Powered by Deep Web Technologies
Note: This page contains sample records for the topic "hvac zone summary" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Adaptive HVAC zone modeling for sustainable buildings  

Science Journals Connector (OSTI)

Control of energy flows within a building is critical to achieving optimal performance of heating, ventilation and air-conditioning (HVAC) systems. To design optimal HVAC control strategies, a dynamic model of the HVAC system – particularly the building zones that it services – is essential. As analysis of building energy consumption is facilitated by the accurate prediction of indoor environmental conditions, techniques that dynamically model HVAC zones are crucial, and as such, is an active area of research. This paper focuses on real-time HVAC zone model fitting and prediction techniques based on physical principles, as well as the use of genetic algorithms for optimization. The proposed approach is validated by comparing real-time HVAC zone model fitting and prediction against the corresponding experimental measurements. In addition, comparison with prediction results using an algorithm based on feedback-delayed Kalman filters has demonstrated the superiority of the proposed approach in terms of prediction accuracy.

Glenn Platt; Jiaming Li; Ronxin Li; Geoff Poulton; Geoff James; Josh Wall

2010-01-01T23:59:59.000Z

2

Modeling Building Thermal Response to HVAC Zoning Virginia Smith  

E-Print Network (OSTI)

Modeling Building Thermal Response to HVAC Zoning Virginia Smith Department of Computer Science HVAC systems account for 38% of building energy usage. Studies have indicated at least 5-15% waste due to unoccu- pied spaces being conditioned. Our goal is to minimize this waste by retrofitting HVAC systems

Whitehouse, Kamin

3

RoomZoner: Occupancy-based Room-Level Zoning of a Centralized HVAC System  

E-Print Network (OSTI)

RoomZoner: Occupancy-based Room-Level Zoning of a Centralized HVAC System Tamim Sookoor & Kamin. In this paper we present a CPS that enables a centralized Heating, Ventila- tion, and Air Conditioning (HVAC application due to residential HVAC systems ac- counting for over 15% of all U.S. energy usage, making it one

Whitehouse, Kamin

4

Feasibility of Retrofitting Centralized HVAC Systems for Room-Level Zoning Tamim Sookoor, Brian Holben, Kamin Whitehouse  

E-Print Network (OSTI)

Feasibility of Retrofitting Centralized HVAC Systems for Room-Level Zoning Tamim Sookoor, Brian {sookoor,bnh4k,whitehouse}@cs.virginia.edu Abstract--Heating, ventilation, and cooling (HVAC) accounts's largest energy consumers. Many attempts have been made to optimize the control of HVAC systems

Whitehouse, Kamin

5

CO 2 - Based Demand-Controlled Ventilation Control Strategies for Multi-Zone HVAC Systems  

E-Print Network (OSTI)

CO 2-based demand-controlled ventilation DCV strategy offers a great opportunity to reduce energy consumption in HVAC systems while providing the required ventilation. However, implementing CO 2-based DCV under ASHRAE 62.1.2004 through 2010...

Nassif, N.

2011-01-01T23:59:59.000Z

6

A robust CO2-based demand-controlled ventilation control strategy for multi-zone HVAC systems  

Science Journals Connector (OSTI)

There have been increasingly growing concerns over the quality of the air inside buildings and the associated energy use. The CO2-based demand-controlled ventilation DCV is one of the strategies that could offer a great opportunity to reduce energy consumption in HVAC systems. However, implementing CO2-based DCV under ASHRAE Standard 62.1 2004–2010 is not simple as it was under previous versions due to the changes in breathing-zone ventilating rate calculations. Thus, this paper provides insight into the performance of a multi-zone VAV system under different operating and ventilation conditions, discusses the difficulties in the CO2-based DCV, and proposes a robust DCV strategy based on the supply air CO2 concentration. The proposed strategy offers great benefits in terms of better indoor air control and improved energy efficiency. To evaluate the proposed strategy, energy simulations were performed on various USA locations and for a typical two-story office building conditioned by a VAV system. The results show that a significant energy saving could be achieved by implementing the proposed strategy as compared to the design-occupancy ASHRAE Standard 62.1 2010 multi-zone procedure and the amount of saving that could be up to 23% depends mainly on locations and the actual occupancy profile.

Nabil Nassif

2012-01-01T23:59:59.000Z

7

Vadose Zone Transport Field Study: Summary Report  

SciTech Connect

From FY 2000 through FY 2003, a series of vadose zone transport field experiments were conducted as part of the U.S. Department of Energy’s Groundwater/Vadose Zone Integration Project Science and Technology Project, now known as the Remediation and Closure Science Project, and managed by the Pacific Northwest National Laboratory (PNNL). The series of experiments included two major field campaigns, one at a 299-E24-11 injection test site near PUREX and a second at a clastic dike site off Army Loop Road. The goals of these experiments were to improve our understanding of vadose zone transport processes; to develop data sets to validate and calibrate vadose zone flow and transport models; and to identify advanced monitoring techniques useful for evaluating flow-and-transport mechanisms and delineating contaminant plumes in the vadose zone at the Hanford Site. This report summarizes the key findings from the field studies and demonstrates how data collected from these studies are being used to improve conceptual models and develop numerical models of flow and transport in Hanford’s vadose zone. Results of these tests have led to a better understanding of the vadose zone. Fine-scale geologic heterogeneities, including grain fabric and lamination, were observed to have a strong effect on the large-scale behavior of contaminant plumes, primarily through increased lateral spreading resulting from anisotropy. Conceptual models have been updated to include lateral spreading and numerical models of unsaturated flow and transport have revised accordingly. A new robust model based on the concept of a connectivity tensor was developed to describe saturation-dependent anisotropy in strongly heterogeneous soils and has been incorporated into PNNL’s Subsurface Transport Over Multiple Phases (STOMP) simulator. Application to field-scale transport problems have led to a better understanding plume behavior at a number of sites where lateral spreading may have dominated waste migration (e.g. BC Cribs and Trenches). The improved models have been also coupled with inverse models and newly-developed parameter scaling techniques to allow estimation of field-scale and effective transport parameters for the vadose zone. The development and utility of pedotransfer functions for describing fine-scale hydrogeochemical heterogeneity and for incorporating this heterogeneity into reactive transport models was explored. An approach based on grain-size statistics appears feasible and has been used to describe heterogeneity in hydraulic properties and sorption properties, such as the cation exchange capacity and the specific surface area of Hanford sediments. This work has also led to the development of inverse modeling capabilities for time-dependent, subsurface, reactive transport with transient flow fields using an automated optimization algorithm. In addition, a number of geophysical techniques investigated for their potential to provide detailed information on the subtle changes in lithology and bedding surfaces; plume delineation, leak detection. High-resolution resistivity is now being used for detecting saline plumes at several waste sites at Hanford, including tank farms. Results from the field studies and associated analysis have appeared in more than 46 publications generated over the past 4 years. These publications include test plans and status reports, in addition to numerous technical notes and peer reviewed papers.

Ward, Andy L.; Conrad, Mark E.; Daily, William D.; Fink, James B.; Freedman, Vicky L.; Gee, Glendon W.; Hoversten, Gary M.; Keller, Jason M.; Majer, Ernest L.; Murray, Christopher J.; White, Mark D.; Yabusaki, Steven B.; Zhang, Z. F.

2006-07-31T23:59:59.000Z

8

CALIFORNIA ENERGY Small HVAC Problems and Potential  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Small HVAC Problems and Potential Savings Reports Summary of Problems of the Integrated Design of Small Commercial HVAC Systems research project. The reports are a result of funding: Productivity and Interior Environments Integrated Design of Large Commercial HVAC Systems Integrated Design

9

HVAC | OpenEI  

Open Energy Info (EERE)

HVAC HVAC Dataset Summary Description The following data-set is for a benchmark residential home for all TMY3 locations across all utilities in the US. The data is indexed by utility service provider which is described by its "unique" EIA ID ( Source National Renewable Energy Laboratory Date Released April 05th, 2012 (2 years ago) Date Updated April 06th, 2012 (2 years ago) Keywords AC apartment CFL coffeemaker Computer cooling cost demand Dishwasher Dryer Furnace gas HVAC Incandescent Laptop load Microwave model NREL Residential television tmy3 URDB Data text/csv icon Residential Cost Data for Common Household Items (csv, 14.5 MiB) Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Annually Time Period License License Open Data Commons Public Domain Dedication and Licence (PDDL)

10

Renovating Residential HVAC Systems HVAC Systems  

E-Print Network (OSTI)

- 1 - LBNL 57406 Renovating Residential HVAC Systems HVAC Systems J.A. McWilliams and I.S. Walker and Air Conditioning), and Stacy Hunt and Ananda Harzell (IBACOS). #12;- 3 - Renovating Residential HVAC Guideline for Residential HVAC Retrofits (http

11

Department of Mechanical Engineering Spring 2012 HVAC Filter Sensor -Global  

E-Print Network (OSTI)

PENNSTATE Department of Mechanical Engineering Spring 2012 HVAC Filter Sensor - Global Overview The purpose of this project is to develop a heating, ventilation, and air conditioning (HVAC) monitoring a residential, forced flow, multi-zone HVAC filter needs to be replaced, and then alerts the users

Demirel, Melik C.

12

Best Practices for Energy Efficient Cleanrooms Efficient HVAC Systems: Variable-Speed-Drive Chillers  

E-Print Network (OSTI)

LBNL-58636 Best Practices for Energy Efficient Cleanrooms Efficient HVAC Systems: Variable Efficient Cleanrooms Efficient HVAC Water Systems: Variable-Speed-Drive Chillers Tengfang Xu Contents HVAC.................................................................................................................................... 6 #12;HVAC Water Systems Variable-Speed-Drive Chillers Summary Cleanroom energy benchmarking data

13

Modeling Building Thermal Response to HVAC Virginia Smith, Tamim Sookoor, and Kamin Whitehouse  

E-Print Network (OSTI)

Modeling Building Thermal Response to HVAC Zoning Virginia Smith, Tamim Sookoor, and Kamin,sookoor,whitehouse}@virginia.edu Abstract. HVAC systems account for 38% of building energy usage. Studies have indicated at least 5 HVAC systems to enable room-level zoning where each room is conditioned in- dividually based on its

Whitehouse, Kamin

14

HVAC Market Study:  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC Market Study: Understanding how energy efficient products get to market Fall 2014 through Winter 2015 Research Manager: Carrie Cobb, clcobb@bpa.gov, 503-230-4985 HVAC systems...

15

DOE New Madrid Seismic Zone Electric Utility Workshop Summary Report- August 2010  

Energy.gov (U.S. Department of Energy (DOE))

This paper provides a brief summary of the potential impacts that a devastating earthquake within the New Madrid Seismic Zone would have on the Nation’s critical energy infrastructure. It concludes by addressing the potential major issues that should be considered in order to improve response and restoration efforts following an event of this magnitude.

16

Comparison of dust from HVAC filters, indoor surfaces, and indoor air Federico Noris*  

E-Print Network (OSTI)

Comparison of dust from HVAC filters, indoor surfaces, and indoor air Federico Noris* , Kerry A and Environmental Engineering * Corresponding email: Fedenoris@mail.utexas.edu SUMMARY HVAC filters are long heavy metal (Pb, Cd and As) concentrations. HVAC filter microbial concentrations appear to be consistent

Siegel, Jeffrey

17

HVAC Maintenance and Technologies  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC - HVAC - Maintenance and Technologies Federal Utility Partnership Working Group Meeting Providence, Rhode Island April 15, 2010 BY Ramin Faramarzi, P.E. Technology Test Centers (TTC) Design and Engineering Services Southern California Edison (SCE) www.sce.com/rttc 2 Outline * Introduction to SCE's TTC * Overview of energy challenges in California (CA) * Role of HVAC in CA's energy and demand equations * Factors affecting HVAC performance * Focus on SCE's research on maintenance faults * Next generation of HVAC equipment * HVAC technologies on SCE's TTC radar * Black boxes - do they all work? 3 SCE's Technology Test Centers * SCE applied research facilities located in Irwindale, CA comprised of 3 test beds: * Refrigeration * HVAC * Lighting * Coming Soon! - A new ZNE lab 4 Refrigeration Testing

18

HVAC Installed Performance  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC Installed Performance HVAC Installed Performance ESI, Tim Hanes Context * The building envelope has historically been the focus in residential homes. * The largest consumer of energy in residential homes is typically the HVAC system. * Testing the performance of the HVAC system has not been pursued to its full potential. Technical Approach * Currently very little performance testing is being done to the HVAC system. * The only way to know if a HVAC system is operating correctly is to measure the Btu/h. * This should be done at the equipment and at the the system. Recommended Guidance * Training of HVAC technicians, installers, and salespeople is a must. * If only the technician is trained than implementing the change will not happen. * Public awareness of proper installation and its

19

HVAC Maintenance and Technologies  

Energy.gov (U.S. Department of Energy (DOE))

Presentation covers the HVAC maintenance and technologies, and is given at the Spring 2010 Federal Utility Partnership Working Group (FUPWG) meeting in Providence, Rhode Island.

20

CALIFORNIA ENERGY Large HVAC Building  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Large HVAC Building Survey Information Database of Buildings over 100 Design of Large Commercial HVAC Systems research project, one of six research elements in the Integrated Design of Large Commercial HVAC Systems Integrated Design of Small Commercial HVAC Systems Integrated

Note: This page contains sample records for the topic "hvac zone summary" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Application of Multizone HVAC Control Using Wireless Sensor Networks and Actuating Vent Registers  

E-Print Network (OSTI)

Most residential heating, ventilating, and air conditioning (HVAC) systems are designed to treat the home as a single zone. Single zone control consists of one thermostat, in a central area of the house that controls the HVAC operation. In a single...

Watts, W.; Koplow, M.; Redfern, A.; Wright, P.

2007-01-01T23:59:59.000Z

22

Review of modeling methods for HVAC systems  

Science Journals Connector (OSTI)

Abstract This work presents the literature review of the methods used to model the heating, ventilation, and air conditioning (HVAC) systems. The model development is necessary for the study of the energy consumption of HVAC systems. Models are also required to simulate the different supervisory and local loop control strategies to improve the energy consumption efficiency. HVAC systems have complex structures consisting of heat and mass transfer equipment such as chiller, boiler, heating/cooling coils, and supply air ducts. HVAC systems also consist of several sensors and controllers for regulating the controllable variables such as zone temperature, supply air temperature, supply air fan speed, duct static pressure, and chilled water temperature at their set-points. To predict the energy consumption by the HVAC systems accurately, one needs to model the individual components either from the measured data or based on the knowledge of the underlying physical phenomenon. This results in three broad classes of the models known as data driven, physics based, and grey box models. In this paper, major data driven, physics based, and grey box modeling techniques reported in the recent literature are reviewed.

Abdul Afram; Farrokh Janabi-Sharifi

2014-01-01T23:59:59.000Z

23

HVAC Installed Performance  

Energy.gov (U.S. Department of Energy (DOE))

This presentation was given at the Summer 2012 DOE Building America meeting on July 25, 2012, and addressed the question HVAC proper installation energy savings: over-promising or under-delivering?"

24

Definition: HVAC | Open Energy Information  

Open Energy Info (EERE)

HVAC HVAC Jump to: navigation, search Dictionary.png HVAC An abbreviation for the heating, ventilation, and air-conditioning system; the system or systems that condition air in a building.[1] View on Wikipedia Wikipedia Definition HVAC is the technology of indoor and vehicular environmental comfort. HVAC system design is a subdiscipline of mechanical engineering, based on the principles of thermodynamics, fluid mechanics, and heat transfer. Refrigeration is sometimes added to the field's abbreviation as HVAC&R or HVACR, or ventilating is dropped as in HACR (such as the designation of HACR-rated circuit breakers). HVAC is important in the design of medium to large industrial and office buildings such as skyscrapers and in marine environments such as aquariums, where safe and

25

CALIFORNIA ENERGY Large HVAC Energy Impact Report  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Large HVAC Energy Impact Report Statewide Energy Impact Report are part of the Integrated Design of Large Commercial HVAC Systems research project. The reports: Productivity and Interior Environments Integrated Design of Large Commercial HVAC Systems Integrated Design

26

Advanced HVAC Systems | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

HVAC Systems Advanced HVAC Systems Lead Performer: Oak Ridge National Laboratory - Oak Ridge, TN Partners: -- Indian Institute of Technology Bombay - Maharashtra, India -- Malviya...

27

HVAC: Maintaining HVAC equipment with air intake filters  

Science Journals Connector (OSTI)

Airborne debris, such as domestic waste, leaves, pollen, insects and even plastic carrier bags is the leading cause of fouling and clogging of cooling towers, heat exchangers, air cooled chillers and other HVAC systems. Richard Betts, managing director of UK-based RAB Specialist Engineers, provides Filtration+Separation with some practical advice on how to maintain HVAC equipment.

Richard Betts

2013-01-01T23:59:59.000Z

28

HVAC Improvements for Existing Houses  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC Improvements for Existing Houses HVAC Improvements for Existing Houses Speaker(s): Chryséis Bovagnet Date: September 5, 2002 - 12:00pm Location: Bldg. 90 Many older houses in the US are either not well designed from a thermal point of view or have HVAC (Heating Ventilation and Air Conditioning) systems in need of repairs or improvements. The building envelopes tend to have poor insulation and lots of leakage, and the HVAC systems are inefficient. The cooling/heating equipment is often located outside of the conditioned space (e.g. in attics or crawlspaces) with ducts that leak and have poor insulation, which cause energy loss and bad occupant comfort on peak days or in extreme climates. We developed a series of retrofits that will allow us to reduce the energy consumption of residential HVAC

29

Summary  

NLE Websites -- All DOE Office Websites (Extended Search)

Project Summary Project Summary HELP Index Summary Scenario References Student Pages Subject/Content Area: Ecology and Data Collection Target Audience: This project is designed for upper intermediate grade students. Access to a river or stream is critical to the success of this project. Students need access to the Internet and data collection software. Project Goals: When presented with an environmental problem on a local river, students will use their knowledge of river ecology to develop an action plan. Learner Outcomes: The students will be able to Use river monitoring equipment to collect river monitoring data, including biological, physical,and chemical data. Design a project that aids the class in accompolishing one of four goals: Raising smallmouth bass Creating a stream habitat in an aquarium

30

HVAC's Variable Refrigerant Flow (VRF) Technology  

E-Print Network (OSTI)

1 Comfort by Design Steve Jones Commercial Sales Manager for Mitsubishi Southwest Business Unit HVAC?s Variable Refrigerant Flow (VRF) Technology HVAC Industry Overview HVAC Market Dollar Volume $18 Billion Source:;NABH Research....2M Systems Ductless is a small percent of the U.S. HVAC market but current building and energy usage trends indicate a large growth opportunity Determining the Proper Application Worldwide Usage-Opportunity Window Unitary Chillers...

Jones, S.

2012-01-01T23:59:59.000Z

31

Strategy Guideline: HVAC Equipment Sizing  

SciTech Connect

The heating, ventilation, and air conditioning (HVAC) system is arguably the most complex system installed in a house and is a substantial component of the total house energy use. A right-sized HVAC system will provide the desired occupant comfort and will run efficiently. This Strategy Guideline discusses the information needed to initially select the equipment for a properly designed HVAC system. Right-sizing of an HVAC system involves the selection of equipment and the design of the air distribution system to meet the accurate predicted heating and cooling loads of the house. Right-sizing the HVAC system begins with an accurate understanding of the heating and cooling loads on a space; however, a full HVAC design involves more than just the load estimate calculation - the load calculation is the first step of the iterative HVAC design procedure. This guide describes the equipment selection of a split system air conditioner and furnace for an example house in Chicago, IL as well as a heat pump system for an example house in Orlando, Florida. The required heating and cooling load information for the two example houses was developed in the Department of Energy Building America Strategy Guideline: Accurate Heating and Cooling Load Calculations.

Burdick, A.

2012-02-01T23:59:59.000Z

32

HVAC efficiency: Can filter selection reduce HVAC energy costs?  

Science Journals Connector (OSTI)

In a society becoming more aware of the effects of energy consumption, Zoe Grainge takes a look at whether filter efficiency can go some way to ease the energy burden of HVAC systems.

Zoe Grainge

2007-01-01T23:59:59.000Z

33

Summary  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Golden Field Office Golden Field Office Office of Energy Efficiency and Renewable Energy DOE/EIS-0407D September 2009 Draft Environmental Impact Statement for the Proposed Abengoa Biorefinery Project near Hugoton, Stevens County, Kansas Summary Cover photos courtesy of (left to right): Southeast Renewable Fuels, LLC DOE National Renewable Energy Laboratory Public domain U.S. Department of Energy Golden Field Office Office of Energy Efficiency and Renewable Energy DOE/EIS-0407D September 2009 Draft Environmental Impact Statement for the Proposed Abengoa Biorefinery Project near Hugoton, Stevens County, Kansas Summary COVER SHEET RESPONSIBLE AGENCY: U.S. Department of Energy (DOE) COOPERATING AGENCY: The U.S. Department of Agriculture-Rural Development is a cooperating agency in the preparation of the Abengoa Biorefinery Project EIS.

