Powered by Deep Web Technologies
Note: This page contains sample records for the topic "injection dsi systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Denmark Solar Industry DSI | Open Energy Information  

Open Energy Info (EERE)

Industry DSI Industry DSI Jump to: navigation, search Name Denmark Solar Industry (DSI) Place Copenhagen, Denmark Zip DK-1550 Sector Solar Product Manufactures and distributes solar panels and systems. Coordinates 55.67631°, 12.569355° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":55.67631,"lon":12.569355,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

2

DSI Dipole Shear Sonic Imager | Open Energy Information  

Open Energy Info (EERE)

2013 DOI Not Provided Check for DOI availability: http:crossref.org Online Internet link for DSI Dipole Shear Sonic Imager Citation Schlumberger. DSI Dipole Shear Sonic...

3

Dry Integrated Emissions Control Technology Options: EMO, DryFining, NeuStream-DR and DSI State-of-the-Art  

Science Conference Proceedings (OSTI)

This Electric Power Research Institute (EPRI) technical update provides a series of enhanced Level 1 analyses of multiple dry integrated emissions reduction technology options for use at coal-fired, utility-scale generating plants. The report also contains a section covering the current state-of-the-art for Duct Sorbent Injection systems (DSI). This document also includes an updated listing of the Integrated Emissions Control (IEC) technologies that have been proposed in the past for use at ...

2013-12-21T23:59:59.000Z

4

THE RHIC INJECTION SYSTEM.  

SciTech Connect

The RHIC injection system has to transport beam from the AGS-to-RHIC transfer line onto the closed orbits of the RHIC Blue and Yellow rings. This task can be divided into three problems. First, the beam has to be injected into either ring. Second, once injected the beam needs to be transported around the ring for one turn. Third, the orbit must be closed and coherent beam oscillations around the closed orbit should be minimized. We describe our solutions for these problems and report on system tests conducted during the RHIC Sextant test performed in 1997. The system will be fully commissioned in 1999.

FISCHER,W.; GLENN,J.W.; MACKAY,W.W.; PTITSIN,V.; ROBINSON,T.G.; TSOUPAS,N.

1999-03-29T23:59:59.000Z

5

Pages that link to "Denmark Solar Industry DSI" | Open Energy...  

Open Energy Info (EERE)

250 | 500) Retrieved from "http:en.openei.orgwikiSpecial:WhatLinksHereDenmarkSolarIndustryDSI" Special pages About us Disclaimers Energy blogs Developer services OpenEI...

6

Common Rail Injection System Development  

DOE Green Energy (OSTI)

The collaborative research program between the Department of energy and Electro-Motive Diesels, Inc. on the development of common rail fuel injection system for locomotive diesel engines that can meet US EPA Tier 2 exhaust emissions has been completed. This final report summarizes the objectives of the program, work scope, key accomplishments and research findings. The major objectives of this project encompassed identification of appropriate injection strategies by using advanced analytical tools, development of required prototype hardware/controls, investigations of fuel spray characteristics including cavitation phenomena, and validation of hareware using a single-cylinder research locomotive diesel engine. Major milestones included: (1) a detailed modeling study using advanced mathematical models - several various injection profiles that show simultaneous reduction of NOx and particulates on a four stroke-cycle locomotive diesel engine were identified; (2) development of new common rail fuel injection hardware capable of providing these injection profiles while meeting EMD engine and injection performance specifications. This hardware was developed together with EMD's current fuel injection component supplier. (3) Analysis of fuel spray characteristics. Fuel spray numerical studies and high speed photographic imaging analyses were performed. (4) Validation of new hardware and fuel injection profiles. EMD's single-cylinder research diesel engine located at Argonne National Laboratory was used to confirm emissions and performacne predictions. These analytical ane experimental investigations resulted in optimized fuel injection profiles and engine operating conditions that yield reductions in NOx emissions from 7.8 g/bhp-hr to 5.0 g/bhp-hr at full (rated) load. Additionally, hydrocarbon and particulate emissions were reduced considerably when compared to baseline Tier I levels. The most significant finding from the injection optimization process was a 2% to 3% improvement in fuel economy over EMD's traditional Tier I engine hardware configuration. the common rail fuel injection system enabled this added benefit by virtue of an inherent capability to provide multiple injections per power stroke at high fuel rail pressures. On the basis of the findings in this study, EMD concludes that the new electronically-controlled high-pressure common rail injection system has the potential to meet locomotive Tier 2 NOx and particulates emission standards without sacrificing the fuel economy. A number of areas to further improve the injection hardware and engine operating characteristics to further exploit the benefits of common rail injection system have also been identified.

Electro-Motive,

2005-12-30T23:59:59.000Z

7

Particle beam injection system  

SciTech Connect

This invention provides a poloidal divertor for stacking counterstreaming ion beams to provide high intensity colliding beams. To this end, method and apparatus are provided that inject high energy, high velocity, ordered, atomic deuterium and tritium beams into a lower energy, toroidal, thermal equilibrium, neutral, target plasma column that is magnetically confined along an endless magnetic axis in a strong restoring force magnetic field having helical field lines to produce counterstreaming deuteron and triton beams that are received bent, stacked and transported along the endless axis, while a poloidal divertor removes thermal ions and electrons all along the axis to increase the density of the counterstreaming ion beams and the reaction products resulting therefrom. By balancing the stacking and removal, colliding, strong focused particle beams, reaction products and reactions are produced that convert one form of energy into another form of energy.

Jassby, Daniel L. (Princeton, NJ); Kulsrud, Russell M. (Princeton, NJ)

1977-01-01T23:59:59.000Z

8

Dry sorbent injection may serve as a key pollution control ...  

U.S. Energy Information Administration (EIA)

Dry sorbent injection (DSI) is a pollution control technology that may play a role in the United States' electric power sector's compliance with the Mercury and Air ...

9

Miniaturized flow injection analysis system  

DOE Patents (OSTI)

A chemical analysis technique known as flow injection analysis, wherein small quantities of chemical reagents and sample are intermixed and reacted within a capillary flow system and the reaction products are detected optically, electrochemically, or by other means. A highly miniaturized version of a flow injection analysis system has been fabricated utilizing microfabrication techniques common to the microelectronics industry. The microflow system uses flow capillaries formed by etching microchannels in a silicon or glass wafer followed by bonding to another wafer, commercially available microvalves bonded directly to the microflow channels, and an optical absorption detector cell formed near the capillary outlet, with light being both delivered and collected with fiber optics. The microflow system is designed mainly for analysis of liquids and currently measures 38.times.25.times.3 mm, but can be designed for gas analysis and be substantially smaller in construction.

Folta, James A. (Livermore, CA)

1997-01-01T23:59:59.000Z

10

Miniaturized flow injection analysis system  

DOE Patents (OSTI)

A chemical analysis technique known as flow injection analysis is described, wherein small quantities of chemical reagents and sample are intermixed and reacted within a capillary flow system and the reaction products are detected optically, electrochemically, or by other means. A highly miniaturized version of a flow injection analysis system has been fabricated utilizing microfabrication techniques common to the microelectronics industry. The microflow system uses flow capillaries formed by etching microchannels in a silicon or glass wafer followed by bonding to another wafer, commercially available microvalves bonded directly to the microflow channels, and an optical absorption detector cell formed near the capillary outlet, with light being both delivered and collected with fiber optics. The microflow system is designed mainly for analysis of liquids and currently measures 38{times}25{times}3 mm, but can be designed for gas analysis and be substantially smaller in construction. 9 figs.

Folta, J.A.

1997-07-01T23:59:59.000Z

11

Blast Furnace Granulated Coal Injection System Demonstration...  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Blast Furnace Granulated Coal Injection System Demonstration Project: A DOE Assessment June 2000 U. S. Department of Energy National Energy Technology Laboratory P.O. Box 880,...

12

Type-checking injective pure type systems  

Science Conference Proceedings (OSTI)

Injective pure type systems form a large class of pure type systems for which one can compute by purely syntactic means two sorts elmt(?∣M) and sort(?∣M), where ? is a pseudo-context and M is a pseudo-term, ...

Gilles Barthe

1999-11-01T23:59:59.000Z

13

Microfabricated injectable drug delivery system  

DOE Patents (OSTI)

A microfabricated, fully integrated drug delivery system capable of secreting controlled dosages of multiple drugs over long periods of time (up to a year). The device includes a long and narrow shaped implant with a sharp leading edge for implantation under the skin of a human in a manner analogous to a sliver. The implant includes: 1) one or more micromachined, integrated, zero power, high and constant pressure generating osmotic engine; 2) low power addressable one-shot shape memory polymer (SMP) valves for switching on the osmotic engine, and for opening drug outlet ports; 3) microfabricated polymer pistons for isolating the pressure source from drug-filled microchannels; 4) multiple drug/multiple dosage capacity, and 5) anisotropically-etched, atomically-sharp silicon leading edge for penetrating the skin during implantation. The device includes an externally mounted controller for controlling on-board electronics which activates the SMP microvalves, etc. of the implant.

Krulevitch, Peter A. (Pleasanton, CA); Wang, Amy W. (Oakland, CA)

2002-01-01T23:59:59.000Z

14

Capsule injection system for a hydraulic capsule pipelining system  

DOE Patents (OSTI)

An injection system for injecting capsules into a hydraulic capsule pipelining system, the pipelining system comprising a pipeline adapted for flow of a carrier liquid therethrough, and capsules adapted to be transported through the pipeline by the carrier liquid flowing through the pipeline. The injection system comprises a reservoir of carrier liquid, the pipeline extending within the reservoir and extending downstream out of the reservoir, and a magazine in the reservoir for holding capsules in a series, one above another, for injection into the pipeline in the reservoir. The magazine has a lower end in communication with the pipeline in the reservoir for delivery of capsules from the magazine into the pipeline.

Liu, Henry (Columbia, MO)

1982-01-01T23:59:59.000Z

15

Passive safety injection system using borated water  

DOE Patents (OSTI)

A passive safety injection system relies on differences in water density to induce natural circulatory flow patterns which help maintain prescribed concentrations of boric acid in borated water, and prevents boron from accumulating in the reactor vessel and possibly preventing heat transfer.

Conway, Lawrence E. (Allegheny, PA); Schulz, Terry L. (Westmoreland, PA)

1993-01-01T23:59:59.000Z

16

Dry Sorbent Injection Workshop Summary: Workshop Held November 11, 2011  

Science Conference Proceedings (OSTI)

A day-long dry sorbent injection (DSI) workshop was held in Charlotte, North Carolina, on November 20, 2011. The workshop was attended by representatives of over 20 electric power companies. Introductory remarks were made by Electric Power Research Institute (EPRI) staff, followed by presentations by 10 electric power companies describing their efforts and results from testing DSI technology for control of acid gases from flue gas. These testing efforts considered sulfur trioxide (SO3)/sulfuric acid, hyd...

2012-04-20T23:59:59.000Z

17

UP-GRADED RHIC INJECTION SYSTEM.  

Science Conference Proceedings (OSTI)

The design of the RHIC injection systems anticipated the possibility of filling and operating the rings with a 120 bunch pattern, corresponding to 110 bunches after allowing for the abort gap. Beam measurements during the 2002 run confirmed the possibility, although at the expense of severe transverse emittance growth and thus not on an operational basis. An improvement program was initiated with the goal of reducing the kicker rise time from 110 to {approx}95 ns and of minimizing pulse timing jitter and drift. The major components of the injection system are 4 kicker magnets and Blmlein pulsers using thyratron switches. The kicker terminating resistor and operating voltage was increased to reduce the rise time. Timing has been stabilized by using commercial trigger units and extremely stable dc supplies for the thyratron reservoir. A fiber optical connection between control room and the thyratron trigger unit has been provided, thereby allowing the operator to adjust timing individually for each kicker unit. The changes were successfully implemented for use in the RHIC operation.

HAHN,H.FISCHER,W.SEMERTZIDIS,Y.K.WARBURTON,D.S.

2003-05-12T23:59:59.000Z

18

D/sub 2/ - pellet injection system  

Science Conference Proceedings (OSTI)

For density build-up of a target plasma for neutral injection in the stellarator ''Wendelstein W VIIA''and for refuelling of the divertor tokamak ASSDEX, pellet light gas guns have been developed. In a continuous flow cryostat cooled by liquid helium with a comsumption of 2 - 3 liter liquid helium per hour deuterium was condensed and solidified. To prevent the propeller gas entering the torus was used. In one system a 3.6 mm guiding tube following the barrel was applied successfully. By optical diagnostics pellet velocity, pellet size and pellet trajectory is measured. For a pellet centrifuge system investigations of carbon fiber rotors were made up to surface velocities of 1500 m/s.

Buechl, K.; Andelfinger, C.; Kollotzek, H.; Lang, R.; Ulrich, M.

1981-01-01T23:59:59.000Z

19

Analytical steam injection model for layered systems  

SciTech Connect

Screening, evaluation and optimization of the steam flooding process in homogeneous reservoirs can be performed by using simple analytical predictive models. In the absence of any analytical model for layered reservoirs, at present, only numerical simulators can be used. And these are expensive. In this study, an analytical model has been developed considering two isolated layers of differing permeabilities. The principle of equal flow potential is applied across the two layers. Gajdica`s (1990) single layer linear steam drive model is extended for the layered system. The formulation accounts for variation of heat loss area in the higher permeability layer, and the development of a hot liquid zone in the lower permeability layer. These calculations also account for effects of viscosity, density, fractional flow curves and pressure drops in the hot liquid zone. Steam injection rate variations in the layers are represented by time weighted average rates. For steam zone calculations, Yortsos and Gavalas`s (1981) upper bound method is used with a correction factor. The results of the model are compared with a numerical simulator. Comparable oil and water flow rates, and breakthrough times were achieved for 100 cp oil. Results with 10 cp and 1000 cp oils indicate the need to improve the formulation to properly handle differing oil viscosities.

Abdual-Razzaq; Brigham, W.E.; Castanier, L.M.

1993-08-01T23:59:59.000Z

20

Mixed Mode Fuel Injector And Injection System  

DOE Patents (OSTI)

A fuel injector includes a homogenous charge nozzle outlet set and a conventional nozzle outlet set that are controlled respectively by first and second three way needle control valves. Each fuel injector includes first and second concentric needle valve members. One of the needle valve members moves to an open position for a homogenous charge injection event, while the other needle valve member moves to an open position for a conventional injection event. The fuel injector has the ability to operate in a homogenous charge mode with a homogenous charge spray pattern, a conventional mode with a conventional spray pattern or a mixed mode.

Stewart, Chris Lee (Normal, IL); Tian, Ye (Bloomington, IL); Wang, Lifeng (Normal, IL); Shafer, Scott F. (Morton, IL)

2005-12-27T23:59:59.000Z

Note: This page contains sample records for the topic "injection dsi systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

INJECTION SYSTEM DESIGN FOR THE BSNS/RCS.  

SciTech Connect

The BSNS injection system is designed to take one uninterrupted long drift in one of the four dispersion-free straight sections to host all the injection devices. Painting bumper magnets are used for both horizontal and vertical phase space painting. Closed-orbit bumper magnets are used for facilitating the installation of the injection septa and decreasing proton traversal in the stripping foil. Even with large beam emittance of about 300 {pi}mm.mrad used, BSNS/RCS still approaches the space charge limit during the injection/trapping phase for the accumulated particles of 1.9*10{sup 13} and at the low injection energy of 80 MeV. Uniform-like beam distribution by well-designed painting scheme is then obtained to decrease the tune shift/spread. ORBIT code is used for the 3D simulations. Upgrading to higher injection energy has also been considered.

WEI, J.; TANG, J.Y.; CHEN, Y.; CHI, Y.L.; JIANG, Y.L.; KANG, W.; PANG, J.B.; QIN, Q.; QIU, J.; SHEN, L.; WANG, W.

2006-06-23T23:59:59.000Z

22

Nox reduction system utilizing pulsed hydrocarbon injection  

DOE Patents (OSTI)

Hydrocarbon co-reductants, such as diesel fuel, are added by pulsed injection to internal combustion engine exhaust to reduce exhaust NO.sub.x to N.sub.2 in the presence of a catalyst. Exhaust NO.sub.x reduction of at least 50% in the emissions is achieved with the addition of less than 5% fuel as a source of the hydrocarbon co-reductants. By means of pulsing the hydrocarbon flow, the amount of pulsed hydrocarbon vapor (itself a pollutant) can be minimized relative to the amount of NO.sub.x species removed.

Brusasco, Raymond M. (Livermore, CA); Penetrante, Bernardino M. (San Ramon, CA); Vogtlin, George E. (Fremont, CA); Merritt, Bernard T. (Livermore, CA)

2001-01-01T23:59:59.000Z

23

Controlled air injection for a fuel cell system  

DOE Patents (OSTI)

A method and apparatus for injecting oxygen into a fuel cell reformate stream to reduce the level of carbon monoxide while preserving the level of hydrogen in a fuel cell system.

Fronk, Matthew H. (Honeove Falls, NY)

2002-01-01T23:59:59.000Z

24

Injection locked oscillator system for pulsed metal vapor lasers  

SciTech Connect

An injection locked oscillator system for pulsed metal vapor lasers is disclosed. The invention includes the combination of a seeding oscillator with an injection locked oscillator (ILO) for improving the quality, particularly the intensity, of an output laser beam pulse. The present invention includes means for matching the first seeder laser pulses from the seeding oscillator to second laser pulses of a metal vapor laser to improve the quality, and particularly the intensity, of the output laser beam pulse.

Warner, Bruce E. (Livermore, CA); Ault, Earl R. (Dublin, CA)

1988-01-01T23:59:59.000Z

25

Water injected fuel cell system compressor  

DOE Patents (OSTI)

A fuel cell system including a dry compressor for pressurizing air supplied to the cathode side of the fuel cell. An injector sprays a controlled amount of water on to the compressor's rotor(s) to improve the energy efficiency of the compressor. The amount of water sprayed out the rotor(s) is controlled relative to the mass flow rate of air inputted to the compressor.

Siepierski, James S. (Williamsville, NY); Moore, Barbara S. (Victor, NY); Hoch, Martin Monroe (Webster, NY)

2001-01-01T23:59:59.000Z

26

A fast injection kicker system for the Tevatron  

Science Conference Proceedings (OSTI)

A new proton injection kicker system is required for the Tevatron in the Run II era. The new system was designed to supply 1.25 kG-m into a magnetic aperture of 48 mm vertical x 71 mm horizontal x 5 m long with a 396 ns bunch spacing. The system was designed to be upgraded to 132 ns bunch spacing with additional pulse supplies. The system design tradeoffs needed to meet these goals is discussed. These include the system topology, the system impedance and the number of magnets. This system has been installed in the Tevatron.

Chris C. Jensen, Robert E. Reilly and Bruce M. Hanna

2001-07-25T23:59:59.000Z

27

Ultra Bright LED Light Injection Calibration System for MINOS  

E-Print Network (OSTI)

We describe here a proposal for a light injection calibration system for the MINOS detectors based on ultra bright blue LEDs as the light source. We have shown that these LEDs are bright enough to span over two orders of magnitude in light intensity, commensurate with that expected in a single scintillator strip in the MINOS neutrino detectors.

Anderson, B; Dervan, P J; Lauber, J A; Thomas, J

1999-01-01T23:59:59.000Z

28

Flow monitoring and control system for injection wells  

DOE Patents (OSTI)

The present invention relates to a system for monitoring and controlling the rate of fluid flow from an injection well used for in-situ remediation of contaminated groundwater. The United States Government has rights in this invention pursuant to Contract No. DE-AC09-89SR18035 between the US Department of Energy and Westinghouse Savannah River Company.

Corey, J.C.

1991-01-01T23:59:59.000Z

29

Ultra Bright LED Light Injection Calibration System for MINOS  

E-Print Network (OSTI)

We describe here a proposal for a light injection calibration system for the MINOS detectors based on ultra bright blue LEDs as the light source. We have shown that these LEDs are bright enough to span over two orders of magnitude in light intensity, commensurate with that expected in a single scintillator strip in the MINOS neutrino detectors.

B. Anderson; A. Anjomshoaa; P. Dervan; J. A. Lauber; J. Thomas

1998-10-26T23:59:59.000Z

30

Ultra Bright LED Light Injection Calibration System for MINOS  

E-Print Network (OSTI)

We describe here a proposal for a light injection calibration system for the MINOS detectors based on ultra bright blue LEDs as the light source. We have shown that these LEDs are bright enough to span over two orders of magnitude in light intensity, commensurate with that expected in a single scintillator strip in the MINOS neutrino detectors. 1

B. Anderson; A. Anjomshoaa; P. Dervan; J. A. Lauber; J. Thomas

2008-01-01T23:59:59.000Z

31

Flow monitoring and control system for injection wells  

DOE Patents (OSTI)

A system for monitoring and controlling the injection rate of fluid by an injection well of an in-situ remediation system for treating a contaminated groundwater plume. The well is fitted with a gated insert, substantially coaxial with the injection well. A plurality of openings, some or all of which are equipped with fluid flow sensors and gates, are spaced along the insert. The gates and sensors are connected to a surface controller. The insert may extend throughout part of, or substantially the entire length of the injection well. Alternatively, the insert may comprise one or more movable modules which can be positioned wherever desired along the well. The gates are opened part-way at the start of treatment. The sensors monitor and display the flow rate of fluid passing through each opening on a controller. As treatment continues, the gates are opened to increase flow in regions of lesser flow, and closed to decrease flow in regions of greater flow, thereby approximately equalizing the amount of fluid reaching each part of the plume.

Corey, John C. (212 Lakeside Dr., Aiken, SC 29803)

1993-01-01T23:59:59.000Z

32

Flow monitoring and control system for injection wells  

DOE Patents (OSTI)

A system for monitoring and controlling the injection rate of fluid by an injection well of an in-situ remediation system for treating a contaminated groundwater plume. The well is fitted with a gated insert, substantially coaxial with the injection well. A plurality of openings, some or all of which are equipped with fluid flow sensors and gates, are spaced along the insert. The gates and sensors are connected to a surface controller. The insert may extend throughout part of, or substantially the entire length of the injection well. Alternatively, the insert may comprise one or more movable modules which can be positioned wherever desired along the well. The gates are opened part-way at the start of treatment. The sensors monitor and display the flow rate of fluid passing through each opening on a controller. As treatment continues, the gates are opened to increase flow in regions of lesser flow, and closed to decrease flow in regions of greater flow, thereby approximately equalizing the amount of fluid reaching each part of the plume.

Corey, J.C.

1993-02-16T23:59:59.000Z

33

Jet plume injection and combustion system for internal combustion engines  

DOE Patents (OSTI)

An improved combustion system for an internal combustion engine is disclosed wherein a rich air/fuel mixture is furnished at high pressure to one or more jet plume generator cavities adjacent to a cylinder and then injected through one or more orifices from the cavities into the head space of the cylinder to form one or more turbulent jet plumes in the head space of the cylinder prior to ignition of the rich air/fuel mixture in the cavity of the jet plume generator. The portion of the rich air/fuel mixture remaining in the cavity of the generator is then ignited to provide a secondary jet, comprising incomplete combustion products which are injected into the cylinder to initiate combustion in the already formed turbulent jet plume. Formation of the turbulent jet plume in the head space of the cylinder prior to ignition has been found to yield a higher maximum combustion pressure in the cylinder, as well as shortening the time period to attain such a maximum pressure.

Oppenheim, Antoni K. (Kensington, CA); Maxson, James A. (Berkeley, CA); Hensinger, David M. (Albany, CA)

1993-01-01T23:59:59.000Z

34

Jet plume injection and combustion system for internal combustion engines  

DOE Patents (OSTI)

This invention is comprised of an improved combustion system for an internal combustion engine is disclosed wherein a rich air/fuel mixture is furnished at high pressure to one or more jet plume generator cavities adjacent to a cylinder and then injected through one or more orifices from the cavities into the head space of the cylinder to form one or more turbulent jet plumes in the head space of the cylinder prior to ignition of the rich air/fuel mixture in the cavity of the jet plume generator. The portion of the rich air/fuel mixture remaining in the cavity of the generator is then ignited to provide a secondary jet, comprising incomplete combustion products which are injected into the cylinder to initiate combustion in the already formed turbulent jet plume. Formation of the turbulent jet plume in the head space of the cylinder prior to ignition has been found to yield a higher maximum combustion pressure in the cylinder, as well as shortening the time period to attain such a maximum pressure.

Oppenheim, A.K.; Maxson, J.A.; Hensinger, D.M.

1992-12-31T23:59:59.000Z

35

Jet plume injection and combustion system for internal combustion engines  

DOE Patents (OSTI)

An improved combustion system for an internal combustion engine is disclosed wherein a rich air/fuel mixture is furnished at high pressure to one or more jet plume generator cavities adjacent to a cylinder and then injected through one or more orifices from the cavities into the head space of the cylinder to form one or more turbulent jet plumes in the head space of the cylinder prior to ignition of the rich air/fuel mixture in the cavity of the jet plume generator. The portion of the rich air/fuel mixture remaining in the cavity of the generator is then ignited to provide a secondary jet, comprising incomplete combustion products which are injected into the cylinder to initiate combustion in the already formed turbulent jet plume. Formation of the turbulent jet plume in the head space of the cylinder prior to ignition has been found to yield a higher maximum combustion pressure in the cylinder, as well as shortening the time period to attain such a maximum pressure. 24 figures.

Oppenheim, A.K.; Maxson, J.A.; Hensinger, D.M.

1993-12-21T23:59:59.000Z

36

Study on Zero CO2 Emission SOFC Hybrid Power System with Steam Injection  

Science Conference Proceedings (OSTI)

Based on a traditional SOFC hybrid power system, a zero CO2 emission SOFC hybrid power system with steam injection is proposed in this paper and its performance is analyzed. Oxy-fuel combustion can burn the fuel gas from anode thoroughly, and increases ... Keywords: solid oxide fuel cell, Aspen Plus, hybrid power system, zero CO2 emission, steam injection

Liqiang Duan; Xiaoyuan Zhang; Yongping Yang; Gang Xu

2010-06-01T23:59:59.000Z

37

Dry low NOx combustion system with pre-mixed direct-injection secondary fuel nozzle  

Science Conference Proceedings (OSTI)

A combustion system includes a first combustion chamber and a second combustion chamber. The second combustion chamber is positioned downstream of the first combustion chamber. The combustion system also includes a pre-mixed, direct-injection secondary fuel nozzle. The pre-mixed, direct-injection secondary fuel nozzle extends through the first combustion chamber into the second combustion chamber.

Zuo, Baifang; Johnson, Thomas; Ziminsky, Willy; Khan, Abdul

2013-12-17T23:59:59.000Z

38

FERRARI: A Flexible Software-Based Fault and Error Injection System  

Science Conference Proceedings (OSTI)

Abstract¿A major step toward the development offault-tolerant computer systems is the validation of the dependability properties of these systems. Fault/error injection has been recognized as a powerful approach to validate the fault tolerance mechanisms ...

Ghani A. Kanawati; Nasser A. Kanawati; Jacob A. Abraham

1995-02-01T23:59:59.000Z

39

Supplement to Administrator's Record of Decision on Bonneville Power Administration's Service to Direct Service Industrial (DSI) Customers for Fiscal Years 2007-2011 (DOE/EIS-0183) (05/31/06)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

SUPPLEMENT TO ADMINISTRATOR'S RECORD OF DECISION ON SUPPLEMENT TO ADMINISTRATOR'S RECORD OF DECISION ON BONNEVILLE POWER ADMINISTRATION'S SERVICE TO DIRECT SERVICE INDUSTRIAL (DSI) CUSTOMERS FOR FISCAL YEARS 2007-2011 ADMINISTRATOR'S RECORD OF DECISION Bonneville Power Administration U.S. Department of Energy May 31, 2006 1 Supplement to Administrator's Record of Decision on Bonneville Power Administration's Service to Direct Service Industrial (DSI) Customers for Fiscal Years 2007-2011 I. Background On February 4, 2005, Bonneville Power Administration (BPA) sent a letter to customers and constituents describing a public process for comments on certain issues related to service by BPA to its remaining direct service industrial (DSI) customers that had not been finally decided in the Policy For Power Supply Role For Fiscal Years 2007-

40

Coanda injection system for axially staged low emission combustors  

SciTech Connect

The low emission combustor includes a combustor housing defining a combustion chamber having a plurality of combustion zones. A liner sleeve is disposed in the combustion housing with a gap formed between the liner sleeve and the combustor housing. A secondary nozzle is disposed along a centerline of the combustion chamber and configured to inject a first fluid comprising air, at least one diluent, fuel, or combinations thereof to a downstream side of a first combustion zone among the plurality of combustion zones. A plurality of primary fuel nozzles is disposed proximate to an upstream side of the combustion chamber and located around the secondary nozzle and configured to inject a second fluid comprising air and fuel to an upstream side of the first combustion zone. The combustor also includes a plurality of tertiary coanda nozzles. Each tertiary coanda nozzle is coupled to a respective dilution hole. The tertiary coanda nozzles are configured to inject a third fluid comprising air, at least one other diluent, fuel, or combinations thereof to one or more remaining combustion zones among the plurality of combustion zones.

Evulet, Andrei Tristan (Clifton Park, NY); Varatharajan, Balachandar (Cincinnati, OH); Kraemer, Gilbert Otto (Greer, SC); ElKady, Ahmed Mostafa (Niskayuna, NY); Lacy, Benjamin Paul (Greer, SC)

2012-05-15T23:59:59.000Z

Note: This page contains sample records for the topic "injection dsi systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Manufacturing injection-moleded Fresnel lens parquets for point-focus concentrating photovoltaic systems  

DOE Green Energy (OSTI)

This project involved the manufacturing of curved-faceted, injection-molded, four-element Fresnel lens parquets for concentrating photovoltaic arrays. Previous efforts showed that high-efficiency (greater than 82%) Fresnel concentrators could be injection molded. This report encompasses the mold design, molding, and physical testing of a four-lens parquet for a solar photovoltaic concentrator system.

Peters, E.M.; Masso, J.D. [AOtec, Southbridge, MA (United States)

1995-10-01T23:59:59.000Z

42

Neural Predictive Controller Based Diesel Injection Management System for Emission Minimisation  

Science Conference Proceedings (OSTI)

Rapid growth in production of automobiles has increased emissions. Automotive control engineers use innovative control techniques to meet the upcoming emission standards. This paper proposes a novel method of employing artificial neural network ANN based ... Keywords: Artificial Neural Network ANN, Common Rail System CRS, Control System Simulation, Emission Minimisation, Fuel Injection System, Green System Design, Green Technology

C. N. Arunaa; S. Babu Devasenapati; K. I. Ramachandran; K. Vishnuprasad; C. Surendra

2011-07-01T23:59:59.000Z

43

Micronized-coal-water slurry sprays from a diesel engine positive displacement fuel injection system  

DOE Green Energy (OSTI)

Experiments have been conducted to characterize the sprays from a modified positive displacement fuel injection system for a diesel engine. Diesel fuel water and three concentrations of micronized-coal-water slurry were used in these experiments. The injection system includes an injection jerk pump driven by an electric motor, a specially designed diaphragm to separate the abrasive coal slurry fuel from the pump, and a single-hole fuel nozzle. The sprays were injected into a pressurized chamber equipped with windows. High speed movies and still photographs of the sprays were obtained. In addition, instaneous fuel line pressures and needle lifts were obtained. Data were acquired as a function of fluid, nozzle orifice diameter, rack setting and chamber conditions. The high speed movies were used to determine spray penetration and spray growth.

Caton, J.A.; Kihm, K.D.; Seshadri, A.K.; Zicterman, G. [Texas A and M Univ., College Station, TX (United States). Dept. of Mechanical Engineering

1991-12-31T23:59:59.000Z

44

Fuel injection and mixing systems having piezoelectric elements and methods of using the same  

Science Conference Proceedings (OSTI)

A fuel injection and mixing system is provided that is suitable for use with various types of fuel reformers. Preferably, the system includes a piezoelectric injector for delivering atomized fuel, a gas swirler, such as a steam swirler and/or an air swirler, a mixing chamber and a flow mixing device. The system utilizes ultrasonic vibrations to achieve fuel atomization. The fuel injection and mixing system can be used with a variety of fuel reformers and fuel cells, such as SOFC fuel cells.

Mao, Chien-Pei (Clive, IA); Short, John (Norwalk, IA); Klemm, Jim (Des Moines, IA); Abbott, Royce (Des Moines, IA); Overman, Nick (West Des Moines, IA); Pack, Spencer (Urbandale, IA); Winebrenner, Audra (Des Moines, IA)

2011-12-13T23:59:59.000Z

45

An Innovative Injection and Mixing System for Diesel Fuel Reforming  

DOE Green Energy (OSTI)

This project focused on fuel stream preparation improvements prior to injection into a solid oxide fuel cell reformer. Each milestone and the results from each milestone are discussed in detail in this report. The first two milestones were the creation of a coking formation test rig and various testing performed on this rig. Initial tests indicated that three anti-carbon coatings showed improvement over an uncoated (bare metal) baseline. However, in follow-up 70 hour tests of the down selected coatings, Scanning Electron Microscope (SEM) analysis revealed that no carbon was generated on the test specimens. These follow-up tests were intended to enable a down selection to a single best anti-carbon coating. Without the formation of carbon it was impossible to draw conclusions as to which anti-carbon coating showed the best performance. The final 70 hour tests did show that AMCX AMC26 demonstrated the lowest discoloration of the metal out of the three down selected anti-carbon coatings. This discoloration did not relate to carbon but could be a useful result when carbon growth rate is not the only concern. Unplanned variations in the series of tests must be considered and may have altered the results. Reliable conclusions could only be drawn from consistent, repeatable testing beyond the allotted time and funding for this project. Milestones 3 and 4 focused on the creation of a preheating pressure atomizer and mixing chamber. A design of experiment test helped identify a configuration of the preheating injector, Build 1, which showed a very uniform fuel spray flow field. This injector was improved upon by the creation of a Build 2 injector. Build 2 of the preheating injector demonstrated promising SMD results with only 22psi fuel pressure and 0.7 in H2O of Air. It was apparent from testing and CFD that this Build 2 has flow field recirculation zones. These recirculation zones may suggest that this Build 2 atomizer and mixer would require steam injection to reduce the auto ignition potential. It is also important to note that to achieve uniform mixing within a short distance, some recirculation is necessary. Milestone 5 generated CFD and FEA results that could be used to optimize the preheating injector. CFD results confirmed the recirculation zones seen in test data and confirmed that the flow field would not change when attached to a reformer. The FEA predicted fuel wetted wall temperatures which led to several suggested improvements that could possibly improve nozzle efficiency. Milestone 6 (originally an optional task) took a different approach than the preheating pressure atomizer. It focused on creation and optimization of a piezoelectric injector which could perform at extremely low fuel pressures. The piezoelectric atomizer showed acceptable SMD results with fuel pressure less than 1.0 psig and air pressure less than 1.0 in H2O. These SMD values were enhanced when a few components were changed, and it is expected would improve further still at elevated air temperatures. It was demonstrated that the piezoelectric injector could accomplish the desired task. The addition of phase tracking and a burst mode to the frequency controller increased the usability of the piezoelectric injector. This injector is ready to move on to the next phase of development. Engine Components has met the required program milestones of this project. Some of the Milestones were adjusted to allow Milestone 6 to be completed in parallel with the other Milestones. Because of this, Task 3.10 and 3.13 were made optional instead of Milestone 6. Engine Components was extremely grateful for the support that was provided by NETL in support of this work.

Spencer Pack

2007-12-31T23:59:59.000Z

46

Geology of Injection Well 46A-19RD in the Coso Enhanced Geothermal Systems  

Open Energy Info (EERE)

of Injection Well 46A-19RD in the Coso Enhanced Geothermal Systems of Injection Well 46A-19RD in the Coso Enhanced Geothermal Systems Experiment Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Conference Proceedings: Geology of Injection Well 46A-19RD in the Coso Enhanced Geothermal Systems Experiment Details Activities (1) Areas (1) Regions (0) Abstract: The Coso Geothermal Field is a large, high temperature system located in California on the western edge of the Basin and Range province. Well 46A-19RD, located in the southwestern portion of this field is currently the focus of a DOE-funded Enhanced Geothermal Systems (EGS) project. Petrologic and petrographic investigations of the well show that quartz diorite and granodiorite are dominant lithologies. Dikes of granophyre, containing phenocrysts of plagioclase, potassium feldspar, and

47

Materials for High-Pressure Fuel Injection Systems  

DOE Green Energy (OSTI)

The high-level goal of this multi-year effort was to facilitate the Advanced Combustion Engine goal of 20% improvement (compared to 2009 baseline) of commercial engine efficiency by 2015. A sub-goal is to increase the reliability of diesel fuel injectors by investigating modelbased scenarios that cannot be achieved by empirical, trial and error methodologies alone. During this three-year project, ORNL developed the methodology to evaluate origins and to record the initiation and propagation of fatigue cracks emanating from holes that were electrodischarge machined (EDM), the method used to form spray holes in fuel injector tips. Both x-ray and neutron-based methods for measuring residual stress at four different research facilities were evaluated to determine which, if any, was most applicable to the fuel injector tip geometry. Owing to the shape and small volumes of material involved in the sack area, residual stress data could only be obtained in the walls of the nozzle a few millimeters back from the tip, and there was a hint of only a small compressive stress. This result was consistent with prior studies by Caterpillar. Residual stress studies were suspended after the second year, reserving the possibility of pursuing this in the future, if and when methodology suitable for injector sacks becomes available. The smooth specimen fatigue behavior of current fuel injector steel materials was evaluated and displayed a dual mode initiation behavior. At high stresses, cracks started at machining flaws in the surface; however, below a critical threshold stress of approximately 800 MPa, cracks initiated in the bulk microstructure, below the surface. This suggests that for the next generation for high-pressure fuel injector nozzles, it becomes increasingly important to control the machining and finishing processes, especially if the stress in the tip approaches or exceeds that threshold level. Fatigue tests were also conducted using EDM notches in the gage sections. Compared to the smooth specimens, EDM notching led to a severe reduction in total fatigue life. A reduction in fatigue life of nearly four orders of magnitude can occur at an EDM notch the approximate size of fuel injector spray holes. Consequently, the initiation and propagation behavior of cracks from small spray holes is relevant for generation of design quality data for the next generation diesel fuel injection devices. This is especially true since the current design methodologies usually rely on the less conservative smooth specimen fatigue testing results, and since different materials can have varying levels of notch fatigue resistance.

Blau, P.; Shyam, A.; Hubbard, C.; Howe, J.; Trejo, R.; Yang, N. (Caterpillar, Inc. Technical Center); Pollard, M. (Caterpillar, Inc. Technical Center)

2011-09-30T23:59:59.000Z

48

Computerized data acquisition system for production, injection and interference tests  

DOE Green Energy (OSTI)

A computer-based system for collecting, processing, and analyzing pressure transient data has been developed. Primary components include downhole pressure sensors, linedrivers, a micro-computer, data storage disk, scanner, frequency counter, digital voltmeter, power supply, graphics plotter, and printer. In-field data processing and analysis greatly aid in handling the large volume of data that are collected during pressure transients tests, particularly the multiwell interference tests that are so important for characterizing and assessing geothermal reservoirs. In-field data processing provides the field engineer, on a real-time basis, with the information needed to make decisions regarding test parameters and duration. The system has been used on numerous occasions and has proved itself to be reliable under the harsh operating conditions that are usually encountered in the field. This paper describes the advantages of using this type of system for collecting data, the components and configuration of the system, and the software programs used to collect and process the data. Finally, two field applications are presented.

Benson, S.M.

1986-06-01T23:59:59.000Z

49

Injection-seeded optical parametric oscillator and system  

DOE Patents (OSTI)

Optical parametric oscillators (OPO) and systems are provided. The OPO has a non-linear optical material located between two optical elements where the product of the reflection coefficients of the optical elements are higher at the output wavelength than at either the pump or idler wavelength. The OPO output may be amplified using an additional optical parametric amplifier (OPA) stage.

Lucht, Robert P. (West Lafayette, IN); Kulatilaka, Waruna D. (West Lafayette, IN); Anderson, Thomas N. (Seguin, TX); Bougher, Thomas L. (Dublin, OH)

2007-10-09T23:59:59.000Z

50

Modeling of geomechanical proceses during injection in amultilayered reservoir-caprock system and implications on sitecharacterization  

Science Conference Proceedings (OSTI)

In this paper we present results of a numerical simulationof the potential for fault reactivation and hydraulic fracturingassociated with CO2 injection in a multilayered reservoir-caprock system,and discuss its implications on site characterization. The numericalsimulation is performed using the coupled processes simulator TOUGH-FLAC(Rutqvist et al. 2002, Rutqvist and Tsang, 2003), and is an extension ofearlier numerical studies of a single caprock system (Rutqvist and Tsang,2002). In this study, CO2 is injected for 30 years in a 200 meter thickpermeable saline water formation located at 1600 meters depth (Figure 1).The injection formation is overlaid by several layers of caprocks, whichare intersected by a permeable fault zone allowing upward migration ofthe CO2 within the multilayered system (see Table 1 for materialproperties). The potential for fault slip or fracturing are calculated,based on the time-dependent evolution and local distribution of fluidpressure and the three-dimensional stress field, including importantporo-elastic stresses.The numerical results are discussed with respect tothe site-characterization strategy that would be recommended forevaluation of maximum sustainable injection pressure at an industrial CO2injection site.

Rutqvist, Jonny; Birkholzer, Jens; Tsang, Chin-Fu

2006-03-01T23:59:59.000Z

51

Coal-water slurry spray characteristics of a positive displacement fuel injection system  

DOE Green Energy (OSTI)

Experiments have been completed to characterized coal-water slurry sprays from a modified positive displacement fuel injection system of a diesel engine. The injection system includes an injection jerk pump driven by an electric motor, a specially designed diaphragm to separate the abrasive coal from the pump, and a single-hole fuel nozzle. The sprays were injected into a pressurized chamber equipped with windows. High speed movies and instantaneous fuel line pressures were obtained. For injection pressures of order 30 MPa or higher, the sprays were similar for coal-water slurry, diesel fuel and water. The time until the center core of the spray broke-up (break-up time) was determined from both the movies and from a model using the fuel line pressures. Results from these two independent procedures were in good agreement. For the base conditions, the break-up time was 0.58 and 0.50 ms for coal-water slurry and diesel fuel, respectively. The break-up times increased with increasing nozzle orifice size and with decreasing chamber density. The break-up time was not a function of coal loading for coal loadings up to 53%. Cone angles of the sprays were dependent on the operating conditions and fluid, as well as on the time and location of the measurement. For one set of cases studied, the time-averaged cone angle was 15.9{degree} and 16.3{degree} for coal-water slurry and diesel fuel, respectively.

Seshadri, A.K.; Caton, J.A.; Kihm, K.D. [Texas A and M Univ., College Station, TX (United States). Dept. of Mechanical Engineering

1992-12-31T23:59:59.000Z

52

Preliminary Failure Modes and Effects Analysis of the US Massive Gas Injection Disruption Mitigation System Design  

Science Conference Proceedings (OSTI)

This report presents the results of a preliminary failure modes and effects analysis (FMEA) of a candidate design for the ITER Disruption Mitigation System. This candidate is the Massive Gas Injection System that provides machine protection in a plasma disruption event. The FMEA was quantified with “generic” component failure rate data as well as some data calculated from operating facilities, and the failure events were ranked for their criticality to system operation.

Lee C. Cadwallader

2013-10-01T23:59:59.000Z

53

Supplement to Administrator's Record of Decision on Bonneville Power Administration's Service to Direct Service Industrial (DSI) Customers for Fiscal Years 2007-2011 (DOE/EIS-0183) (06/19/06)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

266 Federal Register 266 Federal Register / Vol. 71, No. 117 / Monday, June 19, 2006 / Notices Education, Room 5C141, 400 Maryland Avenue, SW., Washington, DC 20202. [FR Doc. 06-5528 Filed 6-16-06; 8:45 am] BILLING CODE 4000-01-M DEPARTMENT OF ENERGY Bonneville Power Administration Supplement to Administrator's Record of Decision on Bonneville Power Administration's Service to Direct Service Industrial (DSI) Customers for Fiscal Years 2007-2011 AGENCY: Bonneville Power Administration (BPA), Department of Energy. ACTION: Notice of final policy. SUMMARY: BPA Administrator Stephen J. Wright signed a supplement to the Administrator's Record of Decision (ROD) on Bonneville Power Administration's Service to Direct Service Industrial (DSI) Customers for Fiscal Years 2007-2011. The original

54

[Martin high pressure common rail diesel engine injection system]. Technical progress report, August--October 1995  

DOE Green Energy (OSTI)

We have a contract with Diesel Recerche of Trieste, Italy, and the Fincantier Group in Italy. They are naval ship builders. Our contract is to work with Diesel Recerche to design the `Martin` fuel injection system for their first test engine for a naval ship. Tiby Martin has been working in the design and detailed layout of the application drawings for Diesel Recerche.

NONE

1995-12-01T23:59:59.000Z

55

Modeling Single Well Injection-Withdrawal (SWIW) Tests for Characterization of Complex Fracture-Matrix Systems  

E-Print Network (OSTI)

not just near the injection well. Note that because thisConcentrations at the injection well increase during thethe fractures away from the injection well is fast, solutes

Cotte, F.P.

2012-01-01T23:59:59.000Z

56

Injection Timing Effects on Brake Fuel Conversion Efficiency and Engine System's Respones  

E-Print Network (OSTI)

Societal concerns on combustion-based fuel consumption are ever-increasing. With respect to internal combustion engines, this translates to a need to increase brake fuel conversion efficiency (BFCE). Diesel engines are a relatively efficient internal combustion engine to consider for numerous applications, but associated actions to mitigate certain exhaust emissions have generally deteriorated engine efficiency. Conventionally, diesel engine emission control has centered on in-cylinder techniques. Although these continue to hold promise, the industry trend is presently favoring the use of after-treatment devices which create new opportunities to improve the diesel engine's brake fuel conversion efficiency. This study focuses on injection timing effects on the combustion processes, engine efficiency, and the engine system's responses. The engine in the study is a medium duty diesel engine (capable of meeting US EPA Tier III off road emission standards) equipped with common rail direct fuel injection, variable geometry turbo charging, and interfaced with a custom built engine controller. The study found that injection timing greatly affected BFCE by changing the combustion phasing. BFCE would increase up to a maximum then begin to decrease as phasing became less favorable. Combustion phasing would change from being mostly mixing controlled combustion to premixed combustion as injection timing would advance allowing more time for fuel to mix during the ignition delay. Combustion phasing, in turn, would influence many other engine parameters. As injection timing is advanced, in-cylinder temperatures and pressures amplify, and intake and exhaust manifold pressures deteriorate. Rate of heat release and rate of heat transfer increase when injection timing is advanced. Turbocharger speed falls with the advancing injection timing. Torque, however, rose to a maximum then fell off again even though engine speed and fueling rate were held constant between different injection timings. Interestingly, the coefficient of heat transfer changes from a two peak curve to a smooth one peak curve as the injection timing is advanced further. The major conclusion of the study is that injection advance both positively and negatively influences the diesel engine's response which contributes to the brake fuel conversion efficiency.

