Powered by Deep Web Technologies
Note: This page contains sample records for the topic "insar injectivity test" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Injectivity Test | Open Energy Information  

Open Energy Info (EERE)

Injectivity Test Injectivity Test Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: Injectivity Test Details Activities (7) Areas (6) Regions (0) NEPA(1) Exploration Technique Information Exploration Group: Downhole Techniques Exploration Sub Group: Well Testing Techniques Parent Exploration Technique: Well Testing Techniques Information Provided by Technique Lithology: Stratigraphic/Structural: Hydrological: Permeability of the well Thermal: Dictionary.png Injectivity Test: A well testing technique conducted upon completion of a well. Water is pumped into the well at a constant rate until a stable pressure is reached then the pump is turned off and the rate at which pressure decreases is measured. The pressure measurements are graphed and well permeability can

2

Operational experience during the LHC injection tests  

E-Print Network (OSTI)

Following the LHC injection tests of 2008. two injection tests took place in October and November 2009 as preparation for the LHC restart on November 20, 2009. During these injection tests beam was injected through the TI 2 transfer line into sector 23 of ring 1 and through TI 8 into the sectors 78, 67 and 56 of ring 2. The beam time was dedicated to injection steering, optics measurements and debugging of all the systems involved. Because many potential problems were sorted out in advance, these tests contributed to the rapid progress after the restart. This paper describes the experiences and issues encountered during these tests as well as related measurement results.

Fuchsberger, K; Arduini, G; Assmann, R; Bailey, R; Bruning, O; Goddard, B; Kain, V; Lamont, M; MacPherson, A; Meddahi, M; Papotti, G; Pojer, M; Ponce, L; Redaelli, S; Solfaroli Camillocci, M; Venturini Delsolaro, W; Wenninger, J

2010-01-01T23:59:59.000Z

3

Injectivity Testing for Vapour Dominated Feed Zones  

DOE Green Energy (OSTI)

Wells with vapor dominated feed zones yield abnormal pressure data. This is caused by the condensation of vapor during water injection. A revised injectivity test procedure currently applied by PNOC at the Leyte Geothermal Power Project has improved the injectivity test results.

Clotworthy, A.W.; Hingoyon, C.S.

1995-01-01T23:59:59.000Z

4

Definition: Injectivity Test | Open Energy Information  

Open Energy Info (EERE)

Definition Definition Edit with form History Facebook icon Twitter icon » Definition: Injectivity Test Jump to: navigation, search Dictionary.png Injectivity Test A well testing technique conducted upon completion of a well. Water is pumped into the well at a constant rate until a stable pressure is reached then the pump is turned off and the rate at which pressure decreases is measured. The pressure measurements are graphed and well permeability can be calculated.[1] References ↑ https://pangea.stanford.edu/ERE/pdf/IGAstandard/ISS/2008Croatia/Hole03.pdf Ret LikeLike UnlikeLike You and one other like this.One person likes this. Sign Up to see what your friends like. rieved from "http://en.openei.org/w/index.php?title=Definition:Injectivity_Test&oldid=688681"

5

Alabama Injection Project Aimed at Enhanced Oil Recovery, Testing...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Alabama Injection Project Aimed at Enhanced Oil Recovery, Testing Important Geologic CO2 Storage Alabama Injection Project Aimed at Enhanced Oil Recovery, Testing Important...

6

Trona Injection Tests: Mirant Potomac River Station, Unit 1,...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Trona Injection Tests: Mirant Potomac River Station, Unit 1, November 12 to December 23, 2005, Summary Report Trona Injection Tests: Mirant Potomac River Station, Unit 1, November...

7

Injectivity Test At Raft River Geothermal Area (1979) | Open Energy  

Open Energy Info (EERE)

Injectivity Test At Raft River Geothermal Area (1979) Injectivity Test At Raft River Geothermal Area (1979) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Injectivity Test At Raft River Geothermal Area (1979) Exploration Activity Details Location Raft River Geothermal Area Exploration Technique Injectivity Test Activity Date 1979 Usefulness useful DOE-funding Unknown Notes Quantification of the pressure response prior to 600 minutes is not always possible. Short-duration (< 24-hour) injection or pump tests are conducted with the drilling rig equipment, and long-duration (21-day) injection and pump tests are then conducted with the permanent pumping facilities. References Allman, D. W.; Goldman, D.; Niemi, W. L. (1 January 1979) Evaluation of testing and reservoir parameters in geothermal wells at Raft

8

Injectivity Test At Fenton Hill Hdr Geothermal Area (Grigsby...  

Open Energy Info (EERE)

navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Injectivity Test At Fenton Hill Hdr Geothermal Area (Grigsby, Et Al., 1983) Exploration Activity Details...

9

Resistivity measurements before and after injection Test 5 at...  

Open Energy Info (EERE)

Facebook icon Twitter icon Resistivity measurements before and after injection Test 5 at Raft River KGRA, Idaho. Final report Jump to: navigation, search GEOTHERMAL...

10

Nonisothermal injection tests in fractured reservoirs  

DOE Green Energy (OSTI)

The paper extends the analysis of nonisothermal pressure transient data to fractured reservoirs. Two cases are considered: reservoirs with predominantly horzontal fractures and reservoirs with predominantly vertical fractures. Effects of conductive heat transfer between the fractures and the rock matrix are modeled, and the resulting pressure transients evaluated. Thermal conduction tends to retard the movement of the thermal front in the fractures, which significantly affects the pressure transient data. The purpose of the numerical simulation studies is to provide methods for analyzing nonisothermal injection/falloff data for fractured reservoirs.

Cox, B.L.; Bodvarsson, G.S.

1985-01-01T23:59:59.000Z

11

Fractured reservoir characterization through injection, falloff, and flowback tests  

SciTech Connect

This paper presents the development of a multiphase pressure-transient-analysis technique for naturally fractured reservoirs and the analysis of a series of field tests performed to evaluate the water injection potential and the reservoir characteristics of a naturally fractured reservoir. These included step-rate, water-injectivity, pressure-falloff, and flowback tests. Through these tests, a description of the reservoir was obtained.

Peng, C.P.; Singh, P.K. (Amoco Production Co., Tulsa, OK (United States)); Halvorsen, H. (Amoco Norway Oil Co., Stavanger (NO)); York, S.D. (Amoco Production Co., Houston, TX (United States))

1992-09-01T23:59:59.000Z

12

Detecting and monitoring UCG subsidence with InSAR  

Science Conference Proceedings (OSTI)

The use of interferometric synthetic aperture radar (InSAR) to measure surface subsidence caused by Underground Coal Gasification (UCG) is tested. InSAR is a remote sensing technique that uses Synthetic Aperture Radar images to make spatial images of surface deformation and may be deployed from satellite or an airplane. With current commercial satellite data, the technique works best in areas with little vegetation or farming activity. UCG subsidence is generally caused by roof collapse, which adversely affects UCG operations due to gas loss and is therefore important to monitor. Previous studies have demonstrated the usefulness of InSAR in measuring surface subsidence related to coal mining and surface deformation caused by a coal mining roof collapse in Crandall Canyon, Utah is imaged as a proof-of-concept. InSAR data is collected and processed over three known UCG operations including two pilot plants (Majuba, South Africa and Wulanchabu, China) and an operational plant (Angren, Uzbekistan). A clear f eature showing approximately 7 cm of subsidence is observed in the UCG field in Angren. Subsidence is not observed in the other two areas, which produce from deeper coal seams and processed a smaller volume. The results show that in some cases, InSAR is a useful tool to image UCG related subsidence. Data from newer satellites and improved algorithms will improve effectiveness.

Mellors, R J; Foxall, W; Yang, X

2012-03-23T23:59:59.000Z

13

Interpretation of self-potential measurements during injection tests at  

Open Energy Info (EERE)

self-potential measurements during injection tests at self-potential measurements during injection tests at Raft River, Idaho. Final report Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Report: Interpretation of self-potential measurements during injection tests at Raft River, Idaho. Final report Details Activities (1) Areas (1) Regions (0) Abstract: Self-potential measurements before and during injection tests at Raft River KGRA, Idaho indicate a small negative change. The magnitude of the change (5 to 10 mV) is near the noise level (5 mV) but they extend over a fairly broad area. The presence of a cathodic protection system clouds the issue of the validity of the changes, however the form of the observed changes cannot be explained by any simple change in the current strength of the protection system. Furthermore, similar changes are observed for two

14

Victor J. Daniel Jr. CO2 Injection Test Site Plan  

NLE Websites -- All DOE Office Websites (Extended Search)

Mississippi Test Site JAF02664.PPT 1 1.1 SITE BACKGROUND 1.2 GENERAL IDENTIFICATION DATA 1.3 REGULATORY CLASSIFICATION 1.4 WELL DATA - INJECTION WELL NO. 1 1.5 WELL DATA -...

15

Advanced InSAR Techniques for Geothermal Exploration and Production | Open  

Open Energy Info (EERE)

Advanced InSAR Techniques for Geothermal Exploration and Production Advanced InSAR Techniques for Geothermal Exploration and Production Jump to: navigation, search OpenEI Reference LibraryAdd to library Journal Article: Advanced InSAR Techniques for Geothermal Exploration and Production Abstract InSAR is a remote sensing tool that has applications in both geothermal exploration and in the management of producing fields. The technique has developed rapidly in recent years and the most evolved algorithms, now capable of providing precise ground movement measurements with unprecedented spatial density over large areas, allow, among other things, the monitoring of the effects of fluid injection and extraction on surface deformation and the detection of active faults. Multi-interferogram approaches have been used at several geothermal sites in the US and abroad.

16

DUS II SOIL GAS SAMPLING AND AIR INJECTION TEST RESULTS  

Science Conference Proceedings (OSTI)

Soil vapor extraction (SVE) and air injection well testing was performed at the Dynamic Underground Stripping (DUS) site located near the M-Area Settling Basin (referred to as DUS II in this report). The objective of this testing was to determine the effectiveness of continued operation of these systems. Steam injection ended on September 19, 2009 and since this time the extraction operations have utilized residual heat that is present in the subsurface. The well testing campaign began on June 5, 2012 and was completed on June 25, 2012. Thirty-two (32) SVE wells were purged for 24 hours or longer using the active soil vapor extraction (ASVE) system at the DUS II site. During each test five or more soil gas samples were collected from each well and analyzed for target volatile organic compounds (VOCs). The DUS II site is divided into four parcels (see Figure 1) and soil gas sample results show the majority of residual VOC contamination remains in Parcel 1 with lesser amounts in the other three parcels. Several VOCs, including tetrachloroethylene (PCE) and trichloroethylene (TCE), were detected. PCE was the major VOC with lesser amounts of TCE. Most soil gas concentrations of PCE ranged from 0 to 60 ppmv with one well (VEW-22A) as high as 200 ppmv. Air sparging (AS) generally involves the injection of air into the aquifer through either vertical or horizontal wells. AS is coupled with SVE systems when contaminant recovery is necessary. While traditional air sparging (AS) is not a primary component of the DUS process, following the cessation of steam injection, eight (8) of the sixty-three (63) steam injection wells were used to inject air. These wells were previously used for hydrous pyrolysis oxidation (HPO) as part of the DUS process. Air sparging is different from the HPO operations in that the air was injected at a higher rate (20 to 50 scfm) versus HPO (1 to 2 scfm). . At the DUS II site the air injection wells were tested to determine if air sparging affected VOC soil gas concentrations during ASVE. Five (5) SVE wells that were located closest to the air injection wells were used as monitoring points during the air sparging tests. The air sparging tests lasted 48 hours. Soil gas sample results indicate that sparging did not affect VOC concentrations in four of the five sparging wells, while results from one test did show an increase in soil gas concentrations.

Noonkester, J.; Jackson, D.; Jones, W.; Hyde, W.; Kohn, J.; Walker, R.

2012-09-20T23:59:59.000Z

17

Analysis of injection tests in liquid-dominated geothermal reservoirs  

DOE Green Energy (OSTI)

The objective was to develop procedures for analyzing nonisothermal injection test data during the early phases of injection. In particular, methods for determining the permeability-thickness of the formation, skin factor of the well and tracking the movement of the thermal front have been developed. The techniques developed for interpreting injection pressure transients are closely akin to conventional groundwater and petroleum techniques for evaluating these parameters. The approach taken was to numerically simulate injection with a variety of temperatures, reservoir parameters and flowrates, in order to determine the characteristic responses due to nonisothermal injection. Two characteristic responses were identified: moving front dominated behavior and composite reservoir behavior. Analysis procedures for calculating the permeability-thickness of the formation and the skin factor of the well have been developed for each of these cases. In order to interpret the composite reservior behavior, a new concept has been developed; that of a ''fluid skin factor'', which accounts for the steady-state pressure buildup due to the region inside the thermal front. Based on this same concept, a procedure for tracking the movement of the thermal front has been established. The results also identify the dangers of not accounting the nonisothermal effects when analyzing injection test data. Both the permeability-thickness and skin factor of the well can be grossly miscalculated if the effects of the cold-region around the well are not taken into consideration. 47 refs., 30 figs., 14 tabs.

Benson, S.M.

1984-12-01T23:59:59.000Z

18

InSAR | Open Energy Information  

Open Energy Info (EERE)

InSAR InSAR Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: InSAR Details Activities (11) Areas (10) Regions (2) NEPA(0) Exploration Technique Information Exploration Group: Remote Sensing Techniques Exploration Sub Group: Active Sensors Parent Exploration Technique: Radar Information Provided by Technique Lithology: Stratigraphic/Structural: Geophysical Monitoring Hydrological: Can give indications about subsurface geothermal fluid flow Thermal: Dictionary.png InSAR: Interferometric Synthetic Aperture Radar (InSAR) is a remote sensing technique that can be used to accurately measure ground displacement. Other definitions:Wikipedia Reegle Introduction InSAR is a radar technique used in geodesy and remote sensing. This geodetic method uses two or more synthetic aperture radar (SAR) images to

19

Definition: InSAR | Open Energy Information  

Open Energy Info (EERE)

Definition Definition Edit with form History Facebook icon Twitter icon » Definition: InSAR Jump to: navigation, search Dictionary.png InSAR Interferometric Synthetic Aperture Radar (InSAR) is a remote sensing technique that can be used to accurately measure ground displacement.[1] View on Wikipedia Wikipedia Definition Interferometric synthetic aperture radar, abbreviated InSAR or IfSAR, is a radar technique used in geodesy and remote sensing. This geodetic method uses two or more synthetic aperture radar (SAR) images to generate maps of surface deformation or digital elevation, using differences in the phase of the waves returning to the satellite or aircraft. The technique can potentially measure centimetre-scale changes in deformation over spans of days to years. It has applications for

20

Scaleup tests and supporting research for the development of duct injection technology  

SciTech Connect

Gilbert Commonwealth, Southern Research Institute and the American Electric Power Service Corporation have embarked on a program to convert DOE's Duct Injection Test Facility located at the Muskingum River Power Plant of Ohio Power Company to test alternate duct injection technologies. The technologies to be tested include slurry sorbent injection of hydrated lime using dual fluid nozzles, or a rotary atomizer and pneumatic injection of hydrated lime, with flue gas humidification before or after sorbent injection. The literature review and analysis contained in this report is a part of the preparatory effort for the test program.

Gooch, J.P.; Dismukes, E.B.; Dahlin, R.S.; Faulkner, M.G. (Southern Research Inst., Birmingham, AL (United States)); Klett, M.G.; Buchanan, T.L.; Hunt, J.E. (Gilbert/Commonwealth, Inc., Reading, PA (United States))

1989-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "insar injectivity test" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Trona Injection Tests: Mirant Potomac River Station, Unit 1, November 12 to  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Trona Injection Tests: Mirant Potomac River Station, Unit 1, Trona Injection Tests: Mirant Potomac River Station, Unit 1, November 12 to December 23, 2005, Summary Report Trona Injection Tests: Mirant Potomac River Station, Unit 1, November 12 to December 23, 2005, Summary Report Docket No. EO-05-01: Trona injection tests were conducted at Mirant's Potomac River Station on Unit 1 between November 12 and December 23, 2005. The purpose of these tests was to determine the capability of dry injection of trona to achieve substantial SO2 removal from the stack discharge, and the determination of other operating impacts from he trona injection, if any. Trona Injection Tests: Mirant Potomac River Station, Unit 1, November 12 to December 23, 2005, Summary Report More Documents & Publications Special Environmental Analysis For Actions Taken under U.S. Department of

22

Single Well Injection Withdrawl Tracer Tests for Proppant ...  

A large question preventing optimal natural gas production from "hydrofracked" shales is how far proppants, injected to keep shale fractures open, ...

23

Injectivity Test At Fenton Hill Hdr Geothermal Area (Dash, Et Al., 1983) |  

Open Energy Info (EERE)

Injectivity Test At Fenton Hill Hdr Geothermal Area (Dash, Et Al., 1983) Injectivity Test At Fenton Hill Hdr Geothermal Area (Dash, Et Al., 1983) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Injectivity Test At Fenton Hill Hdr Geothermal Area (Dash, Et Al., 1983) Exploration Activity Details Location Fenton Hill Hdr Geothermal Area Exploration Technique Injectivity Test Activity Date Usefulness useful DOE-funding Unknown Notes Fenton Hill HDR site. References Z. V. Dash, H. D. Murphy, R. L. Aamodt, R. G. Aguilar, D. W. Brown, D. A. Counce, H. N. Fisher, C. O. Grigsby, H. Keppler, A. W. Laughlin, R. M. Potter, J. W. Tester, P. E. Trujillo Jr, G. Zyvoloski (1983) Hot Dry Rock Geothermal Reservoir Testing- 1978 To 1980 Retrieved from "http://en.openei.org/w/index.php?title=Injectivity_Test_At_Fenton_Hill_Hdr_Geothermal_Area_(Dash,_Et_Al.,_1983)&oldid=511316"

24

Injectivity Test At Fenton Hill Hdr Geothermal Area (Grigsby, Et Al., 1983)  

Open Energy Info (EERE)

Injectivity Test At Fenton Hill Hdr Geothermal Area (Grigsby, Et Al., 1983) Injectivity Test At Fenton Hill Hdr Geothermal Area (Grigsby, Et Al., 1983) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Injectivity Test At Fenton Hill Hdr Geothermal Area (Grigsby, Et Al., 1983) Exploration Activity Details Location Fenton Hill Hdr Geothermal Area Exploration Technique Injectivity Test Activity Date Usefulness not indicated DOE-funding Unknown References C. O. Grigsby, J. W. Tester, P. E. Trujillo, D. A. Counce, J. Abbott, C. E. Holley, L. A. Blatz (1983) Rock-Water Interactions In Hot Dry Rock Geothermal Systems- Field Investigations Of In Situ Geochemical Behavior Retrieved from "http://en.openei.org/w/index.php?title=Injectivity_Test_At_Fenton_Hill_Hdr_Geothermal_Area_(Grigsby,_Et_Al.,_1983)&oldid=511318

25

Resistivity measurements before and after injection Test 5 at Raft River  

Open Energy Info (EERE)

measurements before and after injection Test 5 at Raft River measurements before and after injection Test 5 at Raft River KGRA, Idaho. Final report Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Report: Resistivity measurements before and after injection Test 5 at Raft River KGRA, Idaho. Final report Details Activities (2) Areas (1) Regions (0) Abstract: Resistivity measurements were made prior to, and after an injection test at Raft River KGRA, Idaho. The objectives of the resistivity measurements were to determine if measureable changes could be observed and whether they could be used to infer the direction of fluid flow. Most of the apparent resistivity changes observed after the injection phase of Test 5 are smaller than the estimated standard deviation of the measurements. However, the contour map of the changes suggest an anomalous trend to the

26

TRACER STABILITY AND CHEMICAL CHANGES IN AN INJECTED GEOTHERMAL FLUID DURING INJECTION-BACKFLOW TESTING AT THE EAST MESA GEOTHERMAL FIELD  

DOE Green Energy (OSTI)

The stabilities of several tracers were tested under geothermal conditions while injection-backflow tests were conducted at East Mesa. The tracers I and Br were injected continuously while SCN (thiocyanate), B, and disodium fluorescein were each injected as a point source (slug). The tracers were shown to be stable, except where the high concentrations used during slug injection induced adsorption of the slug tracers. However, adsorption of the slug tracers appeared to ''armor'' the formation against adsorption during subsequent tests. Precipitation behavior of calcite and silica as well as Na/K shifts during injection are also discussed.

Adams, M.C.

1985-01-22T23:59:59.000Z

27

Injectivity Test At Reese River Area (Henkle & Ronne, 2008) | Open Energy  

Open Energy Info (EERE)

Reese River Area (Henkle & Ronne, Reese River Area (Henkle & Ronne, 2008) Exploration Activity Details Location Reese River Area Exploration Technique Injectivity Test Activity Date Usefulness not indicated DOE-funding Unknown Notes On March 22, 2007 a brief injectivity test was preformed after the slotted liner had been installed. Water was injected at flow rates of 6.3 l/s, 13 l/s and 19 l/s and the pressure and temperature was recorded down hole at a depth of 926 m. At the higher flow rate, the test was interrupted several times to repair leaks at the surface. From the recorded pressure an approximate injectivity index of 10 l/s/MPa was calculated. References William R. Henkle, Joel Ronne (2008) Phase 2 Reese River Geothermal Project Slim Well 56-4 Drilling And Testing Retrieved from

28

Scaleup tests and supporting research for the development of duct injection technology  

Science Conference Proceedings (OSTI)

DOE's Duct Injection Test Facility at Ohio Power Company's Muskingum River Plant was modified to enable performance of a comprehensive test program concerning duct injection of sorbents for SO[sub 2] control. Injection of slaked lime slurries and injection of dry calcium hydroxide powder with humidification were carried out under a variety of process conditions. Slaked lime slurry injection as found to be superior in both operational reliability and S0[sub 2] removal capability compared with dry hydrated lime injection with humidification. Calcium utilization of 50% was achieved with 50% S0[sub 2] removal at the ESP outlet with recycle of unreacted sorbent collected in the precipitatorhoppers. Electrostatic precipitator collection performance was found to be highly variable with sorbent injection, especially with close approach to saturation temperatures and high inlet mass loadings. Small-scale tests with a fabric filter in parallel with the precipitator indicated 5 to 10% more S0[sub 2] removal could be obtained across the fabric filter than the ESP for all test conditions. Over 95% S0[sub 2] removal was achieved with the fabric filter using a two stage cooling process in which the filter was cooled below the operating temperature ofthe duct spray dryer.

Felix, L.G.; Gooch, J.P.; Merritt, R.L. (Southern Research Inst., Birmingham, AL (United States)); Klett, M.G.; Demian, A.G.; Hunt, J.E. (Gilbert/Commonwealth, Inc., Reading, PA (United States))

1992-10-30T23:59:59.000Z

29

DOE Partnership Completes Successful CO2 Injection Test in the Mount Simon  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Partnership Completes Successful CO2 Injection Test in the Partnership Completes Successful CO2 Injection Test in the Mount Simon Sandstone DOE Partnership Completes Successful CO2 Injection Test in the Mount Simon Sandstone October 21, 2009 - 1:00pm Addthis Washington, DC - The Midwest Regional Carbon Sequestration Partnership (MRCSP), one of seven partnerships in the U.S. Department of Energy's Regional Carbon Sequestration Partnerships program, has successfully injected 1,000 metric tons of carbon dioxide (CO2) into the Mount Simon Sandstone, a deep saline formation that is widespread across much of the Midwest. Preliminary results indicate that the formation has good CO2 storage potential and could possibly serve as a repository for CO2 emissions captured from stationary sources in the region. Carbon capture and storage

30

Computerized data acquisition system for production, injection and interference tests  

DOE Green Energy (OSTI)

A computer-based system for collecting, processing, and analyzing pressure transient data has been developed. Primary components include downhole pressure sensors, linedrivers, a micro-computer, data storage disk, scanner, frequency counter, digital voltmeter, power supply, graphics plotter, and printer. In-field data processing and analysis greatly aid in handling the large volume of data that are collected during pressure transients tests, particularly the multiwell interference tests that are so important for characterizing and assessing geothermal reservoirs. In-field data processing provides the field engineer, on a real-time basis, with the information needed to make decisions regarding test parameters and duration. The system has been used on numerous occasions and has proved itself to be reliable under the harsh operating conditions that are usually encountered in the field. This paper describes the advantages of using this type of system for collecting data, the components and configuration of the system, and the software programs used to collect and process the data. Finally, two field applications are presented.

Benson, S.M.

1986-06-01T23:59:59.000Z

31

NETL: News Release - Frio Formation Test Well Injected With Carbon Dioxide  

NLE Websites -- All DOE Office Websites (Extended Search)

19, 2004 19, 2004 Frio Formation Test Well Injected With Carbon Dioxide Researchers Perform Small Scale, Short Term Carbon Sequestration Field Test HOUSTON, TX - In the first U.S. field test to investigate the ability of brine formations to store greenhouse gasses, researchers funded by the U.S. Department of Energy are closely monitoring 1,600 tons of carbon dioxide that were injected into a mile-deep well in Texas in October. The test is providing unique data to help investigators understand the viability of geologic sequestration as a means of reducing greenhouse gas emissions. The Frio Brine Pilot experimental site is 30 miles northeast of Houston, in the South Liberty oilfield. Researchers at the University of Texas at Austin's Bureau of Economic Geology drilled a 5,753 foot injection well earlier this year, and developed a nearby observation well to study the ability of the high-porosity Frio sandstone formation to store carbon dioxide.

32

Injectivity Test At Vale Hot Springs Area (Combs, Et Al., 1999) | Open  

Open Energy Info (EERE)

Vale Hot Springs Area (Combs, Et Vale Hot Springs Area (Combs, Et Al., 1999) Exploration Activity Details Location Vale Hot Springs Area Exploration Technique Injectivity Test Activity Date Usefulness useful DOE-funding Unknown Notes Analysis of the two injection tests performed at the exploration slimhole site during May, 1995 yielded estimates for the permeability-thickness product (transmissivity) kh of 0.25 and 0.23 Da-fi, based on pressure fall off after injection (see Section IV-a). Using the pressure buildup for the second test, a transmissivity of 0.610 Da-ft was estimated. These estimates are approximately an order of magnitude smaller than the kh values estimated for the nearby A-Alt well which was tested in 1994. References Jim Combs, John T. Finger, Colin Goranson, Charles E. Hockox Jr.,

33

Injectivity Test At Newberry Caldera Area (Combs, Et Al., 1999) | Open  

Open Energy Info (EERE)

Newberry Caldera Area (Combs, Et Al., 1999) Newberry Caldera Area (Combs, Et Al., 1999) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Injectivity Test At Newberry Caldera Area (Combs, Et Al., 1999) Exploration Activity Details Location Newberry Caldera Area Exploration Technique Injectivity Test Activity Date Usefulness useful DOE-funding Unknown Notes After circulating the mud out of the hole and replacing it with clear water, we attempted two injection tests; one into the open hole section (51 16'- 5360') below the HQ liner, and one into the annulus outside the uncemented part (2748' - -4800') of the liner. References Jim Combs, John T. Finger, Colin Goranson, Charles E. Hockox Jr., Ronald D. Jacobsen, Gene Polik (1999) Slimhole Handbook- Procedures And Recommendations For Slimhole Drilling And Testing In Geothermal Exploration

34

Scaleup tests and supporting research for the development of duct injection technology. Topical report No. 1, Literature review  

Science Conference Proceedings (OSTI)

Gilbert Commonwealth, Southern Research Institute and the American Electric Power Service Corporation have embarked on a program to convert DOE`s Duct Injection Test Facility located at the Muskingum River Power Plant of Ohio Power Company to test alternate duct injection technologies. The technologies to be tested include slurry sorbent injection of hydrated lime using dual fluid nozzles, or a rotary atomizer and pneumatic injection of hydrated lime, with flue gas humidification before or after sorbent injection. The literature review and analysis contained in this report is a part of the preparatory effort for the test program.

Gooch, J.P.; Dismukes, E.B.; Dahlin, R.S.; Faulkner, M.G. [Southern Research Inst., Birmingham, AL (United States); Klett, M.G.; Buchanan, T.L.; Hunt, J.E. [Gilbert/Commonwealth, Inc., Reading, PA (United States)

1989-05-01T23:59:59.000Z

35

Field Testing of Activated Carbon Injection Options for Mercury Control at TXU's Big Brown Station  

Science Conference Proceedings (OSTI)

The primary objective of the project was to evaluate the long-term feasibility of using activated carbon injection (ACI) options to effectively reduce mercury emissions from Texas electric generation plants in which a blend of lignite and subbituminous coal is fired. Field testing of ACI options was performed on one-quarter of Unit 2 at TXU's Big Brown Steam Electric Station. Unit 2 has a design output of 600 MW and burns a blend of 70% Texas Gulf Coast lignite and 30% subbituminous Powder River Basin coal. Big Brown employs a COHPAC configuration, i.e., high air-to-cloth baghouses following cold-side electrostatic precipitators (ESPs), for particulate control. When sorbent injection is added between the ESP and the baghouse, the combined technology is referred to as TOXECON{trademark} and is patented by the Electric Power Research Institute in the United States. Key benefits of the TOXECON configuration include better mass transfer characteristics of a fabric filter compared to an ESP for mercury capture and contamination of only a small percentage of the fly ash with AC. The field testing consisted of a baseline sampling period, a parametric screening of three sorbent injection options, and a month long test with a single mercury control technology. During the baseline sampling, native mercury removal was observed to be less than 10%. Parametric testing was conducted for three sorbent injection options: injection of standard AC alone; injection of an EERC sorbent enhancement additive, SEA4, with ACI; and injection of an EERC enhanced AC. Injection rates were determined for all of the options to achieve the minimum target of 55% mercury removal as well as for higher removals approaching 90%. Some of the higher injection rates were not sustainable because of increased differential pressure across the test baghouse module. After completion of the parametric testing, a month long test was conducted using the enhanced AC at a nominal rate of 1.5 lb/Macf. During the time that enhanced AC was injected, the average mercury removal for the month long test was approximately 74% across the test baghouse module. ACI was interrupted frequently during the month long test because the test baghouse module was bypassed frequently to relieve differential pressure. The high air-to-cloth ratio of operations at this unit results in significant differential pressure, and thus there was little operating margin before encountering differential pressure limits, especially at high loads. This limited the use of sorbent injection as the added material contributes to the overall differential pressure. This finding limits sustainable injection of AC without appropriate modifications to the plant or its operations. Handling and storage issues were observed for the TOXECON ash-AC mixture. Malfunctioning equipment led to baghouse dust hopper plugging, and storage of the stagnant material at flue gas temperatures resulted in self-heating and ignition of the AC in the ash. In the hoppers that worked properly, no such problems were reported. Economics of mercury control at Big Brown were estimated for as-tested scenarios and scenarios incorporating changes to allow sustainable operation. This project was funded under the U.S. Department of Energy National Energy Technology Laboratory project entitled 'Large-Scale Mercury Control Technology Field Testing Program--Phase II'.

John Pavlish; Jeffrey Thompson; Christopher Martin; Mark Musich; Lucinda Hamre

2009-01-07T23:59:59.000Z

36

Injectivity Test At Steamboat Springs Area (Combs, Et Al., 1999) | Open  

Open Energy Info (EERE)

Steamboat Springs Area (Combs, Et Steamboat Springs Area (Combs, Et Al., 1999) Exploration Activity Details Location Steamboat Springs Area Exploration Technique Injectivity Test Activity Date Usefulness not indicated DOE-funding Unknown Notes Part of the injection testing used downhole packers for isolating various zones and evaluating their permeability. By running the packers into the hole on N-rod ( 2.75"+K610 OD), the annulus was roughly the same cross-sectional area as the inside of the pipe. It was then possible to inject into either the zone above the packer or the one below, and compare the infectivity of those intervals. References Jim Combs, John T. Finger, Colin Goranson, Charles E. Hockox Jr., Ronald D. Jacobsen, Gene Polik (1999) Slimhole Handbook- Procedures And Recommendations For Slimhole Drilling And Testing In Geothermal Exploration

37

Field pilot tests for tertiary recovery using butane and propane injection  

SciTech Connect

This work describes a pilot project for tertiary recovery of liquid hydrocarbons through LPG injection in water-out sections of the Bolivar reservoir in La Pena Field, Santa Cruz, Boliva. The promising results obtained in the initial field miscibility tests, as well as the results from a mathematical model built to stimulate and evaluate the tertiary recovery project, directed subsequent work into a cyclic scheme for enhanced recovery. This scheme is explained and injection production data is presented. Field facilities built to handle both the injected LPG and the produced oil-LPG mixture are described. The oil/LPG ratio and the LPG recovered/injected fraction are the main factors measured in this to make further considerations for a full scale project.

Pacheco, E.F.; Garcia, A.I.

1981-01-01T23:59:59.000Z

38

Internal Technical Report, Hydrothermal Injection Program - East Mesa 1983-84 Test Data  

DOE Green Energy (OSTI)

This report presents a test data index and a data plots for a series of 12 drawdown and tracer injection-withdrawal tests in porous-media aquifers at the East Mesa Geothermal Field located in the Imperial Valley near El Centro, California. Test and instrumentation summaries are also provided. The first 10 of these tests were completed during July and August 1983. The remaining 2 tests were completed in February 1984, after a 6-month quiescent period, in which tracers were left in the reservoir. The test wells used were 56-30 and 56-19, with 38-30 supplying water for the injection phase and 52-29 used as a disposal well during the backflowing of the test wells. Six other wells in the surrounding area were measured periodically for possible hydrologic effects during testing. It is not the intent of this report to supply analyzed data, but to list the uninterpreted computer stored data available for analysis. The data have been examined only to the extent to ensure that they are reasonable and internally consistent. This data is stored on permanent files at the Idaho National Engineering Laboratory (INEL) Cyber Computer Complex. The main processors for this complex are located at the Computer Science Center (CSC) in Idaho Falls, Idaho. The Hydrothermal Injection Test program, funded by the Department of Energy, was a joint effort between EG and G Idaho, Inc., the University of Utah Research Institute (UURI) and Republic Geothermal, Inc. (RGI) of Santa Fe Springs, California.

Freiburger, R.M.

1984-09-01T23:59:59.000Z

39

Treatability Test Plan for 300 Area Uranium Stabilization through Polyphosphate Injection  

Science Conference Proceedings (OSTI)

The U.S. Department of Energy has initiated a study into possible options for stabilizing uranium at the 300 Area using polyphosphate injection. As part of this effort, PNNL will perform bench- and field-scale treatability testing designed to evaluate the efficacy of using polyphosphate injections to reduced uranium concentrations in the groundwater to meet drinking water standards (30 ug/L) in situ. This technology works by forming phosphate minerals (autunite and apatite) in the aquifer that directly sequester the existing aqueous uranium in autunite minerals and precipitates apatite minerals for sorption and long term treatment of uranium migrating into the treatment zone, thus reducing current and future aqueous uranium concentrations. Polyphosphate injection was selected for testing based on technology screening as part of the 300-FF-5 Phase III Feasibility Study for treatment of uranium in the 300-Area.

Vermeul, Vincent R.; Williams, Mark D.; Fritz, Brad G.; Mackley, Rob D.; Mendoza, Donaldo P.; Newcomer, Darrell R.; Rockhold, Mark L.; Williams, Bruce A.; Wellman, Dawn M.

2007-06-01T23:59:59.000Z

40

IN SITU DECOMMISSIONING SENSOR NETWORK, MESO-SCALE TEST BED - PHASE 3 FLUID INJECTION TEST SUMMARY REPORT  

SciTech Connect

The DOE Office of Environmental management (DOE EM) faces the challenge of decommissioning thousands of excess nuclear facilities, many of which are highly contaminated. A number of these excess facilities are massive and robust concrete structures that are suitable for isolating the contained contamination for hundreds of years, and a permanent decommissioning end state option for these facilities is in situ decommissioning (ISD). The ISD option is feasible for a limited, but meaningfull number of DOE contaminated facilities for which there is substantial incremental environmental, safety, and cost benefits versus alternate actions to demolish and excavate the entire facility and transport the rubble to a radioactive waste landfill. A general description of an ISD project encompasses an entombed facility; in some cases limited to the blow-grade portion of a facility. However, monitoring of the ISD structures is needed to demonstrate that the building retains its structural integrity and the contaminants remain entombed within the grout stabilization matrix. The DOE EM Office of Deactivation and Decommissioning and Facility Engineering (EM-13) Program Goal is to develop a monitoring system to demonstrate long-term performance of closed nuclear facilities using the ISD approach. The Savannah River National Laboratory (SRNL) has designed and implemented the In Situ Decommissioning Sensor Network, Meso-Scale Test Bed (ISDSN-MSTB) to address the feasibility of deploying a long-term monitoring system into an ISD closed nuclear facility. The ISDSN-MSTB goal is to demonstrate the feasibility of installing and operating a remote sensor network to assess cementitious material durability, moisture-fluid flow through the cementitious material, and resulting transport potential for contaminate mobility in a decommissioned closed nuclear facility. The original ISDSN-MSTB installation and remote sensor network operation was demonstrated in FY 2011-12 at the ISDSN-MSTB test cube located at the Florida International University Applied Research Center, Miami, FL (FIU-ARC). A follow-on fluid injection test was developed to detect fluid and ion migration in a cementitious material/grouted test cube using a limited number of existing embedded sensor systems. This In Situ Decommissioning Sensor Network, Meso-Scale Test Bed (ISDSN-MSTB) - Phase 3 Fluid Injection Test Summary Report summarizes the test implementation, acquired and processed data, and results from the activated embedded sensor systems used during the fluid injection test. The ISDSN-MSTB Phase 3 Fluid Injection Test was conducted from August 27 through September 6, 2013 at the FIU-ARC ISDSN-MSTB test cube. The fluid injection test activated a portion of the existing embedded sensor systems in the ISDSN-MSTB test cube: Electrical Resistivity Tomography-Thermocouple Sensor Arrays, Advance Tensiometer Sensors, and Fiber Loop Ringdown Optical Sensors. These embedded sensor systems were activated 15 months after initial placement. All sensor systems were remotely operated and data acquisition was completed through the established Sensor Remote Access System (SRAS) hosted on the DOE D&D Knowledge Management Information Tool (D&D DKM-IT) server. The ISDN Phase 3 Fluid Injection Test successfully demonstrated the feasibility of embedding sensor systems to assess moisture-fluid flow and resulting transport potential for contaminate mobility through a cementitious material/grout monolith. The ISDSN embedded sensor systems activated for the fluid injection test highlighted the robustness of the sensor systems and the importance of configuring systems in-depth (i.e., complementary sensors and measurements) to alleviate data acquisition gaps.

Serrato, M.

2013-09-27T23:59:59.000Z

Note: This page contains sample records for the topic "insar injectivity test" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Scaleup tests and supporting research for the development of duct injection technology  

Science Conference Proceedings (OSTI)

This Topical Report No. 2 is an interim report on the Duct Injection Test Facility being operated for the Department of Energy at Beverly, Ohio. Either dry calcium hydroxide or an aqueous slurry of calcium hydroxide (prepared by slaking quicklime) is injected into a slipstream of flue gas to achieve partial removal of SO{sub 2} from a coal-burning power station. Water injected with the slurry or injected separately from the dry sorbents cools the flue gas and increases the water vapor content of the gas. The addition of water, either in the slurry or in a separate spray, makes the extent of reaction between the sorbent and the SO{sub 2} more complete; the presumption is that water is effective in the liquid state, when it is able to wet the sorbent particles physically, and not especially effective in the vapor state. An electrostatic precipitator collects the combination of suspended solids (fly ash from the boiler and sorbent from the duct injection process). All of the operations are being carried out on the scale of approximately 50,000 acfm of flue gas.

Felix, L.G.; Dismukes, E.B.; Gooch, J.P. (Southern Research Inst., Birmingham, AL (United States)); Klett, M.G.; Demian, A.G. (Gilbert/Commonwealth, Inc., Reading, PA (United States))

1992-04-20T23:59:59.000Z

42

Modeling Single Well Injection-Withdrawal (SWIW) Tests for Characterization of Complex Fracture-Matrix Systems  

E-Print Network (OSTI)

not just near the injection well. Note that because thisConcentrations at the injection well increase during thethe fractures away from the injection well is fast, solutes

Cotte, F.P.

2012-01-01T23:59:59.000Z

43

Use of INSAR in surveillance and control of a large field project  

Science Conference Proceedings (OSTI)

In this paper, we introduce a new element of our [1] multilevel, integrated surveillance and control system: satellite Synthetic Aperture Radar interferometry (InSAR) images of oil field surface. In particular, we analyze five differential InSAR images of the Belridge Diatomite field, CA, between 11/98 and 12/99. The images have been reprocessed and normalized to obtain the ground surface displacement rate. In return, we have been able to calculate pixel-by-pixel the net subsidence of ground surface over the entire field area. The calculated annual subsidence volume of 19 million barrels is thought to be close to the subsidence at the top of the diatomite. We have also compared the 1999 rate of surface displacement from the satellite images with the surface monument triangulations between 1942 and 1997. We have found that the maximum rate of surface subsidence has been steadily increasing from -0.8 ft/year in 1988-97 to -1 ft/year in 1998-99. The respective rates of uplift of the field fringes also increased from 0.1 ft/year to 0.24 ft/year. In 1999, the observed subsidence rate exceeded by 4.5 million barrels the volumetric deficit of fluid injection.

Patzek, T.W.; Silin, D.B.

2000-06-01T23:59:59.000Z

44

Seismic monitoring of the June, 1988 Salton Sea Scientific Drilling Program flow/injection test  

DOE Green Energy (OSTI)

The purpose of the seismic monitoring project was to characterize in detail the micro-seismic activity related to the Salton Sea Scientific Drilling Program (SSSDP) flow-injection test in the Salton Sea Geothermal Field. Our goal was to determine if any sources of seismic energy related to the test were observable at the surface. We deployed our recording stations so that we could detect and locate both impulsive microearthquakes and continuous seismic noise energy. Our network, which was sensitive enough to be triggered by magnitude 0.0 or larger events, found no impulsive microearthquakes in the vicinity of the flow test in the 8 month period before the test and only one event during the flow test. This event has provided the opportunity to compare the detection and location capabilities of small networks and arrays in a geothermal environment. At present, we are carefully scanning all of the data that we collected during the flow test for evidence of anomalous seismic noise sources and for impulsive events smaller than the network detection threshold (magnitude 0.0). 8 refs., 4 figs.

Jarpe, S.P.; Kasameyer, P.W.; Hutchings, L.J.; Hauk, T.F.

1988-10-04T23:59:59.000Z

45

Test results of a steam injected gas turbine to increase power and thermal efficiency  

Science Conference Proceedings (OSTI)

The desire to increase both power and thermal efficiency of the gas turbine (Brayton cycle) engine has been pursued for a number of years and has involved many approaches. The use of steam in the cycle to improve performance has been proposed by various investigators. This was most recently proposed by International Power Technology, Inc. (IPT) and has been tested by Detroit Diesel Allison (DDA), Division of General Motors. This approach, identified as the Cheng dual-fluid cycle (Cheng/DFC), includes the generation of steam using heat from the exhaust, and injecting this steam into the engine combustion chamber. Test results on an Allison 501-KB engine have demonstrated that use of this concept will increase the thermal efficiency of the engine by 30% and the output power by 60% with no increase in turbine inlet temperature. These results will be discussed, as will the impact of steam rate, location of steam injection, turbine temperature, and engine operational characteristics on the performance of the Cheng/DFC.

Messerlie, R.L.; Tischler, A.O.

1983-08-01T23:59:59.000Z

46

Scaleup tests and supporting research for the development of duct injection technology. Final report, Task 4.5  

Science Conference Proceedings (OSTI)

DOE`s Duct Injection Test Facility at Ohio Power Company`s Muskingum River Plant was modified to enable performance of a comprehensive test program concerning duct injection of sorbents for SO{sub 2} control. Injection of slaked lime slurries and injection of dry calcium hydroxide powder with humidification were carried out under a variety of process conditions. Slaked lime slurry injection as found to be superior in both operational reliability and S0{sub 2} removal capability compared with dry hydrated lime injection with humidification. Calcium utilization of 50% was achieved with 50% S0{sub 2} removal at the ESP outlet with recycle of unreacted sorbent collected in the precipitatorhoppers. Electrostatic precipitator collection performance was found to be highly variable with sorbent injection, especially with close approach to saturation temperatures and high inlet mass loadings. Small-scale tests with a fabric filter in parallel with the precipitator indicated 5 to 10% more S0{sub 2} removal could be obtained across the fabric filter than the ESP for all test conditions. Over 95% S0{sub 2} removal was achieved with the fabric filter using a two stage cooling process in which the filter was cooled below the operating temperature ofthe duct spray dryer.

Felix, L.G.; Gooch, J.P.; Merritt, R.L. [Southern Research Inst., Birmingham, AL (United States); Klett, M.G.; Demian, A.G.; Hunt, J.E. [Gilbert/Commonwealth, Inc., Reading, PA (United States)

1992-10-30T23:59:59.000Z

47

Field Testing of Activated Carbon Injection Options for Mercury Control at TXU's Big Brown Station  

NLE Websites -- All DOE Office Websites (Extended Search)

Field TesTing oF AcTivATed cArbon Field TesTing oF AcTivATed cArbon injecTion opTions For Mercury conTrol AT TXu's big brown sTATion Background The 2005 Clean Air Mercury Rule will require significant reductions in mercury emissions from coal-fired power plants. Lignite coal is unique because of its highly variable ash content (rich in alkali and alkaline-earth elements), high moisture levels, low chlorine content, and high calcium content. Unique to Texas lignite coals are relatively high iron and selenium concentrations. When combusting Texas lignite coals, up to 80 percent of the mercury in the flue gas is present as elemental mercury, which is not readily captured by downstream pollution control devices. To better understand the factors that influence mercury control at units firing

48

InSAR At Medicine Lake Area (Poland, Et Al., 2006) | Open Energy...  

Open Energy Info (EERE)

Medicine Lake Area (Poland, Et Al., 2006) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: InSAR At Medicine Lake Area (Poland, Et Al., 2006)...

49

Modeling Single Well Injection-Withdrawal (SWIW) Tests for Characterization of Complex Fracture-Matrix Systems  

Science Conference Proceedings (OSTI)

The ability to reliably predict flow and transport in fractured porous rock is an essential condition for performance evaluation of geologic (underground) nuclear waste repositories. In this report, a suite of programs (TRIPOLY code) for calculating and analyzing flow and transport in two-dimensional fracture-matrix systems is used to model single-well injection-withdrawal (SWIW) tracer tests. The SWIW test, a tracer test using one well, is proposed as a useful means of collecting data for site characterization, as well as estimating parameters relevant to tracer diffusion and sorption. After some specific code adaptations, we numerically generated a complex fracture-matrix system for computation of steady-state flow and tracer advection and dispersion in the fracture network, along with solute exchange processes between the fractures and the porous matrix. We then conducted simulations for a hypothetical but workable SWIW test design and completed parameter sensitivity studies on three physical parameters of the rock matrix - namely porosity, diffusion coefficient, and retardation coefficient - in order to investigate their impact on the fracture-matrix solute exchange process. Hydraulic fracturing, or hydrofracking, is also modeled in this study, in two different ways: (1) by increasing the hydraulic aperture for flow in existing fractures and (2) by adding a new set of fractures to the field. The results of all these different tests are analyzed by studying the population of matrix blocks, the tracer spatial distribution, and the breakthrough curves (BTCs) obtained, while performing mass-balance checks and being careful to avoid some numerical mistakes that could occur. This study clearly demonstrates the importance of matrix effects in the solute transport process, with the sensitivity studies illustrating the increased importance of the matrix in providing a retardation mechanism for radionuclides as matrix porosity, diffusion coefficient, or retardation coefficient increase. Interestingly, model results before and after hydrofracking are insensitive to adding more fractures, while slightly more sensitive to aperture increase, making SWIW tests a possible means of discriminating between these two potential hydrofracking effects. Finally, we investigate the possibility of inferring relevant information regarding the fracture-matrix system physical parameters from the BTCs obtained during SWIW testing.

