National Library of Energy BETA

Sample records for image logs insar

  1. COMPARISON OF ACOUSTIC AND ELECTRICAL IMAGE LOGS FROM THE COSO...

    Open Energy Info (EERE)

    image log, but locally approach 100%. This fabric is unlikely to contribute to permeability in the reservoir. Acoustic image logs reveal a similar natural fracture population,...

  2. Using dynamic interferometric synthetic aperature radar (InSAR) to image fast-moving surface waves

    DOE Patents [OSTI]

    Vincent, Paul

    2005-06-28

    A new differential technique and system for imaging dynamic (fast moving) surface waves using Dynamic Interferometric Synthetic Aperture Radar (InSAR) is introduced. This differential technique and system can sample the fast-moving surface displacement waves from a plurality of moving platform positions in either a repeat-pass single-antenna or a single-pass mode having a single-antenna dual-phase receiver or having dual physically separate antennas, and reconstruct a plurality of phase differentials from a plurality of platform positions to produce a series of desired interferometric images of the fast moving waves.

  3. Formation Micro-Imager Logs (FMI) | Open Energy Information

    Open Energy Info (EERE)

    Logs (FMI) Jump to: navigation, search OpenEI Reference LibraryAdd to library Web Site: Formation Micro-Imager Logs (FMI) Author Shakeel Ahmed Published Publisher Not...

  4. Mud Logging | Open Energy Information

    Open Energy Info (EERE)

    Well Log Techniques Acoustic Logs Cement Bond Log Cross-Dipole Acoustic Log Caliper Log Chemical Logging Density Log Gamma Log Image Logs Mud Logging Neutron Log Pressure...

  5. Image Logs At Coso Geothermal Area (2011) | Open Energy Information

    Open Energy Info (EERE)

    Date 2011 Usefulness useful DOE-funding Unknown Exploration Basis Determine crustul stress heterogeneity Notes Borehole induced structures in image logs of wells from the Coso...

  6. Spontaneous Potential Well Log | Open Energy Information

    Open Energy Info (EERE)

    Log Chemical Logging Density Log Gamma Log Image Logs Mud Logging Neutron Log Pressure Temperature Log Single-Well and Cross-Well Resistivity Spontaneous Potential Well Log...

  7. Image Logs At Coso Geothermal Area (2004) | Open Energy Information

    Open Energy Info (EERE)

    Coso Geothermal Region Notes During the second year of this project, wellbore logs and stress data were acquired in a new production well drilled in the Coso Geothermal Field,...

  8. Detecting and monitoring UCG subsidence with InSAR

    SciTech Connect (OSTI)

    Mellors, R J; Foxall, W; Yang, X

    2012-03-23

    The use of interferometric synthetic aperture radar (InSAR) to measure surface subsidence caused by Underground Coal Gasification (UCG) is tested. InSAR is a remote sensing technique that uses Synthetic Aperture Radar images to make spatial images of surface deformation and may be deployed from satellite or an airplane. With current commercial satellite data, the technique works best in areas with little vegetation or farming activity. UCG subsidence is generally caused by roof collapse, which adversely affects UCG operations due to gas loss and is therefore important to monitor. Previous studies have demonstrated the usefulness of InSAR in measuring surface subsidence related to coal mining and surface deformation caused by a coal mining roof collapse in Crandall Canyon, Utah is imaged as a proof-of-concept. InSAR data is collected and processed over three known UCG operations including two pilot plants (Majuba, South Africa and Wulanchabu, China) and an operational plant (Angren, Uzbekistan). A clear f eature showing approximately 7 cm of subsidence is observed in the UCG field in Angren. Subsidence is not observed in the other two areas, which produce from deeper coal seams and processed a smaller volume. The results show that in some cases, InSAR is a useful tool to image UCG related subsidence. Data from newer satellites and improved algorithms will improve effectiveness.

  9. Category:Well Log Techniques | Open Energy Information

    Open Energy Info (EERE)

    1 pages C Caliper Log 1 pages Chemical Logging 1 pages D Density Log 1 pages G Gamma Log 1 pages I Image Logs 1 pages M Mud...

  10. InSAR | Open Energy Information

    Open Energy Info (EERE)

    2007) Unspecified Advances In Geothermal Resource Exploration Circa 2007 InSAR At Brady Hot Springs Area (Laney, 2005) Brady Hot Springs Area Federal Geothermal Research...

  11. INVESTIGATION OF CRUSTAL MOTION IN THE TIEN SHAN USING INSAR

    SciTech Connect (OSTI)

    Mellors, R J

    2011-02-25

    The northern Tien Shan of Central Asia is an area of active mid-continent deformation. Although far from a plate boundary, this region has experienced 5 earthquakes larger than magnitude 7 in the past century and includes one event that may as be as large as Mw 8.0. Previous studies based on GPS measurements indicate on the order of 23 mm/yr of shortening across the entire Tien Shan and up to 15 mm/year in the northern Tien Shan (Figure 1). The seismic moment release rate appears comparable with the geodetic measured slip, at least to first order, suggesting that geodetic rates can be considered a proxy for accumulation rates of stress for seismic hazard estimation. Interferometric synthetic aperture radar may provide a means to make detailed spatial measurements and hence in identifying block boundaries and assisting in seismic hazard. Therefore, we hoped to define block boundaries by direct measurement and by identifying and resolving earthquake slip. Due to political instability in Kyrgzystan, the existing seismic network has not performed as well as required to precisely determine earthquake hypocenters in remote areas and hence InSAR is highly useful. In this paper we present the result of three earthquake studies and show that InSAR is useful for refining locations of teleseismically located earthquakes. ALOS PALSAR data is used to investigate crustal motion in the Tien Shan mountains of Central Asia. As part of the work, considerable software development was undertaken to process PALSAR data. This software has been made freely available. Two damaging earthquakes have been imaged in the Tien Shan and the locations provided by ALOS InSAR have helped to refine seismological velocity models. A third earthquake south of Kyrgyzstan was also imaged. The use of InSAR data and especially L band is therefore very useful in providing groundtruth for earthquake locations.

  12. Change Log

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    NERSC-8 Trinity Benchmarks Change Log 09032013 Correction applied to MiniDFT web-page ... results spreadsheet (linked on SSP web page); clarification to benchmark run rules ...

  13. Change Log

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Change Log Change Log Crossroads/NERSC-9 Benchmarks Change Log 05/10/2016 Updated SNAP: New source distribution, LANL release version 1.07 -- See snap_release_v1.07.txt in the distribution for a list of changes. -- Now using Grind Time as the figure of merit. New Edison baseline performance values. Updated SSI Spreadsheet: Changed SNAP metric to Grind Time and updated Edison reference value. 04/13/2016 Updated GTC-P: Edison SSI reference time was updated. With the source changes made on

  14. Change Log

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Change Log Change Log NERSC-8 / Trinity Benchmarks Change Log 09/03/2013 Correction applied to MiniDFT web-page (to remove inconsistency with MiniDFT README). Capability Improvement measurements do not require 10,000 MPI ranks per k-point. 08/06/2013 Various pages have changed to remove "draft" status 08/02/2013 Correction added to FLOP Counts for "Small" Single-Node Miniapplication Tests page 07/12/2013 README files updated for IOR benchmark to correct an error in wording

  15. Advanced InSAR Techniques for Geothermal Exploration and Production...

    Open Energy Info (EERE)

    how these techniques are being used for different stages of geothermal exploration and management. In both cases, multiple advanced InSAR techniques were used to quantify...

  16. Monitoring EGS Stimulation and Reservoir Dynamics with InSAR...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    EGS Stimulation and Reservoir Dynamics with InSAR and MEQ Monitoring EGS Stimulation and ... and Productivity in Enhanced Geothermal Systems GBCGE Resarch, Education and Outreach ...

  17. InSAR (Monaster And Coolbaugh, 2007) | Open Energy Information

    Open Energy Info (EERE)

    Details Location Unspecified Exploration Technique InSAR Activity Date Usefulness useful DOE-funding Unknown References Francis C. Monastero, Mark F. Coolbaugh (2007) Advances...

  18. Image Logs | Open Energy Information

    Open Energy Info (EERE)

    StratigraphicStructural: -Fault and fracture identification -Rock texture, porosity, and stress analysis -determine dip, thickness, and geometry of rock strata in vicinity of...

  19. Well Log ETL tool

    Energy Science and Technology Software Center (OSTI)

    2013-08-01

    This is an executable python script which offers two different conversions for well log data: 1) Conversion from a BoreholeLASLogData.xls model to a LAS version 2.0 formatted XML file. 2) Conversion from a LAS 2.0 formatted XML file to an entry in the WellLog Content Model. Example templates for BoreholeLASLogData.xls and WellLogsTemplate.xls can be found in the package after download.

  20. Caliper Log | Open Energy Information

    Open Energy Info (EERE)

    Information Exploration Group: Downhole Techniques Exploration Sub Group: Well Log Techniques Parent Exploration Technique: Well Log Techniques Information Provided by...

  1. Log-Tool

    Energy Science and Technology Software Center (OSTI)

    2012-05-21

    Log files are typically semi- or un-structured. To be useable for visualization and machine learning, they need to be parsed into a standard, structured format. Log-tool is a tool for facilitating the parsing, structuring, and routing of log files (e.g. intrusion detection long, web server logs, system logs). It consists of three main components: (1) Input – it will input data from files, standard input, and syslog, (2) Parser – it will parse the logmore » file based on regular expressions into structured data (JSNO format), (3) Output – it will output structured data into commonly used formats, including Redis (a database), standard output, and syslog.« less

  2. Logging in to Franklin

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Logging in Logging in to Franklin Interactive Access You can log in to Franklin using SSH (Secure Shell) with the following command from any UNIX, Linux, FreeBSD, etc. command shell or terminal: % ssh -l username franklin.nersc.gov There are a number of SSH-capable clients available for Windows, Mac, and UNIX/Linux machines. NERSC does not support or recommend any particular client. Franklin has 10 login nodes; you will be randomly connected to one of those 10 when you ssh to franklin.nersc.gov.

  3. InSAR At Walker-Lane Transitional Zone Region (Laney, 2005) ...

    Open Energy Info (EERE)

    Zone Region (Laney, 2005) Exploration Activity Details Location Walker-Lane Transition Zone Geothermal Region Exploration Technique InSAR Activity Date Usefulness useful...

  4. InSAR At Brady Hot Springs Area (Oppliger, Et Al., 2004) | Open...

    Open Energy Info (EERE)

    to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: InSAR At Brady Hot Springs Area (Oppliger, Et Al., 2004) Exploration Activity Details Location Brady...

  5. Acoustic Logs | Open Energy Information

    Open Energy Info (EERE)

    different types of acoustic logs are used, based on the frequencies used, the way the signal is recorded, and the purpose of the log. All these logs require fluid in the well to...

  6. Density Log | Open Energy Information

    Open Energy Info (EERE)

    Density Log Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: Density Log Details Activities (7) Areas (6) Regions (0) NEPA(0) Exploration...

  7. NMR logging apparatus

    SciTech Connect (OSTI)

    Walsh, David O; Turner, Peter

    2014-05-27

    Technologies including NMR logging apparatus and methods are disclosed. Example NMR logging apparatus may include surface instrumentation and one or more downhole probes configured to fit within an earth borehole. The surface instrumentation may comprise a power amplifier, which may be coupled to the downhole probes via one or more transmission lines, and a controller configured to cause the power amplifier to generate a NMR activating pulse or sequence of pulses. Impedance matching means may be configured to match an output impedance of the power amplifier through a transmission line to a load impedance of a downhole probe. Methods may include deploying the various elements of disclosed NMR logging apparatus and using the apparatus to perform NMR measurements.

  8. Logs Perl Module

    Energy Science and Technology Software Center (OSTI)

    2007-04-04

    A perl module designed to read and parse the voluminous set of event or accounting log files produced by a Portable Batch System (PBS) server. This module can filter on date-time and/or record type. The data can be returned in a variety of formats.

  9. Log in | The Ames Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Error message Access denied. You must log in to view this page.

  10. Neutron Log | Open Energy Information

    Open Energy Info (EERE)

    Dictionary.png Neutron Log: The neutron log responds primarily to the amount of hydrogen in the formation which is contained in oil, natural gas, and water. The amount of...

  11. Grid Logging: Best Practices Guide

    SciTech Connect (OSTI)

    Tierney, Brian L; Tierney, Brian L; Gunter, Dan

    2008-04-01

    The purpose of this document is to help developers of Grid middleware and application software generate log files that will be useful to Grid administrators, users, developers and Grid middleware itself. Currently, most of the currently generated log files are only useful to the author of the program. Good logging practices are instrumental to performance analysis, problem diagnosis, and security auditing tasks such as incident tracing and damage assessment. This document does not discuss the issue of a logging API. It is assumed that a standard log API such as syslog (C), log4j (Java), or logger (Python) is being used. Other custom logging API or even printf could be used. The key point is that the logs must contain the required information in the required format. At a high level of abstraction, the best practices for Grid logging are: (1) Consistently structured, typed, log events; (2) A standard high-resolution timestamp; (3) Use of logging levels and categories to separate logs by detail and purpose; (4) Consistent use of global and local identifiers; and (5) Use of some regular, newline-delimited ASCII text format. The rest of this document describes each of these recommendations in detail.

  12. InSAR At Redfield Campus Area (Oppliger, Et Al., 2008) | Open...

    Open Energy Info (EERE)

    All InSAR pairs were systematically screened to determine those suitable for further processing based on signal-to-noise and data integrity around the Redfield campus and...

  13. Monitoring EGS Stimulation and Reservoir Dynamics with InSAR and MEQ |

    Broader source: Energy.gov (indexed) [DOE]

    Mona Khalil - Policy Advisor, Weatherization and Intergovernmental Program Most Recent Mississippi Adopts New Rules to Save Energy, Money November 8 Department of Energy

    Monitoring EGS Stimulation and Reservoir Dynamics with InSAR and MEQ presentation at the April 2013 peer review meeting held in Denver, Colorado. PDF icon monitoring_egs_insar_meq_peer2013.pdf More Documents & Publications Novel use of 4D Monitoring Techniques to Improve Reservoir Longevity and Productivity in

  14. Category:Chemical Logging | Open Energy Information

    Open Energy Info (EERE)

    Chemical Logging Jump to: navigation, search Geothermalpower.jpg Looking for the Chemical Logging page? For detailed information on Chemical Logging, click here. Category:Chemical...

  15. Geotech Logging Services | Open Energy Information

    Open Energy Info (EERE)

    Logging Services Jump to: navigation, search OpenEI Reference LibraryAdd to library Web Site: Geotech Logging Services Author Geotech Logging Servces LLC Published Publisher...

  16. Coiled-tubing logging system

    SciTech Connect (OSTI)

    Howell, E.P.; Smith, L.J.; Blount, C.G.

    1988-03-01

    Techniques have been developed to use coiled tubing containing a seven-conductor wireline to facilitate logging operations. Equipment has been designed to permit the connection of conventional logging tools to the tubing and the recording of logs. Operating techniques have been developed and applied under various wellbore conditions. The system allows traditional log measurements in a well while wellbore conditions are controlled. Advantages of the system include reduced wellbore pressure during peroration to maximize perforation performance; lubrication during pulling or pushing a logging tool through a borehole so that a more uniform velocity can be maintained with a logging sonde; continued circulation and thus borehole stability during logging; temperature reduction for improved reliability of logging sonde electronics in hot holes; and more stable positioning of perforation equipment. The ability of coiled tubing to push tools down highly deviated or horizontal wellbores makes logging or perforating feasible in these wells. Expenses can often be reduced with coiled-tubing logging because a rig is unnecessary during many operations.

  17. Coiled-tubing logging system

    SciTech Connect (OSTI)

    Howell, E.P.; Smith, L.J.; Blount, C.G.

    1986-01-01

    Techniques have been developed which use coiled tubing containing a seven-conductor wireline to facilitate logging operations. Equipment has been designed which permits the connection of conventional logging tools to the tubing and the recording of logs. Also, operating techniques have been developed and applied under various wellbore conditions. The system allows traditional log measurements in a well while controlling wellbore conditions. Advantages of the system include: reduced wellbore pressure during perforation to minimize formation damage: lubrication while pulling or pushing a logging tool through a borehole so that a more uniform velocity can be maintained with a logging sonde; continued circulation and thus borehole stability while logging; temperature reduction for improved reliability of logging sonde electronics in hot holes; and more stable positioning of perforation equipment. The ability of coiled tubing to push tools down highly deviated, or even horizontal wellbores, makes logging or perforating feasible in these wells. Expenses can often be reduced with coiled-tubing logging, since a rig is unnecessary during many operations.

  18. Acoustic paramagnetic logging tool

    DOE Patents [OSTI]

    Vail, III, William B.

    1988-01-01

    New methods and apparatus are disclosed which allow measurement of the presence of oil and water in geological formations using a new physical effect called the Acoustic Paramagnetic Logging Effect (APLE). The presence of petroleum in formation causes a slight increase in the earth's magnetic field in the vicinity of the reservoir. This is the phenomena of paramagnetism. Application of an acoustic source to a geological formation at the Larmor frequency of the nucleons present causes the paramagnetism of the formation to disappear. This results in a decrease in the earth3 s magnetic field in the vicinity of the oil bearing formation. Repetitively frequency sweeping the acoustic source through the Larmor frequency of the nucleons present (approx. 2 kHz) causes an amplitude modulation of the earth's magnetic field which is a consequence of the APLE. The amplitude modulation of the earth's magnetic field is measured with an induction coil gradiometer and provides a direct measure of the amount of oil and water in the excitation zone of the formation . The phase of the signal is used to infer the longitudinal relaxation times of the fluids present, which results in the ability in general to separate oil and water and to measure the viscosity of the oil present. Such measurements may be preformed in open boreholes and in cased well bores.

  19. Chemical Logging | Open Energy Information

    Open Energy Info (EERE)

    concentrations.1 Use in Geothermal Exploration During a chemical logging study at the Raft River Geothermal Test Site, returned drilling fluid samples were collected every...

  20. Category:Neutron Log | Open Energy Information

    Open Energy Info (EERE)

    Looking for the Neutron Log page? For detailed information on Neutron Log, click here. Category:Neutron Log Add.png Add a new Neutron Log Technique Pages in category...

  1. A new approach for deriving pseudovelocity logs from resistivity logs

    SciTech Connect (OSTI)

    Dos Santos, W.L.B.; Ulrych, T.J.; De Lima, O.A.L.

    1988-01-01

    This paper describes a method of generating pseudovelocity logs using measurements of electrical resistivity. A theoretical relation between electrical resistivity and transit time, which is applicable to a wide range of lithologies, has been developed. The application of this relation using a method which defines lithoresistivity zones as lithological intervals related to the same formation and showing small resistivity variations, has been tested in the Reconcavo sedimentary basin in Bahia, Brazil. A comparison of derived pseudovelocity logs with actual sonic logs for five wells shows the validity of the present approach.

  2. Well Log Techniques | Open Energy Information

    Open Energy Info (EERE)

    formation properties versus depth in a borehole. Other definitions:Wikipedia Reegle Introduction Well logging, also known as wireline logging, is a method of data collection in the...

  3. Vertical Flowmeter Logging | Open Energy Information

    Open Energy Info (EERE)

    Logging Jump to: navigation, search OpenEI Reference LibraryAdd to library Web Site: Vertical Flowmeter Logging Author U.S. Geological Survey Published USGS Groundwater...

  4. Well Log Techniques At Raft River Geothermal Area (1977) | Open...

    Open Energy Info (EERE)

    the rock using well log data. Notes Information is given on the following logs: dual-induction focused log, including resistivity, sp, and conductivity; acoustic log; compensated...

  5. Chemical logging of geothermal wells

    DOE Patents [OSTI]

    Allen, Charles A.; McAtee, Richard E.

    1981-01-01

    The presence of geothermal aquifers can be detected while drilling in geothermal formations by maintaining a chemical log of the ratio of the concentrations of calcium to carbonate and bicarbonate ions in the return drilling fluid. A continuous increase in the ratio of the concentrations of calcium to carbonate and bicarbonate ions is indicative of the existence of a warm or hot geothermal aquifer at some increased depth.

  6. Chemical logging of geothermal wells

    DOE Patents [OSTI]

    Allen, C.A.; McAtee, R.E.

    The presence of geothermal aquifers can be detected while drilling in geothermal formations by maintaining a chemical log of the ratio of the concentrations of calcium to carbonate and bicarbonate ions in the return drilling fluid. A continuous increase in the ratio of the concentrations of calcium to carbonate and bicarbonate ions is indicative of the existence of a warm or hot geothermal aquifer at some increased depth.

  7. Borehole Geophysical Logging | Open Energy Information

    Open Energy Info (EERE)

    Logging Jump to: navigation, search OpenEI Reference LibraryAdd to library Web Site: Borehole Geophysical Logging Authors Hager-Richter Geoscience and Inc. Published Publisher Not...

  8. Energy Citations Database (ECD) - Alerts Log On

    Office of Scientific and Technical Information (OSTI)

    Log On You must Log On to use the ECD Alerts. Alerts provide users with e-mail notification of updates to the ECD in specific areas of interest. If you wish to receive an Alert and...

  9. Leak checker data logging system

    DOE Patents [OSTI]

    Gannon, J.C.; Payne, J.J.

    1996-09-03

    A portable, high speed, computer-based data logging system for field testing systems or components located some distance apart employs a plurality of spaced mass spectrometers and is particularly adapted for monitoring the vacuum integrity of a long string of a superconducting magnets such as used in high energy particle accelerators. The system provides precise tracking of a gas such as helium through the magnet string when the helium is released into the vacuum by monitoring the spaced mass spectrometers allowing for control, display and storage of various parameters involved with leak detection and localization. A system user can observe the flow of helium through the magnet string on a real-time basis hour the exact moment of opening of the helium input valve. Graph reading can be normalized to compensate for magnet sections that deplete vacuum faster than other sections between testing to permit repetitive testing of vacuum integrity in reduced time. 18 figs.

  10. Leak checker data logging system

    DOE Patents [OSTI]

    Gannon, Jeffrey C.; Payne, John J.

    1996-01-01

    A portable, high speed, computer-based data logging system for field testing systems or components located some distance apart employs a plurality of spaced mass spectrometers and is particularly adapted for monitoring the vacuum integrity of a long string of a superconducting magnets such as used in high energy particle accelerators. The system provides precise tracking of a gas such as helium through the magnet string when the helium is released into the vacuum by monitoring the spaced mass spectrometers allowing for control, display and storage of various parameters involved with leak detection and localization. A system user can observe the flow of helium through the magnet string on a real-time basis hour the exact moment of opening of the helium input valve. Graph reading can be normalized to compensate for magnet sections that deplete vacuum faster than other sections between testing to permit repetitive testing of vacuum integrity in reduced time.

  11. Request Log Closedl Date Yes

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    6 FOIA - Request Log Closedl Date Yes 01 127106 Yes 02/23/06 Yes 04/05/06 Yes 04/03/06 Yes 04/03/06 Yes 05/22/06 Yes 35/30/06 - No. - 00 1 - 002 - 003 - 004 005 006 - 307 - Dated 01 125106 0211 6106 03/29/06 03/31 106 14/03/06 1511 8/06 )5/22/06 Date Rec'd 0 I I2 5/06 02/23/06 03130/06 0313 1 106 04/03/06 05/22/06 05/22/06 HQ or Dir. Direct Transfer from HQ Direct Trans from HQ Direct Direct Transfer 'rom HQ Subject Requesting a list of all your Procurement card holders Requesting copies of any

  12. Logging Calibration Models for Fission Neutron Sondes (September...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Logging Calibration Models for Fission Neutron Sondes (September 1981) Logging Calibration Models for Fission Neutron Sondes (September 1981) Logging Calibration Models for Fission ...

  13. Proven logging technology for high temperatures

    SciTech Connect (OSTI)

    Gonzalez, M.E.

    1995-12-01

    Los Alamos National Laboratory (LANL) hot-hole logging technology for geothermal projects was retrofitted into cased-hole logging tools (gamma ray, neutron and casing collar) for use in deep gas wells. Lab tests indicated that hot-hole tools would last three times longer at 400 F (204 C) bottomhole conditions. During logging runs in Western Oklahoma, Beckham County deep gas wells, standard cased-hole logging tools failed in two to four hours, but hot-hole tools ran successfully for two consecutive six-hour logging runs (12 hours). Subsequent to this, retrofitted tools were equally effective in South Texas and Wyoming. This paper reviews results and design of this equipment.

  14. Formation mechanical properties and the sonic log

    SciTech Connect (OSTI)

    Elphick, R.Y.

    1988-11-01

    A program is presented that calculates the mechanical properties of reservoir rocks from sonic logs. The program was written in Microsoft BASIC and the source code for MS-DOS, Apple Macintosh, and Amiga personal computers is given.

  15. Sisyphus - An Event Log Analysis Toolset

    Energy Science and Technology Software Center (OSTI)

    2004-09-01

    Event logs are a ubiquitous source of system feedback from computer systems, but have widely ranging format and can be extremely numerous, particularly from systems with many logging components. Inspection of these logs is fundamental to system debugging; increased capability to quickly extract meaningful information will impact MTTR (mean time to repair) and may impact MTBF (mean time between failure). Sisyphus is a machine-leanring analysis system whose goal is to enable content-novice analysts to efficieniiymore » understand evolving trends, identify anomalies, and investigate cause-effect hypotheses in large multiple-souce log sets. The toolkit is comprised a framework for utilizing third-party frequentitemset data mining tools Teiresias and SLCT. and software to cluster messages according to time statistics, and an interactive results viewer.« less

  16. Logging-while-coring method and apparatus

    DOE Patents [OSTI]

    Goldberg, David S.; Myers, Gregory J.

    2007-01-30

    A method and apparatus for downhole coring while receiving logging-while-drilling tool data. The apparatus includes core collar and a retrievable core barrel. The retrievable core barrel receives core from a borehole which is sent to the surface for analysis via wireline and latching tool The core collar includes logging-while-drilling tools for the simultaneous measurement of formation properties during the core excavation process. Examples of logging-while-drilling tools include nuclear sensors, resistivity sensors, gamma ray sensors, and bit resistivity sensors. The disclosed method allows for precise core-log depth calibration and core orientation within a single borehole, and without at pipe trip, providing both time saving and unique scientific advantages.

  17. Logging-while-coring method and apparatus

    DOE Patents [OSTI]

    Goldberg, David S.; Myers, Gregory J.

    2007-11-13

    A method and apparatus for downhole coring while receiving logging-while-drilling tool data. The apparatus includes core collar and a retrievable core barrel. The retrievable core barrel receives core from a borehole which is sent to the surface for analysis via wireline and latching tool The core collar includes logging-while-drilling tools for the simultaneous measurement of formation properties during the core excavation process. Examples of logging-while-drilling tools include nuclear sensors, resistivity sensors, gamma ray sensors, and bit resistivity sensors. The disclosed method allows for precise core-log depth calibration and core orientation within a single borehole, and without at pipe trip, providing both time saving and unique scientific advantages.

  18. CMLOG: A common message logging system

    SciTech Connect (OSTI)

    Chen, J.; Akers, W.; Bickley, M.; Wu, D.; Watson, W. III

    1997-12-01

    The Common Message Logging (CMLOG) system is an object-oriented and distributed system that not only allows applications and systems to log data (messages) of any type into a centralized database but also lets applications view incoming messages in real-time or retrieve stored data from the database according to selection rules. It consists of a concurrent Unix server that handles incoming logging or searching messages, a Motif browser that can view incoming messages in real-time or display stored data in the database, a client daemon that buffers and sends logging messages to the server, and libraries that can be used by applications to send data to or retrieve data from the database via the server. This paper presents the design and implementation of the CMLOG system meanwhile it will also address the issue of integration of CMLOG into existing control systems.

  19. Cement Bond Log | Open Energy Information

    Open Energy Info (EERE)

    casing and cement and between cement and borehole wall. Most cement-bond logs are a measurement only of the amplitude of the early arriving casing signal. Although a small...

  20. Energy Citations Database (ECD) - Alerts Log On

    Office of Scientific and Technical Information (OSTI)

    ECD Alerts Log On Alerts provide users with e-mail notification of updates to the ECD in specific areas of interest. If you wish to receive an Alert and are not registered, please...

  1. Property:FirstWellLog | Open Energy Information

    Open Energy Info (EERE)

    FirstWellLog Jump to: navigation, search Property Name FirstWellLog Property Type Page Retrieved from "http:en.openei.orgwindex.php?titleProperty:FirstWellLog&oldid598766...

  2. Category:Pressure Temperature Log | Open Energy Information

    Open Energy Info (EERE)

    Geothermalpower.jpg Looking for the Pressure Temperature Log page? For detailed information on Pressure Temperature Log, click here. Category:Pressure Temperature Log Add.png Add a...

  3. Category:Cross-Dipole Acoustic Log | Open Energy Information

    Open Energy Info (EERE)

    Cross-Dipole Acoustic Log Jump to: navigation, search Geothermalpower.jpg Looking for the Cross-Dipole Acoustic Log page? For detailed information on Cross-Dipole Acoustic Log,...

  4. Property:ThermalInfo | Open Energy Information

    Open Energy Info (EERE)

    G cont. Geodetic Survey Geophysical Methods Geothermal Literature Review Gravity Methods Ground Magnetics H Hand-held X-Ray Fluorescence (XRF) I Image Logs InSAR Injectivity Test...

  5. Chemical Logging At North Brawley Geothermal Area (Department...

    Open Energy Info (EERE)

    Chemical logs were made from well fluids for analysis when designing the first experimental power plant Notes Detailed logs of well fluids were recorded. Non-condensable gases...

  6. Manager's Signature Log Privacy Impact Assessment, Office of...

    Office of Environmental Management (EM)

    Manager's Signature Log Privacy Impact Assessment, Office of Science Chicago Office Manager's Signature Log Privacy Impact Assessment, Office of Science Chicago Office Manager's ...

  7. Green Energy Resources Inc formerly New York International Log...

    Open Energy Info (EERE)

    Inc formerly New York International Log Lumber Company Jump to: navigation, search Name: Green Energy Resources Inc (formerly New York International Log & Lumber Company) Place:...

  8. Energy Efficiency in Log Homes | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    energy efficiency when designing or purchasing a log home. | Photo courtesy of iStockphoto.comtinabelle Consider energy efficiency when designing or purchasing a log home. |...

  9. Pressure Temperature Log At Vale Hot Springs Area (Combs, Et...

    Open Energy Info (EERE)

    Unknown Notes Numerous temperature logs were taken with Sandia's platinum-resistance-thermometer (PRT) tool which along with a Sandia logging truck remained on-site for...

  10. Logjam: A scalable unified log file archiver

    Energy Science and Technology Software Center (OSTI)

    2001-08-01

    Log files are a necessary record of events on any system. However, as systems scale, so does the volume of data captured. To complicate matters, this data can be distributed across all nodes within the system. This creates challenges in ways to obtain these files as well as archiving them in a consistent manner. It has become commonplace to develop a custom written utility for each system that is tailored specifically to that system. Formore » computer centers that contain multiple systems, each system would have their own respective utility for gathering and archiving log files. Each time a new log file is produced, a modification to the utility is necessary. With each modification, risks of errors could be introduced as well as spending time to introduce that change. This is precisely the purpose of logjam. Once installed, the code only requires modification when new features are required. A configuration file is used to identify each log file as well as where to harvest it and how to archive it. Adding a new log file is as simple as defining it in a configuration file and testing can be performed in the production environment.« less

  11. Development of pulsed neutron uranium logging instrument

    SciTech Connect (OSTI)

    Wang, Xin-guang; Liu, Dan; Zhang, Feng

    2015-03-15

    This article introduces a development of pulsed neutron uranium logging instrument. By analyzing the temporal distribution of epithermal neutrons generated from the thermal fission of {sup 235}U, we propose a new method with a uranium-bearing index to calculate the uranium content in the formation. An instrument employing a D-T neutron generator and two epithermal neutron detectors has been developed. The logging response is studied using Monte Carlo simulation and experiments in calibration wells. The simulation and experimental results show that the uranium-bearing index is linearly correlated with the uranium content, and the porosity and thermal neutron lifetime of the formation can be acquired simultaneously.

  12. Logging of subterranean wells using coiled tubing

    SciTech Connect (OSTI)

    Pilla, J.

    1991-01-15

    This patent describes an apparatus for production logging of a well utilizing artificial lift in a wellbore. It comprises: coiled tubing extending into the wellbore having wireline electrical cable passing through a central bore thereof and having a remote end within the wellbore which end is connected to gas injector means. The wireline cable passing through the gas injector means to a flexible electrically conductive support spacer having an end portion remote from the gas injector means and logging means connected to the end portion of the support spacer.

  13. Electric Micro Imager Log At Coso Geothermal Area (2003) | Open...

    Open Energy Info (EERE)

    be corrected for well-bore deviation. References Rose, P.; Barton, C.; McCulloch, J.; Moore, J.N.; Kovac, K.; Sheridan, J.; Spielman, P.; Berard, B. (1 January 2003) The Coso EGS...

  14. INSPIRE and SPIRES Log File Analysis

    SciTech Connect (OSTI)

    Adams, Cole; /Wheaton Coll. /SLAC

    2012-08-31

    SPIRES, an aging high-energy physics publication data base, is in the process of being replaced by INSPIRE. In order to ease the transition from SPIRES to INSPIRE it is important to understand user behavior and the drivers for adoption. The goal of this project was to address some questions in regards to the presumed two-thirds of the users still using SPIRES. These questions are answered through analysis of the log files from both websites. A series of scripts were developed to collect and interpret the data contained in the log files. The common search patterns and usage comparisons are made between INSPIRE and SPIRES, and a method for detecting user frustration is presented. The analysis reveals a more even split than originally thought as well as the expected trend of user transition to INSPIRE.

  15. Logs Wood Chips Straw Corn Switchgrass

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Clean energy can come from the sun. The energy in wind can make electricity. Bioenergy comes from plants we can turn into fuel. Logs Wood Chips Straw Corn Switchgrass We can use energy from the earth to heat and cool our homes. Check out these cool websites to learn more about clean energy! U.S. Department of Energy Energy Information Administration Energy Star Kids Energy Education Activities switch on clean energy (EERE) invests in clean energy technologies that strengthen the economy,

  16. Logging while tripping cuts time to run gamma ray

    SciTech Connect (OSTI)

    1996-06-10

    A new logging tool, sent down the drillstring before a pipe trip out of the hole, logs the well as the pipe is pulled from the hole, cutting the total time required for open hole logging on some wells. This logging while tripping (LWT) technology allows an operator to run a gamma ray and neutron log more quickly than with standard wire line equipment. The drill pipe conveys the logging tools up the well as the pipe is tripped out, and the logging data are stored in the tool`s memory. A transparent logging collar, which meets API 7 and RP7G requirements, holds the tools in the drillstring without interfering with the logging measurements.

  17. Energy Efficiency in Log Homes | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Design » Types of Homes » Energy Efficiency in Log Homes Energy Efficiency in Log Homes Consider energy efficiency when designing or purchasing a log home. | Photo courtesy of ©iStockphoto.com/tinabelle Consider energy efficiency when designing or purchasing a log home. | Photo courtesy of ©iStockphoto.com/tinabelle Log homes may be site-built or pre-cut in a factory for delivery to the site. Some log home manufacturers can also customize their designs. Before designing or purchasing a

  18. Geophysical logging case history of the Raft River geothermal...

    Open Energy Info (EERE)

    logging case history of the Raft River geothermal system, Idaho Jump to: navigation, search OpenEI Reference LibraryAdd to library Report: Geophysical logging case history of the...

  19. Geochemical Mud Logging of geothermal drilling

    SciTech Connect (OSTI)

    Tonani, F.B.; Guidi, M.; Johnson, S.D.

    1988-01-01

    The experience and results described in the present paper were developed over nearly two decades, with a major R&D project around 1980. The expression Geochemical Mud Logging (GML) has ill defined meaning in the geothermal industry, and ought to be specified. We refer here to GML as featuring mud and formation fluid tracer(s) and temperature as the bare essentials and with specified accuracies. Air and water logging are expected to be less demanding with regard to analysis accuracy, but are not discussed in this report. During application of GML to several drill holes with low formation permeabilities and under conditions of high temperature and high mud weight, GML as specified, revealed unexpected influx of formation brine. Such influx was a recurring feature that has been referenced to individual fractures and reflects both fracture size and permeability. As a consequence, continuous or subcontinuous sampling of mud systems appears more cost effective than trying to keep up with cumulative changes of bulk mud composition; although, the latter approach is more sensitive to extremely low rate, steady, inflow of formation fluid into the mud system. It appears, that based on this influx of formation fluid, permeability can be estimated well before mud losses are detected and/or drill strings are stuck. The main advantages of GML are: (1) the capability to assess formation temperature and permeability in nearly real time, resulting in (a) assessments of undisturbed formation and (b) having data in hand for holes lost during drilling operations and (2) being effective under conditions of very high temperatures where electrical logs are very costly and less reliable. Estimated cost for GML is $1500 per day (1982) based on assessments of R&D operations. However, extrapolating to larger scale services and to different operating conditions is indeed difficult. GML cost is probably the only significant point of controversy with regard to GML being a viable evaluation tool.