McLean, James Elliott

2011-08-01T23:59:59.000Z

57

Refrigeration system with a compressor-pump unit and a liquid-injection desuperheating line  

DOE Patents (OSTI)

The refrigeration system includes a compressor-pump unit and/or a liquid-injection assembly. The refrigeration system is a vapor-compression refrigeration system that includes an expansion device, an evaporator, a compressor, a condenser, and a liquid pump between the condenser and the expansion device. The liquid pump improves efficiency of the refrigeration system by increasing the pressure of, thus subcooling, the liquid refrigerant delivered from the condenser to the expansion device. The liquid pump and the compressor are driven by a single driving device and, in this regard, are coupled to a single shaft of a driving device, such as a belt-drive, an engine, or an electric motor. While the driving device may be separately contained, in a preferred embodiment, the liquid pump, the compressor, and the driving device (i.e., an electric motor) are contained within a single sealable housing having pump and driving device cooling paths to subcool liquid refrigerant discharged from the liquid pump and to control the operating temperature of the driving device. In another aspect of the present invention, a liquid injection assembly is included in a refrigeration system to divert liquid refrigerant from the discharge of a liquid pressure amplification pump to a compressor discharge pathway within a compressor housing to desuperheat refrigerant vapor to the saturation point within the compressor housing. The liquid injection assembly includes a liquid injection pipe with a control valve to meter the volume of diverted liquid refrigerant. The liquid injection assembly may also include a feedback controller with a microprocessor responsive to a pressure sensor and a temperature sensor both positioned between the compressor to operate the control valve to maintain the refrigerant at or near saturation.

Gaul, Christopher J. (Thornton, CO)

2001-01-01T23:59:59.000Z

58

Numerical studies of cold water injection into vapor-dominated geothermal systems  

DOE Green Energy (OSTI)

Recent reservoir pressure and steam flow rate declines at The Geysers geothermal field in California have attracted interest in studies of increased cold water injection into this system. In this paper, numerical studies of such injection into a fractured vapor-dominated reservoir are conducted using a two-dimensional radial, double-porosity model. The results obtained indicate that cold water injection into superheated (low-pressure) zones will greatly enhance the productivities of steam wells. Injection into two-phase zones with significant liquid reserves in the matrix blocks does not appear to aid in steam recovery until most of the original liquid reserves are depleted. Sensitivity studies are conducted over the range of fracture and matrix permeabilities applicable to the Geysers. The sensitivity of the grid size is also conducted, and shows very large grid effects. A fine vertical space discretization near the bottom of the reservoir is necessary to accurately predict the boiling of the injected water. 28 refs., 15 figs., 3 tabs.

Lai, C.H; Bodvarsson, G.S.

1991-01-01T23:59:59.000Z

59

The Injection System of the INFN-SuperB Factory Project: Preliminary Design  

Science Conference Proceedings (OSTI)

The ultra high luminosity B-factory (SuperB) project of INFN requires a high performance and reliable injection system, providing electrons at 4 GeV and positrons at 7 GeV, to fulfil the very tight requirements of the collider. Due to the short beam lifetime, continuous injection of electron and positron bunches in both LER and HER rings is necessary to maintain an high average luminosity. Polarized electrons are required for experiments and must be delivered by the injection system, due to the beam lifetime shorter than the ring polarization build-up: they will be produced by means of a SLAC-SLC polarized gun. The emittance and the energy spread of the e{sup -}/e{sup +} beams are reduced in a 1 GeV Damping Ring (DR) before injection in the main rings. Two schemes for positron production are under study, one with e{sup -}/e{sup +} conversion at low energy (conversion at 6 GeV and a recirculation line to bring the positrons back to the DR. Acceleration through the Linac is provided by a 2856 MHz RF system made of travelling wave (TW), room temperature accelerating structures.

Boni, Roberto; /INFN, Rome; Guiducci, Susanna; /INFN, Rome; Preger, Miro; /INFN, Rome; Raimondi, Pantaleo; /INFN, Rome; Chance, Antoine; /Saclay; Dadoun, Olivier; /Orsay, LAL; Poirier, Freddy; /Orsay, LAL; Variola, Alessandro; /Orsay, LAL; Seeman, John; /SLAC

2012-07-05T23:59:59.000Z

60

Visualization and simulation of immiscible displacement in fractured systems using micromodels: Steam injection  

SciTech Connect

A study of steam and hot water injection processes in micromodel geometries that mimic a matrix-fracture system was undertaken. The followings were observed: Light components existing in the crude oil generated a very high efficient gas-drive at elevated temperatures. This gas generation in conjunction with natural surfactant existing in the crude oil, lead to the formation of a foam in the fracture and to improved displacement in the matrix. We observed that the steam enters the fracture and the matrix depending on whether the steam rate exceeds or not the critical values. The resulting condensed water also moves preferentially into the matrix or the fracture depending on the corresponding capillary number. Since steam is a non-wetting phase as a vapor, but becomes a wetting phase when condensed in a water-wet system, steam injection involves both drainage and imbibition. It was found that all of the oil trapped by the condensed water can be mobilized and recovered when in contact with steam. We also examined hot-water displacement. In comparison with cold-water experiments at the same capillary number, a higher sweep efficiency for both light and heavy oils was observed. It was found that the loam generated in the fracture during hot-water injection, is more stable than in steamflooding. Nonetheless, hot-water injection resulted into less efficient displacement in its absence.

Yortsos, Y.C.

1995-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "injection dsi systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Twin-Screw Extruder Development for the ITER Pellet Injection System  

SciTech Connect

The ITER pellet injection system is comprised of devices to form and accelerate pellets, and will be connected to inner wall guide tubes for fueling, and outer wall guide tubes for ELM pacing. An extruder will provide a stream of solid hydrogen isotopes to a secondary section, where pellets are cut and accelerated with a gas gun into the plasma. The ITER pellet injection system is required to provide a plasma fueling rate of 120 Pa-m3/s (900 mbar-L/s) and durations of up to 3000 s. The fueling pellets will be injected at a rate up to 10 Hz and pellets used to trigger ELMs will be injected at higher rates up to 20 Hz. A twin-screw extruder for the ITER pellet injection system is under development at the Oak Ridge National Laboratory. A one-fifth ITER scale prototype has been built and has demonstrated the production of a continuous solid deuterium extrusion. The 27 mm diameter, intermeshed, counter-rotating extruder screws are rotated at a rate up to ?5 rpm. Deuterium gas is pre-cooled and liquefied and solidified in separate extruder barrels. The precooler consists of a deuterium gas filled copper coil suspended in a separate stainless steel vessel containing liquid nitrogen. The liquefier is comprised of a copper barrel connected to a Cryomech AL330 cryocooler, which has a machined helical groove surrounded by a copper jacket, through which the pre-cooled deuterium condenses. The lower extruder barrel is connected to a Cryomech GB-37 cryocooler to solidify the deuterium (at ?15 K) before it is forced through the extruder die. The die forms the extrusion to a 3 mm x 4 mm rectangular cross section. Design improvements have been made to improve the pre-cooler and liquefier heat exchangers, to limit the loss of extrusion through gaps in the screws. This paper will describe the design improvements for the next iteration of the extruder prototype.

Meitner, Steven J [ORNL; Baylor, Larry R [ORNL; Combs, Stephen Kirk [ORNL; Fehling, Dan T [ORNL; McGill, James M [ORNL; Rasmussen, David A [ORNL; Leachman, J. W. [University of Wisconsin, Madison

2009-01-01T23:59:59.000Z

62

Collimation system for beam loss localization with slip stacking injection in the Fermilab Main Injector  

SciTech Connect

Slip stacking injection for high intensity operation of the Fermilab Main Injector produces a small fraction of beam which is not captured in buckets and accelerated. A collimation system has been implemented with a thin primary collimator to define the momentum aperture at which this beam is lost and four massive secondary collimators to capture the scattered beam. The secondary collimators define tight apertures and thereby capture a fraction of other lost beam. The system was installed in 2007 with commissioning continuing in 2008. The collimation system will be described including simulation, design, installation, and commissioning. Successful operation and operational limitations will be described.

Brown, Bruce C.; /Fermilab

2008-09-01T23:59:59.000Z

63

Research and development of hydrogen direct-injection internal combustion engine system  

Science Conference Proceedings (OSTI)

The research and development of hydrogen-internal combustion engine (ICE) system for heavy-duty trucks, with the goal of allowing carbon dioxide (CO2)-free operation in transportation department, has been carried out. The high-pressure hydrogen ... Keywords: NOx emission reduction, NOx storage reduction catalyst, carbon dioxide-free, direct injection, heavy-duty truck, high-pressure hydrogen injector, hydrogen, internal combustion engine

Yoshio Sato; Atsuhiro Kawamura; Tadanori Yanai; Kaname Naganuma; Kimitaka Yamane; Yasuo Takagi

2009-02-01T23:59:59.000Z

64

Noise Characterization of an Injection-Locked Titanium:sapphire Laser System  

E-Print Network (OSTI)

This thesis reports amplitude and frequency noise measurements of a Titanium:sapphire (Ti:sapphire) laser that is injection-locked with a low power diode laser. We use a heterodyne technique to frequency off-set lock a home built injection-locked Ti:sapphire laser with a low noise, commercial, injection-locked Ti:sapphire laser. Frequency noise measurements are made using the full-widthhalf-max of the two lasers ’ beat note. Amplitude noise measurements are made using the root mean square (rms) of the output of a photo diode. Under optimal conditions the rms amplitude noise is 1.0 % and the frequency noise is 300 kHz. The noise of our laser system depends on the feedback system characteristics. My contributions were the design and fabrication of a microwave interferometer, including its software and hardware, for the purpose of frequency off-set locking the two lasers. I also contributed to the data acquisition and analysis.

Daniel Adam Thrasher; Daniel Adam Thrasher

2013-01-01T23:59:59.000Z

65

High Pressure Coolant Injection (HPCI) system risk-based inspection guide: Pilgrim Nuclear Power Station  

Science Conference Proceedings (OSTI)

A review of the operating experience for the High Pressure Coolant Injection (HPCI) system at the Pilgrim Nuclear Power Station is described in this report. The information for this review was obtained from Pilgrim Licensee Event Reports (LERs) that were generated between 1980 and 1989. These LERs have been categorized into 23 failure modes that have been prioritized based on probabilistic risk assessment considerations. In addition, the results of the Pilgrim operating experience review have been compared with the results of of a similar, industry wide operating experience review. this comparison provides an indication of areas in the Pilgrim HPCI system that should be given increased attention in the prioritization of inspection resources.

Shier, W.; Gunther, W. (Brookhaven National Lab., Upton, NY (United States))

1992-10-01T23:59:59.000Z

66

IMPACT OF DME-DIESEL FUEL BLEND PROPERTIES ON DIESEL FUEL INJECTION SYSTEMS  

DOE Green Energy (OSTI)

The objectives of this research program are to develop information on lubricity and viscosity improvers and their impact on the wear mechanisms in fuel injectors operating on blends of dimethyl ether (DME) and diesel fuel. Since DME is a fuel with no lubricity (i.e., it does not possess the lubricating quality of diesel fuel), conventional fuel delivery and fuel injection systems are not compatible with dimethyl ether. Therefore, to operate a diesel engine on DME one must develop a fuel-tolerant injection system, or find a way to provide the necessary lubricity to the DME. In the shuttle bus project, we have chosen the latter strategy in order to achieve the objective with minimal need to modify the engine. Our strategy is to blend DME with diesel fuel, to obtain the necessary lubricity to protect the fuel injection system and to achieve low emissions. In this project, we have sought to develop methods for extending the permissible DME content in the DME-diesel blends without experiencing rapid injector failure due to wear. To date, our activities have covered three areas: examination of the impact of lubricity additives on the viscosity of DME, development of a high-pressure lubricity test apparatus for studies of lubricity and viscosity improvers and development of an injector durability stand for evaluation of wear rates in fuel injectors. This report provides summaries of the progress toward evaluation of the viscosity impacts of lubricity additives, completion of both experimental systems and a summary of the plan for completion of the project objectives.

Elana M. Chapman; Andre Boehman; Kimberly Wain; Wallis Lloyd; Joseph M. Perez; Donald Stiver; Joseph Conway

2003-06-01T23:59:59.000Z

67

10 CFR 830 Major Modification Determination for Emergency Firewater Injection System Replacement  

SciTech Connect

The continued safe and reliable operation of the ATR is critical to the Department of Energy (DOE) Office of Nuclear Energy (NE) mission. While ATR is safely fulfilling current mission requirements, a variety of aging and obsolescence issues challenge ATR engineering and maintenance personnel’s capability to sustain ATR over the long term. First documented in a series of independent assessments, beginning with an OA Environmental Safety and Health Assessment conducted in 2003, the issues were validated in a detailed Material Condition Assessment (MCA) conducted as a part of the ATR Life Extension Program in 2007.Accordingly, near term replacement of aging and obsolescent original ATR equipment has become important to ensure ATR capability in support of NE’s long term national missions. To that end, a mission needs statement has been prepared for a non-major system acquisition which is comprised of three interdependent sub-projects. The first project will replace the existent diesel-electrical bus (E-3), switchgear, and the fifty year old antiquated marine diesels with commercial power that is backed with safety-related emergency diesel generators (EDGs), switchgear, and uninterruptible power supply. The second project will replace the four, obsolete, original primary coolant pumps and motors. The third project, the subject of this major modification determination, will replace the current emergency firewater injection system (EFIS). The replacement water injection system will function as the primary emergency water injection system with the EFIS being retained as a defense-in-depth backup. Completion of this and the two other age-related projects (replacement of the ATR diesel bus (E-3) and switchgear and replacement of the existent aged primary coolant pumps and motors) will resolve major age-related operational issues plus make a significant contribution in sustaining the ATR safety and reliability profile. The major modification criteria evaluation of the project pre-conceptual design identified several issues that lead to the conclusion that the project is a major modification.

Noel Duckwitz

2011-05-01T23:59:59.000Z

68

IMPACT OF DME-DIESEL FUEL BLEND PROPERTIES ON DIESEL FUEL INJECTION SYSTEMS  

DOE Green Energy (OSTI)

The objectives of this research program are to develop information on lubricity and viscosity improvers and their impact on the wear mechanisms in fuel injectors operating on blends of dimethyl ether (DME) and diesel fuel. This project complements another ongoing project titled ''Development of a Dimethyl Ether (DME)-Fueled Shuttle Bus Demonstration Project''. The objectives of that research and demonstration program are to convert a campus shuttle bus to operation on dimethyl ether, a potential ultra-clean alternative diesel fuel. To accomplish this objective, this project includes laboratory evaluation of a fuel conversion strategy, as well as, field demonstration of the DME-fueled shuttle bus. Since DME is a fuel with no lubricity (i.e., it does not possess the lubricating quality of diesel fuel), conventional fuel delivery and fuel injection systems are not compatible with dimethyl ether. Therefore, to operate a diesel engine on DME one must develop a fuel-tolerant injection system, or find a way to provide the necessary lubricity to the DME. In the shuttle bus project, they have chosen the latter strategy in order to achieve the objective with minimal need to modify the engine. The strategy is to blend DME with diesel fuel, to obtain the necessary lubricity to protect the fuel injection system and to achieve low emissions. In this project, they have sought to develop methods for extending the permissible DME content in the DME-diesel blends without experiencing rapid injector failure due to wear. To date, the activities have covered two areas: development of a high-pressure lubricity test apparatus for studies of lubricity and viscosity improvers and development of an injector durability stand for evaluation of wear rates in fuel injectors. This report provides summaries of the progress toward completion of both experimental systems and a summary of the plan for completion of the project objectives.

Elana M. Chapman; Andre L. Boehman; Kimberly Wain; Wallis Lloyd; Joseph M. Perez; Donald Stiver; Joseph Conway

2002-07-01T23:59:59.000Z

69

Transverse electron transport in layered metallic systems: Giant magnetoresistance and injection of spins  

Science Conference Proceedings (OSTI)

The distribution functions for electrons differing in the sign of the spin projection and belonging to different layers (ferromagnetic and nonmagnetic) are determined from the system of Boltzmann kinetic equations. These functions make it possible to derive integral equations for electrochemical potentials for arbitrary ratios of characteristic lengths (layer thicknesses and momentum-and diffusion mean free paths) and to describe transverse electron transport both in the bulk and in the surface regions of the multilayer structure. The expressions for the effective contact resistance are derived and the value of the transverse ohmic resistance of the structure is found, as well as its spin-dependent part determined by the values of injection factors {gamma}. The values of nonequilibrium spin polarizations, which are also connected with coefficients {gamma}, are determined. The values of {gamma} are calculated for various relations between the characteristic parameters of the given system and for various types of magnetic order.

Kravchenko, V. Ya. [Russian Academy of Sciences, Institute of Solid State Physics (Russian Federation)], E-mail: krav@issp.ac.ru

2006-05-15T23:59:59.000Z

70

A desiccant/steam-injected gas-turbine industrial cogeneration system  

SciTech Connect

An integrated desiccant/steam-injected gas-turbine system was evaluated as an industrial cogenerator for the production of electricity and dry, heated air for product drying applications. The desiccant can be regenerated using the heated, compressed air leaving the compressor. The wet stream leaves the regenerator at a lower temperature than when it entered the desiccant regenerator, but with little loss of energy. The wet stream returns to the combustion chamber of the gas-turbine system after preheating by exchanging heat with the turbine exhaust strewn. Therefore, the desiccant is regenerated virtually energy-free. In the proposed system, the moisture-laden air exiting the desiccant is introduced into the combustion chamber of the gas-turbine power system. This paper discusses various possible design configurations, the impact of increased moisture content on the combustion process, the pressure drop across the desiccant regenerator, and the impact of these factors on the overall performance of the integrated system. A preliminary economic analysis including estimated potential energy savings when the system is used in several drying applications, and equipment and operating costs are also presented.

Jody, B.J.; Daniels, E.J.; Karvelas, D.E.; Teotia, A.P.S.

1993-12-31T23:59:59.000Z

71

A desiccant/steam-injected gas-turbine industrial cogeneration system  

SciTech Connect

An integrated desiccant/steam-injected gas-turbine system was evaluated as an industrial cogenerator for the production of electricity and dry, heated air for product drying applications. The desiccant can be regenerated using the heated, compressed air leaving the compressor. The wet stream leaves the regenerator at a lower temperature than when it entered the desiccant regenerator, but with little loss of energy. The wet stream returns to the combustion chamber of the gas-turbine system after preheating by exchanging heat with the turbine exhaust strewn. Therefore, the desiccant is regenerated virtually energy-free. In the proposed system, the moisture-laden air exiting the desiccant is introduced into the combustion chamber of the gas-turbine power system. This paper discusses various possible design configurations, the impact of increased moisture content on the combustion process, the pressure drop across the desiccant regenerator, and the impact of these factors on the overall performance of the integrated system. A preliminary economic analysis including estimated potential energy savings when the system is used in several drying applications, and equipment and operating costs are also presented.

Jody, B.J.; Daniels, E.J.; Karvelas, D.E.; Teotia, A.P.S.

1993-01-01T23:59:59.000Z

72

Coal-water slurry spray characteristics of an electronically-controlled accumulator fuel injection system  

Science Conference Proceedings (OSTI)

Experiments have been complete to characterize coal-water slurry sprays from a electronically-controlled accumulator fuel injection system of diesel engine. The sprays were injected into a pressurized chamber equipped with windows. High speed movies, fuel pressures and needle lifts were obtained as a function of time, orifice diameter, coal loading, gas density in the chamber, and accumulator fuel pressure. For the base conditions 50% (by mass) coal loading, 0.4 mm diameter nozzle hole, coal-water slurry pressure of 82 MPa (12,000 psi), and a chamber density of 25 kg/m{sup 3}, the break-up time was 0. 30 ms. An empirical correlation for both spray tip penetration and initial jet velocity was developed. For the conditions of this study, the spray tip penetration and initial jet velocity were 15% greater for coal-water slurry than for diesel fuel or water. Cone angles of the sprays were dependent on the operating conditions and fluid, as well as the time and locations of the measurement. The time-averaged cone angle for the base case conditions was 13.6{degree}. Results of this study and the correlation are specific to the tested coal-water slurry and are not general for other coal-water slurry fuels.

Caton, J.A.; Payne, S.E.; Terracina, D.P.; Kihm, K.D. [Texas A and M Univ., College Station, TX (United States). Dept. of Mechanical Engineering

1993-12-31T23:59:59.000Z

73

IMPACT OF DME-DIESEL FUEL BLEND PROPERTIES ON DIESEL FUEL INJECTION SYSTEMS  

DOE Green Energy (OSTI)

The objectives of this research program are to develop information on lubricity and viscosity improvers and their impact on the wear mechanisms in fuel injectors operating on blends of dimethyl ether (DME) and diesel fuel. Since DME is a fuel with no lubricity (i.e., it does not possess the lubricating quality of diesel fuel), conventional fuel delivery and fuel injection systems are not compatible with dimethyl ether. Therefore, to operate a diesel engine on DME one must develop a fuel-tolerant injection system, or find a way to provide the necessary lubricity to the DME. In the shuttle bus project, we have chosen the latter strategy in order to achieve the objective with minimal need to modify the engine. Our strategy is to blend DME with diesel fuel, to obtain the necessary lubricity to protect the fuel injection system and to achieve low emissions. In this project, we have sought to develop methods for extending the permissible DME content in the DME-diesel blends without experiencing rapid injector failure due to wear. Our activities have covered three areas: examination of the impact of lubricity additives on the viscosity of DME, development of a high-pressure lubricity test apparatus for studies of lubricity and viscosity improvers and development of an injector durability stand for evaluation of wear rates in fuel injectors. The first two of these areas have resulted in valuable information about the limitations of lubricity and viscosity additives that are presently available in terms of their impact on the viscosity of DME and on wear rates on injector hardware. The third area, that of development of an injector durability test stand, has not resulted in a functioning experiment. Some information is provided in this report to identify the remaining tasks that need to be performed to make the injector stand operational. The key observations from the work are that when blended at 25 wt.% in either diesel fuel or Biodiesel fuel, DME requires more than 5 wt.% additive of all viscosity and lubricity additives tested here to even approach the lower limit of the ASTM diesel fuel viscosity requirement. To treat neat DME sufficiently to make DME comply with the ASTM diesel fuel viscosity requirement would require a viscosity additive with 10{sup 45} cSt viscosity, which is not possible with current additive technologies.

Elana M. Chapman; Andre Boehman; Kimberly Wain; Wallis Lloyd; Joseph M. Perez; Donald Stiver; Joseph Conway

2004-04-01T23:59:59.000Z

74

IMPACT OF DME-DIESEL FUEL BLEND PROPERTIES ON DIESEL FUEL INJECTION SYSTEMS  

Office of Scientific and Technical Information (OSTI)

Annual Technical Progress Report for Project Entitled "Impact Annual Technical Progress Report for Project Entitled "Impact of DME-Diesel Fuel Blend Properties on Diesel Fuel Injection Systems" May 16, 2002 - May 15, 2003 Elana M. Chapman, Andre Boehman, Kimberly Wain, Wallis Lloyd, Joseph M. Perez, Donald Stiver, Joseph Conway Report Issue Date: June 2003 DOE Award Number: DE-FC26-01NT41115 The Pennsylvania State University The Energy Institute University Park, PA 16802 ii DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus,

75

Initial Results in Power System Identification from Injected Probing Signals Using a Subspace Method  

SciTech Connect

In this paper, the authors use the Numerical algorithm for Subspace State Space System IDentification (N4SID) to extract dynamic parameters from phasor measurements collected on the western North American Power Grid. The data were obtained during tests on June 7, 2000, and they represent wide area response to several kinds of probing signals including Low-Level Pseudo-Random Noise (LLPRN) and Single-Mode Square Wave (SMSW) injected at the Celilo terminal of the Pacific HVDC In-tertie (PDCI). An identified model is validated using a cross vali-dation method. Also, the obtained electromechanical modes are compared with the results from Prony analysis of a ringdown and with signal analysis of ambient data measured under similar op-erating conditions. The consistent results show that methods in this class can be highly effective even when the probing signal is small.

Zhou, Ning; Pierre, John W.; Hauer, John F.

2006-08-01T23:59:59.000Z

76

Blast Furnace Granulated Coal Injection System Demonstration Project: A DOE Assessment  

NLE Websites -- All DOE Office Websites (Extended Search)

2 2 Blast Furnace Granulated Coal Injection System Demonstration Project: A DOE Assessment June 2000 U. S. Department of Energy National Energy Technology Laboratory P.O. Box 880, 3610 Collins Ferry Road Morgantown, WV 26507-0880 and P.O. Box 10940, 626 Cochrans Mill Road Pittsburgh, PA 15236-0940 2 Disclaimer This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference therein

77

System to inject steam and produce oil from the same wellbore through downhole valve switching  

SciTech Connect

Various Downhole Equipment systems have been designed for typical applications in three California Oilfields,based on well data gathered from three different Operating Companies. The first system, applicable to a 2,000 ft deep reservoir (Monarch) a highly underpressured, unconsolidated sand of 200 ft net pay, located in the Midway-Sunset field, is based on the use of a new well. The second well configuration considered was the re-entry into an existing well equipped with a 7 inches casing and penetrating into two separate sandstone reservoirs, at normal pressures in the North Antelope Hills field. Only the bottom layer is presently in production through a gravel-packed 5.5 inch linear, while the upper zone is behind the cemented casing. The third case studied was the re-entry into an existing well equipped with an 8 5/8 inch casing, presently unperforated, into a thin under-pressured sand reservoir (Weber) in the Midway-Sunset field. All three California fields contain Heavy Oils of different but relatively high viscosities. A new class of potential applications of our new technology has also been considered: the recovery of Light Oil (> 20 API) by steam injection in under-pressured Carbonate reservoirs which lay at depths beyond the economic limit for conventional steam injection technology. The possibility of including this application in a Field Test proposal to the DOE, under the Class II Oil Program, is now under review by various Operators. A drilling contractor experienced in drilling multiple horizontal wells in Carbonate reservoirs and a team of reservoir engineers experienced in the recovery of Light Oil by steam in fractured reservoirs have expressed their interest in participating in such a joint Field Project. Laboratory tests on specific prototypes of Downhole Sealing Elements are underway.

Not Available

1992-01-01T23:59:59.000Z

78

Fuel injection system and method of operating the same for an engine  

DOE Patents (OSTI)

A fuel injector is coupled to an engine. The fuel injector includes an injection opening configured to vary in cross-section between a open state and a fully closed state. The fuel injector is configured to provide a plurality of discrete commanded fuel injections into an engine cylinder by modulating the size of the injection opening without completely closing the opening to the fully closed state.

Topinka, Jennifer Ann (Niskayuna, NY); DeLancey, James Peter (Corinth, NY); Primus, Roy James (Niskayuna, NY); Pintgen, Florian Peter (Niskayuna, NY)

2011-02-15T23:59:59.000Z

79

Testing of a new aftertreatment system for lean burn direct injected gasoline engines.  

E-Print Network (OSTI)

??A gasoline direct injected engine operating under lean conditions can offer a reduction in fuel consumption and a reduction of CO2 emissions but meanwhile suffer… (more)

Thulin, Andeas

2011-01-01T23:59:59.000Z

80

Development of a Twin-Screw D-2 Extruder for the ITER Pellet Injection System  

SciTech Connect

A twin-screw extruder for the ITER pellet injection system is under development at the Oak Ridge National Laboratory. The extruder will provide a stream of solid hydrogen isotopes to a secondary section, where pellets are cut and accelerated with single-stage gas gun into the plasma. A one-fifth ITER scale prototype extruder has been built to produce a continuous solid deuterium extrusion. Deuterium gas is precooled and liquefied before being introduced into the extruder. The precooler consists of a copper vessel containing liquid nitrogen surrounded by a deuterium gas filled copper coil. The liquefier is comprised of a copper cylinder connected to a Cryomech AL330 cryocooler, which is surrounded by a copper coil that the precooled deuterium flows through. The lower extruder barrel is connected to a Cryomech GB-37 cryocooler to solidify the deuterium (at approximate to 15 K) before it is forced through the extruder nozzle. A viewport located below the extruder nozzle provides a direct view of the extrusion. A camera is used to document the extrusion quality and duration. A data acquisition system records the extruder temperatures, torque, and speed, upstream, and downstream pressures. This paper will describe the prototype twin-screw extruder and initial extrusion results.

Meitner, Steven J [ORNL; Baylor, Larry R [ORNL; Carbajo, Juan J [ORNL; Combs, Stephen Kirk [ORNL; Fehling, Dan T [ORNL; Foust, Charles R [ORNL; McFee, Marshall T [ORNL; McGill, James M [ORNL; Rasmussen, David A [ORNL; Sitterson, R G [ORNL; Sparks, Dennis O [ORNL; Qualls, A L [ORNL

2009-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "injection dsi systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Beam injection into RHIC  

SciTech Connect

During the RHIC sextant test in January 1997 beam was injected into a sixth of one of the rings for the first time. The authors describe the injection zone and its bottlenecks. They report on the commissioning of the injection system, on beam based measurements of the kickers and the application program to steer the beam.

Fischer, W.; Hahn, H.; MacKay, W.W.; Satogata, T.; Tsoupas, N.; Zhang, W.

1997-07-01T23:59:59.000Z

82

The TORE SUPRA Cryogenic System Behaviour During Long Plasma Discharges with a High Injected Energy  

Science Conference Proceedings (OSTI)

After the CIEL project completion including the upgrade of the plasma facing components and the water cooling system, the superconducting Tore Supra Tokamak achieved a world record of injected energy (1.1 GJ), during long duration (6 min) plasma discharges, which was enabled by the upgrade of the transfer system capacities, but also by the steady state toroidal field. The Tore Supra cryogenic refrigerator enables the toroidal field coils to be operated at nominal current along the full daily plasma operation shift. It has capacities of 300 W at 1.8 K, 750 W at 4.5 K and 30 kW at 80 K and was operated with a high reliability for more than 16 years. After a brief recall on the cryogenic refrigeration of the toroidal superconducting magnet, the distribution of the heat loads at the various levels of temperature (in standby mode 150W at 1.8 K and 200W at 4.5 K) is presented. The inventory of the calculated static and variable heat loads deposited within each part of toroidal field coils and thermal shields, is given with the factors of dependence. This analysis identifies and quantifies the major magnetic disturbances like a disruption (about 12 kJ onto the coils and 300 kJ onto the thick casings) which generate additional heat loads for the refrigerator.The measurements associated with the He II saturated bath pumping system, and the supercritical helium loop cooling the thick casings, allow us to verify thereafter the behaviour of the cryo-refrigerator during the long duration discharges, and the compliance with the theoretical model.The conclusions bring results also applicable to the cyoplant of future plant like ITER which will operate with long duration discharges.

Henry, D.; Hertout, P.; Journeaux, J. Y.; Duchateau, J. L.; Reynaud, P. [Departement de Recherches sur la Fusion Controlee, Association, Euratom-CEA, CEA/Cadarache, F-13108 Saint Paul-lez-Durance (France)

2006-04-27T23:59:59.000Z

83

Evaluation of C-14 as a natural tracer for injected fluids at the Aidlin sector of The Geysers geothermal system through modeling of mineral-water-gas Reactions  

E-Print Network (OSTI)

breakthrough observed in geothermal systems (e.g. , Shook,recharge project, Geysers geothermal field, California, USA,media: Applications to geothermal injectivity and CO 2

Dobson, Patrick; Sonnenthal, Eric; Lewicki, Jennifer; Kennedy, Mack

2006-01-01T23:59:59.000Z

84

Methods, systems and apparatus for optimization of third harmonic current injection in a multi-phase machine  

DOE Patents (OSTI)

Methods, system and apparatus are provided for increasing voltage utilization in a five-phase vector controlled machine drive system that employs third harmonic current injection to increase torque and power output by a five-phase machine. To do so, a fundamental current angle of a fundamental current vector is optimized for each particular torque-speed of operating point of the five-phase machine.

Gallegos-Lopez, Gabriel

2012-10-02T23:59:59.000Z

85

Modeling Single Well Injection-Withdrawal (SWIW) Tests for Characterization of Complex Fracture-Matrix Systems  

Science Conference Proceedings (OSTI)

The ability to reliably predict flow and transport in fractured porous rock is an essential condition for performance evaluation of geologic (underground) nuclear waste repositories. In this report, a suite of programs (TRIPOLY code) for calculating and analyzing flow and transport in two-dimensional fracture-matrix systems is used to model single-well injection-withdrawal (SWIW) tracer tests. The SWIW test, a tracer test using one well, is proposed as a useful means of collecting data for site characterization, as well as estimating parameters relevant to tracer diffusion and sorption. After some specific code adaptations, we numerically generated a complex fracture-matrix system for computation of steady-state flow and tracer advection and dispersion in the fracture network, along with solute exchange processes between the fractures and the porous matrix. We then conducted simulations for a hypothetical but workable SWIW test design and completed parameter sensitivity studies on three physical parameters of the rock matrix - namely porosity, diffusion coefficient, and retardation coefficient - in order to investigate their impact on the fracture-matrix solute exchange process. Hydraulic fracturing, or hydrofracking, is also modeled in this study, in two different ways: (1) by increasing the hydraulic aperture for flow in existing fractures and (2) by adding a new set of fractures to the field. The results of all these different tests are analyzed by studying the population of matrix blocks, the tracer spatial distribution, and the breakthrough curves (BTCs) obtained, while performing mass-balance checks and being careful to avoid some numerical mistakes that could occur. This study clearly demonstrates the importance of matrix effects in the solute transport process, with the sensitivity studies illustrating the increased importance of the matrix in providing a retardation mechanism for radionuclides as matrix porosity, diffusion coefficient, or retardation coefficient increase. Interestingly, model results before and after hydrofracking are insensitive to adding more fractures, while slightly more sensitive to aperture increase, making SWIW tests a possible means of discriminating between these two potential hydrofracking effects. Finally, we investigate the possibility of inferring relevant information regarding the fracture-matrix system physical parameters from the BTCs obtained during SWIW testing.

Cotte, F.P.; Doughty, C.; Birkholzer, J.

2010-11-01T23:59:59.000Z

86

Synchronized droplet size measurements for coal-water-slurry (CWS) diesel sprays of an electronically-controlled fuel injection system  

DOE Green Energy (OSTI)

Experiments were completed to study intermittent coal-water slurry (CWS) fuel sprays injected from an electronically-controlled accumulator injector system. A laser diffraction particle analyzing (LDPA) technique was used to measure the spray diameters (Sauter mean diameter, SMD) assuming the Rosin-Rammler two parameter model. In order to ensure an accurate synchronization of the measurement with the intermittent sprays, a new synchronization technique was developed using the light extinction signal as a triggering source for the data taking initiation. This technique allowed measurement of SMDs near the spray tip where the light extinction was low and the data were free from the multiscattering bias. Coal-water slurry fuel with 50% coal loading in mass containing 5 {mu}m mass median diameter coal particulates was considered. Injection pressures ranging from 28 to 110 MPa, two different nozzle orifice diameters, 0.2 ad 0.4 mm, and four axial measurement locations from 60 to 120 mm from the nozzle orifice were studied. Measurements were made for pressurized (2.0 MPa in gauge) and for ambient chamber conditions. The spray SMD showed an increase with the distance of the axial measurement location and with the ambient gas density, and showed a decrease with increasing injection pressure. A correlation of the Sauter mean diameter with the injection conditions was determined. The results were also compared with previous SMD correlations that were available only for diesel fuel sprays.

Kihm, K.D.; Terracina, D.P.; Payne, S.E.; Caton, J.A. [Texas A and M Univ., College Station, TX (United States). Dept. of Mechanical Engineering

1993-12-31T23:59:59.000Z

87

High Pressure Coolant Injection (HPCI) System Risk-Based Inspection Guide for Browns Ferry Nuclear Power Station  

Science Conference Proceedings (OSTI)

The High Pressure Coolant Injection (HPCI) system has been examined from a risk perspective. A System Risk-Based Inspection Guide (S-RIG) has been developed as an aid to HPCI system inspections at the Browns Ferry Nuclear Power Plant, Units 1, 2 and 3. The role of. the HPCI system in mitigating accidents is discussed in this S-RIG, along with insights on identified risk-based failure modes which could prevent proper operation of the system. The S-RIG provides a review of industry-wide operating experience, including plant-specific illustrative examples to augment the PRA and operational considerations in identifying a catalogue of basic PRA failure modes for the HPCI system. It is designed to be used as a reference for routine inspections, self-initiated safety system functional inspections (SSFIs), and the evaluation of risk significance of component failures at the nuclear power plant.

Wong, S.; DiBiasio, A.; Gunther, W. [Brookhaven National Lab., Upton, NY (United States)

1993-09-01T23:59:59.000Z

88

Ignition assist systems for direct-injected, diesel cycle, medium-duty alternative fuel engines: Final report phase 1  

DOE Green Energy (OSTI)

This report is a summary of the results of Phase 1 of this contract. The objective was to evaluate the potential of assist technologies for direct-injected alternative fuel engines vs. glow plug ignition assist. The goal was to demonstrate the feasibility of an ignition system life of 10,000 hours and a system cost of less than 50% of the glow plug system, while meeting or exceeding the engine thermal efficiency obtained with the glow plug system. There were three tasks in Phase 1. Under Task 1, a comprehensive review of feasible ignition options for DING engines was completed. The most promising options are: (1) AC and the ''SmartFire'' spark, which are both long-duration, low-power (LDLP) spark systems; (2) the short-duration, high-power (SDHP) spark system; (3) the micropilot injection ignition; and (4) the stratified charge plasma ignition. Efforts concentrated on investigating the AC spark, SmartFire spark, and short-duration/high-power spark systems. Using proprietary pricing information, the authors predicted that the commercial costs for the AC spark, the short-duration/high-power spark and SmartFire spark systems will be comparable (if not less) to the glow plug system. Task 2 involved designing and performing bench tests to determine the criteria for the ignition system and the prototype spark plug for Task 3. The two most important design criteria are the high voltage output requirement of the ignition system and the minimum electrical insulation requirement for the spark plug. Under Task 3, all the necessary hardware for the one-cylinder engine test was designed. The hardware includes modified 3126 cylinder heads, specially designed prototype spark plugs, ignition system electronics, and parts for the system installation. Two 3126 cylinder heads and the SmartFire ignition system were procured, and testing will begin in Phase 2 of this subcontract.

Chan, A.K.

2000-02-23T23:59:59.000Z

89

Geysers injection modeling  

DOE Green Energy (OSTI)

Our research is concerned with mathematical modeling techniques for engineering design and optimization of water injection in vapor-dominated systems. The emphasis in the project has been on the understanding of physical processes and mechanisms during injection, applications to field problems, and on transfer of numerical simulation capabilities to the geothermal community. This overview summarizes recent work on modeling injection interference in the Southeast Geysers, and on improving the description of two-phase flow processes in heterogeneous media.

Pruess, K.

1994-04-01T23:59:59.000Z

90

Identification of limiting case between DBA and SBDBA (CL break area sensitivity): A new model for the boron injection system  

SciTech Connect

Atucha-2 is a Siemens-designed PHWR reactor under construction in the Republic of Argentina. Its geometrical complexity and (e.g., oblique Control Rods, Positive Void coefficient) required a developed and validated complex three dimensional (3D) neutron kinetics (NK) coupled thermal hydraulic (TH) model. Reactor shut-down is obtained by oblique CRs and, during accidental conditions, by an emergency shut-down system (JDJ) injecting a highly concentrated boron solution (boron clouds) in the moderator tank, the boron clouds reconstruction is obtained using a CFD (CFX) code calculation. A complete LBLOCA calculation implies the application of the RELAP5-3D{sup C} system code. Within the framework of the third Agreement 'NA-SA - Univ. of Pisa' a new RELAP5-3D control system for the boron injection system was developed and implemented in the validated coupled RELAP5-3D/NESTLE model of the Atucha 2 NPP. The aim of this activity is to find out the limiting case (maximum break area size) for the Peak Cladding Temperature for LOCAs under fixed boundary conditions. (authors)

Gonzalez Gonzalez, R.; Petruzzi, A.; D'Auria, F. [San Piero A Grado Nuclear Research Group GRNSPG, Univ. of Pisa, Via Livornese 1291-56122, San Piero a Grado - Pisa (Italy); Mazzantini, O. [Nucleo-electrica Argentina Sociedad Anonima (NA-SA), Buenos Aires (Argentina)

2012-07-01T23:59:59.000Z

91

State and National Energy and Environmental Risk Analysis Systems for underground injection control. Summary annual report, April 1992--April 1993  

SciTech Connect

ICF Resources` project, entitled {open_quotes}State and National Energy and Environmental Risk Analysis Systems for Underground Injection Control{close_quotes} includes two primary tasks (development of state and national systems respectively) and a technology transfer element. The state system was designed to assist states with data management related to underground injection control (UIC). However, during the current period, external changes (primarily pending regulatory changes at the federal level) have made the risk assessment protocol aspect of the state system of increased importance relative to data management. This protocol would assess the relative risk of groundwater contamination due to UIC activities in various areas of the state. The risk assessment system could be used to assist states in allocating scarce resources and potentially could form the analytical basis of a state variance program to respond to pending federal regulatory changes. Consequently, a substantial portion of the effort to date has been focused on this aspect of the project, The national energy and environmental risk analysis system (EERAS) is designed to enhance DOE`s analytical capabilities. This concept will be demonstrated using UIC data. The initial system design for EERAS has been completed but may be revised based on input from DOE and on the pending UIC regulatory changes. Data have been collected and organized and can be input once the file structure is finalized. The further development options for EERAS defined as part of this project will allow for the full development of the system beyond the current prototype phase which will enhance DOE`s analytical capabilities for responding to regulatory initiatives and for evaluating the benefits of risk-based regulatory approaches.

Haas, M.R.

1993-04-01T23:59:59.000Z

92

Simulation Environment for Development and Testing of Plug Compatible Power System Applications  

E-Print Network (OSTI)

by a number of suppliers including ABB, DSI, Incremental Systems, NSR, Siemens, Telegyr and Transdyn Controls, are introduced. The models in the EPRI OTS can be broadly divided into the following categories: Powerplant fossil, hydro, gas turbine, and nuclear units. Loads can be modeled using a combination of constant

93

RF plasma sources for neutral-beam-injection systems. Phase I: definition study. Final report  

DOE Green Energy (OSTI)

The key design issues driving the selection of a plasma generation method are discussed. The main programmatic issue in source selection was ease of implementation on existing and planned neutral beam systems. The two source concepts selected for detailed consideration, one employing electron cyclotron heating at microwave frequencies and one employing radio frequency induction heating, are described. Preliminary RFI hydrogen discharge experiments in a geometry suitable for neutral beam system application are described.

Not Available

1981-11-01T23:59:59.000Z

94

System to inject steam and produce oil from the same wellbore through downhole valve switching. First quarterly report  

SciTech Connect

Various Downhole Equipment systems have been designed for typical applications in three California Oilfields,based on well data gathered from three different Operating Companies. The first system, applicable to a 2,000 ft deep reservoir (Monarch) a highly underpressured, unconsolidated sand of 200 ft net pay, located in the Midway-Sunset field, is based on the use of a new well. The second well configuration considered was the re-entry into an existing well equipped with a 7 inches casing and penetrating into two separate sandstone reservoirs, at normal pressures in the North Antelope Hills field. Only the bottom layer is presently in production through a gravel-packed 5.5 inch linear, while the upper zone is behind the cemented casing. The third case studied was the re-entry into an existing well equipped with an 8 5/8 inch casing, presently unperforated, into a thin under-pressured sand reservoir (Weber) in the Midway-Sunset field. All three California fields contain Heavy Oils of different but relatively high viscosities. A new class of potential applications of our new technology has also been considered: the recovery of Light Oil (> 20 API) by steam injection in under-pressured Carbonate reservoirs which lay at depths beyond the economic limit for conventional steam injection technology. The possibility of including this application in a Field Test proposal to the DOE, under the Class II Oil Program, is now under review by various Operators. A drilling contractor experienced in drilling multiple horizontal wells in Carbonate reservoirs and a team of reservoir engineers experienced in the recovery of Light Oil by steam in fractured reservoirs have expressed their interest in participating in such a joint Field Project. Laboratory tests on specific prototypes of Downhole Sealing Elements are underway.

Not Available

1992-10-01T23:59:59.000Z

95

Development of a direct-injected natural gas engine system for heavy-duty vehicles: Final report phase 2  

DOE Green Energy (OSTI)

This report summarizes the results of Phase 2 of this contract. The authors completed four tasks under this phase of the subcontract. (1) They developed a computational fluid dynamics (CFD) model of a 3500 direct injected natural gas (DING) engine gas injection/combustion system and used it to identify DING ignition/combustion system improvements. The results were a 20% improvement in efficiency compared to Phase 1 testing. (2) The authors designed and procured the components for a 3126 DING engine (300 hp) and finished assembling it. During preliminary testing, the engine ran successfully at low loads for approximately 2 hours before injector tip and check failures terminated the test. The problems are solvable; however, this phase of the program was terminated. (3) They developed a Decision & Risk Analysis model to compare DING engine technology with various other engine technologies in a number of commercial applications. The model shows the most likely commercial applications for DING technology and can also be used to identify the sensitivity of variables that impact commercial viability. (4) MVE, Inc., completed a preliminary design concept study that examines the major design issues involved in making a reliable and durable 3,000 psi LNG pump. A primary concern is the life of pump seals and piston rings. Plans for the next phase of this program (Phase 3) have been put on indefinite hold. Caterpillar has decided not to fund further DING work at this time due to limited current market potential for the DING engine. However, based on results from this program, the authors believe that DI natural gas technology is viable for allowing a natural gas-fueled engine to achieve diesel power density and thermal efficiency for both the near and long terms.

Cox, G.B.; DelVecchio, K.A.; Hays, W.J.; Hiltner, J.D.; Nagaraj, R.; Emmer, C.

2000-03-02T23:59:59.000Z

96

Experimental Study of Non-thermal Plasma Injection System Converting NOx in Simulated Diesel Emissions  

Science Conference Proceedings (OSTI)

In order to study the removal effect of non-thermal plasma (NTP) after-treatment system on diesel engine harmful emissions, a dielectric barrier discharge (DBD) plasma reactor is designed, and the NOx removal effect is studied under the conditions of ... Keywords: Non-thermal Plasma(NTP), Dielectric Barrier Discharge(DBD, Diesel Engine, Nox

Jing Wang; Yixi Cai; Jun Wang; Dongli Ran

2010-11-01T23:59:59.000Z

97

Verification of the NOAA Smoke Forecasting System: Model Sensitivity to the Injection Height  

Science Conference Proceedings (OSTI)

A detailed evaluation of NOAA’s Smoke Forecasting System (SFS) is a fundamental part of its development and further refinement. In this work, particulate matter with a diameter less than or equal to 2.5-?m (PM2.5) concentration levels, simulated ...

Ariel F. Stein; Glenn D. Rolph; Roland R. Draxler; Barbara Stunder; Mark Ruminski

2009-04-01T23:59:59.000Z

98

Achieve Continuous Injection of Solid Fuels into Advanced Combustion System Pressures  

SciTech Connect

The overall objective of this project is the development of a mechanical rotary-disk feeder, known as the Stamet Posimetric High Pressure Solids Feeder System, to demonstrate feeding of dry granular coal continuously and controllably into pressurized environments of up to 70 kg/cm2 (1,000 psi). This is the Phase III of the ongoing program. Earlier Phases 1 and II successfully demonstrated feeding into pressures up to 35 kg/cm{sup 2} (500 psi). The final report for those phases was submitted in April 2005. Based on the previous work done in Phases I & II using Powder River Basin coal provided by the PSDF facility in Wilsonville, AL, a Phase III feeder system was designed and built to accomplish the target of feeding the coal into a pressure of 70 kg/cm2 (1,000 psi) and to be capable of feed rates of up to 550 kilograms (1,200lbs) per hour. The drive motor system from Phase II was retained for use on Phase III since projected performance calculations indicated it should be capable of driving the Phase III pump to the target levels. The pump & motor system was installed in a custom built test rig comprising an inlet vessel containing an active live-wall hopper mounted on weigh cells in a support frame, transition into the pump inlet, transition from pump outlet and a receiver vessel containing a receiver drum supported on weigh cells. All pressure containment on the rig was rated to105 kg/cm{sup 2} (1,500psi) to accommodate the final pressure requirement of a proposed Phase IV of the program. A screw conveyor and batch hopper were added to transfer coal at atmospheric pressure from the shop floor up into the test rig to enable continuous feeding up to the capacity of the receiving vessel. Control & monitoring systems were up-rated from the Phase II system to cover the additional features incorporated in the Phase III rig, and provide closer control and expanded monitoring of the entire system. A program of testing and modification was carried out in Stamet's facility in CA, culminating in the first successful feeding of coal into the Phase III target of 70 kg/cm{sup 2} (1,000 psi) gas pressure in March 2007. Subsequently, repeated runs at pressure were achieved, and comparison of the data with Phase II results when adjusted for scale differences showed further power reductions of 40% had been achieved from the final Phase II pressure runs. The general design layout of a commercial-scale unit was conducted, and preliminary cost estimates made.