Cotte, F.P.; Doughty, C.; Birkholzer, J.

2010-11-01T23:59:59.000Z

50

Testing of a new aftertreatment system for lean burn direct injected gasoline engines.  

E-Print Network (OSTI)

??A gasoline direct injected engine operating under lean conditions can offer a reduction in fuel consumption and a reduction of CO2 emissions but meanwhile suffer (more)

Thulin, Andeas

2011-01-01T23:59:59.000Z

51

Thermal single-well injection-withdrawal tracer tests for determining fracture-matrix heat transfer area  

SciTech Connect

Single-well injection-withdrawal (SWIW) tracer tests involve injection of traced fluid and subsequent tracer recovery from the same well, usually with some quiescent time between the injection and withdrawal periods. SWIW are insensitive to variations in advective processes that arise from formation heterogeneities, because upon withdrawal, fluid parcels tend to retrace the paths taken during injection. However, SWIW are sensitive to diffusive processes, such as diffusive exchange of conservative or reactive solutes between fractures and rock matrix. This paper focuses on SWIW tests in which temperature itself is used as a tracer. Numerical simulations demonstrate the sensitivity of temperature returns to fracture-matrix interaction. We consider thermal SWIW response to the two primary reservoir improvements targeted with stimulation, (1) making additional fractures accessible to injected fluids, and (2) increasing the aperture and permeability of pre-existing fractures. It is found that temperature returns in SWIW tests are insensitive to (2), while providing a strong signal of more rapid temperature recovery during the withdrawal phase for (1).

Pruess, K.; Doughty, C.

2010-01-15T23:59:59.000Z

52

INVESTIGATION OF CRUSTAL MOTION IN THE TIEN SHAN USING INSAR  

SciTech Connect

The northern Tien Shan of Central Asia is an area of active mid-continent deformation. Although far from a plate boundary, this region has experienced 5 earthquakes larger than magnitude 7 in the past century and includes one event that may as be as large as Mw 8.0. Previous studies based on GPS measurements indicate on the order of 23 mm/yr of shortening across the entire Tien Shan and up to 15 mm/year in the northern Tien Shan (Figure 1). The seismic moment release rate appears comparable with the geodetic measured slip, at least to first order, suggesting that geodetic rates can be considered a proxy for accumulation rates of stress for seismic hazard estimation. Interferometric synthetic aperture radar may provide a means to make detailed spatial measurements and hence in identifying block boundaries and assisting in seismic hazard. Therefore, we hoped to define block boundaries by direct measurement and by identifying and resolving earthquake slip. Due to political instability in Kyrgzystan, the existing seismic network has not performed as well as required to precisely determine earthquake hypocenters in remote areas and hence InSAR is highly useful. In this paper we present the result of three earthquake studies and show that InSAR is useful for refining locations of teleseismically located earthquakes. ALOS PALSAR data is used to investigate crustal motion in the Tien Shan mountains of Central Asia. As part of the work, considerable software development was undertaken to process PALSAR data. This software has been made freely available. Two damaging earthquakes have been imaged in the Tien Shan and the locations provided by ALOS InSAR have helped to refine seismological velocity models. A third earthquake south of Kyrgyzstan was also imaged. The use of InSAR data and especially L band is therefore very useful in providing groundtruth for earthquake locations.

Mellors, R J

2011-02-25T23:59:59.000Z

53

Analytical modeling of a fracture-injection/falloff sequence and the development of a refracture-candidate diagnostic test  

E-Print Network (OSTI)

Fracture-injection/falloff sequences are routinely used as pre-frac well tests to estimate reservoir pressure and transmissibility, but the current interpretation methods are limited to analyzing specific and very small portions of the pressure falloff data. To remove the current limitations, new analytical fractureinjection/ falloff models are developed that account for fracture propagation, fracture closure, and after fracture closure diffusion. A fracture-injection/falloff differs from a conventional injection/falloff sequence in that pressure during the injection is sufficient to initiate and propagate a hydraulic fracture. By considering fracture propagation as time-dependent storage, three new models are presented for a fractureinjection/ falloff sequence in a well in an infinite slab reservoir with a single vertical fracture created during the injection and with variable fracture and wellbore storage as follows: ? Equivalent propagating-fracture and before-fracture-closure storage with constant after-fractureclosure storage. ? Time-dependent propagating-fracture storage, constant before-closure storage, and constant afterclosure storage. ? Time-dependent propagating-fracture storage, constant before-closure storage with linear flow from the fracture, and constant wellbore storage and skin with after-closure radial flow. When a fracture-injection can be considered as occurring instantaneously, limiting-case solutions of the new fracture-injection/falloff models suggest the observed pressure difference can be integrated to generate an equivalent pressure difference if the rate were constant. Consequently, a fractureinjection/ falloff sequence can be analyzed with constant-rate, variable-storage type curves. The new fracture-injection/falloff theory is also extended to allow for a fracture-injection in a reservoir containing an existing conductive hydraulic fracture. The new multiple-fracture fracture-injection/falloff model forms the basis of a new refracture-candidate diagnostic test that uses characteristic variable-storage behavior to qualitatively diagnose a pre-existing fracture retaining residual width and to determine if a preexisting fracture is damaged. A quantitative analysis methodology is also proposed that uses a new pressure-transient solution for a well in an infinite-slab reservoir producing through multiple arbitrarilyoriented finite- or infinite-conductivity fractures.

Craig, David Paul

2005-05-01T23:59:59.000Z

54

Pilot plant testing of Illinois coal for blast furnace injection. Technical report, September 1--November 30, 1994  

Science Conference Proceedings (OSTI)

The purpose of this study is to evaluate the combustion of Illinois coal in the blast furnace injection process in a new and unique pilot plant test facility. This investigation is significant to the use of Illinois coal in that the limited research to date suggests that coals of low fluidity and moderate to high sulfur and chlorine contents are suitable feedstocks for blast furnace injection. This study is unique in that it is the first North American effort to directly determine the nature of the combustion of coal injected into a blast furnace. It is intended to complete the study already underway with the Armco and Inland steel companies and to demonstrate quantitatively the suitability of both the Herrin No. 6 and Springfield No. 5 coals for blast furnace injection. The main feature of the current work is the testing of Illinois coals at CANMET`s (Canadian Centre for Mineral and Energy Technology) pilot plant coal combustion facility. This facility simulates blowpipe-tuyere conditions in an operating blast furnace, including blast temperature (900 C), flow pattern (hot velocity 200 m/s), geometry, gas composition, coal injection velocity (34 m/s) and residence time (20 ms). The facility is fully instrumented to measure air flow rate, air temperature, temperature in the reactor, wall temperature, preheater coil temperature and flue gas analysis. During this quarter a sample of the Herrin No. 6 coal (IBCSP 112) was delivered to the CANMET facility and testing is scheduled for the week of 11 December 1994. Also at this time, all of the IBCSP samples are being evaluated for blast furnace injection using the CANMET computer model.

Crelling, J.C. [Southern Illinois Univ., Carbondale, IL (United States). Dept. of Geology

1994-12-31T23:59:59.000Z

55

Scaleup tests and supporting research for the development of duct injection technology. Topical report No. 2, Task 3.1: Evaluation of system performance, Duct Injection Test Facility, Muskingum River Power Plant, Beverly, Ohio  

Science Conference Proceedings (OSTI)

This Topical Report No. 2 is an interim report on the Duct Injection Test Facility being operated for the Department of Energy at Beverly, Ohio. Either dry calcium hydroxide or an aqueous slurry of calcium hydroxide (prepared by slaking quicklime) is injected into a slipstream of flue gas to achieve partial removal of SO{sub 2} from a coal-burning power station. Water injected with the slurry or injected separately from the dry sorbents cools the flue gas and increases the water vapor content of the gas. The addition of water, either in the slurry or in a separate spray, makes the extent of reaction between the sorbent and the SO{sub 2} more complete; the presumption is that water is effective in the liquid state, when it is able to wet the sorbent particles physically, and not especially effective in the vapor state. An electrostatic precipitator collects the combination of suspended solids (fly ash from the boiler and sorbent from the duct injection process). All of the operations are being carried out on the scale of approximately 50,000 acfm of flue gas.

Felix, L.G.; Dismukes, E.B.; Gooch, J.P. [Southern Research Inst., Birmingham, AL (United States); Klett, M.G.; Demian, A.G. [Gilbert/Commonwealth, Inc., Reading, PA (United States)

1992-04-20T23:59:59.000Z

56

Analysis of PS InSAR Monitoring Result of Beijing Subsidence  

Science Conference Proceedings (OSTI)

Urban subsidence causes more concerns in China recently. PS InSAR technique is a very useful method for surface deformation detection. We selected Beijing as study area. Being the capital of China, Beijing suffered from ground subsidence for a long time. ... Keywords: urban subsidence, PS InSAR, COSMO-SkyMed, high resolution

Dong Jiang; Mario Costantini; Tingwu Chen; Zikuan Zhou; Chunqing Ge; Jiangbing Cao

2012-10-01T23:59:59.000Z

57

Surface deformation analysis over a hydrocarbon reservoir using InSAR with ALOS-PALSAR data  

E-Print Network (OSTI)

InSAR has been developed to estimate the temporal change on the surface of Earth by combining multiple SAR images acquired over the same area at different times. In the last two decades, in addition to conventional InSAR, ...

?ahin, Sedar Cihan

2013-01-01T23:59:59.000Z

58

100-NR-2 Apatite Treatability Test FY09 Status: High Concentration Calcium-Citrate-Phosphate Solution Injection for In Situ Strontium-90 Immobilization  

SciTech Connect

100-NR-2 Apatite Treatability Test FY09 Status: High Concentration Calcium-Citrate-Phosphate Solution Injection for In Situ Strontium-90 Immobilization INTERIM LETTER REPORT

Vermeul, Vincent R.; Fritz, Brad G.; Fruchter, Jonathan S.; Szecsody, James E.; Williams, Mark D.

2009-12-16T23:59:59.000Z

59

InSAR At Dixie Valley Geothermal Field Area (Laney, 2005) | Open Energy  

Open Energy Info (EERE)

Laney, 2005) Laney, 2005) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: InSAR At Dixie Valley Geothermal Field Area (Laney, 2005) Exploration Activity Details Location Dixie Valley Geothermal Field Area Exploration Technique InSAR Activity Date Usefulness useful DOE-funding Unknown Notes Localized Strain as a Discriminator of Hidden Geothermal Systems, Vasco and Foxall, 2005. Recent work has focused on (1) collaborating with Alessandro Ferretti to use Permanent Scatterer (PS) InSAR data to infer strain at depth, (2) working with Lane Johnson to develop a dynamic faulting model, and (3) acquiring InSAR data for the region surrounding the Dixie Valley fault zone in collaboration with Dr. William Foxall of LLNL. The InSAR data have been processed and an initial interpretation of the results is

60

Forecast of thermal-hydrological conditions and air injection test results of the single heater test at Yucca Mountain  

E-Print Network (OSTI)

ESF Single Heater Test, Sandia National Laboratories Letterthe Single Heater Test by Sandia (Sobolik et al. , 1996).the Single Heater Test by Sandia (Sobolik etal. , 1996). cap

Birkholzer, J.T.

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "insar injectivity test" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

InSAR At Redfield Campus Area (Oppliger, Et Al., 2008) | Open Energy  

Open Energy Info (EERE)

Campus Area (Oppliger, Et Al., 2008) Campus Area (Oppliger, Et Al., 2008) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: InSAR At Redfield Campus Area (Oppliger, Et Al., 2008) Exploration Activity Details Location Redfield Campus Area Exploration Technique InSAR Activity Date Usefulness useful DOE-funding Unknown Notes Along with the GIS, an InSAR deformation study was conducted from a suite of previously created interferograms from 1993-2005. Jet Propulsion Laboratory's Repeat Orbit Interferometry processing software Package (ROI_PAC) was used in the formation of approximately 35 interferograms considered for use in this study. All InSAR pairs were systematically screened to determine those suitable for further processing based on signal-to-noise and data integrity around the Redfield campus and Steamboat

62

InSAR At Brady Hot Springs Area (Laney, 2005) | Open Energy Information  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon » InSAR At Brady Hot Springs Area (Laney, 2005) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: InSAR At Brady Hot Springs Area (Laney, 2005) Exploration Activity Details Location Brady Hot Springs Area Exploration Technique InSAR Activity Date Usefulness not indicated DOE-funding Unknown Notes InSAR Ground Displacement Analysis, Gary Oppliger and Mark Coolbaugh. This project supports increased utilization of geothermal resources in the Western United States by developing basic measurements and interpretations that will assist reservoir management and expansion at Bradys, Desert Peak

63

InSAR At Coso Geothermal Area (2000) | Open Energy Information  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon » InSAR At Coso Geothermal Area (2000) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: InSAR At Coso Geothermal Area (2000) Exploration Activity Details Location Coso Geothermal Area Exploration Technique InSAR Activity Date 2000 Usefulness useful DOE-funding Unknown Exploration Basis To determine ground subsidence using satellite radar interferometry Notes Interferometric synthetic aperture radar (InSAR) data collected in the Coso geothermal area, eastern California, during 1993-1999 indicate ground subsidence over a approximately 50 km 2 region that approximately coincides

64

InSAR At Desert Peak Area (Laney, 2005) | Open Energy Information  

Open Energy Info (EERE)

InSAR At Desert Peak Area (Laney, 2005) InSAR At Desert Peak Area (Laney, 2005) Exploration Activity Details Location Desert Peak Area Exploration Technique InSAR Activity Date Usefulness not indicated DOE-funding Unknown Notes InSAR Ground Displacement Analysis, Gary Oppliger and Mark Coolbaugh. This project supports increased utilization of geothermal resources in the Western United States by developing basic measurements and interpretations that will assist reservoir management and expansion at Bradys, Desert Peak and the Desert Peak EGS study area (80 km NE of Reno, Nevada) and will serve as a technology template for other geothermal fields. Raw format European Space Agency (ESA) ERS 1/2 satellite synthetic Aperture Radar (SAR) radar scenes acquired from 1992 through 2002 are being processed to

65

Scaleup tests and supporting research for the development of duct injection technology: Topical report No. 7, Task 4. 1: Testing of first generation mathematical model predictions; Topical report No. 8, Task 4. 2: Testing of second generation mathematical model predictions, Duct Injection Test Facility, Muskingum River Power Plant, Beverly, OH  

Science Conference Proceedings (OSTI)

Gilbert/Commonwealth (G/C) and Southern Research Institute have completed a project under DOE sponsorship entitled Scaleup Tests and Supporting Research for the Development of Duct Injection Technology''. The project included extensive modifications to DOE's Duct Injection Test Facility (DITF) located at the Muskingum River Plant of Ohio Power Company. A comprehensive test program was performed at the facility to evaluate So[sub 2] removal and overall process operability with duct injection of slaked lime slurries and dry injection of calcium hydroxide powder with humidification. Detailed results from the project are presented in the following reports: Topical Report No. 1 -- Literature Review; Topical Report No. 2 -- Evaluation of System Performance; Topical Report No. 3 -- Scale-Up Testing; Advanced Configurations Process Controls; Failure Modes; and Waste characterization. Project Final Report. The purposes of this report are: (1) to satisfy a contractual requirement for a separate topical report concerning the subject of mathematical model validation, and (2) to briefly describe the status of the model development and validation effort.

Felix, L.G.; Gooch, J.P. (Southern Research Inst., Birmingham, AL (United States)); Klett, M.G.; Demian, A.G. (Gilbert/Commonwealth, Inc., Reading, PA (United States))

1992-08-01T23:59:59.000Z

66

Scaleup tests and supporting research for the development of duct injection technology: Topical report No. 7, Task 4.1: Testing of first generation mathematical model predictions; Topical report No. 8, Task 4.2: Testing of second generation mathematical model predictions, Duct Injection Test Facility, Muskingum River Power Plant, Beverly, OH  

Science Conference Proceedings (OSTI)

Gilbert/Commonwealth (G/C) and Southern Research Institute have completed a project under DOE sponsorship entitled ``Scaleup Tests and Supporting Research for the Development of Duct Injection Technology``. The project included extensive modifications to DOE`s Duct Injection Test Facility (DITF) located at the Muskingum River Plant of Ohio Power Company. A comprehensive test program was performed at the facility to evaluate So{sub 2} removal and overall process operability with duct injection of slaked lime slurries and dry injection of calcium hydroxide powder with humidification. Detailed results from the project are presented in the following reports: Topical Report No. 1 -- Literature Review; Topical Report No. 2 -- Evaluation of System Performance; Topical Report No. 3 -- Scale-Up Testing; Advanced Configurations Process Controls; Failure Modes; and Waste characterization. Project Final Report. The purposes of this report are: (1) to satisfy a contractual requirement for a separate topical report concerning the subject of mathematical model validation, and (2) to briefly describe the status of the model development and validation effort.

Felix, L.G.; Gooch, J.P. [Southern Research Inst., Birmingham, AL (United States); Klett, M.G.; Demian, A.G. [Gilbert/Commonwealth, Inc., Reading, PA (United States)

1992-08-01T23:59:59.000Z

67

Use of data obtained from core tests in the design and operation of spent brine injection wells in geopressured or geothermal systems  

DOE Green Energy (OSTI)

The effects of formation characteristics on injection well performance are reviewed. Use of data acquired from cores taken from injection horizons to predict injectivity is described. And methods for utilizing data from bench scale testing of brine and core samples to optimize injection well design are presented. Currently available methods and equipment provide data which enable the optimum design of injection wells through analysis of cores taken from injection zones. These methods also provide a means of identifying and correcting well injection problems. Methods described in this report are: bulk density measurement; porosity measurement; pore size distribution analysis; permeability measurement; formation grain size distribution analysis; core description (lithology) and composition; amount, type and distribution of clays and shales; connate water analysis; consolidatability of friable reservoir rocks; grain and pore characterization by scanning electron microscopy; grain and pore characterization by thin section analysis; permeability damage and enhancement tests; distribution of water-borne particles in porous media; and reservoir matrix acidizing effectiveness. The precise methods of obtaining this information are described, and their use in the engineering of injection wells is illustrated by examples, where applicable. (MHR)

Jorda, R.M.

1980-03-01T23:59:59.000Z

68

Safety Design Strategy for the Advanced Test Reactor Emergency Firewater Injection System Replacement Project  

Science Conference Proceedings (OSTI)

In accordance with the requirements of U.S. Department of Energy (DOE) Order 413.3B, Program and Project Management for the Acquisition of Capital Assets, safety must be integrated into the design process for new or major modifications to DOE Hazard Category 1, 2, and 3 nuclear facilities. The intended purpose of this requirement involves the handling of hazardous materials, both radiological and chemical, in a way that provides adequate protection to the public, workers, and the environment. Requirements provided in DOE Order 413.3B and DOE Order 420.1B, Facility Safety, and the expectations of DOE-STD-1189-2008, Integration of Safety into the Design Process, provide for identification of hazards early in the project and use of an integrated team approach to design safety into the facility. This safety design strategy provides the basic safety-in-design principles and concepts that will be used for the Advanced Test Reactor Reliability Sustainment Project. While this project does not introduce new hazards to the ATR, it has the potential for significant impacts to safety-related systems, structures, and components that are credited in the ATR safety basis and are being replaced. Thus the project has been determined to meet the definition of a major modification and is being managed accordingly.

Noel Duckwitz

2011-06-01T23:59:59.000Z

69

Beam injection into RHIC  

SciTech Connect

During the RHIC sextant test in January 1997 beam was injected into a sixth of one of the rings for the first time. The authors describe the injection zone and its bottlenecks. They report on the commissioning of the injection system, on beam based measurements of the kickers and the application program to steer the beam.

Fischer, W.; Hahn, H.; MacKay, W.W.; Satogata, T.; Tsoupas, N.; Zhang, W.

1997-07-01T23:59:59.000Z

70

A model comparison initiative for a CO2 injection field test: An introduction to Sim-SEQ  

E-Print Network (OSTI)

IPCC Special Report on Carbon Dioxide Capture and Storage,buildup during supercritical carbon dioxide injection from asequestration of carbon dioxide, Environmental Science &

Mukhopadhyay, S.

2013-01-01T23:59:59.000Z

71

Southeast Geyers Cooperative Tracer Evaluation and Testing Program for the Purpose of Estimating The Efficiency of Injection  

DOE Green Energy (OSTI)

The Southeast Geysers Cooperative Tracer Evaluation Program has been a joint project located in the SE part of the Geysers geothermal field, in Lake and Sonoma Counties, California. A new generation of environmentally benign vapor-phase tracers has been used to estimate the varying degrees to which injectate is being recovered following the significant increase of injected volumes within the Southeast Geysers.

J.L. (Bill) Smith

2001-02-12T23:59:59.000Z

72

DOE/NETL's phase II mercury control technology field testing program: preliminary economic analysis of activated carbon injection  

Science Conference Proceedings (OSTI)

Based on results of field testing conducted by the U.S. Department of Energy's National Energy Technology Laboratory (DOE/NETL), this article provides preliminary costs for mercury control via conventional activated carbon injection (ACI), brominated ACI, and conventional ACI coupled with the application of a sorbent enhancement additive (SEA) to coal prior to combustion. The economic analyses are reported on a plant-specific basis in terms of the cost required to achieve low (50%), mid (70%), and high (90%) levels of mercury removal 'above and beyond' the baseline mercury removal achieved by existing emission control equipment. In other words, the levels of mercury control are directly attributable to ACI. Mercury control costs via ACI have been amortized on a current dollar basis. Using a 20-year book life, levelized costs for the incremental increase in cost of electricity (COE), expressed in mills per kilowatt-hour (mills/kWh), and the incremental cost of mercury control, expressed in dollars per pound of mercury removed ($/lb Hg removed), have been calculated for each level of ACI mercury control. For this analysis, the increase in COE varied from 0.14 mills/kWh to 3.92 mills/kWh. Meanwhile, the incremental cost of mercury control ranged from $3810/lb Hg removed to $166 000/lb Hg removed. 13 refs., 4 figs., 3 tabs.

Andrew P. Jones; Jeffrey W. Hoffmann; Dennis N. Smith; Thomas J. Feeley III; James T. Murphy [National Energy Technology Laboratory, Pittsburgh, PA (United States)

2007-02-15T23:59:59.000Z

73

Proof of concept testing of an integrated dry injection system for SO{sub 2}/NO{sub x} control. Final report  

Science Conference Proceedings (OSTI)

The integrated Dry Injection Process (IDIP) consists of combustion modification using low NO{sub x} burners to reduce NO{sub x} emissions, dry injection of hydrated line at economizer temperatures for primary capture of SO{sub 2}, dry injection of a commercial grade sodium bicarbonate at the air heater exit for additional SO{sub 2} and NO{sub x} removal, and humidification for precipitator conditioning. IDIP offers the potential for simultaneously achieving 90% SO{sub 2} removal, and 65% NO{sub x} removal from a high sulfur flue gas. The process is well suited for new or retrofit applications since it can be incorporated within existing economizer and downstream ductwork. Subscale tests were performed in order to identify the best calcium and sodium sorbents. These tests involved the injection of calcium hydroxide and sodium sorbents at various points of the flue gas system downstream of a 0.25 MM BTU/hr. coal fired combustor, and the gas residence times, cooling rates and temperatures were comparable to those found for full-scale utility boilers. These tests verified that a high surface area hydrated lime provides maximum sorbent utilization and identified an alcohol-water hydrated lime as yielding the highest surface area and the best SO{sub 2} removal capability. The tests also identified sodium bicarbonate to be somewhat more effective than sodium sesquicarbonate for SO{sub 2} removal. The proof of concept demonstration was conducted on the large combustor at the Riley Stoker Research Facility in Worcester, MA. When economically compared to conventional limestone slurry scrubbing on a 300 MW plant, the dry injection process shows lower capital cost but higher operating cost. Hydrated lime injection can be less costly than limestone scrubbing when two or more of the following conditions exist: plant is small (less than 100MW); yearly operating hours are small (less than 3000); and the remaining plant lifetime is small (less than 10 years).

Helfritch, D.J.; Bortz, S.J. [Research-Cottrell, Inc., Somerville, NJ (United States); Beittel, R. [Riley Stoker Corp., Worcester, MA (United States)

1994-03-01T23:59:59.000Z

74

Monitoring and characterizing natural hazards with satellite InSAR imagery *, Jixian Zhangb  

E-Print Network (OSTI)

-temporal RADARSAT-1 and ERS backscattering signatures of coastal wetlands at Southeastern Louisiana. Photogrammetric. Monitoring dynamic water-level changes in wetlands improves hydrological modeling predictions-level changes in wetlands Both L-band and C-band InSAR imagery can be used to measure water-level changes

75

A model comparison initiative for a CO2 injection field test: An introduction to Sim-SEQ  

E-Print Network (OSTI)

of a multiphase wateroil CO 2 system using a waterCO 2et al. , 2011) in a depleted oil and gas reservoir under COwith CO 2 injected into the oil-bearing zone in the northern

Mukhopadhyay, S.

2013-01-01T23:59:59.000Z

76

Corrective Action Plan for Corrective Action Unit 335: Area 6 Injection Well and Drain Pit Nevada Test Site, Nevada  

SciTech Connect

This Corrective Action Plan (CAP) has been prepared for Corrective Action Unit (CAU) 335, Area 6 Injection Well and Drain Pit, in accordance with the Federal Facility Agreement and Consent Order (FFACO) (1996). This CAP provides the methodology for implementing the approved corrective action alternative as listed in the Corrective Action Decision Document (CADD). However, there is one modification to the selected alternative. Due to the large area that would require fencing, it is proposed that instead of fencing, an appropriate number of warning signs attached to tee posts be used to delineate the use restriction area. CAU 335 is located in Area 6 of the Nevada Test Site (NTS) which is approximately 105 kilometers (km) (65 miles [mi]) northwest of Las Vegas, Nevada. CAU 335 is located in the Area 6 Well 3 Yard approximately 39 km (24 mi) north of Mercury, on the Mercury Highway and several hundred feet (ft) west along Road 6-06. CAU 335 consists of the following three Corrective Action Sites (CASs): CAS 06-20-01, Drums, Oil Waste, Spill; CAS 06-20-02, 20-inch Cased Hole; CAS 06-23-03, Drain Pit. The site history for CAU 335 is provided in the Corrective Action Investigation Plan (DOE/NV, 2000). Briefly, CAS 06-20-01, was used for storing material that was pumped out of CAS 06-20-02 and placed into four 208-liter (L) (55-gall [gal]) drums. The drums were taken to the NTS Area 5 Hazardous Waste Accumulation Site in 1991. CAS 06-20-01 will be closed with no further action required. Any spills associated with CAS 06-20-01 are addressed and considered part of CAS 06-20-02. CAS 06-20-02 was used for disposal of used motor oil, wastewater, and debris for an undetermined amount of time. In 1991, the casing was emptied of its contents, excavated, and backfilled. CAS 06-23-03 was used as a depository for effluent waste from truck-washing activities from 1960-1991.

K. B. Campbell

2002-10-01T23:59:59.000Z

77

Closure Report for Corrective Action Unit 335: Area 6 Injection Well and Drain Pit, Nevada Test Site, Nevada  

SciTech Connect

This Closure Report documents the activities undertaken to close Corrective Action Unit 335: Area 6 Injection Well and Drain Pit, according to the Federal Facility Agreement and Consent Order. Corrective Action Unit 335 was closed in accordance with the Nevada Division of Environmental Protection-approved Corrective Action Plan for Corrective Action Unit 335.

U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office; Bechtel Nevada

2003-06-01T23:59:59.000Z

78

InSAR At Salton Sea Area (Eneva And Adams, 2010) | Open Energy Information  

Open Energy Info (EERE)

Eneva And Adams, 2010) Eneva And Adams, 2010) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: InSAR At Salton Sea Area (Eneva And Adams, 2010) Exploration Activity Details Location Salton Sea Area Exploration Technique InSAR Activity Date Usefulness useful regional reconnaissance DOE-funding Unknown References Mariana Eneva, David Adams (2010) Modeling Of Surface Deformation From Satellite Radar Interferometry In The Salton Sea Geothermal Field, California Retrieved from "http://en.openei.org/w/index.php?title=InSAR_At_Salton_Sea_Area_(Eneva_And_Adams,_2010)&oldid=400447" Category: Exploration Activities What links here Related changes Special pages Printable version Permanent link Browse properties 429 Throttled (bot load) Error 429 Throttled (bot load)

79

Injecting Carbon Dioxide into Unconventional Storage Reservoirs...  

NLE Websites -- All DOE Office Websites (Extended Search)

will also be investigated with a targeted CO 2 injection test into a depleted shale gas well. Different reservoir models will be used before, during, and after injection...

80

THE RHIC INJECTION SYSTEM.  

SciTech Connect

The RHIC injection system has to transport beam from the AGS-to-RHIC transfer line onto the closed orbits of the RHIC Blue and Yellow rings. This task can be divided into three problems. First, the beam has to be injected into either ring. Second, once injected the beam needs to be transported around the ring for one turn. Third, the orbit must be closed and coherent beam oscillations around the closed orbit should be minimized. We describe our solutions for these problems and report on system tests conducted during the RHIC Sextant test performed in 1997. The system will be fully commissioned in 1999.

FISCHER,W.; GLENN,J.W.; MACKAY,W.W.; PTITSIN,V.; ROBINSON,T.G.; TSOUPAS,N.

1999-03-29T23:59:59.000Z

Note: This page contains sample records for the topic "insar injectivity test" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Thermal single-well injection-withdrawal tracer tests for determining fracture-matrix heat transfer area  

E-Print Network (OSTI)

Testing for Estimating Heat Transfer Area in FracturedFRACTURE-MATRIX HEAT TRANSFER AREA Karsten Pruess andimprove the flow and heat transfer characteristics of the

Pruess, K.

2011-01-01T23:59:59.000Z

82

Corrective Action Decision Document for Corrective Action Unit 322: Areas 1 and 3 Release Sites and Injection Wells Nevada Test Site, Nevada, Rev. No. 0  

SciTech Connect

This Corrective Action Decision Document has been prepared for Corrective Action Unit (CAU) 322, Areas 1 and 3 Release Sites and Injection Wells, Nevada Test Site, Nevada, in accordance with the ''Federal Facility Agreement and Consent Order'' (1996). Corrective Action Unit 322 is comprised of the following corrective action sites (CASs): (1) 01-25-01 - AST Release Site; (2) 03-25-03 - Mud Plant and AST Diesel Release; and (3) 03-20-05 - Injection Wells and BOP Shop. The purpose of this Corrective Action Decision Document is to identify and provide the rationale for the recommendation of a corrective action alternative for each CAS within CAU 322. Corrective action investigation activities were performed from April 2004 through September 2004, as set forth in the Corrective Action Investigation Plan. The purposes of the activities as defined during the data quality objectives process were: (1) Determine if contaminants of concern (COCs) are present; (2) If COCs are present, determine their nature and extent; and (3) Provide sufficient information and data to recommend appropriate corrective actions for the CASs. Analytes detected during the corrective action investigation were evaluated against appropriate preliminary action levels to identify contaminants of concern for each corrective action site. Radiological field measurements were compared to unrestricted release criteria. Assessment of the data generated from investigation activities revealed the following: (1) CAS 01-25-01 contains an AST berm contaminated with total petroleum hydrocarbons (TPH) diesel-range organics (DRO). (2) CAS 03-25-03 includes two distinct areas: Area A where no contamination remains from a potential spill associated with an AST, and Area B where TPH-DRO contamination associated with various activities at the mud plant was identified. The Area B contamination was found at various locations and depths. (3) CAS 03-25-03 Area B contains TPH-DRO contamination at various locations and depths in the area associated with the Mud Plant. (4) CAS 03-20-05 contains TPH-DRO, metals, and radiological contamination within the injection well casing soil and TPH-DRO contamination at the depth coincidental with the bottom of the injection well sump. Based on the evaluation of analytical data from the corrective action investigation, review of future and current operations in Areas 1 and 3 of the Nevada Test Site, and the detailed and comparative analysis of the potential corrective action alternatives, the following corrective actions are recommended for the Corrective Action Unit 322 CASs. Closure in Place with Administrative Controls is the preferred corrective action for the following CASs: (1) CAS 01-25-01, removal of TPH-DRO contamination would pose a significant safety hazard due to the site location. (2) CAS 03-25-03 No contamination remains at Area A (AST Berm); and thus, no further action is the preferred alternative at this part of the CAS. However at Area B, TPH-DRO contamination is varied in concentration and location and the footprint of the CAS is large, removal of contaminated ''pockets'' would be laborious and cost prohibitive. The plutonium-239 surface contamination identified at CAS 03-25-03 Area B has been removed and drummed as a best management practice. (3) CAS 03-20-05, TPH-DRO, metals, and radiological contamination are present in the injection well casing soils. Recommend corrective action includes removal of the liquid in the injection well sump (approximately 3 feet (ft) of liquid at 60 ft below ground surface), grouting the sump, and the area within the injection well casing.

Robert Boehlecke

2004-12-01T23:59:59.000Z

83

Interim Report: 100-NR-2 Apatite Treatability Test: Low Concentration Calcium Citrate-Phosphate Solution Injection for In Situ Strontium-90 Immobilization  

SciTech Connect

Following an evaluation of potential Sr-90 treatment technologies and their applicability under 100-NR-2 hydrogeologic conditions, U.S. Department of Energy, Fluor Hanford, Inc., Pacific Northwest National Laboratory, and the Washington Department of Ecology agreed that the long-term strategy for groundwater remediation at 100-N Area will include apatite sequestration as the primary treatment, followed by a secondary treatment if necessary (most likely phytoremediation). Since then, the agencies have worked together to agree on which apatite sequestration technology has the greatest chance of reducing Sr-90 flux to the river at a reasonable cost. In July 2005, aqueous injection, (i.e., the introduction of apatite-forming chemicals into the subsurface) was endorsed as the interim remedy and selected for field testing. Studies are in progress to assess the efficacy of in situ apatite formation by aqueous solution injection to address both the vadose zone and the shallow aquifer along the 300 ft of shoreline where Sr-90 concentrations are highest. This report describes the field testing of the shallow aquifer treatment.

Williams, Mark D.; Fritz, Brad G.; Mendoza, Donaldo P.; Rockhold, Mark L.; Thorne, Paul D.; Xie, YuLong; Bjornstad, Bruce N.; Mackley, Rob D.; Newcomer, Darrell R.; Szecsody, James E.; Vermeul, Vincent R.

2008-07-11T23:59:59.000Z

84

Corrective Action Decision Document/Closure Report for Corrective Action Unit 546: Injection Well and Surface Releases Nevada Test Site, Nevada, Revision 0  

SciTech Connect

This Corrective Action Decision Document/Closure Report has been prepared for Corrective Action Unit 546, Injection Well and Surface Releases, at the Nevada Test Site, Nevada, in accordance with the Federal Facility Agreement and Consent Order (FFACO, 1996; as amended February 2008). Corrective Action Unit (CAU) 546 is comprised of two corrective action sites (CASs): 06-23-02, U-6a/Russet Testing Area 09-20-01, Injection Well The purpose of this Corrective Action Decision Document/Closure Report is to provide justification and documentation supporting the recommendation for closure of CAU 546. To achieve this, corrective action investigation (CAI) activities were performed from May 5 through May 28, 2008, as set forth in the Corrective Action Investigation Plan for Corrective Action Unit 546: Injection Well and Surface Releases, Nevada Test Site, Nevada (NNSA/NSO, 2008). The purpose of the CAI was to fulfill the following data needs as defined during the data quality objective (DQO) process: Determine whether a contaminant of concern is present at a given CAS. Determine whether sufficient information is available to evaluate potential corrective action alternatives at each CAS. The CAU 546 dataset from the investigation results was evaluated based on the data quality indicator parameters. This evaluation demonstrated the quality and acceptability of the dataset for use in fulfilling the DQO data needs. Because DQO data needs were met, and corrective actions have been implemented, it has been determined that no further corrective action (based on risk to human receptors) is necessary for the CAU 546 CASs. The U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office provides the following recommendations: No further corrective actions are needed for CAU 546 CASs. No Corrective Action Plan is required. A Notice of Completion to the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office is requested from the Nevada Division of Environmental Protection for closure of CAU 546. Corrective Action Unit 546 should be moved from Appendix III to Appendix IV of the Federal Facility Agreement and Consent Order. Analytes detected during the CAI were evaluated against final action levels established in this document. No analytes were detected at concentrations exceeding final action levels. However, contaminants of concern were presumed to be present in the subsurface soil at CAS 09-20-01. Therefore, the corrective action of close in place was selected as the preferred alternative for this CAS. Potential source material was removed from CAS 06-23-02; therefore, the corrective action of clean closure was selected as the preferred alternative at this CAS.

Alfred Wickline

2008-12-01T23:59:59.000Z

85

Corrective Action Investigation Plan for Corrective Action Unit 219: Septic Systems and Injection Wells, Nevada Test Site, Nevada, Rev. No.: 0  

Science Conference Proceedings (OSTI)

The Corrective Action Investigation Plan for Corrective Action Unit 219, Septic Systems and Injection Wells, has been developed in accordance with the ''Federal Facility Agreement and Consent Order'' (1996) that was agreed to by the State of Nevada, the U.S. Department of Energy, and the U.S. Department of Defense. The purpose of the investigation is to ensure that adequate data are collected to provide sufficient and reliable information to identify, evaluate, and select technically viable corrective actions. Corrective Action Unit 219 is located in Areas 3, 16, and 23 of the Nevada Test Site, which is 65 miles northwest of Las Vegas, Nevada. Corrective Action Unit 219 is comprised of the six Corrective Action Sites (CASs) listed below: (1) 03-11-01, Steam Pipes and Asbestos Tiles; (2) 16-04-01, Septic Tanks (3); (3) 16-04-02, Distribution Box; (4) 16-04-03, Sewer Pipes; (5) 23-20-01, DNA Motor Pool Sewage and Waste System; and (6) 23-20-02, Injection Well. These sites are being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives. Additional information will be obtained by conducting a corrective action investigation prior to evaluating corrective action alternatives and selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible evaluation of viable corrective action alternatives that will be presented in the Corrective Action Decision Document.

David A. Strand

2005-01-01T23:59:59.000Z

86

InSAR observations of aseismic slip associated with an earthquake swarm in the Columbia River flood basalts  

E-Print Network (OSTI)

's Hanford Site. Data from the seismic network along with interferometric synthetic aperture radar (In of the swarm. By modeling the InSAR deformation data we constructed a model that consists of a shallow thrust detected nearly 40 years ago in and around the Hanford Nuclear Site located in the eastern YFB [Pitt, 1971

87

Corrective Action Decision Document for Corrective Action Unit 322: Areas 1 and 3 Release Sites and Injection Wells Nevada Test Site, Nevada, Revision 0 with ROTC 1  

Science Conference Proceedings (OSTI)

This Corrective Action Decision Document has been prepared for Corrective Action Unit (CAU) 322, Areas 1 and 3 Release Sites and Injection Wells, Nevada Test Site, Nevada, in accordance with the ''Federal Facility Agreement and Consent Order'' (1996). Corrective Action Unit 322 is comprised of the following corrective action sites (CASs): (1) 01-25-01 - AST Release Site; (2) 03-25-03 - Mud Plant and AST Diesel Release; and (3) 03-20-05 - Injection Wells and BOP Shop. The purpose of this Corrective Action Decision Document is to identify and provide the rationale for the recommendation of a corrective action alternative for each CAS within CAU 322. Corrective action investigation activities were performed from April 2004 through September 2004, as set forth in the Corrective Action Investigation Plan. The purposes of the activities as defined during the data quality objectives process were: (1) Determine if contaminants of concern (COCs) are present; (2) If COCs are present, determine their nature and extent; and (3) Provide sufficient information and data to recommend appropriate corrective actions for the CASs. Analytes detected during the corrective action investigation were evaluated against appropriate preliminary action levels to identify contaminants of concern for each corrective action site. Radiological field measurements were compared to unrestricted release criteria. Assessment of the data generated from investigation activities revealed the following: (1) CAS 01-25-01 contains an AST berm contaminated with total petroleum hydrocarbons (TPH) diesel-range organics (DRO). (2) CAS 03-25-03 includes two distinct areas: Area A where no contamination remains from a potential spill associated with an AST, and Area B where TPH-DRO contamination associated with various activities at the mud plant was identified. The Area B contamination was found at various locations and depths. (3) CAS 03-25-03 Area B contains TPH-DRO contamination at various locations and depths in the area associated with the Mud Plant. (4) CAS 03-20-05 contains TPH-DRO, metals, and radiological contamination within the injection well casing soil and TPH-DRO contamination at the depth coincidental with the bottom of the injection well sump. Based on the evaluation of analytical data from the corrective action investigation, review of future and current operations in Areas 1 and 3 of the Nevada Test Site, and the detailed and comparative analysis of the potential corrective action alternatives, the following corrective actions are recommended for the Corrective Action Unit 322 CASs. Closure in Place with Administrative Controls is the preferred corrective action for the following CASs: (1) CAS 01-25-01, removal of TPH-DRO contamination would pose a significant safety hazard due to the site location. (2) CAS 03-25-03 No contamination remains at Area A (AST Berm); and thus, no further action is the preferred alternative at this part of the CAS. However at Area B, TPH-DRO contamination is varied in concentration and location and the footprint of the CAS is large, removal of contaminated ''pockets'' would be laborious and cost prohibitive. The plutonium-239 surface contamination identified at CAS 03-25-03 Area B has been removed and drummed as a best management practice. (3) CAS 03-20-05, TPH-DRO, metals, and radiological contamination are present in the injection well casing soils. Recommend corrective action includes removal of the liquid in the injection well sump (approximately 3 feet (ft) of liquid at 60 ft below ground surface), grouting the sump, and the area within the injection well casing. The plutonium-239 surface contamination identified at CAS 03-20-05 has been removed and drummed as a best management practice and will be disposed of as low-level radioactive waste. It is recommended that the liquids be removed from the holding tank wells and the sumps of the two outer holding tanks within the BOP Shop, and the sumps be grouted, and the holding tanks filled in to the BOP Shop floor surface. The preferred corrective action alternatives were ev

Boehlecke, Robert

2004-12-01T23:59:59.000Z

88

Coupled reservoir-geomechanical analysis of CO2 injection and ground deformations at In Salah, Algeria  

SciTech Connect

In Salah Gas Project in Algeria has been injecting 0.5-1 million tonnes CO{sub 2} per year over the past five years into a water-filled strata at a depth of about 1,800 to 1,900 m. Unlike most CO{sub 2} storage sites, the permeability of the storage formation is relatively low and comparatively thin with a thickness of about 20 m. To ensure adequate CO{sub 2} flow-rates across the low-permeability sand-face, the In Salah Gas Project decided to use long-reach (about 1 to 1.5 km) horizontal injection wells. In an ongoing research project we use field data and coupled reservoir-geomechanical numerical modeling to assess the effectiveness of this approach and to investigate monitoring techniques to evaluate the performance of a CO{sub 2}-injection operation in relatively low permeability formations. Among the field data used are ground surface deformations evaluated from recently acquired satellite-based inferrometry (InSAR). The InSAR data shows a surface uplift on the order of 5 mm per year above active CO{sub 2} injection wells and the uplift pattern extends several km from the injection wells. In this paper we use the observed surface uplift to constrain our coupled reservoir-geomechanical model and conduct sensitivity studies to investigate potential causes and mechanisms of the observed uplift. The results of our analysis indicates that most of the observed uplift magnitude can be explained by pressure-induced, poro-elastic expansion of the 20 m thick injection zone, but there could also be a significant contribution from pressure-induced deformations within a 100 m thick zone of shaly sands immediately above the injection zone.

Rutqvist, J.; Vasco, D.W.; Myer, L.

2009-11-01T23:59:59.000Z

89

Corrective Action Decision Document/Closure Report for Corrective Action Unit 219: Septic Systems and Injection Wells, Nevada Test Site, Nevada, Rev. No.: 0  

SciTech Connect

This Corrective Action Decision Document/Closure Report has been prepared for Corrective Action Unit (CAU) 219, Septic Systems and Injection Wells, in Areas 3, 16, and 23 of the Nevada Test Site, Nevada, in accordance with the ''Federal Facility Agreement and Consent Order'' (1996). Corrective Action Unit 219 is comprised of the following corrective action sites (CASs): (1) 03-11-01, Steam Pipes and Asbestos Tiles; (2) 16-04-01, Septic Tanks (3); (3) 16-04-02, Distribution Box; (4) 16-04-03, Sewer Pipes; (5) 23-20-01, DNA Motor Pool Sewage and Waste System; and (6) 23-20-02, Injection Well. The purpose of this Corrective Action Decision Document/Closure Report is to provide justification and documentation supporting the recommendation for closure of CAU 219 with no further corrective action beyond the application of a use restriction at CASs 16-04-01, 16-04-02, and 16-04-03. To achieve this, corrective action investigation (CAI) activities were performed from June 20 through October 12, 2005, as set forth in the CAU 219 Corrective Action Investigation Plan and Record of Technical Change No. 1. A best management practice was implemented at CASs 16-04-01, 16-04-02, and 16-04-03, and corrective action was performed at CAS 23-20-01 between January and April 2006. In addition, a use restriction will be applied to CASs 16-04-01, 16-04-02, and 16-04-03 to provide additional protection to Nevada Test Site personnel. The purpose of the CAI was to fulfill the following data needs as defined during the data quality objective (DQO) process: (1) Determine whether contaminants of concern (COCs) are present. (2) If COCs are present, determine their nature and extent. (3) Provide sufficient information and data to complete appropriate corrective actions. The CAU 219 dataset from the investigation results was evaluated based on the data quality indicator parameters. This evaluation demonstrated the quality and acceptability of the dataset for use in fulfilling the DQO data needs. Analytes detected during the CAI were evaluated against final action levels (FALs) established in this document. A Tier 2 evaluation was conducted, and a FAL of 185,000 micrograms per kilogram was calculated for chlordane at CASs 16-04-01, 16-04-02, and 16-04-03 based on an occasional use area exposure scenario. This evaluation of chlordane based on the Tier 2 FAL determined that no FALs were exceeded. Therefore, the DQO data needs were met, and it was determined that no corrective action (based on risk to human receptors) is necessary for the site. The following contaminants were determined to be present at concentrations exceeding their corresponding FALs: (1) The surface soil surrounding the main concrete pad at CAS 23-20-01 contained Aroclor-1254, Aroclor-1260, and chlordane above the FALs. This soil, along with the COCs, was subsequently removed at CAS 23-20-01. (2) The sludge in the concrete box of the catch basin at the large concrete pad at CAS 23-20-01 contained lead and benzo(a)pyrene above the FALs. This contamination was limited to the sludge in the concrete box of the catch basin and did not migrate to the subsurface features beneath it. The contaminated and the concrete box of the catch basin were subsequently recovered at CAS 23-20-01.

David Strand

2006-05-01T23:59:59.000Z

90

Slit injection device  

DOE Patents (OSTI)

A laser cavity electron beam injection device provided with a single elongated slit window for passing a suitably shaped electron beam and means for varying the current density of the injected electron beam.

Alger, Terry W. (Livermore, CA); Schlitt, Leland G. (Livermore, CA); Bradley, Laird P. (Livermore, CA)

1976-06-15T23:59:59.000Z

91

Rich catalytic injection  

SciTech Connect

A gas turbine engine includes a compressor, a rich catalytic injector, a combustor, and a turbine. The rich catalytic injector includes a rich catalytic device, a mixing zone, and an injection assembly. The injection assembly provides an interface between the mixing zone and the combustor. The injection assembly can inject diffusion fuel into the combustor, provides flame aerodynamic stabilization in the combustor, and may include an ignition device.

