]

their air sealing practices to reduce the amount of air leaking at ducts and duct boots, testing showed that distribution systems still leaked at air handlers and furnace...

226

Building America Top Innovations 2014 Profile: HVAC Cabinet Air...  

Energy Savers [EERE]

their air sealing practices to reduce the amount of air leaking at ducts and duct boots, testing showed that distribution systems still leaked at air handlers and furnace...

227

A comparison between two underfloor air distribution (UFAD) design tools  

E-Print Network [OSTI]

TWO UNDERFLOOR AIR DISTRIBUTION (UFAD) DESIGN TOOLS Bin CHENunderfloor air distribution (UFAD) design tools (ASHRAE RP-air distribution (UFAD), Cooling load, Design tool, HVAC

Chen, Bin; Schiavon, Stefano; Bauman, Fred S; Chen, Qingyan

2014-01-01T23:59:59.000Z

228

Fact Sheet: Isothermal Compressed Air Energy Storage (October...  

Broader source: Energy.gov (indexed) [DOE]

Isothermal Compressed Air Energy Storage (October 2012) Fact Sheet: Isothermal Compressed Air Energy Storage (October 2012) SustainX will demonstrate an isothermal compressed air...

229

Comparing air quality impacts of hydrogen and gasoline  

E-Print Network [OSTI]

Protection Agency, 2006. Air Quality System (AQS). USpathways on urban air quality. International Journal ofchanges in urban air quality. Only primary pollutants

Sperling, Dan; Wang, Guihua; Ogden, Joan M.

2008-01-01T23:59:59.000Z

230

INDOOR AIR QUALITY MEASUREMENTS IN ENERGY EFFICIENT BUILDINGS  

E-Print Network [OSTI]

of Engineering, Coordinating Committee of Air QualityStandards: Air Quality and Automobile Emission Control, Vol.of ilitrogen Dioxide Air Quality Standards. Paper tlo. 76-

Hollowell, C.D.

2011-01-01T23:59:59.000Z

231

Control of Computer Room Air Conditioning using IT Equipment Sensors  

E-Print Network [OSTI]

control routine to adjust setpoints for supply air temperaturecontrol routine to adjust setpoints for supply air temperaturesupply air temperature is provided. The fan-speed control

Bell, Geoffrey C.

2010-01-01T23:59:59.000Z

232

Hybrid and Advanced Air Cooling | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Hybrid and Advanced Air Cooling Hybrid and Advanced Air Cooling Hybrid and Advanced Air Cooling presentation at the April 2013 peer review meeting held in Denver, Colorado....

233

Making Compressed Air System Decisions  

E-Print Network [OSTI]

. Today, modern, high quality manufacturing facilities require a more scientific approach. Many manufacturing processes require strict controls over compressed air pressure, temperature and purity levels. Competitive pressures also force manufacturers...-lubricated cylinder designs. Reciprocating compressor designs remained the standard for industry until the mid 1970s. During the late 1960s and early 1970s, material and manufacturing advances led to the development of 219 Ingersoll-Rand Co. Davidson, N...

Porri, R. E.

234

Mold: An Indoor Air Pollutant  

E-Print Network [OSTI]

threat. Molds are fungi that produce microscopic cells called spores. Mold spores are present everywhere both outdoors and indoors and spread easily through the air. The most common ?problem? mold in indoor environments is Stachybotrys atra (also called S... is kept dry and clean, and efforts are made to reduce the level of mold spores entering the home. Controlling moisture. To control mold for good, you must solve any moisture problems in your home. Because there are mold spores everywhere, and mold grows...

Harris, Janie

2002-07-08T23:59:59.000Z

235

Physiological responses to air pollutants G. Halbwachs  

E-Print Network [OSTI]

Physiological responses to air pollutants G. Halbwachs Zentrum fur Umwelt- und Naturschutz of fumigation experiments on young plants could be utilized for inter- preting some effects when air pollution of the interaction between air pollution and the forest ecosystem, where not only emission stress is at hand

Boyer, Edmond

236

Air Chemistry and Pollution Spring 2014  

E-Print Network [OSTI]

ATOC 3500 Air Chemistry and Pollution Spring 2014 Meeting: T/Th, 12:30 ­ 1:45 am; Duane G1B25 in the news; for example, the quality of the air we breathe directly affects our health. In addition to mitigate the effects of air pollution. Finally, we examine some recent examples of atmospheric chemical

Toohey, Darin W.

237

Scottish Air Pollution and Health Workshop  

E-Print Network [OSTI]

Scottish Air Pollution and Health Workshop Session 4 Joint Research Policy Needs and Interactions needs and how can we work together effectively on these to reduce the adverse effects of air pollution together effectively on these to reduce the adverse effects of air pollution in Scotland. Modelling

238

Strategy Guideline: Compact Air Distribution Systems  

SciTech Connect (OSTI)

This Strategy Guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. Traditional systems sized by 'rule of thumb' (i.e., 1 ton of cooling per 400 ft2 of floor space) that 'wash' the exterior walls with conditioned air from floor registers cannot provide appropriate air mixing and moisture removal in low-load homes. A compact air distribution system locates the HVAC equipment centrally with shorter ducts run to interior walls, and ceiling supply outlets throw the air toward the exterior walls along the ceiling plane; alternatively, high sidewall supply outlets throw the air toward the exterior walls. Potential drawbacks include resistance from installing contractors or code officials who are unfamiliar with compact air distribution systems, as well as a lack of availability of low-cost high sidewall or ceiling supply outlets to meet the low air volumes with good throw characteristics. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

Burdick, A.

2013-06-01T23:59:59.000Z

239

NOAA Air Resources Laboratory Quarterly Activity Report  

E-Print Network [OSTI]

and Hawaii Meteorological Grids for NCEP Atmospheric Turbulence and Diffusion Division 18. Climate 19. Air for Europe convention on Long-Range Transport of Air Pollution. o.russell.bullock@noaa.gov 3. CarbonNOAA Air Resources Laboratory Quarterly Activity Report (January ­ March 2008) Contents Highlights

240

Air Potato Management in Your Backyard  

E-Print Network [OSTI]

Air Potato Management in Your Backyard Ridding your property of air potatoes is no easy task - Collect air potatoes that have fallen to the ground. They may still be attached to dead vines, so pulling the vines down could result in more potatoes falling. SPRING - Look for newly sprouting vines and follow

US Army Corps of Engineers

Note: This page contains sample records for the topic "kafb kirtland air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

STATE OF CALIFORNIA AIR ECONOMIZER CONTROLS ACCEPTANCE  

E-Print Network [OSTI]

STATE OF CALIFORNIA AIR ECONOMIZER CONTROLS ACCEPTANCE CEC-MECH-5A (Revised 08/09) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF ACCEPTANCE MECH-5A NA7.5.4 Air Economizer Controls Acceptance (Page 1 AIR ECONOMIZER CONTROLS ACCEPTANCE CEC-MECH-5A (Revised 08/09) CALIFORNIA ENERGY COMMISSION

242

Alternative transportation fuels and air quality  

Science Journals Connector (OSTI)

Alternative transportation fuels and air quality ... Potential Air Quality Effects of Using Ethanol?Gasoline Fuel Blends: A Field Study in Albuquerque, New Mexico ... Potential Air Quality Effects of Using Ethanol?Gasoline Fuel Blends: A Field Study in Albuquerque, New Mexico ...

Tai Y. Chang; Robert H. Hammerle; Steven M. Japar; Irving T. Salmeen

1991-07-01T23:59:59.000Z

243

3, 35433588, 2003 3-D air pollution  

E-Print Network [OSTI]

ACPD 3, 3543­3588, 2003 3-D air pollution modelling L. M. Frohn et al. Title Page Abstract hemispheric nested air pollution model L. M. Frohn, J. H. Christensen, J. Brandt, C. Geels, and K. M. Hansen 2003 Correspondence to: L. M. Frohn (lmf@dmu.dk) 3543 #12;ACPD 3, 3543­3588, 2003 3-D air pollution

Boyer, Edmond

244

Air Pollution, ATS555 Colorado State University  

E-Print Network [OSTI]

the basic chemistry of the atmosphere and how it contributes to secondary pollutant formation. 5. Consider/Air Pollution History pp. 1-5 Air Pollution Types, Atmospheric Composition, Concentrations, and Sources pp. 5Air Pollution, ATS555 Colorado State University Fall 2014 Mondays and Wednesdays @ 4:00 ­ 5:30 Room

Collett Jr., Jeffrey L.

245

Air Quality Standards & ATOC/CHEM 5151  

E-Print Network [OSTI]

1 Lecture 22 Air Quality Standards & Control ATOC/CHEM 5151 #12;2 Primary Pollutants Things to reduce air pollution emissions ­ Latest version ­ 1990 (original, 1963) ­ What is an "air pollutant that are directly emitted Nitrogen Oxides (NOx) Hydrocarbons (VOCs) Carbon Monoxide (CO) #12;3 Secondary Pollutants

Toohey, Darin W.

246

Air Corrosivity in U.S. Outdoor-Air-Cooled Data Centers is Similar to That  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Air Corrosivity in U.S. Outdoor-Air-Cooled Data Centers is Similar to That Air Corrosivity in U.S. Outdoor-Air-Cooled Data Centers is Similar to That in Conventional Data Centers Title Air Corrosivity in U.S. Outdoor-Air-Cooled Data Centers is Similar to That in Conventional Data Centers Publication Type Report LBNL Report Number LBNL-4951E Year of Publication 2011 Authors Coles, Henry C., Tae Won Han, Phillip N. Price, Ashok J. Gadgil, and William F. Tschudi Date Published 03/2011 Abstract There is a concern that environmental-contamination caused corrosion may negatively affect Information Technology (IT) equipment reliability. Nineteen data centers in the United States and two in India were evaluated using Corrosion Classification Coupons (CCC) to assess environmental air quality as it may relate IT equipment reliability. The data centers were of two basic types: "closed" and outside-air cooled. A closed data center provides cool air to the IT equipment using air conditioning in which only a small percentage of the recirculation air is "make-up" air continuously supplied from outside to meet human health requirements. An outside-air cooled data center uses outside air directly as the primary source for IT equipment cooling. Corrosion measuring coupons containing copper and silver metal strips were placed in both "closed" and outside-air cooled data centers. The coupons were placed at each data center (closed and outside-air cooled types) with the location categorized into three groups:

247

Sensitivity of forced air distribution system efficiency to climate, duct location, air leakage and insulation  

E-Print Network [OSTI]

Location, Air Leakage and Insulation Iain S. Walker Energy4 Duct Insulation, Location and Leakageinsulation

Walker, Iain

2001-01-01T23:59:59.000Z

248

Influence of air conditioning management on heat island in Paris air street temperatures  

E-Print Network [OSTI]

Influence of air conditioning management on heat island in Paris air street temperatures Brice 2012 Available online 13 March 2012 Keywords: Air conditioning Heat island mitigation Urban heat island killer'', is exacerbated in urban areas owing to the heat island effect. Air conditioning (A/C) is a key

Ribes, Aurélien

249

Ethylenediamine at Air/Liquid and Air/Silica Interfaces: Protonation  

E-Print Network [OSTI]

surface and EDA protonated products at air/liquid interfaces. The SFG spectra of EDA adsorbedEthylenediamine at Air/Liquid and Air/Silica Interfaces: Protonation Versus Hydrogen BondingKa (HOSit)) is between the two pKa values of EDA (in the range of 7.56-10.71) at the air/silica interface

250

E-Print Network 3.0 - air temperature air Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

State University Collection: Mathematics 12 Connectable solar air collectors Solar Energy Centre Denmark Summary: ......

251

Optimal supply air temperature with respect to energy use in a variable air volume system  

Science Journals Connector (OSTI)

In a variable air volume (VAV) system with 100% outdoor air, the cooling need in the building is satisfied with a certain air flow at a certain supply air temperature. To minimize the system energy use, an optimal supply air temperature can be set dependent on the load, specific fan power (SFP), chiller coefficient of performance, outdoor temperature and the outdoor relative humidity. The theory for an optimal supply air temperature is presented and the heating, ventilation and air-conditioning (HVAC) energy use is calculated depending on supply air temperature control strategy, average U-value of the building envelope and two outdoor climates. The analyses show that controlling the supply air temperature optimally results in a significantly lower HVAC energy use than with a constant supply air temperature. The optimal average U-value of the building envelope is in practise mostly zero.

Fredrik Engdahl; Dennis Johansson

2004-01-01T23:59:59.000Z

252

Final Environmental Assessment for the Test Capabilities Revitalization at Sandia National Laboratories/New Mexico  

Broader source: Energy.gov (indexed) [DOE]

6 6 Final Environmental Assessment for the Test Capabilities Revitalization at Sandia National Laboratories/New Mexico D E P A R T M E N T O F E N E R G Y U N I T E D S T A T E S O F A M E R I C A January 2003 Department of Energy, Office of Kirtland Site Operations Kirtland Air Force Base, Albuquerque New Mexico Test Capabilities Revitalization Environmental Assessment January 2003 Department of Energy Office of Kirtland Site Operations i TABLE OF CONTENTS 1.0 PURPOSE AND NEED FOR AGENCY ACTION ........................................................... 1 2.0 NO ACTION AND PROPOSED ACTION ALTERNATIVES........................................ 2 2.1 EXISTING FACILITIES ...........................................................................................................

253

Meteorological Effects on Air/Fuel Ratio  

E-Print Network [OSTI]

1. "Temperature Compensat d Air/Fuel Ratio Control on a Recuperated Furnace," by J. L. Ferri. GTE Products Corporation, Towanda, PA, lECTC '83 2. Chemical Engineers Handbook, PerTY and Chilton, 5th ed.., (McGraw Hlln, p. 12-7. 3. "Technology..., E = (100 ... 10) (ill) - 100 = 17.2% excess a . 2 Example 2 A furnace uses recuperators which prehe~t the combustion air to 1200 OF using 30 OF air. WithJlOO OF air, the preheated air temperature will be approxIjrnately 1270 OF, a 70 OF increase...

Ferri, J. L.

1984-01-01T23:59:59.000Z

254

Air Sealing Your Home | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Your Home Your Home Air Sealing Your Home November 26, 2013 - 6:22pm Addthis Save on heating and cooling costs by checking for air leaks in common trouble spots in your home. Save on heating and cooling costs by checking for air leaks in common trouble spots in your home. What does this mean for me? Save money and energy by air sealing your house. Caulking and weatherstripping are simple, effective ways of sealing air leaks in your home. Reducing the amount of air that leaks in and out of your home is a cost-effective way to cut heating and cooling costs, improve durability, increase comfort, and create a healthier indoor environment. Caulking and weatherstripping are two simple and effective air-sealing techniques that offer quick returns on investment, often one year or less. Caulk is

255

Air Products Chemicals Inc | Open Energy Information  

Open Energy Info (EERE)

Air Products Chemicals Inc Air Products Chemicals Inc Jump to: navigation, search Name Air Products & Chemicals Inc Place Allentown, Pennsylvania Zip 18195 Sector Hydro, Hydrogen, Services Product A global supplier of merchant hydrogen with a portfolio of products, services and solutions providing gases, performance materials and chemical intermediates. References Air Products & Chemicals Inc[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Air Products & Chemicals Inc is a company located in Allentown, Pennsylvania . References ↑ "Air Products & Chemicals Inc" Retrieved from "http://en.openei.org/w/index.php?title=Air_Products_Chemicals_Inc&oldid=341937

256

Tips: Air Conditioners | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Tips: Air Conditioners Tips: Air Conditioners Tips: Air Conditioners June 24, 2013 - 6:31pm Addthis Bigger isn't always better for an air conditioner. Learn effective ways to stay cool while saving energy. | Photo courtesy of ©iStockphoto/galinast. Bigger isn't always better for an air conditioner. Learn effective ways to stay cool while saving energy. | Photo courtesy of ©iStockphoto/galinast. Buying a bigger room air conditioner won't necessarily make you feel more comfortable during the hot summer months. In fact, a room air conditioner that's too big for the area it is supposed to cool will perform less efficiently and less effectively than a smaller, properly sized unit. The reason: an oversized unit will cool the room(s) to the thermostat set-point before proper dehumidification occurs, making the area feel "clammy"

257

Clean Air Act | Open Energy Information  

Open Energy Info (EERE)

Clean Air Act Clean Air Act Jump to: navigation, search Statute Name Clean Air Act Year 1970 Url CAA.jpg Description Congress passed the CAA in 1970 in order to combat air pollution in the United States and protect the health and general welfare of United States citizens against air pollutants. References CAA[1] Federal Oil and Gas[2] Contents 1 Introduction 2 Title I Air Pollution Prevention 3 Title II Emission Standards for Moving Sources 4 Title III General Provisions 5 Title IV Acid Deposition Control 6 Title V Permits 7 Title VI Stratospheric Ozone Protection 8 References Introduction The Clean Air Act was enacted by congress in 1990. Since then only minor changes have been made. The act is just a law ensuring that the EPA will follow certain guidelines and definitions for protecting and improving the

258

Industrial Compressed Air System Energy Efficiency Guidebook.  

SciTech Connect (OSTI)

Energy efficient design, operation and maintenance of compressed air systems in industrial plants can provide substantial reductions in electric power and other operational costs. This guidebook will help identify cost effective, energy efficiency opportunities in compressed air system design, re-design, operation and maintenance. The guidebook provides: (1) a broad overview of industrial compressed air systems, (2) methods for estimating compressed air consumption and projected air savings, (3) a description of applicable, generic energy conservation measures, and, (4) a review of some compressed air system demonstration projects that have taken place over the last two years. The primary audience for this guidebook includes plant maintenance supervisors, plant engineers, plant managers and others interested in energy management of industrial compressed air systems.

United States. Bonneville Power Administration.

1993-12-01T23:59:59.000Z

259

Chapter 28 - Air Quality Status and Trends  

Science Journals Connector (OSTI)

Abstract This chapter describes the condition of air quality, based on air pollutant concentrations, i.e. criteria pollutants, in airsheds around the world, as well as certain air toxics in urban areas and hot spots. The variability of pollutant concentrations in space and time are discussed, as well as differences in air pollution between more industrialized and economically developed regions vs developing nations. The status and trends of atmospheric concentrations of tropospheric ozone, oxides of nitrogen, oxides of sulfur, carbon monoxide, lead, and particulate matter are discussed. Examples of air toxics include benzene, polycyclic aromatic hydrocarbons, dioxins, aldehydes, and metals, e.g. mercury. Regional and global trends include acid deposition, depletion of the stratospheric ozone layer, and climate change. Indoor air quality is discussed. The chapter concludes with a description of an air quality index.

