National Library of Energy BETA

Sample records for ilo saxon cold

  1. International Labor Organization (ILO) | Open Energy Information

    Open Energy Info (EERE)

    Switzerland Year Founded: 1919 References: http:www.ilo.orggloballang--enindex.htma1 Overview "The ILO is the international organization responsible for drawing up and...

  2. Saxon Windpower Ltd | Open Energy Information

    Open Energy Info (EERE)

    Saxon Windpower Ltd Jump to: navigation, search Name: Saxon Windpower Ltd Place: Ipswich, United Kingdom Zip: IP19 0LA Sector: Wind energy Product: Wind farm developer....

  3. Cold War | National Nuclear Security Administration

    National Nuclear Security Administration (NNSA)

    Cold War

  4. cold standby

    Energy Savers [EERE]

    Cold Standby Program at the Portsmouth Gaseous Diffusion Plant DOE/IG-0634 December 2003 Program Results and Cost Details of Finding ...................................................................... 1 Recommendations and Comments ........................................... 5 Appendices Prior Reports .............................................................................. 7 Objective, Scope, and Methodology .......................................... 8 Management Comments

  5. COLD TRAP

    DOE Patents [OSTI]

    Milleron, N.

    1963-03-12

    An improved linear-flow cold trap is designed for highvacuum applications such as mitigating back migration of diffusion pump oil moiecules. A central pot of liquid nitrogen is nested within and supported by a surrounding, vertical, helical coil of metai sheet, all enveloped by a larger, upright, cylindrical, vacuum vessel. The vertical interstices between successive turns of the coil afford lineal, axial, high-vacuum passages between open mouths at top and bottom of said vessel, while the coil, being cold by virtue of thermal contact of its innermost turn with the nitrogen pot, affords expansive proximate condensation surfaces. (AEC)

  6. COLD TRAPS

    DOE Patents [OSTI]

    Thompson, W.I.

    1958-09-30

    A cold trap is presented for removing a condensable component from a gas mixture by cooling. It consists of a shell, the exterior surface of which is chilled by a refrigerant, and conductive fins welded inside the shell to condense the gas, and distribute the condensate evenly throughout the length of the trap, so that the trap may function until it becomes completely filled with the condensed solid. The contents may then be removed as either a gas or as a liquid by heating the trap. This device has particuinr use as a means for removing uranium hexafluoride from the gaseous diffusion separation process during equipment breakdown and repair periods.

  7. Cold fusion, Alchemist's dream

    SciTech Connect (OSTI)

    Clayton, E.D.

    1989-09-01

    In this report the following topics relating to cold fusion are discussed: muon catalysed cold fusion; piezonuclear fusion; sundry explanations pertaining to cold fusion; cosmic ray muon catalysed cold fusion; vibrational mechanisms in excited states of D{sub 2} molecules; barrier penetration probabilities within the hydrogenated metal lattice/piezonuclear fusion; branching ratios of D{sub 2} fusion at low energies; fusion of deuterons into {sup 4}He; secondary D+T fusion within the hydrogenated metal lattice; {sup 3}He to {sup 4}He ratio within the metal lattice; shock induced fusion; and anomalously high isotopic ratios of {sup 3}He/{sup 4}He.

  8. Cold fusion research

    SciTech Connect (OSTI)

    1989-11-01

    I am pleased to forward to you the Final Report of the Cold Fusion Panel. This report reviews the current status of cold fusion and includes major chapters on Calorimetry and Excess Heat, Fusion Products and Materials Characterization. In addition, the report makes a number of conclusions and recommendations, as requested by the Secretary of Energy.

  9. Hot and cold fusion

    SciTech Connect (OSTI)

    Not Available

    1990-08-01

    This article presents an overview of research in cold fusion research and development in cold fusion at the Tokomak Fusion Test Reactor at the Princeton Plasma Physics Lab, and at the inertial containment facility at Lawrence Livermore National Lab. is described.

  10. Intersecting Cold Pools: Convective Cloud Organization by Cold...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Intersecting Cold Pools: Convective Cloud Organization by Cold Pools over Tropical Ocean For original submission and image(s), see ARM Research Highlights http:www.arm.gov...

  11. Cold spray nozzle design

    DOE Patents [OSTI]

    Haynes, Jeffrey D.; Sanders, Stuart A.

    2009-06-09

    A nozzle for use in a cold spray technique is described. The nozzle has a passageway for spraying a powder material, the passageway having a converging section and a diverging section, and at least the diverging section being formed from polybenzimidazole. In one embodiment of the nozzle, the converging section is also formed from polybenzimidazole.

  12. Cold fusion coatings

    SciTech Connect (OSTI)

    Wachtler, W.R.

    1993-12-31

    Historically, fusion of metals was accomplished through the use of heat. Cold fusion has become a reality with metal to metal fusion occurring at room temperature. The basics of this new technology which can be done in tank, brush or solid form is covered in this paper.

  13. Radial cold trap

    DOE Patents [OSTI]

    Grundy, Brian R.

    1981-01-01

    The radial cold trap comprises a housing having a plurality of mesh bands disposed therein. The mesh bands comprise concentrically arranged bands of mesh with the mesh specific surface area of each band increasing from the outermost mesh band to the innermost mesh band. An inlet nozzle is attached to the outside section of the housing while an outlet nozzle is attached to the inner portion of the housing so as to be concentrically connected to the innermost mesh band. An inlet baffle having orifices therein may be disposed around the outermost mesh band and within the housing for directing the flow of the fluid from the inlet nozzle to the outermost mesh band in a uniform manner. The flow of fluid passes through each consecutive mesh band and into the outlet nozzle. The circular pattern of the symmetrically arranged mesh packing allows for better utilization of the entire cold trap volume.

  14. Radial cold trap

    DOE Patents [OSTI]

    Grundy, B.R.

    1981-09-29

    The radial cold trap comprises a housing having a plurality of mesh bands disposed therein. The mesh bands comprise concentrically arranged bands of mesh with the mesh specific surface area of each band increasing from the outermost mesh band to the innermost mesh band. An inlet nozzle is attached to the outside section of the housing while an outlet nozzle is attached to the inner portion of the housing so as to be concentrically connected to the innermost mesh band. An inlet baffle having orifices therein may be disposed around the outermost mesh band and within the housing for directing the flow of the fluid from the inlet nozzle to the outermost mesh band in a uniform manner. The flow of fluid passes through each consecutive mesh band and into the outlet nozzle. The circular pattern of the symmetrically arranged mesh packing allows for better utilization of the entire cold trap volume. 2 figs.

  15. Cold nuclear fusion

    SciTech Connect (OSTI)

    Tsyganov, E. N.

    2012-02-15

    Recent accelerator experiments on fusion of various elements have clearly demonstrated that the effective cross-sections of these reactions depend on what material the target particle is placed in. In these experiments, there was a significant increase in the probability of interaction when target nuclei are imbedded in a conducting crystal or are a part of it. These experiments open a new perspective on the problem of so-called cold nuclear fusion.

  16. Solid Cold - A

    Office of Scientific and Technical Information (OSTI)

    Celebrating Einstein "Solid Cold" By the early 20th century, the way in which temperatures of solid objects changed as they absorbed heat was considered strong evidence that matter was not made of atoms. Einstein used some recent discoveries about light to turn this assessment around. A B C D E F A. A puzzle, and a surprising solution Take equal masses of lead and aluminum. Heat them until their temperatures are both 10 degrees higher. Will it take the same amount of heat for each?

  17. Peregrinations on cold fusion

    SciTech Connect (OSTI)

    Turner, L.

    1989-01-01

    Attention is focused on the possibility of resonance-enhanced deuteron Coulomb barrier penetration. Because of the many-body nature of the interactions of room-temperature deuterons diffusing through a lattice possessing deuterons in many of the interstitial positions, the diffusing deuterons can resonate on the atomic scale in the potential wells bounded by the ascending walls of adjacent Coulomb barriers and thereby penetrate the Coulomb barriers in a fashion vastly underestimated by two-body calculations in which wells for possible resonance are absent. Indeed, perhaps the lack of robust reproducibility in cold fusion originates from the narrowness of such transmission resonances. 4 refs., 1 fig.

  18. Cold isopressing method

    SciTech Connect (OSTI)

    Chen, Jack C.; Stawisuck, Valerie M.; Prasad, Ravi

    2003-01-01

    A cold isopressing method in which two or more layers of material are formed within an isopressing mold. One of the layers consists of a tape-cast film. The layers are isopressed within the isopressing mold, thereby to laminate the layers and to compact the tape-cast film. The isopressing mold can be of cylindrical configuration with the layers being coaxial cylindrical layers. The materials used in forming the layers can contain green ceramic materials and the resultant structure can be fired and sintered as necessary and in accordance with known methods to produce a finished composite, ceramic structure. Further, such green ceramic materials can be of the type that are capable of conducting hydrogen or oxygen ions at high temperature with the object of utilizing the finished composite ceramic structure as a ceramic membrane element.

  19. Residential Cold Climate Heat Pump (CCHP)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Residential Cold Climate Heat Pump (CCHP) 2014 Building Technologies Office Peer Review ... systems. 2 The Unico Cold Climate Heat Pump (CCHP) * In partnership with the U.S. ...

  20. Plasma fusion and cold fusion

    SciTech Connect (OSTI)

    Hideo, Kozima

    1996-12-31

    Fundamental problems of plasma fusion (controlled thermonuclear fusion) due to the contradicting demands of the magnetic confinement of plasma and suppression of instabilities occurring on and in plasma are surveyed in contrast with problems of cold fusion. Problems in cold fusion due to the complicated constituents and types of force are explained. Typical cold fusion events are explained by a model based on the presence of trapped neutrons in cold fusion materials. The events include Pons-Fleishmann effect, tritium anomaly, helium 4 production, and nuclear transmutation. Fundamental hypothesis of the model is an effectiveness of a new concept--neutron affinity of elements. The neutron affinity is defined and some bases supporting it are explained. Possible justification of the concept by statistical approach is given.

  1. Guides and Case Studies for Cold and Very Cold Climates | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy Cold and Very Cold Climates Guides and Case Studies for Cold and Very Cold Climates Map of the Cold & Very Cold Zones of the United States. The far tips of North Dakota, Maine, and southern Alaska are shown as Very Cold. The northern half of the United States is shown as Cold. The U.S. Department of Energy (DOE) Building America program has developed a best practice guide and case studies to help builders improve whole-house energy performance in homes found in cold and very

  2. Cold air systems: Sleeping giant

    SciTech Connect (OSTI)

    MacCracken, C.D. )

    1994-04-01

    This article describes how cold air systems help owners increase the profits from their buildings by reducing electric costs and improving indoor air quality through lower relative humidity levels. Cold air distribution involves energy savings, cost savings, space savings, greater comfort, cleaner air, thermal storage, tighter ducting, coil redesign, lower relative humidities, retrofitting, and improved indoor air quality (IAQ). It opens a door for architects, engineers, owners, builders, environmentalists, retrofitters, designers, occupants, and manufacturers. Three things have held up cold air's usage: multiple fan-powered boxes that ate up the energy savings of primary fans. Cold air room diffusers that provided inadequate comfort. Condensation from ducts, boxes, and diffusers. Such problems have been largely eliminated through research and development by utilities and manufacturers. New cold air diffusers no longer need fan powered boxes. It has also been found that condensation is not a concern so long as the ducts are located in air conditioned space, such as drop ceilings or central risers, where relative humidity falls quickly during morning startup.

  3. Cold Test Facility - Hanford Site

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Projects & Facilities Cold Test Facility About Us About Hanford Cleanup Hanford History Hanford Site Wide Programs Contact Us 100 Area 118-K-1 Burial Ground 200 Area 222-S Laboratory 242-A Evaporator 300 Area 324 Building 325 Building 400 Area/Fast Flux Test Facility 618-10 and 618-11 Burial Grounds 700 Area B Plant B Reactor C Reactor Canister Storage Building and Interim Storage Area Canyon Facilities Cold Test Facility D and DR Reactors Effluent Treatment Facility Environmental

  4. Cold fusion; Myth versus reality

    SciTech Connect (OSTI)

    Rabinowitz, M. )

    1990-01-01

    Experiments indicate that several different nuclear reactions are taking place. Some of the experiments point to D-D fusion with a cominant tritium channel as one of the reactions. The article notes a similarity between Prometheus and the discoveries of cold fusion.

  5. Nattoh model for cold fusion

    SciTech Connect (OSTI)

    Matsumoto, T. . Dept. of Nuclear Engineering)

    1989-12-01

    A hypothetical model, the Nattoh model, is proposed to answer the questions that result from cold fusion experiments. This model proposes the formation of a small cluster of deuterons and examines the feasibility of many-body fusion reactions. The gamma-ray spectrum, heat production, neutron emissions, and fusion products are discussed.

  6. Cold fusion in condensed matter

    SciTech Connect (OSTI)

    Schommers, W.; Politis, C. )

    1989-01-01

    A model for cold fusion in condensed matter is proposed (cold fusion of deuterons in palladium). It is assumed that the palladium-deuterium system forms an alloy, i.e., it is assumed that Pd ions as well as d/sup +/ ions are embedded in an uniform background of negative charge (conduction electrons). The model is based on an interaction potential for deuterons in solid palladium which has been estimated by means of a theoretical picture well known in the physics of liquids. In particular, the following effects are possible: 1. Cold fusion in condensed matter can take place. 2. The observed energy should be larger than that given by the fusion reactions. 3. Hitherto unknown nuclear processes must not be postulated as reported by Fleischmann and Pons. 4. The deuterons are mobile. 5. The deuterons can form close-packed clusters, and in principle a fusion reaction can take place within such a cluster. 6. Not only /sup 3/He should be produced in Pd but possible /sup 4/He too. From their theoretical picture, it can be concluded that experimental results will be strongly dependent on the condition of the materials used in the experiments. This can possible explain that only a part of experiments could show up cold fusion. A well defined condition (lattice defects, different phases, impurities, etc.) of the materials is probably the most critical point in connection with the observation of cold fusion in condensed matter. The effect should also be influenced by lattice dilatations. Experiments with other materials instead of palladium (e.g. vanadium, titanium, lanthanide metals, and different alloys) should be probably more informative.

  7. PHEV Engine Cold Start Emissions Management | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Cold Start Emissions Management PHEV Engine Cold Start Emissions Management Coordination of engine and powertrain supervisory control strategies to minimize cold start emissions ...

  8. Residential Cold Climate Heat Pump (CCHP)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Craig Messmer, craig@unicosystem.com Unico, Inc. Residential Cold Climate Heat Pump (CCHP) ... systems. 3 The Unico Cold Climate Heat Pump (CCHP) * In partnership with the U.S. ...

  9. Advanced energy conversion methods for cold fusion

    SciTech Connect (OSTI)

    Prelas, M.A. )

    1989-09-01

    If cold fusion is verified, then the next important question deals with how it can be used to produce energy. Several direct energy conversion concepts for use with cold fusion are discussed.

  10. Possible natural cold fusion in the atmosphere

    SciTech Connect (OSTI)

    Hawkins, N. )

    1991-07-01

    Nongeological natural cold fusion effects in meteoroelectrical disequilibria are possible, and various laboratory simulations of these effects are being studied.

  11. Cold fusion anomalies more perplexing than ever

    SciTech Connect (OSTI)

    Dagani, R

    1989-11-01

    This article addresses the debate over research on cold fusion. Analysis is made of the research efforts that have taken place since cold fusion was first thought to have been discovered in Utah. Research in the Soviet Union on the cold fusion phenomenon is also discussed.

  12. The reality of cold fusion

    SciTech Connect (OSTI)

    Case, L.C. )

    1991-12-01

    Despite the unreproducibility, doubt, and controversy involved in the question of the cold fusion of deuterium, enough good data have been published to clearly indicate the reality of some sort of nuclear fusion. Yamaguchi and Niushioka reported a thrice-repeated event in which large amounts of heat and definite bursts of neutrons evolved simultaneously with considerable out-gassing of absorbed deuterium. These results are consistent with nuclear fusion and not with a chemical reaction. In this paper a detailed mechanism is proposed that is consistent with these events and that also generally explains many of the scattered indications of cold fusion that have been reported. There must be an adventitiously large enough presence of tritium to initiate the nuclear reaction. The results of previously successful experiments cannot now be reproduced because currently available D{sub 2}O (and D{sub 2}) is so low in adventitious tritium as to preclude initiation of the nuclear reaction.

  13. Cold cathode vacuum discharge tube

    DOE Patents [OSTI]

    Boettcher, Gordon E.

    1998-01-01

    A cold cathode vacuum discharge tube, and method for making same, with an interior surface of the trigger probe coated with carbon deposited by carbon vapor deposition (CVD) or diamond-like carbon (DLC) deposition. Preferably a solid graphite insert is employed in the probe-cathode structure in place of an aluminum bushing employed in the prior art. The CVD or DLC probe face is laser scribed to allow resistance trimming to match available trigger voltage signals and to reduce electrical aging.

  14. Cold cathode vacuum gauging system

    DOE Patents [OSTI]

    Denny, Edward C. (Knoxville, TN)

    2004-03-09

    A vacuum gauging system of the cold cathode type is provided for measuring the pressure of a plurality of separate vacuum systems, such as in a gas centrifuge cascade. Each casing is fitted with a gauge tube assembly which communicates with the vacuum system in the centrifuge casing. Each gauge tube contains an anode which may be in the form of a slender rod or wire hoop and a cathode which may be formed by the wall of the gauge tube. The tube is provided with an insulated high voltage connector to the anode which has a terminal for external connection outside the vacuum casing. The tube extends from the casing so that a portable magnet assembly may be inserted about the tube to provide a magnetic field in the area between the anode and cathode necessary for pressure measurements in a cold cathode-type vacuum gauge arrangement. The portable magnetic assembly is provided with a connector which engages the external high voltage terminal for providing power to the anode within in the gauge tube. Measurement is made in the same manner as the prior cold cathode gauges in that the current through the anode to the cathode is measured as an indication of the pressure. By providing the portable magnetic assembly, a considerable savings in cost, installation, and maintenance of vacuum gauges for pressure measurement in a gas centrifuge cascade is realizable.

  15. Cold cathode vacuum discharge tube

    DOE Patents [OSTI]

    Boettcher, G.E.

    1998-04-14

    A cold cathode vacuum discharge tube, and method for making same, with an interior surface of the trigger probe coated with carbon deposited by chemical vapor deposition (CVD) or diamond-like carbon (DLC) deposition are disclosed. Preferably a solid graphite insert is employed in the probe-cathode structure in place of an aluminum bushing employed in the prior art. The CVD or DLC probe face is laser scribed to allow resistance trimming to match available trigger voltage signals and to reduce electrical aging. 14 figs.

  16. Cold cathode vacuum discharge tube

    DOE Patents [OSTI]

    Boettcher, G.E.

    1998-03-10

    A cold cathode vacuum discharge tube, and method for making same, are disclosed with an interior surface of the trigger probe coated with carbon deposited by carbon vapor deposition (CVD) or diamond-like carbon (DLC) deposition. Preferably a solid graphite insert is employed in the probe-cathode structure in place of an aluminum bushing employed in the prior art. The CVD or DLC probe face is laser scribed to allow resistance trimming to match available trigger voltage signals and to reduce electrical aging. 15 figs.

  17. International workshop on cold neutron sources

    SciTech Connect (OSTI)

    Russell, G.J.; West, C.D. )

    1991-08-01

    The first meeting devoted to cold neutron sources was held at the Los Alamos National Laboratory on March 5--8, 1990. Cosponsored by Los Alamos and Oak Ridge National Laboratories, the meeting was organized as an International Workshop on Cold Neutron Sources and brought together experts in the field of cold-neutron-source design for reactors and spallation sources. Eighty-four people from seven countries attended. Because the meeting was the first of its kind in over forty years, much time was spent acquainting participants with past and planned activities at reactor and spallation facilities worldwide. As a result, the meeting had more of a conference flavor than one of a workshop. The general topics covered at the workshop included: Criteria for cold source design; neutronic predictions and performance; energy deposition and removal; engineering design, fabrication, and operation; material properties; radiation damage; instrumentation; safety; existing cold sources; and future cold sources.

  18. Observation of stars produced during cold fusion

    SciTech Connect (OSTI)

    Matsumoto, T. . Dept. of Nuclear Engineering)

    1992-12-01

    It has been indicated tht multiple-neutron nuclei such as quad-neutrons can be emitted during cold fusion. These multiple-neutrons might bombard the nuclei of materials outside a cold fusion cell to cause nuclear reactions. In this paper, observations of nuclear emulsions that were irradiated during a cold fusion experiment with heavy water and palladium foil are described. Various traces, like stars, showing nuclear reactions caused by the multiple-neutrons have been clearly observed.

  19. Evaporative cooling enhanced cold storage system

    DOE Patents [OSTI]

    Carr, P.

    1991-10-15

    The invention provides an evaporatively enhanced cold storage system wherein a warm air stream is cooled and the cooled air stream is thereafter passed into contact with a cold storage unit. Moisture is added to the cooled air stream prior to or during contact of the cooled air stream with the cold storage unit to effect enhanced cooling of the cold storage unit due to evaporation of all or a portion of the added moisture. Preferably at least a portion of the added moisture comprises water condensed during the cooling of the warm air stream. 3 figures.

  20. Evaporative cooling enhanced cold storage system

    DOE Patents [OSTI]

    Carr, Peter (Cary, NC)

    1991-01-01

    The invention provides an evaporatively enhanced cold storage system wherein a warm air stream is cooled and the cooled air stream is thereafter passed into contact with a cold storage unit. Moisture is added to the cooled air stream prior to or during contact of the cooled air stream with the cold storage unit to effect enhanced cooling of the cold storage unit due to evaporation of all or a portion of the added moisture. Preferably at least a portion of the added moisture comprises water condensed during the cooling of the warm air stream.

  1. R-Cold: Order (2013-CE-5354)

    Broader source: Energy.gov [DOE]

    DOE ordered R-Cold, Inc. to pay a $8,000 civil penalty after finding R-Cold had failed to certify that any basic models of walk-in cooler or freezer components comply with the applicable energy conservation standards.

  2. Gauss Sum Factorization with Cold Atoms

    SciTech Connect (OSTI)

    Gilowski, M.; Wendrich, T.; Mueller, T.; Ertmer, W.; Rasel, E. M. [Institut fuer Quantenoptik, Leibniz Universitaet Hannover, Welfengarten 1, D-30167 Hannover (Germany); Jentsch, Ch. [Astrium GmbH-Satellites, 88039 Friedrichshafen (Germany); Schleich, W. P. [Institut fuer Quantenphysik, Universitaet Ulm, Albert-Einstein-Allee 11, D-89081 Ulm (Germany)

    2008-01-25

    We report the first implementation of a Gauss sum factorization algorithm by an internal state Ramsey interferometer using cold atoms. A sequence of appropriately designed light pulses interacts with an ensemble of cold rubidium atoms. The final population in the involved atomic levels determines a Gauss sum. With this technique we factor the number N=263193.

  3. New analogies between extreme QCD and cold atoms

    SciTech Connect (OSTI)

    Nishida, Yusuke

    2012-08-15

    We discuss two new analogies between extreme QCD and cold atoms. One is the analogue of 'hard probes' in cold atoms. The other is the analogue of 'quark-hadron continuity' in cold atoms.

  4. Sandia National Laboratories: Cold War Warriors

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Cold War Warriors By Sue Major Holmes Thursday, April 28, 2016 The story of Sandia's decades in nuclear field testing Sandia videographer and documentarian Myra Buteau has produced a tribute to the nation's Cold War warriors. To watch Cold War Warriors on YouTube, click on the image above. Sandia video producer Myra Buteau sweeps her hand toward the top shelf of a bookcase stuffed with black cases of high-definition tapes. The biggest challenge in telling the story of Sandia's years of work in

  5. Linking Legacies: Connecting the Cold War Nuclear Weapons Production...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Cold War Nuclear Weapons Production Processes to Their Environmental Consequences Linking Legacies: Connecting the Cold War Nuclear Weapons Production Processes to Their ...

  6. High-Efficiency Commercial Cold Climate Heat Pump

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    High-Efficiency Commercial Cold Climate Heat Pump 2014 Building Technologies Office Peer ... performance cold climate commercial heat pump system 2) Execute a Technology Readiness ...

  7. High-Efficiency Commercial Cold Climate Heat Pump

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Commercial Cold Climate Heat Pump 2016 Building Technologies Office Peer Review Dr. Ahmad ... performance cold climate commercial heat pump system 2) Execute a Technology Readiness ...

  8. High-Efficiency Commercial Cold Climate Heat Pump

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Commercial Cold Climate Heat Pump 2015 Building Technologies Office Peer ... performance cold climate commercial heat pump system 2) Execute a Technology Readiness ...

  9. Baby It's Cold Outside: Best Practices for Chilly Climes (101...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Baby It's Cold Outside: Best Practices for Chilly Climes (101) Baby It's Cold Outside: Best Practices for Chilly Climes (101) November 5...

  10. Cold Bay Hot Spring Geothermal Area | Open Energy Information

    Open Energy Info (EERE)

    Cold Bay Hot Spring Geothermal Area Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Cold Bay Hot Spring Geothermal Area Contents 1 Area Overview 2 History and...

  11. Baby It's Cold Outside: Best Practices for Chilly Climes (101...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Baby It's Cold Outside: Best Practices for Chilly Climes (101) Baby It's Cold Outside: Best Practices for Chilly Climes (101) Better Buildings Residential Network Peer Exchange ...

  12. Centrality, Rapidity And Transverse-Momentum Dependence of Cold...

    Office of Scientific and Technical Information (OSTI)

    Centrality, Rapidity And Transverse-Momentum Dependence of Cold Nuclear Matter Effects on ... Title: Centrality, Rapidity And Transverse-Momentum Dependence of Cold Nuclear Matter ...

  13. Residential Cold Climate Heat Pump with Variable-Speed Technology...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Cold Climate Heat Pump with Variable-Speed Technology Residential Cold Climate Heat Pump with Variable-Speed Technology Purdue prototype system Purdue prototype system Unico ...

  14. Cold warriors target arms control (Journal Article) | SciTech...

    Office of Scientific and Technical Information (OSTI)

    Cold warriors target arms control Citation Details In-Document Search Title: Cold warriors target arms control While disagreements over the conflict in Bosnia have strained US ...

  15. Cold quark matter in compact stars

    SciTech Connect (OSTI)

    Franzon, B.; Fogaca, D. A.; Navarra, F. S.; Horvath, J. E.

    2013-03-25

    We used an equation of state for the cold quark matter to the study of properties of quark stars. We also discuss the absolute stability of quark matter and compute the mass-radius relation for self-bound stars.

  16. On a weak flavor for cold fusion

    SciTech Connect (OSTI)

    Chatterjee, L. . Dept. of Physics)

    1991-11-01

    In this paper the possibility of recent reports of cold fusion in deuterated metals being manifestations of primal nucleoweak reactions catalyzed by the host environment is investigated. Resulting experimental signatures are predicted.

  17. The possible hot nature of cold fusion

    SciTech Connect (OSTI)

    Kuehne, R.W. )

    1994-03-01

    Based on the model of micro hot fusion, the neutron emission rate of cold fusion is determined without the need for fine-tuning parameters. Moreover, the experimental conditions that are essential to reproduce fusion are determined. 84 refs.

  18. Toxicity evaluation and hazard review Cold Smoke

    SciTech Connect (OSTI)

    Archuleta, M.M.; Stocum, W.E.

    1993-12-01

    Cold Smoke is a dense white smoke produced by the reaction of titanium tetrachloride and aqueous ammonia aerosols. Early studies on the toxicity of this nonpyrotechnically generated smoke indicated that the smoke itself is essentially non-toxic (i.e. exhibits to systemic toxicity or organ damage due to exposure) under normal deployment conditions. The purpose of this evaluation was to review and summarize the recent literature data available on the toxicity of Cold Smoke, its chemical constituents, and its starting materials.

  19. Cold Facts staff tour JLab's cryogenic, SRF facilities (Cryogenic Society

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    of America, Cold Facts) | Jefferson Lab Cold Facts staff tour JLab's cryogenic, SRF facilities (Cryogenic Society of America, Cold Facts) External Link: http://www.cryogenicsociety.org/csa_highlights/cold_facts_tours_jlab_cryogenics_... By jlab_admin on Sat, 2012-05-05

  20. Cold versus hot fusion deuterium branching ratios

    SciTech Connect (OSTI)

    Fox, H.; Bass, R.

    1995-12-31

    A major source of misunderstanding of the nature of cold nuclear fusion has been the expectation that the deuterium branching ratios occurring within a palladium lattice would be consistent with the gas-plasma branching ratios. This misunderstanding has led to the concept of the dead graduate student, the 1989`s feverish but fruitless search for neutron emissions from cold fusion reactors, and the follow-on condemnation of the new science of cold fusion. The experimental facts are that in a properly loaded palladium lattice, the deuterium fusion produces neutrons at little above background, a greatly less-than-expected production of tritium (the tritium desert), and substantially more helium-4 than is observed in hot plasma physics. The experimental evidence is now compelling (800 reports of success from 30 countries) that cold nuclear fusion is a reality, that the branching ratios are unexpected, and that a new science is struggling to be recognized. Commercialization of some types of cold fusion devices has already begun.

  1. Cold atmospheric plasma in cancer therapy

    SciTech Connect (OSTI)

    Keidar, Michael; Shashurin, Alex; Volotskova, Olga; Ann Stepp, Mary; Srinivasan, Priya; Sandler, Anthony; Trink, Barry

    2013-05-15

    Recent progress in atmospheric plasmas has led to the creation of cold plasmas with ion temperature close to room temperature. This paper outlines recent progress in understanding of cold plasma physics as well as application of cold atmospheric plasma (CAP) in cancer therapy. Varieties of novel plasma diagnostic techniques were developed recently in a quest to understand physics of CAP. It was established that the streamer head charge is about 10{sup 8} electrons, the electrical field in the head vicinity is about 10{sup 7} V/m, and the electron density of the streamer column is about 10{sup 19} m{sup ?3}. Both in-vitro and in-vivo studies of CAP action on cancer were performed. It was shown that the cold plasma application selectively eradicates cancer cells in-vitro without damaging normal cells and significantly reduces tumor size in-vivo. Studies indicate that the mechanism of action of cold plasma on cancer cells is related to generation of reactive oxygen species with possible induction of the apoptosis pathway. It is also shown that the cancer cells are more susceptible to the effects of CAP because a greater percentage of cells are in the S phase of the cell cycle.

  2. Cold Climates Heat Pump Design Optimization

    SciTech Connect (OSTI)

    Abdelaziz, Omar [ORNL] [ORNL; Shen, Bo [ORNL] [ORNL

    2012-01-01

    Heat pumps provide an efficient heating method; however they suffer from sever capacity and performance degradation at low ambient conditions. This has deterred market penetration in cold climates. There is a continuing effort to find an efficient air source cold climate heat pump that maintains acceptable capacity and performance at low ambient conditions. Systematic optimization techniques provide a reliable approach for the design of such systems. This paper presents a step-by-step approach for the design optimization of cold climate heat pumps. We first start by describing the optimization problem: objective function, constraints, and design space. Then we illustrate how to perform this design optimization using an open source publically available optimization toolbox. The response of the heat pump design was evaluated using a validated component based vapor compression model. This model was treated as a black box model within the optimization framework. Optimum designs for different system configurations are presented. These optimum results were further analyzed to understand the performance tradeoff and selection criteria. The paper ends with a discussion on the use of systematic optimization for the cold climate heat pump design.

  3. Cold fusion observed with ordinary water

    SciTech Connect (OSTI)

    Matsumoto, T. )

    1990-05-01

    This paper describes a cold fusion electrolysis experiment using ordinary water. A Ge(Li) detector is used to observe signals up to {approx}130 keV; these signals show the occurrence of fusion reactions in ordinary water. The mechanism for the emission of radiation is discussed by the Nattoh model.

  4. Interference phenomena observed during cold fusion

    SciTech Connect (OSTI)

    Matsumoto, T. )

    1992-03-01

    In this paper the interference phenomena of waves observed during a cold fusion experiment are described. Nuclear emissions have successfully recorded two different interference phenomena of waves from an electrolyzing cell. It is inferred that the waves might be gravitational and antigravitational waves, which can be expected to be radiated from gravity decays of quad-neutrons.

  5. Cold fusion studies in the USSR

    SciTech Connect (OSTI)

    Tsarev, V.A. ); Worledge, D.H. )

    1992-08-01

    In this paper work presented at the first Soviet National Conference on Cold Nuclear Fusion, which took place in March 1991 in Dubna and Moscow, is reviewed. In addition to an integrated view of the experimental and theoretical work, a description is given of some additional contributions that had appeared in the Soviet literature before the conference.

  6. Cold fusion; The story behind the headlines

    SciTech Connect (OSTI)

    Ault, M.R.

    1991-06-01

    This article looks at the cold fusion issue which got a lot of attention in 1989. It provides interesting background information, a brief explanation of the experimental methods and problems encountered, and the basis for some of the controversy. The current state of the research effort is also outlined.

  7. Neutron measurements in search of cold fusion

    SciTech Connect (OSTI)

    Anderson, R.E.; Goulding, C.A.; Johnson, M.W.; Butterfield, K.B.; Gottesfeld, S.; Baker, D.A.; Springer, T.E.; Garzon, F.H.; Bolton, R.D.; Leonard, E.M.; Chancellor, T. )

    1991-05-10

    We have conducted a search for neutron emission from cold fusion systems of the electrochemical type and, to a lesser extent, the high-pressure gas cell type. Using a high-efficiency well counter and an NE 213 scintillator, the experiments were conducted on the earth's surface and in a shielded cave approximately 50 ft underground. After approximately 6500 h of counting time, we have obtained no evidence for cold fusion processes leading to neutron production. However, we have observed all three types of neutron data that have been presented as evidence for cold fusion: large positive fluctuations in the neutron counting rate, weak peaks near 2.5 MeV in the neutron energy spectrum, and bursts of up to 140 neutrons in 500-{mu}s intervals. The data were obtained under circumstances that clearly show our results to be data encountered as a part of the naturally occurring neutron background, which is due primarily to cosmic rays. Thus, observing these types of data does not, of itself, provide evidence for the existence of cold fusion processes. Artifacts in the data that were due to counter misbehavior were also observed to lead to long-term neutron bursts'' whose time duration varied from several hours to several days. We conclude that any experiments which attempt to observed neutron emission must include strong steps to ensure that the experiments deal adequately with both cosmic-ray processes and counter misbehavior.

  8. Could spectator electrons legalize cold fusion

    SciTech Connect (OSTI)

    Chatterjee, L. . Dept. of Physics)

    1990-12-01

    In this paper the possibility of spectator electrons driving cold d-d fusion in condensed matter to an observation threshold is considered, along with the consequences on the branching ratio of the exit channels. The intrinsic dominance of the t-p channel due to the increased phase space is demonstrated.

  9. Strip edge cracking simulation in cold rolling

    SciTech Connect (OSTI)

    Hubert, C.; Dubar, L.; Dubar, M.; Dubois, A.

    2011-01-17

    This research work focuses on a specific defect which occurs during cold rolling of steel strips: edge-serration. Investigations on the industrial processes have led to the conclusion that this defect is the result of the edge-trimming and cold rolling sequences. The aim of this research work is to analyze the effect of the cutting process and the cold rolling on cracks occurrence, especially on strip edges.This study is performed using an experimental testing stand called Upsetting Rolling Test (URT). It allows to reproduce cold rolling contact parameters such as forward slip, reduction ratio and friction coefficients. Specimens sampled near trimmed industrial strip edges are deformed using the URT stand. Two sets of specimens with different stress states, obtained by annealing, are submitted to two reduction passes with extreme forward slips.Scanning electron microscopy observations added to 3D optical surface profiler topographies show that on one hand, forward slip has a major effect on cracks opening. On the other hand, cracks opening decreases according to high roll strip speed gradient. Concerning the heat-treated specimens, no crack appeared after all reduction passes, showing a large influence of the cutting process and consequently of the local stress state in the vicinity of the burnish and fracture regions.

  10. Nuclear waste vitrification efficiency: cold cap reactions

    SciTech Connect (OSTI)

    Hrma, Pavel R.; Kruger, Albert A.; Pokorny, Richard

    2012-12-15

    The cost and schedule of nuclear waste treatment and immobilization are greatly affected by the rate of glass production. Various factors influence the performance of a waste-glass melter. One of the most significant, and also one of the least understood, is the process of batch melting. Studies are being conducted to gain fundamental understanding of the batch reactions, particularly those that influence the rate of melting, and models are being developed to link batch makeup and melter operation to the melting rate. Batch melting takes place within the cold cap, i.e., a batch layer floating on the surface of molten glass. The conversion of batch to glass consists of various chemical reactions, phase transitions, and diffusion-controlled processes. These include water evaporation (slurry feed contains as high as 60% water), gas evolution, the melting of salts, the formation of borate melt, reactions of borate melt with molten salts and with amorphous oxides (Fe2O3 and Al2O3), the formation of intermediate crystalline phases, the formation of a continuous glass-forming melt, the growth and collapse of primary foam, and the dissolution of residual solids. To this list we also need to add the formation of secondary foam that originates from molten glass but accumulates on the bottom of the cold cap. This study presents relevant data obtained for a high-level-waste melter feed and introduces a one-dimensional (1D) mathematical model of the cold cap as a step toward an advanced three-dimensional (3D) version for a complete model of the waste glass melter. The 1D model describes the batch-to-glass conversion within the cold cap as it progresses in a vertical direction. With constitutive equations and key parameters based on measured data, and simplified boundary conditions on the cold-cap interfaces with the glass melt and the plenum space of the melter, the model provides sensitivity analysis of the response of the cold cap to the batch makeup and melter conditions. The model demonstrates that batch foaming has a decisive influence on the rate of melting. Understanding the dynamics of the foam layer at the bottom of the cold cap and the heat transfer through it appears crucial for a reliable prediction of the rate of melting as a function of the melter-feed makeup and melter operation parameters. Although the study is focused on a batch for waste vitrification, the authors expect that the outcome will also be relevant for commercial glass melting.

  11. NUCLEAR WASTE VITRIFICATION EFFICIENCY COLD CAP REACTIONS

    SciTech Connect (OSTI)

    KRUGER AA; HRMA PR; POKORNY R

    2011-07-29

    The cost and schedule of nuclear waste treatment and immobilization are greatly affected by the rate of glass production. Various factors influence the performance of a waste-glass melter. One of the most significant, and also one of the least understood, is the process of batch melting. Studies are being conducted to gain fundamental understanding of the batch reactions, particularly those that influence the rate of melting, and models are being developed to link batch makeup and melter operation to the melting rate. Batch melting takes place within the cold cap, i.e., a batch layer floating on the surface of molten glass. The conversion of batch to glass consists of various chemical reactions, phase transitions, and diffusion-controlled processes. These include water evaporation (slurry feed contains as high as 60% water), gas evolution, the melting of salts, the formation of borate melt, reactions of borate melt with molten salts and with amorphous oxides (Fe{sub 2}O{sub 3} and Al{sub 2}O{sub 3}), the formation of intermediate crystalline phases, the formation of a continuous glass-forming melt, the growth and collapse of primary foam, and the dissolution of residual solids. To this list we also need to add the formation of secondary foam that originates from molten glass but accumulates on the bottom of the cold cap. This study presents relevant data obtained for a high-level-waste melter feed and introduces a one-dimensional (1D) mathematical model of the cold cap as a step toward an advanced three-dimensional (3D) version for a complete model of the waste glass melter. The 1D model describes the batch-to-glass conversion within the cold cap as it progresses in a vertical direction. With constitutive equations and key parameters based on measured data, and simplified boundary conditions on the cold-cap interfaces with the glass melt and the plenum space of the melter, the model provides sensitivity analysis of the response of the cold cap to the batch makeup and melter conditions. The model demonstrates that batch foaming has a decisive influence on the rate of melting. Understanding the dynamics of the foam layer at the bottom of the cold cap and the heat transfer through it appears crucial for a reliable prediction of the rate of melting as a function of the melter-feed makeup and melter operation parameters. Although the study is focused on a batch for waste vitrification, the authors expect that the outcome will also be relevant for commercial glass melting.

  12. Centrality, Rapidity And Transverse-Momentum Dependence of Cold...

    Office of Scientific and Technical Information (OSTI)

    of Cold Nuclear Matter Effects on JPsi Production in D Au, Cu Cu And Au Au Collisions at ... of Cold Nuclear Matter Effects on JPsi Production in D Au, Cu Cu And Au Au Collisions at ...

  13. Improving Fuel Economy When the Weather's Cold | Department of...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Fuel Economy When the Weather's Cold Improving Fuel Economy When the Weather's Cold February 25, 2014 - 9:49am Addthis Make sure your car is ready for spring snowstorms. | Photo...

  14. Improving Fuel Economy When the Weather's Cold | Department of...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Improving Fuel Economy When the Weather's Cold Improving Fuel Economy When the Weather's Cold February 25, 2014 - 9:49am Addthis Make sure your car is ready for spring snowstorms....

  15. The temperature dependence of ultra-cold neutron wall losses...

    Office of Scientific and Technical Information (OSTI)

    Title: The temperature dependence of ultra-cold neutron wall losses in material bottles coated with deuterated polystryene Ultra-cold neutrons (UCN) from the LANSCE super-thermal ...

  16. Baby It's Cold Outside: Best Practices for Chilly Climes (101)

    Broader source: Energy.gov [DOE]

    Better Buildings Residential Network Peer Exchange Call Series: Baby It's Cold Outside: Best Practices for Chilly Climes (101)

  17. Advanced Composite Materials for Cold and Cryogenic Hydrogen...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    11:30 Breakout Session II - Processing, Characterization, and Analysis Composite manufacturing processes suitable for cold cryogenic applications Material ...

  18. Builders Challenge Guide to 40% Whole-House Energy Savings in the Cold and Very Cold Climate – Volume 12

    SciTech Connect (OSTI)

    Pacific Northwest National Laboratory

    2011-02-01

    This document describes measures builders can use to construct homes that have whole-house energy savings of 40% in the cold and very cold climate region of the United States.

  19. Palladium metallurgy and cold fusion; Some remarks

    SciTech Connect (OSTI)

    Murr, L.E. )

    1990-04-01

    In this paper the recent confusion surrounding claims for the observation of cold fusion involving palladium electrodes in electrochemical cells containing deuterium might be clarified to some extent if the palladium metallurgy, particularly in the context of fundamental microstructures, are accurately defined. Both the palladium/hydrogen and palladium/deuterium systems have been extensively investigated, and it is asserted more than two decades ago that the palladium/hydrogen system was perhaps the most extensively, experimentally investigated metal/gas system. Ordinary hydrogen absorbed in palladium fused to form helium, while in the 1940's Wilner actually observed the fusion reaction at the center of the current cold fusion controversy: d + d {yields} {sup 3}He + n (where d = {sup 2}H represents a deuteron, and n is a neutron). In the experiment by Wilner, a deuterium-saturated palladium sheet was bombarded with accelerated deuterons. The product neutrons (n) were slowed by paraffin wax and detected by the activation of silver.

  20. Cryogenic target formation using cold gas jets

    DOE Patents [OSTI]

    Hendricks, Charles D. [Livermore, CA

    1980-02-26

    A method and apparatus using cold gas jets for producing a substantially uniform layer of cryogenic materials on the inner surface of hollow spherical members having one or more layers, such as inertially imploded targets. By vaporizing and quickly refreezing cryogenic materials contained within a hollow spherical member, a uniform layer of the materials is formed on an inner surface of the spherical member. Basically the method involves directing cold gas jets onto a spherical member having one or more layers or shells and containing the cryogenic material, such as a deuterium-tritium (DT) mixture, to freeze the contained material, momentarily heating the spherical member so as to vaporize the contained material, and quickly refreezing the thus vaporized material forming a uniform layer of cryogenic material on an inner surface of the spherical member.

  1. Experiments of one-point cold fusion

    SciTech Connect (OSTI)

    Matsumoto, Takaaki )

    1993-11-01

    Experiments of one-point cold fusion have been performed by electrical discharging in ordinary and heavy water mixed with 0.6 mol/l potassium carbonate. A platinum pin anode was located perpendicular to a copper plate cathode. After discharge, the surfaces of the copper plates were examined by an optical microscope. Many ring spots caused by gravity decay of single and di-neutrons were separately distributed on the plates. Furthermore, several kinds of traces that might be produced by itonic hydrogen clusters and by tiny black and white holes were observed. The mechanisms of cold fusion by electrical discharge are also discussed in terms of the Nattoh model. 13 refs., 12 figs.

  2. Cold fusion catalyzed by muons and electrons

    SciTech Connect (OSTI)

    Kulsrud, R.M.

    1990-10-01

    Two alternative methods have been suggested to produce fusion power at low temperature. The first, muon catalyzed fusion or MCF, uses muons to spontaneously catalyze fusion through the muon mesomolecule formation. Unfortunately, this method fails to generate enough fusion energy to supply the muons, by a factor of about ten. The physics of MCF is discussed, and a possible approach to increasing the number of MCF fusions generated by each muon is mentioned. The second method, which has become known as Cold Fusion,'' involves catalysis by electrons in electrolytic cells. The physics of this process, if it exists, is more mysterious than MCF. However, it now appears to be an artifact, the claims for its reality resting largely on experimental errors occurring in rather delicate experiments. However, a very low level of such fusion claimed by Jones may be real. Experiments in cold fusion will also be discussed.

  3. Cryogenic target formation using cold gas jets

    DOE Patents [OSTI]

    Hendricks, C.D.

    1980-02-26

    A method and apparatus using cold gas jets for producing a substantially uniform layer of cryogenic materials on the inner surface of hollow spherical members having one or more layers, such as inertially imploded targets are disclosed. By vaporizing and quickly refreezing cryogenic materials contained within a hollow spherical member, a uniform layer of the materials is formed on an inner surface of the spherical member. Basically the method involves directing cold gas jets onto a spherical member having one or more layers or shells and containing the cryogenic material, such as a deuterium-tritium (DT) mixture, to freeze the contained material, momentarily heating the spherical member so as to vaporize the contained material, and quickly refreezing the thus vaporized material forming a uniform layer of cryogenic material on an inner surface of the spherical member. 4 figs.

  4. Cryogenic target formation using cold gas jets

    DOE Patents [OSTI]

    Hendricks, Charles D. (Livermore, CA)

    1981-01-01

    A method and apparatus using cold gas jets for producing a substantially uniform layer of cryogenic materials on the inner surface of hollow spherical members having one or more layers, such as inertially imploded targets. By vaporizing and quickly refreezing cryogenic materials contained within a hollow spherical member, a uniform layer of the materials is formed on an inner surface of the spherical member. Basically the method involves directing cold gas jets onto a spherical member having one or more layers or shells and containing the cryogenic material, such as a deuterium-tritium (DT) mixture, to freeze the contained material, momentarily heating the spherical member so as to vaporize the contained material, and quickly refreezing the thus vaporized material forming a uniform layer of cryogenic material on an inner surface of the spherical member.

  5. Cold worked ferritic alloys and components

    DOE Patents [OSTI]

    Korenko, Michael K.

    1984-01-01

    This invention relates to liquid metal fast breeder reactor and steam generator precipitation hardening fully ferritic alloy components which have a microstructure substantially free of the primary precipitation hardening phase while having cells or arrays of dislocations of varying population densities. It also relates to the process by which these components are produced, which entails solution treating the alloy followed by a final cold working step. In this condition, the first significant precipitation hardening of the component occurs during high temperature use.

  6. Combined cold compressor/ejector helium refrigerator

    DOE Patents [OSTI]

    Brown, Donald P.

    1985-01-01

    A refrigeration apparatus having an ejector operatively connected with a cold compressor to form a two-stage pumping system. This pumping system is used to lower the pressure, and thereby the temperature of a bath of boiling refrigerant (helium). The apparatus as thus arranged and operated has substantially improved operating efficiency when compared to other processes or arrangements for achieving a similar low pressure.

  7. Possible ways to achieve cold fusion. III

    SciTech Connect (OSTI)

    Tisenko, Yu.A.

    1994-12-01

    It is suggested that a deuteron {open_quotes}microaccelerator{close_quotes} be constructed in order to achieve cold fusion. This accelerator would operate on the basis of a glow discharge near a charged Pd-D powder grain in low-density gaseous D{sub 2}. Possible parameters of such an accelerator are calculated. The heat released as a result of fusion is estimated, as is the intensity of the deuteron flux.

  8. EPRI News; Update on cold fusion

    SciTech Connect (OSTI)

    Douglas, J.

    1991-05-01

    This paper reports that from instant sensation to virtual pariah, cold fusion has had a stormy history since two University of Utah researchers first announced its discovery in March 1989. Research into this mysterious phenomenon has been plagued both by technical difficulties in replicating experimental results and by sometimes bitter controversy over scientific standards and personal credibility. Now, in a somewhat calmer atmosphere, significant progress is being made through experiments that are reproducible over long periods of time and under a variety of conditions. These experiments indicate that nuclear reactions may indeed occur at room temperature in a crystal lattice in ways not understood before. It's time we stopped calling these reactions cold fusion, says David Worledge, EPRI coordinator of research in this area. There is now good evidence that cold nuclear reaction of some sort are taking place, but also growing indications that they aren't conventional deuterium-deuterium fusion, as first assumed. Also, the cold nuclear reactions inferred from the neutrons that have been detected are not numerous enough to be responsible for the excess heat production still being reported in some experiments. In their original work, University of Utah scientist Martin Fleischmann and Stanley Pons used a simple laboratory apparatus consisting of a palladium rod surrounded by a platinum coil and immersed in heavy water. They reported that when a small electric current was applied to the cells, deuterium nuclei from the heavy water were driven into the palladium rod, where they were held in the metal lattice and apparently fused, producing 4 watts of heat for each watt of electric power supplied.

  9. Review of the `cold fusion` effect

    SciTech Connect (OSTI)

    Storms, E.

    1996-09-01

    More than 190 studies reporting evidence for the `cold fusion` effect are evaluated. New work has answered criticisms by eliminating many of the suggested errors. Evidence for large and reproducible energy generation as well as various nuclear reactions, in addition to fusion, from a variety of environments and methods in accumulating. The field can no longer be dismissed by invoking obvious error or prosaic explanations. 192 refs., 12 figs., 10 tabs.

  10. Possible resonant mechanism of cold fusion

    SciTech Connect (OSTI)

    Zakowicz, W. )

    1991-01-01

    This paper discusses a hypothesis of resonant deuteron-deuteron interaction under cold fusion conditions. The resonance may exist due to a combination of an attractive nuclear interaction at close distances and a repulsive Coulomb potential at large distances. The energy of such resonances may be very low. This effect may increase the reaction cross section and reaction rates in high-density deuteron hydrides.

  11. Cold Vacuum Drying Facility hazard analysis report

    SciTech Connect (OSTI)

    Krahn, D.E.

    1998-02-23

    This report describes the methodology used in conducting the Cold Vacuum Drying Facility (CVDF) hazard analysis to support the CVDF phase 2 safety analysis report (SAR), and documents the results. The hazard analysis was performed in accordance with DOE-STD-3009-94, Preparation Guide for US Department of Energy Nonreactor Nuclear Facility Safety Analysis Reports, and implements the requirements of US Department of Energy (DOE) Order 5480.23, Nuclear Safety Analysis Reports.

  12. Combined cold compressor/ejector helium refrigerator

    DOE Patents [OSTI]

    Brown, D.P.

    1984-06-05

    A refrigeration apparatus having an ejector operatively connected with a cold compressor to form a two-stage pumping system. This pumping system is used to lower the pressure, and thereby the temperature of a bath of boiling refrigerant (helium). The apparatus as thus arranged and operated has substantially improved operating efficiency when compared to other processes or arrangements for achieving a similar low pressure.

  13. Cold moderator test facilities working group

    SciTech Connect (OSTI)

    Bauer, Guenter S.; Lucas, A. T.

    1997-09-01

    The working group meeting was chaired by Bauer and Lucas.Testing is a vital part of any cold source development project. This applies to specific physics concept verification, benchmarking in conjunction with computer modeling and engineering testing to confirm the functional viability of a proposed system. Irradiation testing of materials will always be needed to continuously extend a comprehensive and reliable information database. An ever increasing worldwide effort to enhance the performance of reactor and accelerator based neutron sources, coupled with the complexity and rising cost of building new generation facilities, gives a new dimension to cold source development and testing programs. A stronger focus is now being placed on the fine-tuning of cold source design to maximize its effectiveness in fully exploiting the facility. In this context, pulsed spallation neutron sources pose an extra challenge due to requirements regarding pulse width and shape which result from a large variety of different instrument concepts. The working group reviewed these requirements in terms of their consequences on the needs for testing equipment and compiled a list of existing and proposed facilities suitable to carry out the necessary development work.

  14. Hadronization measurements in cold nuclear matter

    SciTech Connect (OSTI)

    Dupre, Raphael

    2015-05-01

    Hadronization is the non-perturbative process of QCD by which partons become hadrons. It has been studied at high energies through various processes, we focus here on the experiments of lepto-production of hadrons in cold nuclear matter. By studying the dependence of observables to the atomic number of the target, these experimentscan give information on the dynamic of the hadronization at the femtometer scale. In particular, we will present preliminary results from JLab Hall B (CLAS collaboration), which give unprecedented statistical precision. Then, we will present results of a phenomenological study showing how HERMES data can be described with pure energyloss models.

  15. Barrier Distributions for Cold-Fusion Reactions

    SciTech Connect (OSTI)

    Ikezoe, Hiroshi; Mitsuoka, Shin-ichi; Nishio, Katsuhisa; Tsuruta, Kaoru; Watanabe, Yutaka; Jeong, Sunchan; Satou, Ken-ichiro

    2006-08-14

    Coulomb barrier distributions for the capture process in the cold fusion reactions for 48Ti, 54Cr, 56Fe, 64Ni, 70Zn projectiles incident on 208Pb target are obtained by the measurement of the quasi-elastic scattering cross sections at backward angles. The obtained barrier distributions are compared with the result of a coupled-channels calculation. It is found that the barrier distributions are well reproduced by the calculation taking account of the coupling of one phonon of the quadrupole vibration for these projectile nuclei and two phonons of the octupole vibration for 208Pb.

  16. Methanation process utilizing split cold gas recycle

    DOE Patents [OSTI]

    Tajbl, Daniel G.; Lee, Bernard S.; Schora, Jr., Frank C.; Lam, Henry W.

    1976-07-06

    In the methanation of feed gas comprising carbon monoxide and hydrogen in multiple stages, the feed gas, cold recycle gas and hot product gas is mixed in such proportions that the mixture is at a temperature sufficiently high to avoid carbonyl formation and to initiate the reaction and, so that upon complete reaction of the carbon monoxide and hydrogen, an excessive adiabatic temperature will not be reached. Catalyst damage by high or low temperatures is thereby avoided with a process that utilizes extraordinarily low recycle ratios and a minimum of investment in operating costs.

  17. Axions as hot and cold dark matter

    SciTech Connect (OSTI)

    Jeong, Kwang Sik; Kawasaki, Masahiro; Takahashi, Fuminobu E-mail: kawasaki@icrr.u-tokyo.ac.jp

    2014-02-01

    The presence of a hot dark matter component has been hinted at 3? by a combination of the results from different cosmological observations. We examine a possibility that pseudo Nambu-Goldstone bosons account for both hot and cold dark matter components. We show that the QCD axions can do the job for the axion decay constant f{sub a}?

  18. T-661: ColdFusion Security Hotfix | APSB11-14, ColdFusion Important Update

    Broader source: Energy.gov [DOE]

    Vulnerabilities have been identified in ColdFusion 9.0.1 and earlier versions for Windows, Macintosh and UNIX. These vulnerabilities could lead to a cross-site request forgery (CSRF) or a remote denial-of-service (DoS). Adobe recommends users update their product installation using the instructions provided below.

  19. Actively controlling coolant-cooled cold plate configuration

    DOE Patents [OSTI]

    Chainer, Timothy J.; Parida, Pritish R.

    2015-07-28

    A method is provided to facilitate active control of thermal and fluid dynamic performance of a coolant-cooled cold plate. The method includes: monitoring a variable associated with at least one of the coolant-cooled cold plate or one or more electronic components being cooled by the cold plate; and dynamically varying, based on the monitored variable, a physical configuration of the cold plate. By dynamically varying the physical configuration, the thermal and fluid dynamic performance of the cold plate are adjusted to, for example, optimally cool the one or more electronic components, and at the same time, reduce cooling power consumption used in cooling the electronic component(s). The physical configuration can be adjusted by providing one or more adjustable plates within the coolant-cooled cold plate, the positioning of which may be adjusted based on the monitored variable.

  20. Searching for tiny black holes during cold fusion

    SciTech Connect (OSTI)

    Matsumoto, T. . Dept. of Nuclear Engineering)

    1992-09-01

    A previous technical note suggests that cold fusion is a small-scale simulation of events that occur in cold stars far-away in the universe. Therefore, it is expected that tiny black holes might be produced during cold fusion. In this paper, a search for tiny black holes whose traces might have been recorded on nuclear emulsions is described. Several traces suggesting the production and evaporation of tiny black holes have been successfully observed.