Veninger, Albert (Coventry, CT)

2008-12-30T23:59:59.000Z

92

Geothermal injection monitoring project  

DOE Green Energy (OSTI)

Background information is provided on the geothermal brine injection problem and each of the project tasks is outlined in detail. These tasks are: evaluation of methods of monitoring the movement of injected fluid, preparation for an eventual field experiment, and a review of groundwater regulations and injection programs. (MHR)

Younker, L.

1981-04-01T23:59:59.000Z

93

NETL: News Release - CO2 Injection Begins in Illinois  

NLE Websites -- All DOE Office Websites (Extended Search)

21, 2011 CO2 Injection Begins in Illinois Large-Scale Test to Inject 1 Million Metric Tons of Carbon Dioxide in Saline Formation Washington, D.C. - The Midwest Geological...

94

Addendum to the Closure Report for Corrective Action Unit 322: Areas 1 & 3 Release Sites and Injection Wells Nevada Test Site, Nevada, Revision 0  

SciTech Connect

This document constitutes an addendum to the June 2006, Closure Report for Corrective Action Unit 322: Areas 1 & 3 Release Sites and Injection Wells as described in the document Recommendations and Justifications for Modifications for Use Restrictions Established under the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office Federal Facility Agreement and Consent Order (UR Modification document) dated February 2008. The UR Modification document was approved by NDEP on February 26, 2008. The approval of the UR Modification document constituted approval of each of the recommended UR modifications. In conformance with the UR Modification document, this addendum consists of: This cover page that refers the reader to the UR Modification document for additional information The cover and signature pages of the UR Modification document The NDEP approval letter The corresponding section of the UR Modification document This addendum provides the documentation justifying the cancellation of the URs for: CAS 01-25-01, AST Release CAS 03-25-03, Mud Plant AST Diesel Release These URs were established as part of Federal Facility Agreement and Consent Order (FFACO) corrective actions and were based on the presence of contaminants at concentrations greater than the action levels established at the time of the initial investigation (FFACO, 1996; as amended August 2006). Since these URs were established, practices and procedures relating to the implementation of risk-based corrective actions (RBCA) have changed. Therefore, these URs were re-evaluated against the current RBCA criteria as defined in the Industrial Sites Project Establishment of Final Action Levels (NNSA/NSO, 2006c). This re-evaluation consisted of comparing the original data (used to define the need for the URs) to risk-based final action levels (FALs) developed using the current Industrial Sites RBCA process. The re-evaluation resulted in a recommendation to remove these URs because contamination is not present at these sites above the risk-based FALs. Requirements for inspecting and maintaining these URs will be canceled, and the postings and signage at each site will be removed. Fencing and posting may be present at these sites that are unrelated to the FFACO URs such as for radiological control purposes as required by the NV/YMP Radiological Control Manual (NNSA/NSO, 2004f). This modification will not affect or modify any non-FFACO requirements for fencing, posting, or monitoring at these sites.

Lynn Kidman

2008-10-01T23:59:59.000Z

95

Addendum to the Closure Report for Corrective Action Unit 335: Area 6 Injection Well and Drain Pit Nevada Test Site, Nevada, Revison 0  

SciTech Connect

This document constitutes an addendum to the June 2003, Closure Report for Corrective Action Unit 335: Area 6 Injection Well and Drain Pit as described in the document Recommendations and Justifications for Modifications for Use Restrictions Established under the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office Federal Facility Agreement and Consent Order (UR Modification document) dated February 2008. The UR Modification document was approved by NDEP on February 26, 2008. The approval of the UR Modification document constituted approval of each of the recommended UR modifications. In conformance with the UR Modification document, this addendum consists of: This cover page that refers the reader to the UR Modification document for additional information The cover and signature pages of the UR Modification document The NDEP approval letter The corresponding section of the UR Modification document This addendum provides the documentation justifying the cancellation of the URs for: CAS 06-20-02, 20-inch Cased Hole CAS 06-23-03, Drain Pit These URs were established as part of Federal Facility Agreement and Consent Order (FFACO) corrective actions and were based on the presence of contaminants at concentrations greater than the action levels established at the time of the initial investigation (FFACO, 1996; as amended August 2006). Since these URs were established, practices and procedures relating to the implementation of risk-based corrective actions (RBCA) have changed. Therefore, these URs were re-evaluated against the current RBCA criteria as defined in the Industrial Sites Project Establishment of Final Action Levels (NNSA/NSO, 2006c). This re-evaluation consisted of comparing the original data (used to define the need for the URs) to risk-based final action levels (FALs) developed using the current Industrial Sites RBCA process. The re-evaluation resulted in a recommendation to remove these URs because contamination is not present at these sites above the risk-based FALs. Requirements for inspecting and maintaining these URs will be canceled, and the postings and signage at each site will be removed. Fencing and posting may be present at these sites that are unrelated to the FFACO URs such as for radiological control purposes as required by the NV/YMP Radiological Control Manual (NNSA/NSO, 2004f). This modification will not affect or modify any non-FFACO requirements for fencing, posting, or monitoring at these sites.

Lynn Kidman

2008-10-01T23:59:59.000Z

96

Corrective Action Investigation Plan for Corrective Action Unit 322: Areas 1 and 3 Release Sites and Injection Wells, Nevada Test Site, Nevada: Revision 0, Including Record of Technical Change No. 1  

SciTech Connect

This Corrective Action Investigation Plan contains the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office's approach to collect the data necessary to evaluate corrective action alternatives (CAAs) appropriate for the closure of Corrective Action Unit (CAU) 322, Areas 1 and 3 Release Sites and Injection Wells, Nevada Test Site, Nevada, under the Federal Facility Agreement and Consent Order. Corrective Action Unit 322 consists of three Corrective Action Sites (CASs): 01-25-01, AST Release (Area 1); 03-25-03, Mud Plant AST Diesel Release (Area 3); 03-20-05, Injection Wells (Area 3). Corrective Action Unit 322 is being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives. The investigation of three CASs in CAU 322 will determine if hazardous and/or radioactive constituents are present at concentrations and locations that could potentially pose a threat to human health and the environment. The results of this field investigation will support a defensible evaluation of corrective action alternatives in the corrective action decision document.

U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office

2003-07-16T23:59:59.000Z

97

Intradermal needle-free powdered drug injection  

E-Print Network (OSTI)

This thesis presents a new method for needle-free powdered drug injection. The design, construction, and testing of a bench-top helium-powered device capable of delivering powder to controllable depths within the dermis ...

Liu, John (John Hsiao-Yung)

2012-01-01T23:59:59.000Z

98

Design considerations for pump-and-treat remediation based on characterization of industrial injection wells: Lessons learned from the groundwater interim action at the test area north of the Idaho National Engineering Laboratory  

SciTech Connect

The Idaho National Engineering Laboratory (INEL) is a 2,305 km{sup 2} (890 mi{sup 2}) Federal Facility operated by the U.S. Department of Energy, Idaho Operations Office. The Test Area North (TAN) complex is located approximately 80 km (50 mi) northwest of Idaho Falls in the northern portion of the HSTEL and extends over an area of approximately 30 km{sup 2} (12 mi{sup 2}). The Technical Support Facility (TSF) is centrally located within TAN and consists of several experimental and support facilities for conducting research and development activities on nuclear reactor performance. Operations at TAN were initiated in the early 1950s to support the U.S. Air Force aircraft nuclear propulsion project and have continued over the years with various experimental and testing facilities. The TSF-05 Injection well was used from 1953 to 1972 to dispose of TAN liquid wastes in the fractured basalt of the Snake River Plain Aquifer. Trichloroethylene (TCE) was first identified as a groundwater contaminant in 1987 when it was found in the TAN drinking water above acceptable levels. The TAN Groundwater Interim Action at the INEL was intended to provide both interim containment and clean-up of contaminated groundwater resulting from the 40-year old injection well, TSF-05. The primary decontamination objective of the Groundwater Treatment Facility (GWTF) is to remove volatile organic compounds, primarily TCE. A pump-and-treat technology using air stripping, carbon adsorption, and resin ion exchange for strontium-90 ({sup 90}Sr) was selected in the Operable Unit 1-07A Groundwater Interim Action Record of Decision. Operations started on February 16, 1994 and activities were suspended on January 23, 1995 due to the inability to meet Remedial Action Objectives (RAOs).

Cotten, G.B.

1995-11-01T23:59:59.000Z

99

100-NR-2 Apatite Treatability Test: High-Concentration Calcium-Citrate-Phosphate Solution Injection for In Situ Strontium-90 Immobilization  

SciTech Connect

Following an evaluation of potential strontium-90 (90Sr) treatment technologies and their applicability under 100-NR-2 hydrogeologic conditions, the U.S. Department of Energy (DOE), Fluor Hanford, Inc. (now CH2M Hill Plateau Remediation Company [CHPRC]), Pacific Northwest National Laboratory, and the Washington State Department of Ecology agreed that the long-term strategy for groundwater remediation at the 100-N Area should include apatite as the primary treatment technology. This agreement was based on results from an evaluation of remedial alternatives that identified the apatite permeable reactive barrier (PRB) technology as the approach showing the greatest promise for reducing 90Sr flux to the Columbia River at a reasonable cost. This letter report documents work completed to date on development of a high-concentration amendment formulation and initial field-scale testing of this amendment solution.

Vermeul, Vincent R.; Fritz, Brad G.; Fruchter, Jonathan S.; Szecsody, James E.; Williams, Mark D.

2010-09-01T23:59:59.000Z

100

Geysers injection modeling  

DOE Green Energy (OSTI)

Our research is concerned with mathematical modeling techniques for engineering design and optimization of water injection in vapor-dominated systems. The emphasis in the project has been on the understanding of physical processes and mechanisms during injection, applications to field problems, and on transfer of numerical simulation capabilities to the geothermal community. This overview summarizes recent work on modeling injection interference in the Southeast Geysers, and on improving the description of two-phase flow processes in heterogeneous media.

Pruess, K.

1994-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "insar injectivity test" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Underground Injection Control (Louisiana)  

Energy.gov (U.S. Department of Energy (DOE))

The Injection and Mining Division (IMD) has the responsibility of implementing two major federal environmental programs which were statutorily charged to the Office of Conservation: the Underground...

102

Application of Gaseous Sphere Injection Method for Modeling Under-expanded H2 Injection  

DOE Green Energy (OSTI)

A methodology for modeling gaseous injection has been refined and applied to recent experimental data from the literature. This approach uses a discrete phase analogy to handle gaseous injection, allowing for addition of gaseous injection to a CFD grid without needing to resolve the injector nozzle. This paper focuses on model testing to provide the basis for simulation of hydrogen direct injected internal combustion engines. The model has been updated to be more applicable to full engine simulations, and shows good agreement with experiments for jet penetration and time-dependent axial mass fraction, while available radial mass fraction data is less well predicted.

Whitesides, R; Hessel, R P; Flowers, D L; Aceves, S M

2010-12-03T23:59:59.000Z

103

TEST  

Science Conference Proceedings (OSTI)

This is an abstract. TEST Lorem ipsum dolor sit amet, consectetur adipiscing elit. Cras lacinia dui et est venenatis lacinia. Vestibulum lacus dolor, adipiscing id mattis sit amet, ultricies sed purus. Nulla consectetur aliquet feugiat. Maecenas ips

104

INJECTION AND THERMAL BREAKTHROUGH IN FRACTURED GEOTHERMAL RESERVOIRS  

E-Print Network (OSTI)

and Pruess, K. , Analysis of injection testing of geothermalreservoirs: Geothermal Resoures Council, Vol. 4. , (into a fractured geothermal reservoir: Transactions, Vol. 4,

Bodvarsson, Gudmundur S.

2012-01-01T23:59:59.000Z

105

Interpretation of self-potential measurements during injection...  

Open Energy Info (EERE)

self-potential measurements during injection tests at Raft River, Idaho. Final report Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Report: Interpretation of...

106

Yet Another Fault Injection Technique : by Forward Body Biasing Injection  

E-Print Network (OSTI)

expensive fault injection tech- niques, like clock or voltage glitches, are well taken into accountYet Another Fault Injection Technique : by Forward Body Biasing Injection K. TOBICH1,2, P. MAURINE1 Injection, Electromag- netic Attacks, RSA, Chinese Remainder Theorem 1 Introduction Fault injection

107

Analysis of thermally induced permeability enhancement in geothermal injection wells  

DOE Green Energy (OSTI)

Reinjection of spent geothermal brine is a common means of disposing of geothermal effluents and maintaining reservoir pressures. Contrary to the predictions of two-fluid models (two-viscosity) of nonisothermal injection, an increase of injectivity, with continued injection, is often observed. Injectivity enhancement and thermally-affected pressure transients are particularly apparent in short-term injection tests at the Los Azufres Geothermal Field, Mexico. During an injection test, it is not uncommon to observe that after an initial pressure increase, the pressure decreases with time. As this typically occurs far below the pressure at which hydraulic fracturing is expected, some other mechanism for increasing the near-bore permeability must explain the observed behavior. This paper focuses on calculating the magnitude of the nearbore permeability changes observed in several nonisothermal injection tests conducted at the Los Azufres Geothermal Field.

Benson, S.M.; Daggett, J.S.; Iglesias, E.; Arellano, V.; Ortiz-Ramirez, J.

1987-02-01T23:59:59.000Z

108

Smart Materials for Fuel Injection Actuation  

DOE Green Energy (OSTI)

The demands of stringent emissions and a robust engine dynamic torque response characteristic require innovative, accurate and repeatable control of the fuel injection event. Recent advances in piezo-material actuators have warranted the pursuit of its application to advanced heavy-duty truck fuel injection systems. This presentation will report on design and testing of an advanced electronic unit injector for the Detroit Diesel Series 60 truck engine.

Hakim, Nabil

2000-08-20T23:59:59.000Z

109

Supported-sorbent injection. Final report  

Science Conference Proceedings (OSTI)

A new retrofitable, wastefree acid-rain control concept was pilot-tested at Ohio Edison`s high-sulfur coal-fired R.E. Burger generating station at the 2-MWe level. During the project, moistened {open_quotes}supported{close_quotes} sorbents, made from a combination of lime and vermiculite or perlite, were injected into a humidified 6,500-acfm flue-gas slipstream. After the sorbents reacted with the sulfur dioxide in the flue gas, they were removed from ductwork with a cyclone and baghouse. The $1.0 million project was co-funded by Sorbent Technologies Corporation, the Ohio Edison Company, and the Ohio Coal Development Office. The project included a preliminary bench-scale testing phase, construction of the pilot plant, parametric studies, numerous series of recycle tests, and a long-term run. The project proceeded as anticipated and achieved its expected results. This duct injection technology successfully demonstrated SO{sub 2}-removal rates of 80 to 90% using reasonable stoichiometric injection ratios (2:1 Ca:S) and approach temperatures (20-25F). Under similar conditions, dry injection of hydrated lime alone typically only achieves 40 to 50% SO{sub 2} removal. During the testing, no difficulties were encountered with deposits in the ductwork or with particulate control, which have been problems in tests of other duct-injection schemes.

Nelson, S. Jr.

1997-07-01T23:59:59.000Z

110

An Evaluation of the Carbon Sequestration Potential of the Cambro-Ordovician Strata of the Illinois and Michigan Basins: Part 1: Evaluation of Phase 2 CO{sub 2} Injection Testing in the Deep Saline Gunter Sandstone Reservoir (Cambro-Ordovician Knox Group), Marvin Blan No. 1 Hancock County, Kentucky Part 2: Time-lapse Three-Dimensional Vertical Seismic Profile (3D-VSP) of Sequestration Target Interval with Injected Fluids  

SciTech Connect

Part 1 of this report focuses on results of the western Kentucky carbon storage test, and provides a basis for evaluating injection and storage of supercritical CO{sub 2} in Cambro-Ordovician carbonate reservoirs throughout the U.S. Midcontinent. This test demonstrated that the Cambro- Ordovician Knox Group, including the Beekmantown Dolomite, Gunter Sandstone, and Copper Ridge Dolomite in stratigraphic succession from shallowest to deepest, had reservoir properties suitable for supercritical CO{sub 2} storage in a deep saline reservoir hosted in carbonate rocks, and that strata with properties sufficient for long-term confinement of supercritical CO{sub 2} were present in the deep subsurface. Injection testing with brine and CO{sub 2} was completed in two phases. The first phase, a joint project by the Kentucky Geological Survey and the Western Kentucky Carbon Storage Foundation, drilled the Marvin Blan No. 1 carbon storage research well and tested the entire Knox Group section in the open borehole â?? including the Beekmantown Dolomite, Gunter Sandstone, and Copper Ridge Dolomite â?? at 1152â??2255 m, below casing cemented at 1116 m. During Phase 1 injection testing, most of the 297 tonnes of supercritical CO{sub 2} was displaced into porous and permeable sections of the lowermost Beekmantown below 1463 m and Gunter. The wellbore was then temporarily abandoned with a retrievable bridge plug in casing at 1105 m and two downhole pressure-temperature monitoring gauges below the bridge plug pending subsequent testing. Pressure and temperature data were recorded every minute for slightly more than a year, providing a unique record of subsurface reservoir conditions in the Knox. In contrast, Phase 2 testing, this study, tested a mechanically-isolated dolomitic-sandstone interval in the Gunter. Operations in the Phase 2 testing program commenced with retrieval of the bridge plug and long-term pressure gauges, followed by mechanical isolation of the Gunter by plugging the wellbore with cement below the injection zone at 1605.7 m, then cementing a section of a 14-cm casing at 1470.4â??1535.6. The resultant 70.1-m test interval at 1535.6â??1605.7 m included nearly all of the Gunter sandstone facies. During the Phase 2 injection, 333 tonnes of CO{sub 2} were injected into the thick, lower sand section in the sandy member of the Gunter. Following the completion of testing, the injection zone below casing at 1116 m in the Marvin Blan No. 1 well, and wellbore below 305 m was permanently abandoned with cement plugs and the wellsite reclaimed. The range of most-likely storage capacities found in the Knox in the Marvin Blan No. 1 is 1000 tonnes per surface hectare in the Phase 2 Gunter interval to 8685 tonnes per surface hectare if the entire Knox section were available including the fractured interval near the base of the Copper Ridge. By itself the Gunter lacks sufficient reservoir volume to be considered for CO{sub 2} storage, although it may provide up to 18% of the reservoir volume available in the Knox. Regional extrapolation of CO{sub 2} storage potential based on the results of a single well test can be problematic, although indirect evidence of porosity and permeability can be demonstrated in the form of active saltwater-disposal wells injecting into the Knox. The western Kentucky region suitable for CO{sub 2} storage in the Knox is limited updip, to the east and south, by the depth at which the base of the Maquoketa shale lies above the depth required to ensure storage of CO{sub 2} in its supercritical state and the deepest a commercial well might be drilled for CO{sub 2} storage. The resulting prospective region has an area of approximately 15,600 km{sup 2}, beyond which it is unlikely that suitable Knox reservoirs may be developed. Faults in the subsurface, which serve as conduits for CO{sub 2} migration and compromise sealing strata, may mitigate the area with Knox reservoirs suitable for CO{sub 2} storage. The results of the injection tes

Richard Bowersox; John Hickman; Hannes Leetaru

2012-12-01T23:59:59.000Z

111

A study of steam injection in fractured media  

SciTech Connect

Steam injection is the most widely used thermal recovery technique for unfractured reservoirs containing heavy oil. There have been numerous studies on theoretical and experimental aspects of steam injection for such systems. Fractured reservoirs contain a large fraction of the world supply of oil, and field tests indicate that steam injection is feasible for such reservoirs. Unfortunately there has been little laboratory work done on steam injection in such systems. The experimental system in this work was designed to understand the mechanisms involved in the transfer of fluids and heat between matrix rocks and fractures under steam injection.

Dindoruk, M.D.S.; Aziz, K.; Brigham, W.; Castanier, L.

1996-02-01T23:59:59.000Z

112

Examinatal Study on Common Rail Diesel Engine for Multi-injection Strategies  

Science Conference Proceedings (OSTI)

Based on diesel engine equipped with common rail, the multi-injection strategies common rail diesel engine test bed is established with NI test system. In this test bed, the influences of optimized multi-injection strategies to diesel engine performances ... Keywords: common rail, diesel engine, multi-injection, emission

An Shijie; Chang Hanbao; Xu Hongjun

2010-05-01T23:59:59.000Z

113

Optimization of Injection Scheduling in  

E-Print Network (OSTI)

- of wells,and (2) allocating a total speci6cd injection rate among chosen injectors. The alloca- tion is defined as the fieldwide break- through lindex, B. Injection is optimized by choosing injection wells questions: (1) Which wells should be made injectors? (2) How should the total nquired injection rate

Stanford University

114

Integration of InSAR and GIS in the Study of Surface Faults Caused by Subsidence-Creep-Fault Processes in Celaya, Guanajuato, Mexico  

Science Conference Proceedings (OSTI)

In Celaya city, Subsidence-Creep-Fault Processes (SCFP) began to become visible at the beginning of the 1980s with the sprouting of the crackings that gave rise to the surface faults 'Oriente' and 'Poniente'. At the present time, the city is being affected by five surface faults that display a preferential NNW-SSE direction, parallel to the regional faulting system 'Taxco-San Miguel de Allende'. In order to study the SCFP in the city, the first step was to obtain a map of surface faults, by integrating in a GIS field survey and an urban city plan. The following step was to create a map of the current phreatic level decline in city with the information of deep wells and using the 'kriging' method in order to obtain a continuous surface. Finally the interferograms maps resulted of an InSAR analysis of 9 SAR images covering the time interval between July 12 of 2003 and May 27 of 2006 were integrated to a GIS. All the maps generated, show how the surface faults divide the city from North to South, in two zones that behave in a different way. The difference of the phreatic level decline between these two zones is 60 m; and the InSAR study revealed that the Western zone practically remains stable, while sinkings between the surface faults 'Oriente' and 'Universidad Pedagogica' are present, as well as in portions NE and SE of the city, all of these sinkings between 7 and 10 cm/year.

Avila-Olivera, Jorge A. [Instituto de Geofisica, Universidad Nacional Autonoma de Mexico, C.U., 04510 Mexico D.F. (Mexico); Instituto de Investigaciones Metalurgicas, Universidad Michoacana de San Nicolas de Hidalgo, C.U., 58030 Morelia, Michoacan (Mexico); Farina, Paolo [Dipartimento di Scienze della Terra, Universita degli Studi di Firenze, Via G. La Pira 4, 50121 Firenze (Italy); Garduno-Monroy, Victor H. [Instituto de Investigaciones Metalurgicas, Universidad Michoacana de San Nicolas de Hidalgo, C.U., 58030 Morelia, Michoacan (Mexico)

2008-05-07T23:59:59.000Z

115

AUGUST 2008 VOLUME 46 NUMBER 8 IGRSD2 (ISSN 0196-2892) C-band Radarsat-1 InSAR image shows water-level changes over the swamp forest in southeastern Louisiana between May 22 and June 15, 2003.  

E-Print Network (OSTI)

-level changes of coastal wetlands over southeastern Louisiana. The InSAR image suggests that water-level changes, and other species combine to place the coastal wetlands of Louisiana among the nation's most productive-level changes over the swamp forest in southeastern Louisiana between May 22 and June 15, 2003. In

116

NETL: Mercury Emissions Control Technologies - Sorbent Injection for Small  

NLE Websites -- All DOE Office Websites (Extended Search)

Sorbent Injection for Small ESP Mercury Control in Low Sulfur Eastern Bituminous Coal Flue Gas Sorbent Injection for Small ESP Mercury Control in Low Sulfur Eastern Bituminous Coal Flue Gas URS Group and their test team will evaluate sorbent injection for mercury control on sites with low-SCA ESPs, burning low sulfur Eastern bituminous coals. Full-scale tests will be performed at Plant Yates Units 1 and 2 to evaluate sorbent injection performance across a cold-side ESP/wet FGD and a cold-side ESP with a dual NH3/SO3 flue gas conditioning system, respectively. Short-term parametric tests on Units 1 and 2 will provide data on the effect of sorbent injection rate on mercury removal and ash/FGD byproduct composition. Tests on Unit 2 will also evaluate the effect of dual-flue gas conditioning on sorbent injection performance. Results from a one-month injection test on Unit 1 will provide insight to the long-term performance and variability of this process as well as any effects on plant operations. The goals of the long-term testing are to obtain sufficient operational data on removal efficiency over time, effects on the ESP and balance of plant equipment, and on injection equipment operation to prove process viability.

117

Fluid-Bed Testing of Greatpoint Energy's Direct Oxygen Injection Catalytic Gasification Process for Synthetic Natural Gas and Hydrogen Coproduction Year 6 - Activity 1.14 - Development of a National Center for Hydrogen Technology  

SciTech Connect

The GreatPoint Energy (GPE) concept for producing synthetic natural gas and hydrogen from coal involves the catalytic gasification of coal and carbon. GPEs technology refines coal by employing a novel catalyst to crack the carbon bonds and transform the coal into cleanburning methane (natural gas) and hydrogen. The GPE mild catalytic gasifier design and operating conditions result in reactor components that are less expensive and produce pipeline-grade methane and relatively high purity hydrogen. The system operates extremely efficiently on very low cost carbon sources such as lignites, subbituminous coals, tar sands, petcoke, and petroleum residual oil. In addition, GPEs catalytic coal gasification process eliminates troublesome ash removal and slagging problems, reduces maintenance requirements, and increases thermal efficiency, significantly reducing the size of the air separation plant (a system that alone accounts for 20% of the capital cost of most gasification systems) in the catalytic gasification process. Energy & Environmental Research Center (EERC) pilot-scale gasification facilities were used to demonstrate how coal and catalyst are fed into a fluid-bed reactor with pressurized steam and a small amount of oxygen to fluidize the mixture and ensure constant contact between the catalyst and the carbon particles. In this environment, the catalyst facilitates multiple chemical reactions between the carbon and the steam on the surface of the coal. These reactions generate a mixture of predominantly methane, hydrogen, and carbon dioxide. Product gases from the process are sent to a gas-cleaning system where CO{sub 2} and other contaminants are removed. In a full-scale system, catalyst would be recovered from the bottom of the gasifier and recycled back into the fluid-bed reactor. The by-products (such as sulfur, nitrogen, and CO{sub 2}) would be captured and could be sold to the chemicals and petroleum industries, resulting in near-zero hazardous air or water pollution. This technology would also be conducive to the efficient coproduction of methane and hydrogen while also generating a relatively pure CO{sub 2} stream suitable for enhanced oil recovery (EOR) or sequestration. Specific results of bench-scale testing in the 4- to 38-lb/hr range in the EERC pilot system demonstrated high methane yields approaching 15 mol%, with high hydrogen yields approaching 50%. This was compared to an existing catalytic gasification model developed by GPE for its process. Long-term operation was demonstrated on both Powder River Basin subbituminous coal and on petcoke feedstocks utilizing oxygen injection without creating significant bed agglomeration. Carbon conversion was greater than 80% while operating at temperatures less than 1400F, even with the shorter-than-desired reactor height. Initial designs for the GPE gasification concept called for a height that could not be accommodated by the EERC pilot facility. More gas-phase residence time should allow the syngas to be converted even more to methane. Another goal of producing significant quantities of highly concentrated catalyzed char for catalyst recovery and material handling studies was also successful. A PdCu membrane was also successfully tested and demonstrated to produce 2.54 lb/day of hydrogen permeate, exceeding the desired hydrogen permeate production rate of 2.0 lb/day while being tested on actual coal-derived syngas that had been cleaned with advanced warm-gas cleanup systems. The membranes did not appear to suffer any performance degradation after exposure to the cleaned, warm syngas over a nominal 100-hour test.

Swanson, Michael; Henderson, Ann

2012-04-01T23:59:59.000Z

118

Hydrothermal Injection Research Program. Annual progress report, FY 1983  

DOE Green Energy (OSTI)

The test program was initiated at the Raft River Geothermal Field in southern Idaho in September of 1982. A series of eight short-term injection and backflow tests followed by a long-term injection test were conducted on one well in the field. Tracers were added during injection and monitored during backflow of the well. The test program was successful, resulting in a unique data set which shows promise as a means to improve understanding of the reservoir characteristics. In December of 1982 an RFP was issued to obtain an industrial partner to obtain follow-on data on the injection/backflow technique in a second field and to study any alternate advanced concepts for injection testing which the industrial community might recommend. Republic Geothermal, Inc. and the East Mesa Geothermal Field were selected for the second test series. Two wells were utilized for testing, and a series of ten tests were conducted in July and August of 1983 aimed principally at further evaluation of the injection/backflow technique. This test program was also successfully completed. This report describes in detail the analysis conducted on the Raft River data, the supporting work at EG and G Idaho and at ESL/UURI, and gives an overview of the objectives and test program at East Mesa.

Blackett, R.E.; Kolesar, P.T.; Capuano, R.G.; Sill, W.R.; Allman, D.W.; Hull, L.C.; Large, R.M.; Miller, J.D.; Skiba, P.A.; Downs, W.F.; Koslow, K.N.; McAtee, R.E.; Russell, B.F.

1983-11-01T23:59:59.000Z

119

Injection in basin and range-type reservoirs: the Raft River experience  

DOE Green Energy (OSTI)

Injection testing at the Raft River KGRA has yielded some interesting results which can be useful in planning injection systems in Basin and Range type reservoirs. Because of inhomogeneities and possible fracturing in basin fill sediment, rapid pressure response to injection has been observed in one shallow monitor well, but not others. In some monitor wells in the injection field, pressure drops are observed during injection suggesting plastic deformation of the sediments. Seismicity, however, has not accompanied these observed water level changes.

Petty, S.; Spencer, S.

1981-01-01T23:59:59.000Z

120

Alkaline injection for enhanced oil recovery: a status report  

SciTech Connect

In the past several years, there has been renewed interest in enhanced oil recovery (EOR) by alkaline injection. Alkaline solutions also are being used as preflushes in micellar/polymer projects. Several major field tests of alkaline flooding are planned, are in progress, or recently have been completed. Considerable basic research on alkaline injection has been published recently, and more is in progress. This paper summarizes known field tests and, where available, the amount of alkali injected and the performance results. Recent laboratory work, much sponsored by the U.S. DOE, and the findings are described. Alkaline flood field test plans for new projects are summarized.

Mayer, E.H.; Berg, R.L.; Carmichael, J.D.; Weinbrandt, R.M.

1983-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "insar injectivity test" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Gaseous Fuel Injection Modeling using a Gaseous Sphere Injection Methodology  

DOE Green Energy (OSTI)

The growing interest in gaseous fuels (hydrogen and natural gas) for internal combustion engines calls for the development of computer models for simulation of gaseous fuel injection, air entrainment and the ensuing combustion. This paper introduces a new method for modeling the injection and air entrainment processes for gaseous fuels. The model uses a gaseous sphere injection methodology, similar to liquid droplet in injection techniques used for liquid fuel injection. In this paper, the model concept is introduced and model results are compared with correctly- and under-expanded experimental data.

Hessel, R P; Aceves, S M; Flowers, D L

2006-03-06T23:59:59.000Z

122

-Injection Technology -Geothermal Reservoir Engineering  

E-Print Network (OSTI)

the injection well to^ production wells along high conductivity fractures. A powerful method for investigat- ing fields typically choose a configuration for injection wells after a number of development wells have of cooler injected fluids at producing wells. The goal of the current #12;- 10 - work is to provide

Stanford University

123

Deformation Trend Extraction Based on Multi-Temporal InSAR in Shanghai  

E-Print Network (OSTI)

Abstract: Shanghai is a modern metropolis characterized by high urban density and anthropogenic ground motions. Although traditional deformation monitoring methods, such as GPS and spirit leveling, are reliable to millimeter accuracy, the sparse point subsidence information makes understanding large areas difficult. Multiple temporal space-borne synthetic aperture radar interferometry is a powerful high-accuracy (sub-millimeter) remote sensing tool for monitoring slow ground deformation for a large area with a high point density. In this paper, the Interferometric Point Target Time Series Analysis method is used to extract ground subsidence rates in Shanghai based on 31 C-Band and 35 X-Band synthetic aperture radar (SAR) images obtained by Envisat and COSMO SkyMed (CSK) satellites from 2007 to 2010. A significant subsidence funnel that was detected is located in the junction place between the Yangpu and the Hongkou Districts. A t-test is formulated to judge the agreements between the subsidence results obtained by SAR and by spirit leveling. In addition, four profile lines crossing the subsidence funnel area are chosen for a comparison of ground subsidence rates, which were obtained by the two different band

Jie Chen; Jicang Wu; Lina Zhang; Junping Zou; Guoxiang Liu; Rui Zhang; Bing Yu

2013-01-01T23:59:59.000Z

124

Improved screen-bowl centrifuge recovery using polymer injection technology  

Science Conference Proceedings (OSTI)

The paper reports the improved screen-bowl centrifuge recovery process using polymer injection technology. Field test and economic analysis are also included in the paper. 3 refs., 3 figs., 1 tab.

Burchett, R.T.; McGough, K.M.; Luttrell, G.H.

2006-08-15T23:59:59.000Z

125

Particle beam injection system  

SciTech Connect

This invention provides a poloidal divertor for stacking counterstreaming ion beams to provide high intensity colliding beams. To this end, method and apparatus are provided that inject high energy, high velocity, ordered, atomic deuterium and tritium beams into a lower energy, toroidal, thermal equilibrium, neutral, target plasma column that is magnetically confined along an endless magnetic axis in a strong restoring force magnetic field having helical field lines to produce counterstreaming deuteron and triton beams that are received bent, stacked and transported along the endless axis, while a poloidal divertor removes thermal ions and electrons all along the axis to increase the density of the counterstreaming ion beams and the reaction products resulting therefrom. By balancing the stacking and removal, colliding, strong focused particle beams, reaction products and reactions are produced that convert one form of energy into another form of energy.

Jassby, Daniel L. (Princeton, NJ); Kulsrud, Russell M. (Princeton, NJ)

1977-01-01T23:59:59.000Z

126

Stanford Geothermal Program, reservoir and injection technology  

DOE Green Energy (OSTI)

This annual report of the Stanford Geothermal Program presents major projects in reservoir and injection technology. The four include: (1) an application of the boundary element method to front tracking and pressure transient testing; (2) determination of fracture aperture, a multi-tracer approach; (3) an analysis of tracer and thermal transients during reinjection; and, (4) pressure transient modeling of a non-uniformly fractured reservoir. (BN)

Horne, R.; Ramey, H.J. Jr.; Miller, F.G.; Brigham, W.E.; Kruger, P.

1988-12-01T23:59:59.000Z

127

Processing of high salinity brines for subsurface injection  

DOE Green Energy (OSTI)

Different chemical pretreatments and filtration methods were evaluated as a possible means of clarifying and improving the injectivity of hypersaline brines. Six different downflow media combinations were evaluated over three geopressurized sites, using test data from 4 inch diameter filters. Also, tests were conducted with one hollow fiber ultrafilter unit and two types of disposable cartridge filters. The test procedures are mentioned briefly. (MHR)

Thompson, R.E.; Raber, E.

1979-08-06T23:59:59.000Z

128

Underground Injection Control Regulations (Kansas)  

Energy.gov (U.S. Department of Energy (DOE))

This article prohibits injection of hazardous or radioactive wastes into or above an underground source of drinking water, establishes permit conditions and states regulations for design,...

129

Underground Injection Control Rule (Vermont)  

Energy.gov (U.S. Department of Energy (DOE))

This rule regulates injection wells, including wells used by generators of hazardous or radioactive wastes, disposal wells within an underground source of drinking water, recovery of geothermal...

130

European Lean Gasoline Direct Injection Vehicle Benchmark  

DOE Green Energy (OSTI)

Lean Gasoline Direct Injection (LGDI) combustion is a promising technical path for achieving significant improvements in fuel efficiency while meeting future emissions requirements. Though Stoichiometric Gasoline Direct Injection (SGDI) technology is commercially available in a few vehicles on the American market, LGDI vehicles are not, but can be found in Europe. Oak Ridge National Laboratory (ORNL) obtained a European BMW 1-series fitted with a 2.0l LGDI engine. The vehicle was instrumented and commissioned on a chassis dynamometer. The engine and after-treatment performance and emissions were characterized over US drive cycles (Federal Test Procedure (FTP), the Highway Fuel Economy Test (HFET), and US06 Supplemental Federal Test Procedure (US06)) and steady state mappings. The vehicle micro hybrid features (engine stop-start and intelligent alternator) were benchmarked as well during the course of that study. The data was analyzed to quantify the benefits and drawbacks of the lean gasoline direct injection and micro hybrid technologies from a fuel economy and emissions perspectives with respect to the US market. Additionally that data will be formatted to develop, substantiate, and exercise vehicle simulations with conventional and advanced powertrains.

Chambon, Paul H [ORNL; Huff, Shean P [ORNL; Edwards, Kevin Dean [ORNL; Norman, Kevin M [ORNL; Prikhodko, Vitaly Y [ORNL; Thomas, John F [ORNL

2011-01-01T23:59:59.000Z

131

Optimization of injection scheduling in geothermal fields  

DOE Green Energy (OSTI)

This study discusses the application of algorithms developed in Operations Research to the optimization of brine reinjection in geothermal fields. The injection optimization problem is broken into two sub-problems: (1) choosing a configuration of injectors from an existing set of wells, and (2) allocating a total specified injection rate among chosen injectors. The allocation problem is solved first. The reservoir is idealized as a network of channels or arcs directly connecting each pair of wells in the field. Each arc in the network is considered to have some potential for thermal breakthrough. This potential is quantified by an arc-specific break-through index, b/sub ij/, based on user-specified parameters from tracer tests, field geometry, and operating considerations. The sum of b/sub ij/-values for all arcs is defined as the fieldwide breakthrough index, B. Injection is optimized by choosing injection wells and rates so as to minimize B subject to constraints on the number of injectors and the total amount of fluid to be produced and reinjected. The study presents four computer programs which employ linear or quadratic programming to solve the allocation problem. In addition, a program is presented which solves the injector configuration problem by a combination of enumeration and quadratic programming. The use of the various programs is demonstrated with reference both to hypothetical data and an actual data set from the Wairakei Geothermal Field in New Zealand.

Lovekin, J.

1987-05-01T23:59:59.000Z

132

Optimization of Injection Scheduling in Geothermal Fields  

DOE Green Energy (OSTI)

This study discusses the application of algorithms developed in Operations Research to the optimization of brine reinjection in geothermal fields. The injection optimization problem is broken into two sub-problems: (1) choosing a configuration of injectors from an existing set of wells, and (2) allocating a total specified injection rate among chosen injectors. The allocation problem is solved first. The reservoir is idealized as a network of channels or arcs directly connecting each pair of wells in the field. Each arc in the network is considered to have some potential for thermal breakthrough. This potential is quantified by an arc-specific breakthrough index, b{sub ij}, based on user-specified parameters from tracer tests, field geometry, and operating considerations. The sum of b{sub ij}-values for all arcs is defined as the fieldwide breakthrough index, B. Injection is optimized by choosing injection wells and rates so as to minimize B subject to constraints on the number of injectors and the total amount of fluid to be produced and reinjected. The use of the various methods is demonstrated with reference both to hypothetical data and an actual data set from the Wairakei Geothermal Field in New Zealand.

Lovekin, James; Horne, Roland N.

1989-03-21T23:59:59.000Z

133

Common Rail Injection System Development  

DOE Green Energy (OSTI)

The collaborative research program between the Department of energy and Electro-Motive Diesels, Inc. on the development of common rail fuel injection system for locomotive diesel engines that can meet US EPA Tier 2 exhaust emissions has been completed. This final report summarizes the objectives of the program, work scope, key accomplishments and research findings. The major objectives of this project encompassed identification of appropriate injection strategies by using advanced analytical tools, development of required prototype hardware/controls, investigations of fuel spray characteristics including cavitation phenomena, and validation of hareware using a single-cylinder research locomotive diesel engine. Major milestones included: (1) a detailed modeling study using advanced mathematical models - several various injection profiles that show simultaneous reduction of NOx and particulates on a four stroke-cycle locomotive diesel engine were identified; (2) development of new common rail fuel injection hardware capable of providing these injection profiles while meeting EMD engine and injection performance specifications. This hardware was developed together with EMD's current fuel injection component supplier. (3) Analysis of fuel spray characteristics. Fuel spray numerical studies and high speed photographic imaging analyses were performed. (4) Validation of new hardware and fuel injection profiles. EMD's single-cylinder research diesel engine located at Argonne National Laboratory was used to confirm emissions and performacne predictions. These analytical ane experimental investigations resulted in optimized fuel injection profiles and engine operating conditions that yield reductions in NOx emissions from 7.8 g/bhp-hr to 5.0 g/bhp-hr at full (rated) load. Additionally, hydrocarbon and particulate emissions were reduced considerably when compared to baseline Tier I levels. The most significant finding from the injection optimization process was a 2% to 3% improvement in fuel economy over EMD's traditional Tier I engine hardware configuration. the common rail fuel injection system enabled this added benefit by virtue of an inherent capability to provide multiple injections per power stroke at high fuel rail pressures. On the basis of the findings in this study, EMD concludes that the new electronically-controlled high-pressure common rail injection system has the potential to meet locomotive Tier 2 NOx and particulates emission standards without sacrificing the fuel economy. A number of areas to further improve the injection hardware and engine operating characteristics to further exploit the benefits of common rail injection system have also been identified.

Electro-Motive,

2005-12-30T23:59:59.000Z

134

Energy recovery by water injection  

DOE Green Energy (OSTI)

Several analytical and numerical studies that address injection and thermal breakthrough in fractured geothermal reservoirs are described. The results show that excellent thermal sweeps can be achieved in fractured reservoirs, and that premature cold water breakthrough can be avoided if the injection wells are appropriately located.

Witherspoon, P.A.; Bodvarsson, G.S.; Pruess, K.; Tsang, C.F.

1982-07-01T23:59:59.000Z

135

A Case History of Injection Through 1991 at Dixie Valley, Nevada | Open  

Open Energy Info (EERE)

Case History of Injection Through 1991 at Dixie Valley, Nevada Case History of Injection Through 1991 at Dixie Valley, Nevada Jump to: navigation, search OpenEI Reference LibraryAdd to library Journal Article: A Case History of Injection Through 1991 at Dixie Valley, Nevada Abstract The Dixie Valley injection system has been operational for 3 1/4 years and disperses injectate into the reservoir through three distinct geological environments. Short term step-rate injection tests underestimated the long term injectivity of some of the injectors requiring additional injectors to be drilled. Liberal use of surface discharge over three years allowed orderly development of an eight-well injection system that provides pressure support for nine production wells but has not yet resulted in any cooling problems. Tracer testing identified a single flow path while long

136

Improved Water Flooding through Injection Brine Modification  

Science Conference Proceedings (OSTI)

Crude oil/brine/rock interactions can lead to large variations in the displacement efficiency of waterflooding, by far the most widely applied method of improved oil recovery. Laboratory waterflood tests show that injection of dilute brine can increase oil recovery. Numerous fields in the Powder River basin have been waterflooded using low salinity brine (about 500 ppm) from the Madison limestone or Fox Hills sandstone. Although many uncertainties arise in the interpretation and comparison of field production data, injection of low salinity brine appears to give higher recovery compared to brine of moderate salinity (about 7,000 ppm). Laboratory studies of the effect of brine composition on oil recovery cover a wide range of rock types and crude oils. Oil recovery increases using low salinity brine as the injection water ranged from a low of no notable increase to as much as 37.0% depending on the system being studied. Recovery increases using low salinity brine after establishing residual oil saturation (tertiary mode) ranged from no significant increase to 6.0%. Tests with two sets of reservoir cores and crude oil indicated slight improvement in recovery for low salinity brine. Crude oil type and rock type (particularly the presence and distribution of kaolinite) both play a dominant role in the effect that brine composition has on waterflood oil recovery.

Robertson, Eric Partridge; Thomas, Charles Phillip; Morrow, Norman; (U of Wyoming)

2003-01-01T23:59:59.000Z

137

Injection, injectivity and injectability in geothermal operations: problems and possible solutions. Phase I. Definition of the problems  

DOE Green Energy (OSTI)

The following topics are covered: thermodynamic instability of brine, injectivity loss during regular production and injection operations, injectivity loss caused by measures other than regular operations, heat mining and associated reservoir problems in reinjection, pressure maintenance through imported make-up water, suggested solutions to injection problems, and suggested solutions to injection problems: remedial and stimulation measures. (MHR)

Vetter, O.J.; Crichlow, H.B.

1979-02-14T23:59:59.000Z

138

Combustion oscillation control by cyclic fuel injection  

SciTech Connect

A number of recent articles have demonstrated the use of active control to mitigate the effects of combustion instability in afterburner and dump combustor applications. In these applications, cyclic injection of small quantities of control fuel has been proposed to counteract the periodic heat release that contributes to undesired pressure oscillations. This same technique may also be useful to mitigate oscillations in gas turbine combustors, especially in test rig combustors characterized by acoustic modes that do not exist in the final engine configuration. To address this issue, the present paper reports on active control of a subscale, atmospheric pressure nozzle/combustor arrangement. The fuel is natural gas. Cyclic injection of 14% control fuel in a premix fuel nozzle is shown to reduce oscillating pressure amplitude by a factor of 0.30 (i.e., {approximately}10 dB) at 300 Hz. Measurement of the oscillating heat release is also reported.

Richards, G.A.; Yip, M.J. [USDOE Morgantown Energy Technology Center, WV (United States); Robey, E. [EG& G Technical Services of West Virginia, Morgantown Energy Technology Center, WV (United States); Cowell, L.; Rawlins, D. [Solar Turbines, Inc., San Diedgo, CA (United States)

1995-04-01T23:59:59.000Z

139

NEUTRAL-BEAM INJECTION  

SciTech Connect

The emphasis in the preceding chapters has been on magnetic confinement of high temperature plasmas. The question of production and heating of such plasmas has been dealt with relatively more briefly. It should not be inferred, however, that these matters must therefore be either trivial or unimportant. A review of the history reveals that in the early days all these aspects of the controlled fusion problem were considered to be on a par, and were tackled simultaneously and with equal vigor. Only the confinement problem turned out to be much more complex than initially anticipated, and richer in challenge to the plasma physicist than the questions of plasma production and heating. On the other hand, the properties of high-temperature plasmas and plasma confinement can only be studied experimentally after the problems of production and of heating to adequate temperatures are solved. It is the purpose of this and the next chapter to supplement the preceding discussions with more detail on two important subjects: neutral-beam injection and radio-frequency heating. These are the major contenders for heating in present and future tokamak and mirror fusion experiments, and even in several proposed reactors. For neutral beams we emphasize here the technology involved, which has undergone a rather remarkable development. The physics of particle and energy deposition in the plasma, and the discussion of the resulting effects on the confined plasma, have been included in previous chapters, and some experimental results are quoted there. Other heating processes of relevance to fusion are mentioned elsewhere in this book, in connection with the experiments where they are used: i.e. ohmic heating, adiabatic compression heating, and alpha-particle heating in Chapter 3 by H.P. Furth; more ohmic heating in Chapter 7, and shock-implosion heating, laser heating, and relativistic-electron beam heating in Chapter 8, both by W. E. Quinn. These methods are relatively straightforward in their physics and their technology, or in any case they are considered to be adequately covered by these other authors.

Kunkel, W.B.

1980-06-01T23:59:59.000Z

140

Injection nozzle for a turbomachine  

Science Conference Proceedings (OSTI)

A turbomachine includes a compressor, a combustor operatively connected to the compressor, an end cover mounted to the combustor, and an injection nozzle assembly operatively connected to the combustor. The injection nozzle assembly includes a first end portion that extends to a second end portion, and a plurality of tube elements provided at the second end portion. Each of the plurality of tube elements defining a fluid passage includes a body having a first end section that extends to a second end section. The second end section projects beyond the second end portion of the injection nozzle assembly.