34

Summary  

NLE Websites -- All DOE Office Websites (Extended Search)

SPACE SPACE Project Summary HELP Index Summary Scenario Internet Links Student Pages Subject/Content Area: Interdisciplinary: Science - astronomy; Math - problem-solving and measurement; Art; Social Studies - current events; and Language Arts - reference. skills Target Audience: Middle school students, 7th grade, all levels Project Goals: A collaborative, seven-to-ten weeks investigation of the space program, specifically space stations, its impact on our lives and the world Learner Outcomes: Students will be able to: Gather information and use decision-making skills to evaluate this information. Establish connections and to develop decision-making skills about science and technology. Identify and state a problem; design, implement, and evaluate the solution. Gather and use information for research purposes.

35

ESPC ENABLE: ECM Summary  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

ESPC ENABLE: ECM Summary ESPC ENABLE: ECM Summary ECM Included Not Included Lighting * Lamps, Ballasts, Fixtures * Controls: Occupancy, Day lighting (on/off, dimming) * Solar Lighting (off-grid installations allowed) Water * Sanitary plumbing fixtures: sinks, toilets, urinals, showers * Irrigation * Leak repair * Domestic/commercial hot water heaters * Water based appliances: dishwasher, ice machine, clothes washer, etc. * Heating/Cooling system improvements (cooling towers, once through cooling, condensate reclaim) HVAC Controls Whole building control strategies including: * Time/Temperature Set-back * Demand/Night Ventilation * Advanced Controls 1 : Energy Management Control Systems (EMCS) / Building Automation Systems (BAS) HVAC Equipment Basic whole building/system one-for-one replacement

36

ESPC ENABLE: ECM Summary  

NLE Websites -- All DOE Office Websites (Extended Search)

ESPC ENABLE: ECM Summary ESPC ENABLE: ECM Summary ECM Included Not Included Lighting * Lamps, Ballasts, Fixtures * Controls: Occupancy, Day lighting (on/off, dimming) * Solar Lighting (off-grid installations allowed) Water * Sanitary plumbing fixtures: sinks, toilets, urinals, showers * Irrigation * Leak repair * Domestic/commercial hot water heaters * Water based appliances: dishwasher, ice machine, clothes washer, etc. * Heating/Cooling system improvements (cooling towers, once through cooling, condensate reclaim) HVAC Controls Whole building control strategies including: * Time/Temperature Set-back * Demand/Night Ventilation * Advanced Controls 1 : Energy Management Control Systems (EMCS) / Building Automation Systems (BAS) HVAC Equipment Basic whole building/system one-for-one replacement

37

Summary  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Imperial-Mexicali DEIS Imperial-Mexicali DEIS S-1 May 2004 SUMMARY S.1 BACKGROUND S.1.1 Previous NEPA Review and Litigation Baja California Power, Inc. (hereafter referred to as Intergen), applied to the U.S. Department of Energy (DOE) on February 27, 2001, to construct a double-circuit, 230,000-volt (230-kV) transmission line across the U.S.-Mexico border. In a separate but similar proceeding, Sempra Energy Resources (hereafter referred to as Sempra) applied to DOE for a Presidential permit on March 7, 2001, also proposing to construct a double-circuit, 230-kV transmission line across the U.S.-Mexico border. Executive Order (E.O.) 10485 (September 9, 1953), as amended by E.O. 12038 (February 7, 1978), requires that a Presidential permit be issued by DOE before electric transmission facilities may be constructed, operated, maintained,

38

SIMULATION OF RESIDENTIAL HVAC SYSTEM PERFORMANCE  

E-Print Network (OSTI)

1 LBNL-47622 SIMULATION OF RESIDENTIAL HVAC SYSTEM PERFORMANCE Walker, I., Siegel, J ..................................................... 9 #12;3 ABSTRACT In many parts of North America residential HVAC systems are installed outside of the simulations is that they are dynamic - which accounts for cyclic losses from the HVAC system and the effect

39

Energirigtige pumpekoblinger i HVAC-systemer  

E-Print Network (OSTI)

Energirigtige pumpekoblinger i HVAC-systemer PSO 2003 - FORSKNING & UDVIKLING I EFFEKTIV energieffektive HVAC-aggregater #12;InformationomProjektnr.:335-021 PROCESSEN: Projektet er gennemført af en reguleringsprincipper, mens Exhausto har leveret HVAC-aggregat og knowhow inden for klimasystemer. Grundfos

40

MODELING PARTICLE DEPOSITION ON HVAC HEAT EXCHANGERS  

E-Print Network (OSTI)

LBNL-49339 MODELING PARTICLE DEPOSITION ON HVAC HEAT EXCHANGERS J.A. Siegel1,3 * and W.W. Nazaroff2 Department of Energy under contract DE-AC03-76SF00098. #12;MODELING PARTICLE DEPOSITION ON HVAC HEAT, such as discontinuities in the fins, are hypothesized to be responsible for the discrepancy. INDEX TERMS HVAC, Fouling

Note: This page contains sample records for the topic "hvac zone summary" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

PROJECT REPORT HVAC EQUIPMENT DEMOGRAPHICS AND CAPACITY  

E-Print Network (OSTI)

PROJECT REPORT HVAC EQUIPMENT DEMOGRAPHICS AND CAPACITY ANALYSIS TOOLS APPLICABLE TO MULTI Commercial HVAC Design Process 12 5.0 Conclusion 18 6.0 References 19 TABLE OF CONTENTS SECTIONS #12;MULTI performance by collectively improving the enve- lope, lighting and HVAC systems. The primary goals of the UC

California at Davis, University of

42

CALIFORNIA ENERGY Small HVAC Database Of Monitored  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Small HVAC Database Of Monitored Information Database of Compiled of the Integrated Design of Small Commercial HVAC Systems research project. The reports are a result of funding: Productivity and Interior Environments Integrated Design of Large Commercial HVAC Systems Integrated Design

43

CALIFORNIA ENERGY Small HVAC System Design Guide  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Small HVAC System Design Guide DESIGNGUIDELINES October 2003 500;#12;Small HVAC System Design Guide Acknowledgements i Acknowledgements The products and outcomes presented; Darren Goody, PECI, Design Guide review. #12;Small HVAC System Design Guide Preface ii Preface The Small

44

Development Practice in HVAC Controls  

NLE Websites -- All DOE Office Websites (Extended Search)

Development Practice in HVAC Controls Development Practice in HVAC Controls Speaker(s): John Zhou Date: April 11, 2011 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Philip Haves The presentation will introduce development tools and design considerations used in HVAC controls development. Controls development use simulation, lab testing and field trial at different phases of the project cycle to improve control performance and to achieve rapid development. Development starts with simulation to originate and define algorithm concept. The concept is then implemented in a prototype controller, and tested in lab environment. The concept is refined and verified by analyzing lab results. In the final phase of development, controllers with refined and verified algorithms are installed in field trial sites to ensure system integration and to confirm

45

Ozone removal by HVAC filters  

Science Journals Connector (OSTI)

Residential and commercial HVAC filters that have been loaded with particles during operation in the field can remove ozone from intake or recirculated air. However, knowledge of the relative importance of HVAC filters as a removal mechanism for ozone in residential and commercial buildings is incomplete. We measured the ozone removal efficiencies of clean (unused) fiberglass, clean synthetic filters, and field-loaded residential and commercial filters in a controlled laboratory setting. For most filters, the ozone removal efficiency declined rapidly but converged to a non-zero (steady-state) value. This steady-state ozone removal efficiency varied from 0% to 9% for clean filters. The mean steady-state ozone removal efficiencies for loaded residential and commercial filters were 10% and 41%, respectively. Repeated exposure of filters to ozone following a 24-h period of no exposure led to a regeneration of ozone removal efficiency. Based on a theoretical scaling analysis of mechanisms that are involved in the ozone removal process, we speculate that the steady-state ozone removal efficiency is limited by reactant diffusion out of particles, and that regeneration is due to internal diffusion of reactive species to sites available to ozone for reaction. Finally, by applying our results to a screening model for typical residential and commercial buildings, HVAC filters were estimated to contribute 22% and 95%, respectively, of total ozone removal in HVAC systems.

P. Zhao; J.A. Siegel; R.L. Corsi

2007-01-01T23:59:59.000Z

46

Software tools for HVAC research  

Science Journals Connector (OSTI)

Energy saving methods can be employed to reduce energy consumption in buildings, or improve indoor thermal conditions. An example of those methods is the use of permeable coverings, but there are other important parameters like thermal inertia. To understand ... Keywords: Building, Computer, Design, Energy saving, HVAC, Software tools

José A. Orosa; Armando C. Oliveira

2011-10-01T23:59:59.000Z

47

STATE OF CALIFORNIA CERTIFICATE OF COMPLIANCE, PRESCRIPTIVE HVAC ALTERATIONS  

E-Print Network (OSTI)

STATE OF CALIFORNIA CERTIFICATE OF COMPLIANCE, PRESCRIPTIVE HVAC ALTERATIONS CEC-MECH-1C-ALT-HVAC (Revised 07/10) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE MECH-1C-ALT-HVAC Prescriptive HVAC Steps" column below. Note: After installation of HVAC units and/or ducts, the Installation

48

Empirical Methodologies for Improving HVAC Efficiency  

NLE Websites -- All DOE Office Websites (Extended Search)

Empirical Methodologies for Improving HVAC Efficiency Empirical Methodologies for Improving HVAC Efficiency Speaker(s): Anil Aswani Date: September 21, 2012 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Michael Wetter This talk describes the use of empirical methodologies that we have developed for the purpose of improving heating, ventilation, and air-conditioning (HVAC) efficiency through better control algorithms and configuration. We show that semiparametric regression can both identify simplified models of thermal HVAC dynamics while also estimating time-varying heating loads using only real-time temperature measurements from thermostats. These models can be used with our learning-based model predictive control (LBMPC) method in order to improve the energy-efficiency of HVAC. Experiments on testbeds with different types of HVAC show the

49

HVAC Technician | Princeton Plasma Physics Lab  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC Technician HVAC Technician Department: Facilities Supervisor(s): Tom Ward Staff: L&S 07 Requisition Number: 1300884 Under the supervision of the General Lead Technician and Lead HVAC Technician, the incumbent will be responsible for the installation, preventative maintenance, troubleshooting and repair of various HVAC and refrigeration equipment; local HVAC control systems and ancillary support equipment; and will work with other groups within the Division and throughout the Laboratory to ensure long-term, safe and efficient operation of HVAC and refrigeration systems. All tasks must be completed in a timely, cost efficient manner, support on-going sustainability initiatives and energy efficiency programs at the Laboratory. The incumbent is expected to utilize thorough theoretical knowledge and techniques to accomplish

50

HVAC Commissioning - A Status Report in Taiwan  

E-Print Network (OSTI)

HVAC HVAC CommisioningCommisioning ?? A Status Report in TaiwanA Status Report in Taiwan Dr. K.H. YangDr. K.H. Yang Fellow ASHRAEFellow ASHRAEProfessor, National Sun Professor, National Sun Yat... ,decided to conduct an overall renovation program for the HVAC systems of existing governmental buildings where it is mandatory to adapt BEMS and conducting system commissioning .?This program not only constructs an important step in responding...

Yang, K. H.

2006-01-01T23:59:59.000Z

51

Measuring Advances in HVAC Distribution System Design  

E-Print Network (OSTI)

Advances in HV AC Distribution System Design Ellen FranconiAdvances in HVAC Distribution System Design Ellen Franconisavings result from distribution system design improvements,

Franconi, E.

2011-01-01T23:59:59.000Z

52

Modeling and Identification for HVAC Systems.  

E-Print Network (OSTI)

?? Heating, Ventilation and Air Conditioning (HVAC) systems consist of all the equipment that control the conditions and distribution of indoor air. Indoor air must… (more)

Scotton, Francesco

2012-01-01T23:59:59.000Z

53

HVAC, Water Heating, and Appliances | Department of Energy  

Energy Savers (EERE)

HVAC, Water Heating, and Appliances HVAC, Water Heating, and Appliances How a Small Business is Transforming the Cold Climate Heating Market How a Small Business is Transforming...

54

Energy Department Releases Roadmaps on HVAC Technologies, Water...  

Energy Savers (EERE)

Energy Department Releases Roadmaps on HVAC Technologies, Water Heating, Appliances, and Low-GWP Refrigerants Energy Department Releases Roadmaps on HVAC Technologies, Water...

55

NETL Sorbents Licensed to Help Lower Power Draw of HVAC  

NLE Websites -- All DOE Office Websites (Extended Search)

the energy efficiency of commercial HVAC (heating, ventilation, and air conditioning) systems. HVAC is one of the largest draws of electric power in the United States. In many...

56

DOE Convening Report on Certification of Commercial HVAC and...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Convening Report on Certification of Commercial HVAC and CRE Products DOE Convening Report on Certification of Commercial HVAC and CRE Products This document is the convening...

57

Project examples Install new HVAC, electrical, fire protection,  

E-Print Network (OSTI)

Project examples Install new HVAC, electrical, fire protection, and plumbing systems in Mechanical. · Totransformthisspaceandincreaseaccessibility, anelevatorisrequired.Currently,Blakelydoesnot haveone. Replace HVAC and electrical system

Blanchette, Robert A.

58

Solid State Vehicular Generators and HVAC Development | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Solid State Vehicular Generators and HVAC Development Solid State Vehicular Generators and HVAC Development 2009 DOE Hydrogen Program and Vehicle Technologies Program Annual Merit...

59

Chapter 5: Lighting, HVAC, and Plumbing | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

5: Lighting, HVAC, and Plumbing Chapter 5: Lighting, HVAC, and Plumbing Chapter 5 of the LANL Sustainable Design Guide with guidelines for developing sustainable, healthy,...

60

System-Level Monitoring and Diagnosis of Building HVAC System.  

E-Print Network (OSTI)

??Heating, ventilation, and air conditioning (HVAC) is an indoor environmental technology that is extensively instrumented for large-scale buildings. Among all subsystems of buildings, the HVAC… (more)

Wu, Siyu

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hvac zone summary" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Integration of HVAC System Design with Simplified Duct Distribution...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Integration of HVAC System Design with Simplified Duct Distribution - Building America Top Innovation Integration of HVAC System Design with Simplified Duct Distribution - Building...

62

Utveckling av provmetodik för HVAC på lastbil; Development of test methodology for climatic testing of truck HVAC on trucks.  

E-Print Network (OSTI)

?? I detta examensarbetet undersöks hur provningen av HVAC på lastbilar skall utföras i klimatvindtunneln CD7 som Scania färdigställer till år 2013. HVAC omfattar kupéuppvärmning,… (more)

Jonsson, Björn-Emil

2011-01-01T23:59:59.000Z

63

Optimization Control Strategies for HVAC Terminal Boxes  

E-Print Network (OSTI)

The HVAC terminal boxes are one of the major building HVAC components. They directly impact the building room comfort conditions and the energy costs. How to operate the box in a highly energy efficient way and maintain the room comfort level...

Zhu, Y.; Batten, T.; Noboa, H.; Claridge, D. E.; Turner, W. D.; Liu, M.; Zhou, J.; Cameron, C.; Keeble, D.; Hirchak, R.

2000-01-01T23:59:59.000Z

64

Summary of Vadose -- Zone Conceptual Models for Flow and Contaminant Transport and 1999 - 2003 Progress on Resolving Deficiencies in Understanding the Vadose Zone at the INEEL  

SciTech Connect

The thick vadose zone that underlies the Idaho National Engineering and Environmental Laboratory has been recognized both as an avenue through which contaminants disposed at or near the ground surface can migrate to groundwater in the underlying Eastern Snake River Plain aquifer, and as a barrier to the movement of contaminants into the aquifer. Flow and contaminant transport in the vadose zone at the INEEL is complicated by the highly heterogeneous nature of the geologic framework and by the variations in the behavior of different contaminants in the subsurface. The state of knowledge concerning flow and contaminant transport in the vadose zone at and near the INEEL IN 1999 was summarized in Deficiencies in Vadose Zone Understanding at the Idaho National Engineering and Environmental Laboratory (Wood et al., 2000). These authors identified deficiencies in knowledge of flow and contaminant transport processes in the vadose zone, and provided recommendations for additional work that should be conducted to address these deficiencies. In the period since (Wood et al., 2000) was prepared, research has been published that, to some degree, address these deficiencies. This document provides a bibliography of reports, journal articles, and conference proceedings published 1999 through mid-2003 that are relevant to the vadose zone at or near the INEEL and provides a brief description of each work. Publications that address specific deficiencies or recommendations are identified, and pertinent information from selected publications is presented.

Robert C. Starr; Dana L. Dettmers; Brennon R. Orr; Thomas R. Wood

2003-12-01T23:59:59.000Z

65

Commercial Building HVAC: How it Affects People  

NLE Websites -- All DOE Office Websites (Extended Search)

Commercial Building HVAC: How it Affects People Commercial Building HVAC: How it Affects People Speaker(s): William Fisk Date: November 13, 2000 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: David Faulkner Commercial building heating, ventilating, and air conditioning (HVAC) systems are designed primarily to maintain a reasonable level of thermal comfort while limiting first costs and energy consumption. However, research conducted predominately within the last decade suggests that commercial building HVAC significantly influences human outcomes other than thermal comfort, including the health, satisfaction, and work performance of the building's occupants. This presentation will review the relationships of these outcomes with HVAC system type, filtration system efficiency, indoor air temperature, and outside air ventilation rate.

66

2013 Energy Code Changes That Effect the HVAC  

E-Print Network (OSTI)

2013 Energy Code Changes That Effect the HVAC Industry Tav Commins Mechanical Engineer California Energy Commission #12;HVAC Mandatory Measures For All Newly Installed Residential HVAC Systems (New Watt Draw at .58 W/CFM, or (return duct and filter sizing) MERV 6 Filter #12;Residential HVAC Measures

California at Davis, University of

67

CALIFORNIA ENERGY Large HVAC Field and Baseline Data  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Large HVAC Field and Baseline Data Field Data Collection: Site Survey of the Integrated Design of Large Commercial HVAC Systems research project. The reports are a result of funding Design of Large Commercial HVAC Systems Integrated Design of Small Commercial HVAC Systems Integrated

68

Cooling and Dehumidification HVAC Technology for 1990s  

E-Print Network (OSTI)

Desiccant Cooling and Dehumidification HVAC Technology for 1990s HVAC: Heating, Ventilation Research Trusts SERI #12;Challenges Facing HVAC Industry in 1990's * Reduction of CFCs * Indoor air quality to solve the problems of the HVAC industry faced in1990's for space conditioning. SERI #12;l- = m mN a- mg

Oak Ridge National Laboratory

69

Residential HVAC Indoor Air Quality(ASHRAE 62.2)  

E-Print Network (OSTI)

Residential HVAC && Indoor Air Quality(ASHRAE 62.2) Tav Commins #12;Contact Information · Energy construction, Additions /Alterations · Nonresidential and Residential #12;Residential HVAC && Indoor Air Quality(ASHRAE 62.2) ·HVAC EfficiencyHVAC Efficiency ·Quality Installation (HERS Measures) S li b HERS R t

70

Salsbury and Diamond: Automated Testing of HVAC Systems for Commissioning -1 -Automated Testing of HVAC Systems for Commissioning  

E-Print Network (OSTI)

and Diamond: Automated Testing of HVAC Systems for Commissioning - 1 - Automated Testing of HVAC Systems This paper describes an approach to the automation of the commissioning of HVAC systems. The approach of many HVAC systems is limited more by poor installation, commissioning, and maintenance than by poor

71

Investigation of IAQ-Relevant Surface Chemistry and Emissions on HVAC Filter Materials  

E-Print Network (OSTI)

VOCs emitted by reactions of HVAC filters with ozone usingand Emissions on HVAC Filter Materials Hugo Destaillats andChemistry and Emissions on HVAC Filter Materials Authors:

Destaillats, Hugo

2010-01-01T23:59:59.000Z

72

Bus HVAC energy consumption test method based on HVAC unit behavior  

Science Journals Connector (OSTI)

This paper presents a test method for determination of energy consumption of bus HVAC unit. The energy consumption corresponds to a bus engine fuel consumption increase during the HVAC unit operation period. The HVAC unit energy consumption is determined from the unit input power, which is measured under several levels of bus engine speeds and at different levels of testing heat load in the laboratory environment. Since the bus engine fuel consumption is incrementally induced by powering an HVAC unit, the results are subsequently recalculated to the unit fuel consumption under the defined road cycles in terms of standardized diesel engine. The method is likewise applicable either for classic or electric HVAC units with a main consumer (compressor or high voltage alternator) mechanically driven directly from the bus engine and also for electric HVAC units supplied from an alternative electric energy source in case of hybrid or fully electric buses.

M. Hegar; M. Kolda; M. Kopecka; V. Rajtmajer; A. Ryska

2013-01-01T23:59:59.000Z

73

Utveckling av provmetodik för HVAC på lastbil; Development of test methodology for truck HVAC.  

