Powered by Deep Web Technologies
Note: This page contains sample records for the topic "include hotels motels" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Buildings Energy Data Book: 3.10 Hotels/Motels  

Buildings Energy Data Book (EERE)

1 2003 Floorspace and Energy Consumption for Hotels and MotelsInns (1) Hotels MotelsInns Average Electricity Consumption(kBtusSF): 61.3 40.5 Average Natural Gas...

2

ENERGY STAR Building Upgrade Manual Chapter 12: Hotels and Motels...  

NLE Websites -- All DOE Office Websites (Extended Search)

care resources Small business resources State and local government resources ENERGY STAR Building Upgrade Manual Chapter 12: Hotels and Motels The Building Upgrade Manual is...

3

Hotel/motel energy use strategies  

SciTech Connect

A monitoring program for Hotel/Motel energy use in three areas-space heating, space cooling, and domestic hot water systems is reported on. In space heating, thermostats were poorly maintained, base loads were unacceptably high. Waste in space cooling could be reduced by use of economizer systems such as the strainer cycle, indoor-outdoor control, and flywheel storage. Recirculating loops, which provide instantaneous hot water to rooms, might be turned off during non-peak hours. Incoming city main well temperatures can be used to preheat water. The survey found little concern for energy conservation in the commercial areas of hotels. For example, at 2 a.m. all the lights were on in an empty ballroom. Many kitchen appliances were left running. In kitchens the heat booster in dishwashers is left on when the machine is off. The habit of turning on all appliances when the kitchen opens is wasteful. Several other examples are given. Management of hotels must be shown, then, that they are sitting on top of a prime cost center of potential savings.

Smith, A.M.

1982-06-01T23:59:59.000Z

4

Summary report of energy usage/consumption analysis for six hotels/motels  

SciTech Connect

An analysis of energy consumption and energy use profiles for six hotels and motels of various types (transient, convention, resort) located in different geographical areas of the United States is summarized. Data include information collected at the six demonstration sites only during the heating and cooling seasons. Data show where the energy is used, how much is used and when it is used. A brief examination of strategies for reducing energy consumption is also included. Major hotel/motel functions are identified as: guest rooms, public areas, kitchens, dining areas, laundries, pools, elevators, and others. Energy use categories examined are: space heating, space cooling, domestic water heating, cooking, laundry dryers, lighting, HVAC auxiliaries, elevators, and others. The six hotels/motels are located in Vermont, Minnesota, Arizona, Georgia, and two in Texas. The building configuration, facilities, energy-using systems, and climatic conditions are described for each site. (LEW)

1981-12-01T23:59:59.000Z

5

STATE OF CALIFORNIA HOTEL / MOTEL TRANSIENT OCCUPANCY TAX WAIVER  

E-Print Network (OSTI)

FOR STATE AGENCIES) HOTEL MOTEL OPERATORS: RETAIN THIS WAIVER FOR YOUR FILES TO SUBSTANTIATE YOUR REPORTS of the State Agency indicated below; that the charge for the occupancy at the above establishment on the dates of California. $ OCCUPANCY DATES AMOUNT PAID California State University, Fullerton STATE AGENCY NAME 800 North

de Lijser, Peter

6

Experience on design and operation of hotel/motel solar hot water systems  

SciTech Connect

The use of solar energy to preheat domestic hot water in hotels and motels has many advantages. Year long use of these solar systems provides shorter payback periods. Temperature requirements for hotel/motel use are relatively low and are compatible with low cost flat plate collectors. Simple controls relate to higher reliability in both drain-down and heat exchanger configurations. Solar systems are easily retrofitted to most existing hotel/motel hot water systems and there are many hotels and motels across the country with roof area sufficient in size to hold the required collector arrays. Hotel/motel systems with payback periods of less than four years, which provide 70% of the total hot water load, are discussed.

Brohl, E.C.; Struss, R.G.; Sidles, P.H.

1978-01-01T23:59:59.000Z

7

Home Hotel and Motel Pool & Spa Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Home Hotel and Motel Pool & Spa Low Temperature Geothermal Facility Home Hotel and Motel Pool & Spa Low Temperature Geothermal Facility Jump to: navigation, search Name Home Hotel and Motel Pool & Spa Low Temperature Geothermal Facility Facility Home Hotel and Motel Sector Geothermal energy Type Pool and Spa Location Lava Hot Springs, Idaho Coordinates 42.6193625°, -112.0110712° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

8

Energy Star Building Upgrade Manual Facility Type: Hotels and Motels Chapter 12  

NLE Websites -- All DOE Office Websites (Extended Search)

2. Facility Type: 2. Facility Type: Hotels and Motels Revised December 2007 12.1 Challenges and Opportunities 2 12.2 Energy-Use Profile 3 12.3 Technical Recommendations 4 Retrocommissioning 5 Lighting 8 Load Reduction 11 Air Distribution Systems 13 Heating and Cooling Systems 15 12.4 Financial and Implementation Issues 16 Bibliography 17 Glossary G-1 ENERGY STAR ® Building Manual 2 12. Facility Type: Hotels and Motels 12.1 Challenges and Opportunities The United States' 47,000 hotels and motels spend an average of $2,196 per available room each year on energy, an amount that represents about 6 percent of all hotel operating costs. The varied nature of the physical facilities and the activities that they host can make energy management especially challenging, whether the facility is a large convention hotel, part of

9

Texas energy conservation program: existing commercial, hotels and motels. [Workshop material  

SciTech Connect

This publication describes some simple methods by which the owner, manager, or operator of a hotel or motel can analyze its energy uses, determine the areas in which energy savings can be made, and estimate the magnitude of the cost savings in accordance with federal Department of Energy Procedures. The workbook is designed to provide a do-it-yourself fill-in-the-blanks approach to an energy-conservation program and is intended for use in small to medium hotels and motels which do not have full-time engineering personnel. The main energy-intensive functions of a hotel and some of the frequently observed areas of energy waste are emphasized, but it is recognized that each building will have its unique energy-use patterns that must be learned by the owner, manager, or operator or their designated energy coordinator and an energy-management committee. Specific measures are provided for restaurants and coffee shops. A pamphlet on Duo-Aire, the self-contained supply and exhaust air cooking ventilation system, is included.

1978-01-01T23:59:59.000Z

10

ENERGY STAR Building Upgrade Manual Chapter 12: Hotels and Motels | ENERGY  

NLE Websites -- All DOE Office Websites (Extended Search)

12: Hotels and Motels 12: Hotels and Motels Secondary menu About us Press room Contact Us Portfolio Manager Login Facility owners and managers Existing buildings Commercial new construction Industrial energy management Small business Service providers Service and product providers Verify applications for ENERGY STAR certification Design commercial buildings Energy efficiency program administrators Commercial and industrial program sponsors Associations State and local governments Federal agencies Tools and resources Training In This Section Campaigns Commercial building design Communications resources Energy management guidance Financial resources Portfolio Manager Products and purchasing Recognition Research and reports Service and product provider (SPP) resources Success stories Target Finder Technical documentation

11

Glossary G-1 ENERGY STAR Building Manual 1 12. Facility Type: Hotels and Motels  

E-Print Network (OSTI)

The United States 47,000 hotels and motels spend an average of $2,196 per available room each year on energy, an amount that represents about 6 percent of all hotel operating costs. The varied nature of the physical facilities and the activities that they host can make energy management especially challenging, whether the facility is a large convention hotel, part of a large national chain, or a small inn or motel. However, the opportunities for improved guest comfort, longer equipment life, lower operating costs, and an improved corporate image make pursing energy efficiency worthwhile. ENERGY STAR partners in the lodging industry have greatly reduced their expenditures on energy through measures such as lighting upgrades in guest rooms, lobbies, and hallways; occupancy-based guest-room energy controls; and the installation of energy-efficient water heating equipment, while still providing benefits for hotel guests, owners, operators, and shareholders. Hotels and motels operate 24 hours a day, hosting guests and offering various services and amenities. Guest rooms, public lobbies, banquet facilities and restaurants, lounges, offices, retail outlets, and swimming pools fill the building or multiple buildings. Ice machines, vending machines, and game rooms may be scattered throughout. Laundries and kitchens are typically

unknown authors

2007-01-01T23:59:59.000Z

12

Buildings Energy Data Book: 3.10 Hotels/Motels  

Buildings Energy Data Book (EERE)

2 2 Lodging Industy, Sales and Occupancy Rates Year Sales ($2010 billion) Avg. Occupancy Rate Avg. Room Rate ($2010) 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 Note(s): Source(s): 1) Based on properties with 15 or more rooms The American Hotel & Lodging Association, 2002 Lodging Industy Profile, p. 2-3; The American Hotel & Lodging Association, 2003 Lodging Industy Profile, p. 2-3, 2002; The American Hotel & Lodging Association, 2004 Lodging Industy Profile, p. 2-4, 2004; The American Hotel & Lodging Association, 2005 Lodging Industy Profile, p. 2-4, 2005; The American Hotel & Lodging Association, 2006 Lodging Industy Profile, p. 2-4, 2006; The American Hotel & Lodging Association, 2007 Lodging Industy Profile, p. 2-4, 2007; The American Hotel & Lodging Association, 2008 Lodging Industry Profile p. 2-4, 2008; The American

13

Buildings Energy Data Book: 3.10 Hotels/Motels  

Buildings Energy Data Book (EERE)

5 5 Energy Benchmarks for Newly Constructed Large Hotels, by Selected City and End-Use (thousand Btu per square foot) Miami 1A Houston 2A Phoenix 2B Atlanta 3A Los Angeles 3B Las Vegas 3B San Francisco 3C Baltimore 4A Albuquerque 4B Seattle 4C Chicago 5A Boulder 5B Minneapolis 6A Helena 6B Duluth 7 Fairbanks 8 Note(s): Source(s): 60.9 13.2 76.3 8.4 Commercial building energy benchmarks are based off of the current stock of commercial buildings and reflect 2004 ASHRAE 90.1 Climate Zones. They are designed to provide a consistent baseline to compare building performance in energy-use simulations.The benchmark building had 122,075 square feet and 6 floors. Benchmark interior lighting energy = 11.28 thousand Btu/SF. Interior equipment energy consumption = 24.77 thousand Btu/SF. DOE/EERE/BT, Commercial Building Benchmark Models, Version 1.3_5.0, Nov. 2010, accessed January 2012 at

14

Buildings Energy Data Book: 3.10 Hotels/Motels  

Buildings Energy Data Book (EERE)

6 6 Energy Benchmarks for Newly Constructed Small Hotels, by Selected City and End-Use (thousand Btu per square foot) Miami 1A Houston 2A Phoenix 2B Atlanta 3A Los Angeles 3B Las Vegas 3B San Francisco 3C Baltimore 4A Albuquerque 4B Seattle 4C Chicago 5A Boulder 5B Minneapolis 6A Helena 6B Duluth 7 Fairbanks 8 Note(s): Source(s): 36.6 2.7 12.0 3.9 Commercial building energy benchmarks are based off of the current stock of commercial buildings and reflect 2004 ASHRAE 90.1 Climate Zones. They are designed to provide a consistent baseline to compare building performance in energy-use simulations.The benchmark building had 43,186 square feet and 4 floors. Benchmark interior lighting energy = 13.79 thousand Btu/SF. Interior equipment energy consumption = 21.98 thousand Btu/SF. DOE/EERE/BT, Commercial Building Benchmark Models, Version 1.3_5.0, Nov. 2010, accessed January 2012 at

15

Evaluation of economics of hotel/motel solar hot water projects  

SciTech Connect

Experience gained by the Ames Laboratory in managing projects in the Solar Hotel/Motel Hot Water initiative is used to evaluate economic factors. The analysis studies costs and trends from a limited number of projects. Initial analysis, based on cost data presented in the project proposals, shows that cost estimates vary widely for various reasons. Further analysis, based on incurred costs as projects are completed, is a continuing process. These actual costs are normalized to the extent possible to provide consistent comparisons between the systems of various projects. Correlations between proposed costs and actual costs are made to assist future evaluation of similar projects. Several projects, which were offered a grant to participate in these Hotel/Motel demonstrations, have declined to accept the grant on economic grounds. Economic analysis of these projects provides rationale for the apparent cost ineffectiveness. Systems now in operation have provided fuel cost savings data which are presented to show system payback periods. Finally, results of economic analysis of these projects are presented together with initial conclusions regarding cost-effective solar hot water system design.

Struss, R.G.; Brohl, E.C.; Sidles, P.H.

1978-01-01T23:59:59.000Z

16

HOTELS  

NLE Websites -- All DOE Office Websites (Extended Search)

U U Ur rb ba an n A At tm mo os sp ph he er ri ic c O Ob bs se er rv va at to or ry y ( ( U UA AO O) ) F F i ir rs st t P Pl la an nn ni in ng g W Wo or rk ks sh ho op p A Ag ge en nd da a 27-28 January, 2003 HOTELS Please Note: This list is not all-inclusive, but compiled to provide some suggestions. Occupancy at the Government rate is based on availability. The rates vary depending on the time of year, day of the week, number of nights. There are also special rates and packages available at different times of the year. Some hotels offer weekend rates. For an extended list click on this link and search NY: http://www.hotels.com EML is located on the West Side of Manhattan - "lower Manhattan" - Greenwich Village/SoHo area. The following hotels are on the West Side of Manhattan. EML can be reached by subway or taxi. Hotels

17

Local Hotels/Motels - Gaithersburg, MD  

Science Conference Proceedings (OSTI)

... relationship with NIST. We provide this information as a convenience to NIST visitors and conference attendees. NIST does ...

2013-07-25T23:59:59.000Z

18

Buildings Energy Data Book: 3.10 Hotels/Motels  

Buildings Energy Data Book (EERE)

3 3 Lodging Industry Profile (Thousands) 2004 2006 2008 2010 Location Properties Rooms Properties Rooms Properties Rooms Properties Rooms Suburban Highway Urban Airport Resort Small Metro Rate Under $30 $30-44.99 $45-59.99 $60-85 Over $85 Number of Rooms Under 75 75 - 149 150 - 299 300 - 500 Over 500 Source(s): 17.5 1,746 6.7 446 6.8 452 7.1 480 7.3 498 15.8 1,564 15.9 1,577 16.8 1,668 4.9 754 1.9 274 2.0 275 2.1 294 2.2 305 4.6 706 4.5 691 4.7 721 3.8 595 14.5 826 14.4 827 15.1 878 15.4 904 4.1 595 3.6 567 3.7 584 0.8 54 8.0 510 7.1 435 7.3 418 6.6 406 0.9 56 0.9 58 1.2 54 14.5 896 14.3 1,368 14.2 1295 14.5 1326 15.8 1386 16.1 1,045 14.8 933 15.0 916 13.4 2060 27.5 1,164 26.9 1147 27.8 1188 28.1 1212 8.3 1,434 10.1 1668 11.4 1913 16.9 1773 4.2 847 4.1 824 4.3 853 4.4 876 14.3 1,524 14.5 1542 15.8 1668 The American Lodging Association, 2007 Lodging Industy Profile, p. 2-4, 2007; The American Lodging Association, 2008 Lodging Industry Profile p. 2-4,

19

Twin Peaks Motel Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Peaks Motel Space Heating Low Temperature Geothermal Facility Peaks Motel Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Twin Peaks Motel Space Heating Low Temperature Geothermal Facility Facility Twin Peaks Motel Sector Geothermal energy Type Space Heating Location Ouray, Colorado Coordinates 38.0227716°, -107.6714487° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

20

Shoshone Motel & Trailer Park Space Heating Low Temperature Geothermal  

Open Energy Info (EERE)

Shoshone Motel & Trailer Park Space Heating Low Temperature Geothermal Shoshone Motel & Trailer Park Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Shoshone Motel & Trailer Park Space Heating Low Temperature Geothermal Facility Facility Shoshone Motel & Trailer Park Sector Geothermal energy Type Space Heating Location Death Valley, California Coordinates Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

Note: This page contains sample records for the topic "include hotels motels" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Wiesbaden Motel & Health Resort Space Heating Low Temperature Geothermal  

Open Energy Info (EERE)

Wiesbaden Motel & Health Resort Space Heating Low Temperature Geothermal Wiesbaden Motel & Health Resort Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Wiesbaden Motel & Health Resort Space Heating Low Temperature Geothermal Facility Facility Wiesbaden Motel & Health Resort Sector Geothermal energy Type Space Heating Location Ouray, Colorado Coordinates 38.0227716°, -107.6714487° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

22

Box Canyon Motel Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Motel Space Heating Low Temperature Geothermal Facility Motel Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Box Canyon Motel Space Heating Low Temperature Geothermal Facility Facility Box Canyon Motel Sector Geothermal energy Type Space Heating Location Ouray, Colorado Coordinates 38.0227716°, -107.6714487° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

23

Berkeley Hotels  

NLE Websites -- All DOE Office Websites (Extended Search)

Conference Hotel Block Room Reservation Information Conference Hotel Block Room Reservation Information If you plan to attend the SNAP Collaboration Meeting (June 1-3, 2006) and require lodging, please make your hotel reservations as soon as possible. We have block room reservations at these two hotels: 1) Doubletree Berkeley Marina Hotel (block of rooms reserved until May 10, 2006) 2) Hotel Durant (block of rooms reserved until May 1, 2006) Doubletree Berkeley Marina (three star hotel). Government Rates are: $100 (Single), $100 (Double), $110 (Triple), $120(Quad). Block room reservation for 30 rooms are for May 31 through June 3 (check-out), and is valid through Wednesday, May 10, 2006. To make a reservation: Please call the hotel (510-548-7920) by May 10th to make your reservations. To obtain the government rate, please let them know that you are with the "SNAP" group or the three letter code, "SNA". You will then need to give them your credit card information to make the reservation.

24

Enegiutredning Hotell Princess.  

E-Print Network (OSTI)

?? This report will show the energy usage of Hotel Princess in Sandviken, Sweden. When the hotel changed owner an examination of the hotels heating, (more)

Ros, Henrik

2012-01-01T23:59:59.000Z

25

Occupancy sensors for HVAC gaining in hotel industry  

SciTech Connect

The hotel industry is overcoming its skepticism as occupancy sensors with built-in thermistors to control heating, ventilating, and air conditioning (HVAC) units demonstrate their ability to cut energy costs as much as 30%. Despite the successful demonstrations and acceptance by Holiday Inn, some hotel managers of other chains continue to resist. Occupancy sensors have either ultrasonic or infrared signals, but differ from lighting control devices by also having internal thermistors and remote door switches. This allows the rooms to reach comfort levels only when the guest is present since occupants are only minimally affected if temperatures are modified during unoccupied periods. The system works best for roadside-type motels rather than convention hotels, where occupants are in and out of their rooms.

Ladd, C.

1985-12-02T23:59:59.000Z

26

hotels.PDF  

NLE Websites -- All DOE Office Websites (Extended Search)

Some Berkeley Hotels 1 4 2 3 5 1. Hotel Shattuck Plaza, 2086 Allston Way 510845-7300 2. Hotel Durant, 2600 Durant Ave. 510845-8981 3. Bancroft Club Hotel, 2680 Bancroft Way 510...

27

Cogeneration for resort hotels  

Science Conference Proceedings (OSTI)

Resort Hotels should be considered for application of co-generation to take advantage of higher thermal efficiency and consequent energy cost avoidance. Modern resort hotels require comfort and reliability from mechanical and electrical systems on an around the clock basis. Load profiling reveals simultaneous process heating and electricity use requirements that aid in the selection and sizing of co-generation equipment. Resort Hotel needs include electrical loads for lighting, fan motors, elevators, escalators and receptacle uses. Process heat demands arise from kitchen, servery, banquet, restaurant, laundry, and bakery functions. Once the loads requiring service have been quantified and realigned (shifted) to maximize simultaneous demands the engineering task of co-generation application becomes one of economics. National legislation is now in place to foster the use of co-generating central utility plants. Serving utility companies are now by law required to buy back excess energy during periods of reduced hotel demands. Resort Hotel loads, converted into electricity and heat demands are tabulated in terms of savings (positive cash flow) or costs (negative cash flows). Cash flow tabulations expressed in graphs are included. The graphs show the approximate simple payback on initial costs of co-generation systems based on varying electricity charges.

Baker, T.D.

1986-01-01T23:59:59.000Z

28

SRI2013 | Hotel Accommodations  

Science Conference Proceedings (OSTI)

... blocks of rooms in two local hotels: ... DC North/Gaithersburg hotel (apparently booked up). ... Cornell High Energy Synchrotron Source; Canadian Light ...

29

Charles Motel & Bathhouse Pool & Spa Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Motel & Bathhouse Pool & Spa Low Temperature Geothermal Facility Motel & Bathhouse Pool & Spa Low Temperature Geothermal Facility Jump to: navigation, search Name Charles Motel & Bathhouse Pool & Spa Low Temperature Geothermal Facility Facility Charles Motel & Bathhouse Sector Geothermal energy Type Pool and Spa Location Truth or Consequences, New Mexico Coordinates 33.1284047°, -107.2528069° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

30

Spa Motel Pool & Spa Low Temperature Geothermal Facility | Open Energy  

Open Energy Info (EERE)

Spa Motel Pool & Spa Low Temperature Geothermal Facility Spa Motel Pool & Spa Low Temperature Geothermal Facility Jump to: navigation, search Name Spa Motel Pool & Spa Low Temperature Geothermal Facility Facility Spa Motel Sector Geothermal energy Type Pool and Spa Location White Sulphur Springs, Montana Coordinates 46.548277°, -110.9021561° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

31

Caliente Hot Springs Motel Pool & Spa Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Motel Pool & Spa Low Temperature Geothermal Facility Motel Pool & Spa Low Temperature Geothermal Facility Jump to: navigation, search Name Caliente Hot Springs Motel Pool & Spa Low Temperature Geothermal Facility Facility Caliente Hot Springs Motel Sector Geothermal energy Type Pool and Spa Location Caliente, Nevada Coordinates 37.6149648°, -114.5119378° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

32

ENERGY STAR Score for Hotels  

NLE Websites -- All DOE Office Websites (Extended Search)

Hotels in the United States Page 1 ENERGY STAR Score for Hotels in the United States Technical Reference OVERVIEW The ENERGY STAR Score for Hotels applies to properties renting...

33

Airport, Transport & Hotel Information | ORNL  

NLE Websites -- All DOE Office Websites (Extended Search)

Departures - Live departure schedule Airlines - Links to individual airlines' websites Car Rental Flight Schedules Hotels - Area hotels Parking - Rates and suggestions Taxi -...

34

In order to take advantage of these rates, please book directly with the hotel via email, phone or fax  

E-Print Network (OSTI)

VENUE 2 STAR HOTELS Hotel Balbi ** Via Balbi 21/3 ­ tel +39 010 2759288 ­ fax +39 010 252362 website www quadruple room 105 breakfast included Hotel della Posta ** Via Balbi 24 ­ tel +39 010 252929 ­ fax +39 010 from 70 triple room from 85 breakfast included Hotel Acquaverde ** Via Balbi 29 ­ tel +39 010 265427

Genova, Università degli Studi di

35

Oak Ridge Hotels | ornl.gov  

NLE Websites -- All DOE Office Websites (Extended Search)

Conferences Highlights Success Stories Contact Us Index Home | ORNL | Visiting ORNL SHARE Oak Ridge Hotels Contact information for local hotels is listed below. At ORNL Hotel...

36

Solid-State Lighting: Hotel Information  

NLE Websites -- All DOE Office Websites (Extended Search)

Hotel Information on Twitter Bookmark Solid-State Lighting: Hotel Information on Google Bookmark Solid-State Lighting: Hotel Information on Delicious Rank Solid-State...

37

IntegratedEnergySysteminHotel (GasTechnologyInstitute)  

E-Print Network (OSTI)

A experimental area, using beams from the present GSI accelerator complex (energy range: 500 to 10 Me a contingent of rooms is available at the IBIS hotel in Darmstadt. The room rate is 71.00 per person and night, breakfast included. This arrangement will be valid latest until October 19. Please contact the hotel

Oak Ridge National Laboratory

38

Sheraton Seattle Hotel Floor Plans  

Science Conference Proceedings (OSTI)

139th Annual Meeting & Exhibition. Sheraton Seattle Hotel Floor Plans. MEETING ROOMS. RESTROOMS. LEVEL 1. LEVEL. MEETING INFORMATION.

39

Executive Summary The Morgantown metropolitan statistical area (MSA) continues to be a force for growth in West  

E-Print Network (OSTI)

year growth. Leisure and hospitality includes motels/hotels, bars and restaurants, as well as local at a slower pace, as investments in hotels/motels in the region generate future job gains. Finally Corporation www.bber.wvu.edu This conference is made possible by the following underwriters: Chesapeake Energy

Mohaghegh, Shahab

40

Category:SmallHotel | Open Energy Information  

Open Energy Info (EERE)

SmallHotel SmallHotel Jump to: navigation, search Go Back to PV Economics By Building Type Media in category "SmallHotel" The following 77 files are in this category, out of 77 total. SVSmallHotel Bismarck ND Montana-Dakota Utilities Co (North Dakota).png SVSmallHotel Bismarck ... 71 KB SVSmallHotel International Falls MN Northern States Power Co (Minnesota) Excel Energy.png SVSmallHotel Internati... 83 KB SVSmallHotel LA CA City of Los Angeles California (Utility Company).png SVSmallHotel LA CA Cit... 87 KB SVSmallHotel Memphis TN City of Memphis Tennessee (Utility Company).png SVSmallHotel Memphis T... 65 KB SVSmallHotel Minneapolis MN Northern States Power Co (Minnesota) Excel Energy.png SVSmallHotel Minneapol... 83 KB SVSmallHotel Minot ND Montana-Dakota Utilities Co (North Dakota).png

Note: This page contains sample records for the topic "include hotels motels" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Category:LargeHotel | Open Energy Information  

Open Energy Info (EERE)

LargeHotel LargeHotel Jump to: navigation, search Go Back to PV Economics By Building Type Media in category "LargeHotel" The following 77 files are in this category, out of 77 total. SVLargeHotel Bismarck ND Montana-Dakota Utilities Co (North Dakota).png SVLargeHotel Bismarck ... 70 KB SVLargeHotel International Falls MN Northern States Power Co (Minnesota) Excel Energy.png SVLargeHotel Internati... 85 KB SVLargeHotel LA CA City of Los Angeles California (Utility Company).png SVLargeHotel LA CA Cit... 88 KB SVLargeHotel Memphis TN City of Memphis Tennessee (Utility Company).png SVLargeHotel Memphis T... 67 KB SVLargeHotel Minneapolis MN Northern States Power Co (Minnesota) Excel Energy.png SVLargeHotel Minneapol... 85 KB SVLargeHotel Minot ND Montana-Dakota Utilities Co (North Dakota).png

42

Preplanning gives savings in new hotel construction  

SciTech Connect

A new trend toward preplanning energy conservation in new hotel design is lowering energy costs for new construction 25 to 50%. The architectural/engineering preplanning options that can accomplish an energy goal and be integrated into the architectural/engineering process include how the building is oriented, how much and what kind of glass it contains, what energy-management systems will be installed, and whether to include cogeneration with waste-heat recovery systems. (DCK)

Watson, F.

1983-11-07T23:59:59.000Z

43

Solid-State Lighting: Hotel Information  

NLE Websites -- All DOE Office Websites (Extended Search)

Hotel Information to someone by Hotel Information to someone by E-mail Share Solid-State Lighting: Hotel Information on Facebook Tweet about Solid-State Lighting: Hotel Information on Twitter Bookmark Solid-State Lighting: Hotel Information on Google Bookmark Solid-State Lighting: Hotel Information on Delicious Rank Solid-State Lighting: Hotel Information on Digg Find More places to share Solid-State Lighting: Hotel Information on AddThis.com... Conferences & Meetings Past Conferences Presentations Publications Webcasts Videos Tools Hotel Information Hilton Tampa Downtown 211 N. Tampa St. Tampa, FL 33602 A block of hotel rooms has been reserved at the Hilton Tampa at a special rate for DOE workshop attendees. The rate for a standard room is $116 per night from January 25-February 1. The room block has been extended until noon ET on Friday, January 17,

44

REDUCTIONS WITHOUT REGRET: AVOIDING WRONG TURNS, ROACH MOTELS, AND BOX CANYONS  

SciTech Connect

This is the third of three papers (in addition to an introductory summary) aimed at providing a framework for evaluating future reductions or modifications of the U.S. nuclear force, first by considering previous instances in which nuclear-force capabilities were eliminated; second by looking forward into at least the foreseeable future at the features of global and regional deterrence (recognizing that new weapon systems currently projected will have expected lifetimes stretching beyond our ability to predict the future); and third by providing examples of past or possible undesirable outcomes in the shaping of the future nuclear force, as well as some closing thoughts for the future. In this paper, we provide one example each of our judgments on what constitutes a box canyon, a roach motel, and a wrong turn: ? Wrong Turn: The Reliable Replacement Warhead ? Roach Motel: SRAM T vs the B61 ? A Possible Box Canyon: A Low-Yield Version of the W76 SLBM Warhead Recognizing that new nuclear missions or weapons are not demanded by current circumstances ? a development path that yields future capabilities similar to those of today, which are adequate if not always ideal, and a broader national-security strategy that supports nonproliferation and arms control by reducing the role for, and numbers, of nuclear weapons ? we briefly consider alternate, less desirable futures, and their possible effect on the complex problem of regional deterrence. In this regard, we discuss the issues posed by, and possible responses to, three example regional deterrence challenges: in-country defensive use of nuclear weapons by an adversary; reassurance of U.S. allies with limited strategic depth threatened by an emergent nuclear power; and extraterritorial, non-strategic offensive use of nuclear weapons by an adversary in support of limited military objectives against a U.S. ally.

Swegle, J.; Tincher, D.

2013-09-11T23:59:59.000Z

45

ENERGY STAR Success Story: HEI Hotels & Resorts | ENERGY STAR  

NLE Websites -- All DOE Office Websites (Extended Search)

Story: HEI Hotels & Resorts HEI Hotels & Resorts is a growing hospitality company with 30 hotel properties in 13 states. Since launching its partnership with ENERGY STAR in 2006,...

46

Quark Matter 2004 Conference Hotel  

NLE Websites -- All DOE Office Websites (Extended Search)

as the conference Hotel. It is adjacent to the Oakland Convention Center where all Quark Matter talks will be held. Quark Matter attendees can get a reduced price of 126...

47

West Virginia Higher Education Graduate  

E-Print Network (OSTI)

the importance of the energy sector to the state. The coal and natural gas sectors continued to post strong includes hotels, motels, restaurants, and bars. It also includes the gaming sector. #12;W.Va. Graduate

Mohaghegh, Shahab

48

Solid-State Lighting: Hotel Information  

NLE Websites -- All DOE Office Websites (Extended Search)

Program » Solid-State Lighting » Program » Solid-State Lighting » Information Resources Printable Version Share this resource Send a link to Solid-State Lighting: Hotel Information to someone by E-mail Share Solid-State Lighting: Hotel Information on Facebook Tweet about Solid-State Lighting: Hotel Information on Twitter Bookmark Solid-State Lighting: Hotel Information on Google Bookmark Solid-State Lighting: Hotel Information on Delicious Rank Solid-State Lighting: Hotel Information on Digg Find More places to share Solid-State Lighting: Hotel Information on AddThis.com... Home Conferences & Meetings Past Conferences Presentations Publications Webcasts Videos Hotel Information Wyndham Grand Pittsburgh, 600 Commonwealth Place, Pittsburgh, PA 15222 The Wyndham Grand Pittsburgh room block has expired; however,

49

Sheraton Seattle Hotel Floor Plans - TMS  

Science Conference Proceedings (OSTI)

LEARN NETWORK ADVANCE. Sheraton Seattle Hotel Floor Plans. MEETING ROOMS. RESTROOMS. LEVEL. PIKE ST. TOWER. UNION ST. TOWER.

50

Forecasting Uncertain Hotel Room Demand  

E-Print Network (OSTI)

Economic systems are characterized by increasing uncertainty in their dynamics. This increasing uncertainty is likely to incur bad decisions that can be costly in financial terms. This makes forecasting of uncertain economic variables an instrumental activity in any organization. This paper takes the hotel industry as a practical application of forecasting using the Holt-Winters method. The problem here is to forecast the uncertain demand for rooms at a hotel for each arrival day. Forecasting is part of hotel revenue management system whose objective is to maximize the revenue by making decisions regarding when to make rooms available for customers and at what price. The forecast approach discussed in this paper is based on quantitative models and does not incorporate management expertise. Even though, forecast results are found to be satisfactory for certain days, this is not the case for other arrival days. It is believed that human judgment is important when dealing with ...

Mihir Rajopadhye Mounir; Mounir Ben Ghaliay; Paul P. Wang; Timothy Baker; Craig V. Eister

2001-01-01T23:59:59.000Z

51

Development of an Enterprise-wide Energy Information and Utility Monitoring System in a Major Hotel Chain: The Hyatt Hotels Corporation Experience  

E-Print Network (OSTI)

Hyatt Hotels Corporation is currently implementing an enterprise-wide Energy Information and Utility Monitoring System (UMS). New Horizon Technologies and eComponents Technology have teamed to provide an integrated solution that will ultimately include all Hyatt Hotels in North America. In addition, these 120 Hyatt Hotels participate in a monthly web-based energy benchmarking and hotel engineering reporting system. For hotels with Utility Monitoring Systems (UMS) installed, energy and water consumption data is automatically summarized for the web reports. Hotels without the UMS enter monthly utility data manually on the website. The base UMS at the hotels consists of electric, gas and domestic water consumption and local temperature and relative humidity measurements. The Hyatt UMS is one of the first enterprise-wide systems to include domestic water metering. Many hotels elect to install additional sub-metering for major loads or end uses such as chillers, kitchens and laundries. The local hotel UMS consists of a data acquisition system capable of displaying real-time data that also logs 15-minute interval data. The system transfers interval data daily, to a data center and also transfers interval data hourly, via a Local Area Network, to an on-site workstation with a local database. The local workstation permits users to have real-time alarming capability, access to easy-touse data visualization and analysis tools, and the ability to generate both customized and standard daily and monthly reports. Report writing and utility costing software are used to generate daily and month-to-date cost reports. Bill estimation software uses actual utility rate tariff models to create estimates of utility costs for any custom defined period. Data resident in the Hyatt data center is accessible to the individual hotels using a web-based system. Senior engineers with authorization can access data for all Hyatt Hotels in their regions. The corporate energy director and senior management have access to all data in the Hyatt data center. Browser-based hotel benchmarking data is also available through a similar system with an authorization hierarchy. This paper will describe the design and implementation of the Hyatt UMS in detail, review how the system is currently being used by Hyatt personnel, discuss potential future applications and provide an initial look at UMS system-wide data, including a preliminary return on investment (ROI) analysis.

Burke, B.; McBride, J.; Kimble, K.

2003-01-01T23:59:59.000Z

52

Hotels & Accommodations - Clean Cities Transportation Workshop...  

NLE Websites -- All DOE Office Websites (Extended Search)

Hotels & Accommodations Workshops Clean Cities Transportation Workshop for Almaty KZ Workshop Home First Announcement (EN), PDF 288KB First Announcement (RU), PDF 404KB Trainers &...

53

Hotel Scoring Model FAQs | ENERGY STAR  

NLE Websites -- All DOE Office Websites (Extended Search)

use per square foot, and service levels based on operating characteristics. Download the ENERGY STAR Hotel Rating Model FAQs here. Energy Efficient Products Learn about ENERGY...

54

Hotel energy use contributes to global warming.  

E-Print Network (OSTI)

??Before learning about the consequences of global warming and the efforts hotels are making to reverse the effects, it is important to get a better (more)

Faja, Christine

2007-01-01T23:59:59.000Z

55

Symes Hotel and Medicinal Springs Pool & Spa Low Temperature...  

Open Energy Info (EERE)

Hotel and Medicinal Springs Pool & Spa Low Temperature Geothermal Facility Facility Symes Hotel and Medicinal Springs Sector Geothermal energy Type Pool and Spa Location Hot...

56

Glenwood Hot Springs Hotel Pool & Spa Low Temperature Geothermal...  

Open Energy Info (EERE)

Hotel Pool & Spa Low Temperature Geothermal Facility Facility Glenwood Hot Springs Hotel Sector Geothermal energy Type Pool and Spa Location Glenwood Springs, Colorado...

57

Evaluate hotel energy performance using data envelopment analysis.  

E-Print Network (OSTI)

???There are many factors affecting the hotel energy consumption, such as hotel classifications, floor area, numbers of guest rooms, nos. of room guests, mix of (more)

Wan, Chun-wah.

2012-01-01T23:59:59.000Z

58

Commercial Reference Building: Large Hotel | OpenEI  

Open Energy Info (EERE)

Hotel Hotel Dataset Summary Description Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus simulation software. Included here is data pertaining to the reference building type Large Hotel for each of the 16 climate zones, and each of three construction categories: new construction, post-1980 construction existing buildings, pre-1980 construction existing buildings.The dataset includes four key components: building summary, zone summary, location summary and a picture. Building summary includes details about: form, fabric, and HVAC. Zone summary includes details such as: area, volume, lighting, and occupants for all types of zones in the building. Location summary includes key building information as it pertains to each climate zone, including: fabric and HVAC details, utility costs, energy end use, and peak energy demand.In total, DOE developed 16 reference building types that represent approximately 70% of commercial buildings in the U.S.; for each type, building models are available for each of the three construction categories. The commercial reference buildings (formerly known as commercial building benchmark models) were developed by the U.S. Department of Energy (DOE), in conjunction with three of its national laboratories.Additional data is available directly from DOE's Energy Efficiency & Renewable Energy (EERE) Website, including EnergyPlus software input files (.idf) and results of the EnergyPlus simulations (.html).

59

Eficiencia energtica y energas renovables en los hoteles de Uruguay  

E-Print Network (OSTI)

-Mashaqbah, S., Mashal, K., & Mohsen, M. (2008). Potential of energy savings in the hotel sector in Jordan identifying energy consumption, attitudes, willingness and practices of certain classified hotels. The data classified hotels had installed energy saving tools, and only (2 -5) higher starred hotels managers were

Escolano, Francisco

60

Performance of a hotel chilled water plant with cool storage  

SciTech Connect

A comprehensive monitoring suite was installed at a large convention hotel located in San Francisco, CA. The instrumentation was used for a research project to evaluate the effectiveness of electricity price based controls that automate response to real time pricing and to characterize the operation and performance of the hotel's chilled water plant that included a newly installed ice cool storage system. The hotel operates under real-time electricity rates. To date, over four years of data have been collected. Data included electricity use for all chillers, secondary coolant, chilled water, condenser pumps, and the cooling tower fans. Thermal flow data were also collected for the storage system, ice chiller, direct cooling chillers, and chilled water load loops. This paper (1) describes the chilled water plant, (2) defines the performance measurement objectives for the project, (3) discusses operational experience with the plant, focusing on the cool storage system, (4) analyzes chilled water plant and cool storage system operation by examining the charge/discharge heat flow data, and (5) evaluates how well the plant as a whole and the cool storage system specifically met cooling loads of the facility, and how this affected their use.

Gillespie, K.L.; Blanc, S.L.; Parker, S.

1999-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "include hotels motels" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Spinning reserve from hotel load response  

SciTech Connect

Even though preliminary tests were not conducted during times of highest system or hotel loading during the summer, they showed that hotel load can be curtailed by 22 to 37 percent depending on the outdoor temperature and time of day. Full response occurred in 12 to 60 seconds from when the system operator's command to shed load was issued and the load drop was very rapid. (author)

Kirby, Brendan; Kueck, John; Laughner, Theo; Morris, Keith

2008-12-15T23:59:59.000Z

62

Assessing the applicability of trigeneration in the hotel sector  

Science Conference Proceedings (OSTI)

The objective of the present work is to propose a methodology through which the decision makers can assess the feasibility of promoting trigeneration systems in the hotel industry. The power demand of a representative hotel in N. Cyprus was monitored ... Keywords: absorption chiller, economical analysis, energy, hotels, trigeneration

M. Ozdenefe; U. Atikol

2010-02-01T23:59:59.000Z

63

COLLEGE OF HOTEL ADMINISTRATION SUMMARY: UNLV CAREER OUTCOMES 2008 -2009  

E-Print Network (OSTI)

UTILIZED BY HOTEL ADMINISTRATION STUDENTS #1 UNLV CareerLink (Online Recruiting System) #2 UNLV Career DayCOLLEGE OF HOTEL ADMINISTRATION SUMMARY: UNLV CAREER OUTCOMES 2008 - 2009 Summary of the Career! For College of Hotel Administration graduates, 82% of all respondents indicated they worked while attending

Hemmers, Oliver

64

STATISTICAL MECHANICS CONFERENCE HOTEL INFORMATION The following hotels can be used during the conference and will provide a discounted rate. When making your reservation please mention  

E-Print Network (OSTI)

conference stay at this hotel and will utilize the shuttle service) Convenient to Rutgers University ­ lessSTATISTICAL MECHANICS CONFERENCE HOTEL INFORMATION The following hotels can be used during Hotel front desk: 732-828-8000 | Hotel fax: 732-220-0314 Howard Johnson Express Inn official website

Glashausser, Charles

65

Jebel Ali Hotel PV lighting systems  

SciTech Connect

A large stand-alone PV lighting project was installed in June 1983 at the Jebel Ali Hotel in Dubai, United Arab Emirates. A high mast lighting system provides illumination for a 130 meter diameter traffic roundabout. The high mast system is powered by a 15 kilowatt peak array of Mobil Solar ribbon PV modules. Along the 700 meter access road leading to the hotel entrance, twenty-one PV powered streetlights provide low-level lighting. Each streetlight consists of a 20 watt fluorescent tube powered by two 35 Wp modules. Operation of both systems is completely automatic. Design, installation, and operating experience to date are reviewed.

Ellis, M.

