Powered by Deep Web Technologies
Note: This page contains sample records for the topic "hydronic space heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Development of a cogenerating thermophotovoltaic powered combination hot water heater/hydronic boiler  

Science Journals Connector (OSTI)

A cogenerating thermophotovoltaic (TPV) device for hot water hydronic space heating and electric power generation was developed designed fabricated and tested under a Department of Energy contracted program. The device utilizes a cylindrical ytterbia superemissive ceramic fiber burner (SCFB) and is designed for a nominal capacity of 80 kBtu/hr. The burner is fired with premixed natural gas and air. Narrow band emission from the SCFB is converted to electricity by single crystal silicon (Si) photovoltaic (PV) arrays arranged concentrically around the burner. A three-way mixing valve is used to direct heated water to either the portable water storage tank radiant baseboard heaters or both. As part of this program QGI developed a microprocessor-based control system to address the safety issues as well as photovoltaic power management. Flame sensing is accomplished via the photovoltaics a technology borrowed from QGI’s Quantum Control™ safety shut-off system. Device testing demonstrated a nominal photovoltaic power output of 200 W. Power consumed during steady state operation was 33 W with power drawn from the combustion air blower hydronic system pump three-way switching valve and the control system resulting in a net power surplus of 142 W. Power drawn during the ignition sequence was 55 W and a battery recharge time of 1 minute 30 seconds was recorded. System efficiency was measured and found to be more than 83%. Pollutant emissions at determined operating conditions were below the South Coast Air Quality Management District’s (California) limit of 40 ng/J for NOx and carbon monoxide emissions were measured at less than 50 dppm.

Aleksandr S. Kushch; Steven M. Skinner; Richard Brennan; Pedro A. Sarmiento

1997-01-01T23:59:59.000Z

2

Small Space Heater Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Small Space Heater Basics Small Space Heater Basics Small Space Heater Basics August 19, 2013 - 10:38am Addthis Small space heaters, also called portable heaters, are typically used when the main heating system is inadequate or when central heating is too costly to install or operate. Space heater capacities generally range between 10,000 Btu to 40,000 Btu per hour. Common fuels used for this purpose are electricity, propane, natural gas, and kerosene. Although most space heaters rely on convection (the circulation of air in a room), some rely on radiant heating; that is, they emit infrared radiation that directly heats up objects and people that are within their line of sight. Combustion Space Heaters Space heaters are classified as vented and unvented, or "vent free." Unvented combustion units are not recommended for inside use, as they

3

Energy conversion by an electric “space heater”  

Science Journals Connector (OSTI)

By means of measuring the temperature of the air blown by an electric “space heater” one can show students that the air is heated at a rate approximately equal to the rated wattage of the heater.

Willem H. van den Berg

1998-01-01T23:59:59.000Z

4

Ductless Hydronic Distribution  

Broader source: Energy.gov (indexed) [DOE]

DUCTLESS HYDRONIC DUCTLESS HYDRONIC DISTRIBUTION Alliance for Residential Building Innovation David Springer, Davis Energy Group Context  Target: Builders of high performance new homes & deep retrofits  Why is this technology key to meeting performance goals of future homes?  Distribution Efficiency * Distribution efficiency for well insulated, tight ducts in attics ≈ 85% * Duct energy losses drives placement of ducts inside conditioned space, which adds cost and interferes with structure and architecture * Ductless hydronic systems can approach 100% distribution efficiency; piping needs little space  Delivery Energy * Fans: 0.58 W/cfm or 9 (heating) to 27 (cooling) W/kBtuh * Pumps: 8 W/gpm, or 0.8 W/kBtuh Context  Sizing * Conventional systems tend to be too large for low load homes

5

Optimizing Hydronic System Performance in Residential Applications  

SciTech Connect (OSTI)

Even though new homes constructed with hydronic heat comprise only 3% of the market (US Census Bureau 2009), of the 115 million existing homes in the United States, almost 14 million of those homes (11%) are heated with steam or hot water systems according to 2009 US Census data. Therefore, improvements in hydronic system performance could result in significant energy savings in the US. When operating properly, the combination of a gas-fired condensing boiler with baseboard convectors and an indirect water heater is a viable option for high-efficiency residential space heating in cold climates. Based on previous research efforts, however, it is apparent that these types of systems are typically not designed and installed to achieve maximum efficiency. Furthermore, guidance on proper design and commissioning for heating contractors and energy consultants is hard to find and is not comprehensive. Through modeling and monitoring, CARB sought to determine the optimal combination(s) of components - pumps, high efficiency heat sources, plumbing configurations and controls - that result in the highest overall efficiency for a hydronic system when baseboard convectors are used as the heat emitter. The impact of variable-speed pumps on energy use and system performance was also investigated along with the effects of various control strategies and the introduction of thermal mass.

Arena, L.; Faakye, O.

2013-10-01T23:59:59.000Z

6

Ductless Hydronic Distribution Systems  

Broader source: Energy.gov [DOE]

This presentation is from a Building America webinar conducted on November 8, 2011, by the Alliance for Residential Building Innovation (ARBI) about ductless hydronic distribution systems.

7

Space Heaters The University recognizes that individuals have different levels of comfort associated with  

E-Print Network [OSTI]

used must be currently UL (Underwriters Laboratory) approved. 4. Approved space heaters must be fan driven. Space heaters with heated coils are not permitted. 5. Space heaters must have a thermostat that shuts unit off when a certain temperature is reached. 6. Space heaters must have a tip-over shutdown

de Lijser, Peter

8

Building America Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings- Steam Systems, Retrofit Measure Packages, Hydronic Systems  

Broader source: Energy.gov [DOE]

This presentation is included in the July 16, 2014, Building America webinar, and provides information about best practices, costs, and savings associated with optimizing steam and hydronic systems through increased main line air venting, replacing radiator vents, improving circulation pump efficiency, and upgrading boiler control systems.

9

Electric Blanket vs. Space Heater: #EnergyFaceoff Round 3 Heats...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Blanket vs. Space Heater: EnergyFaceoff Round 3 Heats Up Electric Blanket vs. Space Heater: EnergyFaceoff Round 3 Heats Up November 17, 2014 - 9:49am Q&A Which appliance do you...

10

Electric Blanket Delivers K.O. to Space Heater During #EnergyFaceoff...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Electric Blanket Delivers K.O. to Space Heater During EnergyFaceoff Round Three Electric Blanket Delivers K.O. to Space Heater During EnergyFaceoff Round Three November 19, 2014...

11

Building America Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings- Control strategies to improve hydronic space heating performance  

Broader source: Energy.gov [DOE]

This webinar was presented on July 16, 2014, and provided information about improving the performance of central space conditioning systems in multifamily buildings.

12

Electric Blanket Delivers K.O. to Space Heater During #EnergyFaceoff Round Three  

Broader source: Energy.gov [DOE]

#EnergyFaceoff round three goes to the electric blanket, see how much more money it can save you over a space heater!

13

HVAC vs. Space Heaters: Which is More Efficient? | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? January 10, 2011 - 4:27pm Addthis Andrea Spikes Communicator at DOE's National Renewable Energy Laboratory I live in Colorado, and when it's cold it is very, very cold. Since I hate paying high heating bills, I typically have my thermostat set to a chilly 62°F. My husband and I have gotten used to this, and really like being able to use a warm comforter while the air stays cooler. There are some nights, however, that even this setting seems too high and the heater is running a lot more than I'd like it to. When it's below 0° overnight, or even sometimes during the day, we occasionally break out our oil-filled space heater when we're only using one room. That has me

14

HVAC vs. Space Heaters: Which is More Efficient? | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? January 10, 2011 - 4:27pm Addthis Andrea Spikes Communicator at DOE's National Renewable Energy Laboratory I live in Colorado, and when it's cold it is very, very cold. Since I hate paying high heating bills, I typically have my thermostat set to a chilly 62°F. My husband and I have gotten used to this, and really like being able to use a warm comforter while the air stays cooler. There are some nights, however, that even this setting seems too high and the heater is running a lot more than I'd like it to. When it's below 0° overnight, or even sometimes during the day, we occasionally break out our oil-filled space heater when we're only using one room. That has me

15

Ductless Hydronic Distribution Systems  

Broader source: Energy.gov (indexed) [DOE]

8, 2011 8, 2011 Ductless Hydronic Distribution Systems Welcome to the Webinar! We will start at 1:00 PM Eastern Time Be sure that you are also dialed into the telephone conference call: Dial-in number: 800-779-8694; Pass code: 2506667 Download the presentation at: www.buildingamerica.gov/meetings.html Building Technologies Program eere.energy.gov * Reduce energy use in new and existing residential buildings * Promote building science and systems engineering / integration approach * "Do no harm": Ensure safety, health and durability are maintained or improved * Accelerate adoption of high performance technologies www.buildingamerica.gov Introduction to Building America Building Technologies Program eere.energy.gov Building America Industry Consortia

16

Hydronic Radiant Cooling Systems  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

4 4 Hydronic Radiant Cooling Systems Cooling nonresidential buildings in the U.S. contributes significantly to electrical power consumption and peak power demand. Part of the electrical energy used to cool buildings is drawn by fans transporting cool air through the ducts. The typical thermal cooling peak load component for California office buildings can be divided as follows: 31% for lighting, 13% for people, 14% for air transport, and 6% for equipment (in the graph below, these account for 62.5% of the electrical peak load, labeled "chiller"). Approximately 37% of the electrical peak power is required for air transport, and the remainder is necessary to operate the compressor. DOE-2 simulations for different California climates using the California

17

Building America Whole-House Solutions for New Homes: Hydronic...  

Broader source: Energy.gov (indexed) [DOE]

Building America Whole-House Solutions for New Homes: Hydronic Heating Coil Versus Propane Furnace (Fact Sheet) Building America Whole-House Solutions for New Homes: Hydronic...

18

Building America Webinar: Ductless Hydronic Distribution Systems...  

Energy Savers [EERE]

Ductless Hydronic Distribution Systems This webinar was presented by research team Alliance for Residential Building Innovation (ARBI), and reviewed findings from a feasibility...

19

Expert Meeting Report: Recommendations for Applying Water Heaters in Combination Space and Domestic Water Heating Systems  

SciTech Connect (OSTI)

The topic of this meeting was 'Recommendations For Applying Water Heaters In Combination Space And Domestic Water Heating Systems.' Presentations and discussions centered on the design, performance, and maintenance of these combination systems, with the goal of developing foundational information toward the development of a Building America Measure Guideline on this topic. The meeting was held at the Westford Regency Hotel, in Westford, Massachusetts on 7/31/2011.

Rudd, A.; Ueno, K.; Bergey, D.; Osser, R.

2012-07-01T23:59:59.000Z

20

Impact of Ducting on Heat Pump Water Heater Space Conditioning Energy Use and Comfort  

SciTech Connect (OSTI)

Increasing penetration of heat pump water heaters (HPWHs) in the residential sector will offer an important opportunity for energy savings, with a theoretical energy savings of up to 63% per water heater and up to 11% of residential energy use (EIA 2009). However, significant barriers must be overcome before this technology will reach widespread adoption in the Pacific Northwest region and nationwide. One significant barrier noted by the Northwest Energy Efficiency Alliance (NEEA) is the possible interaction with the homes’ space conditioning system for units installed in conditioned spaces. Such complex interactions may decrease the magnitude of whole-house savings available from HPWH installed in the conditioned space in cold climates and could lead to comfort concerns (Larson et al. 2011; Kresta 2012). Modeling studies indicate that the installation location of HPWHs can significantly impact their performance and the resultant whole-house energy savings (Larson et al. 2012; Maguire et al. 2013). However, field data are not currently available to validate these results. This field evaluation of two GE GeoSpring HPWHs in the PNNL Lab Homes is designed to measure the performance and impact on the Lab Home HVAC system of a GE GeoSpring HPWH configured with exhaust ducting compared to an unducted GeoSpring HPWH during heating and cooling season periods; and measure the performance and impact on the Lab Home HVAC system of the GeoSpring HPWH with both supply and exhaust air ducting as compared to an unducted GeoSpring HPWH during heating and cooling season periods. Important metrics evaluated in these experiments include water heater energy use, HVAC energy use, whole house energy use, interior temperatures (as a proxy for thermal comfort), and cost impacts. This technical report presents results from the PNNL Lab Homes experiment.

Widder, Sarah H.; Petersen, Joseph M.; Parker, Graham B.; Baechler, Michael C.

2014-07-21T23:59:59.000Z

Note: This page contains sample records for the topic "hydronic space heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

DEVELOPMENT OF A HYDRONIC ROOFTOP UNIT -- HYPAK  

SciTech Connect (OSTI)

The majority of US commercial floor space is cooled by rooftop HVAC units (RTU's). RTU popularity derives chiefly from their low initial cost and relative ease of service access without disturbing building occupants. Unfortunately, current RTU's are inherently inefficient due to a combination of characteristics that unnecessarily increase cooling loads and energy use. Existing RTU's in the U.S. consume an estimated 2.4 quads annually. Inefficient RTU's create an estimated 3.5% of U.S. CO{sub 2} emissions, thus contributing significantly to global warming. Also, RTU's often fail to maintain adequate ventilation air and air filtration. This project was developed to evaluate the feasibility of a radically new ''HyPak'' RTU design that significantly and cost-effectively increases RTU performance and delivered air quality. The objective of the HyPak Project was to design, develop and test a hydronic RTU that provides a quantum improvement over conventional RTU performance. Our proposal targeted 60% and 50% reduction in electrical energy use by the HyPak RTU for dry and humid climates, respectively, when compared with a conventional unit.

Eric Lee; Dick Bourne; Mark Berman

2004-03-25T23:59:59.000Z

22

Conservation Division regiulations for appliance-efficiency standards relating to refrigerators and freezers, room air conditioners, central air conditioners, gas space heaters, water heaters, plumbing fittings, gas clothes dryers, and gas cooking appliances  

SciTech Connect (OSTI)

The text of the appliance efficiency standards for certain types of new appliances sold in California is presented. Specifications and test methods to identify complying refrigerators, freezers, air conditioners, gas space heaters, water heaters, plumbing fittings, gas clothes dryers, and gas cooking appliances are covered.

Not Available

1981-12-16T23:59:59.000Z

23

Expert Meeting Report: Recommendations for Applying Water Heaters in Combination Space and Domestic Water Heating Systems  

Broader source: Energy.gov (indexed) [DOE]

Recommendations for Applying Recommendations for Applying Water Heaters in Combination Space and Domestic Water Heating Systems A. Rudd, K. Ueno, D. Bergey, R. Osser Building Science Corporation June 2012 i This report received minimal editorial review at NREL. NOTICE This report was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor any agency thereof, nor any of their employees, subcontractors, or affiliated partners makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark,

24

Balancing Hydronic Systems in Multifamily Buildings  

SciTech Connect (OSTI)

In multifamily hydronic systems, temperature imbalance may be caused by undersized piping, improperly adjusted balancing valves, inefficient water temperature and flow levels, and owner/occupant interaction with the boilers, distribution and controls. The effects of imbalance include tenant discomfort, higher energy use intensity and inefficient building operation. This paper explores cost-effective distribution upgrades and balancing measures in multifamily hydronic systems, providing a resource to contractors, auditors, and building owners on best practices to improve tenant comfort and lower operating costs. The research was conducted by The Partnership for Advanced Residential Retrofit (PARR) in conjunction with Elevate Energy. The team surveyed existing knowledge on cost-effective retrofits for optimizing distribution in typical multifamily hydronic systems, with the aim of identifying common situations and solutions, and then conducted case studies on two Chicago area buildings with known balancing issues in order to quantify the extent of temperature imbalance. At one of these buildings a booster pump was installed on a loop to an underheated wing of the building. This study found that unit temperature in a multifamily hydronic building can vary as much as 61 degrees F, particularly if windows are opened or tenants use intermittent supplemental heating sources like oven ranges. Average temperature spread at the building as a result of this retrofit decreased from 22.1 degrees F to 15.5 degrees F.

Ruch, R.; Ludwig, P.; Maurer, T.

2014-07-01T23:59:59.000Z

25

Retrofit Integrated Space & Water Heating: Field Assessment, Minneapolis, Minnesota (Fact Sheet)  

SciTech Connect (OSTI)

This project analyzed combined condensing water heaters or boilers and hydronic air coils to provide high efficiency domestic hot water and forced air space heating. Called 'Combi' systems, they provided similar space and water heating performance less expensively than installing two condensing appliances. The system's installed costs were cheaper than installing a condensing furnace and either a condensing tankless or condensing storage water heater. However, combi costs must mature and be reduced before they are competitive with a condensing furnace and power vented water heater (EF of 0.60). Better insulation and tighter envelopes are reducing space heating loads for new and existing homes. For many homes, decreased space heating loads make it possible for both space and domestic water heating loads to be provided with a single heating plant. These systems can also eliminate safety issues associated with natural draft appliances through the use of one common sealed combustion vent.

Not Available

2014-05-01T23:59:59.000Z

26

Building America Expert Meeting: Recommendations for Applying Water Heaters in Combination Space and Domestic Water Heating Systems  

Broader source: Energy.gov [DOE]

The topic of this meeting was 'Recommendations For Applying Water Heaters In Combination Space And Domestic Water Heating Systems.' Presentations and discussions centered on the design, performance, and maintenance of these combination systems, with the goal of developing foundational information toward the development of a Building America Measure Guideline on this topic. The meeting was held at the Westford Regency Hotel, in Westford, Massachusetts on 7/31/2011.

27

Portable Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Portable Heaters Portable Heaters Portable Heaters November 26, 2013 - 2:41pm Addthis Portable heaters can be an efficient way to supplement inadequate heating. | Photo courtesy iStockphoto.com Portable heaters can be an efficient way to supplement inadequate heating. | Photo courtesy iStockphoto.com What does this mean for me? A portable heater is a good choice if you have a space that requires supplemental heating or is infrequently occupied. You should carefully follow all the manufacturer's installation and operation instructions. Small space heaters are typically used when the main heating system is inadequate or when central heating is too costly to install or operate. In some cases, small space heaters can be less expensive to use if you only want to heat one room or supplement inadequate heating in one room. They

28

Floating solar pool heater  

SciTech Connect (OSTI)

A floating solar heater for swimming pools is disclosed which includes a top cover, a vertical outer side wall with inclined inner side wall segments connected thereto, an outside rim and a bottom wall. The inner side wall segments are octagonal, coated with light reflective material, and aid in reflecting the sun's rays to heat the space inside the walls formed by the cover which dead air space also provides for floatation of the heater. The bottom wall is heated by direct sun inpingement and by the air in contact with it and is formed of a material having high heat conductivity.

McCluskey, J.E.

1981-08-18T23:59:59.000Z

29

Heat Pump Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Water Heaters Water Heaters Heat Pump Water Heaters May 4, 2012 - 5:21pm Addthis A diagram of a heat pump water heater. A diagram of a heat pump water heater. What does this mean for me? Heat pump water heaters can be two to three times more energy efficient than conventional electric storage water heaters. Heat pump water heaters work in locations that remain in the 40º-90ºF range year-round. Most homeowners who have heat pumps use them to heat and cool their homes. But a heat pump also can be used to heat water -- either as stand-alone water heating system, or as combination water heating and space conditioning system. How They Work Heat pump water heaters use electricity to move heat from one place to another instead of generating heat directly. Therefore, they can be two to

30

Building America Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings  

Broader source: Energy.gov [DOE]

The webinar focused on improving the performance of central space conditioning systems in multifamily buildings, including hydronic heating strategies and the evaluation of thermostatically controlled radiator valves (TRVs).

31

Hydronic Systems: Designing for Setback Operation, Ithaca, New York (Fact Sheet)  

SciTech Connect (OSTI)

Conventional wisdom surrounding space heating has told us a couple of things consistently for several years now: size the mechanical systems to the heating loads and setting the thermostat back at night will result in energy savings. The problem is these two recommendations oppose each other. A system that is properly sized to the heating load will not have the extra capacity necessary to recover from a thermostat setback, especially at design conditions. The implication of this is that, for setback to be successfully implemented, the heating system must be oversized. This issue is exacerbated further when an outdoor reset control is used with a condensing boiler, because not only is the system matched to the load at design, the outdoor reset control matches the output to the load under varying outdoor temperatures. Under these circumstances, the home may never recover from setback. Special controls to bypass the outdoor reset sensor are then needed. Properly designing a hydronic system for setback operation can be accomplished but depends on several factors. Determining the appropriateness of setback for a particular project is the first step. This is followed by proper sizing of the boiler and baseboard to ensure the needed capacity can be met. Finally, control settings must be chosen that result in the most efficient and responsive performance. This guide provides step by step instructions for heating contractors and hydronic designers for selecting the proper control settings to maximize system performance and improve response time when using a thermostat setback.

Not Available

2014-05-01T23:59:59.000Z

32

Convective heater  

DOE Patents [OSTI]

A convective heater for heating fluids such as a coal slurry is constructed of a tube circuit arrangement which obtains an optimum temperature distribution to give a relatively constant slurry film temperature. The heater is constructed to divide the heating gas flow into two equal paths and the tube circuit for the slurry is arranged to provide a mixed flow configuration whereby the slurry passes through the two heating gas paths in successive co-current, counter-current and co-current flow relative to the heating gas flow. This arrangement permits the utilization of minimum surface area for a given maximum film temperature of the slurry consistent with the prevention of coke formation.

Thorogood, Robert M. (Macungie, PA)

1983-01-01T23:59:59.000Z

33

Convective heater  

DOE Patents [OSTI]

A convective heater for heating fluids such as a coal slurry is constructed of a tube circuit arrangement which obtains an optimum temperature distribution to give a relatively constant slurry film temperature. The heater is constructed to divide the heating gas flow into two equal paths and the tube circuit for the slurry is arranged to provide a mixed flow configuration whereby the slurry passes through the two heating gas paths in successive co-current, counter-current and co-current flow relative to the heating gas flow. This arrangement permits the utilization of minimum surface area for a given maximum film temperature of the slurry consistent with the prevention of coke formation.

Thorogood, Robert M. (Macungie, PA)

1986-01-01T23:59:59.000Z

34

Field Demonstration of High Efficiency Gas Heaters  

Broader source: Energy.gov [DOE]

For many buildings that do not require space cooling, non-centralized equipment such as unit heaters provide space heating to building occupants. Unit heaters are a major source of energy use nationally, accounting for nearly 18% of primary space heating energy use for commercial buildings, and most prominently appear in warehouses, distribution centers, loading docks, etc.

35

Development of a Hydronic Rooftop Unit-HyPak-MA  

SciTech Connect (OSTI)

The majority of U.S. commercial floor space is cooled by rooftop HVAC units (RTUs). RTU popularity derives chiefly from their low initial cost and relative ease of service access without disturbing building occupants. Unfortunately, current RTUs are inherently inefficient due to a combination of characteristics that unnecessarily increase cooling loads and energy use. 36% percent of annual U.S. energy, and two-thirds of electricity, is consumed in and by buildings. Commercial buildings consume approximately 4.2 quads of energy each year at a cost of $230 billion per year, with HVAC equipment consuming 1.2 quads of electricity. More than half of all U.S. commercial floor space is cooled by packaged HVAC units, most of which are rooftop units (RTUs). Inefficient RTUs create an estimated 3.5% of U.S. CO{sub 2} emissions, thus contributing significantly to global warming5. Also, RTUs often fail to maintain adequate ventilation air and air filtration, reducing indoor air quality. This is the second HyPak project to be supported by DOE through NETL. The prior project, referred to as HyPak-1 in this report, had two rounds of prototype fabrication and testing as well as computer modeling and market research. The HyPak-1 prototypes demonstrated the high performance capabilities of the HyPak concept, but made it clear that further development was required to reduce heat exchanger cost and improve system reliability before HyPak commercialization can commence. The HyPak-1 prototypes were limited to about 25% ventilation air fraction, limiting performance and marketability. The current project is intended to develop a 'mixed-air' product that is capable of full 0-100% modulation in ventilation air fraction, hence it was referred to as HyPak-MA in the proposal. (For simplicity, the -MA has been dropped when referencing the current project.) The objective of the HyPak Project is to design, develop and test a hydronic RTU that provides a quantum improvement over conventional RTU performance. Our proposal targeted 60% and 50% reduction in electrical energy use by the HyPak RTU for dry and humid climates, respectively, when compared with a conventional unit, and reduction in peak energy consumption of 50% and 33% respectively. In addition to performance targets, our goal is to develop a production-ready design with durability, reliability and maintainability similar to air-cooled packaged equipment, and that can be commercialized immediately following the conclusion of this project.

Eric Lee; Mark Berman

2009-11-14T23:59:59.000Z

36

Sizing a New Water Heater | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Sizing a New Water Heater Sizing a New Water Heater Sizing a New Water Heater May 29, 2012 - 7:16pm Addthis Is your water heater the right size for you house? | Photo credit ENERGY STAR® Is your water heater the right size for you house? | Photo credit ENERGY STAR® A properly sized water heater will meet your household's hot water needs while operating more efficiently. Therefore, before purchasing a water heater, make sure it's the correct size. Here you'll find information about how to size these systems: Tankless or demand-type water heaters Solar water heating system Storage and heat pump (with tank) water heaters. For sizing combination water and space heating systems -- including some heat pump systems, and tankless coil and indirect water heaters -- consult a qualified contractor.

37

Tankless Coil and Indirect Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Tankless Coil and Indirect Water Heaters Tankless Coil and Indirect Water Heaters Tankless Coil and Indirect Water Heaters May 16, 2013 - 7:21pm Addthis An indirect water heater. An indirect water heater. How does it work? Tankless coil and indirect water heaters use your home's heating system to heat water. Tankless coil and indirect water heaters use a home's space heating system to heat water. They're part of what's called integrated or combination water and space heating systems. How They Work A tankless coil water heater provides hot water on demand without a tank. When a hot water faucet is turned on, water is heated as it flows through a heating coil or heat exchanger installed in a main furnace or boiler. Tankless coil water heaters are most efficient during cold months when the heating system is used regularly but can be an inefficient choice for many

38

Tankless Coil and Indirect Water Heater Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Coil and Indirect Water Heater Basics Coil and Indirect Water Heater Basics Tankless Coil and Indirect Water Heater Basics August 19, 2013 - 3:03pm Addthis Illustration of a tankless coil water heater. The heater is box-shaped, and has two pipes sticking out one end: one a cold water inlet, and one a hot water outlet. These pipes lead into the heater to a cylindrical coil called a heat exchanger. Long tubes surrounding the heat exchanger are labeled the heated water jacket. At the bottom of the box is a row of small flames, called the boiler heat source. Tankless coil and indirect water heaters use a home or building's space heating system to heat water as part of an integrated or combination water and space heating system. How Tankless Coil and Indirect Water Heaters Work A tankless coil water heater uses a heating coil or heat exchanger

39

Balancing Operation for the Optimization of Hydronic Networks  

E-Print Network [OSTI]

that the work is made and well made. ESL-IC-10/05-23 3 THE SIMULATOR Simulation model The development of the simulator for the study of hydronic networks as well as the pre-processing for hown in a previous study [4]. It is developed under Matlab/Simulink...] q Mass flow rate of water [kg/s] p ? Efficiency of the pump [-] m ? Efficiency of the engine [-] c P Pump consumptions [W] w C Average costs of electrical kWh [€/kWh] t Time of pump functioning [h] cp C Costs of pump...

Couillaud, N.; Riederer, P.; Jandon, M.; Diab, Y.

2005-01-01T23:59:59.000Z

40

Optimizing Hydronic System Performance in Residential Applications, Ithaca, New York (Fact Sheet), Building America Case Study: Technology Solutions for New and Existing Homes, Building Technologies Office (BTO)  

Broader source: Energy.gov (indexed) [DOE]

Optimizing Hydronic Optimizing Hydronic System Performance in Residential Applications Ithaca, New York PROJECT INFORMATION Project Name: Condensing Boiler Optimization Location: Ithaca, NY Partners: Ithaca Neighborhood Housing Services, www.ithacanhs.org; Appropriate Designs, www.hydronicpros.com; HTP, www.htproducts.com; Peerless, www.peerlessboilers.com; Grundfos, us.grundfos.com; Bell & Gossett, www.bell-gossett.com; Emerson Swan, www.emersonswan.com. Consortium for Advanced Residential Buildings, www.carb-swa.com Building Component: Space heating, water heating Application: New; single and multifamily Year Tested: 2012-2013 Applicable Climate Zone(s): 4,5,6,7 PERFORMANCE DATA Cost of Energy Efficiency Measure (including labor): $6,100-$8,200 Projected Energy Savings:

Note: This page contains sample records for the topic "hydronic space heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Building America Technology Solutions for New and Existing Homes:Hydronic Systems Designing for Setback Operations  

Broader source: Energy.gov [DOE]

This guide, developed by Consortium for Advanced Residential Buildings, provides step-by-step instructions for heating contractors and hydronic designers for selecting the proper control settings to maximize system performance and improve response time when using a thermostat setback.

42

Heater head for Stirling engine  

SciTech Connect (OSTI)

This patent describes a heater head for a Stirling engine comprising: a housing for enclosing the heater head with gas at a substantial elevated pressure; insulator means attached to the housing for insulating the heater head; inlet means attached to a regenerator in the housing for admission of relatively high pressure working fluid from the regenerator of a Stirling engine; a first annular heating wall in the housing attached to the inlet means for heating the working fluid; and, a second annular heating wall in the housing concentric with the first heating wall but of lesser diameters so that an annular space is formed between the first heating wall and the second heating wall for heating working fluid; and a third heating wall in the housing concentric with and smaller in diameter than the second heating wall forming the condensing area of a heat pipe between the second heating wall and the third heating wall.

White, M.A.; Emigh, S.G.

1987-06-09T23:59:59.000Z

43

Heat Pump Water Heaters  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Water Heaters Showerheads Residential Weatherization Performance Tested Comfort Systems Ductless Heat Pumps New Construction Residential Marketing Toolkit Retail Sales...

44

Selecting a new water heater  

SciTech Connect (OSTI)

This fact sheet describes the types of water heaters available (storage water heaters, demand water heaters, heat pump water heaters, tankless coil and indirect water heaters, and solar water heaters). The criteria for selection are discussed. These are capacity, efficiency rating, and cost. A resource list is provided for further information.

NONE

1995-03-01T23:59:59.000Z

45

Experimental study of slab solar collection on the hydronic system of road  

SciTech Connect (OSTI)

This paper studied the slab solar collection (SSC) process, which is one of the essential compositions of road hydronic ice-snow melting (HISM) system that stores solar energy in summer to melt ice and snow on the road in winter. Its aim is to find out the heat transfer characteristic of the SSC and heat collecting efficiency and the influence of pipe spacing and flow rate by experiment. As shown in experimental results, the average heat collecting capacity is about 150-250 W/m{sup 2} in natural summer condition, while the solar radiation intensity is about 300-1000 W/m{sup 2}. It is shown that the increment of fluid flow results in the increment of heat collection efficiency, while the increment of pipe spacing results in the decrement of the efficiency in experiment modes. The results show that the road slab can obtain about 30% solar heat in summertime, and the solar collection can lower the pavement temperature and reduce the insolation weathering. (author)

Gao, Qing; Huang, Yong; Li, Ming; Liu, Yan [Jilin University, Changchun (China); Yan, Y.Y. [University of Nottingham (United Kingdom)

2010-12-15T23:59:59.000Z

46

Tankless Water Heaters: Do They Really Work?  

Broader source: Energy.gov (indexed) [DOE]

Tankless Water Heaters: Do They Tankless Water Heaters: Do They Really Work? Center for Energy and Environment, NorthernSTAR, Ben Schoenbauer Context * Domestic Water Heating is the next big residential energy in efficiency. - Space heating loads are being reduced - Largest peak load in almost all homes is water heating - Annual water heating load is larger than annual space heating load in many homes - Most DHW equipment is inefficiency 50-60% Technical Approach * TWHs and condensing TWHs have significant energy savings potential - Do these ratings relate to real world performance? - How do TWHs compare to standard water heaters? - What performance/install issues do they have? * 10 home 26 water heater alternating mode field study was conducted Recommended Guidance * In situations where economics are

47

Swimming Pool Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Energy Efficiency Homes Water Heating Swimming Pool Heaters Swimming Pool Heaters July 10, 2014 Gas Swimming Pool Heaters Selecting the right kind of swimming pool heater...

48

Grouped exposed metal heaters  

DOE Patents [OSTI]

A system for treating a hydrocarbon containing formation is described. The system includes two or more groups of elongated heaters. The group includes two or more heaters placed in two or more openings in the formation. The heaters in the group are electrically coupled below the surface of the formation. The openings include at least partially uncased wellbores in a hydrocarbon layer of the formation. The groups are electrically configured such that current flow through the formation between at least two groups is inhibited. The heaters are configured to provide heat to the formation.

Vinegar, Harold J. (Bellaire, TX); Coit, William George (Bellaire, TX); Griffin, Peter Terry (Brixham, GB); Hamilton, Paul Taylor (Houston, TX); Hsu, Chia-Fu (Granada Hills, CA); Mason, Stanley Leroy (Allen, TX); Samuel, Allan James (Kular Lumpar, MY); Watkins, Ronnie Wade (Cypress, TX)

2010-11-09T23:59:59.000Z

49

Building America Expert Meeting Final Report: Multifamily Hydronic and Steam Heating Controls and Distribution Retrofits  

Broader source: Energy.gov (indexed) [DOE]

Hydronic Hydronic Heating in Multifamily Buildings Jordan Dentz The ARIES Collaborative October 2011 NOTICE This report was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation,

50

Building America Case Study: Balancing Hydronic Systems in Multifamily Buildings, Chicago, Illinois (Fact Sheet)  

SciTech Connect (OSTI)

In multifamily hydronic systems, temperature imbalance may be caused by undersized piping, improperly adjusted balancing valves, inefficient water temperature and flow levels, and owner/occupant interaction with the boilers, distribution and controls. The effects of imbalance include tenant discomfort, higher energy use intensity and inefficient building operation. This paper explores cost-effective distribution upgrades and balancing measures in multifamily hydronic systems, providing a resource to contractors, auditors, and building owners on best practices to improve tenant comfort and lower operating costs. The research was conducted by The Partnership for Advanced Residential Retrofit (PARR) in conjunction with Elevate Energy. The team surveyed existing knowledge on cost-effective retrofits for optimizing distribution in typical multifamily hydronic systems, with the aim of identifying common situations and solutions, and then conducted case studies on two Chicago area buildings with known balancing issues in order to quantify the extent of temperature imbalance. At one of these buildings a booster pump was installed on a loop to an underheated wing of the building. This study found that unit temperature in a multifamily hydronic building can vary as much as 61 degrees F, particularly if windows are opened or tenants use intermittent supplemental heating sources like oven ranges. Average temperature spread at the building as a result of this retrofit decreased from 22.1 degrees F to 15.5 degrees F.

Not Available

2014-09-01T23:59:59.000Z

51

Building America Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings  

Broader source: Energy.gov [DOE]

This webinar will focus on improving the performance of central space conditioning systems in multifamily buildings. Presenters will discuss hydronic heating strategies and the evaluation of thermostatically controlled radiator valves (TRVs).

52

Explosives tester with heater  

DOE Patents [OSTI]

An inspection tester system for testing for explosives. The tester includes a body and a swab unit adapted to be removeably connected to the body. At least one reagent holder and dispenser is operatively connected to the body. The reagent holder and dispenser contains an explosives detecting reagent and is positioned to deliver the explosives detecting reagent to the swab unit. A heater is operatively connected to the body and the swab unit is adapted to be operatively connected to the heater.

Del Eckels, Joel (Livermore, CA); Nunes, Peter J. (Danville, CA); Simpson, Randall L. (Livermore, CA); Whipple, Richard E. (Livermore, CA); Carter, J. Chance (Livermore, CA); Reynolds, John G. (San Ramon, CA)

2010-08-10T23:59:59.000Z

53

Building America Technology Solutions for New and Existing Homes: Optimizing Hydronic System Performance in Residential Applications (Fact Sheet)  

Broader source: Energy.gov [DOE]

In this project, researchers from the Consortium for Advanced Residential Buildings team worked with industry partners to develop hydronic system designs that would address performance issues and result in higher overall system efficiencies and improved response times.

54

Building America Technology Solutions for New and Existing Homes: Boiler Control Replacement for Hydronically Heated Multifamily Buildings, Cambridge, Massachusetts  

Broader source: Energy.gov [DOE]

The ARIES Collaborative partnered with Homeowners' Rehab Inc., a nonprofit affordable housing owner, to upgrade the central hydronic heating system in a 42-unit housing development, reducing heating energy use by an average of 19%.

55

Department of Energy - Swimming Pool Heaters  

Broader source: Energy.gov (indexed) [DOE]

736189 en Gas Swimming Pool Heaters http:energy.govenergysaverarticlesgas-swimming-pool-heaters heaters" class"title-link">

56

Combined Systems with Tankless Water Heaters  

Broader source: Energy.gov (indexed) [DOE]

Combined Systems with Tankless Water Heaters Combined Systems with Tankless Water Heaters Armin Rudd Residential Energy Efficiency Stakeholder Meeting 2/29 - 3/2/2012 Austin, Texas 2 Residential Energy Efficiency Stakeholder Meeting 2/29 - 3/2/2012 Austin, Texas More builder's wanting to use gas-fired tankless water heaters, and with solar pre-heat  Endless hot water  Helps HERS Index  Space saving 2 3 Residential Energy Efficiency Stakeholder Meeting 2/29 - 3/2/2012 Austin, Texas Problem with elevated TWH inlet temperature 60 70 80 90 100 110 120 130 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 Maximum Inlet Temperature (F) DHW flow rate (gpm) Maximum TWH inlet temperature to stay below 125 F delivered temperature, with 15 kBtu/h minimum firing rate Typical shower temperature 4 Residential Energy Efficiency Stakeholder Meeting

57

Hydronic Heating Retrofits for Low-Rise Multifamily Buildings: Boiler Control Replacement and Monitoring  

SciTech Connect (OSTI)

The ARIES Collaborative, a U.S. Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. of Cambridge, Massachusetts, to implement and study improvements to the central hydronic heating system in one of the nonprofit's housing developments. The heating control systems in the three-building, 42-unit Columbia Cambridge Alliance for Spanish Tenants housing development were upgraded.

Dentz, J.; Henderson, H.; Varshney, K.

2013-10-01T23:59:59.000Z

58

Energy Conservation in Process Heaters  

E-Print Network [OSTI]

ENERGY CONSERVATION IN PROCESS HEATERS Roger l~. Bagge Neste Engineering Porvoo, Finland ABSTRACT OPTIMIZATION OF EMER~Y USE Energy savings in refinery and petrochemical fired heaters can basically be achieved in two ways: Thru optimization...

Bagge, R. W.

1982-01-01T23:59:59.000Z

59

Absorption Heat Pump Water Heater  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Absorption Heat Pump Water Heater Absorption Heat Pump Water Heater Kyle Gluesenkamp Building Equipment Group, ETSD gluesenkampk@ornl.gov 865-241-2952 April 3, 2013 CRADA - GE Development of High Performance Residential Gas Water Heater Image courtesy John Wilkes 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: Absorption technology could greatly boost water heater efficiency, but faces barriers of high first cost and working fluid challenges. Impact of Project: Energy factor of gas storage water

60

Absorption Heat Pump Water Heater  

Broader source: Energy.gov (indexed) [DOE]

Absorption Heat Pump Water Heater Absorption Heat Pump Water Heater Kyle Gluesenkamp Building Equipment Group, ETSD gluesenkampk@ornl.gov 865-241-2952 April 3, 2013 CRADA - GE Development of High Performance Residential Gas Water Heater Image courtesy John Wilkes 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: Absorption technology could greatly boost water heater efficiency, but faces barriers of high first cost and working fluid challenges. Impact of Project: Energy factor of gas storage water

Note: This page contains sample records for the topic "hydronic space heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Dehumidifying water heater  

SciTech Connect (OSTI)

The indoor swimming pool at the Glen Cove YMCA in Glen Cove, New York, has been selected for the dehumidification/water heating system demonstration project. This report provides the specifications for this system which includes a dehumidifier/air handler, condenser/water heater, and outdoor condenser. Current progress underway includes construction, vendor selection, and control system selection. (SM)

Stark, W.

1991-05-31T23:59:59.000Z

62

Immersible solar heater for fluids  

DOE Patents [OSTI]

An immersible solar heater comprising a light-absorbing panel attached to a frame for absorbing heat energy from the light and transferring the absorbed heat energy directly to the fluid in which the heater is immersed. The heater can be used to heat a swimming pool, for example, and is held in position and at a preselected angle by a system of floats, weights and tethers so that the panel can operate efficiently. A skid can be used in one embodiment to prevent lateral movement of the heater along the bottom of the pool. Alternative embodiments include different arrangements of the weights, floats and tethers and methods for making the heater.

Kronberg, James W. (Aiken, SC)

1995-01-01T23:59:59.000Z

63

Do You Have a Solar Water Heater?  

Broader source: Energy.gov [DOE]

Earlier this week, Ernie wrote about the economics of getting a solar water heater. As Ernie explained, a solar water heater is more expensive than a normal water heater, but depending on your area...

64

Tankless water heaters fill the bill at fast-food restaurants  

SciTech Connect (OSTI)

This article explains why Kentucky Fried Chicken has installed a PH-24 water heater. The tankless water heater meets the restaurant's criteria for space spacing, flow rates, certification and availability, and money saving efficiency. This article describes the system and its advantages.