E-Print Network (OSTI)

?? The issue about how Scania shall perform HVAC tests in the climatic wind tunnel CD7, which Scania is about to complete by year 2013,… (more)

Tedenäs, Jimmy

2011-01-01T23:59:59.000Z

74

BS-8: HVAC Modeling and Simulation  

NLE Websites -- All DOE Office Websites (Extended Search)

BS-8: HVAC Modeling and Simulation BS-8: HVAC Modeling and Simulation Speaker(s): Darko Sucic Date: December 5, 2001 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Satkartar K. Kinney Industry Foundation Classes (IFC), an object data model of buildings, are being developed by the International Alliance for Interoperability (IAI) to support data sharing and exchange in the building and construction industry. The IAI, founded in 1995, has published four releases of IFC so far. Several prototype implementations by leading software companies show that commercial IFC software is beginning to meet end user expectations of interoperability in the industry. BS-8 is an LBNL project that started last summer. It is developing the IFC HVAC extension schemata that will extend the IFC object data model and support the exchange of HVAC information

75

HVAC Equipment Rebate Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC Equipment Rebate Program HVAC Equipment Rebate Program HVAC Equipment Rebate Program < Back Eligibility Agricultural Commercial Industrial Installer/Contractor Institutional Multi-Family Residential Nonprofit Schools Savings Category Heating & Cooling Commercial Heating & Cooling Heating Cooling Heat Pumps Maximum Rebate Rebates of greater than $5,000 require pre-approval Program Info Funding Source Efficiency Vermont Public Benefit Fund Expiration Date 06/30/2013 State Vermont Program Type State Rebate Program Rebate Amount Varies depending on technology and efficiency Provider Efficiency Vermont NOTE: Rebate reservations are required for all boiler and furnace projects. Efficiency Vermont offers rebates for commercial installations of high-efficiency HVAC equipment and controls. For businesses and purchases

76

Recovery Act-Funded HVAC projects  

Energy.gov (U.S. Department of Energy (DOE))

The U.S. Department of Energy was allocated funding from the American Recovery and Reinvestment Act to conduct research into heating, ventilation, and air conditioning (HVAC) technologies and...

77

Interdisciplinary Innovation and Vision in the HVAC  

E-Print Network (OSTI)

potentials for optimizing costs can be found in the HVAC systems when calculated over the total Life-Cycle-Cost (LCC) of a building incorporating planning through to facility management. This requires an accurate plan specifying an efficient technical...

Hecker, T.

2008-01-01T23:59:59.000Z

78

HVAC Energy Recovery Design and Economic Evaluation  

E-Print Network (OSTI)

ENRECO has prepared this paper on HVAC energy recovery to provide the engineer with an overview of the design engineering as well as the economic analysis considerations necessary to evaluate the potential benefits of energy recovery....

Kinnier, R. J.

1979-01-01T23:59:59.000Z

79

A PDI for your HVAC System  

Energy.gov (U.S. Department of Energy (DOE))

This presentation was given at the Summer 2012 DOE Building America meeting on July 25, 2012, and addressed the question "HVAC proper installation energy savings: over-promising or under-deliverying?"

80

Modeling and optimization of building HVAC systems.  

E-Print Network (OSTI)

??This thesis presents the development of hybrid modeling methodologies for HVAC component static/steady-state models and dynamic/transient models, and the development and implementation of a model-based… (more)

Jin, Guang Yu.

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hvac zone summary" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Non-Vapor Compression HVAC Technologies Report  

Energy.gov (U.S. Department of Energy (DOE))

While vapor-compression technologies have served heating, ventilation, and air-conditioning (HVAC) needs very effectively, and have been the dominant HVAC technology for close to 100 years, the conventional refrigerants used in vapor-compression equipment contribute to global climate change when released to the atmosphere. The Building Technologies Office is evaluating low-global warming potential (GWP) alternatives to vapor-compression technologies.

82

Building Technologies Office: HVAC Optimized Heat Exchangers Research  

NLE Websites -- All DOE Office Websites (Extended Search)

Optimized Heat Optimized Heat Exchangers Research Project to someone by E-mail Share Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on Facebook Tweet about Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on Twitter Bookmark Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on Google Bookmark Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on Delicious Rank Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on Digg Find More places to share Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on AddThis.com... About Take Action to Save Energy Partner with DOE Activities Appliances Research Building Envelope Research

83

Comparative guide to emerging diagnostic tools for large commercial HVAC systems  

SciTech Connect

This guide compares emerging diagnostic software tools that aid detection and diagnosis of operational problems for large HVAC systems. We have evaluated six tools for use with energy management control system (EMCS) or other monitoring data. The diagnostic tools summarize relevant performance metrics, display plots for manual analysis, and perform automated diagnostic procedures. Our comparative analysis presents nine summary tables with supporting explanatory text and includes sample diagnostic screens for each tool.

Friedman, Hannah; Piette, Mary Ann

2001-05-01T23:59:59.000Z

84

Comparisons of HVAC Simulations between EnergyPlus and DOE-2.2 for Data Centers  

SciTech Connect

This paper compares HVAC simulations between EnergyPlus and DOE-2.2 for data centers. The HVAC systems studied in the paper are packaged direct expansion air-cooled single zone systems with and without air economizer. Four climate zones are chosen for the study - San Francisco, Miami, Chicago, and Phoenix. EnergyPlus version 2.1 and DOE-2.2 version 45 are used in the annual energy simulations. The annual cooling electric consumption calculated by EnergyPlus and DOE-2.2 are reasonablely matched within a range of -0.4percent to 8.6percent. The paper also discusses sources of differences beween EnergyPlus and DOE-2.2 runs including cooling coil algorithm, performance curves, and important energy model inputs.

Hong, Tianzhen; Sartor, Dale; Mathew, Paul; Yazdanian, Mehry

2008-08-13T23:59:59.000Z

85

Building Technologies Office: Recovery Act-Funded HVAC Research Projects  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC Research Projects to someone by E-mail HVAC Research Projects to someone by E-mail Share Building Technologies Office: Recovery Act-Funded HVAC Research Projects on Facebook Tweet about Building Technologies Office: Recovery Act-Funded HVAC Research Projects on Twitter Bookmark Building Technologies Office: Recovery Act-Funded HVAC Research Projects on Google Bookmark Building Technologies Office: Recovery Act-Funded HVAC Research Projects on Delicious Rank Building Technologies Office: Recovery Act-Funded HVAC Research Projects on Digg Find More places to share Building Technologies Office: Recovery Act-Funded HVAC Research Projects on AddThis.com... About Take Action to Save Energy Partner with DOE Activities Appliances Research Building Envelope Research Windows, Skylights, & Doors Research Space Heating & Cooling Research

86

Building Technologies Office: HVAC and Water Heater Field Tests Research  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC and Water Heater HVAC and Water Heater Field Tests Research Project to someone by E-mail Share Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Facebook Tweet about Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Twitter Bookmark Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Google Bookmark Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Delicious Rank Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Digg Find More places to share Building Technologies Office: HVAC and Water Heater Field Tests Research Project on AddThis.com... About Take Action to Save Energy Partner with DOE Activities Appliances Research

87

Theoretical Minimum Energy Use of a Building HVAC System  

E-Print Network (OSTI)

This paper investigates the theoretical minimum energy use required by the HVAC system in a particular code compliant office building. This limit might be viewed as the "Carnot Efficiency" for HVAC system. It assumes that all ventilation and air...

Tanskyi, O.

2011-01-01T23:59:59.000Z

88

EECBG Success Story: HVAC Upgrade Saving Money, Protecting History...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC Upgrade Saving Money, Protecting History EECBG Success Story: HVAC Upgrade Saving Money, Protecting History November 2, 2010 - 5:37pm Addthis A new heating and cooling system...

89

System Optimization - The Global Approach to HVAC Control  

E-Print Network (OSTI)

System Optimization is a new approach to HVAC control as implemented by Energy Management Control Systems. System Optimization is defined as electronic building control strategies which treat a building's HVAC components as a complete energy...

Thielman, D. E.

1984-01-01T23:59:59.000Z

90

Practical Approach in Design of HVAC Systems Utilizing Geothermal Energy  

Science Journals Connector (OSTI)

Geothermal is the Earth’s thermal energy. In recent years geothermal energy has been utilized for generation of electricity, heating and air conditioning (HVAC). Geothermal HVAC systems are cost effective, energy

M. Fathizadeh; D. Seims

2014-01-01T23:59:59.000Z

91

Energy Master Plans for Sustainable, High Performance HVAC and Associated Systems for Hot and Humid Climates  

E-Print Network (OSTI)

; Equal pressure ducting systems; Modular heating and cooling generation, small zone control. 4.Complexity: If you cannot understand the system without explanation, it is too complex. If you need to read a sequence of operation more than once... by over 75%. It is the HVAC system selection and in particular the distribution systems that require to be carefully selected and designed to achieve long-term minimum electrical use. Electrical refrigeration uses only 25% of the electricity...

Maisey, G. E.; Milestone, B.

2004-01-01T23:59:59.000Z

92

Implementation and main results Ecient Management of HVAC Systems  

E-Print Network (OSTI)

water to remove heat from the air in the building. In HVAC system equipped with chillers, the electrical #12;Motivation Implementation and main results HVAC Systems Multiple-chiller systems Heating, Ventilation and Air-Conditioning System Heating, Ventilation and Air Conditioning Systems (HVAC) represents

Schenato, Luca

93

Atmospheric Environment 41 (2007) 31513160 Ozone removal by HVAC filters  

E-Print Network (OSTI)

Atmospheric Environment 41 (2007) 3151­3160 Ozone removal by HVAC filters P. Zhao, J.A. Siegel�, R May 2006; accepted 14 June 2006 Abstract Residential and commercial HVAC filters that have been loaded of the relative importance of HVAC filters as a removal mechanism for ozone in residential and commercial

Siegel, Jeffrey

94

MATERIALS AND INFORMATION FLOWS FOR HVAC DUCTWORK FABRICATION AND SITE  

E-Print Network (OSTI)

MATERIALS AND INFORMATION FLOWS FOR HVAC DUCTWORK FABRICATION AND SITE INSTALLATION Matt Holzemer,1, and air-conditioning (HVAC) systems requires a set of complex activities and handoffs between multiple architecture-, engineering-, and construction practitioners. This paper highlights one part of the HVAC

Tommelein, Iris D.

95

ThermoSense: Occupancy Thermal Based Sensing for HVAC Control  

E-Print Network (OSTI)

ThermoSense: Occupancy Thermal Based Sensing for HVAC Control Alex Beltran Elect. Eng. & Comp Occupancy Sensing, Thermal Sensing, HVAC Control 1. INTRODUCTION From 1980 to 2010, energy in the United, November 13-14 2013, Rome, Italy. Copyright 2013 ACM 978-1-4503-2431-1/13/11 ...$15.00. (HVAC) consumed 42

Cerpa, Alberto E.

96

SMUD's HVAC Programs Ravi Patel-Program Planning  

E-Print Network (OSTI)

1 SMUD's HVAC Programs 5-7-13 Ravi Patel- Program Planning Bruce Baccei- R&D #12;SMUD's Residential contractors trained and BPI certified ­ Majority were pushing only HVAC; now driving the HPP · Program encourages more HVAC replacements to occur through HPP ­ Move away from stand alone programs ­ Start

California at Davis, University of

97

Lessons Learned During HVAC Installation Dept. of Computer Science  

E-Print Network (OSTI)

Lessons Learned During HVAC Installation Ian Watson AI-CBR Dept. of Computer Science University of HVAC equipment. It has been developed as an adjunct to an existing system that uses case-based reasoning to reuse previous HVAC installation specifications and designs. The system described lets

Watson, Ian

98

An update on acoustics designs for HVAC (Engineering) K. Marriott  

E-Print Network (OSTI)

An update on acoustics designs for HVAC (Engineering) K. Marriott IOA, 29a Ashburton Road, Croydon and Air Conditioning (HVAC) engineer is to engineer ways for keeping these factors under control the HVAC engineer's environmental requirements while minimizing noise generated in the process considering

Paris-Sud XI, Université de

99

Utilizing Passive Ventilation to Complement HVAC Systems in Enclosed Buildings  

E-Print Network (OSTI)

Utilizing Passive Ventilation to Complement HVAC Systems in Enclosed Buildings Tom Rogg REU Student to assist HVAC has the potential to significantly reduce life cycle cost and energy consumption and electrical system that will tie thermostats to controlled valves in the actual HVAC system. Based on results

Mountziaris, T. J.

100

Modeling and simulation of HVAC Results in EnergyPlus  

E-Print Network (OSTI)

LBNL-5564E Modeling and simulation of HVAC Results in EnergyPlus Mangesh Basarkar, Xiufeng Pang;MODELING AND SIMULATION OF HVAC FAULTS IN ENERGYPLUS Mangesh Basarkar, Xiufeng Pang, Liping Wang, Philip not capture the significant impact of installation, operational and degradation HVAC system faults on actual

Note: This page contains sample records for the topic "hvac zone summary" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Monitoring-based HVAC Commissioning of an Existing Office  

E-Print Network (OSTI)

LBNL-5940E Monitoring-based HVAC Commissioning of an Existing Office Building for Energy Efficiency thereof or The Regents of the University of California. #12;1 Monitoring-based HVAC Commissioning@lbl.gov, Tel: 1-510-486-4921 Abstract The performance of Heating, Ventilation and Air Conditioning (HVAC

102

Handover Performance of HVAC Duct Based Indoor Wireless Networks  

E-Print Network (OSTI)

Handover Performance of HVAC Duct Based Indoor Wireless Networks A. E. Xhafa, P. Sonthikorn, and O in indoor wireless net- works (IWN) that use heating, ventilation, and air conditioning (HVAC) ducts.e., new call blocking and handover dropping probabilities, of an IWN that uses HVAC ducts are up to 6

Stancil, Daniel D.

103

Implementation of a Scenario-based MPC for HVAC Systems  

E-Print Network (OSTI)

Implementation of a Scenario-based MPC for HVAC Systems: an Experimental Case Study Alessandra, Ventilation and Air Conditioning (HVAC) systems play a fundamental role in maintaining acceptable thermal energy savings potential. Developing effective MPC-based control strategies for HVAC systems

Johansson, Karl Henrik

104

Continued on next page A letter explaining the 2005 HVAC  

E-Print Network (OSTI)

Continued on next page A letter explaining the 2005 HVAC Change-out to consumers is available this bulletin, or downloaded from the 2005 HVAC Change out Information website at: www.energy.ca.gov/title24 duct sealing requirements for HVAC change-outs in existing homes become effective October 1, 2005

105

Deposition of Biological Aerosols on HVAC Heat Exchangers  

E-Print Network (OSTI)

LBNL-47669 Deposition of Biological Aerosols on HVAC Heat Exchangers Jeffrey Siegel and Iain Walker of Biological Aerosols on HVAC Heat Exchangers Jeffrey A. Siegel Iain S. Walker, Ph.D. ASHRAE Student Member that are found in commercial and residential HVAC systems of 1 - 6 m/s (200 - 1200 ft/min), particle diameters

106

Tematiche di ricerca Controllo di sistemi HVAC&R  

E-Print Network (OSTI)

Tematiche di ricerca Controllo di sistemi HVAC&R Controllo di processo per l'industria dei;Tematiche di ricerca Controllo di sistemi HVAC&R Controllo di processo per l'industria dei semiconduttori controllo di sistemi HVAC&R 2 Controllo di processo per l'industria dei semiconduttori 3 Problemi di

Schenato, Luca

107

Long Range Passive UHF RFID System Using HVAC Ducts  

E-Print Network (OSTI)

INVITED P A P E R Long Range Passive UHF RFID System Using HVAC Ducts To provide a potential communications channel, HVAC ducts can function as electromagnetic waveguides; a 30-m read range has been-conditioning (HVAC) ducts as a potential communication channel between passive ultrahigh-frequency (UHF) radio

Hochberg, Michael

108

Chapter 5: Lighting, HVAC, and Plumbing  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

: Lighting, : Lighting, HVAC, and Plumbing High-Performance Engineering Design Lighting System Design Mechanical System Design Central Plant Systems Plumbing and Water Use Building Control Systems Electrical Power Systems Metering LANL | Chapter 5 High-Performance Engineering Design Lighting, HVAC, and Plumbing By now, the building envelope serves multiple roles. It protects the occupants from changing weather condi- tions and it plays a key part in meeting the occupants' comfort needs. The heating, ventilating, air-conditioning, and lighting (HVAC&L) systems complement the archi- tectural design, govern the building's operation and maintenance costs, and shape the building's long-term environmental impact. The architectural design maximizes the potential for a high-performance building, but it is the

109

A PDI for your HVAC System  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

8/3/2012 Technical Approach Develop a PDI for HVAC PDI focus is on Inspecting Installation - a $10 Chinese sweatshop t-shirt gets a QA/QC sticker, why not a $10k HVAC system? Develop & require diagnostics that confirm good installations: - Air flow, duct leakage, refrigerant charge, delivered temperatures, system pressures, filter requirements, fan power, noise - On board diagnostics (OBD) for flow, pressures, fan power, charge Make it a warranty requirement, code requirement, permit requirement, etc. Recommended Guidance Develop the PDI checklist and label (include target and system test results) - External Tests: duct leaks - Internal Tests: OBD for system pressures, air flow, charge, fan power - Labels: Certify tight equipment

110

Wavelet based artificial neural network applied for energy efficiency enhancement of decoupled HVAC system  

Science Journals Connector (OSTI)

Control methodologies could lower energy demand and consumption of heating, ventilating and air conditioning (HVAC) systems and, simultaneously, achieve better comfort conditions. However, the application of classical controllers is unsatisfactory as HVAC systems are non-linear and the control variables such as temperature and relative humidity (RH) inside the thermal zone are coupled. The objective of this study is to develop and simulate a wavelet-based artificial neural network (WNN) for self tuning of a proportional-derivative (PD) controller for a decoupled bi-linear HVAC system with variable air volume and variable water flow responsible for controlling temperature and RH of a thermal zone, where thermal comfort and energy consumption of the system are evaluated. To achieve the objective, a WNN is used in series with an infinite impulse response (IIR) filter for faster and more accurate identification of system dynamics, as needed for on-line use and off-line batch mode training. The WNN-IIR algorithm is used for self-tuning of two PD controllers for temperature and RH. The simulation results show that the WNN-IIR controller performance is superior, as compared with classical PD controller. The enhancement in efficiency of the HVAC system is accomplished due to substantially lower consumption of energy during the transient operation, when the gain coefficients of PD controllers are tuned in an adaptive manner, as the steady state setpoints for temperature and RH are better reached in a shorter period of time. The multi-zone analyses are suggested for future work.

G. Jahedi; M.M. Ardehali

2012-01-01T23:59:59.000Z

111

Research & Development Roadmap: Emerging HVAC Technologies  

Energy.gov (U.S. Department of Energy (DOE))

The Research and Development (R&D) Roadmap for Emerging Heating, Ventilation, and Air-Conditioning (HVAC) Technologies provides recommendations to the Building Technologies Office (BTO) on R&D activities to pursue that will aid in achieving BTO’s energy savings goals.

112

University of North Carolina at Charlotte Design and Construction Manual Section 2, Division 23 HVAC  

E-Print Network (OSTI)

­ HVAC SECTION 2 DIVISION 23 HVAC #12;University of North Carolina at Charlotte Design and Construction Manual Section 2, Division 23 ­ HVAC DIVISION 23 - HVAC Note: This is a guide for Designers only 23 0510 - MECHANICAL GENERAL - HVAC PART 1 - GENERAL 1.1 MECHANICAL DESIGNER: A. Design

Xie,Jiang (Linda)

113

Laboratory measurement of secondary pollutant yields from ozone reaction with HVAC filters.  

E-Print Network (OSTI)

Ozone Reaction with HVAC Filters Hugo Destaillats, WenhaoOzone Reaction with HVAC Filters Hugo Destaillats 1,3,* ,Ozone Reaction with HVAC Filters Hugo Destaillats 1,3,* ,

Destaillats, Hugo

2012-01-01T23:59:59.000Z

114

HVAC Efficiency Controls Could Mean Significant Savings | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC Efficiency Controls Could Mean Significant Savings HVAC Efficiency Controls Could Mean Significant Savings HVAC Efficiency Controls Could Mean Significant Savings April 27, 2012 - 11:58am Addthis HVAC Efficiency Controls Could Mean Significant Savings April Saylor April Saylor Former Digital Outreach Strategist, Office of Public Affairs What does this mean for me? Commercial building owners could save an average 38% on their heating & cooling bills just by installing a few new controls onto their HVAC systems. According to a new report from Pacific Northwest National Lab, commercial building owners could save an average 38 percent on their heating and cooling bills just by installing a few new controls onto their HVAC systems. These findings mean significant potential savings for building owners who use commercial rooftop systems - but there's just one problem: the

115

Applications of HVAC System Utilizing Building Thermal Mass in Japan  

NLE Websites -- All DOE Office Websites (Extended Search)

Applications of HVAC System Utilizing Building Thermal Mass in Japan Applications of HVAC System Utilizing Building Thermal Mass in Japan Speaker(s): Katsuhiro Miura Date: January 27, 2012 - 10:00am Location: 90-3122 Seminar Host/Point of Contact: Michael Wetter Buildings have a large thermal capacity and it affects much on building thermal load for the HVAC system. The thermal mass can be utilized also to control the thermal load by storing thermal energy before HVAC operation. There are two ways to store thermal energy. One is by operating the HVAC system and the other is by natural ventilation, mainly at night. The latter could be combined with daily HVAC operation as a hybrid ventilation. Thermal mass storage is useful to decrease the hourly peak load and the daily thermal load and can be used for both cooling and heating purpose.