  1. Assessment of cold-climate environmental research priorities

    SciTech Connect (OSTI)

    States, J.B.

    1983-04-01

    The Environmental Protection Agency (EPA) has consistently recognized that cold regions pose unique environmental problems. This report sets forth the conceptual framework and research plans for several high priority research areas. It provides the fundamental basis for implementation of the EPA Cold-Climate Environmental Research Program. This three- to five-year program encompasses both short- and long-term research of high relevance to the EPA and to the cold regions that it serves.

  2. Independent Oversight Review, Hanford K Basin and Cold Vacuum...

    Broader source: Energy.gov (indexed) [DOE]

    Hanford K Basin and Cold Vacuum Drying Facility Found Fuel Multi-Canister Overpack Operations This report provides the results of an independent oversight review of operations...

  3. Split-System Cold Climate Heat Pump | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Split-System Cold Climate Heat Pump Split-System Cold Climate Heat Pump Photo of the prototype cold climate heat pump outdoor unit, installed at the Ohio field test site in January 2015. <br />Credit: Oak Ridge National Laboratory Photo of the prototype cold climate heat pump outdoor unit, installed at the Ohio field test site in January 2015. Credit: Oak Ridge National Laboratory Lead Performer: Oak Ridge National Laboratory - Oak Ridge, TN Partners: -- Unico Inc. - St. Louis, MO --

  4. Data Collection for Improved Cold Temperature Thermal Modeling...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Modeling and Strategy Development Data Collection for Improved Cold Temperature Thermal Modeling and Strategy Development 2011 DOE Hydrogen and Fuel Cells Program, and Vehicle ...

  5. Laboratory's role in Cold War nuclear weapons testing program...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    70th anniversary lecture Laboratory's role in Cold War nuclear weapons testing program focus of next 70th anniversary lecture Lab's role in the development of nuclear weapons ...

  6. Cold-Start Emissions Control in Hybrid Vehicles Equipped with...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Adsorber for Hydrocarbons and NOx Cold-Start Emissions Control in Hybrid Vehicles Equipped with a Passive Adsorber for Hydrocarbons and NOx Reports results from study of ...

  7. Tracing And Quantifying Magmatic Carbon Discharge In Cold Groundwaters...

    Open Energy Info (EERE)

    Tracing And Quantifying Magmatic Carbon Discharge In Cold Groundwaters- Lessons Learned From Mammoth Mountain, USA Jump to: navigation, search OpenEI Reference LibraryAdd to...

  8. Tracing And Quantifying Magmatic Carbon Discharge In Cold Groundwaters...

    Open Energy Info (EERE)

    Journal Article: Tracing And Quantifying Magmatic Carbon Discharge In Cold Groundwaters- Lessons Learned From Mammoth Mountain, Usa Abstract A major campaign to quantify the...

  9. COLD-PLASMA ASSISTED GRAFTING OF PAPER

    SciTech Connect (OSTI)

    Gaiolas, C.; Costa, A. P.; Nunes, M.; Silva, M. J. Santos; Belgacem, M. N.

    2008-08-28

    The treatment of cellulose with cold-plasma in the presence of two silanes (vinyltrimethoxysilane and {gamma}-methacryloxypropyltrimethoxysilane) was found to be efficient in grafting of cellulose macromolecules. The occurrence of the grafting was proved by contact angle measurement, ESCA and SEM. Thus, after solvent extraction of the modified substrates, in order to remove unbounded grafts, the polar component of the surface energy of treated samples decreased from 23 mJ/m{sup 2} to practically zero. The ESCA spectra showed the appearance of two new peaks at 102 and 150 eV, relative to the presence of Si atoms and a substantial increase in C1 signal, attributed to the enrichment of the surface by C-H moieties borne by the silanes.

  10. The Cold War is over. What now?

    SciTech Connect (OSTI)

    Hecker, S.S.

    1995-05-01

    As you might imagine, the end of the Cold War has elicited an intense reexamination of the roles and missions of institutions such as the Los Alamos National Laboratory. During the past few years, the entire defense establishment has undergone substantial consolidation, with a concomitant decrease in support for research and development, including in areas such as materials. The defense industry is down-sizing at a rapid pace. Even universities have experienced significant funding cutbacks from the defense community. I view this as a profound time in history, bringing changes encompassing much more than just the defense world. In fact, support for science and technology is being reexamined across the board more completely than at any other time since the end of World War II.

  11. Method for cold stable biojet fuel

    DOE Patents [OSTI]

    Seames, Wayne S.; Aulich, Ted

    2015-12-08

    Plant or animal oils are processed to produce a fuel that operates at very cold temperatures and is suitable as an aviation turbine fuel, a diesel fuel, a fuel blendstock, or any fuel having a low cloud point, pour point or freeze point. The process is based on the cracking of plant or animal oils or their associated esters, known as biodiesel, to generate lighter chemical compounds that have substantially lower cloud, pour, and/or freeze points than the original oil or biodiesel. Cracked oil is processed using separation steps together with analysis to collect fractions with desired low temperature properties by removing undesirable compounds that do not possess the desired temperature properties.

  12. Slurry fired heater cold-flow modelling

    SciTech Connect (OSTI)

    Moujaes, S.F.

    1983-07-01

    This report summarizes the experimental and theoretical work leading to the scale-up of the SRC-I Demonstration Plant slurry fired heater. The scale-up involved a theoretical model using empirical relations in the derivation, and employed variables such as flow conditions, liquid viscosity, and slug frequency. Such variables have been shown to affect the heat transfer characteristics ofthe system. The model assumes that, if all other variables remain constant, the heat transfer coefficient can be scaled up proportional to D/sup -2/3/ (D = inside diameter of the fired heater tube). All flow conditions, liquid viscosities, and pipe inclinations relevant to the demonstration plant have indicated a slug flow regime in the slurry fired heater. The annular and stratified flow regimes should be avoided to minimize the potential for excessive pipe erosion and to decrease temperature gradients along the pipe cross section leading to coking and thermal stresses, respectively. Cold-flow studies in 3- and 6.75-in.-inside-diameter (ID) pipes were conducted to determine the effect of scale-up on flow regime, slug frequency, and slug dimensions. The developed model assumes that conduction heat transfer occurs through the liquid film surrounding the gas slug and laminar convective heat transfer to the liquid slug. A weighted average of these two heat transfer mechanisms gives a value for the average pipe heat transfer coefficient. The cold-flow work showed a decrease in the observed slug frequency between the 3- and 6.75-ID pipes. Data on the ratio of gas to liquid slug length in the 6.75-in. pipe are not yet complete, but are expected to yield generally lower values than those obtained in the 3-in. pipe; this will probably affect the scale-up to demonstration plant conditions. 5 references, 15 figures, 7 tables.

  13. Cold fusion: The scientific fiasco of the century

    SciTech Connect (OSTI)

    Huizenga, J.R.

    1992-01-01

    A summary of the cold fusion fiasco, its history, claims, experimental questions, are presented in this book. The author gives in some detail good reasons why cold fusion has been disregarded by mainstream science. Disturbing questions about the behavior of scientific investigators and reactions to such events are raised.

  14. Microscopic observations of palladium used for cold fusion

    SciTech Connect (OSTI)

    Matsumoto, T. )

    1991-05-01

    This paper examines the microscopic structures of palladium metals used for cold fusion experiments. Tiny spot defects suggesting cold fusion have been observed in grain boundaries as the Nattoh model predicts. The relationship between these defects and a series of neutron busts and an indirect loop of hydrogen chain reactions are discussed.

  15. Observation of heavy elements produced during explosive cold fusion

    SciTech Connect (OSTI)

    Matsumoto, T.; Kurokawa, K. )

    1991-11-01

    This paper reports on many-body fusion reactions that may take place during cold fusion. Heavy elements are observed that might have been produced by such reactions during electrolysis of heavy water. Elements such as sodium, magnesium, aluminum, and zinc are observed inside grain-shaped defects in a palladium rod used in a cold fusion experiment.

  16. Data Collection for Improved Cold Temperature Thermal Modeling and Strategy

    Broader source: Energy.gov (indexed) [DOE]

    Development | Department of Energy 1 DOE Hydrogen and Fuel Cells Program, and Vehicle Technologies Program Annual Merit Review and Peer Evaluation PDF icon vss050_jehlik_2011_o.pdf More Documents & Publications Data Collection for Improved Cold Temperature Thermal Modeling Energy Management Strategies for Fast Battery Temperature Rise and Engine Efficiency Improvement at Very Cold Conditions

  17. Y-12, the Cold War, and nuclear weapons dismantlement „ Or:...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    the Cold War, and nuclear weapons dismantlement - Or: The Cold War and nuclear weapons dismantlement (title used in The Oak Ridger) The Cold War heated up over the years with such ...

  18. OTEC Cold Water Pipe-Platform Sub-System Dynamic Interaction...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    OTEC Cold Water Pipe-Platform Sub-System Dynamic Interaction Validation (OPPSDIV) OTEC Cold Water Pipe-Platform Sub-System Dynamic Interaction Validation (OPPSDIV) OTEC Cold Water ...

  19. Cold Nuclear Matter Effects at PHENIX

    SciTech Connect (OSTI)

    Wysocki, Matthew G; PHENIX, Collaboration

    2013-01-01

    While the study of the quark-gluon plasma has been the primary focus of the RHIC experiments, much work has also been done to understand so-called cold nuclear matter (CNM) eects through d+Au collisions where no hot plasma is produced. Eects such as nuclear shadowing, Cronin enhancement, and initial-state parton energy loss, among others, are not only interesting in their own right, but have direct implications on QGP-related measurements in A+A collisions. Recently PHENIX has measured CNM eects at midrapidity in s_NN = 200 GeV d+Au collisions. Measurements of reconstructed jets reveal the centrality dependence of both jet suppression and broadening of the away-side jet. Meanwhile, single electrons from heavy flavor decays exhibit enhancement, increasing with centrality, over a broad p_T range. J/psi and psi' modification have also been measured and are quite dierent in magnitude, in contrast with our expectations. The above results are presented here and compared to our present understanding of CNM effects.

  20. Finite Cosmology and a CMB Cold Spot

    SciTech Connect (OSTI)

    Adler, R.J.; Bjorken, J.D.; Overduin, J.M.; /Stanford U., HEPL

    2006-03-20

    The standard cosmological model posits a spatially flat universe of infinite extent. However, no observation, even in principle, could verify that the matter extends to infinity. In this work we model the universe as a finite spherical ball of dust and dark energy, and obtain a lower limit estimate of its mass and present size: the mass is at least 5 x 10{sup 23}M{sub {circle_dot}} and the present radius is at least 50 Gly. If we are not too far from the dust-ball edge we might expect to see a cold spot in the cosmic microwave background, and there might be suppression of the low multipoles in the angular power spectrum. Thus the model may be testable, at least in principle. We also obtain and discuss the geometry exterior to the dust ball; it is Schwarzschild-de Sitter with a naked singularity, and provides an interesting picture of cosmogenesis. Finally we briefly sketch how radiation and inflation eras may be incorporated into the model.

  1. Letter report: Cold crucible melter assessment

    SciTech Connect (OSTI)

    Elliott, M.L.

    1996-03-01

    One of the activities of the PNL Vitrification Technology Development (PVTD) Project is to assist the Tank Waste Remediation Systems (TWRS) Program in determining which melter systems should be performance tested for potential implementation in the high-level waste (HLW) vitrification plant. The Richland Operations Office (RL) has recommended that the Cold Crucible Melter (CCM) be evaluated as a candidate ``next generation`` melter. As a result, the CCM System Evaluation cost account was established under the PVTD Project so that the CCM could be initially assessed on a high-priority basis. This letter report summarizes a brief initial review and assessment of the CCM. Using the recommendations made in this document, Westinghouse Hanford Company (WHC) and RL will make a decision regarding the urgency of performance testing the CCM. If the decision is favorable, a subcontract will be negotiated for performance testing of a CCM using Hanford HLW simulants in a pilot-scale facility. Because of the aggressive nature of the schedule, the CCM evaluation was not rigorous. The evaluation consisted of a literature review and interviews with proponents of the technology during a recent trip to France. This letter report summarizes the evaluation and makes recommendations regarding further work in this area.

  2. Performance House -- A Cold Climate Challenge Home

    SciTech Connect (OSTI)

    Puttagunta, S.; Grab, J.; Williamson, J.

    2013-08-01

    Working with builder partners on a test homes allows for vetting of whole-house building strategies to eliminate any potential unintended consequences prior to implementing these solution packages on a production scale. To support this research, CARB partnered with Preferred Builders Inc. on a high-performance test home in Old Greenwich, CT. The philosophy and science behind the 2,700 ft2 'Performance House' was based on the premise that homes should be safe, healthy, comfortable, durable, efficient, and adapt with the homeowners. The technologies and strategies used in the 'Performance House' were not cutting-edge, but simply 'best practices practiced'. The focus was on simplicity in construction, maintenance, and operation. When seeking a 30% source energy savings targets over a comparable 2009 IECC code-built home in the cold climate zone, nearly all components of a home must be optimized. Careful planning and design are critical. To help builders and architects seeking to match the performance of this home, a step-by-step guide through the building shell components of DOE's Challenge Home are provided in a pictorial story book. The end result was a DOE Challenge Home that achieved a HERS Index Score of 20 (43 without PV, the minimum target was 55 for compliance). This home was also awarded the 2012 HOBI for Best Green Energy Efficient Home from the Home Builders & Remodelers Association of Connecticut.

  3. Premixed cold reaction cw laser nozzle

    SciTech Connect (OSTI)

    Hook, D.L.; Broadwell, J.E.

    1988-11-15

    This patent describes a combustor for a premixed cold reaction CW chemical laser. The combustor consists of: a combustion chamber, the combustion chamber containing reaction products forming heated primary gas having therein atomic species of an oxidizer, the combustion chamber directing the reaction products to an output plenum; wedges positioned downstream of the output plenum to form a plurality of primary nozzles, each of the primary nozzles having an input section, a throat section, and an output section, the sections forming a supersonic nozzle to output the reaction products as a supersonic gas; secondary injectors having supersonic jets therefrom, the secondary injectors being located on exit walls substantially parallel to the streamlines of the primary nozzles and located downstream of the throat section of the primary nozzles, the secondary injectors being arranged in substantially parallel rows in a streamwise direction, each of the rows having the secondary injectors therein, the secondary injectors in a row comprising groups of secondary injectors, a first group being proximal to the throat section and injecting a diluent, a second group of secondary injectors downstream of the first group and inputting a fuel therein. The secondary injectors are at an acute angle to the exit walls, the acuteness being in the downstream direction.

  4. Preliminary Market Assessment for Cold Climate Heat Pumps

    SciTech Connect (OSTI)

    Sikes, Karen; Khowailed, Gannate; Abdelaziz, Omar

    2011-09-01

    Cold climate heat pump (HP) technology is relevant to a substantial portion of the U.S. population, especially with more than one-third of U.S. housing stock concentrated in colder regions of the country and another 31% in the mixed-humid climate region. Specifically, it is estimated that in 2010 almost 1.37 million heating equipment units were shipped to the cold/very cold climate regions and that 1.41 million were shipped to the nation s mixed-humid region. On a national level, the trend in the last decade has indicated that shipments of gas furnaces have grown at a slower rate than HPs. This indicates a potential opportunity for the cold climate HP, a technology that may be initially slow to penetrate its potential market because of the less expensive operating and first costs of gas furnaces. Anticipated implementation of regional standards could also negatively affect gas furnace shipments, especially with the higher initial cost for more efficient gas furnaces. However, as of 2011, the fact that there are more than 500 gas furnace product models that already achieve the expected efficiency standard indicates that satisfying the regional standard will be a challenge but not an obstacle. A look at the heating fuel and equipment currently being used in the housing stock provides an insight into the competing equipment that cold climate HPs hope to replace. The primary target market for the cold climate HP is the 2.6 million U.S. homes using electric furnaces and HPs in the cold/very cold region. It is estimated that 4.75% of these homeowners either replace or buy new heating equipment in a given year. Accordingly, the project team could infer that the cold climate HP primary market is composed of 123,500 replacements of electric furnaces and conventional air-to-air HPs annually. A secondary housing market for the cold climate HP comprises homes in the mixed-humid region of the country that are using electric furnaces. Homes using gas furnaces across both the cold/very cold and mixed-humid regions represent another secondary market for the cold climate HP. The cold climate HP could also target as a secondary market homes across both the cold/very cold and mixed-humid regions that use propane and fuel oil as their primary heating fuel. The combined total of homes in these three secondary markets is 46 million, and we can also infer that about 2.2 million of these systems are replaced annually. When comparing heating equipment stock in 2001, 2005, and 2009 in the cold/very cold region of the country, it appears that gas furnaces are slowly losing market share and that electric furnaces and HPs are making gains. The fact that electricity-dependent heating equipment is rising in preference among homeowners in the colder regions of the country shows that future penetration of the cold climate HP holds promise. Accordingly, cold climate HP technology could achieve an attractive position, given certain favorable market conditions such as reaching a competitive cost point, strong federal incentives, a consistent level of reliable performance, and a product rollout by a credible market leader. The project team relied on payback analysis to estimate the potential market penetration for the cold climate HP in each of its primary and secondary markets. In this analysis, we assumed a $250 price premium for the cold climate HP over the baseline HP. Electricity and gas prices and emissions were based on the 2010 Buildings Energy Data Book. The average heating load was calculated as 25.2 MMBTU per year in the cold/very cold and mixed-humid regions of the United States. Typical installed costs were obtained from the technical document supporting the U.S. Department of Energy rulemaking. The analysis showed that the cold climate HP will have a 2.2 year payback period when replacing an existing electric HP in the colder regions of the nation. The cold climate HP will have a 6 year payback period when replacing gas furnaces in the same climate regions. Accordingly, we estimated that the cold climate HP will have a penetration ratio ranging between 5% and 35% in its potential primary and secondary markets, resulting in a total annual estimated shipment of 298,000 units to both targeted regions of the nation. Once the cold climate HP technology meets its potential market penetration, it would contribute to annual site energy savings of 3,664,405 MMBTU and a CO2 emission reduction of 470,000 Ton.

  5. High Flux Isotope Reactor cold neutron source reference design concept

    SciTech Connect (OSTI)

    Selby, D.L.; Lucas, A.T.; Hyman, C.R.

    1998-05-01

    In February 1995, Oak Ridge National Laboratory`s (ORNL`s) deputy director formed a group to examine the need for upgrades to the High Flux Isotope Reactor (HFIR) system in light of the cancellation of the Advanced neutron Source Project. One of the major findings of this study was that there was an immediate need for the installation of a cold neutron source facility in the HFIR complex. In May 1995, a team was formed to examine the feasibility of retrofitting a liquid hydrogen (LH{sub 2}) cold source facility into an existing HFIR beam tube. The results of this feasibility study indicated that the most practical location for such a cold source was the HB-4 beam tube. This location provides a potential flux environment higher than the Institut Laue-Langevin (ILL) vertical cold source and maximizes the space available for a future cold neutron guide hall expansion. It was determined that this cold neutron beam would be comparable, in cold neutron brightness, to the best facilities in the world, and a decision was made to complete a preconceptual design study with the intention of proceeding with an activity to install a working LH{sub 2} cold source in the HFIR HB-4 beam tube. During the development of the reference design the liquid hydrogen concept was changed to a supercritical hydrogen system for a number of reasons. This report documents the reference supercritical hydrogen design and its performance. The cold source project has been divided into four phases: (1) preconceptual, (2) conceptual design and testing, (3) detailed design and procurement, and (4) installation and operation. This report marks the conclusion of the conceptual design phase and establishes the baseline reference concept.

  6. Slow Mo Guys and Cold Spray | GE Global Research

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Slow Mo Guys and Cold Spray Click to email this to a friend (Opens in new window) Share on Facebook (Opens in new window) Click to share (Opens in new window) Click to share on LinkedIn (Opens in new window) Click to share on Tumblr (Opens in new window) Slow Mo Guys and Cold Spray ) The Slow Mo Guys came to GE Global Research in Niskayuna to film our researchers demonstrate a process called "cold spray", in which metal powders are sprayed at high velocities to build a part or add

  7. Cold Climate Heat Pumps Using Tandem Compressors

    SciTech Connect (OSTI)

    Shen, Bo; Abdelaziz, Omar; Rice, C Keith; Baxter, Van D

    2016-01-01

    In cold climate zones, e.g. ASHRAE climate regions IV and V, conventional electric air-source heat pumps (ASHP) do not work well, due to high compressor discharge temperatures, large pressure ratios and inadequate heating capacities at low ambient temperatures. Consequently, significant use of auxiliary strip heating is required to meet the building heating load. We introduce innovative ASHP technologies as part of continuing efforts to eliminate auxiliary strip heat use and maximize heating COP with acceptable cost-effectiveness and reliability. These innovative ASHP were developed using tandem compressors, which are capable of augmenting heating capacity at low temperatures and maintain superior part-load operation efficiency at moderate temperatures. Two options of tandem compressors were studied; the first employs two identical, single-speed compressors, and the second employs two identical, vapor-injection compressors. The investigations were based on system modeling and laboratory evaluation. Both designs have successfully met the performance criteria. Laboratory evaluation showed that the tandem, single-speed compressor ASHP system is able to achieve heating COP = 4.2 at 47 F (8.3 C), COP = 2.9 at 17 F (-8.3 C), and 76% rated capacity and COP = 1.9 at -13 F (-25 C). This yields a HSPF = 11.0 (per AHRI 210/240). The tandem, vapor-injection ASHP is able to reach heating COP = 4.4 at 47 F, COP = 3.1 at 17 F, and 88% rated capacity and COP = 2.0 at -13 F. This yields a HSPF = 12.0. The system modeling and further laboratory evaluation are presented in the paper.

  8. Cracking a Cold Case and Enduring Mystery | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Call it the ultimate cold case. No crime was committed. But a mystery was waiting to be solved. The critical clues had been buried at sea -- for more than two thousand years. And ...

  9. R-Cold: Proposed Penalty (2013-CE-5354)

    Broader source: Energy.gov [DOE]

    DOE alleged in a Notice of Proposed Civil Penalty that R-Cold, Inc. failed to certify a variety of walk-in cooler or freezer components as compliant with the applicable energy conservation standards.

  10. Cold Vacuum Drying (CVD) Facility Diesel Generator Fire Protection

    SciTech Connect (OSTI)

    SINGH, G.

    2000-04-25

    This Acceptance Test Procedure (ATP) has been prepared to demonstrate that the Fire Protection and Detection System installed by Project W-441 (Cold Vacuum Drying Facility and Diesel Generator Building) functions as required by project specifications.

  11. Slower, colder, longer : prospects for a very cold neutron source.

    SciTech Connect (OSTI)

    Micklich, B. J.; Carpenter, J. M.; Intense Pulsed Neutron Source

    2007-01-01

    The motivation for our study is to establish the prospects for a neutron source providing intense pulsed beams with spectra as cold as is realistic. The scientific motivation is to serve applications in nanoscience, biology and technology.

  12. Cold-Start Performance and Emissions Behavior of Alcohol Fuels...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Engine Using Transient Hardware-In-Loop Test Meth Cold-Start Performance and Emissions Behavior of Alcohol Fuels in an SIDI Engine Using Transient Hardware-In-Loop Test Meth ...

  13. US foreign policy and the CIA: A cold war retrospective

    SciTech Connect (OSTI)

    Not Available

    1994-01-01

    The document consists of three previously announced reports: The CIA under Truman: CIA Cold War Records (PB94-928005); The Cuban Missile Crisis, 1962 (PB92-927906); and Selected Estimates on the Soviet Union (PB93-928112).

  14. Manhattan Project: The Cold War, 1945-1990

    Office of Scientific and Technical Information (OSTI)

    West Berliner talks to the East, Berlin Wall, November 1962 THE COLD WAR (1945-1990) Events > Postscript -- The Nuclear Age, 1945-Present Informing the Public, August 1945 The Manhattan Engineer District, 1945-1946 First Steps toward International Control, 1944-1945 Search for a Policy on International Control, 1945 Negotiating International Control, 1945-1946 Civilian Control of Atomic Energy, 1945-1946 Operation Crossroads, July 1946 The VENONA Intercepts, 1946-1980 The Cold War, 1945-1990

  15. Building America Technology Solutions for New and Existing Homes: Cold

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Climate Foundation Wall Hygrothermal Research Facility (Fact Sheet) | Department of Energy Cold Climate Foundation Wall Hygrothermal Research Facility (Fact Sheet) Building America Technology Solutions for New and Existing Homes: Cold Climate Foundation Wall Hygrothermal Research Facility (Fact Sheet) This case study describes the University of Minnesota's Cloquet Residential Research Facility (CRRF) in northern Minnesota, which features more than 2,500 ft2 of below-grade space for building

  16. Newly Invented Shielding For Stopping Neutrons Cold | Jefferson Lab

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Newly Invented Shielding For Stopping Neutrons Cold Newly Invented Shielding For Stopping Neutrons Cold NEWPORT NEWS, VA, Dec. 9, 2013 - When faced with the challenge of protecting sensitive scientific equipment and computers from radiation, engineers at the U.S. Department of Energy's Thomas Jefferson National Accelerator Facility decided to take matters into their own hands. They came up with three innovative products that could soon find their way to nuclear power plants, particle

  17. Not Too Hot, Not Too Cold - Continuum Magazine | NREL

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Not Too Hot, Not Too Cold Photo by Dennis Schroeder, NREL Not Too Hot, Not Too Cold Thermal management technologies increase vehicle energy efficiency and performance while reducing costs. Mythological character Icarus' melted wings sent him plummeting to earth when he ignored his father's advice and flew too close to the sun. Heat was Icarus' undoing. Today's real-world electric-drive vehicles (EDVs) also require diligent attention to temperature. The battery, power electronic system, electric

  18. Linking Legacies: Connecting the Cold War Nuclear Weapons Production

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Processes to Their Environmental Consequences | Department of Energy Linking Legacies: Connecting the Cold War Nuclear Weapons Production Processes to Their Environmental Consequences Linking Legacies: Connecting the Cold War Nuclear Weapons Production Processes to Their Environmental Consequences This report described each step in the cycle of nuclear weapons production and defined for the first time a planned disposition path for all waste streams generated prior to 1992 as a result of

  19. Lab begins demolition of Cold War-era buildings

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Demolition begins of cold War-Era buildings Lab begins demolition of Cold War-era buildings More than 165,000 square feet of former research, production, and office buildings will be demolished. December 1, 2009 Los Alamos National Laboratory sits on top of a once-remote mesa in northern New Mexico with the Jemez mountains as a backdrop to research and innovation covering multi-disciplines from bioscience, sustainable energy sources, to plasma physics and new materials. Los Alamos National

  20. Cold Climate Building Enclosure Solutions (Technical Report) | SciTech

    Office of Scientific and Technical Information (OSTI)

    Connect Cold Climate Building Enclosure Solutions Citation Details In-Document Search Title: Cold Climate Building Enclosure Solutions This project investigates the energy performance and cost effectiveness of several state-of-the-art retrofit strategies that could be used in triple-deckers and colonial houses, common house types in New England. Several emerging building enclosure technologies were integrated, including high R-value aerogel and vacuum insulations, in forms that would be

  1. Pressure field study of the Tevatron cold compressors

    SciTech Connect (OSTI)

    Klebaner, A.L.; Martinez, A.; Soyars, W.M.; Theilacker, J.C.; /Fermilab

    2003-01-01

    The Fermilab Tevatron cryogenic system utilizes high-speed centrifugal cold compressors, manufactured by Ishikawajima-Harima Heavy Industries Co. Ltd. (IHI), for high-energy operations [1]. The compressor is designed to pump 60 g/sec of 3.6 K saturated helium vapor at a pressure ratio of 2.8, with an off-design range of 40 to 70 g/sec. Operating speeds are between 40 and 95 krpm, with a speed of 80 krpm at the design point. Different heat loads and magnet quench performance of each of the twenty-four satellite refrigerators dictates different process pressure and flow rates of the cold compressors. Reducing the process flow rate can cause the centrifugal cold compressor to stop pumping and subsequently surge. Tests have been conducted at the Cryogenic Test Facility at Fermilab to map the pressure field and appropriate efficiency of the IHI hydrodynamic cold compressor. The information allows tuning of each of the twenty-four Tevatron satellite refrigerators to avoid cold compressor operation near the surge and choke lines. A new impeller has also been tested. The Tevatron cold compressor pressure field and efficiency data with the new impeller are presented in this paper.

  2. Persisting cold extremes under 21st-century warming scenarios

    SciTech Connect (OSTI)

    Kodra, Evan A; Steinhaeuser, Karsten J K; Ganguly, Auroop R

    2011-01-01

    Analyses of climate model simulations and observations reveal that extreme cold events are likely to persist across each land-continent even under 21st-century warming scenarios. The grid-based intensity, duration and frequency of cold extreme events are calculated annually through three indices: the coldest annual consecutive three-day average of daily maximum temperature, the annual maximum of consecutive frost days, and the total number of frost days. Nine global climate models forced with a moderate greenhouse-gas emissions scenario compares the indices over 2091 2100 versus 1991 2000. The credibility of model-simulated cold extremes is evaluated through both bias scores relative to reanalysis data in the past and multi-model agreement in the future. The number of times the value of each annual index in 2091 2100 exceeds the decadal average of the corresponding index in 1991 2000 is counted. The results indicate that intensity and duration of grid-based cold extremes, when viewed as a global total, will often be as severe as current typical conditions in many regions, but the corresponding frequency does not show this persistence. While the models agree on the projected persistence of cold extremes in terms of global counts, regionally, inter-model variability and disparity in model performance tends to dominate. Our findings suggest that, despite a general warming trend, regional preparedness for extreme cold events cannot be compromised even towards the end of the century.

  3. Deterrence, disarmament, and post-cold war stability: Enhancing security for both ``haves`` and ``have nots``

    SciTech Connect (OSTI)

    Lehman, R. F. II

    1995-04-01

    This paper examines possible developments in nuclear disarmament resulting from the end of the Cold War.

  4. Building America Best Practices Series: Volume 3; Builders and Buyers Handbook for Improving New Home Efficiency, Comfort, and Durability in the Cold and Very Cold Climates

    SciTech Connect (OSTI)

    2005-08-01

    The guide book is a resource to help builders large and small build high-quality, energy-efficient homes that achieve 30% energy savings in space conditioning and water heating in the cold and very cold climates.

  5. Prospects for the future development of cold fusion

    SciTech Connect (OSTI)

    Ikegami, H.

    1995-12-01

    Almost five years have passed since the first announcement of cold fusion in March of 1989. Over this period there have been, from time to time, a number of reports of the observation of excess heat and nuclear reactions. Concerning nuclear reactions, there still remains the controversial questions of fusion, which has given its name to the phenomena associated with cold fusion. In any event, so long as the reproducibility remains so poor, it is impossible to resolve such questions and the original controversy has not faded away. From the very beginning of cold fusion, it has been generally conceded among scientists that the claimed excess heat cannot be merely a result of the ordinary DD fusion. Neutron emissions ere extremely weak and sporadic, which made almost nothing of correlation measurements between excess heat and fusion reactions. Another peculiar feature of the nuclear reactions, associated with cold fusion, lies with the observation that the generation of tritium, which is concurrent with neutron emission, is none the less more than ten million times larger than that of the neutrons, and still it is not clear how this relates to the heat. Moreover there are claims that the excess heat production can be correlated to the production of helium-4 as nuclear ashes. These findings have promoted exotic theoretical models to explain cold fusion mechanisms.

  6. COLD WATER VAPOR IN THE BARNARD 5 MOLECULAR CLOUD

    SciTech Connect (OSTI)

    Wirstrm, E. S.; Persson, C. M.; Charnley, S. B.; Cordiner, M. A.; Buckle, J. V.; Takakuwa, S.

    2014-06-20

    After more than 30yr of investigations, the nature of gas-grain interactions at low temperatures remains an unresolved issue in astrochemistry. Water ice is the dominant ice found in cold molecular clouds; however, there is only one region where cold (?10K) water vapor has been detectedL1544. This study aims to shed light on ice desorption mechanisms under cold cloud conditions by expanding the sample. The clumpy distribution of methanol in dark clouds testifies to transient desorption processes at worklikely to also disrupt water ice mantles. Therefore, the Herschel HIFI instrument was used to search for cold water in a small sample of prominent methanol emission peaks. We report detections of the ground-state transition of o-H{sub 2}O (J = 1{sub 10}-1{sub 01}) at 556.9360GHz toward two positions in the cold molecular cloud, Barnard 5. The relative abundances of methanol and water gas support a desorption mechanism which disrupts the outer ice mantle layers, rather than causing complete mantle removal.

  7. Modeling and cold start in alcohol-fueled engines

    SciTech Connect (OSTI)

    Markel, A.J.; Bailey, B.K.

    1998-05-01

    Neat alcohol fuels offer several benefits over conventional gasoline in automotive applications. However, their low vapor pressure and high heat of vaporization make it difficult to produce a flammable vapor composition from a neat alcohol fuel during a start under cold ambient conditions. Various methods have been introduced to compensate for this deficiency. In this study, the authors applied computer modeling and simulation to evaluate the potential of four cold-start technologies for engines fueled by near-neat alcohol. The four technologies were a rich combustor device, a partial oxidation reactor, a catalytic reformer, and an enhanced ignition system. The authors ranked the competing technologies by their ability to meet two primary criteria for cold starting an engine at {minus}25 deg C and also by several secondary parameters related to commercialization. Their analysis results suggest that of the four technologies evaluated, the enhanced ignition system is the best option for further development.

  8. Computer analysis of sodium cold trap design and performance. [LMFBR

    SciTech Connect (OSTI)

    McPheeters, C.C.; Raue, D.J.

    1983-11-01

    Normal steam-side corrosion of steam-generator tubes in Liquid Metal Fast Breeder Reactors (LMFBRs) results in liberation of hydrogen, and most of this hydrogen diffuses through the tubes into the heat-transfer sodium and must be removed by the purification system. Cold traps are normally used to purify sodium, and they operate by cooling the sodium to temperatures near the melting point, where soluble impurities including hydrogen and oxygen precipitate as NaH and Na/sub 2/O, respectively. A computer model was developed to simulate the processes that occur in sodium cold traps. The Model for Analyzing Sodium Cold Traps (MASCOT) simulates any desired configuration of mesh arrangements and dimensions and calculates pressure drops and flow distributions, temperature profiles, impurity concentration profiles, and impurity mass distributions.

  9. Evolution of velocity dispersion along cold collisionless flows

    SciTech Connect (OSTI)

    Banik, Nilanjan; Sikivie, Pierre

    2015-11-17

    We found that the infall of cold dark matter onto a galaxy produces cold collisionless flows and caustics in its halo. If a signal is found in the cavity detector of dark matter axions, the flows will be readily apparent as peaks in the energy spectrum of photons from axion conversion, allowing the densities, velocity vectors and velocity dispersions of the flows to be determined. We also discuss the evolution of velocity dispersion along cold collisionless flows in one and two dimensions. A technique is presented for obtaining the leading behaviour of the velocity dispersion near caustics. The results are used to derive an upper limit on the energy dispersion of the Big Flow from the sharpness of its nearby caustic, and a prediction for the dispersions in its velocity components.

  10. Critical speed measurements in the Tevatron cold compressors

    SciTech Connect (OSTI)

    DeGraff, B.; Bossert, R.; Martinez, A.; Soyars, W.M.; /Fermilab

    2006-01-01

    The Fermilab Tevatron cryogenic system utilizes high-speed centrifugal cold compressors, manufactured by Ishikawajima-Harima Heavy Industries Co. Ltd. (IHI), for high energy operations. Nominal operating range for these compressors is 43,000 to 85,000 rpm. Past foil bearing failures prompted investigation to determine if critical speeds for operating compressors fall within operating range. Data acquisition hardware and software settings will be discussed for measuring liftoff, first critical and second critical speeds. Several tests provided comparisons between an optical displacement probe and accelerometer measurements. Vibration data and analysis of the 20 Tevatron ring cold compressors will be presented.

  11. Semiautomatic cold wire feeder systems increase GTA productivity

    SciTech Connect (OSTI)

    Richardson, M. )

    1995-01-01

    Often, the focus of attempts to increase GTA welding productivity is on studies to determine if justification exists for additional workstations, or for the investment in new fully automated dedicated welding fixtures. Often less costly and simpler solutions can bring about the necessary means to increase production rates and reduce operating costs. For short-run production applications, it is almost impossible to justify the substantial investment in a dedicated automatic fixture. Now, low cost GTA cold wire feeder systems are within the reach of even small shops. The paper views how cold wire equipment has been applied in several GTAW applications to improve results.

  12. Note: High density pulsed molecular beam for cold ion chemistry

    SciTech Connect (OSTI)

    Kokish, M. G.; Rajagopal, V.; Marler, J. P.; Odom, B. C.

    2014-08-15

    A recent expansion of cold and ultracold molecule applications has led to renewed focus on molecular species preparation under ultrahigh vacuum conditions. Meanwhile, molecular beams have been used to study gas phase chemical reactions for decades. In this paper, we describe an apparatus that uses pulsed molecular beam technology to achieve high local gas densities, leading to faster reaction rates with cold trapped ions. We characterize the beam's spatial profile using the trapped ions themselves. This apparatus could be used for preparation of molecular species by reactions requiring excitation of trapped ion precursors to states with short lifetimes or for obtaining a high reaction rate with minimal increase of background chamber pressure.

  13. Cold fusion experiments with ordinary water and thin nickel foil

    SciTech Connect (OSTI)

    Matsumoto, Takaaki )

    1993-11-01

    Cold fusion experiments with ordinary water and thin nickel foils are described. The temperature variation and the surface condition of the foils are examined. It has been proven that ordinary water can produce excess heat. Furthermore, reaction products are recorded on nuclear emulsions. Charged particles, electrons, protons, and deuterons, are observed. Micro-explosions caused by gravity decay of neutron nuclei are also recorded. Many traces indicating tiny black holes and white holes are clearly observed. The mechanisms of cold fusion with ordinary water are discussed in terms of the Nattoh model. 17 refs., 9 figs.

  14. Search for neutrons as evidence of cold fusion

    SciTech Connect (OSTI)

    Cannizzaro, F.; Greco, G.; Raneli, M.; Spitale, M.C.; Tomarchio, E. )

    1992-01-01

    In this paper investigations performed at the University of Palermo in an attempt to reproduce the cold fusion experiment are reported. The search was devoted to detecting neutron emission from palladium electrodes electrolytically charged with deuterium. In no test was neutron emission significantly over the background observed, either in bursts or continuous. Results of a few tests are reported. For the more sensitive test, an upper limit for D(d,n) cold fusion (at 98% confidence level) of {lambda}{sub f} {lt} 3.6 {times} 10{sup {minus}24} fusion/s {center dot} d-d pair is determined.

  15. Recovery Act funds advance cleanup efforts at Cold War site

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Cleanup efforts at Cold War site Recovery Act funds advance cleanup efforts at Cold War site A local small business, ARSEC Environmental, LLC, of White Rock, NM, won a $2 million task order in April to perform this work. June 29, 2010 Los Alamos National Laboratory sits on top of a once-remote mesa in northern New Mexico with the Jemez mountains as a backdrop to research and innovation covering multi-disciplines from bioscience, sustainable energy sources, to plasma physics and new materials.

  16. Expansion of a cold non-neutral plasma slab

    SciTech Connect (OSTI)

    Karimov, A. R.; Yu, M. Y.; Stenflo, L.

    2014-12-15

    Expansion of the ion and electron fronts of a cold non-neutral plasma slab with a quasi-neutral core bounded by layers containing only ions is investigated analytically and exact solutions are obtained. It is found that on average, the plasma expansion time scales linearly with the initial inverse ion plasma frequency as well as the degree of charge imbalance, and no expansion occurs if the cold plasma slab is stationary and overall neutral. However, in both cases, there can exist prominent oscillations on the electron front.

  17. Mr. Frank Archer President Niagara Cold Drawn Steel Corporation

    Office of Legacy Management (LM)

    Department of Energy Washington, DC 20585 FEB 2 1 1991 ' i-. 1,; ' -, f ' + \ 1 : , .J p- * c - Mr. Frank Archer President Niagara Cold Drawn Steel Corporation 110 Hopkins Street P.O. Box 399 Buffalo, NY 14240 Dear Mr. Archer: I have executed the consent forms for the performance of a radiological survey of the Niagara Cold Drawn Steel Corporation's property under the Formerly Utilized Sites Remedial Action Program (FUSRAP) of the U.S. Department of Energy (DOE). I enclose a copy of the consent

  18. THE COLD AND DARK PROCESS AT THE SAVANNAH RIVER SITE

    SciTech Connect (OSTI)

    Gilmour, J; William Austin, W; Cathy Sizemore, C

    2007-01-31

    The deactivation and decommissioning (D&D) of a facility exposes D&D workers to numerous hazards. One of the more serious hazards is coming into contact to hazardous energy sources (e.g. electrical, pressurized steam). At the Savannah River Site (SRS) a formal process for identifying and eliminating sources of hazardous energy was developed and is called ''Cold & Dark''. Several ''near miss'' events involving cutting of energized conductors during D&D work in buildings thought to be isolated identified the need to have a formal process to identify and isolate these potentially hazardous systems. This process was developed using lessons learned from D&D activities at the Rocky Flats Environmental Technology Site (Rocky Flats) in Colorado. The Cold & Dark process defines an isolation boundary (usually a building perimeter) and then systematically identifies all of the penetrations through this boundary. All penetrations that involve hazardous energy sources are then physically air-gapped. The final product is a documented declaration of isolation performed by a team involving operations, engineering, and project management. Once the Cold & Dark declaration is made for a building work can proceed without the usual controls used in an operational facility (e.g. lockout/tagout, arc flash PPE). It is important to note that the Cold & Dark process does not remove all hazards from a facility. Work planning and controls still need to address hazards that can be present from such things as chemicals, radiological contamination, residual liquids, etc., as well as standard industrial hazards.

  19. Cold Test Operation of the German VEK Vitrification Plant

    SciTech Connect (OSTI)

    Fleisch, J.; Schwaab, E.; Weishaupt, M. [WAK GmbH, Eggenstein-Leopoldshafen (Germany); Gruenewald, W.; Roth, G.; Tobie, W. [Forschungszentrum Karlsruhe, Institut fur Nukleare Entsorgung, Eggenstein-Leopoldshafen (Germany)

    2008-07-01

    In 2007 the German High-Level Liquid Waste (HLLW) Vitrification plant VEK (Verglasungseinrichtung Karlsruhe) has passed a three months integral cold test operation as final step before entering the hot phase. The overall performance of the vitrification process equipment with a liquid-fed ceramic glass melter as main component proved to be completely in line with the requirements of the regulatory body. The retention efficiency of main radioactive-bearing elements across melter and wet off-gas treatment system exceeded the design values distinctly. The strategy to produce a specified waste glass could be successfully demonstrated. The results of the cold test operation allow entering the next step of hot commissioning, i.e. processing of approximately 2 m{sup 3} of diluted HLLW. In summary: An important step of the VEK vitrification plant towards hot operation has been the performance of the cold test operation from April to July 2007. This first integral operation was carried out under boundary conditions and rules established for radioactive operation. Operation and process control were carried out following the procedure as documented in the licensed operational manuals. The function of the process technology and the safe operation could be demonstrated. No severe problems were encountered. Based on the positive results of the cold test, application of the license for hot operation has been initiated and is expected in the near future. (authors)

  20. Fire Hazard Analysis for the Cold Vacuum Drying (CVD) Facility

    SciTech Connect (OSTI)

    JOHNSON, B.H.

    1999-08-19

    This Fire Hazard Analysis assesses the risk from fire within individual fire areas in the Cold Vacuum Drying Facility at the Hanford Site in relation to existing or proposed fire protection features to ascertain whether the objectives of DOE Order 5480.7A Fire Protection are met.

  1. Cold Vacuum Drying (CVD) Facility Design Basis Accident Analysis Documentation

    SciTech Connect (OSTI)

    PIEPHO, M.G.

    1999-10-20

    This document provides the detailed accident analysis to support HNF-3553, Annex B, Spent Nuclear Fuel Project Final Safety Analysis Report, ''Cold Vacuum Drying Facility Final Safety Analysis Report (FSAR).'' All assumptions, parameters and models used to provide the analysis of the design basis accidents are documented to support the conclusions in the FSAR.

  2. Transfer-type products accompanying cold fusion reactions

    SciTech Connect (OSTI)

    Adamian, G.G.; Antonenko, N.V.

    2005-12-15

    Production of nuclei heavier than the target is treated for projectile-target combinations used in cold fusion reactions leading to superheavy nuclei. These products are related to transfer-type or to asymmetry-exit-channel quasifission reactions. The production of isotopes in the transfer-type reactions emitting of {alpha} particles with large energies is discussed.

  3. Review of experimental observations about the cold fusion effect

    SciTech Connect (OSTI)

    Storms, E. )

    1991-12-01

    In this paper the experimental literature describing the cold fusion phenomenon is reviewed. The number and variety of careful experimental measurements of heat, tritium, neutron, and helium production strongly support the occurrence of nuclear reactions in a metal lattice near room temperature as proposed by Pons and Fleischmann and independently by Jones.

  4. Prediction of new particle emission on cold fusion

    SciTech Connect (OSTI)

    Matsumoto, T. . Dept. of Nuclear Engineering)

    1990-12-01

    In this paper the energy distribution of cold fusion products is analyzed based on the Nattoh model. A new hydrogen-catalyzed fusion reaction is proposed to occur in a metal. From the differences in the Q value and other parameters, a new particles, the iton, is predicted to be emitted, with a rest mass 2 to 26 times that of an electron.

  5. Can binuclear atoms solve the cold fusion puzzle

    SciTech Connect (OSTI)

    Cerofolini, G.F. ); Para, A.F. )

    1993-01-01

    The internal and external inconsistencies of cold fusion phenomena are discussed. It is shown that most of these inconsistencies can be removed by assuming the formation of binuclear atoms that have the ability to trap thermal neutrons from the natural background in a localized state. 29 refs., 3 figs.

  6. Some theories of cold nuclear fusion; A review

    SciTech Connect (OSTI)

    Preparata, G. )

    1991-08-01

    In this paper a review is presented of the main theoretical attempts to describe the phenomenology of cold fusion, whose general structure begins to clearly unravel. The main conclusion is that the approaches that are likely to be of relevance must invoke processes where the elementary components (nuclei and electrons) of condensed matter act in a coherent fashion.

  7. Data Collection for Improved Cold Temperature Thermal Modeling | Department

    Broader source: Energy.gov (indexed) [DOE]

    of Energy 2 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting PDF icon vss088_jehlik_2012_p.pdf More Documents & Publications Data Collection for Improved Cold Temperature Thermal Modeling and Strategy Development Advanced Technology Vehicle Lab Benchmarking - Level 2 (in-depth)

  8. The Cold and Dark Process at the Savannah River Site

    SciTech Connect (OSTI)

    Gilmour, John C.; Willis, Michael L.

    2008-01-15

    The deactivation and decommissioning (D and D) of a facility exposes D and D workers to numerous hazards. One of the more serious hazards is coming into contact to hazardous energy sources (e.g. electrical, pressurized steam). At the Savannah River Site (SRS) a formal process for identifying and eliminating sources of hazardous energy was developed and is called 'Cold and Dark'. Several 'near miss' events involving cutting of energized conductors during D and D work in buildings thought to be isolated identified the need to have a formal process to identify and isolate these potentially hazardous systems. This process was developed using lessons learned from D and D activities at the Rocky Flats Environmental Technology Site (Rocky Flats) in Colorado. The Cold and Dark process defines an isolation boundary (usually a building perimeter) and then systematically identifies all of the penetrations through this boundary. All penetrations that involve hazardous energy sources are then physically air-gapped. The final product is a documented declaration of isolation performed by a team involving operations, engineering, and project management. Once the Cold and Dark declaration is made for a building work can proceed without the usual controls used in an operational facility (e.g. lockout/tag-out, arc flash PPE). It is important to note that the Cold and Dark process does not remove all hazards from a facility. Work planning and controls still need to address hazards that can be present from such things as chemicals, radiological contamination, residual liquids, etc., as well as standard industrial hazards. Savannah River Site experienced 6 electrical events prior to declaring a facility 'cold and dark' and has had zero electrical events after 'cold and dark' declaration (263 facilities to date). The formal Cold and Dark process developed at SRS has eliminated D and D worker exposures to hazardous energy sources. Since the implementation of the process there have been no incidents involving energized conductors or pressurized liquids/gases. During this time SRS has demolished over 200 facilities. The ability to perform intrusive D and D activities without the normal controls such as lock outs results in shorter schedule durations and lower overall costs for a facility D and D.

  9. V-045: Adobe ColdFusion Lets Local Users Bypass Sandbox Restrictions...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    5: Adobe ColdFusion Lets Local Users Bypass Sandbox Restrictions V-045: Adobe ColdFusion Lets Local Users Bypass Sandbox Restrictions December 12, 2012 - 2:00am Addthis PROBLEM:...

  10. U-257: Adobe ColdFusion Unspecified Bug Lets Remote Users Deny...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    7: Adobe ColdFusion Unspecified Bug Lets Remote Users Deny Service U-257: Adobe ColdFusion Unspecified Bug Lets Remote Users Deny Service September 12, 2012 - 6:00am Addthis...

  11. Vessel Cold-Ironing Using a Barge Mounted PEM Fuel Cell: Project...

    Energy Savers [EERE]

    Vessel Cold-Ironing Using a Barge Mounted PEM Fuel Cell: Project Scoping and Feasibility Vessel Cold-Ironing Using a Barge Mounted PEM Fuel Cell: Project Scoping and Feasibility ...

  12. Independent Oversight Review, Hanford K Basin and Cold Vacuum Drying Facility- August 2012

    Broader source: Energy.gov [DOE]

    Review of Hanford K Basin and Cold Vacuum Drying Facility Found Fuel Multi-Canister Overpack Operations

  13. Formation of superheavy nuclei in cold fusion reactions

    SciTech Connect (OSTI)

    Feng Zhaoqing; Jin Genming; Li Junqing; Scheid, Werner

    2007-10-15

    Within the concept of the dinuclear system (DNS), a dynamical model is proposed for describing the formation of superheavy nuclei in complete fusion reactions by incorporating the coupling of the relative motion to the nucleon transfer process. The capture of two heavy colliding nuclei, the formation of the compound nucleus, and the de-excitation process are calculated by using an empirical coupled channel model, solving a master equation numerically and applying statistical theory, respectively. Evaporation residue excitation functions in cold fusion reactions are investigated systematically and compared with available experimental data. Maximal production cross sections of superheavy nuclei in cold fusion reactions with stable neutron-rich projectiles are obtained. Isotopic trends in the production of the superheavy elements Z=110, 112, 114, 116, 118, and 120 are analyzed systematically. Optimal combinations and the corresponding excitation energies are proposed.

  14. Observation of meshlike traces on nuclear emulsions during cold fusion

    SciTech Connect (OSTI)

    Matsumoto, Takaaki )

    1993-01-01

    Cold fusion products from the electrolysis of heavy water have been directly measured by using a thin palladium foil. Several anomalous traces have been clearly recorded on nuclear emulsions. Some traces have meshlike structures, which are classified into two types: (a) ones associated with ring traces that are caused by the gravity decay of quad-neutrons and (b) ones with no ring traces. The mechanisms that form these meshlike traces are discussed in terms of the Nattoh model. It is inferred that multiple-neutron nuclei such as quad-neutrons, covered by itonic mesh and iton beads, are born during cold fusion. Furthermore, other anomalous traces suggest the production of a new heavy particle during gravity decay. 14 refs., 10 figs.

  15. SAVANNAH RIVER SITE COLD WAR HISTORIC PROPERTY DOCUMENTATION

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    WAR HISTORIC PROPERTY DOCUMENTATION NARRATIVE AND PHOTOGRAPHY CMX AND TNX SAVANNAH RIVER'S PILOT PLANTS Aiken County, South Carolina SAVANNAH RIVER SITE COLD WAR HISTORIC PROPERTY DOCUMENTATION CMX AND TNX CMX AND TNX SA SA V V ANNAH RIVER'S ANNAH RIVER'S PILOT PLANTS PILOT PLANTS Aiken County, South Carolina NARRATIVE AND PHOTOGRAPHY ii ABSTRACT This documentation was prepared in accordance with a Memorandum of Agreement (MOA) signed by the Department of Energy-Savannah River (DOE-SR) and the

  16. Reproducible cold fusion reaction using a complex cathode

    SciTech Connect (OSTI)

    Arata, Y.; Zhang, Y.C. )

    1992-09-01

    This paper discusses a new complex cathode which was developed, consisting of a nickel (or palladium) rod with a palladium layer applied by plasma spraying. High reproducibility of a cold fusion reaction is confirmed by using this cathode. The palladium layer activates the surface functions of the deuterated cathode, and reliable evidence is obtained that a new type of heat generation occurred in the complex cathode.

  17. U-060: Security update: Hotfix available for ColdFusion

    Broader source: Energy.gov [DOE]

    Vulnerabilities have been identified in ColdFusion 9.0.1 and earlier versions for Windows, Macintosh and UNIX. These vulnerabilities could lead to a cross-site scripting attack. Adobe categorizes this as an important update and recommends that users apply the latest update for their product installation.This update resolves a cross-site scripting vulnerability in cfform tag (CVE-2011-2463). This update resolves a cross-site scripting vulnerability in RDS (CVE-2011-4368).

  18. Viscoelastic modes in a strongly coupled, cold, magnetized dusty plasma

    SciTech Connect (OSTI)

    Banerjee, Debabrata; Mylavarapu, Janaki Sita; Chakrabarti, Nikhil

    2010-11-15

    A generalized hydrodynamical model has been used to study the low frequency modes in a strongly coupled, cold, magnetized dusty plasma. Such plasmas exhibit elastic properties due to the strong correlations among dust particles and the tensile stresses imparted by the magnetic field. It has been shown that longitudinal compressional Alfven modes and elasticity modified transverse shear mode exist in such a medium. The features of these collective modes are established and discussed.

  19. Quantum Theory for Cold Avalanche Ionization in Solids

    SciTech Connect (OSTI)

    Deng, H. X.; Zu, X. T.; Xiang, X.; Sun, K.

    2010-09-10

    A theory of photon-assisted impact ionization in solids is presented. Our theory makes a quantum description of the new impact ionization--cold avalanche ionization recently reported by P. P. Rajeev, M. Gertsvolf, P. B. Corkum, and D. M. Rayner [Phys. Rev. Lett. 102, 083001 (2009)]. The present theory agrees with the experiments and can be reduced to the traditional impact ionization expression in the absence of a laser.

  20. Cold Vacuum Drying (CVD) Facility Hazards Analysis Report

    SciTech Connect (OSTI)

    CROWE, R.D.

    2000-08-07

    This report describes the methodology used in conducting the Cold Vacuum Drying Facility (CVDF) Hazard Analysis to support the CVDF Final Safety Analysis Report and documents the results. The hazard analysis was performed in accordance with DOE-STD-3009-94, ''Preparation Guide for US. Department of Energy Nonreactor Nuclear Facility Safety Analysis Reports,'' and implements the requirements of DOE Order 5480.23, ''Nuclear Safety Analysis Reports.''

  1. Searching for WISPy cold dark matter with a dish antenna

    SciTech Connect (OSTI)

    Horns, Dieter; Jaeckel, Joerg; Lindner, Axel; Ringwald, Andreas; Lobanov, Andrei; Redondo, Javier E-mail: jjaeckel@thphys.uni-heidelberg.de E-mail: alobanov@mpifr-bonn.mpg.de E-mail: andreas.ringwald@desy.de

    2013-04-01

    The cold dark matter of the Universe may be comprised of very light and very weakly interacting particles, so-called WISPs. Two prominent examples are hidden photons and axion-like particles. In this note we propose a new technique to sensitively search for this type of dark matter with dish antennas. The technique is broadband and allows to explore a whole range of masses in a single measurement.

  2. Cold Vacuum Drying facility design basis accident analysis documentation

    SciTech Connect (OSTI)

    CROWE, R.D.

    2000-08-08

    This document provides the detailed accident analysis to support HNF-3553, Annex B, Spent Nuclear Fuel Project Final Safety Analysis Report (FSAR), ''Cold Vacuum Drying Facility Final Safety Analysis Report.'' All assumptions, parameters, and models used to provide the analysis of the design basis accidents are documented to support the conclusions in the FSAR. The calculations in this document address the design basis accidents (DBAs) selected for analysis in HNF-3553, ''Spent Nuclear Fuel Project Final Safety Analysis Report'', Annex B, ''Cold Vacuum Drying Facility Final Safety Analysis Report.'' The objective is to determine the quantity of radioactive particulate available for release at any point during processing at the Cold Vacuum Drying Facility (CVDF) and to use that quantity to determine the amount of radioactive material released during the DBAs. The radioactive material released is used to determine dose consequences to receptors at four locations, and the dose consequences are compared with the appropriate evaluation guidelines and release limits to ascertain the need for preventive and mitigative controls.