1984-05-01T23:59:59.000Z

66

Index of /2006_SNAPCollab/hotel_files  

NLE Websites -- All DOE Office Websites (Extended Search)

hotel_files hotel_files Icon Name Last modified Size Description [DIR] Parent Directory - [IMG] 1bancroft_hotel.gif 07-Sep-2007 17:56 23K [IMG] FH_logo.jpg 07-Sep-2007 17:56 4.1K [IMG] beau_sky.gif 07-Sep-2007 17:56 12K [IMG] claremont.gif 07-Sep-2007 17:56 20K [IMG] doubletree.jpg 07-Sep-2007 17:56 23K [IMG] holidayinn.gif 07-Sep-2007 17:56 3.6K [IMG] hoteldurant.gif 07-Sep-2007 17:56 8.0K [IMG] radisson.gif 07-Sep-2007 17:56 4.1K [IMG] ramadalogo.gif 07-Sep-2007 17:56 9.4K [IMG] sh_hp_logo.gif 07-Sep-2007 17:56 2.7K [IMG] shattuck_hotel.gif 07-Sep-2007 17:56 5.8K [IMG] travelodge.gif 07-Sep-2007 17:56 8.2K

67

Archive Reference Buildings by Building Type: Large Hotel | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Large Hotel Large Hotel Archive Reference Buildings by Building Type: Large Hotel Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available. You can download ZIP files that contain the following: An EnergyPlus software input file (.idf) An html file showing the results from the EnergyPlus simulation (.html) A spreadsheet that summarizes the inputs and results for each location (.xls) The EnergyPlus TMY2 weather file (.epw). benchmark-v1.0_3.0-large_hotel.zip benchmark-v1.1_3.1-large_hotel.zip benchmark-new-v1.2_4.0-large_hotel.zip More Documents & Publications Archive Reference Buildings by Building Type: Small Hotel

68

Proceedings of the 45th IEEE Conference on Decision & Control Manchester Grand Hyatt Hotel  

E-Print Network (OSTI)

Proceedings of the 45th IEEE Conference on Decision & Control Manchester Grand Hyatt Hotel San can supply. For a DES, commonly applied performance metrics include average system time, utilization and operate the system or the resources that the system utilizes, such as communication channels, space, time

Cassandras, Christos G.

69

SICE Annual Conference 2010 August 18-21, 2010, The Grand Hotel, Taipei, Taiwan  

E-Print Network (OSTI)

SICE Annual Conference 2010 August 18-21, 2010, The Grand Hotel, Taipei, Taiwan ¥400 © 2010 SICE. Thus, the proposed system can potentially be utilized in the legged robots where the COM moves due utilized in various applications, including navigation (robots, vehicles, rockets, and etc) [2-4], state

Lin, Pei-Chun

70

Commercial Reference Building: Small Hotel | OpenEI  

Open Energy Info (EERE)

60 60 Varnish cache server Browse Upload data GDR 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation: XID: 2142278160 Varnish cache server Commercial Reference Building: Small Hotel Dataset Summary Description Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus simulation software. Included here is data pertaining to the reference building type Small Hotel for each of the 16 climate zones, and each of three construction categories: new construction, post-1980 construction existing buildings, pre-1980 construction existing buildings.The dataset includes four key components: building summary, zone summary, location summary and a picture. Building summary includes details about: form, fabric, and HVAC. Zone summary includes details such as: area, volume, lighting, and occupants for all types of zones in the building. Location summary includes key building information as it pertains to each climate zone, including: fabric and HVAC details, utility costs, energy end use, and peak energy demand.In total, DOE developed 16 reference building types that represent approximately 70% of commercial buildings in the U.S.; for each type, building models are available for each of the three construction categories. The commercial reference buildings (formerly known as commercial building benchmark models) were developed by the U.S. Department of Energy (DOE), in conjunction with three of its national laboratories.Additional data is available directly from DOE's Energy Efficiency & Renewable Energy (EERE) Website, including EnergyPlus software input files (.idf) and results of the EnergyPlus simulations (.html).

71

Update to ENERGY STAR Ratings for Hotels, FAQs  

NLE Websites -- All DOE Office Websites (Extended Search)

Update to ENERGY STAR Ratings for Hotels Update to ENERGY STAR Ratings for Hotels May 2009 Frequently Asked Questions EPA's energy performance rating system evaluates actual, as-billed energy data to create a whole building indicator of energy performance and compare a building to its national peer group. EPA analyzes national survey data, develops regression models to predict energy use based on operation, and assigns a 1-to-100 rating to a building. Each point on the performance scale represents one percentile of buildings. A full overview of this process and specific details on the hotel model are available online. 1 A revised rating model for hotels was released into Portfolio Manager on February 23, 2009. How was the Hotel Model Updated? The new hotel model incorporates several updates to the original model, as described below. All of the changes have

72

1999 Baldrige Award Recipient, Ritz-Carlton Hotel Company ...  

Science Conference Proceedings (OSTI)

... Ritz-Carlton President and Chief Operating Officer Horst Schulze began his career in the hospitality industry as a waiter's apprentice at a hotel in ...

2010-10-05T23:59:59.000Z

73

Servidyne Systems and The Ritz Carlton Hotel Company: SPP Success...  

NLE Websites -- All DOE Office Websites (Extended Search)

performance ratings through ENERGY STAR. Download the Servidyne Systems and Ritz Carlton Hotel Company SPP Success Story here. Energy Efficient Products Learn about ENERGY STAR...

74

Greening in the United States hotel sector: An exploratory examination.  

E-Print Network (OSTI)

??The aim of this paper is to explore the concept of greening in the U.S. hotel sector. Much of the existing research on the topic (more)

Kaplan, Adam

2008-01-01T23:59:59.000Z

75

Hotel restaurant concept selection considerations: Which factors to take into account?.  

E-Print Network (OSTI)

??Hotels fulfill a variety of roles in our society. For many travelers and vacationers, a hotel is a home away from home. A wide range (more)

Bakker, Michiel A.

2006-01-01T23:59:59.000Z

76

COLLEGE OF HOTEL ADMINISTRATION SUMMARY: UNLV CAREER OUTCOMES 2007 -2008  

E-Print Network (OSTI)

Outcomes Survey conducted by Career Services after graduation TOP 7 CAREER SERVICES UTILIZED BY HOTELCOLLEGE OF HOTEL ADMINISTRATION SUMMARY: UNLV CAREER OUTCOMES 2007 - 2008 Summary of the Career of Hotel Administration graduates, 84% of respondents indicated they worked while attending school, about

Hemmers, Oliver

77

Forecasting Hotel Arrivals and Occupancy Using Monte Carlo Simulation  

E-Print Network (OSTI)

Forecasting Hotel Arrivals and Occupancy Using Monte Carlo Simulation Athanasius Zakhary Faculty University, Giza, Egypt (n.elgayar@fci-cu.edu.eg) #12;Abstract Forecasting hotel arrivals and occupancy simulation approach for the arrivals and occupancy forecasting problem. In this approach we simulate

Atiya, Amir

78

ENERGY STAR Success Story: HEI Hotels & Resorts, August 2009  

NLE Websites -- All DOE Office Websites (Extended Search)

HEI Hotels & Resorts HEI Hotels & Resorts HEI Hotels & Resorts is a growing hospitality company with 30 hotel properties in 13 states. Since launching its partnership with ENERGY STAR in 2006, HEI has expanded its corporate commitment to become an industry leader in sustainability initiatives, demonstrating that environmentally sound projects can be financially sound projects as well. HEI has earned the ENERGY STAR for two hotel properties, and has been recognized by the Association of Energy Engineers with the 2009 International Corporate Energy Management Award. Energy Management with ENERGY STAR HEI has integrated the ENERGY STAR strategic approach to energy management in all facets of its business - from procurement of ENERGY STAR qualified lighting, HVAC, computer, and commercial

79

90.1 Prototype Building Models Large Hotel | Building Energy Codes Program  

NLE Websites -- All DOE Office Websites (Extended Search)

Hotel Hotel The ASHRAE Standard 90.1 prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. This suite of ASHRAE Standard 90.1 prototype buildings covers all the Reference Building types except supermarket, and also adds a new building prototype representing high-rise apartment buildings.The prototype models include 16 building types in 17 climate locations for ASHRAE Standards 90.1-2004, 90.1-2007 and 90.1-2010. This combination leads to a set of 816 building models (in EnergyPlus Version 6.0). Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the

80

90.1 Prototype Building Models Small Hotel | Building Energy Codes Program  

NLE Websites -- All DOE Office Websites (Extended Search)

Hotel Hotel The ASHRAE Standard 90.1 prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. This suite of ASHRAE Standard 90.1 prototype buildings covers all the Reference Building types except supermarket, and also adds a new building prototype representing high-rise apartment buildings.The prototype models include 16 building types in 17 climate locations for ASHRAE Standards 90.1-2004, 90.1-2007 and 90.1-2010. This combination leads to a set of 816 building models (in EnergyPlus Version 6.0). Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the

Note: This page contains sample records for the topic "include hotels motels" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Regulations establishing energy-conservation standards for new residential buildings  

SciTech Connect

The text of the California Administrative Code, Title 24, Part 6, Article 1 is presented. The energy conservation standards described apply to all new hotels, motels, apartment houses, lodging houses, dwellings, and other residential buildings which are heated or mechanically cooled. Standards for the building envelope, climate control systems and equipment, and water heating are included. (MCW)

Not Available

1980-02-01T23:59:59.000Z

82

Foreign Fishery Developments Marine Angling in Australia  

E-Print Network (OSTI)

with bait, while those using spinning lures number 26 percent; 18 percent utilize pots and/or rings to take in 1983-84 to $2.2 billion (not included in this figure, however, was money spent for hotel/motel etc

83

Peppermill Hotel Casino Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Peppermill Hotel Casino Space Heating Low Temperature Geothermal Facility Peppermill Hotel Casino Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Peppermill Hotel Casino Space Heating Low Temperature Geothermal Facility Facility Peppermill Hotel Casino Sector Geothermal energy Type Space Heating Location Reno, Nevada Coordinates 39.5296329°, -119.8138027° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

84

SunShot Concentrating Solar Power Program Review 2013 - Hotel...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

SunShot Concentrating Solar Power Program Review 2013 April 23-25, 2013 Phoenix, Arizona Skip navigation to main content Menu Home About Agenda Register Venue Presentations Hotel...

85

Spinning Reserve from Hotel Air Conditioning Load - SHORT VERSION  

SciTech Connect

Even though preliminary tests were not conducted during times of highest system or hotel loading during the summer, they showed that hotel load can be curtailed by 22 to 37 percent depending on the outdoor temperature and time of day. Full response occurred in 12 to 60 seconds from when the system operator's command to shed load was issued and the load drop was very rapid.

Kueck, John D [ORNL; Kirby, Brendan J [ORNL

2008-01-01T23:59:59.000Z

86

Hotel in the Bahamas profits from solar hot water system  

SciTech Connect

On Paradise Island, located in the Bahamas, American Energy Technologies Inc. (AET) recently designed and supplied a domestic solar water heating system for the new Comfort Suites Hotel. AET is a Florida manufacturer of solar thermal collectors. The hotel has 150 rooms. Hot water usage entails the laundry facilities and the limited kitchen facilities. Access to hot showers is more of a luxury in some places, but guests at the Comfort Suites Hotel need not be concerned. During the development of the hotel, it was noted that the high heating costs of the propane-fueled hotel boiler were somewhat prohibitive. Propane cost approximately $1.67/gallon, causing the cost of heating water for the hotel to be estimated at over $1,000 per month. To offset the high heating costs, a 49-collector system on a 3200 gallon storage tank was designed into the plans for the new facility. The 49 roof mounted collectors were placed on a direct solar link to the 3200 gallon storage tank. The water is preheated before it gets to the boiler, cutting costs tremendously.

1993-01-01T23:59:59.000Z

87

Fusion Energy Sciences Advisory Committee Meeting Marriott Hotel (301-590-0044)  

E-Print Network (OSTI)

/Registration - Sheraton Hotel 12:00pm ­ 10:00pm Students arrive throughout the day 11:00am Box lunches Sheraton Hotel ·Hill Top ·SSRL 5:15pm Shuttle Bus from hotels to SLAC ­ Top of the Hill 6:00pm ­ 6:30pm Opening General Transportation to Hotels and/or to Stanford Student Observatory 8:15pm­ 9:30pm Stanford Student Observatory Tour

88

InterContinental Hotels Group | Open Energy Information  

Open Energy Info (EERE)

InterContinental Hotels Group InterContinental Hotels Group Jump to: navigation, search Name InterContinental Hotels Group Place Salt Lake City, Utah Zip 84130 Website http://www.intercontinentalhot Coordinates 40.7°, -111.94° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":40.7,"lon":-111.94,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

89

ENERGY STAR Portfolio Manager Data Trends: Energy Use In Hotels  

NLE Websites -- All DOE Office Websites (Extended Search)

Hotels Hotels The U.S. Environmental Protection Agency's (EPA) ENERGY STAR Portfolio Manager is changing the way organizations track and manage energy. Because of this widespread market adoption, EPA has prepared the DataTrends series to examine benchmarking and trends in energy and water consumption in Portfolio Manager. To learn more, visit www.energystar.gov/DataTrends. Energy use intensity (EUI) ranges from less than 100 to more than 800 kBtu/ft 2 across all hotel buildings, with those at the 95th percentile using almost 4 times the energy of those at the 5th percentile. The distribution has a negative skew, which means the most energy intensive buildings are much further away from

90

WastetoEnergy using Fuel Cells Workshop Capital Hilton Hotel, Washington DC  

E-Print Network (OSTI)

nice hotel near the top from which the ski slopes drop to the lakeshore, and it is here in the early 1900's ­ spent time in the Koli region and at the mountain hotel in particular. They came. Looking from the mountain top hotel out toward the lake. #12;The reason for our visit also had something

91

Typically, hotel bathroom lights are left on between five to eight hours per occupied  

E-Print Network (OSTI)

, receptions, coffee breaks, ground transportation, and conference materials. You are responsible for all hotel costs. CONFERENCE HOTELS Crown Plaza Cabana 4290 El Camino Real Palo Alto, CA 94306 Do not call the hotel directly for reservations. All reservations will be handled through The DANI Group once your

92

Exploring user-producer interaction in an online community: the case of Habbo Hotel  

Science Conference Proceedings (OSTI)

This article attempts to explore the user-producer interaction in the online community of Habbo Hotel. Based on desk research, interviews, an online survey among more than 3000 Habbo Hotel users in The Netherlands and online discussion groups with ... Keywords: Habbo Hotel, The Netherlands, communication, online communities, online safety, user-generated content, user-producer interaction, virtual communities, web-based communities

Mijke Slot

2008-11-01T23:59:59.000Z

93

PART I  

NLE Websites -- All DOE Office Websites (Extended Search)

take advantage of travel discounts offered to Federal contractor employee travelers by AMTRAK, hotels, motels, or car rental companies, when use of such discounts would result in...

94

Microsoft Word - SECTION I - 08GO28308_Modification 599  

NLE Websites -- All DOE Office Websites (Extended Search)

take advantage of travel discounts offered to Federal contractor employee travelers by AMTRAK, hotels, motels, or car rental companies, when use of such discounts would result in...

95

Microsoft Word - DE-FE0004001 Full text of Clauses.doc  

NLE Websites -- All DOE Office Websites (Extended Search)

take advantage of travel discounts offered to Federal contractor employee travelers by AMTRAK, hotels, motels, or car rental companies, when use of such discounts would result in...

96

PART I SECTION B SUPPLIES AND SERVICES AND PRICE/COSTS DE-AC36...  

NLE Websites -- All DOE Office Websites (Extended Search)

take advantage of travel discounts offered to Federal contractor employee travelers by AMTRAK, hotels, motels, or car rental companies, when use of such discounts would result in...

97

Part I Section B Supplies and Services and Price/Costs  

NLE Websites -- All DOE Office Websites (Extended Search)

take advantage of travel discounts offered to Federal contractor employee travelers by AMTRAK, hotels, motels, or car rental companies, when use of such discounts would result in...

98

Travel and Entertainment All Airlines  

E-Print Network (OSTI)

, Flying Fields Travel Agencies and Tour Operators Bridge and Road Fees, Tolls Services (Utilities) Wire Institutions Securities Brokers /Dealers Insurance Sales, Underwriting and Premiums Lodging Hotels, Motels

Castillo, Steven P.

99

NIST - Bell Labs Workshop on Large-Scale Complex ...  

Science Conference Proceedings (OSTI)

... tree-like structure in these networks using traditional tools such as ... Information about Hotels/Motels, Food/Dining, Weather, Transportation can be ...

2012-06-06T23:59:59.000Z

100

Visitor Information, Boulder Laboratories  

Science Conference Proceedings (OSTI)

... Visitors must wear a visitor badge at all times while on the NIST campus. Hotels/Motels, NIST Boulder Tours. Food/Dining. Local restaurants. Weather ...

2013-08-23T23:59:59.000Z

Note: This page contains sample records for the topic "include hotels motels" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Hotel gets 1-yr. payback from propane-fired cogenerator  

SciTech Connect

A Philadelphia Ramada Inn recovered the costs of a $150,000 propane-fired cogenerator system within a year. The system reduced the energy consumed for hot water and air conditioning by 35% and reversed the high energy costs the hotel incurred when it was forced to shift from natural gas to electricity. The 170 horsepower system, which handles a variety of liquid and gaseous fuels as well as propane, replaces two boilers that were used to heat water. The hotel supplements cogenerated power with purchases from the utility. Waste heat is recaptured for space and water heating. The system's overall efficiency is 96%.

Barber, J.

1983-08-22T23:59:59.000Z

102

Spinning Reserve From Hotel Load Response: Initial Progress  

SciTech Connect

This project was motivated by the fundamental match between hotel space conditioning load response capability and power system contingency response needs. As power system costs rise and capacity is strained demand response can provide a significant system reliability benefit at a potentially attractive cost. At ORNL s suggestion, Digital Solutions Inc. adapted its hotel air conditioning control technology to supply power system spinning reserve. This energy saving technology is primarily designed to provide the hotel operator with the ability to control individual room temperature set-points based upon occupancy (25% to 50% energy savings based on an earlier study [Kirby and Ally, 2002]). DSI added instantaneous local load shedding capability in response to power system frequency and centrally dispatched load shedding capability in response to power system operator command. The 162 room Music Road Hotel in Pigeon Forge Tennessee agreed to host the spinning reserve test. The Tennessee Valley Authority supplied real-time metering equipment in the form of an internet connected Dranetz-BMI power quality meter and monitoring expertise to record total hotel load during both normal operations and test results. The Sevier County Electric System installed the metering. Preliminary testing showed that hotel load can be curtailed by 22% to 37% depending on the outdoor temperature and the time of day. These results are prior to implementing control over the common area air conditioning loads. Testing was also not at times of highest system or hotel loading. Full response occurred in 12 to 60 seconds from when the system operator s command to shed load was issued. The load drop was very rapid, essentially as fast as the 2 second metering could detect, with all units responding essentially simultaneously. Load restoration was ramped back in over several minutes. The restoration ramp can be adjusted to the power system needs. Frequency response testing was not completed. Initial testing showed that the units respond very quickly. Problems with local power quality generated false low frequency signals which required testing to be stopped. This should not be a problem in actual operation since the frequency trip points will be staggered to generate a droop curve which mimics generator governor response. The actual trip frequencies will also be low enough to avoid power quality problems. The actual trip frequencies are too low to generate test events with sufficient regularity to complete testing in a reasonable amount of time. Frequency response testing will resume once the local power quality problem is fully understood and reasonable test frequency settings can be determined. Overall the preliminary testing was extremely successful. The hotel response capability matches the power system reliability need, being faster than generation response and inherently available when the power system is under the most stress (times of high system and hotel load). Periodic testing is scheduled throughout the winter and spring to characterize hotel response capability under a full range of conditions. More extensive testing will resume when summer outdoor temperatures are again high enough to fully test hotel response.

Kueck, John D [ORNL; Kirby, Brendan J [ORNL

2008-11-01T23:59:59.000Z

103

Reserve asset values and the "hotelling valuation principle"  

E-Print Network (OSTI)

The Hotelling Valuation Principle, that the in-situ value of a mineral unit equals the current net price, is a special case of a more general relation. Tested against a set of recent Canadian sales of oil and gas reserves, ...

Adelman, Morris Albert

1992-01-01T23:59:59.000Z

104

The Philadelphia Marriott: A convention center flagship hotel  

SciTech Connect

This article describes the state-of-the-art HVAC system at the Philadelphia Marriott Hotel. Thermal comfort and indoor air quality are emphasized. The system uses a hybrid gas absorption/electric centrifugal chilled water plant, variable flow pumping, water-side economizers to provide free cooling, central air handling units with air-side economizers and flow monitoring equipment.

Shulman, M.S. [Giovanetti-Shulman Associates, Drexel Hill, PA (United States); Mattocks, J. [Mechanical Design International, Inc., Ellicott City, MD (United States)

1997-01-01T23:59:59.000Z

105

Stroppel Hotel Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Space Heating Low Temperature Geothermal Facility Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Stroppel Hotel Space Heating Low Temperature Geothermal Facility Facility Stroppel Hotel Sector Geothermal energy Type Space Heating Location Midland, South Dakota Coordinates 44.0716539°, -101.1554178° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

106

Solar Energy Program: Chapter from the Energy and Environmental Division Annual Report 1980  

E-Print Network (OSTI)

growth rate of energy use in the hotel and motel category isEnergy's San Francisco Operations Office's (DOE/SAN) overall management of commercial-building solar demonstration projects and hotel/

Energy and Environment Division

1981-01-01T23:59:59.000Z

107

Reference Buildings by Building Type: Small Hotel  

Energy.gov (U.S. Department of Energy (DOE))

In addition to the ZIP file for each building type, you can directly view the "scorecard" spreadsheet that summarizes the inputs and results for each location. This Microsoft Excel spreadsheet is also included in the ZIP file. For version 1.4, only the IDF file is included.

108

Reference Buildings by Building Type: Large Hotel  

Energy.gov (U.S. Department of Energy (DOE))

In addition to the ZIP file for each building type, you can directly view the "scorecard" spreadsheet that summarizes the inputs and results for each location. This Microsoft Excel spreadsheet is also included in the ZIP file. For version 1.4, only the IDF file is included.

109

Workshop on Renewable Energy Certificate (REC) Markets and Challenges Renaissance Washington Hotel, Washington, DC  

E-Print Network (OSTI)

Workshop on Renewable Energy Certificate (REC) Markets and Challenges Renaissance Washington Hotel Berkeley National Laboratory Paul Douglas, California Public Utilities Commission Paul Helgeson, Wisconsin

110

Reactivation or expansion of Hotel Baker Hydro plant. Feasibility assessment report  

SciTech Connect

The Hotel Baker Hydroelectric Power plant, built in 1928 at St. Charles, IL., has two generating units which until 1970 supplied the hotel with 100 kW output at 6 ft. head. The feasibility of reactivating, upgrading, or replacing these units to again supply power for the hotel was evaluated considering installation and operating costs, financing requirements, environmental impacts, and regulatory requirements. It was concluded that the reactivation project is marginally attractive only with full use of the power output by an expanded hotel and if electric utility rates increase at 8% per year. (LCL)

1979-03-01T23:59:59.000Z

111

An Analysis of the environmental content of Las Vegas Strip hotels.  

E-Print Network (OSTI)

??This study examines the environmental content of hotel properties websites. The central question of this study is whether Las Vegas Strip properties have gone green, (more)

Levey, Andrew M.

2007-01-01T23:59:59.000Z

112

An Investigation of sustainable environmental practices and consumer attitudes & behaviors toward hotel bathroom amenities.  

E-Print Network (OSTI)

??In the 1980s hotel operators became concerned with greening and sustainability. It was at this time the hospitality industry began focusing on energy efficiency and (more)

Bobbett, Edward James

2010-01-01T23:59:59.000Z

113

Green energy initiatives in the hotel industry: factors influencing adoption decisions.  

E-Print Network (OSTI)

??Adopting green energy initiatives is deemed significant in reducing the carbon footprint of the hotel industry. In general, energy-efficient and renewable energy technologies offer wide (more)

Halbe, Akanksha

2013-01-01T23:59:59.000Z

114

Energy saving thermostat  

SciTech Connect

A thermostat device is disclosed for motels/hotels requiring the guest to use a key to select a desired room temperature which in turn requires that the thermostat must be set back to a preset temperature when guest desires to lock the door to his motel/hotel room upon leaving the room.

Fodera, A.W.

1983-09-13T23:59:59.000Z

115

Impact of the Great East Japan Earthquake on Hotel Industry in Pacific Tohoku Prefectures: From spatio-temporal dependence of hotel availability  

E-Print Network (OSTI)

This paper investigates the impact of the Great Japan Earthquake (and subsequent tsunami turmoil) on socio-economic activities by using data on hotel opportunities collected from an electronic hotel booking service. A method to estimate both primary and secondary regional effects of a natural disaster on human behavior is proposed. It is confirmed that temporal variation in the regional share of available hotels before and after a natural disaster may be an indicator to measure the socio-economic impact at each district.

Sato, Aki-Hiro

2012-01-01T23:59:59.000Z

116

Hotel dual-cogeneration plant saving 33% on electricity costs  

SciTech Connect

Hotel Del Coronado in California has two cogeneration systems in operation, one gas turbine based, the other an advanced solar photovoltaic installation which cuts its electric bill by $400,000 per year. In order to make the new installation as unobstrusive as possible, the gas turbine and waste heat boiler units were placed underground. The sunlight-to-electricity efficiency of the photovoltaic cogeneration system is about 8% and the thermal conversion efficiency about 50%. That makes for an overall 58% cogeneration efficiency. The design uses silicon solar cells specially designed for concentrator application.

Stambler, I.

1983-09-01T23:59:59.000Z

117

Carlson Rezidor Hotel Group Maximizes Revenue Through Improved Demand Management and Price Optimization  

Science Conference Proceedings (OSTI)

Under changing market conditions for the hospitality industry, the Carlson Rezidor Hotel Group CRHG collaborated with JDA Software Group to use operations research to drive higher revenue for its hoteliers and to stay ahead of the competition. This highly ... Keywords: competitor prices, demand forecasting, hospitality, hotel, price elasticity, price optimization, revenue management

Pelin Pekgn; Ronald P. Menich; Suresh Acharya; Phillip G. Finch; Frederic Deschamps; Kathleen Mallery; Jim Van Sistine; Kyle Christianson; James Fuller

2013-01-01T23:59:59.000Z

118

Curriculum for B.S. in Restaurant, Hotel, and Institutional Management  

E-Print Network (OSTI)

Curriculum for B.S. in Restaurant, Hotel, and Institutional Management FIRST YEAR Fall Spring HUSC., Organization 3 NS 1410, Science of Nutrition 4 RHIM 2310, Intro. to Hospitality Mgmt. 3 RHIM 2308, Hotel, Facilities Management 3 ANSC 3404, Cons. Selec./Util. 4 Oral Communications* 3 RHIM 3390, Purchasing in Hosp

Rock, Chris

119

CEF06, Amathus Beach Hotel, Limassol, Cyprus, June 22-24, 2006  

E-Print Network (OSTI)

of Excellence in Low-energy Ion-Beam Research and Applications (LIBRA). Location NCSR "Demokritos" is located been reserved for workshop participants at the President Hotel, Kifissias Avenue, at a special rate by completing the attached form (download) and sending it to the hotel Reservations Department (Ms. Maria

Nagurney, Anna

120

Many exterior entry and walkway lights in residential and commercial  

E-Print Network (OSTI)

. E N V I R O N M E N T A L L Y S O U N D A N D E N E R G Y E F F I C I E N T #12;Hotel/motel staff, contractors, and utility staff can use the information on this system. Key next steps include: · Building Owners/Managers and Lighting Specifiers--Specify the LED Hybrid Outdoor Fixture. · Utility Staff

Note: This page contains sample records for the topic "include hotels motels" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

A room with a viewpoint: Using social norms to motivate environmental conservation in hotels  

E-Print Network (OSTI)

Two field experiments examined the effectiveness of signs requesting hotel guests participation in an environmental conservation program. Appeals employing descriptive norms (e.g., the majority of guests reuse their towels) proved superior to a traditional appeal widely used by hotels that focused solely on environmental protection. Moreover, normative appeals were most effective when describing group behavior that occurred in the setting that most closely matched individuals immediate situational circumstances (e.g., the majority of guests in this room reuse their towels), which we refer to as provincial norms. Theoretical and practical implications for managing proenvironmental efforts are discussed. Until recently, the greatest towel-related dilemma travelers faced was reflected in the old joke told by the nightclub comic, Henny Youngman, about the hotel where he had stayed the previous night: What a hotel: the towels were so big and fluffy that I could hardly close my suitcase. In recent years, however, the question of whether or not to remove hotel towels has been supplanted by the question of whether or not to reuse hotel towels during the course of ones stay. With the adoption of environmental programs by hotels, more and more travelers are finding themselves urged to reuse their towels to help conserve environmental resources by saving energy and reducing the amount of detergent-related pollutants released into the environment. *Noah J. Goldstein is assistant professor of behavioral sciences at the

Noah J. Goldstein; Robert B. Cialdini

2008-01-01T23:59:59.000Z

122

Alexis Park Hotel, Las Vegas Topic Group Meeting Participants were:  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Notes Tuesday, January 20, 1998 8:00-11:30 a.m. Notes Tuesday, January 20, 1998 8:00-11:30 a.m. Alexis Park Hotel, Las Vegas Topic Group Meeting Participants were: Audrey Adamson, UETC Daren Gilbert, State of Nevada James Baranski, State of New York Phil Marbut, Canadian Pacific Railway Kevin Blackwell, US DOT/FRA Bruce Marriott, US DOT/FRA Mike Butler, UETC Kevin Miller, CSX Transportation Sandy Covi, Union Pacific RR Markus Popa, US DOE-OCRWM Ray English, US DOE-NR David Schoendorfer, Norfolk Southern RR Bob Fronczak, AAR John Tijan, US DOT/FRA The group convened at approximately 8:00 a.m. Mr. Butler distributed a meeting agenda, welcomed participants and introduced himself as the new Rail Topic Group lead and facilitator. He introduced Item I, "Existing Business"; specifically the two matrices tasked to the Group by

123

Heating facilities for the MGM Grand Hotel, Reno, Nevada  

SciTech Connect

The MGM Grand Hotel-Reno is located adjacent to an area with a well-documented geothermal resource. Currently, there is a number of entities seeking to determine the exact nature of the resource at the MGM site. This report concerns itself with identifying current natural gas loads within the MGM complex which could be met by geothermal should a source become available. The two principle assumptions upon which the following material is based are (1) that a source of 190/sup 0/F or higher temperature water is available and (2) all systems discussed would be installed in parallel with existing systems. That is, existing systems would remain in place providing 100 percent backup for the geothermal systems.

1981-09-01T23:59:59.000Z

124

Glenwood Hot Springs Hotel Pool & Spa Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Hotel Pool & Spa Low Temperature Geothermal Facility Hotel Pool & Spa Low Temperature Geothermal Facility Jump to: navigation, search Name Glenwood Hot Springs Hotel Pool & Spa Low Temperature Geothermal Facility Facility Glenwood Hot Springs Hotel Sector Geothermal energy Type Pool and Spa Location Glenwood Springs, Colorado Coordinates 39.5505376°, -107.3247762° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

125

Emerging patterns of adaptive re-use : the new American House Hotel  

E-Print Network (OSTI)

This thesis aims to develop a design solution for the adaptive reuse of the American House Hotel that answers an architectural design challenge with technical responses. The process of actualization has been pushed a bit ...

Moody, Linda A

1984-01-01T23:59:59.000Z

126

Symes Hotel and Medicinal Springs Pool & Spa Low Temperature Geothermal  

Open Energy Info (EERE)

Symes Hotel and Medicinal Springs Pool & Spa Low Temperature Geothermal Symes Hotel and Medicinal Springs Pool & Spa Low Temperature Geothermal Facility Jump to: navigation, search Name Symes Hotel and Medicinal Springs Pool & Spa Low Temperature Geothermal Facility Facility Symes Hotel and Medicinal Springs Sector Geothermal energy Type Pool and Spa Location Hot Springs, Montana Coordinates 47.6091041°, -114.6687414° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

127

BERAC Meeting May 19-20, 2008 Hilton Hotel Gaithersburg, MD | U.S. DOE  

Office of Science (SC) Website

9-20, 2008 Hilton Hotel Gaithersburg, MD 9-20, 2008 Hilton Hotel Gaithersburg, MD Biological and Environmental Research Advisory Committee (BERAC) BERAC Home Meetings BERAC Minutes BERAC Minutes Archive Members Charges/Reports Charter .pdf file (40KB) BER Committees of Visitors BER Home Meetings BERAC Meeting May 19-20, 2008 Hilton Hotel Gaithersburg, MD Print Text Size: A A A RSS Feeds FeedbackShare Page BERAC Meeting May 19-20, 2008 Hilton Hotel Gaithersburg, MD Agenda .pdf file (17KB) Presentations Mike Hochella .ppt file (388KB), Environmental Remediation Sciences Division Committee of Visitors Report Jim Adelstein .ppt file (1.1MB), Report on the Low Dose Radiation Research Program Himadri Pakrasi .ppt file (22.3MB), Science Talk, Membrane Biology Grand Challenge Jeff Amthor .ppt file (11.7MB), Update on BER Program for Ecosystems

128

Proceedings of the 45th IEEE Conference on Decision & Control Manchester Grand Hyatt Hotel  

E-Print Network (OSTI)

Proceedings of the 45th IEEE Conference on Decision & Control Manchester Grand Hyatt Hotel San towards these two goals utilizing a minimal 3-CMG array to provide 646% singularity-free momentum

129

The Luxury casino hotel dynamic price strategy practices for the FIT customer segment.  

E-Print Network (OSTI)

??This research paper compares room rate luxury casino hotel pricing pattern between the periods of 4/1/2009 to 6/30/2009). A good price strategy can help a (more)

Chen, Lei

2009-01-01T23:59:59.000Z

130

Drainable evacuated tubular solar cooling system at Frenchman's Reef Hotel  

SciTech Connect

The Frenchman's Reef Hotel in the Virgin Islands operates its own total energy plant which has the capacity to satisfy the entire requirements of the 510-room hotel for electricity, desalinated drinking water and sewage treatment. The solar energy system consists of a 13,384 square foot array of drainable evacuated tube collectors arranged on three wings of the hotel. Solar heated water is supplied to a 200 ton absorption chiller which cools public rooms in the hotel. A programmable microprocessor controller oversees all functions of the solar energy system and monitors and records data which can be subsequently recovered locally or over the telephone, either as hard copy printout or on tape. The construction and startup of the array and system operating results are discussed. System heat losses are assessed. (LEW)

Platt, D.M.

1981-05-01T23:59:59.000Z

131

Volatility of hotel market fundamentals and the determinants of variations between markets  

E-Print Network (OSTI)

How can volatility as well as other dynamics and characteristics in hotel market fundamentals affecting risk be better understood? This paper explores that fundamental question along with other more specific questions that ...

Cason, Brian (Brian Paul)

2010-01-01T23:59:59.000Z

132

Luxury condos : an analysis of sales price and hotel amenities in Manhattan  

E-Print Network (OSTI)

The purpose of this research project is to examine the market pricing behavior of condos with hotel amenities in the Manhattan condo market. To do this, data was compiled from multiple sources to track variations in price ...

Dolan, Amelia Jane

2011-01-01T23:59:59.000Z

133

An attempt to value Canadian oil and natural gas reserves : an extension of the hotelling valuation principle .  

E-Print Network (OSTI)

??The importance of the Hotelling Valuation Principle (HVP) in economic study lies in its ability to examine and drive the decision of how much of (more)

Shumlich, Michael

2008-01-01T23:59:59.000Z

134

Energy End-Use Patterns in Full-Service Hotels: A Case Study  

SciTech Connect

The U.S. Department of Energy (DOE) recently initiated a program -- Commercial Building Partnerships (CBP) -- to work with private-sector companies in the design of highly-efficient retrofit and new construction projects. Pacific Northwest National Laboratory (PNNL) is conducting a project with a major hotel company to retrofit a full-service, large hotel with the goal of reducing energy consumption by at least 30%. The first step of the project was an intensive metering and monitoring effort aimed at understanding energy end use patterns in the hotel. About 10% of the guest rooms (32), as well as circuits for most of the end uses in public spaces (lighting, elevators, air handlers and other HVAC system components, and various equipment), were equipped with meters. Data are being collected at 1- or 5-minute intervals and downloaded on a monthly basis for analysis. This paper presents results from the first four months of the monitoring effort, which revealed energy end-use consumption patterns, variability of guest room energy use, daily load curves, monthly variations, and other aspects of hotel energy use. Metered end-use data for hotels at this level of detail are not available from any currently-available public sources. This study presents unique information and insight into energy end-use patterns in the lodging sector of commercial buildings and can also serve as a case study of a complex sub-metering project.

Placet, Marylynn; Katipamula, Srinivas; Liu, Bing; Dirks, James A.; Xie, YuLong; Sullivan, Greg; Walent, Jim; Williamson, Rebecca

2010-06-30T23:59:59.000Z

135

Stroppel Hotel Pool & Spa Low Temperature Geothermal Facility | Open Energy  

Open Energy Info (EERE)

Stroppel Hotel Pool & Spa Low Temperature Geothermal Facility Stroppel Hotel Pool & Spa Low Temperature Geothermal Facility Facility Stroppel Hotel Sector Geothermal energy Type Pool and Spa Location Midland, South Dakota Coordinates 44.0716539°, -101.1554178° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

136

Servidyne Systems and The Ritz Carlton Hotel Company: SPP Success Story |  

NLE Websites -- All DOE Office Websites (Extended Search)

Systems and The Ritz Carlton Hotel Company: SPP Success Systems and The Ritz Carlton Hotel Company: SPP Success Story Secondary menu About us Press room Contact Us Portfolio Manager Login Facility owners and managers Existing buildings Commercial new construction Industrial energy management Small business Service providers Service and product providers Verify applications for ENERGY STAR certification Design commercial buildings Energy efficiency program administrators Commercial and industrial program sponsors Associations State and local governments Federal agencies Tools and resources Training In This Section Campaigns Commercial building design Communications resources Energy management guidance Financial resources Portfolio Manager Products and purchasing Recognition Research and reports Service and product provider (SPP) resources

137

Red Lion Hotel Richland Hanford House Richland, Washington U. S. DEPARTMENT OF ENERGY  

NLE Websites -- All DOE Office Websites (Extended Search)

Lion Hotel Richland Hanford House Lion Hotel Richland Hanford House Richland, Washington U. S. DEPARTMENT OF ENERGY Performance Assessment Community of Practice Technical Exchange April 13 - 14, 2010 Performance Assessment Community of Practice Technical Exchange 1 Welcome Dear Participant, On behalf of the Department of Energy and the Savannah River National Laboratory, we welcome you to the Performance Assessment Community of Practice Technical Exchange. Each of you bring a wealth of experience from a variety of different perspectives that will be essential for the effective and compliant imple- mentation of performance and risk assessments in support of tank closure, site operations, and area completion projects. The Performance Assess-

138

SPP sales flyer for hospitality and hotels | ENERGY STAR Buildings & Plants  

NLE Websites -- All DOE Office Websites (Extended Search)

hospitality and hotels hospitality and hotels Secondary menu About us Press room Contact Us Portfolio Manager Login Facility owners and managers Existing buildings Commercial new construction Industrial energy management Small business Service providers Service and product providers Verify applications for ENERGY STAR certification Design commercial buildings Energy efficiency program administrators Commercial and industrial program sponsors Associations State and local governments Federal agencies Tools and resources Training In This Section Campaigns Commercial building design Communications resources Energy management guidance Financial resources Portfolio Manager Products and purchasing Recognition Research and reports Service and product provider (SPP) resources Success stories Target Finder Technical documentation

139

Proceedings of the 45th IEEE Conference on Decision & Control Manchester Grand Hyatt Hotel  

E-Print Network (OSTI)

Proceedings of the 45th IEEE Conference on Decision & Control Manchester Grand Hyatt Hotel San describing the left and right turn minimum radius paths of the vehicle. Utilizing this construction, a weak then be utilized to plan shortest path segments in the presence of obstacles in future work. In order to avoid

Barth, Eric J.

140

Fulfilled and missed requirements for online reservation systems: an empirical investigation of austrian and swiss hotels  

Science Conference Proceedings (OSTI)

Temporal data are a core element of a reservation. In this paper we formulate 10 requirements and 14 sub-requirements for handling temporal data in online hotel reservation systems (OHRS) from a usability viewpoint. We test the fulfillment of these requirements ... Keywords: B2C systems, requirements engineering, reservation systems, temporal data, tests, travel, usability

Gerhard F. Knolmayer, Viola Sini, Polina Chelnokova

2013-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "include hotels motels" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Geothermal feasibility study for hotel/apartment complex: Decker Land Development, Tucson, Arizona  

SciTech Connect

The commercial project studied consists of a 200-unit hotel and a 300-unit apartment complex, to be served by a common geothermal system. An additional 200-unit is assumed to be operational within seven years. The following aspects of the geothermal resource, project assumptions, geothermal utilization techniques, and energy analysis techniques.

1982-03-01T23:59:59.000Z

142

Changing How We Choose Hotels Would you pay more to stay in a  

E-Print Network (OSTI)

Fusion Energy Sciences Advisory Committee Meeting March 1-2, 2007 Marriott Hotel/301-590-0044 9751. Raymond L. Orbach, Under Secretary of Science 12:30 Lunch 1:30 Fusion Energy Sciences FY 2008 Budget Tom:45 Discussion of the New Charge FESAC 5:30 Adjourn #12;Fusion Energy Sciences Advisory Committee Meeting March 1

Soerens, Thomas

143

City of San Carlos Building Division  

E-Print Network (OSTI)

Residential: The construction of R2, R3, R3.1, and R4 buildings, except hotels and motels. C. Residential of any or all utilities (water, electrical, natural gas, or sewer); or the project provided no permanent

144

A Small-Business Guide: Lodging  

Science Conference Proceedings (OSTI)

Members of the small business community historically have had little contact with their utility providers. This guidebook was developed to facilitate communication between electric utilities and the motels and hotels in their communities. The Lodging guidebook is intended to familiarize readers with the business of owning and/or operating motels and hotels by providing a historic overview of the lodging industry and summarizing its current issues and challenges. The guide specifically focuses on delineat...