Not Available

1988-02-01T23:59:59.000Z

65

Building America Technology Solutions for New and Existing Homes: Balancing Hydronic Systems in Multifamily Buildings, Chicago, Illinois (Fact Sheet)  

Broader source: Energy.gov [DOE]

In this case study , Partnership for Advanced Residential Retrofit and Elevate Energy. explores cost-effective distribution upgrades and balancing measures in multifamily hydronic systems, providing a resource to contractors, auditors, and building owners on best practices to improve tenant comfort and lower operating costs.

66

Immersible solar heater for fluids  

DOE Patents [OSTI]

An immersible solar heater is described comprising a light-absorbing panel attached to a frame for absorbing heat energy from the light and transferring the absorbed heat energy directly to the fluid in which the heater is immersed. The heater can be used to heat a swimming pool, for example, and is held in position and at a preselected angle by a system of floats, weights and tethers so that the panel can operate efficiently. A skid can be used in one embodiment to prevent lateral movement of the heater along the bottom of the pool. Alternative embodiments include different arrangements of the weights, floats and tethers and methods for making the heater.

Hazen, T.C.; Fliermans, C.B.

1994-01-01T23:59:59.000Z

67

Immersible solar heater for fluids  

DOE Patents [OSTI]

An immersible solar heater is described comprising a light-absorbing panel attached to a frame for absorbing heat energy from the light and transferring the absorbed heat energy directly to the fluid in which the heater is immersed. The heater can be used to heat a swimming pool, for example, and is held in position and at a preselected angle by a system of floats, weights and tethers so that the panel can operate efficiently. A skid can be used in one embodiment to prevent lateral movement of the heater along the bottom of the pool. Alternative embodiments include different arrangements of the weights, floats and tethers and methods for making the heater. 11 figs.

Kronberg, J.W.

1995-07-11T23:59:59.000Z

68

The Impact of Blowing Agents on Residential Water Heater Performance  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

The Impact of Blowing Agents on Residential Water Heater Performance The Impact of Blowing Agents on Residential Water Heater Performance Title The Impact of Blowing Agents on Residential Water Heater Performance Publication Type Report LBNL Report Number LBNL-47352 Year of Publication 2001 Authors Lekov, Alexander B., James D. Lutz, Camilla Dunham Whitehead, and James E. McMahon Document Number LBNL-47352 Date Published January 12 Abstract The National Appliance Energy Conservation Act of 1987 (NAECA) requires the U.S. Department of Energy (DOE) to consider amendments to the energy conservation standards to increase energy efficiency in residential water heaters. A driving force affecting efficiency is the ozone-depletion regulation regarding blowing agents for insulation in all water heater fuel types. This paper presents results of cost and efficiency impacts of three potential blowing agents. Residential water heaters are typically insulated with polyurethane foam in the space between the tank and the jacket. Currently, water heater manufacturers use HCFC-141b, an ozone-depleting substance, as a blowing agent. After 2003, as a result of the Montreal Protocol (1993), manufacturers must use blowing agents that do not deplete the ozone layer. The analysis presented in this paper considers three replacement candidates, HFC-245fa, HFC-134a, and cyclopentane by comparing their efficiency and cost effectiveness when applied to water heater insulation. This analysis used computer simulation models and other analytical methods to investigate the efficiency improvements due to different design options, when alternative blowing agents are applied. The calculations were based on the DOE test procedure for residential water heaters. The analysis used average manufacturer, retailer, and installer costs to calculate the total consumer costs. Consumer operating expenses were calculated based on modeled energy consumption under test procedure conditions and U.S. average energy prices. With this information, a cost-efficiency relationship was developed to show the average manufacturer and consumer cost to achieve increased efficiency.

69

Advanced Hybrid Water Heater using Electrochemical Compressor...  

Energy Savers [EERE]

Advanced Hybrid Water Heater using Electrochemical Compressor Advanced Hybrid Water Heater using Electrochemical Compressor Xergy is using its Electro Chemical Compression (ECC)...

70

Tankless Gas Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Tankless Gas Water Heaters Tankless Gas Water Heaters Standardized Templates for Reporting Test Results tanklessgaswaterheaterv12.xlsx More Documents & Publications Heat Pump...

71

Commercial Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Water Heaters Commercial Water Heaters Standardized DOE Testing Templates commercialwaterheater v1.0.xlsx More Documents & Publications Refrigerators and Refrigerator-Freezers...

72

Storage Gas Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Storage Gas Water Heaters Storage Gas Water Heaters The Department of Energy (DOE) develops standardized data templates for reporting the results of tests conducted in accordance...

73

Heat Pump Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Heat Pump Water Heaters Heat Pump Water Heaters Standardized Templates for Reporting Test Results heatpumpwaterheaterv1.7.xlsx More Documents & Publications Tankless Gas Water...

74

FS: heat pump water heaters | The Better Buildings Alliance  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Food Service » Install a heat pump Food Service » Install a heat pump water heaterand reduce water heating energy up to 70% using the commercial heat pump water heater specificat Activities Technology Solutions Teams Lighting & Electrical Space Conditioning Plug & Process Loads Food Service Refrigeration Laboratories Energy Management & Information Systems Public Sector Teams Market Solutions Teams Install a heat pump water heaterand reduce water heating energy up to 70% using the commercial heat pump water heater specification The Food Service team developed a Commercial Heat Pump Water Heater Specification that can be used to reduce water heating energy by 70%. An older, electric resistance water heater (operated in a building with a hot water demand of 500 gallons a day) can cost more than $3,500 each year

75

Building America Technology Solutions for New and Existing Homes: Optimizing Hydronic System Performance in Residential Applications, Ithaca, New York (Fact Sheet)  

Broader source: Energy.gov [DOE]

In this project, researchers from Building America team Consortium for Advanced Residential Buildings worked with industry partners to develop hydronic system designs that would address barriers and result in higher overall system efficiencies and improved response times.

76

Methods for forming long subsurface heaters  

DOE Patents [OSTI]

A method for forming a longitudinal subsurface heater includes longitudinally welding an electrically conductive sheath of an insulated conductor heater along at least one longitudinal strip of metal. The longitudinal strip is formed into a tubular around the insulated conductor heater with the insulated conductor heater welded along the inside surface of the tubular.

Kim, Dong Sub

2013-09-17T23:59:59.000Z

77

Heater head for stirling engine  

DOE Patents [OSTI]

A monolithic heater head assembly which augments cast fins with ceramic inserts which narrow the flow of combustion gas and obtains high thermal effectiveness with the assembly including an improved flange design which gives greater durability and reduced conduction loss.

Corey, John A. (R.D. #2, Box 101 E, North Troy, NY 12182)

1985-07-09T23:59:59.000Z

78

Hydronic Controls Retrofits for Low-Rise Multi-Famiy Buildings  

Broader source: Energy.gov (indexed) [DOE]

Residential Integrated Energy Solutions Residential Integrated Energy Solutions Building America Stakeholder Meeting Austin, Texas February 29 to March 2, 2012 Hugh Henderson, CDH Energy Corp. Jordan Dentz, The Levy Partnership, Inc. Hydronic Controls Retrofits for Low-Rise Multi-Family Buildings Research Objective * Determine the impact of control strategies that use apartment temperatures for central boiler control on energy consumption, comfort and cost. * Compare energy performance, comfort and cost to individual radiator valve controls in each apartment. Background * Most multi-family boiler systems have: - No zone/apartment level control, or - Non-electric thermostats on radiator valves * Central boiler system resets hot water based on outdoor temperature * Problem: - apartments are often too hot or too cold.

79

Tankless Gas Water Heater Performance - Building America Top...  

Energy Savers [EERE]

Tankless Gas Water Heater Performance - Building America Top Innovation Tankless Gas Water Heater Performance - Building America Top Innovation This photo shows a hot water heater...

80

Heat Pump Water Heaters and American Homes: A Good Fit?  

E-Print Network [OSTI]

M.V. Lapsa. 2001. Residential Heat Pump Water Heater (HPWH)Calwell. 2005. Residential Heat Pump Water Heaters: Energyfor Residential Heat Pump Water Heaters Installed in

Franco, Victor

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hydronic space heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Heat Pump Water Heaters and American Homes: A Good Fit?  

E-Print Network [OSTI]

2001. Residential Heat Pump Water Heater (HPWH) Development2005. Residential Heat Pump Water Heaters: Energy Efficiencyfor Residential Heat Pump Water Heaters Installed in

Franco, Victor

2011-01-01T23:59:59.000Z

82

A performance correlation of horizontal solar heaters  

E-Print Network [OSTI]

The solar heaters are shown tn Figure VI, page 31 30 Figure VI Horizontal Solar Heaters ~GLAZING AND FRAME ~~ POLYETHYLENE HEATERS THERMAL IN S U LA T I N 8 CELLS THERMOCOUPLES HORIZONTAL TABLE TOP THERMOCOUPLES COPPER LEADS TO CONTROL... The solar heaters are shown tn Figure VI, page 31 30 Figure VI Horizontal Solar Heaters ~GLAZING AND FRAME ~~ POLYETHYLENE HEATERS THERMAL IN S U LA T I N 8 CELLS THERMOCOUPLES HORIZONTAL TABLE TOP THERMOCOUPLES COPPER LEADS TO CONTROL...

Gopffarth, Wilford Hugo

2012-06-07T23:59:59.000Z

83

Applications Tests of Commercial Heat Pump Water Heaters  

E-Print Network [OSTI]

Field application tests have been conducted on three 4 to 6-ton commercial heat pump water heater systems in a restaurant, a coin-operated laundry, and an office building cafeteria in Atlanta. The units provide space cooling while rejecting heat...

Oshinski, J. N..; Abrams, D. W.

1987-01-01T23:59:59.000Z

84

Solar heater for swimming pools  

SciTech Connect (OSTI)

A solar heater for swimming pools is provided having one or more heating panels installable on a roof or the like and arranged to discharge into a pool equipped with an apron without need for disturbing or obstructing the apron. This is accomplished by the provision of an elevated bistable dumper adjacent the perimeter of the apron having a dispensing spout normally inclined upwardly but pivoting at intervals to discharge into the pool across the apron without obstructing it. Water to be heated is diverted from the pool filtering system to the solar heater via a pressure regulator and a solar responsive flow control.

Babcock, H.W.

1984-12-04T23:59:59.000Z

85

Storage Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Storage Water Heaters Storage Water Heaters Storage Water Heaters June 15, 2012 - 6:00pm Addthis Consider energy efficiency when selecting a conventional storage water heater to avoid paying more over its lifetime. | Photo courtesy of ©iStockphoto/JulNichols. Consider energy efficiency when selecting a conventional storage water heater to avoid paying more over its lifetime. | Photo courtesy of ©iStockphoto/JulNichols. Conventional storage water heaters remain the most popular type of water heating system for the home. Here you'll find basic information about how storage water heaters work; what criteria to use when selecting the right model; and some installation, maintenance, and safety tips. How They Work A single-family storage water heater offers a ready reservoir -- from 20 to

86

An internal winding high temperature heater  

Science Journals Connector (OSTI)

An internal winding high temperature heater ... General principles are outlined for the construction of compact heaters that are suitable for heating small containers or reaction vessels at constant temperature and up to about 1000 C. ...

A. J. Delbouille; E. G. Derouane

1973-01-01T23:59:59.000Z

87

CO2 Heat Pump Water Heater | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Heater CO2 Heat Pump Water Heater CO2 Heat Pump Water Heater Prototype
Credit: Oak Ridge National Lab CO2 Heat Pump Water Heater Prototype Credit: Oak Ridge National Lab...

88

Oil and Gas Air Heaters  

E-Print Network [OSTI]

ICEBO2006, Shenzhen, China Heating technologies for energy efficiency Vol.III-1-2 Oil and Gas Air Heaters1 Guangxiao Kou Hanqing Wang Jiemin Zhou Doctoral Ph.D Ph.D Candidate Professor Professor Hunan University of Technology Hunan...

Kou, G.; Wang, H.; Zhou, J.

2006-01-01T23:59:59.000Z

89

Applications of Commercial Heat Pump Water Heaters in Hot, Humid Climates  

E-Print Network [OSTI]

Heat pump water heaters can provide high-efficiency water heating and supplemental space cooling and dehumidification in commercial buildings throughout the United States. They are particularly attractive in hot, humid areas where cooling loads...

Johnson, K. F.; Shedd, A. C.

90

Hydronic Heating Retrofits for Low-Rise Multifamily Buildings: Boiler Control Replacement and Monitoring  

SciTech Connect (OSTI)

The ARIES Collaborative, a U.S. Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. (HRI) of Cambridge, Massachusetts, to study improvements to the central hydronic heating system in one of the nonprofit's housing developments. The heating controls in the three-building, 42-unit Columbia Cambridge Alliance for Spanish Tenants housing development were upgraded. Fuel use in the development was excessive compared to similar properties. A poorly insulated thermal envelope contributed to high energy bills, but adding wall insulation was not cost-effective or practical. The more cost-effective option was improving heating system efficiency. Efficient operation of the heating system faced several obstacles, including inflexible boiler controls and failed thermostatic radiator valves. Boiler controls were replaced with systems that offer temperature setbacks and one that controls heat based on apartment temperature in addition to outdoor temperature. Utility bill analysis shows that post-retrofit weather-normalized heating energy use was reduced by 10%-31% (average of 19%). Indoor temperature cutoff reduced boiler runtime (and therefore heating fuel consumption) by 28% in the one building in which it was implemented. Nearly all savings were obtained during night which had a lower indoor temperature cut off (68 degrees F) than day (73 degrees F). This implies that the outdoor reset curve was appropriately adjusted for this building for daytime operation. Nighttime setback of heating system supply water temperature had no discernable impact on boiler runtime or gas bills.

Dentz, J.; Henderson, H.; Varshney, K.

2014-09-01T23:59:59.000Z

91

Building America Case Study: Boiler Control Replacement for Hydronically Heated Multifamily Buildings, Cambridge, Massachusetts (Fact Sheet)  

SciTech Connect (OSTI)

The ARIES Collaborative, a U.S. Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. (HRI) of Cambridge, Massachusetts, to study improvements to the central hydronic heating system in one of the nonprofit's housing developments. The heating controls in the three-building, 42-unit Columbia Cambridge Alliance for Spanish Tenants housing development were upgraded. Fuel use in the development was excessive compared to similar properties. A poorly insulated thermal envelope contributed to high energy bills, but adding wall insulation was not cost-effective or practical. The more cost-effective option was improving heating system efficiency. Efficient operation of the heating system faced several obstacles, including inflexible boiler controls and failed thermostatic radiator valves. Boiler controls were replaced with systems that offer temperature setbacks and one that controls heat based on apartment temperature in addition to outdoor temperature. Utility bill analysis shows that post-retrofit weather-normalized heating energy use was reduced by 10%-31% (average of 19%). Indoor temperature cutoff reduced boiler runtime (and therefore heating fuel consumption) by 28% in the one building in which it was implemented. Nearly all savings were obtained during night which had a lower indoor temperature cut off (68 degrees F) than day (73 degrees F). This implies that the outdoor reset curve was appropriately adjusted for this building for daytime operation. Nighttime setback of heating system supply water temperature had no discernable impact on boiler runtime or gas bills.

Not Available

2014-11-01T23:59:59.000Z

92

Solar Swimming Pool Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Swimming Pool Heaters Swimming Pool Heaters Solar Swimming Pool Heaters May 29, 2012 - 6:03pm Addthis An example of a solar pool heater. An example of a solar pool heater. You can significantly reduce swimming pool heating costs by installing a solar pool heater. They're cost competitive with both gas and heat pump pool heaters, and they have very low annual operating costs. Actually, solar pool heating is the most cost-effective use of solar energy in many climates. How They Work Most solar pool heating systems include the following: A solar collector -- the device through which pool water is circulated to be heated by the sun A filter -- removes debris before water is pumped through the collector A pump -- circulates water through the filter and collector and back to the pool A flow control valve -- automatic or manual device that diverts pool

93

Solar Water Heater Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Solar Water Heater Basics Solar Water Heater Basics Solar Water Heater Basics August 19, 2013 - 3:01pm Addthis Illustration of an active, closed loop solar water heater. A large, flat panel called a flat plate collector is connected to a tank called a solar storage/backup water heater by two pipes. One of these pipes runs through a cylindrical pump into the bottom of the tank, where it becomes a coil called a double-wall heat exchanger. This coil runs up through the tank and out again to the flat plate collector. Antifreeze fluid runs only through this collector loop. Two pipes run out the top of the water heater tank; one is a cold water supply into the tank, and the other sends hot water to the house. Solar water heaters use the sun's heat to provide hot water for a home or

94

Solar Swimming Pool Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Solar Swimming Pool Heaters Solar Swimming Pool Heaters Solar Swimming Pool Heaters May 29, 2012 - 6:03pm Addthis An example of a solar pool heater. An example of a solar pool heater. You can significantly reduce swimming pool heating costs by installing a solar pool heater. They're cost competitive with both gas and heat pump pool heaters, and they have very low annual operating costs. Actually, solar pool heating is the most cost-effective use of solar energy in many climates. How They Work Most solar pool heating systems include the following: A solar collector -- the device through which pool water is circulated to be heated by the sun A filter -- removes debris before water is pumped through the collector A pump -- circulates water through the filter and collector and back to the pool

95

Welding shield for coupling heaters  

DOE Patents [OSTI]

Systems for coupling end portions of two elongated heater portions and methods of using such systems to treat a subsurface formation are described herein. A system may include a holding system configured to hold end portions of the two elongated heater portions so that the end portions are abutted together or located near each other; a shield for enclosing the end portions, and one or more inert gas inlets configured to provide at least one inert gas to flush the system with inert gas during welding of the end portions. The shield may be configured to inhibit oxidation during welding that joins the end portions together. The shield may include a hinged door that, when closed, is configured to at least partially isolate the interior of the shield from the atmosphere. The hinged door, when open, is configured to allow access to the interior of the shield.

Menotti, James Louis (Dickinson, TX)

2010-03-09T23:59:59.000Z

96

Regenerative Boiler Feedwater Heater Economics  

E-Print Network [OSTI]

REGENERATIVE BOILER FEEDWATER HEATER ECONOMICS William L. Viar, PE waterland, Viar & Associates, Inc. Wilmington, Delaware ABSTRACT The basic Rankine Vapor Cycle has been r,~peatedly modified to improve efficiency. Always, the objective....g., first and second laws of thermodynamics) have improved and contributed to the evolution. The demands for larger systems with higher performance have been persistent. Progress i ve changes in the app1icat ion of the fundamental Rankine cycle have...

Viar, W. L.

97

Performance improvement of direct- and indirect-fired heaters  

SciTech Connect (OSTI)

The operating performance of direct and indirect heaters is discussed, and principles and guidelines that can be applied to effect improvements in efficiency are presented. This paper also discusses the associated heater efficiencies and several useful operating techniques to approach the maximum, steady-state heater efficiency. The techniques presented apply to all types of direct-and indirect-fired heaters: salt bath heaters, propane vaporizers, heater/treaters, production heaters, and glycol and amine regenerators.

Sams, G.W.; Hunter, J.D.

1988-08-01T23:59:59.000Z

98

Adjusting alloy compositions for selected properties in temperature limited heaters  

DOE Patents [OSTI]

Heaters for treating a subsurface formation are described herein. Such heaters can be obtained by using the systems and methods described herein. The heater includes a heater section including iron, cobalt, and carbon. The heater section has a Curie temperature less than a phase transformation temperature. The Curie temperature is at least 740.degree. C. The heater section provides, when time varying current is applied to the heater section, an electrical resistance.

Brady; Michael Patrick (Oak Ridge, TN), Horton, Jr.; Joseph Arno (Oak Ridge, TN), Vitek; John Michael (Oak Ridge, TN)

2010-03-23T23:59:59.000Z

99

Comparative performance evaluation of cascaded air-source hydronic heat pumps  

Science Journals Connector (OSTI)

Abstract The results are reported of an investigation of the effects of cascading air-source heat pumps on performance for hydronic residential systems. Three heat pump systems are modeled as single-stage, single-refrigerant cascaded, and two-refrigerant cascaded. Energy and exergy analyses are performed, and a comparative performance analysis is carried out, considering energy efficiency, refrigerant mass flow rates, evaporator pressure, exergy efficiency, and several other criteria. Three sets of source and supply temperatures, representing different climates and different water sink systems (low, medium and high temperature), are used to provide more comprehensive behavior assessments of the systems. Additionally, the optimum intermediate pressure of the cascaded systems for all working temperature pairs is found for the highest energetic COP and exergetic COP. Compared to a single stage heat pump, cascading improves the overall energy efficiency of the system for low-ambient temperatures, but not for high-ambient temperatures. Although this improvement is minor, the exergetic COP is increased by 67% for the single refrigerant cascaded system and 70% for a two-refrigerant cascaded system, at low ambient temperatures. Using refrigerant R404A in the low-pressure cycle marginally improves the energetic COP of the cascaded heat pump, but increases the evaporator working pressure, making it possible to use smaller compressors. However, the overall refrigerant mass flow rates increase with cascading. The two cascaded systems have higher exergy destructions (by almost four times) compared to the single stage system, mainly due to having more components, including an intermediate heat exchanger. Also, cascading shifts the major exergy destruction centers from the compressors and expansion valves to the evaporators. A comparison of cascaded and single-stage heat pumps shows that the exergy analysis results exhibit a different trend than energy analysis results with source and supply temperatures, highlighting the advantages of exergy methods in determining if cascading is appropriate for a given application.

R. Soltani; I. Dincer; M.A. Rosen

2015-01-01T23:59:59.000Z

100

Critical Question #8: When are Heat Pump Water Heaters the Best Solution? |  

Broader source: Energy.gov (indexed) [DOE]

8: When are Heat Pump Water Heaters the Best 8: When are Heat Pump Water Heaters the Best Solution? Critical Question #8: When are Heat Pump Water Heaters the Best Solution? What do we know about actual performance compared to promised performance? What is the best way to manage the space conditioning impacts on a home? Is there an easy decision tree for deciding if this is the best solution for a particular home (Climate? Utility prices? Accessibility? Physical space constraints? Workforce?)? cq8_residential_hpwh_costs_maguire.pdf cq8_hpwh_performance_colon.pdf cq8_hpwhs_multifamily_weitzel.pdf More Documents & Publications Track A - Energy Systems Innovations Illustrative Calculation of Economics for Heat Pump and "Grid-Enabled" Water Heaters Standing Technical Committee Working Sessions

Note: This page contains sample records for the topic "hydronic space heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

CO2 Conversion By Nano Heaters  

SciTech Connect (OSTI)

A graduate student named Oshadha Ranasingha created this animation on the research he performed on nano heaters while working at NETL.

None

2014-03-11T23:59:59.000Z

102

CO2 Heat Pump Water Heater  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

CO 2 Heat Pump Water Heater 2014 Building Technologies Office Peer Review Evaporator Kyle Gluesenkamp, gluesenkampk@ornl.gov Oak Ridge National Laboratory Project Summary Timeline:...

103

CO2 Conversion By Nano Heaters  

ScienceCinema (OSTI)

A graduate student named Oshadha Ranasingha created this animation on the research he performed on nano heaters while working at NETL.

None

2014-06-23T23:59:59.000Z

104

Parallel heater system for subsurface formations  

DOE Patents [OSTI]

A heating system for a subsurface formation is disclosed. The system includes a plurality of substantially horizontally oriented or inclined heater sections located in a hydrocarbon containing layer in the formation. At least a portion of two of the heater sections are substantially parallel to each other. The ends of at least two of the heater sections in the layer are electrically coupled to a substantially horizontal, or inclined, electrical conductor oriented substantially perpendicular to the ends of the at least two heater sections.

Harris, Christopher Kelvin (Houston, TX); Karanikas, John Michael (Houston, TX); Nguyen, Scott Vinh (Houston, TX)

2011-10-25T23:59:59.000Z

105

Combustion heater for oil shale  

DOE Patents [OSTI]

A combustion heater for oil shale heats particles of spent oil shale containing unburned char by burning the char. A delayed fall is produced by flowing the shale particles down through a stack of downwardly sloped overlapping baffles alternately extending from opposite sides of a vertical column. The delayed fall and flow reversal occurring in passing from each baffle to the next increase the residence time and increase the contact of the oil shale particles with combustion supporting gas flowed across the column to heat the shale to about 650 to 700/sup 0/C for use as a process heat source.

Mallon, R.; Walton, O.; Lewis, A.E.; Braun, R.

1983-09-21T23:59:59.000Z

106

Combustion heater for oil shale  

DOE Patents [OSTI]

A combustion heater for oil shale heats particles of spent oil shale containing unburned char by burning the char. A delayed fall is produced by flowing the shale particles down through a stack of downwardly sloped overlapping baffles alternately extending from opposite sides of a vertical column. The delayed fall and flow reversal occurring in passing from each baffle to the next increase the residence time and increase the contact of the oil shale particles with combustion supporting gas flowed across the column to heat the shale to about 650.degree.-700.degree. C. for use as a process heat source.

Mallon, Richard G. (Livermore, CA); Walton, Otis R. (Livermore, CA); Lewis, Arthur E. (Los Altos, CA); Braun, Robert L. (Livermore, CA)

1985-01-01T23:59:59.000Z

107

Economics of residential gas furnaces and water heaters in United States new construction market  

SciTech Connect (OSTI)

New single-family home construction represents a significant and important market for the introduction of energy-efficient gas-fired space heating and water-heating equipment. In the new construction market, the choice of furnace and water-heater type is primarily driven by first cost considerations and the availability of power vent and condensing water heaters. Few analysis have been performed to assess the economic impacts of the different combinations of space and water-heating equipment. Thus, equipment is often installed without taking into consideration the potential economic and energy savings of installing space and water-heating equipment combinations. In this study, we use a life-cycle cost analysis that accounts for uncertainty and variability of the analysis inputs to assess the economic benefits of gas furnace and water-heater design combinations. This study accounts not only for the equipment cost but also for the cost of installing, maintaining, repairing, and operating the equipment over its lifetime. Overall, this study, which is focused on US single-family new construction households that install gas furnaces and storage water heaters, finds that installing a condensing or power-vent water heater together with condensing furnace is the most cost-effective option for the majority of these houses. Furthermore, the findings suggest that the new construction residential market could be a target market for the large-scale introduction of a combination of condensing or power-vent water heaters with condensing furnaces.

Lekov, Alex B.; Franco, Victor H.; Wong-Parodi, Gabrielle; McMahon, James E.; Chan, Peter

2009-05-06T23:59:59.000Z

108

A Study on the Failure of Industrial Electric Heater  

E-Print Network [OSTI]

The break down mechanism of a cylindrical electric heater is investigated by studying the uneven heating behavior of the heater by measuring the surface temperature variation of the heater when it is subjected to a boundary condition of constant...

Chyu, M. C.

109

Heat Pump Water Heaters and American Homes: A Good Fit?  

E-Print Network [OSTI]

M.V. Lapsa. 2001. Residential Heat Pump Water Heater (HPWH)Calwell. 2005. Residential Heat Pump Water Heaters: EnergyA Specification for Residential Heat Pump Water Heaters

Franco, Victor

2011-01-01T23:59:59.000Z

110

Subsurface connection methods for subsurface heaters  

DOE Patents [OSTI]

A system for heating a subsurface formation is described. The system includes a first elongated heater in a first opening in the formation. The first elongated heater includes an exposed metal section in a portion of the first opening. The portion is below a layer of the formation to be heated. The exposed metal section is exposed to the formation. A second elongated heater is in a second opening in the formation. The second opening connects to the first opening at or near the portion of the first opening below the layer to be heated. At least a portion of an exposed metal section of the second elongated heater is electrically coupled to at least a portion of the exposed metal section of the first elongated heater in the portion of the first opening below the layer to be heated.

Vinegar, Harold J. (Bellaire, TX); Bass, Ronald Marshall (Houston, TX); Kim, Dong Sub (Sugar Land, TX); Mason, Stanley Leroy (Allen, TX); Stegemeier, George Leo (Houston, TX); Keltner, Thomas Joseph (Spring, TX); Carl, Jr., Frederick Gordon (Houston, TX)

2010-12-28T23:59:59.000Z

111

Absorption Heat Pump Water Heater - 2013 Peer Review | Department...  

Energy Savers [EERE]

Absorption Heat Pump Water Heater - 2013 Peer Review Absorption Heat Pump Water Heater - 2013 Peer Review Emerging Technologies Project for the 2013 Building Technologies Office's...

112

Residential Absorption Heat Pump Water Heater | Department of...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Heat Pump Water Heater Residential Absorption Heat Pump Water Heater Photo credit: Oak Ridge National Lab Photo credit: Oak Ridge National Lab Diagram of absorption heat...

113

Ex Parte Memorandum on Grid-Enabled Water Heaters | Department...  

Energy Savers [EERE]

with DOE representatives regarding water heater standards and thermal storage and demand response programs. DOE exparte memo100213 Grid-EnabledWaterHeaterAmendment More...

114

Covered Product Category: Residential Heat Pump Water Heaters...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Residential Heat Pump Water Heaters Covered Product Category: Residential Heat Pump Water Heaters The Federal Energy Management Program (FEMP) provides acquisition guidance and...

115

Efficient Residential Water Heaters Webinar | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Weatherization Assistance Program Pilot Projects Efficient Residential Water Heaters Webinar Efficient Residential Water Heaters Webinar On Feb. 22, 2011, Jerone Gagliano,...

116

Covered Product Category: Residential Gas Storage Water Heaters...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Storage Water Heaters Covered Product Category: Residential Gas Storage Water Heaters The Federal Energy Management Program (FEMP) provides acquisition guidance for gas storage...

117

Energy Cost Calculator for Electric and Gas Water Heaters | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Electric and Gas Water Heaters Energy Cost Calculator for Electric and Gas Water Heaters Vary equipment size, energy cost, hours of operation, and or efficiency level. INPUT...

118

DOE Publishes Notice of Proposed Rulemaking for Residential Water Heater and Certain Commercial Water Heater Test Procedures  

Broader source: Energy.gov [DOE]

The Department of Energy has published a notice of proposed rulemaking regarding test procedures for residential water heaters and certain commercial water heaters.

119

Tankless or Demand-Type Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Tankless or Demand-Type Water Heaters Tankless or Demand-Type Water Heaters Tankless or Demand-Type Water Heaters May 2, 2012 - 6:47pm Addthis Diagram of a tankless water heater. Diagram of a tankless water heater. How does it work? Tankless water heaters deliver hot water as it is needed, eliminating the need for storage tanks. Tankless water heaters, also known as demand-type or instantaneous water heaters, provide hot water only as it is needed. They don't produce the standby energy losses associated with storage water heaters, which can save you money. Here you'll find basic information about how they work, whether a tankless water heater might be right for your home, and what criteria to use when selecting the right model. Check out the Energy Saver 101: Water Heating infographic to learn if a tankless water heater is right for you.

120

Solar Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Solar Water Heaters Solar Water Heaters Solar Water Heaters May 7, 2012 - 9:52am Addthis Solar water heaters -- also called solar domestic hot water systems -- can be a cost-effective way to generate hot water for your home. They can be used in any climate, and the fuel they use -- sunshine -- is free. How They Work Solar water heating systems include storage tanks and solar collectors. There are two types of solar water heating systems: active, which have circulating pumps and controls, and passive, which don't. Active Solar Water Heating Systems There are two types of active solar water heating systems: Direct circulation systems Pumps circulate household water through the collectors and into the home. They work well in climates where it rarely freezes. Indirect circulation systems

Note: This page contains sample records for the topic "hydronic space heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Solar water heaters | Open Energy Information  

Open Energy Info (EERE)

heaters heaters Jump to: navigation, search (The following text is derived from the United States Department of Energy's description of Solar Water Heating technology.)[1] Solar Water Heater One of the most cost-effective ways to include renewable technologies into a building is by incorporating solar hot water. A typical residential solar water-heating system reduces the need for conventional water heating by about two-thirds. It minimizes the expense of electricity or fossil fuel to heat the water and reduces the associated environmental impacts. Solar Water Heating for Buildings Most solar water-heating systems for buildings have two main parts: (1) a solar collector and (2) a storage tank. The most common collector used in solar hot water systems is the flat-plate collector. Solar water heaters use the sun to heat either water

122

Heater head for a Stirling engine  

SciTech Connect (OSTI)

A heater head is described for a compound Stirling engine modules, each including a displacer cylinder coaxially aligned with the displacer cylinder of the other of the engine modules, a displacer piston mounted for reciprocation in the displacer cylinder.

Darooka, D.K.

1988-09-06T23:59:59.000Z

123

Arnold Schwarzenegger WATER HEATERS AND HOT WATER  

E-Print Network [OSTI]

Arnold Schwarzenegger Governor WATER HEATERS AND HOT WATER DISTRIBUTION SYSTEMS;#12;Appendices Appendix A. Multifamily Water Heating Construction Practices, Pricing and Availability Survey Report Appendix B. Multifamily Water Heating Controls Performance Field Report Appendix C. Pipe

124

Heat Pump Water Heaters Demonstration Project  

Broader source: Energy.gov (indexed) [DOE]

Heat Pump Water Heaters Heat Pump Water Heaters Demonstration Project Building America Stakeholder Meeting Ron Domitrovic Ammi Amarnath 3/1/2012 Austin, TX 2 © 2011 Electric Power Research Institute, Inc. All rights reserved. HPWH Field Demonstration: Research Objectives * Assess heat pump water heater technology by measuring efficiency. * Provide credible data on the performance and reliability of heat pump water heaters. * Assess user satisfaction in a residential setting. 3 © 2011 Electric Power Research Institute, Inc. All rights reserved. Demonstration Host Utilities Target: 40 Units per Utility Installed and Potential Sites by Climate Zone Source: Department of Energy (DOE), Building America climate regions 4 © 2011 Electric Power Research Institute, Inc. All rights reserved. Installation Locations-Southern Company Region

125

Varying properties along lengths of temperature limited heaters  

DOE Patents [OSTI]

A system for heating a subsurface formation is described. The system includes an elongated heater in an opening in the formation. The elongated heater includes two or more portions along the length of the heater that have different power outputs. At least one portion of the elongated heater includes at least one temperature limited portion with at least one selected temperature at which the portion provides a reduced heat output. The heater is configured to provide heat to the formation with the different power outputs. The heater is configured so that the heater heats one or more portions of the formation at one or more selected heating rates.

Vinegar, Harold J. (Bellaire, TX); Xie, Xueying (Houston, TX); Miller, David Scott (Katy, TX); Ginestra, Jean Charles (Richmond, TX)

2011-07-26T23:59:59.000Z

126

Phase change material storage heater  

DOE Patents [OSTI]

A storage heater for storing heat and for heating a fluid, such as water, has an enclosure defining a chamber therein. The chamber has a lower portion and an upper portion with a heating element being disposed within the enclosure. A tube through which the fluid flows has an inlet and an outlet, both being disposed outside of the enclosure, and has a portion interconnecting the inlet and the outlet that passes through the enclosure. A densely packed bed of phase change material pellets is disposed within the enclosure and is surrounded by a viscous liquid, such as propylene glycol. The viscous liquid is in thermal communication with the heating element, the phase change material pellets, and the tube and transfers heat from the heating element to the pellets and from the pellets to the tube. The viscous fluid has a viscosity so that the frictional pressure drop of the fluid in contact with the phase change material pellets substantially reduces vertical thermal convection in the fluid. As the fluid flows through the tube heat is transferred from the viscous liquid to the fluid flowing through the tube, thereby heating the fluid.

Goswami, D. Yogi (Gainesville, FL); Hsieh, Chung K. (Gainesville, FL); Jotshi, Chand K. (Gainesville, FL); Klausner, James F. (Gainesville, FL)

1997-01-01T23:59:59.000Z

127

Diesel particulate filter with zoned resistive heater  

DOE Patents [OSTI]

A diesel particulate filter assembly comprises a diesel particulate filter (DPF) and a heater assembly. The DPF filters a particulate from exhaust produced by an engine. The heater assembly has a first metallic layer that is applied to the DPF, a resistive layer that is applied to the first metallic layer, and a second metallic layer that is applied to the resistive layer. The second metallic layer is etched to form a plurality of zones.

Gonze, Eugene V [Pinckney, MI

2011-03-08T23:59:59.000Z

128

Reducing NOx in Fired Heaters and Boilers  

E-Print Network [OSTI]

-6, 2000 Reducing NOx in Fired Heaters Air Pollution Control and Boilers Keeping the environment clean Presented by Ashutosh Garg Furnace Improvements Low cost solutions for fired heaters Trace compounds ? Nitric oxides ? Carbon monoxide ? Sulfur... it is essential to estimate accurately baseline NOx emissions. ? This will establish each units current compliance status. ? Emissions ? Current excess air level ? Carbon monoxide ? Combustibles ? NOx corrected to 3% 02 314 ESL-IE-00-04-46 Proceedings...

Garg, A.

129

Selecting a New Water Heater | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Selecting a New Water Heater Selecting a New Water Heater Selecting a New Water Heater August 29, 2012 - 7:30pm Addthis Water heater testing facility at Oak Ridge National Laboratory. Water heater testing facility at Oak Ridge National Laboratory. When selecting a new water heater for your home, choose a water heating system that will not only provide enough hot water but also that will do so energy efficiently, saving you money. This includes considering the different types of water heaters available and determining the right size and fuel source for your home. Check out the Energy Saver 101: Water Heating infographic to learn more about the different types of water heaters and how to select the right model for your home. Types of Water Heaters It's a good idea to know the different types of water heaters available

130

An International Survey of Electric Storage Tank Water Heater Efficiency and Standards  

E-Print Network [OSTI]

Survey of Electric Storage Tank Water Heater Efficiency andSurvey of Electric Storage Tank Water Heater Efficiency andby electric resistance storage tank water heaters (geysers),

Johnson, Alissa

2013-01-01T23:59:59.000Z

131

Temperature limited heaters using phase transformation of ferromagnetic material  

DOE Patents [OSTI]

Systems, methods, and heaters for treating a subsurface formation are described herein. Systems and methods for making heaters are described herein. At least one heater includes a ferromagnetic conductor and an electrical conductor. The electrical conductor is electrically coupled to the ferromagnetic conductor. The heater provides a first amount of heat at a lower temperature. The heater may provide a second reduced amount of heat when the heater reaches a selected temperature, or enters a selected temperature range, at which the ferromagnetic conductor undergoes a phase transformation.

Vitek, John Michael [Oak Ridge, TN; Brady, Michael Patrick [Oak Ridge, TN

2009-10-06T23:59:59.000Z

132

MHD oxidant intermediate temperature ceramic heater study. Final report  

SciTech Connect (OSTI)

The use of three types of directly fired ceramic heaters for preheating oxygen enriched air to an intermediate temperature of 1144K was investigated. The three types of ceramic heaters are: (1) a fixed bed, periodic flow ceramic brick regenerative heater (2) a ceramic pebble regenerative heater. The heater design, performance and operating characteristics under conditions in which the particulate matter is not solidified are evaluated. A comparison and overall evaluation of the three types of ceramic heaters and temperature range determination at which the particulate matter in the MHD exhaust gas is estimated to be a dry powder are presented.

Carlson, A.W.; Chait, I.L.; Saari, D.P.; Marksberry, C.L.

1981-09-01T23:59:59.000Z

133

Solar water heaters | Open Energy Information  

Open Energy Info (EERE)

water heaters water heaters (Redirected from - Solar Hot Water) Jump to: navigation, search (The following text is derived from the United States Department of Energy's description of Solar Water Heating technology.)[1] Solar Water Heater One of the most cost-effective ways to include renewable technologies into a building is by incorporating solar hot water. A typical residential solar water-heating system reduces the need for conventional water heating by about two-thirds. It minimizes the expense of electricity or fossil fuel to heat the water and reduces the associated environmental impacts. Solar Water Heating for Buildings Most solar water-heating systems for buildings have two main parts: (1) a solar collector and (2) a storage tank. The most common collector used in solar hot water systems is the

134

Solar Water Heater Rebate | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Solar Water Heater Rebate Solar Water Heater Rebate Solar Water Heater Rebate < Back Eligibility Commercial Fed. Government Residential Savings Category Heating & Cooling Solar Water Heating Program Info State Hawaii Program Type State Rebate Program Rebate Amount Residential Solar Water Heating: $1,000 upfront, or Residential Solar Water Heating Interest Loan Buy-Down: $1,000 Residential Solar Attic Fans: $50 Commercial: $250 per 12,000 Btu/hr derated capacity Provider Hawaii Energy Hawaii Energy, a third-party administered public benefits fund, provides incentives for energy efficiency and conservation to customers of the Hawaiian Electric Company (HECO) and its subsidiaries, Maui Electric Company (MECO) and Hawaii Electric Light Company (HELCO). This incentive is available for installations on the islands of Oahu, Hawaii, Maui, Lanai and

135

Regional Variation in Residential Heat Pump Water Heater Performance in the United States  

Broader source: Energy.gov (indexed) [DOE]

NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. Regional Variation in Residential Heat Pump Water Heater Performance in the US Jeff Maguire 4/30/13 Outline * Why HPWHs? * US Water Heating Market * Overview of HPWHs * Model Description * Results o HPWH Performance o Energy Savings Potential o Breakeven Cost 2 Heat Pump Water Heaters Save $300 a year over standard electric? Save $100 a year over standard gas? Heat Pump Electric Gas 3 Questions about HPWHs * Are HPWHs a good replacement for typical gas and electric storage water heaters? o In different locations across the country? o In conditioned/unconditioned space? o Source energy savings?