  20. Log amplifier with pole-zero compensation

    DOE Patents [OSTI]

    Brookshier, W.

    1985-02-08

    A logarithmic amplifier circuit provides pole-zero compensation for improved stability and response time over 6-8 decades of input signal frequency. The amplifer circuit includes a first operational amplifier with a first feedback loop which includes a second, inverting operational amplifier in a second feedstock loop. The compensated output signal is provided by the second operational amplifier with the log elements, i.e., resistors, and the compensating capacitors in each of the feedback loops having equal values so that each break point is offset by a compensating break point or zero.

  1. Microsoft Word - FOIA Log FY 2001.doc

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    1 FOIA - Request Log 1 Closed/ Date No. Dated Date Rec'd HQ or Dir. Subject Yes/ 3/29/01 001 02/01/01 02/01/01 01-0021C Transfer AL Copies of all documents including studies and memoranda, which may identify or consider WIPP site in Carlsbad, NM as a potential site for storage or disposal of spent reactor fuel or high-level radioactive wastes 2. All documents including studies, memoranda, hypothesizing, considering, recommending, or suggesting the WIPP site in NM as an alternative site to the

  2. Microsoft Word - FOIA Log FY 2002.doc

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    2 FOIA - Request Log 1 Closed/ Date No. Dated Date Rec'd HQ or Dir. Subject Yes/ 1/30/02 001 12/3/02 12/21/02 Richland Transfer Richland Operation Office search for records they located documents originated by the DOE Carlsbad Field Office that may be responsive to Mr. Hongs request. By transfer of this letter they forwarded Mr. Hong request, along with the documents located at Richland to the Carlsbad FOIA Office. CBFO will respond directly to Mr. Hong with a release determination Yes/ 2/13/02

  3. Log amplifier with pole-zero compensation

    DOE Patents [OSTI]

    Brookshier, William

    1987-01-01

    A logarithmic amplifier circuit provides pole-zero compensation for improved stability and response time over 6-8 decades of input signal frequency. The amplifier circuit includes a first operational amplifier with a first feedback loop which includes a second, inverting operational amplifier in a second feedback loop. The compensated output signal is provided by the second operational amplifier with the log elements, i.e., resistors, and the compensating capacitors in each of the feedback loops having equal values so that each break point or pole is offset by a compensating break point or zero.

  4. Manager's Signature Log Privacy Impact Assessment, Office of Science

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Chicago Office | Department of Energy Manager's Signature Log Privacy Impact Assessment, Office of Science Chicago Office Manager's Signature Log Privacy Impact Assessment, Office of Science Chicago Office Manager's Signature Log Privacy Impact Assessment, Office of Science Chicago Office PDF icon Manager's Signature Log Privacy Impact Assessment, Office of Science Chicago Office More Documents & Publications Integrated Safety Management Workshop Registration, PIA, Idaho National

  5. Well Logging Security Initiatives | Y-12 National Security Complex

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Well Logging Security ... Well Logging Security Initiatives The mp4 video format is not supported by this browser. Download video Captions: On Watch as GTRI demonstrates the threat to the security of (oil) well logging systems and outlines the initiatives that are enhancing the security of these sources worldwide

  6. Dual excitation acoustic paramagnetic logging tool

    DOE Patents [OSTI]

    Vail, III, William B.

    1989-01-01

    New methods and apparatus are disclosed which allow measurement of the presence of oil and water in gelogical formations using a new physical effect called the Acoustic Paramagnetic Logging Effect (APLE). The presence of petroleum in formation causes a slight increase in the earth's magnetic field in the vicinity of the reservoir. This is the phenomena of paramagnetism. Application of an acoustic source to a geological formation at the Larmor frequency of the nucleous present causes the paramagnetism of the formation to disappear. This results in a decrease in the earth's magnetic field in the vicinity of the oil bearing formation. Repetitively frequency sweeping the acoustic source through the Larmor frequency of the nucleons present (approx. 2 kHz) causes an amplitude modulation of the earth's magnetic field which is a consequence of the APLE. The amplitude modulation of the earth's magnetic field is measured with an induction coil gradiometer and provides a direct measure of the amount of oil and water in the excitation zone of the formation. The phase of the signal is used to infer the longitudinal relaxation times of the fluids present, which results in the ability in general to separate oil and water and to measure the viscosity of the oil present. Such measurements may be preformed in open boreholes and in cased well bores. The Dual Excitation Acoustic Paramagnetic Logging Tool employing two acoustic sources is also described.

  7. Dual excitation acoustic paramagnetic logging tool

    DOE Patents [OSTI]

    Vail, W.B. III.

    1989-02-14

    New methods and apparatus are disclosed which allow measurement of the presence of oil and water in geological formations using a new physical effect called the Acoustic Paramagnetic Logging Effect (APLE). The presence of petroleum in formation causes a slight increase in the earth's magnetic field in the vicinity of the reservoir. This is the phenomena of paramagnetism. Application of an acoustic source to a geological formation at the Larmor frequency of the nucleons present causes the paramagnetism of the formation to disappear. This results in a decrease in the earth's magnetic field in the vicinity of the oil bearing formation. Repetitively frequency sweeping the acoustic source through the Larmor frequency of the nucleons present (approx. 2 kHz) causes an amplitude modulation of the earth's magnetic field which is a consequence of the APLE. The amplitude modulation of the earth's magnetic field is measured with an induction coil gradiometer and provides a direct measure of the amount of oil and water in the excitation zone of the formation. The phase of the signal is used to infer the longitudinal relaxation times of the fluids present, which results in the ability in general to separate oil and water and to measure the viscosity of the oil present. Such measurements may be performed in open boreholes and in cased well bores. The Dual Excitation Acoustic Paramagnetic Logging Tool employing two acoustic sources is also described. 6 figs.

  8. Image

    Energy Science and Technology Software Center (OSTI)

    2007-08-31

    The computer side of the IMAGE project consists of a collection of Perl scripts that perform a variety of tasks; scripts are available to insert, update and delete data from the underlying Oracle database, download data from NCBI's Genbank and other sources, and generate data files for download by interested parties. Web scripts make up the tracking interface, and various tools available on the project web-site (image.llnl.gov) that provide a search interface to the database.

  9. Imaging

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Imaging Print The wavelengths of soft x-ray photons (1-15 nm) are very well matched to the creation of "nanoscopes" capable of probing the interior structure of biological cells and inorganic mesoscopic systems.Topics addressed by soft x-ray imaging techniques include cell biology, nanomagnetism, environmental science, and polymers. The tunability of synchrotron radiation is absolutely essential for the creation of contrast mechanisms. Cell biology CAT scans are performed in the

  10. Imaging

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Imaging Print The wavelengths of soft x-ray photons (1-15 nm) are very well matched to the creation of "nanoscopes" capable of probing the interior structure of biological cells and inorganic mesoscopic systems.Topics addressed by soft x-ray imaging techniques include cell biology, nanomagnetism, environmental science, and polymers. The tunability of synchrotron radiation is absolutely essential for the creation of contrast mechanisms. Cell biology CAT scans are performed in the

  11. Western tight gas sands advanced logging workshop proceedings

    SciTech Connect (OSTI)

    Jennings, J B; Carroll, Jr, H B

    1982-04-01

    An advanced logging research program is one major aspect of the Western Tight Sands Program. Purpose of this workshop is to help BETC define critical logging needs for tight gas sands and to allow free interchange of ideas on all aspects of the current logging research program. Sixteen papers and abstracts are included together with discussions. Separate abstracts have been prepared for the 12 papers. (DLC)

  12. Drag reduction in coal log pipelines

    SciTech Connect (OSTI)

    Marrero, T.R.; Liu, H.

    1996-12-31

    It is well-known that solutions of dissolved long-chain macromolecules produce lower friction or drag losses than with the solvent alone. In coal log pipeline (CLP), water is the conveying medium. Synthetic polymers such as poly(ethylene oxide) have been dissolved in water and tested for their extent of drag reduction as a function of concentration and other variables. Lab-scale experimental results for CLP indicate substantial drag reduction at low concentration levels of polymer. But, the macromolecules exhibit degradation under mechanical shear stresses. The large molecules break into smaller units. This degradation effect causes a loss of drag reduction. However, high levels of drag reduction can be maintained as follows: (1) by injecting polymer into the CLP at several locations along the pipeline, (2) by injecting polymer of different particle sizes, (3) by using more robust types of polymers, or (4) by using polymer-fiber mixtures. This report presents the value of drag-reducing agents in terms of pumping power net cost savings. In addition, this report outlines the environmental impact of drag reduction polymers, and end-of-pipeline water treatment processes. For an operating CLP, hundreds of miles in length, the use of poly(ethylene oxide) as a drag reducing agent provides significant pumping power cost savings at a minimal materials cost.

  13. Evaluation of Emerging Technology for Geothermal Drilling and Logging Applications

    Broader source: Energy.gov [DOE]

    Evaluation of Emerging Technology for Geothermal Drilling and Logging Applications presentation at the April 2013 peer review meeting held in Denver, Colorado.

  14. Chemical Logging At Dixie Valley Geothermal Area (Los Alamos...

    Open Energy Info (EERE)

    Dixie Valley Geothermal Area (Los Alamos National Laboratory, NM, 2002) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Chemical Logging At Dixie...

  15. Well Log Techniques At Newberry Caldera Area (DOE GTP) | Open...

    Open Energy Info (EERE)

    navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Well Log Techniques At Newberry Caldera Area (DOE GTP) Exploration Activity Details Location Newberry...

  16. Well Log Techniques At Coso Geothermal Area (1985) | Open Energy...

    Open Energy Info (EERE)

    navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Well Log Techniques At Coso Geothermal Area (1985) Exploration Activity Details Location Coso Geothermal...

  17. Borehole Logging Methods for Exploration and Evaluation of Uranium...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    for Models Used for Calibration of Gross-Count Gamma-Ray Logging Systems (December 1983) Parameter Assignments for Spectral Gamma-Ray Borehole Calibration Models (April 1984

  18. Gamma-Ray Logging Workshop (February 1981) | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    for Models Used for Calibration of Gross-Count Gamma-Ray Logging Systems (December 1983) Parameter Assignments for Spectral Gamma-Ray Borehole Calibration Models (April 1984)

  19. Pressure Temperature Log At Fort Bliss Area (DOE GTP) | Open...

    Open Energy Info (EERE)

    navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Pressure Temperature Log At Fort Bliss Area (DOE GTP) Exploration Activity Details Location Fort Bliss...

  20. Pressure Temperature Log At Silver Peak Area (DOE GTP) | Open...

    Open Energy Info (EERE)

    navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Pressure Temperature Log At Silver Peak Area (DOE GTP) Exploration Activity Details Location Silver Peak...

  1. Pressure Temperature Log At Flint Geothermal Area (DOE GTP) ...

    Open Energy Info (EERE)

    navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Pressure Temperature Log At Flint Geothermal Area (DOE GTP) Exploration Activity Details Location Flint...

  2. Pressure Temperature Log At Glass Buttes Area (DOE GTP) | Open...

    Open Energy Info (EERE)

    navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Pressure Temperature Log At Glass Buttes Area (DOE GTP) Exploration Activity Details Location Glass...

  3. Acoustic Logs At Coso Geothermal Area (2005) | Open Energy Information

    Open Energy Info (EERE)

    Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Acoustic Logs At Coso Geothermal Area (2005) Exploration Activity Details Location Coso...

  4. Chemical logging- a geothermal technique | Open Energy Information

    Open Energy Info (EERE)

    technique Abstract Chemical logging studies conducted at the Department of Energy's Raft River Geothermal Test Site in south central Idaho resulted in the development of a...

  5. Chemical Logging At Raft River Geothermal Area (1979) | Open...

    Open Energy Info (EERE)

    Raft River Geothermal Area (1979) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Chemical Logging At Raft River Geothermal Area (1979)...

  6. Acoustic Logs At Raft River Geothermal Area (1979) | Open Energy...

    Open Energy Info (EERE)

    Raft River Geothermal Area (1979) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Acoustic Logs At Raft River Geothermal Area (1979) Exploration...

  7. Selecting The Optimal Logging Suite For Geothermal Reservoir...

    Open Energy Info (EERE)

    and tensile wall fractures, and were adequate to detect stratigraphic features. Density, photo-electric factor (PEF), neutron, and gamma ray (GR) logs provided sufficient...

  8. Density Log At Valles Caldera - Redondo Geothermal Area (Rowley...

    Open Energy Info (EERE)

    Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Density Log At Valles Caldera - Redondo Geothermal Area (Rowley, Et Al., 1987) Exploration...

  9. Density Log At Valles Caldera - Redondo Geothermal Area (Wilt...

    Open Energy Info (EERE)

    Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Density Log At Valles Caldera - Redondo Geothermal Area (Wilt & Haar, 1986) Exploration...

  10. Energy Efficiency in Log Homes | Department of Energy

    Office of Environmental Management (EM)

    or purchasing a manufactured log home, you should consider several factors related to energy efficiency. The R-Value of Wood A material's thermal resistance or resistance to...

  11. Acoustic Logs At Alum Area (Moos & Ronne, 2010) | Open Energy...

    Open Energy Info (EERE)

    tensile wall fractures, and were adequate to detect stratigraphic features. References Daniel Moos, Joel Ronne (2010) Selecting The Optimal Logging Suite For Geothermal Reservoir...

  12. Pressure Temperature Log At Colrado Area (DOE GTP) | Open Energy...

    Open Energy Info (EERE)

    Colrado Area (DOE GTP) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Pressure Temperature Log At Colrado Area (DOE GTP) Exploration Activity...

  13. Pressure Temperature Log At Alum Area (DOE GTP) | Open Energy...

    Open Energy Info (EERE)

    Alum Area (DOE GTP) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Pressure Temperature Log At Alum Area (DOE GTP) Exploration Activity Details...

  14. FMI Log At Maui Area (DOE GTP) | Open Energy Information

    Open Energy Info (EERE)

    Maui Area (DOE GTP) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: FMI Log At Maui Area (DOE GTP) Exploration Activity Details Location Maui...

  15. Pressure Temperature Log At Mccoy Geothermal Area (DOE GTP) ...

    Open Energy Info (EERE)

    Mccoy Geothermal Area (DOE GTP) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Pressure Temperature Log At Mccoy Geothermal Area (DOE GTP)...

  16. FMI Log At Wister Area (DOE GTP) | Open Energy Information

    Open Energy Info (EERE)

    Wister Area (DOE GTP) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: FMI Log At Wister Area (DOE GTP) Exploration Activity Details Location...

  17. Pressure Temperature Log At Wister Area (DOE GTP) | Open Energy...

    Open Energy Info (EERE)

    Wister Area (DOE GTP) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Pressure Temperature Log At Wister Area (DOE GTP) Exploration Activity...

  18. Pressure Temperature Log At Maui Area (DOE GTP) | Open Energy...

    Open Energy Info (EERE)

    Maui Area (DOE GTP) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Pressure Temperature Log At Maui Area (DOE GTP) Exploration Activity Details...

  19. Well Log Data At North Brawley Geothermal Area (Matlick & Jayne...

    Open Energy Info (EERE)

    to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Well Log Data At North Brawley Geothermal Area (Matlick & Jayne, 2008) Exploration Activity Details...

  20. Well Log Data At North Brawley Geothermal Area (Edmunds & W....

    Open Energy Info (EERE)

    to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Well Log Data At North Brawley Geothermal Area (Edmunds & W., 1977) Exploration Activity Details...

  1. Well Log Data At Blue Mountain Geothermal Area (Fairbank & Niggemann...

    Open Energy Info (EERE)

    to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Well Log Data At Blue Mountain Geothermal Area (Fairbank & Niggemann, 2004) Exploration Activity...

  2. Signatures in flowing fluid electric conductivity logs (Journal...

    Office of Scientific and Technical Information (OSTI)

    including analysis of natural regional flowin the permeable layer. A numerical model simulates flow and transport inthe wellbore during flowing FEC logging, and fracture ...

  3. Gamma Log At Coso Geothermal Area (1977) | Open Energy Information

    Open Energy Info (EERE)

    Coso Geothermal Area (1977) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Gamma Log At Coso Geothermal Area (1977) Exploration Activity Details...

  4. Acoustic Logs At Coso Geothermal Area (1977) | Open Energy Information

    Open Energy Info (EERE)

    1977) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Acoustic Logs At Coso Geothermal Area (1977) Exploration Activity Details Location Coso...

  5. Neutron Log At Coso Geothermal Area (1977) | Open Energy Information

    Open Energy Info (EERE)

    Coso Geothermal Area (1977) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Neutron Log At Coso Geothermal Area (1977) Exploration Activity...

  6. Method for determining formation quality factor from well log...

    Office of Scientific and Technical Information (OSTI)

    and its application to seismic reservoir characterization Citation Details In-Document Search Title: Method for determining formation quality factor from well log data and its ...

  7. Pressure Temperature Log At Fish Lake Valley Area (DOE GTP) ...

    Open Energy Info (EERE)

    Fish Lake Valley Area (DOE GTP) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Pressure Temperature Log At Fish Lake Valley Area (DOE GTP)...

  8. Fluid-Rock Characterization and Interactions in NMR Well Logging

    SciTech Connect (OSTI)

    Hirasaki, George J.; Mohanty, Kishore, K.

    2001-07-13

    The objective of this project is to characterize the fluid properties and fluid-rock interactions that are needed for formation evaluation by NMR well logging. This is the first annual progress report submitted to the DOE. It reports on the work completed during the reporting period even if it may have started before this period. This project is a partnership between Professor George J. Hirasaki at Rice University and Professor Kishore Mohanty at University of Houston. In addition to the DOE, this project is supported by a consortium of oil companies and service companies. The fluid properties characterization has emphasized the departure of live oils from correlations based on dead oils. Also, asphaltic components can result in a difference between the T1 and T2 relaxation time distributions as well as reduce the hydrogen index. The fluid rock characterizations that are reported here are the effects of wettability and internal magnetic field gradients. A pore reconstruction method ha s been developed to recreate three-dimensional porous media from two-dimensional images that reproduce some of their key statistical properties. A Monte Carlo simulation technique has been developed to calculate the magnetization decay in fluid saturated porous media given their pore structure.

  9. Proceedings of the second PFN uranium logging seminar

    SciTech Connect (OSTI)

    Not Available

    1983-01-01

    The Prompt Fission Neutron (PFN) uranium logging system developed by Sandia National Laboratories for the US Department of Energy is described in some detail in papers by the staff that was involved in the final phase of the development project, and by others associated with the project as users of the logging probe or builders of some of the probe hardware. Descriptions are provided of the probe's electronic circuits, the uphole instrumentation, the log interpretation technique, field experience, neutron detection hardware, neutron generator design, life-test results, and observations by Bendix Field Engineering Corporation personnel regarding the use of the probe and its results.

  10. Geothermal well log interpretation state of the art. Final report

    SciTech Connect (OSTI)

    Sanyal, S.K.; Wells, L.E.; Bickham, R.E.

    1980-01-01

    An in-depth study of the state of the art in Geothermal Well Log Interpretation has been made encompassing case histories, technical papers, computerized literature searches, and actual processing of geothermal wells from New Mexico, Idaho, and California. A classification scheme of geothermal reservoir types was defined which distinguishes fluid phase and temperature, lithology, geologic province, pore geometry, salinity, and fluid chemistry. Major deficiencies of Geothermal Well Log Interpretation are defined and discussed with recommendations of possible solutions or research for solutions. The Geothermal Well Log Interpretation study and report has concentrated primarily on Western US reservoirs. Geopressured geothermal reservoirs are not considered.

  11. Connect & Log In | Argonne Leadership Computing Facility

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Account Information Accounts and Access FAQ Connect & Log In Using CRYPTOCards Disk Space Quota Management Allocations Mira/Cetus/Vesta Cooley Policies Documentation Feedback Please provide feedback to help guide us as we continue to build documentation for our new computing resource. [Feedback Form] Connect & Log In Users log into ALCF resources via ssh. ssh mira.alcf.anl.gov -l <username> Resources that are accessible via ssh are vesta.alcf.anl.gov, mira.alcf.anl.gov,

  12. NMOCD - Form G-105 - Geothermal Resources Well Log | Open Energy...

    Open Energy Info (EERE)

    Jump to: navigation, search OpenEI Reference LibraryAdd to library General: NMOCD - Form G-105 - Geothermal Resources Well Log Author State of New Mexico Energy and Minerals...

  13. JOBAID-LOGGING IN TO THE OLC LEARNING SYSTEM

    Broader source: Energy.gov [DOE]

    In this job aid you will Log In to the system, Retrieve Forgotten Password and/or User ID, and Use the LMS Help System built into the application.

  14. Efficiently log and perforate 60 + wells with coiled tubing

    SciTech Connect (OSTI)

    Fertl, W.H.; Hotz, R.F.

    1987-07-01

    In today's petroleum industry, more and more emphasis is being placed on logging and completion techniques for highly deviated (extended-reach) and horizontal boreholes. This is the result of cost-effective development of oil and gas via: a minimum number of production platforms on large structures, incremental but marginal reserves in outlying and/or small fault blocks, shallow reservoirs in deep offshore waters, and significant hydrocarbon accumulations in environmentally sensitive and/or restrictive areas, e.g., perma-frost, urban areas, etc. The major challenge in logging such high-angle, extended-reach, and also horizontal boreholes is guiding the logging tool string to the bottom of the wellbore. In the horizontal portion of a borehole, the use of coiled tubing has proven successful in ''pushing'' the logging instrumentation toward the bottom (end) of the borehole.

  15. Long Valley Caldera Field Trip Log | Open Energy Information

    Open Energy Info (EERE)

    to library Conference Paper: Long Valley Caldera Field Trip Log Abstract NA Authors Gene A. Suemnicht and Bastien Poux Conference NGA Long Valley Field Trip, July 5-7, 2012;...

  16. Fluid-Rock Characterization and Interactions in NMR Well Logging

    SciTech Connect (OSTI)

    Hirasaki, George J.; Mohanty, Kishore K.

    2003-02-10

    The objective of this project was to characterize the fluid properties and fluid-rock interactions which are needed for formation evaluation by NMR well logging. NMR well logging is finding wide use in formation evaluation. The formation parameters commonly estimated were porosity, permeability, and capillary bound water. Special cases include estimation of oil viscosity, residual oil saturation, location of oil/water contact, and interpretation on whether the hydrocarbon is oil or gas.

  17. Fluid-Rock Characterization and Interactions in NMR Well Logging

    SciTech Connect (OSTI)

    Hirasaki, George J.; Mohanty, Kishore K.

    2003-02-10

    The objective of this project was to characterize the fluid properties and fluid-rock interactions that are needed for formation evaluation by NMR well logging. The advances made in the understanding of NMR fluid properties are summarized in a chapter written for an AAPG book on NMR well logging. This includes live oils, viscous oils, natural gas mixtures, and the relation between relaxation time and diffusivity.

  18. Evaluation of Emerging Technology for Geothermal Drilling and Logging

    Broader source: Energy.gov (indexed) [DOE]

    Applications | Department of Energy Evaluation of Emerging Technology for Geothermal Drilling and Logging Applications presentation at the April 2013 peer review meeting held in Denver, Colorado. PDF icon sandia_evaluation_drilling_tech_peer2013.pdf More Documents & Publications Evaluation of Emerging Technology for Geothermal Drilling and Logging Applications Technology Development and Field Trials of EGS Drilling Systems GEA Geothermal Summit Presentation … Lauren Boyd

  19. Data Compendium for the Logging Test Pits at the ERDA Grand Junction...

    Energy Savers [EERE]

    Data Compendium for the Logging Test Pits at the ERDA Grand Junction Compound (December 1975) Data Compendium for the Logging Test Pits at the ERDA Grand Junction Compound ...

  20. A Model for Water Factor Measurements With Fission-Neutron Logging...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Grade Assignments for Models Used for Calibration of Gross-Count Gamma-Ray Logging Systems (December 1983) Logging Calibration Models for Fission Neutron Sondes (September 1981)

  1. Neutron Log At Alum Area (Moos & Ronne, 2010) | Open Energy Informatio...

    Open Energy Info (EERE)

    Technique Neutron Log Activity Date Usefulness useful DOE-funding Unknown Notes Density, photo-electric factor (PEF), neutron, and gamma ray (GR) logs provided sufficient...

  2. Gamma Log At Alum Area (Moos & Ronne, 2010) | Open Energy Information

    Open Energy Info (EERE)

    Technique Gamma Log Activity Date Usefulness useful DOE-funding Unknown Notes Density, photo-electric factor (PEF), neutron, and gamma ray (GR) logs provided sufficient...

  3. Technical evaluation of software for gamma-ray logging system

    SciTech Connect (OSTI)

    Stromswold, D.C.

    1994-05-01

    This report contains results of a technical review of software, identified as LGCALC, that processes data collected by a high-resolution gamma-ray borehole logging system. The software presently operates within Westinghouse Hanford Company, Department of Geosciences, to process data collected by the Radionuclide Logging System. The software has been reviewed for its suitability for processing data to be collected by new high-resolution gamma-ray logging trucks scheduled to begin operational tests within Westinghouse Tank Waste Remediation Systems during 1994. Examination of the program code and hands-on operational tests have shown that this software is suitable for its intended use of processing high-resolution gamma-ray data obtained from borehole logging. Most of the code requires no changes, but in a few limited cases, suggestions have been made to correct errors or improve operation. Section 4 describes these changes. The technical review has confirmed the appropriateness, correctness, completeness, and coding accuracy of algorithms used to process spectral gamma-ray data, leading to a calculation of subsurface radionuclide contaminants. Running the program with test data from calibration models has confirmed that the program operates correctly. Comparisons with hand calculations have shown the correctness of the output from the program, based on known input data. Section 3 describes these tests. The recommended action is to make the near term programming changes suggested in Section 4.1 and then use the LGCALC analysis program with the new high-resolution logging systems once they have been properly calibrated.

  4. Logging with coiled tubing less effective than with drill pipe

    SciTech Connect (OSTI)

    Van Den Bosch, R. )

    1994-01-31

    Coiled tubing offered neither economic nor operational advantages over drill pipe for conveying logging tools in open hole shallow horizontal wells in Germany. In the past 2 years, Mobil Erdgas-Erdoel GMbH (MEEG) participated in completing eight shallow horizontal wells. These were medium-to-short radius wells at measured depths of between 850 and 2,000 m. The average horizontal section was 350 m. The logging tools were conveyed by coiled tubing or drill pipe. MEEG attempted to log five wells with coiled tubing-conveyed tools, four with 1 1/2-in. tubing. Total depth was reached reliably in only one well, the shallowest and with the shortest horizontal section. Simulation programs were unreliable for calculating the downhole forces of the coil/tool combination or predicting possible helical lockups. In wells with drill pipe-conveyed logs, the tool combination could always be pushed to total depth, and the operations were generally faster and cost less than logging with coiled tubing. Also, drill pipe allowed longer and heavier tool strings. For reliable operations, coiled tubing needs to be more rigid, rig-up/rig-down times need to be improved, and the simulation programs must be more reliable for predicting downhole lock-up.

  5. Appendix A Lithologic and Monitor Well Completion Logs

    Office of Legacy Management (LM)

    A Lithologic and Monitor Well Completion Logs This page intentionally left blank WELL INSTALLATION BLANK CASING: 1.25 in. Stainless Steel 0.0 to 0.35 METHOD WELL SCREEN: 1.25 in. Stainless Steel 0.35 to 3.27 DATE DEVELOPED SUMPIEND CAP: 1.25 in. Stainless Steel 3.27 to 3.58 WATER LEVEL (FT BGS) SURFACE SEAL: LOGGED BY P. McKenzie REMARKS Drillers hit water at 5 fl: well point removed. LITHOLOGIC DESCRIPTION LOCATION SHIPROCK, NM SURFACE ELEV. ( FT NGVD) 4890.00 SITE SHIPROCK TOP OF CASING (FT)

  6. Dual-cone double-helical downhole logging device

    DOE Patents [OSTI]

    Yu, Jiunn S. (Albuquerque, NM)

    1984-01-01

    A broadband downhole logging device includes a double-helix coil wrapped over a dielectric support and surrounded by a dielectric shield. The device may also include a second coil longitudinally aligned with a first coil and enclosed within the same shield for measuring magnetic permeability of downhole formations and six additional coils for accurately determining downhole parameters.

  7. Fluid-Rock Characterization and Interactions in NMR Well Logging

    SciTech Connect (OSTI)

    George J. Hirasaki; Kishore K. Mohanty

    2005-09-05

    The objective of this report is to characterize the fluid properties and fluid-rock interactions that are needed for formation evaluation by NMR well logging. The advances made in the understanding of NMR fluid properties are summarized in a chapter written for an AAPG book on NMR well logging. This includes live oils, viscous oils, natural gas mixtures, and the relation between relaxation time and diffusivity. Oil based drilling fluids can have an adverse effect on NMR well logging if it alters the wettability of the formation. The effect of various surfactants on wettability and surface relaxivity are evaluated for silica sand. The relation between the relaxation time and diffusivity distinguishes the response of brine, oil, and gas in a NMR well log. A new NMR pulse sequence in the presence of a field gradient and a new inversion technique enables the T{sub 2} and diffusivity distributions to be displayed as a two-dimensional map. The objectives of pore morphology and rock characterization are to identify vug connectivity by using X-ray CT scan, and to improve NMR permeability correlation. Improved estimation of permeability from NMR response is possible by using estimated tortuosity as a parameter to interpolate between two existing permeability models.

  8. Photoneutron logging system for direct uranium ore-grade determination

    SciTech Connect (OSTI)

    Baker, M.P.; Marks, T.

    1982-06-01

    A prototype photoneutron probe for direct uranium assay in exploratory boreholes has been built and field tested. An approx. 10-Ci /sup 124/Sb gamma-ray source together with a beryllium converter is used to produce neutrons that diffuse into the surrounding formation and cause fissions in any /sup 235/U present. The fission neutrons that return to the probe are energy analyzed and counted by a high-pressure helium detector, thus indicating the concentration of uranium. The response of the probe was measured in concrete models at the US Department of Energy (Grand Junction, Colorado) calibration facility and found to be approx. 35 counts/s for an 1% U/sub 3/O/sub 8/ concentration in an 11.4-cm-diam water-filled borehole (4.5 in.). The response is linear up to a concentration of at least 0.25% by weight U/sub 3/O/sub 8/. Effects resulting from changes in formation density, porosity, and neutron absorber content were also quantified, as well as the tool response as a function of borehole diameter and fluid. A logging vehicle was outfitted, and the photoneutron-based logging system was field tested at an exploration site near Canon City, Colorado. Logging data obtained in several open holes at this site are presented and compared to core chemical analyses and results obtained in the same holes using other logging methods. In about 1 month of field testing, the photoneutron-based uranium exploration system has proved to be simple to use and very reliable. 22 figures, 12 tables.

  9. NREL: National Residential Efficiency Measures Database - Change Log

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    History Change Log History Here you can view a list of changes to the National Residential Efficiency Measures Database. Version Date Description v3.0.0 3/21/13 Public Release v2.0.0 11/1/10 Public Release v1.0.0 2/26/10 Public Release v1.0.0Beta 2/18/10 DOE Lab Review

  10. Cross-Dipole Acoustic Log | Open Energy Information

    Open Energy Info (EERE)

    Sonic Imager Internet. 2013. cited 20131010. Available from: http:www.slb.comservicescharacterizationgeomechanicswirelinedipoleshearsonicimager.aspx ...

  11. Calibration of NMR well logs from carbonate reservoirs with laboratory NMR measurements and μXRCT

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Mason, Harris E.; Smith, Megan M.; Hao, Yue; Carroll, Susan A.

    2014-12-31

    The use of nuclear magnetic resonance (NMR) well log data has the potential to provide in-situ porosity, pore size distributions, and permeability of target carbonate CO₂ storage reservoirs. However, these methods which have been successfully applied to sandstones have yet to be completely validated for carbonate reservoirs. Here, we have taken an approach to validate NMR measurements of carbonate rock cores with independent measurements of permeability and pore surface area to volume (S/V) distributions using differential pressure measurements and micro X-ray computed tomography (μXRCT) imaging methods, respectively. We observe that using standard methods for determining permeability from NMR data incorrectlymore » predicts these values by orders of magnitude. However, we do observe promise that NMR measurements provide reasonable estimates of pore S/V distributions, and with further independent measurements of the carbonate rock properties that universally applicable relationships between NMR measured properties may be developed for in-situ well logging applications of carbonate reservoirs.« less

  12. AmeriFlux BR-Sa3 Santarem-Km83-Logged Forest

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Goulden, Mike [University of California - Irvine

    2016-01-01

    This is the AmeriFlux version of the carbon flux data for the site BR-Sa3 Santarem-Km83-Logged Forest. Site Description - Cleared forest. Logged site is near km 83 along BR-183.

  13. E-print Network Web Log News: Research Communications for Scientists...

    Office of Scientific and Technical Information (OSTI)

    Description This Web Log provides the latest information about changes to E-print Network ... questions, concerns and other input by using the Contact Us page. Web Log Archive

  14. High voltage supply for neutron tubes in well logging applications

    DOE Patents [OSTI]

    Humphreys, D. Russell

    1989-01-01

    A high voltage supply is provided for a neutron tube used in well logging. The "biased pulse" supply of the invention combines DC and "full pulse" techniques and produces a target voltage comprising a substantial negative DC bias component on which is superimposed a pulse whose negative peak provides the desired negative voltage level for the neutron tube. The target voltage is preferably generated using voltage doubling techniques and employing a voltage source which generates bipolar pulse pairs having an amplitude corresponding to the DC bias level.

  15. Abbreviated Total-Count Logging Procedures for Use in Remedial Action

    Energy Savers [EERE]

    (December 1982) | Department of Energy Abbreviated Total-Count Logging Procedures for Use in Remedial Action (December 1982) Abbreviated Total-Count Logging Procedures for Use in Remedial Action (December 1982) Abbreviated Total-Count Logging Procedures for Use in Remedial Action (December 1982) PDF icon Abbreviated Total-Count Logging Procedures for Use in Remedial Action (December 1982) More Documents & Publications Field Calibration Facilities for Environmental Measurement of Radium,

  16. Logging into Deltek Time & Expense (T&E) | The Ames Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Logging into Deltek Time & Expense (T&E) Document Number: NA Effective Date: 07/2014

  17. Acoustic Logs At Steamboat Springs Area (Combs, Et Al., 1999...

    Open Energy Info (EERE)

    acoustic borehole televiewer (BHTV) yielded wellbore images down to 520';and a Sandia memory tool gave pressuretemperature data for a shut-in test at the end of the project....

  18. Nonprofit Organizations: Have Your Los Alamos Employees/Retirees Log Hours

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    in VolunteerMatch Nonprofit Organizations: Have Your Los Alamos Employees/Retirees Log Hours in VolunteerMatch Community Connections: Your link to news and opportunities from Los Alamos National Laboratory Latest Issue:May 2016 all issues All Issues » submit Nonprofit Organizations: Have Your Los Alamos Employees/Retirees Log Hours in VolunteerMatch Lab employees and retirees should log their VolunteerMatch hours to benefit local nonprofits. March 1, 2013 Volunteers help fill sandbags

  19. Calibration models for density borehole logging - construction report

    SciTech Connect (OSTI)

    Engelmann, R.E.; Lewis, R.E.; Stromswold, D.C.

    1995-10-01

    Two machined blocks of magnesium and aluminum alloys form the basis for Hanford`s density models. The blocks provide known densities of 1.780 {plus_minus} 0.002 g/cm{sup 3} and 2.804 {plus_minus} 0.002 g/cm{sup 3} for calibrating borehole logging tools that measure density based on gamma-ray scattering from a source in the tool. Each block is approximately 33 x 58 x 91 cm (13 x 23 x 36 in.) with cylindrical grooves cut into the sides of the blocks to hold steel casings of inner diameter 15 cm (6 in.) and 20 cm (8 in.). Spacers that can be inserted between the blocks and casings can create air gaps of thickness 0.64, 1.3, 1.9, and 2.5 cm (0.25, 0.5, 0.75 and 1.0 in.), simulating air gaps that can occur in actual wells from hole enlargements behind the casing.

  20. FMI Log At New River Area (DOE GTP) | Open Energy Information

    Open Energy Info (EERE)

    GTP) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: FMI Log At New River Area (DOE GTP) Exploration Activity Details Location New River Area...

  1. Well Log Techniques At Snake River Plain Region (DOE GTP) | Open...

    Open Energy Info (EERE)

    navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Well Log Techniques At Snake River Plain Region (DOE GTP) Exploration Activity Details Location Snake...

  2. Pressure Temperature Log At Soda Lake Area (DOE GTP) | Open Energy...

    Open Energy Info (EERE)

    navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Pressure Temperature Log At Soda Lake Area (DOE GTP) Exploration Activity Details Location Soda Lake...

  3. Well Log Data At Dixie Valley Geothermal Area (Barton, Et Al...

    Open Energy Info (EERE)

    Exploration Basis Well log data was used to investigate the relationship between permeability and the contemporary in situ stress field in the Dixie Valley Geothermal Reservoir....

