Sample records for input voltage 208vac

  1. Operation of buck regulator with ultra-low input voltage

    E-Print Network [OSTI]

    Harris, Cory Angelo

    2014-01-01T23:59:59.000Z

    Based on the LTC3621 and LTC3624, the designed buck regulator proposed in this thesis aims to lower the allowed input voltage and increase efficiency compared to the original part without making significant changes to ...

  2. Biased low differential input impedance current receiver/converter device and method for low noise readout from voltage-controlled detectors

    DOE Patents [OSTI]

    Degtiarenko, Pavel V. (Williamsburg, VA); Popov, Vladimir E. (Newport News, VA)

    2011-03-22T23:59:59.000Z

    A first stage electronic system for receiving charge or current from voltage-controlled sensors or detectors that includes a low input impedance current receiver/converter device (for example, a transimpedance amplifier), which is directly coupled to the sensor output, a source of bias voltage, and the device's power supply (or supplies), which use the biased voltage point as a baseline.

  3. Analysis and design of six and twelve pulse diode rectifier systems under voltage unbalance/distortion and some new methods to reduce input current harmonics

    E-Print Network [OSTI]

    Rendusara, Dudi Abdullah

    1995-01-01T23:59:59.000Z

    ANALYSIS AND DESIGN OF SIX AND TWELVE PULSE DIODE RECTIFIER SYSTEMS UNDER VOLTAGE UNBALANCE/DISTORTION AND SOME NEW METHODS TO REDUCE INPUT CURRENT HARMONICS A Thesis by DUDI ABDULLAH RENDUSARA Submitted to the Office of Graduate Studies.../DISTORTION AND SOME NEW METHODS TO REDUCE INPUT CURRENT HARMONICS A Thesis by DUDI ABDULLAH RENDUSARA Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE Approved...

  4. Impact of Input Voltage Sag and Unbalance on DC Link Inductor and Capacitor Stress in Adjustable Speed Drives

    E-Print Network [OSTI]

    Lipo, Thomas

    , outages, voltage surges and sags. Power quality problems induced in adjustable-speed drives (ASDs) have (120 Hz for 60 Hz system) that increases the electrical stresses on the dc bus choke inductor (if used

  5. Abstract--Voltage and current measurements are routinely used as inputs to transducers in order to obtain sensory information

    E-Print Network [OSTI]

    estimators [1] and for general energy management systems. II. NON-COLLOCATED VOLTAGE AND CURRENT MEASUREMENTS River Project (SRP), Phoenix, AZ. Authors Mann and Heydt are with the Department of Electrical Engineer, complex power measurement. I. INTRODUCTION OWER system measurements may possess error due to inherent

  6. Voltage balanced multilevel voltage source converter system

    DOE Patents [OSTI]

    Peng, F.Z.; Lai, J.S.

    1997-07-01T23:59:59.000Z

    Disclosed is a voltage balanced multilevel converter for high power AC applications such as adjustable speed motor drives and back-to-back DC intertie of adjacent power systems. This converter provides a multilevel rectifier, a multilevel inverter, and a DC link between the rectifier and the inverter allowing voltage balancing between each of the voltage levels within the multilevel converter. The rectifier is equipped with at least one phase leg and a source input node for each of the phases. The rectifier is further equipped with a plurality of rectifier DC output nodes. The inverter is equipped with at least one phase leg and a load output node for each of the phases. The inverter is further equipped with a plurality of inverter DC input nodes. The DC link is equipped with a plurality of rectifier charging means and a plurality of inverter discharging means. The plurality of rectifier charging means are connected in series with one of the rectifier charging means disposed between and connected in an operable relationship with each adjacent pair of rectifier DC output nodes. The plurality of inverter discharging means are connected in series with one of the inverter discharging means disposed between and connected in an operable relationship with each adjacent pair of inverter DC input nodes. Each of said rectifier DC output nodes are individually electrically connected to the respective inverter DC input nodes. By this means, each of the rectifier DC output nodes and each of the inverter DC input nodes are voltage balanced by the respective charging and discharging of the rectifier charging means and the inverter discharging means. 15 figs.

  7. Electro-optic high voltage sensor

    DOE Patents [OSTI]

    Davidson, James R.; Seifert, Gary D.

    2003-09-16T23:59:59.000Z

    A small sized electro-optic voltage sensor capable of accurate measurement of high voltages without contact with a conductor or voltage source is provided. When placed in the presence of an electric field, the sensor receives an input beam of electromagnetic radiation. A polarization beam displacer separates the input beam into two beams with orthogonal linear polarizations and causes one linearly polarized beam to impinge a crystal at a desired angle independent of temperature. The Pockels effect elliptically polarizes the beam as it travels through the crystal. A reflector redirects the beam back through the crystal and the beam displacer. On the return path, the polarization beam displacer separates the elliptically polarized beam into two output beams of orthogonal linear polarization. The system may include a detector for converting the output beams into electrical signals and a signal processor for determining the voltage based on an analysis of the output beams.

  8. Current Sourcing ZCS Magnetron Driver for Low Input Voltage Applications

    E-Print Network [OSTI]

    to the parasitics, increasing EMI emission and power loss. Another drawback is the fact that these converters are turned off under extremely high currents which again increases EMI emission and power loss. Other

  9. Coupled Dual Interleaved Flyback Converter for High Input Voltage Application

    E-Print Network [OSTI]

    Lehman, Brad

    components, including transformers and inductors, significantly influences the overall profiles magnetic core to store the energy in the power transformer. A Flyback converter is a popular choice for low. All the center and outer legs are gapped, and the transformers are integrated into one magnetic core

  10. TART input manual

    SciTech Connect (OSTI)

    Kimlinger, J.R.; Plechaty, E.F.

    1982-04-01T23:59:59.000Z

    The TART code is a Monte Carlo neutron/photon transport code that is only on the CRAY computer. All the input cards for the TART code are listed, and definitions for all input parameters are given. The execution and limitations of the code are described, and input for two sample problems are given. (WHK)

  11. High Voltage Safety Act

    Broader source: Energy.gov [DOE]

    The purpose of the High Voltage Safety Act is to prevent injury to persons and property and interruptions of utility service resulting from accidental or inadvertent contact with high-voltage...

  12. Automatic voltage imbalance detector

    DOE Patents [OSTI]

    Bobbett, Ronald E. (Los Alamos, NM); McCormick, J. Byron (Los Alamos, NM); Kerwin, William J. (Tucson, AZ)

    1984-01-01T23:59:59.000Z

    A device for indicating and preventing damage to voltage cells such as galvanic cells and fuel cells connected in series by detecting sequential voltages and comparing these voltages to adjacent voltage cells. The device is implemented by using operational amplifiers and switching circuitry is provided by transistors. The device can be utilized in battery powered electric vehicles to prevent galvanic cell damage and also in series connected fuel cells to prevent fuel cell damage.

  13. Electro-optic high voltage sensor

    DOE Patents [OSTI]

    Davidson, James R. (Idaho Falls, ID); Seifert, Gary D. (Idaho Falls, ID)

    2002-01-01T23:59:59.000Z

    A small sized electro-optic voltage sensor capable of accurate measurement of high levels of voltages without contact with a conductor or voltage source is provided. When placed in the presence of an electric field, the sensor receives an input beam of electromagnetic radiation into the sensor. A polarization beam displacer serves as a filter to separate the input beam into two beams with orthogonal linear polarizations. The beam displacer is oriented in such a way as to rotate the linearly polarized beams such that they enter a Pockels crystal having at a preferred angle of 45 degrees. The beam displacer is therefore capable of causing a linearly polarized beam to impinge a crystal at a desired angle independent of temperature. The Pockels electro-optic effect induces a differential phase shift on the major and minor axes of the input beam as it travels through the Pockels crystal, which causes the input beam to be elliptically polarized. A reflecting prism redirects the beam back through the crystal and the beam displacer. On the return path, the polarization beam displacer separates the elliptically polarized beam into two output beams of orthogonal linear polarization representing the major and minor axes. The system may include a detector for converting the output beams into electrical signals, and a signal processor for determining the voltage based on an analysis of the output beams. The output beams are amplitude modulated by the frequency of the electric field and the amplitude of the output beams is proportional to the magnitude of the electric field, which is related to the voltage being measured.

  14. Meats & Products Agricultural Inputs

    E-Print Network [OSTI]

    Collett Jr., Jeffrey L.

    Meats & Products Agricultural Inputs Processing Idaho B20 C C B Meats and Livestock Products Index to agriculture? Legend Overall weighted grade Weighted rank Northwest Midwest Southwest East Meats & ProductsProcessingessing Maine B11 B A A Meats & Products Agricultural Inputs Processing New York F49 F F F soductsoducts

  15. The design of an A-C voltage regulator using a Wein Bridge detector

    E-Print Network [OSTI]

    Brown, Richard True

    1959-01-01T23:59:59.000Z

    ) the regulator would correct for changes in input voltage only, as the detector ie on the input side of the controller. In Figures 1(c) and 1(d) the xegulator would corxect fox' changes in input or load conditions as the detector is placed directly across... the load. Em D Figure 1; Four types of regulator connections. The connections shown in Figures 1(b) and l(d) are limited in that the output is usually less than the input voltage, whereas in Figures 1(a) and 1(c) the controller voltage can buck...

  16. Optical voltage reference

    DOE Patents [OSTI]

    Rankin, R.; Kotter, D.

    1994-04-26T23:59:59.000Z

    An optical voltage reference for providing an alternative to a battery source is described. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function. 2 figures.

  17. Voltage Control Technical Conference

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Intro Voltage Control Conference - BPA Active Power Control in Wind Parks - Siemens Interconnection Criteria for Frequency Response Requirements - NERC Model Validation...

  18. SRS Interface Input

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Interface Input 1. MOA's: The contractor has no MOA's in effect at the Tritium Operations (SRTO) level. 2. AIP's: The contractor has no AIP's in effect at the SRTO level. 3....

  19. Voltage verification unit

    DOE Patents [OSTI]

    Martin, Edward J. (Virginia Beach, VA)

    2008-01-15T23:59:59.000Z

    A voltage verification unit and method for determining the absence of potentially dangerous potentials within a power supply enclosure without Mode 2 work is disclosed. With this device and method, a qualified worker, following a relatively simple protocol that involves a function test (hot, cold, hot) of the voltage verification unit before Lock Out/Tag Out and, and once the Lock Out/Tag Out is completed, testing or "trying" by simply reading a display on the voltage verification unit can be accomplished without exposure of the operator to the interior of the voltage supply enclosure. According to a preferred embodiment, the voltage verification unit includes test leads to allow diagnostics with other meters, without the necessity of accessing potentially dangerous bus bars or the like.

  20. High voltage DC power supply

    DOE Patents [OSTI]

    Droege, Thomas F. (Batavia, IL)

    1989-01-01T23:59:59.000Z

    A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively.

  1. High voltage DC power supply

    DOE Patents [OSTI]

    Droege, T.F.

    1989-12-19T23:59:59.000Z

    A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively. 7 figs.

  2. High voltage electrical amplifier having a short rise time

    DOE Patents [OSTI]

    Christie, David J. (Pleasanton, CA); Dallum, Gregory E. (Livermore, CA)

    1991-01-01T23:59:59.000Z

    A circuit, comprising an amplifier and a transformer is disclosed that produces a high power pulse having a fast response time, and that responds to a digital control signal applied through a digital-to-analog converter. The present invention is suitable for driving a component such as an electro-optic modulator with a voltage in the kilovolt range. The circuit is stable at high frequencies and during pulse transients, and its impedance matching circuit matches the load impedance with the output impedance. The preferred embodiment comprises an input stage compatible with high-speed semiconductor components for amplifying the voltage of the input control signal, a buffer for isolating the input stage from the output stage; and a plurality of current amplifiers connected to the buffer. Each current amplifier is connected to a field effect transistor (FET), which switches a high voltage power supply to a transformer which then provides an output terminal for driving a load. The transformer comprises a plurality of transmission lines connected to the FETs and the load. The transformer changes the impedance and voltage of the output. The preferred embodiment also comprises a low voltage power supply for biasing the FETs at or near an operational voltage.

  3. Membrane potential and spike train statistics depend distinctly on input statistics Robert Rosenbaum1

    E-Print Network [OSTI]

    Azevedo, Ricardo

    - niques such as voltage sensitive dyes and local field po- tentials capture a mixture of subthreshold are most sensitive to modula- tions of a cell's input current when excitation is strong and firing rates. For example, the correlation between two signals obtained from voltage sensitive dyes or local field

  4. ABBGroup-1-High voltage lab

    E-Print Network [OSTI]

    Basse, Nils Plesner

    oscillations are due to travelling waves in the heating volume. #12;©ABBGroup-9- 3-Sep-07 2. High voltage phase interrupts the injected current, it is stressed by the transient recovery voltage (TRV) oscillating©ABBGroup-1- 3-Sep-07 High voltage lab Research on high voltage gas circuit breakers Nils P. Basse

  5. Electron launching voltage monitor

    DOE Patents [OSTI]

    Mendel, C.W.; Savage, M.E.

    1992-03-17T23:59:59.000Z

    An electron launching voltage monitor measures MITL voltage using a relationship between anode electric field and electron current launched from a cathode-mounted perturbation. An electron launching probe extends through and is spaced from the edge of an opening in a first MITL conductor, one end of the launching probe being in the gap between the MITL conductor, the other end being adjacent a first side of the first conductor away from the second conductor. A housing surrounds the launching probe and electrically connects the first side of the first conductor to the other end of the launching probe. A detector detects the current passing through the housing to the launching probe, the detected current being representative of the voltage between the conductors. 5 figs.

  6. Threshold voltage extraction circuit

    E-Print Network [OSTI]

    Hoon, Siew Kuok

    2000-01-01T23:59:59.000Z

    to that of the saturation method. However, instead of fixing Vos ? Vos, the drain current is measured as a function of Vos while Vns is fixed at a constant low voltage of 100mV to ensure operation in the linear MOSFET region. Neglecting channel length modulation effect... transistors are layout next to the DUT of the NMOS and PMOS Vr extraction circuits respectively for extraction of Vr via graphical means. GRAPHICAL METHOD OF THE THRESHOLD-VOLTAGE MEASUREMENT Using the graphical method, the characteristics of 4n versus Vos...

  7. Gen Inputs Settlement

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville Power AdministrationField8,Dist.Newof EnergyFunding OpportunityF2015Gen-Inputs-Settlement Sign

  8. An ultra-low voltage high gain operational transconductance amplifier for biomedical

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    An ultra-low voltage high gain operational transconductance amplifier for biomedical applications that work at ultra low voltage power supply. Moreover, low power dissipation is essential in these systems dissipation is also proposed in [5]. Differential pairs are commonly used as input stages, in an ultra-low

  9. Systems and methods for process and user driven dynamic voltage and frequency scaling

    DOE Patents [OSTI]

    Mallik, Arindam (Evanston, IL); Lin, Bin (Hillsboro, OR); Memik, Gokhan (Evanston, IL); Dinda, Peter (Evanston, IL); Dick, Robert (Evanston, IL)

    2011-03-22T23:59:59.000Z

    Certain embodiments of the present invention provide a method for power management including determining at least one of an operating frequency and an operating voltage for a processor and configuring the processor based on the determined at least one of the operating frequency and the operating voltage. The operating frequency is determined based at least in part on direct user input. The operating voltage is determined based at least in part on an individual profile for processor.

  10. E-beam high voltage switching power supply

    DOE Patents [OSTI]

    Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

    1997-01-01T23:59:59.000Z

    A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360.degree./n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load.

  11. E-beam high voltage switching power supply

    DOE Patents [OSTI]

    Shimer, D.W.; Lange, A.C.

    1997-03-11T23:59:59.000Z

    A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360{degree}/n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load. 7 figs.

  12. High voltage pulse conditioning

    DOE Patents [OSTI]

    Springfield, Ray M. (Sante Fe, NM); Wheat, Jr., Robert M. (Los Alamos, NM)

    1990-01-01T23:59:59.000Z

    Apparatus for conditioning high voltage pulses from particle accelerators in order to shorten the rise times of the pulses. Flashover switches in the cathode stalk of the transmission line hold off conduction for a determinable period of time, reflecting the early portion of the pulses. Diodes upstream of the switches divert energy into the magnetic and electrostatic storage of the capacitance and inductance inherent to the transmission line until the switches close.

  13. Charge-pump voltage converter

    DOE Patents [OSTI]

    Brainard, John P. (Albuquerque, NM); Christenson, Todd R. (Albuquerque, NM)

    2009-11-03T23:59:59.000Z

    A charge-pump voltage converter for converting a low voltage provided by a low-voltage source to a higher voltage. Charge is inductively generated on a transfer rotor electrode during its transit past an inductor stator electrode and subsequently transferred by the rotating rotor to a collector stator electrode for storage or use. Repetition of the charge transfer process leads to a build-up of voltage on a charge-receiving device. Connection of multiple charge-pump voltage converters in series can generate higher voltages, and connection of multiple charge-pump voltage converters in parallel can generate higher currents. Microelectromechanical (MEMS) embodiments of this invention provide a small and compact high-voltage (several hundred V) voltage source starting with a few-V initial voltage source. The microscale size of many embodiments of this invention make it ideally suited for MEMS- and other micro-applications where integration of the voltage or charge source in a small package is highly desirable.

  14. INTEGRATED GHz VOLTAGE CONTROLLED OSCILLATORS

    E-Print Network [OSTI]

    Kinget, Peter

    INTEGRATED GHz VOLTAGE CONTROLLED OSCILLATORS Peter Kinget Bell Labs - Lucent Technologies Murray Hill, NJ (USA) Abstract The voltage controlled oscillator (VCO) is a critical sub. We focus on the de- sign of a critical sub-block: the voltage controlled oscillator (VCO). We review

  15. Serial Input Output

    SciTech Connect (OSTI)

    Waite, Anthony; /SLAC

    2011-09-07T23:59:59.000Z

    Serial Input/Output (SIO) is designed to be a long term storage format of a sophistication somewhere between simple ASCII files and the techniques provided by inter alia Objectivity and Root. The former tend to be low density, information lossy (floating point numbers lose precision) and inflexible. The latter require abstract descriptions of the data with all that that implies in terms of extra complexity. The basic building blocks of SIO are streams, records and blocks. Streams provide the connections between the program and files. The user can define an arbitrary list of streams as required. A given stream must be opened for either reading or writing. SIO does not support read/write streams. If a stream is closed during the execution of a program, it can be reopened in either read or write mode to the same or a different file. Records represent a coherent grouping of data. Records consist of a collection of blocks (see next paragraph). The user can define a variety of records (headers, events, error logs, etc.) and request that any of them be written to any stream. When SIO reads a file, it first decodes the record name and if that record has been defined and unpacking has been requested for it, SIO proceeds to unpack the blocks. Blocks are user provided objects which do the real work of reading/writing the data. The user is responsible for writing the code for these blocks and for identifying these blocks to SIO at run time. To write a collection of blocks, the user must first connect them to a record. The record can then be written to a stream as described above. Note that the same block can be connected to many different records. When SIO reads a record, it scans through the blocks written and calls the corresponding block object (if it has been defined) to decode it. Undefined blocks are skipped. Each of these categories (streams, records and blocks) have some characteristics in common. Every stream, record and block has a name with the condition that each stream, record or block name must be unique in its category (i.e. all streams must have different names, but a stream can have the same name as a record). Each category is an arbitrary length list which is handled by a 'manager' and there is one manager for each category.

  16. Input a journal Viewing Journals

    E-Print Network [OSTI]

    Sussex, University of

    Journals Contents: Input a journal Viewing Journals Deleting a journal Entering jnl into different period Problems Input a journal 1 Login to Bluqube 2 Select 3 Enter relevant Doc type To select the number of journals you will processing & the total credit value 6 Click on 7 Enter brief description 8

  17. Temperature controlled high voltage regulator

    DOE Patents [OSTI]

    Chiaro, Jr., Peter J. (Clinton, TN); Schulze, Gerald K. (Knoxville, TN)

    2004-04-20T23:59:59.000Z

    A temperature controlled high voltage regulator for automatically adjusting the high voltage applied to a radiation detector is described. The regulator is a solid state device that is independent of the attached radiation detector, enabling the regulator to be used by various models of radiation detectors, such as gas flow proportional radiation detectors.

  18. A Noise-Shaped Switched-Capacitor DC-DC Voltage Regulator A. Rao, W.McIntyre 1

    E-Print Network [OSTI]

    Moon, Un-Ku

    -dc converter with fractional gains. The charge pump used to convert the input voltage acts as a D/A converter the inductive conversion topology has been the standard solution to providing a constant and stable voltage from a battery. With the continued shrinking of the hand-held devices as cell phones, PDA's, pagers and laptops

  19. Dynamic simulation of voltage collapses

    SciTech Connect (OSTI)

    Deuse, J.; Stubbe, M. (Tractebel, Brussels (Belgium))

    1993-08-01T23:59:59.000Z

    Most of the time the voltage collapse phenomena are studied by means of computer programs designed for the calculation of steady state conditions. But in the real world, the simultaneous occurrences of losses of synchronism, of AVR dynamics or of transformer tap changes call for a full dynamic simulation of voltage phenomena. The present paper shows some examples of dynamic simulations of voltage phenomena using a new general purpose stability program (EUROSTAG), covering in a continuous way the classical fields of transient, mid-term and long-term stability, and also the quasi steady state conditions of a power system.

  20. A DSP based real time power quality measurement system with voltage distortion improvement capability 

    E-Print Network [OSTI]

    Gou, Jian

    1992-01-01T23:59:59.000Z

    have been established to specify the limitation on the magnitudes of both harmonic currents and harmonic voltage distortion at different frequencies. Among these the "IEEE Guide for Harmonic Control and Reactive Compensation of Static Power... by the utility and by the electricity consumer has arrived. These measurements include: current and voltage harmonics, input power 1'actor, reactive power, real power, total harmonic distortion (THD), percentage load unbalance, etc. The measured data can...

  1. Saving Megawatts with Voltage Optimization

    E-Print Network [OSTI]

    Wilson, T.; Bell, D.

    2010-01-01T23:59:59.000Z

    that had been installed at several electric utility distribution substations in the U.S. and Canada. These systems, being operated in Conservation Voltage Regulation mode, have provided significant energy conservation where they have been installed...

  2. Voltage tunable microwave ferrite resonator

    E-Print Network [OSTI]

    Oates, Daniel E.

    A novel method of implementing a tunable resonator using an applied voltage is presented. Stress is used to tune a microstrip resonator fabricated on a polycrystalline ferrite substrate. The stress was applied either ...

  3. ABBGroup-1-High voltage lab

    E-Print Network [OSTI]

    Basse, Nils Plesner

    . GENERATION System voltage: 12-24 kV Rated current: 6000-24000 A Max. short-circuit current: 50-500 kA TRANSMISSION System voltage: 72-800 kV Rated current: 2500-4000 A Max. short-circuit current: 25-63 k. It is designed to protect an electrical circuit from damage caused by overload or short-circuit. A circuit

  4. A Matter of Quantum Voltages

    SciTech Connect (OSTI)

    Sellner, Bernhard; Kathmann, Shawn M.

    2014-11-14T23:59:59.000Z

    Voltages inside matter are relevant to crystallization, materials science, biology, catalysis, and aqueous chemistry. Electron holography is able to measure the variation of voltages in matter and modern supercomputers allow the calculation of quantum voltages with practically unlimited spatial and temporal resolution of bulk systems. Of particular interest is the Mean Inner Potential (Vo) - the spatial average of these voltages. Voltages are very sensitive to the distribution of electrons and provide metrics to understand interactions in condensed phases. In the present study, we find excellent agreement with measurements of Vo for vitrified water and salt crystals and demonstrate the impact of covalent and ionic bonding as well as intermolecular/atomic interactions. Furthermore, we predict Vo as well as the fluctuations of these voltages in aqueous NaCl electrolytes and characterize the changes in their behavior as the resolution increases below the size of atoms. This work was supported by the U.S. Department of Energy, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences & Biosciences. Pacific Northwest National Laboratory (PNNL) is a multiprogram national laboratory operated for DOE by Battelle. This research used resources of the National Energy Research Scientific Computing Center, which is supported by the Office of Science of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231.

  5. Temperature-aware NBTI modeling and the impact of input vector control on performance degradation

    E-Print Network [OSTI]

    Wang, Yu

    Temperature-aware NBTI modeling and the impact of input vector control on performance degradation performance degradation in dig- ital circuits by affecting PMOS threshold voltage, is emerging as one devices and propose a novel temporal performance degradation model for digital cir- cuits considering

  6. Input Validation Errors and Defenses

    E-Print Network [OSTI]

    Sekar, R.

    = "gpg -r $send_to_list 2>&1" popen($command) · Attack: user fills in the following information-independent policies are preferable Example: SquirrelMail Command Injection Incoming Request (Untrusted input) $command="gpg popen($command) $send_to_list = $_GET[`sendto'] $command = "gpg -r $send_to_list 2>&1" Outgoing Request

  7. Voltage, energy and power in electric circuits

    E-Print Network [OSTI]

    Berzins, M.

    Voltage, energy and power in electric circuits Science teaching unit #12;Disclaimer The Department-2008DVD-EN Voltage, energy and power in electric circuits #12;#12;© Crown copyright 2008 1The National Strategies | Secondary Voltage, energy and power in electric circuits 00094-2008DVD-EN Contents Voltage

  8. Dynamic Voltage and Frequency Scaling Control for Crossbars in Input-Queued Switches

    E-Print Network [OSTI]

    difficult to achieve. Reducing this thermal dissipation "bottleneck", or reducing the on-chip power the static power, due to leakage currents, since it tends to be proportional to the occupied area and can Abstract--The power consumption in chips, in general, and in crossbars switching fabrics, in particular

  9. Impact of Inductor Placement on the Performance of Adjustable Speed Drives Under Input Voltage Unbalance and

    E-Print Network [OSTI]

    Lipo, Thomas

    Engineering Dr. Madison, WI 53706 #12;IEEE 2005 International Electric Machines and Drives Conference (IEMDC a year to outages and another $6.7 billion each year to power quality phenomena [4]. Among various power]. Such current transients may be caused by a variety of electrical phenomena including motor starting

  10. Ancillary service details: Voltage control

    SciTech Connect (OSTI)

    Kirby, B.; Hirst, E.

    1997-12-01T23:59:59.000Z

    Voltage control is accomplished by managing reactive power on an alternating-current power system. Reactive power can be produced and absorbed by both generation and transmission equipment. Reactive-power devices differ substantially in the magnitude and speed of response and in their capital costs. System operators, transmission owners, generators, customers, power marketers, and government regulators need to pay close attention to voltage control as they restructure the U.S. electricity industry. Voltage control can affect reliability and commerce in three ways: (1) Voltages must be maintained within an acceptable range for both customer and power-system equipment to function properly. (2) The movement of reactive power consumes transmission resources, which limits the ability to move real power and worsens congestion. (3) The movement of reactive power results in real-power losses. When generators are required to supply excessive amounts of reactive power, their real-power production must be curtailed. These opportunity costs are not currently compensated for in most regions. Current tariffs are based on embedded costs. These embedded-cost tariffs average about $0.51/MWh, equivalent to $1.5 billion annually for the United States as a whole. Although this cost is low when compared with the cost of energy, it still aggregates to a significant amount of money. This report takes a basic look at why the power system requires reactive power (an appendix explains the fundamentals of real and reactive power). The report then examines the various types of generation and transmission resources used to supply reactive power and to control voltage. Finally it discusses how these resources are deployed and paid for in several reliability regions around the country. As the U.S. electricity industry is restructured, the generation, transmission, and system-control equipment and functions that maintain voltages within the appropriate ranges are being deintegrated.

  11. High voltage MOSFET switching circuit

    DOE Patents [OSTI]

    McEwan, T.E.

    1994-07-26T23:59:59.000Z

    The problem of source lead inductance in a MOSFET switching circuit is compensated for by adding an inductor to the gate circuit. The gate circuit inductor produces an inductive spike which counters the source lead inductive drop to produce a rectangular drive voltage waveform at the internal gate-source terminals of the MOSFET. 2 figs.

  12. High voltage MOSFET switching circuit

    DOE Patents [OSTI]

    McEwan, Thomas E. (Livermore, CA)

    1994-01-01T23:59:59.000Z

    The problem of source lead inductance in a MOSFET switching circuit is compensated for by adding an inductor to the gate circuit. The gate circuit inductor produces an inductive spike which counters the source lead inductive drop to produce a rectangular drive voltage waveform at the internal gate-source terminals of the MOSFET.

  13. Voltage sensing systems and methods for passive compensation of temperature related intrinsic phase shift

    DOE Patents [OSTI]

    Davidson, James R. (Idaho Falls, ID); Lassahn, Gordon D. (Idaho Falls, ID)

    2001-01-01T23:59:59.000Z

    A small sized electro-optic voltage sensor capable of accurate measurement of high levels of voltages without contact with a conductor or voltage source is provided. When placed in the presence of an electric field, the sensor receives an input beam of electromagnetic radiation into the sensor. A polarization beam displacer serves as a filter to separate the input beam into two beams with orthogonal linear polarizations. The beam displacer is oriented in such a way as to rotate the linearly polarized beams such that they enter a Pockels crystal at a preferred angle of 45 degrees. The beam displacer is therefore capable of causing a linearly polarized beam to impinge a crystal at a desired angle independent of temperature. The Pockels electro-optic effect induces a differential phase shift on the major and minor axes of the input beam as it travels through the Pockels crystal, which causes the input beam to be elliptically polarized. A reflecting prism redirects the beam back through the crystal and the beam displacer. On the return path, the polarization beam displacer separates the elliptically polarized beam into two output beams of orthogonal linear polarization representing the major and minor axes. In crystals that introduce a phase differential attributable to temperature, a compensating crystal is provided to cancel the effect of temperature on the phase differential of the input beam. The system may include a detector for converting the output beams into electrical signals, and a signal processor for determining the voltage based on an analysis of the output beams. The output beams are amplitude modulated by the frequency of the electric field and the amplitude of the output beams is proportional to the magnitude of the electric field, which is related to the voltage being measured.

  14. High voltage photovoltaic power converter

    DOE Patents [OSTI]

    Haigh, Ronald E. (Arvada, CO); Wojtczuk, Steve (Cambridge, MA); Jacobson, Gerard F. (Livermore, CA); Hagans, Karla G. (Livermore, CA)

    2001-01-01T23:59:59.000Z

    An array of independently connected photovoltaic cells on a semi-insulating substrate contains reflective coatings between the cells to enhance efficiency. A uniform, flat top laser beam profile is illuminated upon the array to produce electrical current having high voltage. An essentially wireless system includes a laser energy source being fed through optic fiber and cast upon the photovoltaic cell array to prevent stray electrical signals prior to use of the current from the array. Direct bandgap, single crystal semiconductor materials, such as GaAs, are commonly used in the array. Useful applications of the system include locations where high voltages are provided to confined spaces such as in explosive detonation, accelerators, photo cathodes and medical appliances.

  15. Recommendation 177: Facilitating Early Public Input

    Broader source: Energy.gov [DOE]

    DOE should initiate consultation meetings with stake holders immediately to allow early public input into the planning for IFDP

  16. Countering Poisonous Inputs with Memetic Neuroevolution

    E-Print Network [OSTI]

    Togelius, Julian

    Countering Poisonous Inputs with Memetic Neuroevolution Julian Togelius1 , Tom Schaul1 , J-dimensional and/or ill-chosen state description. Evidently, some controller inputs are "poisonous also ex- plore which types of inputs are poisonous for two different reinforcement learning problems. 1

  17. Bi-directional power control system for voltage converter

    DOE Patents [OSTI]

    Garrigan, N.R.; King, R.D.; Schwartz, J.E.

    1999-05-11T23:59:59.000Z

    A control system for a voltage converter includes: a power comparator for comparing a power signal on input terminals of the converter with a commanded power signal and producing a power comparison signal; a power regulator for transforming the power comparison signal to a commanded current signal; a current comparator for comparing the commanded current signal with a measured current signal on output terminals of the converter and producing a current comparison signal; a current regulator for transforming the current comparison signal to a pulse width modulator (PWM) duty cycle command signal; and a PWM for using the PWM duty cycle command signal to control electrical switches of the converter. The control system may further include: a command multiplier for converting a voltage signal across the output terminals of the converter to a gain signal having a value between zero (0) and unity (1), and a power multiplier for multiplying the commanded power signal by the gain signal to provide a limited commanded power signal, wherein power comparator compares the limited commanded power signal with the power signal on the input terminals. 10 figs.

  18. Bi-directional power control system for voltage converter

    DOE Patents [OSTI]

    Garrigan, Neil Richard (Niskayuna, NY); King, Robert Dean (Schenectady, NY); Schwartz, James Edward (Slingerlands, NY)

    1999-01-01T23:59:59.000Z

    A control system for a voltage converter includes: a power comparator for comparing a power signal on input terminals of the converter with a commanded power signal and producing a power comparison signal; a power regulator for transforming the power comparison signal to a commanded current signal; a current comparator for comparing the commanded current signal with a measured current signal on output terminals of the converter and producing a current comparison signal; a current regulator for transforming the current comparison signal to a pulse width modulator (PWM) duty cycle command signal; and a PWM for using the PWM duty cycle command signal to control electrical switches of the converter. The control system may further include: a command multiplier for converting a voltage signal across the output terminals of the converter to a gain signal having a value between zero (0) and unity (1), and a power multiplier for multiplying the commanded power signal by the gain signal to provide a limited commanded power signal, wherein power comparator compares the limited commanded power signal with the power signal on the input terminals.

  19. Low power, scalable multichannel high voltage controller

    DOE Patents [OSTI]

    Stamps, James Frederick (Livermore, CA); Crocker, Robert Ward (Fremont, CA); Yee, Daniel Dadwa (Dublin, CA); Dils, David Wright (Fort Worth, TX)

    2008-03-25T23:59:59.000Z

    A low voltage control circuit is provided for individually controlling high voltage power provided over bus lines to a multitude of interconnected loads. An example of a load is a drive for capillary channels in a microfluidic system. Control is distributed from a central high voltage circuit, rather than using a number of large expensive central high voltage circuits to enable reducing circuit size and cost. Voltage is distributed to each individual load and controlled using a number of high voltage controller channel switches connected to high voltage bus lines. The channel switches each include complementary pull up and pull down photo isolator relays with photo isolator switching controlled from the central high voltage circuit to provide a desired bus line voltage. Switching of the photo isolator relays is further controlled in each channel switch using feedback from a resistor divider circuit to maintain the bus voltage swing within desired limits. Current sensing is provided using a switched resistive load in each channel switch, with switching of the resistive loads controlled from the central high voltage circuit.

  20. Low power, scalable multichannel high voltage controller

    DOE Patents [OSTI]

    Stamps, James Frederick (Livermore, CA); Crocker, Robert Ward (Fremont, CA); Yee, Daniel Dadwa (Dublin, CA); Dils, David Wright (Fort Worth, TX)

    2006-03-14T23:59:59.000Z

    A low voltage control circuit is provided for individually controlling high voltage power provided over bus lines to a multitude of interconnected loads. An example of a load is a drive for capillary channels in a microfluidic system. Control is distributed from a central high voltage circuit, rather than using a number of large expensive central high voltage circuits to enable reducing circuit size and cost. Voltage is distributed to each individual load and controlled using a number of high voltage controller channel switches connected to high voltage bus lines. The channel switches each include complementary pull up and pull down photo isolator relays with photo isolator switching controlled from the central high voltage circuit to provide a desired bus line voltage. Switching of the photo isolator relays is further controlled in each channel switch using feedback from a resistor divider circuit to maintain the bus voltage swing within desired limits. Current sensing is provided using a switched resistive load in each channel switch, with switching of the resistive loads controlled from the central high voltage circuit.

  1. Dynamic Voltage Regulation Using Distributed Energy Resources

    SciTech Connect (OSTI)

    Xu, Yan [ORNL; Rizy, D Tom [ORNL; Li, Fangxing [ORNL; Kueck, John D [ORNL

    2007-01-01T23:59:59.000Z

    Many distributed energy resources (DE) are near load centres and equipped with power electronics converters to interface with the grid, therefore it is feasible for DE to provide ancillary services such as voltage regulation, nonactive power compensation, and power factor correction. A synchronous condenser and a microturbine with an inverter interface are implemented in parallel in a distribution system to regulate the local voltage. Voltage control schemes of the inverter and the synchronous condenser are developed. The experimental results show that both the inverter and the synchronous condenser can regulate the local voltage instantaneously, while the dynamic response of the inverter is faster than the synchronous condenser; and that integrated voltage regulation (multiple DE perform voltage regulation) can increase the voltage regulation capability, increase the lifetime of the equipment, and reduce the capital and operation costs.

  2. Voltage Vehicles | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro IndustriesTown of Ladoga,planningFlowmeterUtah: Energydba Vision Motor CorpEIAVogtVoltage

  3. Wind Power Plant Voltage Stability Evaluation: Preprint

    SciTech Connect (OSTI)

    Muljadi, E.; Zhang, Y. C.

    2014-09-01T23:59:59.000Z

    Voltage stability refers to the ability of a power system to maintain steady voltages at all buses in the system after being subjected to a disturbance from a given initial operating condition. Voltage stability depends on a power system's ability to maintain and/or restore equilibrium between load demand and supply. Instability that may result occurs in the form of a progressive fall or rise of voltages of some buses. Possible outcomes of voltage instability are the loss of load in an area or tripped transmission lines and other elements by their protective systems, which may lead to cascading outages. The loss of synchronism of some generators may result from these outages or from operating conditions that violate a synchronous generator's field current limit, or in the case of variable speed wind turbine generator, the current limits of power switches. This paper investigates the impact of wind power plants on power system voltage stability by using synchrophasor measurements.

  4. US Nuclear Regulatory Commission Input to DOE Request for Information...

    Energy Savers [EERE]

    US Nuclear Regulatory Commission Input to DOE Request for Information Smart Grid Implementation Input US Nuclear Regulatory Commission Input to DOE Request for Information Smart...

  5. Group 3: Humidity, Temperature, and Voltage (Presentation)

    SciTech Connect (OSTI)

    Wohlgemuth, J.

    2013-05-01T23:59:59.000Z

    Group 3 is chartered to develop accelerated stress tests that can be used as comparative predictors of module lifetime versus stresses associated with humidity, temperature and voltage.

  6. Sacramento Area Voltage Support - Environment - Sierra Nevada...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    (SMUD), Roseville Electric (Roseville), and the California Independent System Operator (ISO) grid. Western prepared a Sacramento Voltage Support (SVS) Draft Environmental Impact...