136

Building Technologies Office: HVAC and Water Heater Field Tests Research  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

HVAC and Water Heater HVAC and Water Heater Field Tests Research Project to someone by E-mail Share Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Facebook Tweet about Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Twitter Bookmark Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Google Bookmark Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Delicious Rank Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Digg Find More places to share Building Technologies Office: HVAC and Water Heater Field Tests Research Project on AddThis.com... About Take Action to Save Energy Partner with DOE Activities Appliances Research

137

Heat Pump Water Heater using Solid-State Energy Converters |...  

Energy Savers [EERE]

Heat Pump Water Heater using Solid-State Energy Converters Heat Pump Water Heater using Solid-State Energy Converters Sheetak will work on developing a full scale prototype of its...

138

Design, Stress Analysis and Operating Experience in Feedwater Heaters  

E-Print Network [OSTI]

The performance of feedwater heaters has a direct bearing on the thermal efficiency of the plant. A typical feedwater heater may have three distinct regions of heat transfer, namely desuperheating, condensing and subcooling zones. The design...

Singh, K. P.; Libs, T.

1980-01-01T23:59:59.000Z

139

TVA Partner Utilities- Energy Right Water Heater Program  

Broader source: Energy.gov [DOE]

The TVA energy right Water Heater Plan promotes the installation of high efficiency water heaters in homes and small businesses. TVA provides a $50 incentive to local power companies for each...

140

TVA Partner Utilities- Energy Right Water Heater Program  

Broader source: Energy.gov [DOE]

The Tennessee Valley Authority (TVA) energy right Water Heater Plan promotes the installation of high efficiency water heaters in homes and small businesses. TVA provides a $50 incentive to local...

Note: This page contains sample records for the topic "hydronic space heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Making Water Heaters More Efficient | GE Global Research  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Water Heaters More Efficient Making Water Heaters More Efficient Jigar Shah 2013.11.13 As children, many of us grow up wanting to make some sort of lasting positive impact on...

142

NREL Evaluates Performance of Heat Pump Water Heaters (Fact Sheet)  

SciTech Connect (OSTI)

NREL evaluates energy savings potential of heat pump water heaters in homes throughout all U.S. climate zones.

Not Available

2012-02-01T23:59:59.000Z

143

Covered Product Category: Commercial Gas Water Heaters  

Broader source: Energy.gov [DOE]

FEMP provides acquisition guidance and Federal efficiency requirements across a variety of product categories, including commercial gas water heaters, which are covered by the ENERGY STAR® program. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

144

Our Environment in Hot Water: Comparing Water Heaters, A Life Cycle Approach Comparing Tank and Tankless Water Heaters in California  

E-Print Network [OSTI]

Diagram 1: A Typical Tank Water Heater Source: http://to-unit comparisons of tank versus tankless water heaters.Energy Use MJ/(unit*year) Tank Tankless MJ/(unit*year) Tank

Lu, Alison

2011-01-01T23:59:59.000Z

145

Technical evaluation of a solar heating system having conventional hydronic solar collectors and a radiant panel slab. Final report  

SciTech Connect (OSTI)

A simple innovative solar heating design (Solar Option One) using conventional hydronic solar collectors and a radiant panel slab was constructed. An objective of hybrid solar design is to combine the relative advantages of active and passive design approaches while minimizing their respective disadvantages. A test house using the Solar Option One heating system was experimentally monitored to determine its energy based performance during the 1982-83 heating season. The test residence is located in Lyndonville, Vermont, an area which has a characteristically cold and cloudy climate. The two story residence has a floor area of about 1400 square feet and is constructed on a 720 square foot 5.5 inch thick floor slab. A 24 inch packed gravel bed is located beneath the slab and the slab-gravel bed is insulated by two inches of polystyrene insulation. The test building is of frame construction and uses insulation levels which have become commonplace throughout the country. The structure would not fall into the superinsulated category but was tightly constructed so as to have a low infiltration level. The building is sun-tempered in that windows were concentrated somewhat on the South side and all but avoided on the North. A solar greenhouse on the South side of the building was closed off from the structure permanently throughout the testing so as to better observe the solar heating invention without confounding variables. The monitoring equipment generated an internal gain of about 17,000 BTUs per day, roughly the equivalent of occupancy by two persons. A full description of the experimental testing program is given. System efficiency and performance are reported.

Starr, R.J.

1984-04-01T23:59:59.000Z

146

Building America Expert Meeting: Multifamily Hydronic and Steam Heating Controls and Distribution Retrofits  

Broader source: Energy.gov [DOE]

This expert meeting was conducted on July 13, 2011 by the ARIES Collaborative in New York City. The topic of this expert meeting was cost-effective controls and distribution retrofit options for hot water and steam space heating systems in multi-family buildings with the goals of reducing energy waste and improving occupant comfort.

147

Solar space and water heating system at Stanford University Central Food Services Building. Final report  

SciTech Connect (OSTI)

This active hydronic domestic hot water and space heating system was 840 ft/sup 2/ of single-glazed, liquid, flat plate collectors and 1550 gal heat storage tanks. The following are discussed: energy conservation, design philosophy, operation, acceptance testing, performance data, collector selection, bidding, costs, economics, problems, and recommendations. An operation and maintenance manual and as-built drawings are included in appendices. (MHR)

Not Available

1980-05-01T23:59:59.000Z

148

An Overview of the New Residential Water Heater Efficiency Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

An Overview of the New Residential Water Heater Efficiency Standards An Overview of the New Residential Water Heater Efficiency Standards Speaker(s): Alex Lekov Date: April 26, 2010 - 12:00pm Location: 90-3122 DOE issued new standards for residential water heaters last month that will save an estimated 2.6 quads of energy over 30 years. For most product sizes sold, the new standards can be met with modest changes, such as adding more insulation to today's conventional tank-style water heaters. For the most common size electric water heater (50 gallons), the standards will save 4 percent, while for the most common size gas water heater (40 gallons), the new standards will save 3 percent. However, for the biggest products (those with over 55 gallons in storage capacity, which is about 9% and 4% of the electric and gas storage water heater markets, respectively), the new

149

TVA Partner Utilities - Energy Right' Water Heater Program | Department of  

Broader source: Energy.gov (indexed) [DOE]

Right' Water Heater Program Right&#039; Water Heater Program TVA Partner Utilities - Energy Right' Water Heater Program < Back Eligibility Installer/Contractor Residential Utility Savings Category Appliances & Electronics Water Heating Maximum Rebate Member utility water heater rebate programs can range from $25 to total cost. Program Info State Mississippi Program Type Utility Rebate Program Rebate Amount Energy Efficient Water Heater: $50 from TVA Provider Tennessee Valley Authority The TVA energy right Water Heater Plan promotes the installation of high efficiency water heaters in homes and small businesses. TVA provides a $50 incentive to local power companies for each installation. Power Companies may pass these incentives on to customers. Customers should contact their local power company to see what programs are

150

Burbank Water and Power - Solar Water Heater Rebate Program (California) |  

Broader source: Energy.gov (indexed) [DOE]

Burbank Water and Power - Solar Water Heater Rebate Program Burbank Water and Power - Solar Water Heater Rebate Program (California) Burbank Water and Power - Solar Water Heater Rebate Program (California) < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Program Info State California Program Type Utility Rebate Program Rebate Amount $1,500 Provider Rebates Burbank Water and Power is providing incentives for the purchase of solar water heaters. Incentives are only available to residential customers with electric water heaters. There is a limit of one solar water heater per year per property. Applicants must provide access to their residence for a pre-inspection to verify the existing use of an electric water heater. Customers must comply with all code and permit requirements. More

151

Advanced refinery process heater. Annual report, October 1983-September 1984  

SciTech Connect (OSTI)

Activity during the first year of this project has focused on the conceptual design of the prototype heater and on the development of a custom-designed Pyrocore ceramic fiber burner for the heater. Three different concepts for the prototype heater have been produced, one of them modeled after a vertical cylindrical design and the other two resembling box-type heaters. All three concepts take advantage of the Pyrocore burner's flameless characteristic to make the heater more compact. Concerning the development of the burners, two different geometries were considered. Subscale prototypes of each type of burner were fabricated and tested. The more successful burners used actively-cooled edges to maintain the integrity of the gas-tight seals. Work on this project in the second year will include the design and fabrication of the 10 MMBtu/hr prototype heater, using the most feasible heater and burner designs developed during the first year.

Schreiber, R.J.; Gotterba, J.A.; Minden, A.C.

1984-10-01T23:59:59.000Z

152

Condensing Hybrid Water Heater Monitoring Field Evaluation  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Condensing Hybrid Water Heater Condensing Hybrid Water Heater Monitoring Field Evaluation Jeff Maguire, Lieko Earle, and Chuck Booten National Renewable Energy Laboratory C.E. Hancock Mountain Energy Partnership Produced under direction of the Sacramento Municipal Utilities District by the National Renewable Energy Laboratory (NREL) under Interagency Agreement CRD-05-168 and Task No WR49.3000. Technical Report NREL/TP-5500-52234 October 2011 NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency & Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. National Renewable Energy Laboratory 1617 Cole Boulevard Golden, Colorado 80401 303-275-3000 * www.nrel.gov Contract No. DE-AC36-08GO28308

153

AWSWAH - the heat pipe solar water heater  

SciTech Connect (OSTI)

An all weather heat pipe solar water heater (AWSWAH) comprising a collector of 4 m/sup 2/ (43 ft/sup 2/) and a low profile water tank of 160 liters (42 gal.) was developed. A single heat pipe consisting of 30 risers and two manifolds in the evaporator and a spiral condenser was incorporated into the AWSWAH. Condensate metering was done by synthetic fiber wicks. The AWSWAH was tested alongside two conventional solar water heaters of identical dimensions, an open loop system and a closed loop system. It was found that the AWSWAH was an average of 50% more effective than the open system in the temperature range 30-90 /sup 0/C (86-194 /sup 0/F). The closed loop system was the least efficient of the three systems.

Akyurt, M.

1986-01-01T23:59:59.000Z

154

Cryostat including heater to heat a target  

DOE Patents [OSTI]

A cryostat is provided which comprises a vacuum vessel; a target disposed within the vacuum vessel; a heat sink disposed within the vacuum vessel for absorbing heat from the detector; a cooling mechanism for cooling the heat sink; a cryoabsorption mechanism for cryoabsorbing residual gas within the vacuum vessel; and a heater for maintaining the target above a temperature at which the residual gas is cryoabsorbed in the course of cryoabsorption of the residual gas by the cryoabsorption mechanism. 2 figs.

Pehl, R.H.; Madden, N.W.; Malone, D.F.

1990-09-11T23:59:59.000Z

155

Carbon Dioxide Heat Pump Water Heater Research Project | Department of  

Broader source: Energy.gov (indexed) [DOE]

Emerging Technologies » Carbon Dioxide Heat Pump Water Heater Emerging Technologies » Carbon Dioxide Heat Pump Water Heater Research Project Carbon Dioxide Heat Pump Water Heater Research Project The U.S. Department of Energy is currently conducting research into carbon dioxide (CO2) heat pump water heaters. This project will employ innovative techniques to adapt water heating technology to meet U.S. market requirements, including specifications, cost, and performance targets. Carbon dioxide is a refrigerant with a global warming potential (GWP) of 1. The CO2 heat pump water heater research seeks to develop an improved life cycle climate performance compared to conventional refrigerants. For example, R134a, another type of refrigerant, has a GWP of 1,300. Project Description This project seeks to develop a CO2-based heat pump water heater (HPWH)

156

Aiken Electric Cooperative Inc - Residential Water Heater Rebate Program |  

Broader source: Energy.gov (indexed) [DOE]

Aiken Electric Cooperative Inc - Residential Water Heater Rebate Aiken Electric Cooperative Inc - Residential Water Heater Rebate Program Aiken Electric Cooperative Inc - Residential Water Heater Rebate Program < Back Eligibility Residential Savings Category Appliances & Electronics Water Heating Program Info State South Carolina Program Type Utility Rebate Program Rebate Amount Free high efficiency water Heater; $200 installation fee Water heater and timer with normal installation: $2.50 credit for 10 years Timer only: $200 cash payment and $2.50 credit for 10 years New construction contract home: $250 Provider Aiken Electric Cooperative Aiken Electric Cooperative offers residential members rebates for installing high-efficiency electric water heaters and/or timers in their homes. Customers have four rebate options:

157

Coweta-Fayette EMC - Residential Solar Water Heater Rebate Program  

Broader source: Energy.gov (indexed) [DOE]

Coweta-Fayette EMC - Residential Solar Water Heater Rebate Program Coweta-Fayette EMC - Residential Solar Water Heater Rebate Program (Georgia) Coweta-Fayette EMC - Residential Solar Water Heater Rebate Program (Georgia) < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Program Info State Georgia Program Type Utility Rebate Program Rebate Amount Existing Homes Solar Water Heater: $750 New Homes Solar Water Heater: $1,250 - $1,500 Provider Coweta-Fayette Electric Membership Corporation Coweta-Fayette Electric Membership Corporation (EMC) provides electric and natural gas service to 58,000 customers in Georgia's Coweta, Fayette, Meriwether, Heard, Troop and Fulton counties. Currently, Coweta-Fayette EMC offers rebates on solar water heaters from $750 up to $1,500 as part of the Touchstone Energy Home Program. Solar

158

The Trials and Tribulations of Testing Water Heaters  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

The Trials and Tribulations of Testing Water Heaters The Trials and Tribulations of Testing Water Heaters Speaker(s): James Lutz Date: August 14, 2001 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Julie Osborn During our work on efficiency standards for electric water heaters, we discovered significant discrepancies between the rated and tested efficiencies of the highest rated electric resistance water heaters. For high efficiency electric resistance water heaters with an Energy Factor above .92, the heat losses are so small that minor flaws in the tank or obscure problems in the test procedure become more apparent. This seminar reports on our investigation into the causes of inconsistent results obtained during testing of high efficiency electric resistance water heaters at different test labs. We discovered some reasons for the

159

Linn County Rural Electric Cooperative - Solar Water Heater Rebate Program  

Broader source: Energy.gov (indexed) [DOE]

Linn County Rural Electric Cooperative - Solar Water Heater Rebate Linn County Rural Electric Cooperative - Solar Water Heater Rebate Program Linn County Rural Electric Cooperative - Solar Water Heater Rebate Program < Back Eligibility Agricultural Commercial Residential Savings Category Heating & Cooling Solar Water Heating Program Info State Iowa Program Type Utility Rebate Program Rebate Amount $500 Provider Linn County Rural Electric Cooperative Association Linn County Rural Electric Cooperative Association (Linn County RECA) is a member-owned cooperative. To encourage energy efficiency, Linn County offers a number of rebates to commercial, residential, and agricultural customers. Owners of both new construction and existing buildings are eligible for a $500 rebate for solar water heaters. The water heaters must have an auxiliary tank of at least 40 gallons and the solar water heater

160

Rock Hill Utilities - Water Heater and Heat Pump Rebate Program |  

Broader source: Energy.gov (indexed) [DOE]

Rock Hill Utilities - Water Heater and Heat Pump Rebate Program Rock Hill Utilities - Water Heater and Heat Pump Rebate Program Rock Hill Utilities - Water Heater and Heat Pump Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heat Pumps Appliances & Electronics Water Heating Program Info State South Carolina Program Type Utility Rebate Program Rebate Amount Water Heater: up to $275 Heat Pump Replacement: $400 Provider Rock Hill Utilities Through the SmartChoice program, Rock Hill Utilities offers rebates for water heater and heat pump replacements. Information on financing for heat pumps can also be found on the web site listed above. If both the water heater and heat pump are purchased then the customer may qualify for the Great Rate program. The Great Rate program will add a 25% discount to a

Note: This page contains sample records for the topic "hydronic space heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Multi-step heater deployment in a subsurface formation  

DOE Patents [OSTI]

A method for installing a horizontal or inclined subsurface heater includes placing a heating section of a heater in a horizontal or inclined section of a wellbore with an installation tool. The tool is uncoupled from the heating section. A lead in section is mechanically and electrically coupled to the heating section of the heater. The lead-in section is located in an angled or vertical section of the wellbore.

Mason, Stanley Leroy (Allen, TX)

2012-04-03T23:59:59.000Z

162

Insulated conductor temperature limited heater for subsurface heating coupled in a three-phase WYE configuration  

DOE Patents [OSTI]

A heating system for a subsurface formation is described. The heating system includes a first heater, a second heater, and a third heater placed in an opening in the subsurface formation. Each heater includes: an electrical conductor; an insulation layer at least partially surrounding the electrical conductor; and an electrically conductive sheath at least partially surrounding the insulation layer. The electrical conductor is electrically coupled to the sheath at a lower end portion of the heater. The lower end portion is the portion of the heater distal from a surface of the opening. The first heater, the second heater, and the third heater are electrically coupled at the lower end portions of the heaters. The first heater, the second heater, and the third heater are configured to be electrically coupled in a three-phase wye configuration.

Vinegar, Harold J. (Bellaire, TX); Sandberg, Chester Ledlie (Palo Alto, CA)

2010-11-09T23:59:59.000Z

163

Advanced refinery process heater. Final report, (October 1983-September 1988)  

SciTech Connect (OSTI)

A prototype refinery process heater was designed, built and successfully tested, demonstrating the improvements available to heater design through the use of Zone-Controlled Pyrocore radiant gas burners. The 10 MMBtu/hr rated heater released 17 ppm NOx (corrected to 3% oxygen) under full load operation, the lowest NOx emissions technically and commercially achieved in this type of equipment without the use of post-combustion flue-gas processing. Operating with 400F combustion air preheat and a 500F process fluid outlet temperature, the heater achieved overall thermal efficiencies of 92.8% on a LHV basis due in part to the significantly improved performance of the radiant heat exchange section. The radiant burners used in the heater have been proven in performance and reliability, and have also been shown to be applicable to both new heater designs and retrofits into existing heaters. The improved radiant performance of the heater and the use of 'flameless' radiant burners eliminates tube burn-out failures in both the radiant and convective tube coils, further improving the reliability of equipment based on this design. Three separate U.S. Patents have been issued covering the heater design and the use of Zone-Controlled Pyrocore burners in this application.

Minden, A.C.; Buckley, G.G.

1989-04-01T23:59:59.000Z

164

NREL Develops Heat Pump Water Heater Simulation Model (Fact Sheet)  

SciTech Connect (OSTI)

A new simulation model helps researchers evaluate real-world impacts of heat pump water heaters in U.S. homes.

Hudon, K.

2012-05-01T23:59:59.000Z

165

Heat Pump Water Heaters and American Homes: A Good Fit?  

E-Print Network [OSTI]

as conventional electric resistance water heaters, with thetwo technologies: (1) an electric resistance storage watertransfers heat from the electric resistance element to the

Franco, Victor

2011-01-01T23:59:59.000Z

166

Slurry fired heater cold-flow modelling  

SciTech Connect (OSTI)

This report summarizes the experimental and theoretical work leading to the scale-up of the SRC-I Demonstration Plant slurry fired heater. The scale-up involved a theoretical model using empirical relations in the derivation, and employed variables such as flow conditions, liquid viscosity, and slug frequency. Such variables have been shown to affect the heat transfer characteristics ofthe system. The model assumes that, if all other variables remain constant, the heat transfer coefficient can be scaled up proportional to D/sup -2/3/ (D = inside diameter of the fired heater tube). All flow conditions, liquid viscosities, and pipe inclinations relevant to the demonstration plant have indicated a slug flow regime in the slurry fired heater. The annular and stratified flow regimes should be avoided to minimize the potential for excessive pipe erosion and to decrease temperature gradients along the pipe cross section leading to coking and thermal stresses, respectively. Cold-flow studies in 3- and 6.75-in.-inside-diameter (ID) pipes were conducted to determine the effect of scale-up on flow regime, slug frequency, and slug dimensions. The developed model assumes that conduction heat transfer occurs through the liquid film surrounding the gas slug and laminar convective heat transfer to the liquid slug. A weighted average of these two heat transfer mechanisms gives a value for the average pipe heat transfer coefficient. The cold-flow work showed a decrease in the observed slug frequency between the 3- and 6.75-ID pipes. Data on the ratio of gas to liquid slug length in the 6.75-in. pipe are not yet complete, but are expected to yield generally lower values than those obtained in the 3-in. pipe; this will probably affect the scale-up to demonstration plant conditions. 5 references, 15 figures, 7 tables.

Moujaes, S.F.

1983-07-01T23:59:59.000Z

167

Georgia Power- Residential Solar and Heat Pump Water Heater Rebate (Georgia)  

Broader source: Energy.gov [DOE]

Georgia Power customers may be eligible for rebates up to $250 each toward the installation costs of a 50 gallon or greater solar water heater or heat pump water heater. The solar water heater or...

168

ELECTRICAL HEATERS FOR THERMO-MECHANICAL TESTS AT THE STRIPA MINE  

E-Print Network [OSTI]

5.5 Dewatering Pump 6. ELECTRICAL HEATER CONTROL SYSTEMS 6.1water influx ABSTRACT Electrical heaters were installed atcanister) which houses the electrical heater elements; c. d.

Burleigh, R.H.

2010-01-01T23:59:59.000Z

169

Solar pool heaters: The simplest use of active solar energy  

SciTech Connect (OSTI)

Solar pool heating is the most attractive solar water heating market today, because most pool heaters pay back their purchase price in lower utility bills in two to three years. This article describes why solar pool heaters are popular and their design, operation, and return on investment. 1 fig.

Sheinkopf, K. [Florida Solar Energy Center, Cocoa, FL (United States)

1997-11-01T23:59:59.000Z

170

Tri-County Electric Cooperative - Energy Efficient Water Heater Rebate  

Broader source: Energy.gov (indexed) [DOE]

Tri-County Electric Cooperative - Energy Efficient Water Heater Tri-County Electric Cooperative - Energy Efficient Water Heater Rebate Program Tri-County Electric Cooperative - Energy Efficient Water Heater Rebate Program < Back Eligibility Commercial Residential Savings Category Appliances & Electronics Water Heating Program Info State Texas Program Type Utility Rebate Program Rebate Amount $75 Provider Tri-County Electric Cooperative Tri-County Electric Cooperative offers a $75 rebate on the purchase of energy-efficient electric water heaters. The rebate is valid for new or replacement units which have an Energy Factor Rating of 0.90 or higher. The minimum tank size is 40 gallons, with a minimum 4,500 watt heating element. For validation purposes, a copy of the sales or installation receipt must accompany the [http://www.tcectexas.com/Forms/water%20heater%20rebate%20form.pdf

171

Clay Electric Cooperative, Inc - Energy Smart Solar Water Heater Rebate  

Broader source: Energy.gov (indexed) [DOE]

Clay Electric Cooperative, Inc - Energy Smart Solar Water Heater Clay Electric Cooperative, Inc - Energy Smart Solar Water Heater Rebate Program Clay Electric Cooperative, Inc - Energy Smart Solar Water Heater Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Maximum Rebate $600 Program Info State Florida Program Type Utility Rebate Program Rebate Amount 0.01 per BTU output Provider Clay Electric Co-op Clay Electric Cooperative (CEC) provides a rebate of $0.01 per BTU output to its residential members when they purchase qualified solar water heaters. This rebate is capped at 60,000 BTUs per system, or $600. Eligible solar water heaters can be either passive or active systems. The proposed solar system must meet Florida Solar Energy Center (FSEC) specifications and be installed by a contractor certified to install solar water heating

172

Heat Pump Swimming Pool Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Swimming Pool Heaters Swimming Pool Heaters Heat Pump Swimming Pool Heaters May 29, 2012 - 1:49pm Addthis How a heat pump works. How a heat pump works. How They Work Heat pumps use electricity to capture heat and move it from one place to another. They don't generate heat. As the pool pump circulates the swimming pool's water, the water drawn from the pool passes through a filter and the heat pump heater. The heat pump heater has a fan that draws in the outside air and directs it over the evaporator coil. Liquid refrigerant within the evaporator coil absorbs the heat from the outside air and becomes a gas. The warm gas in the coil then passes through the compressor. The compressor increases the heat, creating a very hot gas that then passes through the condenser. The condenser transfers the heat from the hot gas to the cooler pool water circulating

173

Cost of Increased Energy Efficiency for Residential Water Heaters  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Cost of Increased Energy Efficiency for Residential Water Heaters Cost of Increased Energy Efficiency for Residential Water Heaters Speaker(s): Alex Lekov Date: March 22, 2001 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Julie Osborn This presentation describes the analysis of the costs of increased energy efficiency for residential water heaters. Here, we focus on the cost and efficiency data for electric and gas-fired water heaters. This data formed the basis of the Technical Support Document for the Department of Energy's (DOE) Final Rule on Water Heaters. The engineering analysis uses computer simulation models to investigate the efficiency improvements due to design options and combinations thereof. The analysis covers four polyurethane foam insulation types based on non-ozone-depleting substances as blowing

174

Tankless Demand Water Heater Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Demand Water Heater Basics Demand Water Heater Basics Tankless Demand Water Heater Basics August 19, 2013 - 2:57pm Addthis Illustration of an electric demand water heater. At the top of the image, the heating unit is shown. Cold water flows in one end of a pipe, flows through and around several curved pipes over the heating elements, and out the other end as hot water. Beneath the heating unit, a typical sink setup is shown. The sink has two pipes coming out the bottom, one for the hot water line and one for the cold water line. Both pipes lead to the heating unit, which is installed in close proximity to the area of hot water use, and is connected to a power source (110 or 220 volts). Demand (tankless or instantaneous) water heaters have heating devices that are activated by the flow of water, so they provide hot water only as

175

Tankless Demand Water Heater Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Tankless Demand Water Heater Basics Tankless Demand Water Heater Basics Tankless Demand Water Heater Basics August 19, 2013 - 2:57pm Addthis Illustration of an electric demand water heater. At the top of the image, the heating unit is shown. Cold water flows in one end of a pipe, flows through and around several curved pipes over the heating elements, and out the other end as hot water. Beneath the heating unit, a typical sink setup is shown. The sink has two pipes coming out the bottom, one for the hot water line and one for the cold water line. Both pipes lead to the heating unit, which is installed in close proximity to the area of hot water use, and is connected to a power source (110 or 220 volts). Demand (tankless or instantaneous) water heaters have heating devices that are activated by the flow of water, so they provide hot water only as

176

Clark Public Utilities - Solar Water Heater Rebate | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Clark Public Utilities - Solar Water Heater Rebate Clark Public Utilities - Solar Water Heater Rebate Clark Public Utilities - Solar Water Heater Rebate < Back Eligibility Commercial Residential Savings Category Heating & Cooling Solar Water Heating Program Info State District of Columbia Program Type Utility Rebate Program Rebate Amount $500 Provider Clark PUD Clark Public Utilities offers a rebate of $500 to customers who install a solar water heating system. Customers must own the residence or business where the solar water heating system is installed and must have an electric water heater. In addition, Clark Public Utilities offers a [http://dsireusa.org/incentives/incentive.cfm?Incentive_Code=WA29F&re=1&ee=1 loan program] for eligible solar water heater equipment. For additional information, call Energy Services at (360) 992-3355.

177

Solar Water Heater Roadmap Leads Path to Market Expansion (Fact Sheet)  

SciTech Connect (OSTI)

Innovative strategy to reduce installed cost of solar water heater systems can rival conventional natural gas water heaters in the marketplace.

Not Available

2012-09-01T23:59:59.000Z

178

Evaluation of TANK water heater simulation model as embedded in HWSim  

E-Print Network [OSTI]

this scheme for operating TANK with HWSim is successful.LBNL # Evaluation of TANK water heater simulation model asCalifornia. Evaluation of TANK water heater simulation model

Lutz, Jim

2012-01-01T23:59:59.000Z

179

Review of International Methods of Test to Rate the Efficiency of Water Heaters  

E-Print Network [OSTI]

Conservation Standards for Residential Water Heaters, Direct Heating Equipment, and PoolConservation Program for Consumer Products: Test Procedures for Residential Water Heaters, Direct Heating Equipment, and Pool

Lutz, Jim

2012-01-01T23:59:59.000Z

180

Ductless Hydronic Distribution  

Broader source: Energy.gov [DOE]

This presentation was given at the Summer 2012 DOE Building America meeting on July 25, 2012, and addressed the question "What emerging innovations are the key to future homes?"

Note: This page contains sample records for the topic "hydronic space heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Space  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Energy Earth Materials Science Technology The Lab All Paul Johnson Unusual light in dark space revealed by Los Alamos, NASA By looking at the dark spaces between visible...

182

Heat Pump Water Heater Performance in  

Broader source: Energy.gov (indexed) [DOE]

searc searc e er tra A Research Institute of the University of Central Florida FLORIDA SOLAR ENERGY CENTER - A Re h Institut of the Univ sity of Cen l Florida searc e er tra Heat Pump Water Heater Performance in Laboratory House Building America Technical Update 2013 ACI National Home Performance Conference April 29- 30 , 2013 Carlos J. Colon carlos@fsec.ucf.edu A Research Institute of the University of Central Florida FLORIDA SOLAR ENERGY CENTER - A Re h Institut of the Univ sity of Cen l Florida FLORIDA SOLAR ENERGY CENTER - A Research Institute of the University of Central Florida Hot Water Systems (HWS) Laboratory FSEC Grounds, Florida (east coast) 2009 -Present (Currently fourth testing rotation) FLORIDA SOLAR ENERGY CENTER - A Research Institute of the University of Central Florida

183

Utilization of Heat Pump Water Heaters for Load Management  

SciTech Connect (OSTI)

The Energy Conservation Standards for Residential Water Heaters require residential electric storage water heaters with volumes larger than 55 gallons to have an energy factor greater than 2.0 after April 2015. While this standard will significantly increase the energy efficiency of water heaters, large electric storage water heaters that do not use heat pump technologies may no longer be available. Since utilities utilize conventional large-volume electric storage water heaters for thermal storage in demand response programs, there is a concern that the amended standard will significantly limit demand response capacity. To this end, Oak Ridge National Laboratory partnered with the Tennessee Valley Authority to investigate the load management capability of heat pump water heaters that meet or exceed the forthcoming water heater standard. Energy consumption reduction during peak periods was successfully demonstrated, while still meeting other performance criteria. However, to minimize energy consumption, it is important to design load management strategies that consider the home s hourly hot water demand so that the homeowner has sufficient hot water.

Boudreaux, Philip R [ORNL; Jackson, Roderick K [ORNL; Munk, Jeffrey D [ORNL; Gehl, Anthony C [ORNL; Lyne, Christopher T [ORNL

2014-01-01T23:59:59.000Z

184

Blue Ridge Mountain Electric Membership Corporation - Water Heater Rebate  

Broader source: Energy.gov (indexed) [DOE]

You are here You are here Home » Blue Ridge Mountain Electric Membership Corporation - Water Heater Rebate Program Blue Ridge Mountain Electric Membership Corporation - Water Heater Rebate Program < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Sealing Your Home Heating & Cooling Commercial Heating & Cooling Cooling Construction Design & Remodeling Ventilation Manufacturing Heat Pumps Appliances & Electronics Water Heating Program Info State Georgia Program Type Utility Rebate Program Rebate Amount In-Home Energy Evaluation Program Windows: $500 Duct Repair: $500 Rehabilitation Work: $250 HVAC Replacement: $250/unit HVAC Tune-up: $150/unit Insulation: $500 Water Heater and Pipe Insulation: $50 Air Sealing: $500 Energy Right Program

185

THE EFFECT OF LOCATION OF THE PREDICTED PERFORMANCE OF A HEAT PUMP WATER HEATER  

E-Print Network [OSTI]

#12;THE EFFECT OF LOCATION OF THE PREDICTED PERFORMANCE OF A HEAT PUMP WATER HEATER Laboratory testing and field testing have shown that a heat pump water heater (HPWH) uses about half the electrical energy input that an electric resistance water heater does. However, since the heat pump water heater

Oak Ridge National Laboratory

186

Electrical noise characteristics of a doped silicon microcantilever heater-thermometer  

E-Print Network [OSTI]

Electrical noise characteristics of a doped silicon microcantilever heater-thermometer Elise A with resistive heater-thermometers,10­13 there is a lack of published reports on the electrical noise silicon heater- thermometer cantilevers.12 However, a key difference is that doped silicon heater-thermometers

King, William P.

187

Solar Water Heaters and the Economy | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Water Heaters and the Economy Water Heaters and the Economy Solar Water Heaters and the Economy July 11, 2012 - 11:59am Addthis Ernie Tucker Editor, National Renewable Energy Laboratory These are the days of hot sun and mortgage refinance frenzy. Somehow, they've both combined in my mind to make me ponder the economics of a solar water heater. Because the sun's been beating down on our garden hose, the initial flush of water can be very hot. The warm spray reminded me of the times on camping trips when we'd bring along a portable solar shower -- essentially a black plastic bag with a tube and shower nozzle -- for bathing. While not an endless supply (perhaps 10 gallons), it was a very enjoyable luxury. Of course, it assumes that there's plenty of sunshine, but if so -- voila -- a warm and sudsy campsite clean-up is possible.

188

Grays Harbor PUD - Solar Water Heater Rebate | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Grays Harbor PUD - Solar Water Heater Rebate Grays Harbor PUD - Solar Water Heater Rebate Grays Harbor PUD - Solar Water Heater Rebate < Back Eligibility Commercial Industrial Residential Savings Category Heating & Cooling Solar Water Heating Program Info State District of Columbia Program Type Utility Rebate Program Rebate Amount $600 Provider Grays Harbor PUD Since October 2001, Grays Harbor PUD has offered a rebate program for the installation of solar water heaters. Rebates of $600 are available for the installation of solar collectors of 40 square feet or more. Only customers who currently use electricity for hot water are eligible. This rebate is available on a case-by-case basis, so you must contact the utility in order to take advantage of it. Customers may choose a [http://dsireusa.org/incentives/incentive.cfm?Incentive_Code=WA09F&re=1&ee=1

189

List of Water Heaters Incentives | Open Energy Information  

Open Energy Info (EERE)

Heaters Incentives Heaters Incentives Jump to: navigation, search The following contains the list of 973 Water Heaters Incentives. CSV (rows 1-500) CSV (rows 501-973) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP Ohio - Commercial New Construction Energy Efficiency Rebate Program (Ohio) Utility Rebate Program Ohio Commercial Industrial Local Government Municipal Utility Nonprofit Schools State Government Central Air conditioners Chillers Comprehensive Measures/Whole Building Custom/Others pending approval Energy Mgmt. Systems/Building Controls Heat pumps Lighting Lighting Controls/Sensors Motor VFDs Motors Water Heaters Commercial Cooking Equipment Commercial Refrigeration Equipment Room Air Conditioners Yes AEP Public Service Company of Oklahoma - Residential Efficiency Rebate Program (Oklahoma) Utility Rebate Program Oklahoma Residential Building Insulation

190

Covered Product Category: Gas Storage Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Gas Storage Water Heaters Gas Storage Water Heaters Covered Product Category: Gas Storage Water Heaters October 7, 2013 - 10:43am Addthis ENERGY STAR Qualified Products FEMP provides acquisition guidance across a variety of product categories, including gas storage water heaters, which are an ENERGY STAR®-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR. Performance Requirements for Federal Purchases For the most up-to-date efficiency levels required by ENERGY STAR, look for

191

Solar Water Heaters and the Economy | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Solar Water Heaters and the Economy Solar Water Heaters and the Economy Solar Water Heaters and the Economy July 11, 2012 - 11:59am Addthis Ernie Tucker Editor, National Renewable Energy Laboratory These are the days of hot sun and mortgage refinance frenzy. Somehow, they've both combined in my mind to make me ponder the economics of a solar water heater. Because the sun's been beating down on our garden hose, the initial flush of water can be very hot. The warm spray reminded me of the times on camping trips when we'd bring along a portable solar shower -- essentially a black plastic bag with a tube and shower nozzle -- for bathing. While not an endless supply (perhaps 10 gallons), it was a very enjoyable luxury. Of course, it assumes that there's plenty of sunshine, but if so -- voila -- a

192

Grays Harbor PUD - Solar Water Heater Loan | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Solar Water Heater Loan Solar Water Heater Loan Grays Harbor PUD - Solar Water Heater Loan < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Maximum Rebate not specified Program Info State District of Columbia Program Type Utility Loan Program Rebate Amount not specified Provider Grays Harbor PUD Since October 2001, Grays Harbor PUD has offered a low-interest loan program (currently 4.0%) for the installation of solar water heaters. Loans are available for the installation of solar collectors of 40 square feet or more. The loans are provided through local lenders, with interest subsidized by the PUD. Only customers who currently use electricity for hot water are eligible. Pre-approval is required for this loan and loan amounts are determined on a case-by-case basis.

193

New Braunfels Utilities - Residential Solar Water Heater Rebate Program |  

Broader source: Energy.gov (indexed) [DOE]

New Braunfels Utilities - Residential Solar Water Heater Rebate New Braunfels Utilities - Residential Solar Water Heater Rebate Program New Braunfels Utilities - Residential Solar Water Heater Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Program Info State Texas Program Type Utility Rebate Program Rebate Amount $0.265/kWh Provider New Braunfels Utilities New Braunfels Utilities offers a rebate for residential customers who purchase and install solar water heating systems on eligible homes. A rebate of the equivalent of $0.265 per kWh is available to these customers. The maximum rebate amount is $900 for participating customers. Applicants must have an active residential electric service account with NBU in order to be eligible. Solar water heaters must preheat water for an electric

194

Heat Recovery Consideration for Process Heaters and Boilers  

E-Print Network [OSTI]

The largest single area for industrial energy conservation is in the improvement of combustion efficiencies for heaters and boilers. A number of methods can be employed to recover heat. The most common are by use of recuperative air preheaters...

Kumar, A.

1984-01-01T23:59:59.000Z

195

Split system CO2 heat pump water heaters  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Split-system-CO2-heat-pump-water-heaters- Sign In About | Careers | Contact | Investors | bpa.gov Search Policy & Reporting Expand Policy & Reporting EE Sectors Expand EE...

196

An Analysis of Steam Process Heater Condensate Drainage Options  

E-Print Network [OSTI]

The production and reliability performance of Steam Process Heaters can be significantly affected by the condensate drainage design that is employed. There are currently a variety of drainage options which can be confusing to a system designer who...

Risko, J. R.

197

Monitoring SERC Technologies: On-Demand Tankless Water Heaters  

Broader source: Energy.gov [DOE]

A webinar by Ethan MacCormick, VP for Services to Energy Businesses at Performance Systems Development, about On-Demand Tankless Water Heaters and how to properly monitor the installation.

198

New Home Buyer Solar Water Heater Trade-Off Study  

SciTech Connect (OSTI)

This report details the results of a research conducted in 1998 and 1999 and outlines a marketing deployment plan designed for businesses interested in marketing solar water heaters in the new home industry.

Symmetrics Marketing Corporation

1999-08-18T23:59:59.000Z

199

Ninety - Two Percent Minimum Heater Efficiency By 1980  

E-Print Network [OSTI]

Technology is now available to increase heater efficiencies to 92 percent and more. By 1980, this technology will be field proven and corrosion and reliability problems identified and resolved. Recent studies have shown that a minimum efficiency...

Mieth, H. C.; Hardie, J. E.

1980-01-01T23:59:59.000Z

200

Marshall Municipal Utilities- Solar Thermal Water Heater Rebate Program  

Broader source: Energy.gov [DOE]

Marshall Municipal Utilities (MMU) offers residential customers rebates for installing a ENERGY STAR Solar Thermal Water Heater. Rebates are based on the size of the system; MMU offers $20 per...

Note: This page contains sample records for the topic "hydronic space heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Temperature limited heater utilizing non-ferromagnetic conductor  

DOE Patents [OSTI]

A heater is described. The heater includes a ferromagnetic conductor and an electrical conductor electrically coupled to the ferromagnetic conductor. The ferromagnetic conductor is positioned relative to the electrical conductor such that an electromagnetic field produced by time-varying current flow in the ferromagnetic conductor confines a majority of the flow of the electrical current to the electrical conductor at temperatures below or near a selected temperature.