Uhm, Jong Ho; Johnson, Thomas Edward; Kim, Kwanwoo

2012-09-11T23:59:59.000Z

Note: This page contains sample records for the topic "insar injectivity test" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

-OGP 04 (1) -Predicting Injectivity Decline  

E-Print Network (OSTI)

- OGP 04 (1) - Predicting Injectivity Decline in Water Injection Wells by Upscaling On-Site Core, resulting in injectivity decline of injection wells. Particles such as biomass, corrosion products, silt on permeability. These data were then processed, upscaled to model injection wells and, finally, history matched

Abu-Khamsin, Sidqi

142

PREFAIL: a programmable tool for multiple-failure injection  

Science Conference Proceedings (OSTI)

As hardware failures are no longer rare in the era of cloud computing, cloud software systems must "prevail" against multiple, diverse failures that are likely to occur. Testing software against multiple failures poses the problem of combinatorial explosion ... Keywords: distributed systems, fault injection, testing

Pallavi Joshi; Haryadi S. Gunawi; Koushik Sen

2011-10-01T23:59:59.000Z

143

Adaptive engine injection for emissions reduction  

DOE Patents (OSTI)

NOx and soot emissions from internal combustion engines, and in particular compression ignition (diesel) engines, are reduced by varying fuel injection timing, fuel injection pressure, and injected fuel volume between low and greater engine loads. At low loads, fuel is injected during one or more low-pressure injections occurring at low injection pressures between the start of the intake stroke and approximately 40 degrees before top dead center during the compression stroke. At higher loads, similar injections are used early in each combustion cycle, in addition to later injections which preferably occur between about 90 degrees before top dead center during the compression stroke, and about 90 degrees after top dead center during the expansion stroke (and which most preferably begin at or closely adjacent the end of the compression stroke). These later injections have higher injection pressure, and also lower injected fuel volume, than the earlier injections.

Reitz, Rolf D. (Madison, WI): Sun, Yong (Madison, WI)

2008-12-16T23:59:59.000Z

144

Massachusetts Natural Gas Underground Storage Injections All...  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Injections All Operators (Million Cubic Feet) Massachusetts Natural Gas Underground Storage Injections All Operators (Million Cubic Feet) Decade Year-0 Year-1...

145

Staged direct injection diesel engine  

DOE Patents (OSTI)

A diesel engine having staged injection for using lower cetane number fuels than No. 2 diesel fuel. The engine includes a main fuel injector and a pilot fuel injector. Pilot and main fuel may be the same fuel. The pilot injector injects from five to fifteen percent of the total fuel at timings from 20.degree. to 180.degree. BTDC depending upon the quantity of pilot fuel injected, the fuel cetane number and speed and load. The pilot fuel injector is directed toward the centerline of the diesel cylinder and at an angle toward the top of the piston, avoiding the walls of the cylinder. Stratification of the early injected pilot fuel is needed to reduce the fuel-air mixing rate, prevent loss of pilot fuel to quench zones, and keep the fuel-air mixture from becoming too fuel lean to become effective. In one embodiment, the pilot fuel injector includes a single hole for injection of the fuel and is directed at approximately 48.degree. below the head of the cylinder.

Baker, Quentin A. (San Antonio, TX)

1985-01-01T23:59:59.000Z

146

Development of an injection augmentation program at the Dixie Valley,  

Open Energy Info (EERE)

an injection augmentation program at the Dixie Valley, an injection augmentation program at the Dixie Valley, Nevada geothermal field Jump to: navigation, search OpenEI Reference LibraryAdd to library Conference Paper: Development of an injection augmentation program at the Dixie Valley, Nevada geothermal field Abstract Evaporative cooling at geothermal power plants generally reduces reservoir pressures even if all available geothermal liquids are reinjected. Controlled programs of injecting non geothermal waters directly into reservoirs have been tested or implemented at only four fields, three of them being vapor dominated. At the liquid-dominated Dixie Valley geothermal field an unsuccessful search for a large volume source of warm,chemically desirable fluid for augmentation was conducted.After determining water

147

Tracer Recovery and Mixing from Two Geothermal Injection-Backflow Studies |  

Open Energy Info (EERE)

Tracer Recovery and Mixing from Two Geothermal Injection-Backflow Studies Tracer Recovery and Mixing from Two Geothermal Injection-Backflow Studies Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Conference Proceedings: Tracer Recovery and Mixing from Two Geothermal Injection-Backflow Studies Details Activities (2) Areas (2) Regions (0) Abstract: Injection-backflow tracer testing on a single well is not a commonly used procedure for geothermal reservoir evaluation, and, consequently, there is little published information on the character or interpretation of tracer recovery curves. Two field experiments were conducted to develop chemical tracer procedures for use with injection-backflow testing, one on the fracture-permeability Raft River reservoir and the other on the matrix-permeability East Mesa reservoir. Results from tests conducted with incremental increases in the injection

148

Conditioning of geothermal brine effluents for injection: use of coagulants  

DOE Green Energy (OSTI)

The use of various chemical coagulants and flocculants with spent geothermal brine for enhancing the removal of colloidal solids prior to injection was studied. Brine at 80 to 85/sup 0/C was obtained from the injection line of the SDG and E/DOE Geothermal Loop Experimental Facility during a period of operation with Magmamax No. 1 Fluid. The solids consist primarily of an iron-rich amorphous silica and heavy metal sulfides, principally lead. Standard jar testing equipment was used to carry out the tests.

Quong, R.; Shoepflin, F.; Stout, N.D.

1978-02-01T23:59:59.000Z

149

Evaluation of Sorbent Injection for Mercury Control  

Science Conference Proceedings (OSTI)

The power industry in the U.S. is faced with meeting new regulations to reduce the emissions of mercury compounds from coal-fired plants. These regulations are directed at the existing fleet of nearly 1,100 boilers. These plants are relatively old with an average age of over 40 years. Although most of these units are capable of operating for many additional years, there is a desire to minimize large capital expenditures because of the reduced (and unknown) remaining life of the plant to amortize the project. Injecting a sorbent such as powdered activated carbon into the flue gas represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. The overall objective of the test program described in this quarterly report is to evaluate the capabilities of activated carbon injection at five plants with configurations that together represent 78% of the existing coal-fired generation plants. This technology was successfully evaluated in NETL's Phase I tests at scales up to 150 MW, on plants burning subbituminous and bituminous coals and with ESPs and fabric filters. The tests also identified issues that still need to be addressed, such as evaluating performance on other configurations, optimizing sorbent usage (costs), and gathering longer-term operating data to address concerns about the impact of activated carbon on plant equipment and operations. The four sites identified for testing are Sunflower Electric's Holcomb Station, AmerenUE's Meramec Station, AEP's Conesville Station, and Detroit Edison's Monroe Power Plant. In addition to tests identified for the four main sites, parametric testing at Missouri Basin Power Project's Laramie River Station Unit 3 has been scheduled and made possible through additional costshare participation targeted by team members specifically for tests at Holcomb or a similar plant. This is the fifth quarterly report for this project. Long-term testing was completed at Meramec during this reporting period. Preliminary results from parametric, baseline and long-term testing at Meramec are included in this report. Planning information for the other three sites is also included. In general, quarterly reports will be used to provide project overviews, project status, and technology transfer information. Topical reports will be prepared to present detailed technical information.

Sharon Sjostrom

2005-02-02T23:59:59.000Z

150

-Injection Technology -Geothermal Reservoir Engineering  

E-Print Network (OSTI)

.A. Hsieh 1e$ Pressure Buildup Monitoring of the Krafla Geothermal Field, . . . . . . . . 1'1 Xceland - 0 Initial Chemical and Reservoir Conditions at Lo6 Azufres Wellhead Power Plant Startup - P. Kruger, LSGP-TR-92 - Injection Technology - Geothermal Reservoir Engineering Research at Stanford Principal

Stanford University

151

CO2 Injection Begins in Illinois | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Begins in Illinois Begins in Illinois CO2 Injection Begins in Illinois November 17, 2011 - 12:00pm Addthis Washington, DC - The Midwest Geological Sequestration Consortium (MGSC), one of seven regional partnerships created by the U.S. Department of Energy (DOE) to advance carbon storage technologies nationwide, has begun injecting carbon dioxide (CO2) for their large-scale CO2 injection test in Decatur, Illinois. The test is part of the development phase of the Regional Carbon Sequestration Partnerships program, an Office of Fossil Energy initiative launched in 2003 to determine the best approaches for capturing and permanently storing gases that can contribute to global climate change. "Establishing long-term, environmentally safe and secure underground CO2 storage is a critical component in achieving successful commercial

152

Geothermal injection treatment: process chemistry, field experiences, and design options  

DOE Green Energy (OSTI)

The successful development of geothermal reservoirs to generate electric power will require the injection disposal of approximately 700,000 gal/h (2.6 x 10/sup 6/ 1/h) of heat-depleted brine for every 50,000 kW of generating capacity. To maintain injectability, the spent brine must be compatible with the receiving formation. The factors that influence this brine/formation compatibility and tests to quantify them are discussed in this report. Some form of treatment will be necessary prior to injection for most situations; the process chemistry involved to avoid and/or accelerate the formation of precipitate particles is also discussed. The treatment processes, either avoidance or controlled precipitation approaches, are described in terms of their principles and demonstrated applications in the geothermal field and, when such experience is limited, in other industrial use. Monitoring techniques for tracking particulate growth, the effect of process parameters on corrosion and well injectability are presented. Examples of brine injection, preinjection treatment, and recovery from injectivity loss are examined and related to the aspects listed above.

Kindle, C.H.; Mercer, B.W.; Elmore, R.P.; Blair, S.C.; Myers, D.A.

1984-09-01T23:59:59.000Z

153

Development of Improved Oil Field Waste Injection Disposal Techniques  

Science Conference Proceedings (OSTI)

The goals of this DOE sponsored project are to: (1) assemble and analyze a comprehensive database of past waste injection operations; (2) develop improved diagnostic techniques for monitoring fracture growth and formation changes; (3) develop operating guidelines to optimize daily operations and ultimate storage capacity of the target formation; and (4) to test these improved models and guidelines in the field.

Terralog Technologies USA Inc.

2001-12-17T23:59:59.000Z

154

carbon sequestration via direct injection  

NLE Websites -- All DOE Office Websites (Extended Search)

SEQUESTRATION VIA DIRECT INJECTION SEQUESTRATION VIA DIRECT INJECTION Howard J. Herzog, Ken Caldeira, and Eric Adams INTRODUCTION The build-up of carbon dioxide (CO 2 ) and other greenhouse gases in the Earth's atmosphere has caused concern about possible global climate change. As a result, international negotiations have produced the Framework Convention on Climate Change (FCCC), completed during the 1992 Earth Summit in Rio de Janeiro. The treaty, which the United States has ratified, calls for the "stabilization of greenhouse gas concentrations in the atmosphere at a level that would prevent dangerous anthropogenic interference with the climate system." The primary greenhouse gas is CO 2 , which is estimated to contribute to over two-thirds of any climate change. The primary source of CO

155

Miniaturized flow injection analysis system  

DOE Patents (OSTI)

A chemical analysis technique known as flow injection analysis, wherein small quantities of chemical reagents and sample are intermixed and reacted within a capillary flow system and the reaction products are detected optically, electrochemically, or by other means. A highly miniaturized version of a flow injection analysis system has been fabricated utilizing microfabrication techniques common to the microelectronics industry. The microflow system uses flow capillaries formed by etching microchannels in a silicon or glass wafer followed by bonding to another wafer, commercially available microvalves bonded directly to the microflow channels, and an optical absorption detector cell formed near the capillary outlet, with light being both delivered and collected with fiber optics. The microflow system is designed mainly for analysis of liquids and currently measures 38.times.25.times.3 mm, but can be designed for gas analysis and be substantially smaller in construction.

Folta, James A. (Livermore, CA)

1997-01-01T23:59:59.000Z

156

Miniaturized flow injection analysis system  

DOE Patents (OSTI)

A chemical analysis technique known as flow injection analysis is described, wherein small quantities of chemical reagents and sample are intermixed and reacted within a capillary flow system and the reaction products are detected optically, electrochemically, or by other means. A highly miniaturized version of a flow injection analysis system has been fabricated utilizing microfabrication techniques common to the microelectronics industry. The microflow system uses flow capillaries formed by etching microchannels in a silicon or glass wafer followed by bonding to another wafer, commercially available microvalves bonded directly to the microflow channels, and an optical absorption detector cell formed near the capillary outlet, with light being both delivered and collected with fiber optics. The microflow system is designed mainly for analysis of liquids and currently measures 38{times}25{times}3 mm, but can be designed for gas analysis and be substantially smaller in construction. 9 figs.

Folta, J.A.

1997-07-01T23:59:59.000Z

157

Radial lean direct injection burner  

Science Conference Proceedings (OSTI)

A burner for use in a gas turbine engine includes a burner tube having an inlet end and an outlet end; a plurality of air passages extending axially in the burner tube configured to convey air flows from the inlet end to the outlet end; a plurality of fuel passages extending axially along the burner tube and spaced around the plurality of air passage configured to convey fuel from the inlet end to the outlet end; and a radial air swirler provided at the outlet end configured to direct the air flows radially toward the outlet end and impart swirl to the air flows. The radial air swirler includes a plurality of vanes to direct and swirl the air flows and an end plate. The end plate includes a plurality of fuel injection holes to inject the fuel radially into the swirling air flows. A method of mixing air and fuel in a burner of a gas turbine is also provided. The burner includes a burner tube including an inlet end, an outlet end, a plurality of axial air passages, and a plurality of axial fuel passages. The method includes introducing an air flow into the air passages at the inlet end; introducing a fuel into fuel passages; swirling the air flow at the outlet end; and radially injecting the fuel into the swirling air flow.

Khan, Abdul Rafey; Kraemer, Gilbert Otto; Stevenson, Christian Xavier

2012-09-04T23:59:59.000Z

158

Dry Sorbent Injection Workshop Summary: Workshop Held November 11, 2011  

Science Conference Proceedings (OSTI)

A day-long dry sorbent injection (DSI) workshop was held in Charlotte, North Carolina, on November 20, 2011. The workshop was attended by representatives of over 20 electric power companies. Introductory remarks were made by Electric Power Research Institute (EPRI) staff, followed by presentations by 10 electric power companies describing their efforts and results from testing DSI technology for control of acid gases from flue gas. These testing efforts considered sulfur trioxide (SO3)/sulfuric acid, hyd...

2012-04-20T23:59:59.000Z

159

Geothermal Injection Technology Program: Annual progress report, Fiscal Year 1986  

DOE Green Energy (OSTI)

This report summarizes the Geothermal Injection Technology Program major activities in fiscal year 1986. The Idaho Engineering Laboratory (INEL) and the University of Utah Research Institute (UURI) have been conducting injection research and testing for this program, which was initiated in 1983. Activities at the INEL, representative element nodeling of fracture systems based on stochastic analysis, dual permeability modeling of flow in a fractured geothermal reservoir, and dual permeability model - laboratory and FRACSL-validation studies, are presented first, followed by the University of Utah Research Institute tracer development - experimental studies, which includes a brief description of activities planned for FY-1987.

Not Available

1987-07-01T23:59:59.000Z

160

An environmental analysis of injection molding  

E-Print Network (OSTI)

This thesis investigates injection molding from an environmental standpoint, yielding a system-level environmental analysis of the process. There are three main objectives: analyze the energy consumption trends in injection ...

Thiriez, Alexandre

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "insar injectivity test" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Experience with Zinc Injection in European PWRs  

Science Conference Proceedings (OSTI)

Zinc injection is an effective technique for lowering shutdown dose rates in pressurized water reactors (PWRs). This report compiles information about zinc injection experience at Siemens PWRs and compares the results with the use of zinc injection at U.S. PWRs. The plant data confirm that even low concentrations of zinc in the reactor water can indeed lower shutdown dose rates, but plants should make a concerted effort to inject zinc on a continuous basis to achieve the best results.

2002-11-01T23:59:59.000Z

162

Evaluation of Sorbent Injection for Mercury Control  

SciTech Connect

The power industry in the U.S. is faced with meeting new regulations to reduce the emissions of mercury compounds from coal-fired plants. These regulations are directed at the existing fleet of nearly 1,100 boilers. These plants are relatively old with an average age of over 40 years. Although most of these units are capable of operating for many additional years, there is a desire to minimize large capital expenditures because of the reduced (and unknown) remaining life of the plant to amortize the project. Injecting a sorbent such as powdered activated carbon into the flue gas represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. This is the final site report for tests conducted at DTE Energy's Monroe Power Plant, one of five sites evaluated in this DOE/NETL program. The overall objective of the test program was to evaluate the capabilities of activated carbon injection at five plants: Sunflower Electric's Holcomb Station Unit 1, AmerenUE's Meramec Station Unit 2, Missouri Basin Power Project's Laramie River Station Unit 3, Detroit Edison's Monroe Power Plant Unit 4, and AEP's Conesville Station Unit 6. These plants have configurations that together represent 78% of the existing coal-fired generation plants. The goals for the program established by DOE/NETL were to reduce the uncontrolled mercury emissions by 50 to 70% at a cost 25 to 50% lower than the target established by DOE of $60,000/lb mercury removed. The results from Monroe indicate that using DARCO{reg_sign} Hg would result in higher mercury removal (80%) at a sorbent cost of $18,000/lb mercury, or 70% lower than the benchmark. These results demonstrate that the goals established by DOE/NETL were exceeded during this test program. The increase in mercury removal over baseline conditions is defined for this program as a comparison in the outlet emissions measured using the Ontario Hydro method during the baseline and long-term test periods. The change in outlet emissions from baseline to long-term testing was 81%.

Sharon Sjostrom

2006-04-30T23:59:59.000Z

163

Evaluation of Sorbent Injection for Mercury Control  

Science Conference Proceedings (OSTI)

The power industry in the U.S. is faced with meeting new regulations to reduce the emissions of mercury compounds from coal-fired plants. These regulations are directed at the existing fleet of nearly 1,100 boilers. These plants are relatively old with an average age of over 40 years. Although most of these units are capable of operating for many additional years, there is a desire to minimize large capital expenditures because of the reduced (and unknown) remaining life of the plant to amortize the project. Injecting a sorbent such as powdered activated carbon into the flue gas represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. This is the final site report for tests conducted at Laramie River Station Unit 3, one of five sites evaluated in this DOE/NETL program. The overall objective of the test program is to evaluate the capabilities of activated carbon injection at five plants: Sunflower Electric's Holcomb Station Unit 1, AmerenUE's Meramec Station Unit 2, Missouri Basin Power Project's Laramie River Station Unit 3, Detroit Edison's Monroe Power Plant Unit 4, and AEP's Conesville Station Unit 6. These plants have configurations that together represent 78% of the existing coal-fired generation plants. The goals for the program established by DOE/NETL are to reduce the uncontrolled mercury emissions by 50 to 70% at a cost 25 to 50% lower than the benchmark established by DOE of $60,000/lb mercury removed. The goals of the program were exceeded at Laramie River Station by achieving over 90% mercury removal at a sorbent cost of $3,980/lb ($660/oz) mercury removed for a coal mercury content of 7.9 lb/TBtu.

Sharon Sjostrom

2005-12-30T23:59:59.000Z

164

Predicting the rate by which suspended solids plug geothermal injection wells  

DOE Green Energy (OSTI)

Standard membrane filtration tests were used to evaluate injection at the Salton Sea Geothermal Field, Southern California. Results indicate that direct injection into reservoir zones with primary porosity is not feasible unless 1 ..mu..m or larger particulates formed during or after the energy conversion process are removed. (JGB)

Owens, L.B.; Kasameyer, P.W.; Netherton, R.; Thorson, L.

1978-01-09T23:59:59.000Z

165

Manufacturing injection-moleded Fresnel lens parquets for point-focus concentrating photovoltaic systems  

DOE Green Energy (OSTI)

This project involved the manufacturing of curved-faceted, injection-molded, four-element Fresnel lens parquets for concentrating photovoltaic arrays. Previous efforts showed that high-efficiency (greater than 82%) Fresnel concentrators could be injection molded. This report encompasses the mold design, molding, and physical testing of a four-lens parquet for a solar photovoltaic concentrator system.

Peters, E.M.; Masso, J.D. [AOtec, Southbridge, MA (United States)

1995-10-01T23:59:59.000Z

166

Fuel injection device and method  

DOE Patents (OSTI)

A fuel injection system and method provide for shaping a combustion plume within a combustion chamber to effectively recirculate hot combustion gases for stable combustion conditions while providing symmetrical combustion conditions. Char and molten slag are passed to the outer boundary layer to complete combustion of char while permitting initial substoichiometric combustion in a reductive atmosphere for reducing discharge of nitrogen oxides. Shaping of the plume is accomplished by an axially adjustable pintle which permits apportionment of driving pressure between elements which contribute tangential and those which contribute radial directional components to oxidant flow entering the combustion chamber.

Carlson, Larry W. (Oswego, IL)

1986-01-01T23:59:59.000Z

167

Fuel injection device and method  

DOE Patents (OSTI)

A fuel injection system and method provide for shaping a combustion plume within a combustion chamber to effectively recirculate hot combustion gases for stable combustion conditions while providing symmetrical combustion conditions. Char and molten slag are passed to the outer boundary layer to complete combustion of char while permitting initial substoichiometric combustion in a reductive atmosphere for reducing discharge of nitrogen oxides. Shaping of the plume is accomplished by an axially adjustable pintle which permits apportionment of driving pressure between elements which contribute tangential and those which contribute radial directional components to oxidant flow entering the combustion chamber.

Carlson, L.W.

1983-12-21T23:59:59.000Z

168

INJECTIVE COGENERATORS AMONG OPERATOR BIMODULES  

E-Print Network (OSTI)

Abstract. Given C ?-algebras A and B acting cyclically on Hilbert spaces H and K, respectively, we characterize completely isometric A, B-bimodule maps from B(K, H) into operator A, B-bimodules. We determine cogenerators in some classes of operator bimodules. For an injective cogenerator X in a suitable category of operator A, B-bimodules we show: if A, regarded as a C ?-subalgebra of A?(X) (adjointable left multipliers on X), is equal to its relative double commutant in A?(X), then A must be a W ?-algebra. 1.

Bojan Magajna

2005-01-01T23:59:59.000Z

169

NETL: Mercury Emissions Control Technologies - Long-Term Carbon Injection  

NLE Websites -- All DOE Office Websites (Extended Search)

Long-Term Carbon Injection Field Test for > 90% Long-Term Carbon Injection Field Test for > 90% Mercury Removal for a PRB Unit with a Spray Drier and Fabric Filter The intent of DOE's Phase I and II field tests was to work with industry to evaluate the most promising mercury control technologies at full-scale in a variety of configurations. Although longer-term tests were conducted, the test period was not sufficient to answer many fundamental questions about long-term consistency of mercury removal and reliability of the system when integrated with plant processes. As the technologies move towards commercial implementation, it is critical to accurately define the mercury removal performance and costs so that power companies and policy makers can make informed decisions. Therefore, the overall objective of this Phase III project is to determine the mercury removal performance, long-term emissions variability, and associated O&M costs of activated carbon injection for >90% mercury control over a 10 to 12 month period on a unit that represents the combination of coal and emission control equipment that will be used for many new and existing power plants.

170

NETL: News Release - Alabama Injection Project Aimed at Enhanced Oil  

NLE Websites -- All DOE Office Websites (Extended Search)

March 1, 2010 March 1, 2010 Alabama Injection Project Aimed at Enhanced Oil Recovery, Testing Important Geologic CO2 Storage DOE-Sponsored Citronelle Project Appears Ideal Location for Concurrent CO2 Sequestration and EOR Operations Washington, D.C. - Carbon dioxide (CO2) injection - an important part of carbon capture and storage (CCS) technology - is underway as part of a pilot study of CO2 enhanced oil recovery (EOR) in the Citronelle Field of Mobile County, Alabama. A project team led by the University of Alabama at Birmingham is conducting the injection. Study results of the 7,500-ton CO2 injection will provide estimates of oil yields from EOR and CO2 storage capacity in depleted oil reservoirs. In the United States, CO2 injection has already helped recover nearly 1.5 billion barrels of oil from mature oil fields, yet the technology has not been deployed widely. It is estimated that nearly 400 billion barrels of oil still remain trapped in the ground. Funded through the Department of Energy's Office of Fossil Energy, the primary goal of the Citronelle Project is to demonstrate that remaining oil can be economically produced using CO2-EOR technology in untested areas of the United States, thereby reducing dependency on oil imports, providing domestic jobs, and preventing the release of CO2 into the atmosphere.

171

Sorbent Injection for Small ESP Mercury Control in Low Sulfur Eastern Bituminous Coal Flue Gas  

NLE Websites -- All DOE Office Websites (Extended Search)

Sorbent InjectIon for Small eSP Sorbent InjectIon for Small eSP mercury control In low Sulfur eaStern bItumInouS coal flue GaS Background Full-scale field testing has demonstrated the effectiveness of activated carbon injection (ACI) as a mercury-specific control technology for certain coal-fired power plants, depending on the plant's coal feedstock and existing air pollution control device configuration. In a typical configuration, powdered activated carbon (PAC) is injected downstream of the plant's air heater and upstream of the existing particulate control device - either an electrostatic precipitator (ESP) or a fabric filter (FF). The PAC adsorbs the mercury from the combustion flue gas and is subsequently captured along with the fly ash in the ESP or FF. ACI can have some negative side

172

Carbon Storage Partner Completes First Year of CO2 Injection Operations in  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Storage Partner Completes First Year of CO2 Injection Storage Partner Completes First Year of CO2 Injection Operations in Illinois Carbon Storage Partner Completes First Year of CO2 Injection Operations in Illinois November 19, 2012 - 12:00pm Addthis Washington, DC - A project important to demonstrating the commercial viability of carbon capture, utilization and storage (CCUS) technology has completed the first year of injecting carbon dioxide (CO2) from an industrial plant at a large-scale test site in Illinois. Led by the Illinois State Geological Survey, the Illinois Basin-Decatur Project is the first demonstration-scale project in the United States to use CO2 from an industrial source and inject it into a saline reservoir. The CO2 is being captured from an ethanol production facility operated by the Archer Daniels Midland Company in Decatur, Ill., and is being injected

173

Injection of Zero Valent Iron into an Unconfined Aquifer Using Shear-Thinning Fluids  

Science Conference Proceedings (OSTI)

Approximately 190 kg of two micron-diameter zero-valent iron (ZVI) particles were injected into a test zone in the top two meters of an unconfined aquifer within a trichloroethene (TCE) source area. A shear-thinning fluid was used to enhance ZVI delivery in the subsurface to a radial distance of up to four meters from a single injection well. The ZVI particles were mixed in-line with the injection water, shear-thinning fluid, and a low concentration of surfactant. ZVI was observed at each of the seven monitoring wells within the targeted radius of influence during injection. Additionally, all wells within the targeted zone showed low TCE concentrations and primarily dechlorination products present 44 days after injection. These results suggest that ZVI can be directly injected into an aquifer with shear-thinning fluids and extends the applicability of ZVI to situations where other emplacement methods may not be viable.

Truex, Michael J.; Vermeul, Vincent R.; Mendoza, Donaldo P.; Fritz, Brad G.; Mackley, Rob D.; Oostrom, Martinus; Wietsma, Thomas W.; Macbeth, Tamzen

2011-02-18T23:59:59.000Z

174

Allergy Injection Policy | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Allergy Injection Policy Allergy Injection Policy Allergy Injection Policy Millions of Americans suffer from perennial and seasonal allergic rhinitis. Allergy immunotherapy is an effective way to reduce or eliminate the symptoms of allergic rhinitis by desensitizing the patient to the allergen(s) by giving escalating doses of an extract via regular injections. Receiving weekly injections at a private physician's office is time consuming, reduces productivity, and can quickly deplete an employee's earned leave. FOH offers the convenience of receiving allergy injections at the OHC as a physician-prescribed service, reducing time away from work for many federal employees. Allergy Injection Policy.pdf More Documents & Publications Physician Treatment Order Handicapped Parking Guidance

175

Carbon Sequestration Partner Initiates Drilling of CO2 Injection Well in  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Sequestration Partner Initiates Drilling of CO2 Injection Sequestration Partner Initiates Drilling of CO2 Injection Well in Illinois Basin Carbon Sequestration Partner Initiates Drilling of CO2 Injection Well in Illinois Basin February 17, 2009 - 12:00pm Addthis Washington, D.C. -- The Midwest Geological Sequestration Consortium (MGSC), one of seven regional partnerships created by the U.S. Department of Energy (DOE) to advance carbon sequestration technologies nationwide, has begun drilling the injection well for their large-scale carbon dioxide (CO2) injection test in Decatur, Illinois. The test is part of the development phase of the Regional Carbon Sequestration Partnerships program, an Office of Fossil Energy initiative launched in 2003 to determine the best approaches for capturing and permanently storing gases that can contribute

176

Test Automation Test Automation  

E-Print Network (OSTI)

Test Automation Test Automation Mohammad Mousavi Eindhoven University of Technology, The Netherlands Software Testing 2013 Mousavi: Test Automation #12;Test Automation Outline Test Automation Mousavi: Test Automation #12;Test Automation Why? Challenges of Manual Testing Test-case design: Choosing inputs

Mousavi, Mohammad

177

Evaluation of Sorbent Injection for Mercury Control  

Science Conference Proceedings (OSTI)

ADA-ES, Inc., with support from DOE/NETL, EPRI, and industry partners, studied mercury control options at six coal-fired power plants. The overall objective of the this test program was to evaluate the capabilities of activated carbon injection at six plants: Sunflower Electric's Holcomb Station Unit 1, AmerenUE's Meramec Station Unit 2, Missouri Basin Power Project's Laramie River Station Unit 3, Detroit Edison's Monroe Power Plant Unit 4, American Electric Power's Conesville Station Unit 6, and Labadie Power Plant Unit 2. These plants have configurations that together represent 78% of the existing coal-fired generation plants. The financial goals for the program established by DOE/NETL were to reduce the uncontrolled mercury emissions by 50 to 70% at a cost 25 to 50% lower than the target established by DOE of $60,000 per pound of mercury removed. Results from testing at Holcomb, Laramie, Meramec, Labadie, and Monroe indicate the DOE goal was successfully achieved. However, further improvements for plants with conditions similar to Conesville are recommended that would improve both mercury removal performance and economics.

Sharon Sjostrom

2008-06-30T23:59:59.000Z

178

Experiences from First Top-Off Injection at the Stanford Synchrotron Radiation Lightsource  

Science Conference Proceedings (OSTI)

As the Stanford Synchrotron Radiation Lightsource (SSRL) of the SLAC National Accelerator Laboratory (SLAC) is moving toward Top-Off injection mode, SLAC's Radiation Protection Department is working with SSRL on minimizing the radiological hazards of this mode. One such hazard is radiation that is created inside the accelerator concrete enclosure by injected beam. Since during Top-Off injection the stoppers that would otherwise isolate the storage ring from the experimental area stay open, the stoppers no longer prevent such radiation from reaching the experimental area. The level of this stray radiation was measured in April 2008 during the first Top-Off injection tests. They revealed radiation dose rates of up to 18 microSv/h (1.8 millirem/h) outside the experimental hutches, significantly higher than our goal of 1 microSv/h (0.1 millirem/h). Non-optimal injection increased the measured dose rates by a factor two. Further tests in 2008 indicated that subsequent improvements by SSRL to the injection system have reduced the dose rates to acceptable levels. This presentation describes the studies performed before the Top-Off tests, the tests themselves and their major results (both under initial conditions and after improvements were implemented), and presents the controls being implemented for full and routine Top-Off injection.

Bauer, J.M.; Liu, J.C.; Prinz, A.; Rokni, S.H.; /SLAC

2009-12-11T23:59:59.000Z

179

Stanford Geothermal Program, reservoir and injection technology. Fourth annual report  

DOE Green Energy (OSTI)

This annual report of the Stanford Geothermal Program presents major projects in reservoir and injection technology. The four include: (1) an application of the boundary element method to front tracking and pressure transient testing; (2) determination of fracture aperture, a multi-tracer approach; (3) an analysis of tracer and thermal transients during reinjection; and, (4) pressure transient modeling of a non-uniformly fractured reservoir. (BN)

Horne, R.; Ramey, H.J. Jr.; Miller, F.G.; Brigham, W.E.; Kruger, P.

1988-12-01T23:59:59.000Z

180

Underground Injection Control Permits and Registrations (Texas) |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

You are here You are here Home » Underground Injection Control Permits and Registrations (Texas) Underground Injection Control Permits and Registrations (Texas) < Back Eligibility Utility Agricultural Investor-Owned Utility State/Provincial Govt Industrial Construction Municipal/Public Utility Local Government Installer/Contractor Rural Electric Cooperative Fuel Distributor Savings Category Buying & Making Electricity Program Info State Texas Program Type Environmental Regulations Safety and Operational Guidelines Provider Texas Commission on Environmental Quality Chapter 27 of the Texas Water Code (the Injection Well Act) defines an "injection well" as "an artificial excavation or opening in the ground made by digging, boring, drilling, jetting, driving, or some other

Note: This page contains sample records for the topic "insar injectivity test" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

LIFAC Sorbent Injection Desulfurization Demonstration Project...  

NLE Websites -- All DOE Office Websites (Extended Search)

of the flue gas in a separate activation reactor, which increases SO 2 removal. An electrostatic precipitator downstream from the point of injection captures the reaction...

182

Blast Furnace Granulated Coal Injection System Demonstration...  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Blast Furnace Granulated Coal Injection System Demonstration Project: A DOE Assessment June 2000 U. S. Department of Energy National Energy Technology Laboratory P.O. Box 880,...

183

Geothermal: Sponsored by OSTI -- Injection through fractures  

Office of Scientific and Technical Information (OSTI)

Injection through fractures Geothermal Technologies Legacy Collection HelpFAQ | Site Map | Contact Us | Admin Log On HomeBasic Search About Publications Advanced Search New Hot...

184

NSLS-II INJECTION STRAIGHT DIAGNOSTICS  

Science Conference Proceedings (OSTI)

The ultra-bright light source being developed by the NSLS-II project will utilize top-up injection and fine tuning of the injection process is mandatory. In this paper we present the diagnostics installed in the injection straight. Its use for commissioning and tuning of the injection cycle is also described. The NSLS-II storage ring will utilize a 9.3 meter long injection straight section shown in Fig. 1. Injection will be preformed with two septa (one pulsed, one DC) and four kickers. The stored beam will be shifted towards the pulsed septum up to IS mm and the nominal distance between centers of the injected and the bumped beam is 9.5mm. The NSLS-II beam position monitors will have turn-by-turn and first-turn capabilities and will be used for the commissioning and tuning the injection process. However, there are three additional BPMs and two beam intercepting OTR screens (flags) installed in the injection straight.

Pinayev, I.; Blednykh, A.; Ferreira, M.; Fliller, R.; Kosciuk, B.; Shaftan, T.V.; Wang, G.

2011-03-28T23:59:59.000Z

185

Powder Injection Molding - Available Technologies - PNNL  

Summary. Presented here is a novel and innovative means of powder injection molding (PIM) of reactive refractory metals, such as titanium and its ...

186

Energy-efficient control in injection molding.  

E-Print Network (OSTI)

??xviii, 209 leaves : ill. ; 30 cm HKUST Call Number: Thesis CENG 2008 Yao As an energy-intensive process, in injection molding, energy cost is (more)

Yao, Ke

2008-01-01T23:59:59.000Z

187

FURNACE INJECTION OF ALKALINE SORBENTS FOR SULFURIC ACID CONTROL  

Science Conference Proceedings (OSTI)

This document summarizes progress on Cooperative Agreement DE-FC26-99FT40718, Furnace Injection of Alkaline Sorbents for Sulfuric Acid Control, during the time period April 1, 2003 through September, 2003. The objective of this project is to demonstrate the use of alkaline reagents injected into the furnace of coal-fired boilers as a means of controlling sulfuric acid emissions. The coincident removal of hydrochloric acid and hydrofluoric acid is also being determined, as is the removal of arsenic, a known poison for NO{sub x} selective catalytic reduction (SCR) catalysts. EPRI, the Tennessee Valley Authority (TVA), FirstEnergy Corporation, American Electric Power (AEP) and the Dravo Lime Company are project co-funders. URS Group is the prime contractor. This is the eighth reporting period for the subject Cooperative Agreement. During previous reporting periods, two long-term sorbent injection tests were conducted, one on Unit 3 at FirstEnergy's Bruce Mansfield Plant (BMP) and one on Unit 1 at AEP's Gavin Plant. Those tests determined the effectiveness of injecting alkaline slurries into the upper furnace of the boiler as a means of controlling sulfuric acid emissions from these units. The alkaline slurries tested included commercially available magnesium hydroxide slurry (Gavin Plant), and a byproduct magnesium hydroxide slurry (both Gavin Plant and BMP). The tests showed that injecting either the commercial or the byproduct magnesium hydroxide slurry could achieve up to 70-75% overall sulfuric acid removal. At BMP, the overall removal was limited by the need to maintain acceptable electrostatic precipitator (ESP) particulate control performance. At Gavin Plant, the overall sulfuric acid removal was limited because the furnace injected sorbent was less effective at removing SO{sub 3} formed across the SCR system installed on the unit for NO{sub x} control than at removing SO{sub 3} formed in the furnace. The SO{sub 3} removal results were presented in the semi-annual Technical Progress Report for the time period April 1, 2001 through September 30, 2001. Additional balance of plant impact information for the two tests was reported in the Technical Progress Report for the time period October 1, 2001 through March 30, 2002. Additional information became available about the effects of byproduct magnesium hydroxide injection on SCR catalyst coupons during the long-term test at BMP, and those results were reported in the report for the time period April 1, 2002 through September 30, 2002. During the current period, process economic estimates were developed, comparing the costs of the furnace magnesium hydroxide slurry injection process tested as part of this project to a number of other candidate SO{sub 3}/sulfuric acid control technologies for coal-fired power plants. The results of this economic evaluation are included in this progress report.

Gary M. Blythe

2003-10-01T23:59:59.000Z

188

Thermal well-test method  

DOE Patents (OSTI)

A well-test method involving injection of hot (or cold) water into a groundwater aquifer, or injecting cold water into a geothermal reservoir. By making temperature measurements at various depths in one or more observation wells, certain properties of the aquifer are determined. These properties, not obtainable from conventional well test procedures, include the permeability anisotropy, and layering in the aquifer, and in-situ thermal properties. The temperature measurements at various depths are obtained from thermistors mounted in the observation wells.

Tsang, Chin-Fu (Albany, CA); Doughty, Christine A. (Berkeley, CA)

1985-01-01T23:59:59.000Z

189

Category:Well Testing Techniques | Open Energy Information  

Open Energy Info (EERE)

following 6 pages are in this category, out of 6 total. E Earth Tidal Analysis F Flow Test I Injectivity Test S Static Temperature Survey Stress Test T Tracer Testing Retrieved...

190

FURNACE INJECTION OF ALKALINE SORBENTS FOR SULFURIC ACID REMOVAL  

Science Conference Proceedings (OSTI)

The objective of this project has been to demonstrate the use of alkaline reagents injected into the furnace of coal-fired boilers as a means of controlling sulfuric acid emissions. The project was co-funded by the U.S. DOE National Energy Technology Laboratory under Cooperative Agreement DE-FC26-99FT40718, along with EPRI, the American Electric Power Company (AEP), FirstEnergy Corporation, the Tennessee Valley Authority, and Carmeuse North America. Sulfuric acid controls are becoming of increased interest for coal-fired power generating units for a number of reasons. In particular, sulfuric acid can cause plant operation problems such as air heater plugging and fouling, back-end corrosion, and plume opacity. These issues will likely be exacerbated with the retrofit of selective catalytic reduction (SCR) for NOX control, as SCR catalysts are known to further oxidize a portion of the flue gas SO{sub 2} to SO{sub 3}. The project tested the effectiveness of furnace injection of four different magnesium-based or dolomitic alkaline sorbents on full-scale utility boilers. These reagents were tested during one- to two-week tests conducted on two FirstEnergy Bruce Mansfield Plant (BMP) units. One of the sorbents tested was a magnesium hydroxide slurry byproduct from a modified Thiosorbic{reg_sign} Lime wet flue gas desulfurization process. The other three sorbents are available commercially and include dolomite, pressure-hydrated dolomitic lime, and commercially available magnesium hydroxide. The dolomite reagent was injected as a dry powder through out-of-service burners. The other three reagents were injected as slurries through air-atomizing nozzles inserted through the front wall of the upper furnace. After completing the four one- to two-week tests, the most promising sorbents were selected for longer-term (approximately 25-day) full-scale tests on two different units. The longer-term tests were conducted to confirm sorbent effectiveness over extended operation on two different boilers, and to determine balance-of-plant impacts. The first long-term test was conducted on FirstEnergy's BMP Unit 3, and the second was conducted on AEP's Gavin Plant, Unit 1. The Gavin Plant test provided an opportunity to evaluate the effects of sorbent injected into the furnace on SO{sub 3} formed across an operating SCR reactor. A final task in the project was to compare projected costs for furnace injection of magnesium hydroxide slurries to estimated costs for other potential sulfuric acid control technologies. Estimates were developed for reagent and utility costs, and capital costs, for furnace injection of magnesium hydroxide slurries and seven other sulfuric acid control technologies. The estimates were based on retrofit application to a model coal-fired plant.

Gary M. Blythe

2004-01-01T23:59:59.000Z

191

Intracluster gas pressure, entropy injection and redshift evolution  

E-Print Network (OSTI)

We study the effect of entropy injection in the intracluster medium (ICM) in light of the recent observationally determined universal pressure profile of the ICM. Beginning with a power-law entropy profile that is expected in the absence of any feedback, we show that a simple universal prescription of entropy injection results in the final, observed universal pressure profile. This simple prescription has two components, one associated with an overall increase in entropy and another associated with injection in the central parts of the cluster. Importantly, both the components of entropy injection are needed to produce the final universal pressure profile. This is indicative of a need of both preheating the ICM as well {\\it in situ} AGN/SNe heating. We demonstrate the usefulness of the method by extending the calculations to clusters at high redshift, and predict redshift evolution of cluster scaling relations that can be tested against data. We show that the self-similar evolution of the universal pressure p...

Nath, Biman B

2011-01-01T23:59:59.000Z

192

New Pellet Injection Schemes on DIII-D  

SciTech Connect

The pellet fueling system on DIII-D has been modified for injection of deuterium pellets from two vertical ports and two inner wall locations on the magnetic high-field side (HFS) of the tokamak. The HFS pellet injection technique was first employed on ASDEX-Upgrade with significant improvements reported in both pellet penetration and fueling efficiency. The new pellet injection schemes on DIII-D required the installation of new guide tubes. These lines are {approx_equal}12.5 m in total length and are made up of complex bends and turns (''roller coaster'' like) to route pellets from the injector to the plasma, including sections inside the torus. The pellet speed at which intact pellets can survive through the curved guide tubes is limited ({approx_equal}200-300 m/s for HFS injection schemes). Thus, one of the three gas guns on the injector was modified to provide pellets in a lower speed regime than the original guns (normal speed range {approx_equal}500 to 1000 m/s). The guide tube installations and gun modifications are described along with the injector operating parameters, and the latest test results are highlighted.

Anderson, P.M.; Baylor, L.R.; Combs, S.K.; Foust, C.R.; Jernigan, T.C.; Robinson, J.I.

1999-11-13T23:59:59.000Z

193

Injection Molding of Plastics from Agricultural Materials  

SciTech Connect

The objective of this research was to conduct a systematic study to relate injection molding parameters to properties of blends of starch and synthetic polymer. From this study, we wished to develop a thorough understanding of the injection molding process and gain significant insight into designing molds and aiding in developing products cheaply and efficiently.

Bhattacharya, M.; Ruan, R.

2001-02-22T23:59:59.000Z

194

Illinois CO2 Injection Project Moves Another Step Forward | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Illinois CO2 Injection Project Moves Another Step Forward Illinois CO2 Injection Project Moves Another Step Forward Illinois CO2 Injection Project Moves Another Step Forward March 15, 2010 - 1:00pm Addthis Washington, DC - The recent completion of a three-dimensional (3-D) seismic survey at a large Illinois carbon dioxide (CO2) injection test site is an important step forward for the carbon capture and storage (CCS) project's planned early 2011 startup. The survey - essential to determine the geometry and internal structures of the deep underground saline reservoir where CO2 will be injected - was completed by the Midwest Geological Sequestration Consortium (MGSC), one of seven regional partnerships created by the U.S. Department of Energy (DOE) to advance CCS technologies nationwide. CCS is seen by many experts as a

195

DOE Regional Partner Initiates CO2 Injection Study in Virginia | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Partner Initiates CO2 Injection Study in Virginia Partner Initiates CO2 Injection Study in Virginia DOE Regional Partner Initiates CO2 Injection Study in Virginia February 11, 2009 - 12:00pm Addthis Washington, D.C. -- A U.S. Department of Energy (DOE) team of regional partners has begun injecting carbon dioxide (CO2) into coal seams in the Central Appalachian Basin to determine the feasibility of CO2 storage in unmineable coal seams and the potential for enhanced coalbed methane recovery. The results of the study will be vital in assessing the potential of carbon storage in coal seams as a safe and permanent method to mitigate greenhouse gas emissions while enhancing production of natural gas. DOE's Southeast Regional Carbon Sequestration Partnership (SECARB) began injecting CO2 at the test site in Russell County, Virginia, in mid January.

196

300 Area Uranium Stabilization Through Polyphosphate Injection: Final Report  

Science Conference Proceedings (OSTI)

The objective of the treatability test was to evaluate the efficacy of using polyphosphate injections to treat uranium-contaminated groundwater in situ. A test site consisting of an injection well and 15 monitoring wells was installed in the 300 Area near the process trenches that had previously received uranium-bearing effluents. This report summarizes the work on the polyphosphate injection project, including bench-scale laboratory studies, a field injection test, and the subsequent analysis and interpretation of the results. Previous laboratory tests have demonstrated that when a soluble form of polyphosphate is injected into uranium-bearing saturated porous media, immobilization of uranium occurs due to formation of an insoluble uranyl phosphate, autunite [Ca(UO2)2(PO4)2nH2O]. These tests were conducted at conditions expected for the aquifer and used Hanford soils and groundwater containing very low concentrations of uranium (10-6 M). Because autunite sequesters uranium in the oxidized form U(VI) rather than forcing reduction to U(IV), the possibility of re-oxidation and subsequent re-mobilization is negated. Extensive testing demonstrated the very low solubility and slow dissolution kinetics of autunite. In addition to autunite, excess phosphorous may result in apatite mineral formation, which provides a long-term source of treatment capacity. Phosphate arrival response data indicate that, under site conditions, the polyphosphate amendment could be effectively distributed over a relatively large lateral extent, with wells located at a radial distance of 23 m (75 ft) reaching from between 40% and 60% of the injection concentration. Given these phosphate transport characteristics, direct treatment of uranium through the formation of uranyl-phosphate mineral phases (i.e., autunite) could likely be effectively implemented at full field scale. However, formation of calcium-phosphate mineral phases using the selected three-phase approach was problematic. Although amendment arrival response data indicate some degree of overlap between the reactive species and thus potential for the formation of calcium-phosphate mineral phases (i.e., apatite formation), the efficiency of this treatment approach was relatively poor. In general, uranium performance monitoring results support the hypothesis that limited long-term treatment capacity (i.e., apatite formation) was established during the injection test. Two separate overarching issues affect the efficacy of apatite remediation for uranium sequestration within the 300 Area: 1) the efficacy of apatite for sequestering uranium under the present geochemical and hydrodynamic conditions, and 2) the formation and emplacement of apatite via polyphosphate technology. In addition, the long-term stability of uranium sequestered via apatite is dependent on the chemical speciation of uranium, surface speciation of apatite, and the mechanism of retention, which is highly susceptible to dynamic geochemical conditions. It was expected that uranium sequestration in the presence of hydroxyapatite would occur by sorption and/or surface complexation until all surface sites have been depleted, but that the high carbonate concentrations in the 300 Area would act to inhibit the transformation of sorbed uranium to chernikovite and/or autunite. Adsorption of uranium by apatite was never considered a viable approach for in situ uranium sequestration in and of itself, because by definition, this is a reversible reaction. The efficacy of uranium sequestration by apatite assumes that the adsorbed uranium would subsequently convert to autunite, or other stable uranium phases. Because this appears to not be the case in the 300 Area aquifer, even in locations near the river, apatite may have limited efficacy for the retention and long-term immobilization of uranium at the 300 Area site..