1996-12-24T23:59:59.000Z

145

Proceedings of the 45th IEEE Conference on Decision & Control ThAl8.6 Manchester Grand Hyatt Hotel  

E-Print Network (OSTI)

Proceedings of the 45th IEEE Conference on Decision & Control ThAl8.6 Manchester Grand Hyatt Hotel that the energy efficiency of wireless networks can be greatly improved by utilizing transmission control

Cassandras, Christos G.

146

Select-service hotels : a guide to understanding the lodging industry and one of its most attractive segments  

E-Print Network (OSTI)

This thesis serves as a pedagogical guide to the hospitality industry, and presents a broad overview of the unique issues that arise through the development, ownership and management of select-service franchised hotels. ...

Berger, Brandon B. (Brandon Brooks)

2007-01-01T23:59:59.000Z

147

Cost effective solar hot water system for econo-travel motor hotel located at Hampton, VA  

SciTech Connect

This paper gives the final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 2708 Mercury Boulevard, Hampton, Virginia. The description of the system along with the final cost breakdown, performance data and payback time are given. The payback time for the installed system will be approximately four (4) years instead of the 6.65 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for the laundry. As called for in the proposal to DOE, the success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.

1978-11-01T23:59:59.000Z

148

Cost effective solar hot water system for Econo-Travel Motor Hotel, Chesapeake, Virginia. Final report  

SciTech Connect

The final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 4725 W. Military Highway, Chesapeake, Virginia, is presented. The description of the system along with the final breakdown performance data and payback time are given. The payback time for the installed system will be approximately four (4) years instead of the 6.65 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for the laundry. As called for in the proposal to DOE, the success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.

1978-12-01T23:59:59.000Z

149

3,000 kW Suginoi Hotel geothermal power plant  

SciTech Connect

The Suginoi Hotel is located 200 m above sea level, in Beppu City, which is one of the largest hot spring resort area in Japan. In this hotel, there are some unique hot spring baths, which are interesting to visitors. In Beppu, there are numerous hot springs, some are call {open_quotes}Jigoku{close_quotes} (Hells). The main attraction in Beppu are the hell-like spots created by hot springs such as the Torando Hell, which erupt to a heights of more than 50 meters, The Blood Pond Hell which is bloody red due to red clay content. In yield, these hot springs rank second in the world next to those of Yellowstone National Park in the USA.

Kudo, Kisumi [Beppu Suginoi Hotel, Beppu (Japan)

1996-05-01T23:59:59.000Z

150

Cost effective solar hot water system for econo-travel motor hotel located at Hampton, VA  

DOE Green Energy (OSTI)

This paper gives the final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 2708 Mercury Boulevard, Hampton, Virginia. The description of the system along with the final cost breakdown, performance data and payback time are given. The payback time for the installed system will be approximately four (4) years instead of the 6.65 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for the laundry. As called for in the proposal to DOE, the success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.

Not Available

1978-11-01T23:59:59.000Z

151

Cost effective solar hot water system for Econo-Travel Motor Hotel, Chesapeake, Virginia. Final report  

DOE Green Energy (OSTI)

The final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 4725 W. Military Highway, Chesapeake, Virginia, is presented. The description of the system along with the final breakdown performance data and payback time are given. The payback time for the installed system will be approximately four (4) years instead of the 6.65 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for the laundry. As called for in the proposal to DOE, the success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.

Not Available

1978-12-01T23:59:59.000Z

152

Characterization of commercial building appliances. Final report  

SciTech Connect

This study focuses on ``other`` end-uses category. The purpose of this study was to determine the relative importance of energy end-use functions other than HVAC and lighting for commercial buildings, and to identify general avenues and approaches for energy use reduction. Specific energy consuming technologies addressed include non-HVAC and lighting technologies in commercial buildings with significant energy use to warrant detailed analyses. The end-uses include office equipment, refrigeration, water heating, cooking, vending machines, water coolers, laundry equipment and electronics other than office equipment. The building types include offices, retail, restaurants, schools, hospitals, hotels/motels, grocery stores, and warehouses.

Patel, R.F.; Teagan, P.W.; Dieckmann, J.T.

1993-08-01T23:59:59.000Z

153

Developing a localisation indicator for chain hotel websites: a Greek case study  

Science Conference Proceedings (OSTI)

Web visitors differ across regional, linguistic and country boundaries and their requirements are strongly influenced by their local cultural perspective. The localisation of a website is the process of adapting it to a particular language, culture and ... Keywords: Greece, business information systems, collectivism, cultural perspectives, culture, evaluation models, femininity, hospitality industry, hotel chains, hoteliers, individualism, internet, language, linguistic factors, local, localisation indicators, masculinity, power distance, quantitative measurement, tourism, uncertainty avoidance, websites, world wide web

Dimitris Kanellopoulos; Fotis Lazarinis

2010-03-01T23:59:59.000Z

154

Lodging | Open Energy Information  

Open Energy Info (EERE)

Lodging Lodging Jump to: navigation, search Building Type Lodging Definition Buildings used to offer multiple accommodations for short-term or long-term residents, including skilled nursing and other residential care buildings. Sub Categories motel or inn; hotel; dormitory, fraternity, or sorority; retirement home; nursing home, assisted living, or other residential care; convent or monastery; shelter, orphanage, or children's home; halfway house References EIA CBECS Building Types [1] References ↑ EIA CBECS Building Types U.S. Energy Information Administration (Oct 2008) Retrieved from "http://en.openei.org/w/index.php?title=Lodging&oldid=270114" Category: CBECS Building Types What links here Related changes Special pages Printable version Permanent link

155

2005 EIA-821 SURVEY: LINE-BY-LINE REFERENCE GUIDE  

U.S. Energy Information Administration (EIA) Indexed Site

Page 1 Page 1 2012 EIA-821 SURVEY: LINE-BY-LINE REFERENCE GUIDE Kerosene Line No. Sold directly to consumers for: 1 Residential Use (Non-Farm): * Backup generator * Home heating and cooking * Personal lawn equipment * EXCLUDE: Apartment buildings and Farmhouses 2 Commercial Use: * Apartment building * Bank * Casino * Church * College/School/Institution * Department/Retail store * Environmental clean-up service * Flushing fuel lines * Forestry service * Golf course * Government (Federal, State, local, and district; INCLUDE fuel used in vehicles) * Hazardous waste company * Hospital * Hotel/Motel * Landfill site government owned * Landscaping * Laundry company * Lumber yard that sells the lumber * Medical service * Port Authority/publicly owned port or loading dock

156

On-site fuel cell field test support program. Annual report Jul 81-Jun 82  

SciTech Connect

United continued this past year to assist the utilities and the Gas Research Institute in the review and selection of sites for data monitoring. Each of these sites will be instrumented and its energy requirements monitored and analyzed for one year prior to the selection of 40 Kilowatt fuel cell field test sites. Analyses in support of the selection of sites for instrumentation continued to show that many building sectors offered considerable market potential. These sectors include nursing home, health club, restaurant, industrial, hotel/motel and apartment.

Staniunas, J.W.; Merten, G.P.

1982-09-01T23:59:59.000Z

157

Valance heating/cooling system attains largest application in 1,000-room hotel  

SciTech Connect

Room temperatures in the 1,000 guest rooms of Chicago's Hyatt Regency Hotel are controlled by a valance heating and cooling system that functions by means of radiation and convection. The valances are mounted below the ceiling and consists of finned tubes and a drain tube contained within a wall-mounted enclosure. The finned tubes and drain are connected to a riser system, that is connected to a hot and cold water supply. The economics of the system is discussed and with no fans, motors, or blowers to run, energy is conserved. (MCW)

1976-08-01T23:59:59.000Z

158

Hotel Cedes 7 months' savings for total lighting retrofit  

SciTech Connect

In an unusual shared-savings agreement, the Hilton Florida Center at Orlando, where a retrofit program was begun two years ago, will give up all savings from a lighting retrofit program for seven months, avoiding upfront costs of equipment purchase, and will then become sole owner of the equipment and beneficiary of the savings. The four-month-old program has improved the lighting and cut electricity costs $2000 to $2500 per month, which would have been a six-month payback. Contracts for two other hotels are expected where retrofitting has begun. Retrofit details are given.

Warrock, A.M.

1983-07-11T23:59:59.000Z

159

Solar cooling system performance, Frenchman's Reef Hotel, Virgin Islands. Final report  

SciTech Connect

The operational and thermal performance of a variety of solar systems are described. The Solar Cooling System was installed in a hotel at St. Thomas, U. S. Virgin Islands. The system consists of the evacuated glass tube collectors, two 2500 gallon tanks, pumps, computerized controller, a large solar optimized industrial sized lithium bromide absorption chiller, and associated plumbing. Solar heated water is pumped through the system to the designed public areas such as lobby, lounges, restaurant and hallways. Auxiliary heat is provided by steam and a heat exchanger to supplement the solar heat.

Harber, H.

1981-09-01T23:59:59.000Z

160

Field Measurement of Heating System in a Hotel Building in Harbin  

E-Print Network (OSTI)

Heating energy consumption in winter is an important component of the whole building energy consumption in the severe cold zone in north China. This paper presents a heating water system of a hotel building in Harbin, finishes the testing of its heating energy consumption in winter under operational conditions, and presents an stimation index of the performance of an exchanger, pump and motor. Analysis of device running conditions based on testing data is conducted. Results show that low stream supply temperature and wide-range flow fluctuation mainly lead to unhealthy working conditions of the device and excessive energy consumption, and a corresponding improved method is presented.

Zhao, T.; Zhang, J.; Li, Y.

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "include hotels motels" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Transactions of the twenty-third water reactor safety information meeting to be held at Bethesda Marriott Hotel, Bethesda, Maryland, October 23--25, 1995  

SciTech Connect

This report contains summaries of papers on reactor safety research to be presented at the 23rd Water Reactor Safety Information Meeting at the Bethesda Marriott Hotel, Bethesda, Maryland, October 23--25, 1995. The summaries briefly describe the programs and results of nuclear safety research sponsored by the Office of Nuclear Regulatory, Research, US NRC. Summaries of invited papers concerning nuclear safety issues from US government laboratories, the electric utilities, the nuclear industry, and from foreign governments and industry are also included. The summaries have been compiled in one report to provide a basis for meaningful discussion and information exchange during the course of the meeting and are given in the order of their presentation in each session.

Monteleone, S. [comp.

1995-09-01T23:59:59.000Z

162

SPIE 's 4TH Annual Symposium on Smart Structures and Materials, paper 3041 -38, Catamaran Resort Hotel, San Diego,  

E-Print Network (OSTI)

Hotel, San Diego, CA, 2-6 March 97 LARGE-AMPLITUDE ROTARY INDUCED-STRAIN (LARIS) ACTUATOR PROOF-strain material stacks is proposed. The concept utilizes the theory of twist-warping coupling in thin-wall open-amplifier utilizing the warping-torsion coupling of an open tube, is a viable design option, of great constructive

Giurgiutiu, Victor

163

Hotel archiphilia  

E-Print Network (OSTI)

Jean-Francois de Bastide's mid-eighteenth century novel, The Little House, describes an erotic encounter between a persistent man, and a reluctant woman. More remarkably, the novel introduces a third character, the estate ...

Jusczyk, Thaddeus P

2009-01-01T23:59:59.000Z

164

Combined Heating and Power Using Microturbines in a Major Urban Hotel  

SciTech Connect

This paper describes the results of a cooperative effort to install and operate a Cooling, Heating and Power (CHP) System at a major hotel in San Francisco, CA. The packaged CHP System integrated four microturbines, a double-effect absorption chiller, two fuel gas boosters, and the control hardware and software to ensure that the system operated predictably, reliably, and safely. The chiller was directly energized by the recycled hot exhaust from the microturbines, and could be configured to provide either chilled or hot water. As installed, the system was capable of providing up to 227 kW of net electrical power and 142 Refrigeration Tons (RT) of chilled water at a 59oF (15oC) ambient temperature. For the year, the CHP efficiency was 54 percent. Significant lessons learned from this test and verification project are discussed as well as measured performance and economic considerations.

Sweetser, Richard [Exergy Partners Corp.; Wagner, Timothy [United Technologies Research Center (UTRC); Leslie, Neil [Gas Technology Institute; Stovall, Therese K [ORNL

2009-01-01T23:59:59.000Z

165

Solar-cooling-system performance, Frenchman's Reef Hotel, St. Thomas, US Virgin Islands. Final report  

DOE Green Energy (OSTI)

The Solar Cooling System installed in the Frenchman's Reef Resort Hotel Test Site, St. Thomas, US Virgin Islands, used 956 Sunmaster Corporation evacuated glass tube collector modules which provide an effective solar collector aperture of 13,384 square feet. The system consists of the collectors, two 2500 gallon tanks, pumps, an Andover Controls Corporation computerized controller, a large solar optimized Carrier Corporation industrial sized lithium bromide absorption chiller, and associated plumbing. Solar heated water is pumped through the system to the designed public areas such as lobby, lounges, restaurant and hallways. Auxiliary heat is provided by steam and a heat exchanger to supplement the solar heat. The system, its operation sequence, and performance are described.

Harber, H.

1981-09-25T23:59:59.000Z

166

Shared-savings cuts hotel's losses from EMS removal  

SciTech Connect

A shared-savings contract will minimize the Myrtle Beach, SC Downtown Holiday Inn's losses of replacing a poorly performing Energy Master energy-management system with Scientific Atlanta equipment. The contract with Energy Master Inc. (EMI), which saved Holiday Inn the $80,000 to $90,000 purchase price, also permitted removal (a year after installation) of the equipment when it failed to generate energy savings. A dispute between Associated Energy Consultants (AEC), which was to receive half the savings in exchange for arranging the equipment financing, is described. At $51,745, the 262-point Scientific Atlanta system should have a 1.7-year payback. The hotel's electric bills were $2000 a month lower during the first three months of operation. (DCK)

Galvin, C.

1982-11-08T23:59:59.000Z

167

Train directions from Newark Airport to Nassau Inn or Palmer House Hotel Train is the most convenient way to get to Princeton from EWR. From the terminals at  

E-Print Network (OSTI)

Train directions from Newark Airport to Nassau Inn or Palmer House Hotel Train is the most://tinyurl.com/yc8g3rf or the Palmer House http://www.princeton.edu/palmerhouse/images/map.jpg Train directions from

168

Buildings Energy Data Book  

Buildings Energy Data Book (EERE)

3.1 Commercial Sector Energy Consumption 3.1 Commercial Sector Energy Consumption 3.2 Commercial Sector Characteristics 3.3 Commercial Sector Expenditures 3.4 Commercial Environmental Emissions 3.5 Commercial Builders and Construction 3.6 Office Building Markets and Companies 3.7 Retail Markets and Companies 3.8 Hospitals and Medical Facilities 3.9 Educational Facilities 3.10 Hotels/Motels 4Federal Sector 5Envelope and Equipment 6Energy Supply 7Laws, Energy Codes, and Standards 8Water 9Market Transformation Glossary Acronyms and Initialisms Technology Descriptions Building Descriptions Other Data Books Biomass Energy Transportation Energy Power Technologies Hydrogen Download the Entire Book Skip down to the tables Chapter 3 focuses on energy use in the commercial sector. Section 3.1 covers primary and site energy consumption in commercial buildings, as well as the delivered energy intensities of various building types and end uses. Section 3.2 provides data on various characteristics of the commercial sector, including floorspace, building types, ownership, and lifetimes. Section 3.3 provides data on commercial building expenditures, including energy prices. Section 3.4 covers environmental emissions from the commercial sector. Section 3.5 briefly addresses commercial building construction and retrofits. Sections 3.6, 3.7, 3.8, 3.9, and 3.10 provide details on select commercial buildings types, specifically office and retail space, medical facilities, educational facilities, and hotels and motels.

169

Nuclear Energy Research Advisory Committee Meeting April 15-16, 2002, Marriott Crystal City Hotel, Arlington, Virginia  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

15-16, 2002, Marriott Crystal City Hotel, Arlington, Virginia 15-16, 2002, Marriott Crystal City Hotel, Arlington, Virginia NERAC members present: John Ahearne (Monday only) Robert Long Thomas Cochran Warren F. Miller, Jr. Joseph Comfort Benjamin F. Montoya Michael L. Corradini Sekazi Mtingwa Jose Luis Cortez Lura Powell Maureen S. Crandall Richard Reba (Tuesday only) Allen Croff Joy Rempe James Duderstadt (Chair) Daniel C. Sullivan (Monday morning only) Steve Fetter John Taylor Beverly Hartline Ashok Thadani (ad hoc; Monday only) Leslie Hartz Charles E. Till Andrew Klein Neil Todreas (Tuesday only) Dale Klein (Monday only) NERAC members absent: Marvin Fertel Allen Sessoms J. Bennett Johnston C. Bruce Tarter Linda C. Knight Joan Woodard Also present: Ralph Bennett, Director for Advanced Nuclear Energy, Idaho National Engineering and

170

Cost effective solar hot water system for Econo-Travel Motor Hotel located at Bluefield, West Virginia. Final report  

SciTech Connect

The final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 3400 Cumberland Road, Bluefield, West Virginia. The description of the system along with the final breakdown performance data and payback time are given. The payback time for the installed system will be approximately five (5) years instead of the 7.73 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for the laundry. The success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.

1979-07-01T23:59:59.000Z

171

Cost effective solar hot water system for Econo-Travel Motor Hotel located at Richmond, Virginia. Final report  

SciTech Connect

The final report is presented of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 5408 Williamsburg Road, Richmond, Virginia. The description of the system is given along with the final cost breakdown, expected performance data and expected payback time for the installed system is estimated to be approximately five (5) years instead of the 6.65 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for the laundry. The success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.

1979-09-01T23:59:59.000Z

172

Cost effective solar hot water system for Econo-Travel Motor Hotel located at Woodbrdge, VA. Final report  

SciTech Connect

The final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 13317 Gordon Boulevard, Woodbridge, Virginia is given. The description of the system along with the final breakdown, performance data and payback time are given. The payback time for the installed system will be approximately four (4) years instead of the 7.2 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for the laundry. As called for in the proposal to DOE, the success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.

1978-11-01T23:59:59.000Z

173

Cost effective solar hot water system for Econo-Travel Motor Hotel located at Bluefield, West Virginia. Final report  

DOE Green Energy (OSTI)

The final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 3400 Cumberland Road, Bluefield, West Virginia. The description of the system along with the final breakdown performance data and payback time are given. The payback time for the installed system will be approximately five (5) years instead of the 7.73 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for the laundry. The success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.

Not Available

1979-07-01T23:59:59.000Z

174

Cost effective solar hot water system for Econo-Travel Motor Hotel located at Richmond, Virginia. Final report  

DOE Green Energy (OSTI)

The final report is presented of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 5408 Williamsburg Road, Richmond, Virginia. The description of the system is given along with the final cost breakdown, expected performance data and expected payback time for the installed system is estimated to be approximately five (5) years instead of the 6.65 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for the laundry. The success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.

Not Available

1979-09-01T23:59:59.000Z

175

Social media marketing in the hospitality industry: The role of benefits in increasing brand community participation and the impact of participation on consumer trust and commitment toward hotel and restaurant brands.  

E-Print Network (OSTI)

??Online community is an effective tool for building the relationship with consumers. Many hospitality firms (i.e., hotels and restaurants) have utilized online communities a new (more)

Kang, Juhee

2011-01-01T23:59:59.000Z

176

Test and Reconstruction of Air Conditioning System in a Hotel Lobby  

E-Print Network (OSTI)

Two air conditioning systems are equipped in a hotel lobby. It is found from the field test that the actual air rate is 40% and 16% of the nominal value, respectively, of the two systems, which is far lower than the design requirement. The air rate of the outlets varies greatly, and the coefficient of uniformity is 129.1% and 111.6% respectively of the two systems. Air distribution in the lobby is bad and thermal comfort is poor. Moreover, sharp reduction of return air makes portions of fresh air increase, which will lead to high energy consumption. Reconstruction is carried out to improve the thermal environment with the assistance of the CFD method. First, the original system is simulated by CFD method to verify the CFD method and propose modification suggestions. Then air conditioning load and air rate of the lobby is recalculated and duct redesigned. Simulation results show that the air distribution and thermal comfort of the improved scheme can meet the design requirement. The reconstructed system has been running for about two years and has shown good performance.

Wang, G.; Hu, Y.; Hu, S.; Chen, Q.

2006-01-01T23:59:59.000Z

177

Initial Study of Solar Control Film in a Hotel Guest Room in Winter  

E-Print Network (OSTI)

In recent years, energy-efficient facilities have prevailed in the Hong Kong and China markets. Many of these facilities claim to generate considerable energy and money savings. Hoteliers, however, find that there is a lack of independent and local studies about energy performance and its related financial savings and environmental improvement brought by those facilities, such as heat pumps, solar-control film on the window, sensor and dimmer for lighting control, etc. Nevertheless, there is a lack of reliable and independent data about the energy performance and economic viability of the solar-control film applied in a real environment. In many situations, consumers are only given the laboratory's result of this energy saving facility. Research was carried out in summer to estimate its positive effect on energy saving. There is also a paucity of experiments conducted in winter to show its negative effect in cold weather. This study carries out an experiment in hotel guest rooms in winter in order to estimate the energy and lighting performance of solar-control film in winter. This experiment was conducted when the illuminance under 1000lux, the average visible light transmittance for the film was 49.8%, and with very low solar radiation being transmitted into indoor environment. Under these situations, the study found that the effect of solar energy passing through the film coating in the guest room can be neglected. Instead, the film can act as a layer to prevent heat to transmit to the outdoors, just like the greenhouse effect.

Chan, W. C.; Chen, Y.; Mak, B.; Li, D.; Huang, Y.; Xie, H.; Hou, G.

2006-01-01T23:59:59.000Z

178

Energy Consumption Measuring and Diagnostic Analysis of Air-conditioning Water System in a Hotel Building in Harbin  

E-Print Network (OSTI)

This paper introduces an air-conditioning water system in a hotel building in Harbin, finishes its air-conditioning energy consumption measurement in summer conditions, and presents an estimation index of performance of chiller, pump and motor. By means of testing data analysis, it is indicated that several problems such as unsuitable operation schedule of the chiller, low COP, irrational matching of pump and motor, unbalanced conditions of chilled water flow, and low working stability and efficiency ratio of the pump are existent. The paper presents suggestions for improvement with relevance based on the induction and analysis of system fault found in measurements.

Zhao, T.; Zhang, J.; Li, Y.

2006-01-01T23:59:59.000Z

179

An analysis of the performance of certification schemes in the hotel sector in terms of CO2 emissions reduction.  

E-Print Network (OSTI)

, Selina Hext, Freya Roe, Sarah Farmer, Gary Watson and Jason Maynard and Howard Carter on making it possible for me to continue my studies. Thank you for the incredible friendships I have made over the years in Cambridge which I hope will last... 8 xiii List of Publications Peer Reviewed Conference papers Houlihan Wiberg, A., Baker, N.V., 20 08a. 305: Certification in The Hotel Sector; Does It Actually Reduce Global CO2 Emissions? In: PLEA 2008 25th Conference on Passive...

Houlihan-Wiberg, Aoife Anne-marie

2010-07-18T23:59:59.000Z

180

Appendix F Cultural Resources, Including  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Appendix F Appendix F Cultural Resources, Including Section 106 Consultation STATE OF CALIFORNIA - THE RESOURCES AGENCY EDMUND G. BROWN, JR., Governor OFFICE OF HISTORIC PRESERVATION DEPARTMENT OF PARKS AND RECREATION 1725 23 rd Street, Suite 100 SACRAMENTO, CA 95816-7100 (916) 445-7000 Fax: (916) 445-7053 calshpo@parks.ca.gov www.ohp.parks.ca.gov June 14, 2011 Reply in Reference To: DOE110407A Angela Colamaria Loan Programs Office Environmental Compliance Division Department of Energy 1000 Independence Ave SW, LP-10 Washington, DC 20585 Re: Topaz Solar Farm, San Luis Obispo County, California Dear Ms. Colamaria: Thank you for seeking my consultation regarding the above noted undertaking. Pursuant to 36 CFR Part 800 (as amended 8-05-04) regulations implementing Section

Note: This page contains sample records for the topic "include hotels motels" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Countries Gasoline Prices Including Taxes  

Gasoline and Diesel Fuel Update (EIA)

Countries (U.S. dollars per gallon, including taxes) Countries (U.S. dollars per gallon, including taxes) Date Belgium France Germany Italy Netherlands UK US 01/13/14 7.83 7.76 7.90 8.91 8.76 8.11 3.68 01/06/14 8.00 7.78 7.94 8.92 8.74 8.09 3.69 12/30/13 NA NA NA NA NA NA 3.68 12/23/13 NA NA NA NA NA NA 3.63 12/16/13 7.86 7.79 8.05 9.00 8.78 8.08 3.61 12/9/13 7.95 7.81 8.14 8.99 8.80 8.12 3.63 12/2/13 7.91 7.68 8.07 8.85 8.68 8.08 3.64 11/25/13 7.69 7.61 8.07 8.77 8.63 7.97 3.65 11/18/13 7.99 7.54 8.00 8.70 8.57 7.92 3.57 11/11/13 7.63 7.44 7.79 8.63 8.46 7.85 3.55 11/4/13 7.70 7.51 7.98 8.70 8.59 7.86 3.61 10/28/13 8.02 7.74 8.08 8.96 8.79 8.04 3.64 10/21/13 7.91 7.71 8.11 8.94 8.80 8.05 3.70 10/14/13 7.88 7.62 8.05 8.87 8.74 7.97 3.69

182

Charles Motel & Bathhouse Pool & Spa Low Temperature Geothermal...  

Open Energy Info (EERE)

Generation 1.00x109 Btuyr 0.30 GWhyr Delat T 5.00 F Load Factor 0.38 Contact Kathy Clark; 505-894-7154 References Oregon Institute of Technology's Geo-Heat Center1 Charles...

183

Solar-cooling-system performance, Frenchman's Reef Hotel, St. Thomas, US Virgin Islands. Final report  

SciTech Connect

The Solar Cooling System installed in the Frenchman's Reef Resort Hotel Test Site, St. Thomas, US Virgin Islands, used 956 Sunmaster Corporation evacuated glass tube collector modules which provide an effective solar collector aperture of 13,384 square feet. The system consists of the collectors, two 2500 gallon tanks, pumps, an Andover Controls Corporation computerized controller, a large solar optimized Carrier Corporation industrial sized lithium bromide absorption chiller, and associated plumbing. Solar heated water is pumped through the system to the designed public areas such as lobby, lounges, restaurant and hallways. Auxiliary heat is provided by steam and a heat exchanger to supplement the solar heat. The system, its operation sequence, and performance are described.

Harber, H.

1981-09-25T23:59:59.000Z

184

SLAC National Accelerator Laboratory - Accommodations  

NLE Websites -- All DOE Office Websites (Extended Search)

4.3 14 Super 8 3200 El Camino Real, Palo Alto 650-493-9085 4.7 15 Hotel California 2431 Ash St., Palo Alto 650-322-7666 5.0 16 Coronet Motel 2455 El Camino Real, Palo Alto...

185

St. Johns River Water Management District 4049 Reid Street P.O. Box 1429 Palatka, FL 32178-1429  

E-Print Network (OSTI)

, ground or surface water and· water from public and private utilities. Additional information Irrigation withdrawn from ground or surface· water, from a private well or pump, or from a public or private utility or transient housing units, hotel and motel units, and public medians and rights-of-way. #12;St. Johns River

Watson, Craig A.

186

Morbidity and Mortality Weekly Report Weekly June 6, 2003 / Vol. 52 / No. 22  

E-Print Network (OSTI)

underscore the utility of these data for public- health decision making and the need for increased training,131 inspections; the majority (67.5%) occurred in pools for which no pool type (e.g., hotel/motel) was speci- fied

187

Trends in Commercial Buildings--Overview  

U.S. Energy Information Administration (EIA) Indexed Site

Home > Trends in Commercial Buildings > Commercial Home > Trends in Commercial Buildings > Commercial Buildings Energy Consumption Survey Survey Methodology Sampling Error, Standard Errors, and Relative Standard Errors The Commercial Buildings Energy Consumption Survey The commercial sector consists of business establishments and other organizations that provide services. The sector includes service businesses, such as retail and wholesale stores, hotels and motels, restaurants, and hospitals, as well as a wide range of buildings that would not be considered “commercial” in a traditional economic sense, such as public schools, correctional institutions, and religious and fraternal organizations. Excluded from the sector are the goods-producing industries: manufacturing, agriculture, mining, forestry and fisheries, and construction.

188

Impacts of the 2009 IECC for Residential Buildings at State Level - Rhode Island  

NLE Websites -- All DOE Office Websites (Extended Search)

Rhode Island Rhode Island September 2009 Prepared by Pacific Northwest National Laboratory for the U.S. Department of Energy Building Energy Codes Program BUILDING ENERGY CODES PROGRAM IMPACTS OF THE 2009 IECC FOR RESIDENTIAL BUILDINGS IN RHODE ISLAND BUILDING ENERGY CODES PROGRAM IMPACTS OF THE 2009 IECC FOR RESIDENTIAL BUILDINGS IN RHODE ISLAND Analysis of 2009 International Energy Conservation Code Requirements for Residential Buildings in Rhode Island Summary Rhode Island has adopted the 2009 International Energy Conservation Code (IECC). Overview of the 2009 IECC The IECC scope includes residential single-family housing and multifamily housing three stories or less above- grade intended for permanent living (hotel/motel is not "residential"). The code applies to new buildings and

189

Impacts of the 2009 IECC for Residential Buildings at State Level - Illinois  

NLE Websites -- All DOE Office Websites (Extended Search)

Illinois Illinois September 2009 Prepared by Pacific Northwest National Laboratory for the U.S. Department of Energy Building Energy Codes Program BUILDING ENERGY CODES PROGRAM IMPACTS OF THE 2009 IECC FOR RESIDENTIAL BUILDINGS IN ILLINOIS BUILDING ENERGY CODES PROGRAM IMPACTS OF THE 2009 IECC FOR RESIDENTIAL BUILDINGS IN ILLINOIS Analysis of 2009 International Energy Conservation Code Requirements for Residential Buildings in Illinois Summary Illinois recently adopted the 2009 International Energy Conservation Code (IECC). Overview of the 2009 IECC The IECC scope includes residential single-family housing and multifamily housing three stories or less above- grade intended for permanent living (hotel/motel is not "residential"). The code applies to new buildings and

190

Science Accelerator content now includes multimedia  

Office of Scientific and Technical Information (OSTI)

Science Accelerator content now includes multimedia Science Accelerator has expanded its suite of collections to include ScienceCinema, which contains videos produced by the U.S....

191

Petroleum Gasoline & Distillate Needs Including the Energy ...  

U.S. Energy Information Administration (EIA)

Home > Petroleum > Analysis > Petroleum Gasoline & Distillate Needs Including the Energy Independence and Security Act (EISA) ...

192

Petroleum Gasoline & Distillate Needs Including the Energy ...  

U.S. Energy Information Administration (EIA)

Petroleum Gasoline & Distillate Needs Including the Energy Independence and Security Act (EISA) Impacts

193

Differential impact of gas shortages and fuel-price increases on demand: the case of the hotel industry in New York State  

SciTech Connect

The authors assess the impact of the energy crisis on the lodging industry in New York (excluding New York City) by estimating the effects of two related, but not necessarily correlated, variables: gas shortages and energy price increases. Strong evidence supports the conclusion that energy shortages dampen hotel demand while price increases encourage international, intrastate, and interstate shifts in distance distributions of travel destinations as well as changes in number of trips and length of stay, resulting in a slight aggregate increase in demand. Recent industry data relating to occupancy rates and profitability seem to support this conclusion. 16 references, 2 tables.

Arbel, A. (Cornell Univ., Ithaca, NY); Ravid, A.

1983-04-01T23:59:59.000Z

194

Effective May 1, 2013, UT System rolled out the use of Concur for online booking of business travel. The University of Texas at Dallas faculty and staff can utilize one simple tool to book their flights, car rentals, and hotel stays.  

E-Print Network (OSTI)

. The University of Texas at Dallas faculty and staff can utilize one simple tool to book their flights, car rentals, and hotel stays. Advantages of Booking through Concur: Ease of booking all travel necessities Personal Credit Card (for hotels or non-direct bill car rentals) #12;#12;Travel Arrangers and Assistants

O'Toole, Alice J.

195

70972 Federal Register / Vol. 76, No. 221 / Wednesday, November 16, 2011 / Notices (including hours and cost) of the  

E-Print Network (OSTI)

and cost) of the proposed collection of information; (c) ways to enhance the quality, utility, and clarity. ADDRESSES: The Council meeting will be held at the Hilton Hotel, 500 West Third Ave., Anchorage, AK

196

Gas storage materials, including hydrogen storage materials  

DOE Patents (OSTI)

A material for the storage and release of gases comprises a plurality of hollow elements, each hollow element comprising a porous wall enclosing an interior cavity, the interior cavity including structures of a solid-state storage material. In particular examples, the storage material is a hydrogen storage material such as a solid state hydride. An improved method for forming such materials includes the solution diffusion of a storage material solution through a porous wall of a hollow element into an interior cavity.

Mohtadi, Rana F; Wicks, George G; Heung, Leung K; Nakamura, Kenji

2013-02-19T23:59:59.000Z

197

Intentionally Including - Engaging Minorities in Physics Careers |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Intentionally Including - Engaging Minorities in Physics Careers Intentionally Including - Engaging Minorities in Physics Careers Intentionally Including - Engaging Minorities in Physics Careers April 24, 2013 - 4:37pm Addthis Joining Director Dot Harris (second from left) were Marlene Kaplan, the Deputy Director of Education and director of EPP, National Oceanic and Atmospheric Administration, Claudia Rankins, a Program Officer with the National Science Foundation and Jim Stith, the past Vice-President of the American Institute of Physics Resources. Joining Director Dot Harris (second from left) were Marlene Kaplan, the Deputy Director of Education and director of EPP, National Oceanic and Atmospheric Administration, Claudia Rankins, a Program Officer with the National Science Foundation and Jim Stith, the past Vice-President of the

198

Transmission line including support means with barriers  

DOE Patents (OSTI)

A gas insulated transmission line includes an elongated outer sheath, a plurality of inner conductors disposed within and extending along the outer sheath, and an insulating gas which electrically insulates the inner conductors from the outer sheath. A support insulator insulatably supports the inner conductors within the outer sheath, with the support insulator comprising a main body portion including a plurality of legs extending to the outer sheath, and barrier portions which extend between the legs. The barrier portions have openings therein adjacent the main body portion through which the inner conductors extend.

Cookson, Alan H. (Pittsburgh, PA)

1982-01-01T23:59:59.000Z

199

Quest Hotel and Travel  

Science Conference Proceedings (OSTI)

... Waterfront. They serve BWI Airport/Amtrak, Penn Station Baltimore, Reagan National Airport and Dulles Airport. Airport ...

2013-02-21T23:59:59.000Z

200

Reiz Continental Hotel  

E-Print Network (OSTI)

WORKSHOP OBJECTIVES:> To proffer solution to the energy problems in Africa by providing a forum for exchange of ideas by major stake holders.:> To address important aspects of the implementation of Renewable Energy Programmes in Africa.:> Explore emerging policy issues, regulations and implementation frameworks for the development of renewable energy and energy efficiency markets in Africa.:> Public awareness creation among poiicy makers, investors and the generai public on the potentials of renewable energy and energy efficiency in Africa SCOPE OF WORKSHOP:> State-of-the-art lectures to be delivered by seasoned experts in renewable energy in such areas as: Sea Water desalination Solar drying (food & cash crops,

University Nigeria; Sustalnable Economie

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "include hotels motels" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

DISASTER POLICY Including Extreme Emergent Situations (EES)  

E-Print Network (OSTI)

on the ACGME website with information relating to the ACGME response to the disaster. 3. The University-specific Program Requirements. Defined Responsibilities Following the Declaration of a Disaster or Extreme EmergentPage 123 DISASTER POLICY Including Extreme Emergent Situations (EES) The University of Connecticut

Oliver, Douglas L.

202

Buildings Included on EMS Reports"  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Office of Legacy Management Office of Legacy Management Buildings Included on EMS Reports" "Site","Property Name","Property ID","GSF","Incl. in Water Baseline (CY2007)","Water Baseline (sq. ft.)","Water CY2008 (sq. ft.)","Water CY2009 (sq. ft.)","Water Notes","Incl. in Energy Baseline (CY2003)","Energy Baseline (sq. ft.)","CY2008 Energy (sq. ft.)","CY2009 Energy (sq. ft.)","Energy Notes","Included as Existing Building","CY2008 Existing Building (sq. ft.)","Reason for Building Exclusion" "Column Totals",,"Totals",115139,,10579,10579,22512,,,3183365,26374,115374,,,99476 "Durango, CO, Disposal/Processing Site","STORAGE SHED","DUD-BLDG-STORSHED",100,"no",,,,,"no",,,,"OSF","no",,"Less than 5,000 GSF"

203

Power generation method including membrane separation  

SciTech Connect

A method for generating electric power, such as at, or close to, natural gas fields. The method includes conditioning natural gas containing C.sub.3+ hydrocarbons and/or acid gas by means of a membrane separation step. This step creates a leaner, sweeter, drier gas, which is then used as combustion fuel to run a turbine, which is in turn used for power generation.

Lokhandwala, Kaaeid A. (Union City, CA)

2000-01-01T23:59:59.000Z

204

Electric power monthly, September 1990. [Glossary included  

SciTech Connect

The purpose of this report is to provide energy decision makers with accurate and timely information that may be used in forming various perspectives on electric issues. The power plants considered include coal, petroleum, natural gas, hydroelectric, and nuclear power plants. Data are presented for power generation, fuel consumption, fuel receipts and cost, sales of electricity, and unusual occurrences at power plants. Data are compared at the national, Census division, and state levels. 4 figs., 52 tabs. (CK)

1990-12-17T23:59:59.000Z

205

Nuclear reactor shield including magnesium oxide  

DOE Patents (OSTI)

An improvement in nuclear reactor shielding of a type used in reactor applications involving significant amounts of fast neutron flux, the reactor shielding including means providing structural support, neutron moderator material, neutron absorber material and other components as described below, wherein at least a portion of the neutron moderator material is magnesium in the form of magnesium oxide either alone or in combination with other moderator materials such as graphite and iron.

Rouse, Carl A. (Del Mar, CA); Simnad, Massoud T. (La Jolla, CA)

1981-01-01T23:59:59.000Z

206

Thermovoltaic semiconductor device including a plasma filter  

DOE Patents (OSTI)

A thermovoltaic energy conversion device and related method for converting thermal energy into an electrical potential. An interference filter is provided on a semiconductor thermovoltaic cell to pre-filter black body radiation. The semiconductor thermovoltaic cell includes a P/N junction supported on a substrate which converts incident thermal energy below the semiconductor junction band gap into electrical potential. The semiconductor substrate is doped to provide a plasma filter which reflects back energy having a wavelength which is above the band gap and which is ineffectively filtered by the interference filter, through the P/N junction to the source of radiation thereby avoiding parasitic absorption of the unusable portion of the thermal radiation energy.

Baldasaro, Paul F. (Clifton Park, NY)

1999-01-01T23:59:59.000Z

207

Models of Procyon A including seismic constraints  

E-Print Network (OSTI)

Detailed models of Procyon A based on new asteroseismic measurements by Eggenberger et al (2004) have been computed using the Geneva evolution code including shellular rotation and atomic diffusion. By combining all non-asteroseismic observables now available for Procyon A with these seismological data, we find that the observed mean large spacing of 55.5 +- 0.5 uHz favours a mass of 1.497 M_sol for Procyon A. We also determine the following global parameters of Procyon A: an age of t=1.72 +- 0.30 Gyr, an initial helium mass fraction Y_i=0.290 +- 0.010, a nearly solar initial metallicity (Z/X)_i=0.0234 +- 0.0015 and a mixing-length parameter alpha=1.75 +- 0.40. Moreover, we show that the effects of rotation on the inner structure of the star may be revealed by asteroseismic observations if frequencies can be determined with a high precision. Existing seismological data of Procyon A are unfortunately not accurate enough to really test these differences in the input physics of our models.

P. Eggenberger; F. Carrier; F. Bouchy

2005-01-14T23:59:59.000Z

208

Water is used for many purposes, includ-ing growing crops, producing copper,  

E-Print Network (OSTI)

WATER USES Water is used for many purposes, includ- ing growing crops, producing copper, generating electricity, watering lawns, keeping clean, drinking and recreation. Bal- ancing the water budget comes down of the water budget. Reducing demand involves re- ducing how much water each person uses, lim- iting the number

209

Office of Legacy Management Buildings Included on EMS Reports...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Office of Legacy Management Buildings Included on EMS Reports Office of Legacy Management Buildings Included on EMS Reports Office of Legacy Management Buildings Included on EMS...

210

Apparatus for conserving energy in a building. [Patent equipment for controlling energy use in unoccupied hotel rooms and other buildings  

SciTech Connect

Apparatus for turning off power-consuming appliances in rooms of a building having a private automatic branch exchange telephone system includes computer-controlled means at the exchange central periodically to apply short bursts of audio-frequency oscillations to telephone lines going to rooms in which power can be conserved. Detecting means in each room connected to the room telephone line provide an output on receipt of a burst which operates a line relay in the room, disconnecting power from the appliance in the room, for a predetermined time period greater than the time period between the periodic application of bursts at the exchange central.