116

Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger  

NLE Websites -- All DOE Office Websites (Extended Search)

Radial Air Bearing Radial Air Bearing Heat Exchanger Research Project to someone by E-mail Share Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Facebook Tweet about Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Twitter Bookmark Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Google Bookmark Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Delicious Rank Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Digg Find More places to share Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on AddThis.com... About Take Action to Save Energy Partner with DOE

117

Pitfalls in Building and HVAC Systems  

E-Print Network (OSTI)

the summer savings. ? Consider all forms of savings, not just en ergy. Opportunities are often missed be cause only energy savings are consideted. For example, the installation of extetior wall insulation or aluminum thermopane win dows result in a...PITFALLS IN BUILDING AND HVAC SYSTEMS B. N. Gidwani, P.E. Roy F. Weston, Inc. West Chester, Pennsylvania ABSTRACT The purpose of an energy audit is to identify and analyze areas of energy consumption and to pro pose methods of conservation...

Gidwani, B. N.

118

Pedernales Electric Cooperative - HVAC Rebate Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Pedernales Electric Cooperative - HVAC Rebate Program Pedernales Electric Cooperative - HVAC Rebate Program Pedernales Electric Cooperative - HVAC Rebate Program < Back Eligibility Commercial Residential Commercial Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Program Info State Texas Program Type Utility Rebate Program Utility Rebate Program Rebate Amount Central AC with Gas Furnace: $300 - $400/unit Heat Pump: $400 - $500/unit Dual-Fuel Heat Pump: $400 - $500/unit Geothermal Heat Pump: $1,000/unit Water-Source Heat Pump: $1,000/unit Provider Pedernales Electric Cooperative Pedernales Electric Cooperative offers equipment rebates to members who install energy efficient HVAC equipment. Eligible equipment includes:

119

Fabrication of A Quantum Well Based System for Truck HVAC  

Energy.gov (U.S. Department of Energy (DOE))

Discusses performance differences between conventional modules and quantum well modules and details a conventional HZ-14 device, using bulk bismuth-telluride advantageous for truck HVAC applications.

120

Fault Detection and Diagnosis in Building HVAC Systems.  

E-Print Network (OSTI)

??Building HVAC systems account for more than 30% of annual energy consumption in United States. However, it has become apparent that only in a small… (more)

Najafi, Massieh

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hvac zone summary" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

The impact of filter loading on residential hvac performance.  

E-Print Network (OSTI)

??Buildings are the primary user of energy in the USA. Within homes, the heating, ventilation, and air condition (HVAC) system is the largest energy consumer.… (more)

Kruger, Abraham J.

2013-01-01T23:59:59.000Z

122

Comparison of Building Energy Modeling Programs: HVAC Systems  

E-Print Network (OSTI)

or FAU with no control), supply water temperature, pressureunder the same control The supply air temperature and supplyHVAC control strategies of supply air temperature, supply

Zhou, Xin

2014-01-01T23:59:59.000Z

123

Improving the Efficiency of Light-Duty Vehicle HVAC Systems using...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Light-Duty Vehicle HVAC Systems using Zonal Thermoelectric Devices and Comfort Modeling Improving the Efficiency of Light-Duty Vehicle HVAC Systems using Zonal Thermoelectric...

124

A Scenario-based Predictive Control Approach to Building HVAC Management Systems  

E-Print Network (OSTI)

A Scenario-based Predictive Control Approach to Building HVAC Management Systems Alessandra Parisio and Air Conditioning (HVAC) systems while minimizing the overall energy use. The strategy uses

Johansson, Karl Henrik

125

SIMULATION AND EXPERIMENTAL VALIDATION OF AIRBORNE AND STRUCTURE-BORNE NOISE TRANSMISSION IN HVAC PLENUMS.  

E-Print Network (OSTI)

??This research demonstrates the usage of numerical acoustics to model sound and vibrational energy propagation in HVAC ducts and plenums. Noise and vibration in HVAC… (more)

Ramalingam, Srinivasan

2012-01-01T23:59:59.000Z

126

Characterization of HVAC operation uncertainty in EnergyPlus AHU modules.  

E-Print Network (OSTI)

??This study addresses 5 uncertainties that exist in the operation of HVAC systems, which will presumably affect the actual energy consumption of the HVAC system… (more)

Sui, Di

2014-01-01T23:59:59.000Z

127

This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)  

E-Print Network (OSTI)

at Oklahoma State University (www.hvac.okstate.edu) The correct citation for the paper is: Xiao, D., J) and may become part of the ASHRAE standard method of test for whole building energy simulation programs (ASHRAE Standard 140). The existing test suite is comprised of tests that use a single building zone

128

Combining HVAC energy conservation measures to achieve energy savings over standard requirements  

Science Journals Connector (OSTI)

Abstract This paper presents the energy savings over the minimum American Society of Heating Refrigeration and Air-Conditioning Engineers (ASHRAE) Standard 90.1-2010 requirements due to the combination of two or three HVAC energy conservation measures using EnergyPlus simulation software. Prototype commercial building models, which satisfy the requirements of ASHRAE Standard 90.1-2010 were used as base-cases. Five prototype commercial buildings, eight HVAC systems, and eight climate zones were considered. Four cases were studied for the combination: energy recovery ventilation (ERV) and demand control ventilation (DCV); ERV and Multiple-zone variable air volume (VAV) System Ventilation Optimization (VentOpt); ERV, DCV and VentOpt; and Single Zone VAV controls, and kitchen transfer air. Of the four cases studied, the integration of ERV and DCV, which was applied to primary school and standalone retail prototype buildings, provided a maximum savings of 1.93% and 8.10% respectively compared to the base-cases.

Teshome Edae Jiru

2014-01-01T23:59:59.000Z

129

Energy efficient HVAC system features thermal storage and heat recovery  

SciTech Connect

This article describes a HVAC system designed to efficiently condition a medical center. The topics of the article include energy efficient design of the HVAC system, incentive rebate program by the local utility, indoor air quality, innovative design features, operations and maintenance, payback and life cycle cost analysis results, and energy consumption.

Bard, E.M. (Bard, Rao + Athanas Consulting Engineering Inc., Boston, MA (United States))

1994-03-01T23:59:59.000Z

130

Occupancy Based Demand Response HVAC Control Strategy Varick L. Erickson  

E-Print Network (OSTI)

Occupancy Based Demand Response HVAC Control Strategy Varick L. Erickson University of California an efficient demand response HVAC control strategy, actual room usage must be considered. Temperature and CO2 are used for simulations but not for predictive demand response strategies. In this paper, we develop

Cerpa, Alberto E.

131

HVAC & Building Management Control System Energy Efficiency Replacements  

SciTech Connect

The project objective was the replacement of an aging, un-repairable HVAC system which has grown inefficient and a huge energy consumer with low energy and efficient HVAC units, and installation of energy efficient building control technologies at City's YMCA Community Center.

Hernandez, Adriana

2012-09-21T23:59:59.000Z

132

Columbia Water and Light - HVAC and Lighting Efficiency Rebates |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Columbia Water and Light - HVAC and Lighting Efficiency Rebates Columbia Water and Light - HVAC and Lighting Efficiency Rebates Columbia Water and Light - HVAC and Lighting Efficiency Rebates < Back Eligibility Commercial Industrial Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Lighting: 50% of invoiced cost up to $22,500 Program Info State Missouri Program Type Utility Rebate Program Rebate Amount HVAC Replacements: $570 - $3,770 Lighting: $300/kW reduction or half of project cost Provider Columbia Water and Light Columbia Water and Light (CWL) offers rebates to its commercial and industrial customers for the purchase of high efficiency HVAC installations and efficient lighting. Incentives for certain measures are based upon the

133

Building Energy Software Tools Directory: HVAC 1 Toolkit  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC 1 Toolkit HVAC 1 Toolkit HVAC 1 Toolkit logo. The Toolkit for Primary HVAC System Energy Calculations is a collection of thirty-eight separate subroutines and corresponding documentation that describes algorithms for predicting the performance of HVAC components. The Toolkit documentation includes thorough descriptions of the component models and solution algorithms, detailed information on the structure of the individual FORTRAN 77 routines, as well as illustrative examples of system simulations with the Toolkit routines. The Toolkit serves two purposes: modules for large-scale simulation and stand-alone component performance prediction. The Toolkit components can also be used to calculate the energy performance of a component with a dedicated driver program to provide the necessary information flow to the Toolkit routines.

134

A Fault Detection and Diagnosis Method for HVAC Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

A Fault Detection and Diagnosis Method for HVAC Systems A Fault Detection and Diagnosis Method for HVAC Systems Speaker(s): Peng Xu Date: December 2, 2002 - 12:00pm Location: Bldg. 90 There is a growing consensus that most buildings do not perform as well as intended and that faults in HVAC systems are widespread in commercial buildings. An automated fault detection and diagnosis tool for HVAC systems is being developed, based on an integrated, life-cycle, approach to commissioning and performance monitoring. The tool uses component-level HVAC equipment models implemented in the SPARK equation-based simulation environment. The models are configured using design information and component manufacturers' data and then fine-tuned to match the actual performance of the equipment by using data measured during functional tests

135

Best practices guide for residential HVAC Retrofits  

SciTech Connect

This best practices guide for residential HVAC system retrofits is aimed at contractors who want guidance on delivering energy efficient, cost effective and innovative products. It has been developed around the idea of having packages of changes to the building HVAC system and building envelope that are climate and house construction dependent. These packages include materials, procedures and equipment and are designed to remove some of the guesswork from a builder, contractor, installer or homeowner decisions about how best to carry out HVAC changes. The packages are not meant to be taken as rigid requirements--instead they are systems engineered guidelines that form the basis for energy efficient retrofits. Similar approaches have been taken previously for new construction to develop extremely energy efficient homes that are comfortable safe and durable, and often cost less than standard construction. This is best epitomized by the Building America program whose partners have built thousands of residences throughout the U.S. using these principles. The differences between retrofitting and new construction tend to limit the changes one can make to a building, so these packages rely on relatively simple and non-intrusive technologies and techniques. The retrofits also focus on changes to a building that will give many years of service to the occupants. Another key aspect of these best practices is that we need to know how a house is working so that we know what parts have the potential for improvement. To do this we have put together a set of diagnostic tools that combine physical measurements and checklists/questionnaires. The measured test results, observations and homeowner answers to questions are used to direct us towards the best retrofits applicable to each individual house. The retrofits will depend on the current condition of the building envelope and HVAC system, the local climate, the construction methods used for the house, and the presence of various energy saving systems (e.g., a Heat Recovery Ventilator) and/or materials. This is just like a doctor referring a patient for blood tests or x-rays before actually performing surgery. This way the doctor can be sure that he does the right thing. To take this analogy further--we can borrow from the medical profession and say that the first thought when retrofitting a house is to do no harm, i.e., do not make changes that could make the house worse to live in.

Walker, Iain S.

2003-08-11T23:59:59.000Z

136

VARIABLE SPEED INTEGRATED INTELLIGENT HVAC BLOWER  

SciTech Connect

This comprehensive topical report discusses the key findings in the development of an advanced blower for HVAC applications. The benefits of rearward inclined blades over that of traditional forward inclined blades is well documented, and several prototype wheels are demonstrated in various housings. A comparison of retrofitted blowers to that of three typical units from the industry is presented. The design and modification of the blower housing is addressed and the impact of size limitations on static efficiency is discussed. The roadmap to rearward-inclined wheel technology insertion is presented and typical static efficiency gains are documented.

Herman Wiegman; Charlie Stephens; Xiaoyue Liu; Ralph Carl; Sunny Zhuang; Paul Szczesny; Kamron Wright

2003-09-23T23:59:59.000Z

137

OBSERVE: Occupancy-Based System for Efficient Reduction of HVAC Energy  

E-Print Network (OSTI)

OBSERVE: Occupancy-Based System for Efficient Reduction of HVAC Energy Varick L. Erickson, Miguel Á & control General Terms Algorithms, Machine Learning, Measurement Keywords Occupancy, HVAC, Ventilation for heating, ventilation, and air-conditioning (HVAC) systems[2]. Studies suggest that 15% to 25% of HVAC

Carreira-Perpiñán, Miguel Á.

138

Duty-Cycling Buildings Aggressively: The Next Frontier in HVAC Control  

E-Print Network (OSTI)

Duty-Cycling Buildings Aggressively: The Next Frontier in HVAC Control Yuvraj Agarwal, Bharathan the dominant energy consumer is the HVAC system. Despite this fact, in most buildings the HVAC system is run sensing to guide the operation of a building HVAC system. We show how we can enable aggressive duty

Simunic, Tajana

139

Evaluation of HVAC filters as a sampling mechanism for indoor microbial communities  

E-Print Network (OSTI)

Evaluation of HVAC filters as a sampling mechanism for indoor microbial communities Federico Noris Fungi Microbial community HVAC filter Settled dust Air a b s t r a c t HVAC filters are in place of bacterial and fungal concentrations and communities in HVAC filter dust and other sampling locations

Siegel, Jeffrey

140

The Impact of Uncertain Physical Parameters on HVAC Demand Response  

SciTech Connect

HVAC units are currently one of the major resources providing demand response (DR) in residential buildings. Models of HVAC with DR function can improve understanding of its impact on power system operations and facilitate the deployment of DR technologies. This paper investigates the importance of various physical parameters and their distributions to the HVAC response to DR signals, which is a key step to the construction of HVAC models for a population of units with insufficient data. These parameters include the size of floors, insulation efficiency, the amount of solid mass in the house, and efficiency of the HVAC units. These parameters are usually assumed to follow Gaussian or Uniform distributions. We study the effect of uncertainty in the chosen parameter distributions on the aggregate HVAC response to DR signals, during transient phase and in steady state. We use a quasi-Monte Carlo sampling method with linear regression and Prony analysis to evaluate sensitivity of DR output to the uncertainty in the distribution parameters. The significance ranking on the uncertainty sources is given for future guidance in the modeling of HVAC demand response.

Sun, Yannan; Elizondo, Marcelo A.; Lu, Shuai; Fuller, Jason C.

2014-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "hvac zone summary" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Index to Evaluate Energy Efficiency of the Building HVAC System  

E-Print Network (OSTI)

1An Index to Evaluate Energy Efficiency of the Entire Building HVAC System Presented by Dr. Claridge Date: 09/15/2014 ESL-IC-14-09-15 Proceedings of the 14th International Conference for Enhanced Building Operations, Beijing, China, September 14..., Beijing, China, September 14-17, 2014 3• Why we need the Energy/Load Ratio 1. Building 2. HVAC Systems 3. Common Index • Building sector consumes 40% of total energy usage in US (Residential buildings – 22%, Commercial building – 19%) • HVAC systems...

Wang, L.; Wang, L.; Claridge,D.

2014-01-01T23:59:59.000Z

142

Heat recovery and the economizer for HVAC systems  

SciTech Connect

This articles examines why a combined heat reclaim/economizer system with priority to heat reclaim operation is most likely to result in the least annual total HVAC energy. PC-based, hour-by-hour simulation programs evaluate annual HVAC energy requirements when using combined operation of heat reclaim and economizer cycle, while giving priority to operation of either one. These simulation programs also enable the design engineer to select the most viable heat reclaim and/or economizer system for any given type of HVAC system serving the building internal load level, building geographical location and other building/system variables.

Anantapantula, V.S. (Emerson Electric Co., St. Louis, MO (United States). Alco Controls Div.); Sauer, H.J. Jr. (Univ. of Missouri, Rolla, MO (United States))

1994-11-01T23:59:59.000Z

143

Unusual HVAC challenges require innovative solutions  

SciTech Connect

There were many reasons behind Motorola`s decision to build the first 225,000 sq ft of a planned one million sq ft manufacturing facility in Chihuahua, Mexico. Among these were the availability of skilled labor in the area, lower construction costs, some export tax advantages, and the close proximity to the US border. The new facility is made up of a variety of functional areas that together create an impressively efficient plant. Phase 1 construction included a large manufacturing floor, shipping and receiving areas, a bulk storage facility, and a large office area with a view of the factory floor. The structure also houses a retail store where Motorola consumer products are sold, a conference and banquet center, a commercial kitchen, and dining facilities for 750. The design cooling load is 750 tons; the heating load is 4.5 million Btuh. The paper discusses the challenging location, the HVAC system, and the future expansion planned.

Jardine, G.M.; Gwin, O.D. [Heery International, Inc., Atlanta, GA (United States)

1998-02-01T23:59:59.000Z

144

Thermal model of solar absorption HVAC systems  

SciTech Connect

This paper presents a thermal model that describes the performance of solar absorption HVAC systems. The model considers the collector array, the building cooling and heating loads, the absorption chiller and the high temperature storage. Heat losses from the storage tank and piping are included in the model. All of the results presented in the paper are for an array of flat plate solar collectors with black chrome (selective surface) absorber plates. The collector efficiency equation is used to calculate the useful heat output from the array. The storage is modeled as a non-stratified tank with polyurethane foam insulation. The system is assumed to operate continuously providing air conditioning during the cooling season, space heating during the winter and hot water throughout the year. The amount of heat required to drive the chiller is determined from the coefficient of performance of the absorption cycle. Results are presented for a typical COP of 0.7. The cooling capacity of the chiller is a function of storage (generator) temperature. The nominal value is 190 F (88 C) and the range of values considered is 180 F (82 C) to 210 F (99 C). Typical building cooling and heating loads are determined as a function of ambient conditions. Performance results are presented for Sacramento, CA and Washington, D.C. The model described in the paper makes use of National Solar Radiation Data Base (NSRDB) data and results are presented for these two locations. The uncertainties in the NSRDB are estimated to be in a range of 6% to 9%. This is a significant improvement over previously available data. The model makes it possible to predict the performance of solar HVAC systems and calculate quantities such as solar fraction, storage temperature, heat losses and parasitic power for every hour of the period for which data are available.

Bergquam, J.B.; Brezner, J.M. [California State Univ., Sacramento, CA (United States). Dept. of Mechanical Engineering; [Bergquam Energy Systems, Sacramento, CA (United States)

1995-11-01T23:59:59.000Z

145

Connexus Energy - Residential Efficient HVAC Rebate Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Connexus Energy - Residential Efficient HVAC Rebate Program Connexus Energy - Residential Efficient HVAC Rebate Program Connexus Energy - Residential Efficient HVAC Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Program Info Expiration Date 12/31/2013 State Minnesota Program Type Utility Rebate Program Rebate Amount Air Source Heat Pumps: $480 - $630 Ductless Heat Pump: $150 Geothermal Heat Pump: $200/ton Provider Connexus Energy Connexus Energy offers rebates for residential customers to improve the energy efficiency of homes. Rebates are available for air source heat pumps, ductless heat pumps and ground-source heat pumps. Equipment must meet all efficiency standards listed on the web site, and must be installed by a certified HVAC contractor. Contact Connexus Energy for other program

146

A Web Based CBR System for HVAC Sales Support  

Science Journals Connector (OSTI)

This paper describes the implementation of a CBR system to support HVAC sales staff operating in remote locations. The ... the world wide web and uses the new standard of XML as a communications protocol between....

Dan Gardingen; Ian Watson

1999-01-01T23:59:59.000Z

147

HVAC Cabinet Air Leakage Test Method- Building America Top Innovation  

Energy.gov (U.S. Department of Energy (DOE))

This 2014 Top Innovation describes Building America research that resulted in the development of an ASHRAE standard and standardized testing method for testing the air leakage of HVAC air handlers and furnace cabinets.

148

A Quasi-Dynamic HVAC and Building Simulation Methodology  

E-Print Network (OSTI)

This thesis introduces a quasi-dynamic building simulation methodology which complements existing building simulators by allowing transient models of HVAC (heating, ventilating and air-conditioning) systems to be created in an analogous way...

Davis, Clinton Paul

2012-07-16T23:59:59.000Z

149

Review of Residential Low-Load HVAC Systems  

SciTech Connect

In support of the U.S. Department of Energy’s (DOE’s) Building America Program, Pacific Northwest National Laboratory (PNNL) conducted an investigation to inventory commercially available HVAC technologies that are being installed in low-load homes. The first step in this investigation was to conduct a review of published literature to identify low-load HVAC technologies available in the United States and abroad, and document the findings of existing case studies that have evaluated the performance of the identified technologies. This report presents the findings of the literature review, identifies gaps in the literature or technical understanding that must be addressed before low-load HVAC technologies can be fully evaluated, and introduces PNNL’s planned research and analysis for this project to address identified gaps and potential future work on residential low-load HVAC systems.