  3. Surge recovery techniques for the Tevatron cold compressors

    SciTech Connect (OSTI)

    Martinez, A.; Klebaner, A.L.; Makara, J.N.; Theilacker, J.C.; /Fermilab

    2006-01-01

    The Fermilab Tevatron cryogenic system utilizes high-speed centrifugal cold compressors, made by Ishikawajima-Harima Heavy Industries Co. Ltd. (IHI), for high-energy operations [1]. The compressor is designed to pump 60 g/s of 3.6 K saturated helium vapor at a pressure ratio of 2.8, with an off-design range of 40 to 70 g/s and operating speeds between 40 and 95 krpm. Since initial commissioning in 1993, Tevatron transient conditions such as quench recovery have led to multiple-location machine trips as a result of the cold compressors entering the surge regime. Historically, compressors operating at lower inlet pressures and higher speeds have been especially susceptible to these machine trips and it was not uncommon to have multiple compressor trips during large multiple-house quenches. In order to cope with these events and limit accelerator down time, surge recovery techniques have been implemented in an attempt to prevent the compressors from tripping once the machine entered this surge regime. This paper discusses the different methods of surge recovery that have been employed. Data from tests performed at the Cryogenic Test Facility at Fermilab as well as actual Tevatron operational data were utilized. In order to aid in the determination of the surge region, a full mapping study was undertaken to characterize the entire pressure field of the cold compressor. These techniques were then implemented and tested at several locations in the Tevatron with some success.

  4. Cold bond agglomeration of waste oxides for recycling

    SciTech Connect (OSTI)

    D`Alessio, G.; Lu, W.K.

    1996-12-31

    Recycling of waste oxides has been an on-going challenge for integrated steel plants. The majority of these waste oxides are collected from the cleaning systems of ironmaking and steelmaking processes, and are usually in the form of fine particulates and slurries. In most cases, these waste materials are contaminated by oils and heavy metals and often require treatment at a considerable expense prior to landfill disposal. This contamination also limits the re-use or recycling potential of these oxides as secondary resources of reliable quality. However, recycling of some selected wastes in blast furnaces or steelmaking vessels is possible, but first requires agglomeration of the fine particulate by such methods as cold bond briquetting. Cold bond briquetting technology provides both mechanical compacting and bonding (with appropriate binders) of the particulates. This method of recycling has the potential to be economically viable and environmentally sustainable. The nature of the present study is cold bond briquetting of iron ore pellet fines with a molasses-cement-H{sub 2}O binder for recycling in a blast furnace. The inclusion of molasses is for its contribution to the green strength of briquettes. During the curing stage, significant gains in strength may be credited to molasses in the presence of cement. The interactions of cement (and its substitutes), water and molasses and their effects on the properties of the agglomerates during and after various curing conditions were investigated. Tensile strengths of briquettes made in the laboratory and subjected to experimental conditions which simulated the top part of a blast furnace shaft were also examined.

  5. Reducing cold-start emissions by catalytic converter thermal management

    SciTech Connect (OSTI)

    Burch, S D; Potter, T F; Keyser, M A; Brady, M J; Michaels, K F

    1995-01-01

    Vacuum insulation and phase-change thermal storage have been used to enhance the heat retention of a prototype catalytic converter. Storing heat in the converter between trips allows exhaust gases to be converted more quickly, significantly reducing cold-start emissions. Using a small metal hydride, the thermal conductance of the vacuum insulation can be varied continuously between 0.49 and 27 W/m{sup 2}K (R-12 to R-0.2 insulation) to prevent overheating of the catalyst. A prototype was installed in a Dodge Neon with a 2.0-liter engine. Following a standard preconditioning and a 23-hour cold soak, an FTP (Federal Test Procedure) emissions test was performed. Although exhaust temperatures during the preconditioning were not hot enough to melt the phase-change material, the vacuum insulation performed well, resulting in a converter temperature of 146{degrees}C after the 23-hour cold soak at 27{degrees}C. Compared to the same converter at ambient conditions, overall emissions of CO and HC were reduced by 52 % and 29 %, to 0.27 and 0.037 g/mile, respectively. The maximum converter temperature during the FTP cycle was 720{degrees}C. This limited testing was performed with a nearly-fresh palladium-only catalyst, but demonstrates the potential of this vacuum insulation approach for emissions reduction and thermal control. Further testing is ongoing. An initial assessment of several production issues is made, including high-volume fabrication challenges, durability, and cost.

  6. The Effect of Cold Work on Properties of Alloy 617

    SciTech Connect (OSTI)

    Richard Wright

    2014-08-01

    Alloy 617 is approved for non-nuclear construction in the ASME Boiler and Pressure Vessel Code Section I and Section VIII, but is not currently qualified for nuclear use in ASME Code Section III. A draft Code Case was submitted in 1992 to qualify the alloy for nuclear service but efforts were stopped before the approval process was completed.1 Renewed interest in high temperature nuclear reactors has resulted in a new effort to qualify Alloy 617 for use in nuclear pressure vessels. The mechanical and physical properties of Alloy 617 were extensively characterized for the VHTR programs in the 1980’s and incorporated into the 1992 draft Code Case. Recently, the properties of modern heats of the alloy that incorporate an additional processing step, electro-slag re-melting, have been characterized both to confirm that the properties of contemporary material are consistent with those in the historical record and to increase the available database. A number of potential issues that were identified as requiring further consideration prior to the withdrawal of the 1992 Code Case are also being re-examined in the current R&D program. Code Cases are again being developed to allow use of Alloy 617 for nuclear design within the rules of the ASME Boiler and Pressure Vessel Code. In general the Code defines two temperature ranges for nuclear design with austenitic and nickel based alloys. Below 427°C (800°F) time dependent behavior is not considered, while above this temperature creep and creep-fatigue are considered to be the dominant life-limiting deformation modes. There is a corresponding differentiation in the treatment of the potential for effects associated with cold work. Below 427°C the principal issue is the relationship between the level of cold work and the propensity for stress corrosion cracking and above that temperature the primary concern is the impact of cold work on creep-rupture behavior.

  7. Miniature quadrupole mass spectrometer having a cold cathode ionization source

    DOE Patents [OSTI]

    Felter, Thomas E.

    2002-01-01

    An improved quadrupole mass spectrometer is described. The improvement lies in the substitution of the conventional hot filament electron source with a cold cathode field emitter array which in turn allows operating a small QMS at much high internal pressures then are currently achievable. By eliminating of the hot filament such problems as thermally "cracking" delicate analyte molecules, outgassing a "hot" filament, high power requirements, filament contamination by outgas species, and spurious em fields are avoid all together. In addition, the ability of produce FEAs using well-known and well developed photolithographic techniques, permits building a QMS having multiple redundancies of the ionization source at very low additional cost.

  8. Deuterium concentration and cold fusion; Rate distributions in palladium

    SciTech Connect (OSTI)

    Rogers, V.C.; Sandquist, G.M.; Nielson, K.K. )

    1989-12-01

    Cold fusion reactions and excess heat production have been reported in the electrolysis of heavy water with a palladium metal cathode. Solution of the standard diffusion equation for deuterium without fusion indicates that the deuterium concentration distribution rapidly becomes constant in the palladium lattice. Solution of the nonlinear diffusion equation for deuterium undergoing fusion also gives constant deuterium concentrations, suggesting that any fusion occurs uniformly throughout the palladium lattice. The hypothesis that fusion reactions occur predominantly at the palladium surface is shown to be inconsistent with experimental data.

  9. Thermal, thermoelectric, and cathode poisoning effects in cold fusion experiments

    SciTech Connect (OSTI)

    Keesing, R.G.; Greenhow, R.C.; Cohler, M.D. ); McQuillan, A.J. )

    1991-03-01

    This paper reports on an unsuccessful attempt to repeat the observations by Fleischmann and Pons of cold nuclear fusion in deuterium-charged palladium; no excess heat is found, nor is any gamma or neutron activity identified. Peltier heating at the palladium/platinum junction is investigated, but no effects are seen; the possibility remains, however, that a large Peltier coefficient may arise for deuterium concentrations that render the palladium-deuterium semiconducting. Finally, the effects of poisoning the palladium with cyanide were investigated.

  10. Evaluation of the intermittent GTA cold wire feed weld system

    SciTech Connect (OSTI)

    Dereskiewicz, J.P.

    1991-08-01

    An intermittent gas tungsten arc cold wire feed process was statistically evaluated to determine the feasibility of applying this process to meet the 0.030-inch weld penetration and peak temperature requirements when unfavorable joint tolerances exist on a subassembly weld. The wire feed system was determined to only slightly benefit the welding process over normal pulsed gas tungsten arc welding using traditional wire feeding capabilities. However, the complexity of this process and extensive welding operator training and qualification does not outweigh the benefits of incorporating this synchronized pulse wire feed system in production. 2 refs., 43 figs., 11 tabs.

  11. Condensate fraction of cold gases in a nonuniform external potential

    SciTech Connect (OSTI)

    Astrakharchik, G. E.; Krutitsky, K. V.

    2011-09-15

    Exact calculation of the condensate fraction in multidimensional inhomogeneous interacting Bose systems in a confining potential of arbitrary shape is a difficult computational problem. We have developed an iterative procedure which allows us to calculate the condensate fraction as well as the corresponding eigenfunction of the one-body density matrix. We successfully validate this procedure in diffusion Monte Carlo simulations of a Bose gas in an optical lattice at zero temperature. We also discuss the relation between different criteria used for testing coherence in cold Bose systems, such as the fraction of particles that are superfluid, condensed, or in the zero-momentum state.

  12. The Cold Dark Matter Search test stand warm electronics card

    SciTech Connect (OSTI)

    Hines, Bruce; Hansen, Sten; Huber, Martin; Kiper, Terry; Rau, Wolfgang; Saab, Tarek; Seitz, Dennis; Sundqvist, Kyle; Mandic, Vuk; /Minnesota U.

    2010-11-01

    A card which does the signal processing for four SQUID amplifiers and two charge sensitive channels is described. The card performs the same functions as is presently done with two custom 9U x 280mm Eurocard modules, a commercial multi-channel VME digitizer, a PCI to GPIB interface, a PCI to VME interface and a custom built linear power supply. By integrating these functions onto a single card and using the power over Ethernet standard, the infrastructure requirements for instrumenting a Cold Dark Matter Search (CDMS) detector test stand are significantly reduced.

  13. Nonlinear lower hybrid oscillations in a cold viscous plasma

    SciTech Connect (OSTI)

    Maity, Chandan; Chakrabarti, Nikhil

    2011-12-15

    An analytical description of nonlinear lower hybrid oscillations in a cold quasi-neutral plasma in the presence of viscosity is presented in one spatial dimension by using Lagrangian variables. By treating viscosity coefficients of the electron and ion fluids as inversely proportional to their respective densities, an exact solution is obtained. It is found that the damping rate of such oscillations is directly proportional to the effective viscosity coefficients of electron and ion fluids. A possible implication of such solutions is briefly outlined.

  14. ELECTRICAL CIRCUITS USING COLD-CATHODE TRIODE VALVES

    DOE Patents [OSTI]

    Goulding, F.S.

    1957-11-26

    An electrical circuit which may be utilized as a pulse generator or voltage stabilizer is presented. The circuit employs a cold-cathode triode valve arranged to oscillate between its on and off stages by the use of selected resistance-capacitance time constant components in the plate and trigger grid circuits. The magnitude of the d-c voltage applied to the trigger grid circuit effectively controls the repetition rate of the output pulses. In the voltage stabilizer arrangement the d-c control voltage is a portion of the supply voltage and the rectified output voltage is substantially constant.

  15. Materials Selection for the HFIR Cold Neutron Source

    SciTech Connect (OSTI)

    Farrell, K.

    2001-08-24

    In year 2002 the High Flux Isotope Reactor (HFIR) will be fitted with a source of cold neutrons to upgrade and expand its existing neutron scattering facilities. The in-reactor components of the new source consist of a moderator vessel containing supercritical hydrogen gas moderator at a temperature of 20K and pressure of 15 bar, and a surrounding vacuum vessel. They will be installed in an enlarged beam tube located at the site of the present horizontal beam tube, HB-4; which terminates within the reactor's beryllium reflector. These components must withstand exceptional service conditions. This report describes the reasons and factors underlying the choice of 6061-T6 aluminum alloy for construction of the in-reactor components. The overwhelming considerations are the need to minimize generation of nuclear heat and to remove that heat through the flowing moderator, and to achieve a minimum service life of about 8 years coincident with the replacement schedule for the beryllium reflector. 6061-T6 aluminum alloy offers the best combination of low nuclear heating, high thermal conductivity, good fabricability, compatibility with hydrogen, superior cryogenic properties, and a well-established history of satisfactory performance in nuclear environments. These features are documented herein. An assessment is given of the expected performance of each component of the cold source.

  16. A survey of current international ``cold fusion`` research

    SciTech Connect (OSTI)

    Fox, H.; Bailey, P.

    1995-12-31

    A new energy producing technology has been found in several so-called ``cold fusion`` experiments. In years past, these effects have been difficult to reproduce, but are now being replicated internationally. Energy production has been achieved in reactors using heavy water (D{sub 2}O) and palladium cathodes. Excess energy has also been produced using light water (H{sub 2}O) and nickel cathodes. Significant results have been reported by SRI, International at the 1994 IECEC. In several types of experimental reactors, more thermal energy is produced than input by electrical energy. This ``excess heat`` has now been replicated in 30 countries and significant amounts of nuclear by-products have also been measured. Whether all of the observed excess thermal heat is the result of nuclear reactions is still being investigated. A key to the process is the purity and quality of the cathode metals used. In addition, some of the reactors are strongly sensitive to hydrogen or deuterium loading. Many papers have now been published reporting on excess thermal heat and on some nuclear by-products. This paper summarizes the results of six years of collecting and reviewing over 2,000 technical papers on cold fusion. Successful experimental papers are tabulated by country and year. Continuing experimental efforts are cited and the various types of experimental evidence are reviewed.

  17. A REALISTIC EXAMINATION OF COLD FUSION CLAIMS 24 YEARS LATER

    SciTech Connect (OSTI)

    Shanahan, K.

    2012-10-22

    On March 29, 1989, chemists Martin Fleischmann and Stanley Pons announced they had discovered an effect whose explanation was required to lie in the realm of nuclear reactions. Their claim, and those subsequent to it of roughly similar nature, became known as ‘cold fusion’. Research continues to this day on this effect, but what has become clear is that whatever it is, it is not a conventional fusion process. Thus the ‘cold fusion’ moniker is somewhat inappropriate and many current researchers in the field prefer the term “Low Energy Nuclear Reactions (LENR)”, although other terms have been coined for it as well. the results developed out of the LENR research do in fact show something is happening to produce signals which might be interpreted as supporting nuclear reactions (which is what encourages and sustains LENR researchers), but which can also be interpreted via a set of unique and interesting conventional processes. The focus of this document is to describe and address recent objections to such processes so that subsequent LENR research can be guided to develop information that will determine whether either set of explanations has merit. It is hoped that criteria delineated herein will aid the USDOE and other agencies in determining if LENR proposals are meritorious and worthy of support or not.

  18. Human factors engineering report for the cold vacuum drying facility

    SciTech Connect (OSTI)

    IMKER, F.W.

    1999-06-30

    The purpose of this report is to present the results and findings of the final Human Factors Engineering (HFE) technical analysis and evaluation of the Cold Vacuum Drying Facility (CVDF). Ergonomics issues are also addressed in this report, as appropriate. This report follows up and completes the preliminary work accomplished and reported by the Preliminary HFE Analysis report (SNF-2825, Spent Nuclear Fuel Project Cold Vacuum Drying Facility Human Factors Engineering Analysis: Results and Findings). This analysis avoids redundancy of effort except for ensuring that previously recommended HFE design changes have not affected other parts of the system. Changes in one part of the system may affect other parts of the system where those changes were not applied. The final HFE analysis and evaluation of the CVDF human-machine interactions (HMI) was expanded to include: the physical work environment, human-computer interface (HCI) including workstation and software, operator tasks, tools, maintainability, communications, staffing, training, and the overall ability of humans to accomplish their responsibilities, as appropriate. Key focal areas for this report are the process bay operations, process water conditioning (PWC) skid, tank room, and Central Control Room operations. These key areas contain the system safety-class components and are the foundation for the human factors design basis of the CVDF.

  19. U. S. Department of Energy Savannah River Operations Office - SRS Cold War

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Historic Preservation SRS Cold War Historic Preservation SRS Cold War Historic Preservation Background on SRS Cold War Historic Preservation Background: The National Historic Preservation Act (NHPA) of 1966, as amended through 2000, requires that all Federal agencies consider the impacts to historic properties in all their undertakings, such as accelerated clean up. DOE-SR has been consulting with the South Carolina State Historic Preservation Office (SHPO) on NHPA. SHPO is the implementing

  20. Major Cold War Cleanup Milestone Reached at the Savannah River Site |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy Cold War Cleanup Milestone Reached at the Savannah River Site Major Cold War Cleanup Milestone Reached at the Savannah River Site March 29, 2012 - 10:37am Addthis WASHINGTON, DC - Today, the Energy Department announced it has reached a major milestone in the Department's efforts to clean up the Cold War legacy at the Savannah River Site (SRS) in South Carolina, laying the groundwork for closing two underground storage tanks that previously held radioactive liquid waste

  1. Building America Whole-House Solutions for New Home: Fort Devens: Cold

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Climate Market-Rate Townhomes | Department of Energy Building America Whole-House Solutions for New Home: Fort Devens: Cold Climate Market-Rate Townhomes Building America Whole-House Solutions for New Home: Fort Devens: Cold Climate Market-Rate Townhomes Twelve townhomes constructed at a decommissioned army base incorporated efficiency upgrades to achieve a HERS Index score of 41 before adding renewables. PDF icon Fort Devens: Cold Climate Market-Rate Townhomes Targeting HERS Index of 40 -

  2. Building America Whole-House Solutions for New Homes: Affordable Cold

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Climate Infill Housing with Hybrid Insulation Approach | Department of Energy Affordable Cold Climate Infill Housing with Hybrid Insulation Approach Building America Whole-House Solutions for New Homes: Affordable Cold Climate Infill Housing with Hybrid Insulation Approach The City of Wyandotte started a construction program to engage local builders in constructing energy-efficient homes in existing neighborhoods for less than $100/ft2. PDF icon Affordable Cold Climate Infill Housing with

  3. The temperature dependence of ultra-cold neutron wall losses in material

    Office of Scientific and Technical Information (OSTI)

    bottles coated with deuterated polystryene (Conference) | SciTech Connect The temperature dependence of ultra-cold neutron wall losses in material bottles coated with deuterated polystryene Citation Details In-Document Search Title: The temperature dependence of ultra-cold neutron wall losses in material bottles coated with deuterated polystryene Ultra-cold neutrons (UCN) from the LANSCE super-thermal deuterium source were used to fill an acrylic bottle coated with deuterated polystyrene.

  4. Interim report of the Cold Fusion Panel of the Energy Research Advisory Board

    SciTech Connect (OSTI)

    Not Available

    1989-08-01

    This report reviews the current status of cold fusion and makes some preliminary conclusions and recommendations, as requested by the Secretary of Energy.

  5. V-197: Adobe ColdFusion 10 WebSockets Security Bypass Vulnerability

    Office of Energy Efficiency and Renewable Energy (EERE)

    The vulnerability is caused due to an unspecified error and can be exploited to invoke public methods on ColdFusion Components (CFC) using WebSockets

  6. From the Cold War to the War on Cancer | National Nuclear Security...

    National Nuclear Security Administration (NNSA)

    From the Cold War to the War on Cancer | National Nuclear Security Administration Facebook Twitter Youtube Flickr RSS People Mission Managing the Stockpile Preventing Proliferation...

  7. Recovery Act Workers Accomplish Cleanup of Second Cold War Coal Ash Basin

    Broader source: Energy.gov [DOE]

    American Recovery and Reinvestment Act workers recently cleaned up a second basin containing coal ash residues from Cold War operations at the Savannah River Site (SRS).

  8. ALTERNATE REDUCTANT COLD CAP EVALUATION FURNACE PHASE II TESTING

    SciTech Connect (OSTI)

    Johnson, F.; Stone, M.; Miller, D.

    2014-09-03

    Savannah River Remediation (SRR) conducted a Systems Engineering Evaluation (SEE) to determine the optimum alternate reductant flowsheet for the Defense Waste Processing Facility (DWPF). Specifically, two proposed flowsheets (nitric–formic–glycolic and nitric–formic–sugar) were evaluated based upon results from preliminary testing. Comparison of the two flowsheets among evaluation criteria indicated a preference towards the nitric–formic–glycolic flowsheet. Further research and development of this flowsheet eliminated the formic acid, and as a result, the nitric–glycolic flowsheet was recommended for further testing. Based on the development of a roadmap for the nitric–glycolic acid flowsheet, Waste Solidification Engineering (WS-E) issued a Technical Task Request (TTR) to address flammability issues that may impact the implementation of this flowsheet. Melter testing was requested in order to define the DWPF flammability envelope for the nitric-glycolic acid flowsheet. The Savannah River National Laboratory (SRNL) Cold Cap Evaluation Furnace (CEF), a 1/12th scale DWPF melter, was selected by the SRR Alternate Reductant project team as the melter platform for this testing. The overall scope was divided into the following sub-tasks as discussed in the Task Technical and Quality Assurance Plan (TTQAP):  Phase I - A nitric–formic acid flowsheet melter test (unbubbled) to baseline the CEF cold cap and vapor space data to the benchmark melter flammability models;  Phase II - A nitric–glycolic acid flowsheet melter test (unbubbled and bubbled) to: o Define new cold cap reactions and global kinetic parameters in support of the melter flammability model development; o Quantify off-gas surging potential of the feed; o Characterize off-gas condensate for complete organic and inorganic carbon species. After charging the CEF with cullet from Phase I CEF testing, the melter was slurry-fed with glycolic flowsheet based SB6-Frit 418 melter feed at 36% waste loading and was operated continuously for 25 days. Process data was collected throughout testing and included melter operation parameters and off-gas chemistry. In order to generate off-gas data in support of the flammability model development for the nitric-glycolic flowsheet, vapor space steady state testing in the range of ~300-750°C was conducted under the following conditions, (i) 100% (nominal and excess antifoam levels) and 125% stoichiometry feed and (ii) with and without argon bubbling. Adjustments to feed rate, heater outputs and purge air flow were necessary in order to achieve vapor space temperatures in this range. Surge testing was also completed under nominal conditions for four days with argon bubbling and one day without argon bubbling.

  9. ALTERNATE REDUCTANT COLD CAP EVALUATION FURNACE PHASE I TESTING

    SciTech Connect (OSTI)

    Johnson, F.; Miller, D.; Zamecnik, J.; Lambert, D.

    2014-04-22

    Savannah River Remediation (SRR) conducted a Systems Engineering Evaluation (SEE) to determine the optimum alternate reductant flowsheet for the Defense Waste Processing Facility (DWPF). Specifically, two proposed flowsheets (nitric–formic–glycolic and nitric–formic–sugar) were evaluated based upon results from preliminary testing. Comparison of the two flowsheets among evaluation criteria indicated a preference towards the nitric–formic–glycolic flowsheet. Further evaluation of this flowsheet eliminated the formic acid1, and as a result, the nitric–glycolic flowsheet was recommended for further testing. Based on the development of a roadmap for the nitric–glycolic acid flowsheet, Waste Solidification Engineering (WS-E) issued a Technical Task Request (TTR) to address flammability issues that may impact the implementation of this flowsheet. Melter testing was requested in order to define the DWPF flammability envelope for the nitric glycolic acid flowsheet. The Savannah River National Laboratory (SRNL) Cold Cap Evaluation Furnace (CEF), a 1/12th scale DWPF melter, was selected by the SRR Alternate Reductant project team as the melter platform for this testing. The overall scope was divided into the following sub-tasks as discussed in the Task Technical and Quality Assurance Plan (TTQAP):  Phase I - A nitric–formic acid flowsheet melter test (unbubbled) to baseline the Cold Cap Evaluation Furnace (CEF) cold cap and vapor space data to the benchmark melter flammability models  Phase II - A nitric–glycolic acid flowsheet melter test (unbubbled and bubbled) to: o Define new cold cap reactions and global kinetic parameters for the melter flammability models o Quantify off-gas surging potential of the feed o Characterize off-gas condensate for complete organic and inorganic carbon species Prior to startup, a number of improvements and modifications were made to the CEF, including addition of cameras, vessel support temperature measurement, and a heating element near the pour tube. After charging the CEF with cullet from a previous Sludge Batch 6 (SB6) run, the melter was slurry-fed with SB6-Frit 418 melter feed at 36% waste loading and was operated continuously for 6 days. Process data was collected throughout testing and included melter operation variables and off-gas chemistry. In order to satisfy the objective of Phase I testing, vapor space steady testing in the range of ~300°C-700°C was conducted without argon bubbling to baseline the melter data to the existing DWPF melter flammability model. Adjustments to heater outputs, air flows and feed rate were necessary in order to achieve the vapor space temperatures in this range. The results of the Phase I testing demonstrated that the CEF is capable of operating under the low vapor space temperatures A melter pressure of -5 inches of water was not sustained throughout the run, but the melter did remain slightly negative even with the maximum air flows required for the lowest temperature conditions were used. The auxiliary pour tube heater improved the pouring behavior at all test conditions, including reduced feed rates required for the low vapor space testing. Argon bubbling can be used to promote mixing and increase feed rate at multiple conditions. Improvements due to bubbling have been determined previously; however, the addition of the cameras to the CEF allows for visual observation during a range of bubbling configurations. The off-gas analysis system proved to be robust and capable of operating for long durations. The total operational hours on the melter vessel are approximately 385 hours. Dimensional measurements taken prior to Phase I testing and support block temperatures recorded during Phase I testing are available if an extension of service life beyond 1250 hours is desired in the future.

  10. Demonstration of anomalous heat from the cold fusion effect

    SciTech Connect (OSTI)

    Storms, E.

    1995-12-01

    Heat production by an unexpected process is the most challenging aspect of the {open_quotes}cold fusion{close_quotes} phenomenon to accept. Many studies have been done in ways that invite criticism and easy rejection. A few recent studies have attempted to eliminate obvious errors and, thereby, reduce the ease of rejection. In addition, several of these studies have revealed important variables related to improving reproducibility. This paper will describe heat measurements done at the Los Alamos National Laboratory using a closed, pressurized, stirred calorimeter having two independent methods of calibration. Results using several batches of palladium are discussed in terms of those characteristics that lead to reproducibility using the electrolytic loading technique.

  11. Cold-Climate Case Study for Affordable Zero Energy Homes

    SciTech Connect (OSTI)

    Norton, P.; Christensen, C.

    2006-01-01

    This project, supported by the U.S. Department of Energy's Building America Program, is a case study in reaching zero energy within the affordable housing sector in cold climates. The design of the 1200 square foot, 3-bedroom Denver zero energy home carefully combines envelope efficiency, efficient equipment, appliances and lighting, and passive and active solar features to reach the zero energy goal. The home was designed using an early version of the BEOpt building optimization software with additional analysis using DOE2. This engineering approach was tempered by regular discussions with Habitat construction staff and volunteers. These discussions weighed the applicability of the optimized solutions to the special needs and economics of a Habitat house--moving the design towards simple, easily maintained mechanical systems and volunteer-friendly construction techniques.

  12. Cold stress on Russian territory during last global warming

    SciTech Connect (OSTI)

    Vinogradov, V.V.

    1996-12-31

    A great part of Russian territory is characterized by climate discomfort of life. In winter cold stress covers nearly all territory. The purpose of this work is to learn how the climatic discomfort of life is affected by climate change. The effect of global warming for the period 1981--1990 on geographical distribution of bioclimatic indexes by seasons (compared with average figures) is analyzed. Indexes of enthalpy, dry cooling, wind chill, wet cooling, effective temperature, physiological deficit index for monthly average figures were calculated and the data bank for the period 1981--1990 was made up. The indexes of enthalpy, wet cooling, and dry cooling according to Bodman were chosen as the most informative and independent. Maps of the climatic indexes taking into account temperature, humidity and wind speed were made up on the basis of the calculated figures.

  13. SHEAR STRENGTH MEASURING EQUIPMENT EVALUATION AT THE COLD TEST FACILITY

    SciTech Connect (OSTI)

    MEACHAM JE

    2009-09-09

    Retrievals under current criteria require that approximately 2,000,000 gallons of double-shell tank (DST) waste storage space not be used to prevent creating new tanks that might be susceptible to buoyant displacement gas release events (BDGRE). New criteria are being evaluated, based on actual sludge properties, to potentially show that sludge wastes do not exhibit the same BDGRE risk. Implementation of the new criteria requires measurement of in situ waste shear strength. Cone penetrometers were judged the best equipment for measuring in situ shear strength and an A.P. van den berg Hyson 100 kN Light Weight Cone Penetrometer (CPT) was selected for evaluation. The CPT was procured and then evaluated at the Hanford Site Cold Test Facility. Evaluation demonstrated that the equipment with minor modification was suitable for use in Tank Farms.

  14. A strained silicon cold electron bolometer using Schottky contacts

    SciTech Connect (OSTI)

    Brien, T. L. R. Ade, P. A. R.; Barry, P. S.; Dunscombe, C.; Morozov, D. V.; Sudiwala, R. V.; Leadley, D. R.; Myronov, M.; Parker, E. H. C.; Prest, M. J.; Whall, T. E.; Prunnila, M.; Mauskopf, P. D.

    2014-07-28

    We describe optical characterisation of a strained silicon cold electron bolometer (CEB), operating on a 350 mK stage, designed for absorption of millimetre-wave radiation. The silicon cold electron bolometer utilises Schottky contacts between a superconductor and an n{sup ++} doped silicon island to detect changes in the temperature of the charge carriers in the silicon, due to variations in absorbed radiation. By using strained silicon as the absorber, we decrease the electron-phonon coupling in the device and increase the responsivity to incoming power. The strained silicon absorber is coupled to a planar aluminium twin-slot antenna designed to couple to 160?GHz and that serves as the superconducting contacts. From the measured optical responsivity and spectral response, we calculate a maximum optical efficiency of 50% for radiation coupled into the device by the planar antenna and an overall noise equivalent power, referred to absorbed optical power, of 1.110{sup ?16}?W?Hz{sup ?1/2} when the detector is observing a 300?K source through a 4?K throughput limiting aperture. Even though this optical system is not optimized, we measure a system noise equivalent temperature difference of 6?mK?Hz{sup ?1/2}. We measure the noise of the device using a cross-correlation of time stream data, measured simultaneously with two junction field-effect transistor amplifiers, with a base correlated noise level of 300?pV?Hz{sup ?1/2} and find that the total noise is consistent with a combination of photon noise, current shot noise, and electron-phonon thermal noise.

  15. Intermixing in Cu/Ni multilayers induced by cold rolling

    SciTech Connect (OSTI)

    Wang, Z.; Perepezko, J. H.; Larson, D.; Reinhard, D.

    2015-04-28

    Repeated cold rolling was performed on multilayers of Cu60/Ni40 and Cu40/Ni60 foil arrays to study the details of driven atomic scale interfacial mixing. With increasing deformation, there is a significant layer refinement down to the nm level that leads to the formation of a solid solution phase from the elemental end members. Intriguingly, the composition of the solid solution is revealed by an oscillation in the composition profile across the multilayers, which is different from the smoothly varying profile due to thermally activated diffusion. During the reaction, Cu mixed into Ni preferentially compared to Ni mixing into Cu, which is also in contrast to the thermal diffusion behavior. This is confirmed by observations from X-ray diffraction, electron energy loss spectrum and atom probe tomography. The diffusion coefficient induced by cold rolling is estimated as 1.7 × 10{sup −17} m{sup 2}/s, which cannot be attributed to any thermal effect. The effective temperature due to the deformation induced mixing is estimated as 1093 K and an intrinsic diffusivity d{sub b}, which quantifies the tendency towards equilibrium in the absence of thermal diffusion, is estimated as 6.38 × 10{sup −18} m{sup 2}/s. The fraction of the solid solution phase formed is illustrated by examining the layer thickness distribution and is described by using an error function representation. The evolution of mixing in the solid solution phase is described by a simplified sinusoid model, in which the amplitude decays with increased deformation level. The promoted diffusion coefficient could be related to the effective temperature concept, but the establishment of an oscillation in the composition profile is a characteristic behavior that develops due to deformation.

  16. High-Current Cold Cathode Employing Diamond and Related Materials

    SciTech Connect (OSTI)

    Hirshfield, Jay L.

    2014-10-22

    The essence of this project was for diamond films to be deposited on cold cathodes to improve their emission properties. Films with varying morphology, composition, and size of the crystals were deposited and the emission properties of the cathodes that utilize such films were studied. The prototype cathodes fabricated by the methods developed during Phase I were tested and evaluated in an actual high-power RF device during Phase II. These high-power tests used the novel active RF pulse compression system and the X-band magnicon test facility at US Naval Research Laboratory. In earlier tests, plasma switches were employed, while tests under this project utilized electron-beam switching. The intense electron beams required in the switches were supplied from cold cathodes embodying diamond films with varying morphology, including uncoated molybdenum cathodes in the preliminary tests. Tests with uncoated molybdenum cathodes produced compressed X-band RF pulses with a peak power of 91 MW, and a maximum power gain of 16.5:1. Tests were also carried out with switches employing diamond coated cathodes. The pulse compressor was based on use of switches employing electron beam triggering to effect mode conversion. In experimental tests, the compressor produced 165 MW in a ~ 20 ns pulse at ~18× power gain and ~ 140 MW at ~ 16× power gain in a 16 ns pulse with a ~ 7 ns flat-top. In these tests, molybdenum blade cathodes with thin diamond coatings demonstrated good reproducible emission uniformity with a 100 kV, 100 ns high voltage pulse. The new compressor does not have the limitations of earlier types of active pulse compressors and can operate at significantly higher electric fields without breakdown.

  17. 2011 Radiological Monitoring Results Associated with the Advanced Test Reactor Complex Cold Waste Pond

    SciTech Connect (OSTI)

    Mike Lewis

    2012-02-01

    This report summarizes radiological monitoring performed of the Idaho National Laboratory Site's Advanced Test Reactor Complex Cold Waste wastewater prior to discharge into the Cold Waste Pond and of specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit (LA-000161-01, Modification B). All radiological monitoring is performed to fulfill Department of Energy requirements under the Atomic Energy Act.

  18. 2010 Radiological Monitoring Results Associated with the Advance Test Reactor Complex Cold Waste Pond

    SciTech Connect (OSTI)

    mike lewis

    2011-02-01

    This report summarizes radiological monitoring performed of the Idaho National Laboratory Sites Advanced Test Reactor Complex Cold Waste wastewater prior to discharge into the Cold Waste Pond and of specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit (#LA-000161-01, Modification B). All radiological monitoring is performed to fulfill Department of Energy requirements under the Atomic Energy Act.

  19. 2014 Radiological Monitoring Results Associated with the Advanced Test Reactor Complex Cold Waste Pond

    SciTech Connect (OSTI)

    Lewis, Mike

    2015-02-01

    This report summarizes radiological monitoring performed of the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste wastewater prior to discharge into the Cold Waste Pond and of specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit (#LA-000161-01, Modification B). All radiological monitoring is performed to fulfill Department of Energy requirements under the Atomic Energy Act.

  20. 2013 Radiological Monitoring Results Associated with the Advanced Test Reactor Complex Cold Waste Pond

    SciTech Connect (OSTI)

    Mike Lewis

    2014-02-01

    This report summarizes radiological monitoring performed of the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste wastewater prior to discharge into the Cold Waste Pond and of specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit (#LA-000161-01, Modification B). All radiological monitoring is performed to fulfill Department of Energy requirements under the Atomic Energy Act.

  1. Effect of Feeding Rate on the Cold Cap Configuration in a Laboratory-Scale Melter - 13362

    SciTech Connect (OSTI)

    Dixon, Derek R.; Schweiger, Michael J.; Hrma, Pavel; Division of Advanced Nuclear Engineering, Pohang University of Science and Technology, Pohang

    2013-07-01

    High-level-waste melter feed is converted into glass in a joule-heated melter, where it forms a floating layer of reacting feed, called the cold cap. After the glass-forming phase becomes connected, evolving gases produce bubbles that form a foam layer under the feed. The bubbles coalesce into cavities, from which most of the gases are released around the edges of the cold cap while gases also escape through small shafts in the reacting feed. The foam layer insulates the cold cap from the heat transferred from the molten glass below. The cold cap behavior was investigated in a laboratory-scale assembly with a fused silica crucible. A high-alumina waste simulant was fed into the crucible and the feed charging rate was varied from 3 to 7 mL min{sup -1}. After a fixed amount of time (35 min), feed charging was stopped and the crucible was removed from the furnace and quenched on a copper block to preserve the structure of the cold cap during cooling. During the rapid quenching, thermal cracking of the glass and cold cap allowed it to be broken up into sections for analysis. The effect of the charging rate on the height, area and volume of the cold cap was determined. The size of the bubbles collected in the foam layer under the feed increased as the cold cap expanded and the relationship between these bubbles and temperature will be determined for input into a mathematical model. (authors)

  2. Method of manufacturing metallic products such as sheet by cold working and flash annealing

    DOE Patents [OSTI]

    Hajaligol, Mohammad R.; Sikka, Vinod K.

    2000-01-01

    A metallic alloy composition is manufactured into products such as press formed or stamped products or rolled products such as sheet, strip, rod, wire or band by one or more cold working steps with intermediate or final flash annealing. The method can include cold rolling an iron, nickel or titanium aluminide alloy and annealing the cold worked product in a furnace by infrared heating. The flash annealing is preferably carried out by rapidly heating the cold worked product to an elevated temperature for less than one minute. The flash annealing is effective to reduce surface hardness of the cold worked product sufficiently to allow further cold working. The product to be cold worked can be prepared by casting the alloy or by a powder metallurgical technique such as tape casting a mixture of metal powder and a binder, roll compacting a mixture of the powder and a binder or plasma spraying the powder onto a substrate. In the case of tape casting or roll compaction, the initial powder product can be heated to a temperature sufficient to remove volatile components. The method can be used to form a cold rolled sheet which is formed into an electrical resistance heating element capable of heating to 900.degree. C. in less than 1 second when a voltage up to 10 volts and up to 6 amps is passed through the heating element.

  3. Method of manufacturing metallic products such as sheet by cold working and flash anealing

    DOE Patents [OSTI]

    Hajaligol, Mohammad R.; Sikka, Vinod K.

    2001-01-01

    A metallic alloy composition is manufactured into products such as press formed or stamped products or rolled products such as sheet, strip, rod, wire or band by one or more cold working steps with intermediate or final flash annealing. The method can include cold rolling an iron, nickel or titanium aluminide alloy and annealing the cold worked product in a furnace by infrared heating. The flash annealing is preferably carried out by rapidly heating the cold worked product to an elevated temperature for less than one minute. The flash annealing is effective to reduce surface hardness of the cold worked product sufficiently to allow further cold working. The product to be cold worked can be prepared by casting the alloy or by a powder metallurgical technique such as tape casting a mixture of metal powder and a binder, roll compacting a mixture of the powder and a binder or plasma spraying the powder onto a substrate. In the case of tape casting or roll compaction, the initial powder product can be heated to a temperature sufficient to remove volatile components. The method can be used to form a cold rolled sheet which is formed into an electrical resistance heating element capable of heating to 900.degree. C. in less than 1 second when a voltage up to 10 volts and up to 6 amps is passed through the heating element.

  4. 2012 Radiological Monitoring Results Associated with the Advanced Test Reactor Complex Cold Waste Pond

    SciTech Connect (OSTI)

    Mike Lewis

    2013-02-01

    This report summarizes radiological monitoring performed of the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste wastewater prior to discharge into the Cold Waste Pond and of specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit (#LA-000161-01, Modification B). All radiological monitoring is performed to fulfill Department of Energy requirements under the Atomic Energy Act.

  5. Regulatory Networks Controlling Plant Cold Acclimation or Low Temperature Regulatory Networks Controlling Cold Acclimation in Arabidopsis (2011 JGI User Meeting)

    SciTech Connect (OSTI)

    Thomashow, Mike

    2011-03-23

    The U.S. Department of Energy Joint Genome Institute (JGI) invited scientists interested in the application of genomics to bioenergy and environmental issues, as well as all current and prospective users and collaborators, to attend the annual DOE JGI Genomics of Energy & Environment Meeting held March 22-24, 2011 in Walnut Creek, Calif. The emphasis of this meeting was on the genomics of renewable energy strategies, carbon cycling, environmental gene discovery, and engineering of fuel-producing organisms. The meeting features presentations by leading scientists advancing these topics. Mike Thomashow of Michigan State University gives a presentation on on "Low Temperature Regulatory Networks Controlling Cold Acclimation in Arabidopsis" at the 6th annual Genomics of Energy & Environment Meeting on March 23, 2011.

  6. Regulatory Networks Controlling Plant Cold Acclimation or Low Temperature Regulatory Networks Controlling Cold Acclimation in Arabidopsis (2011 JGI User Meeting)

    ScienceCinema (OSTI)

    Thomashow, Mike

    2011-06-03

    The U.S. Department of Energy Joint Genome Institute (JGI) invited scientists interested in the application of genomics to bioenergy and environmental issues, as well as all current and prospective users and collaborators, to attend the annual DOE JGI Genomics of Energy & Environment Meeting held March 22-24, 2011 in Walnut Creek, Calif. The emphasis of this meeting was on the genomics of renewable energy strategies, carbon cycling, environmental gene discovery, and engineering of fuel-producing organisms. The meeting features presentations by leading scientists advancing these topics. Mike Thomashow of Michigan State University gives a presentation on on "Low Temperature Regulatory Networks Controlling Cold Acclimation in Arabidopsis" at the 6th annual Genomics of Energy & Environment Meeting on March 23, 2011. «

  7. Creep-Rupture Behavior and Recrystallization in Cold-Bent Boiler Tubing for USC Applications

    SciTech Connect (OSTI)

    Shingledecker, John P

    2008-01-01

    Creep-rupture experiments were conducted on candidate Ultrasupercritical (USC) alloy tubes to evaluate the effects of cold-work and recrystallization during high-temperature service. These creep tests were performed by internally pressurizing cold-bent boiler tubes at 775 C for times up to 8000 hours. The bends were fabricated with cold-work levels beyond the current ASME Boiler and Pressure Vessel (ASME B&PV) Code Section I limits for austenitic stainless steels. Destructive metallographic evaluation of the crept tube bends was used to determine the effects of cold-work and the degree of recrystallization. The metallographic analysis combined with an evaluation of the creep and rupture data suggest that solid-solution strengthened nickel-based alloys can be fabricated for high-temperature service at USC conditions utilizing levels of cold-work higher than the current allowed levels for austenitic stainless steels.

  8. Delusion is the better part of Grandeur: Lessons learned from cold fusion

    SciTech Connect (OSTI)

    Taubes, G.

    1995-04-01

    On March 23, 1989, Stan Pons and Martin Fleischmann, backed by the administration of the University of Utah, claimed the discovery of cold nuclear fusion, a phenomenon that defied known physical law by 50 to 60 orders of magnitude and was quickly (although not that quickly) shown to be dead wrong. With that in mind, the proponents of cold fusion have already held a Fourth International Conference on Cold Fusion. The question, of course, is if cold fusion does not exist, what are these people doing, and why? And secondly, what`s the matter with science journalism that a phenomenon like cold fusion is not only covered so poorly, but that the journalists are as responsible as anyone else for making it happen?

  9. Incorporating Cold Cap Behavior in a Joule-heated Waste Glass Melter Model

    SciTech Connect (OSTI)

    Varija Agarwal; Donna Post Guillen

    2013-08-01

    In this paper, an overview of Joule-heated waste glass melters used in the vitrification of high level waste (HLW) is presented, with a focus on the cold cap region. This region, in which feed-to-glass conversion reactions occur, is critical in determining the melting properties of any given glass melter. An existing 1D computer model of the cold cap, implemented in MATLAB, is described in detail. This model is a standalone model that calculates cold cap properties based on boundary conditions at the top and bottom of the cold cap. Efforts to couple this cold cap model with a 3D STAR-CCM+ model of a Joule-heated melter are then described. The coupling is being implemented in ModelCenter, a software integration tool. The ultimate goal of this model is to guide the specification of melter parameters that optimize glass quality and production rate.

  10. OTEC Advanced Composite Cold Water Pipe: Final Technical Report

    SciTech Connect (OSTI)

    Dr. Alan Miller; Matthew Ascari

    2011-09-12

    Ocean Thermal Energy Conversion can exploit natural temperature gradients in the oceans to generate usable forms of energy (for example, cost-competitive baseload electricity in tropical regions such as Hawaii) free from fossil fuel consumption and global warming emissions.The No.1 acknowledged challenge of constructing an OTEC plant is the Cold Water Pipe (CWP), which draws cold water from 1000m depths up to the surface, to serve as the coolant for the OTEC Rankine cycle. For a commercial-scale plant, the CWP is on the order of 10m in diameter.This report describes work done by LMSSC developing the CWP for LM MS2 New Ventures emerging OTEC business. The work started in early 2008 deciding on the minimum-cost CWP architecture, materials, and fabrication process. In order to eliminate what in previous OTEC work had been a very large assembly/deployment risk, we took the innovative approach of building an integral CWP directly from theOTEC platform and down into the water. During the latter half of 2008, we proceeded to a successful small-scale Proof-of-Principles validation of the new fabrication process, at the Engineering Development Lab in Sunnyvale. During 2009-10, under the Cooperative Agreement with the US Dept. of Energy, we have now successfully validated key elements of the process and apparatus at a 4m diameter scale suitable for a future OTEC Pilot Plant. The validations include: (1) Assembly of sandwich core rings from pre-pultruded hollow 'planks,' holding final dimensions accurately; (2) Machine-based dispensing of overlapping strips of thick fiberglass fabric to form the lengthwise-continuous face sheets, holding accurate overlap dimensions; (3) Initial testing of the fabric architecture, showing that the overlap splices develop adequate mechanical strength (work done under a parallel US Naval Facilities Command program); and (4) Successful resin infusion/cure of 4m diameter workpieces, obtaining full wet-out and a non-discernable knitline between successive stepwise infusions.

  11. Barrier for cold-fusion production of superheavy elements

    SciTech Connect (OSTI)

    Ichikawa, Takatoshi; Iwamoto, Akira; Moeller, Peter; Sierk, Arnold J.

    2005-04-01

    We estimate the fusion-barrier height B{sub fu}{sup (two-body)} for approaching ions in cold-fusion reactions in a model where the projectile deformation and quadrupole zero-point vibrational energy are taken into account. This barrier height is defined as the barrier energy at the target and projectile separation distance where an original oblate deformation of projectile and/or target caused by a repulsive Coulomb force turns into a large prolate deformation caused by the attractive nuclear force as the target and projectile come closer. The instability develops before touching because the attractive short-range nuclear force overcomes the repulsive Coulomb force and the shape-stabilizing effect of shell structure. The shell structure of the doubly magic {sup 208}Pb target is sufficiently strong that its shape remains very close to spherical in all cases studied here. The fusion potential for approaching ions in the two-body channel is calculated in the macroscopic-microscopic model with the quadrupole vibrational zero-point energy obtained in the WKB approximation. We compare our results with data from 10 experimental cold-fusion reactions and with the Bass barriers. Differences and similarities between the Yukawa-plus-exponential model and the Bass model are discussed. We also calculate five-dimensional potential-energy surfaces for the single compound system and show that well-established fission and fusion valleys are both present. For heavy systems, B{sub fu}{sup (two-body)} becomes lower than the fission barrier just beyond the ground state of the compound system. In the vicinity of this transition, the optimum collision energy for formation of evaporation residues can be expected to depend in a delicate fashion on the interplay among B{sub fu}{sup (two-body)}, the fusion valley, the fission barrier of the compound system, and the one- and two-neutron separation energies S{sub 1n} and S{sub 2n}. We discuss these issues in detail and calculate fission-barrier heights. Except for reactions in which the projectile is doubly magic or near doubly magic, the calculated quantities are consistent with the observed optimal energies for evaporation-residue formation.

  12. Abstracts of papers presented at the LVIII Cold Spring Harbor Symposium on quantitative Biology: DNA and chromosomes

    SciTech Connect (OSTI)

    Not Available

    1993-12-31

    This volume contains the abstracts of oral and poster presentations made at the LVIII Cold Spring Harbor Symposium on Quantitative Biology entitles DNA & Chromosomes. The meeting was held June 2--June 9, 1993 at Cold Spring Harbor, New York.

  13. HERSCHEL REVEALS MASSIVE COLD CLUMPS IN NGC 7538

    SciTech Connect (OSTI)

    Fallscheer, C.; Di Francesco, J.; Sadavoy, S.; Reid, M. A.; Martin, P. G.; Nguyen-Luong, Q.; Hill, T.; Hennemann, M.; Motte, F.; Men'shchikov, A.; Andre, Ph.; Konyves, V.; Sauvage, M.; Griffin, M.; Rygl, K. L. J.; Benedettini, M.; Schneider, N.; Anderson, L. D. [Laboratoire d'Astrophysique de Marseille, CNRS and others

    2013-08-20

    We present the first overview of the Herschel observations of the nearby high-mass star-forming region NGC 7538, taken as part of the Herschel imaging study of OB young stellar objects (HOBYS) Key Programme. These PACS and SPIRE maps cover an approximate area of one square degree at five submillimeter and far-infrared wavebands. We have identified 780 dense sources and classified 224 of those. With the intention of investigating the existence of cold massive starless or class 0-like clumps that would have the potential to form intermediate- to high-mass stars, we further isolate 13 clumps as the most likely candidates for follow-up studies. These 13 clumps have masses in excess of 40 M{sub Sun} and temperatures below 15 K. They range in size from 0.4 pc to 2.5 pc and have densities between 3 Multiplication-Sign 10{sup 3} cm{sup -3} and 4 Multiplication-Sign 10{sup 4} cm{sup -3}. Spectral energy distributions are then used to characterize their energetics and evolutionary state through a luminosity-mass diagram. NGC 7538 has a highly filamentary structure, previously unseen in the dust continuum of existing submillimeter surveys. We report the most complete imaging to date of a large, evacuated ring of material in NGC 7538 which is bordered by many cool sources.

  14. Solid state consolidation nanocrystalline copper-tungsten using cold spray

    SciTech Connect (OSTI)

    Hall, Aaron Christopher; Sarobol, Pylin; Argibay, Nicolas; Clark, Blythe; Diantonio, Christopher

    2015-09-01

    It is well known that nanostructured metals can exhibit significantly improved properties compared to metals with conventional grain size. Unfortunately, nanocrystalline metals typically are not thermodynamically stable and exhibit rapid grain growth at moderate temperatures. This severely limits their processing and use, making them impractical for most engineering applications. Recent work has shown that a number of thermodynamically stable nanocrystalline metal alloys exist. These alloys have been prepared as powders using severe plastic deformation (e.g. ball milling) processes. Consolidation of these powders without compromise of their nanocrystalline microstructure is a critical step to enabling their use as engineering materials. We demonstrate solid-state consolidation of ball milled copper-tantalum nanocrystalline metal powder using cold spray. Unfortunately, the nanocrystalline copper-tantalum powder that was consolidated did not contain the thermodynamically stable copper-tantalum nanostructure. Nevertheless, this does this demonstrates a pathway to preparation of bulk thermodynamically stable nanocrystalline copper-tantalum. Furthermore, it demonstrates a pathway to additive manufacturing (3D printing) of nanocrystalline copper-tantalum. Additive manufacturing of thermodynamically stable nanocrystalline metals is attractive because it enables maximum flexibility and efficiency in the use of these unique materials.

  15. Compressor Selection and Equipment Sizing for Cold Climate Heat Pumps

    SciTech Connect (OSTI)

    Shen, Bo; Abdelaziz, Omar; Rice, C Keith

    2014-01-01

    In order to limit heating capacity degradation at -25 C (-13 F) ambient to 25%, compared to the nominal rating point capacity at 8.3 C (47 F), an extensive array of design and sizing options were investigated, based on fundamental equipment system modeling and building energy simulation. Sixteen equipment design options were evaluated in one commercial building and one residential building, respectively in seven cities. The energy simulation results were compared to three baseline cases: 100% electric resistance heating, a 9.6 HSPF single-speed heat pump unit, and 90% AFUE gas heating system. The general recommendation is that variable-speed compressors and tandem compressors, sized such that their rated heating capacity at a low speed matching the building design cooling load, are able to achieve the capacity goal at low ambient temperatures by over-speeding, for example, a home with a 3.0 ton design cooling load, a tandem heat pump could meet this cooling load running a single compressor, while running both compressors to meet heating load at low ambient temperatures in a cold climate. Energy savings and electric resistance heat reductions vary with building types, energy codes and climate zones. Oversizing a heat pump can result in larger energy saving in a less energy efficient building and colder regions due to reducing electric resistance heating. However, in a more energy-efficient building or for buildings in warmer climates, one has to consider balance between reduction of resistance heat and addition of cyclic loss.

  16. Latest cold fusion results fail to win over skeptics

    SciTech Connect (OSTI)

    Dagani, R.

    1993-06-14

    It's been four years since electrochemists Martin Fleischmann and Stanley Pons polarized the scientific community into two camps: those who believe they discovered a new phenomenon, dubbed cold fusion, and those who do not. Now, a new calorimetry paper coauthored by Pons and Fleischmann has dumped fresh fuel on the fire, but it doesn't seem to be changing anyone's mind. The paper in question, titled [open quotes]Calorimetry of the Pd-D[sub 2]O system: from simplicity via complications to simplicity[close quotes], was published in the May 3 issue of Physics Letters. As in their earlier work at the University of Utah, Pons and Fleischmann, now working in a Japanese-funded laboratory in the south of France, electrolyze heavy water in open cells containing a palladium cathode and a platinum anode. And, as before, they observe the production of high rates of excess enthalpy--more enthalpy (heat content) than was put into the system and more, they say, than can be accounted for by the chemical changes occurring. So much heat is generated, in fact, that the electrolyte (D[sub 2]O and Li[sub 2]SO[sub 4]) eventually begins to boil. This paper describes the continuing controversy.

  17. Warm and cold fermionic dark matter via freeze-in

    SciTech Connect (OSTI)

    Klasen, Michael; Yaguna, Carlos E. E-mail: carlos.yaguna@uni-muenster.de

    2013-11-01

    The freeze-in mechanism of dark matter production provides a simple and intriguing alternative to the WIMP paradigm. In this paper, we analyze whether freeze-in can be used to account for the dark matter in the so-called singlet fermionic model. In it, the SM is extended with only two additional fields, a singlet scalar that mixes with the Higgs boson, and the dark matter particle, a fermion assumed to be odd under a Z{sub 2} symmetry. After numerically studying the generation of dark matter, we analyze the dependence of the relic density with respect to all the free parameters of the model. These results are then used to obtain the regions of the parameter space that are compatible with the dark matter constraint. We demonstrate that the observed dark matter abundance can be explained via freeze-in over a wide range of masses extending down to the keV range. As a result, warm and cold dark matter can be obtained in this model. It is also possible to have dark matter masses well above the unitarity bound for WIMPs.

  18. The Performance House - A Cold Climate Challenge Home

    SciTech Connect (OSTI)

    Puttagunta, S.; Grab, J.; Williamson, J.

    2013-08-01

    Working with builder partners on test homes allows for vetting of whole-house building strategies to eliminate any potential unintended consequences prior to implementing these solution packages on a production scale. To support this research, CARB partnered with Preferred Builders Inc. on a high-performance test home in Old Greenwich, CT. The philosophy and science behind the 2,700 ft2 "Performance House" was based on the premise that homes should be safe, healthy, comfortable, durable, efficient, and adapt with the homeowners. The technologies and strategies used in the "Performance House" were not cutting-edge, but simply "best practices practiced". The focus was on simplicity in construction, maintenance, and operation. When seeking a 30% source energy savings targets over a comparable 2009 IECC code-built home in the cold climate zone, nearly all components of a home must be optimized. Careful planning and design are critical. To help builders and architects seeking to match the performance of this home, a step-by-step guide through the building shell components of DOE's Challenge Home are provided in a pictorial story book. The end result was a DOE Challenge Home that achieved a HERS Index Score of 20 (43 without PV, the minimum target was 55 for compliance). This home was also awarded the 2012 HOBI for Best Green Energy Efficient Home from the Home Builders & Remodelers Association of Connecticut.

  19. Air Source Heat Pumps for Cold Climate Applications: Recent U. S. R&D Results from IEA HPP Annex 41

    SciTech Connect (OSTI)

    Baxter, Van D; Groll, Dr. Eckhard A.; Shen, Bo

    2014-01-01

    Air source heat pumps are easily applied to buildings almost anywhere. They are widespread in milder climate regions but their use in cold regions is hampered due to low efficiency and heating capacity at cold outdoor temperatures. This article describes selected R&D activities aimed at improving their cold weather performance.

  20. The Department of Energy Announces Major Cold War Legacy Waste Cleanup

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Milestone | Department of Energy The Department of Energy Announces Major Cold War Legacy Waste Cleanup Milestone The Department of Energy Announces Major Cold War Legacy Waste Cleanup Milestone September 28, 2011 - 8:54am Addthis CARLSBAD, NM - The U.S. Department of Energy today announced that the Waste Isolation Pilot Plant (WIPP) received its 10,000th shipment of transuranic (TRU) waste over the weekend. This marks an important milestone in DOE's mission to clean up the country's Cold

  1. Examination of claims of Miles et al. in Pons-Fleischmann-type cold fusion experiments

    SciTech Connect (OSTI)

    Jones, S.E.; Hansen, L.D.