Derek L. Aldred; Timothy Saunders

2007-03-31T23:59:59.000Z

99

Achieve Continuous Injection of Solid Fuels into Advanced Combustion System Pressures  

SciTech Connect

The overall objective of this project is the development of a mechanical rotary-disk feeder, known as the Stamet Posimetric High Pressure Solids Feeder System, to feed dry granular coal continuously and controllably into pressurized environments of up to 35 kg/cm{sup 2} (500 psi). This was to be accomplished in two phases. The first task was to review materials handling experience in pressurized operations as it related to the target pressures for this project, and review existing coal preparation processes and specifications currently used in advanced combustion systems. Samples of existing fuel materials were obtained and tested to evaluate flow, sealing and friction properties. This provided input data for use in the design of the Stamet Feeders for the project, and ensured that the material specification used met the requirements of advanced combustion & gasification systems. Ultimately, Powder River Basin coal provided by the PSDF facility in Wilsonville, AL was used as the basis for the feeder design and test program. Based on the material property information, a Phase 1 feeder system was designed and built to accomplish feeding the coal to an intermediate pressure up to 21 kg/cm{sup 2} (300 psi) at feed rates of approximately 100 kilograms (220lbs) per hour. The pump & motor system was installed in a custom built test rig comprising an inlet vessel containing an active live-wall hopper mounted in a support frame, transition into the pump inlet, transition from pump outlet and a receiver vessel containing a receiver drum supported on weigh cells. All pressure containment on the rig was rated for the final pressure requirement of 35 kg/cm{sup 2} (500psi). A program of testing and modification was carried out in Stamet's facility in CA, culminating in successful feeding of coal into the Phase 1 target of 21 kg/cm{sup 2} (300psi) gas pressure in December 2003. Further testing was carried out at CQ Inc's facility in PA, providing longer run times and experience of handling and feeding the coal in winter conditions. Based on the data developed through the testing of the Phase I unit, a Phase II system was designed for feeding coal into pressures of up to 35 kg/cm{sup 2} (500 psi). A further program of testing and modification was then carried out in Stamet's facility, with the target pressure being achieved in January 2005. Repeated runs at pressure were achieved, and optimization of the machine resulted in power reductions of 60% from the first successful pressure runs. General design layout of a commercial-scale unit was conducted, and preliminary cost estimates for a commercial unit obtained.

Derek L. Aldred; Timothy Saunders

2005-07-01T23:59:59.000Z

100

Imaging of reservoirs and fracture systems using microearthquakes induced by hydraulic injections  

DOE Green Energy (OSTI)

Predicting the future performance of a geothermal reservoir and planning a strategy for increasing productivity from the reservoir require an intimate knowledge of the fracture system through which geothermal fluids permeate. Microearthquakes often accompany hydraulic fracturing as well as normal production activities in geothermal fields. The waveforms from the se microearthquakes provide valuable information that can be used to infer the three-dimensional structure of the fracture system in the reservoir. The locations of the microearthquakes can be used to infer the presence of large fractures along which shear slip has occurred. Tomographic imaging using arrival times of the seismic waves, provides a three-dimensional image of the P and S wave velocity structure of the reservoir. These velocities yield information about the presence of microfractures in the rock. Waveform stacking methods can be used to both corroborate seismic velocities and image seismic scatters in the reservoir. The most prominent seismic scatters are likely to be fluid-filled fractures. Thus, seismic data provide information about a fractures over a large scale range which can be of use in reservoir engineering. 32 refs., 4 figs.

Fehler, M.; House, L.; Phillips, W.S. (Los Alamos National Lab., NM (USA)); Block, L.; Cheng, C.H. (Massachusetts Inst. of Tech., Cambridge, MA (USA). Earth Resources Lab.)

1991-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "injection dsi systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Safety Design Strategy for the Advanced Test Reactor Emergency Firewater Injection System Replacement Project  

Science Conference Proceedings (OSTI)

In accordance with the requirements of U.S. Department of Energy (DOE) Order 413.3B, “Program and Project Management for the Acquisition of Capital Assets,” safety must be integrated into the design process for new or major modifications to DOE Hazard Category 1, 2, and 3 nuclear facilities. The intended purpose of this requirement involves the handling of hazardous materials, both radiological and chemical, in a way that provides adequate protection to the public, workers, and the environment. Requirements provided in DOE Order 413.3B and DOE Order 420.1B, “Facility Safety,” and the expectations of DOE-STD-1189-2008, “Integration of Safety into the Design Process,” provide for identification of hazards early in the project and use of an integrated team approach to design safety into the facility. This safety design strategy provides the basic safety-in-design principles and concepts that will be used for the Advanced Test Reactor Reliability Sustainment Project. While this project does not introduce new hazards to the ATR, it has the potential for significant impacts to safety-related systems, structures, and components that are credited in the ATR safety basis and are being replaced. Thus the project has been determined to meet the definition of a major modification and is being managed accordingly.

Noel Duckwitz

2011-06-01T23:59:59.000Z

102

Spray tip penetration and cone angles for coal-water slurry using a modified medium-speed diesel engine injection system  

Science Conference Proceedings (OSTI)

Experiments have been completed to characterize coal-water slurry sprays from a modified positive displacement fuel injection system of a medium-speed diesel engine. The injection system includes an injection jerk pump driven by an electric motor, a specially designed diaphragm to separate the abrasive coal from the pump, and a single-hole fuel nozzle. The sprays were injected into a pressurized chamber equipped with windows. High speed movies, instantaneous fuel line pressures and needle lifts were obtained. For injection pressures of order 30 MPa, the sprays were similar for coal-water slurry, diesel fuel and water. The time until the center core of the spray broke-up (break-up time) was determined from both the movies and from a correlations using the fuel line pressures. Results from these two independent procedures were in good agreement. For the base case conditions, the break-up time was 0.58 and 0.50 ms for coal-water slurry and diesel fuel, respectively. The break-up times increased with increasing nozzle orifice size and with decreasing chamber density. The break-up time was not a function of coal loading for coal loadings up to 53%. Cone angles of the sprays were dependent on the operating conditions and fluid, as well as on the time and location of the measurement. For the cases studied, the time-averaged cone angles ranged between 10.2 and 17.0{degree}.

Caton, J.a.; Seshadri, A.K.; Kihm, K.D. [Texas A and M Univ., College Station, TX (United States). Dept. of Mechanical Engineering

1992-12-31T23:59:59.000Z

103

Development of a direct-injected natural gas engine system for heavy-duty vehicles: Final report phase 1  

DOE Green Energy (OSTI)

The transportation sector accounts for approximately 65% of US petroleum consumption. Consumption for light-duty vehicles has stabilized in the last 10--15 years; however, consumption in the heavy-duty sector has continued to increase. For various reasons, the US must reduce its dependence on petroleum. One significant way is to substitute alternative fuels (natural gas, propane, alcohols, and others) in place of petroleum fuels in heavy-duty applications. Most alternative fuels have the additional benefit of reduced exhaust emissions relative to petroleum fuels, thus providing a cleaner environment. The best long-term technology for heavy-duty alternative fuel engines is the 4-stroke cycle, direct injected (DI) engine using a single fuel. This DI, single fuel approach maximizes the substitution of alternative fuel for diesel and retains the thermal efficiency and power density of the diesel engine. This report summarizes the results of the first year (Phase 1) of this contract. Phase 1 focused on developing a 4-stroke cycle, DI single fuel, alternative fuel technology that will duplicate or exceed diesel power density and thermal efficiency, while having exhaust emissions equal to or less than the diesel. Although the work is currently on a 3500 Series DING engine, the work is viewed as a basic technology development that can be applied to any engine. Phase 1 concentrated on DING engine component durability, exhaust emissions, and fuel handling system durability. Task 1 focused on identifying primary areas (e.g., ignition assist and gas injector systems) for future durability testing. In Task 2, eight mode-cycle-averaged NO{sub x} emissions were reduced from 11.8 gm/hp-hr (baseline conditions) to 2.5 gm/hp-hr (modified conditions) on a 3501 DING engine. In Task 3, a state-of-the-art fuel handling system was identified.

NONE

2000-03-02T23:59:59.000Z

104

State and National Energy and Environmental Risk Analysis Systems for underground injection control. Quarterly report, April 1, 1994--July 31, 1994  

SciTech Connect

This task involves developing a preliminary national energy and environmental risk analysis system (EERAS). An analytical methodology for nationwise estimation of potential for USDW contamination from underground injection and the current and future resource potential associated with these areas of concern will be developed.

Not Available

1994-07-15T23:59:59.000Z

105

Proof of concept testing of an integrated dry injection system for SO{sub 2}/NO{sub x} control. Final report  

Science Conference Proceedings (OSTI)

The integrated Dry Injection Process (IDIP) consists of combustion modification using low NO{sub x} burners to reduce NO{sub x} emissions, dry injection of hydrated line at economizer temperatures for primary capture of SO{sub 2}, dry injection of a commercial grade sodium bicarbonate at the air heater exit for additional SO{sub 2} and NO{sub x} removal, and humidification for precipitator conditioning. IDIP offers the potential for simultaneously achieving 90% SO{sub 2} removal, and 65% NO{sub x} removal from a high sulfur flue gas. The process is well suited for new or retrofit applications since it can be incorporated within existing economizer and downstream ductwork. Subscale tests were performed in order to identify the best calcium and sodium sorbents. These tests involved the injection of calcium hydroxide and sodium sorbents at various points of the flue gas system downstream of a 0.25 MM BTU/hr. coal fired combustor, and the gas residence times, cooling rates and temperatures were comparable to those found for full-scale utility boilers. These tests verified that a high surface area hydrated lime provides maximum sorbent utilization and identified an alcohol-water hydrated lime as yielding the highest surface area and the best SO{sub 2} removal capability. The tests also identified sodium bicarbonate to be somewhat more effective than sodium sesquicarbonate for SO{sub 2} removal. The proof of concept demonstration was conducted on the large combustor at the Riley Stoker Research Facility in Worcester, MA. When economically compared to conventional limestone slurry scrubbing on a 300 MW plant, the dry injection process shows lower capital cost but higher operating cost. Hydrated lime injection can be less costly than limestone scrubbing when two or more of the following conditions exist: plant is small (less than 100MW); yearly operating hours are small (less than 3000); and the remaining plant lifetime is small (less than 10 years).

Helfritch, D.J.; Bortz, S.J. [Research-Cottrell, Inc., Somerville, NJ (United States); Beittel, R. [Riley Stoker Corp., Worcester, MA (United States)

1994-03-01T23:59:59.000Z

106

Evaluation of C-14 as a natural tracer for injected fluids at theAidlin sector of The Geysers geothermal system through modeling ofmineral-water-gas Reactions  

DOE Green Energy (OSTI)

A reactive-transport model for 14C was developed to test its applicability to the Aidlin geothermal system. Using TOUGHREACT, we developed a 1-D grid to evaluate the effects of water injection and subsequent water-rock-gas interaction on the compositions of the produced fluids. A dual-permeability model of the fracture-matrix system was used to describe reaction-transport processes in which the permeability of the fractures is many orders of magnitude higher than that of the rock matrix. The geochemical system included the principal minerals (K-feldspar, plagioclase, calcite, silica polymorphs) of the metagraywackes that comprise the geothermal reservoir rocks. Initial simulation results predict that the gas-phase CO2 in the reservoir will become more enriched in 14C as air-equilibrated injectate water (with a modern carbon signature) is incorporated into the system, and that these changes will precede accompanying decreases in reservoir temperature. The effects of injection on 14C in the rock matrix will be lessened somewhat because of the dissolution of matrix calcite with ''dead'' carbon.

Dobson, Patrick; Sonnenthal, Eric; Lewicki, Jennifer; Kennedy, Mack

2006-06-01T23:59:59.000Z

107

Prediction of energy change due to hot carrier injection in nano-structured CMOS system: Perspective of an envelope detector  

Science Conference Proceedings (OSTI)

Due to aggressive scaling of CMOS technology, many time-variant issues are catastrophic to MOSFET reliability. Hot carrier injection (HCI) is one of these reliability issues and is a limiting factor for n-MOSFET performance. The HCI aging effect causes ... Keywords: CMOS reliability, Gain change, Radio frequency, n-MOSFET aging

Nissar Mohammad Karim, Norhayati Soin, Sadia Manzoor, F. Y. Soon, M. Mounir

2013-11-01T23:59:59.000Z

108

An environmental analysis of injection molding  

E-Print Network (OSTI)

This thesis investigates injection molding from an environmental standpoint, yielding a system-level environmental analysis of the process. There are three main objectives: analyze the energy consumption trends in injection ...

Thiriez, Alexandre

2006-01-01T23:59:59.000Z

109

Synchronized droplet size measurements of intermittent coal-water slurry diesel sprays from an electronically-controlled accumulator fuel injection system  

E-Print Network (OSTI)

Experiments have been completed to characterize atomization of intermittent coal-water slurry sprays from an electronically controlled accumulator fuel injection system of a diesel fuel engine. A synchronized laser diffraction particle analyzer technique was used to measure the spray tip Sauter mean diameters (SMD). The Rosin-Rammler two parameter model was assumed for the droplet distribution. The measurements were made at the spray tip where laser obscuration was low and the chance of multiscattering bias was minimal. Coal-water slurry fuel with 50% coal loading by mass containing 5gm volume mean diameter coal particles was used. Injection pressures were ranged from 28 to II 0 MPa. Three different nozzle orifice diameters, 0.2, 0.4, and 0.6 mm, four axial measurement locations from 60 to 120 mm downstream of the nozzle tip were studied. Measurements were made for both pressurized (2.07 MPa, 300 psig) and unpressurized (ambient, 0 gage) chamber conditions. The spray tip SMD showed an increase with chamber gas density, and with axial measurement location, and showed a decrease with increasing injection pressure. The effect of nozzle orifice diameter on spray tip SMDs of completely developed sprays for such high pressure injections was found to be negligible. A regression equation for CWS-50 spray tip SMDs was determined as SMD = 0.279-P(inj).?702 r(amb) 2?85 x .521 where Pinj is the injection pressure in Mpa, r(amb) is the ambient density in kg/m3, and x is the axial measurement location downstream of the nozzle tip in mm. The equation shows very good agreement with the measured SMD data by having a Pearson correlation coefficient of 0.97. The results were also compared with previous SMD regression equations that were originally obtained for diesel fuel sprays.

Terracina, Dwayne Paul

1993-01-01T23:59:59.000Z

110

Alkali injection system with controlled CO.sub.2 /O.sub.2 ratios for combustion of coal  

DOE Patents (OSTI)

A high temperature combustion process for an organic fuel containing sulfur n which the nitrogen of air is replaced by carbon dioxide for combination with oxygen with the ratio of CO.sub.2 /O.sub.2 being controlled to generate combustion temperatures above 2000 K. for a gas-gas reaction with SO.sub.2 and an alkali metal compound to produce a sulfate and in which a portion of the carbon-dioxide rich gas is recycled for mixing with oxygen and/or for injection as a cooling gas upstream from heating exchangers to limit fouling of the exchangers, with the remaining carbon-dioxide rich gas being available as a source of CO.sub.2 for oil recovery and other purposes.

Berry, Gregory F. (Naperville, IL)

1988-01-01T23:59:59.000Z

111

Alkali injection system with controlled CO/sub 2//O/sub 2/ ratios for combustion of coal  

DOE Patents (OSTI)

A high temperature combustion process for an organic fuel containing sulfur in which the nitrogen of air is replaced by carbon dioxide for combination with oxygen with the ratio of CO/sub 2//O/sub 2/ being controlled to generate combustion temperatures above 2000/sup 0/K for a gas-gas reaction with SO/sub 2/ and an alkali metal compound to produce a sulfate and in which a portion of the carbon-dioxide rich gas is recycled for mixing with oxygen and/or for injection as a cooling gas upstream from heating exchangers to limit fouling of the exchangers, with the remaining carbon-dioxide rich gas being available as a source of CO/sub 2/ for oil recovery and other purposes. Several advantages are associated with the invention. First, by using a low CO/sub 2//O/sub 2/ ratio, higher flame temperatures can be achieved, thereby substantially promoting the gas-gas reaction between alkali atoms and sulfur gases. Second, by providing a means for injecting additional CO/sub 2/ at various locations removed from the combustion zone, the heat transfer rate and cooling of the alkali sulfates can be tightly controlled without suffering either the loss in efficiency inherent in conventional gas recycle techniques or the added cost associated with the larger mass throughput rate and heat transfer surface area. Third, there is the ability to use the concept in retrofit applications by tailoring the CO/sub 2/ quantity recycled to match the heat utilization performance previously achieved using air as the oxidizing medium. Fourth, a natural reduction in nitrous oxides is achieved by eliminating the reaction of oxygen with the nitrogen in the oxidizer.

Berry, G.F.

1986-11-21T23:59:59.000Z

112

Corrective Action Investigation Plan for Corrective Action Unit 219: Septic Systems and Injection Wells, Nevada Test Site, Nevada, Rev. No.: 0  

Science Conference Proceedings (OSTI)

The Corrective Action Investigation Plan for Corrective Action Unit 219, Septic Systems and Injection Wells, has been developed in accordance with the ''Federal Facility Agreement and Consent Order'' (1996) that was agreed to by the State of Nevada, the U.S. Department of Energy, and the U.S. Department of Defense. The purpose of the investigation is to ensure that adequate data are collected to provide sufficient and reliable information to identify, evaluate, and select technically viable corrective actions. Corrective Action Unit 219 is located in Areas 3, 16, and 23 of the Nevada Test Site, which is 65 miles northwest of Las Vegas, Nevada. Corrective Action Unit 219 is comprised of the six Corrective Action Sites (CASs) listed below: (1) 03-11-01, Steam Pipes and Asbestos Tiles; (2) 16-04-01, Septic Tanks (3); (3) 16-04-02, Distribution Box; (4) 16-04-03, Sewer Pipes; (5) 23-20-01, DNA Motor Pool Sewage and Waste System; and (6) 23-20-02, Injection Well. These sites are being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives. Additional information will be obtained by conducting a corrective action investigation prior to evaluating corrective action alternatives and selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible evaluation of viable corrective action alternatives that will be presented in the Corrective Action Decision Document.

David A. Strand

2005-01-01T23:59:59.000Z

113

Scaleup tests and supporting research for the development of duct injection technology. Topical report No. 2, Task 3.1: Evaluation of system performance, Duct Injection Test Facility, Muskingum River Power Plant, Beverly, Ohio  

Science Conference Proceedings (OSTI)

This Topical Report No. 2 is an interim report on the Duct Injection Test Facility being operated for the Department of Energy at Beverly, Ohio. Either dry calcium hydroxide or an aqueous slurry of calcium hydroxide (prepared by slaking quicklime) is injected into a slipstream of flue gas to achieve partial removal of SO{sub 2} from a coal-burning power station. Water injected with the slurry or injected separately from the dry sorbents cools the flue gas and increases the water vapor content of the gas. The addition of water, either in the slurry or in a separate spray, makes the extent of reaction between the sorbent and the SO{sub 2} more complete; the presumption is that water is effective in the liquid state, when it is able to wet the sorbent particles physically, and not especially effective in the vapor state. An electrostatic precipitator collects the combination of suspended solids (fly ash from the boiler and sorbent from the duct injection process). All of the operations are being carried out on the scale of approximately 50,000 acfm of flue gas.

Felix, L.G.; Dismukes, E.B.; Gooch, J.P. [Southern Research Inst., Birmingham, AL (United States); Klett, M.G.; Demian, A.G. [Gilbert/Commonwealth, Inc., Reading, PA (United States)

1992-04-20T23:59:59.000Z

114

Operational experience during the LHC injection tests  

E-Print Network (OSTI)

Following the LHC injection tests of 2008. two injection tests took place in October and November 2009 as preparation for the LHC restart on November 20, 2009. During these injection tests beam was injected through the TI 2 transfer line into sector 23 of ring 1 and through TI 8 into the sectors 78, 67 and 56 of ring 2. The beam time was dedicated to injection steering, optics measurements and debugging of all the systems involved. Because many potential problems were sorted out in advance, these tests contributed to the rapid progress after the restart. This paper describes the experiences and issues encountered during these tests as well as related measurement results.

Fuchsberger, K; Arduini, G; Assmann, R; Bailey, R; Bruning, O; Goddard, B; Kain, V; Lamont, M; MacPherson, A; Meddahi, M; Papotti, G; Pojer, M; Ponce, L; Redaelli, S; Solfaroli Camillocci, M; Venturini Delsolaro, W; Wenninger, J

2010-01-01T23:59:59.000Z

115

Injection of Short-Lived Radionuclides into the Early Solar System from a Faint Supernova with Mixing-Fallback  

E-Print Network (OSTI)

Several short-lived radionuclides (SLRs) were present in the early solar system, some of which should have formed just prior to or soon after the solar system formation. Stellar nucleosynthesis has been proposed as the mechanism for production of SLRs in the solar system, but no appropriate stellar source has been found to explain the abundances of all solar system SLRs. In this study, we propose a faint supernova with mixing and fallback as a stellar source of SLRs with mean lives of <5 Myr (26Al, 41Ca, 53Mn, and 60Fe) in the solar system. In such a supernova, the inner region of the exploding star experiences mixing, a small fraction of mixed materials is ejected, and the rest undergoes fallback onto the core. The modeled SLR abundances agree well with their solar system abundances if mixing-fallback occurs within the C/O-burning layer. In some cases, the initial solar system abundances of the SLRs can be reproduced within a factor of 2. The dilution factor of supernova ejecta to the solar system materials is ~10E-4 and the time interval between the supernova explosion and the formation of oldest solid materials in the solar system is ~1 Myr. If the dilution occurred due to spherically symmetric expansion, a faint supernova should have occurred nearby the solar system forming region in a star cluster.

A. Takigawa; J. Miki; S. Tachibana; G. R. Huss; N. Tominaga; H. Umeda; K. Nomoto

2008-08-11T23:59:59.000Z

116

Internal Technical Report, Management Plan for Fluid Supply and Injection System for the Raft River 5 MW(e) Pilot Power Plant  

DOE Green Energy (OSTI)

This report details a plan for developing a fluid supply system for the First 5 MW(e) Pilot Power Plant at Raft River. The pilot plant has been specifically designed to use the medium-temperature geothermal water so common throughout the West. EG and G Idaho, Inc., the Department of Energy Raft River Rural Electric Co-op, the US Geological Survey (USGS) and the State of Idaho have worked together to develop a facility that will use an organic liquid as the working fluid. Four wells have been drilled in the Raft River Valley, about ten miles South of Malta, in southern Idaho. The completed well system will consist of seven wells: two conventional injection wells, three production wells, and a standby reserve well of each type. The additional three wells are to be drilled in FY-1978, in order to complete a coordinated test program before the First Pilot Power Plant is ready for operation. The system has been designed to meet the test-loop pilot plant's basic requirement: a 2450 gpm supply of geothermal fluid, at a nominal temperature of 290 F and with salinity of less than 5000 ppm. Injection of cooled geothermal fluid into the Raft River reservoir will also require a network of monitor wells. The Idaho Department of Water Resources (IDWR), USGS, EG and G Idaho, and the Department of Energy will jointly select sites for two 1500-foot and five 500-foot monitoring wells. This plan considers the work required to complete construction of the fluid supply system and obtain a preliminary check of its performance capability; the plan will discuss project management, costs, schedules, drilling, testing, environmental monitoring, and safety.

None

1978-01-09T23:59:59.000Z

117

System to inject steam and produce oil from the same wellbore through downhole valve switching. Final report  

SciTech Connect

Through direct contacts with many California Operators, the potential market for this technology and hardware was more closely defined. The largest market might be for re-entry into existing but shut-in wells, equipped with 7{double_prime}OD cemented casings, for which a suitable configuration was designed. For field-testing any prototype Downhole equipment, however, Operators and Service Companies prefer to start with a new well, for better control of the well characteristics. In the relatively shallow reservoirs where Steam injection is currently used with success, the additional drilling cost, in soft formations, is sufficiently small that this became the main design case. Substantial savings were obtained by reducing the number of Downhole valves from two to one and by replacing the twin hydraulically-controlled ball or flapper-type valves with a single sliding sleeve valve, operated by wireline. Laboratory tests conducted at UC-Berkeley confirmed the satisfactory operation of this type of valve with wet steam over extended periods. Low reservoir pressures dictated the use of artificial lift methods, with rod pumps considered the most economical. The availability of live steam downhole at all times is, however, a major advantage which led to the selection of a combined method of artificial lift: (1) steam-lift of the produced fluids up to the kick-off point of the medium curvature drainholes, (2) dumping of the produced fluids into a vertical separator/sump below the kick-off points, (3) vertical rod pumping of the liquid phases from the downhole separator/sump to the surface through a dedicated production tubing.

Not Available

1994-10-01T23:59:59.000Z

118

Abstract--Distribution factors play a key role in many system security analysis and market applications. The injection shift  

E-Print Network (OSTI)

1 Abstract-- Distribution factors play a key role in many system security analysis and market of the other distribution factors. The line outage distribution factors (LODFs) may be computed using the ISFs distribution factors, line outage distribution factors, multiple-line outages, system security. I. INTRODUCTION

119

Slit injection device  

DOE Patents (OSTI)

A laser cavity electron beam injection device provided with a single elongated slit window for passing a suitably shaped electron beam and means for varying the current density of the injected electron beam.

Alger, Terry W. (Livermore, CA); Schlitt, Leland G. (Livermore, CA); Bradley, Laird P. (Livermore, CA)

1976-06-15T23:59:59.000Z

120

Rich catalytic injection  

SciTech Connect

A gas turbine engine includes a compressor, a rich catalytic injector, a combustor, and a turbine. The rich catalytic injector includes a rich catalytic device, a mixing zone, and an injection assembly. The injection assembly provides an interface between the mixing zone and the combustor. The injection assembly can inject diffusion fuel into the combustor, provides flame aerodynamic stabilization in the combustor, and may include an ignition device.

Veninger, Albert (Coventry, CT)

2008-12-30T23:59:59.000Z

Note: This page contains sample records for the topic "injection dsi systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Geothermal injection monitoring project  

DOE Green Energy (OSTI)

Background information is provided on the geothermal brine injection problem and each of the project tasks is outlined in detail. These tasks are: evaluation of methods of monitoring the movement of injected fluid, preparation for an eventual field experiment, and a review of groundwater regulations and injection programs. (MHR)

Younker, L.

1981-04-01T23:59:59.000Z

122

Program on Technology Innovation: Mitigation of Flow-Accelerated Corrosion by Titanium Injection in PWR Secondary Systems  

Science Conference Proceedings (OSTI)

This report summarizes the results of a study to determine the potential of titanium-containing compounds for mitigating the flow-accelerated corrosion (FAC) of carbon steel piping in the feedwater train of PWRs. Currently, plants of all types are investigating methods to reduce the severity of FAC in vulnerable systems. Titanium dioxide (TiO2) has been a promising additive under Canadian deuterium/uranium (CANDU) primary conditions, and Ti has been used routinely to mitigate localized corrosion in steam...

2010-03-30T23:59:59.000Z

123

Diesel engine emissions reduction by multiple injections having increasing pressure  

DOE Patents (OSTI)

Multiple fuel charges are injected into a diesel engine combustion chamber during a combustion cycle, and each charge after the first has successively greater injection pressure (a higher injection rate) than the prior charge. This injection scheme results in reduced emissions, particularly particulate emissions, and can be implemented by modifying existing injection system hardware. Further enhancements in emissions reduction and engine performance can be obtained by using known measures in conjunction with the invention, such as Exhaust Gas Recirculation (EGR).

Reitz, Rolf D. (Madison, WI); Thiel, Matthew P. (Madison, WI)

2003-01-01T23:59:59.000Z

124

Modular ultrahigh vacuum-compatible gas-injection system with an adjustable gas flow for focused particle beam-induced deposition  

Science Conference Proceedings (OSTI)

A gas-injection system (GIS) heats up a powdery substance and transports the resulting gas through a capillary into a vacuum chamber. Such a system can be used to guide a (metal)organic precursor gas very close to the focal area of an electron or ion beam, where a permanent deposit is created and adheres to the substrate. This process is known as focused particle beam-induced deposition. The authors present design principles and give construction details of a GIS suitable for ultrahigh vacuum usage. The GIS is composed of several self-contained components which can be customized rather independently. It allows for a continuously adjustable gas-flow rate. The GIS was attached to a standard scanning electron microscope (JEOL 6100) and tested with the tungsten precursor W(CO){sub 6}. The analysis of the deposits by means of atomic force microscopy and energy dispersive x-ray spectroscopy provides clear evidence that excellent gas-flow-rate stability and ensuing growth rate and metal-content reproducibility are experienced.

Klingenberger, D.; Huth, M. [Physikalisches Institut, Goethe University, 60438 Frankfurt am Main (Germany)

2009-09-15T23:59:59.000Z

125

Use of data obtained from core tests in the design and operation of spent brine injection wells in geopressured or geothermal systems  

DOE Green Energy (OSTI)

The effects of formation characteristics on injection well performance are reviewed. Use of data acquired from cores taken from injection horizons to predict injectivity is described. And methods for utilizing data from bench scale testing of brine and core samples to optimize injection well design are presented. Currently available methods and equipment provide data which enable the optimum design of injection wells through analysis of cores taken from injection zones. These methods also provide a means of identifying and correcting well injection problems. Methods described in this report are: bulk density measurement; porosity measurement; pore size distribution analysis; permeability measurement; formation grain size distribution analysis; core description (lithology) and composition; amount, type and distribution of clays and shales; connate water analysis; consolidatability of friable reservoir rocks; grain and pore characterization by scanning electron microscopy; grain and pore characterization by thin section analysis; permeability damage and enhancement tests; distribution of water-borne particles in porous media; and reservoir matrix acidizing effectiveness. The precise methods of obtaining this information are described, and their use in the engineering of injection wells is illustrated by examples, where applicable. (MHR)

Jorda, R.M.

1980-03-01T23:59:59.000Z

126

Underground Injection Control (Louisiana)  

Energy.gov (U.S. Department of Energy (DOE))

The Injection and Mining Division (IMD) has the responsibility of implementing two major federal environmental programs which were statutorily charged to the Office of Conservation: the Underground...

127

Alkaline sorbent injection for mercury control  

DOE Patents (OSTI)

A mercury removal system for removing mercury from combustion flue gases is provided in which alkaline sorbents at generally extremely low stoichiometric molar ratios of alkaline earth or an alkali metal to sulfur of less than 1.0 are injected into a power plant system at one or more locations to remove at least between about 40% and 60% of the mercury content from combustion flue gases. Small amounts of alkaline sorbents are injected into the flue gas stream at a relatively low rate. A particulate filter is used to remove mercury-containing particles downstream of each injection point used in the power plant system.

Madden, Deborah A. (Boardman, OH); Holmes, Michael J. (Washington Township, Stark County, OH)

2003-01-01T23:59:59.000Z

128

Alkaline sorbent injection for mercury control  

DOE Patents (OSTI)

A mercury removal system for removing mercury from combustion flue gases is provided in which alkaline sorbents at generally extremely low stoichiometric molar ratios of alkaline earth or an alkali metal to sulfur of less than 1.0 are injected into a power plant system at one or more locations to remove at least between about 40% and 60% of the mercury content from combustion flue gases. Small amounts of alkaline sorbents are injected into the flue gas stream at a relatively low rate. A particulate filter is used to remove mercury-containing particles downstream of each injection point used in the power plant system.

Madden, Deborah A. (Boardman, OH); Holmes, Michael J. (Washington Township, Stark County, OH)

2002-01-01T23:59:59.000Z

129

Changes related to "Denmark Solar Industry DSI" | Open Energy...  

Open Energy Info (EERE)

Login | Sign Up Wiki Browse Latinoamrica Buildings Clean Energy Economy Coordinated Low Emissions Assistance Network Geothermal Incentives and Policies International Clean Energy...

130

Yet Another Fault Injection Technique : by Forward Body Biasing Injection  

E-Print Network (OSTI)

expensive fault injection tech- niques, like clock or voltage glitches, are well taken into accountYet Another Fault Injection Technique : by Forward Body Biasing Injection K. TOBICH1,2, P. MAURINE1 Injection, Electromag- netic Attacks, RSA, Chinese Remainder Theorem 1 Introduction Fault injection

131

Numerical simulation study of silica and calcite dissolution around a geothermal well by injecting high pH solutions with chelating agent.  

E-Print Network (OSTI)

transport modeling of injection well scaling and acidizingto a field geothermal injection well system, to investigateespecially near the injection well. CALCITE DISSOLUTION

Xu, Tianfu

2009-01-01T23:59:59.000Z

132

Direct liquid injection of liquid petroleum gas  

SciTech Connect

A fuel injector and injection system for injecting liquified petroleum gas (LPG) into at least one air/fuel mixing chamber from a storage means that stores pressurized LPG in its liquid state. The fuel injector (including a body), adapted to receive pressurized LPG from the storage means and for selectively delivering the LPG to the air/fuel mixing chamber in its liquified state. The system including means for correcting the injector activation signal for pressure and density variations in the fuel.

Lewis, D.J.; Phipps, J.R.

1984-02-14T23:59:59.000Z

133

A study of steam injection in fractured media  

SciTech Connect

Steam injection is the most widely used thermal recovery technique for unfractured reservoirs containing heavy oil. There have been numerous studies on theoretical and experimental aspects of steam injection for such systems. Fractured reservoirs contain a large fraction of the world supply of oil, and field tests indicate that steam injection is feasible for such reservoirs. Unfortunately there has been little laboratory work done on steam injection in such systems. The experimental system in this work was designed to understand the mechanisms involved in the transfer of fluids and heat between matrix rocks and fractures under steam injection.

Dindoruk, M.D.S.; Aziz, K.; Brigham, W.; Castanier, L.

1996-02-01T23:59:59.000Z

134

Corrective Action Decision Document/Closure Report for Corrective Action Unit 219: Septic Systems and Injection Wells, Nevada Test Site, Nevada, Rev. No.: 0  

SciTech Connect

This Corrective Action Decision Document/Closure Report has been prepared for Corrective Action Unit (CAU) 219, Septic Systems and Injection Wells, in Areas 3, 16, and 23 of the Nevada Test Site, Nevada, in accordance with the ''Federal Facility Agreement and Consent Order'' (1996). Corrective Action Unit 219 is comprised of the following corrective action sites (CASs): (1) 03-11-01, Steam Pipes and Asbestos Tiles; (2) 16-04-01, Septic Tanks (3); (3) 16-04-02, Distribution Box; (4) 16-04-03, Sewer Pipes; (5) 23-20-01, DNA Motor Pool Sewage and Waste System; and (6) 23-20-02, Injection Well. The purpose of this Corrective Action Decision Document/Closure Report is to provide justification and documentation supporting the recommendation for closure of CAU 219 with no further corrective action beyond the application of a use restriction at CASs 16-04-01, 16-04-02, and 16-04-03. To achieve this, corrective action investigation (CAI) activities were performed from June 20 through October 12, 2005, as set forth in the CAU 219 Corrective Action Investigation Plan and Record of Technical Change No. 1. A best management practice was implemented at CASs 16-04-01, 16-04-02, and 16-04-03, and corrective action was performed at CAS 23-20-01 between January and April 2006. In addition, a use restriction will be applied to CASs 16-04-01, 16-04-02, and 16-04-03 to provide additional protection to Nevada Test Site personnel. The purpose of the CAI was to fulfill the following data needs as defined during the data quality objective (DQO) process: (1) Determine whether contaminants of concern (COCs) are present. (2) If COCs are present, determine their nature and extent. (3) Provide sufficient information and data to complete appropriate corrective actions. The CAU 219 dataset from the investigation results was evaluated based on the data quality indicator parameters. This evaluation demonstrated the quality and acceptability of the dataset for use in fulfilling the DQO data needs. Analytes detected during the CAI were evaluated against final action levels (FALs) established in this document. A Tier 2 evaluation was conducted, and a FAL of 185,000 micrograms per kilogram was calculated for chlordane at CASs 16-04-01, 16-04-02, and 16-04-03 based on an occasional use area exposure scenario. This evaluation of chlordane based on the Tier 2 FAL determined that no FALs were exceeded. Therefore, the DQO data needs were met, and it was determined that no corrective action (based on risk to human receptors) is necessary for the site. The following contaminants were determined to be present at concentrations exceeding their corresponding FALs: (1) The surface soil surrounding the main concrete pad at CAS 23-20-01 contained Aroclor-1254, Aroclor-1260, and chlordane above the FALs. This soil, along with the COCs, was subsequently removed at CAS 23-20-01. (2) The sludge in the concrete box of the catch basin at the large concrete pad at CAS 23-20-01 contained lead and benzo(a)pyrene above the FALs. This contamination was limited to the sludge in the concrete box of the catch basin and did not migrate to the subsurface features beneath it. The contaminated and the concrete box of the catch basin were subsequently recovered at CAS 23-20-01.

David Strand

2006-05-01T23:59:59.000Z

135

BOOSTER EXTRACTION, BOOSTER-TO-STORAGE RING TRANSPORT AND STORAGE RING INJECTION FOR THE ALS  

E-Print Network (OSTI)

Storage Ring Injection for the ALS M.S. Zisman March 1988Ring Injection for the ALS Michael S. Zisman Exploratoryon the design of the ALS injection system is presented. The

Zisman, M.S.

2010-01-01T23:59:59.000Z

136

Effects of sorbent injection for sulfur dioxide removal on particulate control systems for coal-fired boilers. Final report, October 1984-October 1987  

Science Conference Proceedings (OSTI)

This report describes studies undertaken to quantify the effects of dry SO2 sorbent injection on electrostatic precipitator (ESP) operation with a coal-burning utility boiler. The specific operation of interest was EPA's limestone injection, multistage burners (LIMB) process. The combination of spent sorbent and fly ash has a higher resistivity, a higher mass concentration, and a finer particle-size distribution than the ash alone; all of these factors diminish the effectiveness of ESP. Also investigated was chemical conditioning to reduce the resistivity problem, the only one of three concerns stemming from sorbent injection that can be readily mitigated. Other topics studied were: the recycle, disposal, and utilization of waste-ash/sorbent mixtures; the selection and modification of sorbents to improve SO2 capture in the furnace; and the reactivation of spent sorbent by humidification to achieve supplemental post-furnace capture of SO2.

Gooch, J.P.; DuBard, J.L.; Faulkner, M.G.; Marchant, G.H.; Dahlin, R.S.

1988-11-01T23:59:59.000Z

137

carbon sequestration via direct injection  

NLE Websites -- All DOE Office Websites (Extended Search)

SEQUESTRATION VIA DIRECT INJECTION SEQUESTRATION VIA DIRECT INJECTION Howard J. Herzog, Ken Caldeira, and Eric Adams INTRODUCTION The build-up of carbon dioxide (CO 2 ) and other greenhouse gases in the Earth's atmosphere has caused concern about possible global climate change. As a result, international negotiations have produced the Framework Convention on Climate Change (FCCC), completed during the 1992 Earth Summit in Rio de Janeiro. The treaty, which the United States has ratified, calls for the "stabilization of greenhouse gas concentrations in the atmosphere at a level that would prevent dangerous anthropogenic interference with the climate system." The primary greenhouse gas is CO 2 , which is estimated to contribute to over two-thirds of any climate change. The primary source of CO

138

Studies of injection into naturally fractured reservoirs  

DOE Green Energy (OSTI)

A semi-analytical model for studies of cold water injection into naturally fractured reservoirs has been developed. The model can be used to design the flow rates and location of injection wells in such systems. The results obtained using the model show that initially the cold water will move very rapidly through the fracture system away from the well. Later on, conductive heat transfer from the rock matrix blocks will retard the advancement of the cold water front, and eventually uniform energy sweep conditions will prevail. Where uniform energy sweep conditions are reached the cold waer movement away from the injection well will be identical to that in a porous medium; consequently maximum energy recovery from the rock matrix will be attained. The time of uniform energy sweep and the radial distance from the injection well where it occurs are greatly dependent upon the fracture spacing, but independent of the fracture aperture.

Boedvarsson, G.S.; Lai, C.H.

1982-10-01T23:59:59.000Z

139

Smart Materials for Fuel Injection Actuation  

DOE Green Energy (OSTI)

The demands of stringent emissions and a robust engine dynamic torque response characteristic require innovative, accurate and repeatable control of the fuel injection event. Recent advances in piezo-material actuators have warranted the pursuit of its application to advanced heavy-duty truck fuel injection systems. This presentation will report on design and testing of an advanced electronic unit injector for the Detroit Diesel Series 60 truck engine.

Hakim, Nabil

2000-08-20T23:59:59.000Z

140

Fluidized bed injection assembly for coal gasification  

DOE Patents (OSTI)

A coaxial feed system for fluidized bed coal gasification processes including an inner tube for injecting particulate combustibles into a transport gas, an inner annulus about the inner tube for injecting an oxidizing gas, and an outer annulus about the inner annulus for transporting a fluidizing and cooling gas. The combustibles and oxidizing gas are discharged vertically upward directly into the combustion jet, and the fluidizing and cooling gas is discharged in a downward radial direction into the bed below the combustion jet.

Cherish, Peter (Bethel Park, PA); Salvador, Louis A. (Hempfield Township, Westmoreland County, PA)

1981-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "injection dsi systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Near-surface groundwater responses to injection of geothermal wastes  

DOE Green Energy (OSTI)

Experiences with injecting geothermal fluids have identified technical problems associated with geothermal waste disposal. This report assesses the feasibility of injection as an alternative for geothermal wastewater disposal and analyzes hydrologic controls governing the upward migration of injected fluids. Injection experiences at several geothermal developments are presented, including: Raft River, Salton Sea, East Mesa, Otake and Hatchobaru in Japan, and Ahuachapan in El Salvador. Hydrogeologic and design/operational factors affecting the success of an injection program are identified. Hydrogeologic factors include subsidence, near-surface effects of injected fluids, and seismicity. Design/operational factors include hydrodynamic breakthrough, condition of the injection system and reservoir maintenance. Existing and potential effects of production/injection on these factors are assessed.

Arnold, S.C.

1984-06-01T23:59:59.000Z

142

Optimization of Injection Scheduling in  

E-Print Network (OSTI)

- of wells,and (2) allocating a total speci6cd injection rate among chosen injectors. The alloca- tion is defined as the fieldwide break- through lindex, B. Injection is optimized by choosing injection wells questions: (1) Which wells should be made injectors? (2) How should the total nquired injection rate

Stanford University

143

Fuel injection device and method  

DOE Patents (OSTI)

A fuel injection system and method provide for shaping a combustion plume within a combustion chamber to effectively recirculate hot combustion gases for stable combustion conditions while providing symmetrical combustion conditions. Char and molten slag are passed to the outer boundary layer to complete combustion of char while permitting initial substoichiometric combustion in a reductive atmosphere for reducing discharge of nitrogen oxides. Shaping of the plume is accomplished by an axially adjustable pintle which permits apportionment of driving pressure between elements which contribute tangential and those which contribute radial directional components to oxidant flow entering the combustion chamber.

Carlson, Larry W. (Oswego, IL)

1986-01-01T23:59:59.000Z

144

Fuel injection device and method  

DOE Patents (OSTI)

A fuel injection system and method provide for shaping a combustion plume within a combustion chamber to effectively recirculate hot combustion gases for stable combustion conditions while providing symmetrical combustion conditions. Char and molten slag are passed to the outer boundary layer to complete combustion of char while permitting initial substoichiometric combustion in a reductive atmosphere for reducing discharge of nitrogen oxides. Shaping of the plume is accomplished by an axially adjustable pintle which permits apportionment of driving pressure between elements which contribute tangential and those which contribute radial directional components to oxidant flow entering the combustion chamber.

Carlson, L.W.

1983-12-21T23:59:59.000Z

145

Neutral beam injection in 2XIIB  

SciTech Connect

Integrated into the operation of the 2XIIB controlled fusion experiment is a 600-A, 20-keV neutral injection system: the highest neutral-beam current capacity of any existing fusion machine. This paper outlines the requirements of the injection system and the design features to which they led. Both mechanical and electrical aspects are discussed. Also included is a brief description of some operational aspects of the system and some of the things we have learned along the way, as well as a short history of the most significant developments. (auth)

Hibbs, S.M.

1975-11-01T23:59:59.000Z

146

Injection of Electrons and Holes into Nanostructures  

NLE Websites -- All DOE Office Websites (Extended Search)

Injection of Electrons and Holes into Nanostructures Injection of Electrons and Holes into Nanostructures This program targets fundamental understanding of nanoscale charge transfer processes. The proposed work draws on the strengths of the Brookhaven Chemistry Department in the areas of electron transfer experiment and theory, and extends the area of inquiry to nanoscale processes. Electron/hole injection into a wire, a nanocrystal, a nanotube or other nanostructure in solution may be brought about by light absorption, by an electron pulse (pulse radiolysis, LEAF), by a chemical reagent, or through an electrode. These processes are being studied by transient methods by following conductivity, current, but most generally, spectroscopic changes in the solutions to determine the dynamics of charge injection. The observed transient spectra can also provide values for electron-transfer coupling elements and energetics. Theoretical/computational studies can help in materials design and in the interpretation of the experimental results. The experimental systems being examined include molecular wires and metal nanoclusters.

147

Numerical simulation of water injection into vapor-dominated reservoirs  

DOE Green Energy (OSTI)

Water injection into vapor-dominated reservoirs is a means of condensate disposal, as well as a reservoir management tool for enhancing energy recovery and reservoir life. We review different approaches to modeling the complex fluid and heat flow processes during injection into vapor-dominated systems. Vapor pressure lowering, grid orientation effects, and physical dispersion of injection plumes from reservoir heterogeneity are important considerations for a realistic modeling of injection effects. An example of detailed three-dimensional modeling of injection experiments at The Geysers is given.

Pruess, K.

1995-01-01T23:59:59.000Z

148

Gaseous Fuel Injection Modeling using a Gaseous Sphere Injection Methodology  

DOE Green Energy (OSTI)

The growing interest in gaseous fuels (hydrogen and natural gas) for internal combustion engines calls for the development of computer models for simulation of gaseous fuel injection, air entrainment and the ensuing combustion. This paper introduces a new method for modeling the injection and air entrainment processes for gaseous fuels. The model uses a gaseous sphere injection methodology, similar to liquid droplet in injection techniques used for liquid fuel injection. In this paper, the model concept is introduced and model results are compared with correctly- and under-expanded experimental data.