  4. Well Log Data At Dixie Valley Geothermal Area (Mallan, Et Al...

    Open Energy Info (EERE)

    conducted to help characterize the geothermal reservoir by employing electromagnetic induction logging. The goal was to discern subsurface features that are useful in geothermal...

  5. Density Log at Gabbs Valley Area (DOE GTP) | Open Energy Information

    Open Energy Info (EERE)

    Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Density Log at Gabbs Valley Area (DOE GTP) Exploration Activity Details Location Gabbs Valley...

  6. Density Log at Fort Bliss Area (DOE GTP) | Open Energy Information

    Open Energy Info (EERE)

    Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Density Log at Fort Bliss Area (DOE GTP) Exploration Activity Details Location Fort Bliss...

  7. Density Log at Silver Peak Area (DOE GTP) | Open Energy Information

    Open Energy Info (EERE)

    Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Density Log at Silver Peak Area (DOE GTP) Exploration Activity Details Location Silver Peak...

  8. Density Log at Alum Area (Moos & Ronne, 2010) | Open Energy Informatio...

    Open Energy Info (EERE)

    Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Density Log at Alum Area (Moos & Ronne, 2010) Exploration Activity Details Location Alum...

  9. Cross-Dipole Acoustic Log At Alum Area (Moos & Ronne, 2010) ...

    Open Energy Info (EERE)

    oriented in the strike direction of the fault and of the dipping sediments. References Daniel Moos, Joel Ronne (2010) Selecting The Optimal Logging Suite For Geothermal Reservoir...

  10. FMI Log At Glass Buttes Area (DOE GTP) | Open Energy Information

    Open Energy Info (EERE)

    Glass Buttes Area (DOE GTP) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: FMI Log At Glass Buttes Area (DOE GTP) Exploration Activity Details...

  11. Gamma Log At Flint Geothermal Area (DOE GTP) | Open Energy Information

    Open Energy Info (EERE)

    Flint Geothermal Area (DOE GTP) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Gamma Log At Flint Geothermal Area (DOE GTP) Exploration Activity...

  12. Gamma Log At Silver Peak Area (DOE GTP) | Open Energy Information

    Open Energy Info (EERE)

    Silver Peak Area (DOE GTP) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Gamma Log At Silver Peak Area (DOE GTP) Exploration Activity Details...

  13. Resistivity Log At Fort Bliss Area (DOE GTP) | Open Energy Information

    Open Energy Info (EERE)

    DOE GTP) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Resistivity Log At Fort Bliss Area (DOE GTP) Exploration Activity Details Location Fort...

  14. Neutron Log At Silver Peak Area (DOE GTP) | Open Energy Information

    Open Energy Info (EERE)

    Silver Peak Area (DOE GTP) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Neutron Log At Silver Peak Area (DOE GTP) Exploration Activity Details...

  15. Acoustic Logs At The Needles Area (DOE GTP) | Open Energy Information

    Open Energy Info (EERE)

    The Needles Area (DOE GTP) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Acoustic Logs At The Needles Area (DOE GTP) Exploration Activity...

  16. Resistivity Log At The Needles Area (DOE GTP) | Open Energy Informatio...

    Open Energy Info (EERE)

    The Needles Area (DOE GTP) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Resistivity Log At The Needles Area (DOE GTP) Exploration Activity...

  17. Resistivity Log At Fort Bliss Area (Combs, Et Al., 1999) | Open...

    Open Energy Info (EERE)

    well. A suite of geophysical logs (gamma ray, neutron, sonic, and resistivity) was also run after completion of drilling. References Jim Combs, John T. Finger, Colin Goranson,...

  18. Gamma Log At Fort Bliss Area (Combs, Et Al., 1999) | Open Energy...

    Open Energy Info (EERE)

    well. A suite of geophysical logs (gamma ray, neutron, sonic, and resistivity) was also run after completion of drilling. References Jim Combs, John T. Finger, Colin Goranson,...

  19. Neutron Log At Fort Bliss Area (Combs, Et Al., 1999) | Open Energy...

    Open Energy Info (EERE)

    well. A suite of geophysical logs (gamma ray, neutron, sonic, and resistivity) was also run after completion of drilling. References Jim Combs, John T. Finger, Colin Goranson,...

  20. Density Log at Fish Lake Valley Area (DOE GTP) | Open Energy...

    Open Energy Info (EERE)

    Fish Lake Valley Area (DOE GTP) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Density Log at Fish Lake Valley Area (DOE GTP) Exploration...

  1. Resistivity Log At Fish Lake Valley Area (DOE GTP) | Open Energy...

    Open Energy Info (EERE)

    Fish Lake Valley Area (DOE GTP) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Resistivity Log At Fish Lake Valley Area (DOE GTP) Exploration...

  2. Stochastic Inversion of InSAR Data to Assess the Probability of Pressure Penetration into the Lower Caprock at In Salah

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Ramirez, Abelardo; Foxall, William

    2014-05-28

    Stochastic inversions of InSAR data were carried out to assess the probability that pressure perturbations resulting from CO2 injection into well KB-502 at In Salah penetrated into the lower caprock seal above the reservoir. Inversions of synthetic data were employed to evaluate the factors that affect the vertical resolution of overpressure distributions, and to assess the impact of various sources of uncertainty in prior constraints on inverse solutions. These include alternative pressure-driven deformation modes within reservoir and caprock, the geometry of a sub-vertical fracture zone in the caprock identified in previous studies, and imperfect estimates of the rock mechanical properties.more » Inversions of field data indicate that there is a high probability that a pressure perturbation during the first phase of injection extended upwards along the fracture zone ~ 150 m above the reservoir, and less than 50% probability that it reached the Hot Shale unit at 1500 m depth. Within the uncertainty bounds considered, it was concluded that it is very unlikely that the pressure perturbation approached within 150 m of the top of the lower caprock at the Hercynian Unconformity. The results are consistent with previous deterministic inversion and forward modeling studies.« less

  3. Stochastic Inversion of InSAR Data to Assess the Probability of Pressure Penetration into the Lower Caprock at In Salah

    SciTech Connect (OSTI)

    Ramirez, Abelardo; Foxall, William

    2014-05-28

    Stochastic inversions of InSAR data were carried out to assess the probability that pressure perturbations resulting from CO2 injection into well KB-502 at In Salah penetrated into the lower caprock seal above the reservoir. Inversions of synthetic data were employed to evaluate the factors that affect the vertical resolution of overpressure distributions, and to assess the impact of various sources of uncertainty in prior constraints on inverse solutions. These include alternative pressure-driven deformation modes within reservoir and caprock, the geometry of a sub-vertical fracture zone in the caprock identified in previous studies, and imperfect estimates of the rock mechanical properties. Inversions of field data indicate that there is a high probability that a pressure perturbation during the first phase of injection extended upwards along the fracture zone ~ 150 m above the reservoir, and less than 50% probability that it reached the Hot Shale unit at 1500 m depth. Within the uncertainty bounds considered, it was concluded that it is very unlikely that the pressure perturbation approached within 150 m of the top of the lower caprock at the Hercynian Unconformity. The results are consistent with previous deterministic inversion and forward modeling studies.

  4. TMACS test procedure TP005: Sensor configuration, logging, and data conversion. Revision 4

    SciTech Connect (OSTI)

    Washburn, S.J.

    1994-08-25

    The TMACS Software Project Test Procedures translate the project`s acceptance criteria into test steps. Software releases are certified when the affected Test Procedures are successfully performed and the customers authorize installation of these changes. This Test Procedure addresses the sensor configuration, conversion and logging requirements of the TMACS. The features to be tested are as follows: sensor configuration data; conversion of continuous sensor data to engineering units; conversion of digital data to discrete states; discrete sensor data logging; and continuous sensor data logging.

  5. Property:Building/SPPurchasedEngyNrmlYrMwhYrLogs | Open Energy...

    Open Energy Info (EERE)

    Datasets Community Login | Sign Up Search Property Edit with form History Property:BuildingSPPurchasedEngyNrmlYrMwhYrLogs Jump to: navigation, search This is a property of type...

  6. Temperatures and Natural Gamma-Ray Logs Obtained in 1986 from...

    Open Energy Info (EERE)

    of the formation to absorb injected fluid after the well was completed. Changes in temperature logs run in July and September appear to result from fluid loss to the...

  7. Lithology and well log study of Campbell E-2 geothermal test...

    Open Energy Info (EERE)

    well log study of Campbell E-2 geothermal test well, Humboldt House geothermal prospect, Pershing County, Nevada Jump to: navigation, search OpenEI Reference LibraryAdd to library...

  8. Method for determining formation quality factor from well log data and its

    Office of Scientific and Technical Information (OSTI)

    application to seismic reservoir characterization (Patent) | SciTech Connect Patent: Method for determining formation quality factor from well log data and its application to seismic reservoir characterization Citation Details In-Document Search Title: Method for determining formation quality factor from well log data and its application to seismic reservoir characterization A method for seismic characterization of subsurface Earth formations includes determining at least one of

  9. Method for determining formation quality factor from well log data and its

    Office of Scientific and Technical Information (OSTI)

    application to seismic reservoir characterization (Patent) | SciTech Connect Patent: Method for determining formation quality factor from well log data and its application to seismic reservoir characterization Citation Details In-Document Search Title: Method for determining formation quality factor from well log data and its application to seismic reservoir characterization × You are accessing a document from the Department of Energy's (DOE) SciTech Connect. This site is a product of DOE's

  10. Evaluation of Simple Causal Message Logging for Large-Scale Fault Tolerant HPC Systems

    SciTech Connect (OSTI)

    Bronevetsky, G; Meneses, E; Kale, L V

    2011-02-25

    The era of petascale computing brought machines with hundreds of thousands of processors. The next generation of exascale supercomputers will make available clusters with millions of processors. In those machines, mean time between failures will range from a few minutes to few tens of minutes, making the crash of a processor the common case, instead of a rarity. Parallel applications running on those large machines will need to simultaneously survive crashes and maintain high productivity. To achieve that, fault tolerance techniques will have to go beyond checkpoint/restart, which requires all processors to roll back in case of a failure. Incorporating some form of message logging will provide a framework where only a subset of processors are rolled back after a crash. In this paper, we discuss why a simple causal message logging protocol seems a promising alternative to provide fault tolerance in large supercomputers. As opposed to pessimistic message logging, it has low latency overhead, especially in collective communication operations. Besides, it saves messages when more than one thread is running per processor. Finally, we demonstrate that a simple causal message logging protocol has a faster recovery and a low performance penalty when compared to checkpoint/restart. Running NAS Parallel Benchmarks (CG, MG and BT) on 1024 processors, simple causal message logging has a latency overhead below 5%.

  11. Calibration models for measuring moisture in unsaturated formations by neutron logging

    SciTech Connect (OSTI)

    Engelman, R.E.; Lewis, R.E.; Stromswold, D.C.

    1995-10-01

    Calibration models containing known amounts of hydrogen have been constructed to simulate unsaturated earth formations for calibrating neutron well logging tools. The models are made of dry mixtures of hydrated alumina (Al(OH){sub 3}) with either silica sand (SiO{sub 2}) or aluminum oxide (Al{sub 2}O{sub 3}). Hydrogen in the hydrated alumina replaces the hydrogen in water for neutron scattering, making it possible to simulate partially saturated formations. The equivalent water contents for the models are 5%, 12%, 20%, and 40% by volume in seven tanks that have a diameter of 1.5 m and a height of 1.8 m. Steel casings of inside diameter 15.4 cm (for three models) and diameter 20.3 cm (for four models) allow logging tool access to simulate logging through cased boreholes.

  12. Borehole induction logging for the Dynamic Underground Stripping Project LLNL gasoline spill site

    SciTech Connect (OSTI)

    Boyd, S.; Newmark, R.; Wilt, M.

    1994-01-21

    Borehole induction logs were acquired for the purpose of characterizing subsurface physical properties and monitoring steam clean up activities at the Lawrence Livermore National Laboratory. This work was part of the Dynamic Underground Stripping Project`s demonstrated clean up of a gasoline spin. The site is composed of unconsolidated days, sands and gravels which contain gasoline both above and below the water table. Induction logs were used to characterize lithology, to provide ``ground truth`` resistivity values for electrical resistance tomography (ERT), and to monitor the movement of an underground steam plume used to heat the soil and drive volatile organic compounds (VOCs) to the extraction wells.

  13. Outage Log

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    10:00 - 16:50. No user impact was expected. These switches provide connectivity for the meta-data servers for homes, common, project, syscomm, dna and projectb. 111115 9:00...

  14. Log Summarization

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... Our longer term vision includes a web services front end to the anomaly detection ... calculation, as- suming that the average latency per call is just the inverse of ...

  15. Idaho National Laboratory PCB Annual Document Log and Annual Records Report for calendar year 2014

    SciTech Connect (OSTI)

    Layton, Deborah L.

    2015-06-01

    The requirements for the reporting of polychlorinated biphenyl (PCB)-related activities are found in 40 Code of Federal Regulations (CFR) 761 Subpart J, "General Records and Reports." The PCB Annual Document Log is a detailed record of the PCB waste handling activities at the facility. The facility must prepare it each year by July 1 and maintain it at the facility for at least 3 years after the facility ceases using or storing PCBs and PCB items. While submittal of the PCB Annual Document Log to the U.S. Environmental Protection Agency (EPA) is not required by regulation, EPA has verbally requested in telephone conversations that this report be submitted to them on an annual basis. The Annual Records are not required to be submitted to EPA and are not considered to be part of the Annual Document Log, but are included to provide the complete disposition history or status of all PCB activities during the year. The Annual Document Log section of this report (Section 2.0) meets the requirements of 40 CFR 761.180(a)(2), as applicable, while the Annual Records section (Section 3.0) meets the requirement of 40 CFR 761.180(a)(1).

  16. Correction of steel casing effect for density log using numerical and experimental methods in the slim borehole

    SciTech Connect (OSTI)

    Hwang, Seho; Shin, Jehyun; Kim, Jongman; Won, Byeongho

    2015-03-10

    Density log is widely applied for a variety of fields such as the petroleum exploration, mineral exploration, and geotechnical survey. The logging condition of density log is normally open holes but there are frequently cased boreholes. The primary calibration curve by slim hole logging manufacturer is normally the calibration curves for the variation of borehole diameter. In this study, we have performed the correction of steel casing effects using numerical and experimental methods. We have performed numerical modeling using the Monte Carlo N-Particle (MCNP) code based on Monte Carlo method, and field experimental method from open and cased hole log. In this study, we used the FDGS (Formation Density Gamma Sonde) for slim borehole with a 100 mCi 137Cs source, three inch borehole and steel casing. The casing effect between numerical and experimental method is well matched.

  17. Quantification of Wellbore Leakage Risk Using Non-destructive Borehole Logging Techniques

    SciTech Connect (OSTI)

    Duguid, Andrew; Butsch, Robert; Cary, J.; Celia, Michael; Chugunov, Nikita; Gasda, Sarah; Hovorka, Susan; Ramakrishnan, T. S.; Stamp, Vicki; Thingelstad, Rebecca; Wang, James

    2014-08-29

    Well integrity is important at all potential CCS locations and may play a crucial role establishing leakage risk in areas where there is a high density of existing wells that could be impacted by the storage operations including depleted petroleum fields where EOR or CCS will occur. To address a need for risk quantification methods that can be directly applied to individual wells using borehole logging tools a study was conducted using data from five wells in Wyoming. The objectives of the study were: Objective 1: Develop methods to establish the baseline flow parameters (porosity and permeability or mobility) from individual measurements of the material properties and defects in a well. Objective 2: Develop a correlation between field flow-property data and cement logs that can be used to establish the flow-properties of well materials and well features using cement mapping tools. Objective 3: Establish a method that uses the flow-property model (Objective 2) to analyze the statistical uncertainties associated with individual well leakage that can provide basis for uncertainty in risk calculations. The project objectives were met through the logging of five wells in Carbon and Natrona County Wyoming to collect data that was used to estimate individual and average well flow properties and model the results using ultrasonic data collected during the logging. Three of the five wells provided data on point and average flow properties for well annuli. Data from the other two wells were used to create models of cement permeability and test whether information collected in one well could be used to characterize another well. The results of the in-situ point measurements were confirmed by the lab measurements sidewall cores collected near the same depths Objective 1 was met using the data collected through logging, testing, and sampling. The methods were developed that can establish baseline flow parameters of wells by both point and average test methods. The methods to estimate the flow properties modeling of point pressure tests, modeling of vertical interference tests, and laboratory measurement of cased-hole sidewall cores The wells were in sufficiently good shape to allow the development of the characterization methods while still having enough defects to study differences in results as they relate to well integrity. Samples and tests analyzed from three of five wells studied in showed the cements were largely intact and had not degraded from exposure native brines. Log results taken in conjunction with the core measurements indicate that interfaces and/or problems with cement placement due to eccentering provide preferential flow paths for fluids, which can increase the effective permeability of the barrier several orders of magnitude above the permeability of intact cement. The results of the maps created using logging tools indicating that the cement condition and bond are generally good identify a need for more research to understand how logs can be used to predicteffective well permeabilities such as those measured by the VITs in this study.

  18. Log-ratio signal-processing technique for beam position monitors

    SciTech Connect (OSTI)

    Shafer, R.E.

    1993-01-01

    Two basic signal-processing techniques are presently in wide use for the processing of signals from beam position monitors (BPMs); difference-over-sum, and amplitude-modulation-to-phase-modulation (AM-PM) conversion. Difference-over-sum offers simplicity and low cost, but poor real-time normalized response and amplitude dynamic range. AM-PM offers fast real-time response and large dynamic range, but is costly and difficult to implement. Logarithmic-ratio processing, a technique using newly available inexpensive hybrid circuits, appears to offer the advantages of both, and the disadvantages of neither. This paper reviews the features techniques, and highlights the features of the log-ratio technique. Among the advantages of log-ratio is a beam-displacement response linearity that is superior to either difference-over-sum or AM-PM for circular-aperture BPMs.

  19. Log-ratio signal-processing technique for beam position monitors

    SciTech Connect (OSTI)

    Shafer, R.E.

    1993-02-01

    Two basic signal-processing techniques are presently in wide use for the processing of signals from beam position monitors (BPMs); difference-over-sum, and amplitude-modulation-to-phase-modulation (AM-PM) conversion. Difference-over-sum offers simplicity and low cost, but poor real-time normalized response and amplitude dynamic range. AM-PM offers fast real-time response and large dynamic range, but is costly and difficult to implement. Logarithmic-ratio processing, a technique using newly available inexpensive hybrid circuits, appears to offer the advantages of both, and the disadvantages of neither. This paper reviews the features techniques, and highlights the features of the log-ratio technique. Among the advantages of log-ratio is a beam-displacement response linearity that is superior to either difference-over-sum or AM-PM for circular-aperture BPMs.

  20. Evaluation of Non-Nuclear Techniques for Well Logging: Final Report

    SciTech Connect (OSTI)

    Bond, Leonard J.; Griffin, Jeffrey W.; Harris, R. V.; Denslow, Kayte M.; Moran, Traci L.

    2011-08-01

    The focus of this study is the understanding of the technical obstacles that hinder the replacement of and the disadvantages from the loss of extensive interpretation experience based on data accumulated with AmBe. Enhanced acoustic and electromagnetic sensing methods in combination with non-isotope-based well logging techniques have the potential to complement and/or replace existing isotope-based techniques, providing the opportunity to reduce oil industry dependence on isotopic sources such as AmBe.

  1. U-038: BIND 9 Resolver crashes after logging an error in query.c

    Broader source: Energy.gov [DOE]

    A remote server can cause the target connected client to crash. Organizations across the Internet are reporting crashes interrupting service on BIND 9 nameservers performing recursive queries. Affected servers crash after logging an error in query.c with the following message: "INSIST(! dns_rdataset_isassociated(sigrdataset))" Multiple versions are reported as being affected, including all currently supported release versions of ISC BIND 9. ISC is actively investigating the root cause and working to produce patches which avoid the crash.

  2. U-039: ISC Update: BIND 9 Resolver crashes after logging an error in query.c

    Broader source: Energy.gov [DOE]

    A remote server can cause the target connected client to crash. Organizations across the Internet are reporting crashes interrupting service on BIND 9 nameservers performing recursive queries. Affected servers crash after logging an error in query.c with the following message: "INSIST(! dns_rdataset_isassociated(sigrdataset))" Multiple versions are reported as being affected, including all currently supported release versions of ISC BIND 9. ISC is actively investigating the root cause and working to produce patches which avoid the crash.

  3. High-voltage supply for neutron tubes in well-logging applications

    DOE Patents [OSTI]

    Humphreys, D.R.

    1982-09-15

    A high voltage supply is provided for a neutron tube used in well logging. The biased pulse supply of the invention combines DC and full pulse techniques and produces a target voltage comprising a substantial negative DC bias component on which is superimposed a pulse whose negative peak provides the desired negative voltage level for the neutron tube. The target voltage is preferably generated using voltage doubling techniques and employing a voltage source which generates bipolar pulse pairs having an amplitude corresponding to the DC bias level.

  4. Method of assaying uranium with prompt fission and thermal neutron borehole logging adjusted by borehole physical characteristics. [Patient application

    DOE Patents [OSTI]

    Barnard, R.W.; Jensen, D.H.

    1980-11-05

    Uranium formations are assayed by prompt fission neutron logging techniques. The uranium in the formation is proportional to the ratio of epithermal counts to thermal or epithermal dieaway. Various calibration factors enhance the accuracy of the measurement.

  5. Method of assaying uranium with prompt fission and thermal neutron borehole logging adjusted by borehole physical characteristics

    DOE Patents [OSTI]

    Barnard, Ralston W. (Albuquerque, NM); Jensen, Dal H. (Albuquerque, NM)

    1982-01-01

    Uranium formations are assayed by prompt fission neutron logging techniques. The uranium in the formation is proportional to the ratio of epithermal counts to thermal or eqithermal dieaway. Various calibration factors enhance the accuracy of the measurement.

  6. Evaluation of Non-Nuclear Techniques for Well Logging: Technology Evaluation

    SciTech Connect (OSTI)

    Bond, Leonard J.; Denslow, Kayte M.; Griffin, Jeffrey W.; Dale, Gregory E.; Harris, Robert V.; Moran, Traci L.; Sheen, David M.; Schenkel, Thomas

    2010-11-01

    This report presents an initial review of the state-of-the-art nuclear and non-nuclear well logging methods and seeks to understand the technical and economic issues if AmBe, and potentially other isotope sources, are reduced or even eliminated in the oil-field services industry. Prior to considering alternative logging technologies, there is a definite need to open up discussions with industry regarding the feasibility and acceptability of source replacement. Industry views appear to range from those who see AmBe as vital and irreplaceable to those who believe that, with research and investment, it may be possible to transition to electronic neutron sources and employ combinations of non-nuclear technologies to acquire the desired petro-physical parameters. In one sense, the simple answer to the question as to whether petro-physical parameters can be sensed with technologies other than AmBe is probably "Yes". The challenges come when attention turns to record interpretation. The many decades of existing records form a very valuable proprietary resource, and the interpretation of subtle features contained in these records are of significant value to the oil-gas exploration community to correctly characterize a well. The demonstration of equivalence and correspondence/correlation between established and any new sensing modality, and correlations with historic records is critical to ensuring accurate data interpretation. Establishing the technical basis for such a demonstration represents a significant effort.

  7. The application of moment methods to the analysis of fluid electrical conductivity logs in boreholes

    SciTech Connect (OSTI)

    Loew, S. ); Tsang, Chin-Fu; Hale, F.V. ); Hufschmied, P. , Baden )

    1990-08-01

    This report is one of a series documenting the results of the Nagra-DOE Cooperative (NDC-I) research program in which the cooperating scientists explore the geological, geophysical, hydrological, geochemical, and structural effects anticipated from the use of a rock mass as a geologic repository for nuclear waste. Previous reports have presented a procedure for analyzing a time sequence of wellbore electric conductivity logs in order to obtain outflow parameters of fractures intercepted by the borehole, and a code, called BORE, used to simulate borehole fluid conductivity profiles given these parameters. The present report describes three new direct (not iterative) methods for analyzing a short time series of electric conductivity logs based on moment quantities of the individual outflow peaks and applies them to synthetic as well as to field data. The results of the methods discussed show promising results and are discussed in terms of their respective advantages and limitations. In particular it is shown that one of these methods, the so-called Partial Moment Method,'' is capable of reproducing packer test results from field experiments in the Leuggern deep well within a factor of three, which is below the range of what is recognized as the precision of packer tests themselves. Furthermore the new method is much quicker than the previously used iterative fitting procedure and is even capable of handling transient fracture outflow conditions. 20 refs., 11 figs., 10 tabs.

  8. Image Gallery

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Image Gallery News & Publications ESnet News Publications and Presentations Galleries Image Gallery Video Gallery ESnet Awards and Honors Contact Us Media Jon Bashor, ...

  9. Seismic reflection imaging at a Shallow Site

    SciTech Connect (OSTI)

    Milligan, P.; Rector, J.; Bainer, R.

    1997-01-01

    The objective of our studies was to determine the best seismic method to image these sediments, between the water table at 3 m depth to the basement at 35 m depth. Good cross-correlation between well logs and the seismic data was also desirable, and would facilitate the tracking of known lithological units away from the wells. For instance, known aquifer control boundaries may then be mapped out over the boundaries, and may be used in a joint inversion with reflectivity data and other non-seismic geophysical data to produce a 3-D image containing quantitative physical properties of the target area.

  10. Fracture mapping in geothermal fields with long-offset induction logging

    SciTech Connect (OSTI)

    Wilt, M.; Takasugi, Shinji; Uchida, Toshihiro; Kasameyer, P.; Lee, Ki Ha; Lippmann, M.

    1997-01-01

    The mapping of producing fractures in a geothermal field is an important technical objective in field development. Locating, orientating, and assessing producing fractures can guide drilling programs and optimize the placement of production and injection wells. A long-offset multicomponent borehole induction resistivity tool capable of surviving the high temperatures encountered in geothermal wells has recently been developed and tested in a high temperature environment. Several characteristics of this device make it ideal for detecting producing fractures. Whereas commercial induction logging devices have strong source-receiver separations of 1 m, this device has multiple sensors with separation of 8 m, allowing for deeper penetrations and the ability to straddle fracture-induced washout zones in boreholes. The three-component measurements also make it possible to map the strike and inclination of nearby fractures and other three-dimensional structures. This in turn allows for accurate projection of these structures into the space between wells.

  11. AVTA Federal Fleet PEV Readiness Data Logging and Characterization Study: Final Report

    SciTech Connect (OSTI)

    Schey, Stephen; Francfort, Jim

    2015-06-01

    Collect and evaluate data on federal fleet operations as part of the Advanced Vehicle Testing Activity’s Federal Fleet Vehicle Data Logging and Characterization Study. The Advanced Vehicle Testing Activity study seeks to collect and evaluate data to validate the utilization of advanced plug-in electric vehicle (PEV) transportation. This report summarizes the fleets studied to identify daily operational characteristics of select vehicles and report findings on vehicle and mission characterizations to support the successful introduction of PEVs into the agencies’ fleets. Individual observations of these selected vehicles provide the basis for recommendations related to electric vehicle adoption and whether a battery electric vehicle or plug-in hybrid electric vehicle (collectively referred to as PEVs) can fulfill the mission requirements.

  12. SU-C-BRD-03: Analysis of Accelerator Generated Text Logs for Preemptive Maintenance

    SciTech Connect (OSTI)

    Able, CM; Baydush, AH; Nguyen, C; Munley, MT; Gersh, J; Ndlovu, A; Rebo, I; Booth, J; Perez, M; Sintay, B

    2014-06-15

    Purpose: To develop a model to analyze medical accelerator generated parameter and performance data that will provide an early warning of performance degradation and impending component failure. Methods: A robust 6 MV VMAT quality assurance treatment delivery was used to test the constancy of accelerator performance. The generated text log files were decoded and analyzed using statistical process control (SPC) methodology. The text file data is a single snapshot of energy specific and overall systems parameters. A total of 36 system parameters were monitored which include RF generation, electron gun control, energy control, beam uniformity control, DC voltage generation, and cooling systems. The parameters were analyzed using Individual and Moving Range (I/MR) charts. The chart limits were calculated using a hybrid technique that included the use of the standard 3? limits and the parameter/system specification. Synthetic errors/changes were introduced to determine the initial effectiveness of I/MR charts in detecting relevant changes in operating parameters. The magnitude of the synthetic errors/changes was based on: the value of 1 standard deviation from the mean operating parameter of 483 TB systems, a small fraction (? 5%) of the operating range, or a fraction of the minor fault deviation. Results: There were 34 parameters in which synthetic errors were introduced. There were 2 parameters (radial position steering coil, and positive 24V DC) in which the errors did not exceed the limit of the I/MR chart. The I chart limit was exceeded for all of the remaining parameters (94.2%). The MR chart limit was exceeded in 29 of the 32 parameters (85.3%) in which the I chart limit was exceeded. Conclusion: Statistical process control I/MR evaluation of text log file parameters may be effective in providing an early warning of performance degradation or component failure for digital medical accelerator systems. Research is Supported by Varian Medical Systems, Inc.

  13. Log analysis of six boreholes in conjunction with geologic characterization above and on top of the Weeks Island salt dome

    SciTech Connect (OSTI)

    Sattler, A.R.

    1996-04-01

    Six boreholes were drilled during the geologic characterization and diagnostics of the Weeks Island sinkhole that is over the two-tiered salt mine which was converted for oil storage by the US Strategic Petroleum Reserve. These holes were drilled to provide for geologic characterization of the Weeks Island Salt Dome and its overburden in the immediate vicinity of the sinkhole (mainly through logs and core); to establish a crosswell configuration for seismic tomography; to establish locations for hydrocarbon detection and tracer injection; and to Provide direct observations of sinkhole geometry and material properties. Specific objectives of the logging program were to: (1) identify the top of and the physical state of the salt dome; (2) identify the water table; (3) obtain a relative salinity profile in the aquifer within the alluvium, which ranges from the water table directly to the top of the Weeks Island salt dome; and (4) identify a reflecting horizon seen on seismic profiles over this salt dome. Natural gamma, neutron, density, sonic, resistivity and caliper logs were run. Neutron and density logs were run from inside the well casing because of the extremely unstable condition of the deltaic alluvium overburden above the salt dome. The logging program provided important information about the salt dome and the overburden in that (1) the top of the salt dome was identified at {approximately}189 ft bgl (103 ft msl), and the top of the dome contains relatively few fractures; (2) the water table is approximately 1 ft msl, (3) this aquifer appears to become steadily more saline with depth; and (4) the water saturation of much of the alluvium over the salt dome is shown to be influenced by the prevalent heavy rainfall. This logging program, a part of the sinkhole diagnostics, provides unique information about this salt dome and the overburden.

  14. Image alignment

    DOE Patents [OSTI]

    Dowell, Larry Jonathan

    2014-04-22

    Disclosed is a method and device for aligning at least two digital images. An embodiment may use frequency-domain transforms of small tiles created from each image to identify substantially similar, "distinguishing" features within each of the images, and then align the images together based on the location of the distinguishing features. To accomplish this, an embodiment may create equal sized tile sub-images for each image. A "key" for each tile may be created by performing a frequency-domain transform calculation on each tile. A information-distance difference between each possible pair of tiles on each image may be calculated to identify distinguishing features. From analysis of the information-distance differences of the pairs of tiles, a subset of tiles with high discrimination metrics in relation to other tiles may be located for each image. The subset of distinguishing tiles for each image may then be compared to locate tiles with substantially similar keys and/or information-distance metrics to other tiles of other images. Once similar tiles are located for each image, the images may be aligned in relation to the identified similar tiles.

  15. Parameter estimation from flowing fluid temperature logging data in unsaturated fractured rock using multiphase inverse modeling

    SciTech Connect (OSTI)

    Mukhopadhyay, S.; Tsang, Y.; Finsterle, S.

    2009-01-15

    A simple conceptual model has been recently developed for analyzing pressure and temperature data from flowing fluid temperature logging (FFTL) in unsaturated fractured rock. Using this conceptual model, we developed an analytical solution for FFTL pressure response, and a semianalytical solution for FFTL temperature response. We also proposed a method for estimating fracture permeability from FFTL temperature data. The conceptual model was based on some simplifying assumptions, particularly that a single-phase airflow model was used. In this paper, we develop a more comprehensive numerical model of multiphase flow and heat transfer associated with FFTL. Using this numerical model, we perform a number of forward simulations to determine the parameters that have the strongest influence on the pressure and temperature response from FFTL. We then use the iTOUGH2 optimization code to estimate these most sensitive parameters through inverse modeling and to quantify the uncertainties associated with these estimated parameters. We conclude that FFTL can be utilized to determine permeability, porosity, and thermal conductivity of the fracture rock. Two other parameters, which are not properties of the fractured rock, have strong influence on FFTL response. These are pressure and temperature in the borehole that were at equilibrium with the fractured rock formation at the beginning of FFTL. We illustrate how these parameters can also be estimated from FFTL data.

  16. Shallow infiltration processes at Yucca Mountain, Nevada: Neutron logging data 1984--1993

    SciTech Connect (OSTI)

    Flint, L.E.; Flint, A.L.

    1995-12-31

    To determine site suitability of Yucca Mountain, Nevada, as a potential high-level radioactive waste repository, a study was devised to characterize net infiltration. This study involves a detailed data set produced from 99 neutron boreholes that consisted of volumetric water-content readings with depth from 1984 through 1993 at Yucca Mountain. Boreholes were drilled with minimal disturbance to the surrounding soil or rock in order to best represent field conditions. Boreholes were located in topographic positions representing infiltration zones identified as ridgetops, sideslopes, terraces, and active channels. Through careful field calibration, neutron moisture logs, collected on a monthly basis and representing most of the areal locations at Yucca Mountain, illustrated that the depth of penetration of seasonal moisture, important for escaping loss to evapotranspiration, was influenced by several factors. It was increased (1) by thin soil cover, especially in locations where thin soil is underlain by fractured bedrock; (2) on ridgetops; and (3) during the winter when evapotranspiration is low and runoff is less frequent. This data set helps to provide a seasonal and areal distribution of changes in volumetric water content with which to assess hydrologic processes contributing to net infiltration.

  17. Shallow infiltration processes at Yucca Mountain, Nevada - neutron logging data 1984-93

    SciTech Connect (OSTI)

    Flint, L.E.; Flint, A.L.

    1995-11-01

    To determine site suitability of Yucca Mountain, Nevada, as a potential high-level radioactive waste repository, a study was devised to characterize net infiltration. This study involves a detailed data set produced from 99 neutron boreholes that consisted of volumetric water-content readings with depth from 1984 through 1993 at Yucca Mountain. Boreholes were drilled with minimal disturbance to the surrounding soil or rock in order to best represent field conditions. Boreholes were located in topographic positions representing infiltration zones identified as ridge-tops, sideslopes, terraces, and active channels. Through careful field calibration, neutron moisture logs, collected on a monthly basis and representing most of the areal locations at Yucca Mountain, illustrated that the depth of penetration of seasonal moisture, important for escaping loss to evapotranspiration, was influenced by several factors. It was increased (1) by thin soil cover, especially in locations where thin soil is underlain by fractured bedrock; (2) on ridgetops; and (3) during the winter when evapotranspiration is low and runoff is less frequent. This data set helps to provide a seasonal and areal distribution of changes in volumetric water content with which to assess hydrologic processes contributing to net infiltration.

  18. Posterior propriety for hierarchical models with log-likelihoods that have norm bounds

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Michalak, Sarah E.; Morris, Carl N.

    2015-07-17

    Statisticians often use improper priors to express ignorance or to provide good frequency properties, requiring that posterior propriety be verified. Our paper addresses generalized linear mixed models, GLMMs, when Level I parameters have Normal distributions, with many commonly-used hyperpriors. It provides easy-to-verify sufficient posterior propriety conditions based on dimensions, matrix ranks, and exponentiated norm bounds, ENBs, for the Level I likelihood. Since many familiar likelihoods have ENBs, which is often verifiable via log-concavity and MLE finiteness, our novel use of ENBs permits unification of posterior propriety results and posterior MGF/moment results for many useful Level I distributions, including those commonlymore » used with multilevel generalized linear models, e.g., GLMMs and hierarchical generalized linear models, HGLMs. Furthermore, those who need to verify existence of posterior distributions or of posterior MGFs/moments for a multilevel generalized linear model given a proper or improper multivariate F prior as in Section 1 should find the required results in Sections 1 and 2 and Theorem 3 (GLMMs), Theorem 4 (HGLMs), or Theorem 5 (posterior MGFs/moments).« less

  19. Log analysis of six boreholes in conjunction with geologic characterization above and on top of the Weeks Island Salt Dome

    SciTech Connect (OSTI)

    Sattler, A.R.