Daniel Vallero

2014-01-01T23:59:59.000Z

260

Tips: Air Conditioners | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Tips: Air Conditioners Tips: Air Conditioners Tips: Air Conditioners June 24, 2013 - 6:31pm Addthis Bigger isn't always better for an air conditioner. Learn effective ways to stay cool while saving energy. | Photo courtesy of ©iStockphoto/galinast. Bigger isn't always better for an air conditioner. Learn effective ways to stay cool while saving energy. | Photo courtesy of ©iStockphoto/galinast. Buying a bigger room air conditioner won't necessarily make you feel more comfortable during the hot summer months. In fact, a room air conditioner that's too big for the area it is supposed to cool will perform less efficiently and less effectively than a smaller, properly sized unit. The reason: an oversized unit will cool the room(s) to the thermostat set-point before proper dehumidification occurs, making the area feel "clammy"

Note: This page contains sample records for the topic "kafb kirtland air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Indoor Air Quality Forms 195 Building: _________________________________________________________ File Number: ________________________________  

E-Print Network [OSTI]

acceptable? Seal when closed? #12;Indoor Air Quality Forms 196 BuildingIndoor Air Quality Forms 195 Building in relation to indoor air quality. Page 1 of 14 Needs Attention Not ApplicableOKComponent Comments Outside Air

262

Model sensitivity and uncertainty analysis using roadside air quality measurements  

E-Print Network [OSTI]

Model sensitivity and uncertainty analysis using roadside air quality measurements Sotiris, a probabilistic methodology for assessing urban air quality was proposed. Keywords: Air pollution; Model 535265 1. Introduction Mathematical modelling has been widely used for assessing ambient air quality

Paris-Sud XI, Université de

263

Control of Computer Room Air Conditioning using IT Equipment Sensors  

E-Print Network [OSTI]

8 Figure 5 Server rack Inlet Air Temperature (8 Figure 6 Server-rack Leaving Air Temperature (Rack .

Bell, Geoffrey C.

2010-01-01T23:59:59.000Z

264

Laser Noise Reduction in Air  

E-Print Network [OSTI]

Fluctuations of the white-light supercontinuum produced by ultrashort laser pulses in selfguided filaments (spatio-temporal solitons) in air are investigated. We demonstrate that correlations exist within the white-light supercontinuum, and that they can be used to significantly reduce the laser intensity noise by filtering the spectrum. More precisely, the fundamental wavelength is anticorrelated with the wings of the continuum, while conjugated wavelength pairs on both sides of the continuum are strongly correlated. Spectral filtering of the continuum reduces the laser intensity noise by 1.2 dB, showing that fluctuations are rejected to the edges of the spectrum.

Pierre Bejot; Jerome Kasparian; Estelle Salmon; Roland Ackermann; Nicolas Gisin; Jean-Pierre Wolf

2006-08-09T23:59:59.000Z

265

Sonoluminescing air bubbles rectify argon  

E-Print Network [OSTI]

The dynamics of single bubble sonoluminescence (SBSL) strongly depends on the percentage of inert gas within the bubble. We propose a theory for this dependence, based on a combination of principles from sonochemistry and hydrodynamic stability. The nitrogen and oxygen dissociation and subsequent reaction to water soluble gases implies that strongly forced air bubbles eventually consist of pure argon. Thus it is the partial argon (or any other inert gas) pressure which is relevant for stability. The theory provides quantitative explanations for many aspects of SBSL.

Detlef Lohse; Michael P. Brenner; Todd F. Dupont; Sascha Hilgenfeldt; Blaine Johnston

1996-05-07T23:59:59.000Z

266

Thermal comfort and cold air distribution  

SciTech Connect (OSTI)

Cold air distribution systems supply air at temperatures between 38 F and 51 F. Cold air distribution systems are increasingly attractive when used in conjunction with ice storage systems to shave peak load by shifting the demand to off-peak hours. They also require less operating and capital costs because they use smaller fans, ducts, piping, and pumps. However, an important issue in design and application of cold air systems is the effect on occupant comfort. There are several techniques and methodologies that practitioners use for evaluation of conventional air distribution systems. Among these is the Air Diffusion Performance Index (ADPI). It is widely used in the US and is referenced in the 1993 ASHRAE Handbook--Fundamentals. However, this technique is based on empirical correlations obtained from tests conducted with conventional systems and it cannot be guaranteed that they will be equally applicable to cold air systems. This study was undertaken, therefore, to extend the existing techniques (especially the Air Diffusion Performance Index) to applications where cold air distribution systems are utilized. This work presents a critical review of the evolution of the ADPI technique and offers several recommendations for developing a firm foundation for future room air distribution research.

Hassani, V. [National Renewable Energy Lab., Golden, CO (United States); Miller, P.L. [Miller (Paul), Arvada, CO (United States)

1998-10-01T23:59:59.000Z

267

Ambient Operation of Li/Air Batteries  

SciTech Connect (OSTI)

In this work, Li/air batteries based on nonaqueous electrolytes were investigated in ambient conditions (with an oxygen partial pressure of 0.21 atm and relative humidity of ~20%). A heat-sealable polymer membrane was used as both an oxygen-diffusion membrane and as a moisture barrier for Li/air batteries. The membrane also can minimize the evaporation of the electrolyte from the batteries. Li/air batteries with this membrane can operate in ambient conditions for more than one month with a specific energy of 362 Wh kg-1, based on the total weight of the battery including its packaging. Among various carbon sources used in this work, Li/air batteries using Ketjenblack (KB) carbon-based air electrodes exhibited the highest specific energy. However, KB-based air electrodes expanded significantly and absorbed much more electrolyte than electrodes made from other carbon sources. The weight distribution of a typical Li/air battery using the KB-based air electrode was dominated by the electrolyte (~70%). Lithium-metal anodes and KB-carbon anodes account for only 5.12% and 5.78% of the battery weight, respectively. We also found that only ~ 20% of the mesopore volume of the air electrode was occupied by reaction products after discharge. To further improve the specific energy of the Li/air batteries, the microstructure of the carbon electrode needs to be further improved to absorb much less electrolyte while still holding significant amounts of reaction products

Zhang, Jiguang; Wang, Deyu; Xu, Wu; Xiao, Jie; Williford, Ralph E.

2010-07-01T23:59:59.000Z

268

DOE Requires Air-Con International to Cease Sales of Inefficient Air  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Requires Air-Con International to Cease Sales of Inefficient Requires Air-Con International to Cease Sales of Inefficient Air Conditioners and Proposes Penalties DOE Requires Air-Con International to Cease Sales of Inefficient Air Conditioners and Proposes Penalties September 21, 2010 - 6:43pm Addthis The Department has issued a Notice of Noncompliance Determination and Proposed Civil Penalty to Air-Con, International, requiring Air-Con to cease the sale of certain air-conditioning systems in the United States and proposing a civil penalty of $231,090 for sales of these products in violation of the applicable energy efficiency standards. This action reflects the Department's continued commitment to act aggressively to remove unlawful products from the market. In March, 2010, the Department issued a subpoena requiring Air-Con to

269

Lithium-Air Battery: High Performance Cathodes for Lithium-Air Batteries  

SciTech Connect (OSTI)

BEEST Project: Researchers at Missouri S&T are developing an affordable lithium-air (Li-Air) battery that could enable an EV to travel up to 350 miles on a single charge. Todays EVs run on Li-Ion batteries, which are expensive and suffer from low energy density compared with gasoline. This new Li-Air battery could perform as well as gasoline and store 3 times more energy than current Li-Ion batteries. A Li-Air battery uses an air cathode to breathe oxygen into the battery from the surrounding air, like a human lung. The oxygen and lithium react in the battery to produce electricity. Current Li-Air batteries are limited by the rate at which they can draw oxygen from the air. The team is designing a battery using hierarchical electrode structures to enhance air breathing and effective catalysts to accelerate electricity production.

None

2010-08-01T23:59:59.000Z

270

Gas Spring Losses in Linear Clearance Seal Compressors P.B. Bailey, M.W. Dadd, J.S. Reed*  

E-Print Network [OSTI]

1 Gas Spring Losses in Linear Clearance Seal Compressors P.B. Bailey, M.W. Dadd, J.S. Reed* , C. Stevenage, U.K. Thomas M. Davis Air Force Research Laboratory Kirtland AFB, New Mexico, U.S.A ABSTRACT investigations on conventional crank driven reciprocating compressors, where the use of normal sliding seals

271

Air handling unit supply air temperature optimal control during economizer cycles  

Science Journals Connector (OSTI)

Most air handling units (AHUs) in commercial buildings have an air economizer cycle for free cooling under certain outside air conditions. During the economizer cycle, the outside air and return air dampers are modulated to seek supply air temperature at its setpoint. The supply air temperature is typically set at 55F (13C) to control humidity in the space. However, dehumidification is not necessary when the outside air is dry. Meanwhile, the space may have less cooling load due to envelope heat loss and/or occupant schedule changes. These facts provide an opportunity to use higher supply air temperature to reduce or eliminate mechanical cooling and terminal box reheat. On the contrary, a higher supply air temperature requires increased air flow as well as fan power. Therefore, an optimization question is formed, through which an optimal supply air temperature is identified to minimize total energy consumption. In this paper a steady-state energy consumption model is established for AHU systems under the economizer, and then an analytical optimization method is used to seek an optimal supply air temperature setpoint to minimize the energy cost. This paper presents AHU system energy modeling, supply air temperature optimization, simulated energy savings, and control sequence development.

Gang Wang; Li Song

2012-01-01T23:59:59.000Z

272

Air Corrosivity in U.S. Outdoor-Air-Cooled Data Centers is Similar to That in Conventional Data Centers  

E-Print Network [OSTI]

Should Data Center Owners be Afraid of Air-side Economizerdata center contamination, gaseous contamination, air-side economizer,

Coles, Henry C.

2012-01-01T23:59:59.000Z

273

Fault tolerant control of outdoor air and AHU supply air temperature in VAV air conditioning systems using PCA method  

Science Journals Connector (OSTI)

This paper presents a fault tolerant control method to control the outdoor air ventilation and AHU supply air temperature, which concerned indoor air quality and humidity, respectively to satisfy ASHRAE Standard in VAV systems. The principal component analysis method, joint angle method, and compensatory reconstruction are used to detect, isolate, and reconstruct the fault, respectively for fault tolerant control. They are tested and evaluated in a simulation environment under the condition of temperature and flow sensors with fix bias faults.

Xinqiao Jin; Zhimin Du

2006-01-01T23:59:59.000Z

274

Air Force Enhanced Use Lease  

Broader source: Energy.gov (indexed) [DOE]

1 1 Air Force Enhanced Use Lease Mr. Brian Brown 16 Oct. 12 I n t e g r i t y - S e r v i c e - E x c e l l e n c e 2 Agenda  Brian Brown  Enhanced Use Lease (EUL) Overview  Energy EULs  EUL Goals  David Swanson  Energy EUL Market Drivers  Current EUL Projects  Partnering with the Air Force  Contact Information I n t e g r i t y - S e r v i c e - E x c e l l e n c e 3 Overview  Authority 10 USC 2667  An EUL is a lease  By the government  Of "non-excess" property  Under the control of the government  To a public or private sector lessee  In exchange for fair market value rental payments in cash and/or in kind consideration I n t e g r i t y - S e r v i c e - E x c e l l e n c e

275

Air and water cooled modulator  

DOE Patents [OSTI]

A compact high power magnetic compression apparatus and method for delivering high voltage pulses of short duration at a high repetition rate and high peak power output which does not require the use of environmentally unacceptable fluids such as chlorofluorocarbons either as a dielectric or as a coolant, and which discharges very little waste heat into the surrounding air. A first magnetic switch has cooling channels formed therethrough to facilitate the removal of excess heat. The first magnetic switch is mounted on a printed circuit board. A pulse transformer comprised of a plurality of discrete electrically insulated and magnetically coupled units is also mounted on said printed board and is electrically coupled to the first magnetic switch. The pulse transformer also has cooling means attached thereto for removing heat from the pulse transformer. A second magnetic switch also having cooling means for removing excess heat is electrically coupled to the pulse transformer. Thus, the present invention is able to provide high voltage pulses of short duration at a high repetition rate and high peak power output without the use of environmentally unacceptable fluids and without discharging significant waste heat into the surrounding air.

Birx, Daniel L. (Oakley, CA); Arnold, Phillip A. (Livermore, CA); Ball, Don G. (Livermore, CA); Cook, Edward G. (Livermore, CA)

1995-01-01T23:59:59.000Z

276

Air and water cooled modulator  

DOE Patents [OSTI]

A compact high power magnetic compression apparatus and method are disclosed for delivering high voltage pulses of short duration at a high repetition rate and high peak power output which does not require the use of environmentally unacceptable fluids such as chlorofluorocarbons either as a dielectric or as a coolant, and which discharges very little waste heat into the surrounding air. A first magnetic switch has cooling channels formed therethrough to facilitate the removal of excess heat. The first magnetic switch is mounted on a printed circuit board. A pulse transformer comprised of a plurality of discrete electrically insulated and magnetically coupled units is also mounted on said printed board and is electrically coupled to the first magnetic switch. The pulse transformer also has cooling means attached thereto for removing heat from the pulse transformer. A second magnetic switch also having cooling means for removing excess heat is electrically coupled to the pulse transformer. Thus, the present invention is able to provide high voltage pulses of short duration at a high repetition rate and high peak power output without the use of environmentally unacceptable fluids and without discharging significant waste heat into the surrounding air. 9 figs.

Birx, D.L.; Arnold, P.A.; Ball, D.G.; Cook, E.G.

1995-09-05T23:59:59.000Z

277

General Air Permits (Louisiana) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

General Air Permits (Louisiana) General Air Permits (Louisiana) General Air Permits (Louisiana) < Back Eligibility Agricultural Construction Industrial Investor-Owned Utility Municipal/Public Utility Rural Electric Cooperative Utility Program Info State Louisiana Program Type Environmental Regulations Provider Louisiana Department of Environmental Quality Any source, including a temporary source, which emits or has the potential to emit any air contaminant requires an air permit. Facilities with potential emissions less than 5 tons per year of any regulated air pollutant do not need a permit. The Louisiana Department of Environmental Quality issues Title V General Permits. The permit is developed based on equipment types versus facility types, the general permits are not limited in their use to a specific industry or category. Title V permits combine

278

University of Colorado Indoor Air Quality Report  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Image Courtesy of Ohio Image Courtesy of Ohio State University INDOOR AIR QUALITY Design Goals Design Goals Design Goals Design Goals Integrate technologically and economically innovative, low-energy strategies Minimize occupant distraction User-friendly controls Minimize pollutant sources Bio Bio Bio Bio- - - -S S S S ( ( ( (h h h h) ) ) ) ip ip ip ip indoor air quality features indoor air quality features indoor air quality features indoor air quality features Mechanical Systems Energy Recovery Ventilator Exhaust Fans Heating And Cooling Systems Passive Ventilation Low VOC materials Each of these features is described in more detail below. Mechanical Systems Energy Recovery Ventilator Knowing that our home has a tight envelope, due to our Bio-SIP construction, we needed to use mechanical ventilation to ensure suitable indoor air

279

NETL: IEP - Air Quality Research: Regulatory Drivers  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Regulatory Drivers Regulatory Drivers DOE/NETL’s Air Quality Research Program is in direct response to the need to ensure that fossil-fuel-fired power systems continue to meet current and future environmental requirements. Specific environmental regulatory requirements driving this research are briefly summarized below: I. Clean Air Act (Including 1990 Amendments) Title I - Air Pollution Prevention and Control Part A - Air Quality and Emission Limitations Sect. 109 - National Ambient Air Quality Standards In July 1997 EPA promulgated new standards for particulate matter finer than 2.5 micrometers (PM2.5) and revised the ambient ozone standards. Sect. 111 - Standards of Performance for New Stationary Sources Part C - Prevention of Significant Deterioration of Air Quality

280

Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning |  

Broader source: Energy.gov (indexed) [DOE]

Desiccant Enhanced Evaporative Air Conditioning Desiccant Enhanced Evaporative Air Conditioning Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning May 29, 2012 - 5:22pm Addthis This breakthrough combines desiccant materials, which remove moisture from the air using heat, and advanced evaporative technologies to develop a cooling unit that uses 90 percent less electricity and up to 80 percent less total energy than traditional air conditioning. This solution, called the desiccant enhanced evaporative air conditioner (DEVAP), also controls humidity more effectively to improve the comfort of people in buildings. View the entire Lab Breakthrough playlist. What are the key facts? Recent materials advances and liquid desiccant advances to design the compact and cost-effective DEVAP system. DEVAP uses 90 percent less electricity and up to 80 percent less

Note: This page contains sample records for the topic "kafb kirtland air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning |  

Broader source: Energy.gov (indexed) [DOE]

Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning May 29, 2012 - 5:22pm Addthis This breakthrough combines desiccant materials, which remove moisture from the air using heat, and advanced evaporative technologies to develop a cooling unit that uses 90 percent less electricity and up to 80 percent less total energy than traditional air conditioning. This solution, called the desiccant enhanced evaporative air conditioner (DEVAP), also controls humidity more effectively to improve the comfort of people in buildings. View the entire Lab Breakthrough playlist. What are the key facts? Recent materials advances and liquid desiccant advances to design the compact and cost-effective DEVAP system.

282

Room air monitor for radioactive aerosols  

DOE Patents [OSTI]

A housing assembly for use with a room air monitor for simultaneous collection and counting of suspended particles includes a casing containing a combination detector-preamplifier system at one end, a filter system at the other end, and an air flow system consisting of an air inlet formed in the casing between the detector-preamplifier system and the filter system and an air passageway extending from the air inlet through the casing and out the end opposite the detector-preamplifier combination. The filter system collects suspended particles transported directly through the housing by means of the air flow system, and these particles are detected and examined for radioactivity by the detector-preamplifier combination. 2 figs.

Balmer, D.K.; Tyree, W.H.