Vinegar; Harold J. (Bellaire, TX), Harris; Christopher Kelvin (Houston, TX)

2012-07-17T23:59:59.000Z

202

Estimating the Cost and Energy Efficiency of a Solar Water Heater |  

Broader source: Energy.gov (indexed) [DOE]

Estimating the Cost and Energy Efficiency of a Solar Water Heater Estimating the Cost and Energy Efficiency of a Solar Water Heater Estimating the Cost and Energy Efficiency of a Solar Water Heater May 30, 2012 - 3:09pm Addthis Solar water heaters are more efficient the gas or electric heaters. | Chart credit ENERGY STAR Solar water heaters are more efficient the gas or electric heaters. | Chart credit ENERGY STAR What does this mean for me? Solar water heaters cost more to purchase and install but may save you money in the long run. Estimate the annual operating costs and compare several solar water heaters to determine whether it is worth investing in a more efficient system. Solar water heating systems usually cost more to purchase and install than conventional water heating systems. However, a solar water heater can

203

Estimating the Cost and Energy Efficiency of a Solar Water Heater |  

Broader source: Energy.gov (indexed) [DOE]

Estimating the Cost and Energy Efficiency of a Solar Water Heater Estimating the Cost and Energy Efficiency of a Solar Water Heater Estimating the Cost and Energy Efficiency of a Solar Water Heater May 30, 2012 - 3:09pm Addthis Solar water heaters are more efficient the gas or electric heaters. | Chart credit ENERGY STAR Solar water heaters are more efficient the gas or electric heaters. | Chart credit ENERGY STAR What does this mean for me? Solar water heaters cost more to purchase and install but may save you money in the long run. Estimate the annual operating costs and compare several solar water heaters to determine whether it is worth investing in a more efficient system. Solar water heating systems usually cost more to purchase and install than conventional water heating systems. However, a solar water heater can

204

Determining Benefits and Costs of Improved Water Heater Efficiencies  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Determining Benefits and Costs of Improved Water Heater Efficiencies Determining Benefits and Costs of Improved Water Heater Efficiencies Title Determining Benefits and Costs of Improved Water Heater Efficiencies Publication Type Report LBNL Report Number LBNL-45618 Year of Publication 2000 Authors Lekov, Alexander B., James D. Lutz, Xiaomin Liu, Camilla Dunham Whitehead, and James E. McMahon Document Number LBNL-45618 Date Published May 4 Abstract Economic impacts on individual consumers from possible revisions to U.S. residential water heater energy-efficiency standards are examined using a life-cycle cost (LCC) analysis. LCC is the consumer's cost of purchasing and installing a water heater and operating it over its lifetime. This approach makes it possible to evaluate the economic impacts on individual consumers from the revised standards. The methodology allows an examination of groups of the population which benefit or lose from suggested efficiency standards. The results show that the economic benefits to consumers are significant. At the efficiency level examined in this paper, 35% of households with electric water heaters experience LCC savings, with an average savings of $106, while 4% show LCC losses, with an average loss of $40 compared to a pre-standard LCC average of $2,565. The remainder of the population (61%) are largely unaffected.

205

Heat Pump Water Heater Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Water Heater Basics Water Heater Basics Heat Pump Water Heater Basics August 19, 2013 - 2:59pm Addthis Illustration of a heat pump water heater, which looks like a tall cylinder with a small chamber on top and a larger one on the bottom. In the top chamber are a fan, a cylindrical compressor, and an evaporator that runs along the inside of the chamber. Jutting out from the exterior of the bottom chamber is a temperature and pressure relief valve. This valve has a tube called a hot water outlet attached to the top. Below the valve is the upper thermostat, a small square outside the cylinder that is attached to a curved tube inside the heater. Resistance elements run from the upper thermostat to the similarly shaped lower thermostat. Below the lower thermostat is a drain valve with a cold water inlet attached to the top. Inside the cylinder is an anode, a series of thin tubes running through the bottom chamber to a coiled tube called a condenser. Insulation runs along the inside of the cylinder.

206

Performance characteristics of solar air heater with surface mounted obstacles  

Science Journals Connector (OSTI)

Abstract The performance of conventional solar air heaters (SAHs) can be improved by providing obstacles on the heated wall (i.e. on the absorber plate). Experiments have been performed to collect heat transfer and flow-friction data from an air heater duct with delta-shaped obstacles mounted on the absorber surface and having an aspect ratio 6:1 resembling the conditions close to the solar air heaters. This study encompassed for the range of Reynolds number (Re) from 2100 to 30,000, relative obstacle height (e/H) from 0.25 to 0.75, relative obstacle longitudinal pitch (Pl/e) from 3/2 to 11/2, relative obstacle transverse pitch (Pt/b) from 1 to 7/3 and the angle of incidence (?) varied from 30° to 90°. The thermo-hydraulic performance characteristics of SAH have been compared with the previous published works and the optimum range of the geometries have been explored for the better performance of such air-heaters compared to the other designs of solar air heaters.

Adisu Bekele; Manish Mishra; Sushanta Dutta

2014-01-01T23:59:59.000Z

207

Building America Whole-House Solutions for New Homes: Hydronic Heating Coil Versus Propane Furnace (Fact Sheet)  

Broader source: Energy.gov [DOE]

In this project involving two homes, the IBACOS team evaluated the performance of the two space conditioning systems and the modeled efficiency of the two tankless domestic hot water systems relative to actual occupant use.

208

SMUD - Solar Water Heater Rebate Program | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Solar Water Heater Rebate Program Solar Water Heater Rebate Program SMUD - Solar Water Heater Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Program Info State California Program Type Utility Rebate Program Rebate Amount 500 - 1,500 per system, depending on energy savings Provider Sacramento Municipal Utility District The Sacramento Municipal Utility District's (SMUD) Solar Domestic Hot Water Program provides rebates and/or loan financing to customers who install solar water heating systems. The amount of the rebate depends on how much electricity the system will offset annually: * 800 - 1,399 kWh: $500 * 1,400 - 2,199 kWh: $1,000 * 2,200 kWh or greater: $1,500 . All solar water-heating units must meet standards set by the Solar Rating

209

FEMP Designated Product Assessment for Commercial Gas Water Heaters  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

FEMP Designated Product Assessment for Commercial Gas Water Heaters FEMP Designated Product Assessment for Commercial Gas Water Heaters Title FEMP Designated Product Assessment for Commercial Gas Water Heaters Publication Type Report LBNL Report Number LBNL-5514E Year of Publication 2010 Authors Lutz, James D. Subsidiary Authors Energy Analysis Department Document Number LBNL-5514E Pagination 8 Date Published April 1 Publisher Lawrence Berkeley National Laboratory City Berkeley ISBN Number LBNL-5514E Abstract None Notes This work was supported by the Assistant Secretary for Energy Efficiency and Renewable Energy, Office of Building Technology, State, and Community Programs, of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231. Attachment Size PDF 240.22 KB Google Scholar BibTex RIS RTF XML Alternate URL: http://eetd.lbl.gov/node/50317

210

Savings Project: Insulate Your Water Heater Tank | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Savings Project: Insulate Your Water Heater Tank Savings Project: Insulate Your Water Heater Tank Savings Project: Insulate Your Water Heater Tank Addthis Project Level medium Energy Savings $20-$45 annually Time to Complete 1.5 hours Overall Cost $30 Insulate your hot water tank to save energy and money. | Photo courtesy of iStockphoto.com/glennebo Insulate your hot water tank to save energy and money. | Photo courtesy of iStockphoto.com/glennebo Just like insulating your walls or roof, insulating your hot water tank is an easy and inexpensive way to improve energy efficiency and save you money each month. If your water tank is new, it is likely already insulated. If you have an older hot water tank, check to see if it has insulation with an R-value of at least 24. If not, consider insulating your water tank, which

211

Experimental study of integrated collector storage solar water heaters  

Science Journals Connector (OSTI)

Three Integrated Collector Storage Solar Water Heaters (ICSSWH) have been designed, constructed and experimentally studied in comparison to a Flat Plate Thermosiphonic Unit (FPTU). Each of the ICS experimental models consists of one cylindrical tank horizontally mounted in a stationary symmetrical Compound Parabolic Concentrating (CPC) reflector trough. The main objective is the design and construction of low cost solar water heaters with improved thermal performance and lower possible depths. The experimental models can be mounted on horizontal as well as on inclined roofs by adopting the lowest possible depth. The results show that these solar devices perform more than effectively all year long. This could contribute significantly on the development of ICS type solar water heaters.

M. Souliotis; D. Chemisana; Y.G. Caouris; Y. Tripanagnostopoulos

2013-01-01T23:59:59.000Z

212

Outdoor Outfitter Gets Greener With Solar Water Heater | Department of  

Broader source: Energy.gov (indexed) [DOE]

Outdoor Outfitter Gets Greener With Solar Water Heater Outdoor Outfitter Gets Greener With Solar Water Heater Outdoor Outfitter Gets Greener With Solar Water Heater October 8, 2010 - 12:51pm Addthis L.L. Bean’s flagship store sees nearly 3 million visitors each year. The store now uses solar-heated water for showers, restrooms and two cafes. | Photo courtesy of L.L. Bean | L.L. Bean's flagship store sees nearly 3 million visitors each year. The store now uses solar-heated water for showers, restrooms and two cafes. | Photo courtesy of L.L. Bean | Lindsay Gsell L.L. Bean is known for its outdoor apparel- jackets, backpacks and cozy winter sweaters. However, the company does more than just dress for the outdoors, it also works to protect and preserve it. For nearly 100 years, L.L. Bean has been committed to environmental conservation and

213

Feedback regulated induction heater for a flowing fluid  

DOE Patents [OSTI]

A regulated induction heater for heating a stream of flowing fluid to a predetermined desired temperature. The heater includes a radiofrequency induction coil which surrounds a glass tube through which the fluid flows. A heating element consisting of a bundle of approximately 200 stainless steel capillary tubes located within the glass tube couples the output of the induction coil to the fluid. The temperature of the fluid downstream from the heating element is sensed with a platinum resistance thermometer, the output of which is applied to an adjustable porportional and integral feedback control circuit which regulates the power applied to the induction coil. The heater regulates the fluid temperature to within 0.005/sup 0/C at a flow rate of 50 cm/sup 3//sec with a response time of less than 0.1 second, and can accommodate changes in heat load up to 1500 watts.

Migliori, A.; Swift, G.W.

1984-06-13T23:59:59.000Z

214

Feedback regulated induction heater for a flowing fluid  

DOE Patents [OSTI]

A regulated induction heater for heating a stream of flowing fluid to a predetermined desired temperature. The heater includes a radiofrequency induction coil which surrounds a glass tube through which the fluid flows. A heating element consisting of a bundle of approximately 200 stainless steel capillary tubes located within the glass tube couples the output of the induction coil to the fluid. The temperature of the fluid downstream from the heating element is sensed with a platinum resistance thermometer, the output of which is applied to an adjustable proportional and integral feedback control circuit which regulates the power applied to the induction coil. The heater regulates the fluid temperature to within 0.005.degree. C. at a flow rate of 50 cm.sup.3 /second with a response time of less than 0.1 second, and can accommodate changes in heat load up to 1500 watts.

Migliori, Albert (Santa Fe, NM); Swift, Gregory W. (Los Alamos, NM)

1985-01-01T23:59:59.000Z

215

Our Environment in Hot Water: Comparing Water Heaters, A Life Cycle Approach Comparing Tank and Tankless Water Heaters in California  

SciTech Connect (OSTI)

Residential water heating is a large source of energy use in California homes. This project took a life cycle approach to comparing tank and tankless water heaters in Northern and Southern California. Information about the life cycle phases was calculated using the European Union?s Methodology study for EcoDesign of Energy-using Products (MEEUP) and the National Renewable Energy Laboratory?s Life Cycle Inventory (NREL LCI) database. In a unit-to-unit comparison, it was found that tankless water heaters would lessen impacts of water heating by reducing annual energy use by 2800 MJ/year (16% compared to tank), and reducing global warming emissions by 175 kg CO2 eqv./year (18% reduction). Overall, the production and combustion of natural gas in the use phase had the largest impact. Total waste, VOCs, PAHs, particulate matter, and heavy-metals-to-air categories were also affected relatively strongly by manufacturing processes. It was estimated that tankless water heater users would have to use 10 more gallons of hot water a day (an increased usage of approximately 20%) to have the same impact as tank water heaters. The project results suggest that if a higher percentage of Californians used tankless water heaters, environmental impacts caused by water heating would be smaller.

Lu, Alison; McMahon, James; Masanet, Eric; Lutz, Jim

2008-08-13T23:59:59.000Z

216

HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review ...  

Energy Savers [EERE]

HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review Presenter: Tony Bouza, U.S. Department of Energy This...

217

Numerical analysis of thermal-hydrological conditions in the single heater test at Yucca Mountain  

E-Print Network [OSTI]

Single Heater Test at Yucca Mountain, LBNL-39789, E.O. Law­Single Heater Test at Yucca Mountain Jens T. Birkholzer andwaste repository at Yucca Mountain. The heating phase of the

Birkholzer, Jens T.; Tsang, Yvonne W.

1998-01-01T23:59:59.000Z

218

NREL Develops Heat Pump Water Heater Simulation Model (Fact Sheet), NREL Highlights, Research & Development, NREL (National Renewable Energy Laboratory)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

simulation model helps researchers evaluate real-world simulation model helps researchers evaluate real-world impacts of heat pump water heaters in U.S. homes. Heat pump water heaters (HPWHs) remove heat from the air and use it to heat water, presenting an energy-saving opportunity for homeowners. Researchers at the National Renewable Energy Laboratory (NREL) developed a simulation model to study the inter- actions of HPWHs and space conditioning equipment, related to climate and installa- tion location in the home. This model was created in TRNSYS and is based on data from HPWHs tested at NREL's Advanced HVAC Systems Laboratory. The HPWH model accounts for the condenser coil wrapped around the outside of the storage tank, and uses a data-based performance map. Researchers found that simulated energy use was within 2% of lab results, which confirms

219

Modeling and Test-and-Rate Methods for Innovative Thermosiphon Solar Water Heaters: Preprint  

SciTech Connect (OSTI)

Conference paper regarding research in modeling and test-and-rate methods for thermosiphon solar domestic water heaters.

Burch, J.; Shoukas, G.; Brandemuhl, M.; Krarti, M.

2006-05-01T23:59:59.000Z

220

Field Testing of Pre-Production Prototype Residential Heat Pump Water Heaters  

Broader source: Energy.gov [DOE]

Provides and overview of field testing of 18 pre-production prototype residential heat pump water heaters

Note: This page contains sample records for the topic "hydronic space heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Conventional Storage Water Heater Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Conventional Storage Water Heater Basics Conventional Storage Water Heater Basics Conventional Storage Water Heater Basics July 30, 2013 - 3:39pm Addthis Illustration showing the components of a storage water heater. On top of the tank are two thin pipes; one pipe is the hot water outlet, and the other is the cold water inlet. A large pipe in the middle is called a vent pipe. A pressure/temperature relief valve is also on top of the tank and is connected to an open pipe that runs down the side of the tank. Another valve near the bottom of the outside of the tank is the thermostat and gas valve. A cutout shows the parts inside the tank, which include a large tube called a flue tube/heat exchanger. Inside this tube is a jagged insert called a flue baffle. Beside the flue tube/heat exchanger is a thin tube called the anode rod. At the bottom of the tank is a gas burner, and beneath the burner are combustion air openings.

222

Silicon microbench heater elements for packaging opto-electronic devices  

SciTech Connect (OSTI)

Examples are presented of the application of Lawrence Livermore National Laboratory`s expertise in photonics packaging. Several examples of packaged devices will be described. Particular attention is given to silicon microbenches incorporating heaters and their use in semiconductor optical amplifier fiber pigtailing and packaging.

Combs, R.; Keiser, P.; Kleint, K.; Pocha, M.; Patterson, F.; Strand, O.T.

1995-09-01T23:59:59.000Z

223

Covered Product Category: Residential Heat Pump Water Heaters  

Broader source: Energy.gov [DOE]

FEMP provides acquisition guidance and Federal efficiency requirements across a variety of product categories, including residential heat pump water heaters, which are an ENERGY STAR®-qualified product category. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

224

Covered Product Category: Residential Electric Resistance Water Heaters  

Broader source: Energy.gov [DOE]

FEMP sets Federal efficiency requirements and provides acquisition guidance across a variety of product categories, including residential electric resistance water heaters. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

225

Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters  

SciTech Connect (OSTI)

This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of US climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt(tm) whole-house building simulations.

Sparn, B.; Hudon, K.; Christensen, D.

2014-06-01T23:59:59.000Z

226

Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters  

SciTech Connect (OSTI)

This report discusses how a significant opportunity for energy savings is domestic hot water heating, where an emerging technology has recently arrived in the U.S. market: the residential integrated heat pump water heater. A laboratory evaluation is presented of the five integrated HPWHs available in the U.S. today.

Sparn, B.; Hudon, K.; Christensen, D.

2011-09-01T23:59:59.000Z

227

Covered Product Category: Residential Gas Storage Water Heaters  

Broader source: Energy.gov [DOE]

FEMP provides acquisition guidance across a variety of product categories, including gas storage water heaters, which are an ENERGY STAR®-qualified product category. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

228

Novel Column Heater for Fast Capillary Gas Chromatography  

Science Journals Connector (OSTI)

......expected advantage of radial heating with the coaxial heater...with other "coated" heating elements, differences...Louisiana light crude oil; 3 m 0.1 mm phenyl...expansion coefficient, and price imposed substantial practical...existing standard column heating technology. Thus, chromatographic......

E.U. Ehrmann; H.P. Dharmasena; K. Carney; E.B. Overton

1996-12-01T23:59:59.000Z

229

Restoration of Refinery Heaters Using the Technique of Prefabricated Ceramic Fiber Lined Panels  

E-Print Network [OSTI]

Refinery heater fuel requirements often represent 50% of a units operating cost. A one percent change in the efficiency of a heater firing 100 MBtu/hr amounts to more than $25,000 per year. Heater efficiency is influenced by casing hot spots, air...

Sento, H. D.

1981-01-01T23:59:59.000Z

230

Development of a Market Optimized Condensing Gas Water Heater  

SciTech Connect (OSTI)

This program covered the development of a market optimized condensing gas water heater for residential applications. The intent of the program was to develop a condensing design that minimized the large initial cost premium associated with traditional condensing water heater designs. Equally important was that the considered approach utilizes design and construction methods that deliver the desired efficiency without compromising product reliability. Standard condensing water heater approaches in the marketplace utilize high cost materials such as stainless steel tanks and heat exchangers as well as expensive burner systems to achieve the higher efficiencies. The key in this program was to develop a water heater design that uses low-cost, available components and technologies to achieve higher efficiency at a modest cost premium. By doing this, the design can reduce the payback to a more reasonable length, increasing the appeal of the product to the marketplace. Condensing water heaters have been in existence for years, but have not been able to significantly penetrate the market. The issue has typically been cost. The high purchase price associated with existing condensing water heaters, sometimes as much as $2000, has been a very difficult hurdle to overcome in the marketplace. The design developed under this program has the potential to reduce the purchase price of this condensing design by as much as $1000 as compared to traditional condensing units. The condensing water heater design developed over the course of this program led to an approach that delivered the following performance attributes: 90%+ thermal efficiency; 76,000 Btu/hr input rate in a 50 gallon tank; First hour rating greater than 180 gph; Rapid recovery time; and Overall operating condition well matched to combination heat and hot water applications. Over the final three years of the program, TIAX worked very closely with A.O. Smith Water Products Company as our commercial partner to optimize the design for manufacturing. This work included the initiation of a large field testing program (over 125 units) and an in-depth reliability program intended to minimize the risks associated with a new product introduction. At the time of this report, A.O. Smith plans to introduce this product to the marketplace in the early 2006 time period.

Peter Pescatore

2006-01-11T23:59:59.000Z

231

Cascade Natural Gas - Conservation Incentives for New Homes | Department of  

Broader source: Energy.gov (indexed) [DOE]

Cascade Natural Gas - Conservation Incentives for New Homes Cascade Natural Gas - Conservation Incentives for New Homes Cascade Natural Gas - Conservation Incentives for New Homes < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Construction Commercial Heating & Cooling Design & Remodeling Sealing Your Home Ventilation Heating Appliances & Electronics Water Heating Program Info State District of Columbia Program Type Utility Rebate Program Rebate Amount High Efficiency Natural Gas Furnace: $150 High Efficiency Natural Gas Hearth: $70 Conventional Natural Gas Water Heater: $40 Condensing Tankless Water Heater: $200 Combined Domestic Water/Hydronic Space Heating System (usingTankless Water Heater): $800 Energy Star Certified Home: $350 Energy Star Certified Plus Home: $750

232

Impact of Pilot Light Modeling on the Predicted Annual Performance of Residential Gas Water Heaters: Preprint  

SciTech Connect (OSTI)

Modeling residential water heaters with dynamic simulation models can provide accurate estimates of their annual energy consumption, if the units? characteristics and use conditions are known. Most gas storage water heaters (GSWHs) include a standing pilot light. It is generally assumed that the pilot light energy will help make up standby losses and have no impact on the predicted annual energy consumption. However, that is not always the case. The gas input rate and conversion efficiency of a pilot light for a GSWH were determined from laboratory data. The data were used in simulations of a typical GSWH with and without a pilot light, for two cases: 1) the GSWH is used alone; and 2) the GSWH is the second tank in a solar water heating (SWH) system. The sensitivity of wasted pilot light energy to annual hot water use, climate, and installation location was examined. The GSWH used alone in unconditioned space in a hot climate had a slight increase in energy consumption. The GSWH with a pilot light used as a backup to an SWH used up to 80% more auxiliary energy than one without in hot, sunny locations, from increased tank losses.

Maguire, J.; Burch, J.

2013-08-01T23:59:59.000Z

233

Placing technology : examining the emerging use of solar water heaters in Oaxaca, Mexico: Examining the emerging use of solar water heaters in Oaxaca, Mexico.  

E-Print Network [OSTI]

??This study is an examination of the (broadly envisioned) process that has led to the emerging use of solar water heaters in Oaxaca de Jua?rez,… (more)

Shannon, Steven Jacob

2011-01-01T23:59:59.000Z

234

Three-phase heaters with common overburden sections for heating subsurface formations  

DOE Patents [OSTI]

A heating system for a subsurface formation is described. The heating system includes three substantially u-shaped heaters with first end portions of the heaters being electrically coupled to a single, three-phase wye transformer and second end portions of the heaters being electrically coupled to each other and/or to ground. The three heaters may enter the formation through a first common wellbore and exit the formation through a second common wellbore so that the magnetic fields of the three heaters at least partially cancel out in the common wellbores.

Vinegar, Harold J. (Bellaire, TX)

2012-02-14T23:59:59.000Z

235

Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Carbon Dioxide-Based Carbon Dioxide-Based Heat Pump Water Heater Research Project to someone by E-mail Share Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater Research Project on Facebook Tweet about Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater Research Project on Twitter Bookmark Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater Research Project on Google Bookmark Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater Research Project on Delicious Rank Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater Research Project on Digg Find More places to share Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater Research Project on AddThis.com...

236

Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Gas-Fired Absorption Gas-Fired Absorption Heat Pump Water Heater Research Project to someone by E-mail Share Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on Facebook Tweet about Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on Twitter Bookmark Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on Google Bookmark Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on Delicious Rank Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on Digg Find More places to share Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on AddThis.com...

237

Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Performance Performance Evaluation of Residential Integrated Heat Pump Water Heaters B. Sparn, K. Hudon, and D. Christensen Technical Report NREL/TP-5500-52635 September 2011 NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency & Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. National Renewable Energy Laboratory 1617 Cole Boulevard Golden, Colorado 80401 303-275-3000 * www.nrel.gov Contract No. DE-AC36-08GO28308 Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters B. Sparn, K. Hudon, and D. Christensen Prepared under Task Nos. WTN9.1000, ARRB.2204 Technical Report NREL/TP-5500-52635 September 2011 NOTICE This report was prepared as an account of work sponsored by an agency of the United States government.

238

Variably insulating portable heater/cooler  

DOE Patents [OSTI]

A compact vacuum insulation panel comprising a chamber enclosed by two sheets of metal, glass-like spaces disposed in the chamber between the sidewalls, and a high-grade vacuum in the chamber includes apparatus and methods for enabling and disabling, or turning "on" and "off" the thermal insulating capability of the panel. One type of enabling and disabling apparatus and method includes a metal hydride for releasing hydrogen gas into the chamber in response to heat, and a hydrogen grate between the metal hydride and the chamber for selectively preventing and allowing return of the hydrogen gas to the metal hydride. Another type of enabling and disabling apparatus and method includes a variable emissivity coating on the sheets of metal in which the emissivity is controllably variable by heat or electricity. Still another type of enabling and disabling apparatus and method includes metal-to-metal contact devices that can be actuated to establish or break metal-to-metal heat paths or thermal short circuits between the metal sidewalls.

Potter, Thomas F. (Denver, CO)

1998-01-01T23:59:59.000Z

239

Variably insulating portable heater/cooler  

DOE Patents [OSTI]

A compact vacuum insulation panel is described comprising a chamber enclosed by two sheets of metal, glass-like spaces disposed in the chamber between the sidewalls, and a high-grade vacuum in the chamber includes apparatus and methods for enabling and disabling, or turning ``on`` and ``off`` the thermal insulating capability of the panel. One type of enabling and disabling apparatus and method includes a metal hydride for releasing hydrogen gas into the chamber in response to heat, and a hydrogen grate between the metal hydride and the chamber for selectively preventing and allowing return of the hydrogen gas to the metal hydride. Another type of enabling and disabling apparatus and method includes a variable emissivity coating on the sheets of metal in which the emissivity is controllably variable by heat or electricity. Still another type of enabling and disabling apparatus and method includes metal-to-metal contact devices that can be actuated to establish or break metal-to-metal heat paths or thermal short circuits between the metal sidewalls. 25 figs.

Potter, T.F.

1998-09-29T23:59:59.000Z

240

Advances in the Research of Heat Pump Water Heaters  

E-Print Network [OSTI]

ICEBO2006, Shenzhen, China Renewable Energy Resources and a Greener Future Vol.VIII-12-2 1 Advances in the Research of Heat Pump Water Heaters Shangli Shan Dandan Wang Ruixiang Wang Master Master Professor Beijing...) [21] Wang sui-lin . Affection on fin-and-tube Heat Exchanger's Properties by non azeotropic mixtures[J] . Fluid machinery , 1996 , 24 (5) [22] Ge run-ting . Foundation of Dynamic Parameter Model and Theoritical Calculation of Evaporator...

Shan, S.; Wang, D.; Wang, R.

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hydronic space heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

U. K. consortium Stirling engine regenerator effectiveness and heater performance  

SciTech Connect (OSTI)

This paper covers results of measurements of effectiveness of regenerator materials by use of a dynamic test rig. The rig enables measurements to be made of enthalpy flux through the regenerator under simulated Stirling engine conditions of fluid flow and heat transfer. The paper also discusses the design and operation of the 60 kw heat-pipe heater head of the U.K. Consortium Stirling engine.

Rice, G.; Dadd, M.W.; Jones, J.D.; Thonger, J.

1983-08-01T23:59:59.000Z

242

Chiller-heater unit nets building 2-yr payback  

SciTech Connect (OSTI)

A 500-ton double-absorption Hitachi Paraflow chiller-heater that switches from purchased steam to natural gas will reduce a Manhattan office building's energy costs by 55% and achieve a two-year payback. The new system replaces a steam-powered, single-stage absorption chiller. By reusing heat in a second-stage generator, the Hitachi unit uses only half as many Btus per ton as a conventional chiller. (DCK)

Duffy, J.

1983-05-09T23:59:59.000Z

243

Materials performance in fluidized-bed air heaters  

SciTech Connect (OSTI)

Development of cogeneration systems that involve combustion of coal in a fluidized bed and use of air heaters to generate hot air for turbine systems has been in progress for a number of years. The US Department of Energy (DOE) sponsored the Atmospheric Fluidized-Bed Cogeneration Air Heater Experiment (ACAHE) to assess the performance of various heat exchanger materials and establish confidence in the resultant designs of fluidized-bed-combustion air heater systems. Westinghouse Electric Corporation, in association with Babcock & Wilcox, Foster Wheeler, and ABB/Combustion Engineering, prepared specifications and hardware for the ACAHE. Argonne National Laboratory, through a contract with the Rocketdyne Division of Rockwell International, conducted tests in the DOE 1.8 {times} 1.8 m atmospheric fluidized-bed combustion facility in El Segundo, California. This paper presents an assessment of the materials performance in fluidized bed environments and examines guidelines for materials selection on the basis of corrosion resistance in air and in combustion environments, mechanical properties, fabricability/thermal stability, and cost.

Natesan, K.; Podolski, W.

1991-12-01T23:59:59.000Z

244

Materials performance in fluidized-bed air heaters  

SciTech Connect (OSTI)

Development of cogeneration systems that involve combustion of coal in a fluidized bed and use of air heaters to generate hot air for turbine systems has been in progress for a number of years. The US Department of Energy (DOE) sponsored the Atmospheric Fluidized-Bed Cogeneration Air Heater Experiment (ACAHE) to assess the performance of various heat exchanger materials and establish confidence in the resultant designs of fluidized-bed-combustion air heater systems. Westinghouse Electric Corporation, in association with Babcock Wilcox, Foster Wheeler, and ABB/Combustion Engineering, prepared specifications and hardware for the ACAHE. Argonne National Laboratory, through a contract with the Rocketdyne Division of Rockwell International, conducted tests in the DOE 1.8 {times} 1.8 m atmospheric fluidized-bed combustion facility in El Segundo, California. This paper presents an assessment of the materials performance in fluidized bed environments and examines guidelines for materials selection on the basis of corrosion resistance in air and in combustion environments, mechanical properties, fabricability/thermal stability, and cost.

Natesan, K.; Podolski, W.

1991-12-01T23:59:59.000Z

245

Electric Water Heater Modeling and Control Strategies for Demand Response  

SciTech Connect (OSTI)

Abstract— Demand response (DR) has a great potential to provide balancing services at normal operating conditions and emergency support when a power system is subject to disturbances. Effective control strategies can significantly relieve the balancing burden of conventional generators and reduce investment on generation and transmission expansion. This paper is aimed at modeling electric water heaters (EWH) in households and tests their response to control strategies to implement DR. The open-loop response of EWH to a centralized signal is studied by adjusting temperature settings to provide regulation services; and two types of decentralized controllers are tested to provide frequency support following generator trips. EWH models are included in a simulation platform in DIgSILENT to perform electromechanical simulation, which contains 147 households in a distribution feeder. Simulation results show the dependence of EWH response on water heater usage . These results provide insight suggestions on the need of control strategies to achieve better performance for demand response implementation. Index Terms— Centralized control, decentralized control, demand response, electrical water heater, smart grid

Diao, Ruisheng; Lu, Shuai; Elizondo, Marcelo A.; Mayhorn, Ebony T.; Zhang, Yu; Samaan, Nader A.

2012-07-22T23:59:59.000Z

246

Testing and analysis of the Semiscale Mod-1 heater rod design  

SciTech Connect (OSTI)

The use of electrically heated nuclear fuel rod simulators in the Semiscale Program is traced from a historical viewpoint. The design of the Semiscale Mod-1 electrical heater rod and core simulator is discussed. Heater rod thermal response during transient thermal-hydraulic depressurization experiments conducted in the Mod-1 system, and analysis techniques and tests conducted to help quantify heater rod characteristics and behavior are presented.

Larson, T.K.

1980-01-01T23:59:59.000Z

247

HEATER TEST PLANNING FOR THE NEAR SURFACE TEST FACILITY AT THE HANFORD RESERVATION  

E-Print Network [OSTI]

Heater Experiment at Hanford. Berkeley, Lawre ;e BerkeleyTest Facility, Hole DC-11, Hanford Reservation. Prepared forof Gable Mountain Basalt Cores, Hanford Nuclear Reservation.

DuBois, A.

2010-01-01T23:59:59.000Z

248

Development of solar air heaters & thermal energy storage system for drying applications in food processing industries.  

E-Print Network [OSTI]

??In the present work, the author has designed and developed all types of solar air heaters called porous and nonporous collectors. The developed solar air… (more)

Sreekumar, A

2007-01-01T23:59:59.000Z

249

DOE Publishes Notice of Proposed Rulemaking for Direct Heating Equipment and Pool Heater Test Procedures  

Broader source: Energy.gov [DOE]

The Department of Energy has published a notice of proposed rulemaking regarding test procedures for direct heating equipment and pool heaters.

250

Sustainable Energy Resources for Consumers (SERC)- On-Demand Tankless Water Heaters  

Broader source: Energy.gov [DOE]

This presentation, aimed at Sustainable Energy Resources for Consumers (SERC) grantees, provides information on Monitoring Checklists for the installation of On-Demand Tankless Water Heaters.

251

A model for improvement of water heating heat exchanger designs for residential heat pump water heaters.  

E-Print Network [OSTI]

??Heat pump water heaters are a promising technology to reduce energy use and greenhouse gas emissions. A key component is the water heating heat exchanger.… (more)

Weerawoot, Arunwattana

2010-01-01T23:59:59.000Z

252

An Evaluation of the Water Heater Load Potential for Providing Regulation Service  

SciTech Connect (OSTI)

This paper investigates the possibility of providing aggregated regulation services with small loads, such as water heaters or air conditioners. A direct-load control algorithm is presented to aggregate the water heater load for the purpose of regulation. A dual-element electric water heater model is developed, which accounts for both thermal dynamics and users’ water consumptions. A realistic regulation signal was used to evaluate the number of water heaters needed and the operational characteristics of a water heater when providing 2-MW regulation service. Modeling results suggest that approximately 33,333 water heaters are needed to provide a 2-MW regulation service 24 hours a day. However, if water heaters only provide regulation from 6:00 to 24:00, approximately 20,000 will be needed. Because the control algorithm has considered the thermal setting of the water heater, the customer comfort is obstructed little. Therefore, the aggregated regulation service provided by water heater loads can become a major source of revenue for load-service entities when the smart grid enables the direct load control.

Kondoh, Junji; Lu, Ning; Hammerstrom, Donald J.

2011-08-31T23:59:59.000Z

253

Annual Operating Characteristics of Solar Central Water Heater System Assisted by Heat Pump  

Science Journals Connector (OSTI)

The solar central water heater (SCWH) could supply ... massive users effectively and reliably. A SCWH assisted by heat pump (SCWHP) was proposed...

Wei Hu; Zhaolin Gu; Shiyu Feng; Xiufeng Gao…

2009-01-01T23:59:59.000Z

254

Solar Hot Water Heater Augmented with PV-TEM Heat Pump.  

E-Print Network [OSTI]

??Solar assisted heat pumps (SAHPs) can provide higher collector efficiencies and solar fractions when compared against standard solar hot water heaters. Vapour compression (VC) heat… (more)

PRESTON, NATHANIEL

255

Energy Efficiency Design Options for Residential Water Heaters: Economic Impacts on Consumers  

E-Print Network [OSTI]

as conventional electric resistance water heaters. Atwo technologies: (1) an electric resistance storage waterin heat pump or in electric resistance mode. The electric

Lekov, Alex

2011-01-01T23:59:59.000Z

256

Economic Analysis of Solar Water Heaters in GuangZhou  

E-Print Network [OSTI]

ICEBO2006, Shenzhen, China Policy for Energy Efficiency and Comfort, Vol.VII-4-4 Economic Analysis of Solar Water Heaters in GuangZhou Ying Wang LiHua Zhao Graduated Student Associate Professor School of Architecture, South China... and lasting from a social benefit point of view in order to sustainable develop and ICEBO2006, Shenzhen, China Policy for Energy Efficiency and Comfort, Vol.VII-4-4 benefit our offspring. REFERENCES [1] Yi Yun, ShanMing Wang. Market insight of solar...

Wang, Y.; Zhao, L.

2006-01-01T23:59:59.000Z

257

Eleana near-surface heater experiment final report  

SciTech Connect (OSTI)

This report summarizes the results of a near-surface heater experiment operated at a depth of 23 m in argillite within the Eleana Formation on the Nevada Test Site (NTS). The test geometrically simulated emplacement of a single canister of High-Level Waste (HLW) and was operated at a power level of 2.5 kW for 21 days, followed by 3.8 kW to 250 days, when the power was turned off. Below 85 to 100{sup 0}C, there was good agreement between modeled and measured thermal results in the rock and in the emplacement hole, except for transient transport of water in the heater hole. Above 100{sup 0}C, modeled and measured thermal results increasingly diverged, indicating that the in-situ rock-mass thermal conductivity decreased as a result of dehydration more than expected on the basis of matrix properties. Correlation of thermomechanical modeling and field results suggests that this decrease was caused by strong coupling of thermal and mechanical behavior of the argillite at elevated temperatures. No hole-wall decrepitation was observed in the experiment; this fact and the codrrelation of modeled and measured results at lower temperatures indicate that there is no a priori reason to eliminate argillaceous rocks from further consideration as a host rock for nuclear wastes.

Lappin, A R; Thomas, R K; McVey, D F

1981-04-01T23:59:59.000Z

258

Energy Cost Calculator for Electric and Gas Water Heaters | Department of  

Broader source: Energy.gov (indexed) [DOE]

Electric and Gas Water Heaters Electric and Gas Water Heaters Energy Cost Calculator for Electric and Gas Water Heaters October 8, 2013 - 2:26pm Addthis Vary equipment size, energy cost, hours of operation, and /or efficiency level. INPUT SECTION Input the following data (if any parameter is missing, calculator will set to default value). Defaults Type of Water Heater Electric Gas Electric Average Daily Usage (gallons per day)* gallons 64* Energy Factor† 0.92 (electric) 0.61 (gas) Energy Cost $ / kWh $0.06 per kWh $.60 per therm Quantity of Water Heaters to be Purchased unit(s) 1 unit * See assumptions for various daily water use totals. † The comparison assumes a storage tank water heater as the input type. To allow demand water heaters as the comparison type, users can specify an input EF of up to 0.85; however, 0.66 is currently the best available EF for storage water heaters.

259

Selecting a New Water Heater You have a lot to consider when selecting a  

E-Print Network [OSTI]

the water heater's annual operation costs but also its size and energy efficiency. Natural gas, oil or tank water heater operates by releasing hot water from the top of the tank when the hot water tap is turned on. The hot water is released into the hot water line. As the hot water leaves the tank, cold

260

PRELIMINARY THERMAL AND THERMOMECH-ANICAL MODELING FOR THE NEAR SURFACE TEST FACILITY HEATER EXPERIMANTS AT HANFORD: Appendix D  

E-Print Network [OSTI]

Heater Experiments at Hanford V O L U M E II (Appendix D) TENG-48 and for Rockwell Hanford Operations — a Department ofFACILITY HEATER EXPERIMENTS AT HANFORD Volume 2 (Appendix D)

Chan, T.

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hydronic space heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Spatially resolved temperature and heat flux measurements for slow evaporating droplets heated by a microfabricated heater array  

E-Print Network [OSTI]

The evaporation phenomenon of a liquid droplet was investigated by using microfabricated heaters. All 32 microheaters were designed to have the same resistance. Gold microheaters worked both as temperature indicators and as heaters. The first...

Paik, Sokwon

2006-08-16T23:59:59.000Z

262

Building America Top Innovations Hall of Fame Profile … Tankless Gas Water Heater Performance  

Broader source: Energy.gov (indexed) [DOE]

Incorporating tankless water heaters was one Incorporating tankless water heaters was one of many energy-efficiency recommendations Building America's research team IBACOS had for San Antonio builder Imagine Homes. Although tankless gas water heaters should save approximately 33% on hot water heating compared to a conventional storage water heater, actual energy savings vary significantly based on individual draw volume. Above 10 gallons per draw, the efficiency approaches the rated energy factor. The greatest savings occur at a daily use quantity of about 50 gallons. BUILDING AMERICA TOP INNOVATIONS HALL OF FAME PROFILE INNOVATIONS CATEGORY: 1. Advanced Technologies and Practices 1.2 Energy Efficient Components Tankless Gas Water Heater Performance As improved thermal enclosures dramatically reduce heating and cooling loads,

263

Enhancement of Heat Transfer in an Artificially Roughened Solar Air Heater  

E-Print Network [OSTI]

Abstract: solar air heater is one of the basic equipment through which solar energy is converted into thermal energy. Solar air heaters, because of their simple in design, are cheap and most widely used collection devices of solar energy. The thermal efficiency of a solar air heater is significantly low because of the low value of the convective heat transfer coefficient between the absorber plate and the air, leading to high absorber plate temperature and high heat losses to the surroundings. This paper presents the study of heat transfer in a solar air heater by using Computational Fluid Dynamics (CFD). The effect of Reynolds number on Nusselt number is investigated. A commercial finite volume package ANSYS FLUENT 12.1 is used to analyze and visualize the nature of the flow across the duct of a solar air heater.

unknown authors

264

Gas-Fired Absorption Heat Pump Water Heater Research Project | Department  

Broader source: Energy.gov (indexed) [DOE]

Emerging Technologies » Gas-Fired Absorption Heat Pump Water Emerging Technologies » Gas-Fired Absorption Heat Pump Water Heater Research Project Gas-Fired Absorption Heat Pump Water Heater Research Project The U.S. Department of Energy (DOE) is currently conducting research into carbon gas-fired absorption heat pump water heaters. This project will employ innovative techniques to increase water heating energy efficiency over conventional gas storage water heaters by 40%. Project Description This project seeks to develop a natural gas-fired water heater using an absorption heat. The development effort is targeting lithium bromide aqueous solutions as a working fluid in order to avoid the negative implications of using more toxic ammonia. Project Partners Research is being undertaken through a Cooperative Research and Development

265

Indoor air pollutants from unvented kerosene heater emissions in mobile homes: studies on particles, semivolatile organics, carbon monoxide, and mutagenicity  

Science Journals Connector (OSTI)

Indoor air pollutants from unvented kerosene heater emissions in mobile homes: studies on particles, semivolatile organics, carbon monoxide, and mutagenicity ...

Judy L. Mumford; Ron W. Williams; Debra B. Walsh; Robert M. Burton; David J. Svendsgaard; Jane C. Chuang; Virginia S. Houk; Joellen Lewtas

1991-10-01T23:59:59.000Z

266

Combination fence and solar heater for swimming pools  

SciTech Connect (OSTI)

A combination fence and solar heater for swimming pools comprises a fence shaped for extending about the periphery of the pool to restrict ingress and egress therefrom. A tubular heat exchanger is formed in at least one section of the fence, includes an exterior surface adapted to absorb solar energy, and communicates with the water in the swimming pool. The number of heat exchanger fence sections can be varied in accordance with the climate in which the pool is located. A pump flows the water in the swimming pool through the heat exchanger fence sections during daylight hours, thereby simultaneously heating the water in the pool, and providing an attractive and protective safety barrier about the swimming pool.