Vermeul, Vincent R.; Bjornstad, Bruce N.; Fritz, Brad G.; Fruchter, Jonathan S.; Mackley, Rob D.; Newcomer, Darrell R.; Mendoza, Donaldo P.; Rockhold, Mark L.; Wellman, Dawn M.; Williams, Mark D.

2009-06-30T23:59:59.000Z

197

Influence of Thermalisation on Electron Injection in Supernova Remnant Shocks  

E-Print Network (OSTI)

Within a test-particle description of the acceleration process in parallel nonrelativistic shocks, we present an analytic treatment of the electron injection. We estimate the velocity distribution of the injected electrons as the product of the post-shock thermal distribution of electrons times the probability for electrons with a given velocity to be accelerated; the injection efficiency is then evaluated as the integral of this velocity distribution. We estimate the probability of a particle to be injected as that of going back to the upstream region at least once. This is the product of the probability of returning to the shock from downstream times that of recrossing the shock from downstream to upstream. The latter probability is expected to be sensitive to details of the process of electron thermalisation within the (collisionless) shock, a process that is poorly known. In order to include this effect, for our treatment we use results of a numerical, fully kinetic study, by Bykov & Uvarov (1999). According to them, the probability of recrossing depends on physics of thermalisation through a single free parameter (Gamma), which can be expressed as a function of the Mach number of the shock, of the level of electron-ion equilibration, as well as of the spectrum of turbulence. It becomes apparent, from our analysis, that the injection efficiency is related to the post-shock electron temperature, and that it results from the balance between two competing effects: the higher the electron temperature, the higher the fraction of downstream electrons with enough velocity to return to the shock and thus to be ready to cross the shock from downstream to upstream; at the same time, however, the higher the turbulence, which would hinder the crossing.

O. Petruk; R. Bandiera

2006-06-05T23:59:59.000Z

198

Simulating Injectate/Rock Chemical Interaction In Fractured Desert Peak Quartz Monzonite  

DOE Green Energy (OSTI)

Simulations of the interactions of injected fluids with minerals within an engineered fracture in a sample of Desert Peak quartz monzonite were compared with experimental observations of fluid chemistry and fracture permeability. The observed decrease in permeability and effective hydraulic aperture was much more rapid ({approx}1.0 {micro}m/day) for a core injected with a mixed salt solution containing dissolved silica (near-saturation injectate), compared to cores injected with NaCl (far-from-saturation injectate) ({approx}0.1 {micro}m/day). Simulations were in qualitative agreement with these observations. Near-saturation injectate is predicted to result in net precipitation of secondary phases in the fracture ({approx}0.12 {micro}m/day), compared to a net dissolution of the rock for the far-from-saturation injectate ({approx}0.3 {micro}m/day). Permeability loss for the near-saturation-injectate is ascribed to precipitation in the fracture as well as potential dissolution of primary mineral asperities. Permeability loss for the far-from-saturation fluid is ascribed to dissolution of asperities and smoothing of the fracture. Post-test analysis of the fracture surface will be necessary to verify the processes occurring. The simplified geochemical models used do not account for mineral heterogeneity or for distributions of fluid residence times which could be important controls on permeability evolution. Further analysis is planned to explicitly account for these phenomena.

Viani, B; Roberts, J; Detwiler, R; Roberts, S; Carlson, S

2005-06-02T23:59:59.000Z

199

Selection and development of air-injected frit slurry blasting for decontamination of DWPF canisters  

Science Conference Proceedings (OSTI)

Canisters of waste glass produced in the Defense Waste Processing Facility at the Savannah River Plant will be decontaminated by air-injected frit slurry blasting. The byproduct of this operation, contaminated frit slurry, will be used as part of the feed stock for the glass-making process. Therefore, no secondary waste will be created. Scouting tests of four different frit blasting techniques were conducted by the Savannah River Laboratory. The techniques investigated were dry blasting, direct pump slurry blasting, air-aspirated slurry blasting, and air-injected slurry blasting. The air-injected slurry blasting technique was chosen for development, based on results of these scouting tests. A detailed development program was undertaken to optimize the air-injected frit slurry blasting process. 3 references, 28 figures.

Ward, C.R.

1984-09-01T23:59:59.000Z

200

Clean Coal III Project: Blast Furnace Granular Coal Injection Project Trial 1 Report - Blast Furnace Granular Coal Injection - Results with Low Volatile Coal  

SciTech Connect

This report describes the first coal trial test conducted with the Blast Furnace Granular Coal Injection System at Bethlehem Steel Corporation's Burns Harbor Plant. This demonstration project is divided into three phases: Phase I - Design Phase II - Construction Phase III - Operation The design phase was conducted in 1991-1993. Construction of the facility began in August 1993 and was completed in late 1994. The coal injection facility began operating in January 1995 and Phase III began in November 1995. The Trial 1 base test orI C furnace was carried out in October 1996 as a comparison period for the analysis of the operation during subsequent coal trials.

1997-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "insar injectivity test" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Drilling Waste Management Fact Sheet: Slurry Injection of Drilling Wastes  

NLE Websites -- All DOE Office Websites (Extended Search)

Slurry Injection Slurry Injection Fact Sheet - Slurry Injection of Drilling Wastes Underground Injection of Drilling Wastes Several different approaches are used for injecting drilling wastes into underground formations for permanent disposal. Salt caverns are described in a separate fact sheet. This fact sheet focuses on slurry injection technology, which involves grinding or processing solids into small particles, mixing them with water or some other liquid to make a slurry, and injecting the slurry into an underground formation at pressures high enough to fracture the rock. The process referred to here as slurry injection has been given other designations by different authors, including slurry fracture injection (this descriptive term is copyrighted by a company that provides slurry injection services), fracture slurry injection, drilled cuttings injection, cuttings reinjection, and grind and inject.

202

Integrated injection-locked semiconductor diode laser  

DOE Patents (OSTI)

A continuous wave integrated injection-locked high-power diode laser array is provided with an on-chip independently-controlled master laser. The integrated injection locked high-power diode laser array is capable of continuous wave lasing in a single near-diffraction limited output beam at single-facet power levels up to 125 mW (250 mW total). Electronic steering of the array emission over an angle of 0.5 degrees is obtained by varying current to the master laser. The master laser injects a laser beam into the slave array by reflection of a rear facet. 18 figures.

Hadley, G.R.; Hohimer, J.P.; Owyoung, A.

1991-02-19T23:59:59.000Z

203

Integrated injection-locked semiconductor diode laser  

DOE Patents (OSTI)

A continuous wave integrated injection-locked high-power diode laser array is provided with an on-chip independently-controlled master laser. The integrated injection locked high-power diode laser array is capable of continuous wave lasing in a single near-diffraction limited output beam at single-facet power levels up to 125 mW (250 mW total). Electronic steering of the array emission over an angle of 0.5 degrees is obtained by varying current to the master laser. The master laser injects a laser beam into the slave array by reflection of a rear facet.

Hadley, G. Ronald (Albuquerque, NM); Hohimer, John P. (Albuquerque, NM); Owyoung, Adelbert (Albuquerque, NM)

1991-01-01T23:59:59.000Z

204

Alkaline sorbent injection for mercury control  

DOE Patents (OSTI)

A mercury removal system for removing mercury from combustion flue gases is provided in which alkaline sorbents at generally extremely low stoichiometric molar ratios of alkaline earth or an alkali metal to sulfur of less than 1.0 are injected into a power plant system at one or more locations to remove at least between about 40% and 60% of the mercury content from combustion flue gases. Small amounts of alkaline sorbents are injected into the flue gas stream at a relatively low rate. A particulate filter is used to remove mercury-containing particles downstream of each injection point used in the power plant system.

Madden, Deborah A. (Boardman, OH); Holmes, Michael J. (Washington Township, Stark County, OH)

2003-01-01T23:59:59.000Z

205

Alkaline sorbent injection for mercury control  

DOE Patents (OSTI)

A mercury removal system for removing mercury from combustion flue gases is provided in which alkaline sorbents at generally extremely low stoichiometric molar ratios of alkaline earth or an alkali metal to sulfur of less than 1.0 are injected into a power plant system at one or more locations to remove at least between about 40% and 60% of the mercury content from combustion flue gases. Small amounts of alkaline sorbents are injected into the flue gas stream at a relatively low rate. A particulate filter is used to remove mercury-containing particles downstream of each injection point used in the power plant system.

Madden, Deborah A. (Boardman, OH); Holmes, Michael J. (Washington Township, Stark County, OH)

2002-01-01T23:59:59.000Z

206

Injection of Electrons and Holes into Nanostructures  

NLE Websites -- All DOE Office Websites (Extended Search)

Injection of Electrons and Holes into Nanostructures Injection of Electrons and Holes into Nanostructures This program targets fundamental understanding of nanoscale charge transfer processes. The proposed work draws on the strengths of the Brookhaven Chemistry Department in the areas of electron transfer experiment and theory, and extends the area of inquiry to nanoscale processes. Electron/hole injection into a wire, a nanocrystal, a nanotube or other nanostructure in solution may be brought about by light absorption, by an electron pulse (pulse radiolysis, LEAF), by a chemical reagent, or through an electrode. These processes are being studied by transient methods by following conductivity, current, but most generally, spectroscopic changes in the solutions to determine the dynamics of charge injection. The observed transient spectra can also provide values for electron-transfer coupling elements and energetics. Theoretical/computational studies can help in materials design and in the interpretation of the experimental results. The experimental systems being examined include molecular wires and metal nanoclusters.

207

Studies of injection into naturally fractured reservoirs  

DOE Green Energy (OSTI)

A semi-analytical model for studies of cold water injection into naturally fractured reservoirs has been developed. The model can be used to design the flow rates and location of injection wells in such systems. The results obtained using the model show that initially the cold water will move very rapidly through the fracture system away from the well. Later on, conductive heat transfer from the rock matrix blocks will retard the advancement of the cold water front, and eventually uniform energy sweep conditions will prevail. Where uniform energy sweep conditions are reached the cold waer movement away from the injection well will be identical to that in a porous medium; consequently maximum energy recovery from the rock matrix will be attained. The time of uniform energy sweep and the radial distance from the injection well where it occurs are greatly dependent upon the fracture spacing, but independent of the fracture aperture.

Boedvarsson, G.S.; Lai, C.H.

1982-10-01T23:59:59.000Z

208

Efficient Spin Injection using Tunnel Injectors  

Science Conference Proceedings (OSTI)

Semiconductor spintronics aims to develop novel sensor, memory and logic devices by manipulating the spin states of carriers in semiconducting materials. This talk will focus on electrical spin injection into semiconductors, which is a prerequisite for ...

Xin Jiang

2005-07-01T23:59:59.000Z

209

Fluidized bed injection assembly for coal gasification  

DOE Patents (OSTI)

A coaxial feed system for fluidized bed coal gasification processes including an inner tube for injecting particulate combustibles into a transport gas, an inner annulus about the inner tube for injecting an oxidizing gas, and an outer annulus about the inner annulus for transporting a fluidizing and cooling gas. The combustibles and oxidizing gas are discharged vertically upward directly into the combustion jet, and the fluidizing and cooling gas is discharged in a downward radial direction into the bed below the combustion jet.

Cherish, Peter (Bethel Park, PA); Salvador, Louis A. (Hempfield Township, Westmoreland County, PA)

1981-01-01T23:59:59.000Z

210

Direct liquid injection of liquid petroleum gas  

SciTech Connect

A fuel injector and injection system for injecting liquified petroleum gas (LPG) into at least one air/fuel mixing chamber from a storage means that stores pressurized LPG in its liquid state. The fuel injector (including a body), adapted to receive pressurized LPG from the storage means and for selectively delivering the LPG to the air/fuel mixing chamber in its liquified state. The system including means for correcting the injector activation signal for pressure and density variations in the fuel.

Lewis, D.J.; Phipps, J.R.

1984-02-14T23:59:59.000Z

211

Experimental study of Morichal heavy oil recovery using combined steam and propane injection  

E-Print Network (OSTI)

Considerable research and testing have been conducted for the improvement of basic thermal recovery processes and for the development and application of other methods of reservoir heating. Effects of various additives injected simultaneously with steam (for the purpose of increasing steam recovery efficiency) are being evaluated. An experimental study has been performed to investigate the effect of combined steam and propane injection on recovery of heavy oil from the Morichal field, Venezuela. The experiments were conducted using an injection cell packed with sandmix containing a mixture of sand, water, and Morichal oil. Experimental runs involved injection of steam, or propane, or a mixture of steam and propane into the cell at constant rate, temperature, and pressure. The injection was kept constant at 5 g/min for all runs. Five experiments were performed, namely, run 1 (50 wt.% steam and 50 wt.% propane), run 2 (100 wt.% steam), run 3 (75 wt.% steam and 25 wt.% propane), run 4 (100 wt.% propane), and run 5 (95 wt.% steam and 5 wt.% propane). Main findings for this study are as follows. First, it appears possible to accelerate recovery of Morichal oil using combined steam and propane injection. Oil recovery at 61% OOIP may be up to 0.23 pore volume faster than using steam injection alone, with gain in ultimate recovery of up to 5% OOIP. Second, with only propane injection, at temperature and pressure conditions tested, practically no oil is recovered. Steam is necessary to reduce interfacial tension and the oil viscosity, thus allowing propane to permeate through the oil. This increases propane miscibility with oil, further reducing the residual oil saturation, and enhances the displacement efficiency. It is recommended that further research be conducted to confirm the technical and economic feasibility of steam-propane injection, particularly for other crude oil types, and at pressure and temperature conditions encountered in the field.

Goite Marcano, Jose Gregorio

1999-01-01T23:59:59.000Z

212

Tracer testing at Soultz-sous-Forts (France) using naphthalene  

E-Print Network (OSTI)

: · EPS1 fully cored exploration · GPK-1 preliminary injection tests · GPK-3 injection well · GPK-2 and future GPK-4 production wells 3.6 km continuous logs: Caliper, Spectral GR, UBI (5100m) #12;EHDRA-2 (July 2000) > Water injection · 26,800 m3 of fresh water and 1,000 m3 of heavy brine > Tracer

213

Cerro Prieto cold water injection: effects on nearby production wells  

E-Print Network (OSTI)

reservoir wells close to injection well E-6 along with theMeeting. Most of the injection wells are open to the Alphaand completing new injection wells is lower than in the East

Truesdell, A.H.

2010-01-01T23:59:59.000Z

214

Thermal signature reduction through liquid nitrogen and water injection  

E-Print Network (OSTI)

The protection of aircraft against shoulder fired heat seeking missiles is of growing concern in the aviation community. This thesis presents a simple method for shielding the infrared signature of a jet engine from heat seeking missiles. The research efforts investigated two approaches to shield the thermal signature of the Noel Penny Type 401 turbojet at the Texas A&M University Propulsion Lab Test Cell. First, liquid nitrogen was injected through a manifold at a flow rate equivalent to the flow rate of exhaust gases, producing a small temperature reduction in the exhaust but no infrared shielding. Second, water was injected at a flow rate of 13% of the flow of exhaust gases, producing a greater temperature reduction and some shielding. Water was then injected through a manifold at a ?ow rate of 118% of the flow rate of exhaust gases, producing a substantial reduction in temperature and complete shielding of the infrared signature. Additionally, numerical simulations were performed using FLUENT to support these experiments. Results are presented in the form of thermocouple data and thermal images from the experiments, and in the form of temperature contours and streamtraces from the simulations.

Guarnieri, Jason Antonio

2004-12-01T23:59:59.000Z

215

U-058: Apache Struts Conversion Error OGNL Expression Injection...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

8: Apache Struts Conversion Error OGNL Expression Injection Vulnerability U-058: Apache Struts Conversion Error OGNL Expression Injection Vulnerability December 12, 2011 - 9:00am...

216

Calculating the probability of injected carbon dioxide plumes encountering faults  

E-Print Network (OSTI)

Change Special Report on Carbon Dioxide Capture and Storage,Probability of Injected Carbon Dioxide Plumes Encounteringthe probability of injected carbon dioxide encountering and

Jordan, P.D.

2013-01-01T23:59:59.000Z

217

Texas Natural Gas Injections into Underground Storage (Million...  

Gasoline and Diesel Fuel Update (EIA)

View History: Monthly Annual Download Data (XLS File) Texas Natural Gas Injections into Underground Storage (Million Cubic Feet) Texas Natural Gas Injections into Underground...

218

Idaho Natural Gas Underground Storage Injections All Operators...  

Gasoline and Diesel Fuel Update (EIA)

Underground Storage Injections All Operators (Million Cubic Feet) Idaho Natural Gas Underground Storage Injections All Operators (Million Cubic Feet) Decade Year-0 Year-1 Year-2...

219

Connecticut Natural Gas Underground Storage Injections All Operators...  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Injections All Operators (Million Cubic Feet) Connecticut Natural Gas Underground Storage Injections All Operators (Million Cubic Feet) Decade Year-0 Year-1...

220

Alaska Natural Gas Underground Storage Injections All Operators...  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Injections All Operators (Million Cubic Feet) Alaska Natural Gas Underground Storage Injections All Operators (Million Cubic Feet) Decade Year-0 Year-1 Year-2...

Note: This page contains sample records for the topic "insar injectivity test" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Delaware Natural Gas Underground Storage Injections All Operators...  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Injections All Operators (Million Cubic Feet) Delaware Natural Gas Underground Storage Injections All Operators (Million Cubic Feet) Decade Year-0 Year-1 Year-2...

222

Wisconsin Natural Gas Underground Storage Injections All Operators...  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Injections All Operators (Million Cubic Feet) Wisconsin Natural Gas Underground Storage Injections All Operators (Million Cubic Feet) Decade Year-0 Year-1...

223

Georgia Natural Gas Underground Storage Injections All Operators...  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Injections All Operators (Million Cubic Feet) Georgia Natural Gas Underground Storage Injections All Operators (Million Cubic Feet) Decade Year-0 Year-1 Year-2...

224

New Jersey Natural Gas Underground Storage Injections All Operators...  

U.S. Energy Information Administration (EIA) Indexed Site

Pages: Injections of Natural Gas into Underground Storage - All Operators New Jersey Underground Natural Gas Storage - All Operators Injections of Natural Gas into Storage...

225

South Carolina Natural Gas Underground Storage Injections All...  

U.S. Energy Information Administration (EIA) Indexed Site

Pages: Injections of Natural Gas into Underground Storage - All Operators South Carolina Underground Natural Gas Storage - All Operators Injections of Natural Gas into Storage...

226

North Carolina Natural Gas Underground Storage Injections All...  

U.S. Energy Information Administration (EIA) Indexed Site

Pages: Injections of Natural Gas into Underground Storage - All Operators North Carolina Underground Natural Gas Storage - All Operators Injections of Natural Gas into Storage...

227

Illinois Natural Gas Injections into Underground Storage (Million...  

Gasoline and Diesel Fuel Update (EIA)

Injections into Underground Storage (Million Cubic Feet) Illinois Natural Gas Injections into Underground Storage (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct...

228

Epidemiology of HIV Among Injecting and Non-injecting Drug Users: Current Trends and Implications for Interventions  

E-Print Network (OSTI)

might inject drugs worldwide [1]. China, the United States,China, the United States, and Russia, the three leading countries for injecting drugChina Russia USA Fig. 1 Number and proportion of HIV infection among injecting drug

Strathdee, Steffanie A.; Stockman, Jamila K.

2010-01-01T23:59:59.000Z

229

Model study of historical injection in the Southeast Geysers  

DOE Green Energy (OSTI)

A three component model study of the historical injection of two wells in the Unit 13 area demonstrates that the recovery of injection derived steam is influenced by the geologic structure of the bottom of the reservoir and the relative location of injection wells. the migration of injectate from the first injection well, located up structure from the second, quenched the area around the second injector before it started operation. while both wells had similar cumulative mass injected, nearly five times more injection derived steam is recovered from the first injector than the second. Sensitivity runs were made to three cases of increasing matrix capillary pressure. The recovery of injection derived steam increases with higher values of capillarity. The interaction of structure at the bottom of the reservoir, injection well locations, and matrix capillarity all influence the recovery efficiency of injectate as steam. The model developed in this study will be used to evaluate injection strategies at The Geysers.

Faulder, D.D.

1992-01-01T23:59:59.000Z

230

Model study of historical injection in the southeast Geysers  

DOE Green Energy (OSTI)

A three component model study of the historical injection of two wells in the Unit 13 area demonstrates that the recovery of injection derived steam is influenced by the geologic structure of the bottom of the reservoir and the relative location of injection wells. The migration of injectate from the first injection well, located up structure from the second, quenched the area around the second injector before it started operation. While both wells had similar cumulative mass injected, nearly five times more injection derived steam is recovered from the first injector than the-second. Sensitivity runs were made to three cases of increasing matrix capillary pressure. The recovery of injection derived steam increases with higher values of capillarity. The interaction of structure at the bottom of the reservoir, injection well locations, and matrix capillarity all influence the recovery efficiency of injected as steam. The model developed in this study will be used to evaluate injection strategies at The Geysers.

Faulder, D.D.

1992-08-01T23:59:59.000Z

231

Model study of historical injection in the southeast Geysers  

DOE Green Energy (OSTI)

A three component model study of the historical injection of two wells in the Unit 13 area demonstrates that the recovery of injection derived steam is influenced by the geologic structure of the bottom of the reservoir and the relative location of injection wells. The migration of injectate from the first injection well, located up structure from the second, quenched the area around the second injector before it started operation. While both wells had similar cumulative mass injected, nearly five times more injection derived steam is recovered from the first injector than the-second. Sensitivity runs were made to three cases of increasing matrix capillary pressure. The recovery of injection derived steam increases with higher values of capillarity. The interaction of structure at the bottom of the reservoir, injection well locations, and matrix capillarity all influence the recovery efficiency of injected as steam. The model developed in this study will be used to evaluate injection strategies at The Geysers.

Faulder, D.D.

1992-01-01T23:59:59.000Z

232

DOE Regional Partnership Initiates CO2 Injection in Lignite Coal Seam |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Initiates CO2 Injection in Lignite Coal Initiates CO2 Injection in Lignite Coal Seam DOE Regional Partnership Initiates CO2 Injection in Lignite Coal Seam March 10, 2009 - 1:00pm Addthis Washington, DC -- A U.S. Department of Energy/National Energy Technology Laboratory (NETL) team of regional partners has begun injecting CO2 into a deep lignite coal seam in Burke County, North Dakota, to demonstrate the economic and environmental viability of geologic CO2 storage in the U.S. Great Plains region. Ultimately, geologic carbon sequestration is expected to play an important role in mitigating greenhouse gas emissions and combating climate change. The Lignite Field Validation Test is being conducted by the Plains CO2 Reduction (PCOR) Partnership, one of seven regional partnerships under DOE's Regional Carbon Sequestration Partnership Program. The seven

233

Characteristics of Microseismicity in the DV11 Injection Area, Southeast Geysers, California  

DOE Green Energy (OSTI)

Microearthquake (MEQ) occurrence surrounding the injection well DV11 in Unit 18 of the Southeast (SE) Geysers is investigated. Seismicity rates are compared to the injection rate, and to flow rates in nearby steam extraction wells, which were monitored during the Unit 18 Cooperative Injection Test in 1994 and 1995. The seismicity rate is seen to mirror both injection and production rates, although a time lag sometimes occurs. Waveform cross-correlation is performed for the MEQs in the DV11 area, and the events grouped into clusters based on waveform similarity. Relative location techniques applied to the events in two of these clusters show 7 events grouped into a volume of about 25 m in diameter, at an elevation of about -0.65 km msl and 5 events grouped into a vertically-oriented linear feature about 100 m in length, at about -1.8 km msl.

Kirkpatrick, Ann; Peterson Jr., John E.; Majer, Ernest L.; Nadeau, Robe rt

1998-11-01T23:59:59.000Z

234

Testing of java web services for robustness  

Science Conference Proceedings (OSTI)

This paper presents a new compile-time analysis that enables a testing methodology for white-box coverage testing of error recovery code (i.e., exception handlers) in Java web services using compiler-directed fault injection. The analysis allows compiler-generated ... Keywords: def-use testing, exceptions, java, test coverage metrics

Chen Fu; Barbara G. Ryder; Ana Milanova; David Wonnacott

2004-07-01T23:59:59.000Z

235

Assessment of Injection Well Construction and Operation for Water Injection Wells and Salt Water Disposal Wells  

E-Print Network (OSTI)

Assessment of Injection Well Construction and Operation for Water Injection Wells and Salt Water Disposal Wells in the Nine Township Area ­ 2009 September 2009 Prepared by Delaware Basin Drilling from EPA to DOE dated 7/16/2009) 1 Solution Mining Practices 1 Recent Well Failures 2 The Mechanism

236

Interaction between Injection Points during Hydraulic Fracturing  

E-Print Network (OSTI)

We present a model of the hydraulic fracturing of heterogeneous poroelastic media. The formalism is an effective continuum model that captures the coupled dynamics of the fluid pressure and the fractured rock matrix and models both the tensile and shear failure of the rock. As an application of the formalism, we study the geomechanical stress interaction between two injection points during hydraulic fracturing (hydrofracking) and how this interaction influences the fracturing process. For injection points that are separated by less than a critical correlation length, we find that the fracturing process around each point is strongly correlated with the position of the neighboring point. The magnitude of the correlation length depends on the degree of heterogeneity of the rock and is on the order of 30-45 m for rocks with low permeabilities. In the strongly correlated regime, we predict a novel effective fracture-force that attracts the fractures toward the neighboring injection point.

Hals, Kjetil M D

2012-01-01T23:59:59.000Z

237

Energy Injection in GRB Afterglow Models  

E-Print Network (OSTI)

We extend the standard fireball model, widely used to interpret gamma-ray burst (GRB) afterglow light curves, to include energy injections, and apply the model to the afterglow light curves of GRB 990510, GRB 000301C and GRB 010222. We show that discrete energy injections can cause temporal variations in the optical light curves and present fits to the light curves of GRB 000301C as an example. A continuous injection may be required to interpret other bursts such as GRB 010222. The extended model accounts reasonably well for the observations in all bands ranging from X-rays to radio wavelengths. In some cases, the radio light curves indicate that additional model ingredients may be needed.

Gudlaugur Johannesson; Gunnlaugur Bjornsson; Einar H. Gudmundsson

2006-05-11T23:59:59.000Z

238

A study on Raman Injection Laser  

E-Print Network (OSTI)

The Raman Injection Laser is a new type of laser which is based on triply resonant stimulated Raman scattering between quantum confined states within the active region of a Quantum Cascade Laser that serves as an internal optical pump. The Raman Injection Laser is driven electrically and no external laser pump is required. Triple resonance leads to an enhancement of orders of magnitude in the Raman gain, high conversion efficiency and low threshold. We studied this new type of laser and conclude some basic equations. With reasonable experimental parameters, we calculated the laser gain, losses and the output power of the Raman Injection Laser by using Mathematica and FEMLab. Finally we compared the theoretical and experimental results.

Liu, Debin

2005-08-01T23:59:59.000Z

239

Optimization of Trona/Limestone Injection for SO2 Control in Coal-Fired Boilers  

SciTech Connect

Mobotec USA develops and markets air pollution control systems for utility boilers and other combustion systems. They have a particular interest in technologies that can reduce NOx, SOx, and mercury emissions from coal-fired boilers, and have been investigating the injection of sorbents such as limestone and trona into a boiler to reduce SOx and Hg emissions. WRI proposed to use the Combustion Test Facility (CTF) to enable Mobotec to conduct a thorough evaluation of limestone and trona injection for SO{sub 2} control. The overall goal of the project was to characterize the SO{sub 2} reductions resulting from the injection of limestone and trona into the CTF when fired with a high-sulfur eastern bituminous coal used in one of Mobotec's Midwest installations. Results revealed that when limestone was injected at Ca:S molar ratios of 1.5 to 3.0, the resulting SO{sub 2} reductions were 35-55%. It is believed that further reductions can be attained with improved mixing of the sorbent with the combustion gases. When limestone was added to the coal, at Ca:S molar ratios of 0.5 to 1.5, the SO{sub 2} reductions were 13-21%. The lower reductions were attributed to dead-burning of the sorbent in the high temperature flame zone. In cases where limestone was both injected into the furnace and added to the coal, the total SO{sub 2} reductions for a given Ca:S molar ratio were similar to the reductions for furnace injection only. The injection of trona into the mid-furnace zone, for Na:S molar ratios of 1.4 to 2.4, resulted in SO{sub 2} reductions of 29-43%. Limestone injection did not produce any slag deposits on an ash deposition probe while trona injection resulted in noticeable slag deposition.

None

2005-09-01T23:59:59.000Z

240

Neutral beam injection in 2XIIB  

SciTech Connect

Integrated into the operation of the 2XIIB controlled fusion experiment is a 600-A, 20-keV neutral injection system: the highest neutral-beam current capacity of any existing fusion machine. This paper outlines the requirements of the injection system and the design features to which they led. Both mechanical and electrical aspects are discussed. Also included is a brief description of some operational aspects of the system and some of the things we have learned along the way, as well as a short history of the most significant developments. (auth)

Hibbs, S.M.

1975-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "insar injectivity test" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Injected Beam Dynamics in SPEAR3  

SciTech Connect

For the top-off operation it is important to understand the time evolution of charge injected into the storage ring. The large-amplitude horizontal oscillation quickly filaments and decoheres, and in some cases exhibits non-linear x-y coupling before damping to the stored orbit. Similarly, in the longitudinal dimension, any mismatch in beam arrival time, beam energy or phase-space results in damped, non-linear synchrotron oscillations. In this paper we report on measurements of injection beam dynamics in the transverse and longitudinal planes using turn-by-turn BPMs, a fast-gated, image-intensified CCD camera and a Hamamatsu C5680 streak camera.

Corbett, Jeff; /SLAC; Fisher, Alan; /SLAC; Huang, Xiaobiao; /SLAC; Safranek, James; /SLAC; Westerman, Stuart; /SLAC; Cheng, Weixing; /Brookhaven; Mok, Walter; /Unlisted

2012-06-21T23:59:59.000Z

242

Mixed Mode Fuel Injector And Injection System  

DOE Patents (OSTI)

A fuel injector includes a homogenous charge nozzle outlet set and a conventional nozzle outlet set that are controlled respectively by first and second three way needle control valves. Each fuel injector includes first and second concentric needle valve members. One of the needle valve members moves to an open position for a homogenous charge injection event, while the other needle valve member moves to an open position for a conventional injection event. The fuel injector has the ability to operate in a homogenous charge mode with a homogenous charge spray pattern, a conventional mode with a conventional spray pattern or a mixed mode.

Stewart, Chris Lee (Normal, IL); Tian, Ye (Bloomington, IL); Wang, Lifeng (Normal, IL); Shafer, Scott F. (Morton, IL)

2005-12-27T23:59:59.000Z

243

Interphase power controller with voltage injection  

Science Conference Proceedings (OSTI)

This paper introduces a new family of Interphase Power Controllers (IPC) based on the principle of voltage injection commonly used in phase-shifting transformers (PST). The voltage injection IPC exhibits power (active and reactive) control characteristics similar to previously defined IPC's and retains their inherent qualities: passive control, short circuit limitation and voltage decoupling. It also provides more flexibility for the adjustment of the operating points. Two promising topologies are described in more detail. One of them offers the potential of retrofitting existing phase-shifting transformers into full-fledged IPC's.

Beauregard, F.; Brochu, J.; Morin, G.; Pelletier, P. (Centre d'Innovation sur le Transport d'Energie du Quebec, Varennes, Quebec (Canada))

1994-10-01T23:59:59.000Z

244

Non-isothermal CO2 flow through an injection well  

E-Print Network (OSTI)

Non-isothermal CO2 flow through an injection well Orlando SilvaOrlando Silva #12; The Problem CO2 or gas injection well Questions Injection of scCO2 vs. gaseous CO2. Other relevant examples: - gas and therefore the CO2 injection rate. caprock reservoir geothermal gradient hydrostatic gradient well CO2 bubble

Politècnica de Catalunya, Universitat

245

Discussion on Cycle Water Injection Effect and Its Influencing Factors  

Science Conference Proceedings (OSTI)

Cyclic waterflooding is a kind of waterflood technique, which can improve the waterflood efficiency in low-permeability and fracture-porosity reservoir by changing periodically injected water volume. This article gives the principle and the applied conditions ... Keywords: water flooding, principle, the opportunity of water injection, water injection efficiency, water injection period

Shan Wuyi, Zhang Xue

2013-06-01T23:59:59.000Z

246

Diesel engine emissions reduction by multiple injections having increasing pressure  

DOE Patents (OSTI)

Multiple fuel charges are injected into a diesel engine combustion chamber during a combustion cycle, and each charge after the first has successively greater injection pressure (a higher injection rate) than the prior charge. This injection scheme results in reduced emissions, particularly particulate emissions, and can be implemented by modifying existing injection system hardware. Further enhancements in emissions reduction and engine performance can be obtained by using known measures in conjunction with the invention, such as Exhaust Gas Recirculation (EGR).

Reitz, Rolf D. (Madison, WI); Thiel, Matthew P. (Madison, WI)

2003-01-01T23:59:59.000Z

247

Tracer Testing | Open Energy Information  

Open Energy Info (EERE)

Tracer Testing Tracer Testing Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: Tracer Testing Details Activities (9) Areas (5) Regions (0) NEPA(0) Exploration Technique Information Exploration Group: Downhole Techniques Exploration Sub Group: Well Testing Techniques Parent Exploration Technique: Well Testing Techniques Information Provided by Technique Lithology: Stratigraphic/Structural: Fracture zones and formation permeability Hydrological: Flow rates, flow direction, hydrologic connections, storativity Thermal: Dictionary.png Tracer Testing: A method based on injecting chemical tracers into the reservoir and monitoring how long it takes and where those tracers travel. The purpose is to model subsurface hydrothermal flow characteristics.

248

Passive safety injection system using borated water  

DOE Patents (OSTI)

A passive safety injection system relies on differences in water density to induce natural circulatory flow patterns which help maintain prescribed concentrations of boric acid in borated water, and prevents boron from accumulating in the reactor vessel and possibly preventing heat transfer.

Conway, Lawrence E. (Allegheny, PA); Schulz, Terry L. (Westmoreland, PA)

1993-01-01T23:59:59.000Z

249

Type-checking injective pure type systems  

Science Conference Proceedings (OSTI)

Injective pure type systems form a large class of pure type systems for which one can compute by purely syntactic means two sorts elmt(?∣M) and sort(?∣M), where ? is a pseudo-context and M is a pseudo-term, ...

Gilles Barthe

1999-11-01T23:59:59.000Z

250

Definition: Tracer Testing | Open Energy Information  

Open Energy Info (EERE)

Jump to: navigation, search Dictionary.png Tracer Testing A method based on injecting chemical tracers into the reservoir and monitoring how long it takes and where those tracers...

251

Thermal well-test method  

DOE Patents (OSTI)

A well-test method involving injection of hot (or cold) water into a groundwater aquifer, or injecting cold water into a geothermal reservoir is disclosed. By making temperature measurements at various depths in one or more observation wells, certain properties of the aquifer are determined. These properties, not obtainable from conventional well test procedures, include the permeability anisotropy, and layering in the aquifer, and in-situ thermal properties. The temperature measurements at various depths are obtained from thermistors mounted in the observation wells.

Tsang, C.F.; Doughty, C.A.

1984-02-24T23:59:59.000Z

252

Coal combustion under conditions of blast furnace injection; [Quarterly] technical report, September 1--November 30, 1993  

SciTech Connect

A potentially new use for Illinois coal is its use as a fuel injected into a blast furnace to produce molten iron as the first step in steel production. Because of its increasing cost and decreasing availability, metallurgical coke is now being replaced by coal injected at the tuyere area of the furnace where the blast air enters. The purpose of this study is to evaluate the combustion of coal during the blast furnace injection process and to delineate the optimum properties of the feed coal. This investigation is significant to the use of Illinois coal in that the limited research to date suggests that coals of low fluidity and moderate to high sulfur and chlorine contents are suitable feedstocks for blast furnace injection. This study is unique in that it will be the first North American effort to directly determine the nature of the combustion of coal injected into a blast furnace. This proposal is a follow-up to one funded for the 1992--1993 period. It is intended to complete the study already underway with the Armco Inc. steel company and to initiate a new cooperative study along somewhat similar lines with the Inland Steel Company. The results of this study will lead to the development of a testing and evaluation protocol that will give a unique and much needed understanding of the behavior of coal in the injection process and prove the potential of Illinois coals f or such use.

Crelling, J.C.

1993-12-31T23:59:59.000Z

253

Study Reveals Fuel Injection Timing Impact on Particle Number Emissions (Fact Sheet)  

DOE Green Energy (OSTI)

Start of injection can improve environmental performance of fuel-efficient gasoline direct injection engines.

Not Available

2012-12-01T23:59:59.000Z

254

Optimizing injected solvent fraction in stratified reservoirs  

E-Print Network (OSTI)

Waterflooding has become standard practice for extending the productive life of many solution gas drive reservoirs, but has the disadvantage of leaving a substantial residual oil volume in the reservoir. Solvent flooding has been offered as a method whereby oil may be completely displaced from the reservoir, leaving no residual volume. Field results have demonstrated that solvent floods suffer from early solvent breakthrough and considerable oil by-passing owing to high solvent mobility. The injection of both water and solvent has been demonstrated to offer advantages. Water partially mitigates both the adverse mobility and high cost of solvent floods, while solvent mobilizes oil which would be left in the reservoir by water alone. The process is equally applicable to reservoirs currently at residual oil saturation (tertiary floods) and to reservoirs at maximum oil saturation (secondary floods). In stratified reservoirs high permeability layers may be preferentially swept by solvent floods, while low permeability layers may be scarcely swept at all. Presence or absence of transverse communication between layers can modify overall sweep efficiency. This work is a study of water-solvent injection in stratified reservoirs based on computer simulation results. Fractional oil recovery as a function of injected solvent fraction, permeability contrast between layers, initial oil saturation, and presence or absence of transverse communication between strata has been determined. Results are presented as a series of optimization curves. Permeability contrast between layers is shown to be the dominant control on fractional oil recovery. Transverse communicating reservoirs are shown to require a higher solvent-water ratio in order to attain recoveries comparable to transverse noncommunicating reservoirs. In actual field projects, water and solvent are injected alternately as discrete slugs. This process is known as "WAG" for "water-alternating-gas". In the simulations used in this study, continuous water-solvent injection at a fixed fraction rather than true WAG was employed. It is demonstrated that the two methods give equivalent results. In summary, this work is the first comprehensive study of the behavior of stratified reservoirs undergoing water-solvent injection.

Moon, Gary Michael

1993-01-01T23:59:59.000Z

255

[Martin high pressure common rail diesel engine injection system]. Technical progress report, August--October 1995  

DOE Green Energy (OSTI)

We have a contract with Diesel Recerche of Trieste, Italy, and the Fincantier Group in Italy. They are naval ship builders. Our contract is to work with Diesel Recerche to design the `Martin` fuel injection system for their first test engine for a naval ship. Tiby Martin has been working in the design and detailed layout of the application drawings for Diesel Recerche.

NONE

1995-12-01T23:59:59.000Z

256

Research on the Performance and Emission of a Port Fuel Injection Hydrogen Internal Combustion Engine  

Science Conference Proceedings (OSTI)

A 2.0L nature aspirate gasoline engine was modified to port fuel injection (PFI) hydrogen internal combustion engine (HICE) and a series dynamometer tests were carried out. The in-cylinder combustion process was analyzed, the performance, thermal efficiency ... Keywords: hydrogen ICE, performance, emission, combustion characteristics

Dawei Sun; Fushui Liu

2011-02-01T23:59:59.000Z

257

Research on the Performance and Emission of a Port Fuel Injection Hydrogen Internal Combustion Engine  

Science Conference Proceedings (OSTI)

A 2.0L nature aspirate gasoline engine was modified to port fuel injection (PFI) hydrogen internal combustion engine (HICE) and a series dynamometer tests were carried out. The in-cylinder combustion process was analyzed, the performance, thermal efficiency ... Keywords: hydrogen ICE, performance, emission, combustion characteristics

Dawei Sun; Fushui Liu

2010-12-01T23:59:59.000Z

258

trona test report summary 1-17-06 .doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1 of 5 1 of 5 Trona Injection Tests Mirant Potomac River Station Unit 1 November 12 to December 23, 2005 Summary Report Mirant Corporation January 17, 2006 Page 2 of 5 1. INTRODUCTION Trona injection tests were conducted at Mirant's Potomac River Station on Unit 1 between November 12 and December 23, 2005. The purpose of these tests was to determine the capability of dry injection of trona to achieve substantial SO 2 removal from the stack discharge, and the determination of other operating impacts from the trona injection, if any. Temporary trona injection equipment was installed on Unit 1, to inject dry trona in the duct between the boiler economizer outlet and the hot precipitator inlet. Trona was obtained with rail car delivery directly from the mine in Green River,

259

Injection into a fractured geothermal reservoir  

DOE Green Energy (OSTI)

A detailed study is made on the movement of the thermal fronts in the fracture and in the porous medium when 100{sup 0}C water is injected into a 300{sup 0}C geothermal reservoir with equally spaced horizontal fractures. Numerical modeling calculations were made for a number of thermal conductivity values, as well as different values of the ratio of fracture and rock medium permeabilities. One important result is an indication that although initially, the thermal front in the fracture moves very fast relative to the front in the porous medium as commonly expected, its speed rapidly decreases. At some distance from the injection well the thermal fronts in the fracture and the porous medium coincide, and from that point they advance together. The implication of this result on the effects of fractures on reinjection into geothermal reservoirs is discussed.

Bodvarsson, G.S.; Tsang, C.F.

1980-05-01T23:59:59.000Z

260

Transient fault modeling and fault injection simulation  

E-Print Network (OSTI)

An accurate transient fault model is presented in this thesis. A 7-term exponential current upset model is derived from the results of a device-level, 3-dimensional, single-event-upset simulation. A curve-fitting algorithm is used to extract the numerical model from the empirical data. The model is implemented in a HSPICE simulation environment as a current-injection source for fault simulation. The current transient model is used to conduct electrical-level fault injection simulations on a static RAM cell and subcircuits from two commercial microprocessors. The results from the 7-term exponential model are compared with the results from the widely accepted double-exponential transient model. The experimental data indicate that, for a given charge level, the 7-term exponential fault model results in a higher chance of having a latch error. More importantly, different latch-error patterns are captured from the target circuits under the new fault model.

Yuan, Xuejun

1996-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "insar injectivity test" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

PLT neutral injection ignitron accelerating supply  

SciTech Connect

A phase-controlled rectifier was designed for the accelerating supply on the PLT Neutral Beam Injection system at PPPL. The rectifier must furnish 70 amperes at up to 50 KV for 300 milliseconds, with a duty cycle of up to 10 percent. Protection of the injectors requires the supply to withstand repeated crowbarring. The rectifying element selected to satisfy these requirements was a commercially-available ignitron, installed in a supporting frame and using firing circuits and controls designed by PPPL. (auth)

Ashcroft, D.L.; Murray, J.G.; Newman, R.A.; Peterson, F.L.

1975-11-01T23:59:59.000Z

262

Thrombin Injection for Acute Hemorrhage Following Angiography  

SciTech Connect

Femoral arterial puncture is the main access for diagnostic and therapeutic intervention in vascular disease. Significant complications are unusual and include uncontrolled bleeding which usually requires surgery. We report the use of ultrasound-guided thrombin injection that prevented any immediate need for surgery in 2 cases of uncontrolled bleeding following femoral arteriography. Clinical presentations and treatment are reported, together with a review of the literature.

Richards, T., E-mail: tobyrichards@btinternet.com; Mussai, F. J.; Phillips-Hughes, J.; Uberoi, R.; Boardman, P. [John Radcliffe Hospital, Nuffield Department of Surgery and Department of Radiology (United Kingdom)

2007-07-15T23:59:59.000Z

263

Solid hydrogen pellet injection into the ORMAK Tokamak  

DOE Green Energy (OSTI)

Solid hydrogen spheres were injected into the ORMAK tokamak as a test of pellet refueling for tokamak fusion reactors. Pellets 70 ..mu..m and 210 ..mu..m in diameter were injected with speeds of 91 m/sec and 100 m/sec, respectively. Each of the 210-..mu..m pellets added about 1% to the number of particles contained in the plasma. Excited neutrals, ablated from these hydrogen spheres, emitted light which was monitored either by a photomultiplier or by a high speed framing camera. From these light signals it was possible to measure pellet lifetimes, ablation rates, and the spatial distribution of hydrogen atoms in the ablation clouds. The average measured lifetime of the 70-..mu..m pellets was 422 ..mu..sec, and the 210-..mu..m spheres lasted 880 ..mu..sec under bombardment by the plasma. These lifetimes and measured ablation rates are in good agreement with a theoretical model which takes into account shielding of plasma electrons by hydrogen atoms ablated from spherical hydrogen ice.

Foster, C. A.; Colchin, R. J.; Milora, S. L.; Kim, K.; Turnbull, R. J.

1977-06-01T23:59:59.000Z

264

PEP-II injection timing and controls  

SciTech Connect

Hardware has been built and software written and incorporated in the existing SLC accelerator control system to control injection of beam pulses from the accelerator into the PEP-II storage rings currently under construction. Hardware includes a CAMAC module to delay the machine timing fiducial in order that a beam pulse extracted from a damping ring will be injected into a selected group of four 476 MHz buckets in a PEP-II ring. Further timing control is accomplished by shifting the phase of the bunches stored in the damping rings before extraction while leaving the phase of the PEP-II stored beam unchanged. The software which drives timing devices on a pulse-to-pulse basis relies on a dedicated communication link on which one scheduling microprocessor broadcasts a 128-bit message to all distributed control microprocessors at 360 Hz. PEP-II injection will be driven by the scheduling microprocessor according to lists specifying bucket numbers in arbitrary order, and according to scheduling constraints maximizing the useful beam delivered to the SLC collider currently in operation. These lists will be generated by a microprocessor monitoring the current stored per bucket in each of the PEP-II rings.

Bharadwaj, V.; Browne, M.; Crane, M.; Gromme, T.; Himel, T.; Ross, M.; Stanek, M. [Stanford Linear Accelerator Center, Menlo Park, CA (United States); Ronan, M. [Lawrence Berkeley National Lab., CA (United States)

1997-07-01T23:59:59.000Z

265

Economics of dry FGD by sorbent injection  

SciTech Connect

Increasingly stringent pollution control requirements for new power plants have nearly doubled the cost of producing electricity. The capital, operating and maintenance costs of wet flue gas desulfurization (FGD) systems are major, and considerable interest is currently being given to less expensive dry systems. One attractive alternative to wet scrubbing for FGD is to inject a dry, powdered reagent into the duct work between a coal-fired boiler and a FF (baghouse). The reagent (and fly ash) are collected on the fabric surface where the SO/sub 2//reagent contact occurs. The technical aspects of SO/sub 2/ removal using nahcolite and trona as sorbents have been investigated at laboratory-scale, demonstrated at full-scale, and are reported on briefly. These results indicate that injection of sodium based reagents is technically an attractive alternative to the many steps and processes involved in wet scrubbing. This paper summarizes a project to examine the economics of nahcolite/trona and furnace limestone injection FGD and compare them to those of the more advanced spray dryer FGD systems. Uncertainties in material handling, pulverization, and waste disposal were investigated and designs were produced as a basis for cost estimating.

