Powered by Deep Web Technologies
Note: This page contains sample records for the topic "imaging instrumentation radiobiology" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Absolute instruments and perfect imaging in geometrical optics  

E-Print Network [OSTI]

Absolute instruments and perfect imaging in geometrical optics Tom´as Tyc, Lenka Herz symmetric absolute instruments that provide perfect imaging in the sense of geometrical optics. We derive to propose several new absolute instruments, in particular a lens providing a stigmatic image of an optically

Tyc, Tomas

2

THE Q/U IMAGING EXPERIMENT INSTRUMENT  

SciTech Connect (OSTI)

The Q/U Imaging ExperimenT (QUIET) is designed to measure polarization in the cosmic microwave background, targeting the imprint of inflationary gravitational waves at large angular scales({approx}1 Degree-Sign ). Between 2008 October and 2010 December, two independent receiver arrays were deployed sequentially on a 1.4 m side-fed Dragonian telescope. The polarimeters that form the focal planes use a compact design based on high electron mobility transistors (HEMTs) that provides simultaneous measurements of the Stokes parameters Q, U, and I in a single module. The 17-element Q-band polarimeter array, with a central frequency of 43.1 GHz, has the best sensitivity (69 {mu}Ks{sup 1/2}) and the lowest instrumental systematic errors ever achieved in this band, contributing to the tensor-to-scalar ratio at r < 0.1. The 84-element W-band polarimeter array has a sensitivity of 87 {mu}Ks{sup 1/2} at a central frequency of 94.5 GHz. It has the lowest systematic errors to date, contributing at r < 0.01. The two arrays together cover multipoles in the range l {approx} 25-975. These are the largest HEMT-based arrays deployed to date. This article describes the design, calibration, performance, and sources of systematic error of the instrument.

Bischoff, C.; Brizius, A.; Buder, I.; Kusaka, A.; Smith, K. M.; Bogdan, M. [Kavli Institute for Cosmological Physics, Department of Physics, Enrico Fermi Institute, The University of Chicago, Chicago, IL 60637 (United States); Chinone, Y. [High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Cleary, K.; Reeves, R. [Cahill Center for Astronomy and Astrophysics, California Institute of Technology, 1200 E. California Blvd M/C 249-17, Pasadena, CA 91125 (United States); Dumoulin, R. N.; Newburgh, L. B. [Department of Physics and Columbia Astrophysics Laboratory, Columbia University, New York, NY 10027 (United States); Monsalve, R.; Bustos, R. [Department of Physics, University of Miami, 1320 Campo Sano Drive, Coral Gables, FL 33146 (United States); Naess, S. K. [Institute of Theoretical Astrophysics, University of Oslo, P.O. Box 1029 Blindern, N-0315 Oslo (Norway); Nixon, G. [Joseph Henry Laboratories of Physics, Jadwin Hall, Princeton University, Princeton, NJ 08544 (United States); Vanderlinde, K. [Department of Physics, McGill University, 3600 Rue University, Montreal, Quebec H3A 2T8 (Canada); Wehus, I. K. [Department of Physics, University of Oslo, P.O. Box 1048 Blindern, N-0316 Oslo (Norway); Church, S. E. [Kavli Institute for Particle Astrophysics and Cosmology and Department of Physics, Stanford University, Varian Physics Building, 382 Via Pueblo Mall, Stanford, CA 94305 (United States); Davis, R.; Dickinson, C., E-mail: newburgh@princeton.edu [Jodrell Bank Centre for Astrophysics, Alan Turing Building, School of Physics and Astronomy, University of Manchester, Oxford Road, Manchester M13 9PL (United Kingdom); and others

2013-05-01T23:59:59.000Z

3

Instrumentation for parallel magnetic resonance imaging  

E-Print Network [OSTI]

of the art of parallel MR imaging. First, a low-cost desktop MR scanner was developed (2.54 cm fields-of view) at low magnetic field strengths (25 T). The performance of the prototype was verified through bench...

Brown, David Gerald

2007-04-25T23:59:59.000Z

4

Non-extensive radiobiology  

SciTech Connect (OSTI)

The expression of survival factors for radiation damaged cells is based on probabilistic assumptions and experimentally fitted for each tumor, radiation and conditions. Here we show how the simplest of these radiobiological models can be derived from the maximum entropy principle of the classical Boltzmann-Gibbs expression. We extend this derivation using the Tsallis entropy and a cutoff hypothesis, motivated by clinical observations. A generalization of the exponential, the logarithm and the product to a non-extensive framework, provides a simple formula for the survival fraction corresponding to the application of several radiation doses on a living tissue. The obtained expression shows a remarkable agreement with the experimental data found in the literature, also providing a new interpretation of some of the parameters introduced anew. It is also shown how the presented formalism may have direct application in radiotherapy treatment optimization through the definition of the potential effect difference, simply calculated between the tumour and the surrounding tissue.

Sotolongo-Grau, O.; Rodriguez-Perez, D. [UNED, Departamento de Fisica Matematica y de Fluidos (Spain); Antoranz, J. C. [UNED, Departamento de Fisica Matematica y de Fluidos (Spain); UH, Catedra de Sistemas Complejos Henri Poincare (Cuba); Sotolongo-Costa, O. [UH, Catedra de Sistemas Complejos Henri Poincare (Cuba)

2011-03-14T23:59:59.000Z

5

Instrument effects in polarized infrared images Joseph A. Shaw, MEMBER SPIE  

E-Print Network [OSTI]

Instrument effects in polarized infrared images Joseph A. Shaw, MEMBER SPIE NOAA Environmental and fric- tional heating of the polarizer mount. Our model shows that the two surfaces of a wire uncertainties less than 1%. Subject terms: infrared polarization; thermal imaging; remote sensing. Optica

Shaw, Joseph A.

6

National Radiobiology Archives distributed access programmer's guide  

SciTech Connect (OSTI)

The National Radiobiology Archives is a comprehensive effort to gather, organize, and catalog original data, representative specimens, and supporting materials related to significant radiobiology studies. This provides researchers with information for analyses which compare or combine results of these and other studies and with materials for analysis by advanced molecular biology techniques. This Programmer's Guide document describes the database access software, NRADEMO, and the subset loading script NRADEMO/MAINT/MAINTAIN, which comprise the National Laboratory Archives Distributed Access Package. The guide is intended for use by an experienced database management specialist. It contains information about the physical and logical organization of the software and data files. It also contains printouts of all the scripts and associated batch processing files. It is part of a suite of documents published by the National Radiobiology Archives.

Prather, J. C. [Linfield Coll., McMinnville, OR (United States); Smith, S. K.; Watson, C. R. [Pacific Northwest Lab., Richland, WA (United States)

1991-12-01T23:59:59.000Z

7

National Radiobiology Archives Distributed Access user's manual  

SciTech Connect (OSTI)

This User's Manual describes installation and use of the National Radiobiology Archives (NRA) Distributed Access package. The package consists of a distributed subset of information representative of the NRA databases and database access software which provide an introduction to the scope and style of the NRA Information Systems.

Watson, C.; Smith, S. (Pacific Northwest Lab., Richland, WA (United States)); Prather, J. (Linfield Coll., McMinnville, OR (United States))

1991-11-01T23:59:59.000Z

8

Radiobiological studies using gamma and x rays.  

SciTech Connect (OSTI)

There are approximately 500 self-shielded research irradiators used in various facilities throughout the U.S. These facilities use radioactive sources containing either 137Cs or 60Co for a variety of biological investigations. A report from the National Academy of Sciences[1] described the issues with security of particular radiation sources and the desire for their replacement. The participants in this effort prepared two peer-reviewed publications to document the results of radiobiological studies performed using photons from 320-kV x rays and 137Cs on cell cultures and mice. The effectiveness of X rays was shown to vary with cell type.

Potter, Charles Augustus; Longley, Susan W.; Scott, Bobby R. [Lovelace Respiratory Research Institute, Albuquerque, NM; Lin, Yong [Lovelace Respiratory Research Institute, Albuquerque, NM; Wilder, Julie [Lovelace Respiratory Research Institute, Albuquerque, NM; Hutt, Julie A. [Lovelace Respiratory Research Institute, Albuquerque, NM; Padilla, Mabel T. [Lovelace Respiratory Research Institute, Albuquerque, NM; Gott, Katherine M. [Lovelace Respiratory Research Institute, Albuquerque, NM

2013-02-01T23:59:59.000Z

9

Radiochemistry & Imaging Instrumentation | U.S. DOE Office of Science (SC)  

Office of Science (SC) Website

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear SecurityTensile Strain Switched5 IndustrialIsadore Perlman,Bios HighRadiobiology:PrincetonRPEMSC EnergyRadiochemistry

10

AXIS: An instrument for imaging Compton radiographs using the Advanced Radiography Capability on the NIF  

SciTech Connect (OSTI)

Compton radiography is an important diagnostic for Inertial Confinement Fusion (ICF), as it provides a means to measure the density and asymmetries of the DT fuel in an ICF capsule near the time of peak compression. The AXIS instrument (ARC (Advanced Radiography Capability) X-ray Imaging System) is a gated detector in development for the National Ignition Facility (NIF), and will initially be capable of recording two Compton radiographs during a single NIF shot. The principal reason for the development of AXIS is the requirement for significantly improved detection quantum efficiency (DQE) at high x-ray energies. AXIS will be the detector for Compton radiography driven by the ARC laser, which will be used to produce Bremsstrahlung X-ray backlighter sources over the range of 50 keV–200 keV for this purpose. It is expected that AXIS will be capable of recording these high-energy x-rays with a DQE several times greater than other X-ray cameras at NIF, as well as providing a much larger field of view of the imploded capsule. AXIS will therefore provide an image with larger signal-to-noise that will allow the density and distribution of the compressed DT fuel to be measured with significantly greater accuracy as ICF experiments are tuned for ignition.

Hall, G. N., E-mail: hall98@llnl.gov; Izumi, N.; Tommasini, R.; Carpenter, A. C.; Palmer, N. E.; Zacharias, R.; Felker, B.; Holder, J. P.; Allen, F. V.; Bell, P. M.; Bradley, D.; Montesanti, R.; Landen, O. L. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550 (United States)

2014-11-15T23:59:59.000Z

11

BUSCA A Telescope Instrumentation for Simultaneous Imaging in 4 Optical Bands  

E-Print Network [OSTI]

The "Bonn University Simultaneous CAmera" (BUSCA) is a CCD camera system which allows simultaneous direct imaging of the same sky area in four colors. The optics are designed for an f/8 beam and four 4Kx4K CCDs with 15m pixels covering a field of view of 12 arcmin x 12 arcmin at a 2m class telescope. In September 1998 BUSCA has seen "First Light". The instrument is based on three dichroic beam splitters which separate optical wavelength bands such (at 430nm, 540nm, 730nm) that standard astronomical intermediate-band filter systems can be used. The dichroics are made of plane-parallel glass plates mounted at an angle of 45 degrees. Astigmatism in the transmitted beams (f/8) is completely cancelled by identical plane-parallel glass plates of suitable orientation. BUSCA offers new perspectives in astronomical multicolor photometry: i) The broadband spectral properties (e.g. color indices) of astronomical objects in the optical can be determined with high reliability even in non-photometric atmospheric conditions...

Reif, K; De Boer, K S; Schmoll, J; Müller, P; Poschmann, H; Klink, G; Kohley, R; Heber, U; Mebold, U; Mueller, Ph.

1999-01-01T23:59:59.000Z

12

International radiobiology archives of long-term animal studies. I. Descriptions of participating institutions and studies  

SciTech Connect (OSTI)

This document describes archived radiobiology animal studies. Information is presented on experimental details, pathology, radioactivity, results, dosimetry, status, and animal type employed.

Gerber, G.B.; Watson, C.R.; Sugahara, T.; Okada, S.

1996-07-01T23:59:59.000Z

13

A neutron imaging device for sample alignment in a pulsed neutron scattering instrument  

SciTech Connect (OSTI)

A neutron-imaging device for alignment purposes has been tested on the INES beamline at ISIS, the pulsed neutron source of Rutherford Appleton Laboratory (U.K.). Its use, in conjunction with a set of movable jaws, turns out extremely useful for scattering application to complex samples where a precise and well-defined determination of the scattering volume is needed.

Grazzi, F.; Scherillo, A.; Zoppi, M. [Consiglio Nazionale delle Ricerche, Istituto dei Sistemi Complessi, via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy)

2009-09-15T23:59:59.000Z

14

Atmospheric Data, Images, and Animations from Lidar Instruments used by the University of Wisconsin Lidar Group  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

The Space Science and Engineering Center is a research and development center affiliated with the University of Wisconsin-Madison’s Graduate School. Its primary focus is on geophysical research and technology to enhance understanding of the atmosphere of Earth, the other planets in the Solar System, and the cosmos. SSEC develops new observing tools for spacecraft, aircraft, and ground-based platforms, and models atmospheric phenomena. The Center receives, manages and distributes huge amounts of geophysical data and develops software to visualize and manipulate these data for use by researchers and operational meteorologists all over the world.[Taken from About SSEC at http://www.ssec.wisc.edu/overview/] A huge collection of data products, images, and animations comes to the SSEC from the University of Wisconsin Lidar Group. Contents of this collection include: • An archive of thousands of Lidar images acquired before 2004 • Arctic HSRL, MMCR, PAERI, MWR, Radiosonde, and CRAS forecast data Data after May 1, 2004 • MPEG animations and Lidar Multiple Scattering Models

15

Radiobiological evaluation of new boron delivery agents for boron neutron capture therapy  

E-Print Network [OSTI]

This thesis evaluates the radiobiological effectiveness of three new boron compounds namely a boronated porphyrin (BOPP) and two liposome formulations for neutron capture therapy (BNCT). The methodology utilizes in vitro ...

Chung, Yoonsun

2008-01-01T23:59:59.000Z

16

Development, characterization, and application of a charged particle microbeam for radiobiological research  

E-Print Network [OSTI]

The goal of this work is to develop a charged-particle microbeam for use in radiobiological research at the MIT Laboratory for Accelerator Beam Applications (LABA). The purpose of this device is to precisely explore the ...

Folkert, Michael R. (Michael Ryan), 1975-

2005-01-01T23:59:59.000Z

17

Amchitka Radiobiological Program progress report, January 1979-December 1979  

SciTech Connect (OSTI)

The objective of the Amchitka Radiobiological Program for the period 1970-1979 was to determine the extent of radionuclide contamination from world-wide atmospheric fallout and from the detonation of three underground nuclear blasts on Amchitka Island. The objective is achieved, by the collection and radiological analyses of biological and environmental samples and by background radiation measurements. Leakage of radionuclides from the underground sites of the Amchitka nuclear detonations would be suspected if the contamination was significntly greater than would be expected from world fallout. An account of the program from July 1970 to December 1978 has been given in nine previous reports from the Laboratory of Radiation Ecology to the Nevada Operations Office of the US Department of Energy. This report is an account of the program for calendar year 1979. The results of analyses of the samples collected in 1979 lead to the same conclusions as in previous years; i.e., there is no evidence that the radionuclide contamination at Amchitka Island is greater than would be expected from world fallout except for a slight contamination of the Long Shot Mud Pits with tritium.

Thornberg, L.D.; Sibley, T.H.; Nakatani, R.E.

1980-07-01T23:59:59.000Z

18

REVIEW OF SCIENTIFIC INSTRUMENTS 82, 073301 (2011) Calibration of a Thomson parabola ion spectrometer and Fujifilm imaging  

E-Print Network [OSTI]

accelerator. The sensitivity of Fujifilm BAS-TR imaging plates, used as a detector in the Thomson parabola

19

Nuclear Instruments and Methods in Physics Research A 545 (2005) 427435 CYBPET: a cylindrical PET system for breast imaging  

E-Print Network [OSTI]

Nuclear Instruments and Methods in Physics Research A 545 (2005) 427­435 CYBPET: a cylindrical PET January 2005 Available online 28 March 2005 Abstract We propose a Cylindrical Breast PET (CYBPET) system of scattered photons from the other breast and the rest of the body. To compare the CYBPET with whole-body PET

Thompson, Chris

20

Exertion instruments  

E-Print Network [OSTI]

This dissertation describes the research, development and reasoning behind a family of musical instruments called Exertion Instruments. They use inline electrical generators to run a synthesizer and an amplifier while ...

Vawter, Noah (Noah Theodore)

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "imaging instrumentation radiobiology" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Radiolabeled monoclonal antibodies for imaging and therapy: Potential, problems, and prospects: Scientific highlights  

SciTech Connect (OSTI)

This meeting focused on areas of research on radiolabeled monoclonal antibodies. Topics covered included the production, purification, and fragmentation of monoclonal antibodies and immunochemistry of hybridomas; the production and the chemistry of radionuclides; the radiohalogenation and radiometal labeling techniques; the in-vivo pharmacokinetics of radiolabeled antibodies; the considerations of immunoreactivity of radiolabeled preparations; the instrumentation and imaging techniques as applied to radioimmunodetection; the radiation dosimetry in diagnostic and therapeutic use of labeled antibodies; the radioimmunoscintigraphy and radioimmunotherapy studies; and perspectives and directions for future research. Tutorial as well as scientific lectures describing the latest research data on the above topics were presented. Three workshop panels were convened on ''Methods for Determining Immunoreactivity of Radiolabeled Monoclonal Antibodies - Problems and Pitfalls,'' Radiobiological and Dosimetric Considerations for Immunotherapy with Labeled Antibodies,'' and ''The Human Anti-Mouse Antibody Response in Patients.''

Srivastava, S.C.; Buraggi, G.L.

1986-01-01T23:59:59.000Z

22

MAKO: a pathfinder instrument for on-sky demonstration of low-cost 350 micron imaging arrays  

E-Print Network [OSTI]

Submillimeter cameras now have up to $10^4$ pixels (SCUBA 2). The proposed CCAT 25-meter submillimeter telescope will feature a 1 degree field-of-view. Populating the focal plane at 350 microns would require more than $10^6$ photon-noise limited pixels. To ultimately achieve this scaling, simple detectors and high-density multiplexing are essential. We are addressing this long-term challenge through the development of frequency-multiplexed superconducting microresonator detector arrays. These arrays use lumped-element, direct-absorption resonators patterned from titanium nitride films. We will discuss our progress toward constructing a scalable 350 micron pathfinder instrument focusing on fabrication simplicity, multiplexing density, and ultimately a low per-pixel cost.

Swenson, Loren J; Dowell, Charles D; Eom, Byeong H; Hollister, Matthew I; Jarnot, Robert; Kovãcs, Attila; Leduc, Henry G; McKenney, Christopher M; Monroe, Ryan; Mroczkowski, Tony; Nguyen, Hien T; Zmuidzinas, Jonas; 10.1117/12.926223

2012-01-01T23:59:59.000Z

23

AFRRI (Armed Forces Radiobiology Research Institute). Annual research report, 1 October 1984-30 September 1985  

SciTech Connect (OSTI)

The Armed Forces Radiobiology Research Inst.(AFRRI) is the primary DOD facility for scientific research in the field of radiobiology and related matters. It conducts applied and basic research that is essential for the operational and medical support of the DOD. The work is carried out by five scientific departments: Behavioral sciences - Effects on ionizing radiation, chemicals, and drugs on performance. Biochemistry - Elucidation of mechanisms of injury, repair, and protection from the effects of ionizing radiation alone or in combination with other agents; development of improved methods to detect and quantify the severity of radiation injury. Experimental Hematology - Investigation of radiation injury of bone marrow; development of therapy for damage from intermediate radiation doses; determination and treatment of injuries caused by combined effects of radiation, blast, and burns. Physiology - Research on cellular, tissue, and whole-animal models to determine physiological and biophysical changes resulting from radiation either alone or in combination with drugs and other chemicals. and Radiation Sciences - Operation, maintenance, and quality control of all AFRRI radiation sources, radiation dosimetry and estimation of tissue doses at various depths in different kinds if tissues; development and use of nuclear medicine and magnetic spectroscopic techniques for determining radiation damage in animals and model systems.

Not Available

1985-09-30T23:59:59.000Z

24

ARM - Instruments  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary)morphinanInformation InInformation InExplosionAnnouncements MediagovCampaignsListgovInstrumentsLocation

25

ARM - Instruments  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth (AOD) by Microtops Atmospheric OpticalExperiment (VORTEX)govCampaignsWintergovInstrumentsAirborne

26

Comp Plan: A computer program to generate dose and radiobiological metrics from dose-volume histogram files  

SciTech Connect (OSTI)

Treatment planning studies often require the calculation of a large number of dose and radiobiological metrics. To streamline these calculations, a computer program called Comp Plan was developed using MATLAB. Comp Plan calculates common metrics, including equivalent uniform dose, tumor control probability, and normal tissue complication probability from dose-volume histogram data. The dose and radiobiological metrics can be calculated for the original data or for an adjusted fraction size using the linear quadratic model. A homogeneous boost dose can be added to a given structure if desired. The final output is written to an Excel file in a format convenient for further statistical analysis. Comp Plan was verified by independent calculations. A lung treatment planning study comparing 45 plans for 7 structures using up to 6 metrics for each structure was successfully analyzed within approximately 5 minutes with Comp Plan. The code is freely available from the authors on request.

Holloway, Lois Charlotte, E-mail: lois.holloway@sswahs.nsw.gov.au [Liverpool and Macarthur Cancer Therapy Centres, Sydney (Australia); Center for Medical Radiation Physics, University of Wollongong (Australia); Institute of Medical Physics, University of Sydney (Australia); Miller, Julie-Anne [Liverpool and Macarthur Cancer Therapy Centres, Sydney (Australia); Institute of Medical Physics, University of Sydney (Australia); Kumar, Shivani [Liverpool and Macarthur Cancer Therapy Centres, Sydney (Australia); Whelan, Brendan M. [Institute of Medical Physics, University of Sydney (Australia); Vinod, Shalini K. [Liverpool and Macarthur Cancer Therapy Centres, Sydney (Australia); University of New South Wales (Australia)

2012-10-01T23:59:59.000Z

27

PRINCIPLES OF SCIENTIFIC INSTRUMENTS Spring 2012  

E-Print Network [OSTI]

/email interaction. Course requirements: Participation in class discussion, problem sets, take home final exam of exponential behavior in chem., biochem., physics: molecules vs. instruments. 6 Light absorption densitometry, energy transfer, photobleaching and single molec., image analysis. Anisotropy and molecular mobility

Sharp, Kim

28

Positron Emission Tomography Physics, Instrumentation, Data Analysis  

E-Print Network [OSTI]

1 Positron Emission Tomography Physics, Instrumentation, Data Analysis Carl K. Hoh, MD Department fast computer Filtered Back Projection Iterative Reconstruction PET Image Reconstruction #12 PET Scanner Design · Smaller individual crystal size = better spatial resolution · Physical limit

Liu, Thomas T.

29

Low activated incore instrument  

DOE Patents [OSTI]

Instrumentation for nuclear reactor head-mounted incore instrumentation systems fabricated of low nuclear cross section materials (i.e., zirconium or titanium). The instrumentation emits less radiation than that fabricated of conventional materials.

Ekeroth, Douglas E. (Delmont, PA)

1994-01-01T23:59:59.000Z

30

Low activated incore instrument  

DOE Patents [OSTI]

Instrumentation is described for nuclear reactor head-mounted incore instrumentation systems fabricated of low nuclear cross section materials (i.e., zirconium or titanium). The instrumentation emits less radiation than that fabricated of conventional materials. 9 figures.

Ekeroth, D.E.

1994-04-19T23:59:59.000Z

31

Candidate Selection Instrument  

Broader source: Energy.gov [DOE]

The candidate selection instrument is designed to take the guesswork out of selecting candidates for the various career development programs of interest. The instrument is straightforward and...

32

Evaluating musical instruments  

SciTech Connect (OSTI)

Scientific measurements of sound generation and radiation by musical instruments are surprisingly hard to correlate with the subtle and complex judgments of instrumental quality made by expert musicians.

Campbell, D. Murray

2014-04-01T23:59:59.000Z

33

The QUIET Instrument  

SciTech Connect (OSTI)

The Q/U Imaging ExperimenT (QUIET) is designed to measure polarization in the Cosmic Microwave Background, targeting the imprint of inflationary gravitational waves at large angular scales ({approx}1{sup o}). Between 2008 October and 2010 December, two independent receiver arrays were deployed sequentially on a 1.4m side-fed Dragonian telescope. The polarimeters which form the focal planes use a highly compact design based on High Electron Mobility Transistors (HEMTs) that provides simultaneous measurements of the Stokes parameters Q, U, and I in a single module. The 17-element Q-band polarimeter array, with a central frequency of 43.1 GHz, has the best sensitivity (69 {mu}Ks{sup 1/2}) and the lowest instrumental systematic errors ever achieved in this band, contributing to the tensor-to-scalar ratio at r < 0:1. The 84-element W-band polarimeter array has a sensitivity of 87 {mu}Ks{sup 1/2} at a central frequency of 94.5 GHz. It has the lowest systematic errors to date, contributing at r < 0:01. The two arrays together cover multipoles in the range {ell} {approx} 25 -- 975. These are the largest HEMT-based arrays deployed to date. This article describes the design, calibration, performance of, and sources of systematic error for the instrument.

Bischoff, C.; et al.

2012-07-01T23:59:59.000Z

34

Career Map: Instrumentation Coordinator  

Broader source: Energy.gov [DOE]

The Wind Program's Career Map provides job description information for Instrumentation Coordinator positions.

35

Imaging  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary)morphinanInformation Desert Southwest Region service area.Portaldefault Sign In About |Imaging Imaging Print

36

A very thin havar film vacuum window for heavy ions to perform radiobiology studies at the BNL Tandem  

SciTech Connect (OSTI)

Heavy ion beams from the BNL Tandem Van de Graaff accelerators will be made available for radiobiology studies on cell cultures. Beam energy losses need to be minimized both in the vacuum window and in the air in order to achieve the ranges required for the cells to be studied. This is particularly challenging for ions heavier than iron. The design is presented of a 0.4-inch diameter Havar film window that will satisfy these requirements. Films as thin as 80 microinches were successfully pressure tested. The final thickness to be used may be slightly larger to help in achieving pin hole free windows. We discuss design considerations and present pressure and vacuum test results as well as tests with heavy ion beams.

Thieberger, P.; Abendroth, H.; Alessi, J.; Cannizzo, L.; Carlson, C.; Gustavsson, A.; Minty, M.; Snydstrup, L.

2011-03-28T23:59:59.000Z

37

Imaging  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc DocumentationP-SeriesFlickr FlickrGuidedCH2MLLCBasicsScience atIanIgorIlyaBuildingImaging Print

38

Imaging  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc DocumentationP-SeriesFlickr FlickrGuidedCH2MLLCBasicsScience atIanIgorIlyaBuildingImaging

39

Intensity Frontier Instrumentation  

E-Print Network [OSTI]

This report summarizes findings of the 2013 Snowmass Community Summer Study Instrumentation Frontier's subgroup on the Intensity Frontier. This report is directed at identifying instrumentation R&D needed to support particle physics research over the coming decades at the Intensity Frontier.

S. H. Kettell; R. A. Rameika; R. S. Tschirhart

2013-09-26T23:59:59.000Z

40

Instrument Series: Spectroscopy and Diffraction XPS Imaging  

E-Print Network [OSTI]

from multiple ports where, in the future, catalysis chambers equipped with Raman and IR spectrometers electronic structure and energy level alignments Chemistry, materials science, and engineering ­ understand deposition sources, and gas manifolds on a RDC will be added Electron energy analyzer ­ provides high

Note: This page contains sample records for the topic "imaging instrumentation radiobiology" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Space Instrument Realization (ISR-5)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

5 Space Instrument Realization Providing expertise to support the design and fabrication of space-based custom instrumentation Contacts Group Leader Amy Regan Email Staff...

42

Instrument Technique Staff Assisted &  

E-Print Network [OSTI]

Nanophoton Raman 11 Raman Spectroscopy $150 $175 Newport Solar Simulator Solar Simulator $150 $175 Nicolet $175 CM Furnace Furnace $65 $120 CNT Furnace Furnace $65 $120 Desert Cryo Probe Station Probe Station will be added depending on your funding instrument or agreement. #12;Lead Furnace Furnace $65 $120 Lindberg 1

Braun, Paul

43

AC resistance measuring instrument  

DOE Patents [OSTI]

An auto-ranging AC resistance measuring instrument for remote measurement of the resistance of an electrical device or circuit connected to the instrument includes a signal generator which generates an AC excitation signal for application to a load, including the device and the transmission line, a monitoring circuit which provides a digitally encoded signal representing the voltage across the load, and a microprocessor which operates under program control to provide an auto-ranging function by which range resistance is connected in circuit with the load to limit the load voltage to an acceptable range for the instrument, and an auto-compensating function by which compensating capacitance is connected in shunt with the range resistance to compensate for the effects of line capacitance. After the auto-ranging and auto-compensation functions are complete, the microprocessor calculates the resistance of the load from the selected range resistance, the excitation signal, and the load voltage signal, and displays of the measured resistance on a digital display of the instrument. 8 figs.

Hof, P.J.

1983-10-04T23:59:59.000Z

44

SUNRISE: INSTRUMENT, MISSION, DATA, AND FIRST RESULTS  

SciTech Connect (OSTI)

The SUNRISE balloon-borne solar observatory consists of a 1 m aperture Gregory telescope, a UV filter imager, an imaging vector polarimeter, an image stabilization system, and further infrastructure. The first science flight of SUNRISE yielded high-quality data that revealed the structure, dynamics, and evolution of solar convection, oscillations, and magnetic fields at a resolution of around 100 km in the quiet Sun. After a brief description of instruments and data, the first qualitative results are presented. In contrast to earlier observations, we clearly see granulation at 214 nm. Images in Ca II H display narrow, short-lived dark intergranular lanes between the bright edges of granules. The very small-scale, mixed-polarity internetwork fields are found to be highly dynamic. A significant increase in detectable magnetic flux is found after phase-diversity-related reconstruction of polarization maps, indicating that the polarities are mixed right down to the spatial resolution limit and probably beyond.

Solanki, S. K.; Barthol, P.; Danilovic, S.; Feller, A.; Gandorfer, A.; Hirzberger, J.; Riethmueller, T. L.; Schuessler, M. [Max-Planck-Institut fuer Sonnensystemforschung, Max-Planck-Str. 2, 37191 Katlenburg-Lindau (Germany); Bonet, J. A.; Pillet, V. MartInez [Instituto de Astrofisica de Canarias, C/Via Lactea s/n, 38200 La Laguna, Tenerife (Spain); Del Toro Iniesta, J. C. [Instituto de Astrofisica de AndalucIa (CSIC), Apdo. de Correos 3004, E-18080, Granada (Spain); Domingo, V.; Palacios, J. [Grupo de AstronomIa y Ciencias del Espacio, Universidad de Valencia, E-46980, Paterna, Valencia (Spain); Knoelker, M. [High Altitude Observatory, National Center for Atmospheric Research, P.O. Box 3000, Boulder, CO 80307-3000 (United States); Gonzalez, N. Bello; Berkefeld, T.; Franz, M.; Schmidt, W. [Kiepenheuer-Institut fuer Sonnenphysik, Schoeneckstr. 6, 79104 Freiburg (Germany); Title, A. M., E-mail: solanki@mps.mpg.d [Lockheed-Martin Solar and Astrophysical Lab., Palo Alto, CA 94304 (United States)

2010-11-10T23:59:59.000Z

45

Beagle Dog Tissue Archive (previously part of National Radiobiology Archives): from the Janus Tissue Archive at Northwestern University  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

Following the advent of the atomic age, many nations have investigated the effects of radioactive exposure in animal models. Some of these investigations involved costly and unique experiments that produced tissue and data archives which are unlikely to be reproduced. In an effort to extract the value from these collections, programs have started in Japan, Europe, and America to preserve and make public the data and tissues from these studies for further investigation. The Beagle Dog Experiments, carried out at Argonne National Laboratory from 1952 to 1991 by Thomas Fritz, William Norris, and Tom Seed and supported by grants from the Atomic Energy Commission, investigated the effects of Cobalt-60 radiation on beagle dogs. Documentation from these studies is availible in pdf form. This web portal seeks to make accessible the animal tissues and study data from the Beagle Dog Experiments using data organized by Charles Watson. Use the search form to the left to look for dog data from particular experimental conditions. Click a dog number to return the full dog record. Use the dog record to find tissues of interest and make a sample tissue request. These tissue samples and the data were known until recently as the the U.S. National Radiobiology Archives (NRA) and were maintained as the United States Transuranium and Uranium Registries (USTUR) at Washington State University. Life-span studies using beagle dogs were done at the Argonne National Laboratory, University of California at Davis, Pacific Northwest National Laboratory, Inhalation Toxicology Research Institute, and the University of Utah. The results and many microscope slides from these life-span studies, totaling some 6000 dogs, are now available to researchers. A seminal work included in the Archive is The Atlas of Experimentally-Induced Neoplasia in the Beagle Dog (Watson et al, 1997).

Watson, Charles R.

46

ARM - Instrumentation Workshop 2008  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc Documentation RUC : XDC documentationgovInstrumentstsigovInstrumentswsiFacilityInstrumentation

47

Patient-Specific Dosimetry and Radiobiological Modeling of Targeted Radionuclide Therapy Grant - final report  

SciTech Connect (OSTI)

The broad, long-term objectives of this application are to 1. develop easily implementable tools for radionuclide dosimetry that can be used to predict normal organ toxicity and tumor response in targeted radionuclide therapy; and 2. to apply these tools to the analysis of clinical trial data in order to demonstrate dose-response relationships for radionuclide therapy treatment planning. The work is founded on the hypothesis that robust dose-response relationships have not been observed in targeted radionuclide therapy studies because currently available internal dosimetry methodologies are inadequate, failing to adequately account for individual variations in patient anatomy, radionuclide activity distribution/kinetics, absorbed dose-distribution, and absorbed dose-rate. To reduce development time the previously available software package, 3D-ID, one of the first dosimetry software packages to incorporate 3-D radionuclide distribution with individual patient anatomy; and the first to be applied for the comprehensive analysis of patient data, will be used as a platform to build the functionality listed above. The following specific aims are proposed to satisfy the long-term objectives stated above: 1. develop a comprehensive and validated methodology for converting one or more SPECT images of the radionuclide distribution to a 3-D representation of the cumulated activity distribution; 2. account for differences in tissue density and atomic number by incorporating an easily implementable Monte Carlo methodology for the 3-D dosimetry calculations; 3. incorporate the biologically equivalent dose (BED) and equivalent uniform dose (EUD) models to convert the spatial distribution of absorbed dose and dose-rate into equivalent single values that account for differences in dose uniformity and rate and that may be correlated with tumor response and normal organ toxicity; 4. test the hypothesis stated above by applying the resulting package to patient trials of targeted radionuclide therapy to obtain normal organ and tumor dose vs. response correlations. Completion of the aims outlined above will make it possible to perform patient-specific dosimetry that incorporates considerations likely to provide robust dose-response relationships. Such an advance will improve targeted radionuclide therapy by making it possible to adopt treatment planning methodologies.

George Sgouros, Ph.D.

2007-03-20T23:59:59.000Z

48

Evolution of infrared instrumentation  

SciTech Connect (OSTI)

The emergence of consumer-oriented infrared (IR) imaging devices is discussed. The discussion shows that the industry is presently dwindling because it does not fulfill expanding consumer needs. The features of future imaging devices are pointed out - smaller, easier to use, and easier to maintain. The challenge in the 1980s for the infrared manufacturing industry is to develop new technical innovations, smart IR imagining sensors, and consumer-oriented marketing, and produce a business/competitive industry. (MCW)

Sears, R.W.

1980-01-01T23:59:59.000Z

49

TMT Science and Instruments  

E-Print Network [OSTI]

To meet the scientific goals of the Thirty Meter Telescope Project, full diffraction-limited performance is required from the outset and hence the entire observatory is being designed, as a system, to achieve this. The preliminary design phases of the telescope and the first light adaptive optic facility are now approaching completion so that much better predictions of the system performance are possible. The telescope design and instrumentation are summarized in this presentation, with a brief description of some of the scientific programs that are foreseen.

David Crampton; Luc Simard; David Silva

2008-01-23T23:59:59.000Z

50

ARM - Site Instruments  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth (AOD) by Microtops AtmosphericApplication andAnthe Infrared LandSystemCentral FacilityInstruments SGP

51

ARM - Site Instruments  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth (AOD) by Microtops AtmosphericApplication andAnthe Infrared LandSystemCentral FacilityInstruments

52

ARM - Instrument Contacts  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary)morphinanInformation InInformation InExplosionAnnouncements MediagovCampaignsList ofgovInstrumentsContacts

53

ARM - Instrument Location Table  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary)morphinanInformation InInformation InExplosionAnnouncements MediagovCampaignsListgovInstrumentsLocation Table

54

ARM - RHUBC II Instruments  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc Documentation RUC :ProductsSCM Forcing Data DerivedInstruments Related Links RHUBC-II Home RHUBC

55

ARM - Recovery Act Instruments  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc Documentation RUC :ProductsSCM Forcing Data DerivedInstruments Related Links RelatedActRecovery

56

ARM - Site Instruments  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc Documentation RUC :ProductsSCM Forcing DataScience Questions Related Links AzoresInstruments

57

ARM - Site Instruments  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc Documentation RUC :ProductsSCM Forcing DataScience Questions RelatedInactiveInstruments NSA

58

ARM - Site Instruments  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc Documentation RUC :ProductsSCM Forcing DataScience Questions RelatedInactiveInstruments

59

ARM - Site Instruments  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc Documentation RUC :ProductsSCM Forcing DataScience QuestionsInactiveInstruments TWP Related

60

WNR Instrument Contacts  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsrucLasDelivered energy consumption byAbout Printable Version Bookmark and WindArchivesInstrument

Note: This page contains sample records for the topic "imaging instrumentation radiobiology" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

ARM - Instrument - 50rwp  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcal Documentation(AVIRIS) ProductsAirborneOctober 11, 2011 [FacilityIndiaGVAXAssociatedgovInstruments50rwp

62

Cooling the dark energy camera instrument  

SciTech Connect (OSTI)

DECam, camera for the Dark Energy Survey (DES), is undergoing general design and component testing. For an overview see DePoy, et al in these proceedings. For a description of the imager, see Cease, et al in these proceedings. The CCD instrument will be mounted at the prime focus of the CTIO Blanco 4m telescope. The instrument temperature will be 173K with a heat load of 113W. In similar applications, cooling CCD instruments at the prime focus has been accomplished by three general methods. Liquid nitrogen reservoirs have been constructed to operate in any orientation, pulse tube cryocoolers have been used when tilt angles are limited and Joule-Thompson or Stirling cryocoolers have been used with smaller heat loads. Gifford-MacMahon cooling has been used at the Cassegrain but not at the prime focus. For DES, the combined requirements of high heat load, temperature stability, low vibration, operation in any orientation, liquid nitrogen cost and limited space available led to the design of a pumped, closed loop, circulating nitrogen system. At zenith the instrument will be twelve meters above the pump/cryocooler station. This cooling system expected to have a 10,000 hour maintenance interval. This paper will describe the engineering basis including the thermal model, unbalanced forces, cooldown time, the single and two-phase flow model.

Schmitt, R.L.; Cease, H.; /Fermilab; DePoy, D.; /Ohio State U.; Diehl, H.T.; Estrada, J.; Flaugher, B.; /Fermilab; Kuhlmann, S.; /Ohio State U.; Onal, Birce; Stefanik, A.; /Fermilab

2008-06-01T23:59:59.000Z

63

Instrumentation for CTA site characterization  

E-Print Network [OSTI]

Many atmospheric and climatic criteria have to be taken into account for the selection of a suitable site for the next generation of imaging air-shower Cherenkov telescopes, the "Cherenkov Telescope Array" CTA. Such data are not available with sufficient precision or the comparability to allow for a comprehensive characterization of the proposed sites to be made. Identical cross-calibrated instruments have been developed which allow for precise comparison between sites, the cross-validation of existing data, and the ground-validation of satellite data. The site characterization work package of the CTA consortium opted to construct and deploy 9 copies of an autonomous multi-purpose weather sensor, incorporating an infrared cloud sensor a newly developed sensor for measuring the light of the night sky, and an All-Sky-Camera, the whole referred to as Autonomous Tool for Measuring Observatory Site COnditions PrEcisely (ATMOSCOPE). We present here the hardware that was combined into the ATMOSCOPE and characterize ...

Fruck, Christian; Ernenwein, Jean-Pierre; Mandát, Dušan; Schweizer, Thomas; Häfner, Dennis; Bulik, Tomasz; Cieslar, Marek; Costantini, Heide; Dominik, Michal; Ebr, Jan; Garczarczyk, Markus; Lorentz, Eckart; Pareschi, Giovanni; Pech, Miroslav; Puerto-Giménez, Irene; Teshima, Masahiro

2015-01-01T23:59:59.000Z

64

The MICE PID Instrumentation  

E-Print Network [OSTI]

The international Muon Ionization Cooling Experiment (MICE) will carry out a systematic investigation of ionization cooling of a muon beam. As the emittance measurement will be done on a particle-by-particle basis, sophisticated beam instrumentation is needed to measure particle coordinates and timing vs RF. A PID system based on three time-of-flight stations, two Aerogel Cerenkov detectors and a KLOE-like calorimeter has been constructed in order to keep beam contamination ($e, \\pi$) well below 1%. The MICE time-of-flight system will measure timing with a resolution better than 70 ps per plane, in a harsh environment due to high particle rates, fringe magnetic fields and electron backgrounds from RF dark current.

M. Bonesini

2008-10-02T23:59:59.000Z

65

Instrumented Pipeline Initiative  

SciTech Connect (OSTI)

This report summarizes technical progress achieved during the cooperative agreement between Concurrent Technologies Corporation (CTC) and U.S. Department of Energy to address the need for a for low-cost monitoring and inspection sensor system as identified in the Department of Energy (DOE) National Gas Infrastructure Research & Development (R&D) Delivery Reliability Program Roadmap.. The Instrumented Pipeline Initiative (IPI) achieved the objective by researching technologies for the monitoring of pipeline delivery integrity, through a ubiquitous network of sensors and controllers to detect and diagnose incipient defects, leaks, and failures. This report is organized by tasks as detailed in the Statement of Project Objectives (SOPO). The sections all state the objective and approach before detailing results of work.

Thomas Piro; Michael Ream

2010-07-31T23:59:59.000Z

66

The MICE PID Instrumentation  

E-Print Network [OSTI]

The international Muon Ionization Cooling Experiment (MICE) will carry out a systematic investigation of ionization cooling of a muon beam. As the emittance measurement will be done on a particle-by-particle basis, sophisticated beam instrumentation is needed to measure particle coordinates and timing vs RF. A PID system based on three time-of-flight stations, two Aerogel Cerenkov detectors and a KLOE-like calorimeter has been constructed in order to keep beam contamination ($e, \\pi$) well below 1%. The MICE time-of-flight system will measure timing with a resolution better than 70 ps per plane, in a harsh environment due to high particle rates, fringe magnetic fields and electron backgrounds from RF dark current.