Hessel, R P; Aceves, S M; Flowers, D L

2006-03-06T23:59:59.000Z

149

-Injection Technology -Geothermal Reservoir Engineering  

E-Print Network (OSTI)

the injection well to^ production wells along high conductivity fractures. A powerful method for investigat- ing fields typically choose a configuration for injection wells after a number of development wells have of cooler injected fluids at producing wells. The goal of the current #12;- 10 - work is to provide

Stanford University

150

Injection in basin and range-type reservoirs: the Raft River experience  

DOE Green Energy (OSTI)

Injection testing at the Raft River KGRA has yielded some interesting results which can be useful in planning injection systems in Basin and Range type reservoirs. Because of inhomogeneities and possible fracturing in basin fill sediment, rapid pressure response to injection has been observed in one shallow monitor well, but not others. In some monitor wells in the injection field, pressure drops are observed during injection suggesting plastic deformation of the sediments. Seismicity, however, has not accompanied these observed water level changes.

Petty, S.; Spencer, S.

1981-01-01T23:59:59.000Z

151

Underground Injection Control Regulations (Kansas)  

Energy.gov (U.S. Department of Energy (DOE))

This article prohibits injection of hazardous or radioactive wastes into or above an underground source of drinking water, establishes permit conditions and states regulations for design,...

152

Underground Injection Control Rule (Vermont)  

Energy.gov (U.S. Department of Energy (DOE))

This rule regulates injection wells, including wells used by generators of hazardous or radioactive wastes, disposal wells within an underground source of drinking water, recovery of geothermal...

153

Injectivity Test | Open Energy Information  

Open Energy Info (EERE)

Injectivity Test Injectivity Test Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: Injectivity Test Details Activities (7) Areas (6) Regions (0) NEPA(1) Exploration Technique Information Exploration Group: Downhole Techniques Exploration Sub Group: Well Testing Techniques Parent Exploration Technique: Well Testing Techniques Information Provided by Technique Lithology: Stratigraphic/Structural: Hydrological: Permeability of the well Thermal: Dictionary.png Injectivity Test: A well testing technique conducted upon completion of a well. Water is pumped into the well at a constant rate until a stable pressure is reached then the pump is turned off and the rate at which pressure decreases is measured. The pressure measurements are graphed and well permeability can

154

Energy recovery by water injection  

DOE Green Energy (OSTI)

Several analytical and numerical studies that address injection and thermal breakthrough in fractured geothermal reservoirs are described. The results show that excellent thermal sweeps can be achieved in fractured reservoirs, and that premature cold water breakthrough can be avoided if the injection wells are appropriately located.

Witherspoon, P.A.; Bodvarsson, G.S.; Pruess, K.; Tsang, C.F.

1982-07-01T23:59:59.000Z

155

Review of Alternate Hydrazine Injection Data: South Texas Project Power Station -- Unit 1  

Science Conference Proceedings (OSTI)

This report reviews South Texas Project Unit 1 chemistry data collected before, during, and after alternate hydrazine injections in 1999. Normally, hydrazine is injected into the condensate system just after the condensate polishers, but during alternate hydrazine injection periods, hydrazine was fed into the feedwater system just after the last feedwater heater. The main objective of these injections was to reduce feedwater iron concentrations; additionally, their effect on several chemistry parameters ...

2001-06-11T23:59:59.000Z

156

PROGRESS WITH NSLS-II INJECTION STRAIGHT SECTION DESIGN  

SciTech Connect

The NSLS-II injection straight section (SR) consists of pulsed and DC bumps, septa system, beam trajectory correction and diagnostics systems. In this paper we discuss overall injection straight layout, preliminary element designs, specifications for the pulsed and DC magnets and their power supplies, vacuum devices and chambers and diagnostics devices. Prior to selecting the current 'conventional' design of the injection straight section we analyzed an option of injection via pulsed multipole pioneered at PF-AR. We found that this promising approach was not suited to the NSLS-II storage ring optics, since it would require a impractically compact arrangement of the injection straight section components and a complex modification of the transport line optics due to the strong focusing of the injected beam passing off the pulsed multipole axis. In addition, the requirement for a small injection transient of the stored beam orbit severely constrains the vertical alignment tolerance of the pulsed multipole. The design of the NSLS-II injection straight section is now completed with exception of transition chamber details, which will be adjusted to accommodate the actual layouts of the pulsed magnets.

Shaftan, T.; Blednykh, A.; Casey, B.; Dalesio, B.; Faussete, R.; Ferreira, M.; Fliller, R.; Ganetis, G.; Heese, R.; Hseuh, H.-C.; Job, P.K.; Johnson, E.; Kosciuk, B.; Kowalski, S.; Padrazo, D.; Parker, B.; Pinayev, I.; Sharma, S.; Singh, O.; Spataro, C.

2011-03-28T23:59:59.000Z

157

Injection, injectivity and injectability in geothermal operations: problems and possible solutions. Phase I. Definition of the problems  

DOE Green Energy (OSTI)

The following topics are covered: thermodynamic instability of brine, injectivity loss during regular production and injection operations, injectivity loss caused by measures other than regular operations, heat mining and associated reservoir problems in reinjection, pressure maintenance through imported make-up water, suggested solutions to injection problems, and suggested solutions to injection problems: remedial and stimulation measures. (MHR)

Vetter, O.J.; Crichlow, H.B.

1979-02-14T23:59:59.000Z

158

NEUTRAL-BEAM INJECTION  

SciTech Connect

The emphasis in the preceding chapters has been on magnetic confinement of high temperature plasmas. The question of production and heating of such plasmas has been dealt with relatively more briefly. It should not be inferred, however, that these matters must therefore be either trivial or unimportant. A review of the history reveals that in the early days all these aspects of the controlled fusion problem were considered to be on a par, and were tackled simultaneously and with equal vigor. Only the confinement problem turned out to be much more complex than initially anticipated, and richer in challenge to the plasma physicist than the questions of plasma production and heating. On the other hand, the properties of high-temperature plasmas and plasma confinement can only be studied experimentally after the problems of production and of heating to adequate temperatures are solved. It is the purpose of this and the next chapter to supplement the preceding discussions with more detail on two important subjects: neutral-beam injection and radio-frequency heating. These are the major contenders for heating in present and future tokamak and mirror fusion experiments, and even in several proposed reactors. For neutral beams we emphasize here the technology involved, which has undergone a rather remarkable development. The physics of particle and energy deposition in the plasma, and the discussion of the resulting effects on the confined plasma, have been included in previous chapters, and some experimental results are quoted there. Other heating processes of relevance to fusion are mentioned elsewhere in this book, in connection with the experiments where they are used: i.e. ohmic heating, adiabatic compression heating, and alpha-particle heating in Chapter 3 by H.P. Furth; more ohmic heating in Chapter 7, and shock-implosion heating, laser heating, and relativistic-electron beam heating in Chapter 8, both by W. E. Quinn. These methods are relatively straightforward in their physics and their technology, or in any case they are considered to be adequately covered by these other authors.

Kunkel, W.B.

1980-06-01T23:59:59.000Z

159

PLT neutral injection ignitron accelerating supply  

SciTech Connect

A phase-controlled rectifier was designed for the accelerating supply on the PLT Neutral Beam Injection system at PPPL. The rectifier must furnish 70 amperes at up to 50 KV for 300 milliseconds, with a duty cycle of up to 10 percent. Protection of the injectors requires the supply to withstand repeated crowbarring. The rectifying element selected to satisfy these requirements was a commercially-available ignitron, installed in a supporting frame and using firing circuits and controls designed by PPPL. (auth)

Ashcroft, D.L.; Murray, J.G.; Newman, R.A.; Peterson, F.L.

1975-11-01T23:59:59.000Z

160

Economics of dry FGD by sorbent injection  

SciTech Connect

Increasingly stringent pollution control requirements for new power plants have nearly doubled the cost of producing electricity. The capital, operating and maintenance costs of wet flue gas desulfurization (FGD) systems are major, and considerable interest is currently being given to less expensive dry systems. One attractive alternative to wet scrubbing for FGD is to inject a dry, powdered reagent into the duct work between a coal-fired boiler and a FF (baghouse). The reagent (and fly ash) are collected on the fabric surface where the SO/sub 2//reagent contact occurs. The technical aspects of SO/sub 2/ removal using nahcolite and trona as sorbents have been investigated at laboratory-scale, demonstrated at full-scale, and are reported on briefly. These results indicate that injection of sodium based reagents is technically an attractive alternative to the many steps and processes involved in wet scrubbing. This paper summarizes a project to examine the economics of nahcolite/trona and furnace limestone injection FGD and compare them to those of the more advanced spray dryer FGD systems. Uncertainties in material handling, pulverization, and waste disposal were investigated and designs were produced as a basis for cost estimating.

Naulty, D.J.; Hooper, R.; Keeth, R.J.; McDowell, D.A.; Muzio, L.J.; Scheck, R.W.

1983-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "injection dsi systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Injection nozzle for a turbomachine  

Science Conference Proceedings (OSTI)

A turbomachine includes a compressor, a combustor operatively connected to the compressor, an end cover mounted to the combustor, and an injection nozzle assembly operatively connected to the combustor. The injection nozzle assembly includes a first end portion that extends to a second end portion, and a plurality of tube elements provided at the second end portion. Each of the plurality of tube elements defining a fluid passage includes a body having a first end section that extends to a second end section. The second end section projects beyond the second end portion of the injection nozzle assembly.

Uhm, Jong Ho; Johnson, Thomas Edward; Kim, Kwanwoo

2012-09-11T23:59:59.000Z

162

-OGP 04 (1) -Predicting Injectivity Decline  

E-Print Network (OSTI)

- OGP 04 (1) - Predicting Injectivity Decline in Water Injection Wells by Upscaling On-Site Core, resulting in injectivity decline of injection wells. Particles such as biomass, corrosion products, silt on permeability. These data were then processed, upscaled to model injection wells and, finally, history matched

Abu-Khamsin, Sidqi

163

Underground Injection Control (West Virginia) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Injection Control (West Virginia) Injection Control (West Virginia) Underground Injection Control (West Virginia) < Back Eligibility Utility Fed. Government Commercial Agricultural Investor-Owned Utility State/Provincial Govt Industrial Construction Municipal/Public Utility Local Government Residential Installer/Contractor Rural Electric Cooperative Tribal Government Low-Income Residential Schools Retail Supplier Institutional Multi-Family Residential Systems Integrator Fuel Distributor Nonprofit General Public/Consumer Transportation Program Info State West Virginia Program Type Siting and Permitting Provider Department of Environmental Protection This rule set forth criteria and standards for the requirements which apply to the State Underground Injection Control Program (U.I.C.). The UIC permit program regulates underground injections by 5 classes of wells. All owners

164

NETL: Mercury Emissions Control Technologies - Sorbent Injection for Small  

NLE Websites -- All DOE Office Websites (Extended Search)

Sorbent Injection for Small ESP Mercury Control in Low Sulfur Eastern Bituminous Coal Flue Gas Sorbent Injection for Small ESP Mercury Control in Low Sulfur Eastern Bituminous Coal Flue Gas URS Group and their test team will evaluate sorbent injection for mercury control on sites with low-SCA ESPs, burning low sulfur Eastern bituminous coals. Full-scale tests will be performed at Plant Yates Units 1 and 2 to evaluate sorbent injection performance across a cold-side ESP/wet FGD and a cold-side ESP with a dual NH3/SO3 flue gas conditioning system, respectively. Short-term parametric tests on Units 1 and 2 will provide data on the effect of sorbent injection rate on mercury removal and ash/FGD byproduct composition. Tests on Unit 2 will also evaluate the effect of dual-flue gas conditioning on sorbent injection performance. Results from a one-month injection test on Unit 1 will provide insight to the long-term performance and variability of this process as well as any effects on plant operations. The goals of the long-term testing are to obtain sufficient operational data on removal efficiency over time, effects on the ESP and balance of plant equipment, and on injection equipment operation to prove process viability.

165

Adaptive engine injection for emissions reduction  

DOE Patents (OSTI)

NOx and soot emissions from internal combustion engines, and in particular compression ignition (diesel) engines, are reduced by varying fuel injection timing, fuel injection pressure, and injected fuel volume between low and greater engine loads. At low loads, fuel is injected during one or more low-pressure injections occurring at low injection pressures between the start of the intake stroke and approximately 40 degrees before top dead center during the compression stroke. At higher loads, similar injections are used early in each combustion cycle, in addition to later injections which preferably occur between about 90 degrees before top dead center during the compression stroke, and about 90 degrees after top dead center during the expansion stroke (and which most preferably begin at or closely adjacent the end of the compression stroke). These later injections have higher injection pressure, and also lower injected fuel volume, than the earlier injections.

Reitz, Rolf D. (Madison, WI): Sun, Yong (Madison, WI)

2008-12-16T23:59:59.000Z

166

A Case History of Injection Through 1991 at Dixie Valley, Nevada | Open  

Open Energy Info (EERE)

Case History of Injection Through 1991 at Dixie Valley, Nevada Case History of Injection Through 1991 at Dixie Valley, Nevada Jump to: navigation, search OpenEI Reference LibraryAdd to library Journal Article: A Case History of Injection Through 1991 at Dixie Valley, Nevada Abstract The Dixie Valley injection system has been operational for 3 1/4 years and disperses injectate into the reservoir through three distinct geological environments. Short term step-rate injection tests underestimated the long term injectivity of some of the injectors requiring additional injectors to be drilled. Liberal use of surface discharge over three years allowed orderly development of an eight-well injection system that provides pressure support for nine production wells but has not yet resulted in any cooling problems. Tracer testing identified a single flow path while long

167

Examinatal Study on Common Rail Diesel Engine for Multi-injection Strategies  

Science Conference Proceedings (OSTI)

Based on diesel engine equipped with common rail, the multi-injection strategies common rail diesel engine test bed is established with NI test system. In this test bed, the influences of optimized multi-injection strategies to diesel engine performances ... Keywords: common rail, diesel engine, multi-injection, emission

An Shijie; Chang Hanbao; Xu Hongjun

2010-05-01T23:59:59.000Z

168

Engine with hydraulic fuel injection and ABS circuit using a single high pressure pump  

DOE Patents (OSTI)

An engine system comprises a hydraulically actuated fuel injection system and an ABS circuit connected via a fluid flow passage that provides hydraulic fluid to both the fuel injection system and to the ABS circuit. The hydraulically actuated system includes a high pressure pump. The fluid control passage is in fluid communication with an outlet from the high pressure pump.

Bartley, Bradley E. (Manito, IL); Blass, James R. (Bloomington, IL); Gibson, Dennis H. (Chillicothe, IL)

2001-01-01T23:59:59.000Z

169

Injecting Carbon Dioxide into Unconventional Storage Reservoirs...  

NLE Websites -- All DOE Office Websites (Extended Search)

will also be investigated with a targeted CO 2 injection test into a depleted shale gas well. Different reservoir models will be used before, during, and after injection...

170

Massachusetts Natural Gas Underground Storage Injections All...  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Injections All Operators (Million Cubic Feet) Massachusetts Natural Gas Underground Storage Injections All Operators (Million Cubic Feet) Decade Year-0 Year-1...

171

Interpretation of self-potential measurements during injection tests at  

Open Energy Info (EERE)

self-potential measurements during injection tests at self-potential measurements during injection tests at Raft River, Idaho. Final report Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Report: Interpretation of self-potential measurements during injection tests at Raft River, Idaho. Final report Details Activities (1) Areas (1) Regions (0) Abstract: Self-potential measurements before and during injection tests at Raft River KGRA, Idaho indicate a small negative change. The magnitude of the change (5 to 10 mV) is near the noise level (5 mV) but they extend over a fairly broad area. The presence of a cathodic protection system clouds the issue of the validity of the changes, however the form of the observed changes cannot be explained by any simple change in the current strength of the protection system. Furthermore, similar changes are observed for two

172

Staged direct injection diesel engine  

DOE Patents (OSTI)

A diesel engine having staged injection for using lower cetane number fuels than No. 2 diesel fuel. The engine includes a main fuel injector and a pilot fuel injector. Pilot and main fuel may be the same fuel. The pilot injector injects from five to fifteen percent of the total fuel at timings from 20.degree. to 180.degree. BTDC depending upon the quantity of pilot fuel injected, the fuel cetane number and speed and load. The pilot fuel injector is directed toward the centerline of the diesel cylinder and at an angle toward the top of the piston, avoiding the walls of the cylinder. Stratification of the early injected pilot fuel is needed to reduce the fuel-air mixing rate, prevent loss of pilot fuel to quench zones, and keep the fuel-air mixture from becoming too fuel lean to become effective. In one embodiment, the pilot fuel injector includes a single hole for injection of the fuel and is directed at approximately 48.degree. below the head of the cylinder.

Baker, Quentin A. (San Antonio, TX)

1985-01-01T23:59:59.000Z

173

PEP-II injection timing and controls  

SciTech Connect

Hardware has been built and software written and incorporated in the existing SLC accelerator control system to control injection of beam pulses from the accelerator into the PEP-II storage rings currently under construction. Hardware includes a CAMAC module to delay the machine timing fiducial in order that a beam pulse extracted from a damping ring will be injected into a selected group of four 476 MHz buckets in a PEP-II ring. Further timing control is accomplished by shifting the phase of the bunches stored in the damping rings before extraction while leaving the phase of the PEP-II stored beam unchanged. The software which drives timing devices on a pulse-to-pulse basis relies on a dedicated communication link on which one scheduling microprocessor broadcasts a 128-bit message to all distributed control microprocessors at 360 Hz. PEP-II injection will be driven by the scheduling microprocessor according to lists specifying bucket numbers in arbitrary order, and according to scheduling constraints maximizing the useful beam delivered to the SLC collider currently in operation. These lists will be generated by a microprocessor monitoring the current stored per bucket in each of the PEP-II rings.

Bharadwaj, V.; Browne, M.; Crane, M.; Gromme, T.; Himel, T.; Ross, M.; Stanek, M. [Stanford Linear Accelerator Center, Menlo Park, CA (United States); Ronan, M. [Lawrence Berkeley National Lab., CA (United States)

1997-07-01T23:59:59.000Z

174

Stokes injected Raman capillary waveguide amplifier  

DOE Patents (OSTI)

A device for producing stimulated Raman scattering of CO.sub.2 laser radiation by rotational states in a diatomic molecular gas utilizing a Stokes injection signal. The system utilizes a cryogenically cooled waveguide for extending focal interaction length. The waveguide, in conjunction with the Stokes injection signal, reduces required power density of the CO.sub.2 radiation below the breakdown threshold for the diatomic molecular gas. A Fresnel rhomb is employed to circularly polarize the Stokes injection signal and CO.sub.2 laser radiation in opposite circular directions. The device can be employed either as a regenerative oscillator utilizing optical cavity mirrors or as a single pass amplifier. Additionally, a plurality of Raman gain cells can be staged to increase output power magnitude. Also, in the regenerative oscillator embodiment, the Raman gain cell cavity length and CO.sub.2 cavity length can be matched to provide synchronism between mode locked CO.sub.2 pulses and pulses produced within the Raman gain cell.

Kurnit, Norman A. (Santa Fe, NM)

1980-01-01T23:59:59.000Z

175

Improved Water Flooding through Injection Brine Modification  

Science Conference Proceedings (OSTI)

Crude oil/brine/rock interactions can lead to large variations in the displacement efficiency of waterflooding, by far the most widely applied method of improved oil recovery. Laboratory waterflood tests show that injection of dilute brine can increase oil recovery. Numerous fields in the Powder River basin have been waterflooded using low salinity brine (about 500 ppm) from the Madison limestone or Fox Hills sandstone. Although many uncertainties arise in the interpretation and comparison of field production data, injection of low salinity brine appears to give higher recovery compared to brine of moderate salinity (about 7,000 ppm). Laboratory studies of the effect of brine composition on oil recovery cover a wide range of rock types and crude oils. Oil recovery increases using low salinity brine as the injection water ranged from a low of no notable increase to as much as 37.0% depending on the system being studied. Recovery increases using low salinity brine after establishing residual oil saturation (tertiary mode) ranged from no significant increase to 6.0%. Tests with two sets of reservoir cores and crude oil indicated slight improvement in recovery for low salinity brine. Crude oil type and rock type (particularly the presence and distribution of kaolinite) both play a dominant role in the effect that brine composition has on waterflood oil recovery.

Robertson, Eric Partridge; Thomas, Charles Phillip; Morrow, Norman; (U of Wyoming)

2003-01-01T23:59:59.000Z

176

Geology of Injection Well 46A-19RD in the Coso Enhanced Geothermal...  

Open Energy Info (EERE)

Geology of Injection Well 46A-19RD in the Coso Enhanced Geothermal Systems Experiment Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Conference Proceedings: Geology...

177

Process planning for rapid manufacturing of plastic injection mold for short run production.  

E-Print Network (OSTI)

??This thesis presents a process planning methodology for a rapid injection mold tool manufacturing system that involves additive and subtractive techniques, whereby slabs are sequentially… (more)

Karthikeyan, Rajesh Kumar

2010-01-01T23:59:59.000Z

178

Injection with seawater: problems in the operation of a seawater treatment plant  

Science Conference Proceedings (OSTI)

Reservoir pressure elevation by means of water injection in the production formation is a technique that improves production efficiency. In offshore activities, seawater is available for injection, but it has a high level of solids in suspension and also ions and dissolved gases that may cause problems in the water injection system. Therefore, a seawater treatment plant is necessary for preparation of the injection water. The treatment system has the following components for physical treatment: colander, which prevents the intake of large objects to the system; filters, which include flocculation for coagulation means for the removal of microscopic particles that can pass through the colander; deaerator; and system controls.

Garbis, S.J.

1982-05-01T23:59:59.000Z

179

Injection and energy recovery in fractured geothermal reservoirs  

DOE Green Energy (OSTI)

Numerical studies of the effects of injection on the behavior of production wells completed in fractured two-phase geothermal reservoirs are presented. In these studies the multiple-interacting-continua (MINC) method is employed for the modeling of idealized fractured reservoirs. Simulations are carried out for a five-spot well pattern with various well spacings, fracture spacings, and injection fractions. The production rates from the wells are calculated using a deliverability model. The results of the studies show that injection into two-phase fractured reservoirs increases flow rates and decreases enthalpies of producing wells. These two effects offset each other so that injection tends to have small effects on the usable energy output of production wells in the short term. However, if a sufficiently large fraction of the produced fluids is injected, the fracture system may become liquid-filled and an increased steam rate is obtained. Our studies show that injection greatly increases the long-term energy output from wells, as it helps extract heat from the resrvoir rocks. If a high fraction of the produced fluids is injected, the ultimate energy recovery will increase manyfold.

Bodvarsson, G.S.; Pruess, K.; O'Sullivan, M.J.

1983-01-01T23:59:59.000Z

180

Boosting software fault injection for dependability analysis of real-time embedded applications  

Science Conference Proceedings (OSTI)

The design of complex embedded systems deployed in safety-critical or mission-critical applications mandates the availability of methods to validate the system dependability across the whole design flow. In this article we introduce a fault injection ... Keywords: Embedded systems, fault injection, real-time applications

Gianpiero Cabodi; Marco Murciano; Massimo Violante

2010-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "injection dsi systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

-Injection Technology -Geothermal Reservoir Engineering  

E-Print Network (OSTI)

.A. Hsieh 1e$ Pressure Buildup Monitoring of the Krafla Geothermal Field, . . . . . . . . 1'1 Xceland - 0 Initial Chemical and Reservoir Conditions at Lo6 Azufres Wellhead Power Plant Startup - P. Kruger, LSGP-TR-92 - Injection Technology - Geothermal Reservoir Engineering Research at Stanford Principal

Stanford University

182

Underground Injection Control Fee Schedule (West Virginia) | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Injection Control Fee Schedule (West Virginia) Injection Control Fee Schedule (West Virginia) Underground Injection Control Fee Schedule (West Virginia) < Back Eligibility Utility Fed. Government Commercial Agricultural Investor-Owned Utility State/Provincial Govt Industrial Construction Municipal/Public Utility Local Government Residential Installer/Contractor Rural Electric Cooperative Tribal Government Low-Income Residential Schools Retail Supplier Institutional Multi-Family Residential Systems Integrator Fuel Distributor Nonprofit General Public/Consumer Transportation Program Info State West Virginia Program Type Fees Provider Department of Environmental Protection This rule establishes schedules of permit fees for state under-ground injection control permits issued by the Chief of the Office of Water Resources. This rule applies to any person who is required to apply for and

183

PREFAIL: a programmable tool for multiple-failure injection  

Science Conference Proceedings (OSTI)

As hardware failures are no longer rare in the era of cloud computing, cloud software systems must "prevail" against multiple, diverse failures that are likely to occur. Testing software against multiple failures poses the problem of combinatorial explosion ... Keywords: distributed systems, fault injection, testing

Pallavi Joshi; Haryadi S. Gunawi; Koushik Sen

2011-10-01T23:59:59.000Z

184

Radial lean direct injection burner  

Science Conference Proceedings (OSTI)

A burner for use in a gas turbine engine includes a burner tube having an inlet end and an outlet end; a plurality of air passages extending axially in the burner tube configured to convey air flows from the inlet end to the outlet end; a plurality of fuel passages extending axially along the burner tube and spaced around the plurality of air passage configured to convey fuel from the inlet end to the outlet end; and a radial air swirler provided at the outlet end configured to direct the air flows radially toward the outlet end and impart swirl to the air flows. The radial air swirler includes a plurality of vanes to direct and swirl the air flows and an end plate. The end plate includes a plurality of fuel injection holes to inject the fuel radially into the swirling air flows. A method of mixing air and fuel in a burner of a gas turbine is also provided. The burner includes a burner tube including an inlet end, an outlet end, a plurality of axial air passages, and a plurality of axial fuel passages. The method includes introducing an air flow into the air passages at the inlet end; introducing a fuel into fuel passages; swirling the air flow at the outlet end; and radially injecting the fuel into the swirling air flow.

Khan, Abdul Rafey; Kraemer, Gilbert Otto; Stevenson, Christian Xavier

2012-09-04T23:59:59.000Z

185

Analysis of PWR RCS Injection Strategy During Severe Accident  

Science Conference Proceedings (OSTI)

Reactor coolant system (RCS) injection is an important strategy for severe accident management of a pressurized water reactor (PWR) system. Maanshan is a typical Westinghouse PWR nuclear power plant (NPP) with large, dry containment. The severe accident management guideline (SAMG) of Maanshan NPP is developed based on the Westinghouse Owners Group (WOG) SAMG.The purpose of this work is to analyze the RCS injection strategy of PWR system in an overheated core condition. Power is assumed recovered as the vessel water level drops to the bottom of active fuel. The Modular Accident Analysis Program version 4.0.4 (MAAP4) code is chosen as a tool for analysis. A postulated station blackout sequence for Maanshan NPP is cited as a reference case for this analysis. The hot leg creep rupture occurs during the mitigation action with immediate injection after power recovery according to WOG SAMG, which is not desired. This phenomenon is not considered while developing the WOG SAMG. Two other RCS injection methods are analyzed by using MAAP4. The RCS injection strategy is modified in the Maanshan SAMG. These results can be applied for typical PWR NPPs.

Wang, S.-J. [Institute of Nuclear Energy Research, Taiwan (China); Chiang, K.-S. [Institute of Nuclear Energy Research, Taiwan (China); Chiang, S.-C. [Taiwan Power Company, Taiwan (China)

2004-05-15T23:59:59.000Z

186

The energy injection and losses in the Monte Carlo simulations of a diffusive shock  

E-Print Network (OSTI)

Although diffusive shock acceleration (DSA) could be simulated by some well-established models, the assumption of the injection rate from the thermal particles to the superthermal population is still a contentious problem. But in the self-consistent Monte Carlo simulations, because of the prescribed scattering law instead of the assumption of the injected function, hence particle injection rate is intrinsically defined by the prescribed scattering law. We expect to examine the correlation of the energy injection with the prescribed multiple scattering angular distributions. According to the Rankine-Hugoniot conditions, the energy injection and the losses in the simulation system can directly decide the shock energy spectrum slope. By the simulations performed with multiple scattering law in the dynamical Monte Carlo model, the energy injection and energy loss functions are obtained. As results, the case applying anisotropic scattering law produce a small energy injection and large energy losses leading to a s...

Wang, Xin

2011-01-01T23:59:59.000Z

187

Experience with Zinc Injection in European PWRs  

Science Conference Proceedings (OSTI)

Zinc injection is an effective technique for lowering shutdown dose rates in pressurized water reactors (PWRs). This report compiles information about zinc injection experience at Siemens PWRs and compares the results with the use of zinc injection at U.S. PWRs. The plant data confirm that even low concentrations of zinc in the reactor water can indeed lower shutdown dose rates, but plants should make a concerted effort to inject zinc on a continuous basis to achieve the best results.

2002-11-01T23:59:59.000Z

188

Injectivity Testing for Vapour Dominated Feed Zones  

DOE Green Energy (OSTI)

Wells with vapor dominated feed zones yield abnormal pressure data. This is caused by the condensation of vapor during water injection. A revised injectivity test procedure currently applied by PNOC at the Leyte Geothermal Power Project has improved the injectivity test results.

Clotworthy, A.W.; Hingoyon, C.S.

1995-01-01T23:59:59.000Z

189

Ejector device for direct injection fuel jet  

SciTech Connect

Disclosed is a device for increasing entrainment and mixing in an air/fuel zone of a direct fuel injection system. The device comprises an ejector nozzle in the form of an inverted funnel whose central axis is aligned along the central axis of a fuel injector jet and whose narrow end is placed just above the jet outlet. It is found that effective ejector performance is achieved when the ejector geometry is adjusted such that it comprises a funnel whose interior surface diverges about 7.degree. to about 9.degree. away from the funnel central axis, wherein the funnel inlet diameter is about 2 to about 3 times the diameter of the injected fuel plume as the fuel plume reaches the ejector inlet, and wherein the funnel length equal to about 1 to about 4 times the ejector inlet diameter. Moreover, the ejector is most effectively disposed at a separation distance away from the fuel jet equal to about 1 to about 2 time the ejector inlet diameter.

Upatnieks, Ansis (Livermore, CA)

2006-05-30T23:59:59.000Z

190

INJECTIVE COGENERATORS AMONG OPERATOR BIMODULES  

E-Print Network (OSTI)

Abstract. Given C ?-algebras A and B acting cyclically on Hilbert spaces H and K, respectively, we characterize completely isometric A, B-bimodule maps from B(K, H) into operator A, B-bimodules. We determine cogenerators in some classes of operator bimodules. For an injective cogenerator X in a suitable category of operator A, B-bimodules we show: if A, regarded as a C ?-subalgebra of A?(X) (adjointable left multipliers on X), is equal to its relative double commutant in A?(X), then A must be a W ?-algebra. 1.

Bojan Magajna

2005-01-01T23:59:59.000Z

191

Gasification system  

DOE Patents (OSTI)

A method and system for injecting coal and process fluids into a fluidized bed gasification reactor. Three concentric tubes extend vertically upward into the fluidized bed. Coal particulates in a transport gas are injected through an inner tube, and an oxygen rich mixture of oxygen and steam are injected through an inner annulus about the inner tube. A gaseous medium relatively lean in oxygen content, such as steam, is injected through an annulus surrounding the inner annulus.

Haldipur, Gaurang B. (Hempfield, PA); Anderson, Richard G. (Penn Hills, PA); Cherish, Peter (Bethel Park, PA)

1983-01-01T23:59:59.000Z

192

Gasification system  

DOE Patents (OSTI)

A method and system for injecting coal and process fluids into a fluidized bed gasification reactor. Three concentric tubes extend vertically upward into the fluidized bed. Coal particulates in a transport gas are injected through an inner tube, and an oxygen rich mixture of oxygen and steam are injected through an inner annulus about the inner tube. A gaseous medium relatively lean in oxygen content, such as steam, is injected through an annulus surrounding the inner annulus.

Haldipur, Gaurang B. (Hempfield, PA); Anderson, Richard G. (Penn Hills, PA); Cherish, Peter (Bethel Park, PA)

1985-01-01T23:59:59.000Z

193

The Impact of Injection on Seismicity at The Geyses, CaliforniaGeothermal Field  

DOE Green Energy (OSTI)

Water injection into geothermal systems has often become arequired strategy to extended and sustain production of geothermalresources. To reduce a trend of declining pressures and increasingnon-condensable gas concentrations in steam produced from The Geysers,operators have been injecting steam condensate, local rain and streamwaters, and most recently treated wastewater piped to the field fromneighboring communities. If geothermal energy is to provide a significantincrease in energy in the United States (US Department of Energy (DOE)goal is 40,000 megawatts by 2040), injection must play a larger role inthe overall strategy, i.e., enhanced geothermal systems, (EGS). Presentedin this paper are the results of monitoring microseismicity during anincrease in injection at The Geysers field in California using data froma high-density digital microearthquake array. Although seismicity hasincreased due to increased injection it has been found to be somewhatpredicable, thus implying that intelligent injection control may be ableto control large increases in seismicity.

Majer, Ernest L.; Peterson, John E.

2006-09-25T23:59:59.000Z

194

DUS II SOIL GAS SAMPLING AND AIR INJECTION TEST RESULTS  

Science Conference Proceedings (OSTI)

Soil vapor extraction (SVE) and air injection well testing was performed at the Dynamic Underground Stripping (DUS) site located near the M-Area Settling Basin (referred to as DUS II in this report). The objective of this testing was to determine the effectiveness of continued operation of these systems. Steam injection ended on September 19, 2009 and since this time the extraction operations have utilized residual heat that is present in the subsurface. The well testing campaign began on June 5, 2012 and was completed on June 25, 2012. Thirty-two (32) SVE wells were purged for 24 hours or longer using the active soil vapor extraction (ASVE) system at the DUS II site. During each test five or more soil gas samples were collected from each well and analyzed for target volatile organic compounds (VOCs). The DUS II site is divided into four parcels (see Figure 1) and soil gas sample results show the majority of residual VOC contamination remains in Parcel 1 with lesser amounts in the other three parcels. Several VOCs, including tetrachloroethylene (PCE) and trichloroethylene (TCE), were detected. PCE was the major VOC with lesser amounts of TCE. Most soil gas concentrations of PCE ranged from 0 to 60 ppmv with one well (VEW-22A) as high as 200 ppmv. Air sparging (AS) generally involves the injection of air into the aquifer through either vertical or horizontal wells. AS is coupled with SVE systems when contaminant recovery is necessary. While traditional air sparging (AS) is not a primary component of the DUS process, following the cessation of steam injection, eight (8) of the sixty-three (63) steam injection wells were used to inject air. These wells were previously used for hydrous pyrolysis oxidation (HPO) as part of the DUS process. Air sparging is different from the HPO operations in that the air was injected at a higher rate (20 to 50 scfm) versus HPO (1 to 2 scfm). . At the DUS II site the air injection wells were tested to determine if air sparging affected VOC soil gas concentrations during ASVE. Five (5) SVE wells that were located closest to the air injection wells were used as monitoring points during the air sparging tests. The air sparging tests lasted 48 hours. Soil gas sample results indicate that sparging did not affect VOC concentrations in four of the five sparging wells, while results from one test did show an increase in soil gas concentrations.

Noonkester, J.; Jackson, D.; Jones, W.; Hyde, W.; Kohn, J.; Walker, R.

2012-09-20T23:59:59.000Z

195

Allergy Injection Policy | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Allergy Injection Policy Allergy Injection Policy Allergy Injection Policy Millions of Americans suffer from perennial and seasonal allergic rhinitis. Allergy immunotherapy is an effective way to reduce or eliminate the symptoms of allergic rhinitis by desensitizing the patient to the allergen(s) by giving escalating doses of an extract via regular injections. Receiving weekly injections at a private physician's office is time consuming, reduces productivity, and can quickly deplete an employee's earned leave. FOH offers the convenience of receiving allergy injections at the OHC as a physician-prescribed service, reducing time away from work for many federal employees. Allergy Injection Policy.pdf More Documents & Publications Physician Treatment Order Handicapped Parking Guidance

196

Method for improving the steam splits in a multiple steam injection process  

SciTech Connect

This patent describes a method for enhancing the uniformity of steam distribution in a multiple steam injection system comprising a steam generator, a steam header, a primary steam line connecting the generator to the header, and secondary steam lines connecting the header to steam injection wells. It comprises: injecting a surfactant into the primary steam line, and mixing the surfactant and steam sufficiently so that the surfactant and the steam enter the header as a foam.

Stowe, G.R. III.

1990-09-04T23:59:59.000Z

197

POROSITY AND PERMEABILITY EVOLUTION ACCOMPANYING HOT FLUID INJECTION  

E-Print Network (OSTI)

. Additionally, funding was provided by the SUPRI-A Industrial Affiliates and the President's Fund of Stanford to the setup used by Koh et al. (1996), but it allows for measurement of porosity by CT scanning. A Blue-M oven to the oven set- point temperature. System pressure is elevated by a back-pressure regulator and injection

198

Boise geothermal injection well: Final environmental assessment  

DOE Green Energy (OSTI)

The City of Boise, Idaho, an Idaho Municipal Corporation, is proposing to construct a well with which to inject spent geothermal water from its hot water heating system back into the geothermal aquifer. Because of a cooperative agreement between the City and the US Department of Energy to design and construct the proposed well, compliance to the National Environmental Policy Act (NEPA) is required. Therefore, this Environmental Assessment (EA) represents the analysis of the proposed project required under NEPA. The intent of this EA is to: (1) briefly describe historical uses of the Boise Geothermal Aquifer; (2) discuss the underlying reason for the proposed action; (3) describe alternatives considered, including the No Action Alternative and the Preferred Alternative; and (4) present potential environmental impacts of the proposed action and the analysis of those impacts as they apply to the respective alternatives.

NONE

1997-12-31T23:59:59.000Z

199

Waste heat steams ahead with injection technology  

Science Conference Proceedings (OSTI)

Owners of Commercial-Industrial-Institutional buildings whose thermal usage is too variable to implement cogeneration are looking to a gasturbine steam-injection technology, called the Cheng Cycle, to reduce their energy costs. The Cheng Cycle uses industrial components-a gas-turbine generating set, a waste-heat recovery steam generator and system controls-in a thermodynamically optimized mode. In the process, steam produced from waste heat can be used for space or process heating or to increase the electrical output of a gas turbine. The process was patented in 1974 by Dr. Dah Yu Cheng, of the University of Santa Clara, Santa Clara, Calif. When a plant's thermal needs fall because of production or temperature changes, unused steam is directed back to the turbine to increase electrical output. As thermal requirements rise, the process is reversed and needed steam is channeled to plant uses.

Shepherd, S.; Koloseus, C.

1985-03-01T23:59:59.000Z

200

Geothermal Injection Technology Program: Annual progress report, Fiscal Year 1986  

DOE Green Energy (OSTI)

This report summarizes the Geothermal Injection Technology Program major activities in fiscal year 1986. The Idaho Engineering Laboratory (INEL) and the University of Utah Research Institute (UURI) have been conducting injection research and testing for this program, which was initiated in 1983. Activities at the INEL, representative element nodeling of fracture systems based on stochastic analysis, dual permeability modeling of flow in a fractured geothermal reservoir, and dual permeability model - laboratory and FRACSL-validation studies, are presented first, followed by the University of Utah Research Institute tracer development - experimental studies, which includes a brief description of activities planned for FY-1987.

Not Available

1987-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "injection dsi systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Functional Significance of Cannabinoid-Mediated, Depolarization-Induced Suppression of Inhibition (DSI) in the Hippocampus  

E-Print Network (OSTI)

by changing the command volt- age from 70 mV (holding potential) to 0 mV for 1.0 s (1.0 s Depol.). Left top

Gorman, Michael

202

Underground Injection Control Permits and Registrations (Texas) |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

You are here You are here Home » Underground Injection Control Permits and Registrations (Texas) Underground Injection Control Permits and Registrations (Texas) < Back Eligibility Utility Agricultural Investor-Owned Utility State/Provincial Govt Industrial Construction Municipal/Public Utility Local Government Installer/Contractor Rural Electric Cooperative Fuel Distributor Savings Category Buying & Making Electricity Program Info State Texas Program Type Environmental Regulations Safety and Operational Guidelines Provider Texas Commission on Environmental Quality Chapter 27 of the Texas Water Code (the Injection Well Act) defines an "injection well" as "an artificial excavation or opening in the ground made by digging, boring, drilling, jetting, driving, or some other

203

LIFAC Sorbent Injection Desulfurization Demonstration Project...  

NLE Websites -- All DOE Office Websites (Extended Search)

of the flue gas in a separate activation reactor, which increases SO 2 removal. An electrostatic precipitator downstream from the point of injection captures the reaction...

204

Geothermal: Sponsored by OSTI -- Injection through fractures  

Office of Scientific and Technical Information (OSTI)

Injection through fractures Geothermal Technologies Legacy Collection HelpFAQ | Site Map | Contact Us | Admin Log On HomeBasic Search About Publications Advanced Search New Hot...

205

NSLS-II INJECTION STRAIGHT DIAGNOSTICS  

Science Conference Proceedings (OSTI)

The ultra-bright light source being developed by the NSLS-II project will utilize top-up injection and fine tuning of the injection process is mandatory. In this paper we present the diagnostics installed in the injection straight. Its use for commissioning and tuning of the injection cycle is also described. The NSLS-II storage ring will utilize a 9.3 meter long injection straight section shown in Fig. 1. Injection will be preformed with two septa (one pulsed, one DC) and four kickers. The stored beam will be shifted towards the pulsed septum up to IS mm and the nominal distance between centers of the injected and the bumped beam is 9.5mm. The NSLS-II beam position monitors will have turn-by-turn and first-turn capabilities and will be used for the commissioning and tuning the injection process. However, there are three additional BPMs and two beam intercepting OTR screens (flags) installed in the injection straight.

Pinayev, I.; Blednykh, A.; Ferreira, M.; Fliller, R.; Kosciuk, B.; Shaftan, T.V.; Wang, G.

2011-03-28T23:59:59.000Z

206

Powder Injection Molding - Available Technologies - PNNL  

Summary. Presented here is a novel and innovative means of powder injection molding (PIM) of reactive refractory metals, such as titanium and its ...

207

Energy-efficient control in injection molding.  

E-Print Network (OSTI)

??xviii, 209 leaves : ill. ; 30 cm HKUST Call Number: Thesis CENG 2008 Yao As an energy-intensive process, in injection molding, energy cost is… (more)

Yao, Ke

2008-01-01T23:59:59.000Z

208

Overview of Recent Developments in Pellet Injection for ITER  

Science Conference Proceedings (OSTI)

Pellet injection is the primary fueling technique planned for core fueling of ITER burning plasmas. Also, the injection of relatively small pellets to purposely trigger rapid small edge localized modes (ELMs) has been proposed as a possible solution to the heat flux damage from larger natural ELMs likely to be an issue on the ITER divertor surfaces. The ITER pellet injection system is designed to inject pellets into the plasma through both inner and outer wall guide tubes. The inner wall guide tubes will provide high throughput pellet fueling while the outerwall guide tubes will be used primarily to trigger ELMs at a high frequency (>15 Hz). The pellet fueling rate ofeach injector is to be up to 120 Pa-m3/s, which will require the formation of solid D-T at a volumetric rate of ~1500 mm3/s. Two injectors are to be provided for ITER at the startup with a provision for up to six injectorsduring the D-T phase. The required throughput of each injector is greater than that of any injector built to date, and a novel twin-screw continuous extrusion system is being developed to meet the challenging design parameters. Status of the development activities will be presented, highlighting recent progress.

Combs, Stephen Kirk [ORNL; Baylor, Larry R [ORNL; Meitner, Steven J [ORNL; Caughman, John B [ORNL; Rasmussen, David A [ORNL; Maruyama, So [ITER Organization, Cadarache, France

2012-01-01T23:59:59.000Z

209

Bibliography: injection technology applicable to geothermal utilization  

DOE Green Energy (OSTI)

This bibliography cites 500 documents that may be helpful in planning, analysis, research, and development of the various aspects of injection technology in geothermal applications. These documents include results from government research; development, demonstration, and commercialization programs; selected references from the literature; symposia; references from various technical societies and installations; reference books; reviews; and other selected material. The cited references are from (1) subject searching, using indexing, storage, and retrieval information data base of the Department of Energy's Technical Information Center's on-line retrieval system, RECON; (2) searches of references from the RECON data base, of work by authors known to be active in the field of geothermal energy research and development; (3) subject and author searches by the computerized data storage and retrieval system of Chemical Abstracts, American Chemical Society, Washington, DC; and (4) selected references from texts and reviews on this subject. Each citation includes title, author, author affiliation, date of publication, and source. The citations are listed in chronological order (most recent first) in each of the subject categories for which this search was made. The RECON accession number is also given.

Darnell, A.J.; Eichelberger, R.L.

1982-03-19T23:59:59.000Z

210

Injection Molding of Plastics from Agricultural Materials  

SciTech Connect

The objective of this research was to conduct a systematic study to relate injection molding parameters to properties of blends of starch and synthetic polymer. From this study, we wished to develop a thorough understanding of the injection molding process and gain significant insight into designing molds and aiding in developing products cheaply and efficiently.

Bhattacharya, M.; Ruan, R.

2001-02-22T23:59:59.000Z

211

Cerro Prieto cold water injection: effects on nearby production wells  

DOE Green Energy (OSTI)

The liquid-dominated Cerro Prieto geothermal field of northern Baja California, Mexico has been under commercial exploitation since 1973. During the early years of operation, all waste brines were sent to an evaporation pond built west of the production area. In 1989, cooled pond brines began to be successfully injected into the reservoir along the western boundary of the geothermal system. The injection rate varied over the years, and is at present about 20% of the total fluid extracted. As expected under the continental desert conditions prevailing in the area, the temperature and salinity of the pond brines change with the seasons, being higher during the summer and lower during the winter. The chemistry of pond brines is also affected by precipitation of silica, oxidation of H{sub 2}S and reaction with airborne clays. Several production wells in the western part of the field (CP-I area) showed beneficial effects from injection. The chemical (chloride, isotopic) and physical (enthalpy, flow rate) changes observed in producers close to the injectors are reviewed. Some wells showed steam flow increases, in others steam flow decline rates flattened. Because of their higher density, injected brines migrated downward in the reservoir and showed up in deep wells.

Truesdell, A.H.; Lippmann, M.J.; De Leon, J.; Rodriguez, M.H.

1999-07-01T23:59:59.000Z

212

New Pellet Injection Schemes on DIII-D  

SciTech Connect

The pellet fueling system on DIII-D has been modified for injection of deuterium pellets from two vertical ports and two inner wall locations on the magnetic high-field side (HFS) of the tokamak. The HFS pellet injection technique was first employed on ASDEX-Upgrade with significant improvements reported in both pellet penetration and fueling efficiency. The new pellet injection schemes on DIII-D required the installation of new guide tubes. These lines are {approx_equal}12.5 m in total length and are made up of complex bends and turns (''roller coaster'' like) to route pellets from the injector to the plasma, including sections inside the torus. The pellet speed at which intact pellets can survive through the curved guide tubes is limited ({approx_equal}200-300 m/s for HFS injection schemes). Thus, one of the three gas guns on the injector was modified to provide pellets in a lower speed regime than the original guns (normal speed range {approx_equal}500 to 1000 m/s). The guide tube installations and gun modifications are described along with the injector operating parameters, and the latest test results are highlighted.

Anderson, P.M.; Baylor, L.R.; Combs, S.K.; Foust, C.R.; Jernigan, T.C.; Robinson, J.I.

1999-11-13T23:59:59.000Z

213

Effects of secondary air injection during cold start of SI engines  

E-Print Network (OSTI)

The paucity of exhaust oxygen during cold start of automobile SI engines limits the extent of exothermic chemical reactions in the exhaust port, manifold, and catalyst. The injection of air into the exhaust system therefore ...