Divine, D.L.

1981-07-28T23:59:59.000Z

267

Evaluation of a Stirling engine heater bypass with the NASA Lewis nodal-analysis performance code  

SciTech Connect (OSTI)

In support of the US Department of Energy's Stirling Engine Highway Vehicle Systems program, the NASA Lewis Research Center investigated whether bypassing the P-40 Stirling engine heater during regenerative cooling would improve the engine thermal efficiency. The investigation was accomplished by using the Lewis nodal-analysis Stirling engine computer model. Bypassing the P-40 Stirling engine heater at full power resulted in a rise in the indicated thermal efficiency from 40.6 to 41.0 percent. For the idealized (some losses not included) heater bypass that was analyzed, this benefit is not considered significant.

Sullivan, T.J.

1986-05-01T23:59:59.000Z

268

Economics of Residential Gas Furnaces and Water Heaters in United States  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Economics of Residential Gas Furnaces and Water Heaters in United States Economics of Residential Gas Furnaces and Water Heaters in United States New Construction Market Speaker(s): Alex Lekov Gabrielle Wong-Parodi James McMahon Victor Franco Date: May 8, 2009 - 12:00pm Location: 90-3122 In the new single-family home construction market, the choice of what gas furnace and gas water heater combination to install is primarily driven by first cost considerations. In this study, the authors use a life-cycle cost analysis approach that accounts for uncertainty and variability of inputs to assess the economic benefits of installing different gas furnace and water heater combinations. Among other factors, it assesses the economic feasibility of eliminating the traditional metal vents and replacing them with vents made of plastic materials used in condensing and power vent

269

A Small Scale Solar Agricultural Dryer with Biomass Burner and Heat Storage Back-Up Heater  

Science Journals Connector (OSTI)

This paper describes a small scale solar agricultural dryer with a simple biomass burner and heat storage back-up heater. The key design features ... are the combination of direct and indirect type solar dryer, t...

Elieser Tarigan; Perapong Tekasakul

2009-01-01T23:59:59.000Z

270

Development and Application of Engineering-Scale Solar Water Heater System Assisted by Heat Pump  

Science Journals Connector (OSTI)

An engineering-scale solar water heater system assisted by heat pump was developed based on ... . The subunits of modularized system include vacuum solar energy collectors, air source heat pump, ... Energy source...

Xiufeng Gao; Shiyu Feng; Wei Hu…

2009-01-01T23:59:59.000Z

271

Thermal performance evaluation of a solar air heater with and without thermal energy storage  

Science Journals Connector (OSTI)

This communication presents the experimental study and performance analysis of a solar air heater with and without phase change ... found that the output temperature in case with thermal energy storage (TES) is h...

V. V. Tyagi; A. K. Pandey; S. C. Kaushik…

2012-03-01T23:59:59.000Z

272

Design, modeling, and performance of four breadbox passive solar water heaters  

SciTech Connect (OSTI)

As part of the Southwest Border Regional Commission demonstration program on Solar Upgrading of Low-Income Housing, three different types of passive breadbox solar water heaters were designed. Using these designs, a total of six solar water heaters have been installed on public housing units in Las Cruces; these systems act as preheaters to the existing conventional gas-fired water heaters. Under a separate contract from the National Center for Appropriate Technology, four of these installations have been instrumented with two Btu meters each to measure the thermal output of both the solar preheater and conventional backup system. This has enabled measurement of the actual solar fraction of the four instrumented solar systems. The design and construction of the water heaters is described, and the actual performance of the systems is compared with the predicted performance.

Roberts, D. (Energy Management Services, Inc., Santa Fe, NM); Farrer, R.

1981-01-01T23:59:59.000Z

273

ENERGY STAR Residential Water Heaters to Save Americans Up to $823 Million  

Broader source: Energy.gov (indexed) [DOE]

STAR Residential Water Heaters to Save Americans Up to $823 STAR Residential Water Heaters to Save Americans Up to $823 Million in the Next Five Years ENERGY STAR Residential Water Heaters to Save Americans Up to $823 Million in the Next Five Years December 31, 2008 - 9:18am Addthis WASHINGTON - The U.S. Department of Energy (DOE) today announced the availability of ENERGY STAR® residential water heaters. With today's announcement, the ENERGY STAR® program now addresses every major residential appliance found in most American homes. Introduction of this product provides significant potential savings to consumers. Water heating represents up to 15.5 percent of national residential energy consumption, the second largest end use of energy in homes, following heating and cooling. Using one of five specified water heating technologies, ENERGY

274

Buildings Energy Data Book: 5.4 Water Heaters  

Buildings Energy Data Book [EERE]

5 5 Water Heater Efficiencies 2005 2010 Efficiency Stock Minimum Best-Available Residential Type Parameter (1) Efficiency New Efficiency New Efficiency Electric Storage EF 0.90 0.90 (2) 0.95 (2) Electric Instantaneous EF 0.82 0.82 0.98 Electric Heat Pump EF 2.00 2.00 2.35 Gas-Fired Storage EF 0.60 0.59 (3) 0.85 (3) Gas-Fired Instantaneous EF 0.82 0.82 0.98 Oil-Fired Storage EF 0.50 0.53 (4) 0.68 (4) Solar SEF 2.50 N.A. 2.50 2007 2010 Efficiency Stock Minimum Best-Available Commercial Type Parameter (1) Efficiency New Efficiency New Efficiency Electric Storage Thermal Efficiency 0.98 0.98 (5) 0.98 (5) Electric Instantaneous Thermal Efficiency 0.98 0.98 0.98 Gas-Fired Storage Thermal Efficiency 0.78 0.80 (6) 0.96 (6) Gas-Fired Instantaneous Thermal Efficiency 0.77 0.80 0.85 Oil-Fired Storage Thermal Efficiency 0.79 0.78 (7) 0.85 (7) Note(s):

275

Heat pump water heater and storage tank assembly  

DOE Patents [OSTI]

A water heater and storage tank assembly comprises a housing defining a chamber, an inlet for admitting cold water to the chamber, and an outlet for permitting flow of hot water from the chamber. A compressor is mounted on the housing and is removed from the chamber. A condenser comprises a tube adapted to receive refrigerant from the compressor, and winding around the chamber to impart heat to water in the chamber. An evaporator is mounted on the housing and removed from the chamber, the evaporator being adapted to receive refrigerant from the condenser and to discharge refrigerant to conduits in communication with the compressor. An electric resistance element extends into the chamber, and a thermostat is disposed in the chamber and is operative to sense water temperature and to actuate the resistance element upon the water temperature dropping to a selected level. The assembly includes a first connection at an external end of the inlet, a second connection at an external end of the outlet, and a third connection for connecting the resistance element, compressor and evaporator to an electrical power source.

Dieckmann, John T. (Belmont, MA); Nowicki, Brian J. (Watertown, MA); Teagan, W. Peter (Acton, MA); Zogg, Robert (Belmont, MA)

1999-09-07T23:59:59.000Z

276

Solar space- and water-heating system at Stanford University. Final report  

SciTech Connect (OSTI)

Application of an active hydronic domestic hot water and space heating solar system for the Central Food Services Building is discussed. The closed-loop drain-back system is described as offering dependability of gravity drain-back freeze protection, low maintenance, minimal costs, and simplicity. The system features an 840 square-foot collector and storage capacity of 1550 gallons. The acceptance testing and the predicted system performance data are briefly described. Solar performance calculations were performed using a computer design program (FCHART). Bidding, costs, and economics of the system are reviewed. Problems are discussed and solutions and recommendations given. An operation and maintenance manual is given in Appendix A, and Appendix B presents As-built Drawings. (MCW)

Not Available

1980-05-01T23:59:59.000Z

277

Performance of unglazed solar ventilation air pre-heaters for broiler barns  

Science Journals Connector (OSTI)

Solar radiation is an interesting heat source for applications requiring a limited amount of energy, such as pre-heating cold fresh air used in venting livestock barns. The objective of this study was to evaluate the energy recovery efficiency of a solar air pre-heater consisting of an unglazed perforated black corrugated siding where the incoming fresh ventilation air picks up heat from its face and back. Installed on the southeast wall of two broiler barns located 40 km east of Montreal, Canada, the performance of solar air pre-heaters was monitored over 2 years. Sensors inside the barns monitored the temperature of the ambient air, that pre-heated by the solar collector and that exhausted by one of the three operating fans. An on-site weather station measured ambient air temperature, wind direction and velocity and radiation energy absorbed on a vertical plane parallel to the unglazed solar air pre-heaters. The measured vertical solar radiation value was used to evaluate the heat recovery efficiency of the unglazed solar air pre-heaters. Using data from the Varennes Environment Canada weather station located 30 km northwest, the solar sensors were found to measure the absorbed solar radiation with a maximum error of 7%, including differences in exterior air moisture. Unglazed, the efficiency of the solar air pre-heaters reached 65% for wind velocities under 2 m/s, but dropped below 25% for wind velocities exceeding 7 m/s. Nevertheless, the unglazed solar air pre-heaters were able to reduce the heating load especially in March of both years. Over a period starting in November and ending in March, the solar air heaters recovered an energy value equivalent to an annual return on investment of 4.7%.

Sébastien Cordeau; Suzelle Barrington

2011-01-01T23:59:59.000Z

278

Space Heaters, Computers, Cell Phone Chargers: How Plugged In Are Commercial Buildings?  

E-Print Network [OSTI]

Refrigerators, Refrigerator-Freezers & Freezers. DOE/EE-refrigerator, commercial speakers switch, ethernet freezer,refrigerator, microscope, autoclave, shaker/stirrer, lab freezer,

Sanchez, Marla; Webber, Carrie; Brown, Richard; Busch, John; Pinckard, Margaret; Roberson, Judy

2007-01-01T23:59:59.000Z

279

Covered Product Category: Residential Heat Pump Water Heaters...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

used for many years for space heating and cooling. It can be found in small and large products alike, such as window air conditioners used in homes through large rooftop units...

280

The Newest Addition to the ENERGY STAR Lineup: Water Heaters | Department  

Broader source: Energy.gov (indexed) [DOE]

The Newest Addition to the ENERGY STAR Lineup: Water Heaters The Newest Addition to the ENERGY STAR Lineup: Water Heaters The Newest Addition to the ENERGY STAR Lineup: Water Heaters February 17, 2009 - 9:48am Addthis Elizabeth Spencer Communicator, National Renewable Energy Laboratory If you've gone shopping for new appliances sometime in the last decade, then you're probably familiar with the ENERGY STAR® label. ENERGY STAR is a partnership between the U.S. Department of Energy and the U.S. Environmental Protection Agency that sets higher-than-average standards for household appliances, electronics, and commercial products. Products that meet these rigorous energy requirements can be designated as ENERGY STAR products. For the average consumer, it basically means that ENERGY STAR products are more energy efficient than their standard counterparts, and therefore will

Note: This page contains sample records for the topic "hydronic space heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

City of San Jose - Solar Hot Water Heaters and Photovoltaic Systems Permit  

Broader source: Energy.gov (indexed) [DOE]

San Jose - Solar Hot Water Heaters and Photovoltaic Systems San Jose - Solar Hot Water Heaters and Photovoltaic Systems Permit Requirements City of San Jose - Solar Hot Water Heaters and Photovoltaic Systems Permit Requirements < Back Eligibility Commercial Construction Industrial Installer/Contractor Multi-Family Residential Residential Savings Category Solar Buying & Making Electricity Program Info State California Program Type Solar/Wind Permitting Standards Provider City of San Jose Building, Planning and Electrical Permits are required for Photovoltiac (PV) systems installed in San Jose. In most cases, PV systems must also undergo a Building Plan Review and an Electrical Plan Review. Building Plan Reviews are not required for installations that meet all of the following criteria: 1. Total panel weight (including frame) is not greater than 5 lbs. per

282

Performance of Heat Pump Water Heaters: Initial Findings of Draw Profile Effect on HPWH Efficiency  

Broader source: Energy.gov (indexed) [DOE]

Performance of Heat Pump Water Heaters Performance of Heat Pump Water Heaters © 2011 Steven Winter Associates, Inc. All rights reserved. © 2011 Steven Winter Associates, Inc. All rights reserved. Evaluation Overview  2000-2002 Evaluated 20 installations with CL&P  Product had problems; not ready for prime time (average COPs of 1.67 was not the problem)  New batch of heaters available, including:  GE's GeoSpring Hybrid (50 gal)  A.O.Smith's Voltex Hybrid (60 & 80 gal)  Stiebel-Eltron's Accelera 300 (80 gal)  Evaluating 14 installations for National Grid, NSTAR, & Cape Light Compact. © 2011 Steven Winter Associates, Inc. All rights reserved. © 2011 Steven Winter Associates, Inc. All rights reserved.

283

Development status of coal-fired gas heaters for Brayton-cycle cogeneration systems  

SciTech Connect (OSTI)

Under contract from the Department of Energy, Rocketdyne is developing the technology of coal-fired gas heaters for utilization in Brayton-cycle cogeneration systems. The program encompasses both atmospheric fluidized bed and pulverized coal combustion systems; and it is directed toward the development of gas heater systems capable of delivering high pressure air or helium at 1550 F, when employing metallic heat exchangers, and 1750 F, when employing ceramic heat exchangers. This paper reports on the development status of the program, with discussions of the completed ''screening'' corrosion/erosion tests of candidate heat exchanger materials, a description and summary of the operating experience with the 6- by 6-foot AFB test facility and a projection of the potential for relatively near term commercialization of such heater systems.

Gunn, S.V.; McCarthy, J.R.

1983-01-01T23:59:59.000Z

284

Refractory oxides for high?temperature coal?fired MHD air heaters  

Science Journals Connector (OSTI)

In a coal?burning MHD (Magnetohydrodynamic) power plant the use of a regenerative air heater is one option for producing the required high plasma temperatures. However thermal mechanical and chemical stresses which the MHD environment places on materials are enormous and candidate materials must be carefully tested. We report on the results of such testing for a variety of materials studied in heater test facilities at both FluiDyne Engineering Corporation and at Montana State University. We describe the experimental program and test facilities for MHD heater development the rationale for the choice of materials and their performance (success or failure) under various envirnoments (slagging and nonslagging). Future materials needs are discussed in light of the observed effects.

Richard J. Pollina; Ronald R. Smyth

1981-01-01T23:59:59.000Z

285

Development of Industrially Produced Composite Quench Heaters for the LHC Superconducting Lattice Magnets  

E-Print Network [OSTI]

The quench heaters are vital elements for the protection of the LHC superconducting lattice magnets in the case of resistive transitions of the conductor. The basic concept of magnet protection and technical solutions are briefly presented. The quench heater consists of partially copper clad stainless steel strips sandwiched in between electric insulating carrier foils with electrical and mechanical properties such as to withstand high voltages, low temperatures, pressures and ionizing radiation. Testing of some commercial available electric insulation foils, polyimide (PI), polyetheretherketon (PEEK) and polyarylate (PA) and combinations of adhesive systems which are suitable for industrial processing are described. Possible industrial methods for series production for some 80 km of these composite quench heaters are indicated.

Szeless, Balázs; Calvone, F

1996-01-01T23:59:59.000Z

286

City-level energy and CO2 reduction effect by introducing new residential water heaters  

Science Journals Connector (OSTI)

Simulation models for a variety of new water heater systems were developed and the models were integrated into a city-level residential energy end-use model for Osaka City. Using the model, the potential of energy conservation and CO2 emission-reduction by introducing new residential water heaters was evaluated at the city-level. Optimal water-heating systems for each household category for primary energy reduction, CO2 emission-reduction, or cost reduction were identified by applying the end-use demand model. The effect of subsidies for installing more efficient systems and the influence of diffusion of these systems on electricity load curves were also discussed.

Yoshiyuki Shimoda; Tomo Okamura; Yohei Yamaguchi; Yukio Yamaguchi; Ayako Taniguchi; Takao Morikawa

2010-01-01T23:59:59.000Z

287

DETERMINATION OF IN-SITU THERMAL PROPERTIES OF STRIPA GRANITE FROM TEMPERATURE MEASUREMENTS IN THE FULL-SCALE HEATER EXPERIMENTS: METHOD AND PRELIMINARY RESULTS  

E-Print Network [OSTI]

observed temperatures for the Lulea University pilot heaterPower room '--_I, I\\'~ \\,1 Lulea drift I I I I I I I I Ithe temperature data from the LUlea University pilot heater

Jeffry, J.A.

2010-01-01T23:59:59.000Z

288

ISSUANCE 2014-12-23: Energy Conservation Program for Consumer Products: Test Procedures for Direct Heating Equipment and Pool Heaters, Final Rule  

Broader source: Energy.gov [DOE]

Energy Conservation Program for Consumer Products: Test Procedures for Direct Heating Equipment and Pool Heaters, Final Rule

289

Property:Building/SPElectrtyUsePercElctrcEngineHeaters | Open Energy  

Open Energy Info (EERE)

SPElectrtyUsePercElctrcEngineHeaters SPElectrtyUsePercElctrcEngineHeaters Jump to: navigation, search This is a property of type String. Electric engine heaters Pages using the property "Building/SPElectrtyUsePercElctrcEngineHeaters" Showing 25 pages using this property. (previous 25) (next 25) S Sweden Building 05K0001 + 0.0 + Sweden Building 05K0002 + 0.0 + Sweden Building 05K0003 + 0.0 + Sweden Building 05K0004 + 0.0 + Sweden Building 05K0005 + 0.0 + Sweden Building 05K0006 + 3.74913558105 + Sweden Building 05K0007 + 0.0 + Sweden Building 05K0008 + 0.0 + Sweden Building 05K0009 + 0.625045331062 + Sweden Building 05K0010 + 0.0 + Sweden Building 05K0011 + 0.0 + Sweden Building 05K0012 + 2.19814987082 + Sweden Building 05K0013 + 0.0 + Sweden Building 05K0014 + 0.0 + Sweden Building 05K0015 + 0.0 +

290

Property:Building/SPBreakdownOfElctrcityUseKwhM2ElctrcEngineHeaters | Open  

Open Energy Info (EERE)

ElctrcEngineHeaters ElctrcEngineHeaters Jump to: navigation, search This is a property of type String. Electric engine heaters Pages using the property "Building/SPBreakdownOfElctrcityUseKwhM2ElctrcEngineHeaters" Showing 25 pages using this property. (previous 25) (next 25) S Sweden Building 05K0001 + 0.0 + Sweden Building 05K0002 + 0.0 + Sweden Building 05K0003 + 0.0 + Sweden Building 05K0004 + 0.0 + Sweden Building 05K0005 + 0.0 + Sweden Building 05K0006 + 2.44788473329 + Sweden Building 05K0007 + 0.0 + Sweden Building 05K0008 + 0.0 + Sweden Building 05K0009 + 0.353408923575 + Sweden Building 05K0010 + 0.0 + Sweden Building 05K0011 + 0.0 + Sweden Building 05K0012 + 0.835160644485 + Sweden Building 05K0013 + 0.0 + Sweden Building 05K0014 + 0.0 + Sweden Building 05K0015 + 0.0 +

291

An International Survey of Electric Storage Tank Water Heater Efficiency and Standards  

SciTech Connect (OSTI)

Water heating is a main consumer of energy in households, especially in temperate and cold climates. In South Africa, where hot water is typically provided by electric resistance storage tank water heaters (geysers), water heating energy consumption exceeds cooking, refrigeration, and lighting to be the most consumptive single electric appliance in the home. A recent analysis for the Department of Trade and Industry (DTI) performed by the authors estimated that standing losses from electric geysers contributed over 1,000 kWh to the annual electricity bill for South African households that used them. In order to reduce this burden, the South African government is currently pursuing a programme of Energy Efficiency Standards and Labelling (EES&L) for electric appliances, including geysers. In addition, Eskom has a history of promoting heat pump water heaters (HPWH) through incentive programs, which can further reduce energy consumption. This paper provides a survey of international electric storage water heater test procedures and efficiency metrics which can serve as a reference for comparison with proposed geyser standards and ratings in South Africa. Additionally it provides a sample of efficiency technologies employed to improve the efficiency of electric storage water heaters, and outlines programs to promote adoption of improved efficiency. Finally, it surveys current programs used to promote HPWH and considers the potential for this technology to address peak demand more effectively than reduction of standby losses alone

Johnson, Alissa; Lutz, James; McNeil, Michael A.; Covary, Theo

2013-11-13T23:59:59.000Z

292

Enhanced heat transfer tubes for film absorbers of absorption chiller/heater  

SciTech Connect (OSTI)

Absorption chiller/heaters using non-CFC refrigerants are attracting attention as environmentally friendly energy systems. As the refrigerant/absorbent pair, the water/lithium bromide aqueous solution pair is preferably used for most absorption chiller/heaters in Japan. Absorption chiller/heaters, mainly used as water chillers and air-conditioners, are commercially available at least for unit cooling capacities above 60 kW. In absorption chiller/heaters, the absorber must be made compact, because the absorber has the largest heat transfer area of the four primary heat exchangers in the system: the evaporator, absorber, regenerator and condenser. Although a great amount of information is available on the evaporator and condenser, the same type of information concerning the absorber is lacking. This paper introduces two kinds of double fluted tubes called Arm tubs and Floral tubes for film absorbers. Arm tubes are manufactured using a two-pass drawbench process, while Floral tubes are made using a single pass drawbench process. The experiments using a lithium bromide aqueous solution with the addition of 250 ppm n-octyl alcohol as the surfactant showed that Arm tubes and Floral tubes had about 40% higher heat transfer performance than plain tubes. Therefore, Floral tubes are expected to realize a high performance at low cost. Furthermore, the optimization of the number of grooves on the outside of the tubes is also described here.

Sasaki, Naoe; Nosetani, Tadashi [Sumitomo Light Metal Industry, Ltd., Nagoya, Aichi (Japan); Furukawa, Masahiro; Kaneko, Toshiyuki [Sanyo Electric Co., Ltd., Ora, Gunma (Japan). Commercial Air-Conditioning Div.

1995-12-31T23:59:59.000Z

293

An Energy-Efficient Self-Regulating Heater for Flow-Through Applications  

Science Journals Connector (OSTI)

Except for the bifilar wire (two strands separately insulated, as in household two-conductor cable, except in miniature, the fabrication of the other heaters is the same. ... The heated reactor was wrapped in foam sheets for insulation and put inside a 25-mm-thick plastic box. ...

Purnendu K. Dasgupta; Ellis L. Loree; Jianzhong Li; Zhang Genfa

2003-06-12T23:59:59.000Z

294

Efficient generation of extended plasma waveguides with the axicon ignitor-heater scheme  

E-Print Network [OSTI]

. The plasma col- umn was produced by using an axicon to focus a long laser pulse into a line focusEfficient generation of extended plasma waveguides with the axicon ignitor-heater scheme Y.-F. Xiao for generating extended plasma waveguides is developed by using the axicon lens in conjunction with the ignitor

295

Refrigerant charge management in a heat pump water heater  

DOE Patents [OSTI]

Heat pumps that heat or cool a space and that also heat water, refrigerant management systems for such heat pumps, methods of managing refrigerant charge, and methods for heating and cooling a space and heating water. Various embodiments deliver refrigerant gas to a heat exchanger that is not needed for transferring heat, drive liquid refrigerant out of that heat exchanger, isolate that heat exchanger against additional refrigerant flowing into it, and operate the heat pump while the heat exchanger is isolated. The heat exchanger can be isolated by closing an electronic expansion valve, actuating a refrigerant management valve, or both. Refrigerant charge can be controlled or adjusted by controlling how much liquid refrigerant is driven from the heat exchanger, by letting refrigerant back into the heat exchanger, or both. Heat pumps can be operated in different modes of operation, and segments of refrigerant conduit can be interconnected with various components.

Chen, Jie; Hampton, Justin W.

2014-06-24T23:59:59.000Z

296

NEXT GENERATION COMMERCIAL HEAT PUMPWATER HEATER USING CARBON DIOXIDE USING DIFFERENT IMPROVEMENT APPROACHES  

SciTech Connect (OSTI)

Although heat pump water heaters are today widely accepted in Japan, where energy costs are high and government incentives for their use exist, acceptance of such a product in the U.S. has been slow. This trend is slowly changing with the introduction of heat pump water heaters into the residential market, but remains in the commercial sector. Barriers to heat pump water heater acceptance in the commercial market have historically been performance, reliability and first/operating costs. The use of carbon dioxide (R744) as the refrigerant in such a system can improve performance for relatively small increase in initial cost and make this technology more appealing. What makes R744 an excellent candidate for use in heat pump water heaters is not only the wide range of ambient temperatures within which it can operate, but also the excellent ability to match water to refrigerant temperatures on the high side, resulting in very high exit water temperatures of up to 82�ºC, as required by sanitary codes in the U.S. (Food Code, 2005), in a single pass, temperatures that are much more difficult to reach with other refrigerants. This can be especially attractive in applications where this water is used for the purpose of sanitation. While reliability has also been of concern historically, dramatic improvements have been made over the last several years through research done in the automotive industry and commercialization of R744 technology in residential water heating mainly in Japan. This paper presents the performance results from the development of an R744 commercial heat pump water heater of approximately 35 kW and a comparison to a baseline R134a unit of the same capacity and footprint. In addition, recommendations are made for further improvements of the R744 system which could result in possible energy savings of up to 20 %.

Chad Bowers; Michael Petersen; Stefan Elbel; Pega Hrnjak

2012-04-01T23:59:59.000Z

297

Eliminating air heater plugging and corrosion caused by SCR/SNCR systems for NOx control on coal-fired boilers  

SciTech Connect (OSTI)

In a typical coal-fired power plant the rotary regenerative air heater is responsible for 5-10% of the boiler's total efficiency. The three biggest threats to air heater performance deterioration are corrosion of the heat exchange surfaces, plugging, and air heater leakage through the seals. The article concentrates on the vastly increased level of corrosion and plugging issues associated with installing selective catalytic reduction (SCR) and selective non-catalytic reduction (SNCR) systems for controlling nitrogen oxide emissions. Some injected ammonia in the SCR process reacts with SO{sub 2} to form ammonium sulphate and bisulphate (ABS) which is deposited on the air heater element surfaces. This can be overcome by applying coatings, using corrosion-resistant steels, reconfiguring the air heaters to a two layer design, improving air heater blowers, improving technologies for removing ammonia 'slip' before it enters the air heater, and using new catalysts that reduce the oxidation of SO{sub 2} to SO{sub 3}. 4 figs.

Guffre, J. [Paragon Airheater Technologies (United States)

2007-10-15T23:59:59.000Z

298

Heat Pump Water Heater Technology Assessment Based on Laboratory Research and Energy Simulation Models: Preprint  

SciTech Connect (OSTI)

This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of US climate regions. Laboratory results demonstrate the efficiency of this technology under most of the conditions tested and show that differences in control schemes and design features impact the performance of the individual units. These results were used to understand current model limitations, and then to bracket the energy savings potential for HPWH technology in various US climate regions. Simulation results show that HPWHs are expected to provide significant energy savings in many climate zones when compared to other types of water heaters (up to 64%, including impact on HVAC systems).

Hudon, K.; Sparn, B.; Christensen, D.; Maguire, J.

2012-02-01T23:59:59.000Z

299

Radiation Tolerant Programmable Power Supply for the LHC Beam Screen Heaters  

E-Print Network [OSTI]

For the next LHC run, it is required to install 200W of heating capacity per LHC beam screen heater to regenerate the beam screen by desorption of gas trapped on its walls. In the LHC, there are 272 beam screen heaters and the associated electronics limit presently the heating capacity to 25W. Those electronics are, for the most part, installed inside the LHC tunnel and exposed to its radiation environment. This paper describes the development of a new programmable power supply card that will be integrated into the existing LHC radiation tolerant electronic infrastructure used by the cryogenic system. Radiation tests were undertaken to qualify a power switch capable of coping with the 230Vrms grid voltage and an analog signal multiplexer; these components are required respectively for satisfying the higher power requirements and for reducing the overall cost by using a single analog to digital converter to sample all the signals.

Casas, J

2014-01-01T23:59:59.000Z

300

MHD air heater technology development. Annual technical progress report, January 1, 1980-December 31, 1980  

SciTech Connect (OSTI)

Progress on the technology development of the directly-fired high temperature air heater (HTAH) for MHD power plants is described in detail. The objective of task 1 is to continue development of ceramic materials technology for the directly-fired HTAH. The objectives of task 2 are to demonstrate the technical feasibility of operating a directly-fired HTAH (including both the heater matrix and valves), to continue obtaining information on life and corrosion resistance of HTAH materials, and to obtain design information for full-scale studies and future design work. The objectives of task 3 are to begin the identification of HTAH control requirements and control system needs, and to continue full-scale study efforts incorporating updated materials and design information in order to identify development needs for the HTAH development program. (WHK)

None

1981-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "hydronic space heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Experimental study of a thermosyphon solar water heater coupled to a fibre-reinforced plastic (FRP) storage tank  

Science Journals Connector (OSTI)

The thermal performance of the thermosyphon solar water heater was analyzed to show its ... %. Also, an analysis of the temperature storage characteristics of a novel fibre-reinforced plastic (FRP) storage tank w...

P. N. Nwosu; O. U. Oparaku; W. I. Okonkwo; G. O. Unachukwu…

2011-09-01T23:59:59.000Z

302

Thermal calculation of combined transpiration-liquid cooling of discharge-chamber walls of an electric-arc heater  

Science Journals Connector (OSTI)

The article presents a theoretical calculation of the temperature profiles and optimal thicknesses of porous and solid cooled walls, which provide a steady-state operation of an electric-arc heater with transpira...

G. L. Dobroedov; V. I. Krylovich

1970-03-01T23:59:59.000Z

303

Performance Analysis of a Transcritical CO2 Heat Pump Water Heater Incorporating a Brazed-Plate Gas-cooler.  

E-Print Network [OSTI]

??This study focuses on the experimental testing and numerical modeling of a 4.5 kW transcritical CO2 heat pump water heater at Queen’s University in the… (more)

Murray, PORTIA

2015-01-01T23:59:59.000Z

304

Field Performance of Heat Pump Water Heaters in the Northeast, Massachusetts and Rhode Island (Fact Sheet)  

SciTech Connect (OSTI)

Heat pump water heaters (HPWHs) are finally entering the mainstream residential water heater market. Potential catalysts are increased consumer demand for higher energy efficiency electric water heating and a new Federal water heating standard that effectively mandates use of HPWHs for electric storage water heaters with nominal capacities greater than 55 gallons. When compared to electric resistance water heating, the energy and cost savings potential of HPWHs is tremendous. Converting all electric resistance water heaters to HPWHs could save American consumers 7.8 billion dollars annually ($182 per household) in water heating operating costs and cut annual residential source energy consumption for water heating by 0.70 quads. Steven Winter Associates, Inc. embarked on one of the first in situ studies of these newly released HPWH products through a partnership with two sponsoring electric utility companies, National Grid and NSTAR, and one sponsoring energy efficiency service program administrator, Cape Light Compact. Recent laboratory studies have measured performance of HPWHs under various operating conditions, but publicly available field studies have not been as available. This evaluation attempts to provide publicly available field data on new HPWHs by monitoring the performance of three recently released products (General Electric GeoSpring, A.O. Smith Voltex, and Stiebel Eltron Accelera 300). Fourteen HPWHs were installed in Massachusetts and Rhode Island and monitored for over a year. Of the 14 units, ten were General Electric models (50 gallon units), two were Stiebel Eltron models (80 gallon units), and two were A.O. Smith models (one 60-gallon and one 80-gallon unit).

Not Available

2013-12-01T23:59:59.000Z

305

Microcantilever heater-thermometer with integrated temperature-compensated strain sensor  

DOE Patents [OSTI]

The present invention provides microcantilever hotplate devices which incorporate temperature compensating strain sensors. The microcantilever hotplate devices of the present invention comprise microcantilevers having temperature compensating strain sensors and resistive heaters. The present invention also provides methods for using a microcantilever hotplate for temperature compensated surface stress measurements, chemical/biochemical sensing, measuring various properties of compounds adhered to the microcantilever hotplate surface, or for temperature compensated deflection measurements.

King, William P. (Champaign, IL); Lee, Jungchul (Champaign, IL); Goericke, Fabian T. (Wolfsburg, DE)

2011-04-19T23:59:59.000Z

306

Evaluation of TANK Water Heater Simulation Model as Embedded in HWSim  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

TANK Water Heater Simulation Model as Embedded in HWSim TANK Water Heater Simulation Model as Embedded in HWSim Title Evaluation of TANK Water Heater Simulation Model as Embedded in HWSim Publication Type Report LBNL Report Number LBNL-5092E Year of Publication 2010 Authors Lutz, James D. Document Number LBNL-5092E Pagination 11 Date Published December 22 Publisher Lawrence Berkeley National Laboratory City Berkeley ISBN Number LBNL-5092E Abstract This report evaluates the hot water temperatures and flow rates as calculated by the combined HWSim and TANK simulation models. Notes This work was sponsored by the Gas Technology Institute (GTI) which is funded by the California Energy Commission, Public Interest Energy Research (PIER) Program, under Residential Water Heating Program Contract No. 500-08-060. This work was supported by the Assistant Secretary for Energy Efficiency and Renewable Energy, Office of Building Technology, State, and Community Programs, of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231.

307

Advanced Oxyfuel Boilers and Process Heaters for Cost Effective CO2 Capture and Sequestration  

SciTech Connect (OSTI)

The purpose of the advanced boilers and process heaters program is to assess the feasibility of integrating Oxygen Transport Membranes (OTM) into combustion processes for cost effective CO{sub 2} capture and sequestration. Introducing CO{sub 2} capture into traditional combustion processes can be expensive, and the pursuit of alternative methods, like the advanced boiler/process heater system, may yield a simple and cost effective solution. In order to assess the integration of an advanced boiler/process heater process, this program addressed the following tasks: Task 1--Conceptual Design; Task 2--Laboratory Scale Evaluation; Task 3--OTM Development; Task 4--Economic Evaluation and Commercialization Planning; and Task 5--Program Management. This Final report documents and summarizes all of the work performed for the DOE award DE-FC26-01NT41147 during the period from January 2002-March 2007. This report outlines accomplishments for the following tasks: conceptual design and economic analysis, oxygen transport membrane (OTM) development, laboratory scale evaluations, and program management.

Max Christie; Rick Victor; Bart van Hassel; Nagendra Nagabushana; Juan Li; Joseph Corpus; Jamie Wilson

2007-03-31T23:59:59.000Z

308

Development and Field Trial of Dimpled-Tube Technology for Chemical Industry Process Heaters  

SciTech Connect (OSTI)

Most approaches to increasing heat transfer rates in the convection sections of gas-fired process heaters involve the incorporation of fins, baffles, turbulizers, etc. to increase either the heat transfer surface area or turbulence or both. Although these approaches are effective in increasing the heat transfer rates, this increase is invariably accompanied by an associated increase in convection section pressure drop as well as, for heaters firing ‘dirty’ fuel mixtures, increased fouling of the tubes – both of which are highly undesirable. GTI has identified an approach that will increase heat transfer rates without a significant increase in pressure drop or fouling rate. Compared to other types of heat transfer enhancement approaches, the proposed dimpled tube approach achieves very high heat transfer rates at the lowest pressure drops. Incorporating this approach into convection sections of chemical industry fired process heaters may increase energy efficiency by 3-5%. The energy efficiency increase will allow reducing firing rates to provide the required heating duty while reducing the emissions of CO2 and NOx.

Yaroslav Chudnovsky; Aleksandr Kozlov

2006-10-12T23:59:59.000Z

309

Analysis of water heater standby energy consumption from ELCAP homes  

Science Journals Connector (OSTI)

The Bonneville Power Administration (Bonneville) routinely prepares forecasts of future energy demands in the Pacific Northwest region of the United States. Bonneville also implements conservation programs to reduce load demands. Results from the End-Use Load and Consumer Assessment Program (ELCAP), undertaken by the Pacific Northwest Laboratory for Bonneville, indicated that single-family homes with electric space-heating equipment consume more than 4700 kWh/yr to heat water for domestic uses. This energy use amounts to about 23% of the total electricity consumed. Additionally, the peak consumption for water heating coincides with regional system peak demands. Detailed analyses of the water heating end-use data acquired for residential buildings in ELCAP reveal that the average standby load for existing homes is 1200 kWh/yr, while homes built as part of the Residential Standards Demonstration Program averaged 1100 kWh/yr. These figures are consistent with the current figure of 1300 kWh/yr that is being used in the regional energy forecast. We also determined that standby loads for some of the participants were behaviorally driven. The data indicated the occurrence of vacancy setbacks in which the participant appears to lower the thermostat to save energy while the house is vacant. Anecdotal evidence from interviews revealed that this does occur. Reasons for setting back the thermostat ranged from not thinking about using the breaker, to fear that the tank would freeze in cold weather. These types of activities also appear to create the occurrence of dueling thermostats where the upper and lower thermostats, after the vacancy period, are not returned to the same temperature. This leads to additional energy use in an attempt to maintain a uniform temperature in the tank.

R.G. Pratt; B.A. Ross; W.F. Sandusky

1993-01-01T23:59:59.000Z

310

Optimizing Hydronic System Performance in Residential Applications...  

Energy Savers [EERE]

modulating condensing boiler; indirect domestic hot water tank; variable-speed pumps; baseboard convectors. A buffer tank was compared to primary-secondary piping....

311

Microsoft Word - ASHRAE_Water Heater Paper_2010-11-24_Final_LBNL_.docx  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Energy Efficiency Design Options for Residential Water Heaters: Economic Impacts on Consumers Presented at: 2011 ASHRAE Winter Conference, Las Vegas, Nevada January 2011 Alex B. Lekov, Victor H. Franco, Steve Meyers, Lisa Thompson, and Virginie Letschert Lawrence Berkeley National Laboratory Environmental Energy Technologies Division One Cyclotron Road Berkeley, CA 94720 This work was supported by the Assistant Secretary for Energy Efficiency and Renewable Energy, Office of Building Technology, State, and Community Programs, of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231. ERNEST ORLANDO LAWRENCE BERKELEY NATIONAL LABORATORY 2 Disclaimer This document was prepared as an account of work sponsored by the United States

312

Advanced Process Heater for the Steel, Aluminum and Chemical Industries of the Future  

SciTech Connect (OSTI)

The Roadmap for Process Heating Technology (March 16, 2001), identified the following priority R&D needs: “Improved performance of high temperature materials; improved methods for stabilizing low emission flames; heating technologies that simultaneously reduce emissions, increase efficiency, and increase heat transfer”. Radiant tubes are used in almost every industry of the future. Examples include Aluminum re-heat furnaces; Steel strip annealing furnaces, Petroleum cracking/ refining furnaces, Metal Casting/Heat Treating in atmosphere and fluidized bed furnaces, Glass lair annealing furnaces, Forest Products infrared paper driers, Chemical heat exchangers and immersion heaters, and the indirect grain driers in the Agriculture Industry. Several common needs among the industries are evident: (1) Energy Reductions, (2) Productivity Improvements, (3) Zero Emissions, and (4) Increased Component Life. The Category I award entitled “Proof of Concept of an Advanced Process Heater (APH) for Steel, Aluminum, and Petroleum Industries of the Future” met the technical feasibility goals of: (1) doubling the heat transfer rates (2) improving thermal efficiencies by 20%, (3) improving temperature uniformity by 100oF (38 oC) and (4) simultaneously reducing NOx and CO2 emissions. The APH addresses EERE’s primary mission of increasing efficiency/reducing fuel usage in energy intensive industries. The primary goal of this project was to design, manufacture and test a commercial APH prototype by integrating three components: (1) Helical Heat Exchanger, (2) Shared Wall Radiant U-tube, and (3) Helical Flame Stabilization Element. To accomplish the above, a near net shape powder ceramic Si-SiC low-cost forming process was used to manufacture the components. The project defined the methods for making an Advanced Process Heater that produced an efficiency between 70% to 80% with temperature uniformities of less than 5oF/ft (9oC/m). Three spin-off products resulted from this project: (1) a low-cost, high-temperature heat exchanger, (2) a new radiant heat transfer system, and (3) a hybrid or integral advanced process heater that incorporates a high surface area ceramic heat exchanger and burner combined with either a metallic or ceramic radiant tube and heat transfer elements.

Thomas D. Briselden

2007-10-31T23:59:59.000Z

313

2014-06-27 Issuance: Test Procedures for Residential and Commercial Water Heaters; Final Rule  

Broader source: Energy.gov [DOE]

This document is a pre-publication Federal Register final rule regarding test procedures for residential and commercial water heaters, as issued by the Deputy Assistant Secretary for Energy Efficiency on June 27, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

314

Control Strategy for Domestic Water Heaters during Peak Periods and its Impact on the Demand for Electricity  

Science Journals Connector (OSTI)

Because they store hot water, water heaters are easily-shifted loads that can be controlled to reduce peak demands. However, load shifting may have some detrimental consequences on the domestic hot water supply temperature if the heating element is deactivated for a long period of time. Furthermore, a new peak may be caused if a significant number of heaters are reactivated at the same time. This study presents a control strategy for water heaters that minimizes the pick-up demand when the heating elements are reactivated at the end of a load shifting period and that ensures, in all cases, the client's hot water supply. The study is based on a simulation model of a water heater that was experimentally validated and takes into account the diversity of the population's hot water withdrawal profile. More specifically, the data of 8,167 real water withdrawal profiles of several clients were input into the simulation model in order to evaluate the performance of water heaters under different operating conditions.