    1996-06-01

    Six boreholes were drilled during the geologic characterization and diagnostics of the Weeks Island sinkhole that is over the two-tiered salt mine which was converted for oil storage by the U.S. Strategic Petroleum Reserve. These holes were drilled to provide for geologic characterization of the Weeks Island Salt Dome and its overburden in the immediate vicinity of the sinkhole (mainly through logs and core); to establish a crosswell configuration for seismic tomography; to establish locations for hydrocarbon detection and tracer injection; and to provide direct observations of sinkhole geometry and material properties. Specific objectives of the logging program were to: (1) identify the top of and the physical state of the salt dome; (2) identify the water table; (3) obtain a relative salinity profile in the aquifer within the alluvium, which ranges from the water table directly to the top of the Weeks Island salt dome; and (4) identify a reflecting horizon seen on seismic profiles over this salt dome. Natural gamma, neutron, density, sonic, resistivity and caliper logs were run.

  20. History Images

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    History Images Los Alamos History in Images Los Alamos has a proud history and heritage of almost 70 years of science and innovation. The people of the Laboratory work on advanced technologies to provide the best scientific and engineering solutions to many of the nation's most crucial security challenges. Click thumbnails to enlarge. Photos arranged by most recent first, horizontal formats before vertical. See Flickr for more sizes and details. Back in the day Back in the day LA bridge in Los

  1. Species characterization and responses of subcortical insects to trap-logs and ethanol in a hardwood biomass plantation: Subcortical insects in hardwood plantations

    SciTech Connect (OSTI)

    Coyle, David R.; Brissey, Courtney L.; Gandhi, Kamal J. K.

    2015-01-02

    1. We characterized subcortical insect assemblages in economically important eastern cottonwood (Populus deltoides Bartr.), sycamore (Platanus occidentalis L.) and sweetgum (Liquidambar styraciflua L.) plantations in the southeastern U.S.A. Furthermore, we compared insect responses between freshly-cut plant material by placing traps directly over cut hardwood logs (trap-logs), traps baited with ethanol lures and unbaited (control) traps. 2. We captured a total of 15 506 insects representing 127 species in four families in 2011 and 2013. Approximately 9% and 62% of total species and individuals, respectively, and 23% and 79% of total Scolytinae species and individuals, respectively, were non-native to North America. 3. We captured more Scolytinae using cottonwood trap-logs compared with control traps in both years, although this was the case with sycamore and sweetgum only in 2013. More woodborers were captured using cottonwood and sweetgum trap-logs compared with control traps in both years, although only with sycamore in 2013. 4. Ethanol was an effective lure for capturing non-native Scolytinae; however, not all non-native species were captured using ethanol lures. Ambrosiophilus atratus (Eichhoff) and Hypothenemus crudiae (Panzer) were captured with both trap-logs and control traps, whereas Coccotrypes distinctus (Motschulsky) and Xyleborus glabratus Eichhoff were only captured on trap-logs. 5. Indicator species analysis revealed that certain scolytines [e.g. Cnestus mutilates (Blandford) and Xylosandrus crassiusculus (Motschulsky)] showed significant associations with trap-logs or ethanol baits in poplar or sweetgum trap-logs. In general, the species composition of subcortical insects, especially woodboring insects, was distinct among the three tree species and between those associated with trap-logs and control traps.

  2. NETL CT Imaging Facility

    ScienceCinema (OSTI)

    None

    2014-05-21

    NETL's CT Scanner laboratory is equipped with three CT scanners and a mobile core logging unit that work together to provide characteristic geologic and geophysical information at different scales, non-destructively.

  3. NETL CT Imaging Facility

    SciTech Connect (OSTI)

    2013-09-04

    NETL's CT Scanner laboratory is equipped with three CT scanners and a mobile core logging unit that work together to provide characteristic geologic and geophysical information at different scales, non-destructively.

  4. Impact evaluation of energy conservation measures installed at Mayr Brothers Logging Company under the Energy Savings Plan

    SciTech Connect (OSTI)

    Brown, D.R.; Spanner, G.E.

    1995-05-01

    This impact evaluation of adjustable speed drives (ASDs), programmble logic controllers (PLCs), and high efficiency motors (HEMs) that were recently installed at Mayr Brothers Logging Co., Inc. (Mayr Bros.) was conducted for the Bonneville Power Administration (Bonneville) as part of an evaluation of its Energy $avings Plan (E$P) Program. The project consists of ASDs, PLCs, and HEMs that were installed at the Mayr Bros. new small log nill at their facility in Hoquiam, Washington. Energy savings directly accrue through improved motor efficiency and indirectly accrue via an increase in production rate. This latter effect reduces energy consumption per unit of production by spreading fixed energy requirements over a greater number of units. The objective of this impact evaluation was to assess how much electricity is being saved at Mayr Bros. as a result of the E$P and to determine how much the savings cost Bonneville and the region. The impact of the project was evaluated with a combination of engineering analysis, financial analysis, interviews, and submittal reviews (Mayr Bros. proposal and completion report). The energy conservation measures were incorporated into the small log mill while the mill was constructed in 1992 and 1993. Financing the new mill had stretched Mayr Bros. cash and credit resources to the limit. Without the acquisition payment, Mayr Bros. would not have been able to afford the additional investment in the energy conservation measures. Therefore, all of the project`s impact can be attributed to the E$P. The key recommendation resulting from this impact evaluation is to avoid the direct comparison of energy consumption estimates derived via engineering calculations and metering. If ``before and after`` metering is not possible, engineering calculations should be calibrated against metered data to enhance comparability.

  5. Is the assumption of normality or log-normality for continuous response data critical for benchmark dose estimation?

    SciTech Connect (OSTI)

    Shao, Kan; Gift, Jeffrey S.; Setzer, R. Woodrow

    2013-11-01

    Continuous responses (e.g. body weight) are widely used in risk assessment for determining the benchmark dose (BMD) which is used to derive a U.S. EPA reference dose. One critical question that is not often addressed in doseresponse assessments is whether to model the continuous data as normally or log-normally distributed. Additionally, if lognormality is assumed, and only summarized response data (i.e., mean standard deviation) are available as is usual in the peer-reviewed literature, the BMD can only be approximated. In this study, using the hybrid method and relative deviation approach, we first evaluate six representative continuous doseresponse datasets reporting individual animal responses to investigate the impact on BMD/BMDL estimates of (1) the distribution assumption and (2) the use of summarized versus individual animal data when a log-normal distribution is assumed. We also conduct simulation studies evaluating model fits to various known distributions to investigate whether the distribution assumption has influence on BMD/BMDL estimates. Our results indicate that BMDs estimated using the hybrid method are more sensitive to the distribution assumption than counterpart BMDs estimated using the relative deviation approach. The choice of distribution assumption has limited impact on the BMD/BMDL estimates when the within dose-group variance is small, while the lognormality assumption is a better choice for relative deviation method when data are more skewed because of its appropriateness in describing the relationship between mean and standard deviation. Additionally, the results suggest that the use of summarized data versus individual response data to characterize log-normal distributions has minimal impact on BMD estimates. - Highlights: We investigate to what extent the distribution assumption can affect BMD estimates. Both real data analysis and simulation study are conducted. BMDs estimated using hybrid method are more sensitive to distribution assumption. Summarized continuous data are adequate for BMD estimation.

  6. Summary Report of Geophysical Logging For The Seismic Boreholes Project at the Hanford Site Waste Treatment Plant.

    SciTech Connect (OSTI)

    Gardner, Martin G.; Price, Randall K.

    2007-02-01

    During the period of June through October 2006, three deep boreholes and one corehole were drilled beneath the site of the Waste Treatment Plant (WTP) at the U.S. Department of Energy (DOE) Hanford Site near Richland, Washington. The boreholes were drilled to provide information on ground-motion attenuation in the basalt and interbedded sediments underlying the WTP site. This report describes the geophysical logging of the deep boreholes that was conducted in support of the Seismic Boreholes Project, defined below. The detailed drilling and geological descriptions of the boreholes and seismic data collected and analysis of that data are reported elsewhere.

  7. Image Gallery

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    /about/history-innovation/trinity-to-trinity/_assets/images/trinity-banner10.jpg Image Gallery The Trinity Test of 1945 was the first full-scale, real-world test of a nuclear weapon; with the new Trinity supercomputer our goal is to do this virtually, in 3D. Click thumbnails to enlarge. Photos arranged by most recent first, horizontal formats before vertical. See Flickr for more sizes and details. Groves and Oppenheimer, 9-11-45 (799398) Groves and Oppenheimer, 9-11-45 (799398) Trinity (C761,

  8. Identification and Characterization of Hydrogeologic Units at the Nevada Test Site Using Geophysical Logs: Examples from the Underground Test Area Project

    SciTech Connect (OSTI)

    Lance Prothro, Sigmund Drellack, Margaret Townsend

    2009-03-25

    The diverse and complex geology of the Nevada Test Site region makes for a challenging environment for identifying and characterizing hydrogeologic units penetrated by wells drilled for the U.S. Department of Energy, National Nuclear Security Administration, Underground Test Area (UGTA) Environmental Restoration Sub-Project. Fortunately, UGTA geoscientists have access to large and robust sets of subsurface geologic data, as well as a large historical knowledge base of subsurface geological analyses acquired mainly during the underground nuclear weapons testing program. Of particular importance to the accurate identification and characterization of hydrogeologic units in UGTA boreholes are the data and interpretation principles associated with geophysical well logs. Although most UGTA participants and stakeholders are probably familiar with drill hole data such as drill core and cuttings, they may be less familiar with the use of geophysical logs; this document is meant to serve as a primer on the use of geophysical logs in the UGTA project. Standard geophysical logging tools used in the UGTA project to identify and characterize hydrogeologic units are described, and basic interpretation principles and techniques are explained. Numerous examples of geophysical log data from a variety of hydrogeologic units encountered in UGTA wells are presented to highlight the use and value of geophysical logs in the accurate hydrogeologic characterization of UGTA wells.

  9. Consortium for coal log pipeline research and development. Final technical progress report, August 10, 1993--August 9, 1996

    SciTech Connect (OSTI)

    Marrero, T.R.

    1996-10-01

    The main objective of this project was to conduct intensive research and development of the Coal Log Pipeline (CLP). Specifically, the R & D was to concentrate on previously neglected and insufficiently studied aspects of CLP which were deemed significant. With improvements in these areas, CLP could be implemented for commercial use within five years. CLP technology is capable of transporting coal logs for long distances. The many potential advantages of CLP over truck and railroad transportation include: lower freight costs, less energy consumption, less air pollution, decreased environmental problems, increased safety, and improved reliability. Previous studies have shown that CLP is advantageous over slurry pipeline technology. First, CLP uses one-third the water required by a coal slurry pipeline. Second, CLP provides easier coal dewatering. Third, the CLP conveying capacity of coal is twice as much as a slurry transport line of equal diameter. In many situations, the cost for transporting each ton of coal is expected to be less expensive by CLP as compared to other competing modes of transportation such as: truck, unit train and slurry pipeline.

  10. Imaging bolometer

    DOE Patents [OSTI]

    Wurden, Glen A. (Los Alamos, NM)

    1999-01-01

    Radiation-hard, steady-state imaging bolometer. A bolometer employing infrared (IR) imaging of a segmented-matrix absorber of plasma radiation in a cooled-pinhole camera geometry is described. The bolometer design parameters are determined by modeling the temperature of the foils from which the absorbing matrix is fabricated by using a two-dimensional time-dependent solution of the heat conduction equation. The resulting design will give a steady-state bolometry capability, with approximately 100 Hz time resolution, while simultaneously providing hundreds of channels of spatial information. No wiring harnesses will be required, as the temperature-rise data will be measured via an IR camera. The resulting spatial data may be used to tomographically investigate the profile of plasmas.

  11. Imaging bolometer

    DOE Patents [OSTI]

    Wurden, G.A.

    1999-01-19

    Radiation-hard, steady-state imaging bolometer is disclosed. A bolometer employing infrared (IR) imaging of a segmented-matrix absorber of plasma radiation in a cooled-pinhole camera geometry is described. The bolometer design parameters are determined by modeling the temperature of the foils from which the absorbing matrix is fabricated by using a two-dimensional time-dependent solution of the heat conduction equation. The resulting design will give a steady-state bolometry capability, with approximately 100 Hz time resolution, while simultaneously providing hundreds of channels of spatial information. No wiring harnesses will be required, as the temperature-rise data will be measured via an IR camera. The resulting spatial data may be used to tomographically investigate the profile of plasmas. 2 figs.

  12. Manhattan Project: Places Images

    Office of Scientific and Technical Information (OSTI)

    PLACES IMAGES Resources > Photo Gallery Scroll down to see each of these images individually. The images are: 1. Remains of a Shinto Shrine, Nagasaki, October 1945 (courtesy the ...

  13. Nuclear Imaging | Jefferson Lab

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Research Jefferson Lab's Radiation Detector and Imaging Group Members of Jefferson Lab's Radiation Detector & Medical Imaging Group design and build unique imaging devices based on...

  14. Magnetic particle imaging of blood coagulation

    SciTech Connect (OSTI)

    Murase, Kenya Song, Ruixiao; Hiratsuka, Samu

    2014-06-23

    We investigated the feasibility of visualizing blood coagulation using a system for magnetic particle imaging (MPI). A magnetic field-free line is generated using two opposing neodymium magnets and transverse images are reconstructed from the third-harmonic signals received by a gradiometer coil, using the maximum likelihood-expectation maximization algorithm. Our MPI system was used to image the blood coagulation induced by adding CaCl{sub 2} to whole sheep blood mixed with magnetic nanoparticles (MNPs). The “MPI value” was defined as the pixel value of the transverse image reconstructed from the third-harmonic signals. MPI values were significantly smaller for coagulated blood samples than those without coagulation. We confirmed the rationale of these results by calculating the third-harmonic signals for the measured viscosities of samples, with an assumption that the magnetization and particle size distribution of MNPs obey the Langevin equation and log-normal distribution, respectively. We concluded that MPI can be useful for visualizing blood coagulation.

  15. Methods and apparatus to produce stick-slip motion of logging tool attached to a wireline drawn upward by a continuously rotating wireline drum

    DOE Patents [OSTI]

    Vail, W.B. III; Momii, S.T.

    1998-02-10

    Methods and apparatus are described to produce stick-slip motion of a logging tool within a cased well attached to a wireline that is drawn upward by a continuously rotating wireline drum. The stick-slip motion results in the periodic upward movement of the tool in the cased well described in terms of a dwell time during which time the tool is stationary, the move time during which time the tool moves, and the stroke that is upward distance that the tool translates during the ``slip`` portion of the stick-slip motion. This method of measurement is used to log the well at different vertical positions of the tool. Therefore, any typical ``station-to-station logging tool`` may be modified to be a ``continuous logging tool,`` where ``continuous`` means that the wireline drum continually rotates while the tool undergoes stick-slip motion downhole and measurements are performed during the dwell times when the tool is momentarily stationary. The stick-slip methods of operation and the related apparatus are particularly described in terms of making measurements of formation resistivity from within a cased well during the dwell times when the tool is momentarily stationary during the periodic stick-slip motion of the logging tool. 12 figs.

  16. Methods and apparatus to produce stick-slip motion of logging tool attached to a wireline drawn upward by a continuously rotating wireline drum

    DOE Patents [OSTI]

    Vail, III, William Banning; Momii, Steven Thomas

    1998-01-01

    Methods and apparatus are described to produce stick-slip motion of a logging tool within a cased well attached to a wireline that is drawn upward by a continuously rotating wireline drum. The stick-slip motion results in the periodic upward movement of the tool in the cased well described in terms of a dwell time during which time the tool is stationary, the move time during which time the tool moves, and the stroke that is upward distance that the tool translates during the "slip" portion of the stick-slip motion. This method of measurement is used to log the well at different vertical positions of the tool. Therefore, any typical "station-to-station logging tool" may be modified to be a "continuous logging tool", where "continuous" means that the wireline drum continually rotates while the tool undergoes stick-slip motion downhole and measurements are performed during the dwell times when the tool is momentarily stationary. The stick-slip methods of operation and the related apparatus are particularly described in terms of making measurements of formation resistivity from within a cased well during the dwell times when the tool is momentarily stationary during the periodic stick-slip motion of the logging tool.

  17. Lensless imaging

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    4 Lensless Imaging of Magnetic Nanostructures by X-ray Spectro-Holography J. Lüning, W. F. Schlotter and J. Stöhr (SSRL) The unprecedented properties of X-ray free electron lasers (X-FELs) under development world wide will open the door for entirely new classes of experiments. The ultra-short time structure of the ultra-bright x-ray pulses will revolutionize the field of femtosecond x-ray science, since it will become possible to obtain sufficient information about a system from probing it

  18. ImageJ

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ImageJ ImageJ Description and Overview ImageJ is a public domain Java image processing program inspired by NIH Image. Fiji means Fiji is Just ImageJ, and stands for a customization of ImageJ with tools to handle microscope data. ImageJ/Fiji can display, edit, analyze, process, save and print 8-bit, 16-bit and 32-bit images. It can read many image formats including TIFF, GIF, JPEG, BMP, DICOM, FITS and "raw". It supports "stacks", a series of images that share a single window.

  19. Sandia National Laboratories: Z Pulsed Power Facility: Image Gallery

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Image Gallery .

  20. Fracture detection logging tool

    DOE Patents [OSTI]

    Benzing, William M.

    1992-06-09

    A method and apparatus by which fractured rock formations are identified and their orientation may be determined includes two orthogonal motion sensors which are used in conjunction with a downhole orbital vibrator. The downhole vibrator includes a device for orienting the sensors. The output of the sensors is displayed as a lissajou figure. The shape of the figure changes when a subsurface fracture is encountered in the borehole. The apparatus and method identifies fractures rock formations and enables the azimuthal orientation of the fractures to be determined.

  1. FOIA Log 2012.xlsx

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    FOIA Announcement FOIA Announcement November 4, 2014 - 12:04pm Addthis R--FOIA Support Services for the U.S. Department of Energy Solicitation Number: DE-SOL-0007713 Notice Type: Sources Sought Synopsis Added: Oct 28, 2014 Response Date: Nov 13, 2014 This announcement serves as a Sources Sought synopsis issued for the purpose of market research in accordance with Federal Acquisition Regulation (FAR) Part 10. This Sources Sought is issued solely for information and planning purposes and does not

  2. FOIA Log 2013.xlsx

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Rec'd Requestor HQ, EMCBC or Direct Subject 2/12/13 e-mail to HQ 13-001 10/4/2012 2/4/2013 Jehan Patterson HQ Rec'd 02/01/2013 Ten Categories of Records Since January 1, 2011 Related to DOE Computer Networks (HQ-2012-00062-F/Jehan Patterson) 3/5/13 13-025 13-002 3/5/2013 3/4/2013 Kacee Jackson Direct Request for Buyer Information for Any Buyers, Contracting Officers, or Credit Card Holders 8/6/13 e-mail to CBFO 13-003 7/31/2013 7/31/2013 Mary Grant Direct Miller Act Bond Copy Request for the

  3. Logging in to Hopper

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    it so that the applications run on the Hopper compute nodes. Accelerated X11 Performance NX is a freely available software package that greatly improves X11 performance over the...

  4. Logging in to Edison

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    so that the applications run on the Edison compute nodes. Accelerated X11 Performance NX is a freely available software package that greatly improves X11 performance over the...

  5. Induction logging device

    DOE Patents [OSTI]

    Koelle, A.R.; Landt, J.A.

    An instrument is disclosed for mapping vertical conductive fractures in a resistive bedrock, magnetically inducing eddy currents by a pair of vertically oriented, mutually perpendicular, coplanar coils. The eddy currents drive magnetic fields which are picked up by a second, similar pair of coils.

  6. Job Logs & Statistics

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Queue Status Queue Wait Times Completed Batch Jobs Completed Parallel Jobs Usage Reports Benchmark Monitoring Application Performance Training & Tutorials Software Policies User Surveys NERSC Users Group User Announcements Help Staff Blogs Request Repository Mailing List Operations for: Passwords & Off-Hours Status 1-800-66-NERSC, option 1 or 510-486-6821 Account Support https://nim.nersc.gov accounts@nersc.gov 1-800-66-NERSC, option 2 or 510-486-8612 Consulting http://help.nersc.gov

  7. Logging in to Franklin

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Freedom is suitable for running memory-intensive utilities and serial programs like IDL, DDT, parallel make, hsi, and htar. The command to access Freedom is: % ssh -l username...

  8. FOIA Log 2014.xlsx

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    from 09012013 To Present 42214 14-0239 14-005 3252014 3252014 Kenneth Fletcher, Exchange Monitor Publications HQ - 2014- 00727-F Communicatiuons between WIPP M&O...

  9. Recovery Efficiency Test Project: Phase 1, Activity report. Volume 1: Site selection, drill plan preparation, drilling, logging, and coring operations

    SciTech Connect (OSTI)

    Overbey, W.K. Jr.; Carden, R.S.; Kirr, J.N.

    1987-04-01

    The recovery Efficiency Test well project addressed a number of technical issues. The primary objective was to determine the increased efficiency gas recovery of a long horizontal wellbore over that of a vertical wellbore and, more specifically, what improvements can be expected from inducing multiple hydraulic fractures from such a wellbore. BDM corporation located, planned, and drilled a long radius turn horizontal well in the Devonian shale Lower Huron section in Wayne County, West Virginia, demonstrating that state-of-the-art technology is capable of drilling such wells. BDM successfully tested drilling, coring, and logging in a horizontal well using air as the circulating medium; conducted reservoir modeling studies to protect flow rates and reserves in advance of drilling operations; observed two phase flow conditions in the wellbore not observed previously; cored a fracture zone which produced gas; observed that fractures in the core and the wellbore were not systematically spaced (varied from 5 to 68 feet in different parts of the wellbore); observed that highest gas show rates reported by the mud logger corresponded to zone with lowest fracture spacing (five feet) or high fracture frequency. Four and one-half inch casting was successfully installed in the borehole and was equipped to isolate the horizontal section into eight (8) zones for future testing and stimulation operations. 6 refs., 48 figs., 10 tabs.

  10. Split image optical display

    DOE Patents [OSTI]

    Veligdan, James T. (Manorville, NY)

    2007-05-29

    A video image is displayed from an optical panel by splitting the image into a plurality of image components, and then projecting the image components through corresponding portions of the panel to collectively form the image. Depth of the display is correspondingly reduced.

  11. Split image optical display

    DOE Patents [OSTI]

    Veligdan, James T.

    2005-05-31

    A video image is displayed from an optical panel by splitting the image into a plurality of image components, and then projecting the image components through corresponding portions of the panel to collectively form the image. Depth of the display is correspondingly reduced.

  12. Manhattan Project: Image Retouching`

    Office of Scientific and Technical Information (OSTI)

    Image Retouching Resources > Photo Gallery Smyth Report (original) Smyth Report (retouched) Images on this web site have sometimes been "retouched." In every case, however, the ...

  13. AVTA Federal Fleet PEV Readiness Data Logging and Characterization Study for the National Park Service: Fort Vancouver National Historic Site

    SciTech Connect (OSTI)

    Stephen Schey; Jim Francfort

    2014-03-01

    Battelle Energy Alliance, LLC, managing and operating contractor for the U.S. Department of Energy’s Idaho National Laboratory, is the lead laboratory for the U.S. Department of Energy’s Advanced Vehicle Testing. Battelle Energy Alliance, LLC contracted with Intertek Testing Services, North America (ITSNA) to collect data on federal fleet operations as part of the Advanced Vehicle Testing Activity’s Federal Fleet Vehicle Data Logging and Characterization study. The Advanced Vehicle Testing Activity study seeks to collect data to validate the use of advanced electric drive vehicle transportation. This report focuses on the Fort Vancouver National Historic Site (FVNHS) fleet to identify daily operational characteristics of select vehicles and report findings on vehicle and mission characterizations to support the successful introduction of electric vehicles (EVs) into the agencies’ fleet. Individual observations of the selected vehicles provided the basis for recommendations related to EV adoption and whether a battery electric vehicle (BEV) or plug-in hybrid electric vehicle (PHEV) (collectively plug-in electric vehicles) could fulfill the mission requirements. FVNHS identified three vehicles in its fleet for consideration. While the FVNHS vehicles conduct many different missions, only two (i.e., support and pool missions) were selected by agency management to be part of this fleet evaluation. The logged vehicles included a pickup truck and a minivan. This report will show that BEVs and PHEVs are capable of performing the required missions and providing an alternative vehicle for both mission categories, because each has sufficient range for individual trips and time available each day for charging to accommodate multiple trips per day. These charging events could occur at the vehicle’s home base, high-use work areas, or in intermediate areas along routes that the vehicles frequently travel. Replacement of vehicles in the current fleet would result in significant reductions in emission of greenhouse gases and petroleum use, while also reducing fuel costs. The Vancouver, Washington area and neighboring Portland, Oregon are leaders in adoption of PEVs in the United States1. PEV charging stations, or more appropriately identified as electric vehicle supply equipment, located on the FVNHS facility would be a benefit for both FVNHS fleets and general public use. Fleet drivers and park visitors operating privately owned plug-in electric vehicles benefit by using the charging infrastructure. ITSNA recommends location analysis of the FVNHS site to identify the optimal station placement for electric vehicle supply equipment. ITSNA recognizes the support of Idaho National Laboratory and ICF International for their efforts to initiate communication with the National Parks Service and FVNHS for participation in this study. ITSNA is pleased to provide this report and is encouraged by the high interest and support from the National Park Service and FVNHS personnel

  14. Determination of Transport Properties From Flowing Fluid Temperature LoggingIn Unsaturated Fractured Rocks: Theory And Semi-Analytical Solution

    SciTech Connect (OSTI)

    Mukhopadhyay, Sumit; Tsang, Yvonne W.

    2008-08-01

    Flowing fluid temperature logging (FFTL) has been recently proposed as a method to locate flowing fractures. We argue that FFTL, backed up by data from high-precision distributed temperature sensors, can be a useful tool in locating flowing fractures and in estimating the transport properties of unsaturated fractured rocks. We have developed the theoretical background needed to analyze data from FFTL. In this paper, we present a simplified conceptualization of FFTL in unsaturated fractured rock, and develop a semianalytical solution for spatial and temporal variations of pressure and temperature inside a borehole in response to an applied perturbation (pumping of air from the borehole). We compare the semi-analytical solution with predictions from the TOUGH2 numerical simulator. Based on the semi-analytical solution, we propose a method to estimate the permeability of the fracture continuum surrounding the borehole. Using this proposed method, we estimated the effective fracture continuum permeability of the unsaturated rock hosting the Drift Scale Test (DST) at Yucca Mountain, Nevada. Our estimate compares well with previous independent estimates for fracture permeability of the DST host rock. The conceptual model of FFTL presented in this paper is based on the assumptions of single-phase flow, convection-only heat transfer, and negligible change in system state of the rock formation. In a sequel paper [Mukhopadhyay et al., 2008], we extend the conceptual model to evaluate some of these assumptions. We also perform inverse modeling of FFTL data to estimate, in addition to permeability, other transport parameters (such as porosity and thermal conductivity) of unsaturated fractured rocks.

  15. Logs of wells and boreholes drilled during hydrogeologic studies at Lawrence Livermore National Laboratory Site 300, January 1, 1982--June 30, 1988: January 1, 1982 through June 30, 1988

    SciTech Connect (OSTI)

    Toney, K.C.; Crow, N.B.

    1988-01-01

    We present the hydrogeologic well logs for monitor wells and exploratory boreholes drilled at Lawrence Livermore National Laboratory (LLNL) Site 300 between the beginning of environmental investigations in June 1982 and the end of June 1988. These wells and boreholes were drilled as part of studies made to determine the horizontal and vertical distribution of volatile organic compounds (VOCs), high explosive (HE) compounds, and tritium in soil, rock, and ground water at Site 300. The well logs for 293 installations comprise the bulk of this report. We have prepared summaries of Site 300 geology and project history that provide a context for the well logs. Many of the logs in this report have also been published in previous topical reports, but they are nevertheless included in order to make this report a complete record of the wells and boreholes drilled prior to July 1988. A commercially available computer program, LOGGER has been used since late 1985 to generate these logs. This report presents details of the software programs and the hardware used. We are presently completing a project to devise a computer-aided design (CAD) system to produce hydrogeologic cross sections and fence diagrams, utilizing the digitized form of these logs. We find that our system produces publication-quality well and exploratory borehole logs at a lower cost than that of logs drafted by traditional methods.

  16. Seismic Imaging and Monitoring

    SciTech Connect (OSTI)

    Huang, Lianjie

    2012-07-09

    I give an overview of LANL's capability in seismic imaging and monitoring. I present some seismic imaging and monitoring results, including imaging of complex structures, subsalt imaging of Gulf of Mexico, fault/fracture zone imaging for geothermal exploration at the Jemez pueblo, time-lapse imaging of a walkway vertical seismic profiling data for monitoring CO{sub 2} inject at SACROC, and microseismic event locations for monitoring CO{sub 2} injection at Aneth. These examples demonstrate LANL's high-resolution and high-fidelity seismic imaging and monitoring capabilities.

  17. Image registration method for medical image sequences

    DOE Patents [OSTI]

    Gee, Timothy F.; Goddard, James S.

    2013-03-26

    Image registration of low contrast image sequences is provided. In one aspect, a desired region of an image is automatically segmented and only the desired region is registered. Active contours and adaptive thresholding of intensity or edge information may be used to segment the desired regions. A transform function is defined to register the segmented region, and sub-pixel information may be determined using one or more interpolation methods.

  18. AVTA Federal Fleet PEV Readiness Data Logging and Characterization Study for the National Park Service: Golden Gate National Recreation Area

    SciTech Connect (OSTI)

    Stephen Schey; Jim Francfort

    2014-03-01

    Battelle Energy Alliance, LLC, managing and operating contractor for the U.S. Department of Energy's Idaho National Laboratory, is the lead laboratory for U.S. Department of Energy Advanced Vehicle Testing. Battelle Energy Alliance, LLC contracted with Intertek Testing Services, North America (ITSNA) to collect data on federal fleet operations as part of the Advanced Vehicle Testing Activity's Federal Fleet Vehicle Data Logging and Characterization study. The Advanced Vehicle Testing Activity study seeks to collect data to validate the utilization of advanced electric drive vehicle transportation. This report focuses on the Golden Gate National Recreation Area (GGNRA) fleet to identify daily operational characteristics of select vehicles and report findings on vehicle and mission characterizations to support the successful introduction of plug-in electric vehicles (PEVs) into the agencies' fleets. Individual observations of these selected vehicles provide the basis for recommendations related to electric vehicle adoption and whether a battery electric vehicle or plug-in hybrid electric vehicle (PHEV) (collectively PEVs) can fulfill the mission requirements. GGNRA identified 182 vehicles in its fleet, which are under the management of the U.S. General Services Administration. Fleet vehicle mission categories are defined in Section 4, and while the GGNRA vehicles conduct many different missions, only two (i.e., support and law enforcement missions) were selected by agency management to be part of this fleet evaluation. The selected vehicles included sedans, trucks, and sport-utility vehicles. This report will show that battery electric vehicles and/or PHEVs are capable of performing the required missions and providing an alternative vehicle for support vehicles and PHEVs provide the same for law enforcement, because each has a sufficient range for individual trips and time is available each day for charging to accommodate multiple trips per day. These charging events could occur at the vehicle home base, high-use work areas, or intermediately along routes that the vehicles frequently travel. Replacement of vehicles in the current fleet would result in significant reductions in the emission of greenhouse gases and petroleum use, while also reducing fuel costs. The San Francisco Bay Area is a leader in the adoption of PEVs in the United States. PEV charging stations, or more appropriately identified as electric vehicle supply equipment, located on the GGNRA facility would be a benefit for both GGNRA fleets and general public use. Fleet drivers and park visitors operating privately owned PEVs benefit by using the charging infrastructure. ITSNA recommends location analysis of the GGNRA site to identify the optimal placement of the electric vehicle supply equipment station. ITSNA recognizes the support of Idaho National Laboratory and ICF International for their efforts to initiate communication with the National Parks Service and GGNRA for participation in the study. ITSNA is pleased to provide this report and is encouraged by the high interest and support from the National Park Service and GGNRA personnel.

  19. ARM - Measurement - Aerosol image

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    would love to hear from you Send us a note below or call us at 1-888-ARM-DATA. Send Measurement : Aerosol image Images of aerosols from which one can derive characteristics such...

  20. Spectrographic imaging system

    DOE Patents [OSTI]

    Morris, Michael D.; Treado, Patrick J.

    1991-01-01

    An imaging system for providing spectrographically resolved images. The system incorporates a one-dimensional spatial encoding mask which enables an image to be projected onto a two-dimensional image detector after spectral dispersion of the image. The dimension of the image which is lost due to spectral dispersion on the two-dimensional detector is recovered through employing a reverse transform based on presenting a multiplicity of different spatial encoding patterns to the image. The system is especially adapted for detecting Raman scattering of monochromatic light transmitted through or reflected from physical samples. Preferably, spatial encoding is achieved through the use of Hadamard mask which selectively transmits or blocks portions of the image from the sample being evaluated.

  1. Video image position determination

    DOE Patents [OSTI]

    Christensen, Wynn; Anderson, Forrest L.; Kortegaard, Birchard L.

    1991-01-01

    An optical beam position controller in which a video camera captures an image of the beam in its video frames, and conveys those images to a processing board which calculates the centroid coordinates for the image. The image coordinates are used by motor controllers and stepper motors to position the beam in a predetermined alignment. In one embodiment, system noise, used in conjunction with Bernoulli trials, yields higher resolution centroid coordinates.

  2. Near-electrode imager

    DOE Patents [OSTI]

    Rathke, Jerome W.; Klingler, Robert J.; Woelk, Klaus; Gerald, II, Rex E.

    2000-01-01

    An apparatus, near-electrode imager, for employing nuclear magnetic resonance imaging to provide in situ measurements of electrochemical properties of a sample as a function of distance from a working electrode. The near-electrode imager uses the radio frequency field gradient within a cylindrical toroid cavity resonator to provide high-resolution nuclear magnetic resonance spectral information on electrolyte materials.

  3. Medical imaging systems

    DOE Patents [OSTI]

    Frangioni, John V

    2013-06-25

    A medical imaging system provides simultaneous rendering of visible light and diagnostic or functional images. The system may be portable, and may include adapters for connecting various light sources and cameras in open surgical environments or laparascopic or endoscopic environments. A user interface provides control over the functionality of the integrated imaging system. In one embodiment, the system provides a tool for surgical pathology.

  4. Deep Sky Astronomical Image Database

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Deep Sky Astronomical Image Database Deep Sky Astronomical Image Database Key Challenges: Develop, store, analyze, and make available an astronomical image database of...

  5. Fourier plane imaging microscopy

    SciTech Connect (OSTI)

    Dominguez, Daniel Peralta, Luis Grave de; Alharbi, Nouf; Alhusain, Mdhaoui; Bernussi, Ayrton A.

    2014-09-14

    We show how the image of an unresolved photonic crystal can be reconstructed using a single Fourier plane (FP) image obtained with a second camera that was added to a traditional compound microscope. We discuss how Fourier plane imaging microscopy is an application of a remarkable property of the obtained FP images: they contain more information about the photonic crystals than the images recorded by the camera commonly placed at the real plane of the microscope. We argue that the experimental results support the hypothesis that surface waves, contributing to enhanced resolution abilities, were optically excited in the studied photonic crystals.

  6. IN-SITU ASSAY OF TRANSURANIC RADIONUCLIDES IN THE VADOSE ZONE USING HIGH-RESOLUTION SPECTRAL GAMMA LOGGING - A HANFORD CASE STUDY

    SciTech Connect (OSTI)

    ROHAY VJ; HENWOOD P; MCCAIN R

    2009-11-30

    High-resolution spectral gamma logging in steel-cased boreholes is used to detect and quantify transuranic radionuclides in the subsurface. Pu-239, Pu-241, Am-241, and Np-237 are identified based on characteristic decay gammas. Typical minimum detectable levels are on the order of 20 to 40 nCi/g. In intervals of high transuranic concentrations, gamma rays from other sources may complicate analysis and interpretation. Gamma rays detected in the borehole may originate from three sources: decay of the parent transuranic radionuclide or a daughter; alpha interactions; and interactions with neutrons resulting from either spontaneous fission or alpha particle interactions.

  7. Remedial Action Plan and Site Design for Stabilization of the Inactive Uranium Mill Tailings Sites at Slick Rock, Colorado: Appendix B to Attachment 3, Lithologic logs and monitor well construction information. Final report

    SciTech Connect (OSTI)

    1995-09-01

    This volume contains lithology logs and monitor well construction information for: NC processing site; UC processing site; and Burro Canyon disposal site. This information pertains to the ground water hydrology investigations which is attachment 3 of this series of reports.

  8. Image compression technique

    DOE Patents [OSTI]

    Fu, C.Y.; Petrich, L.I.

    1997-03-25

    An image is compressed by identifying edge pixels of the image; creating a filled edge array of pixels each of the pixels in the filled edge array which corresponds to an edge pixel having a value equal to the value of a pixel of the image array selected in response to the edge pixel, and each of the pixels in the filled edge array which does not correspond to an edge pixel having a value which is a weighted average of the values of surrounding pixels in the filled edge array which do correspond to edge pixels; and subtracting the filled edge array from the image array to create a difference array. The edge file and the difference array are then separately compressed and transmitted or stored. The original image is later reconstructed by creating a preliminary array in response to the received edge file, and adding the preliminary array to the received difference array. Filling is accomplished by solving Laplace`s equation using a multi-grid technique. Contour and difference file coding techniques also are described. The techniques can be used in a method for processing a plurality of images by selecting a respective compression approach for each image, compressing each of the images according to the compression approach selected, and transmitting each of the images as compressed, in correspondence with an indication of the approach selected for the image. 16 figs.