  7. Code input alternatives John C. Wright

    E-Print Network [OSTI]

    Wright, John C.

    Code input alternatives John C. Wright John Wright Oct 2009 ­ CSWIM Workshop@ORNL Extensible markup, #type, #value, #units, #help idebug, logical, 1, "", "Turn;Summary Use a data-centric model for input creation (code namelists, IPS config file, etc) Database

  8. Capturing power at higher voltages from arrays of microbial fuel cells without voltage reversal

    E-Print Network [OSTI]

    is too low to be used directly for many practical applications. For example, a single light emitting diode (LED) requires a minimum voltage of 2 V.2 Thus, effective methods of boosting MFC voltages

  9. The Constant Voltage Transformer (CVT) for Mitigating Effects of Voltage Sags on Industrial Equipment

    E-Print Network [OSTI]

    Ferraro, R. J.; Osborne, R.; Stephens, R.

    ) an increase in loads that use power electronics in some type of power conversion configuration [1][2]. This paper presents applications of the constant-voltage transformer (CVT) for mitigating the effects of electric service voltage sags on industrial...

  10. 3430 IEEE TRANSACTIONS ON VEHICULAR TECHNOLOGY, VOL. 61, NO. 8, OCTOBER 2012 Experimental Validation of High-Voltage-Ratio

    E-Print Network [OSTI]

    Simões, Marcelo Godoy

    -voltage current-source like device that produces electricity and heat directly from input hydrogen and oxygen carbon dioxide emissions under the assumption that the hydrogen can be produced from renewable-energy sources such as photovoltaic and wind energy or as a subprod- uct of currently wasted energy of large

  11. U-147:Red Hat Enterprise MRG Grid Input Validation Flaw

    Broader source: Energy.gov [DOE]

    The MRG Management Console (Cumin) does not properly filter HTML code from user-supplied input before displaying the input.

  12. Optimal Power Flow Incorporating Voltage Collapse Constraints

    E-Print Network [OSTI]

    Cañizares, Claudio A.

    Optimal Power Flow Incorporating Voltage Collapse Constraints William Rosehart Claudio Ca on the current operating con- ditions is presented. Second, an Optimal Power Flow formulation that incorporates: Voltage Collapse, Optimal Power Flow, Bifur- cations. I. Introduction As open-access market principles

  13. Voltage regulation in linear induction accelerators

    DOE Patents [OSTI]

    Parsons, William M. (Santa Fe, NM)

    1992-01-01T23:59:59.000Z

    Improvement in voltage regulation in a Linear Induction Accelerator wherein a varistor, such as a metal oxide varistor, is placed in parallel with the beam accelerating cavity and the magnetic core. The non-linear properties of the varistor result in a more stable voltage across the beam accelerating cavity than with a conventional compensating resistance.

  14. Voltage regulation in linear induction accelerators

    DOE Patents [OSTI]

    Parsons, W.M.

    1992-12-29T23:59:59.000Z

    Improvement in voltage regulation in a linear induction accelerator wherein a varistor, such as a metal oxide varistor, is placed in parallel with the beam accelerating cavity and the magnetic core is disclosed. The non-linear properties of the varistor result in a more stable voltage across the beam accelerating cavity than with a conventional compensating resistance. 4 figs.

  15. REDUCTION OF VOLTAGE VIOLATIONS FROM EMBEDDED GENERATORS

    E-Print Network [OSTI]

    Harrison, Gareth

    , and on the active and reactive power exported from the local busbar. Line power flow is reduced by local demand be used to attempt to maintain voltage. Recent work has considered the use of embedded diesel generators) If the EG tried to meet an excessive demand for reactive power, as voltage continued to fall, the AVR could

  16. Flexible method for monitoring fuel cell voltage

    DOE Patents [OSTI]

    Mowery, Kenneth D. (Noblesville, IN); Ripley, Eugene V. (Russiaville, IN)

    2002-01-01T23:59:59.000Z

    A method for equalizing the measured voltage of each cluster in a fuel cell stack wherein at least one of the clusters has a different number of cells than the identical number of cells in the remaining clusters by creating a pseudo voltage for the different cell numbered cluster. The average cell voltage of the all of the cells in the fuel cell stack is calculated and multiplied by a constant equal to the difference in the number of cells in the identical cell clusters and the number of cells in the different numbered cell cluster. The resultant product is added to the actual voltage measured across the different numbered cell cluster to create a pseudo voltage which is equivalent in cell number to the number of cells in the other identical numbered cell clusters.

  17. Corona and Motor Voltage Interim Report

    SciTech Connect (OSTI)

    Hsu, J.S.

    2005-05-06T23:59:59.000Z

    It has been suggested that to meet the FreedomCAR objectives for cost, size, weight, efficiency, and reliability higher buss voltages be utilized in HEV and FC automotive applications. The reasoning is that since electric power is equal to the product of voltage and current for a given power a higher voltage and lower current would result in smaller cable and inverter switching components. Consequently, the system can be lighter and smaller. On the other hand, higher voltages are known to require better and thicker electrical insulation that reduce the available slot area for motor windings. One cause of slow insulation breakdown is corona that gradually erodes the insulation and shortens the life expectancy of the motor. This study reports on the results of a study on corona initiating voltages for mush-wound and bobbin-wound stators. A unique testing method is illustrated.

  18. Non-contact current and voltage sensor

    DOE Patents [OSTI]

    Carpenter, Gary D; El-Essawy, Wael; Ferreira, Alexandre Peixoto; Keller, Thomas Walter; Rubio, Juan C; Schappert, Michael A

    2014-03-25T23:59:59.000Z

    A detachable current and voltage sensor provides an isolated and convenient device to measure current passing through a conductor such as an AC branch circuit wire, as well as providing an indication of an electrostatic potential on the wire, which can be used to indicate the phase of the voltage on the wire, and optionally a magnitude of the voltage. The device includes a housing that contains the current and voltage sensors, which may be a ferrite cylinder with a hall effect sensor disposed in a gap along the circumference to measure current, or alternative a winding provided through the cylinder along its axis and a capacitive plate or wire disposed adjacent to, or within, the ferrite cylinder to provide the indication of the voltage.

  19. Wide-range voltage modulation

    SciTech Connect (OSTI)

    Rust, K.R.; Wilson, J.M.

    1992-06-01T23:59:59.000Z

    The Superconducting Super Collider`s Medium Energy Booster Abort (MEBA) kicker modulator will supply a current pulse to the abort magnets which deflect the proton beam from the MEB ring into a designated beam stop. The abort kicker will be used extensively during testing of the Low Energy Booster (LEB) and the MEB rings. When the Collider is in full operation, the MEBA kicker modulator will abort the MEB beam in the event of a malfunction during the filling process. The modulator must generate a 14-{mu}s wide pulse with a rise time of less than 1 {mu}s, including the delay and jitter times. It must also be able to deliver a current pulse to the magnet proportional to the beam energy at any time during ramp-up of the accelerator. Tracking the beam energy, which increases from 12 GeV at injection to 200 GeV at extraction, requires the modulator to operate over a wide range of voltages (4 kV to 80 kV). A vacuum spark gap and a thyratron have been chosen for test and evaluation as candidate switches for the abort modulator. Modulator design, switching time delay, jitter and pre-fire data are presented.

  20. PH-315 A. La Rosa VOLTAGE-CONTROLLED OSCILLATOR

    E-Print Network [OSTI]

    PH-315 A. La Rosa VOLTAGE-CONTROLLED OSCILLATOR 1. PURPOSE: An integrator and a Schmitt Trigger voltage; hence its name "voltage-controlled oscillator." 2. VOLTAGE-CONTROLLED OSCILLATOR Figure 1 shows voltage. An unusual feature of the circuit is its operation using a single positive supply.1 #12;- + 50k V

  1. Generation of RTL verification input stimulus

    E-Print Network [OSTI]

    Selvarathinam, Anand Manivannan

    2001-01-01T23:59:59.000Z

    This thesis presents an approach for generating input stimulus for verification of register-transfer level (RTL) design of VLSI circuits. RTL design is often subjected to a significant verification effort due to errors introduced during manual...

  2. Electro-optical voltage sensor head

    DOE Patents [OSTI]

    Woods, Gregory K. (Idaho Falls, ID)

    1998-01-01T23:59:59.000Z

    A miniature electro-optic voltage sensor system capable of accurate operation at high voltages. The system employs a transmitter, a sensor disposed adjacent to but out of direct electrical contact with a conductor on which the voltage is to be measured, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor where the beam undergoes the Pockels electro-optic effect. The electro-optic effect causes phase shifting in the beam, which is in turn converted to a pair of independent beams, from which the voltage of a system based on its E-field is determined when the two beams are normalized by the signal processor. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse whose ellipticity varies between -1 and +1 in proportion to voltage) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

  3. Voltage instability: Mechanisms and control strategies

    SciTech Connect (OSTI)

    Vu, K.T. [ABB Transmission Technology Inst., Raleigh, NC (United States). Power Systems Center] [ABB Transmission Technology Inst., Raleigh, NC (United States). Power Systems Center; Liu, C.C. [Univ. of Washington, Seattle, WA (United States)] [Univ. of Washington, Seattle, WA (United States); Taylor, C.W. [Bonneville Power Administration, Portland, OR (United States)] [Bonneville Power Administration, Portland, OR (United States); Jimma, K.M. [Puget Sound Power and Light Co., Bellevue, WA (United States)] [Puget Sound Power and Light Co., Bellevue, WA (United States)

    1995-11-01T23:59:59.000Z

    One of the main objectives in operating an electric power system is to maintain a proper voltage level throughout a system. Failure to do so can lead to equipment damage and blackout. The article discusses the nonlinear aspects of power systems, with emphasis on voltage instability. It provides an overview of the state-of-the-art on the analysis and control of voltage dynamics. Dynamic mechanisms and control strategies are discussed from both theoretical and practical standpoints. The remedial controls implemented in the Puget Sound region of the Pacific Northwest indicate the practical significance of the research area.

  4. Modular high voltage power supply for chemical analysis

    DOE Patents [OSTI]

    Stamps, James F. (Livermore, CA); Yee, Daniel D. (Dublin, CA)

    2010-05-04T23:59:59.000Z

    A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

  5. Modular high voltage power supply for chemical analysis

    SciTech Connect (OSTI)

    Stamps, James F. (Livermore, CA); Yee, Daniel D. (Dublin, CA)

    2007-01-09T23:59:59.000Z

    A high voltage power supply for use in a system such as a microfluidics system, uses a DC--DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC--DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

  6. Modular high voltage power supply for chemical analysis

    SciTech Connect (OSTI)

    Stamps, James F. (Livermore, CA); Yee, Daniel D. (Dublin, CA)

    2008-07-15T23:59:59.000Z

    A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

  7. Device for modular input high-speed multi-channel digitizing of electrical data

    DOE Patents [OSTI]

    VanDeusen, A.L.; Crist, C.E.

    1995-09-26T23:59:59.000Z

    A multi-channel high-speed digitizer module converts a plurality of analog signals to digital signals (digitizing) and stores the signals in a memory device. The analog input channels are digitized simultaneously at high speed with a relatively large number of on-board memory data points per channel. The module provides an automated calibration based upon a single voltage reference source. Low signal noise at such a high density and sample rate is accomplished by ensuring the A/D converters are clocked at the same point in the noise cycle each time so that synchronous noise sampling occurs. This sampling process, in conjunction with an automated calibration, yields signal noise levels well below the noise level present on the analog reference voltages. 1 fig.

  8. Device for modular input high-speed multi-channel digitizing of electrical data

    DOE Patents [OSTI]

    VanDeusen, Alan L. (Lee's Summit, MO); Crist, Charles E. (Waxahachie, TX)

    1995-09-26T23:59:59.000Z

    A multi-channel high-speed digitizer module converts a plurality of analog signals to digital signals (digitizing) and stores the signals in a memory device. The analog input channels are digitized simultaneously at high speed with a relatively large number of on-board memory data points per channel. The module provides an automated calibration based upon a single voltage reference source. Low signal noise at such a high density and sample rate is accomplished by ensuring the A/D converters are clocked at the same point in the noise cycle each time so that synchronous noise sampling occurs. This sampling process, in conjunction with an automated calibration, yields signal noise levels well below the noise level present on the analog reference voltages.

  9. Voltage Management of Networks with Distributed Generation. 

    E-Print Network [OSTI]

    O'Donnell, James

    2008-01-01T23:59:59.000Z

    At present there is much debate about the impacts and benefits of increasing the amount of generation connected to the low voltage areas of the electricity distribution network. The UK government is under political ...

  10. Low voltage arc formation in railguns

    DOE Patents [OSTI]

    Hawke, R.S.

    1987-11-17T23:59:59.000Z

    A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile. 2 figs.

  11. Low voltage arc formation in railguns

    DOE Patents [OSTI]

    Hawke, Ronald S. (Livermore, CA)

    1987-01-01T23:59:59.000Z

    A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile.

  12. Low voltage arc formation in railguns

    DOE Patents [OSTI]

    Hawke, R.S.

    1985-08-05T23:59:59.000Z

    A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile.

  13. automatic regulator voltage: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Rouzbahan 2013-01-01 12 Optimal Distributed Voltage Regulation in Power Distribution Networks CERN Preprints Summary: In this paper, we address the problem of voltage...

  14. High-Voltage Solid Polymer Batteries for Electric Drive Vehicles...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    High-Voltage Solid Polymer Batteries for Electric Drive Vehicles High-Voltage Solid Polymer Batteries for Electric Drive Vehicles 2012 DOE Hydrogen and Fuel Cells Program and...

  15. Addressing the Voltage Fade Issue with Lithium-Manganese-Rich...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Addressing the Voltage Fade Issue with Lithium-Manganese-Rich Oxide Cathode Materials Addressing the Voltage Fade Issue with Lithium-Manganese-Rich Oxide Cathode Materials 2013 DOE...

  16. Addressing the Voltage Fade Issue with Lithium-Manganese-Rich...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Voltage Fade Issue with Lithium-Manganese-Rich Oxide Cathode Materials Addressing the Voltage Fade Issue with Lithium-Manganese-Rich Oxide Cathode Materials 2012 DOE Hydrogen and...

  17. Constant voltage electro-slag remelting control

    DOE Patents [OSTI]

    Schlienger, M.E.

    1996-10-22T23:59:59.000Z

    A system for controlling electrode gap in an electro-slag remelt furnace has a constant regulated voltage and an electrode which is fed into the slag pool at a constant rate. The impedance of the circuit through the slag pool is directly proportional to the gap distance. Because of the constant voltage, the system current changes are inversely proportional to changes in gap. This negative feedback causes the gap to remain stable. 1 fig.

  18. Group 3: Humidity, Temperature, and Voltage

    Broader source: Energy.gov [DOE]

    This PowerPoint presentation, focused on humidity, temperature and voltage testing, was originally presented by John Wohlgemuth at the NREL 2013 PV Module Reliability Workshop on Feb. 26-27, 2013 in Denver, CO. It summarizes the activities of a working group chartered to develop accelerated stress tests that can be used as comparative predictors of module life versus stresses associated with humidity, temperature and voltage.

  19. Spark gap with low breakdown voltage jitter

    DOE Patents [OSTI]

    Rohwein, Gerald J. (Albuquerque, NM); Roose, Lars D. (Albuquerque, NM)

    1996-01-01T23:59:59.000Z

    Novel spark gap devices and electrodes are disclosed. The novel spark gap devices and electrodes are suitable for use in a variety of spark gap device applications. The shape of the electrodes gives rise to local field enhancements and reduces breakdown voltage jitter. Breakdown voltage jitter of approximately 5% has been measured in spark gaps according the invention. Novel electrode geometries and materials are disclosed.

  20. Spark gap with low breakdown voltage jitter

    DOE Patents [OSTI]

    Rohwein, G.J.; Roose, L.D.

    1996-04-23T23:59:59.000Z

    Novel spark gap devices and electrodes are disclosed. The novel spark gap devices and electrodes are suitable for use in a variety of spark gap device applications. The shape of the electrodes gives rise to local field enhancements and reduces breakdown voltage jitter. Breakdown voltage jitter of approximately 5% has been measured in spark gaps according the invention. Novel electrode geometries and materials are disclosed. 13 figs.

  1. Total Blender Net Input of Petroleum Products

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are nowTotal" (Percent) Type: Sulfur Content API GravityDakota" "Fuel, quality", 2013,Iowa"Dakota"YearProductionShaleInput Product: Total Input Natural

  2. Green Computing input for better outcomes

    E-Print Network [OSTI]

    Amir, Yair

    Journal Profile: Udi Dahan Green Maturity Model for Virtualization Profiling Energy Usage for Efficient suggests that tracking energy consumption at every level will become the factor of success for greenGreen Computing input for better outcomes Learn the discipline, pursue the art, and contribute

  3. SWAT 2012 Input/Output Documentation

    E-Print Network [OSTI]

    Arnold, J.G.; Kiniry, J.R.; Srinivasan, R.; Williams, J.R.; Haney, E.B.; Neitsch, S.L.

    2013-03-04T23:59:59.000Z

    The Soil and Water Assessment Tool (SWAT) is a comprehensive model that requires a diversity of information in order to run. Novice users may feel overwhelmed by the variety and number of inputs when they first begin to use the model. This document...

  4. Consanguine Calculations Input File: blood.in

    E-Print Network [OSTI]

    California at Berkeley, University of

    1 of 20 Problem A+ Consanguine Calculations Input File: blood.in Every person's blood has 2 markers in a particular ABO blood type for that person. Combination ABO Blood Type AA A AB AB AO A BB B BO B OO O Likewise, every person has two alleles for the blood Rh factor, represented by the characters + and -. Someone who

  5. Asynchronous vs Synchronous Input-Queued Switches

    E-Print Network [OSTI]

    of high-performance switches. 1 INTRODUCTION A vast technical literature exists on input-queued (IQ to performance losses in comparison with synchronous cell switching, these losses are limited, and may be smaller than the losses due to the above-mentioned segmenta- tion/reassembly overheads. In real scenarios

  6. Asynchronous vs Synchronous Input-Queued Switches

    E-Print Network [OSTI]

    for the design of high-performance switches. I. INTRODUCTION A vast technical literature exists on input. Unfortunately the technical literature has largely neglected this situation, and concentrated the attention throughput, or to simpler scheduling. Even when the asynchronous operation leads to performance losses

  7. Distribution System Voltage Performance Analysis for High-Penetration Photovoltaics

    SciTech Connect (OSTI)

    Liu, E.; Bebic, J.

    2008-02-01T23:59:59.000Z

    This report examines the performance of commonly used distribution voltage regulation methods under reverse power flow.

  8. U-252: Barracuda Web Filter Input Validation Flaws Permit Cross...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    2: Barracuda Web Filter Input Validation Flaws Permit Cross-Site Scripting Attacks U-252: Barracuda Web Filter Input Validation Flaws Permit Cross-Site Scripting Attacks September...

  9. T-623: HP Business Availability Center Input Validation Hole...

    Broader source: Energy.gov (indexed) [DOE]

    3: HP Business Availability Center Input Validation Hole Permits Cross-Site Scripting Attacks T-623: HP Business Availability Center Input Validation Hole Permits Cross-Site...

  10. V-139: Cisco Network Admission Control Input Validation Flaw...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    9: Cisco Network Admission Control Input Validation Flaw Lets Remote Users Inject SQL Commands V-139: Cisco Network Admission Control Input Validation Flaw Lets Remote Users Inject...

  11. USDA, Departments of Energy and Navy Seek Input from Industry...

    Office of Environmental Management (EM)

    Departments of Energy and Navy Seek Input from Industry to Advance Biofuels for Military and Commercial Transportation USDA, Departments of Energy and Navy Seek Input from Industry...

  12. U-219: Symantec Web Gateway Input Validation Flaws Lets Remote...

    Broader source: Energy.gov (indexed) [DOE]

    9: Symantec Web Gateway Input Validation Flaws Lets Remote Users Inject SQL Commands, Execute Arbitrary Commands, and Change User Passwords U-219: Symantec Web Gateway Input...

  13. Chapter 17. High-Voltage Systems and Dielectric Materials High-Voltage Systems and Dielectric Materials

    E-Print Network [OSTI]

    -Voltage Systems and Dielectric Materials 17-2 RLE Progress Report 152 provides very useful insight into pre-breakdown in high voltage conduction and breakdown phenomena. 1. Mechanisms Behind Positive Streamers and Their Distinct Propagation Modes in Transformer Oil Sponsors This work was supported by ABB Corporate Research

  14. A Charge Pump that Generates Negative High Voltage with Variable Voltage , Eugene Ivanova,

    E-Print Network [OSTI]

    Ayers, Joseph

    A Charge Pump that Generates Negative High Voltage with Variable Voltage Gain Jun Zhaob, , Eugene, Massachusetts 02115, U.S.A. Abstract A cross-coupled structure based charge pump that generates negative high. The proposed negative charge pump is designed to deliver 40 uA with a wide supply range from 2.5V to 5.5V using

  15. Distributed Voltage and Current Control of Multi-Terminal High-Voltage Direct

    E-Print Network [OSTI]

    Dimarogonas, Dimos

    }@kth.se.) Abstract: High-voltage direct current (HVDC) is a commonly used technology for long-distance power for multi-terminal HVDC (MTDC) systems is proposed. Under certain conditions on the controller gains factor behind long-distance power transmission. High-voltage direct current (HVDC) is a commonly used

  16. Electronic circuit for measuring series connected electrochemical cell voltages

    DOE Patents [OSTI]

    Ashtiani, Cyrus N. (West Bloomfield, MI); Stuart, Thomas A. (Toledo, OH)

    2000-01-01T23:59:59.000Z

    An electronic circuit for measuring voltage signals in an energy storage device is disclosed. The electronic circuit includes a plurality of energy storage cells forming the energy storage device. A voltage divider circuit is connected to at least one of the energy storage cells. A current regulating circuit is provided for regulating the current through the voltage divider circuit. A voltage measurement node is associated with the voltage divider circuit for producing a voltage signal which is proportional to the voltage across the energy storage cell.

  17. Experimental validation of a high voltage pulse measurement method.

    SciTech Connect (OSTI)

    Cular, Stefan; Patel, Nishant Bhupendra; Branch, Darren W.

    2013-09-01T23:59:59.000Z

    This report describes X-cut lithium niobate's (LiNbO3) utilization for voltage sensing by monitoring the acoustic wave propagation changes through LiNbO3 resulting from applied voltage. Direct current (DC), alternating current (AC) and pulsed voltage signals were applied to the crystal. Voltage induced shift in acoustic wave propagation time scaled quadratically for DC and AC voltages and linearly for pulsed voltages. The measured values ranged from 10 - 273 ps and 189 ps - 2 ns for DC and non-DC voltages, respectively. Data suggests LiNbO3 has a frequency sensitive response to voltage. If voltage source error is eliminated through physical modeling from the uncertainty budget, the sensor's U95 estimated combined uncertainty could decrease to ~0.025% for DC, AC, and pulsed voltage measurements.

  18. Compact high voltage solid state switch

    DOE Patents [OSTI]

    Glidden, Steven C.

    2003-09-23T23:59:59.000Z

    A compact, solid state, high voltage switch capable of high conduction current with a high rate of current risetime (high di/dt) that can be used to replace thyratrons in existing and new applications. The switch has multiple thyristors packaged in a single enclosure. Each thyristor has its own gate drive circuit that circuit obtains its energy from the energy that is being switched in the main circuit. The gate drives are triggered with a low voltage, low current pulse isolated by a small inexpensive transformer. The gate circuits can also be triggered with an optical signal, eliminating the trigger transformer altogether. This approach makes it easier to connect many thyristors in series to obtain the hold off voltages of greater than 80 kV.

  19. SiGe BiCMOS Topologies for Low-Voltage Millimeter-Wave Voltage Controlled Oscillators and Frequency Dividers

    E-Print Network [OSTI]

    Voinigescu, Sorin Petre

    SiGe BiCMOS Topologies for Low-Voltage Millimeter-Wave Voltage Controlled Oscillators and Frequency-mail: tod@eecg.toronto.edu Abstract -- BiCMOS topologies for mm-wave voltage- controlled oscillators operation for mm-wave applications. II. BICMOS VOLTAGE-CONTROLLED OSCILLATOR The Colpitts topology

  20. On the application of radio frequency voltages to ion traps via helical resonators

    E-Print Network [OSTI]

    J. D. Siverns; L. R. Simkins; S. Weidt; W. K. Hensinger

    2011-10-18T23:59:59.000Z

    Ions confined using a Paul trap require a stable, high voltage and low noise radio frequency (RF) potential. We present a guide for the design and construction of a helical coil resonator for a desired frequency that maximises the quality factor for a set of experimental constraints. We provide an in-depth analysis of the system formed from a shielded helical coil and an ion trap by treating the system as a lumped element model. This allows us to predict the resonant frequency and quality factor in terms of the physical parameters of the resonator and the properties of the ion trap. We also compare theoretical predictions with experimental data for different resonators, and predict the voltage applied to the ion trap as a function of the Q-factor, input power and the properties of the resonant circuit.

  1. The effects of variations in the photocathode voltages of electronic streak cameras

    SciTech Connect (OSTI)

    Bowers, M.W.; Biggs, G.L.; Ronchetto, J.J.; Teruya, A.T.

    1988-08-08T23:59:59.000Z

    Electronic streak cameras are used to record subnanosecond data at the Nevada Test Site. It has been found that externally induced variations in the photocathode voltage of the streak tube can produce both temporal and spatial errors on the output image. An electron beam tracing code was used to model the magnification as a function of photocathode voltage and signal input position for streak tubes manufactured by RCA, ITT, and Kentech. Laboratory tests were also performed where pulsed and radio frequency signals were induced upon the photocathode and the errors on the resultant image were compared with the error predicted by the electron beam code. Also, methods for processing the distortion in digitized images were investigated. This paper will discuss the results of these investigations. 3 refs., 17 figs.

  2. Input to Priorities Panel August 7, 2012

    E-Print Network [OSTI]

    Input to Priorities Panel August 7, 2012 Jeff Freidberg MIT 1 #12;The Emperor of Fusion has · Comparison (1 GW overnight cost) · Coal $ 3B · Gas $ 1B · Nuclear $ 4B · Wind $ 2B · Solar-T $ 3B · ITER $25B option · Tough MHD, heating, current drive, transport · I doubt it will achieve its mission · Still

  3. Soft-Input Soft-Output Sphere Decoding Christoph Studer

    E-Print Network [OSTI]

    Soft-Input Soft-Output Sphere Decoding Christoph Studer Integrated Systems Laboratory ETH Zurich Soft-input soft-output (SISO) detection in multiple-input multiple-output (MIMO) systems constitutes Laboratory ETH Zurich, 8092 Zurich, Switzerland Email: boelcskei@nari.ee.ethz.ch Abstract--Soft-input soft

  4. High voltage photo switch package module

    DOE Patents [OSTI]

    Sullivan, James S; Sanders, David M; Hawkins, Steven A; Sampayan, Stephen E

    2014-02-18T23:59:59.000Z

    A photo-conductive switch package module having a photo-conductive substrate or wafer with opposing electrode-interface surfaces, and at least one light-input surface. First metallic layers are formed on the electrode-interface surfaces, and one or more optical waveguides having input and output ends are bonded to the substrate so that the output end of each waveguide is bonded to a corresponding one of the light-input surfaces of the photo-conductive substrate. This forms a waveguide-substrate interface for coupling light into the photo-conductive wafer. A dielectric material such as epoxy is then used to encapsulate the photo-conductive substrate and optical waveguide so that only the metallic layers and the input end of the optical waveguide are exposed. Second metallic layers are then formed on the first metallic layers so that the waveguide-substrate interface is positioned under the second metallic layers.

  5. Electro-optic voltage sensor for sensing voltage in an E-field

    DOE Patents [OSTI]

    Woods, Gregory K. (Idaho Falls, ID); Renak, Todd W. (Idaho Falls, ID)

    1999-01-01T23:59:59.000Z

    A miniature electro-optic voltage sensor system capable of accurate operation at high voltages. The system employs a transmitter, a sensor disposed adjacent to but out of direct electrical contact with a conductor on which the voltage is to be measured, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor where the beam undergoes the Pockels electro-optic effect. The electro-optic effect causes phase shifting in the beam, which is in turn converted to a pair of independent beams, from which the voltage of a system based on its E-field is determined when the two beams are normalized by the signal processor. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse whose ellipticity varies between -1 and +1 in proportion to voltage) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

  6. Electro-optic voltage sensor for sensing voltage in an E-field

    DOE Patents [OSTI]

    Woods, G.K.; Renak, T.W.

    1999-04-06T23:59:59.000Z

    A miniature electro-optic voltage sensor system capable of accurate operation at high voltages is disclosed. The system employs a transmitter, a sensor disposed adjacent to but out of direct electrical contact with a conductor on which the voltage is to be measured, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor where the beam undergoes the Pockels electro-optic effect. The electro-optic effect causes phase shifting in the beam, which is in turn converted to a pair of independent beams, from which the voltage of a system based on its E-field is determined when the two beams are normalized by the signal processor. The sensor converts the beam by splitting the beam in accordance with the axes of the beam`s polarization state (an ellipse whose ellipticity varies between -1 and +1 in proportion to voltage) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured. 18 figs.

  7. Precision voltage regulation on the 5 kHz, 3. 125 MW ETA-II pulsed power system

    SciTech Connect (OSTI)

    Watson, J.A.; Payne, A.N.; Sampayan, S.E.; Ollis, C.W.

    1991-06-01T23:59:59.000Z

    Each of four pulsed power units (PPUs) for the Experimental Test Accelerator 2 (ETA-2) at Lawrence Livermore National Laboratory delivers a 25kV, 20kA, 4{mu}S pulse at a 5kHz repetition rate into a magnetic pulse compression modulator (MAG-1D). In our present configuration, we are capable of producing a 50 pulse burst using a 1000{mu}F capacitor bank. In this configuration, the input voltage to the PPU droops 22% during the burst. Accelerator operating requirements, however, dictate {plus minus}0.1% regulation of the PPU output voltage during the burst. We are employing a de-Qing network to achieve this regulation goal. In this paper, we describe an output voltage predict-ahead scheme that we are using to generate de-Q trigger pulses at the proper time to insure accurate regulations. 8 refs., 5 figs.

  8. Voltage control on a train system

    DOE Patents [OSTI]

    Gordon, Susanna P.; Evans, John A.

    2004-01-20T23:59:59.000Z

    The present invention provides methods for preventing low train voltages and managing interference, thereby improving the efficiency, reliability, and passenger comfort associated with commuter trains. An algorithm implementing neural network technology is used to predict low voltages before they occur. Once voltages are predicted, then multiple trains can be controlled to prevent low voltage events. Further, algorithms for managing inference are presented in the present invention. Different types of interference problems are addressed in the present invention such as "Interference During Acceleration", "Interference Near Station Stops", and "Interference During Delay Recovery." Managing such interference avoids unnecessary brake/acceleration cycles during acceleration, immediately before station stops, and after substantial delays. Algorithms are demonstrated to avoid oscillatory brake/acceleration cycles due to interference and to smooth the trajectories of closely following trains. This is achieved by maintaining sufficient following distances to avoid unnecessary braking/accelerating. These methods generate smooth train trajectories, making for a more comfortable ride, and improve train motor reliability by avoiding unnecessary mode-changes between propulsion and braking. These algorithms can also have a favorable impact on traction power system requirements and energy consumption.

  9. High Voltage Electrolyte for Lithium Batteries

    Broader source: Energy.gov (indexed) [DOE]

    Argonne's Fluorinated Compounds as High Voltage Electrolytes (HVEs) O O O O O O EC EMC O O O CF CF 3 CF 3 O O O CF 3 F 2 HC C F 2 O F 2 C CF 2 H 6 Code Name Chemical...

  10. Group 3: Humidity, Temperature and Voltage (Presentation)

    SciTech Connect (OSTI)

    Wohlgemuth, J.

    2013-09-01T23:59:59.000Z

    This is a summary of the work of Group 3 of the International PV QA Task Force. Group 3 is chartered to develop accelerated stress tests that can be used as comparative predictors of module lifetime versus stresses associated with humidity, temperature and voltage.

  11. Real-time control of PWM voltage source inverters using the TMS320C30 digital signal processing microprocessor

    E-Print Network [OSTI]

    Mitrani, Michael

    1994-01-01T23:59:59.000Z

    implementation for different control schemes. Real-time, closed- loop feedback techniques minimize output harmonic content and compensate for non- linear and unbalanced loads. Traditionally, PWM drives for power inverters have been implemented using analog... The Spectmm card is connected to three separate modules: 1. Voltage Sense 2. Parallel Port The DC supply, inverter and output filters comprise the power inverter. The inverter has input connections for TTL-level triggering signals for each of the three...

  12. Distribution System Voltage Regulation by Distributed Energy Resources

    SciTech Connect (OSTI)

    Ceylan, Oguzhan [ORNL; Liu, Guodong [ORNL; Xu, Yan [ORNL; Tomsovic, Kevin [University of Tennessee, Knoxville (UTK)

    2014-01-01T23:59:59.000Z

    This paper proposes a control method to regulate voltages in 3 phase unbalanced electrical distribution systems. A constrained optimization problem to minimize voltage deviations and maximize distributed energy resource (DER) active power output is solved by harmony search algorithm. IEEE 13 Bus Distribution Test System was modified to test three different cases: a) only voltage regulator controlled system b) only DER controlled system and c) both voltage regulator and DER controlled system. The simulation results show that systems with both voltage regulators and DER control provide better voltage profile.

  13. Multilevel Cascade H-bridge Inverter DC Voltage Estimation Through Output Voltage Sensing

    E-Print Network [OSTI]

    Tolbert, Leon M.

    system as the inverter power supply may vary. For example, interface of solar panels or fuel cell. The output voltage is then processed by a DSP unit that uses the signals that command the switches

  14. Ground motion input in seismic evaluation studies

    SciTech Connect (OSTI)

    Sewell, R.T.; Wu, S.C.

    1996-07-01T23:59:59.000Z

    This report documents research pertaining to conservatism and variability in seismic risk estimates. Specifically, it examines whether or not artificial motions produce unrealistic evaluation demands, i.e., demands significantly inconsistent with those expected from real earthquake motions. To study these issues, two types of artificial motions are considered: (a) motions with smooth response spectra, and (b) motions with realistic variations in spectral amplitude across vibration frequency. For both types of artificial motion, time histories are generated to match target spectral shapes. For comparison, empirical motions representative of those that might result from strong earthquakes in the Eastern U.S. are also considered. The study findings suggest that artificial motions resulting from typical simulation approaches (aimed at matching a given target spectrum) are generally adequate and appropriate in representing the peak-response demands that may be induced in linear structures and equipment responding to real earthquake motions. Also, given similar input Fourier energies at high-frequencies, levels of input Fourier energy at low frequencies observed for artificial motions are substantially similar to those levels noted in real earthquake motions. In addition, the study reveals specific problems resulting from the application of Western U.S. type motions for seismic evaluation of Eastern U.S. nuclear power plants.

  15. Reactive Support and Voltage Control Service: Key Issues and Challenges

    E-Print Network [OSTI]

    Gross, George

    reactive support and voltage control services. Keywords ­ Competitive Electricity Markets, Reactive PowerReactive Support and Voltage Control Service: Key Issues and Challenges George Gross^, Paolo Marannino° and Gianfranco Chicco* ^ Department of Electrical and Computer Engineering, University

  16. Electrical system architecture having high voltage bus

    DOE Patents [OSTI]

    Hoff, Brian Douglas (East Peoria, IL); Akasam, Sivaprasad (Peoria, IL)

    2011-03-22T23:59:59.000Z

    An electrical system architecture is disclosed. The architecture has a power source configured to generate a first power, and a first bus configured to receive the first power from the power source. The architecture also has a converter configured to receive the first power from the first bus and convert the first power to a second power, wherein a voltage of the second power is greater than a voltage of the first power, and a second bus configured to receive the second power from the converter. The architecture further has a power storage device configured to receive the second power from the second bus and deliver the second power to the second bus, a propulsion motor configured to receive the second power from the second bus, and an accessory motor configured to receive the second power from the second bus.

  17. Low Voltage White Phosphorescent OLED Achievements

    Broader source: Energy.gov [DOE]

    Universal Display Corporation (UDC) and its research partners at Princeton University and the University of Southern California have succeeded in developing a white phosphorescent OLED (PHOLED™) that achieved a record efficiency of 20 lumens per watt. This achievement is the result of the team's collaborative efforts to increase the efficiency of PHOLED lighting by focusing on two critical factors: lowering the drive voltages and increasing the amount of light extracted.

  18. High Voltage Electrolyte for Lithium Batteries

    Broader source: Energy.gov (indexed) [DOE]

    5.0E-04 1.0E-03 2 2.2 2.4 2.6 2.8 Voltage (V) dQdV (AhV) 1 st Charge 1.2M LiPF 6 ECEMC 37 1 st Charge 1.0M LiPF 6 TMS1NM3 55 with 2% and 4% VC 1 st Charge 1.0M LiPF 6 TMS...

  19. Electrostatically screened, voltage-controlled electrostatic chuck

    DOE Patents [OSTI]

    Klebanoff, Leonard Elliott (San Ramon, CA)

    2001-01-01T23:59:59.000Z

    Employing an electrostatically screened, voltage-controlled electrostatic chuck particularly suited for holding wafers and masks in sub-atmospheric operations will significantly reduce the likelihood of contaminant deposition on the substrates. The electrostatic chuck includes (1) an insulator block having a outer perimeter and a planar surface adapted to support the substrate and comprising at least one electrode (typically a pair of electrodes that are embedded in the insulator block), (2) a source of voltage that is connected to the at least one electrode, (3) a support base to which the insulator block is attached, and (4) a primary electrostatic shield ring member that is positioned around the outer perimeter of the insulator block. The electrostatic chuck permits control of the voltage of the lithographic substrate; in addition, it provides electrostatic shielding of the stray electric fields issuing from the sides of the electrostatic chuck. The shielding effectively prevents electric fields from wrapping around to the upper or front surface of the substrate, thereby eliminating electrostatic particle deposition.