Bonesini, M

2008-01-01T23:59:59.000Z

67

E-Print Network 3.0 - akari far-infrared instrument Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

also have a capability for imaging... instruments, the Far-Infrared Surveyor (FIS; Kawada et al. 2007) and the Infrared Camera (IRC; Onaka et al... . AKARI has a 68.5 cm...

68

Research Report Hedonic and Instrumental  

E-Print Network [OSTI]

Mitchell,1 and James J. Gross2 1 Boston College and 2 Stanford University ABSTRACT--What motivates, & Rodriguez, 1989). Such instrumental motives might play a role in the regulation of emotion (Parrott, 1993

Gross, James J.

69

Departmental Business Instrument Numbering System  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

To prescribe procedures for assigning identifying numbers to all Department of Energy (DOE), including the National Nuclear Security Administration, business instruments. Cancels DOE 1331.2B. Canceled by DOE O 540.1A.

2000-12-05T23:59:59.000Z

70

Departmental Business Instrument Numbering System  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The Order prescribes the procedures for assigning identifying numbers to all Department of Energy (DOE) and National Nuclear Security Administration (NNSA) business instruments. Cancels DOE O 540.1. Canceled by DOE O 540.1B.

2005-01-27T23:59:59.000Z

71

Readiness Issues for Emergency Response Instrumentation  

SciTech Connect (OSTI)

Issues in maintaining readiness of instruments for deployment and use in emergency response situation often differ from those in maintaining instruments for normal operations. Confunding circumstances include use of non-availability of check sources, ensuring instruments are always in calibration and operable, possible use of instruments in different climates, packaging of instrumentation for deployment, transport of instrumentation and check sources, and ensuring users are familiar with instruments. Methods and procedures for addressing these issues are presented. Instrumentation used for survey, in situ measurements, electronic dosimetry, and air conditioning are discussed.

C.A. Riland; D.R. Bowman; R.J. Tighe

1999-03-01T23:59:59.000Z

72

International Conference Synchrotron Radiation Instrumentation SRI `94  

SciTech Connect (OSTI)

This report contains abstracts for the international conference on Synchrotron Radiation Instrumentation at Brookhaven National Laboratory.

Not Available

1994-10-01T23:59:59.000Z

73

ACRF Instrumentation Status and Information - June 2009  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

JW Voyles

2009-06-01T23:59:59.000Z

74

ACRF Instrumentation Status and Information September 2009  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

JW Voyles

2009-10-01T23:59:59.000Z

75

ACRF Instrumentation Status and Information July 2009  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

JW Voyles

2009-08-13T23:59:59.000Z

76

ACRF Instrumentation Status and Information April 2009  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

JW Voyles

2009-05-07T23:59:59.000Z

77

ACRF Instrumentation Status and Information August 2009  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

JW Voyles

2009-09-09T23:59:59.000Z

78

ACRF Instrumentation Status and Information May 2009  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

JW Voyles

2009-05-01T23:59:59.000Z

79

Instrumentation  

E-Print Network [OSTI]

indicate the following results. (i) Fair agreement is obtained with the theory of Stine and Wanlass 2 at

J. Picken; B. Sc; R. Harmer; J. Picken; B. Sc; R. Harmer; A Nol

1958-01-01T23:59:59.000Z

80

Lecture 2. Instrumentation Is the Sun very bright so we can never be photon hungry?  

E-Print Network [OSTI]

a secondary flat, so images are not rotated. Coelostats #12;12 Turret Altazimuth mirror arrangement Kitt Peak;9 Consideration of telescope focal length Diameter of solar image in the focal plane: f : focal length A : Sun to generate effective focal length. Arfd /2 B) Long Primary Focus Instrument #12;10 Heliostat primary mirror

Note: This page contains sample records for the topic "imaging instrumentation radiobiology" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Applications of digital image processing IX: SPIE volume 697  

SciTech Connect (OSTI)

This book contains papers arranged into six sessions. The session titles are: Image compression; Instrumentation; Theoretical concepts; Algorithms; Registration and modeling; and Restoration and enhancement.

Teacher, A.G.

1986-01-01T23:59:59.000Z

82

Dosimetric and Radiobiological Consequences of Computed Tomography–Guided Adaptive Strategies for Intensity Modulated Radiation Therapy of the Prostate  

SciTech Connect (OSTI)

Purpose: To examine a range of scenarios for image-guided adaptive radiation therapy of prostate cancer, including different schedules for megavoltage CT imaging, patient repositioning, and dose replanning. Methods and Materials: We simulated multifraction dose distributions with deformable registration using 35 sets of megavoltage CT scans of 13 patients. We computed cumulative dose–volume histograms, from which tumor control probabilities and normal tissue complication probabilities (NTCPs) for rectum were calculated. Five-field intensity modulated radiation therapy (IMRT) with 18-MV x-rays was planned to achieve an isocentric dose of 76 Gy to the clinical target volume (CTV). The differences between D{sub 95}, tumor control probability, V{sub 70Gy}, and NTCP for rectum, for accumulated versus planned dose distributions, were compared for different target volume sizes, margins, and adaptive strategies. Results: The CTV D{sub 95} for IMRT treatment plans, averaged over 13 patients, was 75.2 Gy. Using the largest CTV margins (10/7 mm), the D{sub 95} values accumulated over 35 fractions were within 2% of the planned value, regardless of the adaptive strategy used. For tighter margins (5 mm), the average D{sub 95} values dropped to approximately 73.0 Gy even with frequent repositioning, and daily replanning was necessary to correct this deficit. When personalized margins were applied to an adaptive CTV derived from the first 6 treatment fractions using the STAPLE (Simultaneous Truth and Performance Level Estimation) algorithm, target coverage could be maintained using a single replan 1 week into therapy. For all approaches, normal tissue parameters (rectum V{sub 70Gy} and NTCP) remained within acceptable limits. Conclusions: The frequency of adaptive interventions depends on the size of the CTV combined with target margins used during IMRT optimization. The application of adaptive target margins (<5 mm) to an adaptive CTV determined 1 week into therapy minimizes the need for subsequent dose replanning.

Battista, Jerry J., E-mail: j2b@uwo.ca [Department of Medical Biophysics, Western University, London, ON (Canada); Department of Oncology, Western University, London, ON (Canada); London Regional Cancer Program, London Health Sciences Centre, London, ON (Canada); Johnson, Carol; Turnbull, David; Kempe, Jeff [London Regional Cancer Program, London Health Sciences Centre, London, ON (Canada); Bzdusek, Karl [Philips Healthcare (Radiation Oncology Systems), Fitchburg, Wisconsin (United States); Van Dyk, Jacob; Bauman, Glenn [Department of Medical Biophysics, Western University, London, ON (Canada); Department of Oncology, Western University, London, ON (Canada); London Regional Cancer Program, London Health Sciences Centre, London, ON (Canada)

2013-12-01T23:59:59.000Z

83

Nuclear Instruments and Methods in Physics Research A 542 (2005) 134141 Study of water distribution and transport in a polymer  

E-Print Network [OSTI]

Nuclear Instruments and Methods in Physics Research A 542 (2005) 134­141 Study of water has been developed at the Penn State Breazeale Nuclear Reactor. Neutron images allow us to visualize

Mench, Matthew M.

84

Using a 3D Needle Tissue Interaction Loading basis to optimize the design of an instrumented needle  

E-Print Network [OSTI]

Using a 3D Needle ­Tissue Interaction Loading basis to optimize the design of an instrumented-IMAG UMR5525, Grenoble, France Keywords: Needle deformation; Load distribution; Instrumented needle of the needle which does not follow the planned trajectory. Furthermore, the amount of irradiation during

Paris-Sud XI, Université de

85

Principal Components Instrumental Variable Estimation  

E-Print Network [OSTI]

of the main results are displayed in two appendices. 2 Econometric Framework Consider the simultaneous equations model y = X? + u and X = Z?+ V , (1) 1 An advantage of such general structure is that the ‘large-sample’ condition used in previous studies Kn/ p n... ? 0, where Kn is the number of instruments and n is the sample size, is not required in our asymptotic approximations. 4 where y is the n × 1 vector containing n observations of the dependent variable; X is the n × G matrix with observations...

Winkelried, Diego; Smith, Richard J.

2011-01-31T23:59:59.000Z

86

Tevatron instrumentation: boosting collider performance  

SciTech Connect (OSTI)

The Tevatron in Collider Run II (2001-present) is operating with six times more bunches, many times higher beam intensities and luminosities than in Run I (1992-1995). Beam diagnostics were crucial for the machine start-up and the never-ending luminosity upgrade campaign. We present the overall picture of the Tevatron diagnostics development for Run II, outline machine needs for new instrumentation, present several notable examples that led to Tevatron performance improvements, and discuss the lessons for the next big machines--LHC and ILC.

Shiltsev, Vladimir; Jansson, Andreas; Moore, Ronald; /Fermilab

2006-05-01T23:59:59.000Z

87

SECTION V: SUPERCONDUCTING CYCLOTRON, INSTRUMENTATION  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the1 -the Mid-Infrared0 ResourceAwards SAGE Awards ,# , onLightThe natureINSTRUMENTATION

88

ARM - AMF1 Baseline Instruments  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary)morphinanInformation Desert SouthwestTechnologies |November 2011AstudiesRingFacilitiesAMF1 Baseline Instruments AMF

89

The GRAVITY instrument software / High-level software  

E-Print Network [OSTI]

GRAVITY is the four-beam, near- infrared, AO-assisted, fringe tracking, astrometric and imaging instrument for the Very Large Telescope Interferometer (VLTI). It is requiring the development of one of the most complex instrument software systems ever built for an ESO instrument. Apart from its many interfaces and interdependencies, one of the most challenging aspects is the overall performance and stability of this complex system. The three infrared detectors and the fast reflective memory network (RMN) recorder contribute a total data rate of up to 20 MiB/s accumulating to a maximum of 250 GiB of data per night. The detectors, the two instrument Local Control Units (LCUs) as well as the five LCUs running applications under TAC (Tools for Advanced Control) architecture, are interconnected with fast Ethernet, RMN fibers and dedicated fiber connections as well as signals for the time synchronization. Here we give a simplified overview of all subsystems of GRAVITY and their interfaces and discuss two examples of...

Burtscher, Leonard; Ott, Thomas; Kok, Yitping; Yazici, Senol; Anugu, Narsireddy; Dembet, Roderick; Fedou, Pierre; Lacour, Sylvestre; Ott, Juergen; Paumard, Thibaut; Lapeyrere, Vincent; Kervella, Pierre; Abuter, Roberto; Pozna, Eszter; Eisenhauer, Frank; Blind, Nicolas; Genzel, Reinhard; Gillessen, Stefan; Hans, Oliver; Haug, Marcus; Haussmann, Frank; Kellner, Stefan; Lippa, Magdalena; Pfuhl, Oliver; Sturm, Eckhard; Weber, Johannes; Amorim, Antonio; Brandner, Wolfgang; Rousselet-Perraut, Karine; Perrin, Guy S; Straubmeier, Christian; Schoeller, Markus

2015-01-01T23:59:59.000Z

90

Medical imaging with coded apertures  

SciTech Connect (OSTI)

Now algorithms were investigated for image reconstruction in emission tomography which could incorporate complex instrumental effects such as might be obtained with a coded aperture system. The investigation focused on possible uses of the wavelet transform to handle non-stationary instrumental effects and analytic continuation of the Radon transform to handle self-absorption. Neither investigation was completed during the funding period and whether such algorithms will be useful remains an open question.

Keto, E.; Libby, S.

1995-06-16T23:59:59.000Z

91

Calibration facility for environment dosimetry instruments  

SciTech Connect (OSTI)

In the last ten years, the nuclear activities, as well as the major nuclear events (see Fukushima accident) had an increasing impact on the environment, merely by contamination with radioactive materials. The most conferment way to quickly identify the presence of some radioactive elements in the environment, is to measure the dose-equivalent rate H. In this situation, information concerning the values of H due only to the natural radiation background must exist. Usually, the values of H due to the natural radiation background, are very low (?10{sup ?9} - 10{sup ?8} Sv/h). A correct measurement of H in this range involve a performing calibration of the measuring instruments in the measuring range corresponding to the natural radiation background lead to important problems due to the presence of the natural background itself the best way to overlap this difficulty is to set up the calibration stand in an area with very low natural radiation background. In Romania, we identified an area with such special conditions at 200 m dept, in a salt mine. This paper deals with the necessary requirements for such a calibration facility, as well as with the calibration stand itself. The paper includes also, a description of the calibration stand (and images) as well as the radiological and metrological parameters. This calibration facilities for environment dosimetry is one of the few laboratories in this field in Europe.

Bercea, Sorin; Celarel, Aurelia; Cenusa, Constantin [Horia Hulubei National Institute for Physics and Nuclear Engineering, 30 Reactorului St, Magurele, Jud Ilfov, P.O.B. MG-6, RO-077125 (Romania)

2013-12-16T23:59:59.000Z

92

Overview of coal conversion process instrumentation  

SciTech Connect (OSTI)

A review of standard instrumentation used in the processing industries is given, and the applicability of this instrumentation to measurements in mixed phase media and hostile environments such as those encountered in coal conversion processes is considered. The major projects in coal conversion sponsored by the US Department of Energy are briefly reviewed with schematics to pinpoint areas where the standard instrumentation is inadequate or altogether lacking. The next report in this series will provide detailed requirements on the instruments needed for these processes, will review new instruments which have recently become commercially available but are not yet considered standard instrumentation, and report on the status of new instruments which are being developed and, in some cases, undergoing tests in coal conversion plants.

Liptak, B. G.; Leiter, C. P.

1980-05-01T23:59:59.000Z

93

Bioelectrical strategies for image-guided therapies  

E-Print Network [OSTI]

There is a pressing need in minimally-invasive surgery for novel imaging methods that can rapidly and accurately localize the surgical instrument and its target. We have developed two novel localization methods for the ...

Barley, Maya

2007-01-01T23:59:59.000Z

94

MC and A instrumentation catalog  

SciTech Connect (OSTI)

In 1981 and 1985, two editions of a catalog of non-destructive nuclear measurement instrumentation, and material control and surveillance equipment, were published by Brookhaven National Laboratory (BNL). The last edition of the catalog included one hundred and twenty-five entries covering a wide range of devices developed in the US and abroad. More than ten years have elapsed since the publication of the more recent Catalog. Devices described in it have undergone significant modifications, and new devices have been developed. Therefore, in order to assist specialists in the field of Material Control and Accounting (MC and A), a new catalog has been created. Work on this instrumentation catalog started in 1997 as a cooperative effort of Brookhaven National Laboratory (BNL), operated by Brookhaven Science Associates under contract to the US Department of Energy, and the All-Russian Research Institute of Automatics (VNIIA), subordinate institute of the Atomic Energy Ministry of the Russian Federation, within the collaborative US-Russia Material Protection, Control, and Accounting (MPC and A) Program. Most of the equipment included in the Catalog are non-destructive assay (NDA) measurement devices employed for purposes of accounting, confirmation, and verification of nuclear materials. Other devices also included in the Catalog are employed in the detection and deterrence of unauthorized access to or removal of nuclear materials (material control: containment and surveillance). Equipment found in the Catalog comprises either: (1) complete devices or systems that can be used for MC and A applications; or (2) parts or components of complete systems, such as multi-channel analyzers, detectors, neutron generators, and software. All devices are categorized by their status of development--from prototype to serial production.

Neymotin, L. [ed.] [Brookhaven National Lab., Upton, NY (United States); Sviridova, V. [ed.] [All-Russian Research Inst. of Automatics, Moscow (Russian Federation)

1998-06-01T23:59:59.000Z

95

Quantitative luminescence imaging system  

DOE Patents [OSTI]

The QLIS images and quantifies low-level chemiluminescent reactions in an electromagnetic field. It is capable of real time nonperturbing measurement and simultaneous recording of many biochemical and chemical reactions such as luminescent immunoassays or enzyme assays. The system comprises image transfer optics, a low-light level digitizing camera with image intensifying microchannel plates, an image process or, and a control computer. The image transfer optics may be a fiber image guide with a bend, or a microscope, to take the light outside of the RF field. Output of the camera is transformed into a localized rate of cumulative digitalized data or enhanced video display or hard-copy images. The system may be used as a luminescent microdosimetry device for radiofrequency or microwave radiation, as a thermal dosimeter, or in the dosimetry of ultra-sound (sonoluminescence) or ionizing radiation. It provides a near-real-time system capable of measuring the extremely low light levels from luminescent reactions in electromagnetic fields in the areas of chemiluminescence assays and thermal microdosimetry, and is capable of near-real-time imaging of the sample to allow spatial distribution analysis of the reaction. It can be used to instrument three distinctly different irradiation configurations, comprising (1) RF waveguide irradiation of a small Petri-dish-shaped sample cell, (2) RF irradiation of samples in a microscope for the microscopie imaging and measurement, and (3) RF irradiation of small to human body-sized samples in an anechoic chamber.

Erwin, David N. (San Antonio, TX); Kiel, Johnathan L. (San Antonio, TX); Batishko, Charles R. (West Richland, WA); Stahl, Kurt A. (Richland, WA)

1990-01-01T23:59:59.000Z

96

Quantitative luminescence imaging system  

DOE Patents [OSTI]

The QLIS images and quantifies low-level chemiluminescent reactions in an electromagnetic field. It is capable of real time nonperturbing measurement and simultaneous recording of many biochemical and chemical reactions such as luminescent immunoassays or enzyme assays. The system comprises image transfer optics, a low-light level digitizing camera with image intensifying microchannel plates, an image process or, and a control computer. The image transfer optics may be a fiber image guide with a bend, or a microscope, to take the light outside of the RF field. Output of the camera is transformed into a localized rate of cumulative digitalized data or enhanced video display or hard-copy images. The system may be used as a luminescent microdosimetry device for radiofrequency or microwave radiation, as a thermal dosimeter, or in the dosimetry of ultra-sound (sonoluminescence) or ionizing radiation. It provides a near-real-time system capable of measuring the extremely low light levels from luminescent reactions in electromagnetic fields in the areas of chemiluminescence assays and thermal microdosimetry, and is capable of near-real-time imaging of the sample to allow spatial distribution analysis of the reaction. It can be used to instrument three distinctly different irradiation configurations, comprising (1) RF waveguide irradiation of a small Petri-dish-shaped sample cell, (2) RF irradiation of samples in a microscope for the microscopic imaging and measurement, and (3) RF irradiation of small to human body-sized samples in an anechoic chamber. 22 figs.

Erwin, D.N.; Kiel, J.L.; Batishko, C.R.; Stahl, K.A.

1990-08-14T23:59:59.000Z

97

RADIOBIOLOGICAL LABORATORY BEAUFORT, N. C.  

E-Print Network [OSTI]

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Accumulation of zinc 65 from food and water by juvenile flounde r Acute and fractionated irradiation of early embryos of mummichog · . · . · . · . . . . · · . . . . . . . · . . 28 Continuous low-level irradiation of post-lar val flounders

98

aexs instrument development: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

interferometer Ohta, Shigemi 2 Development of Models for Optical Instrument Transformers. Open Access Theses and Dissertations Summary: ??Optical Instrument Transformers...

99

Computational and experimental study of instrumented indentation  

E-Print Network [OSTI]

The effect of characteristic length scales, through dimensional and microstructural miniaturizations, on mechanical properties is systematically investigated by recourse to instrumented micro- and/or nanoindentation. This ...

Chollacoop, Nuwong, 1977-

2004-01-01T23:59:59.000Z

100

Rotary mode system initial instrument calibration  

SciTech Connect (OSTI)

The attached report contains the vendor calibration procedures used for the initial instrument calibration of the rotary core sampling equipment. The procedures are from approved vendor information files.

Johns, B.R.

1994-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "imaging instrumentation radiobiology" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Kids with disabilities inspire a musical instrument  

ScienceCinema (OSTI)

The Midiwing is a musical instrument that unites music and computer technology for those who lack the experience, physical ability, or maturity to play music with traditional instruments. To create the instrument, Dan Daily, Director of Musicode Innovations, reworked and recoded Musical Instrument Digital Interface (MIDI) technology and introduced ergonomic design. He applied to the New Mexico Small Business Assistance (NMSBA) Program to receive help when he discovered the microcontroller he used was being phased out. Daily and Kent Pfeifer, an engineer at Sandia National Laboratories and musician himself, partnered to create a new state-of-the-art design.

Daily, Dan; Pfeifer, Kent

2014-02-10T23:59:59.000Z

102

Instrumentation, Control, and Intelligent Systems  

SciTech Connect (OSTI)

Abundant and affordable energy is required for U.S. economic stability and national security. Advanced nuclear power plants offer the best near-term potential to generate abundant, affordable, and sustainable electricity and hydrogen without appreciable generation of greenhouse gases. To that end, Idaho National Laboratory (INL) has been charged with leading the revitalization of nuclear power in the U.S. The INL vision is to become the preeminent nuclear energy laboratory with synergistic, world-class, multi-program capabilities and partnerships by 2015. The vision focuses on four essential destinations: (1) Be the preeminent internationally-recognized nuclear energy research, development, and demonstration laboratory; (2) Be a major center for national security technology development and demonstration; (3) Be a multi-program national laboratory with world-class capabilities; (4) Foster academic, industry, government, and international collaborations to produce the needed investment, programs, and expertise. Crucial to that effort is the inclusion of research in advanced instrumentation, control, and intelligent systems (ICIS) for use in current and advanced power and energy security systems to enable increased performance, reliability, security, and safety. For nuclear energy plants, ICIS will extend the lifetime of power plant systems, increase performance and power output, and ensure reliable operation within the system's safety margin; for national security applications, ICIS will enable increased protection of our nation's critical infrastructure. In general, ICIS will cost-effectively increase performance for all energy security systems.

Not Available

2005-09-01T23:59:59.000Z

103

SLAC All Access: Atomic, Molecular and Optical Science Instrument  

ScienceCinema (OSTI)

John Bozek, a staff scientist at SLAC's Linac Coherent Light Source (LCLS) X-ray laser who manages the LCLS Soft X-ray Department, takes us behind the scenes at the Atomic, Molecular and Optical Science (AMO) instrument, the first of six experimental stations now operating at LCLS. Samples used in AMO experiments include atoms, molecules, clusters, and nanoscale objects such as protein crystals or viruses. Science performed at AMO includes fundamental studies of light-matter interactions in the extreme X-ray intensity of the LCLS pules, time-resolved studies of increasingly charged states of atoms and molecules, X-ray diffraction imaging of nanocrystals, and single-shot imaging of a variety of objects.

Bozek, John

2014-06-03T23:59:59.000Z

104

Effect of geotropism on instrument readings  

SciTech Connect (OSTI)

A review of gravity's effect on instrument readings, also referred to as geotropism. In this essay a review of meter movement construction and the effect are reviewed as it applies to portable radiation instruments. Reference to the three ANSI standards and their requirements are reviewed. An alternate approach to test for the effects is offered.

Rolph, James T.

2006-11-01T23:59:59.000Z

105

Microfabricated field calibration assembly for analytical instruments  

DOE Patents [OSTI]

A microfabricated field calibration assembly for use in calibrating analytical instruments and sensor systems. The assembly comprises a circuit board comprising one or more resistively heatable microbridge elements, an interface device that enables addressable heating of the microbridge elements, and, in some embodiments, a means for positioning the circuit board within an inlet structure of an analytical instrument or sensor system.

Robinson, Alex L. (Albuquerque, NM); Manginell, Ronald P. (Albuquerque, NM); Moorman, Matthew W. (Albuquerque, NM); Rodacy, Philip J. (Albuquerque, NM); Simonson, Robert J. (Cedar Crest, NM)

2011-03-29T23:59:59.000Z

106

Void Fraction Instrument operation and maintenance manual  

SciTech Connect (OSTI)

This Operations and Maintenance Manual (O&MM) addresses riser installation, equipment and personnel hazards, operating instructions, calibration, maintenance, removal, and other pertinent information necessary to safely operate and store the Void Fraction Instrument. Final decontamination and decommissioning of the Void Fraction Instrument are not covered in this document.

Borgonovi, G.; Stokes, T.I.; Pearce, K.L.; Martin, J.D.; Gimera, M.; Graves, D.B.

1994-09-01T23:59:59.000Z

107

LCLS-II New Instruments Workshops Report  

SciTech Connect (OSTI)

The LCLS-II New Instruments workshops chaired by Phil Heimann and Jerry Hastings were held on March 19-22, 2012 at the SLAC National Accelerator Laboratory. The goal of the workshops was to identify the most exciting science and corresponding parameters which will help define the LCLS-II instrumentation. This report gives a synopsis of the proposed investigations and an account of the workshop. Scientists from around the world have provided short descriptions of the scientific opportunities they envision at LCLS-II. The workshops focused on four broadly defined science areas: biology, materials sciences, chemistry and atomic, molecular and optical physics (AMO). Below we summarize the identified science opportunities in the four areas. The frontiers of structural biology lie in solving the structures of large macromolecular biological systems. Most large protein assemblies are inherently difficult to crystallize due to their numerous degrees of freedom. Serial femtosecond protein nanocrystallography, using the 'diffraction-before-destruction' approach to outrun radiation damage has been very successfully pioneered at LCLS and diffraction patterns were obtained from some of the smallest protein crystals ever. The combination of femtosecond x-ray pulses of high intensity and nanosized protein crystals avoids the radiation damage encountered by conventional x-ray crystallography with focused beams and opens the door for atomic structure determinations of the previously largely inaccessible class of membrane proteins that are notoriously difficult to crystallize. The obtained structures will allow the identification of key protein functions and help in understanding the origin and control of diseases. Three dimensional coherent x-ray imaging at somewhat lower resolution may be used for larger objects such as viruses. The chemistry research areas of primary focus are the predictive understanding of catalytic mechanisms, with particular emphasis on photo- and heterogeneous catalysis. Of particular interest is the efficient conversion of light to electrical or chemical energy, which requires understanding the non-adiabatic dynamics of electronic excited states. Ultrafast x-ray scattering presents an excellent opportunity to investigate structural dynamics of molecular systems with atomic resolution, and x-ray scattering and spectroscopy present an excellent opportunity to investigating the dynamics of the electronic charge distribution. Harnessing solar energy to generate fuels, either indirectly with photovoltaics and electrochemical catalysis or directly with photocatalysts, presents a critical technological challenge that will require the use of forefront scientific tools such as ultrafast x-rays. At the center of this technical challenge is the rational design of efficient and cost effective catalysts. Important materials science opportunities relate to information technology applications, in particular the transport and storage of information on increasingly smaller length- and faster time-scales. Of interest are the understanding of the intrinsic size limits associated with the storage of information bits and the speed limits of information or bit processing. Key questions revolve about how electronic charges and spins of materials can be manipulated by electric and magnetic fields. This requires the exploration of speed limits subject to the fundamental conservation laws of energy and linear and angular momentum and the different coupling of polar electric and axial magnetic fields to charge and spin. Of interest are novel composite materials, including molecular systems combining multi electric and magnetic functionality. Ultrafast x-rays offer the required probing speed, can probe either the charge or spin properties through polarization control and through scattering and spectroscopy cover the entire energy-time-momentum-distance phase space. In the field of atomic and molecular science, LCLS II promises to elucidate the fundamental interactions among electrons and between electrons and nuclei, and to explore the fron

Baradaran, Samira; Bergmann, Uwe; Durr, Herrmann; Gaffney, Kelley; Goldstein, Julia; Guehr, Markus; Hastings, Jerome; Heimann, Philip; Lee, Richard; Seibert, Marvin; Stohr, Joachim; /SLAC; ,

2012-08-08T23:59:59.000Z

108

Applications of transputers to astronomical instruments  

SciTech Connect (OSTI)

Parallel processing techniques based on transputers are being applied to astronomical instruments under development. On the COSMOS photographic plate measuring machine, a data farm of transputers allows backgrounds to be determined in realtime instead of requiring 1.5 hours of offline VAX processing per plate. Transputers have been adopted as the embedded processors in a submillimetre bolometer array instrument and their use is planned in demanding future applications such as thermal infrared array instruments and data compression applied to remote observing. The techniques of interfacing transputers to external hardware and to VAX/VMS computers are discussed.

Stewart, J.M.; Beard, S,M.; Kelly, B.D.; Paterson, M.J. (Royal Observatory, Edinburgh (UK))

1990-04-01T23:59:59.000Z

109

Plasma instrumentation for fusion power reactor control  

SciTech Connect (OSTI)

Feedback control will be implemented in fusion power reactors to guard against unpredicted behavior of the plant and to assure desirable operation. In this study, plasma state feedback requirements for plasma control by systems strongly coupled to the plasma (magnet sets, RF, and neutral beam heating systems, and refueling systems) are estimated. Generic considerations regarding the impact of the power reactor environment on plasma instrumentation are outlined. Solutions are proposed to minimize the impact of the power reactor environment on plasma instrumentation. Key plasma diagnostics are evaluated with respect to their potential for upgrade and implementation as power reactor instruments.

Sager, G.T.; Bauer, J.F.; Maya, I.; Miley, G.H.

1985-07-01T23:59:59.000Z

110

ACRF Instrumentation Status: New, Current, and Future March 2007  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Program Climate Research Facility instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

JC Liljegren

2007-03-01T23:59:59.000Z

111

ACRF Instrumentation Status: New, Current, and Future June 2007  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Program Climate Research Facility instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

JC Liljegren

2007-06-01T23:59:59.000Z

112

ACRF Instrumentation Status: New, Current, and Future May 2007  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Program Climate Research Facility instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

JC Liljegren

2007-05-01T23:59:59.000Z

113

ACRF Instrumentation Status: New, Current, and Future February 2007  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Program Climate Research Facility instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development

JC Liljegren

2007-02-01T23:59:59.000Z

114

ACRF Instrumentation Status: New, Current, and Future January 2007  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Program Climate Research Facility instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

JC Liljegren

2007-01-01T23:59:59.000Z

115

ACRF Instrumentation Status: New, Current, and Future - March 2008  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

JW Voyles

2008-04-01T23:59:59.000Z

116

ACRF Instrumentation Status: New, Current, and Future - November – December 2007  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

JW Voyles

2007-12-01T23:59:59.000Z

117

ACRF Instrumentation Status: New, Current, and Future - September – October 2007  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement (ARM) Climate Research Facility (ACRF) instrumentation status. The report is divided into the following four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) SBIR instrument development.

JW Voyles

2007-10-30T23:59:59.000Z

118

ACRF Instrumentation Status: New, Current, and Future July 2007  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of ACRF instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) SBIR instrument development.

JC Liljegren

2007-07-01T23:59:59.000Z

119

ACRF Instrumentation Status: New, Current, and Future - February 2008  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

JW Voyles

2008-03-01T23:59:59.000Z

120

ACRF Instrumentation Status: New, Current, and Future May 2007  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Program Climate Research Facility instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

JC Liljegren

2007-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "imaging instrumentation radiobiology" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

ACRF Instrumentation Status: New, Current, and Future October 2006  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Program Climate Research Facility instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

JC Liljegren

2006-10-01T23:59:59.000Z

122

Original article Natural mating of instrumentally  

E-Print Network [OSTI]

before they start egg laying. Thus, the control over mating of parents is lost. To prevent this, queen INTRODUCTION Instrumental insemination assures control over mating of parents in the honey bee. However, Woyke

Paris-Sud XI, Université de

123

274 CEREAL CHEMISTRY ANALYTICAL TECHNIQUES AND INSTRUMENTATION  

E-Print Network [OSTI]

274 CEREAL CHEMISTRY ANALYTICAL TECHNIQUES AND INSTRUMENTATION Evaluation of the Displacement Value). Production of fuel-grade ethanol, initiated in the late 1970's as a result of rising gasoline prices

124

A nano-stepping robotic instrumentation platform  

E-Print Network [OSTI]

The development of an Autonomous Nano-stepping Tool (ANT) system is presented. Each ANT is a small, tripodal, robotic instrument capable of untethered precision motion within a quasi-three-dimensional workspace of arbitrary ...

Wahab, Adam Joseph

2013-01-01T23:59:59.000Z

125

Optimization of naïve dynamic binary instrumentation Tools/  

E-Print Network [OSTI]

The proliferation of dynamic program analysis tools has done much to ease the burden of developing complex software. However, creating such tools remains a challenge. Dynamic binary instrumentation frameworks such as ...

Kleckner, Reid (Reid N.)

2011-01-01T23:59:59.000Z

126

Cellular telephone-based radiation detection instrument  

DOE Patents [OSTI]

A network of radiation detection instruments, each having a small solid state radiation sensor module integrated into a cellular phone for providing radiation detection data and analysis directly to a user. The sensor module includes a solid-state crystal bonded to an ASIC readout providing a low cost, low power, light weight compact instrument to detect and measure radiation energies in the local ambient radiation field. In particular, the photon energy, time of event, and location of the detection instrument at the time of detection is recorded for real time transmission to a central data collection/analysis system. The collected data from the entire network of radiation detection instruments are combined by intelligent correlation/analysis algorithms which map the background radiation and detect, identify and track radiation anomalies in the region.

Craig, William W. (Pittsburg, CA); Labov, Simon E. (Berkeley, CA)

2011-06-14T23:59:59.000Z

127

Field instrumentation for vocalizing avian survey  

E-Print Network [OSTI]

We present automated instruments to facilitate the monitoring of vocalizing species in their environment with minimal disruption. These devices offer recording and acoustic localization of bird calls and relay data via the ...

Elliott, Grant (Grant Andrew)

2007-01-01T23:59:59.000Z

128

X-Ray Nanoimaging: Instruments and Methods  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

X-Ray Nanoimaging: Instruments and Methods To be held as part of SPIE. http:spie.orgOP318 August 28-29, 2013; San Diego, California, USA...

129

Extending the frontiers of mass spectrometric instrumentation and methods  

SciTech Connect (OSTI)

The focus of this dissertation is two-fold: developing novel analysis methods using mass spectrometry and the implementation and characterization of a novel ion mobility mass spectrometry instrumentation. The novel mass spectrometry combines ion trap for ion/ion reactions coupled to an ion mobility cell. The long term goal of this instrumentation is to use ion/ion reactions to probe the structure of gas phase biomolecule ions. The three ion source - ion trap - ion mobility - qTOF mass spectrometer (IT - IM - TOF MS) instrument is described. The analysis of the degradation products in coal (Chapter 2) and the imaging plant metabolites (Appendix III) fall under the methods development category. These projects use existing commercial instrumentation (JEOL AccuTOF MS and Thermo Finnigan LCQ IT, respectively) for the mass analysis of the degraded coal products and the plant metabolites, respectively. The coal degradation paper discusses the use of the DART ion source for fast and easy sample analysis. The sample preparation consisted of a simple 50 fold dilution of the soluble coal products in water and placing the liquid in front of the heated gas stream. This is the first time the DART ion source has been used for analysis of coal. Steven Raders under the guidance of John Verkade came up with the coal degradation projects. Raders performed the coal degradation reactions, worked up the products, and sent them to me. Gregg Schieffer developed the method and wrote the paper demonstrating the use of the DART ion source for the fast and easy sample analysis. The plant metabolite imaging project extends the use of colloidal graphite as a sample coating for atmospheric pressure LDI. DC Perdian and I closely worked together to make this project work. Perdian focused on building the LDI setup whereas Schieffer focused on the MSn analysis of the metabolites. Both Perdian and I took the data featured in the paper. Perdian was the primary writer of the paper and used it as a chapter in his dissertation. Perdian and Schieffer worked together to address the revisions and publish it in Rapid Communications in Mass Spectrometry Journal.

Schieffer, Gregg

2010-12-15T23:59:59.000Z

130

National Instruments online training and training credits offering...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

National Instruments online training and training credits offering The lab has entered into an Enterprise Agreement with National Instruments (NI) to offer online training and...

131

IceCube: An Instrument for Neutrino Astronomy  

E-Print Network [OSTI]

An Instrument for Neutrino Astronomy Francis Halzen 1 andAn Instrument for Neutrino Astronomy Francis Halzen 1 and94720 Abstract Neutrino astronomy beyond the Sun was first

Halzen, F.

2010-01-01T23:59:59.000Z

132

Surveillance Guides - QAS 2.4 Instrument Calibration  

Broader source: Energy.gov (indexed) [DOE]

of the contractor's program to routinely calibrate instruments, alarms, and sensors. The Facility Representative observes calibration testing of instruments and channels...

133

SciTech Connect: Nuclear power reactor instrumentation systems...  

Office of Scientific and Technical Information (OSTI)

Nuclear power reactor instrumentation systems handbook. Volume 1 Citation Details In-Document Search Title: Nuclear power reactor instrumentation systems handbook. Volume 1 You...

134

Test Images  

E-Print Network [OSTI]

Test Images. I hope to have a set of test images for the course soon. Some images are available now; some will have to wait until I can find another 100-200

135

Calibration of LSST Instrumental and Atmospheric Photometric Passbands  

SciTech Connect (OSTI)

The Large Synoptic Survey Telescope (LSST) will continuously image the entire sky visible from Cerro Pachon in northern Chile every 3-4 nights throughout the year. The LSST will provide data for a broad range of science investigations that require better than 1% photometric precision across the sky (repeatability and uniformity) and a similar accuracy of measured broadband color. The fast and persistent cadence of the LSST survey will significantly improve the temporal sampling rate with which celestial events and motions are tracked. To achieve these goals, and to optimally utilize the observing calendar, it will be necessary to obtain excellent photometric calibration of data taken over a wide range of observing conditions - even those not normally considered 'photometric'. To achieve this it will be necessary to routinely and accurately measure the full optical passband that includes the atmosphere as well as the instrumental telescope and camera system. The LSST mountain facility will include a new monochromatic dome illumination projector system to measure the detailed wavelength dependence of the instrumental passband for each channel in the system. The facility will also include an auxiliary spectroscopic telescope dedicated to measurement of atmospheric transparency at all locations in the sky during LSST observing. In this paper, we describe these systems and present laboratory and observational data that illustrate their performance.

Burke, David L.; /SLAC; Axelrod, T.; /Arizona U., Astron. Dept. - Steward Observ.; Barrau, Aurelien; Baumont, Sylvain; /LPSC, Grenoble; Blondin, Stephane; /Marseille, CPPM; Claver, Chuck; /NOAO, Tucson; Gorecki, Alexia; /LPSC, Grenoble; Ivezic, Zeljko; Jones, Lynne; /Washington U., Seattle, Astron. Dept.; Krabbendam, Victor; Liang, Ming; Saha, Abhijit; /NOAO, Tucson; Smith, Allyn; /Austin Peay State U.; Smith, R.Chris; /Cerro-Tololo InterAmerican Obs.; Stubbs, Christopher W.; /Harvard-Smithsonian Ctr. Astrophys.

2011-07-06T23:59:59.000Z

136

Image Analysis  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Recognition Image Analysis and Recognition Snapshot1498121slicesqResedison Fibers permeating imaged material (Courtesy: Bale, Loring, Perciano and Ushizima) Imagery coming from...

137

Instrumentation to Enhance Advanced Test Reactor Irradiations  

SciTech Connect (OSTI)

The Department of Energy (DOE) designated the Advanced Test Reactor (ATR) as a National Scientific User Facility (NSUF) in April 2007 to support U.S. leadership in nuclear science and technology. By attracting new research users - universities, laboratories, and industry - the ATR will support basic and applied nuclear research and development, further advancing the nation's energy security needs. A key component of the ATR NSUF effort is to prove new in-pile instrumentation techniques that are capable of providing real-time measurements of key parameters during irradiation. To address this need, an assessment of instrumentation available and under-development at other test reactors has been completed. Based on this review, recommendations are made with respect to what instrumentation is needed at the ATR and a strategy has been developed for obtaining these sensors. Progress toward implementing this strategy is reported in this document. It is anticipated that this report will be updated on an annual basis.

J. L. Rempe; D. L. Knudson; K. G. Condie; J. E. Daw; S. C. Taylor

2009-09-01T23:59:59.000Z

138

Advances in instrumentation for nuclear astrophysics  

SciTech Connect (OSTI)

The study of the nuclear physics properties which govern energy generation and nucleosynthesis in the astrophysical phenomena we observe in the universe is crucial to understanding how these objects behave and how the chemical history of the universe evolved to its present state. The low cross sections and short nuclear lifetimes involved in many of these reactions make their experimental determination challenging, requiring developments in beams and instrumentation. A selection of developments in nuclear astrophysics instrumentation is discussed, using as examples projects involving the nuclear astrophysics group at Oak Ridge National Laboratory. These developments will be key to the instrumentation necessary to fully exploit nuclear astrophysics opportunities at the Facility for Rare Isotope Beams which is currently under construction.

Pain, S. D. [Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States)] [Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States)

2014-04-15T23:59:59.000Z

139

Nuclear Instruments and Methods in Physics Research A 360 (1995) 189-192 INSTRUMENTS  

E-Print Network [OSTI]

ELSEVIER Nuclear Instruments and Methods in Physics Research A 360 (1995) 189-192 NUCLEARFaculty ofPhysics and Nuclear Techniques Academy ofMining and Metallurgy, Cracow, Poland h INFN, Torino INSTRUMENTS 8 METHODS IN PHYSICS RESEARCH SectIonA A fast, high-granularity silicon multiplicity detector

Ramello, Luciano

140

Nuclear Instruments and Methods in Physics Research A 356 (1995) l-4 INSTRUMENTS  

E-Print Network [OSTI]

ELSEVIER Nuclear Instruments and Methods in Physics Research A 356 (1995) l-4 NUCLEAR INSTRUMENTS 8 METHODS IN PHYSICS REgtR?n Thermodynamics of dynamic nuclear polarization W.Th. Wenckebach Faculty ofApplied Physics, Delfr Unicersity of Technology, P.O.B. 5046, 2600 GA De& The Netherlands Abstract Dynamic nuclear

Dutz, Hartmut

Note: This page contains sample records for the topic "imaging instrumentation radiobiology" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

UW SCHOOL OF PHARMACY INSTRUMENTATION COMMITTEE  

E-Print Network [OSTI]

UW SCHOOL OF PHARMACY INSTRUMENTATION COMMITTEE 2013-2014 Warren Heideman (chair) Mass spec users-related activities of the School. 4. Provide input and advice to the Dean on issues of importance to the AIC the research enterprise within the School of Pharmacy, across campus, and in the scientific community such as

Sheridan, Jennifer

142

Integrated polymerase chain reaction/electrophoresis instrument  

DOE Patents [OSTI]

A new approach and instrument for field identification of micro-organisms and DNA fragments using a small and disposable device containing integrated polymerase chain reaction (PCR) enzymatic reaction wells, attached capillary electrophoresis (CE) channels, detectors, and read-out all on/in a small hand-held package. The analysis instrument may be made inexpensively, for example, of plastic, and thus is disposable, which minimizes cross contamination and the potential for false positive identification between samples. In addition, it is designed for multiple users with individual applications. The integrated PCR/CE is manufactured by the PCR well and CE channels are "stamped" into plastic depressions where conductive coatings are made in the wells and ends of the CE microchannels to carry voltage and current to heat the PCR reaction mixtures and simultaneously draw DNA bands up the CE channels. Light is transmitted through the instrument at appropriate points and detects PCR bands and identifies DNA fragments by size (retention time) and quantifies each by the amount of light generated as each phototransistor positioned below each CE channel detects a passing band. The instrument is so compact that at least 100 PCR/CE reactions/analyses can be performed easily on one detection device.