1987-03-23T23:59:59.000Z

283

Heating, Ventilation and Air Conditioning Efficiency  

Broader source: Energy.gov (indexed) [DOE]

Presented By: WALTER E. JOHNSTON, PE Presented By: WALTER E. JOHNSTON, PE CEM, CEA, CLEP, CDSM, CPE Air Conditioning (HVAC) system is to provide and maintain a comfortable environment within a building for the occupants or for the process being conducted Many HVAC systems were not designed with energy efficiency as one of the design factors 3 Air Air is the major conductor of heat. Lack of heat = air conditioning OR 4 Btu - Amount of heat required to raise one pound of water 1 F = 0.252 KgCal 1 Pound of Water = About 1 Pint of Water ~ 1 Large Glass 1 Kitchen Match Basics of Air Conditioning = 1 Btu 5 = 6 Low Cost Cooling Unit 7 8 Typical Design Conditions 75 degrees F temperature 50% relative humidity 30 - 50 FPM air movement

284

Radionuclide Air Emission Report for 2011  

E-Print Network [OSTI]

470E-201 Radionuclide Air Emission Report for Prepared by:Environmental Protection Agency, National Emission Standardsfor Emissions of Radionuclides Other Than Radon From

Wahl, Linnea

2012-01-01T23:59:59.000Z

285

Room Air Conditioners | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Test Results roomairconditioner v1.6.xlsx More Documents & Publications Commercial Air Conditioners and Heat Pumps Fluorescent Lamp Ballasts Residential Condensing Gas Furnaces...

286

Liquid phase thermal swing chemical air separation  

DOE Patents [OSTI]

A temperature swing absorption separation of oxygen from air is performed with an oxygen acceptor of alkali metal nitrate and nitrite. 2 figs.

Erickson, D.C.

1988-05-24T23:59:59.000Z

287

Liquid phase thermal swing chemical air separation  

DOE Patents [OSTI]

A temperature swing absorption separation of oxygen from air is performed with an oxygen acceptor of alkali metal nitrate and nitrite.

Erickson, Donald C. (Annapolis, MD)

1988-01-01T23:59:59.000Z

288

Regulations for Air Quality (Quebec, Canada)  

Broader source: Energy.gov [DOE]

This Regulation establishes emission standards for particulates and gases, emission opacity standards, standards of air quality and control measures to prevent, eliminate or reduce the emission of...

289

BUILDING VENTILATION AND INDOOR AIR QUALITY  

E-Print Network [OSTI]

monoxide and nitrogen dioxide from gas appliances;health, indoor air quality, nitrogen dioxide, radon The workin residen- (CO), nitrogen dioxide (NOz), formaldehyde (

Hollowell, C.D.

2012-01-01T23:59:59.000Z

290

Ellsworth Air Force Base Advanced Metering Project  

Broader source: Energy.gov [DOE]

Presentation covers the Ellsworth Air Force Base Advanced Metering project and is given at the Spring 2010 Federal Utility Partnership Working Group (FUPWG) meeting in Providence, Rhode Island.

291

AltAir Fuels | Open Energy Information  

Open Energy Info (EERE)

to: navigation, search Name: AltAir Fuels Place: Seattle, Washington Sector: Renewable Energy Product: Seattle-based developer of projects for the production of jet fuel from...

292

Energy performance of underfloor air distribution systems  

E-Print Network [OSTI]

UnderfloorAirDistribution(UFAD)DesignGuide. Atlanta:distribution,UFAD,EnergyPlus,EnergyPlus/UFAD,energy modeling,designdesigncalculationsmustaccountforthedistributionof

Bauman, Fred; Webster, Tom; Linden, Paul; Buhl, Fred

2007-01-01T23:59:59.000Z

293

Compressed Air Energy Storage Act (Kansas)  

Broader source: Energy.gov [DOE]

This act lays out regulations for the local authorities related to site selection, design, operation and monitoring for underground storage of compressed air.

294

Air Products Hydrogen Energy Systems  

Broader source: Energy.gov (indexed) [DOE]

Kiczek,Edward F. [KICZEKEF@airproducts.com] Kiczek,Edward F. [KICZEKEF@airproducts.com] Sent: Monday, April 18, 2011 7:40 PM To: Gopstein, Avi (S4) Subject: Hydrogen Infrastructure Latest Advancements Attachments: Air Products Written Comments to 2011 2012 AB118 Investment Plan.pdf Follow Up Flag: Follow up Flag Status: Flagged Categories: QTR Transparency Avi, You may recall we met in DC when the McKinsey team from Germany came to discuss the EU study on hydrogen infrastructure. At that time I mention a significant advance in infrastructure that would be announced soon. Attached is our testimony to the California Energy Commission on deploying that technology. We were awarded the project to build 9 stations in southern California with the backing of

295

Enclosed rotary disc air pulser  

DOE Patents [OSTI]

An enclosed rotary disc air pulser for use with a solvent extraction pulse olumn includes a housing having inlet, exhaust and pulse leg ports, a shaft mounted in the housing and adapted for axial rotation therein, first and second disc members secured to the shaft within the housing in spaced relation to each other to define a chamber therebetween, the chamber being in communication with the pulse leg port, the first disc member located adjacent the inlet port, the second disc member being located adjacent the exhaust port, each disc member having a milled out portion, the disc members positioned on the shaft so that as the shaft rotates, the milled out portions permit alternative cyclical communication between the inlet port and the chamber and the exhaust port and the chamber.

Olson, A. L. (Idaho Falls, ID); Batcheller, Tom A. (Idaho Falls, ID); Rindfleisch, J. A. (Arco, ID); Morgan, John M. (Arco, ID)

1989-01-01T23:59:59.000Z

296

DOE Takes Action to Stop the Sales of Air-Con Air Conditioner Models Shown  

Broader source: Energy.gov (indexed) [DOE]

Takes Action to Stop the Sales of Air-Con Air Conditioner Takes Action to Stop the Sales of Air-Con Air Conditioner Models Shown to Violate Federal Energy Efficiency Appliance Standards DOE Takes Action to Stop the Sales of Air-Con Air Conditioner Models Shown to Violate Federal Energy Efficiency Appliance Standards September 23, 2010 - 12:00am Addthis Washington, DC - The Department of Energy announced today that it has taken action against Air-Con, International, requiring the company to stop selling certain air conditioning systems in the U.S. that have been shown to violate minimum energy efficiency appliance standards. DOE is proposing a civil penalty of more than $230,000 for importing and distributing these inefficient cooling products. This action and the proposed penalties are part of the Department's continued commitment to act aggressively to remove

297

Optimal Supply Angle of Upside Air Supply in Manned Spacecraft Cabin-Based Air Age  

E-Print Network [OSTI]

The age of air in the workaround of a manned spacecraft cabin that contain astronauts, apparatus and simple living establishments was numerically simulated by use of commercial software and a standard k-e turbulence model. An air inlet installed...

Liang, Z.; Zhang, J.; Lu, Y.

2006-01-01T23:59:59.000Z

298

Development of Novel Nanomaterials for Lithium-Air and Sodium-Air Batteries.  

E-Print Network [OSTI]

??Lithium-air and sodium-air batteries are promising energy storage systems for future smart grids and electric vehicles due to their extremely high theoretical energy densities. However, (more)

Li, Yongliang

2013-01-01T23:59:59.000Z

299

EPA Air Pollution and the Clean Air Act Webpage | Open Energy...  

Open Energy Info (EERE)

Webpage Jump to: navigation, search OpenEI Reference LibraryAdd to library Web Site: EPA Air Pollution and the Clean Air Act Webpage Abstract This webpage provides information on...

300

Energy performance of air distribution systems part II: room air stratification full scale testing  

E-Print Network [OSTI]

and are connected to a fan coil unit by flexible ductwork asvariable air volume fan coil units typically used in

Webster, Tom; Lukaschek, Wolfgang; Dickeroff, Darryl; Bauman, Fred

2007-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "kafb kirtland air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Altering heavy vehicle air suspension dynamic forces by modifying air lines  

Science Journals Connector (OSTI)

An experimental programme in 2007 used three air-suspended Heavy Vehicles (HVs) travelling over typical urban roads to determine whether dynamic axle-to-chassis forces could be reduced by using larger-than-standard diameter longitudinal air lines. This paper presents methodology, interim analysis and partial results from that program. Alterations to dynamic measures derived from axle-to-chassis forces with standard-sized longitudinal air lines vs. larger longitudinal air lines fitted are presented and discussed.

Lloyd Davis; Jonathan Bunker

2011-01-01T23:59:59.000Z

302

Spectroscopic Studies of Atmospheric Relevant Air-Aqueous and Air-Silica DISSERTATION  

E-Print Network [OSTI]

process in the atmosphere. As models of these phenomena, interfacial water vapor uptake by #12;iii to the air-water interface were examined. Sum frequency generation (SFG), a surface specific techniqueSpectroscopic Studies of Atmospheric Relevant Air-Aqueous and Air-Silica Interfaces DISSERTATION

303

About Nuccio Heating & Air Headquartered in Tampa, Florida, Nuccio Heating & Air serves  

E-Print Network [OSTI]

­ the majority being highly mobile ­ sell and service heating and air conditioning systems for the company customer service Industry Focus Heating and air conditioning services Size 52 employees Case Study Nuccio Fixing Problems Fast In Florida's competitive air conditioning industry, the differentiator is "speed

Fisher, Kathleen

304

Indoor Air Quality Poor indoor air quality comes from many sources. It can lead to having  

E-Print Network [OSTI]

Indoor Air Quality Fact Sheet Poor indoor air quality comes from many sources. It can lead Indoor Air Pollutants · Molds · Pollen · Dander from pet fur · Secondhand smoke · Formaldehyde · Carbon monoxide that comes from burning propane, other gases and fuels, and charcoal · Household products

305

AirCloud: a cloud-based air-quality monitoring system for everyone  

Science Journals Connector (OSTI)

We present the design, implementation, and evaluation of AirCloud -- a novel client-cloud system for pervasive and personal air-quality monitoring at low cost. At the frontend, we create two types of Internet-connected particulate matter (PM2:5) ... Keywords: PM2.5, air quality, client-cloud calibration system

Yun Cheng, Xiucheng Li, Zhijun Li, Shouxu Jiang, Yilong Li, Ji Jia, Xiaofan Jiang

2014-11-01T23:59:59.000Z

306

1: Air Embolism Condi on: Suspected air embolism (decreased end-dal CO2  

E-Print Network [OSTI]

#12;1: Air Embolism Condi on: Suspected air embolism (decreased end- dal CO2 and oxygen satura on compression considered If head or cranial case? · Transesophageal echocardiography called for (if available? · Vasopressors (e.g. dobutamine, norepinephrine)? · Chest compressions (100/min; to force air through lock, even

Klemmer, Scott

307

inAir: A Longitudinal study of Indoor Air Quality Measurements and Visualizations  

E-Print Network [OSTI]

pollutants are colorless and odorless, while many activities are inconspicuous and routine. We implemented inAir. Among those, air pollution and its effects on health have been researched extensively over past several decades [13]. In particular, the health effects of air pollution cover a wide variety of respiratory

Mankoff, Jennifer

308

Improved Algal Harvesting Using Suspended Air Flotation  

E-Print Network [OSTI]

, consisting primarily of Chlorella and Scenedesmus, composed approximately 80% of the solids inventory during. Furthermore, use of SAF to harvest commercially grown Chlorella and Scenedesmus may reduce manufacturing costs). KEYWORDS: Suspended air flotation (SAF), dissolved air flotation (DAF), wastewater, algae, Chlorella

Jacobson, Arne

309

A laboratory air-supply system  

Science Journals Connector (OSTI)

A practical air-supply system is described for laboratory apparatus such as air tracks and tables using regenerative blower technology. This flexible system is easily constructed and is comparable in cost to commercially available systems. Its advantages include low noise high reliability and low maintenance.

1998-01-01T23:59:59.000Z

310

U.S.Air Force Advanced Power  

E-Print Network [OSTI]

efficiency,improved power distribution,reduced fuel dependency,reduction of noise,heat,and visual signatureU.S.Air Force Advanced Power Technology Office (APTO) U.S.Air Force Advanced Power Technology/Wind Powered Hydrogen Generation for Fuel Cell Applications · Waste-To-Energy APTO/Small Business Innovation

311

Power Characteristics of Industrial Air Compressors  

E-Print Network [OSTI]

and with different loads are discussed as case studies. The case studies illustrate how to identify the type of control, and potential problems such as inadequate compressed air storage, over-sized compressors, and compressed air leaks from the power signatures...

Schmidt, C.; Kissock, K.

312

EPA expands air quality emissions trading policy  

Science Journals Connector (OSTI)

EPA expands air quality emissions trading policy ... The Environmental Protection Agency has expanded its old "bubble policy" into a wider-ranging, supposedly more effective, emissions trading program designed to speed up attainment of national air quality standards and save money. ... It also authorizes states to adopt generic emissions trading rules and extend these to all ... ...

1982-04-12T23:59:59.000Z

313

AT 560 (2 Credits) Air Pollution Measurement  

E-Print Network [OSTI]

AT 560 (2 Credits) Air Pollution Measurement Spring 2013 Instructor: Jeff Collett, 491 Resolution and Student Conduct Services." #12;ATS 560 - Air Pollution Measurement Spring 2013 Schedule Useful. 11, 13 Atmospheric Aero- sols/Sampling Lab #2: Aerosol and trace gas sampling; 5 Feb. 18, 20 Intro

314

central air conditioner | OpenEI  

Open Energy Info (EERE)

central air conditioner central air conditioner Dataset Summary Description View 2010 energy efficiency data from AeroSys Inc, Coaire, Cold Point, First Operations, LG Electronics, Nordyne, and Quietside manufacturers. Data includes cooling capacity, cooling performance, heating capacity, and heating performance. Spreadsheet was created by combining the tables in pdf files that are included in the zip file. Source Energy Applicance Data - United States Federal Trade Commission, www.ftc.gov Date Released Unknown Date Updated Unknown Keywords air conditioner central air conditioner efficiency efficient energy heat pump Data application/vnd.ms-excel icon 2010_CentralAC_All.xls (xls, 82.4 KiB) application/zip icon 2010CentralAirConditioner.zip (zip, 398.2 KiB) Quality Metrics Level of Review Some Review

315

average air temperature | OpenEI  

Open Energy Info (EERE)

average air temperature average air temperature Dataset Summary Description (Abstract): Air Temperature at 10 m Above The Surface Of The Earth (deg C)NASA Surface meteorology and Solar Energy (SSE) Release 6.0 Data Set (Nov 2007)22-year Monthly & Annual Average (July 1983 - June 2005)Parameter: Air Temperature at 10 m Above The Surface Of The Earth (deg C)Internet: http://eosweb.larc.nasa.gov/sse/Note 1: SSE Methodology & Accuracy sections onlineNote 2: Lat/Lon values indicate the lower left corner of a 1x1 degree region. Negative values are south and west; Source U.S. National Aeronautics and Space Administration (NASA), Surface meteorology and Solar Energy (SSE) Date Released March 31st, 2009 (5 years ago) Date Updated April 01st, 2009 (5 years ago) Keywords average air temperature

316

Air Pollution Control (Michigan) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Air Pollution Control (Michigan) Air Pollution Control (Michigan) Air Pollution Control (Michigan) < Back Eligibility Utility Fed. Government Commercial Agricultural Investor-Owned Utility State/Provincial Govt Industrial Construction Municipal/Public Utility Local Government Residential Installer/Contractor Rural Electric Cooperative Tribal Government Low-Income Residential Schools Retail Supplier Institutional Multi-Family Residential Systems Integrator Fuel Distributor Nonprofit General Public/Consumer Transportation Program Info State Michigan Program Type Environmental Regulations Siting and Permitting Provider Department of Environmental Quality This rule requires an annual report from a commercial, industrial, or governmental source of emission of an air contaminant if, in the judgment of the Department, information on the quantity and composition of an air

317

Air Quality: Implementation Plan Department: Chemical and General Safety  

E-Print Network [OSTI]

Air Quality: Implementation Plan Department: Chemical and General Safety Program: Air Quality Owner: Program Manager Authority: ES&H Manual, Chapter 30, Air Quality1 The requirements of Chapter 30, "Air in place 1 SLAC Environment, Safety, and Health Manual (SLAC-I-720-0A29Z-001), Chapter 30, "Air Quality

Wechsler, Risa H.

318

Parallelization of Air Quality Models on Structured Grids Using MPI  

E-Print Network [OSTI]

by the Clean Air Act in the United States. In order to understand air pollution and design e#11;ective control of the greatest concerns is air pollution. Air pollutants a#11;ect human health, the biosphere and damage property. Because of these e#11;ects air pollution is now monitored and regulated worldwide, for example

Sandu, Adrian

319

Air Quality: Acronym List Department: Chemical and General Safety  

E-Print Network [OSTI]

hazard analysis AQPM air quality program manager ARP accidental release prevention ATCM air toxic control Standard NESHAPs National Emissions Standards for Hazardous Air Pollutants NOx oxides of nitrogen NPOC nonAir Quality: Acronym List Department: Chemical and General Safety Program: Air Quality Owner

Wechsler, Risa H.

320

Simple Interactive Models for better air quality (SIM-air) | Open Energy  

Open Energy Info (EERE)

Simple Interactive Models for better air quality (SIM-air) Simple Interactive Models for better air quality (SIM-air) Jump to: navigation, search Tool Summary Name: Simple Interactive Models (SIM-air) Agency/Company /Organization: UrbanEmissions.info Sector: Climate, Energy User Interface: Desktop Application Complexity/Ease of Use: Moderate Website: urbanemissions.info/model-tools/sim-air.html Cost: Free Related Tools Tool for Selecting CDM Methods & Technologies ProForm Environmental Impact and Sustainability Applied General Equilibrium Model (ENVISAGE) ... further results Find Another Tool FIND DEVELOPMENT IMPACTS ASSESSMENT TOOLS A set of software-based integrated air pollution analysis tools that illustrate how cities in developing countries, despite the informational, institutional and infrastructural limitations they face, can begin to

Note: This page contains sample records for the topic "kafb kirtland air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Atmospheric CO2 From Flask Air Samples at 10 Sites in the SIO Air Sampling  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Flask Air Samples, SIO Network Flask Air Samples, SIO Network Atmospheric CO2 From Flask Air Samples at 10 Sites in the SIO Air Sampling Network Scripps Institution of Oceanography Monitoring Sites Scripps Institution of Oceanography Monitoring Sites Mauna Loa, Hawaii Mauna Loa weekly average CO2 concentrations derived from continuous air samples Barrow, Alaska American Samoa South Pole Daily average CO2 concentrations derived from continuous air samples Alert, NWT, Canada Cape Kumukahi Christmas Island Baring Head Kermadec Island La Jolla Pier La Jolla Pier weekly average CO2 concentrations derived from continuous air samples PDF Documentation available as Atmospheric Carbon Dioxide Concentrations at 10 Locations Spanning Latitudes 82°N to 90°S, (NDP-001a) For information on calibration and some additional literature, go to

322

Measurement of particulate densities in air  

Science Journals Connector (OSTI)

Clean air is one of the most important issues that govern the health of all live forms. However presently there are not many quick and simple methods for measuring impurities like particulates in air. These impurities have an enormous diversity in their physical and chemical structure. They may be unburned carbon particles from a diesel engine exhaust and chimney pollen grains in the spring air or asbestos in a factory. This paper shows that changes in the composition of the air cause a change in the speed of sound. Therefore by measuring the change in the speed of sound it is possible to monitor the density of particulates in the air. Preliminary tests are conducted on various smokeair mixtures. The results demonstrate that this methodology is very sensitive to any changes in the composition of the air. Its implementation is very simple and efficient and costs much less than the conventional method currently used in the auto industry. This technique will be used to calculate the mass density of the particulates resulting from a diesel engine and results thus obtained will be compared with those calculated using other methods.