Naulty, D.J.; Hooper, R.; Keeth, R.J.; McDowell, D.A.; Muzio, L.J.; Scheck, R.W.

1983-11-01T23:59:59.000Z

266

Stokes injected Raman capillary waveguide amplifier  

DOE Patents (OSTI)

A device for producing stimulated Raman scattering of CO.sub.2 laser radiation by rotational states in a diatomic molecular gas utilizing a Stokes injection signal. The system utilizes a cryogenically cooled waveguide for extending focal interaction length. The waveguide, in conjunction with the Stokes injection signal, reduces required power density of the CO.sub.2 radiation below the breakdown threshold for the diatomic molecular gas. A Fresnel rhomb is employed to circularly polarize the Stokes injection signal and CO.sub.2 laser radiation in opposite circular directions. The device can be employed either as a regenerative oscillator utilizing optical cavity mirrors or as a single pass amplifier. Additionally, a plurality of Raman gain cells can be staged to increase output power magnitude. Also, in the regenerative oscillator embodiment, the Raman gain cell cavity length and CO.sub.2 cavity length can be matched to provide synchronism between mode locked CO.sub.2 pulses and pulses produced within the Raman gain cell.

Kurnit, Norman A. (Santa Fe, NM)

1980-01-01T23:59:59.000Z

267

Controlling combustion characteristics using a slit nozzle in a direct-injection methanol engine  

SciTech Connect

A new type of fuel injection nozzle, called a `slit nozzle,` has been developed to improve poor ignitability and to stabilize combustion under low load conditions in direct-injection methanol diesel engines manufactured for medium-duty trucks. This nozzle has a single oblong vent like a slit. Engine test results indicate that the slit nozzle can improve combustion and thermal efficiency, especially at low loads and no load. This can be explained by the fact that the slit nozzle forms a more highly concentrated methanol spray around the glow-plug than do multi-hole nozzles. As a result, this nozzle improves flame propagation. 3 refs., 12 figs., 4 tabs.

Kusaka, Jin; Daisho, Yasuhiro; Saito, Takeshi; Kihara, Ryoji

1994-10-01T23:59:59.000Z

268

An Innovative Injection and Mixing System for Diesel Fuel Reforming  

DOE Green Energy (OSTI)

This project focused on fuel stream preparation improvements prior to injection into a solid oxide fuel cell reformer. Each milestone and the results from each milestone are discussed in detail in this report. The first two milestones were the creation of a coking formation test rig and various testing performed on this rig. Initial tests indicated that three anti-carbon coatings showed improvement over an uncoated (bare metal) baseline. However, in follow-up 70 hour tests of the down selected coatings, Scanning Electron Microscope (SEM) analysis revealed that no carbon was generated on the test specimens. These follow-up tests were intended to enable a down selection to a single best anti-carbon coating. Without the formation of carbon it was impossible to draw conclusions as to which anti-carbon coating showed the best performance. The final 70 hour tests did show that AMCX AMC26 demonstrated the lowest discoloration of the metal out of the three down selected anti-carbon coatings. This discoloration did not relate to carbon but could be a useful result when carbon growth rate is not the only concern. Unplanned variations in the series of tests must be considered and may have altered the results. Reliable conclusions could only be drawn from consistent, repeatable testing beyond the allotted time and funding for this project. Milestones 3 and 4 focused on the creation of a preheating pressure atomizer and mixing chamber. A design of experiment test helped identify a configuration of the preheating injector, Build 1, which showed a very uniform fuel spray flow field. This injector was improved upon by the creation of a Build 2 injector. Build 2 of the preheating injector demonstrated promising SMD results with only 22psi fuel pressure and 0.7 in H2O of Air. It was apparent from testing and CFD that this Build 2 has flow field recirculation zones. These recirculation zones may suggest that this Build 2 atomizer and mixer would require steam injection to reduce the auto ignition potential. It is also important to note that to achieve uniform mixing within a short distance, some recirculation is necessary. Milestone 5 generated CFD and FEA results that could be used to optimize the preheating injector. CFD results confirmed the recirculation zones seen in test data and confirmed that the flow field would not change when attached to a reformer. The FEA predicted fuel wetted wall temperatures which led to several suggested improvements that could possibly improve nozzle efficiency. Milestone 6 (originally an optional task) took a different approach than the preheating pressure atomizer. It focused on creation and optimization of a piezoelectric injector which could perform at extremely low fuel pressures. The piezoelectric atomizer showed acceptable SMD results with fuel pressure less than 1.0 psig and air pressure less than 1.0 in H2O. These SMD values were enhanced when a few components were changed, and it is expected would improve further still at elevated air temperatures. It was demonstrated that the piezoelectric injector could accomplish the desired task. The addition of phase tracking and a burst mode to the frequency controller increased the usability of the piezoelectric injector. This injector is ready to move on to the next phase of development. Engine Components has met the required program milestones of this project. Some of the Milestones were adjusted to allow Milestone 6 to be completed in parallel with the other Milestones. Because of this, Task 3.10 and 3.13 were made optional instead of Milestone 6. Engine Components was extremely grateful for the support that was provided by NETL in support of this work.

Spencer Pack

2007-12-31T23:59:59.000Z

269

Geothermal injection technology program. Annual progress report, FY-85  

DOE Green Energy (OSTI)

This report summarizes injection research conducted during FY-1985. The objective was to develop a better understanding of the migration and impact of fluids injected in geothermal reservoirs. Separate abstracts have been prepared for individual project summaries. (ACR)

Not Available

1986-02-01T23:59:59.000Z

270

Near-surface groundwater responses to injection of geothermal wastes  

DOE Green Energy (OSTI)

Experiences with injecting geothermal fluids have identified technical problems associated with geothermal waste disposal. This report assesses the feasibility of injection as an alternative for geothermal wastewater disposal and analyzes hydrologic controls governing the upward migration of injected fluids. Injection experiences at several geothermal developments are presented, including: Raft River, Salton Sea, East Mesa, Otake and Hatchobaru in Japan, and Ahuachapan in El Salvador. Hydrogeologic and design/operational factors affecting the success of an injection program are identified. Hydrogeologic factors include subsidence, near-surface effects of injected fluids, and seismicity. Design/operational factors include hydrodynamic breakthrough, condition of the injection system and reservoir maintenance. Existing and potential effects of production/injection on these factors are assessed.

Arnold, S.C.

1984-06-01T23:59:59.000Z

271

Status of the TOUGH-FLAC simulator and recent applications related to coupled fluid flow and crustal deformations  

E-Print Network (OSTI)

is centered on one CO 2 injection well. Figure 4. InSAR dataground uplift above injection wells KB501 and KB503 (1 to 1.5 km) horizontal injection wells. The three state-of-

Rutqvist, J.

2011-01-01T23:59:59.000Z

272

OPTIMIZATION OF INJECTION INTO VAPOR-DOMINATED GEOTHERMAL  

E-Print Network (OSTI)

. ................................... 19 FIGURE 3.13: ONE-DIMENSIONAL MODEL WITH A PAIR OF INJECTION AND PRODUCTION WELLS. ................... 20 FIGURE 3.14: TWO-DIMENSIONAL MODEL WITH PRODUCTION AND INJECTION WELLS AT THE CENTER.......... 20 and an injection well was placed in the corner diagonally opposite. The maximum production rate of the well

Stanford University

273

Pilot-scale HCl control by dry alkaline injection for emissions from refuse incinerators. Technical report  

Science Conference Proceedings (OSTI)

One method of removing the HCl in an exhaust-gas stream is to directly inject finely divided sorbent particles into the gas stream upstream from particulate collection equipment, allowing enough time for the HCl to react with the sorbent in the duct. The study proposed to provide data on HCl removal from a simulated incinerator exhaust stream as a function of the in-duct reaction/residence time, the reaction temperature, and the sorbent-to-gas ratio. A 500-acfm pilot-scale HCl control system utilizing dry powdered sorbent was tested at the University of Washington. Powdered alkaline reagents including sodium bicarbonate and calcium hydroxide were injected into boiler flue gas spiked with hydrogen chloride gas. The acid gas reacts with the injected sorbent in a 20-inch diameter by 26-foot high vertical, down-flow vessel. HCl removal efficiency was measured as a function of sorbent stoichiometry, gas residence time in reactor, and reaction temperature.

Moore, D.; Pilat, M.

1988-11-08T23:59:59.000Z

274

Analysis of water reinjection at the Niland Geothermal Test Site  

DOE Green Energy (OSTI)

The problems associated with reinjecting spent geothermal brines are currently under investigation. This effort has included field tests of injection water to evaluate treating equipment effectiveness at the Niland Geothermal Test Loop. Membrane filter tests were conducted on fluids from the settling tanks, from the test loop, from the clarifier and at the injection well head (Magmamax No. 3). From this and other information concerning the injection interval, pressure, temperature and well history, an attempt to predict a well half life was made. The results of these calculations were not in agreement with observed well performance. An attempt with some apparent success has been made to understand the possible source of these discrepancies. The cyclic nature of the injection history dictated by need for descaling the test loop, followed by apparent partial recovery of injection acceptance, has led to a theory that is under investigation concerning effect of reheating the injection fluid containing amorphous particulate silica by the reservoir rock and fluid during well shut-in. Preliminary tests indicate some of this finely divided silica may be redisolving with consequent reduction in reservoir damage, and that two widely spaced injection wells in an alternating mode may provide low-cost, long-life injection capacity at Niland and similar geothermal projects.

Jorda, R.M.

1978-05-01T23:59:59.000Z

275

Mitigation of thermoacoustic instability utilizing steady air injection near the flame anchoring zone  

Science Conference Proceedings (OSTI)

The objective of this work is to investigate the effectiveness of steady air injection near the flame anchoring zone in suppressing thermoacoustic instabilities driven by flame-vortex interaction mechanism. We perform a systematic experimental study which involves using two different configurations of air injection in an atmospheric pressure backward-facing step combustor. The first configuration utilizes a row of micro-diameter holes allowing for air injection in the cross-stream direction just upstream of the step. The second configuration utilizes an array of micro-diameter holes located on the face of the step, allowing for air injection in the streamwise direction. The effects of each of these configurations are analyzed to determine which one is more effective in suppressing thermoacoustic instabilities at different operating conditions. The tests are conducted while varying the equivalence ratio and the inlet temperature. The secondary air temperature is always the same as the inlet temperature. We used pure propane or propane/hydrogen mixtures as fuels. Combustion dynamics are explored through simultaneous pressure and heat release-rate measurements, and high-speed video images. When the equivalence ratio of the reactant mixture is high, it causes the flame to flashback towards the inlet channel. When air is injected in the cross-stream direction, the flame anchors slightly upstream of the step, which suppresses the instability. When air is injected in the streamwise direction near the edge of step, thermoacoustic instability could be eliminated at an optimum secondary air flow rate, which depends on the operating conditions. When effective, the streamwise air injection prevents the shedding of an unsteady vortex, thus eliminating the flame-vortex interaction mechanism and resulting in a compact, stable flame to form near the step. (author)

Murat Altay, H.; Hudgins, Duane E.; Speth, Raymond L.; Annaswamy, Anuradha M.; Ghoniem, Ahmed F. [Massachusetts Institute of Technology, Department of Mechanical Engineering, Cambridge, MA 02139 (United States)

2010-04-15T23:59:59.000Z

276

Ball Rust Test(ASTM D 6557) FIELD SERVICE SIMULATED  

E-Print Network (OSTI)

-controlled shaker table. A syringe pump is used to inject acid into the test oil. In addition, a compressed air the Sequence IID (ASTM D 5844) gaso- line engine test, and evaluates the ability of an oil to prevent with regard to rusting. TEST PARAMETERS Tests are run for 18 hours with the test oil environment controlled

Chapman, Clark R.

277

Ammonia Monitor Lab Test Verification  

Science Conference Proceedings (OSTI)

This report provides results from performance tests of a Laser Tech Group (LTG) Lightwise tunable diode laser (TDL) monitor at the University of CaliforniaRiverside's laboratory test facility. More stringent nitrogen oxide(s) (NOx)-control mandates for coal-fired boilers have engendered broad-based deployment of post-combustion NOx control systems. It is possible to increase NOx reductions early in the catalyst life cycle through increased reagent injection, with a concomitant increase in ammonia (NH3) ...

2009-07-13T23:59:59.000Z

278

Test Cell Location  

NLE Websites -- All DOE Office Websites (Extended Search)

Chrysler 300 Chrysler 300 Test Cell Location 2WD Vehicle Setup Information Downloadable Dynamometer Database (D 3 )- Test Summary Sheet Vehicle Architecture Conventional Vehicle Dynamometer Input Document Date 8/7/2013 Advanced Powertrain Research Facility Test weight [lb] Target A [lb] 4250 38.61 Target B [lb/mph] Target C [lb/mph^2] 0.8894 0.01105 3.6L VVT Port-injected V-6 8 speed Transmission Revision Number 3 Notes: Test Fuel Information 3.6L VVT Port-injected V-6 8 speed Transmission Fuel type Tier II EEE HF437 3.6L VVT Port-injected V-6 8 speed Transmission Fuel density [g/ml] Fuel Net HV [BTU/lbm] 0.743 18490 T e s t I D [ # ] C y c l e C o l d s t a r t ( C S t ) H o t s t a r t [ H S t ] D a t e T e s t C e l l T e m p [ C ] T e s t C e l l R H [ % ] T e s t C e l l B a r o [ i n / H g ] V e h i c l e c o o l i n g f a n s p e e d : S p e e d M a t c h [ S M ] o r c o n s t a n t s p e e d [ C S ] S

279

Projective Space Codes for the Injection Metric  

E-Print Network (OSTI)

In the context of error control in random linear network coding, it is useful to construct codes that comprise well-separated collections of subspaces of a vector space over a finite field. In this paper, the metric used is the so-called "injection distance", introduced by Silva and Kschischang. A Gilbert-Varshamov bound for such codes is derived. Using the code-construction framework of Etzion and Silberstein, new non-constant-dimension codes are constructed; these codes contain more codewords than comparable codes designed for the subspace metric.

Khaleghi, Azadeh

2009-01-01T23:59:59.000Z

280

Nox reduction system utilizing pulsed hydrocarbon injection  

DOE Patents (OSTI)

Hydrocarbon co-reductants, such as diesel fuel, are added by pulsed injection to internal combustion engine exhaust to reduce exhaust NO.sub.x to N.sub.2 in the presence of a catalyst. Exhaust NO.sub.x reduction of at least 50% in the emissions is achieved with the addition of less than 5% fuel as a source of the hydrocarbon co-reductants. By means of pulsing the hydrocarbon flow, the amount of pulsed hydrocarbon vapor (itself a pollutant) can be minimized relative to the amount of NO.sub.x species removed.

Brusasco, Raymond M. (Livermore, CA); Penetrante, Bernardino M. (San Ramon, CA); Vogtlin, George E. (Fremont, CA); Merritt, Bernard T. (Livermore, CA)

2001-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "insar injectivity test" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Numerical simulation of water injection into vapor-dominated reservoirs  

DOE Green Energy (OSTI)

Water injection into vapor-dominated reservoirs is a means of condensate disposal, as well as a reservoir management tool for enhancing energy recovery and reservoir life. We review different approaches to modeling the complex fluid and heat flow processes during injection into vapor-dominated systems. Vapor pressure lowering, grid orientation effects, and physical dispersion of injection plumes from reservoir heterogeneity are important considerations for a realistic modeling of injection effects. An example of detailed three-dimensional modeling of injection experiments at The Geysers is given.

Pruess, K.

1995-01-01T23:59:59.000Z

282

UP-GRADED RHIC INJECTION SYSTEM.  

Science Conference Proceedings (OSTI)

The design of the RHIC injection systems anticipated the possibility of filling and operating the rings with a 120 bunch pattern, corresponding to 110 bunches after allowing for the abort gap. Beam measurements during the 2002 run confirmed the possibility, although at the expense of severe transverse emittance growth and thus not on an operational basis. An improvement program was initiated with the goal of reducing the kicker rise time from 110 to {approx}95 ns and of minimizing pulse timing jitter and drift. The major components of the injection system are 4 kicker magnets and Blmlein pulsers using thyratron switches. The kicker terminating resistor and operating voltage was increased to reduce the rise time. Timing has been stabilized by using commercial trigger units and extremely stable dc supplies for the thyratron reservoir. A fiber optical connection between control room and the thyratron trigger unit has been provided, thereby allowing the operator to adjust timing individually for each kicker unit. The changes were successfully implemented for use in the RHIC operation.

HAHN,H.FISCHER,W.SEMERTZIDIS,Y.K.WARBURTON,D.S.

2003-05-12T23:59:59.000Z

283

Supersonic Jet Excitation using Flapping Injection  

E-Print Network (OSTI)

Supersonic jet noise reduction is important for high speed military aircraft. Lower acoustic levels would reduce structural fatigue leading to longer lifetime of the jet aircraft. It is not solely structural aspects which are of importance, health issues of the pilot and the airfield per- sonnel are also very important, as high acoustic levels may result in severe hearing damage. It remains a major challenge to reduce the overall noise levels of the aircraft, where the supersonic exhaust is the main noise source for near ground operation. Fluidic injection into the supersonic jet at the nozzle exhaust has been shown as a promising method for noise reduction. It has been shown to speed up the mix- ing process of the main jet, hence reducing the kinetic energy level of the jet and the power of the total acoustic radiation. Furthermore, the interaction mechanism between the fluidic injection and the shock structure in the jet exhaust plays a crucial role in the total noise radia- tion. In this study, LES is used...

Hafsteinsson, Haukur; Andersson, Niklas; Cuppoletti, Daniel; Gutmark, Ephraim; Prisell, Erik

2013-01-01T23:59:59.000Z

284

Ejector device for direct injection fuel jet  

SciTech Connect

Disclosed is a device for increasing entrainment and mixing in an air/fuel zone of a direct fuel injection system. The device comprises an ejector nozzle in the form of an inverted funnel whose central axis is aligned along the central axis of a fuel injector jet and whose narrow end is placed just above the jet outlet. It is found that effective ejector performance is achieved when the ejector geometry is adjusted such that it comprises a funnel whose interior surface diverges about 7.degree. to about 9.degree. away from the funnel central axis, wherein the funnel inlet diameter is about 2 to about 3 times the diameter of the injected fuel plume as the fuel plume reaches the ejector inlet, and wherein the funnel length equal to about 1 to about 4 times the ejector inlet diameter. Moreover, the ejector is most effectively disposed at a separation distance away from the fuel jet equal to about 1 to about 2 time the ejector inlet diameter.

Upatnieks, Ansis (Livermore, CA)

2006-05-30T23:59:59.000Z

285

The Impact of Injection on Seismicity at The Geyses, California Geothermal Field  

E-Print Network (OSTI)

of thermoelastic stress on injection well fracturing. SPE38N) LBNL NCSN POWER PLANTS INJECTION WELLS EVENTS LBNLNCSN POWER PLANTS INJECTION WELLS EVENTS Aidlin 11 - LBNL

Majer, Ernest L.; Peterson, John E.

2008-01-01T23:59:59.000Z

286

Effects of carbon dioxide injection on the displacement of methane and carbonate dissolution in sandstone cores  

E-Print Network (OSTI)

Previous coreflood experiments show that CO2 sequestration in carbonate rocks is a win-win technology. Injecting CO2 into a depleted gas reservoir for storage also produces hitherto unrecoverable gas. This in turn helps to defray the cost of CO2 sequestration. This thesis reports the results from experiments conducted on a Berea sandstone core. The experiments include displacement experiments and unconfined compressive strength tests. The displacement experiments were conducted at cell pressures of 1500 psig and temperature of 60oC using a 1 foot long and 1 inch diameter Berea sandstone core. Pure CO2 and treated flue gas (99.433 % mole CO2) were injected into the Berea sandstone core initially saturated with methane at a pressure of 1500 psig and 800 psig respectively. Results from these experiments show that the dispersion coefficient for both pure CO2 and treated flue gas are relatively small ranging from 0.18-0.225 cm2/min and 0.28-0.30 cm2/min respectively. The recovery factor of methane at break-through is relatively high ranging from 71%-80% of original gas in place for pure CO2 and 90% to 92% OGIP for treated flue gas, the difference resulting from different cell pressures used. Therefore it would appear that, in practice injection of treated flue gas is a cheaper option compared to pure CO2 injection. For the unconfined compressive strength tests, corefloods were first conducted at high flowrates ranging from 5 ml/min to 20 ml/ min, pressures of 1700-1900 Psig and a temperature of 65oC. These conditions simulate injecting CO2 originating from an electric power generation plant into a depleted gas reservoir and model the near well bore situation. Results from these experiments show a 1% increase in porosity and changes in injectivity due to permeability impairment. The cores are then subjected to an unconfined compressive strength test. Results from these tests do not show any form of weakening of the rock due to CO2 injection.

Maduakor, Ekene Obioma

2006-08-01T23:59:59.000Z

287

Chemical tracer test at the Dixie Valley geothermal field, Nevada. Geothermal Reservoir Technology research program  

DOE Green Energy (OSTI)

In the injection test described, chemical tracers established the fluid flow between one injection well and one production well. Measured tracer concentrations, calculated flow rates, sampling schedules, and the daily events of the tracer test are documented. This experiment was designed to test the application of organic tracers, to further refine the predictive capability of the reservoir model, and to improve the effectiveness of Oxbow`s injection strategy.

Adams, M.C.; Moore, J.N. [Utah Univ. Research Inst., Salt Lake City, UT (United States); Benoit, W.R. [Oxbow Geothermal Corp., Reno, NV (United States); Doughty, C.; Bodvarsson, G.S. [Lawrence Berkeley Lab., CA (United States)

1993-10-01T23:59:59.000Z

288

Coal combustion under conditions of blast furnace injection. Final technical report, September 1, 1992--August 31, 1993  

Science Conference Proceedings (OSTI)

A potentially new use for Illinois coal is as a fuel injected into a blast furnace to produce molten iron as the first step in steel production. Because of its increasing cost and decreasing availability, metallurgical coke is now being replaced by coal injected at the tuyere area of the furnace where the blast air enters. The purpose of this study is to evaluate the combustion of coal during the blast furnace injection process and to delineate the optimum properties of the feed coal. This investigation is significant to the use of Illinois coal in that the limited research to date suggests that coals of low fluidity and moderate to high sulfur and chlorine contents are suitable feedstocks for blast furnace injection. During the first phase of this project a number of the objectives were realized, specifically: (1) a blast furnace sampling system was developed and used successfully to collect samples inside an active furnace; (2) two sets of blast furnace samples were collected and petrographic analysis showed that char derived from injected coal is entering the reduction zone of the furnace; (3) a coal/char sampling probe was designed and fabricated; (4) the completion of a program of reactivity experiments on the injected coal char, blast furnace coke and Herrin No. 6 char. The results of the reactivity experiments indicate that Herrin No. 6 coal is similar or even superior to coals now being used in blast furnace injection and that additional testing is warranted.

Crelling, J.C. [Southern Illinois Univ., Carbondale, IL (United States). Dept. of Geology; Case, E.R. [Armco, Inc., Middletown, OH (United States). Research and Technology Div.

1993-12-31T23:59:59.000Z

289

Performance and Economics of Catalytic Glow Plugs and Shields in Direct Injection Natural Gas Engines for the Next Generation Natural Gas Vehicle Program: Final Report  

DOE Green Energy (OSTI)

Subcontractor report details work done by TIAX and Westport to test and perform cost analysis for catalytic glow plugs and shields for direct-injection natural gas engines for the Next Generation Natural Gas Vehicle Program.

Mello, J. P.; Bezaire, D.; Sriramulu, S.; Weber, R.

2003-08-01T23:59:59.000Z

290

Characterization of injection wells in a fractured reservoir using PTS logs, Steamboat Hills Geothermal Field, Nevada, USA  

DOE Green Energy (OSTI)

The Steamboat Hills Geothermal Field in northwestern Nevada, about 15 km south of Reno, is a shallow (150m to 825m) moderate temperature (155 C to 168 C) liquid-dominated geothermal reservoir situated in highly-fractured granodiorite. Three injection wells were drilled and completed in granodiorite to dispose of spent geothermal fluids from the Steamboat II and III power plants (a 30 MW air-cooled binary-type facility). Injection wells were targeted to depths below 300m to inject spent fluids below producing fractures. First, quasi-static downhole pressure-temperature-spinner (PTS) logs were obtained. Then, the three wells were injection-tested using fluids between 80 C and 106 C at rates from 70 kg/s to 200 kg/s. PTS logs were run both up and down the wells during these injection tests. These PTS surveys have delineated the subsurface fracture zones which will accept fluid. The relative injectivity of the wells was also established. Shut-in interzonal flow within the wells was identified and characterized.

Goranson, Colin; Combs, Jim

1995-01-26T23:59:59.000Z

291

Site Characterization Plan: Uranium Stabilization through Polyphosphate Injection  

Science Conference Proceedings (OSTI)

An initial feasibility study of options to treat the uranium plume at the 300-FF-5 Operable Unit considered hydraulic containment, slurry wall containment, and groundwater extraction as potential remedial action technologies. None were selected for interim action, and reduction of contamination levels by natural processes was considered a viable alternative while source removal actions continued. Subsequent planning for a Phase III feasibility study focused on methods that would reduce the concentration of uranium in the aquifer, including multiple methods to immobilize uranium using chemical-based technologies. Based on an initial technology screening, the polyphosphate technology was identified as the best candidate to treat the for further evaluation and selected for treatability testing. The overall objective of the polyphosphate treatability test is to evaluate the efficacy of using polyphosphate injections to treat uranium contaminated groundwater in situ. The objective of the work elements included in this site characterization plan is to collect site-specific characterization data that will be needed to design and implement a field-scale demonstration of the technology.

Vermeul, Vince R.; Fruchter, Jonathan S.; Wellman, Dawn M.; Williams, Bruce A.; Williams, Mark D.

2006-12-01T23:59:59.000Z

292

GAS INJECTION/WELL STIMULATION PROJECT  

SciTech Connect

Driver Production proposes to conduct a gas repressurization/well stimulation project on a six well, 80-acre portion of the Dutcher Sand of the East Edna Field, Okmulgee County, Oklahoma. The site has been location of previous successful flue gas injection demonstration but due to changing economic and sales conditions, finds new opportunities to use associated natural gas that is currently being vented to the atmosphere to repressurize the reservoir to produce additional oil. The established infrastructure and known geological conditions should allow quick startup and much lower operating costs than flue gas. Lessons learned from the previous project, the lessons learned form cyclical oil prices and from other operators in the area will be applied. Technology transfer of the lessons learned from both projects could be applied by other small independent operators.

John K. Godwin

2005-12-01T23:59:59.000Z

293

Boise geothermal injection well: Final environmental assessment  

DOE Green Energy (OSTI)

The City of Boise, Idaho, an Idaho Municipal Corporation, is proposing to construct a well with which to inject spent geothermal water from its hot water heating system back into the geothermal aquifer. Because of a cooperative agreement between the City and the US Department of Energy to design and construct the proposed well, compliance to the National Environmental Policy Act (NEPA) is required. Therefore, this Environmental Assessment (EA) represents the analysis of the proposed project required under NEPA. The intent of this EA is to: (1) briefly describe historical uses of the Boise Geothermal Aquifer; (2) discuss the underlying reason for the proposed action; (3) describe alternatives considered, including the No Action Alternative and the Preferred Alternative; and (4) present potential environmental impacts of the proposed action and the analysis of those impacts as they apply to the respective alternatives.

NONE

1997-12-31T23:59:59.000Z

294

New type gas-injection plant readied  

SciTech Connect

A unique gas-injection plant is about to go on stream in Venezuela's Lake Maracaibo. The $10-million installation, designed for unattended operation, is a joint venture of Phillips Petroleum Co., as operator for itself, and Cia. Shell de Venezuela. The plant, housed on a 120 by 130-ft platform, will be the first in the world to use gas turbines to drive reciprocating compressors. The 130 MMscfd facility will use 2 General Electric 15,000-hp gas turbines with gear reducers to drive a pair of 4-stage Cooper- Bessemer LM-8 compressors. No previous attempt has ever been made to drive this type of unit by gas turbines. Phillips says the gas turbines were selected because of inherent flexibility reliability as prime movers, and lack of vibration--an important advantage in offshore gas plants.

Franco, A.

1967-07-17T23:59:59.000Z

295

Current drive, anticurrent drive, and balanced injection  

SciTech Connect

In lower hybrid (LH) discharges, the number of suprathermal electrons is limited by the upper bound on the current density from the q = 1 condition, which is caused by the onset of the m = 1 MHD instability. The stored energy of suprathermal electrons, measured in terms of a poloidal beta, scales with plasma current as I/sub p//sup -1/. Potentially, these bounds represent very restrictive conditions for heating in larger machines. Consequently, it seems necessary to perform experiments where the electrons are driven in both directions, parallel and antiparallel to the magnetic field, i.e., bidirectional scenarios like anticurrent drive or balanced injection. Data from PLT relevant to these ideas are discussed. 6 refs., 4 figs.

von Goeler, S.; Stevens, J.; Beiersdorfer, P.; Bell, R.; Bernabei, S.; Bitter, M.; Cavallo, A.; Chu, T.K.; Fishman, H.; Hill, K.

1987-08-01T23:59:59.000Z

296

Waste heat steams ahead with injection technology  

Science Conference Proceedings (OSTI)

Owners of Commercial-Industrial-Institutional buildings whose thermal usage is too variable to implement cogeneration are looking to a gasturbine steam-injection technology, called the Cheng Cycle, to reduce their energy costs. The Cheng Cycle uses industrial components-a gas-turbine generating set, a waste-heat recovery steam generator and system controls-in a thermodynamically optimized mode. In the process, steam produced from waste heat can be used for space or process heating or to increase the electrical output of a gas turbine. The process was patented in 1974 by Dr. Dah Yu Cheng, of the University of Santa Clara, Santa Clara, Calif. When a plant's thermal needs fall because of production or temperature changes, unused steam is directed back to the turbine to increase electrical output. As thermal requirements rise, the process is reversed and needed steam is channeled to plant uses.

Shepherd, S.; Koloseus, C.

1985-03-01T23:59:59.000Z

297

D/sub 2/ - pellet injection system  

Science Conference Proceedings (OSTI)

For density build-up of a target plasma for neutral injection in the stellarator ''Wendelstein W VIIA''and for refuelling of the divertor tokamak ASSDEX, pellet light gas guns have been developed. In a continuous flow cryostat cooled by liquid helium with a comsumption of 2 - 3 liter liquid helium per hour deuterium was condensed and solidified. To prevent the propeller gas entering the torus was used. In one system a 3.6 mm guiding tube following the barrel was applied successfully. By optical diagnostics pellet velocity, pellet size and pellet trajectory is measured. For a pellet centrifuge system investigations of carbon fiber rotors were made up to surface velocities of 1500 m/s.

Buechl, K.; Andelfinger, C.; Kollotzek, H.; Lang, R.; Ulrich, M.

1981-01-01T23:59:59.000Z

298

Tracer Testing At Raft River Geothermal Area (1983) | Open Energy  

Open Energy Info (EERE)

3) 3) Exploration Activity Details Location Raft River Geothermal Area Exploration Technique Tracer Testing Activity Date 1983 Usefulness not indicated DOE-funding Unknown Exploration Basis To develop chemical tracing procedures for geothermal areas. Notes Two field experiments were conducted to develop chemical tracer procedures for use with injection-backflow testing, one on the fracture-permeability Raft River reservoir and the other on the matrix-permeability East Mesa reservoir. Results from tests conducted with incremental increases in the injection volume at both East Mesa and Raft River suggests that, for both reservoirs, permeability remained uniform with increasing distance from the well bore. Increased mixing during quiescent periods, between injection and

299

Arkansas Underground Injection Control Code (Arkansas) | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Arkansas Underground Injection Control Code (Arkansas) Arkansas Underground Injection Control Code (Arkansas) Arkansas Underground Injection Control Code (Arkansas) < Back Eligibility Commercial Construction Industrial Utility Program Info State Arkansas Program Type Environmental Regulations Siting and Permitting Provider Department of Environmental Quality The Arkansas Underground Injection Control Code (UIC code) is adopted pursuant to the provisions of the Arkansas Water and Air Pollution Control Act (Arkansas Code Annotated 8-5-11). It is the purpose of this UIC Code to adopt underground injection control (UIC) regulations necessary to qualify the State of Arkansas to retain authorization for its Underground Injection Control Program pursuant to the Safe Drinking Water Act of 1974, as amended; 42 USC 300f et seq. In order

300

T-731:Symantec IM Manager Code Injection Vulnerability | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

T-731:Symantec IM Manager Code Injection Vulnerability T-731:Symantec IM Manager Code Injection Vulnerability T-731:Symantec IM Manager Code Injection Vulnerability September 30, 2011 - 8:30am Addthis PROBLEM: Symantec IM Manager Code Injection Vulnerability. PLATFORM: IM Manager versions prior to 8.4.18 are affected. ABSTRACT: Symantec IM Manager is prone to a vulnerability that will let attackers run arbitrary code. referecnce LINKS: Symantec Security Advisory SYM11-012 Symantec Security Updates Bugtraq ID: 49742 IMPACT ASSESSMENT: High Discussion: Symantec was notified of Cross-Site Scripting and Code injection/execution issues present in the Symantec IM Manager management console. The management console fails to properly filter/validate external inputs. Successful exploitation of SQL Injection or Remote Code execution might

Note: This page contains sample records for the topic "insar injectivity test" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

INJECTION SYSTEM DESIGN FOR THE BSNS/RCS.  

SciTech Connect

The BSNS injection system is designed to take one uninterrupted long drift in one of the four dispersion-free straight sections to host all the injection devices. Painting bumper magnets are used for both horizontal and vertical phase space painting. Closed-orbit bumper magnets are used for facilitating the installation of the injection septa and decreasing proton traversal in the stripping foil. Even with large beam emittance of about 300 {pi}mm.mrad used, BSNS/RCS still approaches the space charge limit during the injection/trapping phase for the accumulated particles of 1.9*10{sup 13} and at the low injection energy of 80 MeV. Uniform-like beam distribution by well-designed painting scheme is then obtained to decrease the tune shift/spread. ORBIT code is used for the 3D simulations. Upgrading to higher injection energy has also been considered.

WEI, J.; TANG, J.Y.; CHEN, Y.; CHI, Y.L.; JIANG, Y.L.; KANG, W.; PANG, J.B.; QIN, Q.; QIU, J.; SHEN, L.; WANG, W.

2006-06-23T23:59:59.000Z

302

The Impact of Injection on Seismicity at The Geyses, California Geothermal Field  

E-Print Network (OSTI)

have been injecting steam condensate, local rain and streamhave been injecting steam condensate, local rain and stream

Majer, Ernest L.; Peterson, John E.

2008-01-01T23:59:59.000Z

303

INTENSITY OF BETATRON RADIATION AS FUNCTION OF INJECTION VOLTAGE  

SciTech Connect

The intensity of betatron radiation emission as a function of injection voltage was studied using a 25-Mev betatron with a 350-kw external electron injector. The injection voltage was measured every 20 to 30 kw from 50 to 250 kw. The results showed that up to 250 kw, emission intensity increases according to theory. It is suggested that an increase in injection intensity up to 1000 kw and over should result in a considerable rise in emission intensity. (R.V.J.)

Moskalev, V.A.; Okulov, B.V.

1962-09-01T23:59:59.000Z

304

Numerical modeling of injection experiments at The Geysers  

DOE Green Energy (OSTI)

Data from injection experiments in the southeast Geysers are presented that show strong interference (both negative and positive) with a neighboring production well. Conceptual and numerical models are developed that explain the negative interference (decline of production rate) in terms of heat transfer limitations and water-vapor relative permeability effects. Recovery and over-recovery following injection shut-in are attributed to boiling of injected fluid, with heat of vaporization provided by the reservoir rocks.

Pruess, K. [Lawrence Berkeley Lab., CA (United States); Enedy, S. [Northern California Power Agency, Middletown, CA (United States)

1993-01-01T23:59:59.000Z

305

Method for controlling corrosion in thermal vapor injection gases  

DOE Patents (OSTI)

An improvement in the method for producing high pressure thermal vapor streams from combustion gases for injection into subterranean oil producing formations to stimulate the production of viscous minerals is described. The improvement involves controlling corrosion in such thermal vapor gases by injecting water near the flame in the combustion zone and injecting ammonia into a vapor producing vessel to contact the combustion gases exiting the combustion chamber.

Sperry, John S. (Houston, TX); Krajicek, Richard W. (Houston, TX)

1981-01-01T23:59:59.000Z

306

Experimental investigation of caustic steam injection for heavy oils  

E-Print Network (OSTI)

An experimental study has been conducted to compare the effect of steam injection and caustic steam injection in improving the recovery of San Ardo and Duri heavy oils. A 67 cm long x 7.4 cm O.D (outer diameter), steel injection cell is used in the study. Six thermocouples are placed at specific distances in the injection cell to record temperature profiles and thus the steam front velocity. The injection cell is filled with a mixture of oil, water and sand. Steam is injected at superheated conditions of 238oC with the cell outlet pressure set at 200 psig, the cell pressure similar to that found in San Ardo field. The pressure in the separators is kept at 50 psig. The separator liquid is sampled at regular intervals. The liquid is centrifuged to determine the oil and water volumes, and oil viscosity, density and recovery. Acid number measurements are made by the titration method using a pH meter and measuring the EMF values. The interfacial tensions of the oil for different concentrations of NaOH are also measured using a tensionometer. Experimental results show that for Duri oil, the addition of caustic results in an increase in recovery of oil from 52% (steam injection) to 59 % (caustic steam injection). However, caustic has little effect on San Ardo oil where oil recovery is 75% (steam injection) and 76 % (caustic steam injection). Oil production acceleration is seen with steam-caustic injection. With steam caustic injection there is also a decrease in the produced oil viscosity and density for both oils. Sodium hydroxide concentration of 1 wt % is observed to give the lowest oil-caustic interfacial tension. The acid numbers for San Ardo and Duri oil are measured as 6.2 and 3.57 respectively.

Madhavan, Rajiv

2009-05-01T23:59:59.000Z

307

FY2002 Progress Report for Fuels for Advanced Compression Ignition Direct Injection (CIDI) Engines  

NLE Websites -- All DOE Office Websites (Extended Search)

Fuels for Advanced Compression Fuels for Advanced Compression Ignition Direct Injection (CIDI) Engines Energy Efficiency and Renewable Energy Office of FreedomCAR and Vehicle Technologies Approved by Stephen Goguen November 2002 Fuels for Advanced CIDI Engines FY 2002 Progress Report iii CONTENTS CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii INDEX OF PRIMARY CONTACTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v I. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 II. FUEL/LUBRICANT EFFECTS TESTING ON ENGINE PERFORMANCE . . . . . . . . . 13 A. Oil Consumption Contribution to CIDI PM Emissions during Transient Operation . . . . . . . . . . . . . . . . . . . .13

308

Early Hydrogen Water Chemistry Injection in Boiling Water Reactors: Impact on Fuel Performance and Reliability  

Science Conference Proceedings (OSTI)

Early injection of hydrogen during plant startup has been proposed to further mitigate intergranular stress corrosion cracking (IGSCC) in boiling water reactors (BWRs). To assess the effectiveness of early hydrogen water chemistry (EHWC), laboratory tests were performed under simulated BWR startup conditions at 200-400F in the absence of radiation with pre-oxidized stainless steel specimens treated with noble metals to simulate plant surfaces. The ...

2012-12-13T23:59:59.000Z

309

Hydrologic Tests at Characterization Well R-14  

Science Conference Proceedings (OSTI)

Well R-14 is located in Ten Site Canyon and was completed at a depth of 1316 ft below ground surface (bgs) in August 2002 within unassigned pumiceous deposits located below the Puye Formation (fanglomerate). The well was constructed with two screens positioned below the regional water table. Individual static depths measured for each isolated screen after the Westbay{trademark} transducer monitoring system was installed in mid-December 2002 were nearly identical at 1177 ft bgs, suggesting only horizontal subsurface flow at this time, location, and depth. Screen 1 straddles the geologic contact between the Puye fanglomerate and unassigned pumiceous deposits. Screen 2 is located about 50 ft deeper than screen 1 and is only within the unassigned pumiceous deposits. Constant-rate, straddle-packer, injection tests were conducted at screen 2, including two short tests and one long test. The short tests were 1 minute each but at different injection rates. These short tests were used to select an appropriate injection rate for the long test. We analyzed both injection and recovery data from the long test using the Theis, Theis recovery, Theis residual-recovery, and specific capacity techniques. The Theis injection, Theis recovery, and specific capacity methods correct for partial screen penetration; however, the Theis residual-recovery method does not. The long test at screen 2 involved injection at a rate of 10.1 gallons per minute (gpm) for 68 minutes and recovery for the next 85 minutes. The Theis analysis for screen 2 gave the best fit to residual recovery data. These results suggest that the 158-ft thick deposits opposite screen 2 have a transmissivity (T) equal to or greater than 143 ft{sup 2}/day, and correspond to a horizontal hydraulic conductivity (K) of at least 0.9 ft/day. The specific capacity method yielded a T value equal to or greater than 177 ft{sup 2}/day, and a horizontal K of at least 1.1 ft/day. Results from the injection and recovery phases of the test at screen 2 were similar to those from the residual-recovery portion of the test, but were lower by a factor of about two. The response to injection was typical for a partially penetrating well screen in a very thick aquifer.

S. McLin; W. Stone

2004-08-01T23:59:59.000Z

310

Coal combustion under conditions of blast furnace injection. Technical report, March 1, 1994--May 31, 1994  

Science Conference Proceedings (OSTI)

A potentially new use for Illinois coal is its use as a fuel injected into a blast furnace to produce molten iron as the first step in steel production. Because of its increasing cost and decreasing availability, metallurgical coke is now being replaced by coal injected at the tuyere area of the furnace where the blast air enters. The purpose of this study is to evaluate the combustion of coal during the blast furnace injection process and to delineate the optimum properties of the feed coal. This investigation is significant to the use of Illinois coal in that the limited research to date suggests that coals of low fluidity and moderate to high sulfur and chlorine contents are suitable feedstocks for blast furnace injection. This proposal is a follow-up to one funded for the 1992-93 period. It is intended to complete the study already underway with the Armco Inc. Steel Company and to initiate a new cooperative study along somewhat similar lines with the Inland Steel Company. The results of this study will lead to the development of a testing and evaluation protocol that will give a unique and much needed understanding of the behavior of coal in the injection process and prove the potential of Illinois coals for such use. During this quarter samples of two feed coals and the IBCSP 112 (Herrin No. 6) were prepared for reactivity testing and compared to blast furnace coke, and char fines taken from an active blast furnace. As the initial part of a broad reactivity analysis program, these same samples were also analyzed on a thermogravimetric analyzer (TGA) to determine their combustion and reactivity properties.

Crelling, J.C. [Southern Illinois Univ., Carbondale, IL (United States)

1994-09-01T23:59:59.000Z

311

Influence of water injection on performance and emissions of a direct-injection hydrogen research engine.  

DOE Green Energy (OSTI)

The application of hydrogen (H{sub 2}) as an internal combustion (IC) engine fuel has been under investigation for several decades. The favorable physical properties of hydrogen make it an excellent alternative fuel for IC engines and hence it is widely regarded as the energy carrier of the future. Direct injection of hydrogen allows optimizing this potential as it provides multiple degrees of freedom to influence the in-cylinder combustion processes and consequently engine efficiency and exhaust emissions.

Nande, A. M.; Wallner, T.; Naber, J. (Energy Systems); (MIchigan Technological Univ.)

2008-10-06T23:59:59.000Z

312

NETL: News Release - DOE Technology Monitors CO2 Injection in...  

NLE Websites -- All DOE Office Websites (Extended Search)

3, 2008 DOE Technology Monitors CO2 Injection in Australian Gas Field CSLF Project Demonstrates Unique Carbon Sequestration Technologies WASHINGTON, D.C. - Australia has launched...

313

Injection Phenomena in the PS Converter - The Teachings of J ...  

Science Conference Proceedings (OSTI)

blockage and punching); the concept of high pressure or sonic injection including a review of the ... to the representatives of the technology suppliers as well as.

314

Injection of Alternative Carbon Containing Materials in the BF  

Science Conference Proceedings (OSTI)

By injection of the materials preparation methods in terms e.g. drying and/or ... Efficiency in recovery of valuable compounds as well as the behaviour of...

315

Application of Metal Injection Molding to Soft Magnetic Materials  

Science Conference Proceedings (OSTI)

Advances in Current Activated Tip-Based Sintering (CATS) Advances in Synthesis and Densification of Heterogeneous Materials Application of Metal Injection...

316

Capsule injection system for a hydraulic capsule pipelining system  

DOE Patents (OSTI)

An injection system for injecting capsules into a hydraulic capsule pipelining system, the pipelining system comprising a pipeline adapted for flow of a carrier liquid therethrough, and capsules adapted to be transported through the pipeline by the carrier liquid flowing through the pipeline. The injection system comprises a reservoir of carrier liquid, the pipeline extending within the reservoir and extending downstream out of the reservoir, and a magazine in the reservoir for holding capsules in a series, one above another, for injection into the pipeline in the reservoir. The magazine has a lower end in communication with the pipeline in the reservoir for delivery of capsules from the magazine into the pipeline.

Liu, Henry (Columbia, MO)

1982-01-01T23:59:59.000Z

317

Study Reveals Fuel Injection Timing Impact on Particle Number...  

NLE Websites -- All DOE Office Websites (Extended Search)

In an ongoing quest to meet ever-more-rigorous fuel economy and emissions requirements, vehicle manufacturers are increasingly turning to gasoline direct injection (GDI) coupled...

318

Dry sorbent injection may serve as a key pollution control ...  

U.S. Energy Information Administration (EIA)

Dry sorbent injection (DSI) is a pollution control technology that may play a role in the United States' electric power sector's compliance with the Mercury and Air ...

319

Improvement of Mechanical Properties of Injection Molded Wood  

Science Conference Proceedings (OSTI)

... by one double-gate injection mould integrated an ultrasonic generator unit. ... Polymer Based Composite and Hybrid Materials for Wind Power Generation.

320

Duct injection technology prototype development: Evaluation of engineering data  

SciTech Connect

The objective of the Duct Injection Technology Prototype Development Project is to develop a sound design basis for applying duct injection technology as a post-combustion SO{sub 2}emissions control method to existing coal-fired power plants. The necessary engineering design and scale-up criteria will be developed for the commercialization of duct injection technology for the control of SO{sub 2} emissions from coal-fired boilers in the utility industry. The primary focus of the analyses summarized in this Topical Report is the review of the known technical and economic information associated with duct injection technology. (VC)

Not Available

1990-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "insar injectivity test" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Alaska Natural Gas Injections into Underground Storage (Million...  

U.S. Energy Information Administration (EIA) Indexed Site

of Natural Gas into Underground Storage - All Operators Alaska Underground Natural Gas Storage - All Operators Injections of Natural Gas into Storage (Annual Supply &...

322

Rhode Island Natural Gas Underground Storage Injections All Operators...  

U.S. Energy Information Administration (EIA) Indexed Site

of Natural Gas into Underground Storage - All Operators Rhode Island Underground Natural Gas Storage - All Operators Injections of Natural Gas into Storage (Annual Supply &...

323

Completion report: Raft River Geothermal Injection Well Six (RRGI-6)  

DOE Green Energy (OSTI)

Raft River Geothermal Injection Well Six (RRGI-6) is an intermediate-depth injection well designed to accept injection water in the 600 to 1000 m (2000 to 3500 ft) depth range. It has one barefoot leg, and it was drilled so that additional legs can be added later; if there are problems with intermediate-depth injection, one or more additional legs could be directionally drilled from the current well bore. Included are the reports of daily drilling records of drill bits, casings, and loggings, and descriptions of cementing, coring, and containment.