Andresen, Brian D. (Livermore, CA)

2000-01-01T23:59:59.000Z

143

Regulative and voluntary instruments for responsible forest  

E-Print Network [OSTI]

carrotssermonssticks PES Comand and control Taxes and subsibies ­ Directness + Education ­Useofeconomicincentives,700 ha di farmland producing corn converted to organic · 92% of the area involved in the program · 200) A similar type of classification " Regulative instruments promoted by public institutions: international

Pettenella, Davide

144

Utility Indifference Pricing of Credit Instruments  

E-Print Network [OSTI]

in conformity with the requirements for the degree of Doctor of Philosophy Graduate Department of Mathematics Instruments Georg Sigloch Doctor of Philosophy Graduate Department of Mathematics University of Toronto 2009 consequences of being exposed to credit risk. In this thesis we address these issues by pricing credit

Jaimungal, Sebastian

145

STAR Images: Image gallery from the Solenoidal Tracker at RHIC  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

The primary physics task of STAR is to study the formation and characteristics of the quark-gluon plasma (QGP), a state of matter believed to exist at sufficiently high energy densities. STAR consists of several types of detectors, each specializing in detecting certain types of particles or characterizing their motion. These detectors allow final statements to be made about the collision. The gallery of STAR images makes available a small collection of event-generated images from Gold-Beam experiments, a simulation of TCP Drift, and a library of STAR instrument and construction photos. [See also DDE00093

146

ACRF Instrumentation Status: New, Current, and Future - April 2008  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

JW Voyles

2008-05-01T23:59:59.000Z

147

ACRF Instrumentation Status: New, Current, and Future July 2006  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Program Climate Research Facility instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development. New information is highlighted in blue text.

JC Liljegren

2006-07-01T23:59:59.000Z

148

ACRF Instrumentation Status: New, Current, and Future February 2009  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

JW Voyles

2009-02-15T23:59:59.000Z

149

ACRF Instrumentation Status: New, Current, and Future September 2006  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Program Climate Research Facility instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development. New information is highlighted in blue text.

JC Liljegren

2006-09-01T23:59:59.000Z

150

ARM Climate Research Facility Monthly Instrument Report May 2010  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

Voyles, JW

2010-06-21T23:59:59.000Z

151

ACRF Instrumentation Status: New, Current, and Future - November 2008  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

JW Voyles

2008-12-01T23:59:59.000Z

152

ACRF Instrumentation Status: New, Current, and Future - May 2008  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

JW Voyles

2008-05-01T23:59:59.000Z

153

ACRF Instrumentation Status: New, Current, and Future - August 2008  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

JW Voyles

2008-09-01T23:59:59.000Z

154

ARM Climate Research Facility Instrumentation Status and Information October 2009  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

JW Voyles

2009-10-01T23:59:59.000Z

155

ARM Climate Research Facility Monthly Instrument Report August 2010  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

Voyles, JW

2010-09-28T23:59:59.000Z

156

ACRF Instrumentation Status: New, Current, and Future - September 2008  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

JW Voyles

2008-10-15T23:59:59.000Z

157

ARM Climate Research Facility Instrumentation Status and Information December 2009  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

JW Voyles

2010-12-30T23:59:59.000Z

158

ARM Climate Research Facility Monthly Instrument Report June 2010  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

Voyles, JW

2010-07-13T23:59:59.000Z

159

ACRF Instrumentation Status: New, Current, and Future - July 2008  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

JW Voyles

2008-07-01T23:59:59.000Z

160

ARM Climate Research Facility Monthly Instrument Report July 2010  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

Voyles, JW

2010-08-18T23:59:59.000Z

Note: This page contains sample records for the topic "imaging instrumentation radiobiology" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

ARM Climate Research Facility Instrumentation Status and Information March 2010  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

Voyles, JW

2010-04-19T23:59:59.000Z

162

ARM Climate Research Facility Instrumentation Status and Information January 2010  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

JW Voyles

2010-02-28T23:59:59.000Z

163

ARM Climate Research Facility Instrumentation Status and Information February 2010  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

Voyles, JW

2010-03-25T23:59:59.000Z

164

ACRF Instrumentation Status: New, Current, and Future August 2006  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Program Climate Research Facility instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development. New information is highlighted in blue text.

JC Liljegren

2006-08-01T23:59:59.000Z

165

ACRF Instrumentation Status: New, Current, and Future - December 2008  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

JW Voyles

2009-01-15T23:59:59.000Z

166

ACRF Instrumentation Status: New, Current, and Future - June 2008  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

JW Voyles

2008-07-01T23:59:59.000Z

167

ARM Climate Research Facility Instrumentation Status and Information April 2010  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

Voyles, JW

2010-05-15T23:59:59.000Z

168

ACRF Instrumentation Status: New, Current, and Future March 2009  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

JW Voyles

2009-03-15T23:59:59.000Z

169

ACRF Instrumentation Status: New, Current, and Future - October 2008  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

JW Voyles

2008-10-01T23:59:59.000Z

170

ACRF Instrumentation Status: New, Current, and Future - January 2009  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

JW Voyles

2009-03-02T23:59:59.000Z

171

ARM Climate Research Facility Monthly Instrument Report September 2010  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

Voyles, JW

2010-10-18T23:59:59.000Z

172

Ultrasonic flow imaging system: A feasibility study  

SciTech Connect (OSTI)

This report examines the feasibility and potential problems in developing a real-time ultrasonic flow imaging instrument for on-line monitoring of mixed-phased flows such as coal slurries. State-of-the-art ultrasonic imaging techniques are assessed for this application. Reflection and diffraction tomographies are proposed for further development, including image-reconstruction algorithms and parallel processing systems. A conventional ultrasonic C-scan technique is used to demonstrate the feasibility of imaging the particle motion in a solid/water flow. 13 refs., 11 figs.

Sheen, S.H.; Lawrence, W.P.; Chien, H.T.; Raptis, A.C.

1991-09-01T23:59:59.000Z

173

Gamma-ray Imaging Methods  

SciTech Connect (OSTI)

In this document we discuss specific implementations for gamma-ray imaging instruments including the principle of operation and describe systems which have been built and demonstrated as well as systems currently under development. There are several fundamentally different technologies each with specific operational requirements and performance trade offs. We provide an overview of the different gamma-ray imaging techniques and briefly discuss challenges and limitations associated with each modality (in the appendix we give detailed descriptions of specific implementations for many of these technologies). In Section 3 we summarize the performance and operational aspects in tabular form as an aid for comparing technologies and mapping technologies to potential applications.

Vetter, K; Mihailescu, L; Nelson, K; Valentine, J; Wright, D

2006-10-05T23:59:59.000Z

174

Instrumentation Report No. 3: performance and reliability of instrumentation deployed for the Spent Fuel Test - Climax  

SciTech Connect (OSTI)

A demonstration of the short-term storage and subsequent retrieval of spent nuclear fuel assemblies was successfully completed at the US Department of Energy`s Nevada Test Site. Nearly 1000 instruments were deployed to monitor the temperature of rock, air, and metallic components of the test; displacements and stress changes within the rock mass; radiation dosage to personnel and to the rock; thermal energy input; characteristics of the ventilation airstream; and the operational status of the test. Careful selection, installation, calibration, and maintenance of these instruments ensured the acquisition of about 15.3 x 10{sup 6} high-quality data points. With few exceptions, the performance and reliability of the instrumentation and associated data acquisition system (DAS) were within specified acceptable limits. Details of the performance and reliability of the instrumentation are discussed in this report. 42 figs., 32 tabs.

Patrick, W.C.; Rector, N.L.; Scarafiotti, J.J.

1984-12-01T23:59:59.000Z

175

Nuclear Instruments and Methods in Physics Research A 422 (1999) 756--760 Dose mapping of inhomogeneities positioned in radiosensitive  

E-Print Network [OSTI]

Nuclear Instruments and Methods in Physics Research A 422 (1999) 756--760 Dose mapping reserved. Keywords: PAG; Dosimetry; Magnetic resonance imaging; Polyacrylamide gel; Gel dosimetry 1 0 3 1 - 6 #12;light attenuation have been proposed [4]. The ap- plications of gel dosimetry so far

Doran, Simon J.

176

Instruments aboard the ship, the Pacific Storm, ping sound waves toward the cable. The oceanographer's eyes flicker  

E-Print Network [OSTI]

Instruments aboard the ship, the Pacific Storm, ping sound waves toward the cable-pound Humboldt squid, and the sound waves, set at 38 kilohertz, bounce off the squid. An image shows up, and it attacks the tethered animal. The oceanographer screams. Fade to black. Seeing with Sound "Actually, I

Benoit-Bird, Kelly J.

177

Nuclear Instruments and Methods in Physics Research A 474 (2001) 273284 Optimal coded aperture patterns for improved SNR in nuclear  

E-Print Network [OSTI]

Nuclear Instruments and Methods in Physics Research A 474 (2001) 273­284 Optimal coded aperture patterns for improved SNR in nuclear medicine imaging Roberto Accorsia , Francesca Gasparinib , Richard C. Lanzaa, * a Nuclear Engineering Department, Massachusetts Institute of Technology, Room NW13-221, 77

Schettini, Raimondo

2001-01-01T23:59:59.000Z

178

REVIEW OF SCIENTIFIC INSTRUMENTS 82, 083301 (2011) Increasing the energy dynamic range of solid-state nuclear track detectors  

E-Print Network [OSTI]

. This allows simultaneous imaging of both high and low energy particles from the fusion reactions D + 3 He 4REVIEW OF SCIENTIFIC INSTRUMENTS 82, 083301 (2011) Increasing the energy dynamic range of solid-state nuclear track detectors using multiple surfaces A. B. Zylstra,a) H. G. Rinderknecht, N. Sinenian, M. J

179

Solar Energy Research Center Instrumentation Facility  

SciTech Connect (OSTI)

SOLAR ENERGY RESEARCH CENTER INSTRUMENTATION FACILITY The mission of the Solar Energy Research Center (UNC SERC) at the University of North Carolina at Chapel Hill (UNC-CH) is to establish a world leading effort in solar fuels research and to develop the materials and methods needed to fabricate the next generation of solar energy devices. We are addressing the fundamental issues that will drive new strategies for solar energy conversion and the engineering challenges that must be met in order to convert discoveries made in the laboratory into commercially available devices. The development of a photoelectrosynthesis cell (PEC) for solar fuels production faces daunting requirements: (1) Absorb a large fraction of sunlight; (2) Carry out artificial photosynthesis which involves multiple complex reaction steps; (3) Avoid competitive and deleterious side and reverse reactions; (4) Perform 13 million catalytic cycles per year with minimal degradation; (5) Use non-toxic materials; (6) Cost-effectiveness. PEC efficiency is directly determined by the kinetics of each reaction step. The UNC SERC is addressing this challenge by taking a broad interdisciplinary approach in a highly collaborative setting, drawing on expertise across a broad range of disciplines in chemistry, physics and materials science. By taking a systematic approach toward a fundamental understanding of the mechanism of each step, we will be able to gain unique insight and optimize PEC design. Access to cutting-edge spectroscopic tools is critical to this research effort. We have built professionally-staffed facilities equipped with the state-of the-art instrumentation funded by this award. The combination of staff, facilities, and instrumentation specifically tailored for solar fuels research establishes the UNC Solar Energy Research Center Instrumentation Facility as a unique, world-class capability. This congressionally directed project funded the development of two user facilities: TASK 1: SOLAR DEVICE FABRICATION LABORATORY DEVELOPMENT The space allocated for this laboratory was �¢����shell space�¢��� that required an upfit in order to accommodate nano-fabrication equipment in a quasi-clean room environment. This construction project (cost $279,736) met the non-federal cost share requirement of $250,000 for this award. The central element of the fabrication laboratory is a new $400,000+ stand-alone system, funded by other sources, for fabricating and characterizing photovoltaic devices, in a state-of-the-art nanofabrication environment. This congressionally directed project also included the purchase of an energy dispersive x-ray analysis (EDX) detector for a pre-existing transmission electron microscope (TEM). This detector allows elemental analysis and elemental mapping of materials used to fabricate solar energy devices which is a key priority for our research center. TASK 2: SOLAR ENERGY SPECTROSCOPY LABORATORY DEVELOPMENT (INSTRUMENTATION) This laboratory provides access to modern spectroscopy and photolysis instrumentation for characterizing devices, materials and components on time scales ranging from femtoseconds to seconds and for elucidating mechanisms. The goals of this congressionally directed project included the purchase and installation of spectroscopy and photolysis instrumentation that would substantially and meaningfully enhance the capabilities of this laboratory. Some changes were made to the list of equipment proposed in the original budget. These changes did not represent a change in scope, approach or aims of this project. All of the capabilities and experiments represented in the original budget were maintained. The outcome of this Congressionally Directed Project has been the development of world-class fabrication and spectroscopy user facilities for solar fuels research at UNC-CH. This award has provided a significant augmentation of our pre-existing instrumentation capabilities which were funded by earlier UNC SERC projects, including the Energy Frontier

Meyer, Thomas, J.; Papanikolas, John, P.

2011-11-11T23:59:59.000Z

180

Signal conditioning circuitry design for instrumentation systems.  

SciTech Connect (OSTI)

This report details the current progress in the design, implementation, and validation of the signal conditioning circuitry used in a measurement instrumentation system. The purpose of this text is to document the current progress of a particular design in signal conditioning circuitry in an instrumentation system. The input of the signal conditioning circuitry comes from a piezoresistive transducer and the output will be fed to a 250 ksps, 12-bit analog-to-digital converter (ADC) with an input range of 0-5 V. It is assumed that the maximum differential voltage amplitude input from the sensor is 20 mV with an unknown, but presumably high, sensor bandwidth. This text focuses on a specific design; however, the theory is presented in such a way that this text can be used as a basis for future designs.

Larsen, Cory A.

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "imaging instrumentation radiobiology" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

People Images  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

People Images People Images Several hundred of the 1700 U.S. scientists contributing to the LHC accelerator and experiments gathered in June 2008 in CERN's building 40 CE0252 Joel...

182

Image alignment  

DOE Patents [OSTI]

Disclosed is a method and device for aligning at least two digital images. An embodiment may use frequency-domain transforms of small tiles created from each image to identify substantially similar, "distinguishing" features within each of the images, and then align the images together based on the location of the distinguishing features. To accomplish this, an embodiment may create equal sized tile sub-images for each image. A "key" for each tile may be created by performing a frequency-domain transform calculation on each tile. A information-distance difference between each possible pair of tiles on each image may be calculated to identify distinguishing features. From analysis of the information-distance differences of the pairs of tiles, a subset of tiles with high discrimination metrics in relation to other tiles may be located for each image. The subset of distinguishing tiles for each image may then be compared to locate tiles with substantially similar keys and/or information-distance metrics to other tiles of other images. Once similar tiles are located for each image, the images may be aligned in relation to the identified similar tiles.

Dowell, Larry Jonathan

2014-04-22T23:59:59.000Z

183

Instrument development continues in Oak Ridge  

SciTech Connect (OSTI)

Peer review panels composed of 80 external scientists recently visited Oak Ridge National Laboratory (ORNL) to review almost 700 proposals for experiments on 23 instruments at the Spallation Neutron Source (SNS) and High Flux Isotope Reactor (HFIR). These were proposed for the time period from January-June 2012. About 40% of the proposals were approved for beam time and 20% were placed on an alternate list if time becomes available. The Hybrid Spectrometer HYSPEC at SNS began its commissioning in September 2011. HYSPEC is otpimized for studying low energy dynamics in single-crystal samples using a broad variety of sample environments, and is equipped with a polarization analysis capability. It is expected to be available for users on a limited basis in the second half of 2012. The detector tank of CORELLI has been installed on beamline 9 at SNS. Now that the tank is in place, banks of neutron detectors and boron carbide shielding will be installed around the interior. CORELLI is optimized to probe complex disorder in crystalline materials through diffuse scattering from single-crystal samples. It will begin commissioning in 2014. CORELLI is one of four instruments being developed under the SING II (SNS Instruments Next Generation II) project. The others are the Macromolecular Neutron Diffractometer (MANDI), the Vibrational Spectrometer (VISION, scheduled to begin commissioning in 2012), and the Time of Flight Ultra Small Angle Neutron Scattering Instrument (TOF-USANS). The single crystal neutron diffractometer IMAGINE, was deliverd to HFIR in October 2011. Preliminary testing has been carried out. IMAGINE will provide atomic resolution information on chemical, organic, metallo-organic and protein single crystals that will enable their chemical, physical and biological structure and function to be understood. This instrument will benefit scientists with interests in pharmaceuticals, minerals and other inorganic crystals, small molecules, molecular organo-metallic crystals and metal-organic frameworks (MOFs) molecular crystal structures. The quasi-Laue geometry, combined with a large solid angle detector, will enable rapid data collection from crystals with volume < 1mm{sup 1} and unit cell < 100 {angstrom}. Construction and installation of the optical system is in progress. Commissioning is expected to start in April 2012.

Ekkebus, Allen E [ORNL

2012-01-01T23:59:59.000Z

184

Instrument Series: Microscopy Aberration-Corrected  

E-Print Network [OSTI]

, and material defects Chemistry ­ understanding particle surface interactions, atomic-level structure-tilt Crystallographic and Tomographic Analysis Ì Silicon-Lithium [Si(Li)] X-ray EDS Ì Cryogenic Imaging Capability Ì

185

Instrumentation for multiaxial mechanical testing of inhomogeneous elastic membranes  

E-Print Network [OSTI]

This thesis presents the design, development, and construction of an instrument for biaxial mechanical testing of inhomogeneous elastic membranes. The instrument incorporates an arrangement of linear motion stages for ...

Herrmann, Ariel Marc

2006-01-01T23:59:59.000Z

186

CU-LASP Test Facilities ! and Instrument Calibration Capabilities"  

E-Print Network [OSTI]

­ Star tracker ­ Solar position sensors ­ Test & calibration applications ­ End-to-end instrument;Total Solar Irradiance Radiometer Facility (TRF) · Total Solar Irradiance (TSI) instrument calibrations

Mojzsis, Stephen J.

187

Implementation of instruments and facilities at the SGP CART site  

SciTech Connect (OSTI)

This report discusses the installation of instruments and trailers at the southern Great Plains Clouds and Radiation Testbed site.

Sisterson, D.L.; Wesely, M.L.

1994-02-01T23:59:59.000Z

188

SP100i Syringe Pump WORLD PRECISION INSTRUMENTS 15  

E-Print Network [OSTI]

SP100i Syringe Pump WORLD PRECISION INSTRUMENTS 15 INSTRUCTION MANUAL Serial No._____________________ 8/94 World Precision Instruments, Inc. SP100i Syringe Pump Digital Infusion Syringe Pump #12;SP100i Syringe Pump WORLD PRECISION INSTRUMENTS 1 Contents GENERAL DESCRIPTION

Kleinfeld, David

189

MHD power plant instrumentation and control  

SciTech Connect (OSTI)

The Electric Power Research Institute (EPRI) has awarded a contract to the MHD Development Corporation (MDC) to develop instrumentation and control requirements and strategies for commercial MHD power plants. MDC subcontracted MSE to do the technical development required. MSE is being assisted by Montana State University (MSU) for the topping cycle development. A computer model of a stand-alone MHD/steam plant is being constructed. The plant is based on the plant design set forth in the MDC proposal to the Federal Clean Coal Technology 5 solicitation. It consists of an MHD topping plant, a Heat Recovery Seed Recovery (HRSR) plant, and a steam turbo-generator. The model is based on the computer code used for a study of the Corette plant retrofitted with an MHD plant. Additional control strategies, based on MHD testing results and current steam bottoming plant control data, will be incorporated. A model will be devised and implemented for automatic control of the plant. Requirements regarding instrumentation and actuators will be documented. Instrumentation and actuators that are not commercially available will be identified. The role and desired characteristics of an expert system in the automated control scheme is being investigated. Start-up and shutdown procedures will be studied and load change dynamic performance will be evaluated. System response to abnormal topping cycle and off-design system operation will be investigated. This includes use of MHD topping cycle models which couple gasdynamic and electrical behavior for the study of controlling of the MHD topping cycle. A curvefitter, which uses cubic Hermitian spline interpolation functions in as many as five dimensions, allows much more accurate reproduction of nonlinear, multidimensional functions. This project will be the first to investigate plant dynamics and control using as many as seven independent variables or control inputs to the MHD topping cycle.

Lofftus, D.; Rudberg, D. [MSE Inc., Butte, MT (United States); Johnson, R.; Hammerstrom, D. [Montana State Univ., Bozeman, MT (United States)

1993-12-31T23:59:59.000Z

190

Beam instrumentation for the Tevatron Collider  

SciTech Connect (OSTI)

The Tevatron in Collider Run II (2001-present) is operating with six times more bunches and many times higher beam intensities and luminosities than in Run I (1992-1995). Beam diagnostics were crucial for the machine start-up and the never-ending luminosity upgrade campaign. We present the overall picture of the Tevatron diagnostics development for Run II, outline machine needs for new instrumentation, present several notable examples that led to Tevatron performance improvements, and discuss the lessons for future colliders.

Moore, Ronald S.; Jansson, Andreas; Shiltsev, Vladimir; /Fermilab

2009-10-01T23:59:59.000Z

191

Curtis Instruments Inc | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublic Utilities Address: 160Benin:EnergyWisconsin:2003)Crowley County,Curran, Illinois:Instruments Inc Jump to:

192

Licenses Available in Analytical Instrumentation | ORNL  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth7-1D: VegetationEquipment Surfaces and Interfaces Sample6, 2011 LawrenceE CAnalytical Instrumentation SHARE

193

ARM - Campaign Instrument - 5mm-mwr  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary)morphinanInformation Desert SouthwestTechnologies |NovemberARMContactsARMFacilitiesCERAgovInstruments5mm-mwr

194

Microfabricated instrument for tissue biopsy and analysis  

DOE Patents [OSTI]

A microfabricated biopsy/histology instrument which has several advantages over the conventional procedures, including minimal specimen handling, smooth cutting edges with atomic sharpness capable of slicing very thin specimens (approximately 2 .mu.m or greater), micro-liter volumes of chemicals for treating the specimens, low cost, disposable, fabrication process which renders sterile parts, and ease of use. The cutter is a "cheese-grater" style design comprising a block or substrate of silicon and which uses anisotropic etching of the silicon to form extremely sharp and precise cutting edges. As a specimen is cut, it passes through the silicon cutter and lies flat on a piece of glass which is bonded to the cutter. Microchannels are etched into the glass or silicon substrates for delivering small volumes of chemicals for treating the specimen. After treatment, the specimens can be examined through the glass substrate. For automation purposes, microvalves and micropumps may be incorporated. Also, specimens in parallel may be cut and treated with identical or varied chemicals. The instrument is disposable due to its low cost and thus could replace current expensive microtome and histology equipment.

Krulevitch, Peter A. (Pleasanton, CA); Lee, Abraham P. (Walnut Creek, CA); Northrup, M. Allen (Berkeley, CA); Benett, William J. (Livermore, CA)

1999-01-01T23:59:59.000Z

195

Accommodating subject and instrument variations in spectroscopic determinations  

DOE Patents [OSTI]

A method and apparatus for measuring a biological attribute, such as the concentration of an analyte, particularly a blood analyte in tissue such as glucose. The method utilizes spectrographic techniques in conjunction with an improved instrument-tailored or subject-tailored calibration model. In a calibration phase, calibration model data is modified to reduce or eliminate instrument-specific attributes, resulting in a calibration data set modeling intra-instrument or intra-subject variation. In a prediction phase, the prediction process is tailored for each target instrument separately using a minimal number of spectral measurements from each instrument or subject.

Haas, Michael J. (Albuquerque, NM); Rowe, Robert K. (Corrales, NM); Thomas, Edward V. (Albuquerque, NM)

2006-08-29T23:59:59.000Z

196

Computing Images  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Computing Images The interior of an automated tape library in Brookhaven's RHIC and ATLAS Computing Facility. Brookhaven engineers in the RHIC and ATLAS Computing Facility....

197

CIWS-FW: a Customizable InstrumentWorkstation Software Framework for instrument-independent data handling  

E-Print Network [OSTI]

The CIWS-FW is aimed at providing a common and standard solution for the storage, processing and quick look at the data acquired from scientific instruments for astrophysics. The target system is the instrument workstation either in the context of the Electrical Ground Support Equipment for space-borne experiments, or in the context of the data acquisition system for instrumentation. The CIWS-FW core includes software developed by team members for previous experiments and provides new components and tools that improve the software reusability, configurability and extensibility attributes. The CIWS-FW mainly consists of two packages: the data processing system and the data access system. The former provides the software components and libraries to support the data acquisition, transformation, display and storage in near real time of either a data packet stream and/or a sequence of data files generated by the instrument. The latter is a meta-data and data management system, providing a reusable solution for the...

Conforti, Vito; Bulgarelli, Andrea; Gianotti, Fulvio; Franceschi, Enrico; Nicastro, Luciano; Zoli, Andrea; Dadina, Mauro; Smart, Ricky; Morbidelli, Roberto; Frailis, Marco; Sartor, Stefano; Zacchei, Andrea; Lodi, Marcello; Cirami, Roberto; Pasian, Fabio

2014-01-01T23:59:59.000Z

198

1) Start the Instrument and Software 2 1.1 Start the Instrument 2  

E-Print Network [OSTI]

adhesive film. ColorofLeftLED ColorofRightLED StatusofInstrument Orange *flashing* Orange *flashing on the computer workstation (if it is not already on). 2. Login to Windows. a. User name: operator b. Password: LC Window will appear. Click on New Ex- periment. 2. The software will open the New Experiment Window

Gruner, Daniel S.

199

FY09 Advanced Instrumentation and Active Interrogation Research for Safeguards  

SciTech Connect (OSTI)

Multiple small-scale projects have been undertaken to investigate advanced instrumentation solutions for safeguard measurement challenges associated with advanced fuel cycle facilities and next-generation fuel reprocessing installations. These activities are in support of the U.S. Department of Energy's Fuel Cycle Research and Development program and its Materials Protection, Accounting, and Control for Transmutation (MPACT) campaign. 1) Work was performed in a collaboration with the University of Michigan (Prof. Sara Pozzi, co-PI) to investigate the use of liquid-scintillator radiation detectors for assaying mixed-oxide (MOX) fuel, to characterize its composition and to develop advanced digital pulse-shape discrimination algorithms for performing time-correlation measurements in the MOX fuel environment. This work included both simulations and experiments and has shown that these techniques may provide a valuable approach for use within advanced safeguard measurement scenarios. 2) Work was conducted in a collaboration with Oak Ridge National Laboratory (Dr. Paul Hausladen, co-PI) to evaluate the strengths and weaknesses of the fast-neutron coded-aperture imaging technique for locating and characterizing fissile material, and as a tool for performing hold-up measurements in fissile material handling facilities. This work involved experiments at Idaho National Laboratory, using MOX fuel and uranium metal, in both passive and active interrogation configurations. A complete analysis has not yet been completed but preliminary results suggest several potential uses for the fast neutron imaging technique. 3) Work was carried out to identify measurement approaches for determining nitric acid concentration in the range of 1 – 4 M and beyond. This work included laboratory measurements to investigate the suitability of prompt-gamma neutron activation analysis for this measurement and product reviews of other commercial solutions. Ultrasonic density analysis appears to be the best candidate technology for determining nitric acid concentrations but the PGNAA approach may also be applicable. 4) Work was also carried out to begin investigating the use of remote UV imaging to detect air-ionization induced by alpha particle emission from plutonium. This approach has been shown elsewhere as a useful tool for detecting and quantifying plutonium contamination and has the potential of providing a unique and powerful approach for quantifying hold-up in reprocessing facilities. Based on these simple scoping experiments the potential far-reaching capabilities of the measurement are clear.

D. L. Chichester; S. A. Pozzi; E. H. Seabury; J. L. Dolan; M. Flaska; J. T. Johnson; S. M. Watson; J. Wharton

2009-08-01T23:59:59.000Z

200

SRS delayed neutron instruments for safeguards measurements  

SciTech Connect (OSTI)

Six analytical systems measuring delayed neutrons have been used for safeguards measurements at the Savannah River Site (SRS). A predecessor, the 252Cf Activation Analysis Facility installed at the Savannah River Technology Center (formally SR Laboratory) has been used since 1974 to analyze small samples, measuring both delayed neutrons and gammas. The six shufflers, plus one currently being fabricated, were developed, designed and fabricated by the LANL N-1 group. These shufflers have provided safeguards measurements of product (2 each), in-process scrap (2 each plus a conceptual replacement) and process waste (2 each plus one being fabricated). One shuffler for scrap assay was the first shuffler to be installed (1978) in a process. Another (waste) was the first installed in a process capable of assaying barrels. A third (waste) is the first pass-through model and a fourth (product) is the most precise ({+-}.12%) and accurate NDA instrument yet produced.

Studley, R.V. [Westinghouse SRC, Aiken, SC (United States)

1993-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "imaging instrumentation radiobiology" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Microfabricated instrument for tissue biopsy and analysis  

DOE Patents [OSTI]

A microfabricated biopsy/histology instrument which has several advantages over the conventional procedures, including minimal specimen handling, smooth cutting edges with atomic sharpness capable of slicing very thin specimens (approximately 2 .mu.m or greater), micro-liter volumes of chemicals for treating the specimens, low cost, disposable, fabrication process which renders sterile parts, and ease of use. The cutter is a "cheese-grater" style design comprising a block or substrate of silicon and which uses anisotropic etching of the silicon to form extremely sharp and precise cutting edges. As a specimen is cut, it passes through the silicon cutter and lies flat on a piece of glass which is bonded to the cutter. Microchannels are etched into the glass or silicon substrates for delivering small volumes of chemicals for treating the specimen. After treatment, the specimens can be examined through the glass substrate.

Krulevitch, Peter A. (Pleasanton, CA); Lee, Abraham P. (Walnut Creek, CA); Northrup, M. Allen (Berkeley, CA); Benett, William J. (Livermore, CA)

2001-01-01T23:59:59.000Z

202

Highly damped kinematic coupling for precision instruments  

DOE Patents [OSTI]

A highly damped kinematic coupling for precision instruments. The kinematic coupling provides support while causing essentially no influence to its nature shape, with such influences coming, for example, from manufacturing tolerances, temperature changes, or ground motion. The coupling uses three ball-cone constraints, each combined with a released flexural degree of freedom. This arrangement enables a gain of higher load capacity and stiffness, but can also significantly reduce the friction level in proportion to the ball radius divided by the distance between the ball and the hinge axis. The blade flexures reduces somewhat the stiffness of the coupling and provides an ideal location to apply constrained-layer damping which is accomplished by attaching a viscoelastic layer and a constraining layer on opposite sides of each of the blade flexures. The three identical ball-cone flexures provide a damped coupling mechanism to kinematically support the projection optics system of the extreme ultraviolet lithography (EUVL) system, or other load-sensitive apparatus.

Hale, Layton C. (Livermore, CA); Jensen, Steven A. (Livermore, CA)

2001-01-01T23:59:59.000Z

203

Assessing the local windfield with instrumentation  

SciTech Connect (OSTI)

This report concerns the development and testing of a technique for the initial screening and evaluation of potential sites for wind-energy conversion systems (WECS). The methodology was developed through a realistic siting exercise. The siting exercise involved measurements of winds along the surface and winds aloft using a relatively new instrument system, the Tethered Aerodynamic Lifting Anemometer (TALA) kite; notation of ecological factors such as vegetation flagging, soil erosion and site exposure, and verification of an area best suited for wind-energy development by establishing and maintaining a wind monitoring network. The siting exercise was carried out in an approximately 100-square-mile region of the Tehachapi Mountains of Southern California. The results showed that a comprehensive site survey involving field measurements, ecological survey, and wind-monitoring can be an effective tool for preliminary evaluation of WECS sites.

Zambrano, T.G.

1980-10-01T23:59:59.000Z

204

DOE Fundamentals Handbook: Instrumentation and Control, Volume 2  

SciTech Connect (OSTI)

The Instrumentation and Control Fundamentals Handbook personnel, and the technical staff facility operating contractors provide operators, maintenance personnel, and the technical staff with the necessary fundamentals training to ensure a basic understanding of instrumentation and control systems. The handbook includes information on temperature, pressure, flow, and level detection systems; position indication systems; process control systems; and radiation detection principles. This information will provide personnel with an understanding of the basic operation of various types of DOE nuclear facility instrumentation and control systems.

Not Available

1992-06-01T23:59:59.000Z

205

DOE Fundamentals Handbook: Instrumentation and Control, Volume 1  

SciTech Connect (OSTI)

The Instrumentation and Control Fundamentals Handbook was developed to assist nuclear facility operating contractors provide operators, maintenance personnel, and the technical staff with the necessary fundamentals training to ensure a basic understanding of instrumentation and control systems. The handbook includes information on temperature, pressure, flow, and level detection systems; position indication systems; process control systems; and radiation detection principles. This information will provide personnel with an understanding of the basic operation of various types of DOE nuclear facility instrumentation and control systems.

Not Available

1992-06-01T23:59:59.000Z

206

Radiation Protection Instrument Manual, Revision 1, PNL-MA-562  

SciTech Connect (OSTI)

PNL-MA-562 This manual provides specific information for operating and using portable radiological monitoring instruments available for use on the Hanford Site.

Johnson, Michelle Lynn

2009-09-23T23:59:59.000Z

207

automatic stapling instrument: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

MUSICAL INSTRUMENT DETECTOR BY USING EVOLUTIONARY LEARNING METHOD Yoshiyuki Kobayashi SONY Corporation, Japan Yoshiyuki.Kobayashi@jp.sony.com ABSTRACT This paper presents a novel...

208

adaptive nonparametric instrumental: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

both selects Faraway, Julian 27 Spanish Version of the Sport Satisfaction Instrument (SSI) Adapted to Physical Education CiteSeer Summary: The objective of this research was to...

209

Tuesday, March 14, 2006 POSTER SESSION I: INSTRUMENT FACILITIES  

E-Print Network [OSTI]

-of-the-art instrument and the research that we will do with it. Kohout T. Elbra T. Pesonen L. J. Schnabl P. Slechta S

Rathbun, Julie A.

210

QAS 2.4 Instrument Calibration 5/26/95  

Broader source: Energy.gov [DOE]

The objective of this surveillance is to evaluate the implementation of the contractor's program to routinely calibrate instruments, alarms, and sensors.  The Facility Representative observes...

211

activation instrumental analysis: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

car electronics industry. There are currently many electronic systems improving the safety Wieringa, Roel 17 Runtime Instrumentation for Precise Flow-Sensitive Type Analysis...

212

Advances in nuclear instrumentation for safeguards  

SciTech Connect (OSTI)

This paper describes detectors, instrumentation, and analytical methods under development to address the above issues. The authors will describe work underway on room-temperature semiconductors including attempts to model the response of these detectors to improve spectrum analysis procedures and detector design. Computerized tomography is used in many medical and industrial applications; they are developing both gamma-ray and neutron tomography for improved measurements of waste and direct-use materials. Modern electronics and scintillation detectors should permit the development of fast neutron coincidence detectors with dramatically improved signal-to-noise ratios. For active measurements, they are studying several improved neutron sources, including a high-fluence, plasma-based, d-t generator. New analysis tools from information theory may permit one to better combine data from different measurement systems. This paper attempts to briefly describe a range of new sensors, electronics, and data analysis methods under study at Los Alamos and other laboratories to promote discussion of promising technology that they may bring to bear on these important global issues.

Prettyman, T.H.; Reilly, T.D.; Miller, M.C.; Hollas, C.L.; Pickrell, M.M.; Prommel, J.M.; Dreicer, J.S.

1996-12-31T23:59:59.000Z

213

X-Ray Nanoimaging: Instruments and Methods  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsrucLasDelivered energy consumption byAbout SRNL Home SRNL main campusMore thanX-Ray Imaging of

214

X-Ray Nanoimaging: Instruments and Methods  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsrucLasDelivered energy consumption byAbout SRNL Home SRNL main campusMore thanX-Ray Imaging ofX-Ray

215

Software optimization for electrical conductivity imaging in polycrystalline diamond cutters  

SciTech Connect (OSTI)

We previously reported on an electrical conductivity imaging instrument developed for measurements on polycrystalline diamond cutters. These cylindrical cutters for oil and gas drilling feature a thick polycrystalline diamond layer on a tungsten carbide substrate. The instrument uses electrical impedance tomography to profile the conductivity in the diamond table. Conductivity images must be acquired quickly, on the order of 5 sec per cutter, to be useful in the manufacturing process. This paper reports on successful efforts to optimize the conductivity reconstruction routine, porting major portions of it to NVIDIA GPUs, including a custom CUDA kernel for Jacobian computation.

Bogdanov, G.; Ludwig, R. [Department of Electrical and Computer Engineering, Worcester Polytechnic Institute, 100 Institute Rd, Worcester, MA 01609 (United States); Wiggins, J.; Bertagnolli, K. [US Synthetic, 1260 South 1600 West, Orem, UT 84058 (United States)

2014-02-18T23:59:59.000Z

216

Radiobiological Laboratory Beaufort, N.C.  

E-Print Network [OSTI]

accumulation by mummichog from food and water .·· Methods ·············.·.······.... Results .·....·······.·.·..·· · ·..·· Accumulation of cerium 144 from food by Fundulus Methods .······ Results .···..·· Retention and translocation of radiation on marine organisms. · 28 Blood characteristics of irradiated and unirradiated fish. 29 Effect

217

Radiobiological modelling with MarCell software  

SciTech Connect (OSTI)

Jones introduced a bone marrow radiation cell kinetics model with great potential for application in the fields of health physics, radiation research, and medicine. However, until recently, only the model developers have been able to apply it because of the complex array of biological and physical assignments needed for evaluation of a particular radiation exposure protocol. The purpose of this article is to illustrate the use of MarCell (MARrow CELL Kinetics) software for MS-DOS, a user-friendly computer implementation of that mathematical model that allows almost anyone with an elementary knowledge of radiation physics and/or medical procedures to apply the model. A hands-on demonstration of the software will be given by guiding the user through evaluation of a medical total body irradiation protocol and a nuclear fallout scenario. A brief overview of the software is given in the Appendix.

Hasan, J.S.; Jones, T.D.

1996-10-01T23:59:59.000Z

218

7-GeV Advanced Photon Source Instrumentation Initiative conceptual design report  

SciTech Connect (OSTI)

In this APS Instrumentation Initiative, 2.5-m-long and 5-m-long insertion-device x-ray sources will be built on 9 straight sections of the APS storage ring, and an additional 9 bending-magnet sources will also be put in use. The front ends for these 18 x-ray sources will be built to contain and safeguard access to these bright x-ray beams. In addition, funds will be provided to build state-of-the-art insertion-device beamlines to meet scientific and technological research demands well into the next century. This new initiative will also include four user laboratory modules and a special laboratory designed to meet the x-ray imaging research needs of the users. The Conceptual Design Report (CDR) for the APS Instrumentation Initiative describes the scope of all the above technical and conventional construction and provides a detailed cost and schedule for these activities. According to these plans, this new initiative begins in FY 1994 and ends in FY 1998. The document also describes the preconstruction R D plans for the Instrumentation Initiative activities and provides the cost estimates for the required R D.

Not Available

1992-12-01T23:59:59.000Z

219

7-GeV Advanced Photon Source Instrumentation Initiative conceptual design report  

SciTech Connect (OSTI)

In this APS Instrumentation Initiative, 2.5-m-long and 5-m-long insertion-device x-ray sources will be built on 9 straight sections of the APS storage ring, and an additional 9 bending-magnet sources will also be put in use. The front ends for these 18 x-ray sources will be built to contain and safeguard access to these bright x-ray beams. In addition, funds will be provided to build state-of-the-art insertion-device beamlines to meet scientific and technological research demands well into the next century. This new initiative will also include four user laboratory modules and a special laboratory designed to meet the x-ray imaging research needs of the users. The Conceptual Design Report (CDR) for the APS Instrumentation Initiative describes the scope of all the above technical and conventional construction and provides a detailed cost and schedule for these activities. According to these plans, this new initiative begins in FY 1994 and ends in FY 1998. The document also describes the preconstruction R&D plans for the Instrumentation Initiative activities and provides the cost estimates for the required R&D.

Not Available

1992-12-01T23:59:59.000Z

220

Hand-held pulse-train-analysis instrument  

SciTech Connect (OSTI)

A portable hand-held pulse-train-analysis instrument uses a number-oriented microprocessor sequenced by a single component microprocessor. The incorporation of new CMOS integrated circuits makes possible complex analysis in a small, easily operated, battery-powered unit. The instrument solves an immediate problem with threshold setting of plastic scintillators and promises numerous other applications.

Nixon, K.V.; Garcia, C.

1982-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "imaging instrumentation radiobiology" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Brookhaven National Laboratory meteorological services instrument calibration plan and procedures  

SciTech Connect (OSTI)

This document describes the Meteorological Services (Met Services) Calibration and Maintenance Schedule and Procedures, The purpose is to establish the frequency and mechanism for the calibration and maintenance of the network of meteorological instrumentation operated by Met Services. The goal is to maintain the network in a manner that will result in accurate, precise and reliable readings from the instrumentation.

Heiser .