Brown, Scott A.; Thornton, Brian; Widder, Sarah H.

2013-09-01T23:59:59.000Z

150

Building HVAC Control System Interaction Issues: Two Case Studies  

E-Print Network (OSTI)

Direct Digital Control (DDC) allows HVAC equipment to be controlled at an upper level (supervisory control) through commands from a central system, or at a lower-level (local-loop control) by local controllers. The various levels of equipment...

Chen, Q.; Deng, S.; Toole, C.; Xu, C.

2007-01-01T23:59:59.000Z

151

Columbia Water and Light- Residential HVAC Rebate Program  

Energy.gov (U.S. Department of Energy (DOE))

Columbia Water and Light (CWL) provides an HVAC incentive for residential customers that are replacing an older heating and cooling system. Customers should submit the mechanical permit from a...

152

Industrial HVAC Air-to-Air Energy Recovery Retrofit Economics  

E-Print Network (OSTI)

Retrofitting air-to-air energy recovery equipment is relatively simply to design and easy to install. Additionally, HVAC energy recovery is almost risk free when compared to process retrofit. Life cycle cost analysis is the best way to illustrate...

Graham, E. L.

1980-01-01T23:59:59.000Z

153

EECBG Success Story: HVAC Upgrade Saving Money, Protecting History  

Energy.gov (U.S. Department of Energy (DOE))

With financial support from a $250,000 PA Conservation Works! grant – funded through the federal Energy Efficiency and Conservation Block Grant program and the Recovery Act – CCHS purchased a new Desert-Aire HVAC system. Learn more.

154

Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage  

E-Print Network (OSTI)

Optimised Scheduling of a Solar-Assisted HVAC System withA. Mammoli. Modeling of a solar-assisted HVAC system withOPTIMISED SCHEDULING OF A SOLAR-ASSISTED HVAC SYSTEM WITH

Mammoli, Andrea

2014-01-01T23:59:59.000Z

155

Comfort by Design: An Introduction to HVAC's Variable Refrigerant Flow (VRF) Technology  

E-Print Network (OSTI)

Comfort by Design An Introduction to HVAC’s Variable Refrigerant Flow (VRF) Technology Keith Reihl kreihl@hvac.mea.com ESL-KT-14-11-13 CATEE 2014: Clean Air Through Efficiency Conference, Dallas, Texas Nov. 18-20 HVAC Market Overview 0% 27% 9% 5% 4... Through Efficiency Conference, Dallas, Texas Nov. 18-20 How LOUD is a traditional HVAC unit? 33 dB(A) Library 50 dB(A) Refrigerator 60 dB(A) Conversation 78 dB(A) Vacuum 25 dB(A) Recording Studio 65-75 dB(A) Residential 3-ton HVAC Unit How Q IET are VRF...

Reihl,K.

2014-01-01T23:59:59.000Z

156

Residential HVAC Data, Assumptions and Methodology for End-Use Forecasting with EPRI-REEPS 2.1  

E-Print Network (OSTI)

Imports/Exports Gas Availability Change efficiency choice equation Add technologiestoHVAC model Adjust cost-efficiency parameter Develop HVAC Conversion

Johnson, F.X.

2010-01-01T23:59:59.000Z

157

Section 38 - HVAC (Heating, Ventilation, Air Conditioning)  

Science Journals Connector (OSTI)

The term HVAC is an acronym for Heating, Ventilation (and) Air Conditioning, the industry term for any of various efforts to control conditions in a building or other enclosed area to improve comfort and efficiency. A closely related section is Refrigeration, which follows this one. Some contemporary HVAC techniques have ancient roots. Early forms of central heating and solar home heating were in use in Rome in the first century A.D. The earliest use of glass in windows (as opposed to a covering of wood, cloth, or hide, or simply an opening) is also attributed to the Romans at this same time. The first known use of solar-oriented building design in North America dates back to about the year 1050; i.e., the cliff dwellings built by the Anasazi (Ancient Pueblo) people of the Colorado Plateau area. Geothermal district heating was employed as early as the 1300s, in the Auvergne region of southern France. The foundation for modern central heating was established in the 1700s, first in England and then in France. The 1800s saw significant advances in the use of water heaters, especially the first automatic storage water heater (Edwin Ruud, 1889) and the first commercial solar water heater (Clarence Kemp, 1891). In comparison with heating, cooling technology was late in developing. The first successful method of producing ice occurred in 1851, and it was not until 1902 that Willis Haviland Carrier designed the first industrial air-conditioning system. His Carrier Air Conditioning Corporation would go on to develop air-conditioning systems for stores and theaters (1924) and for residential buildings (1928). Carrier remains the global leader in air conditioner production. The first air-conditioned automobile was produced by Packard in 1939. Recent entries in this section emphasize the use of alternative energy sources in heating and cooling, such as solar, photovoltaic, geothermal, and fuel cells. These advances include the ground-source heat pump, the Trombe wall, the heat pipe, and the PV/thermal hybrid system.

Cutler J. Cleveland; Christopher Morris

2014-01-01T23:59:59.000Z

158

Inverted Attic Bulkhead for HVAC Ductwork, Roseville, California (Fact Sheet), Building America Case Study: Efficient Solutions for New and Existing Homes, Building Technologies Office (BTO)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Inverted Attic Bulkhead for Inverted Attic Bulkhead for HVAC Ductwork Roseville, California PROJECT INFORMATION Project Name: Long-Term Monitoring of Occupied Test House Location: Roseville, CA Partners: K. Hovnanian® Homes®, www.khov.com IBACOS www.ibacos.com Building Component: Envelope, structural, HVAC ducts Construction: New Application: New; single and/or multifamily Year Tested: 2012 Applicable Climate Zone(s): Hot-dry climate PERFORMANCE DATA HERS Index: 52 Projected Energy Savings: 11 million Btu/year heating and cooling savings Projected Energy Cost Savings: $116/year Modifying the truss system of a new home to accommodate ductwork within an inverted insulated bulkhead along the attic floor can save energy by placing

159

HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review ...  

Energy Savers (EERE)

HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review Presenter: Tony Bouza, U.S. Department of Energy This...

160

Airborne Particulate Matter in HVAC Systems and its Influence on Indoor Air Quality  

E-Print Network (OSTI)

This paper first reviews the mechanisms governing movement of PMs in HVAC systems. Then, the basic equations governing PM deposition in ducts are introduced and investigations on airborne PMs distribution in HVAC systems are reviewed. The influence...

Fu, Z.; Li, N.; Wang, H.

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hvac zone summary" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Building America Whole-House Solutions for New Homes: HVAC Design...  

Energy Savers (EERE)

HVAC Design Strategy for a Hot-Humid Production Builder Building America Whole-House Solutions for New Homes: HVAC Design Strategy for a Hot-Humid Production Builder In this...

162

CoolCab Thermal Load Reduction Project: CoolCalc HVAC Tool Development...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Thermal Load Reduction Project: CoolCalc HVAC Tool Development CoolCab Thermal Load Reduction Project: CoolCalc HVAC Tool Development 2010 DOE Vehicle Technologies and Hydrogen...

163

Direct Digital Control- A Tool for Energy Management of HVAC Systems  

E-Print Network (OSTI)

Direct digital control (DDC) applied to heating, ventilating, and air-conditioning (HVAC) systems corrects many of the deficiencies of conventional automatic temperature control systems. By applying new control sequences, DDC optimizes HVAC energy...

Swanson, K.

164

TITLE: HVAC TESTING & BALANCING FOR MAJOR AND MINOR PROJECTS OBJECTIVE AND  

E-Print Network (OSTI)

TITLE: HVAC TESTING & BALANCING FOR MAJOR AND MINOR PROJECTS OBJECTIVE AND PURPOSE: To provide an independent test & balance for the adjustment of all HVAC systems in all major projects and minor projects

Fernandez, Eduardo

165

Uncertainties in Achieving Energy Savings from HVAC Maintenance Measures in the Field  

E-Print Network (OSTI)

Uncertainties in Achieving Energy Savings from HVAC Maintenance Measures in the Field Kristin utilities across the nation to include HVAC maintenance measures in energy efficiency programs Maintenance measures have a significant potential for energy savings in residential and commercial unitary

California at Davis, University of

166

Air-Side Energy Use Calculations for Four HVAC Systems: Dual Duct Constant Volume (DDCAV), Dual Duct Variable Volume (DDVAV), Constant Volume with Reheat (CAVRH), Variable Volume with Reheat (VAVRH), Four Pipe Fan Coil Unit (FC), Four Pipe Induction Unit (FI), and Single Zone (SZ) Systems, Revised June 2002  

E-Print Network (OSTI)

(CAVRH), and variable volume with reheat (VAVRH), four pipe fan coil unit (FC), four pipe induction unit (FI), and a single zone air conditioning system (SZ). These calculations are presented in spreadsheets that include a running commentary so...

Haberl, J. S.; Bou-Saada, T. E.; Saman, N. F.

2001-01-01T23:59:59.000Z

167

Energy Savings Performance Contracts Summary  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

ENERGY SAVINGS PERFORMANCE CONTRACTS SUMMARY ENERGY SAVINGS PERFORMANCE CONTRACTS SUMMARY Site Contract Number Delivery or Task Order # Contractor Performance Period Contract Value Contract Description Richland DE-AC06-97RL13184 N/A Johnson Controls, Inc. 11/15/1996- 11/14/2021 $160.7M Conversion from central coal-fired steam plant to decentralized diesel boilers for Hanford Areas 200 & 300 (Site specific, standalone contract) DE-AM36-97EE73568 DE-AT06-09RL14923 Johnson Controls, Inc. 10/10/2008- 3/31/2033 $19.9M HVAC, Automation, Boiler Improvements Savannah River DE-AM36-02-NT41457 DE-AT09-09SR22572 Ameresco Federal Solutions 5/15/2009- 4/15/2031 $795M Biomass Cogeneration Facility and K and L Area Heating Plants

168

Data summary report of commercial building experiments in Salt Lake City,  

NLE Websites -- All DOE Office Websites (Extended Search)

Data summary report of commercial building experiments in Salt Lake City, Data summary report of commercial building experiments in Salt Lake City, UT from May 17 to June 10, 2002 Title Data summary report of commercial building experiments in Salt Lake City, UT from May 17 to June 10, 2002 Publication Type Report Year of Publication 2003 Authors Black, Douglas R., Tracy L. Thatcher, William W. Delp, Elisabeth A. Derby, Sheng-Chieh Chang, and Richard G. Sextro Abstract Under some circumstances, it may be desirable to provide all or part of a building with collective- protection against harmful chemical or biological (CB) agents. Collective-protection, as opposed to individual protection, uses the building -- its architecture, ventilation system, and control components -- to safeguard the health of the building occupants in the event of an indoor or outdoor release of toxic agents. In this study, we investigate the movement of tracer gases within a six-story building. The building was retrofitted to provide collective-protection on the upper two floors. To achieve this protection, the upper floors were over-pressurized using outside air that had passed through military specification carbon canisters and high-efficiency particulate air (HEPA) filters. The four lower floors were outside the collective-protection area and had a ventilation system that was retrofitted to provide response modes in the event of a CB release. These response modes (e.g. building flush and shelter in place) were designed to reduce the exposure of occupants on the lower floors without compromising the collective-protection zones. Over the course of four weeks, 16 tracer gas experiments were conducted to evaluate the collective- protection system (CPS) of the building's upper two floors and the ventilation response modes of the lower floors. Tracer gas concentrations were measured at a rate of 50 Hz in up to 30 locations in each experiment, which provided data with very high spatial and temporal resolution. Differential pressure and temperature measurements were also made throughout the building. Experiments showed that the CPS maintained a positive pressure differential between the upper two floors and the lower floors with various meteorological conditions and within specified settings of the HVAC fans serving the lower floors. However, the tracer experiments did show that a CB agent could enter the first zone of the decontamination areas on each CPS floor. Tracer gas analysis also showed that the shelter in place HVAC mode provided protection of lower floor occupants from an outdoor release by significantly lowering the air exchange rates on those floors. It was also determined that the efficacy of a flush mode triggered by an agent sensor depends greatly on the location of the sensor

169

Building energy modeling programs comparison Research on HVAC systems  

NLE Websites -- All DOE Office Websites (Extended Search)

energy modeling programs comparison Research on HVAC systems energy modeling programs comparison Research on HVAC systems simulation part Title Building energy modeling programs comparison Research on HVAC systems simulation part Publication Type Journal Year of Publication 2013 Authors Zhou, Xin, Da Yan, Tianzhen Hong, and Dandan Zhu Keywords Building energy modeling programs, comparison tests, HVAC system simulation, theory analysis Abstract Building energy simulation programs are effective tools for the evaluation of building energy saving and optimization of design. The fact that large discrepancies exist in simulated results when different BEMPs are used to model the same building has caused wide concern. Urgent research is needed to identify the main elements that contribute towards the simulation results. This technical report summarizes methodologies, processes, and the main assumptions of three building energy modeling programs (BEMPs) for HVAC calculations: EnergyPlus, DeST, and DOE-2.1E, and test cases are designed to analyze the calculation process in detail. This will help users to get a better understanding of BEMPs and the research methodology of building simulation. This will also help build a foundation for building energy code development and energy labeling programs.

170

Chapter 19: HVAC Controls (DDC/EMS/BAS) Evaluation Protocol  

SciTech Connect

The HVAC Controls Evaluation Protocol is designed to address evaluation issues for direct digital controls/energy management systems/building automation systems (DDC/EMS/BAS) that are installed to control heating, ventilation, and air-conditioning (HVAC) equipment in commercial and institutional buildings. (This chapter refers to the DDC/EMS/BAS measure as HVAC controls.) This protocol may also be applicable to industrial facilities such as clean rooms and labs, which have either significant HVAC equipment or spaces requiring special environmental conditions. This protocol addresses only HVAC-related equipment and the energy savings estimation methods associated with installing such control systems as an energy efficiency measure. The affected equipment includes: Air-side equipment (air handlers, direct expansion systems, furnaces, other heating- and cooling-related devices, terminal air distribution equipment, and fans); Central plant equipment (chillers, cooling towers, boilers, and pumps). These controls may also operate or affect other end uses, such as lighting, domestic hot water, irrigation systems, and life safety systems such as fire alarms and other security systems. Considerable nonenergy benefits, such as maintenance scheduling, system component troubleshooting, equipment failure alarms, and increased equipment lifetime, may also be associated with these systems. When connected to building utility meters, these systems can also be valuable demand-limiting control tools. However, this protocol does not evaluate any of these additional capabilities and benefits.

Romberger, J.

2014-11-01T23:59:59.000Z

171

Issue #3: HVAC Proper Installation Energy Savings: Over-Promising or Under-Delivering?  

Office of Energy Efficiency and Renewable Energy (EERE)

What energy savings are realistically achievable by following quality installation standards for installation, operation, and maintenance of residential HVAC?

172

Sentinel: Occupancy Based HVAC Actuation using Existing WiFi Infrastructure within Commercial Buildings  

E-Print Network (OSTI)

Sentinel: Occupancy Based HVAC Actuation using Existing WiFi Infrastructure within Commercial.agarwal@cs.cmu.edu ABSTRACT Commercial buildings contribute to 19% of the primary energy consumption in the US, with HVAC systems accounting for 39.6% of this usage. To reduce HVAC energy use, prior studies have pro- posed using

Gupta, Rajesh

173

Automated Testing of HVAC Systems for Commissioning Tim Salsbury and Rick Diamond  

E-Print Network (OSTI)

Automated Testing of HVAC Systems for Commissioning Tim Salsbury and Rick Diamond Lawrence Berkeley of the commissioning of HVAC systems. The approach is based on software that generates a sequence of test signals for new and retrofit projects. Introduction The performance of many HVAC systems is limited more by poor

Diamond, Richard

174

Co-simulation for performance prediction of integrated building and HVAC systems -An analysis of solution  

E-Print Network (OSTI)

Co-simulation for performance prediction of integrated building and HVAC systems - An analysis performance simulation of buildings and heating, ventilation and air- conditioning (HVAC) systems can help, heating, ventilation and air-conditioning (HVAC) systems are responsible for 10%-60% of the total building

175

Randomized Model Predictive Control for HVAC Systems Alessandra Parisio, Damiano Varagnolo, Daniel Risberg,  

E-Print Network (OSTI)

Randomized Model Predictive Control for HVAC Systems Alessandra Parisio, Damiano Varagnolo, Daniel Conditioning (HVAC) sys- tems play a fundamental role in maintaining acceptable ther- mal comfort and Indoor. A possible solu- tion is to develop effective control strategies for HVAC sys- tems, but this is complicated

Johansson, Karl Henrik

176

Theoretical Estimates of HVAC Duct Channel Capacity for High-Speed Internet Access  

E-Print Network (OSTI)

Theoretical Estimates of HVAC Duct Channel Capacity for High-Speed Internet Access Ariton E. Xhafa-conditioning (HVAC) ducts based on multi-carrier transmission that uses M-QAM mod- ulation and measured channel- flections in HVAC ducts). Our work also shows that data rates in excess of 300 Mbps are possible over

Stancil, Daniel D.

177

A LIBRARY OF HVAC COMPONENT MODELS FOR USE IN AUTOMATED1 DIAGNOSTICS2  

E-Print Network (OSTI)

A LIBRARY OF HVAC COMPONENT MODELS FOR USE IN AUTOMATED1 DIAGNOSTICS2 3 4 Peng Xu, Philip Haves HVAC system (air handling units and air distribution systems). The models are used to predict of automatic documentation methods in the library. INTRODUCTION The increasing complexity of building HVAC

178

Multi-carrier Signal Transmission through HVAC Ducts: Experimental Results for Channel Capacity  

E-Print Network (OSTI)

Multi-carrier Signal Transmission through HVAC Ducts: Experimental Results for Channel Capacity, for the first time, experimental results on channel capacity of heating, ventilation, and air-conditioning (HVAC through a building HVAC duct system demonstrate the ability to transmit with a spectral efficiency of 3

Stancil, Daniel D.

179

Seamless Handover in Buildings Using HVAC Ducts: A New System Architecture  

E-Print Network (OSTI)

Seamless Handover in Buildings Using HVAC Ducts: A New System Architecture Ariton E. Xhafa, Paisarn-- In this paper, we present an innovative solution to the handover problem in multi-story buildings using HVAC of the indoor wireless networks that use the heating, ventilation, and air conditioning (HVAC) ducts

Stancil, Daniel D.

180

Comparison of HVAC filter test methods for particle removal efficiency Brent Stephens1,*  

E-Print Network (OSTI)

Comparison of HVAC filter test methods for particle removal efficiency Brent Stephens1,* , Jeffrey Introduction The use of HVAC filters in buildings is one strategy to reduce occupant exposure to particulate matter. However, HVAC filters are typically tested only in laboratory settings and little is known about

Siegel, Jeffrey

Note: This page contains sample records for the topic "hvac zone summary" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

BLACK-BOX MODELLING OF HVAC SYSTEM: IMPROVING THE PERFORMANCES OF NEURAL NETWORKS  

E-Print Network (OSTI)

BLACK-BOX MODELLING OF HVAC SYSTEM: IMPROVING THE PERFORMANCES OF NEURAL NETWORKS Eric FOCK Ile de La Réunion - FRANCE ABSTRACT This paper deals with neural networks modelling of HVAC systems of HVAC system can be modelled using manufacturer design data presented as derived performance maps

Boyer, Edmond

182

Conventional Facilities Chapter 6: HVAC Systems 6-1 NSLS-II Preliminary Design Report  

E-Print Network (OSTI)

Conventional Facilities Chapter 6: HVAC Systems 6-1 NSLS-II Preliminary Design Report 6 MECHANICAL ­ HVAC SYSTEMS 6.1 Design Criteria 6.1.1 Codes and Standards The latest edition of the codes, standards have adequate capacity and head, no chilled water pumps #12;Conventional Facilities Chapter 6: HVAC

Ohta, Shigemi

183

RF propagation in an HVAC duct system: impulse response characteristics of the channel  

E-Print Network (OSTI)

RF propagation in an HVAC duct system: impulse response characteristics of the channel Pavel V, the heating, ventilation, and air conditioning (HVAC) duct system in buildings is a complex network of hollow at RF and microwave frequencies of com- mon interest. HVAC ducts can be used as a wireless communication

Stancil, Daniel D.