Lee, Dongkun

2010-01-01T23:59:59.000Z

214

Optical injection and terahertz detection of the macroscopic Berry curvature  

E-Print Network (OSTI)

We propose an experimental scheme to probe the Berry curvature of solids. Our method is sensitive to arbitrary regions of the Brillouin zone, and employs only basic optical and terahertz techniques to yield a background free signal. Using semiconductor quantum wells as a prototypical system, we discuss how to inject Berry curvature macroscopically, and probe it in a way that provides information about the underlying microscopic Berry curvature.

Kuljit S. Virk; J. E. Sipe

2011-08-19T23:59:59.000Z

215

Optical injection and terahertz detection of the macroscopic Berry curvature  

E-Print Network (OSTI)

We propose an experimental scheme to probe the Berry curvature of solids. Our method is sensitive to arbitrary regions of the Brillouin zone, and employs only basic optical and terahertz techniques to yield a background free signal. Using semiconductor quantum wells as a prototypical system, we discuss how to inject Berry curvature macroscopically, and probe it in a way that provides information about the underlying microscopic Berry curvature.

Virk, Kuljit S

2011-01-01T23:59:59.000Z

216

Drilling Waste Management Fact Sheet: Slurry Injection of Drilling Wastes  

NLE Websites -- All DOE Office Websites (Extended Search)

Slurry Injection Slurry Injection Fact Sheet - Slurry Injection of Drilling Wastes Underground Injection of Drilling Wastes Several different approaches are used for injecting drilling wastes into underground formations for permanent disposal. Salt caverns are described in a separate fact sheet. This fact sheet focuses on slurry injection technology, which involves grinding or processing solids into small particles, mixing them with water or some other liquid to make a slurry, and injecting the slurry into an underground formation at pressures high enough to fracture the rock. The process referred to here as slurry injection has been given other designations by different authors, including slurry fracture injection (this descriptive term is copyrighted by a company that provides slurry injection services), fracture slurry injection, drilled cuttings injection, cuttings reinjection, and grind and inject.

217

Integrated injection-locked semiconductor diode laser  

DOE Patents (OSTI)

A continuous wave integrated injection-locked high-power diode laser array is provided with an on-chip independently-controlled master laser. The integrated injection locked high-power diode laser array is capable of continuous wave lasing in a single near-diffraction limited output beam at single-facet power levels up to 125 mW (250 mW total). Electronic steering of the array emission over an angle of 0.5 degrees is obtained by varying current to the master laser. The master laser injects a laser beam into the slave array by reflection of a rear facet. 18 figures.

Hadley, G.R.; Hohimer, J.P.; Owyoung, A.

1991-02-19T23:59:59.000Z

218

Integrated injection-locked semiconductor diode laser  

DOE Patents (OSTI)

A continuous wave integrated injection-locked high-power diode laser array is provided with an on-chip independently-controlled master laser. The integrated injection locked high-power diode laser array is capable of continuous wave lasing in a single near-diffraction limited output beam at single-facet power levels up to 125 mW (250 mW total). Electronic steering of the array emission over an angle of 0.5 degrees is obtained by varying current to the master laser. The master laser injects a laser beam into the slave array by reflection of a rear facet.

Hadley, G. Ronald (Albuquerque, NM); Hohimer, John P. (Albuquerque, NM); Owyoung, Adelbert (Albuquerque, NM)

1991-01-01T23:59:59.000Z

219

V-075: EMC AlphaStor Command Injection and Format String Flaws Let Remote  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

5: EMC AlphaStor Command Injection and Format String Flaws Let 5: EMC AlphaStor Command Injection and Format String Flaws Let Remote Users Execute Arbitrary Code V-075: EMC AlphaStor Command Injection and Format String Flaws Let Remote Users Execute Arbitrary Code January 23, 2013 - 12:26am Addthis PROBLEM: EMC AlphaStor Command Injection and Format String Flaws Let Remote Users Execute Arbitrary Code PLATFORM: EMC AlphaStor 4.0 prior to build 800 (All platforms) ABSTRACT: Two vulnerabilities were reported in EMC AlphaStor. REFERENCE LINKS: ESA-2013-008: SecurityTracker Alert ID: 1028020 Secunia Advisory SA51930 CVE-2013-0928 CVE-2013-0929 IMPACT ASSESSMENT: Medium DISCUSSION: A remote user can send a specially crafted DCP run command to inject commands and cause the Device Manager (rrobotd.exe) to execute arbitrary code on the target system [CVE-2013-0928].

220

Injectivity Test At Fenton Hill Hdr Geothermal Area (Grigsby, Et Al., 1983)  

Open Energy Info (EERE)

Injectivity Test At Fenton Hill Hdr Geothermal Area (Grigsby, Et Al., 1983) Injectivity Test At Fenton Hill Hdr Geothermal Area (Grigsby, Et Al., 1983) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Injectivity Test At Fenton Hill Hdr Geothermal Area (Grigsby, Et Al., 1983) Exploration Activity Details Location Fenton Hill Hdr Geothermal Area Exploration Technique Injectivity Test Activity Date Usefulness not indicated DOE-funding Unknown References C. O. Grigsby, J. W. Tester, P. E. Trujillo, D. A. Counce, J. Abbott, C. E. Holley, L. A. Blatz (1983) Rock-Water Interactions In Hot Dry Rock Geothermal Systems- Field Investigations Of In Situ Geochemical Behavior Retrieved from "http://en.openei.org/w/index.php?title=Injectivity_Test_At_Fenton_Hill_Hdr_Geothermal_Area_(Grigsby,_Et_Al.,_1983)&oldid=511318

Note: This page contains sample records for the topic "injection dsi systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

U-218: Cisco Linksys WMB54G TFTP Command Injection Vulnerability |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

18: Cisco Linksys WMB54G TFTP Command Injection Vulnerability 18: Cisco Linksys WMB54G TFTP Command Injection Vulnerability U-218: Cisco Linksys WMB54G TFTP Command Injection Vulnerability July 23, 2012 - 6:49am Addthis PROBLEM: Cisco Linksys WMB54G TFTP Command Injection Vulnerability PLATFORM: Cisco Linksys WMB54G 1.x ABSTRACT: System access from local network reference LINKS: Bugtraq ID: 54615 Original Advisory Secunia Advisory SA49868 Cisco Advisory ID: cisco-sa-20111019-cs IMPACT ASSESSMENT: Medium Discussion: A vulnerability in Cisco Linksys WMB54G was reported, which can be exploited by malicious people to compromise a vulnerable device. The vulnerability is caused due to missing input validation in the TFTP service when running the firmware update functionality and can be exploited to inject and execute arbitrary shell commands. Additionally, it may be

222

V-075: EMC AlphaStor Command Injection and Format String Flaws Let Remote  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

5: EMC AlphaStor Command Injection and Format String Flaws Let 5: EMC AlphaStor Command Injection and Format String Flaws Let Remote Users Execute Arbitrary Code V-075: EMC AlphaStor Command Injection and Format String Flaws Let Remote Users Execute Arbitrary Code January 23, 2013 - 12:26am Addthis PROBLEM: EMC AlphaStor Command Injection and Format String Flaws Let Remote Users Execute Arbitrary Code PLATFORM: EMC AlphaStor 4.0 prior to build 800 (All platforms) ABSTRACT: Two vulnerabilities were reported in EMC AlphaStor. REFERENCE LINKS: ESA-2013-008: SecurityTracker Alert ID: 1028020 Secunia Advisory SA51930 CVE-2013-0928 CVE-2013-0929 IMPACT ASSESSMENT: Medium DISCUSSION: A remote user can send a specially crafted DCP run command to inject commands and cause the Device Manager (rrobotd.exe) to execute arbitrary code on the target system [CVE-2013-0928].

223

Intradermal needle-free powdered drug injection  

E-Print Network (OSTI)

This thesis presents a new method for needle-free powdered drug injection. The design, construction, and testing of a bench-top helium-powered device capable of delivering powder to controllable depths within the dermis ...

Liu, John (John Hsiao-Yung)

2012-01-01T23:59:59.000Z

224

Efficient Spin Injection using Tunnel Injectors  

Science Conference Proceedings (OSTI)

Semiconductor spintronics aims to develop novel sensor, memory and logic devices by manipulating the spin states of carriers in semiconducting materials. This talk will focus on electrical spin injection into semiconductors, which is a prerequisite for ...

Xin Jiang

2005-07-01T23:59:59.000Z

225

U-129: RSA enVision Bugs Permit Cross-Site Scripting, SQL Injection, and  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

9: RSA enVision Bugs Permit Cross-Site Scripting, SQL 9: RSA enVision Bugs Permit Cross-Site Scripting, SQL Injection, and Directory Traversal Attacks U-129: RSA enVision Bugs Permit Cross-Site Scripting, SQL Injection, and Directory Traversal Attacks March 20, 2012 - 7:00am Addthis PROBLEM: RSA enVision Bugs Permit Cross-Site Scripting, SQL Injection, and Directory Traversal Attacks PLATFORM: 4.x, prior to 4.1 Patch 4 ABSTRACT: Several vulnerabilities were reported in RSA enVision. A remote user can access the system. A remote authenticated user can conduct cross-site scripting attacks. A remote authenticated user can inject SQL commands. A remote authenticated user can view files on the target system. Reference LINKS: SecurityTracker Alert ID: 1026819 CVE-2012-0403 IMPACT ASSESSMENT: High Discussion: The system does not properly filter HTML code from user-supplied input

226

Cerro Prieto cold water injection: effects on nearby production wells  

E-Print Network (OSTI)

reservoir wells close to injection well E-6 along with theMeeting. Most of the injection wells are open to the Alphaand completing new injection wells is lower than in the East

Truesdell, A.H.

2010-01-01T23:59:59.000Z

227

Pulser injection with subsequent removal for gamma-ray spectrometry  

DOE Patents (OSTI)

An improved system for gamma-ray spectroscopy characterized by an interface module that controls the injection of electronic pulses as well as separation logic that enables storage of pulser events in a region of the spectrum of a multichannel analyzer distinct from the region reserved for storage of gamma-ray events. The module accomplishes this by tagging pulser events (high or low) injected into the amplification circuitry, adding an offset to the events so identified at the time the events are at the output of the analog to digital converter, and storing such events in the upper portion of the spectrum stored in the multichannel analyzer. The module can be adapted for use with existing gamma-ray spectroscopy equipment to provide for automatic analyses of radioisotopes. 7 figs.

Hartwell, J.K.; Goodwin, S.G.; Johnson, L.O.; Killian, E.W.

1989-02-01T23:59:59.000Z

228

Application of Gaseous Sphere Injection Method for Modeling Under-expanded H2 Injection  

DOE Green Energy (OSTI)

A methodology for modeling gaseous injection has been refined and applied to recent experimental data from the literature. This approach uses a discrete phase analogy to handle gaseous injection, allowing for addition of gaseous injection to a CFD grid without needing to resolve the injector nozzle. This paper focuses on model testing to provide the basis for simulation of hydrogen direct injected internal combustion engines. The model has been updated to be more applicable to full engine simulations, and shows good agreement with experiments for jet penetration and time-dependent axial mass fraction, while available radial mass fraction data is less well predicted.

Whitesides, R; Hessel, R P; Flowers, D L; Aceves, S M

2010-12-03T23:59:59.000Z

229

U-058: Apache Struts Conversion Error OGNL Expression Injection...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

8: Apache Struts Conversion Error OGNL Expression Injection Vulnerability U-058: Apache Struts Conversion Error OGNL Expression Injection Vulnerability December 12, 2011 - 9:00am...

230

Calculating the probability of injected carbon dioxide plumes encountering faults  

E-Print Network (OSTI)

Change Special Report on Carbon Dioxide Capture and Storage,Probability of Injected Carbon Dioxide Plumes Encounteringthe probability of injected carbon dioxide encountering and

Jordan, P.D.

2013-01-01T23:59:59.000Z

231

Texas Natural Gas Injections into Underground Storage (Million...  

Gasoline and Diesel Fuel Update (EIA)

View History: Monthly Annual Download Data (XLS File) Texas Natural Gas Injections into Underground Storage (Million Cubic Feet) Texas Natural Gas Injections into Underground...

232

Alabama Injection Project Aimed at Enhanced Oil Recovery, Testing...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Alabama Injection Project Aimed at Enhanced Oil Recovery, Testing Important Geologic CO2 Storage Alabama Injection Project Aimed at Enhanced Oil Recovery, Testing Important...

233

Trona Injection Tests: Mirant Potomac River Station, Unit 1,...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Trona Injection Tests: Mirant Potomac River Station, Unit 1, November 12 to December 23, 2005, Summary Report Trona Injection Tests: Mirant Potomac River Station, Unit 1, November...

234

Idaho Natural Gas Underground Storage Injections All Operators...  

Gasoline and Diesel Fuel Update (EIA)

Underground Storage Injections All Operators (Million Cubic Feet) Idaho Natural Gas Underground Storage Injections All Operators (Million Cubic Feet) Decade Year-0 Year-1 Year-2...

235

Connecticut Natural Gas Underground Storage Injections All Operators...  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Injections All Operators (Million Cubic Feet) Connecticut Natural Gas Underground Storage Injections All Operators (Million Cubic Feet) Decade Year-0 Year-1...

236

Alaska Natural Gas Underground Storage Injections All Operators...  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Injections All Operators (Million Cubic Feet) Alaska Natural Gas Underground Storage Injections All Operators (Million Cubic Feet) Decade Year-0 Year-1 Year-2...

237

Delaware Natural Gas Underground Storage Injections All Operators...  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Injections All Operators (Million Cubic Feet) Delaware Natural Gas Underground Storage Injections All Operators (Million Cubic Feet) Decade Year-0 Year-1 Year-2...

238

Wisconsin Natural Gas Underground Storage Injections All Operators...  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Injections All Operators (Million Cubic Feet) Wisconsin Natural Gas Underground Storage Injections All Operators (Million Cubic Feet) Decade Year-0 Year-1...

239

Georgia Natural Gas Underground Storage Injections All Operators...  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Injections All Operators (Million Cubic Feet) Georgia Natural Gas Underground Storage Injections All Operators (Million Cubic Feet) Decade Year-0 Year-1 Year-2...

240

New Jersey Natural Gas Underground Storage Injections All Operators...  

U.S. Energy Information Administration (EIA) Indexed Site

Pages: Injections of Natural Gas into Underground Storage - All Operators New Jersey Underground Natural Gas Storage - All Operators Injections of Natural Gas into Storage...

Note: This page contains sample records for the topic "injection dsi systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

South Carolina Natural Gas Underground Storage Injections All...  

U.S. Energy Information Administration (EIA) Indexed Site

Pages: Injections of Natural Gas into Underground Storage - All Operators South Carolina Underground Natural Gas Storage - All Operators Injections of Natural Gas into Storage...

242

North Carolina Natural Gas Underground Storage Injections All...  

U.S. Energy Information Administration (EIA) Indexed Site

Pages: Injections of Natural Gas into Underground Storage - All Operators North Carolina Underground Natural Gas Storage - All Operators Injections of Natural Gas into Storage...

243

Illinois Natural Gas Injections into Underground Storage (Million...  

Gasoline and Diesel Fuel Update (EIA)

Injections into Underground Storage (Million Cubic Feet) Illinois Natural Gas Injections into Underground Storage (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct...

244

Epidemiology of HIV Among Injecting and Non-injecting Drug Users: Current Trends and Implications for Interventions  

E-Print Network (OSTI)

might inject drugs worldwide [1•]. China, the United States,China, the United States, and Russia, the three leading countries for injecting drugChina Russia USA Fig. 1 Number and proportion of HIV infection among injecting drug

Strathdee, Steffanie A.; Stockman, Jamila K.

2010-01-01T23:59:59.000Z

245

Pulsed sextupole injection for Beijing Advanced Photon Source with ultralow emittance  

E-Print Network (OSTI)

In this paper we present the physical design of the pulsed sextupole injection system for Beijing Advanced Photon Source (BAPS) with an ultralow emittance. The BAPS ring lattice is designed in such a way that two options of pulsed sextupole injection are allowed, i.e., with septum and pulsed sextupole in different drift spaces or in the same drift space. We give the magnetic parameters of the injection system and the optimal condition of the optical functions for both options. In addition, we find that the pulsed sextupole induces position-dependent dispersive effect and causes non-ignorable effect on the injection efficiency in a storage ring with a relatively small acceptance, which should be well considered.

Yi, JIAO

2013-01-01T23:59:59.000Z

246

Model study of historical injection in the Southeast Geysers  

DOE Green Energy (OSTI)

A three component model study of the historical injection of two wells in the Unit 13 area demonstrates that the recovery of injection derived steam is influenced by the geologic structure of the bottom of the reservoir and the relative location of injection wells. the migration of injectate from the first injection well, located up structure from the second, quenched the area around the second injector before it started operation. while both wells had similar cumulative mass injected, nearly five times more injection derived steam is recovered from the first injector than the second. Sensitivity runs were made to three cases of increasing matrix capillary pressure. The recovery of injection derived steam increases with higher values of capillarity. The interaction of structure at the bottom of the reservoir, injection well locations, and matrix capillarity all influence the recovery efficiency of injectate as steam. The model developed in this study will be used to evaluate injection strategies at The Geysers.

Faulder, D.D.

1992-01-01T23:59:59.000Z

247

Model study of historical injection in the southeast Geysers  

DOE Green Energy (OSTI)

A three component model study of the historical injection of two wells in the Unit 13 area demonstrates that the recovery of injection derived steam is influenced by the geologic structure of the bottom of the reservoir and the relative location of injection wells. The migration of injectate from the first injection well, located up structure from the second, quenched the area around the second injector before it started operation. While both wells had similar cumulative mass injected, nearly five times more injection derived steam is recovered from the first injector than the-second. Sensitivity runs were made to three cases of increasing matrix capillary pressure. The recovery of injection derived steam increases with higher values of capillarity. The interaction of structure at the bottom of the reservoir, injection well locations, and matrix capillarity all influence the recovery efficiency of injected as steam. The model developed in this study will be used to evaluate injection strategies at The Geysers.

Faulder, D.D.

1992-08-01T23:59:59.000Z

248

Model study of historical injection in the southeast Geysers  

DOE Green Energy (OSTI)

A three component model study of the historical injection of two wells in the Unit 13 area demonstrates that the recovery of injection derived steam is influenced by the geologic structure of the bottom of the reservoir and the relative location of injection wells. The migration of injectate from the first injection well, located up structure from the second, quenched the area around the second injector before it started operation. While both wells had similar cumulative mass injected, nearly five times more injection derived steam is recovered from the first injector than the-second. Sensitivity runs were made to three cases of increasing matrix capillary pressure. The recovery of injection derived steam increases with higher values of capillarity. The interaction of structure at the bottom of the reservoir, injection well locations, and matrix capillarity all influence the recovery efficiency of injected as steam. The model developed in this study will be used to evaluate injection strategies at The Geysers.

Faulder, D.D.

1992-01-01T23:59:59.000Z

249

Supported-sorbent injection. Final report  

Science Conference Proceedings (OSTI)

A new retrofitable, wastefree acid-rain control concept was pilot-tested at Ohio Edison`s high-sulfur coal-fired R.E. Burger generating station at the 2-MWe level. During the project, moistened {open_quotes}supported{close_quotes} sorbents, made from a combination of lime and vermiculite or perlite, were injected into a humidified 6,500-acfm flue-gas slipstream. After the sorbents reacted with the sulfur dioxide in the flue gas, they were removed from ductwork with a cyclone and baghouse. The $1.0 million project was co-funded by Sorbent Technologies Corporation, the Ohio Edison Company, and the Ohio Coal Development Office. The project included a preliminary bench-scale testing phase, construction of the pilot plant, parametric studies, numerous series of recycle tests, and a long-term run. The project proceeded as anticipated and achieved its expected results. This duct injection technology successfully demonstrated SO{sub 2}-removal rates of 80 to 90% using reasonable stoichiometric injection ratios (2:1 Ca:S) and approach temperatures (20-25F). Under similar conditions, dry injection of hydrated lime alone typically only achieves 40 to 50% SO{sub 2} removal. During the testing, no difficulties were encountered with deposits in the ductwork or with particulate control, which have been problems in tests of other duct-injection schemes.

Nelson, S. Jr.

1997-07-01T23:59:59.000Z

250

Prototype demonstration of dual sorbent injection for acid gas control on municipal solid waste combustion units  

SciTech Connect

This report gathered and evaluated emissions and operations data associated with furnace injection of dry hydrated lime and duct injection of dry sodium bicarbonate at a commercial, 1500 ton per day, waste-to-energy facility. The information compiled during the project sheds light on these sorbents to affect acid gas emissions from municipal solid waste combustors. The information assesses the capability of these systems to meet the 1990 Clean Air Act and 1991 EPA Emission Guidelines.

None

1994-05-01T23:59:59.000Z

251

Apparatus and method to inject a reductant into an exhaust gas feedstream  

DOE Patents (OSTI)

An exhaust aftertreatment system for an internal combustion engine is provided including an apparatus and method to inject a reductant into the exhaust gas feedstream. Included is a fuel metering device adapted to inject reductant into the exhaust gas feedstream and a controllable pressure regulating device. A control module is operatively connected to the reductant metering device and the controllable pressure regulating device, and, adapted to effect flow of reductant into the exhaust gas feedstream over a controllable flow range.

Viola, Michael B. (Macomb Township, MI)

2009-09-22T23:59:59.000Z

252

Optimization of Trona/Limestone Injection for SO2 Control in Coal-Fired Boilers  

SciTech Connect

Mobotec USA develops and markets air pollution control systems for utility boilers and other combustion systems. They have a particular interest in technologies that can reduce NOx, SOx, and mercury emissions from coal-fired boilers, and have been investigating the injection of sorbents such as limestone and trona into a boiler to reduce SOx and Hg emissions. WRI proposed to use the Combustion Test Facility (CTF) to enable Mobotec to conduct a thorough evaluation of limestone and trona injection for SO{sub 2} control. The overall goal of the project was to characterize the SO{sub 2} reductions resulting from the injection of limestone and trona into the CTF when fired with a high-sulfur eastern bituminous coal used in one of Mobotec's Midwest installations. Results revealed that when limestone was injected at Ca:S molar ratios of 1.5 to 3.0, the resulting SO{sub 2} reductions were 35-55%. It is believed that further reductions can be attained with improved mixing of the sorbent with the combustion gases. When limestone was added to the coal, at Ca:S molar ratios of 0.5 to 1.5, the SO{sub 2} reductions were 13-21%. The lower reductions were attributed to dead-burning of the sorbent in the high temperature flame zone. In cases where limestone was both injected into the furnace and added to the coal, the total SO{sub 2} reductions for a given Ca:S molar ratio were similar to the reductions for furnace injection only. The injection of trona into the mid-furnace zone, for Na:S molar ratios of 1.4 to 2.4, resulted in SO{sub 2} reductions of 29-43%. Limestone injection did not produce any slag deposits on an ash deposition probe while trona injection resulted in noticeable slag deposition.

None

2005-09-01T23:59:59.000Z

253

Assessment of Injection Well Construction and Operation for Water Injection Wells and Salt Water Disposal Wells  

E-Print Network (OSTI)

Assessment of Injection Well Construction and Operation for Water Injection Wells and Salt Water Disposal Wells in the Nine Township Area ­ 2009 September 2009 Prepared by Delaware Basin Drilling from EPA to DOE dated 7/16/2009) 1 Solution Mining Practices 1 Recent Well Failures 2 The Mechanism

254

Interaction between Injection Points during Hydraulic Fracturing  

E-Print Network (OSTI)

We present a model of the hydraulic fracturing of heterogeneous poroelastic media. The formalism is an effective continuum model that captures the coupled dynamics of the fluid pressure and the fractured rock matrix and models both the tensile and shear failure of the rock. As an application of the formalism, we study the geomechanical stress interaction between two injection points during hydraulic fracturing (hydrofracking) and how this interaction influences the fracturing process. For injection points that are separated by less than a critical correlation length, we find that the fracturing process around each point is strongly correlated with the position of the neighboring point. The magnitude of the correlation length depends on the degree of heterogeneity of the rock and is on the order of 30-45 m for rocks with low permeabilities. In the strongly correlated regime, we predict a novel effective fracture-force that attracts the fractures toward the neighboring injection point.

Hals, Kjetil M D

2012-01-01T23:59:59.000Z

255

Definition: Injectivity Test | Open Energy Information  

Open Energy Info (EERE)

Definition Definition Edit with form History Facebook icon Twitter icon » Definition: Injectivity Test Jump to: navigation, search Dictionary.png Injectivity Test A well testing technique conducted upon completion of a well. Water is pumped into the well at a constant rate until a stable pressure is reached then the pump is turned off and the rate at which pressure decreases is measured. The pressure measurements are graphed and well permeability can be calculated.[1] References ↑ https://pangea.stanford.edu/ERE/pdf/IGAstandard/ISS/2008Croatia/Hole03.pdf Ret LikeLike UnlikeLike You and one other like this.One person likes this. Sign Up to see what your friends like. rieved from "http://en.openei.org/w/index.php?title=Definition:Injectivity_Test&oldid=688681"

256

Energy Injection in GRB Afterglow Models  

E-Print Network (OSTI)

We extend the standard fireball model, widely used to interpret gamma-ray burst (GRB) afterglow light curves, to include energy injections, and apply the model to the afterglow light curves of GRB 990510, GRB 000301C and GRB 010222. We show that discrete energy injections can cause temporal variations in the optical light curves and present fits to the light curves of GRB 000301C as an example. A continuous injection may be required to interpret other bursts such as GRB 010222. The extended model accounts reasonably well for the observations in all bands ranging from X-rays to radio wavelengths. In some cases, the radio light curves indicate that additional model ingredients may be needed.

Gudlaugur Johannesson; Gunnlaugur Bjornsson; Einar H. Gudmundsson

2006-05-11T23:59:59.000Z

257

A study on Raman Injection Laser  

E-Print Network (OSTI)

The Raman Injection Laser is a new type of laser which is based on triply resonant stimulated Raman scattering between quantum confined states within the active region of a Quantum Cascade Laser that serves as an internal optical pump. The Raman Injection Laser is driven electrically and no external laser pump is required. Triple resonance leads to an enhancement of orders of magnitude in the Raman gain, high conversion efficiency and low threshold. We studied this new type of laser and conclude some basic equations. With reasonable experimental parameters, we calculated the laser gain, losses and the output power of the Raman Injection Laser by using Mathematica and FEMLab. Finally we compared the theoretical and experimental results.

Liu, Debin

2005-08-01T23:59:59.000Z

258

NETL: Mercury Emissions Control Technologies - Long-Term Carbon Injection  

NLE Websites -- All DOE Office Websites (Extended Search)

Long-Term Carbon Injection Field Test for > 90% Long-Term Carbon Injection Field Test for > 90% Mercury Removal for a PRB Unit with a Spray Drier and Fabric Filter The intent of DOE's Phase I and II field tests was to work with industry to evaluate the most promising mercury control technologies at full-scale in a variety of configurations. Although longer-term tests were conducted, the test period was not sufficient to answer many fundamental questions about long-term consistency of mercury removal and reliability of the system when integrated with plant processes. As the technologies move towards commercial implementation, it is critical to accurately define the mercury removal performance and costs so that power companies and policy makers can make informed decisions. Therefore, the overall objective of this Phase III project is to determine the mercury removal performance, long-term emissions variability, and associated O&M costs of activated carbon injection for >90% mercury control over a 10 to 12 month period on a unit that represents the combination of coal and emission control equipment that will be used for many new and existing power plants.

259

The feasibility of deep well injection for brine disposal  

E-Print Network (OSTI)

A generalized methodology for evaluating the technical feasibility of projects involving the disposal of waste brine by injection into deep saline aquifers is developed, primarily from the hydrology and petroleum engineering literature. Data collection, groundwater modeling, and fluid compatibility are discussed in detail. Injection system design, economics, and regulatory considerations are more related to economic than technical feasibility, and are discussed only as they relate to technical feasibility. The methodology is utilized to make a preliminary evaluation of a proposed brine injection project in the Dove Creek area of King and Stonewall Counties, North Central Texas. Four known deep aquifers are modeled, using the SWIFT/486 software, to determine their ability to receive two cfs of brine for a project life of one hundred years. Two aquifers, the Strawn and EUenburger Formations, are predicted to be acceptable for disposal. Each aquifer would require only one disposal well which is favorable for the economics of the project. Additional data, particularly hydraulic conductivity and net aquifer thickness data, are required to make a more definitive technical feasibility determination for this project.

Spongberg, Martin Edward

1994-01-01T23:59:59.000Z

260

Use of off-axis injection as an alternative to geometrically merging beams in an energy-recovering linac  

DOE Patents (OSTI)

A method of using off-axis particle beam injection in energy-recovering linear accelerators that increases operational efficiency while eliminating the need to merge the high energy re-circulating beam with an injected low energy beam. In this arrangement, the high energy re-circulating beam and the low energy beam are manipulated such that they are within a predetermined distance from one another and then the two immerged beams are injected into the linac and propagated through the system. The configuration permits injection without geometric beam merging as well as decelerated beam extraction without the use of typical beamline elements.

Douglas, David R. (York County, VA)

2012-01-10T23:59:59.000Z

Note: This page contains sample records for the topic "injection dsi systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Injected Beam Dynamics in SPEAR3  

SciTech Connect

For the top-off operation it is important to understand the time evolution of charge injected into the storage ring. The large-amplitude horizontal oscillation quickly filaments and decoheres, and in some cases exhibits non-linear x-y coupling before damping to the stored orbit. Similarly, in the longitudinal dimension, any mismatch in beam arrival time, beam energy or phase-space results in damped, non-linear synchrotron oscillations. In this paper we report on measurements of injection beam dynamics in the transverse and longitudinal planes using turn-by-turn BPMs, a fast-gated, image-intensified CCD camera and a Hamamatsu C5680 streak camera.

Corbett, Jeff; /SLAC; Fisher, Alan; /SLAC; Huang, Xiaobiao; /SLAC; Safranek, James; /SLAC; Westerman, Stuart; /SLAC; Cheng, Weixing; /Brookhaven; Mok, Walter; /Unlisted

2012-06-21T23:59:59.000Z

262

Interphase power controller with voltage injection  

Science Conference Proceedings (OSTI)

This paper introduces a new family of Interphase Power Controllers (IPC) based on the principle of voltage injection commonly used in phase-shifting transformers (PST). The voltage injection IPC exhibits power (active and reactive) control characteristics similar to previously defined IPC's and retains their inherent qualities: passive control, short circuit limitation and voltage decoupling. It also provides more flexibility for the adjustment of the operating points. Two promising topologies are described in more detail. One of them offers the potential of retrofitting existing phase-shifting transformers into full-fledged IPC's.

Beauregard, F.; Brochu, J.; Morin, G.; Pelletier, P. (Centre d'Innovation sur le Transport d'Energie du Quebec, Varennes, Quebec (Canada))

1994-10-01T23:59:59.000Z

263

Non-isothermal CO2 flow through an injection well  

E-Print Network (OSTI)

Non-isothermal CO2 flow through an injection well Orlando SilvaOrlando Silva #12; The Problem CO2 or gas injection well Questions Injection of scCO2 vs. gaseous CO2. Other relevant examples: - gas and therefore the CO2 injection rate. caprock reservoir geothermal gradient hydrostatic gradient well CO2 bubble

Politècnica de Catalunya, Universitat

264

Discussion on Cycle Water Injection Effect and Its Influencing Factors  

Science Conference Proceedings (OSTI)

Cyclic waterflooding is a kind of waterflood technique, which can improve the waterflood efficiency in low-permeability and fracture-porosity reservoir by changing periodically injected water volume. This article gives the principle and the applied conditions ... Keywords: water flooding, principle, the opportunity of water injection, water injection efficiency, water injection period

Shan Wuyi, Zhang Xue

2013-06-01T23:59:59.000Z

265

Experiences from First Top-Off Injection at the Stanford Synchrotron Radiation Lightsource  

Science Conference Proceedings (OSTI)

As the Stanford Synchrotron Radiation Lightsource (SSRL) of the SLAC National Accelerator Laboratory (SLAC) is moving toward Top-Off injection mode, SLAC's Radiation Protection Department is working with SSRL on minimizing the radiological hazards of this mode. One such hazard is radiation that is created inside the accelerator concrete enclosure by injected beam. Since during Top-Off injection the stoppers that would otherwise isolate the storage ring from the experimental area stay open, the stoppers no longer prevent such radiation from reaching the experimental area. The level of this stray radiation was measured in April 2008 during the first Top-Off injection tests. They revealed radiation dose rates of up to 18 microSv/h (1.8 millirem/h) outside the experimental hutches, significantly higher than our goal of 1 microSv/h (0.1 millirem/h). Non-optimal injection increased the measured dose rates by a factor two. Further tests in 2008 indicated that subsequent improvements by SSRL to the injection system have reduced the dose rates to acceptable levels. This presentation describes the studies performed before the Top-Off tests, the tests themselves and their major results (both under initial conditions and after improvements were implemented), and presents the controls being implemented for full and routine Top-Off injection.

Bauer, J.M.; Liu, J.C.; Prinz, A.; Rokni, S.H.; /SLAC

2009-12-11T23:59:59.000Z

266

FURNACE INJECTION OF ALKALINE SORBENTS FOR SULFURIC ACID CONTROL  

Science Conference Proceedings (OSTI)

This document summarizes progress on Cooperative Agreement DE-FC26-99FT40718, Furnace Injection of Alkaline Sorbents for Sulfuric Acid Control, during the time period April 1, 2003 through September, 2003. The objective of this project is to demonstrate the use of alkaline reagents injected into the furnace of coal-fired boilers as a means of controlling sulfuric acid emissions. The coincident removal of hydrochloric acid and hydrofluoric acid is also being determined, as is the removal of arsenic, a known poison for NO{sub x} selective catalytic reduction (SCR) catalysts. EPRI, the Tennessee Valley Authority (TVA), FirstEnergy Corporation, American Electric Power (AEP) and the Dravo Lime Company are project co-funders. URS Group is the prime contractor. This is the eighth reporting period for the subject Cooperative Agreement. During previous reporting periods, two long-term sorbent injection tests were conducted, one on Unit 3 at FirstEnergy's Bruce Mansfield Plant (BMP) and one on Unit 1 at AEP's Gavin Plant. Those tests determined the effectiveness of injecting alkaline slurries into the upper furnace of the boiler as a means of controlling sulfuric acid emissions from these units. The alkaline slurries tested included commercially available magnesium hydroxide slurry (Gavin Plant), and a byproduct magnesium hydroxide slurry (both Gavin Plant and BMP). The tests showed that injecting either the commercial or the byproduct magnesium hydroxide slurry could achieve up to 70-75% overall sulfuric acid removal. At BMP, the overall removal was limited by the need to maintain acceptable electrostatic precipitator (ESP) particulate control performance. At Gavin Plant, the overall sulfuric acid removal was limited because the furnace injected sorbent was less effective at removing SO{sub 3} formed across the SCR system installed on the unit for NO{sub x} control than at removing SO{sub 3} formed in the furnace. The SO{sub 3} removal results were presented in the semi-annual Technical Progress Report for the time period April 1, 2001 through September 30, 2001. Additional balance of plant impact information for the two tests was reported in the Technical Progress Report for the time period October 1, 2001 through March 30, 2002. Additional information became available about the effects of byproduct magnesium hydroxide injection on SCR catalyst coupons during the long-term test at BMP, and those results were reported in the report for the time period April 1, 2002 through September 30, 2002. During the current period, process economic estimates were developed, comparing the costs of the furnace magnesium hydroxide slurry injection process tested as part of this project to a number of other candidate SO{sub 3}/sulfuric acid control technologies for coal-fired power plants. The results of this economic evaluation are included in this progress report.

Gary M. Blythe

2003-10-01T23:59:59.000Z

267

Optimization of injection scheduling in geothermal fields  

DOE Green Energy (OSTI)

This study discusses the application of algorithms developed in Operations Research to the optimization of brine reinjection in geothermal fields. The injection optimization problem is broken into two sub-problems: (1) choosing a configuration of injectors from an existing set of wells, and (2) allocating a total specified injection rate among chosen injectors. The allocation problem is solved first. The reservoir is idealized as a network of channels or arcs directly connecting each pair of wells in the field. Each arc in the network is considered to have some potential for thermal breakthrough. This potential is quantified by an arc-specific break-through index, b/sub ij/, based on user-specified parameters from tracer tests, field geometry, and operating considerations. The sum of b/sub ij/-values for all arcs is defined as the fieldwide breakthrough index, B. Injection is optimized by choosing injection wells and rates so as to minimize B subject to constraints on the number of injectors and the total amount of fluid to be produced and reinjected. The study presents four computer programs which employ linear or quadratic programming to solve the allocation problem. In addition, a program is presented which solves the injector configuration problem by a combination of enumeration and quadratic programming. The use of the various programs is demonstrated with reference both to hypothetical data and an actual data set from the Wairakei Geothermal Field in New Zealand.

Lovekin, J.

1987-05-01T23:59:59.000Z

268

Optimization of Injection Scheduling in Geothermal Fields  

DOE Green Energy (OSTI)

This study discusses the application of algorithms developed in Operations Research to the optimization of brine reinjection in geothermal fields. The injection optimization problem is broken into two sub-problems: (1) choosing a configuration of injectors from an existing set of wells, and (2) allocating a total specified injection rate among chosen injectors. The allocation problem is solved first. The reservoir is idealized as a network of channels or arcs directly connecting each pair of wells in the field. Each arc in the network is considered to have some potential for thermal breakthrough. This potential is quantified by an arc-specific breakthrough index, b{sub ij}, based on user-specified parameters from tracer tests, field geometry, and operating considerations. The sum of b{sub ij}-values for all arcs is defined as the fieldwide breakthrough index, B. Injection is optimized by choosing injection wells and rates so as to minimize B subject to constraints on the number of injectors and the total amount of fluid to be produced and reinjected. The use of the various methods is demonstrated with reference both to hypothetical data and an actual data set from the Wairakei Geothermal Field in New Zealand.

Lovekin, James; Horne, Roland N.

1989-03-21T23:59:59.000Z

269

Enhancing the use of coals by gas reburning-sorbent injection: Volume 3 -- Gas reburning-sorbent injection at Edwards Unit 1, Central Illinois Light Company. Final report  

Science Conference Proceedings (OSTI)

Design work has been completed for a Gas Reburning-Sorbent Injection (GR-SI) system to reduce emissions of NO{sub x} and SO{sub 2} from a wall fired unit at Central Illinois Light Company`s Edwards Station Unit 1, located in Bartonville, Illinois. The goal of the project was to reduce emissions of NO{sub x} by 60%, from the as found baseline of 0.98 lb/MBtu and to reduce emissions of SO{sub 2} by 50%. Since the unit currently fires a blend of high sulfur Illinois coal and low sulfur Kentucky coal to meet an SO{sub 2} limit of 1.8 lb/MBtu, the goal at this site was amended to meeting this limit while increasing the fraction of high sulfur coal to 57% from the current 15% level. GR-SI requires injection of natural gas into the furnace at the level of the top burner row, creating a fuel-rich zone in which NO{sub x} formed in the coal zone is reduced to N{sub 2}. Recycled flue gas is used to increase the reburning fuel jet momentum, resulting in enhanced mixing. Recycled flue gas is also used to cool the top row of burners which would not be in service during GR operation. Dry hydrated lime sorbent is injected into the upper furnace to react with SO{sub 2}, forming solid CaSO{sub 4} and CaSO{sub 3}, which are collected by the ESP. The system was designed to inject sorbent at a rate corresponding to a calcium (sorbent) to sulfur (coal) molar ratio of 2.0. The SI system design was optimized with respect to gas temperature, injection air flow rate, and sorbent dispersion. Sorbent injection air flow is equal to 3% of the combustion air. The design includes modifications of the ESP, sootblowing, and ash handling systems.

NONE

1996-03-01T23:59:59.000Z

270

Cold-water injection reanalysis for N Reactor  

Science Conference Proceedings (OSTI)

A re-analysis of the cold water injection transient, with a space- dependent, two-dimensional reactor kinetics code TWIGL has been completed. The analyses considered the impact of flux flattening on the consequences of this accident. Separate categories of cold water source were evaluated. Introduction of a sixth steam generator cell, postulated as a significant cold water transient in previous studies, was re-analyzed in greater depth. Activation of the emergency core cooling system (ECCS) and the main steam line break on the secondary side were also evaluated for worst-case condition. In all instances, the results of the analyses confirmed that N Reactor is well protected against the consequences of cold water reactivity transients by appropriate trip settings and by fast acting control systems. Accidents were analyzed for the possibilities that the control rods failed to insert, and safe shutdown was accomplished with the ball backup safety system. All calculations were performed for the flattened core. The flux flattened core did not alter the timing or the severity of the transient. The results of the re-analyses compare favorably with the analysis discussed in N Reactor Updated Safety Analysis Report (NUSAR) (UNI 1978). Total control aspects of cold water injection, a steady-state analysis, are unaffected by the conclusions of this report. The document contains detailed discussion of the computer analyses including the preparation of input, underlying assumptions, code validation discussion, and comparisons to past work. 10 refs., 27 figs.

Toffer, H.; Crowe, R.D.; Fortner, R.L.; Mohr, C.L.

1988-02-01T23:59:59.000Z

271

Portable Electrochemical Sensing System - Available ...  

The device can use either a flow injection system with a mercury-film electrode or a mercury-free system involving the use of functionalized ...

272

Study Reveals Fuel Injection Timing Impact on Particle Number Emissions (Fact Sheet)  

DOE Green Energy (OSTI)

Start of injection can improve environmental performance of fuel-efficient gasoline direct injection engines.

Not Available

2012-12-01T23:59:59.000Z

273

BWRVIP-201: BWR Vessel and Internals Project, Technical Basis For Plant Specific Safety Evaluation for Hydrazine Injection for Start up ECP Reduction in BWRs  

Science Conference Proceedings (OSTI)

This report describes the technical basis for a plant-specific safety evaluation of hydrazine injection into the primary system of a BWR during startup, with the objective of minimizing the electrochemical corrosion potential (ECP), and thereby reducing intergranular stress corrosion cracking (IGSCC). PWR operators have been injecting hydrazine into primary systems at startup for many years with no observed adverse impact on fuel or materials. The report concludes that BWR hydrazine injection is feasible...

2008-11-24T23:59:59.000Z

274

Optimizing injected solvent fraction in stratified reservoirs  

E-Print Network (OSTI)

Waterflooding has become standard practice for extending the productive life of many solution gas drive reservoirs, but has the disadvantage of leaving a substantial residual oil volume in the reservoir. Solvent flooding has been offered as a method whereby oil may be completely displaced from the reservoir, leaving no residual volume. Field results have demonstrated that solvent floods suffer from early solvent breakthrough and considerable oil by-passing owing to high solvent mobility. The injection of both water and solvent has been demonstrated to offer advantages. Water partially mitigates both the adverse mobility and high cost of solvent floods, while solvent mobilizes oil which would be left in the reservoir by water alone. The process is equally applicable to reservoirs currently at residual oil saturation (tertiary floods) and to reservoirs at maximum oil saturation (secondary floods). In stratified reservoirs high permeability layers may be preferentially swept by solvent floods, while low permeability layers may be scarcely swept at all. Presence or absence of transverse communication between layers can modify overall sweep efficiency. This work is a study of water-solvent injection in stratified reservoirs based on computer simulation results. Fractional oil recovery as a function of injected solvent fraction, permeability contrast between layers, initial oil saturation, and presence or absence of transverse communication between strata has been determined. Results are presented as a series of optimization curves. Permeability contrast between layers is shown to be the dominant control on fractional oil recovery. Transverse communicating reservoirs are shown to require a higher solvent-water ratio in order to attain recoveries comparable to transverse noncommunicating reservoirs. In actual field projects, water and solvent are injected alternately as discrete slugs. This process is known as "WAG" for "water-alternating-gas". In the simulations used in this study, continuous water-solvent injection at a fixed fraction rather than true WAG was employed. It is demonstrated that the two methods give equivalent results. In summary, this work is the first comprehensive study of the behavior of stratified reservoirs undergoing water-solvent injection.

Moon, Gary Michael

1993-01-01T23:59:59.000Z

275

Clean Coal III Project: Blast Furnace Granular Coal Injection Project Trial 1 Report - Blast Furnace Granular Coal Injection - Results with Low Volatile Coal  

SciTech Connect

This report describes the first coal trial test conducted with the Blast Furnace Granular Coal Injection System at Bethlehem Steel Corporation's Burns Harbor Plant. This demonstration project is divided into three phases: Phase I - Design Phase II - Construction Phase III - Operation The design phase was conducted in 1991-1993. Construction of the facility began in August 1993 and was completed in late 1994. The coal injection facility began operating in January 1995 and Phase III began in November 1995. The Trial 1 base test orI C furnace was carried out in October 1996 as a comparison period for the analysis of the operation during subsequent coal trials.

1997-11-01T23:59:59.000Z

276

Browse wiki | Open Energy Information  

Open Energy Info (EERE)

Industry (DSI) + Name Denmark Solar Industry (DSI) + OpenEIPageDescription Denmark Solar Industry (DSI): energy company profile. OpenEIPageKeyword Denmark Solar Industry (DSI) +...

277

Injection into a fractured geothermal reservoir  

DOE Green Energy (OSTI)

A detailed study is made on the movement of the thermal fronts in the fracture and in the porous medium when 100{sup 0}C water is injected into a 300{sup 0}C geothermal reservoir with equally spaced horizontal fractures. Numerical modeling calculations were made for a number of thermal conductivity values, as well as different values of the ratio of fracture and rock medium permeabilities. One important result is an indication that although initially, the thermal front in the fracture moves very fast relative to the front in the porous medium as commonly expected, its speed rapidly decreases. At some distance from the injection well the thermal fronts in the fracture and the porous medium coincide, and from that point they advance together. The implication of this result on the effects of fractures on reinjection into geothermal reservoirs is discussed.

Bodvarsson, G.S.; Tsang, C.F.

1980-05-01T23:59:59.000Z

278

Transient fault modeling and fault injection simulation  

E-Print Network (OSTI)

An accurate transient fault model is presented in this thesis. A 7-term exponential current upset model is derived from the results of a device-level, 3-dimensional, single-event-upset simulation. A curve-fitting algorithm is used to extract the numerical model from the empirical data. The model is implemented in a HSPICE simulation environment as a current-injection source for fault simulation. The current transient model is used to conduct electrical-level fault injection simulations on a static RAM cell and subcircuits from two commercial microprocessors. The results from the 7-term exponential model are compared with the results from the widely accepted double-exponential transient model. The experimental data indicate that, for a given charge level, the 7-term exponential fault model results in a higher chance of having a latch error. More importantly, different latch-error patterns are captured from the target circuits under the new fault model.

Yuan, Xuejun

1996-01-01T23:59:59.000Z

279

Combustion oscillation control by cyclic fuel injection  

SciTech Connect

A number of recent articles have demonstrated the use of active control to mitigate the effects of combustion instability in afterburner and dump combustor applications. In these applications, cyclic injection of small quantities of control fuel has been proposed to counteract the periodic heat release that contributes to undesired pressure oscillations. This same technique may also be useful to mitigate oscillations in gas turbine combustors, especially in test rig combustors characterized by acoustic modes that do not exist in the final engine configuration. To address this issue, the present paper reports on active control of a subscale, atmospheric pressure nozzle/combustor arrangement. The fuel is natural gas. Cyclic injection of 14% control fuel in a premix fuel nozzle is shown to reduce oscillating pressure amplitude by a factor of 0.30 (i.e., {approximately}10 dB) at 300 Hz. Measurement of the oscillating heat release is also reported.