2001-01-01T23:59:59.000Z

323

Ductless Mini-Split Air Conditioners | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Ductless Mini-Split Air Conditioners Ductless Mini-Split Air Conditioners Ductless Mini-Split Air Conditioners August 9, 2012 - 4:05pm Addthis A ductless mini-split air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/LUke1138. A ductless mini-split air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/LUke1138. What does this mean for me? A ductless mini-split air conditioner is easier to install than a central air conditioning system. A ductless mini-split air conditioner provides zoned air conditioning without ducting. A ductless mini-split air conditioner is relatively easy to install and does not provide an entry point for intruders as some room air conditioners do. Ductless, mini split-system air-conditioners (mini splits) have numerous

324

Determine the Cost of Compressed Air for Your Plant | Department...  

Broader source: Energy.gov (indexed) [DOE]

Determine the Cost of Compressed Air for Your Plant Determine the Cost of Compressed Air for Your Plant This tip sheet discusses a method for determining the cost of compressed air...

325

INDOOR AIR QUALITY MEASUREMENTS IN ENERGY EFFICIENT BUILDINGS  

E-Print Network [OSTI]

the effect of air pollution on human health, 2) the designgenerated indoor air pollution on human health; and if borneAir Pollution Control Association, Portland, Oregon (June 27-July 1, 1976). vJorld Health

Hollowell, C.D.

2011-01-01T23:59:59.000Z

326

Indoor Air Pollution and Its Control in China  

Science Journals Connector (OSTI)

The status of indoor air pollution and its control in China are reviewed by introducing the pollution characteristics of major indoor air pollutants, the strategies and measures adopted to control indoor air pollution

Jiming Hao; Tianle Zhu; Xing Fan

2014-01-01T23:59:59.000Z

327

Roswell International Air Center Airport (ROW) Pavement Condition and Analysis  

E-Print Network [OSTI]

Roswell International Air Center Airport (ROW) Pavement Condition and Analysis Submitted to: Jane M ................................................1. Conditions at Roswell International Air Center (ROW) 4 .................................Figure 1. Geographic Location of Roswell International Air Center (ROW) 4 ..............................Table 1

Cal, Mark P.

328

Flying Height Drop Due to Air Entrapment in Lubricant  

Science Journals Connector (OSTI)

Recently, it is found experimentally that the flying height of an air bearing slider is influenced by the lubricant on the disk. It is explained as the air molecules ... in air bearing force, and hence, the flying

Wei Hua; Kang Kee Ng; Shengkai Yu; Bo Liu; Vivian Ng

2013-10-01T23:59:59.000Z

329

INDOOR AIR QUALITY IN ENERGY-EFFICIENT BUILDINGS  

E-Print Network [OSTI]

for studies of indoor air quality and energy utilization inExt. 6782 Indoor Air Quality in Energy- Buildings Craig D.1, 1979) Indoor Air Quality in Energy~Efficient LBL-8892 EEB

Hollowell, Craig D.

2011-01-01T23:59:59.000Z

330

Cold Air Distribution in Office Buildings: Technology Assessment for California  

E-Print Network [OSTI]

1988. Cold Air Distribution Design Guide. EPRI Report EM-match the cold air distribution design, the floor-to-floorinclude cold air distribution in their designs. The projects

Bauman, F.S.

2008-01-01T23:59:59.000Z

331

Property:AirQualityPermitProcess | Open Energy Information  

Open Energy Info (EERE)

"AirQualityPermitProcess" Showing 1 page using this property. R RAPIDOverviewGeothermalAir QualityAlaska + The Air Permit process in Alaska is divided into two divisions: Title...

332

AUTOMATIC VARIABLE VENTILATION CONTROL SYSTEMS BASED ON AIR QUALITY DETECTION  

E-Print Network [OSTI]

Control Systems Based on Air Quality Detection Isaac Turiel,HVAC CONTROL SYSTEM BASED ON AIR QUALITY SENSING To Zl)(lecontrol systems based on air quality detection Isaac Turiel,

Turiel, Isaac

2011-01-01T23:59:59.000Z

333

Application of Coal Fly Ash in Air Quality Management  

Science Journals Connector (OSTI)

Application of Coal Fly Ash in Air Quality Management ... It has been found from the literature that fly ash possesses potential application in the management of air quality. ... Application of Zeolite Synthesized from Fly Ash in Air Quality Management ...

M. Ahmaruzzaman; V.K Gupta

2012-11-05T23:59:59.000Z

334

Indoor air quality program set up at EPA  

Science Journals Connector (OSTI)

The Environmental Protection Agency has just set up an indoor air quality program within the Office of Air & Radiation. Its charge is to coordinate EPA's effort to address the multitude of indoor air pollution problems and to distribute information on ...

LOIS EMBER

1987-07-20T23:59:59.000Z

335

Integrating Comprehensive Air Quality Modeling with Policy Analysis  

E-Print Network [OSTI]

Integrating Comprehensive Air Quality Modeling with Policy Analysis: Applications for Distributed Air Quality Modeling with Policy Analysis: Applications for Distributed Electricity Generation renewable technologies. These facilities also shift the magnitude, timing and location of air quality

336

MCA 75-2 - Air Quality | Open Energy Information  

Open Energy Info (EERE)

StatuteStatute: MCA 75-2 - Air QualityLegal Abstract Clean Air Act of Montana governs air pollution regulation. Published NA Year Signed or Took Effect 1997 Legal Citation...

337

UNITED STATES AIR FORCE OUTSIDE THE NATIONAL CAPITAL REGION  

E-Print Network [OSTI]

program in order to reduce Federal employee's contribution to traffic congestion and air pollutionUNITED STATES AIR FORCE OUTSIDE THE NATIONAL CAPITAL REGION PUBLIC TRANSPORTATION BENEFIT PROGRAM): ____________ City (Residence): __________________________State: _______________ Zip Code: ________________ Air Force

338

Ductless Mini-Split Air Conditioners | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Ductless Mini-Split Air Conditioners Ductless Mini-Split Air Conditioners Ductless Mini-Split Air Conditioners August 9, 2012 - 4:05pm Addthis A ductless mini-split air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/LUke1138. A ductless mini-split air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/LUke1138. What does this mean for me? A ductless mini-split air conditioner is easier to install than a central air conditioning system. A ductless mini-split air conditioner provides zoned air conditioning without ducting. A ductless mini-split air conditioner is relatively easy to install and does not provide an entry point for intruders as some room air conditioners do. Ductless, mini split-system air-conditioners (mini splits) have numerous

339

Measuring air pollution using a mobile, bicycle-based platform  

E-Print Network [OSTI]

Measuring air pollution using a mobile, bicycle-based platform Steve Hankey University-walkability Physical activity Air pollution 2 #12;Approach: Mobile, bicycle-based sampling Air pollution measurements

Minnesota, University of

340

Air Barriers for Residential and Commercial Buildings  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Air Barriers for Residential and Air Barriers for Residential and Commercial Buildings Diana Hun, PhD Oak Ridge National Laboratory dehun@ornl.gov 865-574-5139 April 4, 2013 BTO Program Peer Review 2 | Building Technologies Office eere.energy.gov Problem Statement & Project Focus - Air leakage is a significant contributor to HVAC loads - ~50% in residential buildings (Sherman and Matson 1997) - ~33% of heating loads in office buildings (Emmerich et al. 2005) - Airtightness of buildings listed in BTO prioritization tool

Note: This page contains sample records for the topic "kafb kirtland air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Air blast type coal slurry fuel injector  

DOE Patents [OSTI]

A device to atomize and inject a coal slurry in the combustion chamber of an internal combustion engine, and which eliminates the use of a conventional fuel injection pump/nozzle. The injector involves the use of compressed air to atomize and inject the coal slurry and like fuels. In one embodiment, the breaking and atomization of the fuel is achieved with the help of perforated discs and compressed air. In another embodiment, a cone shaped aspirator is used to achieve the breaking and atomization of the fuel. The compressed air protects critical bearing areas of the injector.

Phatak, Ramkrishna G. (San Antonio, TX)

1986-01-01T23:59:59.000Z

342

Chapter 4 - Air Pollution Decision Tools  

Science Journals Connector (OSTI)

Abstract Different types of information must be evaluated and integrated to support means of addressing air pollution. Evidence-based is compared to precaution-based air pollution risk assessment. The entire spectrum of risk-based decision making is considered, including risk perception. Air pollution statistics and probability are discussed using examples and case studies, including radon, black swan events, toxic clouds such as the one in Bhopal, India and explosions and fires such as the one caused by the derailment in Lac-Mgantic in eastern Quebec, Canada.

Daniel Vallero

2014-01-01T23:59:59.000Z

343

Air Barriers for Residential and Commercial Buildings  

Broader source: Energy.gov (indexed) [DOE]

Air Barriers for Residential and Air Barriers for Residential and Commercial Buildings Diana Hun, PhD Oak Ridge National Laboratory dehun@ornl.gov 865-574-5139 April 4, 2013 BTO Program Peer Review 2 | Building Technologies Office eere.energy.gov Problem Statement & Project Focus - Air leakage is a significant contributor to HVAC loads - ~50% in residential buildings (Sherman and Matson 1997) - ~33% of heating loads in office buildings (Emmerich et al. 2005) - Airtightness of buildings listed in BTO prioritization tool

344

E-Print Network 3.0 - ambient air quality-a Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

EHHE; January 2006 7 Topics Air, Ambient (Outdoor) Air, Indoor Disasters Lead... pollutants in ambient air Hazardous or toxic substances released in ambient air Residence in...

345

E-Print Network 3.0 - ambient air monitoring Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

EHHE; January 2006 7 Topics Air, Ambient (Outdoor) Air, Indoor Disasters Lead... pollutants in ambient air Hazardous or toxic substances released in ambient air Residence in...

346

BUILDING VENTILATION AND INDOOR AIR QUALITY PROGRAM. CHAPTER FROM ENERGY AND ENVIRONMENT DIVISION ANNUAL REPORT 1978  

E-Print Network [OSTI]

Yocum, "A Study of Indoor Air Quality," ~_Air Pollut. Contr.discusses the Indoor Air Quality research supported by theAssociation, "Community Air Quality Guides, Aldehydes," Am.

Cairns, Elton J.

2011-01-01T23:59:59.000Z

347

E-Print Network 3.0 - air quality levels Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

A Breath of Fresh Air: Improving Air Summary: about unhealthful levels of air pollution. Impact Air quality forecasts and warnings for health... Learn More:...

348

A study of air flow through saturated porous media and its applications to in-situ air sparging  

E-Print Network [OSTI]

The efficiency of an in situ air sparging system is controlled by the extent of contact between injected air and contaminated soil and pore fluid. Characterizing the mechanisms governing air propagation through saturated ...

Marulanda, Catalina, 1971-

2001-01-01T23:59:59.000Z

349

Quantifying the Air Pollution Exposure Consequences of Distributed Electricity Generation  

E-Print Network [OSTI]

species) control technology criteria pollutant air pollutantControl Cogen Urban Santa Maria Elevated Data sources: Emissions: 1999 National Emissions Inventory for Hazardous Air Pollutants (

Heath, Garvin A.; Granvold, Patrick W.; Hoats, Abigail S.; Nazaroff, William W

2005-01-01T23:59:59.000Z

350

New Air Cleaning Strategies for Reduced Commercial Building Ventilation Energy  

E-Print Network [OSTI]

1) indoor pollutant source control, and 2) air cleaning.control is complicated by the large number and changing nature of indoor pollutant sources. Particle air

Sidheswaran, Meera

2010-01-01T23:59:59.000Z

351

Possible molecular mechanisms linking air pollution and asthma in children  

Science Journals Connector (OSTI)

Air pollution has many effects on the health of ... is to discuss the possible molecular mechanisms linking air pollution and asthma in children, also taking into...

Susanna Esposito; Rossana Tenconi; Mara Lelii; Valentina Preti

2014-03-01T23:59:59.000Z

352

Natural Gas Heat Pump and Air Conditioner | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Natural Gas Heat Pump and Air Conditioner Natural Gas Heat Pump and Air Conditioner Lead Performer: Thermolift - Stony Brook, NY Partners: -- New York State Energy Research &...

353

Shale Gas Development Challenges: Air | Department of Energy  

Office of Environmental Management (EM)

Challenges: Air Shale Gas Development Challenges: Air More Documents & Publications Natural Gas from Shale: Questions and Answers Challenges associated with shale gas...

354

Case Study: Evaluating Liquid versus Air Cooling in the Maui...  

Broader source: Energy.gov (indexed) [DOE]

Case Study: Evaluating Liquid versus Air Cooling in the Maui High Performance Computing Center Case Study: Evaluating Liquid versus Air Cooling in the Maui High Performance...

355

13-Energy Efficiency Ratio Window Air Conditioner | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Window Air Conditioner 13-Energy Efficiency Ratio Window Air Conditioner Lead Performer: Oak Ridge National Laboratory - Oak Ridge, TN Partners: General Electric - Fairfield, CT...

356

Webinar: Ventilation and Filtration Strategies with Indoor airPLUS...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Ventilation and Filtration Strategies with Indoor airPLUS and Zero Energy Ready Homes Webinar: Ventilation and Filtration Strategies with Indoor airPLUS and Zero Energy...

357

Hierarchically Porous Graphene as a Lithium-Air Battery Electrode...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Hierarchically Porous Graphene as a Lithium-Air Battery Electrode. Hierarchically Porous Graphene as a Lithium-Air Battery Electrode. Abstract: Functionalized graphene sheets (FGS)...

358

Commercial Air Conditioners and Heat Pumps | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Air Conditioners and Heat Pumps Commercial Air Conditioners and Heat Pumps commercialcacandhpv1.0.xlsx More Documents & Publications Residential Clothes Washers (Appendix J2)...

359

STATEMENT OF CONSIDERATIONS REQUEST BY AIR PRODUCTS AND CHEMICALS...  

Broader source: Energy.gov (indexed) [DOE]

in the attached waiver petition and in subsequent discussions with DOE Patent Counsel, Air Products and Chemicals, Inc. (Air Products) has requested an advance waiver of...

360

High-Temperature, Air-Cooled Traction Drive Inverter Packaging...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Temperature, Air-Cooled Traction Drive Inverter Packaging High-Temperature, Air-Cooled Traction Drive Inverter Packaging 2010 DOE Vehicle Technologies and Hydrogen Programs Annual...

Note: This page contains sample records for the topic "kafb kirtland air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Air Cooling Technology for Advanced Power Electronics and Electric...  

Broader source: Energy.gov (indexed) [DOE]

Air Cooling Technology for Advanced Power Electronics and Electric Machines Air Cooling Technology for Advanced Power Electronics and Electric Machines 2009 DOE Hydrogen Program...

362

Fact Sheet - Air Quality Permitting | Open Energy Information  

Open Energy Info (EERE)

Air Quality Permitting Jump to: navigation, search OpenEI Reference LibraryAdd to library PermittingRegulatory Guidance - GuideHandbook: Fact Sheet - Air Quality...

363

U.S. Air Force Energy Program Presentation  

Broader source: Energy.gov [DOE]

Omar Mendoza, U.S. Air Force, presentation on the U.S. Air Force Energy Program at the Advanced Biofuels Industry Roundtable.

364

Arene Trifluoromethylation: An Effective Strategy to Obtain Air...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Effective Strategy to Obtain Air-Stable nType Organic Semiconductors with Tunable Optoelectronic Arene Trifluoromethylation: An Effective Strategy to Obtain Air-Stable nType...

365

Air Cooling Technology for Power Electronic Thermal Control  

Broader source: Energy.gov (indexed) [DOE]

between model and test results * Developed innovative air-cooled heat sink concept - Heat transfer area doubled - Pressure loss decreased by 50% - Colder air directed to...

366

Advanced Variable Speed Air-Source Integrated Heat Pump 2013...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Advanced Variable Speed Air-Source Integrated Heat Pump 2013 Peer Review Advanced Variable Speed Air-Source Integrated Heat Pump 2013 Peer Review Emerging Technologies Project for...

367

Property:AirQualityPermitAgency | Open Energy Information  

Open Energy Info (EERE)

"AirQualityPermitAgency" Showing 1 page using this property. R RAPIDOverviewGeothermalAir QualityAlaska + Alaska Department of Environmental Conservation + Retrieved from...

368

Air Permit Program Information Page | Open Energy Information  

Open Energy Info (EERE)

Web Site: Air Permit Program Information Page Author Division of Air Quality Published Publisher Not Provided, Date Not Provided DOI Not Provided Check for DOI availability: http:...

369

Air Permit Program Application Forms | Open Energy Information  

Open Energy Info (EERE)

Web Site: Air Permit Program Application Forms Author Division of Air Quality Published Publisher Not Provided, Date Not Provided DOI Not Provided Check for DOI availability:...

370

Commonwealth of Virginia, State Air Pollution Control Board,...  

Broader source: Energy.gov (indexed) [DOE]

Commonwealth of Virginia, State Air Pollution Control Board, Order by Concent Issued to Mirant Potomac River, LLC, Registration No. 70228 Commonwealth of Virginia, State Air...

371

Colorado Construction Air Permit Application | Open Energy Information  

Open Energy Info (EERE)

for a construction permit for construction of a commercial or industrial source of air pollution. Form Type ApplicationNotice Form Topic Air Pollution Control Division -...