184

VOLUME 16, NUMBER 3 HVAC&R RESEARCH MAY 2010 The Effects of Filtration on  

E-Print Network (OSTI)

VOLUME 16, NUMBER 3 HVAC&R RESEARCH MAY 2010 273 The Effects of Filtration on Pressure Drop and Energy Consumption in Residential HVAC Systems (RP-1299) Brent Stephens Atila Novoselac, PhD Jeffrey A of high-efficiency HVAC filters is a common strategy to control exposure to airborne particulate matter

Siegel, Jeffrey

185

EVALUATION OF EMERGING DIAGNOSTIC TOOLS FOR COMMERCIAL HVAC SYSTEMS Hannah Friedman Mary Ann Piette  

E-Print Network (OSTI)

EVALUATION OF EMERGING DIAGNOSTIC TOOLS FOR COMMERCIAL HVAC SYSTEMS Hannah Friedman Mary Ann Piette for commercial HVAC systems. We present a brief description of the diagnostic tools, and then focus on evaluating, ventilating, and air-conditioning (HVAC) systems (Gregerson, 1997, Claridge et al., 2000). If these energy

186

Fuzzy Rule Reduction and Tuning of Fuzzy Logic Controllers for a HVAC System  

E-Print Network (OSTI)

Fuzzy Rule Reduction and Tuning of Fuzzy Logic Controllers for a HVAC System R. Alcal´a, J. Alcal, Ventilating and Air Conditioning (HVAC) Systems are equip- ments usually implemented for maintaining satisfactory comfort conditions in build- ings. The design of Fuzzy Logic Controllers (FLCs) for HVAC Systems

Granada, Universidad de

187

Tile of the document: HVAC system component-based modeling and implementation  

E-Print Network (OSTI)

1 Abstract Tile of the document: HVAC system component-based modeling and implementation Karam the foundation for modeling components that are used in HVAC systems (heating, ventilation, and air conditioning such functionalities. #12;2 HVAC system component-based modeling and implementation By Karam H. Rajab Scholarly

Austin, Mark

188

A CONTROLLER FOR HVAC SYSTEMS WITH FAULT DETECTION CAPABILITIES BASED ON SIMULATION MODELS  

E-Print Network (OSTI)

1 A CONTROLLER FOR HVAC SYSTEMS WITH FAULT DETECTION CAPABILITIES BASED ON SIMULATION MODELS T. I describes a control scheme with fault detection capabilities suitable for application to HVAC systems as a reference of correct operation. Faults that occur in the HVAC system under control cause the PI

189

Commissioning and Performance Diagnostics for HVAC Control Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

Commissioning and Performance Diagnostics for HVAC Control Systems Commissioning and Performance Diagnostics for HVAC Control Systems Speaker(s): Ashish Singhal Date: December 20, 2006 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Philip Haves The presentation will focus on practical aspects of commissioning control loops in commercial HVAC systems and evaluating their routine performance. Simple and theoretically sound methods for diagnosing control performance will be presented that detect serious performance issues associated with control loops in modern buildings. The discussion will center on a new control loop commissioning tool that helps field personnel to quickly test, tune and troubleshoot control loops. In addition to the active tests for commissioning control loops, a suite of diagnostic algorithms are used in a

190

Optimized HVAC Management Service to Enhance Demand Response  

NLE Websites -- All DOE Office Websites (Extended Search)

Optimized HVAC Management Service to Enhance Demand Response Optimized HVAC Management Service to Enhance Demand Response Speaker(s): John Steinberg Date: August 18, 2011 - 12:00pm Location: 90-4133 Seminar Host/Point of Contact: Janie Page Many utilities are investing vast sums deploying smart meters to customers, some of whom remain stubbornly opposed to those deployments, in large part because they remain unmoved by the claimed benefits. EcoFactor has developed a thermostat management service that delivers (and quantifies) significant energy savings for consumers and a number of additional benefits to other players in the energy value chain. It does so without relying on consumers to modify behavior, study energy information displays, or even pay attention to their energy use. EcoFactor also significantly boosts DR yield while it increases occupant comfort. It can identify HVAC

191

Energy-Efficient Building HVAC Control Using Hybrid System LBMPC  

E-Print Network (OSTI)

Improving the energy-efficiency of heating, ventilation, and air-conditioning (HVAC) systems has the potential to realize large economic and societal benefits. This paper concerns the system identification of a hybrid system model of a building-wide HVAC system and its subsequent control using a hybrid system formulation of learning-based model predictive control (LBMPC). Here, the learning refers to model updates to the hybrid system model that incorporate the heating effects due to occupancy, solar effects, outside air temperature (OAT), and equipment, in addition to integrator dynamics inherently present in low-level control. Though we make significant modeling simplifications, our corresponding controller that uses this model is able to experimentally achieve a large reduction in energy usage without any degradations in occupant comfort. It is in this way that we justify the modeling simplifications that we have made. We conclude by presenting results from experiments on our building HVAC testbed, which s...

Aswani, Anil; Taneja, Jay; Krioukov, Andrew; Culler, David; Tomlin, Claire

2012-01-01T23:59:59.000Z

192

Ameren Illinois (Electric) - Custom, HVAC, and Motor Business Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ameren Illinois (Electric) - Custom, HVAC, and Motor Business Ameren Illinois (Electric) - Custom, HVAC, and Motor Business Efficiency Incentives Ameren Illinois (Electric) - Custom, HVAC, and Motor Business Efficiency Incentives < Back Eligibility Commercial Industrial Multi-Family Residential Nonprofit Savings Category Other Heating & Cooling Commercial Heating & Cooling Cooling Home Weatherization Construction Commercial Weatherization Design & Remodeling Manufacturing Sealing Your Home Ventilation Heat Pumps Heating Appliances & Electronics Commercial Lighting Lighting Water Heating Maximum Rebate $600,000/year/facility. Incentives $1-$200,000: paid at 100% Incentives $200,000-$600,000: paid at 50% Custom: 50% of incremental cost Retro-Commissioning: $200,000/year/facility; $100,000/project Leak Survey: $10,000

193

Optimizing HVAC Control to Improve Building Comfort and Energy Performance  

E-Print Network (OSTI)

This paper demonstrates the benefits of optimal control in well-designed and operated buildings using a case study. The case study building was built in 2001. The HVAC and control systems have been installed with state-of-the-art equipment which...

Song, L.; Joo, I.; Dong, D.; Liu, M.; Wang, J.; Hansen, K.; Quiroz, L.; Swiatek, A.

2003-01-01T23:59:59.000Z

194

Air filtration: Choosing the right filter class for HVAC systems  

Science Journals Connector (OSTI)

As anyone who works with air filtration knows, getting the best from a system is about more than choosing efficient media and correct installation. Thomas Carlson of Vokes Air explains the importance of using and selecting the right filter class for a typical HVAC system.

Thomas Carlson

2008-01-01T23:59:59.000Z

195

Performance Validation and Energy Analysis of HVAC Systems using Simulation  

E-Print Network (OSTI)

that energy savings of between 15% and 40% could be made in commercial buildings by closer monitoring and supervision of energy-usage and related data. An earlier study by Kao and Pierce (1983) showed that sensor1 Performance Validation and Energy Analysis of HVAC Systems using Simulation Tim Salsbury and Rick

Diamond, Richard

196

Decision Summaries  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

oha/decision-summaries Office of Hearings and Appeals oha/decision-summaries Office of Hearings and Appeals 1000 Independence Ave., SW Washington, DC, 20585 202-287-1566 en Summary of Decisions - December 30, 2013 - January 3, 2014 http://energy.gov/oha/articles/summary-decisions-december-30-2013-january-3-2014 summary-decisions-december-30-2013-january-3-2014" class="title-link">Summary of Decisions - December 30, 2013 - January 3, 2014

197

Ventilation, temperature, and HVAC characteristics in small and medium  

NLE Websites -- All DOE Office Websites (Extended Search)

Ventilation, temperature, and HVAC characteristics in small and medium Ventilation, temperature, and HVAC characteristics in small and medium commercial buildings in California Title Ventilation, temperature, and HVAC characteristics in small and medium commercial buildings in California Publication Type Journal Article Refereed Designation Refereed Year of Publication 2012 Authors Bennett, Deborah H., William J. Fisk, Michael G. Apte, X. Wu, Amber L. Trout, David Faulkner, and Douglas P. Sullivan Journal Indoor Air Volume 22 Issue 4 Pagination 309-20 Abstract This field study of 37 small and medium commercial buildings throughout California obtained information on ventilation rate, temperature, and heating, ventilating, and air-conditioning (HVAC) system characteristics. The study included seven retail establishments; five restaurants; eight offices; two each of gas stations, hair salons, healthcare facilities, grocery stores, dental offices, and fitness centers; and five other buildings. Fourteen (38%) of the buildings either could not or did not provide outdoor air through the HVAC system. The air exchange rate averaged 1.6 (s.d. = 1.7) exchanges per hour and was similar between buildings with and without outdoor air supplied through the HVAC system, indicating that some buildings have significant leakage or ventilation through open windows and doors. Not all buildings had sufficient air exchange to meet ASHRAE 62.1 Standards, including buildings used for fitness centers, hair salons, offices, and retail establishments. The majority of the time, buildings were within the ASHRAE temperature comfort range. Offices were frequently overcooled in the summer. All of the buildings had filters, but over half the buildings had a filter with a minimum efficiency reporting value rating of 4 or lower, which are not very effective for removing fine particles. PRACTICAL IMPLICATIONS: Most U.S. commercial buildings (96%) are small- to medium-sized, using nearly 18% of the country's energy, and sheltering a large population daily. Little is known about the ventilation systems in these buildings. This study found a wide variety of ventilation conditions, with many buildings failing to meet relevant ventilation standards. Regulators may want to consider implementing more complete building inspections at commissioning and point of sale.

198

Assessment of organic compound exposures, thermal comfort parameters, and HVAC system-driven air exchange rates in public school portable classrooms in California  

E-Print Network (OSTI)

no no, y e s - only HVAC filters: sizes, when changed 68%n=2) (n=19) 100% no 95% no Current HVAC air filter was notoriginal When HVAC air filter was last changed (reported as

Shendell, Derek Garth

2010-01-01T23:59:59.000Z

199

Two Alabama Elementary Schools Get Cool with New HVAC Units | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Alabama Elementary Schools Get Cool with New HVAC Units Alabama Elementary Schools Get Cool with New HVAC Units Two Alabama Elementary Schools Get Cool with New HVAC Units October 1, 2010 - 2:05pm Addthis Winston County School District will receive 14 new HVAC units with State Energy Program funding. | File photo Winston County School District will receive 14 new HVAC units with State Energy Program funding. | File photo Lindsay Gsell What are the key facts? Two public elementary schools receive 14 new HVAC units for classrooms. School district estimates nearly 10 percent in electrical savings with new units. Nineteen Alabama public school districts using Recovery Act grants to save energy and money. Addison Elementary School and Double Springs Elementary School in northwestern Alabama were warm. Some classrooms just didn't cool fast enough. The buildings, which were

200

Microsoft Word - Key-note-Cold climate_HVAC2009-neuer.docx  

NLE Websites -- All DOE Office Websites (Extended Search)

software tools for moisture Protection of buildings in software tools for moisture Protection of buildings in different climate zones Special Example: Control of air humidifier in a cold climate for high comfort and no risk of mould growth in building room Krus Martin 1* , Thierry Nouidui 1 and Sedlbauer Klaus 1 1 Fraunhofer Institute for Building Physics, Germany * Corresponding email: Martin.Krus@ibp.fraunhofer.de SUMMARY The application of software tools for moisture protection of buildings in different climatic zones is demonstrated in this paper. The basics of the programs are presented together with a typical application for a problem specific for the chosen climatic zone. A 1-D calculation has been performed for tropical climate zone with the improvement of a flat roof in Bangkok as an example. For half timbered buildings, which are common in the temperate zone with the

Note: This page contains sample records for the topic "hvac zone summary" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

HVAC Radial Air Bearing Heat Exchangers Research Project | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Radial Air Bearing Heat Exchangers Radial Air Bearing Heat Exchangers Research Project HVAC Radial Air Bearing Heat Exchangers Research Project The U.S. Department of Energy is currently conducting research into heating, ventilation, and air conditioning (HVAC) radial air bearing heat exchangers. Rotary air bearing heat exchanger technology simultaneously solves four long standing problems of conventional "fan-plus-finned-heat-sink" heat exchangers. Project Description This project seeks to design, fabricate, and test successive generations of prototype radial air bearing heat exchanger devices based on lessons learned and further insights into device optimization, computational fluid dynamic studies for parametric optimization and determination of scaling laws, and laboratory measurement of flow field and heat transfer

202

Free-cooling: A total HVAC design concept  

SciTech Connect

This paper discusses a total ''free cooling'' HVAC design concept in which mechanical refrigeration is practically obviated via the refined application of existing technological strategies and a new diffuser terminal. The principles being applied are as follows; Thermal Swing: This is the active contribution of programmed heat storage to overall HVAC system performance. Reverse Diffuser: This is a new air terminal design that facilitates manifesting the thermal storage gains. Developing the thermal storage equation system into a generalized simulation model, optimizing the thermal storage and operating strategies with a computer program and developing related algorithms are subsequently illustrated. Luminair Aspiration: This feature provides for exhausting all luminair heat totally out of the building envelope, via an exhaust duct system and insulated boots. Two/Three-Stage Evaporative Cooling: This concept comprises a system of air conditioning that entails a combination of closed and open loop evaporative cooling with standby refrigeration only.

Janeke, C.E.

1982-01-01T23:59:59.000Z

203

Quantitative Methods for Comparing Different HVAC Control Schemes  

E-Print Network (OSTI)

Experimentally comparing the energy usage and comfort characteristics of different controllers in heating, ventilation, and air-conditioning (HVAC) systems is difficult because variations in weather and occupancy conditions preclude the possibility of establishing equivalent experimental conditions across the order of hours, days, and weeks. This paper is concerned with defining quantitative metrics of energy usage and occupant comfort, which can be computed and compared in a rigorous manner that is capable of determining whether differences between controllers are statistically significant in the presence of such environmental fluctuations. Experimental case studies are presented that compare two alternative controllers (a schedule controller and a hybrid system learning-based model predictive controller) to the default controller in a building-wide HVAC system. Lastly, we discuss how our proposed methodology may also be able to quantify the efficiency of other building automation systems.

Aswani, Anil; Taneja, Jay; Krioukov, Andrew; Culler, David; Tomlin, Claire

2012-01-01T23:59:59.000Z

204

Plutonium Finishing Plant (PFP) HVAC System Component Index  

SciTech Connect

This document lists safety class (SC) and safety significant (SS) components for the Heating Ventilation Air Conditioning (HVAC) and specifies the critical characteristics for Commercial Grade Items (CGI), as required by HNF-PRO-268 and HNF-PRO-18 19. These are the minimum specifications that the equipment must meet in order to properly perform its safety function. There may be several manufacturers or models that meet the critical characteristics for any one item. The Plutonium Finishing Plant (PFP) HVAC System includes sub-systems 25A through 25K. Specific system boundaries and justifications are contained in HNF-SD-CP-SDD-005, ''Definition and Means of Maintaining the Ventilation System Confinement Portion of the PFP Safety Envelope.'' The procurement requirements associated with the system necessitates procurement of some system equipment as Commercial Grade Items in accordance with HNF-PRO-268, ''Control of Purchased Items and Services.''

DIAZ, E.N.

2000-03-30T23:59:59.000Z

205

HVAC Optimized Heat Exchangers Research Project | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Optimized Heat Exchangers Research Optimized Heat Exchangers Research Project HVAC Optimized Heat Exchangers Research Project The U.S. Department of Energy is currently conducting research into heating, ventilation, and air conditioning (HVAC) optimized heat exchangers. The information generated in this study will demonstrate performance improvements that can be achieved through optimization of refrigerant circuitry for non-uniform inlet air distribution. The tubing circuitry on fin-tube heat exchangers used in residential space-conditioning systems is typically designed assuming uniform airflow through the finned passageways. However, the air flow in installed systems is highly non-uniform, resulting in mismatched refrigerant-air heat transfer that reduces the capacity of the heat exchanger and efficiency of

206

An Application of State-Of-The-Art HVAC and Building Systems  

E-Print Network (OSTI)

AN APPLICATION OF STATE-OF-THE-ART HVAC AND BUILDING SYSTEMS DONALD P. FIORINO, M.S., P.E. Energy Conservation Manager Texas Instruments, Inc. Defense Systems and Electronics Group Dallas, Texas ABSTRACT This case study describes... the successful application of state-of-the-art HVAC and building systems at a large commercial office and industrial facility. The facility's exterior envelope systems, HVAC systems, lighting systems, energy conservation systems, exhaust/heat recovery...

Fiorino, D. P.

207

Total Quality Commissioning for HVAC Systems to Assure High Performance Throughout the Whole Life Cycle  

E-Print Network (OSTI)

TOTAL QUALITY COMMISSIONING FOR HVAC SYSTEMS TO ASSURE HIGH PERFORMANCE THROUGHOUT THE WHOLE LIFE CYCLE By: Grahame E. Maisey, P.E., and Beverly Milestone, LEED AP Building Services Consultants INTRODUCTION Current HVAC systems... are not coming close to approaching life cycle performance expectations for energy, operation and maintenance, occupant comfort and productivity and longevity. HVAC systems in buildings claiming to be sustainable, with integrated, energy conscious design...

Maisey, G.; Milestone, B.

2005-01-01T23:59:59.000Z

208

E-Print Network 3.0 - aktivnoj zone vodo-vodyanogo Sample Search...  

NLE Websites -- All DOE Office Websites (Extended Search)

Engineering 13 Brandeis University Authorization for Payroll Deduction Purchase of MBTA Commuter Pass Summary: :) Zone 1 135.00 Zone 2 151.00 ...

209

E-Print Network 3.0 - aktivnoj zone rabotayushchego Sample Search...  

NLE Websites -- All DOE Office Websites (Extended Search)

Engineering 13 Brandeis University Authorization for Payroll Deduction Purchase of MBTA Commuter Pass Summary: :) Zone 1 135.00 Zone 2 151.00 ...

210

E-Print Network 3.0 - active fault zone Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

Earth Structure (2nd Edition), 2004 Summary: 292010 Oceanic Transform Faults and Fracture Zones Transform Fault: Active displacement. Fracture Zone: Fossil... fault, no active...

211

Outdoor airflow into HVAC systems: An evaluation of measurement  

NLE Websites -- All DOE Office Websites (Extended Search)

Outdoor airflow into HVAC systems: An evaluation of measurement Outdoor airflow into HVAC systems: An evaluation of measurement technologies Title Outdoor airflow into HVAC systems: An evaluation of measurement technologies Publication Type Report LBNL Report Number LBNL-53834 Year of Publication 2003 Authors Fisk, William J., David Faulkner, Douglas P. Sullivan, and William W. Delp Abstract During the last few years, new technologies have been introduced for measuring the flow rates of outdoor air (OA) into HVAC systems; however, an evaluation of these measurement technologies has not previously been published. This document describes a test system and protocols developed for controlled evaluation of these measurement technologies. The results of tests of three measurement technologies are also summarized. The test system and protocol were judged practical and very useful. The test results indicate that one measurement technology can measure OA flow rates with errors of 20% or less without a field-based calibration, as long as the OA velocities are sufficient to provide an accurately measurable pressure signal. The test results for a second measurement technology are similar; however, a difficult field-based calibration relating the OA flow rate with the pressure signal would be required to reduce errors below approximately 30%. The errors in OA flow rates measured with the third measurement technology, that uses six electronic airspeed sensors downstream of the OA inlet louver, exceeded 100%; however, these errors could be substantially reduced through a difficult field based calibration. The effects of wind on the accuracy of these measurement technologies still needs to be evaluated

212

Measuring rates of outdoor airflow into HVAC systems  

SciTech Connect

During the last few years, new technologies have been introduced for measuring the flow rates of outside air into HVAC systems. This document describes one particular technology for measuring these airflows, a system and a related protocol developed to evaluate this and similar measurement technologies under conditions without wind, and the results of our evaluations. We conclude that the measurement technology evaluated can provide a reasonably accurate measurement of OA flow rate over a broad range of flow, without significantly increasing airflow resistance.

Fisk, William J.; Faulkner, David; Sullivan, Douglas P.; Delp, Woody

2002-10-01T23:59:59.000Z

213

DOE Zero Energy Ready Home Low Load High Efficiency HVAC Webinar (Text Version)  

Energy.gov (U.S. Department of Energy (DOE))

Below is the text version of the DOE Zero Energy Ready Home webinar, Low Load High Efficiency HVAC, presented in May 2014.

214

Characterization of the HVAC performance with defroster grillers and instrument panel registers  

Science Journals Connector (OSTI)

Improving HVAC performance is of paramount importance to sustain ... was between 15 to 25 degrees with a standard distance ratio of one. During the cooling...

M. F. Kader; Y. M. Youn; Y. D. Jun…

2009-06-01T23:59:59.000Z

215

E-Print Network 3.0 - air conditioning hvac Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

systems play an important role in providing comfort in residential, commercial... of Heating, Refrigerating, and Air-Conditioning Engineers. Batterman S. and Burge H. 1995. "HVAC...

216

Numerical Investigation of Flow Induced Noise in a Simplified HVAC Duct with OpenFOAM.  