  20. Electro-optic voltage sensor head

    DOE Patents [OSTI]

    Crawford, Thomas M. (Idaho Falls, ID); Davidson, James R. (Idaho Falls, ID); Woods, Gregory K. (Cornelius, OR)

    1999-01-01T23:59:59.000Z

    The invention is an electro-optic voltage sensor head designed for integration with existing types of high voltage transmission and distribution apparatus. The sensor head contains a transducer, which comprises a transducing material in which the Pockels electro-optic effect is observed. In the practice of the invention at least one beam of electromagnetic radiation is routed into the transducing material of the transducer in the sensor head. The beam undergoes an electro-optic effect in the sensor head when the transducing material is subjected to an E-field. The electro-optic effect is observed as a differential phase a shift, also called differential phase modulation, of the beam components in orthogonal planes of the electromagnetic radiation. In the preferred embodiment the beam is routed through the transducer along an initial axis and then reflected by a retro-reflector back substantially parallel to the initial axis, making a double pass through the transducer for increased measurement sensitivity. The preferred embodiment of the sensor head also includes a polarization state rotator and at least one beam splitter for orienting the beam along major and minor axes and for splitting the beam components into two signals which are independent converse amplitude-modulated signals carrying E-field magnitude and hence voltage information from the sensor head by way of optic fibers.

  1. Electro-optic voltage sensor head

    DOE Patents [OSTI]

    Crawford, T.M.; Davidson, J.R.; Woods, G.K.

    1999-08-17T23:59:59.000Z

    The invention is an electro-optic voltage sensor head designed for integration with existing types of high voltage transmission and distribution apparatus. The sensor head contains a transducer, which comprises a transducing material in which the Pockels electro-optic effect is observed. In the practice of the invention at least one beam of electromagnetic radiation is routed into the transducing material of the transducer in the sensor head. The beam undergoes an electro-optic effect in the sensor head when the transducing material is subjected to an E-field. The electro-optic effect is observed as a differential phase a shift, also called differential phase modulation, of the beam components in orthogonal planes of the electromagnetic radiation. In the preferred embodiment the beam is routed through the transducer along an initial axis and then reflected by a retro-reflector back substantially parallel to the initial axis, making a double pass through the transducer for increased measurement sensitivity. The preferred embodiment of the sensor head also includes a polarization state rotator and at least one beam splitter for orienting the beam along major and minor axes and for splitting the beam components into two signals which are independent converse amplitude-modulated signals carrying E-field magnitude and hence voltage information from the sensor head by way of optic fibers. 6 figs.

  2. Loop-voltage tomography in tokamaks using transient synchrotron radiation

    SciTech Connect (OSTI)

    Fisch, N.J.; Kritz, A.H. (Princeton Univ., NJ (USA). Plasma Physics Lab.; Hunter Coll., New York, NY (USA). Dept. of Physics)

    1989-07-01T23:59:59.000Z

    The loop voltage in tokamaks is particularly difficult to measure anywhere but at the plasma periphery. A brief, deliberate, perturbation of hot plasma electrons, however, produces a transient radiation response that is sensitive to this voltage. We investigate how such a radiation response can be used to diagnose the loop voltage. 24 refs., 6 figs.

  3. Characterized ideal LC circuit Charge, current and voltage vary sinusoidally

    E-Print Network [OSTI]

    Bertulani, Carlos A. - Department of Physics and Astronomy, Texas A&M University

    resistance to LC circuit Oscillations become damped Charge, current and voltage still vary sinusoidally Oscillations Draw phasors for voltages of R, C and L at same time t Orient VR, VL, & VC phasors relativeReview Characterized ideal LC circuit Charge, current and voltage vary sinusoidally Added

  4. Accurately measuring current-voltage characteristics of tunnel diodes

    E-Print Network [OSTI]

    Bao, Mingqiang; Wang, Kang L

    2006-01-01T23:59:59.000Z

    of the bias voltage range of oscillations in the I–V curve.and the bias voltage range of oscillation in the I–V curve.or to know the exact voltage range of oscillation in the I–V

  5. DCS1800/WCDMA ADAPTIVE VOLTAGE-CONTROLLED OSCILLATOR

    E-Print Network [OSTI]

    Serdijn, Wouter A.

    DCS1800/WCDMA ADAPTIVE VOLTAGE-CONTROLLED OSCILLATOR Aleksandar Tasiü, Wouter A. Serdijn and John R, an adaptive 2G/3G voltage-controlled oscillator (VCO) is described in this paper. For the DCS1800 operation with this reasoning, an adaptive 2G/3G voltage- controlled oscillator, meant for a dual-standard adaptive front

  6. Simplified VO M&V Protocol Simplified Voltage Optimization (VO)

    E-Print Network [OSTI]

    of all distribution lines that are controlled by a tap changing source voltage regulator. Several voltage-control primary system with source voltage regulation. Minimum system stability thresholds, system data modeling is mentioned, it refers to using industry accepted distribution system power flow simulation tools

  7. Selective compensation of voltage harmonics in grid-connected microgrids

    E-Print Network [OSTI]

    Vasquez, Juan Carlos

    1 Selective compensation of voltage harmonics in grid-connected microgrids Mehdi Savaghebia , Juan is proposed for selective compensation of main voltage harmonics in a grid- connected microgrid. The aim level. Keywords Distributed Generator (DG); microgrid; grid-connected; voltage harmonics compensation. 1

  8. Structural Optimization of High Voltage Transmission Line Towers considering

    E-Print Network [OSTI]

    Colominas, Ignasi

    Structural Optimization of High Voltage Transmission Line Towers considering Continuum and Discrete/or to common designs largely repeated (e.g. automotive compo- nents), and high voltage transmission towers can than conventional designs of high voltage transmission line towers. The optimization model proposed

  9. System for increasing corona inception voltage of insulating oils

    DOE Patents [OSTI]

    Rohwein, G.J.

    1998-05-19T23:59:59.000Z

    The Corona Inception Voltage of insulating oils is increased by repetitive cycles of prestressing the oil with a voltage greater than the corona inception voltage, and either simultaneously or serially removing byproducts of corona by evacuation and heating the oil. 5 figs.

  10. Electrical Circuit Flashover Model of Polluted Insulators under AC Voltage Based on the Arc Root Voltage Gradient Criterion

    E-Print Network [OSTI]

    Yang, Qing

    In order to study the flashover mechanism of polluted insulators under AC voltage, a new arc propagation criterion which is based on an arc root voltage gradient is proposed. This criterion can explain the variation of the ...

  11. V-193: Barracuda SSL VPN Input Validation Hole Permits Cross...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    2.3.3.216 Addthis Related Articles U-252: Barracuda Web Filter Input Validation Flaws Permit Cross-Site Scripting Attacks U-144:Juniper Secure Access Input Validation Flaw Permits...

  12. On the Wind Power Input to the Ocean General Circulation

    E-Print Network [OSTI]

    Zhai, Xiaoming

    The wind power input to the ocean general circulation is usually calculated from the time-averaged wind products. Here, this wind power input is reexamined using available observations, focusing on the role of the synoptically ...

  13. Automatically identifying critical input regions and code in applications

    E-Print Network [OSTI]

    Carbin, Michael James

    Applications that process complex inputs often react in different ways to changes in different regions of the input. Small changes to forgiving regions induce correspondingly small changes in the behavior and output. Small ...

  14. The Intelligent Combination of Input Shaping and PID Feedback Control

    E-Print Network [OSTI]

    Singhose, William

    The Intelligent Combination of Input Shaping and PID Feedback Control A Dissertation Presented Combination of Input Shaping and PID Feedback Control Approved by: Dr. William Singhose, Advisor School . . . . . . . . . . . . . . . . . . . . 8 1.4 PID Feedback Control . . . . . . . . . . . . . . . . . . . . . . . . . . 14 1.5 Comparison

  15. Input Routing Determining the next hop with ip_route_input()

    E-Print Network [OSTI]

    Westall, James M.

    _route_input(struct sk_buff *skb, u32 daddr, u32 saddr, u8 tos, struct net_device *dev) 1624 { 1625 struct rtable * rth; 1626 unsigned hash; 1627 int iif = dev->ifindex; 1628 1629 tos &= IPTOS_RT_MASK; The rt_hash_code(daddr, saddr ^ (iif tos); The hash function is implemented by the inline function rt

  16. CERNA WORKING PAPER SERIES Strategic inputs into patent pools

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    1 CERNA WORKING PAPER SERIES Strategic inputs into patent pools Justus Baron Henry Delcamp Working;2 Strategic inputs into patent pools1 Justus BARON2 Henry DELCAMP3 Abstract: This article explores what factors determine the decision of a patent pool to accept new inputs. We propose a dynamic analysis

  17. Measured voltages and currents internal to closed metal cylinders due to diffusion of simulated lightning currents

    SciTech Connect (OSTI)

    Schnetzer, G.H.; Fisher, R.J.

    1994-08-01T23:59:59.000Z

    One mechanism for the penetration of lightning energy into the interior of a weapon is by current diffusion through the exterior metal case. Tests were conducted in which simulated lightning currents were driven over the exteriors of similar aluminum and ferrous steel cylinders of 0.125-in wall thickness. Under conditions in which the test currents were driven asymmetrically over the exteriors of the cylinders, voltages were measured between various test points in the interior as functions of the amplitude and duration of the applied current. The maximum recorded open-circuit voltage, which occurred in the steel cylinder, was 1.7 V. On separate shots, currents flowing on a low impedance shorting conductor between the same set of test points were also measured, yielding a maximum current of 630 A, again occurring across the interior of the steel cylinder. Under symmetrical exterior drive current conditions, a maximum end-to-end internal voltage of 4.1 V was obtained, also in the steel cylinder, with a corresponding current of 480 A measured on a coaxial conductor connected between the two end plates of the cylinder. Data were acquired over a range of input current amplitudes between about 40 and 100 kA. These data provide the experimental basis for validating models that can subsequently be applied to real weapons and other objects of interest.

  18. Method of Controlling Corona Effects and Breakdown Voltage of Small Air Gaps Stressed by Impulse Voltages

    E-Print Network [OSTI]

    Athanasios Maglaras; Trifon Kousiouris; Frangiskos Topalis; Dimitrios Katsaros; Leandros A. Maglaras; Konstantina Giannakopoulou

    2014-10-15T23:59:59.000Z

    This paper investigates the influence of a resistor on the dielectric behavior of an air gap. The resistor is connected in series with the air gap and the latter is stressed by impulse voltage. Air gap arrangements of different geometry with either the rod or the plate grounded are stressed with impulse voltages of both positive and negative polarity. The resistor is connected in series with the air gap in the return circuit connecting the gap with the impulse generator. The method followed involves the investigation of the graphs of the charging time concerning the air gaps capacitances, in connection to the value of the resistor, the geometry of the gap, the effect of grounding and the polarity effect. It is determined that the charging time of the air gap increases, as the value of the resistor increases. It is also determined that the peak voltage value of the fully charged air gap decreases as the value of the resistor increases. The results of the mathematical and simulation analysis are compared with the results of the oscillograms taken from experimental work. In addition and consequently to the above results it is concluded from the experimental work that the in series connection of the resistor in the circuit has significant influence on corona pulses (partial discharges) occurring in the gap and on the breakdown voltage of the gap. A new method of controlling the corona effects and consequently the breakdown voltage of small air gaps stressed by impulse voltage of short duration in connection to the ground effect and the polarity effect has arisen. Furthermore through mathematical analysis of the charging graphs obtained from simulation and experimental oscillograms there was a calculation of the values of the capacitance of the air gaps in relation to their geometry and the results were compared to the values calculated with mathematical analysis.

  19. Apparatus for producing voltage and current pulses

    DOE Patents [OSTI]

    Kirbie, Hugh (Los Alamos, NM); Dale, Gregory E. (Los Alamos, NM)

    2010-12-21T23:59:59.000Z

    An apparatus having one or more modular stages for producing voltage and current pulses. Each module includes a diode charging means to charge a capacitive means that stores energy. One or more charging impedance means are connected to the diode charging means to provide a return current pathway. A solid-state switch discharge means, with current interruption capability, is connected to the capacitive means to discharge stored energy. Finally, a control means is provided to command the switching action of the solid-state switch discharge means.

  20. Production of high voltage by ion bombardment

    E-Print Network [OSTI]

    Phinney, Lucas Carter

    2003-01-01T23:59:59.000Z

    . . . 35 FIGIJRE Page 19 I-V curve for the ammeter setup . . 35 20 Diagram of the leakage current test setup . . . . . . 37 21 Voltmeter readings at each high voltage interval . . . . . , 38 CHAPTER I INTRODUCTION Direct energy conversion... streaming into the source There is also a moveable shutter that can stop the beam &om entering the beam line. A Varian VHS-6 diffusion pump is connected at the bottom of the glass cross. Its function is to maintain a vacuum in this part of the accelerator...

  1. Eliminate Voltage Unbalance | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the YouTube|6721 Federal Register / Vol.6:Energy|Electrifyingof EnergyVoltage

  2. Planar LTCC transformers for high voltage flyback converters.

    SciTech Connect (OSTI)

    Schofield, Daryl (NASCENT Technology Inc. , Watertown, SD); Schare, Joshua M.; Glass, Sarah Jill; Roesler, Alexander William; Ewsuk, Kevin Gregory; Slama, George (NASCENT Technology Inc. , Watertown, SD); Abel, Dave (NASCENT Technology Inc. , Watertown, SD)

    2007-06-01T23:59:59.000Z

    This paper discusses the design and use of low-temperature (850 C to 950 C) co-fired ceramic (LTCC) planar magnetic flyback transformers for applications that require conversion of a low voltage to high voltage (> 100V) with significant volumetric constraints. Measured performance and modeling results for multiple designs showed that the LTCC flyback transformer design and construction imposes serious limitations on the achievable coupling and significantly impacts the transformer performance and output voltage. This paper discusses the impact of various design factors that can provide improved performance by increasing transformer coupling and output voltage. The experiments performed on prototype units demonstrated LTCC transformer designs capable of greater than 2 kV output. Finally, the work investigated the effect of the LTCC microstructure on transformer insulation. Although this paper focuses on generating voltages in the kV range, the experimental characterization and discussion presented in this work applies to designs requiring lower voltage.

  3. Method for voltage-gated protein fractionation

    DOE Patents [OSTI]

    Hatch, Anson (Tracy, CA); Singh, Anup K. (Danville, CA)

    2012-04-24T23:59:59.000Z

    We report unique findings on the voltage dependence of protein exclusion from the pores of nanoporous polymer exclusion membranes. The pores are small enough that proteins are excluded from passage with low applied electric fields, but increasing the field enables proteins to pass through. The requisite field necessary for a change in exclusion is protein-specific with a correlation to protein size. The field-dependence of exclusion is important to consider for preconcentration applications. The ability to selectively gate proteins at exclusion membranes is also a promising means for manipulating and characterizing proteins. We show that field-gated exclusion can be used to selectively remove proteins from a mixture, or to selectively trap protein at one exclusion membrane in a series.

  4. Voltage controlled MESFET pulse shape generator

    SciTech Connect (OSTI)

    Burkhart, S.C.

    1994-10-26T23:59:59.000Z

    A programmable pulse shape generator capable of producing pulse shapes for Nova and Beamlet has been designed and simulated using the circuit code SPICE. The design utilizes power MESFETS, which are commonly used in microwave amplifiers. The pulse shape is varied by setting a bias voltage on each in a chain of MESFETS with a 200 ps temporal resolution. The electrical pulse then drives an integrated electro-optic modulator similar to what is on Beamlet. Pulse shapes 22 and 25, used on Nova, have been generated by this design. There is no fundamental barrier to making such a pulse generator for use on the National Ignition Facility. In fact, the longer time scales on the NIF pulse will ease the high speed requirements of the pulse shape generator allowing the use of less expensive components. The next step will be to build a prototype circuit for initial testing on Beamlet and Nova.

  5. Submerged Medium Voltage Cable Systems at Nuclear Power Plants...

    Office of Scientific and Technical Information (OSTI)

    Submerged Medium Voltage Cable Systems at Nuclear Power Plants: A Review of Research Efforts Relevant to Aging Mechanisms and Condition Monitoring. Re-direct Destination: In a...

  6. Mitigating Voltage Fade in Cathode Materials by Improving the...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Fade in Cathode Materials by Improving the Atomic Level Uniformity of Elemental Distribution. Mitigating Voltage Fade in Cathode Materials by Improving the Atomic Level...

  7. Nanoscale Morphological and Chemical Changes of High Voltage...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Nanoscale Morphological and Chemical Changes of High Voltage Lithium-Manganese Rich NMC Composite Cathodes with Cycling Friday, August 29, 2014 Renewable energy is critical for the...

  8. active capacitive voltage: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Khoman 5 Discrete Steps in the Capacitance-Voltage Characteristics of GaInNGaN Light Emitting Diode Structures Materials Science Websites Summary: Discrete Steps in the...

  9. Sharp interface and voltage conservation in the ... - Purdue University

    E-Print Network [OSTI]

    2007-07-14T23:59:59.000Z

    electrical wave is anisotropic, and cardiac tissue is made up of cells with heteroge- ... fact that voltage gain or loss due to numerical inaccuracies in the spatial ...

  10. Triple voltage dc-to-dc converter and method

    DOE Patents [OSTI]

    Su, Gui-Jia (Knoxville, TN)

    2008-08-05T23:59:59.000Z

    A circuit and method of providing three dc voltage buses and transforming power between a low voltage dc converter and a high voltage dc converter, by coupling a primary dc power circuit and a secondary dc power circuit through an isolation transformer; providing the gating signals to power semiconductor switches in the primary and secondary circuits to control power flow between the primary and secondary circuits and by controlling a phase shift between the primary voltage and the secondary voltage. The primary dc power circuit and the secondary dc power circuit each further comprising at least two tank capacitances arranged in series as a tank leg, at least two resonant switching devices arranged in series with each other and arranged in parallel with the tank leg, and at least one voltage source arranged in parallel with the tank leg and the resonant switching devices, said resonant switching devices including power semiconductor switches that are operated by gating signals. Additional embodiments having a center-tapped battery on the low voltage side and a plurality of modules on both the low voltage side and the high voltage side are also disclosed for the purpose of reducing ripple current and for reducing the size of the components.

  11. auxiliary voltage converter: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Voltage Switching inverter working at 20 kHz and an output stage (high frequency transformers, Schottky rectifi ers and output filter... Jrgensen, H E; Dupaquier, A;...

  12. Electrochemical Characterization of Voltage Fade in LMR-NMC cells

    Broader source: Energy.gov (indexed) [DOE]

    the extent of Voltage Fade December 2012 * Establish baseline data on standard materials to facilitate comparison of various datasets March 2013 * Obtain data to determine...

  13. Electrochemical Characterization of Voltage Fade in LMR-NMC cells...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Electrochemical Characterization of Voltage Fade in LMR-NMC cells 2013 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Program Annual Merit Review and Peer...

  14. Lattice QCD input for axion cosmology

    E-Print Network [OSTI]

    Evan Berkowitz; Michael I. Buchoff; Enrico Rinaldi

    2015-05-27T23:59:59.000Z

    One intriguing BSM particle is the QCD axion, which could simultaneously provide a solution to the Strong CP problem and account for some, if not all, of the dark matter density in the universe. This particle is a pNGB of the conjectured Peccei-Quinn (PQ) symmetry of the Standard Model. Its mass and interactions are suppressed by a heavy symmetry breaking scale, $f_a$, whose value is roughly greater than $10^{9}$ GeV (or, conversely, the axion mass, $m_a$, is roughly less than $10^4\\ \\mu \\text{eV}$). The density of axions in the universe, which cannot exceed the relic dark matter density and is a quantity of great interest in axion experiments like ADMX, is a result of the early-universe interplay between cosmological evolution and the axion mass as a function of temperature. The latter quantity is proportional to the second derivative of the QCD free energy with respect to the CP-violating phase, $\\theta$. However, this quantity is generically non-perturbative and previous calculations have only employed instanton models at the high temperatures of interest (roughly 1 GeV). In this and future works, we aim to calculate the temperature-dependent axion mass at small $\\theta$ from first-principle lattice calculations, with controlled statistical and systematic errors. Once calculated, this temperature-dependent axion mass is input for the classical evolution equations of the axion density of the universe. Due to a variety of lattice systematic effects at the very high temperatures required, we perform a calculation of the leading small-$\\theta$ cumulant of the theta vacua on large volume lattices for SU(3) Yang-Mills with high statistics as a first proof of concept, before attempting a full QCD calculation in the future. From these pure glue results, the misalignment mechanism yields the axion mass bound $m_a \\geq (14.6\\pm0.1) \\ \\mu \\text{eV}$ when PQ-breaking occurs after inflation.

  15. arterial input functions: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    high-resolution detection of the arterial and venous input function through a PET Wrist Environmental Sciences and Ecology Websites Summary: model. Due to safety and...

  16. arterial input function: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    high-resolution detection of the arterial and venous input function through a PET Wrist Environmental Sciences and Ecology Websites Summary: model. Due to safety and...

  17. Possible Magmatic Input to the Dixie Valley Geothermal Field...

    Open Energy Info (EERE)

    (MT) Resistivity Surveying Jump to: navigation, search OpenEI Reference LibraryAdd to library Journal Article: Possible Magmatic Input to the Dixie Valley Geothermal Field, and...

  18. Impacts of atmospheric nutrient inputs on marine biogeochemistry

    E-Print Network [OSTI]

    Krishnamurthy, Aparna; Moore, J. Keith; Mahowald, Natalie; Luo, Chao; Zender, Charles S

    2010-01-01T23:59:59.000Z

    biomass burning, and biofuels) dominate P inputs [Olmez etburning, fossil fuels, biofuels, volcanoes, sea salts whichburning, fossil fuels, biofuels) G01006 of total P are

  19. ,"New York Natural Gas Input Supplemental Fuels (MMcf)"

    U.S. Energy Information Administration (EIA) Indexed Site

    Name","Description"," Of Series","Frequency","Latest Data for" ,"Data 1","New York Natural Gas Input Supplemental Fuels (MMcf)",1,"Annual",2013 ,"Release Date:","227...

  20. A Requirement for Significant Reduction in the Maximum BTU Input...

    Energy Savers [EERE]

    A Requirement for Significant Reduction in the Maximum BTU Input Rate of Decorative Vented Gas Fireplaces Would Impose Substantial Burdens on Manufacturers A Requirement for...

  1. Local Dynamic Reactive Power for Correction of System Voltage Problems

    SciTech Connect (OSTI)

    Kueck, John D [ORNL; Rizy, D Tom [ORNL; Li, Fangxing [ORNL; Xu, Yan [ORNL; Li, Huijuan [University of Tennessee, Knoxville (UTK); Adhikari, Sarina [ORNL; Irminger, Philip [ORNL

    2008-12-01T23:59:59.000Z

    Distribution systems are experiencing outages due to a phenomenon known as local voltage collapse. Local voltage collapse is occurring in part because modern air conditioner compressor motors are much more susceptible to stalling during a voltage dip than older motors. These motors can stall in less than 3 cycles (.05s) when a fault, such as on the sub-transmission system, causes voltage to sag to 70 to 60%. The reasons for this susceptibility are discussed in the report. During the local voltage collapse, voltages are depressed for a period of perhaps one or two minutes. There is a concern that these local events are interacting together over larger areas and may present a challenge to system reliability. An effective method of preventing local voltage collapse is the use of voltage regulation from Distributed Energy Resources (DER) that can supply or absorb reactive power. DER, when properly controlled, can provide a rapid correction to voltage dips and prevent motor stall. This report discusses the phenomenon and causes of local voltage collapse as well as the control methodology we have developed to counter voltage sag. The problem is growing because of the use of low inertia, high efficiency air conditioner (A/C) compressor motors and because the use of electric A/C is growing in use and becoming a larger percentage of system load. A method for local dynamic voltage regulation is discussed which uses reactive power injection or absorption from local DER. This method is independent, rapid, and will not interfere with conventional utility system voltage control. The results of simulations of this method are provided. The method has also been tested at the ORNL s Distributed Energy Communications and Control (DECC) Laboratory using our research inverter and synchronous condenser. These systems at the DECC Lab are interconnected to an actual distribution system, the ORNL distribution system, which is fed from TVA s 161kV sub-transmission backbone. The test results are also provided and discussed. The simulations and testing show that local voltage control from DER can prevent local voltage collapse. The results also show that the control can be provided so quickly, within 0.5 seconds, that is does not interfere with conventional utility methods.

  2. Interactive Computing 1 Input/Output and Complex Arithmetic

    E-Print Network [OSTI]

    Verschelde, Jan

    Interactive Computing 1 Input/Output and Complex Arithmetic interactive Python scripts complex Software (MCS 507 L-3) Interactive Computing 30 August 2013 1 / 33 #12;Interactive Computing 1 Input/Output and Complex Arithmetic interactive Python scripts complex arithmetic 2 Python Coding Style and pylint coding

  3. Towards Efficient Private Distributed Computation on Unbounded Input Streams

    E-Print Network [OSTI]

    /11), Cabarnit Cyber Security MAGNET Consortium, MAFAT and Deutsche Telekom Labs at BGU. #12;2 Shlomi Dolev1Towards Efficient Private Distributed Computation on Unbounded Input Streams Shlomi Dolev1 , Juan- curely and distributively perform a computation on common inputs, in such a way that even if the entire

  4. Global sensitivity analysis of computer models with functional inputs

    E-Print Network [OSTI]

    Boyer, Edmond

    -based sensitivity analysis techniques, based on the so-called Sobol's indices, when some input variables computer codes which need a preliminary metamodeling step before performing the sensitivity analysis. We). The "mean model" allows to estimate the sensi- tivity indices of each scalar input variables, while

  5. Considering Workload Input Variations in Error Coverage Estimation

    E-Print Network [OSTI]

    Karlsson, Johan

    different parts of the workload code to be executed different number of times. By using the results from in the workload input when estimating error detection coverage using fault injection are investigated. Results sequence based on results from fault injection experiments with another input sequence is presented

  6. Coordination of Multiple Non-Holonomic Agents with Input Constraints

    E-Print Network [OSTI]

    Loizou, Savvas G.

    -aircraft systems modeled as hybrid systems. With the advent of powerful formal verification tools, there has been with aircraft-like kinematic constraints. A model of a system of input-constrained non- holonomic agents by Belta et al. in [10]. In this paper, a discrete model of a system with input- constrained non

  7. An improved voltage control on large-scale power system

    SciTech Connect (OSTI)

    Vu, H.; Pruvot, P.; Launay, C.; Harmand, Y. [Electricite de France, Clamart (France). Study and Research Div.] [Electricite de France, Clamart (France). Study and Research Div.

    1996-08-01T23:59:59.000Z

    To achieve a better voltage-var control in the electric power transmission system, different facilities are used. Generators are equipped with automatic voltage regulators to cope with sudden and random changes voltage caused by natural load fluctuations or failures. Other devices like capacitors, inductors, transformers with on load tap changers are installed on the network. Faced with the evolution of the network and operating conditions, electricity utilities are more and more interested in overall and coherent control systems, automatic or not. These systems are expected to coordinate the actions of local facilities for a better voltage control (more stable and faster reaction) inside different areas of the network in case of greater voltage and var variations. They affords besides a better use of existing reactive resources. Also, installation of new devices can be avoided allowing economy of investment. With this frame of mind, EDF has designed a system called Co-ordinated Secondary Voltage Control (CSVC). It`s an automatic closed loop system with a dynamic of a few minutes. It takes into account the network conditions (topology, loads), the voltage limits and the generator operating constraints. This paper presents recent improvements which allow the CSVC to control the voltage profile and different kinds of reactive means on a large-scale power system. Furthermore, this paper presents solution to spread out investment costs over several years, considering a deployment gradually extended.

  8. Measurement of high voltage using Rutherford backscattering spectrometry

    E-Print Network [OSTI]

    Abrego, Celestino Pete

    2007-04-25T23:59:59.000Z

    A novel variation of Rutherford Backscattering Spectrometry (RBS) has been utilized to measure a high voltage collected on an aluminum target by Direct Energy Conversion. The maximum high voltage on the target was measured to be 97.5 kV +/- 2 k...

  9. A LOW-VOLTAGE TEMPERATURE-STABLE MICROMECHANICAL PIEZOELECTRIC OSCILLATOR

    E-Print Network [OSTI]

    Ayazi, Farrokh

    A LOW-VOLTAGE TEMPERATURE-STABLE MICROMECHANICAL PIEZOELECTRIC OSCILLATOR Reza Abdolvand, Hossein polarization voltages (5-20V) for operation, which complicates the design of the oscillator circuit in today reference oscillator that utilizes a temperature-stable thin- film piezoelectric-on-silicon resonator

  10. Control and Protection Cooperation Strategy for Voltage Instability

    E-Print Network [OSTI]

    Chen, Zhe

    to be transmitted in the weak linked system. On the other hand, the backup protection relays on the transmissionControl and Protection Cooperation Strategy for Voltage Instability Zhou Liu Aalborg University zli are caused by unexpected backup relay operations due to low voltage or overload state caused by post fault

  11. Voltage sensor with fiber Fabry-Perot interferometer

    E-Print Network [OSTI]

    Wann, Been-Huey

    1992-01-01T23:59:59.000Z

    INTRODUCTION. Page II RESEARCH DESCRIPTION. . . A. Optical Fiber Fabry-Perot Interferometer. . . . . B. Piezoelectricity. . C. Modulating Point in 60 Hz Voltage Measurement. . . . . . D. Temperature Control Circuit . . . . 18 . . . 26 III EXPERIMENTAL... PROCEDURES AND RESULTS. . . . . . A. Fabrication of the Optical Fiber Fabry-Perot Interferometer B. Selection of Piezoelectric Materials. C. Implementation of Temperature Control Circuit. . . . D. Experiments of Optical Fiber Voltage Sensor...

  12. Analysis of Voltage Rise Effect on Distribution Network with Distributed

    E-Print Network [OSTI]

    Pota, Himanshu Roy

    Analysis of Voltage Rise Effect on Distribution Network with Distributed Generation M. A. Mahmud.hossain@adfa.edu.au, and H.Pota@adfa.edu.au). Abstract: Connections of distributed generation (DG) in distribution networks are increasing. These connections of distributed generation cause voltage rise in the distribution network

  13. CompilerDirected Dynamic Voltage Scaling Based on Program Regions

    E-Print Network [OSTI]

    Kremer, Ulrich

    Compiler­Directed Dynamic Voltage Scaling Based on Program Regions Chung­Hsing Hsu and Ulrich using dynamic voltage scaling. The compiler identifies pro­ gram regions where the CPU can be slowed down without resulting in a significant overall performance loss. For such regions the lowest CPU

  14. Power Grid Voltage Integrity Verification Department of ECE

    E-Print Network [OSTI]

    Najm, Farid N.

    Power Grid Voltage Integrity Verification Maha Nizam Department of ECE University of Toronto devgan@magma-da.com ABSTRACT Full-chip verification requires one to check if the power grid is safe, i.e., if the voltage drop on the grid does not exceed a cer- tain threshold. The traditional simulation-based solution

  15. E-beam high voltage switching power supply

    DOE Patents [OSTI]

    Shimer, D.W.; Lange, A.C.

    1996-10-15T23:59:59.000Z

    A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 figs.

  16. E-beam high voltage switching power supply

    DOE Patents [OSTI]

    Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

    1996-01-01T23:59:59.000Z

    A high-power power supply produces a controllable, constant high voltage put under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

  17. Low-voltage gas-discharge device

    DOE Patents [OSTI]

    Kovarik, V.J.; Hershcovitch, A.; Prelec, K.

    1982-06-08T23:59:59.000Z

    An electronic device of the type wherein current flow is conducted by an ionized gas comprising a cathode of the type heated by ionic bombardment, an anode, means for maintaining a predetermined pressure in the region between the anode and the cathode and means for maintaining a field in the region is described. The field, which is preferably a combined magnetic and electric field, is oriented so that the mean distance traveled by electrons before reaching the anode is increased. Because of this increased distance traveled electrons moving to the anode will ionize a large number of gas atoms, thus reducing the voltage necessary to initiate gas breakdown. In a preferred embodiment the anode is a main hollow cathode and the cathode is a smaller igniter hollow cathode located within and coaxial with the main hollow cathode. An axial magnetic field is provided in the region between the hollow cathodes in order to facilitate gas breakdown in that region and initiate plasma discharge from the main hollow cathode.

  18. Spark-safe low-voltage detonator

    DOE Patents [OSTI]

    Lieberman, Morton L. (Albuquerque, NM)

    1989-01-01T23:59:59.000Z

    A column of explosive in a low-voltage detonator which makes it spark-safe ncludes an organic secondary explosive charge of HMX in the form of a thin pad disposed in a bore of a housing of the detonator in an ignition region of the explosive column and adjacent to an electrical ignition device at one end of the bore. The pad of secondary charge has an axial thickness within the range of twenty to thirty percent of its diameter. The explosive column also includes a first explosive charge of CP disposed in the housing bore in the ignition region of the explosive column next to the secondary charge pad on a side opposite from the ignition device. The first CP charge is loaded under sufficient pressure, 25 to 40 kpsi, to provide mechanical confinement of the pad of secondary charge and physical coupling thereof with the ignition device. The explosive column further includes a second explosive charge of CP disposed in the housing bore in a transition region of the explosive column next to the first CP charge on a side opposite from the pad of secondary charge. The second CP charge is loaded under sufficient pressure, about 10 kpsi, to allow occurrence of DDT. The first explosive CP charge has an axial thickness within the range of twenty to thirty percent of its diameter, whereas the second explosive CP charge contains a series of increments (nominally 4) each of which has an axial thickness-to-diameter ratio of one to two.

  19. Bonfire-safe low-voltage detonator

    DOE Patents [OSTI]

    Lieberman, Morton L. (Albuquerque, NM)

    1990-01-01T23:59:59.000Z

    A column of explosive in a low-voltage detonator which makes it bonfire-safe includes a first layer of an explosive charge of CP, or a primary explosive, and a second layer of a secondary organic explosive charge, such as PETN, which has a degradation temperature lower than the autoignition temperature of the CP or primary explosives. The first layer is composed of a pair of increments disposed in a bore of a housing of the detonator in an ignition region of the explosive column and adjacent to and in contact with an electrical ignition device at one end of the bore. The second layer is composed of a plurality of increments disposed in the housing bore in a transition region of the explosive column next to and in contact with the first layer on a side opposite from the ignition device. The first layer is loaded under a sufficient high pressure, 25 to 40 kpsi, to achieve ignition, whereas the second layer is loaded under a sufficient low pressure, about 10 kpsi, to allow occurrence of DDT. Each increment of the first and second layers has an axial length-to-diameter ratio of one-half.

  20. Bonfire-safe low-voltage detonator

    DOE Patents [OSTI]

    Lieberman, M.L.

    1988-07-01T23:59:59.000Z

    A column of explosive in a low-voltage detonator which makes it bonfire-safe includes a first layer of an explosive charge of CP, or a primary explosive, and a second layer of a secondary organic explosive charge, such as PETN, which has a degradation temperature lower than the autoignition temperature of the CP or primary explosives. The first layer is composed of a pair of increments disposed in a bore of a housing of the detonator in an ignition region of the explosive column and adjacent to and in contact with an electrical ignition device at one end of the bore. The second layer is composed of a plurality of increments disposed in the housing bore in a transition region of the explosive column next to and in contact with the first layer on a side opposite from the ignition device. The first layer is loaded under a sufficient high pressure, 25 to 40 kpsi, to achieve ignition, whereas the second layer is loaded under a sufficient low pressure, about 10 kpsi, to allow occurrence of DDT. Each increment of the first and second layers has an axial length-to-diameter ratio of one-half. 2 figs.

  1. Integrated, Low Voltage, DynamicallyIntegrated, Low Voltage, Dynamically Adaptive BuckAdaptive Buck--Boost ConverterBoost Converter

    E-Print Network [OSTI]

    Rincon-Mora, Gabriel A.

    Improvement in battery life Low voltage Single cell operation (Li-ion/NiCd/NiMH/Fuel Cell) Integrated frequency 1 MHz ± 20% Closed-loop bandwidth 50 kHz 1-dB step change response time 20 µsec Full-load efficiency 90 % Control signal Output voltageTpower_change Tresponse Time 1 dB Typical transient response

  2. T-623: HP Business Availability Center Input Validation Hole Permits Cross-Site Scripting Attacks

    Broader source: Energy.gov [DOE]

    The software does not properly filter HTML code from user-supplied input before displaying the input.

  3. The commercial development of water repellent coatings for high voltage transmission lines

    SciTech Connect (OSTI)

    Hunter, Scott Robert [ORNL

    2013-10-01T23:59:59.000Z

    The purpose of the Cooperative Research and Development Agreement (CRADA) between UT-Battelle, LLC and Southwire Company was to jointly develop a low cost, commercially viable, water-repellant anti-icing coating system for high voltage transmission lines. Icing of power lines and other structures caused by freezing rain events occurs annually in the United States, and leads to severe and prolonged power outages. These outages cause untold economic and personal distress for many American families and businesses. Researchers at the Department of Energy s Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee have previously developed a set of superhydrophobic coatings with remarkable anti-icing properties that could potentially be sprayed or painted onto high-tension power lines and pylons. These coatings drastically reduce ice accumulation on these structures during freezing rain events. The project involved obtaining technical input, supplies and test high voltage cables from Southwire, along with the joint development of anti-icing coating techniques, which would result in a commercial license agreement between Southwire and ORNL, and potentially other companies requiring water repellent anti-icing coatings.

  4. The commercial development of water repellent coatings for high voltage transmission lines

    SciTech Connect (OSTI)

    Hunter, S. R. [ORNL] [ORNL; Daniel, A. [Southwire Company] [Southwire Company

    2013-10-31T23:59:59.000Z

    The purpose of the Cooperative Research and Development Agreement (CRADA) between UT-Battelle, LLC and Southwire Company was to jointly develop a low cost, commercially viable, water-repellant anti-icing coating system for high voltage transmission lines. Icing of power lines and other structures caused by freezing rain events occurs annually in the United States, and leads to severe and prolonged power outages. These outages cause untold economic and personal distress for many American families and businesses. Researchers at the Department of Energy?s Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee have previously developed a set of superhydrophobic coatings with remarkable anti-icing properties that could potentially be sprayed or painted onto high-tension power lines and pylons. These coatings drastically reduce ice accumulation on these structures during freezing rain events. The project involved obtaining technical input, supplies and test high voltage cables from Southwire, along with the joint development of anti-icing coating techniques, which would result in a commercial license agreement between Southwire and ORNL, and potentially other companies requiring water repellent anti-icing coatings.

  5. High voltage dc--dc converter with dynamic voltage regulation and decoupling during load-generated arcs

    DOE Patents [OSTI]

    Shimer, D.W.; Lange, A.C.

    1995-05-23T23:59:59.000Z

    A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 Figs.

  6. High voltage dc-dc converter with dynamic voltage regulation and decoupling during load-generated arcs

    DOE Patents [OSTI]

    Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

    1995-01-01T23:59:59.000Z

    A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

  7. Panel Session: Optimization Techniques in Voltage Collapse Analysis," IEEE PES Summer Meeting, San Diego, July 14, 1998. Applications of Optimization to Voltage Collapse Analysis

    E-Print Network [OSTI]

    Cañizares, Claudio A.