372

Knowledge Partnership for Measuring Air Pollution and Greenhouse...  

Open Energy Info (EERE)

Measuring Air Pollution and Greenhouse Gas Emissions in Asia Jump to: navigation, search Name Knowledge Partnership for Measuring Air Pollution and Greenhouse Gas Emissions in Asia...

373

Hawaii Air Pollution Control Permits Webpage | Open Energy Information  

Open Energy Info (EERE)

Jump to: navigation, search OpenEI Reference LibraryAdd to library Web Site: Hawaii Air Pollution Control Permits Webpage Abstract Information about Air Pollution Control...

374

Harboring Pollution: Air Quality Impacts of Marine Ports | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Harboring Pollution: Air Quality Impacts of Marine Ports Harboring Pollution: Air Quality Impacts of Marine Ports 2004 Diesel Engine Emissions Reduction (DEER) Conference...

375

Heat transfer pathways in underfloor air distribution (UFAD) systems  

E-Print Network [OSTI]

improving control of supply air temperature. This benefitloss of control of the supply air temperature from thecontrols to a constant plenum inlet temperature, thereby producing a supply temperature

Bauman, F.; Jin, H.; Webster, T.

2006-01-01T23:59:59.000Z

376

Design, modelling and control of a gas turbine air compressor .  

E-Print Network [OSTI]

??The production of compressed air constitutes a considerable portion of industrial electrical consumption. An alternative to electrically driven air compression systems is a gas turbine (more)

WIESE, ASHLEY PETER

2014-01-01T23:59:59.000Z

377

Alternative Fuels Data Center: Air Quality Improvement Program Funding -  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Air Quality Air Quality Improvement Program Funding - Ventura County to someone by E-mail Share Alternative Fuels Data Center: Air Quality Improvement Program Funding - Ventura County on Facebook Tweet about Alternative Fuels Data Center: Air Quality Improvement Program Funding - Ventura County on Twitter Bookmark Alternative Fuels Data Center: Air Quality Improvement Program Funding - Ventura County on Google Bookmark Alternative Fuels Data Center: Air Quality Improvement Program Funding - Ventura County on Delicious Rank Alternative Fuels Data Center: Air Quality Improvement Program Funding - Ventura County on Digg Find More places to share Alternative Fuels Data Center: Air Quality Improvement Program Funding - Ventura County on AddThis.com... More in this section...

378

Imaging Lithium Air Electrodes | ornl.gov  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Neutron Imaging Reveals Lithium Distribution in Lithium-Air Electrodes Neutron Imaging Reveals Lithium Distribution in Lithium-Air Electrodes Agatha Bardoel - January 01, 2013 Image produced by neutron-computed tomography. The next step in revolutionizing electric vehicle capacity Research Contacts: Hassina Bilheux, Jagjit Nanda, and S. Pannala Using neutron-computed tomography, researchers at the CG-1D neutron imaging instrument at Oak Ridge National Laboratory's High Flux Isotope Reactor (HFIR) have successfully mapped the three-dimensional spatial distribution of lithium products in electrochemically discharged lithium-air cathodes. Lithium-air chemistry promises very high-energy density that, if successful, would revolutionize the world of electric vehicles by extending their range to 500 miles or more. The high-energy density comes from

379

Kirland Air Force Base wins Robot Rodeo  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Kirland Air Force Base wins Robot Rodeo Kirland Air Force Base wins Robot Rodeo Community Connections: Our link to Northern New Mexico Communities Latest Issue:Dec. 2013 - Jan. 2014 All Issues » submit Kirland Air Force Base wins Robot Rodeo Hazardous devices teams test their maneuvering skills July 1, 2013 Students from Valarde Middle School won the video competition in the Best in Show and Middle School categories. They are shown here with sixth-grade teacher Jimmy Lara. During the Robot Rodeo, an unseen operator attempts to conduct reconnaissance and rescue injured personnel Contact Editor Linda Anderman Email Community Programs Office Kurt Steinhaus Email Kirland Air Force Base wins Robot Rodeo Police and public safety teams from as far away as New Jersey recently convened in Albuquerque to test their ability to remotely deploy robots

380

DOE Investigates Possible Air Conditioner Efficiency Violations |  

Broader source: Energy.gov (indexed) [DOE]

Investigates Possible Air Conditioner Efficiency Violations Investigates Possible Air Conditioner Efficiency Violations DOE Investigates Possible Air Conditioner Efficiency Violations February 15, 2012 - 5:13pm Addthis The Department of Energy's Office of Enforcement is committed to its compliance enforcement responsibilities with regard to federal energy conservation standards and ensuring that all those subject to the requirements are treated fairly and equally. Today, the Office of Enforcement issued a series of subpoenas as part of an investigation to determine whether manufacturers of split-system air conditioners are making and distributing in the U.S. condensing units that do not meet the current 13 SEER (Seasonal Energy Efficiency Ratio) federal energy conservation standard, which has been the standard since 2006.

Note: This page contains sample records for the topic "kafb kirtland air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Capture of carbon dioxide from ambient air  

Science Journals Connector (OSTI)

Carbon dioxide capture from ambient air could compensate for all carbon dioxide emissions to the atmosphere. Such capture would, for example, make it possible to use liquid, carbon-based fuels in cars or airplane...

K.S. Lackner

2009-09-01T23:59:59.000Z

382

Metabolon Catalyzed Pyruvate/Air Biofuel Cell  

Science Journals Connector (OSTI)

Metabolon Catalyzed Pyruvate/Air Biofuel Cell ... Simpler Is Better: High-Yield and Potential Low-Cost Biofuels Production through Cell-Free Synthetic Pathway Biotransformation (SyPaB) ...

Michael J. Moehlenbrock; Timothy K. Toby; Abdul Waheed; Shelley D. Minteer

2010-04-20T23:59:59.000Z

383

U.S. Air Force UESCs  

Broader source: Energy.gov [DOE]

Presentationgiven at the Spring 2009 Federal Utility Partnership Working Group (FUPWG) meetingcovers the U.S. Air Force's approval process, submittal requirements, and guidelines for utility energy service contracts (UESCs).

384

Understanding the Basics of Compressed Air Systems  

E-Print Network [OSTI]

, contaminated filters, conversion to electrically operated hoists, and the use of centrifugal fans or compressed air with pressure regulators to purge control cabinets. Finally, a review of compressor technologies with typical cfm, pressure ranges, and price...

Herron, D. J.

385

Large panel design for containment air baffle  

DOE Patents [OSTI]

The movable air baffle shield means in accordance with the present invention provides an efficient method of cooling the space surrounding the containment vessel while also providing the capability of being moved away from the containment vessel during inspection. The containment apparatus comprises a generally cylindrical sealed containment vessel for containing at least a portion of a nuclear power generation plant, a disparate shield building surrounding and housing the containment vessel therein and spaced outwardly thereof so as to form an air annulus in the space between the shield building and the containment vessel, a shield baffle means positioned in the air annulus around at least a portion of the sides of the containment vessel providing a coolant path between the baffle means and the containment vessel to permit cooling of the containment vessel by air, the shield baffle means being movable to afford access to the containment vessel.

Orr, Richard S. (Pittsburgh, PA)

1992-01-01T23:59:59.000Z

386

Iron-air battery development program  

SciTech Connect (OSTI)

The progress and status of the research and development program on the iron-air advanced technology battery system at the Westinghouse Electric Corporation during the period June 1978-December 1979 are described. This advanced battery system is being developed for electric vehicle propulsion applications. Testing and evaluation of 100 cm/sup 2/ size cells was undertaken while individual iron and air electrode programs continued. Progress is reported in a number of these study areas. Results of the improvements made in the utilization of the iron electrode active material coupled with manufacturing and processing studies related to improved air electrodes continue to indicate that a fully developed iron-air battery system will be capable of fulfilling the performance requirements for commuter electric vehicles.

Buzzelli, E.S.; Liu, C.T.; Bryant, W.A.

1980-05-01T23:59:59.000Z

387

Covered Product Category: Residential Central Air Conditioners...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

operate on single-phase current and have cooling capacities less than 65,000 Btuh. Room air conditioners (window and through-the-wall) are covered by a separate specification,...

388

Geothermal Power Plants Meeting Clean Air Standards  

Broader source: Energy.gov [DOE]

Geothermal power plants can meet the most stringent clean air standards. They emit little carbon dioxide, very low amounts of sulfur dioxide, and no nitrogen oxides. See Charts 1, 2, and 3 below.

389

Air Conditioning Heating and Refrigeration Institute Comment  

Broader source: Energy.gov [DOE]

These comments are submitted by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) in response to the U.S. Department of Energys (DOE) notice in the July 3, 2014 Federal Register...

390

Air separation with temperature and pressure swing  

DOE Patents [OSTI]

A chemical absorbent air separation process is set forth which uses a temperature swing absorption-desorption cycle in combination with a pressure swing wherein the pressure is elevated in the desorption stage of the process.

Cassano, Anthony A. (Allentown, PA)

1986-01-01T23:59:59.000Z

391

A transient-flow syringe air permeameter  

E-Print Network [OSTI]

In response to the need to better describe spatial variations in permeability, we designed and built a new portable field air permeameter for use on rocks in outcrop and core. In this instrument, a chamber containing a ...

Brown, Stephen

392

COMBUSTION-GENERATED INDOOR AIR POLLUTION  

E-Print Network [OSTI]

standard I[ o Fig. 2. Nitrogen dioxide concentrations in aCritical Analysis of Nitrogen Dioxide Air Quality Standards,with gas appliances. Nitrogen dioxide levels in kitchens of

Hollowell, C.D.

2011-01-01T23:59:59.000Z

393

Air Pollution Issues of the 1990's  

E-Print Network [OSTI]

Congress is currently debating various options for a new clean air bill. Whatever the outcome, significant social and economic changes are sure to result. Texas will be affected to one degree or another. These effects must be considered...

Myers, J. C.

394

High-energy metal air batteries  

DOE Patents [OSTI]

Disclosed herein are embodiments of lithium/air batteries and methods of making and using the same. Certain embodiments are pouch-cell batteries encased within an oxygen-permeable membrane packaging material that is less than 2% of the total battery weight. Some embodiments include a hybrid air electrode comprising carbon and an ion insertion material, wherein the mass ratio of ion insertion material to carbon is 0.2 to 0.8. The air electrode may include hydrophobic, porous fibers. In particular embodiments, the air electrode is soaked with an electrolyte comprising one or more solvents including dimethyl ether, and the dimethyl ether subsequently is evacuated from the soaked electrode. In other embodiments, the electrolyte comprises 10-20% crown ether by weight.

Zhang, Ji-Guang; Xiao, Jie; Xu, Wu; Wang, Deyu; Williford, Ralph E.; Liu, Jun

2014-07-01T23:59:59.000Z

395

High-energy metal air batteries  

DOE Patents [OSTI]

Disclosed herein are embodiments of lithium/air batteries and methods of making and using the same. Certain embodiments are pouch-cell batteries encased within an oxygen-permeable membrane packaging material that is less than 2% of the total battery weight. Some embodiments include a hybrid air electrode comprising carbon and an ion insertion material, wherein the mass ratio of ion insertion material to carbon is 0.2 to 0.8. The air electrode may include hydrophobic, porous fibers. In particular embodiments, the air electrode is soaked with an electrolyte comprising one or more solvents including dimethyl ether, and the dimethyl ether subsequently is evacuated from the soaked electrode. In other embodiments, the electrolyte comprises 10-20% crown ether by weight.

Zhang, Ji-Guang; Xiao, Jie; Xu, Wu; Wang, Deyu; Williford, Ralph E.; Liu, Jun

2013-07-09T23:59:59.000Z

396

Compressed Air Load Reduction Approaches and Innovations  

E-Print Network [OSTI]

are assessed. It is a common practice in facilities to simply add compressor capacity when faced with supply pressure or volume deficiencies, increasing the energy consumption associated with compressed air systems in industry. Additionally, in recent years...

D'Antonio, M.; Epstein, G.; Moray, S.; Schmidt, C.

2005-01-01T23:59:59.000Z

397

Operation & Maintenance for Quality Indoor Air  

E-Print Network [OSTI]

The results of numerous Indoor Air Quality (IAQ) building investigations conducted by the Georgia Tech Research Institute have shown that building Operation and Maintenance (O&M) is a very common source of IAQ problems. This paper presents...

Downing, C.; Bayer, C. W.

1990-01-01T23:59:59.000Z

398

Economizer Control Using Mixed Air Enthalpy  

E-Print Network [OSTI]

Enthalpy economizer can theoretically save more energy than temperature based economizer. However, the requirement of outdoor air humidity measurement in the traditional enthalpy economizer control made it impossible. A novel control sequence using...

Feng, J.; Liu, M.; Pang, W.

2007-01-01T23:59:59.000Z

399

Khalil Amine on Lithium-air Batteries  

ScienceCinema (OSTI)

Khalil Amine, materials scientist at Argonne National Laboratory, speaks on the new technology Lithium-air batteries, which could potentially increase energy density by 5-10 times over lithium-ion batteries.

Khalil Amine

2010-01-08T23:59:59.000Z

400

Fungal Fragments as Indoor Air Biocontaminants  

Science Journals Connector (OSTI)

...of ELISA MicroWell plates (Nalge Nunc International, Naperville, Ill.) and were incubated...Seppanen (ed.), Particles, microbes, radon, vol. 4. Proceedings of Indoor Air...problems in the Netherlands: a pilot project to solve problem in social housing...

Rafa? L. Grny; Tiina Reponen; Klaus Willeke; Detlef Schmechel; Enric Robine; Marjorie Boissier; Sergey A. Grinshpun

2002-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "kafb kirtland air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Improving Air Quality with Solar Energy  

SciTech Connect (OSTI)

This fact sheet series highlights how renewable energy and energy efficiency technologies can and are being used to reduce air emissions and meet environmental goals, showcasing case studies and technology-specific topics. This one focus on solar energy technologies.

Not Available

2008-04-01T23:59:59.000Z

402

Health Damages from Air Pollution in China  

E-Print Network [OSTI]

In China, elevated levels of urban air pollution result in substantial adverse health impacts for its large and rapidly growing urban population. An expanded version of the Emissions Prediction and Policy Analysis (EPPA), ...

Matus, Kira

403

Training: Compressed Air Systems | Department of Energy  

Energy Savers [EERE]

of Compressed Air Systems - 1-day workshop Availability: Onsite instructor-led and web edition (four, two-hour, live webinars make up the web edition training) Find out how a...

404

Improving Air Quality with Solar Energy  

DOE R&D Accomplishments [OSTI]

This fact sheet series highlights how renewable energy and energy efficiency technologies can and are being used to reduce air emissions and meet environmental goals, showcasing case studies and technology-specific topics. This one focus on solar energy technologies.

2008-04-00T23:59:59.000Z

405

Alternatives to Electric Air Conditioning Systems  

E-Print Network [OSTI]

The rapid escalation of electricity prices has created an opportunity to re-introduce gas-fired air conditioning systems to the commercial building market. In 1985 Gas Research Institute initiated a program to develop an advanced gas engine...

Lindsay, B. B.; Koplow, M. D.

1988-01-01T23:59:59.000Z

406

Changing patterns of air conditioning in Japan  

Science Journals Connector (OSTI)

Japanese air conditioning patterns have changed significantly over the past 30 years. The changes can be linked to increasing affluence and the consequent changes Japanese life patterns, but also to changes in...

Harold Wilhite; Hidetoshi Nakagami

1999-01-01T23:59:59.000Z

407

Sponsored by Air Force Research Laboratory  

E-Print Network [OSTI]

Sponsored by Air Force Research Laboratory Space Vehicles Directorate Directed Energy Directorate PROGRAM Space Scholars and Directed Energy Scholars The Space Vehicles and Directed Energy Directorates Scholars The Phillips Scholars internship offers an edu- cational and fulfilling summer job experience

Piao, Daqing

408

Effects of Air Pollution Control on Climate  

E-Print Network [OSTI]

Urban air pollution and climate are closely connected due to shared generating processes (e.g., combustion) for emissions of the driving gases and aerosols. They are also connected because the atmospheric lifecycles of ...

Prinn, Ronald G.

409

ARM - Campaign Instrument - irt-air  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

us a note below or call us at 1-888-ARM-DATA. Send Campaign Instrument : Infrared Thermometer - Airborne (IRT-AIR) Instrument Categories Radiometric Campaigns 1999 Northeast...

410

Dehumidification and cooling loads from ventilation air  

SciTech Connect (OSTI)

The importance of controlling humidity in buildings is cause for concern, in part, because of indoor air quality problems associated with excess moisture in air-conditioning systems. But more universally, the need for ventilation air has forced HVAC equipment (originally optimized for high efficiency in removing sensible heat loads) to remove high moisture loads. To assist cooling equipment and meet the challenge of larger ventilation loads, several technologies have succeeded in commercial buildings. Newer technologies such as subcool/reheat and heat pipe reheat show promise. These increase latent capacity of cooling-based systems by reducing their sensible capacity. Also, desiccant wheels have traditionally provided deeper-drying capacity by using thermal energy in place of electrical power to remove the latent load. Regardless of what mix of technologies is best for a particular application, there is a need for a more effective way of thinking about the cooling loads created by ventilation air. It is clear from the literature that all-too-frequently, HVAC systems do not perform well unless the ventilation air loads have been effectively addressed at the original design stage. This article proposes an engineering shorthand, an annual load index for ventilation air. This index will aid in the complex process of improving the ability of HVAC systems to deal efficiently with the amount of fresh air the industry has deemed useful for maintaining comfort in buildings. Examination of typical behavior of weather shows that latent loads usually exceed sensible loads in ventilation air by at least 3:1 and often as much as 8:1. A designer can use the engineering shorthand indexes presented to quickly assess the importance of this fact for a given system design. To size those components after they are selected, the designer can refer to Chapter 24 of the 1997 ASHRAE Handbook--Fundamentals, which includes separate values for peak moisture and peak temperature.