James, E.C.; Fairfax, G.H.

1977-05-03T23:59:59.000Z

211

Percentage of Total Natural Gas Residential Deliveries included...  

Gasoline and Diesel Fuel Update (EIA)

City Gate Price Residential Price Percentage of Total Residential Deliveries included in Prices Commercial Price Percentage of Total Commercial Deliveries included in Prices...

212

Property:Number of Plants included in Capacity Estimate | Open...  

Open Energy Info (EERE)

of Plants included in Capacity Estimate Jump to: navigation, search Property Name Number of Plants included in Capacity Estimate Property Type Number Retrieved from "http:...

213

REDUCTIONS WITHOUT REGRET: DETAILS - AVOIDING BOX CANYONS, ROACH MOTELS, AND WRONG TURNS  

SciTech Connect

The United States is concurrently pursuing the goals of reducing the size of its nuclear weapons force strategic and non-strategic, deployed and non-deployed and of modernizing the weapons it continues to possess. Many of the existing systems were deployed 30 to 50 years ago, and the modernization process can be expected to extend over the next decade or more. Given the impossibility of predicting the future over the lifetime of systems that could extend to the end of this century, it is essential that dead ends in force development be avoided, and the flexibility and availability of options be retained that allow for Scalability downward in the event that further reductions are agreed upon; Reposturing to respond to changes in threat levels and to new nuclear actors; and Breakout response in the event that a competitor significantly increases its force size or force capability, In this paper, we examine the current motivations for reductions and modernization; review a number of historical systems and the attendant capabilities that have been eliminated in recent decades; discuss the current path forward for the U.S. nuclear force; provide a view of the evolving deterrence situation and our assessment of the uncertainties involved; and present examples of possibly problematic directions in force development. We close with our thoughts on how to maintain flexibility and the availability of options for which a need might recur in the future.

Swegle, John A.; Tincher, Douglas J.

2013-08-09T23:59:59.000Z

214

Natural Gas Deliveries to Commercial Consumers (Including Vehicle ...  

U.S. Energy Information Administration (EIA)

Natural Gas Deliveries to Commercial Consumers (Including Vehicle Fuel through 1996) in Wisconsin (Million Cubic Feet)

215

Industrial energy-efficiency-improvement program  

SciTech Connect

Progress made by industry toward attaining the voluntary 1980 energy efficiency improvement targets is reported. The mandatory reporting population has been expanded from ten original industries to include ten additional non-targeted industries and all corporations using over one trillion Btu's annually in any manufacturing industry. The ten most energy intensive industries have been involved in the reporting program since the signing of the Energy Policy and Conservation Act and as industrial energy efficiency improvement overview, based primarily on information from these industries (chemicals and allied products; primary metal industry; petroleum and coal products; stone, clay, and glass products; paper and allied products; food and kindred products; fabricated metal products; transportation equipment; machinery, except electrical; and textile mill products), is presented. Reports from industries, now required to report, are included for rubber and miscellaneous plastics; electrical and electronic equipment; lumber and wood; and tobacco products. Additional data from voluntary submissions are included for American Gas Association; American Hotel and Motel Association; General Telephone and Electronics Corporation; and American Telephone and Telegraph Company. (MCW)

1980-12-01T23:59:59.000Z

216

Energetics of a Symmetric Circulation Including Momentum Constraints  

Science Conference Proceedings (OSTI)

A theory of available potential energy (APE) for symmetric circulations, which includes momentum constraints, is presented. The theory is a generalization of the classical theory of APE, which includes only thermal constraints on the circulation. ...

Sorin Codoban; Theodore G. Shepherd

2003-08-01T23:59:59.000Z

217

Guam Refinery Thermal Cracking/Other (including Gas Oil ...  

U.S. Energy Information Administration (EIA)

Guam Refinery Thermal Cracking/Other (including Gas Oil) Downstream Charge Capacity as of January 1 (Barrels per Stream Day)

218

Scheduling optimization of a real flexible job shop including side ...  

E-Print Network (OSTI)

Aug 19, 2013 ... including side constraints regarding preventive maintenance, fixture availabil- ...... Engineering and Engineering Management, pp. 787791.

219

The Kolkata Paise Hotel Problem  

E-Print Network (OSTI)

For $N$ possible customers or agents and $N$ pricewise identical restaurants, we study the collective dynamical states of choices. Each evening, every agent makes his/her choice based on (a) his/her own past experiences and (b) the past restaurant utilisation records (available to everyone). Moreover, each agent makes his/her choice independent of others. If more than one agent turns up in any particular restaurant, one of them is randomly selected by the restaurant and the rest do not get any dinner that evening. Although the prices are the same for all the restaurants, there is a prevailing opinion across agents about the preference rankings of these restaurants and it is commonly shared by all the $N$ agents. Of the $N^N$ possible states, only $N!$ states are ``socially efficient" or Pareto efficient in the sense that no agent can be made better off without making any other agent worse off. This is achieved when all the agents get their dinners. In the absence of mutual interaction across agents occurance ...

Chakrabarti, Bikas K; Chakrabarti, Anindya-Sundar

2007-01-01T23:59:59.000Z

220

Application Summary HOTEL COMPANY, LLC  

Science Conference Proceedings (OSTI)

... Apprentices were trained in the craft and qualified by examination to become craftsmen. ... Apprentice Programs, Inspection/Audit by the Master ...

Note: This page contains sample records for the topic "include hotels motels" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Airport, Transport & Hotel Information | ORNL  

NLE Websites -- All DOE Office Websites (Extended Search)

Airport Information SHARE Airport Information Information related to the Knoxville Airport is listed below. You can find individual airlines' websites by following the "Airlines"...

222

REWAS 2008: Hotel and Travel  

Science Conference Proceedings (OSTI)

The 40-mile coastline offers warm waters, calm surf and white sandy beaches. Average temperature is 25.5 degrees Celsius (78 degrees Fahrenheit).

223

Fiscal Analysis and Land Use Policy in California: A Case Study of the San Jose Employment Land Conversion Analysis  

E-Print Network (OSTI)

Business License -Hotel Tax -Utility Users Tax -Other -Includes utility users tax, business license tax, hotel tax,utility users tax, the business license tax, and the hotel

Elmer, Vicki; Thorne-Lyman, Abigail; Belzer, Dena

2006-01-01T23:59:59.000Z

224

VHCF-4: Housing Reservations  

Science Conference Proceedings (OSTI)

The Bell Tower Hotel is adjacent to the university campus. Hotel guests receive complimentary parking and continental breakfast. Amenities include use of the...

225

Electric and Hybrid Vehicle Testing  

NLE Websites -- All DOE Office Websites (Extended Search)

results. Generally, hotel loads while on charge in fleet use contributes to lower energy efficiencies. These hotel loads can include heating and cooling vehicle battery...

226

Sunday, June 13, 2010 Arrival and hotel check-in (Shilla Hotel and The Suites Hotel)  

E-Print Network (OSTI)

Midzyzdroje, Island of Wolin, Poland 14 - 18 June 2010 Changing water, energy and biogeochemical cycles) of the Coordinated Energy and Water Cycle Observations Project (CEOP) within the Global Energy and Water Cycle has been on various aspects of regional climate change and its effects on water, energy

227

Percentage of Total Natural Gas Industrial Deliveries included...  

U.S. Energy Information Administration (EIA) Indexed Site

Pipeline and Distribution Use Price City Gate Price Residential Price Percentage of Total Residential Deliveries included in Prices Commercial Price Percentage of Total Commercial...

228

Natural Gas Delivered to Consumers in California (Including ...  

U.S. Energy Information Administration (EIA)

Natural Gas Delivered to Consumers in California (Including Vehicle Fuel) (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec; ...

229

FAQ 23-How much depleted uranium -- including depleted uranium...  

NLE Websites -- All DOE Office Websites (Extended Search)

is stored in the United States? How much depleted uranium -- including depleted uranium hexafluoride -- is stored in the United States? In addition to the depleted uranium stored...

230

Electrical machines and assemblies including a yokeless stator ...  

Wind Energy; Partners (27) Visual Patent Search; Success Stories; News; Events; Electrical machines and assemblies including a yokeless stator with modular lamination ...

231

U.S. Refinery Thermal Cracking, Other (including Gas Oil ...  

U.S. Energy Information Administration (EIA)

U.S. Refinery Thermal Cracking, Other (including Gas Oil) Downstream Charge Capacity as of January 1 (Barrels per Stream Day)

232

[Article 1 of 7: Motivates and Includes the Consumer  

NLE Websites -- All DOE Office Websites (Extended Search)

will be diverse and widespread, including renewables, distributed generation, and energy storage. And they will increase rapidly all along the value chain, from suppliers to...

233

Stocks of Total Crude Oil and Petroleum Products (Including SPR)  

U.S. Energy Information Administration (EIA)

-No Data Reported; --= Not Applicable; NA = Not Available; W = Withheld to avoid disclosure of individual company data. Notes: Stocks include those ...

234

Including Retro-Commissioning in Federal Energy Savings Performance...  

NLE Websites -- All DOE Office Websites (Extended Search)

11.2 Retro-Cx in Federal ESPCs Including Retro-Commissioning In Federal Energy Saving Performance Contracts Retro-commissioning generally reduces operating and maintenance costs,...

235

PLOT: A UNIX PROGRAM FOR INCLUDING GRAPHICS IN DOCUMENTS  

E-Print Network (OSTI)

simple, easy-to-read graphics language designed specificallyPROGRAM FOR INCLUDING GRAPHICS IN DOCUMENTS Pavel Curtismeanings as in the GRAFPAC graphics system. Definl. ~ tions

Curtis, Pavel

2013-01-01T23:59:59.000Z

236

Natural Gas Deliveries to Commercial Consumers (Including Vehicle...  

Gasoline and Diesel Fuel Update (EIA)

Natural Gas Deliveries to Commercial Consumers (Including Vehicle Fuel through 1996) in South Dakota (Million Cubic Feet) Natural Gas Deliveries to Commercial Consumers...

237

Natural Gas Delivered to Consumers in South Dakota (Including...  

Gasoline and Diesel Fuel Update (EIA)

History: Monthly Annual Download Data (XLS File) Natural Gas Delivered to Consumers in South Dakota (Including Vehicle Fuel) (Million Cubic Feet) Natural Gas Delivered to...

238

A look at commercial buildings in 1995: Characteristics, energy consumption, and energy expenditures  

SciTech Connect

The commercial sector consists of business establishments and other organizations that provide services. The sector includes service businesses, such as retail and wholesale stores, hotels and motels, restaurants, and hospitals, as well as a wide range of facilities that would not be considered commercial in a traditional economic sense, such as public schools, correctional institutions, and religious and fraternal organizations. Nearly all energy use in the commercial sector takes place in, or is associated with, the buildings that house these commercial activities. Analysis of the structures, activities, and equipment associated with different types of buildings is the clearest way to evaluate commercial sector energy use. The Commercial Buildings Energy Consumption Survey (CBECS) is a national-level sample survey of commercial buildings and their energy suppliers conducted quadrennially (previously triennially) by the Energy Information Administration (EIA). The target population for the 1995 CBECS consisted of all commercial buildings in the US with more than 1,000 square feet of floorspace. Decision makers, businesses, and other organizations that are concerned with the use of energy--building owners and managers, regulators, legislative bodies and executive agencies at all levels of government, utilities and other energy suppliers--are confronted with a buildings sector that is complex. Data on major characteristics (e.g., type of building, size, year constructed, location) collected from the buildings, along with the amount and types of energy the buildings consume, help answer fundamental questions about the use of energy in commercial buildings.

1998-10-01T23:59:59.000Z

239

Active Desiccant Dehumidification Module Integration with Rooftop Packaged HVAC  

Science Conference Proceedings (OSTI)

This report summarizes a research and development program that produced a stand-alone active desiccant module (ADM) that can be easily integrated with new or existing packaged cooling equipment. The program also produced a fully integrated hybrid system, combining the active desiccant section with a conventional direct expansion air-conditioning unit, that resulted in a compact, low-cost, energy-efficient end product. Based upon the results of this investigation, both systems were determined to be highly viable products for commercialization. Major challenges--including wheel development, compact packaging, regeneration burner development, control optimization, and low-cost design--were all successfully addressed by the final prototypes produced and tested as part of this program. Extensive laboratory testing was completed in the SEMCO laboratory for each of the two ADM system approaches. This testing confirmed the performance of the ADM systems to be attractive compared with that of alternate approaches currently used to precondition outdoor air, where a return air path is not readily available for passive desiccant recovery or where first cost is the primary design criterion. Photographs, schematics, and performance maps are provided for the ADM systems that were developed; and many of the control advantages are discussed. Based upon the positive results of this research and development program, field tests are under way for fully instrumented pilot installations of ADM systems in both a hotel/motel and a restaurant.

Fischer, J

2002-04-17T23:59:59.000Z

240

Commercial equipment loads: End-Use Load and Consumer Assessment Program (ELCAP)  

SciTech Connect

The Office of Energy Resources of the Bonneville Power Administration is generally responsible for the agency's power and conservation resource planning. As associated responsibility which supports a variety of office functions is the analysis of historical trends in and determinants of energy consumption. The Office of Energy Resources' End-Use Research Section operates a comprehensive data collection program to provide pertinent information to support demand-side planning, load forecasting, and demand-side program development and delivery. Part of this on-going program is known as the End-Use Load and Consumer Assessment Program (ELCAP), an effort designed to collect electricity usage data through direct monitoring of end-use loads in buildings. This program is conducted for Bonneville by the Pacific Northwest Laboratory. This report provides detailed information on electricity consumption of miscellaneous equipment from the commercial portion of ELCAP. Miscellaneous equipment includes all commercial end-uses except heating, ventilating, air conditioning, and central lighting systems. Some examples of end-uses covered in this report are office equipment, computers, task lighting, refrigeration, and food preparation. Electricity consumption estimates, in kilowatt-hours per square food per year, are provided for each end-use by building type. The following types of buildings are covered: office, retail, restaurant, grocery, warehouse, school, university, and hotel/motel. 6 refs., 35 figs., 12 tabs.

Pratt, R.G.; Williamson, M.A.; Richman, E.E.; Miller, N.E.

1990-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "include hotels motels" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Solar Energy Education. Reader, Part II. Sun story. [Includes glossary  

DOE Green Energy (OSTI)

Magazine articles which focus on the subject of solar energy are presented. The booklet prepared is the second of a four part series of the Solar Energy Reader. Excerpts from the magazines include the history of solar energy, mythology and tales, and selected poetry on the sun. A glossary of energy related terms is included. (BCS)

Not Available

1981-05-01T23:59:59.000Z

242

Energy Transitions: A Systems Approach Including Marcellus Shale Gas Development  

E-Print Network (OSTI)

Energy Transitions: A Systems Approach Including Marcellus Shale Gas Development A Report: A Systems Approach Including Marcellus Shale Gas Development Executive Summary In the 21st century new we focused on the case of un- conventional natural gas recovery from the Marcellus shale In addition

Walter, M.Todd

243

Energy Transitions: A Systems Approach Including Marcellus Shale Gas Development  

E-Print Network (OSTI)

Energy Transitions: A Systems Approach Including Marcellus Shale Gas Development A Report Transitions: A Systems Approach Including Marcellus Shale Gas Development Executive Summary In the 21st the Marcellus shale In addition to the specific questions identified for the case of Marcellus shale gas in New

Angenent, Lars T.

244

What To Include In The Whistleblower Complaint? | National Nuclear Security  

National Nuclear Security Administration (NNSA)

To Include In The Whistleblower Complaint? | National Nuclear Security To Include In The Whistleblower Complaint? | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog What To Include In The Whistleblower Complaint? Home > About Us > Our Operations > Management and Budget > Whistleblower Program > What To Include In The Whistleblower Complaint? What To Include In The Whistleblower Complaint?

245

U-182: Microsoft Windows Includes Some Invalid Certificates | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

82: Microsoft Windows Includes Some Invalid Certificates 82: Microsoft Windows Includes Some Invalid Certificates U-182: Microsoft Windows Includes Some Invalid Certificates June 4, 2012 - 7:00am Addthis PROBLEM: A vulnerability was reported in Microsoft Windows. A remote user may be able to spoof code signing signatures. PLATFORM: Version(s): XP SP3, 2003 SP2, Vista SP2, 2008 SP2, 7 SP1, 2008 R2 SP1; and prior service packs ABSTRACT: The operating system includes some invalid intermediate certificates. The vulnerability is due to the certificate authorities and not the operating system itself. Reference Links: Security tracker ID 1027114 GENERIC-MAP-NOMATCH Vendor Advisory IMPACT ASSESSMENT: High Discussion: The invalid certificates and their thumbprints are: Microsoft Enforced Licensing Intermediate PCA: 2a 83 e9 02 05 91 a5 5f c6

246

Removal of mineral matter including pyrite from coal  

SciTech Connect

Mineral matter, including pyrite, is removed from coal by treatment of the coal with aqueous alkali at a temperature of about 175.degree. to 350.degree. C, followed by acidification with strong acid.

Reggel, Leslie (Pittsburgh, PA); Raymond, Raphael (Bethel Park, PA); Blaustein, Bernard D. (Pittsburgh, PA)

1976-11-23T23:59:59.000Z

247

Free Energy Efficiency Kit includes CFL light bulbs,  

E-Print Network (OSTI)

Free Energy Efficiency Kit Kit includes CFL light bulbs, spray foam, low-flow shower head, and more i ci e n cy On Thursday, March 31st New River Light & Power will sponsor a seminar that is designed

Rose, Annkatrin

248

Characterizations of Aircraft Icing Environments that Include Supercooled Large Drops  

Science Conference Proceedings (OSTI)

Measurements of aircraft icing environments that include supercooled large drops (SLD) greater than 50 ?m in diameter have been made during 38 research flights. These flights were conducted during the First and Third Canadian Freezing Drizzle ...

Stewart G. Cober; George A. Isaac; J. Walter Strapp

2001-11-01T23:59:59.000Z

249

Including costs of supply chain risk in strategic sourcing decisions  

E-Print Network (OSTI)

Cost evaluations do not always include the costs associated with risks when organizations make strategic sourcing decisions. This research was conducted to establish and quantify the impact of risks and risk-related costs ...

Jain, Avani

2009-01-01T23:59:59.000Z

250

Including Atmospheric Layers in Vegetation and Urban Offline Surface Schemes  

Science Conference Proceedings (OSTI)

A formulation to include prognostic atmospheric layers in offline surface schemes is derived from atmospheric equations. Whereas multilayer schemes developed previously need a complex coupling between atmospheric-model levels and surface-scheme ...

Valry Masson; Yann Seity

2009-07-01T23:59:59.000Z

251

Percentage of Total Natural Gas Commercial Deliveries included in Prices  

Gasoline and Diesel Fuel Update (EIA)

City Gate Price Residential Price Percentage of Total Residential Deliveries included in Prices Commercial Price Percentage of Total Commercial Deliveries included in Prices Industrial Price Percentage of Total Industrial Deliveries included in Prices Electric Power Price Period: Monthly Annual City Gate Price Residential Price Percentage of Total Residential Deliveries included in Prices Commercial Price Percentage of Total Commercial Deliveries included in Prices Industrial Price Percentage of Total Industrial Deliveries included in Prices Electric Power Price Period: Monthly Annual Download Series History Download Series History Definitions, Sources & Notes Definitions, Sources & Notes Show Data By: Data Series Area May-13 Jun-13 Jul-13 Aug-13 Sep-13 Oct-13 View History U.S. 63.3 59.3 57.9 57.0 57.4 61.3 1983-2013 Alabama 71.7 71.0 68.5 68.2 68.4 66.7 1989-2013 Alaska 94.1 91.6 91.1 91.0 92.3 92.6 1989-2013 Arizona 84.0 83.0 81.6 80.3 82.8 82.7 1989-2013 Arkansas 37.8 28.3 28.1 28.6 26.7 28.0 1989-2013

252

Percentage of Total Natural Gas Industrial Deliveries included in Prices  

Gasoline and Diesel Fuel Update (EIA)

City Gate Price Residential Price Percentage of Total Residential Deliveries included in Prices Commercial Price Percentage of Total Commercial Deliveries included in Prices Industrial Price Percentage of Total Industrial Deliveries included in Prices Electric Power Price Period: Monthly Annual City Gate Price Residential Price Percentage of Total Residential Deliveries included in Prices Commercial Price Percentage of Total Commercial Deliveries included in Prices Industrial Price Percentage of Total Industrial Deliveries included in Prices Electric Power Price Period: Monthly Annual Download Series History Download Series History Definitions, Sources & Notes Definitions, Sources & Notes Show Data By: Data Series Area May-13 Jun-13 Jul-13 Aug-13 Sep-13 Oct-13 View History U.S. 16.5 16.3 16.0 16.2 16.6 16.9 2001-2013 Alabama 22.1 21.7 21.6 22.8 22.0 22.7 2001-2013 Alaska 100.0 100.0 100.0 100.0 100.0 100.0 2001-2013 Arizona 13.4 15.7 15.3 13.8 13.7 13.9 2001-2013 Arkansas 1.7 1.4 1.2 1.4 1.3 1.5 2001-2013

253

OPTIMAL PRICING AND PRODUCTION POLICIES OF A MAKE-TO-STOCK SYSTEM WITH FLUCTUATING DEMAND  

E-Print Network (OSTI)

-established strategy in service industries where typical examples include airline, hotel and electric utilities

?rmeci, E. Lerzan

254

Introduction to Small-Scale Photovoltaic Systems (Including RETScreen Case  

Open Energy Info (EERE)

Introduction to Small-Scale Photovoltaic Systems (Including RETScreen Case Introduction to Small-Scale Photovoltaic Systems (Including RETScreen Case Study) (Webinar) Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Introduction to Small-Scale Photovoltaic Systems (Including RETScreen Case Study) (Webinar) Focus Area: Solar Topics: Market Analysis Website: www.leonardo-energy.org/webinar-introduction-small-scale-photovoltaic- Equivalent URI: cleanenergysolutions.org/content/introduction-small-scale-photovoltaic Language: English Policies: Deployment Programs DeploymentPrograms: Project Development This video teaches the viewer about photovoltaic arrays and RETscreen's photovoltaic module, which can be used to project the cost and production of an array. An example case study was

255

projects are valued at approximately $67 million (including $15 million  

NLE Websites -- All DOE Office Websites (Extended Search)

projects are valued at approximately $67 million (including $15 million projects are valued at approximately $67 million (including $15 million in non-Federal cost sharing) over four years. The overall goal of the research is to develop carbon dioxide (CO 2 ) capture and separation technologies that can achieve at least 90 percent CO 2 removal at no more than a 35 percent increase in the cost of electricity. The projects, managed by FE's National Energy Technology Laboratory (NETL), include: (1) Linde, LLC, which will use a post-combustion capture technology incorporating BASF's novel amine-based process at a 1-megawatt electric (MWe) equivalent slipstream pilot plant at the National Carbon Capture Center (NCCC) (DOE contribution: $15 million); (2) Neumann Systems Group, Inc., which will design, construct, and test a patented NeuStreamTM absorber at the Colorado

256

Honda Smart Home to Include Berkeley Lab Ventilation Controller  

NLE Websites -- All DOE Office Websites (Extended Search)

Honda Smart Home to Include Berkeley Lab Ventilation Controller Honda Smart Home to Include Berkeley Lab Ventilation Controller Honda smart home October 2013 October-November Special Focus: Energy Efficiency, Buildings, and the Electric Grid Honda Motor Company Inc is proceeding with plans to build a Smart Home in Davis, California, to demonstrate the latest in renewable energy technologies and energy efficiency. The home is expected to produce more energy than is consumed, demonstrating how the goal of "zero net energy" can be met in the near term future. A ventilation controller developed by researchers at Berkeley Lab's Environmental Energy Technologies Division (EETD) will be included in the smart home. EETD is currently working with the developers of the home control system to integrate its control algorithms.

257

DOE Revises its NEPA Regulations, Including Categorical Exclusions |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Revises its NEPA Regulations, Including Categorical Exclusions Revises its NEPA Regulations, Including Categorical Exclusions DOE Revises its NEPA Regulations, Including Categorical Exclusions September 30, 2011 - 2:30pm Addthis On September 27, 2011, the Department of Energy (DOE) approved revisions to its National Environmental Policy Act (NEPA) regulations, and on September 28th, submitted the revisions to the Federal Register. The final regulations, which become effective 30 days after publication in the Federal Register, are the culmination of a 2-year process to review and update DOE's NEPA implementing procedures. This process involved internal evaluation, public participation, and Council on Environmental Quality (CEQ) review. The revisions are designed to focus Departmental resources on projects with the potential for significant environmental impact, to better

258

Solar Energy Education. Renewable energy: a background text. [Includes glossary  

SciTech Connect

Some of the most common forms of renewable energy are presented in this textbook for students. The topics include solar energy, wind power hydroelectric power, biomass ocean thermal energy, and tidal and geothermal energy. The main emphasis of the text is on the sun and the solar energy that it yields. Discussions on the sun's composition and the relationship between the earth, sun and atmosphere are provided. Insolation, active and passive solar systems, and solar collectors are the subtopics included under solar energy. (BCS)

1985-01-01T23:59:59.000Z

259

Thin film solar cell including a spatially modulated intrinsic layer  

SciTech Connect

One or more thin film solar cells in which the intrinsic layer of substantially amorphous semiconductor alloy material thereof includes at least a first band gap portion and a narrower band gap portion. The band gap of the intrinsic layer is spatially graded through a portion of the bulk thickness, said graded portion including a region removed from the intrinsic layer-dopant layer interfaces. The band gap of the intrinsic layer is always less than the band gap of the doped layers. The gradation of the intrinsic layer is effected such that the open circuit voltage and/or the fill factor of the one or plural solar cell structure is enhanced.

Guha, Subhendu (Troy, MI); Yang, Chi-Chung (Troy, MI); Ovshinsky, Stanford R. (Bloomfield Hills, MI)

1989-03-28T23:59:59.000Z

260

Solar Energy Education. Renewable energy: a background text. [Includes glossary  

DOE Green Energy (OSTI)

Some of the most common forms of renewable energy are presented in this textbook for students. The topics include solar energy, wind power hydroelectric power, biomass ocean thermal energy, and tidal and geothermal energy. The main emphasis of the text is on the sun and the solar energy that it yields. Discussions on the sun's composition and the relationship between the earth, sun and atmosphere are provided. Insolation, active and passive solar systems, and solar collectors are the subtopics included under solar energy. (BCS)

Not Available

1985-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "include hotels motels" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Addressing questions about including environmental effects in the DMSO HLA  

SciTech Connect

The Defense Modeling and Simulation Office (DMSO) is developing a High Level Architecture (HLA) to support the DOD Modeling and Simulation (M and S) community. Many, if not all, of the simulations involve the environment in some fashion. In some applications, the simulation takes place in an acknowledged environment without any environmental functionality being taken into account. The Joint Training Federation Prototype (JTFp) is one of several prototype efforts that have been created to provide a test of the DMSO HLA. In addition to addressing the applicability of the HLA to a training community, the JTFp is also one of two prototype efforts that is explicitly including environmental effects in their simulation effort. These two prototyping efforts are examining the issues associated with the inclusion of the environment in an HLA federation. In deciding whether or not to include an environmental federation in the JTFp effort, a number of questions have been raised about the environment and the HLA. These questions have raised the issue of incompatibility between the environment and the HLA and also shown that there is something unique about including the environment in simulations. The purpose of this White Paper, which was developed with inputs from the National Air and Space [Warfare] Model Program among others, is to address the various questions that have been posed about including environmental effects in an HLA simulation.

Hummel, J.R.

1996-10-01T23:59:59.000Z

262

cDNA encoding a polypeptide including a hevein sequence  

DOE Patents (OSTI)

A cDNA clone (HEV1) encoding hevein was isolated via polymerase chain reaction (PCR) using mixed oligonucleotides corresponding to two regions of hevein as primers and a Hevea brasiliensis latex cDNA library as a template. HEV1 is 1,018 nucleotides long and includes an open reading frame of 204 amino acids.

Raikhel, N.V.; Broekaert, W.F.; Namhai Chua; Kush, A.

1993-02-16T23:59:59.000Z

263

Thermal Unit Commitment Including Optimal AC Power Flow Constraints  

E-Print Network (OSTI)

Thermal Unit Commitment Including Optimal AC Power Flow Constraints Carlos Murillo{Sanchez Robert J algorithm for unit commitment that employs a Lagrange relaxation technique with a new augmentation. This framework allows the possibility of committing units that are required for the VArs that they can produce

264

Major initiatives in materials research at Western include  

E-Print Network (OSTI)

in nuclear reactors; and a third in Engineering- J. Jiang, supported by UNENE, working on control in the theory of condensed matter, including its applications to polymers, optical, electronic, and magnetic NSERC Industrial Research Chairs who together make Western a leading university in nuclear power

Christensen, Dan

265

DOE Considers Natural Gas Utility Service Options: Proposal Includes  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Considers Natural Gas Utility Service Options: Proposal Considers Natural Gas Utility Service Options: Proposal Includes 30-mile Natural Gas Pipeline from Pasco to Hanford DOE Considers Natural Gas Utility Service Options: Proposal Includes 30-mile Natural Gas Pipeline from Pasco to Hanford January 23, 2012 - 12:00pm Addthis Media Contacts Cameron Hardy, DOE , (509) 376-5365, Cameron.Hardy@rl.doe.gov RICHLAND, WASH. - The U.S. Department of Energy (DOE) is considering natural gas transportation and distribution requirements to support the Waste Treatment Plant (WTP) and evaporator operations at the Hanford Site in southeastern Washington State. DOE awarded a task order worth up to $5 million to the local, licensed supplier of natural gas in the Hanford area, Cascade Natural Gas Corporation (Cascade). Cascade will support DOE and its Environmental

266

Italy (including San Marino) Fossil-Fuel CO2 Emissions  

NLE Websites -- All DOE Office Websites (Extended Search)

Western Europe » Italy Western Europe » Italy (including San Marino) Italy (including San Marino) Fossil-Fuel CO2 Emissions Graph graphic Graphics Data graphic Data Trends As occurred in many industrialized nations, CO2 emissions from Italy rose steeply since the late 1940's until the growth was abruptly terminated in 1974. Since 1974, emissions from liquid fuels have vacillated, dropping from 76% to 46% of a static but varying total. Significant increases in natural gas consumption have compensated for the drop in oil consumption. In 2008, 35.8% of Italy's fossil-fuel CO2 emissions were due to natural gas consumption. Coal usage grew steadily until 1985 when CO2 emissions from coal consumption reached 16 million metric tons of carbon. Not until 2004 did coal usage exceed 1985 levels and now accounts for 13.9% of Italy's

267

Coordination). Participants include representatives from Balancing Authorities (BAs), Reliability  

E-Print Network (OSTI)

The MRO Subject Matter Expert Team is an industry stakeholder group which includes subject matter experts from MRO member organizations in various technical areas. Any materials, guidance, and views from stakeholder groups are meant to be helpful to industry participants; but should not be considered approved or endorsed by MRO staff or its board of directors unless specified. Page | 2 Disclaimer The Midwest Reliability Organization (MRO) Standards Committee (SC) is committed to providing training and non-binding guidance to industry stakeholders regarding existing and emerging Reliability Standards. Any materials, including presentations, were developed through the MRO SC by Subject Matter Experts (SMEs) from member organizations within the MRO region. In 2012, SMEs in the field of System Operator Communications were brought together to prepare a guide for complying with NERC Reliability Standard COM-002-2 (Communications and

Will Behnke; Alliant Energy; Jacalynn Bentz; Great River Energy; Marie Knox Miso; Jacalynn Bentz; Marie Knox; Terry Harbour

2013-01-01T23:59:59.000Z

268

Flicker Performance of Modern Lighting Technologies including Impacts of Dimmers  

Science Conference Proceedings (OSTI)

The existing industry standards on flicker measurement and assessment are based on the response of general purpose incandescent lamps. However, worldwide these lamps are being replaced with more energy efficient lamps including Compact Fluorescent Lamps (CFLs) and Light emitting Diode (LED) lamps. In order to keep the flicker standards relevant, the industry standard bodies on the subject are in need of the evidence that compares the flicker performance of new lighting ...

2012-12-12T23:59:59.000Z

269

Conversion of geothermal waste to commercial products including silica  

DOE Patents (OSTI)

A process for the treatment of geothermal residue includes contacting the pigmented amorphous silica-containing component with a depigmenting reagent one or more times to depigment the silica and produce a mixture containing depigmented amorphous silica and depigmenting reagent containing pigment material; separating the depigmented amorphous silica and from the depigmenting reagent to yield depigmented amorphous silica. Before or after the depigmenting contacting, the geothermal residue or depigmented silica can be treated with a metal solubilizing agent to produce another mixture containing pigmented or unpigmented amorphous silica-containing component and a solubilized metal-containing component; separating these components from each other to produce an amorphous silica product substantially devoid of metals and at least partially devoid of pigment. The amorphous silica product can be neutralized and thereafter dried at a temperature from about 25.degree. C. to 300.degree. C. The morphology of the silica product can be varied through the process conditions including sequence contacting steps, pH of depigmenting reagent, neutralization and drying conditions to tailor the amorphous silica for commercial use in products including filler for paint, paper, rubber and polymers, and chromatographic material.

Premuzic, Eugene T. (East Moriches, NY); Lin, Mow S. (Rocky Point, NY)

2003-01-01T23:59:59.000Z

270

Multi-processor including data flow accelerator module  

DOE Patents (OSTI)

An accelerator module for a data flow computer includes an intelligent memory. The module is added to a multiprocessor arrangement and uses a shared tagged memory architecture in the data flow computer. The intelligent memory module assigns locations for holding data values in correspondence with arcs leading to a node in a data dependency graph. Each primitive computation is associated with a corresponding memory cell, including a number of slots for operands needed to execute a primitive computation, a primitive identifying pointer, and linking slots for distributing the result of the cell computation to other cells requiring that result as an operand. Circuitry is provided for utilizing tag bits to determine automatically when all operands required by a processor are available and for scheduling the primitive for execution in a queue. Each memory cell of the module may be associated with any of the primitives, and the particular primitive to be executed by the processor associated with the cell is identified by providing an index, such as the cell number for the primitive, to the primitive lookup table of starting addresses. The module thus serves to perform functions previously performed by a number of sections of data flow architectures and coexists with conventional shared memory therein. A multiprocessing system including the module operates in a hybrid mode, wherein the same processing modules are used to perform some processing in a sequential mode, under immediate control of an operating system, while performing other processing in a data flow mode.

Davidson, George S. (Albuquerque, NM); Pierce, Paul E. (Albuquerque, NM)

1990-01-01T23:59:59.000Z

271

Global Analysis of Solar Neutrino Oscillations Including SNO CC Measurement  

E-Print Network (OSTI)

For active and sterile neutrinos, we present the globally allowed solutions for two neutrino oscillations. We include the SNO CC measurement and all other relevant solar neutrino and reactor data. Five active neutrino oscillation solutions (LMA, LOW, SMA, VAC, and Just So2) are currently allowed at 3 sigma; three sterile neutrino solutions (Just So2, SMA, and VAC) are allowed at 3 sigma. The goodness of fit is satisfactory for all eight solutions. We also investigate the robustness of the allowed solutions by carrying out global analyses with and without: 1) imposing solar model constraints on the 8B neutrino flux, 2) including the Super-Kamiokande spectral energy distribution and day-night data, 3) including a continuous mixture of active and sterile neutrinos, 4) using an enhanced CC cross section for deuterium (due to radiative corrections), and 5) a optimistic, hypothetical reduction by a factor of three of the error of the SNO CC rate. For every analysis strategy used in this paper, the most favored solutions all involve large mixing angles: LMA, LOW, or VAC. The favored solutions are robust, but the presence at 3 sigma of individual sterile solutions and the active Just So2 solution is sensitive to the analysis assumptions.

John N. Bahcall; M. C. Gonzalez-Garcia; Carlos Pena-Garay

2001-06-25T23:59:59.000Z

272

Information regarding previous INCITE awards including selected highlights  

Office of Science (SC) Website

Information regarding previous INCITE awards including selected highlights Advanced Scientific Computing Research (ASCR) ASCR Home About Research Facilities Accessing ASCR Supercomputers Oak Ridge Leadership Computing Facility (OLCF) Argonne Leadership Computing Facility (ALCF) National Energy Research Scientific Computing Center (NERSC) Energy Sciences Network (ESnet) Research & Evaluation Prototypes (REP) Innovative & Novel Computational Impact on Theory and Experiment (INCITE) ASCR Leadership Computing Challenge (ALCC) Science Highlights Benefits of ASCR Funding Opportunities Advanced Scientific Computing Advisory Committee (ASCAC) News & Resources Contact Information Advanced Scientific Computing Research U.S. Department of Energy SC-21/Germantown Building

273

Composite armor, armor system and vehicle including armor system  

DOE Patents (OSTI)

Composite armor panels are disclosed. Each panel comprises a plurality of functional layers comprising at least an outermost layer, an intermediate layer and a base layer. An armor system incorporating armor panels is also disclosed. Armor panels are mounted on carriages movably secured to adjacent rails of a rail system. Each panel may be moved on its associated rail and into partially overlapping relationship with another panel on an adjacent rail for protection against incoming ordnance from various directions. The rail system may be configured as at least a part of a ring, and be disposed about a hatch on a vehicle. Vehicles including an armor system are also disclosed.

Chu, Henry S.; Jones, Warren F.; Lacy, Jeffrey M.; Thinnes, Gary L.

2013-01-01T23:59:59.000Z

274

cDNA encoding a polypeptide including a hevein sequence  

DOE Patents (OSTI)

A cDNA clone (HEV1) encoding hevein was isolated via polymerase chain reaction (PCR) using mixed oligonucleotides corresponding to two regions of hevein as primers and a Hevea brasiliensis latex cDNA library as a template. HEV1 is 1018 nucleotides long and includes an open reading frame of 204 amino acids. The deduced amino acid sequence contains a pu GOVERNMENT RIGHTS This application was funded under Department of Energy Contract DE-AC02-76ER01338. The U.S. Government has certain rights under this application and any patent issuing thereon.

Raikhel, Natasha V. (Okemos, MI); Broekaert, Willem F. (Dilbeek, BE); Chua, Nam-Hai (Scarsdale, NY); Kush, Anil (New York, NY)

1993-02-16T23:59:59.000Z

275

Composite material including nanocrystals and methods of making  

DOE Patents (OSTI)

Temperature-sensing compositions can include an inorganic material, such as a semiconductor nanocrystal. The nanocrystal can be a dependable and accurate indicator of temperature. The intensity of emission of the nanocrystal varies with temperature and can be highly sensitive to surface temperature. The nanocrystals can be processed with a binder to form a matrix, which can be varied by altering the chemical nature of the surface of the nanocrystal. A nanocrystal with a compatibilizing outer layer can be incorporated into a coating formulation and retain its temperature sensitive emissive properties

Bawendi, Moungi G. (Boston, MA); Sundar, Vikram C. (New York, NY)

2008-02-05T23:59:59.000Z

276

Community Assessment Tool for Public Health Emergencies Including Pandemic Influenza  

SciTech Connect

The Community Assessment Tool (CAT) for Public Health Emergencies Including Pandemic Influenza (hereafter referred to as the CAT) was developed as a result of feedback received from several communities. These communities participated in workshops focused on influenza pandemic planning and response. The 2008 through 2011 workshops were sponsored by the Centers for Disease Control and Prevention (CDC). Feedback during those workshops indicated the need for a tool that a community can use to assess its readiness for a disaster - readiness from a total healthcare perspective, not just hospitals, but the whole healthcare system. The CAT intends to do just that - help strengthen existing preparedness plans by allowing the healthcare system and other agencies to work together during an influenza pandemic. It helps reveal each core agency partners (sectors) capabilities and resources, and highlights cases of the same vendors being used for resource supplies (e.g., personal protective equipment [PPE] and oxygen) by the partners (e.g., public health departments, clinics, or hospitals). The CAT also addresses gaps in the community's capabilities or potential shortages in resources. This tool has been reviewed by a variety of key subject matter experts from federal, state, and local agencies and organizations. It also has been piloted with various communities that consist of different population sizes, to include large urban to small rural communities.

ORAU's Oak Ridge Institute for Science Education (HCTT-CHE)

2011-04-14T23:59:59.000Z

277

Community Assessment Tool for Public Health Emergencies Including Pandemic Influenza  

SciTech Connect

The Community Assessment Tool (CAT) for Public Health Emergencies Including Pandemic Influenza (hereafter referred to as the CAT) was developed as a result of feedback received from several communities. These communities participated in workshops focused on influenza pandemic planning and response. The 2008 through 2011 workshops were sponsored by the Centers for Disease Control and Prevention (CDC). Feedback during those workshops indicated the need for a tool that a community can use to assess its readiness for a disaster - readiness from a total healthcare perspective, not just hospitals, but the whole healthcare system. The CAT intends to do just that - help strengthen existing preparedness plans by allowing the healthcare system and other agencies to work together during an influenza pandemic. It helps reveal each core agency partners (sectors) capabilities and resources, and highlights cases of the same vendors being used for resource supplies (e.g., personal protective equipment [PPE] and oxygen) by the partners (e.g., public health departments, clinics, or hospitals). The CAT also addresses gaps in the community's capabilities or potential shortages in resources. This tool has been reviewed by a variety of key subject matter experts from federal, state, and local agencies and organizations. It also has been piloted with various communities that consist of different population sizes, to include large urban to small rural communities.

ORAU' s Oak Ridge Institute for Science Education (HCTT-CHE)

2011-04-14T23:59:59.000Z

278

Property:CBECSSubCategories | Open Energy Information  

Open Energy Info (EERE)

CBECSSubCategories CBECSSubCategories Jump to: navigation, search This is a property of type String. Subproperties This property has the following 1 subproperty: S Service Pages using the property "CBECSSubCategories" Showing 13 pages using this property. E Education + elementary or middle school +, high school +, college or university +, ... F Food Sales + grocery store or food market +, gas station with a convenience store +, convenience store + Food Service + fast food +, restaurant or cafeteria + H Health Care (Inpatient) + hospital +, inpatient rehabilitation + Health Care (Outpatient) + medical office +, clinic or other outpatient health care +, outpatient rehabilitation +, ... L Lodging + motel or inn; hotel; dormitory +, fraternity +, or sorority; retirement home; nursing home +, ...