    Panel Session: Optimization Techniques in Voltage Collapse Analysis," IEEE PES Summer Meeting, San Diego, July 14, 1998. Applications of Optimization to Voltage Collapse Analysis Claudio A. Ca|Thispaper describesseveralapplica- tions of optimization for voltage stability analysis VSA of power systems. Voltage stability prob

  8. Wavelength meter having single mode fiber optics multiplexed inputs

    DOE Patents [OSTI]

    Hackel, Richard P. (Livermore, CA); Paris, Robert D. (San Ramon, CA); Feldman, Mark (Pleasanton, CA)

    1993-01-01T23:59:59.000Z

    A wavelength meter having a single mode fiber optics input is disclosed. The single mode fiber enables a plurality of laser beams to be multiplexed to form a multiplexed input to the wavelength meter. The wavelength meter can provide a determination of the wavelength of any one or all of the plurality of laser beams by suitable processing. Another aspect of the present invention is that one of the laser beams could be a known reference laser having a predetermined wavelength. Hence, the improved wavelength meter can provide an on-line calibration capability with the reference laser input as one of the plurality of laser beams.

  9. Wavelength meter having single mode fiber optics multiplexed inputs

    DOE Patents [OSTI]

    Hackel, R.P.; Paris, R.D.; Feldman, M.

    1993-02-23T23:59:59.000Z

    A wavelength meter having a single mode fiber optics input is disclosed. The single mode fiber enables a plurality of laser beams to be multiplexed to form a multiplexed input to the wavelength meter. The wavelength meter can provide a determination of the wavelength of any one or all of the plurality of laser beams by suitable processing. Another aspect of the present invention is that one of the laser beams could be a known reference laser having a predetermined wavelength. Hence, the improved wavelength meter can provide an on-line calibration capability with the reference laser input as one of the plurality of laser beams.

  10. Electronic high voltage generator with a high temperature superconducting coil

    SciTech Connect (OSTI)

    Jin, J.X.; Liu, H.K.; Dou, S.X. [Univ. of Wollongong (Australia)] [and others

    1996-12-31T23:59:59.000Z

    A novel method for generating high voltages from a low voltage DC source, by using a capacitor and inductor in a R, L, C resonant circuit has been developed with the consideration of using a high temperature superconducting (HTS) coil. To generate high voltages the polarity of a low voltage battery source is reversed each half resonant cycle, the control being achieved by an electronic switch. Resistance in the circuit limits the voltages that can be built up. By replacing a copper winding inductor with another inductor which has a HTS winding, the magnitude of achievable voltages is substantially increased. A (Bi,Pb){sub 2}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10+x} multifilament HTS wire is considered in this work to make the superconducting inductor. The high voltages generated are not capable of supplying low impedance loads, however, possible applications of the generator include electrical partial discharge testing and insulation resistance testing. It could also be used as a testing method for the HTS itself with respect to the critical current and AC loss measurement.

  11. Electro-optic voltage sensor with beam splitting

    DOE Patents [OSTI]

    Woods, Gregory K. (Cornelius, OR); Renak, Todd W. (Idaho Falls, ID); Davidson, James R. (Idaho Falls, ID); Crawford, Thomas M. (Idaho Falls, ID)

    2002-01-01T23:59:59.000Z

    The invention is a miniature electro-optic voltage sensor system capable of accurate operation at high voltages without use of the dedicated voltage dividing hardware typically found in the prior art. The invention achieves voltage measurement without significant error contributions from neighboring conductors or environmental perturbations. The invention employs a transmitter, a sensor, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor. Within the sensor the beam undergoes the Pockels electro-optic effect. The electro-optic effect produces a modulation of the beam's polarization, which is in turn converted to a pair of independent conversely-amplitude-modulated signals, from which the voltage of the E-field is determined by the signal processor. The use of converse AM signals enables the signal processor to better distinguish signal from noise. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

  12. Electro-optic voltage sensor with Multiple Beam Splitting

    DOE Patents [OSTI]

    Woods, Gregory K. (Cornelius, OR); Renak, Todd W. (Idaho Falls, ID); Crawford, Thomas M. (Idaho Falls, ID); Davidson, James R. (Idaho Falls, ID)

    2000-01-01T23:59:59.000Z

    A miniature electro-optic voltage sensor system capable of accurate operation at high voltages without use of the dedicated voltage dividing hardware. The invention achieves voltage measurement without significant error contributions from neighboring conductors or environmental perturbations. The invention employs a transmitter, a sensor, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor. Within the sensor the beam undergoes the Pockels electro-optic effect. The electro-optic effect produces a modulation of the beam's polarization, which is in turn converted to a pair of independent conversely-amplitude-modulated signals, from which the voltage of the E-field is determined by the signal processor. The use of converse AM signals enables the signal processor to better distinguish signal from noise. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

  13. Spark-safe low-voltage detonator

    DOE Patents [OSTI]

    Lieberman, M.L.

    1988-07-01T23:59:59.000Z

    A column of explosive in a low-voltage detonator which makes it spark-safe includes an organic secondary explosive charge of HMX in the form of a thin pad disposed in a bore of a housing of the detonator in an ignition region of the explosive column and adjacent to an electrical ignition device at one end of the bore. The pad of secondary charge has an axial thickness within the range of twenty to thirty percent of its diameter. The explosive column also includes a first explosive charge of CP disposed in the housing bore in the ignition region of the explosive column next to the secondary charge pad on a side opposite from the ignition device. The first CP charge is loaded under sufficient pressure, 25 to 40 kpsi, to provide mechanical confinement of the pad of secondary charge and physical coupling thereof with the ignition device. The explosive column further includes a second explosive charge of CP disposed in the housing bore in a transition region of the explosive column next to the first CP charge on a side opposite from the pad of secondary charge. The second CP charge is loaded under sufficient pressure, about 10 kpsi, to allow occurrence of DDT. The first explosive CP charge has an axial thickness within the range of twenty to thirty percent of its diameter, whereas the second explosive CP charge contains a series of increments (nominally 4), each of which has an axial thickness-to-diameter ratio of one to two. 2 figs.

  14. ONTHEGO TEXT ENTRY: EVALUATING AND IMPROVING MOBILE TEXT INPUT ON

    E-Print Network [OSTI]

    Starner, Thad E.

    ON­THE­GO TEXT ENTRY: EVALUATING AND IMPROVING MOBILE TEXT INPUT ON MINI­QWERTY KEYBOARDS A Thesis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv I INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 Thesis Statement-QWERTY KEYBOARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 4.1 Blind Typing in Real

  15. Face Interface : a methodology for experimental learning of input modalities

    E-Print Network [OSTI]

    Wetzel, Jon William

    2007-01-01T23:59:59.000Z

    This thesis demonstrates that creating a system with a visual representation of the face which mirrors the user's facial gestures appears to solve problems in teaching a user to use the new input affordances of face-based ...

  16. Adaptive Distributed Parameter and Input Estimation in Plasma Tokamak Heat

    E-Print Network [OSTI]

    Boyer, Edmond

    . Keywords: Thermonuclear fusion, distributed parameter systems, input state and parameter estimation, adaptive infinite-dimensional estimation, Galerkin method 1. INTRODUCTION In a controlled thermonuclear fusion reactor, the plasma thermal diffusivity and heating energy play an important role

  17. Graphene induced bifurcation of energy levels at low input power

    E-Print Network [OSTI]

    Li, Rujiang; Lin, Shisheng; Liu, Xu; Chen, Hongsheng

    2015-01-01T23:59:59.000Z

    We study analytically the energy states in the waveguide system of graphene coated dielectric nanowire based on the explicit form of nonlinear surface conductivity of graphene. The energy levels of different plasmonic modes can be tuned by the input power at the order of a few tenths of mW. The self-focusing behavior and self-defocusing behavior are exhibited in the lower and upper bifurcation branches, respectively, which are separated by a saturation of input power. Moreover, due to the nonlinearity of graphene, the dispersion relations for different input powers evolve to an energy band which is in sharp contrast with the discrete energy level in the limit of zero power input.

  18. Comparison of wind stress algorithms, datasets and oceanic power input

    E-Print Network [OSTI]

    Yuan, Shaoyu

    2009-01-01T23:59:59.000Z

    If the ocean is in a statistically steady state, energy balance is a strong constraint, suggesting that the energy input into the world ocean is dissipated simultaneously at the same rate. Energy conservation is one of the ...

  19. ac input power: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    architecture was ... Salazar, Nathaniel Jay Tobias 2012-01-01 8 On the power of real Turing machines over binary inputs Mathematics Websites Summary: On the power of real Turing...

  20. additional power input: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    pairs of channels. Motohisa Fukuda; Ion Nechita 2012-12-07 4 On the power of real Turing machines over binary inputs Mathematics Websites Summary: On the power of real Turing...

  1. U-139: IBM Tivoli Directory Server Input Validation Flaw | Department...

    Broader source: Energy.gov (indexed) [DOE]

    can conduct cross-site scripting attacks PLATFORM: Version(s): 6.2, 6.3 ABSTRACT: The Web Admin Tool does not properly filter HTML code from user-supplied input before...

  2. anthropogenic lead inputs: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    et al. Pb Brest, Universit de 6 GEOS-CHEM ANTHROPOGENIC EMISSIONS Table 1. Inventories general features. Use of optional inventories is set in the input.geos file....

  3. Process and Intermediate Calculations User AccessInputs Outputs

    E-Print Network [OSTI]

    Process and Intermediate Calculations User AccessInputs Outputs Fire Behavior & Probability STARFire System Flow Valuation Processing Temporal Schedules Smoke · Zones · Zone impact · Emissions Fire and compare Valuation (Structured Elicit Process) 1) Value Layers: · Point (housing, cultural trees, etc

  4. Optically triggered high voltage switch network and method for switching a high voltage

    DOE Patents [OSTI]

    El-Sharkawi, Mohamed A. (Renton, WA); Andexler, George (Everett, WA); Silberkleit, Lee I. (Mountlake Terrace, WA)

    1993-01-19T23:59:59.000Z

    An optically triggered solid state switch and method for switching a high voltage electrical current. A plurality of solid state switches (350) are connected in series for controlling electrical current flow between a compensation capacitor (112) and ground in a reactive power compensator (50, 50') that monitors the voltage and current flowing through each of three distribution lines (52a, 52b and 52c), which are supplying three-phase power to one or more inductive loads. An optical transmitter (100) controlled by the reactive power compensation system produces light pulses that are conveyed over optical fibers (102) to a switch driver (110') that includes a plurality of series connected optical triger circuits (288). Each of the optical trigger circuits controls a pair of the solid state switches and includes a plurality of series connected resistors (294, 326, 330, and 334) that equalize or balance the potential across the plurality of trigger circuits. The trigger circuits are connected to one of the distribution lines through a trigger capacitor (340). In each switch driver, the light signals activate a phototransistor (300) so that an electrical current flows from one of the energy reservoir capacitors through a pulse transformer (306) in the trigger circuit, producing gate signals that turn on the pair of serially connected solid state switches (350).

  5. Analyzing the impacts of sales tax on agricultural inputs

    E-Print Network [OSTI]

    Lamar, Christina Helweg

    1992-01-01T23:59:59.000Z

    ANALYZING THE IMPACTS OF SALES TAX ON AGRICULTURAL INPUTS CHRISTINA HELWEG ~ Submitted to the Office of Graduate Studies of Texas AgtM University in partial fulSllment of the requirements for the degree of MASTER OF SCIENCE August 1992 Major... Subject: Agncultural Economics ABSTRACT Analyzing the Impacts of Sales Tax on Agricultural Inputs. (August 1992) Christina Helweg Lamar, B. S. , Texas AthM University Chair of Advisory Committee: Dr. Ronald Knutson With the increased demand...

  6. Charged-Particle Thermonuclear Reaction Rates: III. Nuclear Physics Input

    E-Print Network [OSTI]

    Christian Iliadis; Richard Longland; Art Champagne; Alain Coc

    2010-04-23T23:59:59.000Z

    The nuclear physics input used to compute the Monte Carlo reaction rates and probability density functions that are tabulated in the second paper of this series (Paper II) is presented. Specifically, we publish the input files to the Monte Carlo reaction rate code RatesMC, which is based on the formalism presented in the first paper of this series (Paper I). This data base contains overwhelmingly experimental nuclear physics information. The survey of literature for this review was concluded in November 2009.

  7. Secondary Control for Voltage Unbalance Compensation in an Islanded Microgrid

    E-Print Network [OSTI]

    Vasquez, Juan Carlos

    coupling (PCC). Unbalance compensation is achieved by proper control of distributed generators (DGs unbalance. Keywords-distributed generation; microgrid; secondary control; voltage unbalance compensation I. INTRODUCTION Distributed Generators (DGs) may be connected individually to the utility grid or be integrated

  8. Time varying voltage combustion control and diagnostics sensor

    DOE Patents [OSTI]

    Chorpening, Benjamin T. (Morgantown, WV); Thornton, Jimmy D. (Morgantown, WV); Huckaby, E. David (Morgantown, WV); Fincham, William (Fairmont, WV)

    2011-04-19T23:59:59.000Z

    A time-varying voltage is applied to an electrode, or a pair of electrodes, of a sensor installed in a fuel nozzle disposed adjacent the combustion zone of a continuous combustion system, such as of the gas turbine engine type. The time-varying voltage induces a time-varying current in the flame which is measured and used to determine flame capacitance using AC electrical circuit analysis. Flame capacitance is used to accurately determine the position of the flame from the sensor and the fuel/air ratio. The fuel and/or air flow rate (s) is/are then adjusted to provide reduced flame instability problems such as flashback, combustion dynamics and lean blowout, as well as reduced emissions. The time-varying voltage may be an alternating voltage and the time-varying current may be an alternating current.

  9. Planar LTCC transformers for high voltage flyback converters: Part II.

    SciTech Connect (OSTI)

    Schofield, Daryl (NASCENTechnology, Inc., Watertown, SD); Schare, Joshua M., Ph.D.; Slama, George (NASCENTechnology, Inc., Watertown, SD); Abel, David (NASCENTechnology, Inc., Watertown, SD)

    2009-02-01T23:59:59.000Z

    This paper is a continuation of the work presented in SAND2007-2591 'Planar LTCC Transformers for High Voltage Flyback Converters'. The designs in that SAND report were all based on a ferrite tape/dielectric paste system originally developed by NASCENTechnoloy, Inc, who collaborated in the design and manufacturing of the planar LTCC flyback converters. The output/volume requirements were targeted to DoD application for hard target/mini fuzing at around 1500 V for reasonable primary peak currents. High voltages could be obtained but with considerable higher current. Work had begun on higher voltage systems and is where this report begins. Limits in material properties and processing capabilities show that the state-of-the-art has limited our practical output voltage from such a small part volume. In other words, the technology is currently limited within the allowable funding and interest.

  10. An Adaptive Voltage Control Algorithm with Multiple Distributed Energy

    SciTech Connect (OSTI)

    Li, Huijuan [University of Tennessee, Knoxville (UTK); Li, Fangxing [ORNL; Adhikari, Sarina [ORNL; Xu, Yan [ORNL; Rizy, D Tom [ORNL; Kueck, John D [ORNL

    2009-01-01T23:59:59.000Z

    Distributed energy resources (DE) with power electronics (PE) interfaces with the right control are capable of providing reactive power related ancillary services. Voltage regulation in particular has drawn much attention. In this paper the challenges to control multiple DEs to regulate the local voltage in distribution systems is addressed and a decentralized adaptive voltage control method is proposed. The simulation results in different system conditions show that this adaptive voltage control method is capable of satisfying the fast response speed requirement without causing oscillation or instability of the system. Since this method has high tolerance to the shortage of the system parameters and can be widely adaptive to the variable operation situations of the power systems, it is very suited for the utility application.

  11. Multilevel cascade voltage source inverter with seperate DC sources

    DOE Patents [OSTI]

    Peng, Fang Zheng (Knoxville, TN); Lai, Jih-Sheng (Blacksburg, VA)

    2002-01-01T23:59:59.000Z

    A multilevel cascade voltage source inverter having separate DC sources is described herein. This inverter is applicable to high voltage, high power applications such as flexible AC transmission systems (FACTS) including static VAR generation (SVG), power line conditioning, series compensation, phase shifting and voltage balancing and fuel cell and photovoltaic utility interface systems. The M-level inverter consists of at least one phase wherein each phase has a plurality of full bridge inverters equipped with an independent DC source. This inverter develops a near sinusoidal approximation voltage waveform with only one switching per cycle as the number of levels, M, is increased. The inverter may have either single-phase or multi-phase embodiments connected in either wye or delta configurations.

  12. Stability issues in IC Low Drop Out voltage regulators

    E-Print Network [OSTI]

    Chava, Krishna Chaitanya

    2002-01-01T23:59:59.000Z

    Performance issues of IC Low Drop Out (LDO) voltage regulators, with specific reference to stability, are discussed in this thesis. Evaluation of existing frequency compensation schemes and their performances across operating loads is presented...

  13. High-voltage air-core pulse transformers

    SciTech Connect (OSTI)

    Rohwein, G. J.

    1981-01-01T23:59:59.000Z

    General types of air core pulse transformers designed for high voltage pulse generation and energy transfer applications are discussed with special emphasis on pulse charging systems which operate up to the multi-megavolt range. The design, operation, dielectric materials, and performance are described. It is concluded that high voltage air core pulse transformers are best suited to applications outside the normal ranges of conventional magnetic core transformers. In general these include charge transfer at high power levels and fast pulse generation with comparatively low energy. When properly designed and constructed, they are capable of delivering high energy transfer efficiency and have demonstrated superior high voltage endurance. The principal disadvantage of high voltage air core transformers is that they are not generally available from commercial sources. Consequently, the potential user must become thoroughly familiar with all aspects of design, fabrication and system application before he can produce a high performance transformer system. (LCL)

  14. IEEE 342 Node Low Voltage Networked Test System

    SciTech Connect (OSTI)

    Schneider, Kevin P.; Phanivong, Phillippe K.; Lacroix, Jean-Sebastian

    2014-07-31T23:59:59.000Z

    The IEEE Distribution Test Feeders provide a benchmark for new algorithms to the distribution analyses community. The low voltage network test feeder represents a moderate size urban system that is unbalanced and highly networked. This is the first distribution test feeder developed by the IEEE that contains unbalanced networked components. The 342 node Low Voltage Networked Test System includes many elements that may be found in a networked system: multiple 13.2kV primary feeders, network protectors, a 120/208V grid network, and multiple 277/480V spot networks. This paper presents a brief review of the history of low voltage networks and how they evolved into the modern systems. This paper will then present a description of the 342 Node IEEE Low Voltage Network Test System and power flow results.

  15. Design & Fabrication of a High-Voltage Photovoltaic Cell

    SciTech Connect (OSTI)

    Felder, Jennifer; /North Carolina State U. /SLAC

    2012-09-05T23:59:59.000Z

    Silicon photovoltaic (PV) cells are alternative energy sources that are important in sustainable power generation. Currently, applications of PV cells are limited by the low output voltage and somewhat low efficiency of such devices. In light of this fact, this project investigates the possibility of fabricating high-voltage PV cells on float-zone silicon wafers having output voltages ranging from 50 V to 2000 V. Three designs with different geometries of diffusion layers were simulated and compared in terms of metal coverage, recombination, built-in potential, and conduction current density. One design was then chosen and optimized to be implemented in the final device design. The results of the simulation serve as a feasibility test for the design concept and provide supportive evidence of the effectiveness of silicon PV cells as high-voltage power supplies.

  16. Unravelling the Performance Degradation Mechanisms in High-voltage...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Unravelling the Performance Degradation Mechanisms in High-voltage Lithium-ion Battery Composite Oxide Electrodes Apr 11 2014 02:00 PM - 03:00 PM Debasish Mohanty, ORNL, Oak Ridge...

  17. Voltage Dependent Charge Storage Modes and Capacity in Subnanometer Pores

    SciTech Connect (OSTI)

    Qiao, Rui [Clemson University; Meunier, V. [Rensselaer Polytechnic Institute (RPI); Huang, Jingsong [ORNL; Wu, Peng [ORNL; Sumpter, Bobby G [ORNL

    2012-01-01T23:59:59.000Z

    Using molecular dynamics simulations, we show that charge storage in subnanometer pores follows a distinct voltage-dependent behavior. Specifically, at lower voltages, charge storage is achieved by swapping co-ions in the pore with counterions in the bulk electrolyte. As voltage increases, further charge storage is due mainly to the removal of co-ions from the pore, leading to a capacitance increase. The capacitance eventually reaches a maximum when all co-ions are expelled from the pore. At even higher electrode voltages, additional charge storage is realized by counterion insertion into the pore, accompanied by a reduction of capacitance. The molecular mechanisms of these observations are elucidated and provide useful insight for optimizing energy storage based on supercapacitors.

  18. High frequency AC power converter for low voltage circuits

    E-Print Network [OSTI]

    Salazar, Nathaniel Jay Tobias

    2012-01-01T23:59:59.000Z

    This thesis presents a novel AC power delivery architecture that is suitable for VHF frequency (50-100MHz) polyphase AC/DC power conversion in low voltage integrated circuits. A complete AC power delivery architecture was ...

  19. Modeling the operating voltage of liquid metal battery cells

    E-Print Network [OSTI]

    Newhouse, Jocelyn Marie

    2014-01-01T23:59:59.000Z

    A one-dimensional, integrative model of the voltage during liquid metal battery operation has been developed to enhance the understanding of performance at the cell level. Two liquid metal batteries were studied: Mg-Sb for ...

  20. IMPACT OF DYNAMIC VOLTAGE SCALING (DVS) ON CIRCUIT OPTIMIZATION

    E-Print Network [OSTI]

    Esquit Hernandez, Carlos A.

    2010-01-16T23:59:59.000Z

    Circuit designers perform optimization procedures targeting speed and power during the design of a circuit. Gate sizing can be applied to optimize for speed, while Dual-VT and Dynamic Voltage Scaling (DVS) can be applied to optimize for leakage...

  1. IMPACT OF DYNAMIC VOLTAGE SCALING (DVS) ON CIRCUIT OPTIMIZATION 

    E-Print Network [OSTI]

    Esquit Hernandez, Carlos A.

    2010-01-16T23:59:59.000Z

    Circuit designers perform optimization procedures targeting speed and power during the design of a circuit. Gate sizing can be applied to optimize for speed, while Dual-VT and Dynamic Voltage Scaling (DVS) can be applied ...

  2. Strongly nonlinear dynamics of electrolytes in large ac voltages

    E-Print Network [OSTI]

    Hojgaard Olesen, Laurits

    We study the response of a model microelectrochemical cell to a large ac voltage of frequency comparable to the inverse cell relaxation time. To bring out the basic physics, we consider the simplest possible model of a ...

  3. Multilevel cascade voltage source inverter with seperate DC sources

    DOE Patents [OSTI]

    Peng, Fang Zheng (Oak Ridge, TN); Lai, Jih-Sheng (Knoxville, TN)

    1997-01-01T23:59:59.000Z

    A multilevel cascade voltage source inverter having separate DC sources is described herein. This inverter is applicable to high voltage, high power applications such as flexible AC transmission systems (FACTS) including static VAR generation (SVG), power line conditioning, series compensation, phase shifting and voltage balancing and fuel cell and photovoltaic utility interface systems. The M-level inverter consists of at least one phase wherein each phase has a plurality of full bridge inverters equipped with an independent DC source. This inverter develops a near sinusoidal approximation voltage waveform with only one switching per cycle as the number of levels, M, is increased. The inverter may have either single-phase or multi-phase embodiments connected in either wye or delta configurations.

  4. Multilevel cascade voltage source inverter with seperate DC sources

    DOE Patents [OSTI]

    Peng, Fang Zheng; Lai, Jih-Sheng

    2001-04-03T23:59:59.000Z

    A multilevel cascade voltage source inverter having separate DC sources is described herein. This inverter is applicable to high voltage, high power applications such as flexible AC transmission systems (FACTS) including static VAR generation (SVG), power line conditioning, series compensation, phase shifting and voltage balancing and fuel cell and photovoltaic utility interface systems. The M-level inverter consists of at least one phase wherein each phase has a plurality of full bridge inverters equipped with an independent DC source. This inverter develops a near sinusoidal approximation voltage waveform with only one switching per cycle as the number of levels, M, is increased. The inverter may have either single-phase or multi-phase embodiments connected in either wye or delta configurations.

  5. Multilevel cascade voltage source inverter with separate DC sources

    DOE Patents [OSTI]

    Peng, F.Z.; Lai, J.S.

    1997-06-24T23:59:59.000Z

    A multilevel cascade voltage source inverter having separate DC sources is described herein. This inverter is applicable to high voltage, high power applications such as flexible AC transmission systems (FACTS) including static VAR generation (SVG), power line conditioning, series compensation, phase shifting and voltage balancing and fuel cell and photovoltaic utility interface systems. The M-level inverter consists of at least one phase wherein each phase has a plurality of full bridge inverters equipped with an independent DC source. This inverter develops a near sinusoidal approximation voltage waveform with only one switching per cycle as the number of levels, M, is increased. The inverter may have either single-phase or multi-phase embodiments connected in either wye or delta configurations. 15 figs.

  6. Prediction of flashover voltage of non-ceramic insulators under contaminated conditions

    E-Print Network [OSTI]

    Prediction of flashover voltage of non-ceramic insulators under contaminated conditions S ABSTRACT This paper describes the development of a theoretical model to predict flashover voltage

  7. Measuring Helical FCG Voltage with an Electric Field Antenna

    SciTech Connect (OSTI)

    White, A D; Anderson, R A; Javedani, J B; Reisman, D B; Goerz, D A; Ferriera, A J; Speer, R D

    2011-08-01T23:59:59.000Z

    A method of measuring the voltage produced by a helical explosive flux compression generator using a remote electric field antenna is described in detail. The diagnostic has been successfully implemented on several experiments. Measured data from the diagnostic compare favorably with voltages predicted using the code CAGEN, validating our predictive modeling tools. The measured data is important to understanding generator performance, and is measured with a low-risk, minimally intrusive approach.

  8. Image-line voltage controlled oscillators and grating antennas

    E-Print Network [OSTI]

    Kirk, Alexander MacDonald

    1991-01-01T23:59:59.000Z

    IMAGE-LINE VOLTAGE CONTROLLED OSCILLATORS AND GRATING ANTENNAS A Thesis by ALEXANDER MacDONALD KIRK Submitted to the Office of Graduate Studies of Texas ABM University in partial fulfillment of the requirements for the degree of MASTER... OF SCIENCE May 1991 Major Subject: Electrical Engineering IMAGE-LINE VOLTAGE CONTROLLED OSCILLATORS AND GRATING ANTENNAS A Thesis by ALEXANDER MacDONALD KIRK Approved as to style and content by: Kai Chang (Chair of Committee) Robert D. Nevels...

  9. Sinusoidal voltage controlled oscillators using operational transconductance amplifiers

    E-Print Network [OSTI]

    Hoyle Passano, Javier Joaquin

    1985-01-01T23:59:59.000Z

    SINUSOIDAI. VOLTAGE CONTROLLED OSCILLATORS I. SING OPERATIONAL TRANSCONDUCTANCE AMPLIFIERS A Thesis JAVIFB . IOAQUIN HOYI. K I'ASSANO Suhndtted to the Graduate College ol' 'I'exes A8cM University in partial fulfillment of the requirement... for the degree of MASTER OF SCIENCE May 1985 Major Subject: Electrical Engineering SINUSOIDAL VOLTAGE CONTROLLED OSCILLATORS USING OPERATIONAI, TRANSCONDUCTANCE AMPLIFIERS A Thesis by JAVIER JOAQUIN HOYLE PASSANO Approved as to style and content by: o...

  10. Chloromethyl chlorosulfate as a voltage delay inhibitor in lithium cells

    DOE Patents [OSTI]

    Delnick, F.M.

    1993-04-13T23:59:59.000Z

    Chloromethyl chlorosulfate (CMCS) is used as a passive film growth inhibitor in electrochemical cells to minimize voltage delay and low-voltage discharge. Film growth on lithium anodes is significantly diminished when CMCS is added to SOCl[sub 2] and SO[sub 2]Cl[sub 2] electrolytes of lithium batteries. The CMCS also has the effect of extending the shelf-life of Li/SOCl[sub 2] and Li/SO[sub 2]Cl[sub 2] batteries.

  11. Chloromethyl chlorosulfate as a voltage delay inhibitor in lithium cells

    DOE Patents [OSTI]

    Delnick, Frank M. (Albuquerque, NM)

    1993-01-01T23:59:59.000Z

    Chloromethyl chlorosulfate (CMCS) is used as a passive film growth inhibitor in electrochemical cells to minimize voltage delay and low-voltage discharge. Film growth on lithium anodes is significantly diminished when CMCS is added to SOCl.sub.2 and SO.sub.2 Cl.sub.2 electrolytes of lithium batteries. The CMCS also has the effect of extending the shelf-life of Li/SOCl.sub.2 and Li/SO.sub.2 Cl.sub.2 batteries.

  12. High power impulse magnetron sputtering: Current-voltage-time characteristics indicate the onset of sustained self-sputtering

    E-Print Network [OSTI]

    Anders, Andre; Andersson, Joakim; Ehiasarian, Arutiun

    2008-01-01T23:59:59.000Z

    target voltage starts to slightly droop for higher voltages,1000 V, the actual voltage droops and shows less stability.see a large voltage droop, especially at high current). We

  13. Sensitivity of piping seismic responses to input factors

    SciTech Connect (OSTI)

    O'Connell, W.J.

    1985-05-01T23:59:59.000Z

    This report summarizes the sensitivity of peak dynamic seismic responses to input parameters. The responses have been modeled and calculated for the Zion Unit 1 plant as part of a seismic probabilistic risk assessment (PRA) performed by the US NRC Seismic Safety Margins Research Program (SSMRP). The SSMRP was supported by the US NRC Office of Nuclear Regulatory Research. Two sensitivity topics motivated the study. The first is the sensitivity of piping response to the mean value of piping damping. The second is the sensitivity of all the responses to the earthquake and model input parameters including soil, structure and piping parameters; this information is required for another study, the sensitivity of the plant system response (in terms of risk) to these dynamic input parameters and to other input factors. We evaluate the response sensitivities by performing a linear regression analysis (LRA) of the computer code SMACS. With SMACS we have a detailed model of the Zion plant and of the important dynamic processes in the soil, structures and piping systems. The qualitative results change with the location of the individual response. Different responses are in locations where the many potential influences have different effectiveness. The results give an overview of the complexity of the seismic dyanmic response of a plant. Within the diversity trends are evident in the influences of the input variables on the responses.

  14. Nonlinear quantum input-output analysis using Volterra series

    E-Print Network [OSTI]

    Jing Zhang; Yu-xi Liu; Re-Bing Wu; Kurt Jacobs; Sahin Kaya Ozdemir; Lan Yang; Tzyh-Jong Tarn; Franco Nori

    2014-08-04T23:59:59.000Z

    Quantum input-output theory plays a very important role for analyzing the dynamics of quantum systems, especially large-scale quantum networks. As an extension of the input-output formalism of Gardiner and Collet, we develop a new approach based on the quantum version of the Volterra series which can be used to analyze nonlinear quantum input-output dynamics. By this approach, we can ignore the internal dynamics of the quantum input-output system and represent the system dynamics by a series of kernel functions. This approach has the great advantage of modelling weak-nonlinear quantum networks. In our approach, the number of parameters, represented by the kernel functions, used to describe the input-output response of a weak-nonlinear quantum network, increases linearly with the scale of the quantum network, not exponentially as usual. Additionally, our approach can be used to formulate the quantum network with both nonlinear and nonconservative components, e.g., quantum amplifiers, which cannot be modelled by the existing methods, such as the Hudson-Parthasarathy model and the quantum transfer function model. We apply our general method to several examples, including Kerr cavities, optomechanical transducers, and a particular coherent feedback system with a nonlinear component and a quantum amplifier in the feedback loop. This approach provides a powerful way to the modelling and control of nonlinear quantum networks.

  15. Development of a Novel Bi-Directional Isolated Multiple-Input DC-DC Converter

    SciTech Connect (OSTI)

    Li, H.

    2005-10-24T23:59:59.000Z

    There is vital need for a compact, lightweight, and efficient energy-storage system that is both affordable and has an acceptable cycle life for the large-scale production of electric vehicles (EVs) and hybrid electric vehicles (HEVs). Most of the current research employs a battery-storage unit (BU) combined with a fuel cell (FC) stack in order to achieve the operating voltage-current point of maximum efficiency for the FC system. A system block diagram is shown in Fig.1.1. In such a conventional arrangement, the battery is sized to deliver the difference between the energy required by the traction drive and the energy supplied by the FC system. Energy requirements can increase depending on the drive cycle over which the vehicle is expected to operate. Peak-power transients result in an increase of losses and elevated temperatures which result in a decrease in the lifetime of the battery. This research will propose a novel two-input direct current (dc) dc to dc converter to interface an additional energy-storage element, an ultracapacitor (UC), which is shown in Fig.1.2. It will assist the battery during transients to reduce the peak-power requirements of the battery.

  16. Optical device with conical input and output prism faces

    DOE Patents [OSTI]

    Brunsden, Barry S. (Chicago, IL)

    1981-01-01T23:59:59.000Z

    A device for radially translating radiation in which a right circular cylinder is provided at each end thereof with conical prism faces. The faces are oppositely extending and the device may be severed in the middle and separated to allow access to the central part of the beam. Radiation entering the input end of the device is radially translated such that radiation entering the input end at the perimeter is concentrated toward the output central axis and radiation at the input central axis is dispersed toward the output perimeter. Devices are disclosed for compressing beam energy to enhance drilling techniques, for beam manipulation of optical spatial frequencies in the Fourier plane and for simplification of dark field and color contrast microscopy. Both refracting and reflecting devices are disclosed.

  17. Incorporating uncertainty in RADTRAN 6.0 input files.

    SciTech Connect (OSTI)

    Dennis, Matthew L.; Weiner, Ruth F.; Heames, Terence John (Alion Science and Technology)

    2010-02-01T23:59:59.000Z

    Uncertainty may be introduced into RADTRAN analyses by distributing input parameters. The MELCOR Uncertainty Engine (Gauntt and Erickson, 2004) has been adapted for use in RADTRAN to determine the parameter shape and minimum and maximum of the distribution, to sample on the distribution, and to create an appropriate RADTRAN batch file. Coupling input parameters is not possible in this initial application. It is recommended that the analyst be very familiar with RADTRAN and able to edit or create a RADTRAN input file using a text editor before implementing the RADTRAN Uncertainty Analysis Module. Installation of the MELCOR Uncertainty Engine is required for incorporation of uncertainty into RADTRAN. Gauntt and Erickson (2004) provides installation instructions as well as a description and user guide for the uncertainty engine.

  18. Self-consistent input-output formulation of quantum feedback

    SciTech Connect (OSTI)

    Yanagisawa, M. [Department of Engineering, The Australian National University, Canberra, ACT 0200 (Australia); Hope, J. J. [Department of Quantum Science, The Australian National University, Canberra, ACT 0200 (Australia)

    2010-12-15T23:59:59.000Z

    A simple method of analyzing quantum feedback circuits is presented. The classical analysis of feedback circuits can be generalized to apply to quantum systems by mapping the field operators of various outputs to other inputs via the standard input-output formalism. Unfortunately, this has led to unphysical results such as the violation of the Heisenberg uncertainty principle for in-loop fields. This paper shows that this general approach can be redeemed by ensuring a self-consistently Hermitian Hamiltonian. The calculations are based on a noncommutative calculus of operator derivatives. A full description of several examples of quantum linear and nonlinear feedback for optical systems is presented.

  19. ETFOD: a point model physics code with arbitrary input

    SciTech Connect (OSTI)

    Rothe, K.E.; Attenberger, S.E.

    1980-06-01T23:59:59.000Z

    ETFOD is a zero-dimensional code which solves a set of physics equations by minimization. The technique used is different than normally used, in that the input is arbitrary. The user is supplied with a set of variables from which he specifies which variables are input (unchanging). The remaining variables become the output. Presently the code is being used for ETF reactor design studies. The code was written in a manner to allow easy modificaton of equations, variables, and physics calculations. The solution technique is presented along with hints for using the code.

  20. Total Refinery Net Input of Crude Oil and Petroleum Products

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are nowTotal" (Percent) Type: Sulfur Content API GravityDakota" "Fuel, quality", 2013,Iowa"Dakota"YearProductionShaleInput Product:Input Product: Total

  1. Concept of Quasi-Capacitive Tapping of Bipolar Voltage-Controlled Oscillators

    E-Print Network [OSTI]

    Serdijn, Wouter A.

    Concept of Quasi-Capacitive Tapping of Bipolar Voltage-Controlled Oscillators Aleksandar Tasic the active part of the oscillator and the LC-tank, as proposed in this paper, the voltage swing over the tank of high- performance bipolar voltage-controlled oscillators (VCO's). As the voltage-controlled oscillators

  2. Neurocomputing 69 (2006) 10621065 Dependence of the spike-triggered average voltage on

    E-Print Network [OSTI]

    Gerstner, Wulfram

    2006-01-01T23:59:59.000Z

    .V. All rights reserved. Keywords: Spike-triggered voltage; h-current; Damped voltage oscillations 1 oscillations. The model comprises a variable v for the membrane voltage, with time-scale tv and a secondNeurocomputing 69 (2006) 1062­1065 Dependence of the spike-triggered average voltage on membrane

  3. Requirements for a Standard Test to Rate the Durability of PV Modules at System Voltage (Presentation)

    SciTech Connect (OSTI)

    Hacke, P.; Terwilliger, K.; Glick, S.; Kempe, M.; Kurtz, S.; Bennett, I.; Kloos, M.

    2011-02-01T23:59:59.000Z

    Degradation modes in photovoltaic modules under system bias voltage stress are described and classified.

  4. DATE04 SPECIAL SECTION Overhead-conscious voltage selection for dynamic

    E-Print Network [OSTI]

    Marchal, Loris

    combination with dynamic voltage scaling indispensable for energy-efficient designs in the foreseeable future

  5. Radio-Frequency Interference (RFI) From Extra-High-Voltage (EHV) Transmission Lines

    E-Print Network [OSTI]

    Ellingson, Steven W.

    -current (HVAC) transmission lines; high-voltage direct-current (HVDC) transmission lines will be addressed

  6. Voltage control in pulsed system by predict-ahead control

    DOE Patents [OSTI]

    Payne, A.N.; Watson, J.A.; Sampayan, S.E.