  9. Image compression technique

    DOE Patents [OSTI]

    Fu, Chi-Yung; Petrich, Loren I.

    1997-01-01

    An image is compressed by identifying edge pixels of the image; creating a filled edge array of pixels each of the pixels in the filled edge array which corresponds to an edge pixel having a value equal to the value of a pixel of the image array selected in response to the edge pixel, and each of the pixels in the filled edge array which does not correspond to an edge pixel having a value which is a weighted average of the values of surrounding pixels in the filled edge array which do correspond to edge pixels; and subtracting the filled edge array from the image array to create a difference array. The edge file and the difference array are then separately compressed and transmitted or stored. The original image is later reconstructed by creating a preliminary array in response to the received edge file, and adding the preliminary array to the received difference array. Filling is accomplished by solving Laplace's equation using a multi-grid technique. Contour and difference file coding techniques also are described. The techniques can be used in a method for processing a plurality of images by selecting a respective compression approach for each image, compressing each of the images according to the compression approach selected, and transmitting each of the images as compressed, in correspondence with an indication of the approach selected for the image.

  10. IMPROVED V I log(gf) VALUES AND ABUNDANCE DETERMINATIONS IN THE PHOTOSPHERES OF THE SUN AND METAL-POOR STAR HD 84937

    SciTech Connect (OSTI)

    Lawler, J. E.; Wood, M. P.; Den Hartog, E. A.; Feigenson, T.; Sneden, C.; Cowan, J. J. E-mail: mpwood@wisc.edu E-mail: tfeigenson@wisc.edu E-mail: cowan@nhn.ou.edu

    2015-01-01

    New emission branching fraction measurements for 836 lines of the first spectrum of vanadium (V I) are determined from hollow cathode lamp spectra recorded with the National Solar Observatory 1 m Fourier transform spectrometer (FTS) and a high-resolution echelle spectrometer. The branching fractions are combined with recently published radiative lifetimes from laser-induced fluorescence measurements to determine accurate absolute atomic transition probabilities for the 836 lines. The FTS data are also used to extract new hyperfine structure A coefficients for 26 levels of neutral vanadium. These new laboratory data are applied to determine the V abundance in the Sun and metal-poor star HD 84937, yielding log ε(V) = 3.956 ± 0.004 (σ = 0.037) based on 93 V I lines and log ε(V) = 1.89 ± 0.03 (σ = 0.07) based on nine V I lines, respectively, using the Holweger-Müller 1D model. These new V I abundance values for the Sun and HD 84937 agree well with our earlier determinations based upon V II.

  11. Polychromatic sparse image reconstruction and mass attenuation spectrum estimation via B-spline basis function expansion

    SciTech Connect (OSTI)

    Gu, Renliang E-mail: ald@iastate.edu; Dogandžić, Aleksandar E-mail: ald@iastate.edu

    2015-03-31

    We develop a sparse image reconstruction method for polychromatic computed tomography (CT) measurements under the blind scenario where the material of the inspected object and the incident energy spectrum are unknown. To obtain a parsimonious measurement model parameterization, we first rewrite the measurement equation using our mass-attenuation parameterization, which has the Laplace integral form. The unknown mass-attenuation spectrum is expanded into basis functions using a B-spline basis of order one. We develop a block coordinate-descent algorithm for constrained minimization of a penalized negative log-likelihood function, where constraints and penalty terms ensure nonnegativity of the spline coefficients and sparsity of the density map image in the wavelet domain. This algorithm alternates between a Nesterov’s proximal-gradient step for estimating the density map image and an active-set step for estimating the incident spectrum parameters. Numerical simulations demonstrate the performance of the proposed scheme.

  12. Imaging arrangement and microscope

    DOE Patents [OSTI]

    Pertsinidis, Alexandros; Chu, Steven

    2015-12-15

    An embodiment of the present invention is an imaging arrangement that includes imaging optics, a fiducial light source, and a control system. In operation, the imaging optics separate light into first and second tight by wavelength and project the first and second light onto first and second areas within first and second detector regions, respectively. The imaging optics separate fiducial light from the fiducial light source into first and second fiducial light and project the first and second fiducial light onto third and fourth areas within the first and second detector regions, respectively. The control system adjusts alignment of the imaging optics so that the first and second fiducial light projected onto the first and second detector regions maintain relatively constant positions within the first and second detector regions, respectively. Another embodiment of the present invention is a microscope that includes the imaging arrangement.

  13. Video Toroid Cavity Imager

    DOE Patents [OSTI]

    Gerald, II, Rex E.; Sanchez, Jairo; Rathke, Jerome W.

    2004-08-10

    A video toroid cavity imager for in situ measurement of electrochemical properties of an electrolytic material sample includes a cylindrical toroid cavity resonator containing the sample and employs NMR and video imaging for providing high-resolution spectral and visual information of molecular characteristics of the sample on a real-time basis. A large magnetic field is applied to the sample under controlled temperature and pressure conditions to simultaneously provide NMR spectroscopy and video imaging capabilities for investigating electrochemical transformations of materials or the evolution of long-range molecular aggregation during cooling of hydrocarbon melts. The video toroid cavity imager includes a miniature commercial video camera with an adjustable lens, a modified compression coin cell imager with a fiat circular principal detector element, and a sample mounted on a transparent circular glass disk, and provides NMR information as well as a video image of a sample, such as a polymer film, with micrometer resolution.

  14. Radiation imaging system

    DOE Patents [OSTI]

    Immel, David M.; Bobbit, III, John T.; Plummer, Jean R.; Folsom, Matthew D.; Serrato, Michael G.

    2016-03-22

    A radiation imaging system includes a casing and a camera disposed inside the casing. A first field of view through the casing exposes the camera to light from outside of the casing. An image plate is disposed inside the casing, and a second field of view through the casing to the image plate exposes the image plate to high-energy particles produced by a radioisotope outside of the casing. An optical reflector that is substantially transparent to the high-energy particles produced by the radioisotope is disposed with respect to the camera and the image plate to reflect light to the camera and to allow the high-energy particles produced by the radioisotope to pass through the optical reflector to the image plate.

  15. imageMCR

    Energy Science and Technology Software Center (OSTI)

    2011-09-27

    imageMCR is a user friendly software package that consists of a variety inputs to preprocess and analyze the hyperspectral image data using multivariate algorithms such as Multivariate Curve Resolution (MCR), Principle Component Analysis (PCA), Classical Least Squares (CLS) and Parallel Factor Analysis (PARAFAC). MCR provides a relative quantitative analysis of the hyperspectral image data without the need for standards, and it discovers all the emitting species (spectral pure components) present in an image, even thosemore » in which there is no a priori information. Once the spectral components are discovered, these spectral components can be used for future MCR analyses or used with CLS algorithms to quickly extract concentration image maps for each component within spectral image data sets.« less

  16. Imaging | Argonne National Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    SciTech Connect Technical Report: Imaging with Spherically Bent Crystals or Reflectors Citation Details In-Document Search Title: Imaging with Spherically Bent Crystals or Reflectors This paper consists of two parts: Part I describes the working principle of a recently developed x-ray imaging crystal spectrometer, where the astigmatism of spherically bent crystals is being used with advantage to record spatially resolved spectra of highly charged ions for Doppler measurements of the

  17. Manhattan Project: Events Images

    Office of Scientific and Technical Information (OSTI)

    Resources About this Site How to Navigate this Site Library Maps Note on Sources Nuclear Energy and the Public's Right to Know Photo Gallery Site Map Sources and Notes Suggested Readings EVENTS IMAGES Resources > Photo Gallery Page Content Here Scroll down to see each of these images individually. The images are: 1. Albert Einstein and Leo Szilard (courtesy the Federation of American Scientists); 2. Painting of CP-1 going critical (courtesy the National Archives); 3. An Alpha Racetrack inside

  18. Beam imaging sensor

    DOE Patents [OSTI]

    McAninch, Michael D; Root, Jeffrey J

    2015-03-31

    The present invention relates generally to the field of sensors for beam imaging and, in particular, to a new and useful beam imaging sensor for use in determining, for example, the power density distribution of a beam including, but not limited to, an electron beam or an ion beam. In one embodiment, the beam imaging sensor of the present invention comprises, among other items, a circumferential slit that is either circular, elliptical or polygonal in nature.

  19. Hyperspectral image reconstruction for x-ray fluorescence tomography

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Grsoy, Do?a; Bier, Tekin; Lanzirotti, Antonio; Newville, Matthew G.; De Carlo, Francesco

    2015-01-01

    A penalized maximum-likelihood estimation is proposed to perform hyperspectral (spatio-spectral) image reconstruction for X-ray fluorescence tomography. The approach minimizes a Poisson-based negative log-likelihood of the observed photon counts, and uses a penalty term that has the effect of encouraging local continuity of model parameter estimates in both spatial and spectral dimensions simultaneously. The performance of the reconstruction method is demonstrated with experimental data acquired from a seed of arabidopsis thaliana collected at the 13-ID-E microprobe beamline at the Advanced Photon Source. The resulting element distribution estimates with the proposed approach show significantly better reconstruction quality than the conventional analytical inversionmoreapproaches, and allows for a high data compression factor which can reduce data acquisition times remarkably. In particular, this technique provides the capability to tomographically reconstruct full energy dispersive spectra without compromising reconstruction artifacts that impact the interpretation of results.less

  20. Hyperspectral image reconstruction for x-ray fluorescence tomography

    SciTech Connect (OSTI)

    Grsoy, Do?a; Bier, Tekin; Lanzirotti, Antonio; Newville, Matthew G.; De Carlo, Francesco

    2015-01-01

    A penalized maximum-likelihood estimation is proposed to perform hyperspectral (spatio-spectral) image reconstruction for X-ray fluorescence tomography. The approach minimizes a Poisson-based negative log-likelihood of the observed photon counts, and uses a penalty term that has the effect of encouraging local continuity of model parameter estimates in both spatial and spectral dimensions simultaneously. The performance of the reconstruction method is demonstrated with experimental data acquired from a seed of arabidopsis thaliana collected at the 13-ID-E microprobe beamline at the Advanced Photon Source. The resulting element distribution estimates with the proposed approach show significantly better reconstruction quality than the conventional analytical inversion approaches, and allows for a high data compression factor which can reduce data acquisition times remarkably. In particular, this technique provides the capability to tomographically reconstruct full energy dispersive spectra without compromising reconstruction artifacts that impact the interpretation of results.

  1. Reconstruction of petrophysical images using cross-well traveltime tomography

    SciTech Connect (OSTI)

    Mendoza-Amuchastegui, J.A.; Ramirez-Cruz, L.C.

    1994-12-31

    In this paper the authors present the results obtained from a cross-well seismic tomography experiment carried out in an oil producing field of the West Permian Basin, Texas. Three fundamental stages can be identified from the tomographic method: field data acquisition, data conditioning, and the actual tomographic process including forward modeling and inversion. For this case, they present a synopsis of each. The resulting V{sub P} and V{sub S} tomograms show a clear separation of high and low velocity zones that are in agreement with sonic logs. From the final tomograms, they computed images of V{sub P}/V{sub S} ratio, Poisson ratio, porosity and density using well known empirical formulas. The results attained from the experiment provide an idea of the potential usefulness of the tomographic method as an alternative for in-field exploration and detailed characterization of hydrocarbon producing reservoirs.

  2. Microscopy imaging device with advanced imaging properties

    DOE Patents [OSTI]

    Ghosh, Kunal; Burns, Laurie; El Gamal, Abbas; Schnitzer, Mark J.; Cocker, Eric; Ho, Tatt Wei

    2015-11-24

    Systems, methods and devices are implemented for microscope imaging solutions. One embodiment of the present disclosure is directed toward an epifluorescence microscope. The microscope includes an image capture circuit including an array of optical sensor. An optical arrangement is configured to direct excitation light of less than about 1 mW to a target object in a field of view of that is at least 0.5 mm.sup.2 and to direct epi-fluorescence emission caused by the excitation light to the array of optical sensors. The optical arrangement and array of optical sensors are each sufficiently close to the target object to provide at least 2.5 .mu.m resolution for an image of the field of view.

  3. Quantitative luminescence imaging system

    DOE Patents [OSTI]

    Erwin, D.N.; Kiel, J.L.; Batishko, C.R.; Stahl, K.A.

    1990-08-14

    The QLIS images and quantifies low-level chemiluminescent reactions in an electromagnetic field. It is capable of real time nonperturbing measurement and simultaneous recording of many biochemical and chemical reactions such as luminescent immunoassays or enzyme assays. The system comprises image transfer optics, a low-light level digitizing camera with image intensifying microchannel plates, an image process or, and a control computer. The image transfer optics may be a fiber image guide with a bend, or a microscope, to take the light outside of the RF field. Output of the camera is transformed into a localized rate of cumulative digitalized data or enhanced video display or hard-copy images. The system may be used as a luminescent microdosimetry device for radiofrequency or microwave radiation, as a thermal dosimeter, or in the dosimetry of ultra-sound (sonoluminescence) or ionizing radiation. It provides a near-real-time system capable of measuring the extremely low light levels from luminescent reactions in electromagnetic fields in the areas of chemiluminescence assays and thermal microdosimetry, and is capable of near-real-time imaging of the sample to allow spatial distribution analysis of the reaction. It can be used to instrument three distinctly different irradiation configurations, comprising (1) RF waveguide irradiation of a small Petri-dish-shaped sample cell, (2) RF irradiation of samples in a microscope for the microscopic imaging and measurement, and (3) RF irradiation of small to human body-sized samples in an anechoic chamber. 22 figs.

  4. Ferroelectric optical image comparator

    DOE Patents [OSTI]

    Butler, M.A.; Land, C.E.; Martin, S.J.; Pfeifer, K.B.

    1993-11-30

    A ferroelectric optical image comparator has a lead lanthanum zirconate titanate thin-film device which is constructed with a semi-transparent or transparent conductive first electrode on one side of the thin film, a conductive metal second electrode on the other side of the thin film, and the second electrode is in contact with a nonconducting substrate. A photoinduced current in the device represents the dot product between a stored image and an image projected onto the first electrode. One-dimensional autocorrelations are performed by measuring this current while displacing the projected image. 7 figures.

  5. User Science Images

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    in a Field Reverse Configuration (FRC) magnetic field. Magnetic separatrix denoted by green surface. Spheres are colored by azimuthal velocity. Image courtesy of Charlson Kim,...

  6. Quantitative luminescence imaging system

    DOE Patents [OSTI]

    Erwin, David N.; Kiel, Johnathan L.; Batishko, Charles R.; Stahl, Kurt A.

    1990-01-01

    The QLIS images and quantifies low-level chemiluminescent reactions in an electromagnetic field. It is capable of real time nonperturbing measurement and simultaneous recording of many biochemical and chemical reactions such as luminescent immunoassays or enzyme assays. The system comprises image transfer optics, a low-light level digitizing camera with image intensifying microchannel plates, an image process or, and a control computer. The image transfer optics may be a fiber image guide with a bend, or a microscope, to take the light outside of the RF field. Output of the camera is transformed into a localized rate of cumulative digitalized data or enhanced video display or hard-copy images. The system may be used as a luminescent microdosimetry device for radiofrequency or microwave radiation, as a thermal dosimeter, or in the dosimetry of ultra-sound (sonoluminescence) or ionizing radiation. It provides a near-real-time system capable of measuring the extremely low light levels from luminescent reactions in electromagnetic fields in the areas of chemiluminescence assays and thermal microdosimetry, and is capable of near-real-time imaging of the sample to allow spatial distribution analysis of the reaction. It can be used to instrument three distinctly different irradiation configurations, comprising (1) RF waveguide irradiation of a small Petri-dish-shaped sample cell, (2) RF irradiation of samples in a microscope for the microscopie imaging and measurement, and (3) RF irradiation of small to human body-sized samples in an anechoic chamber.

  7. Graphics and Image Standards

    Broader source: Energy.gov [DOE]

    For EERE websites and applications, follow these requirements and best practices for designing graphics and developing images. This includes making them Section 508-compliant.

  8. Environmental Image Gallery

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Create a Sustainable Future Planning for Years to Come Living a Sustainable Future Commitment to Public Involvement Multimedia Google Earth Tours Images Videos Advanced Simulation ...

  9. Ferroelectric optical image comparator

    DOE Patents [OSTI]

    Butler, Michael A.; Land, Cecil E.; Martin, Stephen J.; Pfeifer, Kent B.

    1993-01-01

    A ferroelectric optical image comparator has a lead lanthanum zirconate titanate thin-film device which is constructed with a semi-transparent or transparent conductive first electrode on one side of the thin film, a conductive metal second electrode on the other side of the thin film, and the second electrode is in contact with a nonconducting substrate. A photoinduced current in the device represents the dot product between a stored image and an image projected onto the first electrode. One-dimensional autocorrelations are performed by measuring this current while displacing the projected image.

  10. Fermilab | Press Room | Images

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    When using these images, please credit Fermilab. Return to Press Release Med Res | Hi Res According to the Standard Model of particles and forces, the Higgs mechanism gives...

  11. Fermilab | Press Room | Images

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    using these images, please credit them as specified. Return to Press Release Med Res | Hi Res The Standard Model describes the interactions of the fundamental particle of the...

  12. METALLICITIES, DUST, AND MOLECULAR CONTENT OF A QSO-DAMPED Ly{alpha} SYSTEM REACHING log N(H I) = 22: AN ANALOG TO GRB-DLAs

    SciTech Connect (OSTI)

    Guimaraes, R.; Noterdaeme, P.; Petitjean, P.; Ledoux, C.; Srianand, R.; Rahmani, H.; Lopez, S.

    2012-06-15

    We present the elemental abundance and H{sub 2} content measurements of a damped Ly{alpha} (DLA) system with an extremely large H I column density, log N(H I) (cm{sup -2}) = 22.0 {+-} 0.10, at z{sub abs} = 3.287 toward the QSO SDSS J081634+144612. We measure column densities of H{sub 2}, C I, C I*, Zn II, Fe II, Cr II, Ni II, and Si II from a high signal-to-noise and high spectral resolution VLT-UVES spectrum. The overall metallicity of the system is [Zn/H] = -1.10 {+-} 0.10 relative to solar. Two molecular hydrogen absorption components are seen at z = 3.28667 and 3.28742 (a velocity separation of Almost-Equal-To 52 km s{sup -1}) in rotational levels up to J = 3. We derive a total H{sub 2} column density of log N(H{sub 2}) (cm{sup -2}) = 18.66 and a mean molecular fraction of f = 2N(H{sub 2})/[2N(H{sub 2}) + N(H I)] = 10{sup -3.04{+-}0.37}, typical of known H{sub 2}-bearing DLA systems. From the observed abundance ratios we conclude that dust is present in the interstellar medium of this galaxy, with an enhanced abundance in the H{sub 2}-bearing clouds. However, the total amount of dust along the line of sight is not large and does not produce any significant reddening of the background QSO. The physical conditions in the H{sub 2}-bearing clouds are constrained directly from the column densities of H{sub 2} in different rotational levels, C I and C I*. The kinetic temperature is found to be T Almost-Equal-To 75 K and the particle density lies in the range n{sub H} = 50-80 cm{sup -3}. The neutral hydrogen column density of this DLA is similar to the mean H I column density of DLAs observed at the redshift of {gamma}-ray bursts (GRBs). We explore the relationship between GRB-DLAs and the high column density end of QSO-DLAs finding that the properties (metallicity and depletion) of DLAs with log N(H I) > 21.5 in the two populations do not appear to be significantly different.

  13. Edge-based correlation image registration for multispectral imaging

    DOE Patents [OSTI]

    Nandy, Prabal

    2009-11-17

    Registration information for images of a common target obtained from a plurality of different spectral bands can be obtained by combining edge detection and phase correlation. The images are edge-filtered, and pairs of the edge-filtered images are then phase correlated to produce phase correlation images. The registration information can be determined based on these phase correlation images.

  14. Faulted reservoirs characterization by an image processing technique

    SciTech Connect (OSTI)

    Martinez-Angeles, R.

    1994-12-31

    This paper has developed an image processing method for obtaining the discontinuous areal distribution of oil parameters (formation top, porosity, water saturation,...) of faulted heterogeneous oil reservoirs. For its application it requires the previous knowledge of a set of discrete values z(k,l) from well-logs and seismic profiles. Faulted structures were discretized into continuous structures or blocks bounded by faults. The theoretical fundamental assumption of the proposed method establishes that the natural distributions can be considered as the superposition of several elementary brownian distributions, represented by discrete values z(k,l), whose physical model is the diffusion differential equation and its solution associated. This is a technique that allows the representation of a composed brownian distribution as a linear combination of all elementary brownian functions. For illustrating the operational aspect of brownian analysis, two examples are studied. The results are presented as a digital images by means of an image processing software. This method can be applied in mapping, three dimensions interpolation and reserves calculation of faulted reservoirs.

  15. Fluorescent image tracking velocimeter

    DOE Patents [OSTI]

    Shaffer, Franklin D. (Library, PA)

    1994-01-01

    A multiple-exposure fluorescent image tracking velocimeter (FITV) detects and measures the motion (trajectory, direction and velocity) of small particles close to light scattering surfaces. The small particles may follow the motion of a carrier medium such as a liquid, gas or multi-phase mixture, allowing the motion of the carrier medium to be observed, measured and recorded. The main components of the FITV include: (1) fluorescent particles; (2) a pulsed fluorescent excitation laser source; (3) an imaging camera; and (4) an image analyzer. FITV uses fluorescing particles excited by visible laser light to enhance particle image detectability near light scattering surfaces. The excitation laser light is filtered out before reaching the imaging camera allowing the fluoresced wavelengths emitted by the particles to be detected and recorded by the camera. FITV employs multiple exposures of a single camera image by pulsing the excitation laser light for producing a series of images of each particle along its trajectory. The time-lapsed image may be used to determine trajectory and velocity and the exposures may be coded to derive directional information.

  16. Cathodoluminescence Spectrum Imaging Software

    Energy Science and Technology Software Center (OSTI)

    2011-04-07

    The software developed for spectrum imaging is applied to the analysis of the spectrum series generated by our cathodoluminescence instrumentation. This software provides advanced processing capabilities s such: reconstruction of photon intensity (resolved in energy) and photon energy maps, extraction of the spectrum from selected areas, quantitative imaging mode, pixel-to-pixel correlation spectrum line scans, ASCII, output, filling routines, drift correction, etc.

  17. Medical imaging systems

    DOE Patents [OSTI]

    Frangioni, John V.

    2012-07-24

    A medical imaging system provides simultaneous rendering of visible light and fluorescent images. The system may employ dyes in a small-molecule form that remains in a subject's blood stream for several minutes, allowing real-time imaging of the subject's circulatory system superimposed upon a conventional, visible light image of the subject. The system may also employ dyes or other fluorescent substances associated with antibodies, antibody fragments, or ligands that accumulate within a region of diagnostic significance. In one embodiment, the system provides an excitation light source to excite the fluorescent substance and a visible light source for general illumination within the same optical guide that is used to capture images. In another embodiment, the system is configured for use in open surgical procedures by providing an operating area that is closed to ambient light. More broadly, the systems described herein may be used in imaging applications where a visible light image may be usefully supplemented by an image formed from fluorescent emissions from a fluorescent substance that marks areas of functional interest.

  18. Heart imaging method

    DOE Patents [OSTI]

    Collins, H. Dale; Gribble, R. Parks; Busse, Lawrence J.

    1991-01-01

    A method for providing an image of the human heart's electrical system derives time-of-flight data from an array of EKG electrodes and this data is transformed into phase information. The phase information, treated as a hologram, is reconstructed to provide an image in one or two dimensions of the electrical system of the functioning heart.

  19. Efficient Graffiti Image Retrieval

    SciTech Connect (OSTI)

    Yang, Chunlei; Wong, Pak C.; Ribarsky, William; Fan, Jianping

    2012-07-05

    Research of graffiti character recognition and retrieval, as a branch of traditional optical character recognition (OCR), has started to gain attention in recent years. We have investigated the special challenge of the graffiti image retrieval problem and propose a series of novel techniques to overcome the challenges. The proposed bounding box framework locates the character components in the graffiti images to construct meaningful character strings and conduct image-wise and semantic-wise retrieval on the strings rather than the entire image. Using real world data provided by the law enforcement community to the Pacific Northwest National Laboratory, we show that the proposed framework outperforms the traditional image retrieval framework with better retrieval results and improved computational efficiency.

  20. Confocal coded aperture imaging

    DOE Patents [OSTI]

    Tobin, Jr., Kenneth William (Harriman, TN); Thomas, Jr., Clarence E. (Knoxville, TN)

    2001-01-01

    A method for imaging a target volume comprises the steps of: radiating a small bandwidth of energy toward the target volume; focusing the small bandwidth of energy into a beam; moving the target volume through a plurality of positions within the focused beam; collecting a beam of energy scattered from the target volume with a non-diffractive confocal coded aperture; generating a shadow image of said aperture from every point source of radiation in the target volume; and, reconstructing the shadow image into a 3-dimensional image of the every point source by mathematically correlating the shadow image with a digital or analog version of the coded aperture. The method can comprise the step of collecting the beam of energy scattered from the target volume with a Fresnel zone plate.

  1. Time encoded radiation imaging

    DOE Patents [OSTI]

    Marleau, Peter; Brubaker, Erik; Kiff, Scott

    2014-10-21

    The various technologies presented herein relate to detecting nuclear material at a large stand-off distance. An imaging system is presented which can detect nuclear material by utilizing time encoded imaging relating to maximum and minimum radiation particle counts rates. The imaging system is integrated with a data acquisition system that can utilize variations in photon pulse shape to discriminate between neutron and gamma-ray interactions. Modulation in the detected neutron count rates as a function of the angular orientation of the detector due to attenuation of neighboring detectors is utilized to reconstruct the neutron source distribution over 360 degrees around the imaging system. Neutrons (e.g., fast neutrons) and/or gamma-rays are incident upon scintillation material in the imager, the photons generated by the scintillation material are converted to electrical energy from which the respective neutrons/gamma rays can be determined and, accordingly, a direction to, and the location of, a radiation source identified.

  2. Image forming apparatus

    DOE Patents [OSTI]

    Satoh, Hisao (Hachioji, JP); Haneda, Satoshi (Hachioji, JP); Ikeda, Tadayoshi (Hachioji, JP); Morita, Shizuo (Hachioji, JP); Fukuchi, Masakazu (Hachioji, JP)

    1996-01-01

    In an image forming apparatus having a detachable process cartridge in which an image carrier on which an electrostatic latent image is formed, and a developing unit which develops the electrostatic latent image so that a toner image can be formed, both integrally formed into one unit. There is provided a developer container including a discharge section which can be inserted into a supply opening of the developing unit, and a container in which a predetermined amount of developer is contained, wherein the developer container is provided to the toner supply opening of the developing unit and the developer is supplied into the developing unit housing when a toner stirring screw of the developing unit is rotated.

  3. Adaptive wiener image restoration kernel

    DOE Patents [OSTI]

    Yuan, Ding

    2007-06-05

    A method and device for restoration of electro-optical image data using an adaptive Wiener filter begins with constructing imaging system Optical Transfer Function, and the Fourier Transformations of the noise and the image. A spatial representation of the imaged object is restored by spatial convolution of the image using a Wiener restoration kernel.

  4. Iterative electromagnetic Born inversion applied to earth conductivity imaging

    SciTech Connect (OSTI)

    Alumbaugh, D.L.

    1993-08-01

    This thesis investigates the use of a fast imaging technique to deduce the spatial conductivity distribution in the earth from low frequency (< 1 MHz), cross well electromagnetic (EM) measurements. The theory embodied in this work is the extension of previous strategies and is based on the Born series approximation to solve both the forward and inverse problem. Nonlinear integral equations are employed to derive the series expansion which accounts for the scattered magnetic fields that are generated by inhomogeneities embedded in either a homogenous or a layered earth. A sinusoidally oscillating, vertically oriented magnetic dipole is employed as a source, and it is assumed that the scattering bodies are azimuthally symmetric about the source dipole axis. The use of this model geometry reduces the 3-D vector problem to a more manageable 2-D scalar form. The validity of the cross well EM method is tested by applying the imaging scheme to two sets of field data. Images of the data collected at the Devine, Texas test site show excellent correlation with the well logs. Unfortunately there is a drift error present in the data that limits the accuracy of the results. A more complete set of data collected at the Richmond field station in Richmond, California demonstrates that cross well EM can be successfully employed to monitor the position of an injected mass of salt water. Both the data and the resulting images clearly indicate the plume migrates toward the north-northwest. The plausibility of these conclusions is verified by applying the imaging code to synthetic data generated by a 3-D sheet model.

  5. Polarization transfer NMR imaging

    DOE Patents [OSTI]

    Sillerud, Laurel O.; van Hulsteyn, David B.

    1990-01-01

    A nuclear magnetic resonance (NMR) image is obtained with spatial information modulated by chemical information. The modulation is obtained through polarization transfer from a first element representing the desired chemical, or functional, information, which is covalently bonded and spin-spin coupled with a second element effective to provide the imaging data. First and second rf pulses are provided at first and second frequencies for exciting the imaging and functional elements, with imaging gradients applied therebetween to spatially separate the nuclei response for imaging. The second rf pulse is applied at a time after the first pulse which is the inverse of the spin coupling constant to select the transfer element nuclei which are spin coupled to the functional element nuclei for imaging. In a particular application, compounds such as glucose, lactate, or lactose, can be labeled with .sup.13 C and metabolic processes involving the compounds can be imaged with the sensitivity of .sup.1 H and the selectivity of .sup.13 C.

  6. Advanced Imaging Algorithms for Radiation Imaging Systems

    SciTech Connect (OSTI)

    Marleau, Peter

    2015-10-01

    The intent of the proposed work, in collaboration with University of Michigan, is to develop the algorithms that will bring the analysis from qualitative images to quantitative attributes of objects containing SNM. The first step to achieving this is to develop an indepth understanding of the intrinsic errors associated with the deconvolution and MLEM algorithms. A significant new effort will be undertaken to relate the image data to a posited three-dimensional model of geometric primitives that can be adjusted to get the best fit. In this way, parameters of the model such as sizes, shapes, and masses can be extracted for both radioactive and non-radioactive materials. This model-based algorithm will need the integrated response of a hypothesized configuration of material to be calculated many times. As such, both the MLEM and the model-based algorithm require significant increases in calculation speed in order to converge to solutions in practical amounts of time.

  7. Scanning computed confocal imager

    DOE Patents [OSTI]

    George, John S. (Los Alamos, NM)

    2000-03-14

    There is provided a confocal imager comprising a light source emitting a light, with a light modulator in optical communication with the light source for varying the spatial and temporal pattern of the light. A beam splitter receives the scanned light and direct the scanned light onto a target and pass light reflected from the target to a video capturing device for receiving the reflected light and transferring a digital image of the reflected light to a computer for creating a virtual aperture and outputting the digital image. In a transmissive mode of operation the invention omits the beam splitter means and captures light passed through the target.

  8. Sparse Image Format

    Energy Science and Technology Software Center (OSTI)

    2007-04-12

    The Sparse Image Format (SIF) is a file format for storing spare raster images. It works by breaking an image down into tiles. Space is savid by only storing non-uniform tiles, i.e. tiles with at least two different pixel values. If a tile is completely uniform, its common pixel value is stored instead of the complete tile raster. The software is a library in the C language used for manipulating files in SIF format. Itmore » supports large files (> 2GB) and is designed to build in Windows and Linux environments.« less

  9. Nuclear medicine imaging system

    DOE Patents [OSTI]

    Bennett, G.W.; Brill, A.B.; Bizais, Y.J.C.; Rowe, R.W.; Zubal, I.G.

    1983-03-11

    It is an object of this invention to provide a nuclear imaging system having the versatility to do positron annihilation studies, rotating single or opposed camera gamma emission studies, and orthogonal gamma emission studies. It is a further object of this invention to provide an imaging system having the capability for orthogonal dual multipinhole tomography. It is another object of this invention to provide a nuclear imaging system in which all available energy data, as well as patient physiological data, are acquired simultaneously in list mode.

  10. Lanczos Image Resampling Benchmark

    Energy Science and Technology Software Center (OSTI)

    2007-09-30

    This software abstracts a simple computational kernel from SWarp, an astrometric image resampling code. The input is a grayscale PGM image file (8-bit or 16-bit integer) and the output is a higher-resolution grayscale image file (8-bit or 16-bit integer, or 32-bit floating point). The user selects a scaling factor to be applied and a convolution kernel type to be used during resampling (using 1, 16, 36, 64 input pixels to generate each output pixel). Themore » resampling is performed using the OpenGL API and can run on a PC with GPU (graphics processing unit) hardware.« less

  11. CASL - Image Gallery

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... the heat transfer to the coolant, resulting in a lower efficiency in power production. ... The image on the left shows the fuel temperature contour, and the impact (higher fuel ...

  12. User Science Images

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    after onset of convection overlayed on the AMR grid. Image courtesy of George Pau and John Bell (LBNL). Repo mp111 marcdayhydrogenflame.jpg ASCR: Lab-scale Flame Simulation...

  13. Photothermal imaging scanning microscopy

    DOE Patents [OSTI]

    Chinn, Diane; Stolz, Christopher J.; Wu, Zhouling; Huber, Robert; Weinzapfel, Carolyn

    2006-07-11

    Photothermal Imaging Scanning Microscopy produces a rapid, thermal-based, non-destructive characterization apparatus. Also, a photothermal characterization method of surface and subsurface features includes micron and nanoscale spatial resolution of meter-sized optical materials.

  14. Lensless Imaging of Magnetic Nanostructures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Lensless Imaging of Magnetic Nanostructures Print Magnetism is useful for many devices and techniques, from electric motors and computer hard drives to magnetic resonance imaging...

  15. Lensless Imaging of Magnetic Nanostructures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Imaging of Magnetic Nanostructures Print Magnetism is useful for many devices and techniques, from electric motors and computer hard drives to magnetic resonance imaging used in...

  16. Visualizations Image Gallery

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Visualizations Visualizations Image Gallery Chensantacruz Unusual Death for Ancient Stars chombocrunch2shalehi-res.jpg Resolved Steady-State Flow in Fractured Shale inn-nano-wire-pr-green.png Indium Nitride Nanostructures For More Efficient LEDs combustionmodeling1.jpg Turbulent Combustion Simulations lic-b-427-hr-crop-small.png Turbulence in Solar Wind corecollapserotator2 Explosion Mechanism in Core-Collapse Supernovae OpenMSINERSC.jpg OpenMSI: Mass Spectrometry Images of 3 Lipids Across a

  17. Shifter: User Defined Images

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Shifter: User Defined Images Shifter: User Defined Images Shifter: Bringing Linux containers to HPC NERSC is working to increase flexibility and usability of its HPC systems by enabling Docker-like Linux container technology. Linux containers allow an application to be packaged with its entire software stack - including some portions of the base OS files - as well defining needed user environment variables and application "entry point.". Containers may provide an abstract way of

  18. Reflective optical imaging system

    DOE Patents [OSTI]

    Shafer, David R.

    2000-01-01

    An optical system compatible with short wavelength (extreme ultraviolet) radiation comprising four reflective elements for projecting a mask image onto a substrate. The four optical elements are characterized in order from object to image as convex, concave, convex and concave mirrors. The optical system is particularly suited for step and scan lithography methods. The invention increases the slit dimensions associated with ringfield scanning optics, improves wafer throughput and allows higher semiconductor device density.

  19. Turbine imaging technology assessment

    SciTech Connect (OSTI)

    Moursund, R. A.; Carlson, T. J.

    2004-12-01

    The goal of this project was to identify and evaluate imaging technologies for observing juvenile fish within a Kaplan turbine, and specifically that would enable scientists to determine mechanisms of fish injury within an operating turbine unit. This report documents the opportunities and constraints for observing juvenile fish at specific locations during turbine passage. These observations were used to make modifications to dam structures and operations to improve conditions for fish passage while maintaining or improving hydropower production. The physical and hydraulic environment that fish experience as they pass through the hydroelectric plants were studied and the regions with the greatest potential for injury were defined. Biological response data were also studied to determine the probable types of injuries sustained in the turbine intake and what types of injuries are detectable with imaging technologies. The study grouped injury-causing mechanisms into two categories: fluid (pressure/cavitation, shear, turbulence) and mechanical (strike/collision, grinding/pinching, scraping). The physical constraints of the environment, together with the likely types of injuries to fish, provided the parameters needed for a rigorous imaging technology evaluation. Types of technology evaluated included both tracking and imaging systems using acoustic technologies (such as sonar and acoustic tags) and optic technologies (such as pulsed-laser videography, which is high-speed videography using a laser as the flash). Criteria for determining image data quality such as frame rate, target detectability, and resolution were used to quantify the minimum requirements of an imaging sensor.