Richards, G.A.; Yip, M.J. [USDOE Morgantown Energy Technology Center, WV (United States); Robey, E. [EG& G Technical Services of West Virginia, Morgantown Energy Technology Center, WV (United States); Cowell, L.; Rawlins, D. [Solar Turbines, Inc., San Diedgo, CA (United States)

1995-04-01T23:59:59.000Z

280

Thrombin Injection for Acute Hemorrhage Following Angiography  

SciTech Connect

Femoral arterial puncture is the main access for diagnostic and therapeutic intervention in vascular disease. Significant complications are unusual and include uncontrolled bleeding which usually requires surgery. We report the use of ultrasound-guided thrombin injection that prevented any immediate need for surgery in 2 cases of uncontrolled bleeding following femoral arteriography. Clinical presentations and treatment are reported, together with a review of the literature.

Richards, T., E-mail: tobyrichards@btinternet.com; Mussai, F. J.; Phillips-Hughes, J.; Uberoi, R.; Boardman, P. [John Radcliffe Hospital, Nuffield Department of Surgery and Department of Radiology (United Kingdom)

2007-07-15T23:59:59.000Z

Note: This page contains sample records for the topic "injection dsi systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Stanford Geothermal Program, reservoir and injection technology  

DOE Green Energy (OSTI)

This annual report of the Stanford Geothermal Program presents major projects in reservoir and injection technology. The four include: (1) an application of the boundary element method to front tracking and pressure transient testing; (2) determination of fracture aperture, a multi-tracer approach; (3) an analysis of tracer and thermal transients during reinjection; and, (4) pressure transient modeling of a non-uniformly fractured reservoir. (BN)

Horne, R.; Ramey, H.J. Jr.; Miller, F.G.; Brigham, W.E.; Kruger, P.

1988-12-01T23:59:59.000Z

282

Injection engine as a control object. I. Schematic diagram of the engine and synthesis of a mathematical model  

Science Conference Proceedings (OSTI)

The paper is devoted to the analysis of injection engine as an object of automatic control by a built-in microprocessor system. The schematic diagram of the engine is presented; controlled, measured, and input variables are indicated; a mathematical ...

D. N. Gerasimov; H. Javaherian; D. V. Efimov; V. O. Nikiforov

2010-10-01T23:59:59.000Z

283

A model comparison initiative for a CO2 injection field test: An introduction to Sim-SEQ  

E-Print Network (OSTI)

of a multiphase water–oil– CO 2 system using a water–CO 2et al. , 2011) in a depleted oil and gas reservoir under COwith CO 2 injected into the oil-bearing zone in the northern

Mukhopadhyay, S.

2013-01-01T23:59:59.000Z

284

European Lean Gasoline Direct Injection Vehicle Benchmark  

DOE Green Energy (OSTI)

Lean Gasoline Direct Injection (LGDI) combustion is a promising technical path for achieving significant improvements in fuel efficiency while meeting future emissions requirements. Though Stoichiometric Gasoline Direct Injection (SGDI) technology is commercially available in a few vehicles on the American market, LGDI vehicles are not, but can be found in Europe. Oak Ridge National Laboratory (ORNL) obtained a European BMW 1-series fitted with a 2.0l LGDI engine. The vehicle was instrumented and commissioned on a chassis dynamometer. The engine and after-treatment performance and emissions were characterized over US drive cycles (Federal Test Procedure (FTP), the Highway Fuel Economy Test (HFET), and US06 Supplemental Federal Test Procedure (US06)) and steady state mappings. The vehicle micro hybrid features (engine stop-start and intelligent alternator) were benchmarked as well during the course of that study. The data was analyzed to quantify the benefits and drawbacks of the lean gasoline direct injection and micro hybrid technologies from a fuel economy and emissions perspectives with respect to the US market. Additionally that data will be formatted to develop, substantiate, and exercise vehicle simulations with conventional and advanced powertrains.

Chambon, Paul H [ORNL; Huff, Shean P [ORNL; Edwards, Kevin Dean [ORNL; Norman, Kevin M [ORNL; Prikhodko, Vitaly Y [ORNL; Thomas, John F [ORNL

2011-01-01T23:59:59.000Z

285

Geothermal injection technology program. Annual progress report, FY-85  

DOE Green Energy (OSTI)

This report summarizes injection research conducted during FY-1985. The objective was to develop a better understanding of the migration and impact of fluids injected in geothermal reservoirs. Separate abstracts have been prepared for individual project summaries. (ACR)

Not Available

1986-02-01T23:59:59.000Z

286

NETL: News Release - CO2 Injection Begins in Illinois  

NLE Websites -- All DOE Office Websites (Extended Search)

21, 2011 CO2 Injection Begins in Illinois Large-Scale Test to Inject 1 Million Metric Tons of Carbon Dioxide in Saline Formation Washington, D.C. - The Midwest Geological...

287

On the production behavior of enhanced geothermal systems with CO2 as working fluid  

E-Print Network (OSTI)

temperature pressure Production/Injection pattern area (Fig.injection pressure (downhole) production pressure (downhole)On the Production Behavior of Enhanced Geothermal Systems

Pruess, K.

2008-01-01T23:59:59.000Z

288

OPTIMIZATION OF INJECTION INTO VAPOR-DOMINATED GEOTHERMAL  

E-Print Network (OSTI)

. ................................... 19 FIGURE 3.13: ONE-DIMENSIONAL MODEL WITH A PAIR OF INJECTION AND PRODUCTION WELLS. ................... 20 FIGURE 3.14: TWO-DIMENSIONAL MODEL WITH PRODUCTION AND INJECTION WELLS AT THE CENTER.......... 20 and an injection well was placed in the corner diagonally opposite. The maximum production rate of the well

Stanford University

289

Sample extraction and injection with a microscale preconcentrator.  

SciTech Connect

This report details the development of a microfabricated preconcentrator that functions as a fully integrated chemical extractor-injector for a microscale gas chromatograph (GC). The device enables parts-per-billion detection and quantitative analysis of volatile organic compounds (VOCs) in indoor air with size and power advantages over macro-scale systems. The 44 mm{sup 3} preconcentrator extracts VOCs using highly adsorptive, granular forms of graphitized carbon black and carbon molecular sieves. The micron-sized silicon cavities have integrated heating and temperature sensing allowing low power, yet rapid heating to thermally desorb the collected VOCs (GC injection). The keys to device construction are a new adsorbent-solvent filling technique and solvent-tolerant wafer-level silicon-gold eutectic bonding technology. The product is the first granular adsorbent preconcentrator integrated at the wafer level. Other advantages include exhaustive VOC extraction and injection peak widths an order of magnitude narrower than predecessor prototypes. A mass transfer model, the first for any microscale preconcentrator, is developed to describe both adsorption and desorption behaviors. The physically intuitive model uses implicit and explicit finite differences to numerically solve the required partial differential equations. The model is applied to the adsorption and desorption of decane at various concentrations to extract Langmuir adsorption isotherm parameters from effluent curve measurements where properties are unknown a priori.

Robinson, Alex Lockwood (Advanced Sensor Technologies, Albuquerque, NM); Chan, Helena Kai Lun

2007-09-01T23:59:59.000Z

290

LASER WAKEFIELD ACCELERATION BEYOND 1 GeV USING IONIZATION INDUCED INJECTION*  

Science Conference Proceedings (OSTI)

A series of laser wake field accelerator experiments leading to electron energy exceeding 1 GeV are described. Theoretical concepts and experimental methods developed while conducting experiments using the 10 TW Ti:Sapphire laser at UCLA were implemented and transferred successfully to the 100 TW Callisto Laser System at the Jupiter Laser Facility at LLNL. To reach electron energies greater than 1 GeV with current laser systems, it is necessary to inject and trap electrons into the wake and to guide the laser for more than 1 cm of plasma. Using the 10 TW laser, the physics of self-guiding and the limitations in regards to pump depletion over cm-scale plasmas were demonstrated. Furthermore, a novel injection mechanism was explored which allows injection by ionization at conditions necessary for generating electron energies greater than a GeV. The 10 TW results were followed by self-guiding at the 100 TW scale over cm plasma lengths. The energy of the self-injected electrons, at 3 x 10{sup 18} cm{sup -3} plasma density, was limited by dephasing to 720 MeV. Implementation of ionization injection allowed extending the acceleration well beyond a centimeter and 1.4 GeV electrons were measured.

Marsh, K A; Clayton, C E; Joshi, C; Lu, W; Mori, W B; Pak, A; silva, L O; Lemos, N; Fonseca, R A; de Freitas, S; Albert, F; Doeppner, T; Filip, C; Froula, D; Glenzer, S H; Price, D; Ralph, J; Pollock, B B

2011-03-22T23:59:59.000Z

291

Projective Space Codes for the Injection Metric  

E-Print Network (OSTI)

In the context of error control in random linear network coding, it is useful to construct codes that comprise well-separated collections of subspaces of a vector space over a finite field. In this paper, the metric used is the so-called "injection distance", introduced by Silva and Kschischang. A Gilbert-Varshamov bound for such codes is derived. Using the code-construction framework of Etzion and Silberstein, new non-constant-dimension codes are constructed; these codes contain more codewords than comparable codes designed for the subspace metric.

Khaleghi, Azadeh

2009-01-01T23:59:59.000Z

292

Nonisothermal injection tests in fractured reservoirs  

DOE Green Energy (OSTI)

The paper extends the analysis of nonisothermal pressure transient data to fractured reservoirs. Two cases are considered: reservoirs with predominantly horzontal fractures and reservoirs with predominantly vertical fractures. Effects of conductive heat transfer between the fractures and the rock matrix are modeled, and the resulting pressure transients evaluated. Thermal conduction tends to retard the movement of the thermal front in the fractures, which significantly affects the pressure transient data. The purpose of the numerical simulation studies is to provide methods for analyzing nonisothermal injection/falloff data for fractured reservoirs.

Cox, B.L.; Bodvarsson, G.S.

1985-01-01T23:59:59.000Z

293

Predicting the spatial extent of injection-induced zones of enhanced permeability at the Northwest Geysers EGS Demonstration Project  

SciTech Connect

We present the results of coupled thermal, hydraulic, and mechanical (THM) modeling of a proposed stimulation injection associated with an Enhanced Geothermal System (EGS) demonstration project at the northwest part of The Geysers geothermal field, California. The project aims at creating an EGS by directly and systematically injecting cool water at relatively low pressure into a known High Temperature (about 280 to 350 C) Zone (HTZ) located under the conventional (240 C) steam reservoir at depths below 3 km. Accurate micro-earthquake monitoring from the start of the injection will be used as a tool for tracking the development of the EGS. We first analyzed historic injection and micro-earthquake data from an injection well (Aidlin 11), located about 3 miles to the west of the new EGS demonstration area. Thereafter, we used the same modeling approach to predict the likely extent of the zone of enhanced permeability for a proposed initial injection in two wells (Prati State 31 and Prati 32) at the new EGS demonstration area. Our modeling indicates that the proposed injection scheme will provide additional steam production in the area by creating a zone of permeability enhancement extending about 0.5 km from each injection well which will connect to the overlying conventional steam reservoir.

Rutqvist, J.; Oldenburg, C.M.; Dobson, P.F.

2010-02-01T23:59:59.000Z

294

A CONCEPTUAL DESIGN FOR THE ZEPHYR NEUTRAL BEAM INJECTION SYSTEM  

E-Print Network (OSTI)

The isolation transformer receives its power from a 380 V, 3power supply impedance by a combination of higher transformersources. Power line; 110 k V ; 5 0 H z , 3 phase Transformer

Cooper, W.S.

2010-01-01T23:59:59.000Z

295

A CONCEPTUAL DESIGN FOR THE ZEPHYR NEUTRAL BEAM INJECTION SYSTEM  

E-Print Network (OSTI)

accel PS, the current-voltage requirements are based on theconstancy L8L requirement Maximum output voltage drop forfraction, voltage, gas, pulse length) Other requirements (

Cooper, W.S.

2010-01-01T23:59:59.000Z

296

A CONCEPTUAL DESIGN FOR THE ZEPHYR NEUTRAL BEAM INJECTION SYSTEM  

E-Print Network (OSTI)

difficulties in using Cubes as HVDC series switches promptedwere developed as series HVDC switches* have provenapproach, even in large HVDC applications. We note that the

Cooper, W.S.

2010-01-01T23:59:59.000Z

297

A CONCEPTUAL DESIGN FOR THE ZEPHYR NEUTRAL BEAM INJECTION SYSTEM  

E-Print Network (OSTI)

time needed to perfect remote handling capability and toShielding 2.0.1.3 Remote Handling 2.0.1.4 Source Layoutto them by cranes and remote handling equipment; we would

Cooper, W.S.

2010-01-01T23:59:59.000Z

298

Supersonic Jet Excitation using Flapping Injection  

E-Print Network (OSTI)

Supersonic jet noise reduction is important for high speed military aircraft. Lower acoustic levels would reduce structural fatigue leading to longer lifetime of the jet aircraft. It is not solely structural aspects which are of importance, health issues of the pilot and the airfield per- sonnel are also very important, as high acoustic levels may result in severe hearing damage. It remains a major challenge to reduce the overall noise levels of the aircraft, where the supersonic exhaust is the main noise source for near ground operation. Fluidic injection into the supersonic jet at the nozzle exhaust has been shown as a promising method for noise reduction. It has been shown to speed up the mix- ing process of the main jet, hence reducing the kinetic energy level of the jet and the power of the total acoustic radiation. Furthermore, the interaction mechanism between the fluidic injection and the shock structure in the jet exhaust plays a crucial role in the total noise radia- tion. In this study, LES is used...

Hafsteinsson, Haukur; Andersson, Niklas; Cuppoletti, Daniel; Gutmark, Ephraim; Prisell, Erik

2013-01-01T23:59:59.000Z

299

Analysis of thermally induced permeability enhancement in geothermal injection wells  

DOE Green Energy (OSTI)

Reinjection of spent geothermal brine is a common means of disposing of geothermal effluents and maintaining reservoir pressures. Contrary to the predictions of two-fluid models (two-viscosity) of nonisothermal injection, an increase of injectivity, with continued injection, is often observed. Injectivity enhancement and thermally-affected pressure transients are particularly apparent in short-term injection tests at the Los Azufres Geothermal Field, Mexico. During an injection test, it is not uncommon to observe that after an initial pressure increase, the pressure decreases with time. As this typically occurs far below the pressure at which hydraulic fracturing is expected, some other mechanism for increasing the near-bore permeability must explain the observed behavior. This paper focuses on calculating the magnitude of the nearbore permeability changes observed in several nonisothermal injection tests conducted at the Los Azufres Geothermal Field.

Benson, S.M.; Daggett, J.S.; Iglesias, E.; Arellano, V.; Ortiz-Ramirez, J.

1987-02-01T23:59:59.000Z

300

On False Data Injection Attacks against Distributed Energy Routing in Smart Grid  

Science Conference Proceedings (OSTI)

Smart Grid is a new type of energy-based cyber physical system (CPS) that will provide reliable, secure, and efficient energy transmission and distribution. The way to secure the distributed energy routing process that efficiently utilizes the distributed ... Keywords: Smart grid, Distributed energy routing, False data injection attacks, Energy distribution

Jie Lin; Wei Yu; Xinyu Yang; Guobin Xu; Wei Zhao

2012-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "injection dsi systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

The Impact of Injection on Seismicity at The Geyses, California Geothermal Field  

E-Print Network (OSTI)

of thermoelastic stress on injection well fracturing. SPE38N) LBNL NCSN POWER PLANTS INJECTION WELLS EVENTS LBNLNCSN POWER PLANTS INJECTION WELLS EVENTS Aidlin 11 - LBNL

Majer, Ernest L.; Peterson, John E.

2008-01-01T23:59:59.000Z

302

The Design and Development of An Externally Fired Steam Injected Gas Turbine for Cogeneration  

E-Print Network (OSTI)

This paper describes the theoretical background and the design and development of a prototype externally fired steam injected (ECSI) gas turbine which has a potential to utilize lower grade fuels. The system is designed around a 2 shaft 360 HP gas turbine. Several modifications to the gas turbine (Brayton Cycle) and the effects of cycle parameters such as pressure ratio and turbine inlet temperature are discussed. Steams injected cycles are examined and the concept of the ECSI gas turbine is introduced. The discussion includes criteria for selecting a suitable heat exchanger and considerations for start-up cycles. The feasibility of the concept and discussion of problem areas in the prototype are discussed.

Boyce, M. P.; Meher-Homji, C.; Ford, D.

1981-01-01T23:59:59.000Z

303

Determination of Zinc-Based Additives in Lubricating Oils by Flow-Injection Analysis with Flame-AAS Detection Exploiting Injection with a Computer-Controlled Syringe  

E-Print Network (OSTI)

A flow-injection system is proposed for the determination of metal-based additives in lubricating oils. The system, operating under computer control uses a motorised syringe for measuring and injecting the oil sample (200 µL) in a kerosene stream, where it is dispersed by means of a packed mixing reactor and carried to an atomic absorption spectrometer which is used as detector. Zinc was used as model analyte. Two different systems were evaluated, one for low concentrations (range 0–10 ppm) and the second capable of providing higher dilution rates for high concentrations (range 0.02%–0.2 % w/w). The sampling frequency was about 30 samples/h. Calibration curves fitted a second-degree regression model (r 2 = 0.996). Commercial samples with high and low zinc levels were analysed by the proposed method and the results were compared with those obtained with the standard ASTM method. The t test for mean values showed no significant differences at the 95 % confidence level. Precision (RSD%) was better than 5 % (2 % typical) for the high concentrations system. The carryover between successive injections was found to be negligible. 1.

Gustavo Pignalosa; Moisés Knochen; Noel Cabrera

2004-01-01T23:59:59.000Z

304

Parametric performance analysis of steam-injected gas turbine with a thermionic-energy-converter-lined combustor  

SciTech Connect

The performance of steam-injected gas turbines having combustors lined with thermionic energy converters (STIG/TEC systems) was analyzed and compared with that of two baseline systems a steam-injected gas turbine (without a TEC-lined combustor) and a conventional combined gas turbine/steam turbine cycle. Common gas turbine parameters were assumed for all of the systems. Two configurations of the STIG/TEC system were investigated. In both cases, steam produced in an exhaust-heat-recovery boiler cools the TEC collectors. It is then injected into the gas combustion stream and expanded through the gas turbine. The STIG/TEC system combines the advantage of gas turbine steam injection with the conversion of high-temperature combustion heat by TEC's. The addition of TEC's to the baseline steam-injected gas turbine improves both its efficiency and specific power. Depending on system configuration and design parameters, the STIG/TEC system can also achieve higher efficiency and specific power than the baseline combined cycle.

Choo, Y.K.; Burns, R.K.

1982-02-01T23:59:59.000Z

305

Method for improving the steam splits in a multiple steam injection process using multiple steam headers  

SciTech Connect

This patent describes a method for enhancing the uniformity of steam distribution in a multiple steam injection system comprising a steam generator, a primary steam header, at least one secondary steam header, a primary steam line connecting the generator to the primary header, at lease one secondary steam line connecting the primary header to the secondary steam header, and a plurality of tertiary steam lines connecting the secondary steam header to a plurality of stem injection wells. It comprises injecting a surfactant into the primary steam line, mixing the surfactant and steam in the primary steam line sufficiently so that the surfactant and the steam enter the primary steam header as a foam, and mixing the surfactant and steam in the secondary steam lines sufficiently so that the surfactant and the steam enter the secondary steam header as a foam.

Stowe, G.R.

1991-03-19T23:59:59.000Z

306

U-157: Ruby Mail Gem Directory Traversal and Shell Command Injection  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

57: Ruby Mail Gem Directory Traversal and Shell Command 57: Ruby Mail Gem Directory Traversal and Shell Command Injection Vulnerabilities U-157: Ruby Mail Gem Directory Traversal and Shell Command Injection Vulnerabilities April 27, 2012 - 7:00am Addthis PROBLEM: Ruby Mail Gem Directory Traversal and Shell Command Injection Vulnerabilities PLATFORM: Mail gem for Ruby 2.x ABSTRACT: Some vulnerabilities have been reported in the Mail gem for Ruby, which can be exploited by malicious people to manipulate certain data and compromise a vulnerable system. Reference Links: Secunia Advisory SA48970 CVE-2012-2139 CVE-2012-2140 IMPACT ASSESSMENT: Medium Discussion: Input passed via the "to" parameter within the file delivery method is not properly verified before being used and can be exploited to modify arbitrary files via directory traversal attacks. Certain input passed to

307

U-026: Cisco Small Business SRP500 Series Bug Lets Remote Users Inject  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

6: Cisco Small Business SRP500 Series Bug Lets Remote Users 6: Cisco Small Business SRP500 Series Bug Lets Remote Users Inject Commands U-026: Cisco Small Business SRP500 Series Bug Lets Remote Users Inject Commands November 3, 2011 - 8:15am Addthis PROBLEM: Cisco Small Business SRP500 Series Bug Lets Remote Users Inject Commands. PLATFORM: The following models are affected when running firmware prior to version 1.1.24: Cisco SRP521W Cisco SRP526W Cisco SRP527W The following models are affected when running firmware prior to version 1.2.1: Cisco SRP541W Cisco SRP546W Cisco SRP547W ABSTRACT: A remote user can create a URL that, when loaded by the target authenticated administrative user, will execute arbitrary commands on the target system. reference LINKS: Advisory ID: cisco-sa-20111102-srp500 SecurityTracker Alert ID: 1026266

308

Pilot-scale HCl control by dry alkaline injection for emissions from refuse incinerators. Technical report  

Science Conference Proceedings (OSTI)

One method of removing the HCl in an exhaust-gas stream is to directly inject finely divided sorbent particles into the gas stream upstream from particulate collection equipment, allowing enough time for the HCl to react with the sorbent in the duct. The study proposed to provide data on HCl removal from a simulated incinerator exhaust stream as a function of the in-duct reaction/residence time, the reaction temperature, and the sorbent-to-gas ratio. A 500-acfm pilot-scale HCl control system utilizing dry powdered sorbent was tested at the University of Washington. Powdered alkaline reagents including sodium bicarbonate and calcium hydroxide were injected into boiler flue gas spiked with hydrogen chloride gas. The acid gas reacts with the injected sorbent in a 20-inch diameter by 26-foot high vertical, down-flow vessel. HCl removal efficiency was measured as a function of sorbent stoichiometry, gas residence time in reactor, and reaction temperature.

Moore, D.; Pilat, M.

1988-11-08T23:59:59.000Z

309

Top-Off Injection and Higher Currents at the Stanford Synchrotron Radiation Lightsource  

Science Conference Proceedings (OSTI)

The Stanford Synchrotron Radiation Lightsource (SSRL) at the SLAC National Accelerator Laboratory is a 234 m circumference storage ring for 3 GeV electrons with its synchrotron radiation serving currently 13 beamlines with about 27 experimental stations. It operated for long time with 100 mA peak current provided by usually three injections per day. In July 2009, the maximum beam current was raised to 200 mA. Over the period from June 2009 to March 2010, Top-Off operation started at every beamline. Top-Off, i.e., the injection of electrons into the storage ring with injection stoppers open, is necessary for SSRL to reach its design current of 500 mA. In the future, the maximal power of the injection current will also soon be raised from currently 1.5 W to 5 W. The Radiation Protection Department at SLAC worked with SSRL on the specifications for the safety systems for operation with Top-Off injection and higher beam currents.

Bauer, Johannes

2011-04-05T23:59:59.000Z

310

GAS INJECTION/WELL STIMULATION PROJECT  

SciTech Connect

Driver Production proposes to conduct a gas repressurization/well stimulation project on a six well, 80-acre portion of the Dutcher Sand of the East Edna Field, Okmulgee County, Oklahoma. The site has been location of previous successful flue gas injection demonstration but due to changing economic and sales conditions, finds new opportunities to use associated natural gas that is currently being vented to the atmosphere to repressurize the reservoir to produce additional oil. The established infrastructure and known geological conditions should allow quick startup and much lower operating costs than flue gas. Lessons learned from the previous project, the lessons learned form cyclical oil prices and from other operators in the area will be applied. Technology transfer of the lessons learned from both projects could be applied by other small independent operators.

John K. Godwin

2005-12-01T23:59:59.000Z

311

New type gas-injection plant readied  

SciTech Connect

A unique gas-injection plant is about to go on stream in Venezuela's Lake Maracaibo. The $10-million installation, designed for unattended operation, is a joint venture of Phillips Petroleum Co., as operator for itself, and Cia. Shell de Venezuela. The plant, housed on a 120 by 130-ft platform, will be the first in the world to use gas turbines to drive reciprocating compressors. The 130 MMscfd facility will use 2 General Electric 15,000-hp gas turbines with gear reducers to drive a pair of 4-stage Cooper- Bessemer LM-8 compressors. No previous attempt has ever been made to drive this type of unit by gas turbines. Phillips says the gas turbines were selected because of inherent flexibility reliability as prime movers, and lack of vibration--an important advantage in offshore gas plants.

Franco, A.

1967-07-17T23:59:59.000Z

312

Current drive, anticurrent drive, and balanced injection  

SciTech Connect

In lower hybrid (LH) discharges, the number of suprathermal electrons is limited by the upper bound on the current density from the q = 1 condition, which is caused by the onset of the m = 1 MHD instability. The stored energy of suprathermal electrons, measured in terms of a poloidal beta, scales with plasma current as I/sub p//sup -1/. Potentially, these bounds represent very restrictive conditions for heating in larger machines. Consequently, it seems necessary to perform experiments where the electrons are driven in both directions, parallel and antiparallel to the magnetic field, i.e., bidirectional scenarios like anticurrent drive or balanced injection. Data from PLT relevant to these ideas are discussed. 6 refs., 4 figs.

von Goeler, S.; Stevens, J.; Beiersdorfer, P.; Bell, R.; Bernabei, S.; Bitter, M.; Cavallo, A.; Chu, T.K.; Fishman, H.; Hill, K.

1987-08-01T23:59:59.000Z

313

Recycling plastic scrap: Injection molding. (Latest citations from the Rubber and Plastics Research Association database). Published Search  

Science Conference Proceedings (OSTI)

The bibliography contains citations concerning the recycling of scrap plastic produced in the injection molding process. Plastic pellets made from scrap, that are used in the injection molding process, are also discussed. Recycling equipment and automated recycling systems are described. The reuse of plastic scrap culled from junk automobiles and packaging materials is discussed, and waste byproducts from polyurethane production are described. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

NONE

1997-02-01T23:59:59.000Z

314

Recycling plastic scrap: Injection molding. (Latest citations from the Rubber and Plastics Research Association database). Published Search  

Science Conference Proceedings (OSTI)

The bibliography contains citations concerning the recycling of scrap plastic produced in the injection molding process. Plastic pellets made from scrap, that are used in the injection molding process, are also discussed. Recycling equipment and automated recycling systems are described. The reuse of plastic scrap culled from junk automobiles and packaging materials is discussed, and waste byproducts from polyurethane production are described. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

NONE

1996-04-01T23:59:59.000Z

315

Recycling plastic scrap: Injection molding. (Latest citations from the Rubber and Plastics Research Association database). Published Search  

Science Conference Proceedings (OSTI)

The bibliography contains citations concerning the recycling of scrap plastic produced in the injection molding process. Plastic pellets made from scrap, that are used in the injection molding process, are also discussed. Recycling equipment and automated recycling systems are described. The reuse of plastic scrap culled from junk automobiles and packaging materials is discussed, and waste byproducts from polyurethane production are described. (Contains a minimum of 80 citations and includes a subject term index and title list.)

Not Available

1994-05-01T23:59:59.000Z

316

Recycling plastic scrap: Injection molding. (Latest citations from the Rubber and Plastics Research Association database). Published Search  

Science Conference Proceedings (OSTI)

The bibliography contains citations concerning the recycling of scrap plastic produced in the injection molding process. Plastic pellets made from scrap, that are used in the injection molding process, are also discussed. Recycling equipment and automated recycling systems are described. The reuse of plastic scrap culled from junk automobiles and packaging materials is discussed, and waste byproducts from polyurethane production are described. (Contains a minimum of 88 citations and includes a subject term index and title list.)

NONE

1995-01-01T23:59:59.000Z

317

Evaluation of Sorbent Injection for Mercury Control  

Science Conference Proceedings (OSTI)

The power industry in the U.S. is faced with meeting new regulations to reduce the emissions of mercury compounds from coal-fired plants. These regulations are directed at the existing fleet of nearly 1,100 boilers. These plants are relatively old with an average age of over 40 years. Although most of these units are capable of operating for many additional years, there is a desire to minimize large capital expenditures because of the reduced (and unknown) remaining life of the plant to amortize the project. Injecting a sorbent such as powdered activated carbon into the flue gas represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. This is the final site report for tests conducted at Laramie River Station Unit 3, one of five sites evaluated in this DOE/NETL program. The overall objective of the test program is to evaluate the capabilities of activated carbon injection at five plants: Sunflower Electric's Holcomb Station Unit 1, AmerenUE's Meramec Station Unit 2, Missouri Basin Power Project's Laramie River Station Unit 3, Detroit Edison's Monroe Power Plant Unit 4, and AEP's Conesville Station Unit 6. These plants have configurations that together represent 78% of the existing coal-fired generation plants. The goals for the program established by DOE/NETL are to reduce the uncontrolled mercury emissions by 50 to 70% at a cost 25 to 50% lower than the benchmark established by DOE of $60,000/lb mercury removed. The goals of the program were exceeded at Laramie River Station by achieving over 90% mercury removal at a sorbent cost of $3,980/lb ($660/oz) mercury removed for a coal mercury content of 7.9 lb/TBtu.

Sharon Sjostrom

2005-12-30T23:59:59.000Z

318

Enhancing the use of coals by gas reburning-sorbent injection. Volume 3, Gas reburning-sorbent injection at Edwards Unit 1, Central Illinois Light Company  

Science Conference Proceedings (OSTI)

Design work has been completed for a Gas Reburning-Sorbent Injection (GR-SI) system to reduce emissions of NO{sub x}, and SO{sub 2} from a wall fired unit. A GR-SI system was designed for Central Illinois Light Company`s Edwards Station Unit 1, located in Bartonville, Illinois. The unit is rated at 117 MW(e) (net) and is front wall fired with a pulverized bituminous coal blend. The goal of the project was to reduce emissions of NO{sub x} by 60%, from the ``as found`` baseline of 0.98 lb/MBtu (420 mg/MJ), and to reduce emissions of S0{sub 2} by 50%. Since the unit currently fires a blend of high sulfur Illinois coal and low sulfur Kentucky coal to meet an S0{sub 2} limit Of 1.8 lb/MBtu (770 mg/MJ), the goal at this site was amended to meeting this limit while increasing the fraction of high sulfur coal to 57% from the current 15% level. GR-SI requires injection of natural gas into the furnace at the level of the top burner row, creating a fuel-rich zone in which NO{sub x} formed in the coal zone is reduced to N{sub 2}. The design natural gas input corresponds to 18% of the total heat input. Burnout (overfire) air is injected at a higher elevation to burn out fuel combustible matter at a normal excess air level of 18%. Recycled flue gas is used to increase the reburning fuel jet momentum, resulting in enhanced mixing. Recycled flue gas is also used to cool the top row of burners which would not be in service during GR operation. Dry hydrated lime sorbent is injected into the upper furnace to react with S0{sub 2}, forming solid CaSO{sub 4} and CaSO{sub 3}, which are collected by the ESP. The SI system design was optimized with respect to gas temperature, injection air flow rate, and sorbent dispersion. Sorbent injection air flow is equal to 3% of the combustion air. The design includes modifications of the ESP, sootblowing, and ash handling systems.

NONE

1994-10-01T23:59:59.000Z

319

Arkansas Underground Injection Control Code (Arkansas) | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Arkansas Underground Injection Control Code (Arkansas) Arkansas Underground Injection Control Code (Arkansas) Arkansas Underground Injection Control Code (Arkansas) < Back Eligibility Commercial Construction Industrial Utility Program Info State Arkansas Program Type Environmental Regulations Siting and Permitting Provider Department of Environmental Quality The Arkansas Underground Injection Control Code (UIC code) is adopted pursuant to the provisions of the Arkansas Water and Air Pollution Control Act (Arkansas Code Annotated 8-5-11). It is the purpose of this UIC Code to adopt underground injection control (UIC) regulations necessary to qualify the State of Arkansas to retain authorization for its Underground Injection Control Program pursuant to the Safe Drinking Water Act of 1974, as amended; 42 USC 300f et seq. In order

320

Injectivity Test At Raft River Geothermal Area (1979) | Open Energy  

Open Energy Info (EERE)

Injectivity Test At Raft River Geothermal Area (1979) Injectivity Test At Raft River Geothermal Area (1979) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Injectivity Test At Raft River Geothermal Area (1979) Exploration Activity Details Location Raft River Geothermal Area Exploration Technique Injectivity Test Activity Date 1979 Usefulness useful DOE-funding Unknown Notes Quantification of the pressure response prior to 600 minutes is not always possible. Short-duration (< 24-hour) injection or pump tests are conducted with the drilling rig equipment, and long-duration (21-day) injection and pump tests are then conducted with the permanent pumping facilities. References Allman, D. W.; Goldman, D.; Niemi, W. L. (1 January 1979) Evaluation of testing and reservoir parameters in geothermal wells at Raft

Note: This page contains sample records for the topic "injection dsi systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

T-731:Symantec IM Manager Code Injection Vulnerability | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

T-731:Symantec IM Manager Code Injection Vulnerability T-731:Symantec IM Manager Code Injection Vulnerability T-731:Symantec IM Manager Code Injection Vulnerability September 30, 2011 - 8:30am Addthis PROBLEM: Symantec IM Manager Code Injection Vulnerability. PLATFORM: IM Manager versions prior to 8.4.18 are affected. ABSTRACT: Symantec IM Manager is prone to a vulnerability that will let attackers run arbitrary code. referecnce LINKS: Symantec Security Advisory SYM11-012 Symantec Security Updates Bugtraq ID: 49742 IMPACT ASSESSMENT: High Discussion: Symantec was notified of Cross-Site Scripting and Code injection/execution issues present in the Symantec IM Manager management console. The management console fails to properly filter/validate external inputs. Successful exploitation of SQL Injection or Remote Code execution might

322

New Pellet Injection Schemes on DIII-D* S. K. Combs, L. R. Baylor, C. R. Foust, and T. C. Jernigan  

E-Print Network (OSTI)

the curved guide tubes is limited (·200 m/s for HFS injection schemes). Thus, one of the three gas guns are subjected to stresses from centrifugal and impact forces in the curved tubes, and the speed at which intact INJECTION SYSTEM While the injector used on ASDEX-Upgrade is a centrifuge [3], the DIII-D injector

323

The Impact of Injection on Seismicity at The Geyses, California Geothermal Field  

E-Print Network (OSTI)

have been injecting steam condensate, local rain and streamhave been injecting steam condensate, local rain and stream

Majer, Ernest L.; Peterson, John E.

2008-01-01T23:59:59.000Z

324

Coal combustion under conditions of blast furnace injection. Final technical report, September 1, 1992--August 31, 1993  

Science Conference Proceedings (OSTI)

A potentially new use for Illinois coal is as a fuel injected into a blast furnace to produce molten iron as the first step in steel production. Because of its increasing cost and decreasing availability, metallurgical coke is now being replaced by coal injected at the tuyere area of the furnace where the blast air enters. The purpose of this study is to evaluate the combustion of coal during the blast furnace injection process and to delineate the optimum properties of the feed coal. This investigation is significant to the use of Illinois coal in that the limited research to date suggests that coals of low fluidity and moderate to high sulfur and chlorine contents are suitable feedstocks for blast furnace injection. During the first phase of this project a number of the objectives were realized, specifically: (1) a blast furnace sampling system was developed and used successfully to collect samples inside an active furnace; (2) two sets of blast furnace samples were collected and petrographic analysis showed that char derived from injected coal is entering the reduction zone of the furnace; (3) a coal/char sampling probe was designed and fabricated; (4) the completion of a program of reactivity experiments on the injected coal char, blast furnace coke and Herrin No. 6 char. The results of the reactivity experiments indicate that Herrin No. 6 coal is similar or even superior to coals now being used in blast furnace injection and that additional testing is warranted.

Crelling, J.C. [Southern Illinois Univ., Carbondale, IL (United States). Dept. of Geology; Case, E.R. [Armco, Inc., Middletown, OH (United States). Research and Technology Div.

1993-12-31T23:59:59.000Z

325

INTENSITY OF BETATRON RADIATION AS FUNCTION OF INJECTION VOLTAGE  

SciTech Connect

The intensity of betatron radiation emission as a function of injection voltage was studied using a 25-Mev betatron with a 350-kw external electron injector. The injection voltage was measured every 20 to 30 kw from 50 to 250 kw. The results showed that up to 250 kw, emission intensity increases according to theory. It is suggested that an increase in injection intensity up to 1000 kw and over should result in a considerable rise in emission intensity. (R.V.J.)

Moskalev, V.A.; Okulov, B.V.

1962-09-01T23:59:59.000Z

326

Numerical modeling of injection experiments at The Geysers  

DOE Green Energy (OSTI)

Data from injection experiments in the southeast Geysers are presented that show strong interference (both negative and positive) with a neighboring production well. Conceptual and numerical models are developed that explain the negative interference (decline of production rate) in terms of heat transfer limitations and water-vapor relative permeability effects. Recovery and over-recovery following injection shut-in are attributed to boiling of injected fluid, with heat of vaporization provided by the reservoir rocks.

Pruess, K. [Lawrence Berkeley Lab., CA (United States); Enedy, S. [Northern California Power Agency, Middletown, CA (United States)

1993-01-01T23:59:59.000Z

327

Method for controlling corrosion in thermal vapor injection gases  

DOE Patents (OSTI)

An improvement in the method for producing high pressure thermal vapor streams from combustion gases for injection into subterranean oil producing formations to stimulate the production of viscous minerals is described. The improvement involves controlling corrosion in such thermal vapor gases by injecting water near the flame in the combustion zone and injecting ammonia into a vapor producing vessel to contact the combustion gases exiting the combustion chamber.

Sperry, John S. (Houston, TX); Krajicek, Richard W. (Houston, TX)

1981-01-01T23:59:59.000Z

328

Experimental investigation of caustic steam injection for heavy oils  

E-Print Network (OSTI)

An experimental study has been conducted to compare the effect of steam injection and caustic steam injection in improving the recovery of San Ardo and Duri heavy oils. A 67 cm long x 7.4 cm O.D (outer diameter), steel injection cell is used in the study. Six thermocouples are placed at specific distances in the injection cell to record temperature profiles and thus the steam front velocity. The injection cell is filled with a mixture of oil, water and sand. Steam is injected at superheated conditions of 238oC with the cell outlet pressure set at 200 psig, the cell pressure similar to that found in San Ardo field. The pressure in the separators is kept at 50 psig. The separator liquid is sampled at regular intervals. The liquid is centrifuged to determine the oil and water volumes, and oil viscosity, density and recovery. Acid number measurements are made by the titration method using a pH meter and measuring the EMF values. The interfacial tensions of the oil for different concentrations of NaOH are also measured using a tensionometer. Experimental results show that for Duri oil, the addition of caustic results in an increase in recovery of oil from 52% (steam injection) to 59 % (caustic steam injection). However, caustic has little effect on San Ardo oil where oil recovery is 75% (steam injection) and 76 % (caustic steam injection). Oil production acceleration is seen with steam-caustic injection. With steam caustic injection there is also a decrease in the produced oil viscosity and density for both oils. Sodium hydroxide concentration of 1 wt % is observed to give the lowest oil-caustic interfacial tension. The acid numbers for San Ardo and Duri oil are measured as 6.2 and 3.57 respectively.

Madhavan, Rajiv

2009-05-01T23:59:59.000Z

329

Influence of water injection on performance and emissions of a direct-injection hydrogen research engine.  

DOE Green Energy (OSTI)

The application of hydrogen (H{sub 2}) as an internal combustion (IC) engine fuel has been under investigation for several decades. The favorable physical properties of hydrogen make it an excellent alternative fuel for IC engines and hence it is widely regarded as the energy carrier of the future. Direct injection of hydrogen allows optimizing this potential as it provides multiple degrees of freedom to influence the in-cylinder combustion processes and consequently engine efficiency and exhaust emissions.

Nande, A. M.; Wallner, T.; Naber, J. (Energy Systems); (MIchigan Technological Univ.)

2008-10-06T23:59:59.000Z

330

NETL: News Release - DOE Technology Monitors CO2 Injection in...  

NLE Websites -- All DOE Office Websites (Extended Search)

3, 2008 DOE Technology Monitors CO2 Injection in Australian Gas Field CSLF Project Demonstrates Unique Carbon Sequestration Technologies WASHINGTON, D.C. - Australia has launched...

331

INJECTION AND THERMAL BREAKTHROUGH IN FRACTURED GEOTHERMAL RESERVOIRS  

E-Print Network (OSTI)

and Pruess, K. , Analysis of injection testing of geothermalreservoirs: Geothermal Resoures Council, Vol. 4. , (into a fractured geothermal reservoir: Transactions, Vol. 4,

Bodvarsson, Gudmundur S.

2012-01-01T23:59:59.000Z

332

Injection Phenomena in the PS Converter - The Teachings of J ...  

Science Conference Proceedings (OSTI)

blockage and punching); the concept of “high pressure” or sonic injection including a review of the ... to the representatives of the technology suppliers as well as.

333

Injection of Alternative Carbon Containing Materials in the BF  

Science Conference Proceedings (OSTI)

By injection of the materials preparation methods in terms e.g. drying and/or ... Efficiency in recovery of valuable compounds as well as the behaviour of ...

334

Application of Metal Injection Molding to Soft Magnetic Materials  

Science Conference Proceedings (OSTI)

Advances in Current Activated Tip-Based Sintering (CATS) · Advances in Synthesis and Densification of Heterogeneous Materials · Application of Metal Injection ...

335

Study Reveals Fuel Injection Timing Impact on Particle Number...  

NLE Websites -- All DOE Office Websites (Extended Search)

In an ongoing quest to meet ever-more-rigorous fuel economy and emissions requirements, vehicle manufacturers are increasingly turning to gasoline direct injection (GDI) coupled...

336

Interpretation of self-potential measurements during injection...  

Open Energy Info (EERE)

self-potential measurements during injection tests at Raft River, Idaho. Final report Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Report: Interpretation of...

337

Single Well Injection Withdrawl Tracer Tests for Proppant ...  

A large question preventing optimal natural gas production from "hydrofracked" shales is how far proppants, injected to keep shale fractures open, ...

338

Improvement of Mechanical Properties of Injection Molded Wood  

Science Conference Proceedings (OSTI)

... by one double-gate injection mould integrated an ultrasonic generator unit. ... Polymer Based Composite and Hybrid Materials for Wind Power Generation.

339

Injectivity Test At Fenton Hill Hdr Geothermal Area (Grigsby...  

Open Energy Info (EERE)

navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Injectivity Test At Fenton Hill Hdr Geothermal Area (Grigsby, Et Al., 1983) Exploration Activity Details...

340

Resistivity measurements before and after injection Test 5 at...  

Open Energy Info (EERE)

Facebook icon Twitter icon Resistivity measurements before and after injection Test 5 at Raft River KGRA, Idaho. Final report Jump to: navigation, search GEOTHERMAL...

Note: This page contains sample records for the topic "injection dsi systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Duct injection technology prototype development: Evaluation of engineering data  

SciTech Connect

The objective of the Duct Injection Technology Prototype Development Project is to develop a sound design basis for applying duct injection technology as a post-combustion SO{sub 2}emissions control method to existing coal-fired power plants. The necessary engineering design and scale-up criteria will be developed for the commercialization of duct injection technology for the control of SO{sub 2} emissions from coal-fired boilers in the utility industry. The primary focus of the analyses summarized in this Topical Report is the review of the known technical and economic information associated with duct injection technology. (VC)

Not Available

1990-07-01T23:59:59.000Z

342

Alaska Natural Gas Injections into Underground Storage (Million...  

U.S. Energy Information Administration (EIA) Indexed Site

of Natural Gas into Underground Storage - All Operators Alaska Underground Natural Gas Storage - All Operators Injections of Natural Gas into Storage (Annual Supply &...

343

Rhode Island Natural Gas Underground Storage Injections All Operators...  

U.S. Energy Information Administration (EIA) Indexed Site

of Natural Gas into Underground Storage - All Operators Rhode Island Underground Natural Gas Storage - All Operators Injections of Natural Gas into Storage (Annual Supply &...

344

Completion report: Raft River Geothermal Injection Well Six (RRGI-6)  

DOE Green Energy (OSTI)

Raft River Geothermal Injection Well Six (RRGI-6) is an intermediate-depth injection well designed to accept injection water in the 600 to 1000 m (2000 to 3500 ft) depth range. It has one barefoot leg, and it was drilled so that additional legs can be added later; if there are problems with intermediate-depth injection, one or more additional legs could be directionally drilled from the current well bore. Included are the reports of daily drilling records of drill bits, casings, and loggings, and descriptions of cementing, coring, and containment.

Miller, L.G.; Prestwich, S.M.

1979-02-01T23:59:59.000Z

345

Evaluation of Sorbent Injection for Mercury Control  

Science Conference Proceedings (OSTI)

The power industry in the U.S. is faced with meeting new regulations to reduce the emissions of mercury compounds from coal-fired plants. These regulations are directed at the existing fleet of nearly 1,100 boilers. These plants are relatively old with an average age of over 40 years. Although most of these units are capable of operating for many additional years, there is a desire to minimize large capital expenditures because of the reduced (and unknown) remaining life of the plant to amortize the project. Injecting a sorbent such as powdered activated carbon into the flue gas represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. The overall objective of the test program described in this quarterly report is to evaluate the capabilities of activated carbon injection at five plants with configurations that together represent 78% of the existing coal-fired generation plants. This technology was successfully evaluated in NETL's Phase I tests at scales up to 150 MW, on plants burning subbituminous and bituminous coals and with ESPs and fabric filters. The tests also identified issues that still need to be addressed, such as evaluating performance on other configurations, optimizing sorbent usage (costs), and gathering longer-term operating data to address concerns about the impact of activated carbon on plant equipment and operations. The four sites identified for testing are Sunflower Electric's Holcomb Station, AmerenUE's Meramec Station, AEP's Conesville Station, and Detroit Edison's Monroe Power Plant. In addition to tests identified for the four main sites, parametric testing at Missouri Basin Power Project's Laramie River Station Unit 3 has been scheduled and made possible through additional costshare participation targeted by team members specifically for tests at Holcomb or a similar plant. This is the fifth quarterly report for this project. Long-term testing was completed at Meramec during this reporting period. Preliminary results from parametric, baseline and long-term testing at Meramec are included in this report. Planning information for the other three sites is also included. In general, quarterly reports will be used to provide project overviews, project status, and technology transfer information. Topical reports will be prepared to present detailed technical information.