E-Print Network (OSTI)

?? Due to the growing demand for comfort, the noise generated by HVAC components should be considered by the designers. Flow induced noise is one… (more)

Wang, Cong

2013-01-01T23:59:59.000Z

217

REDESIGN OF HVAC SYSTEM TO IMPROVE ENERGY EFFICIENCY OF EDUCATIONAL BUILDING.  

E-Print Network (OSTI)

??An energy modeling software was used to analyze the current building configuration and simulations were performed in an attempt to redesign the current HVAC system… (more)

Hagene, Brian Matthew

2012-01-01T23:59:59.000Z

218

Energy Consumption Analyses of Frequently-used HVAC System Types in High Performance Office Buildings.  

E-Print Network (OSTI)

??The high energy consumption of heating, ventilation and air-conditioning (HVAC) systems in commercial buildings is a hot topic. Office buildings, a typical building set of… (more)

Yan, Liusheng

2014-01-01T23:59:59.000Z

219

Development of a High-Efficiency Zonal Thermoelectric HVAC System for Automotive Applications  

Energy.gov (U.S. Department of Energy (DOE))

Identify a technical and business approach to accelerate the deployment of light-duty automotive TE HVAC technology, maintain occupant comfort, and improve energy efficiency.

220

Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage  

E-Print Network (OSTI)

solar energy available would result in overcharging of the hot storage.of a solar-assisted HVAC system with thermal storage. Energystorage and solar- assisted HVAC for the purpose of optimizing its energy

Mammoli, Andrea

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hvac zone summary" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage  

E-Print Network (OSTI)

of a solar-thermal- assisted hvac system. Energy andsolar thermal collectors using flat reflective surfaces. Solar Energy,of a solar-assisted HVAC system with thermal storage. Energy

Mammoli, Andrea

2014-01-01T23:59:59.000Z

222

Procedures to identify Energy Conservation Opportunities applied to HVAC system: example of VSD of chilled water pumps  

E-Print Network (OSTI)

Procedures to identify Energy Conservation Opportunities applied to HVAC system: example of VSD of HVAC equipment using variable speed drive (VSD) is an Energy Conservation Opportunity (ECO) which can

Paris-Sud XI, Université de

223

Proceedings of Healthy Buildings 2009 Paper 535 HVAC filters as "passive" samplers: fate analysis of indoor particles  

E-Print Network (OSTI)

Proceedings of Healthy Buildings 2009 Paper 535 HVAC filters as "passive" samplers: fate analysis the effectiveness of using HVAC filters as an indoor sampling technique. #12;Proceedings of Healthy Buildings 2009

Siegel, Jeffrey

224

Proposal for the Award of a Contract for Maintenance, Operation and Minor Installation Work for CERN Cooling and HVAC Systems  

E-Print Network (OSTI)

Proposal for the Award of a Contract for Maintenance, Operation and Minor Installation Work for CERN Cooling and HVAC Systems

1996-01-01T23:59:59.000Z

225

Program Summaries  

Office of Science (SC) Website

Program Summaries Program Summaries Basic Energy Sciences (BES) BES Home About Research Facilities Science Highlights Benefits of BES Funding Opportunities Basic Energy Sciences Advisory Committee (BESAC) News & Resources Program Summaries Brochures Reports Accomplishments Presentations BES and Congress Science for Energy Flow Seeing Matter Scale of Things Chart Contact Information Basic Energy Sciences U.S. Department of Energy SC-22/Germantown Building 1000 Independence Ave., SW Washington, DC 20585 P: (301) 903-3081 F: (301) 903-6594 E: sc.bes@science.doe.gov More Information » News & Resources Program Summaries Print Text Size: A A A RSS Feeds FeedbackShare Page Bes Summaries 2012 thumbnail JPG .jpg file (469KB) Basic Energy Sciences FY 2012 Research Summaries This report provides a collection of research abstracts and highlights for

226

Minimization of energy consumption in HVAC systems with data-driven models and an interior-point method  

E-Print Network (OSTI)

Minimization of energy consumption in HVAC systems with data-driven models and an interior online 13 June 2014 Keywords: HVAC Interior-point method Internal heat gain Multilayer perceptron-driven approach is applied to minimize energy consumption of a heating, ventilating, and air conditioning (HVAC

Kusiak, Andrew

227

HVAC Component Data Modeling Using Industry Foundation Classes Vladimir Bazjanac, Lawrence Berkeley National Laboratory, U.S.A.  

E-Print Network (OSTI)

1 HVAC Component Data Modeling Using Industry Foundation Classes Vladimir Bazjanac, Lawrence. This paper describes a number of aspects of a major extension of the HVAC part of the IFC data model. First is the introduction of a more generic approach for handling HVAC components. This includes type information, which

228

Residential HVAC Data, Assumptions and Methodology for End-Use Forecasting with EPRI-REEPS 2.1  

E-Print Network (OSTI)

LBL-34045 UC-1600 Residential HVAC Data, Assumptions and Methodology for End-Use Forecasting-uses include Heating, Ventilation and Air Conditioning (HVAC). Our analysis uses the modeling framework provided by the HVAC module in the Residential End-Use Energy Planning System (REEPS), which was developed

229

1736 IEEE TRANSACTIONS ON COMMUNICATIONS, VOL. 51, NO. 10, OCTOBER 2003 Impulse Response of the HVAC Duct as a  

E-Print Network (OSTI)

of the HVAC Duct as a Communication Channel Pavel V. Nikitin, Member, IEEE, Daniel D. Stancil, Senior Member (HVAC) ducts in buildings behave as multimode waveguides when excited at radio frequencies and thus, can of a usual indoor propagation channel. In this paper, we describe physical mechanisms which affect the HVAC

Hochberg, Michael

230

7/11/00-draft copy: do not quote 1 of 30 New Technologies for Residential HVAC Ducts  

E-Print Network (OSTI)

7/11/00-draft copy: do not quote 1 of 30 New Technologies for Residential HVAC Ducts Burke Treidler is not evaluated and HVAC contractors overcome duct system shortcomings by installing oversized equipment Technologies for Residential HVAC Ducts fittings with some use of ductboard. Fittings that snap together were

231

IEEE TRANSACTIONS ON COMMUNICATIONS, VOL. 53, NO. 2, FEBRUARY 2005 335 On the Capacity Limits of HVAC Duct Channel for  

E-Print Network (OSTI)

of HVAC Duct Channel for High-Speed Internet Access Ariton E. Xhafa, Member, IEEE, Ozan K. Tonguz, Member and experimental channel-capacity estimates of heating, ventilation, and air condi- tioning (HVAC) ducts based suppressed. Our experimental results also show that even in the case of more complex HVAC duct networks (i

Stancil, Daniel D.

232

An experimental system for advanced heating, ventilating and air conditioning (HVAC) control  

Science Journals Connector (OSTI)

While having the potential to significantly improve heating, ventilating and air conditioning (HVAC) system performance, advanced (e.g., optimal, robust and various forms of adaptive) controllers have yet to be incorporated into commercial systems. Controllers consisting of distributed proportional-integral (PI) control loops continue to dominate commercial HVAC systems. Investigation into advanced HVAC controllers has largely been limited to proposals and simulations, with few controllers being tested on physical systems. While simulation can be insightful, the only true means for verifying the performance provided by HVAC controllers is by actually using them to control an HVAC system. The construction and modeling of an experimental system for testing advanced HVAC controllers, is the focus of this article. A simple HVAC system, intended for controlling the temperature and flow rate of the discharge air, was built using standard components. While only a portion of an overall HVAC system, it is representative of a typical hot water to air heating system. In this article, a single integrated environment is created that is used for data acquisition, controller design, simulation, and closed loop controller implementation and testing. This environment provides the power and flexibility needed for rapid prototyping of various controllers and control design methodologies.

Michael Anderson; Michael Buehner; Peter Young; Douglas Hittle; Charles Anderson; Jilin Tu; David Hodgson

2007-01-01T23:59:59.000Z

233

HVAC filter bypass modelling and experimental validation Jeffrey A. Siegel1,*  

E-Print Network (OSTI)

standards that address HVAC filtration efficacy including ASHRAE Standard 52.2 (ASHRAE, 2007) and EN 779HVAC filter bypass modelling and experimental validation Jeffrey A. Siegel1,* , David B. Chojnowski of filter bypass, an ASHRAE Standard 52.2-2007 compliant apparatus was modified to accept filters

Siegel, Jeffrey

234

Co-design of control algorithm and embedded platform for building HVAC systems  

Science Journals Connector (OSTI)

The design of heating, ventilation and air conditioning (HVAC) systems is crucial for reducing energy consumption in buildings. As complex cyber-physical systems, HVAC systems involve three closely-related subsystems -- the control algorithm, the physical ... Keywords: building energy efficiency, co-design, platform-based design

Mehdi Maasoumy; Qi Zhu; Cheng Li; Forrest Meggers; Alberto Sangiovanni-Vincentelli

2013-04-01T23:59:59.000Z

235

Fouling of HVAC Fin and Tube Heat Exchangers Jeffrey Siegel and Van P. Carey  

E-Print Network (OSTI)

Fouling of heat exchangers used in heating, ventilating, and air conditioning (HVAC) systems is important contributor to overall energy use and peak electric demand. Furthermore, the location of heat exchangers in HVAC systems means that if bioaerosols containing bacteria, fungi, and viruses deposit on heat

236

Energy Savings with Energy-Efficient HVAC Systems in Commercial Buildings of Hong Kong  

E-Print Network (OSTI)

of the electricity in Hong Kong is consumed by commercial buildings, and heating, ventilation and air-conditioning (HVAC) is the largest end-user in such buildings, improving the efficiency of HVAC systems in commercial buildings, is the key measure to take in Hong...

Yang, J.; Chan, K.; Wu, X.

2006-01-01T23:59:59.000Z

237

Electric, Gas, and Electric/Gas Energy Options for Cold-Air HVAC Systems  

E-Print Network (OSTI)

An important aspect of the design of cost-effective HVAC systems today is (a) sensitivity to the cost impact of the interplay of utility demand charges, time-of-day rates, gas rates, and gas/electric utility incentive programs vis-à-vis HVAC system...

Meckler, G.

1989-01-01T23:59:59.000Z

238

Development of New HVAC Design Tools: Search for the Holy Grail of  

NLE Websites -- All DOE Office Websites (Extended Search)

Development of New HVAC Design Tools: Search for the Holy Grail of Development of New HVAC Design Tools: Search for the Holy Grail of Ventilation Research Speaker(s): Jelena Srebric Date: January 29, 2004 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: William Fisk HVAC systems are very important to our wellbeing, energy, and the environment. Current design tools are typically supported by basic knowledge, and keep us at arm's length from the many practical problems. The design paradigm has been shifted several times in the past from thermal comfort, energy conservation, health concerns, and now probably to security issues. Each of the shift has required better design tools of HVAC systems.A team led by Dr. Jelena Srebric at the Department of Architecture, the Penn State University (PSU) is developing new HVAC design tools to meet

239

Source attenuating HVAC equipment—Just the facts  

Science Journals Connector (OSTI)

Current classroom designs range from NC 63 to NC 25. The ASA/ANSI 12.60 Classroom Standard sets a relatively low background sound requirement for classrooms. Achieving 12.60 levels economically requires the maximum in source sound attenuation. This paper will provide a manufacturer’s perspective on current and low noiseHVAC products and the resulting classroomsound levels. Predictive acoustics software will be used to predict the space sound power level and some indication of equipment cost will be provided in order to assist designers in what is the best approach to low noiseclassroom design.

2004-01-01T23:59:59.000Z

240

Decomposition of formaldehyde by EPD photocatalyst filters in HVAC  

Science Journals Connector (OSTI)

This study used electrophoretic deposition (EPD) to apply titanium oxide (TiO2) coating on stainless steel filters and investigated the effectiveness of photocatalytic oxidation of formaldehyde by TiO2 under various conditions of heating ventilation air conditioning (HVAC). The results showed photocatalytic efficiency could reach 35.59% at 21 °C and 36.39% at 26 °C with 7 photocatalyst filters and 5 UVC lamps, the overall efficiency of formaldehyde removal of 52.37% at 21 °C, and 56.8% at 26 °C. By all experimental data can be found that the temperature for the photocatalytic performance is not obvious in the range of this study.

Chien-Chih Chen; Ching-Song Jwo; Tun-Ping Teng

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hvac zone summary" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Thermal Modeling for a HVAC Controlled Real-life Yong Fu1, Mo Sha1, Chengjie Wu1, Andrew Kutta1, Anna Leavey2, Chenyang Lu1,  

E-Print Network (OSTI)

Thermal Modeling for a HVAC Controlled Real-life Auditorium Yong Fu1, Mo Sha1, Chengjie Wu1, Andrew consumption in build- ings is heating, ventilation, and air conditioning (HVAC). For an HVAC system to provide, especially in large open spaces. To optimize HVAC control, it is important to establish accurate dynamic

Lu, Chenyang

242

PV modules, with a life measured in decades, will typically be in place longer than the outdoor unit of a HVAC system.  

E-Print Network (OSTI)

unit of a HVAC system. When the performance of an HVAC system deteriorates, it is usually inspected remain installed on the roof even after the system is no longer being used. Although HVAC units have only jumpers and screws effectively bond all parts of the listed device together. HVAC components are typically

Johnson, Eric E.

243

Fouling of HVAC fin and tube heat exchangers  

SciTech Connect

Fin and tube heat exchangers are used widely in residential, commercial and industrial HVAC applications. Invariably, indoor and outdoor air contaminants foul these heat exchangers. This fouling can cause decreased capacity and efficiency of the HVAC equipment as well as indoor air quality problems related to microbiological growth. This paper describes laboratory studies to investigate the mechanisms that cause fouling. The laboratory experiments involve subjecting a 4.7 fins/cm (12 fins/inch) fin and tube heat exchanger to an air stream that contains monodisperse particles. Air velocities ranging from 1.5-5.2 m/s (295 ft/min-1024 ft/min) and particle sizes from 1--8.6 {micro}m are used. The measured fraction of particles that deposit as well as information about the location of the deposited material indicate that particles greater than about 1 {micro}m contribute to fouling. These experimental results are used to validate a scaling analysis that describes the relative importance of several deposition mechanisms including impaction, Brownian diffusion, turbophoresis, thermophoresis, diffusiophoresis, and gravitational settling. The analysis is extended to apply to different fin spacings and particle sizes typical of those found in indoor air.

Siegel, Jeffrey; Carey, Van P.

2001-07-01T23:59:59.000Z

244

Sound quality descriptors for HVAC equipment from ARI Standards  

Science Journals Connector (OSTI)

The Air Conditioning and Refrigeration Institute (ARI) has several standards that provide methods to evaluate the sound quality of heating ventilating and air?conditioning (HVAC) equipment. These include Standard 270 Sound rating of outdoor unitary equipment Standard 350 Sound rating of non?ducted indoor air?conditioning equipment and Standard 1140P Procedures for evaluating sound quality of HVAC equipment. The preferred method in these standards is best described in Standard 1140P which uses one?third octave band sound power levels that are weighted to adjust for the sensitivity to frequency distribution and presence of tones and are then converted to a single number sound quality indicator. The tone adjustment is based on the projection of a given one?third octave band level relative to the average of the adjacent one?third octave bands. An alternate use of Zwicker method B to determine loudness and loudness level is also provided in ARI Standard 1140P. These standards provide a convenient method by which complex sounds for similar products may be compared.

2003-01-01T23:59:59.000Z

245

Commissioning of Building HVAC Systems for Improved Energy Performance: A Summary of Annex 40 Results  

E-Print Network (OSTI)

( Japan, France, Canada, Belgium, Switzerland, Sweden, USA, Germany, Norway, Finland) took part as full members, observers participated from 4 other countries (The Netherlands, Korea, China, Hungary). The Annex is organized in 5 tasks according...

Visier, J. C.

2004-01-01T23:59:59.000Z

246

Science Summary  

NLE Websites -- All DOE Office Websites (Extended Search)

BL6-2C BL9-3 BL10-2 Share this Article Laboratree Ologeez SciLink LabSpaces Imaging Mercury in the Rhizosphere of Wetland Plants summary written by Raven Hanna High levels of...

247

Science Summary  

NLE Websites -- All DOE Office Websites (Extended Search)

Press Release Share this Article Laboratree Ologeez SciLink LabSpaces Reducing Fuel Cell Costs by Changing the Structure and Reactivity of Platinum summary written by Raven...

248

Building America Expert Meeting: Summary for Diagnostic and Performanc...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Building HVAC Systems Energy Savings Potential and RD&D Opportunities for Commercial Building HVAC Guidelines on Airflow and Refrigerant Charge Verification and Diagnostics...

249

HVAC Right-Sizing Part 1: Calculating Loads  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Building America Building America Presented by: Mike Gestwick - National Renewable Energy Laboratory Arlan Burdick, Anthony Grisolia - IBACOS, a Building America Research Team HVAC Right-Sizing Part 1: Calculating Loads Thursday, April 28 11:00 a.m. - 12:00 p.m. Eastern Building Technologies Program Mike Gestwick michael.gestwick@nrel.gov Building America: Introduction April 28, 2011 Introduction to Building America * Reduce energy use in new and existing residential buildings * Promote building science and systems engineering / integration approach * "Do no harm": Ensure safety, health and durability are maintained or improved * Accelerate adoption of high performance technologies www.buildingamerica.gov 15 Industry Research Teams Habitat Cost Effective Energy Retrofit Program

250

Fight Fall Allergies and Save Energy by Checking Your HVAC System |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Fight Fall Allergies and Save Energy by Checking Your HVAC System Fight Fall Allergies and Save Energy by Checking Your HVAC System Fight Fall Allergies and Save Energy by Checking Your HVAC System October 15, 2012 - 3:19pm Addthis Change your furnace filter to help keep allergies at bay and keep your furnace and air conditioner running efficiently. | Photo courtesy of ©iStockphoto.com/JaniceRichard. Change your furnace filter to help keep allergies at bay and keep your furnace and air conditioner running efficiently. | Photo courtesy of ©iStockphoto.com/JaniceRichard. Elizabeth Spencer Communicator, National Renewable Energy Laboratory What does this mean for me? Change your furnace filters every month or two to keep your HVAC equipment operating efficiently. I have unbelievably horrible fall allergies. I've never figured out what

251

Total and Peak Energy Consumption Minimization of Building HVAC Systems Using Model Predictive Control  

E-Print Network (OSTI)

inputs. The idea of modeling building thermal behavior usingThe detail of building thermal modeling is pre- sented in [Modeling and optimal control algorithm design for hvac systems in energy efficient buildings,’’

Maasoumy, Mehdi; Sangiovanni-Vincentelli, Alberto

2012-01-01T23:59:59.000Z

252

What are the Best HVAC Solutions for Low-Load, High Performance Homes?"  

Energy.gov (U.S. Department of Energy (DOE))

This presentation was given at the Summer 2012 DOE Building America meeting on July 26, 2012, and addressed the question What are the best HVAC solutions for low-load, high performance homes?"

253

Building America Webinar: HVAC Right-Sizing Part 1—Calculating Loads  

Energy.gov (U.S. Department of Energy (DOE))

During this webinar, Building America Research Team IBACOS highlighted the key criteria required to create accurate heating and cooling load calculations. Current industry rules of thumb, perceptions and barriers to right-sizing HVAC were also discussed.

254

HVAC system optimization with CO2 concentration control using genetic algorithms  

Science Journals Connector (OSTI)

This study describes the use of genetic algorithms (GAs) for operating standard HVAC systems (HVAC—heating, ventilation and air conditioning) in order to optimize performance, primarily with regard to power saving. Genetic algorithms were introduced as an instrument for solving optimization problems. Analytic optimization procedures are widely used in other fields of engineering, but they are difficult to operate within HVAC systems, because the range of the research is usually too broad, the problems are not linear but rather discontinuous, and they mostly have complex limitations. This is why for this type of system genetic algorithms are used, since they have the qualities of robustness and efficiency that are crucial for finding the optimal solution. A simulation is conducted in order to demonstrate how much power can be saved by using the suggested method of CO2 concentration control in a standard HVAC system. In addition to Matlab Simulink, the suggested method is verified with Energy software.

Velimir Congradac; Filip Kulic

2009-01-01T23:59:59.000Z

255

Analysis of the HVAC System at the Willow Branch Intermediate School  

E-Print Network (OSTI)

This report presents an analysis of the HVAC system at the Willow Branch Intermediate School for the MEEN 685 class project. The school is located at College Station, Texas. A portion of the school belonged to Oakwood Intermediate School which...

Wei, G.

1997-01-01T23:59:59.000Z

256

Application of Various HVAC Simulation Programs and Visual Tools to Commissioning  

E-Print Network (OSTI)

Various existing HVAC system simulation programs and visualization tools are considered to be potentially powerful tools for commissioning. Although not originally developed as commissioning tools, these programs facilitate the confirmation...

Zheng, M.; Pan, S.