  20. Image portion identification methods, image parsing methods, image parsing systems, and articles of manufacture

    DOE Patents [OSTI]

    Lassahn, Gordon D.; Lancaster, Gregory D.; Apel, William A.; Thompson, Vicki S.

    2013-01-08

    Image portion identification methods, image parsing methods, image parsing systems, and articles of manufacture are described. According to one embodiment, an image portion identification method includes accessing data regarding an image depicting a plurality of biological substrates corresponding to at least one biological sample and indicating presence of at least one biological indicator within the biological sample and, using processing circuitry, automatically identifying a portion of the image depicting one of the biological substrates but not others of the biological substrates.

  1. Geothermal Well Logging: Geological Wireline Logs and Fracture...

    Open Energy Info (EERE)

    Course on Geothermal Drilling, Resource Development and Power Plants; Santa Tecla, El Salvador; 20110116 Published Iceland GeoSurvey, 2011 DOI Not Provided Check for DOI...

  2. Interpretation of Flow Logs from Nevada Test Site Boreholes to Estimate Hydraulic conductivity Using Numerical Simulations Constrained by Single-Well Aquifer Tests

    SciTech Connect (OSTI)

    Garcia, C. Amanda; Halford, Keith J.; Laczniak, Randell J.

    2010-02-12

    Hydraulic conductivities of volcanic and carbonate lithologic units at the Nevada Test Site were estimated from flow logs and aquifer-test data. Borehole flow and drawdown were integrated and interpreted using a radial, axisymmetric flow model, AnalyzeHOLE. This integrated approach is used because complex well completions and heterogeneous aquifers and confining units produce vertical flow in the annular space and aquifers adjacent to the wellbore. AnalyzeHOLE simulates vertical flow, in addition to horizontal flow, which accounts for converging flow toward screen ends and diverging flow toward transmissive intervals. Simulated aquifers and confining units uniformly are subdivided by depth into intervals in which the hydraulic conductivity is estimated with the Parameter ESTimation (PEST) software. Between 50 and 150 hydraulic-conductivity parameters were estimated by minimizing weighted differences between simulated and measured flow and drawdown. Transmissivity estimates from single-well or multiple-well aquifer tests were used to constrain estimates of hydraulic conductivity. The distribution of hydraulic conductivity within each lithology had a minimum variance because estimates were constrained with Tikhonov regularization. AnalyzeHOLE simulated hydraulic-conductivity estimates for lithologic units across screened and cased intervals are as much as 100 times less than those estimated using proportional flow-log analyses applied across screened intervals only. Smaller estimates of hydraulic conductivity for individual lithologic units are simulated because sections of the unit behind cased intervals of the wellbore are not assumed to be impermeable, and therefore, can contribute flow to the wellbore. Simulated hydraulic-conductivity estimates vary by more than three orders of magnitude across a lithologic unit, indicating a high degree of heterogeneity in volcanic and carbonate-rock units. The higher water transmitting potential of carbonate-rock units relative to volcanic-rock units is exemplified by the large difference in their estimated maximum hydraulic conductivity; 4,000 and 400 feet per day, respectively. Simulated minimum estimates of hydraulic conductivity are inexact and represent the lower detection limit of the method. Minimum thicknesses of lithologic intervals also were defined for comparing AnalyzeHOLE results to hydraulic properties in regional ground-water flow models.

  3. FOIA_Log_2011.pdf

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

  4. Gamma Log | Open Energy Information

    Open Energy Info (EERE)

    in mining, mineral exploration, water-well drilling, for formation evaluation in oil and gas well drilling and for other related purposes. Different types of rock emit different...

  5. Trip Information Log Tracking System

    Energy Science and Technology Software Center (OSTI)

    1992-06-23

    The system is focused on the Employee Business Travel Event. The system must be able to CRUD (Create, Retrieve, Update, Delete) instances of the Travel Event as well as the ability to CRUD frequent flyer milage associated with airline travel. Additionally the system must provide for a compliance reporting system to monitor reductions in travel costs and lost opportunity costs (i.e., not taking advantage of business class or 7 day advance tickets).

  6. Log in | The Ames Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Primary

  7. IMPROVED V II log(gf) VALUES, HYPERFINE STRUCTURE CONSTANTS, AND ABUNDANCE DETERMINATIONS IN THE PHOTOSPHERES OF THE SUN AND METAL-POOR STAR HD 84937

    SciTech Connect (OSTI)

    Wood, M. P.; Lawler, J. E.; Den Hartog, E. A.; Sneden, C.; Cowan, J. J. E-mail: jelawler@wisc.edu E-mail: chris@verdi.as.utexas.edu

    2014-10-01

    New experimental absolute atomic transition probabilities are reported for 203 lines of V II. Branching fractions are measured from spectra recorded using a Fourier transform spectrometer and an echelle spectrometer. The branching fractions are normalized with radiative lifetime measurements to determine the new transition probabilities. Generally good agreement is found between this work and previously reported V II transition probabilities. Two spectrometers, independent radiometric calibration methods, and independent data analysis routines enable a reduction in systematic uncertainties, in particular those due to optical depth errors. In addition, new hyperfine structure constants are measured for selected levels by least squares fitting line profiles in the FTS spectra. The new V II data are applied to high resolution visible and UV spectra of the Sun and metal-poor star HD 84937 to determine new, more accurate V abundances. Lines covering a range of wavelength and excitation potential are used to search for non-LTE effects. Very good agreement is found between our new solar photospheric V abundance, log ε(V) = 3.95 from 15 V II lines, and the solar-system meteoritic value. In HD 84937, we derive [V/H] = –2.08 from 68 lines, leading to a value of [V/Fe] = 0.24.

  8. AVTA Federal Fleet PEV Readiness Data Logging and Characterization Study for the United States Forest Service: Caribou-Targhee National Forest

    SciTech Connect (OSTI)

    Stephen Schey; Jim Francfort; Ian Nienhueser

    2014-06-01

    Battelle Energy Alliance, LLC, managing and operating contractor for the U.S. Department of Energy’s Idaho National Laboratory, is the lead laboratory for U.S. Department of Energy Advanced Vehicle Testing. Battelle Energy Alliance, LLC contracted with Intertek Testing Services, North America (ITSNA) to collect and evaluate data on federal fleet operations as part of the Advanced Vehicle Testing Activity’s Federal Fleet Vehicle Data Logging and Characterization study. The Advanced Vehicle Testing Activity study seeks to collect and evaluate data to validate the utilization of advanced electric drive vehicle transportation. This report focuses on the Caribou-Targhee National Forest (CTNF) fleet to identify daily operational characteristics of select vehicles and report findings on vehicle and mission characterizations to support the successful introduction of plug-in electric vehicles (PEVs) into the agencies’ fleets. Individual observations of these selected vehicles provide the basis for recommendations related to electric vehicle adoption and whether a battery electric vehicle (BEV) or plug-in hybrid electric vehicle (PHEV) (collectively plug-in electric vehicles, or PEVs) can fulfill the mission requirements. ITSNA acknowledges the support of Idaho National Laboratory and CTNF for participation in the study. ITSNA is pleased to provide this report and is encouraged by enthusiasm and support from the Forest Service and CTNF personnel.

  9. Variable waveband infrared imager

    DOE Patents [OSTI]

    Hunter, Scott R.

    2013-06-11

    A waveband imager includes an imaging pixel that utilizes photon tunneling with a thermally actuated bimorph structure to convert infrared radiation to visible radiation. Infrared radiation passes through a transparent substrate and is absorbed by a bimorph structure formed with a pixel plate. The absorption generates heat which deflects the bimorph structure and pixel plate towards the substrate and into an evanescent electric field generated by light propagating through the substrate. Penetration of the bimorph structure and pixel plate into the evanescent electric field allows a portion of the visible wavelengths propagating through the substrate to tunnel through the substrate, bimorph structure, and/or pixel plate as visible radiation that is proportional to the intensity of the incident infrared radiation. This converted visible radiation may be superimposed over visible wavelengths passed through the imaging pixel.

  10. Microbial Cell Imaging

    SciTech Connect (OSTI)

    Doktycz, Mitchel John; Sullivan, Claretta; Mortensen, Ninell P; Allison, David P

    2011-01-01

    Atomic force microscopy (AFM) is finding increasing application in a variety of fields including microbiology. Until the emergence of AFM, techniques for ivnestigating processes in single microbes were limited. From a biologist's perspective, the fact that AFM can be used to generate high-resolution images in buffers or media is its most appealing feature as live-cell imaging can be pursued. Imaging living cells by AFM allows dynamic biological events to be studied, at the nanoscale, in real time. Few areas of biological research have as much to gain as microbiology from the application of AFM. Whereas the scale of microbes places them near the limit of resolution for light microscopy. AFM is well suited for the study of structures on the order of a micron or less. Although electron microscopy techniques have been the standard for high-resolution imaging of microbes, AFM is quickly gaining favor for several reasons. First, fixatives that impair biological activity are not required. Second, AFM is capable of detecting forces in the pN range, and precise control of the force applied to the cantilever can be maintained. This combination facilitates the evaluation of physical characteristics of microbes. Third, rather than yielding the composite, statistical average of cell populations, as is the case with many biochemical assays, the behavior of single cells can be monitored. Despite the potential of AFM in microbiology, there are several limitations that must be considered. For example, the time required to record an image allows for the study of gross events such as cell division or membrane degradation from an antibiotic but precludes the evaluation of biological reactions and events that happen in just fractions of a second. Additionally, the AFM is a topographical tool and is restricted to imaging surfaces. Therefore, it cannot be used to look inside cells as with opticla and transmission electron microscopes. other practical considerations are the limitation on the maximum scan size (roughly 100 x 100 {mu}m) and the restricted movement of the cantilever in the Z (or height) direction. In most commercial AFMs, the Z range is restricted to roughly 10 {mu}m such that the height of cells to be imaged must be seriously considered. Nevertheless, AFM can provide structural-functional information at nanometer resolution and do so in physiologically relevant environments. Further, instrumentation for scanning probe microscopy continues to advance. Systems for high-speed imaging are becoming available, and techniques for looking inside the cells are being demonstrated. The ability to combine AFM with other imaging modalities is likely to have an even greater impact on microbiological studies. AFM studies of intact microbial cells started to appear in the literature in the 1990s. For example, AFM studies of Saccharomyces cerevisiae examined buddings cars after cell division and detailed changes related to cell growth processes. Also, the first AFM studies of bacterial biofilms appeared. In the late 1990s, AFM studies of intact fungal spores described clear changes in spore surfaces upon germination, and studies of individual bacterial cells were also described. These early bacterial imaging studies examined changes in bacterial morphology due to antimicrobial peptides exposure and bacterial adhesion properties. The majority of these early studies were carried out on dried samples and took advantage of the resolving power of AFM. The lack of cell mounting procedures presented an impediment for cell imaging studies. Subsequently, several approaches to mounting microbial cells have been developed, and these techniques are described later. Also highlighted are general considerations for microbial imaging and a description of some of the various applications of AFM to microbiology.

  11. Multispectral imaging probe

    DOE Patents [OSTI]

    Sandison, David R.; Platzbecker, Mark R.; Descour, Michael R.; Armour, David L.; Craig, Marcus J.; Richards-Kortum, Rebecca

    1999-01-01

    A multispectral imaging probe delivers a range of wavelengths of excitation light to a target and collects a range of expressed light wavelengths. The multispectral imaging probe is adapted for mobile use and use in confined spaces, and is sealed against the effects of hostile environments. The multispectral imaging probe comprises a housing that defines a sealed volume that is substantially sealed from the surrounding environment. A beam splitting device mounts within the sealed volume. Excitation light is directed to the beam splitting device, which directs the excitation light to a target. Expressed light from the target reaches the beam splitting device along a path coaxial with the path traveled by the excitation light from the beam splitting device to the target. The beam splitting device directs expressed light to a collection subsystem for delivery to a detector.

  12. Multispectral imaging probe

    DOE Patents [OSTI]

    Sandison, D.R.; Platzbecker, M.R.; Descour, M.R.; Armour, D.L.; Craig, M.J.; Richards-Kortum, R.

    1999-07-27

    A multispectral imaging probe delivers a range of wavelengths of excitation light to a target and collects a range of expressed light wavelengths. The multispectral imaging probe is adapted for mobile use and use in confined spaces, and is sealed against the effects of hostile environments. The multispectral imaging probe comprises a housing that defines a sealed volume that is substantially sealed from the surrounding environment. A beam splitting device mounts within the sealed volume. Excitation light is directed to the beam splitting device, which directs the excitation light to a target. Expressed light from the target reaches the beam splitting device along a path coaxial with the path traveled by the excitation light from the beam splitting device to the target. The beam splitting device directs expressed light to a collection subsystem for delivery to a detector. 8 figs.

  13. Fluid Imaging of Enhanced Geothermal Systems

    Broader source: Energy.gov [DOE]

    Project objectives: Attempting to Image EGS Fracture & Fluid Networks; Employing joint Geophysical Imaging Technologies.

  14. Turbine Imaging Technology Assessment

    SciTech Connect (OSTI)

    Moursund, Russell A.; Carlson, Thomas J.

    2004-12-31

    The goal of this project was to identify and evaluate imaging alternatives for observing the behavior of juvenile fish within an operating Kaplan turbine unit with a focus on methods to quantify fish injury mechanisms inside an operating turbine unit. Imaging methods are particularly needed to observe the approach and interaction of fish with turbine structural elements. This evaluation documents both the opportunities and constraints for observing juvenile fish at specific locations during turbine passage. The information may be used to acquire the scientific knowledge to make structural improvements and create opportunities for industry to modify turbines and improve fish passage conditions.

  15. Digital Image Correlation Engine

    SciTech Connect (OSTI)

    Turner, Dan; Crozier, Paul; Reu, Phil

    2015-10-06

    DICe is an open source digital image correlation (DIC) tool intended for use as a module in an external application or as a standalone analysis code. It's primary capability is computing full –field displacements and strains from sequences of digital These images are typically of a material sample undergoing a materials characterization experiment, but DICe is also useful for other applications (for example, trajectory tracking). DICe is machine portable (Windows, Linux and Mac) and can be effectively deployed on a high performance computing platform. Capabilities from DICe can be invoked through a library interface, via source code integration of DICe classes or through a graphical user interface.

  16. Magnetic imager and method

    DOE Patents [OSTI]

    Powell, James; Reich, Morris; Danby, Gordon

    1997-07-22

    A magnetic imager 10 includes a generator 18 for practicing a method of applying a background magnetic field over a concealed object, with the object being effective to locally perturb the background field. The imager 10 also includes a sensor 20 for measuring perturbations of the background field to detect the object. In one embodiment, the background field is applied quasi-statically. And, the magnitude or rate of change of the perturbations may be measured for determining location, size, and/or condition of the object.

  17. Magnetic imager and method

    DOE Patents [OSTI]

    Powell, J.; Reich, M.; Danby, G.

    1997-07-22

    A magnetic imager includes a generator for practicing a method of applying a background magnetic field over a concealed object, with the object being effective to locally perturb the background field. The imager also includes a sensor for measuring perturbations of the background field to detect the object. In one embodiment, the background field is applied quasi-statically. And, the magnitude or rate of change of the perturbations may be measured for determining location, size, and/or condition of the object. 25 figs.

  18. Time-Encoded Imagers.

    SciTech Connect (OSTI)

    Marleau, Peter; Brubaker, Erik

    2014-11-01

    This report provides a short overview of the DNN R&D funded project, Time-Encoded Imagers. The project began in FY11 and concluded in FY14. The Project Description below provides the overall motivation and objectives for the project as well as a summary of programmatic direction. It is followed by a short description of each task and the resulting deliverables.

  19. Imaging agents for in vivo magnetic resonance and scintigraphic imaging

    DOE Patents [OSTI]

    Engelstad, Barry L.; Raymond, Kenneth N.; Huberty, John P.; White, David L.

    1991-01-01

    Methods are provided for in vivo magnetic resonance imaging and/or scintigraphic imaging of a subject using chelated transition metal and lanthanide metal complexes. Novel ligands for these complexes are provided.

  20. Imaging agents for in vivo magnetic resonance and scintigraphic imaging

    DOE Patents [OSTI]

    Engelstad, B.L.; Raymond, K.N.; Huberty, J.P.; White, D.L.

    1991-04-23

    Methods are provided for in vivo magnetic resonance imaging and/or scintigraphic imaging of a subject using chelated transition metal and lanthanide metal complexes. Novel ligands for these complexes are provided. No Drawings

  1. Automating Shallow Seismic Imaging

    SciTech Connect (OSTI)

    Steeples, Don W.

    2004-12-09

    This seven-year, shallow-seismic reflection research project had the aim of improving geophysical imaging of possible contaminant flow paths. Thousands of chemically contaminated sites exist in the United States, including at least 3,700 at Department of Energy (DOE) facilities. Imaging technologies such as shallow seismic reflection (SSR) and ground-penetrating radar (GPR) sometimes are capable of identifying geologic conditions that might indicate preferential contaminant-flow paths. Historically, SSR has been used very little at depths shallower than 30 m, and even more rarely at depths of 10 m or less. Conversely, GPR is rarely useful at depths greater than 10 m, especially in areas where clay or other electrically conductive materials are present near the surface. Efforts to image the cone of depression around a pumping well using seismic methods were only partially successful (for complete references of all research results, see the full Final Technical Report, DOE/ER/14826-F), but peripheral results included development of SSR methods for depths shallower than one meter, a depth range that had not been achieved before. Imaging at such shallow depths, however, requires geophone intervals of the order of 10 cm or less, which makes such surveys very expensive in terms of human time and effort. We also showed that SSR and GPR could be used in a complementary fashion to image the same volume of earth at very shallow depths. The primary research focus of the second three-year period of funding was to develop and demonstrate an automated method of conducting two-dimensional (2D) shallow-seismic surveys with the goal of saving time, effort, and money. Tests involving the second generation of the hydraulic geophone-planting device dubbed the ''Autojuggie'' showed that large numbers of geophones can be placed quickly and automatically and can acquire high-quality data, although not under rough topographic conditions. In some easy-access environments, this device could make SSR surveying considerably more efficient and less expensive, particularly when geophone intervals of 25 cm or less are required. The most recent research analyzed the difference in seismic response of the geophones with variable geophone spike length and geophones attached to various steel media. Experiments investigated the azimuthal dependence of the quality of data relative to the orientation of the rigidly attached geophones. Other experiments designed to test the hypothesis that the data are being amplified in much the same way that an organ pipe amplifies sound have so far proved inconclusive. Taken together, the positive results show that SSR imaging within a few meters of the earth's surface is possible if the geology is suitable, that SSR imaging can complement GPR imaging, and that SSR imaging could be made significantly more cost effective, at least in areas where the topography and the geology are favorable. Increased knowledge of the Earth's shallow subsurface through non-intrusive techniques is of potential benefit to management of DOE facilities. Among the most significant problems facing hydrologists today is the delineation of preferential permeability paths in sufficient detail to make a quantitative analysis possible. Aquifer systems dominated by fracture flow have a reputation of being particularly difficult to characterize and model. At chemically contaminated sites, including U.S. Department of Energy (DOE) facilities and others at Department of Defense (DOD) installations worldwide, establishing the spatial extent of the contamination, along with the fate of the contaminants and their transport-flow directions, is essential to the development of effective cleanup strategies. Detailed characterization of the shallow subsurface is important not only in environmental, groundwater, and geotechnical engineering applications, but also in neotectonics, mining geology, and the analysis of petroleum reservoir analogs. Near-surface seismology is in the vanguard of non-intrusive approaches to increase knowledge of the shallow subsurface; our work is a significant departure from conventional seismic-survey field procedures.

  2. Devices, systems, and methods for imaging

    DOE Patents [OSTI]

    Appleby, David; Fraser, Iain; Watson, Scott

    2008-04-15

    Certain exemplary embodiments comprise a system, which can comprise an imaging plate. The imaging plate can be exposable by an x-ray source. The imaging plate can be configured to be used in digital radiographic imaging. The imaging plate can comprise a phosphor-based image storage device configured to convert an image stored therein into light.

  3. ARM - Measurement - Images of Clouds

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Send us a note below or call us at 1-888-ARM-DATA. Send Measurement : Images of Clouds Digital images of cloud scenes (various formats) from satellite, aircraft, and ground-based...

  4. SMB 2014 - Imaging Summer School

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    2014 SMB Imaging Summer School July 11-15 2014 Apply Agenda 2014 SMB Agenda Maps & Directions Visiting SLAC The 1st SSRL SXRMI (Synchrotron X-ray MicroXAS Imaging) School will...

  5. Imaging based refractometers

    DOE Patents [OSTI]

    Baba, Justin S.

    2015-11-24

    Refractometers for simultaneously measuring refractive index of a sample over a range or wavelengths of light include dispersive and focusing optical systems. An optical beam including the rang of wavelengths is spectrally spread along a first axis and focused along a second axis so as to be incident to an interface between the sample and a prism at a range of angles of incidence including a critical angle for at least one wavelength. In some cases, the prism can have a triangle, parallelogram, trapezoid, or other shape. In some cases, the optical beam can be reflected off of multiple interfaces between the prism and the sample. An imaging detector is situated to receive the spectrally spread and focused light from the interface and form an image corresponding to angle of incidence as a function of wavelength. One or more critical angles are indentified and corresponding refractive indices are determined.

  6. Multimode imaging device

    DOE Patents [OSTI]

    Mihailescu, Lucian; Vetter, Kai M

    2013-08-27

    Apparatus for detecting and locating a source of gamma rays of energies ranging from 10-20 keV to several MeV's includes plural gamma ray detectors arranged in a generally closed extended array so as to provide Compton scattering imaging and coded aperture imaging simultaneously. First detectors are arranged in a spaced manner about a surface defining the closed extended array which may be in the form a circle, a sphere, a square, a pentagon or higher order polygon. Some of the gamma rays are absorbed by the first detectors closest to the gamma source in Compton scattering, while the photons that go unabsorbed by passing through gaps disposed between adjacent first detectors are incident upon second detectors disposed on the side farthest from the gamma ray source, where the first spaced detectors form a coded aperture array for two or three dimensional gamma ray source detection.

  7. Digital Image Correlation Engine

    Energy Science and Technology Software Center (OSTI)

    2015-10-06

    DICe is an open source digital image correlation (DIC) tool intended for use as a module in an external application or as a standalone analysis code. It's primary capability is computing full –field displacements and strains from sequences of digital These images are typically of a material sample undergoing a materials characterization experiment, but DICe is also useful for other applications (for example, trajectory tracking). DICe is machine portable (Windows, Linux and Mac) and canmore » be effectively deployed on a high performance computing platform. Capabilities from DICe can be invoked through a library interface, via source code integration of DICe classes or through a graphical user interface.« less

  8. Imaging alpha particle detector

    DOE Patents [OSTI]

    Anderson, David F.

    1985-01-01

    A method and apparatus for detecting and imaging alpha particles sources is described. A conducting coated high voltage electrode (1) and a tungsten wire grid (2) constitute a diode configuration discharge generator for electrons dislodged from atoms or molecules located in between these electrodes when struck by alpha particles from a source (3) to be quantitatively or qualitatively analyzed. A thin polyester film window (4) allows the alpha particles to pass into the gas enclosure and the combination of the glass electrode, grid and window is light transparent such that the details of the source which is imaged with high resolution and sensitivity by the sparks produced can be observed visually as well. The source can be viewed directly, electronically counted or integrated over time using photographic methods. A significant increase in sensitivity over other alpha particle detectors is observed, and the device has very low sensitivity to gamma or beta emissions which might otherwise appear as noise on the alpha particle signal.

  9. Imaging alpha particle detector

    DOE Patents [OSTI]

    Anderson, D.F.

    1980-10-29

    A method and apparatus for detecting and imaging alpha particles sources is described. A dielectric coated high voltage electrode and a tungsten wire grid constitute a diode configuration discharge generator for electrons dislodged from atoms or molecules located in between these electrodes when struck by alpha particles from a source to be quantitatively or qualitatively analyzed. A thin polyester film window allows the alpha particles to pass into the gas enclosure and the combination of the glass electrode, grid and window is light transparent such that the details of the source which is imaged with high resolution and sensitivity by the sparks produced can be observed visually as well. The source can be viewed directly, electronically counted or integrated over time using photographic methods. A significant increase in sensitivity over other alpha particle detectors is observed, and the device has very low sensitivity to gamma or beta emissions which might otherwise appear as noise on the alpha particle signal.

  10. Acoustic imaging microscope

    DOE Patents [OSTI]

    Deason, Vance A.; Telschow, Kenneth L.

    2006-10-17

    An imaging system includes: an object wavefront source and an optical microscope objective all positioned to direct an object wavefront onto an area of a vibrating subject surface encompassed by a field of view of the microscope objective, and to direct a modulated object wavefront reflected from the encompassed surface area through a photorefractive material; and a reference wavefront source and at least one phase modulator all positioned to direct a reference wavefront through the phase modulator and to direct a modulated reference wavefront from the phase modulator through the photorefractive material to interfere with the modulated object wavefront. The photorefractive material has a composition and a position such that interference of the modulated object wavefront and modulated reference wavefront occurs within the photorefractive material, providing a full-field, real-time image signal of the encompassed surface area.

  11. Wake Imaging Measurement System

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Imaging Measurement System - Sandia Energy Energy Search Icon Sandia Home Locations Contact Us Employee Locator Energy & Climate Secure & Sustainable Energy Future Stationary Power Energy Conversion Efficiency Solar Energy Wind Energy Water Power Supercritical CO2 Geothermal Natural Gas Safety, Security & Resilience of the Energy Infrastructure Energy Storage Nuclear Power & Engineering Grid Modernization Battery Testing Nuclear Fuel Cycle Defense Waste Management Programs

  12. Infrared Sky Imager Handbook

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    80 Infrared Sky Imager (IRSI) Instrument Handbook VR Morris March 2016 DISCLAIMER This report was prepared as an account of work sponsored by the U.S. Government. Neither the United States nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned

  13. Medical gamma ray imaging

    DOE Patents [OSTI]

    Osborne, Louis S.; Lanza, Richard C.

    1984-01-01

    A method and apparatus for determining the distribution of a position-emitting radioisotope into an object, the apparatus consisting of a wire mesh radiation converter, an ionizable gas for propagating ionization events caused by electrodes released by the converter, a drift field, a spatial position detector and signal processing circuitry for correlating near-simultaneous ionization events and determining their time differences, whereby the position sources of back-to-back collinear radiation can be located and a distribution image constructed.

  14. Compressive passive millimeter wave imager

    DOE Patents [OSTI]

    Gopalsami, Nachappa; Liao, Shaolin; Elmer, Thomas W; Koehl, Eugene R; Heifetz, Alexander; Raptis, Apostolos C

    2015-01-27

    A compressive scanning approach for millimeter wave imaging and sensing. A Hadamard mask is positioned to receive millimeter waves from an object to be imaged. A subset of the full set of Hadamard acquisitions is sampled. The subset is used to reconstruct an image representing the object.

  15. BT Imaging Pty Ltd | Open Energy Information

    Open Energy Info (EERE)

    Jump to: navigation, search Name: BT Imaging Pty Ltd Place: Sydney, New South Wales, Australia Zip: NSW 2000 Product: BT Imaging designs and develops Luminescence Imaging Systems...

  16. Image registration with uncertainty analysis

    DOE Patents [OSTI]

    Simonson, Katherine M.

    2011-03-22

    In an image registration method, edges are detected in a first image and a second image. A percentage of edge pixels in a subset of the second image that are also edges in the first image shifted by a translation is calculated. A best registration point is calculated based on a maximum percentage of edges matched. In a predefined search region, all registration points other than the best registration point are identified that are not significantly worse than the best registration point according to a predetermined statistical criterion.

  17. Fiducial marker for correlating images

    DOE Patents [OSTI]

    Miller, Lisa Marie; Smith, Randy J.; Warren, John B.; Elliott, Donald

    2011-06-21

    The invention relates to a fiducial marker having a marking grid that is used to correlate and view images produced by different imaging modalities or different imaging and viewing modalities. More specifically, the invention relates to the fiducial marking grid that has a grid pattern for producing either a viewing image and/or a first analytical image that can be overlaid with at least one other second analytical image in order to view a light path or to image different imaging modalities. Depending on the analysis, the grid pattern has a single layer of a certain thickness or at least two layers of certain thicknesses. In either case, the grid pattern is imageable by each imaging or viewing modality used in the analysis. Further, when viewing a light path, the light path of the analytical modality cannot be visualized by viewing modality (e.g., a light microscope objective). By correlating these images, the ability to analyze a thin sample that is, for example, biological in nature but yet contains trace metal ions is enhanced. Specifically, it is desired to analyze both the organic matter of the biological sample and the trace metal ions contained within the biological sample without adding or using extrinsic labels or stains.

  18. Backscatter absorption gas imaging system

    DOE Patents [OSTI]

    McRae, T.G. Jr.

    A video imaging system for detecting hazardous gas leaks. Visual displays of invisible gas clouds are produced by radiation augmentation of the field of view of an imaging device by radiation corresponding to an absorption line of the gas to be detected. The field of view of an imager is irradiated by a laser. The imager receives both backscattered laser light and background radiation. When a detectable gas is present, the backscattered laser light is highly attenuated, producing a region of contrast or shadow on the image. A flying spot imaging system is utilized to synchronously irradiate and scan the area to lower laser power requirements. The imager signal is processed to produce a video display.

  19. Bistatic SAR: Imagery & Image Products.

    SciTech Connect (OSTI)

    Yocky, David A.; Wahl, Daniel E.; Jakowatz, Charles V,

    2014-10-01

    While typical SAR imaging employs a co-located (monostatic) RADAR transmitter and receiver, bistatic SAR imaging separates the transmitter and receiver locations. The transmitter and receiver geometry determines if the scattered signal is back scatter, forward scatter, or side scatter. The monostatic SAR image is backscatter. Therefore, depending on the transmitter/receiver collection geometry, the captured imagery may be quite different that that sensed at the monostatic SAR. This document presents imagery and image products formed from captured signals during the validation stage of the bistatic SAR research. Image quality and image characteristics are discussed first. Then image products such as two-color multi-view (2CMV) and coherent change detection (CCD) are presented.

  20. Confined Space Imager (CSI) Software

    Energy Science and Technology Software Center (OSTI)

    2013-07-03

    The software provides real-time image capture, enhancement, and display, and sensor control for the Confined Space Imager (CSI) sensor system The software captures images over a Cameralink connection and provides the following image enhancements: camera pixel to pixel non-uniformity correction, optical distortion correction, image registration and averaging, and illumination non-uniformity correction. The software communicates with the custom CSI hardware over USB to control sensor parameters and is capable of saving enhanced sensor images to anmore » external USB drive. The software provides sensor control, image capture, enhancement, and display for the CSI sensor system. It is designed to work with the custom hardware.« less

  1. Backscatter absorption gas imaging system

    DOE Patents [OSTI]

    McRae, Jr., Thomas G.

    1985-01-01

    A video imaging system for detecting hazardous gas leaks. Visual displays of invisible gas clouds are produced by radiation augmentation of the field of view of an imaging device by radiation corresponding to an absorption line of the gas to be detected. The field of view of an imager is irradiated by a laser. The imager receives both backscattered laser light and background radiation. When a detectable gas is present, the backscattered laser light is highly attenuated, producing a region of contrast or shadow on the image. A flying spot imaging system is utilized to synchronously irradiate and scan the area to lower laser power requirements. The imager signal is processed to produce a video display.

  2. Fluorescent microthermographic imaging

    SciTech Connect (OSTI)

    Barton, D.L.

    1993-09-01

    In the early days of microelectronics, design rules and feature sizes were large enough that sub-micron spatial resolution was not needed. Infrared or IR thermal techniques were available that calculated the object`s temperature from infrared emission. There is a fundamental spatial resolution limitation dependent on the wavelengths of light being used in the image formation process. As the integrated circuit feature sizes began to shrink toward the one micron level, the limitations imposed on IR thermal systems became more pronounced. Something else was needed to overcome this limitation. Liquid crystals have been used with great success, but they lack the temperature measurement capabilities of other techniques. The fluorescent microthermographic imaging technique (FMI) was developed to meet this need. This technique offers better than 0.01{degrees}C temperature resolution and is diffraction limited to 0.3 {mu}m spatial resolution. While the temperature resolution is comparable to that available on IR systems, the spatial resolution is much better. The FMI technique provides better spatial resolution by using a temperature dependent fluorescent film that emits light at 612 nm instead of the 1.5 {mu}m to 12 {mu}m range used by IR techniques. This tutorial starts with a review of blackbody radiation physics, the process by which all heated objects emit radiation to their surroundings, in order to understand the sources of information that are available to characterize an object`s surface temperature. The processes used in infrared thermal imaging are then detailed to point out the limitations of the technique but also to contrast it with the FMI process. The FMI technique is then described in detail, starting with the fluorescent film physics and ending with a series of examples of past applications of FMI.

  3. Radiation imaging apparatus

    DOE Patents [OSTI]

    Anger, H.O.; Martin, D.C.; Lampton, M.L.

    1983-07-26

    A radiation imaging system using a charge multiplier and a position sensitive anode in the form of periodically arranged sets of interconnected anode regions for detecting the position of the centroid of a charge cloud arriving thereat from the charge multiplier. Various forms of improved position sensitive anodes having single plane electrode connections are disclosed. Various analog and digital signal processing systems are disclosed, including systems which use the fast response of microchannel plates, anodes and preamps to perform scintillation pulse height analysis digitally. 15 figs.

  4. Radiation imaging apparatus

    DOE Patents [OSTI]

    Anger, Hal O.; Martin, Donn C.; Lampton, Michael L.

    1983-01-01

    A radiation imaging system using a charge multiplier and a position sensitive anode in the form of periodically arranged sets of interconnected anode regions for detecting the position of the centroid of a charge cloud arriving thereat from the charge multiplier. Various forms of improved position sensitive anodes having single plane electrode connections are disclosed. Various analog and digital signal processing systems are disclosed, including systems which use the fast response of microchannel plates, anodes and preamps to perform scintillation pulse height analysis digitally.

  5. Multiprocessor computing for images

    SciTech Connect (OSTI)

    Cantoni, V. ); Levialdi, S. )

    1988-08-01

    A review of image processing systems developed until now is given, highlighting the weak points of such systems and the trends that have dictated their evolution through the years producing different generations of machines. Each generation may be characterized by the hardware architecture, the programmability features and the relative application areas. The need for multiprocessing hierarchical systems is discussed focusing on pyramidal architectures. Their computational paradigms, their virtual and physical implementation, their programming and software requirements, and capabilities by means of suitable languages, are discussed.

  6. Superconductive imaging surface magnetometer

    DOE Patents [OSTI]

    Overton, Jr., William C.; van Hulsteyn, David B.; Flynn, Edward R.

    1991-01-01

    An improved pick-up coil system for use with Superconducting Quantum Interference Device gradiometers and magnetometers involving the use of superconducting plates near conventional pick-up coil arrangements to provide imaging of nearby dipole sources and to deflect environmental magnetic noise away from the pick-up coils. This allows the practice of gradiometry and magnetometry in magnetically unshielded environments. One embodiment uses a hemispherically shaped superconducting plate with interior pick-up coils, allowing brain wave measurements to be made on human patients. another embodiment using flat superconducting plates could be used in non-destructive evaluation of materials.

  7. Fourier plane image amplifier

    DOE Patents [OSTI]

    Hackel, Lloyd A.; Hermann, Mark R.; Dane, C. Brent; Tiszauer, Detlev H.

    1995-01-01

    A solid state laser is frequency tripled to 0.3 .mu.m. A small portion of the laser is split off and generates a Stokes seed in a low power oscillator. The low power output passes through a mask with the appropriate hole pattern. Meanwhile, the bulk of the laser output is focused into a larger stimulated Brillouin scattering (SBS) amplifier. The low power beam is directed through the same cell in the opposite direction. The majority of the amplification takes place at the focus which is the fourier transform plane of the mask image. The small holes occupy large area at the focus and thus are preferentially amplified. The amplified output is now imaged onto the multichip module where the holes are drilled. Because of the fourier plane amplifier, only .about.1/10th the power of a competitive system is needed. This concept allows less expensive masks to be used in the process and requires much less laser power.

  8. Fourier plane image amplifier

    DOE Patents [OSTI]

    Hackel, L.A.; Hermann, M.R.; Dane, C.B.; Tiszauer, D.H.

    1995-12-12

    A solid state laser is frequency tripled to 0.3 {micro}m. A small portion of the laser is split off and generates a Stokes seed in a low power oscillator. The low power output passes through a mask with the appropriate hole pattern. Meanwhile, the bulk of the laser output is focused into a larger stimulated Brillouin scattering (SBS) amplifier. The low power beam is directed through the same cell in the opposite direction. The majority of the amplification takes place at the focus which is the fourier transform plane of the mask image. The small holes occupy large area at the focus and thus are preferentially amplified. The amplified output is now imaged onto the multichip module where the holes are drilled. Because of the fourier plane amplifier, only about 1/10th the power of a competitive system is needed. This concept allows less expensive masks to be used in the process and requires much less laser power. 1 fig.