    1994-09-13T23:59:59.000Z

    A method and apparatus for predict-ahead pulse-to-pulse voltage control in a pulsed power supply system is disclosed. A DC power supply network is coupled to a resonant charging network via a first switch. The resonant charging network is coupled at a node to a storage capacitor. An output load is coupled to the storage capacitor via a second switch. A de-Q-ing network is coupled to the resonant charging network via a third switch. The trigger for the third switch is a derived function of the initial voltage of the power supply network, the initial voltage of the storage capacitor, and the present voltage of the storage capacitor. A first trigger closes the first switch and charges the capacitor. The third trigger is asserted according to the derived function to close the third switch. When the third switch is closed, the first switch opens and voltage on the node is regulated. The second trigger may be thereafter asserted to discharge the capacitor into the output load. 4 figs.

  7. Voltage sensing in ion channels: Mesoscale simulations of biological devices

    E-Print Network [OSTI]

    Peyser, Alexander

    2012-01-01T23:59:59.000Z

    Electrical signaling via voltage-gated ion channels depends upon the function of a voltage sensor (VS), identified with the S1-S4 domain in voltage-gated K+ channels. Here we investigate some energetic aspects of the sliding-helix model of the VS using simulations based on VS charges, linear dielectrics and whole-body motion. Model electrostatics in voltage-clamped boundary conditions are solved using a boundary element method. The statistical mechanical consequences of the electrostatic configurational energy are computed to gain insight into the sliding-helix mechanism and to predict experimentally measured ensemble properties such as gating charge displaced by an applied voltage. Those consequences and ensemble properties are investigated for two alternate S4 configurations, \\alpha- and 3(10)-helical. Both forms of VS are found to have an inherent electrostatic stability. Maximal charge displacement is limited by geometry, specifically the range of movement where S4 charges and counter-charges overlap in t...

  8. Nanosecond pulsed electric fields (nsPEFs) low cost generator design using power MOSFET and Cockcroft-Walton multiplier circuit as high voltage DC source

    SciTech Connect (OSTI)

    Sulaeman, M. Y.; Widita, R. [Department of Physics, Nuclear Physics and Biophysics Research Division, Faculty of Mathematics and Natural Science, Institut Teknologi Bandung, Bandung (Indonesia)

    2014-09-30T23:59:59.000Z

    Purpose: Non-ionizing radiation therapy for cancer using pulsed electric field with high intensity field has become an interesting field new research topic. A new method using nanosecond pulsed electric fields (nsPEFs) offers a novel means to treat cancer. Not like the conventional electroporation, nsPEFs able to create nanopores in all membranes of the cell, including membrane in cell organelles, like mitochondria and nucleus. NsPEFs will promote cell death in several cell types, including cancer cell by apoptosis mechanism. NsPEFs will use pulse with intensity of electric field higher than conventional electroporation, between 20–100 kV/cm and with shorter duration of pulse than conventional electroporation. NsPEFs requires a generator to produce high voltage pulse and to achieve high intensity electric field with proper pulse width. However, manufacturing cost for creating generator that generates a high voltage with short duration for nsPEFs purposes is highly expensive. Hence, the aim of this research is to obtain the low cost generator design that is able to produce a high voltage pulse with nanosecond width and will be used for nsPEFs purposes. Method: Cockcroft-Walton multiplier circuit will boost the input of 220 volt AC into high voltage DC around 1500 volt and it will be combined by a series of power MOSFET as a fast switch to obtain a high voltage with nanosecond pulse width. The motivation using Cockcroft-Walton multiplier is to acquire a low-cost high voltage DC generator; it will use capacitors and diodes arranged like a step. Power MOSFET connected in series is used as voltage divider to share the high voltage in order not to damage them. Results: This design is expected to acquire a low-cost generator that can achieve the high voltage pulse in amount of ?1.5 kV with falltime 3 ns and risetime 15 ns into a 50? load that will be used for nsPEFs purposes. Further detailed on the circuit design will be explained at presentation.

  9. Numerical solution of transient eddy current problems with input current intensities as boundary data

    E-Print Network [OSTI]

    RodrĂ­guez, Rodolfo

    Numerical solution of transient eddy current problems with input current intensities as boundary to solve transient eddy current problems with input current intensities as data, formulated in terms: Eddy current problems, time-dependent electromagnetic problems, input current intensities, finite

  10. PREDICTING THE TIME RESPONSE OF A BUILDING UNDER HEAT INPUT CONDITIONS FOR ACTIVE SOLAR HEATING SYSTEMS

    E-Print Network [OSTI]

    Warren, Mashuri L.

    2013-01-01T23:59:59.000Z

    OF A BUILDING UNDER HEAT INPUT CONDITIONS FOR ACTIVE SOLAROF A BUILDING UNDER HEAT INPUT CONDITIONS FOR ACTIVE SOLARbuilding to changes in heat input, and to predict room and

  11. High voltage stability performance of a gamma ray detection device

    SciTech Connect (OSTI)

    Abdullah, Nor Arymaswati; Lombigit, Lojius; Rahman, Nur Aira Abd [Technical Support Division, Malaysian Nuclear Agency, 43000 Kajang, Selangor (Malaysia)

    2014-02-12T23:59:59.000Z

    An industrial grade digital radiation survey meter device is currently being developed at Malaysian Nuclear Agency. This device used a cylindrical type Geiger Mueller (GM) which acts as a detector. GM detector operates at relatively high direct current voltages depend on the type of GM tube. This thin/thick walled cylindrical type of GM tube operates at 450-650 volts range. Proper value and stability performance of high voltage are important parameters to ensure that this device give a reliable radiation dose measurement. This paper will present an assessment of the stability and performance of the high voltage supply for radiation detector. The assessment is performed using System Identification tools box in MATLAB and mathematical statistics.

  12. Voltage Impacts of Utility-Scale Distributed Wind

    SciTech Connect (OSTI)

    Allen, A.

    2014-09-01T23:59:59.000Z

    Although most utility-scale wind turbines in the United States are added at the transmission level in large wind power plants, distributed wind power offers an alternative that could increase the overall wind power penetration without the need for additional transmission. This report examines the distribution feeder-level voltage issues that can arise when adding utility-scale wind turbines to the distribution system. Four of the Pacific Northwest National Laboratory taxonomy feeders were examined in detail to study the voltage issues associated with adding wind turbines at different distances from the sub-station. General rules relating feeder resistance up to the point of turbine interconnection to the expected maximum voltage change levels were developed. Additional analysis examined line and transformer overvoltage conditions.

  13. A study of temperature compensating circuits for voltage references which use negative temperature coefficient zener diodes

    E-Print Network [OSTI]

    Coleman, Spencer Delano

    1961-01-01T23:59:59.000Z

    Character- istics in Breakdown Region . 13 3f. 1N 751 Zener Diode Voltage vs Current Character- istics in Breakdown Region . 14 3g, lN752 Zener Diode Voltage vs Current Character- istics in Breakdown Region 15 4a. 1N746 Zener Diode Ambient Temperature... vs Voltage Characteristics in Breakdown Region. . . . . . . . . . 16 4b. IN747 Zener Diode Ambient Temperature vs Voltage Characteristics in Breakdown Region. . . . . . . . . . 17 4c. 1N748 Zener Diode Ambient Temperature vs Voltage...

  14. Optimal linear control systems with input derivative constraints

    E-Print Network [OSTI]

    Moore, John Barratt

    . Optimal linear control systems with input derivative constraints J. B. Moore, Ph. D., and Prof. B-loss-function minimisation problem is linear. The "paper applies the results of this optimal control theory to a class of performance desired. For linear, finite-dimensional, completely controllable systems, Kalmanl has shown

  15. Gaussian Process Training with Input Noise Andrew McHutchon

    E-Print Network [OSTI]

    Edinburgh, University of

    University Cambridge, CB2 1PZ ajm257@cam.ac.uk Carl Edward Rasmussen Department of Engineering Cambridge University Cambridge, CB2 1PZ cer54@cam.ac.uk Abstract In standard Gaussian Process regression input intuitive sense: for example, an application in Rasmussen and Williams (2006) [1] is that of modelling CO2

  16. Power Control for Discrete-Input Block-Fading Channels

    E-Print Network [OSTI]

    Guillén i Fàbregas, Albert

    . K. Rasmussen CUED / F-INFENG / TR 582 August 2007 #12;#12;1 Power Control for Discrete-Input Block-Fading Channels Khoa D. Nguyen, Albert Guill´en i F`abregas and Lars K. Rasmussen Abstract We consider power systems employing orthogonal frequency division multiplexing. K. D. Nguyen and L. K. Rasmussen

  17. Input Design for Nonlinear Stochastic Dynamic Systems -A Particle Filter

    E-Print Network [OSTI]

    Schön, Thomas

    Input Design for Nonlinear Stochastic Dynamic Systems - A Particle Filter Approach R. Bhushan in nonlinear stochastic dynamic systems. The approach relies on minimizing a function of the covariance]). There has also been work done on obtaining finite sam- ple covariance estimates (Weyer et al. [1999], Weyer

  18. CO2 enrichment increases carbon and nitrogen input from

    E-Print Network [OSTI]

    CO2 enrichment increases carbon and nitrogen input from fine roots in a deciduous forest Colleen2 Ecological Society of America, 2008 #12;#12;#12;#12;#12;+ [CO2] #12;+ Net primary production + [CO2] #12;+ Net primary production + [CO2] + C and N storage in biomass #12;+ Net primary production

  19. CHARACTERIZATION OF VIBRATIONINDUCED IMAGE DEFECTS IN INPUT SCANNERS

    E-Print Network [OSTI]

    Wolberg, George

    ) by dynamic errors of gears, timing bets, and motors, and indirectly by structural vibrations induced by gearsCHARACTERIZATION OF VIBRATION­INDUCED IMAGE DEFECTS IN INPUT SCANNERS Robert P. Loce George Wolberg. Keywords: image defects, digital documents, scanned documents, vibrations, motion quality 1. INTRODUCTION

  20. Power Control for Crossbar-based Input-Queued Switches

    E-Print Network [OSTI]

    , if f is the maximum digital signal frequency, the power consumption of a CMOS device is proportional number of data simultaneously flowing across the switching fabric. Thermal power dissipation is becoming1 Power Control for Crossbar-based Input-Queued Switches Andrea Bianco, Paolo Giaccone, Guido

  1. FULL FUEL CYCLE ASSESSMENT WELL TO WHEELS ENERGY INPUTS,

    E-Print Network [OSTI]

    FULL FUEL CYCLE ASSESSMENT WELL TO WHEELS ENERGY INPUTS, EMISSIONS, AND WATER IMPACTS Preparation for the AB 1007 (Pavley) Alternative Transportation Fuels Plan Proceeding Prepared For: California Energy, Project Manager Ray Tuvell, Manager EMERGING FUELS & TECHNOLOGY OFFICE Rosella Shapiro, Deputy Director

  2. FULL FUEL CYCLE ASSESSMENT WELL TO TANK ENERGY INPUTS,

    E-Print Network [OSTI]

    FULL FUEL CYCLE ASSESSMENT WELL TO TANK ENERGY INPUTS, EMISSIONS, AND WATER IMPACTS Prepared For Manager McKinley Addy, Project Manager Ray Tuvell, Manager EMERGING FUELS & TECHNOLOGY OFFICE Rosella Shapiro, Deputy Director FUELS AND TRANSPORTATION DIVISION B.B Blevins Executive Director DISCLAIMER

  3. U-050: Adobe Flex SDK Input Validation Flaw Permits Cross-Site Scripting Attacks

    Broader source: Energy.gov [DOE]

    Flex applications created using the Flex SDK may not properly filter HTML code from user-supplied input before displaying the input.

  4. DOE Seeks Public Input on an Integrated, Interagency Pre-Application...

    Energy Savers [EERE]

    Seeks Public Input on an Integrated, Interagency Pre-Application Process for Transmission Authorizations DOE Seeks Public Input on an Integrated, Interagency Pre-Application...

  5. Chapter 24: Alternating-Current Circuits 2. The voltage in the European wall socket oscillates between the positive and negative peak voltages, resulting in an rms

    E-Print Network [OSTI]

    Kioussis, Nicholas

    1 Chapter 24: Alternating-Current Circuits 2. The voltage in the European wall socket oscillates 240 V 340 VV V 6. A light bulb dissipates power as the voltage oscillates across its filament.0 V 1.32 A 15.2 V I X 13. An oscillating voltage drives an alternating current through a capacitor

  6. Low-voltage ultra-low-poweranalog IC design -djmamic translinearcircuits 1.3.1 1.3 Low-voltage ultra-low-power analog IC design

    E-Print Network [OSTI]

    Serdijn, Wouter A.

    Low-voltage ultra-low-poweranalog IC design -djmamic translinearcircuits 1.3.1 1.3 Low-voltage ultra-low-power analog IC design -dynamic translinear circuits 0 (rg G x m .- E . . . . . a r, a" P, 44' s" +N m - _ c o3 #12;Low-voltage ultra-low-power analog IC design -dynamic translinear circuits I

  7. High voltage switch triggered by a laser-photocathode subsystem

    DOE Patents [OSTI]

    Chen, Ping; Lundquist, Martin L.; Yu, David U. L.

    2013-01-08T23:59:59.000Z

    A spark gap switch for controlling the output of a high voltage pulse from a high voltage source, for example, a capacitor bank or a pulse forming network, to an external load such as a high gradient electron gun, laser, pulsed power accelerator or wide band radar. The combination of a UV laser and a high vacuum quartz cell, in which a photocathode and an anode are installed, is utilized as triggering devices to switch the spark gap from a non-conducting state to a conducting state with low delay and low jitter.

  8. Effects of Distributed Energy Resources on Conservation Voltage Reduction (CVR)

    SciTech Connect (OSTI)

    Singh, Ruchi; Tuffner, Francis K.; Fuller, Jason C.; Schneider, Kevin P.

    2011-10-10T23:59:59.000Z

    Conservation Voltage Reduction (CVR) is one of the cheapest technologies which can be intelligently leveraged to provide considerable energy savings. The addition of renewables in the form of distributed resources can affect the entire power system, but more importantly, affects the traditional substation control schemes at the distribution level. This paper looks at the effect on energy consumption, peak load reduction, and voltage profile changes due to the addition of distributed generation in a distribution feeder using combinations of volt var control. An IEEE 13-node system is used to simulate the various cases. Energy savings and peak load reduction for different simulation scenarios are compared.

  9. Do not exceed the operating input power, voltage, and current level and signal type appropriate for the instrument being used, refer to

    E-Print Network [OSTI]

    Anlage, Steven

    's Declaration ACOUSTIC NOISE EMISSION LpA is POLLUTION DEGREE 2, INDOOR USE product. This equipment is tested with stand-alone condition

  10. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, VOL. 33, NO. 5, SEPTEMBER/OCTOBER 1997 1203 Design of a Low-Input-Voltage Converter

    E-Print Network [OSTI]

    Bornemann, Jens

    of a thermoelectric generator (TEG). A design of a self-starting dc­dc converter is developed and optimized for very, an independent and reliable power source is needed. One solution is to use a thermoelectric generator (TEG the application, a large array of high-performance TEG's would be needed. With a single high-performance module

  11. Way to reduce arc voltage losses in hybrid thermionic converters

    SciTech Connect (OSTI)

    Tskhakaya, V.K.; Yarygin, V.I.

    1982-03-01T23:59:59.000Z

    Experimental results are reported concerning the output and emission characteristics of the arc and hybrid regimes in a plane-parallel thermionic converter with Pt--Zr--O electrode pair. It is shown that arc voltage losses can be reduced to values below those obtainable in ordinary arc thermionic converters.

  12. Standby Voltage Scaling for Reduced Power B. Calhoun, A. Chandrakasan

    E-Print Network [OSTI]

    Calhoun, Benton H.

    Engineering Massachusetts Institute of Technology, Cambridge, MA Abstract Lowering VDD during standby mode leakage, gate leakage, GIDL, and forward biased diode leak- age[2]. At the 0.13 m technology node to pinch in the rail voltages during standby[5]. The quantity and sizes of the devices used in the diode

  13. Current isolating epitaxial buffer layers for high voltage photodiode array

    DOE Patents [OSTI]

    Morse, Jeffrey D. (Martinez, CA); Cooper, Gregory A. (Pleasant Hill, CA)

    2002-01-01T23:59:59.000Z

    An array of photodiodes in series on a common semi-insulating substrate has a non-conductive buffer layer between the photodiodes and the semi-insulating substrate. The buffer layer reduces current injection leakage between the photodiodes of the array and allows optical energy to be converted to high voltage electrical energy.

  14. Power Management Unit A digitalized Embedded Linear Voltage Regulator for

    E-Print Network [OSTI]

    Wichmann, Felix

    Climate Control Cooling FAN Park Distance Control Adaptive Cruise Control Night Vision Blindspot Detection cost More expensive mask cost More sensitive to radiation Higher leakage current Lower voltage headroom) System CostsSystem Costs Si-Area, Test Time, Package (# of pins) Development Cost/ Time to market

  15. THREE DIMENSIONAL VISUALIZATIONS FOR POWER SYSTEM CONTINGENCY ANALYSIS VOLTAGE DATA

    E-Print Network [OSTI]

    that the power systems are now often operated closer to their limits to maximum transmission system utilizationTHREE DIMENSIONAL VISUALIZATIONS FOR POWER SYSTEM CONTINGENCY ANALYSIS VOLTAGE DATA Y. Sun IEEE security assessment is critical for detecting underlying problems in a power system. More frequent CA

  16. Enhanced Archaerhodopsin Fluorescent Protein Voltage Yiyang Gong1,2*

    E-Print Network [OSTI]

    Ferrari, Silvia

    Enhanced Archaerhodopsin Fluorescent Protein Voltage Indicators Yiyang Gong1,2* , Jin Zhong Li1 by nearly three-fold in comparison to Arch-D95N. Citation: Gong Y, Li JZ, Schnitzer MJ (2013) Enhanced; Published June 19, 2013 Copyright: © 2013 Gong et al. This is an open-access article distributed under

  17. Topical Review Voltage Dependence of the Na/K Pump

    E-Print Network [OSTI]

    Gadsby, David

    Topical Review Voltage Dependence of the Na/K Pump R.F. Rakowski1 , D.C. Gadsby2 , P. De Weer3 1, Philadelphia, PA 19104, USA Received: 2 August 1996/Revised: 13 September 1996 Introduction Whether Na/K pump & Rakowski, 1988). While it follows from first principles that the rate of net forward Na/K pumping must

  18. Electrodic voltages accompanying stimulated bioremediation of a uraniumcontaminated aquifer

    E-Print Network [OSTI]

    Hubbard, Susan

    the accumulation of dissolved sulfide and the removal of uranium from groundwater. The anomalies persisted for 45. Within 10 days of the voltage decrease, uranium concentrations rebounded from 0.2 to 0.8 mM, a level of bioreduced contaminants, such as uranium. Citation: Williams, K. H., A. L. N'Guessan, J. Druhan, P. E. Long

  19. Voltage Sequence Control Based High-Current Rectifier System

    E-Print Network [OSTI]

    Paderborn, Universität

    of transformer. A passive filter is added at the primary side to achieve power factor improvement over the range of output voltage. This scheme is optimized to determine optimum turns ratio of the transformer and optimum not enforce unity power factor operation and guidelines provided by harmonic standards such as IEEE-519

  20. Ultra-compact Marx-type high-voltage generator

    DOE Patents [OSTI]

    Goerz, David A. (Brentwood, CA); Wilson, Michael J. (Modesto, CA)

    2000-01-01T23:59:59.000Z

    An ultra-compact Marx-type high-voltage generator includes individual high-performance components that are closely coupled and integrated into an extremely compact assembly. In one embodiment, a repetitively-switched, ultra-compact Marx generator includes low-profile, annular-shaped, high-voltage, ceramic capacitors with contoured edges and coplanar extended electrodes used for primary energy storage; low-profile, low-inductance, high-voltage, pressurized gas switches with compact gas envelopes suitably designed to be integrated with the annular capacitors; feed-forward, high-voltage, ceramic capacitors attached across successive switch-capacitor-switch stages to couple the necessary energy forward to sufficiently overvoltage the spark gap of the next in-line switch; optimally shaped electrodes and insulator surfaces to reduce electric field stresses in the weakest regions where dissimilar materials meet, and to spread the fields more evenly throughout the dielectric materials, allowing them to operate closer to their intrinsic breakdown levels; and uses manufacturing and assembly methods to integrate the capacitors and switches into stages that can be arranged into a low-profile Marx generator.

  1. Hierarchical Control Scheme for Voltage Unbalance Compensation in Islanded Microgrids

    E-Print Network [OSTI]

    Vasquez, Juan Carlos

    Hierarchical Control Scheme for Voltage Unbalance Compensation in Islanded Microgrids Mehdi@et.aau.dk Abstract-- The concept of microgrid hierarchical control is presented, recently. In this paper, a hierarchical scheme which includes primary and secondary control levels is proposed for islanded microgrids

  2. Energy Efficient Datapath Scheduling using Multiple Voltages and Dynamic Clocking

    E-Print Network [OSTI]

    Mohanty, Saraju P.

    consumption of a device has to be minimum to increase battery life, the energy-delay- product hasEnergy Efficient Datapath Scheduling using Multiple Voltages and Dynamic Clocking Saraju P. Mohanty clocking in a co-ordinated manner in order to reduce energy consumption of datapath circuits. In dynamic

  3. Smart Grid Voltage Sag Detection using Instantaneous Features Extraction

    E-Print Network [OSTI]

    Boyer, Edmond

    encountered power quality disturbances. Index Terms--Smart grid, voltage sag detection, power quality (PQ as the generation system is moved nearby the distribution level and this is achieved by using a set of micro grids grids are their availability, reliability, and profitability; in order to fulfill power demand according

  4. Energy Efficiency in Low Voltage Hall Thrusters Jerry L. Ross

    E-Print Network [OSTI]

    King, Lyon B.

    Energy Efficiency in Low Voltage Hall Thrusters Jerry L. Ross Lyon B. King Energy efficiency/s of xenon. Acceleration and current efficiencies were compared to thrust efficiency over a range of magnet coil current values of 0 A - 2.5 A. Acceleration efficiencies were obtained with a 4-grid Retarding

  5. Memory Power Management via Dynamic Voltage/Frequency Scaling

    E-Print Network [OSTI]

    McGaughey, Alan

    years. In the data center environment, thermal management and power budgeting have become significant transitions [10, 23], or scal- ing active server power proportionally to load [2]. In this paper, we focusMemory Power Management via Dynamic Voltage/Frequency Scaling Howard David, Chris Fallin§, Eugene

  6. Memory Power Management via Dynamic Voltage/Frequency Scaling

    E-Print Network [OSTI]

    Mutlu, Onur

    years. In the data center environment, thermal management and power budgeting have become significant sleep transitions [10, 23], or scal- ing active server power proportionally to load [2]. In this paperMemory Power Management via Dynamic Voltage/Frequency Scaling Howard David, Chris Fallin§, Eugene

  7. Contribution Allocation for Voltage Stability In Deregulated Power Systems

    E-Print Network [OSTI]

    Contribution Allocation for Voltage Stability In Deregulated Power Systems Garng M. Huang, Senior, stability margin I. INTRODUCTION The deregulated power system is based on transactions; each part Member, IEEE, Kun Men Abstract: With deregulation of power systems, it is of great importance to know who

  8. Field Optimization of Three Dimensional High Voltage C. Trinitis

    E-Print Network [OSTI]

    Stamatakis, Alexandros

    Field Optimization of Three Dimensional High Voltage Equipment C. Trinitis Lehrstuhl f The goal of finding an optimal electric field strength distribution for arbitrary three di­ mensional­ cal optimization algorithm. The package ob­ tained from these three components is then able

  9. High Voltage DC Transmission 1.0 Introduction

    E-Print Network [OSTI]

    McCalley, James D.

    1 High Voltage DC Transmission 1.0 Introduction HVDC has been applied in electric power systems for many years now. Figure 1 illustrates worldwide many of the HVDC applications [1]. Fig. 1 ABB provides a webpage which summarizes HVDC projects by type and capacity or by commissioning year [2]. Wikipedia [3

  10. High Voltage DC Transmission 2 1.0 Introduction

    E-Print Network [OSTI]

    McCalley, James D.

    1 High Voltage DC Transmission 2 1.0 Introduction Interconnecting HVDC within an AC system requires on use of switching devices collectively referred to in the HVDC community as valves. Valves may be non. Fig. 1 There have been three types of devices for implementing HVDC converter circuits: mercury

  11. Power flow analysis for DC voltage droop controlled DC microgrids

    E-Print Network [OSTI]

    Chaudhary, Sanjay

    loss, such as photovoltaic panels, batteries, fuel cells, LEDs, and electronic loads, DC microgrids sharing and secondary voltage regulation can now be analytically studied, and specialized optimization of the DC microgrid, in term of systematic analysis, protection coordination design, network optimization

  12. Addition and subtraction of spin pumping voltages in magnetic hybrid structures

    SciTech Connect (OSTI)

    Azevedo, A., E-mail: aac@df.ufpe.br; Alves Santos, O.; Cunha, R. O.; Rezende, S. M. [Departamento de Física, Universidade Federal de Pernambuco, 50670-901 Recife, PE (Brazil); Rodríguez-Suárez, R. [Facultad de Física, Pontificia Universidad Católica de Chile, Casilla 306, Santiago (Chile)

    2014-04-14T23:59:59.000Z

    We report an investigation of the spin pumping voltage generated in bilayers of ferromagnetic/normal metal in which the ferromagnetic layer is yttrium iron garnet or Permalloy and the normal-metal layer is Pt or Ta. We also investigated a special case in which the voltage is detected in single layer of Permalloy under ferromagnetic resonance condition. It is shown that the spin pumping voltage generated in metallic bilayers have contributions from both layers and the resulting voltage depends on the relative signs of charge currents generated by the inverse spin Hall effect. For instance, the spin pumping voltage generated in Ta has the same sign as the one generate in single layer of Permalloy, but contrary to the voltage generated in Pt. When the voltage is measured in shunted metallic bilayers, the resulting voltage can be a sum or a subtraction of the voltages generated in both layers.

  13. Clauser-Horne Bell test with imperfect random inputs

    E-Print Network [OSTI]

    Xiao Yuan; Qi Zhao; Xiongfeng Ma

    2015-05-16T23:59:59.000Z

    Bell test is one of the most important tools in quantum information science. On the one hand, it enables fundamental test for the physics laws of nature, and on the other hand, it can be also applied in varieties of device independent tasks such as quantum key distribution and random number generation. In practice, loopholes existing in experimental demonstrations of Bell tests may affect the validity of the conclusions. In this work, we focus on the randomness (freewill) loophole and investigate the randomness requirement in a well-known Bell test, the Clauser-Horne test, under various conditions. With partially random inputs, we explicitly bound the Bell value for all local hidden variable models by optimizing the classical strategy. Our result thus puts input randomness requirement on the Clauser-Horne test under varieties of practical scenarios. The employed analysis technique can be generalized to other Bell's inequalities.

  14. Microchannel cross load array with dense parallel input

    DOE Patents [OSTI]

    Swierkowski, Stefan P.

    2004-04-06T23:59:59.000Z

    An architecture or layout for microchannel arrays using T or Cross (+) loading for electrophoresis or other injection and separation chemistry that are performed in microfluidic configurations. This architecture enables a very dense layout of arrays of functionally identical shaped channels and it also solves the problem of simultaneously enabling efficient parallel shapes and biasing of the input wells, waste wells, and bias wells at the input end of the separation columns. One T load architecture uses circular holes with common rows, but not columns, which allows the flow paths for each channel to be identical in shape, using multiple mirror image pieces. Another T load architecture enables the access hole array to be formed on a biaxial, collinear grid suitable for EDM micromachining (square holes), with common rows and columns.

  15. Regression Given input data (features), predict value of a

    E-Print Network [OSTI]

    Giger, Christine

    ^ = (XX> ) 1 Xy etc. #12;! · Many relations are not linear · The complete graph Non-linear regression #12;! · Need to fit non-linear functions · example: polynomials Non-linear regression y = 6 10000 x5 82 10000 x) the dimension of the inputs · After applying z(x), we fit a plane in 3D-space Non-linear regression y = 0 + 1x

  16. Regression Given input data (features), predict value of a

    E-Print Network [OSTI]

    Giger, Christine

    · The complete graph Non-linear regression #12;· Need to fit non-linear functions · example: polynomials Non-linear of the inputs · After applying z(x), we fit a plane in 3D-space Non-linear regression y = 0 + 1x + 2x2 z(x) = 1 x x2 #12;x y x2 regression from x to y, non-linear lifting from x to z=[x x2] regression from [x x2

  17. Thorough analysis of input physics in CESAM and CLES codes

    E-Print Network [OSTI]

    Josefina Montalban; Yveline Lebreton; Andrea Miglio; Richard Scuflaire; Pierre Morel; Arlette Noels

    2008-04-14T23:59:59.000Z

    This contribution is not about the quality of the agreement between stellar models computed by CESAM and CLES codes, but more interesting, on what ESTA-Task~1 run has taught us about these codes and about the input physics they use. We also quantify the effects of different implementations of the same physics on the seismic properties of the stellar models, that in fact is the main aim of ESTA experiments.

  18. Environmental Transport Input Parameters for the Biosphere Model

    SciTech Connect (OSTI)

    M. Wasiolek

    2004-09-10T23:59:59.000Z

    This analysis report is one of the technical reports documenting the Environmental Radiation Model for Yucca Mountain, Nevada (ERMYN), a biosphere model supporting the total system performance assessment for the license application (TSPA-LA) for the geologic repository at Yucca Mountain. A graphical representation of the documentation hierarchy for the ERMYN is presented in Figure 1-1. This figure shows relationships among the reports developed for biosphere modeling and biosphere abstraction products for the TSPA-LA, as identified in the ''Technical Work Plan for Biosphere Modeling and Expert Support'' (BSC 2004 [DIRS 169573]) (TWP). This figure provides an understanding of how this report contributes to biosphere modeling in support of the license application (LA). This report is one of the five reports that develop input parameter values for the biosphere model. The ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) describes the conceptual model and the mathematical model. The input parameter reports, shown to the right of the Biosphere Model Report in Figure 1-1, contain detailed description of the model input parameters. The output of this report is used as direct input in the ''Nominal Performance Biosphere Dose Conversion Factor Analysis'' and in the ''Disruptive Event Biosphere Dose Conversion Factor Analysis'' that calculate the values of biosphere dose conversion factors (BDCFs) for the groundwater and volcanic ash exposure scenarios, respectively. The purpose of this analysis was to develop biosphere model parameter values related to radionuclide transport and accumulation in the environment. These parameters support calculations of radionuclide concentrations in the environmental media (e.g., soil, crops, animal products, and air) resulting from a given radionuclide concentration at the source of contamination (i.e., either in groundwater or in volcanic ash). The analysis was performed in accordance with the TWP (BSC 2004 [DIRS 169573]).

  19. Bubbles as tracers of heat input to cooling flows

    E-Print Network [OSTI]

    J. Binney; F. Alouani Bibi; H. Omma

    2007-01-31T23:59:59.000Z

    We examine the distribution of injected energy in three-dimensional, adaptive-grid simulations of the heating of cooling flows. We show that less than 10 percent of the injected energy goes into bubbles. Consequently, the energy input from the nucleus is underestimated by a factor of order 6 when it is taken to be given by PVgamma/(gamma-1), where P and V are the pressure and volume of the bubble, and gamma the ratio of principal specific heats.

  20. Method of validating measurement data of a process parameter from a plurality of individual sensor inputs

    DOE Patents [OSTI]

    Scarola, Kenneth (Windsor, CT); Jamison, David S. (Windsor, CT); Manazir, Richard M. (North Canton, CT); Rescorl, Robert L. (Vernon, CT); Harmon, Daryl L. (Enfield, CT)

    1998-01-01T23:59:59.000Z

    A method for generating a validated measurement of a process parameter at a point in time by using a plurality of individual sensor inputs from a scan of said sensors at said point in time. The sensor inputs from said scan are stored and a first validation pass is initiated by computing an initial average of all stored sensor inputs. Each sensor input is deviation checked by comparing each input including a preset tolerance against the initial average input. If the first deviation check is unsatisfactory, the sensor which produced the unsatisfactory input is flagged as suspect. It is then determined whether at least two of the inputs have not been flagged as suspect and are therefore considered good inputs. If two or more inputs are good, a second validation pass is initiated by computing a second average of all the good sensor inputs, and deviation checking the good inputs by comparing each good input including a present tolerance against the second average. If the second deviation check is satisfactory, the second average is displayed as the validated measurement and the suspect sensor as flagged as bad. A validation fault occurs if at least two inputs are not considered good, or if the second deviation check is not satisfactory. In the latter situation the inputs from each of all the sensors are compared against the last validated measurement and the value from the sensor input that deviates the least from the last valid measurement is displayed.

  1. A probabilistic graphical model based stochastic input model construction

    SciTech Connect (OSTI)

    Wan, Jiang [Materials Process Design and Control Laboratory, Sibley School of Mechanical and Aerospace Engineering, 101 Frank H.T. Rhodes Hall, Cornell University, Ithaca, NY 14853-3801 (United States); Zabaras, Nicholas, E-mail: nzabaras@gmail.com [Materials Process Design and Control Laboratory, Sibley School of Mechanical and Aerospace Engineering, 101 Frank H.T. Rhodes Hall, Cornell University, Ithaca, NY 14853-3801 (United States); Center for Applied Mathematics, 657 Frank H.T. Rhodes Hall, Cornell University, Ithaca, NY 14853-3801 (United States)

    2014-09-01T23:59:59.000Z

    Model reduction techniques have been widely used in modeling of high-dimensional stochastic input in uncertainty quantification tasks. However, the probabilistic modeling of random variables projected into reduced-order spaces presents a number of computational challenges. Due to the curse of dimensionality, the underlying dependence relationships between these random variables are difficult to capture. In this work, a probabilistic graphical model based approach is employed to learn the dependence by running a number of conditional independence tests using observation data. Thus a probabilistic model of the joint PDF is obtained and the PDF is factorized into a set of conditional distributions based on the dependence structure of the variables. The estimation of the joint PDF from data is then transformed to estimating conditional distributions under reduced dimensions. To improve the computational efficiency, a polynomial chaos expansion is further applied to represent the random field in terms of a set of standard random variables. This technique is combined with both linear and nonlinear model reduction methods. Numerical examples are presented to demonstrate the accuracy and efficiency of the probabilistic graphical model based stochastic input models. - Highlights: • Data-driven stochastic input models without the assumption of independence of the reduced random variables. • The problem is transformed to a Bayesian network structure learning problem. • Examples are given in flows in random media.

  2. Voltage/Pitch Control for Maximization and Regulation of Active/Reactive Powers in Wind Turbines with Uncertainties

    E-Print Network [OSTI]

    Guo, Yi; Jiang, John N; Tang, Choon Yik; Ramakumar, Rama G

    2010-01-01T23:59:59.000Z

    This paper addresses the problem of controlling a variable-speed wind turbine with a Doubly Fed Induction Generator (DFIG), modeled as an electromechanically-coupled nonlinear system with rotor voltages and blade pitch angle as its inputs, active and reactive powers as its outputs, and most of the aerodynamic and mechanical parameters as its uncertainties. Using a blend of linear and nonlinear control strategies (including feedback linearization, pole placement, uncertainty estimation, and gradient-based potential function minimization) as well as time-scale separation in the dynamics, we develop a controller that is capable of maximizing the active power in the Maximum Power Tracking (MPT) mode, regulating the active power in the Power Regulation (PR) mode, seamlessly switching between the two modes, and simultaneously adjusting the reactive power to achieve a desired power factor. The controller consists of four cascaded components, uses realistic feedback signals, and operates without knowledge of the C_p-...

  3. Evaluation of severe accident risks: Quantification of major input parameters: MAACS (MELCOR Accident Consequence Code System) input

    SciTech Connect (OSTI)

    Sprung, J.L.; Jow, H-N (Sandia National Labs., Albuquerque, NM (USA)) [Sandia National Labs., Albuquerque, NM (USA); Rollstin, J.A. (GRAM, Inc., Albuquerque, NM (USA)) [GRAM, Inc., Albuquerque, NM (USA); Helton, J.C. (Arizona State Univ., Tempe, AZ (USA)) [Arizona State Univ., Tempe, AZ (USA)

    1990-12-01T23:59:59.000Z

    Estimation of offsite accident consequences is the customary final step in a probabilistic assessment of the risks of severe nuclear reactor accidents. Recently, the Nuclear Regulatory Commission reassessed the risks of severe accidents at five US power reactors (NUREG-1150). Offsite accident consequences for NUREG-1150 source terms were estimated using the MELCOR Accident Consequence Code System (MACCS). Before these calculations were performed, most MACCS input parameters were reviewed, and for each parameter reviewed, a best-estimate value was recommended. This report presents the results of these reviews. Specifically, recommended values and the basis for their selection are presented for MACCS atmospheric and biospheric transport, emergency response, food pathway, and economic input parameters. Dose conversion factors and health effect parameters are not reviewed in this report. 134 refs., 15 figs., 110 tabs.

  4. Interline photovoltaic (I-PV) power plants for voltage unbalance compensation

    E-Print Network [OSTI]

    Moawwad, Ahmed

    This paper proposes a stationary-frame control method for voltage unbalance compensation using Interline Photovoltaic (I-PV) power system. I-PV power systems are controlled to compensate voltage unbalance autonomously. The ...

  5. Novel techniques for fault location, voltage profile calculation and visualization of transients

    E-Print Network [OSTI]

    Evrenosoglu, Cansin Yaman

    2009-05-15T23:59:59.000Z

    techniques of voltage profiles along transmission lines. A simple yet effective approach to accurately and rapidly obtain the voltage profile along a transmission line during fault transients is presented. The objective of the presented method is to eliminate...

  6. A low-voltage zero-crossing-based delta-sigma analog-to-digital converter

    E-Print Network [OSTI]

    Guyton, Matthew C. (Matthew Christopher)

    2010-01-01T23:59:59.000Z

    A zero-crossing-based (ZCB) switched-capacitor technique is presented for operation under low power supply voltages without gate boosting. Voltage ramp generators maintain common-mode level at each integrator output. ...