    1995-05-04

    In cold fusion experiments conducted at the Naval Research Laboratory in China Lake, M. H. Miles and co-workers claim to have produced excess heat correlated with helium-4 production, X-rays, and Geiger-counter excitation. However, scrutiny of the claims shows that unreliable calorimetric and nuclear-product detection methods were used. Moreover, inconsistencies and errors are found in the data and data analysis. The juxtaposition of several poor techniques and inconsistent data does not make a compelling case for cold fusion. We conclude that the evidence for cold fusion from these efforts is far from compelling. 20 refs., 2 figs., 2 tabs.

  2. DEVELOPMENT OF A HIGH PERFORMANCE COLD CLIMATE HEAT PUMP

    SciTech Connect (OSTI)

    Horton, W. Travis; Groll, Eckhard A.; Braun, James E.

    2014-06-01

    The primary goals of the proposed project were to develop, test, and evaluate a high performance and cost-effective vapor compression air-source heat pump for use in cold climate regions. Vapor compression heat pumps are a proven technology, and have been used for many years to meet heating requirements for buildings in residential, commercial, and industrial applications. However, in climate regions that experience very low outdoor ambient temperatures both the heating capacity and coefficient of performance (COP) of traditional air-source vapor compression heat pumps drops dramatically with a decrease in the outdoor air temperature. The efficiency of heat pumping equipment has improved substantially over the past 20 years; however, the efficiencies of the highest rated equipment on the market are approaching practical limits that cannot be surpassed without modifications to the basic cycle and possibly the use of additional hardware. In this report, three technologies to improve the efficiency of vapor compression systems are described. These are a) vapor injected compression, b) oil flooded compression and c) hybrid flow control of the evaporator. Compressor prototypes for both, oil flooded and vapor injected compression were developed by Emerson Climate Technologies. For the oil flooded compressor, the oil injection port location was optimized and an internal oil separator was added using several design iterations. After initial testing at Emerson Climate Technologies, further testing was done at Purdue University, and compressor models were developed. These models were then integrated into a system model to determine the achievable improvement of seasonal energy efficiency (SEER) for Minneapolis (Minnesota) climate. For the oil flooded compression, a 34% improvement in seasonal energy efficiency was found while a 21% improvement in seasonal energy efficiency ratio was found for the vapor injected compression. It was found that one benefit of both tested compression technologies is a lower discharge temperature, which allows for continued operation at lower ambient temperatures. A bin analysis of the vapor injected prototype cold climate heat pump predicts a 6% improvement in HSPF for Minneapolis. This improvement is mainly a result of the increased capacity of the system for active vapor injection. For the oil flooded system, a slightly larger performance improvement is predicted, in this case mostly caused by an increase in heating COP. Based on an economic analysis of these results, the maximum additional cost of the system changes, for the Minneapolis location, are $430 for the vapor injected system and $391 for the oil flooded system. These estimates assume that a 3-year simple payback period is accepted by the customer. For the hybrid flow control of evaporators, a new type of balancing valve was developed together with Emerson Climate technologies to reduce the cost of the control scheme. In contrast to conventional stepper motor valves, this valve requires less cables and can be driven by a cheaper output circuit on the control board. The correct valve size was determined in a dedicated test stand in several design iterations. The performance benefits of the hybrid control of the evaporator coil were determined for clean coil conditions as well as with partial blockage of the air inlet grille and under frosting conditions. For clean coil conditions, the benefits in terms of COP and capacity are negligible. However, significant benefits were noted for severely air-maldistributed operating conditions. For the H2-test, the maximum COP improvement of 17% along with a capacity improvement of nearly 40% was observed. Overall, the hybrid control scheme leads to a significant amount of performance improvement, if the air inlet conditions to the evaporator are maldistributed.

  3. Integrated Pilot Plant for a Large Cold Crucible Induction Melter

    SciTech Connect (OSTI)

    Do Quang, R.; Jensen, A.; Prod'homme, A.; Fatoux, R.; Lacombe, J.

    2002-02-26

    COGEMA has been vitrifying high-level liquid waste produced during nuclear fuel reprocessing on an industrial scale for over 20 years, with two main objectives: containment of the long lived fission products and reduction of the final volume of waste. Research performed by the French Atomic Energy Commission (CEA) in the 1950s led to the selection of borosilicate glass as the most suitable containment matrix for waste from spent nuclear fuel and to the development of the induction melter technology. This was followed by the commissioning of the Marcoule Vitrification Facility (AVM) in 1978. The process was implemented at a larger scale in the late 1980s in the R7 and T7 facilities of the La Hague reprocessing plant. COGEMA facilities have produced more than 11,000 high level glass canisters, representing more than 4,500 metric tons of glass and 4.5 billion curies. To further improve the performance of the vitrification lines in the R7 and T7 facilities, the CEA and COGEMA have been developing the Cold Crucible Melter (CCM) technology since the 1980s. This technology benefits from the 20 years of COGEMA HLW vitrification experience and ensures a virtually unlimited equipment service life and extensive flexibility in dealing with different types of waste. The high specific power directly transferred by induction to the melt allows high operating temperatures without any impact on the process equipment. In addition, the mechanical stirring of the melter significantly reduces operating constraints. COGEMA is already providing the CCM technology to international customers for nuclear and non-nuclear applications and plans to implement it in the La Hague vitrification plant for the vitrification of highly concentrated and corrosive solutions produced by uranium/molybdenum fuel reprocessing. The paper presents the CCM project that led to the building and start-up of this evolutionary and flexible pilot plant. It also describes the plant's technical characteristics and reports commissioning results.

  4. The Phoenix stream: A cold stream in the southern hemisphere

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Balbinot, E.

    2016-03-17

    In this study, we report the discovery of a stellar stream in the Dark Energy Survey (DES) Year 1 (Y1A1) data. The discovery was made through simple color-magnitude filters and visual inspection of the Y1A1 data. We refer to this new object as the Phoenix stream, after its resident constellation. After subtraction of the background stellar population we detect a clear signal of a simple stellar population. By fitting the ridge line of the stream in color-magnitude space, we find that a stellar population with agemore » $$\\tau=11.5\\pm0.5$$ Gyr and $[Fe/H]<-1.6$ located 17.5$$\\pm$$0.9 kpc from the Sun gives an adequate description of the stream stellar population. The stream is detected over an extension of 8$$^{\\circ}.$$1 (2.5 kpc) and has a width of $$\\sim$$54 pc assuming a Gaussian profile, indicating that a globular cluster is a probable progenitor. There is no known globular cluster within 5 kpc compatible with being the progenitor of the stream, assuming that the stream traces its orbit. We examined overdensities along the stream, however no obvious counterpart bound stellar system is visible in the coadded images. We also find overdensities along the stream that appear to be symmetrically distributed - consistent with the epicyclic overdensity scenario for the formation of cold streams - as well as a misalignment between the Northern and Southern part of stream. Despite the close proximity we find no evidence that this stream and the halo cluster NGC 1261 have a common accretion origin linked to the recently found EriPhe overdensity (Li et al. 2016).« less

  5. BEAM TRANSPORT AND STORAGE WITH COLD NEUTRAL ATOMS AND MOLECULES

    SciTech Connect (OSTI)

    Walstrom, Peter L.

    2012-05-15

    A large class of cold neutral atoms and molecules is subject to magnetic field-gradient forces. In the presence of a field, hyperfine atomic states are split into several Zeeman levels. The slopes of these curves vs. field are the effective magnetic moments. By means of optical pumping in a field, Zeeman states of neutral lithium atoms and CaH molecules with effective magnetic moments of nearly {+-} one Bohr magneton can be selected. Particles in Zeeman states for which the energy increases with field are repelled by increasing fields; particles in states for which the energy decreases with field are attracted to increasing fields. For stable magnetic confinement, field-repelled states are required. Neutral-particle velocities in the present study are on the order of tens to hundreds of m/s and the magnetic fields needed for transport and injection are on the order of in the range of 0.01-1T. Many of the general concepts of charged-particle beam transport carry over into neutral particle spin-force optics, but with important differences. In general, the role of bending dipoles in charged particle optics is played by quadrupoles in neutral particle optics; the role of quadrupoles is played by sextupoles. The neutralparticle analog of charge-exchange injection into storage rings is the use of lasers to flip the state of particles from field-seeking to field-repelled. Preliminary tracking results for two neutral atom/molecule storage ring configurations are presented. It was found that orbit instabilities limit the confinment time in a racetrack-shaped ring with discrete magnetic elements with drift spaces between them; stable behavior was observed in a toroidal ring with a continuous sextupole field. An alternative concept using a linear sextupole or octupole channel with solenoids on the ends is presently being considered.

  6. Cold cap subsidence for in situ vitrification and electrodes therefor

    DOE Patents [OSTI]

    Buelt, James L.; Carter, John G.; Eschbach, Eugene A.; FitzPatrick, Vincent F.; Koehmstedt, Paul L.; Morgan, William C.; Oma, Kenton H.; Timmerman, Craig L.

    1992-01-01

    An electrode for use in in situ vitrification of soil comprises a molybdenum rod received within a conductive sleeve or collar formed of graphite. Electrodes of this type are placed on either side of a region containing buried waste material and an electric current is passed therebetween for vitrifying the soil between the electrodes. The graphite collar enhances the thermal conductivity of the electrode, bringing heat to the surface, and preventing the formation of a cold cap of material above the ground surface. The annulus between the molybdenum rod electrode and the graphite collar is filled with a conductive ceramic powder of a type that sinters upon the molybdenum rod, protecting the same from oxidation as the graphite material is consumed, or a metal powder which liquifies at operating temperatures. The molybdenum rod in the former case may be coated with an oxidation protectant, e.g. of molybdenum disilicide. As insulative blanket is suitably placed on the surface of the soil during processing to promote subsidence by allowing off-gassing and reducing surface heat loss. In other embodiments, connection to vitrification electrodes is provided below ground level to avoid loss of connection due to electrodes deterioration, or a sacrificial electrode may be employed when operation is started. Outboard electrodes can be utilized to square up the vitrified area. Further, the center of the molybdenum rod can be made hollow and filled with a powdered metal, such as copper, which liquifies at operating temperatures. In one embodiment, the molybdenum rod and the graphite collar are physically joined at the bottom.

  7. Cold collisions of highly rotationally excited CO{sub 2} with He: The prospects for cold chemistry with super-rotors

    SciTech Connect (OSTI)

    Al-Qady, W. H.; Forrey, R. C.; Yang, B. H.; Stancil, P. C.; Balakrishnan, N.

    2011-11-15

    Building on recent advances in ultrafast lasers and methods to slow molecules, an experiment is proposed to produce translationally cold CO{sub 2} super-rotors (j{approx}200) by combining an optical centrifuge with helium-buffer-gas cooling. Quantum mechanical calculations of the complex scattering length for He-CO{sub 2} collisions demonstrate that the efficiency of rotational quenching decreases rapidly with increasing rotational excitation j in the ultracold regime. Extrapolating to helium cryogenic temperatures, rotational quenching is predicted to remain inefficient up to {approx}1 K, allowing for the possible creation of a beam of translationally cold, rotationally hot molecules.

  8. Building America Best Practices Series: Volume 3; Builders and Buyers Handbook for Improving New Home Efficiency, Comfort, and Durability in Cold and Very Cold Climates

    SciTech Connect (OSTI)

    Not Available

    2005-08-01

    This best practices guide is part of a series produced by Building America. The guide book is a resource to help builders large and small build high-quality, energy-efficient homes that achieve 30% energy savings in space conditioning and water heating in the cold and very cold climates. The savings are in comparison with the 1993 Model Energy Code. The guide contains chapters for every member of the builder's team-from the manager to the site planner to the designers, site supervisors, the trades, and marketers. There is also a chapter for homeowners on how to use the book to provide help in selecting a new home or builder.

  9. EBSD study on crystallographic texture and microstructure development of cold-rolled FePd alloy

    SciTech Connect (OSTI)

    Lin, Hung-Pin; Ng, Tin-San; Kuo, Jui-Chao; Chen, Yen-Chun; Chen, Chun-Liang; Ding, Shi-Xuan

    2014-07-01

    The crystallographic texture and microstructure of FePd alloy after cold-rolling deformation were investigated using electron backscatter diffraction. The major orientations of twin copper and copper after 50% thickness reduction were observed in face-centered cubic-disordered FePd alloy, whereas the main orientation was obtained from brass type after 90% cold rolling. Increase in cold rolling resulted in the change of preferred orientation from copper to brass. Decrease in orientation intensity of copper also increased that of Goss and brass. - Highlights: • The evolution of texture and microstructure in FePd alloy was investigated after cold rolling using EBSD. • Increasing in reduction leads to the change of texture from Copper-type to Brass-type. • The reduction of Copper orientation results in increasing in Goss and Brass orientations.

  10. EM’s December Newsletter Recaps Cold War Cleanup Accomplishments in 2013

    Broader source: Energy.gov [DOE]

    On Dec. 19, EM completed demolition of the 4.8 million-square-foot Building K-25 at Oak Ridge, a milestone that capped a busy and successful 2013 for the Cold War cleanup program.

  11. Light-Weight, Low-Cost, Single-Phase, Liquid-Cooled Cold Plate (Presentation)

    SciTech Connect (OSTI)

    Narumanchi, S.

    2013-07-01

    This presentation, 'Light-Weight, Low-Cost, Single-Phase Liquid-Cooled Cold Plate,' directly addresses program goals of increased power density, specific power, and lower cost of power electronics components through improved thermal management.

  12. Idaho Cold War Waste Removal Advancing as Work on Eighth Area...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Danielle Miller, (208) 569-7806 Erik Simpson, (208) 390-9464 For Immediate Release: January 13, 2014 Idaho Cold War Waste Removal Advancing as Work on Eighth Area Begins IDAHO...

  13. Assessment of cold-climate environmental research priorities. Appendixes A, B

    SciTech Connect (OSTI)

    States, J.B.

    1983-04-01

    These appendices present research plans in the areas of air pollution, water contamination/consumption, habitat modification and waste management that are relevant to the EPA's cold regions program. (ACR)

  14. Idaho site completes demolition of Cold War-era nuclear fuel...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Joint News Release For Immediate Release Date: December 22, 2011 Media Contact: Erik Simpson, (208) 360-0426 Idaho site completes demolition of Cold War-era nuclear fuel...

  15. Compact, Light-Weight, Single-Phase, Liquid-Cooled Cold Plate...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    and Peer Evaluation PDF icon ape039narumanchi2011p.pdf More Documents & Publications Compact, Light-Weight, Single-Phase, Liquid-Cooled Cold Plate Advanced Liquid Cooling R&D

  16. Cooled electronic system with thermal spreaders coupling electronics cards to cold rails

    DOE Patents [OSTI]

    Chainer, Timothy J; Gaynes, Michael A; Graybill, David P; Iyengar, Madhusudan K; Kamath, Vinod; Kochuparambil, Bejoy J; Schmidt, Roger R; Schultz, Mark D; Simco, Daniel P; Steinke, Mark E

    2013-07-23

    Liquid-cooled electronic systems are provided which include an electronic assembly having an electronics card and a socket with a latch at one end. The latch facilitates securing of the card within the socket or removal of the card from the socket. A liquid-cooled cold rail is disposed at the one end of the socket, and a thermal spreader couples the electronics card to the cold rail. The thermal spreader includes first and second thermal transfer plates coupled to first and second surfaces on opposite sides of the card, and thermally conductive extensions extending from end edges of the plates, which couple the respective transfer plates to the liquid-cooled cold rail. The thermally conductive extensions are disposed to the sides of the latch, and the card is securable within or removable from the socket using the latch without removing the cold rail or the thermal spreader.

  17. T-549: Adobe ColdFusion 9.0.1 CHF1 and earlier

    Broader source: Energy.gov [DOE]

    Cross-site scripting (XSS) vulnerability in Adobe ColdFusion before 9.0.1 CHF1 allows remote attackers to inject arbitrary web script or HTML via vectors involving a "tag script.

  18. Idaho Site Completes Demolition of Cold War-era Nuclear Fuel Reprocessing Facility

    Broader source: Energy.gov [DOE]

    A gravel mound, larger than half a city block and several feet thick, is the only visible feature that remains at the site of a Cold War-era spent nuclear fuel reprocessing facility at the U.S....

  19. Cold Crucible Induction Melter Technology: Results of Laboratory Directed Research and Development

    SciTech Connect (OSTI)

    Gombert, Dirk; Richardson, John Grant

    2001-09-01

    This report provides a review of cold crucible induction melter (CCIM) technology and presents summaries of alternatives and design issues associated with major system components. The objective in this report is to provide background systems level information relating to development and application of cold crucible induction-heated melter technology for radiological waste processing. Included is a detailed description of the bench-top melter system at the V. G. Khlopin Radium Institute currently being used for characterization testing

  20. Application of evolved gas analysis to cold-cap reactions of melter feeds

    Office of Scientific and Technical Information (OSTI)

    for nuclear waste vitrification (Journal Article) | SciTech Connect Application of evolved gas analysis to cold-cap reactions of melter feeds for nuclear waste vitrification Citation Details In-Document Search Title: Application of evolved gas analysis to cold-cap reactions of melter feeds for nuclear waste vitrification In the vitrification of nuclear wastes, the melter feed (a mixture of nuclear waste and glass forming and modifying additives) experiences multiple gas-evolving reactions in

  1. Observation of quad-neutrons and gravity decay during cold fusion

    SciTech Connect (OSTI)

    Matsumoto, T. )

    1991-07-01

    The Nattoh model predicts that neutron nuclei such as quad-neutrons are produced during cold fusion as a result of the emission of a new particle, the iton. Several quad-neutron decays have been successfully recorded on nuclear emulsions. Especially important, micro-explosions caused by gravity decay have been clearly observed. This indicates that gravitational energy as well as fusion energy may be available in cold fusion.

  2. Laboratory's role in Cold War nuclear weapons testing program focus of

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    next 70th anniversary lecture 70th anniversary lecture Laboratory's role in Cold War nuclear weapons testing program focus of next 70th anniversary lecture Lab's role in the development of nuclear weapons during the Cold War period will be discussed by Byron Ristvet of the Defense Threat Reduction Agency. September 5, 2013 This photograph captures the expanding fireball of the world's first full-scale hydrogen bomb test, Ivy-Mike, which was conducted Oct. 31, 1952. This photograph captures

  3. Cold War Films Yield New Effects-Data for U.S. Nuclear Weapons

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Cold War Films Yield New Effects National Security Science Latest Issue:April 2016 past issues All Issues » submit Cold War Films Yield New Effects-Data for U.S. Nuclear Weapons The rush is on to save deteriorating atmospheric nuclear-testing films that give Department of Defense planners, emergency-preparedness officials, and weapons researchers irreplaceable hard data on the yield of nuclear weapons. Digitizing and reanalyzing these films is revealing surprises, causing weapons scientists and

  4. The 2007 Eastern US Spring Freeze: Increased Cold Damage in a Warming World

    Office of Scientific and Technical Information (OSTI)

    (Journal Article) | SciTech Connect The 2007 Eastern US Spring Freeze: Increased Cold Damage in a Warming World Citation Details In-Document Search Title: The 2007 Eastern US Spring Freeze: Increased Cold Damage in a Warming World Plant ecologists have long been concerned with a seemingly paradoxical scenario in the relationship between plant growth and climate change: warming may actually increase the risk of plant frost damage. The underlying hypothesis is that mild winters and warm, early

  5. The temperature dependence of ultra-cold neutron wall losses in material

    Office of Scientific and Technical Information (OSTI)

    bottles coated with deuterated polystryene (Conference) | SciTech Connect The temperature dependence of ultra-cold neutron wall losses in material bottles coated with deuterated polystryene Citation Details In-Document Search Title: The temperature dependence of ultra-cold neutron wall losses in material bottles coated with deuterated polystryene × You are accessing a document from the Department of Energy's (DOE) SciTech Connect. This site is a product of DOE's Office of Scientific and

  6. A light water excess heat reaction suggests that cold fusion may be alkali-hydrogen fusion

    SciTech Connect (OSTI)

    Bush, R.T. )

    1992-09-01

    This paper reports that Mills and Kneizys presented data in support of a light water excess heat reaction obtained with an electrolytic cell highly reminiscent of the Fleischmann-Pons cold fusion cell. The claim of Mills and Kneizys that their excess heat reaction can be explained on the basis of a novel chemistry, which supposedly also explains cold fusion, is rejected in favor of their reaction being, instead, a light water cold fusion reaction. It is the first known light water cold fusion reaction to exhibit excess heat, it may serve as a prototype to expand our understanding of cold fusion. From this new reactions are deduced, including those common to past cold fusion studies. This broader pattern of nuclear reactions is typically seen to involve a fusion of the nuclides of the alkali atoms with the simplest of the alkali-type nuclides, namely, protons, deuterons, and tritons. Thus, the term alkali-hydrogen fusion seems appropriate for this new type of reaction with three subclasses: alkali-hydrogen fusion, alkali-deuterium fusion, and alkali-tritium fusion. A new three-dimensional transmission resonance model (TRM) is sketched. Finally, preliminary experimental evidence in support of the hypothesis of a light water nuclear reaction and alkali-hydrogen fusion is reported. Evidence is presented that appears to strongly implicate the transmission resonance phenomenon of the new TRM.

  7. Mitofusin-2 protects against cold stress-induced cell injury in HEK293 cells

    SciTech Connect (OSTI)

    Zhang, Wenbin; Chen, Yaomin; Yang, Qun; Che, Honglei; Chen, Xiangjun; Yao, Ting; Zhao, Fang; Liu, Mingchao; Ke, Tao; Chen, Jingyuan; Luo, Wenjing

    2010-06-25

    Mitochondrial impairment is hypothesized to contribute to cell injury during cold stress. Mitochondria fission and fusion are closely related in the function of the mitochondria, but the precise mechanisms whereby these processes regulate cell injury during cold stress remain to be determined. HEK293 cells were cultured in a cold environment (4.0 {+-} 0.1 {sup o}C) for 2, 4, 8, or 12 h. Western blot analyses showed that these cells expressed decreased fission-related protein Drp1 and increased fusion-related protein Mfn2 at 4 h; meanwhile, electron microscopy analysis revealed large and long mitochondrial morphology within these cells, indicating increased mitochondrial fusion. With silencing of Mfn2 but not of Mfn1 by siRNA promoted cold-stress-induced cell death with decreased ATP production in HEK293 cells. Our results show that increased expression of Mfn2 and mitochondrial fusion are important for mitochondrial function as well as cell survival during cold stress. These findings have important implications for understanding the mechanisms of mitochondrial fusion and fission in cold-stress-induced cell injury.

  8. Effect of cold work and processing orientation on stress corrosion cracking behavior of alloy 600

    SciTech Connect (OSTI)

    Moshier, W.C.; Brown, C.M.

    2000-03-01

    Cold work accelerates stress corrosion cracking (SCC) growth rates in Alloy 600 (UNS N06600). However, the variation in crack growth rates generated from cold-worked material has been significant, and the effect has been difficult to quantify. A study was performed in hydrogenated water adjusted to pH 10.2 to evaluate systematically the effect of cold work on Alloy 600 as a function of temperature, amount of cold work, stress intensity factor, and processing orientation. Cold work was introduced into the material by tensile prestraining or cold-rolling plate product. Crack growth rates were determined between 252 C and 360 C, stress intensity factors between 21 MPa{radical}m and 55 MPa{radical}m, and yield strengths between 201 MPa and 827 MPa. The material with the highest yield strength was cold-rolled and tested in the longitudinal-transverse (LT) and short-transverse (ST) orientations. Crack growth rates increased with increasing temperature, stress intensity factor, and yield strength. Furthermore, crack growth rates were a strong function of the processing orientation in the cold-rolled plate, with growth rates approximately an order of magnitude greater in the ST orientation compared to the LT orientation. Crack growth rates in the LT orientation were measured between 0.003 x 10{sup {minus}9} m/s and 1.95 x 10{sup {minus}9} m/s and between 0.066 x 10{sup {minus}9} m/s and 6.3 x 10{sup {minus}9} m/s in the ST orientation. Activation energies were slightly greater in the ST orientation, ranging from 154 kcal/mol to 191 kcal/mol, compared to activation energies between 126 kJ/mol and 157 kJ/mol in the LT orientation. Results of this study demonstrated that, although cold work can be used to accelerate SCC, the orientation of crack growth significantly can affect the results and must be taken into account when analyzing data from cold-worked material.

  9. The rhetoric of science: A case study of the cold fusion controversy

    SciTech Connect (OSTI)

    Hatfield, D.L.

    1992-01-01

    This dissertation examines the circumstances surrounding and the rhetoric involved in the cold fusion controversy begun on March 23, 1989, when two University of Utah electrochemists, Martin Fleischmann and Stanley Pons, announced by press conference the discovery of room-temperature nuclear fusion. The dissertation seeks to determine to what extent a rhetorical analysis of cold fusion discourse may increase understanding of the controversy; the success of Fleischmann and Pons as scientific rhetors; the ways in which scientists' attitudes, values, and assumptions manifest themselves in the discourse; and finally, what may be learned about scientific discourse by examining the cold fusion controversy in particular. Examined were Fleischmann and Pon's initial publication announcing the cold fusion discovery in the Journal of Electroanalytical Chemistry; Steven E. Jones's initial publication of his cold fusion discovery and several representative discourse samples from the journal Nature; and Fleischmann and Pons's latest article in the Journal of Fusion Technology. Cold fusion discourse addressed evidential issues, questioning the existence of the cold fusion phenomenon. Several lines of argument were evoked to address this issue, including experimental competence, experimental replication, external consistency, communality, and disinterestedness. Also discovered is division between electrochemists and physicists over what constitutes valid evidence: electrochemists looked to excess heat production as proof of fusion; physicists looked to neutron production. The study concludes that Fleischmann and Pons followed an unsuccessful rhetorical strategy in their initial published paper. An alternative rhetorical strategy was available to Fleischmann and Pons, one in which they could have interpreted their evidence, thereby evoking a less confrontational response from the scientific community.

  10. Critical factors in transitioning from fuel cell to cold fusion technology

    SciTech Connect (OSTI)

    Mcgraw, T.F.; Davis, R.R.

    1998-07-01

    The fuel cell industry possesses much of the required manufacturing equipment and knowledge-base (e.g., proton conduction and hydrogen safety) necessary to develop cold fusion systems. Key factors in making a transition to cold fusion technology are discussed. Loading of reaction material can be provided by electrolytic charging and high gas over-pressure. Effective pressures over 10,000 atmospheres are required in cold fusion systems, giving a loading of H/M = 1; and a combination of loading methods is highly desirable. Systems must be designed to provide continuous flow of hydrogen ions ({much{underscore}gt}10{sup 17}/sec for ten kilowatts), with an input power source of 50 watts (est.). Cold fusion experiments have shown that helium is formed during the reaction, and physical changes occur in the reaction material. These revelations impact design and operation of cold fusion systems, as the reaction material must be replaced periodically, while the systems must maintain integrity during operation. Safety and cost are also highly important considerations.

  11. Design and first cold test of BNL superconducting 112 MHz QWR for electron gun applications

    SciTech Connect (OSTI)

    Belomestnykh, S.; Ben-Zvi, I.; Boulware, C.H.; Chang, X.; Grimm, T.L.; Siegel, B.; Than, R.; Winowski, M.

    2011-03-28

    Brookhaven National Laboratory and Niowave, Inc. have designed, fabricated, and performed the first cold test of a superconducting 112 MHz quarter-wave resonator (QWR) for electron gun experiments. The first cold test of the QWR cryomodule has been completed at Niowave. The paper discusses the cryomodule design, presents the cold test results, and outline plans to upgrade the cryomodule for future experiments. A quarter-wave resonator concept of superconducting RF (SRF) electron gun was proposed at BNL for electron cooling ion/proton beams at RHIC. QWRs can be made sufficiently compact even at low RF frequencies (long wavelengths). The long wavelength allows to produce long electron bunches, thus minimizing space charge effects and enabling high bunch charge. Also, such guns should be suitable for experiments requiring high average current electron beams. A 112 MHz QWR gun was designed, fabricated, and cold-tested in collaboration between BNL and Niowave. This is the lowest frequency SRF gun ever tested successfully. In this paper we describe the gun design and fabrication, present the cold test results, and outline plans for the cryomodule upgrade for future experiments.

  12. SNS 2.1K Cold Box Turn-down Studies

    SciTech Connect (OSTI)

    F. Casagrande; P.A. Gurd; D.R. Hatfield; M.P. Howell; W.H. Strong; D. Arenius; J. Creel; V. Ganni; P. Knudsen

    2006-06-26

    The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is nearing completion. The cold section of the Linac consists of 81 superconducting radio frequency cavities cooled to 2.1K by a 2400 watt cryogenic refrigeration system. The 2.1K cold box consists of four stages of centrifugal compressors with LN2-cooled variable speed electric motors and magnetic bearings. The cryogenic system successfully supported the Linac beam commissioning at both 4.2K and 2.1K and has been fully operational since June 2005. This paper describes the control principles utilized and the experimental results obtained for the SNS cold compressors turn-down capability to about 30% of the design flow, and possible limitation of the frequency dependent power factor of the cold compressor electric motors, which was measured for the first time during commissioning. These results helped to support the operation of the Linac over a very broad and stable cold compressor operating flow range (refrigeration capacity) and pressure. This in turn helped to optimize the cryogenic system operating parameters, minimizing the utilities and improving the system reliability and availability.

  13. SANS study of understanding mechanism of cold gelation of globular proteins

    SciTech Connect (OSTI)

    Chinchalikar, A. J., E-mail: akshayc@barc.gov.in; Kumar, Sugam, E-mail: akshayc@barc.gov.in; Aswal, V. K., E-mail: akshayc@barc.gov.in; Wagh, A. G. [Solid State Physics Division, Bhabha Atomic Research Centre, Mumbai-400085 (India); Kohlbrecher, J. [Laboratory of Neutron Scattering, Paul Scherrer Institut, CH - 5232 PSI Villigen (Switzerland)

    2014-04-24

    Small-angle neutron scattering (SANS) has been used to probe the evolution of interaction and the resultant structures in the cold gelation of globular proteins. The cold gelation involves two steps consisting of irreversible protein deformation by heating followed by some means (e.g. increasing ionic strength) to bring them together at room temperature. We have examined the role of different salts in cold gelation of preheated aqueous Bovine Serum Albumin (BSA) protein solutions. The interactions have been modeled by two Yukawa potential combining short-range attraction and long-range repulsion. We show that in step 1 (preheated temperature effect) the deformation of protein increases the magnitude of attractive interaction but not sufficient to induce gel. The attractive interaction is further enhanced in step 2 (salt effect) to result in gel formation. The salt effect is found to be strongly depending on the valency of the counterions. The gel structure has been characterized by the mass fractals.

  14. Spent nuclear fuel project cold vacuum drying facility vacuum and purge system design description

    SciTech Connect (OSTI)

    IRWIN, J.J.

    1998-11-30

    This document provides the System Design Description (SDD) for the Cold Vacuum Drying Facility (CVDF) Vacuum and Purge System (VPS) . The SDD was developed in conjunction with HNF-SD-SNF-SAR-O02, Safety Analysis Report for the Cold Vacuum Drying Facility, Phase 2, Supporting Installation of Processing Systems (Garvin 1998), The HNF-SD-SNF-DRD-002, 1998, Cold Vacuum Drying Facility Design Requirements, and the CVDF Design Summary Report. The SDD contains general descriptions of the VPS equipment, the system functions, requirements and interfaces. The SDD provides references for design and fabrication details, operation sequences and maintenance. This SDD has been developed for the SNFP Operations Organization and shall be updated, expanded, and revised in accordance with future design, construction and startup phases of the CVDF until the CVDF final ORR is approved.

  15. Cold Climate and Retrofit Applications for Air-to-Air Heat Pumps

    SciTech Connect (OSTI)

    Baxter, Van D

    2015-01-01

    Air source heat pumps (ASHP) including air-to-air ASHPs are easily applied to buildings almost anywhere for new construction as well as retrofits or renovations. They are widespread in milder climate regions but their use in cold regions is hampered due to low heating efficiency and capacity at cold outdoor temperatures. Retrofitting air-to-air ASHPs to existing buildings is relatively easy if the building already has an air distribution system. For buildings without such systems alternative approaches are necessary. Examples are ductless, minisplit heat pumps or central heat pumps coupled to small diameter, high velocity (SDHV) air distribution systems. This article presents two subjects: 1) a summary of R&D investigations aimed at improving the cold weather performance of ASHPs, and 2) a brief discussion of building retrofit options using air-to-air ASHP systems.

  16. The Department of Energy Announces Major Cold War Legacy Waste Cleanup

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Milestone Media Contact: (208) 586-4940 For Immediate Release: September 28, 2011 The Department of Energy Announces Major Cold War Legacy Waste Cleanup Milestone Waste Isolation Pilot Plant Receives 10,000th Shipment CARLSBAD, NM - The U.S. Department of Energy today announced that the Waste Isolation Pilot Plant (WIPP) received its 10,000th shipment of transuranic (TRU) waste over the weekend. This marks an important milestone in DOE�s mission to clean up the country�s Cold War

  17. Singlet particles as cold dark matter in a noncommutative space-time

    SciTech Connect (OSTI)

    Ettefaghi, M. M.

    2009-03-15

    We extend the noncommutative (NC) standard model to incorporate singlet particles as cold dark matter. In the NC space-time, the singlet particles can be coupled to the U(1) gauge field in the adjoint representation. We study the relic density of the singlet particles due to the NC induced interaction. Demanding either the singlet fermion or the singlet scalar to serve as cold dark matter and the NC induced interactions to be relevant to the dark matter production, we obtain the corresponding relations between the NC scale and the dark matter masses, which are consistent with some existing bounds.

  18. Vessel Cold-Ironing Using a Barge Mounted PEM Fuel Cell: Project Scoping

    Energy Savers [EERE]

    and Feasibility | Department of Energy Vessel Cold-Ironing Using a Barge Mounted PEM Fuel Cell: Project Scoping and Feasibility Vessel Cold-Ironing Using a Barge Mounted PEM Fuel Cell: Project Scoping and Feasibility This Sandia National Laboratories study examines the feasibility of a hydrogen-fueled PEM fuel cell barge to provide electrical power to vessels at anchorage or at berth. The study includes both a determination of the technical feasibility of the idea as well as an analysis of

  19. Waste Tank Size Determination for the Hanford River Protection Project Cold Test, Training, and Mockup Facility

    SciTech Connect (OSTI)

    Onishi, Yasuo; Wells, Beric E.; Kuhn, William L.

    2001-03-30

    The objective of the study was to determine the minimum tank size for the Cold Test Facility process testing of Hanford tank waste. This facility would support retrieval of waste in 75-ft-diameter DSTs with mixer pumps and SSTs with fluidic mixers. The cold test model will use full-scale mixer pumps, transfer pumps, and equipment with simulated waste. The study evaluated the acceptability of data for a range of tank diameters and depths and included identifying how the test data would be extrapolated to predict results for a full-size tank.

  20. Probing novel scalar and tensor interactions from (ultra)cold neutrons to

    Office of Scientific and Technical Information (OSTI)

    the LHC (Journal Article) | SciTech Connect Journal Article: Probing novel scalar and tensor interactions from (ultra)cold neutrons to the LHC Citation Details In-Document Search Title: Probing novel scalar and tensor interactions from (ultra)cold neutrons to the LHC Authors: Bhattacharya, Tanmoy ; Cirigliano, Vincenzo ; Cohen, Saul D. ; Filipuzzi, Alberto ; González-Alonso, Martín ; Graesser, Michael L. ; Gupta, Rajan ; Lin, Huey-Wen Publication Date: 2012-03-30 OSTI Identifier: 1098630

  1. DEVELOPMENT OF COLD CLIMATE HEAT PUMP USING TWO-STAGE COMPRESSION

    SciTech Connect (OSTI)

    Shen, Bo; Rice, C Keith; Abdelaziz, Omar; Shrestha, Som S

    2015-01-01

    This paper uses a well-regarded, hardware based heat pump system model to investigate a two-stage economizing cycle for cold climate heat pump applications. The two-stage compression cycle has two variable-speed compressors. The high stage compressor was modelled using a compressor map, and the low stage compressor was experimentally studied using calorimeter testing. A single-stage heat pump system was modelled as the baseline. The system performance predictions are compared between the two-stage and single-stage systems. Special considerations for designing a cold climate heat pump are addressed at both the system and component levels.

  2. Possibility of phase transitions inducing cold fusion in palladium/deuterium systems

    SciTech Connect (OSTI)

    Zhang, W.X. )

    1992-01-01

    In this paper a tentative theory is presented in which {beta}-phase PdD{sub x} containing supersaturated deuterium transits into {beta}-phase PdD{sub x} containing less deuterium and {alpha}-phase PdD{sub x}. High-pressure ({approx}10 GPa) deuterium bubbles form at the same time. As the bubbles release energy, cracks are created in the PdD{sub x} crystal, and charge separation of deuterium occurs. Thus would cold fusion be induced. This proposal supports the fracture mechanism for cold fusion.

  3. Stationary self-focusing of intense laser beam in cold quantum plasma using ramp density profile

    SciTech Connect (OSTI)

    Habibi, M.; Ghamari, F.

    2012-10-15

    By using a transient density profile, we have demonstrated stationary self-focusing of an electromagnetic Gaussian beam in cold quantum plasma. The paper is devoted to the prospects of using upward increasing ramp density profile of an inhomogeneous nonlinear medium with quantum effects in self-focusing mechanism of high intense laser beam. We have found that the upward ramp density profile in addition to quantum effects causes much higher oscillation and better focusing of laser beam in cold quantum plasma in comparison to that in the classical relativistic case. Our computational results reveal the importance and influence of formation of electron density profiles in enhancing laser self-focusing.

  4. Method and apparatus for regenerating cold traps within liquid-metal systems

    DOE Patents [OSTI]

    McKee, Jr., John M.

    1976-01-01

    Oxide and hydride impurities of a liquid metal such as sodium are removed from a cold trap by heating to a temperature at which the metal hydroxide is stable in a molten state. The partial pressure of hydrogen within the system is measured to determine if excess hydride or oxide is present. Excess hydride is removed by venting hydrogen gas while excess oxide can be converted to molten hydroxide through the addition of hydrogen. The resulting, molten hydroxide is drained from the trap which is then returned to service at cold trap temperatures within the liquid-metal system.

  5. Advanced Composite Materials for Cold and Cryogenic Hydrogen Storage Applications in Fuel Cell Electric Vehicles Workshop

    Broader source: Energy.gov [DOE]

    Agenda and presentations from the Advanced Composite Materials for Cold and Cryogenic Hydrogen Storage Applications in Fuel Cell Electric Vehicles Workshop hosted by the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy's Fuel Cell Technologies Office and Pacific Northwest National Laboratory in Dallas, Texas, on October 29, 2015.

  6. Compact cold stage for micro-computerized tomography imaging of chilled or frozen samples

    SciTech Connect (OSTI)

    Hullar, Ted; Anastasio, Cort; Paige, David F.; Rowland, Douglas J.

    2014-04-15

    High resolution X-ray microCT (computerized tomography) can be used to image a variety of objects, including temperature-sensitive materials. In cases where the sample must be chilled or frozen to maintain sample integrity, either the microCT machine itself must be placed in a refrigerated chamber, or a relatively expensive commercial cold stage must be purchased. We describe here the design and construction of a low-cost custom cold stage suitable for use in a microCT imaging system. Our device uses a boron nitride sample holder, two-stage Peltier cooler, fan-cooled heat sink, and electronic controller to maintain sample temperatures as low as ?25?C 0.2?C for the duration of a tomography acquisition. The design does not require modification to the microCT machine, and is easily installed and removed. Our custom cold stage represents a cost-effective solution for refrigerating CT samples for imaging, and is especially useful for shared equipment or machines unsuitable for cold room use.

  7. Advanced Vehicle Testing Activity Cold Weather On-road Testing of the Chevrolet Volt

    SciTech Connect (OSTI)

    Smart, John

    2015-03-01

    This report details cold weather on-road testing of a Chevrolet Volt. It quantifies changes in efficiency and electric range as ambient temperature changes. It will be published to INL's AVTA website as an INL technical report and will be accessible to the general public.

  8. Field Performance of Inverter-Driven Heat Pumps in Cold Climates

    SciTech Connect (OSTI)

    Williamson, James; Aldrich, Robb

    2015-08-19

    Traditionally, air-source heat pumps (ASHPs) have been used more often in warmer climates; however, some new ASHPs are gaining ground in colder areas. These systems operate at subzero (Fahrenheit) temperatures and many do not include backup electric resistance elements. There are still uncertainties, however, about capacity and efficiency in cold weather. Also, questions such as “how cold is too cold?” do not have clear answers. These uncertainties could lead to skepticism among homeowners; poor energy savings estimates; suboptimal system selection by heating, ventilating, and air-conditioning contractors; and inconsistent energy modeling. In an effort to better understand and characterize the heating performance of these units in cold climates, the U.S. Department of Energy Building America team, Consortium for Advanced Residential Buildings (CARB), monitored seven inverter-driven, ductless ASHPs across the Northeast. Operating data were collected for three Mitsubishi FE18 units, three Mitsubishi FE12 units, and one Fujitsu 15RLS2 unit. The intent of this research was to assess heat output, electricity consumption, and coefficients of performance (COPs) at various temperatures and load conditions. This assessment was accomplished with long- and short-term tests that measured power consumption; supply, return, and outdoor air temperatures; and airflow through the indoor fan coil.

  9. Performance evaluation approach for the supercritical helium cold circulators of ITER

    SciTech Connect (OSTI)

    Vaghela, H.; Sarkar, B.; Bhattacharya, R.; Kapoor, H. [ITER-India, Institute for Plasma Research, Near Indira Bridge, Bhat, Gandhinagar-382428 (India); Chalifour, M.; Chang, H.-S.; Serio, L. [ITER Organization, Route de Vinon sur Verdon - 13115 St Paul Lez Durance (France)

    2014-01-29

    The ITER project design foresees Supercritical Helium (SHe) forced flow cooling for the main cryogenic components, namely, the superconducting (SC) magnets and cryopumps (CP). Therefore, cold circulators have been selected to provide the required SHe mass flow rate to cope with specific operating conditions and technical requirements. Considering the availability impacts of such machines, it has been decided to perform evaluation tests of the cold circulators at operating conditions prior to the series production in order to minimize the project technical risks. A proposal has been conceptualized, evaluated and simulated to perform representative tests of the full scale SHe cold circulators. The objectives of the performance tests include the validation of normal operating condition, transient and off-design operating modes as well as the efficiency measurement. A suitable process and instrumentation diagram of the test valve box (TVB) has been developed to implement the tests at the required thermodynamic conditions. The conceptual engineering design of the TVB has been developed along with the required thermal analysis for the normal operating conditions to support the performance evaluation of the SHe cold circulator.

  10. Design and Analyisi of a Self-centered Cold Mass Support for the MICE Coupling Magnet

    SciTech Connect (OSTI)

    Wang, Li; Pan, Heng; Wu, Hong; Li, S. Y.; Guo, Xing Long; Zheng, Shi Xian; Green, Michael A.

    2011-05-04

    The Muon Ionization Cooling Experiment (MICE) consists of eighteen superconducting solenoid coils in seven modules, which are magnetically hooked together since there is no iron to shield the coils and the return flux. The RF coupling coil (RFCC) module consists of a superconducting coupling solenoid mounted around four conventional conducting 201.25 MHz closed RF cavities. The coupling coil will produce up to a 2.2 T magnetic field on the centerline to keep the beam within the RF cavities. The peak magnetic force on the coupling magnet from other magnets in MICE is up to 500 kN in longitudinal direction, which will be transferred to the base of the RF coupling coil (RFCC) module through a cold mass support system. A self-centered double-band cold mass support system with intermediate thermal interruption is applied to the coupling magnet, and the design is introduced in detail in this paper. The thermal and structural analysis on the cold mass support assembly has been carried out using ANSYS. The present design of the cold mass support can satisfy with the stringent requirements for the magnet center and axis azimuthal angle at 4.2 K and fully charged.

  11. Numerical Studies of Collective Phenomena in Two-Dimensional Electron and Cold Atom Systems

    SciTech Connect (OSTI)

    Rezayi, Edward

    2013-07-25

    Numerical calculations were carried out to investigate a number of outstanding questions in both two-dimensional electron and cold atom systems. These projects aimed to increase our understanding of the properties of and prospects for non-Abelian states in quantum Hall matter.

  12. Cold-Air-Pool Structure and Evolution in a Mountain Basin: Peter Sinks, Utah

    SciTech Connect (OSTI)

    Clements, Craig B.; Whiteman, Charles D.; Horel, John D.

    2003-06-01

    The evolution of potential temperature and wind structure during the buildup of nocturnal cold-air pools was investigated during clear, dry, September nights in Utah's Peter Sinks basin, a 1-km-diameter limestone sinkhole that holds the Utah minimum temperature record of -56 C. The evolution of cold-pool characteristics depended on the strength of prevailing flows above the basin. On an undisturbed day, a 30 C diurnal temperature range and a strong nocturnal potential temperature inversion (22 K in 100 m) were observed in the basin. Initially, downslope flows formed on the basin sidewalls. As a very strong potential temperature jump (17 K) developed at the top of the cold pool, however, the winds died within the basin and over the sidewalls. A persistent turbulent sublayer formed below the jump. Turbulent sensible heat flux on the basin floor became negligible shortly after sunset while the basin atmosphere continued to cool. Temperatures over the slopes, except for a 1 to 2-m-deep layer, became warmer than over the basin center at the same altitude. Cooling rates for the entire basin near sunset were comparable to the 90 W m-2 rate of loss of net longwave radiation at the basin floor, but these rates decreased to only a few watts per square meter by sunrise. This paper compares the observed cold-pool buildup in basins with inversion buildup in valleys.

  13. Highlights of papers presented at the workshop on cold fusion phenomena

    SciTech Connect (OSTI)

    Not Available

    1989-09-01

    This report contains highlights of formal oral papers presented at the Workshop on Cold Fusion Phenomena, hosted by Los Alamos National Laboratory and held May 23--25, 1989, in Santa Fe, New Mexico. General topics covered are: physics of fusion reactions; neutron and gamma-ray spectroscopy; colorimetry; and applicable condensed-matter physics, electrochemistry, and analytical chemistry.

  14. A proposal for a cold fusion study in the Ti/D system

    SciTech Connect (OSTI)

    Tian, Z.A. )

    1992-01-01

    In this paper, to enhance the cold fusion process in the Ti/D system, a special experimental procedure is proposed that includes electrolysis in nonaqueous solutions at low temperature (about {minus}70{degrees} C), surface pretreatment by depositing nickel film on titanium electrodes, and a unique triggering method based on passing current axially through the electrode wire.

  15. Idaho Site’s Cold War Cleanup Takes Center Stage in Publication

    Broader source: Energy.gov [DOE]

    IDAHO FALLS, Idaho – An association with more than 29,000 members featured an in-depth article on EM’s extensive Cold War legacy cleanup at the Idaho site in the current issue of its publication, The Military Engineer.

  16. Accelerator-based neutron source using a cold deuterium target with degenerate electrons

    SciTech Connect (OSTI)

    Phillips, R. E.; Ordonez, C. A. [Department of Physics, University of North Texas, Denton, Texas 76203 (United States)] [Department of Physics, University of North Texas, Denton, Texas 76203 (United States)

    2013-07-15

    A neutron generator is considered in which a beam of tritons is incident on a hypothetical cold deuterium target with degenerate electrons. The energy efficiency of neutron generation is found to increase substantially with electron density. Recent reports of potential targets are discussed.

  17. Cold starting capabilities of petroleum and syntehetic lubricants in heavy-duty diesel engines

    SciTech Connect (OSTI)

    Margeson, M.A.; Belmesch, B.J. )

    1989-01-01

    The objective of the work described in this paper was to compare the cold weather starting ability of diesel engines lubricated with SAE 15W-40 petroleum and SAE 5W-30 synthetic motor oil. Laboratory bench tests were used to compare rhelogical features such as borderline pumping temperature and cold cranking simulator profiles. A cold box provided a well controlled environment in which cranking and starting studies were carried out on the two oils in a turbocharged diesel engine. The SAE 5W-30 synthetic exhibited higher cranking speeds, lower starter amperage draw and immediate oil pressure readings when compared to the SAE l5W-40 petroleum. The SAE 5W-30 synthetic oil was safely started at {minus} l0 {sup 0}F oil temperature without auxiliary heaters. The comparative cylinder turbocharged diesel engines representing conditions commonly found in the commercial and off-highway sectors, These studies indicate that combining high capacity cold cranking amperage batteries, high pressure ether aid injection, and SAE 5W-30 synthetic oil resulted in a system that safely starts diesel engines down to actual oil temperatures of at least {minus} 10 {sup 0}F.

  18. Compact, Light-Weight, Single-Phase, Liquid-Cooled Cold Plate | Department

    Broader source: Energy.gov (indexed) [DOE]

    of Energy 2 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting PDF icon ape039_narumanchi_2012_o.pdf More Documents & Publications Advanced Liquid Cooling R&D Compact, Light-Weight, Single-Phase, Liquid-Cooled Cold Plate

  19. Compact, Light-Weight, Single-Phase, Liquid-Cooled Cold Plate | Department

    Broader source: Energy.gov (indexed) [DOE]

    of Energy ape039_narumanchi_2011_p.pdf More Documents & Publications Compact, Light-Weight, Single-Phase, Liquid-Cooled Cold Plate Advanced Liquid Cooling R&D Air Cooling Technology for Power Electronic Thermal Control

  20. Mechanisms of Convective Cloud Organization by Cold Pools over Tropical Warm Ocean during the AMIE/DYNAMO Field Campaign

    SciTech Connect (OSTI)

    Feng, Zhe; Hagos, Samson M.; Rowe, Angela; Burleyson, Casey D.; Martini, Matus; de Szoeke, S.

    2015-06-01

    This paper investigates the mechanisms of convective cloud organization by precipitation-driven cold pools over the warm tropical Indian Ocean during the 2011 Atmospheric Radiation Measurement (ARM) Madden-Julian Oscillation (MJO) Investigation Experiment / Dynamics of the MJO (AMIE/DYNAMO) field campaign. A high-resolution regional model simulation is performed using the Weather Research and Forecasting model during the transition from suppressed to active phases of the November 2011 MJO. The simulated cold pool lifetimes, spatial extent and thermodynamic properties agree well with the radar and ship-borne observations from the field campaign. The thermodynamic and dynamic structures of the outflow boundaries of isolated and intersecting cold pools in the simulation and the associated secondary cloud populations are examined. Intersecting cold pools last more than twice as long, are twice as large, 41% more intense (measured by buoyancy), and 62% deeper than isolated cold pools. Consequently, intersecting cold pools trigger 73% more convective clouds than isolated ones. This is possibly due to stronger outflows that enhance secondary updraft velocities by up to 45%. However, cold pool-triggered convective clouds grow into deep convection not because of the stronger secondary updrafts at cloud base, but rather due to closer spacing (aggregation) between clouds and larger cloud clusters that formed along the cold pool boundaries when they intersect. The close spacing of large clouds moistens the local environment and reduces entrainment drying, allowing the clouds to further develop into deep convection. Implications to the design of future convective parameterization with cold pool-modulated entrainment rates are discussed.

  1. Effect of cold work on the growth rates of stress corrosion cracks in structural materials of nuclear systems

    SciTech Connect (OSTI)

    Magdowski, R.; Speidel, M.O.

    1996-10-01

    The growth rates of stress corrosion cracks in austenitic stainless steels and nickel base alloy 600 exposed to simulated boiling water reactor coolant were measured by fracture mechanics testing techniques. Cold work may increase the crack growth rates up to one hundred times. In both, the annealed condition and the cold worked condition, the stress corrosion crack growth rates are independent of stress intensity over a wide K-range and crack growth rates correlate well with yield strength and hardness. In the annealed condition the fracture path is intergranular, but higher degrees of cold work introduce higher proportions of transgranular stress corrosion cracking.

  2. Cold Crucible Induction Melting Technology for Vitrification of High Level Waste: Development and Status in India

    SciTech Connect (OSTI)

    Sugilal, G.; Sengar, P.B.S. [Nuclear Recycle Group, Bhabha Atomic Research Centre, Trombay, Mumbai (India)

    2008-07-01

    Cold crucible induction melting is globally emerging as an alternative technology for the vitrification of high level radioactive waste. The new technology offers several advantages such as high temperature availability with long melter life, high waste loading, high specific capacity etc. Based on the laboratory and bench scale studies, an engineering scale cold crucible induction melter was locally developed in India. The melter was operated continuously to assess its performance. The electrical and thermal efficiencies were found to be in the range of 70-80 % and 10-20 % respectively. Glass melting capacities up to 200 kg m{sup -2} hr{sup -1} were accomplished using the ESCCIM. Industrially adaptable melter operating procedures for start-up, melting and pouring operations were established (author)

  3. The Helium Cooling System and Cold Mass Support System for theMICE Coupling Solenoid

    SciTech Connect (OSTI)

    Wang, L.; Wu, H.; Li, L.K.; Green, M.A.; Liu, C.S.; Li, L.Y.; Jia, L.X.; Virostek, S.P.

    2007-08-27

    The MICE cooling channel consists of alternating threeabsorber focus coil module (AFC) and two RF coupling coil module (RFCC)where the process of muon cooling and reacceleration occurs. The RFCCmodule comprises a superconducting coupling solenoid mounted around fourconventional conducting 201.25 MHz closed RF cavities and producing up to2.2T magnetic field on the centerline. The coupling coil magnetic fieldis to produce a low muon beam beta function in order to keep the beamwithin the RF cavities. The magnet is to be built using commercialniobium titanium MRI conductors and cooled by pulse tube coolers thatproduce 1.5 W of cooling capacity at 4.2 K each. A self-centering supportsystem is applied for the coupling magnet cold mass support, which isdesigned to carry a longitudinal force up to 500 kN. This report willdescribe the updated design for the MICE coupling magnet. The cold masssupport system and helium cooling system are discussed indetail.

  4. Mathematical Model of Cold CapPreliminary One-Dimensional Model Development

    SciTech Connect (OSTI)

    Pokorny, Richard; Hrma, Pavel R.

    2011-03-25

    The ultimate goal of batch-melting studies, laboratory-scale, large-scale, or mathematical modeling is to increase the rate of glass processing in an energy-efficient manner. Mathematical models are not merely an intermediate step between laboratory-scale and large-scale studies, but are also an important tool for assessing the responses of melters to vast combinations of process parameters. In the simplest melting situation considered in this study, a cold cap of uniform thickness rests on a pool of molten glass from which it receives a steady uniform heat flux. Thus, as the feed-to-glass conversion proceeds, the temperature, velocity, and extent of feed reactions are functions of the position along the vertical coordinate, and these functions do not vary with time. This model is used for the sensitivity analyses on the effects of key parameters on the cold-cap behavior.

  5. The surfdyn concept: An attempt to solve (or rename) the puzzles of cold nuclear fusion

    SciTech Connect (OSTI)

    Glueck, P. )

    1993-08-01

    The lack of reproducibility of the cold fusion experiments, aggravated by the great diversity and inconsistency of the positive results, implies that these nuclear phenomena are hypersensitive, i.e., correlated to a [open quotes]chaotic[close quotes] factor. All the factors considered so far, such as structure, transformations, or defects of the crystal lattice; bubbles of deuterium; dendrites, etc., are insufficiently chaotic to explain the known facts. Experimental data suggest that nuclear reactions take place in active sites on the surface of the lattice, that they are stimulated by dynamics factors, and that they represent an extreme form of heterogeneous catalysis. Consequently, according to modern ideas concerning catalysis, the desired chaotic factor is the surface dynamics of some metallic deuterides (hydrides). This hypothesis, called the surfdyn concept, is compatible with all published data, explains the peculiarities of cold fusion, and must be supported by an adequate theory describing the nature and mechanisms of the different nuclear processes. 44 refs.

  6. Cross sections calculated for cold fusion reactions for producing superheavy nuclei

    SciTech Connect (OSTI)

    Smolanczuk, Robert

    2008-08-15

    We propose a handy formula for calculating the formation cross sections for optimal bombarding energies for transactinides (superheavy elements). By means of the proposed formula the cross sections for asymmetric and symmetric cold fusion reactions (one-neutron-out reactions) are calculated. The fusion barrier and its position are calculated by using the folding heavy-ion potential that for spherical reaction partners has the form of a seventh-order polynomial of the radial coordinate with built-in dependence on the thickness of the nuclear surface, as well as on the separation energy of the least bound nucleon. Possibilities of further experimental exploitation of cold fusion in producing the superheavy nuclei are briefly discussed.

  7. Nuclear reaction products that would appear if substantial cold fusion occurred

    SciTech Connect (OSTI)

    Mueller, D.; Grisham, L.R. . Plasma Physics Lab.)