  9. Staring 2-D hadamard transform spectral imager

    DOE Patents [OSTI]

    Gentry, Stephen M.; Wehlburg, Christine M.; Wehlburg, Joseph C.; Smith, Mark W.; Smith, Jody L.

    2006-02-07

    A staring imaging system inputs a 2D spatial image containing multi-frequency spectral information. This image is encoded in one dimension of the image with a cyclic Hadamarid S-matrix. The resulting image is detecting with a spatial 2D detector; and a computer applies a Hadamard transform to recover the encoded image.

  10. T-R Cycle Characterization and Imaging: Advanced Diagnostic Methodology for Petroleum Reservoir and Trap Detection and Delineation

    SciTech Connect (OSTI)

    Ernest A. Mancini

    2006-08-30

    Characterization of stratigraphic sequences (T-R cycles or sequences) included outcrop studies, well log analysis and seismic reflection interpretation. These studies were performed by researchers at the University of Alabama, Wichita State University and McGill University. The outcrop, well log and seismic characterization studies were used to develop a depositional sequence model, a T-R cycle (sequence) model, and a sequence stratigraphy predictive model. The sequence stratigraphy predictive model developed in this study is based primarily on the modified T-R cycle (sequence) model. The T-R cycle (sequence) model using transgressive and regressive systems tracts and aggrading, backstepping, and infilling intervals or sections was found to be the most appropriate sequence stratigraphy model for the strata in the onshore interior salt basins of the Gulf of Mexico to improve petroleum stratigraphic trap and specific reservoir facies imaging, detection and delineation. The known petroleum reservoirs of the Mississippi Interior and North Louisiana Salt Basins were classified using T-R cycle (sequence) terminology. The transgressive backstepping reservoirs have been the most productive of oil, and the transgressive backstepping and regressive infilling reservoirs have been the most productive of gas. Exploration strategies were formulated using the sequence stratigraphy predictive model and the classification of the known petroleum reservoirs utilizing T-R cycle (sequence) terminology. The well log signatures and seismic reflector patterns were determined to be distinctive for the aggrading, backstepping and infilling sections of the T-R cycle (sequence) and as such, well log and seismic data are useful for recognizing and defining potential reservoir facies. The use of the sequence stratigraphy predictive model, in combination with the knowledge of how the distinctive characteristics of the T-R system tracts and their subdivisions are expressed in well log patterns and seismic reflection configurations and terminations, improves the ability to identify and define the limits of potential stratigraphic traps and the stratigraphic component of combination stratigraphic and structural traps and the associated continental, coastal plain and marine potential reservoir facies. The assessment of the underdeveloped and undiscovered reservoirs and resources in the Mississippi Interior and North Louisiana Salt Basins resulted in the confirmation of the Monroe Uplift as a feature characterized by a major regional unconformity, which serves as a combination stratigraphic and structural trap with a significant stratigraphic component, and the characterization of a developing play in southwest Alabama, which involves a stratigraphic trap, located updip near the pinchout of the potential reservoir facies. Potential undiscovered and underdeveloped reservoirs in the onshore interior salt basins are identified as Jurassic and Cretaceous aggrading continental and coastal, backstepping nearshore marine and marine shelf, and infilling fluvial, deltaic, coastal plain and marine shelf.

  11. Device for wavelength-selective imaging

    DOE Patents [OSTI]

    Frangioni, John V.

    2010-09-14

    An imaging device captures both a visible light image and a diagnostic image, the diagnostic image corresponding to emissions from an imaging medium within the object. The visible light image (which may be color or grayscale) and the diagnostic image may be superimposed to display regions of diagnostic significance within a visible light image. A number of imaging media may be used according to an intended application for the imaging device, and an imaging medium may have wavelengths above, below, or within the visible light spectrum. The devices described herein may be advantageously packaged within a single integrated device or other solid state device, and/or employed in an integrated, single-camera medical imaging system, as well as many non-medical imaging systems that would benefit from simultaneous capture of visible-light wavelength images along with images at other wavelengths.

  12. Image-based occupancy sensor

    DOE Patents [OSTI]

    Polese, Luigi Gentile; Brackney, Larry

    2015-05-19

    An image-based occupancy sensor includes a motion detection module that receives and processes an image signal to generate a motion detection signal, a people detection module that receives the image signal and processes the image signal to generate a people detection signal, a face detection module that receives the image signal and processes the image signal to generate a face detection signal, and a sensor integration module that receives the motion detection signal from the motion detection module, receives the people detection signal from the people detection module, receives the face detection signal from the face detection module, and generates an occupancy signal using the motion detection signal, the people detection signal, and the face detection signal, with the occupancy signal indicating vacancy or occupancy, with an occupancy indication specifying that one or more people are detected within the monitored volume.

  13. Document Imaging | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Document Imaging Document Imaging Converting Paper Documents into Electronic Files Converting paper documents into electronic files helps us manage, store, access and archive the organizational information we have "locked up" in paper documents. Utilizing high-quality document scanners, a top-end six-engine Optical Character Recognition (OCR) system and maintaining Quality Controls to provide a successful Imaging solution. Once converted, these electronic files can be indexed and

  14. X-ray Imaging Workshop

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Imaging and Spectro-microscopy: the Present and the Future Stanford Synchrotron Radiation Laboratory October 8-9, 2002 Organizers: John Miao & Keith Hodgson A workshop on "X-ray Imaging and Spectro-microscopy: the Present and the Future" was held on October 8-9, 2002. This workshop, organized by John Miao (SSRL) and Keith Hodgson (SSRL) provided a forum to discuss the scientific applications of a variety of imaging and spectro-microscopic techniques, including photoemission

  15. Multiple-image oscilloscope camera

    DOE Patents [OSTI]

    Yasillo, Nicholas J.

    1978-01-01

    An optical device for placing automatically a plurality of images at selected locations on one film comprises a stepping motor coupled to a rotating mirror and lens. A mechanical connection from the mirror controls an electronic logical system to allow rotation of the mirror to place a focused image at the desired preselected location. The device is of especial utility when used to place four images on a single film to record oscilloscope views obtained in gamma radiography.

  16. Lensless Imaging of Magnetic Nanostructures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Lensless Imaging of Magnetic Nanostructures Print Magnetism is useful for many devices and techniques, from electric motors and computer hard drives to magnetic resonance imaging used in medicine. By studying the basics of magnetism, scientists aim to better understand the fundamental physical principles that govern magnetic systems, perhaps leading to important new technologies. The high brightness and coherence of the ALS's soft x-rays have enabled scientists to apply lensless x-ray imaging

  17. Lensless Imaging of Magnetic Nanostructures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Lensless Imaging of Magnetic Nanostructures Print Magnetism is useful for many devices and techniques, from electric motors and computer hard drives to magnetic resonance imaging used in medicine. By studying the basics of magnetism, scientists aim to better understand the fundamental physical principles that govern magnetic systems, perhaps leading to important new technologies. The high brightness and coherence of the ALS's soft x-rays have enabled scientists to apply lensless x-ray imaging

  18. Lensless Imaging of Magnetic Nanostructures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Lensless Imaging of Magnetic Nanostructures Print Magnetism is useful for many devices and techniques, from electric motors and computer hard drives to magnetic resonance imaging used in medicine. By studying the basics of magnetism, scientists aim to better understand the fundamental physical principles that govern magnetic systems, perhaps leading to important new technologies. The high brightness and coherence of the ALS's soft x-rays have enabled scientists to apply lensless x-ray imaging

  19. Lensless Imaging of Magnetic Nanostructures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Lensless Imaging of Magnetic Nanostructures Print Magnetism is useful for many devices and techniques, from electric motors and computer hard drives to magnetic resonance imaging used in medicine. By studying the basics of magnetism, scientists aim to better understand the fundamental physical principles that govern magnetic systems, perhaps leading to important new technologies. The high brightness and coherence of the ALS's soft x-rays have enabled scientists to apply lensless x-ray imaging

  20. Lensless Imaging of Magnetic Nanostructures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Lensless Imaging of Magnetic Nanostructures Lensless Imaging of Magnetic Nanostructures Print Wednesday, 28 March 2012 00:00 Magnetism is useful for many devices and techniques, from electric motors and computer hard drives to magnetic resonance imaging used in medicine. By studying the basics of magnetism, scientists aim to better understand the fundamental physical principles that govern magnetic systems, perhaps leading to important new technologies. The high brightness and coherence of the

  1. Lensless Imaging of Magnetic Nanostructures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Imaging of Magnetic Nanostructures Print Magnetism is useful for many devices and techniques, from electric motors and computer hard drives to magnetic resonance imaging used in medicine. By studying the basics of magnetism, scientists aim to better understand the fundamental physical principles that govern magnetic systems, perhaps leading to important new technologies. The high brightness and coherence of the ALS's soft x-rays have enabled scientists to apply lensless x-ray imaging for the

  2. Lensless Imaging of Magnetic Nanostructures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Imaging of Magnetic Nanostructures Print Magnetism is useful for many devices and techniques, from electric motors and computer hard drives to magnetic resonance imaging used in medicine. By studying the basics of magnetism, scientists aim to better understand the fundamental physical principles that govern magnetic systems, perhaps leading to important new technologies. The high brightness and coherence of the ALS's soft x-rays have enabled scientists to apply lensless x-ray imaging for the

  3. Lensless Imaging of Magnetic Nanostructures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Lensless Imaging of Magnetic Nanostructures Print Magnetism is useful for many devices and techniques, from electric motors and computer hard drives to magnetic resonance imaging used in medicine. By studying the basics of magnetism, scientists aim to better understand the fundamental physical principles that govern magnetic systems, perhaps leading to important new technologies. The high brightness and coherence of the ALS's soft x-rays have enabled scientists to apply lensless x-ray imaging

  4. Lensless Imaging of Magnetic Nanostructures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Lensless Imaging of Magnetic Nanostructures Print Magnetism is useful for many devices and techniques, from electric motors and computer hard drives to magnetic resonance imaging used in medicine. By studying the basics of magnetism, scientists aim to better understand the fundamental physical principles that govern magnetic systems, perhaps leading to important new technologies. The high brightness and coherence of the ALS's soft x-rays have enabled scientists to apply lensless x-ray imaging

  5. Acoustic imaging system

    DOE Patents [OSTI]

    Smith, Richard W.

    1979-01-01

    An acoustic imaging system for displaying an object viewed by a moving array of transducers as the array is pivoted about a fixed point within a given plane. A plurality of transducers are fixedly positioned and equally spaced within a laterally extending array and operatively directed to transmit and receive acoustic signals along substantially parallel transmission paths. The transducers are sequentially activated along the array to transmit and receive acoustic signals according to a preestablished sequence. Means are provided for generating output voltages for each reception of an acoustic signal, corresponding to the coordinate position of the object viewed as the array is pivoted. Receptions from each of the transducers are presented on the same display at coordinates corresponding to the actual position of the object viewed to form a plane view of the object scanned.

  6. Lensless Imaging of Magnetic Nanostructures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Print Magnetism is useful for many devices and techniques, from electric motors and computer hard drives to magnetic resonance imaging used in medicine. By studying...

  7. Lensless Imaging of Magnetic Nanostructures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    useful for many devices and techniques, from electric motors and computer hard drives to magnetic resonance imaging used in medicine. By studying the basics of magnetism,...

  8. Multispectral Imaging | Open Energy Information

    Open Energy Info (EERE)

    ASTER imager utilizes 14 bands that cover portions of the visible (green, yellow, and red), near infrared (NIR), short wavelength infrared (SWIR), and long wavelength infrared...

  9. Sandia Wake-Imaging System

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Nuclear Power & Engineering Grid Modernization Battery Testing Nuclear Fuel Cycle Defense Waste Management Programs ... Sandia Wake-Imaging System HomeTag:Sandia ...

  10. High-resolution ophthalmic imaging system

    DOE Patents [OSTI]

    Olivier, Scot S. (Livermore, CA); Carrano, Carmen J. (Livermore, CA)

    2007-12-04

    A system for providing an improved resolution retina image comprising an imaging camera for capturing a retina image and a computer system operatively connected to the imaging camera, the computer producing short exposures of the retina image and providing speckle processing of the short exposures to provide the improved resolution retina image. The system comprises the steps of capturing a retina image, producing short exposures of the retina image, and speckle processing the short exposures of the retina image to provide the improved resolution retina image.

  11. Imaging synthetic aperture radar

    DOE Patents [OSTI]

    Burns, Bryan L.; Cordaro, J. Thomas

    1997-01-01

    A linear-FM SAR imaging radar method and apparatus to produce a real-time image by first arranging the returned signals into a plurality of subaperture arrays, the columns of each subaperture array having samples of dechirped baseband pulses, and further including a processing of each subaperture array to obtain coarse-resolution in azimuth, then fine-resolution in range, and lastly, to combine the processed subapertures to obtain the final fine-resolution in azimuth. Greater efficiency is achieved because both the transmitted signal and a local oscillator signal mixed with the returned signal can be varied on a pulse-to-pulse basis as a function of radar motion. Moreover, a novel circuit can adjust the sampling location and the A/D sample rate of the combined dechirped baseband signal which greatly reduces processing time and hardware. The processing steps include implementing a window function, stabilizing either a central reference point and/or all other points of a subaperture with respect to doppler frequency and/or range as a function of radar motion, sorting and compressing the signals using a standard fourier transforms. The stabilization of each processing part is accomplished with vector multiplication using waveforms generated as a function of radar motion wherein these waveforms may be synthesized in integrated circuits. Stabilization of range migration as a function of doppler frequency by simple vector multiplication is a particularly useful feature of the invention; as is stabilization of azimuth migration by correcting for spatially varying phase errors prior to the application of an autofocus process.

  12. Image subregion querying using color correlograms

    DOE Patents [OSTI]

    Huang, Jing; Kumar, Shanmugasundaram Ravi; Mitra, Mandar; Zhu, Wei-Jing

    2002-01-01

    A color correlogram (10) is a representation expressing the spatial correlation of color and distance between pixels in a stored image. The color correlogram (10) may be used to distinguish objects in an image as well as between images in a plurality of images. By intersecting a color correlogram of an image object with correlograms of images to be searched, those images which contain the objects are identified by the intersection correlogram.

  13. Video surveillance with speckle imaging

    DOE Patents [OSTI]

    Carrano, Carmen J.; Brase, James M.

    2007-07-17

    A surveillance system looks through the atmosphere along a horizontal or slant path. Turbulence along the path causes blurring. The blurring is corrected by speckle processing short exposure images recorded with a camera. The exposures are short enough to effectively freeze the atmospheric turbulence. Speckle processing is used to recover a better quality image of the scene.

  14. Nuclear medicine imaging system

    DOE Patents [OSTI]

    Bennett, Gerald W.; Brill, A. Bertrand; Bizais, Yves J. C.; Rowe, R. Wanda; Zubal, I. George

    1986-01-01

    A nuclear medicine imaging system having two large field of view scintillation cameras mounted on a rotatable gantry and being movable diametrically toward or away from each other is disclosed. In addition, each camera may be rotated about an axis perpendicular to the diameter of the gantry. The movement of the cameras allows the system to be used for a variety of studies, including positron annihilation, and conventional single photon emission, as well as static orthogonal dual multi-pinhole tomography. In orthogonal dual multi-pinhole tomography, each camera is fitted with a seven pinhole collimator to provide seven views from slightly different perspectives. By using two cameras at an angle to each other, improved sensitivity and depth resolution is achieved. The computer system and interface acquires and stores a broad range of information in list mode, including patient physiological data, energy data over the full range detected by the cameras, and the camera position. The list mode acquisition permits the study of attenuation as a result of Compton scatter, as well as studies involving the isolation and correlation of energy with a range of physiological conditions.

  15. Reaction product imaging

    SciTech Connect (OSTI)

    Chandler, D.W.

    1993-12-01

    Over the past few years the author has investigated the photochemistry of small molecules using the photofragment imaging technique. Bond energies, spectroscopy of radicals, dissociation dynamics and branching ratios are examples of information obtained by this technique. Along with extending the technique to the study of bimolecular reactions, efforts to make the technique as quantitative as possible have been the focus of the research effort. To this end, the author has measured the bond energy of the C-H bond in acetylene, branching ratios in the dissociation of HI, the energetics of CH{sub 3}Br, CD{sub 3}Br, C{sub 2}H{sub 5}Br and C{sub 2}H{sub 5}OBr dissociation, and the alignment of the CD{sub 3} fragment from CD{sub 3}I photolysis. In an effort to extend the technique to bimolecular reactions the author has studied the reaction of H with HI and the isotopic exchange reaction between H and D{sub 2}.

  16. Simultaneous acquisition of differing image types

    DOE Patents [OSTI]

    Demos, Stavros G

    2012-10-09

    A system in one embodiment includes an image forming device for forming an image from an area of interest containing different image components; an illumination device for illuminating the area of interest with light containing multiple components; at least one light source coupled to the illumination device, the at least one light source providing light to the illumination device containing different components, each component having distinct spectral characteristics and relative intensity; an image analyzer coupled to the image forming device, the image analyzer decomposing the image formed by the image forming device into multiple component parts based on type of imaging; and multiple image capture devices, each image capture device receiving one of the component parts of the image. A method in one embodiment includes receiving an image from an image forming device; decomposing the image formed by the image forming device into multiple component parts based on type of imaging; receiving the component parts of the image; and outputting image information based on the component parts of the image. Additional systems and methods are presented.

  17. Image indexing using color correlograms

    DOE Patents [OSTI]

    Huang, Jing; Kumar, Shanmugasundaram Ravi; Mitra, Mandar; Zhu, Wei-Jing

    2001-01-01

    A color correlogram is a three-dimensional table indexed by color and distance between pixels which expresses how the spatial correlation of color changes with distance in a stored image. The color correlogram may be used to distinguish an image from other images in a database. To create a color correlogram, the colors in the image are quantized into m color values, c.sub.i . . . c.sub.m. Also, the distance values k.epsilon.[d] to be used in the correlogram are determined where [d] is the set of distances between pixels in the image, and where dmax is the maximum distance measurement between pixels in the image. Each entry (i, j, k) in the table is the probability of finding a pixel of color c.sub.i at a selected distance k from a pixel of color c.sub.i. A color autocorrelogram, which is a restricted version of the color correlogram that considers color pairs of the form (i,i) only, may also be used to identify an image.

  18. Imaging radiation detector with gain

    DOE Patents [OSTI]

    Morris, C.L.; Idzorek, G.C.; Atencio, L.G.

    1982-07-21

    A radiation imaging device which has application in x-ray imaging. The device can be utilized in CAT scanners and other devices which require high sensitivity and low x-ray fluxes. The device utilizes cumulative multiplication of charge carriers on the anode plane and the collection of positive ion charges to image the radiation intensity on the cathode plane. Parallel and orthogonal cathode wire arrays are disclosed as well as a two-dimensional grid pattern for collecting the positive ions on the cathode.

  19. Imaging radiation detector with gain

    DOE Patents [OSTI]

    Morris, Christopher L.; Idzorek, George C.; Atencio, Leroy G.

    1984-01-01

    A radiation imaging device which has application in x-ray imaging. The device can be utilized in CAT scanners and other devices which require high sensitivity and low x-ray fluxes. The device utilizes cumulative multiplication of charge carriers on the anode plane and the collection of positive ion charges to image the radiation intensity on the cathode plane. Parallel and orthogonal cathode wire arrays are disclosed as well as a two-dimensional grid pattern for collecting the positive ions on the cathode.

  20. Contactless Electroluminescence Imaging for Cell and Module

    Office of Scientific and Technical Information (OSTI)

    Characterization (Conference) | SciTech Connect Contactless Electroluminescence Imaging for Cell and Module Characterization Citation Details In-Document Search Title: Contactless Electroluminescence Imaging for Cell and Module Characterization Module performance can be characterized by imaging using baseline and periodic images to track defects and degradation. Both thermal images, which can be acquired during sunny operating conditions, and photoluminescence images, which could be acquired

  1. Imaging Liquids Using Microfluidic Cells

    SciTech Connect (OSTI)

    Yu, Xiao-Ying; Liu, Bingwen; Yang, Li

    2013-05-10

    Chemistry occurring in the liquid and liquid surface is important in many applications. Chemical imaging of liquids using vacuum based analytical techniques is challenging due to the difficulty in working with liquids with high volatility. Recent development in microfluidics enabled and increased our capabilities to study liquid in situ using surface sensitive techniques such as electron microscopy and spectroscopy. Due to its small size, low cost, and flexibility in design, liquid cells based on microfluidics have been increasingly used in studying and imaging complex phenomena involving liquids. This paper presents a review of microfluidic cells that were developed to adapt to electron microscopes and various spectrometers for in situ chemical analysis and imaging of liquids. The following topics will be covered including cell designs, fabrication techniques, unique technical features for vacuum compatible cells, and imaging with electron microscopy and spectroscopy. Challenges are summarized and recommendations for future development priority are proposed.

  2. High speed imaging television system

    DOE Patents [OSTI]

    Wilkinson, William O.; Rabenhorst, David W.

    1984-01-01

    A television system for observing an event which provides a composite video output comprising the serially interlaced images the system is greater than the time resolution of any of the individual cameras.

  3. Imaging atoms in 3-D

    ScienceCinema (OSTI)

    Ercius, Peter

    2014-06-27

    Berkeley Lab's Peter Ercius discusses "Imaging atoms in 3-D" in this Oct. 28, 2013 talk, which is part of a Science at the Theater event entitled Eight Big Ideas

  4. Lensless Imaging of Magnetic Nanostructures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    to detect the state of your image in the mirror (reflection). If you are an ALS scientist, perhaps you go to work and shine some x-ray light on a crystal to detect the...

  5. Sandia National Laboratories: News: Image Gallery

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Image Gallery Members of the media are welcome to download and use these images. Please credit either the photographer or Sandia National Laboratories

  6. Plant Metabolic Imaging | The Ames Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Plant Metabolic Imaging The Ames Laboratory has developed state-of-the-art processes for imaging plant metabolites. Identifying and understanding plant chemicals will lead to the...

  7. Sandia National Laboratories: News: Image Gallery

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Image Gallery Members of the media are welcome to download and use these images. Please credit either the photographer or Sandia National Laboratories.

  8. Nanoscale Chemical Imaging of a Working Catalyst

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Nanoscale Chemical Imaging of a Working Catalyst Nanoscale Chemical Imaging of a Working Catalyst Print Wednesday, 28 January 2009 00:00 The heterogeneous catalysts used in most ...

  9. Direct Imaging of Asymmetric Magnetization Reversal

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Direct Imaging of Asymmetric Magnetization Reversal Direct Imaging of Asymmetric Magnetization Reversal Print Wednesday, 28 September 2005 00:00 The phenomenon of exchange bias has...

  10. Help:Linked images | Open Energy Information

    Open Energy Info (EERE)

    Linked images Redirect page Jump to: navigation, search REDIRECT Manual:Linked images Retrieved from "http:en.openei.orgwindex.php?titleHelp:Linkedimages&oldid58478" ...

  11. Multispectral Imaging At Yellowstone Region (Hellman & Ramsey...

    Open Energy Info (EERE)

    Region Exploration Technique Multispectral Imaging Activity Date Spectral Imaging Sensor ASTER Usefulness useful DOE-funding Unknown Notes ASTER References Melanie J. Hellman,...

  12. Hyperspectral Imaging At Yellowstone Region (Hellman & Ramsey...

    Open Energy Info (EERE)

    Region Exploration Technique Hyperspectral Imaging Activity Date Spectral Imaging Sensor AVIRIS Usefulness useful DOE-funding Unknown Notes AVIRIS airborne hyperspectral...

  13. Widget:Background-Image | Open Energy Information

    Open Energy Info (EERE)

    Edit History Widget:Background-Image Jump to: navigation, search MHK Instrumentation & Sensor Database pages use this widget to load device images as CSS background rather than...

  14. Radiopharmaceuticals for imaging the heart

    DOE Patents [OSTI]

    Green, M.A.; Tsang, B.W.

    1994-06-28

    Radiopharmaceuticals for imaging myocardial tissues are prepared by forming lipophilic, cationic complexes of radioactive metal ions with metal chelating ligands comprising the Schiff base adducts of triamines and tetraamines with optionally substituted salicylaldehydes. The lipophilic, cationic, radioactive complexes of the invention exhibit high uptake and retention in myocardial tissues. Preferred gallium-68(III) complexes in accordance with this invention can be used to image the heart using positron emission tomography. 6 figures.

  15. Range determination for scannerless imaging

    DOE Patents [OSTI]

    Muguira, Maritza Rosa; Sackos, John Theodore; Bradley, Bart Davis; Nellums, Robert

    2000-01-01

    A new method of operating a scannerless range imaging system (e.g., a scannerless laser radar) has been developed. This method is designed to compensate for nonlinear effects which appear in many real-world components. The system operates by determining the phase shift of the laser modulation, which is a physical quantity related physically to the path length between the laser source and the detector, for each pixel of an image.

  16. Radiopharmaceuticals for imaging the heart

    DOE Patents [OSTI]

    Green, Mark A.; Tsang, Brenda W.

    1994-01-01

    Radiopharmaceuticals for imaging myocardial tissues are prepared by forming lipophilic, cationic complexes of radioactive metal ions with metal chelating ligands comprising the Schiff base adducts of triamines and tetraamines with optionally substituted salicylaldehydes. The lipophilic, cationic, radioactive complexes of the invention exhibit high uptake and retention in myocardial tissues. Preferred gallium-68(III) complexes in accordance with this invention can be used to image the heart using positron emission tomography.

  17. HAWC Observatory captures first image

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    HAWC Observatory captures first image HAWC Observatory captures first image The facility is designed to detect cosmic rays and the highest energy gamma rays ever observed from astrophysical sources. April 30, 2013 The High-Altitude Water Cherenkov (HAWC) Observatory is under construction. The High-Altitude Water Cherenkov (HAWC) Observatory is under construction. HAWC is under construction inside the Parque Nacional Pico de Orizaba, a Mexican national park. An international team of researchers,

  18. Image Composition Engine for Tiles

    Energy Science and Technology Software Center (OSTI)

    2011-08-22

    The Image Composition Engine for Tiles (lceT) is a high-performance sort-last parallel rendering library. It is designed to be used in parallel applications requiring rendering. The primary purpose of IceT is to be integrated into parallel visualization applications such as ParaView to provide parallel rendering capabilities. The Image Composition Engine for Tiles (lceT) is a high-performance sort-last parallel rendering library. IceT uses a "sort-Iasf' approach to rendering. Each process in a parallel application independently rendersmore » a local piece of geometry. The resulting images are given to IceT, and IceT combines the images together to form a single cohesive image. Ice T is also capable of driving tiled displays, largeformat displays comprising an array of smaller displays. To this end IceT can collect the smaller tile images and organize them such that the entire tiled display can be driven. Ice T takes advantage of spatial coherence in geometry by identifying empty regions of the display and reducing the overall required work.« less

  19. High speed imager test station

    DOE Patents [OSTI]

    Yates, George J.; Albright, Kevin L.; Turko, Bojan T.

    1995-01-01

    A test station enables the performance of a solid state imager (herein called a focal plane array or FPA) to be determined at high image frame rates. A programmable waveform generator is adapted to generate clock pulses at determinable rates for clock light-induced charges from a FPA. The FPA is mounted on an imager header board for placing the imager in operable proximity to level shifters for receiving the clock pulses and outputting pulses effective to clock charge from the pixels forming the FPA. Each of the clock level shifters is driven by leading and trailing edge portions of the clock pulses to reduce power dissipation in the FPA. Analog circuits receive output charge pulses clocked from the FPA pixels. The analog circuits condition the charge pulses to cancel noise in the pulses and to determine and hold a peak value of the charge for digitizing. A high speed digitizer receives the peak signal value and outputs a digital representation of each one of the charge pulses. A video system then displays an image associated with the digital representation of the output charge pulses clocked from the FPA. In one embodiment, the FPA image is formatted to a standard video format for display on conventional video equipment.

  20. High speed imager test station

    DOE Patents [OSTI]

    Yates, G.J.; Albright, K.L.; Turko, B.T.

    1995-11-14

    A test station enables the performance of a solid state imager (herein called a focal plane array or FPA) to be determined at high image frame rates. A programmable waveform generator is adapted to generate clock pulses at determinable rates for clock light-induced charges from a FPA. The FPA is mounted on an imager header board for placing the imager in operable proximity to level shifters for receiving the clock pulses and outputting pulses effective to clock charge from the pixels forming the FPA. Each of the clock level shifters is driven by leading and trailing edge portions of the clock pulses to reduce power dissipation in the FPA. Analog circuits receive output charge pulses clocked from the FPA pixels. The analog circuits condition the charge pulses to cancel noise in the pulses and to determine and hold a peak value of the charge for digitizing. A high speed digitizer receives the peak signal value and outputs a digital representation of each one of the charge pulses. A video system then displays an image associated with the digital representation of the output charge pulses clocked from the FPA. In one embodiment, the FPA image is formatted to a standard video format for display on conventional video equipment. 12 figs.

  1. STAR Images: Image gallery from the Solenoidal Tracker at RHIC

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    The primary physics task of STAR is to study the formation and characteristics of the quark-gluon plasma (QGP), a state of matter believed to exist at sufficiently high energy densities. STAR consists of several types of detectors, each specializing in detecting certain types of particles or characterizing their motion. These detectors allow final statements to be made about the collision. The gallery of STAR images makes available a small collection of event-generated images from Gold-Beam experiments, a simulation of TCP Drift, and a library of STAR instrument and construction photos.

  2. Dynamic granularity of imaging systems

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Geissel, Matthias; Smith, Ian C.; Shores, Jonathon E.; Porter, John L.

    2015-11-04

    Imaging systems that include a specific source, imaging concept, geometry, and detector have unique properties such as signal-to-noise ratio, dynamic range, spatial resolution, distortions, and contrast. Some of these properties are inherently connected, particularly dynamic range and spatial resolution. It must be emphasized that spatial resolution is not a single number but must be seen in the context of dynamic range and consequently is better described by a function or distribution. We introduce the “dynamic granularity” Gdyn as a standardized, objective relation between a detector’s spatial resolution (granularity) and dynamic range for complex imaging systems in a given environment rathermore » than the widely found characterization of detectors such as cameras or films by themselves. We found that this relation can partly be explained through consideration of the signal’s photon statistics, background noise, and detector sensitivity, but a comprehensive description including some unpredictable data such as dust, damages, or an unknown spectral distribution will ultimately have to be based on measurements. Measured dynamic granularities can be objectively used to assess the limits of an imaging system’s performance including all contributing noise sources and to qualify the influence of alternative components within an imaging system. Our article explains the construction criteria to formulate a dynamic granularity and compares measured dynamic granularities for different detectors used in the X-ray backlighting scheme employed at Sandia’s Z-Backlighter facility.« less

  3. Dynamic granularity of imaging systems

    SciTech Connect (OSTI)

    Geissel, Matthias; Smith, Ian C.; Shores, Jonathon E.; Porter, John L.

    2015-11-04

    Imaging systems that include a specific source, imaging concept, geometry, and detector have unique properties such as signal-to-noise ratio, dynamic range, spatial resolution, distortions, and contrast. Some of these properties are inherently connected, particularly dynamic range and spatial resolution. It must be emphasized that spatial resolution is not a single number but must be seen in the context of dynamic range and consequently is better described by a function or distribution. We introduce the dynamic granularity Gdyn as a standardized, objective relation between a detectors spatial resolution (granularity) and dynamic range for complex imaging systems in a given environment rather than the widely found characterization of detectors such as cameras or films by themselves. We found that this relation can partly be explained through consideration of the signals photon statistics, background noise, and detector sensitivity, but a comprehensive description including some unpredictable data such as dust, damages, or an unknown spectral distribution will ultimately have to be based on measurements. Measured dynamic granularities can be objectively used to assess the limits of an imaging systems performance including all contributing noise sources and to qualify the influence of alternative components within an imaging system. Our article explains the construction criteria to formulate a dynamic granularity and compares measured dynamic granularities for different detectors used in the X-ray backlighting scheme employed at Sandias Z-Backlighter facility.

  4. ACTIVE REGION MOSS: DOPPLER SHIFTS FROM HINODE/EXTREME-ULTRAVIOLET IMAGING SPECTROMETER OBSERVATIONS

    SciTech Connect (OSTI)

    Tripathi, Durgesh [Inter-University Centre for Astronomy and Astrophysics, Pune University Campus, Pune 411007 (India); Mason, Helen E. [Department of Applied Mathematics and Theoretical Physics, University of Cambridge, Wilberforce Road, Cambridge CB3 0WA (United Kingdom); Klimchuk, James A. [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States)

    2012-07-01

    Studying the Doppler shifts and the temperature dependence of Doppler shifts in moss regions can help us understand the heating processes in the core of the active regions. In this paper, we have used an active region observation recorded by the Extreme-ultraviolet Imaging Spectrometer (EIS) on board Hinode on 2007 December 12 to measure the Doppler shifts in the moss regions. We have distinguished the moss regions from the rest of the active region by defining a low-density cutoff as derived by Tripathi et al. in 2010. We have carried out a very careful analysis of the EIS wavelength calibration based on the method described by Young et al. in 2012. For spectral lines having maximum sensitivity between log T = 5.85 and log T = 6.25 K, we find that the velocity distribution peaks at around 0 km s{sup -1} with an estimated error of 4-5 km s{sup -1}. The width of the distribution decreases with temperature. The mean of the distribution shows a blueshift which increases with increasing temperature and the distribution also shows asymmetries toward blueshift. Comparing these results with observables predicted from different coronal heating models, we find that these results are consistent with both steady and impulsive heating scenarios. However, the fact that there are a significant number of pixels showing velocity amplitudes that exceed the uncertainty of 5 km s{sup -1} is suggestive of impulsive heating. Clearly, further observational constraints are needed to distinguish between these two heating scenarios.

  5. Intergalactic medium emission observations with the cosmic web imager. I. The circum-QSO medium of QSO 1549+19, and evidence for a filamentary gas inflow

    SciTech Connect (OSTI)

    Martin, D. Christopher; Chang, Daphne; Matuszewski, Matt; Morrissey, Patrick; Rahman, Shahin; Moore, Anna; Steidel, Charles C.

    2014-05-10

    The Palomar Cosmic Web Imager (PCWI), an integral field spectrograph designed to detect and map low surface brightness emission, has obtained imaging spectroscopic maps of Ly? from the circum-QSO medium (CQM) of QSO HS1549+19 at redshift z = 2.843. Extensive extended emission is detected from the CQM, consistent with fluorescent and pumped Ly? produced by the ionizing and Ly? continuum of the QSO. Many features present in PCWI spectral images match those detected in narrow-band images. Filamentary structures with narrow line profiles are detected in several cases as long as 250-400 kpc. One of these is centered at a velocity redshifted with respect to the systemic velocity, and displays a spatially collimated and kinematically cold line profile increasing in velocity width approaching the QSO. This suggests that the filament gas is infalling onto the QSO, perhaps in a cold accretion flow. Because of the strong ionizing flux, the neutral column density is low, typically N(H I)?10{sup 12}--10{sup 15} cm{sup ?2}, and the line center optical depth is also low (typically ?{sub 0} < 10), insufficient to display well separated double peak emission characteristic of higher line optical depths. With a simple ionization and cloud model we can very roughly estimate the total gas mass (log M {sub gas} = 12.5 0.5) and the total (log M {sub tot} = 13.3 0.5). We can also calculate a kinematic mass from the total line profile (2 10{sup 13} M {sub ?}), which agrees with the mass estimated from the gas emission. The intensity-binned spectrum of the CQM shows a progression in kinematic properties consistent with heirarchical structure formation.

  6. Extreme luminosity imaging conical spectrograph

    SciTech Connect (OSTI)

    Pikuz, S. A.; Shelkovenko, T. A.; Mitchell, M. D.; Chandler, K. M.; Douglass, J. D.; McBride, R. D.; Jackson, D. P.; Hammer, D. A.

    2006-10-15

    A new configuration for a two-dimensional (2D) imaging x-ray spectrograph based on a conically bent crystal is introduced: extreme luminosity imaging conical spectrograph (ELICS). The ELICS configuration has important advantages over spectrographs that are based on cylindrically and spherically bent crystals. The main advantages are that a wide variety of large-aperture crystals can be used, and any desired magnification in the spatial direction (the direction orthogonal to spectral dispersion) can be achieved by the use of different experimental arrangements. The ELICS can be set up so that the detector plane is almost perpendicular to the incident rays, a good configuration for time-resolved spectroscopy. ELICSs with mica crystals of 45x90 mm{sup 2} aperture have been successfully used for imaging on the XP and COBRA pulsed power generators, yielding spectra with spatial resolution in 2D of Z pinches and X pinches.

  7. Miniature hybrid optical imaging lens

    DOE Patents [OSTI]

    Sitter, Jr., David N. (Knoxville, TN); Simpson, Marc L. (Knoxville, TN)

    1997-01-01

    A miniature lens system that corrects for imaging and chromatic aberrations, the lens system being fabricated from primarily commercially-available components. A first element at the input to a lens housing is an aperture stop. A second optical element is a refractive element with a diffractive element closely coupled to, or formed a part of, the rear surface of the refractive element. Spaced closely to the diffractive element is a baffle to limit the area of the image, and this is closely followed by a second refractive lens element to provide the final correction. The image, corrected for aberrations exits the last lens element to impinge upon a detector plane were is positioned any desired detector array. The diffractive element is fabricated according to an equation that includes, as variables, the design wavelength, the index of refraction and the radius from an optical axis of the lens system components.