Harriman, L.G. III [Mason-Grant, Portsmouth, NH (United States); Plager, D. [Quantitative Decision Support, Portsmouth, NH (United States); Kosar, D. [Gas Research Inst., Chicago, IL (United States)

1997-11-01T23:59:59.000Z

411

Hanford Site air operating permit application  

SciTech Connect (OSTI)

The Clean Air Act Amendments of 1990, which amended the Federal Clean Air Act of 1977, required that the US Environmental Protection Agency develop a national Air Operating Permit Program, which in turn would require each state to develop an Air Operating Permit Program to identify all sources of ``regulated`` pollutants. Regulated pollutants include ``criteria`` pollutants (oxides of nitrogen, sulfur oxides, total suspended particulates, carbon monoxide, particulate matter greater than 10 micron, lead) plus 189 other ``Hazardous`` Air Pollutants. The Hanford Site, owned by the US Government and operated by the US Department of Energy, Richland Operations Office, is located in southcentral Washington State and covers 560 square miles of semi-arid shrub and grasslands located just north of the confluence of the Snake and Yakima Rivers with the Columbia River. This land, with restricted public access, provides a buffer for the smaller areas historically used for the production of nuclear materials, waste storage, and waste disposal. About 6 percent of the land area has been disturbed and is actively used. The Hanford Site Air Operating Permit Application consists of more than 1,100 sources and in excess of 300 emission points. Before January 1995, the maintenance and operations contractor and the environmental restoration contractor for the US Department of Energy completed an air emission inventory on the Hanford Site. The inventory has been entered into a database so that the sources and emission points can be tracked and updated information readily can be retrieved. The Hanford Site Air Operating Permit Application contains information current as of April 19, 1995.

NONE

1995-05-01T23:59:59.000Z

412

Air Activation Following an Atmospheric Explosion  

SciTech Connect (OSTI)

In addition to thermal radiation and fission products, nuclear explosions result in a very high flux of unfissioned neutrons. Within an atmospheric nuclear explosion, these neutrons can activate the various elemental components of natural air, potentially adding to the radioactive signature of the event as a whole. The goal of this work is to make an order-of-magnitude estimate of the total amount of air activation products that can result from an atmospheric nuclear explosion.

Lowrey, Justin D.; McIntyre, Justin I.; Prichard, Andrew W.; Gesh, Christopher J.

2013-03-13T23:59:59.000Z

413

Phenomenology of cosmic ray air showers  

E-Print Network [OSTI]

The properties of cosmic rays with energies above 1PeV have to be deduced from the spacetime structure and particle content of the air showers which they initiate. In this review, a summary of the phenomenology of these giant air showers is presented. We describe the hadronic interaction models used to extrapolate results from collider data to ultra high energies, an also the main electromagnetic processes that govern the longitudinal shower evolution as well as the lateral spread of particles.

M. T. Dova

2005-05-30T23:59:59.000Z

414

Compressed Air Systems Audits - Why? And How?  

E-Print Network [OSTI]

% of the compressed air costs, most with little or no capital investment. Almost always, in the event of a capital outlay, energy savings alone afford less than one-year payback. Many energy utility companies energetically support these efforts, and some.... Secondly, join us in the definition of compressed air as a system, the totality of which is comprised of the Supply Side and the Demand Side. The Supply Side is the compressors and their controls, receivers (primary storage tanks), aftercoolers, filters...

Kemp, H. L.

2004-01-01T23:59:59.000Z

415

Air Emission Regulations for the Prevention, Abatement, and Control of Air  

Broader source: Energy.gov (indexed) [DOE]

Air Emission Regulations for the Prevention, Abatement, and Control Air Emission Regulations for the Prevention, Abatement, and Control of Air Contaminants (Mississippi) Air Emission Regulations for the Prevention, Abatement, and Control of Air Contaminants (Mississippi) < Back Eligibility Agricultural Commercial Construction Developer Fed. Government Fuel Distributor General Public/Consumer Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Low-Income Residential Multi-Family Residential Municipal/Public Utility Nonprofit Residential Retail Supplier Rural Electric Cooperative Schools State/Provincial Govt Systems Integrator Transportation Tribal Government Utility Program Info State Mississippi Program Type Environmental Regulations Siting and Permitting Provider Department of Environmental Quality The Air Emission Regulation for the Prevention, Abatement and Control of

416

EML Surface Air Sampling Program, 1989 data  

SciTech Connect (OSTI)

Measurements of the concentrations of specific atmospheric radionuclides in air filter samples collected for the Environmental Measurements Laboratory's Surface Air Sampling Program (SASP) during 1989 indicate that anthropogenic radionuclides, in both hemispheres, were at or below the lower limits of detection for the analytical and sampling techniques that were used to measure them. During 1989, the occasional detection of {sup 137}Cs in some air filter samples may have resulted from resuspension of previously deposited debris. The naturally occurring radioisotopes that we measure, {sup 7}Be and {sup 210}Pb, continue to be detected in most air filter samples. The 1989 annual mean concentrations of {sup 7}Be at many of the sites were lower than those previously reported during the last decade. Possible changes in the atmospheric production of {sup 7}Be, variations in atmospheric circulation and precipitation patterns, as well as modifications to our sampling procedure many all have contributed to this observed trend. Short-term variations in the concentrations of {sup 7}Be and {sup 210}Pb continued to be observed at many sites at which weekly air filter samples were analyzed. These short-term fluctuations probably resulted from variations in meteorological factors. The data from our quality control samples indicate that the reliability of the air filter measurements are acceptable for their intended application.

Larsen, R.J.; Sanderson, C.G.

1991-08-01T23:59:59.000Z

417

EML Surface Air Sampling Program, 1989 data  

SciTech Connect (OSTI)

Measurements of the concentrations of specific atmospheric radionuclides in air filter samples collected for the Environmental Measurements Laboratory`s Surface Air Sampling Program (SASP) during 1989 indicate that anthropogenic radionuclides, in both hemispheres, were at or below the lower limits of detection for the analytical and sampling techniques that were used to measure them. During 1989, the occasional detection of {sup 137}Cs in some air filter samples may have resulted from resuspension of previously deposited debris. The naturally occurring radioisotopes that we measure, {sup 7}Be and {sup 210}Pb, continue to be detected in most air filter samples. The 1989 annual mean concentrations of {sup 7}Be at many of the sites were lower than those previously reported during the last decade. Possible changes in the atmospheric production of {sup 7}Be, variations in atmospheric circulation and precipitation patterns, as well as modifications to our sampling procedure many all have contributed to this observed trend. Short-term variations in the concentrations of {sup 7}Be and {sup 210}Pb continued to be observed at many sites at which weekly air filter samples were analyzed. These short-term fluctuations probably resulted from variations in meteorological factors. The data from our quality control samples indicate that the reliability of the air filter measurements are acceptable for their intended application.

Larsen, R.J.; Sanderson, C.G.

1991-08-01T23:59:59.000Z

418

Air transducers with high acoustic impedance  

Science Journals Connector (OSTI)

High?Z air transducers evolved from several industrial transducers. These predecessors include (a) acoustic emission and angle?beam NDT contact transducers; (b) flowmeter transducers for high?pressure methane hot refinery gases and corrosive flare gases; and (c) transducer arrays for monitoring hot corrosive gases flowing at Mach 0.1 in smokestacks of ?313 m. This peculiar ancestry accounts for their unusual high?acoustic?impedance construction. By not employing low?Z air?backed radiating membranes transducer bandwidth response time and sensitivity are sacrificed. The solid robust construction however offers some compensating features: tolerance to wide ranges in pressure and temperature including rapid rates of change (thermal shock depressurization); corrosion resistance; operable with standard lab equipment without bias voltage; mounting options where the transducer forms part of the pressure boundary or where it is outside the pressure boundary. Clamp?on air flow applications at one bar include small wind tunnels and plastic pipes. Acoustically isolated pairs measure secondary flow components (crossflow circulation) in a plane perpendicular to the pipe axis. Flow applications include gases such as air mild steam (pending) or other hot pressurized or corrosive fluids. Air?coupled measurements of transmission characteristics of wood or other low?density solids and air?ranging are readily demonstrated with the low?Z transducers.

Lawrence C. Lynnworth

1998-01-01T23:59:59.000Z

419

Hot Air Stratification of Ceiling Air Supply in a Large Space Building  

E-Print Network [OSTI]

ICEBO2006, Shenzhen, China Maximize Comfort: Temperature, Humidity and IAQ Vol.I-5-3 Hot Air Stratification of Ceiling Air Supply in a Large Space Building Hanqing Wang Zhiyong Wang Changrong Liu Ph.D. Professor Doctoral... of flow and temperature fields in atrium with ceiling height of 130 m [J]. ASHRAE Trans, 1995, 101(2): 1144-1157. [9] Wang han-qing, et al. Numerical simulation research on delaminating phenomena of ordinary air-conditional room [J]. Journal...

Wang, H.; Wang, Z.; Liu, C.

2006-01-01T23:59:59.000Z

420

Seminar 14 - Desiccant Enhanced Air Conditioning: Desiccant Enhanced Evaporative Air Conditioning (Presentation)  

SciTech Connect (OSTI)

This presentation explains how liquid desiccant based coupled with an indirect evaporative cooler can efficiently produce cool, dry air, and how a liquid desiccant membrane air conditioner can efficiently provide cooling and dehumidification without the carryover problems of previous generations of liquid desiccant systems. It provides an overview to a liquid desiccant DX air conditioner that can efficiently provide cooling and dehumidification to high latent loads without the need for reheat, explains how liquid desiccant cooling and dehumidification systems can outperform vapor compression based air conditioning systems in hot and humid climates, explains how liquid desiccant cooling and dehumidification systems work, and describes a refrigerant free liquid desiccant based cooling system.

Kozubal, E.

2013-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "kafb kirtland air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Air Electrode Design for Sustained High Power Operation of Li/air Batteries  

SciTech Connect (OSTI)

The rapid development of portable electronic devices increasingly requires much more energy to support advanced functions. However, currently available batteries do not meet the high energy requirement of these devices. Metal/air batteries, especially Li/air batteries, have a much higher specific energy than most other available batteries, but their power rate is limited by the accumulation of reaction products in the air electrode. Several approaches to improve the power rate of Li/air batteries have been analyzed in this work, including adjustment of air electrode porosity and catalyst reactivity distributions to minimize diffusion limitations and maximize air electrode material utilization. An interconnected dual pore system (one catalyzed and one noncatalyzed) is proposed to improve oxygen transport into the inner regions of the air electrode, but this approach alone cannot supply high power for long term applications. A time-release multiple catalyst approach is analyzed to provide temporal release of reactivity in the air electrode. When coupled with the dual pore configuration and catalysts with high reactivities, the time-release catalyst concept can extend the duration of higher powers to longer times, and result in maximum utilization of air electrode materials.

Williford, Ralph E.; Zhang, Jiguang

2009-08-31T23:59:59.000Z

422

E-Print Network 3.0 - air volume air Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Use Summary: pressure, and for modeling the change in system pressure as function of compressed air storage volume... important system variables such as system pressure and...

423

Evaluation of AirGIS: a GIS-based air pollution and human exposure modelling system  

Science Journals Connector (OSTI)

This study describes in brief the latest extensions of the Danish Geographic Information System (GIS)-based air pollution and human exposure modelling system (AirGIS), which has been developed in Denmark since 2001 and gives results of an evaluation with measured air pollution data. The system shows, in general, a good performance for both long-term averages (annual and monthly averages), short-term averages (hourly and daily) as well as when reproducing spatial variation in air pollution concentrations. Some shortcomings and future perspectives of the system are discussed too.

Matthias Ketzel; Ruwim Berkowicz; Martin Hvidberg; Steen Solvang Jensen; Ole Raaschou-Nielsen

2011-01-01T23:59:59.000Z

424

Abatement of Air Pollution: Air Pollution Control Equipment and Monitoring Equipment Operation (Connecticut)  

Broader source: Energy.gov [DOE]

These regulations contain instructions for the operation and monitoring of air pollution control equipment, as well as comments on procedures in the event of equipment breakdown, failure, and...

425

Thermal and air quality acceptability in buildings that reduce energy by reducing minimun airflow from overhead diffusers  

E-Print Network [OSTI]

assessments of indoor air-quality in five European122 D. Perceived air quality vs. binned zone air126 E. Perceived air quality vs. binned discharge air

2012-01-01T23:59:59.000Z

426

Combustion Air Preheat Should Be More Than Simply Recycling Energy  

E-Print Network [OSTI]

Combustion air preheat can and should result in fuel savings far in excess of the energy added to the combustion air. In a typical installation of air preheat on a fired tubular reactor, the addition of 2.5 million BTU/hr to the combustion air...

Grantom, R. L.

1980-01-01T23:59:59.000Z

427

Air pollution and asthma severity in adults Rage Estelle 1 *  

E-Print Network [OSTI]

INTRODUCTION Evidence of adverse effects of current air pollution on human health substantially increasedAir pollution and asthma severity in adults Rage Estelle 1 * , Siroux Val rieé 2 , K nzliü Nino 3 4 that exposure to air pollution affects asthma, but the effect of air pollution on asthma severity has not been

Paris-Sud XI, Université de

428

uide for the University of Utah Air Quality  

E-Print Network [OSTI]

pollution. Regulating air pollution is a priority of the federal government because air pollution can cause adverse health effects in humans.1 The Wasatch Front is plagued with poor air quality during the winter to trapped pollution. Air pollution in the Salt Lake Valley is characterized by high levels of particulate

Tipple, Brett

429

Session 2: Modelling air pollution across a range of scales  

E-Print Network [OSTI]

of Edinburgh BHF Centre for Cardiovascular Science Scottish Air Pollution and Health Workshop School;The health effects of air pollution The world-wide effects of air pollution are considerable MORTALITYSession 2: Modelling air pollution across a range of scales Ruth Doherty, Massimo Vieno, Ian Mac

430

Fault Tolerant Oxygen Control of a Diesel Engine Air System  

E-Print Network [OSTI]

Fault Tolerant Oxygen Control of a Diesel Engine Air System Rainer Nitsche Matthias Bitzer control problem of a Diesel engine air system having a jammed Exhaust Gas Recirculation (EGR) valve of the air system. Keywords: Fault tolerant control, Diesel engine, Air system, Model-based trajectory

Paris-Sud XI, Université de

431

Seawater Air Conditioning for Downtown Engineering Project Manager  

E-Print Network [OSTI]

Seawater Air Conditioning for Downtown Honolulu Scott Higa Engineering Project Manager Honolulu Seawater Air Conditioning, LLC Abstract As a tropical island state, Hawaii has a year-round demand for air conditioning. Conventional air conditioning systems are energy intensive and represent close to 50 percent

Frandsen, Jannette B.

432

Atmospheric Environment 38 (2004) 28412865 Cleaning products and air fresheners  

E-Print Network [OSTI]

Atmospheric Environment 38 (2004) 2841­2865 Cleaning products and air fresheners: exposure of certain cleaning products and air fresheners. In addition, many cleaning agents and air fresheners contain chemicals that can react with other air contaminants to yield potentially harmful secondary products

Short, Daniel

433

Executive Summary Critique Air Products and Chemicals, Inc.  

E-Print Network [OSTI]

ME440W Executive Summary Critique Air Products and Chemicals, Inc. Low Fin Tube Heat Exchanger as compared to the bare tubes. However, contrary to Air Products' argument that the heat exchangers were to reduce turbulence of the air before it reaches the fan. The inline fan pulls the air through the test

Demirel, Melik C.

434

INTEGRATION OF WIND TURBINES WITH COMPRESSED AIR ENERGY STORAGE  

E-Print Network [OSTI]

and an unpredictable nature, can be overcome. After an overview on storage systems, the Compressed Air

I. Arsie; V. Marano; G. Rizzo; M. Moran

435

How to Extract Energy from Dirty Interior Air  

E-Print Network [OSTI]

Industry is often faced with the problem of reducing the level of contaminated air in its plants. The common method used is to exhaust the dirty air and replace it with outside air. This requires heating or cooling of the replacement air. Two basic...

Cheney, W. A.

1982-01-01T23:59:59.000Z

436

Major: Ecological Systems Design, Air Quality Control and Waste Management  

E-Print Network [OSTI]

mechanics (Wang), 3 CP Air quality and health impact (Schleibinger, Wang, Wick), 3 CP Air Pollution Modeling pollution issues and control technology · Hands-on knowledge of state-of-the-art air quality monitoring questions · Solve complex problems from a system-oriented perspective · Understanding air pollution sources

Giger, Christine

437

Air Flow Distribution in the Sales Area of a Supermarket  

E-Print Network [OSTI]

temperature, air velocity and humidity in different zones. The results of a study of a sales area of a supermarket in Harbin are presented in this paper, including air temperature, air velocity and humidity. According to the assessment index of air flow...

Fang, X.; Song, C.; Zhao, J.; Wang, Z.

2006-01-01T23:59:59.000Z

438

POWER CHARACTERISTICS OF INDUSTRIAL AIR COMPRESSORS Chris Schmidt  

E-Print Network [OSTI]

of control, and potential problems such as inadequate compressed air storage, over-sized compressors are compared to suggested guidelines for energy-efficient air compression. INTRODUCTION Compressed air's annual electric costs, and the unit energy cost of compressed air ranges from about $0.15 to $0.35 per

Kissock, Kelly

439

RESIDENTIAL LOCATION CHOICE AND TRAVEL BEHAVIOR: IMPLICATIONS FOR AIR QUALITY  

E-Print Network [OSTI]

RESIDENTIAL LOCATION CHOICE AND TRAVEL BEHAVIOR: IMPLICATIONS FOR AIR QUALITY UC Davis-Caltrans Air Avenue Davis, CA 95616 Prepared for The California Department of Transportation Mike Brady, Air Quality control measure. #12;RESIDENTIAL LOCATION CHOICE AND TRAVEL BEHAVIOR: IMPLICATIONS FOR AIR QUALITY

Levinson, David M.

440

The University of Winnipeg Air Quality Management Policy  

E-Print Network [OSTI]

1 The University of Winnipeg Air Quality Management Policy TITLE: AIR QUALITY NUMBER: 90 & Sustainability) Purpose: The University of Winnipeg (the "University) Air Quality Management Policy ("Policy") establishes a framework within which the University will incorporate air quality management into its overall

Martin, Jeff

Note: This page contains sample records for the topic "kafb kirtland air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Predicting air quality in smart environments Seun Deleawea  

E-Print Network [OSTI]

attributable to air pollution, 1.5 million of these from indoor air pollution. Worldwide there are more deathsPredicting air quality in smart environments Seun Deleawea , Jim Kusznirb , Brian Lambb and Diane J that is often overlooked in maintaining a healthy lifestyle is the air quality of the environment. In this paper

Cook, Diane J.