279

Notices ROUTINE USES OF RECORDS MAINTAINED IN THE SYSTEM, INCLUDING  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

83 Federal Register 83 Federal Register / Vol. 78, No. 51 / Friday, March 15, 2013 / Notices ROUTINE USES OF RECORDS MAINTAINED IN THE SYSTEM, INCLUDING CATEGORIES OF USERS AND THE PURPOSES OF SUCH USES: The Department may disclose information contained in a record in this system of records under the routine uses listed in this system of records without the consent of the individual if the disclosure is compatible with the purposes for which the record was collected. These disclosures may be made on a case-by-case basis or, if the Department has complied with the computer matching requirements of the Privacy Act of 1974, as amended (Privacy Act), under a computer matching agreement. Any disclosure of individually identifiable information from a record in this system must also comply with the requirements of section

280

Copper laser modulator driving assembly including a magnetic compression laser  

DOE Patents (OSTI)

A laser modulator (10) having a low voltage assembly (12) with a plurality of low voltage modules (14) with first stage magnetic compression circuits (20) and magnetic assist inductors (28) with a common core (91), such that timing of the first stage magnetic switches (30b) is thereby synchronized. A bipolar second stage of magnetic compression (42) is coupled to the low voltage modules (14) through a bipolar pulse transformer (36) and a third stage of magnetic compression (44) is directly coupled to the second stage of magnetic compression (42). The low voltage assembly (12) includes pressurized boxes (117) for improving voltage standoff between the primary winding assemblies (34) and secondary winding (40) contained therein.

Cook, Edward G. (Livermore, CA); Birx, Daniel L. (Oakley, CA); Ball, Don G. (Livermore, CA)

1994-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "include hotels motels" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

[Article 1 of 7: Motivates and Includes the Consumer]  

NLE Websites -- All DOE Office Websites (Extended Search)

2 of 7: Research on the Characteristics of a Modern Grid by the NETL 2 of 7: Research on the Characteristics of a Modern Grid by the NETL Modern Grid Strategy Team Accommodates All Generation and Storage Options Last month we presented the first Principal Characteristic of a Modern Grid, "Motivates and Includes the Consumer". This month we present a second characteristic, "Accommodates All Generation and Storage Options". This characteristic will fundamentally transition today's grid from a centralized model for generation to one that also has a more balanced contribution from decentralized generation and storage. This characteristic, along with the other six, define a Modern Grid that will power the 21 st Century economy. For a more detailed discussion on "Accommodates All Generation and Storage Options", please see:

282

Search for Earth-like planets includes LANL star analysis  

NLE Websites -- All DOE Office Websites (Extended Search)

Search for earth-like planets Search for earth-like planets Search for Earth-like planets includes LANL star analysis The mission will not only be able to search for planets around other stars, but also yield new insights into the parent stars themselves. March 6, 2009 Los Alamos National Laboratory sits on top of a once-remote mesa in northern New Mexico with the Jemez mountains as a backdrop to research and innovation covering multi-disciplines from bioscience, sustainable energy sources, to plasma physics and new materials. Los Alamos National Laboratory sits on top of a once-remote mesa in northern New Mexico with the Jemez mountains as a backdrop to research and innovation covering multi-disciplines from bioscience, sustainable energy sources, to plasma physics and new materials.

283

Dye laser amplifier including a specifically designed diffuser assembly  

SciTech Connect

A large (high flow rate) dye laser amplifier in which a continuous replened supply of dye is excited by a first light beam, specifically a copper vapor laser beam, in order to amplify the intensity of a second different light beam, specifically a dye beam, passing through the dye is disclosed herein. This amplifier includes a dye cell defining a dye chamber through which a continuous stream of dye is caused to pass at a relatively high flow rate and a specifically designed diffuser assembly for slowing down the flow of dye while, at the same time, assuring that as the dye stream flows through the diffuser assembly it does so in a stable manner.

Davin, James (Gilroy, CA); Johnston, James P. (Stanford, CA)

1992-01-01T23:59:59.000Z

284

Electra-optical device including a nitrogen containing electrolyte  

DOE Patents (OSTI)

Described is a thin-film battery, especially a thin-film microbattery, and a method for making same having application as a backup or primary integrated power source for electronic devices. The battery includes a novel electrolyte which is electrochemically stable and does not react with the lithium anode and a novel vanadium oxide cathode. Configured as a microbattery, the battery can be fabricated directly onto a semiconductor chip, onto the semiconductor die or onto any portion of the chip carrier. The battery can be fabricated to any specified size or shape to meet the requirements of a particular application. The battery is fabricated of solid state materials and is capable of operation between {minus}15 C and 150 C.

Bates, J.B.; Dudney, N.J.; Gruzalski, G.R.; Luck, C.F.

1995-10-03T23:59:59.000Z

285

Hydraulic engine valve actuation system including independent feedback control  

DOE Patents (OSTI)

A hydraulic valve actuation assembly may include a housing, a piston, a supply control valve, a closing control valve, and an opening control valve. The housing may define a first fluid chamber, a second fluid chamber, and a third fluid chamber. The piston may be axially secured to an engine valve and located within the first, second and third fluid chambers. The supply control valve may control a hydraulic fluid supply to the piston. The closing control valve may be located between the supply control valve and the second fluid chamber and may control fluid flow from the second fluid chamber to the supply control valve. The opening control valve may be located between the supply control valve and the second fluid chamber and may control fluid flow from the supply control valve to the second fluid chamber.

Marriott, Craig D

2013-06-04T23:59:59.000Z

286

A thermovoltaic semiconductor device including a plasma filter  

DOE Patents (OSTI)

A thermovoltaic energy conversion device and related method for converting thermal energy into an electrical potential are disclosed. An interference filter is provided on a semiconductor thermovoltaic cell to pre-filter black body radiation. The semiconductor thermovoltaic cell includes a P/N junction supported on a substrate which converts incident thermal energy below the semiconductor junction band gap into electrical potential. The semiconductor substrate is doped to provide a plasma filter which reflects back energy having a wavelength which is above the band gap and which is ineffectively filtered by the interference filter, through the P/N junction to the source of radiation thereby avoiding parasitic absorption of the unusable portion of the thermal radiation energy.

Baldasaro, Paul F.

1997-12-01T23:59:59.000Z

287

Electra-optical device including a nitrogen containing electrolyte  

SciTech Connect

Described is a thin-film battery, especially a thin-film microbattery, and a method for making same having application as a backup or primary integrated power source for electronic devices. The battery includes a novel electrolyte which is electrochemically stable and does not react with the lithium anode and a novel vanadium oxide cathode Configured as a microbattery, the battery can be fabricated directly onto a semiconductor chip, onto the semiconductor die or onto any portion of the chip carrier. The battery can be fabricated to any specified size or shape to meet the requirements of a particular application. The battery is fabricated of solid state materials and is capable of operation between -15.degree. C. and 150.degree. C.

Bates, John B. (Oak Ridge, TN); Dudney, Nancy J. (Knoxville, TN); Gruzalski, Greg R. (Oak Ridge, TN); Luck, Christopher F. (Knoxville, TN)

1995-01-01T23:59:59.000Z

288

Extractant composition including crown ether and calixarene extractants  

SciTech Connect

An extractant composition comprising a mixed extractant solvent consisting of calix[4] arene-bis-(tert-octylbenzo)-crown-6 ("BOBCalixC6"), 4',4',(5')-di-(t-butyldicyclo-hexano)-18-crown-6 ("DtBu18C6"), and at least one modifier dissolved in a diluent. The DtBu18C6 may be present at from approximately 0.01M to approximately 0.4M, such as at from approximately 0.086 M to approximately 0.108 M. The modifier may be 1-(2,2,3,3-tetrafluoropropoxy)-3-(4-sec-butylphenoxy)-2-propanol ("Cs-7SB") and may be present at from approximately 0.01M to approximately 0.8M. In one embodiment, the mixed extractant solvent includes approximately 0.15M DtBu18C6, approximately 0.007M BOBCalixC6, and approximately 0.75M Cs-7SB modifier dissolved in an isoparaffinic hydrocarbon diluent. The extractant composition further comprises an aqueous phase. The mixed extractant solvent may be used to remove cesium and strontium from the aqueous phase.

Meikrantz, David H. (Idaho Falls, ID); Todd, Terry A. (Aberdeen, ID); Riddle, Catherine L. (Idaho Falls, ID); Law, Jack D. (Pocalello, ID); Peterman, Dean R. (Idaho Falls, ID); Mincher, Bruce J. (Idaho Falls, ID); McGrath, Christopher A. (Blackfoot, ID); Baker, John D. (Blackfoot, ID)

2009-04-28T23:59:59.000Z

289

cDNA encoding a polypeptide including a hevein sequence  

DOE Patents (OSTI)

A cDNA clone (HEV1) encoding hevein was isolated via polymerase chain reaction (PCR) using mixed oligonucleotides corresponding to two regions of hevein as primers and a Hevea brasiliensis latex cDNA library as a template. HEV1 is 1018 nucleotides long and includes an open reading frame of 204 amino acids. The deduced amino acid sequence contains a putative signal sequence of 17 amino acid residues followed by a 187 amino acid polypeptide. The amino-terminal region (43 amino acids) is identical to hevein and shows homology to several chitin-binding proteins and to the amino-termini of wound-induced genes in potato and poplar. The carboxyl-terminal portion of the polypeptide (144 amino acids) is 74--79% homologous to the carboxyl-terminal region of wound-inducible genes of potato. Wounding, as well as application of the plant hormones abscisic acid and ethylene, resulted in accumulation of hevein transcripts in leaves, stems and latex, but not in roots, as shown by using the cDNA as a probe. A fusion protein was produced in E. coli from the protein of the present invention and maltose binding protein produced by the E. coli. 12 figs.

Raikhel, N.V.; Broekaert, W.F.; Chua, N.H.; Kush, A.

1999-05-04T23:59:59.000Z

290

CDNA encoding a polypeptide including a hevein sequence  

DOE Patents (OSTI)

A cDNA clone (HEV1) encoding hevein was isolated via polymerase chain reaction (PCR) using mixed oligonucleotides corresponding to two regions of hevein as primers and a Hevea brasiliensis latex cDNA library as a template. HEV1 is 1018 nucleotides long and includes an open reading frame of 204 amino acids. The deduced amino acid sequence contains a putative signal sequence of 17 amino acid residues followed by a 187 amino acid polypeptide. The amino-terminal region (43 amino acids) is identical to hevein and shows homology to several chitin-binding proteins and to the amino-termini of wound-induced genes in potato and poplar. The carboxyl-terminal portion of the polypeptide (144 amino acids) is 74-79% homologous to the carboxyl-terminal region of wound-inducible genes of potato. Wounding, as well as application of the plant hormones abscisic acid and ethylene, resulted in accumulation of hevein transcripts in leaves, stems and latex, but not in roots, as shown by using the cDNA as a probe. A fusion protein was produced in E. coli from the protein of the present invention and maltose binding protein produced by the E. coli.

Raikhel, Natasha V. (Okemos, MI); Broekaert, Willem F. (Dilbeek, BE); Chua, Nam-Hai (Scarsdale, NY); Kush, Anil (New York, NY)

1995-03-21T23:59:59.000Z

291

cDNA encoding a polypeptide including a hevein sequence  

DOE Patents (OSTI)

A cDNA clone (HEV1) encoding hevein was isolated via polymerase chain reaction (PCR) using mixed oligonucleotides corresponding to two regions of hevein as primers and a Hevea brasiliensis latex cDNA library as a template. HEV1 is 1018 nucleotides long and includes an open reading frame of 204 amino acids. The deduced amino acid sequence contains a putative signal sequence of 17 amino acid residues followed by a 187 amino acid polypeptide. The amino-terminal region (43 amino acids) is identical to hevein and shows homology to several chitin-binding proteins and to the amino-termini of wound-induced genes in potato and poplar. The carboxyl-terminal portion of the polypeptide (144 amino acids) is 74-79% homologous to the carboxyl-terminal region of wound-inducible genes of potato. Wounding, as well as application of the plant hormones abscisic acid and ethylene, resulted in accumulation of hevein transcripts in leaves, stems and latex, but not in roots, as shown by using the cDNA as a probe. A fusion protein was produced in E. coli from the protein of the present invention and maltose binding protein produced by the E. coli.

Raikhel, Natasha V. (Okemos, MI); Broekaert, Willem F. (Dilbeek, BE); Chua, Nam-Hai (Scarsdale, NY); Kush, Anil (New York, NY)

1999-05-04T23:59:59.000Z

292

cDNA encoding a polypeptide including a hevein sequence  

DOE Patents (OSTI)

A cDNA clone (HEV1) encoding hevein was isolated via polymerase chain reaction (PCR) using mixed oligonucleotides corresponding to two regions of hevein as primers and a Hevea brasiliensis latex cDNA library as a template. HEV1 is 1,018 nucleotides long and includes an open reading frame of 204 amino acids. The deduced amino acid sequence contains a putative signal sequence of 17 amino acid residues followed by a 187 amino acid polypeptide. The amino-terminal region (43 amino acids) is identical to hevein and shows homology to several chitin-binding proteins and to the amino-termini of wound-induced genes in potato and poplar. The carboxyl-terminal portion of the polypeptide (144 amino acids) is 74--79% homologous to the carboxyl-terminal region of wound-inducible genes of potato. Wounding, as well as application of the plant hormones abscisic acid and ethylene, resulted in accumulation of hevein transcripts in leaves, stems and latex, but not in roots, as shown by using the cDNA as a probe. A fusion protein was produced in E. coli from the protein of the present invention and maltose binding protein produced by the E. coli. 11 figures.

Raikhel, N.V.; Broekaert, W.F.; Chua, N.H.; Kush, A.

1995-03-21T23:59:59.000Z

293

Analysis of 70 Ophiuchi AB including seismic constraints  

E-Print Network (OSTI)

The analysis of solar-like oscillations for stars belonging to a binary system provides a unique opportunity to probe the internal stellar structure and to test our knowledge of stellar physics. Such oscillations have been recently observed and characterized for the A component of the 70 Ophiuchi system. A model of 70 Ophiuchi AB that correctly reproduces all observational constraints available for both stars is determined. An age of 6.2 +- 1.0 Gyr is found with an initial helium mass fraction Y_i=0.266 +- 0.015 and an initial metallicity (Z/X)_i=0.0300 +- 0.0025 when atomic diffusion is included and a solar value of the mixing-length parameter assumed. A precise and independent determination of the value of the mixing-length parameter needed to model 70 Oph A requires accurate measurement of the mean small separation, which is not available yet. Current asteroseismic observations, however, suggest that the value of the mixing-length parameter of 70 Oph A is lower or equal to the solar calibrated value. The e...

Eggenberger, P; Carrier, F; Fernandes, J; Santos, N C

2008-01-01T23:59:59.000Z

294

Analysis of alpha Centauri AB including seismic constraints  

E-Print Network (OSTI)

Detailed models of alpha Cen A and B based on new seismological data for alpha Cen B by Carrier & Bourban (2003) have been computed using the Geneva evolution code including atomic diffusion. Taking into account the numerous observational constraints now available for the alpha Cen system, we find a stellar model which is in good agreement with the astrometric, photometric, spectroscopic and asteroseismic data. The global parameters of the alpha Cen system are now firmly constrained to an age of t=6.52+-0.30 Gyr, an initial helium mass fraction Y_i=0.275+-0.010 and an initial metallicity (Z/X)_i=0.0434+-0.0020. Thanks to these numerous observational constraints, we confirm that the mixing-length parameter alpha of the B component is larger than the one of the A component, as already suggested by many authors (Noels et al. 1991, Fernandes & Neuforge 1995 and Guenther & Demarque 2000): alpha_B is about 8% larger than alpha_A (alpha_A=1.83+-0.10 and alpha_B=1.97+-0.10). Moreover, we show that asteroseismic measurements enable to determine the radii of both stars with a very high precision (errors smaller than 0.3%). The radii deduced from seismological data are compatible with the new interferometric results of Kervella et al. (2003) even if they are slightly larger than the interferometric radii (differences smaller than 1%).

P. Eggenberger; C. Charbonnel; S. Talon; G. Meynet; A. Maeder; F. Carrier; G. Bourban

2004-01-29T23:59:59.000Z

295

Analysis of 70 Ophiuchi AB including seismic constraints  

E-Print Network (OSTI)

The analysis of solar-like oscillations for stars belonging to a binary system provides a unique opportunity to probe the internal stellar structure and to test our knowledge of stellar physics. Such oscillations have been recently observed and characterized for the A component of the 70 Ophiuchi system. A model of 70 Ophiuchi AB that correctly reproduces all observational constraints available for both stars is determined. An age of 6.2 +- 1.0 Gyr is found with an initial helium mass fraction Y_i=0.266 +- 0.015 and an initial metallicity (Z/X)_i=0.0300 +- 0.0025 when atomic diffusion is included and a solar value of the mixing-length parameter assumed. A precise and independent determination of the value of the mixing-length parameter needed to model 70 Oph A requires accurate measurement of the mean small separation, which is not available yet. Current asteroseismic observations, however, suggest that the value of the mixing-length parameter of 70 Oph A is lower or equal to the solar calibrated value. The effects of atomic diffusion and of the choice of the adopted solar mixture were also studied. We also tested and compared the theoretical tools used for the modeling of stars for which p-modes frequencies are detected by performing this analysis with three different stellar evolution codes and two different calibration methods. We found that the different evolution codes and calibration methods we used led to perfectly coherent results.

P. Eggenberger; A. Miglio; F. Carrier; J. Fernandes; N. C. Santos

2008-02-25T23:59:59.000Z

296

Interim performance criteria for photovoltaic energy systems. [Glossary included  

DOE Green Energy (OSTI)

This document is a response to the Photovoltaic Research, Development, and Demonstration Act of 1978 (P.L. 95-590) which required the generation of performance criteria for photovoltaic energy systems. Since the document is evolutionary and will be updated, the term interim is used. More than 50 experts in the photovoltaic field have contributed in the writing and review of the 179 performance criteria listed in this document. The performance criteria address characteristics of present-day photovoltaic systems that are of interest to manufacturers, government agencies, purchasers, and all others interested in various aspects of photovoltaic system performance and safety. The performance criteria apply to the system as a whole and to its possible subsystems: array, power conditioning, monitor and control, storage, cabling, and power distribution. They are further categorized according to the following performance attributes: electrical, thermal, mechanical/structural, safety, durability/reliability, installation/operation/maintenance, and building/site. Each criterion contains a statement of expected performance (nonprescriptive), a method of evaluation, and a commentary with further information or justification. Over 50 references for background information are also given. A glossary with definitions relevant to photovoltaic systems and a section on test methods are presented in the appendices. Twenty test methods are included to measure performance characteristics of the subsystem elements. These test methods and other parts of the document will be expanded or revised as future experience and needs dictate.

DeBlasio, R.; Forman, S.; Hogan, S.; Nuss, G.; Post, H.; Ross, R.; Schafft, H.

1980-12-01T23:59:59.000Z

297

Community Assessment Tool for Public Health Emergencies Including Pandemic Influenza  

SciTech Connect

The Community Assessment Tool (CAT) for Public Health Emergencies Including Pandemic Influenza (hereafter referred to as the CAT) was developed as a result of feedback received from several communities. These communities participated in workshops focused on influenza pandemic planning and response. The 2008 through 2011 workshops were sponsored by the Centers for Disease Control and Prevention (CDC). Feedback during those workshops indicated the need for a tool that a community can use to assess its readiness for a disasterreadiness from a total healthcare perspective, not just hospitals, but the whole healthcare system. The CAT intends to do just thathelp strengthen existing preparedness plans by allowing the healthcare system and other agencies to work together during an influenza pandemic. It helps reveal each core agency partners' (sectors) capabilities and resources, and highlights cases of the same vendors being used for resource supplies (e.g., personal protective equipment [PPE] and oxygen) by the partners (e.g., public health departments, clinics, or hospitals). The CAT also addresses gaps in the community's capabilities or potential shortages in resources. While the purpose of the CAT is to further prepare the community for an influenza pandemic, its framework is an extension of the traditional all-hazards approach to planning and preparedness. As such, the information gathered by the tool is useful in preparation for most widespread public health emergencies. This tool is primarily intended for use by those involved in healthcare emergency preparedness (e.g., community planners, community disaster preparedness coordinators, 9-1-1 directors, hospital emergency preparedness coordinators). It is divided into sections based on the core agency partners, which may be involved in the community's influenza pandemic influenza response.

HCTT-CHE

2011-04-14T23:59:59.000Z

298

Community Assessment Tool for Public Health Emergencies Including Pandemic Influenza  

SciTech Connect

The Community Assessment Tool (CAT) for Public Health Emergencies Including Pandemic Influenza (hereafter referred to as the CAT) was developed as a result of feedback received from several communities. These communities participated in workshops focused on influenza pandemic planning and response. The 2008 through 2011 workshops were sponsored by the Centers for Disease Control and Prevention (CDC). Feedback during those workshops indicated the need for a tool that a community can use to assess its readiness for a disasterreadiness from a total healthcare perspective, not just hospitals, but the whole healthcare system. The CAT intends to do just thathelp strengthen existing preparedness plans by allowing the healthcare system and other agencies to work together during an influenza pandemic. It helps reveal each core agency partners' (sectors) capabilities and resources, and highlights cases of the same vendors being used for resource supplies (e.g., personal protective equipment [PPE] and oxygen) by the partners (e.g., public health departments, clinics, or hospitals). The CAT also addresses gaps in the community's capabilities or potential shortages in resources. While the purpose of the CAT is to further prepare the community for an influenza pandemic, its framework is an extension of the traditional all-hazards approach to planning and preparedness. As such, the information gathered by the tool is useful in preparation for most widespread public health emergencies. This tool is primarily intended for use by those involved in healthcare emergency preparedness (e.g., community planners, community disaster preparedness coordinators, 9-1-1 directors, hospital emergency preparedness coordinators). It is divided into sections based on the core agency partners, which may be involved in the community's influenza pandemic influenza response.

HCTT-CHE

2011-04-14T23:59:59.000Z

299

P r o f i t P l u s P l a n e t . c o mP r o f i t P l u s P l a n e t . c o m Marriott International's "Spirit to Preserve"  

E-Print Network (OSTI)

Conference March 14-15, 2012 The Energy, Coast & Environment Building Louisiana State University Baton Rouge pay- ment. Hotel Accommodations Please make lodging arrangements directly with the hotel of your choice. Suggested hotels include: Staybridge Suites The Cook Hotel Courtyard by Marriott La Quinta

Loudon, Catherine

300

LBNL-57978 ERNEST ORLANDO LAWRENCE  

E-Print Network (OSTI)

=Laguerre-Gauss Hotelling) Figure 7. The logarithm of the optimal fluence ( 2 m- ) vs. energy using Hotelling observer) methodology. Hotelling and Laguerre­Gauss Hotelling observers are used to perform various lesion detection tasks. Several model observer tasks were used including SKE/BKE, MAFC and SKEV. The energy levels

Note: This page contains sample records for the topic "include hotels motels" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Sailing into the Mainstream of Energy and Water Efficiency, Affordably |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Sailing into the Mainstream of Energy and Water Efficiency, Sailing into the Mainstream of Energy and Water Efficiency, Affordably Sailing into the Mainstream of Energy and Water Efficiency, Affordably October 13, 2010 - 11:50am Addthis John Lippert I took off work on Friday, September 10, to have a 3-day weekend with my wife visiting a research center in Virginia Beach. After consulting Virginia's green lodging Web site, my wife and I jotted down nearly a dozen participating hotels, motels, and bed and breakfasts not far from the research center. We checked rates and availability and were surprised to find many of the hotels with no vacancies. Little did we know that Virginia Beach was observing September 11th with a parade, and a lot of people were in town. Fortunately, the one place both my wife and I liked had

302

ARM: Surface Radiation Measurement Quality Control testing, including climatologically configurable limits  

DOE Data Explorer (OSTI)

Surface Radiation Measurement Quality Control testing, including climatologically configurable limits

Gary Hodges; Tom Stoffel; Mark Kutchenreiter; Bev Kay; Aron Habte; Michael Ritsche; Victor Morris; Mary Anderberg

303

Data:84c1eb82-beb9-4bca-9275-2994a8c66b2e | Open Energy Information  

Open Energy Info (EERE)

eb82-beb9-4bca-9275-2994a8c66b2e eb82-beb9-4bca-9275-2994a8c66b2e No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: South Central Power Company Effective date: 2012/04/01 End date if known: Rate name: Schedule GS General Service Sector: Description: This South Central Power Company (Cooperative) rate schedule is available and applicable for all single and three phase electric service for all uses not specified in Cooperative's residential rate schedules, including, but not limited to, electric service furnished to retail or wholesale businesses, manufacturing or processing establishments, hotels, mobile home or trailer camps, motels, stores, restaurants, service stations, warehouses, medical facilities, athletic facilities, professional offices, theaters, amusement establishments, business offices, schools, churches, clubs, lodges, multiple dwelling units, apartment houses, public buildings, and for all other electric service that is not exclusively for residential, home or farm use. This schedule is applicable for all three phase service whether or not for residential, home or farm use. This schedule may be limited to a maximum billing capacity of 100 kilowatts (kW). All service under schedule "GS" is subject to the provisions of the Cooperative's application form, the provisions of this schedule as well as the Cooperative's Policy Manual and Practices and Procedures Manual (Rules and Regulations) or subsequent revisions thereof, which Rules and Regulations are a part of this schedule as if fully set forth herein.

304

Julian Szekely Memorial Symposium: Royal Sonesta Hotel  

Science Conference Proceedings (OSTI)

... easy access to the historic waterfront, Quincy Market and the financial district. ... If you need any additional information on location directions, please contact...

305

Extended-stay hotel as home.  

E-Print Network (OSTI)

??Housing plays an important interpersonal and sociopolitical role in American culture. Perceptions of personal achievement and life satisfaction in adulthood are often determined by the (more)

Lewinson, Terri Wingate

2007-01-01T23:59:59.000Z

306

Muon Collider Collaboration Meeting Hotel Information  

NLE Websites -- All DOE Office Websites (Extended Search)

meeting will take place at the Hampton Inn in Orange Beach, AL. This is located on the Gulf of Mexico and is a beachfront resort style setting. The room rate will be 70 per day...

307

ENERGY STAR Success Story: Loews Hotels  

NLE Websites -- All DOE Office Websites (Extended Search)

variable frequency drives on large motors across all 18 facilities 30% reduction in motor electric load Installed capacitors on large pumps, motors, and air handler units in...

308

Federal Register/Vol. 69, No. 178/Wednesday, September 15 ...  

Science Conference Proceedings (OSTI)

... Information about the meeting location and hotel accommodations will be ... including whether the information shall have practical utility; (b) the ...

2013-05-10T23:59:59.000Z

309

DOE Order 440. 1 B: Worker Protection Program for DOE (Including...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

0. 1 B: Worker Protection Program for DOE (Including NNSA) Federal Employees DOE Order 440. 1 B: Worker Protection Program for DOE (Including NNSA) Federal Employees Stakeholders:...

310

Composite materials and bodies including silicon carbide and titanium diboride and methods of forming same  

DOE Patents (OSTI)

Methods of forming composite materials include coating particles of titanium dioxide with a substance including boron (e.g., boron carbide) and a substance including carbon, and reacting the titanium dioxide with the substance including boron and the substance including carbon to form titanium diboride. The methods may be used to form ceramic composite bodies and materials, such as, for example, a ceramic composite body or material including silicon carbide and titanium diboride. Such bodies and materials may be used as armor bodies and armor materials. Such methods may include forming a green body and sintering the green body to a desirable final density. Green bodies formed in accordance with such methods may include particles comprising titanium dioxide and a coating at least partially covering exterior surfaces thereof, the coating comprising a substance including boron (e.g., boron carbide) and a substance including carbon.

Lillo, Thomas M.; Chu, Henry S.; Harrison, William M.; Bailey, Derek

2013-01-22T23:59:59.000Z

311

Copper 99/Cobre 99: Industrial Tours  

Science Conference Proceedings (OSTI)

The cost of the hotel and dinner are included in the price of the tour. Day 2: Continental Breakfast is provided. Check-out from the hotel and depart at 8:00 a.m....

312

DOT Motor-fuel use statistics summary to 1995 The data included...  

Open Energy Info (EERE)

Motor-fuel use statistics summary to 1995 The data included in this submission is United States Department of Transportation (DOT) data up to 1995. The data includes motor-fuel...

313

Molecular Dynamics Model of Ultraviolet Matrix-Assisted Laser Desorption/Ionization Including Ionization Processes  

E-Print Network (OSTI)

Molecular Dynamics Model of Ultraviolet Matrix-Assisted Laser Desorption/Ionization Including A molecular dynamics model of UV-MALDI including ionization processes is presented. In addition/desorption of molecular systems, it includes radiative and nonradiative decay, exciton hopping, two pooling processes

Zhigilei, Leonid V.

314

Photovoltaic Device Including A Boron Doping Profile In An I-Type Layer  

DOE Patents (OSTI)

A photovoltaic cell for use in a single junction or multijunction photovoltaic device, which includes a p-type layer of a semiconductor compound including silicon, an i-type layer of an amorphous semiconductor compound including silicon, and an n-type layer of a semiconductor compound including silicon formed on the i-type layer. The i-type layer including an undoped first sublayer formed on the p-type layer, and a boron-doped second sublayer formed on the first sublayer.

Yang, Liyou (Lawrenceville, NJ)

1993-10-26T23:59:59.000Z

315

DOE Order 440. 1 B: Worker Protection Program for DOE (Including NNSA)  

NLE Websites -- All DOE Office Websites (Extended Search)

0. 1 B: Worker Protection Program for DOE (Including 0. 1 B: Worker Protection Program for DOE (Including NNSA) Federal Employees DOE Order 440. 1 B: Worker Protection Program for DOE (Including NNSA) Federal Employees Stakeholders: DOE and NNSA employees Scope: DOE Order 440.1 B establishes the framework for an effective worker protection program that will reduce or prevent injuries, illnesses, and accidental losses by providing Department of Energy, including National Nuclear Security Administration (NNSA), Federal workers with a safe and healthful workplace. Summary: Among the requirements of DOE Order 440.1 B, the Department must provide its employees, including NNSA, a number of protections relating to whistle blowing guidelines. The relevant section of requirements includes: 4. REQUIREMENTS. DOE elements must:

316

Photovoltaic module kit including connector assembly for non-penetrating array installation  

Science Conference Proceedings (OSTI)

A PV module kit for non-penetrating rooftop installation, including a plurality of PV modules and a plurality of connectors. Each of the PV modules includes a PV laminate and a frame forming a mounting region assembled thereto. The connectors include a male connector having a male fastener extending from a head, and a female connector having a female fastener assembled within a head. The heads are entirely formed of plastic. The kit provides a mounted array state including a junction at which the mounting region of at least two of the PV modules are aligned and interconnected by engagement of the male connector with the female connector. The so-formed junction is substantially electrically insulated. The plurality of connectors can further include a spacer connector including a head forming a bore sized to slidably receive the male fastener, with all of the connector heads being identical.

Botkin, Jonathan (El Cerrito, CA); Graves, Simon (Berkeley, CA); Danning, Matt (Oakland, CA); Culligan, Matthew (Berkeley, CA)

2011-11-22T23:59:59.000Z

317

Photovoltaic module kit including connector assembly for non-penetrating array installation  

DOE Patents (OSTI)

A PV module kit for non-penetrating rooftop installation, including a plurality of PV modules and a plurality of connectors. Each of the PV modules includes a PV laminate and a frame forming a mounting region assembled thereto. The connectors include a male connector having a male fastener extending from a head, and a female connector having a female fastener assembled within a head. The heads are entirely formed of plastic. The kit provides a mounted array state including a junction at which the mounting region of at least two of the PV modules are aligned and interconnected by engagement of the male connector with the female connector. The so-formed junction is substantially electrically insulated. The plurality of connectors can further include a spacer connector including a head forming a bore sized to slidably receive the male fastener, with all of the connector heads being identical.

Botkin, Jonathan; Graves, Simon; Danning, Matt; Culligan, Matthew

2012-10-23T23:59:59.000Z

318

NREL/Ventyx Utility Rates: What is included? | OpenEI Community  

Open Energy Info (EERE)

NREL/Ventyx Utility Rates: What is included? NREL/Ventyx Utility Rates: What is included? Home > Groups > Utility Rate Does anyone know what pieces of electric rates are included in the NREL/Ventyx database of rates by utility, i.e. is it supply only or does the file include supply, transmission & distribution costs? Thanks! Submitted by Vbugnion on 27 February, 2013 - 16:25 1 answer Points: 1 Hi Vbugnion, Just to clarify, you're not asking about the OpenEI utility rates, but rather the Ventyx rates found here: http://developer.nrel.gov/doc/api/georeserv/service/utility_rates If so, then the Ventyx rates do include all bundled rates (which includes supply, trans, and distr costs). However, there's a small but non-zero possibility that a few energy-only or delivery-only rates may not have been cleaned

319

Multi-objective design and optimization of district energy systems including polygeneration energy conversion technologies.  

E-Print Network (OSTI)

??In the present context of finding ways to decrease CO2 emissions linked with human activity, district energy systems including polygeneration energy conversion technologies are likely (more)

Weber, Cline Isabelle

2008-01-01T23:59:59.000Z

320

Stocks of Crude Oil (Including SPR) - U.S. Energy Information ...  

U.S. Energy Information Administration (EIA)

-No Data Reported; --= Not Applicable; NA = Not Available; W = Withheld to avoid disclosure of individual company data. Notes: Stocks include those ...

Note: This page contains sample records for the topic "include hotels motels" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Petroleum Gasoline & Distillate Needs Including the Energy Independence and Security Act (EISA) Impacts  

Reports and Publications (EIA)

This presentation describes the projections for petroleum-based gasoline and distillate in the Update AEO 2008, which includes the impacts of the Energy Independence and Security Act.

Information Center

2008-03-11T23:59:59.000Z

322

ORISE: REAC/TS Symposium to include sessions on the Fukushima...  

NLE Websites -- All DOE Office Websites (Extended Search)

MEDIA ADVISORY: REACTS International Symposium to include sessions on the Fukushima crisis FOR IMMEDIATE RELEASE Aug. 31, 2011 FY11-42 Who: Radiation Emergency Assistance Center...

323

Comparative chloroplast genomics: Analyses including new sequences from the angiosperms Nuphar advena and Ranunculus macranthus  

E-Print Network (OSTI)

to other angiosperms. BMC Genomics 2006, 7:61. 20.history of chloroplast genomics. Photosynth Res 2003, 76:Comparative chloroplast genomics: Analyses including new

2007-01-01T23:59:59.000Z

324

T-603: Mac OS X Includes Some Invalid Comodo Certificates | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

03: Mac OS X Includes Some Invalid Comodo Certificates 03: Mac OS X Includes Some Invalid Comodo Certificates T-603: Mac OS X Includes Some Invalid Comodo Certificates April 15, 2011 - 1:46am Addthis PROBLEM: Mac OS X Includes Some Invalid Comodo Certificates PLATFORM: For Mac OS X Server v10.5.8, Mac OS X v10.5.8, Mac OS X v10.6.7 and Mac OS X Server v10.6.7 ABSTRACT: The operating system includes some invalid certificates. The vulnerability is due to the invalid certificates and not the operating system itself. Other browsers, applications, and operating systems are affected. reference LINKS: SecurityTracker Alert ID: 1025362 APPLE-SA-2011-04-14-4 Security Update 2011-002 Apple Support Downloads IMPACT ASSESSMENT: High Discussion: A partner of Comodo with Registration Authority capabilities suffered an internal security breach and the attacker caused seven certificates to be

325

Property:Number of Plants Included in Planned Estimate | Open Energy  

Open Energy Info (EERE)

Plants Included in Planned Estimate Plants Included in Planned Estimate Jump to: navigation, search Property Name Number of Plants Included in Planned Estimate Property Type String Description Number of plants included in the estimate of planned capacity per GEA Pages using the property "Number of Plants Included in Planned Estimate" Showing 21 pages using this property. A Alaska Geothermal Region + 3 + C Cascades Geothermal Region + 1 + Central Nevada Seismic Zone Geothermal Region + 4 + G Gulf of California Rift Zone Geothermal Region + 7 + H Hawaii Geothermal Region + 1 + Holocene Magmatic Geothermal Region + 4 + I Idaho Batholith Geothermal Region + 1 + N Northern Basin and Range Geothermal Region + 9 + Northern Rockies Geothermal Region + 0 + Northwest Basin and Range Geothermal Region + 6 +

326

Systems including catalysts in porous zeolite materials within a reactor for use in synthesizing hydrocarbons  

Science Conference Proceedings (OSTI)

Catalytic structures include a catalytic material disposed within a zeolite material. The catalytic material may be capable of catalyzing a formation of methanol from carbon monoxide and/or carbon dioxide, and the zeolite material may be capable of catalyzing a formation of hydrocarbon molecules from methanol. The catalytic material may include copper and zinc oxide. The zeolite material may include a first plurality of pores substantially defined by a crystal structure of the zeolite material and a second plurality of pores dispersed throughout the zeolite material. Systems for synthesizing hydrocarbon molecules also include catalytic structures. Methods for synthesizing hydrocarbon molecules include contacting hydrogen and at least one of carbon monoxide and carbon dioxide with such catalytic structures. Catalytic structures are fabricated by forming a zeolite material at least partially around a template structure, removing the template structure, and introducing a catalytic material into the zeolite material.

Rolllins, Harry W. (Idaho Falls, ID); Petkovic, Lucia M. (Idaho Falls, ID); Ginosar, Daniel M. (Idaho Falls, ID)

2012-07-24T23:59:59.000Z

327

Systems and strippable coatings for decontaminating structures that include porous material  

SciTech Connect

Methods of removing contaminant matter from porous materials include applying a polymer material to a contaminated surface, irradiating the contaminated surface to cause redistribution of contaminant matter, and removing at least a portion of the polymer material from the surface. Systems for decontaminating a contaminated structure comprising porous material include a radiation device configured to emit electromagnetic radiation toward a surface of a structure, and at least one spray device configured to apply a capture material onto the surface of the structure. Polymer materials that can be used in such methods and systems include polyphosphazine-based polymer materials having polyphosphazine backbone segments and side chain groups that include selected functional groups. The selected functional groups may include iminos, oximes, carboxylates, sulfonates, .beta.-diketones, phosphine sulfides, phosphates, phosphites, phosphonates, phosphinates, phosphine oxides, monothio phosphinic acids, and dithio phosphinic acids.

Fox, Robert V. (Idaho Falls, ID); Avci, Recep (Bozeman, MT); Groenewold, Gary S. (Idaho Falls, ID)

2011-12-06T23:59:59.000Z

328

Revenue Management in a Dynamic Network Environment  

E-Print Network (OSTI)

. Typical applications include sequential reservations for an airline network, hotel, or car rental service an airline (hotel, car rental) net- work composed of l legs (pairs of consecutive days for hotels, car : Rj is the fare category of class j, which utilizes aij units of resource (leg) i. In this way, 0041

Bertsimas, Dimitris

329

Workshop on HITRAP/CaveA Atomic Physics Experiments GSI, Nov 20-21, 2006  

E-Print Network (OSTI)

COMMENTS FROM CUSTOMERS STAYING AT THE HOTEL. The Motion Sensor Nightlight helps save energy and provides bathrooms. Key next steps include: · Educate hotel and institutional owners/managers about energyTypically, hotel bathroom lights are left on between five to eight hours per occupied day

Rumolo, Giovanni

330

Energy Department Expands Gas Gouging Reporting System to Include 1-800  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Expands Gas Gouging Reporting System to Include Expands Gas Gouging Reporting System to Include 1-800 Number: 1-800-244-3301 Energy Department Expands Gas Gouging Reporting System to Include 1-800 Number: 1-800-244-3301 September 6, 2005 - 9:50am Addthis Washington, DC - Energy Secretary Samuel W. Bodman announced today that the Department of Energy has expanded its gas gouging reporting system to include a toll-free telephone hotline. The hotline is available to American consumers starting today. "While we've largely seen the best of American generosity and unity throughout the recovery effort, we recognize that there are some bad actors that may try to take advantage of the situation. Consumers are our first line of defense in guarding against gas price gouging. I can assure you, our Administration - from the President down - takes this issue very

331

RECOMMENDATIONS TO INCLUDE IN CALIFORNIA ENERGY COMMISSION'S 2009 INTEGRATED ENERGY POLICY REPORT (IEPR)  

E-Print Network (OSTI)

RECOMMENDATIONS TO INCLUDE IN CALIFORNIA ENERGY COMMISSION'S 2009 INTEGRATED ENERGY POLICY REPORT solutions. Overview Past Energy Commission Integrated Energy Policy Reports (IEPRs) have recognized (IEPR) Submitted By: Steven Weissman Associate Director Center for Law, Energy and the Environment

Kammen, Daniel M.