Sharon Sjostrom

2005-02-02T23:59:59.000Z

346

Evaluation of Sorbent Injection for Mercury Control  

SciTech Connect

The power industry in the U.S. is faced with meeting new regulations to reduce the emissions of mercury compounds from coal-fired plants. These regulations are directed at the existing fleet of nearly 1,100 boilers. These plants are relatively old with an average age of over 40 years. Although most of these units are capable of operating for many additional years, there is a desire to minimize large capital expenditures because of the reduced (and unknown) remaining life of the plant to amortize the project. Injecting a sorbent such as powdered activated carbon into the flue gas represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. This is the final site report for tests conducted at DTE Energy's Monroe Power Plant, one of five sites evaluated in this DOE/NETL program. The overall objective of the test program was to evaluate the capabilities of activated carbon injection at five plants: Sunflower Electric's Holcomb Station Unit 1, AmerenUE's Meramec Station Unit 2, Missouri Basin Power Project's Laramie River Station Unit 3, Detroit Edison's Monroe Power Plant Unit 4, and AEP's Conesville Station Unit 6. These plants have configurations that together represent 78% of the existing coal-fired generation plants. The goals for the program established by DOE/NETL were to reduce the uncontrolled mercury emissions by 50 to 70% at a cost 25 to 50% lower than the target established by DOE of $60,000/lb mercury removed. The results from Monroe indicate that using DARCO{reg_sign} Hg would result in higher mercury removal (80%) at a sorbent cost of $18,000/lb mercury, or 70% lower than the benchmark. These results demonstrate that the goals established by DOE/NETL were exceeded during this test program. The increase in mercury removal over baseline conditions is defined for this program as a comparison in the outlet emissions measured using the Ontario Hydro method during the baseline and long-term test periods. The change in outlet emissions from baseline to long-term testing was 81%.

Sharon Sjostrom

2006-04-30T23:59:59.000Z

347

Experimental comparison of hot water/propane injection to steam/propane injection for recovery of heavy oil.  

E-Print Network (OSTI)

??Generating enough heat to convert water into steam is a major expense for projects that inject steam into reservoirs to enhance hydrocarbon recovery. If the… (more)

Nesse, Thomas

2005-01-01T23:59:59.000Z

348

Evaluation of Sorbent Injection for Mercury Control  

Science Conference Proceedings (OSTI)

ADA-ES, Inc., with support from DOE/NETL, EPRI, and industry partners, studied mercury control options at six coal-fired power plants. The overall objective of the this test program was to evaluate the capabilities of activated carbon injection at six plants: Sunflower Electric's Holcomb Station Unit 1, AmerenUE's Meramec Station Unit 2, Missouri Basin Power Project's Laramie River Station Unit 3, Detroit Edison's Monroe Power Plant Unit 4, American Electric Power's Conesville Station Unit 6, and Labadie Power Plant Unit 2. These plants have configurations that together represent 78% of the existing coal-fired generation plants. The financial goals for the program established by DOE/NETL were to reduce the uncontrolled mercury emissions by 50 to 70% at a cost 25 to 50% lower than the target established by DOE of $60,000 per pound of mercury removed. Results from testing at Holcomb, Laramie, Meramec, Labadie, and Monroe indicate the DOE goal was successfully achieved. However, further improvements for plants with conditions similar to Conesville are recommended that would improve both mercury removal performance and economics.

Sharon Sjostrom

2008-06-30T23:59:59.000Z

349

An Improved Beam Screen for the LHC Injection Kickers  

E-Print Network (OSTI)

The two LHC injection kicker magnet systems must produce a kick of 1.3 T.m with a flattop duration variable up to 7860 ns, and rise and fall times of less than 900 ns and 3000 ns, respectively. Each system is composed of two resonant charging power supplies (RCPSs) and four 5 WW transmission line kicker magnets with matched terminating resistors and pulse forming networks (PFNs). A beam screen is placed in the aperture of the magnets: the screen consists of a ceramic tube with conductors on the inner wall. The conductors provide a path for the image current of the, high intensity, LHC beam and screen the ferrite against Wake fields. The conductors initially used gave adequately low beam coupling impedance however inter-conductor discharges occurred during pulsing of the magnet: an alternative design was discharge free at the nominal operating voltage but the impedance was too high for the ultimate LHC beam. This paper presents the results of a new development undertaken to meet the often conflicting requireme...

Barnes, M J; Ducimetière, L; Garrel, N; Kroyer, T

2007-01-01T23:59:59.000Z

350

Adaptable Inverter for Injection of Fuel Cell and Photovoltaic Power  

E-Print Network (OSTI)

important to apply renewable energies and efficient technologies. For power injection of photovoltaic with different energy sources such as photovoltaic, fuel cell and battery. It is possible to adjust active inverter. These inverters for injection of photovoltaic energy are developed only for this purpose

Kulig, Stefan

351

An immiscible WAG injection project in the Kuparuk River Unit  

SciTech Connect

Immiscible water-alternating-gas (WAG) injection has been successfully used in the Kuparuk River Unit as a means of controlling excess gas production. Additionally, simulation results have indicated that WAG injection can increase economic oil recovery by improving waterflood conformance. WAG recovery mechanisms, simulation results, field performance, and field surveillance are discussed.

Champion, J.H.; Sheldon, J.B.

1989-05-01T23:59:59.000Z

352

Medium energy pitch angle distribution during substorm injected electron clouds  

E-Print Network (OSTI)

Medium energy pitch angle distribution during substorm injected electron clouds A. A° snes,1 J, N. �stgaard, and M. Thomsen (2005), Medium energy pitch angle distribution during substorm injected to obtain pitch angle resolved electron distribution data for measurements at energies 10 eV to 47 keV. [3

Bergen, Universitetet i

353

A simulation study of steam and steam-propane injection using a novel smart horizontal producer to enhance oil production  

E-Print Network (OSTI)

A 3D 8-component thermal compositional simulation study has been performed to evaluate the merits of steam-propane injection and a novel vertical-smart horizontal well system for the Lombardi reservoir in the San Ardo field, California. The novel well system consists of a vertical steam injector and a horizontal producer, whose horizontal section is fully open initially, and after steam breakthrough, only one-third (heel-end) is kept open. A 16x16x20 Cartesian model was used that represented a quarter of a typical 10acre 9-spot inverted steamflood pattern in the field. The prediction cases studied assume prior natural depletion to reservoir pressure of about 415 psia. Main results of the simulation study may be summarized as follows. First, under steam injection, oil recovery is significantly higher with the novel vertical-smart horizontal well system (45.5-58.7% OOIP at 150-300 BPDCWE) compared to the vertical well system (33.6-32.2% OOIP at 150-300 BPDCWE). Second, oil recovery increases with steam injection rate in the vertical-smart horizontal well system but appears to reach a maximum at about 150 BPDCWE in the vertical well system (due to severe bypassing of oil). Third, under steam-propane injection, oil recovery for the vertical-smart horizontal well system increases to 46.1% OOIP at 150 BPDCWE but decreases to 51.6% OOIP at 300 PDCWE due to earlier steam breakthrough that resulted in reduced sweep efficiency. Fourth, for the vertical well system, steam-propane injection results in an increase of oil recovery to 35.4-32.6% OOIP at 150-300 BPDCWE. Fifth, with steam-propane injection, for both well systems, oil production acceleration increases with lower injection rates. Sixth, the second oil production peak in the vertical-smart horizontal well system is accelerated by 24-50% in time for 150-300 BPDCWE compared to that with pure steam injection.

Sandoval Munoz, Jorge Eduardo

2004-08-01T23:59:59.000Z

354

U-174: Serendipity Unspecified SQL Injection Vulnerability | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4: Serendipity Unspecified SQL Injection Vulnerability 4: Serendipity Unspecified SQL Injection Vulnerability U-174: Serendipity Unspecified SQL Injection Vulnerability May 22, 2012 - 7:00am Addthis PROBLEM: Serendipity Unspecified SQL Injection Vulnerability PLATFORM: 1.6.1 and prior versions ABSTRACT: A vulnerability was reported in Serendipity. A remote user can inject SQL commands. Reference Links: SecurityTracker Alert ID: 1027079 Secunia Advisory SA49234 CVE-2012-2762 IMPACT ASSESSMENT: Medium Discussion: The 'include/functions_trackbacks.inc.php' script does not properly validate user-supplied input. A remote user can supply a specially crafted parameter value to execute SQL commands on the underlying database. Impact: A remote user can execute SQL commands on the underlying database. Solution: The vendor has issued a fix (1.6.2).

355

V-170: Apache Subversion Hook Scripts Arbitrary Command Injection  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

0: Apache Subversion Hook Scripts Arbitrary Command Injection 0: Apache Subversion Hook Scripts Arbitrary Command Injection Vulnerability V-170: Apache Subversion Hook Scripts Arbitrary Command Injection Vulnerability June 4, 2013 - 12:17am Addthis PROBLEM: Apache Subversion Hook Scripts Arbitrary Command Injection Vulnerability PLATFORM: Apache Subversion 1.x ABSTRACT: A vulnerability has been reported in Apache Subversion. REFERENCE LINKS: Apache Original Advisory Secunia Advisory SA53727 CVE-2013-2088 IMPACT ASSESSMENT: Medium DISCUSSION: The vulnerability is caused due to an input validation error in the svn-keyword-check.pl hook script while processing filenames and can be exploited to inject and execute arbitrary shell commands via a specially crafted request. Successful exploitation requires that contrib scripts are used on the

356

U-251: Bugzilla LDAP Injection and Information Disclosure Vulnerabilities |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1: Bugzilla LDAP Injection and Information Disclosure 1: Bugzilla LDAP Injection and Information Disclosure Vulnerabilities U-251: Bugzilla LDAP Injection and Information Disclosure Vulnerabilities September 5, 2012 - 6:00am Addthis PROBLEM: Bugzilla LDAP Injection and Information Disclosure Vulnerabilities PLATFORM: Bugzilla 2.x Bugzilla 3.x Bugzilla 4.x ABSTRACT: Bugzilla is prone to an LDAP-injection vulnerability and an information-disclosure vulnerability reference LINKS: Bugzilla Homepage Bugzilla Security Advisory Bugtraq ID: 55349 Secunia Advisory SA50433 CVE-2012-3981 CVE-2012-4747 IMPACT ASSESSMENT: Medium Discussion: A vulnerability and a security issue have been reported, which can be exploited by malicious people to disclose potentially sensitive information and manipulate certain data. 1) Input passed via the username is not properly escaped before being used

357

Fully Coupled Well Models for Fluid Injection and Production  

SciTech Connect

Wells are the primary engineered component of geologic sequestration systems with deep subsurface reservoirs. Wells provide a conduit for injecting greenhouse gases and producing reservoirs fluids, such as brines, natural gas, and crude oil, depending on the target reservoir. Well trajectories, well pressures, and fluid flow rates are parameters over which well engineers and operators have control during the geologic sequestration process. Current drilling practices provided well engineers flexibility in designing well trajectories and controlling screened intervals. Injection pressures and fluids can be used to purposely fracture the reservoir formation or to purposely prevent fracturing. Numerical simulation of geologic sequestration processes involves the solution of multifluid transport equations within heterogeneous geologic media. These equations that mathematically describe the flow of fluid through the reservoir formation are nonlinear in form, requiring linearization techniques to resolve. In actual geologic settings fluid exchange between a well and reservoir is a function of local pressure gradients, fluid saturations, and formation characteristics. In numerical simulators fluid exchange between a well and reservoir can be specified using a spectrum of approaches that vary from totally ignoring the reservoir conditions to fully considering reservoir conditions and well processes. Well models are a numerical simulation approach that account for local conditions and gradients in the exchange of fluids between the well and reservoir. As with the mathematical equations that describe fluid flow in the reservoir, variation in fluid properties with temperature and pressure yield nonlinearities in the mathematical equations that describe fluid flow within the well. To numerically simulate the fluid exchange between a well and reservoir the two systems of nonlinear multifluid flow equations must be resolved. The spectrum of numerical approaches for resolving these equations varies from zero coupling to full coupling. In this paper we describe a fully coupled solution approach for well model that allows for a flexible well trajectory and screened interval within a structured hexahedral computational grid. In this scheme the nonlinear well equations have been fully integrated into the Jacobian matrix for the reservoir conservation equations, minimizing the matrix bandwidth.

White, Mark D.; Bacon, Diana H.; White, Signe K.; Zhang, Z. F.

2013-08-05T23:59:59.000Z

358

Impact of Chemical Injections on Boiling Water Reactor Dose Rates: Interim Report  

Science Conference Proceedings (OSTI)

This report investigates the effects of Boiling Water Reactor (BWR) chemistry parameters on radiation field generation, with a focus on the higher reactor water Co-60 activity levels observed at plants using On-line NobleChem™ (OLNC) injections. Correlation and response curves were developed to relate reactor water and feedwater chemistry to dose rates, with the goal of improving reactor recirculation system (RRS) piping shutdown dose rate ...

2012-12-21T23:59:59.000Z

359

Electron bunch injection at an angle into a laser wakefield  

E-Print Network (OSTI)

External injection of electron bunches longer than the plasma wavelength in a laser wakefield accelerator can lead to the generation of femtosecond ultrarelativistic bunches with a couple of percent energy spread. Extensive study has been done on external electron bunch (e.g. one generated by a photo-cathode rf linac) injection in a laser wakefield for different configurations. In this paper we investigate a new way of external injection where the electron bunch is injected at a small angle into the wakefield. This way one can avoid the ponderomotive scattering as well as the vacuum-plasma transition region, which tend to destroy the injected bunch. In our simulations, the effect of the laser pulse dynamics is also taken into account. It is shown that injection at an angle can provide compressed and accelerated electron bunches with less than 2% energy spread. Another advantage of this scheme is that it has less stringent requirements in terms of the size of the injected bunch and there is the potential to tr...

Luttikhof, M J H; Van Goor, F A; Boller, K -J

2008-01-01T23:59:59.000Z

360

Duct injection for SO{sub 2} control, Design Handbook, Volume 1, Process design and engineering guidelines  

SciTech Connect

PETC developed a comprehensive program of coal-related, acid-rain research and development with a major activity area centering on flue gas cleanup and control of SO{sub 2} emissions. Particular emphasis was placed on the retrofit measures for older coal-fired power plants which predate the 1971 New Source Performance Standards. Candidate emission control technologies fall into three categories, depending upon their point of application along the fuel path (i.e., pre, during, or post combustion). The post-combustion, in-duct injection of a calcium-based chemical reagent seemed promising. Preliminary studies showed that reagent injection between the existing air heater and electrostatic precipitator (ESP) could remove between 50-60% of the SO{sub 2} and produce an environmentally safe, dry, solid waste that is easily disposed. Although SO{sub 2} removal efficiencies were less, the estimated capital costs for duct injection technology were low making the economics of duct injection systems seem favorable when compared to conventional wet slurry scrubbers under certain circumstances. With the promulgation of the Clean Air Act Amendments of 1990 came more incentive for the development of low capital cost flue gas desulfurization (FGD) processes. A number of technical problems had to be resolved, however, before duct injection technology could be brought to a state of commercial readiness. The Duct Injection Technology Development Program was launched as a comprehensive, four-year research effort undertaken by PETC to develop this new technology. Completed in 1992, this Duct Injection Design Handbook and the three-dimensional predictive mathematical model constitute two primary end products from this development program. The aim of this design handbook and the accompanying math model is to provide utility personnel with sufficient information to evaluate duct injection technology against competing SO{sub 2} emissions reduction strategies for an existing plant.

NONE

1995-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "injection dsi systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Injection, compression and stability of intense ion-rings  

SciTech Connect

Recent advances in pulsed high power ion beam technology make possible the creation of intense ion-rings with strong self-magnetic fields by single pulse injection. Such ion rings have several uses in controlled fusion e.g., to produce a min parallel B parallel magnetic geometry with a mirror ratio much higher than is possible with external conductors. For even stronger ion rings a min parallel B parallel with closed lines of force (ASTRON type) can be created. For this purpose, since the ion energies required are much higher than are available from high power sources, magnetic compression can be utilized to increase the ion energy. The success of this scheme depends critically on the stability of the ion ring. The low frequency perturbations of the ring-plasma system is examined by means of a generalization of the energy principle which established sufficient conditions for stability. The high-frequency micro- instabilities and their nonlinear consequences are discussed in terms of conventional techniques. (auth)

Sudan, R.N.

1975-01-01T23:59:59.000Z

362

Spin Injection Across a Heterojunction: A Ballistic Picture  

SciTech Connect

Spin injection across heterojunctions plays a decisive role in the new field of spintronics. Within the ballistic transport regime, we state a general expression for the spin-injection rate in a heterojunction made of two ballistic electrodes. Both the spin-orbit interaction and interface scattering effect are taken into account. Our model is consistent with the well-documented results of ferromagnetic-metal junctions. It explains the recent experimental results of a dilute-magnetic-semiconductor/semiconductor junction and predicts solutions to enhance the spin-injection rate across a ferromagnetic-semiconductor junction.

Hu, C.-M.; Matsuyama, T.

2001-08-06T23:59:59.000Z

363

Fluid injection profiles: modern analysis of wellbore temperature survey  

DOE Green Energy (OSTI)

Exact and approximate solutions for heat flow in a fluid injection well are presented. By using the approximate results, temperature surveys can be quickly analyzed in the field, and the well depths where fluids leave and the departing flow rates at these depths can be precisely determined. Although this method eliminates the need for indigenous and post injection shut-in temperatures, several surveys must be taken just before and during the injection period which can be as short as several hours. In the application described the method was used to locate the depths where hydraulic fractures were initiated in a hot dry rock geothermal well.

Murphy, H.D.

1977-01-01T23:59:59.000Z

364

Compendium of Regulatory Requirements Governing Underground Injection of Drilling Wastes  

Science Conference Proceedings (OSTI)

This report provides a comprehensive compendium of the regulatory requirements governing the injection processes used for disposing of drilling wastes; in particular, for a process referred to in this report as slurry injection. The report consists of a narrative discussion of the regulatory requirements and practices for each of the oil- and gas-producing states, a table summarizing the types of injection processes authorized in each state, and an appendix that contains the text of many of the relevant state regulations and policies.

Puder, Markus G.; Bryson, Bill; Veil, John A.

2003-03-03T23:59:59.000Z

365

Steam-injected gas turbines uneconomical with coal gasification equipment  

SciTech Connect

Researchers at the Electric Power Research Institute conducted a series of engineering and economic studies to assess the possibility of substituting steam-injected gas (STIG) turbines for the gas turbines currently proposed for use in British Gas Corporation (BGC)/Lurgi coal gasification-combined cycle plants. The study sought to determine whether steam-injected gas turbines and intercooled steam-injected gas turbines, as proposed by General Electric would be economically competitive with conventional gas and steam turbines when integrated with coal gasification equipment. The results are tabulated in the paper.

1986-09-01T23:59:59.000Z

366

Pressurized feed-injection spray-forming apparatus  

SciTech Connect

A spray apparatus and method for injecting a heated, pressurized liquid in a first predetermined direction into a pressurized gas flow that is flowing in a second predetermined direction, to provide for atomizing and admixing the liquid with the gas to form a two-phase mixture. A valve is also disposed within the injected liquid conduit to provide for a pulsed injection of the liquid and timed deposit of the atomized gas phase. Preferred embodiments include multiple liquid feed ports and reservoirs to provide for multiphase mixtures of metals, ceramics, and polymers.

Berry, Ray A. (Idaho Falls, ID); Fincke, James R. (Idaho Falls, ID); McHugh, Kevin M. (Idaho Falls, ID)

1995-01-01T23:59:59.000Z

367

Alkaline injection for enhanced oil recovery: a status report  

SciTech Connect

In the past several years, there has been renewed interest in enhanced oil recovery (EOR) by alkaline injection. Alkaline solutions also are being used as preflushes in micellar/polymer projects. Several major field tests of alkaline flooding are planned, are in progress, or recently have been completed. Considerable basic research on alkaline injection has been published recently, and more is in progress. This paper summarizes known field tests and, where available, the amount of alkali injected and the performance results. Recent laboratory work, much sponsored by the U.S. DOE, and the findings are described. Alkaline flood field test plans for new projects are summarized.

Mayer, E.H.; Berg, R.L.; Carmichael, J.D.; Weinbrandt, R.M.

1983-01-01T23:59:59.000Z

368

CarbFix CO2 Injection Pilot Project, J. M. Matter, M. Stute & W. Broecker  

E-Print Network (OSTI)

Fix Injection Site #12;A Conceptual Carbonation Model Injec8on well: CO2 fully dissolvedCarbFix CO2 Injection Pilot Project, Iceland J. M. Matter, M. Stute & W. Broecker Lamont Pétursson #12;CarbFix Injection Site #12;CarbFix CO2 Injection Site #12;CarbFix Injection Site 2

369

Injection, flow, and mixing of CO2 in porous media with residual gas.  

Science Conference Proceedings (OSTI)

Geologic structures associated with depleted natural gas reservoirs are desirable targets for geologic carbon sequestration (GCS) as evidenced by numerous pilot and industrial-scale GCS projects in these environments world-wide. One feature of these GCS targets that may affect injection is the presence of residual CH{sub 4}. It is well known that CH{sub 4} drastically alters supercritical CO{sub 2} density and viscosity. Furthermore, residual gas of any kind affects the relative permeability of the liquid and gas phases, with relative permeability of the gas phase strongly dependent on the time-history of imbibition or drainage, i.e., dependent on hysteretic relative permeability. In this study, the effects of residual CH{sub 4} on supercritical CO{sub 2} injection were investigated by numerical simulation in an idealized one-dimensional system under three scenarios: (1) with no residual gas; (2) with residual supercritical CO{sub 2}; and (3) with residual CH{sub 4}. We further compare results of simulations that use non-hysteretic and hysteretic relative permeability functions. The primary effect of residual gas is to decrease injectivity by decreasing liquid-phase relative permeability. Secondary effects arise from injected gas effectively incorporating residual gas and thereby extending the mobile gas plume relative to cases with no residual gas. Third-order effects arise from gas mixing and associated compositional effects on density that effectively create a larger plume per unit mass. Non-hysteretic models of relative permeability can be used to approximate some parts of the behavior of the system, but fully hysteretic formulations are needed to accurately model the entire system.

Oldenburg, C.M.; Doughty, C.A.

2010-09-01T23:59:59.000Z

370

CO2 Injection in Kansas Oilfield Could Greatly Increase Production,  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

CO2 Injection in Kansas Oilfield Could Greatly Increase Production, CO2 Injection in Kansas Oilfield Could Greatly Increase Production, Permanently Store Carbon Dioxide, DOE Study Says CO2 Injection in Kansas Oilfield Could Greatly Increase Production, Permanently Store Carbon Dioxide, DOE Study Says August 31, 2011 - 1:00pm Addthis Washington, DC - The feasibility of using carbon dioxide (CO2) injection for recovering between 250 million and 500 million additional barrels of oil from Kansas oilfields has been established in a study funded by the U.S. Department of Energy (DOE). The University of Kansas Center for Research studied the possibility of near-miscible CO2 flooding for extending the life of mature oilfields in the Arbuckle Formation while simultaneously providing permanent geologic storage of carbon dioxide, a major greenhouse gas.

371

one mile underground into a deep saline formation. The injection  

NLE Websites -- All DOE Office Websites (Extended Search)

mile underground into a deep saline formation. The injection, mile underground into a deep saline formation. The injection, which will occur over a three-year period and is slated to start in early 2010, will compress up to 1 million metric tonnes of CO 2 from the ADM ethanol facility into a liquid-like, dense phase. The targeted rock formation, the Mt. Simon Sandstone, is the thickest and most widespread saline reservoir in the Illinois Basin, with an estimated CO 2 storage capacity of 27 to 109 billion metric tonnes. A comprehensive monitoring program, which will be evaluated yearly, will be implemented after the injection to ensure the injected CO 2 is stored safely and permanently. The RCSP Program was launched by the Office of Fossil Energy (FE)

372

Development of an injection augmentation program at the Dixie Valley,  

Open Energy Info (EERE)

an injection augmentation program at the Dixie Valley, an injection augmentation program at the Dixie Valley, Nevada geothermal field Jump to: navigation, search OpenEI Reference LibraryAdd to library Conference Paper: Development of an injection augmentation program at the Dixie Valley, Nevada geothermal field Abstract Evaporative cooling at geothermal power plants generally reduces reservoir pressures even if all available geothermal liquids are reinjected. Controlled programs of injecting non geothermal waters directly into reservoirs have been tested or implemented at only four fields, three of them being vapor dominated. At the liquid-dominated Dixie Valley geothermal field an unsuccessful search for a large volume source of warm,chemically desirable fluid for augmentation was conducted.After determining water

373

Premixed direct injection nozzle for highly reactive fuels  

Science Conference Proceedings (OSTI)

A fuel/air mixing tube for use in a fuel/air mixing tube bundle is provided. The fuel/air mixing tube includes an outer tube wall extending axially along a tube axis between an inlet end and an exit end, the outer tube wall having a thickness extending between an inner tube surface having a inner diameter and an outer tube surface having an outer tube diameter. The tube further includes at least one fuel injection hole having a fuel injection hole diameter extending through the outer tube wall, the fuel injection hole having an injection angle relative to the tube axis. The invention provides good fuel air mixing with low combustion generated NOx and low flow pressure loss translating to a high gas turbine efficiency, that is durable, and resistant to flame holding and flash back.

Ziminsky, Willy Steve; Johnson, Thomas Edward; Lacy, Benjamin Paul; York, William David; Uhm, Jong Ho; Zuo, Baifang

2013-09-24T23:59:59.000Z

374

Underground Injection Control Program Rules and Regulations (Rhode Island)  

Energy.gov (U.S. Department of Energy (DOE))

The purpose of this regulation is to preserve the quality of the groundwater of the State and thereby protect groundwater contamination from contamination by discharge from injection wells and...

375

The reduction of supersonic jet noise using pulsed microjet injection  

E-Print Network (OSTI)

This thesis is concerned with the active control of supersonic jet noise using pulsed microjet injection at the nozzle exit. Experimental investigations were carried out using this control method on an ideally expanded ...

Ragaller, Paul Aaron

2007-01-01T23:59:59.000Z

376

The design, manufacturing and use of economically friendly injection molds  

E-Print Network (OSTI)

Much of the polymer manufacturing done today involves the process of injection molding. It can be difficult to gain experience in the art of designing and building tooling for this process outside of industry. The goal of ...

Buchok, Aaron (Aaron J.)

2008-01-01T23:59:59.000Z

377

Non-uniform emission studies of a magnetron injection gun  

E-Print Network (OSTI)

This thesis investigates the experimental measurement and theoretical simulation of the effects of azimuthal emission non-uniformity of a 96 kV, 40 amp magnetron injection gun (MIG) used in a gyrotron. The accomplishments ...

Marchewka, Chad D. (Chad Daniel)

2006-01-01T23:59:59.000Z

378

Cost Estimate of Activated Carbon Injection for Controlling Mercury...  

NLE Websites -- All DOE Office Websites (Extended Search)

mercury reductions of between 60% and 70% at injection rates around 10-15 lbsmillion acf (see Figure 1). Although regression analysis of full-scale ACIESP data shows that it...

379

Lithium pellet injection into high pressure magnetically confined plasmas  

E-Print Network (OSTI)

The ablation of solid pellets injected into high temperature magnetically confined plasmas is characterized by rapid oscillations in the ablation rate, and the formation of field aligned filaments in the ablatant. High ...

Böse, Brock (Brock Darrel)

2010-01-01T23:59:59.000Z

380

Improved screen-bowl centrifuge recovery using polymer injection technology  

Science Conference Proceedings (OSTI)

The paper reports the improved screen-bowl centrifuge recovery process using polymer injection technology. Field test and economic analysis are also included in the paper. 3 refs., 3 figs., 1 tab.

Burchett, R.T.; McGough, K.M.; Luttrell, G.H.

2006-08-15T23:59:59.000Z

Note: This page contains sample records for the topic "injection dsi systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Victor J. Daniel Jr. CO2 Injection Test Site Plan  

NLE Websites -- All DOE Office Websites (Extended Search)

Mississippi Test Site JAF02664.PPT 1 1.1 SITE BACKGROUND 1.2 GENERAL IDENTIFICATION DATA 1.3 REGULATORY CLASSIFICATION 1.4 WELL DATA - INJECTION WELL NO. 1 1.5 WELL DATA -...

382

Collagen scaffolds and injectable biopolymer gels for cardiac tissue engineering  

E-Print Network (OSTI)

Three-dimensional biomaterial scaffolds have begun to shown promise for cell delivery for cardiac tissue engineering. Although various polymers and material forms have been explored, there is a need for: injectable gels ...

Ng, Karen Kailin

2012-01-01T23:59:59.000Z

383

NETL: News Release - Illinois CO2 Injection Project Moves Another...  

NLE Websites -- All DOE Office Websites (Extended Search)

5, 2010 Illinois CO2 Injection Project Moves Another Step Forward Baseline Data Important for CCS Project's Planned 2011 Startup Washington, D.C. - The recent completion of a...

384

Fractured reservoir characterization through injection, falloff, and flowback tests  

SciTech Connect

This paper presents the development of a multiphase pressure-transient-analysis technique for naturally fractured reservoirs and the analysis of a series of field tests performed to evaluate the water injection potential and the reservoir characteristics of a naturally fractured reservoir. These included step-rate, water-injectivity, pressure-falloff, and flowback tests. Through these tests, a description of the reservoir was obtained.

Peng, C.P.; Singh, P.K. (Amoco Production Co., Tulsa, OK (United States)); Halvorsen, H. (Amoco Norway Oil Co., Stavanger (NO)); York, S.D. (Amoco Production Co., Houston, TX (United States))

1992-09-01T23:59:59.000Z

385

Apparatus and method for downhole injection of radioactive tracer  

SciTech Connect

The disclosure relates to downhole injection of radioactive .sup.82 Br and monitoring its progress through fractured structure to determine the nature thereof. An ampule containing granular .sup.82 Br is remotely crushed and water is repeatedly flushed through it to cleanse the instrument as well as inject the .sup.82 Br into surrounding fractured strata. A sensor in a remote borehole reads progress of the radioactive material through fractured structure.

Potter, Robert M. (Los Alamos, NM); Archuleta, Jacobo R. (Espanola, NM); Fink, Conrad F. (Los Alamos, NM)

1983-01-01T23:59:59.000Z

386

Optoelectronic device with nanoparticle embedded hole injection/transport layer  

DOE Patents (OSTI)

An optoelectronic device is disclosed that can function as an emitter of optical radiation, such as a light-emitting diode (LED), or as a photovoltaic (PV) device that can be used to convert optical radiation into electrical current, such as a photovoltaic solar cell. The optoelectronic device comprises an anode, a hole injection/transport layer, an active layer, and a cathode, where the hole injection/transport layer includes transparent conductive nanoparticles in a hole transport material.

Wang, Qingwu (Chelmsford, MA); Li, Wenguang (Andover, MA); Jiang, Hua (Methuen, MA)

2012-01-03T23:59:59.000Z

387

Sorbent Injection for Small ESP Mercury Control in Low Sulfur Eastern Bituminous Coal Flue Gas  

SciTech Connect

This project Final Report is submitted to the U.S. Department of Energy (DOE) as part of Cooperative Agreement DE-FC26-03NT41987, 'Sorbent Injection for Small ESP Mercury Control in Low Sulfur Eastern Bituminous Coal Flue Gas.' Sorbent injection technology is targeted as the primary mercury control process on plants burning low/medium sulfur bituminous coals equipped with ESP and ESP/FGD systems. About 70% of the ESPs used in the utility industry have SCAs less than 300 ft2/1000 acfm. Prior to this test program, previous sorbent injection tests had focused on large-SCA ESPs. This DOE-NETL program was designed to generate data to evaluate the performance and economic feasibility of sorbent injection for mercury control at power plants that fire bituminous coal and are configured with small-sized electrostatic precipitators and/or an ESP-flue gas desulfurization (FGD) configuration. EPRI and Southern Company were co-funders for the test program. Southern Company and Reliant Energy provided host sites for testing and technical input to the project. URS Group was the prime contractor to NETL. ADA-ES and Apogee Scientific Inc. were sub-contractors to URS and was responsible for all aspects of the sorbent injection systems design, installation and operation at the different host sites. Full-scale sorbent injection for mercury control was evaluated at three sites: Georgia Power's Plant Yates Units 1 and 2 [Georgia Power is a subsidiary of the Southern Company] and Reliant Energy's Shawville Unit 3. Georgia Power's Plant Yates Unit 1 has an existing small-SCA cold-side ESP followed by a Chiyoda CT-121 wet scrubber. Yates Unit 2 is also equipped with a small-SCA ESP and a dual flue gas conditioning system. Unit 2 has no SO2 control system. Shawville Unit 3 is equipped with two small-SCA cold-side ESPs operated in series. All ESP systems tested in this program had SCAs less than 250 ft2/1000 acfm. Short-term parametric tests were conducted on Yates Units 1 and 2 to evaluate the performance of low-cost activated carbon sorbents for removing mercury. In addition, the effects of the dual flue gas conditioning system on mercury removal performance were evaluated as part of short-term parametric tests on Unit 2. Based on the parametric test results, a single sorbent (e.g., RWE Super HOK) was selected for a 30-day continuous injection test on Unit 1 to observe long-term performance of the sorbent as well as its effects on ESP and FGD system operations as well as combustion byproduct properties. A series of parametric tests were also performed on Shawville Unit 3 over a three-week period in which several activated carbon sorbents were injected into the flue gas duct just upstream of either of the two Unit 3 ESP units. Three different sorbents were evaluated in the parametric test program for the combined ESP 1/ESP 2 system in which sorbents were injected upstream of ESP 1: RWE Super HOK, Norit's DARCO Hg, and a 62:38 wt% hydrated lime/DARCO Hg premixed reagent. Five different sorbents were evaluated for the ESP 2 system in which activated carbons were injected upstream of ESP 2: RWE Super HOK and coarse-ground HOK, Norit's DARCO Hg and DARCO Hg-LH, and DARCO Hg with lime injection upstream of ESP 1. The hydrated lime tests were conducted to reduce SO3 levels in an attempt to enhance the mercury removal performance of the activated carbon sorbents. The Plant Yates and Shawville studies provided data required for assessing carbon performance and long-term operational impacts for flue gas mercury control across small-sized ESPs, as well as for estimating the costs of full-scale sorbent injection processes.

Carl Richardson; Katherine Dombrowski; Douglas Orr

2006-12-31T23:59:59.000Z

388

Booster gold beam injection efficiency and beam loss  

SciTech Connect

The Relativistic Heavy Ion Collider (RHIC) at the BNL requires the AGS to provide gold beam with the intensity of 10{sup 9} ions per bunch. Over the years, the Tandem Van de Graaff has provided steadily increasing intensity of gold ion beams to the AGS Booster. However, the gold ion beam injection efficiency at the Booster has been found to decrease with the rising intensity of injected beams. As the result, for Tandem beams of the highest intensity, the Booster late intensity is lower than with slightly lower intensity Tandem beam. In this article, the authors present two experiments associated with the Booster injection efficiency and beam intensity. One experiment looks at the Booster injection efficiency by adjusting the Tandem beam intensity, and another looks at the beam life time while scraping the beam in the Booster. The studies suggest that the gold beam injection efficiency at the AGS Booster is related to the beam loss in the ring, rather than the intensity of injected beam or circulating beam.

Zhang, S.Y.; Ahrens, L.A.

1998-08-01T23:59:59.000Z

389

Geothermal injection treatment: process chemistry, field experiences, and design options  

DOE Green Energy (OSTI)

The successful development of geothermal reservoirs to generate electric power will require the injection disposal of approximately 700,000 gal/h (2.6 x 10/sup 6/ 1/h) of heat-depleted brine for every 50,000 kW of generating capacity. To maintain injectability, the spent brine must be compatible with the receiving formation. The factors that influence this brine/formation compatibility and tests to quantify them are discussed in this report. Some form of treatment will be necessary prior to injection for most situations; the process chemistry involved to avoid and/or accelerate the formation of precipitate particles is also discussed. The treatment processes, either avoidance or controlled precipitation approaches, are described in terms of their principles and demonstrated applications in the geothermal field and, when such experience is limited, in other industrial use. Monitoring techniques for tracking particulate growth, the effect of process parameters on corrosion and well injectability are presented. Examples of brine injection, preinjection treatment, and recovery from injectivity loss are examined and related to the aspects listed above.

Kindle, C.H.; Mercer, B.W.; Elmore, R.P.; Blair, S.C.; Myers, D.A.

1984-09-01T23:59:59.000Z

390

Hydrothermal Injection Research Program. Annual progress report, FY 1983  

DOE Green Energy (OSTI)

The test program was initiated at the Raft River Geothermal Field in southern Idaho in September of 1982. A series of eight short-term injection and backflow tests followed by a long-term injection test were conducted on one well in the field. Tracers were added during injection and monitored during backflow of the well. The test program was successful, resulting in a unique data set which shows promise as a means to improve understanding of the reservoir characteristics. In December of 1982 an RFP was issued to obtain an industrial partner to obtain follow-on data on the injection/backflow technique in a second field and to study any alternate advanced concepts for injection testing which the industrial community might recommend. Republic Geothermal, Inc. and the East Mesa Geothermal Field were selected for the second test series. Two wells were utilized for testing, and a series of ten tests were conducted in July and August of 1983 aimed principally at further evaluation of the injection/backflow technique. This test program was also successfully completed. This report describes in detail the analysis conducted on the Raft River data, the supporting work at EG and G Idaho and at ESL/UURI, and gives an overview of the objectives and test program at East Mesa.

Blackett, R.E.; Kolesar, P.T.; Capuano, R.G.; Sill, W.R.; Allman, D.W.; Hull, L.C.; Large, R.M.; Miller, J.D.; Skiba, P.A.; Downs, W.F.; Koslow, K.N.; McAtee, R.E.; Russell, B.F.

1983-11-01T23:59:59.000Z

391

Analysis of injection tests in liquid-dominated geothermal reservoirs  

DOE Green Energy (OSTI)

The objective was to develop procedures for analyzing nonisothermal injection test data during the early phases of injection. In particular, methods for determining the permeability-thickness of the formation, skin factor of the well and tracking the movement of the thermal front have been developed. The techniques developed for interpreting injection pressure transients are closely akin to conventional groundwater and petroleum techniques for evaluating these parameters. The approach taken was to numerically simulate injection with a variety of temperatures, reservoir parameters and flowrates, in order to determine the characteristic responses due to nonisothermal injection. Two characteristic responses were identified: moving front dominated behavior and composite reservoir behavior. Analysis procedures for calculating the permeability-thickness of the formation and the skin factor of the well have been developed for each of these cases. In order to interpret the composite reservior behavior, a new concept has been developed; that of a ''fluid skin factor'', which accounts for the steady-state pressure buildup due to the region inside the thermal front. Based on this same concept, a procedure for tracking the movement of the thermal front has been established. The results also identify the dangers of not accounting the nonisothermal effects when analyzing injection test data. Both the permeability-thickness and skin factor of the well can be grossly miscalculated if the effects of the cold-region around the well are not taken into consideration. 47 refs., 30 figs., 14 tabs.

Benson, S.M.

1984-12-01T23:59:59.000Z

392

Pressure buildup during supercritical carbon dioxide injection from a partially penetrating borehole into gas reservoirs  

E-Print Network (OSTI)

the vicinity of the injection well. While a large injectionby pumping it down into an injection well. While the actuala small part of the injection well (typically, a few meters

Mukhopadhyay, S.

2013-01-01T23:59:59.000Z

393

Coupled reservoir-geomechanical analysis of CO2 injection and ground deformations at In Salah, Algeria  

E-Print Network (OSTI)

is centered on one CO 2 injection well and consists of about1.5 km) horizontal injection wells. In an ongoing researchabove active CO 2 injection wells and the uplift pattern

Rutqvist, J.

2010-01-01T23:59:59.000Z

394

Continuous active-source seismic monitoring of CO2 injection in a brine aquifer  

E-Print Network (OSTI)

source deployed in the injection well. We first present thehas two wells, an injection well and a dedicated monitoringa sonic log of the injection well. We assumed the volume

Daley, Thomas M.; Solbau, Ray D.; Ajo-Franklin, Jonathan B.; Benson, Sally M.

2008-01-01T23:59:59.000Z

395

FY2001 Progress Report for the Spark Ignition Direct Injection R&D Program  

NLE Websites -- All DOE Office Websites (Extended Search)

SPARK IGNITION, SPARK IGNITION, DIRECT INJECTION ENGINE R&D 2 0 0 1 A N N U A L P R O G R E S S R E P O R T U.S. Department of Energy Energy Efficiency and Renewable Energy Office of Transportation Technologies A C K N O W L E D G E M E N T We would like to express our sincere appreciation to Argonne National Laboratory and Computer Systems Management, Inc., for their artistic and technical contributions in preparing and publishing this report. In addition, we would like to thank all our program participants for their contributions to the programs and all the authors who prepared the project abstracts that comprise this report. U.S. Department of Energy Office of Transportation Technologies 1000 Independence Avenue, S.W. Washington, DC 20585-0121 FY 2001 Progress Report for the Spark Ignition Direct Injection R&D Program

396

Collection efficiency of photoelectrons injected into near- and supercritical argon gas  

SciTech Connect

Injection of photoelectrons into gaseous or liquid dielectrics is a widely used technique to produce cold plasmas in weakly ionized systems for investigating the transport properties of electrons. We report measurements of the collection efficiency of photoelectrons injected into dense argon gas for T= 152.7 K, close to the critical temperature T{sub c} Almost-Equal-To 150.9 K, and for T= 200.0 K. The high-field data agree with the Young-Bradbury model and with previous measurements below T{sub c} and at an intermediate temperature above T{sub c}. The effective, density-dependent electron-atom momentum transfer scattering cross section can be deduced. However, the weak-field data near T{sub c} show large deviations from the theoretical model. We show that the electron behavior at weak field is influenced by electrostriction effects that are only important near the critical point.

Borghesani, A. F. [CNISM-Unit, Department of Physics and Astronomy, University of Padua, via F. Marzolo 8, I-35131 Padua (Italy); Lamp, P. [Max-Planck-Institut fuer Physik u. Astrophysik, Munich (Germany)

2013-01-21T23:59:59.000Z

397

Evaluation of bisphenol E cyanate ester for the resin-injection repair of advanced composites  

SciTech Connect

This thesis is a compilation of a general introduction and literature review that ties together the subsequent chapters which consist of two journal articles that have yet to be submitted for publication. The overall topic relates to the evaluation and application of a new class of cyanate ester resin with unique properties that lend it applicable to use as a resin for injection repair of high glass transition temperature polymer matrix composites. The first article (Chapter 2) details the evaluation and optimization of adhesive properties of this cyanate ester and alumina nanocomposites under different conditions. The second article (Chapter 3) describes the development and evaluation of an injection repair system for repairing delaminations in polymer matrix composites.

Wilber Yaote Lio

2009-12-19T23:59:59.000Z

398

A three-dimensional laboratory steam injection model allowing in situ saturation measurements. [Comparing steam injection and steam foam injection with nitrogen and without nitrogen  

SciTech Connect

The CT imaging technique together with temperature and pressure measurements were used to follow the steam propagation during steam and steam foam injection experiments in a three dimensional laboratory steam injection model. The advantages and disadvantages of different geometries were examined to find out which could best represent radial and gravity override flows and also fit the dimensions of the scanning field of the CT scanner. During experiments, steam was injected continuously at a constant rate into the water saturated model and CT scans were taken at six different cross sections of the model. Pressure and temperature data were collected with time at three different levels in the model. During steam injection experiments, the saturations obtained by CT matched well with the temperature data. That is, the steam override as observed by temperature data was also clearly seen on the CT pictures. During the runs where foam was present, the saturation distributions obtained from CT pictures showed a piston like displacement. However, the temperature distributions were different depending on the type of steam foam process used. The results clearly show that the pressure/temperature data alone are not sufficient to study steam foam in the presence of non-condensible gas.

Demiral, B.M.R.; Pettit, P.A.; Castanier, L.M.; Brigham, W.E.

1992-08-01T23:59:59.000Z

399

Systems  

E-Print Network (OSTI)

Abstract Developing usable and robust mixed reality systems requires unique human–computer interaction techniques and customized hardware systems. The design of the hardware is directed by the requirements of the rich 3D interactions that can be performed using immersive mobile MR systems. Geometry modeling and capture, navigational annotations, visualizations, and training simulations are all enhanced using augmented computer graphics. We present the design guidelines that have led us through 10 years of evolving mobile outdoor MR hardware systems.

Benjamin Avery; Ross T. Smith; Wayne Piekarski; Bruce H. Thomas

2009-01-01T23:59:59.000Z

400

Matched boundary extrapolation solutions for CO2 well injection into a saline aquifer  

E-Print Network (OSTI)

interface solution for carbon dioxide injection  into Interface  Solutionfor  Carbon  Dioxide  Injection  into IPCC  Special  Report  on  Carbon  Dioxide  Capture  and 

Houseworth, J.

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "injection dsi systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Collection and analyses of physical data for deep injection wells in Florida.  

E-Print Network (OSTI)

??Deep injection wells (DIW) in Florida are regulated by the U.S. Environmental Protection Agency (USEPA) and the state of Florida through the Underground Injection Control… (more)

Gao, Jie.

2010-01-01T23:59:59.000Z

402

Laser triggered injection of electrons in a laser wakefield accelerator with the colliding pulse method  

E-Print Network (OSTI)

Laser Triggered Injection ofElectrons in a Laser Wake?eld Accelerator with the CollidingAn injection scheme for a laser wake?eld accelerator that

2004-01-01T23:59:59.000Z

403

U-157: Ruby Mail Gem Directory Traversal and Shell Command Injection...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

57: Ruby Mail Gem Directory Traversal and Shell Command Injection Vulnerabilities U-157: Ruby Mail Gem Directory Traversal and Shell Command Injection Vulnerabilities April 27,...

404

Elastic and elastoplastic finite element simulations of injection into porous reservoirs.  

E-Print Network (OSTI)

??Underground gas injection has attracted remarkable attention for natural gas storage and carbon dioxide (CO2) geologic sequestration applications. Injection of natural gas into depleted hydrocarbon… (more)

Chamani, Amin

2013-01-01T23:59:59.000Z

405

BOOSTER GOLD BEAM INJECTION EFFICIENCY AND BEAM LOSS  

SciTech Connect

The Relativistic Heavy Ion Collider (RHIC) at the BNL requires the AGS to provide Gold beam with the intensity of 10{sup 9} ions per bunch. Over the years, the Tandem Van de Graaff has provided steadily increasing intensity of gold ion beams to the AGS Booster. However, the gold beam injection efficiency at the Booster has been found to decrease with the rising intensity of injected beams. As the result, for Tandem beams of the highest intensity, the Booster late intensity is lower than with slightly lower intensity Tandem beam. In this article, the authors present two experiments associated with the Booster injection efficiency and beam intensity. One experiment looks at the Booster injection efficiency by adjusting the Tandem beam intensity, and another looks at the beam life time while scraping the beam in the Booster. The studies suggest that the gold beam injection efficiency at the AGS Booster is related to the beam loss in the ring, rather than the intensity of injected beam or circulating beam. A close look at the effect of the lost gold ion at the Booster injection leads to the prediction that the lost gold ion creates large number of positive ions, and even larger number of electrons. The lost gold beam is also expected to create large numbers of neutral particles. In 1998 heavy ion run, the production of positive ions and electrons due to the lost gold beam has been observed. Also the high vacuum pressure due to the beam loss, presumably because of the neutral particles it created, has been measured. These results will be reported elsewhere.

ZHANG,S.Y.; AHRENS,L.A.