    1989-11-01

    This paper reports on recent claims of net energy production by cold fusion that have prompted an examination of all the positive Q value, two-body nuclear reactions that might result from the fusion of any of the isotopes in the apparatus used by Fleischmann and Pons. Any energy production that may result from cold fusion would be accompanied by copious production of nuclear reaction products (on the order of 10{sup 13}/s). Furthermore, the elementary properties of the alpha particle at the deuteron + deuteron threshold are discussed. An important property of the alpha at this high excitation is its nearly prompt (10{sup {minus}20} s) decay by particle emission to {sup 3}He + n or triton + proton.

  8. Electromagnetic field of a charge intersecting a cold plasma boundary in a waveguide

    SciTech Connect (OSTI)

    Alekhina, Tatiana Yu.; Tyukhtin, Andrey V.

    2011-06-15

    We analyze the electromagnetic field of a charge crossing a boundary between a vacuum and cold plasma in a waveguide. We obtain exact expressions for the field components and the spectral density of the transition radiation. With the steepest descent technique, we investigate the field components. We show that the electromagnetic field has a different structure in a vacuum than in cold plasma. We also develop an algorithm for the computation of the field based on a certain transformation of the integration path. The behavior of the field depending on distance and time and the spectral density depending on frequency are explored for different charge velocities. Some important physical effects are noted. A considerable increase and concentration of the field near the wave front in the plasma is observed for the case of ultrarelativistic particles. In the plasma, the mode envelopes and spectral density show zero points when the charge velocity is within certain limits.

  9. Nonlinear oscillations and waves in an arbitrary mass ratio cold plasma

    SciTech Connect (OSTI)

    Verma, Prabal Singh

    2011-12-15

    It is well known that nonlinear standing oscillations in an arbitrary mass ratio cold plasma always phase mix away. However, there exist nonlinear electron-ion traveling wave solutions, which do not exhibit phase mixing because they have zero ponderomotive force. The existence of these waves has been demonstrated using a perturbation method. Moreover, it is shown that cold plasma BGK waves [Albritton et al., Nucl. Fusion 15, 1199 (1975)] phase mix away if ions are allowed to move and the scaling of phase mixing is found to be different from earlier work [Sengupta et al., Phys. Rev. Lett. 82, 1867 (1999)]. Phase mixing of these waves has been further verified in 1-D particle in cell simulation.

  10. Mathematical modeling of cold cap: Effect of bubbling on melting rate

    SciTech Connect (OSTI)

    Pokorny, Richard; Kruger, Albert A.; Hrma, Pavel R.

    2014-12-31

    The rate of melting is a primary concern in the vitrification of radioactive wastes because it directly influences the life cycle of nuclear waste cleanup efforts. To increase glass melting performance, experimental and industrial all-electric waste glass melters employ various melt-rate enhancement techniques, the most prominent being the application of bubblers submerged into molten glass. This study investigates various ways in which bubbling affects melting rate in a waste glass melter. Using the recently developed cold cap model, we suggest that forced convection of molten glass, which increases the cold cap bottom temperature, is the main factor. Other effects, such as stirring the feed into molten glass or reducing the insulating effect of foaming, also play a role.

  11. The new Cold Neutron Chopper Spectrometer at the Spallation Neutron Source -- Design and Performance

    SciTech Connect (OSTI)

    Ehlers, Georg; Podlesnyak, Andrey A.; Niedziela, Jennifer L.; Iverson, Erik B.; Sokol, Paul E.

    2011-01-01

    The design and performance of the new cold neutron chopper spectrometer (CNCS) at the Spallation Neutron Source in Oak Ridge are described. CNCS is a direct-geometry inelastic time-of-flight spectrometer, designed essentially to cover the same energy and momentum transfer ranges as IN5 at ILL, LET at ISIS, DCS at NIST, TOFTOF at FRM-II, AMATERAS at J-PARC, PHAROS at LANSCE, and NEAT at HZB, at similar energy resolution. Measured values of key figures such as neutron flux at sample position and energy resolution are compared between measurements and ray tracing Monte Carlo simulations, and good agreement (better than 20% of absolute numbers) has been achieved. The instrument performs very well in the cold and thermal neutron energy ranges, and promises to become a workhorse for the neutron scattering community for quasielastic and inelastic scattering experiments.

  12. The new cold neutron chopper spectrometer at the Spallation Neutron Source: Design and performance

    SciTech Connect (OSTI)

    Ehlers, G.; Podlesnyak, A. A.; Niedziela, J. L.; Iverson, E. B.; Sokol, P. E.

    2011-08-15

    The design and performance of the new cold neutron chopper spectrometer (CNCS) at the Spallation Neutron Source in Oak Ridge are described. CNCS is a direct-geometry inelastic time-of-flight spectrometer, designed essentially to cover the same energy and momentum transfer ranges as IN5 at ILL, LET at ISIS, DCS at NIST, TOFTOF at FRM-II, AMATERAS at J-PARC, PHAROS at LANSCE, and NEAT at HZB, at similar energy resolution. Measured values of key figures such as neutron flux at sample position and energy resolution are compared between measurements and ray tracing Monte Carlo simulations, and good agreement (better than 20% of absolute numbers) has been achieved. The instrument performs very well in the cold and thermal neutron energy ranges, and promises to become a workhorse for the neutron scattering community for quasielastic and inelastic scattering experiments.

  13. A mean field theory for the cold quark gluon plasma applied to stellar structure

    SciTech Connect (OSTI)

    Fogaca, D. A.; Navarra, F. S.; Franzon, B.; Horvath, J. E.

    2013-03-25

    An equation of state based on a mean-field approximation of QCD is used to describe the cold quark gluon plasma and also to study the structure of compact stars. We obtain stellar masses compatible with the pulsar PSR J1614-2230 that was determined to have a mass of (1.97 {+-} 0.04 M{sub Circled-Dot-Operator }), and the corresponding radius around 10-11 km.

  14. Nonaqueous composition for slip casting or cold forming refractory material into solid shapes

    SciTech Connect (OSTI)

    Montgomery, L.C.

    1993-08-24

    A composition is described for slip casting or cold forming non-oxide refractory material(s) into solid shape comprising finely divided solid refractory materials selected from the group consisting of metal boride, refractory carbide, nitride, silicide and a refractory metal of tungsten, molybdenum, tantalum and chromium suspended in a nonaqueous liquid slip composition consisting essentially of a deflocculent composed of a vinyl chloride-vinyl acetate resin dissolved in an organic solvent.

  15. THE LOCAL LEO COLD CLOUD AND NEW LIMITS ON A LOCAL HOT BUBBLE

    SciTech Connect (OSTI)

    Peek, J. E. G.; Heiles, Carl; Peek, Kathryn M. G.; Meyer, David M.; Lauroesch, J. T.

    2011-07-10

    We present a multi-wavelength study of the local Leo cold cloud (LLCC), a very nearby, very cold cloud in the interstellar medium (ISM). Through stellar absorption studies we find that the LLCC is between 11.3 pc and 24.3 pc away, making it the closest known cold neutral medium cloud and well within the boundaries of the local cavity. Observations of the cloud in the 21 cm H I line reveal that the LLCC is very cold, with temperatures ranging from 15 K to 30 K, and is best fit with a model composed of two colliding components. The cloud has associated 100 {mu}m thermal dust emission, pointing to a somewhat low dust-to-gas ratio of 48 x10{sup -22} MJy sr{sup -1} cm{sup 2}. We find that the LLCC is too far away to be generated by the collision among the nearby complex of local interstellar clouds but that the small relative velocities indicate that the LLCC is somehow related to these clouds. We use the LLCC to conduct a shadowing experiment in 1/4 keV X-rays, allowing us to differentiate between different possible origins for the observed soft X-ray background (SXRB). We find that a local hot bubble model alone cannot account for the low-latitude SXRB, but that isotropic emission from solar wind charge exchange (SWCX) does reproduce our data. In a combined local hot bubble and SWCX scenario, we rule out emission from a local hot bubble with an 1/4 keV emissivity greater than 1.1 Snowdens pc{sup -1} at 3{sigma}, four times lower than previous estimates. This result dramatically changes our perspective on our local ISM.

  16. Effect of charge polarization on the Coulomb barrier for cold-fusion reactions

    SciTech Connect (OSTI)

    Ichikawa, Takatoshi; Iwamoto, Akira

    2005-06-01

    We estimate the decrease of the Coulomb-barrier height between colliding partners due to charge polarizations in the entrance channel for cold-fusion reactions. The resulting charge displacements between protons and neutrons are the sum of the surface- and volume-charge components. We show the difference between the charge polarization of light and heavy nuclei and the decrease of the Coulomb barrier height for synthesizing superheavy elements.

  17. Cathode cooling by expansion of hydrogen in calorimetric tests for cold fusion

    SciTech Connect (OSTI)

    Gammon, B.E. )

    1993-05-01

    Expansion of hydrogen and its isotopes from hydrogen-absorbing cathodes can transfer significant amounts of energy to the surrounding aqueous media. In calorimetric efforts to confirm cold fusion, allowance must be made for thermal conduction along electrical leads. In conjunction with consideration of the extent of cathode cooling by expansion of hydrogen, the rupturing of the cavities within the cathodes and limitations to charging of the electrode by hydrogen flowing from fresh cracks are briefly addressed. 11 refs., 1 tab.

  18. Synthesis of transactinide nuclei in cold fusion reactions using radioactive beams

    SciTech Connect (OSTI)

    Smolanczuk, Robert

    2010-06-15

    Chances of synthesis of transactinide nuclei in cold fusion reactions (one-neutron-out reactions) using radioactive beams are evaluated. Because in most of the cases intensities of radioactive beams are significantly less than those of the stable beams, reactions with the greatest radioactive-beam intensities for the particular elements are considered. The results are compared with the recent ones obtained by Loveland [Phys. Rev. C 76, 014612 (2007)], who investigated the same nuclei.

  19. Observation of gravity decays of multiple-neutron nuclei during cold fusion

    SciTech Connect (OSTI)

    Matsumoto, T. . Dept. of Nuclear Engineering)

    1992-08-01

    The Nattoh model predicted that multiple-neutron nuclei such as quad-neutrons can be produced during cold fusion, and the gravity decays of the quad-neutrons were recorded on nuclear emulsions. Several different traces that might be produced by the gravity decays of di-neutron and multiple-neutron nuclei have been successfully observed. The mechanisms of the production of multiple-neutron nuclei are discussed in this paper.

  20. A reassessment of surface friction model for maximum cold fusion reactions in superheavy mass region

    SciTech Connect (OSTI)

    Fukushima, A.; Wada, T.; Ohta, M.; Nasirov, A.; Aritomo, Y.

    2007-02-26

    We have made a study on the capture process of 40,48Ca+ 208Pb systems with a dynamical approach based on the surface friction model. The deformation of the nuclei due to the mutual excitation is taken into account. We have calculated the capture cross sections for several values of the friction coefficients. It was shown that, in the cold fusion reactions, the friction parameters of the surface friction model needs to be reexamined.

  1. Cold fusion: Electrolytic processes. (Latest citations from the Inspec database). Published Search

    SciTech Connect (OSTI)

    1996-06-01

    The bibliography contains citations concerning the production of excess heat during the electrolysis of heavy water, known as cold fusion. Citations cover the design of electrolytic cells, cathode materials, and experimental conditions required to produce excess heat. Neutron emission and detection, calorimetry, and crystallography of the electrodes are discussed. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  2. Using a cold radiometer to measure heat loads and survey heat leaks

    SciTech Connect (OSTI)

    DiPirro, M.; Tuttle, J.; Hait, T.; Shirron, P.

    2014-01-29

    We have developed an inexpensive cold radiometer for use in thermal/vacuum chambers to measure heat loads, characterize emissivity and specularity of surfaces and to survey areas to evaluate stray heat loads. We report here the results of two such tests for the James Webb Space Telescope to measure heat loads and effective emissivities of 2 major pieces of optical ground support equipment that will be used in upcoming thermal vacuum testing of the Telescope.

  3. Space Chamber Reaches Cold Target at Unprecedented Efficiency | U.S. DOE

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Office of Science (SC) Space Chamber Reaches Cold Target at Unprecedented Efficiency Nuclear Physics (NP) NP Home About Research Facilities Science Highlights Benefits of NP Funding Opportunities Nuclear Science Advisory Committee (NSAC) Community Resources Contact Information Nuclear Physics U.S. Department of Energy SC-26/Germantown Building 1000 Independence Ave., SW Washington, DC 20585 P: (301) 903-3613 F: (301) 903-3833 E: Email Us More Information » 10.01.12 Space Chamber Reaches

  4. Cold box shuttle - a system for the recovery of offshore gas - applied to Sweden

    SciTech Connect (OSTI)

    Smith, D.; Eriksson, L.; Pehrsson, L.O.; Strom-Olsen, H.

    1982-01-01

    The recovery of offshore gas as LNG, by heat exchange on an LNG carrier with liquid nitrogen, was studied in the context of a North Sea gas source and a Swedish market. The technical suitability of each component of this cold-box shuttle system was examined and the capital and operating costs were estimated. It was concluded that the system is technically robust and flexible and that, for the case studied, gas could be landed at a competitive cost.

  5. Process Simulation of Cold Pressing and Sintering of Armstrong CP-Ti Powders

    SciTech Connect (OSTI)

    Gorti, Sarma B; Sabau, Adrian S; Peter, William H; Nunn, Stephen D; Yamamoto, Yukinori; Chen, Wei

    2011-01-01

    A computational methodology is presented for the process simulation of cold pressing and sintering of Armstrong CP-Ti powders. Since the powder consolidation is governed by specific pressure-dependent constitutive equations, solution algorithms were developed for the ABAQUS user material subroutine, UMAT, for computing the plastic strain increments based on an implicit integration of the nonlinear yield function, flow rule, and hardening equations. Sintering was simulated using a model based on diffusional creep using the user subroutine CREEP. The initial mesh, stress, and density for the simulation of sintering were obtained from the results of the cold pressing simulation, minimizing the errors from decoupling the cold pressing and sintering simulations. Numerical simulation results are presented for the cold compaction followed by a sintering step of the Ti powders. The numerical simulation results for the relative density were compared to those measured from experiments before and after sintering, showing that the relative density can be accurately predicted. Notice: This manuscript has been authored by UT-Battelle, LLC, under Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy. The United States Government retains and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce the published form of this manuscript, or allow others to do so, for United States Government purposes. ACKNOWLEDGEMENTS This research was sponsored by the U.S. DOE, and carried out at ORNL, under Contract DE-AC05-00OR22725 with UT-Battelle, LLC. This research was sponsored by the U.S. DOE, EERE Industrial Technology Program Office under CPS Agreement # 17881.

  6. OTEC cold water pipe design for problems caused by vortex-excited oscillations

    SciTech Connect (OSTI)

    Griffin, O. M.

    1980-03-14

    Vortex-excited oscillations of marine structures result in reduced fatigue life, large hydrodynamic forces and induced stresses, and sometimes lead to structural damage and to diestructive failures. The cold water pipe of an OTEC plant is nominally a bluff, flexible cylinder with a large aspect ratio (L/D = length/diameter), and is likely to be susceptible to resonant vortex-excited oscillations. The objective of this report is to survey recent results pertaining to the vortex-excited oscillations of structures in general and to consider the application of these findings to the design of the OTEC cold water pipe. Practical design calculations are given as examples throughout the various sections of the report. This report is limited in scope to the problems of vortex shedding from bluff, flexible structures in steady currents and the resulting vortex-excited oscillations. The effects of flow non-uniformities, surface roughness of the cylinder, and inclination to the incident flow are considered in addition to the case of a smooth cyliner in a uniform stream. Emphasis is placed upon design procedures, hydrodynamic coefficients applicable in practice, and the specification of structural response parameters relevant to the OTEC cold water pipe. There are important problems associated with in shedding of vortices from cylinders in waves and from the combined action of waves and currents, but these complex fluid/structure interactions are not considered in this report.

  7. The pinch of cold ions from recycling in the tokamak edge pedestal

    SciTech Connect (OSTI)

    Wan Weigang; Parker, Scott E.; Chen Yang; Park, Gun-Young; Chang, Choong-Seock; Stotler, Daren

    2011-05-15

    We apply the ''natural fueling mechanism'' [W. Wan, S. E. Parker, Y. Chen, and F. W. Perkins, Phys. Plasmas 17, 040701 (2010)] to the edge pedestal. The natural fueling mechanism is where cold ions naturally pinch radially inward for a heat-flux dominated plasma. It is shown from neoclassical-neutral transport coupled simulations that the recycling neutrals and the associated source ions are colder than the main ions in the edge pedestal. These recycling source ions will pinch radially inward due to microturbulence. Gyrokinetic turbulence simulations indicate that near the top of the pedestal, the pinch velocity of the recycling source ions is much higher than the main ion outgoing flow velocity. The turbulent pinch of the recycling source ions may play a role in the edge pedestal transport and dynamics. The cold ion temperature significantly enhances the pinch velocity of the recycling source ions near to the pedestal top. Neoclassical calculations show a cold ion pinch in the pedestal as well.

  8. Persistent Cold Air Outbreaks over North America in a Warming Climate

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Gao, Yang; Leung, Lai-Yung R.; Lu, Jian; Masato, Giacomo

    2015-03-30

    This study examines future changes of cold air outbreaks (CAO) using a multi-model ensemble of global climate simulations from the Coupled Model Intercomparison Project Phase 5 as well as regional high resolution climate simulations. In the future, while robust decrease of CAO duration dominates in most regions, the magnitude of decrease over northwestern U.S. is much smaller than the surrounding regions. We identified statistically significant increases in sea level pressure during CAO events centering over Yukon, Alaska, and Gulf of Alaska that advects continental cold air to northwestern U.S., leading to blocking and CAO events. Changes in large scale circulationmorecontribute to about 50% of the enhanced sea level pressure anomaly conducive to CAO in northwestern U.S. in the future. High resolution regional simulations revealed potential contributions of increased existing snowpack to increased CAO in the near future over the Rocky Mountain, southwestern U.S., and Great Lakes areas through surface albedo effects, despite winter mean snow water equivalent decreases in the future. Overall, the multi-model projections emphasize that cold extremes do not completely disappear in a warming climate. Concomitant with the relatively smaller reduction in CAO events in northwestern U.S., the top 5 most extreme CAO events may still occur in the future, and wind chill warning will continue to have societal impacts in that region.less

  9. Persistent Cold Air Outbreaks over North America in a Warming Climate

    SciTech Connect (OSTI)

    Gao, Yang; Leung, Lai-Yung R.; Lu, Jian; Masato, Giacomo

    2015-03-30

    This study examines future changes of cold air outbreaks (CAO) using a multi-model ensemble of global climate simulations from the Coupled Model Intercomparison Project Phase 5 as well as regional high resolution climate simulations. In the future, while robust decrease of CAO duration dominates in most regions, the magnitude of decrease over northwestern U.S. is much smaller than the surrounding regions. We identified statistically significant increases in sea level pressure during CAO events centering over Yukon, Alaska, and Gulf of Alaska that advects continental cold air to northwestern U.S., leading to blocking and CAO events. Changes in large scale circulation contribute to about 50% of the enhanced sea level pressure anomaly conducive to CAO in northwestern U.S. in the future. High resolution regional simulations revealed potential contributions of increased existing snowpack to increased CAO in the near future over the Rocky Mountain, southwestern U.S., and Great Lakes areas through surface albedo effects, despite winter mean snow water equivalent decreases in the future. Overall, the multi-model projections emphasize that cold extremes do not completely disappear in a warming climate. Concomitant with the relatively smaller reduction in CAO events in northwestern U.S., the top 5 most extreme CAO events may still occur in the future, and wind chill warning will continue to have societal impacts in that region.

  10. Vitrification of HLW Produced by Uranium/Molybdenum Fuel Reprocessing in COGEMA's Cold Crucible Melter

    SciTech Connect (OSTI)

    Do Quang, R.; Petitjean, V.; Hollebecque, F.; Pinet, O.; Flament, T.; Prod'homme, A.

    2003-02-25

    The performance of the vitrification process currently used in the La Hague commercial reprocessing plants has been continuously improved during more than ten years of operation. In parallel COGEMA (industrial Operator), the French Atomic Energy Commission (CEA) and SGN (respectively COGEMA's R&D provider and Engineering) have developed the cold crucible melter vitrification technology to obtain greater operating flexibility, increased plant availability and further reduction of secondary waste generated during operations. The cold crucible is a compact water-cooled melter in which the radioactive waste and the glass additives are melted by direct high frequency induction. The cooling of the melter produces a solidified glass layer that protects the melter's inner wall from corrosion. Because the heat is transferred directly to the melt, high operating temperatures can be achieved with no impact on the melter itself. COGEMA plans to implement the cold crucible technology to vitrify high level liquid waste from reprocessed spent U-Mo-Sn-Al fuel (used in gas cooled reactor). The cold crucible was selected for the vitrification of this particularly hard-to-process waste stream because it could not be reasonably processed in the standard hot induction melters currently used at the La Hague vitrification facilities : the waste has a high molybdenum content which makes it very corrosive and also requires a special high temperature glass formulation to obtain sufficiently high waste loading factors (12 % in molybdenum). A special glass formulation has been developed by the CEA and has been qualified through lab and pilot testing to meet standard waste acceptance criteria for final disposal of the U-Mo waste. The process and the associated technologies have been also being qualified on a full-scale prototype at the CEA pilot facility in Marcoule. Engineering study has been integrated in parallel in order to take into account that the Cold Crucible should be installed remotely in one of the R7 vitrification cell. This paper will present the results obtained in the framework of these qualification programs.

  11. Building America Whole-House Solutions for New Home: Fort Devens: Cold Climate Market-Rate Townhomes

    Broader source: Energy.gov [DOE]

    Fort Devens: Cold Climate Market-Rate Townhomes Targeting HERS Index of 40, Harvard, Massachusetts (Fact Sheet), Building America Case Study: Efficient Solutions for New and Existing Homes, Building Technologies Office (BTO)

  12. Parametric time series analysis of cold and hot spells in daily temperature: An application in Southern Italy

    SciTech Connect (OSTI)

    Macchiato, M. ); Serio, C. ); Lapenna, V. ); Rotonda, L.La. )

    1993-07-01

    The statistical analysis of cold air temperatures (cold spells) and hot air temperatures (hot spells) is discussed. Air temperature time series observed at 50 stations in southern Italy are investigated. The deterministic and stochastic components of the time series are identified and described by a dynamic-stochastic model that is periodic in the deterministic part (the annual cycle) and Markovian (first-order autoregressive) in the stochastic part. The annual cycle is described by only a few Fourier coefficients. Based on the model fitted to the data, the theoretical probability of cold (hot) spells is computed and compared to that estimated from the observed data. Spatial patterns of identified that make it possible to extrapolate the probability of cold (hot) spells at locations where no direct observations are available. 19 refs., 13 figs., 2 tabs.

  13. Building America Best Practices Series Volume 12: Builders Challenge Guide to 40% Whole-House Energy Savings in the Cold and Very Cold Climates

    SciTech Connect (OSTI)

    Baechler, Michael C.; Gilbride, Theresa L.; Hefty, Marye G.; Cole, Pamala C.; Love, Pat M.

    2011-02-01

    This best practices guide is the twelfth in a series of guides for builders produced by PNNL for the U.S. Department of Energy’s Building America program. This guide book is a resource to help builders design and construct homes that are among the most energy-efficient available, while addressing issues such as building durability, indoor air quality, and occupant health, safety, and comfort. With the measures described in this guide, builders in the cold and very cold climates can build homes that have whole-house energy savings of 40% over the Building America benchmark with no added overall costs for consumers. The best practices described in this document are based on the results of research and demonstration projects conducted by Building America’s research teams. Building America brings together the nation’s leading building scientists with over 300 production builders to develop, test, and apply innovative, energy-efficient construction practices. Building America builders have found they can build homes that meet these aggressive energy-efficiency goals at no net increased costs to the homeowners. Currently, Building America homes achieve energy savings of 40% greater than the Building America benchmark home (a home built to mid-1990s building practices roughly equivalent to the 1993 Model Energy Code). The recommendations in this document meet or exceed the requirements of the 2009 IECC and 2009 IRC and thos erequirements are highlighted in the text. This document will be distributed via the DOE Building America website: www.buildingamerica.gov.

  14. Locating hot and cold-legs in a nuclear powered steam generation system

    DOE Patents [OSTI]

    Ekeroth, Douglas E.; Corletti, Michael M.

    1993-01-01

    A nuclear reactor steam generator includes a reactor vessel for heating water and a steam generator with a pump casing at the lowest point on the steam generator. A cold-leg pipe extends horizontally between the steam generator and the reactor vessel to return water from the steam generator to the reactor vessel. The bottom of the cold-leg pipe is at a first height above the bottom of the reactor vessel. A hot-leg pipe with one end connected to the steam generator and a second end connected to the reactor vessel has a first pipe region extending downwardly from the steam generator to a location between the steam generator and the reactor vessel at which a bottom of the hot-leg pipe is at a second height above the bottom of the reactor vessel. A second region extends from that location in a horizontal direction at the second height to the point at which the hot-leg pipe connects to the reactor vessel. A pump is attached to the casing at a location below the first and second heights and returns water from the steam generator to the reactor vessel over the cold-leg. The first height is greater than the second height and the bottom of the steam generator is at a height above the bottom of the reactor vessel that is greater than the first and second heights. A residual heat recovery pump is below the hot-leg and has an inlet line from the hot-leg that slopes down continuously to the pump inlet.

  15. Nucleus-nucleus cold fusion reactions analyzed with the l-dependent 'fusion by diffusion' model

    SciTech Connect (OSTI)

    Cap, T.; Siwek-Wilczynska, K.; Wilczynski, J.

    2011-05-15

    We present a modified version of the Fusion by Diffusion (FBD) model aimed at describing the synthesis of superheavy nuclei in cold fusion reactions, in which a low excited compound nucleus emits only one neutron. The modified FBD model accounts for the angular momentum dependence of three basic factors determining the evaporation residue cross section: the capture cross section {sigma}{sub cap}(l), the fusion probability P{sub fus}(l), and the survival probability P{sub surv}(l). The fusion hindrance factor, the inverse of P{sub fus}(l), is treated in terms of thermal fluctuations in the shape degrees of freedom and is expressed as a solution of the Smoluchowski diffusion equation. The l dependence of P{sub fus}(l) results from the l-dependent potential energy surface of the colliding system. A new parametrization of the distance of starting point of the diffusion process is introduced. An analysis of a complete set of 27 excitation functions for production of superheavy nuclei in cold fusion reactions, studied in experiments at GSI Darmstadt, RIKEN Tokyo, and LBNL Berkeley, is presented. The FBD model satisfactorily reproduces shapes and absolute cross sections of all the cold fusion excitation functions. It is shown that the peak position of the excitation function for a given 1n reaction is determined by the Q value of the reaction and the height of the fission barrier of the final nucleus. This fact could possibly be used in future experiments (with well-defined beam energy) for experimental determination of the fission barrier heights.

  16. Unconventional states and geometric effects in mesoscopic systems of ultra-cold atomic Fermi gases

    SciTech Connect (OSTI)

    Bolech, C. J.

    2014-10-15

    During the last decade, experiments all over the world started to test the superconducting state of matter using a newly developed mesoscopic tunable system: trapped ultra-cold atomic gases. Theorists and experimentalists hand-in-hand are now able to advance our understanding of the superconducting state by asking new questions that probe further into the physical mechanisms underlying the phenomenon and the door is open to the exploration of exotic unconventional superconducting states. In particular, a series of experiments on systems of trapped cold atomic gases were aimed at studying the effects of polarization on superconducting pairing. Two different experimental groups encountered surprising qualitative and quantitative discrepancies which seemed to be a function of the confining geometry and the cooling protocol. Our numerical studies demonstrate a tendency towards metastability and suggest an explanation for the observed discrepancy. From our calculations, the most likely solution which is consistent with the experiments supports a state strikingly similar to the so called FFLO state (after Ferrell, Fulde, Larkin and Ovchinnikov), which had been theorized long ago but eluded detection so far. Moreover, the three-dimensional scenario described above is reminiscent of predictions for one-dimensional systems of dilute polarized attractive gases and another set of ultra-cold-atom experiments incorporates optical lattices to study this reduced-dimensionality setting. The measurements are in quantitative agreement with theoretical calculations (using a wide array of numerical and analytic techniques) in which a partially polarized phase is found to be the one-dimensional analogue of the FFLO state. Moreover, exploring the dimensional-crossover regime, our latest findings indicate that the mesoscopic nature of these quasi-one-dimensional systems favors the appearance of a new type of Mott phase transition involving an emergent pair-superfluid of equal-spin fermions.

  17. Locating hot and cold-legs in a nuclear powered steam generation system

    DOE Patents [OSTI]

    Ekeroth, D.E.; Corletti, M.M.

    1993-11-16

    A nuclear reactor steam generator includes a reactor vessel for heating water and a steam generator with a pump casing at the lowest point on the steam generator. A cold-leg pipe extends horizontally between the steam generator and the reactor vessel to return water from the steam generator to the reactor vessel. The bottom of the cold-leg pipe is at a first height above the bottom of the reactor vessel. A hot-leg pipe with one end connected to the steam generator and a second end connected to the reactor vessel has a first pipe region extending downwardly from the steam generator to a location between the steam generator and the reactor vessel at which a bottom of the hot-leg pipe is at a second height above the bottom of the reactor vessel. A second region extends from that location in a horizontal direction at the second height to the point at which the hot-leg pipe connects to the reactor vessel. A pump is attached to the casing at a location below the first and second heights and returns water from the steam generator to the reactor vessel over the cold-leg. The first height is greater than the second height and the bottom of the steam generator is at a height above the bottom of the reactor vessel that is greater than the first and second heights. A residual heat recovery pump is below the hot-leg and has an inlet line from the hot-leg that slopes down continuously to the pump inlet. 2 figures.

  18. OTEC (Ocean Thermal Energy Conversion) CWP (Cold Water Pipe) Laboratory Test Program. Materials Project Test Report

    SciTech Connect (OSTI)

    Not Available

    1981-04-01

    Fiberglass sandwich wall structures emerged as leading candidates for the OTEC cold water pipe because of their high strength to weight ratio, their flexibility in selecting directional properties, their resistance to electrochemical interaction, their ease of deployment and their relative low cost. A review of the literature established reasonable confidence that FRP laminates could meet the OTEC requirements; however, little information was available on the performance of core materials suitable for OTEC applications. Syntactic foam cores of various composition and density were developed and tested for mechanical properties and seawater absorption.

  19. Investigations of the deuterium-deuterium fusion reaction in cast, annealed, and cold-rolled palladium

    SciTech Connect (OSTI)

    Ilic, R.; Rant, J.; Sutej, T.; Dobersek, M.; Kristof, E.; Skvarc, J.; Kozelj, M. )

    1990-11-01

    This paper reports on a search conducted for neutrons, protons, tritons, {sup 3}He ions, gamma rays, and ion-induced X-rays from deuterium-deuterium (D-D) fusion in cast (36-g), annealed (4-g), and cold-rolled (16-g) palladium specimens and a palladium hydrogen thermal valve (11 g) electrochemically charged with deuterium. The palladium cathodes were charged in an electrolytic cell (0.1 M LiOD (99.8% deuterium), platinum anode) at a current density of 25 mA/cm{sup 2} from 20 to 140 h.

  20. Quantum chaos of a mixed open system of kicked cold atoms

    SciTech Connect (OSTI)

    Krivolapov, Yevgeny; Fishman, Shmuel; Ott, Edward; Antonsen, Thomas M. [Physics Department, Technion-Israel Institute of Technology, Haifa 32000 (Israel); University of Maryland, College Park, Maryland 20742 (United States)

    2011-01-15

    The quantum and classical dynamics of particles kicked by a Gaussian attractive potential are studied. Classically, it is an open mixed system (the motion in some parts of the phase space is chaotic, and in some parts it is regular). The fidelity (Loschmidt echo) is found to exhibit oscillations that can be determined from classical considerations but are sensitive to phase space structures that are smaller than Planck's constant. Families of quasienergies are determined from classical phase space structures. Substantial differences between the classical and quantum dynamics are found for time-dependent scattering. It is argued that the system can be experimentally realized by cold atoms kicked by a Gaussian light beam.

  1. Influence of projectile neutron number on cross section in cold fusion reactions

    SciTech Connect (OSTI)

    Dragojevic, Irena; Dragojevic, I.; Gregorich, K.E.; Dullmann, Ch.E.; Folden III, C.M.; Garcia, M.A.; Gates, J.M.; Nelson, S.L.; Sudowe, R.; Nitsche, H.

    2007-09-01

    Elements 107-112 [1,2] have been discovered in reactions between {sup 208}Pb or {sup 209}Bi targets and projectiles ranging from {sup 54}Cr through {sup 70}Zn. In such reactions, the compound nucleus can be formed at excitation energies as low as {approx}12 MeV, thus this type of reaction has been referred to as 'cold fusion'. The study of cold fusion reactions is an indispensable approach to gaining a better understanding of heavy element formation and decay. A theoretical model that successfully predicts not only the magnitudes of cold fusion cross sections, but also the shapes of excitation functions and the cross section ratios between various reaction pairs was recently developed by Swiatecki, Siwek-Wilczynska, and Wilczynski [3,4]. This theoretical model, also referred to as Fusion by Diffusion, has been the guide in all of our cold fusion studies. One particularly interesting aspect of this model is the large predicted difference in cross sections between projectiles differing by two neutrons. The projectile pair where this difference is predicted to be largest is {sup 48}Ti and {sup 50}Ti. To test and extend this model, {sup 208}Pb({sup 48}Ti,n){sup 255}Rf and {sup 208}Pb({sup 50}Ti,n){sup 257}Rf excitation functions were recently measured at the Lawrence Berkeley National Laboratory's (LBNL) 88-Inch Cyclotron utilizing the Berkeley Gas-filled Separator (BGS). The {sup 50}Ti reaction was carried out with thin lead targets ({approx}100 {micro}g/cm{sup 2}), and the {sup 48}Ti reaction with both thin and thick targets ({approx}470 {micro}g/cm{sup 2}). In addition to this reaction pair, reactions with projectile pairs {sup 52}Cr and {sup 54}Cr [5], {sup 56}Fe and {sup 58}Fe [6], and {sup 62}Ni [7] and {sup 64}Ni [8] will be discussed and compared to the Fusion by Diffusion predictions. The model predictions show a very good agreement with the data.

  2. Cold fusion by electrolysis in a light water-potassium carbonate solution with a nickel electrode

    SciTech Connect (OSTI)

    Notoya, Reiko )

    1993-09-01

    The evolution of a large amount of heat, unexplainable by ordinary chemical reactions, was observed in an electrolytic cell with a nickel cathode and a platinum anode in a potassium carbonate-light water solution. The nickel cathode had a specially designed porous structure, based on fundamental knowledge concerning the active hydrogen electrode in alkaline solutions. An increase in the concentration of calcium ions was observed in the electrolyte, which seems to be the result of potassium-hydrogen cold fusion. 5 refs., 4 figs.

  3. Magnetic filter apparatus and method for generating cold plasma in semicoductor processing

    DOE Patents [OSTI]

    Vella, Michael C.

    1996-01-01

    Disclosed herein is a system and method for providing a plasma flood having a low electron temperature to a semiconductor target region during an ion implantation process. The plasma generator providing the plasma is coupled to a magnetic filter which allows ions and low energy electrons to pass therethrough while retaining captive the primary or high energy electrons. The ions and low energy electrons form a "cold plasma" which is diffused in the region of the process surface while the ion implantation process takes place.

  4. Magnetic filter apparatus and method for generating cold plasma in semiconductor processing

    DOE Patents [OSTI]

    Vella, M.C.

    1996-08-13

    Disclosed herein is a system and method for providing a plasma flood having a low electron temperature to a semiconductor target region during an ion implantation process. The plasma generator providing the plasma is coupled to a magnetic filter which allows ions and low energy electrons to pass therethrough while retaining captive the primary or high energy electrons. The ions and low energy electrons form a ``cold plasma`` which is diffused in the region of the process surface while the ion implantation process takes place. 15 figs.

  5. Cold- and Beam Test of the First Prototypes of the Superstructure for the TESLA Collider

    SciTech Connect (OSTI)

    Baboi, Nicoleta

    2003-08-08

    After three years of preparation, two superstructures, each made of two superconducting 7-cell weakly coupled subunits, have been installed in the TESLA Test Facility linac (TTF) for the cold- and beam-test. The energy stability, the HOMs damping, the frequency and the field adjustment methods were tested. The measured results confirmed expectation on the superstructure performance and proved that alternative layout for the 800 GeV upgrade of the TESLA collider, as it was proposed in TDR, is feasible. We report on the test and give here an overview of its results which are commented in more detail elsewhere in these Proceedings.

  6. Phase-mixing of electrostatic modes in a cold magnetized electron-positron plasma

    SciTech Connect (OSTI)

    Maity, Chandan; Chakrabarti, Nikhil

    2013-08-15

    In a fluid description, we study space-time evolution of electrostatic oscillations in a cold magnetized electron-positron plasma. Nonlinear results up to third order, obtained by employing a simple perturbation technique, indicate phase-mixing and thus breaking of excited oscillations, and provide an expression for the phase-mixing time. It is shown that an increase in the strength of ambient magnetic field results in an increase in the phase-mixing time. The results of our investigation will be of relevance to astrophysical environments as well as laboratory experiments.

  7. Spent Nuclear Fuel (SNF) Project Cold Vacuum Drying (CVD) Facility Operations Manual

    SciTech Connect (OSTI)

    IRWIN, J.J.

    2000-11-18

    The mission of the Spent Nuclear Fuel (SNF) Project Cold Vacuum Drying Facility (CVDF) is to achieve the earliest possible removal of free water from Multi-Canister Overpacks (MCOs). The MCOs contain metallic uranium SNF that have been removed from the 100K Area fuel storage water basins (i.e., the K East and K West Basins) at the US. Department of Energy Hanford Site in Southeastern Washington state. Removal of free water is necessary to halt water-induced corrosion of exposed uranium surfaces and to allow the MCOs and their SNF payloads to be safely transported to the Hanford Site 200 East Area and stored within the SNF Project Canister Storage Building (CSB). The CVDF is located within a few hundred yards of the basins, southwest of the 165KW Power Control Building and the 105KW Reactor Building. The site area required for the facility and vehicle circulation is approximately 2 acres. Access and egress is provided by the main entrance to the 100K inner area using existing roadways. The CVDF will remove free. water from the MCOs to reduce the potential for continued fuel-water corrosion reactions. The cold vacuum drying process involves the draining of bulk water from the MCO and subsequent vacuum drying. The MCO will be evacuated to a pressure of 8 torr or less and backfilled with an inert gas (helium). The MCO will be sealed, leak tested, and then transported to the CSB within a sealed shipping cask. (The MCO remains within the same shipping Cask from the time it enters the basin to receive its SNF payload until it is removed from the Cask by the CSB MCO handling machine.) The CVDF subproject acquired the required process systems, supporting equipment, and facilities. The cold vacuum drying operations result in an MCO containing dried fuel that is prepared for shipment to the CSB by the Cask transportation system. The CVDF subproject also provides equipment to dispose of solid wastes generated by the cold vacuum drying process and transfer process water removed from the MCO back to the K Basins.

  8. Demonstration of achromatic cold-neutron microscope utilizing axisymmetric focusing mirrors

    SciTech Connect (OSTI)

    Liu, D.; Khaykovich, B. [Nuclear Reactor Laboratory, Massachusetts Institute of Technology, 138 Albany St., Cambridge, Massachusetts 02139 (United States)] [Nuclear Reactor Laboratory, Massachusetts Institute of Technology, 138 Albany St., Cambridge, Massachusetts 02139 (United States); Hussey, D.; Jacobson, D.; Arif, M. [Physical Measurement Laboratory, NIST, Gaithersburg, Maryland 20899-8461 (United States)] [Physical Measurement Laboratory, NIST, Gaithersburg, Maryland 20899-8461 (United States); Gubarev, M. V.; Ramsey, B. D. [Marshall Space Flight Center, NASA, VP62, Huntsville, Alabama 35812 (United States)] [Marshall Space Flight Center, NASA, VP62, Huntsville, Alabama 35812 (United States); Moncton, D. E. [Nuclear Reactor Laboratory, Massachusetts Institute of Technology, 138 Albany St., Cambridge, Massachusetts 02139 (United States) [Nuclear Reactor Laboratory, Massachusetts Institute of Technology, 138 Albany St., Cambridge, Massachusetts 02139 (United States); Department of Physics, Massachusetts Institute of Technology, 77 Massachusetts Ave., Cambridge, Massachusetts 02139 (United States)

    2013-05-06

    An achromatic cold-neutron microscope with magnification 4 is demonstrated. The image-forming optics is composed of nested coaxial mirrors of full figures of revolution, so-called Wolter optics. The spatial resolution, field of view, and depth of focus are measured and found consistent with ray-tracing simulations. Methods of increasing the resolution and magnification are discussed, as well as the scientific case for the neutron microscope. In contrast to traditional pinhole-camera neutron imaging, the resolution of the microscope is determined by the mirrors rather than by the collimation of the beam, leading to possible dramatic improvements in the signal rate and resolution.

  9. Method for analyzing the mass of a sample using a cold cathode ionization source mass filter

    DOE Patents [OSTI]

    Felter, Thomas E.

    2003-10-14

    An improved quadrupole mass spectrometer is described. The improvement lies in the substitution of the conventional hot filament electron source with a cold cathode field emitter array which in turn allows operating a small QMS at much high internal pressures then are currently achievable. By eliminating of the hot filament such problems as thermally "cracking" delicate analyte molecules, outgassing a "hot" filament, high power requirements, filament contamination by outgas species, and spurious em fields are avoid all together. In addition, the ability of produce FEAs using well-known and well developed photolithographic techniques, permits building a QMS having multiple redundancies of the ionization source at very low additional cost.

  10. MERGING COLD FRONTS IN THE GALAXY PAIR NGC 7619 AND NGC 7626

    SciTech Connect (OSTI)

    Randall, S. W.; Jones, C.; Kraft, R.; Forman, W. R.; O'Sullivan, E.

    2009-05-10

    We present results from Chandra observations of the galaxy pair NGC 7619 and NGC 7626, the two dominant members of the Pegasus group. The X-ray images show a brightness edge associated with each galaxy, which we identify as merger cold fronts. The edges are sharp, and the axes of symmetry of the edges are roughly antiparallel, suggesting that these galaxies are falling toward one another in the plane of the sky. The detection of merger cold fronts in each of the two dominant member galaxies implies a merging subgroup scenario, since the alternative is that the galaxies are falling into a preexisting {approx}1 keV halo without a dominant galaxy of its own, and such objects are not observed. We estimate the three-dimensional velocities from the cold fronts and, using the observed radial velocities of the galaxies, show that the velocity vectors are indeed most likely close to the plane of the sky, with a relative velocity of {approx}1190 km s{sup -1}. The relative velocity is consistent with what is expected from the infall of two roughly equal mass subgroups whose total viral mass equals that of the Pegasus group. We conclude that the Pegasus cluster is most likely currently forming from a major merger of two subgroups, dominated by NGC 7619 and NGC 7626. NGC 7626 contains a strong radio source, consisting of a core with two symmetric jets, and radio lobes. Although we find no associated structure in the X-ray surface brightness map, the temperature map reveals a clump of cool gas just outside the southern lobe, presumably entrained by the lobe, and possibly an extension of cooler gas into the lobe itself. The jet axis is parallel with the projected direction of motion of NGC 7626 (inferred from the symmetry axis of the merger cold front), and the southern leading jet is foreshortened as compared to the northern trailing one, possibly due to the additional ram pressure encountered by the forward jet.

  11. The Herschel cold debris disks: Confusion with the extragalactic background at 160 ?m

    SciTech Connect (OSTI)

    Gspr, Andrs; Rieke, George H. [Steward Observatory, University of Arizona, Tucson, AZ 85721 (United States)

    2014-03-20

    The Herschel 'DUst around NEarby Stars' (DUNES) survey has found a number of debris disk candidates that are apparently very cold, with temperatures near 22 K. It has proven difficult to fit their spectral energy distributions with conventional models for debris disks. Given this issue, we carefully examine the alternative explanation that the detections arise from confusion with infrared cirrus and/or background galaxies that are not physically associated with the foreground stars. We find that such an explanation is consistent with all of these detections.

  12. Final Report - Spent Nuclear Fuel Retrieval System Manipulator System Cold Validation Testing

    SciTech Connect (OSTI)

    D.R. Jackson; G.R. Kiebel

    1999-08-24

    Manipulator system cold validation testing (CVT) was performed in support of the Fuel Retrieval System (FRS) Sub-Project, a subtask of the Spent Nuclear Fuel Project at the Hanford Site in Richland, Washington. The FRS will be used to retrieve and repackage K-Basin Spent Nuclear Fuel (SNF) currently stored in old K-Plant storage basins. The FRS is required to retrieve full fuel canisters from the basin; clean the fuel elements inside the canister to remove excessive uranium corrosion products (or sludge); remove the contents from the canisters; and sort the resulting debris, scrap, and fuel for repackaging. The fuel elements and scrap will be collected in fuel storage and scrap baskets in preparation for loading into a multi canister overpack (MCO), while the debris is loaded into a debris bin and disposed of as solid waste. The FRS is composed of three major subsystems. The Manipulator Subsystem provides remote handling of fuel, scrap, and debris; the In-Pool Equipment subsystem performs cleaning of fuel and provides a work surface for handling materials; and the Remote Viewing Subsystem provides for remote viewing of the work area by operators. There are two complete and identical FRS systems, one to be installed in the K-West basin and one to be installed in the K-East basin. Another partial system will be installed in a cold test facility to provide for operator training.

  13. LNG Vehicle High-Pressure Fuel System and ''Cold Energy'' Utilization

    SciTech Connect (OSTI)

    powers,Charles A.; Derbidge, T. Craig

    2001-03-27

    A high-pressure fuel system for LNG vehicles with direct-injection natural gas engines has been developed and demonstrated on a heavy-duty truck. A new concept for utilizing the ''cold energy'' associated with LNG vehicles to generate mechanical power to drive auxiliary equipment (such as high-pressure fuel pumps) has also been developed and demonstrated in the laboratory. The high-pressure LNG fuel system development included the design and testing of a new type of cryogenic pump utilizes multiple chambers and other features to condense moderate quantities of sucked vapor and discharge supercritical LNG at 3,000 to 4,000 psi. The pump was demonstrated on a Class 8 truck with a Westport high-pressure direct-injection Cummins ISX engine. A concept that utilizes LNG's ''cold energy'' to drive a high-pressure fuel pump without engine attachments or power consumption was developed. Ethylene is boiled and superheated by the engine coolant, and it is cooled and condensed by rejecting h eat to the LNG. Power is extracted in a full-admission blowdown process, and part of this power is applied to pump the ethylene liquid to the boiler pressure. Tests demonstrated a net power output of 1.1. hp at 1.9 Lbm/min of LNG flow, which is adequate to isentropically pump the LNG to approximately 3,400 psi..

  14. Summary Of Cold Crucible Vitrification Tests Results With Savannah River Site High Level Waste Surrogates

    SciTech Connect (OSTI)

    Stefanovsky, Sergey; Marra, James; Lebedev, Vladimir

    2014-01-13

    The cold crucible inductive melting (CCIM) technology successfully applied for vitrification of low- and intermediate-level waste (LILW) at SIA Radon, Russia, was tested to be implemented for vitrification of high-level waste (HLW) stored at Savannah River Site, USA. Mixtures of Sludge Batch 2 (SB2) and 4 (SB4) waste surrogates and borosilicate frits as slurries were vitrified in bench- (236 mm inner diameter) and full-scale (418 mm inner diameter) cold crucibles. Various process conditions were tested and major process variables were determined. Melts were poured into 10L canisters and cooled to room temperature in air or in heat-insulated boxes by a regime similar to Canister Centerline Cooling (CCC) used at DWPF. The products with waste loading from ~40 to ~65 wt.% were investigated in details. The products contained 40 to 55 wt.% waste oxides were predominantly amorphous; at higher waste loadings (WL) spinel structure phases and nepheline were present. Normalized release values for Li, B, Na, and Si determined by PCT procedure remain lower than those from EA glass at waste loadings of up to 60 wt.%.

  15. A review of research in ``cold fusion`` and its impact on energy conservation

    SciTech Connect (OSTI)

    Hurtak, J.J.; Bailey, P.G.

    1995-12-31

    During the past six years, cold fusion enhancement through a variety of research techniques has grown at a rapid rate to the point where it now can be regarded as a major field of endeavor, a second generation heat transfer technology. Observations have been made of deuteron-deuteron (d-d) fusion at room temperature during low voltage electrolytic infusion of deuterons into metallic titanium or palladium electrodes. Neutrons with and energy of approximately 2.5 MeV were with a sensitive neutron spectrometer at a rate of 2 {times} 10{sup {minus}3} n/s, which cannot be accounted for by ambient-neutron background variations. These reactions have been known to yield an excited helium nucleus ({sup 4} He) with approximately 23.8 MeV excess energy, where d+d= {sup 4}He + energy. In most successful experiments, 1% to 50% more heat than the input of electric power into the electrolytic cells has been recorded. These experiments are being successfully repeated on an international basis. Some of these results and various theories proposed to explain this phenomena are presented. Possible applications of ``cold fusion`` technology are given, and its impact on energy conservation is discussed.

  16. Mass spectrometric helium analysis of solid and gas samples from cold-fusion type experiments

    SciTech Connect (OSTI)

    Oliver, B.M.

    1995-12-01

    A custom mass spectrometer system, operating in static mode, has been used to measure helium in both solid and gas samples front cold-fusion type experiments. The mass spectrometer is a 2-in. Radius, 60{degrees}, permanent angle magnet instrument with a single electron-multiplier collecting. Depending on the absolute levels of helium expected, the analysis are conducted by isotope dilution or by measuring absolute collector values. Solid samples are vaporized to ensure complete helium release. Prior to analysis, the fraction of sample gas to be analyzed is exposed to a series of physical and chemical getters, including room temperature Zr-Al alloy (SAES type 101) and liquid-nitrogen cooled activated charcoal. This is done to remove active gases and hydrogen isotopes which could interfere with the helium determinations. Generally, the analysis protocol is to analyze an equal or greater number of {open_quotes}controls{close_quotes} along with the samples to accurately characterize system background and reproducibility. Absolute sensitivity for the system is approximately 1 x 10{sup 9} atoms. Absolute accuracy is 1% or better for helium levels > 10{sup 11} atoms. With few exceptions, helium analysis of solid samples front cold fusion type experiments have yielded no excess helium above usual system background. A few samples have shown helium levels in the low 10{sup 9} atom range, and some gas samples have shown {sup 4}He levels up to several hundred ppm.

  17. Investigation of the effect of mechanical stress on cold fusion. Master's thesis

    SciTech Connect (OSTI)

    Wohl, B.H.

    1990-03-01

    The purpose of this research was to see if the phenomenon known as cold fusion could be observed after loading a sample of titanium with deuterium gas and then subjecting the sample to mechanical stress. Samples of commercially pure titanium were loaded with deuterium by heating them inductively to 643 + or - 4 C while they were in a deuterium atmosphere. After loading, the samples were subjected to either dynamic tensile stress, a static load, or shear stress. The samples were surrounded by a 4-pi neutron detector during the application of stress and data from the detection system was analyzed for either large bursts of neutrons or continuous low-level emission of neutrons. Despite the fact that the neutron detection system was sensitive to certain environmental factors, application of tensile stress caused no positive indications of cold fusion. One suspiciously large count did occur during the application of shear stress, but that part of the experiment was relatively uncontrolled, and it is believed that the one large count was caused by environmental factors. An upper limit of 1.2 x 10 to the -24th power neutrons/deuteron pair/s has been calculated for the samples involved in the research. This is based on the limits of sensitivity of the neutron detection system.

  18. 2011 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site's Advanced Test Reactor Complex Cold Waste Pond

    SciTech Connect (OSTI)

    Mike Lewis

    2012-02-01

    This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (LA 000161 01, Modification B), for the wastewater land application site at the Idaho National Laboratory Site's Advanced Test Reactor Complex Cold Waste Pond from November 1, 2010 through October 31, 2011. The report contains the following information: Facility and system description Permit required effluent monitoring data and loading rates Groundwater monitoring data Status of compliance activities Noncompliance and other issues Discussion of the facility's environmental impacts During the 2011 permit year, approximately 166 million gallons of wastewater were discharged to the Cold Waste Pond. This is well below the maximum annual permit limit of 375 million gallons. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest near the Cold Waste Pond and decrease rapidly as the distance from the Cold Waste Pond increases. Although concentrations of sulfate and total dissolved solids are elevated near the Cold Waste Pond, both parameters were below the Ground Water Quality Rule Secondary Constituent Standards in the down gradient monitoring wells.

  19. 2012 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site's Advanced Test Reactor Complex Cold Waste Pond

    SciTech Connect (OSTI)

    Mike Lewis

    2013-02-01

    This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (#LA 000161 01, Modification B), for the wastewater land application site at the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond from November 1, 2011 through October 31, 2012. The report contains the following information: Facility and system description Permit required effluent monitoring data and loading rates Groundwater monitoring data Status of compliance activities Noncompliance issues Discussion of the facility’s environmental impacts During the 2012 permit year, approximately 183 million gallons of wastewater were discharged to the Cold Waste Pond. This is well below the maximum annual permit limit of 375 million gallons. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest near the Cold Waste Pond and decrease rapidly as the distance from the Cold Waste Pond increases. Although concentrations of sulfate and total dissolved solids are elevated near the Cold Waste Pond, both parameters were below the Ground Water Quality Rule Secondary Constituent Standards in the down gradient monitoring wells.

  20. Cold-Start Performance and Emissions Behavior of Alcohol Fuels in an SIDI Engine Using Transient Hardware-In-Loop Test Meth

    Broader source: Energy.gov [DOE]

    Discusses results of cold- and hot-start transient tests using gasoline and 3 alcohol-gasoline blends (50% and 85% ethanol, and 83% iso-butanol)

  1. Thermal spray and cold spray analysis of density, porosity, and tensile Specimens for use with LIGA applications

    SciTech Connect (OSTI)

    DECKER,MERLIN K.; SMITH,MARK F.

    2000-02-01

    This analysis provides a preliminary investigation into using Twin-Wire Arc Thermal Spray and Cold Spray as material deposition processes for LIGA applications. These spray material processes were studied to make an initial determination of their potential as alternatives to producing mechanical parts via the electroplating process. Three materials, UltraMachinable{reg_sign} Stainless Steel, BondArc{reg_sign}, and aluminum, were sprayed using Thermal Spray. Only aluminum was sprayed using the Cold Spray process. Following the spray procedure, the test specimens were released from a copper mold and then tested. Three tests, density, tensile strength, and porosity, were performed on the specimens to determine the spray effect on material properties. Twin-Wire Arc Thermal Spray did not demonstrate adequate deposition properties and does not appear to be a good process candidate for LIGA. However, Cold Spray yielded better density results and warrants further investigation to analyze the minimum feature size produced by the process.

  2. Systematics of calculated cold-fusion barriers for reactions leading to compound systems from Z=104 to Z=126

    SciTech Connect (OSTI)

    Moeller, P.; Armbruster, P.; Hofmann, S.; Muenzenberg, G.

    1998-12-21

    We have previously shown that just as the decay properties of nuclei in the heavy region depend strongly on shell structure, shell structure also dramatically affects the fusion entrance channel. The six most recently discovered new elements were all formed in cold-fusion reactions. We discuss here the effect of the doubly-magic structure of the target in cold-fusion reactions on the fusion barrier and present a systematic study of cold-fusion heavy-ion reaction barriers for elements from Rf to Z=126. We find that the systematics of the optimum reaction energy may change near Z=112, because here the highest point on the interaction barrier shifts in location from near the touching distance at r/R{sub 0}{approx_equal}1.5 to r/R{sub 0}{approx_equal}1.0, which is a shape configuration just slightly more deformed than the ground state.

  3. Systematics of calculated cold-fusion barriers for reactions leading to compound systems from Z=104 to Z=126

    SciTech Connect (OSTI)

    Moller, P.; Hofmann, S.; Munzenberg, G.