332

On a Three Step Model of Anaerobic Digestion Including the Hydrolysis of  

E-Print Network (OSTI)

On a Three Step Model of Anaerobic Digestion Including the Hydrolysis of Particulate Matter R degradation, chemostat, models, growth rate, equilibrium, bistability. 1. INTRODUCTION Anaerobic digestion, the anaerobic digestion is generally considered as a three step process: hydrolysis and liquefaction

Paris-Sud XI, Université de

333

Numerical simulation of ECRIPAC plasma behaviour with Vlasov equations including electron and ion collective effects  

E-Print Network (OSTI)

976 Numerical simulation of ECRIPAC plasma behaviour with Vlasov equations including electron of 4 MeV energy with very short pulses. (`ompared to ISlectron Ring Accelerators, ECRIPAC presents

Paris-Sud XI, Université de

334

Automated solar collector installation design including ability to define heterogeneous design preferences  

DOE Patents (OSTI)

Embodiments may include systems and methods to create and edit a representation of a worksite, to create various data objects, to classify such objects as various types of pre-defined "features" with attendant properties and layout constraints. As part of or in addition to classification, an embodiment may include systems and methods to create, associate, and edit intrinsic and extrinsic properties to these objects. A design engine may apply of design rules to the features described above to generate one or more solar collectors installation design alternatives, including generation of on-screen and/or paper representations of the physical layout or arrangement of the one or more design alternatives. Embodiments may also include definition of one or more design apertures, each of which may correspond to boundaries in which solar collector layouts should comply with distinct sets of user-defined design preferences. Distinct apertures may provide heterogeneous regions of collector layout according to the user-defined design preferences.

Wayne, Gary; Frumkin, Alexander; Zaydman, Michael; Lehman, Scott; Brenner, Jules

2013-01-08T23:59:59.000Z

335

Code Thrust 1400 Aeronautical/Astronautical Engineering (including Aerodynamics, Aerospace Engineering, and Space Technology)  

E-Print Network (OSTI)

Sciences (including Clinical/Medical Laboratory Technologies, Communication Disorders Sciences and Services, Gerontology, Health and Medical Administrative Services, Other Health Professions and Related Services, Environmental health, Geotechnical, Hydraulic, Hydrologic, Sanitary, Structural, and Transportation) 1404

Alabama in Huntsville, University of

336

Light reflecting apparatus including a multi-aberration light reflecting surface  

DOE Patents (OSTI)

A light reflecting apparatus including a multi-aberration bendable light reflecting surface is disclosed herein. This apparatus includes a structural assembly comprised of a rectangular plate which is resiliently bendable, to a limited extent, and which has a front side defining the multi-aberration light reflecting surface and an opposite back side, and a plurality of straight leg members rigidly connected with the back side of the plate and extending rearwardly therefrom. The apparatus also includes a number of different adjustment mechanisms, each of which is connected with specific ones of the leg members. These mechanisms are adjustably movable in different ways for applying corresponding forces to the leg members in order to bend the rectangular plate and light reflecting surface into different predetermined curvatures and which specifically include quadratic and cubic curvatures corresponding to different optical aberrations.

Sawicki, Richard H. (Pleasanton, CA); Sweatt, William (Livermore, CA)

1987-01-01T23:59:59.000Z

337

Modification of the Khler Equation to Include Soluble Trace Gases and Slightly Soluble Substances  

Science Conference Proceedings (OSTI)

A generalized reformulation of the Khler theory to include the effect of soluble gases and slightly soluble aerosol substances is presented. A single equation is derived that takes into account 1) the Kelvin effect; 2) the Raoult effect caused ...

Ari Laaksonen; Pekka Korhonen; Markku Kulmala; Robert J. Charlson

1998-03-01T23:59:59.000Z

338

A New Bulk Microphysical Scheme That Includes Riming Intensity and Temperature-Dependent Ice Characteristics  

Science Conference Proceedings (OSTI)

A new bulk microphysical parameterization (BMP) scheme is presented that includes a diagnosed riming intensity and its impact on ice characteristics. As a result, the new scheme represents a continuous spectrum from pristine ice particles to ...

Yanluan Lin; Brian A. Colle

2011-03-01T23:59:59.000Z

339

Modeling and Controller Design of a Wind Energy Conversion System Including a Matrix Converter.  

E-Print Network (OSTI)

??In this thesis, a grid-connected wind-energy converter system including a matrix converter is proposed. The matrix converter, as a power electronic converter, is used to (more)

Barakati, Seyed Masoud

2008-01-01T23:59:59.000Z

340

Including Surface Kinetic Effects in Simple Models of Ice Vapor Diffusion  

Science Conference Proceedings (OSTI)

A model for kinetically-limited vapor growth and aspect ratio evolution of atmospheric single ice crystals is presented. The method is based on the adaptive habit model of Chen and Lamb (1994), but is modified to include the deposition ...

Chengzhu Zhang; Jerry Y. Harrington

Note: This page contains sample records for the topic "include hotels motels" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

A Simple Model of Abyssal Circulation, Including Effects of Wind, Buoyancy and Topography  

Science Conference Proceedings (OSTI)

We examine problems of steady abyssal circulation using an inviscid planetary geostrophic layered model. The model includes an active wind-driven upper layer and arbitrary topography; forcing is in the form of specified interlayer mass fluxes ...

Susan L. Hautala; Stephen C. Riser

1989-05-01T23:59:59.000Z

342

Options for Removing Multiple Pollutants Including CO2 at Existing Coal-Fired Power Plants  

Science Conference Proceedings (OSTI)

This report is a technical review of the fuel changes and technology options for existing coal-fired power plants in response to potential new requirements for increasingly stringent multi-pollutant air emissions reductions, possibly including carbon dioxide (CO2). Preliminary costing of the major options is included. A database of the U.S. coal-fired power plants has been developed for further, more specific analyses.

2002-10-08T23:59:59.000Z

343

Data:83ff69ef-5cb9-4f94-86e3-42484a519dfd | Open Energy Information  

Open Energy Info (EERE)

ff69ef-5cb9-4f94-86e3-42484a519dfd ff69ef-5cb9-4f94-86e3-42484a519dfd No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Town of Merrimac, Massachusetts (Utility Company) Effective date: 2009/01/01 End date if known: Rate name: RATE C- RESIDENTIAL TOTAL ELECTRIC RATE Sector: Residential Description: Additional Info: Availability: All individual residence/apartment, motels/hotels, apartment houses and similar installations. Additionally, also applicable to Church or school. Given that electricity must be the only source of energy, all electric will be measured by a single meter and all space heating equipment must be permanently installed.

344

Federal Water Use Indices | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Federal Water Use Indices Federal Water Use Indices Federal Water Use Indices FEMP provides water use indices as a guide for Federal agencies. Note that each is a rough estimate of water usage at different types of sites. Your site may vary considerably. The following indices should be used only to assist in determining baseline data when no other information is available on site water usage. Conversion factors for the Federal water use indices are also available. Source: American Water Works Association 1996. Data represents gallons per unit per day. Commercial User Unit Range Typical Airport Passenger 4-5 3 Apartment house Person 100-200 100 Boarding house Person 25-50 40 Hotel Guest 40-60 50 Employee 8-13 10 Lodging house and tourist home Guest 30-50 40 Motel Guest 25-40 35

345

Residential Buildings  

U.S. Energy Information Administration (EIA) Indexed Site

Residential Residential Residential Buildings Residential buildings-such as single family homes, townhomes, condominiums, and apartment buildings-are all covered by the Residential Energy Consumption Survey (RECS). See the RECS home page for further information. However, buildings that offer multiple accomodations such as hotels, motels, inns, dormitories, fraternities, sororities, convents, monasteries, and nursing homes, residential care facilities are considered commercial buildings and are categorized in the CBECS as lodging. Specific questions may be directed to: Joelle Michaels joelle.michaels@eia.doe.gov CBECS Manager Release date: January 21, 2003 Page last modified: May 5, 2009 10:18 AM http://www.eia.gov/consumption/commercial/data/archive/cbecs/pba99/residential.html

346

SLAC Linac Coherent Light Source User Site  

NLE Websites -- All DOE Office Websites (Extended Search)

Accommodations / Hours / Maps Accommodations / Hours / Maps Stanford Guest House This comfortable and convenient housing structure is located on SLAC's campus. Guests have access to in-room, high-speed Internet access, a fitness center, a 24-hour reception desk, laundry facilities, free parking, complimentary tea and coffee, and a 24-hour gift shop. The Guest House offers single as well as shared rooms, but all rooms have their own bathroom, and at very reasonable rates. All rooms are non-smoking only. Please reserve accommodations using their on-line form. If the Guest House is not available, additional accommodations may be made at local hotels/motels. For longer term visits, please contact the User Research Administration office. Gate Hours Maps & Directions SLAC Maps Directions to SLAC Security Gate 17

347

Commercial Buildings Energy Consumption Survey (CBECS) - U.S. Energy  

Gasoline and Diesel Fuel Update (EIA)

Survey Background and Technical Information Survey Background and Technical Information Survey Background The commercial sector encompasses a vast range of building types-service businesses, such as retail and wholesale stores, hotels and motels, restaurants, and hospitals, as well as certain buildings that would not be considered "commercial" in a traditional economic sense, such as public and private schools, correctional institutions, and religious and fraternal organizations. Excluded from the sector are the goods-producing industries: manufacturing, agriculture, mining, forestry and fisheries, and construction. Nearly all energy use in the commercial sector takes place in, or is associated with, the buildings that house these commercial activities. Analysis of the structures, activities, and equipment associated with

348

Heater/cooler unit  

SciTech Connect

Air conditioning apparatus especially adapted for cooling adjacent rooms in a motel, hotel, hospital or like structure is described comprising: a first evaporator disposed in one room; a second evaporator disposed in an adjacent room; a condenser disposed outside the rooms but in fluid communication with both the first and second evaporators; a compressor disposed outside the rooms but in fluid communication with the condenser and with a return side of the first and second evaporators; control means for controlling the fluid flow through each evaporator, the control means permitting fluid flow through the first evaporator to be controlled independently of fluid flow through the second evaporator; and a housing exposed to the atmosphere through the exterior wall of the structure and forming a portion of the common interior wall of the rooms, the evaporators, condenser, compressor, and control means being disposed within the housing.

Mintz, A.

1988-01-26T23:59:59.000Z

349

Order Module--DOE O 440.1B, WORKER PROTECTION PROGRAM FOR DOE (INCLUDING  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Order Module--DOE O 440.1B, WORKER PROTECTION PROGRAM FOR DOE Order Module--DOE O 440.1B, WORKER PROTECTION PROGRAM FOR DOE (INCLUDING NNSA) FEDERAL EMPLOYEES Order Module--DOE O 440.1B, WORKER PROTECTION PROGRAM FOR DOE (INCLUDING NNSA) FEDERAL EMPLOYEES The familiar level of this module is divided into two sections. In the first section, we will discuss the objective, requirements, and the responsibilities assigned to the heads of field elements. In the second section, we will discuss the content of attachment 1, Functional Area Requirements. We have provided examples and a practice to help familiarize you with the material. The practice will also help prepare you for the criterion test. DOE Order Self Study Modules - DOE O 440.1B, Worker Protection Management for DOE (Including the National Nuclear Security Administration) Federal

350

C3E also includes a network of leaders from the public, private, non-profit  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

C3E also includes a network of leaders from the public, private, non-profit, C3E also includes a network of leaders from the public, private, non-profit, and academic sectors who support advocacy, research, scholarships, hands-on training, funding, and networking opportunities to prepare and inspire young women to enter and thrive in STEM fields. C3E Network participants have pledged many types of commitments, from highlighting female role models to creating hands-on activities for young girls. Ongoing activities include: * Filming and featuring women in clean energy fields on online / TV outlets (Earth Day Network); * Designing pilot projects and expanding Young Women's Conferences at DOE's

351

Including Alternative Resources in State Renewable Portfolio Standards: Current Design and Implementation Experience  

NLE Websites -- All DOE Office Websites (Extended Search)

Including Alternative Resources Including Alternative Resources in State Renewable Portfolio Standards: Current Design and Implementation Experience Jenny Heeter and Lori Bird Technical Report NREL/TP-6A20-55979 November 2012 NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency & Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. National Renewable Energy Laboratory 15013 Denver West Parkway Golden, Colorado 80401 303-275-3000 * www.nrel.gov Contract No. DE-AC36-08GO28308 Including Alternative Resources in State Renewable Portfolio Standards: Current Design and Implementation Experience Jenny Heeter and Lori Bird Prepared under Task No. SAO9.3110

352

Introduction to Small-Scale Wind Energy Systems (Including RETScreen Case  

Open Energy Info (EERE)

Introduction to Small-Scale Wind Energy Systems (Including RETScreen Case Introduction to Small-Scale Wind Energy Systems (Including RETScreen Case Study) (Webinar) Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Introduction to Small-Scale Wind Energy Systems (Including RETScreen Case Study) (Webinar) Focus Area: Renewable Energy Topics: System & Application Design Website: www.leonardo-energy.org/webinar-introduction-small-scale-wind-energy-s Equivalent URI: cleanenergysolutions.org/content/introduction-small-scale-wind-energy- Language: English Policies: Deployment Programs DeploymentPrograms: Project Development This video teaches the viewer about wind turbines and RETscreen's wind module, which can be used to project the cost and production of a wind

353

The American Recovery and Reinvestment Act Includes $4.5 billion for the  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

The American Recovery and Reinvestment Act Includes $4.5 billion The American Recovery and Reinvestment Act Includes $4.5 billion for the Office of Electricity Delivery and Energy Reliability The American Recovery and Reinvestment Act Includes $4.5 billion for the Office of Electricity Delivery and Energy Reliability February 25, 2009 - 4:52pm Addthis President Barack Obama signed into law the American Recovery and Reinvestment Act of 2009 (P.L.111-5). The $787 billion economic recovery package represents the largest and most ambitious effort to stimulate the economy in United States history. The Department of Energy (DOE) will be responsible for implementing over $38 billion of the $787 billion package. Of the DOE total, $4.5 Billion is allotted to the Office of Electricity Delivery and Energy Reliability. As outlined in the legislation, these funds are an investment in a

354

Order Module--DOE O 440.1B, WORKER PROTECTION PROGRAM FOR DOE (INCLUDING  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

40.1B, WORKER PROTECTION PROGRAM FOR DOE 40.1B, WORKER PROTECTION PROGRAM FOR DOE (INCLUDING NNSA) FEDERAL EMPLOYEES Order Module--DOE O 440.1B, WORKER PROTECTION PROGRAM FOR DOE (INCLUDING NNSA) FEDERAL EMPLOYEES The familiar level of this module is divided into two sections. In the first section, we will discuss the objective, requirements, and the responsibilities assigned to the heads of field elements. In the second section, we will discuss the content of attachment 1, Functional Area Requirements. We have provided examples and a practice to help familiarize you with the material. The practice will also help prepare you for the criterion test. DOE Order Self Study Modules - DOE O 440.1B, Worker Protection Management for DOE (Including the National Nuclear Security Administration) Federal Employees

355

1) What are the current and future communications needs of utilities, including  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

(1) What are the current and future communications needs of utilities, including for the (1) What are the current and future communications needs of utilities, including for the deployment of new Smart Grid applications, and how are these needs being met? The current communication needs of SCE include: telephony, data, video, voice dispatch, mobile data, grid monitoring, grid control, tele-protection, customer communication, load management, automated meter reading, and collaboration capabilities ranging from virtual meetings to e-learning. SCE is using a combination of private, leased, and shared telecommunication networks to support these requirements. Those applications that require high availability, low latency, and stringent security rely on a private telecommunications network (SCEnet). A combination of transport media are

356

Fourier and Cauchy-Stieltjes transforms of power laws including stable distributions  

E-Print Network (OSTI)

We introduce a class of probability measures whose densities near infinity are mixtures of Pareto distributions. This class can be characterized by the Fourier transform which has a power series expansion including real powers, not only integer powers. This class includes stable distributions in probability and also non-commutative probability theories. We also characterize the class in terms of the Cauchy-Stieltjes transform and the Voiculescu transform. If the stability index is greater than one, stable distributions in probability theory do not belong to that class, while they do in non-commutative probability.

Takahiro Hasebe

2011-07-20T23:59:59.000Z

357

Prototype solar heating and cooling systems, including potable hot water. Quarterly report  

DOE Green Energy (OSTI)

The progress made in the development, delivery and support of two prototype solar heating and cooling systems including potable hot water is reported. The system consists of the following subsystems: collector, auxiliary heating, potable hot water, storage, control, transport, and government-furnished site data acquisition. Included is a comparison of the proposed Solaron-Heat Pump and Solaron-Desiccant Heating and Cooling Systems, Installation Drawings, data on the Akron House at Akron, Ohio, and other program activities from July 1, 1977 through November 9, 1977.

Not Available

1977-12-01T23:59:59.000Z

358

Combinatorial evaluation of systems including decomposition of a system representation into fundamental cycles  

DOE Patents (OSTI)

One embodiment of the present invention includes a computer operable to represent a physical system with a graphical data structure corresponding to a matroid. The graphical data structure corresponds to a number of vertices and a number of edges that each correspond to two of the vertices. The computer is further operable to define a closed pathway arrangement with the graphical data structure and identify each different one of a number of fundamental cycles by evaluating a different respective one of the edges with a spanning tree representation. The fundamental cycles each include three or more of the vertices.

Oliveira, Joseph S. (Richland, WA); Jones-Oliveira, Janet B. (Richland, WA); Bailey, Colin G. (Wellington, NZ); Gull, Dean W. (Seattle, WA)

2008-07-01T23:59:59.000Z

359

Prototype solar heating and cooling systems including potable hot water. Quarterly reports  

DOE Green Energy (OSTI)

The activities conducted by Solaron Corporation from November 1977 through September 1978 are summarized and the progress made in the development, delivery and support of two prototype solar heating and cooling systems including potable hot water is covered. The system consists of the following subsystems: solar collector, auxiliary heating, potable hot water, storage, control, transport, and government-furnished site data acquisition.

Williamson, R.

1978-10-01T23:59:59.000Z

360

Solar Energy Education. Industrial arts: teacher's guide. Field test edition. [Includes glossary  

SciTech Connect

An instructional aid is presented which integrates the subject of solar energy into the classroom study of industrial arts. This guide for teachers was produced in addition to the student activities book for industrial arts by the USDOE Solar Energy Education. A glossary of solar energy terms is included. (BCS)

1981-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "include hotels motels" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

A Flux Parameterization Including the Effects of Capillary Waves and Sea State  

Science Conference Proceedings (OSTI)

An airsea interaction model that includes turbulent transport due to capillary waves (surface ripples) is developed. The model differs from others in that the physical premises are applicable to low wind speeds (10-m wind speed, U10 < 5 m s?1) ...

Mark A. Bourassa; Dayton G. Vincent; W. L. Wood

1999-05-01T23:59:59.000Z

362

ECOVILLAGE FACTS The complex includes 50 apartments (18 original and 32 new)  

E-Print Network (OSTI)

, community gatherings o Kitchen o Playroom o Dryers for Ecovillage residents o Solar water heater o Solar of the Ecovillage apartments include: o solar tubes and compact fluorescent lighting o low-flow toilets College-harvested wood o natural building techniques o a composting toilet o a net-metering solar electric

Baltisberger, Jay H.

363

Solar Energy Education. Home economics: teacher's guide. Field test edition. [Includes glossary  

SciTech Connect

An instructional aid is provided for home economics teachers who wish to integrate the subject of solar energy into their classroom activities. This teacher's guide was produced along with the student activities book for home economics by the US Department of Energy Solar Energy Education. A glossary of solar energy terms is included. (BCS)

1981-06-01T23:59:59.000Z

364

Method of preparing a negative electrode including lithium alloy for use within a secondary electrochemical cell  

DOE Patents (OSTI)

A negative electrode that includes a lithium alloy as active material is prepared by briefly submerging a porous, electrically conductive substrate within a melt of the alloy. Prior to solidification, excess melt can be removed by vibrating or otherwise manipulating the filled substrate to expose interstitial surfaces. Electrodes of such as solid lithium-aluminum filled within a substrate of metal foam are provided.

Tomczuk, Zygmunt (Palos Hills, IL); Olszanski, Theodore W. (Roselle, IL); Battles, James E. (Oak Forest, IL)

1977-03-08T23:59:59.000Z

365

Postgraduate Handbook Courses, programs and any arrangements for programs including staff  

E-Print Network (OSTI)

corn oil; Camelina oil. One of the following: Trans-Esterification, Esterification, Hydrotreating-process renewable biomass and petroleum. 5 POTENTIALLY RELEVANT I Naphtha, LPG Camelina oil Hydrotreating 5 including peat, dung, plant-oils, bees wax, rendered animal fats, draft animals, natural derived sources

Benatallah, Boualem

366

Solar Energy Education. Industrial arts: teacher's guide. Field test edition. [Includes glossary  

DOE Green Energy (OSTI)

An instructional aid is presented which integrates the subject of solar energy into the classroom study of industrial arts. This guide for teachers was produced in addition to the student activities book for industrial arts by the USDOE Solar Energy Education. A glossary of solar energy terms is included. (BCS)

Not Available

1981-05-01T23:59:59.000Z

367

QUALITATIVE PROPERTIES OF A 3-STEPS MODEL OF ANAEROBIC DIGESTION INCLUDING HYDROLYSIS OF PARTICULATE MATTER  

E-Print Network (OSTI)

QUALITATIVE PROPERTIES OF A 3-STEPS MODEL OF ANAEROBIC DIGESTION INCLUDING HYDROLYSIS-SupAgro MISTEA, 2 p. Viala 34060 Montpellier, France, fekih@supagro.inra.fr Introduction. Anaerobic digestion, the anaerobic digestion is generally considered as a three step process: hydrolysis and liquefaction

Paris-Sud XI, Université de

368

ON THE STANDARD METABOLIC RATES OF TROPICAL TUNAS, INCLUDING THE EFFECf OF BODY SIZE AND  

E-Print Network (OSTI)

ON THE STANDARD METABOLIC RATES OF TROPICAL TUNAS, INCLUDING THE EFFECf OF BODY SIZE AND ACUTE. This study was undertaken to obtain these data for the tropical tuna species, yellowfin tuna, Tkunnl tuna, KatsltWOO1t8 pelamis, previously published. The effect of acute temperature change on the SMR

369

Faddeev-type calculations of few-body nuclear reactions including Coulomb interaction  

E-Print Network (OSTI)

The method of screening and renormalization is used to include the Coulomb interaction between the charged particles in the description of few-body nuclear reactions. Calculations are done in the framework of Faddeev-type equations in momentum-space. The reliability of the method is demonstrated. The Coulomb effect on observables is discussed.

A. Deltuva

2008-10-24T23:59:59.000Z

370

Process, including PSA and membrane separation, for separating hydrogen from hydrocarbons  

DOE Patents (OSTI)

An improved process for separating hydrogen from hydrocarbons. The process includes a pressure swing adsorption step, a compression/cooling step and a membrane separation step. The membrane step relies on achieving a methane/hydrogen selectivity of at least about 2.5 under the conditions of the process.

Baker, Richard W. (Palo Alto, CA); Lokhandwala, Kaaeid A. (Union City, CA); He, Zhenjie (Fremont, CA); Pinnau, Ingo (Palo Alto, CA)

2001-01-01T23:59:59.000Z

371

CHEMICAL WASTE RECYCLING PROGRAM EMPTY CHEMICAL BOTTLES: which include all glass, plastic and metal bottles that  

E-Print Network (OSTI)

CHEMICAL WASTE RECYCLING PROGRAM EMPTY CHEMICAL BOTTLES: which include all glass, plastic and metal bottles that previously contained chemicals (hazardous or non-hazardous) are collected by CWS for recycling. Bottles should be dry and empty without chemical residue. Rinse and collect rinsate in chemical

Ungerleider, Leslie G.

372

Selecting Optional Fees Optional fees include meal plans, money on Tigerstripe, and a TAPS yearbook. All  

E-Print Network (OSTI)

supports all of the services at Redfern and includes: · Professional services of primary health care on pharmaceuticals, psychological testing, laboratory and x- ray services. · After Hours Nursewise telephone service. http://sisweb.clemson.edu/ Health Fee Policy University policy requires all students registered for six

Bolding, M. Chad

373

Solar water heater installation guidelines. A manual for homeowners and professionals. [Includes glossary  

SciTech Connect

The guidelines include detailed diagrams, a selected glossary, a bibliography of books and manuals which might prove useful and a checklist which should be used during and after the installation. The guidelines explain generally how to install a liquid solar hot water heater, but not a specific system. The following are covered: collector location, collector installation, plumbing, solar storage tanks, electrical, and insulation. (MHR)

1978-04-01T23:59:59.000Z

374

Solar Energy Education. Home economics: teacher's guide. Field test edition. [Includes glossary  

DOE Green Energy (OSTI)

An instructional aid is provided for home economics teachers who wish to integrate the subject of solar energy into their classroom activities. This teacher's guide was produced along with the student activities book for home economics by the US Department of Energy Solar Energy Education. A glossary of solar energy terms is included. (BCS)

Not Available

1981-06-01T23:59:59.000Z

375

Prototype solar heating and cooling systems including potable hot water. Quarterly reports, November 1976--June 1977  

DOE Green Energy (OSTI)

This report covers the progress made in the development, delivery and support of two prototype solar heating and cooling systems including potable hot water. The system consists of the following subsystems: collector, auxiliary heating, potable hot water, storage, control, transport, and government-furnished site data acquisition.

Not Available

1978-12-01T23:59:59.000Z

376

THERMOMECHANICS OF PV MODULES INCLUDING THE VISCOELASTICITY OF EVA Ulrich Eitner1,  

E-Print Network (OSTI)

in the cell distance is 170µm. Keywords: PV module, Encapsulation, Simulation, Reliability, Mechanics 1THERMOMECHANICS OF PV MODULES INCLUDING THE VISCOELASTICITY OF EVA Ulrich Eitner1, *, Matthias by a comparison to displacement experiments where the thermomechanical deformation of solar cells in a PV laminate

377

Seismic fracture analysis of concrete gravity dams including dam-reservoir interaction  

Science Conference Proceedings (OSTI)

In this study, the seismic fracture response of concrete gravity dams is investigated with considering the effects of dam-reservoir interaction. A co-axial rotating crack model (CRCM), which includes the strain softening behavior, is selected for concrete ... Keywords: Concrete gravity dam, Dam-reservoir interaction, Non-linear analysis, Seismic fracture

Yusuf Calayir; Muhammet Karaton

2005-07-01T23:59:59.000Z

378

Security and Access Policy Security of and access to campus facilities, including campus residences  

E-Print Network (OSTI)

Security and Access Policy Security of and access to campus facilities, including campus residences facilities. Residence halls are secured 24 hours a day. Over extended breaks, the doors of all residence halls will be secured around the clock. Some facilities may have individual hours, which may vary

Escher, Christine

379

The Fuels and Lubricants Research Division of Southwest Research includes extensive engines, fuels and lubricants research,  

E-Print Network (OSTI)

Caterpillar 1K Lubricant Test This test evaluates the piston deposits, liner wear, and oil consumption and oil consumption. The test is proposed for inclusion in the PC-10 category. Mack T8/T8A/T8E Lubricant of Mack engine oil specification EON+ 03, CI-4+ and will be included in PC-10. Mack T12 Lubricant Test

Chapman, Clark R.

380

Policy Flash 2013-49 Updating Reporting Requirement Checklist including the  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Policy Flash 2013-49 Updating Reporting Requirement Checklist Policy Flash 2013-49 Updating Reporting Requirement Checklist including the research performance progress report Policy Flash 2013-49 Updating Reporting Requirement Checklist including the research performance progress report Questions concerning this policy flash should be directed to Ellen Colligan, of the Contract and Financial Assistance Policy Division, Office of Contract Management, Office of Acquisition and Project Management at (202) 287-1776, Ellen.colligan@hq.doe.gov Policy Flash 2013-49.pdf Attch_FA_RepReqChecklist_COMBINED_FINAL_4-23-13 (3).pdf More Documents & Publications ATTACHMENT FLASH 2011-46(6) Federal Assistance Reporting Checklist and Instructions for Projects Federal Assistance Reporting Checklist and Instructions for RD&D Projects

Note: This page contains sample records for the topic "include hotels motels" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Hydraulically actuated fuel injector including a pilot operated spool valve assembly and hydraulic system using same  

DOE Patents (OSTI)

The present invention relates to hydraulic systems including hydraulically actuated fuel injectors that have a pilot operated spool valve assembly. One class of hydraulically actuated fuel injectors includes a solenoid driven pilot valve that controls the initiation of the injection event. However, during cold start conditions, hydraulic fluid, typically engine lubricating oil, is particularly viscous and is often difficult to displace through the relatively small drain path that is defined past the pilot valve member. Because the spool valve typically responds slower than expected during cold start due to the difficulty in displacing the relatively viscous oil, accurate start of injection timing can be difficult to achieve. There also exists a greater difficulty in reaching the higher end of the cold operating speed range. Therefore, the present invention utilizes a fluid evacuation valve to aid in displacement of the relatively viscous oil during cold start conditions.

Shafer, Scott F. (Morton, IL)

2002-01-01T23:59:59.000Z

382

Method for pulse control in a laser including a stimulated brillouin scattering mirror system  

DOE Patents (OSTI)

A laser system, such as a master oscillator/power amplifier system, comprises a gain medium and a stimulated Brillouin scattering SBS mirror system. The SBS mirror system includes an in situ filtered SBS medium that comprises a compound having a small negative non-linear index of refraction, such as a perfluoro compound. An SBS relay telescope having a telescope focal point includes a baffle at the telescope focal point which blocks off angle beams. A beam splitter is placed between the SBS mirror system and the SBS relay telescope, directing a fraction of the beam to an alternate beam path for an alignment fiducial. The SBS mirror system has a collimated SBS cell and a focused SBS cell. An adjustable attenuator is placed between the collimated SBS cell and the focused SBS cell, by which pulse width of the reflected beam can be adjusted.

Dane, C. Brent (Livermore, CA); Hackel, Lloyd (Livermore, CA); Harris, Fritz B. (Rocklin, CA)

2007-10-23T23:59:59.000Z

383

" Row: End Uses;" " Column: Energy Sources, including Net Electricity;"  

U.S. Energy Information Administration (EIA) Indexed Site

5 End Uses of Fuel Consumption, 2010;" 5 End Uses of Fuel Consumption, 2010;" " Level: National and Regional Data; " " Row: End Uses;" " Column: Energy Sources, including Net Electricity;" " Unit: Physical Units or Btu." " "," ",," ","Distillate"," "," ","Coal"," " " ",,,,"Fuel Oil",,,"(excluding Coal" " "," ","Net","Residual","and","Natural Gas(c)","LPG and","Coke and Breeze)"," " " ","Total","Electricity(a)","Fuel Oil","Diesel Fuel(b)","(billion","NGL(d)","(million","Other(e)"

384

" Row: End Uses;" " Column: Energy Sources, including Net Electricity;"  

U.S. Energy Information Administration (EIA) Indexed Site

5 End Uses of Fuel Consumption, 2002;" 5 End Uses of Fuel Consumption, 2002;" " Level: National and Regional Data; " " Row: End Uses;" " Column: Energy Sources, including Net Electricity;" " Unit: Physical Units or Btu." " "," ",," ","Distillate"," "," ",," "," " " ",,,,"Fuel Oil",,,"Coal" " "," ","Net","Residual","and","Natural ","LPG and","(excluding Coal"," ","RSE" " ","Total","Electricity(a)","Fuel Oil","Diesel Fuel(b)","Gas(c)","NGL(d)","Coke and Breeze)","Other(e)","Row"

385

" Row: End Uses;" " Column: Energy Sources, including Net Electricity;"  

U.S. Energy Information Administration (EIA) Indexed Site

6 End Uses of Fuel Consumption, 2010;" 6 End Uses of Fuel Consumption, 2010;" " Level: National and Regional Data; " " Row: End Uses;" " Column: Energy Sources, including Net Electricity;" " Unit: Trillion Btu." " "," ",," ","Distillate"," "," ",," " " ",,,,"Fuel Oil",,,"Coal" " "," ","Net","Residual","and",,"LPG and","(excluding Coal"," " "End Use","Total","Electricity(a)","Fuel Oil","Diesel Fuel(b)","Natural Gas(c)","NGL(d)","Coke and Breeze)","Other(e)"

386

" Row: End Uses;" " Column: Energy Sources, including Net Electricity;"  

U.S. Energy Information Administration (EIA) Indexed Site

6 End Uses of Fuel Consumption, 2002;" 6 End Uses of Fuel Consumption, 2002;" " Level: National and Regional Data; " " Row: End Uses;" " Column: Energy Sources, including Net Electricity;" " Unit: Trillion Btu." " "," ",," ","Distillate"," "," ",," "," " " ",,,,"Fuel Oil",,,"Coal",,"RSE" " "," ","Net","Residual","and","Natural ","LPG and","(excluding Coal"," ","Row" "End Use","Total","Electricity(a)","Fuel Oil","Diesel Fuel(b)","Gas(c)","NGL(d)","Coke and Breeze)","Other(e)","Factors"

387

" Row: End Uses;" " Column: Energy Sources, including Net Electricity;"  

U.S. Energy Information Administration (EIA) Indexed Site

5 End Uses of Fuel Consumption, 2006;" 5 End Uses of Fuel Consumption, 2006;" " Level: National and Regional Data; " " Row: End Uses;" " Column: Energy Sources, including Net Electricity;" " Unit: Physical Units or Btu." " "," ",," ","Distillate"," "," ","Coal"," " " ",,,,"Fuel Oil",,,"(excluding Coal" " "," ","Net","Residual","and","Natural Gas(c)","LPG and","Coke and Breeze)"," " " ","Total","Electricity(a)","Fuel Oil","Diesel Fuel(b)","(billion","NGL(d)","(million","Other(e)"

388

" Row: End Uses;" " Column: Energy Sources, including Net Electricity;"  

U.S. Energy Information Administration (EIA) Indexed Site

6 End Uses of Fuel Consumption, 2006;" 6 End Uses of Fuel Consumption, 2006;" " Level: National and Regional Data; " " Row: End Uses;" " Column: Energy Sources, including Net Electricity;" " Unit: Trillion Btu." " "," ",," ","Distillate"," "," ",," " " ",,,,"Fuel Oil",,,"Coal" " "," ","Net","Residual","and",,"LPG and","(excluding Coal"," " "End Use","Total","Electricity(a)","Fuel Oil","Diesel Fuel(b)","Natural Gas(c)","NGL(d)","Coke and Breeze)","Other(e)"

389

" Row: End Uses;" " Column: Energy Sources, including Net Electricity;"  

U.S. Energy Information Administration (EIA) Indexed Site

1. End Uses of Fuel Consumption, 1998;" 1. End Uses of Fuel Consumption, 1998;" " Level: National and Regional Data; " " Row: End Uses;" " Column: Energy Sources, including Net Electricity;" " Unit: Physical Units or Btu." " "," ",," ","Distillate"," "," ","Coal"," "," " " ",,,,"Fuel Oil",,,"(excluding Coal" " "," ","Net","Residual","and","Natural Gas(c)","LPG and","Coke and Breeze)"," ","RSE" " ","Total","Electricity(a)","Fuel Oil","Diesel Fuel(b)","(billion","NGL(d)","(million","Other(e)","Row"

390

" Row: End Uses;" " Column: Energy Sources, including Net Electricity;"  

U.S. Energy Information Administration (EIA) Indexed Site

2. End Uses of Fuel Consumption, 1998;" 2. End Uses of Fuel Consumption, 1998;" " Level: National and Regional Data; " " Row: End Uses;" " Column: Energy Sources, including Net Electricity;" " Unit: Trillion Btu." " "," ",," ","Distillate"," "," ",," "," " " ",,,,"Fuel Oil",,,"Coal",,"RSE" " "," ","Net","Residual","and",,"LPG and","(excluding Coal"," ","Row" "End Use","Total","Electricity(a)","Fuel Oil","Diesel Fuel(b)","Natural Gas(c)","NGL(d)","Coke and Breeze)","Other(e)","Factors"

391

2008 CIM-XML Interoperability Including CIM-Based Tools Test  

Science Conference Proceedings (OSTI)

EPRI Initiatives have produced a number of drafts that have now become International Electrotechnical Commission (IEC) standards, including the Common Information Model (CIM) and the Generic Interface Definition (GID) specifications. These standards provide the basis for model-driven information exchange both within and between control centers and other systems in utility operations across the enterprise. Previous interoperability tests validated the use and acceptance of the CIM standard translated into...

2008-12-04T23:59:59.000Z

392

Method of preparing a negative electrode including lithium alloy for use within a secondary electrochemical cell  

DOE Patents (OSTI)

A negative electrode that includes a lithium alloy as active material is prepared by briefly submerging a porous, electrically conductive substrate within a melt of the alloy. Prior to solidification, excess melt can be removed by vibrating or otherwise manipulating the filled substrate to expose interstitial surfaces. Electrodes of such a solid lithium--aluminum filled within a substrate of metal foam are provided. 1 figure, 1 table.

Tomczuk, Z.; Olszanski, W.; Battles, J.E.

1975-12-09T23:59:59.000Z

393

Impact of supersonic and subsonic aircraft on ozone: Including heterogeneous chemical reaction mechanisms  

Science Conference Proceedings (OSTI)

Preliminary calculations suggest that heterogeneous reactions are important in calculating the impact on ozone from emissions of trace gases from aircraft fleets. In this study, three heterogeneous chemical processes that occur on background sulfuric acid aerosols are included and their effects on O{sub 3}, NO{sub x}, Cl{sub x}, HCl, N{sub 2}O{sub 5}, ClONO{sub 2} are calculated.

Kinnison, D.E.; Wuebbles, D.J.

1992-07-05T23:59:59.000Z

394

Nuclear Maintenance Applications Center: Motor Management Guide Supporting Plant License Renewal Including Environmental Qualification Considerations  

Science Conference Proceedings (OSTI)

This report was developed by the Electric Power Research Institutes Large Electric Motor Users Group Information Working Group, which includes motor engineers, motor specialist consultants, and vendors. Environmental qualification (EQ) program owners were also involved in the development of this report. This report addresses the most important elements of a sound motor management program to support an informed decision on motor preservation and motor life extension. Motor life extensions of ...

2013-06-07T23:59:59.000Z

395

Method for including operation and maintenance costs in the economic analysis of active solar energy systems  

DOE Green Energy (OSTI)

For a developing technology such as solar energy, the costs for operation and maintenance (O and M) can be substantial. In the past, most economic analyses included these costs by simply assuming that an annual cost will be incurred that is proportional to the initial cost of the system. However, in assessing the economics of new systems proposed for further research and development, such a simplification can obscure the issues. For example, when the typical method for including O and M costs in an economic analysis is used, the O and M costs associated with a newly developed, more reliable, and slightly more expensive controller will be assumed to increase - an obvious inconsistency. The method presented in this report replaces this simplistic approach with a representation of the O and M costs that explicitly accounts for the uncertainties and risks inherent in the operation of any equipment. A detailed description of the data inputs required by the method is included as well as a summary of data sources and an example of the method as applied to an active solar heating system.

Short, W.D.

1986-08-01T23:59:59.000Z

396

Method and system including a double rotary kiln pyrolysis or gasification of waste material  

DOE Patents (OSTI)

A method of destructively distilling an organic material in particulate form wherein the particulates are introduced through an inlet into one end of an inner rotating kiln ganged to and coaxial with an outer rotating kiln. The inner and outer kilns define a cylindrical annular space with the inlet being positioned in registry with the axis of rotation of the ganged kilns. During operation, the temperature of the wall of the inner rotary kiln at the inlet is not less than about 500.degree. C. to heat the particulate material to a temperature in the range of from about 200.degree. C. to about 900.degree. C. in a pyrolyzing atmosphere to reduce the particulate material as it moves from the one end toward the other end. The reduced particulates including char are transferred to the annular space between the inner and the outer rotating kilns near the other end of the inner rotating kiln and moved longitudinally in the annular space from near the other end toward the one end in the presence of oxygen to combust the char at an elevated temperature to produce a waste material including ash. Also, heat is provided which is transferred to the inner kiln. The waste material including ash leaves the outer rotating kiln near the one end and the pyrolysis vapor leaves through the particulate material inlet.

McIntosh, Michael J. (Bolingbrook, IL); Arzoumanidis, Gregory G. (Naperville, IL)

1997-01-01T23:59:59.000Z

397

Method and system including a double rotary kiln pyrolysis or gasification of waste material  

DOE Patents (OSTI)

A method is described for destructively distilling an organic material in particulate form wherein the particulates are introduced through an inlet into one end of an inner rotating kiln ganged to and coaxial with an outer rotating kiln. The inner and outer kilns define a cylindrical annular space with the inlet being positioned in registry with the axis of rotation of the ganged kilns. During operation, the temperature of the wall of the inner rotary kiln at the inlet is not less than about 500 C to heat the particulate material to a temperature in the range of from about 200 C to about 900 C in a pyrolyzing atmosphere to reduce the particulate material as it moves from the one end toward the other end. The reduced particulates including char are transferred to the annular space between the inner and the outer rotating kilns near the other end of the inner rotating kiln and moved longitudinally in the annular space from near the other end toward the one end in the presence of oxygen to combust the char at an elevated temperature to produce a waste material including ash. Also, heat is provided which is transferred to the inner kiln. The waste material including ash leaves the outer rotating kiln near the one end and the pyrolysis vapor leaves through the particulate material inlet. 5 figs.

McIntosh, M.J.; Arzoumanidis, G.G.

1997-09-02T23:59:59.000Z

398

A method and system including a double rotary kiln pyrolysis or gasification of waste material  

DOE Patents (OSTI)

A method is described for destructively distilling an organic material in particulate form wherein the particulates are introduced through an inlet into one end of an inner rotating kiln ganged to and coaxial with an outer rotating kiln. The inner and outer kilns define a cylindrical annular space with the inlet being positioned in registry with the axis of rotation of the ganged kilns. During operation, the temperature of the wall of the inner rotary kiln at the inlet is not less than about 500 C to heat the particulate material to a temperature in the range of from about 200 C to about 900 C in a pyrolyzing atmosphere to reduce the particulate material as it moves from the one end toward the other end. The reduced particulates including char are transferred to the annular space between the inner and the outer rotating kilns near the other end of the inner rotating kiln and moved longitudinally in the annular space from near the other end toward the one end in the presence of oxygen to combust the char at an elevated temperature to produce a waste material including ash. Also, heat is provided which is transferred to the inner kiln. The waste material including ash leaves the outer rotating kiln near the one end and the pyrolysis vapor leaves through the particulate material inlet.