2013-02-16T23:59:59.000Z

222

The Cosmic Origins Spectrograph: A Hubble Replacement Instrument  

E-Print Network [OSTI]

The Cosmic Origins Spectrograph: A Hubble Replacement Instrument for the 2002 Reservicing Mission Origins Spectrograph (COS) has recently been selected as a replacement instrument for the Hubble Space Telescope. Installation is scheduled for late 2002, replacing COSTAR, which at that time will be unnecessary

Colorado at Boulder, University of

223

PNWD-SA-6893 Instrumenting the Intelligence Analysis Process  

E-Print Network [OSTI]

PNWD-SA-6893 Instrumenting the Intelligence Analysis Process Ernest Hampson Paula Cowley PresentedLean, VA, USA Battelle Memorial Institute #12;Instrumenting the Intelligence Analysis Process Ernest process Abstract The Advanced Research and Development Activity initiated the Novel Intelligence from

224

Evaluation of Instrumentation and Dynamic Thermal Ratings for Overhead Lines  

SciTech Connect (OSTI)

In 2010, a project was initiated through a partnership between the Department of Energy (DOE) and the New York Power Authority (NYPA) to evaluate EPRI?s rating technology and instrumentation that can be used to monitor the thermal states of transmission lines and provide the required real-time data for real-time rating calculations. The project included the installation and maintenance of various instruments at three 230 kV line sites in northern New York. The instruments were monitored, and data collection and rating calculations were performed for about a three year period.

Phillips, A.

2013-01-31T23:59:59.000Z

225

Temporal Pointing Variations of The Solar Dynamics Observatory's HMI and AIA Instruments on Sub-Weekly Time Scales  

E-Print Network [OSTI]

Achieving sub-arcsecond co-registration across varying time-lines of multi-wavelength and instrument images is not trivial, and requires accurate characterization of instrument pointing jitter. In this work we have investigated internal pointing errors, on daily and yearly time-scales, occurring across the \\textit{Solar Dynamics Observatory}'s (SDO) {\\it Atmospheric Imaging Assembly} (AIA) and { \\it Helioseismic Magnetic Imager} (HMI). Using cross-correlation techniques on AIA 1700\\,{\\AA} passband and HMI line-of-sight (LOS) magnetograms, from three years of observational image pairs at approximately three day intervals, internal pointing errors are quantified. Pointing variations of $\\pm$\\,0.26$\\arcsec$ (jitter limited) and $\\pm$\\,0.50$\\arcsec$ in the solar East-West ($x$) and North-South ($y$) directions, respectively, are measured. AIA observations of the Venus June 2012 transit are used to measure existing coalignment offsets in all passbands. We find AIA passband pointing variations are $$\\,$=$\\, 1.10$\\a...

Orange, N Brice; Chesny, David L; Patel, Maulik; Champey, Patrick; Hesterly, Katie; Anthony, Dylan; Treen, Robert

2015-01-01T23:59:59.000Z

226

ARM Climate Research Facility Quarterly Instrument Report Fourth Quarter: October 1–December 30, 2010  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

Voyles, JW

2011-01-17T23:59:59.000Z

227

ACRF Instrumentation Status: New, Current, and Future November-December 2006  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Program Climate Research Facility instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

JC Liljegren

2006-12-01T23:59:59.000Z

228

Atmospheric Radiation Measurement Climate Research Facility (ACRF Instrumentation Status: New, Current, and Future)  

SciTech Connect (OSTI)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

JW Voyles

2008-01-30T23:59:59.000Z

229

The localization of instrumental learning within the spinal cord  

E-Print Network [OSTI]

Spinal neurons of surgically transected rats can support a simple form of instrumental learning. Rats learn to maintain leg flexion as a response to shock. The present experiments localized the region of the spinal cord that mediates this learning...

Liu, Grace Alexandra Tsu-Chi

2013-02-22T23:59:59.000Z

230

Instrumenting Buildings to Determine Retrofit Savings: Murphy's Law Strikes Again  

E-Print Network [OSTI]

&M University. Metering typically includes monitoring for the whole-building electric load, chilled and hot water thermal loads and selected submetered electrical loads. The emphasis of the lessons learned was on the instrumentation used and installation...

O'Neal, D. L.; Bryant, J.; Carlson, K.

1998-01-01T23:59:59.000Z

231

Instant Profiling: Instrumentation Sampling for Profiling Datacenter Applications  

E-Print Network [OSTI]

Instant Profiling: Instrumentation Sampling for Profiling Datacenter Applications Hyoun Kyu Cho Profile-guided optimization possesses huge potential to save costs for datacenters. Hardware performance programmers find code regions to optimize by monitoring datacenter applications continuously on live traffic

Tomkins, Andrew

232

Hybrid percussion : extending physical instruments using sampled acoustics  

E-Print Network [OSTI]

This thesis presents a system architecture for creating hybrid digital-acoustic percussion instruments by combining extensions of existing signal processing techniques with specially-designed semi-acoustic physical ...

Aimi, Roberto Mario, 1973-

2007-01-01T23:59:59.000Z

233

Internship experience at Texas Instruments: the internship report  

E-Print Network [OSTI]

This report presents a survey of the author's internship experience with Texas Instruments from November 1980 to November 1981. The internship was spent in the Advanced Research and Development Division of the Digital Systems Group...

Glover, Kerry Cloyce, 1954-

2013-03-13T23:59:59.000Z

234

PLC & DTAM Software Programs for Pumping Instrumentation & Control Skid P  

SciTech Connect (OSTI)

This document describes the software programs for the programmable logic controller and the datable access module for pumping instrumentation and control skid P. The appendices contains copies of the printouts of these software programs.

HORNER, T.M.

2001-07-19T23:59:59.000Z

235

Historical perspective of innovation in electronic payment instruments  

E-Print Network [OSTI]

Electronic Payment Instruments have seen unprecedented innovation in the past XX-th century. Most of this innovation was made possible by advances in information and communication technology. Advances in ICT paired with ...

Pogor, Iulian

2011-01-01T23:59:59.000Z

236

Imaging bolometer  

DOE Patents [OSTI]

Radiation-hard, steady-state imaging bolometer. A bolometer employing infrared (IR) imaging of a segmented-matrix absorber of plasma radiation in a cooled-pinhole camera geometry is described. The bolometer design parameters are determined by modeling the temperature of the foils from which the absorbing matrix is fabricated by using a two-dimensional time-dependent solution of the heat conduction equation. The resulting design will give a steady-state bolometry capability, with approximately 100 Hz time resolution, while simultaneously providing hundreds of channels of spatial information. No wiring harnesses will be required, as the temperature-rise data will be measured via an IR camera. The resulting spatial data may be used to tomographically investigate the profile of plasmas.

Wurden, Glen A. (Los Alamos, NM)

1999-01-01T23:59:59.000Z

237

Imaging bolometer  

DOE Patents [OSTI]

Radiation-hard, steady-state imaging bolometer is disclosed. A bolometer employing infrared (IR) imaging of a segmented-matrix absorber of plasma radiation in a cooled-pinhole camera geometry is described. The bolometer design parameters are determined by modeling the temperature of the foils from which the absorbing matrix is fabricated by using a two-dimensional time-dependent solution of the heat conduction equation. The resulting design will give a steady-state bolometry capability, with approximately 100 Hz time resolution, while simultaneously providing hundreds of channels of spatial information. No wiring harnesses will be required, as the temperature-rise data will be measured via an IR camera. The resulting spatial data may be used to tomographically investigate the profile of plasmas. 2 figs.

Wurden, G.A.

1999-01-19T23:59:59.000Z

238

Increasing accuracy in image-guided robotic surgery through tip tracking and model-based flexion correction  

E-Print Network [OSTI]

Robot assistance can enhance minimally invasive image-guided surgery, but flexion of the thin surgical instrument shaft impairs accurate control by creating errors in the kinematic model. Two controller enhancements that ...

Beasley, Ryan A.

239

Advanced Instrumentation, Information, and Control Systems Technologies Technical Program Plan  

SciTech Connect (OSTI)

Reliable instrumentation, information, and control (II&C) systems technologies are essential to ensuring safe and efficient operation of the U.S. light water reactor (LWR) fleet. These technologies affect every aspect of nuclear power plant (NPP) and balance-of-plant operations. In 1997, the National Research Council conducted a study concerning the challenges involved in modernization of digital instrumentation and control systems in NPPs. Their findings identified the need for new II&C technology integration.

Bruce Hallbert

2012-09-01T23:59:59.000Z

240

Digital configurable instrument for emulation of signals from radiation detectors  

SciTech Connect (OSTI)

The paper presents a digital instrument characterized by a specially designed architecture that is able to emulate in real time signals from a generic radiation detection system. The instrument is not a pulse generator of recorded shapes but a synthesizer of random pulses compliant to programmable statistics for height and starting time of events. Completely programmable procedures for emulation of noise, disturbances, and reference level variation are implemented.

Abba, A.; Caponio, F.; Geraci, A. [Politecnico di Milano, Department of Electronics, Information and Bioengineering-DEIB, Milan 20133 (Italy)] [Politecnico di Milano, Department of Electronics, Information and Bioengineering-DEIB, Milan 20133 (Italy)

2014-01-15T23:59:59.000Z

Note: This page contains sample records for the topic "imaging instrumentation radiobiology" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Instrumentation and control for fossil-energy processes  

SciTech Connect (OSTI)

The 1982 symposium on instrumentation and control for fossil energy processes was held June 7 through 9, 1982, at Adam's Mark Hotel, Houston, Texas. It was sponsored by the US Department of Energy, Office of Fossil Energy; Argonne National Laboratory; and the Society for Control and Instrumentation of Energy Processes. Fifty-two papers have been entered individually into EDB and ERA; eleven papers had been entered previously from other sources. (LTN)

Not Available

1982-09-01T23:59:59.000Z

242

EUV multilayer coatings for the Atmospheric Imaging Assembly instrument aboard the Solar Dynamics Observatory  

SciTech Connect (OSTI)

Multilayer coatings for the 7 EUV channels of the AIA have been developed and completed successfully on all AIA flight mirrors. Mo/Si coatings (131, 171, 193.5, 211 {angstrom}) were deposited at Lawrence Livermore National Laboratory (LLNL). Mg/SiC (304, 335 {angstrom}) and Mo/Y (94 {angstrom}) coatings were deposited at Columbia University. EUV reflectance of the 131/335 {angstrom}, 171 {angstrom}, 193.5/211 {angstrom} primary and secondary flight mirrors and the 94/304 {angstrom} secondary flight mirror was measured at beamline 6.3.2. of the Advanced Light Source (ALS) at LBNL. EUV reflectance of the 94/304 {angstrom} primary and secondary flight mirrors was measured at beamline X24C of the National Synchrotron Light Source (NSLS) at Brookhaven National Lab. Preliminary EUV reflectance measurements of the 94, 304 and 335 {angstrom} coatings were performed with a laser plasma source reflectometer located at Columbia University. Prior to multilayer coating, Atomic Force Microscopy (AFM) characterization and cleaning of all flight substrates was performed at LLNL.

Soufli, R; Windt, D L; Robinson, J C; Baker, S L; Spiller, E; Dollar, F J; Aquila, A L; Gullikson, E M; Kjonrattanawanich, B; Seely, J F; Golub, L

2006-02-09T23:59:59.000Z

243

Biomedical Instrumentation and Imaging at TJNAF | U.S. DOE Office...  

Office of Science (SC) Website

Nuclear Science Advisory Committee (NSAC) News & Resources Contact Information Nuclear Physics U.S. Department of Energy SC-26Germantown Building 1000 Independence...

244

The Instrumental Function of the X-ray Imaging Crystal Spectrometer on Alcator C-Mod  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear SecurityTensile Strain Switched Ferromagnetism in Layered NbS2 and NbSe2DifferentTheInforum LIFT ModelThe Inside

245

Biomedical Instrumentation and Imaging at TJNAF | U.S. DOE Office of  

Office of Science (SC) Website

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear SecurityTensile Strain Switched5 IndustrialIsadore Perlman,BiosScience(SC) AprilScienceReportsOctober 1-2,Science

246

Sub-Millimetre Wave Sub-Harmonically Pumped Image-Rejection Schottky Mixers for STEAM-R  

E-Print Network [OSTI]

Sub-Millimetre Wave Sub-Harmonically Pumped Image- Rejection Schottky Mixers for STEAM-R S. P. Rea = 343.5 - 355.5 GHz switch The PREMIER Mission The STEAM-R Instrument PREMIER (PRocess Exploration-sounder (MWLS) on the same satellite platform. The MWLS is the latest iteration of the STEAM-R instrument

247

New Frontiers in Solar Physics: Broadband Imaging Spectroscopy with the  

E-Print Network [OSTI]

, the solar panel of the AASC recommended an integrated suite of instrumentation designed to meetNew Frontiers in Solar Physics: Broadband Imaging Spectroscopy with the Frequency Agile Solar and other astrophysical objects and processes. Outstanding problems in solar physics include the magnetic

248

Highly Integrated, High Performance, Imaging Detector Systems Using  

E-Print Network [OSTI]

performance - Susceptible to bulk radiation damage so radiation"soft" · CCDs are large capacitance devices so.3 volt) operation - Fast, digital readout - More radiation hard than CCDs · Strong commercial, biomedical Miniaturized imaging instruments Space telescopes - Spacecraft Star trackers Optical navigation Optical comm

Fossum, Eric R.

249

Supercontinuum Stimulated Emission Depletion Fluorescence Lifetime Imaging  

SciTech Connect (OSTI)

Supercontinuum (SC) stimulated emission depletion (STED) fluorescence lifetime imaging is demonstrated by using time-correlated single-photon counting (TCSPC) detection. The spatial resolution of the developed STED instrument was measured by imaging monodispersed 40-nm fluorescent beads and then determining their fwhm, and was 36 ± 9 and 40 ± 10 nm in the X and Y coordinates, respectively. The same beads measured by confocal microscopy were 450 ± 50 and 430 ± 30 nm, which is larger than the diffraction limit of light due to underfilling the microscope objective. Underfilling the objective and time gating the signal were necessary to achieve the stated STED spatial resolution. The same fluorescence lifetime (2.0 ± 0.1 ns) was measured for the fluorescent beads by using confocal or STED lifetime imaging. The instrument has been applied to study Alexa Fluor 594-phalloidin labeled F-actin-rich projections with dimensions smaller than the diffraction limit of light in cultured cells. Fluorescence lifetimes of the actin-rich projections range from 2.2 to 2.9 ns as measured by STED lifetime imaging.

Lesoine, Michael; Bose, Sayantan; Petrich, Jacob; Smith, Emily

2012-06-13T23:59:59.000Z

250

Nanometric Optical Imaging Frontiers in Chemical Imaging  

E-Print Network [OSTI]

Nanometric Optical Imaging Frontiers in Chemical Imaging Seminar Series Presented by... Professor growing field which has provided for nanometric optical imaging in the near-field. Even though a variety of techniques are being developed with nanometric optical imaging potential, near-field optics remains the most

251

E-Print Network 3.0 - advanced wind-tunnel instrumentation Sample...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

wind-tunnel instrumentation Search Powered by Explorit Topic List Advanced Search Sample search results for: advanced wind-tunnel instrumentation Page: << < 1 2 3 4 5 > >> 1...

252

E-Print Network 3.0 - advanced instrumentation information Sample...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

instrumentation information Search Powered by Explorit Topic List Advanced Search Sample search results for: advanced instrumentation information Page: << < 1 2 3 4 5 > >> 1 2nd...

253

E-Print Network 3.0 - advanced instrumented center Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

34 Major Research Instrumentation Program (MRI-R) Recovery and Reinvestment Summary: report on "Advanced Research Instrumentation and Facilities" (ARIF) was that the NSF should...

254

ECE 331 -Biomedical Instrumentation Department of Electrical & Computer Engineering, UBC Statistics & Safety  

E-Print Network [OSTI]

ECE 331 - Biomedical Instrumentation Department of Electrical & Computer Engineering, UBC Lab #1(n) [modulating generating] sensor. #12;ECE 331 - Biomedical Instrumentation Department of Electrical & Computer

Pulfrey, David L.

255

ECE 331 -Biomedical Instrumentation Department of Electrical & Computer Engineering, UBC Limb Plethysmography & Flow  

E-Print Network [OSTI]

ECE 331 - Biomedical Instrumentation Department of Electrical & Computer Engineering, UBC Lab #2 scale and flow (in L/ min). Compute linearity. #12;ECE 331 - Biomedical Instrumentation Department

Pulfrey, David L.

256

ECE 331 -Biomedical Instrumentation Department of Electrical & Computer Engineering, UBC Implant Design & Total Hip Arthroplasty  

E-Print Network [OSTI]

ECE 331 - Biomedical Instrumentation Department of Electrical & Computer Engineering, UBC Lab #6 screw from the implant once it is successfully implanted. #12;ECE 331 - Biomedical Instrumentation

Pulfrey, David L.

257

Integrated head package for top mounted nuclear instrumentation  

DOE Patents [OSTI]

A nuclear reactor such as a pressurized water reactor has an integrated head package providing structural support and increasing shielding leading toward the vessel head. A reactor vessel head engages the reactor vessel, and a control rod guide mechanism over the vessel head raises and lowers control rods in certain of the thimble tubes, traversing penetrations in the reactor vessel head, and being coupled to the control rods. An instrumentation tube structure includes instrumentation tubes with sensors movable into certain thimble tubes disposed in the fuel assemblies. Couplings for the sensors also traverse penetrations in the reactor vessel head. A shroud is attached over the reactor vessel head and encloses the control rod guide mechanism and at least a portion of the instrumentation tubes when retracted. The shroud forms a structural element of sufficient strength to support the vessel head, the control rod guide mechanism and the instrumentation tube structure, and includes radiation shielding material for limiting passage of radiation from retracted instrumentation tubes. The shroud is thicker at the bottom adjacent the vessel head, where the more irradiated lower ends of retracted sensors reside. The vessel head, shroud and contents thus can be removed from the reactor as a unit and rested safely and securely on a support.

Malandra, Louis J. (McKeesport, PA); Hornak, Leonard P. (Forest Hills, PA); Meuschke, Robert E. (Monroeville, PA)

1993-01-01T23:59:59.000Z

258

Nuclear and fundamental physics instrumentation for the ANS project  

SciTech Connect (OSTI)

This report summarizes work carried out during the period 1991-1995 in connection with the refinement of the concepts and detailed designs for nuclear and fundamental physics research instrumentation at the proposed Advanced Neutron source at Oak Ridge National Laboratory. Initially, emphasis was placed on refining the existing System Design Document (SDD-43) to detail more accurately the needs and interfaces of the instruments that are identified in the document. The conceptual designs of these instruments were also refined to reflect current thinking in the field of nuclear and fundamental physics. In particular, the on-line isotope separator (ISOL) facility design was reconsidered in the light of the development of interest in radioactive ion beams within the nuclear physics community. The second stage of this work was to define those instrument parameters that would interface directly with the reactor systems so that these parameters could be considered for the ISOL facility and particularly for its associated ion source. Since two of these options involved ion sources internal to the long slant beam tube, these were studied in detail. In addition, preliminary work was done to identify the needs for the target holder and changing facility to be located in the tangential through-tube. Because many of the planned nuclear and fundamental physics instruments have similar needs in terms of detection apparatus, some progress was also made in defining the parameters for these detectors. 21 refs., 32 figs., 2 tabs.

Robinson, S.J. [Tennessee Technological Univ., Cookeville, TN (United States). Dept. of Physics; Raman, S.; Arterburn, J.; McManamy, T.; Peretz, F.J. [Oak Ridge National Lab., TN (United States); Faust, H. [Institut Laue-Langevin, 38 - Grenoble (France); Piotrowski, A.E. [Soltan Inst. for Nuclear Studies, Otwock-Swierk (Poland)

1996-05-01T23:59:59.000Z

259

SIMS instrumentation and methodology for mapping of co-localized molecules  

SciTech Connect (OSTI)

We describe an innovative mode for localizing surface molecules. In this methodology, individual C{sub 60} impacts at 50 keV are localized using an electron emission microscope, EEM, synchronized with a time-of-flight mass spectrometer for the detection of the concurrently emitted secondary ions. The instrumentation and methodologies for generating ion maps are presented. The performance of the localization scheme depends on the characteristics of the electron emission, those of the EEM and of the software solutions for image analysis. Using 50 keV C{sub 60} projectiles, analyte specific maps and maps of co-emitted species have been obtained. The individual impact sites were localized within 1-2 ?m. A distinctive feature of recording individual impacts is the ability to identify co-emitted ions which originate from molecules co-located within ?10 nm.

Eller, M. J.; Verkhoturov, S. V.; Schweikert, E. A. [Department of Chemistry, Texas A and M University, College Station, Texas 77843-3144 (United States)] [Department of Chemistry, Texas A and M University, College Station, Texas 77843-3144 (United States); Della-Negra, S. [Institut de Physique Nucléaire d’Orsay, Université Paris-Sud 11, CNRS/IN2P3, F-91406 Orsay (France)] [Institut de Physique Nucléaire d’Orsay, Université Paris-Sud 11, CNRS/IN2P3, F-91406 Orsay (France)

2013-10-15T23:59:59.000Z

260

DAS: a data management system for instrument tests and operations  

E-Print Network [OSTI]

The Data Access System (DAS) is a metadata and data management software system, providing a reusable solution for the storage of data acquired both from telescopes and auxiliary data sources during the instrument development phases and operations. It is part of the Customizable Instrument WorkStation system (CIWS-FW), a framework for the storage, processing and quick-look at the data acquired from scientific instruments. The DAS provides a data access layer mainly targeted to software applications: quick-look displays, pre-processing pipelines and scientific workflows. It is logically organized in three main components: an intuitive and compact Data Definition Language (DAS DDL) in XML format, aimed for user-defined data types; an Application Programming Interface (DAS API), automatically adding classes and methods supporting the DDL data types, and providing an object-oriented query language; a data management component, which maps the metadata of the DDL data types in a relational Data Base Management Syste...

Frailis, Marco; Zacchei, Andrea; Lodi, Marcello; Cirami, Roberto; Pasian, Fabio; Trifoglio, Massimo; Bulgarelli, Andrea; Gianotti, Fulvio; Franceschi, Enrico; Nicastro, Luciano; Conforti, Vito; Zoli, Andrea; Smart, Ricky; Morbidelli, Roberto; Dadina, Mauro

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "imaging instrumentation radiobiology" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

ATR NATIONAL SCIENTIFIC USER FACILITY INSTRUMENTATION ENHANCEMENT EFFORTS  

SciTech Connect (OSTI)

A key component of the Advanced Test Reactor (ATR) National Scientific User Facility (NSUF) effort is to enhance instrumentation techniques available to users conducting irradiation tests in this unique facility. In particular, development of sensors capable of providing ‘real-time’ measurements of key irradiation parameters is emphasized because of their potential to offer increased fidelity data and reduced post-test examination costs. This paper describes the strategy for identifying new instrumentation needed for ATR irradiations and the program underway to develop and evaluate new sensors to address these needs. Accomplishments from this program are illustrated by describing several new sensors now available to users of the ATR NSUF. In addition, progress is reported on current research efforts to provide users improved in-pile instrumentation.

Joy L. Rempe; Mitchell K. Meyer

2009-04-01T23:59:59.000Z

262

Safeguards instrumentation: a computer-based catalog. Second edition  

SciTech Connect (OSTI)

This catalog contains entries on new developments and on items listed in BNL 51450, which have either been carried over unchanged or been updated. More than 70 entries were deleted because of either obsolescence, insufficient interest in terms of safeguards, or lack of documentable development activities in recent years. Some old listings as well as new material was consolidated into more generic entries. As in the earlier document, the emphasis is on devices and instruments that are either in field use at this time or under active development. A few items such as NDA reference materials, instrument vans and certain shipping containers are included because they are important adjuncts to optimum utilization of safeguards instrumentation. This catalog does not include devices for physical protection. As was the case with its predecessor, most of the material in this catalog originated in the US and Canada; a few contributions came from member states of the European Community.

Auerbach, C.

1985-04-01T23:59:59.000Z

263

Characterisation of pulsed Carbon fiber illuminators for FIR instrument calibration  

E-Print Network [OSTI]

We manufactured pulsed illuminators emitting in the far infrared for the Planck-HFI bolometric instrument ground calibrations. Specific measurements have been conducted on these light sources, based on Carbon fibers, to understand and predict their properties. We present a modelisation of the temperature dependence of the thermal conductivity and the calorific capacitance of the fibers. A comparison between simulations and bolometer data is given, that shows the coherence of our model. Their small time constants, their stability and their emission spectrum pointing in the submm range make these illuminators a very usefull tool for calibrating FIR instruments.

S. Henrot-Versille; R. Cizeron; F. Couchot

2007-07-31T23:59:59.000Z

264

Characterisation of pulsed Carbon fiber illuminators for FIR instrument calibration  

E-Print Network [OSTI]

We manufactured pulsed illuminators emitting in the far infrared for the Planck-HFI bolometric instrument ground calibrations. Specific measurements have been conducted on these light sources, based on Carbon fibers, to understand and predict their properties. We present a modelisation of the temperature dependence of the thermal conductivity and the calorific capacitance of the fibers. A comparison between simulations and bolometer data is given, that shows the coherence of our model. Their small time constants, their stability and their emission spectrum pointing in the submm range make these illuminators a very usefull tool for calibrating FIR instruments.

Henrot-Versillé, S; Couchot, F

2007-01-01T23:59:59.000Z

265

Split image optical display  

DOE Patents [OSTI]

A video image is displayed from an optical panel by splitting the image into a plurality of image components, and then projecting the image components through corresponding portions of the panel to collectively form the image. Depth of the display is correspondingly reduced.

Veligdan, James T. (Manorville, NY)

2007-05-29T23:59:59.000Z

266

Effects of resonator losses on the sound production by clarinet-like instruments  

E-Print Network [OSTI]

for the prediction of the oscillation regimes is classical for musical instruments producing self-sustained

Boyer, Edmond

267

Efficiency, accuracy, and stability issues in discrete-time simulations of single reed wind instruments  

E-Print Network [OSTI]

the basic nonlinear mechanisms that generate self-sustained oscillations in a single reed instrument. Due

Avanzini, Federico

268

Experiment #1 Maintenance of UV/vis Instruments  

E-Print Network [OSTI]

considerably worse than it should be. For these reasons, most companies have a preventive maintenance program that might be included in a preventive maintenance program for a UV-visible spectrometer. Your taskExperiment #1 Maintenance of UV/vis Instruments Objectives: 1. Learn how to use different UV

Nazarenko, Alexander

269

Managing the Management: CORBAbased Instrumentation of Management Systems  

E-Print Network [OSTI]

Managing the Management: CORBA­based Instrumentation of Management Systems A. Keller Munich Network to dynamically exchange customer­ and technology­related data. In this context, management systems are crucial providers: On the one hand, different service providers have chosen different management systems

270

Offshore wind profile measurements from remote sensing instruments  

E-Print Network [OSTI]

Offshore wind profile measurements from remote sensing instruments Ioannis Antoniou (1) , Hans E) have been mounted on top of a transformer platform situated offshore close to the Nysted wind farm be used to supplement met mast measurements for offshore applications. #12;1. Introduction Exploiting

271

An Ice Lithography Instrument Anpan Han 1, John Chervinsky2  

E-Print Network [OSTI]

Page 1 An Ice Lithography Instrument Anpan Han 1, John Chervinsky2 , Daniel Branton3 , and J. A a new nano-patterning method called ice lithography, where ice is used as the resist. Water vapor. The vapor condenses, covering the sample with an amorphous layer of ice. To form a lift-off mask, ice

272

The instrumented dynamic perforation test applied to a composite shell  

E-Print Network [OSTI]

The instrumented dynamic perforation test applied to a composite shell S. Pattofatto, H. Tsitsiris Wilson, F-94230 Cachan, France Abstract. Perforation tests are commonly used on composites but give limited results. In this study, a single layer of a thermoplastic woven composite is tested at high

Paris-Sud XI, Université de

273

Priming Creativity Through Improvisation on an Adaptive Musical Instrument  

E-Print Network [OSTI]

at many levels of the workforce. Engineers are expected to find creative solutions to challenging problemsPriming Creativity Through Improvisation on an Adaptive Musical Instrument Garth Griffin Tufts Avenue, Medford, MA 02155 jacob@cs.tufts.edu ABSTRACT Creativity is a crucial skill in today's knowledge

Jacob, Robert J.K.

274

Towards Energy-Efficient Reactive Thermal Management in Instrumented Datacenters  

E-Print Network [OSTI]

Towards Energy-Efficient Reactive Thermal Management in Instrumented Datacenters Ivan Rodero, Eun techniques used to alleviate thermal anomalies (i.e., hotspots) in cloud datacenter's servers of by reducing such as voltage scaling that also can be applied to reduce the temperature of the servers in datacenters. Because

Pompili, Dario

275

MIT Department of Nuclear Engineering 1 Digital Instrumentation and Control  

E-Print Network [OSTI]

1 MIT Department of Nuclear Engineering 1 Digital Instrumentation and Control Issues in Nuclear Engineering 2 Nuclear Power Plant #12;2 MIT Department of Nuclear Engineering 3 Major Protection Functions Engineering 4 Background · Analog electro-mechanical systems in existing nuclear power plants are aging

Schweik, Charles M.

276

Instrumental Variables and the Search for Identification: From Supply and  

E-Print Network [OSTI]

and demand for flaxseed, the source of linseed oil.2 Wright noted the difficulty of obtaining estimatesInstrumental Variables and the Search for Identification: From Supply and Demand to Natural variables involved attempts to estimate demand and supply curves.1 Economists such as P.G. Wright, Henry

Ahmad, Sajjad

277

Femtosecond Transient Imaging  

E-Print Network [OSTI]

This thesis proposes a novel framework called transient imaging for image formation and scene understanding through impulse illumination and time images. Using time-of-flight cameras and multi-path analysis of global light ...

Kirmani, Ahmed (Ghulam Ahmed)

2010-01-01T23:59:59.000Z

278

Near-infrared fluorescence enhanced optical imaging: an analysis of penetration depth  

E-Print Network [OSTI]

, . . . . . . . 59 . . . . . . . 59 . . . . . . . 60 . . . . . . . 6 I vn Page 3. 2 ICCD system (instrumentation) . . 3. 2. 1 Laser diode and optical filters. . 3. 2. 2 Gain-modulated image intensifier and lenses. . . . . . . . . 3. 2. 3 CCD camera. . 3. 2.... 4 Modulation instrumentation. 3. 3 ICCD system (raw data acquisition and processing). . . . . 3. 3. 1 Data acquisition . . 3. 4 Data acquisition for filter combinations 63 65 . . . 66 67 67 . . . 70 71 74 4. DEVELOPMENT OF THEORETICAL...

Houston, Jessica Perea

2002-01-01T23:59:59.000Z

279

For more information please visit the programme website: http://www.ictp.it/programmes/mmp.aspx MASTER'S OF ADVANCED STUDIES IN MEDICAL PHYSICS  

E-Print Network [OSTI]

- Radiobiology - Radiation Physics - Radiation Dosimetry - Physics of Nuclear Medicine - Medical Physics Imaging in radiotherapy, diagnostic and interventional radiology, nuclear medicine and radiation protection in a hospital

280

OFFICE OF MATERIALS & LOGISTICS MANAGEMENT Policy for Charge Capture of Implant(s), Instrument(s), Device(s)  

E-Print Network [OSTI]

OFFICE OF MATERIALS & LOGISTICS MANAGEMENT Policy for Charge Capture of Implant(s), Instrument entirety and fax to Materials Management at x1993. 3.0 Materials Management must complete Section 2 Service. Materials Management will provide the product part number, cost and charge code, if applicable

Oliver, Douglas L.

Note: This page contains sample records for the topic "imaging instrumentation radiobiology" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

A thermal neutron source imager using coded apertures  

SciTech Connect (OSTI)

To facilitate the process of re-entry vehicle on-site inspections, it would be useful to have an imaging technique which would allow the counting of deployed multiple nuclear warheads without significant disassembly of a missile`s structure. Since neutrons cannot easily be shielded without massive amounts of materials, they offer a means of imaging the separate sources inside a sealed vehicle. Thermal neutrons carry no detailed spectral information, so their detection should not be as intrusive as gamma ray imaging. A prototype device for imaging at close range with thermal neutrons has been constructed using an array of {sup 3}He position-sensitive gas proportional counters combined with a uniformly redundant coded aperture array. A sealed {sup 252}Cf source surrounded by a polyethylene moderator is used as a test source. By means of slit and pinhole experiments, count rates of image-forming neutrons (those which cast a shadow of a Cd aperture on the detector) are compared with the count rates for background neutrons. The resulting ratio, which limits the available image contrast, is measured as a function of distance from the source. The envelope of performance of the instrument is defined by the contrast ratio, the angular resolution, and the total count rate as a function of distance from the source. These factors will determine whether such an instrument could be practical as a tool for treaty verification.

Vanier, P.E.; Forman, L.; Selcow, E.C.

1995-08-01T23:59:59.000Z

282

Imaging Sciences Workshop Proceedings  

SciTech Connect (OSTI)

This report contains the proceedings of the Imaging Sciences Workshop sponsored by C.A.S.LS., the Center for Advanced Signal & Image Sciences. The Center, established primarily to provide a forum where researchers can freely exchange ideas on the signal and image sciences in a comfortable intellectual environment, has grown over the last two years with the opening of a Reference Library (located in Building 272). The Technical Program for the 1996 Workshop include a variety of efforts in the Imaging Sciences including applications in the Microwave Imaging, highlighted by the Micro-Impulse Radar (MIR) system invented at LLNL, as well as other applications in this area. Special sessions organized by various individuals in Speech, Acoustic Ocean Imaging, Radar Ocean Imaging, Ultrasonic Imaging, and Optical Imaging discuss various applica- tions of real world problems. For the more theoretical, sessions on Imaging Algorithms and Computed Tomography were organized as well as for the more pragmatic featuring a session on Imaging Systems.

Candy, J.V.

1996-11-21T23:59:59.000Z

283

NMR imaging of materials  

SciTech Connect (OSTI)

Interest in the area of NMR imaging has been driven by the widespread success of medical imaging. John M. Listerud of the Pendergrass Diagnostic Research Laboratories, Steven W. Sinton of Lockheed, and Gary P. Drobny of the University of Washington describe the principal image reconstruction methods, factors limiting spatial resolution, and applications of imaging to the study of materials.

Listerud, J.M.; Sinton, S.W.; Drobny, G.P.

1989-01-01T23:59:59.000Z

284

A high-resolution imaging x-ray crystal spectrometer for high energy density plasmas  

SciTech Connect (OSTI)

Adapting a concept developed for magnetic confinement fusion experiments, an imaging crystal spectrometer has been designed and tested for HED plasmas. The instrument uses a spherically bent quartz [211] crystal with radius of curvature of 490.8 mm. The instrument was tested at the Titan laser at Lawrence Livermore National Laboratory by irradiating titanium slabs with laser intensities of 10{sup 19}–10{sup 20} W/cm{sup 2}. He-like and Li-like Ti lines were recorded, from which the spectrometer performance was evaluated. This spectrometer provides very high spectral resolving power (E/dE > 7000) while acquiring a one-dimensional image of the source.

Chen, Hui, E-mail: chen33@llnl.gov, E-mail: bitter@pppl.gov; Magee, E.; Nagel, S. R.; Park, J.; Schneider, M. B.; Stone, G.; Williams, G. J.; Beiersdorfer, P. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550-9234 (United States); Bitter, M., E-mail: chen33@llnl.gov, E-mail: bitter@pppl.gov; Hill, K. W. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States); Kerr, S. [Department of Applied Science, University of Alberta, Edmonton, Alberta T6G 2R3 (Canada)

2014-11-15T23:59:59.000Z

285

Instrumentation requirements from the user's view. [For airbreathing hypersonic engines  

SciTech Connect (OSTI)

The use of combustor diagnostics is considered from the point of view of demonstration of performance of an airbreathing hypersonic engine. The basic need is seen to be that of providing the data necessary to verify performance predictions for the engine as installed in the airplane. This necessitates the use of a diagnostics capability that can provide the inputs required by the computational analyses that will be used to assess this performance. Because of the cost of ground test facilities, a premium is placed on measurement technique reliability and redundancy of instrumentation. A mix of nonintrusive optical techniques and probe-based measurements is seen to be the best approach using current diagnostics capability; one such instrument mix is outlined for a ramjet/scramjet test program. 11 references.

Harsha, P.T.

1988-01-01T23:59:59.000Z

286

The neutron instrument Monte Carlo library MCLIB: Recent developments  

SciTech Connect (OSTI)

A brief review is given of the developments since the ICANS-XIII meeting made in the neutron instrument design codes using the Monte Carlo library MCLIB. Much of the effort has been to assure that the library and the executing code MC{_}RUN connect efficiently with the World Wide Web application MC-WEB as part of the Los Alamos Neutron Instrument Simulation Package (NISP). Since one of the most important features of MCLIB is its open structure and capability to incorporate any possible neutron transport or scattering algorithm, this document describes the current procedure that would be used by an outside user to add a feature to MCLIB. Details of the calling sequence of the core subroutine OPERATE are discussed, and questions of style are considered and additional guidelines given. Suggestions for standardization are solicited, as well as code for new algorithms.

Seeger, P.A.; Daemen, L.L.; Hjelm, R.P. Jr.; Thelliez, T.G.

1998-12-31T23:59:59.000Z

287

Seismic Imaging and Monitoring  

SciTech Connect (OSTI)

I give an overview of LANL's capability in seismic imaging and monitoring. I present some seismic imaging and monitoring results, including imaging of complex structures, subsalt imaging of Gulf of Mexico, fault/fracture zone imaging for geothermal exploration at the Jemez pueblo, time-lapse imaging of a walkway vertical seismic profiling data for monitoring CO{sub 2} inject at SACROC, and microseismic event locations for monitoring CO{sub 2} injection at Aneth. These examples demonstrate LANL's high-resolution and high-fidelity seismic imaging and monitoring capabilities.

Huang, Lianjie [Los Alamos National Laboratory

2012-07-09T23:59:59.000Z

288

DOE Handbook: Guide to good practices evaluation instrument examples  

SciTech Connect (OSTI)

Training evaluation determines a training program`s effectiveness in meeting its intended purpose: producing competent employees. Evaluation is the quality assurance component of a systematic approach to training program. This guide provides information on evaluation instruments used to gather employee, supervisor, and instructor feedback to identify strengths and weaknesses of training programs at DOE facilities. It should be used in conjunction with ``DOE Training Program Handbook: A Systematic Approach to Training`` and ``DOE Handbook, Alternative Systematic Approaches to Training.``

NONE

1997-01-01T23:59:59.000Z

289

The development of an effective portfolio assessment instrument  

E-Print Network [OSTI]

OF SCIENCE August 1993 Major Subject: Curriculum and Instruction THE DEVELOPMENT OF AN EFFECTIVE PORTFOLIO ASSESSMENT INSTRUMENT A Thesis by KAREN LEIGH ALDERETE Approved as to style and content by: Viola E. Florez ( Chair of Committee ) Rafael ra... (Schroeder and Hunsburger, 1989). A good writing curriculum for students at-risk should include several components. There must be an emphasis on meaningful conununication. Less emphasis should be placed on learning mechanics of the language (e. g...

Alderete, Karen Leigh

1993-01-01T23:59:59.000Z

290

Instrumenting Buildings to Determine Retrofit Savings: Murphy's Law Revisited  

E-Print Network [OSTI]

the whole building electric load, building thermal loads and selected submetered loads. The emphasis of the lessons learned is on the instrumentation used and installation problems encountered during this project. INTRODUCTION During the past three and one..." should be able to avoid them. However, even experienced installers of building energy metering systems seem to struggle with some of these "obvious" problems and if a solution is developed, often there is no written record left for future reference...

Boecker, C. L.; Bohmer, C.; O'Neal, D. L.; Bryant, J.

291

Post-implementation review of inadequate core cooling instrumentation  

SciTech Connect (OSTI)

Studies of Three Mile Island (TMI) accident identified the need for additional instrumentation to detect inadequate core cooling (ICC) in nuclear power plants. Industry studies by plant owners and reactor vendors supported the conclusion that improvements were needed to help operators diagnose the approach to or existence of ICC and to provide more complete information for operator control of safety injection, flow to minimize the consequences of such an accident. In 1980, the US Nuclear Regulatory Commission (NRC) required further studies by the industry and described ICC instrumentation design requirements that included human factors and environmental considerations. On December 10, 1982, NRC issued to Babcock and Wilcox (BandW) licensees' orders for Modification of License and transmitted to all pressurized water reactor (PWR) licensees Generic Letter 82-28 to inform them of the revised NRC requirements. The instrumentation requirements for detection of ICC include upgraded subcooling margin monitors (SMMs), upgraded core exit thermocouples (CETs), and installation of a reactor coolant inventory tracking system (RCITS).

Anderson, J.L.; Anderson, R.L.; Hagen, E.W.; Morelock, T.C.; Huang, T.L.; Phillips, L.E.

1988-01-01T23:59:59.000Z

292

Ultrasonic wave-based structural health monitoring embedded instrument  

SciTech Connect (OSTI)

Piezoelectric sensors and actuators are the bridge between electronic and mechanical systems in structures. This type of sensor is a key element in the integrity monitoring of aeronautic structures, bridges, pressure vessels, wind turbine blades, and gas pipelines. In this paper, an all-in-one system for Structural Health Monitoring (SHM) based on ultrasonic waves is presented, called Phased Array Monitoring for Enhanced Life Assessment. This integrated instrument is able to generate excitation signals that are sent through piezoelectric actuators, acquire the received signals in the piezoelectric sensors, and carry out signal processing to check the health of structures. To accomplish this task, the instrument uses a piezoelectric phased-array transducer that performs the actuation and sensing of the signals. The flexibility and strength of the instrument allow the user to develop and implement a substantial part of the SHM technique using Lamb waves. The entire system is controlled using configuration software and has been validated through functional, electrical loading, mechanical loading, and thermal loading resistance tests.

Aranguren, G.; Monje, P. M., E-mail: pedromaria.monje@ehu.es [Electronic Design Group, Faculty of Engineering of Bilbao, University of the Basque Country, Bilbao (Spain); Cokonaj, Valerijan [AERnnova Engineering Solutions Ibérica S.A., Madrid (Spain)] [AERnnova Engineering Solutions Ibérica S.A., Madrid (Spain); Barrera, Eduardo; Ruiz, Mariano [Instrumentation and Applied Acoustic Research Group of the Technical University of Madrid, Madrid (Spain)] [Instrumentation and Applied Acoustic Research Group of the Technical University of Madrid, Madrid (Spain)

2013-12-15T23:59:59.000Z

293

Development of metrology instruments for grazing incidence mirrors  

SciTech Connect (OSTI)

The effective utilization of synchrotron radiation (SR) from high-brightness sources requires the use of optical components with very smooth surfaces and extremely precise shapes. Most manufacturers are not capable of measuring the figure and finish quality of the aspheric optics required for use in grazing incidence beam lines. Over the past several years we have developed measurement techniques and metrology instrumentation that have allowed us to measure the surface profile and roughness of large cylinder optics, up to one meter in length. Based on our measurements and feedback, manufacturers have been able to advance the state-of-the-art in mirror fabrication and are now able to produce acceptable components. Our analysis techniques enable designers to write meaningful specifications and predict the performance of real surfaces in their particular beamline configurations. Commercial instruments are now available for measuring surface microroughness with spatial periods smaller than about one millimeter. No commercial instruments are available for measuring the surface figure on cylindrical aspheres over long spatial periods, from one millimeter up to one meter. For that reason we developed a Long Trace Profiler (LTP) that measures surface profile over the long period range in a non-contact manner to extremely high accuracy. Examples of measured surfaces and data analysis techniques will be discussed, and limitations on the quality of optical surfaces related to intrinsic material properties will also be discussed. 15 refs., 14 figs., 2 tabs.