442

Chapter 53 Ambient Air Quality (Kentucky) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

3 Ambient Air Quality (Kentucky) 3 Ambient Air Quality (Kentucky) Chapter 53 Ambient Air Quality (Kentucky) < Back Eligibility Agricultural Commercial Construction Developer Industrial Installer/Contractor Investor-Owned Utility Municipal/Public Utility Rural Electric Cooperative Utility Program Info State Kentucky Program Type Environmental Regulations Safety and Operational Guidelines Provider Kentucky Department for Environmental Protection Kentucky Administrative Regulation Chapter 53, entitled Ambient Air Quality, is promulgated under the authority of the Division of Air Quality within the Energy and Environment Cabinet's Department for Environmental Protection. Chapter 53 sets the air quality standards for pollutants regulated under the federally mandated Clean Air Act. The purpose of the

443

Air-Quality Improvement Tax Incentives | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Air-Quality Improvement Tax Incentives Air-Quality Improvement Tax Incentives Air-Quality Improvement Tax Incentives < Back Eligibility Commercial Industrial Savings Category Heating & Cooling Commercial Heating & Cooling Heating Cooling Other Appliances & Electronics Commercial Lighting Lighting Manufacturing Bioenergy Buying & Making Electricity Solar Water Heating Wind Program Info State Ohio Program Type Other Incentive Provider Ohio Air Quality Development Authority The Ohio Air Quality Development Authority (OAQDA) provides assistance for new air quality projects in Ohio, for both small and large businesses. For qualifying projects, the OAQDA also projects tax benefits. For qualifying projects, the Ohio Air Quality Development Authority (OAQDA) can provide a 100 percent exemption from the tangible personal property tax

444

Building Technologies Office: Energy-Efficient Window Air Conditioner  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Energy-Efficient Window Energy-Efficient Window Air Conditioner Ratings Research Project to someone by E-mail Share Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on Facebook Tweet about Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on Twitter Bookmark Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on Google Bookmark Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on Delicious Rank Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on Digg Find More places to share Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on

445

The Effect of Reduced Evaporator Air Flow on the Performance of a Residential Central Air Conditioner  

E-Print Network [OSTI]

This paper discusses the measured degradation in performance of a residential air conditioning system operating under reduced evaporator air flow. Experiments were conducted using a R-22 three-ton split-type cooling system with a short-tube orifice...

Palani, M.; O'Neal, D.; Haberl, J.

446

A dual pore carbon aerogel based air cathode for a highly rechargeable lithium-air battery  

Science Journals Connector (OSTI)

Abstract Cathode structure plays a vital role in lithium-air battery for that it can provide space for discharged products accommodation and free path for oxygen, e? and Li+ transport. However, pore blockage, cathode passivation and degradation all result in low discharge rates and poor cycling capability. To get rid of these predicaments, a novel highly conductive dual pore carbon aerogel based air cathode is fabricated to construct a lithium-air battery, which exhibits 18 to 525 cycles in the LiTFSI/sulfolane electrolyte at a current density varying from 1.00mAcm?2 to 0.05mAcm?2, accompanied by a high energy efficiency of 78.32%. We postulate that the essence lies in that the as-prepared air cathode inventively create a suitable tri-phase boundary reaction zone, facilitating oxygen and Li+ diffusion in two independant pore channels, thus realizing a relative higher discharge rate capability, lower pore blockage and cathode passivation. Further, pore structure, carbon loading, rate capability, discharge depth and the air's effect are exploited and coordinated, targeting for a high power and reversible lithium-air battery. Such nano-porous carbon aerogel air cathode of novel dual pore structure and material design is expected to be an attractive alternative for lithium-air batteries and other lithium based batteries.

Fang Wang; Yang-Hai Xu; Zhong-Kuan Luo; Yan Pang; Qi-Xing Wu; Chun-Sheng Liang; Jing Chen; Dong Liu; Xiang-hua Zhang

2014-01-01T23:59:59.000Z

447

CLEARING THE AIR? THE EFFECTS OF GASOLINE CONTENT REGULATION ON AIR QUALITY  

E-Print Network [OSTI]

CLEARING THE AIR? THE EFFECTS OF GASOLINE CONTENT REGULATION ON AIR QUALITY Maximilian Auffhammer and Ryan Kellogg* January 2009 Abstract This paper examines the effects of U.S. gasoline content gasoline markets and raise prices paid by consumers. We provide the first comprehensive empirical estimates

Edwards, Paul N.

448

Sources for Pu in near surface air  

SciTech Connect (OSTI)

This paper provides evidence that most of the Pu in the near surface air today is due to resuspension. Vertical and particle size distribution in near surface air over a period of three years were measured. The seasonal variations of Pu in air and the influence of meteorological parameters on these variations are shown. Samples were taken before the Chernobyl accident in an area where only Pu fallout from the atmospheric nuclear tests of the early sixties occurs. The comparison of the behavior of Pu with other trace elements, which were also measured, showed similar behavior of Pu and elements like Ca, Ti and Fe in near surface air. This confirms that most Pu is resuspended because the main source for these elements in air is the soil surface. Resuspension factors and resuspension rate are estimated for all measured elements. A resuspension factor of 0.8 X 10(-8) m-1 and a resuspension rate of 0.09 X 10(-9) s-1 is calculated for Pu.

Hartmann, G.; Thom, C.; Baechmann, K.

1989-01-01T23:59:59.000Z

449

Measure Guideline: Guide to Attic Air Sealing  

SciTech Connect (OSTI)

The Guide to Attic Air Sealing was completed in 2010 and although not in the standard Measure Guideline format, is intended to be a Measure Guideline on Attic Air Sealing. The guide was reviewed during two industry stakeholders meetings held on December 18th, 2009 and January 15th, 2010, and modified based on the comments received. Please do not make comments on the Building America format of this document. The purpose of the Guide to Attic Air Sealing is to provide information and recommendations for the preparation work necessary prior to adding attic insulation. Even though the purpose of this guide is to save energy - health, safety and durability should not be compromised by energy efficiency. Accordingly, combustion safety and ventilation for indoor air quality are addressed first. Durability and attic ventilation then follow. Finally, to maximize energy savings, air sealing is completed prior to insulating. The guide is intended for home remodelers, builders, insulation contractors, mechanical contractors, general contractors who have previously done remodeling and homeowners as a guide to the work that needs to be done.

Lstiburek, J.

2014-09-01T23:59:59.000Z

450

Buenos Aires, Argentina: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Buenos Aires, Argentina: Energy Resources Buenos Aires, Argentina: Energy Resources Jump to: navigation, search Equivalent URI DBpedia GeoNames ID 3435910 This article is a stub. You can help OpenEI by expanding it. Buenos Aires is the capital of Argentina. Contents 1 Registered Networking Organizations in Buenos Aires, Argentina 2 Registered Policy Organizations in Buenos Aires, Argentina 3 Registered Energy Companies in Buenos Aires, Argentina 4 References Registered Networking Organizations in Buenos Aires, Argentina Asociacion Argentina de Energia Eolica Registered Policy Organizations in Buenos Aires, Argentina Proyecto de Energias Renovables en Mercados Rurales Registered Energy Companies in Buenos Aires, Argentina Dalkia Argentina References Retrieved from "http://en.openei.org/w/index.php?title=Buenos_Aires,_Argentina&oldid=270464"

451

Alternative Fuels Data Center: Air Pollution Control Program  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Air Pollution Control Air Pollution Control Program to someone by E-mail Share Alternative Fuels Data Center: Air Pollution Control Program on Facebook Tweet about Alternative Fuels Data Center: Air Pollution Control Program on Twitter Bookmark Alternative Fuels Data Center: Air Pollution Control Program on Google Bookmark Alternative Fuels Data Center: Air Pollution Control Program on Delicious Rank Alternative Fuels Data Center: Air Pollution Control Program on Digg Find More places to share Alternative Fuels Data Center: Air Pollution Control Program on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Air Pollution Control Program The Air Pollution Control Program assists state, local, and tribal agencies in planning, developing, establishing, improving, and maintaining adequate

452

Analysis of the Interaction Between Air Transportation and Economic Activity: A Worldwide Perspective  

E-Print Network [OSTI]

Air transportation usage and economic activity are interdependent. Air transportation provides employment

Hansman, R. John

2009-03-30T23:59:59.000Z

453

Analysis of the Interaction Between Air Transportation and Economic Activity: A Worldwide Perspective  

E-Print Network [OSTI]

Air transportation usage and economic activity are interdependent. Air transportation provides employment

Ishutkina, Mariya A.

2011-10-14T23:59:59.000Z

454

Thermal decay in underfloor air distribution (UFAD) systems: Fundamentals and influence on system performance  

E-Print Network [OSTI]

Underfloor Air Distribution (UFAD) Design Guide. Atlanta:for design cooling loads in underfloor air distribution (

Lee, Kwang Ho; Schiavon, Stefano; Bauman, Fred; Webster, Tom

2012-01-01T23:59:59.000Z

455

IEA Heat Pump Conference 2011, 16 -19 May 2011, Tokyo, Japan ENERGY EFFICIENT AIR TO AIR HEAT PUMP OPERATING WITH  

E-Print Network [OSTI]

00149 -1- 10th IEA Heat Pump Conference 2011, 16 - 19 May 2011, Tokyo, Japan ENERGY EFFICIENT AIR TO AIR HEAT PUMP OPERATING WITH R-1234yf Sorina Mortada, Ph.D. student, Center for Energy and Processes Abstract: Significant improvements in energy performance of air-to-air heat pumps are the major reason

Paris-Sud XI, Université de

456

Indoor Air Quality Fact Sheet Poor indoor air quality comes from many sources. It can lead to suffering from lung  

E-Print Network [OSTI]

, and charcoal · Household products such as cleaners and pesticides How to Improve Indoor Air Quality · OpenIndoor Air Quality Fact Sheet Poor indoor air quality comes from many sources. It can lead Indoor Air Pollutants · Molds · Pollen · Dander from pet fur · Secondhand smoke · Formaldehyde · Fumes

457

Air Potato Leaf Feeding Beetle (Lilioceris cheni) Request Form/ Air Potato Vine (Dioscorea bulbifera) Infestation Site Record  

E-Print Network [OSTI]

Air Potato Leaf Feeding Beetle (Lilioceris cheni) Request Form/ Air Potato Vine: Longitude: Size/Density Approximate total size of the air potato vine infestation: Percent of the total area (above) covered by air potato vines (0100%): Other remarks: Please send data sheets to

Florida, University of

458

Abstract--For a Compressed Air Energy Storage (CAES) approach to be viable, the air compressor/expander must be  

E-Print Network [OSTI]

Abstract-- For a Compressed Air Energy Storage (CAES) approach to be viable, the air compressor improvement can also be determined using this method. I. INTRODUCTION novel Compressed Air Energy Storage advantage of pneumatics. High pressure (~20-30MPa) compressed air is stored in a dual chamber storage vessel

Li, Perry Y.

459

Air Quality Modeling in the South Coast Air Basin of California: What Do the Numbers Really Mean?  

E-Print Network [OSTI]

Air Quality Modeling in the South Coast Air Basin of California: What Do the Numbers Really Mean and Energy Program, University of California, Irvine, CA ABSTRACT This study evaluates air quality model. Comparison among CIT, California Photochemical Grid Model (CALGRID), and Urban Airshed Model air quality

Dabdub, Donald

460

Exploring the concept of compressed air energy storage (CAES) in lined rock caverns at shallow depth: A modeling study of air tightness and energy balance  

E-Print Network [OSTI]

wind- diesel-compressed air energy storage system for remotestudy for the compressed air energy storage technology bydesign of compressed air energy storage electric power

Kim, H.-M.

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "kafb kirtland air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Air Liquide - Biogas & Fuel Cells  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Liquide - Biogas & Fuel Cells Liquide - Biogas & Fuel Cells ■ Hydrogen Energy ■ Biogas Upgrading Technology 12 June 2012 Charlie.Anderson@airliquide.com 2 Air Liquide, world leader in gases for industry, health and the environment Renewable H 2 to Fuel Cell, Integrated Concept Purified Biogas 3 Air Liquide, world leader in gases for industry, health and the environment Renewable H 2 to Fuel Cell, Non-Integrated Concept Landfill WWTP digester Biogas membrane Pipeline quality methane CH4 Pipeline Hydrogen Production To Fuel Cell Vehicles Stationary Fuel Cells With H2 purification Stationary Fuel Cells Direct Conversion Directed Biomethane 4 Air Liquide, world leader in gases for industry, health and the environment Biogas Sources in the US ■ Landfill gas dominates (~4,000 Nm3/h typical)

462

Improving Air Conditioner and Heat Pump Modeling  

Broader source: Energy.gov (indexed) [DOE]

Improving Air-Conditioner Improving Air-Conditioner and Heat Pump Modeling Building America Stakeholders Meeting Jon Winkler March 2, 2012 2 * How do you recommend the most cost-effective A/C? Simple Question 3 Solution Whole-House Simulation Tool A/C Information * SEER 13 * SEER 14 * SEER 15 * SEER 16 * SEER 17 * SEER 18 * SEER 21 Annualized Cooling Cost (Energy + Equipment) 4 Background * Power, capacity and SHR vary with: o Outdoor temperature o Entering wetbulb o Air mass flow rate o Part load ratio Power Sensible Capacity Latent Capacity * How to accurately and easily model A/C performance? 5 Background: Model Development * A/C modeling utilizes two types of input o Rated values (capacity, efficiency, etc.) o Performance curves Capacity 1 / Efficiency 6 Background: Manufacturer's Data

463

ARM - Campaign Instrument - rad-air  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

govInstrumentsrad-air govInstrumentsrad-air Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send Campaign Instrument : Airborne Radiometers (RAD-AIR) Instrument Categories Radiometric, Airborne Observations Campaigns Indirect and Semi-Direct Aerosol Campaign (ISDAC) [ Download Data ] North Slope Alaska, 2008.04.01 - 2008.04.30 Routine AAF CLOWD Optical Radiative Observations (RACORO) [ Download Data ] Southern Great Plains, 2009.01.22 - 2009.06.30 Routine AAF CLOWD Optical Radiative Observations (RACORO) [ Download Data ] Southern Great Plains, 2009.01.22 - 2009.06.30 Routine AAF CLOWD Optical Radiative Observations (RACORO) [ Download Data ] Southern Great Plains, 2009.01.22 - 2009.06.30 Primary Measurements Taken The following measurements are those considered scientifically relevant.

464

A Survey: Indoor Air Quality in Schools  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

3 3 A Survey: Indoor Air Quality in Schools We recently undertook a survey and critical review of the published literature on indoor air quality (IAQ), ventilation, and IAQ- and building-related health problems in schools, particularly those in the state of California. The survey's objectives included identifying the most commonly reported building-related health symptoms involving schools, and assembling and evaluating existing measurement data on key indoor air pollutants most likely to be related to these symptoms. The review also summarizes existing measurements of ventilation rates in schools and information on the causes of IAQ and health problems in schools. Most of the literature we reviewed (more than 450 articles and reports) dealt with complaint or problem schools. Among the papers were

465

East Mountain Area 1995 air sampling results  

SciTech Connect (OSTI)

Ambient air samples were taken at two locations in the East Mountain Area in conjunction with thermal testing at the Lurance Canyon Burn Site (LCBS). The samples were taken to provide measurements of particulate matter with a diameter less than or equal to 10 micrometers (PM{sub 10}) and volatile organic compounds (VOCs). This report summarizes the results of the sampling performed in 1995. The results from small-scale testing performed to determine the potentially produced air pollutants in the thermal tests are included in this report. Analytical results indicate few samples produced measurable concentrations of pollutants believed to be produced by thermal testing. Recommendations for future air sampling in the East Mountain Area are also noted.

Deola, R.A. [Sandia National Labs., Albuquerque, NM (United States). Air Quality Dept.

1996-09-01T23:59:59.000Z

466

Air-driven Brazil nut effect  

Science Journals Connector (OSTI)

A large heavy object may rise to the top of a bed of smaller particles under the influence of vertical vibration, the Brazil nut effect. Recently it has been noted that interstitial air can influence the Brazil nut rise time. Here we report that the air movement induced by vertical vibration produces a very strong Brazil nut effect for fine granular beds. We use a porous-bottomed box to investigate the mechanism responsible for this effect and to demonstrate that it is related to the piling of fine beds, first reported by Chladni and studied by Faraday. Both effects are due to the strong interaction of the fine particles with the air, as it is forced through the bed by the vibration.

M. A. Naylor; Michael R. Swift; P. J. King

2003-07-21T23:59:59.000Z

467

Helium corona-assisted air discharge  

SciTech Connect (OSTI)

Operation of atmospheric discharge of electronegative gases including air at low voltages yet without consuming any inert gas will enormously promote the application of non-thermal plasmas. By taking advantage of the low onset voltage for helium corona, air discharge was successfully launched at much reduced voltages with a needle-plate system partly contained in a helium-filled glass bulb--for a needle-plate distance of 12 mm, 1.0 kV suffices. Ultraviolet emission from helium corona facilitates the discharging of air, and the discharge current manifests distinct features such as relatively broad Trichel pulses in both half periods. This design allows safe and economic implementation of atmospheric discharge of electronegative gases, which will find a broad palette of applications in surface modification, plasma medicine and gas treatment, etc.

Jiang Nan; Gao Lei; Ji Ailing; Cao Zexian [Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China)

2011-10-15T23:59:59.000Z

468

Solar Powered Radioactive Air Monitoring Stations  

SciTech Connect (OSTI)

Environmental monitoring of ambient air for radioactive material is required as stipulated in the PNNL Site radioactive air license. Sampling ambient air at identified preferred locations could not be initially accomplished because utilities were not readily available. Therefore, solar powered environmental monitoring systems were considered as a possible option. PNNL purchased two 24-V DC solar powered environmental monitoring systems which consisted of solar panels, battery banks, and sampling units. During an approximate four month performance evaluation period, the solar stations operated satisfactorily at an on-site test location. They were subsequently relocated to their preferred locations in June 2012 where they continue to function adequately under the conditions found in Richland, Washington.

Barnett, J. M.; Bisping, Lynn E.; Gervais, Todd L.