    1998-12-01

    We have previously shown that just as the decay properties of nuclei in the heavy region depend strongly on shell structure, shell structure also dramatically affects the fusion entrance channel. The six most recently discovered new elements were all formed in cold-fusion reactions. We discuss here the effect of the doubly-magic structure of the target in cold-fusion reactions on the fusion barrier and present a systematic study of cold-fusion heavy-ion reaction barriers for elements from Rf to Z=126. We find that the systematics of the optimum reaction energy may change near Z=112, because here the highest point on the interaction barrier shifts in location from near the touching distance at r/R{sub 0}{approx}1.5 to r/R{sub 0}{approx}1.0, which is a shape configuration just slightly more deformed than the ground state. {copyright} {ital 1998 American Institute of Physics.}

  4. Performance of the Los Alamos National Laboratory spallation-driven solid-deuterium ultra-cold neutron source

    SciTech Connect (OSTI)

    Saunders, A.; Makela, M.; Bagdasarova, Y.; Boissevain, J.; Bowles, T. J.; Currie, S. A.; Hill, R. E.; Hogan, G.; Morris, C. L.; Mortensen, R. N.; Ramsey, J.; Seestrom, S. J.; Sondheim, W. E.; Teasdale, W.; Wang, Z. [Los Alamos National Laboratory, Los Alamos, New Mexico 87544 (United States); Back, H. O.; Broussard, L. J.; Hoagland, J.; Holley, A. T.; Pattie, R. W. Jr. [Department of Physics, North Carolina State University, Raleigh, North Carolina 27695 (United States); and others

    2013-01-15

    In this paper, we describe the performance of the Los Alamos spallation-driven solid-deuterium ultra-cold neutron (UCN) source. Measurements of the cold neutron flux, the very low energy neutron production rate, and the UCN rates and density at the exit from the biological shield are presented and compared to Monte Carlo predictions. The cold neutron rates compare well with predictions from the Monte Carlo code MCNPX and the UCN rates agree with our custom UCN Monte Carlo code. The source is shown to perform as modeled. The maximum delivered UCN density at the exit from the biological shield is 52(9) UCN/cc with a solid deuterium volume of {approx}1500 cm{sup 3}.

  5. Lipocalin 2 regulation by thermal stresses: Protective role of Lcn2/NGAL against cold and heat stresses

    SciTech Connect (OSTI)

    Roudkenar, Mehryar Habibi, E-mail: roudkenar@ibto.ir [Research Center, Iranian Blood Transfusion Organization, Tehran (Iran, Islamic Republic of); Halabian, Raheleh [Research Center, Iranian Blood Transfusion Organization, Tehran (Iran, Islamic Republic of)] [Research Center, Iranian Blood Transfusion Organization, Tehran (Iran, Islamic Republic of); Roushandeh, Amaneh Mohammadi [Department of Anatomy, Faculty of Medicine, Medical University of Tabriz, Tabriz (Iran, Islamic Republic of)] [Department of Anatomy, Faculty of Medicine, Medical University of Tabriz, Tabriz (Iran, Islamic Republic of); Nourani, Mohammad Reza [Chemical Injury Research Center, Baqiyatallah Medical Science University, Tehran (Iran, Islamic Republic of)] [Chemical Injury Research Center, Baqiyatallah Medical Science University, Tehran (Iran, Islamic Republic of); Masroori, Nasser [Research Center, Iranian Blood Transfusion Organization, Tehran (Iran, Islamic Republic of)] [Research Center, Iranian Blood Transfusion Organization, Tehran (Iran, Islamic Republic of); Ebrahimi, Majid [Research Center, Iranian Blood Transfusion Organization, Tehran (Iran, Islamic Republic of) [Research Center, Iranian Blood Transfusion Organization, Tehran (Iran, Islamic Republic of); Chemical Injury Research Center, Baqiyatallah Medical Science University, Tehran (Iran, Islamic Republic of); Nikogoftar, Mahin; Rouhbakhsh, Mehdi; Bahmani, Parisa [Research Center, Iranian Blood Transfusion Organization, Tehran (Iran, Islamic Republic of)] [Research Center, Iranian Blood Transfusion Organization, Tehran (Iran, Islamic Republic of); Najafabadi, Ali Jahanian [Department of Molecular Biology, Pasteur Institute of Iran, Tehran (Iran, Islamic Republic of)] [Department of Molecular Biology, Pasteur Institute of Iran, Tehran (Iran, Islamic Republic of); Shokrgozar, Mohammad Ali [National Cell Bank of Iran, Pasteur institute of Iran, Tehran (Iran, Islamic Republic of)] [National Cell Bank of Iran, Pasteur institute of Iran, Tehran (Iran, Islamic Republic of)

    2009-11-01

    Environmental temperature variations are the most common stresses experienced by a wide range of organisms. Lipocalin 2 (Lcn2/NGAL) is expressed in various normal and pathologic conditions. However, its precise functions have not been fully determined. Here we report the induction of Lcn2 by thermal stresses in vivo, and its role following exposure to cold and heat stresses in vitro. Induction of Lcn2 in liver, heart and kidney was detected by RT-PCR, Western blot and immunohistochemistry following exposure of mice to heat and cold stresses. When CHO and HEK293T cells overexpressing NGAL were exposed to cold stress, cell proliferation was higher compared to controls. Down-regulatrion of NGAL by siRNA in A549 cells resulted in less proliferation when exposed to cold stress compared to control cells. The number of apoptotic cells and expression of pro-apoptotic proteins were lower in the NGAL overexpressing CHO and HEK293T cells, but were higher in the siRNA-transfected A549 cells compared to controls, indicating that NGAL protects cells against cold stress. Following exposure of the cells to heat stress, ectopic expression of NGAL protected cells while addition of exogenous recombinant NGAL to the cell culture medium exacerbated the toxicity of heat stress specially when there was low or no endogenous expression of NGAL. It had a dual effect on apoptosis following heat stress. NGAL also increased the expression of HO-1. Lcn2/NGAL may have the potential to improve cell proliferation and preservation particularly to prevent cold ischemia injury of transplanted organs or for treatment of some cancers by hyperthermia.

  6. 2007 TY430: A COLD CLASSICAL KUIPER BELT TYPE BINARY IN THE PLUTINO POPULATION

    SciTech Connect (OSTI)

    Sheppard, Scott S.; Ragozzine, Darin; Trujillo, Chadwick

    2012-03-15

    Kuiper Belt object 2007 TY430 is the first wide, equal-sized, binary known in the 3:2 mean motion resonance with Neptune. The two components have a maximum separation of about 1 arcsec and are on average less than 0.1 mag different in apparent magnitude with identical ultra-red colors (g - i = 1.49 {+-} 0.01 mag). Using nearly monthly observations of 2007 TY430 from 2007 to 2011, the orbit of the mutual components was found to have a period of 961.2 {+-} 4.6 days with a semi-major axis of 21000 {+-} 160 km and eccentricity of 0.1529 {+-} 0.0028. The inclination with respect to the ecliptic is 15.68 {+-} 0.22 deg and extensive observations have allowed the mirror orbit to be eliminated as a possibility. The total mass for the binary system was found to be 7.90 {+-} 0.21 Multiplication-Sign 10{sup 17} kg. Equal-sized, wide binaries and ultra-red colors are common in the low-inclination 'cold' classical part of the Kuiper Belt and likely formed through some sort of three-body interactions within a much denser Kuiper Belt. To date 2007 TY430 is the only ultra-red, equal-sized binary known outside of the classical Kuiper Belt population. Numerical simulations suggest 2007 TY430 is moderately unstable in the outer part of the 3:2 resonance and thus 2007 TY430 is likely an escaped 'cold' classical object that later got trapped in the 3:2 resonance. Similar to the known equal-sized, wide binaries in the cold classical population, the binary 2007 TY430 requires a high albedo and very low density structure to obtain the total mass found for the pair. For a realistic minimum density of 0.5 g cm{sup -3} the albedo of 2007 TY430 would be greater than 0.17. For reasonable densities, the radii of either component should be less than 60 km, and thus the relatively low eccentricity of the binary is interesting since no tides should be operating on the bodies at their large distances from each other. The low prograde inclination of the binary also makes it unlikely that the Kozai mechanism could have altered the orbit, making the 2007 TY430 binary orbit likely one of the few relatively unaltered primordial binary orbits known. Under some binary formation models, the low-inclination prograde orbit of the 2007 TY430 binary indicates formation within a relatively high velocity regime in the Kuiper Belt.

  7. Transport of thermal neutrons in different forms of liquid hydrogen and the production of intense beams of cold neutrons

    SciTech Connect (OSTI)

    Swaminathan, K.; Tewari, S.P.

    1982-10-01

    From their studies the authors find that the thermal neutron inelastic scattering kernel incorporating the chemical binding energy in liquid hydrogen is able to successfully explain various neutron transport studies such as pulsed neutron and steady-state neutron spectra. For an infinite-sized assembly, D/sub 2/ at 4 K yields a very intense flux of cold and ultracold neutrons. For the practicable finite assembly corresponding to B/sup 2/ = 0.0158 cm/sup -2/, it is found that liquid hydrogen at 11 K gives the most intense beam of cold neutrons.

  8. Insulated Concrete Form Walls Integrated With Mechanical Systems in a Cold Climate Test House

    SciTech Connect (OSTI)

    Mallay, D.; Wiehagen, J.

    2014-09-01

    Transitioning from standard light frame to a thermal mass wall system in a high performance home will require a higher level of design integration with the mechanical systems. The much higher mass in the ICF wall influences heat transfer through the wall and affects how the heating and cooling system responds to changing outdoor conditions. This is even more important for efficient, low-load homes with efficient heat pump systems in colder climates where the heating and cooling peak loads are significantly different from standard construction. This report analyzes a range of design features and component performance estimates in an effort to select practical, cost-effective solutions for high performance homes in a cold climate.

  9. GAMMA-RAY POLARIZATION INDUCED BY COLD ELECTRONS VIA COMPTON PROCESSES

    SciTech Connect (OSTI)

    Chang Zhe; Jiang Yunguo; Lin Hainan, E-mail: changz@ihep.ac.cn, E-mail: jiangyg@ihep.ac.cn, E-mail: linhn@ihep.ac.cn [Institute of High Energy Physics, Chinese Academy of Sciences, 100049 Beijing (China)

    2013-05-20

    The polarization measurement is an important tool to probe the prompt emission mechanism in gamma-ray bursts (GRBs). The synchrotron photons can be scattered by cold electrons in the outflow via Compton scattering (CS) processes. The observed polarization depends on both the photon energy and the viewing angle. With the typical bulk Lorentz factor {Gamma} {approx} 200, photons with energy E > 10 MeV tend to have smaller polarization than photons with energy E < 1 MeV. At the right viewing angle, i.e., {theta} {approx} {Gamma}{sup -1}, the polarization achieves its maximal value, and the polarization angle changes 90 Degree-Sign relative to the initial polarization direction. Thus, the synchrotron radiation plus CS model can naturally explain the 90 Degree-Sign change of the polarization angle in GRB 100826A.

  10. Bridging the Cold War and the 21st century: chronicling the history of Sandia National Laboratories

    SciTech Connect (OSTI)

    Mora, C.J.

    1997-04-01

    A historical perspective is given for Sandia National Laboratories from its beginnings as a small engineering group at an offshoot of Los Alamos Laboratory to a facility of 7000 people at its main facility in Albuquerque, another 1000 people in Livermore, California and test ranges in Tonopah, Nevada and Kauai, Hawaii. The Sandia army base became the Z division of Los Alamos and $25 million construction program began the structures that would carry out a test program for nuclear weapons during the cold war. Bell System/AT&T stewardship of the site continued from 1949 to 1993, when Martin Marietta (now Lockheed Martin) was chosen as the new contractor. Management decisions, personnel, and political aspects of the Laboratory are presented up to 1997 and forecasts are given for future policy and programs of Sandia.

  11. Dual-axis high-data-rate atom interferometer via cold ensemble exchange

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Rakholia, Akash V.; McGuinness, Hayden J.; Biedermann, Grant W.

    2014-11-24

    We demonstrate a dual-axis accelerometer and gyroscope atom interferometer, which can form the building blocks of a six-axis inertial measurement unit. By recapturing the atoms after the interferometer sequence, we maintain a large atom number at high data rates of 50 to 100 measurements per second. Two cold ensembles are formed in trap zones located a few centimeters apart and are launched toward one another. During their ballistic trajectory, they are interrogated with a stimulated Raman sequence, detected, and recaptured in the opposing trap zone. As a result, we achieve sensitivities at μg/ √Hz and μrad/s/ √Hz levels, making thismore » a compelling prospect for expanding the use of atom interferometer inertial sensors beyond benign laboratory environments.« less

  12. Exterior Insulation Implications for Heating and Cooling Systems in Cold Climates

    SciTech Connect (OSTI)

    Herk, Anastasia; Poerschke, Andrew

    2015-04-09

    The New York State Energy Research and Development Authority (NYSERDA) is interested in finding cost-effective solutions for deep energy retrofits (DERs) related to exterior wall insulation in a cold climate, with targets of 50% peak load reduction and 50% space conditioning energy savings. The U.S. Department of Energy Building America team, IBACOS, in collaboration with GreenHomes America, Inc. (GHA), was contracted by NYSERDA to research exterior wall insulation solutions. In addition to exterior wall insulation, the strategies included energy upgrades where needed in the attic, mechanical and ventilation systems, basement, band joist, walls, and floors. Under Building America, IBACOS is studying the impact of a “thermal enclosure” DER on the sizing of the space conditioning system and the occupant comfort if the thermal capacity of the heating and cooling system is dramatically downsized without any change in the existing heating and cooling distribution system (e.g., size, tightness and supply outlet configurations).

  13. Exterior Insulation Implications for Heating and Cooling Systems in Cold Climates

    SciTech Connect (OSTI)

    Herk, Anastasia; Poerschke, Andrew

    2015-04-01

    The New York State Energy Research and Development Authority (NYSERDA) is interested in finding cost-effective solutions for deep energy retrofits (DERs) related to exterior wall insulation in a cold climate, with targets of 50% peak load reduction and 50% space conditioning energy savings. The U.S. Department of Energy Building America team, IBACOS, in collaboration with GreenHomes America, Inc. (GHA), was contracted by NYSERDA to research exterior wall insulation solutions. In addition to exterior wall insulation, the strategies included energy upgrades where needed in the attic, mechanical and ventilation systems, basement, band joist, walls, and floors. Under Building America, IBACOS is studying the impact of a “thermal enclosure” DER on the sizing of the space conditioning system and the occupant comfort if the thermal capacity of the heating and cooling system is dramatically downsized without any change in the existing heating and cooling distribution system (e.g., size, tightness and supply outlet configurations).

  14. Building America Residential System Research Results: Achieving 30% Whole House Energy Savings Level in Cold Climates

    SciTech Connect (OSTI)

    Building Industry Research Alliance; Building Science Consortium; Consortium for Advanced Residential Buildings; Florida Solar Energy Center; IBACOS; National Renewable Energy Laboratory

    2006-08-01

    The Building America program conducts the system research required to reduce risks associated with the design and construction of homes that use an average of 30% to 90% less total energy for all residential energy uses than the Building America Research Benchmark, including research on homes that will use zero net energy on annual basis. To measure the program's progress, annual research milestones have been established for five major climate regions in the United States. The system research activities required to reach each milestone take from 3 to 5 years to complete and include research in individual test houses, studies in pre-production prototypes, and research studies with lead builders that provide early examples that the specified energy savings level can be successfully achieved on a production basis. This report summarizes research results for the 30% energy savings level and demonstrates that lead builders can successfully provide 30% homes in Cold Climates on a cost-neutral basis.

  15. Technology Solutions Case Study: Insulated Siding Retrofit in a Cold Climate

    SciTech Connect (OSTI)

    2015-05-01

    In this study, the U.S. Department of Energy’s team Building America Partner¬ship for Improved Residential Construction (BA-PIRC) worked with Kinsley Construction Company to evaluate the real-world performance of insulated sid¬ing when applied to an existing home. A 1960s home was selected for analysis. It is located in a cold climate (zone 6) where the addition of insulated siding and a carefully detailed water-resistive barrier have the potential to offer significant benefits. In particular, the team quantified building airtightness and heating energy use as a function of outdoor temperatures before and after the installa¬tion of the insulated siding.

  16. Dual-axis high-data-rate atom interferometer via cold ensemble exchange

    SciTech Connect (OSTI)

    Rakholia, Akash V.; McGuinness, Hayden J.; Biedermann, Grant W.

    2014-11-24

    We demonstrate a dual-axis accelerometer and gyroscope atom interferometer, which can form the building blocks of a six-axis inertial measurement unit. By recapturing the atoms after the interferometer sequence, we maintain a large atom number at high data rates of 50 to 100 measurements per second. Two cold ensembles are formed in trap zones located a few centimeters apart and are launched toward one another. During their ballistic trajectory, they are interrogated with a stimulated Raman sequence, detected, and recaptured in the opposing trap zone. As a result, we achieve sensitivities at ?g/ ?Hz and ?rad/s/ ?Hz levels, making this a compelling prospect for expanding the use of atom interferometer inertial sensors beyond benign laboratory environments.

  17. Long-pulse arc-discharge plasma source with cold cathode for diagnostic neutral beam injector

    SciTech Connect (OSTI)

    Deichuli, P. P.; Ivanov, A. A.; Stupishin, N. V.

    2008-02-15

    Long-pulse cold cathode arc-discharge plasma generators have been successfully used as high-quality hydrogen ion sources for plasma diagnostic neutral beams. One of the main advantages of this type of plasma source is a high proton fraction (80%-90%). However, the lifetime of the plasma source is limited due to intensive electrode's erosion, especially at the cathode region. An optimized design of the cathode and the nearest electrodes is found which reduces the erosion and allows us to increase the pulse length. The plasma source produces the extracted ion current up to 3 A at a low angular divergence, and at the pulse duration up to 2 s.

  18. On fusion/fission chain reactions in the Fleischmann-Pons cold fusion experiment

    SciTech Connect (OSTI)

    Anghaie, S.; Froelich, P.; Monkhorst, H.J. )

    1990-05-01

    In this paper the possibility of fusion/fission chain reactions following d-d source reactions in electrochemical cold fusion experiments have been investigated. The recycling factors for the charged particles in fusion reactions with consumable nuclei deuteron, {sup 6}Li nd {sup 7}Li, are estimated. It is concluded that, based on the established nuclear fusion cross sections and electronic stopping power, the recycling factor is four to five orders of magnitude less than required for close to critical conditions. It is argued that the cross generation of charged particles by neutrons does not play a significant role in this process, even if increased densities at the surface of electrodes do occur.

  19. Prolonged cold storage of red blood cells by oxygen removal and additive usage

    DOE Patents [OSTI]

    Bitensky, M.W.; Yoshida, Tatsuro

    1998-08-04

    Prolonged cold storage of red blood cells by oxygen removal and additive usage. A cost-effective, 4 C storage procedure that preserves red cell quality and prolongs post-transfusion in vivo survival is described. The improved in vivo survival and the preservation of adenosine triphosphate levels, along with reduction in hemolysis and membrane vesicle production of red blood cells stored at 4 C for prolonged periods of time, is achieved by reducing the oxygen level therein at the time of storage; in particular, by flushing the cells with an inert gas, and storing them in an aqueous solution which includes adenine, dextrose, mannitol, citrate ion, and dihydrogen phosphate ion, but no sodium chloride, in an oxygen-permeable container which is located in an oxygen-free environment containing oxygen-scavenging materials. 8 figs.

  20. Prolonged cold storage of red blood cells by oxygen removal and additive usage

    DOE Patents [OSTI]

    Bitensky, Mark W.; Yoshida, Tatsuro

    1998-01-01

    Prolonged cold storage of red blood cells by oxygen removal and additive usage. A cost-effective, 4.degree. C. storage procedure that preserves red cell quality and prolongs post-transfusion in vivo survival is described. The improved in vivo survival and the preservation of adenosine triphosphate levels, along with reduction in hemolysis and membrane vesicle production of red blood cells stored at 4.degree. C. for prolonged periods of time, is achieved by reducing the oxygen level therein at the time of storage; in particular, by flushing the cells with an inert gas, and storing them in an aqueous solution which includes adenine, dextrose, mannitol, citrate ion, and dihydrogen phosphate ion, but no sodium chloride, in an oxygen-permeable container which is located in an oxygen-free environment containing oxygen-scavenging materials.

  1. Cold-Climate Case Study for Affordable Zero Energy Homes: Preprint

    SciTech Connect (OSTI)

    Norton, P.; Christensen, C.

    2006-07-01

    This project, supported by the U.S. Department of Energy's Building America Program, is a case study in reaching zero energy within the affordable housing sector in cold climates. The design of the 1200 square foot, 3-bedroom Denver zero energy home carefully combines envelope efficiency, efficient equipment, appliances and lighting, and passive and active solar features to reach the zero energy goal. The home was designed using an early version of the BEOpt building optimization software with additional analysis using DOE2. This engineering approach was tempered by regular discussions with Habitat construction staff and volunteers. These discussions weighed the applicability of the optimized solutions to the special needs and economics of a Habitat house--moving the design towards simple, easily maintained mechanical systems and volunteer-friendly construction techniques.

  2. Angular distribution of products of ternary nuclear fission induced by cold polarized neutrons

    SciTech Connect (OSTI)

    Bunakov, V. E. Kadmensky, S. G. Kadmensky, S. S.

    2008-11-15

    Within quantum fission theory, angular distributions of products originating from the ternary fission of nuclei that is induced by polarized cold and thermal neutrons are investigated on the basis of a non-evaporative mechanism of third-particle emission and a consistent description of fission-channel coupling. It is shown that the inclusion of Coriolis interaction both in the region of the discrete and in the region of the continuous spectrum of states of the system undergoing fission leads to T-odd correlations in the aforementioned angular distributions. The properties of the TRI and ROT effects discovered recently, which are due to the interference between the fission amplitudes of neutron resonances, are explored. The results obtained here are compared with their counterparts from classic calculations based on the trajectory method.

  3. Strategy Guideline: Energy Retrofits for Low-Rise Multifamily Buildings in Cold Climates

    SciTech Connect (OSTI)

    Frozyna, K.; Badger, L.

    2013-04-01

    This Strategy Guideline explains the benefits of evaluating and identifying energy efficiency retrofit measures that could be made during renovation and maintenance of multifamily buildings. It focuses on low-rise multifamily structures (three or fewer stories) in a cold climate. These benefits lie primarily in reduced energy use, lower operating and maintenance costs, improved durability of the structure, and increased occupant comfort. This guideline focuses on retrofit measures for roof repair or replacement, exterior wall repair or gut rehab, and eating system maintenance. All buildings are assumed to have a flat ceiling and a trussed roof, wood- or steel-framed exterior walls, and one or more single or staged boilers. Estimated energy savings realized from the retrofits will vary, depending on the size and condition of the building, the extent of efficiency improvements, the efficiency of the heating equipment, the cost and type of fuel, and the climate location.

  4. Ground Source Heat Pump Sub-Slab Heat Exchange Loop Performance in a Cold Climate

    SciTech Connect (OSTI)

    Mittereder, Nick; Poerschke, Andrew

    2013-11-01

    This report presents a cold-climate project that examines an alternative approach to ground source heat pump (GSHP) ground loop design. The innovative ground loop design is an attempt to reduce the installed cost of the ground loop heat exchange portion of the system by containing the entire ground loop within the excavated location beneath the basement slab. Prior to the installation and operation of the sub-slab heat exchanger, energy modeling using TRNSYS software and concurrent design efforts were performed to determine the size and orientation of the system. One key parameter in the design is the installation of the GSHP in a low-load home, which considerably reduces the needed capacity of the ground loop heat exchanger. This report analyzes data from two cooling seasons and one heating season.

  5. Phase-mixing of Langmuir oscillations in cold electron-positron-ion plasmas

    SciTech Connect (OSTI)

    Maity, Chandan

    2014-07-15

    Space-time evolution of Langmuir oscillations in a cold homogeneous electron-positron-ion plasma has been analyzed by employing a straightforward perturbation expansion method, showing phase-mixing and, thus, wave-breaking of excited oscillations at arbitrary amplitudes. Within an assumption of infinitely massive ions, an approximate phase-mixing time is found to scale as ?{sub pe}t{sub mix}?[(6/?{sup 2})((2??){sup 5/2}/(1??))]{sup 1/3}, where ? and ? (= n{sub 0i}/n{sub 0e}) are the amplitude of perturbation and the ratio of equilibrium ion density to equilibrium electron density, respectively, and ?{sub pe}??(4?n{sub 0e}e{sup 2}/m) is the electron plasma frequency. The results presented on phase-mixing of Langmuir modes in multispecies plasmas are expected to be relevant to laboratory and astrophysical environments.

  6. Diagnostic constraints on the amount of cold mass in imploded argon pinches on Z

    SciTech Connect (OSTI)

    Apruzese, J. P.; Jones, B.; Harvey-Thompson, A. J.; Ampleford, D. J.; Jennings, C. A.; Hansen, S. B.; Moore, N. W.; Lamppa, D. C.; Coverdale, C. A.; Cuneo, M. E.; Rochau, G. A.; Giuliani, J. L.; Ouart, N. D.; Thornhill, J. W.

    2014-12-15

    The refurbished Z machine at Sandia National Laboratories has been successfully configured to drive gas-puff Z pinches. A series of experiments using Ar loads produced K-shell yields of 330 9% kJ, with highly reproducible K-shell spectra and power pulses. Using spectroscopic and power data, we are able to constrain the properties of both the cold, non-K-shell radiating mass as well as the hot K-shell component of the pinch plasma. As in previous gas-puff shots on the original version of Z, only about 1/4 to 1/3 of the load mass was heated to temperatures sufficient to produce K-shell x-rays.

  7. Cold adaptation of the mononuclear molybdoenzyme periplasmic nitrate reductase from the Antarctic bacterium Shewanella gelidimarina

    SciTech Connect (OSTI)

    Simpson, Philippa J.L.; Codd, Rachel; School of Medical Sciences and Bosch Institute, University of New South Wales, New South Wales 2006

    2011-11-04

    Highlights: Black-Right-Pointing-Pointer Cold-adapted phenotype of NapA from the Antarctic bacterium Shewanella gelidimarina. Black-Right-Pointing-Pointer Protein homology model of NapA from S. gelidimarina and mesophilic homologue. Black-Right-Pointing-Pointer Six amino acid residues identified as lead candidates governing NapA cold adaptation. Black-Right-Pointing-Pointer Molecular-level understanding of designing cool-temperature in situ oxyanion sensors. -- Abstract: The reduction of nitrate to nitrite is catalysed in bacteria by periplasmic nitrate reductase (Nap) which describes a system of variable protein subunits encoded by the nap operon. Nitrate reduction occurs in the NapA subunit, which contains a bis-molybdopterin guanine dinucleotide (Mo-MGD) cofactor and one [4Fe-4S] iron-sulfur cluster. The activity of periplasmic nitrate reductase (Nap) isolated as native protein from the cold-adapted (psychrophilic) Antarctic bacterium Shewanella gelidimarina (Nap{sub Sgel}) and middle-temperature adapted (mesophilic) Shewanella putrefaciens (Nap{sub Sput}) was examined at varied temperature. Irreversible deactivation of Nap{sub Sgel} and Nap{sub Sput} occurred at 54.5 and 65 Degree-Sign C, respectively. When Nap{sub Sgel} was preincubated at 21-70 Degree-Sign C for 30 min, the room-temperature nitrate reductase activity was maximal and invariant between 21 and 54 Degree-Sign C, which suggested that Nap{sub Sgel} was poised for optimal catalysis at modest temperatures and, unlike Nap{sub Sput}, did not benefit from thermally-induced refolding. At 20 Degree-Sign C, Nap{sub Sgel} reduced selenate at 16% of the rate of nitrate reduction. Nap{sub Sput} did not reduce selenate. Sequence alignment showed 46 amino acid residue substitutions in Nap{sub Sgel} that were conserved in NapA from mesophilic Shewanella, Rhodobacter and Escherichia species and could be associated with the Nap{sub Sgel} cold-adapted phenotype. Protein homology modeling of Nap{sub Sgel} using a mesophilic template with 66% amino acid identity showed the majority of substitutions occurred at the protein surface distal to the Mo-MGD cofactor. Two mesophilic {r_reversible} psychrophilic substitutions (Asn {r_reversible} His, Val {r_reversible} Trp) occurred in a region close to the surface of the NapA substrate funnel resulting in potential interdomain {pi}-{pi} and/or cation-{pi} interactions. Three mesophilic {r_reversible} psychrophilic substitutions occurred within 4.5 A of the Mo-MGD cofactor (Phe {r_reversible} Met, Ala {r_reversible} Ser, Ser {r_reversible} Thr) resulting in local regions that varied in hydrophobicity and hydrogen bonding networks. These results contribute to the understanding of thermal protein adaptation in a redox-active mononuclear molybdenum enzyme and have implications in optimizing the design of low-temperature environmental biosensors.

  8. Cold Crucible Induction Melter Studies for Making Glass Ceramic Waste Forms: A Feasibility Assessment

    SciTech Connect (OSTI)

    Crum, Jarrod V.; Maio, Vincent; McCloy, John S.; Scott, Clark; Riley, Brian J.; Benefiel, Bradley; Vienna, John D.; Archibald, Kip; Rodriguez, Carmen P.; Rutledge, Veronica; Zhu, Zihua; Ryan, Joseph V.; Olszta, Matthew J.

    2014-01-01

    Glass ceramics are being developed to immobilize fission products, separated from used nuclear fuel by aqueous reprocessing, into a stable waste form suitable for disposal in a geological repository. This work documents the glass ceramic formulation at bench scale and for a scaled melter test performed in a pilot-scale (~1/4 scale) cold crucible induction meter (CCIM). Melt viscosity, electrical conductivity, and crystallization behavior upon cooling were measured on a small set of compositions to select a formulation for melter testing. Property measurements also identified a temperature range for melter operation and cooling profiles necessary to crystallize the targeted phases in the waste form. Bench scale and melter run results successfully demonstrate the processability of the glass ceramic using the CCIM melter technology.

  9. Cold crucible induction melter studies for making glass ceramic waste forms: A feasibility assessment

    SciTech Connect (OSTI)

    Crum, Jarrod; Maio, Vince; McCloy, John; Scott, Clark; Riley, Brian; Benefiel, Brad; Vienna, John; Archibald, Kip; Rodriguez, Carmen; Rutledge, Veronica; Zhu, Zihua; Ryan, Joe; Olszta, Matthew

    2014-01-01

    Glass ceramics are being developed to immobilize fission products, separated from used nuclear fuel by aqueous reprocessing, into a stable waste form suitable for disposal in a geological repository. This work documents the glass ceramic formulation at bench scale and for a scaled melter test performed in a pilot-scale (approximately 1/4 scale) cold crucible induction melter (CCIM). Melt viscosity, electrical conductivity, and crystallization behavior upon cooling were measured on a small set of compositions to select a formulation for melter testing. Property measurements also identified a temperature range for melter operation and cooling profiles necessary to crystallize the targeted phases in the waste form. Bench scale and melter run results successfully demonstrate the processability of the glass ceramic using the CCIM melter technology.

  10. Insights into Cold Water Injection Stimulation Effects through Analytical Solutions to Flow and Heat Transport

    SciTech Connect (OSTI)

    M.A. Plummer

    2013-09-01

    Wells in traditional hydrothermal reservoirs are used to extract heat and to dispose of cooled water. In the first case, high productivity (the ratio of production flow rate to the pressure differential required to produce that rate) to is preferred in order to maximize power generation, while minimizing the parasitic energy loss of pumping. In the second case, high injectivity (the ratio of injection flow rate to the pressure differential required to produce that rate) is preferred, in order to reduce pumping costs. In order to improve productivity or injectivity, cold water is sometimes injected into the reservoir in an attempt to cool and contract the surrounding rock matrix and thereby induce dilation and/or extension of existing fractures or to generate new fractures. Though the increases in permeability associated with these changes are likely localized, by improving connectivity to more extensive high-permeability fractures they can at least temporarily provide substantially improved productivity or injectivity.

  11. Cold Climate Foundation Retrofit Experimental Hygrothermal Performance. Cloquet Residential Research Facility Laboratory Results

    SciTech Connect (OSTI)

    Goldberg, Louise F.; Harmon, Anna C.

    2015-04-09

    This project was funded jointly by the National Renewable Energy Laboratory (NREL) and Oak Ridge National Laboratory (ORNL). ORNL focused on developing a full basement wall system experimental database to enable others to validate hygrothermal simulation codes. NREL focused on testing the moisture durability of practical basement wall interior insulation retrofit solutions for cold climates. The project has produced a physically credible and reliable long-term hygrothermal performance database for retrofit foundation wall insulation systems in zone 6 and 7 climates that are fully compliant with the performance criteria in the 2009 Minnesota Energy Code. These data currently span the period from November 10, 2012 through May 31, 2014 and are anticipated to be extended through November 2014. The experimental data were configured into a standard format that can be published online and that is compatible with standard commercially available spreadsheet and database software.

  12. Volatilization of heavy metals and radionuclides from soil heated in an induction ``cold`` crucible melter

    SciTech Connect (OSTI)

    Aloy, A.S.; Belov, V.Z.; Trofimenko, A.S. [Khlopin Radium Inst., St. Petersburg (Russian Federation); Dmitriev, S.A.; Stefanovsky, S.V. [SIA Radon, Moscow (Russian Federation); Gombert, D.; Knecht, D.A. [Lockheed Martin Idaho Technologies Co., Idaho Falls, ID (United States)

    1997-12-31

    The behavior of heavy metals and radionuclides during high-temperature treatment is very important for the design and operational capabilities of the off-gas treatment system, as well as for a better understanding of the nature and forms of the secondary waste. In Russia, a process for high-temperature melting in an induction heated cold crucible system is being studied for vitrification of Low Level Waste (LLW) flyash and SYNROC production with simulated high level waste (HLW). This work was done as part of a Department of Energy (DOE) funded research project for thermal treatment of mixed low level waste (LLW). Soil spiked with heavy metals (Cd, Pb) and radionuclides (Cs-137, U-239, Pu-239) was used as a waste surrogate. The soil was melted in an experimental lab-scale system that consisted of a high-frequency generator (1.76 MHz, 60 kW), a cold crucible melter (300 mm high and 90 mm in diameter), a shield box, and an off-gas system. The process temperature was 1,350--1,400 C. Graphite and silicon carbide were used as sacrificial conductive materials to start heating and initial melting of the soil batch. The off-gas system was designed in such a manner that after each experiment, it can be disconnected to collect and analyze all deposits to determine the mass balance. The off-gases were also sampled during an experiment to analyze for hydrogen, NO{sub x}, carbon dioxide, carbon monoxide and chlorine formation. This paper describes distribution and mass balance of metals and radionuclides in various parts of the off-gas system. The leach rate of the solidified blocks identified by the PCT method is also reported.

  13. Applying the cold plasma dispersion relation to whistler mode chorus waves: EMFISIS wave measurements from the Van Allen Probes

    SciTech Connect (OSTI)

    Hartley, D. P.; Chen, Y.; Kletzing, C. A.; Denton, M. H.; Kurth, W. S.

    2015-02-17

    Most theoretical wave models require the power in the wave magnetic field in order to determine the effect of chorus waves on radiation belt electrons. However, researchers typically use the cold plasma dispersion relation to approximate the magnetic wave power when only electric field data are available. In this study, the validity of using the cold plasma dispersion relation in this context is tested using Electric and Magnetic Field Instrument Suite and Integrated Science (EMFISIS) observations of both the electric and magnetic spectral intensities in the chorus wave band (0.10.9 fce). Results from this study indicate that the calculated wave intensity is least accurate during periods of enhanced wave activity. For observed wave intensities >10? nT, using the cold plasma dispersion relation results in an underestimate of the wave intensity by a factor of 2 or greater 56% of the time over the full chorus wave band, 60% of the time for lower band chorus, and 59% of the time for upper band chorus. Hence, during active periods, empirical chorus wave models that are reliant on the cold plasma dispersion relation will underestimate chorus wave intensities to a significant degree, thus causing questionable calculation of wave-particle resonance effects on MeV electrons.

  14. Precursors to cold fusion phenomenon and the detection of energetic charged particles in deuterium/solid systems

    SciTech Connect (OSTI)

    Dong, S.Y.; Wang, K.L.; Feng, Y.Y.; Chang, L.; Luo, C.M.; Hu, R.Y.; Zhou, P.L.; Mo, D.W.; Zhu, Y.F.; Song, C.L.; Chen, Y.T.; Yao, M.Y.; Ren, C.; Chen, Q.K.; Li, X.Z. )

    1991-11-01

    A precursor to the cold fusion phenomenon in deuterium/solid systems is sought in order to solve the problem of reproducibility. The results of the first experiments are discussed. Electromagnetic radiation and energetic charged particles have been detected. In this paper it is shown that the surface condition has an important effect on this phenomenon.

  15. Neutron-halo nuclei in cold synthesis and cluster decay of heavy nuclei: {ital Z}=104 nucleus as an example

    SciTech Connect (OSTI)

    Gupta, R.K.; Singh, S.; Muenzenberg, G.; Scheid, W.

    1995-05-01

    Nuclei at the neutron-drip line are studied. The light neutron-halo nuclei are found to play an important role for both cold fusion reactions and exotic cluster decay studies of heavy nuclei at the neutron-drip line. For cold fusion reactions, beams of neutron-halo nuclei are shown to occur as natural extensions of the conventional lighter beams but with the corresponding target nuclei as the heavy neutron-rich radioactive nuclei. Thus, in synthesizing the various isotopes of a neutron-rich cool compound nucleus, both the target and projectile nuclei have to be richer in neutrons, with their proton numbers remaining the same. On the other hand, neutron-halo (cluster) decays are favored for a relatively less neutron-rich parent nucleus. Possible consequences of this work for the shell structure effects in neutron-rich heavy nuclei are also pointed out. This follows from the fact that the so far observed phenomena of both cold fusion and cluster radioactivity are associated with closed or nearly closed shell nuclei. Calculations are made for {sup 274,288}104, using the quantum mechanical fragmentation theory for cold fusion reaction studies and a performed cluster model for cluster decay studies.

  16. DOE ACHIEVES MAJOR COLD WAR LEGACY WASTE CLEANUP MILESTONE: Waste Isolation Pilot Plant Receives 10,000th Shipment

    Broader source: Energy.gov [DOE]

    CARLSBAD, N.M. – The Waste Isolation Pilot Plant (WIPP) received its 10,000th shipment of transuranic (TRU) waste on Sept. 24, 2011. This marked an important milestone in the DOE Office of Environmental Management mission to clean up the country’s Cold War legacy.

  17. Molecular biology of Homo sapiens: Abstracts of papers presented at the 51st Cold Spring Harbor symposium on quantitative biology

    SciTech Connect (OSTI)

    Watson, J.D.; Siniscalco, M.

    1986-01-01

    This volume contains abstracts of papers presented at the 51st Cold Springs Harbor Symposium on Quantitative Biology. The topic for this meeting was the ''Molecular Biology of Homo sapiens.'' Sessions were entitled Human Gene Map, Human Cancer Genes, Genetic Diagnosis, Human Evolution, Drugs Made Off Human Genes, Receptors, and Gene Therapy. (DT)

  18. Applying the cold plasma dispersion relation to whistler mode chorus waves: EMFISIS wave measurements from the Van Allen Probes

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Hartley, D. P.; Chen, Y.; Kletzing, C. A.; Denton, M. H.; Kurth, W. S.

    2015-02-17

    Most theoretical wave models require the power in the wave magnetic field in order to determine the effect of chorus waves on radiation belt electrons. However, researchers typically use the cold plasma dispersion relation to approximate the magnetic wave power when only electric field data are available. In this study, the validity of using the cold plasma dispersion relation in this context is tested using Electric and Magnetic Field Instrument Suite and Integrated Science (EMFISIS) observations of both the electric and magnetic spectral intensities in the chorus wave band (0.1–0.9 fce). Results from this study indicate that the calculated wavemore » intensity is least accurate during periods of enhanced wave activity. For observed wave intensities >10⁻³ nT², using the cold plasma dispersion relation results in an underestimate of the wave intensity by a factor of 2 or greater 56% of the time over the full chorus wave band, 60% of the time for lower band chorus, and 59% of the time for upper band chorus. Hence, during active periods, empirical chorus wave models that are reliant on the cold plasma dispersion relation will underestimate chorus wave intensities to a significant degree, thus causing questionable calculation of wave-particle resonance effects on MeV electrons.« less

  19. Creep-Rupture Behavior and Recrystallization in HR6W and Haynes Alloy 230 Cold-Bent Boiler Tubing for Ultrasupercritical (USC) Steam Boiler Applications

    SciTech Connect (OSTI)

    Shingledecker, John P

    2007-01-01

    Creep-rupture experiments were conducted on HR6W and Haynes 230, candidate Ultrasupercritical (USC) alloys, tubes to evaluate the effects of cold-work and recrystallization during high-temperature service. These creep tests were performed by internally pressurizing cold-bent boiler tubes at 775 C for times up to 8000 hours. The bends were fabricated with cold-work levels beyond the current ASME Boiler and Pressure Vessel (ASME B&PV) Code Section I limits for austenitic stainless steels. Destructive metallographic evaluation of the crept tube bends was used to determine the effects of cold-work and the degree of recrystallization. The metallographic analysis combined with an evaluation of the creep and rupture data suggest that solid-solution strengthened nickel-based alloys can be fabricated for high-temperature service at USC conditions utilizing levels of cold-work higher than the current allowed levels for austenitic stainless steels.

  20. Investigation of cold fusion phenomena in deuterated metals. Final report, Volume 1. Overview, executive summary, chemistry, physics, gas reactions, metallurgy. Technical information series

    SciTech Connect (OSTI)

    Anderson, L.; Barrowes, S.C.; Bergeson, H.E.; Bourgeois, F.; Cedzynska, K.

    1991-06-01

    The March 1989 announcement by Pons and Fleischmann stimulated worldwide interest in the cold fusion phenomenon. In Utah the legislature appropriated $5 million to support cold fusion research and development. As cold fusion inquiries continue worldwide, this interim report has been written to document the scientific and legal work that has been funded by the Utah legislature. Partial contents include these titles of papers: Cold Fusion Studies in a High-Pressure Sealed Cell; Tritium and Neutron Generation in Palladium Cathodes with High Deuterium Loading; Deuterium-Gas Phase Reactions on Palladium; Excess Heat Estimation with the Kalman Filter; Ultrasonic Energy Effects on Palladium Electrodes in Cold Fusion Cells; Nuclear Measurements on Deuterium-Loaded Palladium and Titanium.

  1. Fusion by diffusion. II. Synthesis of transfermium elements in cold fusion reactions

    SciTech Connect (OSTI)

    Swiatecki, W.J.; Siwek-Wilczynska, K.; Wilczynski, J.

    2005-01-01

    We describe a method of estimating cross sections for the synthesis of very heavy nuclei by the fusion of two lighter ones. The cross section is considered to be the product of three factors: the cross section for the projectile to overcome the Coulomb barrier, the probability that the resulting composite nucleus reaches the compound nucleus configuration by a shape fluctuation treated as a diffusion of probability in one dimension, and the probability that the excited compound nucleus survives fission. Semi-empirical formulas for the mean Coulomb barrier height and its distribution around the mean are constructed. After overcoming the Coulomb barrier the system is assumed to be injected into an 'asymmetric fission valley' by a rapid growth of the neck between the target and projectile at approximately frozen asymmetry and elongation. Diffusion in the elongation coordinate in this valley can occasionally bring the system over the saddle separating the injection point from the compound nucleus configuration. This is the stage that accounts for the hindrance to fusion observed for very heavy reacting systems. The competition between deexcitation of the compound nucleus by neutron emission and fission is treated by standard methods, but an interesting insight allows one to predict in an elementary way the location of the maximum in the resulting excitation function. Adjusting one parameter in the theory causes the calculated peak cross sections to agree within about a factor of 2 or so with 12 measured or estimated values for 'cold' one-neutron-out reactions where targets of {sup 208}Pb and {sup 209}Bi are bombarded with projectiles ranging from {sup 48}Ca to {sup 70}Zn. The centroids of the excitation functions agree with theory to within 1 or 2 MeV for the six cases where they have been determined, and their widths are reproduced. 'Hot' fusion reactions, where several neutrons are emitted, are not treated, except that a comparison is made between the hindrance factors in cold and hot reactions to make elements with atomic numbers 112 to 118. The calculated diffusive hindrances in the hot reactions are less unfavorable by 4 to 5 orders of magnitude.

  2. Mid-infrared followup of cold brown dwarfs: diversity in age, mass and metallicity

    SciTech Connect (OSTI)

    Saumon, Didier; Leggett, Sandy K; Burningham, Ben; Marley, Mark S; Waren, S J; Jones, H R A; Pinfield, D J; Smart, R L

    2009-01-01

    We present new Spitzer IRAC [3.6], [4.5], [5.8] and [8.0] photometry of nine very late-type T dwarfs. Combining this with previously published photometry, we investigate trends with type and color that are useful for both the planning and interpretation of infrared surveys designed to discover the coldest T or Y dwarfs. Brown dwarfs with effective temperature (T{sub eff}) below 700 K emit more than half their flux at wavelengths longer than 3 {micro}m, and the ratio of the mid-infrared flux to the near-infrared flux becomes very sensitive to T{sub eff} at these low temperatures. We confirm that the color H (1.6 {micro}m) - [4.5] is a good indicator of T{sub eff} with a relatively weak dependence on metallicity and gravity. Conversely, the colors H - K (2.2 {micro}m) and [4.5] - [5.8] are sensitive to metallicity and gravity. Thus near- and mid-infrared photometry provide useful indicators of the fundamental properties of brown dwarfs, and if temperature and gravity are known, then mass and age can be reliably determined from evolutionary models. There are twelve dwarfs currently known with H - [4.5] > 3.0, and {approx} 500 < T{sub eff} K {approx}< 800, which we examine in detail. The ages of the dwarfs in the sample range from very young (0.1 - 1.0 Gyr) to relatively old (3 - 12 Gyr). The mass range is possibly as low as 5 Jupiter masses to up to 70 Jupiter masses, i.e. near the hydrogen burning limit. The metallicities also span a large range, from [m/H]= -0.3 to [m/H]= +0.2. The small number of T8 - T9 dwarfs found in the UKIRT Infrared Deep Sky Survey to date appear to be predominantly young low-mass dwarfs. Accurate mid-infrared photometry of cold brown dwarfs is essentially impossible from the ground, and extensions to the mid-infrared space missions warm-Spitzer and WISE are desirable in order to obtain the vital mid-infrared data for cold brown dwarfs, and to discover more of these rare objects.

  3. HERSCHEL's ''COLD DEBRIS DISKS'': BACKGROUND GALAXIES OR QUIESCENT RIMS OF PLANETARY SYSTEMS?

    SciTech Connect (OSTI)

    Krivov, A. V.; Loehne, T.; Mutschke, H.; Neuhaeuser, R. [Astrophysikalisches Institut und Universitaetssternwarte, Friedrich-Schiller-Universitaet Jena, Schillergaesschen 2-3, D-07745 Jena (Germany); Eiroa, C.; Marshall, J. P.; Mustill, A. J. [Departamento de Fisica Teorica, Facultad de Ciencias, Universidad Autonoma de Madrid, Cantoblanco, E-28049 Madrid (Spain); Montesinos, B. [Departamento de Astrofisica, Centro de Astrobiologia (CAB, CSIC-INTA), ESAC Campus, P.O. Box 78, E-28691 Villanueva de la Canada, Madrid (Spain); Del Burgo, C. [Instituto Nacional de Astrofisica, Optica y Electronica (INAOE), Apartado Postal 51 y 216, 72000 Puebla, Pue. (Mexico); Absil, O. [Institut d'Astrophysique et de Geophysique, Universite de Liege, Allee du 6 Aout 17, B-4000 Liege (Belgium); Ardila, D. [NASA Herschel Science Center, California Institute of Technology, 1200 East California Boulevard, Pasadena, CA 91125 (United States); Augereau, J.-C.; Ertel, S.; Lebreton, J. [UJF-Grenoble 1/CNRS-INSU, Institut de Planetologie et d'Astrophysique de Grenoble (IPAG), UMR 5274, F-38041 Grenoble (France); Bayo, A. [European Southern Observatory, Alonso de Cordova 3107, Vitacura, Santiago (Chile); Bryden, G. [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109 (United States); Danchi, W. [NASA Goddard Space Flight Center, Exoplanets and Stellar Astrophysics, Code 667, Greenbelt, MD 20771 (United States); Liseau, R. [Department of Earth and Space Sciences, Chalmers University of Technology, Onsala Space Observatory, SE-43992, Onsala (Sweden); Mora, A. [ESA-ESAC Gaia SOC, P.O. Box 78, E-28691 Villanueva de la Canada, Madrid (Spain); Pilbratt, G. L., E-mail: krivov@astro.uni-jena.de [ESA Astrophysics and Fundamental Physics Missions Division, ESTEC/SRE-SA, Keplerlaan 1, 2201 AZ Noordwijk (Netherlands); and others

    2013-07-20

    Infrared excesses associated with debris disk host stars detected so far peak at wavelengths around {approx}100 {mu}m or shorter. However, 6 out of 31 excess sources studied in the Herschel Open Time Key Programme, DUNES, have been seen to show significant-and in some cases extended-excess emission at 160 {mu}m, which is larger than the 100 {mu}m excess. This excess emission has been attributed to circumstellar dust and has been suggested to stem from debris disks colder than those known previously. Since the excess emission of the cold disk candidates is extremely weak, challenging even the unrivaled sensitivity of Herschel, it is prudent to carefully consider whether some or even all of them may represent unrelated galactic or extragalactic emission, or even instrumental noise. We re-address these issues using several distinct methods and conclude that it is highly unlikely that none of the candidates represents a true circumstellar disk. For true disks, both the dust temperatures inferred from the spectral energy distributions and the disk radii estimated from the images suggest that the dust is nearly as cold as a blackbody. This requires the grains to be larger than {approx}100 {mu}m, even if they are rich in ices or are composed of any other material with a low absorption in the visible. The dearth of small grains is puzzling, since collisional models of debris disks predict that grains of all sizes down to several times the radiation pressure blowout limit should be present. We explore several conceivable scenarios: transport-dominated disks, disks of low dynamical excitation, and disks of unstirred primordial macroscopic grains. Our qualitative analysis and collisional simulations rule out the first two of these scenarios, but show the feasibility of the third one. We show that such disks can indeed survive for gigayears, largely preserving the primordial size distribution. They should be composed of macroscopic solids larger than millimeters, but smaller than a few kilometers in size. If larger planetesimals were present, then they would stir the disk, triggering a collisional cascade and thus causing production of small debris, which is not seen. Thus, planetesimal formation, at least in the outer regions of the systems, has stopped before 'cometary' or 'asteroidal' sizes were reached.

  4. Historical collection of preprints, reprints, working papers, correspondence, and other documents related to the "cold fusion" experiments conducted by Stanley Pons and Martin Fleischmann.

    SciTech Connect (OSTI)

    2013-04-01

    This historical collection consists of various letters, correspondence, working papers, reprints, preprints, workshop reports, and news clippings related to the "cold fusion" experiments conducted by Stanley Pons and Martin Fleischmann. Binders and contents. 1. Laboratory Reprints/Preprints (Laboratory Documents from 9 national Labs. Some original documents); 2. Summary Report by Dr. Duane L. Barney (Articles, Letters, and Reports through 1994 on Cold Fusion. Original Documents); 3. Conference Workshops (Official Documents, schedules, and notes from 4 conferences); 4. HSS&T Hearings, SRI Incident Jan. 1992 (Summary of Cold Fusion Research and reports following SRI Incident. Original Documents); 5. Media 1989 to Present (circa 1995) (Journals, Magazines, Newspapers, and Press Releases from 1989-1995. Some reprints, some original articles/magazines); 6. Science in Service of National Economy aka Manfred's Book (A comprehensive overview of various research being done at Laboratories across the country that could impact the economy); 7. ERAB Information (Comprehensive Report on Cold Fusion Research w/ recommendations on funding and continued research. Original documents); 8. Misc.: Memorandum, Notes, Reports, Summaries, and Updates Chronologically 1989 (Various documents related to Cold Fusion in order of print from 1989. Original documents); 9. Misc.: Memorandum, Notes, Reports, Summaries, and Updates Chronologically 1990-1992 (Various documents related to Cold Fusion including status reports and research in order of print from 1990-1992. Original documents); 10. Misc.: Memorandum, Notes, Reports, Summaries, and Updates Chronologically 1993-1995 (Various documents related to Cold Fusion including status reports and research in order of print from 1993-1995. Original documents); 11. General: Preprints/Reprints Filed by Institution A-H (Reports of Research and Conclusion from various universities and institutions.); 12. General: Preprints/Reprints Filed by Institution I-R (Reports of Research and Conclusion from various universities and institutions.); 13. General: Preprints/Reprints Filed by Institution S-Z (Reports of Research and Conclusion from various universities and institutions.); 14. General: Correspondence, Incoming, Inquiries A-F (Letters, Correspondence, and Inquiries regarding Cold Fusion and its research. Sorted by Last Name of Author. Original documents); 15. General: Correspondence, Incoming, Inquiries G-L (Letters, Correspondence, and Inquiries regarding Cold Fusion and its research. Sorted by Last Name of Author. Original documents); 16. General: Correspondence, Incoming, Inquiries M-R (Letters, Correspondence, and Inquiries regarding Cold Fusion and its research. Sorted by Last Name of Author. Original documents); 17. General: Correspondence, Incoming, Inquiries S-Z (Letters, Correspondence, and Inquiries regarding Cold Fusion and its research. Sorted by Last Name of Author. Original documents); 18. Miscellaneous papers (Investigation of Cold Fusion Phenomena in Deuterated Metals-NCFI Final Report Volumes I. II, and III; June 1991; 4th Annual Conference on Cold Fusion Proceedings: Volumes 1-4; Development of Advanced Concepts for Nuclear Processes in Deuterated Metals; A Comprehensive Report on the research methods, background information, and principles related to Cold Fusion; Cold Fusion Research: November 1989; ERAB report on Cold Fusion Research; Proceedings: Workshop on Anomalous Effects in Deuterided Metals; Workshop designed to generate audio between skeptics and advocates to examine Cold Fusion research results and remaining questions in research methods; Muon Catalyzed Fusion; Overview of Muon Catalyzed Fusion; Grant Application for Cold Fusion Research; Original application to DOE from Prof. Pons that was withdrawn in favor of a new grant proposal).

  5. Airflow reduction during cold weather operation of residential heat recovery ventilators

    SciTech Connect (OSTI)

    McGugan, C.A.; Edwards, P.F.; Riley, M.A.

    1987-06-01

    Laboratory measurements of the performance of residential heat recovery ventilators have been carried out for the R-2000 Energy Efficient Home Program. This work was based on a preliminary test procedure developed by the Canadian Standards Association, part of which calls for testing the HRV under cold weather conditions. An environmental chamber was used to simulate outdoor conditions. Initial tests were carried out with an outdoor temperature of -20/sup 0/C; subsequent tests were carried out at a temperature of -25/sup 0/C. During the tests, airflows, temperatures, and relative humidities of airstreams entering and leaving the HRV, along with electric power inputs, were monitored. Frost buildup in the heat exchangers and defrost mechanisms, such as fan shutoff or recirculation, led to reductions in airflows. The magnitude of the reductions is dependent on the design of the heat exchanger and the defrost mechanism used. This paper presents the results of tests performed on a number of HRVs commercially available in Canada at the time of the testing. The flow reductions for the various defrost mechanisms are discussed.

  6. Cold black holes in the HarlowHayden approach to firewalls

    SciTech Connect (OSTI)

    Ong, Yen Chin; McInnes, Brett; Chen, Pisin

    2014-12-31

    Firewalls are controversial principally because they seem to imply departures from general relativistic expectations in regions of spacetime where the curvature need not be particularly large. One of the virtues of the HarlowHayden approach to the firewall paradox, concerning the time available for decoding of Hawking radiation emanating from charged AdS black holes, is precisely that it operates in the context of cold black holes, which are not strongly curved outside the event horizon. Here we clarify this point. The approach is based on ideas borrowed from applications of the AdS/CFT correspondence to the quarkgluon plasma. Firewalls aside, our work presents a detailed analysis of the thermodynamics and evolution of evaporating charged AdS black holes with flat event horizons. We show that, in one way or another, these black holes are always eventually destroyed in a time which, while long by normal standards, is short relative to the decoding time of Hawking radiation.

  7. Insulated Concrete Form Walls Integrated With Mechanical Systems in a Cold Climate Test House

    SciTech Connect (OSTI)

    Mallay, D.; Wiehagen, J.

    2014-09-01

    Transitioning from standard light frame to a thermal mass wall system in a high performance home will require a higher level of design integration with the mechanical systems. The much higher mass in the ICF wall influences heat transfer through the wall and affects how the heating and cooling system responds to changing outdoor conditions. This is even more important for efficient, low-load homes with efficient heat pump systems in colder climates where the heating and cooling peak loads are significantly different from standard construction. This report analyzes a range of design features and component performance estimates in an effort to select practical, cost-effective solutions for high performance homes in a cold climate. Of primary interest is the influence of the ICF walls on developing an effective air sealing strategy and selecting an appropriate heating and cooling equipment type and capacity. The domestic water heating system is analyzed for costs and savings to investigate options for higher efficiency electric water heating. A method to ensure mechanical ventilation air flows is examined. The final solution package includes high-R mass walls, very low infiltration rates, multi-stage heat pump heating, solar thermal domestic hot water system, and energy recovery ventilation. This solution package can be used for homes to exceed 2012 International Energy Conservation Code requirements throughout all climate zones and achieves the DOE Challenge Home certification.

  8. Ground Source Heat Pump Sub-Slab Heat Exchange Loop Performance in a Cold Climate

    SciTech Connect (OSTI)

    Mittereder, N.; Poerschke, A.