McIntosh, M.J.; Arzoumanidis, G.G.

1995-12-31T23:59:59.000Z

399

Microelectromechanical accelerometer with resonance-cancelling control circuit including an idle state  

DOE Patents (OSTI)

A digital feedback control circuit is disclosed for use in an accelerometer (e.g. a microelectromechanical accelerometer). The digital feedback control circuit, which periodically re-centers a proof mass in response to a sensed acceleration, is based on a sigma-delta (.SIGMA..DELTA.) configuration that includes a notch filter (e.g. a digital switched-capacitor filter) for rejecting signals due to mechanical resonances of the proof mass and further includes a comparator (e.g. a three-level comparator). The comparator generates one of three possible feedback states, with two of the feedback states acting to re-center the proof mass when that is needed, and with a third feedback state being an "idle" state which does not act to move the proof mass when no re-centering is needed. Additionally, the digital feedback control system includes an auto-zero trim capability for calibration of the accelerometer for accurate sensing of acceleration. The digital feedback control circuit can be fabricated using complementary metal-oxide semiconductor (CMOS) technology, bi-CMOS technology or bipolar technology and used in single- and dual-proof-mass accelerometers.

Chu, Dahlon D. (Albuquerque, NM); Thelen, Jr., Donald C. (Bozeman, MT); Campbell, David V. (Albuquerque, NM)

2001-01-01T23:59:59.000Z

400

Swozzle based burner tube premixer including inlet air conditioner for low emissions combustion  

DOE Patents (OSTI)

A burner for use in a combustion system of a heavy-duty industrial gas turbine includes a fuel/air premixer having an air inlet, a fuel inlet, and an annular mixing passage. The fuel/air premixer mixes fuel and air into a uniform mixture for injection into a combustor reaction zone. The burner also includes an inlet flow conditioner disposed at the air inlet of the fuel/air premixer for controlling a radial and circumferential distribution of incoming air. The pattern of perforations in the inlet flow conditioner is designed such that a uniform air flow distribution is produced at the swirler inlet annulus in both the radial and circumference directions. The premixer includes a swozzle assembly having a series of preferably air foil shaped turning vanes that impart swirl to the airflow entering via the inlet flow conditioner. Each air foil contains internal fuel flow passages that introduce natural gas fuel into the air stream via fuel metering holes that pass through the walls of the air foil shaped turning vanes. By injecting fuel in this manner, an aerodynamically clean flow field is maintained throughout the premixer. By injecting fuel via two separate passages, the fuel/air mixture strength distribution can be controlled in the radial direction to obtain optimum radial concentration profiles for control of emissions, lean blow outs, and combustion driven dynamic pressure activity as machine and combustor load are varied.

Tuthill, Richard Sterling (Bolton, CT); Bechtel, II, William Theodore (Scotia, NY); Benoit, Jeffrey Arthur (Scotia, NY); Black, Stephen Hugh (Duanesburg, NY); Bland, Robert James (Clifton Park, NY); DeLeonardo, Guy Wayne (Scotia, NY); Meyer, Stefan Martin (Troy, NY); Taura, Joseph Charles (Clifton Park, NY); Battaglioli, John Luigi (Glenville, NY)

2002-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "include hotels motels" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Microwave technology for waste management applications including disposition of electronic circuitry  

SciTech Connect

Microwave technology is being developed nationally and internationally for a variety of environmental remediation purposes. These efforts include treatment and destruction of a vast array of gaseous, liquid and solid hazardous wastes as well as subsequent immobilization of selected components. Microwave technology provides an important contribution to an arsenal of existing remediation methods that are designed to protect the public and environment from undesirable consequences of hazardous materials. Applications of microwave energy for environmental remediation will be discussed. Emphasized will be a newly developed microwave process designed to treat discarded electronic circuitry and reclaim the precious metals within for reuse.

Wicks, G.G. [Westinghouse Savannah River Co., Aiken, SC (United States); Clark, D.E.; Schulz, R.L.; Folz, D.C. [Univ. of Florida, Gainesville, FL (United States)

1995-09-01T23:59:59.000Z

402

X-ray Thomson scattering for partially ionized plasmas including the effect of bound levels  

E-Print Network (OSTI)

X-ray Thomson scattering is being developed as a method to measure the temperature, electron density, and ionization state of high energy density plasmas such as those used in inertial confinement fusion. Most experiments are currently done at large laser facilities that can create bright X-ray sources, however the advent of the X-ray free electron laser (X-FEL) provides a new bright source to use in these experiments. One challenge with X-ray Thomson scattering experiments is understanding how to model the scattering for partially ionized plasmas in order to include the contributions of the bound electrons in the scattered intensity. In this work we take the existing models of Thomson scattering that include elastic ion-ion scattering and the electron-electron plasmon scattering and add the contribution of the bound electrons in the partially ionized plasmas. We validated our model by analyzing existing beryllium experimental data. We then consider several higher Z materials such as Cr and predict the existe...

Nilsen, J; Cheng, K T

2013-01-01T23:59:59.000Z

403

Segmented instrumentation tube including a locking sleeve for interlocking the segments of the instrumentation tube  

DOE Patents (OSTI)

Segmented instrumentation tube including a locking sleeve for interlocking the segments of the instrumentation tube, so that the threaded ends of the instrumentation tube do not unthread when subjected to vibration, such an instrumentation tube being suitable for use in a nuclear reactor pressure vessel. The instrumentation tube has a first member having a threaded end portion that has a plurality of first holes circumferentially around the outside surface thereof. The instrumentation tube also has a second member having a threaded end portion that has a plurality of second holes circumferentially around the outside surface thereof. The threads of the second member are caused to threadably engage the threads of the first member for defining a threaded joint therebetween. A sleeve having an inside surface surrounds the end portion of the first member and the end portion of the second member and thus surrounds the threaded joint. The sleeve includes a plurality of first projections and second projections that outwardly extend from the inside surface to engage the first holes and the second holes, respectively. The outside surface of the sleeve is crimped or swaged at the locations of the first projections and second projections such that the first projections and the second projections engage their respective holes. In this manner, independent rotation of the first member with respect to the second member is prevented, so that the instrumentation tube will not unthread at its threaded joint.

Obermeyer, Franklin D. (Pensacola, FL)

1993-01-01T23:59:59.000Z

404

An Evaluation of Molten-Salt Power Towers Including Results of the Solar Two Project  

DOE Green Energy (OSTI)

This report utilizes the results of the Solar Two project, as well as continuing technology development, to update the technical and economic status of molten-salt power towers. The report starts with an overview of power tower technology, including the progression from Solar One to the Solar Two project. This discussion is followed by a review of the Solar Two project--what was planned, what actually occurred, what was learned, and what was accomplished. The third section presents preliminary information regarding the likely configuration of the next molten-salt power tower plant. This section draws on Solar Two experience as well as results of continuing power tower development efforts conducted jointly by industry and Sandia National Laboratories. The fourth section details the expected performance and cost goals for the first commercial molten-salt power tower plant and includes a comparison of the commercial performance goals to the actual performance at Solar One and Solar Two. The final section summarizes the successes of Solar Two and the current technology development activities. The data collected from the Solar Two project suggest that the electricity cost goals established for power towers are reasonable and can be achieved with some simple design improvements.

REILLY, HUGH E.; KOLB, GREGORY J.

2001-11-01T23:59:59.000Z

405

RELAP5-3D Code Includes Athena Features and Models  

DOE Green Energy (OSTI)

Version 2.3 of the RELAP5-3D computer program includes all features and models previously available only in the ATHENA version of the code. These include the addition of new working fluids (i.e., ammonia, blood, carbon dioxide, glycerol, helium, hydrogen, lead-bismuth, lithium, lithium-lead, nitrogen, potassium, sodium, and sodium-potassium) and a magnetohydrodynamic model that expands the capability of the code to model many more thermal-hydraulic systems. In addition to the new working fluids along with the standard working fluid water, one or more noncondensable gases (e.g., air, argon, carbon dioxide, carbon monoxide, helium, hydrogen, krypton, nitrogen, oxygen, sf6, xenon) can be specified as part of the vapor/gas phase of the working fluid. These noncondensable gases were in previous versions of RELAP5- 3D. Recently four molten salts have been added as working fluids to RELAP5-3D Version 2.4, which has had limited release. These molten salts will be in RELAP5-3D Version 2.5, which will have a general release like RELAP5-3D Version 2.3. Applications that use these new features and models are discussed in this paper.

Richard A. Riemke; Cliff B. Davis; Richard R. Schultz

2006-07-01T23:59:59.000Z

406

Segmented instrumentation tube including a locking sleeve for interlocking the segments of the instrumentation tube  

DOE Patents (OSTI)

Segmented instrumentation tube including a locking sleeve for interlocking the segments of the instrumentation tube, so that the threaded ends of the instrumentation tube do not unthread when subjected to vibration, such an instrumentation tube being suitable for use in a nuclear reactor pressure vessel. The instrumentation tube has a first member having a threaded end portion that has a plurality of first holes circumferentially around the outside surface thereof. The instrumentation tube also has a second member having a threaded end portion that has a plurality of second holes circumferentially around the outside surface thereof. The threads of the second member are caused to threadably engage the threads of the first member for defining a threaded joint there between. A sleeve having an inside surface surrounds the end portion of the first member and the end portion of the second member and thus surrounds the threaded joint. The sleeve includes a plurality of first projections and second projections that outwardly extend from the inside surface to engage the first holes and the second holes, respectively. The outside surface of the sleeve is crimped or swaged at the locations of the first projections and second projections such that the first projections and the second projections engage their respective holes. In this manner, independent rotation of the first member with respect to the second member is prevented, so that the instrumentation tube will not unthread at its threaded joint. 10 figures.

Obermeyer, F.D.

1993-11-16T23:59:59.000Z

407

Transportation R and D included in thermal and mechanical sciences program  

Science Conference Proceedings (OSTI)

Argonne National Laboratory is a multiprogram research and development laboratory operated by The University of Chicago for the US Department of Energy. At Argonne, applied research in thermal and mechanical sciences is performed within the Thermal and Mechanical Sciences Section of the Energy Technology Division. Current program areas include compact evaporators and condensers for the process and transportation industries, ice slurries for district cooling, advanced fluids for improved heat transfer and reduced pressure drop, flow-induced vibration and flow distribution in shell-and-tube heat exchangers, and dynamics and control of maglev systems. In general, the objective of the research is to extend the technology base in each of these areas and to facilitate its application in solving problems of importance to US industries and utilities. This is accomplished by developing validated design correlations and predictive methods. The staff of the Thermal and Mechanical Sciences Section have extensive experimental and analytical experience in heat transfer, multiphase flow, structural dynamics and control, fluid-structure interaction, transient flow and mixing, thermally driven flows, and flow visualization using ultra-high-speed video. Large, general-purpose test facilities and smaller, single-purpose test apparatuses are available for experiments and component design evaluation. A world-class capability in the study of flow-induced vibrations exists within the Section. Individual fact sheets, describing currently active research program areas, related facilities, and listing, as a contact, the principal investigator, are included.

NONE

1995-03-01T23:59:59.000Z

408

Dye laser amplifier including an improved window configuration for its dye beam  

DOE Patents (OSTI)

A dye laser amplifier in which a continuously replenished supply of dye is excited with a first light beam in order to amplify the intensity of a second different light beam passing therethrough is disclosed herein. This amplifier includes a cell though which a continuous stream of the dye is caused to pass, and means for directing the first beam into the cell while the second beam is directed into and through the same cell. There is also disclosed herein a specific improvement to this amplifier which resides in the use of a pair of particularly configured windows through which the second beam passes along fixed paths as the second beam enters and exits the dye cell. Each of these windows has a relatively thick main section which is substantially larger in dimensions transverse to its beam path than the cross section of the second beam itself, whereby to add structural integrity to the overall window. At the same time, the latter includes a second section which is disposed entirely within the confines of the main section and through which the second beam is intended to pass in its entirety. This second section is made substantially thinner than the main section in order to reduce optical distortion as the second beam passes therethrough.

O' Neil, Richard W. (Pleasanton, CA); Davin, James M. (Livermore, CA)

1992-01-01T23:59:59.000Z

409

Dye laser amplifier including an improved window configuration for its dye beam  

DOE Patents (OSTI)

A dye laser amplifier in which a continuously replenished supply of dye is excited with a first light beam in order to amplify the intensity of a second different light beam passing therethrough is disclosed herein. This amplifier includes a cell though which a continuous stream of the dye is caused to pass, and means for directing the first beam into the cell while the second beam is directed into and through the same cell. There is also disclosed herein a specific improvement to this amplifier which resides in the use of a pair of particularly configured windows through which the second beam passes along fixed paths as the second beam enters and exits the dye cell. Each of these windows has a relatively thick main section which is substantially larger in dimensions transverse to its beam path than the cross section of the second beam itself, whereby to add structural integrity to the overall window. At the same time, the latter includes a second section which is disposed entirely within the confines of the main section and through which the second beam is intended to pass in its entirety. This second section is made substantially thinner than the main section in order to reduce optical distortion as the second beam passes therethrough. 4 figs.

O' Neil, R.W.; Davin, J.M.

1992-12-01T23:59:59.000Z

410

Level: National and Regional Data; Row: End Uses; Column: Energy Sources, including Net Demand for Electricity;  

U.S. Energy Information Administration (EIA) Indexed Site

7 End Uses of Fuel Consumption, 2006; 7 End Uses of Fuel Consumption, 2006; Level: National and Regional Data; Row: End Uses; Column: Energy Sources, including Net Demand for Electricity; Unit: Physical Units or Btu. Distillate Coal Fuel Oil (excluding Coal Net Demand Residual and Natural Gas(c) LPG and Coke and Breeze) for Electricity(a) Fuel Oil Diesel Fuel(b) (billion NGL(d) (million End Use (million kWh) (million bbl) (million bbl) cu ft) (million bbl) short tons) Total United States TOTAL FUEL CONSUMPTION 977,338 40 22 5,357 21 46 Indirect Uses-Boiler Fuel 24,584 21 4 2,059 2 25 Conventional Boiler Use 24,584 11 3 1,245 2 6 CHP and/or Cogeneration Process 0 10 1 814 * 19 Direct Uses-Total Process 773,574 10 9 2,709 10 19 Process Heating

411

Level: National and Regional Data; Row: End Uses; Column: Energy Sources, including Net Electricity;  

U.S. Energy Information Administration (EIA) Indexed Site

5 End Uses of Fuel Consumption, 2006; 5 End Uses of Fuel Consumption, 2006; Level: National and Regional Data; Row: End Uses; Column: Energy Sources, including Net Electricity; Unit: Physical Units or Btu. Distillate Coal Fuel Oil (excluding Coal Net Residual and Natural Gas(c) LPG and Coke and Breeze) Total Electricity(a) Fuel Oil Diesel Fuel(b) (billion NGL(d) (million Other(e) End Use (trillion Btu) (million kWh) (million bbl) (million bbl) cu ft) (million bbl) short tons) (trillion Btu) Total United States TOTAL FUEL CONSUMPTION 15,658 835,382 40 22 5,357 21 46 5,820 Indirect Uses-Boiler Fuel -- 12,109 21 4 2,059 2 25 -- Conventional Boiler Use 12,109 11 3 1,245 2 6 CHP and/or Cogeneration Process 0 10 1 814 * 19 Direct Uses-Total Process

412

Including Alternative Resources in State Renewable Portfolio Standards: Current Design and Implementation Experience  

SciTech Connect

Currently, 29 states, the District of Columbia, and Puerto Rico have instituted a renewable portfolio standard (RPS). An RPS sets a minimum threshold for how much renewable energy must be generated in a given year. Each state policy is unique, varying in percentage targets, timetables, and eligible resources. This paper examines state experience with implementing renewable portfolio standards that include energy efficiency, thermal resources, and non-renewable energy and explores compliance experience, costs, and how states evaluate, measure, and verify energy efficiency and convert thermal energy. It aims to gain insights from the experience of states for possible federal clean energy policy as well as to share experience and lessons for state RPS implementation.

Heeter, J.; Bird, L.

2012-11-01T23:59:59.000Z

413

Level: National and Regional Data; Row: End Uses; Column: Energy Sources, including Net Electricity;  

U.S. Energy Information Administration (EIA) Indexed Site

6 End Uses of Fuel Consumption, 2006; 6 End Uses of Fuel Consumption, 2006; Level: National and Regional Data; Row: End Uses; Column: Energy Sources, including Net Electricity; Unit: Trillion Btu. Distillate Fuel Oil Coal Net Residual and LPG and (excluding Coal End Use Total Electricity(a) Fuel Oil Diesel Fuel(b) Natural Gas(c) NGL(d) Coke and Breeze) Other(e) Total United States TOTAL FUEL CONSUMPTION 15,658 2,850 251 129 5,512 79 1,016 5,820 Indirect Uses-Boiler Fue -- 41 133 23 2,119 8 547 -- Conventional Boiler Use 41 71 17 1,281 8 129 CHP and/or Cogeneration Process 0 62 6 838 1 417 Direct Uses-Total Process -- 2,244 62 52 2,788 39 412 -- Process Heating -- 346 59 19 2,487 32 345 -- Process Cooling and Refrigeration -- 206 * 1 32 * * -- Machine Drive

414

Level: National Data; Row: End Uses within NAICS Codes; Column: Energy Sources, including Net Electricity;  

U.S. Energy Information Administration (EIA) Indexed Site

2 End Uses of Fuel Consumption, 2006; 2 End Uses of Fuel Consumption, 2006; Level: National Data; Row: End Uses within NAICS Codes; Column: Energy Sources, including Net Electricity; Unit: Trillion Btu. Distillate Fuel Oil Coal NAICS Net Residual and LPG and (excluding Coal Code(a) End Use Total Electricity(b) Fuel Oil Diesel Fuel(c) Natural Gas(d) NGL(e) Coke and Breeze) Other(f) Total United States 311 - 339 ALL MANUFACTURING INDUSTRIES TOTAL FUEL CONSUMPTION 15,658 2,850 251 129 5,512 79 1,016 5,820 Indirect Uses-Boiler Fuel -- 41 133 23 2,119 8 547 -- Conventional Boiler Use -- 41 71 17 1,281 8 129 -- CHP and/or Cogeneration Process -- -- 62 6 838 1 417 -- Direct Uses-Total Process -- 2,244 62 52 2,788 39 412 -- Process Heating -- 346 59 19 2,487

415

Level: National and Regional Data; Row: End Uses; Column: Energy Sources, including Net Demand for Electricity;  

U.S. Energy Information Administration (EIA) Indexed Site

Next MECS will be conducted in 2010 Table 5.8 End Uses of Fuel Consumption, 2006; Level: National and Regional Data; Row: End Uses; Column: Energy Sources, including Net Demand for Electricity; Unit: Trillion Btu. Distillate Fuel Oil Coal Net Demand Residual and LPG and (excluding Coal End Use for Electricity(a) Fuel Oil Diesel Fuel(b) Natural Gas(c) NGL(d) Coke and Breeze) Total United States TOTAL FUEL CONSUMPTION 3,335 251 129 5,512 79 1,016 Indirect Uses-Boiler Fuel 84 133 23 2,119 8 547 Conventional Boiler Use 84 71 17 1,281 8 129 CHP and/or Cogeneration Process 0 62 6 838 1 417 Direct Uses-Total Process 2,639 62 52 2,788 39 412 Process Heating 379 59 19 2,487 32 345 Process Cooling and Refrigeration

416

Level: National Data; Row: End Uses within NAICS Codes; Column: Energy Sources, including Net Electricity;  

U.S. Energy Information Administration (EIA) Indexed Site

1 End Uses of Fuel Consumption, 2006; 1 End Uses of Fuel Consumption, 2006; Level: National Data; Row: End Uses within NAICS Codes; Column: Energy Sources, including Net Electricity; Unit: Physical Units or Btu. Distillate Coal Fuel Oil (excluding Coal Net Residual and Natural Gas(d) LPG and Coke and Breeze) NAICS Total Electricity(b) Fuel Oil Diesel Fuel(c) (billion NGL(e) (million Other(f) Code(a) End Use (trillion Btu) (million kWh) (million bbl) (million bbl) cu ft) (million bbl) short tons) (trillion Btu) Total United States 311 - 339 ALL MANUFACTURING INDUSTRIES TOTAL FUEL CONSUMPTION 15,658 835,382 40 22 5,357 21 46 5,820 Indirect Uses-Boiler Fuel -- 12,109 21 4 2,059 2 25 -- Conventional Boiler Use -- 12,109 11 3 1,245 2 6 -- CHP and/or Cogeneration Process

417

Theory, design, and operation of liquid metal fast breeder reactors, including operational health physics  

SciTech Connect

A comprehensive evaluation was conducted of the radiation protection practices and programs at prototype LMFBRs with long operational experience. Installations evaluated were the Fast Flux Test Facility (FFTF), Richland, Washington; Experimental Breeder Reactor II (EBR-II), Idaho Falls, Idaho; Prototype Fast Reactor (PFR) Dounreay, Scotland; Phenix, Marcoule, France; and Kompakte Natriumgekuhlte Kernreak Toranlange (KNK II), Karlsruhe, Federal Republic of Germany. The evaluation included external and internal exposure control, respiratory protection procedures, radiation surveillance practices, radioactive waste management, and engineering controls for confining radiation contamination. The theory, design, and operating experience at LMFBRs is described. Aspects of LMFBR health physics different from the LWR experience in the United States are identified. Suggestions are made for modifications to the NRC Standard Review Plan based on the differences.

Adams, S.R.

1985-10-01T23:59:59.000Z

418

Including the Effects of Electronic Excitations and Electron-Phonon Coupling in Cascade Simulations  

SciTech Connect

Radiation damage has traditionally been modeled using cascade simulations however such simulations generally neglect the effects of electron-ion interactions, which may be significant in high energy cascades. A model has been developed which includes the effects of electronic stopping and electron-phonon coupling in Molecular Dynamics simulations by means of an inhomogeneous Langevin thermostat. The energy lost by the atoms to electronic excitations is gained by the electronic system and the energy evolution of the electronic system is modeled by the heat diffusion equation. Energy is exchanged between the electronic system and the atoms in the Molecular Dynamics simulation by means of a Langevin thermostat, the temperature of which is the local electronic temperature. The model is applied to a 10 keV cascade simulation for Fe. (authors)

Duffy, Dorothy [Physics and Astronomy, UCL, London (United Kingdom)]|[EURATOM/UKAEA Fusion Association, Culham Science Centre, Oxfordshire (United Kingdom); Rutherford, Alexis [Physics and Astronomy, UCL, London (United Kingdom)

2008-07-01T23:59:59.000Z

419

Dispersion in a thermal plasma including arbitrary degeneracy and quantum recoil  

Science Conference Proceedings (OSTI)

The longitudinal response function for a thermal electron gas is calculated including two quantum effects exactly, degeneracy, and the quantum recoil. The Fermi-Dirac distribution is expanded in powers of a parameter that is small in the nondegenerate limit and the response function is evaluated in terms of the conventional plasma dispersion function to arbitrary order in this parameter. The infinite sum is performed in terms of polylogarithms in the long-wavelength and quasistatic limits, giving results that apply for arbitrary degeneracy. The results are applied to the dispersion relations for Langmuir waves and to screening, reproducing known results in the nondegenerate and completely degenerate limits, and generalizing them to arbitrary degeneracy.

Melrose, D. B. [School of Physics, University of Sydney, New South Wales 2006 (Australia); Mushtaq, A. [School of Physics, University of Sydney, New South Wales 2006 (Australia); Theoretical Plasma Physics Division, PINSTECH, Nilore, 44000 Islamabad (Pakistan)

2010-11-15T23:59:59.000Z

420

Residential sidewall insulation case histories, including experiences and problems in the field application of loose fill  

SciTech Connect

An unbonded fiberglass loose-fill insulation was selected for this sidewall application study. The insert tube technique is described and the parameters that affect pneumatic application of the product are identified. The initial evaluation was conducted in the laboratory and included density and thermal testing. The laboratory results were then utilized in field studies. Ten homes with no sidewall insulation were retrofitted. Thermographic scans of sidewalls before and after retrofit confirmed the predicted reductions in heat loss based on calculation techniques given in the ASHRAE Handbook of Fundamentals. The improvement was further confirmed by comparing utility bills. Typical problems that occur while preparing a house for sidewall retrofit are discussed. The simple payback for typical houses is presented. Good correlation is shown between laboratory test results and field performance. Test data indicate that the application procedure used gave an effective R-value per product claim.

Infante, L.J.; Aller, P.F.; Fay, R.E.

1983-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "include hotels motels" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Engine including hydraulically actuated valvetrain and method of valve overlap control  

DOE Patents (OSTI)

An exhaust valve control method may include displacing an exhaust valve in communication with the combustion chamber of an engine to an open position using a hydraulic exhaust valve actuation system and returning the exhaust valve to a closed position using the hydraulic exhaust valve actuation assembly. During closing, the exhaust valve may be displaced for a first duration from the open position to an intermediate closing position at a first velocity by operating the hydraulic exhaust valve actuation assembly in a first mode. The exhaust valve may be displaced for a second duration greater than the first duration from the intermediate closing position to a fully closed position at a second velocity at least eighty percent less than the first velocity by operating the hydraulic exhaust valve actuation assembly in a second mode.

Cowgill, Joel (White Lake, MI)

2012-05-08T23:59:59.000Z

422

Flexible barrier film, method of forming same, and organic electronic device including same  

DOE Patents (OSTI)

A flexible barrier film has a thickness of from greater than zero to less than 5,000 nanometers and a water vapor transmission rate of no more than 1.times.10.sup.-2 g/m.sup.2/day at 22.degree. C. and 47% relative humidity. The flexible barrier film is formed from a composition, which comprises a multi-functional acrylate. The composition further comprises the reaction product of an alkoxy-functional organometallic compound and an alkoxy-functional organosilicon compound. A method of forming the flexible barrier film includes the steps of disposing the composition on a substrate and curing the composition to form the flexible barrier film. The flexible barrier film may be utilized in organic electronic devices.

Blizzard, John; Tonge, James Steven; Weidner, William Kenneth

2013-03-26T23:59:59.000Z

423

A high liquid yield process for retorting various organic materials including oil shale  

DOE Patents (OSTI)

This invention is a continuous retorting process for various high molecular weight organic materials, including oil shale, that yields an enhanced output of liquid product. The organic material, mineral matter, and an acidic catalyst, that appreciably adsorbs alkenes on surface sites at prescribed temperatures, are mixed and introduced into a pyrolyzer. A circulating stream of olefin enriched pyrolysis gas is continuously swept through the organic material and catalyst, whereupon, as the result of pyrolysis, the enhanced liquid product output is provided. Mixed spent organic material, mineral matter, and cool catalyst are continuously withdrawn from the pyrolyzer. Combustion of the spent organic material and mineral matter serves to reheat the catalyst. Olefin depleted pyrolysis gas, from the pyrolyzer, is enriched in olefins and recycled into the pyrolyzer. The reheated acidic catalyst is separated from the mineral matter and again mixed with fresh organic material, to maintain the continuously cyclic process. 2 figs.

Coburn, T.T.

1988-07-26T23:59:59.000Z

424

High liquid yield process for retorting various organic materials including oil shale  

DOE Patents (OSTI)

This invention is a continuous retorting process for various high molecular weight organic materials, including oil shale, that yields an enhanced output of liquid product. The organic material, mineral matter, and an acidic catalyst, that appreciably adsorbs alkenes on surface sites at prescribed temperatures, are mixed and introduced into a pyrolyzer. A circulating stream of olefin enriched pyrolysis gas is continuously swept through the organic material and catalyst, whereupon, as the result of pyrolysis, the enhanced liquid product output is provided. Mixed spent organic material, mineral matter, and cool catalyst are continuously withdrawn from the pyrolyzer. Combustion of the spent organic material and mineral matter serves to reheat the catalyst. Olefin depleted pyrolysis gas, from the pyrolyzer, is enriched in olefins and recycled into the pyrolyzer. The reheated acidic catalyst is separated from the mineral matter and again mixed with fresh organic material, to maintain the continuously cyclic process.

Coburn, Thomas T. (Livermore, CA)

1990-01-01T23:59:59.000Z

425

Estimating parameters of coalescing compact binaries with a detector network including LIGO Australia  

E-Print Network (OSTI)

One of the goals of gravitational-wave astronomy is simultaneous detection of gravitational-wave signals from merging compact-object binaries and the electromagnetic transients from these mergers. With the next generation of advanced ground-based gravitational wave detectors under construction, we examine the benefits of the proposed extension of the detector network to include a fourth site in Australia in addition to the network of Hanford, Livingston and Cascina sites. Using Bayesian parameter-estimation analyses of simulated gravitational-wave signals from a range of coalescing-binary locations and orientations, we study the improvement in parameter estimation. We find that an Australian detector can break degeneracies in several parameters; in particular, the localization of the source on the sky is improved by a factor of ~4, with more modest improvements in distance and binary inclination estimates. This enhanced ability to localize sources on the sky will be crucial in any search for electromagnetic c...

Aylott, Benjamin; Kalogera, Vassiliki; Mandel, Ilya; Raymond, Vivien; Rodriguez, Carl; van der Sluys, Marc; Vecchio, Alberto; Veitch, John

2011-01-01T23:59:59.000Z

426

The Food Crises: A quantitative model of food prices including speculators and ethanol conversion  

E-Print Network (OSTI)

Recent increases in basic food prices are severely impacting vulnerable populations worldwide. Proposed causes such as shortages of grain due to adverse weather, increasing meat consumption in China and India, conversion of corn to ethanol in the US, and investor speculation on commodity markets lead to widely differing implications for policy. A lack of clarity about which factors are responsible reinforces policy inaction. Here, for the first time, we construct a dynamic model that quantitatively agrees with food prices. The results show that the dominant causes of price increases are investor speculation and ethanol conversion. Models that just treat supply and demand are not consistent with the actual price dynamics. The two sharp peaks in 2007/2008 and 2010/2011 are specifically due to investor speculation, while an underlying upward trend is due to increasing demand from ethanol conversion. The model includes investor trend following as well as shifting between commodities, equities and bonds to take ad...

Lagi, Marco; Bertrand, Karla Z; Bar-Yam, Yaneer

2011-01-01T23:59:59.000Z

427

Dye laser amplifier including a low turbulence, stagnation-free dye flow configuration  

DOE Patents (OSTI)

A large (high flow rate) dye laser amplifier in which a continuous replenished supply of dye is excited by a first light beam, specifically a copper vapor laser beam, in order to amplify the intensity of a second different light beam, specifically a dye beam, passing through the dye is disclosed herein. This amplifier includes a dye cell defining a dye chamber through which a continuous stream of dye is caused to pass at a flow rate of for example 30 gallons/minute, a specifically designed support vessel for containing the dye cell and a screen device for insuring that the dye stream passes into the dye cell in a substantially turbulent free, stagnation-free manner.

Davin, James (Gilroy, CA)

1992-01-01T23:59:59.000Z

428

Nonleptonic two-body B decays including axial-vector mesons in the final state  

SciTech Connect

We present a systematic study of exclusive charmless nonleptonic two-body B decays including axial-vector mesons in the final state. We calculate branching ratios of B{yields}PA, VA, and AA decays, where A, V, and P denote an axial vector, a vector, and a pseudoscalar meson, respectively. We assume a naive factorization hypothesis and use the improved version of the nonrelativistic Isgur-Scora-Grinstein-Wise quark model for form factors in B{yields}A transitions. We include contributions that arise from the effective {delta}B=1 weak Hamiltonian H{sub eff}. The respective factorized amplitudes of these decays are explicitly shown and their penguin contributions are classified. We find that decays B{sup -}{yields}a{sub 1}{sup 0}{pi}{sup -}, B{sup 0}{yields}a{sub 1}{sup {+-}}{pi}{sup {+-}}, B{sup -}{yields}a{sub 1}{sup -}K{sup 0}, B{sup 0}{yields}a{sub 1}{sup +}K{sup -}, B{sup 0}{yields}f{sub 1}K{sup 0}, B{sup -}{yields}f{sub 1}K{sup -}, B{sup -}{yields}K{sub 1}{sup -}(1400){eta}{sup (')}, B{sup -}{yields}b{sub 1}{sup -}K{sup 0}, and B{sup 0}{yields}b{sub 1}{sup +}{pi}{sup -}(K{sup -}) have branching ratios of the order of 10{sup -5}. We also study the dependence of branching ratios for B{yields}K{sub 1}P(V,A) decays [K{sub 1}=K{sub 1}(1270), K{sub 1}(1400)] with respect to the mixing angle between K{sub 1A} and K{sub 1B}.

Calderon, G.; Munoz, J. H.; Vera, C. E. [Facultad de Ingenieria Mecanica y Electrica, Universidad Autonoma de Coahuila, CP 27000, Torreon, Coahuila (Mexico); Departamento de Fisica, Universidad del Tolima, Apartado Aereo 546, Ibague (Colombia)

2007-11-01T23:59:59.000Z

429

Including realistic tidal deformations in binary black-hole initial data  

E-Print Network (OSTI)

A shortcoming of current binary black-hole initial data is the generation of spurious gravitational radiation, so-called junk radiation, when they are evolved. This problem is a consequence of an oversimplified modeling of the binary's physics in the initial data. Since junk radiation is not astrophysically realistic, it contaminates the actual waveforms of interest and poses a numerical nuisance. The work here presents a further step towards mitigating and understanding the origin of this issue, by incorporating post-Newtonian results in the construction of constraint-satisfying binary black-hole initial data. Here we focus on including realistic tidal deformations of the black holes in the initial data, by building on the method of superposing suitably chosen black hole metrics to compute the conformal data. We describe the details of our initial data for an equal-mass and nonspinning binary, compute the subsequent relaxation of horizon quantities in evolutions, and quantify the amount of junk radiation that is generated. These results are contrasted with those obtained with the most common choice of conformally flat (CF) initial data, as well as superposed Kerr-Schild (SKS) initial data. We find that when realistic tidal deformations are included, the early transients in the horizon geometries are significantly reduced, along with smaller deviations in the relaxed black hole masses and spins from their starting values. Likewise, the junk radiation content in the $l=2$ modes is reduced by a factor of $\\sim$1.7 relative to CF initial data, but only by a factor of $\\sim$1.2 relative to SKS initial data. More prominently, the junk radiation content in the $3\\leq l\\leq8$ modes is reduced by a factor of $\\sim$5 relative to CF initial data, and by a factor of $\\sim$2.4 relative to SKS initial data.

Tony Chu

2013-10-29T23:59:59.000Z

430

RDI's Wisdom Way Solar Village Final Report: Includes Utility Bill Analysis of Occupied Homes  

SciTech Connect

In 2010, Rural Development, Inc. (RDI) completed construction of Wisdom Way Solar Village (WWSV), a community of ten duplexes (20 homes) in Greenfield, MA. RDI was committed to very low energy use from the beginning of the design process throughout construction. Key features include: 1. Careful site plan so that all homes have solar access (for active and passive); 2. Cellulose insulation providing R-40 walls, R-50 ceiling, and R-40 floors; 3. Triple-pane windows; 4. Airtight construction (~0.1 CFM50/ft2 enclosure area); 5. Solar water heating systems with tankless, gas, auxiliary heaters; 6. PV systems (2.8 or 3.4kWSTC); 7. 2-4 bedrooms, 1,100-1,700 ft2. The design heating loads in the homes were so small that each home is heated with a single, sealed-combustion, natural gas room heater. The cost savings from the simple HVAC systems made possible the tremendous investments in the homes' envelopes. The Consortium for Advanced Residential Buildings (CARB) monitored temperatures and comfort in several homes during the winter of 2009-2010. In the Spring of 2011, CARB obtained utility bill information from 13 occupied homes. Because of efficient lights, appliances, and conscientious home occupants, the energy generated by the solar electric systems exceeded the electric energy used in most homes. Most homes, in fact, had a net credit from the electric utility over the course of a year. On the natural gas side, total gas costs averaged $377 per year (for heating, water heating, cooking, and clothes drying). Total energy costs were even less - $337 per year, including all utility fees. The highest annual energy bill for any home evaluated was $458; the lowest was $171.

Robb Aldrich, Steven Winter Associates

2011-07-01T23:59:59.000Z

431

Multimedia Resources, including the CMS Eye, from the Compact Muon Solenoid (CMS) Experiment at CERN  

DOE Data Explorer (OSTI)

The Compact Muon Solenoid (CMS) experiment is one of two large general-purpose particle physics detectors built on the proton-proton Large Hadron Collider (LHC) at CERN in Switzerland and France. The CMS detector is located in an underground cavern at Cessy in France. The CMS detector will study many aspects of proton collisions at 14 TeV, the center-of-mass energy of the LHC particle accelerator. [from http://en.wikipedia.org/wiki/Compact_Muon_Solenoid]

The US CMS collaboration, with 48 institutions, 420 Ph.D. physicists, over 100 graduate students, and nearly 200 engineers, technicians, and computer scientists is the largest national group in the CMS collaboration. US groups have made significant contributions to nearly every aspect of the detector throughout all phases including construction, installation and preparation for data-taking. The US collaboration also made major contributions to the construction and operation of the computing facilities needed to analyze the unprecedented amount of data to be generated by CMS. This work includes the software that allows physicists to operate the CMS detector, reconstruct the data, analyze it and extract new physics.

The CMS media website from CERN provides images, videos, presentations, and the CMS Eye, a system of webcams looking into the underground cavern at Cessy, into the control room, and even out of the window of the control room at the village of Cessy and the Jura Mountains. Many event displays are available in the image collections, as well as the CMS Photo Book covering 1998 2008 when CMS was being assembled, installed, and commissioned.

US-LHC and the International CMS Collaboration

432

Expanded rock blast modeling capabilities of DMC{_}BLAST, including buffer blasting  

SciTech Connect

A discrete element computer program named DMC{_}BLAST (Distinct Motion Code) has been under development since 1987 for modeling rock blasting. This program employs explicit time integration and uses spherical or cylindrical elements that are represented as circles in 2-D. DMC{_}BLAST calculations compare favorably with data from actual bench blasts. The blast modeling capabilities of DMC{_}BLAST have been expanded to include independently dipping geologic layers, top surface, bottom surface and pit floor. The pit can also now be defined using coordinates based on the toe of the bench. A method for modeling decked explosives has been developed which allows accurate treatment of the inert materials (stemming) in the explosive column and approximate treatment of different explosives in the same blasthole. A DMC{_}BLAST user can specify decking through a specific geologic layer with either inert material or a different explosive. Another new feature of DMC{_}BLAST is specification of an uplift angle which is the angle between the normal to the blasthole and a vector defining the direction of explosive loading on particles adjacent to the blasthole. A buffer (choke) blast capability has been added for situations where previously blasted material is adjacent to the free face of the bench preventing any significant lateral motion during the blast.

Preece, D.S. [Sandia National Labs., Albuquerque, NM (United States); Tidman, J.P.; Chung, S.H. [ICI Explosives (Canada)

1996-12-31T23:59:59.000Z

433

Casting Apparatus Including A Gas Driven Molten Metal Injector And Method  

DOE Patents (OSTI)

The casting apparatus (50) includes a holding vessel (10) for containing a supply of molten metal (12) and a casting mold (52) located above the holding vessel (10) and having a casting cavity (54). A molten metal injector (14) extends into the holding vessel (10) and is at least partially immersed in the molten metal (12) in the holding vessel (10). The molten metal injector (14) is in fluid communication with the casting cavity (54). The molten metal injector (14) has an injector body (16) defining an inlet opening (24) for receiving molten metal into the injector body (16). A gas pressurization source (38) is in fluid communication with the injector body (16) for cyclically pressurizing the injector body (16) and inducing molten metal to flow from the injector body (16) to the casting cavity (54). An inlet valve (42) is located in the inlet opening (24) in the injector body (16) for filling molten metal into the injector body (16). The inlet valve (42) is configured to prevent outflow of molten metal from the injector body (16) during pressurization and permit inflow of molten metal into the injector body (16) after pressurization. The inlet valve (42) has an inlet valve actuator (44) located above the surface of the supply of molten metal (12) and is operatively connected to the inlet valve (42) for operating the inlet valve (42) between open and closed positions.