Alain Moreau

2011-01-01T23:59:59.000Z

315

Feasibility of Using Measurements of Internal Components ofTankless Water Heaters for Field Monitoring of Energy and Water Use  

SciTech Connect (OSTI)

The objective of this study was to determine if it was feasible to collect information regarding energy use and hot water delivery from tankless gas water heaters using the sensors and controls built into the water heaters. This could then be used to determine the water heater efficiency ? the ratio of energy out (hot water delivered) to energy in (energy in the gas) in actual residential installations. The goal was to be as unobtrusive as possible, and to avoid invalidating warranties or exposing researchers to liability issues. If feasible this approach would reduce the costs of instrumentation.This paper describes the limited field and laboratory investigations to determine if using the sensors and controls built into tankless water heaters is feasible for field monitoring.It was more complicated to use the existing gas flow, water and temperature sensors than was anticipated. To get the signals from the existing sensors and controls is difficult and may involve making changes that would invalidate manufacturer warrantees. The procedures and methods for using signals from the existing gas valves, water flow meters and temperature sensors will vary by model. To be able to monitor different models and brands would require detailed information about each model and brand.Based on these findings, we believe that for field monitoring projects it would be easier, quicker and safer to connect external meters to measure the same parameters rather than using the sensors and controls built into tankless water heaters.

Lutz, Jim; Biermayer, Peter

2008-04-17T23:59:59.000Z

316

Research and Design of a Sample Heater for Beam Line 6-2c Transmission X-ray Microscope  

SciTech Connect (OSTI)

There exists a need for environmental control of samples to be imaged by the Transmission X-Ray Microscope (TXM) at the SSRLs Beam Line 6-2c. In order to observe heat-driven chemical or morphological changes that normally occur in situ, microscopes require an additional component that effectively heats a given sample without heating any of the microscope elements. The confinement of the heat and other concerns about the heaters integrity limit which type of heater is appropriate for the TXM. The bulk of this research project entails researching different heating methods used previously in microscopes, but also in other industrial applications, with the goal of determining the best-fitting method, and finally in designing a preliminary sample heater.

Policht, Veronica; /Loyola U., Chicago /SLAC

2012-08-27T23:59:59.000Z

317

Feasibility of accompanying uncontrolled linear heater with solar system in natural gas pressure drop stations  

Science Journals Connector (OSTI)

Natural gas (NG) must be preheated before pressure reduction takes places at City Gate Stations (CGS). Indirect Water Bath Gas Heaters are employed in the CGS for preheating. The heaters consume a considerable amount of NG for preheating. As low temperature is required, a solar system has been proposed to provide part of heat demand. The system consists of a collector array and a storage tank. The tank stores solar heat during the day and releases it during the night. To show the capabilities of the proposed system, the Akand CGS has been chosen as a case study. The results show that as the number of collector increases, the fuel cost decreases but the capital cost increases. An optimum number of collectors and the storage tank capacity have been found based on economic analysis. The fuel saving occurs throughout the year with the maximum at June. The economic feasibility study of the proposed system has been carried out using two methods. These methods are Simple Payback Ratio (SPR) and (Net Present Value) NPV. The first one unveils that the payback ratio is only 6.9 years. The NPV method shows that the system will give net benefit after 11 years.

M. Farzaneh-Gord; A. Arabkoohsar; M. Deymi Dasht-bayaz; V. Farzaneh-Kord

2012-01-01T23:59:59.000Z

318

Modeling of Electric Water Heaters for Demand Response: A Baseline PDE Model  

SciTech Connect (OSTI)

Demand response (DR)control can effectively relieve balancing and frequency regulation burdens on conventional generators, facilitate integrating more renewable energy, and reduce generation and transmission investments needed to meet peak demands. Electric water heaters (EWHs) have a great potential in implementing DR control strategies because: (a) the EWH power consumption has a high correlation with daily load patterns; (b) they constitute a significant percentage of domestic electrical load; (c) the heating element is a resistor, without reactive power consumption; and (d) they can be used as energy storage devices when needed. Accurately modeling the dynamic behavior of EWHs is essential for designing DR controls. Various water heater models, simplified to different extents, were published in the literature; however, few of them were validated against field measurements, which may result in inaccuracy when implementing DR controls. In this paper, a partial differential equation physics-based model, developed to capture detailed temperature profiles at different tank locations, is validated against field test data for more than 10 days. The developed model shows very good performance in capturing water thermal dynamics for benchmark testing purposes

Xu, Zhijie; Diao, Ruisheng; Lu, Shuai; Lian, Jianming; Zhang, Yu

2014-09-05T23:59:59.000Z

319

Analysis of thermal properties of basalt from heater Test No. 2 experiment  

SciTech Connect (OSTI)

Rockwell Hanford Operations is conducting a series of full-scale in situ tests at the Near Surface Test Facility (NSTF) near Richland, Washington as an integral part of the Basalt Waste isolation project. An objective of the Phase I tests, which include Main Heater Test No. 2, is to provide data for determination the material properties necessary for predicting the response of a repository system at depth. During the first 90 days Heater Test No. 2 represents the near-field response of a high-level waste canister which generates 1 kW of heat energy. The analysis of the thermal response of basalt from data collected during this initial heating period is described in this report. Values of thermal conductivity and heat capacity for basalt are determined using three methods referred to as type curve matching, Jacob's straight line method, and the Gauss-Newton parameter optimization method. Results indicate that the type curve and the Gauss-Newton methods give values which correspond relatively closely to those measured in the laboratory.

Huyakorn, P.; Williams, J.R.; Thomas, S. (GeoTrans, Inc., Reston, VA (USA); Applied Mechanics, Inc., Grand Junction, CO (USA); GeoTrans, Inc., Reston, VA (USA))

1981-10-04T23:59:59.000Z

320

Effect of Fuel Wobbe Number on Pollutant Emissions from Advanced Technology Residential Water Heaters: Results of Controlled Experiments  

SciTech Connect (OSTI)

The research summarized in this report is part of a larger effort to evaluate the potential air quality impacts of using liquefied natural gas in California. A difference of potential importance between many liquefied natural gas blends and the natural gas blends that have been distributed in California in recent years is the higher Wobbe number of liquefied natural gas. Wobbe number is a measure of the energy delivery rate for appliances that use orifice- or pressure-based fuel metering. The effect of Wobbe number on pollutant emissions from residential water heaters was evaluated in controlled experiments. Experiments were conducted on eight storage water heaters, including five with “ultra low-NO{sub X}” burners, and four on-demand (tankless) water heaters, all of which featured ultra low-NO{sub X} burners. Pollutant emissions were quantified as air-free concentrations in the appliance flue and fuel-based emission factors in units of nanogram of pollutant emitter per joule of fuel energy consumed. Emissions were measured for carbon monoxide (CO), nitrogen oxides (NO{sub X}), nitrogen oxide (NO), formaldehyde and acetaldehyde as the water heaters were operated through defined operating cycles using fuels with varying Wobbe number. The reference fuel was Northern California line gas with Wobbe number ranging from 1344 to 1365. Test fuels had Wobbe numbers of 1360, 1390 and 1420. The most prominent finding was an increase in NO{sub X} emissions with increasing Wobbe number: all five of the ultra low-NO{sub X} storage water heaters and two of the four ultra low-NO{sub X} on-demand water heaters had statistically discernible (p<0.10) increases in NO{sub X} with fuel Wobbe number. The largest percentage increases occurred for the ultra low-NO{sub X} water heaters. There was a discernible change in CO emissions with Wobbe number for all four of the on-demand devices tested. The on-demand water heater with the highest CO emissions also had the largest CO increase with increasing fuel Wobbe number.

Rapp, VH; Singer, BC

2014-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "hydronic space heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Performance of a Heat Pump Water Heater in the Hot-Humid Climate, Windermere, Florida (Fact Sheet)  

SciTech Connect (OSTI)

Over recent years, heat pump water heaters (HPWHs) have become more readily available and more widely adopted in the marketplace. For a 6-month period, the Building America team Consortium for Advanced Residential Buildings monitored the performance of a GE Geospring HPWH in Windermere, Florida. The study found that the HPWH performed 144% more efficiently than a traditional electric resistance water heater, saving approximately 64% on water heating annually. The monitoring showed that the domestic hot water draw was a primary factor affecting the system's operating efficiency.

Metzger, C.; Puttagunta, S.; Williamson, J.

2013-11-01T23:59:59.000Z

322

National Solar Water Heater Workshop Present at DOE Region V meeting for managers of State Energy Extension Service and State Energy Conservation Plan, March 18-19, 1981  

SciTech Connect (OSTI)

After a brief description of the National Solar Water Heater Workshop and some comments by users of the solar water heater, the hardware supplier handbook is presented. The performance expected of a hardware supplier is described, solar system components and their specifications are listed, and information is provided to assist the hardware supplier in obtaining necessary materials. (LEW)

Mumma, S.A.; Marinello, M.G.

1981-01-01T23:59:59.000Z

323

The Integration of Cogeneration and Space Cooling  

E-Print Network [OSTI]

associated space cool- ing is essentially cost free. FIGURE B In hot and humid climates, both air conditioning and humidity control are required. The thermal out- put of a cogeneration unit provides the heat neces- sary to power an absorption chiller... absorption chiller/heaters are in operation within the U.S.; 10,000 tons are oper- ating in the Gulf Coast, a hot and humid climate area. Cogeneration saw a resurgence in the early 1980s, but its growth was limited mostly to in- dustrial plants...

Phillips, J.

1987-01-01T23:59:59.000Z

324

Building America Technology Solutions for New and Existing Homes: Multifamily Central Heat Pump Water Heaters (Fact Sheet)  

Broader source: Energy.gov [DOE]

To evaluate the performance of central heat pump water heaters for multifamily applications, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California, for 16 months.

325

Experimental study of heat transfer in an electric arc gas heater with vortex stabilization of the discharge  

Science Journals Connector (OSTI)

The results of an experimental investigation into heat transfer in the discharge chamber of an electric-arc gas heater are presented. For the anode...an=f(I, d), St=f(l/d, Re, N/GH0). The energy losses in the bas...

V. L. Sergeev

1971-01-01T23:59:59.000Z

326

Twenty-year progress report on the Copper Development Association do-it-yourself solar swimming pool heating manual and on the associated prototype heater  

SciTech Connect (OSTI)

A prototype do-it-yourself solar swimming pool heater was built of copper parts in 1973, combining the solar collector and a copper roof of the flat seam type. It has now heated a pool in Pasadena, California successfully for over 20 years. During those years the associated do-it-yourself manual has been distributed to about 100,000 readers, who have used to make an unknown number of heaters. Some have used the manual as the basis for a business, building repeated customer heater installations. The present paper represents a progress report.

De Winter, F. (Altas Corp., Santa Cruz, CA (United States))

1994-07-01T23:59:59.000Z

327

Building America Technology Solutions for New and Existing Homes: Field Performance of Heat Pump Water Heaters in the Northeast (Fact Sheet)  

Broader source: Energy.gov [DOE]

In this project, the Consortium for Advanced Residential Buildings evaluated three newly released heat pump water heater products in order to provide publicly available field data on these products.

328

Performance testing and Bayesian Reliability Analysis of small diameter, high power electric heaters for the simulation of nuclear fuel rod temperatures  

E-Print Network [OSTI]

proposed full test using prototypic mixed-oxide fuel (MOX) containing plutonium from converted nuclear weapons. Bayesian reliability analysis methods were used to determine the expected heater failure rate because of the expected short test duration...

O'Kelly, David Sean

2012-06-07T23:59:59.000Z

329

Chapter 26 - The Oxyfuel Baseline: Revamping Heaters and Boilers to Oxyfiring by Cryogenic Air Separation and Flue Gas Recycle  

Science Journals Connector (OSTI)

This feasibility study involves the potential application of oxyfuel technology on a refinery-wide basis at the BP Grangemouth unit in Scotland. A total of seven boilers and 13 process heaters of various types, burning a mixture of refinery fuel gas and fuel oil resulting in the production of approximately 2.0 million tonnes per annum of CO2, form the basis of this study.

Rodney Allam; Vince White; Neil Ivens; Mark Simmonds

2005-01-01T23:59:59.000Z

330

Combustion air preheating for refinery heaters using plate-type heat exchangers  

SciTech Connect (OSTI)

Combustion air preheating by recovering heat from combustion gases is a cost effective method of increasing the overall thermal efficiency of the refining and petrochemical processes. This paper presents the advantages of the plate-type air preheaters made of smooth plates without extended surfaces. These exchangers provide a relatively high heat transfer coefficient at a relatively low pressure drop, resulting in a flexible and compact design. The air preheater design can easily be integrated into the heater design. Top mounting with natural draft becomes possible for many applications, eliminating the need for I.D. fan and expensive ductwork. The economical extent of heat recovery function of the fuel fired is presented based on practical experience. The use of porcelain enameled (glass coated) plates and of stainless steel materials allows the operation of the air preheater below the acidic and water dew point. Finally the paper presents the experience of the Canadian refineries and petrochemical plants with plate-type heat exchangers used for combustion air preheating.

Dinulescu, M.

1987-01-01T23:59:59.000Z

331

Short term performance comparisons between a solar thermosyphon water heater and two numerical models  

SciTech Connect (OSTI)

An experimental study of a solar thermosyphon domestic water heater was conducted in the indoor solar simulator facility at Colorado State University (Bickford, 1994). The system consisted of a closed-loop collector circuit filled with propylene glycol and water solution and a horizontal storage tank with an annular tank-in-tank heat exchanger. Short-term irradiated tests with and without timed draws were performed to assess overall performance and monitor collector flow rate, storage tank stratification, and heat exchanger temperature distribution. The measured performance was compared with the ``standard`` thermosyphon model in TRNSYS 13.1 (transient system simulation program). A revised TRNSYS model was developed by Graham Morrison at the University of New South Wales, Australia. The revised model specifically addressed the horizontal tank, closed-loop configuration. The standard TRNSYS version predicted solar gain within 17% of the measured values and differed dramatically from experimental collector temperatures, closed-loop flow rate, and tank stratification. This is not surprising since this model does not include the tank and tank heat exchanger. The revised TRNSYS model agreed more closely with experimental results. It predicted closed-loop flow at 8% lower than observed flow and collector temperature rise that was higher than the observed flow by approximately the same amount, resulting in extremely accurate prediction of collector output energy. Losses from the storage tank and piping were significantly underpredicted in both models, however.

Bickford, C.; Hittle, D.C. [Colorado State Univ., Fort Collins, CO (United States). Solar Energy Applications Lab.

1995-11-01T23:59:59.000Z

332

ADVANCED OXYFUEL BOILERS AND PROCESS HEATERS FOR COST EFFECTIVE CO{sub 2} CAPTURE AND SEQUESTRATION  

SciTech Connect (OSTI)

This annual technical progress report summarizes the work accomplished during the first year of the program, January-December 2002, in the following task areas: Task 1--Conceptual Design, Task 2--Laboratory Scale Evaluations, Task 3--OTM Development, Task 4--Economic Evaluation and Commercialization Planning and Task 5--Program Management. The program has experienced significant delays due to several factors. The budget has also been significantly under spent. Based on recent technical successes significant future progress is expected. A number of concepts for integrating Oxygen Transport Membranes (OTMs) into boilers and process heaters to facilitate oxy-fuel combustion have been proposed. A detailed modeling plan has been proposed and early modeling work has focused on developing spreadsheet based models for quick engineering calculations. Combustion reactor laboratory scale evaluations efforts have been delayed due to the closing of Praxair's Tarrytown facility in December 2001. Experimental facilities and personnel have been relocated to Praxair's facility in Tonawanda. The facilities have recently been re-commissioned. Work with the OTM development task has also been delayed as early material selections were discarded. More recently, more promising OTM material compositions have been identified. Economic evaluation commenced. Information was acquired that quantified the attractiveness of the advanced oxygen-fired boiler. CO{sub 2} capture and compression are still estimated to be much less than $10/ton carbon.

David R. Thompson; Lawrence E. Bool; G. Maxwell Christie

2003-07-01T23:59:59.000Z

333

ADVANCED OXYFUEL BOILERS AND PROCESS HEATERS FOR COST EFFECTIVE CO2 CAPTURE AND SEQUESTRATION  

SciTech Connect (OSTI)

This annual technical progress report summarizes the work accomplished during the second year of the program, January-December 2003, in the following task areas: Task 1--Conceptual Design, Task 2--Laboratory Scale Evaluations, Task 3--OTM Development, Task 4--Economic Evaluation and Commercialization Planning and Task 5--Program Management. The program has experienced significant delays due to several factors. The budget has also been significantly under spent. Based on recent technical successes and confirmation of process economics, significant future progress is expected. Concepts for integrating Oxygen Transport Membranes (OTMs) into boilers and process heaters to facilitate oxy-fuel combustion have been investigated. OTM reactor combustion testing was delayed to insufficient reliability of the earlier OTM materials. Substantial improvements to reliability have been identified and testing will recommence early in 2004. Promising OTM material compositions and OTM architectures have been identified that improve the reliability of the ceramic elements. Economic evaluation continued. Information was acquired that quantified the attractiveness of the advanced oxygen-fired boiler. CO{sub 2} capture and compression are still estimated to be much less than $10/ton CO{sub 2}.

John Sirman; Leonard Switzer; Bart van Hassel

2004-06-01T23:59:59.000Z

334

Thermal performance analysis of a direct-expansion solar-assisted heat pump water heater  

Science Journals Connector (OSTI)

A direct-expansion solar-assisted heat pump water heater (DX-SAHPWH) is described, which can supply hot water for domestic use during the whole year. The system mainly employs a bare flat-plate collector/evaporator with a surface area of 4.2 m2, an electrical rotary-type hermetic compressor, a hot water tank with the volume of 150 L and a thermostatic expansion valve. R-22 is used as working fluid in the system. A simulation model based on lumped and distributed parameter approach is developed to predict the thermal performance of the system. Given the structure parameters, meteorological parameters, time step and final water temperature, the numerical model can output operational parameters, such as heat capacity, system COP and collector efficiency. Comparisons between the simulation results and the experimental measurements show that the model is able to give satisfactory predictions. The effect of various parameters, including solar radiation, ambient temperature, wind speed and compressor speed, has been analyzed on the thermal performance of the system.

X.Q. Kong; D. Zhang; Y. Li; Q.M. Yang

2011-01-01T23:59:59.000Z

335

Development of Environmentally Benign Heat Pump Water Heaters for the US Market  

SciTech Connect (OSTI)

Improving energy efficiency in water heating applications is important to the nation's energy strategies. Water heating in residential and commercial buildings accounts for about 10% of U.S. buildings energy consumption. Heat pump water heating (HPWH) technology is a significant breakthrough in energy efficiency, as an alternative to electric resistance water heating. Heat pump technology has shown acceptable payback period with proper incentives and successful market penetration is emerging. However, current HPWH require the use of refrigerants with high Global Warming Potential (GWP). Furthermore, current system designs depend greatly on the backup resistance heaters when the ambient temperature is below freezing or when hot water demand increases. Finally, the performance of current HPWH technology degrades greatly as the water set point temperature exceeds 330 K. This paper presents the potential for carbon dioxide, CO2, as a natural, environmentally benign alternative refrigerant for HPWH technology. In this paper, we first describe the system design, implications and opportunities of operating a transcritical cycle. Next, a prototype CO2 HPWH design featuring flexible component evaluation capability is described. The experimental setup and results are then illustrated followed by a brief discussion on the measured system performance. The paper ends with conclusions and recommendations for the development of CO2 heat pump water heating technology suitable for the U.S. market.

Abdelaziz, Omar [ORNL] [ORNL; Wang, Kai [ORNL] [ORNL; Vineyard, Edward Allan [ORNL] [ORNL; Roetker, Jack [General Electric - Appliance Park] [General Electric - Appliance Park

2012-01-01T23:59:59.000Z

336

Building America Technology Solutions for New and Existing Homes: Performance of a Heat Pump Water Heater in the Hot-Humid Climate, Windermere, Florida (Fact Sheet)  

Broader source: Energy.gov [DOE]

For a 6-month period, the Building America team Consortium for Advanced Residential Buildings monitored the performance of a heat pump water heater in Windermere, Florida. The study found that the HPWH performed 144% more efficiently than a traditional electric resistance water heater, saving approximately 64% on water heating annually. The monitoring showed that the domestic hot water draw was a primary factor affecting the system's operating efficiency.

337

Development of minimum efficiency standards for large capacity air conditioners, and commercial water heaters, refrigerators, and freezers. Final report  

SciTech Connect (OSTI)

The California Energy Resources Conservation and Development Commission has promulgated appliance energy efficiency standards and energy conservation standards for new construction with the objective of reducing energy consumption in the State of California. The following appliance categories are specifically addressed: large capacity air conditioners; commercial water heaters; and commercial refrigerators and freezers. The tasks that have been performed include: an energy use pattern study for the subject equipment; an examination of the size distribution of commercial air conditioning equipment; an examination of the different types of commercial air conditioning systems; an evaluation of the effectiveness of economizers in reducing commercial air conditioning system energy consumption in California; an examination of the effects of oversizing commercial air conditioners; a detailed study of supermarket refrigeration and air conditioning equipment; an evaluation of the economic feasibility of utilizing air conditioner waste heat to heat water; an assessment of the applicability of existing test procedures for small water heaters to large water heaters; and a brief investigation of the marketing and distribution systems for air conditioning and refrigeration equipment. Results of the efforts are described.

Merrill, P.S.; Rettberg, R.J.; Erickson, R.C.; Toor, J.S.

1980-05-01T23:59:59.000Z

338

Space Microbiology  

Science Journals Connector (OSTI)

...2010 ARTICLE REVIEWS Space Microbiology Gerda Horneck...2005. Metagenomic libraries from uncultured microorganisms...environments. Gravit. Space Biol. 18: 85-86...rendering plant process. Public Health Rep. 72: 176...bacteriophage. Life Sci. Space Res. 13: 143-149...

Gerda Horneck; David M. Klaus; Rocco L. Mancinelli

2010-03-01T23:59:59.000Z

339

Combi Systems for Low Load homes  

Broader source: Energy.gov (indexed) [DOE]

text styles text styles Combi Systems for Low Load Homes Center for Energy and Environment, NorthernSTAR, Ben Schoenbauer * Low load homes are more common than ever. * Typical space heating and DHW equipment have capacities larger than necessary * A single heating plant could provide high efficiency heat at lower costs, increased durability and improved combustion safety Context Technical Approach * A condensing water heater and hydronic air handler will used to provide space and water heating loads in almost 300 weatherized homes. * System specifications, sizing, and installation optimization guidelines were all developed. * Contractor capability was developed in MN market, but may not be developed in all local. 4 Recommended Guidance * Determine peak load on system: - Space heating design load (ie 40,000 Btu/hr)

340

2014-10-14 Issuance: Test Procedures and Energy Conservation Standards for Residential Solar Water Heaters; Request for Information  

Broader source: Energy.gov [DOE]

This document is a pre-publication Federal Register request for information regarding test procedures and energy conservation standards for residential solar water heaters, as issued by the Deputy Assistant Secretary for Energy Efficiency on October 14, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

Note: This page contains sample records for the topic "hydronic space heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Techno-economic assessment of substituting natural gas based heater with thermal energy storage system in parabolic trough concentrated solar power plant  

Science Journals Connector (OSTI)

Abstract Parabolic-trough (PT) concentrated solar power (CSP) plants are very vulnerable to daily fluctuations in solar radiation. This dependence can be mitigated through a hybridization of solar energy with natural gas based heaters that supply thermal energy during the night or whenever solar irradiance level is dimmed. However, there is more sustainable way for CSP plants to avoid power-generation-outages caused by transient weather conditions, i.e. installation of thermal energy storage (TES). Such a system stores surplus thermal energy provided by solar field during sunny hours and discharges it when the sun is not available. Shams-1 PT plant in Madinat-Zayed, United-Arab-Emirates (UAE) has two natural gas based components, i.e. steam-booster heater and heat transfer fluid (HTF) heater. In the current study, model of Shams-1 was developed and analyzed in the System Advisor Model (SAM) software. It has been attempted to replace the HTF heater with TES. A parametric study has been conducted to determine the size of the TES as well as the solar field such that the specified power target demand would be satisfied. The results of the parametric analysis showed that TES can't completely replace the HTF heater, within reasonable sizes. Nevertheless, consequent simulations depicts that TES increases the capacity factor on one hand and decreases fuel consumption on the other hand.

V. Poghosyan; Mohamed I. Hassan

2015-01-01T23:59:59.000Z

342

Innovation Spaces  

E-Print Network [OSTI]

Innovation ecosystems today are the lifeblood or the great hope of many major economies, but at the heart of these ecosystems, there are places and spaces. Silicon Valley is not just a place, but a cluster of spaces where ...

Schneider-Sikorsky, Patrick A

2014-01-01T23:59:59.000Z

343

Techno-economic evaluation of a ventilation system assisted with exhaust air heat recovery, electrical heater and solar energy  

Science Journals Connector (OSTI)

Abstract The energy consumed to condition fresh air is considerable, particularly for the buildings such as cinema, theatre or gymnasium saloons. The aim of the present study is to design a ventilation system assisted with exhaust air heat recovery unit, electrical heater and stored solar energy, then to make an economical analysis based on life cycle cost (LCC) to find out its payback period. The system is able to recover thermal energy of exhaust air, store solar energy during the sunlight period and utilize it in the period between 17:00 and 24:00 h. The transient behaviour of the system is simulated by the TRNSYS 16 software for winter period from 1st of November to 31st of March for Izmir city of Turkey. The obtained results show that the suggested ventilation system reduces energy consumption by 86% compared to the conventional ventilation system in which an electrical heater is used. The payback period of the suggested system is found to be 5 years and 8 months which is a promising result in favour of the solar energy usage in building ventilation systems.

Gamze Ozyogurtcu; Moghtada Mobedi; Baris Ozerdem

2014-01-01T23:59:59.000Z

344

Performance and economic evaluation of the seahorse natural gas hot water heater conversion at Fort Stewart. Final report  

SciTech Connect (OSTI)

The Federal government is the largest single energy consumer in the United States with consumption of nearly 1.5 quads/year of energy (10{sup 15} quad = 1015 Btu) and cost valued at nearly $10 billion annually. The US Department of Energy`s (DOE) Federal Energy Management Program (FEMP) supports efforts to reduce energy use and associated expenses in the Federal sector. One such effort, the New Technology Demonstration Program (NTDP) seeks to evaluate new energy -- saving US technologies and secure their more timely adoption by the US government. Pacific Northwest Laboratory (PNL) is one of four DOE laboratories that participate in the New Technologies Demonstration Program, providing technical expertise and equipment to evaluate new, energy-saving technologies being studied under that program. This report provides the results of a field evaluation that PNL conducted for DOE/FEMP with funding support from the US Department of Defense (DoD) Strategic Environmental Research and Development Program (SERDP) to examine the performance of 4 candidate energy-saving technology-a water heater conversion system to convert electrically powered water heaters to natural gas fuel. The unit was installed at a single residence at Fort Stewart, a US Army base in Georgia, and the performance was monitored under the NTDP. Participating in this effort under a Cooperative Research and Development Agreement (CRADA) were Gas Fired Products, developers of the technology; the Public Service Company of North Carolina; Atlanta Gas Light Company; the Army Corps of Engineers; Fort Stewart; and Pacific Northwest Laboratory.

Winiarski, D.W.

1995-12-01T23:59:59.000Z

345

CenterPoint Energy - Residential Gas Heating Rebates | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

CenterPoint Energy - Residential Gas Heating Rebates CenterPoint Energy - Residential Gas Heating Rebates CenterPoint Energy - Residential Gas Heating Rebates < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Appliances & Electronics Water Heating Program Info State Arkansas Program Type Utility Rebate Program Rebate Amount Storage Tank Water Heater: $75 Tankless Water Heater: $500 Forced-Air Furnace: $400 - $600 Forced-Air Furnace (Back-Up System): $125 - $175 Hydronic Heating System: $400 Provider CenterPoint Energy CenterPoint Energy offers gas heating and water heating equipment rebates to its residential customers. Eligible equipment includes furnaces, back-up furnace systems, hydronic heaters, storage water heaters and tankless water heaters. All equipment must meet program requirements for efficiency and

346

Report on International Collaboration Involving the FE Heater and HG-A Tests at Mont Terri  

SciTech Connect (OSTI)

Nuclear waste programs outside of the US have focused on different host rock types for geological disposal of high-level radioactive waste. Several countries, including France, Switzerland, Belgium, and Japan are exploring the possibility of waste disposal in shale and other clay-rich rock that fall within the general classification of argillaceous rock. This rock type is also of interest for the US program because the US has extensive sedimentary basins containing large deposits of argillaceous rock. LBNL, as part of the DOE-NE Used Fuel Disposition Campaign, is collaborating on some of the underground research laboratory (URL) activities at the Mont Terri URL near Saint-Ursanne, Switzerland. The Mont Terri project, which began in 1995, has developed a URL at a depth of about 300 m in a stiff clay formation called the Opalinus Clay. Our current collaboration efforts include two test modeling activities for the FE heater test and the HG-A leak-off test. This report documents results concerning our current modeling of these field tests. The overall objectives of these activities include an improved understanding of and advanced relevant modeling capabilities for EDZ evolution in clay repositories and the associated coupled processes, and to develop a technical basis for the maximum allowable temperature for a clay repository. The R&D activities documented in this report are part of the work package of natural system evaluation and tool development that directly supports the following Used Fuel Disposition Campaign (UFDC) objectives: ? Develop a fundamental understanding of disposal-system performance in a range of environments for potential wastes that could arise from future nuclear-fuel-cycle alternatives through theory, simulation, testing, and experimentation. ? Develop a computational modeling capability for the performance of storage and disposal options for a range of fuel-cycle alternatives, evolving from generic models to more robust models of performance assessment. For the purpose of validating modeling capabilities for thermal-hydro-mechanical (THM) processes, we developed a suite of simulation models for the planned full-scale FE Experiment to be conducted in the Mont Terri URL, including a full three-dimensional model that will be used for direct comparison to experimental data once available. We performed for the first time a THM analysis involving the Barcelona Basic Model (BBM) in a full three-dimensional field setting for modeling the geomechanical behavior of the buffer material and its interaction with the argillaceous host rock. We have simulated a well defined benchmark that will be used for codeto- code verification against modeling results from other international modeling teams. The analysis highlights the complex coupled geomechanical behavior in the buffer and its interaction with the surrounding rock and the importance of a well characterized buffer material in terms of THM properties. A new geomechanical fracture-damage model, TOUGH-RBSN, was applied to investigate damage behavior in the ongoing HG-A test at Mont Terri URL. Two model modifications have been implemented so that the Rigid-Body-Spring-Network (RBSN) model can be used for analysis of fracturing around the HG-A microtunnel. These modifications are (1) a methodology to compute fracture generation under compressive stress conditions and (2) a method to represent anisotropic elastic and strength properties. The method for computing fracture generation under compressive load produces results that roughly follow trends expected for homogeneous and layered systems. Anisotropic properties for the bulk rock were represented in the RBSN model using layered heterogeneity and gave bulk material responses in line with expectations. These model improvements were implemented for an initial model of fracture damage at the HG-A test. While the HG-A test model results show some similarities with the test observations, differences between the model results and observations remain.

Houseworth, Jim; Rutqvist, Jonny; Asahina, Daisuke; Chen, Fei; Vilarrasa, Victor; Liu, Hui-Hai; Birkholzer, Jens

2013-11-06T23:59:59.000Z

347

Progress toward the evolution of a Stirling Space Engine  

SciTech Connect (OSTI)

Following the successful testing of the 25 kWe Space Power Demonstrator (SPD) engine in 1985, a Stirling Space Engine (SSE) technology advancement program was initiated. The program`s objective was to advance free-piston Stirling engine/alternator technology sufficiently so that a Stirling engine system may become a viable candidate for space power applications. Evolution of the SSE technology is planned to occur at three different engine heater temperature levels: 650, 1050, and 1300 K. These temperatures define three phases of technology development with the first phase involving the 650 K SPD engine. Technology development of the 650 K engine and preliminary design of the 1050 K engine will be discussed in this paper.

Alger, D.L. [Lewis Research Center, Cleveland, OH (United States)

1994-09-01T23:59:59.000Z

348

Space Nuclear  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

a "Group Achievement Award" by the National Aeronautics and Space Administration (NASA) for their efforts as part of the New Horizons mission launch in 2006. More....

349

Review of experiments to evaluate the ability of electrical heater rods to simulate nuclear fuel rod behavior during postulated loss-of-coolant accidents in light water reactors  

SciTech Connect (OSTI)

Issues related to using electrical fuel rod simulators to simulate nuclear fuel rod behavior during postulated loss-of-coolant accident (LOCA) conditions in light water reactors are summarized. Experimental programs which will provide a data base for comparing electrical heater rod and nuclear fuel rod LOCA responses are reviewed.

McPherson, G D; Tolman, E L

1980-01-01T23:59:59.000Z

350

Flow boiling enhancement on a horizontal heater using carbon nanotube coatings N. Singh, V. Sathyamurthy, W. Peterson, J. Arendt, D. Banerjee *  

E-Print Network [OSTI]

mechanisms (thermal and hydro-dy- namic interactions). Apart from the fluid and heater thermo-phys- ical enhancement has been explored in the literature using micro-scale as well as macro-scale features in round have also been reported in the litera- ture such as plate fin surface, micro-fins, twisted-tape inserts

Banerjee, Debjyoti

351

Experimental investigation of the night heat losses of hot water storage tanks in thermosyphon solar water heaters  

Science Journals Connector (OSTI)

The effects of night heat losses on the performance of thermosyphon solar water heaters have been experimentally examined. Three typical thermosyphon solar water heating systems with different storage tank sizes were tested by utilising the method suggested by ISO 9459-2:95. The results were analysed to quantify the night heat losses and to investigate the effect that these may have on the system daily performance. Analysis of the results showed that a linear behavior of the heat losses with the night mean ambient temperature exists. The correlation coefficients of the linearity for the three systems under consideration range from 0.93 to 0.97 with the losses reaching almost 8000 kJ at a mean ambient air temperature of 10 °C. This value represents a significant percentage of the daily collected energy making the night losses one of the most important sources of energy loss in thermosyphonic systems.

Ioannis Michaelides; Polyvios Eleftheriou; George A. Siamas; George Roditis; Paraskevas Kyriacou

2011-01-01T23:59:59.000Z

352

Solar-assisted auto-cascade heat pump cycle with zeotropic mixture R32/R290 for small water heaters  

Science Journals Connector (OSTI)

Abstract In this study, a novel solar-assisted auto-cascade heat pump cycle (SAHPC) operating with the zeotropic mixture of R32/R290 for small water heaters is proposed. In the SAHPC system, a cascade heat exchanger (CHEX) associated with a phase separator is used to achieve auto cascade cycle and enhance the overall system performance. The performances of the SAHPC are evaluated by using the developed mathematical model, and then compared with the conventional air-sourced heat pump cycle (CAHPC). Simulation results show the SAHPC has 4.23–9.85% and 4.37–9.68% improvements in COP and volumetric heating capacity compared with those of the CAHPC, respectively, under the same operating conditions. However, the improvement of performance of this novel cycle largely depends on the absorbing heat ratio and the zeotropic composition. It is expected that this new cycle will be beneficial to developing dual-source coupled heat pump applications.

Xiaolong Lv; Gang Yan; Jianlin Yu

2015-01-01T23:59:59.000Z

353

Auto-Calibration and Control Strategy Determination for a Variable-Speed Heat Pump Water Heater Using Optimization  

SciTech Connect (OSTI)

This paper introduces applications of the GenOpt optimizer coupled with a vapor compression system model for auto-calibration and control strategy determination towards the development of a variable-speed ground-source heat pump water heating unit. The GenOpt optimizer can be linked with any simulation program using input and output text files. It effectively facilitates optimization runs. Using our GenOpt wrapper program, we can flexibly define objectives for optimizations, targets, and constraints. Those functionalities enable running extensive optimization cases for model calibration, configuration design and control strategy determination. In addition, we describe a methodology to improve prediction accuracy using functional calibration curves. Using the calibrated model, we investigated control strategies of the ground-source heat pump water heater, considering multiple control objectives, covering the entire operation range.

Shen, Bo [ORNL] [ORNL; Abdelaziz, Omar [ORNL] [ORNL; Rice, C Keith [ORNL] [ORNL

2012-01-01T23:59:59.000Z

354

Track A - Energy Systems Innovations | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Track A - Energy Systems Innovations Track A - Energy Systems Innovations Track A - Energy Systems Innovations Presentations from Track A, Energy Systems Innovations, of the U.S. Department of Energy Building America program's 2012 Residential Energy Efficiency Stakeholder Meeting are provided below as Adobe Acrobat PDFs. These presentations for this track covered the following topics: Space Conditioning and Hot Water Systems; Options for Insulating Foundations; Mini-split Systems; Heat Pump Water Heaters; Hydronic Heating Control Strategies; and Exterior Insulation Breakthroughs. contractor_accept.pdf testing_water_heating.pdf combined_tankless_wh.pdf upgrade_below_grade.pdf assessing_priorities.pdf industry_perspective.pdf ductless_hp_factory.pdf ductless_heat_pumps_nw.pdf field_eval_hpwh.pdf

355

Cascade Natural Gas - Conservation Incentives for Existing Homes |  

Broader source: Energy.gov (indexed) [DOE]

Existing Homes Existing Homes Cascade Natural Gas - Conservation Incentives for Existing Homes < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Sealing Your Home Ventilation Heating & Cooling Commercial Heating & Cooling Heating Appliances & Electronics Water Heating Program Info State District of Columbia Program Type Utility Rebate Program Rebate Amount Floor Insulation: $0.45 per sq. ft. Wall Insulation: $0.40 per sq. ft. Ceiling or Attic Insulation: $0.25 per sq. ft. High Efficiency Natural Gas Furnace: $150 Duct Sealing: $150 High Efficiency Natural Gas Furnace and Duct Sealing: $400 High Efficiency Natural Gas Hearth: $70 Conventional Natural Gas Water Heater: $40 Combination Domestic Water/Hydronic Space Heating System (using Tankless

356

Ductless, Mini-Split Heat Pump Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Ductless, Mini-Split Heat Pump Basics Ductless, Mini-Split Heat Pump Basics Ductless, Mini-Split Heat Pump Basics August 19, 2013 - 11:04am Addthis Ductless, mini-split-system heat pumps (mini splits), as their name implies, do not have ducts. Therefore, they make good retrofit add-ons to houses or buildings with "non-ducted" heating systems, such as hydronic (hot water heat), radiant panels, and space heaters (wood, kerosene, propane). They can also be a good choice for room additions, where extending or installing distribution ductwork is not feasible. How Ductless, Mini-Split Heat Pumps Work Like standard air-source heat pumps, mini splits have two main components: an outdoor compressor/condenser, and an indoor air-handling unit. A conduit, which houses the power cable, refrigerant tubing, suction tubing,

357

Page not found | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

71 - 10380 of 28,905 results. 71 - 10380 of 28,905 results. Download Track A - Energy Systems Innovations Presentations from Track A, Energy Systems Innovations, of the U.S. Department of Energy Building America program's 2012 Residential Energy Efficiency Stakeholder Meeting are provided below as Adobe Acrobat PDFs. These presentations for this track covered the following topics: Space Conditioning and Hot Water Systems; Options for Insulating Foundations; Mini-split Systems; Heat Pump Water Heaters; Hydronic Heating Control Strategies; and Exterior Insulation Breakthroughs. http://energy.gov/eere/downloads/track-energy-systems-innovations Download EA-1456: Final Environmental Assessment Cheyenne-Miracle Mile and Ault-Cheyenne Transmission Line Rebuild Project, Loveland, Colorado http://energy.gov/nepa/downloads/ea-1456-final-environmental-assessment

358

Ductless, Mini-Split Heat Pumps | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Ductless, Mini-Split Heat Pumps Ductless, Mini-Split Heat Pumps Ductless, Mini-Split Heat Pumps June 24, 2012 - 4:19pm Addthis What does this mean for me? You can take advantage of the fact that -- unlike earlier versions -- newer models of ductless mini-split heat pumps operate effectively in cold temperatures. If you are building an addition or doing a major remodel and your home does not have heating and cooling ducts, a ductless mini-split heat pump may be a cost-effective, energy-efficient choice. Ductless, mini-split-system heat pumps (mini splits) make good retrofit add-ons to houses with "non-ducted" heating systems, such as hydronic (hot water heat), radiant panels, and space heaters (wood, kerosene, propane). They can also be a good choice for room additions where extending or

359

Preliminary characterization of deposits formed on super heater surfaces in an FBC-boiler fired with municipal solid waste  

SciTech Connect (OSTI)

A preliminary study of the chemical and mineralogical composition of deposits formed on super heater tubes in a CFB fired with 100% sorted municipal solid waste has been carried out. Samples of deposits formed on both the windward and leeward side of the tubes were analyzed with the aim to identify the ash species involved in fouling and to get information about chemical interaction between the tube alloys and the deposits. The metal temperatures in the super heater region were in the range 460--540 C during the sampling period. The identified deposit constituents show the importance of alkali metal chlorides in the deposit forming process. Alkali metal chlorides (NaCl and KCl) were found both on the windward side deposits and on the leeward side. Other components were CaSO{sub 4}m MgO and some oxide and phosphate compounds. Some of these components have probably been formed through reaction between the alloy and the deposit but more work will be done in co-operation with the Competence Centre for High Temperature Corrosion, Sweden in order to elucidate such interactions and the influence of deposits on the corrosion rates. The presence of chlorides on an alloyed steel at the temperatures used here may cause a rapid deterioration of the protective oxide scale on the alloy. First, a layer of molten chlorides may dissolve species from the protective oxide layer on the steel tube. Secondly, corrosion may occur according to a mechanism called active oxidation, which involves diffusion of chlorine to the metal/oxide interface and breakdown of the scale due to formation of new products.