1998-06-22T23:59:59.000Z

406

Neutral Beam Injection for Plasma and Magnetic FieldDiagnostics  

DOE Green Energy (OSTI)

At the Lawrence Berkeley National Laboratory (LBNL) adiagnostic neutral beam injection system for measuring plasma parameters,flow velocity, and local magnetic field is being developed. High protonfraction and small divergence is essential for diagnostic neutral beams.In our design, a neutral hydrogen beam with an 8 cm x 11 cm (or smaller)elliptical beam spot at 2.5 m from the end of the extraction column isproduced. The beam will deliver up to 5 A of hydrogen beam to the targetwith a pulse width of ~;1 s, once every 1 - 2 min. The H1+ ion species ofthe hydrogen beamwill be over 90 percent. For this application, we havecompared two types of RF driven multicusp ion sources operating at 13.56MHz. The first one is an ion source with an external spiral antennabehind a dielectric RF-window. The second one uses an internal antenna insimilar ion source geometry. The source needs to generate uniform plasmaover a large (8 cm x 5 cm) extraction area. We expect that the ion sourcewith internal antenna will be more efficient at producing the desiredplasma density but might have the issue of limited antenna lifetime,depending on the duty factor. For both approaches there is a need forextra shielding to protect the dielectric materials from the backstreaming electrons. The source walls will be made of insulator materialsuch as quartz that has been observed to generate plasma with higheratomic fraction than sources with metal walls. The ion beam will beextracted and accelerated by a set of grids with slits, thus forming anarray of 6 sheet-shaped beamlets. The multiple grid extraction will beoptimized using computer simulation programs. Neutralization of the beamwill be done in neutralization chamber, which has over 70 percentneutralization efficiency.

Vainionpaa, Jaakko Hannes; Leung, Ka Ngo; Kwan, Joe W.; Levinton,Fred

2007-08-01T23:59:59.000Z

407

Experimental and Simulation Studies to Evaluate the Improvement of Oil Recovery by Different Modes of CO2 Injection in Carbonate Reservoirs  

E-Print Network (OSTI)

Experimental and numerical simulation studies were conducted to investigate the improvement of light oil recovery in carbonate cores during CO2 injection. The main steps in the study are as follows. First, the minimum miscibility pressure of 31ºAPI west Texas oil and CO2 was measured using the slimtube (miscibility) apparatus. Second, miscible CO2 coreflood experiments were carried out on different modes of injection such as CGI, WF, WAG, and SWAG. Each injection mode was conducted on unfractured and fractured cores. Fractured cores included two types of fracture systems creating two shape models on the core. Also, runs were made with different salinity levels for the injected water, 0 ppm, 60,000 ppm, and 200,000 ppm. Finally, based on the experimental results, a 2-D numerical simulation model was constructed and validated. The simulation model was then extended to conduct sensitivity studies on different parameters such as permeability variations in the core, WAG ratio and slug size, and SWAG ratio. The results of this study indicate that injecting water with CO2 either simultaneously or in alternating cycles increases the oil recovery by at least 10 percent and reduces the CO2 requirements by 50 percent. The salinity of the injected water has shown a detrimental effect on oil recovery only during WAG and SWAG injections. Lowering injected water salinity, which increases the CO2 solubility in water, increases oil recovery by up to 18 percent. Unfractured cores resulted in higher recovery than all fractured ones. CGI in fractured cores resulted in very poor recovery but WAG and SWAG injections improved the oil recovery by at least 25 percent over CGI. This is because of the better conformance provided by the injected water, which decreased CO2 cycling through the fracture. CO2 injection in layered permeability arrangements showed significant decrease in oil recovery (up to 40 percent) compared to the homogenous case. For all injection modes during the layered permeability arrangements, the best oil recovery was obtained when the flow barrier is in the middle of the core. When the permeability was arranged in sequence, each injection mode showed different preference to the permeability arrangements. The WAG ratio study in the homogenous case showed that a 1:2 ratio had the highest oil recovery, but the optimum ratio was 1:1 based on the amount of injected CO2. In contrast, layered permeability arrangements showed different WAG ratio preference depending on the location of the flow barrier.

Aleidan, Ahmed Abdulaziz S.

2010-12-01T23:59:59.000Z

408

NETL: News Release - Alabama Injection Project Aimed at Enhanced Oil  

NLE Websites -- All DOE Office Websites (Extended Search)

March 1, 2010 March 1, 2010 Alabama Injection Project Aimed at Enhanced Oil Recovery, Testing Important Geologic CO2 Storage DOE-Sponsored Citronelle Project Appears Ideal Location for Concurrent CO2 Sequestration and EOR Operations Washington, D.C. - Carbon dioxide (CO2) injection - an important part of carbon capture and storage (CCS) technology - is underway as part of a pilot study of CO2 enhanced oil recovery (EOR) in the Citronelle Field of Mobile County, Alabama. A project team led by the University of Alabama at Birmingham is conducting the injection. Study results of the 7,500-ton CO2 injection will provide estimates of oil yields from EOR and CO2 storage capacity in depleted oil reservoirs. In the United States, CO2 injection has already helped recover nearly 1.5 billion barrels of oil from mature oil fields, yet the technology has not been deployed widely. It is estimated that nearly 400 billion barrels of oil still remain trapped in the ground. Funded through the Department of Energy's Office of Fossil Energy, the primary goal of the Citronelle Project is to demonstrate that remaining oil can be economically produced using CO2-EOR technology in untested areas of the United States, thereby reducing dependency on oil imports, providing domestic jobs, and preventing the release of CO2 into the atmosphere.

409

Electric Power Research Institute Environmental Control Technology Center Report to the Steering Committee  

Science Conference Proceedings (OSTI)

Operations and maintenance continued this month at the Electric Power Research Institute's (EPRI?s) Environmental Control Technology Center (ECTC). Testing for the month involved the Dry Sorbent Injection (DSI) test block with the Carbon Injection System. Also, several installation activities were initiated this month for the testing of a new EPRI/ADA Technologies sorbent sampling system in December. The 1.0 MW Cold-Side Selective Catalytic Reduction (SCR) unit, the 0.4 MW Mini Pilot Wet Scrubber, and the 4.0 MW Pilot Wet Scrubber remained idle this month in a cold-standby mode and were inspected regularly. These units remain available for testing as future work is identified.

None

1997-11-01T23:59:59.000Z

410

CO2 Injection Begins in Illinois | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Begins in Illinois Begins in Illinois CO2 Injection Begins in Illinois November 17, 2011 - 12:00pm Addthis Washington, DC - The Midwest Geological Sequestration Consortium (MGSC), one of seven regional partnerships created by the U.S. Department of Energy (DOE) to advance carbon storage technologies nationwide, has begun injecting carbon dioxide (CO2) for their large-scale CO2 injection test in Decatur, Illinois. The test is part of the development phase of the Regional Carbon Sequestration Partnerships program, an Office of Fossil Energy initiative launched in 2003 to determine the best approaches for capturing and permanently storing gases that can contribute to global climate change. "Establishing long-term, environmentally safe and secure underground CO2 storage is a critical component in achieving successful commercial

411

Engines - Spark Ignition Engines - Direct Injection - Omnivorous Engine  

NLE Websites -- All DOE Office Websites (Extended Search)

Direct Injection, Spark-Ignited Engines Direct Injection, Spark-Ignited Engines Omnivorous Engine Omnivorous Engine Setup Omnivorous Engine Setup New engine technology has made possible engines that will operate on a wide variety of fuel inputs, from gasoline to naptha to ethanol to methanol, without driver intervention. Although flexible fuel vehicles have been produced in the millions, their engines have always been optimized for gasoline operation while accepting significant performance and efficiency degradations when using the alternative fuel. This project seeks to combine in-cylinder measurement technology, and advanced controls to optimize spark timing, the quantity and timing of injected fuel, to produce an "omnivorous engine"--one that will be able to run on any liquid spark ignition fuel with optimal efficiency and low

412

PHYSICS PROCESSES IN DISRUPTION MITIGATION USING MASSIVE NOBLE GAS INJECTION  

SciTech Connect

Methods for detecting imminent disruptions and mitigating disruption effects using massive injection of noble gases (He, Ne, or Ar) have been demonstrated on the DIII-D tokamak [1]. A jet of high injected gas density (> 10{sup 24} m{sup -3}) and pressure (> 20 kPa) penetrates the target plasma at the gas sound speed ({approx}300-500 m/s) and increases the atom/ion content of the plasma by a factor of > 50 in several milliseconds. UV line radiation from the impurity species distributes the plasma energy uniformly on the first wall, reducing the thermal load to the divertor by a factor of 10. Runaway electrons are almost completely eliminated by the large density of free and bound electrons supplied by the gas injection. The small vertical plasma displacement before current quench and high ratio of current decay rate to vertical growth rate result in a 75% reduction in peak halo current amplitude and attendant forces.

D.A. HUMPHREYS; D.G. WHYTE; T.C. JERNIGAN; T.E.EVANS; D.S. GRAY; E.M. HOLLMANN; A.W. HYATT; A.G. KELLMAN; C.J. LASNIER; P.B. PARKS; P.L. TAYLOR

2002-07-01T23:59:59.000Z

413

Numerical modeling of water injection into vapor-dominatedgeothermal reservoirs  

SciTech Connect

Water injection has been recognized as a powerful techniquefor enhancing energy recovery from vapor-dominated geothermal systemssuch as The Geysers. In addition to increasing reservoir pressures,production well flow rates, and long-term sustainability of steamproduction, injection has also been shown to reduce concentrations ofnon-condensible gases (NCGs) in produced steam. The latter effectimproves energy conversion efficiency and reduces corrosion problems inwellbores and surface lines.This report reviews thermodynamic andhydrogeologic conditions and mechanisms that play an important role inreservoir response to water injection. An existing general-purposereservoir simulator has been enhanced to allow modeling of injectioneffects in heterogeneous fractured reservoirs in three dimensions,including effects of non-condensible gases of different solubility.Illustrative applications demonstrate fluid flow and heat transfermechanisms that are considered crucial for developing approaches to insitu abatement of NCGs.

Pruess, Karsten

2006-11-06T23:59:59.000Z

414

Steam-injection profile control using limited-entry perforations  

SciTech Connect

A completion technique for steam-injection wells that ensures improved profile distribution of steam into several independent sands is being used at the South Belridge field in California. Previously, steam profiles were poor for many of the conventionally perforated (two 3/8-in. (9.5-mm) -diameter holes per foot) injection wells. This standard completion does not guarantee that the thicker, higher-permeability sands will not act as thief zones with respect to the thinner, tighter sands open in the same wellbore. Limited-entry perforating (typically one hole per 15 to 20 ft (4.6 to 6.1m) of gross interval with at least one in each major sand member) provides the best assurance of achieving a uniform injection profile in single-wellbore multisand completions.

Small, G.P.

1986-09-01T23:59:59.000Z

415

Steam-injection profile control using limited-entry perforations  

Science Conference Proceedings (OSTI)

A completion technique for steam injection wells that assures improved profile distribution of steam into several independent sands is being used at the South Belridge Field, California. Previously, steam profiles were poor for many of the conventionally perforated (two-3/8'' diameter holes per foot) injection wells. This standard completion does not guarantee that the thicker, higher permeability sands will not act as thief zones with respect to the thinner, tighter sands open in the same wellbore. Limited entry perforating (typically one hole per 15-20' of gross interval with at least one in each major sand member) provides the best assurance of achieving a uniform injection profile in single wellbore multi-sand completions.

Small, G.P.

1985-03-01T23:59:59.000Z

416

First results on disruption mitigation by massive gas injection in Korea Superconducting Tokamak Advanced Research  

Science Conference Proceedings (OSTI)

Massive gas injection (MGI) system was developed on Korea Superconducting Tokamak Advanced Research (KSTAR) in 2011 campaign for disruption studies. The MGI valve has a volume of 80 ml and maximum injection pressure of 50 bar, the diameter of valve orifice to vacuum vessel is 18.4 mm, the distance between MGI valve and plasma edge is {approx}3.4 m. The MGI power supply employs a large capacitor of 1 mF with the maximum voltage of 3 kV, the valve can be opened in less than 0.1 ms, and the amount of MGI can be controlled by the imposed voltage. During KSTAR 2011 campaign, MGI disruptions are carried out by triggering MGI during the flat top of circular and limiter discharges with plasma current 400 kA and magnetic field 2-3.5 T, deuterium injection pressure 39.7 bar, and imposed voltage 1.1-1.4 kV. The results show that MGI could mitigate the heat load and prevent runaway electrons with proper MGI amount, and MGI penetration is deeper under higher amount of MGI or lower magnetic field. However, plasma start-up is difficult after some of D{sub 2} MGI disruptions due to the high deuterium retention and consequently strong outgassing of deuterium in next shot, special effort should be made to get successful plasma start-up after deuterium MGI under the graphite first wall.

Yu Yaowei [National Fusion Research Institute, Daejeon 305-806 (Korea, Republic of); Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Kim, Young-Ok; Kim, Hak-Kun; Kim, Hong-Tack; Kim, Woong-Chae; Kim, Kwang-Pyo; Son, Soo-Hyun; Bang, Eun-Nam; Hong, Suk-Ho; Yoon, Si-Woo [National Fusion Research Institute, Daejeon 305-806 (Korea, Republic of); Zhuang Huidong [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Chen Zhongyong [Huazhong University of Science and Technology, Wuhan 430074 (China)

2012-12-15T23:59:59.000Z

417

Human Collagen Injections to Reduce Rectal Dose During Radiotherapy  

Science Conference Proceedings (OSTI)

Objectives: The continuing search for interventions, which address the incidence and grade of rectal toxicities associated with radiation treatment of prostate cancer, is a major concern. We are reporting an investigational trial using human collagen to increase the distance between the prostate and anterior rectal wall, thereby decreasing the radiation dose to the rectum. Methods: This is a pilot study evaluating the use of human collagen as a displacing agent for the rectal wall injected before starting a course of intensity-modulated radiotherapy (IMRT) for prostate cancer. Using a transperineal approach, 20 mL of human collagen was injected into the perirectal space in an outpatient setting. Computerized IMRT plans were performed pre- and postcollagen injection, and after a patient completed their radiotherapy, to determine radiation dose reduction to the rectum associated with the collagen injection. Computed tomography scans were performed 6 months and 12 months after completing their radiotherapy to evaluate absorption rate of the collagen. All patients were treated with IMRT to a dose of 75.6 Gy to the prostate. Results: Eleven patients were enrolled into the study. The injection of human collagen in the outpatient setting was well tolerated. The mean separation between the prostate and anterior rectum was 12.7 mm. The mean reduction in dose to the anterior rectal wall was 50%. All men denied any rectal symptoms during the study. Conclusions: The transperineal injection of human collagen for the purpose of tissue displacement is well tolerated in the outpatient setting. The increased separation between the prostate and rectum resulted in a significant decrease in radiation dose to the rectum while receiving IMRT and was associated with no rectal toxicities.

Noyes, William R., E-mail: noyes@cancercenternd.com [Department of Radiation Oncology, Cancer Center of North Dakota, Grand Forks, ND (United States); Hosford, Charles C. [Department of Medical Statistics, University of North Dakota School of Medicine, Grand Forks, ND (United States); Schultz, Steven E. [Department of Urology, RiverView Health, Grand Forks, ND (United States)

2012-04-01T23:59:59.000Z

418

HIGH RESOLUTION PREDICTION OF GAS INJECTION PROCESS PERFORMANCE FOR HETEROGENEOUS RESERVOIRS  

Science Conference Proceedings (OSTI)

Gas injection in oil reservoirs offers huge potential for improved oil recovery. However, successful design of a gas injection process requires a detailed understanding of a variety of different significant processes, including the phase behavior of multicomponent mixtures and the approach to multi-contact miscibility in the reservoir, the flow of oil, water and gas underground, and the interaction of phase behavior reservoir heterogeneity and gravity on overall performance at the field scale. This project attempts to tackle all these issues using a combination of theoretical, numerical and laboratory studies of gas injection. The aim of this work is to develop a set of ultra-fast compositional simulation tools that can be used to make field-scale predictions of the performance of gas injection processes. To achieve the necessary accuracy, these tools must satisfy the fundamental physics and chemistry of the displacement from the pore to the reservoir scales. Thus this project focuses on four main research areas: (1) determination of the most appropriate methods of mapping multicomponent solutions to streamlines and streamtubes in 3D; (2) development of techniques for automatic generation of analytical solutions for one-dimensional flow along a streamline; (3) experimental investigations to improve the representation of physical mechanisms that govern displacement efficiency along a streamline; and (4) Theoretical and experimental investigations to establish the limitations of the streamline/streamtube approach. In this report they briefly review the status of the research effort in each area. They then give a more in depth discussion of the development of a CT scanning technique which can measure compositions in a two-phase, three-component system in-situ.

Thomas A. Hewett; Franklin M. Orr Jr.

2000-12-31T23:59:59.000Z

419

Negative ion-based neutral injection on DIII-D  

SciTech Connect

High energy negative ion-based neutral beam injection is a strong candidate for heating and non-inductive current drive in tokamaks. Many of the questions related to the physics and engineering of this technique remain unanswered. In this paper, we consider the possibility of negative ion-based neutral beam injection on DIII-D. We establish the desired parameter space by examining physics trades. This is combined with potential design constraints and a survey of component technology options to establish an injector concept. Injector performance is estimated assuming particular component technologies, and concept flexibility with respect to incorporating alternate technologies is described. 9 refs., 6 figs., 4 tabs.

Stewart, L.D.; Bhadra, D.K.; Colleraine, A.P.; Kim, J.

1990-01-01T23:59:59.000Z

420

Charge - dependent increase in coherence of synchrotron oscillation at injection  

SciTech Connect

Because of coupled bunch instability and/or because of some unidentified mechanism, bunches from the 8 GeV Booster accelerator at Fermilab arrive in the Main Injector synchrotron with a complicated centroid distribution in phase and energy. The currently installed broad band kicker provides a maximum of 2 kV, insufficient to remove injection errors before the oscillations would de-cohere, ignoring the influence of bunch charge. Perhaps surprisingly, for sufficient but generally modest charge, the effect of potential well distortion is to maintain bunch integrity. This talk illustrates the phenomenon for injection into the Fermilab Main Injector and offers an explanation sufficiently general to apply elsewhere.

MacLachlan, J.A.; /Fermilab

2004-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "injection dsi systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Blue light emitting diode internal and injection efficiency  

Science Conference Proceedings (OSTI)

A simple experimental method of light emitting diode(LED) injection efficiency (IE) determination was suggested. IE and internal quantum efficiency(IQE) calculation is an actual and difficult problem in LED science. In this paper IE and IQE of blue LEDs were determined separately. The method is based on electroluminescence data fitting by the modified rate equation model. Efficiency droop caused by Auger recombination and poor injection were taken into account. Only one reasonable assumption was accepted during the calculations: IE tends to 1 at low current densities.

Ilya E. Titkov; Denis A. Sannikov; Young-Min Park; Joong-Kon Son

2012-01-01T23:59:59.000Z

422

Conditioning of geothermal brine effluents for injection: use of coagulants  

DOE Green Energy (OSTI)

The use of various chemical coagulants and flocculants with spent geothermal brine for enhancing the removal of colloidal solids prior to injection was studied. Brine at 80 to 85/sup 0/C was obtained from the injection line of the SDG and E/DOE Geothermal Loop Experimental Facility during a period of operation with Magmamax No. 1 Fluid. The solids consist primarily of an iron-rich amorphous silica and heavy metal sulfides, principally lead. Standard jar testing equipment was used to carry out the tests.

Quong, R.; Shoepflin, F.; Stout, N.D.

1978-02-01T23:59:59.000Z

423

High-resolution seismic studies applied to injected geothermal fluids  

DOE Green Energy (OSTI)

The application of high-resolution microseismicity studies to the problem of monitoring injected fluids is one component of the Geothermal Injection Monitoring Project at LLNL. The evaluation of microseismicity includes the development of field techniques, and the acquisition and processing of events during the initial development of a geothermal field. To achieve a specific detection threshold and location precision, design criteria are presented for seismic networks. An analysis of a small swarm near Mammoth Lakes, California, demonstrates these relationships and the usefulness of high-resolution seismic studies. A small network is currently monitoring the Mammoth-Pacific geothermal power plant at Casa Diablo as it begins production.

Smith, A.T.; Kasameyer, P.

1985-01-01T23:59:59.000Z

424

Effect of Temperature on NOx Reduction by Nitrogen Atom Injection  

DOE Green Energy (OSTI)

Chemical reduction of NO{sub x} can be accomplished by injection of nitrogen atoms into the diesel engine exhaust stream. The nitrogen atoms can be generated from a separate stream of pure N{sub 2} by means of plasma jets or non-thermal plasma reactors. This paper examines the effect of exhaust temperature on the NO{sub x} reduction efficiency that can be achieved by nitrogen atom injection. It is shown that to achieve a high NO{sub x} reduction efficiency at a reasonable power consumption penalty, the exhaust temperature needs to be 100 C or less.

Penetrante, B

1999-10-28T23:59:59.000Z

425

Boiling Water Reactor (BWR) Zinc Injection Strategy Evaluation  

Science Conference Proceedings (OSTI)

All U.S. boiling water reactors (BWRs) inject depleted zinc oxide (DZO) into the reactor feedwater for the purpose of suppressing drywell shutdown radiation dose rates. Current guidance in BWRVIP-190: BWR Vessel and Internals Project, BWR Water Chemistry Guidelines2008 Revision (EPRI report 1016579) is to inject sufficient zinc to achieve a Co-60(s)/Zn(s) ratio of Utility-specific goals may encourage even lower Co-60(s)/Zn(s) levels. This may be in part because BWR e...

2010-11-24T23:59:59.000Z

426

Optimization of beam injection into the first accelerating module at TTF with cavity dipole mode signals  

E-Print Network (OSTI)

Optimization of beam injection into the first accelerating module at TTF with cavity dipole mode signals

Baboi, N; Kreps, G; McCormick, D; Napoly, O; Paparella, R G; Ross, M; Schlarb, H; Smith, T; Wendt, M

2005-01-01T23:59:59.000Z

427

The application of high frequency seismic monitoring methods for the mapping of fluid injections  

DOE Green Energy (OSTI)

This paper describes experimental work using seismic methods for monitoring the path of fluid injections. The most obvious application is the high pressure fluid injections for the purpose of hydrofracturing. Other applications are the injection of grout into shallow subsurface structures and the disposal of fluids in the geothermal and toxic waste industries. In this paper hydrofracture monitoring and grout injections will be discussed.

Majer, E.L.

1987-04-01T23:59:59.000Z

428

Diffusion of a plasma subject to neutral beam injection  

SciTech Connect

Two-dimensional numerical plasma simulations have been carried out in a uniform magnetic field to study the effects of neutral beam injection on plasma diffusion. Neutral beams injected across a magnetic field are assumed to be ionized by various ionization processes in a plasma. It is found that the suprathermal convective motion of a plasma generated by the injection of neutral beams is dissipated via anomalous viscosity, leading to enhanced cross-field diffusion. The diffusion coefficient depends weakly on the magnetic field and plasma density, similar to the diffusion due to thermally excited convective cells. The magnitude of the diffusion increases with the injection energy and is much larger than the thermal diffusion because of the presence of suprathermal plasma convection. It is shown that a similar anomalous plasma diffusion may occur in a plasma subject to radio frequency (RF) wave heating where only a localized region of plasma across a magnetic field is heated to a temperature much higher than the surrounding temperature. Theoretical investigations are given on the scaling of enhanced plasma diffusion.

Okuda, H.; Hiroe, S.

1986-10-01T23:59:59.000Z

429

Optical Diagnostics and Direct Injection of Liquid Fuel Sprays  

Science Conference Proceedings (OSTI)

The research described here addresses the problem of a paucity of high quality data on the full field structure of high pressure liquid fuel sprays for gasoline direct injection, GDI, engines. The paper describes the application of phase Doppler anemometry, ... Keywords: GDI, PDA, laser sheet, spray, visualisation

G. K. Hargrave; G. Wigley; J. Allen; A. Bacon

1999-12-01T23:59:59.000Z

430

Highly efficient 6-stroke engine cycle with water injection  

Science Conference Proceedings (OSTI)

A six-stroke engine cycle having improved efficiency. Heat is recovered from the engine combustion gases by using a 6-stroke engine cycle in which combustion gases are partially vented proximate the bottom-dead-center position of the fourth stroke cycle, and water is injected proximate the top-dead-center position of the fourth stroke cycle.

Szybist, James P; Conklin, James C

2012-10-23T23:59:59.000Z

431

Influence of spectral width on power fluctuations of injection lasers  

SciTech Connect

An experimental investigation was made of the noise of AlGaAs injection lasers in the 10--100 MHz frequency range. It was found that under steady-state conditions the fluctuation level is governed by the width of the laser emission spectrum.

Bessonov, Y.L.; Kurlenkov, S.S.; Morozov, V.N.; Sapozhnikov, S.M.; Thai, C.t.; Shidlovskii, V.P.

1985-02-01T23:59:59.000Z

432

Intracluster gas pressure, entropy injection and redshift evolution  

E-Print Network (OSTI)

We study the effect of entropy injection in the intracluster medium (ICM) in light of the recent observationally determined universal pressure profile of the ICM. Beginning with a power-law entropy profile that is expected in the absence of any feedback, we show that a simple universal prescription of entropy injection results in the final, observed universal pressure profile. This simple prescription has two components, one associated with an overall increase in entropy and another associated with injection in the central parts of the cluster. Importantly, both the components of entropy injection are needed to produce the final universal pressure profile. This is indicative of a need of both preheating the ICM as well {\\it in situ} AGN/SNe heating. We demonstrate the usefulness of the method by extending the calculations to clusters at high redshift, and predict redshift evolution of cluster scaling relations that can be tested against data. We show that the self-similar evolution of the universal pressure p...

Nath, Biman B

2011-01-01T23:59:59.000Z

433

Development of Improved Oil Field Waste Injection Disposal Techniques  

Science Conference Proceedings (OSTI)

The goals of this DOE sponsored project are to: (1) assemble and analyze a comprehensive database of past waste injection operations; (2) develop improved diagnostic techniques for monitoring fracture growth and formation changes; (3) develop operating guidelines to optimize daily operations and ultimate storage capacity of the target formation; and (4) to test these improved models and guidelines in the field.

Terralog Technologies USA Inc.

2001-12-17T23:59:59.000Z

434

Applications of geochemistry to problems in geothermal injection  

DOE Green Energy (OSTI)

Conventional reservoir engineering studies have, in the past, dealt mainly with interpretation of pressure transient effects in a reservoir. Present-day techniques can be used in many reservoirs to forecast with some reliability the probability, magnitude and timing of pressure interference among wells. However, forecasting fluid breakthrough from an injection well to a production well in geologically complex geothermal reservoirs is not presently possible with any reliability, and forecasting thermal breakthrough is even more difficult. In addition, the chemical effects of injection are poorly understood at present, and it is not possible to predict beforehand the full range of scaling and aquifer plugging problems that may be encountered. This report discusses development of chemical tracers specifically designed for geothermal applications so that breakthrough of injectate can be detected early, and field and laboratory studies on the chemical interactions among reservoir fluids, reservoir rocks and injected fluids so that these interactions can be quantified and models developed for predicting any degradation (or enhancement) of permeability.

Wright, P.M.

1985-02-01T23:59:59.000Z

435

Processing of high salinity brines for subsurface injection  

DOE Green Energy (OSTI)

Different chemical pretreatments and filtration methods were evaluated as a possible means of clarifying and improving the injectivity of hypersaline brines. Six different downflow media combinations were evaluated over three geopressurized sites, using test data from 4 inch diameter filters. Also, tests were conducted with one hollow fiber ultrafilter unit and two types of disposable cartridge filters. The test procedures are mentioned briefly. (MHR)

Thompson, R.E.; Raber, E.

1979-08-06T23:59:59.000Z

436

DISRUPTION MITIGATION WITH HIGH-PRESSURE NOBLE GAS INJECTION  

Science Conference Proceedings (OSTI)

OAK A271 DISRUPTION MITIGATION WITH HIGH-PRESSURE NOBLE GAS INJECTION. High-pressure gas jets of neon and argon are used to mitigate the three principal damaging effects of tokamak disruptions: thermal loading of the divertor surfaces, vessel stress from poloidal halo currents and the buildup and loss of relativistic electrons to the wall. The gas jet penetrates as a neutral species through to the central plasma at its sonic velocity. The injected gas atoms increase up to 500 times the total electron inventory in the plasma volume, resulting in a relatively benign radiative dissipation of >95% of the plasma stored energy. The rapid cooling and the slow movement of the plasma to the wall reduce poloidal halo currents during the current decay. The thermally collapsed plasma is very cold ({approx} 1-2 eV) and the impurity charge distribution can include > 50% fraction neutral species. If a sufficient quantity of gas is injected, the neutrals inhibit runaway electrons. A physical model of radiative cooling is developed and validated against DIII-D experiments. The model shows that gas jet mitigation, including runaway suppression, extrapolates favorably to burning plasmas where disruption damage will be more severe. Initial results of real-time disruption detection triggering gas jet injection for mitigation are shown.

WHYTE, DG; JERNIGAN, TC; HUMPHREYS, DA; HYATT, AW; LASNIER, CJ; PARKS, PB; EVANS, TE; TAYLOR, PL; KELLMAN, AG; GRAY, DS; HOLLMANN, EM

2002-10-01T23:59:59.000Z

437

Development of Improved Oil Field Waste Injection Disposal Techniques  

Science Conference Proceedings (OSTI)

The goals of this project have was to: (1) assemble and analyze a comprehensive database of past waste injection operations; (2) develop improved diagnostic techniques for monitoring fracture growth and formation changes; (3) develop operating guidelines to optimize daily operations and ultimate storage capacity of the target formation; and (4) to apply these improved models and guidelines in the field.

Terralog Technologies

2002-11-25T23:59:59.000Z

438

NOx reduction by electron beam-produced nitrogen atom injection  

DOE Patents (OSTI)

Deactivated atomic nitrogen generated by an electron beam from a gas stream containing more than 99% N.sub.2 is injected at low temperatures into an engine exhaust to reduce NOx emissions. High NOx reduction efficiency is achieved with compact electron beam devices without use of a catalyst.

Penetrante, Bernardino M. (San Ramon, CA)

2002-01-01T23:59:59.000Z

439

Monte Carlo simulation of neutral beam injection into fusion reactors  

SciTech Connect

Motivations and techniques for the Monte Carlo computer simulation of energetic neutral beam injection for fusion reactors are described. The versatility of this approach allows a significantly more sophisticated treatment of charge transfer collision phenomena and consequent effects on engineering design than available from prior work. Exemplary results for a mirror Fusion Engineering Research Facility (FERF) are discussed. (auth)

Miller, R.L.

1975-09-15T23:59:59.000Z

440

Injection/withdrawal scheduling for natural gas storage facilities  

Science Conference Proceedings (OSTI)

Control decisions for gas storage facilities are made in the face of extreme uncertainty over future natural gas prices on world markets. We examine the problem faced by owners of storage contracts of how to manage the injection/withdrawal schedule of ... Keywords: natural gas storage, optimization, scheduling

Alan Holland

2007-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "injection dsi systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Reservoir response to injection in the Southeast Geysers  

DOE Green Energy (OSTI)

A 20 megawatt (MW) increase in steam flow potential resulted within five months of the start-up of new injection wells in the Southeast Geysers. Flow rate increases were observed in 25 wells offset to the injectors, C-11 and 956A-1. This increased flowrate was sustained during nine months of continuous injection with no measurable decrease in offset well temperature until C-11 was shut-in due to wellbore bridging. The responding steam wells are located in an area of reduced reservoir steam pressure known as the Low Pressure Area (LPA). The cause of the flowrate increases was twofold (1) an increase in static reservoir pressure and (2) a decrease in interwell communication. Thermodynamic and microseismic evidence suggests that most of the water is boiling near the injector and migrating to offset wells located ''down'' the static pressure gradient. However, wells showing the largest increase in steam flowrate are not located at the heart of the pressure sink. This indicates that localized fracture distribution controls the preferred path of fluid migration from the injection well. A decrease in non-condensible gas concentrations was also observed in certain wells producing injection derived steam within the LPA. The LPA project has proven that steam suppliers can work together and benefit economically from joint efforts with the goal of optimizing the use of heat from The Geysers reservoir. The sharing of costs and information led directly to the success of the project and introduces a new era of increased cooperation at The Geysers.

Enedy, Steve; Enedy, Kathy; Maney, John

1991-01-01T23:59:59.000Z

442

Lower 48 States Total Natural Gas Injections into Underground Storage  

U.S. Energy Information Administration (EIA) Indexed Site

Total Natural Gas Injections into Underground Storage (Million Cubic Feet) Total Natural Gas Injections into Underground Storage (Million Cubic Feet) Lower 48 States Total Natural Gas Injections into Underground Storage (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 2011 50,130 81,827 167,632 312,290 457,725 420,644 359,267 370,180 453,548 436,748 221,389 90,432 2012 74,854 56,243 240,351 263,896 357,965 323,026 263,910 299,798 357,109 327,767 155,554 104,953 2013 70,592 41,680 99,330 270,106 465,787 438,931 372,458 370,471 418,848 - = No Data Reported; -- = Not Applicable; NA = Not Available; W = Withheld to avoid disclosure of individual company data. Release Date: 12/12/2013 Next Release Date: 1/7/2014 Referring Pages: Injections of Natural Gas into Underground Storage - All Operators

443

Compendium of regulatory requirements governing underground injection of drilling waste.  

Science Conference Proceedings (OSTI)

Large quantities of waste are produced when oil and gas wells are drilled. The two primary types of drilling wastes include used drilling fluids (commonly referred to as muds), which serve a variety of functions when wells are drilled, and drill cuttings (rock particles ground up by the drill bit). Some oil-based and synthetic-based muds are recycled; other such muds, however, and nearly all water-based muds, are disposed of. Numerous methods are employed to manage drilling wastes, including burial of drilling pit contents, land spreading, thermal processes, bioremediation, treatment and reuse, and several types of injection processes. This report provides a comprehensive compendium of the regulatory requirements governing the injection processes used for disposing of drilling wastes; in particular, for a process referred to in this report as slurry injection. The report consists of a narrative discussion of the regulatory requirements and practices for each of the oil- and gas-producing states, a table summarizing the types of injection processes authorized in each state, and an appendix that contains the text of many of the relevant state regulations and policies. The material included in the report was derived primarily from a review of state regulations and from interviews with state oil and gas regulatory officials.

Puder, M. G.; Bryson, B.; Veil, J. A.

2002-11-08T23:59:59.000Z

444

Coal-fueled diesel technology development -- Fuel injection equipment for coal-fueled diesel engines  

DOE Green Energy (OSTI)

Because of the abrasive and corrosive nature of coal water slurries, the development of coal-fueled diesel engine technology by GE-Transportation Systems (GE-TS) required special fuel injection equipment. GE-Corporate Research and Development (GE-CRD) undertook the design and development of fuel injectors, piston pumps, and check valves for this project. Components were tested at GE-CRD on a simulated engine cylinder, which included a cam-actuated jerk pump, prior to delivery to GE-TS for engine testing.

Johnson, R.N.; Hayden, H.L.

1994-01-01T23:59:59.000Z

445

Experimental and computational studies of film cooling with compound angle injection  

DOE Green Energy (OSTI)

The thermal efficiency of gas turbine systems depends largely on the turbine inlet temperature. Recent decades have seen a steady rise in the inlet temperature and a resulting reduction in fuel consumption. At the same time, it has been necessary to employ intensive cooling of the hot components. Among various cooling methods, film cooling has become a standard method for cooling of the turbine airfoils and combustion chamber walls. The University of Minnesota program is a combined experimental and computational study of various film-cooling configurations. Whereas a large number of parameters influence film cooling processes, this research focuses on compound angle injection through a single row and through two rows of holes. Later work will investigate the values of contoured hole designs. An appreciation of the advantages of compound angle injection has risen recently with the demand for more effective cooling and with improved understanding of the flow; this project should continue to further this understanding. Approaches being applied include: (1) a new measurement system that extends the mass/heat transfer analogy to obtain both local film cooling and local mass (heat) transfer results in a single system, (2) direct measurement of three-dimensional turbulent transport in a highly-disturbed flow, (3) the use of compound angle and shaped holes to optimize film cooling performance, and (4) an exploration of anisotropy corrections to turbulence modeling of film cooling jets.

Goldstein, R.J.; Eckert, E.R.G.; Patankar, S.V.; Simon, T.W. [Univ. of Minnesota, Minneapolis, MN (United States). Dept. of Mechanical Engineering

1995-12-31T23:59:59.000Z

446

Influence of Thermalisation on Electron Injection in Supernova Remnant Shocks  

E-Print Network (OSTI)

Within a test-particle description of the acceleration process in parallel nonrelativistic shocks, we present an analytic treatment of the electron injection. We estimate the velocity distribution of the injected electrons as the product of the post-shock thermal distribution of electrons times the probability for electrons with a given velocity to be accelerated; the injection efficiency is then evaluated as the integral of this velocity distribution. We estimate the probability of a particle to be injected as that of going back to the upstream region at least once. This is the product of the probability of returning to the shock from downstream times that of recrossing the shock from downstream to upstream. The latter probability is expected to be sensitive to details of the process of electron thermalisation within the (collisionless) shock, a process that is poorly known. In order to include this effect, for our treatment we use results of a numerical, fully kinetic study, by Bykov & Uvarov (1999). According to them, the probability of recrossing depends on physics of thermalisation through a single free parameter (Gamma), which can be expressed as a function of the Mach number of the shock, of the level of electron-ion equilibration, as well as of the spectrum of turbulence. It becomes apparent, from our analysis, that the injection efficiency is related to the post-shock electron temperature, and that it results from the balance between two competing effects: the higher the electron temperature, the higher the fraction of downstream electrons with enough velocity to return to the shock and thus to be ready to cross the shock from downstream to upstream; at the same time, however, the higher the turbulence, which would hinder the crossing.

O. Petruk; R. Bandiera

2006-06-05T23:59:59.000Z

447

TRACER STABILITY AND CHEMICAL CHANGES IN AN INJECTED GEOTHERMAL FLUID DURING INJECTION-BACKFLOW TESTING AT THE EAST MESA GEOTHERMAL FIELD  

DOE Green Energy (OSTI)

The stabilities of several tracers were tested under geothermal conditions while injection-backflow tests were conducted at East Mesa. The tracers I and Br were injected continuously while SCN (thiocyanate), B, and disodium fluorescein were each injected as a point source (slug). The tracers were shown to be stable, except where the high concentrations used during slug injection induced adsorption of the slug tracers. However, adsorption of the slug tracers appeared to ''armor'' the formation against adsorption during subsequent tests. Precipitation behavior of calcite and silica as well as Na/K shifts during injection are also discussed.

Adams, M.C.

1985-01-22T23:59:59.000Z

448

Supersonic combustion of a transverse injected H sub 2 jet in a radio frequency heated flow  

DOE Green Energy (OSTI)

The combustion of a single hydrogen jet, normally injected into a radio frequency (RF) heated, oxidant-containing, supersonic flow, has been established to characterize the chemical and fluid dynamic phenomena associated with the reaction process and ultimately validate the predictive capability of computational computer dynamic (CFD) codes. The experimental system employed for this study is unique in that it uses an electrodeless, inductively coupled plasma tube to generate the high temperature oxidant-containing gas for subsequent nozzle expansion. Advantages of an RF heated flow system include reduced free-stream chemical contamination, continuous operation, and relative ease of integration into a typical flow laboratory environment. A description of the system utilized for this study is presented including preliminary results of the reactive flow characterization. In addition, the use of the laser-based diagnostic techniques, such as planar laser-induced fluorescence (PLIF), for measuring flow properties is also discussed. 8 refs., 7 figs.

Wantuck, P.J.; Tennant, R.A.; Watanabe, H.H.

1991-01-01T23:59:59.000Z

449

Numerical Simulation of Injectivity Effects of Mineral Scaling and Clay Swelling in a Fractured Geothermal Reservoir  

DOE Green Energy (OSTI)

A major concern in the development of hot dry rock (HDR) and hot fractured rock (HFR) reservoirs is achieving and maintaining adequate injectivity, while avoiding the development of preferential short-circuiting flow paths such as those caused by thermally-induced stress cracking. Past analyses of HDR and HFR reservoirs have tended to focus primarily on the coupling between hydrology (flow), heat transfer, and rock mechanics. Recent studies suggest that rock-fluid interactions and associated mineral dissolution and precipitation effects could have a major impact on the long-term performance of HFR reservoirs. The present paper uses recent European studies as a starting point to explore chemically-induced effects of fluid circulation in HFR systems. We examine ways in which the chemical composition of reinjected waters can be modified to improve reservoir performance by maintaining or even enhancing injectivity. Chemical manipulations considered here include pH modification and dilution with fresh water. We performed coupled thermo-hydrologic-chemical simulations in which the fractured medium was represented by a one-dimensional MINC model (multiple interacting continua), using the non-isothermal multi-phase reactive geochemical transport code TOUGHREACT. Results indicate that modifying the injection water chemistry can enhance mineral dissolution and reduce clay swelling. Chemical interactions between rocks and fluids will change a HFR reservoir over time, with some changes favorable and others not. A detailed, quantitative understanding of processes and mechanisms can suggest chemical methods for reservoir management, which may be employed to improve the performance of the geothermal system.

Xu, Tianfu; Pruess, Karsten

2004-05-10T23:59:59.000Z

450

Cyclotron axial ion-beam-buncher system  

DOE Patents (OSTI)

Adiabatic ion bunching is achieved in a cyclotron axial ion injection system through the incorporation of a radio frequency quadrupole system, which receives ions from an external ion source via an accelerate-decelerate system and a focusing einzel lens system, and which adiabatically bunches and then injects the ions into the median plane of a cyclotron via an electrostatic quadrupole system and an inflection mirror.

Hamm, R.W.; Swenson, D.A.; Wangler, T.P.

1982-02-11T23:59:59.000Z

451

An experimental study of fuel injection strategies in CAI gasoline engine  

Science Conference Proceedings (OSTI)

Combustion of gasoline in a direct injection controlled auto-ignition (CAI) single-cylinder research engine was studied. CAI operation was achieved with the use of the negative valve overlap (NVO) technique and internal exhaust gas re-circulation (EGR). Experiments were performed at single injection and split injection, where some amount of fuel was injected close to top dead centre (TDC) during NVO interval, and the second injection was applied with variable timing. Additionally, combustion at variable fuel-rail pressure was examined. Investigation showed that at fuel injection into recompressed exhaust fuel reforming took place. This process was identified via an analysis of the exhaust-fuel mixture composition after NVO interval. It was found that at single fuel injection in NVO phase, its advance determined the heat release rate and auto-ignition timing, and had a strong influence on NO{sub X} emission. However, a delay of single injection to intake stroke resulted in deterioration of cycle-to-cycle variability. Application of split injection showed benefits of this strategy versus single injection. Examinations of different fuel mass split ratios and variable second injection timing resulted in further optimisation of mixture formation. At equal share of the fuel mass injected in the first injection during NVO and in the second injection at the beginning of compression, the lowest emission level and cyclic variability improvement were observed. (author)

Hunicz, J.; Kordos, P. [Department of Combustion Engines and Transport, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin (Poland)

2011-01-15T23:59:59.000Z

452

Engines - Fuel Injection and Spray Research - Gasoline Sprays  

NLE Websites -- All DOE Office Websites (Extended Search)

Gasoline Sprays Gasoline Sprays Animated image of fuel emerging from a gasoline injector Animated image of fuel emerging from a gasoline injector (simulated environment). Some newer automobiles in the U.S. use gasoline direct injection (GDI) engines. These advanced gasoline engines inject the fuel directly into the engine cylinder rather than into the intake port. These engines can achieve higher fuel efficiency, but they depend on a precise fuel/air mixture at the spark plug to initiate ignition. This leads to more stringent requirements on spray quality and reproducibility. GDI also enables new combustion strategies for gasoline engines such as lean burn engines that use less fuel and air. Lean burn engines may achieve efficiencies near those of diesels while producing low emissions. This

453

CO2 Injection in Kansas Oilfield Could Greatly Increase Production,  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

in Kansas Oilfield Could Greatly Increase Production, in Kansas Oilfield Could Greatly Increase Production, Permanently Store Carbon Dioxide, DOE Study Says CO2 Injection in Kansas Oilfield Could Greatly Increase Production, Permanently Store Carbon Dioxide, DOE Study Says August 31, 2011 - 1:00pm Addthis Washington, DC - The feasibility of using carbon dioxide (CO2) injection for recovering between 250 million and 500 million additional barrels of oil from Kansas oilfields has been established in a study funded by the U.S. Department of Energy (DOE). The University of Kansas Center for Research studied the possibility of near-miscible CO2 flooding for extending the life of mature oilfields in the Arbuckle Formation while simultaneously providing permanent geologic storage of carbon dioxide, a major greenhouse gas.

454

Apparatus and method for controlling the secondary injection of fuel  

SciTech Connect

A combustor (28) for a gas turbine engine is provided comprising a primary combustion chamber (30) for combusting a first fuel to form a combustion flow stream (50) and a transition piece (32) located downstream from the primary combustion chamber (30). The transition piece (32) comprises a plurality of injectors (66) located around a circumference of the transition piece (32) for injecting a second fuel into the combustion flow stream (50). The injectors (66) are effective to create a radial temperature profile (74) at an exit (58) of the transition piece (32) having a reduced coefficient of variation relative to a radial temperature profile (64) at an inlet (54) of the transition piece (32). Methods for controlling the temperature profile of a secondary injection are also provided.

Martin, Scott M.; Cai, Weidong; Harris, Jr., Arthur J.

2013-03-05T23:59:59.000Z

455

BOILING WATER REACTOR WITH FEED WATER INJECTION NOZZLES  

DOE Patents (OSTI)

This patent covers the use of injection nozzles for pumping water into the lower ends of reactor fuel tubes in which water is converted directly to steam. Pumping water through fuel tubes of this type of boiling water reactor increases its power. The injection nozzles decrease the size of pump needed, because the pump handles only the water going through the nozzles, additional water being sucked into the tubes by the nozzles independently of the pump from the exterior body of water in which the fuel tubes are immersed. The resulting movement of exterior water along the tubes holds down steam formation, and thus maintains the moderator effectiveness, of the exterior body of water. (AEC)

Treshow, M.

1963-04-30T23:59:59.000Z

456

IN SITU DECOMMISSIONING SENSOR NETWORK, MESO-SCALE TEST BED - PHASE 3 FLUID INJECTION TEST SUMMARY REPORT  

SciTech Connect

The DOE Office of Environmental management (DOE EM) faces the challenge of decommissioning thousands of excess nuclear facilities, many of which are highly contaminated. A number of these excess facilities are massive and robust concrete structures that are suitable for isolating the contained contamination for hundreds of years, and a permanent decommissioning end state option for these facilities is in situ decommissioning (ISD). The ISD option is feasible for a limited, but meaningfull number of DOE contaminated facilities for which there is substantial incremental environmental, safety, and cost benefits versus alternate actions to demolish and excavate the entire facility and transport the rubble to a radioactive waste landfill. A general description of an ISD project encompasses an entombed facility; in some cases limited to the blow-grade portion of a facility. However, monitoring of the ISD structures is needed to demonstrate that the building retains its structural integrity and the contaminants remain entombed within the grout stabilization matrix. The DOE EM Office of Deactivation and Decommissioning and Facility Engineering (EM-13) Program Goal is to develop a monitoring system to demonstrate long-term performance of closed nuclear facilities using the ISD approach. The Savannah River National Laboratory (SRNL) has designed and implemented the In Situ Decommissioning Sensor Network, Meso-Scale Test Bed (ISDSN-MSTB) to address the feasibility of deploying a long-term monitoring system into an ISD closed nuclear facility. The ISDSN-MSTB goal is to demonstrate the feasibility of installing and operating a remote sensor network to assess cementitious material durability, moisture-fluid flow through the cementitious material, and resulting transport potential for contaminate mobility in a decommissioned closed nuclear facility. The original ISDSN-MSTB installation and remote sensor network operation was demonstrated in FY 2011-12 at the ISDSN-MSTB test cube located at the Florida International University Applied Research Center, Miami, FL (FIU-ARC). A follow-on fluid injection test was devel