  7. Dynamic photorefractivity guided by single-pulse voltage

    SciTech Connect (OSTI)

    Agashkov, A. V., E-mail: agashkov@inel.bas.net.by; Kovalev, A. A. [National Academy of Sciences of Belarus, Institute of Electronics (Belarus); Parka, J. [Military University of Technology, Institute of Applied Physics (Poland)

    2008-03-15T23:59:59.000Z

    The dynamic photorefractivity in a cell with photoconducting orienting layers, filled with a nematic liquid crystal (LC) 6CHBT and a mixture of anthraquinone dyes AD1 and AD2, has been investigated. The single-pulse mode, in which the polarity and amplitude of a dc electric field applied to an LC cell are switched for a fixed time interval, has been used. The scheme of dynamic self-diffraction of low-power laser beams was used in the experiment. The dependences of the width and intensity of diffraction pulses on the bias and switching voltages have been investigated. It is established that the width and intensity of the diffraction pulse arising after initial voltage recovery depends also on the switching pulse width. At the optimal width of the control pulse, the diffraction efficiency increases by two orders of magnitude.

  8. Analysis of Solar Cell Quality Using Voltage Metrics: Preprint

    SciTech Connect (OSTI)

    Toberer, E. S.; Tamboli, A. C.; Steiner, M.; Kurtz, S.

    2012-06-01T23:59:59.000Z

    The highest efficiency solar cells provide both excellent voltage and current. Of these, the open-circuit voltage (Voc) is more frequently viewed as an indicator of the material quality. However, since the Voc also depends on the band gap of the material, the difference between the band gap and the Voc is a better metric for comparing material quality of unlike materials. To take this one step further, since Voc also depends on the shape of the absorption edge, we propose to use the ultimate metric: the difference between the measured Voc and the Voc calculated from the external quantum efficiency using a detailed balance approach. This metric is less sensitive to changes in cell design and definition of band gap. The paper defines how to implement this metric and demonstrates how it can be useful in tracking improvements in Voc, especially as Voc approaches its theoretical maximum.

  9. Evaluation of Conservation Voltage Reduction (CVR) on a National Level

    SciTech Connect (OSTI)

    Schneider, Kevin P.; Fuller, Jason C.; Tuffner, Francis K.; Singh, Ruchi

    2010-09-29T23:59:59.000Z

    Conservation Voltage Reduction (CVR) is a reduction of energy consumption resulting from a reduction of feeder voltage. While there have been numerous CVR systems deployed in North America there has been little substantive analytic analysis of the effect; the majority of the published results are based on empirical field measurements. Since these results are based on empirical measurements it is difficult to extrapolate how this technology will behave on the various types of distribution feeders found throughout the nation. This report has utilized the Taxonomy of Prototypical feeder developed under the Modern Grid Initiative (MGI), now the Modern Grid Strategy (MGS), in order to estimate the benefits of CVR on multiple distribution feeder types. This information will then be used to determine an estimate of the national benefits of a wide scale deployment of CVR.

  10. Inhalation Exposure Input Parameters for the Biosphere Model

    SciTech Connect (OSTI)

    M. Wasiolek

    2006-06-05T23:59:59.000Z

    This analysis is one of the technical reports that support the Environmental Radiation Model for Yucca Mountain, Nevada (ERMYN), referred to in this report as the biosphere model. ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) describes in detail the conceptual model as well as the mathematical model and its input parameters. This report documents development of input parameters for the biosphere model that are related to atmospheric mass loading and supports the use of the model to develop biosphere dose conversion factors (BDCFs). The biosphere model is one of a series of process models supporting the total system performance assessment (TSPA) for a Yucca Mountain repository. ''Inhalation Exposure Input Parameters for the Biosphere Model'' is one of five reports that develop input parameters for the biosphere model. A graphical representation of the documentation hierarchy for the biosphere model is presented in Figure 1-1 (based on BSC 2006 [DIRS 176938]). This figure shows the interrelationships among the products (i.e., analysis and model reports) developed for biosphere modeling and how this analysis report contributes to biosphere modeling. This analysis report defines and justifies values of atmospheric mass loading for the biosphere model. Mass loading is the total mass concentration of resuspended particles (e.g., dust, ash) in a volume of air. Mass loading values are used in the air submodel of the biosphere model to calculate concentrations of radionuclides in air inhaled by a receptor and concentrations in air surrounding crops. Concentrations in air to which the receptor is exposed are then used in the inhalation submodel to calculate the dose contribution to the receptor from inhalation of contaminated airborne particles. Concentrations in air surrounding plants are used in the plant submodel to calculate the concentrations of radionuclides in foodstuffs contributed from uptake by foliar interception. This report is concerned primarily with the physical attributes of airborne particulate matter, such as the airborne concentrations of particles and their sizes. The conditions of receptor exposure (duration of exposure in various microenvironments), breathing rates, and dosimetry of inhaled particulates are discussed in more detail in ''Characteristics of the Receptor for the Biosphere Model'' (BSC 2005 [DIRS 172827]).

  11. Characterization of industrial process waste heat and input heat streams

    SciTech Connect (OSTI)

    Wilfert, G.L.; Huber, H.B.; Dodge, R.E.; Garrett-Price, B.A.; Fassbender, L.L.; Griffin, E.A.; Brown, D.R.; Moore, N.L.

    1984-05-01T23:59:59.000Z

    The nature and extent of industrial waste heat associated with the manufacturing sector of the US economy are identified. Industry energy information is reviewed and the energy content in waste heat streams emanating from 108 energy-intensive industrial processes is estimated. Generic types of process equipment are identified and the energy content in gaseous, liquid, and steam waste streams emanating from this equipment is evaluated. Matchups between the energy content of waste heat streams and candidate uses are identified. The resultant matrix identifies 256 source/sink (waste heat/candidate input heat) temperature combinations. (MHR)

  12. Analyzing the impacts of sales tax on agricultural inputs 

    E-Print Network [OSTI]

    Lamar, Christina Helweg

    1992-01-01T23:59:59.000Z

    the needed revenue. Of the options analyzed, the imposition of a sales tax on previously exempted agricultural inputs was introduced. The purposes of this study were to estimate the impact of the loss of the saks tax exemption relative to a state income... budget shortfall in the 1992-93 biennium for the first time in its history. This situation caused legislators to consider possil&le options to raise the needed revenue. Of the options analyzed, the imposition of a sales tax on previously exempted...

  13. Refinery & Blenders Net Input of Crude Oil

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghurajiConventionalMississippi"site.1 Relative Standard Errors for Table 1.1;"21 andNov-14Input

  14. Connecticut Natural Gas Input Supplemental Fuels (Million Cubic Feet)

    Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40Coal Stocks at CommercialDecadeReservesYear21Company LevelInput Supplemental

  15. Delaware Natural Gas Input Supplemental Fuels (Million Cubic Feet)

    Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40Coal Stocks at CommercialDecadeReservesYear21CompanySFoot) Year JanYearInput

  16. Florida Natural Gas Input Supplemental Fuels (Million Cubic Feet)

    Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40Coal Stocks at1,066,688Electricity UseFoot) Year Jan Feb Mar AprYear JanInput

  17. Hawaii Natural Gas Input Supplemental Fuels (Million Cubic Feet)

    Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40Coal Stocks at1,066,688ElectricityLess than 200Decade Year-0Year Jan Feb MarInput

  18. Iowa Natural Gas Input Supplemental Fuels (Million Cubic Feet)

    Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40Coal Stocks at1,066,688ElectricityLessApril 2015Year JanFoot) YearYearInput

  19. New Hampshire Natural Gas Input Supplemental Fuels (Million Cubic Feet)

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for On-Highway4,1,50022,3,,,,6,1,9,1,50022,3,,,,6,1,Decade1 Source: Office of(Millionthrough,Cubic Foot) DecadeYear JanInput

  20. New York Natural Gas Input Supplemental Fuels (Million Cubic Feet)

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for On-Highway4,1,50022,3,,,,6,1,9,1,50022,3,,,,6,1,Decade1 Source: Office(Billion CubicProductionFoot)Input Supplemental

  1. North Carolina Natural Gas Input Supplemental Fuels (Million Cubic Feet)

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for On-Highway4,1,50022,3,,,,6,1,9,1,50022,3,,,,6,1,Decade1 Source: Office(BillionYear Jan Feb Mar Apr May1.878Input Supplemental

  2. North Dakota Natural Gas Input Supplemental Fuels (Million Cubic Feet)

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for On-Highway4,1,50022,3,,,,6,1,9,1,50022,3,,,,6,1,Decade1 Source: Office(BillionYear Jan Feb Mar AprYearof OthersYearInput

  3. Rhode Island Natural Gas Input Supplemental Fuels (Million Cubic Feet)

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for On-Highway4,1,50022,3,,,,6,1,9,1,50022,3,,,,6,1,Decade1 Source:Additions to Capacity ForYear Jan Feb Mar Apr May Jun JulInput

  4. Wisconsin Natural Gas Input Supplemental Fuels (Million Cubic Feet)

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5 Tables July 1996 Energy Information Administration Office ofthroughYear JanYearFuel5,266 6,090 7,16354,828Feet) DecadeDecadeInput

  5. Arkansas Natural Gas Input Supplemental Fuels (Million Cubic Feet)

    Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40Coal Stocks at CommercialDecade Year-0 Year-1Year% ofInput Supplemental Fuels

  6. Table 3. U.S. Inputs to biodiesel production

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro IndustriesTownDells,1Stocks Nov-14Total Delivered Residentialtight oilU.S. Inputs to

  7. Massachusetts Natural Gas Input Supplemental Fuels (Million Cubic Feet)

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for On-Highway4,1,50022,3,,,,6,1,9,1,50022,3,,,,6,1,Decade EnergyTennesseeYearUndergroundCubic Feet) Year Jan Feb MarInput

  8. Minnesota Natural Gas Input Supplemental Fuels (Million Cubic Feet)

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for On-Highway4,1,50022,3,,,,6,1,9,1,50022,3,,,,6,1,Decade1 Source: Office of Fossil Energy, U.S. Department2Imports (NoYearInput

  9. South Carolina Natural Gas Input Supplemental Fuels (Million Cubic Feet)

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5 Tables July 1996 Energy Information Administration Office ofthroughYear Jan FebDecadeDecade Year-0 Year-1 Year-2 Year-3DecadeInput

  10. South Dakota Natural Gas Input Supplemental Fuels (Million Cubic Feet)

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5 Tables July 1996 Energy Information Administration Office ofthroughYear Jan FebDecadeDecade Year-0TotalH BV CYearInput Supplemental

  11. Louisiana Natural Gas Input Supplemental Fuels (Million Cubic Feet)

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5 Tables July 1996 Energy Information Administration Office of Coal,Cubic Feet)FuelDecade Year-0Input Supplemental Fuels (Million

  12. Maryland Natural Gas Input Supplemental Fuels (Million Cubic Feet)

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5 Tables July 1996 Energy Information Administration Office of Coal,Cubic Feet)FuelDecadePublication10.9919,923CubicFeet)Input

  13. Low Voltage Reversible Electrowetting Exploiting Lubricated Polymer Honeycomb Substrates

    E-Print Network [OSTI]

    Edward Bormashenko; Roman Pogreb; Yelena Bormashenko; Roman Grynyov; Oleg Gendelman

    2014-06-16T23:59:59.000Z

    Low-voltage electrowetting-on-dielectric scheme realized with lubricated honeycomb polymer surfaces is reported. Polycarbonate honeycomb reliefs manufactured with the breath-figures self-assembly were impregnated with silicone and castor oils. The onset of the reversible electrowetting for silicone oil impregnated substrates occurred at 35 V, whereas for castor oil impregnated ones it took place at 80 V. The semi-quantitative analysis of electrowetting of impregnated surfaces is proposed.

  14. Magnetic shielding of Hall thrusters at high discharge voltages

    SciTech Connect (OSTI)

    Mikellides, Ioannis G., E-mail: Ioannis.G.Mikellides@jpl.nasa.gov; Hofer, Richard R.; Katz, Ira; Goebel, Dan M. [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California 91109 (United States)

    2014-08-07T23:59:59.000Z

    A series of numerical simulations and experiments have been performed to assess the effectiveness of magnetic shielding in a Hall thruster operating in the discharge voltage range of 300–700?V (I{sub sp}???2000–2700?s) at 6?kW, and 800?V (I{sub sp} ? 3000) at 9?kW. At 6?kW, the magnetic field topology with which highly effective magnetic shielding was previously demonstrated at 300?V has been retained for all other discharge voltages; only the magnitude of the field has been changed to achieve optimum thruster performance. It is found that magnetic shielding remains highly effective for all discharge voltages studied. This is because the channel is long enough to allow hot electrons near the channel exit to cool significantly upon reaching the anode. Thus, despite the rise of the maximum electron temperature in the channel with discharge voltage, the electrons along the grazing lines of force remain cold enough to eliminate or reduce significantly parallel gradients of the plasma potential near the walls. Computed maximum erosion rates in the range of 300–700?V are found not to exceed 10{sup ?2}?mm/kh. Such rates are ?3 orders of magnitude less than those observed in the unshielded version of the same thruster at 300?V. At 9?kW and 800?V, saturation of the magnetic circuit did not allow for precisely the same magnetic shielding topology as that employed during the 6-kW operation since this thruster was not designed to operate at this condition. Consequently, the maximum erosion rate at the inner wall is found to be ?1 order of magnitude higher (?10{sup ?1}?mm/kh) than that at 6?kW. At the outer wall, the ion energy is found to be below the sputtering yield threshold so no measurable erosion is expected.

  15. Linear inductive voltage adders (IVA) for advanced hydrodynamic radiography

    SciTech Connect (OSTI)

    Mazarakis, M.G.; Boyes, J.D.; Johnson, D.L. [and others

    1998-09-01T23:59:59.000Z

    The electron beam which drifts through the multiple cavities of conventional induction linacs (LIA) is replaced in an IVA by a cylindrical metal conductor which extends along the entire length of the device and effectuates the addition of the accelerator cavity voltages. In the approach to radiography, the linear inductive voltage adder drives a magnetically immersed electron diode with a millimeter diameter cathode electrode and a planar anode/bremsstrahlung converter. Both anode and cathode electrodes are immersed in a strong (15--50 T) solenoidal magnetic field. The electron beam cross section is approximately of the same size as the cathode needle and generates a similar size, very intense x-ray beam when it strikes the anode converter. An IVA driven diode can produce electron beams of equal size and energy as a LIA but with much higher currents (40--50 kA versus 4--5 kA), simpler hardware and thus lower cost. The authors present here first experimental validations of the technology utilizing HERMES 3 and SABRE IVA accelerators. The electron beam voltage and current were respectively of the order of 10 MV and 40 kA. X-ray doses of up to 1 kR {at} 1 m and spot sizes as small as 1.7 mm (at 200 R doses) were measured.

  16. Fiber optic current monitor for high-voltage applications

    DOE Patents [OSTI]

    Renda, G.F.

    1992-04-21T23:59:59.000Z

    A current monitor which derives its power from the conductor being measured for bidirectionally measuring the magnitude of current (from DC to above 50 khz) flowing through a conductor across which a relatively high level DC voltage is applied, includes a pair of identical transmitter modules connected in opposite polarity to one another in series with the conductor being monitored, for producing from one module a first light signal having an intensity directly proportional to the magnitude of current flowing in one direction through the conductor during one period of time, and from the other module a second light signal having an intensity directly proportional to the magnitude of current flowing in the opposite direction through the conductor during another period of time, and a receiver located in a safe area remote from the high voltage area for receiving the first and second light signals, and converting the same to first and second voltage signals having levels indicative of the magnitude of current being measured at a given time. 6 figs.

  17. Advanced Gate Drive for the SNS High Voltage Converter Modulator

    SciTech Connect (OSTI)

    Nguyen, M.N.; Burkhart, C.; Kemp, M.A.; /SLAC; Anderson, D.E.; /Oak Ridge

    2009-05-07T23:59:59.000Z

    SLAC National Accelerator Laboratory is developing a next generation H-bridge switch plate [1], a critical component of the SNS High Voltage Converter Modulator [2]. As part of that effort, a new IGBT gate driver has been developed. The drivers are an integral part of the switch plate, which are essential to ensuring fault-tolerant, high-performance operation of the modulator. The redesigned driver improves upon the existing gate drive in several ways. The new gate driver has improved fault detection and suppression capabilities; suppression of shoot-through and over-voltage conditions, monitoring of dI/dt and Vce(sat) for fast over-current detection and suppression, and redundant power isolation are some of the added features. In addition, triggering insertion delay is reduced by a factor of four compared to the existing driver. This paper details the design and performance of the new IGBT gate driver. A simplified schematic and description of the construction are included. The operation of the fast over-current detection circuits, active IGBT over-voltage protection circuit, shoot-through prevention circuitry, and control power isolation breakdown detection circuit are discussed.

  18. Thermally-induced voltage alteration for integrated circuit analysis

    DOE Patents [OSTI]

    Cole, Jr., Edward I. (Albuquerque, NM)

    2000-01-01T23:59:59.000Z

    A thermally-induced voltage alteration (TIVA) apparatus and method are disclosed for analyzing an integrated circuit (IC) either from a device side of the IC or through the IC substrate to locate any open-circuit or short-circuit defects therein. The TIVA apparatus uses constant-current biasing of the IC while scanning a focused laser beam over electrical conductors (i.e. a patterned metallization) in the IC to produce localized heating of the conductors. This localized heating produces a thermoelectric potential due to the Seebeck effect in any conductors with open-circuit defects and a resistance change in any conductors with short-circuit defects, both of which alter the power demand by the IC and thereby change the voltage of a source or power supply providing the constant-current biasing. By measuring the change in the supply voltage and the position of the focused and scanned laser beam over time, any open-circuit or short-circuit defects in the IC can be located and imaged. The TIVA apparatus can be formed in part from a scanning optical microscope, and has applications for qualification testing or failure analysis of ICs.

  19. Thermally-induced voltage alteration for analysis of microelectromechanical devices

    DOE Patents [OSTI]

    Walraven, Jeremy A. (Albuquerque, NM); Cole, Jr., Edward I. (Albuquerque, NM)

    2002-01-01T23:59:59.000Z

    A thermally-induced voltage alteration (TIVA) apparatus and method are disclosed for analyzing a microelectromechanical (MEM) device with or without on-board integrated circuitry. One embodiment of the TIVA apparatus uses constant-current biasing of the MEM device while scanning a focused laser beam over electrically-active members therein to produce localized heating which alters the power demand of the MEM device and thereby changes the voltage of the constant-current source. This changing voltage of the constant-current source can be measured and used in combination with the position of the focused and scanned laser beam to generate an image of any short-circuit defects in the MEM device (e.g. due to stiction or fabrication defects). In another embodiment of the TIVA apparatus, an image can be generated directly from a thermoelectric potential produced by localized laser heating at the location of any short-circuit defects in the MEM device, without any need for supplying power to the MEM device. The TIVA apparatus can be formed, in part, from a scanning optical microscope, and has applications for qualification testing or failure analysis of MEM devices.

  20. Voltage Stability and Power Quality Issues of Wind Farm with Series Compensation

    E-Print Network [OSTI]

    Pota, Himanshu Roy

    Voltage Stability and Power Quality Issues of Wind Farm with Series Compensation T. F. Orchi generator (DFIG) wind farms with series and shunt compensation are analyzed. The voltage source converter of the wind farm are modeled with flicker coefficients as defined by IEC standard 61400 and voltage sag

  1. Impact of Compiler Optimizations on Voltage Droops and Reliability of an SMT, Multi-Core Processor

    E-Print Network [OSTI]

    John, Lizy Kurian

    Impact of Compiler Optimizations on Voltage Droops and Reliability of an SMT, Multi-Core Processor unreliable operation in microprocessors. Voltage droops due to di/dt effects have been studied in the past, however no prior work studies the effect of compiler optimizations on voltage droops. Past work has

  2. Analysis of Instruction-level Vulnerability to Dynamic Voltage and Temperature Variations

    E-Print Network [OSTI]

    Gupta, Rajesh

    and supply voltage droops [2]. Static process variations can sometimes be mitigated through binning of dynamic variation from environmental and workload changes include supply voltage droops and temperature changes. Voltage droops result from abrupt changes in the switching activity, inducing large current

  3. October 6, 2006 V. Ghazikhanian 1 TOF Low Voltage System Review

    E-Print Network [OSTI]

    Llope, William J.

    TOF Low Voltage Power System. The TOF low voltage system is based on the Wiener PL512 low noise, high45 plugs #12;October 6, 2006 V. Ghazikhanian Tray Low Voltage Power System. Totalof120 the plot of the dark current data on slide]. The DC power will be transmitted via DC transmission lines

  4. An earth-isolated optically coupled wideband high voltage probe powered by ambient light

    E-Print Network [OSTI]

    Bellan, Paul M.

    An earth-isolated optically coupled wideband high voltage probe powered by ambient light Xiang Zhai) An earth-isolated optically coupled wideband high voltage probe powered by ambient light Xiang Zhaia online 9 October 2012) An earth-isolated optically-coupled wideband high voltage probe has been developed

  5. Parameter Variation Analysis for Voltage Controlled Oscillators in Phase-Locked Loops

    E-Print Network [OSTI]

    Moon, Un-Ku

    Parameter Variation Analysis for Voltage Controlled Oscillators in Phase-Locked Loops Igor Vytyaz), the oscillation frequency of a voltage-controlled oscillator (VCO) is specified by the reference frequency on the oscillation frequency as the PLL adjusts the control voltage to keep the frequency unchanged. More importantly

  6. 1. ABSTRACT A 1.4-GHz LC voltage-controlled oscillator has

    E-Print Network [OSTI]

    Lee, Thomas H.

    1. ABSTRACT A 1.4-GHz LC voltage-controlled oscillator has been implemented in a MOSIS 0.5-µm CMOS integrated, low noise, low power voltage-controlled oscillator (VCO). For higher quality receivers, an LC the overall phase noise. In this paper, we present such an LC voltage-controlled oscillator fabricated through

  7. EFFECTS OF SUBSTRATE ON PHASE-NOISE OF BIPOLAR VOLTAGE-CONTROLLED OSCILLATORS

    E-Print Network [OSTI]

    Serdijn, Wouter A.

    EFFECTS OF SUBSTRATE ON PHASE-NOISE OF BIPOLAR VOLTAGE-CONTROLLED OSCILLATORS Aleksandar Tasic predict a dramatically different performance of the oscillators, being different phase-noise, voltage of quasi-tapped bipolar voltage-controlled oscillators [2], phase- noise being of most interest. Contrary

  8. Fast Optimization of Nano-CMOS Voltage-Controlled Oscillator using Polynomial Regression and Genetic Algorithm

    E-Print Network [OSTI]

    Mohanty, Saraju P.

    Fast Optimization of Nano-CMOS Voltage-Controlled Oscillator using Polynomial Regression in a current-starved 50nm voltage-controlled oscillator (VCO). Accurate polynomial-regression based models have-CMOS), Voltage-Controlled Oscillator (VCO). 1. Introduction Digital design exploration and optimization is highly

  9. CONCEPT OF FREQUENCY-TRANSCONDUCTANCE TUNING OF BIPOLAR VOLTAGE-CONTROLLED OSCILLATORS

    E-Print Network [OSTI]

    Serdijn, Wouter A.

    CONCEPT OF FREQUENCY-TRANSCONDUCTANCE TUNING OF BIPOLAR VOLTAGE-CONTROLLED OSCILLATORS Aleksandar-transconductance tuning, introduced in this paper, offers the possibility for voltage-controlled oscillators to trade-tank, the loop-gain, the voltage swing and the phase-noise of the oscillator are changed as well

  10. Understanding Pound-Drever-Hall locking using voltage controlled radio-frequency oscillators: An undergraduate experiment

    E-Print Network [OSTI]

    Le Roy, Robert J.

    Understanding Pound-Drever-Hall locking using voltage controlled radio-frequency oscillators. The three main pieces of equipment are a commercial voltage controlled oscillator, a resonating cavity of the voltage controlled oscillator. The cavity resonance is then observed by scanning the frequency

  11. The vertical voltage termination technique characterizations of single die multiple 600V power

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    The vertical voltage termination technique ­ characterizations of single die multiple 600V power.grenoble-inp.fr Abstract-- Deep trench terminations are commonly known as a technique to achieve ideal breakdown voltages for high voltage devices. This paper presents the use of deep trench terminations as an original concept

  12. Measurement based Voltage Stability Monitoring of Power system Garng M. Huang

    E-Print Network [OSTI]

    Measurement based Voltage Stability Monitoring of Power system Garng M. Huang huang Station, TX 77843-3128 Abstract: Many papers discuss the voltage stability assessment of power system. The problem of voltage stability may be simply explained as inability of the power system to provide

  13. Low-Voltage Ride-Through Techniques for DFIG-Based Wind Turbines

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Low-Voltage Ride-Through Techniques for DFIG-Based Wind Turbines: State-of-the-Art Review deals with low-voltage ride-through (LVRT) capability of wind turbines (WTs) and in particular those as to index some emerging solutions. Index Terms--Wind turbine, doubly-fed induction generator, low voltage

  14. Voltage-Sensitivity of Motoneuron NMDA Receptor Channels Is Modulated by Serotonin in the Neonatal Rat Spinal Cord

    E-Print Network [OSTI]

    Manitoba, University of

    isolated in tetrodotoxin, induces nonlinear membrane behavior that results in voltage oscillations which generate rhythmic voltage oscillations in the presence of NMDA and synaptic blockade (with tetrodotoxin application induces neither voltage oscillations (in synaptically isolated motoneurons) nor locomotor network

  15. Input-output multiplier distributions from probabilistic production paths

    SciTech Connect (OSTI)

    Konecny, R.T.

    1987-01-01T23:59:59.000Z

    In the standard Leontief input-output model, a single dominant technology is assumed in the production of a particular commodity. However, in the real world, quite similar commodities are produced by firms with vastly different technologies. In addressing this limitation, the Probabilistic Production Path model (PPP) is used to investigate both the method of production and identity of the producer. An important feature of the PPP model is the consideration of the effects that heterogeneous technologies and dissimilar trade patterns have on the properties of the distribution of input-output multipliers. The derivation of the distribution of output multipliers is generalized for discrete probabilities based on market shares. Due to the complexity of the generalized solution, a simulation model is used to approximate the multiplier distribution. Results of the model show that the distributional properties of the multipliers are unpredictable, with the majority of the distributions being multimodal. Typically, the mean of the multipliers lies in a trough between two modes. Multimodal multiplier distributions were found to have a tighter symmetric interval than the corresponding standard normal confidence interval. Therefore, the use of the normal confidence interval appears to be sufficient, though overstated, for the construction of confidence intervals in the PPP model.

  16. RF Input Power Couplers for High Current SRF Applications

    SciTech Connect (OSTI)

    Khan, V. F. [Helmholtz Zentrum Berlin, Germany; Anders, W. [Helmholtz Zentrum Berlin, Germany; Burrill, Andrew [Helmholtz Zentrum Berlin, Germany; Knobloch, Jens [Helmholtz Zentrum Berlin, Germany; Kugeler, Oliver [Helmholtz Zentrum Berlin, Germany; Neumann, Axel [Helmholtz Zentrum Berlin, Germany; Wang, Haipeng [JLAB

    2014-12-01T23:59:59.000Z

    High current SRF technology is being explored in present day accelerator science. The bERLinPro project is presently being built at HZB to address the challenges involved in high current SRF machines with the goal of generating and accelerating a 100 mA electron beam to 50 MeV in continuous wave (cw) mode at 1.3 GHz. One of the main challenges in this project is that of handling the high input RF power required for the photo-injector as well as booster cavities where there is no energy recovery process. A high power co-axial input power coupler is being developed to be used for the photo-injector and booster cavities at the nominal beam current. The coupler is based on the KEK–cERL design and has been modified to minimise the penetration of the coupler tip in the beam pipe without compromising on beam-power coupling (Qext ~105). Herein we report on the RF design of the high power (115 kW per coupler, dual couplers per cavity) bERLinPro (BP) coupler along with initial results on thermal calculations. We summarise the RF conditioning of the TTF-III couplers (modified for cw operation) performed in the past at BESSY/HZB. A similar conditioning is envisaged in the near future for the low current SRF photo-injector and the bERLinPro main linac cryomodule.

  17. Strategies for Voltage Control and Transient Stability Assessment

    SciTech Connect (OSTI)

    Hiskens, Ian A.

    2013-09-25T23:59:59.000Z

    As wind generation grows, its influence on power system performance will becoming increasingly noticeable. Wind generation di#11;ffers from traditional forms of generation in numerous ways though, motivating the need to reconsider the usual approaches to power system assessment and performance enhancement. The project has investigated the impact of wind generation on transient stability and voltage control, identifying and addressing issues at three distinct levels of the power system: 1) at the device level, the physical characteristics of wind turbine generators (WTGs) are quite unlike those of synchronous machines, 2) at the wind-farm level, the provision of reactive support is achieved through coordination of numerous dissimilar devices, rather than straightforward generator control, and 3) from a systems perspective, the location of wind-farms on the sub-transmission network, coupled with the variability inherent in their power output, can cause complex voltage control issues. The project has sought to develop a thorough understanding of the dynamic behaviour of type-3 WTGs, and in particular the WECC generic model. The behaviour of such models is governed by interactions between the continuous dynamics of state variables and discrete events associated with limits. It was shown that these interactions can be quite complex, and may lead to switching deadlock that prevents continuation of the trajectory. Switching hysteresis was proposed for eliminating deadlock situations. Various type-3 WTG models include control blocks that duplicate integrators. It was shown that this leads to non-uniqueness in the conditions governing steady-state, and may result in pre- and post-disturbance equilibria not coinciding. It also gives rise to a zero eigenvalue in the linearized WTG model. In order to eliminate the anomalous behaviour revealed through this investigation, WECC has now released a new generic model for type-3 WTGs. Wind-farms typically incorporate a variety of voltage control equipment including tapchanging transformers, switched capacitors, SVCs, STATCOMs and the WTGs themselves. The project has considered the coordinated control of this equipment, and has addressed a range of issues that arise in wind-farm operation. The #12;first concerns the ability of WTGs to meet reactive power requirements when voltage saturation in the collector network restricts the reactive power availability of individual generators. Secondly, dynamic interactions between voltage regulating devices have been investigated. It was found that under certain realistic conditions, tap-changing transformers may exhibit instability. In order to meet cost, maintenance, fault tolerance and other requirements, it is desirable for voltage control equipment to be treated as an integrated system rather than as independent devices. The resulting high-level scheduling of wind-farm reactive support has been investigated. In addressing this control problem, several forms of future information were considered, including exact future knowledge and stochastic predictions. Deterministic and Stochastic Dynamic Programming techniques were used in the development of control algorithms. The results demonstrated that while exact future knowledge is very useful, simple prediction methods yield little bene#12;fit. The integration of inherently variable wind generation into weak grids, particularly subtransmission networks that are characterized by low X=R ratios, aff#11;ects bus voltages, regulating devices and line flows. The meshed structure of these networks adds to the complexity, especially when wind generation is distributed across multiple nodes. A range of techniques have been considered for analyzing the impact of wind variability on weak grids. Sensitivity analysis, based on the power-flow Jacobian, was used to highlight sections of a system that are most severely a#11;ffected by wind-power variations. A continuation power flow was used to determine parameter changes that reduce the impact of wind-power variability. It was also used to explore interactions betw

  18. Soil-related Input Parameters for the Biosphere Model

    SciTech Connect (OSTI)

    A. J. Smith

    2003-07-02T23:59:59.000Z

    This analysis is one of the technical reports containing documentation of the Environmental Radiation Model for Yucca Mountain Nevada (ERMYN), a biosphere model supporting the Total System Performance Assessment (TSPA) for the geologic repository at Yucca Mountain. The biosphere model is one of a series of process models supporting the Total System Performance Assessment (TSPA) for the Yucca Mountain repository. A graphical representation of the documentation hierarchy for the ERMYN biosphere model is presented in Figure 1-1. This figure shows the interrelationships among the products (i.e., analysis and model reports) developed for biosphere modeling, and the plan for development of the biosphere abstraction products for TSPA, as identified in the ''Technical Work Plan: for Biosphere Modeling and Expert Support'' (BSC 2003 [163602]). It should be noted that some documents identified in Figure 1-1 may be under development at the time this report is issued and therefore not available. This figure is included to provide an understanding of how this analysis report contributes to biosphere modeling in support of the license application, and is not intended to imply that access to the listed documents is required to understand the contents of this report. This report, ''Soil Related Input Parameters for the Biosphere Model'', is one of the five analysis reports that develop input parameters for use in the ERMYN model. This report is the source documentation for the six biosphere parameters identified in Table 1-1. ''The Biosphere Model Report'' (BSC 2003 [160699]) describes in detail the conceptual model as well as the mathematical model and its input parameters. The purpose of this analysis was to develop the biosphere model parameters needed to evaluate doses from pathways associated with the accumulation and depletion of radionuclides in the soil. These parameters support the calculation of radionuclide concentrations in soil from on-going irrigation and ash deposition and, as a direct consequence, radionuclide concentration in resuspended particulate matter in the atmosphere. The analysis was performed in accordance with the technical work plan for the biosphere modeling and expert support (TWP) (BSC 2003 [163602]). This analysis revises the previous one titled ''Evaluate Soil/Radionuclide Removal by Erosion and Leaching'' (CRWMS M&O 2001 [152517]). In REV 00 of this report, the data generated were fixed (i.e., taking no account of uncertainty and variability) values. This revision incorporates uncertainty and variability into the values for the bulk density, elemental partition coefficients, average annual loss of soil from erosion, resuspension enhancement factor, and field capacity water content.

  19. Phase Noise in MIMO Systems: Bayesian Cramer-Rao Bounds and Soft-Input Estimation

    E-Print Network [OSTI]

    Nasir, Ali A; Mehrpouyan, Hani; Schober, Robert; Hua, Yingbo

    2013-01-01T23:59:59.000Z

    for a 4 4 MIMO system, the proposed soft-input EKF-EKSin MIMO Systems: Bayesian Cramér–Rao Bounds and Soft-Inputof a MIMO system employing the proposed soft-input EKF-EKS

  20. Spatial Interference Mitigation for Multiple Input Multiple Output Ad Hoc Networks: MISO Gains

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Spatial Interference Mitigation for Multiple Input Multiple Output Ad Hoc Networks: MISO Gains beamforming for a multiple input single output (MISO) ad hoc network to increase the density of successful

  1. V-124: Splunk Web Input Validation Flaw Permits Cross-Site Scripting...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    4: Splunk Web Input Validation Flaw Permits Cross-Site Scripting Attacks V-124: Splunk Web Input Validation Flaw Permits Cross-Site Scripting Attacks April 2, 2013 - 1:13am Addthis...

  2. Calibration of a Distributed Flood Forecasting Model with Input Uncertainty Using a Bayesian Framework

    E-Print Network [OSTI]

    Hubbard, Susan

    Calibration of a Distributed Flood Forecasting Model with Input Uncertainty Using a Bayesian, Berkeley, CA, United States. In the process of calibrating distributed hydrological models, accounting in calibrating GBHM parameters and in estimating their associated uncertainty. The calibration ignoring input

  3. Methods for Rapid Estimation of Motor Input Power in HVAC Assessments

    E-Print Network [OSTI]

    Christman, Kevin D.

    2011-08-08T23:59:59.000Z

    In preliminary building energy assessments, it is often desired to estimate a motor's input power. Motor power estimates in this context should be rapid, safe, and noninvasive. Existing methods for motor input power estimation, such as direct...

  4. BETO Seeks Stakeholder Input on the Use of Advanced Biofuel Blends...

    Energy Savers [EERE]

    BETO Seeks Stakeholder Input on the Use of Advanced Biofuel Blends in Small Engines BETO Seeks Stakeholder Input on the Use of Advanced Biofuel Blends in Small Engines June 22,...

  5. The design of efficient input circuits for class C amplifiers

    E-Print Network [OSTI]

    Fristoe, Harold T.

    1953-01-01T23:59:59.000Z

    the design of efficient input circuits for c u s s c amplifiers t heddsigngeof cpi utramh lX jr?cla? t??io?s? nd go dg??s nf? ?ofgsfg ??e usn? o? ??s?gie?n? ?f?efssief? hs?nig ?sfg theds igno lu? h?c??? fc ?jj?????l ????l ??r???lc jar ??cc...????????cXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX ?? ?X ?a??m?c?a?cXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX ?? t??sf?e? ? ? c???ni? o? g?s hsde?f ?io?s??is ? ? ? ? ? ? ? ? ? ? ?? m?cl aj j???r?c je??is ?n?s ?X l?s ?ofdgnfg ??iisfg ?ofdgi??geof ?oi hsgsi?efef? ??ndd ? a...

  6. Soil-Related Input Parameters for the Biosphere Model

    SciTech Connect (OSTI)

    A. J. Smith

    2004-09-09T23:59:59.000Z

    This report presents one of the analyses that support the Environmental Radiation Model for Yucca Mountain Nevada (ERMYN). The ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) describes the details of the conceptual model as well as the mathematical model and the required input parameters. The biosphere model is one of a series of process models supporting the postclosure Total System Performance Assessment (TSPA) for the Yucca Mountain repository. A schematic representation of the documentation flow for the Biosphere input to TSPA is presented in Figure 1-1. This figure shows the evolutionary relationships among the products (i.e., analysis and model reports) developed for biosphere modeling, and the biosphere abstraction products for TSPA, as identified in the ''Technical Work Plan for Biosphere Modeling and Expert Support'' (TWP) (BSC 2004 [DIRS 169573]). This figure is included to provide an understanding of how this analysis report contributes to biosphere modeling in support of the license application, and is not intended to imply that access to the listed documents is required to understand the contents of this report. This report, ''Soil-Related Input Parameters for the Biosphere Model'', is one of the five analysis reports that develop input parameters for use in the ERMYN model. This report is the source documentation for the six biosphere parameters identified in Table 1-1. The purpose of this analysis was to develop the biosphere model parameters associated with the accumulation and depletion of radionuclides in the soil. These parameters support the calculation of radionuclide concentrations in soil from on-going irrigation or ash deposition and, as a direct consequence, radionuclide concentration in other environmental media that are affected by radionuclide concentrations in soil. The analysis was performed in accordance with the TWP (BSC 2004 [DIRS 169573]) where the governing procedure was defined as AP-SIII.9Q, ''Scientific Analyses''. This analysis revises the previous version with the same name (BSC 2003 [DIRS 161239]), which was itself a revision of one titled ''Evaluate Soil/Radionuclide Removal by Erosion and Leaching'' (CRWMS M&O 2001 [DIRS 152517]). In Revision 00 of this report, the data generated were fixed values (i.e., taking no account of uncertainty and variability). Revision 01 (BSC 2003 [DIRS 161239]) incorporated uncertainty and variability into the values for the bulk density, elemental partition coefficients, average annual loss of soil from erosion, resuspension enhancement factor, and field capacity water content. The current revision of this document improves the transparency and traceability of the products without changing the details of the analysis. This analysis report supports the treatment of six of the features, events, and processes (FEPs) applicable to the Yucca Mountain reference biosphere (DTN: MO0407SEPFEPLA.000 [DIRS 170760]). The use of the more recent FEP list in DTN: MO0407SEPFEPLA.000 [DIRS 170760] represents a deviation from the detail provided in the TWP (BSC 2004 [DIRS 169573]), which referenced a previous version of the FEP list. The parameters developed in this report support treatment of these six FEPs addressed in the biosphere model that are listed in Table 1-1. Inclusion and treatment of FEPs in the biosphere model is described in the ''Biosphere Model Report'' (BSC 2004 [DIRS 169460], Section 6.2).