    2013-11-01

    This report presents a cold-climate project that examines an alternative approach to ground source heat pump (GSHP) ground loop design. The innovative ground loop design is an attempt to reduce the installed cost of the ground loop heat exchange portion of the system by containing the entire ground loop within the excavated location beneath the basement slab. Prior to the installation and operation of the sub-slab heat exchanger, energy modeling using TRNSYS software and concurrent design efforts were performed to determine the size and orientation of the system. One key parameter in the design is the installation of the GSHP in a low-load home, which considerably reduces the needed capacity of the ground loop heat exchanger. This report analyzes data from two cooling seasons and one heating season. Upon completion of the monitoring phase, measurements revealed that the initial TRNSYS simulated horizontal sub-slab ground loop heat exchanger fluid temperatures and heat transfer rates differed from the measured values. To determine the cause of this discrepancy, an updated model was developed utilizing a new TRNSYS subroutine for simulating sub-slab heat exchangers. Measurements of fluid temperature, soil temperature, and heat transfer were used to validate the updated model.

  9. OMEGA: A NEW COLD X-RAY SIMULATION FACILITY FOR THE EVALUATION OF OPTICAL COATINGS

    SciTech Connect (OSTI)

    Fisher, J H; Newlander, C D; Fournier, K B; Beutler, D E; Coverdale, C A; May, M J; Tobin, M; Davis, J F; Shiekh, D

    2007-04-27

    We report on recent progress for the development of a new cold X-ray optical test capability using the Omega Facility located at the Laboratory for Laser Energetics (LLE) at the University of Rochester. These tests were done on the 30 kJ OMEGA laser at the Laboratory for Laser Energetics (LLE) at the University of Rochester, Rochester, NY. We conducted a six-shot series called OMEGA II on 14 July 2006 in one eight-hour day (supported by the Defense Threat Reduction Agency). The initial testing was performed using simple protected gold optical coatings on fused silica substrates. PUFFTFT analyses were completed and the specimen's thermal lateral stress and transverse stress conditions were calculated and interpreted. No major anomalies were detected. Comparison of the pre- and posttest reflective measurements coupled with the TFCALC analyses proved invaluable in guiding the analyses and interpreting the observed damage. The Omega facility is a high quality facility for performing evaluation of optical coatings and coupons and provides experience for the development of future National Ignition Facility (NIF) testing.

  10. Spent nuclear fuel project, Cold Vacuum Drying Facility human factors engineering (HFE) analysis: Results and findings

    SciTech Connect (OSTI)

    Garvin, L.J.

    1998-07-17

    This report presents the background, methodology, and findings of a human factors engineering (HFE) analysis performed in May, 1998, of the Spent Nuclear Fuels (SNF) Project Cold Vacuum Drying Facility (CVDF), to support its Preliminary Safety Analysis Report (PSAR), in responding to the requirements of Department of Energy (DOE) Order 5480.23 (DOE 1992a) and drafted to DOE-STD-3009-94 format. This HFE analysis focused on general environment, physical and computer workstations, and handling devices involved in or directly supporting the technical operations of the facility. This report makes no attempt to interpret or evaluate the safety significance of the HFE analysis findings. The HFE findings presented in this report, along with the results of the CVDF PSAR Chapter 3, Hazards and Accident Analyses, provide the technical basis for preparing the CVDF PSAR Chapter 13, Human Factors Engineering, including interpretation and disposition of findings. The findings presented in this report allow the PSAR Chapter 13 to fully respond to HFE requirements established in DOE Order 5480.23. DOE 5480.23, Nuclear Safety Analysis Reports, Section 8b(3)(n) and Attachment 1, Section-M, require that HFE be analyzed in the PSAR for the adequacy of the current design and planned construction for internal and external communications, operational aids, instrumentation and controls, environmental factors such as heat, light, and noise and that an assessment of human performance under abnormal and emergency conditions be performed (DOE 1992a).

  11. Technology Solutions Case Study: Durable Interior Foundation Insulation Retrofits for Cold Climates, Cloquet, Minnesota

    SciTech Connect (OSTI)

    2015-04-01

    Thermal and moisture problems in existing basements create a unique challenge as the exterior face of the wall is not easily or inexpensively accessible. This approach by the NorthernSTAR Building America Partnership team addresses thermal and moisture management from the interior face of the wall without disturbing the exterior soil and landscaping. It is effective at reducing energy loss through the wall principally during the heating season. The team conducted experiments at the Cloquet Residential Research Facility to test the heat and moisture performance of four hollow masonry block wall systems and two rim-joist systems. These systems were retrofitted with interior insulation in compliance with the 2012 IECC. The research showed for the first time that, for masonry block walls in a cold climate, a solid bond beam or equivalent provides adequate resistance to moisture transport from a hollow core to the rim-joist cavity. Thus, a solid top course is a minimum requirement for an interior retrofit insulation system.

  12. COLD DUST BUT WARM GAS IN THE UNUSUAL ELLIPTICAL GALAXY NGC 4125

    SciTech Connect (OSTI)

    Wilson, C. D.; Cridland, A.; Foyle, K.; Parkin, T. J.; Cooper, E. Mentuch; Roussel, H.; Sauvage, M.; Lebouteiller, V.; Madden, S.; Baes, M.; De Looze, I.; Bendo, G.; Boquien, M.; Boselli, A.; Ciesla, L.; Clements, D. L.; Cooray, A.; Galametz, M.; and others

    2013-10-20

    Data from the Herschel Space Observatory have revealed an unusual elliptical galaxy, NGC 4125, which has strong and extended submillimeter emission from cold dust but only very strict upper limits to its CO and H I emission. Depending on the dust emissivity, the total dust mass is 2-5 10{sup 6} M {sub ?}. While the neutral gas-to-dust mass ratio is extremely low (<12-30), including the ionized gas traced by [C II] emission raises this limit to <39-100. The dust emission follows a similar r {sup 1/4} profile to the stellar light and the dust to stellar mass ratio is toward the high end of what is found in nearby elliptical galaxies. We suggest that NGC 4125 is currently in an unusual phase where evolved stars produced in a merger-triggered burst of star formation are pumping large amounts of gas and dust into the interstellar medium. In this scenario, the low neutral gas-to-dust mass ratio is explained by the gas being heated to temperatures ?10{sup 4} K faster than the dust is evaporated. If galaxies like NGC 4125, where the far-infrared emission does not trace neutral gas in the usual manner, are common at higher redshift, this could have significant implications for our understanding of high redshift galaxies and galaxy evolution.

  13. A new parameter space study of the fermionic cold dark matter model

    SciTech Connect (OSTI)

    Bagherian, Z.; Ettefaghi, M.M.; Haghgouyan, Z.; Moazzemi, R. E-mail: mettefaghi@qom.ac.ir E-mail: r.moazzemi@qom.ac.ir

    2014-10-01

    We consider the standard model (SM) extended by a gauge singlet fermion as cold dark matter (SFCDM) and a gauge singlet scalar (singlet Higgs) as a mediator. The parameter space of the SM is enlarged by seven new ones. We obtain the total annihilation cross section of singlet fermions to the SM particles and singlet Higgs at tree level. Regarding the relic abundance constraint obtained by WMAP observations, we study the dependency on each parameter separately, for dark matter masses up to 1 TeV. In particular, the coupling of SFCDM to singlet Higgs g{sub s}, the SFCDM mass m{sub ψ}, the second Higgs mass m{sub h{sub 2}}, and the Higgs bosons mixing angel θ are investigated accurately. Three other parameters play no significant role. For a maximal mixing of Higgs bosons or at resonances, g{sub s} is applicable for the perturbation theory at tree level. We also obtain the scattering cross section of SFCDM off nucleons and compare our results with experiments which have already reported data in this mass range; XENON100, LUX, COUPP and PICASSO collaborations. Our results show that the SFCDM is excluded by these experiments for choosing parameters which are consistent with perturbation theory and relic abundance constraints.

  14. Fission Product Separation from Pyrochemical Electrolyte by Cold Finger Melt Crystallization

    SciTech Connect (OSTI)

    Joshua R. Versey

    2013-08-01

    This work contributes to the development of pyroprocessing technology as an economically viable means of separating used nuclear fuel from fission products and cladding materials. Electrolytic oxide reduction is used as a head-end step before electrorefining to reduce oxide fuel to metallic form. The electrolytic medium used in this technique is molten LiCl-Li2O. Groups I and II fission products, such as cesium (Cs) and strontium (Sr), have been shown to partition from the fuel into the molten LiCl-Li2O. Various approaches of separating these fission products from the salt have been investigated by different research groups. One promising approach is based on a layer crystallization method studied at the Korea Atomic Energy Research Institute (KAERI). Despite successful demonstration of this basic approach, there are questions that remain, especially concerning the development of economical and scalable operating parameters based on a comprehensive understanding of heat and mass transfer. This research explores these parameters through a series of experiments in which LiCl is purified, by concentrating CsCl in a liquid phase as purified LiCl is crystallized and removed via an argon-cooled cold finger.

  15. Characterization of Ceramic Material Produced From a Cold Crucible Induction Melter Test

    SciTech Connect (OSTI)

    Amoroso, J.; Marra, J.

    2015-04-30

    This report summarizes the results from characterization of samples from a melt processed surrogate ceramic waste form. Completed in October of 2014, the first scaled proof of principle cold crucible induction melter (CCIM) test was conducted to process a Fe-hollandite-rich titanate ceramic for treatment of high level nuclear waste. X-ray diffraction, electron microscopy, inductively coupled plasma-atomic emission spectroscopy (and inductively coupled plasma-mass spectroscopy for Cs), and product consistency tests were used to characterize the CCIM material produced. Core samples at various radial locations from the center of the CCIM were taken. These samples were also sectioned and analyzed vertically. Together, the various samples were intended to provide an indication of the homogeneity throughout the CCIM with respect to phase assemblage, chemical composition, and chemical durability. Characterization analyses confirmed that a crystalline ceramic with desirable phase assemblage was produced from a melt using a CCIM. Hollandite and zirconolite were identified in addition to possible highly-substituted pyrochlore and perovskite. Minor phases rich in Fe, Al, or Cs were also identified. Remarkably only minor differences were observed vertically or radially in the CCIM material with respect to chemical composition, phase assemblage, and durability. This recent CCIM test and the resulting characterization in conjunction with demonstrated compositional improvements support continuation of CCIM testing with an improved feed composition and improved melter system.

  16. Linking legacies: Connecting the Cold War nuclear weapons production processes to their environmental consequences

    SciTech Connect (OSTI)

    1997-01-01

    In the aftermath of the Cold War, the US has begun addressing the environmental consequences of five decades of nuclear weapons production. In support of this effort, the National Defense Authorization Act for Fiscal Year 1995 directed the Department of Energy (DOE) to describe the waste streams generated during each step in the production of nuclear weapons. Accordingly, this report responds to this mandate, and it is the Department`s first comprehensive analysis of the sources of waste and contamination generated by the production of nuclear weapons. The report also contains information on the missions and functions of nuclear weapons facilities, on the inventories of waste and materials remaining at these facilities, as well as on the extent and characteristics of contamination in and around these facilities. This analysis unites specific environmental impacts of nuclear weapons production with particular production processes. The Department used historical records to connect nuclear weapons production processes with emerging data on waste and contamination. In this way, two of the Department`s legacies--nuclear weapons manufacturing and environmental management--have become systematically linked. The goal of this report is to provide Congress, DOE program managers, non-governmental analysts, and the public with an explicit picture of the environmental results of each step in the nuclear weapons production and disposition cycle.

  17. A STATISTICAL METHOD FOR MEASURING THE GALACTIC POTENTIAL AND TESTING GRAVITY WITH COLD TIDAL STREAMS

    SciTech Connect (OSTI)

    Penarrubia, Jorge; Walker, Matthew G.

    2012-11-20

    We introduce the Minimum Entropy Method, a simple statistical technique for constraining the Milky Way gravitational potential and simultaneously testing different gravity theories directly from 6D phase-space surveys and without adopting dynamical models. We demonstrate that orbital energy distributions that are separable (i.e., independent of position) have an associated entropy that increases under wrong assumptions about the gravitational potential and/or gravity theory. Of known objects, 'cold' tidal streams from low-mass progenitors follow orbital distributions that most nearly satisfy the condition of separability. Although the orbits of tidally stripped stars are perturbed by the progenitor's self-gravity, systematic variations of the energy distribution can be quantified in terms of the cross-entropy of individual tails, giving further sensitivity to theoretical biases in the host potential. The feasibility of using the Minimum Entropy Method to test a wide range of gravity theories is illustrated by evolving restricted N-body models in a Newtonian potential and examining the changes in entropy introduced by Dirac, MONDian, and f(R) gravity modifications.

  18. Cold-Start Emissions Control in Hybrid Vehicles Equipped with a Passive Hydrocarbon and NOx Adsorber

    SciTech Connect (OSTI)

    Gao, Zhiming; Kim, Miyoung; Choi, Jae-Soon; Daw, C Stuart; Parks, II, James E; Smith, David E

    2012-01-01

    We presents a study of the potential for using low-cost sorbent materials (i.e. Ag-Beta-zeolite and Fe-Mn-Zr transition metal oxides) to temporally trap hydrocarbons (HCs) and nitrogen oxides (NOx) emissions during cold-start periods in HEVs and PHEVs over transient driving cycles. The adsorption behavior of the candidate sorbent materials was characterized in our laboratory flow reactor experiments. The parameters were then used to develop a one-dimensional, transient device model which has been implemented in the Powertrain Systems Analysis Toolkit (PSAT) to simulate a passive HC and NOx absorber device. The results show that such an absorber can substantially reduce HC and NOx emissions by storing them when the 3-way catalyst is too cool to function and re-releasing them when the exhaust temperature rises. These improved emission controls do not involve any penalty in fuel consumption or require any change in engine operation. The cost of these sorbent materials is also much less than conventional 3-way catalysts.

  19. A coupled theory of tropical climatology: Warm pool, cold tongue, and Walker circulation

    SciTech Connect (OSTI)

    Zhengyu Liu; Boyin Huang

    1997-07-01

    Based on results from analytic and general circulation models, the authors propose a theory for the coupled warm pool, cold tongue, and Walker circulation system. The intensity of the coupled system is determined by the coupling strength, the local equilibrium time, and latitudinal differential heating. Most importantly, this intensity is strongly regulated in the coupled system, with a saturation level that can be reached at a modest coupling strength. The saturation west-east sea surface temperature difference (and the associated Walker circulation) corresponds to about one-quarter of the latitudinal differential equilibrium temperature. This regulation is caused primarily by the decoupling of the SST gradient from a strong ocean current. The author`s estimate suggests that the present Pacific is near the saturation state. Furthermore, the much weaker Walker circulation system in the Atlantic Ocean is interpreted as being the result of the influence of the adjacent land, which is able to extend into the entire Atlantic to change the zonal distribution of the trade wind. The theory is also applied to understand the tropical climatology in coupled GCM simulations, in the Last Glacial Maximum climate, and in the global warming climate, as well as in the regulation of the tropical sea surface temperature. 41 refs., 15 figs.

  20. Bohm criterion in a dusty plasma with nonextensive electrons and cold ions

    SciTech Connect (OSTI)

    Liu, Y.; Zhou, L.; Liu, S. Q.

    2013-04-15

    The Bohm criterion in a dusty plasma containing nonextensively distributed electrons and cold ions is investigated within the framework of probe model including the effects of dust charge fluctuation. It is shown that the critical Mach number upshifts with the decrease of electron nonextensive parameter (q{sub e}) and the increase of the ion-to-electron number density ratio (R{sub n}) when the effects of dust charge fluctuation are out of consideration. Once the effects of dust charge fluctuation are included, with the increase of R{sub n}, the critical Mach number increases first, then decreases. The slop of the critical Mach number curves in the region R{sub n} Much-Greater-Than 1 for q{sub e}>1 becomes more gradual than that for q{sub e}<1. When critical Mach number is defined with respect to modified ion acoustic wave speed, it should be larger than unity in the case free of dust charge fluctuation. Whereas when R{sub n} Much-Greater-Than 1, it may be smaller than unity due to the effect of dust charge fluctuation.

  1. The Production of Advanced Glass Ceramic HLW Forms using Cold Crucible Induction Melter

    SciTech Connect (OSTI)

    Veronica J Rutledge; Vince Maio

    2013-10-01

    Cold Crucible Induction Melters (CCIMs) will favorably change how High-Level radioactive Waste (from nuclear fuel recovery) is treated in the 21st century. Unlike the existing Joule-Heated Melters (JHMs) currently in operation for the glass-based immobilization of High-Level Waste (HLW), CCIMs offer unique material features that will increase melt temperatures, increase throughput, increase mixing, increase loading in the waste form, lower melter foot prints, eliminate melter corrosion and lower costs. These features not only enhance the technology for producing HLW forms, but also provide advantageous attributes to the waste form by allowing more durable alternatives to glass. This paper discusses advantageous features of the CCIM, with emphasis on features that overcome the historical issues with the JHMs presently utilized, as well as the benefits of glass ceramic waste forms over borosilicate glass waste forms. These advantages are then validated based on recent INL testing to demonstrate a first-of-a-kind formulation of a non-radioactive ceramic-based waste form utilizing a CCIM.

  2. The genome of the polar eukaryotic microalga Coccomyxa subellipsoidea reveals traits of cold adaptation

    SciTech Connect (OSTI)

    Blanc, Guillaume; Agarkova, Irina; Grimwood, Jane; Kuo, Alan; Brueggeman, Andrew; Dunigan, David D.; Gurnon, James; Ladunga, Istvan; Lindquist, Erika; Lucas, Susan; Pangilinan, Jasmyn; Proschold, Thomas; Salamov, Asaf; Schmutz, Jeremy; Weeks, Donald; Tamada, Takashi; Lomsadze, Alexandre; Borodovsky, Mark; Claverie, Jean-Michel; Grigoriev, Igor V.; Van Etten, James L.

    2012-02-13

    Background Little is known about the mechanisms of adaptation of life to the extreme environmental conditions encountered in polar regions. Here we present the genome sequence of a unicellular green alga from the division chlorophyta, Coccomyxa subellipsoidea C-169, which we will hereafter refer to as C-169. This is the first eukaryotic microorganism from a polar environment to have its genome sequenced. Results The 48.8 Mb genome contained in 20 chromosomes exhibits significant synteny conservation with the chromosomes of its relatives Chlorella variabilis and Chlamydomonas reinhardtii. The order of the genes is highly reshuffled within synteny blocks, suggesting that intra-chromosomal rearrangements were more prevalent than inter-chromosomal rearrangements. Remarkably, Zepp retrotransposons occur in clusters of nested elements with strictly one cluster per chromosome probably residing at the centromere. Several protein families overrepresented in C. subellipsoidae include proteins involved in lipid metabolism, transporters, cellulose synthases and short alcohol dehydrogenases. Conversely, C-169 lacks proteins that exist in all other sequenced chlorophytes, including components of the glycosyl phosphatidyl inositol anchoring system, pyruvate phosphate dikinase and the photosystem 1 reaction center subunit N (PsaN). Conclusions We suggest that some of these gene losses and gains could have contributed to adaptation to low temperatures. Comparison of these genomic features with the adaptive strategies of psychrophilic microbes suggests that prokaryotes and eukaryotes followed comparable evolutionary routes to adapt to cold environments.

  3. Performance House: A Cold Climate Challenge Home, Old Greenwich, Connecticut (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2013-11-01

    By working with builder partners on test homes, researchers from the U.S. Department of Energy's Building America program can vet whole-house building strategies and avoid potential unintended consequences of implementing untested solution packages on a production scale. To support this research, Building America team Consortium for Advanced Residential Buildings (CARB) partnered with Preferred Builders Inc. on a high-performance test home in Old Greenwich, Connecticut. The philosophy and science behind the 2,700 ft2 "Performance House" was based on the premise that homes should be safe, healthy, comfortable, durable, efficient, and adaptable to the needs of homeowners. The technologies and strategies used in the "Performance House" were best practices rather than cutting edge, with a focus on simplicity in construction, maintenance, and operation. Achieving 30% source energy savings compared with a home built to the 2009 International Energy Conservation Code in the cold climate zone requires that nearly all components and systems be optimized. Careful planning and design are critical. The end result was a DOE Challenge Home that achieved a Home Energy Rating System (HERS) Index Score of 20 (43 without photovoltaics [PV]).

  4. Cold black holes in the Harlow–Hayden approach to firewalls

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Ong, Yen Chin; McInnes, Brett; Chen, Pisin

    2014-12-31

    Firewalls are controversial principally because they seem to imply departures from general relativistic expectations in regions of spacetime where the curvature need not be particularly large. One of the virtues of the Harlow–Hayden approach to the firewall paradox, concerning the time available for decoding of Hawking radiation emanating from charged AdS black holes, is precisely that it operates in the context of cold black holes, which are not strongly curved outside the event horizon. Here we clarify this point. The approach is based on ideas borrowed from applications of the AdS/CFT correspondence to the quark–gluon plasma. Firewalls aside, our workmore » presents a detailed analysis of the thermodynamics and evolution of evaporating charged AdS black holes with flat event horizons. We show that, in one way or another, these black holes are always eventually destroyed in a time which, while long by normal standards, is short relative to the decoding time of Hawking radiation.« less

  5. Elementary framework for cold field emission from quantum-confined, non-planar emitters

    SciTech Connect (OSTI)

    Patterson, A. A. Akinwande, A. I.

    2015-05-07

    For suitably small field emitters, the effects of quantum confinement at the emitter tip may have a significant impact on the emitter performance and total emitted current density (ECD). Since the geometry of a quantum system uniquely determines the magnitude and distribution of its energy levels, a framework for deriving ECD equations from cold field electron emitters of arbitrary geometry and dimensionality is developed. In the interest of obtaining semi-analytical ECD equations, the framework is recast in terms of plane wave solutions to the Schrdinger equation via the use of the Jeffreys-Wentzel-Kramers-Brillouin approximation. To demonstrate the framework's consistency with our previous work and its capabilities in treating emitters with non-planar geometries, ECD equations were derived for the normally unconfined cylindrical nanowire (CNW) and normally confined (NC) CNW emitter geometries. As a function of the emitter radius, the NC CNW emitter ECD profile displayed a strong dependence on the Fermi energy and had an average ECD that exceeded the Fowler-Nordheim equation for typical values of the Fermi energy due to closely spaced, singly degenerate energy levels (excluding electron spin), comparatively large electron supply values, and the lack of a transverse, zero-point energy. Such characteristics suggest that emitters with non-planar geometries may be ideal for emission from both an electron supply and electrostatics perspective.

  6. Secondary production of benthic insects in three cold-desert streams

    SciTech Connect (OSTI)

    Gaines, W.L.

    1987-07-01

    Aquatic insect production was studied in three cold-desert streams in eastern Washington (Douglas Creek, Snively Springs, and Rattlesnake Springs). The size-frequency method was applied to individual taxa to estimate total insect production. production was also assessed for functional groups and trophic levels in each stream. Optioservus sp. (riffle beetles) and Baetis sp. (mayflies) accounted for 72% of the total insect numbers and 50% of the total biomass in Douglas Creek. Baetis sp. accounted for 42% of the total insect numbers and 25% of the total biomass in Snively Springs. Simulium sp. (blackflies) and Baetis sp. comprised 74% of the total insect numbers and 55% of the total biomass in Rattlesnake Springs. Grazer-scrapers (49%) and collectors (48%) were the most abundant functional groups in Douglas Creek. Collectors were the most abundant functional group in Snively Springs and Rattlesnake Springs. Herbivores and detritivores were the most abundant trophic level in Snively Springs and Rattlesnake Springs. Dipterans (midges and blackflies) were the most productive taxa within the study streams, accounting for 40% to 70% of the total community production. Production by collectors and detritivores was the highest of all functional groups and trophic levels in all study streams.

  7. AROUND THE RING WE GO: THE COLD, DENSE RING OF MOLECULAR GAS IN NGC1614

    SciTech Connect (OSTI)

    Sliwa, Kazimierz; Wilson, Christine D. [Department of Physics and Astronomy, McMaster University, Hamilton, ON L8S 4M1 (Canada); Iono, Daisuke [National Astronomical Observatory of Japan, 2-21-1, Osawa, Mitaka, Tokyo 181-8588 (Japan); Peck, Alison [National Radio Astronomy Observatory, Charlottesville, VA 22903 (United States); Matsushita, Satoki, E-mail: sliwak@mcmaster.ca, E-mail: wilson@physics.mcmaster.ca, E-mail: d.iono@nao.ac.jp, E-mail: apeck@alma.cl, E-mail: satoki@asiaa.sinica.edu.tw [Academia Sinica Institute of Astronomy and Astrophysics, PO Box 23-141, Taipei 10617, Taiwan (China)

    2014-11-20

    We present high-resolution archival Atacama Large Millimeter/submillimeter Array (ALMA) {sup 12}CO J= 3-2 and J= 6-5 and HCO{sup +} J= 4-3 observations and new CARMA {sup 12}CO and {sup 13}CO J= 1-0 observations of the luminous infrared galaxy NGC1614. The high-resolution maps show the previously identified ring-like structure while the {sup 12}CO J= 3-2 map shows extended emission that traces the extended dusty features. We combined these new observations with previously published Submillimeter Array {sup 12}CO and {sup 13}CO J= 2-1 observations to constrain the physical conditions of the molecular gas at a resolution of 230pc using a radiative transfer code and a Bayesian likelihood analysis. At several positions around the central ring-like structure, the molecular gas is cold (20-40K) and dense (>10{sup 3.0}cm{sup 3}). The only region that shows evidence of a second molecular gas component is the ''hole'' in the ring. The {sup 12}CO-to-{sup 13}CO abundance ratio is found to be greater than 130, more than twice the local interstellar medium value. We also measure the CO-to-H{sub 2} conversion factor, ?{sub CO}, to range from 0.9 to 1.5 M {sub ?} (Kkms{sup 1}pc{sup 2}){sup 1}.

  8. Retrofitting a 1960s Split-Level, Cold-Climate Home

    SciTech Connect (OSTI)

    Puttagunta, Srikanth

    2015-07-01

    National programs such as Home Performance with ENERGY STAR® and numerous other utility air sealing programs have brought awareness to homeowners of the benefits of energy efficiency retrofits. Yet, these programs tend to focus on the low-hanging fruit: air-sealing the thermal envelope and ductwork where accessible, switch to efficient lighting, and low-flow fixtures. At the other end of the spectrum, deep-energy retrofit programs are also being encouraged by various utilities across the country. While deep energy retrofits typically seek 50% energy savings, they are often quite costly and most applicable to gut-rehab projects. A significant potential for lowering energy usage in existing homes lies between the low hanging fruit and deep energy retrofit approaches - retrofits that save approximately 30% in energy over the existing conditions. A key is to be non-intrusive with the efficiency measures so the retrofit projects can be accomplished in occupied homes. This cold climate retrofit project involved the design and optimization of a home in Connecticut that sought to improve energy savings by at least 30% (excluding solar PV) over the existing home's performance. This report documents the successful implementation of a cost-effective solution package that achieved performance greater than 30% over the pre-retrofit - what worked, what did not, and what improvements could be made.

  9. Cold Climate Foundation Retrofit Experimental Hygrothermal Performance: Cloquet Residential Research Facility Laboratory Results

    SciTech Connect (OSTI)

    Goldberg, Louise F.; Harmon, Anna C.

    2015-04-01

    Thermal and moisture problems in existing basements create a unique challenge because the exterior face of the wall is not easily or inexpensively accessible. This approach addresses thermal and moisture management from the interior face of the wall without disturbing the exterior soil and landscaping. the interior and exterior environments. This approach has the potential for improving durability, comfort, and indoor air quality. This project was funded jointly by the National Renewable Energy Laboratory (NREL) and Oak Ridge National Laboratory (ORNL). ORNL focused on developing a full basement wall system experimental database to enable others to validate hygrothermal simulation codes. NREL focused on testing the moisture durability of practical basement wall interior insulation retrofit solutions for cold climates. The project has produced a physically credible and reliable long-term hygrothermal performance database for retrofit foundation wall insulation systems in zone 6 and 7 climates that are fully compliant with the performance criteria in the 2009 Minnesota Energy Code. The experimental data were configured into a standard format that can be published online and that is compatible with standard commercially available spreadsheet and database software.

  10. Effect of cold deformation on the recrystallization behavior of FePd alloy at the ordering temperature using electron backscatter diffraction

    SciTech Connect (OSTI)

    Lin, Hung-Pin; Chen, Yen-Chun; Chen, Delphic; Kuo, Jui-Chao

    2014-08-15

    In this study, the evolution of the recrystallization texture and microstructure was investigated after annealing of 50% and 90% cold-rolled FePd alloy at 530 C. The FePd alloy was produced by vacuum arc melting in an atmosphere of 97% Ar and 3% H{sub 2}. The specimens were cold rolled to achieve 50% and 90% reduction in thickness. Electron backscatter diffraction measurements were performed on the rolling directionnormal direction section. With increased deformation from 50% to 90%, recrystallized texture transition occurs. For the 50% cold-rolled alloy, the preferred orientation is (0 1 0) [11 0 1], which is close to the cubic orientation after 400 h of annealing. For the 90% cold-rolled alloy, the orientation changes to (0 5 4) [224 5] after 16 h of annealing. - Highlights: Texture and microstructure in cold-rolled FePd alloy was investigated during annealing using EBSD. The recrystallized texture of 50% cold-rolled FePd is (0 1 0) [11 0 1] at 530 C for 400 hours. The recrystallized texture of 90% cold-rolled FePd is changed to (0 5 4) [224 5] at 530 C after 16 hours.

  11. Kinetics of Cold-Cap Reactions for Vitrification of Nuclear Waste Glass Based on Simultaneous Differential Scanning Calorimetry - Thermogravimetry (DSC-TGA) and Evolved Gas Analysis (EGA)

    SciTech Connect (OSTI)

    Rodriguez, Carmen P.; Pierce, David A.; Schweiger, Michael J.; Kruger, Albert A.; Chun, Jaehun; Hrma, Pavel R.

    2013-12-03

    For vitrifying nuclear waste glass, the feed, a mixture of waste with glass-forming and modifying additives, is charged onto the cold cap that covers 90-100% of the melt surface. The cold cap consists of a layer of reacting molten glass floating on the surface of the melt in an all-electric, continuous glass melter. As the feed moves through the cold cap, it undergoes chemical reactions and phase transitions through which it is converted to molten glass that moves from the cold cap into the melt pool. The process involves a series of reactions that generate multiple gases and subsequent mass loss and foaming significantly influence the mass and heat transfers. The rate of glass melting, which is greatly influenced by mass and heat transfers, affects the vitrification process and the efficiency of the immobilization of nuclear waste. We studied the cold-cap reactions of a representative waste glass feed using both the simultaneous differential scanning calorimetry thermogravimetry (DSC-TGA) and the thermogravimetry coupled with gas chromatography-mass spectrometer (TGA-GC-MS) as complementary tools to perform evolved gas analysis (EGA). Analyses from DSC-TGA and EGA on the cold-cap reactions provide a key element for the development of an advanced cold-cap model. It also helps to formulate melter feeds for higher production rate.

  12. The effect of voltage waveform and tube diameter on transporting cold plasma strings through a flexible dielectric tube

    SciTech Connect (OSTI)

    Sohbatzadeh, Farshad; Omran, Azadeh Valinataj

    2014-11-15

    In this work, we developed transporting atmospheric pressure cold plasma using single electrode configuration through a sub-millimetre flexible dielectric tube beyond 100?cm. It was shown that the waveform of the applied high voltage is essential for controlling upstream and downstream plasma inside the tube. In this regard, sawtooth waveform enabled the transport of plasma with less applied high voltage compared to sinusoidal and pulsed form voltages. A cold plasma string as long as 130?cm was obtained by only 4?kV peak-to-peak sawtooth high voltage waveform. Optical emission spectroscopy revealed that reactive chemical species, such as atomic oxygen and hydroxyl, are generated at the tube exit. The effect of tube diameter on the transported plasma was also examined: the smaller the diameter, the higher the applied voltage. The device is likely to be used for sterilization, decontamination, and therapeutic endoscopy as already suggested by other groups in recent past years.

  13. Deuterated palladium at temperatures from 4. 3 to 400 K and pressures to 105 kbar: Search for cold fusion

    SciTech Connect (OSTI)

    Silvera, I.F.; Moshary, F. )

    1990-11-15

    We have studied a sample of deuterated palladium at pressures up to 105 kbar and temperatures from 4.3 to 400 K in an effort to detect cold fusion. A (D)/(Pd) concentration of 1.34{plus minus}0.1 was achieved. No evidence of cold fusion was found with a limit of 2.5{times}10{sup {minus}18} fusions (DD pair){sup {minus}1} s{sup {minus}1} from neutron detection and 1.5{times}10{sup {minus}8} fusions (DD pair){sup {minus}1} s{sup {minus}1} from detection of possible heating; a {gamma}-ray detector showed no evidence of {gamma} rays differing from background.

  14. Instantaneous radioiodination of rose bengal at room temperature and a cold-kit therefor. [DOE patent application

    DOE Patents [OSTI]

    O'Brien, H. Jr.; Hupf, H.B.; Wanek, P.M.

    The disclosure relates to the radioiodination of rose bengal at room temperature and a cold-kit therefor. A purified rose bengal tablet is stirred into acidified ethanol at or near room temperature, until a suspension forms. Reductant-free /sup 125/I/sup -/ is added and the resulting mixture stands until the exchange label reaction occurs at room temperature. A solution of sterile isotonic phosphate buffer and sodium hydroxide is added and the final resulting mixture is sterilized by filtration.

  15. PR_NA-03-13_FromColdWartoWaronCancer-PETRussia_10-03_.doc

    National Nuclear Security Administration (NNSA)

    U.S. Department of Energy For Immediate Release Bryan Wilkes October 28, 2003 202-586-7371 From the Cold War to the War on Cancer NNSA-sponsored program to employ Russian scientists in cancer treatment facility WASHINGTON, D.C. - Former nuclear weapons scientists, engineers and technicians will soon begin working in a Russian life-saving cancer treatment facility under an important nonproliferation program run by the National Nuclear Security Administration (NNSA). The Positron Emission

  16. The use Na, Li, K cations for modification of ZSM-5 zewolite to control hydrocarbon cold-start emission

    SciTech Connect (OSTI)

    Golubeva V.; Rohatgi U.; Korableva, A.; Anischenko, O.; Kustov, L.; Nissenbaum, V; Viola, M.B.

    2012-08-29

    This paper addresses the problem of controlling hydrocarbon emissions from cold-start of engines by investigating the adsorbents which could adsorb the hydrocarbons at cold temperatures and hold them to 250-300 ?. The materials, that has been studied, are based on the modification of ZSM-5 (SiO{sub 2}/Al{sub 2}O{sub 3} = 35) zeolite with Li, K, Na cations. It has been shown that the introduction of Li, Na and K in an amount that is equivalent to the content of Al in zeolite results in occurrence of toluene temperature desorption peaks at high-temperatures. The toluene temperature desorption curves for 5%Li-ZSM-5 and 2.3%Na-ZSM-5 zeolites are identical and have peak toluene desorption rate between 200 to 400 ?. Upon analysis of toluene adsorption isotherms for 2.3%Na-ZSM-5 and 5%Li-ZSM-5, it was concluded that the toluene diffusion inside of the modified zeolites channels is extremely slow and the sorption capacity of 2.3%Na-ZSM-5 is higher than with 5%Li-ZSM-5. The 2.3%Na-ZSM-5 didn't change toluene temperature programmed desorption (TPD) rate of curve after the treatment in environment with 10% ?{sub 2}? at 750-800 ? for about 28 h. The 2.3%Na-ZSM-5 zeolite is very promising as adsorbent to control the cold-start hydrocarbon emissions.

  17. Energy security in the post-Cold War era: Identifying future courses for crises

    SciTech Connect (OSTI)

    Freund, M.T.; Wise, J.A.; Ulibarri, C.A.; Shaw, B.R.; Seely, H.E.; Roop, J.M.

    1994-11-01

    This paper addresses US energy security in the post-Cold War era for a conference on energy security jointly sponsored by the Department of Energy and the National Defense University. It examines the evolving nature of energy security based on analysis of past crisis-inducing events and-discusses potentially important geopolitical, environmental, regulatory, and economic developments during the next twenty-five years. The paper steps beyond the traditional economic focus of energy security issues to examine the interplay between fundamental economic and technical drivers on the one hand, and political, environmental, and perceptual phenomena, on the other hand, that can combine to create crises where none were expected. The paper expands on the premise that the recent demise of the Soviet Union and other changing world conditions have created a new set of energy dynamics, and that it is imperative that the United States revise its energy security perspective accordingly. It proceeds by reviewing key factors that comprise the concepts of ``energy security`` and ``energy crisis`` and how they may fit into the new world energy security equation. The study also presents a series of crisis scenarios that could develop during the next twenty-five years, paying particular attention to mechanisms and linked crisis causes and responses. It concludes with a discussion of factors that may serve to warn analysts and decision makers of impending future crises conditions. The crisis scenarios contained in this report should be viewed only as a representative sample of the types of situations that could occur. They serve to illustrate the variety of factors that can coalesce to produce a ``crisis.``

  18. A submillimeter galaxy illuminating its circumgalactic medium: Ly? scattering in a cold, clumpy outflow

    SciTech Connect (OSTI)

    Geach, J. E.; Coppin, K. E. K.; Smith, D. J. B.; Bower, R. G.; Alexander, D. M.; Swinbank, A. M.; Blain, A. W.; Bremer, M. N.; Chapin, E. L.; Chapman, S. C.; Clements, D. L.; Dunlop, J. S.; Koprowski, M. P.; Micha?owski, M. J.; Farrah, D.; Jenness, T.; Robson, E. I.; Scott, D.; Spaans, M.; Van der Werf, P.

    2014-09-20

    We report the detection at 850 ?m of the central source in SSA22-LAB1, the archetypal 'Lyman-? Blob' (LAB), a 100 kpc scale radio-quiet emission-line nebula at z = 3.1. The flux density of the source, S {sub 850} = 4.6 1.1 mJy, implies the presence of a galaxy or group of galaxies with a total luminosity of L {sub IR} ? 10{sup 12} L {sub ?}. The position of an active source at the center of a ?50 kpc radius ring of linearly polarized Ly? emission detected by Hayes et al. suggests that the central source is leaking Ly? photons preferentially in the plane of the sky, which undergo scattering in H I clouds at a large galactocentric radius. The Ly? morphology around the submillimeter detection is reminiscent of a biconical outflow, and the average Ly? line profiles of the two 'lobes' are dominated by a red peak, which is expected for a resonant line emerging from a medium with a bulk velocity gradient that is outflowing relative to the line center. Taken together, these observations provide compelling evidence that the central active galaxy (or galaxies) is responsible for a large fraction of the extended Ly? emission and morphology. Less clear is the history of the cold gas in the circumgalactic medium being traced by Ly?: is it mainly pristine material accreting into the halo that has not yet been processed through an interstellar medium (ISM), now being blown back as it encounters an outflow, or does it mainly comprise gas that has been swept-up within the ISM and expelled from the galaxy?.

  19. SLUDGE TREATMENT PROJECT KOP DISPOSITION - THERMAL AND GAS ANALYSIS FOR THE COLD VACUUM DRYING FACILITY

    SciTech Connect (OSTI)

    SWENSON JA; CROWE RD; APTHORPE R; PLYS MG

    2010-03-09

    The purpose of this document is to present conceptual design phase thermal process calculations that support the process design and process safety basis for the cold vacuum drying of K Basin KOP material. This document is intended to demonstrate that the conceptual approach: (1) Represents a workable process design that is suitable for development in preliminary design; and (2) Will support formal safety documentation to be prepared during the definitive design phase to establish an acceptable safety basis. The Sludge Treatment Project (STP) is responsible for the disposition of Knock Out Pot (KOP) sludge within the 105-K West (KW) Basin. KOP sludge consists of size segregated material (primarily canister particulate) from the fuel and scrap cleaning process used in the Spent Nuclear Fuel process at K Basin. The KOP sludge will be pre-treated to remove fines and some of the constituents containing chemically bound water, after which it is referred to as KOP material. The KOP material will then be loaded into a Multi-Canister Overpack (MCO), dried at the Cold Vacuum Drying Facility (CVDF) and stored in the Canister Storage Building (CSB). This process is patterned after the successful drying of 2100 metric tons of spent fuel, and uses the same facilities and much of the same equipment that was used for drying fuel and scrap. Table ES-l present similarities and differences between KOP material and fuel and between MCOs loaded with these materials. The potential content of bound water bearing constituents limits the mass ofKOP material in an MCO load to a fraction of that in an MCO containing fuel and scrap; however, the small particle size of the KOP material causes the surface area to be significantly higher. This relatively large reactive surface area represents an input to the KOP thermal calculations that is significantly different from the calculations for fuel MCOs. The conceptual design provides for a copper insert block that limits the volume available to receive KOP material, enhances heat conduction, and functions as a heat source and sink during drying operations. This use of the copper insert represents a significant change to the thermal model compared to that used for the fuel calculations. A number of cases were run representing a spectrum of normal and upset conditions for the drying process. Dozens of cases have been run on cold vacuum drying of fuel MCOs. Analysis of these previous calculations identified four cases that provide a solid basis for judgments on the behavior of MCO in drying operations. These four cases are: (1) Normal Process; (2) Degraded vacuum pumping; (3) Open MCO with loss of annulus water; and (4) Cool down after vacuum drying. The four cases were run for two sets of input parameters for KOP MCOs: (1) a set of parameters drawn from safety basis values from the technical data book and (2) a sensitivity set using parameters selected to evaluate the impact of lower void volume and smaller particle size on MCO behavior. Results of the calculations for the drying phase cases are shown in Table ES-2. Cases using data book safety basis values showed dry out in 9.7 hours and heat rejection sufficient to hold temperature rise to less than 25 C. Sensitivity cases which included unrealistically small particle sizes and corresponding high reactive surface area showed higher temperature increases that were limited by water consumption. In this document and in the attachment (Apthorpe, R. and M.G. Plys, 2010) cases using Technical Databook safety basis values are referred to as nominal cases. In future calculations such cases will be called safety basis cases. Also in these documents cases using parameters that are less favorable to acceptable performance than databook safety values are referred to as safety cases. In future calculations such cases will be called sensitivity cases or sensitivity evaluations Calculations to be performed in support of the detailed design and formal safety basis documentation will expand the calculations presented in this document to include: additional features of the drying cycle, more realistic treatment of uranium metal consumption during oxidation, larger water inventory, longer time scales, and graphing of results of hydrogen gas concentration.

  20. Affordable Cold Climate Infill Housing with Hybrid Insulation Approach, Wyandotte, Michigan (Fact Sheet), Building America Case Study: Whole-House Solutions for New Homes, Building Technologies Office (BTO)

    Energy Savers [EERE]

    Affordable Cold Climate Infill Housing with Hybrid Insulation Approach Wyandotte, Michigan PROJECT INFORMATION Construction: New home Type: Single-family, affordable Builder: City of Wyandotte with various local homebuilders www.wyandotte.net Size: 1,150 to 1,500 ft 2 Price Range: $113,000-$138,000 Date completed: 2012 Climate Zone: Cold PERFORMANCE DATA HERS index: * 2009 IECC = 102 * Case study house 1,475 ft 2 * With renewables = NA * Without renewables = 75 Projected annual energy cost

  1. Extended Development Work to Validate a HLW Calcine Waste Form via INL's Cold Crucible Induction Melter

    SciTech Connect (OSTI)

    James A. King; Vince Maio

    2011-09-01

    To accomplish calcine treatment objectives, the Idaho Clean-up Project contractor, CWI, has chosen to immobilize the calcine in a glass-ceramic via the use of a Hot-Isostatic-Press (HIP); a treatment selection formally documented in a 2010 Record of Decision (ROD). Even though the HIP process may prove suitable for the calcine as specified in the ROD and validated in a number of past value engineering sessions, DOE is evaluating back-up treatment methods for the calcine as a result of the technical, schedule, and cost risk associated with the HIPing process. Consequently DOE HQ has requested DOE ID to make INL's bench-scale cold-crucible induction melter (CCIM) available for investigating its viability as a process alternate to calcine treatment. The waste form is the key component of immobilization of radioactive waste. Providing a solid, stable, and durable material that can be easily be stored is the rationale for immobilization of radioactive waste material in glass, ceramic, or glass-ceramics. Ceramic waste forms offer an alternative to traditional borosilicate glass waste forms. Ceramics can usually accommodate higher waste loadings than borosilicate glass, leading to smaller intermediate and long-term storage facilities. Many ceramic phases are known to possess superior chemical durability as compared to borosilicate glass. However, ceramics are generally multiphase systems containing many minor phase that make characterization and prediction of performance within a repository challenging. Additionally, the technologies employed in ceramic manufacture are typically more complex and expensive. Thus, many have proposed using glass-ceramics as compromise between in the more inexpensive, easier to characterize glass waste forms and the more durable ceramic waste forms. Glass-ceramics have several advantages over traditional borosilicate glasses as a waste form. Borosilicate glasses can inadvertently devitrify, leading to a less durable product that could crack during cooling and crystals may be prone to dissolution. By designing a glass-ceramics, the risks of deleterious effects from devitrification are removed. Furthermore, glass-ceramics have higher mechanical strength and impact strengths and possess greater chemical durability as noted above. Glass-ceramics should provide a waste form with the advantages of glass - ease of manufacture - with improved mechanical properties, thermal stability, and chemical durability. This report will cover aspects relevant for the validation of the CCIM use in the production of glass-ceramic waste forms.

  2. TRASH TO TREASURE: CONVERTING COLD WAR LEGACY WASTE INTO WEAPONS AGAINST CANCER

    SciTech Connect (OSTI)

    Nicholas, R.G.; Lacy, N.H.; Butz, T.R.; Brandon, N.E.

    2004-10-06

    As part of its commitment to clean up Cold War legacy sites, the U.S. Department of Energy (DOE) has initiated an exciting and unique project to dispose of its inventory of uranium-233 (233U) stored at Oak Ridge National Laboratory (ORNL), and extract isotopes that show great promise in the treatment of deadly cancers. In addition to increasing the supply of potentially useful medical isotopes, the project will rid DOE of a nuclear concern and cut surveillance and security costs. For more than 30 years, DOE's ORNL has stored over 1,200 containers of fissile 233U, originally produced for several defense-related projects, including a pilot study that looked at using 233U as a commercial reactor fuel. This uranium, designated as special nuclear material, requires expensive security, safety, and environmental controls. It has been stored at an ORNL facility, Building 3019A, that dates back to the Manhattan Project. Down-blending the material to a safer form, rather than continuing to store it, will eliminate a $15 million a year financial liability for the DOE and increase the supply of medical isotopes by 5,700 percent. During the down-blending process, thorium-229 (229Th) will be extracted. The thorium will then be used to extract actinium-225 (225Ac), which will ultimately supply its progeny, bismuth-213 (213Bi), for on-going cancer research. The research includes Phase II clinical trials for the treatment of acute myelogenous leukemia at Sloan-Kettering Memorial Cancer Center in New York, as well as other serious cancers of the lungs, pancreas, and kidneys using a technique known as alpha-particle radioimmunotherapy. Alpha-particle radioimmunotherapy is based on the emission of alpha particles by radionuclides. 213Bi is attached to a monoclonal antibody that targets specific cells. The bismuth then delivers a high-powered but short-range radiation dose, effectively killing the cancerous cells but sparing the surrounding tissue. Production of the actinium and bismuth would be a private venture at no cost to the government. Isotek Systems, LLC, was commissioned by the DOE to execute the project, known as the 233U Disposition, Medical Isotope Production, and Building 3019 Complex Shutdown Project. Isotek is a partnership between Duratek Federal Services, Burns and Roe Enterprises, and Nuclear Fuel Services. By pooling their pioneering experiences in nuclear engineering and design, nuclear recycling, and waste management, the partnership has developed a novel process to meet this clean-up milestone. The project is not only important for its cancer treatment potential, but also for setting the stage for reducing global threats through the down-blending of materials.

  3. The Genome Sequence of the psychrophilic archaeon, Methanococcoides burtonii: the Role of Genome Evolution in Cold-adaptation

    SciTech Connect (OSTI)

    Allen, Michelle A.; Lauro, Federico M.; Williams, Timothy J.; Burg, Dominic; Siddiqui, Khawar S.; De Francisci, David; Chong, Kevin W.Y.; Pilak, Oliver; Chew, Hwee H.; De Maere, Matthew Z.; Ting, Lily; Katrib, Marilyn; Ng, Charmaine; Sowers, Kevin R.; Galperin, Michael Y.; Anderson, Iain J.; Ivanova, Natalia; Dalin, Eileen; Martinez, Michelle; Lapidus, Alla; Hauser, Loren; Land, Miriam; Thomas, Torsten; Cavicchioli, Ricardo

    2009-04-01

    Psychrophilic archaea are abundant and perform critical roles throughout the Earth's expansive cold biosphere. Here we report the first complete genome sequence for a psychrophilic methanogenic archaeon, Methanococcoides burtonii. The genome sequence was manually annotated including the use of a five tiered Evidence Rating system that ranked annotations from Evidence Rating (ER) 1 (gene product experimentally characterized from the parent organism) to ER5 (hypothetical gene product) to provide a rapid means of assessing the certainty of gene function predictions. The genome is characterized by a higher level of aberrant sequence composition (51%) than any other archaeon. In comparison to hyper/thermophilic archaea which are subject to selection of synonymous codon usage, M. burtonii has evolved cold adaptation through a genomic capacity to accommodate highly skewed amino acid content, while retaining codon usage in common with its mesophilic Methanosarcina cousins. Polysaccharide biosynthesis genes comprise at least 3.3% of protein coding genes in the genome, and Cell wall/membrane/envelope biogenesis COG genes are over-represented. Likewise, signal transduction (COG category T) genes are over-represented and M. burtonii has a high 'IQ' (a measure of adaptive potential) compared to many methanogens. Numerous genes in these two over-represented COG categories appear to have been acquired from {var_epsilon}- and {delta}-proteobacteria, as do specific genes involved in central metabolism such as a novel B form of aconitase. Transposases also distinguish M. burtonii from other archaea, and their genomic characteristics indicate they play an important role in evolving the M. burtonii genome. Our study reveals a capacity for this model psychrophile to evolve through genome plasticity (including nucleotide skew, horizontal gene transfer and transposase activity) that enables adaptation to the cold, and to the biological and physical changes that have occurred over the last several thousand years as it adapted from a marine, to an Antarctic lake environment.

  4. Application of evolved gas analysis to cold-cap reactions of melter feeds for nuclear waste vitrification

    Office of Scientific and Technical Information (OSTI)

    Thermochimica Acta 592 (2014) 86-92 Contents lists available at ScienceDirect Thermochimica Acta journal homepage www.elsevier.com/locate/tca Application of evolved gas analysis to cold-cap reactions of melter feeds for nuclear waste vitrification Carmen P. Rodrigueza, Jaehun Chun3'*, Michael J. Schweigera, Albert A. Krugerb, Pavel Hrma a,c a Pacific Northwest National Laboratory, 902 Battelle Blvd., P.O. Box 999, MSIN K6-24, Richland,WA 99352, USA b U.S. Department of Energy Office of River

  5. Single-Bunch Electron Cloud Effects in the GLC/NLC, US-Cold and TESLA Low Emittance Transport Lines

    SciTech Connect (OSTI)

    Bates, D.

    2005-04-12

    This paper examines the severity of the electron cloud effects in the Low Emittance Transport (LET) of linear colliders including the Bunch-Compressor System (BCS) and Beam Delivery System (BDS). We examine the electron cloud effects in the normal-conducting GLC/NLC or X-Band, and the super-conducting US-Cold and TESLA linear collider designs through the use of specially developed computer simulation codes. An estimate of the critical cloud density is given for the BDS and BCS of the X-Band collider.

  6. p{sub x}+ip{sub y} Superfluid from s-Wave Interactions of Fermionic Cold Atoms

    SciTech Connect (OSTI)

    Zhang Chuanwei; Tewari, Sumanta; Lutchyn, Roman M.; Das Sarma, S.

    2008-10-17

    Two-dimensional (p{sub x}+ip{sub y}) superfluids or superconductors offer a playground for studying intriguing physics such as quantum teleportation, non-Abelian statistics, and topological quantum computation. Creating such a superfluid in cold fermionic atom optical traps using p-wave Feshbach resonance is turning out to be challenging. Here we propose a method to create a p{sub x}+ip{sub y} superfluid directly from an s-wave interaction making use of a topological Berry phase, which can be artificially generated. We discuss ways to detect the spontaneous Hall mass current, which acts as a diagnostic for the chiral p-wave superfluid.

  7. Building America Case Study: Field Performance of Inverter-Driven Heat Pumps in Cold Climates - Connecticut, Massachusetts, and Vermont

    SciTech Connect (OSTI)

    2015-09-01

    New inverter-driven ASHPs are gaining ground in colder climates. These systems operate at sub-zero temperatures without the use of electric resistance backup. There are still uncertainties, however, about cold-climate capacity and efficiency in cold weather and questions such as measuring: power consumption, supply, return, and outdoor air temperatures, and air flow through the indoor fan coil. CARB observed a wide range of operating efficiencies and outputs from site to site. Maximum capacities were found to be generally in line with manufacturer's claims as outdoor temperatures fell to -10 degrees F. The reasons for the wide range in heating performance likely include: low indoor air flow rates, poor placement of outdoor units, relatively high return air temperatures, thermostat set back, integration with existing heating systems, and occupants limiting indoor fan speed. Even with lower efficiencies than published in other studies, most of the heat pumps here still provide heat at lower cost than oil, propane, or certainly electric resistance systems.

  8. Assessing Foundation Insulation Strategies for the 2012 International Energy Conservation Code in Cold Climate New Home Construction

    SciTech Connect (OSTI)

    VonThoma, E.; Ojczyk, C.; Mosiman, G.

    2013-04-01

    While the International Energy Conservation Code 2012 (IECC 2012) has been adopted at a national level, only two cold climate states have adopted it as their new home energy code. Understanding the resistance to adoption is important in assisting more states accept the code and engage deep energy strategies nationwide. This three-part assessment by the NorthernSTAR Building America Partnership was focused on foundation insulation R-values for cold climates and the design, construction, and performance implications. In Part 1 a literature review and attendance at stakeholder meetings held in Minnesota were used to assess general stakeholder interest and concerns regarding proposed code changes. Part 2 includes drawings of robust foundation insulation systems that were presented at one Minnesota stakeholder meeting to address critical issues and concerns for adopting best practice strategies. In Part 3 a sampling of builders participated in a telephone interview to gain baseline knowledge on insulation systems used to meet the current energy code and how the same builders propose to meet the new proposed code.

  9. Airtightness Results of Roof-Only Air Sealing Strategies on 1-1/2 Story Homes in Cold Climates

    SciTech Connect (OSTI)

    Ojczyk, C.; Murry, T.; Mosiman, G.

    2014-07-01

    In this second study on solutions to ice dams in 1-1/2 story homes, five test homes located in both cold and very cold climates were analyzed for air leakage reduction rates following modifications by independent contractors on owner-occupied homes. The reason for choosing this house type was they are very common in our area and very difficult to air seal and insulate effectively. Two projects followed a roof-only Exterior Thermal Moisture Management System (ETMMS) process. One project used an interior-only approach to roof air sealing and insulation. The remaining two projects used a deep energy retrofit approach for whole house (foundation wall, above grade wall, roof) air leakage and heat loss reduction. All were asked to provide information regarding project goals, process, and pre and post-blower door test results. Additional air leakage reduction data was provided by several NorthernSTAR Building America industry partners for interior-applied, roof-only modifications on 1-1/2 story homes. The data represents homes in the general market as well as homes that were part of the state of Minnesota weatherization program. A goal was to compare exterior air sealing methods with interior approaches. This pool of data enabled us to compare air tightness data from over 220 homes using similar air seal methods.

  10. Airtightness Results of Roof-Only Air Sealing Strategies on 1 ½-Story Homes in Cold Climates

    SciTech Connect (OSTI)

    Ojczyk, C.; Murry, T.; Mosiman, G.

    2014-07-01

    In this second study on solutions to ice dams in 1-1/2 story homes, the NorthernSTAR Building America Partnership team analyzed five test homes located in both cold and very cold climates for air leakage reduction rates following modifications by independent contractors on owner-occupied homes. These homes were chosen for testing as they are common in Minnesota and very difficult to air seal and insulate effectively. Two projects followed a roof-only Exterior Thermal Moisture Management System (ETMMS) process. One project used an interior-only approach to roof air sealing and insulation. The remaining two projects used a deep energy retrofit approach for whole house (foundation wall, above grade wall, roof) air leakage and heat loss reduction. All were asked to provide information regarding project goals, process, and pre and post-blower door test results. Additional air leakage reduction data was provided by several NorthernSTAR industry partners for interior-applied, roof-only modifications on 1-1/2 story homes. The data represents homes in the general market as well as homes that were part of the state of Minnesota weatherization program. A goal was to compare exterior air sealing methods with interior approaches. This pool of data enabled the team to compare air tightness data from over 220 homes using similar air seal methods.