Miller, L.G.; Prestwich, S.M.

1979-02-01T23:59:59.000Z

324

Sorbent Injection for Small ESP Mercury Control in Low Sulfur Eastern Bituminous Coal Flue Gas  

SciTech Connect

This project Final Report is submitted to the U.S. Department of Energy (DOE) as part of Cooperative Agreement DE-FC26-03NT41987, 'Sorbent Injection for Small ESP Mercury Control in Low Sulfur Eastern Bituminous Coal Flue Gas.' Sorbent injection technology is targeted as the primary mercury control process on plants burning low/medium sulfur bituminous coals equipped with ESP and ESP/FGD systems. About 70% of the ESPs used in the utility industry have SCAs less than 300 ft2/1000 acfm. Prior to this test program, previous sorbent injection tests had focused on large-SCA ESPs. This DOE-NETL program was designed to generate data to evaluate the performance and economic feasibility of sorbent injection for mercury control at power plants that fire bituminous coal and are configured with small-sized electrostatic precipitators and/or an ESP-flue gas desulfurization (FGD) configuration. EPRI and Southern Company were co-funders for the test program. Southern Company and Reliant Energy provided host sites for testing and technical input to the project. URS Group was the prime contractor to NETL. ADA-ES and Apogee Scientific Inc. were sub-contractors to URS and was responsible for all aspects of the sorbent injection systems design, installation and operation at the different host sites. Full-scale sorbent injection for mercury control was evaluated at three sites: Georgia Power's Plant Yates Units 1 and 2 [Georgia Power is a subsidiary of the Southern Company] and Reliant Energy's Shawville Unit 3. Georgia Power's Plant Yates Unit 1 has an existing small-SCA cold-side ESP followed by a Chiyoda CT-121 wet scrubber. Yates Unit 2 is also equipped with a small-SCA ESP and a dual flue gas conditioning system. Unit 2 has no SO2 control system. Shawville Unit 3 is equipped with two small-SCA cold-side ESPs operated in series. All ESP systems tested in this program had SCAs less than 250 ft2/1000 acfm. Short-term parametric tests were conducted on Yates Units 1 and 2 to evaluate the performance of low-cost activated carbon sorbents for removing mercury. In addition, the effects of the dual flue gas conditioning system on mercury removal performance were evaluated as part of short-term parametric tests on Unit 2. Based on the parametric test results, a single sorbent (e.g., RWE Super HOK) was selected for a 30-day continuous injection test on Unit 1 to observe long-term performance of the sorbent as well as its effects on ESP and FGD system operations as well as combustion byproduct properties. A series of parametric tests were also performed on Shawville Unit 3 over a three-week period in which several activated carbon sorbents were injected into the flue gas duct just upstream of either of the two Unit 3 ESP units. Three different sorbents were evaluated in the parametric test program for the combined ESP 1/ESP 2 system in which sorbents were injected upstream of ESP 1: RWE Super HOK, Norit's DARCO Hg, and a 62:38 wt% hydrated lime/DARCO Hg premixed reagent. Five different sorbents were evaluated for the ESP 2 system in which activated carbons were injected upstream of ESP 2: RWE Super HOK and coarse-ground HOK, Norit's DARCO Hg and DARCO Hg-LH, and DARCO Hg with lime injection upstream of ESP 1. The hydrated lime tests were conducted to reduce SO3 levels in an attempt to enhance the mercury removal performance of the activated carbon sorbents. The Plant Yates and Shawville studies provided data required for assessing carbon performance and long-term operational impacts for flue gas mercury control across small-sized ESPs, as well as for estimating the costs of full-scale sorbent injection processes.

Carl Richardson; Katherine Dombrowski; Douglas Orr

2006-12-31T23:59:59.000Z

325

INJECTING CARBON DIOXIDE INTO UNCONVENTIONAL STORAGE RESERVOIRS...  

NLE Websites -- All DOE Office Websites (Extended Search)

CBM wells over a one-year period Perform a small Huff and Puff test in a Devonian shale gas well Duration: 4 years (October 1, 2011 - September 30, 2015) Research...

326

Histopathological Alterations after Single Epidural Injection of Ropivacaine, Methylprednizolone Acetate, or Contrast Material in Swine  

Science Conference Proceedings (OSTI)

Purpose: The consequences from the injection of different types of drugs in the epidural space remains unknown. Increasing evidence suggests that localized inflammation, fibrosis, and arachnoiditis can complicate sequential epidural blockades, or even epidural contrast injection. We investigate the in vivo effect of epidural injections in the epidural space in an animal model. Materials and Methods: A group of ten male adult pigs, five punctures to each at distinct vertebral interspaces under general anesthesia, were examined, testing different drugs, used regularly in the epidural space (iopamidol, methylprednisolone acetate, ropivacaine). Each site was marked with a percutaneous hook wire marker. Histological analysis of the epidural space, the meninges, and the underlying spinal cord of the punctured sites along with staining for caspase-3 followed 20 days later. Results: The epidural space did not manifest adhesions or any other pathology, and the outer surface of the dura was not impaired in any specimen. The group that had the contrast media injection showed a higher inflammation response compared to the other groups (P = 0.001). Positive staining for caspase-3 was limited to <5% of neurons with all substances used. Conclusion: No proof of arachnoiditis and/or fibrosis was noted in the epidural space with the use of the above-described drugs. A higher inflammation rate was noted with the use of contrast media.

Kitsou, Maria-Chrysanthi; Kostopanagiotou, Georgia; Kalimeris, Konstantinos [University of Athens, 2nd Department of Anesthesiology-Pain Unit, School of Medicine, Attikon University Hospital (Greece); Vlachodimitropoulos, Demetrios [University of Athens, Department of Forensic Medicine, School of Medicine (Greece); Soultanis, Konstantinos [University of Athens, 1st Department of Orthopaedics, School of Medicine, Attikon University Hospital (Greece); Batistaki, Chrysanthi [University of Athens, 2nd Department of Anesthesiology-Pain Unit, School of Medicine, Attikon University Hospital (Greece); Kelekis, Alexis, E-mail: akelekis@med.uoa.gr [University of Athens, 2nd Radiology Department, Attikon University Hospital (Greece)

2011-12-15T23:59:59.000Z

327

Experimental comparison of hot water/propane injection to steam/propane injection for recovery of heavy oil.  

E-Print Network (OSTI)

??Generating enough heat to convert water into steam is a major expense for projects that inject steam into reservoirs to enhance hydrocarbon recovery. If the (more)

Nesse, Thomas

2005-01-01T23:59:59.000Z

328

Analytical steam injection model for layered systems  

SciTech Connect

Screening, evaluation and optimization of the steam flooding process in homogeneous reservoirs can be performed by using simple analytical predictive models. In the absence of any analytical model for layered reservoirs, at present, only numerical simulators can be used. And these are expensive. In this study, an analytical model has been developed considering two isolated layers of differing permeabilities. The principle of equal flow potential is applied across the two layers. Gajdica`s (1990) single layer linear steam drive model is extended for the layered system. The formulation accounts for variation of heat loss area in the higher permeability layer, and the development of a hot liquid zone in the lower permeability layer. These calculations also account for effects of viscosity, density, fractional flow curves and pressure drops in the hot liquid zone. Steam injection rate variations in the layers are represented by time weighted average rates. For steam zone calculations, Yortsos and Gavalas`s (1981) upper bound method is used with a correction factor. The results of the model are compared with a numerical simulator. Comparable oil and water flow rates, and breakthrough times were achieved for 100 cp oil. Results with 10 cp and 1000 cp oils indicate the need to improve the formulation to properly handle differing oil viscosities.

Abdual-Razzaq; Brigham, W.E.; Castanier, L.M.

1993-08-01T23:59:59.000Z

329

Bibliography: injection technology applicable to geothermal utilization  

DOE Green Energy (OSTI)

This bibliography cites 500 documents that may be helpful in planning, analysis, research, and development of the various aspects of injection technology in geothermal applications. These documents include results from government research; development, demonstration, and commercialization programs; selected references from the literature; symposia; references from various technical societies and installations; reference books; reviews; and other selected material. The cited references are from (1) subject searching, using indexing, storage, and retrieval information data base of the Department of Energy's Technical Information Center's on-line retrieval system, RECON; (2) searches of references from the RECON data base, of work by authors known to be active in the field of geothermal energy research and development; (3) subject and author searches by the computerized data storage and retrieval system of Chemical Abstracts, American Chemical Society, Washington, DC; and (4) selected references from texts and reviews on this subject. Each citation includes title, author, author affiliation, date of publication, and source. The citations are listed in chronological order (most recent first) in each of the subject categories for which this search was made. The RECON accession number is also given.

Darnell, A.J.; Eichelberger, R.L.

1982-03-19T23:59:59.000Z

330

Coal combustion under conditions of blast furnace injection. Technical report, 1 December 1992--28 February 1993  

SciTech Connect

A potentially new use for Illinois coal is its use as a fuel injected into a blast furnace to produce molten iron as the first step in steel production. Because of its increasing cost and decreasing availability, metallurgical coke is now being replaced by coal injected at the tuyere area of the furnace where the blast air enters. The purpose of this study is to evaluate the combustion of coal during the blast furnace injection process and to delineate the optimum properties of the feed coal. This investigation is significant to the use of Illinois coal in that the limited research to date suggests that coals of low fluidity and moderate to high sulfur and chlorine contents are suitable feedstocks for blast furnace injection. This proposed study is unique in that it will be the first North American effort to directly determine the nature of the combustion of coal injected into a blast furnace. The Amanda furnace of Armco is the only one in North America currently using coal injection and is, therefore, the only full scale testing facility available. During this quarter complete petrographic analyses of all of the samples so far collected were completed.

Crelling, J.C. [Southern Illinois Univ., Carbondale, IL (United States). Dept. of Geology; Case, E.R. [Armco, Inc., Middletown, OH (United States). Research and Technology Div.

1993-05-01T23:59:59.000Z

331

Determination of Zinc-Based Additives in Lubricating Oils by Flow-Injection Analysis with Flame-AAS Detection Exploiting Injection with a Computer-Controlled Syringe  

E-Print Network (OSTI)

A flow-injection system is proposed for the determination of metal-based additives in lubricating oils. The system, operating under computer control uses a motorised syringe for measuring and injecting the oil sample (200 L) in a kerosene stream, where it is dispersed by means of a packed mixing reactor and carried to an atomic absorption spectrometer which is used as detector. Zinc was used as model analyte. Two different systems were evaluated, one for low concentrations (range 010 ppm) and the second capable of providing higher dilution rates for high concentrations (range 0.02%0.2 % w/w). The sampling frequency was about 30 samples/h. Calibration curves fitted a second-degree regression model (r 2 = 0.996). Commercial samples with high and low zinc levels were analysed by the proposed method and the results were compared with those obtained with the standard ASTM method. The t test for mean values showed no significant differences at the 95 % confidence level. Precision (RSD%) was better than 5 % (2 % typical) for the high concentrations system. The carryover between successive injections was found to be negligible. 1.

Gustavo Pignalosa; Moiss Knochen; Noel Cabrera

2004-01-01T23:59:59.000Z

332

Coal-fueled diesel technology development -- Fuel injection equipment for coal-fueled diesel engines  

DOE Green Energy (OSTI)

Because of the abrasive and corrosive nature of coal water slurries, the development of coal-fueled diesel engine technology by GE-Transportation Systems (GE-TS) required special fuel injection equipment. GE-Corporate Research and Development (GE-CRD) undertook the design and development of fuel injectors, piston pumps, and check valves for this project. Components were tested at GE-CRD on a simulated engine cylinder, which included a cam-actuated jerk pump, prior to delivery to GE-TS for engine testing.

Johnson, R.N.; Hayden, H.L.

1994-01-01T23:59:59.000Z

333

Adaptable Inverter for Injection of Fuel Cell and Photovoltaic Power  

E-Print Network (OSTI)

important to apply renewable energies and efficient technologies. For power injection of photovoltaic with different energy sources such as photovoltaic, fuel cell and battery. It is possible to adjust active inverter. These inverters for injection of photovoltaic energy are developed only for this purpose

Kulig, Stefan

334

An immiscible WAG injection project in the Kuparuk River Unit  

SciTech Connect

Immiscible water-alternating-gas (WAG) injection has been successfully used in the Kuparuk River Unit as a means of controlling excess gas production. Additionally, simulation results have indicated that WAG injection can increase economic oil recovery by improving waterflood conformance. WAG recovery mechanisms, simulation results, field performance, and field surveillance are discussed.

Champion, J.H.; Sheldon, J.B.

1989-05-01T23:59:59.000Z

335

PROGRESS WITH NSLS-II INJECTION STRAIGHT SECTION DESIGN  

SciTech Connect

The NSLS-II injection straight section (SR) consists of pulsed and DC bumps, septa system, beam trajectory correction and diagnostics systems. In this paper we discuss overall injection straight layout, preliminary element designs, specifications for the pulsed and DC magnets and their power supplies, vacuum devices and chambers and diagnostics devices. Prior to selecting the current 'conventional' design of the injection straight section we analyzed an option of injection via pulsed multipole pioneered at PF-AR. We found that this promising approach was not suited to the NSLS-II storage ring optics, since it would require a impractically compact arrangement of the injection straight section components and a complex modification of the transport line optics due to the strong focusing of the injected beam passing off the pulsed multipole axis. In addition, the requirement for a small injection transient of the stored beam orbit severely constrains the vertical alignment tolerance of the pulsed multipole. The design of the NSLS-II injection straight section is now completed with exception of transition chamber details, which will be adjusted to accommodate the actual layouts of the pulsed magnets.

Shaftan, T.; Blednykh, A.; Casey, B.; Dalesio, B.; Faussete, R.; Ferreira, M.; Fliller, R.; Ganetis, G.; Heese, R.; Hseuh, H.-C.; Job, P.K.; Johnson, E.; Kosciuk, B.; Kowalski, S.; Padrazo, D.; Parker, B.; Pinayev, I.; Sharma, S.; Singh, O.; Spataro, C.

2011-03-28T23:59:59.000Z

336

Medium energy pitch angle distribution during substorm injected electron clouds  

E-Print Network (OSTI)

Medium energy pitch angle distribution during substorm injected electron clouds A. A° snes,1 J, N. ?stgaard, and M. Thomsen (2005), Medium energy pitch angle distribution during substorm injected to obtain pitch angle resolved electron distribution data for measurements at energies 10 eV to 47 keV. [3

Bergen, Universitetet i

337

Final Report: Particulate Emissions Testing, Unit 1, Potomac...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

(PM), the first during normal unit operation and the second with the injection of TRONA upstream of hot side ESP fields. All tests were completed while Unit 1 was operating...

338

Chesapeake Testing  

Science Conference Proceedings (OSTI)

... Send E-Mail to NVLAP at: NVLAP@nist.gov. Personal Body Armor Testing. ... 7 Ballistic Resistance of Body Armor, Section 7, Ballistic Test Methods. ...

2014-01-03T23:59:59.000Z

339

Structural Testing  

DOE Green Energy (OSTI)

Structural testing at the National Wind Technology Center (NWTC) offers many benefits to wind turbine companies. NWTC includes a new high bay large enough to test any blade expected during the next 5 years. (There are four test bays.) In 1995, NWTC developed a saphisticated data acquisition system, known as the Blade Structural Testing Real-time Acquisition Interface Network (BSTRAIN), to monitor structural testing through 24-hour continuous video surveillance. NWTC recommends ultimate static-strength and fatigue testing, with nondestructive testing in some cases (vibrational testing is covered in a separate information sheet).

NONE

1996-06-01T23:59:59.000Z

340

U-174: Serendipity Unspecified SQL Injection Vulnerability | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4: Serendipity Unspecified SQL Injection Vulnerability 4: Serendipity Unspecified SQL Injection Vulnerability U-174: Serendipity Unspecified SQL Injection Vulnerability May 22, 2012 - 7:00am Addthis PROBLEM: Serendipity Unspecified SQL Injection Vulnerability PLATFORM: 1.6.1 and prior versions ABSTRACT: A vulnerability was reported in Serendipity. A remote user can inject SQL commands. Reference Links: SecurityTracker Alert ID: 1027079 Secunia Advisory SA49234 CVE-2012-2762 IMPACT ASSESSMENT: Medium Discussion: The 'include/functions_trackbacks.inc.php' script does not properly validate user-supplied input. A remote user can supply a specially crafted parameter value to execute SQL commands on the underlying database. Impact: A remote user can execute SQL commands on the underlying database. Solution: The vendor has issued a fix (1.6.2).

Note: This page contains sample records for the topic "insar injectivity test" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

V-170: Apache Subversion Hook Scripts Arbitrary Command Injection  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

0: Apache Subversion Hook Scripts Arbitrary Command Injection 0: Apache Subversion Hook Scripts Arbitrary Command Injection Vulnerability V-170: Apache Subversion Hook Scripts Arbitrary Command Injection Vulnerability June 4, 2013 - 12:17am Addthis PROBLEM: Apache Subversion Hook Scripts Arbitrary Command Injection Vulnerability PLATFORM: Apache Subversion 1.x ABSTRACT: A vulnerability has been reported in Apache Subversion. REFERENCE LINKS: Apache Original Advisory Secunia Advisory SA53727 CVE-2013-2088 IMPACT ASSESSMENT: Medium DISCUSSION: The vulnerability is caused due to an input validation error in the svn-keyword-check.pl hook script while processing filenames and can be exploited to inject and execute arbitrary shell commands via a specially crafted request. Successful exploitation requires that contrib scripts are used on the

342

U-251: Bugzilla LDAP Injection and Information Disclosure Vulnerabilities |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1: Bugzilla LDAP Injection and Information Disclosure 1: Bugzilla LDAP Injection and Information Disclosure Vulnerabilities U-251: Bugzilla LDAP Injection and Information Disclosure Vulnerabilities September 5, 2012 - 6:00am Addthis PROBLEM: Bugzilla LDAP Injection and Information Disclosure Vulnerabilities PLATFORM: Bugzilla 2.x Bugzilla 3.x Bugzilla 4.x ABSTRACT: Bugzilla is prone to an LDAP-injection vulnerability and an information-disclosure vulnerability reference LINKS: Bugzilla Homepage Bugzilla Security Advisory Bugtraq ID: 55349 Secunia Advisory SA50433 CVE-2012-3981 CVE-2012-4747 IMPACT ASSESSMENT: Medium Discussion: A vulnerability and a security issue have been reported, which can be exploited by malicious people to disclose potentially sensitive information and manipulate certain data. 1) Input passed via the username is not properly escaped before being used

343

Underground Injection Control (West Virginia) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Injection Control (West Virginia) Injection Control (West Virginia) Underground Injection Control (West Virginia) < Back Eligibility Utility Fed. Government Commercial Agricultural Investor-Owned Utility State/Provincial Govt Industrial Construction Municipal/Public Utility Local Government Residential Installer/Contractor Rural Electric Cooperative Tribal Government Low-Income Residential Schools Retail Supplier Institutional Multi-Family Residential Systems Integrator Fuel Distributor Nonprofit General Public/Consumer Transportation Program Info State West Virginia Program Type Siting and Permitting Provider Department of Environmental Protection This rule set forth criteria and standards for the requirements which apply to the State Underground Injection Control Program (U.I.C.). The UIC permit program regulates underground injections by 5 classes of wells. All owners

344

Coal combustion under conditions of blast furnace injection. [Quarterly] technical report, 1 December 1993--28 February 1994  

SciTech Connect

A potentially new use for Illinois coal is its use as a fuel injected into a blast furnace to produce molten iron as the first step in steel production. Because of its increasing cost and decreasing availability, metallurgical coke is now being replaced by coal injected at the tuyere area of the furnace where the blast air enters. The purpose of this study is to evaluate the combustion of coal during the blast furnace injection process and to delineate the optimum properties of the feed coal. This proposal is a follow-up to one funded for the 1992--1993 period. It is intended to complete the study already underway with the Armco Inc. Steel Company and to initiate a new cooperative study along somewhat similar lines with the Inland Steel Company. The results of this study will lead to the development of a testing and evaluation protocol that will give a unique and much needed understanding of the behavior of coal in the injection process and prove the potential of Illinois coals for such use. During this quarter a sample of the feed coal that is being used for injection into the No. 7 Blast Furnace of Inland Steel has been analyzed petrographically and compared to both the Herrin No. 6 coal and Armco feed coal. Additional characterization is underway and an advanced program of pyrolysis and reactivity testing has been initiated.

Crelling, J.C. [Southern Illinois Univ., Carbondale, IL (United States). Dept. of Geology

1994-06-01T23:59:59.000Z

345

Blast furnace granular coal injection project. Annual report, January--December 1993  

SciTech Connect

This initial annual report describes the Blast Furnace Granular Coal Injection project being implemented at Bethlehem Steel Corporation`s (BSC) Burns Harbor, Indiana, plant. This installation will be the first in the United States to employ British Steel technology that uses granular coal to provide part of the fuel requirement of blast furnaces. The project will demonstrate/assess a broad range of technical/economic issues associated with the use of coal for this purpose. These include: coal grind size, coal injection rate, coal source (type) and blast furnace conversion method. Preliminary Design (Phase 1) began in 1991 with detailed design commencing in 1993. Construction at Burns Harbor (Phase 2) began in August 1993. Construction is expected to complete in the first quarter of 1995 which will be followed by the demonstration test program (Phase 3). Progress is described.

1994-06-01T23:59:59.000Z

346

Injection and energy recovery in fractured geothermal reservoirs  

DOE Green Energy (OSTI)

Numerical studies of the effects of injection on the behavior of production wells completed in fractured two-phase geothermal reservoirs are presented. In these studies the multiple-interacting-continua (MINC) method is employed for the modeling of idealized fractured reservoirs. Simulations are carried out for a five-spot well pattern with various well spacings, fracture spacings, and injection fractions. The production rates from the wells are calculated using a deliverability model. The results of the studies show that injection into two-phase fractured reservoirs increases flow rates and decreases enthalpies of producing wells. These two effects offset each other so that injection tends to have small effects on the usable energy output of production wells in the short term. However, if a sufficiently large fraction of the produced fluids is injected, the fracture system may become liquid-filled and an increased steam rate is obtained. Our studies show that injection greatly increases the long-term energy output from wells, as it helps extract heat from the resrvoir rocks. If a high fraction of the produced fluids is injected, the ultimate energy recovery will increase manyfold.

Bodvarsson, G.S.; Pruess, K.; O'Sullivan, M.J.

1983-01-01T23:59:59.000Z

347

Electron bunch injection at an angle into a laser wakefield  

E-Print Network (OSTI)

External injection of electron bunches longer than the plasma wavelength in a laser wakefield accelerator can lead to the generation of femtosecond ultrarelativistic bunches with a couple of percent energy spread. Extensive study has been done on external electron bunch (e.g. one generated by a photo-cathode rf linac) injection in a laser wakefield for different configurations. In this paper we investigate a new way of external injection where the electron bunch is injected at a small angle into the wakefield. This way one can avoid the ponderomotive scattering as well as the vacuum-plasma transition region, which tend to destroy the injected bunch. In our simulations, the effect of the laser pulse dynamics is also taken into account. It is shown that injection at an angle can provide compressed and accelerated electron bunches with less than 2% energy spread. Another advantage of this scheme is that it has less stringent requirements in terms of the size of the injected bunch and there is the potential to tr...

Luttikhof, M J H; Van Goor, F A; Boller, K -J

2008-01-01T23:59:59.000Z

348

Test Diversity  

E-Print Network (OSTI)

This paper describes a novel method for measuring the degree to which a set of test cases executes a given program in diverse ways with respect to the two fundamental programming concepts: control and data. Test Diversity is a method for measuring the variety of software control flow and data flow, comprising of four new measures: conditional diversity, data diversity, standard deviation of diversity, and test orthogonality. These closely-related measures could be used to evaluate the test effectiveness and the test-effort distribution of a test suite. The Diversity Analyzer is a novel industrial-strength testing tool that can currently perform diversity analysis on software written in C/C++/C#/VB in Windows and.NET environments. The Diversity Analyzer is used to evaluate the fault-detection effectiveness of Test Diversity on various types of industrial projects. Key Words: testing tools, verification, theory, experimentation, conditional diversity, data diversity, standard deviation,

Borislav Nikolik

2006-01-01T23:59:59.000Z

349

Final Technical Resource Confirmation Testing at the Raft River Geothermal Project, Cassia County, Idaho  

Science Conference Proceedings (OSTI)

Incorporates the results of flow tests for geothermal production and injection wells in the Raft River geothermal field in southern Idaho. Interference testing was also accomplished across the wellfield.

Glaspey, Douglas J.

2008-01-30T23:59:59.000Z

350

Spin Injection Across a Heterojunction: A Ballistic Picture  

SciTech Connect

Spin injection across heterojunctions plays a decisive role in the new field of spintronics. Within the ballistic transport regime, we state a general expression for the spin-injection rate in a heterojunction made of two ballistic electrodes. Both the spin-orbit interaction and interface scattering effect are taken into account. Our model is consistent with the well-documented results of ferromagnetic-metal junctions. It explains the recent experimental results of a dilute-magnetic-semiconductor/semiconductor junction and predicts solutions to enhance the spin-injection rate across a ferromagnetic-semiconductor junction.

Hu, C.-M.; Matsuyama, T.

2001-08-06T23:59:59.000Z

351

Fluid injection profiles: modern analysis of wellbore temperature survey  

DOE Green Energy (OSTI)

Exact and approximate solutions for heat flow in a fluid injection well are presented. By using the approximate results, temperature surveys can be quickly analyzed in the field, and the well depths where fluids leave and the departing flow rates at these depths can be precisely determined. Although this method eliminates the need for indigenous and post injection shut-in temperatures, several surveys must be taken just before and during the injection period which can be as short as several hours. In the application described the method was used to locate the depths where hydraulic fractures were initiated in a hot dry rock geothermal well.

Murphy, H.D.

1977-01-01T23:59:59.000Z

352

Compendium of Regulatory Requirements Governing Underground Injection of Drilling Wastes  

Science Conference Proceedings (OSTI)

This report provides a comprehensive compendium of the regulatory requirements governing the injection processes used for disposing of drilling wastes; in particular, for a process referred to in this report as slurry injection. The report consists of a narrative discussion of the regulatory requirements and practices for each of the oil- and gas-producing states, a table summarizing the types of injection processes authorized in each state, and an appendix that contains the text of many of the relevant state regulations and policies.

Puder, Markus G.; Bryson, Bill; Veil, John A.

2003-03-03T23:59:59.000Z

353

Steam-injected gas turbines uneconomical with coal gasification equipment  

SciTech Connect

Researchers at the Electric Power Research Institute conducted a series of engineering and economic studies to assess the possibility of substituting steam-injected gas (STIG) turbines for the gas turbines currently proposed for use in British Gas Corporation (BGC)/Lurgi coal gasification-combined cycle plants. The study sought to determine whether steam-injected gas turbines and intercooled steam-injected gas turbines, as proposed by General Electric would be economically competitive with conventional gas and steam turbines when integrated with coal gasification equipment. The results are tabulated in the paper.

1986-09-01T23:59:59.000Z

354

Pressurized feed-injection spray-forming apparatus  

SciTech Connect

A spray apparatus and method for injecting a heated, pressurized liquid in a first predetermined direction into a pressurized gas flow that is flowing in a second predetermined direction, to provide for atomizing and admixing the liquid with the gas to form a two-phase mixture. A valve is also disposed within the injected liquid conduit to provide for a pulsed injection of the liquid and timed deposit of the atomized gas phase. Preferred embodiments include multiple liquid feed ports and reservoirs to provide for multiphase mixtures of metals, ceramics, and polymers.

Berry, Ray A. (Idaho Falls, ID); Fincke, James R. (Idaho Falls, ID); McHugh, Kevin M. (Idaho Falls, ID)

1995-01-01T23:59:59.000Z

355

CarbFix CO2 Injection Pilot Project, J. M. Matter, M. Stute & W. Broecker  

E-Print Network (OSTI)

Fix Injection Site #12;A Conceptual Carbonation Model Injec8on well: CO2 fully dissolvedCarbFix CO2 Injection Pilot Project, Iceland J. M. Matter, M. Stute & W. Broecker Lamont Pétursson #12;CarbFix Injection Site #12;CarbFix CO2 Injection Site #12;CarbFix Injection Site 2

356

Economics and analysis of the miscible CO/sub 2/ injection project, Granny's Creek field, West Virginia  

Science Conference Proceedings (OSTI)

The use of carbon dioxide (CO/sub 2/) in a tertiary oil recovery pilot in the Granny's Creek field, West Virginia, was started in 1976. At first the CO/sub 2/ was injected into the Pocono Big Injun sand at four wells at the corners of an approximately square area of 6.7 acres. The CO/sub 2/ was injected as a liquid, and the pilot portion of the reservoir was maintained at or above miscible pressure. Production was taken from a well inside the square pilot area and from eight wells outside the area. The test began with injection of water to increase reservoir pressure to more than the miscibility pressure. Injection started with CO/sub 2/ alone, then alternate slugs of CO/sub 2/ and water, then CO/sub 2/, alone, and finally water alone was injected. The additional oil recovery was 8,681 bbl for an injection total of 19.76 million lb of CO/sub 2/ for a ratio of 19,626 cu ft per bbl. A second or minipilot in which the injection was in the lower or C zone of the Big Injun sand resulted in 2,007.9 bbl of additional oil through September 1980 from the injection of 4.24 million lb of CO/sub 2/ for a ratio of 18,192 cu ft per bbl. The CO/sub 2/ spread quickly across the southern 350 acres of the field and confinement was not attained. The sales price of the oil after royalty and taxes is probably about equal to the most optimistic cost of the CO/sub 2/ per barrel of additional oil at the present time and far less than a more reasonable cost for the CO/sub 2/. Production of additional oil in each case decreased sharply after injection of CO/sub 2/ was stopped so there appeared to be no benefits over an extended period of time from the injection of CO/sub 2/.

Smith, R.V.; Watts, R.J.; Burtch, F.W.

1983-04-01T23:59:59.000Z

357

CO2 Injection in Kansas Oilfield Could Greatly Increase Production,  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

CO2 Injection in Kansas Oilfield Could Greatly Increase Production, CO2 Injection in Kansas Oilfield Could Greatly Increase Production, Permanently Store Carbon Dioxide, DOE Study Says CO2 Injection in Kansas Oilfield Could Greatly Increase Production, Permanently Store Carbon Dioxide, DOE Study Says August 31, 2011 - 1:00pm Addthis Washington, DC - The feasibility of using carbon dioxide (CO2) injection for recovering between 250 million and 500 million additional barrels of oil from Kansas oilfields has been established in a study funded by the U.S. Department of Energy (DOE). The University of Kansas Center for Research studied the possibility of near-miscible CO2 flooding for extending the life of mature oilfields in the Arbuckle Formation while simultaneously providing permanent geologic storage of carbon dioxide, a major greenhouse gas.

358

one mile underground into a deep saline formation. The injection  

NLE Websites -- All DOE Office Websites (Extended Search)

mile underground into a deep saline formation. The injection, mile underground into a deep saline formation. The injection, which will occur over a three-year period and is slated to start in early 2010, will compress up to 1 million metric tonnes of CO 2 from the ADM ethanol facility into a liquid-like, dense phase. The targeted rock formation, the Mt. Simon Sandstone, is the thickest and most widespread saline reservoir in the Illinois Basin, with an estimated CO 2 storage capacity of 27 to 109 billion metric tonnes. A comprehensive monitoring program, which will be evaluated yearly, will be implemented after the injection to ensure the injected CO 2 is stored safely and permanently. The RCSP Program was launched by the Office of Fossil Energy (FE)

359

Controlled air injection for a fuel cell system  

DOE Patents (OSTI)

A method and apparatus for injecting oxygen into a fuel cell reformate stream to reduce the level of carbon monoxide while preserving the level of hydrogen in a fuel cell system.

Fronk, Matthew H. (Honeove Falls, NY)

2002-01-01T23:59:59.000Z

360

Premixed direct injection nozzle for highly reactive fuels  

Science Conference Proceedings (OSTI)

A fuel/air mixing tube for use in a fuel/air mixing tube bundle is provided. The fuel/air mixing tube includes an outer tube wall extending axially along a tube axis between an inlet end and an exit end, the outer tube wall having a thickness extending between an inner tube surface having a inner diameter and an outer tube surface having an outer tube diameter. The tube further includes at least one fuel injection hole having a fuel injection hole diameter extending through the outer tube wall, the fuel injection hole having an injection angle relative to the tube axis. The invention provides good fuel air mixing with low combustion generated NOx and low flow pressure loss translating to a high gas turbine efficiency, that is durable, and resistant to flame holding and flash back.

Ziminsky, Willy Steve; Johnson, Thomas Edward; Lacy, Benjamin Paul; York, William David; Uhm, Jong Ho; Zuo, Baifang

2013-09-24T23:59:59.000Z

Note: This page contains sample records for the topic "insar injectivity test" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Underground Injection Control Program Rules and Regulations (Rhode Island)  

Energy.gov (U.S. Department of Energy (DOE))

The purpose of this regulation is to preserve the quality of the groundwater of the State and thereby protect groundwater contamination from contamination by discharge from injection wells and...

362

The reduction of supersonic jet noise using pulsed microjet injection  

E-Print Network (OSTI)

This thesis is concerned with the active control of supersonic jet noise using pulsed microjet injection at the nozzle exit. Experimental investigations were carried out using this control method on an ideally expanded ...

Ragaller, Paul Aaron

2007-01-01T23:59:59.000Z

363

The design, manufacturing and use of economically friendly injection molds  

E-Print Network (OSTI)

Much of the polymer manufacturing done today involves the process of injection molding. It can be difficult to gain experience in the art of designing and building tooling for this process outside of industry. The goal of ...

Buchok, Aaron (Aaron J.)

2008-01-01T23:59:59.000Z

364

Non-uniform emission studies of a magnetron injection gun  

E-Print Network (OSTI)

This thesis investigates the experimental measurement and theoretical simulation of the effects of azimuthal emission non-uniformity of a 96 kV, 40 amp magnetron injection gun (MIG) used in a gyrotron. The accomplishments ...

Marchewka, Chad D. (Chad Daniel)

2006-01-01T23:59:59.000Z

365

Cost Estimate of Activated Carbon Injection for Controlling Mercury...  

NLE Websites -- All DOE Office Websites (Extended Search)

mercury reductions of between 60% and 70% at injection rates around 10-15 lbsmillion acf (see Figure 1). Although regression analysis of full-scale ACIESP data shows that it...

366

Lithium pellet injection into high pressure magnetically confined plasmas  

E-Print Network (OSTI)

The ablation of solid pellets injected into high temperature magnetically confined plasmas is characterized by rapid oscillations in the ablation rate, and the formation of field aligned filaments in the ablatant. High ...

Bse, Brock (Brock Darrel)

2010-01-01T23:59:59.000Z

367

Collagen scaffolds and injectable biopolymer gels for cardiac tissue engineering  

E-Print Network (OSTI)

Three-dimensional biomaterial scaffolds have begun to shown promise for cell delivery for cardiac tissue engineering. Although various polymers and material forms have been explored, there is a need for: injectable gels ...

Ng, Karen Kailin

2012-01-01T23:59:59.000Z

368

Underground Injection Control Fee Schedule (West Virginia) | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Injection Control Fee Schedule (West Virginia) Injection Control Fee Schedule (West Virginia) Underground Injection Control Fee Schedule (West Virginia) < Back Eligibility Utility Fed. Government Commercial Agricultural Investor-Owned Utility State/Provincial Govt Industrial Construction Municipal/Public Utility Local Government Residential Installer/Contractor Rural Electric Cooperative Tribal Government Low-Income Residential Schools Retail Supplier Institutional Multi-Family Residential Systems Integrator Fuel Distributor Nonprofit General Public/Consumer Transportation Program Info State West Virginia Program Type Fees Provider Department of Environmental Protection This rule establishes schedules of permit fees for state under-ground injection control permits issued by the Chief of the Office of Water Resources. This rule applies to any person who is required to apply for and

369

NETL: News Release - Illinois CO2 Injection Project Moves Another...  

NLE Websites -- All DOE Office Websites (Extended Search)

5, 2010 Illinois CO2 Injection Project Moves Another Step Forward Baseline Data Important for CCS Project's Planned 2011 Startup Washington, D.C. - The recent completion of a...

370

A study of production/injection data from slim holes and production wells at the Oguni Geothermal Field, Japan  

DOE Green Energy (OSTI)

Production and injection data from slim holes and large-diameter wells at the Oguni Geothermal Field, Japan, were examined in an effort to establish relationships (1) between productivity of large-diameter wells and slim holes, (2) between injectivity and productivity indices and (3) between productivity index and borehole diameter. The production data from Oguni boreholes imply that the mass production from large-diameter wells may be estimated based on data from slim holes. Test data from both large- and small-diameter boreholes indicate that to first order the productivity and the injectivity indices are equal. Somewhat surprisingly, the productivity index was found to be a strong function of borehole diameter; the cause for this phenomenon is not understood at this time.

Garg, S.K.; Combs, J.; Abe, M.

1996-03-01T23:59:59.000Z

371

Injection locked oscillator system for pulsed metal vapor lasers  

SciTech Connect

An injection locked oscillator system for pulsed metal vapor lasers is disclosed. The invention includes the combination of a seeding oscillator with an injection locked oscillator (ILO) for improving the quality, particularly the intensity, of an output laser beam pulse. The present invention includes means for matching the first seeder laser pulses from the seeding oscillator to second laser pulses of a metal vapor laser to improve the quality, and particularly the intensity, of the output laser beam pulse.

Warner, Bruce E. (Livermore, CA); Ault, Earl R. (Dublin, CA)

1988-01-01T23:59:59.000Z

372

Apparatus and method for downhole injection of radioactive tracer  

SciTech Connect

The disclosure relates to downhole injection of radioactive .sup.82 Br and monitoring its progress through fractured structure to determine the nature thereof. An ampule containing granular .sup.82 Br is remotely crushed and water is repeatedly flushed through it to cleanse the instrument as well as inject the .sup.82 Br into surrounding fractured strata. A sensor in a remote borehole reads progress of the radioactive material through fractured structure.

Potter, Robert M. (Los Alamos, NM); Archuleta, Jacobo R. (Espanola, NM); Fink, Conrad F. (Los Alamos, NM)

1983-01-01T23:59:59.000Z

373

Optoelectronic device with nanoparticle embedded hole injection/transport layer  

DOE Patents (OSTI)

An optoelectronic device is disclosed that can function as an emitter of optical radiation, such as a light-emitting diode (LED), or as a photovoltaic (PV) device that can be used to convert optical radiation into electrical current, such as a photovoltaic solar cell. The optoelectronic device comprises an anode, a hole injection/transport layer, an active layer, and a cathode, where the hole injection/transport layer includes transparent conductive nanoparticles in a hole transport material.

Wang, Qingwu (Chelmsford, MA); Li, Wenguang (Andover, MA); Jiang, Hua (Methuen, MA)

2012-01-03T23:59:59.000Z

374

Booster gold beam injection efficiency and beam loss  

SciTech Connect

The Relativistic Heavy Ion Collider (RHIC) at the BNL requires the AGS to provide gold beam with the intensity of 10{sup 9} ions per bunch. Over the years, the Tandem Van de Graaff has provided steadily increasing intensity of gold ion beams to the AGS Booster. However, the gold ion beam injection efficiency at the Booster has been found to decrease with the rising intensity of injected beams. As the result, for Tandem beams of the highest intensity, the Booster late intensity is lower than with slightly lower intensity Tandem beam. In this article, the authors present two experiments associated with the Booster injection efficiency and beam intensity. One experiment looks at the Booster injection efficiency by adjusting the Tandem beam intensity, and another looks at the beam life time while scraping the beam in the Booster. The studies suggest that the gold beam injection efficiency at the AGS Booster is related to the beam loss in the ring, rather than the intensity of injected beam or circulating beam.

Zhang, S.Y.; Ahrens, L.A.

1998-08-01T23:59:59.000Z

375

Pressure buildup during supercritical carbon dioxide injection from a partially penetrating borehole into gas reservoirs  

E-Print Network (OSTI)

the vicinity of the injection well. While a large injectionby pumping it down into an injection well. While the actuala small part of the injection well (typically, a few meters

Mukhopadhyay, S.

2013-01-01T23:59:59.000Z

376

Coupled reservoir-geomechanical analysis of CO2 injection and ground deformations at In Salah, Algeria  

E-Print Network (OSTI)

is centered on one CO 2 injection well and consists of about1.5 km) horizontal injection wells. In an ongoing researchabove active CO 2 injection wells and the uplift pattern

Rutqvist, J.

2010-01-01T23:59:59.000Z

377

Continuous active-source seismic monitoring of CO2 injection in a brine aquifer  

E-Print Network (OSTI)

source deployed in the injection well. We first present thehas two wells, an injection well and a dedicated monitoringa sonic log of the injection well. We assumed the volume

Daley, Thomas M.; Solbau, Ray D.; Ajo-Franklin, Jonathan B.; Benson, Sally M.

2008-01-01T23:59:59.000Z

378

BOOSTER EXTRACTION, BOOSTER-TO-STORAGE RING TRANSPORT AND STORAGE RING INJECTION FOR THE ALS  

E-Print Network (OSTI)

Storage Ring Injection for the ALS M.S. Zisman March 1988Ring Injection for the ALS Michael S. Zisman Exploratoryon the design of the ALS injection system is presented. The

Zisman, M.S.

2010-01-01T23:59:59.000Z

379

Forecast of thermal-hydrological conditions and air injection test results of the single heater test at Yucca Mountain  

E-Print Network (OSTI)

29127, Berkeley, CA, 1990. Forecast of Thermal-HydrologicalDecember 1996 Figures A-l Forecast ofThermal-HydrologicalT I O N A L L A B ORATORY Forecast o f T h e n n a l - H y d

Birkholzer, J.T.

2010-01-01T23:59:59.000Z

380

Forecast of thermal-hydrological conditions and air injection test results of the single heater test at Yucca Mountain  

E-Print Network (OSTI)

core borehole USW UZ-14, USGS, L. Flint Physical properties,borehole USW UZ-7a, USGS, L. Flint Physical properties,USW NRG-7/7A, USGS, L. Flint Lab measurements of density,

Birkholzer, J.T.

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "insar injectivity test" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Enhancing the Use of Coals by Gas Reburning - Sorbent Injection Volume 5 - Guideline Manual  

Science Conference Proceedings (OSTI)

The purpose of the Guideline Manual is to provide recommendations for the application of combined gas reburning-sorbent injection (GR-SI) technologies to pre-NSPS boilers. The manual includes design recommendations, performance predictions, economic projections and comparisons with competing technologies. The report also includes an assessment of boiler impacts. Two full-scale demonstrations of gas reburning-sorbent injection form the basis of the Guideline Manual. Under the U.S. Department of Energy's Clean Coal Technology Program (Round 1), a project was completed to demonstrate control of boiler emissions that comprise acid rain precursors, specifically oxides of nitrogen (NOX) and sulfur dioxide (S02). Other project sponsors were the Gas Research Institute and the Illinois State Department of Commerce and Community Affairs. The project involved d,emonstrating the combined use of Gas Reburning and Sorbent Injection (GR-SI) to assess the air emissions reduction potential of these technologies.. Three potential coal-fired utility boiler host sites were evaluated: Illinois Power's tangentially-fired 71 MWe (net) Hennepin Unit #1, City Water Light and Power's cyclone- fired 33 MWe (gross) Lakeside Unit #7, and Central Illinois Light Company's wall-fired 117 MWe (net) Edwards Unit #1. Commercial demonstrations were completed on the Hennepin and Lakeside Units. The Edwards Unit was removed from consideration for a site demonstration due to retrofit cost considerations. Gas Reburning (GR) controls air emissions of NOX. Natural gas is introduced into the furnace hot flue gas creating a reducing reburning zone to convert NOX to diatomic nitrogen (N,). Overfire air is injected into the furnace above the reburning zone to complete the combustion of the reducing (fuel) gases created in the reburning zone. Sorbent Injection (S1) consists of the injection of dry, calcium-based sorbents into furnace hot flue gas to achieve S02 capture. `At each site where the technologies were to be demonstrated, performance goals were set to achieve air emission reductions of 60 percent for NOX and 50 percent for S02. These performance goals were exceeded during long term demonstration testing. For the tangentially fired unit, NO, emissions were reduced by 67.2?40 and SOZ emissions by 52.6Y0. For the cyclone-fired unit, NO, emissions were reduced by 62.9% and SOZ emissions by 57.9Y0.

None

1998-06-01T23:59:59.000Z

382

Enahancing the Use of Coals by Gas Reburning - Sorbent Injection Volume 5 - Guideline Manual  

Science Conference Proceedings (OSTI)

The purpose of the Guideline Manual is to provide recommendations for the application of combined gas reburning-sorbent injection (GR-SI) technologies to pre-NSPS boilers. The manual includes design recommendations, performance predictions, economic projections and comparisons with competing technologies. The report also includes an assessment of boiler impacts. Two full-scale demonstrations of gas reburning-sorbent injection form the basis of the Guideline Manual. Under the U.S. Department of Energy's Clean Coal Technology Program (Round 1), a project was completed to demonstrate control of boiler emissions that comprise acid rain precursors, specifically oxides of nitrogen (NOX) and sulfur dioxide (S02). Other project sponsors were the Gas Research Institute and the Illinois State Department of Commerce and Community Affairs. The project involved demonstrating the combined use of Gas Reburning and Sorbent Injection (GR-SI) to assess the air emissions reduction potential of these technologies.. Three potential coal-fired utility boiler host sites were evaluated: Illinois Power's tangentially-fired 71 MWe (net) Hennepin Unit W, City Water Light and Power's cyclone- fired 33 MWe (gross) Lakeside Unit #7, and Central Illinois Light Company's wall-fired 117 MWe (net) Edwards Unit #1. Commercial demonstrations were completed on the Hennepin and Lakeside Units. The Edwards Unit was removed from consideration for a site demonstration due to retrofit cost considerations. Gas Reburning (GR) controls air emissions of NOX. Natural gas is introduced into the furnace hot flue gas creating a reducing reburning zone to convert NOX to diatomic nitrogen (N,). Overfire air is injected into the furnace above the reburning zone to complete the combustion of the reducing (fuel) gases created in the reburning zone. Sorbent Injection (S1) consists of the injection of dry, calcium-based sorbents into furnace hot flue gas to achieve S02 capture. At each site where the techno!o@es were to be demonstrated, petiormance goals were set to achieve air emission reductions of 60 percent for NO. and 50 percent for SO2. These performance goals were exceeded during long term demonstration testing. For the tangentially fired unit, NOX emissions were reduced by 67.2% and S02 emissions by 52.6%. For the cyclone-fired unit, NOX emissions were reduced by 62.9% and SOZ emissions by 57.9%.

None

1998-09-01T23:59:59.000Z

383

A three-dimensional laboratory steam injection model allowing in situ saturation measurements. [Comparing steam injection and steam foam injection with nitrogen and without nitrogen  

SciTech Connect

The CT imaging technique together with temperature and pressure measurements were used to follow the steam propagation during steam and steam foam injection experiments in a three dimensional laboratory steam injection model. The advantages and disadvantages of different geometries were examined to find out which could best represent radial and gravity override flows and also fit the dimensions of the scanning field of the CT scanner. During experiments, steam was injected continuously at a constant rate into the water saturated model and CT scans were taken at six different cross sections of the model. Pressure and temperature data were collected with time at three different levels in the model. During steam injection experiments, the saturations obtained by CT matched well with the temperature data. That is, the steam override as observed by temperature data was also clearly seen on the CT pictures. During the runs where foam was present, the saturation distributions obtained from CT pictures showed a piston like displacement. However, the temperature distributions were different depending on the type of steam foam process used. The results clearly show that the pressure/temperature data alone are not sufficient to study steam foam in the presence of non-condensible gas.