Takacs, P.Z. (Brookhaven National Lab., Upton, NY (USA)); Church, E.L. (Army Research and Development Command, Dover, NJ (USA)); Qian, Shi-nan (China Univ. of Science and Technology, Hefei, AH (China). Hefei National Synchrotron Radiation Lab.); Liu, Wuming (Academia Sinica, Beijing, BJ (China). Inst. of High Energy Physics)

1989-10-01T23:59:59.000Z

294

The EUV Imaging Spectrometer for Hinode  

SciTech Connect (OSTI)

The EUV Imaging Spectrometer (EIS) on Hinode will observe solar corona and upper transition region emission lines in the wavelength ranges 170?-?210 Angstroms and 250?-?290 Angstroms . The line centroid positions and profile widths will allow plasma velocities and turbulent or non-thermal line broadenings to be measured. We will derive local plasma temperatures and densities from the line intensities. The spectra will allow accurate determination of differential emission measure and element abundances within a variety of corona and transition region structures. These powerful spectroscopic diagnostics will allow identification and characterization of magnetic reconnection and wave propagation processes in the upper solar atmosphere. We will also directly study the detailed evolution and heating of coronal loops. The EIS instrument incorporates a unique two element, normal incidence design. The optics are coated with optimized multilayer coatings. We have selected highly efficient, backside-illuminated, thinned CCDs. These design features result in an instrument that has significantly greater effective area than previous orbiting EUV spectrographs with typical active region 2?-?5 s exposure times in the brightest lines. EIS can scan a field of 6x8.5 arc?min with spatial and velocity scales of 1 arc?sec and 25 km?s-1 per pixel. The instrument design, its absolute calibration, and performance are described in detail in this paper. EIS will be used along with the Solar Optical Telescope (SOT) and the X-ray Telescope (XRT) for a wide range of studies of the solar atmosphere.

Culhane,J.; Harra, L.; James, A.; Al-Janabi, K.; Bradley, L.; Chaudry, R.; Rees, K.; Tandy, J.; Thomas, P.; et al

2007-01-01T23:59:59.000Z

295

Matter in Extreme Conditions Instrument - Conceptual Design Report  

SciTech Connect (OSTI)

The SLAC National Accelerator Laboratory (SLAC), in collaboration with Argonne National Laboratory (ANL), Lawrence Livermore National Laboratory (LLNL), and the University of California at Los Angeles (UCLA), is constructing a Free-Electron Laser (FEL) research facility. The FEL has already met its performance goals in the wavelength range 1.5 nm - 0.15 nm. This facility, the Linac Coherent Light Source (LCLS), utilizes the SLAC 2-Mile Linear Accelerator (linac) and will produce sub-picosecond pulses of short wavelength X-rays with very high peak brightness and almost complete transverse coherence. The final one-third of the SLAC linac is used as the source of electrons for the LCLS. The high energy electrons are transported across the SLAC Research Yard, into a tunnel which houses a long undulator. In passing through the undulator, the electrons are bunched by the force of their own synchrotron radiation and produce an intense, monochromatic, spatially coherent beam of X-rays. By varying the electron energy, the FEL X-ray wavelength is tunable from 1.5 nm to 0.15 nm. The LCLS includes two experimental halls as well as X-ray optics and infrastructure necessary to create a facility that can be developed for research in a variety of disciplines such as atomic physics, materials science, plasma physics and biosciences. This Conceptual Design Report, the authors believe, confirms the feasibility of designing and constructing an X-ray instrument in order to exploit the unique scientific capability of LCLS by creating extreme conditions and study the behavior of plasma under those controlled conditions. This instrument will address the Office of Science, Fusion Energy Sciences, mission objective related to study of Plasma and Warm Dense Matter as described in the report titled LCLS, the First Experiments, prepared by the LCLS Scientific Advisory Committee (SAC) in September 2000. The technical objective of the LCLS Matter in Extreme Conditions (MEC) Instrument project is to design, build, and install at the LCLS an X-ray instrument that will complement the initial instrument suite included in the LCLS construction and the LUSI Major Item of Equipment (MIE) Instruments. As the science programs advance and new technological challenges appear, instrumentation must be developed and ready to conquer these new opportunities. The MEC concept has been developed in close consultation with the scientific community through a series of workshops team meetings and focused reviews. In particular, the MEC instrument has been identified as meeting one of the most urgent needs of the scientific community based on the advice of the LCLS Scientific Advisory Committee (SAC) in response to an open call for letters of intent (LOI) from the breadth of the scientific community. The primary purpose of the MEC instrument is to create High Energy Density (HED) matter and measure its physical properties. There are three primary elements of the MEC instrument: (A) Optical laser drivers that will create HED states by irradiation in several ways and provide diagnostics capability; (B) The LCLS x-ray free electron laser, which will provide the unique capability to create, probe and selectively pump HED states; and, (C) A suite of diagnostic devices required to observe the evolution of the HED state. These elements when combined in the MEC instrument meet the 'Mission Need' as defined in CD-0. For the purposes of the description we separate the types of experiments to be performed into three categories: (1) High pressure: Here we are interested in the generation of high pressure using the optical lasers to irradiate a surface that ablates and drives a pressure wave into a sample, similar to a piston. The pressures that can be reached exceed 1 Mbar and the properties of interest are for example, the reflectivity, conductivity, opacity as well as the changes driven by the pressure wave on, e.g., condensed matter structure. These phenomena will be studied by means of diffraction measurements, measurements of the pressure wave characteristics, in situ probing by

Boyce, R.F.; Boyce, R.M.; Haller, G.; Hastings, J.B.; Hays, G.; Lee, H.J.; /SLAC; Lee, R.W.; /LLNL, Livermore; Nagler, B.; /Rutherford; Scharfenstein, M.; Marsh, D.; White, W.E.; /SLAC; ,

2009-12-09T23:59:59.000Z

296

A new compact, high sensitivity neutron imaging system  

SciTech Connect (OSTI)

We have developed a new small neutron imaging system (SNIS) diagnostic for the OMEGA laser facility. The SNIS uses a penumbral coded aperture and has been designed to record images from low yield (10{sup 9}-10{sup 10} neutrons) implosions such as those using deuterium as the fuel. This camera was tested at OMEGA in 2009 on a rugby hohlraum energetics experiment where it recorded an image at a yield of 1.4 Multiplication-Sign 10{sup 10}. The resolution of this image was 54 {mu}m and the camera was located only 4 meters from target chamber centre. We recently improved the instrument by adding a cooled CCD camera. The sensitivity of the new camera has been fully characterized using a linear accelerator and a {sup 60}Co {gamma}-ray source. The calibration showed that the signal-to-noise ratio could be improved by using raw binning detection.

Caillaud, T.; Landoas, O.; Briat, M.; Rosse, B.; Thfoin, I.; Philippe, F.; Casner, A.; Bourgade, J. L.; Disdier, L. [CEA, DAM, DIF,F-91297 Arpajon (France); Glebov, V. Yu.; Marshall, F. J.; Sangster, T. C. [Laboratory for Laser Energetics, University of Rochester, 250 East River Road, Rochester, New York 14623-1299 (United States); Park, H. S.; Robey, H. F.; Amendt, P. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

2012-10-15T23:59:59.000Z

297

Gamma-Ray Imaging with the Coded Mask IBIS Telescope  

E-Print Network [OSTI]

The IBIS telescope onboard INTEGRAL, the ESA gamma-ray space mission to be launched in 2002, is a soft gamma-ray (20 keV - 10 MeV) device based on a coded aperture imaging system. We describe here basic concepts of coded masks, the imaging system of the IBIS telescope, and the standard data analysis procedures to reconstruct sky images. This analysis includes, for both the low-energy detector layer (ISGRI) and the high energy layer (PICSIT), iterative procedures which decode recorded shadowgrams, search for and locate sources, clean for secondary lobes, and then rotate and compose sky images. These procedures will be implemented in the Quick Look and Standard Analysis of the INTEGRAL Science Data Center (ISDC) as IBIS Instrument Specific Software.

Goldwurm, A; Gros, A; Stephen, J; Foschini, L; Gianotti, F; Natalucci, L; De Cesare, G; Santo, M D

2000-01-01T23:59:59.000Z

298

An instrument for high-throughput measurements of fiber mechanical properties  

E-Print Network [OSTI]

In this thesis, an instrument is designed and constructed for the purpose of measuring the mechanical properties of single fibers. The instrument is intended to provide high throughput measurement of single fiber geometric ...

Kristofek, Grant William, 1980-

2005-01-01T23:59:59.000Z

299

Contribution of the Peripheral Nervous System to Instrumental Learning and Performance  

E-Print Network [OSTI]

Previous research has demonstrated that the spinal cord is capable of a simple form of instrumental learning. In this instrumental learning paradigm, rats typically receive a complete spinal transection at the second thoracic vertebra...

Hoy, Kevin

2012-10-19T23:59:59.000Z

300

Instrumentation for Monitoring around Marine Renewable Energy Converters: Workshop Final Report  

SciTech Connect (OSTI)

Report on workshop held in Seattle for DOE WWPTO on instrument needs for monitoring marine energy devices

Copping, Andrea E.; Polagye, Brian

2014-01-31T23:59:59.000Z

Note: This page contains sample records for the topic "imaging instrumentation radiobiology" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

OBIT DEVELOPMENT MEMO SERIES NO. 39 1 Differential Instrumental Polarization Calibration  

E-Print Network [OSTI]

to as instrumental polarization. A standard part of data calibration is to charac- terize and remove the spurious

Groppi, Christopher

302

Instrument Failures for the da Vinci Surgical System: a Food and Drug Administration MAUDE Database Study  

E-Print Network [OSTI]

reports. The majority of failures (285) were of the instrument's wrist or tool tip. Cautery problemsInstrument Failures for the da Vinci Surgical System: a Food and Drug Administration MAUDE Database Background Our goal was to analyze reported instances of the da Vinci robotic surgical system instrument

303

Joint Urban 2003: Study Overview And Instrument Locations  

SciTech Connect (OSTI)

Quality-assured meteorological and tracer data sets are vital for establishing confidence that indoor and outdoor dispersion models used to simulate dispersal of potential toxic agents in urban atmospheres are giving trustworthy results. The U.S. Department of Defense-Defense Threat Reduction Agency and the U.S. Department of Homeland Security joined together to conduct the Joint Urban 2003 atmospheric dispersion study to provide this critically-needed high-resolution dispersion data. This major urban study was conducted from June 28 through July 31, 2003, in Oklahoma City, Oklahoma, with the participation of over 150 scientists and engineers from over 20 U.S. and foreign institutions. The Joint Urban 2003 lead scientist was Jerry Allwine (Pacific Northwest National Laboratory) who oversaw study design, logistical arrangements and field operations with the help of Joe Shinn (Lawrence Livermore National Laboratory), Marty Leach (Lawrence Livermore National Laboratory), Ray Hosker (Atmospheric Turbulence and Diffusion Division), Leo Stockham (Northrop Grumman Information Technology) and Jim Bowers (Dugway Proving Grounds). This report gives a brief overview of the field campaign, describing the scientific objectives, the dates of the intensive observation periods, and the instruments deployed. The data from this field study is available to the scientific community through an on-line database that is managed by Dugway Proving Ground. This report will be included in the database to provide its users with some general information about the field study, and specific information about the instrument coordinates. Appendix A of this document provides the definitive record of the instrument locations during this field campaign, and Appendix B lists all the study principal investigators and participants.

Allwine, K Jerry; Flaherty, Julia E.

2006-08-16T23:59:59.000Z

304

Why the Accuracy of Analytical Instrumentation Affects Boiler Combustion Efficiency  

E-Print Network [OSTI]

carbon monoxide level. A testing firm can provide this instrumentation or it can be purchased. The size and type of combustor to be tested will usually dictate the buy or contract decision. Small to medium boilers will usually be the ones involved... fan's damper linkage, that is adjusted by the operator on a shift-by-shift basis, to a dedicated microcomputer that looks at the load, oxygen, carbon monoxide/ carbon dioxide and even the flue gas opacity. The selection of the type of trim...

McFadden, R. W.

1984-01-01T23:59:59.000Z

305

Tomorrow optical interferometry: astrophysical prospects and instrumental issues  

E-Print Network [OSTI]

Interferometry has brought many new constraints in optical astronomy in the recent years. A major leap in this field is the opening of large interferometric facilities like the Very Large Telescope Interferometer and the Keck Interferometer to the astronomical community. Planning for the future is both easy --most specialists know in which directions to develop interferometry-- and difficult because of the increasing complexity of the technique. I present a short status of interferometry today. Then I detail the possible astrophysical prospects. Finally I address some important instrumental issues that are decisive for the future of interferometry.

F. Malbet

2006-09-14T23:59:59.000Z

306

Instrumental Methods for Professional and Amateur Collaborations in Planetary Astronomy  

E-Print Network [OSTI]

Amateur contributions to professional publications have increased exponentially over the last decades in the field of Planetary Astronomy. Here we review the different domains of the field in which collaborations between professional and amateur astronomers are effective and regularly lead to scientific publications. We discuss the instruments, detectors, softwares and methodologies typically used by amateur astronomers to collect the scientific data in the different domains of interest. Amateur contributions to the monitoring of planets and interplanetary matter, characterization of asteroids and comets, as well as the determination of the physical properties of Kuiper Belt Objects and exoplanets are discussed.

Mousis, O; Beaulieu, J -P; Bouley, S; Carry, B; Colas, F; Klotz, A; Pellier, C; Petit, J -M; Rousselot, P; Dib, M Ali; Beisker, W; Birlan, M; Buil, C; Delsanti, A; Frappa, E; Hammel, H B; Levasseur-Regourd, A -C; Orton, G S; Sanchez-Lavega, A; Santerne, A; Tanga, P; Vaubaillon, J; Zanda, B; Baratoux, D; Boehm, T; Boudon, V; Bouquet, A; Buzzi, L; Dauvergne, J -L; Decock, A; Delcroix, M; Drossart, P; Esseiva, N; Fischer, G; Fletcher, L N; Foglia, S; Gomez-Forrellad, J M; Guarro-Flo, J; Herald, D; Kugel, F; Lebreton, J -P; Lecacheux, J; Leroy, A; Maquet, L; Masi, G; Maury, A; Meyer, F; Pérez-Hoyos, S; Rajpurohit, A S; Rinner, C; Rogers, J H; Roques, F; Schmude,, R W; Sicardy, B; Tregon, B; Vanhuysse, M; Wesley, A; Widemann, T

2013-01-01T23:59:59.000Z

307

Coherent electron cooling proof of principle instrumentation design  

SciTech Connect (OSTI)

The goal of the Coherent Electron Cooling Proof-of-Principle (CeC PoP) experiment being designed at RHIC is to demonstrate longitudinal (energy spread) cooling before the expected CD-2 for eRHIC. The scope of the experiment is to longitudinally cool a single bunch of 40 GeV/u gold ions in RHIC. This paper will describe the instrumentation systems proposed to meet the diagnostics challenges. These include measurements of beam intensity, emittance, energy spread, bunch length, position, orbit stability, and transverse and temporal alignment of electron and ion beams.

Gassner D. M.; Litvinenko, V.; Michnoff, R.; Miller, T.; Minty, M.; Pinayev, I.

2012-04-15T23:59:59.000Z

308

Virtual experiments: Combining realistic neutron scattering instrument and sample simulations  

SciTech Connect (OSTI)

A new sample component is presented for the Monte Carlo, ray-tracing program, McStas, which is widely used to simulate neutron scattering instruments. The new component allows the sample to be described by its material dynamic structure factor, which is separated into coherent and incoherent contributions. The effects of absorption and multiple scattering are treated and results from simulations and previous experiments are compared. The sample component can also be used to treat any scattering material which may be close to the sample and therefore contaminates the total, measured signal.

Farhi, E. [Institut Laue Langevin, BP 156, 38042 Grenoble Cedex 9 (France)], E-mail: farhi@ill.fr; Hugouvieux, V. [INRA, UR1268 Biopolymeres Interactions Assemblages, F-44300 Nantes (France); Johnson, M.R. [Institut Laue Langevin, BP 156, 38042 Grenoble Cedex 9 (France); Kob, W. [Laboratoire des Colloides, Verres et Nanomateriaux, Universite Montpellier II, place E. Bataillon, 34095 Montpellier Cedex 5 (France)

2009-08-01T23:59:59.000Z

309

Los Alamos instrument to shine light on Mars habitability  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsrucLas Conchas recovery challenge fund Las Conchas recoveryNuclear energyInstrument to shine

310

Los Alamos laser instrument arrives on Red Planet's surface  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsrucLas Conchas recovery challenge fund Las Conchas recoveryNuclear energyInstrument toLaser

311

Imaging in radiotherapy  

SciTech Connect (OSTI)

The text contains details of recording media, image quality, sensitometry, processing and equipment used in radiotherapy for imaging. It reflects part of the syllabus for the College of Radiographers.

Taylor, J.

1987-01-01T23:59:59.000Z

312

User Science Images  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Image: OBrianImageBig.png | png | 5 MB SlavaFull.png FES: Small Scale Experimental Plasma Research October 21, 2010 | Author(s): Vyacheslav Lukin (NRL) | Category: Fusion Energy |...

313

Dual Plane Imaging  

E-Print Network [OSTI]

We outline a technique called Dual Plane Imaging which should significantly improve images which would otherwise be blurred due to atmospheric turbulence. The technique involves capturing all the spatial, directional and temporal information about the arriving photons and processing the data afterwards to produce the sharpened images. The technique has particular relevance for imaging at around 400-1000nm on extremely large telescopes (ELTs).

Parry, Ian

2015-01-01T23:59:59.000Z

314

Consumers' Image of Broilers.  

E-Print Network [OSTI]

which they feel the product possesses. This research was designed to determine consumers' favorable and unfavorable images as to broilers, both in making purchases in stores and in serving them as a meat dish. These images, summarized briefly here... count. The Preparation and Cooking Image: The h0u.l wife's image of broilers focuses on one metliotl- frying. The major deterrent to preparing othci dishes was that these are either too difficult or canno* be prepared satisfactorily...

Courtenay, Henry V.; Branson, Robert E.

1962-01-01T23:59:59.000Z

315

Imaging with Scattered Neutrons  

E-Print Network [OSTI]

We describe a novel experimental technique for neutron imaging with scattered neutrons. These scattered neutrons are of interest for condensed matter physics, because they permit to reveal the local distribution of incoherent and coherent scattering within a sample. In contrast to standard attenuation based imaging, scattered neutron imaging distinguishes between the scattering cross section and the total attenuation cross section including absorption. First successful low-noise millimeter-resolution images by scattered neutron radiography and tomography are presented.

H. Ballhausen; H. Abele; R. Gaehler; M. Trapp; A. Van Overberghe

2006-10-30T23:59:59.000Z

316

Design and performance of a combined secondary ion mass spectrometry-scanning probe microscopy instrument for high sensitivity and high-resolution elemental three-dimensional analysis  

SciTech Connect (OSTI)

State-of-the-art secondary ion mass spectrometry (SIMS) instruments allow producing 3D chemical mappings with excellent sensitivity and spatial resolution. Several important artifacts however arise from the fact that SIMS 3D mapping does not take into account the surface topography of the sample. In order to correct these artifacts, we have integrated a specially developed scanning probe microscopy (SPM) system into a commercial Cameca NanoSIMS 50 instrument. This new SPM module, which was designed as a DN200CF flange-mounted bolt-on accessory, includes a new high-precision sample stage, a scanner with a range of 100 {mu}m in x and y direction, and a dedicated SPM head which can be operated in the atomic force microscopy (AFM) and Kelvin probe force microscopy modes. Topographical information gained from AFM measurements taken before, during, and after SIMS analysis as well as the SIMS data are automatically compiled into an accurate 3D reconstruction using the software program 'SARINA,' which was developed for this first combined SIMS-SPM instrument. The achievable lateral resolutions are 6 nm in the SPM mode and 45 nm in the SIMS mode. Elemental 3D images obtained with our integrated SIMS-SPM instrument on Al/Cu and polystyrene/poly(methyl methacrylate) samples demonstrate the advantages of the combined SIMS-SPM approach.

Wirtz, Tom; Fleming, Yves; Gerard, Mathieu [Department 'Science and Analysis of Materials' (SAM), Centre de Recherche Public, Gabriel Lippmann, 41 rue du Brill, L-4422 Belvaux (Luxembourg); Gysin, Urs; Glatzel, Thilo; Meyer, Ernst [Department of Physics, Universitaet Basel, Klingelbergstrasse 82, CH-4056 Basel (Switzerland); Wegmann, Urs [Department of Physics, Universitaet Basel, Klingelbergstrasse 82, CH-4056 Basel (Switzerland); Ferrovac GmbH, Thurgauerstr. 72, CH-8050 Zuerich (Switzerland); Maier, Urs [Ferrovac GmbH, Thurgauerstr. 72, CH-8050 Zuerich (Switzerland); Odriozola, Aitziber Herrero; Uehli, Daniel [SPECS Zurich GmbH, Technoparkstr. 1, CH-8005 Zuerich (Switzerland)

2012-06-15T23:59:59.000Z

317

Medical imaging systems  

DOE Patents [OSTI]

A medical imaging system provides simultaneous rendering of visible light and diagnostic or functional images. The system may be portable, and may include adapters for connecting various light sources and cameras in open surgical environments or laparascopic or endoscopic environments. A user interface provides control over the functionality of the integrated imaging system. In one embodiment, the system provides a tool for surgical pathology.

Frangioni, John V

2013-06-25T23:59:59.000Z

318

Magnetic Imaging Wolfgang Kuch  

E-Print Network [OSTI]

Magnetic Imaging Wolfgang Kuch Freie Universit¨at Berlin, Institut f¨ur Experimentalphysik, Arnimallee 14, 14195 Berlin, Germany kuch@physik.fu-berlin.de Abstract. Imaging of magnetic domains has- ern techniques is used nowadays routinely for magnetic imaging of magnetic ma- terials

Kuch, Wolfgang

319

Human Functional Brain Imaging  

E-Print Network [OSTI]

Human Functional Brain Imaging 1990­2009 September 2011 Portfolio Review Summary Brain Imaging #12 Dale ­ one of our first Trustees. Understanding the brain remains one of our key strategic aims today three-fold: · to identify the key landmarks and influences on the human functional brain imaging

Rambaut, Andrew

320

Human Functional Brain Imaging  

E-Print Network [OSTI]

Human Functional Brain Imaging 1990­2009 September 2011 Portfolio Review #12;2 | Portfolio Review: Human Functional Brain ImagingThe Wellcome Trust is a charity registered in England and Wales, no's role in supporting human functional brain imaging and have informed `our' speculations for the future

Rambaut, Andrew

Note: This page contains sample records for the topic "imaging instrumentation radiobiology" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Near-electrode imager  

DOE Patents [OSTI]

An apparatus, near-electrode imager, for employing nuclear magnetic resonance imaging to provide in situ measurements of electrochemical properties of a sample as a function of distance from a working electrode. The near-electrode imager uses the radio frequency field gradient within a cylindrical toroid cavity resonator to provide high-resolution nuclear magnetic resonance spectral information on electrolyte materials.

Rathke, Jerome W. (Lockport, IL); Klingler, Robert J. (Westmont, IL); Woelk, Klaus (Wachtberg, DE); Gerald, II, Rex E. (Brookfield, IL)

2000-01-01T23:59:59.000Z

322

The BEAR program NRL plasma physics instrumentation measurements  

SciTech Connect (OSTI)

The BEAR program was a joint effort to launch, and demonstrate the feasibility of operating, a 1 MeV 10 ma Neutral Particle Beam (NPB) accelerator from a space platform. The accelerator design and manufacture were the responsibility of Los Alamos National Lab (LANL); diagnostics associated with accelerator operation and beam-plasma effects were also to be undertaken by LANL and NRL. Payload Integration and Telemetry was provided by the Air Force Geophysical Lab (AFGL) and Northeastern University (NEU). Beam effects on the local plasma in addition to accelerator produced vehicle effects (e.g., charging) were the responsibility of NRL as outlined herein. The BEAR rocket was launched successfully during the early morning hours of July 13 from White Sands Missile Range, White Sands, N.M. The NRL contribution to this effort included three instrument packages designed to diagnose beam-plasma and vehicle-plasma interactions. The instruments included: (1) Langmuir probe (LP) design consisting of 4 separate sensors; (2) High voltage (HIV) Langmuir Probe designed to monitor vehicle charging through current polarity changes; and (3) Plasma Wave Receive (PWR) designed to characterize the plasma wave emissions covering a broad frequency range from near DC to 50 MHz.

Walker, D.N.; Baumback, M.M.; Haas, D.G.; Rodriguez, P.; Siefring, C.L.; Doggett, R.A. [Naval Research Lab., Washington, DC (United States)

1989-11-15T23:59:59.000Z

323

INSTRUMENTATION FOR SURVEYING ACOUSTIC SIGNALS IN NATURAL GAS TRANSMISSION LINES  

SciTech Connect (OSTI)

In the U.S. natural gas is distributed through more than one million miles of high-pressure transmission pipelines. If all leaks and infringements could be detected quickly, it would enhance safety and U.S. energy security. Only low frequency acoustic waves appear to be detectable over distances up to 60 km where pipeline shut-off valves provide access to the inside of the pipeline. This paper describes a Portable Acoustic Monitoring Package (PAMP) developed to record and identify acoustic signals characteristic of: leaks, pump noise, valve and flow metering noise, third party infringement, manual pipeline water and gas blow-off, etc. This PAMP consists of a stainless steel 1/2 inch NPT plumbing tree rated for use on 1000 psi pipelines. Its instrumentation is designed to measure acoustic waves over the entire frequency range from zero to 16,000 Hz by means of four instruments: (1) microphone, (2) 3-inch water full range differential pressure transducer with 0.1% of range sensitivity, (3) a novel 3 inch to 100 inch water range amplifier, using an accumulator with needle valve and (4) a line-pressure transducer. The weight of the PAMP complete with all accessories is 36 pounds. This includes a remote control battery/switch box assembly on a 25-foot extension chord, a laptop data acquisition computer on a field table and a sun shield.

John L. Loth; Gary J. Morris; George M. Palmer; Richard Guiler; Deepak Mehra

2003-09-01T23:59:59.000Z

324

Instrument for measurement of vacuum in sealed thin wall packets  

DOE Patents [OSTI]

An instrument is described for the measurement of vacuum within sealed packets, the packets having a wall sufficiently thin that it can be deformed by the application of an external vacuum to small area thereof. The instrument has a detector head for placement against the deformable wall of the packet to apply the vacuum in a controlled manner to accomplish a limited deformation or lift of the wall, with this deformation or lift monitored by the application of light as via a bifurcated light pipe. Retro-reflected light through the light pipe is monitored with a photo detector. An abrupt change (e.g., a decrease) of retro-reflected light signals the wall movement such that the value of the vacuum applied through the head to achieve this initiation of movement is equal to the vacuum within the packet. In a preferred embodiment a vacuum reference plate is placed beneath the packet to ensure that no deformation occurs on the reverse surface of the packet. A packet production line model is also described. 3 figures.

Kollie, T.G.; Thacker, L.H.; Fine, H.A.

1993-10-05T23:59:59.000Z

325

Enhanced In-pile Instrumentation for Material Testing Reactors  

SciTech Connect (OSTI)

An increasing number of U.S. nuclear research programs are requesting enhanced in-pile instrumentation capable of providing real-time measurements of key parameters during irradiations. For example, fuel research and development funded by the U.S. Department of Energy now emphasize approaches that rely on first principle models to develop optimized fuel designs that offer significant improvements over current fuels. To facilitate this approach, high fidelity, real-time data are essential for characterizing the performance of new fuels during irradiation testing. Furthermore, sensors that obtain such data must be miniature, reliable and able to withstand high flux/high temperature conditions. Depending on user requirements, sensors may need to obtain data in inert gas, pressurized water, or liquid metal environments. To address these user needs, in-pile instrumentation development efforts have been initiated as part of the Advanced Test Reactor (ATR) National Scientific User Facility (NSUF), the Fuel Cycle Research & Development (FCR&D), and the Nuclear Energy Enabling Technology (NEET) programs. This paper reports on recent INL achievements to support these programs. Specifically, an overview of the types of sensors currently available to support in-pile irradiations and those sensors currently available to MTR users are identified. In addition, recent results and products available from sensor research and development are detailed. Specifically, progress in deploying enhanced in-pile sensors for detecting elongation and thermal conductivity are reported. Results from research to evaluate the viability of ultrasonic and fiber optic technologies for irradiation testing are also summarized.

Joy Rempe; Darrell Knudson; Joshua Daw; Troy Unruh; Benjamin Chase; Kurt Davis; Robert Schley

2012-07-01T23:59:59.000Z

326

Advanced research in instrumentation and control technology: Acoustic parameter studies  

SciTech Connect (OSTI)

In the process of developing acoustic/ultrasonic instruments for coal conversion and combustion processes, there is a need to understand various complex relations between acoustic parameters and physical properties of coal/gas and coal/liquid media so that the instrument readings and measurement accuracy can be evaluated and new sensing techniques can be developed. The primary objective of this project is to examine the theory and perform measurements of acoustic/ultrasonic parameters in such coal media. The acoustic parameters of interest are sound speed, attenuation, scattering pattern, and resonance scattering, which relate directly or indirectly to coal concentration, particle size and distribution, and rheological and thermal properties. In summary, we have developed a laboratory technique for accurate attenuation measurement in highly viscous liquids and coal slurries. For pure liquids, the attenuation in low frequency (0.8 to 2 MHz) provides a direct measurement of fluid shear viscosity. For coal slurries of low concentration (<10% by weight) attenuation in the same frequency range still follows the variation of fluid viscosity. But, for slurries of higher coal concentration, anomalous attenuation may be measured, depending on the fluid structure, which is believed to be a micor-inhomogeneous medium. 8 refs., 5 figs., 1 tab.

Sheen, S.H.; Bobis, J.P.; Raptis, A.C.

1986-01-01T23:59:59.000Z

327

Radiological Instrumentation Assessment for King County Wastewater Treatment Division  

SciTech Connect (OSTI)

The King County Wastewater Treatment Division (WTD) have concern about the aftermath of a radiological dispersion event (RDE) leading to the introduction of significant quantities of radioactive material into its combined sanitary and storm sewer system. Radioactive material could come from the use of a radiological dispersion device (RDD). RDDs include "dirty bombs" that are not nuclear detonations but are explosives designed to spread radioactive material. Radioactive material also could come from deliberate introduction or dispersion of radioactive material into the environment, including waterways and water supply systems. Volume 2 of PNNL-15163 assesses the radiological instrumentation needs for detection of radiological or nuclear terrorism, in support of decisions to treat contaminated wastewater or to bypass the West Point Treatment Plant (WPTP), and in support of radiation protection of the workforce, the public, and the infrastructure of the WPTP. Fixed radiation detection instrumentation should be deployed in a defense-in-depth system that provides 1) early warning of significant radioactive material on the way to the WPTP, including identification of the radionuclide(s) and estimates of the soluble concentrations, with a floating detector located in the wet well at the Interbay Pump Station and telemetered via the internet to all authorized locations; 2) monitoring at strategic locations within the plant, including 2a) the pipe beyond the hydraulic ram in the bar screen room; 2b) above the collection funnels in the fine grit facility; 2c) in the sampling tank in the raw sewage pump room; and 2d) downstream of the concentration facilities that produce 6% blended and concentrated biosolids. Engineering challenges exist for these applications. It is necessary to deploy both ultra-sensitive detectors to provide early warning and identification and detectors capable of functioning in high-dose rate environments that are likely under some scenarios, capable of functioning from 10 microrems per hour (background) up to 1000 rems per hour. Software supporting fixed spectroscopic detectors is needed to provide prompt, reliable, and simple interpretations of spectroscopic outputs that are of use to operators and decision-makers. Software to provide scientists and homeland security personnel with sufficient technical detail for identification, quantification, waste management decisions, and for the inevitable forensic and attribution needs must be developed. Computational modeling using MCNP software has demonstrated that useful detection capabilities can be deployed. In particular, any of the isotopes examined can be detected at levels between 0.01 and 0.1 ?Ci per gallon. General purpose instruments that can be used to determine the nature and extent of radioactive contamination and measure radiation levels for purposes of protecting personnel and members of the public should be available. One or more portable radioisotope identifiers (RIIDs) should be available to WTD personnel. Small, portable battery-powered personal radiation monitors should be widely available WTD personnel. The personal monitors can be used for personal and group radiation protection decisions, and to alert management to the need to get expert backup. All considerations of radiological instrumentation require considerations of training and periodic retraining of personnel, as well as periodic calibration and maintenance of instruments. Routine “innocent” alarms will occur due to medical radionuclides that are legally discharged into sanitary sewers on a daily basis.

Strom, Daniel J.; McConn, Ronald J.; Brodzinski, Ronald L.

2005-05-19T23:59:59.000Z

328

Automation in image cytometry : continuous HCS and kinetic image cytometry  

E-Print Network [OSTI]

OF CALIFORNIA, SAN DIEGO Automation in Image Cytometry:xiv Abstract of Dissertation Automation in Image Cytometry:

Charlot, David J.

2012-01-01T23:59:59.000Z

329

Generating audio-responsive video images in real-time for a live symphony performance  

E-Print Network [OSTI]

instruments to cutting-edge video image productions for musical groups of all sizes. Throughout this evolution, a common goal has been to create real-time, audio-responsive visuals that accentuate the sound and enhance the performance. This paper explains...

Beane, Allison Brooke

2007-09-17T23:59:59.000Z

330

SUBMOLECULAR IMAGING OF EPITAXIALLY CRYSTALLIZED HELICAL POLYOLEFINS BY ATOMIC FORCE MICROSCOPY  

E-Print Network [OSTI]

Digital Instruments, Inc., Santa Barbara, Cal. USA. Images were taken with an A­type scan head (max. scan microscopy EM and electron diffraction ED. AFM pictures with high resolution could be obtained when using polypropylene has been determined by electron microscopy EM and electron diffraction ED: chain conformation

Peters, Achim

331

An infrared image of a dog, with warmest areas appearing the brightest.  

E-Print Network [OSTI]

industry and universities, we now have detector arrays capable of making infrared images, much as charge (refrigerant) to cool their telescopes. The cryogen is kept in a pressurized cryostat, which is similar-operating temperatures. Combined with small amounts of cryogen that refrigerate the instruments, these telescopes achieve

332

The Focusing Optics x-ray Solar Imager: FOXSI Sam Kruckera,b, Steven Christec, Lindsay Glesenera,d, Shin-nosuke Ishikawaa, Stephen  

E-Print Network [OSTI]

University, Furo-cho, Chikusa-ku, Nagoya 464-8601, Japan ABSTRACT The Focusing Optics x-ray Solar Imager. Today's leading solar HXR instrument, the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI, solar physics, solar flares, silicon strip detectors, grazing-incidence optics, high-energy x-ray optics

California at Berkeley, University of

333

Improving resolution and depth of astronomical observations via modern mathematical methods for image analysis  

E-Print Network [OSTI]

In the past years modern mathematical methods for image analysis have led to a revolution in many fields, from computer vision to scientific imaging. However, some recently developed image processing techniques successfully exploited by other sectors have been rarely, if ever, experimented on astronomical observations. We present here tests of two classes of variational image enhancement techniques: "structure-texture decomposition" and "super-resolution" showing that they are effective in improving the quality of observations. Structure-texture decomposition allows to recover faint sources previously hidden by the background noise, effectively increasing the depth of available observations. Super-resolution yields an higher-resolution and a better sampled image out of a set of low resolution frames, thus mitigating problematics in data analysis arising from the difference in resolution/sampling between different instruments, as in the case of EUCLID VIS and NIR imagers.

Castellano, Marco; Fontana, Adriano; Merlin, Emiliano; Pilo, Stefano; Falcone, Maurizio

2015-01-01T23:59:59.000Z

334

Optical instrumentation for on-line analysis of chemical processes  

SciTech Connect (OSTI)

Optical diagnostics provide the capability for nonintrusive, on-line, real time analysis of chemical process streams. Several laser-based methods for monitoring fossil energy processes have been evaluated. Among the instrumentation techniques which appear quite promising are coherent anti-Stokes Raman spectroscopy (CARS), laser-induced breakdown spectroscopy (LIBS), and synchronous detection of laser-induced fluorescence (SDLIF). A CARS diagnostic was implemented on a coal gasifier and was successfully employed to measure species concentrations and temperatures within the process stream. The LIBS approach has been used to identify total trace impurities (e.g., Na, K, and S) within a gasifier. Recently, individual components in mixtures of aromatics hydrocarbons have been resolved via the synchronous detection of laser-induced fluorescence. 9 figures.

Hartford, A. Jr.; Cremers, D.A.; Loree, T.R.; Quigley, G.P.

1983-01-01T23:59:59.000Z

335

Instrumentation and Equipment for Three Independent Research Labs  

SciTech Connect (OSTI)

Completed in 2011, Albright's new Science Center includes three independent student and faculty research labs in Biology, Chemistry/Biochemistry, and Physics (separate from teaching labs). Providing independent research facilities, they eliminate disruptions in classrooms and teaching labs, encourage and accommodate increased student interest, and stimulate advanced research. The DOE grant of $369,943 enabled Albright to equip these advanced labs for 21st century science research, with much instrumentation shared among departments. The specialty labs will enable Albright to expand its student-faculty research program to meet growing interest, help attract superior science students, maximize faculty expertise, and continue exceeding its already high rates of acceptance for students applying for postgraduate education or pharmaceutical research positions. Biology instrumentation/equipment supports coursework and independent and collaborative research by students and faculty. The digital shaker, CO{sub 2} and water bath incubators (for controlled cell growth), balance, and micropipettes support cellular biology research in the advanced cell biology course and student-faculty research into heavy metal induction of heat shock proteins in cultured mammalian cells and the development of PCR markers from different populations of the native tree, Franklinia. The gravity convection oven and lyophilizer support research into physical and chemical analysis of floodplain sediments used in assessment of riparian restoration efforts. The Bio-Rad thermocycler permits fast and accurate DNA amplification as part of research into genetic diversity in small mammal populations and how those populations are affected by land-use practices and environmental management. The Millipore water deionizing system and glassware washer provide general support of the independent research lab and ensure quality control of coursework and interdisciplinary research at the intersection of biology, chemistry, and toxicology. Grant purchases support faculty and students working in the areas of plant cellular biology, landscape ecology and wildlife management, wetland restoration, and ecotoxicology of aquatic invertebrates. Chemistry/BioChemistry instrumentation supports a wide range of research and teaching needs. The Dell quad core Xeon processors and Gaussian 09 support computational research efforts of two of our faculty. The computational work of one of these groups is part of close collaboration with one organic chemist and provides support info for the synthetic work of this professor and his students. Computational chemistry studies were also introduced into the physical chemistry laboratory course for junior chemistry concentrators. The AKTA plus system and superdex columns, Thermoscientific Sorvall RC-6 plus superspeed centrifuge, Nanodrop spectrometer, Eppendorf microfuge, Homogenizer and Pipetman pipetters were incorporated into a research project involving purification and characterization of a construct of beta 2-microglobulin by one of our biochemists. The vacuum system (glove box, stand, and pump) makes a significant contribution to the research of our inorganic chemist, the newest department member, working on research projects with four students. The glove box provides the means to carry out their synthetic work in an oxygenless atmosphere. Supporting basic research pursued by faculty and students, the remaining items (refrigerator/freezer units for flammable storage, freezer, refrigerated water bath, rotary evaporator system, vacuum oven, analytical and top-loading balances) were distributed between our biochemistry and chemistry research labs. The Nanodrop spectrometer, Sorvall centrifuge, and rotary evaporator system are used in several junior/senior lab courses in both biochemistry and chemistry. To date, 14 undergraduate research students have been involved in projects using the new instrumentation and equipment provided by this grant. Physics equipment acquired is radically transforming Albright research and teaching capabilities. The tw

Darlene Roth

2012-03-29T23:59:59.000Z

336

Archeops: an instrument for present and future cosmology  

E-Print Network [OSTI]

Archeops is a balloon-borne instrument dedicated to measure the cosmic microwave background (CMB) temperature anisotropies. It has, in the millimetre domain (from 143 to 545 GHz), a high angular resolution (about 10 arcminutes) in order to constrain high l multipoles, as well as a large sky coverage fraction (30%) in order to minimize the cosmic variance. It has linked, before WMAP, Cobe large angular scales to the first acoustic peak region. From its results, inflation motivated cosmologies are reinforced with a flat Universe (Omega_tot=1 within 3%). The dark energy density and the baryonic density are in very good agreement with other independent estimations based on supernovae measurements and big bang nucleosynthesis. Important results on galactic dust emission polarization and their implications for Planck are also addressed.

M. Tristram

2003-09-12T23:59:59.000Z

337

Image compression technique  

DOE Patents [OSTI]

An image is compressed by identifying edge pixels of the image; creating a filled edge array of pixels each of the pixels in the filled edge array which corresponds to an edge pixel having a value equal to the value of a pixel of the image array selected in response to the edge pixel, and each of the pixels in the filled edge array which does not correspond to an edge pixel having a value which is a weighted average of the values of surrounding pixels in the filled edge array which do correspond to edge pixels; and subtracting the filled edge array from the image array to create a difference array. The edge file and the difference array are then separately compressed and transmitted or stored. The original image is later reconstructed by creating a preliminary array in response to the received edge file, and adding the preliminary array to the received difference array. Filling is accomplished by solving Laplace`s equation using a multi-grid technique. Contour and difference file coding techniques also are described. The techniques can be used in a method for processing a plurality of images by selecting a respective compression approach for each image, compressing each of the images according to the compression approach selected, and transmitting each of the images as compressed, in correspondence with an indication of the approach selected for the image. 16 figs.

Fu, C.Y.; Petrich, L.I.