2013-10-30T23:59:59.000Z

469

Air separation by the Moltox process  

SciTech Connect (OSTI)

The report describes results of a development program on a new and energy saving process for air separation. The Moltox process involves reversibly reacting oxygen in air with a recirculating salt solution, such that oxygen is extracted without depressurizing the remaining nitrogen. Energy savings of approximately 50% are indicated for this process compared to conventional cryogenic air separation. The development program consisted of design, construction, and operation of a 6 liter/minute pilot plant; optimization of the process flowsheet through computer modelling; investigation of engineering aspects of the process including corrosion, safety, and NO/sub x/ generation; and an economic comparison to conventional cryogenic practice. All objectives were satisfactorily achieved except for continuous operation of the pilot plant, and the modifications necessary to achieve that have been identified. Economically the Moltox process shows a substantial advantage over large scale cryogenic plants which are powered by fuel vice electricity.

Erickson, D. C.

1981-04-01T23:59:59.000Z

470

Secondary air injection system and method  

DOE Patents [OSTI]

According to one embodiment of the invention, a secondary air injection system includes a first conduit in fluid communication with at least one first exhaust passage of the internal combustion engine and a second conduit in fluid communication with at least one second exhaust passage of the internal combustion engine, wherein the at least one first and second exhaust passages are in fluid communication with a turbocharger. The system also includes an air supply in fluid communication with the first and second conduits and a flow control device that controls fluid communication between the air supply and the first conduit and the second conduit and thereby controls fluid communication to the first and second exhaust passages of the internal combustion engine.

Wu, Ko-Jen; Walter, Darrell J.

2014-08-19T23:59:59.000Z

471

Air Quality in Lanzhou, a Major Industrial City in China: Characteristics of Air Pollution and Review of Existing Evidence from Air Pollution and Health Studies  

Science Journals Connector (OSTI)

Air pollution contributes substantially to global health burdens; however, less is known about pollution patterns in China and whether they differ ... . We evaluated temporal and spatial heterogeneity of air pollution

Yaqun Zhang; Min Li; Mercedes A. Bravo; Lan Jin

2014-10-01T23:59:59.000Z

472

Indoor air quality: The legal landscape II  

SciTech Connect (OSTI)

Today`s office environment is as different from its predecessor as an automobile is from a horse and buggy. A 1950s office typically contained tile floors, painted walls, plaster ceilings, carbon paper, and plentiful fresh air circulating through windows that were usually open when weather permitted. In the 1990s, the decor has shifted to carpeted floors, synthetic wall coverings, ceiling tile and multiple copiers. Sophisticated building materials and motorized office products can emit unwelcome constituents into the indoor air, yet ventilation is limited by windows that do not open. One result of these changes has been an unprecedented and ever-increasing concern about indoor air quality (IAQ). Some studies rank indoor air pollution as today`s number one environmental health risk. Increased media attention to the topic has increased public awareness, which has increased litigation and regulatory activity in the area. This paper explores the legal landscape of IAQ in the US, ranging from legislative to regulatory activity on both the federal and state levels, and from civil litigation to actions brought before administrative boards. Along the way, the paper defines and discusses such IAQ problems as building-related illness (BRI) and sick building syndrome (SBS), examining the magnitude of the problems and their possible causes. Finally, the paper provides suggestions to those potentially liable for alleged injuries from indoor air pollution, including architects, builders, contractors, building product manufacturers, building owners and managers, building sellers, employers, and engineering and environmental consultants. This paper is an update of a paper presented at the Air and Waste Management Association`s Annual Meeting in 1992.

Neet, J.O. Jr.; Smith, T.A. [Shook, Hardy and Bacon, Kansas City, MO (United States)

1997-12-31T23:59:59.000Z

473

AIRMaster: Compressed air system audit software  

SciTech Connect (OSTI)

The project goal was to develop a software tool, AIRMaster, and a methodology for performing compressed air system audits. AIRMaster and supporting manuals are designed for general auditors or plant personnel to evaluate compressed air system operation with simple instrumentation during a short-term audit. AIRMaster provides a systematic approach to compressed air system audits, analyzing collected data, and reporting results. AIRMaster focuses on inexpensive Operation and Maintenance (O and M) measures, such as fixing air leaks and improving controls that can significantly improve performance and reliability of the compressed air system, without significant risk to production. An experienced auditor can perform an audit, analyze collected data, and produce results in 2--3 days. AIRMaster reduces the cost of an audit, thus freeing funds to implement recommendations. The AIRMaster package includes an Audit Manual, Software and User's manual, Analysis Methodology Manual, and a Case Studies summary report. It also includes a Self-Guided Tour booklet to help users quickly screen a plant for efficiency improvement potentials, and an Industrial Compressed Air Systems Energy Efficiency Guidebook. AIRMaster proved to be a fast and effective audit tool. In sever audits AIRMaster identified energy savings of 4,056,000 kWh, or 49.2% of annual compressor energy use, for a cost savings of $152,000. Total implementation costs were $94,700 for a project payback period of 0.6 years. Available airflow increased between 11% and 51% of plant compressor capacity, leading to potential capital benefits from 40% to 230% of first year energy savings.

Wheeler, G.M.; Bessey, E.G.; McGill, R.D.; Vischer, K.

1997-07-01T23:59:59.000Z

474

REVIEW OF AIR FLOW MEASUREMENT TECHNIQUES  

Office of Scientific and Technical Information (OSTI)

9747 9747 Review of Airflow Measurement Techniques Jennifer McWilliams Energy Performance of Buildings Group Environmental Energy Technologies Division Lawrence Berkeley National Laboratory Berkeley, CA 94720 December 1, 2002 Abstract Airflow measurement techniques are necessary to determine the most basic of indoor air quality questions: "Is there enough fresh air to provide a healthy environment for the occupants of the building?" This paper outlines airflow measurement techniques, but it does not make recommendations for techniques that should be used. The airflows that will be discussed are those within a room or zone, those between rooms or zones, such as through doorways (open or closed) or passive vents, those between the building and

475

Controlled air incinerator conceptual design study  

SciTech Connect (OSTI)

This report presents a conceptual design study for a controlled air incinerator facility for incineration of low level combustible waste at Three Mile Island Unit 2 (TMI-2). The facility design is based on the use of a Helix Process Systems controlled air incinerator. Cost estimates and associated engineering, procurement, and construction schedules are also provided. The cost estimates and schedules are presented for two incinerator facility designs, one with provisions for waste ash solidification, the other with provisions for packaging the waste ash for transport to an undefined location.

Not Available

1982-01-01T23:59:59.000Z

476

Measured Impacts of Air Conditioner Condenser Shading  

E-Print Network [OSTI]

reaching the expansion valve. In theory, the efficiency of vapor compression air conditioning can be improved through two primary mechanisms associated with condenser shading: Direct shading. Incident solar radiation can pose approximately a 1,000 w...]: IEYPERAlURL COUPARlSOn A/C SHADING DP. 1 (Some): SOUR RADlAllON COUPARISON I=AYEI[Nl KYP orq=82.1 , mu=87.(22 Z=CONDEHSIR ARU AIR lEYP orq=83.8 , mox=02.858 TIME OF DAY, (hr) 9 12 15 TIME OF DAY, (hr) Figure 3. Sample daily 15-minute data for June 21...

Parker, D. S.; Barkaszi, S. F.; Sonne, J. K.

1996-01-01T23:59:59.000Z

477

Cooling air duct and screen arrangement for an air cooled engine  

SciTech Connect (OSTI)

This patent describes a cooling air duct and screen arrangement for an air cooled engine which includes an improved cooling air system for ensuring a supply of relatively clean air for ingestion by the cooling shroud, which consists of: a vertical transverse baffle mounted to the frame and fitting closely against a forward top portion of the shroud and having an edge shaped complementary to and disposed at least closely adjacent the hood. An air duct is mounted to the frame and has an upright rear wall seated against the front of the shroud in an area surrounding the inlet. The air duct further has an upright front wall and a connecting wall joining respective side and bottom edges of the front and rear walls and cooperating therewith to define an upwardly facing opening. A screen is located forwardly of the baffle and has a top and front joined by opposite sides with the top and opposite sides having rear edges mounted against the baffle and with the opposite sides and front having bottom edges engaged with the air duct about the upwardly facing opening wherein the screen is mounted solely to the baffle by connection means including a vertical guide means provided on the forward side of the baffle and flange means formed on the screen and being vertically slidably received in the guide means.

Hoch, J.J.; Stricker, D.K.

1986-03-04T23:59:59.000Z

478

Alternative Fuels Data Center: Fueling Station Air Quality Permit Exemption  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Fueling Station Air Fueling Station Air Quality Permit Exemption to someone by E-mail Share Alternative Fuels Data Center: Fueling Station Air Quality Permit Exemption on Facebook Tweet about Alternative Fuels Data Center: Fueling Station Air Quality Permit Exemption on Twitter Bookmark Alternative Fuels Data Center: Fueling Station Air Quality Permit Exemption on Google Bookmark Alternative Fuels Data Center: Fueling Station Air Quality Permit Exemption on Delicious Rank Alternative Fuels Data Center: Fueling Station Air Quality Permit Exemption on Digg Find More places to share Alternative Fuels Data Center: Fueling Station Air Quality Permit Exemption on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Fueling Station Air Quality Permit Exemption

479

Keystone Clean Air | Open Energy Information  

Open Energy Info (EERE)

Clean Air Clean Air Jump to: navigation, search Logo: Keystone Clean Air Name Keystone Clean Air Address 123 Pembroke Ct. Place Exton, Pennsylvania Zip 19341 Sector Efficiency Product KVAR Energy Controller - capacitors Year founded 1996 Number of employees 1-10 Phone number 610-363-7649 Website http://www.slideshare.net/toml Coordinates 40.0571015°, -75.6367661° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":40.0571015,"lon":-75.6367661,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

480

Air pollution, the automobile, and public health  

SciTech Connect (OSTI)

The author reviews a volume of articles written by experts in the study of air pollution and its effects. The Health Effects Institute, based in Cambridge, Massachusetts, commissioned the articles. Described as an excellent review of scientific and technological work in the field, its weakness is a failure to adequately address risk assessment.

Wilson, R.

1989-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "kafb kirtland air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Feasibility of Air Capture Manya Ranjan  

E-Print Network [OSTI]

benefits of air capture, reported in literature, are that it allows us to reduce the atmospheric carbon process to capture CO2 and biomass coupled with carbon capture and sequestration, which utilizes coupled with carbon capture and sequestration looks more promising from a cost perspective. This work puts

482

Radionuclide Air Emission Report May 21, 2007  

E-Print Network [OSTI]

Environment, Safety, and Health Division Ernest Orlando Lawrence Berkeley National Laboratory Prepared Lawrence Berkeley National Laboratory Operation Office Information Office: U.S. Department of Energy Radionuclide Air Emission Report for 2006 (in compliance with 40 CFR 61, Subpart H) Site Name: Ernest Orlando

483

Jeff Chamberlain on Lithium-air batteries  

ScienceCinema (OSTI)

Jeff Chamberlain, technology transfer expert at Argonne National Laboratory, speaks on the new technology Lithium-air batteries, which could potentially increase energy density by 5-10 times over lithium-ion batteries. More information at http://www.anl.gov/Media_Center/News/2009/batteries090915.html

Chamberlain, Jeff

2013-04-19T23:59:59.000Z

484

CHAPTER ____ THE AIR-WATER INTERFACE: TURBULENCE  

E-Print Network [OSTI]

.g. from paper mills. The desorption of dissolved substances, like PCBs, from inland and coastal water at an unsheared air-water interface, i.e., a situation in which the winds are light and the fluid motions category, we consider situations with significant wind shear at the surface. In this case, the turbulence

California at Santa Barbara, University of

485

Jeff Chamberlain on Lithium-air batteries  

SciTech Connect (OSTI)

Jeff Chamberlain, technology transfer expert at Argonne National Laboratory, speaks on the new technology Lithium-air batteries, which could potentially increase energy density by 5-10 times over lithium-ion batteries. More information at http://www.anl.gov/Media_Center/News/2009/batteries090915.html

Chamberlain, Jeff

2009-01-01T23:59:59.000Z

486

Air quality in the Carlsbad cavern  

SciTech Connect (OSTI)

The air quality in the Carlsbad Cavern has been investigated, but there are no reports on radon progeny and aerosols. The purpose of this experiment was to determine the activity size distribution of radon progeny and the air exchange rate inside the Cavern. Teams from ITRI and New Mexico Institute of Mining and Technology (NMT) conducted the field study in July 1994. The ITRI graded diffusion battery (GDB) was used to determine the activity size distribution, progeny concentration, equilibrium factor, and unattached fraction of the radon progeny. The design, calibration, and performance of the GDB have been described. For this study, each stage of the GDB contained one stainless steel screen, with the mesh sizes arranged in a series of 30, 50, 145, 200, and 635 mesh from the air inlet to the outlet. A 47-nm type A/E glass fiber filter was used to collect all particles that penetrated the screens. The flow rate was 5 L/min. The average ventilation rate in the cavern is 0.0026 V/hr. Our results showed that the cavern atmosphere may be quite different from other underground environments. The atmosphere in the summer is stable and relatively free of airborne particles, partly due to the extremely slow air exchange rate.

Cheng, Yung-Seng; Chen, Tou-Rong [Tsing-Hua Univ. (Taiwan, Province of China); Wasiolek, P.T. [New Mexico Institute of Mining and Technology, Socorro, NM (United States)

1994-11-01T23:59:59.000Z

487

Indoor air pollution: a public health perspective  

Science Journals Connector (OSTI)

...systems to comply with new ASHRAE standard 62-1981 Provide for separation...ordinances, or performance standards to protect the public Provide...equipment, and performance of HVAC systems Table 4. Components...Recodification of air contaminant standards," Fed. Regist. 40, 23072...

JD Spengler; K Sexton

1983-07-01T23:59:59.000Z

488

Clearing the air with natural gas engines  

SciTech Connect (OSTI)

This article examines the increased popularity of natural gas vehicles which has spurred engine designers to manipulate fuel-air ratios, compression ratios, ignition timing, and catalytic converters in ways to minimize exhaust pollutants. The topics of the article include reducing pollutants, high-octane engineering, diesel to natural gas, and the two-fuel choice.

O'Connor, L.

1993-10-01T23:59:59.000Z

489

Air Resources Laboratory Publications FY 2002  

E-Print Network [OSTI]

." Journal of Atmospheric Sciences 59:2605-2607 (2002). Angell, J.K. Relation of size and displacement. Preprints, 4th Conference on Atmospheric Chemistry: Urban, Regional and Global-Scale Impacts of Air Pollutants, January 13­17, Orlando, FL. American Meteorological Society, Boston, 97­102 (2002). Baldocchi, D

490

Central Air Conditioner Enforcement Policy Statement  

Broader source: Energy.gov [DOE]

DOE will not seek civil penalties for violations of the regional standards applicable to central air conditioners that occur prior to July 1, 2016, provided that the violations are related to the distribution in commerce of units manufactured prior to January 1, 2015.

491

Covered Product Category: Room Air Conditioners  

Broader source: Energy.gov [DOE]

FEMP provides acquisition guidance across a variety of product categories, including room air conditioners, which are an ENERGY STAR-qualified product category. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

492

Covered Product Category: Residential Central Air Conditioners  

Broader source: Energy.gov [DOE]

FEMP provides acquisition guidance across a variety of product categories, including residential central air conditioners (CACs), which are an ENERGY STAR-qualified product category. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

493

Combustion Air Preheat on Steam Cracker Furnaces  

E-Print Network [OSTI]

Industrial Energy Technology Conference Volume II, Houston, TX, April 17-20, 1983 FIGURE 6 TYPICAL SEAL ARRANGEMENT FIGURE 1 TYPICAL CHANGEOVER PATTERN 50 GAS TURBlNEICRACKlNO FOONACE SYSTEM GTE/AIR FLOW VI nME O...-_T.,.;'..;.;,M;,;;;E;.:"? .;;.S...

Kenney, W. F.

1983-01-01T23:59:59.000Z

494

AIR-RAID DAMAGED AND ELECTRICITY SUPPLY  

Science Journals Connector (OSTI)

... Review record instances of the air-raid damage sustained by overhead lines, cables, and substation equipment, and the steps taken to effect repairs and restore supply (see also NATUBE ... only a slight puncturing of the casing. As an indication of the amount of damage substation equipment can withstand, a switchboard which was blown right out by blast needed only ...

1942-03-28T23:59:59.000Z

495

Optical guiding of absorbing nanoclusters in air  

E-Print Network [OSTI]

Optical guiding of absorbing nanoclusters in air Vladlen G. Shvedov1-3, Anton S. Desyatnikov1124@rsphysse.anu.edu.au Abstract: We suggest a novel approach in all-optical trapping employing number of particles in a dual beam optical trap created by two counter-propagating and co

496

Alternative Refrigerants for Building Air Conditioning  

E-Print Network [OSTI]

The majority of building air conditioning has traditionally been achieved with vapor compression technology using CFC-I I or HCFC-22 as refrigerant fluids. CFC-11 is being successfully replaced by HCFC-123 (retrofit or new equipment) or by HFC- 134a...

Bivens, D. B.

1996-01-01T23:59:59.000Z

497

Analysis of Air Leakage Measurements from Residential  

E-Print Network [OSTI]

that are rated for energy efficiency have normalized leakage values that are, on average, 30% lower than non% of the total energy consumption by US households, and air leakage is estimated to account for 30 to 50 homes. This work enables software tools such as Home Energy Saver to more reliably predict the energy

498

Pilot light in the air conditioner  

SciTech Connect (OSTI)

The California Energy Commission (CEC) recently modified its Residential Energy Standards Point Program to include the electricity consumed by crankcase heaters in air conditioners and heat pumps. Turning off the unit during the off season can save the homeowner a few bucks per month. 2 references, 1 figure.

Kovach, A.; Meier, A.

1987-09-01T23:59:59.000Z

499

Determination of Radon and Thoron in Air  

Science Journals Connector (OSTI)

... A method for determination of radon favoured by the later investigators has been filtration of about 1 cubic metre of air ... of the activity found on the filter using a particle counter or ionization chamber ; radon passes through the filter and the short-lived activity observed is that of the four ...

G. B. COURTIER

1957-08-24T23:59:59.000Z

500

NOAA Air Resources Laboratory Monthly Activity Report  

E-Print Network [OSTI]

. Perfluorocarbon Tracer Analysis Development 11. Radar Wind Profiler 12. Transport and Dispersion Modeling 13. Coordination with BEA Emergency Management Group 14. SORD Review 15. WRF Model 16. Mesoscale Modeling 17. Air of the local NOX sources within the watershed on N deposition to the watershed and bay, supplemented