  11. Tribological Testing of Anti-Adhesive coatings for Cold Rolling Mill Rolls--Application to TiN-Coated Rolls

    SciTech Connect (OSTI)

    Ould, Choumad; Montmitonnet, Pierre; Gachon, Yves; Badiche, Xavier

    2011-05-04

    Roll life is a major issue in cold strip rolling. Roll wear may result either in too low roll roughness, bringing friction below the minimum requested for strip entrainment; or it may degrade strip surface quality. On the contrary, adhesive wear and transfer (''roll coating'', ''pick up'') may form a thick metallic deposits on the roll which increases friction excessively and degrades strip surface again [1]. The roll surface, with the help of a materials-adapted lubricant, must therefore possess anti-wear and anti-adhesive properties. Thus, High Speed Steeel (HSS) rolls show superior properties compared with standard Cr-steel rolls due to their high carbide surface coverage. Another way to improve wear and adhesion properties of surfaces is to apply hard metallic (hard-Cr) or ceramic coatings. Chromium is renowned for its excellent anti-wear and anti-adhesive properties and may serve as a reference. Here, as a first step towards alternative, optimised coatings, a PVD TiN coating has been deposited on tool steels, as previous attempts have proved TiN to be rather successful in cold rolling experiments [2,3]. Different tribological tests are reported here, giving insight in both anti-adhesive properties and fatigue life improvement.

  12. 2014 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond

    SciTech Connect (OSTI)

    Lewis, Mike

    2015-02-01

    This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (LA 000161 01, Modification B), for the wastewater land application site at the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond from November 1, 2013–October 31, 2014. The report contains the following information; Facility and system description; Permit required effluent monitoring data and loading rates; Permit required groundwater monitoring data; Status of compliance activities; Noncompliance issues; and Discussion of the facility’s environmental impacts. During the 2014 permit year, approximately 238 million gallons of wastewater were discharged to the Cold Waste Pond. This is well below the maximum annual permit limit of 375 million gallons. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest near the Cold Waste Pond and decrease rapidly as the distance from the Cold Waste Pond increases. Although concentrations of sulfate and total dissolved solids are elevated near the Cold Waste Pond, both parameters are below the Ground Water Quality Rule Secondary Constituent Standards in the downgradient monitoring wells.

  13. 2010 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond

    SciTech Connect (OSTI)

    mike lewis

    2011-02-01

    This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (#LA 000161 01, Modification B), for the wastewater land application site at the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond from November 1, 2009 through October 31, 2010. The report contains the following information: • Facility and system description • Permit required effluent monitoring data and loading rates • Groundwater monitoring data • Status of compliance activities • Discussion of the facility’s environmental impacts During the 2010 permit year, approximately 164 million gallons of wastewater were discharged to the Cold Waste Pond. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest near the Cold Waste Pond and decrease rapidly as the distance from the Cold Waste Pond increases. Although concentrations of sulfate and total dissolved solids are elevated near the Cold Waste Pond, both parameters were below the Ground Water Quality Rule Secondary Constituent Standards in the down gradient monitoring wells.

  14. 2013 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond

    SciTech Connect (OSTI)

    Mike Lewis

    2014-02-01

    This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (#LA 000161 01, Modification B), for the wastewater land application site at the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond from November 1, 2012–October 31, 2013. The report contains the following information: • Facility and system description • Permit required effluent monitoring data and loading rates • Groundwater monitoring data • Status of compliance activities • Noncompliance issues • Discussion of the facility’s environmental impacts. During the 2013 permit year, approximately 238 million gallons of wastewater was discharged to the Cold Waste Pond. This is well below the maximum annual permit limit of 375 million gallons. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest near the Cold Waste Pond and decrease rapidly as the distance from the Cold Waste Pond increases. Although concentrations of sulfate and total dissolved solids are elevated near the Cold Waste Pond, both parameters are below the Ground Water Quality Rule Secondary Constituent Standards in the down gradient monitoring wells.

  15. Temperature measurement of cold atoms using single-atom transits and Monte Carlo simulation in a strongly coupled atom-cavity system

    SciTech Connect (OSTI)

    Li, Wenfang; Du, Jinjin; Wen, Ruijuan; Yang, Pengfei; Li, Gang; Zhang, Tiancai; Liang, Junjun

    2014-03-17

    We investigate the transmission of single-atom transits based on a strongly coupled cavity quantum electrodynamics system. By superposing the transit transmissions of a considerable number of atoms, we obtain the absorption spectra of the cavity induced by single atoms and obtain the temperature of the cold atom. The number of atoms passing through the microcavity for each release is also counted, and this number changes exponentially along with the atom temperature. Monte Carlo simulations agree closely with the experimental results, and the initial temperature of the cold atom is determined. Compared with the conventional time-of-flight (TOF) method, this approach avoids some uncertainties in the standard TOF and sheds new light on determining temperature of cold atoms by counting atoms individually in a confined space.

  16. G305.136+0.068: A MASSIVE AND DENSE COLD CORE IN AN EARLY STAGE OF EVOLUTION

    SciTech Connect (OSTI)

    Garay, Guido; Mardones, Diego; Contreras, Yanett; Servajean, Elise; Guzmán, Andrés E.; Pineda, Jaime E.

    2015-01-20

    We report molecular line observations, made with ASTE and SEST, and dust continuum observations at 0.87 mm, made with APEX, toward the cold dust core G305.136+0.068. The molecular observations show that the core is isolated and roughly circularly symmetric and imply that it has a mass of 1.1 × 10{sup 3} M {sub ☉}. A simultaneous model fitting of the spectra observed in four transitions of CS, using a non-LTE radiative transfer code, indicates that the core is centrally condensed, with the density decreasing with radius as r {sup –1.8}, and that the turbulent velocity increases toward the center. The dust observations also indicate that the core is highly centrally condensed and that the average column density is 1.1 g cm{sup –2}, a value slightly above the theoretical threshold required for the formation of high-mass stars. A fit to the spectral energy distribution of the emission from the core indicates a dust temperature of 17 ± 2 K, confirming that the core is cold. Spitzer images show that the core is seen in silhouette from 3.6 to 24.0 μm and that it is surrounded by an envelope of emission, presumably tracing an externally excited photo-dissociated region. We found two embedded sources within a region of 20'' centered at the peak of the core, one of which is young, has a luminosity of 66 L {sub ☉}, and is accreting mass with a high accretion rate of ∼1 × 10{sup –4} M {sub ☉} yr{sup –1}. We suggest that this object corresponds to the seed of a high-mass protostar still in the process of formation. The present observations support the hypothesis that G305.136+0.068 is a massive and dense cold core in an early stage of evolution, in which the formation of a high-mass star has just started.

  17. Prototypical Rod Consolidation Demonstration Project. Phase 3, Final report: Volume 1, Cold checkout test report, Book 1

    SciTech Connect (OSTI)

    Not Available

    1993-05-01

    The objective of Phase 3 of the Prototypical Rod consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod consolidation System as described in the NUS Phase 2 Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase 3 effort the system was tested on a component, subsystem, and system level. This volume 1, discusses the PRCDP Phase 3 Test Program that was conducted by the HALLIBURTON NUS Environmental Corporation under contract AC07-86ID12651 with the United States Department of Energy. This document, Volume 1, Book 1 discusses the following topics: the background of the project; test program description; summary of tests and test results; problem evaluation; functional requirements confirmation; recommendations; and completed test documentation for tests performed in Phase 3.

  18. Preliminary experimental study on cold fusion using deuterium gas and deuterium plasma in the presence of palladium

    SciTech Connect (OSTI)

    Gu, A.G.; Teng, R.K.F.; Miller, M.S.; Sprouse, W.J. )

    1989-09-01

    The authors describe a series of experiments using deuterium gas and deuterium plasma in the presence of palladium designed to observe the possibility of cold fusion. Two kinds of preliminary experiments were recently performed. One involved the diffusion of deuterium gas into paladium. The gas was cooled by liquid nitrogen, and then the temperature was permitted to rise to room temperature, going from near -34 to 19{sup 0}C (-30 to 67{sup 0}F) in 75 min. A spherical lithium neutron detector, 21 cm from the palladium gave an audible indication of neutron levels approximately equal to, but above, background. A second experiment used a deuterium ion beam (1 keV) that bombarded a palladium target.

  19. Silicate Based Glass Formulations for Immobilization of U.S. Defense Wastes Using Cold Crucible Induction Melters

    SciTech Connect (OSTI)

    Smith, Gary L.; Kim, Dong-Sang; Schweiger, Michael J.; Marra, James C.; Lang, Jesse B.; Crum, Jarrod V.; Crawford, Charles L.; Vienna, John D.

    2014-05-22

    The cold crucible induction melter (CCIM) is an alternative technology to the currently deployed liquid-fed, ceramic-lined, Joule-heated melter for immobilizing of U.S. tank waste generated from defense related reprocessing. In order to accurately evaluate the potential benefits of deploying a CCIM, glasses must be developed specifically for that melting technology. Related glass formulation efforts have been conducted since the 1990s including a recent study that is first documented in this report. The purpose of this report is to summarize the silicate base glass formulation efforts for CCIM testing of U.S. tank wastes. Summaries of phosphate based glass formulation and phosphate and silicate based CCIM demonstration tests are reported separately (Day and Ray 2013 and Marra 2013, respectively). Combined these three reports summarize the current state of knowledge related to waste form development and process testing of CCIM technology for U.S. tank wastes.

  20. Analysis of a double-ended cold-leg break simulation: THTF Test 3. 05. 5B. [PWR

    SciTech Connect (OSTI)

    Craddick, W.G.; Pevey, R.E.

    1982-09-01

    On July 3, 1980, an experiment was performed in the Oak Ridge National Laboratory Thermal-Hydraulic Test Facility that simulated a double-ended cold-leg break pressurized-water reactor (PWR) accident. Analysis of the experiment revealed that nuclear fuel rods exposed to the same hydrodynamic environment as that which existed in the experiment would have departed from nucleate boiling both earlier and later than the fuel rod simulator (FRS), depending on the size of the gap between the nuclear fuel pellets and cladding and on the initial power of the nuclear fuel rod. Comparison of the results of the current experiment, which used an FRS bundle with geometry similar to 17 x 17 PWR fuel assemblies, to the results of earlier experiments, which used an FRS bundle with geometry similar to 15 x 15 PWR fuel assemblies, revealed no differences that can be attributed to the difference in geometries.

  1. Phase mixing of upper hybrid oscillations in a cold inhomogeneous plasma placed in an inhomogeneous magnetic field

    SciTech Connect (OSTI)

    Sarkar, Anwesa; Maity, Chandan; Chakrabarti, Nikhil

    2013-05-15

    We study phase mixing/wave breaking phenomena of upper hybrid modes in a cold inhomogeneous plasma placed in an inhomogeneous magnetic field. Inhomogeneities both in the background ion density and magnetic field profile are treated as periodic in space but independent in time. The Lagrangian fluid description is employed to obtain an exact solution of this fully nonlinear problem. It is demonstrated that the upper hybrid modes, excited by an initial local charge imbalance, break via phase mixing, induced by the inhomogeneities. It is also shown that it is possible to avoid phase mixing in excited upper hybrid oscillations in an inhomogeneous plasma containing a finite amplitude ion density fluctuation. The choice of external magnetic field is shown to have a key role in avoiding phase mixing in such oscillations. The relevance of our investigation regarding the particle acceleration in an inhomogeneous plasma has also been discussed.

  2. Aberration corrected 1.2-MV cold field-emission transmission electron microscope with a sub-50-pm resolution

    SciTech Connect (OSTI)

    Akashi, Tetsuya; Takahashi, Yoshio; Tanigaki, Toshiaki Shimakura, Tomokazu; Kawasaki, Takeshi; Furutsu, Tadao; Shinada, Hiroyuki; Osakabe, Nobuyuki; Mller, Heiko; Haider, Maximilian; Tonomura, Akira

    2015-02-16

    Atomic-resolution electromagnetic field observation is critical to the development of advanced materials and to the unveiling of their fundamental physics. For this purpose, a spherical-aberration corrected 1.2-MV cold field-emission transmission electron microscope has been developed. The microscope has the following superior properties: stabilized accelerating voltage, minimized electrical and mechanical fluctuation, and coherent electron emission. These properties have enabled to obtain 43-pm information transfer. On the bases of these performances, a 43-pm resolution has been obtained by correcting lens aberrations up to the third order. Observations of GaN [411] thin crystal showed a projected atomic locations with a separation of 44?pm.

  3. THE ABSENCE OF COLD DUST AND THE MINERALOGY AND ORIGIN OF THE WARM DUST ENCIRCLING BD +20 307

    SciTech Connect (OSTI)

    Weinberger, A. J.; Becklin, E. E.; Zuckerman, B.; Song, I. E-mail: becklin@astro.ucla.edu E-mail: song@uga.edu

    2011-01-10

    Spitzer Space Telescope photometry and spectroscopy of BD +20 307 show that all of the dust around this remarkable Gyr-old spectroscopic binary arises within 1 AU. No additional cold dust is needed to fit the infrared excess. Peaks in the 10 and 20 {mu}m spectrum are well fit with small silicates that should be removed on a timescale of years from the system. This is the dustiest star known for its age, which is {approx}>1 Gyr. The dust cannot arise from a steady-state collisional cascade. A catastrophic collision of two rocky, planetary-scale bodies in the terrestrial zone is the most likely source for this warm dust because it does not require a reservoir of planetesimals in the outer system.

  4. Natural Recharge to the Unconfined Aquifer System on the Hanford Site from the Greater Cold Creek Watershed: Progress Report 2004

    SciTech Connect (OSTI)

    Waichler, Scott R.; Wigmosta, Mark S.; Coleman, Andre M.

    2004-09-14

    Movement of contaminants in groundwater at the Hanford Site is heavily dependent on recharge to the unconfined aquifer. As the effects of past artificial discharges dissipate, the water table is expected to return to more natural conditions, and natural recharge will become the driving force when evaluating future groundwater flow conditions and related contaminant transport. Previous work on the relationship of natural recharge to groundwater movement at the Hanford Site has focused on direct recharge from infiltrating rainfall and snowmelt within the area represented by the Sitewide Groundwater Model (SGM) domain. However, part of the groundwater recharge at Hanford is provided by flow from Greater Cold Creek watershed (GCC), a large drainage area on the western boundary of the Hanford Site that includes Cold Creek Valley, Dry Creek Valley, and the Hanford side of Rattlesnake Mountain. This study was undertaken to estimate the recharge from GCC, which is believed to enter the unconfined aquifer as both infiltrating streamflow and shallow subsurface flow. To estimate recharge, the Distributed Hydrology-Soil-Vegetation Model (DHSVM) was used to simulate a detailed water balance of GCC from 1956 to 2001 at a spatial resolution of 200~m and a temporal resolution of one hour. For estimating natural recharge to Hanford from watersheds along its western and southwestern boundaries, the most important aspects that need to be considered are 1)~distribution and relative magnitude of precipitation and evapotranspiration over the watershed, 2)~streamflow generation at upper elevations and infiltration at lower elevations during rare runoff events, and 3)~permeability of the basalt bedrock surface underlying the soil mantle.

  5. The non-uniform early structural response of globular proteins to cold denaturing conditions: A case study with Yfh1

    SciTech Connect (OSTI)

    Chatterjee, Prathit; Bagchi, Sayan E-mail: s.bagchi@ncl.res.in; Sengupta, Neelanjana E-mail: s.bagchi@ncl.res.in

    2014-11-28

    The mechanism of cold denaturation in proteins is often incompletely understood due to limitations in accessing the denatured states at extremely low temperatures. Using atomistic molecular dynamics simulations, we have compared early (nanosecond timescale) structural and solvation properties of yeast frataxin (Yfh1) at its temperature of maximum stability, 292 K (T{sub s}), and the experimentally observed temperature of complete unfolding, 268 K (T{sub c}). Within the simulated timescales, discernible global level structural loss at T{sub c} is correlated with a distinct increase in surface hydration. However, the hydration and the unfolding events do not occur uniformly over the entire protein surface, but are sensitive to local structural propensity and hydrophobicity. Calculated infrared absorption spectra in the amide-I region of the whole protein show a distinct red shift at T{sub c} in comparison to T{sub s}. Domain specific calculations of IR spectra indicate that the red shift primarily arises from the beta strands. This is commensurate with a marked increase in solvent accessible surface area per residue for the beta-sheets at T{sub c}. Detailed analyses of structure and dynamics of hydration water around the hydrophobic residues of the beta-sheets show a more bulk water like behavior at T{sub c} due to preferential disruption of the hydrophobic effects around these domains. Our results indicate that in this protein, the surface exposed beta-sheet domains are more susceptible to cold denaturing conditions, in qualitative agreement with solution NMR experimental results.

  6. From Cold War to cold vessels

    SciTech Connect (OSTI)

    Melrath, C.

    1996-09-01

    This article describes a former Soviet weapons plant which is converted to produce cryogenic vessels and other peaceful cylinders. In 1995, Byelocorp Scientific Inc. (BSI), a New York-based firm that specializes in transferring technologies developed in the former Soviet Union, began converting a huge military defense plant in Kazakhstan into civilian-industrial use. The nearly 750,000-square-foot factory in Almaty, the capital of the former Soviet republic, was previously used to manufacture torpedo shells and ballistic rocket casings. The old defense plant, which was known as Gidromash, will now manufacture cylinders of a kinder, gentler variety--cryogenic vessels. The Kazakhstan operation is being managed jointly with Supco Srl., an Italian manufacturing, engineering, and construction company. With financing from the US Department of Defense, BSI, Supco, and the Kazakhstan government, a new joint venture called Byelkamit (a combination of Byelocorp, Kazakhstan, America, and Italy) was established.

  7. Status of Environmental Management Initiatives to Accelerate the Reduction of Environmental Risks and Challenges Posed by the Legacy of the Cold War

    Broader source: Energy.gov [DOE]

    This Report to Congress was prepared pursuant to section 3130 of the National Defense Authorization Act (NDAA) for Fiscal Year (FY) 2008, and summarized the EM program and initiatives to accelerate the reduction of environmental risks and challenges posed by the legacy of the Cold War.

  8. What do we do, if some of the MICE magnets can't be kept cold using the two-stage coolers?

    SciTech Connect (OSTI)

    Green, Michael A.

    2011-01-26

    Tests of the spectrometer solenoids have not been encouraging in terms of keeping the magnets cold using three 1.5 W (at 4.2 K) coolers. The spectrometer solenoids are being rebuilt with additional cooling capacity at 4.2 K. It is hoped that there will be sufficient 4.2 K cooling to keep the magnets cold. The spectrometer solenoids can be kept cold using liquid helium (up to a boil-off of 20 liters per day). This option does not apply for the other magnets in the MICE cooling channel, because there is not enough liquid helium storage within the magnet cold mass. It is important that the MICE collaboration ask the question, “How do we keep the MICE cooling channel magnets cold, if there isn’t sufficient cooling from the 4.2 K coolers?” This report discusses the cooling requirements at both 40 K and 4.2 K for all three types of MICE cooling channel magnets. This report discusses the steps that must be taken in the magnet fabrication to permit the magnets to be cooled using a small (20 to 40 W) external 4.2 K Claude cycle refrigerator. One must also ask the question as to whether there is enough excess capacity in the decay solenoid refrigerator to cool some of the MICE magnets. A plan for cooling the magnets using a Linde 1400 series refrigerator is presented. A plan for increasing the 4.4 K refrigeration from the existing decay solenoid refrigerator is also presented.

  9. Extended Cold Testing of a Russian Pulsating Mixer Pump at the Oak Ridge National Laboratory, Oak Ridge, Tennessee

    SciTech Connect (OSTI)

    Lewis, BE

    2002-12-23

    The effectiveness of a mixer is dependent on the size of the tank to be mixed, the characteristics of the waste, and the operating conditions. Waste tanks throughout the U.S. Department of Energy Complex require mixing and mobilization systems capable of (1) breaking up and suspending materials that are difficult to mix and pump, without introducing additional liquids into the tank; (2) complementing and augmenting the performance of other remotely operated and/or robotic waste retrieval systems; and (3) operating in tanks with various quantities of waste. The Oak Ridge Russian pulsating mixer pump (PMP) system was designed with the flexibility to permit deployment in a variety of cylindrical tanks. The PMP was installed at the Tanks Technology Cold Test Facility at the Oak Ridge National Laboratory (ORNL) to assess the performance of the system over an extended range of operating conditions, including supply pressures up to 175 psig. Previously conducted cold tests proved the applicability of the PMP for deployment in ORNL gunite tank TH-4. The previous testing and hot demonstrations had been limited to operating at air supply pressures of <100 psig. The extended cold testing of the Russian PMP system showed that the system was capable of mobilizing waste simulants in tanks in excess of 20-ft diam. The waste simulant used in these tests was medium-grain quartz sand. The system was successfully installed, checked out, and operated for 406 pulse discharge cycles. Only minor problems (i.e., a sticking air distributor valve and a few system lockups) were noted. Some improvements to the design of the air distributor valve may be needed to improve reliability. The air supply requirements of the PMP during the discharge cycle necessitated the operation of the system in single pulse discharge cycles to allow time for the air supply reservoir to recharge to the required pressure. During the test program, the system was operated with sand depths of 2, 4, and 4.5 in.; at operating pressures from 100 to 175 psig; and elevations of 1 to 10 in. off the floor of the mock tank. The higher operating pressures resulted in larger values for the effective cleaning radius (ECR). The maximum observed ECR value, 144 in., occurred with the PMP elevated {approx}4 in. off the floor of the mock tank; a 2-in. layer of sand as the waste simulant, and 175-psig air supply pressure. Tests were conducted both within the confines of the 20-ft diam mock tank (confined) and with a portion of the tank wall removed (unconfined). The mixing mode during the confined tests changed from direct to indirect as the PMP was elevated above 4 in. off the floor of the mock tank. The direct mode of mixing pushes solids toward the wall of the waste tank, while the indirect mode tends to push solids toward the center of the tank. The mixing mode did not change during tests conducted in the unconfined tank. Changing the mode of mixing from direct to indirect should have a beneficial effect on the amount of solids mobilized and retrieved from a waste tank.

  10. Technology Development Plan: Geotechnical survey systems for OTEC (Ocean Thermal Energy Conversion) cold water pipes: Final subcontract report

    SciTech Connect (OSTI)

    Valent, P.J.; Riggins, M.

    1989-04-01

    This report provides an overview of current and developing technologies and techniques for performing geotechnical investigations for siting and designing Cold Water Pipes (CWP) for shelf-resting Ocean Thermal Energy Conversion (OTEC) power plants. The geotechnical in situ tools used to measure the required parameters and the equipment/systems used to deploy these tools are identified. The capabilities of these geotechnical tools and deployment systems are compared to the data requirements for the CWP foundation/anchor design, and shortfalls are identified. For the last phase of geotechnical data gathering for design, a drillship will be required to perform soil boring work, to obtain required high-quality sediment samples for laboratory dynamic testing, and to perform deep-penetration in situ tests. To remedy shortfalls and to reduce the future OTEC CWP geotechnical survey costs, it is recommended that a seafloor-resting machine be developed to advance the friction cone penetrometer, and also probably a pressuremeter, to provide geotechnical parameters to shallow subseafloor penetrations on slopes of 35/degree/ and in water depths to 1300 m. 74 refs., 19 figs., 6 tabs.

  11. Assessment of US shipbuilding current capability to build a commercial OTEC platform and a cold water pipe

    SciTech Connect (OSTI)

    Komelasky, M. C.

    1980-03-01

    Lowry and Hoffman Associates Inc. (LHA) performed for ORI an analysis of the shipbuilding requirements for constructing an OTEC plant, and the available shipyard assets which could fulfill these requirements. In addition, several shipyards were queried concerning their attitudes towards OTEC. In assessing the shipbuilding requirements for an OTEC plant, four different platform configurations were studied and four different designs of the cold water pipe (CWP) were examined. The platforms were: a concrete ship design proposed by Lockheed; concrete spar designs with internal heat exchangers (IHE) (Rosenblatt) and external heat exchangers (XHE) (Lockheed); and a steel ship design proposed by Gibbs and Cox. The types of materials examined for CWP construction were: steel, fiber reinforced plastic (FPR), elastomer, and concrete. The report is organized io three major discussion areas. All the construction requirements are synthesized for the four platforms and CWPs, and general comments are made concerning their availability in the US. Specific shipbuilders facilities are reviewed for their applicability to building an OTEC plant, an assessment of the shipyards general interest in the OTEC program is presented providing an insight into their nearterm commercial outlook. The method of determining this interest will depend largely on a risk analysis of the OTEC system. Also included are factors which may comprise this analysis, and a methodology to ascertain the risk. In the appendices, various shipyard specifications are presented, shipyard assessment matrices are given, graphs of various shipyard economic outlooks are provided, and definitions of the risk factors are listed. (WHK)

  12. Building America Case Study: Advanced Extended Plate and Beam Wall System in a Cold-Climate House, Mount Joy, Pennsylvania

    SciTech Connect (OSTI)

    2016-01-01

    This report presents the design and evaluation of a innovative wall system. This highly insulated (high-R) light-frame wall system for use above grade in residential buildings is referred to as Extended Plate & Beam (EP&B). The EP&B design is the first of its kind to be featured in a new construction test house (NCTH) for the DOE Building America program. The EP&B wall design integrates standard building methods and common building products to construct a high-R wall that minimizes transition risks and costs to builders. The EP&B design combines optimized framing with integrated rigid foam sheathing to increase the wall system's R-value and reduce thermal bridging. The foam sheathing is installed between the wall studs and structural wood sheathing. The exterior wood sheathing is attached directly to a framing extension formed by extended top and bottom plates. The exterior wood sheathing can dry to the exterior and provides bracing, a clear drainage plane and flashing surface for window and door openings, and a nailing surface for siding attachment. With support of the DOE Building America program, Home Innovation Research Labs partnered with Lancaster County Career and Technology Center (LCCTC) to build a NCTH in Lancaster, PA to demonstrate the EP&B wall design in a cold climate (IECC climate zone 5A). The results of the study confirmed the benefits of the systems and the viability of its integration into the house construction process.

  13. Densification of alkoxide-derived fine silica powder compact by ultra-high-pressure cold isostatic pressing

    SciTech Connect (OSTI)

    Kamiya, Hidehiro . Dept. of Chemical Engineering); Suzuki, Hisao ); Kato, Daisuke; Jimbo, Genji . Dept. of Chemical Engineering)

    1993-01-01

    Powder compacts of alkoxide-derived fine silica powders were consolidated into a highly dense and uniform structure by ultra-high-pressure cold isostatic pressing of granules with controlled structure. The diameters of spherical and nearly monosized amorphous silica particles, prepared from metal alkoxide, were successfully controlled in the range of 9 to 760 nm by varying the concentration of ammonia. Close-packed granules of these powders were produced by spray drying. These powders were isostatically pressed up to 1 GPa at room temperature. Although the average particle diameter was less than 100 nm, the maximum relative density of the compacts was more than 78% of theoretical density. The optimum particle size to obtain highly dense compacts was in the range of 30 to 300 nm at 1 GPa. Furthermore, the ratio of mode pore diameter in these compacts to particle diameter was less than 0.155, which corresponded to the minimum ratio of calculated three-particle pore channel radii for hexagonal close packing. Viscous deformation of particles under ultra-high isostatic pressure played an important role in the densification of the compacts.

  14. Investigation of Diesel combustion using multiple injection strategies for idling after cold start of passenger-car engines

    SciTech Connect (OSTI)

    Payri, F.; Broatch, A.; Salavert, J.M.; Martin, J.

    2010-10-15

    A comprehensive investigation was carried out in order to better understand the combustion behaviour in a low compression ratio DI Diesel engine when multiple injection strategies are applied just after the engine cold starts in low temperature conditions (idling). More specifically, the aim of this study was twofold: on one hand, to understand the effect of the multiple injection strategies on the indicated mean effective pressure; on the other hand, to contribute to the understanding of combustion stability characterized by the coefficient of variation of indicated mean effective pressure. The first objective was fulfilled by analyzing the rate of heat release obtained by in-cylinder pressure diagnosis. The results showed that the timing of the pilot injection closest to the main injection was the most influential parameter based on the behaviour of the rate of heat release (regardless of the multiple injection strategy applied). For the second objective, the combustion stability was found to be correlated with the combustion centroid angle. The results showed a trend between them and the existence of a range of centroid angles where the combustion stability is strong enough. In addition, it was also evident that convenient split injection allows shifting the centroid to such a zone and improves combustion stability after start. (author)

  15. RF thermal and new cold part design studies on TTF-III input coupler for Project-X

    SciTech Connect (OSTI)

    Pei, Shilun; Adolphsen, Chris E.; Li, Zenghai; Solyak, Nikolay A.; Gonin, Ivan V.

    2015-05-15

    An RF power coupler is one of the key components in a superconducting (SC) linac. It provides RF power to the SC cavity and interconnects different temperature layers (1.8 K, 4.2 K, 70 K and 300 K). The TTF-III coupler is one of the most promising candidates for the High Energy (HE) linac of Project X, but it cannot meet the average power requirements because of the relatively high temperature rise on the warm inner conductor, so some design modifications will be required. In this paper, we describe our simulation studies on the copper coating thickness on the warm inner conductor with RRR values of 10 and 100. Our purpose is to rebalance the dynamic and static loads, and finally lower the temperature rise along the warm inner conductor. Additionally, to get stronger coupling, better power handling and less multipacting probability, one new cold part design was proposed using a 60 mm coaxial line; the corresponding multipacting simulation studies have also been investigated.

  16. T invariance and T-odd asymmetries for the cold-polarized-neutron-induced fission of nonoriented nuclei

    SciTech Connect (OSTI)

    Kadmensky, S. G., E-mail: kadmensky@phys.vsu.ru [Voronezh State University (Russian Federation); Bunakov, V. E. [National Research Center Kurchatov Institute, Petersburg Nuclear Physics Institute (Russian Federation); Titova, L. V. [Voronezh State University (Russian Federation)

    2014-12-15

    It is shown that the coefficients D{sup exp} for all T-odd asymmetries observed experimentally in the cross sections for the reactions of cold-polarized-neutron-induced fission of nonoriented target nuclei (which involves the emission of prescission and evaporated particles) comply in shape and scale with the coefficients D{sup theor} calculated for the analogous asymmetries on the basis of quantum-mechanical nuclear-fission theory for T-invariant Hamiltonians of fissile systems. It is also shown that the asymmetries in question arise upon taking into account the effect of (i) the interference between the fission amplitudes of s- and p-wave resonances of a polarized fissile compound nucleus formed in the aforementioned reactions; (ii) the collective rotation of the compound nucleus in question (this rotation entails a change in the angular distributions of fission fragments and third particles); and (iii) the wriggling vibrations of this compound nucleus in the vicinity of its scission point, which lead to the appearance of high aligned spins of fission fragments, with the result that the emission of neutrons and photons evaporated from these fragments becomes anisotropic. The possible contribution of T-noninvariant interactions to the formation of the T-odd asymmetries under analysis is estimated by using the results obtained in experimentally testing the detailed-balance principle, (P-A) theorem, and T invariance of cross sections for elastic proton-proton and proton-neutron scattering.

  17. Structural Design and Analysis for a Double-Band Cold Mass Support of the MICE Coupling Magnet

    SciTech Connect (OSTI)

    Green, Michael A; Wu, Hong; Liu, X. K.; Wang, Li; Li, S. Y.; Guo, XingLong; Pan, Heng; Xu, FengYu

    2009-07-01

    The cooling channel of Muon Ionization Cooling Experiment (MICE) consists of eighteen superconducting solenoid coils, which are magnetically hooked together. A pair ofcoupling magnets operating at 4 K is applied to produce up to .6 T magnetic field on the magnet centerline to keep muon beam within the RF cavity windows. The peak magnetic force on the coupling magnet from other magnets in the MICE channel is up to 500 kN inlongitudinal direction, and the requirements for magnet center and axis azimuthal angle at 4 K are stringent. A self-centered double-band cold mass support system with intermediatethermal interruption is applied for the coupling magnet. The physical center of the magnet does not change as it is cooled down from 300 K to 4.2 K with this support system. In this paper the design parameters of the support system are discussed. The integral analysis of the support system using FEA method was carried out to etermine the tension forces in bands when various loads are applied. The magnet centre displacement and concentricity deviation form the axis of the warm bore are obtained, and the peak tension in support bands is also determined according to the simulation results.

  18. Realization of a SU(2)xSU(6) System of Fermions in a Cold Atomic Gas

    SciTech Connect (OSTI)

    Taie, Shintaro; Takasu, Yosuke; Sugawa, Seiji; Tsujimoto, Takuya; Murakami, Ryo [Department of Physics, Graduate School of Science, Kyoto University, 606-8502 (Japan); Yamazaki, Rekishu; Takahashi, Yoshiro [Department of Physics, Graduate School of Science, Kyoto University, 606-8502 (Japan); CREST, JST, 4-1-8 Honcho Kawaguchi, Saitama 332-0012 (Japan)

    2010-11-05

    We report the realization of a novel degenerate Fermi mixture with an SU(2)xSU(6) symmetry in a cold atomic gas. We successfully cool the mixture of the two fermionic isotopes of ytterbium {sup 171}Yb with the nuclear spin I=1/2 and {sup 173}Yb with I=5/2 below the Fermi temperature T{sub F} as 0.46T{sub F} for {sup 171}Yb and 0.54T{sub F} for {sup 173}Yb. The same scattering lengths for different spin components make this mixture featured with the novel SU(2)xSU(6) symmetry. The nuclear spin components are separately imaged by exploiting an optical Stern-Gerlach effect. In addition, the mixture is loaded into a 3D optical lattice to implement the SU(2)xSU(6) Hubbard model. This mixture will open the door to the study of novel quantum phases such as a spinor Bardeen-Cooper-Schrieffer-like fermionic superfluid.

  19. Assessment of RELAP/MOD3 using BETHSY 6.2TC 6-inch cold leg side break comparative test

    SciTech Connect (OSTI)

    Chung, Young-Jong; Jeong, Jae-Jun; Chang, Won-Pyo; Kim, Dong-Su

    1996-10-01

    This report presents the results of the RELAP5/MOD3 Version 7j assessment on BETHSY 6.2TC. BETHSY 6.2TC test corresponding to a six inch cold leg break LOCA of the Pressurizer Water Reactor(PWR). The primary objective of the test was to provide reference data of two facilities of different scales (BETHSY and LSTF facility). On the other hand, the present calculation aims at analysis of RELAP5/N4OD3 capability on the small break LOCA simulation, The results of calculation have shown that the RELAP5/MOD3 reasonably predicts occurrences as well as trends of the major phenomena such as primary pressure, timing of loop seal clearing, liquid hold up, etc. However, some disagreements also have been found in the predictions of loop seal clearing, collapsed core water level after loop seal clearing, and accumulator injection behaviors. For better understanding of discrepancies in same predictions, several sensitivity calculations have been performed as well. These include the changes of two-phase discharge coefficient at the break junction and some corrections of the interphase drag term. As result, change of a single parameter has not improved the overall predictions and it has been found that the interphase drag model has still large uncertainties.

  20. REACTIVE DESORPTION AND RADIATIVE ASSOCIATION AS POSSIBLE DRIVERS OF COMPLEX MOLECULE FORMATION IN THE COLD INTERSTELLAR MEDIUM

    SciTech Connect (OSTI)

    Vasyunin, A. I.; Herbst, Eric E-mail: eh2ef@virginia.edu

    2013-05-20

    The recent discovery of terrestrial-type organic species such as methyl formate and dimethyl ether in the cold interstellar gas has proved that the formation of organic matter in the Galaxy begins at a much earlier stage of star formation than was previously thought. This discovery represents a challenge for astrochemical modelers. The abundances of these molecules cannot be explained by the previously developed ''warm-up'' scenario, in which organic molecules are formed via diffusive chemistry on surfaces of interstellar grains starting at 30 K, and then released to the gas at higher temperatures during later stages of star formation. In this article, we investigate an alternative scenario in which complex organic species are formed via a sequence of gas-phase reactions between precursor species formed on grain surfaces and then ejected into the gas via efficient reactive desorption, a process in which non-thermal desorption occurs as a result of conversion of the exothermicity of chemical reactions into the ejection of products from the surface. The proposed scenario leads to reasonable if somewhat mixed results at temperatures as low as 10 K and may be considered as a step toward the explanation of abundances of terrestrial-like organic species observed during the earliest stages of star formation.

  1. A dominant role of oxygen additive on cold atmospheric-pressure He + O{sub 2} plasmas

    SciTech Connect (OSTI)

    Yang, Aijun; Liu, Dingxin E-mail: xhw@mail.xjtu.edu.cn; Rong, Mingzhe; Wang, Xiaohua E-mail: xhw@mail.xjtu.edu.cn; Kong, Michael G.

    2014-08-15

    We present in this paper how oxygen additive impacts on the cold atmospheric-pressure helium plasmas by means of a one-dimensional fluid model. For the oxygen concentration [O{sub 2}]?>??0.1%, the influence of oxygen on the electron characteristics and the power dissipation becomes important, e.g., the electron density, the electron temperature in sheath, the electron-coupling power, and the sheath width decreasing by 1.6 to 16 folds with a two-log increase in [O{sub 2}] from 0.1% to 10%. Also the discharge mode evolves from the ? mode to the ? mode. The reactive oxygen species are found to peak in the narrow range of [O{sub 2}]?=?0.4%0.9% in the plasmas, similar to their power-coupling values. This applies to their wall fluxes except for those of O* and O{sub 2}{sup ?}. These two species have very short lifetimes, thus only when generated in boundary layers within several micrometers next to the electrode can contribute to the fluxes. The dominant reactive oxygen species and the corresponding main reactions are schematically presented, and their relations are quantified for selected applications.

  2. Effects of a random spatial variation of the plasma density on the mode conversion in cold, unmagnetized, and stratified plasmas

    SciTech Connect (OSTI)

    Jung Yu, Dae; Kim, Kihong

    2013-12-15

    We study the effects of a random spatial variation of the plasma density on the mode conversion of electromagnetic waves into electrostatic oscillations in cold, unmagnetized, and stratified plasmas. Using the invariant imbedding method, we calculate precisely the electromagnetic field distribution and the mode conversion coefficient, which is defined to be the fraction of the incident wave power converted into electrostatic oscillations, for the configuration where a numerically generated random density variation is added to the background linear density profile. We repeat similar calculations for a large number of random configurations and take an average of the results. We obtain a peculiar nonmonotonic dependence of the mode conversion coefficient on the strength of randomness. As the disorder increases from zero, the maximum value of the mode conversion coefficient decreases initially, then increases to a maximum, and finally decreases towards zero. The range of the incident angle in which mode conversion occurs increases monotonically as the disorder increases. We present numerical results suggesting that the decrease of mode conversion mainly results from the increased reflection due to the Anderson localization effect originating from disorder, whereas the increase of mode conversion of the intermediate disorder regime comes from the appearance of many resonance points and the enhanced tunneling between the resonance points and the cutoff point. We also find a very large local enhancement of the magnetic field intensity for particular random configurations. In order to obtain high mode conversion efficiency, it is desirable to restrict the randomness close to the resonance region.

  3. New Whole-House Solutions Case Study: The Performance House: A Cold Climate Challenge Home, Old Greenwich, Connecticut

    SciTech Connect (OSTI)

    2013-11-01

    By working with builder partners on test homes, researchers from the U.S. Department of Energys Building America program can vet whole-house building strategies and avoid potential unintended consequences of implementing untested solution packages on a production scale. To support this research, Building America team Consortium for Advanced Residential Buildings (CARB) partnered with Preferred Builders Inc. on a high-performance test home in Old Greenwich, Connecticut. The philosophy and science behind the 2,700 ft2 Performance House was based on the premise that homes should be safe, healthy, comfortable, durable, efficient, and adaptable to the needs of homeowners. The technologies and strategies used in the Performance House were best practices rather than cutting edge, with a focus on simplicity in construction, maintenance, and operation. Achieving 30% source energy savings compared with a home built to the 2009 International Energy Conservation Code in the cold climate zone requires that nearly all components and systems be optimized. Careful planning and design are critical. The end result was a DOE Challenge Home that achieved a Home Energy Rating System (HERS) Index Score of 20 (43 without photovoltaics [PV]).

  4. W(310) cold-field emission characteristics reflecting the vacuum states of an extreme high vacuum electron gun

    SciTech Connect (OSTI)

    Cho, Boklae; Shigeru, Kokubo; Oshima, Chuhei

    2013-01-15

    An extremely high vacuum cold-field electron emission (CFE) gun operating at pressures ranging from {approx}10{sup -8} Pa to {approx}10{sup -10} Pa was constructed. Only the CFE current emitting from W(310) surfaces revealed the existence of a 'stable region' with high current angular density just after tip flash heating. In the 'stable region,' the CFE current was damped very slowly. The presence of non-hydrogen gas eliminated this region from the plot. Improvement of the vacuum prolonged the 90% damping time of the CFE current from {approx}10 min to 800 min. The current angular density I{sup Prime} of CFE current was 60 and 250 {mu}A/sr in the 'stable region' for total CFE currents of 10 and 50 {mu}A, respectively. These results were about three times larger than I{sup Prime} when measured after the complete damping of the CFE current. The CFE gun generated bright scanning transmission electron microscopy images of a carbon nanotube at 30 kV.

  5. Stark-tuned Foerster resonance and dipole blockade for two to five cold Rydberg atoms: Monte Carlo simulations for various spatial configurations

    SciTech Connect (OSTI)

    Ryabtsev, I. I.; Tretyakov, D. B.; Beterov, I. I.; Entin, V. M.; Yakshina, E. A.

    2010-11-15

    Results of numerical Monte Carlo simulations for the Stark-tuned Fo{center_dot}{center_dot}rster resonance and dipole blockade between two to five cold rubidium Rydberg atoms in various spatial configurations are presented. The effects of the atoms' spatial uncertainties on the resonance amplitude and spectra are investigated. The feasibility of observing coherent Rabi-like population oscillations at a Fo{center_dot}{center_dot}rster resonance between two cold Rydberg atoms is analyzed. Spectra and the fidelity of the Rydberg dipole blockade are calculated for various experimental conditions, including nonzero detuning from the Fo{center_dot}{center_dot}rster resonance and finite laser linewidth. The results are discussed in the context of quantum-information processing with Rydberg atoms.

  6. Ion sources with arc-discharge plasma box driven by directly heated LaB{sub 6} electron emitter or cold cathode (invited)

    SciTech Connect (OSTI)

    Ivanov, Alexander A.; Davydenko, Vladimir I.; Deichuli, Petr P.; Shulzhenko, Grigori I.; Stupishin, Nikolay V.

    2008-02-15

    In the Budker Institute, Novosibirsk, an ion source with arc-discharge plasma box has been developed in the recent years for application in thermonuclear devices for plasma diagnostics. Several modifications of the ion source were provided with extracted current ranging from 1 to 7 A and pulse duration of up to 4 s. Initially, the arc-discharge plasma box with cold cathode was used, with which pulse duration is limited to 2 s by the cathode overheating and sputtering in local arc spots. Recently, a directly heated LaB{sub 6} electron emitter was employed instead, which has extended lifetime compared to the cold cathode. In the paper, characteristics of the beam produced with both arrangements of the plasma box are presented.

  7. Negative results and positive artifacts observed in a comprehensive search for neutrons from (cold fusion) using a multidetector system located underground

    SciTech Connect (OSTI)

    Ewing, R.I.; Butler, M.A.; Schirber, J.E.; Ginley, D.S. )

    1989-11-01

    This paper reports on a search for neutrons from deuterium cold fusion systems (both electrochemical and high-pressure gas cells) conducted in an underground laboratory using three highly sensitive neutron detectors composed of {sup 3}He gas proportional counter tubes embedded in polyethylene moderators. Any neutron emission from a test cell would be simultaneously observed in all three detectors in a known proportion. The counting system can detect random, continuous emission at a rate of {lt} 100 n/h, and short bursts of as few as 35 neutrons. None of the cold fusion systems tested emitted neutrons at these levels. Occasional anomalous groups of counts were observed in individual detectors that closely mimicked both continuous and burst emission. These anomalies were identified as spurious detector artifacts rather than true detection, because counts were not observed in the appropriate proportion in all three detectors.

  8. Preliminary design studies for a (D-D) or (D-T) driven cold fusion-fission (hybrid) reactor with metallic uranium

    SciTech Connect (OSTI)

    Sahin, S. ); Baltacioglu, E.; Yapici, H. )

    1991-01-01

    Based on the possibility of (D,D) fusion at room temperature in a heavy metal (palladium) matrix, a cold fusion-fission (hybrid) reactor design has been evaluated in this paper. The reactor is composed of a number of modular and uniform fuel lattices. The cold fusion neutrons induce fission reactions in the natural metallic uranium fuel, imbedded in the lattice. The neutron spectrum, and consequently the fission power density are nearly constant in the reactor core so that the rector performance becomes almost independent on the reactor size. The energy multiplication for each fusion neutron production in the (D,T) and (D,D) reactors are about 3.3 and 7.0, respectively. The (D,T) reactor mode is self-sufficient in respect to tritium breeding ratio (TBR = 1.2).

  9. A novel cold-regulated gene from Camellia sinensis, CsCOR1, enhances salt- and dehydration-tolerance in tobacco

    SciTech Connect (OSTI)

    Li, Xian-Wen; College of Life Science, Xinyang Normal University, Xinyang 464000; Key Laboratory of Horticultural Plant Biology of the Ministry of Education, Huazhong Agricultural University, Wuhan 430070 ; Feng, Zhi-Guo; Yang, Hui-Min; Zhu, Xiao-Pei; Liu, Jun; Key Laboratory of Horticultural Plant Biology of the Ministry of Education, Huazhong Agricultural University, Wuhan 430070 ; Yuan, Hong-Yu

    2010-04-02

    In present research, the full-length cDNA and the genomic sequence of a novel cold-regulated gene, CsCOR1, were isolated from Camellia sinensis L. The deduced protein CsCOR1 contains a hydrophobic N-terminus as a signal peptide and a hydrophilic C-terminal domain that is rich in glycine, arginine and proline. Two internal repetitive tridecapeptide fragments (HSVTAGRGGYNRG) exist in the middle of the C-terminal domain and the two nucleotide sequences encoding them are identical. CsCOR1 was localized in the cell walls of transgenic-tobaccos via CsCOR1::GFP fusion approach. The expression of CsCOR1 in tea leaves was enhanced dramatically by both cold- and dehydration-stress. And overexpression of CsCOR1 in transgenic-tobaccos improved obviously the tolerance to salinity and dehydration.

  10. Control mechanism for attenuation of thermal energy pulses using cold circulators in the cryogenic distribution system of fusion devices in tokamak configuration

    SciTech Connect (OSTI)

    Bhattacharya, R.; Sarkar, B.; Vaghela, H.; Shah, N.

    2014-01-29

    Operation and control of superconducting (SC) magnets in the fusion devices having tokamak configuration opens up the domain of varying peak thermal energy environment as a function of time, commensurate with the plasma pulses. The varied thermal energy environment, thus propagated to upstream of the cooling system, is responsible for the system level instability of the overall cryogenic system. The cryogenic distribution system, the regime of first impact point, therefore, has to be tuned so as to stay at the nearly stable zone of operation. The configuration of the cryogenic distribution system, considered in the present study, involves a liquid helium (LHe) bath as a thermal buffer, LHe submerged heat exchangers and cold circulator apart from the valves for implementations of the precise controls. The cold circulator supplies the forced flow supercritical helium, used for the cooling of SC magnets. The transients of the thermal energy pulses can be attenuated in the cryogenic distribution system by various methodologies. One of the adopted methodologies in the present study is with the precise speed control of the cold circulators. The adopted methodology is applied to various configurations of arrangements of internal components in the distribution system for obtaining system responses with superior attenuation of energy pulses. The process simulation approach, assumptions, considered inputs and constraints, process modeling with different configuration as well as results to accomplish the control scheme for the attenuation of the thermal energy pulses are described.

  11. THE CIRCUMGALACTIC MEDIUM OF MASSIVE GALAXIES AT z {approx} 3: A TEST FOR STELLAR FEEDBACK, GALACTIC OUTFLOWS, AND COLD STREAMS

    SciTech Connect (OSTI)

    Shen Sijing; Madau, Piero; Prochaska, J. Xavier [Department of Astronomy and Astrophysics, University of California, 1156 High Street, Santa Cruz, CA 95064 (United States); Guedes, Javiera [Institute for Astronomy, ETH Zurich, Wolgang-Pauli-Strasse 27, CH-8093 Zurich (Switzerland); Mayer, Lucio [Institute of Theoretical Physics, University of Zurich, Winterthurerstrasse 190, CH-9057 Zurich (Switzerland); Wadsley, James [Department of Physics and Astronomy, McMaster University, Hamilton, ON L8S 4M1 (Canada)

    2013-03-10

    We present new results on the kinematics, thermal and ionization state, and spatial distribution of metal-enriched gas in the circumgalactic medium (CGM) of massive galaxies at redshift {approx}3, using the Eris suite of cosmological hydrodynamic ''zoom-in'' simulations. The reference run adopts a blastwave scheme for supernova feedback that produces large-scale galactic outflows, a star formation recipe based on a high gas density threshold, metal-dependent radiative cooling, and a model for the diffusion of metals and thermal energy. The effect of the local UV radiation field is added in post-processing. The CGM (defined as all gas at R > 0.2 R{sub vir} = 10 kpc, where R{sub vir} is the virial radius) contains multiple phases having a wide range of physical conditions, with more than half of its heavy elements locked in a warm-hot component at T > 10{sup 5} K. Synthetic spectra, generated by drawing sightlines through the CGM, produce interstellar absorption-line strengths of Ly{alpha}, C II, C IV, Si II, and Si IV as a function of the galactocentric impact parameter (scaled to the virial radius) that are in broad agreement with those observed at high redshift by Steidel et al. The covering factor of absorbing material declines less rapidly with impact parameter for Ly{alpha} and C IV compared to C II, Si IV, and Si II, with Ly{alpha} remaining strong (W{sub Ly{alpha}} > 300 mA) to {approx}> 5 R{sub vir} = 250 kpc. Only about one third of all the gas within R{sub vir} is outflowing. The fraction of sightlines within one virial radius that intercept optically thick, N{sub H{sub I}}>10{sup 17.2} cm{sup -2} material is 27%, in agreement with recent observations by Rudie et al. Such optically thick absorption is shown to trace inflowing ''cold'' streams that penetrate deep inside the virial radius. The streams, enriched to metallicities above 0.01 solar by previous episodes of star formation in the main host and in nearby dwarfs, are the origin of strong (N{sub C{sub II}}>10{sup 13} cm{sup -2}) C II absorption with a covering factor of 22% within R{sub vir} and 10% within 2 R{sub vir}. Galactic outflows do not cause any substantial suppression of the cold accretion mode. The central galaxy is surrounded by a large O VI halo, with a typical column density N{sub O{sub VI}} {approx}> 10{sup 14} cm{sup -2} and a near unity covering factor maintained all the way out to 150 kpc. This matches the trends recently observed in star-forming galaxies at low redshift by Tumlinson et al. Our zoom-in simulations of this single system appear then to reproduce quantitatively the complex baryonic processes that determine the exchange of matter, energy, and metals between galaxies and their surroundings.

  12. Brominated Sorbents for Small Cold-Side ESPs, Hot-Side ESPs and Fly Ash Use in Concrete

    SciTech Connect (OSTI)

    Ronald Landreth

    2008-06-30

    This report summarizes the work conducted from September 16, 2005 through December 31, 2008 on the project entitled â??Brominated Sorbents for Small Cold-Side ESPs, Hot-Side ESPs and Fly Ash Use in Concreteâ?. The project covers testing at three host sites: Progress Energy H.F. Lee Station and the Midwest Generation Crawford and Will County Stations. At Progress Energy Lee 1, parametric tests were performed both with and without SO{sub 3} injection in order to determine the impact on the mercury sorbent performance. In addition, tests were performed on the hot-side of the air preheater, before the SO{sub 3} is injected, with H-PACâ?¢ sorbents designed for use at elevated temperatures. The BPACâ?¢ injection provided the expected mercury removal when the SO{sub 3} injection was off. A mercury removal rate due to sorbent of more than 80% was achieved at an injection rate of 8 lb/MMacf. The operation with SO{sub 3} injection greatly reduced the mercury sorbent performance. An important learning came from the injection of H-PACâ?¢ on the hot-side of the air preheater before the SO{sub 3} injection location. The H-PACâ?¢ injected in this manner appeared to be independent of the SO{sub 3} injection and provided better mercury removal than with injecting on the cold-side with SO{sub 3} injection. Consequently, one solution for plants like Lee, with SO{sub 3} injection, or plants with SO{sub 3} generated by the SCR catalyst, is to inject H-PACâ?¢ on the hot-side before the SO{sub 3} is in the flue gas. Even better performance is possible by injecting on the cold-side without the SO{sub 3}, however. During the parametric testing, it was discovered that the injection of B-PACâ?¢ (or H-PACâ?¢) was having a positive impact upon ESP performance. It was decided to perform a 3-day continuous injection run with B-PACâ?¢ in order to determine whether Lee 1 could operate without SO{sub 3} injection. If the test proved positive, the continuous injection would continue as part of the long-term test. The injection of B-PACâ?¢ did allow for the operation of Lee 1 without SO{sub 3} injection and the long-term test was conducted from March 8 through April 7, 2006. The total mercury removal for the 30-day long-term test, excluding the first day when SO{sub 3} was injected and the last day when a plain PAC was used, averaged 85%. The achievement of 85% Hg removal over the 30 days longterm test is another milestone in the history of achievement of the Albemarle Environmental f/k/a Sorbent Technologies Corporation B-PACâ?¢ sorbent. A clear indication of the impact of B-PACâ?¢ on opacity came at the end of the long-term test. It was hoped that Lee 1 could be operated for several days after the end of the long-term test. It took less than a day before the opacity began to increase. The discovery that B-PACâ?¢ can improve ESP performance while capturing a large amount of mercury is another milestone for the B-PACâ?¢ mercury sorbent. The parametric testing at the Midwest Generation Crawford Station was divided into two phases; the first using C-PACâ?¢, the concrete friendly sorbent, and the other using nonconcrete friendly materials. The first phase of the parametric tests was conducted before the long-term test. The second phase of the parametric testing was performed after the long-term test in order to avoid contaminating the fly ash containing the concrete friendly sorbents. The parametric test began with an injection rate of 1 lb/MMacf and, after a period to allow the mercury concentration to stabilize, the rate was increased to 3 lb/MMacf. The Hg removal for this test was about 60% due to sorbent and 69% total at the injection rate of 1 lb/MMacf and 80% due to sorbent and 84% total for the 3 lb/MMacf injection rate. The average total vapor phase mercury removal for the first 21 days of the long-term test was 82% at an injection rate o

  13. Solid Cold - B

    Office of Scientific and Technical Information (OSTI)

    ... These considerations led to a law relating the frequency of light in the furnace to its intensity, which in turn led to the idea that light energy was produced in units instead of ...

  14. Solid Cold - F

    Office of Scientific and Technical Information (OSTI)

    ... Thermal Physics, second edition by Charles Kittel and Herbert Kroemer Advanced ... Kittel and Kroemer review Debye's theory on pages 102-109 of their book; they don't deal ...

  15. Cold Hybrid Star Properties

    SciTech Connect (OSTI)

    Moshfegh, H. R.; Darehmoradi, M.; Mojarrad, M. Ghazanfari

    2011-10-28

    Properties of neutron stars with quark core are investigated. The equation of state of hadronic matter is calculated using Myers and Swiatecki two nucleon interaction within Thomas-Fermi semiclassical approximation (TF). For quark matter we employ The MIT bag model with constant and density dependent bag parameter. With use of the obtained equation of states we have calculated mass-radius relation of such hybrid stars.

  16. Solid Cold - D

    Office of Scientific and Technical Information (OSTI)

    D. Einstein's solution illustrated The problem with 19th-century atomic theory was the ... to the absolute temperature, as earlier theory implied, though if the temperature were ...

  17. Solid Cold - E

    Office of Scientific and Technical Information (OSTI)

    If the motion becomes very different, a large number of the small energy quanta have to be gained or lost, and that would look to our unaided senses like a continuous energy change ...

  18. Cold Weather Hazards

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    with good moisture wicking ability like polypropylene, wool blends or silk. Do not use cotton as an under layer fabric as it has poor wicking and insulating properties when wet....

  19. Solid Cold - C

    Office of Scientific and Technical Information (OSTI)

    How rarely depends on what the temperature is. Suppose our small object is one atom in a solid, and the larger object is all the rest of the solid. Under ordinary conditions, our ...

  20. Observation of cold Rb{sub 2} molecules trapped in an optical dipole trap using a laser-pulse-train technique

    SciTech Connect (OSTI)

    Menegatti, Carlos R.; Marangoni, Bruno S.; Marcassa, Luis G.

    2011-11-15

    In this work, we have developed and characterized a laser-pulse-train technique to observe cold Rb{sub 2} molecules trapped in an optical dipole trap. The molecules are produced in a magneto-optical trap, and then loaded into a crossed optical dipole trap. The time evolution of the molecular population is obtained by applying a laser pulse train, which photoionizes the ground-state molecules through intermediate molecular bands. Our results show that this technique allows us to obtain a faster data acquisition rate of the time evolution of the molecule population than other techniques.