1997-03-25T23:59:59.000Z

338

Atmospheric Radiation Measurement (ARM) Data from Specific Instruments Used in the ARM Program  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

ARM is known for its comprehensive set of world-class, and in some cases, unique, instruments available for use by the global scientific community. In addition to the ARM instruments, the ARM Climate Research Facility identifies and acquires a wide variety of data including model, satellite, and surface data, from "external instruments," to augment the data being generated within the program. External instruments belong to organizations that are outside of the ARM Program. Field campaign instruments are another source of data used to augment routine observations. The huge archive of ARM data can be organized by instrument categories into twelve "collections:" Aerosols, Airborne Observations, Atmospheric Carbon, Atmospheric Profiling, Cloud Properties, Derived Quantities and Models, Ocean Observations, Radiometric, Satellite Observations, Surface Meteorology, Surface/Subsurface Properties, and Other. Clicking on one of the instrument categories leads to a page that breaks that category down into sub-categories. For example, "Atmospheric Profiling" is broken down into ARM instruments (with 11 subsets), External Instruments (with 6 subsets), and Field Campaign Instruments (with 42 subsets). Each of the subset links, in turn, leads to detailed information pages and links to specific data streams. Users will be requested to create a password, but the data files are free for viewing and downloading.

339

Theory of angular dispersive imaging hard x-ray spectrographs  

E-Print Network [OSTI]

A spectrograph is an optical instrument that disperses photons of different energies into distinct directions and space locations, and images photon spectra on a position-sensitive detector. Spectrographs consist of collimating, angular dispersive, and focusing optical elements. Bragg reflecting crystals arranged in an asymmetric scattering geometry are used as the dispersing elements. A ray-transfer matrix technique is applied to propagate x-rays through the optical elements. Several optical designs of hard x-ray spectrographs are proposed and their performance is analyzed. Spectrographs with an energy resolution of 0.1 meV and a spectral window of imaging up to a few tens of meVs are shown to be feasible for inelastic x-ray scattering (IXS) spectroscopy applications. In another example, a spectrograph with a 1-meV spectral resolution and 85-meV spectral window of imaging is considered for Cu K-edge resonant IXS (RIXS).

Shvyd'ko, Yuri

2015-01-01T23:59:59.000Z

340

Two wide-angle imaging neutral-atom spectrometers  

SciTech Connect (OSTI)

The Two Wide-angle Imaging Neutral-atom Spectrometers (TWINS) mission provides a new capability for stereoscopically imaging the magnetosphere. By imaging the charge exchange neutral atoms over a broad energy range (1 < E , {approximately} 100 keV) using two identical instruments on two widely-spaced high-altitude, high-inclination spacecraft, TWINS will enable the 3-dimensional visualization and the resolution of large scale structures and dynamics within the magnetosphere for the first time. These observations will provide a leap ahead in the understanding of the global aspects of the terrestrial magnetosphere and directly address a number of critical issues in the ``Sun-Earth Connections`` science theme of the NASA Office of Space Science.

McComas, D.J.

1997-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "imaging instrumentation radiobiology" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

A robust algorithm for sky background computation in CCD images  

E-Print Network [OSTI]

In this paper we present a non-interactive algorithm to estimate a representative value for the sky background on CCD images. The method we have devised uses the mode as a robust estimator of the background brightness in sub-windows distributed across the input frame. The presence of contaminating objects is detected through the study of the local intensity distribution function and the perturbed areas are rejected using a statistical criterion which was derived from numerical simulations. The technique has been extensively tested on a large amount of images and it is suitable for fully automatic processing of large data volumes. The implementation we discuss here has been optimized for the ESO-FORS1 instrument, but it can be easily generalized to all CCD imagers with a sufficiently large field of view. The algorithm has been successfully used for the UBVRI ESO-Paranal night sky brightness survey (Patat 2003).

F. Patat

2003-01-27T23:59:59.000Z

342

An Automatic Image Reduction Pipeline for the Advanced Camera for Surveys  

E-Print Network [OSTI]

We have written an automatic image processing pipeline for the Advanced Camera for Surveys (ACS) Guaranteed Time Observation (GTO) program. The pipeline, known as Apsis, supports the different cameras available on the ACS instrument and is written in Python with a flexible object-oriented design that simplifies the incorporation of new pipeline modules. The processing steps include empirical determination of image offsets and rotation, cosmic ray rejection, image combination using the drizzle routine called via the STScI Pyraf package, object detection and photometry using SExtractor, and photometric redshift estimation in the event of multiple bandpasses. The products are encapsulated in XML markup for automated ingestion into the ACS Team archive.

Blakeslee, J P; Meurer, G R; Benítez, N; Magee, D

2002-01-01T23:59:59.000Z

343

An Automatic Image Reduction Pipeline for the Advanced Camera for Surveys  

E-Print Network [OSTI]

We have written an automatic image processing pipeline for the Advanced Camera for Surveys (ACS) Guaranteed Time Observation (GTO) program. The pipeline, known as Apsis, supports the different cameras available on the ACS instrument and is written in Python with a flexible object-oriented design that simplifies the incorporation of new pipeline modules. The processing steps include empirical determination of image offsets and rotation, cosmic ray rejection, image combination using the drizzle routine called via the STScI Pyraf package, object detection and photometry using SExtractor, and photometric redshift estimation in the event of multiple bandpasses. The products are encapsulated in XML markup for automated ingestion into the ACS Team archive.

J. P. Blakeslee; K. R. Anderson; G. R. Meurer; N. Benitez; D. Magee

2002-12-16T23:59:59.000Z

344

Video Toroid Cavity Imager  

DOE Patents [OSTI]

A video toroid cavity imager for in situ measurement of electrochemical properties of an electrolytic material sample includes a cylindrical toroid cavity resonator containing the sample and employs NMR and video imaging for providing high-resolution spectral and visual information of molecular characteristics of the sample on a real-time basis. A large magnetic field is applied to the sample under controlled temperature and pressure conditions to simultaneously provide NMR spectroscopy and video imaging capabilities for investigating electrochemical transformations of materials or the evolution of long-range molecular aggregation during cooling of hydrocarbon melts. The video toroid cavity imager includes a miniature commercial video camera with an adjustable lens, a modified compression coin cell imager with a fiat circular principal detector element, and a sample mounted on a transparent circular glass disk, and provides NMR information as well as a video image of a sample, such as a polymer film, with micrometer resolution.

Gerald, Rex E. II; Sanchez, Jairo; Rathke, Jerome W.

2004-08-10T23:59:59.000Z

345

Adaptive Optics and Lucky Imager (AOLI): presentation and first light  

E-Print Network [OSTI]

In this paper we present the Adaptive Optics Lucky Imager (AOLI), a state-of-the-art instrument which makes use of two well proved techniques for extremely high spatial resolution with ground-based telescopes: Lucky Imaging (LI) and Adaptive Optics (AO). AOLI comprises an AO system, including a low order non-linear curvature wavefront sensor together with a 241 actuators deformable mirror, a science array of four 1024x1024 EMCCDs, allowing a 120x120 down to 36x36 arcseconds field of view, a calibration subsystem and a powerful LI software. Thanks to the revolutionary WFS, AOLI shall have the capability of using faint reference stars ({\\it I\\/} $\\sim$ 16.5-17.5), enabling it to be used over a much wider part of the sky than with common Shack-Hartmann AO systems. This instrument saw first light in September 2013 at William Herschel Telescope. Although the instrument was not complete, these commissioning demonstrated its feasibility, obtaining a FWHM for the best PSF of 0.151$\\pm$0.005 arcsec and a plate scale o...

Velasco, S; Mackay, C; Oscoz, A; King, D L; Crass, J; Díaz-Sánchez, A; Femenía, B; González-Escalera, V; Labadie, L; López, R L; Garrido, A Pérez; Puga, M; Rodríguez-Ramos, L F; Zuther, J

2015-01-01T23:59:59.000Z

346

Small-angle scattering instruments on a 1 MW long pulse spallation source  

SciTech Connect (OSTI)

Two small-angle neutron scattering instruments have been designed and optimized for installation at a 1 MW long pulse spallation source. The first of these instruments allows access to length scales in materials from 10 to 400 {angstrom}, and the second instrument from 40 to 1200 {angstrom}. Design characteristics were determined and optimization was done using the MCLIB Monte Carlo instrument simulation package. The code has been {open_quote}benchmarked{close_quote} by simulating the {open_quote}as-built{close_quote} D11 spectrometer at ILL and a performance comparison of the three instruments was made. Comparisons were made by evaluating the scattered intensity for {delta} scatterers at different Q values for various instrument configurations needed to span a Q-range of 0.0007 - 0.44 {angstrom}{sup {minus}1}.

Olah, G.A.; Hjelm, R.P.; Seeger, P.A.

1995-12-01T23:59:59.000Z

347

Ferroelectric optical image comparator  

DOE Patents [OSTI]

A ferroelectric optical image comparator has a lead lanthanum zirconate titanate thin-film device which is constructed with a semi-transparent or transparent conductive first electrode on one side of the thin film, a conductive metal second electrode on the other side of the thin film, and the second electrode is in contact with a nonconducting substrate. A photoinduced current in the device represents the dot product between a stored image and an image projected onto the first electrode. One-dimensional autocorrelations are performed by measuring this current while displacing the projected image. 7 figures.

Butler, M.A.; Land, C.E.; Martin, S.J.; Pfeifer, K.B.

1993-11-30T23:59:59.000Z

348

EMSL - image superimposition  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

image-superimposition en Magnesium behavior and structural defects in Mg+ ion implanted silicon carbide. http:www.emsl.pnl.govemslwebpublicationsmagnesium-behavior-and-structu...

349

image superimposition | EMSL  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

superimposition image superimposition Leads No leads are available at this time. Magnesium behavior and structural defects in Mg+ ion implanted silicon carbide. Abstract: As a...

350

Restoring functional PET Images using Anatomical MR Images  

E-Print Network [OSTI]

Restoring functional PET Images using Anatomical MR Images Peter Philipsen, Ulrik Kjems, Peter Toft signal to noise ratio and the low spa­ tial resolution in Positron Emission Tomography (PET) images ? And Positron Emission Tomography (PET) Images? ffl Segmentation of MR Images ­ Extraction of important edges

Mosegaard, Klaus

351

Compression of Computer Graphics Images with Image-Based Rendering  

E-Print Network [OSTI]

Compression of Computer Graphics Images with Image-Based Rendering Ilmi Yoon and Ulrich Neumann information from previously rendered images. Images predicted from prior images are combined with a residual-based rendering tech- nique provides accurate motion prediction and accelerates rendering at the same time

Shahabi, Cyrus

352

SINGLE-CRYSTAL SAPPHIRE OPTICAL FIBER SENSOR INSTRUMENTATION  

SciTech Connect (OSTI)

Accurate measurement of temperature is essential for the safe and efficient operation and control of a wide range of industrial processes. Appropriate techniques and instrumentation are needed depending on the temperature measurement requirements in different industrial processes and working environments. Harsh environments are common in many industrial applications. These harsh environments may involve extreme physical conditions, such as high-temperature, high-pressure, corrosive agents, toxicity, strong electromagnetic interference, and high-energy radiation exposure. Due to these severe environmental conditions, conventional temperature sensors are often difficult to apply. This situation has opened a new but challenging opportunity for the sensor society to provide robust, high-performance, and cost-effective temperature sensors capable of operating in those harsh environments. The focus of this research program has been to develop a temperature measurement system for temperature measurements in the primary and secondary stages of slagging gasifiers. For this application the temperature measurement system must be able to withstand the extremely harsh environment posed by the high temperatures and corrosive agents present in these systems. Real-time, accurate and reliable monitoring of temperature for the coal gasification process is important to realize the full economic potential of these gasification systems. Long life and stability of operation in the high temperature environment is essential for the temperature measurement system to ensure the continuous running of the coal gasification system over the long term. In this high temperature and chemically corrosive environment, rather limited high temperature measurement techniques such as high temperature thermocouples and optical/acoustic pyrometers are available, each with their own limitations. In this research program, five different temperature sensing schemes based on the single crystal sapphire material were thoroughly investigated to determine an optimal approach for on-line, real-time, reliable, long-term monitoring of temperatures inside the coal gasification environment. Among these were a sapphire fiber extrinsic Fabry-Perot interferometric (EFPI) sensor; an intensity-measurement based polarimetric sapphire sensor and a broadband polarimetric differential interferometric (BPDI) sapphire sensor. Based on the current evaluation and analysis of the experimental results, the broadband polarimetric differential interferometric (BPDI) sensor system was chosen for further prototype instrumentation development because of it's superior performance compared to the other systems. This approach is based on the self-calibrating measurement of the optical path length differences in a single-crystal sapphire disk, which is a function of both the temperature dependent birefringence and the temperature dependent dimensional changes.

A. Wang; G. Pickrell; R. May

2002-09-10T23:59:59.000Z

353

SINGLE-CRYSTAL SAPPHIRE OPTICAL FIBER SENSOR INSTRUMENTATION  

SciTech Connect (OSTI)

Accurate measurement of temperature is essential for the safe and efficient operation and control of a wide range of industrial processes. Appropriate techniques and instrumentation are needed depending on the temperature measurement requirements in different industrial processes and working environments. Harsh environments are common in many industrial applications. These harsh environments may involve extreme physical conditions, such as high-temperature, high-pressure, corrosive agents, toxicity, strong electromagnetic interference, and high-energy radiation exposure. Due to these severe environmental conditions, conventional temperature sensors are often difficult to apply. This situation has opened a new but challenging opportunity for the sensor society to provide robust, high-performance, and cost-effective temperature sensors capable of operating in those harsh environments. The focus of this research program has been to develop a temperature measurement system for temperature measurements in the primary and secondary stages of slagging gasifiers. For this application the temperature measurement system must be able to withstand the extremely harsh environment posed by the high temperatures and corrosive agents present in these systems. Real-time, accurate and reliable monitoring of temperature for the coal gasification process is important to realize the full economic potential of these gasification systems. Long life and stability of operation in the high temperature environment is essential for the temperature measurement system to ensure the continuous running of the coal gasification system over the long term. In this high temperature and chemically corrosive environment, rather limited high temperature measurement techniques such as high temperature thermocouples and optical/acoustic pyrometers are available, each with their own limitations. In this research program, five different temperature sensing schemes based on the single crystal sapphire material were thoroughly investigated to determine an optimal approach for on-line, real-time, reliable, long-term monitoring of temperatures inside the coal gasification environment. Among these were a sapphire fiber extrinsic Fabry-Perot interferometric (EFPI) sensor; an intensity-measurement based polarimetric sapphire sensor and a broadband polarimetric differential interferometric (BPDI) sapphire sensor. Based on the current evaluation and analysis of the experimental results, the BPDI sensor system was chosen for further prototype instrumentation development because of it's superior performance compared to the other systems. This approach is based on the self-calibrating measurement of the optical path length differences in a single-crystal sapphire disk, which is a function of both the temperature dependent birefringence and the temperature dependent dimensional changes.

A. Wang; G. Pickrell; R. May

2002-10-18T23:59:59.000Z

354

Supplier selection and supplier management improvements at an analytical instrument manufacturing company  

E-Print Network [OSTI]

This thesis addresses the challenges of improving the quality of parts received from suppliers at Waters, an analytical instrument manufacturing company. Preliminary analysis identified improvement opportunities at evaluation ...

He, Yan, M. Eng. Massachusetts Institute of Technology

2014-01-01T23:59:59.000Z

355

Instrumented, Shielded Test Canister System for Evaluation of Spent Nuclear Fuel in Dry Storage  

SciTech Connect (OSTI)

This document describes the development of an instrumented, shielded test canister system to store and monitor aluminum-based spent nuclear duel under dry storage conditions.

Sindelar, R.L.

1999-10-21T23:59:59.000Z

356

E-Print Network 3.0 - autonomous instrument guidance Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Center for Intelligent Systems Research Collection: Engineering 31 Header for SPIE use Robot Design Summary: Instrument Arm) Advanced Control & Autonomy (Autonomous Sample...

357

E-Print Network 3.0 - acrf instrumentation status Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

that measure solar and terrestrial... in April 2002. 4. INSTRUMENT AND SITE MAINTENANCE ACRF field technicians, under the guidance of site opera... all ACRF sites; its...

358

Numerical tools for musical instruments acoustics: analysing nonlinear physical models using continuation  

E-Print Network [OSTI]

self-sustained oscillations. Several physical models (clarinet and saxophone) are formulated the dynamical properties of self-sustained musical instruments using tra- ditional numerical techniques

Boyer, Edmond

359

Instrumentation and Controls Division progress report, July 1, 1990--June 30, 1992  

SciTech Connect (OSTI)

This report discusses research being conducted in the following areas: reactor systems; research instruments; measurement and controls engineering; and technical support.

Eads, B. G.

1993-01-01T23:59:59.000Z

360

Instrumentation and Controls Division progress report, July 1, 1990--June 30, 1992. Volume 1  

SciTech Connect (OSTI)

This report discusses research being conducted in the following areas: reactor systems; research instruments; measurement and controls engineering; and technical support.

Eads, B. G.; Fry, D. N.; Brashear, H. R.; McDonald, D. W.; Miller, D. R.

1993-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "imaging instrumentation radiobiology" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Instrumentation and Controls Division progress report, July 1, 1982-July 1, 1984. Volume 1  

SciTech Connect (OSTI)

Progress is briefly summarized for a large number of projects in the areas of research instruments, measurement and controls engineering, reactor systems, and maintenance management. (LEW)

Klobe, L.W.E. (ed.)

1984-12-01T23:59:59.000Z

362

Alice: The Rosetta Ultraviolet Imaging Spectrograph  

E-Print Network [OSTI]

We describe the design, performance and scientific objectives of the NASA-funded ALICE instrument aboard the ESA Rosetta asteroid flyby/comet rendezvous mission. ALICE is a lightweight, low-power, and low-cost imaging spectrograph optimized for cometary far-ultraviolet (FUV) spectroscopy. It will be the first UV spectrograph to study a comet at close range. It is designed to obtain spatially-resolved spectra of Rosetta mission targets in the 700-2050 A spectral band with a spectral resolution between 8 A and 12 A for extended sources that fill its ~0.05 deg x 6.0 deg field-of-view. ALICE employs an off-axis telescope feeding a 0.15-m normal incidence Rowland circle spectrograph with a concave holographic reflection grating. The imaging microchannel plate detector utilizes dual solar-blind opaque photocathodes (KBr and CsI) and employs a 2 D delay-line readout array. The instrument is controlled by an internal microprocessor. During the prime Rosetta mission, ALICE will characterize comet 67P/Churyumov-Gerasimenko's coma, its nucleus, and the nucleus/coma coupling; during cruise to the comet, ALICE will make observations of the mission's two asteroid flyby targets and of Mars, its moons, and of Earth's moon. ALICE has already successfully completed the in-flight commissioning phase and is operating normally in flight. It has been characterized in flight with stellar flux calibrations, observations of the Moon during the first Earth fly-by, and observations of comet Linear T7 in 2004 and comet 9P/Tempel 1 during the 2005 Deep Impact comet-collision observing campaign

S. A. Stern; D. C. Slater; J. Scherrer; J. Stone; M. Versteeg; M. F. A'Hearn; J. L. Bertaux; P. D. Feldman; M. C. Festou; J. Wm. Parker; O. H. W. Siegmund

2006-03-21T23:59:59.000Z

363

The HERMES dual-radiator ring imaging Cerenkov detector  

E-Print Network [OSTI]

The construction and use of a dual radiator Ring Imaging Cerenkov(RICH) detector is described. This instrument was developed for the HERMES experiment at DESY which emphasizes measurements of semi-inclusive deep-inelastic scattering. It provides particle identification for pions, kaons, and protons in the momentum range from 2 to 15 GeV, which is essential to these studies. The instrument uses two radiators, C4F10, a heavy fluorocarbon gas, and a wall of silica aerogel tiles. The use of aerogel in a RICH detector has only recently become possible with the development of clear, large homogeneous and hydrophobic aerogel. A lightweight mirror was constructed using a newly perfected technique to make resin-coated carbon-fiber surfaces of optical quality. The photon detector consists of 1934 photomultiplier tubes for each detector half, held in a soft steel matrix to provide shielding against the residual field of the main spectrometer magnet.

Akopov, N Z; Bailey, K; Bernreuther, S; Bianchi, N; Capitani, G P; Carter, P; Cisbani, E; De Leo, R; De Sanctis, E; De Schepper, D; Dzhordzhadze, V; Filippone, B W; Frullani, S; Garibaldi, F; Hansen, J O; Hommez, B; Iodice, M; Jackson, H E; Jung, P; Kaiser, R; Kanesaka, J; Kowalczyk, R; Lagamba, L; Maas, A; Muccifora, V; Nappi, E; Negodaeva, K; Nowak, Wolf-Dieter; O'Connor, T; O'Neill, T G; Potterveld, D H; Ryckbosch, D; Sakemi, Y; Sato, F; Schwind, A; Shibata, T A; Suetsugu, K; Thomas, E; Tytgat, M; Urciuoli, G M; Van de Kerckhove, K; Van de Vyver, R; Yoneyama, S; Zohrabyan, H G; Zhang, L F

2002-01-01T23:59:59.000Z

364

Planck Early Results: The Low Frequency Instrument data processing  

E-Print Network [OSTI]

We describe the data processing pipeline employed by the Low Frequency Instrument (LFI) Data Processing Centre (DPC) to create and characterize the frequency maps used by the ERCSC (Early Release Compact Source Catalogue) first product of Planck to become public. In particular, we discuss the various steps involved in reducing the data, starting from telemetry (TM)packets through to the production of cleaned calibrated timelines and calibrated frequency maps. Data are continuously calibrated using the modulation induced on the mean temperature of the Cosmic Microwave Background Radiation by the proper motion of the spacecraft. The sky signals other than the dipole are removed by an iterative procedure based on simultaneous fitting of calibration parameters and sky maps. Noise properties are estimated from time-ordered data where the sky signal is removed using a Generalized Least Square map-making algorithm. The measured 1/f noise knee-frequencies range from \\sim 100 mHz at 30 GHz to a few tens of mHz at 70 G...

Zacchei, A; Baccigalupi, C; Bersanelli, M; Bonaldi, A; Bonavera, L; Burigana, C; Butler, R C; Cuttaia, F; de Zotti, G; Dick, J; Frailis, M; Galeotta, S; González-Nuevo, J; Górski, K M; Gregorio, A; Keihänen, E; Keskitalo, R; Knoche, J; Kurki-Suonio, H; Lawrence, C R; Leach, S; Leahy, J P; López-Caniego, M; Mandolesi, N; Maris, M; Matthai, F; Meinhold, P R; Mennella, A; Morgante, G; Morisset, N; Natoli, P; Pasian, F; Perrotta, F; Polenta, G; Poutanen, T; Reinecke, M; Ricciardi, S; Rohlfs, R; Sandri, M; Suur-Uski, A -S; Tauber, J A; Tavagnacco, D; Terenzi, L; Tomasi, M; Valiviita, J; Villa, F; Zonca, A; Banday, A J; Barreiro, R B; Bartlett, J G; Bartolo, N; Bedini, L; Bennett, K; Binko, P; Borrill, J; Bouchet, F R; Bremer, M; Cabella, P; Cappellini, B; Chen, X; Colombo, L; Cruz, M; Curto, A; Danese, L; Davies, R D; Davis, R J; de Gasperis, G; de Rosa, A; de Troia, G; Dickinson, C; Diego, J M; Donzelli, S; Dörl, U; Efstathiou, G; En\\sslin, T A; Eriksen, H K; Falvella, M C; Finelli, F; Franceschi, E; Gaier, T C; Gasparo, F; Génova-Santos, R T; Giardino, G; Gómez, F; Gruppuso, A; Hansen, F K; Hell, R; Herranz, D; Hovest, W; Jewell, J; Juvela, M; Kisner, T S; Knox, L; Lähteenmäki, A; Lamarre, J -M; Leonardi, R; León-Tavares, J; Lilje, P B; Lubin, P M; Maggio, G; Marinucci, D; Martínez-González, E; Massardi, M; Matarrese, S; Meharga, M T; Melchiorri, A; Migliaccio, M; Mitra, S; Moss, A; N\\orgaard-Nielsen, H U; Pagano, L; Paladini, R; Paoletti, D; Partridge, B; Pearson, D; Pettorino, V; Pietrobon, D; Prézeau, G; Procopio, P; Puget, J -L; Quercellini, C; Rachen, J P; Rebolo, R; Robbers, G; Rocha, G; Rubi\; Salerno, E; Savelainen, M; Scott, D; Seiffert, M D; Silk, J I; Smoot, G F; Sternberg, J; Stivoli, F; Stompor, R; Tofani, G; Tuovinen, J; Türler, M; Umana, G; Vielva, P; Vittorio, N; Vuerli, C; Wade, L A; Watson, R; White, S D M; Wilkinson, A

2011-01-01T23:59:59.000Z

365

IceCube: An Instrument for Neutrino Astronomy  

E-Print Network [OSTI]

Neutrino astronomy beyond the Sun was first imagined in the late 1950s; by the 1970s, it was realized that kilometer-scale neutrino detectors were required. The first such instrument, IceCube, is near completion and taking data. The IceCube project transforms a cubic kilometer of deep and ultra-transparent Antarctic ice into a particle detector. A total of 5,160 optical sensors are embedded into a gigaton of Antarctic ice to detect the Cherenkov light emitted by secondary particles produced when neutrinos interact with nuclei in the ice. Each optical sensor is a complete data acquisition system, including a phototube, digitization electronics, control and trigger systems and LEDs for calibration. The light patterns reveal the type (flavor) of neutrino interaction and the energy and direction of the neutrino, making neutrino astronomy possible. The scientific missions of IceCube include such varied tasks as the search for sources of cosmic rays, the observation of Galactic supernova explosions, the search for dark matter, and the study of the neutrinos themselves. These reach energies well beyond those produced with accelerator beams. The outline of this review is as follows: Neutrino Astronomy and Kilometer-Scale Detectors. High-Energy Neutrino Telescopes: Methodologies of Neutrino Detection. IceCube Hardware. High-Energy Neutrino Telescopes: Beyond Astronomy. Future Projects

Francis Halzen; Spencer R. Klein

2010-07-07T23:59:59.000Z

366

The IMCA: A field instrument for uranium enrichment measurements  

SciTech Connect (OSTI)

The IMCA (Inspection Multi-Channel Analyzer) is a portable gamma-ray spectrometer designed to measure the enrichment of uranium either in a laboratory or in the field. The IMCA consists of a Canberra InSpector Multi-Channel Analyzer, sodium iodide or a planar germanium detector, and special application software. The system possesses a high degree of automation. The IMCA uses the uranium enrichment meter principle, and is designed to meet the International Atomic Energy Agency (IAEA) requirements for the verification of enriched uranium materials. The IMCA is available with MGA plutonium isotopic analysis software or MGAU uranium analysis software as well. In this paper, the authors present a detailed description of the hardware and software of the IMCA system, as well as results from preliminary measurements testing compliance of IMCA with IAEA requirements using uranium standards and UF6 cylinders. Measurements performed on UF6 cylinders in the field under variable environmental conditions (temperatures ranging from 0 to 35 C) have shown that good results can be achieved. The enrichment of UF6 contained in the cylinder is determined by using calibration constants generated from an instrument calibration, using traceable uranium oxide standards, performed in the laboratory under controlled environmental conditions. The IMCA software is designed to make the necessary matrix and container corrections to ensure that accurate results are achieved in the field.

Gardner, G.H.; Koskelo, M.; Moeslinger, M. [Canberra Industries, Meriden, CT (United States); Mayer, R.L. II; McGinnis, B.R. [Lockheed Martin Utility Services, Piketon, OH (United States). Portsmouth Gaseous Diffusion Plant; Wishard, B. [International Atomic Energy Agency, Vienna (Austria)

1996-12-31T23:59:59.000Z

367

Neutron cross section standards and instrumentation. Annual report  

SciTech Connect (OSTI)

The objective of this interagency program is to provide accurate neutron interaction measurements for the US Department of Energy nuclear programs which include waste disposal, fusion, safeguards, defense, fission, and personnel protection. These measurements are also useful to other energy programs which indirectly use the unique properties of the neutron for diagnostic and analytical purposes. The work includes the measurement of reference cross sections and related neutron data employing unique facilities and capabilities at NIST and other laboratories as required; leadership and participation in international intercomparisons and collaborations; the preservation of standard reference deposits and the development of improved neutron detectors and measurement methods. A related and essential element of the program is critical evaluation of neutron interaction data including international coordinations. Data testing of critical data for important applications is included. The program is jointly supported by the Department of Energy and the National Institute of Standards and Technology. This report from the National Institute of Standards and Technology contains a summary of the accomplishments of the Neutron Cross Section Standards and Instrumentation Project during the third year of this three-year interagency agreement. The proposed program and required budget for the following three years are also presented. The program continues the shifts in priority instituted in order to broaden the program base.

Wasson, O.A.

1993-07-01T23:59:59.000Z

368

IceCube: An Instrument for Neutrino Astronomy  

SciTech Connect (OSTI)

Neutrino astronomy beyond the Sun was first imagined in the late 1950s; by the 1970s, it was realized that kilometer-scale neutrino detectors were required. The first such instrument, IceCube, is near completion and taking data. The IceCube project transforms a cubic kilometer of deep and ultra-transparent Antarctic ice into a particle detector. A total of 5,160 optical sensors are embedded into a gigaton of Antarctic ice to detect the Cherenkov light emitted by secondary particles produced when neutrinos interact with nuclei in the ice. Each optical sensor is a complete data acquisition system, including a phototube, digitization electronics, control and trigger systems and LEDs for calibration. The light patterns reveal the type (flavor) of neutrino interaction and the energy and direction of the neutrino, making neutrino astronomy possible. The scientific missions of IceCube include such varied tasks as the search for sources of cosmic rays, the observation of Galactic supernova explosions, the search for dark matter, and the study of the neutrinos themselves. These reach energies well beyond those produced with accelerator beams.

IceCube Collaboration; Halzen, F.; Klein, S.

2010-06-04T23:59:59.000Z

369

Enhanced in-pile instrumentation at the advanced test reactor  

SciTech Connect (OSTI)

Many of the sensors deployed at materials and test reactors cannot withstand the high flux/high temperature test conditions often requested by users at U.S. test reactors, such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory. To address this issue, an instrumentation development effort was initiated as part of the ATR National Scientific User Facility in 2007 to support the development and deployment of enhanced in-pile sensors. This paper reports results from this effort. Specifically, this paper identifies the types of sensors currently available to support in-pile irradiations and those sensors currently available to ATR users. Accomplishments from new sensor technology deployment efforts are highlighted by describing new temperature and thermal conductivity sensors now available to ATR users. Efforts to deploy enhanced in-pile sensors for detecting elongation and realtime flux detectors are also reported, and recently-initiated research to evaluate the viability of advanced technologies to provide enhanced accuracy for measuring key parameters during irradiation testing are noted. (authors)

Rempe, J. L.; Knudson, D. L.; Daw, J. E.; Unruh, T.; Chase, B. M.; Palmer, J.; Condie, K. G.; Davis, K. L. [Idaho National Laboratory, MS 3840, P.O. Box 1625, Idaho Falls, ID 83415 (United States)

2011-07-01T23:59:59.000Z

370

Enhanced In-Pile Instrumentation at the Advanced Test Reactor  

SciTech Connect (OSTI)

Many of the sensors deployed at materials and test reactors cannot withstand the high flux/high temperature test conditions often requested by users at U.S. test reactors, such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory. To address this issue, an instrumentation development effort was initiated as part of the ATR National Scientific User Facility in 2007 to support the development and deployment of enhanced in-pile sensors. This paper provides an update on this effort. Specifically, this paper identifies the types of sensors currently available to support in-pile irradiations and those sensors currently available to ATR users. Accomplishments from new sensor technology deployment efforts are highlighted by describing new temperature and thermal conductivity sensors now available to ATR users. Efforts to deploy enhanced in-pile sensors for detecting elongation and real-time flux detectors are also reported, and recently-initiated research to evaluate the viability of advanced technologies to provide enhanced accuracy for measuring key parameters during irradiation testing are noted.

Joy Rempe; Darrell Knudson; Joshua Daw; Troy Unruh; Benjamin Chase; Kurt Davis; Robert Schley; Steven Taylor

2012-08-01T23:59:59.000Z

371

Optical Fiber High Temperature Sensor Instrumentation for Energy Intensive Industries  

SciTech Connect (OSTI)

This report summarizes technical progress during the program “Optical Fiber High Temperature Sensor Instrumentation for Energy Intensive Industries”, performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The objective of this program was to use technology recently invented at Virginia Tech to develop and demonstrate the application of self-calibrating optical fiber temperature and pressure sensors to several key energy-intensive industries where conventional, commercially available sensors exhibit greatly abbreviated lifetimes due primarily to environmental degradation. A number of significant technologies were developed under this program, including • a laser bonded silica high temperature fiber sensor with a high temperature capability up to 700°C and a frequency response up to 150 kHz, • the world’s smallest fiber Fabry-Perot high temperature pressure sensor (125 x 20 ?m) with 700°C capability, • UV-induced intrinsic Fabry-Perot interferometric sensors for distributed measurement, • a single crystal sapphire fiber-based sensor with a temperature capability up to 1600°C. These technologies have been well demonstrated and laboratory tested. Our work plan included conducting major field tests of these technologies at EPRI, Corning, Pratt & Whitney, and Global Energy; field validation of the technology is critical to ensuring its usefulness to U.S. industries. Unfortunately, due to budget cuts, DOE was unable to follow through with its funding commitment to support Energy Efficiency Science Initiative projects and this final phase was eliminated.

Cooper, Kristie L.; Wang, Anbo; Pickrell, Gary R.

2006-11-14T23:59:59.000Z

372

Six-degree-of-freedom Sensor Fish design and instrumentation  

SciTech Connect (OSTI)

Fish passing through dams may be injured or killed despite advances in turbine design, project operations and other fish bypass systems. The Six-degree-of-freedom (6DOF) Sensor Fish device is an autonomous sensor package designed to characterize the physical conditions and physical stresses fish are exposed to when they pass through complex hydraulic environments. It has been used to identify the locations and operations where conditions are severe enough to injure or kill fish. During the design process, a set of governing equations of motion for the device was derived and simulated in order to understand the design implications of instrument selection and placement within the body of the device. The sensor package includes three rotation sensors, three acceleration sensors, a pressure sensor, and a temperature sensor with a sampling frequency of 2,000 Hz. Its housing is constructed of clear polycarbonate plastic. It is 24.5 mm in diameter and 90 mm in length, weighs about 43 grams, similar to the size and density of a yearling salmon smolt. The relative errors of both the linear acceleration and angular velocity measurements were determined to be less than 5% from laboratory acceptance tests. Since its development in 2005, the 6DOF Sensor Fish device has been successfully deployed at many major dams in the United States.

Deng, Zhiqun; Carlson, Thomas J.; Duncan, Joanne P.; Richmond, Marshall C.

2007-12-19T23:59:59.000Z

373

Enhanced In-Pile Instrumentation at the Advanced Test Reactor  

SciTech Connect (OSTI)

Many of the sensors deployed at materials and test reactors cannot withstand the high flux/high temperature test conditions often requested by users at U.S. test reactors, such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL). To address this issue, an instrumentation development effort was initiated as part of the ATR National Scientific User Facility (NSUF) in 2007 to support the development and deployment of enhanced in-pile sensors. This paper reports results from this effort. Specifically, this paper identifies the types of sensors currently available to support in-pile irradiations and those sensors currently available to ATR users. Accomplishments from new sensor technology deployment efforts are highlighted by describing new temperature and thermal conductivity sensors now available to ATR users. Efforts to deploy enhanced in-pile sensors for detecting elongation and real-time flux detectors are also reported, and recently-initiated research to evaluate the viability of advanced technologies to provide enhanced accuracy for measuring key parameters during irradiation testing are noted.

J. Rempe; D. Knudson; J. Daw; T. Unruh; B. Chase; K. Condie

2011-06-01T23:59:59.000Z

374

DOUBLE MAJORS Imaging Science + ...  

E-Print Network [OSTI]

DOUBLE MAJORS Imaging Science + ... Applied Mathematics Biomedical Sciences Computer Science Undergraduate Research Internships and Cooperative Education (Co-op) (optional) Study Abroad WHY IMAGING SCIENCE Science: BS, MS, PhD Color Science: MS, PhD BS + MS/PhD Combos HUMAN VISION BIO- MEDICAL ASTRO- PHYSICS

Zanibbi, Richard

375

Directional Multiresolution Image Representations  

E-Print Network [OSTI]

) are not necessarily best suited for images. Thus, there is a strong motivation to search for more powerful schemes consid´er´ees comme de bonnes repr´esentations des images na- turelles. Le lien entre les courbelettes et

Do, Minh N.

376

Medical imaging systems  

DOE Patents [OSTI]

A medical imaging system provides simultaneous rendering of visible light and fluorescent images. The system may employ dyes in a small-molecule form that remains in a subject's blood stream for several minutes, allowing real-time imaging of the subject's circulatory system superimposed upon a conventional, visible light image of the subject. The system may also employ dyes or other fluorescent substances associated with antibodies, antibody fragments, or ligands that accumulate within a region of diagnostic significance. In one embodiment, the system provides an excitation light source to excite the fluorescent substance and a visible light source for general illumination within the same optical guide that is used to capture images. In another embodiment, the system is configured for use in open surgical procedures by providing an operating area that is closed to ambient light. More broadly, the systems described herein may be used in imaging applications where a visible light image may be usefully supplemented by an image formed from fluorescent emissions from a fluorescent substance that marks areas of functional interest.

Frangioni, John V. (Wayland, MA)

2012-07-24T23:59:59.000Z

377

Heart imaging method  

DOE Patents [OSTI]

A method for providing an image of the human heart's electrical system derives time-of-flight data from an array of EKG electrodes and this data is transformed into phase information. The phase information, treated as a hologram, is reconstructed to provide an image in one or two dimensions of the electrical system of the functioning heart.

Collins, H. Dale (Richland, WA); Gribble, R. Parks (Richland, WA); Busse, Lawrence J. (Littleton, CO)

1991-01-01T23:59:59.000Z

378

Fluorescent image tracking velocimeter  

DOE Patents [OSTI]

A multiple-exposure fluorescent image tracking velocimeter (FITV) detects and measures the motion (trajectory, direction and velocity) of small particles close to light scattering surfaces. The small particles may follow the motion of a carrier medium such as a liquid, gas or multi-phase mixture, allowing the motion of the carrier medium to be observed, measured and recorded. The main components of the FITV include: (1) fluorescent particles; (2) a pulsed fluorescent excitation laser source; (3) an imaging camera; and (4) an image analyzer. FITV uses fluorescing particles excited by visible laser light to enhance particle image detectability near light scattering surfaces. The excitation laser light is filtered out before reaching the imaging camera allowing the fluoresced wavelengths emitted by the particles to be detected and recorded by the camera. FITV employs multiple exposures of a single camera image by pulsing the excitation laser light for producing a series of images of each particle along its trajectory. The time-lapsed image may be used to determine trajectory and velocity and the exposures may be coded to derive directional information.

Shaffer, Franklin D. (Library, PA)

1994-01-01T23:59:59.000Z

379

Adaptive wiener image restoration kernel  

DOE Patents [OSTI]

A method and device for restoration of electro-optical image data using an adaptive Wiener filter begins with constructing imaging system Optical Transfer Function, and the Fourier Transformations of the noise and the image. A spatial representation of the imaged object is restored by spatial convolution of the image using a Wiener restoration kernel.

Yuan, Ding (Henderson, NV)

2007-06-05T23:59:59.000Z

380

Time encoded radiation imaging  

DOE Patents [OSTI]

The various technologies presented herein relate to detecting nuclear material at a large stand-off distance. An imaging system is presented which can detect nuclear material by utilizing time encoded imaging relating to maximum and minimum radiation particle counts rates. The imaging system is integrated with a data acquisition system that can utilize variations in photon pulse shape to discriminate between neutron and gamma-ray interactions. Modulation in the detected neutron count rates as a function of the angular orientation of the detector due to attenuation of neighboring detectors is utilized to reconstruct the neutron source distribution over 360 degrees around the imaging system. Neutrons (e.g., fast neutrons) and/or gamma-rays are incident upon scintillation material in the imager, the photons generated by the scintillation material are converted to electrical energy from which the respective neutrons/gamma rays can be determined and, accordingly, a direction to, and the location of, a radiation source identified.

Marleau, Peter; Brubaker, Erik; Kiff, Scott

2014-10-21T23:59:59.000Z

Note: This page contains sample records for the topic "imaging instrumentation radiobiology" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Human genome sequencing with direct x-ray holographic imaging  

SciTech Connect (OSTI)

Direct holographic imaging of biological materials is widely applicable to the study of the structure, properties and action of genetic material. This particular application involves the sequencing of the human genome where prospective genomic imaging technology is composed of three subtechnologies, name an x-ray holographic camera, suitable chemistry and enzymology for the preparation of tagged DNA samples, and the illuminator in the form of an x-ray laser. We report appropriate x-ray camera, embodied by the instrument developed by MCR, is available and that suitable chemical and enzymatic procedures exist for the preparation of the necessary tagged DNA strands. Concerning the future development of the x-ray illuminator. We find that a practical small scale x-ray light source is indeed feasible. This outcome requires the use of unconventional physical processes in order to achieve the necessary power-compression in the amplifying medium. The understanding of these new physical mechanisms is developing rapidly. Importantly, although the x-ray source does not currently exist, the understanding of these new physical mechanisms is developing rapidly and the research has established the basic scaling laws that will determine the properties of the x-ray illuminator. When this x-ray source becomes available, an extremely rapid and cost effective instrument for 3-D imaging of biological materials can be applied to a wide range of biological structural assays, including the base-pair sequencing of the human genome and many questions regarding its higher levels of organization.

Rhodes, C.K.

1993-06-08T23:59:59.000Z

382

Validation of Ozone Monitoring Instrument nitrogen dioxide columns E. A. Celarier,1  

E-Print Network [OSTI]

Validation of Ozone Monitoring Instrument nitrogen dioxide columns E. A. Celarier,1 E. J. Brinksma the standard nitrogen dioxide (NO2) data product (Version 1.0.), which is based on measurements made), Validation of Ozone Monitoring Instrument nitrogen dioxide columns, J. Geophys. Res., 113, D15S15, doi:10

383

The Static and Dynamic Efficiency of Instruments of Promotion of Renewables Dominique FINON and Philippe MENANTEAU*  

E-Print Network [OSTI]

1 The Static and Dynamic Efficiency of Instruments of Promotion of Renewables Dominique FINON and social efficiency of the instruments used to promote renewable energy sources (RES), first from a static and reflected in a high quantitative objective for renewables, sliding scale feed-in tariffs are a good

Paris-Sud XI, Université de

384

Instrumenting Linear Algebra Energy Consumption via On-chip Energy Counters  

E-Print Network [OSTI]

Instrumenting Linear Algebra Energy Consumption via On-chip Energy Counters James Demmel Andrew to lists, requires prior specific permission. #12;Instrumenting linear algebra energy consumption via on consumption is still a prevalent and growing problem within the computing sector. To evaluate energy

California at Berkeley, University of

385

MATERIALS, METHODS, AND INSTRUMENTATION FOR PREPARATIVE-SCALE ISOELECTRIC TRAPPING SEPARATIONS  

E-Print Network [OSTI]

MATERIALS, METHODS, AND INSTRUMENTATION FOR PREPARATIVE- SCALE ISOELECTRIC TRAPPING SEPARATIONS A Dissertation by ROBERT YATES NORTH Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment... of the requirements for the degree of DOCTOR OF PHILOSOPHY May 2009 Major Subject: Chemistry MATERIALS, METHODS, AND INSTRUMENTATION FOR PREPARATIVE- SCALE ISOELECTRIC TRAPPING SEPARATIONS A Dissertation by ROBERT YATES NORTH...