Steenari, B.M.; Lindqvist, O.; Andersson, B.A.

1999-07-01T23:59:59.000Z

360

Full-scale cold-flow modelling of the SRC-I slurry fired heater at Creare, Inc. mixing and 1/sup 0/ downslope studies  

SciTech Connect (OSTI)

One of the major pieces of equipment in the SRC-I Demonstration Plant is the slurry fired heater. Because of the absence of any plant data at comparable combinations of operating severity, a cold-flow modelling experimental program was initiated at Creare, Inc. The first phase of the test program confirmed the fired heater design and established reliable boundaries of flow rates for proper operation of the fired heater. An experimental setup was designed and built at Creare to duplicate the piping arrangement and flow conditions of the fired heater. The pipe dimensions, flow rates, and fluid properties were selected to minimize areas of scale-up and extrapolation. This follow-up test program was developed to resolve concerns raised from the observations made in the first phase. Tests were conducted to establish the extent of mixing between the liquid carpet and the fast-moving liquid slugs above it. The other segment of the test program was designed to develop the flow regime and pressure drop data in the 1/sup 0/ downslope configuration. The results demonstrated a significant amount of mixing between the liquid carpet and the liquid slugs for water and the 400-cP fluid at the design flow conditions. The extent of mixing improved with increasing liquid and gas velocities and decreasing liquid viscosities. Adequate mixing was observed at liquid flow rates as low as 50% of the design flow conditions. Slug flow was observed at design conditions in the 1/sup 0/ downslope configuration. Although adequate mixing is expected in heater pipes, different techniques should be investigated to improve the extent of mixing, especially near the transition boundary. 4 references, 5 figures, 8 tables.

Mehta, D.C.

1984-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "hydronic space heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Space Weather  

E-Print Network [OSTI]

magnetic field that enshrouds Earth is subject to a continuing low dose of galactic cosmic radiation. The best available estimates predict that exposure to such radiation for as little as a year may-inducing radiation in space. Eugene N. Parker 18 August 2005 Any space traveler far removed from the protective

Shepherd, Simon

362

Design and Control of Hydronic Radiant Cooling Systems  

E-Print Network [OSTI]

141 Appendix B: David Brower Center building modelingBrower Center building modeling information Construction anda standard building energy modeling platform. Communication

Feng, Jingjuan Dove

2014-01-01T23:59:59.000Z

363

Building America Expert Meeting: Multifamily Hydronic and Steam...  

Energy Savers [EERE]

This expert meeting was conducted on July 13, 2011 by the ARIES Collaborative in New York City. The topic of this expert meeting was cost-effective controls and distribution...

364

Multi-Source Hydronic Heat Pump System Performance Test Bed  

E-Print Network [OSTI]

pump unit) with a central chilled water storage tank. The MSHHP system uses significantly less energy than a conventional HVAC system, and lowers peak demand by shifting required electrical energy consumption to lower-cost, off-peak and mid-peak rates...

Meckler, M.

1984-01-01T23:59:59.000Z

365

Hydronic Heating Coil Versus Propane Furnace, Rehoboth Beach...  

Energy Savers [EERE]

source heat pump (ASHP) with supplemental propane furnace heating. The Building America test house uses the same ASHP unit, but supplemental heat is provided by a combined DHW and...

366

Building America Case Study: Boiler Control Replacement for Hydronical...  

Energy Savers [EERE]

and nighttime setback. In one building, the new controller included a feature to reduce heat when included apartment temperatures exceeded a set point. This Web-enabled system...

367

Building America Case Study: Balancing Hydronic Systems in Multifamily...  

Energy Savers [EERE]

The buildings become under- and over- heated, which causes tenant discomfort and higher energy use intensity. In this project, the U.S. Department of Energy Building America team...

368

Design and Control of Hydronic Radiant Cooling Systems  

E-Print Network [OSTI]

normalized mean bias error SHGC Solar heat gain coefficientwas 2.721 W/(m 2. K) with Glass SHGC at 0.788. The baselinevalue of 2.721 W/m 2 ·K and SHGC of 0.788 and the total area

Feng, Jingjuan Dove

2014-01-01T23:59:59.000Z

369

Design and Control of Hydronic Radiant Cooling Systems  

E-Print Network [OSTI]

air temperature control Supply air temperature from the aircombined with supply water temperature control (Gwerder etflow, variable-supply water temperature control can save up

Feng, Jingjuan Dove

2014-01-01T23:59:59.000Z

370

Space Research  

Science Journals Connector (OSTI)

In the two years since the last SPIE meeting on this topic there has been much activity in both ground and space based interferometry. The author reviews those developments. He also summarizes the Strawman Sci...

G. Burkhardt; U. Esser; H. Hefele; I. Heinrich; W. Hofmann…

1998-01-01T23:59:59.000Z

371

Space Microbiology  

Science Journals Connector (OSTI)

...membranes under conditions of free fall (in a drop tower) and hypergravity (in a centrifuge). This...operation in the International Space Station. SAE technical paper 2006-01-2157. SAE, Warrendale, PA. 225 Rothschild, L., and...

Gerda Horneck; David M. Klaus; Rocco L. Mancinelli

2010-03-01T23:59:59.000Z

372

Texas Gas Service - Commercial Energy Efficiency Rebate Program |  

Broader source: Energy.gov (indexed) [DOE]

Texas Gas Service - Commercial Energy Efficiency Rebate Program Texas Gas Service - Commercial Energy Efficiency Rebate Program Texas Gas Service - Commercial Energy Efficiency Rebate Program < Back Eligibility Commercial Industrial Savings Category Appliances & Electronics Water Heating Program Info State Texas Program Type Utility Rebate Program Rebate Amount Front-loading Clothes Washers: up to $100 Commercial Water Heating System: up to 20% of cost Hydronic Heater: $125 per unit Infra-red Fryers: $400 Convection Ovens: $400 Conveyor Ovens: $400 Infra-red Griddles $200 Booster Heater: $500/unit Texas Gas Service (TGS) offers a range of financial incentives to commercal customers who purchase and install energy efficient commercial equipment. Eligible equipment includes commercial clothes washers, water heaters, hydronic heating systems, ovens, fryers, griddles and booster heaters.

373

Liu and Spitler. Submitted to the 12th International Road Weather Conference 1  

E-Print Network [OSTI]

future weather conditions, especially when geothermal energy is used as the heat source sources can be used for such systems, including boilers, electrical heater, ground water, and ground hydronic bridge snow melting systems using ground source heat pumps (GSHP) or other heat sources has been

374

Heating of a testing room by use of a hydrogen-fueled catalytic heater  

Science Journals Connector (OSTI)

Space heating experiments were carried out using flameless (catalytic) combustion of hydrogen with atmospheric oxygen on Pt and oxide catalyst pads. The heating rate required for warming of a testing room was calculated and material balance equations for oxygen depletion and steam production were derived. The following parameters have been investigated: 1. (a) change of the oxygen and water vapour contents in the testing room in comparison with the calculated values, 2. (b) the established thermal regime in the testing room is discussed in comparison with conventional heating. The following conclusions are drawn: 1. (1) The hydrogen combustion can be adjusted to produce the desired temperature level, 2. li(2) in order to maintain the oxygen concentration at the comfort level, the free ventilation in the room should be supplemented by short, periodic, forced ventilation, 3. (3) the comfort limits of humidity require the condensation of the surplus water vapour by using a suitable device.

J. Mercea; E. Grecu; T. Fodor

1981-01-01T23:59:59.000Z

375

The effect of write current on thermal flying height control sliders with dual heater/insulator elements  

Science Journals Connector (OSTI)

The effect of write induced pole tip protrusion on the magnetic spacing of the head/disk interface has to be taken into consideration as flying heights approach the spacing regime of a few nano-meters. Thermal flying

Hao Zheng; Hui Li; Kensuke Amemiya; Frank E. Talke

2011-06-01T23:59:59.000Z

376

Energy and exergy analysis of a new flat-plate solar air heater having different obstacles on absorber plates  

Science Journals Connector (OSTI)

This study experimentally investigates performance analysis of a new flat-plate solar air heater (SAH) with several obstacles (Type I, Type II, Type III) and without obstacles (Type IV). Experiments were performed for two air mass flow rates of 0.0074 and 0.0052 kg/s. The first and second laws of efficiencies were determined for \\{SAHs\\} and comparisons were made among them. The values of first law efficiency varied between 20% and 82%. The values of second law efficiency changed from 8.32% to 44.00%. The highest efficiency were determined for the SAH with Type II absorbent plate in flow channel duct for all operating conditions, whereas the lowest values were obtained for the SAH without obstacles (Type IV). The results showed that the efficiency of the solar air collectors depends significantly on the solar radiation, surface geometry of the collectors and extension of the air flow line. The largest irreversibility was occurring at the SAH without obstacles (Type IV) collector in which collector efficiency is smallest. At the end of this study, the energy and exergy relationships are delivered for different SAHs.

Ebru Kavak Akpinar; Fatih Koçyi?it

2010-01-01T23:59:59.000Z

377

Experimental energy and exergy analysis of a double-flow solar air heater having different obstacles on absorber plates  

Science Journals Connector (OSTI)

This paper presents an experimental energy and exergy analysis for a novel flat plate solar air heater (SAH) with several obstacles and without obstacles. For increasing the available heat-transfer area may be achieved if air is flowing simultaneously and separately over and under the different obstacle absorbing plates, instead of only flowing either over or under the different obstacle absorbing plates, leading to improved collector efficiency. The measured parameters were the inlet and outlet temperatures, the absorbing plate temperatures, the ambient temperature, and the solar radiation. Further, the measurements were performed at different values of mass flow rate of air and different levels of absorbing plates in flow channel duct. After the analysis of the results, the optimal value of efficiency is middle level of absorbing plate in flow channel duct for all operating conditions and the double-flow collector supplied with obstacles appears significantly better than that without obstacles. At the end of this study, the exergy relations are delivered for different SAHs. The results show that the largest irreversibility is occurring at the flat plate (without obstacles) collector in which collector efficiency is smallest.

Hikmet Esen

2008-01-01T23:59:59.000Z

378

Performance and economic evaluation of the seahorse natural gas hot water heater conversion at Fort Stewart. Interim report, 1994 Summer  

SciTech Connect (OSTI)

The federal government is the largest single energy consumer in the United States cost valued at nearly $10 billion annually. The US Department of Energy`s (DOE) Federal Energy Management Program (FEMP) supports efforts to reduce energy use and associated expenses in the federal sector. One such effort, the New Technology Demonstration Program (NTDP), seeks to evaluate new energy-saving US technologies and secure their more timely adoption by the US government. Pacific Northwest Laboratory (PNL) is one of four DOE laboratories that participate in the New Technologies Demonstration Program, providing technical expertise and equipment to evaluate new, energy-saving technologies being studied under that program. This interim report provides the results of a field evaluation that PNL conducted for DOE/FEMP and the US Department of Defense (DoD) Strategic Environmental Research and Development Program (SERDP) to examine the performance of a candidate energy-saving technology-a hot water heater conversion system to convert electrically heated hot water tanks to natural gas fuel. The unit was installed at a single residence at Fort Stewart, a US Army base in Georgia, and the performance was monitored under the NTDP. Participating in this effort under a Cooperative Research and Development Agreement (CRADA) were Gas Fired Products, developers of the technology; the Public Service Company of North Carolina; Atlanta Gas Light Company; the Army Corps of Engineers; Fort Stewart; and Pacific Northwest Laboratory.

Winiarski, D.W.

1995-01-01T23:59:59.000Z

379

Use of Space Heaters in University Buildings As stated in the University's Health and Safety Policy, the University of Connecticut is  

E-Print Network [OSTI]

building occupants should first contact Facilities Operations Work Order Control (6- 3113) to request assistance in adjusting the temperature of an area. If Facilities Operations personnel determine in accordance with University Laws and By-Laws, General Rules of Conduct for All University Employees

Holsinger, Kent

380

Animated Space  

E-Print Network [OSTI]

activists returning to the Square over thirty years to protest against diverse injustices, including mine closures, nuclear arms escalation, violence against women, Apartheid in South Africa, the war in Iraq and Afghanistan, repression in Palestine... movement, the protests in Southern Europe against austerity, the uprisings in Ukraine, the demonstrations against wasteful state expenditure in Brazil are the emblems of the new politics of insurgency; their rebellious public spaces tangible expression...

Amin, Ash

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hydronic space heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

The effect of write current on thermal flying height control sliders with dual heater/insulator elements  

Science Journals Connector (OSTI)

The effect of write induced pole tip protrusion on the magnetic spacing of the head/disk interface has to be taken into consideration as flying heights approach the spacing regime of a few nano-meters. Thermal flying height control (TFC) sliders are ...

Hao Zheng; Hui Li; Kensuke Amemiya; Frank E. Talke

2011-06-01T23:59:59.000Z

382

Analysis of field-test data from domestic solar-water heaters in the southern United States, period through September 1982  

SciTech Connect (OSTI)

The monitored performance data used here was gathered from 137 solar water heaters. All but 51 are located in Florida. The gathered data accumulated from weekly mailers consists of the following measurements: total gallons of hot water consumed; total kWh of electricity used; total hours the circulating pump operated; hot and cold water temperatures at the top; number of household members at home since last reading; tank thermostat setting and any changes to it; total number of hours that the tank's backup heating element had power available; and problems or comments concerning system operational status or component reliability and maintenance. The data analysis is described and results are presented. (MHR)

Jones, W.M.; Fenner, M.F.

1983-01-01T23:59:59.000Z

383

Dehumidifying water heater  

SciTech Connect (OSTI)

Drawings and specifications are included for the system to heat water for the swimming pool and dehumidify the building of the Glen Cove YMCA. An overview is presented of the Nautica product used in this system. (MHR)

Not Available

1992-08-18T23:59:59.000Z

384

Residential Water Heaters Webinar  

Broader source: Energy.gov [DOE]

Jerone Gagliano presents information on water heating technology for U.S Department of Energy Sustainable Energy Resources for Consumers grant program

385

Improving Fired Heater Efficiency  

E-Print Network [OSTI]

, Oxygen and carbon monoxide can be monitored in the stack gases, Also, a critical tube temperature can be monitored for a limit or an override, When the heat release exceeds the available combustion air being pulled in with the fuel flow... the Fifth Industrial Energy Technology Conference Volume II, Houston, TX, April 17-20, 1983 heat release and furnace draft controller. On this type of furnace, it is advisable to use oxygen and carbon monoxide monitors for warning and burner balancing. A...

Shriver, J. E.

1983-01-01T23:59:59.000Z

386

Immersible solar water heater  

SciTech Connect (OSTI)

The invention consists in an immersible solar heat collecting means capable of being laid at the bottom of a pool where it can be walked upon. The substantially laminar portions of the collector each includes a surface of higher light absorbence than the other side thereof so that by folding or otherwise overlapping and rearranging the various portions a different number of higher light absorbence surfaces can be presented to the sun to heat the water at any particular time. Such an apparatus makes possible the controlled solar heating of a pool.

Caroon, R.S.

1980-12-09T23:59:59.000Z

387

Electric Storage Water Heaters  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

energy can be wasted even when a hot water tap isn't running. This is called standby heat loss. The American Council for an Energy Efficient Economy provides a helpful...

388

Water Heaters (Storage Electric)  

Broader source: Energy.gov [DOE]

The Department of Energy (DOE) develops standardized data templates for reporting the results of tests conducted in accordance with current DOE test procedures. Templates may be used by third-party laboratories under contract with DOE that conduct testing in support of ENERGY STAR® verification, DOE rulemakings, and enforcement of the federal energy conservation standards.

389

Performance of a Heat Pump Water Heater in the Hot-Humid Climate, Windermere, Florida (Fact Sheet), Building America Case Study: Technology Solutions for New and Existing Homes, Building Technologies Office (BTO)  

Broader source: Energy.gov (indexed) [DOE]

Performance of a Performance of a Heat Pump Water Heater in the Hot-Humid Climate Windermere, Florida Over recent years, heat pump water heaters (HPWHs) have become more read- ily available and more widely adopted in the marketplace. A key feature of an HPWH unit is that it is a hybrid system. When conditions are favorable, the unit will operate in heat pump mode (using a vapor compression system that extracts heat from the surrounding air) to efficiently provide domestic hot water (DHW). Homeowners need not adjust their behavior to conform to the heat pump's capabilities. If a heat pump cannot meet a higher water draw demand, the heater will switch to electric resistance to provide a higher heating rate. This flexibility

390

Experimental investigations on decay heat removal in advanced nuclear reactors using single heater rod test facility: Air alone in the annular gap  

SciTech Connect (OSTI)

During a loss of coolant accident in nuclear reactors, radiation heat transfer accounts for a significant amount of the total heat transfer in the fuel bundle. In case of heavy water moderator nuclear reactors, the decay heat of a fuel bundle enclosed in the pressure tube and outer concentric calandria tube can be transferred to the moderator. Radiation heat transfer plays a significant role in removal of decay heat from the fuel rods to the moderator, which is available outside the calandria tube. A single heater rod test facility is designed and fabricated as a part of preliminary investigations. The objective is to anticipate the capability of moderator to remove decay heat, from the reactor core, generated after shut down. The present paper focuses mainly on the role of moderator in removal of decay heat, for situation with air alone in the annular gap of pressure tube and calandria tube. It is seen that the naturally aspirated air is capable of removing the heat generated in the system compared to the standstill air or stagnant water situations. It is also seen that the flowing moderator is capable of removing a greater fraction of heat generated by the heater rod compared to a stagnant pool of boiling moderator. (author)

Bopche, Santosh B.; Sridharan, Arunkumar [Department of Mechanical Engineering, Indian Institute of Technology Bombay, Powai, Mumbai 400 076 (India)

2010-11-15T23:59:59.000Z

391

The minimum gas temperature at the inlet of regulators in natural gas pressure reduction stations (CGS) for energy saving in water bath heaters  

Science Journals Connector (OSTI)

Abstract In this study a computational procedure for the computation of Joule–Thomson coefficient of natural gas has been developed using fundamental thermodynamic equations and AGA-8 equation of state, and then the minimum possible temperature of the natural gas entering to the pressure regulator of city gate stations (CGS) is calculated. As a case study, a CGS located in Bistoon (of Iran's CGSs) with nominal capacity of 20,000 SCMH has been considered. A comparison has been made between the calculated results and corresponding collected data from the station within 10 months. Results of this study help to determine the minimum temperature values of entering gas with different pressures to the regulator in order to avoid hydrate formation of the outlet gas, and can be used to design appropriate temperature control systems for water bath heaters and in turn save consumed energy for gas heating. The results show that heating the gas up to calculated minimum temperatures can save energy consumption of heaters by 43%. Also, it is indicated that by applying a control system, based on the result of this study, in the CGS the payback period would be less than a year.

Esmail Ashouri; Farzad Veysi; Ehsan Shojaeizadeh; Maryam Asadi

2014-01-01T23:59:59.000Z

392

Heatpipe space power and propulsion systems  

SciTech Connect (OSTI)

Safe, reliable, low-mass space power and propulsion systems could have numerous civilian and military applications. This paper discusses two fission-powered concepts: the Heatpipe Power System (HPS) that provides power only, and the Heatpipe Bimodal System (HBS) that provides both power and thermal propulsion. Both concepts have 10 important features. First, only existing technology and recently tested fuel forms are used. Second, fuel can be removed whenever desired, greatly facilitating system fabrication and handling. Third, full electrically heated system testing is possible, with minimal operations required to replace the heaters with fuel and ready the system for launch. Fourth, the systems are passively subcritical during launch accidents. Fifth, a modular approach is used, and most technical issues can be resolved with inexpensive module tests. Sixth, bonds between dissimilar metals are minimized. Seventh, there are no single point failures during power mode operation. Eighth, fuel burnup rate is quite low to help ensure greater than 10-year system life. Ninth, there are no pumped coolant loops, and the systems can be shut down and restarted without coolant freeze/thaw concerns. Finally, a full ground nuclear test is not needed, and development costs will be low. The baseline HPS uses SNAP-10A-style thermoelectric power converters to produce 5 kWe at a system mass of about 500 kg. The unicouple thermoelectric converters have a hot shoe temperature of 1275 K and reject waste heat at 775 K. This type of thermoelectric converter has been used extensively by the space program, demonstrating an operational lifetime of decades. At higher thermal power, the same core can produce over 10 kWe using thermoelectric converters, and over 50 kWe using advanced power conversion systems.

Houts, M.G.; Poston, D.I.; Ranken, W.A.

1995-07-01T23:59:59.000Z

393

Lightning Dock Geothermal Space Heating Project: Lightning Dock...  

Open Energy Info (EERE)

and home heating systems, which consisted of pumping geothermal water and steam through passive steam heaters, and convert the systems to one using modern heat exchange units. It...

394

Measure Guideline: Condensing Boilers - Control Strategies for Optimizing Performance and Comfort in Residential Applications  

SciTech Connect (OSTI)

The combination of a gas-fired condensing boiler with baseboard convectors and an indirect water heater has become a common option for high-efficiency residential space heating in cold climates. While there are many condensing boilers available on the market with rated efficiencies in the low to mid 90% efficient range, it is imperative to understand that if the control systems are not properly configured, these heaters will perform no better than their non-condensing counterparts. Based on previous research efforts, it is apparent that these types of systems are typically not designed and installed to achieve maximum efficiency (Arena 2010). It was found that there is a significant lack of information for contractors on how to configure the control systems to optimize overall efficiency. For example, there is little advice on selecting the best settings for the boiler reset curve or how to measure and set flow rates in the system to ensure that the return temperatures are low enough to promote condensing. It has also been observed that recovery from setback can be extremely slow and, at times, not achieved. Recovery can be affected by the outdoor reset control, the differential setting on the boiler and over-sizing of the boiler itself. This guide is intended for designers and installers of hydronic heating systems interested in maximizing the overall system efficiency of condensing boilers when coupled with baseboard convectors. It is applicable to new and retrofit applications.

Arena, L.

2013-05-01T23:59:59.000Z

395

Multimedia Phase-Spaces  

Science Journals Connector (OSTI)

Dynamic phase-spaces are suggested as a way of designing and implementing interactive multimedia systems. A dynamic phase-space is a space of properties overlayed with dynamics. The space is “decorated” with multimedia resources such ... Keywords: catastrophe theory, dynamics, installation, interactive narrative, museums, phase-space

Peter Bøgh Andersen

1998-05-01T23:59:59.000Z

396

Sculpting space through sound  

E-Print Network [OSTI]

How does one experience space? What kind of information do humans collect in the process of constructing space in their mind? How does one begin to understand volume, light, texture, material, smell and sense of space? The ...

Nakagawa, Junko, 1975-

2002-01-01T23:59:59.000Z

397

In Outer Space without a Space Suit?  

E-Print Network [OSTI]

The author proposes and investigates his old idea - a living human in space without the encumbrance of a complex space suit. Only in this condition can biological humanity seriously attempt to colonize space because all planets of Solar system (except the Earth) do not have suitable atmospheres. Aside from the issue of temperature, a suitable partial pressure of oxygen is lacking. In this case the main problem is how to satiate human blood with oxygen and delete carbonic acid gas (carbon dioxide). The proposed system would enable a person to function in outer space without a space suit and, for a long time, without food. That is useful also in the Earth for sustaining working men in an otherwise deadly atmosphere laden with lethal particulates (in case of nuclear, chemical or biological war), in underground confined spaces without fresh air, under water or a top high mountains above a height that can sustain respiration.

Alexander Bolonkin

2008-06-24T23:59:59.000Z

398

In Outer Space without a Space Suit?  

E-Print Network [OSTI]

The author proposes and investigates his old idea - a living human in space without the encumbrance of a complex space suit. Only in this condition can biological humanity seriously attempt to colonize space because all planets of Solar system (except the Earth) do not have suitable atmospheres. Aside from the issue of temperature, a suitable partial pressure of oxygen is lacking. In this case the main problem is how to satiate human blood with oxygen and delete carbonic acid gas (carbon dioxide). The proposed system would enable a person to function in outer space without a space suit and, for a long time, without food. That is useful also in the Earth for sustaining working men in an otherwise deadly atmosphere laden with lethal particulates (in case of nuclear, chemical or biological war), in underground confined spaces without fresh air, under water or a top high mountains above a height that can sustain respiration.

Bolonkin, Alexander

2008-01-01T23:59:59.000Z

399

Space System Architecture  

E-Print Network [OSTI]

Final Report of SSPARC: the Space Systems, Policy, and Architecture Research Consortium (Thrust II and III)

McManus, Dr. Hugh

400

Space: Dreams of the new space race  

Science Journals Connector (OSTI)

... new-space sector has been booming, thanks to a change in its business model. Private spaceflight has always been a business for dreamers, and now one group of dreamers ... , Virginia, pioneered the marketplace for space tourism. Since 2001, it has sent five private individuals into orbit on Russian spacecraft, at US$20 million a trip. Then, ...

David Chandler

2007-08-29T23:59:59.000Z

Note: This page contains sample records for the topic "hydronic space heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Solar Concentration in Space  

Science Journals Connector (OSTI)

Solar concentrators go space. Lens and mirror-based solar concentrators have recently begun to boost photovoltaic power supplies for satellites in space. In 1998, the first mission carrying solar concentrators...

Dr. Ralf Leutz; Dr. Akio Suzuki

2001-01-01T23:59:59.000Z

402

Space-based detectors  

Science Journals Connector (OSTI)

The parallel session C5 on Space-Based Detectors gave a broad overview over the planned space missions related to gravitational wave detection. Overviews of the revolutionary science to be expected from LISA was ...

A. Sesana; W. J. Weber; C. J. Killow…

2014-11-01T23:59:59.000Z

403

Quotients of Metric Spaces  

E-Print Network [OSTI]

the properties of quotient spaces of metric spaces. We will use "iff" as an abbreviation for "if and only if". If f is a function from X onto Y, we will write f: X --->> Y....

Herman, Robert A.

1968-01-01T23:59:59.000Z

404

Architecting space communication networks  

E-Print Network [OSTI]

Reliable communication and navigation services are critical to robotic and human space missions. NASA currently provides them through three independent and uncoordinated network that consist of both Earth-based and space-based ...

Sanchez Net, Marc

2014-01-01T23:59:59.000Z

405

Space Shuttle Program Status  

E-Print Network [OSTI]

Brigham City, Utah Space Shuttle Main Engines Pratt & Whitney/Rocketdyne Canoga Park, CA NASA JSC Houston

Waliser, Duane E.

406

Cubature on Wiener space  

Science Journals Connector (OSTI)

...research-article Cubature on Wiener space Terry Lyons Nicolas Victoir...a cubature formula on Wiener space of degree m.R eferences Ben...M. 1996 CarnotCarath eodory spaces seen from within: sub-Riemannian...North-Holland Mathematical Library. Kloeden, P. E. & Platen...

2004-01-01T23:59:59.000Z

407

Whither design space?  

Science Journals Connector (OSTI)

Design space exploration is a long-standing focus in computational design research. Its three main threads are accounts of designer action, development of strategies for amplification of designer action in exploration, and discovery of computational ... Keywords: Design Space Exploration, Knowledge Representation, Search, State Space, Typed Feature Structures

Robert F. Woodbury; Andrew L. Burrow

2006-04-01T23:59:59.000Z

408

Developments in space engineering and space science  

Science Journals Connector (OSTI)

...geostationary satellite INSAT, which provides both weather observation and...of results in satellite missions monitoring space weather as for those...At that time satellite data were only...on numerical weather predictions...

2003-01-01T23:59:59.000Z

409

Modeling the thermal-hydrologic processes in a large-scale underground heater test in partially saturated fractured tuff  

SciTech Connect (OSTI)

The Drift Scale Test (DST) is being conducted in an underground facility at Yucca Mountain, Nevada, to probe the coupled thermal, hydrological, mechanical, and chemical processes likely to occur in the fractured rock mass around a potential high-level nuclear waste repository. Thermal-hydrological processes in the DST have been simulated using a three-dimensional numerical model. The model incorporates the realistic test configuration and all available site-specific measurements pertaining to the thermal and hydrological properties of the unsaturated fractured tuff of the test block. The modeled predictions were compared to the extensive set of measured data collected in the first year of this 8-year-long test. The mean error between the predictions and measurement at 12 months of heating for over 1600 temperature sensors is about 2 degrees C. Heat-pipe signature in the temperature data, indicating two-phase regions of liquid-vapor counterflow, is seen in both the measurements and simulated results. The redistribution of moisture content in the rock mass (resulting from vaporization and condensation) was probed by periodic air-injection testing and geophysical measurements. Good agreement also occurred between the model predictions and these measurements. The general agreement between predictions from the numerical simulations and the measurements of the thermal test indicates that our fundamental understanding of the coupled thermal-hydrologic processes at Yucca Mountain is sound. However, effects of spatial heterogeneity from discrete fractures that are observed in the temperature data are not matched by simulations from the numerical model, which treat the densely spaced fractures as a continuum.

Birkholzer, J.T.; Tsang, Y.W.

1999-06-24T23:59:59.000Z

410

TANK SPACE OPTIONS REPORT  

SciTech Connect (OSTI)

Since this report was originally issued in 2001, several options proposed for increasing double-shell tank (DST) storage space were implemented or are in the process of implementation. Changes to the single-shell tank (SST) waste retrieval schedule, completion of DST space saving options, and the DST space saving options in progress have delayed the projected shortfall of DST storage space from the 2007-2011 to the 2018-2025 timeframe (ORP-11242, River Protection Project System Plan). This report reevaluates options from Rev. 0 and includes evaluations of new options for alleviating projected restrictions on SST waste retrieval beginning in 2018 because of the lack of DST storage space.

WILLIS WL; AHRENDT MR

2009-08-11T23:59:59.000Z

411

Space Systems Finland 1 Deployment in the Space Sector  

E-Print Network [OSTI]

© Space Systems Finland 1 Deployment in the Space Sector #12;© Space Systems Finland 2 SW Constraints Design Requirements User Requirements SW Requirements #12;© Space Systems Finland 3 The space, but there is no viable alternative · Many requirements are not testable #12;© Space Systems Finland 4 SSF OBJECTIVES

Southampton, University of

412

Berkeley Lab Space  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Space Space Committee Charter Articles Presentations Feedback Contact Us ANNOUNCEMENTS Space Planning Advisory Committee (SPAC) The LBNL Space Planning Advisory Committee (SPAC) was chartered in January 2010 to help manage the growth, both in the short term as well as long term. Specifically, SPAC will recommend to senior laboratory management policies and procedures for the allocation and utilization of space and opportunities for increased efficiency. (For the complete charter, click here.)We welcome comments and suggestions. Our email is: SPAC@lbl.gov. SPAC (Space Planning Advisory Committee) SPAC Members Telephone Number Email Rich Diamond 510-486-4459 RCDiamond@lbl.gov Rich McClure 510-486-4486 RMMcClure@lbl.gov Diana Attia 510-486-7399 DMAttia@lbl.gov Rebecca Rishell 510-486-6689

413

AB Space Engine  

E-Print Network [OSTI]

On 4 January 2007 the author published the article Wireless Transfer of Electricity in Outer Space in http://arxiv.org wherein he offered and researched a new revolutionary method of transferring electric energy in space. In that same article, he offered a new engine which produces a large thrust without throwing away large amounts of reaction mass (unlike the conventional rocket engine). In the current article, the author develops the theory of this kind of impulse engine and computes a sample project which shows the big possibilities opened by this new AB-Space Engine. The AB-Space Engine gets the energy from ground-mounted power; a planet electric station can transfer electricity up to 1000 millions (and more) of kilometers by plasma wires. Author shows that AB-Space Engine can produce thrust of 10 tons (and more). That can accelerate a space ship to some thousands of kilometers/second. AB-Space Engine has a staggering specific impulse owing to the very small mass expended. The AB-Space Engine reacts not by expulsion of its own mass (unlike rocket engine) but against the mass of its planet of origin (located perhaps a thousand of millions of kilometers away) through the magnetic field of its plasma cable. For creating this plasma cable the AB-Space Engine spends only some kg of hydrogen.

Alexander Bolonkin

2008-03-02T23:59:59.000Z

414

Passive solar space heating  

SciTech Connect (OSTI)

An overview of passive solar space heating is presented indicating trends in design, new developments, performance measures, analytical design aids, and monitored building results.

Balcomb, J.D.

1980-01-01T23:59:59.000Z

415

Total Space Heat-  

Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

Buildings Energy Consumption Survey: Energy End-Use Consumption Tables Total Space Heat- ing Cool- ing Venti- lation Water Heat- ing Light- ing Cook- ing Refrig- eration...

416

Neutron Tomography and Space  

E-Print Network [OSTI]

Kevin Shields, “Optimization of neutron tomography for rapidNEUTRON TOMOGRAPHY AND SPACE Hal Egbert, Ronald Walker, R.industrial applications[1]. Neutron Computed Tomography was

Egbert, Hal; Walker, Ronald; Flocchini, R.

2007-01-01T23:59:59.000Z

417

Buildings Energy Data Book  

Buildings Energy Data Book [EERE]

5.1 Building Materials/Insulation 5.1 Building Materials/Insulation 5.2 Windows 5.3 Heating, Cooling, and Ventilation Equipment 5.4 Water Heaters 5.5 Thermal Distribution Systems 5.6 Lighting 5.7 Appliances 5.8 Active Solar Systems 5.9 On-Site Power 6Energy Supply 7Laws, Energy Codes, and Standards 8Water 9Market Transformation Glossary Acronyms and Initialisms Technology Descriptions Building Descriptions Other Data Books Biomass Energy Transportation Energy Power Technologies Hydrogen Download the Entire Book Skip down to the tables Chapter 5 contains market and technology data on building materials and equipment. Sections 5.1 and 5.2 cover the building envelope, including building assemblies, insulation, windows, and roofing. Sections 5.3 through 5.7 cover equipment used in buildings, including space heating, water heating, space cooling, lighting, thermal distribution (ventilation and hydronics), and appliances. Sections 5.8 and 5.9 focus on energy production from on-site power equipment. The main points from this chapter are summarized below:

418

Today's Space Weather Space Weather Case Studies  

E-Print Network [OSTI]

tank on Space ShuQle trips alarms Impacts #12;Quebec electrical blackout: "GIC" (ground-induced current) Quebec sits on are large sheet of bedrock [rock shield], and grounding is difficult Hydro-Quebec's power grid is, within 90-sec of storm onset

419

National Aeronautics and Space Administration International Space  

E-Print Network [OSTI]

sustainability and ensure their early incorporation in the architecture ­ Apply a phased approach to exploration Partnerships Strategy · NASA leadership of a sustainable and affordable human space exploration of many costs (not LCC) or obtain funding or resource offsets 2. Enhance sustainability thru interdependent

Waliser, Duane E.

420

Space Plasma Physics  

Science Journals Connector (OSTI)

...W.D., BEAM-PLASMA DISCHARGE - BUILDUP...DURING ELECTRON BEAM-PLASMA INTERACTIONS, GEOPHYSICAL...ELECTRON-BEAM IN THE ATMOSPHERE, PLANETARY AND SPACE...1980 ). Space plasma physics: electron...regula' occurred at large pitch angles. Note...in quite different areas. (i) There is...

KLAUS WILHELM; WOLFGANG STÜDEMANN; WILLIBALD RIEDLER

1984-07-13T23:59:59.000Z

Note: This page contains sample records for the topic "hydronic space heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

SPACE RESOURCES ROUNDTABLE IX  

E-Print Network [OSTI]

in developing the resources of space, including the Moon, Mars, asteroids, comets, and other bodies organizations. The ninth Space Resources Roundtable solicits presentations about: · Orbital or landed measurements of the Moon, Mars, and/or asteroids and comets to identify and characterize potential resources

Rathbun, Julie A.

422

Towards interactive smart spaces  

Science Journals Connector (OSTI)

Recently, we have been witnessing how various social applications and networking services are being integrated more deeply into our daily lives. Until now, social interaction has been attributed exclusively to humans, while resources and the smart space ... Keywords: Context-Awareness, Knowledge-Based Systems, Smart Spaces, Social Interaction

Ekaterina Gilman; Oleg Davidyuk; Xiang Su; Jukka Riekki

2013-01-01T23:59:59.000Z

423

AB Space Engine  

E-Print Network [OSTI]

On 4 January 2007 the author published the article Wireless Transfer of Electricity in Outer Space in http://arxiv.org wherein he offered and researched a new revolutionary method of transferring electric energy in space. In that same article, he offered a new engine which produces a large thrust without throwing away large amounts of reaction mass (unlike the conventional rocket engine). In the current article, the author develops the theory of this kind of impulse engine and computes a sample project which shows the big possibilities opened by this new AB-Space Engine. The AB-Space Engine gets the energy from ground-mounted power; a planet electric station can transfer electricity up to 1000 millions (and more) of kilometers by plasma wires. Author shows that AB-Space Engine can produce thrust of 10 tons (and more). That can accelerate a space ship to some thousands of kilometers/second. AB-Space Engine has a staggering specific impulse owing to the very small mass expended. The AB-Space Engine reacts not b...

Bolonkin, Alexander

2008-01-01T23:59:59.000Z

424

SPACE TECHNOLOGY Actual Estimate  

E-Print Network [OSTI]

SPACE TECHNOLOGY TECH-1 Actual Estimate Budget Authority (in $ millions) FY 2011 FY 2012 FY 2013 FY.7 247.0 Exploration Technology Development 144.6 189.9 202.0 215.5 215.7 214.5 216.5 Notional SPACE TECHNOLOGY OVERVIEW .............................. TECH- 2 SBIR AND STTR

425

On globally Symmetric Finsler spaces  

E-Print Network [OSTI]

The paper consider the symmetric of Finsler spaces. We give some conditions about globally symmetric Finsler spaces. Then we prove that these spaces can be written as a coset space of Lie group with an invariant Finsler metric. Finally, we prove that such a space must be Berwaldian

Khatamy, R Chavosh

2011-01-01T23:59:59.000Z

426

Simplified Space Conditioning  

Broader source: Energy.gov (indexed) [DOE]

Simplified Space Conditioning Simplified Space Conditioning Duncan Prahl, RA IBACOS, Inc. Building America Technical Update April 29, 2013 Simplified Space Conditioning Rethinking HVAC Design * Traditional Method - Assume envelope losses dictate the load - Room by room load analysis - Pick Equipment and distribute to meet the load in each room * New Method - Consider how the occupants live in the building - Seriously consider internal gains in both heating and cooling - Consider ventilation strategy - Design system Simplified Space Conditioning If you are: * A production builder * Participating in "above code" programs * Following ACCA Manual RS or ASHRAE 55 * Need to prove "delivering heat to each habitable room" * Concerned about litigation * Play it safe, Use Manual J, S & D and condition every

427

Live From Outer Space  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Live from Outer Space: How Cells Influence the Growth of Nanostructures Live from Outer Space: How Cells Influence the Growth of Nanostructures Far above the heads of Earthlings, arrays of single-cell creatures embedded in nanostructures ride on the International Space Station (courtesy of Sandia National Laboratories and the University of New Mexico, NASA, and the U.S. Air Force) to test whether nanostructures whose formations were directed by yeast and other single cells can create more secure homes for their occupants-even in the vacuum and radiation of outer space-than those created by more standard chemical procedures. Cheap, tiny, and very lightweight sensors of chemical or biological agents could be made from long-lived cells that require no upkeep, yet sense and then communicate effectively with each other and their external

428

Astrophysics and Space Instrumentation  

Science Journals Connector (OSTI)

Instrumentation for particle and high-energy photon measurements in space must provide high levels of performance while meeting the severe constraints imposed by flight. Direct measurements are required spanni...

John W. Mitchell; Thomas Hams; Thomas Hams

2012-01-01T23:59:59.000Z

429

Space Flight Requirements  

E-Print Network [OSTI]

Science Glovebox), SpaceDrums (Levitator), EMCS (European Modular Cultivation System), PCDF (Protein MERLIN, HDPCG, PCF, CVDA, VDA2, DCPCG, PCFVG, PCFLST, CRIMM CRIMM Commercial Refrigerator Incubator Growth GLACIER General Laboratory Active Cryogenic ISS Experiment Refrigerator HDPCG High Density

430

Notes on sexuality & space  

E-Print Network [OSTI]

Very little has been written on sexuality in architectural scholarship. Sexuality & Space (Princeton Architectural Press, 1992) contains the proceedings of an eponymous 1990 conference at Princeton University, and was both ...