  7. Methods, systems and apparatus for controlling third harmonic voltage when operating a multi-space machine in an overmodulation region

    SciTech Connect (OSTI)

    Perisic, Milun; Kinoshita, Michael H; Ranson, Ray M; Gallegos-Lopez, Gabriel

    2014-06-03T23:59:59.000Z

    Methods, system and apparatus are provided for controlling third harmonic voltages when operating a multi-phase machine in an overmodulation region. The multi-phase machine can be, for example, a five-phase machine in a vector controlled motor drive system that includes a five-phase PWM controlled inverter module that drives the five-phase machine. Techniques for overmodulating a reference voltage vector are provided. For example, when the reference voltage vector is determined to be within the overmodulation region, an angle of the reference voltage vector can be modified to generate a reference voltage overmodulation control angle, and a magnitude of the reference voltage vector can be modified, based on the reference voltage overmodulation control angle, to generate a modified magnitude of the reference voltage vector. By modifying the reference voltage vector, voltage command signals that control a five-phase inverter module can be optimized to increase output voltages generated by the five-phase inverter module.

  8. Soft-Input Soft-Output King Decoder for Coded MIMO Wireless Communications

    E-Print Network [OSTI]

    Soft-Input Soft-Output King Decoder for Coded MIMO Wireless Communications Giuseppe PAPA, Domenico,{domenico.ciuonzo,gianmarco.romano,pierluigi.salvorossi}@unina2.it Abstract--This paper presents a Soft-Input Soft-Output (SISO) version of the King Decoder (KD for Multiple-Input Multiple-Output (MIMO) communication systems. More specifically, four versions of the KD

  9. On the Wind Power Input to the Ocean General Circulation XIAOMING ZHAI

    E-Print Network [OSTI]

    Johnson, Helen

    On the Wind Power Input to the Ocean General Circulation XIAOMING ZHAI Atmospheric, Oceanic January 2012, in final form 3 May 2012) ABSTRACT The wind power input to the ocean general circulation is usually calculated from the time-averaged wind products. Here, this wind power input is reexamined using

  10. Making Gestural Input from Arm-Worn Inertial Sensors More Practical

    E-Print Network [OSTI]

    Rajamani, Sriram K.

    .g., in a wristwatch) can sense arm gestures, enabling natural input in untethered scenarios. Two core components input with a wide variety of applications is arm movement detected by inertial sensors embedded transformation of the input space. For example, two users of different heights per- forming the same gesture

  11. Abstract--In this paper, we present the voltage build up process and the terminal voltage control of an isolated wind

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Abstract-- In this paper, we present the voltage build up process and the terminal voltage control that when capacitors are connected across the stator terminals of an induction machine, driven in the stator will continue to grow until steady-state condition is reached [2, 3]. However, self excitation has

  12. Induction of nuclear fission by high-voltage application

    E-Print Network [OSTI]

    Hirokazu Maruyama

    2007-11-20T23:59:59.000Z

    In nuclear power generation, fissile materials are mainly used. For example, $U^{235}$ is fissile and therefore quite essential for use of nuclear energy. However, the material $U^{235}$ has very small natural abundance less than 1 %. We should seek possibility of utilizing fissionable materials such as $U^{238}$ because natural abundance of such fissionable materials is generally much larger than fissile ones. In this paper, we show that thermal neutrons with vanishing kinetic energy can induce nuclear fission when high voltage is applied to fissionable materials. To obtain this result, we use the liquid-drop model for nuclei. Finally, we propose how fissionable materials can be utilized.

  13. Worldwide reliability surveys of high voltage circuit breakers

    SciTech Connect (OSTI)

    Heising, C.R.

    1995-05-01T23:59:59.000Z

    This article reports on the results of two CIGRE 13.06 Working Group worldwide surveys of the reliability of high voltage circuit breakers, 63 kV and above. The first inquiry included 78,000 breaker-years of ``in service data`` from 102 utilities in 22 countries during the years 1974--1977 and included all interrupting technologies. The second inquiry included 70,708 breaker-years from 132 utilities in 22 countries for the years 1988--1991 and only included single-pressure SF6 breakers, because this is what most utilities are now buying. Thirty-one US utilities submitted data.

  14. Light-weight DC to very high voltage DC converter

    DOE Patents [OSTI]

    Druce, Robert L. (Union City, CA); Kirbie, Hugh C. (Dublin, CA); Newton, Mark A. (Livermore, CA)

    1998-01-01T23:59:59.000Z

    A DC-DC converter capable of generating outputs of 100 KV without a transformer comprises a silicon opening switch (SOS) diode connected to allow a charging current from a capacitor to flow into an inductor. When a specified amount of charge has flowed through the SOS diode, it opens up abruptly; and the consequential collapsing field of the inductor causes a voltage and current reversal that is steered into a load capacitor by an output diode. A switch across the series combination of the capacitor, inductor, and SOS diode closes to periodically reset the SOS diode by inducing a forward-biased current.

  15. Light-weight DC to very high voltage DC converter

    DOE Patents [OSTI]

    Druce, R.L.; Kirbie, H.C.; Newton, M.A.

    1998-06-30T23:59:59.000Z

    A DC-DC converter capable of generating outputs of 100 KV without a transformer comprises a silicon opening switch (SOS) diode connected to allow a charging current from a capacitor to flow into an inductor. When a specified amount of charge has flowed through the SOS diode, it opens up abruptly; and the consequential collapsing field of the inductor causes a voltage and current reversal that is steered into a load capacitor by an output diode. A switch across the series combination of the capacitor, inductor, and SOS diode closes to periodically reset the SOS diode by inducing a forward-biased current. 1 fig.

  16. Outdoor PV Module Degradation of Current-Voltage Parameters: Preprint

    SciTech Connect (OSTI)

    Smith, R. M.; Jordan, D. C.; Kurtz, S. R.

    2012-04-01T23:59:59.000Z

    Photovoltaic (PV) module degradation rate analysis quantifies the loss of PV power output over time and is useful for estimating the impact of degradation on the cost of energy. An understanding of the degradation of all current-voltage (I-V) parameters helps to determine the cause of the degradation and also gives useful information for the design of the system. This study reports on data collected from 12 distinct mono- and poly-crystalline modules deployed at the National Renewable Energy Laboratory (NREL) in Golden, Colorado. Most modules investigated showed < 0.5%/year decrease in maximum power due to short-circuit current decline.

  17. Self-monitoring high voltage transmission line suspension insulator

    DOE Patents [OSTI]

    Stemler, Gary E. (Vancouver, WA); Scott, Donald N. (Vancouver, WA)

    1981-01-01T23:59:59.000Z

    A high voltage transmission line suspension insulator (18 or 22) which monitors its own dielectric integrity. A dielectric rod (10) has one larger diameter end fitting attachable to a transmission line and another larger diameter end fitting attachable to a support tower. The rod is enclosed in a dielectric tube (14) which is hermetically sealed to the rod's end fittings such that a liquidtight space (20) is formed between the rod and the tube. A pressurized dielectric liquid is placed within that space. A discoloring dye placed within this space is used to detect the loss of the pressurized liquid.

  18. Light-induced voltage alteration for integrated circuit analysis

    DOE Patents [OSTI]

    Cole, E.I. Jr.; Soden, J.M.

    1995-07-04T23:59:59.000Z

    An apparatus and method are described for analyzing an integrated circuit (IC). The invention uses a focused light beam that is scanned over a surface of the IC to generate a light-induced voltage alteration (LIVA) signal for analysis of the IC. The LIVA signal may be used to generate an image of the IC showing the location of any defects in the IC; and it may be further used to image and control the logic states of the IC. The invention has uses for IC failure analysis, for the development of ICs, for production-line inspection of ICs, and for qualification of ICs. 18 figs.

  19. Low Voltage Cables Market Analysis | OpenEI Community

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand Jump to: navigation, searchOf KilaueaInformation Other4Q07) WindLow Voltage Cables Market Analysis

  20. Low Voltage Cables Market Trends | OpenEI Community

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand Jump to: navigation, searchOf KilaueaInformation Other4Q07) WindLow Voltage Cables Market

  1. Low Voltage Cables Market size | OpenEI Community

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand Jump to: navigation, searchOf KilaueaInformation Other4Q07) WindLow Voltage Cables MarketLow

  2. Low Voltage Cables Market | OpenEI Community

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand Jump to: navigation, searchOf KilaueaInformation Other4Q07) WindLow Voltage Cables MarketLowLow

  3. HIGH-VOLTAGE SPINEL AND POLYANION CATHODES | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't YourTransport(Fact Sheet), GeothermalGrid Integration0-1HAWAI'I CLEANDepartmentDOEHIGH-VOLTAGE

  4. An accurate continuous calibration system for high voltage current transformer

    SciTech Connect (OSTI)

    Tong Yue; Li Binhong [College of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, Hubei Province (China)

    2011-02-15T23:59:59.000Z

    A continuous calibration system for high voltage current transformers is presented in this paper. The sensor of this system is based on a kind of electronic instrument current transformer, which is a clamp-shape air core coil. This system uses an optical fiber transmission system for its signal transmission and power supply. Finally the digital integrator and fourth-order convolution window algorithm as error calculation methods are realized by the virtual instrument with a personal computer. It is found that this system can calibrate a high voltage current transformer while energized, which means avoiding a long calibrating period in the power system and the loss of power metering expense. At the same time, it has a wide dynamic range and frequency band, and it can achieve a high accuracy measurement in a complex electromagnetic field environment. The experimental results and the on-site operation results presented in the last part of the paper, prove that it can reach the 0.05 accuracy class and is easy to operate on site.

  5. Commercialization of Medium Voltage HTS Triax TM Cable Systems

    SciTech Connect (OSTI)

    Knoll, David

    2012-12-31T23:59:59.000Z

    The original project scope that was established in 2007 aimed to install a 1,700 meter (1.1 mile) medium voltage HTS Triax{TM} cable system into the utility grid in New Orleans, LA. In 2010, however, the utility partner withdrew from the project, so the 1,700 meter cable installation was cancelled and the scope of work was reduced. The work then concentrated on the specific barriers to commercialization of HTS cable technology. The modified scope included long-length HTS cable design and testing, high voltage factory test development, optimized cooling system development, and HTS cable life-cycle analysis. In 2012, Southwire again analyzed the market for HTS cables and deemed the near term market acceptance to be low. The scope of work was further reduced to the completion of tasks already started and to testing of the existing HTS cable system in Columbus, OH. The work completed under the project included: • Long-length cable modeling and analysis • HTS wire evaluation and testing • Cable testing for AC losses • Optimized cooling system design • Life cycle testing of the HTS cable in Columbus, OH • Project management. The 200 meter long HTS Triax{TM} cable in Columbus, OH was incorporated into the project under the initial scope changes as a test bed for life cycle testing as well as the site for an optimized HTS cable cooling system. The Columbus cable utilizes the HTS TriaxTM design, so it provided an economical tool for these of the project tasks.

  6. Experiment and Simulation of Dynamic Voltage Regulation in Multiple Distributed Energy Resources Systems

    SciTech Connect (OSTI)

    Xu, Yan [ORNL; Li, Fangxing [ORNL; Kueck, John D [ORNL; Rizy, D Tom [ORNL

    2007-01-01T23:59:59.000Z

    Distributed energy (DE) resources are power sources located near load centers and equipped with power electronics converters to interface with the grid, therefore it is feasible for DE to provide reactive power (along with active power) locally for dynamic voltage regulation. In this paper, a synchronous condenser and a microturbine with an inverter interface are implemented in parallel in a distribution system to regulate the local voltage. Developed voltage control schemes for the inverter and the synchronous condenser are presented. Experimental results show that both the inverter and the synchronous condenser can regulate the local voltage instantaneously although the dynamic response of the inverter is much faster than the synchronous condenser. In a system with multiple DEs performing local voltage regulation, the interaction between the DEs is studied. The simulation results show the relationship between the voltages in the system and the reactive power required for the voltage regulation. Also, integrated voltage regulation (multiple DEs performing voltage regulation) can increase the voltage regulation capability of DEs and reduce the capital and operating costs.

  7. Over Voltage in a Multi-sectioned Solenoid during a Quenching

    SciTech Connect (OSTI)

    Guo, Xinglong; Wang, Li; Pan, Heng; Wu, Hong; Liu, Xiaokun; Chen, Anbin; Green, M.A.; Xu, F.Y.

    2009-06-21T23:59:59.000Z

    Accurate analysis of over voltage in the superconducting solenoid during a quench is one of the bases for quench protection system design. Classical quench simulation methods can only give rough estimation of the over voltage within a magnet coil. In this paper, for multi-sectioned superconducting solenoid, based on the classical assumption of ellipsoidal normal zone, three-dimension al temperature results are mapped to the one-dimension of the wire, the temperature distribution along the wire and the resistances of each turn are obtained. The coil is treated as circuit comprised of turn resistances, turn self and mutual inductances. The turn resistive voltage, turn inductive voltage, and turn resultant voltage along the wire are calculated. As a result, maximum internal voltages, the layer-to-layer voltages and the turn-to-turn voltages are better estimated. Utilizing this method, the over voltage of a small solenoid and a large solenoid during quenching have been studied. The result shows that this method can well improve the over voltage estimate, especially when the coil is larger.

  8. Environmental Transport Input Parameters for the Biosphere Model

    SciTech Connect (OSTI)

    M. A. Wasiolek

    2003-06-27T23:59:59.000Z

    This analysis report is one of the technical reports documenting the Environmental Radiation Model for Yucca Mountain Nevada (ERMYN), a biosphere model supporting the total system performance assessment (TSPA) for the geologic repository at Yucca Mountain. A graphical representation of the documentation hierarchy for the ERMYN is presented in Figure 1-1. This figure shows relationships among the reports developed for biosphere modeling and biosphere abstraction products for the TSPA, as identified in the ''Technical Work Plan: for Biosphere Modeling and Expert Support'' (TWP) (BSC 2003 [163602]). Some documents in Figure 1-1 may be under development and not available when this report is issued. This figure provides an understanding of how this report contributes to biosphere modeling in support of the license application (LA), but access to the listed documents is not required to understand the contents of this report. This report is one of the reports that develops input parameter values for the biosphere model. The ''Biosphere Model Report'' (BSC 2003 [160699]) describes the conceptual model, the mathematical model, and the input parameters. The purpose of this analysis is to develop biosphere model parameter values related to radionuclide transport and accumulation in the environment. These parameters support calculations of radionuclide concentrations in the environmental media (e.g., soil, crops, animal products, and air) resulting from a given radionuclide concentration at the source of contamination (i.e., either in groundwater or volcanic ash). The analysis was performed in accordance with the TWP (BSC 2003 [163602]). This analysis develops values of parameters associated with many features, events, and processes (FEPs) applicable to the reference biosphere (DTN: M00303SEPFEPS2.000 [162452]), which are addressed in the biosphere model (BSC 2003 [160699]). The treatment of these FEPs is described in BSC (2003 [160699], Section 6.2). Parameter values developed in this report, and the related FEPs, are listed in Table 1-1. The relationship between the parameters and FEPs was based on a comparison of the parameter definition and the FEP descriptions as presented in BSC (2003 [160699], Section 6.2). The parameter values developed in this report support the biosphere model and are reflected in the TSPA through the biosphere dose conversion factors (BDCFs). Biosphere modeling focuses on radionuclides screened for the TSPA-LA (BSC 2002 [160059]). The same list of radionuclides is used in this analysis (Section 6.1.4). The analysis considers two human exposure scenarios (groundwater and volcanic ash) and climate change (Section 6.1.5). This analysis combines and revises two previous reports, ''Transfer Coefficient Analysis'' (CRWMS M&O 2000 [152435]) and ''Environmental Transport Parameter Analysis'' (CRWMS M&O 2001 [152434]), because the new ERMYN biosphere model requires a redefined set of input parameters. The scope of this analysis includes providing a technical basis for the selection of radionuclide- and element-specific biosphere parameters (except for Kd) that are important for calculating BDCFs based on the available radionuclide inventory abstraction data. The environmental transport parameter values were developed specifically for use in the biosphere model and may not be appropriate for other applications.

  9. DECENTRALIZED CONTROL ARCHITECTURE FOR COUPLING MICROGRIDS INTO DISTRIBUTION NETWORKS 1 Task 1: Coupling Low-Voltage Microgrids into

    E-Print Network [OSTI]

    Lemmon, Michael

    DECENTRALIZED CONTROL ARCHITECTURE FOR COUPLING MICROGRIDS INTO DISTRIBUTION NETWORKS 1 Task 1: Coupling Low-Voltage Microgrids into Mid-Voltage Distribution Systems Zhao Wang, Student Member, IEEE-voltage (LV) microgrids. At the same time, reactive power is dispatched coordinatively so that voltage

  10. Interface module for transverse energy input to dye laser modules

    DOE Patents [OSTI]

    English, R.E. Jr.; Johnson, S.A.

    1994-10-11T23:59:59.000Z

    An interface module for transverse energy input to dye laser modules is provided particularly for the purpose of delivering enhancing transverse energy beams in the form of illumination bar to the lasing zone of a dye laser device, in particular to a dye laser amplifier. The preferred interface module includes an optical fiber array having a plurality of optical fibers arrayed in a co-planar fashion with their distal ends receiving coherent laser energy from an enhancing laser source, and their proximal ends delivered into a relay structure. The proximal ends of the optical fibers are arrayed so as to be coplanar and to be aimed generally at a common point. The transverse energy beam array delivered from the optical fiber array is acted upon by an optical element array to produce an illumination bar which has a cross section in the form of a elongated rectangle at the position of the lasing window. The illumination bar is selected to have substantially uniform intensity throughout. 5 figs.

  11. Pulsed voltage electrospray ion source and method for preventing analyte electrolysis

    DOE Patents [OSTI]

    Kertesz, Vilmos (Knoxville, TN); Van Berkel, Gary (Clinton, TN)

    2011-12-27T23:59:59.000Z

    An electrospray ion source and method of operation includes the application of pulsed voltage to prevent electrolysis of analytes with a low electrochemical potential. The electrospray ion source can include an emitter, a counter electrode, and a power supply. The emitter can include a liquid conduit, a primary working electrode having a liquid contacting surface, and a spray tip, where the liquid conduit and the working electrode are in liquid communication. The counter electrode can be proximate to, but separated from, the spray tip. The power system can supply voltage to the working electrode in the form of a pulse wave, where the pulse wave oscillates between at least an energized voltage and a relaxation voltage. The relaxation duration of the relaxation voltage can range from 1 millisecond to 35 milliseconds. The pulse duration of the energized voltage can be less than 1 millisecond and the frequency of the pulse wave can range from 30 to 800 Hz.

  12. Bright and fast voltage reporters across the visible spectrum via electrochromic FRET (eFRET)

    E-Print Network [OSTI]

    Zou, Peng; Douglass, Adam D; Hochbaum, Daniel R; Brinks, Daan; Werley, Christopher A; Harrison, D Jed; Campbell, Robert E; Cohen, Adam E

    2014-01-01T23:59:59.000Z

    We present a palette of brightly fluorescent genetically encoded voltage indicators (GEVIs) with excitation and emission peaks spanning the visible spectrum, sensitivities from 6 - 10% Delta F/F per 100 mV, and half-maximal response times from 1 - 7 ms. A fluorescent protein is fused to an Archaerhodopsin-derived voltage sensor. Voltage-induced shifts in the absorption spectrum of the rhodopsin lead to voltage-dependent nonradiative quenching of the appended fluorescent protein. Through a library screen, we identified linkers and fluorescent protein combinations which reported neuronal action potentials in cultured rat hippocampal neurons with a single-trial signal-to-noise ratio from 6.6 to 11.6 in a 1 kHz imaging bandwidth at modest illumination intensity. The freedom to choose a voltage indicator from an array of colors facilitates multicolor voltage imaging, as well as combination with other optical reporters and optogenetic actuators.

  13. Understanding and Improving High Voltage Vacuum Insulators for Microsecond Pulses

    SciTech Connect (OSTI)

    Javedani, J B; Goerz, D A; Houck, T L; Lauer, E J; Speer, R D; Tully, L K; Vogtlin, G E; White, A D

    2007-03-05T23:59:59.000Z

    High voltage insulation is one of the main areas of pulsed power research and development, and dielectric breakdown is usually the limiting factor in attaining the highest possible performance in pulsed power devices. For many applications the delivery of pulsed power into a vacuum region is the most critical aspect of operation. The surface of an insulator exposed to vacuum can fail electrically at an applied field more than an order or magnitude below the bulk dielectric strength of the insulator. This mode of breakdown, called surface flashover, imposes serious limitations on the power flow into a vacuum region. This is especially troublesome for applications where high voltage conditioning of the insulator and electrodes is not practical and for applications where relatively long pulses, on the order of several microseconds, are required. The goal of this project is to establish a sound fundamental understanding of the mechanisms that lead to surface flashover, and then evaluate the most promising techniques to improve vacuum insulators and enable high voltage operation at stress levels near the intrinsic bulk breakdown limits of the material. The approach we proposed and followed was to develop this understanding through a combination of theoretical and computation methods coupled with experiments to validate and quantify expected behaviors. In this report we summarize our modeling and simulation efforts, theoretical studies, and experimental investigations. The computational work began by exploring the limits of commercially available codes and demonstrating methods to examine field enhancements and defect mechanisms at microscopic levels. Plasma simulations with particle codes used in conjunction with circuit models of the experimental apparatus enabled comparisons with experimental measurements. The large scale plasma (LSP) particle-in-cell (PIC) code was run on multiprocessor platforms and used to simulate expanding plasma conditions in vacuum gap regions. Algorithms were incorporated into LSP to handle secondary electron emission from dielectric materials to enable detailed simulations of flashover phenomenon. Theoretical studies were focused on explaining a possible mechanism for anode initiated surface flashover that involves an electron avalanche process starting near the anode, not a mechanism involving bulk dielectric breakdown. Experiments were performed in Engineering's Pulsed Power Lab using an available 100-kV, 10-{micro}s pulse generator and vacuum chamber. The initial experiments were done with polyethylene insulator material in the shape of a truncated cone cut at +45{sup o} angle between flat electrodes with a gap of 1.0 cm. The insulator was sized so there were no flashovers or breakdowns under nominal operating conditions. Insulator flashover or gap closure was induced by introducing a plasma source, a tuft of velvet, in proximity to the insulator or electrode.

  14. High-speed, sub-pull-in voltage MEMS switching.

    SciTech Connect (OSTI)

    Spahn, Olga Blum; Brewer, Steven; Olsson, Roy H.; Bogart, Gregory R.; Luck, David L.; Watts, Michael R.; Shaw, Michael J.; Nielson, Gregory N.; Resnick, Paul James; Tigges, Christopher P.; Grossetete, Grant David

    2008-01-01T23:59:59.000Z

    We have proposed and demonstrated MEMS switching devices that take advantage of the dynamic behavior of the MEMS devices to provide lower voltage actuation and higher switching speeds. We have explored the theory behind these switching techniques and have demonstrated these techniques in a range of devices including MEMS micromirror devices and in-plane parallel plate MEMS switches. In both devices we have demonstrated switching speeds under one microsecond which has essentially been a firm limit in MEMS switching. We also developed low-loss silicon waveguide technology and the ability to incorporate high-permittivity dielectric materials with MEMS. The successful development of these technologies have generated a number of new projects and have increased both the MEMS switching and optics capabilities of Sandia National Laboratories.

  15. (Insulating materials and large high voltage electric systems)

    SciTech Connect (OSTI)

    Dale, S.J.

    1990-09-18T23:59:59.000Z

    The traveler attended the 33rd Session of CIGRE (The International Conference on Large High Voltage Electric Systems in Paris, France) as a US technical expert advisor the Study Committee 15, Insulating Materials. Over 200 papers were discussed, contributed from over 45 countries at the conference on all aspects of electric power generation and transmission. Of special interest was a panel session on superconducting technology for electric power systems and the participation on a new task force on the electrical insulation at cryogenic temperatures. Significant insight was gained into the development of superconducting power technologies in Europe and Japan. CIGRE has set up a committee to follow the development in research on the biological effects of electric and magnetic fields. The traveler also visited the Centre for Electric Power Engineering at the University of Strathclyde, Glasgow, Scotland and discussed research on degradation of polymeric cable insulation and gas insulated equipment. 5 refs.

  16. DIII-D ICRF high voltage power supply regulator upgrade

    SciTech Connect (OSTI)

    Cary, W.P.; Burley, B.L.; Grosnickle, W.H.

    1997-11-01T23:59:59.000Z

    For reliable operation and component protection, of the 2 MW 30--120 MHz ICRF Amplifier System on DIII-D, it is desirable for the amplifier to respond to high VSWR conditions as rapidly as possible. This requires a rapid change in power which also means a rapid change in the high voltage power supply current demands. An analysis of the power supply`s regulator dynamics was needed to verify its expected operation during such conditions. Based on this information it was found that a new regulator with a larger dynamic range and some anticipation capability would be required. This paper will discuss the system requirements, the as-delivered regulator performance, and the improved performance after installation of the new regulator system. It will also be shown how this improvement has made the amplifier perform at higher power levels more reliably.

  17. Effect of high-voltage nanosecond pulses on complex plasmas

    SciTech Connect (OSTI)

    Pustylnik, M. Y.; Ivlev, A. V.; Thomas, H. M.; Morfill, G. E. [Max-Planck-Institut fuer Extraterrestrische Physik, Giessenbachstrasse, 85741 Garching (Germany); Vasilyak, L. M.; Vetchinin, S. P.; Polyakov, D. N.; Fortov, V. E. [Joint Institute for High Temperatures, Russian Academy of Sciences, Izhorskaya 13/19, 125412 Moscow (Russian Federation)

    2009-11-15T23:59:59.000Z

    Influence of high-voltage (1-11 kV) pulses of nanosecond (20 ns) duration on microparticles levitating in a rf plasma is studied. It is shown that the pulses produce significant influence on the plasma, causing perturbations with the relaxation time of the order of 10{sup -4} s. This time is sufficient for the microparticle to acquire significant kinetic energy. Application of repetitive pulses leads to the vertical oscillations of the microparticles. Clusters, consisting of small number of microparticles, exhibit parametric instabilities of horizontal modes under the effect of repetitive pulses. It was shown that the parametric instability is caused by the vertical oscillations of the microparticles in the nonuniform environment of the sheath.

  18. High-voltage atmospheric breakdown across intervening rutile dielectrics.

    SciTech Connect (OSTI)

    Williamson, Kenneth Martin; Simpson, Sean; Coats, Rebecca Sue; Jorgenson, Roy Eberhardt; Hjalmarson, Harold Paul; Pasik, Michael Francis

    2013-09-01T23:59:59.000Z

    This report documents work conducted in FY13 on electrical discharge experiments performed to develop predictive computational models of the fundamental processes of surface breakdown in the vicinity of high-permittivity material interfaces. Further, experiments were conducted to determine if free carrier electrons could be excited into the conduction band thus lowering the effective breakdown voltage when UV photons (4.66 eV) from a high energy pulsed laser were incident on the rutile sample. This report documents the numerical approach, the experimental setup, and summarizes the data and simulations. Lastly, it describes the path forward and challenges that must be overcome in order to improve future experiments for characterizing the breakdown behavior for rutile.

  19. Nanowire-based ternary transistor by threshold-voltage manipulation

    SciTech Connect (OSTI)

    Han, Junebeom; Lim, Taekyung; Bong, Jihye; Seo, Keumyoung; Ju, Sanghyun, E-mail: shju@kgu.ac.kr [Department of Physics, Kyonggi University, Suwon, Gyeonggi-Do 443-760 (Korea, Republic of); Kim, Sunkook [Department of Electronics and Radio Engineering, Kyung Hee University, Yongin, Gyeonggi-Do 446-701 (Korea, Republic of)

    2014-04-07T23:59:59.000Z

    We report on a ternary device consisting of two nanowire channels that have different threshold voltage (V{sub th}) values and show that three current stages can be produced. A microscale laser-beam shot was utilized to selectively anneal the nanowire channel area to be processed, and the amount of V{sub th} shift could be controlled by adjusting the laser wavelength. Microscale laser annealing process could control V{sub th} of the individual nanowire transistors while maintaining the other parameters the constant, such as the subthreshold slope, on–off current ratio, and mobility. This result could provide a potential for highly integrated and high-speed ternary circuits.

  20. Probabilistic Vulnerability Assessment Based on Power Flow and Voltage Distribution

    SciTech Connect (OSTI)

    Ma, Jian; Huang, Zhenyu; Wong, Pak C.; Ferryman, Thomas A.

    2010-04-30T23:59:59.000Z

    Risk assessment of large scale power systems has been an important problem in power system reliability study. Probabilistic technique provides a powerful tool to solve the task. In this paper, we present the results of a study on probabilistic vulnerability assessment on WECC system. Cumulant based expansion method is applied to obtain the probabilistic distribution function (PDF) and cumulative distribution function (CDF) of power flows on transmission lines and voltage. Overall risk index based on the system vulnerability analysis is calculated using the WECC system. The simulation results based on WECC system is used to demonstrate the effectiveness of the method. The methodology can be applied to the risk analysis on large scale power systems.

  1. High voltage design structure for high temperature superconducting device

    DOE Patents [OSTI]

    Tekletsadik, Kasegn D. (Rexford, NY)

    2008-05-20T23:59:59.000Z

    In accordance with the present invention, modular corona shields are employed in a HTS device to reduce the electric field surrounding the HTS device. In a exemplary embodiment a fault current limiter module in the insulation region of a cryogenic cooling system has at least one fault current limiter set which employs a first corona shield disposed along the top portion of the fault current limiter set and is electrically coupled to the fault current limiter set. A second corona shield is disposed along the bottom portion of the fault current limiter set and is electrically coupled to the fault current limiter set. An insulation barrier is disposed within the insulation region along at least one side of the fault current limiter set. The first corona shield and the second corona shield act together to reduce the electric field surrounding the fault limiter set when voltage is applied to the fault limiter set.

  2. System and method for floating-substrate passive voltage contrast

    DOE Patents [OSTI]

    Jenkins, Mark W. (Albuquerque, NM); Cole, Jr., Edward I. (Albuquerque, NM); Tangyunyong, Paiboon (Albuquerque, NM); Soden, Jerry M. (Placitas, NM); Walraven, Jeremy A. (Albuquerque, NM); Pimentel, Alejandro A. (Albuquerque, NM)

    2009-04-28T23:59:59.000Z

    A passive voltage contrast (PVC) system and method are disclosed for analyzing ICs to locate defects and failure mechanisms. During analysis a device side of a semiconductor die containing the IC is maintained in an electrically-floating condition without any ground electrical connection while a charged particle beam is scanned over the device side. Secondary particle emission from the device side of the IC is detected to form an image of device features, including electrical vias connected to transistor gates or to other structures in the IC. A difference in image contrast allows the defects or failure mechanisms be pinpointed. Varying the scan rate can, in some instances, produce an image reversal to facilitate precisely locating the defects or failure mechanisms in the IC. The system and method are useful for failure analysis of ICs formed on substrates (e.g. bulk semiconductor substrates and SOI substrates) and other types of structures.

  3. Summary of multiterminal high-voltage direct current transmission technology

    SciTech Connect (OSTI)

    Biggs, R.B.; Jewell, W.T.

    1984-05-01T23:59:59.000Z

    This report summarizes the present state of multiterminal (MT) high-voltage direct current (HVDC) power transmission. The purpose is to reassess the need for HVDC circuit breakers and to identify needed research for MT HVDC. The fundamentals of this technology are presented, and previous research and development is reviewed. Although no MT HVDC systems have yet been built, many concepts have been proposed. Some require a dc breaker, and others do not. Both options have advantages and disadvantages for various applications, so the selection will depend on the proposed application. Research is needed to define operating characteristics of various MT HVDC systems. In some applications, dc breakers will be useful, so research into HVDC interruption should continue. Also, dc fault detection and control algorithms for MT systems should be studied.

  4. PVREG - A photovoltaic voltage regulation investigation tool: Program reference manual

    SciTech Connect (OSTI)

    Garrett, D.L.; Sims, T.R.; Jones, R.A.; Jeter, S.M.

    1989-06-01T23:59:59.000Z

    This manual provides information for installing and maintaining the computer program PVREG, a program developed to study the impact of distributed photovoltaic systems on the voltage regulation of distribution systems. The manual describes installation on the Apollo workstation or the IBM PC-AT (or compatible), but the instructions and code description should be general enough to assist installation on other computers, also. The manual assumes that the user is well acquainted with the computer on which the program is to operate and with the operating system of that computer. The manual describes the program structure and models in detail and provides step-by-step installation instructions for both the Apollo and AT-compatible computers. 9 figs., 11 tabs.

  5. This paper presents a floating slider mechanism to achieve large scanning angular displacements with low voltage

    E-Print Network [OSTI]

    's natural frequency. After a 49% hydrofluoric acid and carbon dioxide LOW -VOLTAGE LARGE ANGULAR: Dual bimorph electrostatic actuator with floating sliders. #12;super-critical point release

  6. Hierarchical Control Scheme for Voltage Harmonics Compensation in an Islanded Droop-

    E-Print Network [OSTI]

    Vasquez, Juan Carlos

    Hierarchical Control Scheme for Voltage Harmonics Compensation in an Islanded Droop- Controlled on the resistance emulation. Furthermore, a droop characteristic based on DG harmonic reactive power has been

  7. Clustering-Based Simultaneous Task and Voltage Scheduling for NoC Systems

    E-Print Network [OSTI]

    Yang, Yu

    2011-08-08T23:59:59.000Z

    -means clustering. (a) cluster assignment. (b) center point moves to the mean of all elements in the cluster. : : : : : : : : : : : 16 4 One iteration in TILE clustering. There are four tiles T1,T2,T3 and T4. Two supply voltages are available. (a) TILE voltage... assignment at the beginning of iteration. (b) T4?s distances to the two voltages are re-evaluated. (c) T4 is assigned to a new voltage according to the re-evaluated distances. : : : : : : : : : : : : : : : : : : : : : : : : : : : 17 5 Comparison...

  8. activated si-gaas high-voltage: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Summary: ??This thesis is concerned with developing a new approach to high voltage transformers condition monitoring, which involve partial discharge (PD) measurement and...

  9. A new technique to reject dc-link voltage ripple in PWM inverters

    E-Print Network [OSTI]

    Shireen, Wajiha

    1990-01-01T23:59:59.000Z

    to acknowledge the support of my husband and parents. TA. BLE OF CONTENTS CHAPTER I INTRODUCTION Page I. l Inverter Power Supplies 1. 2 Output Voltage Control 1. 2. 1 Control Of Voltage Supplied To The Inverter I. 2. 2 Control Of Voltage Within... and output of Stage 3 78 34 Exact solution of the switching angle trajectories for harmonic elimination with voltage control (M). 85 CHAPTER I INTRODUCTION Finding ways to control the flow of electricity has been a. goal of inventors and scientists...

  10. High voltage bus and auxiliary heater control system for an electric or hybrid vehicle

    DOE Patents [OSTI]

    Murty, Balarama Vempaty (West Bloomfield, MI)

    2000-01-01T23:59:59.000Z

    A control system for an electric or hybrid electric vehicle includes a vehicle system controller and a control circuit having an electric immersion heater. The heater is electrically connected to the vehicle's high voltage bus and is thermally coupled to a coolant loop containing a heater core for the vehicle's climate control system. The system controller responds to cabin heat requests from the climate control system by generating a pulse width modulated signal that is used by the control circuit to operate the heater at a duty cycle appropriate for the amount of cabin heating requested. The control system also uses the heater to dissipate excess energy produced by an auxiliary power unit and to provide electric braking when regenerative braking is not desirable and manual braking is not necessary. The control system further utilizes the heater to provide a safe discharge of a bank of energy storage capacitors following disconnection of the battery or one of the high voltage connectors used to transmit high voltage operating power to the various vehicle systems. The control circuit includes a high voltage clamping circuit that monitors the voltage on the bus and operates the heater to clamp down the bus voltage when it exceeds a pre-selected maximum voltage. The control system can also be used to phase in operation of the heater when the bus voltage exceeds a lower threshold voltage and can be used to phase out the auxiliary power unit charging and regenerative braking when the battery becomes fully charged.

  11. Sacramento Area Voltage Support Final Environmental Impact Statement

    SciTech Connect (OSTI)

    N /A

    2003-09-19T23:59:59.000Z

    The Western Area Power Administration's Central Valley Project transmission system forms an integral part of the interconnected Sacramento area transmission grid. Western is contractually responsible to oversee that the system is operated in accordance with strict reliability standards. Growth in the greater Sacramento, California area and power imported from generation outside the region, have increased the demand on the interconnected electric transmission system, leading to transmission system overloads and reducing the reliability and security of the area power system. Western has prepared this Sacramento Area Voltage Support (SVS) Draft Environmental Impact Statement (EIS) in compliance with Federal laws, regulations and guidelines, principally the National Environmental Policy Act (NEPA). This Draft EIS evaluates the potential environmental effects of physical improvements to the area's power system. Enhancements are needed to improve system reliability and provide voltage support for the Sacramento area. The results of public scoping meetings, workshops, meetings with agencies, and earlier studies by Western and area utilities helped to develop a range of alternatives for analysis. The Proposed Action involves: (1) Constructing a new double-circuit, 230-kV transmission line paralleling the existing double-circuit, 230-kV line from the O'Banion Substation to the Elverta Substation; (2) Realigning a portion of the existing Cottonwood-Roseville single-circuit, 230-kV transmission line north of Elverta Substation; and (3) Reconductoring the existing double-circuit, 230-kV transmission line from the Elverta Substation to the Tracy Substation. Public Hearings on the Draft EIS will be held between December 9-12, 2002. Comments on this Draft EIS are encouraged and should be sent to Ms. Loreen McMahon (above). Comments must be received by December 30, 2002.