  8. Miniature hybrid optical imaging lens

    DOE Patents [OSTI]

    Sitter, D.N. Jr.; Simpson, M.L.

    1997-10-21

    A miniature lens system that corrects for imaging and chromatic aberrations is disclosed, the lens system being fabricated from primarily commercially-available components. A first element at the input to a lens housing is an aperture stop. A second optical element is a refractive element with a diffractive element closely coupled to, or formed a part of, the rear surface of the refractive element. Spaced closely to the diffractive element is a baffle to limit the area of the image, and this is closely followed by a second refractive lens element to provide the final correction. The image, corrected for aberrations exits the last lens element to impinge upon a detector plane were is positioned any desired detector array. The diffractive element is fabricated according to an equation that includes, as variables, the design wavelength, the index of refraction and the radius from an optical axis of the lens system components. 2 figs.

  9. Method for removing RFI from SAR images

    DOE Patents [OSTI]

    Doerry, Armin W.

    2003-08-19

    A method of removing RFI from a SAR by comparing two SAR images on a pixel by pixel basis and selecting the pixel with the lower magnitude to form a composite image. One SAR image is the conventional image produced by the SAR. The other image is created from phase-history data which has been filtered to have the frequency bands containing the RFI removed.

  10. Acoustic Imaging Suite - Energy Innovation Portal

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Acoustic Imaging Suite Idaho National Laboratory Contact INL About This Technology Technology Marketing Summary INL's acoustic imaging technology improves methods of capturing moving images of a specified object by using a photorefractive effect to produce a full-field image of the object without using a probe to perform a full scan of the object. INL technology includes a second device that produces an acoustic image of an object using acoustic wave results in the formation of at least one

  11. Interpretation of HRTEM images by image simulation: An introduction to theory and practice

    SciTech Connect (OSTI)

    O`Keefe, M.A.

    1994-08-01

    This tutorial describes the use of image simulation as an aid to interpretation of high-resolution transmission electron microscope images. Topics include some image processing as well as image simulation. Image processing is the manipulation of experimental images in order to extract some desired information. Image simulation is the generation of a computed or simulated image from a model structure. It requires a detailed knowledge of the process of image formation in the high-resolution transmission electron microscope. This tutorial concentrates on image simulation, with examples of image processing appearing only as required as illustrations. Because this is an introduction, the theory of image simulation is described, but not explored in depth. The practice of image simulation is covered in sufficient detail to enable the student to understand the functions of the various steps in the computations, and the parameters necessary for their evaluation.

  12. NEUTRON IMAGING, RADIOGRAPHY AND TOMOGRAPHY.

    SciTech Connect (OSTI)

    SMITH,G.C.

    2002-03-01

    Neutrons are an invaluable probe in a wide range of scientific, medical and commercial endeavors. Many of these applications require the recording of an image of the neutron signal, either in one-dimension or in two-dimensions. We summarize the reactions of neutrons with the most important elements that are used for their detection. A description is then given of the major techniques used in neutron imaging, with emphasis on the detection media and position readout principle. Important characteristics such as position resolution, linearity, counting rate capability and sensitivity to gamma-background are discussed. Finally, the application of a subset of these instruments in radiology and tomography is described.

  13. Seismic Imaging Processing and Migration

    Energy Science and Technology Software Center (OSTI)

    2000-06-26

    Salvo is a 3D, finite difference, prestack, depth migration code for parallel computers. It is also capable of processing 2D and poststack data. The code requires as input a seismic dataset, a velocity model and a file of parameters that allows the user to select various options. The code uses this information to produce a seismic image. Some of the options available to the user include the application of various filters and imaging conditions. Themore » code also incorporates phase encoding (patent applied for) to process multiple shots simultaneously.« less

  14. Electronic imaging system and technique

    DOE Patents [OSTI]

    Bolstad, J.O.

    1984-06-12

    A method and system for viewing objects obscurred by intense plasmas or flames (such as a welding arc) includes a pulsed light source to illuminate the object, the peak brightness of the light reflected from the object being greater than the brightness of the intense plasma or flame; an electronic image sensor for detecting a pulsed image of the illuminated object, the sensor being operated as a high-speed shutter; and electronic means for synchronizing the shutter operation with the pulsed light source.

  15. Gamma-ray Imaging Methods

    SciTech Connect (OSTI)

    Vetter, K; Mihailescu, L; Nelson, K; Valentine, J; Wright, D

    2006-10-05

    In this document we discuss specific implementations for gamma-ray imaging instruments including the principle of operation and describe systems which have been built and demonstrated as well as systems currently under development. There are several fundamentally different technologies each with specific operational requirements and performance trade offs. We provide an overview of the different gamma-ray imaging techniques and briefly discuss challenges and limitations associated with each modality (in the appendix we give detailed descriptions of specific implementations for many of these technologies). In Section 3 we summarize the performance and operational aspects in tabular form as an aid for comparing technologies and mapping technologies to potential applications.

  16. Multispectral imaging method and apparatus

    DOE Patents [OSTI]

    Sandison, D.R.; Platzbecker, M.R.; Vargo, T.D.; Lockhart, R.R.; Descour, M.R.; Richards-Kortum, R.

    1999-07-06

    A multispectral imaging method and apparatus are described which are adapted for use in determining material properties, especially properties characteristic of abnormal non-dermal cells. A target is illuminated with a narrow band light beam. The target expresses light in response to the excitation. The expressed light is collected and the target's response at specific response wavelengths to specific excitation wavelengths is measured. From the measured multispectral response the target's properties can be determined. A sealed, remote probe and robust components can be used for cervical imaging. 5 figs.

  17. Multispectral imaging method and apparatus

    DOE Patents [OSTI]

    Sandison, David R.; Platzbecker, Mark R.; Vargo, Timothy D.; Lockhart, Randal R.; Descour, Michael R.; Richards-Kortum, Rebecca

    1999-01-01

    A multispectral imaging method and apparatus adapted for use in determining material properties, especially properties characteristic of abnormal non-dermal cells. A target is illuminated with a narrow band light beam. The target expresses light in response to the excitation. The expressed light is collected and the target's response at specific response wavelengths to specific excitation wavelengths is measured. From the measured multispectral response the target's properties can be determined. A sealed, remote probe and robust components can be used for cervical imaging

  18. Electronic imaging system and technique

    DOE Patents [OSTI]

    Bolstad, Jon O.

    1987-01-01

    A method and system for viewing objects obscurred by intense plasmas or flames (such as a welding arc) includes a pulsed light source to illuminate the object, the peak brightness of the light reflected from the object being greater than the brightness of the intense plasma or flame; an electronic image sensor for detecting a pulsed image of the illuminated object, the sensor being operated as a high-speed shutter; and electronic means for synchronizing the shutter operation with the pulsed light source.

  19. Upright cone beam CT imaging using the onboard imager

    SciTech Connect (OSTI)

    Fave, Xenia Martin, Rachael; Yang, Jinzhong; Balter, Peter; Court, Laurence; Carvalho, Luis; Pan, Tinsu

    2014-06-15

    Purpose: Many patients could benefit from being treated in an upright position. The objectives of this study were to determine whether cone beam computed tomography (CBCT) could be used to acquire upright images for treatment planning and to demonstrate whether reconstruction of upright images maintained accurate geometry and Hounsfield units (HUs). Methods: A TrueBeam linac was programmed in developer mode to take upright CBCT images. The gantry head was positioned at 0°, and the couch was rotated to 270°. The x-ray source and detector arms were extended to their lateral positions. The x-ray source and gantry remained stationary as fluoroscopic projections were taken and the couch was rotated from 270° to 90°. The x-ray tube current was normalized to deposit the same dose (measured using a calibrated Farmer ion chamber) as that received during a clinical helical CT scan to the center of a cylindrical, polyethylene phantom. To extend the field of view, two couch rotation scans were taken with the detector offset 15 cm superiorly and then 15 cm inferiorly. The images from these two scans were stitched together before reconstruction. Upright reconstructions were compared to reconstructions from simulation CT scans of the same phantoms. Two methods were investigated for correcting the HUs, including direct calibration and mapping the values from a simulation CT. Results: Overall geometry, spatial linearity, and high contrast resolution were maintained in upright reconstructions. Some artifacts were created and HU accuracy was compromised; however, these limitations could be removed by mapping the HUs from a simulation CT to the upright reconstruction for treatment planning. Conclusions: The feasibility of using the TrueBeam linac to take upright CBCT images was demonstrated. This technique is straightforward to implement and could be of enormous benefit to patients with thoracic tumors or those who find a supine position difficult to endure.

  20. A COMBINED VERY LARGE TELESCOPE AND GEMINI STUDY OF THE ATMOSPHERE OF THE DIRECTLY IMAGED PLANET, ? PICTORIS b

    SciTech Connect (OSTI)

    Currie, Thayne; Jayawardhana, Ray; Burrows, Adam; Madhusudhan, Nikku; Fukagawa, Misato; Girard, Julien H.; Dawson, Rebekah; Murray-Clay, Ruth; Kenyon, Scott; Kuchner, Marc; Matsumura, Soko; Chambers, John; Bromley, Ben

    2013-10-10

    We analyze new/archival VLT/NaCo and Gemini/NICI high-contrast imaging of the young, self-luminous planet ? Pictoris b in seven near-to-mid IR photometric filters, using advanced image processing methods to achieve high signal-to-noise, high precision measurements. While ? Pic b's near-IR colors mimic those of a standard, cloudy early-to-mid L dwarf, it is overluminous in the mid-infrared compared to the field L/T dwarf sequence. Few substellar/planet-mass objectsi.e., ? And b and 1RXJ 1609Bmatch ? Pic b's JHK{sub s}L' photometry and its 3.1 ?m and 5 ?m photometry are particularly difficult to reproduce. Atmosphere models adopting cloud prescriptions and large (?60 ?m) dust grains fail to reproduce the ? Pic b spectrum. However, models incorporating thick clouds similar to those found for HR 8799 bcde, but also with small (a few microns) modal particle sizes, yield fits consistent with the data within the uncertainties. Assuming solar abundance models, thick clouds, and small dust particles ((a) = 4 ?m), we derive atmosphere parameters of log (g) = 3.8 0.2 and T{sub eff} = 1575-1650 K, an inferred mass of 7{sup +4}{sub -3} M{sub J} , and a luminosity of log(L/L{sub ?}) ?3.80 0.02. The best-estimated planet radius, ?1.65 0.06 R{sub J} , is near the upper end of allowable planet radii for hot-start models given the host star's age and likely reflects challenges constructing accurate atmospheric models. Alternatively, these radii are comfortably consistent with hot-start model predictions if ? Pic b is younger than ?7 Myr, consistent with a late formation well after its host star's birth ?12{sup +8}{sub -4} Myr ago.

  1. Covered Product Category: Imaging Equipment

    Broader source: Energy.gov [DOE]

    The Federal Energy Management Program (FEMP) provides acquisition guidance for imaging equipment, a product category covered by the ENERGY STAR program. Federal laws and requirements mandate that agencies buy ENERGY STAR qualified products in all product categories covered by this program and any acquisition actions that are not specifically exempted by law.

  2. Signal and Image Processing Operations

    Energy Science and Technology Software Center (OSTI)

    1995-05-10

    VIEW is a software system for processing arbitrary multidimensional signals. It provides facilities for numerical operations, signal displays, and signal databasing. The major emphasis of the system is on the processing of time-sequences and multidimensional images. The system is designed to be both portable and extensible. It runs currently on UNIX systems, primarily SUN workstations.

  3. Hadamard multimode optical imaging transceiver

    DOE Patents [OSTI]

    Cooke, Bradly J; Guenther, David C; Tiee, Joe J; Kellum, Mervyn J; Olivas, Nicholas L; Weisse-Bernstein, Nina R; Judd, Stephen L; Braun, Thomas R

    2012-10-30

    Disclosed is a method and system for simultaneously acquiring and producing results for multiple image modes using a common sensor without optical filtering, scanning, or other moving parts. The system and method utilize the Walsh-Hadamard correlation detection process (e.g., functions/matrix) to provide an all-binary structure that permits seamless bridging between analog and digital domains. An embodiment may capture an incoming optical signal at an optical aperture, convert the optical signal to an electrical signal, pass the electrical signal through a Low-Noise Amplifier (LNA) to create an LNA signal, pass the LNA signal through one or more correlators where each correlator has a corresponding Walsh-Hadamard (WH) binary basis function, calculate a correlation output coefficient for each correlator as a function of the corresponding WH binary basis function in accordance with Walsh-Hadamard mathematical principles, digitize each of the correlation output coefficient by passing each correlation output coefficient through an Analog-to-Digital Converter (ADC), and performing image mode processing on the digitized correlation output coefficients as desired to produce one or more image modes. Some, but not all, potential image modes include: multi-channel access, temporal, range, three-dimensional, and synthetic aperture.

  4. Low field magnetic resonance imaging

    DOE Patents [OSTI]

    Pines, Alexander; Sakellariou, Dimitrios; Meriles, Carlos A.; Trabesinger, Andreas H.

    2010-07-13

    A method and system of magnetic resonance imaging does not need a large homogenous field to truncate a gradient field. Spatial information is encoded into the spin magnetization by allowing the magnetization to evolve in a non-truncated gradient field and inducing a set of 180 degree rotations prior to signal acquisition.

  5. imaging | National Nuclear Security Administration

    National Nuclear Security Administration (NNSA)

    imaging NNSA's work aids in fight against cancer World Cancer Day encourages citizens worldwide to take action, raise awareness, and garner support in the campaign to end cancer. Inherent in NNSA's missions are technological developments for detection, computation, and chemistry-with benefits for cancer research. Scientists at NNSA's laboratories

  6. Buried object detection in GPR images

    DOE Patents [OSTI]

    Paglieroni, David W; Chambers, David H; Bond, Steven W; Beer, W. Reginald

    2014-04-29

    A method and system for detecting the presence of subsurface objects within a medium is provided. In some embodiments, the imaging and detection system operates in a multistatic mode to collect radar return signals generated by an array of transceiver antenna pairs that is positioned across the surface and that travels down the surface. The imaging and detection system pre-processes the return signal to suppress certain undesirable effects. The imaging and detection system then generates synthetic aperture radar images from real aperture radar images generated from the pre-processed return signal. The imaging and detection system then post-processes the synthetic aperture radar images to improve detection of subsurface objects. The imaging and detection system identifies peaks in the energy levels of the post-processed image frame, which indicates the presence of a subsurface object.

  7. Multi-channel medical imaging system

    DOE Patents [OSTI]

    Frangioni, John V

    2013-12-31

    A medical imaging system provides simultaneous rendering of visible light and fluorescent images. The system may employ dyes in a small-molecule form that remain in the subject's blood stream for several minutes, allowing real-time imaging of the subject's circulatory system superimposed upon a conventional, visible light image of the subject. The system may provide an excitation light source to excite the fluorescent substance and a visible light source for general illumination within the same optical guide used to capture images. The system may be configured for use in open surgical procedures by providing an operating area that is closed to ambient light. The systems described herein provide two or more diagnostic imaging channels for capture of multiple, concurrent diagnostic images and may be used where a visible light image may be usefully supplemented by two or more images that are independently marked for functional interest.

  8. Multi-channel medical imaging system

    DOE Patents [OSTI]

    Frangioni, John V.

    2016-05-03

    A medical imaging system provides simultaneous rendering of visible light and fluorescent images. The system may employ dyes in a small-molecule form that remain in a subject's blood stream for several minutes, allowing real-time imaging of the subject's circulatory system superimposed upon a conventional, visible light image of the subject. The system may provide an excitation light source to excite the fluorescent substance and a visible light source for general illumination within the same optical guide used to capture images. The system may be configured for use in open surgical procedures by providing an operating area that is closed to ambient light. The systems described herein provide two or more diagnostic imaging channels for capture of multiple, concurrent diagnostic images and may be used where a visible light image may be usefully supplemented by two or more images that are independently marked for functional interest.

  9. Fidelity imaging for atomic force microscopy

    SciTech Connect (OSTI)

    Ghosal, Sayan Salapaka, Murti

    2015-01-05

    Atomic force microscopy is widely employed for imaging material at the nanoscale. However, real-time measures on image reliability are lacking in contemporary atomic force microscopy literature. In this article, we present a real-time technique that provides an image of fidelity for a high bandwidth dynamic mode imaging scheme. The fidelity images define channels that allow the user to have additional authority over the choice of decision threshold that facilitates where the emphasis is desired, on discovering most true features on the sample with the possible detection of high number of false features, or emphasizing minimizing instances of false detections. Simulation and experimental results demonstrate the effectiveness of fidelity imaging.

  10. Image change detection systems, methods, and articles of manufacture

    DOE Patents [OSTI]

    Jones, James L.; Lassahn, Gordon D.; Lancaster, Gregory D.

    2010-01-05

    Aspects of the invention relate to image change detection systems, methods, and articles of manufacture. According to one aspect, a method of identifying differences between a plurality of images is described. The method includes loading a source image and a target image into memory of a computer, constructing source and target edge images from the source and target images to enable processing of multiband images, displaying the source and target images on a display device of the computer, aligning the source and target edge images, switching displaying of the source image and the target image on the display device, to enable identification of differences between the source image and the target image.

  11. SU-E-I-45: Reconstruction of CT Images From Sparsely-Sampled Data Using the Logarithmic Barrier Method

    SciTech Connect (OSTI)

    Xu, H

    2014-06-01

    Purpose: To develop and investigate whether the logarithmic barrier (LB) method can result in high-quality reconstructed CT images using sparsely-sampled noisy projection data Methods: The objective function is typically formulated as the sum of the total variation (TV) and a data fidelity (DF) term with a parameter ? that governs the relative weight between them. Finding the optimized value of ? is a critical step for this approach to give satisfactory results. The proposed LB method avoid using ? by constructing the objective function as the sum of the TV and a log function whose augment is the DF term. Newton's method was used to solve the optimization problem. The algorithm was coded in MatLab2013b. Both Shepp-Logan phantom and a patient lung CT image were used for demonstration of the algorithm. Measured data were simulated by calculating the projection data using radon transform. A Poisson noise model was used to account for the simulated detector noise. The iteration stopped when the difference of the current TV and the previous one was less than 1%. Results: Shepp-Logan phantom reconstruction study shows that filtered back-projection (FBP) gives high streak artifacts for 30 and 40 projections. Although visually the streak artifacts are less pronounced for 64 and 90 projections in FBP, the 1D pixel profiles indicate that FBP gives noisier reconstructed pixel values than LB does. A lung image reconstruction is presented. It shows that use of 64 projections gives satisfactory reconstructed image quality with regard to noise suppression and sharp edge preservation. Conclusion: This study demonstrates that the logarithmic barrier method can be used to reconstruct CT images from sparsely-amped data. The number of projections around 64 gives a balance between the over-smoothing of the sharp demarcation and noise suppression. Future study may extend to CBCT reconstruction and improvement on computation speed.

  12. Fiji Is Just ImageJ

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    be described as a "batteries-included" distribution of ImageJ (and ImageJ2), bundling Java, Java3D and a lot of plugins organized into a coherent structure. Availability Fiji's...

  13. Lensless X-Ray Imaging in Reflection

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    X-Ray Imaging in Reflection Print The advent of x-ray free-electron laser (XFEL) light sources has led to an outburst of research activities in the field of lensless imaging. XFELs...

  14. Lensless X-Ray Imaging in Reflection

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Lensless X-Ray Imaging in Reflection Lensless X-Ray Imaging in Reflection Print Wednesday, 26 October 2011 00:00 The advent of x-ray free-electron laser (XFEL) light sources has...

  15. ARM - Evaluation Product - Multispectral Thermal Imager (MTI...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    to hear from you Send us a note below or call us at 1-888-ARM-DATA. Send Evaluation Product : Multispectral Thermal Imager (MTI) The Multispectral Thermal Imager is a...

  16. Vectorized image segmentation via trixel agglomeration

    DOE Patents [OSTI]

    Prasad, Lakshman; Skourikhine, Alexei N.

    2006-10-24

    A computer implemented method transforms an image comprised of pixels into a vectorized image specified by a plurality of polygons that can be subsequently used to aid in image processing and understanding. The pixelated image is processed to extract edge pixels that separate different colors and a constrained Delaunay triangulation of the edge pixels forms a plurality of triangles having edges that cover the pixelated image. A color for each one of the plurality of triangles is determined from the color pixels within each triangle. A filter is formed with a set of grouping rules related to features of the pixelated image and applied to the plurality of triangle edges to merge adjacent triangles consistent with the filter into polygons having a plurality of vertices. The pixelated image may be then reformed into an array of the polygons, that can be represented collectively and efficiently by standard vector image.

  17. Arctic Clouds Infrared Imaging Field Campaign Report

    Office of Scientific and Technical Information (OSTI)

    ... The right-hand photo shows the IR camera looking up (upper right), large-area blackbody ... Raw digital images from the thermal camera were calibrated to produce radiance images W...

  18. Single System Image Cluster Management

    Energy Science and Technology Software Center (OSTI)

    2004-02-13

    Cluster computing has quickly proven itself to be a capable workhorse for a wide variety of production computing tasks; however, setting up and maintaining a cluster still requires significantly more effort than administrating just a single machine. As computing hardware descreases in price and cluster sizes grow, it is becoming increasingly important to manage clusters cleverly so that a system administration effort can "scale" as well. To ease the task of mananging many machines, administratorsmore » often deploy an environment that is homogeneous across all nodes of a cluster, and maintain a snapshot of the filesystem as a 'master image'. However due to operational, behavioral, and physical constraints, many nodes often require numerous deviations from the master image in order to operate as desired.« less

  19. Nondestructive Imaging of Individual Biomolecules

    SciTech Connect (OSTI)

    Germann, Matthias; Latychevskaia, Tatiana; Escher, Conrad; Fink, Hans-Werner

    2010-03-05

    Radiation damage is considered to be the major problem that still prevents imaging an individual biological molecule for structural analysis. So far, all known mapping techniques using sufficient short wavelength radiation, be it x rays or high energy electrons, circumvent this problem by averaging over many molecules. Averaging, however, leaves conformational details uncovered. Even the anticipated use of ultrashort but extremely bright x-ray bursts of a free electron laser shall afford averaging over 10{sup 6} molecules to arrive at atomic resolution. Here, we present direct experimental evidence for nondestructive imaging of individual DNA molecules. In fact, we show that DNA withstands coherent low energy electron radiation with deBroglie wavelength in the Angstrom regime despite a vast dose of 10{sup 8} electrons/nm{sup 2} accumulated over more than one hour.

  20. Dynamic imaging with electron microscopy

    ScienceCinema (OSTI)

    Campbell, Geoffrey; McKeown, Joe; Santala, Melissa

    2014-05-30

    Livermore researchers have perfected an electron microscope to study fast-evolving material processes and chemical reactions. By applying engineering, microscopy, and laser expertise to the decades-old technology of electron microscopy, the dynamic transmission electron microscope (DTEM) team has developed a technique that can capture images of phenomena that are both very small and very fast. DTEM uses a precisely timed laser pulse to achieve a short but intense electron beam for imaging. When synchronized with a dynamic event in the microscope's field of view, DTEM allows scientists to record and measure material changes in action. A new movie-mode capability, which earned a 2013 R&D 100 Award from R&D Magazine, uses up to nine laser pulses to sequentially capture fast, irreversible, even one-of-a-kind material changes at the nanometer scale. DTEM projects are advancing basic and applied materials research, including such areas as nanostructure growth, phase transformations, and chemical reactions.

  1. Image

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    SOLICWfATION/MODIFICATlON OF CONTRACT 2< AMENDMt;NT/MODIFfCAnON NO, 3.'EFFEC1fVE DArE 202 See Block 16C 6. ISSUED BY CODE 00518 Oak Ridge U.S. Department of Energy P.O. Box 2001 Oak Ridge 'l'N 37831 8. N~MEAND ADDRE~ OF CONTRACTOR INc..,~, emmly, SUlf9andljpCode} AK RIDGE Q P Q .0. BOX AKRIDGE ASSOCIATED UNIVERSITIES, INC. 117 TN 37830-6218 1" CONlRACTIP WDE I PAG!±: OF PAGES 1 I 1 4. Re:aUiS!ilON:!PURCHASE REQ. NQ. IS. PROJECT NO. (lfspp/kJabfe) 10SCQ0874 7 Itt0tl'\ 5 7. ADMINlSTEf{EO

  2. Image

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    CONTRACT!D CODE IPAU!£ 0, PAGeS 1 10 Z, AMENOMENT/MOO[PICATIQN NO, 3, EFI'tECT!Va DATE 4. REQU!SmoNtPuRCHASE'REQ. NO. 15, PROJECT NO. ("appllen!)I,,) 178. See BIQC¥ 16C 1080008480 6: I$SueD- BY COOE 00518 7. ADMINJSTERED ay lffothOrffum Item 6) CODE 100518 Oak Rl.<lge Oak Ridge U.S. Department of Enet"gy t!. S. D-Opartmen t of Energy P.O. Box 2001 J? .0. Box 2001 .oak Ridge l'N 37831 Oak R'idge TN 37831 tl-. NAMEAND ADDRESS- OF CONrRACTOR (/'to" srrfMJj. <:.euflfy, Sialf!

  3. Image

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AM!;NDMENT OFSOI.ICFl'ATlONlMPDIFICATION OF CONTRACT 2. AMt;N.DMENT/MOD!FICATION' NO, S', EFFECTIVE DAlE 179 See Bl'ock 16C 6.ISSUEUBY COPE 00518 Oak Ridge U~S. Departmerit of Erergy P,Q. Box. 2001 Oak Ridge TN 37831 8. NAME ANDADOR6S$ OF CONTRACTOR (No" Wrw/. ;JOWl/y. stllffl IiWJ ZIP Code) AK RIDGE ASSOCIA'rED UNIVERSITIES, o p .0. BOX 117 o 11K RIDGE TN 37830-6.218 INC. j 1. CONTRACT 10 CqDE I PAGE Of PAGES 11 5 ' 4, HEQUlSrTlONIPURCHASE ,REO:. NO. r PROJECT NO, flf applfcabla)

  4. Image

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

  5. Image

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

  6. Image

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

  7. Image

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

  8. Image

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

  9. Image

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

  10. Image

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

  11. Image

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

  12. Image

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    MA RTINEZ Governor JOHN A. SANCHEZ Lieutenant Governor NEW MEXICO ENVIRONMENT DEPARTMENT Hazardous Waste Bureau 2905 Rodeo Park Drive East, Building 1 Santa Fe, New Mexico 87505-6303 Phone (505) 476-6000 Fax (505) 476-6030 www.llmellv.Sfale.IlIll.1I s CERTIFIED MAIL - RETURN REC EIPT REQUESTED DAVE MARTIN Secretary BUTCH TONOATE Deputy Secretary May 30, 2012 RECEIVED JUN 1 lOll General M QU. anager's '1tce Jose R. Franco, Manager Carlsbad Field Office Department of Energy P.O. Box 3090 Carl

  13. Image

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    JOH N A. SANCHEZ Lieutenant Governor NEW MEXICO ENVIRONMENT DEPARTMENT Hazardous Waste Bureau 2905 Rodeo Park Drive East, Building 1 Santa Fe, New Mexico 87505*6303 Phone (505) 476*6000 Fax (505) 476*6030 WWW. lUneIl V.state.llnt.us CERTIFI ED MAIL* RETURN RECEIPT R EQUESTED August 24, 20 12 Jose R. Franco, M anager Carl sbad Field Office Departmen t of Energy P.O. Box 3090 Carl sbad, New M ex ico 8822 1 *3090 M. Farok Sharif Washington TRU Solutions LLC P.O. Box 2078 Carlsbad, New Mexico 88221

  14. Image

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    WWW.llmenv.slate.nm.us DAVE MARTIN Secretary BUTCH TONGATE Deputy Secretary CERTIFIED MAIL - RETURN RECEIPT REQUESTED February 17,2012 Jose R. Franco, Manager Carlsbad Field Office Department of Energy P. O. Box 3090 Carlsbad, New Mexico 88221-3090 M. Farok Sharif, General Manager Washington TRU Solutions LLC P. O. Box 2078 Carlsbad, New Mexico 88221-5608 RE: ADMINISTRATIVE COMPLETENESS DETERMINATION AND FEE ASSESSMENT FOR CLASS 1 PERMIT MODIFICATION DATED FEBRUARY 12,2012 TO THE HAZARDOUS WASTE

  15. Image

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    MARTINI:'!, Governor JOHN A SANCHI":Z Lieutenant Governor NEW MEXICO ENVIRONMENT DEPARTMENT Hazardous Waste Bureau 2905 Rodeo Park Drive East, Building 1 Santa Fe, New Mexico 87505-6303 Phone (505) 476-6000 Fax (505) 476-6030 www.nmenv.state.nm.us CERTIFIED MAIL - RETURN RECEIPT REQUESTED October 13,2013 Jose R. Franco, Manager Carlsbad Field Office Department of Energy P.O. Box 3090 Carlsbad, New Mexico 88221-3090 M. Farok Sharif, Project Manager Nuclear Waste Partnership LLC P.O. Box 2078

  16. Image

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    SliSANA MARTINEZ Governol' JOHN A. SANCHEZ Lieutenant Governor September 28, 2012 Jose Franco, Manager Carlsbad Field Office Department of Energy P.O. Box 3090 NEW MEXICO ENVIRONMENT DEPARTMENT Resource Protection Division Harold Runnels Building 1190 Saint Francis Drive (87505) P.O. Box 5469, Santa Fe, NM 87502-5469 Phone (505) 827-0419 Fax (505) 827-0310 W\V~V. nnl~X~Y".B!il t C .1}111.1I.::>. CERTIFIED MAIL - RETURN RECEIPT REQUESTED M. Farok Sharif Washington TRU Solutions LLC P.O.

  17. Image

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    MA!n!NEZ Governor JOHN A, SANCHEZ Lieutenant Governor July 29, 2013 Jose Franco, Manager Carlsbad Field Office Department of Energy P.O. Box 3090 NEW MEXICO ENVIRONMENT DEPARTMENT Hazardous Waste Bureau 2905 Rodeo Park Drive East, Building 1 Santa Fe, New Mexico 87505*6303 Phone (505) 476*6000 Fax (505) 476*6030 www.nmenv.state.nm.us CERTIFIED MAIL' RETURN RECEIPT REQUESTED M. Farok Sharif, Project Manager Nuclear Waste Partnership LLC P.O. Box 2078 Carlsbad, New Mexico 88221*5608 Carlsbad, New

  18. Image

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Nov, 1. 2011 1: 08PM SUSANA MARTINEZ Go\'crnor lOI'IN A. SANCHEZ Lieutenanl Go\'crnor November 2,201 I NEW MEXICO ENVIRONMENT DEPARTMENT Hazardous Waste Bureau 2905 Rodeo Pal'k DI'ive East, Building 1 Santn Fe, New Mexico 81505-6303 Phone (505) 476*6000 Fax (50S) 476.6030 IVI VIP, "n um l'.,f (flfC.1I m .1IS CERTIFIED MAIL - RETURN RECEIPT REQUESTED Fru:ok Sharif No , 0170 p , 112 DAVE MARTIN SecrelOry BUTCH TONGAn: AC lillg Deputy Sccremry General M 0'" anager', /lIce Edward

  19. Image

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    MA RTINEZ Governor JOHN A. SANCHEZ Lieutenant Governor NEW MEXICO ENVIRONMENT DEPARTMENT Hazardous Waste Bureau 2905 Rodeo Park Drive East, Building 1 Santa Fe, New Mexico...

  20. Image

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    MAnNEZ Governor JOHN A, SANCHEZ Lieutenant Governor July 29, 2013 Jose Franco, Manager Carlsbad Field Office Department of Energy P.O. Box 3090 NEW MEXICO ENVIRONMENT DEPARTMENT...

  1. Image

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    SliSANA MARTINEZ Governol' JOHN A. SANCHEZ Lieutenant Governor September 28, 2012 Jose Franco, Manager Carlsbad Field Office Department of Energy P.O. Box 3090 NEW MEXICO...

  2. Image

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Nov, 1. 2011 1: 08PM SUSANA MARTINEZ Go'crnor lOI'IN A. SANCHEZ Lieutenanl Go'crnor November 2,201 I NEW MEXICO ENVIRONMENT DEPARTMENT Hazardous Waste Bureau 2905 Rodeo Pal'k...

  3. Image

    Energy Savers [EERE]

    Snyder, Ph.D. Ohio Historic Preservation Office Archaeology Reviews Manager Resource Protection and Review 1982 Velma Avenue Columbus, Ohio 43211 Dear Dr. Snyder: Department of Energy Portsmouth/Paducah Project Office 1017 Majestic Drive, Suite 200 Lexington, Kentucky 40513 (859) 219-4000 NOV 2 2 20Ut PPPO-03-1025228-11 PHASE II SITE EVALUATIONS OF 33PK212 AND 33PK213 FOR THE PORTSMOUTH GASEOUS DIFFUSION FACILITY, SEAL TOWNSHIP, PIKE COUNTY, OHIO The purpose of this letter is to provide the

  4. Image

    Energy Savers [EERE]

  5. Image

    Energy Savers [EERE]

  6. Image

    Energy Savers [EERE]

  7. Image

    Energy Savers [EERE]

  8. Image

    Energy Savers [EERE]

  9. Image

    Energy Savers [EERE]

  10. Image

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... Application, "Permittee Level TRU Waste Confirmation ... the site to the undergrou nd hazardous waste management units. ... list of process codes be low that be st describes ea ch ...

  11. Image

    Office of Legacy Management (LM)

  12. Imaging

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    the specimen through the small illuminated spot. Lithography, a technique used in the art world for many centuries, has been adopted and adapted with phenomenal success by the...

  13. Image

    Office of Environmental Management (EM)

    Exchange Membrane Fuel Cell Markets | Department of Energy Identification and Characterization of Near-Term Direct Hydrogen Proton Exchange Membrane Fuel Cell Markets Identification and Characterization of Near-Term Direct Hydrogen Proton Exchange Membrane Fuel Cell Markets This document provides information about near-term markets (such as for forklifts and telecommunications) for proton exchange membrane fuel cells. PDF icon pemfc_econ_2006_report_final_0407.pdf More Documents &

  14. Image

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    www.nmenv.state.nm.us CERTIFIED MAIL - RETURN RECEIPT REQUESTED October 13,2013 Jose R. Franco, Manager Carlsbad Field Office Department of Energy P.O. Box 3090 Carlsbad,...

  15. Image

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    TONGATE Deputy Secretary CERTIFIED MAIL - RETURN RECEIPT REQUESTED February 17,2012 Jose R. Franco, Manager Carlsbad Field Office Department of Energy P. O. Box 3090 Carlsbad,...

  16. Image

    National Nuclear Security Administration (NNSA)

  17. SAR Image Complex Pixel Representations

    SciTech Connect (OSTI)

    Doerry, Armin W.

    2015-03-01

    Complex pixel values for Synthetic Aperture Radar (SAR) images of uniform distributed clutter can be represented as either real/imaginary (also known as I/Q) values, or as Magnitude/Phase values. Generally, these component values are integers with limited number of bits. For clutter energy well below full-scale, Magnitude/Phase offers lower quantization noise than I/Q representation. Further improvement can be had with companding of the Magnitude value.

  18. Coherent Communications, Imaging and Targeting

    SciTech Connect (OSTI)

    Stappaerts, E; Baker, K; Gavel, D; Wilks, S; Olivier, S; Brase, J; Olivier, S; Brase, J

    2003-10-03

    Laboratory and field demonstration results obtained as part of the DARPA-sponsored Coherent Communications, Imaging and Targeting (CCIT) program are reviewed. The CCIT concept uses a Phase Conjugation Engine based on a quadrature receiver array, a hologram processor and a spatial light modulator (SLM) for high-speed, digital beam control. Progress on the enabling MEMS SLM, being developed by a consortium consisting of LLNL, academic institutions and small businesses, is presented.

  19. WIPP - Passive Institutional Controls (PICs) Images

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    PICs Images Passive Institutional Controls PICs Images Permanent Markers | Images from Monument Survey Permanent Markers Earthen Berm The "big picture" Repository footprint Buried room Information center (surface center of berm) Small subsurface marker Large surface marker Marker at the Gnome Site (1/6 the size of a WIPP large surface marker) Early Concepts Back to top Images from Monument Survey Back to top

  20. Radiation Detector & Imaging | Jefferson Lab

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Radiation Detector & Imaging At Jefferson Lab, scientists, engineers and technicians in the Radiation Detector & Imaging Group adapt cutting-edge nuclear physics research detector technology to develop application-specific, radioisotope imaging systems. Technology has been developed for a variety of bio-medical applications such as medical-oriented clinical and preclinical research as well as for plant biology research. Jefferson Lab's Radiation Detector and Imaging Group Members of