Jacobson, Samuel Ray

2013-01-01T23:59:59.000Z

431

Lid heater for glass melter  

DOE Patents [OSTI]

A glass melter having a lid electrode for heating the glass melt radiantly. The electrode comprises a series of INCONEL 690 tubes running above the melt across the melter interior and through the melter walls and having nickel cores inside the tubes beginning where the tubes leave the melter interior and nickel connectors to connect the tubes electrically in series. An applied voltage causes the tubes to generate heat of electrical resistance for melting frit injected onto the melt. The cores limit heat generated as the current passes through the walls of the melter. Nickel bus connection to the electrical power supply minimizes heat transfer away from the melter that would occur if standard copper or water-cooled copper connections were used between the supply and the INCONEL 690 heating tubes.

Phillips, Terrance D. (617 Chestnut Ct., Aiken, SC 29803)

1993-01-01T23:59:59.000Z

432

Electric and Gasoline Vehicle Lifecycle Cost and Energy-Use Model  

E-Print Network [OSTI]

= the efficiency of the propane space heater (BTU-delivered/the efficiency of the heater, and the cost of propane. The

Delucchi, Mark; Burke, Andy; Lipman, Timothy; Miller, Marshall

2000-01-01T23:59:59.000Z

433

Efficiency Ratings for the Daiken AC (Americas), Inc.  

E-Print Network [OSTI]

Efficiency Ratings for the Daiken AC (Americas), Inc. Altherma Air-to-Water Source Heat Pump System Description Model No. Capacity (tons) Space Heating Space Cooling SEER Water Heating Efficiency (E.F.)1 CEC Listing Date Heating Combined Hydronic HSPF E.F. Split Altherma LT ERLQ036

434

Earth, Space Sciences  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Earth, Space Sciences Earth, Space Sciences /science-innovation/_assets/images/icon-science.jpg Earth, Space Sciences National security depends on science and technology. The United States relies on Los Alamos National Laboratory for the best of both. No place on Earth pursues a broader array of world-class scientific endeavors. Climate, Ocean and Sea Ice Modeling (COSIM)» Earth A team of scientists is working to understand how local changes in hydrology might bring about major changes to the Arctic landscape, including the possibility of a large-scale carbon release from thawing permafrost. Bryan Travis, an expert in fluid dynamics, is author of the Mars global hydrology numerical computer model, or MAGHNUM, used for calculating heat and fluid transport phenomena. (MAGHNUM was previously

435

Fun in Space  

Science Journals Connector (OSTI)

This after-dinner address attempts to point up in a simplified way the amusing as well as some of the more serious problems which arise in connection with flight into space. Figures are given to challenge some of the more fanciful claims about the value of the moon as a military base noting the very large amounts of fuel required to take weapons up to the moon and then to return them to the earth. Some of the important research problems in physics and astronomy which can be carried out by the use of space vehicles are enumerated. As examples of a space science enterprise the results of the magnetic field measurements by the Pioneer V package are summarized. The impractibility of using the moon and other planets as colonies for the earth's excess population is also demonstrated.

Lee A. DuBridge

1960-01-01T23:59:59.000Z

436

Nonlinear classification of Banach spaces  

E-Print Network [OSTI]

Hilbert space when p> 2. We then build upon the method of this proof to show that a quasi-Banach space coarsely embeds into a Hilbert space if and only if it is isomorphic to a subspace of L0(??) for some probability space (?,B,??)....

Randrianarivony, Nirina Lovasoa

2005-11-01T23:59:59.000Z

437

Photovoltaic module start-up for the International Space Station  

SciTech Connect (OSTI)

The International Space Station (ISS) US On-Orbit Segment Electric Power System (EPS) uses four photovoltaic modules (PVMs). Each PVM consists of solar array wings (SAW) for converting solar flux to electric power, nickel-hydrogen batteries for electric energy storage, electronic boxes for electric voltage control and power switching, and a thermal control system (TCS) for maintaining selected PVM components within their normal operating temperature ranges. Each PVM consists of two independent power channels, which are started sequentially. The start-up consists of deploying the SAW and photovoltaic radiator (PVR), initialization and check out of all hardware, thermally conditioning batteries, and charging batteries. After start-up, each PVM power channel is able to generate, store, and distribute electric power to ISS loads. Electric power to support start-up of the first PVM is provided by the NSTS via two auxiliary power converter units (APCUs), one per channel. During sunlit periods, the SAW provides power for the battery heaters (for thermal conditioning, as needed) and battery charging. During eclipse periods, the APCU maintains the channel in a standby mode. After start-up is complete, the APCU is disconnected and the PVM operates independently. The process used to start-up the first PVM on the ISS is described in this paper. Procedures used to bring dormant batteries to their normal operating temperature range and then to charge them to 100% state of charge (SOC) are also described. Total time required to complete start-up and the APCU power required during start-up are computed and compared to the requirements.

Hajela, G.P.; Hague, L.M. [Rockwell International, Canoga Park, CA (United States). Rocketdyne Div.

1996-12-31T23:59:59.000Z

438

2011 Confined Space Program Update  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Confined Space Entry Program Update Confined Space Entry Program Update IMPORTANT: After reading this document, click the "Get Course Credit" link at the bottom of the page. You will then log in to the EHS training system using your LDAP to get course credit. LBNL's confined space entry program was substantially improved this year. Several new features have been included which improve overall safety for Confined Space Entrants and better align the confined space entry program with the OSHA requirements. As an Activity Lead, Confined Space Entrant or Entry Supervisor, you should be aware of the following: We improved the procedures for safely working in confined spaces. Please review the new Chapter 34 in Publication 3000. Additionally, we have a new planning tool known as the confined space inventory which is a registry of LBNL's confined spaces, their potential hazards and safe work procedures unique to a particular confined space.

439

Space science and policy  

Science Journals Connector (OSTI)

......research-article Features Space science and policy David Southwood David Southwood is a Senior...Moreover, the ESA industrial return policy produced its own problems, as I'll...science in Europe. The industrial return policy is at the heart of ESA and builds in a......

David Southwood

2014-12-01T23:59:59.000Z

440

Hacking Spaces: Place as Interface  

Science Journals Connector (OSTI)

In this article, we analyze the complex rationales—both transparent to us and, at times, made visible—underneath the instructional spaces in which we work and teach. To do so, we first situate space analysis in the larger, national conversations about instructional spaces and then through the work of computers and writing scholars. We conclude with an analysis of instructional spaces at our institution. These are spaces specific to our locale, but spaces we think are quite common at most institutions of higher education. Perhaps more importantly, we situate this space analysis on issues these spaces pose—issues of restricted movement, impaired ability to collaborate, sensory disruption, limited leadership ability, and functional/material constraints. We attempt to return to the roots of hacking and to situate hacking as a particular tool for negotiating and, at times, disrupting the assumptions built under, within, and across instructional spaces.

Douglas M. Walls; Scott Schopieray; Dànielle Nicole DeVoss

2009-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hydronic space heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Propagators in Lagrangian space  

SciTech Connect (OSTI)

It has been found recently that propagators, e.g. the cross correlation spectra of the cosmic fields with the initial density field, decay exponentially at large k in an Eulerian description of the dynamics. We explore here similar quantities defined for a Lagrangian space description. We find that propagators in Lagrangian space do not exhibit the same properties: they are found not to be monotonic functions of time, and to track back the linear growth rate at late time (but with a renormalized amplitude). These results have been obtained with a novel method which we describe alongside. It allows the formal resummation of the same set of diagrams as those that led to the known results in Eulerian space. We provide a tentative explanation for the marked differences seen between the Eulerian and the Lagrangian cases, and we point out the role played by the vorticity degrees of freedom that are specific to the Lagrangian formalism. This provides us with new insights into the late-time behavior of the propagators.

Bernardeau, Francis; Valageas, Patrick [Institut de Physique Theorique, CEA/DSM/IPhT, Unite de recherche associee au CNRS, CEA/Saclay, 91191 Gif-sur-Yvette cedex, France and Canadian Institute for Theoretical Astrophysics, University of Toronto, 60 St. George Street, Toronto, Ontario M5S 3H8 (Canada); Service de Physique Theorique, CEA/DSM/SPhT, Unite de recherche associee au CNRS, CEA/Saclay, 91191 Gif-sur-Yvette cedex (France)

2008-10-15T23:59:59.000Z

442

National Aeronautics and Space Administration Space Launch System  

E-Print Network [OSTI]

was previously designated the space shuttle main engine and is built by Aerojet Rocketdyne of Sacramento, Calif

Waliser, Duane E.

443

National Aeronautics and Space Administration International Space Station  

E-Print Network [OSTI]

and technological endeavor ever undertaken, involving support from five space agencies representing 16 nations. Once's solar panels exceed the wingspan of a Boeing 777 jetliner and harness enough energy from the sunNational Aeronautics and Space Administration NASAfacts International Space Station Clearly

444

Building America Case Study: Evaluation of Residential Integrated Space/Water Heat Systems, Illinois and New York (Fact Sheet)  

SciTech Connect (OSTI)

This multi-unit field demonstration of combined space and water heating (combi) systems was conducted to help document combi system installation and performance issues that needed to be addressed through research. The objective of the project was to put commercialized forced-air tankless combi units into the field through local contractors that were trained by manufacturers and GTI staff under the auspices of utility-implemented Emerging Technology Programs. With support from PARR, NYSERDA and other partners, the project documented system performance and installations in Chicago and New York. Combi systems were found to save nearly 200 therms in cold climates at efficiencies between about 80% and 94%. Combi systems using third-party air handler units specially designed for condensing combi system operation performed better than the packaged integrated combi systems available for the project. Moreover, combi systems tended to perform poorly when the tankless water heaters operating at high turn-down ratios. Field tests for this study exposed installation deficiencies due to contractor unfamiliarity with the products and the complexity of field engineering and system tweaking to achieve high efficiencies. Widespread contractor education must be a key component to market expansion of combi systems. Installed costs for combi systems need to come down about 5% to 10% to satisfy total resource calculations for utility-administered energy efficiency programs. Greater sales volumes and contractor familiarity can drive costs down. More research is needed to determine how well heating systems such as traditional furnace/water heater, combis, and heat pumps compare in similar as-installed scenarios, but under controlled conditions.

Not Available

2014-11-01T23:59:59.000Z

445

The science of space weather  

Science Journals Connector (OSTI)

...magnetic reconnection|space weather| 1. Introduction Fifty...31 January 1958, the satellite Explorer 1 was launched...et al. 2005). (e) Satellite anomalies Space weather can cause a variety of satellite anomalies such as surface...

2008-01-01T23:59:59.000Z

446

Space Contamination and Ecological Problems  

Science Journals Connector (OSTI)

The state-of-the-art theories concerning the problem of pollution by space vehicles are discussed and a variety of mechanical problems’ formulations are considered, as applied to environmental problems in space.

V. M. Fomin; A. M. Kharitonov…

1995-01-01T23:59:59.000Z

447

Europeanizing Territoriality - Towards Soft Spaces?  

E-Print Network [OSTI]

spatial or development planning might provide a way forward. A number of studies across Europe have highlighted and explored the emergence of so called soft spaces as attempts to create hybrids of territorial and relational spaces (see, for example... by creating bespoke spaces for dealing with specific issues such as regeneration, integrating different sectors such as transport, infrastructure, education, etc. in such processes operating at variable scales. Studies of soft spaces have focused upon...

Allmendinger, Phil; Chilla, Tobias; Sielker, Franziska

2014-01-01T23:59:59.000Z

448

Demystifying White Spaces Xuemin Hongl  

E-Print Network [OSTI]

Demystifying White Spaces Xuemin Hongl , Cheng-Xiang Wangl , John Thompson2 , and Yan Zhang3 1Joint.wang@hw.ac.uk.john.thompson@ed.ac.uk. yanzhang@ieee.org Abstract-White spaces refer to the unused frequency voids across time or space. The vast existence of white spaces has been validated by many measurements and is widely regarded as an undesirable

Wang, Cheng-Xiang

449

2012 RAL Space Sarah James  

E-Print Network [OSTI]

are here Chilton Ionosonde #12;© 2012 RAL Space #12;What is the ionosphere? Marconi's transatlantic radio

450

Space, Health and Population Economics  

E-Print Network [OSTI]

Space, Health SHaPE and Population Economics Changing Demographics and Immigration: Implications for IndianaImplications for Indiana Brigitte Waldorf, Purdue University Farm Policy Study Group b 20 07 December 2010 #12;Space, Health SHaPE and Population Economics America is ... ... Aging #12;Space, Health

451

Geodesic spaces : momentum Groups : symmetry  

E-Print Network [OSTI]

Geodesic spaces : momentum :: Groups : symmetry Vaughan Pratt Stanford University BLAST 2010 a · b denoting b rotated 90 degrees about a. End of reprise. 3. This talk; Geodesic spaces At FMCS. as points evenly spaced along a geodesic , right distributivity expresses a symmetry of about an arbitrary

Pratt, Vaughan

452

National Aeronautics and Space Administration  

E-Print Network [OSTI]

really mark the end of outer space as a field for humankind's visions, longings, and projections ccononttiinnuueedd onon nenexxtt ppaagege Berlin Symposium on Outer Space and the End of Utopia in the 1970s By Friederike Mehl, Universiteit van Amsterdam, FriederikeMehl@gmx.de Did the end of the Space Age in the 1970s

453

Policies on Japan's Space Industry  

E-Print Network [OSTI]

as a strategic industry Practical space use in National Security Diplomacy ...etc Policy Administrative Structure on the Basic Space Law legislated in 2008. 1. The government sets space policy as a national strategy utilization environment Develop new markets with small size satellites and rockets Promote the serialization

454

National Aeronautics and Space Administration  

E-Print Network [OSTI]

National Aeronautics and Space Administration Launch Services Program Earth's Bridge to Space 2012 roles, getting rockets and satellites ready for flight, on their way, and all the way to orbit absolutely instrumental for the United States to have access to a dependable and secure Earth-to-space bridge

455

Upgrading Below Grade Spaces  

Broader source: Energy.gov (indexed) [DOE]

Patrick H. Huelman, Sam Breidenbach, Steve Schirber Patrick H. Huelman, Sam Breidenbach, Steve Schirber NorthernSTAR Building America Partnership Upgrading Below Grade Spaces Residential Energy Efficiency Stakeholder March 1, 2012 Austin, TX * Act 1: Technical Challenges & Opportunities - Pat Huelman, University of Minnesota * Act 2: Assessing Homeowner Priorities & Risks - Sam Breidenbach, TDS Custom Construction * Act 3: An Industry Perspective - Steve Schirber, Cocoon Act 1. Upgrade Below Grade * Basement Remodeling: It Doesn't Get Any Riskier! - Combustion safety - Foundation moisture - Radon (& other soil gases) - Biologicals (mold, dust mites, etc.) - Garage gases (if attached) * And front and center are uncontrolled... - negative pressures in basements (beyond stack)

456

space booklet_DOE  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

U U C L E A R E N E R G Y DOE/NE-0071 U . S . D e p a r t m e n t o f E n e r g y O f f i c e o f N u c l e a r E n e r g y , S c i e n c e a n d T e c h n o l o g y N UCLEAR Power in Space 2

457

Hyper Space Issue 2  

E-Print Network [OSTI]

University, Indianapolis, Indiana. Ed.: How real is STAR WARS? Nick: I enjoyed seeing the movie, it was funl I found the story reasonable. The models and special effects were terrificI There were a couple of errors such as the misuaaof the concept... space without any sound may be uninteresting to the audience. Ed.: What about faster than light travel? Nick: Hyper drive is impossible if you use conventional physics starting from a finite position. But if you start in a different place hyperdrive...

1977-01-01T23:59:59.000Z

458

SPACE BASED INTERCEPTOR SCALING  

SciTech Connect (OSTI)

Space Based Interceptor (SBI) have ranges that are adequate to address rogue ICBMs. They are not overly sensitive to 30-60 s delay times. Current technologies would support boost phase intercept with about 150 interceptors. Higher acceleration and velocity could reduce than number by about a factor of 3 at the cost of heavier and more expensive Kinetic Kill Vehicles (KKVs). 6g SBI would reduce optimal constellation costs by about 35%; 8g SBI would reduce them another 20%. Interceptor ranges fall rapidly with theater missile range. Constellations increase significantly for ranges under 3,000 km, even with advanced interceptor technology. For distributed launches, these estimates recover earlier strategic scalings, which demonstrate the improved absentee ratio for larger or multiple launch areas. Constellations increase with the number of missiles and the number of interceptors launched at each. The economic estimates above suggest that two SBI per missile with a modest midcourse underlay is appropriate. The SBI KKV technology would appear to be common for space- and surface-based boost phase systems, and could have synergisms with improved midcourse intercept and discrimination systems. While advanced technology could be helpful in reducing costs, particularly for short range theater missiles, current technology appears adequate for pressing rogue ICBM, accidental, and unauthorized launches.

G. CANAVAN

2001-02-01T23:59:59.000Z

459

Magnetic reconnection in space  

SciTech Connect (OSTI)

Models of magnetic reconnection in space plasmas generally consider only a segment of the magnetic field lines. The consideration of only a segment of the lines is shown to lead to paradoxical results in which reconnection can be impossible even in a magnetic field constrained to be curl free or can be at an Alfven rate even when the plasma is a perfect conductor. A model of reconnecting magnetic fields is developed which shows the smallness of the interdiffusion distance {delta}{sub d} of magnetic field lines does not limit the speed of reconnection but does provide a reconnection trigger. When the reconnection region has a natural length L{sub r}, the spatial scale of the gradient of magnetic field across the magnetic field lines must reach L{sub g} Almost-Equal-To 0.3L{sub r}/ln(L{sub r}/{delta}{sub d}) for fast reconnection to be triggered, which implies a current density j Almost-Equal-To B/{mu}{sub 0}L{sub g} that is far lower than that usually thought required for fast reconnection. The relation between magnetic reconnection in space and in toroidal laboratory plasmas is also discussed.

Boozer, Allen H. [Department of Applied Physics and Applied Mathematics, Columbia University, New York, New York 10027 (United States)

2012-09-15T23:59:59.000Z

460

Life of Montana Insurance Company solar system: operation and maintenance manual  

SciTech Connect (OSTI)

The solar space heating system for the three-story home office building of the Life of Montana Insurance Company in Bozeman, Montana, is described. The system utilizes 3885 net sq. ft. of Sunworks hydronic collectors and two 3000 gal. heat storage tanks. Engineering drawings of the system are included, and an operation and maintenance manual is included. (WHK)

Not Available

1980-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "hydronic space heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Texas Gas Service - Residential Energy Efficiency Rebate Program |  

Broader source: Energy.gov (indexed) [DOE]

Texas Gas Service - Residential Energy Efficiency Rebate Program Texas Gas Service - Residential Energy Efficiency Rebate Program Texas Gas Service - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Sealing Your Home Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Ventilation Heating Heat Pumps Water Heating Windows, Doors, & Skylights Program Info State Texas Program Type Utility Rebate Program Rebate Amount Attic Insulation: Up to $300 Duct Sealing: $0.08/sq ft. Natural Gas Equipment for Weatherization: Free Residential Hydronic Heating Program: $125 Water Heater: $40 Tankless or Super High-efficiency Water Heater: $300 Solar Water Heater with Natural Gas Backup: $750 Furnace $75 Furnace Tune-Up: $40

462

AERaSPACE CORPORATION  

Office of Legacy Management (LM)

THE ' THE ' AERaSPACE CORPORATION Suite 300, 955 L' &njon~ Pkzza. S. W., Washingvan. D.C. 200242174, Tekphanc (202) 488~6CllO 7117-03.87.cdy.43 23 September 1987 CA CA.Ot M r. Andrew Wallo, III. NE-23 Division of Facility & Site cr.05 Decommissioning Projects FL .0-d U.S. Department of Energy TAl.OL Germantown; Maryland 20545 JA/.OZ 1hJ . o-01 Dear M r. Wallo: flA.05 ELIMINATION RECOMMENDATION -- COLLEGES AND UNIVERSITIES M /4.0-* 11 D.OF The attached elimination recommendation was prepared in accordance ML.o= with your suggestion during our meeting on 22 September. The recommendation nO.o-02 includes 26 colleges and universities identified,in Enclosure 4 to Aerospace letter subject: Status of Actions - FUSRAP Site List, dated MO.03. 27 May 1987; three institutions (Tufts College, University of Virginia,

463

Machian space quanta  

E-Print Network [OSTI]

A new model for space and matter is obtained by joining every pair of point charges in the observable universe by an ethereal string. Positive gravitational potential energy in each string gives an attractive gravitational force due to the action of an energy conservation constraint. Newton's laws of motion are derived and inertia is explained in accordance with Mach's principle. The Machian string model gives a surprisingly simple way to understand the expansion history of the Universe. The decelerating expansion in the radiation era and the matter era is explained without using General Relativity and the transition from deceleration to acceleration is explained without the need to introduce a separate 'dark energy' component. The interaction between Machian strings gives a physical model for modified Newtonian dynamics (MOND) and is therefore an alternative to 'dark matter'.

Essex, David W

2015-01-01T23:59:59.000Z

464

Machian space quanta  

E-Print Network [OSTI]

A new model for space and matter is obtained by joining every pair of point charges in the observable universe by an ethereal string. Positive gravitational potential energy in each string gives an attractive gravitational force due to the action of an energy conservation constraint. Newton's laws of motion are derived and inertia is explained in accordance with Mach's principle. The Machian string model gives a surprisingly simple way to understand the expansion history of the Universe. The decelerating expansion in the radiation era and the matter era is explained without using General Relativity and the transition from deceleration to acceleration is explained without the need to introduce a separate 'dark energy' component. The interaction between Machian strings gives a physical model for modified Newtonian dynamics (MOND) and is therefore an alternative to 'dark matter'.

David W. Essex

2015-01-25T23:59:59.000Z

465

General-purpose heat source project and space nuclear safety and fuels program. Progress report  

SciTech Connect (OSTI)

Studies related to the use of /sup 238/PuO/sub 2/ in radioisotopic power systems carried out for the Advanced Nuclear Systems and Projects Division of LASL are presented. The three programs involved are: general-purpose heat source development; space nuclear safety; and fuels program. Three impact tests were conducted to evaluate the effects of a high temperature reentry pulse and the use of CBCF on impact performance. Additionally, two /sup 238/PuO/sub 2/ pellets were encapsulated in Ir-0.3% W for impact testing. Results of the clad development test and vent testing are noted. Results of the environmental tests are summarized. Progress on the Stirling isotope power systems test and the status of the improved MHW tests are indicated. The examination of the impact failure of the iridium shell of MHFT-65 at a fuel pass-through continued. A test plan was written for vibration testing of the assembled light-weight radioisotopic heater unit. Progress on fuel processing is reported.

Maraman, W.J.

1980-02-01T23:59:59.000Z

466

Passive Solar Space Heat | Open Energy Information  

Open Energy Info (EERE)

Passive Solar Space Heat Incentives Retrieved from "http:en.openei.orgwindex.php?titlePassiveSolarSpaceHeat&oldid26718...

467

Radioisotopes: Energy for Space Exploration  

SciTech Connect (OSTI)

Through a strong partnership between the Energy Department's office of Nuclear Energy and NASA, Radioisotope Power Systems have been providing the energy for deep space exploration.

Carpenter, Bob; Green, James; Bechtel, Ryan

2011-01-01T23:59:59.000Z

468

Radioisotopes: Energy for Space Exploration  

ScienceCinema (OSTI)

Through a strong partnership between the Energy Department's office of Nuclear Energy and NASA, Radioisotope Power Systems have been providing the energy for deep space exploration.

Carpenter, Bob; Green, James; Bechtel, Ryan

2013-05-29T23:59:59.000Z

469

Portfolio Manager Space Type Discussion  

Broader source: Energy.gov [DOE]

This presentation, given through the DOE's Technical Assitance Program (TAP), provides a discussion about space/type in regards to the Portfolio Manager Initiative.

470

Development of a coal fired pulse combustor for residential space heating. Technical progress report, July--September 1987  

SciTech Connect (OSTI)

The systematic development of the residential combustion system is divided into three phases. Only Phase I is detailed here. Phase I constitutes the design, fabrication, testing, and evaluation of a pulse combustor sized for residential space heating. Phase II is an optional phase to develop an integrated system including a heat exchanger. Phase III is projected as a field test of the integrated coal-fired residential space heater. The Phase I effort was nearing completion during this reporting period and a final report is in preparation. The configuration testing was completed early in the period and based upon results of the configuration tests, an optimized configuration for the experimental development testing was chosen. The refractory-lined chambers were fabricated and tested from mid-September through early October. The tandem unit was operated on dry micromized coal without support gas or excitation air for periods lasting from one to three hours. Performance was stable and turndown ratios of 3:1 were achieved during the first three-hour test. A early commercial residential heating system configuration has been identified on the basis of the development testing conducted throughout the first phase of this effort. The development effort indicates that the residential unit goals are achievable with some additional product improvement effort to increase carbon burn-out efficiency, reduce CO emissions and develop a reliable and compact dry, ultrafine coal feed system (not included in the present effort).

NONE

1987-12-31T23:59:59.000Z

471

Physics in discrete spaces (A): Space-Time organization  

E-Print Network [OSTI]

We put forward a model of discrete physical space that can account for the structure of space- time, give an interpretation to the postulates of quantum mechanics and provide a possible explanation to the organization of the standard model of particles.

P. Peretto

2010-12-29T23:59:59.000Z

472

Atmospheric,OceanicandSpaceSciences Atmospheric, Oceanic & Space Sciences  

E-Print Network [OSTI]

of Michigan Space Research Building 2455 Hayward Street Ann Arbor, MI 48109-2143 aoss_um@umich.edu http Arbor ©The Regents of the University of Michigan Mark Schlissel, ex officio Sequential Graduate / under/Thermosphere Physics Planetary Magnetospheres Solar & Heliospheric Physics Space Weather Aeronomy For Faculty involved

Eustice, Ryan

473

John C. Stennis Space Center History of Stennis Space Center  

E-Print Network [OSTI]

Laboratory Propulsion Test Lead Center SSME Test Resp. 5/94 Stennis Space Center Estab. (5/88) Stennis Space · Dept. of Marine Science · Major Contractors · Pratt and Whitney Rocketdyne · Jacobs Technology Inc. · A, National Data Buoy Center · NOAA National Marine Fisheries Service · NOAA National Coastal Data Development

Waliser, Duane E.

474

UCL DEPARTMENT OF SPACE & CLIMATE PHYSICS SPACE PLASMA PHYSICS GROUP  

E-Print Network [OSTI]

" miniaturised sensors, · low cost - high return due to development derived from Solar Orbiter EAS and Tech Outline · What is L-DEPP? · How are we involved? · Low-energy Electron and Ion Analyser (LEIA) · Why is LEIA necessary? · Potential UK benefits · Summary #12;UCL DEPARTMENT OF SPACE & CLIMATE PHYSICS SPACE

Anand, Mahesh

475

Overview of Space Business Space & Integrated Defense Systems  

E-Print Network [OSTI]

collaboration Fostering of domestic space industry Enhance use space for national security purpose Focusing and Europe by becoming representatives of those foreign entities Launch vehicles Satellites Ground segment provider, SCC, along with other Mitsubishi group companies Further extended into satellite-based earth

476

Total Space Heat-  

Gasoline and Diesel Fuel Update (EIA)

Released: September, 2008 Released: September, 2008 Total Space Heat- ing Cool- ing Venti- lation Water Heat- ing Light- ing Cook- ing Refrig- eration Office Equip- ment Com- puters Other All Buildings* ........................... 3,037 115 397 384 52 1,143 22 354 64 148 357 Building Floorspace (Square Feet) 1,001 to 5,000 ........................... 386 19 43 18 11 93 7 137 8 12 38 5,001 to 10,000 .......................... 262 12 35 17 5 83 4 56 6 9 35 10,001 to 25,000 ........................ 407 20 46 44 8 151 3 53 9 19 54 25,001 to 50,000 ........................ 350 15 55 50 9 121 2 34 7 16 42 50,001 to 100,000 ...................... 405 16 57 65 7 158 2 29 6 18 45 100,001 to 200,000 .................... 483 16 62 80 5 195 1 24 Q 31 56 200,001 to 500,000 .................... 361 8 51 54 5 162 1 9 8 19 43 Over 500,000 ............................. 383 8 47 56 3 181 2 12 8 23 43 Principal Building Activity

477

Space Telescope Programs Hubble Observatory  

E-Print Network [OSTI]

Assurance/Configuration Management Mr. Christopher Scholz EAG QA Manager #12;Space Telescope Programs Hubble · COS-UCB-002 QA Implementation Plan Released December 1, 1999 · COS-UCB-003 CM Plan released DecemberSpace Telescope Programs Hubble Observatory HST-COS FUV PER 11/8/00 FUV Detector System Quality

Colorado at Boulder, University of

478

The NASA Food Commercial Space  

E-Print Network [OSTI]

The NASA Food Technology Commercial Space Center and How Your Company Can Participate space in a range of food development projects. For more information about NASA FTCSC or to arrange a presentation about the NASA FTCSC program, contact Dr. Anthony L. Pometto III Director NASA Food Technology

Lin, Zhiqun

479

INDUCTION, SPACE AND POSITIVE ETHICS  

E-Print Network [OSTI]

INDUCTION, SPACE AND POSITIVE ETHICS MARVIN E. KIRSH One may purport that ones' awareness of space of it are elemental --i.e. conceptually non reducible and that from which all emanates. The words non-ethical induction, entailing the existence of ethical induction, if compared in a corresponding manner (to

Paris-Sud XI, Université de

480

National Aeronautics and Space Administration  

E-Print Network [OSTI]

Vehicle Mission Concept Review Complete Space Vehicle SRR Complete Partial-Throttle RBS Engine TCA Test Engine Test Completed Subscale Prop Tank Assembly Review March 2014 Space Vehicle Subsystem interim's Commercial Crew Program (CCP) is facilitating the development of safe, reliable and cost-effective human

Waliser, Duane E.

Note: This page contains sample records for the topic "hydronic space heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

National Aeronautics and Space Administration  

E-Print Network [OSTI]

human-made object to enter the vast expanses between the stars. It was hardly the first history. To toast the interstellar event, TV's Stephen Colbert invited Voyager project scientist Ed Stone on his they look into deep space? For Planck, a European space telescope with technology aboard from JPL

Waliser, Duane E.

482

Total Space Heat-  

Gasoline and Diesel Fuel Update (EIA)

Revised: December, 2008 Revised: December, 2008 Total Space Heat- ing Cool- ing Venti- lation Water Heat- ing Light- ing Cook- ing Refrig- eration Office Equip- ment Com- puters Other All Buildings ............................. 91.0 33.0 7.2 6.1 7.0 18.7 2.7 5.3 1.0 2.2 7.9 Building Floorspace (Square Feet) 1,001 to 5,000 ........................... 99.0 30.7 6.7 2.7 7.1 13.9 7.1 19.9 1.1 1.7 8.2 5,001 to 10,000 .......................... 80.0 30.1 5.5 2.6 6.1 13.6 5.2 8.2 0.8 1.4 6.6 10,001 to 25,000 ........................ 71.0 28.2 4.5 4.1 4.1 14.5 2.3 4.5 0.8 1.6 6.5 25,001 to 50,000 ........................ 79.0 29.9 6.8 5.9 6.3 14.9 1.7 3.9 0.8 1.8 7.1 50,001 to 100,000 ...................... 88.7 31.6 7.6 7.6 6.5 19.6 1.7 3.4 0.7 2.0 8.1 100,001 to 200,000 .................... 104.2 39.1 8.2 8.9 7.9 22.9 1.1 2.9 Q 3.2 8.7 200,001 to 500,000 ....................

483

Total Space Heat-  

Gasoline and Diesel Fuel Update (EIA)

Revised: December, 2008 Revised: December, 2008 Total Space Heat- ing Cool- ing Venti- lation Water Heat- ing Light- ing Cook- ing Refrig- eration Office Equip- ment Com- puters Other All Buildings ............................. 91.0 33.0 7.2 6.1 7.0 18.7 2.7 5.3 1.0 2.2 7.9 Building Floorspace (Square Feet) 1,001 to 5,000 ........................... 99.0 30.7 6.7 2.7 7.1 13.9 7.1 19.9 1.1 1.7 8.2 5,001 to 10,000 .......................... 80.0 30.1 5.5 2.6 6.1 13.6 5.2 8.2 0.8 1.4 6.6 10,001 to 25,000 ........................ 71.0 28.2 4.5 4.1 4.1 14.5 2.3 4.5 0.8 1.6 6.5 25,001 to 50,000 ........................ 79.0 29.9 6.8 5.9 6.3 14.9 1.7 3.9 0.8 1.8 7.1 50,001 to 100,000 ...................... 88.7 31.6 7.6 7.6 6.5 19.6 1.7 3.4 0.7 2.0 8.1 100,001 to 200,000 .................... 104.2 39.1 8.2 8.9 7.9 22.9 1.1 2.9 Q 3.2 8.7 200,001 to 500,000 ....................

484

University of California, Santa Cruz Space Management Principles  

E-Print Network [OSTI]

for Academic Office Space...................................................... 3 Criteria for Library Space#12;#12;University of California, Santa Cruz Space Management Principles Section Page Space ..................................................................................... 1 3. Space Management Principles

California at Santa Cruz, University of

485

Space Travel Space Travel: Past, Present and Future  

E-Print Network [OSTI]

;#12;NASA's Planetary Exploration Program ...and dropped probes into planet atmospheres, flown through comet tails, landed on 1 planet, two moons, and an asteroid. #12;Space is being opened to the private sector

Shirley, Yancy

486

GSLIS Space Policy September 29, 2011  

E-Print Network [OSTI]

GSLIS Space Policy September 29, 2011 The Graduate School of Library and Information Science. Offices 2. Classrooms and Meeting space 3. LEEP studios 4. Computer Lab space 5. Public space 6. Storage space without keys--for example, cubicles in public areas--cannot be considered private property

Gilbert, Matthew

487

DREAM tool increases space weather predictions  

E-Print Network [OSTI]

and an interactive user interface to support satellite operators and space weather forecasters. For national security- 1 - DREAM tool increases space weather predictions April 13, 2012 Predicting space weather in an article published in Space Weather, a journal of the American Geophysical Union. Space environment and its

488

BNL NASA Space Radiation Laboratory  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Purpose: To use beams of heavy ions provided by the Booster accelerator at Brookhaven to study the effects of simulated space radiation on biological and physical systems, with the goal of developing methods and materials to reduce the risk to human beings on prolonged space missions of the effects of ionizing radiation Sponsor: National Aeronautics and Space Administration (NASA) Project cost $34 million over 4 years Operating costs Nearly $8 million per year in 2007 Features * beams of heavy ions extracted from the Booster accelerator with masses and energies similar to the cosmic rays encountered in space: * 1-billion electron volt (GeV)/nucleon iron-56 * 0.3-GeV/nucleon gold-97 * 0.6-GeV/nucleon silicon-28 * 1-GeV/nucleon protons * 1-GeV/nucleon titanium

489

Insulation For Earth And Space  

Science Journals Connector (OSTI)

According to National Aeronautics & Space Administration scientist Mary Ann B. Meador, before sending people or larger vehicles to Mars, scientists must develop insulating materials to counter the planet’s exotic environment. ...

LAUREN WOLF

2012-09-16T23:59:59.000Z

490

Environmental Design Space model assessment  

E-Print Network [OSTI]

The Environmental Design Space (EDS) is a multi-disciplinary design tool used to explore trade-offs among aircraft fuel burn, emissions, and noise. This thesis uses multiple metrics to assess an EDS model of a Boeing 777 ...

Spindler, Phillip Michael

2007-01-01T23:59:59.000Z

491

Nuclear Propulsion in Space (1968)  

ScienceCinema (OSTI)

Project NERVA was an acronym for Nuclear Engine for Rocket Vehicle Application, a joint program of the U.S. Atomic Energy Commission and NASA managed by the Space Nuclear Propulsion Office (SNPO) at the Nuclear Rocket Development Station in Jackass Flats, Nevada U.S.A. Between 1959 and 1972, the Space Nuclear Propulsion Office oversaw 23 reactor tests, both the program and the office ended at the end of 1972.

None

2014-06-17T23:59:59.000Z

492

(Nuclear power engineering in space)  

SciTech Connect (OSTI)

The principal purpose of this trip was to participate in the Anniversary Specialist Conference on Nuclear Power Engineering in Space hosted by the USSR Ministry of Atomic Power Engineering and Industry. The conference was held in Obninsk, USSR. A secondary purpose of the trip was to meet with the French Commissariat A L'Energie Atomique in Paris regarding the status of their space power program.

Cooper, R.H. Jr.

1990-06-18T23:59:59.000Z

493

Nuclear Propulsion in Space (1968)  

SciTech Connect (OSTI)

Project NERVA was an acronym for Nuclear Engine for Rocket Vehicle Application, a joint program of the U.S. Atomic Energy Commission and NASA managed by the Space Nuclear Propulsion Office (SNPO) at the Nuclear Rocket Development Station in Jackass Flats, Nevada U.S.A. Between 1959 and 1972, the Space Nuclear Propulsion Office oversaw 23 reactor tests, both the program and the office ended at the end of 1972.

None

2012-06-23T23:59:59.000Z

494

Space Weather and Hazards to Application Satellites  

Science Journals Connector (OSTI)

“Space weather” is defined by the US National Space Weather Program as referring to “conditions on the ... health.” From the viewpoint of an application satellite, the space environment is a hostile, ... is thus ...

Dr. Michael J. Rycroft

2013-01-01T23:59:59.000Z

495

Sustainable Spaces Inc | Open Energy Information  

Open Energy Info (EERE)

Spaces Inc Jump to: navigation, search Name: Sustainable Spaces Inc. Place: San Francisco, California Zip: 94103 Sector: Carbon Product: California-based provider of energy audits...

496

The analysis of potential space tourism market.  

E-Print Network [OSTI]

?? In December of 2004, RIT Professor C.J. Wallington and students in the space tourism development course (winter 2004/ 2005) conducted a space tourism market… (more)

Sankovic, Sandra

2007-01-01T23:59:59.000Z

497

The analysis of potential space tourism market.  

E-Print Network [OSTI]

??In December of 2004, RIT Professor C.J. Wallington and students in the space tourism development course (winter 2004/ 2005) conducted a space tourism market survey.… (more)

Sankovic, Sandra

2007-01-01T23:59:59.000Z

498

DREAM tool increases space weather predictions  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

using real-time space weather observations and an interactive user interface to support satellite operators and space weather forecasters. For national security applications,...

499

Integration of space weather into space situational awareness  

SciTech Connect (OSTI)

Rapid assessment of space weather effects on satellites is a critical step in anomaly resolution and satellite threat assessment. That step, however, is often hindered by a number of factors including timely collection and delivery of space weather data and the inherent com plexity of space weather information. As part of a larger, integrated space situational awareness program, Los Alamos National Laboratory has developed prototype operational space weather tools that run in real time and present operators with customized, user-specific information. The Dynamic Radiation Environment Assimilation Model (DREAM) focuses on the penetrating radiation environment from natural or nuclear-produced radiation belts. The penetrating radiation environment is highly dynamic and highly orbit-dependent. Operators often must rely only on line plots of 2 MeV electron flux from the NOAA geosynchronous GOES satellites which is then assumed to be representative of the environment at the satellite of interest. DREAM uses data assimilation to produce a global, real-time, energy dependent specification. User tools are built around a distributed service oriented architecture (SOA) which will allow operators to select any satellite from the space catalog and examine the environment for that specific satellite and time of interest. Depending on the application operators may need to examine instantaneous dose rates and/or dose accumulated over various lengths of time. Further, different energy thresholds can be selected depending on the shielding on the satellite or instrument of interest. In order to rapidly assess the probability that space weather was the cause of anomalous operations, the current conditions can be compared against the historical distribution of radiation levels for that orbit. In the simplest operation a user would select a satellite and time of interest and immediately see if the environmental conditions were typical, elevated, or extreme based on how often those conditions occur in that orbit. This allows users to rapidly rule in or out environmental causes of anomalies. The same user interface can also allow users to drill down for more detailed quantitative information. DREAM can be run either from a distributed web-based user interface or as a stand-alone application for secure operations. In this paper we discuss the underlying structure of the DREAM model and demonstrate the user interface that we have developed . We also present some prototype data products and user interfaces for DREAM and discuss how space environment information can be seamlessly integrated into operational SSA systems.

Reeves, Geoffrey D [Los Alamos National Laboratory

2010-11-09T23:59:59.000Z

500

Spacings of Nuclear Energy Levels  

Science Journals Connector (OSTI)

The distribution of spacings of nuclear energy levels in many heavy nuclei at an excitation energy of 5 to 9 Mev is obtained by careful correction of the observed distributions for the effect of failure to observe all levels. Results of transmission measurements on U234 and U236, as measured with the Brookhaven fast chopper, are presented. The experimental spacings of the zero-spin nuclides are considered first since all the levels from slow neutron capture have the same spin. The results show a deficiency of small spacings relative to the exponential distribution, which corresponds to a random occurrence of levels. In the analysis it is shown that there is no local correlation of neutron widths and level spacings. The "level repulsion" effect is also found for the nuclides of nonzero spin, for which the data are more abundant but the analysis is complicated by the presence of two spin systems. The distribution obtained is in agreement with one suggested by Wigner based on a probability of level occurrence proportional to the spacing S. The corrections here developed are also applied to the reduced neutron width distribution and this corrected distribution is in good agreement with the Porter-Thomas distribution.

John A. Harvey and D. J. Hughes

1958-01-15T23:59:59.000Z