Demiral, B.M.R.; Pettit, P.A.; Castanier, L.M.; Brigham, W.E.

1992-08-01T23:59:59.000Z

384

Materials for High-Pressure Fuel Injection Systems  

DOE Green Energy (OSTI)

The high-level goal of this multi-year effort was to facilitate the Advanced Combustion Engine goal of 20% improvement (compared to 2009 baseline) of commercial engine efficiency by 2015. A sub-goal is to increase the reliability of diesel fuel injectors by investigating modelbased scenarios that cannot be achieved by empirical, trial and error methodologies alone. During this three-year project, ORNL developed the methodology to evaluate origins and to record the initiation and propagation of fatigue cracks emanating from holes that were electrodischarge machined (EDM), the method used to form spray holes in fuel injector tips. Both x-ray and neutron-based methods for measuring residual stress at four different research facilities were evaluated to determine which, if any, was most applicable to the fuel injector tip geometry. Owing to the shape and small volumes of material involved in the sack area, residual stress data could only be obtained in the walls of the nozzle a few millimeters back from the tip, and there was a hint of only a small compressive stress. This result was consistent with prior studies by Caterpillar. Residual stress studies were suspended after the second year, reserving the possibility of pursuing this in the future, if and when methodology suitable for injector sacks becomes available. The smooth specimen fatigue behavior of current fuel injector steel materials was evaluated and displayed a dual mode initiation behavior. At high stresses, cracks started at machining flaws in the surface; however, below a critical threshold stress of approximately 800 MPa, cracks initiated in the bulk microstructure, below the surface. This suggests that for the next generation for high-pressure fuel injector nozzles, it becomes increasingly important to control the machining and finishing processes, especially if the stress in the tip approaches or exceeds that threshold level. Fatigue tests were also conducted using EDM notches in the gage sections. Compared to the smooth specimens, EDM notching led to a severe reduction in total fatigue life. A reduction in fatigue life of nearly four orders of magnitude can occur at an EDM notch the approximate size of fuel injector spray holes. Consequently, the initiation and propagation behavior of cracks from small spray holes is relevant for generation of design quality data for the next generation diesel fuel injection devices. This is especially true since the current design methodologies usually rely on the less conservative smooth specimen fatigue testing results, and since different materials can have varying levels of notch fatigue resistance.

Blau, P.; Shyam, A.; Hubbard, C.; Howe, J.; Trejo, R.; Yang, N. (Caterpillar, Inc. Technical Center); Pollard, M. (Caterpillar, Inc. Technical Center)

2011-09-30T23:59:59.000Z

385

Matched boundary extrapolation solutions for CO2 well injection into a saline aquifer  

E-Print Network (OSTI)

interfacesolutionforcarbondioxideinjection intoInterface Solutionfor Carbon Dioxide Injection intoIPCC Special Report on Carbon Dioxide Capture and

Houseworth, J.

2012-01-01T23:59:59.000Z

386

Collection and analyses of physical data for deep injection wells in Florida.  

E-Print Network (OSTI)

??Deep injection wells (DIW) in Florida are regulated by the U.S. Environmental Protection Agency (USEPA) and the state of Florida through the Underground Injection Control (more)

Gao, Jie.

2010-01-01T23:59:59.000Z

387

Laser triggered injection of electrons in a laser wakefield accelerator with the colliding pulse method  

E-Print Network (OSTI)

Laser Triggered Injection ofElectrons in a Laser Wake?eld Accelerator with the CollidingAn injection scheme for a laser wake?eld accelerator that

2004-01-01T23:59:59.000Z

388

U-157: Ruby Mail Gem Directory Traversal and Shell Command Injection...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

57: Ruby Mail Gem Directory Traversal and Shell Command Injection Vulnerabilities U-157: Ruby Mail Gem Directory Traversal and Shell Command Injection Vulnerabilities April 27,...

389

Elastic and elastoplastic finite element simulations of injection into porous reservoirs.  

E-Print Network (OSTI)

??Underground gas injection has attracted remarkable attention for natural gas storage and carbon dioxide (CO2) geologic sequestration applications. Injection of natural gas into depleted hydrocarbon (more)

Chamani, Amin

2013-01-01T23:59:59.000Z

390

Effect of flue gas impurities on the process of injection and storage of carbon dioxide in depleted gas reservoirs  

E-Print Network (OSTI)

Previous experiments - injecting pure CO2 into carbonate cores - showed that the process is a win-win technology, sequestrating CO2 while recovering a significant amount of hitherto unrecoverable natural gas that could help defray the cost of CO2 sequestration. In this thesis, I report my findings on the effect of flue gas ??impurities?? on the displacement of natural gas during CO2 sequestration, and results on unconfined compressive strength (UCS) tests to carbonate samples. In displacement experiments, corefloods were conducted at 1,500 psig and 70??C, in which flue gas was injected into an Austin chalk core containing initially methane. Two types of flue gases were injected: dehydrated flue gas with 13.574 mole% CO2 (Gas A), and treated flue gas (N2, O2 and water removed) with 99.433 mole% CO2 (Gas B). The main results of this study are as follows. First, the dispersion coefficient increases with concentration of ??impurities??. Gas A exhibits the largest dispersion coefficients, 0.18-0.25 cm2/min, compared to 0.13-0.15 cm2/min for Gas B, and 0.15 cm2/min for pure CO2. Second, recovery of methane at breakthrough is relatively high, ranging from 86% OGIP for pure CO2, 74-90% OGIP for Gas B, and 79-81% for Gas A. Lastly, injection of Gas A would sequester the least amount of CO2 as it contains about 80 mole% nitrogen. From the view point of sequestration, Gas A would be least desirable while Gas B appears to be the most desirable as separation cost would probably be cheaper than that for pure CO2 with similar gas recovery. For UCS tests, corefloods were conducted at 1,700 psig and 65??C in such a way that the cell throughput of CO2 simulates near-wellbore throughput. This was achieved through increasing the injection rate and time of injection. Corefloods were followed by porosity measurement and UCS tests. Main results are presented as follows. First, the UCS of the rock was reduced by approximately 30% of its original value as a result of the dissolution process. Second, porosity profiles of rock samples increased up to 2.5% after corefloods. UCS test results indicate that CO2 injection will cause weakening of near-wellbore formation rock.

Nogueira de Mago, Marjorie Carolina

2005-08-01T23:59:59.000Z

391

Illinois. The injection well is being drilled into a test area...  

NLE Websites -- All DOE Office Websites (Extended Search)

option for CO 2 storage. This is the first drilling into the Mount Simon Sandstone since oil and gas exploratory drilling was conducted some 15 to 40 years ago. Drilling...

392

BOOSTER GOLD BEAM INJECTION EFFICIENCY AND BEAM LOSS  

SciTech Connect

The Relativistic Heavy Ion Collider (RHIC) at the BNL requires the AGS to provide Gold beam with the intensity of 10{sup 9} ions per bunch. Over the years, the Tandem Van de Graaff has provided steadily increasing intensity of gold ion beams to the AGS Booster. However, the gold beam injection efficiency at the Booster has been found to decrease with the rising intensity of injected beams. As the result, for Tandem beams of the highest intensity, the Booster late intensity is lower than with slightly lower intensity Tandem beam. In this article, the authors present two experiments associated with the Booster injection efficiency and beam intensity. One experiment looks at the Booster injection efficiency by adjusting the Tandem beam intensity, and another looks at the beam life time while scraping the beam in the Booster. The studies suggest that the gold beam injection efficiency at the AGS Booster is related to the beam loss in the ring, rather than the intensity of injected beam or circulating beam. A close look at the effect of the lost gold ion at the Booster injection leads to the prediction that the lost gold ion creates large number of positive ions, and even larger number of electrons. The lost gold beam is also expected to create large numbers of neutral particles. In 1998 heavy ion run, the production of positive ions and electrons due to the lost gold beam has been observed. Also the high vacuum pressure due to the beam loss, presumably because of the neutral particles it created, has been measured. These results will be reported elsewhere.

ZHANG,S.Y.; AHRENS,L.A.

1998-06-22T23:59:59.000Z

393

Doublet Tracer Testing in Klamath Falls, Oregon  

DOE Green Energy (OSTI)

A tracer test was carried out in a geothermal doublet system to study the injection behavior of a developed reservoir known to be fractured. The doublet produces about 320 gpm of 160 F water that is used for space heating and then injected; the wells are spaced 250 ft apart. Tracer breakthrough was observed in 2 hours and 45 minutes in the production well, indicating fracture flow. However, the tracer concentrations were low and indicated porous media flow; the tracers mixed with a reservoir volume much larger than a fracture.

Gudmundsson, J.S.; Johnson, S.E.; Horne, R.N.; Jackson, P.B.; Culver, G.G.

1983-12-15T23:59:59.000Z

394

TESTING TECHNIQUE  

Science Conference Proceedings (OSTI)

... The cooling bath should ... When testing super-high energy level specimens ... upon the resolution of the scale or readout device at the low end and the ...

2012-10-09T23:59:59.000Z

395

Test Methods  

Science Conference Proceedings (OSTI)

... of the robot, operator control unit (OCU), payload, and batteries Tools needed ... this test method is to quantitatively evaluate the battery capacity per ...

2010-10-05T23:59:59.000Z

396

Characterizing the Effects of Air Injection on Compressor Performance for Use in Active Control of Rotating Stall  

E-Print Network (OSTI)

Previous work has developed an air injection controller for rotating stall based on the idea of a shifting compressor characteristic and the Moore--Greitzer three state compressor model. In order to demonstrate this form of control experimentally, a series of open loop tests were performed to measure the performance characteristics of a low speed axial flow compression system when air is injected upstream of the rotor face. The position of the air injection port relative to the hub and the rotor face and the angle relative to the mean axial flow were varied. The tests show that the injection of air has drastic effects on the stalling mass flow rate and on the size of the hysteresis loop associated with rotating stall. The stalling mass flow rate was decreased by 10% and the hysteresis loop was completely eliminated under some conditions. The results of the open loop parametric study were then used to implement a closed loop control strategy based on a shifting characteristic. 1 Introdu...

Robert Behnken; Mina Leung; Richard M. Murray

1997-01-01T23:59:59.000Z

397

NOx Sensor for Direct Injection Emission Control  

DOE Green Energy (OSTI)

The Electricore/Delphi team continues to leverage the electrochemical planar sensor technology that has produced stoichiometric planar and wide range oxygen sensors as the basis for development of a NOx sensor. Zirconia cell technology with an integrated heater will provide the foundation for the sensor structure. Proven materials and packaging technology will help to ensure a cost-effective approach to the manufacture of this sensor. The electronics technique and interface is considered to be an area where new strategies need to be employed to produce higher S/N ratios of the NOx signal with emphasis on signal stability over time for robustness and durability Both continuous mode and pulse mode control techniques are being evaluated. Packaging the electronics requires careful design and circuit partitioning so that only the necessary signal conditioning electronics are coupled directly in the wiring harness, while the remainder is situated within the ECM for durability and costs reasons. This task continues to be on hold due to the limitation that the definition of the interface electronics was unavailable until very late in the project. The sense element is based on the amperometric method utilizing integrated alumina and zirconia ceramics. Precious metal electrodes are used to form the integrated heater, the cell electrodes and leads. Inside the actual sense cell structure, it is first necessary to separate NOx from the remaining oxygen constituents of the exhaust, without reducing the NOx. Once separated, the NOx will be measured using a measurement cell. Development or test coupons have been used to facilitate material selection and refinement, cell, diffusion barrier, and chamber development. The sense element currently requires elaborate interconnections. To facilitate a robust durable connection, mechanical and metallurgical connections are under investigation. Materials and process refinements continue to play an important role in the development of the sensor.

Betteridge, William J

2006-02-28T23:59:59.000Z

398

Analysis of PWR RCS Injection Strategy During Severe Accident  

Science Conference Proceedings (OSTI)

Reactor coolant system (RCS) injection is an important strategy for severe accident management of a pressurized water reactor (PWR) system. Maanshan is a typical Westinghouse PWR nuclear power plant (NPP) with large, dry containment. The severe accident management guideline (SAMG) of Maanshan NPP is developed based on the Westinghouse Owners Group (WOG) SAMG.The purpose of this work is to analyze the RCS injection strategy of PWR system in an overheated core condition. Power is assumed recovered as the vessel water level drops to the bottom of active fuel. The Modular Accident Analysis Program version 4.0.4 (MAAP4) code is chosen as a tool for analysis. A postulated station blackout sequence for Maanshan NPP is cited as a reference case for this analysis. The hot leg creep rupture occurs during the mitigation action with immediate injection after power recovery according to WOG SAMG, which is not desired. This phenomenon is not considered while developing the WOG SAMG. Two other RCS injection methods are analyzed by using MAAP4. The RCS injection strategy is modified in the Maanshan SAMG. These results can be applied for typical PWR NPPs.

Wang, S.-J. [Institute of Nuclear Energy Research, Taiwan (China); Chiang, K.-S. [Institute of Nuclear Energy Research, Taiwan (China); Chiang, S.-C. [Taiwan Power Company, Taiwan (China)

2004-05-15T23:59:59.000Z

399

ACOUSTICAL TESTING SERVICES TEST METHOD ...  

Science Conference Proceedings (OSTI)

... IEC 60704-2-3 Household and similar electrical appliances - Test code for ... noise emitted and structure-borne vibration induced by small air- moving ...

2013-05-06T23:59:59.000Z

400

Engines - Spark Ignition Engines - Direct Injection - Omnivorous Engine  

NLE Websites -- All DOE Office Websites (Extended Search)

Direct Injection, Spark-Ignited Engines Direct Injection, Spark-Ignited Engines Omnivorous Engine Omnivorous Engine Setup Omnivorous Engine Setup New engine technology has made possible engines that will operate on a wide variety of fuel inputs, from gasoline to naptha to ethanol to methanol, without driver intervention. Although flexible fuel vehicles have been produced in the millions, their engines have always been optimized for gasoline operation while accepting significant performance and efficiency degradations when using the alternative fuel. This project seeks to combine in-cylinder measurement technology, and advanced controls to optimize spark timing, the quantity and timing of injected fuel, to produce an "omnivorous engine"--one that will be able to run on any liquid spark ignition fuel with optimal efficiency and low

Note: This page contains sample records for the topic "insar injectivity test" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

PHYSICS PROCESSES IN DISRUPTION MITIGATION USING MASSIVE NOBLE GAS INJECTION  

SciTech Connect

Methods for detecting imminent disruptions and mitigating disruption effects using massive injection of noble gases (He, Ne, or Ar) have been demonstrated on the DIII-D tokamak [1]. A jet of high injected gas density (> 10{sup 24} m{sup -3}) and pressure (> 20 kPa) penetrates the target plasma at the gas sound speed ({approx}300-500 m/s) and increases the atom/ion content of the plasma by a factor of > 50 in several milliseconds. UV line radiation from the impurity species distributes the plasma energy uniformly on the first wall, reducing the thermal load to the divertor by a factor of 10. Runaway electrons are almost completely eliminated by the large density of free and bound electrons supplied by the gas injection. The small vertical plasma displacement before current quench and high ratio of current decay rate to vertical growth rate result in a 75% reduction in peak halo current amplitude and attendant forces.

D.A. HUMPHREYS; D.G. WHYTE; T.C. JERNIGAN; T.E.EVANS; D.S. GRAY; E.M. HOLLMANN; A.W. HYATT; A.G. KELLMAN; C.J. LASNIER; P.B. PARKS; P.L. TAYLOR

2002-07-01T23:59:59.000Z

402

Numerical modeling of water injection into vapor-dominatedgeothermal reservoirs  

SciTech Connect

Water injection has been recognized as a powerful techniquefor enhancing energy recovery from vapor-dominated geothermal systemssuch as The Geysers. In addition to increasing reservoir pressures,production well flow rates, and long-term sustainability of steamproduction, injection has also been shown to reduce concentrations ofnon-condensible gases (NCGs) in produced steam. The latter effectimproves energy conversion efficiency and reduces corrosion problems inwellbores and surface lines.This report reviews thermodynamic andhydrogeologic conditions and mechanisms that play an important role inreservoir response to water injection. An existing general-purposereservoir simulator has been enhanced to allow modeling of injectioneffects in heterogeneous fractured reservoirs in three dimensions,including effects of non-condensible gases of different solubility.Illustrative applications demonstrate fluid flow and heat transfermechanisms that are considered crucial for developing approaches to insitu abatement of NCGs.

Pruess, Karsten

2006-11-06T23:59:59.000Z

403

Steam-injection profile control using limited-entry perforations  

SciTech Connect

A completion technique for steam-injection wells that ensures improved profile distribution of steam into several independent sands is being used at the South Belridge field in California. Previously, steam profiles were poor for many of the conventionally perforated (two 3/8-in. (9.5-mm) -diameter holes per foot) injection wells. This standard completion does not guarantee that the thicker, higher-permeability sands will not act as thief zones with respect to the thinner, tighter sands open in the same wellbore. Limited-entry perforating (typically one hole per 15 to 20 ft (4.6 to 6.1m) of gross interval with at least one in each major sand member) provides the best assurance of achieving a uniform injection profile in single-wellbore multisand completions.

Small, G.P.

1986-09-01T23:59:59.000Z

404

Steam-injection profile control using limited-entry perforations  

Science Conference Proceedings (OSTI)

A completion technique for steam injection wells that assures improved profile distribution of steam into several independent sands is being used at the South Belridge Field, California. Previously, steam profiles were poor for many of the conventionally perforated (two-3/8'' diameter holes per foot) injection wells. This standard completion does not guarantee that the thicker, higher permeability sands will not act as thief zones with respect to the thinner, tighter sands open in the same wellbore. Limited entry perforating (typically one hole per 15-20' of gross interval with at least one in each major sand member) provides the best assurance of achieving a uniform injection profile in single wellbore multi-sand completions.

Small, G.P.

1985-03-01T23:59:59.000Z

405

test | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

test test test test More Documents & Publications Software Testing Checklist February2GuidanceMemorandum.pdf Site Transition Plan Guidance...

406

Interwell Connectivity and Diagnosis Using Correlation of Production and Injection Rate Data in Hydrocarbon Production  

Science Conference Proceedings (OSTI)

This report details progress on inferring interwell communication from well rate fluctuations. Starting with the procedure of Albertoni and Lake (2003) as a foundation, the goal of the project is to develop further procedures to infer reservoir properties through weights derived from correlations between injection and production rates. A modified method, described in Jensen et al. (2005) and Yousef et al. (2005), and herein referred to as the ''capacitance model'', produces two quantities, {lambda} and {tau}, for each injector-producer well pair. We have focused on the following items: (1) Approaches to integrate {lambda} and {tau} to improve connectivity evaluations. Interpretations have been developed using Lorenz-style and log-log plots to assess heterogeneity. Testing shows the interpretations can identify whether interwell connectivity is controlled by flow through fractures, high-permeability layers, or due to partial completion of wells. Applications to the South Wasson and North Buck Draw Fields show promising results. (2) Optimization of waterflood injection rates using the capacitance model and a power law relationship for watercut to maximize economic return. Initial tests using simulated data and a range of oil prices show the approach is working. (3) Spectral analysis of injection and production data to estimate interwell connectivity and to assess the effects of near-wellbore gas on the results. Development of methods and analysis are ongoing. (4) Investigation of methods to increase the robustness of the capacitance method. These methods include revising the solution method to simultaneously estimate {lambda} and {tau} for each well pair. This approach allows for further constraints to be imposed during the computation, such as limiting {tau} to a range of values defined by the sampling interval and duration of the field data. This work is proceeding. Further work on this project includes the following: (1) Refinement and testing of the waterflood optimization process, including optimization on more complex situations e.g., time effects on revenue and water injection and disposal costs. (2) Completion of the spectral-based analysis and determination of the effects of near-wellbore gas on the results. (3) Revision of the capacitance model procedures to provide more robust results which are insensitive to the initial estimates of {tau} needed in the nonlinear regression.

Jerry L. Jensen; Larry W. Lake; Ali Al-Yousef; Pablo Gentil; Nazli Demiroren

2005-05-31T23:59:59.000Z

407

Tracer Testing At Coso Geothermal Area (1993) | Open Energy Information  

Open Energy Info (EERE)

Tracer Testing At Coso Geothermal Area (1993) Tracer Testing At Coso Geothermal Area (1993) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Tracer Testing At Coso Geothermal Area (1993) Exploration Activity Details Location Coso Geothermal Area Exploration Technique Tracer Testing Activity Date 1993 Usefulness useful DOE-funding Unknown Exploration Basis To determine the steam and water mass flow rate Notes The method involves precisely metered injection of liquid and vapor phase tracers into the two-phase production pipeline and concurrent sampling of each phase downstream of the injection point. Subsequent chemical analysis of the steam and water samples for tracer content enables the calculation of mass flowrate for each phase given the known mass injection rates of

408

Human Collagen Injections to Reduce Rectal Dose During Radiotherapy  

Science Conference Proceedings (OSTI)

Objectives: The continuing search for interventions, which address the incidence and grade of rectal toxicities associated with radiation treatment of prostate cancer, is a major concern. We are reporting an investigational trial using human collagen to increase the distance between the prostate and anterior rectal wall, thereby decreasing the radiation dose to the rectum. Methods: This is a pilot study evaluating the use of human collagen as a displacing agent for the rectal wall injected before starting a course of intensity-modulated radiotherapy (IMRT) for prostate cancer. Using a transperineal approach, 20 mL of human collagen was injected into the perirectal space in an outpatient setting. Computerized IMRT plans were performed pre- and postcollagen injection, and after a patient completed their radiotherapy, to determine radiation dose reduction to the rectum associated with the collagen injection. Computed tomography scans were performed 6 months and 12 months after completing their radiotherapy to evaluate absorption rate of the collagen. All patients were treated with IMRT to a dose of 75.6 Gy to the prostate. Results: Eleven patients were enrolled into the study. The injection of human collagen in the outpatient setting was well tolerated. The mean separation between the prostate and anterior rectum was 12.7 mm. The mean reduction in dose to the anterior rectal wall was 50%. All men denied any rectal symptoms during the study. Conclusions: The transperineal injection of human collagen for the purpose of tissue displacement is well tolerated in the outpatient setting. The increased separation between the prostate and rectum resulted in a significant decrease in radiation dose to the rectum while receiving IMRT and was associated with no rectal toxicities.

Noyes, William R., E-mail: noyes@cancercenternd.com [Department of Radiation Oncology, Cancer Center of North Dakota, Grand Forks, ND (United States); Hosford, Charles C. [Department of Medical Statistics, University of North Dakota School of Medicine, Grand Forks, ND (United States); Schultz, Steven E. [Department of Urology, RiverView Health, Grand Forks, ND (United States)

2012-04-01T23:59:59.000Z

409

Interwell pressure testing for field pilots  

SciTech Connect

Procedures are described, and results are compared with core analyses, for a number of transient pressure experiments that were carried out between wells in a small chemical flood pilot. Tests include: a standard pulse test, a simultaneous pressure buildup and falloff of wells in a five-spot pattern, a reverse pulse test, in which response from a producer was measured at a nearby injector during injection, and production drawdown tests from normally shut-in observation wells during polymer injection and during subsequent waterflood in a nearby injector. Flowing these observation wells provided an effective way to measure in-situ mobilities of injected fluids. For pulse tests, a simplified method for design and interpretation of single pulses is derived from basic equations. Dimensionless functions, representing directional permeability and geometrical mean permeability, are shown to be functions of a single dimensionless time lag of the maximum pressure response. For large dimensionless time lags, the ratio of dimensionless permeabilities approaches the value ..pi..e and simple geometric relationships may be used to predict either compressibility or formation thickness.

Stegemeier, G.L.

1982-09-01T23:59:59.000Z

410

Planning and design of additional East Mesa Geothermal Test Facilities. Phase 1B. Volume II. Procurement package  

DOE Green Energy (OSTI)

Procurement packages of technical specifications and construction drawings for eleven test facility additions to the ERDA East Mesa Geothermal Component Test Facility are presented. Each of the specifications includes all of the technical requirements needed for procurement and construction starting with Division 2. The information is presented under the following subject headings: injection pump system: 52-2 injection pipeline; control and instrumentation spools; calibration test bench; test pad modifications; test pad piping headers; production and injection wells; well 5-2 modifications; well 8-1 down-hole pump; well 6-1 down-hole pump; and well 8-1 booster pump. (JGB)

Pearson, R.O.

1976-10-15T23:59:59.000Z

411

Negative ion-based neutral injection on DIII-D  

SciTech Connect

High energy negative ion-based neutral beam injection is a strong candidate for heating and non-inductive current drive in tokamaks. Many of the questions related to the physics and engineering of this technique remain unanswered. In this paper, we consider the possibility of negative ion-based neutral beam injection on DIII-D. We establish the desired parameter space by examining physics trades. This is combined with potential design constraints and a survey of component technology options to establish an injector concept. Injector performance is estimated assuming particular component technologies, and concept flexibility with respect to incorporating alternate technologies is described. 9 refs., 6 figs., 4 tabs.

Stewart, L.D.; Bhadra, D.K.; Colleraine, A.P.; Kim, J.

1990-01-01T23:59:59.000Z

412

Charge - dependent increase in coherence of synchrotron oscillation at injection  

SciTech Connect

Because of coupled bunch instability and/or because of some unidentified mechanism, bunches from the 8 GeV Booster accelerator at Fermilab arrive in the Main Injector synchrotron with a complicated centroid distribution in phase and energy. The currently installed broad band kicker provides a maximum of 2 kV, insufficient to remove injection errors before the oscillations would de-cohere, ignoring the influence of bunch charge. Perhaps surprisingly, for sufficient but generally modest charge, the effect of potential well distortion is to maintain bunch integrity. This talk illustrates the phenomenon for injection into the Fermilab Main Injector and offers an explanation sufficiently general to apply elsewhere.

MacLachlan, J.A.; /Fermilab

2004-11-01T23:59:59.000Z

413

Blue light emitting diode internal and injection efficiency  

Science Conference Proceedings (OSTI)

A simple experimental method of light emitting diode(LED) injection efficiency (IE) determination was suggested. IE and internal quantum efficiency(IQE) calculation is an actual and difficult problem in LED science. In this paper IE and IQE of blue LEDs were determined separately. The method is based on electroluminescence data fitting by the modified rate equation model. Efficiency droop caused by Auger recombination and poor injection were taken into account. Only one reasonable assumption was accepted during the calculations: IE tends to 1 at low current densities.

Ilya E. Titkov; Denis A. Sannikov; Young-Min Park; Joong-Kon Son

2012-01-01T23:59:59.000Z

414

High-resolution seismic studies applied to injected geothermal fluids  

DOE Green Energy (OSTI)

The application of high-resolution microseismicity studies to the problem of monitoring injected fluids is one component of the Geothermal Injection Monitoring Project at LLNL. The evaluation of microseismicity includes the development of field techniques, and the acquisition and processing of events during the initial development of a geothermal field. To achieve a specific detection threshold and location precision, design criteria are presented for seismic networks. An analysis of a small swarm near Mammoth Lakes, California, demonstrates these relationships and the usefulness of high-resolution seismic studies. A small network is currently monitoring the Mammoth-Pacific geothermal power plant at Casa Diablo as it begins production.

Smith, A.T.; Kasameyer, P.

1985-01-01T23:59:59.000Z

415

Effect of Temperature on NOx Reduction by Nitrogen Atom Injection  

DOE Green Energy (OSTI)

Chemical reduction of NO{sub x} can be accomplished by injection of nitrogen atoms into the diesel engine exhaust stream. The nitrogen atoms can be generated from a separate stream of pure N{sub 2} by means of plasma jets or non-thermal plasma reactors. This paper examines the effect of exhaust temperature on the NO{sub x} reduction efficiency that can be achieved by nitrogen atom injection. It is shown that to achieve a high NO{sub x} reduction efficiency at a reasonable power consumption penalty, the exhaust temperature needs to be 100 C or less.

Penetrante, B

1999-10-28T23:59:59.000Z

416

Boiling Water Reactor (BWR) Zinc Injection Strategy Evaluation  

Science Conference Proceedings (OSTI)

All U.S. boiling water reactors (BWRs) inject depleted zinc oxide (DZO) into the reactor feedwater for the purpose of suppressing drywell shutdown radiation dose rates. Current guidance in BWRVIP-190: BWR Vessel and Internals Project, BWR Water Chemistry Guidelines2008 Revision (EPRI report 1016579) is to inject sufficient zinc to achieve a Co-60(s)/Zn(s) ratio of Utility-specific goals may encourage even lower Co-60(s)/Zn(s) levels. This may be in part because BWR e...

2010-11-24T23:59:59.000Z

417

Test plan  

U.S. Energy Information Administration (EIA)

3.0 TEST PLAN METHODOLOGY 8. 3.1 Assumptions 8. 3.2 Methodology 8. 4.0 COMMENTS ON INITIAL VIEW OF THE DATA 16 1.0 INTRODUCTION. EIA tasked Allied ...

418

Optimization of beam injection into the first accelerating module at TTF with cavity dipole mode signals  

E-Print Network (OSTI)

Optimization of beam injection into the first accelerating module at TTF with cavity dipole mode signals

Baboi, N; Kreps, G; McCormick, D; Napoly, O; Paparella, R G; Ross, M; Schlarb, H; Smith, T; Wendt, M

2005-01-01T23:59:59.000Z

419

The application of high frequency seismic monitoring methods for the mapping of fluid injections  

DOE Green Energy (OSTI)

This paper describes experimental work using seismic methods for monitoring the path of fluid injections. The most obvious application is the high pressure fluid injections for the purpose of hydrofracturing. Other applications are the injection of grout into shallow subsurface structures and the disposal of fluids in the geothermal and toxic waste industries. In this paper hydrofracture monitoring and grout injections will be discussed.

Majer, E.L.

1987-04-01T23:59:59.000Z

420

Design considerations for a steam-injection pilot with in-situ foaming  

Science Conference Proceedings (OSTI)

This report reviews the necessary aspects of the planning, operation, evaluation, environmental impact and cost to implement a field pilot of steam injection with in-situ foaming. The Stanford University Petroleum Research Institute (SUPRI) is planning to implement such a pilot in Kern County, California. The cost of the pilot will be shared by the US Department of Energy and an oil company. Some important aspects of drilling and completion programs and their specifications, permits from regulatory bodies, and downhole tools to improve steam stimulation are discussed. The essential surface facilities which include water treatment plant, steam generator, demulsifier and dehydrator are considered. The necessary laboratory research in support of the pilot has been recommended. The formation evaluation and reservoir engineering effort for the pilot has been divided into three phases: reservoir definition, reservoir monitoring and post-pilot study. Appropriate techniques applicable to each phase of the test have been discussed. The environmental impact regulations as related to the steam injection process have been considered. In particular, the environmental problems associated with the burning of crude oil and desulfurization of flue gas have been discussed. Other environmental considerations such as solid and liquid waste disposal, health and safety are also discussed. An estimate of the cost of this field test is presented. Three scenarii (for pilots with high, medium, and low investment potentials, respectively) are presented. Since this report was prepared, a specific site for the supri pilot has been chosen. Appendices G and H present the details on this site.

Siddiqui, M.H.; Sanyal, S.K.; Horn, A.J.

1982-08-01T23:59:59.000Z

Note: This page contains sample records for the topic "insar injectivity test" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Ultra Bright LED Light Injection Calibration System for MINOS  

E-Print Network (OSTI)

We describe here a proposal for a light injection calibration system for the MINOS detectors based on ultra bright blue LEDs as the light source. We have shown that these LEDs are bright enough to span over two orders of magnitude in light intensity, commensurate with that expected in a single scintillator strip in the MINOS neutrino detectors.

Anderson, B; Dervan, P J; Lauber, J A; Thomas, J

1999-01-01T23:59:59.000Z

422

Overview of Recent Developments in Pellet Injection for ITER  

Science Conference Proceedings (OSTI)

Pellet injection is the primary fueling technique planned for core fueling of ITER burning plasmas. Also, the injection of relatively small pellets to purposely trigger rapid small edge localized modes (ELMs) has been proposed as a possible solution to the heat flux damage from larger natural ELMs likely to be an issue on the ITER divertor surfaces. The ITER pellet injection system is designed to inject pellets into the plasma through both inner and outer wall guide tubes. The inner wall guide tubes will provide high throughput pellet fueling while the outerwall guide tubes will be used primarily to trigger ELMs at a high frequency (>15 Hz). The pellet fueling rate ofeach injector is to be up to 120 Pa-m3/s, which will require the formation of solid D-T at a volumetric rate of ~1500 mm3/s. Two injectors are to be provided for ITER at the startup with a provision for up to six injectorsduring the D-T phase. The required throughput of each injector is greater than that of any injector built to date, and a novel twin-screw continuous extrusion system is being developed to meet the challenging design parameters. Status of the development activities will be presented, highlighting recent progress.

Combs, Stephen Kirk [ORNL; Baylor, Larry R [ORNL; Meitner, Steven J [ORNL; Caughman, John B [ORNL; Rasmussen, David A [ORNL; Maruyama, So [ITER Organization, Cadarache, France

2012-01-01T23:59:59.000Z

423

Diffusion of a plasma subject to neutral beam injection  

SciTech Connect

Two-dimensional numerical plasma simulations have been carried out in a uniform magnetic field to study the effects of neutral beam injection on plasma diffusion. Neutral beams injected across a magnetic field are assumed to be ionized by various ionization processes in a plasma. It is found that the suprathermal convective motion of a plasma generated by the injection of neutral beams is dissipated via anomalous viscosity, leading to enhanced cross-field diffusion. The diffusion coefficient depends weakly on the magnetic field and plasma density, similar to the diffusion due to thermally excited convective cells. The magnitude of the diffusion increases with the injection energy and is much larger than the thermal diffusion because of the presence of suprathermal plasma convection. It is shown that a similar anomalous plasma diffusion may occur in a plasma subject to radio frequency (RF) wave heating where only a localized region of plasma across a magnetic field is heated to a temperature much higher than the surrounding temperature. Theoretical investigations are given on the scaling of enhanced plasma diffusion.

Okuda, H.; Hiroe, S.

1986-10-01T23:59:59.000Z

424

Flow monitoring and control system for injection wells  

DOE Patents (OSTI)

The present invention relates to a system for monitoring and controlling the rate of fluid flow from an injection well used for in-situ remediation of contaminated groundwater. The United States Government has rights in this invention pursuant to Contract No. DE-AC09-89SR18035 between the US Department of Energy and Westinghouse Savannah River Company.

Corey, J.C.

1991-01-01T23:59:59.000Z

425

Optical Diagnostics and Direct Injection of Liquid Fuel Sprays  

Science Conference Proceedings (OSTI)

The research described here addresses the problem of a paucity of high quality data on the full field structure of high pressure liquid fuel sprays for gasoline direct injection, GDI, engines. The paper describes the application of phase Doppler anemometry, ... Keywords: GDI, PDA, laser sheet, spray, visualisation

G. K. Hargrave; G. Wigley; J. Allen; A. Bacon

1999-12-01T23:59:59.000Z

426

Highly efficient 6-stroke engine cycle with water injection  

Science Conference Proceedings (OSTI)

A six-stroke engine cycle having improved efficiency. Heat is recovered from the engine combustion gases by using a 6-stroke engine cycle in which combustion gases are partially vented proximate the bottom-dead-center position of the fourth stroke cycle, and water is injected proximate the top-dead-center position of the fourth stroke cycle.

Szybist, James P; Conklin, James C

2012-10-23T23:59:59.000Z

427

Influence of spectral width on power fluctuations of injection lasers  

SciTech Connect

An experimental investigation was made of the noise of AlGaAs injection lasers in the 10--100 MHz frequency range. It was found that under steady-state conditions the fluctuation level is governed by the width of the laser emission spectrum.

Bessonov, Y.L.; Kurlenkov, S.S.; Morozov, V.N.; Sapozhnikov, S.M.; Thai, C.t.; Shidlovskii, V.P.

1985-02-01T23:59:59.000Z

428

Flow monitoring and control system for injection wells  

DOE Patents (OSTI)

A system for monitoring and controlling the injection rate of fluid by an injection well of an in-situ remediation system for treating a contaminated groundwater plume. The well is fitted with a gated insert, substantially coaxial with the injection well. A plurality of openings, some or all of which are equipped with fluid flow sensors and gates, are spaced along the insert. The gates and sensors are connected to a surface controller. The insert may extend throughout part of, or substantially the entire length of the injection well. Alternatively, the insert may comprise one or more movable modules which can be positioned wherever desired along the well. The gates are opened part-way at the start of treatment. The sensors monitor and display the flow rate of fluid passing through each opening on a controller. As treatment continues, the gates are opened to increase flow in regions of lesser flow, and closed to decrease flow in regions of greater flow, thereby approximately equalizing the amount of fluid reaching each part of the plume.

Corey, John C. (212 Lakeside Dr., Aiken, SC 29803)

1993-01-01T23:59:59.000Z

429

Flow monitoring and control system for injection wells  

DOE Patents (OSTI)

A system for monitoring and controlling the injection rate of fluid by an injection well of an in-situ remediation system for treating a contaminated groundwater plume. The well is fitted with a gated insert, substantially coaxial with the injection well. A plurality of openings, some or all of which are equipped with fluid flow sensors and gates, are spaced along the insert. The gates and sensors are connected to a surface controller. The insert may extend throughout part of, or substantially the entire length of the injection well. Alternatively, the insert may comprise one or more movable modules which can be positioned wherever desired along the well. The gates are opened part-way at the start of treatment. The sensors monitor and display the flow rate of fluid passing through each opening on a controller. As treatment continues, the gates are opened to increase flow in regions of lesser flow, and closed to decrease flow in regions of greater flow, thereby approximately equalizing the amount of fluid reaching each part of the plume.

Corey, J.C.

1993-02-16T23:59:59.000Z

430

Applications of geochemistry to problems in geothermal injection  

DOE Green Energy (OSTI)

Conventional reservoir engineering studies have, in the past, dealt mainly with interpretation of pressure transient effects in a reservoir. Present-day techniques can be used in many reservoirs to forecast with some reliability the probability, magnitude and timing of pressure interference among wells. However, forecasting fluid breakthrough from an injection well to a production well in geologically complex geothermal reservoirs is not presently possible with any reliability, and forecasting thermal breakthrough is even more difficult. In addition, the chemical effects of injection are poorly understood at present, and it is not possible to predict beforehand the full range of scaling and aquifer plugging problems that may be encountered. This report discusses development of chemical tracers specifically designed for geothermal applications so that breakthrough of injectate can be detected early, and field and laboratory studies on the chemical interactions among reservoir fluids, reservoir rocks and injected fluids so that these interactions can be quantified and models developed for predicting any degradation (or enhancement) of permeability.

Wright, P.M.

1985-02-01T23:59:59.000Z

431

Cerro Prieto cold water injection: effects on nearby production wells  

DOE Green Energy (OSTI)

The liquid-dominated Cerro Prieto geothermal field of northern Baja California, Mexico has been under commercial exploitation since 1973. During the early years of operation, all waste brines were sent to an evaporation pond built west of the production area. In 1989, cooled pond brines began to be successfully injected into the reservoir along the western boundary of the geothermal system. The injection rate varied over the years, and is at present about 20% of the total fluid extracted. As expected under the continental desert conditions prevailing in the area, the temperature and salinity of the pond brines change with the seasons, being higher during the summer and lower during the winter. The chemistry of pond brines is also affected by precipitation of silica, oxidation of H{sub 2}S and reaction with airborne clays. Several production wells in the western part of the field (CP-I area) showed beneficial effects from injection. The chemical (chloride, isotopic) and physical (enthalpy, flow rate) changes observed in producers close to the injectors are reviewed. Some wells showed steam flow increases, in others steam flow decline rates flattened. Because of their higher density, injected brines migrated downward in the reservoir and showed up in deep wells.

Truesdell, A.H.; Lippmann, M.J.; De Leon, J.; Rodriguez, M.H.

1999-07-01T23:59:59.000Z

432

DISRUPTION MITIGATION WITH HIGH-PRESSURE NOBLE GAS INJECTION  

Science Conference Proceedings (OSTI)

OAK A271 DISRUPTION MITIGATION WITH HIGH-PRESSURE NOBLE GAS INJECTION. High-pressure gas jets of neon and argon are used to mitigate the three principal damaging effects of tokamak disruptions: thermal loading of the divertor surfaces, vessel stress from poloidal halo currents and the buildup and loss of relativistic electrons to the wall. The gas jet penetrates as a neutral species through to the central plasma at its sonic velocity. The injected gas atoms increase up to 500 times the total electron inventory in the plasma volume, resulting in a relatively benign radiative dissipation of >95% of the plasma stored energy. The rapid cooling and the slow movement of the plasma to the wall reduce poloidal halo currents during the current decay. The thermally collapsed plasma is very cold ({approx} 1-2 eV) and the impurity charge distribution can include > 50% fraction neutral species. If a sufficient quantity of gas is injected, the neutrals inhibit runaway electrons. A physical model of radiative cooling is developed and validated against DIII-D experiments. The model shows that gas jet mitigation, including runaway suppression, extrapolates favorably to burning plasmas where disruption damage will be more severe. Initial results of real-time disruption detection triggering gas jet injection for mitigation are shown.

WHYTE, DG; JERNIGAN, TC; HUMPHREYS, DA; HYATT, AW; LASNIER, CJ; PARKS, PB; EVANS, TE; TAYLOR, PL; KELLMAN, AG; GRAY, DS; HOLLMANN, EM

2002-10-01T23:59:59.000Z

433

Development of Improved Oil Field Waste Injection Disposal Techniques  

Science Conference Proceedings (OSTI)

The goals of this project have was to: (1) assemble and analyze a comprehensive database of past waste injection operations; (2) develop improved diagnostic techniques for monitoring fracture growth and formation changes; (3) develop operating guidelines to optimize daily operations and ultimate storage capacity of the target formation; and (4) to apply these improved models and guidelines in the field.

Terralog Technologies

2002-11-25T23:59:59.000Z

434

NOx reduction by electron beam-produced nitrogen atom injection  

DOE Patents (OSTI)

Deactivated atomic nitrogen generated by an electron beam from a gas stream containing more than 99% N.sub.2 is injected at low temperatures into an engine exhaust to reduce NOx emissions. High NOx reduction efficiency is achieved with compact electron beam devices without use of a catalyst.

Penetrante, Bernardino M. (San Ramon, CA)

2002-01-01T23:59:59.000Z

435

POROSITY AND PERMEABILITY EVOLUTION ACCOMPANYING HOT FLUID INJECTION  

E-Print Network (OSTI)

. Additionally, funding was provided by the SUPRI-A Industrial Affiliates and the President's Fund of Stanford to the setup used by Koh et al. (1996), but it allows for measurement of porosity by CT scanning. A Blue-M oven to the oven set- point temperature. System pressure is elevated by a back-pressure regulator and injection

436

Ultra Bright LED Light Injection Calibration System for MINOS  

E-Print Network (OSTI)

We describe here a proposal for a light injection calibration system for the MINOS detectors based on ultra bright blue LEDs as the light source. We have shown that these LEDs are bright enough to span over two orders of magnitude in light intensity, commensurate with that expected in a single scintillator strip in the MINOS neutrino detectors.

B. Anderson; A. Anjomshoaa; P. Dervan; J. A. Lauber; J. Thomas

1998-10-26T23:59:59.000Z

437

Ultra Bright LED Light Injection Calibration System for MINOS  

E-Print Network (OSTI)

We describe here a proposal for a light injection calibration system for the MINOS detectors based on ultra bright blue LEDs as the light source. We have shown that these LEDs are bright enough to span over two orders of magnitude in light intensity, commensurate with that expected in a single scintillator strip in the MINOS neutrino detectors. 1

B. Anderson; A. Anjomshoaa; P. Dervan; J. A. Lauber; J. Thomas

2008-01-01T23:59:59.000Z

438

Monte Carlo simulation of neutral beam injection into fusion reactors  

SciTech Connect

Motivations and techniques for the Monte Carlo computer simulation of energetic neutral beam injection for fusion reactors are described. The versatility of this approach allows a significantly more sophisticated treatment of charge transfer collision phenomena and consequent effects on engineering design than available from prior work. Exemplary results for a mirror Fusion Engineering Research Facility (FERF) are discussed. (auth)

Miller, R.L.

1975-09-15T23:59:59.000Z

439

Injection/withdrawal scheduling for natural gas storage facilities  

Science Conference Proceedings (OSTI)

Control decisions for gas storage facilities are made in the face of extreme uncertainty over future natural gas prices on world markets. We examine the problem faced by owners of storage contracts of how to manage the injection/withdrawal schedule of ... Keywords: natural gas storage, optimization, scheduling

Alan Holland

2007-03-01T23:59:59.000Z

440

Reservoir response to injection in the Southeast Geysers  

DOE Green Energy (OSTI)

A 20 megawatt (MW) increase in steam flow potential resulted within five months of the start-up of new injection wells in the Southeast Geysers. Flow rate increases were observed in 25 wells offset to the injectors, C-11 and 956A-1. This increased flowrate was sustained during nine months of continuous injection with no measurable decrease in offset well temperature until C-11 was shut-in due to wellbore bridging. The responding steam wells are located in an area of reduced reservoir steam pressure known as the Low Pressure Area (LPA). The cause of the flowrate increases was twofold (1) an increase in static reservoir pressure and (2) a decrease in interwell communication. Thermodynamic and microseismic evidence suggests that most of the water is boiling near the injector and migrating to offset wells located ''down'' the static pressure gradient. However, wells showing the largest increase in steam flowrate are not located at the heart of the pressure sink. This indicates that localized fracture distribution controls the preferred path of fluid migration from the injection well. A decrease in non-condensible gas concentrations was also observed in certain wells producing injection derived steam within the LPA. The LPA project has proven that steam suppliers can work together and benefit economically from joint efforts with the goal of optimizing the use of heat from The Geysers reservoir. The sharing of costs and information led directly to the success of the project and introduces a new era of increased cooperation at The Geysers.

Enedy, Steve; Enedy, Kathy; Maney, John

1991-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "insar injectivity test" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Lower 48 States Total Natural Gas Injections into Underground Storage  

U.S. Energy Information Administration (EIA) Indexed Site

Total Natural Gas Injections into Underground Storage (Million Cubic Feet) Total Natural Gas Injections into Underground Storage (Million Cubic Feet) Lower 48 States Total Natural Gas Injections into Underground Storage (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 2011 50,130 81,827 167,632 312,290 457,725 420,644 359,267 370,180 453,548 436,748 221,389 90,432 2012 74,854 56,243 240,351 263,896 357,965 323,026 263,910 299,798 357,109 327,767 155,554 104,953 2013 70,592 41,680 99,330 270,106 465,787 438,931 372,458 370,471 418,848 - = No Data Reported; -- = Not Applicable; NA = Not Available; W = Withheld to avoid disclosure of individual company data. Release Date: 12/12/2013 Next Release Date: 1/7/2014 Referring Pages: Injections of Natural Gas into Underground Storage - All Operators

442

Compendium of regulatory requirements governing underground injection of drilling waste.  

Science Conference Proceedings (OSTI)

Large quantities of waste are produced when oil and gas wells are drilled. The two primary types of drilling wastes include used drilling fluids (commonly referred to as muds), which serve a variety of functions when wells are drilled, and drill cuttings (rock particles ground up by the drill bit). Some oil-based and synthetic-based muds are recycled; other such muds, however, and nearly all water-based muds, are disposed of. Numerous methods are employed to manage drilling wastes, including burial of drilling pit contents, land spreading, thermal processes, bioremediation, treatment and reuse, and several types of injection processes. This report provides a comprehensive compendium of the regulatory requirements governing the injection processes used for disposing of drilling wastes; in particular, for a process referred to in this report as slurry injection. The report consists of a narrative discussion of the regulatory requirements and practices for each of the oil- and gas-producing states, a table summarizing the types of injection processes authorized in each state, and an appendix that contains the text of many of the relevant state regulations and policies. The