Meyer, Thomas N. (Murrysville, PA)

2004-06-01T23:59:59.000Z

434

Funding for state, city, and county governments in the state includes:  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

MT MT Montana Total Sum City, County, and SEO Allocations All $13,971,000 MT Montana State Energy Office $9,593,500 MT Anaconda-Deer Lodge City $50,000 MT Billings City $1,003,000 MT Bozeman City $175,500 MT Butte-Silver Bow City $138,700 MT Great Falls City $570,100 MT Havre City $50,000 MT Helena City $138,600 MT Kalispell City $96,700 MT Miles City City $50,000 MT Missoula City $680,400 MT Cascade County $94,400 MT Flathead County $274,200 MT Gallatin County $198,700 MT Lake County $119,500 MT Lewis and Clark County $120,400 MT Lincoln County $80,000 MT Missoula County $151,000 MT Park County $67,100 MT Ravalli County $167,400 MT Yellowstone County $151,800 In addition, today's announcement includes funding for the following Tribal

435

Funding for state, city, and county governments in the state includes:  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

NE Nebraska Total Sum City, County, and SEO Allocations NE Nebraska Total Sum City, County, and SEO Allocations All $18,810,300 NE Nebraska State Energy Office $9,593,500 NE Bellevue City $194,200 NE Fremont City $106,400 NE Grand Island City $199,000 NE Hastings City $109,900 NE Kearney City $131,100 NE Lincoln City $2,401,000 NE Norfolk City $101,500 NE North Platte City $105,300 NE Omaha City $4,331,500 NE Papillion City $91,300 NE Cass County $99,900 NE Dakota County $87,300 NE Dawson County $106,300 NE Douglas County $255,800 NE Gage County $98,000 NE Lancaster County $110,300 NE Platte County $139,200 NE Sarpy County $312,600 NE Saunders County $80,600 NE Scotts Bluff County $155,600 In addition, today's announcement includes funding for the following Tribal

436

Funding for state, city, and county governments in the state includes:  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

NM New Mexico Total Sum City, County, and SEO NM New Mexico Total Sum City, County, and SEO Allocations All $20,608,300 NM New Mexico State Energy Office $9,593,500 NM Alamogordo City $147,700 NM Albuquerque City $5,051,200 NM Carlsbad City $107,800 NM Clovis City $139,800 NM Farmington City $191,800 NM Hobbs City $128,700 NM Las Cruces City $888,000 NM Rio Rancho City $697,000 NM Roswell City $195,500 NM Santa Fe City $781,600 NM Bernalillo County $459,500 NM Dona Ana County $446,900 NM Grant County $126,400 NM McKinley County $299,600 NM Rio Arriba County $166,500 NM San Juan County $329,400 NM Sandoval County $169,500 NM Santa Fe County $264,000 NM Taos County $134,100 NM Valencia County $289,800 In addition, today's announcement includes funding for the following Tribal

437

Funding for state, city, and county governments in the state includes:  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

NV NV Nevada Total Sum City, County, and SEO Allocations All $31,983,500 NV Nevada State Energy Office $9,593,500 NV Boulder City City $61,600 NV Carson City City $538,900 NV Elko City $76,500 NV Fernley City $52,000 NV Henderson City $2,237,000 NV Las Vegas City $5,449,200 NV Mesquite City $69,900 NV North Las Vegas City $1,907,400 NV Reno City $2,142,800 NV Sparks City $840,000 NV Churchill County $104,900 NV Clark County $7,663,500 NV Douglas County $195,000 NV Elko County $123,600 NV Humboldt County $75,600 NV Lyon County $165,200 NV Nye County $185,700 NV Pershing County $50,000 NV Washoe County $401,200 NV White Pine County $50,000 In addition, today's announcement includes funding for the following Tribal

438

cDNA encoding a polypeptide including a hev ein sequence  

DOE Patents (OSTI)

A cDNA clone (HEV1) encoding hevein was isolated via polymerase chain reaction (PCR) using mixed oligonucleotides corresponding to two regions of hevein as primers and a Hevea brasiliensis latex cDNA library as a template. HEV1 is 1018 nucleotides long and includes an open reading frame of 204 amino acids. The deduced amino acid sequence contains a putative signal sequence of 17 amino acid residues followed by a 187 amino acid polypeptide. The amino-terminal region (43 amino acids) is identical to hevein and shows homology to several chitin-binding proteins and to the amino-termini of wound-induced genes in potato and poplar. The carboxyl-terminal portion of the polypeptide (144 amino acids) is 74-79% homologous to the carboxyl-terminal region of wound-inducible genes of potato. Wounding, as well as application of the plant hormones abscisic acid and ethylene, resulted in accumulation of hevein transcripts in leaves, stems and latex, but not in roots, as shown by using the cDNA as a probe. A fusion protein was produced in E. coli from the protein of the present invention and maltose binding protein produced by the E. coli.

Raikhel, Natasha V. (Okemos, MI); Broekaert, Willem F. (Dilbeek, BE); Chua, Nam-Hai (Scarsdale, NY); Kush, Anil (New York, NY)

2000-07-04T23:59:59.000Z

439

Information management for global environmental change, including the Carbon Dioxide Information Analysis Center  

Science Conference Proceedings (OSTI)

The issue of global change is international in scope. A body of international organizations oversees the worldwide coordination of research and policy initiatives. In the US the National Science and Technology Council (NSTC) was established in November of 1993 to provide coordination of science, space, and technology policies throughout the federal government. NSTC is organized into nine proposed committees. The Committee on Environmental and Natural Resources (CERN) oversees the US Department of Energy`s Global Change Research Program (USGCRP). As part of the USGCRP, the US Department of Energy`s Global Change Research Program aims to improve the understanding of Earth systems and to strengthen the scientific basis for the evaluation of policy and government action in response to potential global environmental changes. This paper examines the information and data management roles of several international and national programs, including Oak Ridge National Laboratory`s (ORNL`s) global change information programs. An emphasis will be placed on the Carbon Dioxide Information Analysis Center (CDIAC), which also serves as the World Data Center-A for Atmospheric Trace Gases.

Stoss, F.W. [Oak Ridge National Lab., TN (United States). Carbon Dioxide Information Analysis Center

1994-06-01T23:59:59.000Z

440

Magnetohydrodynamic Simulations of the Formation of Cold Fronts in Clusters of Galaxies including Heat Conduction  

E-Print Network (OSTI)

Recent Chandra observations of clusters of galaxies revealed the existence of a sharp ridge in the X-ray surface brightness where the temperature drops across the front. This front is called the cold front. We present the results of two-dimensional magnetohydrodynamic simulations of the time evolution of a dense subcluster plasma moving in a cluster of galaxies. Anisotropic heat conduction along the magnetic field lines is included. In the models without magnetic fields, the numerical results indicate that the heat conduction from the hot ambient plasma heats the cold dense plasma of the subcluster and diffuses out the cold front. When magnetic fields exist in a cluster of galaxies, however, cold fronts can be maintained because the heat conduction across the magnetic field lines is suppressed. We found that, even when the magnetic fields in a cluster of galaxies are disordered, heat conduction across the front is restricted because the magnetic field lines are stretched along the front. Numerical results reproduced the X-ray intensity distribution observed in the A3667 cluster of galaxies.

Naoki Asai; Naoya Fukuda; Ryoji Matsumoto

2004-04-07T23:59:59.000Z

Note: This page contains sample records for the topic "include hotels motels" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Solar energy collector including a weightless balloon with sun tracking means  

DOE Patents (OSTI)

A solar energy collector having a weightless balloon, the balloon including a transparent polyvinylfluoride hemisphere reinforced with a mesh of ropes secured to its outside surface, and a laminated reflector hemisphere, the inner layer being clear and aluminized on its outside surface and the outer layer being opaque, the balloon being inflated with lighter-than-air gas. A heat collection probe extends into the balloon along the focus of reflection of the reflective hemisphere for conducting coolant into and out of the balloon. The probe is mounted on apparatus for keeping the probe aligned with the sun's path, the apparatus being founded in the earth for withstanding wind pressure on the balloon. The balloon is lashed to the probe by ropes adhered to the outer surface of the balloon for withstanding wind pressures of 100 miles per hour. Preferably, the coolant is liquid sodium-potassium eutectic alloy which will not normally freeze at night in the temperate zones, and when heated to 4,000.degree. R exerts a pressure of only a few atmospheres.

Hall, Frederick F. (2452 Villaneuva Way, Mountain View, CA 94040)

1978-01-01T23:59:59.000Z

442

High accuracy power spectra including baryonic physics in dynamical Dark Energy models  

E-Print Network (OSTI)

The next generation mass probes will obtain information on non--linear power spectra P(k,z) and their evolution, allowing us to investigate the nature of Dark Energy. To exploit such data we need high precision simulations, extending at least up to scales of k\\simeq 10 h^-1 Mpc, where the effects of baryons can no longer be neglected. In this paper, we present a series of large scale hydrodynamical simulations for LCDM and dynamical Dark Energy (dDE) models, in which the equation of state parameter is z-dependent. The simulations include gas cooling, star formation and Supernovae feedback. They closely approximate the observed star formation rate and the observationally derived star/Dark Matter mass ratio in collapsed systems. Baryon dynamics cause spectral shifts exceeding 1% at k > 2-3 hMpc^-1 compared to pure n-body simulations in the LCDM simulations. This agrees with previous studies, although we find a smaller effect (~50%) on the power spectrum amplitude at higher k's. dDE exhibits similar behavior, ev...

Casarini, Luciano; Bonometto, Silvio A; Stinson, Greg S

2010-01-01T23:59:59.000Z

443

QCD Equation of State From a Chiral Hadronic Model Including Quark Degrees of Freedom  

E-Print Network (OSTI)

This work presents an effective model for strongly interacting matter and the QCD equation of state (EoS). The model includes both hadron and quark degrees of freedom and takes into account the transition of chiral symmetry restoration as well as the deconfinement phase transition. At low temperatures $T$ and baryonic densities $\\rho_B$ a hadron resonance gas is described using a SU(3)-flavor sigma-omega model and a quark phase is introduced in analogy to PNJL models for higher $T$ and $\\rho_B$. In this way, the correct asymptotic degrees of freedom are used in a wide range of $T$ and $\\rho_B$. Here, results of this model concerning the chiral and deconfinement phase transitions and thermodynamic model properties are presented. Large hadron resonance multiplicities in the transition region emphasize the importance of heavy-mass resonance states in this region and their impact on the chiral transition behavior. The resulting phase diagram of QCD matter at small chemical potentials is in line with latest lattice QCD and thermal model results.

Philip Rau; Jan Steinheimer; Stefan Schramm; Horst Stcker

2013-06-14T23:59:59.000Z

444

Estimating parameters of coalescing compact binaries with a detector network including LIGO Australia  

E-Print Network (OSTI)

One of the goals of gravitational-wave astronomy is simultaneous detection of gravitational-wave signals from merging compact-object binaries and the electromagnetic transients from these mergers. With the next generation of advanced ground-based gravitational wave detectors under construction, we examine the benefits of the proposed extension of the detector network to include a fourth site in Australia in addition to the network of Hanford, Livingston and Cascina sites. Using Bayesian parameter-estimation analyses of simulated gravitational-wave signals from a range of coalescing-binary locations and orientations, we study the improvement in parameter estimation. We find that an Australian detector can break degeneracies in several parameters; in particular, the localization of the source on the sky is improved by a factor of ~4, with more modest improvements in distance and binary inclination estimates. This enhanced ability to localize sources on the sky will be crucial in any search for electromagnetic counterparts to detected gravitational-wave signals.

Benjamin Aylott; Benjamin Farr; Vassiliki Kalogera; Ilya Mandel; Vivien Raymond; Carl Rodriguez; Marc van der Sluys; Alberto Vecchio; John Veitch

2011-06-13T23:59:59.000Z

445

Applying environmental externalities to US Clean Coal Technologies for Asia. [Including external environmental costs  

SciTech Connect

The United States is well positioned to play an expanding role in meeting the energy technology demands of the Asian Pacific Basin, including Indonesia, Thailand, and the Republic of China (ROC-Taiwan). The US Department of Energy Clean Coal Technology (CCT) Demonstration Program provides a proving ground for innovative coal-related technologies that can be applied domestically and abroad. These innovative US CCTs are expected to satisfy increasingly stringent environmental requirements while substantially improving power generation efficiencies. They should also provide distinct advantages over conventional pulverized coal-fired combustors. Finally, they are expected to be competitive with other energy options currently being considered in the region. This paper presents potential technology scenarios for Indonesia, Thailand, and the ROC-Taiwan and considers an environmental cost-benefit approach employing a newly developed method of applying environmental externalities. Results suggest that the economic benefits from increased emission control can indeed be quantified and used in cost-benefit comparisons, and that US CCTs can be very cost effective in reducing emissions.

Szpunar, C.B.; Gillette, J.L.

1993-01-01T23:59:59.000Z

446

RDI's Wisdom Way Solar Village Final Report: Includes Utility Bill Analysis of Occupied Homes  

DOE Green Energy (OSTI)

7. 2-4 bedrooms, 1,100-1,700 ft2. The design heating loads in the homes were so small that each home is heated with a single, sealed-combustion, natural gas room heater. The cost savings from the simple HVAC systems made possible the tremendous investments in the homes' envelopes. The Consortium for Advanced Residential Buildings (CARB) monitored temperatures and comfort in several homes during the winter of 2009-2010. In the Spring of 2011, CARB obtained utility bill information from 13 occupied homes. Because of efficient lights, appliances, and conscientious home occupants, the energy generated by the solar electric systems exceeded the electric energy used in most homes. Most homes, in fact, had a net credit from the electric utility over the course of a year. On the natural gas side, total gas costs averaged $377 per year (for heating, water heating, cooking, and clothes drying). Total energy costs were even less - $337 per year, including all utility fees. The highest annual energy bill for any home evaluated was $458; the lowest was $171.

Robb Aldrich, Steven Winter Associates

2011-07-01T23:59:59.000Z

447

SEARCHING FOR EXTRATERRESTRIAL INTELLIGENCE SIGNALS IN ASTRONOMICAL SPECTRA, INCLUDING EXISTING DATA  

Science Conference Proceedings (OSTI)

The main purpose of this article is to make astronomers aware that Searches for Extraterrestrial Intelligence (SETIs) can be carried out by analyzing standard astronomical spectra, including those they have already taken. Simplicity is the outstanding advantage of a search in spectra. The spectra can be analyzed by simple eye inspection or a few lines of code that uses Fourier transform software. Theory, confirmed by published experiments, shows that periodic signals in spectra can be easily generated by sending light pulses separated by constant time intervals. While part of this article, like all articles on SETIs, is highly speculative the basic physics is sound. In particular, technology now available on Earth could be used to send signals having the required energy to be detected at a target located 1000 lt-yr away. Extraterrestrial Intelligence (ETI) could use these signals to make us aware of their existence. For an ETI, the technique would also have the advantage that the signals could be detected both in spectra and searches for intensity pulses like those currently carried out on Earth.

Borra, Ermanno F., E-mail: borra@phy.ulaval.ca [Centre d'Optique, Photonique et Laser, Departement de Physique, Universite Laval, Quebec G1 K 7P4 (Canada)

2012-12-01T23:59:59.000Z

448

A Case for Including Atmospheric Thermodynamic Variables in Wind Turbine Fatigue Loading Parameter Identification  

DOE Green Energy (OSTI)

This paper makes the case for establishing efficient predictor variables for atmospheric thermodynamics that can be used to statistically correlate the fatigue accumulation seen on wind turbines. Recently, two approaches to this issue have been reported. One uses multiple linear-regression analysis to establish the relative causality between a number of predictors related to the turbulent inflow and turbine loads. The other approach, using many of the same predictors, applies the technique of principal component analysis. An examination of the ensemble of predictor variables revealed that they were all kinematic in nature; i.e., they were only related to the description of the velocity field. Boundary-layer turbulence dynamics depends upon a description of the thermal field and its interaction with the velocity distribution. We used a series of measurements taken within a multi-row wind farm to demonstrate the need to include atmospheric thermodynamic variables as well as velocity-related ones in the search for efficient turbulence loading predictors in various turbine-operating environments. Our results show that a combination of vertical stability and hub-height mean shearing stress variables meet this need over a period of 10 minutes.

Kelley, N. D.

1999-08-02T23:59:59.000Z

449

Thermoelectric material including a multiple transition metal-doped type I clathrate crystal structure  

DOE Patents (OSTI)

A thermoelectric material includes a multiple transition metal-doped type I clathrate crystal structure having the formula A.sub.8TM.sub.y.sub.1.sup.1TM.sub.y.sub.2.sup.2 . . . TM.sub.y.sub.n.sup.nM.sub.zX.sub.46-y.sub.1.sub.-y.sub.2.sub.- . . . -y.sub.n.sub.-z. In the formula, A is selected from the group consisting of barium, strontium, and europium; X is selected from the group consisting of silicon, germanium, and tin; M is selected from the group consisting of aluminum, gallium, and indium; TM.sup.1, TM.sup.2, and TM.sup.n are independently selected from the group consisting of 3d, 4d, and 5d transition metals; and y.sub.1, y.sub.2, y.sub.n and Z are actual compositions of TM.sup.1, TM.sup.2, TM.sup.n, and M, respectively. The actual compositions are based upon nominal compositions derived from the following equation: z=8q.sub.A-|.DELTA.q.sub.1|y.sub.1-|.DELTA.q.sub.2|y.sub.2- . . . -|.DELTA.q.sub.n|y.sub.n, wherein q.sub.A is a charge state of A, and wherein .DELTA.q.sub.1, .DELTA.q.sub.2, .DELTA.q.sub.n are, respectively, the nominal charge state of the first, second, and n-th TM.

Yang, Jihui (Lakeshore, CA); Shi, Xun (Troy, MI); Bai, Shengqiang (Shanghai, CN); Zhang, Wenqing (Shanghai, CN); Chen, Lidong (Shanghai, CN); Yang, Jiong (Shanghai, CN)

2012-01-17T23:59:59.000Z

450

Efficient Evaluation of Doubly Periodic Green Functions in 3D Scattering, Including Wood Anomaly Frequencies  

E-Print Network (OSTI)

We present efficient methods for computing wave scattering by diffraction gratings that exhibit two-dimensional periodicity in three dimensional (3D) space. Applications include scattering in acoustics, electromagnetics and elasticity. Our approach uses boundary-integral equations. The quasi-periodic Green function is a doubly infinite sum of scaled 3D free-space outgoing Helmholtz Green functions. Their source points are located at the nodes of a periodicity lattice of the grating. For efficient numerical computation of the lattice sum, we employ a smooth truncation. Super-algebraic convergence to the Green function is achieved as the truncation radius increases, except at frequency-wavenumber pairs at which a Rayleigh wave is at exactly grazing incidence to the grating. At these "Wood frequencies", the term in the Fourier series representation of the Green function that corresponds to the grazing Rayleigh wave acquires an infinite coefficient and the lattice sum blows up. At Wood frequencies, we modify the Green function by adding two types of terms to it. The first type adds weighted spatial shifts of the Green function to itself with singularities below the grating; this yields algebraic convergence. The second-type terms are quasi-periodic plane wave solutions of the Helmholtz equation. They reinstate (with controlled coefficients) the grazing modes, effectively eliminated by the terms of first type. These modes are needed in the Green function for guaranteeing the well-posedness of the boundary-integral equation that yields the scattered field. We apply this approach to acoustic scattering by a doubly periodic 2D grating near and at Wood frequencies and scattering by a doubly periodic array of scatterers away from Wood frequencies.

Oscar P. Bruno; Stephen P. Shipman; Catalin Turc; Stephanos Venakides

2013-07-04T23:59:59.000Z

451

Extended three-dimensional ADCIRC hydrodynamic model to include baroclinic flow and sediment transport  

E-Print Network (OSTI)

The objective of this research is to identify the circulation patterns of the water and sediment fluxes in coastal and estuarine zones, where the shoaling processes correlate with tide generating flow patterns. The research provides a better understanding of the characteristics of spatial and temporal variability of currents. An important deviation from previous research is the inclusion of the baroclinic term, which becomes very important in density driven flows. The understanding of this process provides a basis for determining how the water circulation three-dimensionally controls the hydrodynamics of the system and ultimately transports the suspended and soluble materials due to combined currents and waves. A three-dimensional circulation model is used to calculate the water circulation. The model is based on the three-dimensional (3D) version of Advanced Circulation (AD-CIRC) Hydrodynamic Model with extending the Sediment Transport module. The model is based on the finite element method on unstructured grids. The output of the hydrody-namic model is used to estimate spatial and temporal advections, dispersions and bottom shear stress for the erosion, suspension, deposition and transport of sediment. The model development includes extending the existing three-dimensional (3D) ADCIRC Model with (1) baroclinic forcing term and (2) transport module of suspended and soluble materials. The transport module covers the erosion, material suspension and deposition processes for both cohesive and non-cohesive type sediments. The inclusion of the baroclinic demonstrates the potential of over or underpredicting the total net transport of suspended cohesive sediment under influence of currents. The model provides less than 6% error of theoretical mass conservation for eroded, suspended and deposited sediment material. The inclusion of the baroclinic term in stratified water demonstrates the prevailing longshore sediment transport. It is shown that the model has an application to the transport of the cohesive sediments from the mouth of the Mississippi River along the north shore of the Gulf of Mexico towards and along the Texas coast. The model is also applicable to determine the design erosion thickness of a cap for isolating contaminated dredged material and to evaluate the appro-priate grain size of cap sediments to minimize the erosion.

Pandoe, Wahyu Widodo

2003-05-01T23:59:59.000Z

452

Ninth Biennial OMVPE Workshop: About the Sawgrass Marriott Resort  

Science Conference Proceedings (OSTI)

The extensive hotel amenities include a full-range of restaurants and shops, as well as easy access to nearby restaurants and historic St. Augustine. The Marriott

453

Amenities | Argonne National Laboratory  

NLE Websites -- All DOE Office Websites (Extended Search)

your career flourish. Amenities on-site at Argonne include Credit Union Hotel and Restaurant Cafeteria Child Care Bike Share Program Recreational Park Fitness Center Learn More...

454

ADVANCE BROCHURE Register before August 27 and save $100!  

Science Conference Proceedings (OSTI)

8' x 10' space (includes six-foot draped table; two chairs; wastebasket; standard electricity) ..... Due to the high demand of the hotel and city on Fridays and.

455

IP Report Industries.qxd  

Science Conference Proceedings (OSTI)

... The scheme used by the USPTO to associate utility patents with their proper NAICS designation includes groups of four ... 43 Hotels and restaurants ...

2013-07-25T23:59:59.000Z

456

Assumption of Risk & Release Form s t u d y a b r o a d @ o i e . g a t e c h . e d u w w w . o i e . g a t e c h . e d u / s a  

E-Print Network (OSTI)

, and economic conditions; different standards of design, safety and maintenance of utilities, including family, transportation, carrier, hotel, tour organizer, or other provider of goods or services related

Li, Mo

457

APPROXIMATE YEARLY BUDGET, 20112012 (summer, fall, winter) the table below shows an estimate of the yearly cost per person for studying in montral. all amounts are in Canadian  

E-Print Network (OSTI)

) immigration (temporary residents) 300 $ arrival from abroad (hotel, meals...) 500 $ winter clothing 800.santeetudiante.com (in french only). 9 these amounts include furniture, utilities (water, electricity, heating

Skorobogatiy, Maksim

458

Number Description Administrative  

E-Print Network (OSTI)

Public Warehousing --Including Farm ProductsSUITE HOTELS), Refrigerated Goods, Household Goods Exclude 4900 Utilities --Electric, Gas, Water, Sanitary Wholesale Trade - Durable Goods Exclude Exclude

459

TAKING A TRIP? Travel Management Contracts  

E-Print Network (OSTI)

to airline/rail reservations, hotel lodging, airport transportation, and car rentals. #12;TRAVEL MGMT, car rentals, incidentals. Improper usage examples include movies, utility bills, alcohol. Non travel

Zobin, Nahum

460

Table Definitions, Sources, and Explanatory Notes  

U.S. Energy Information Administration (EIA)

Included are such establishments as hotels, restaurants, ... For definitions of related energy terms, refer to the EIA Energy Glossary. Sources: Form ...

Note: This page contains sample records for the topic "include hotels motels" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

The Baldrige Collaborative Assessment  

Science Conference Proceedings (OSTI)

... the CEO, I have seen a tremendous resurgent energy of our ... including all preparation work, is $20,000 plus reasonable hotel accommodations for ...

2013-04-09T23:59:59.000Z

462

Definitions - U.S. Energy Information Administration (EIA)  

U.S. Energy Information Administration (EIA)

Included are such establishments as hotels, restaurants, ... For definitions of related energy terms, refer to the EIA Energy Glossary. Sources: Form ...

463

REMR bulletin. News from the repair, evaluation, maintenance, and rehabilitation research program. Volume 13, Number 2, May 1996  

SciTech Connect

Partial contents include: (1) Environmental Friendly Lubricants, (2) What`s New in Paint, and (3) Seismic Strengthening of Hotel Oakland Revisited: A Case Study.

1996-05-01T23:59:59.000Z

464

Wisconsin #include gcc  

E-Print Network (OSTI)

_time.tv_sec = current_time.tv_sec + 2; /* convert from micro to nano */ timeout_time.tv_nsec = current_time.tv_usec

Liblit, Ben

465

Hotels & Accommodation of AFC Workshop (April 2011) - Argonne...  

NLE Websites -- All DOE Office Websites (Extended Search)

Achievements Awards Patents Argonne Distinguished Fellows Professional Societies About Nuclear Energy Reactors Designed by Argonne Argonne's Nuclear Science and Technology...

466

ENERGY STAR Success Story: Loews Hotels | ENERGY STAR  

NLE Websites -- All DOE Office Websites (Extended Search)

Federal agency resources Grocery & convenience stores resources Healthcare resources Higher education resources Home-based business resources Hospitality resources Industrial...

467

ENERGY STAR Score for Hotels | ENERGY STAR Buildings & Plants  

NLE Websites -- All DOE Office Websites (Extended Search)

Manager Login Facility owners and managers Existing buildings Commercial new construction Industrial energy management Small business Service providers Service and product...

468

American Generation Y and The Hotel of 2030.  

E-Print Network (OSTI)

??The Baby Boomer generation, once the largest, most important consumer base and leader in purchasing power, is entering retirement (Sherman, 2008). Now an aging generation, (more)

Kelley, Brian

2012-01-01T23:59:59.000Z

469

DataTrends: Energy Use in Hotels | ENERGY STAR  

NLE Websites -- All DOE Office Websites (Extended Search)

manufacturing resources K-12 school resources Multifamily housing resources Restaurant resources Retail resources Senior care resources Small business resources State and...

470

Alexis Park Hotel, Las Vegas Topic Group Meeting Participants...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

distributed a meeting agenda, welcomed participants and introduced himself as the new Rail Topic Group lead and facilitator. He introduced Item I, "Existing Business";...

471

Commercial Reference Building: Large Hotel

Open Energy Info (EERE)

descriptions for whole building energy analysis using

473

Reference Buildings by Building Type: Small Hotel | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

& Publications Reference Buildings by Climate Zone and Representative City: 2A Houston, Texas Reference Buildings by Climate Zone and Representative City: 3B Los Angeles,...

474

EPA_T1542_SECTOR_HotelA  

NLE Websites -- All DOE Office Websites (Extended Search)

lighting systems, ENERGY STAR qualified compact fluorescent lights (CFLs), and light-emitting diode (LED) exit signs. > Install occupancy sensors on lighting and HVAC systems in...

475

Exploring the context : a small hotel in Key West  

E-Print Network (OSTI)

This thesis develops a personal method and approach for designing in a delicate context such as the Key West Historic District. This thesis is composed of two parts. The first part presents observations of Key West, focusing ...

VanBeuzekom, Edrick

1984-01-01T23:59:59.000Z

476

P and n-type microcrystalline semiconductor alloy material including band gap widening elements, devices utilizing same  

DOE Patents (OSTI)

An n-type microcrystalline semiconductor alloy material including a band gap widening element; a method of fabricating p-type microcrystalline semiconductor alloy material including a band gap widening element; and electronic and photovoltaic devices incorporating said n-type and p-type materials.

Guha, Subhendu (Troy, MI); Ovshinsky, Stanford R. (Bloomfield Hills, MI)

1988-10-04T23:59:59.000Z

477

Electrolytic/fuel cell bundles and systems including a current collector in communication with an electrode thereof  

DOE Patents (OSTI)

Electrolytic/fuel cell bundles and systems including such bundles include an electrically conductive current collector in communication with an anode or a cathode of each of a plurality of cells. A cross-sectional area of the current collector may vary in a direction generally parallel to a general direction of current flow through the current collector. The current collector may include a porous monolithic structure. At least one cell of the plurality of cells may include a current collector that surrounds an outer electrode of the cell and has at least six substantially planar exterior surfaces. The planar surfaces may extend along a length of the cell, and may abut against a substantially planar surface of a current collector of an adjacent cell. Methods for generating electricity and for performing electrolysis include flowing current through a conductive current collector having a varying cross-sectional area.

Hawkes, Grant L.; Herring, James S.; Stoots, Carl M.; O& #x27; Brien, James E.

2013-03-05T23:59:59.000Z

478

Why China? A study of why foreign hotel companies are rushing to develop new luxury hotels in China.  

E-Print Network (OSTI)

??Purpose: The purpose of this professional paper is to identify why China is currently the number one recipient of foreign investment from foreign multinational luxury (more)

Hardingham, Sean

2012-01-01T23:59:59.000Z

479

A TIME ACCURATE PREDICTION OF THE VISCOUS FLOW IN A TURBINE STAGE INCLUDING A ROTOR IN MOTION.  

E-Print Network (OSTI)

??AbstractA TIME ACCURATE PREDICTION OF THE VISCOUS FLOW IN A TURBINE STAGE INCLUDING A ROTOR IN MOTIONBy Akamol ShavalikulThe actual flow field in a turbine (more)

Shavalikul, Akamol

2009-01-01T23:59:59.000Z

480

Echolocation-based foraging by harbor porpoises and sperm whales, including effects of noise and acoustic propagation  

E-Print Network (OSTI)

In this thesis, I provide quantitative descriptions of toothed whale echolocation and foraging behavior, including assessment of the effects of noise on foraging behavior and the potential influence of ocean acoustic ...

DeRuiter, Stacy L

2008-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "include hotels motels" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

An Inferred Climatology of Icing Conditions Aloft, Including Supercooled Large Drops. Part II: Europe, Asia, and the Globe  

Science Conference Proceedings (OSTI)

Because of a lack of regular, direct measurements, limited information is available about the frequency and the spatial and temporal distribution of icing conditions aloft, including supercooled large drops (SLD). Research aircraft provide in ...

Ben C. Bernstein; Christine Le Bot

2009-08-01T23:59:59.000Z

482

An Inferred Climatology of Icing Conditions Aloft, Including Supercooled Large Drops. Part I: Canada and the Continental United States  

Science Conference Proceedings (OSTI)

Because of a lack of regular, direct measurements, little information is available about the frequency and spatial and temporal distribution of icing conditions aloft, including supercooled large drops (SLD). Research aircraft provide in situ ...

Ben C. Bernstein; Cory A. Wolff; Frank McDonough

2007-11-01T23:59:59.000Z

483

A Diagnostic Method for Computing the Surface Wind from the Geostrophic Wind Including the Effects of Baroclinity  

Science Conference Proceedings (OSTI)

A diagnostic procedure to compute the surface wind from the geostrophic wind including the effects of baroclinity is designed and tested. Expressions are derived to calculate the similarity functions A and B for use when only the surface ...

Maurice Danard

1988-12-01T23:59:59.000Z

484

Purchasing in PBIO: Any emergency orders must include justification as to why it is an emergency and should be  

E-Print Network (OSTI)

Purchasing in PBIO: Any emergency orders must include justification as to why it is an emergency of justification for emergency purchase in the Internal Notes area under "Review." If a shopper only, you

Arnold, Jonathan

485

UCSC EMPLOYEE HOUSING APARTMENTS APPLICATION Rental rates include: rent, refuse collection, common area utilities, groundskeeping services, and repairs and  

E-Print Network (OSTI)

UCSC EMPLOYEE HOUSING APARTMENTS APPLICATION Rental rates include: rent, refuse collection, common. Tenants pay for their own utilities (i.e., electricity, gas, water, telephone and cable services). A $750 for current rental rates): 1 bedroom 1 bdrm deluxe 2 bdrm/1 bath 2 bdrm/2 bath) If you are interested in a two

California at Santa Cruz, University of

486

Hawaii Energy Resource Overviews. Volume 4. Impact of geothermal resource development in Hawaii (including air and water quality)  

DOE Green Energy (OSTI)

The environmental consequences of natural processes in a volcanic-fumerolic region and of geothermal resource development are presented. These include acute ecological effects, toxic gas emissions during non-eruptive periods, the HGP-A geothermal well as a site-specific model, and the geothermal resources potential of Hawaii. (MHR)

Siegel, S.M.; Siegel, B.Z.

1980-06-01T23:59:59.000Z

487

Chemical transformations are essential to all living organisms--and also to the manufacture of many products including fuels,  

E-Print Network (OSTI)

interests include plasma waste gasification, plasma torches, spectroscopy, plasma medicine, and holographic2512 IEEE TRANSACTIONS ON PLASMA SCIENCE, VOL. 36, NO. 5, OCTOBER 2008 Experimental Investigation-power microwave breakdown based on measured laser breakdown observations. Comparison of 193-nm laser

Kemner, Ken

488

Chemical Spills, Releases, Explosions, Exposures, or Injuries (includes corrosive, reactive, flammable, and toxic chemicals in solid, liquid or gas form)  

E-Print Network (OSTI)

Chemical Spills, Releases, Explosions, Exposures, or Injuries (includes corrosive, reactive, flammable, and toxic chemicals in solid, liquid or gas form) EHS Contact: Kate Lumley-Sapanski (kxl3@psu apply: When to Report: · All chemical exposures or explosions requiring medical attention must

Yener, Aylin

489

UW Madison Fleet Fiscal Year 2010 Rates: Fuel, maintenance and insurance costs are included. If fuel prices exceed the budgeted  

E-Print Network (OSTI)

UW Madison Fleet Fiscal Year 2010 Rates: Fuel, maintenance and insurance costs are included. If fuel prices exceed the budgeted amount by a significant margin, the rates will be amended with a fuel surcharge at that time and the change notice will be posted in the fleet web site, rates page. Some rate

Sheridan, Jennifer

490

This book is intended for a wide readership including engineers, ap plied mathematicians, computer scientists, and graduate students who  

E-Print Network (OSTI)

Preface This book is intended for a wide readership including engineers, ap­ plied mathematicians on the Lyapunov matrix equation. The book presents different techniques for solving and ana­ lyzing the algebraic interest. The book provides easy and quick references for the solution of many engineering and mathematical

Gajic, Zoran

491

Low-rank coal research annual report, July 1, 1989--June 30, 1990 including quarterly report, April--June 1990  

SciTech Connect

Research programs in the following areas are presented: control technology and coal preparation; advance research and technology development; combustion; liquefaction; and gasification. Sixteen projects are included. Selected items have been processed separately for inclusion in the Energy Science and Technology Database.

1990-11-01T23:59:59.000Z

492

arXiv:submit/0451583[physics.gen-ph]8Apr2012 Including Nuclear Degrees of Freedom in a Lattice  

E-Print Network (OSTI)

arXiv:submit/0451583[physics.gen-ph]8Apr2012 Including Nuclear Degrees of Freedom in a Lattice and Engineering, University of Engineering and Technology. Lahore, Pakistan Abstract. Motivated by many condensed matter and nuclear systems are described initially on the same footing. Since it may be possible

Williams, Brian C.

493

National Conference of Black Physics Students 2001 Stanford University Applied Physics  

E-Print Network (OSTI)

and rooftops of several buildings including the Hyatt Regency Hotel, the Amoco Building, and the 1250 Poydras City Residences, Energy Center, LL&E Tower, Sheraton New Orleans, 1010 Common, World Trade Center New Hotel, and 1515 Poydras. Buildings that sustained heavy damage included: Texaco Center, Dominion Tower

Wechsler, Risa H.

494

Well-balanced bicharacteristic-based scheme for multilayer shallow water flows including wet/dry fronts  

Science Conference Proceedings (OSTI)

The aim of this paper is to present a new well-balanced finite volume scheme for two-dimensional multilayer shallow water flows including wet/dry fronts. The ideas, presented here for the two-layer model, can be generalized to a multilayer case in a ... Keywords: Bicharacteristics, Evolution galerkin, Finite volume method, Two-layer shallow water, Well-balance, Wet/dry front

M. Dudzinski; M. Luk?Ov-Medvid'Ov

2013-02-01T23:59:59.000Z

495

Maximum-Intensity Volumes for Fast Contouring of Lung Tumors Including Respiratory Motion in 4DCT Planning  

Science Conference Proceedings (OSTI)

Purpose: To assess the accuracy of maximum-intensity volumes (MIV) for fast contouring of lung tumors including respiratory motion. Methods and Materials: Four-dimensional computed tomography (4DCT) data of 10 patients were acquired. Maximum-intensity volumes were constructed by assigning the maximum Hounsfield unit in all CT volumes per geometric voxel to a new, synthetic volume. Gross tumor volumes (GTVs) were contoured on all CT volumes, and their union was constructed. The GTV with all its respiratory motion was contoured on the MIV as well. Union GTVs and GTVs including motion were compared visually. Furthermore, planning target volumes (PTVs) were constructed for the union of GTVs and the GTV on MIV. These PTVs were compared by centroid position, volume, geometric extent, and surface distance. Results: Visual comparison of GTVs demonstrated failure of the MIV technique for 5 of 10 patients. For adequate GTV{sub MIV}s, differences between PTVs were <1.0 mm in centroid position, 5% in volume, {+-}5 mm in geometric extent, and {+-}0.5 {+-} 2.0 mm in surface distance. These values represent the uncertainties for successful MIV contouring. Conclusion: Maximum-intensity volumes are a good first estimate for target volume definition including respiratory motion. However, it seems mandatory to validate each individual MIV by overlaying it on a movie loop displaying the 4DCT data and editing it for possible inadequate coverage of GTVs on additional 4DCT motion states.

Rietzel, Eike [Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, MA (United States); Abteilung Biophysik, Gesellschaft fuer Schwerionenforschung, Darmstadt (Germany)], E-mail: eike@rietzel.net; Liu, Arthur K.; Chen, George T.Y.; Choi, Noah C. [Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, MA (United States)

2008-07-15T23:59:59.000Z

496

DISPOSAL OF TRU WASTE FROM THE PLUTONIUM FINISHING PLANT IN PIPE OVERPACK CONTAINERS TO WIPP INCLUDING NEW SECURITY REQUIREMENTS  

Science Conference Proceedings (OSTI)

The Department of Energy is responsible for the safe management and cleanup of the DOE complex. As part of the cleanup and closure of the Plutonium Finishing Plant (PFP) located on the Hanford site, the nuclear material inventory was reviewed to determine the appropriate disposition path. Based on the nuclear material characteristics, the material was designated for stabilization and packaging for long term storage and transfer to the Savannah River Site or, a decision for discard was made. The discarded material was designated as waste material and slated for disposal to the Waste Isolation Pilot Plant (WIPP). Prior to preparing any residue wastes for disposal at the WIPP, several major activities need to be completed. As detailed a processing history as possible of the material including origin of the waste must be researched and documented. A technical basis for termination of safeguards on the material must be prepared and approved. Utilizing process knowledge and processing history, the material must be characterized, sampling requirements determined, acceptable knowledge package and waste designation completed prior to disposal. All of these activities involve several organizations including the contractor, DOE, state representatives and other regulators such as EPA. At PFP, a process has been developed for meeting the many, varied requirements and successfully used to prepare several residue waste streams including Rocky Flats incinerator ash, Hanford incinerator ash and Sand, Slag and Crucible (SS&C) material for disposal. These waste residues are packed into Pipe Overpack Containers for shipment to the WIPP.

Hopkins, A.M.; Sutter, C.; Hulse, G.; Teal, J.

2003-02-27T23:59:59.000Z

497

Geothermal Exploration and Assessment Technology Program (review), including a report of the Reservoir Engineering Technical Advisory Group  

DOE Green Energy (OSTI)

The FY 1979 Program, recommended seismic surveys in conjunction with DOE/DGE's industry coupled program in the Northern Basin and Range Province, and the objectives of the Marina del Rey conference are presented. Final reports of six committees which met to define the state-of-the-art in geothermal exploration and to recommend exploration technology development are included. These committees are: structure, stratigraphy, and igneous processes; exploration architecture; electrical methods; seismic methods; thermal methods; water/rock interaction; and reservoir engineering. (MHR)

Nielson, D.L. (ed.)

1979-12-01T23:59:59.000Z

498

Ames/Salmonella mutagenicity assay of natural and synthetic crude oils including a Fischer-Retorted Estonian shale oil  

DOE Green Energy (OSTI)

DMSO extracts of a variety of natural and synthetic crude oils were tested for genotoxic activity in the Ames/Salmonella bioassay. Both mutagenic and cytotoxic potentials are cited. Natural crude oils and their refined products and upgraded synfuels are less mutagenic than parent crude shale oils which in turn are less mutagenic than the coal derived distillate blend sample, SRC II. However, this order is not true for cytotoxicity induced by these oil samples; therefore, caution must be exercised in the assessment of their mutagenic potential without consideration of other influential factors including cytotoxicity.

Strniste, G.F.; Nickols, J.W.

1981-01-01T23:59:59.000Z

499

Level: National Data; Row: End Uses within NAICS Codes; Column: Energy Sources, including Net Demand for Electricity;  

U.S. Energy Information Administration (EIA) Indexed Site

Next MECS will be conducted in 2010 Next MECS will be conducted in 2010 Table 5.3 End Uses of Fuel Consumption, 2006; Level: National Data; Row: End Uses within NAICS Codes; Column: Energy Sources, including Net Demand for Electricity; Unit: Physical Units or Btu. Distillate Coal Fuel Oil (excluding Coal Net Demand Residual and Natural Gas(d) LPG and Coke and Breeze) NAICS for Electricity(b) Fuel Oil Diesel Fuel(c) (billion NGL(e) (million Code(a) End Use (million kWh) (million bbl) (million bbl) cu ft) (million bbl) short tons) Total United States 311 - 339 ALL MANUFACTURING INDUSTRIES TOTAL FUEL CONSUMPTION 977,338 40 22 5,357 21 46 Indirect Uses-Boiler Fuel 24,584 21 4 2,059 2 25 Conventional Boiler Use 24,584 11 3

500

Computation of Domain-Averaged Irradiance with a Simple Two-Stream Radiative Transfer Model Including Vertical Cloud Property Correlations  

NLE Websites -- All DOE Office Websites (Extended Search)

Computation of Domain-Averaged Irradiance Computation of Domain-Averaged Irradiance with a Simple Two-Stream Radiative Transfer Model Including Vertical Cloud Property Correlations S. Kato Center for Atmospheric Sciences Hampton University Hampton, Virginia Introduction Recent development of remote sensing instruments by Atmospheric Radiation Measurement (ARM?) Program provides information of spatial and temporal variability of cloud structures. However it is not clear what cloud properties are required to express complicated cloud fields in a realistic way and how to use them in a relatively simple one-dimensional (1D) radiative transfer model to compute the domain averaged irradiance. To address this issue, a simple shortwave radiative transfer model that can treat the vertical cloud optical property correlation is developed. The model is based on the gamma-weighted