  12. Sacramento Area Voltage Support Draft Environmental Impact Statement

    SciTech Connect (OSTI)

    N /A

    2002-11-15T23:59:59.000Z

    The Western Area Power Administration's Central Valley Project transmission system forms an integral part of the interconnected Sacramento area transmission grid. Western is contractually responsible to oversee that the system is operated in accordance with strict reliability standards. Growth in the greater Sacramento, California area and power imported from generation outside the region, have increased the demand on the interconnected electric transmission system, leading to transmission system overloads and reducing the reliability and security of the area power system. Western has prepared this Sacramento Area Voltage Support (SVS) Draft Environmental Impact Statement (EIS) in compliance with Federal laws, regulations and guidelines, principally the ''National Environmental Policy Act'' (NEPA). This Draft EIS evaluates the potential environmental effects of physical improvements to the area's power system. Enhancements are needed to improve system reliability and provide voltage support for the Sacramento area. The results of public scoping meetings, workshops, meetings with agencies, and earlier studies by Western and area utilities helped to develop a range of alternatives for analysis. The Proposed Action involves: Constructing a new double-circuit, 230-kV transmission line paralleling the existing double-circuit, 230-kV line from the O'Banion Substation to the Elverta Substation; Realigning a portion of the existing Cottonwood-Roseville single-circuit, 230-kV transmission line north of Elverta Substation; and Reconductoring the existing double-circuit, 230-kV transmission line from the Elverta Substation to the Tracy Substation. Public Hearings on the Draft EIS will be held between December 9-12, 2002. Comments on this Draft EIS are encouraged and should be sent to Ms. Loreen McMahon (above). Comments must be received by December 30, 2002.

  13. T-670: Skype Input Validation Flaw in 'mobile phone' Profile Entry Permits Cross-Site Scripting Attacks

    Broader source: Energy.gov [DOE]

    The software does not properly filter HTML code from user-supplied input in the The "mobile phone" profile entry before displaying the input.

  14. Data error detection and device controller failure detection in an input/output system

    SciTech Connect (OSTI)

    Katzman, J.A.; Bartlett, J.F.; Bixler, R.M.; Davidow, W.H.; Despotakis, J.A.; Graziano, P.J.; Green, M.D.; Greig, D.A.; Hayashi, S.J.; Mackie, D.R.

    1987-06-09T23:59:59.000Z

    This patent describes an input/output system for a multiprocessor system of the kind in which separate processor modules are interconnected for parallel processing, each of the processor modules having a central processing unit and a memory, at least some of the processor modules having an input/output channel, the input/output system comprising, at least one device controller for controlling the transfer of data between multiple different ones of the processor modules and a peripheral device.

  15. Water Power Calculator Temperature and Analog Input/Output Module Ambient Temperature Testing

    SciTech Connect (OSTI)

    Mark D. McKay

    2011-02-01T23:59:59.000Z

    Water Power Calculator Temperature and Analog input/output Module Ambient Temperature Testing A series of three ambient temperature tests were conducted for the Water Power Calculator development using the INL Calibration Laboratory’s Tenney Environmental Chamber. The ambient temperature test results demonstrate that the Moore Industries Temperature Input Modules, Analog Input Module and Analog Output Module, ambient temperature response meet or exceed the manufactures specifications

  16. The SCALE Verified, Archived Library of Inputs and Data - VALID

    SciTech Connect (OSTI)

    Marshall, William BJ J [ORNL] [ORNL; Rearden, Bradley T [ORNL] [ORNL

    2013-01-01T23:59:59.000Z

    The Verified, Archived Library of Inputs and Data (VALID) at ORNL contains high quality, independently reviewed models and results that improve confidence in analysis. VALID is developed and maintained according to a procedure of the SCALE quality assurance (QA) plan. This paper reviews the origins of the procedure and its intended purpose, the philosophy of the procedure, some highlights of its implementation, and the future of the procedure and associated VALID library. The original focus of the procedure was the generation of high-quality models that could be archived at ORNL and applied to many studies. The review process associated with model generation minimized the chances of errors in these archived models. Subsequently, the scope of the library and procedure was expanded to provide high quality, reviewed sensitivity data files for deployment through the International Handbook of Evaluated Criticality Safety Benchmark Experiments (IHECSBE). Sensitivity data files for approximately 400 such models are currently available. The VALID procedure and library continue fulfilling these multiple roles. The VALID procedure is based on the quality assurance principles of ISO 9001 and nuclear safety analysis. Some of these key concepts include: independent generation and review of information, generation and review by qualified individuals, use of appropriate references for design data and documentation, and retrievability of the models, results, and documentation associated with entries in the library. Some highlights of the detailed procedure are discussed to provide background on its implementation and to indicate limitations of data extracted from VALID for use by the broader community. Specifically, external users of data generated within VALID must take responsibility for ensuring that the files are used within the QA framework of their organization and that use is appropriate. The future plans for the VALID library include expansion to include additional experiments from the IHECSBE, to include experiments from areas beyond criticality safety, such as reactor physics and shielding, and to include application models. In the future, external SCALE users may also obtain qualification under the VALID procedure and be involved in expanding the library. The VALID library provides a pathway for the criticality safety community to leverage modeling and analysis expertise at ORNL.

  17. SRTC input to DOE-HQ R and D database for FY99

    SciTech Connect (OSTI)

    Chandler, L.R. Jr.

    2000-01-05T23:59:59.000Z

    This is a database of the Savannah River Site input to the DOE Research and Development database. The report contains approximately 50 project abstracts.

  18. V-112: Microsoft SharePoint Input Validation Flaws Permit Cross...

    Broader source: Energy.gov (indexed) [DOE]

    update addresses the vulnerabilities correcting the way that Microsoft SharePoint Server validates URLs and user input. IMPACT: A remote user can cause denial of service...

  19. PREDICTING THE TIME RESPONSE OF A BUILDING UNDER HEAT INPUT CONDITIONS FOR ACTIVE SOLAR HEATING SYSTEMS

    E-Print Network [OSTI]

    Warren, Mashuri L.

    2013-01-01T23:59:59.000Z

    Solar Energy Systems for Heating and Cooling. May, 1978. (Washington:Hemisphere heating, Publishing Corp. , 1978),INPUT CONDITIONS FOR ACTIVE SOLAR HEATING SYSTEMS Mashuri L.

  20. Approaches used for Clearance of Lands from Nuclear Facilities among Several Countries: Evaluation for Regulatory Input

    Broader source: Energy.gov [DOE]

    The study entitled, “Approaches used for Clearance of Lands from Nuclear Facilities among Several Countries: Evaluation for Regulatory Input,” focuses on the issue of showing compliance with given...

  1. [Composite analysis E-area vaults and saltstone disposal facilities]. PORFLOW and FACT input files

    SciTech Connect (OSTI)

    Cook, J.R.

    1997-09-01T23:59:59.000Z

    This diskette contains the PORFLOW and FACT input files described in Appendix B of the accompanying report `Composite Analysis E-Area Vaults and Saltstone Disposal Facilities`.

  2. Chapter 19. High Voltage Insulation, Diagnostics and Energetic Electron and Photon Beam Interactions

    E-Print Network [OSTI]

    Chapter 19. High Voltage Insulation, Diagnostics and Energetic Electron and Photon Beam Interactions 19-1 High Voltage Insulation, Diagnostics and Energetic Electron and Photon Beam Interactions 1. DC Properties of Modern Filled Epoxy Insulation Academic and Research Staff Dr. Chathan Cooke Sponsor

  3. Public Opinions of Building Additional High-Voltage Electric Power Lines

    E-Print Network [OSTI]

    Tesfatsion, Leigh

    Public Opinions of Building Additional High-Voltage Electric Power Lines A Report to the National-Voltage Electric Power Lines: A Report to the National Science Foundation and the Electric Power Research Center to build new power lines. Residents living in counties with planned routes for new transmission lines

  4. Wind Farm Reactive Support and Voltage Control Daniel F. Opila Abdi M. Zeynu Ian A. Hiskens

    E-Print Network [OSTI]

    Hiskens, Ian A.

    Wind Farm Reactive Support and Voltage Control Daniel F. Opila Abdi M. Zeynu Ian A. Hiskens Abstract--Wind farms typically contain a variety of voltage control equipment including tap or wind farm; it is desirable to treat all the equipment as an integrated system rather than independent

  5. High voltage transformers. (Latest citations from the Inspec database). NewSearch

    SciTech Connect (OSTI)

    Not Available

    1994-11-01T23:59:59.000Z

    The bibliography contains citations concerning materials and performance of insulators used for high voltage transformers. Topics examine use of mica-fibers, gases, mica filled epoxies, and ceramics. Effects of insulation aging are reviewed, and acceptance testing of high voltage power transformers and apparatus is also examined. (Contains a minimum of 104 citations and includes a subject term index and title list.)

  6. High voltage transformers. (Latest citations from the US Patent bibliographic file with exemplary claims). Published Search

    SciTech Connect (OSTI)

    NONE

    1996-08-01T23:59:59.000Z

    The bibliography contains citations of selected patents concerning high voltage transformers. Included are hybrid, video, rectifier, x-ray diagnostic generator, temperature control system, and printed circuit wound high voltage transformers. The fabrication, assembly, and testing of these transformers are also presented. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  7. High voltage transformers. (Latest citations from the US Patent bibliographic file with exemplary claims). Published Search

    SciTech Connect (OSTI)

    NONE

    1995-07-01T23:59:59.000Z

    The bibliography contains citations of selected patents concerning high voltage transformers. Included are hybrid, video, rectifier, x-ray diagnostic generator, temperature control system, and printed circuit wound high voltage transformers. The fabrication, assembly, and testing of these transformers are also presented. (Contains 50-250 citations and includes a subject term index and title list.)

  8. Reactive Power Sharing and Voltage Harmonic Distortion Compensation of Droop Controlled

    E-Print Network [OSTI]

    Vasquez, Juan Carlos

    1 Reactive Power Sharing and Voltage Harmonic Distortion Compensation of Droop Controlled Single, the inverters typically employ the droop control scheme. Traditional droop control enables the decentralized regulation of the local voltage and frequency of the microgrid by the inverters. The droop method also

  9. Figure 1. Voltage margins to manage fluctuations. AUDIT: Stress Testing the Automatic Way

    E-Print Network [OSTI]

    John, Lizy Kurian

    .govindan}@amd.com Abstract--Sudden variations in current (large di/dt) can lead to significant power supply voltage droops; stressmark generation; voltage droop; power distribution network; low power; genetic algorithm; hardware][12][13]. Other work addressed mitigating droops that occur due to various architectural events [3

  10. A Voltage Controlled Nano Addressing Circuit University of Texas, San Antonio TX 78249, USA,

    E-Print Network [OSTI]

    Liu, Bao

    A Voltage Controlled Nano Addressing Circuit Bao Liu University of Texas, San Antonio TX 78249, USA, Abstract. A voltage controlled nano addressing circuit is proposed, which (1) improves yield and enables aggressive scaling with no require- ment of precise layout design, (2) achieves precision of addressing

  11. Journal of Power Sources 167 (2007) 1117 Voltage reversal during microbial fuel cell stack operation

    E-Print Network [OSTI]

    2007-01-01T23:59:59.000Z

    Journal of Power Sources 167 (2007) 11­17 Voltage reversal during microbial fuel cell stack February 2007; accepted 9 February 2007 Available online 20 February 2007 Abstract Microbial fuel cells Elsevier B.V. All rights reserved. Keywords: Microbial fuel cell; Voltage reversal; Stack; Direct electron

  12. A New Bifurcation Analysis for Power System Dynamic Voltage Stability Studies

    E-Print Network [OSTI]

    a specific system configuration and the operation condition. For a power system, the typical state variables are the time dependent generator voltages (For different generator models, the variables of generator voltages as the variables of the exciter, speed governor and so on; sometimes the dynamics of the load behavior will also

  13. Impact of High Wind Penetration on the Voltage Profile of Distribution Systems

    E-Print Network [OSTI]

    Pota, Himanshu Roy

    of wind generator the voltage of the system may become lower than acceptable voltage level due and wind generator is presented. Simulation results are given in Section III which shows the impact of high--In this paper, simulation results showing the effect of lower and higher penetration of distributed wind

  14. An Ensemble Empirical Mode Decomposition Approach for Voltage Sag Detection in a Smart Grid Context

    E-Print Network [OSTI]

    Brest, Université de

    An Ensemble Empirical Mode Decomposition Approach for Voltage Sag Detection in a Smart Grid Context Yassine Amirat1,2 , Mohamed Benbouzid2 , Tianzhen Wang3 and Sylvie Turri2 Abstract­Smart grids have become, using the instantaneous power for voltage sags detection in smart grids. Copyright © 2013 Praise Worthy

  15. A LOW POWER SCHEDULING SCHEME WITH RESOURCES OPERATING AT MULTIPLE VOLTAGES

    E-Print Network [OSTI]

    Kambhampati, Subbarao

    A LOW POWER SCHEDULING SCHEME WITH RESOURCES OPERATING AT MULTIPLE VOLTAGES Ali Manzak and Chaitali Tempe, AZ 85287­5706 istanbul@asu.edu, chaitali@asu.edu ABSTRACT This paper presents a new resource the resources operate at multi­ ple voltages. The scheduling scheme is list based. In each control cycle

  16. Supply Voltage Degradation Aware Analytical Placement Andrew B. Kahng Bao Liu Qinke Wang

    E-Print Network [OSTI]

    Liu, Bao

    Supply Voltage Degradation Aware Analytical Placement Andrew B. Kahng Bao Liu Qinke Wang Computer@cs.ucsd.edu} Abstract Increasingly significant power/ground supply voltage degradation in nanometer VLSI designs leads to system per- formance degradation and even malfunction. Existing tech- niques focus on design

  17. Voltage Control of Distribution Networks with Distributed Generation using Reactive Power

    E-Print Network [OSTI]

    Pota, Himanshu Roy

    Voltage Control of Distribution Networks with Distributed Generation using Reactive Power to control voltage of distribution networks with DG using reactive power compensation approach. In this paper profile within the specified limits, it is essential to regulate the reactive power of the compensators

  18. Supervisory hybrid model predictive control for voltage stability of power networks

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Supervisory hybrid model predictive control for voltage stability of power networks R.R. Negenborn voltage control problems in electric power networks have stimulated the interest for the imple- mentation dynamics to restore power consumption beyond the capability of the transmission and generation system

  19. Pipeline Strategy for Improving Optimal Energy Efficiency in Ultra-Low Voltage Design

    E-Print Network [OSTI]

    Kambhampati, Subbarao

    Pipeline Strategy for Improving Optimal Energy Efficiency in Ultra-Low Voltage Design Mingoo Seok for the ultra low voltage regime. Based on an analytical model and simulations, we propose a pipelining technique that provides higher energy effi- ciency and performance than conventional approaches to ultra low

  20. Variation-aware Clock Network Design Methodology for Ultra-Low Voltage (ULV) Circuits

    E-Print Network [OSTI]

    Lim, Sung Kyu

    Variation-aware Clock Network Design Methodology for Ultra-Low Voltage (ULV) Circuits Xin Zhao networks for ultra-low voltage (ULV) circuits. We show that both clock slew and skew play important roles) at comparable or even higher Fmax compared with the existing methods. Keywords--clock network design, ultra-low

  1. Mitigation of Voltage and Current Harmonics in Grid-Connected Microgrids

    E-Print Network [OSTI]

    Vasquez, Juan Carlos

    Mitigation of Voltage and Current Harmonics in Grid-Connected Microgrids Mehdi Savaghebi1 , Josep M-connected microgrids. Two modes of compensation are considered, i.e. voltage and current compensation modes-electronic interface converter to the utility grid or microgrid. Microgrid is a local grid consisting of DGs, energy

  2. Radio-frequency powered glow discharge device and method with high voltage interface

    DOE Patents [OSTI]

    Duckworth, Douglas C. (Knoxville, TN); Marcus, R. Kenneth (Clemson, SC); Donohue, David L. (Vienna, AT); Lewis, Trousdale A. (Oak Ridge, TN)

    1994-01-01T23:59:59.000Z

    A high voltage accelerating potential, which is supplied by a high voltage direct current power supply, is applied to the electrically conducting interior wall of an RF powered glow discharge cell. The RF power supply desirably is electrically grounded, and the conductor carrying the RF power to the sample held by the probe is desirably shielded completely excepting only the conductor's terminal point of contact with the sample. The high voltage DC accelerating potential is not supplied to the sample. A high voltage capacitance is electrically connected in series between the sample on the one hand and the RF power supply and an impedance matching network on the other hand. The high voltage capacitance isolates the high DC voltage from the RF electronics, while the RF potential is passed across the high voltage capacitance to the plasma. An inductor protects at least the RF power supply, and desirably the impedance matching network as well, from a short that might occur across the high voltage capacitance. The discharge cell and the probe which holds the sample are configured and disposed to prevent the probe's components, which are maintained at ground potential, from bridging between the relatively low vacuum region in communication with the glow discharge maintained within the cell on the one hand, and the relatively high vacuum region surrounding the probe and cell on the other hand. The probe and cell also are configured and disposed to prevent the probe's components from electrically shorting the cell's components.

  3. Radio-frequency powered glow discharge device and method with high voltage interface

    DOE Patents [OSTI]

    Duckworth, D.C.; Marcus, R.K.; Donohue, D.L.; Lewis, T.A.

    1994-06-28T23:59:59.000Z

    A high voltage accelerating potential, which is supplied by a high voltage direct current power supply, is applied to the electrically conducting interior wall of an RF powered glow discharge cell. The RF power supply desirably is electrically grounded, and the conductor carrying the RF power to the sample held by the probe is desirably shielded completely excepting only the conductor's terminal point of contact with the sample. The high voltage DC accelerating potential is not supplied to the sample. A high voltage capacitance is electrically connected in series between the sample on the one hand and the RF power supply and an impedance matching network on the other hand. The high voltage capacitance isolates the high DC voltage from the RF electronics, while the RF potential is passed across the high voltage capacitance to the plasma. An inductor protects at least the RF power supply, and desirably the impedance matching network as well, from a short that might occur across the high voltage capacitance. The discharge cell and the probe which holds the sample are configured and disposed to prevent the probe's components, which are maintained at ground potential, from bridging between the relatively low vacuum region in communication with the glow discharge maintained within the cell on the one hand, and the relatively high vacuum region surrounding the probe and cell on the other hand. The probe and cell also are configured and disposed to prevent the probe's components from electrically shorting the cell's components. 11 figures.

  4. Low Power Discrete Voltage Assignment Under Clock Skew , Jian Sun2

    E-Print Network [OSTI]

    Zhou, Hai

    assignment problem by formulating it into an Integer Linear Programming (ILP) with inequalities representingLow Power Discrete Voltage Assignment Under Clock Skew Scheduling Li Li1 , Jian Sun2 , Yinghai Lu1 Abstract--Multiple Supply Voltage (MSV) assignment has emerged as an appealing technique in low power IC

  5. Importance of the Equlibrium Node in Preventing the Voltage Collapse Occurs in the Wind Power System

    E-Print Network [OSTI]

    Lavaei, Javad

    Importance of the Equlibrium Node in Preventing the Voltage Collapse Occurs in the Wind Power collapse will occurs in a wind power system is discussed next. The method of power flow calculation is the specific analysis of a given simplified wind power system. Keywords--voltage collapse; Newton

  6. TCSC as a Transient Voltage Stabilizing Controller Garng Huang and Tong Zhu

    E-Print Network [OSTI]

    to enhance the voltage stability by changing the reactive power distribution in the power system. Authors and operated by some utilities [1,2]. The primary uses of TCSC are to enhance the power system angle stability on the small signal voltage stability for a simple power system with an infinitive bus and a dynamic load

  7. A Two-Stage Distributed Architecture for Voltage Control in Power Distribution Systems

    E-Print Network [OSTI]

    Hadjicostis, Christoforos

    violations and shapes the voltage profile in radial distribution networks, even in the presence [6]--and the Equinox house [7] are examples of residential PV installations capable of producing, the additional power demand introduced by massive charging of PHEVs can potentially cause unacceptable voltage

  8. VOLTAGE COLLAPSE AND TRANSIENT ENERGY FUNCTION ANALYSES OF AC/DC SYSTEMS

    E-Print Network [OSTI]

    Cañizares, Claudio A.

    for power system dynamic models, including a third order representation of high voltage direct current (HVDC power limits, HVDC firing angle limits and voltage dependent current order limits (VDCOL) are shown the derivation of individual component Lyapunov functions for simplified models of HVDC links connected

  9. Voltage grid support of DFIG wind turbines during grid faults Anca D. Hansen1

    E-Print Network [OSTI]

    Voltage grid support of DFIG wind turbines during grid faults Anca D. Hansen1 , Gabriele Michalke2 Abstract The fault ride-through and grid support capabilities of the doubly fed induction generator (DFIG and their contribution to support the grid, i.e. to the voltage control in the power system, during grid faults

  10. A New Thermal-Conscious System-Level Methodology for Energy-Efficient Processor Voltage Selection

    E-Print Network [OSTI]

    Wang, Yu

    A New Thermal-Conscious System-Level Methodology for Energy-Efficient Processor Voltage Selection a thermal-conscious system-level methodology to make energy-efficient voltage selection (VS) for nanometer), thermal resistance, are integrated and considered in our system models, and their impacts on energy

  11. Low-profile high-voltage compact gas switch

    SciTech Connect (OSTI)

    Goerz, D.A.; Wilson, M.J.; Speer, R.D.

    1997-06-30T23:59:59.000Z

    This paper discusses the development and testing of a low-profile, high-voltage, spark-gap switch designed to be closely coupled with other components into an integrated high-energy pulsed-power source. The switch is designed to operate at 100 kV using SF6 gas pressurized to less than 0.7 MPa. The volume of the switch cavity region is less than 1.5 cm3, and the field stress along the gas-dielectric interface is as high as 130 kV/cm. The dielectric switch body has a low profile that is only I -cm tall at its greatest extent and nominally 2-mm thick over most of its area. This design achieves a very low inductance of less than 5 nH, but results in field stresses exceeding 500 kV/cm in the dielectric material. Field modeling was done to determine the appropriate shape for the highly stressed insulator and electrodes, and special manufacturing techniques were employed to mitigate the usual mechanisms that induce breakdown and failure in solid dielectrics. Static breakdown tests verified that the switch operates satisfactorily at 100 kV levels. The unit has been characterized with different shaped electrodes having nominal gap spacings of 2.0, 2.5, and 3.0 mm. The relationship between self-break voltage and operating pressure agrees well with published data on gas properties, accounting for the field enhancements of the electrode shapes being used. Capacitor discharge tests in a low inductance test fixture exhibited peak currents up to 25 kA with characteristic frequencies of the ringdown circuit ranging from 10 to 20 MHz. The ringdown waveforms and scaling of measured parameters agree well with circuit modeling of the switch and test fixture. Repetitive operation has been demonstrated at moderate rep-rates up to 15 Hz, limited by the power supply being used. Preliminary tests to evaluate lifetime of the compact switch assembly have been encouraging. In one case, after more than 7,000 high-current ringdown tests with approximately 30 C of total charge transferred, the switch continued to operate satisfactorily with no apparent tracking or deterioration of the insulator.

  12. Switch contact device for interrupting high current, high voltage, AC and DC circuits

    DOE Patents [OSTI]

    Via, Lester C.; Witherspoon, F. Douglas; Ryan, John M.

    2005-01-04T23:59:59.000Z

    A high voltage switch contact structure capable of interrupting high voltage, high current AC and DC circuits. The contact structure confines the arc created when contacts open to the thin area between two insulating surfaces in intimate contact. This forces the arc into the shape of a thin sheet which loses heat energy far more rapidly than an arc column having a circular cross-section. These high heat losses require a dramatic increase in the voltage required to maintain the arc, thus extinguishing it when the required voltage exceeds the available voltage. The arc extinguishing process with this invention is not dependent on the occurrence of a current zero crossing and, consequently, is capable of rapidly interrupting both AC and DC circuits. The contact structure achieves its high performance without the use of sulfur hexafluoride.

  13. Low Voltage High Precision Spatial Light ModulatorsFinal Report

    SciTech Connect (OSTI)

    Papavasiliou, A P

    2005-02-09T23:59:59.000Z

    The goal of this project was to make LLNL a leader in Spatial Light Modulators (SLMs) by developing the technology that will be needed by the next generation of SLMs. We would use new lower voltage actuators and bond those actuators directly to controlling circuitry to break the fundamental limitations that constrain current SLM technology. This three-year project was underfunded in the first year and not funded in the second year. With the funding that was available, we produced actuators and designs for the controlling circuitry that would have been integrated in the second year. Spatial light modulators (SLMs) are arrays of tiny movable mirrors that modulate the wave-fronts of light. SLMs can correct aberrations in incoming light for adaptive optics or modulate light for beam control, optical communication and particle manipulation. MicroElectroMechanical Systems (MEMS) is a technology that utilizes the microfabrication tools developed by the semiconductor industry to fabricate a wide variety of tiny machines. The first generation of MEMS SLMs have improved the functionality of SLMs while drastically reducing per pixel cost making arrays on the order of 1000 pixels readily available. These MEMS SLMs however are limited by the nature of their designs to be very difficult to scale above 1000 pixels and have very limited positioning accuracy. By co-locating the MEMS mirrors with CMOS electronics, we will increase the scalability and positioning accuracy. To do this we will have to make substantial advances in SLM actuator design, and fabrication.

  14. High voltage power supply with modular series resonant inverters

    DOE Patents [OSTI]

    Dreifuerst, G.R.; Merritt, B.T.

    1995-07-18T23:59:59.000Z

    A relatively small and compact high voltage, high current power supply for a laser utilizes a plurality of modules containing series resonant half bridge inverters. A pair of reverse conducting thyristors are incorporated in each series resonant inverter module such that the series resonant inverter modules are sequentially activated in phases 360{degree}/n apart, where n=number of modules for n>2. Selective activation of the modules allows precise output control reducing ripple and improving efficiency. Each series resonant half bridge inverter module includes a transformer which has a cooling manifold for actively circulating a coolant such as water, to cool the transformer core as well as selected circuit elements. Conductors connecting and forming various circuit components comprise hollow, electrically conductive tubes such as copper. Coolant circulates through the tubes to remove heat. The conductive tubes act as electrically conductive lines for connecting various components of the power supply. Where it is desired to make electrical isolation breaks, tubes comprised of insulating material such as nylon are used to provide insulation and continue the fluid circuit. 11 figs.

  15. High voltage power supply with modular series resonant inverters

    DOE Patents [OSTI]

    Dreifuerst, Gary R. (Livermore, CA); Merritt, Bernard T. (Livermore, CA)

    1995-01-01T23:59:59.000Z

    A relatively small and compact high voltage, high current power supply for a laser utilizes a plurality of modules containing series resonant half bridge inverters. A pair of reverse conducting thyristors are incorporated in each series resonant inverter module such that the series resonant inverter modules are sequentially activated in phases 360.degree./n apart, where n=number of modules for n>2. Selective activation of the modules allows precise output control reducing ripple and improving efficiency. Each series resonant half bridge inverter module includes a transformer which has a cooling manifold for actively circulating a coolant such as water, to cool the transformer core as well as selected circuit elements. Conductors connecting and forming various circuit components comprise hollow, electrically conductive tubes such as copper. Coolant circulates through the tubes to remove heat. The conductive tubes act as electrically conductive lines for connecting various components of the power supply. Where it is desired to make electrical isolation breaks, tubes comprised of insulating material such as nylon are used to provide insulation and continue the fluid circuit.

  16. FLEX AND PINCH: A CASE STUDY OF WHOLE HAND INPUT DESIGN FOR VIRTUAL ENVIRONMENT INTERACTION

    E-Print Network [OSTI]

    Pattanaik, Sumanta N.

    FLEX AND PINCH: A CASE STUDY OF WHOLE HAND INPUT DESIGN FOR VIRTUAL ENVIRONMENT INTERACTION JOSEPH J. LAVIOLA JR. and ROBERT C. ZELEZNIK Brown University Site of the NSF Science and Technology Center. In this paper, we describe our Pinch Glove like input device which is used as a tool to augment bend

  17. Noninvasive high-resolution detection of the arterial and venous input function through a PET Wrist

    E-Print Network [OSTI]

    Noninvasive high-resolution detection of the arterial and venous input function through a PET Wrist using planar coincidence images. I. INTRODUCTION Quantitative Positron Emission Tomography (PET) often determine the input function. These techniques include external monitors and PET scanners that measure

  18. Improved Imaged-derived Input Function for Study of Human Brain FDG-PET

    E-Print Network [OSTI]

    Renaut, Rosemary

    Improved Imaged-derived Input Function for Study of Human Brain FDG-PET Hongbin Guo, Rosemary tomography (PET) studies. Two time windows can be recognized in the time activity curve measured from the compartmental model for FDG PET [5]. Index Terms Quantification of FDG PET, Automated Image-derived input

  19. Evaluating an Alternative Model for the Input Function in FDG-PET Studies 1

    E-Print Network [OSTI]

    Renaut, Rosemary

    Evaluating an Alternative Model for the Input Function in FDG-PET Studies 1 Hongbin Guo 2 Rosemary-D-glucose flu- oro (FDG) positron emission tomography (PET) brain studies with bolus injection is presented-derived expressions. The new model provides an effective means to recover the input function in FDG-PET studies

  20. Experimental Results on Multiple-Input Single-Output (MISO) Time Reversal for UWB

    E-Print Network [OSTI]

    Qiu, Robert Caiming

    Experimental Results on Multiple-Input Single-Output (MISO) Time Reversal for UWB Systems with multiple-input single- output (MISO) antennas over ultra-wideband (UWB) channels. In particular, temporal and spatial focusing as well as array gain are studied based on a (4 × 1) MISO scheme in an office environment

  1. Design of penalty functions for optimal control of linear dynamical systems under state and input constraints

    E-Print Network [OSTI]

    Design of penalty functions for optimal control of linear dynamical systems under state and input of solving a constrained optimal control for a general single-input single output linear time varying system dimensional (functional optimization) case. The main novelty is that both the bounds on the control variable

  2. Asymptotic Controllability and Input-to-State Stabilization: The Effect of Actuator Errors

    E-Print Network [OSTI]

    Sontag, Eduardo

    a new feedback design that makes globally asymptotically controllable systems input-to-state stable of input-to-state stable (ISS) systems forms the basis for much modern nonlinear feedback design-to-state stabi- lizability of nonlinear finite-dimensional continuous-time control systems. We focus on some

  3. Kalman filtering with unknown inputs via optimal state estimation of singular systems

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    1 Kalman filtering with unknown inputs via optimal state estimation of singular systems M. DAROUACH de Lorraine, 54400 COSNES ET ROMAIN, FRANCE A new method for designing a Kalman filter for linear the Kalman filter, it is generally assumed that all system parameters, noise covariances, and inputs

  4. INPUT VARIABLE SELECTION USING INDEPENDENT COMPONENT ANALYSIS AND HIGHER ORDER STATISTICS

    E-Print Network [OSTI]

    Vialatte, François

    that the method is capable of giving reliable performance with dependent inputs to non- linear models. 1-test. Given a linear regression model (1) where is an parameter vector and is an input regression vector. Assume we have a generating system given by (2) where and is some static non- linear function, possibly

  5. A coupled isotope tracer method to characterize input water to lakes

    E-Print Network [OSTI]

    Edwards, Thomas W.D.

    of input waters after accounting for the effects of secondary evaporative isotopic enrichment. As shownA coupled isotope tracer method to characterize input water to lakes Yi Yi a,*, Bronwyn E. Brock in revised form 7 November 2007; accepted 9 November 2007 KEYWORDS Water isotope tracers; Isotope hydrology

  6. Magnetized Target Fusion: Input to the 35-yr Fusion Long-Range Electric Plan

    E-Print Network [OSTI]

    controlled thermonuclear fusion in the laboratory -- Intermediate between MFE and IFE · Presently only fundedMagnetized Target Fusion: Input to the 35-yr Fusion Long-Range Electric Plan G. A. Wurden Fusion Energy Program Office Los Alamos National Laboratory Jan. 14, 2003 #12;Magnetized Target Fusion: Input

  7. A Current-based Method for Short Circuit Power Calculation under Noisy Input Waveforms*

    E-Print Network [OSTI]

    Pedram, Massoud

    A Current-based Method for Short Circuit Power Calculation under Noisy Input Waveforms* Hanif circuit energy dissipation of logic cells. The short circuit current is highly dependent on the input waveforms are then used to calculate the short circuit current, and hence, short circuit energy dissipation

  8. 2008 Residential Building Efficiency Standards 1 Efficiency Ratings and Performance Modeling Inputs

    E-Print Network [OSTI]

    Inputs for the Daiken AC (Americas), Inc. Altherma Air-to-Water Source Heat Pump System The Building-to-Water Source Heat Pump can provide space heating, space cooling and domestic water heating functions Required Compliance Software Inputs-- The Altherma Air-to-Water Source Heat Pump system is an electric heat

  9. LETTER Communicated by Emilio Salinas Higher-Order Statistics of Input Ensembles and the Response

    E-Print Network [OSTI]

    LETTER Communicated by Emilio Salinas Higher-Order Statistics of Input Ensembles and the Response (Steinmetz et al., 2000; Salinas & Sejnowski, 2001). The effect of correlated synaptic input on the neuronal; Salinas & Sejnowski, 2000; Svirskis & Rinzel, 2000; Feng & Zhang, 2001; Stroeve & Gielen, 2001

  10. MiTV: Multiple-Implementation Testing of User-Input Validators for Web Applications

    E-Print Network [OSTI]

    Xie, Tao

    MiTV: Multiple-Implementation Testing of User-Input Validators for Web Applications Kunal Taneja1 Nuo Li1 Madhuri R. Marri1 Tao Xie1 Nikolai Tillmann2 1 Department of Computer Science, North Carolina,txie}@ncsu.edu, 2nikolait@microsoft.com ABSTRACT User-input validators play an essential role in guarding a web

  11. Quality assurance of solar thermal systems with the ISFH-Input/Output-Procedure

    E-Print Network [OSTI]

    Quality assurance of solar thermal systems with the ISFH- Input/Output-Procedure Peter Paerisch different solar systems. The simulation model was validated with measured data. The deviation between meas * Tel. +49 (0)5151-999503, Fax: +49 (0)5151-999500, Email: paerisch@isfh.de Abstract Input/Output

  12. Review of input stages used in front end electronics for particle detectors

    E-Print Network [OSTI]

    Kaplon, J

    2015-01-01T23:59:59.000Z

    In this paper we present noise analysis of the input stages most commonly used in front end electronics for particle detectors. Analysis shows the calculation of the input referenced noise related to the active devices. It identifies the type, parallel or series, of the equivalent noise sources related to the input transistors, which is the important input for the further choice of the signal processing method. Moreover we calculate the input impedance of amplifiers employed in applications where the particle detector is connected to readout electronics by means of transmission line. We present schematics, small signal models,a complete set of equations, and results of the major steps of calculations for all discussed circuits.

  13. An Annotated Bibliography of High-Voltage Direct-Current Transmission and Flexible AC Transmission (FACTS) Devices, 1991-1993.

    SciTech Connect (OSTI)

    Litzenberger, Wayne; Lava, Val

    1994-08-01T23:59:59.000Z

    References are contained for HVDC systems, converter stations and components, overhead transmission lines, cable transmission, system design and operations, simulation of high voltage direct current systems, high-voltage direct current installations, and flexible AC transmission system (FACTS).

  14. Source of Sustained Voltage Difference between the Xylem of a Potted Ficus benjamina Tree and Its Soil

    E-Print Network [OSTI]

    Mershin, Andreas

    It has long been known that there is a sustained electrical potential (voltage) difference between the xylem of many plants

  15. 130kV 130A High Voltage Switching Mode Power Supply for Neutral Injections – Control Issues and Algorithms

    E-Print Network [OSTI]

    130kV 130A High Voltage Switching Mode Power Supply for Neutral Injections – Control Issues and Algorithms

  16. Princeton Power Systems (TRL 5 6 Component)- Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage

    Broader source: Energy.gov [DOE]

    Princeton Power Systems (TRL 5 6 Component) - Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage

  17. Clustering-Based Simultaneous Task and Voltage Scheduling for NoC Systems 

    E-Print Network [OSTI]

    Yang, Yu

    2011-08-08T23:59:59.000Z

    - dress the voltage-frequency assignment problem for NoC. In [8], the voltage-frequency assignment and partitioning were performed after the tasks were bound to PEs and mapped to tiles. The whole procedure can be divided into two separate parts: first..., and the cluster agglomeration procedure. In the experiment, we compare our method with a sequential approach of task schedul- ing followed by voltage assignment [12]. The results show that our method can achieve 20% energy reduction on average under the same...

  18. Characteristics of probe current harmonics based on various applied voltage waveforms in low temperature plasmas

    SciTech Connect (OSTI)

    Kim, Young-Do; Kim, Yu-Sin; Lee, Hyo-Chang; Bang, Jin-Young; Chung, Chin-Wook [Department of Electrical Engineering, Hanyang University, 17 Heangdang-dong, Seongdong-gu, Seoul 133-791 (Korea, Republic of)

    2011-03-15T23:59:59.000Z

    The characteristics of probe currents induced by applying various probe voltage waveforms, such as sinusoidal, sawtooth, square, and triangular, were investigated at a floating potential. It was found that the measured probe currents have many harmonics depending on the voltage waveforms. This was mainly due to the nonlinearity of the sheath in the plasma and was analyzed using the fast Fourier transform and a circuit model. By applying a triangular voltage waveform to a probe, plasma parameters such as electron temperature and plasma density could be obtained and compared to those of a single Langmuir probe and a floating harmonic method.

  19. High Power, High Voltage FETs in Linear Applications: A User's Perspective

    SciTech Connect (OSTI)

    N. Greenough, E. Fredd, S. DePasquale

    2009-09-21T23:59:59.000Z

    The specifications of the current crop of highpower, high-voltage field-effect transistors (FETs) can lure a designer into employing them in high-voltage DC equipment. Devices with extremely low on-resistance and very high power ratings are available from several manufacturers. However, our experience shows that high-voltage, linear operation of these devices at near-continuous duty can present difficult reliability challenges at stress levels well-below their published specifications. This paper chronicles the design evolution of a 600 volt, 8 ampere shunt regulator for use with megawatt-class radio transmitters, and presents a final design that has met its reliability criteria.

  20. Further investigation of electronic multiplication of voltages by use of logarithms

    E-Print Network [OSTI]

    Biard, James Robert

    1957-01-01T23:59:59.000Z

    efficient use of the maximum power ratings of the output tube or power supplies. When the positive feedback in this amplifier is properly adjusted, infinite gain results at DC. That is, the voltage between control grid and ground does not vary for a... change in output voltage. Since the control grid remains at ground po? tential, any change in output must be due to a change in cathode-to-ground voltage. The proper bias for the pentode screen is obtained with a resistive divider from B+ to a point...