North, Robert Yates

2011-08-08T23:59:59.000Z

386

Instrumenting C programs with Nested Word Swarat Chaudhuri and Rajeev Alur  

E-Print Network [OSTI]

Blast [5] and Slam [2], where a specification is a word automaton (or monitor) with finite- state" of a program and a monitor, in effect instrumenting the program with extra instructions, so that the input automata, and a tool to instrument C code using it. This language ex- tends the Blast specification

Chauduri, Swarat

387

Instrumentation for Neutron Scattering at the Missouri University Research Reactor Paul F. Miceli  

E-Print Network [OSTI]

Instrumentation for Neutron Scattering at the Missouri University Research Reactor Paul F. Miceli Research Reactor (MURR) provides significant thermal neutron flux, which enables neutron scattering]. There are presently 5 instruments located on the beam port floor that are dedicated to neutron scattering: (1) TRIAX

Montfrooij, Wouter

388

SURA-WAVES experiments: calibration of the Cassini/RPWS/HFR instrumentation  

E-Print Network [OSTI]

by both spacecraft are well above the background noise. We use these joint measurements to calibrate by the WAVES instrument is pointed out. 1 Introduction Investigations of the near-Earth space environment/HFR instrument covers the SURA operating frequency range. Seven sessions of SURA transmissions were carried out

Cecconi, Baptiste

389

Instrumentation: Nondestructive Examination for Verification of Canister and Cladding Integrity – FY2014 Status Update  

SciTech Connect (OSTI)

This report documents FY14 efforts for two instrumentation subtasks under storage and transportation. These instrumentation tasks relate to developing effective nondestructive evaluation (NDE) methods and techniques to (1) verify the integrity of metal canisters for the storage of used nuclear fuel (UNF) and to (2) verify the integrity of dry storage cask internals.

Meyer, Ryan M.; Suter, Jonathan D.; Jones, Anthony M.

2014-09-12T23:59:59.000Z

390

A climate sensitivity estimate using Bayesian fusion of instrumental observations and an Earth System model  

E-Print Network [OSTI]

sensitivity estimate using Bayesian fusion of instrumental observations and an Earth System model, J. Geophys System model Roman Olson,1 Ryan Sriver,1 Marlos Goes,2,3 Nathan M. Urban,4,5 H. Damon Matthews,6 MuraliA climate sensitivity estimate using Bayesian fusion of instrumental observations and an Earth

391

An Active Motion Compensation Instrument for Beating Heart Mitral Valve Surgery  

E-Print Network [OSTI]

An Active Motion Compensation Instrument for Beating Heart Mitral Valve Surgery Daniel T. Kettler) is described. The resulting instrument was tested in user trials under a series of positional error bandwidth, creating a wrist that can operate in the restricted workspace within the heart, and ensuring

392

A new collimator design for energetic neutral atom instruments Michael A. Gruntman  

E-Print Network [OSTI]

A new collimator design for energetic neutral atom instruments Michael A. Gruntman Department (Received 31 August 1993; accepted 3 December 1993) A new type of collimator design is described for energetic neutral atom instruments for space research applications. The collimator consists of annular

Gruntman, Mike

393

Draft (12-01-2006): GHRS Instrument Science Report No. 92 Final reprocessing of GHRS data  

E-Print Network [OSTI]

instrument team members are gone or busy supporting other instruments ­ we were facing the danger of losing for GHRS and so the files in the Archive were static and did not get reprocessed as better reference files came along later in the mission. We wanted to process the entire GHRS holding with a consistent set

Sirianni, Marco

394

388 Biomedical Instrumentation & Technology September/October 2011 Columns and Departments  

E-Print Network [OSTI]

388 Biomedical Instrumentation & Technology September/October 2011 Columns and Departments When) as a biomedical equipment technician in 1999, he remembers being presented with the organization's strategic plan written permission from AAMI. #12;389Biomedical Instrumentation & Technology September/October 2011

Hayden, Nancy J.

395

Instrumentation and Controls Division biennial progress report, September 1, 1978-September 1, 1980  

SciTech Connect (OSTI)

Brief summaries of research work are presented in the following section: overview of the ORNL Instrumentation and Controls Division activities; new developments and methods; reactor instrumentation and controls; measurement and control engineering; electronic engineering; maintenance; studies; services; and development; and division achievements.

Sadowski, G.S. (comp.)

1981-06-01T23:59:59.000Z

396

Impact of Smoke Exposure on Digital Instrumentation and Control  

SciTech Connect (OSTI)

Smoke can cause interruptions and upsets in active electronics. Because nuclear power plants are replacing analog with digital instrumentation and control systems, qualification guidelines for new systems are being reviewed for severe environments such as smoke and electromagnetic interference. Active digital systems, individual components, and active circuits have been exposed to smoke in a program sponsored by the U.S. Nuclear Regulatory Commission. The circuits and systems were all monitored during the smoke exposure, indicating any immediate effects of the smoke. The results of previous smoke exposure studies have been reported in various publications. The major immediate effect of smoke has been to increase leakage currents and to cause momentary upsets and failures in digital systems. This paper presents new results from conformal coatings, memory chips, and hard drive tests.The best conformal coatings were found to be polyurethane, parylene, and acrylic (when applied by dipping). Conformal coatings can reduce smoke-induced leakage currents and protect against metal loss through corrosion. However conformal coatings are typically flammable, so they do increase material flammability. Some of the low-voltage biased memory chips failed during a combination of high smoke and high humidity. Typically, smoke along with heat and humidity is expected during fire, rather than smoke alone. Thus, due to high sensitivity of digital circuits to heat and humidity, it is hypothesized that the impact of smoke may be secondary.Low-voltage (3.3-V) static random-access memory (SRAMs) were found to be the most vulnerable to smoke. Higher bias voltages decrease the likelihood of failure. Erasable programmable read-only memory (EPROMs) and nonvolatile SRAMs were very smoke tolerant. Failures of the SRAMs occurred when two conditions were present: high density of smoke and high humidity. As the high humidity was present for only part of the test, the failures were intermittent. All of the chips that failed during the test recovered after enough venting.Hard disks were tested in severe environments but did not fail during the 2 h of monitoring.While the results of the tests documented in this report confirm that digital circuits can indeed be vulnerable to smoke, there is currently no practical, repeatable testing methodology, so it is not feasible to assess smoke susceptibility as part of environmental qualification. As a result, the most reasonable approach to minimizing smoke susceptibility is to employ design, implementation, and procedural practices that can reduce the possibility of smoke exposure and enhance smoke tolerance. Traditional approaches to mitigate its effects in digital safety instrumentation and control, such as redundancy, separation, defense in depth, as well as adherence to standards (e.g., the Institute of Electrical and Electronics Engineers' IEEE 384) and the Code of Federal Regulations Appendix R of 10 CFR 50, should continue to be applied.

Tanaka, Tina J. [Sandia National Laboratories (United States); Nowlen, Steven P. [Sandia National Laboratories (United States); Korsah, Kofi [Oak Ridge National Laboratory (United States); Wood, Richard T. [Oak Ridge National Laboratory (United States); Antonescu, Christina E. [U.S. Nuclear Regulatory Commission (United States)

2003-08-15T23:59:59.000Z

397

Polarization transfer NMR imaging  

DOE Patents [OSTI]

A nuclear magnetic resonance (NMR) image is obtained with spatial information modulated by chemical information. The modulation is obtained through polarization transfer from a first element representing the desired chemical, or functional, information, which is covalently bonded and spin-spin coupled with a second element effective to provide the imaging data. First and second rf pulses are provided at first and second frequencies for exciting the imaging and functional elements, with imaging gradients applied therebetween to spatially separate the nuclei response for imaging. The second rf pulse is applied at a time after the first pulse which is the inverse of the spin coupling constant to select the transfer element nuclei which are spin coupled to the functional element nuclei for imaging. In a particular application, compounds such as glucose, lactate, or lactose, can be labeled with .sup.13 C and metabolic processes involving the compounds can be imaged with the sensitivity of .sup.1 H and the selectivity of .sup.13 C.

Sillerud, Laurel O. (Los Alamos, NM); van Hulsteyn, David B. (Santa Fe, NM)

1990-01-01T23:59:59.000Z

398

PVUSA instrumentation and data analysis techniques for photovoltaic systems  

SciTech Connect (OSTI)

The Photovoltaics for Utility Scale Applications (PVUSA) project tests two types of PV systems at the main test site in Davis, California: new module technologies fielded as 20-kW Emerging Module Technology (EMT) arrays and more mature technologies fielded as 70- to 500-kW turnkey Utility-Scale (US) systems. PVUSA members have also installed systems in their service areas. Designed appropriately, data acquisition systems (DASs) can be a convenient and reliable means of assessing system performance, value, and health. Improperly designed, they can be complicated, difficult to use and maintain, and provide data of questionable validity. This report documents PVUSA PV system instrumentation and data analysis techniques and lessons learned. The report is intended to assist utility engineers, PV system designers, and project managers in establishing an objective, then, through a logical series of topics, facilitate selection and design of a DAS to meet the objective. Report sections include Performance Reporting Objectives (including operational versus research DAS), Recommended Measurements, Measurement Techniques, Calibration Issues, and Data Processing and Analysis Techniques. Conclusions and recommendations based on the several years of operation and performance monitoring are offered. This report is one in a series of 1994--1995 PVUSA reports documenting PVUSA lessons learned at the demonstration sites in Davis and Kerman, California. Other topical reports address: five-year assessment of EMTs; validation of the Kerman 500-kW grid support PV plant benefits; construction and safety experience in installing and operating PV systems; balance-of-system design and costs; procurement, acceptance, and rating practices for PV power plants; experience with power conditioning units and power quality.

Newmiller, J.; Hutchinson, P.; Townsend, T.; Whitaker, C.

1995-10-01T23:59:59.000Z

399

Future Vision for Instrumentation, Information and Control Modernization  

SciTech Connect (OSTI)

A Future Vision of a transformed nuclear plant operating model based on an integrated digital environment has been developed as part of the Advanced Instrumentation, Information, and Control (II&C) research pathway, under the Light Water Reactor (LWR) Sustainability Program. This is a research and development program sponsored by the U.S. Department of Energy (DOE), performed in close collaboration with the nuclear utility industry, to provide the technical foundations for licensing and managing the long-term, safe and economical operation of current nuclear power plants. II&C has been identified as a potential life-limiting issue for the domestic LWR fleet in addressing the reliability and aging concerns of the legacy systems in service today. The Future Vision is based on a digital architecture that encompasses all aspects of plant operations and support, integrating plant systems, plant work processes, and plant workers in a seamless digital environment to enhance nuclear safety, increase productivity, and improve overall plant performance. Pilot projects are being conducted as the means for industry to gain confidence in these new technologies for use in nuclear plant work activities. The pilot projects introduce new digital technologies into the nuclear plant operating environment at host operating plants to demonstrate and validate them for production usage. In turn, the pilot project technologies serve as the stepping stones to the eventual seamless digital environment as described in the Future Vision. Initial project results confirm that the technologies can address provide substantial efficiency and human performance benefits while resolving the reliability and aging concerns.

Ken D. Thomas

2012-05-01T23:59:59.000Z

400

Instrumentation and Controls Division progress report, September 1, 1980-July 1, 1982  

SciTech Connect (OSTI)

Activities are reported by the Reactor Systems Section, Research Instrument Section, and the Measurement and Controls Engineering Section. Reactor system activities include dynamic analysis, survillanc and diagnostic methods, design and evaluation, detectors, facilities support, process instrumentation development, and special assignments. Activities in the Research Instrument Section include the Navy-ORNL RADIAC development program, advanced ..gamma.. and x ray detector systems, neutron detection and subcriticality measurements, circuit development, position-sensitive detectors, stand-alone computers, environmental monitoring-detectors and systems, plant security, engineering support for fusion energy division, engineering support for accelerator physics, and communications: radio, closed-circuit tv, and computer. Activities in the Measurement and Controls Engineering Section include the AVLIS program; gas centrifuge enrichment technology support; Advanced Instrumentation for Reflood Studies (AIDRS) program; instrumentation development support for fuel reprocessing; in-core experiments and reactor systems; energy, conservation, and electric power systems; computer systems; measurements research; and fossil energy studies Publications are listed. (WHK)

Klobe, L.E.E. (ed.)

1982-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "imaging instrumentation radiobiology" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Nuclear medicine imaging system  

DOE Patents [OSTI]

It is an object of this invention to provide a nuclear imaging system having the versatility to do positron annihilation studies, rotating single or opposed camera gamma emission studies, and orthogonal gamma emission studies. It is a further object of this invention to provide an imaging system having the capability for orthogonal dual multipinhole tomography. It is another object of this invention to provide a nuclear imaging system in which all available energy data, as well as patient physiological data, are acquired simultaneously in list mode.

Bennett, G.W.; Brill, A.B.; Bizais, Y.J.C.; Rowe, R.W.; Zubal, I.G.

1983-03-11T23:59:59.000Z

402

Image portion identification methods, image parsing methods, image parsing systems, and articles of manufacture  

DOE Patents [OSTI]

Image portion identification methods, image parsing methods, image parsing systems, and articles of manufacture are described. According to one embodiment, an image portion identification method includes accessing data regarding an image depicting a plurality of biological substrates corresponding to at least one biological sample and indicating presence of at least one biological indicator within the biological sample and, using processing circuitry, automatically identifying a portion of the image depicting one of the biological substrates but not others of the biological substrates.

Lassahn, Gordon D.; Lancaster, Gregory D.; Apel, William A.; Thompson, Vicki S.

2013-01-08T23:59:59.000Z

403

Photothermal imaging scanning microscopy  

DOE Patents [OSTI]

Photothermal Imaging Scanning Microscopy produces a rapid, thermal-based, non-destructive characterization apparatus. Also, a photothermal characterization method of surface and subsurface features includes micron and nanoscale spatial resolution of meter-sized optical materials.

Chinn, Diane (Pleasanton, CA); Stolz, Christopher J. (Lathrop, CA); Wu, Zhouling (Pleasanton, CA); Huber, Robert (Discovery Bay, CA); Weinzapfel, Carolyn (Tracy, CA)

2006-07-11T23:59:59.000Z

404

JOB OPPORTUNITIES Breast imaging  

E-Print Network [OSTI]

Genitourinary Radiology Head and Neck Radiology Musculoskeletal Radiology Neuroradiology Pediatric RadiologyJOB OPPORTUNITIES Breast imaging Chest Radiology Emergency Radiology Gastrointestinal Radiology Interventional Radiology Nuclear Radiology Radiation Oncology What Can I Do With a Major in... Radiological

Jiang, Huiqiang

405

THERMAL NEUTRON BACKSCATTER IMAGING.  

SciTech Connect (OSTI)

Objects of various shapes, with some appreciable hydrogen content, were exposed to fast neutrons from a pulsed D-T generator, resulting in a partially-moderated spectrum of backscattered neutrons. The thermal component of the backscatter was used to form images of the objects by means of a coded aperture thermal neutron imaging system. Timing signals from the neutron generator were used to gate the detection system so as to record only events consistent with thermal neutrons traveling the distance between the target and the detector. It was shown that this time-of-flight method provided a significant improvement in image contrast compared to counting all events detected by the position-sensitive {sup 3}He proportional chamber used in the imager. The technique may have application in the detection and shape-determination of land mines, particularly non-metallic types.

VANIER,P.; FORMAN,L.; HUNTER,S.; HARRIS,E.; SMITH,G.

2004-10-16T23:59:59.000Z

406

Overview of Image Reconstruction  

SciTech Connect (OSTI)

Image reconstruction (or computerized tomography, etc.) is any process whereby a function, f, on Rn is estimated from empirical data pertaining to its integrals, ∫f(x) dx, for some collection of hyperplanes of dimension k < n. The paper begins with background information on how image reconstruction problems have arisen in practice, and describes some of the application areas of past or current interest; these include radioastronomy, optics, radiology and nuclear medicine, electron microscopy, acoustical imaging, geophysical tomography, nondestructive testing, and NMR zeugmatography. Then the various reconstruction algorithms are discussed in five classes: summation, or simple back-projection; convolution, or filtered back-projection; Fourier and other functional transforms; orthogonal function series expansion; and iterative methods. Certain more technical mathematical aspects of image reconstruction are considered from the standpoint of uniqueness, consistency, and stability of solution. The paper concludes by presenting certain open problems. 73 references. (RWR)

Marr, R.B.

1980-04-01T23:59:59.000Z

407

Reflective optical imaging system  

DOE Patents [OSTI]

An optical system compatible with short wavelength (extreme ultraviolet) radiation comprising four reflective elements for projecting a mask image onto a substrate. The four optical elements are characterized in order from object to image as convex, concave, convex and concave mirrors. The optical system is particularly suited for step and scan lithography methods. The invention increases the slit dimensions associated with ringfield scanning optics, improves wafer throughput and allows higher semiconductor device density.

Shafer, David R. (Fairfield, CT)

2000-01-01T23:59:59.000Z

408

alpha-particle radiobiological experiments: Topics by E-print...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

time projection chamber, the large scale prototype of the NEXT-100 neutrinoless double beta decay experiment, in three different drift electric field configurations. We...

409

Radiobiology of normal rat lung in Boron Neutron Capture Therapy  

E-Print Network [OSTI]

Boron Neutron Capture Therapy (BNCT) is a binary cancer radiation therapy that utilizes biochemical tumor cell targeting and provides a mixed field of high and low Linear Energy Transfer (LET) radiation with differing ...

Kiger, Jingli Liu

2006-01-01T23:59:59.000Z

410

armed forces radiobiology: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Determination Aimed at Control of Service Robot Tachi, Susumu 14 An approach to the design and implementation of ESP courses for the personnel of the Sultan of Oman's Armed...

411

accelerator-based radiobiology facilities: Topics by E-print...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

of suitable neutron sources that are compactible with installation in a hospital enviroment. A low-energy accelerator-based neutron source has the potential for meeting...

412

ALPHA-PARTICLE RADIOBIOLOGICAL EXPERIMENTS USING THIN CR-39 DETECTORS  

E-Print Network [OSTI]

. INTRODUCTION Alpha particles from inhaled radon progeny are the most important source of irradiation

Yu, K.N.

413

Restoring functional PET Images using Anatomical MR Images  

E-Print Network [OSTI]

Restoring functional PET Images using Anatomical MR Images Peter Alshede Philipsen, Ulrik Kjems,uk,pto,lkh@imm.dtu.dk Abstract In this paper we present a Bayesian method to enhance functional 3D PET images using apriori as a true PET­MR result, and further more show how to obtain the desired information from the MR images. 1

Mosegaard, Klaus

414

CRDIAC: Coupled Reactor Depletion Instrument with Automated Control  

SciTech Connect (OSTI)

When modeling the behavior of a nuclear reactor over time, it is important to understand how the isotopes in the reactor will change, or transmute, over that time. This is especially important in the reactor fuel itself. Many nuclear physics modeling codes model how particles interact in the system, but do not model this over time. Thus, another code is used in conjunction with the nuclear physics code to accomplish this. In our code, Monte Carlo N-Particle (MCNP) codes and the Multi Reactor Transmutation Analysis Utility (MRTAU) were chosen as the codes to use. In this way, MCNP would produce the reaction rates in the different isotopes present and MRTAU would use cross sections generated from these reaction rates to determine how the mass of each isotope is lost or gained. Between these two codes, the information must be altered and edited for use. For this, a Python 2.7 script was developed to aid the user in getting the information in the correct forms. This newly developed methodology was called the Coupled Reactor Depletion Instrument with Automated Controls (CRDIAC). As is the case in any newly developed methodology for modeling of physical phenomena, CRDIAC needed to be verified against similar methodology and validated against data taken from an experiment, in our case AFIP-3. AFIP-3 was a reduced enrichment plate type fuel tested in the ATR. We verified our methodology against the MCNP Coupled with ORIGEN2 (MCWO) method and validated our work against the Post Irradiation Examination (PIE) data. When compared to MCWO, the difference in concentration of U-235 throughout Cycle 144A was about 1%. When compared to the PIE data, the average bias for end of life U-235 concentration was about 2%. These results from CRDIAC therefore agree with the MCWO and PIE data, validating and verifying CRDIAC. CRDIAC provides an alternative to using ORIGEN-based methodology, which is useful because CRDIAC's depletion code, MRTAU, uses every available isotope in its depletion, unlike ORIGEN, which only depletes the isotopes specified by the user. This means that depletions done by MRTAU more accurately reflect reality. MRTAU also allows the user to build new isotope data sets, which means any isotope with nuclear data could be depleted, something that would help predict the outcomes of nuclear reaction testing in materials other than fuel, like beryllium or gold.

Steven K. Logan

2012-08-01T23:59:59.000Z

415

R.H. Saunders GS concrete growth mitigation project instrumentation and finite element analysis  

SciTech Connect (OSTI)

In 1991, concrete expansion due to Alkali-Silica Reaction (ASR), was diagnosed as the cause of operational and structural problems at R.H. Saunders Generating Station. Reestablishment of contraction joints between the generating units by cutting slots was initiated in January 1993 to relieve accumulated stresses and allow further expansion without deforming the turbine-generators. An integral part of the remedial measure is the installation of an extensive instrumentation system and development of detailed finite element models of the powerhouse structures. In total, two hundred and thirty five instruments have been installed. The instruments include surface extensometers, borehole extensometers, crackmeters, stressmeters, pendulums, thermocouples, borehole convergence meters and strain gauges. All the instruments are monitored continuously by an Automatic Data Acquisition System (ADAS) which allows instrument data to be evaluated remotely. This instrumentation system is being used to collect data on the structural concrete expansion and response to slot cutting. To complement the instrumentation data, three different finite element models have been developed for use. The models range from a very detailed representation of a single powerhouse unit to a less detailed model of the sixteen-unit powerhouse. The finite element models have been calibrated to reflect measured data and subsequently used to estimate the location and frequency of future cuts.

Adeghe, L.; Hindy, A.; Ho, M.S. [Hydroelectric Business Unit, Ontario Hydro, Toronto, Ontario (Canada)

1995-12-31T23:59:59.000Z

416

Simulation of Imaging Atmospheric Cherenkov Telescopes with CORSIKA and sim_telarray  

E-Print Network [OSTI]

Imaging Atmospheric Cherenkov Telescopes (IACTs) have resulted in a breakthrough in very-high energy (VHE) gamma-ray astrophysics. While early IACT installations faced the problem of detecting any sources at all, current instruments are able to see many sources, often over more than two orders of magnitude in energy. As instruments and analysis methods have matured, the requirements for calibration and modelling of physical and instrumental effects have increased. In this article, a set of Monte Carlo simulation tools is described that attempts to include all relevant effects for IACTs in great detail but aims to achieve this in an efficient and flexible way. These tools were originally developed for the HEGRA IACT system and later adapted for the H.E.S.S. experiment. Their inherent flexibility to describe quite arbitrary IACT systems makes them also an ideal tool for evaluating the potential of future installations. It is in use for design studies of CTA and other projects.

Konrad Bernlohr

2008-08-16T23:59:59.000Z

417

Compton DIV: Using a Compton-Based Gamma-Ray Imager for Design Information Verification of Uranium Enrichment Plants  

SciTech Connect (OSTI)

A feasibility study has been performed to determine the potential usefulness of Compton imaging as a tool for design information verification (DIV) of uranium enrichment plants. Compton imaging is a method of gamma-ray imaging capable of imaging with a 360-degree field of view over a broad range of energies. These systems can image a room (with a time span on the order of one hour) and return a picture of the distribution and composition of radioactive material in that room. The effectiveness of Compton imaging depends on the sensitivity and resolution of the instrument as well the strength and energy of the radioactive material to be imaged. This study combined measurements and simulations to examine the specific issue of UF{sub 6} gas flow in pipes, at various enrichment levels, as well as hold-up resulting from the accumulation of enriched material in those pipes. It was found that current generation imagers could image pipes carrying UF{sub 6} in less than one hour at moderate to high enrichment. Pipes with low enriched gas would require more time. It was also found that hold-up was more amenable to this technique and could be imaged in gram quantities in a fraction of an hour. another questions arises regarding the ability to separately image two pipes spaced closely together. This depends on the capabilities of the instrument in question. These results are described in detail. In addition, suggestions are given as to how to develop Compton imaging as a tool for DIV.

Burks, M; Verbeke, J; Dougan, A; Wang, T; Decman, D

2009-07-04T23:59:59.000Z

418

Tilmeter hydraulic fracture imaging enhancement project: Progress repeort  

SciTech Connect (OSTI)

Over half of all oil & gas production wells drilled in the United States depend upon hydraulic fracturing to sustain or enhance production. However, there is no existing technology that allows detailed near-surface imaging of these hydraulically-driven fractures at depths greater than about 5000 feet. To image hydraulic fractures in the 8000`-10,000` depth range, we are currently redesigning tiltmeter tools in order to deploy the instruments deeper to escape the cultural/natural surface noise that often masks the hydrofrac signal. With nearly noise-free data, we should be in a better position to separate the earth-tide signal from the tiltmeter signal and investigate fine-scale hydraulic fracturing processes.

Castillo, D.A. [Lawrence Livermore National Lab., CA (United States); Wright, C.A.; Conant, R.A. [and others

1995-12-31T23:59:59.000Z

419

The University of Hawaii Wide Field Imager (UHWFI)  

E-Print Network [OSTI]

The University of Hawaii Wide-Field Imager (UHWFI) is a focal compressor system designed to project the full half-degree field of the UH 2.2 m telescope onto the refurbished UH 8Kx8K CCD camera. The optics use Ohara glasses and are mounted in an oil-filled cell to minimize light losses and ghost images from the large number of internal lens surfaces. The UHWFI is equipped with a six-position filter wheel and a rotating sector blade shutter,both driven by stepper motors. The instrument saw first light in 2004 in an engineering mode. After filling the lens cell with index matching oil, integration of all software components into the user interface, tuning of the CCD performance, and the purchase of the final filter set, UHWFI is now fully commissioned at the UH 2.2 m telescope.

Klaus W. Hodapp; Andreas Seifahrt; Gerard A. Luppino; Richard Wainscoat; Ed Sousa; Hubert Yamada; Alan Ryan; Richard Shelton; Mel Inouye; Andrew J. Pickles; Yanko K. Ivanov

2006-04-01T23:59:59.000Z

420

The MARTE VNIR Imaging Spectrometer Experiment: Design and Analysis  

E-Print Network [OSTI]

We report on the design, operation, and data analysis methods employed on the VNIR imaging spectrometer instrument that was part of the Mars Astrobiology Research and Technology Experiment (MARTE). The imaging spectrometer is a hyperspectral scanning pushbroom device sensitive to VNIR wavelengths from 400-1000 nm. During the MARTE project, the spectrometer was deployed to the Rio Tinto region of Spain. We analyzed subsets of 3 cores from Rio Tinto using a new band modeling technique. We found most of the MARTE drill cores to contain predominantly goethite, though spatially coherent areas of hematite were identified in Core 23. We also distinguished non Fe-bearing minerals that were subsequently analyzed by X-ray diffraction (XRD) and found to be primarily muscovite. We present drill core maps that include spectra of goethite, hematite, and non Fe-bearing minerals.

Brown, Adrian J; Dunagan, Stephen

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "imaging instrumentation radiobiology" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Two wide-angle imaging neutral-atom spectrometers (TWINS)  

SciTech Connect (OSTI)

Two Wide-angle Imaging Neutral-atom Spectrometers (TWINS) is a revolutionary new mission designed to stereoscopically image the magnetosphere in charge exchange neutral atoms for the first time. The authors propose to fly two identical TWINS instruments as a mission of opportunity on two widely-spaced high-altitude, high-inclination US Government spacecraft. Because the spacecraft are funded independently, TWINS can provide a vast quantity of high priority science observations (as identified in an ongoing new missions concept study and the Sun-Earth Connections Roadmap) at a small fraction of the cost of a dedicated mission. Because stereo observations of the near-Earth space environs will provide a particularly graphic means for visualizing the magnetosphere in action, and because of the dedication and commitment of the investigator team to the principles of carrying space science to the broader audience, TWINS will also be an outstanding tool for public education and outreach.

McComas, D.J. [Los Alamos National Lab., NM (United States)] [Los Alamos National Lab., NM (United States); Blake, B. [Aerospace Corp., CA (United States)] [Aerospace Corp., CA (United States); Burch, J. [Southwest Research Inst., San Antonio, TX (United States)] [and others] [Southwest Research Inst., San Antonio, TX (United States); and others

1998-11-01T23:59:59.000Z

422

Electronic constant current and current pulse signal generator for nuclear instrumentation testing  

DOE Patents [OSTI]

Circuitry is described for testing the ability of an intermediate range nuclear instrument to detect and measure a constant current and a periodic current pulse. The invention simulates the resistance and capacitance of the signal connection of a nuclear instrument ion chamber detector and interconnecting cable. An LED flasher/oscillator illuminates an LED at a periodic rate established by a timing capacitor and circuitry internal to the flasher/oscillator. When the LED is on, a periodic current pulse is applied to the instrument. When the LED is off, a constant current is applied. An inductor opposes battery current flow when the LED is on. 1 figures.

Brown, R.A.

1994-04-19T23:59:59.000Z

423

EVALUATION OF THE SACCHAROFLEX 2000 REFLECTANCE MEASURING INSTRUMENT FOR REFINED SUGAR COLOUR ESTIMATION AT HULETTS REFINERY  

E-Print Network [OSTI]

Due to the successful use of the Saccharoflex 2000 reflectance measurement instrument on the estimation of refined sugar colour elsewhere in the world, it was decided by Tongaat-Hulett Sugar to evaluate the instrument at the refinery in Durban. Tests were carried out on first, second, third and fourth refined sugars, the results of which showed a good correlation between the ICUMSA colour measurement and the reflectance reading obtained from the Saccharoflex 2000. The instrument offers a number of advantages, the main one being that a refined sugar colour value can be obtained in less than a minute. The refinery has therefore purchased one for process control.

M Moodley; N K Padayachee; V Govender

424

Experimental Mechanical and Fluid Mechanical Investigations of the Brass Instrument Lip-reed and the Human Vocal Folds   

E-Print Network [OSTI]

The mechanical properties of the lips are of crucial importance to the function of a brass instrument. The natural resonance modes must be able to usefully interact with the instrument air column in order to sustain ...

Newton, Michael James

2009-01-01T23:59:59.000Z

425

An analysis of navigational instruments in the Age of Exploration: 15th century to mid-17th century  

E-Print Network [OSTI]

from 27 of these shipwreck sites. These instruments provide the basis to develop a typology for archaeologists to more closely date these finds. The navigation instruments recovered from the wreck of LaBelle (1686) are discussed in detail...

Swanick, Lois Ann

2006-04-12T23:59:59.000Z

426

Final Report for The University of Texas at Arlington Optical Medical Imaging Section of Advanced Imaging Research Center  

SciTech Connect (OSTI)

The goal of this project was to create state-of-the-art optical medical imaging laboratories for the Biomedical Engineering faculty and student researchers of the University of Texas at Arlington (UTA) on the campus of the University of Texas Southwestern Medical Center (UTSW). This has been successfully achieved. These laboratories provide an unprecedented opportunity for the bioengineers (from UTA) to bring about new breakthroughs in medical imaging using optics. Specifically, three major laboratories have been successfully established and state-of-the-art scientific instruments have been placed in the labs. As a result of this grant, numerous journal and conference publications have been generated, patents for new inventions have been filed and received, and many additional grants for the continuation of the research has been received.

Khosrow Behbehani

2013-02-26T23:59:59.000Z

427

Compact low resolution spectrograph, an imaging and long slit spectrograph for robotic telescopes  

SciTech Connect (OSTI)

The COmpact LOw REsolution Spectrograph (COLORES) is a compact and lightweight (13 kg) f/8 imaging spectrograph designed for robotic telescopes, now installed and operating on the TELMA, a rapid-slewing 60 cm telescope of the BOOTES-2 observatory in Málaga (Spain). COLORES is a multi-mode instrument that enables the observer to seamlessly switch between low-dispersion spectroscopy and direct imaging modes during an observation. In this paper, we describe the instrument and its development, from the initial scientific requirements through the optical design process to final configuration with theoretical performance calculations. The mechanical and electronic design is described, methods of calibration are discussed and early laboratory and scientific results are shown.

Rabaza, O., E-mail: ovidio@ugr.es [Department of Civil Engineering, University of Granada, Severo Ochoa Str. s/n, 18071 Granada (Spain); Institute of Astrophysics of Andalucía (CSIC), Glorieta de la Astronomía s/n, 18008 Granada (Spain); Jelinek, M.; Cunniffe, R.; Ruedas-Sánchez, J. [Institute of Astrophysics of Andalucía (CSIC), Glorieta de la Astronomía s/n, 18008 Granada (Spain)] [Institute of Astrophysics of Andalucía (CSIC), Glorieta de la Astronomía s/n, 18008 Granada (Spain); Castro-Tirado, A. J. [Institute of Astrophysics of Andalucía (CSIC), Glorieta de la Astronomía s/n, 18008 Granada (Spain) [Institute of Astrophysics of Andalucía (CSIC), Glorieta de la Astronomía s/n, 18008 Granada (Spain); Department of Systems and Automatic Engineering, University of Málaga, 29071 Málaga (Spain); Zeman, J. [Astronomical Institute of the Academic of Sciences, Fricova 298, 25165 Ondrejov (Czech Republic)] [Astronomical Institute of the Academic of Sciences, Fricova 298, 25165 Ondrejov (Czech Republic); Hudec, R. [Astronomical Institute of the Academic of Sciences, Fricova 298, 25165 Ondrejov (Czech Republic) [Astronomical Institute of the Academic of Sciences, Fricova 298, 25165 Ondrejov (Czech Republic); Faculty of Electrical Engineering, Czech Technical University, Technicka 2, Praha 6 (Czech Republic); Sabau-Graziati, L. [National Institute of Aerospace Technology, Carretera de Ajalvir, 28850 Madrid (Spain)] [National Institute of Aerospace Technology, Carretera de Ajalvir, 28850 Madrid (Spain)

2013-11-15T23:59:59.000Z

428

Multispectral imaging probe  

DOE Patents [OSTI]

A multispectral imaging probe delivers a range of wavelengths of excitation light to a target and collects a range of expressed light wavelengths. The multispectral imaging probe is adapted for mobile use and use in confined spaces, and is sealed against the effects of hostile environments. The multispectral imaging probe comprises a housing that defines a sealed volume that is substantially sealed from the surrounding environment. A beam splitting device mounts within the sealed volume. Excitation light is directed to the beam splitting device, which directs the excitation light to a target. Expressed light from the target reaches the beam splitting device along a path coaxial with the path traveled by the excitation light from the beam splitting device to the target. The beam splitting device directs expressed light to a collection subsystem for delivery to a detector.

Sandison, David R. (Moriarty, NM); Platzbecker, Mark R. (Albuquerque, NM); Descour, Michael R. (Tucson, AZ); Armour, David L. (Albuquerque, NM); Craig, Marcus J. (Albuquerque, NM); Richards-Kortum, Rebecca (Austin, TX)

1999-01-01T23:59:59.000Z

429

Multispectral imaging probe  

DOE Patents [OSTI]

A multispectral imaging probe delivers a range of wavelengths of excitation light to a target and collects a range of expressed light wavelengths. The multispectral imaging probe is adapted for mobile use and use in confined spaces, and is sealed against the effects of hostile environments. The multispectral imaging probe comprises a housing that defines a sealed volume that is substantially sealed from the surrounding environment. A beam splitting device mounts within the sealed volume. Excitation light is directed to the beam splitting device, which directs the excitation light to a target. Expressed light from the target reaches the beam splitting device along a path coaxial with the path traveled by the excitation light from the beam splitting device to the target. The beam splitting device directs expressed light to a collection subsystem for delivery to a detector. 8 figs.

Sandison, D.R.; Platzbecker, M.R.; Descour, M.R.; Armour, D.L.; Craig, M.J.; Richards-Kortum, R.

1999-07-27T23:59:59.000Z

430

Variable waveband infrared imager  

DOE Patents [OSTI]

A waveband imager includes an imaging pixel that utilizes photon tunneling with a thermally actuated bimorph structure to convert infrared radiation to visible radiation. Infrared radiation passes through a transparent substrate and is absorbed by a bimorph structure formed with a pixel plate. The absorption generates heat which deflects the bimorph structure and pixel plate towards the substrate and into an evanescent electric field generated by light propagating through the substrate. Penetration of the bimorph structure and pixel plate into the evanescent electric field allows a portion of the visible wavelengths propagating through the substrate to tunnel through the substrate, bimorph structure, and/or pixel plate as visible radiation that is proportional to the intensity of the incident infrared radiation. This converted visible radiation may be superimposed over visible wavelengths passed through the imaging pixel.

Hunter, Scott R.

2013-06-11T23:59:59.000Z

431

Instrumental learning within the spinal cord: further examination of the deficit observed following noncontingent shock  

E-Print Network [OSTI]

events that cannot be controlled (noncontingent events) has a deleterious effect on instrumental learning, much like exposure to inescapable shock affects escape/avoidance learning in intact animals. Experiment 1 showed that noncontingent tailshock has...

Crown, Eric Daniel

2000-01-01T23:59:59.000Z

432

Operation of automated NDA instruments for in-line HEU accounting at Y-12  

SciTech Connect (OSTI)

Two automated nondestructive assay instruments developed at Los Alamos in support of nuclear materials accounting needs are currently operating in-line at the Y-12 Plant for recovery of highly enriched uranium. One instrument provides the HEU inventory in the secondary solvent extraction system, and the other monitors HEU concentration in the secondary intermediate evaporator. Both instruments were installed in December 1982. Operational evaluation of these instruments has been a joint effort of Y-12 and Los Alamos. This has included comparison of the solvent extraction system inventories with direct measurement performed on the dumped solution components of the solvent extraction system, as well as comparisons of concentration assay results with the external assays of samples withdrawn from the process. The function, design, and preliminary results of the operational evaluation are reported.

Russo, P.A.; Strittmatter, R.B.; Sandford, E.L.; Jeter, I.W.; McCullough, E.; Bowers, G.L.

1983-01-01T23:59:59.000Z

433

The Electric Field and Waves Instruments on the Radiation Belt Storm Probes Mission  

E-Print Network [OSTI]

The Electric Fields and Waves (EFW) Instruments on the two Radiation Belt Storm Probe (RBSP) spacecraft (recently renamed the Van Allen Probes) are designed to measure three dimensional quasi-static and low frequency ...

Wygant, J. R.

434

American Foreign Policy: A Time for a Shift in Priorities and Instruments  

E-Print Network [OSTI]

In the post 9/11 world of American Foreign Policy, where interdependence and globalization are variables that influence every aspect of world affairs, what should the priorities of the United States be and what instruments of foreign policy...

Issa, Patrick 1989-

2011-05-05T23:59:59.000Z

435

Piping inspection instrument carriage with precise and repeatable position control and location determination  

DOE Patents [OSTI]

An instrument carriage for inspection of piping comprises front and rear leg assemblies for engaging the interior of the piping and supporting and centering the carriage therein, and an instrumentation arm carried by a shaft system running from the front to rear leg assemblies. The shaft system has a screw shaft for moving the arm axially and a spline gear for moving the arm azimuthally. The arm has a pair of air cylinders that raise and lower a plate in the radial direction. On the plate are probes including an eddy current probe and an ultrasonic testing probe. The ultrasonic testing probe is capable of spinning 360[degree] about its axis. The instrument carriage uses servo motors and pressurized air cylinders for precise actuation of instrument components and precise, repeatable actuation of position control mechanisms. 8 figures.

Hapstack, M.; Talarek, T.R.; Zollinger, W.T.; Heckendorn, F.M. II; Park, L.R.

1994-02-15T23:59:59.000Z

436

Piping inspection instrument carriage with precise and repeatable position control and location determination  

DOE Patents [OSTI]

An instrument carriage for inspection of piping comprises front and rear leg assemblies for engaging the interior of the piping and supporting and centering the carriage therein, and an instrumentation arm carried by a shaft system running from the front to rear leg assemblies. The shaft system has a screw shaft for moving the arm axially and a spline gear for moving the arm azimuthally. The arm has a pair of air cylinders that raise and lower a plate in the radial direction. On the plate are probes including an eddy current probe and an ultrasonic testing probe. The ultrasonic testing probe is capable of spinning 360.degree. about its axis. The instrument carriage uses servo motors and pressurized air cylinders for precise actuation of instrument components and precise, repeatable actuation of position control mechanisms.

Hapstack, Mark (North Augusta, SC); Talarek, Ted R. (Augusta, GA); Zollinger, W. Thor (Martinez, GA); Heckendorn, II, Frank M. (Alken, SC); Park, Larry R. (North Augusta, SC)

1994-01-01T23:59:59.000Z

437

lexical database from readers -1 Behavioral Research Methods, Instruments and Computers, 36, 156-166.  

E-Print Network [OSTI]

2012 #12;lexical database from readers - 4 INTRODUCTION The history of lexicographical studies based, syllabus design and materials writing. Short history of French language lexical databases Concerninglexical database from readers - 1 Behavioral Research Methods, Instruments and Computers, 36, 156

Paris-Sud XI, Université de

438

Micro and nano mechanics of materials response during instrumented frictional sliding  

E-Print Network [OSTI]

Over the past decade, many computational studies have explored the mechanics of instrumented normal indentation. In contrast, very few studies have investigated quantitative aspects of frictional sliding contact in the ...

Bellemare, Simon C. (Simon Claude)

2006-01-01T23:59:59.000Z

439

Implementation of an ASIC for Detector Instrumentation in Nuclear Physics Applications   

E-Print Network [OSTI]

A prototype ASIC (EFT1) for silicon strip detector instrumentation has been designed and tested. The ASIC design contains the electronics necessary for preamplification, shaping, hit detection, and data readout control.The ...

McIntosh, James Alexander

1996-01-01T23:59:59.000Z

440

In Situ Energy Loss Instruments for Insulation Economy and Process Control  

E-Print Network [OSTI]

and follow changes off ambient weather conditions for indoor, outdoor, buried and downhole applications. A variation of this instrument can be placed on columns under insulation to act as control sensor for adiabatic operation....

Hauser, R. L.; McKeever, R. B.; Stull, D. P.

Note: This page contains sample records for the topic "imaging instrumentation radiobiology" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Measuring total longshore sediment transport with a LISST instrumented mini-sled.  

E-Print Network [OSTI]

A surf zone sediment transport study was conducted in Jamaica Beach, Texas, using new oceanographic equipment. A mini-sled was constructed and outfitted with an instrument package that consisted of two velocimeters, one current profiler, three OBS...

Huchzermeyer, Erick Karl

2006-04-12T23:59:59.000Z

442

Development of a Software SecurityAssessment Instrument to Reduce Software SecurityRisk  

E-Print Network [OSTI]

system, has vulnerabilities. (SAT) for use in the software development and maintenance life cycle throughout the sofhvare development and maintenance life cycle. The. security assessment instrument includes security assessment for use in the software development and maintenance life cycle. Currently

Bishop, Matt

443

Identification, Model Updating, and Response Prediction of an Instrumented 15-Story Steel-Frame Building  

E-Print Network [OSTI]

A. , 1998. Ductile Design of Steel Structure, McGraw Hill,monitoring of the steel-frame UCLA Factor Building,an Instrumented 15-Story Steel-Frame Building Derek Skolnik,

Skolnik, Derek; Lei, Ying; Yu, Eunjong; Wallace, J W

2006-01-01T23:59:59.000Z

444

SCUBA-2 instrument: an application of large-format superconducting bolometer arrays for submillimetre astronomy   

E-Print Network [OSTI]

This thesis concerns technical aspects related to the design and operation of the submillimetre common-user bolometer array 2 (SCUBA-2) instrument, a new wide-field camera for submillimetre astronomy currently undergoing ...

Hollister, Matthew Ian

445

X-ray optics metrology limited by random noise, instrumental drifts, and systematic errors  

E-Print Network [OSTI]

X-ray optics metrology limited by random noise, instrumentalUSA Center for X-ray Optics, Lawrence Berkeley Nationaland reflecting x-ray optics suitable for micro- and nano-

Yashchuk, Valeriy V.

2010-01-01T23:59:59.000Z

446

Fast facility spent-fuel and waste assay instrument. [Fluorinel Dissolution and Fuel Storage (FAST) Facility  

SciTech Connect (OSTI)

A delayed-neutron assay instrument was installed in the Fluorinel Dissolution and Fuel Storage Facility at Idaho National Engineering Laboratory. The dual-assay instrument is designed to measure both spent fuel and waste solids that are produced from fuel processing. A set of waste standards, fabricated by Los Alamos using uranium supplied by Exxon Nuclear Idaho Company, was used to calibrate the small-sample assay region of the instrument. Performance testing was completed before installation of the instrument to determine the effects of uranium enrichment, hydrogenous materials, and neutron poisons on assays. The unit was designed to measure high-enriched uranium samples in the presence of large neutron backgrounds. Measurements indicate that the system can assay low-enriched uranium samples with moderate backgrounds if calibrated with proper standards.

Eccleston, G.W.; Johnson, S.S.; Menlove, H.O.; Van Lyssel, T.; Black, D.; Carlson, B.; Decker, L.; Echo, M.W.

1983-01-01T23:59:59.000Z

447

In Situ, Airborne Instrumentation: Addressing and Solving Measurement Problems in Ice Clouds  

E-Print Network [OSTI]

A meeting of 31 international experts on in situ measurements from aircraft was held to identify unresolved questions concerning ice formation and evolution in ice clouds, assess the current state of instrumentation that ...

Cziczo, Daniel James

448

PLC and DTAM Software Programs for Pumping Instrumentation and Control Skid M  

SciTech Connect (OSTI)

This document describes the software programs for the Programmable Logic Controller and the Data Table Access Module for Pumping Instrumentation and Control skid ''M''. The Appendices contains copies of the printouts of these software programs.

KOCH, M.R.

2000-02-14T23:59:59.000Z

449

PLC/DTAM Software Programs for Pumping Instrumentation and Control Skid L  

SciTech Connect (OSTI)

This document describes the software programs for the Programmable Logic Controller and the Data Table Access Module for Pumping Instrumentation and Control skid ''L''. The Appendices contains copies of the printouts of these software programs.

KOCH, M.R.

2000-01-03T23:59:59.000Z

450

PLC and DTAM Software Programs for Pumping Instrumentation and Control Skid P  

SciTech Connect (OSTI)

This document describe the software programs for the Programmable Logic Controller and the Datable Access Module for Pumping Instrumentation and Control skid ''P''. The Appendices contains copies of the printouts of these software programs.

KOCH, M.R.

2000-05-11T23:59:59.000Z

451

Instrumented tools and objects : design, algorithms, and applications to assembly tasks  

E-Print Network [OSTI]

We developed an instrumented tool system comprised of wireless nodes and sensor systems to facilitate distributed robotic assembly tasks. This robotic system was deployed on two separate robotic assembly scenarios: one ...

Faulkner, Matthew N

2011-01-01T23:59:59.000Z

452

Neutron monitoring systems including gamma thermometers and methods of calibrating nuclear instruments using gamma thermometers  

DOE Patents [OSTI]

A method of calibrating a nuclear instrument using a gamma thermometer may include: measuring, in the instrument, local neutron flux; generating, from the instrument, a first signal proportional to the neutron flux; measuring, in the gamma thermometer, local gamma flux; generating, from the gamma thermometer, a second signal proportional to the gamma flux; compensating the second signal; and calibrating a gain of the instrument based on the compensated second signal. Compensating the second signal may include: calculating selected yield fractions for specific groups of delayed gamma sources; calculating time constants for the specific groups; calculating a third signal that corresponds to delayed local gamma flux based on the selected yield fractions and time constants; and calculating the compensated second signal by subtracting the third signal from the second signal. The specific groups may have decay time constants greater than 5.times.10-1 seconds and less than 5.times.105 seconds.

Moen, Stephan Craig; Meyers, Craig Glenn; Petzen, John Alexander; Foard, Adam Muhling

2012-08-07T23:59:59.000Z

453

The First Extrasolar Planet Discovered with a New Generation High Throughput Doppler Instrument  

E-Print Network [OSTI]

), using the Exoplanet Tracker (ET), a new generation Doppler instrument. The planet orbits HD 102195, a young star with solar metallicity that may be part of the local association. The planet imparts radial

Complutense de Madrid, Universidad

454

Behavior Research Methods, Instruments, & Computers 2001, 33 (4), 517-523  

E-Print Network [OSTI]

Behavior Research Methods, Instruments, & Computers 2001, 33 (4), 517-523 Across the social by a preprogrammedpager or wrist watch.Around the same time,William Brewer (1988) described a similar sampling technique

Pillow, Jonathan

455

E-Print Network 3.0 - als instrument der Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

and Information Sciences 5 B. Sc. Computing in Science -Modulbeschreibung Modul-Kennung PHY-AP-CiS (Die Kennung kann sich noch ndern) Summary: Instrumente der Physik. II....

456

The investigation of spices by use of instrumental neutron activation analysis  

E-Print Network [OSTI]

contaminants. For this research, instrumental neutron-activation analysis (INAA) was used to determine the activities of U-235 fission products in common spices. Using this information, the concentrations of natural uranium in these spices and the doses...

Wise, Jatara Rob

2008-10-10T23:59:59.000Z

457

ECE 331 -Biomedical Instrumentation Department of Electrical & Computer Engineering, UBC Cardiac Measurements  

E-Print Network [OSTI]

ECE 331 - Biomedical Instrumentation Department of Electrical & Computer Engineering, UBC Lab #7 Repeatability for each person. Is this a very meaningful value? Why or why not? #12;ECE 331 - Biomedical

Pulfrey, David L.

458

Process reengineering for the product development process at an analytical instrument manufacturer  

E-Print Network [OSTI]

In an analytical instrument manufacturing company, the new product development process was analyzed with the objective of reducing time to market, to full scale production of new products and to improve project management ...

Tandon, Shubhang

2014-01-01T23:59:59.000Z

459

ORNL instrumentation performance for Slab Core Test Facility (SCTF)-Core I Reflood Test Facility  

SciTech Connect (OSTI)

Instrumentation was developed for making measurements in experimental refill-reflood test facilities. These unique instrumentation systems were designed to survive the severe environmental conditions that exist during a simulated pressurized water reactor loss-of-coolant accident (LOCA). Measurement of in-vessel fluid phenomena such as two-phase flow velocity and void fraction and film thickness and film velocity are required for better understanding of reactor behavior during LOCAs. The Advanced Instrumentation for Reflood Studies (AIRS) Program fabricated and delivered instrumentation systems and data reduction software algorithms that allowed the above measurements to be made. Data produced by AIRS sensors during three experimental runs in the Japanese Slab Core Test Facility are presented. Although many of the sensors failed before any useful data could be obtained, the remaining probes gave encouraging and useful results. These results are the first of their kind produced during simulated refill-reflood stage of a LOCA near actual thermohydrodynamic conditions.

Hardy, J E; Hess, R A; Hylton, J O

1983-11-01T23:59:59.000Z

460

Considerations of driver preferences and performance for selection of electronic automobile instrumentation  

E-Print Network [OSTI]

CONSIDERATIONS OF DRIVER PREFERENCES AND PERFORMANCE FOR SELECTION OF ELECTRONIC AUTOMOBILE INSTRUMENTATION A Thesis by RAYMOND SCOTT HARWOOD Submitted to the Graduate College of Texas A&M University in partial fulfillment of the requirements... for the degree of MASTER OF SCIENCE May 1988 Major Subject: Industrial Engineering CONSIDERATIONS OF DRIVER PREFERENCES AND PERFORMANCE FOR SELECTION OF ELECTRONIC AUTOMOBILE INSTRUMENTATION A Thesis by RAYMOND SCOTT HARWOOD Approved as to style...

Harwood, Raymond Scott

1988-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "imaging instrumentation radiobiology" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

International Energy Agency instrumented facilities survey for solar assisted low energy dwellings  

SciTech Connect (OSTI)

Compiled are surveys outlining the instrumentation of 38 active and passive solar projects in 9 countries (Denmark, Italy, Japan, Netherlands, Sweden, Switzerland, United Kingdom, United States, and West Germany). After the surveys themselves are presented, the data are rearranged to compare answers from similar survey questions for each of the projects. These questions address building, solar system and instrumentation descriptions and meteorological, solar system and building system instrumentatation capabilities. (LEW)

none,

1982-02-01T23:59:59.000Z

462

Proceedings of the 1981 symposium on instrumentation and control for fossil-energy processes  

SciTech Connect (OSTI)

The 1981 symposium on instrumentation and control for fossil-energy processes was held June 8-10, 1981, at the Sheraton-Palace Hotel, San Francisco, California. It was sponsored by the US Department of Energy; Office of Fossil Energy; Argonne National Laboratory; and the Society for Control and Instrumentation of Energy Processes. Sixty-seven articles from the proceedings have been entered individually into EDB and ERA; thirteen articles had been entered previously from other sources. (LTN)

Not Available

1982-01-01T23:59:59.000Z

463

IFP V4.0:a polar-reformatting image formation processor for synthetic aperture radar.  

SciTech Connect (OSTI)

IFP V4.0 is the fourth generation of an extraordinarily powerful and flexible image formation processor for spotlight mode synthetic aperture radar. It has been successfully utilized in processing phase histories from numerous radars and has been instrumental in the development of many new capabilities for spotlight mode SAR. This document provides a brief history of the development of IFP, a full exposition of the signal processing steps involved, and a short user's manual for the software implementing this latest iteration.

Eichel, Paul H.

2005-09-01T23:59:59.000Z

464

Imaging ion outflow in the high-latitude magnetosphere using low-energy neutral atoms  

SciTech Connect (OSTI)

The measurement of neutral atom fluxes generated by charge exchange with the Earth's geocorona has recently been shown to provide the capability to image the magnetosphere. The authors investigate neutral oxygen fluxes produced by charge exchange from the cusp/cleft ion fountain population. Using an empirical cusp/cleft ion fountain model, an empirical variation of the geocoronal neutral hydrogen density with distance, and typical values for charge-exchange cross sections, line-of-sight integrations are performed to calculate the neutral oxygen flux at arbitrary locations in space. The resulting images are evaluated for a set of orbital positions of the proposed HI-LITE small explorer spacecraft. The resulting neutral oxygen fluxes are high enough for imaging with a low-energy neutral atom imaging instrument (ILENA) onboard the spacecraft.

Hesse, M.; Smith, M.F.; Herrero, F. (NASA, Greenbelt, MD (United States). Goddard Space Flight Center); Ghielmetti, A.G.; Shelley, E.G. (Lockheed Palo Alto Research Lab., CA (United States)); Wurz, P.; Bochsler, P. (Univ. of Bern (Switzerland)); Gallagher, D.L.; Moore, T.E. (NASA, Huntsville, AL (United States). Marshall Space Flight Center); Stephen, T.S. (Univ. of Denver, CO (United States))

1993-12-01T23:59:59.000Z

465

Direct imaging with highly diluted apertures. I. Field of view limitations  

E-Print Network [OSTI]

Future optical interferometric instrumentation mainly relies on the availability of an efficient cophasing system: once available, what has so far postponed the relevance of direct imaging with an interferometer will vanish. This paper focuses on the actual limits of snapshot imaging, inherent to the use of a sparse aperture: the number of telescopes and the geometry of the array impose the maximum extent of the field of view and the complexity of the sources. A second limitation may arise from the beam combination scheme. Comparing already available solutions, we show that the so called hypertelescope mode (or densified pupil) is ideal. By adjusting the direct imaging field of view to the useful field of view offered by the array, the hypertelescope makes an optimal use of the collected photons. It optimizes signal to noise ratio, drastically improves the luminosity of images and makes the interferometer compatible with coronagraphy, without inducing any loss of useful field of view.

O. Lardiere; F. Martinache; F. Patru

2006-12-04T23:59:59.000Z

466

Characteristic Count Rate Profiles for a Rotating Modulator Gamma-Ray Imager  

E-Print Network [OSTI]

Rotating modulation is a technique for indirect imaging in the hard x-ray and soft gamma-ray energy bands, which may offer an advantage over coded aperture imaging at high energies. A rotating modulator (RM) consists of a single mask of co-planar parallel slats typically spaced equidistance apart, suspended above an array of circular non-imaging detectors. The mask rotates, temporally modulating the transmitted image of the object scene. The measured count rate profiles of each detector are folded modulo the mask rotational period, and the object scene is reconstructed using pre-determined characteristic modulation profiles. The use of Monte Carlo simulation to derive the characteristic count rate profiles is accurate but computationally expensive; an analytic approach is preferred for its speed of computation. We present both the standard and a new advanced characteristic formula describing the modulation pattern of the RM; the latter is a more robust description of the instrument response developed as part ...

Budden, Brent S; Case, Gary L; Cherry, Michael L

2011-01-01T23:59:59.000Z

467

Reprinted from the Journal of Scientific Instruments, VOL. 41, pp. 321323, MAY 1964 ` A water wave recording instrument for use in hydraulic models  

E-Print Network [OSTI]

recording instrument for use in hydraulic models J. B. MOORET Department of Electrical Engineering for recording water waves in hydraulic models. 1. Introduction The measurement of water-wave magnitudes and the record. ing of waveforms is often carried out in hydraulic laboratories. If, for example, the most

Moore, John Barratt

468

2010 National Instruments. All rights reserved. Visit ni.com/legal. For patents see ni.com/patents. National Instruments LabVIEW Boot Camp at  

E-Print Network [OSTI]

.com/patents. National Instruments LabVIEW Boot Camp at Arizona State University June 16 - 19, 2014 8:00 AM - 5:00 PM Each day Memorial Union - Cochise & Union Stage Register today to attend our upcoming NI LabVIEW Boot

Reisslein, Martin

469

High-resolution retinal imaging using adaptive optics and Fourier-domain optical coherence tomography  

DOE Patents [OSTI]

This invention permits retinal images to be acquired at high speed and with unprecedented resolution in three dimensions (4.times.4.times.6 .mu.m). The instrument achieves high lateral resolution by using adaptive optics to correct optical aberrations of the human eye in real time. High axial resolution and high speed are made possible by the use of Fourier-domain optical coherence tomography. Using this system, we have demonstrated the ability to image microscopic blood vessels and the cone photoreceptor mosaic.

Olivier, Scot S. (Livermore, CA); Werner, John S. (Davis, CA); Zawadzki, Robert J. (Sacramento, CA); Laut, Sophie P. (Pasedena, CA); Jones, Steven M. (Livermore, CA)

2010-09-07T23:59:59.000Z

470

A probable giant planet imaged in the Beta Pictoris disk  

E-Print Network [OSTI]

Since the discovery of its dusty disk in 1984, Beta Pictoris has become the prototype of young early-type planetary systems, and there are now various indications that a massive Jovian planet is orbiting the star at ~ 10 AU. However, no planets have been detected around this star so far. Our goal was to investigate the close environment of Beta Pic, searching for planetary companion(s). Deep adaptive-optics L'-band images of Beta Pic were recorded using the NaCo instrument at the Very Large Telescope. A faint point-like signal is detected at a projected distance of ~ 8 AU from the star, within the North-East side of the dust disk. Various tests were made to rule out with a good confidence level possible instrumental or atmospheric artifacts. The probability of a foreground or background contaminant is extremely low, based in addition on the analysis of previous deep Hubble Space Telescope images. The object L'=11.2 apparent magnitude would indicate a typical temperature of ~1500 K and a mass of ~ 8 Jovian masses. If confirmed, it could explain the main morphological and dynamical peculiarities of the Beta Pic system. The present detection is unique among A-stars by the proximity of the resolved planet to its parent star. Its closeness and location inside the Beta Pic disk suggest a formation process by core accretion or disk instabilities rather than a binary-like formation process.

A. -M. Lagrange; D. Gratadour; G. Chauvin; T. Fusco; D. Ehrenreich; D. Mouillet; G. Rousset; D. Rouan; F. Allard; E. Gendron; J. Charton; L. Mugnier; P. Rabou; J. Montri; F. Lacombe

2008-11-21T23:59:59.000Z

471

1st Advanced Marine Renewable Energy Instrumentation Experts Workshop: April 5-7, 2011  

SciTech Connect (OSTI)

The U.S. marine energy industry is actively pursuing development of offshore wind and marine hydrokinetic (MHK) energy systems. Experience in the wind energy sector demonstrates that new technology development requires thorough measurement and characterization of the environmental conditions prevalent at installation sites and of technology operating in the field. Presently, there are no turn-key instrumentation system solutions that meet the measurement needs of the marine energy industry. The 1st Advanced Marine Renewable Energy Instrumentation Experts Workshop brought together technical experts from government laboratories, academia, and industry representatives from marine energy, wind, offshore oil and gas, and instrumentation developers to present and discuss the instrumentation needs of the marine energy industry. The goals of the meeting were to: (1) Share the latest relevant knowledge among technical experts; (2) Review relevant state-of-the-art field measurement technologies and methods; (3) Review lessons learned from recent field deployments; (4) Identify synergies across different industries; (5) Identify gaps between existing and needed instrumentation capabilities; (6) Understand who are the leading experts; (7) Provide a forum where stakeholders from the marine energy industry could provide substantive input in the development of new marine energy field deployable instrumentation packages.

Not Available

2011-10-01T23:59:59.000Z

472

Graphical Methods for Quantifying Macromolecules through Bright Field Imaging  

SciTech Connect (OSTI)

Bright ?eld imaging of biological samples stained with antibodies and/or special stains provides a rapid protocol for visualizing various macromolecules. However, this method of sample staining and imaging is rarely employed for direct quantitative analysis due to variations in sample fixations, ambiguities introduced by color composition, and the limited dynamic range of imaging instruments. We demonstrate that, through the decomposition of color signals, staining can be scored on a cell-by-cell basis. We have applied our method to Flbroblasts grown from histologically normal breast tissue biopsies obtained from two distinct populations. Initially, nuclear regions are segmented through conversion of color images into gray scale, and detection of dark elliptic features. Subsequently, the strength of staining is quanti?ed by a color decomposition model that is optimized by a graph cut algorithm. In rare cases where nuclear signal is significantly altered as a result of samplepreparation, nuclear segmentation can be validated and corrected. Finally, segmented stained patterns are associated with each nuclear region following region-based tessellation. Compared to classical non-negative matrix factorization, proposed method (i) improves color decomposition, (ii) has a better noise immunity, (iii) is more invariant to initial conditions, and (iv) has a superior computing performance

Chang, Hang; DeFilippis, Rosa Anna; Tlsty, Thea D.; Parvin, Bahram

2008-08-14T23:59:59.000Z

473

\\NeuroImage" Informatics  

E-Print Network [OSTI]

International Neuroimaging Consortium Introduction Author cocitation analysis describes a scienti#12;c #12;eld on data collected by the Institute of Scien- ti#12;c Information among a limited set of key au- thors within a #12;eld. Here we work on data from a single journal (the journal \\NeuroImage") down- loaded from

Nielsen, Finn Ã?rup

474

EBSD Images Theoretical Background  

E-Print Network [OSTI]

Motivation EBSD Images Theoretical Background Defects in the Weld Grain Growth Low Speed Welding High Speed Welding Conclusion Heat-Affected Zone Observations Welding Experiments The low density in the transportation industries. Reproducibility and the low cost make welding a major large scale assembly process

Candea, George

475

Image Charge Differential  

E-Print Network [OSTI]

Image Charge Differential Amplifier FT 0 Crude Oil Time (s) 543210 Frequency (kHz) m/z m q B f Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) uses the frequency of cyclotron motion of the ions in a static magnetic field to determine the mass-to-charge ratio, which is then used

Weston, Ken

476

Fundamentals of Image Processing  

E-Print Network [OSTI]

Fourier transform Log power spectrum #12;Review - The Convolution Theorem · The Fourier transform components · Fourier (1807): Periodic functions could be represented as a weighted sum of sines and cosines Image courtesy of Technology Review #12;Review - Fourier Transform We want to understand

Erdem, Erkut

477

Time-Encoded Imagers.  

SciTech Connect (OSTI)

This report provides a short overview of the DNN R&D funded project, Time-Encoded Imagers. The project began in FY11 and concluded in FY14. The Project Description below provides the overall motivation and objectives for the project as well as a summary of programmatic direction. It is followed by a short description of each task and the resulting deliverables.

Marleau, Peter; Brubaker, Erik

2014-11-01T23:59:59.000Z

478

Image Reconstruction for Prostate Specific Nuclear Medicine imagers  

SciTech Connect (OSTI)

There is increasing interest in the design and construction of nuclear medicine detectors for dedicated prostate imaging. These include detectors designed for imaging the biodistribution of radiopharmaceuticals labeled with single gamma as well as positron-emitting radionuclides. New detectors and acquisition geometries present challenges and opportunities for image reconstruction. In this contribution various strategies for image reconstruction for these special purpose imagers are reviewed. Iterative statistical algorithms provide a framework for reconstructing prostate images from a wide variety of detectors and acquisition geometries for PET and SPECT. The key to their success is modeling the physics of photon transport and data acquisition and the Poisson statistics of nuclear decay. Analytic image reconstruction methods can be fast and are useful for favorable acquisition geometries. Future perspectives on algorithm development and data analysis for prostate imaging are presented.

Mark Smith

2007-01-11T23:59:59.000Z

479

Devices, systems, and methods for imaging  

DOE Patents [OSTI]

Certain exemplary embodiments comprise a system, which can comprise an imaging plate. The imaging plate can be exposable by an x-ray source. The imaging plate can be configured to be used in digital radiographic imaging. The imaging plate can comprise a phosphor-based image storage device configured to convert an image stored therein into light.

Appleby, David (North Garden, VA); Fraser, Iain (Ruckersville, VA); Watson, Scott (Jemez Springs, NM)

2008-04-15T23:59:59.000Z

480

Instrument Science Report Title: Focus monitoring and recommendation for secondary mirror move  

E-Print Network [OSTI]

optimal position in order to prevent signi cant image degradation in the UV. This criterion is indeed adequate for WFPC2, and it appears that some measurable degradation of the FOC images at the shortest

Sirianni, Marco

Note: This page contains sample records for the topic "imaging instrumentation radiobiology" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Development of Advanced Optics and High Resolution Instrumentation for Mass Spectrometry Based Proteomics  

E-Print Network [OSTI]

Imaging mass spectrometry (MS) analysis allows scientists the ability to obtain spatial and chemical information of analytes on a wide variety of surfaces. The ability to image biological analytes is an important tool in many areas of life science...

Sherrod, Stacy D.

2010-01-14T23:59:59.000Z

482

Efficient MR image reconstruction for compressed MR imaging Junzhou Huang  

E-Print Network [OSTI]

to be very powerful for the MR image reconstruction. First, we decompose the original problem into L1 and TV.V. All rights reserved. 1. Introduction Magnetic Resonance (MR) imaging has been widely used in medical. Computation became the bottleneck that prevented this good model (1) from being used in practical MR image

Huang, Junzhou

483

Efficient MR Image Reconstruction for Compressed MR Imaging  

E-Print Network [OSTI]

demonstrate the superior performance of the proposed algorithm for com- pressed MR image reconstruction. 1 [1][2] show that it is possi- ble to accurately reconstruct the Magnetic Resonance (MR) images from for real MR images. Computation became the bottleneck that prevented this good model (1) from being used

Huang, Junzhou

484

Image Utility Assessment and a Relationship with Image Quality Assessment  

E-Print Network [OSTI]

Image Utility Assessment and a Relationship with Image Quality Assessment David M. Rouse , Romuald information to humans, and this paper investigates the utility assessment task, where human observers evaluate the usefulness of a natural image as a surrogate for a reference. Current QA algorithms implicitly assess utility

Hemami, Sheila S.

485

Instrumentation and Controls Division progress report for the period July 1, 1986 to June 30, 1988  

SciTech Connect (OSTI)

The Instrumentation and Controls (IandC) Division of Oak Ridge National Laboratory (ORNL) performs basic and applied instrumentation and controls research, development and design engineering, specialized instrument design and fabrication, and maintenance services for instruments, electronics, and computers. The IandC Division is one of the largest RandD organizations of its type among government laboratories, and it exists as the result of an organizational strategy to integrate ORNL's instrumentation and controls-related disciplines into one dedicated functional organization to increase the Laboratory's expertise and capabilities in these rapidly expanding, innovative areas of technology. The Division participates in the programs and projects of ORNL by applying its expertise and capabilities in concert with other divisions to perform basic research and mission-oriented technology development. Many of the Division's RandD tasks that are a part of a larger ORNL program are of sufficient scope that the IandC effort constitutes a separate program element with direct funding and management responsibility within the Division. The activities of IandC include performance of an RandD task in IandC facilities, the participation of from one of many IandC engineers and scientists in a multidisciplinary team working in a specific research area or development project, design and fabrication of a special instrument or instrumentation system, or a few hours of maintenance service. In its support and maintenance work, the role of the IandC Division is to provide a level of expertise appropriate to complete a job successfully at minimum overall cost and time schedule---a role which involves IandC in almost all ORNL activities.

Klobe, L.E. (ed.)

1988-12-01T23:59:59.000Z

486

Comprehensive Study of Image Restoration Algorithms.  

E-Print Network [OSTI]

??Abstract Comprehensive Study of Image Restoration Algorithms By Lize Zong Master of Science in Electrical Engineering Image restoration is an important part of digital image-processing.… (more)

Zong, Lize

2015-01-01T23:59:59.000Z

487

Unsupervised Image Ranking Eva Hrster  

E-Print Network [OSTI]

these are the most interesting and relevant shots. For instance, if there are many images of the Golden Gate Bridge

Weinberger, Kilian

488

Gemini Planet Imager: Preliminary Design Report  

SciTech Connect (OSTI)

For the first time in history, direct and indirect detection techniques have enabled the exploration of the environments of nearby stars on scales comparable to the size of our solar system. Precision Doppler measurements have led to the discovery of the first extrasolar planets, while high-contrast imaging has revealed new classes of objects including dusty circumstellar debris disks and brown dwarfs. The ability to recover spectrophotometry for a handful of transiting exoplanets through secondary-eclipse measurements has allowed us to begin to study exoplanets as individual entities rather than points on a mass/semi-major-axis diagram and led to new models of planetary atmospheres and interiors, even though such measurements are only available at low SNR and for a handful of planets that are automatically those most modified by their parent star. These discoveries have galvanized public interest in science and technology and have led to profound new insights into the formation and evolution of planetary systems, and they have set the stage for the next steps--direct detection and characterization of extrasolar Jovian planets with instruments such as the Gemini Planet Imager (GPI). As discussed in Volume 1, the ability to directly detect Jovian planets opens up new regions of extrasolar planet phase space that in turn will inform our understanding of the processes through which these systems form, while near-IR spectra will advance our understanding of planetary physics. Studies of circumstellar debris disks using GPI's polarimetric mode will trace the presence of otherwise-invisible low-mass planets and measure the build-up and destruction of planetesimals. To accomplish the science mission of GPI will require a dedicated instrument capable of achieving contrast of 10{sup -7} or more. This is vastly better than that delivered by existing astronomical AO systems. Currently achievable contrast, about 10{sup -5} at separations of 1 arc second or larger, is completely limited by quasi-static wave front errors, so that contrast does not improve with integration times longer than about 1 minute. Using the rotation of the Earth to distinguish companions from artifacts or multiwavelength imaging improves this somewhat, but GPI will still need to surpass the performance of existing systems by one to two orders of magnitude--an improvement comparable to the transition from photographic plates to CCDs. This may sound daunting, but other areas of optical science have achieved similar breakthroughs, for example, the transition to nanometer-quality optics for extreme ultraviolet lithography, the development of MEMS wave front control devices, and the ultra-high contrast demonstrated by JPL's High Contrast Imaging Test-bed. In astronomy, the Sloan Digital Sky Survey, long baseline radio interferometry, and multi-object spectrographs have led to improvements of similar or greater order of magnitude. GPI will be the first project to apply these revolutionary techniques to ground-based astronomy, with a systems engineering approach that studies the impact of every design decision on the key metric--final detectable planet contrast.

Macintosh, B

2007-05-10T23:59:59.000Z

489

6, 19532001, 2006 Imaging gravity  

E-Print Network [OSTI]

ACPD 6, 1953­2001, 2006 Imaging gravity waves in lower stratospheric AMSU-A radiances S. D under a Creative Commons License. Atmospheric Chemistry and Physics Discussions Imaging gravity waves.eckermann@nrl.navy.mil) 1953 #12;ACPD 6, 1953­2001, 2006 Imaging gravity waves in lower stratospheric AMSU-A radiances S. D

Boyer, Edmond

490

Fourier Analysis of Ghost Imaging  

E-Print Network [OSTI]

Fourier analysis of ghost imaging (FAGI) is proposed in this paper to analyze the properties of ghost imaging with thermal light sources. This new theory is compatible with the general correlation theory of intensity fluctuation and could explain some amazed phenomena. Furthermore we design a series of experiments to verify the new theory and investigate the inherent properties of ghost imaging.

Honglin Liu; Jing Cheng; Yanfeng Bai; Shensheng Han

2006-09-28T23:59:59.000Z

491

Automated Very Low Magnification Imaging  

E-Print Network [OSTI]

of the entire available imaging area on the grid. The VLM image can then be used as a reference map of Illinois at Urbana- Champaign, Urbana, IL 61801. A typical TEM specimen grid provides approximately a 2x2 mm area that is available for imaging. In order to identify and locate suitable targets on the grid

492

DEVELOPMENT OF AN ON-LINE, REAL-TIME ALPHA RADIATION MEASURING INSTRUMENT FOR LIQUID STREAMS  

SciTech Connect (OSTI)

Thermo Power Corporation has proven the technical viability of an on-line, real-time alpha radionuclide instrument for aqueous sample analysis through laboratory and initial field tests of the instrument. The instrument has been shown to be isotonically sensitive to extremely low (ten parts per trillion, or femto Curies per liter) levels of a broad range of radioisotopes. Performance enhancement and other scaling data obtained during the course of this investigation have shown that on-line, real-time operation is possible, with a sub 30-minute response time analyzing 20 ppb (30 pCi/1) natural uranium. Now that these initial field tests in Oak Ridge, Tennessee have been successfully completed, Thermo Power plans to conduct comprehensive field tests of the instrument. The purpose of these endurance tests will be to determine the endurance characteristics of the Thermo Alpha Monitor for Water when it is used by non-Thermo Power personnel in a series of one or more extended field tests. Such endurance testing is the vital next step towards the commercialization of the Alpha Monitor. Subsequently, it will be possible to provide the DOE with an instrument that has the capability of obtaining rapid feedback about the concentrations of alpha-emitting isotope contamination in effluent water streams (Subsurface Contaminants Focus Area). It will also be useful for process control of remediation and D and D operations such as monitoring scrubber/rinse water radioactivity levels (Mixed Waste, Plutonium and D and D Focus Areas).

Unknown

1999-06-16T23:59:59.000Z

493

Status Report on Efforts to Enhance Instrumentation to Support Advanced Test Reactor Irradiations  

SciTech Connect (OSTI)

The Department of Energy (DOE) designated the Advanced Test Reactor (ATR) as a National Scientific User Facility (NSUF) in April 2007 to support U.S. leadership in nuclear science and technology. By attracting new research users - universities, laboratories, and industry - the ATR NSUF facilitates basic and applied nuclear research and development, further advancing the nation's energy security needs. A key component of the ATR NSUF effort is to prove new in-pile instrumentation techniques that are capable of providing real-time measurements of key parameters during irradiation. To address this need, an assessment of instrumentation available and under-development at other test reactors was completed. Based on this review, recommendations were made with respect to what instrumentation is needed at the ATR; and a strategy was developed for obtaining these sensors. In 2009, a report was issued documenting this program’s strategy and initial progress toward accomplishing program objectives. In 2009, a report was issued documenting this instrumentation development strategy and initial progress toward accomplishing instrumentation development program objectives. This document reports progress toward implementing this strategy in 2010.

J. L. Rempe; D. L. Knudson; J. E. Daw

2011-03-01T23:59:59.000Z

494

Assessment of instrumentation needs for advanced coal power plant applications: Final report  

SciTech Connect (OSTI)

The purpose of this study was to identify contaminants, identify instrumentation needs, assess available instrumentation and identify instruments that should be developed for controlling and monitoring gas streams encountered in the following power plants: Integrated Gasification Combined Cycle, Pressurized Fluidized Bed Combustion, and Gasification Molten Carbonate Fuel Cell. Emphasis was placed on hot gas cleanup system gas stream analysis, and included process control, research and environmental monitoring needs. Commercial process analyzers, typical of those currently used for process control purposes, were reviewed for the purpose of indicating commercial status. No instrument selection guidelines were found which were capable of replacing user interaction with the process analyzer vendors. This study leads to the following conclusions: available process analyzers for coal-derived gas cleanup applications satisfy current power system process control and regulatory requirements, but they are troublesome to maintain; commercial gas conditioning systems and in situ analyzers continue to be unavailable for hot gas cleanup applications; many research-oriented gas stream characterization and toxicity assessment needs can not be met by commercially available process analyzers; and greater emphasis should be placed on instrumentation and control system planning for future power plant applications. Analyzers for specific compounds are not recommended other than those needed for current process control purposes. Instead, some generally useful on-line laser-based and inductively coupled plasma methods are recommended for further development because of their potential for use in present hot gas cleanup research and future optimization, component protection and regulation compliance activities. 48 refs., 21 figs., 26 tabs.

Nelson, E.T.; Fischer, W.H.; Lipka, J.V.; Rutkowski, M.D.; Zaharchuk, R.

1987-10-01T23:59:59.000Z

495

ANSI and IEC standards for, and evaluation of, radiation detection instrumentation  

SciTech Connect (OSTI)

During the last quarter of 2002, an effort was started to develop performance requirements for radiation instrumentation used for the detection of illicit trafficking of radioactive material. Coordinated by the US National Institute of Science and Technology (NIST), a team was formed to establish writing committees for the development of these requirements as American National Standards Institute (ANSI) standards. The core of the new area was developed as ANSI N42, Homeland Security Instruments. A series of standards were developed followed by testing and evaluation (T&E) protocols that would be used for specific testing. Four US National Laboratories provided T&E support and work commenced to test instruments provided by manufacturers at no cost. During this time, discussions began regarding the formation of a new work group within the International Electrotechnical Commission (IEC). This new work group would be located within technical committee (TC) 45 which addresses nuclear instrumentation. This new work group, 15B, also began developing international standards to address the same instrument types. Following development of ANSI standards, the testing and evaluation process began, running for two distinct rounds. The results of the work was consolidated by NIST and released back to individual companies as well as the user community in a controlled manner. This document will provide details regarding the standards and their basis and status, as well as some information regarding the T&E process used in the USA.

Chiaro Jr, Peter John [ORNL] [ORNL

2008-01-01T23:59:59.000Z

496

A novel instrument for quantitative nanoanalytics involving complementary X-ray methodologies  

SciTech Connect (OSTI)

A novel ultra-high vacuum instrument for X-ray reflectometry and spectrometry-related techniques for nanoanalytics by means of synchrotron radiation has been constructed and commissioned. This versatile instrument was developed by the Physikalisch-Technische Bundesanstalt, Germany's national metrology institute, and includes a 9-axis manipulator that allows for an independent alignment of the samples with respect to all degrees of freedom. In addition, a rotational and translational movement of several photodiodes as well as a translational movement of an aperture system in and out of the beam is provided. Thus, the new instrument enables various analytical techniques based on energy dispersive X-ray detectors such as reference-free X-ray fluorescence analysis (XRF), total-reflection XRF, grazing-incidence XRF in addition to optional X-ray reflectometry measurements or polarization-dependent X-ray absorption fine structure analyses. With this instrument samples having a size of up to 100 mm Multiplication-Sign 100 mm can be analyzed with respect to their mass deposition, elemental or spatial composition, or the species in order to probe surface contamination, layer composition and thickness, the depth profile of matrix elements or implants, the species of nanolayers, nanoparticles or buried interfaces as well as the molecular orientation of bonds. Selected applications of this advanced ultra-high vacuum instrument demonstrate both its flexibility and capability.

Lubeck, J.; Beckhoff, B.; Fliegauf, R.; Holfelder, I.; Hoenicke, P.; Mueller, M.; Pollakowski, B.; Reinhardt, F.; Weser, J. [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany)

2013-04-15T23:59:59.000Z

497

Target Diagnostic Instrument-Based Controls Framework for the National Ignition Facility (NIF)  

SciTech Connect (OSTI)

The extreme physics of targets shocked by NIF's 192-beam laser are observed by a diverse suite of diagnostics including optical backscatter, time-integrated and gated X-ray sensors, and laser velocity interferometry. Diagnostics to diagnose fusion ignition implosion and neutron emissions are being planned. Many diagnostics will be developed by collaborators at other sites, but ad hoc controls could lead to unreliable and costly operations. An instrument-based controls (I-BC) framework for both hardware and software facilitates development and eases integration. Each complex diagnostic typically uses an ensemble of electronic instruments attached to sensors, digitizers, cameras, and other devices. In the I-BC architecture each instrument is interfaced to a low-cost Windows XP processor and Java application. Each instrument is aggregated with others as needed in the supervisory system to form an integrated diagnostic. The Java framework provides data management, control services and operator GUI generation. I-BCs are reusable by replication and reconfiguration for specific diagnostics in XML. Advantages include minimal application code, easy testing, and better reliability. Collaborators save costs by assembling diagnostics with existing I-BCs. This paper discusses target diagnostic instrumentation used on NIF and presents the I-BC architecture and framework.

Shelton, R T; O'Brien, D W; Kamperschroer, J H; Nelson, J R

2007-10-03T23:59:59.000Z

498

Developing an Instrumentation Package for in-Water Testing of Marine Hydrokinetic Energy Devices: Preprint  

SciTech Connect (OSTI)

The ocean-energy industry is still in its infancy and device developers have provided their own equipment and procedures for testing. Currently, no testing standards exist for ocean energy devices in the United States. Furthermore, as prototype devices move from the test tank to in-water testing, the logistical challenges and costs grow exponentially. Development of a common instrumentation package that can be moved from device to device is one means of reducing testing costs and providing normalized data to the industry as a whole. As a first step, the U.S. National Renewable Energy Laboratory (NREL) has initiated an effort to develop an instrumentation package to provide a tool to allow common measurements across various ocean energy devices. The effort is summarized in this paper. First, we present the current status of ocean energy devices. We then review the experiences of the wind industry in its development of the instrumentation package and discuss how they can be applied in the ocean environment. Next, the challenges that will be addressed in the development of the ocean instrumentation package are discussed. For example, the instrument package must be highly adaptable to fit a large array of devices but still conduct common measurements. Finally, some possible system configurations are outlined followed by input from the industry regarding its measurement needs, lessons learned from prior testing, and other ideas.

Nelson, E.

2010-08-01T23:59:59.000Z

499

Multimode imaging device  

DOE Patents [OSTI]

Apparatus for detecting and locating a source of gamma rays of energies ranging from 10-20 keV to several MeV's includes plural gamma ray detectors arranged in a generally closed extended array so as to provide Compton scattering imaging and coded aperture imaging simultaneously. First detectors are arranged in a spaced manner about a surface defining the closed extended array which may be in the form a circle, a sphere, a square, a pentagon or higher order polygon. Some of the gamma rays are absorbed by the first detectors closest to the gamma source in Compton scattering, while the photons that go unabsorbed by passing through gaps disposed between adjacent first detectors are incident upon second detectors disposed on the side farthest from the gamma ray source, where the first spaced detectors form a coded aperture array for two or three dimensional gamma ray source detection.

Mihailescu, Lucian; Vetter, Kai M

2013-08-27T23:59:59.000Z

500

Imaging alpha particle detector  

DOE Patents [OSTI]

A method and apparatus for detecting and imaging alpha particles sources is described. A dielectric coated high voltage electrode and a tungsten wire grid constitute a diode configuration discharge generator for electrons dislodged from atoms or molecules located in between these electrodes when struck by alpha particles from a source to be quantitatively or qualitatively analyzed. A thin polyester film window allows the alpha particles to pass into the gas enclosure and the combination of the glass electrode, grid and window is light transparent such that the details of the source which is imaged with high resolution and sensitivity by the sparks produced can be observed visually as well. The source can be viewed directly, electronically counted or integrated over time using photographic methods. A significant increase in sensitivity over other alpha particle detectors is observed, and the device has very low sensitivity to gamma or beta emissions which might otherwise appear as noise on the alpha particle signal.

Anderson, D.F.

1980-10-29T23:59:59.000Z