2007-01-01T23:59:59.000Z

257

Computational Study on Thermal Properties of HVAC System with Building Structure Thermal Storage  

E-Print Network (OSTI)

Building structure thermal storage (BSTS) HVAC systems can store heat during nighttime thermal storage operation (nighttime operation hours) by using off-peak electricity and release it in the daytime air-conditioning operation (daytime operation...

Sato, Y.; Sagara, N.; Ryu, Y.; Maehara, K.; Nagai, T.

2007-01-01T23:59:59.000Z

258

DOE Convening Report on Certification of Commercial HVAC and CRE Products  

Energy.gov (U.S. Department of Energy (DOE))

This document is the convening report on the feasibility of a negotiated rulemaking to revise the certification program for commercial HVAC and CRE products published on October 2, 2012.

259

Energy Savings Potential and RD&D Opportunities for Commercial Building HVAC  

Energy.gov (U.S. Department of Energy (DOE))

This Building Technologies Office report assesses heating, ventilation, and air-conditioning (HVAC) technologies for U.S. commercial buildings to identify and provide analysis on 17 priority technology options in various stages of development.

260

Requirements for Commissioning HVAC Systems Using BEMS and Commissioning the BEMS Itself Based on Questionnaire Surveys  

E-Print Network (OSTI)

In this paper the present status and requirements for commissioning of HVAC Systems using Building Energy Management Systems (BEMS) and commissioning the BEMS itself are investigated and summarized. The information presented is based on the results...

Yoshida, H.; Vaezi-Nejad, H.; Choiniere, D.; Wang, F.

2004-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hvac zone summary" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Development of HVAC System Performance Criteria Using Factorial Design and DOE-2 Simulation  

E-Print Network (OSTI)

A new approach is described for the development of Heating, Ventilating, and Air-conditioning (HVAC) System Performance Criteria for the Texas Building Energy Design Standard. This approach integrates a design of experimental methodology and DOE-2...

Hou, D.; Jones, J. W.; Hunn, B. D.; Banks, J. A.

1996-01-01T23:59:59.000Z

262

A Qualitive Modeling Approach for Fault Detection and Diagnosis on HVAC Systems  

E-Print Network (OSTI)

This paper describes the basics and first test results of a model based approach using qualitative modeling to perform Fault Detection and Diagnostics (FDD) on HVAC and R systems. A quantized system describing the qualitative behavior of a...

Muller, T.; Rehault, N.; Rist, T.

2013-01-01T23:59:59.000Z

263

Energy Savings Potential and RD&D Opportunities for Residential Building HVAC Systems  

Energy.gov (U.S. Department of Energy (DOE))

This report assesses 135 different heating, ventilation, and air-conditioning (HVAC) technologies for U.S. residential buildings to identify and provide analysis on 19 priority technology options in various stages of development.

264

Building America Whole-House Solutions for Existing Homes: Inverted Attic Bulkhead for HVAC Ductwork  

Energy.gov (U.S. Department of Energy (DOE))

This occupied test home received a modified truss system to accommodate ductwork within an inverted insulated bulkhead along the attic floor, which saves energy by placing heating, ventilating, and air-conditioning (HVAC) ductwork within the home's thermal boundary.

265

Energynet Summary  

NLE Websites -- All DOE Office Websites (Extended Search)

Project Summary Project Summary HELP Index Summary Scenario Reference Student Pages Subject/Content Area: Physical science/electricity, geometry and applied mathematics Target Audience: Middle school level - all students including gifted, learning-disabled, behavior-disordered and limited English proficient Project Goals: As a result of their participation in the Activating the EnergyNet project, the students will develop the abilities necessary to do scientific inquiry. They will increase their understanding of factors affecting energy cost and consumption, including the impact of energy production on the environment and the available technology and conversion costs. Students will use problem-solving strategies to design and implement interventions, assess the outcome, share data and strategies with other schools, and present

266

DOE Convening Report on Certification of Commercial HVAC and CRE Products  

NLE Websites -- All DOE Office Websites (Extended Search)

Convening Report on Certification of Commercial HVAC and CRE Products, October 2, 2012 Convening Report on Certification of Commercial HVAC and CRE Products, October 2, 2012 1 U.S. DEPARTMENT OF ENERGY CONVENING REPORT ON THE FEASIBILITY OF A NEGOTIATED RULEMAKING TO REVISE THE CERTIFICATION PROGRAM FOR COMMERCIAL HEATING, VENTILATING AIR CONDITIONING AND COMMERCIAL REFRIGERATION EQUIPMENT October 2, 2012 Alan W. Strasser, Esq., MA Convener

267

A Unified and Integrated Energy Management System for HVAC Spaces and Power House  

E-Print Network (OSTI)

A UNIFIED AND INTEGRATED ENERGY MANAGEMENT SYSTEM FOR HVAC SPACES AND POWER HOUSE A.Kaya The University of Akron Mechanical Engineering Akron,OH 44325 ABSTRACT This paper describes a totally integrated energy management system throughout... the plant and facilities. The equipment involves: the power flant (boilers, cogeneration turbines, chillers); HVAC 0 buildings; air handling and other distribution systems. The energy management system has the architecture for data transmission...

Kaya, A.; Debban, G. D.

268

Case study field evaluation of a systems approach to retrofitting a residential HVAC system  

SciTech Connect

This case study focusing on a residence in northern California was undertaken as a demonstration of the potential of a systems approach to HVAC retrofits. The systems approach means that other retrofits that can affect the HVAC system are also considered. For example, added building envelope insulation reduces building loads so that smaller capacity HVAC system can be used. Secondly, we wanted to examine the practical issues and interactions with contractors and code officials required to accomplish the systems approach because it represents a departure from current practice. We identified problems in the processes of communication and installation of the retrofit that led to compromises in the final energy efficiency of the HVAC system. These issues must be overcome in order for HVAC retrofits to deliver the increased performance that they promise. The experience gained in this case study was used to optimize best practices guidelines for contractors (Walker 2003) that include building diagnostics and checklists as tools to assist in ensuring the energy efficiency of ''house as a system'' HVAC retrofits. The best practices guidelines proved to be an excellent tool for evaluating the eight existing homes in this study, and we received positive feedback from many potential users who reviewed and used them. In addition, we were able to substantially improve the energy efficiency of the retrofitted case study house by adding envelope insulation, a more efficient furnace and air conditioner, an economizer and by reducing duct leakage.

Walker, Iain S.; McWiliams, Jennifer A.; Konopacki, Steven J.

2003-09-01T23:59:59.000Z

269

Improving the Efficiency of Light-Duty Vehicle HVAC Systems using Zonal Thermoelectric Devices and Comfort Modeling  

Energy.gov (U.S. Department of Energy (DOE))

Summarizes results from a study to identify and demonstrate technical and commercial approaches necessary to accelerate the deployment of zonal TE HVAC systems in light-duty vehicles

270

Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage  

E-Print Network (OSTI)

1980, but its thermal solar and storage systems received achiller. A 30 m heat storage tank solar decouples heatfacility with thermal storage and solar- assisted HVAC for

Mammoli, Andrea

2014-01-01T23:59:59.000Z

271

A plug and play framework for an HVAC air handling unit and temperature sensor auto recognition technique.  

E-Print Network (OSTI)

??A plug and play framework for an HVAC air handling unit control system is proposed in this study. This is the foundation and the first… (more)

Zhou, Xiaohui

2010-01-01T23:59:59.000Z

272

Demand Response-Enabled Model Predictive HVAC Load Control in Buildings using Real-Time Electricity Pricing.  

E-Print Network (OSTI)

??A practical cost and energy efficient model predictive control (MPC) strategy is proposed for HVAC load control under dynamic real-time electricity pricing. The MPC strategy… (more)

Avci, Mesut

2013-01-01T23:59:59.000Z

273

System dynamics based models for selecting HVAC systems for office buildings: a life cycle assessment from carbon emissions perspective.  

E-Print Network (OSTI)

??This study aims to explore the life cycle environmental impacts of typical heating ventilation and air condition (HVAC) systems including variable air volume (VAV) system,… (more)

Chen, S

2011-01-01T23:59:59.000Z

274

Optimized Fan Control In Variable Air Volume HVAC Systems Using Static Pressure Resets: Strategy Selection and Savings Analysis.  

E-Print Network (OSTI)

??The potential of static pressure reset (SPR) control to save fan energy in variable air volume HVAC systems has been well documented. Current research has… (more)

Kimla, John

2010-01-01T23:59:59.000Z

275

Executive Summary  

NLE Websites -- All DOE Office Websites (Extended Search)

Executive Summary Executive Summary Highway-based excise taxes are paid by highway users, and the tax revenues are distributed to States for supporting highways, safety, and transit programs. The processes for collecting these taxes and redistributing them to the States are very complex. The U.S. Treasury collects most of the taxes from a relatively small number of large corporations located in only a few States. The Internal Revenue Service (IRS) does not have an accurate picture of where the motor fuel is eventually consumed. Because the actual State-by-State contributions are not available, detailed analyses are required to estimate a State's on-highway motor fuel use. The attribution process uses State-reported data and nationally applied statistical models to determine how much fuel is used on highways in each State and the proportion of each State's usage in comparison to the total motor fuel usage for all States.

276

EXECUTIVE SUMMARY  

National Nuclear Security Administration (NNSA)

FUSION ENERGY SCIENCE ADVISORY COMMITTEE FUSION ENERGY SCIENCE ADVISORY COMMITTEE Panel on High Energy Density Laboratory Plasmas ADVANCING THE SCIENCE OF HIGH ENERGY DENSITY LABORATORY PLASMAS January 2009 UNITED STATES DEPARTMENT OF ENERGY 1 TABLE OF CONTENTS EXECUTIVE SUMMARY.......................................................................................... 5 1 HIGH ENERGY DENSITY LABORATORY PLASMA SCIENCE .................................... 15 2 THE CHARGE TO FESAC ...................................................................................... 19 3 THE PANEL PROCESS ............................................................................................ 20 4 STEWARDSHIP OF THE JOINT PROGRAM ............................................................... 23

277

McHugh Energy Consultants HVAC Trajectories toward Zero  

E-Print Network (OSTI)

#12;California Climate Zones 6 Coast: CZ's 1, 3, 5, 6, 7 Near Coast CZ's 2, 4, 8, 9 Inland Empire CZ) Occupant Controlled Smart Thermostat as a tradeoff against the solar ready zone #12;2013 Title 24 with an economizer and Mechanical cooling capacity >= 54,000 Btuh Applies to: Packaged DX rooftops Split

California at Davis, University of

278

Evaluation of flow capture techniques for measuring HVAC grilleairflows  

SciTech Connect

This paper discusses the accuracy of commercially available flow hoods for residential applications. Results of laboratory and field tests indicate these hoods can be inadequate to measure airflows in residential systems, and there can be large measurement discrepancies between different flow hoods. The errors are due to poor calibrations, sensitivity of the hoods to grille airflow non-uniformities, and flow changes from added flow resistance. It is possible to obtain reasonable results using some flow hoods if the field tests are carefully done, the grilles are appropriate, and grille location does not restrict flow hood placement. We also evaluated several simple flow capture techniques for measuring grille airflows that could be adopted by the HVAC industry and homeowners as simple diagnostics. These simple techniques can be as accurate as commercially available devices. Our test results also show that current calibration procedures for flow hoods do not account for field application problems. As a result, agencies such as ASHRAE or ASTM need to develop a new standard for flow hood calibration, along with a new measurement standard to address field use of flow capture techniques.

Walker, Iain S.; Wray, Craig P.

2002-11-01T23:59:59.000Z

279

Deposition of biological aerosols on HVAC heat exchangers  

SciTech Connect

Many biologically active materials are transported as bioaerosols 1-10 {micro}m in diameter. These particles can deposit on cooling and heating coils and lead to serious indoor air quality problems. This paper investigates several of the mechanisms that lead to aerosol deposition on fin and tube heat exchangers. A model has been developed that incorporates the effects of several deposition mechanisms, including impaction, Brownian and turbulent diffusion, turbophoresis, thermophoresis, diffusiophoresis, and gravitational settling. The model is applied to a typical range of air velocities that are found in commercial and residential HVAC systems 1 - 6 m/s (200 - 1200 ft/min), particle diameters from 1 - 8 {micro}m, and fin spacings from 3.2 - 7.9 fins/cm (8 - 16 fins/inch or FPI). The results from the model are compared to results from an experimental apparatus that directly measures deposition on a 4.7 fins/cm (12 FPI) coil. The model agrees reasonably well with this measured data and suggests that cooling coils are an important sink for biological aerosols and consequently a potential source of indoor air quality problems.

Siegel, Jeffrey; Walker, Ian

2001-09-01T23:59:59.000Z

280

A new modelling methodology to control HVAC systems  

Science Journals Connector (OSTI)

Thermal comfort plays an important role in any working environment, but it is a very vague term and it is also very difficult to represent it on modern computers. Its proper definition could be a condition of the mind which expresses satisfaction with the thermal environment and, therefore, it depends on the individual’s physiology and psychology. Several researchers have investigated the relationships between room conditions and thermal comfort. Generally speaking, statistical approaches had been used whereas fuzzy and neural approaches have been recently proposed. In this work it is proposed a new thermal comfort model based on the P.O. Fanger PMV index according to the Institute of the University of Kansas and it has been adapted to a specific indoor ambience with a thermal comfort logger. The results showed that this methodology puts forward an adequate accuracy and suggests temperatures according to the present HVAC standards and those adaptive models show adequate values for thermal neutralities even though they are not suitable for energy saving due to its static value on a daily basis.

José A. Orosa

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hvac zone summary" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Outdoor airflow into HVAC systems: An evaluation of measurement technologies  

SciTech Connect

During the last few years, new technologies have been introduced for measuring the flow rates of outdoor air (OA) into HVAC systems; however, an evaluation of these measurement technologies has not previously been published. This document describes a test system and protocols developed for controlled evaluation of these measurement technologies. The results of tests of three measurement technologies are also summarized. The test system and protocol were judged practical and very useful. The test results indicate that one measurement technology can measure OA flow rates with errors of 20% or less without a field-based calibration, as long as the OA velocities are sufficient to provide an accurately measurable pressure signal. The test results for a second measurement technology are similar; however, a difficult field-based calibration relating the OA flow rate with the pressure signal would be required to reduce errors below approximately 30%. The errors in OA flow rates measured with the third measurement technology, that uses six electronic airspeed sensors downstream of the OA inlet louver, exceeded 100%; however, these errors could be substantially reduced through a difficult field based calibration. The effects of wind on the accuracy of these measurement technologies still needs to be evaluated.

Fisk, William J.; Faulkner, David; Sullivan, Douglas P.; Delp, Woody

2003-09-01T23:59:59.000Z

282

Compression effects on pressure loss in flexible HVAC ducts  

SciTech Connect

A study was conducted to evaluate the effect of compression on pressure drop in flexible, spiral wire helix core ducts used in residential and light commercial applications. Ducts of 6 inches, 8 inches and 10 inches (150, 200 and 250 mm) nominal diameters were tested under different compression configurations following ASHRAE Standard 120-1999--Methods of Testing to Determine Flow Resistance of HVAC Air Ducts and Fittings. The results showed that the available published references tend to underestimate the effects of compression. The study demonstrated that moderate compression in flexible ducts, typical of that often seen in field installations, could increase the pressure drop by a factor of four, while further compression could increase the pressure drop by factors close to ten. The results proved that the pressure drop correction factor for compressed ducts cannot be independent of the duct size, as suggested by ASHRAE Fundamentals, and therefore a new relationship was developed for better quantification of the pressure drop in flexible ducts. This study also suggests potential improvements to ASHRAE Standard 120-1999 and provides new data for duct design.

Abushakra, Bass; Walker, Iain S.; Sherman, Max H.

2002-07-01T23:59:59.000Z

283

Evaluation of HVAC filters as a sampling mechanism for indoor microbial communities  

Science Journals Connector (OSTI)

HVAC filters are in place for extended periods of time and can serve as integrated air samplers. This paper presents a comparison of bacterial and fungal concentrations and communities in HVAC filter dust and other sampling locations in occupied residences and in the unoccupied \\{UTest\\} House. A DNA-based, culture-independent approach was utilized to characterize the microbial communities. Microbial concentrations and communities in HVAC filter dust samples were not statistically different from those in high surface dust samples in occupied homes. Despite the general similarity in the communities, Proteobacteria were present in greater proportion in HVAC filter dust samples than in surface dust samples suggesting the air origin of this phylum. Gram-positive bacteria were present in greater proportion in occupied residences than in an unoccupied test house, confirming the potential association of this group with occupants. HVAC filter microbial communities were not different from those present in a composited month-long indoor air sample providing preliminary evidence that filters could be a viable option for long-term investigation of airborne biological contaminants.

Federico Noris; Jeffrey A. Siegel; Kerry A. Kinney

2011-01-01T23:59:59.000Z

284

Executive Summary  

NLE Websites -- All DOE Office Websites (Extended Search)

Worker Safety and Health Program LBNL/PUB-3851, Rev. 2.2 (March 2012) Worker Safety and Health Program LBNL/PUB-3851, Rev. 2.2 (March 2012) Worker Safety and Health Program Lawrence Berkeley National Laboratory LBNL Worker Safety and Health Program LBNL/PUB-3851, Rev. 2.2 (March 2012) This page intentionally left blank. LBNL Worker Safety and Health Program LBNL/PUB-3851, Rev. 2.2 (March 2012) i Contents Executive Summary .............................................................................................. v 1. Introduction................................................................................................... 1 1.1 Work Activities .............................................................................................. 1

285

High-Speed Internet Access via HVAC Ducts: A New Approach Daniel D. Stancil, Ozan K. Tonguz, Ariton Xhafa, Ahmet Cepni, and Pavel Nikitin  

E-Print Network (OSTI)

High-Speed Internet Access via HVAC Ducts: A New Approach Daniel D. Stancil, Ozan K. Tonguz, Ariton conditioning (HVAC) ducts for indoor wireless transmission systems and networks. Mea- surements and system to 100 Mbps should be possible, when HVAC system is used in con- junction with OFDM technology. Keywords

Stancil, Daniel D.

286

This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)  

E-Print Network (OSTI)

at Oklahoma State University (www.hvac.okstate.edu) The correct citation for the paper is: Rees, S.J., J cooling loads is of critical concern to designers of HVAC systems. The work reported here has been carried of the HVAC industry worldwide would be improved if common methods of performing key design calculations were

Ghajar, Afshin J.

287

Cooperative Control of Air Flow for HVAC Systems Shuai Liu1,2, Yushen Long1, Lihua Xie1 and Alexandre M. Bayen3  

E-Print Network (OSTI)

Cooperative Control of Air Flow for HVAC Systems Shuai Liu1,2, Yushen Long1, Lihua Xie1 for building heating, ven- tilation and air-conditioning (HVAC) systems. The strategy consists in two level and the HVAC system parameters. I. INTRODUCTION In recent years, energy saving and environment protection have

288

Logue and Singer, HVAC&R, 20(2): 264-275, 2014. Energy Impacts of Effective Residential Range Hood Use, LBNL-6683E Page 1  

E-Print Network (OSTI)

Logue and Singer, HVAC&R, 20(2): 264-275, 2014. Energy Impacts of Effective Residential Range Hood and Singer, HVAC&R, 20(2): 264-275, 2014. Energy Impacts of Effective Residential Range Hood Use, LBNL-6683E Laboratory is an equal opportunity employer. #12;Logue and Singer, HVAC&R, 20(2): 264-275, 2014. Energy

289

IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, VOL. 51, NO. 5, MAY 2003 945 Propagation Model for the HVAC Duct as a  

E-Print Network (OSTI)

for the HVAC Duct as a Communication Channel Pavel V. Nikitin, Member, IEEE, Daniel D. Stancil, Senior Member (HVAC) ducts in buildings are typically hollow metal pipes which can be used as waveguides to carry such a communication system. This paper presents a propagation model for a straight HVAC duct terminated at both ends

Stancil, Daniel D.

290

A Simple Path Loss Prediction Model for HVAC Systems O. K. Tonguz, D. D. Stancil, A. E. Xhafa, A. G. Cepni, P. V. Nikitin  

E-Print Network (OSTI)

1 A Simple Path Loss Prediction Model for HVAC Systems O. K. Tonguz, D. D. Stancil, A. E. Xhafa, A, and air conditioning (HVAC) cylindrical ducts in 2.4-2.5 GHz frequency band. The model we propose predicts the average power loss between a transmitter-receiver pair in an HVAC duct network. This prediction model

Stancil, Daniel D.

291

Critical Question #4: What are the Best Off-the-Shelf HVAC Solutions for  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Critical Question #4: What are the Best Off-the-Shelf HVAC Critical Question #4: What are the Best Off-the-Shelf HVAC Solutions for Low-Load, High-Performance Homes and Apartments? Critical Question #4: What are the Best Off-the-Shelf HVAC Solutions for Low-Load, High-Performance Homes and Apartments? What is currently in the market? What are the limitations of these systems? What are the desired specifications for these systems? What are the realistic space conditioning loads of these high-performance homes and apartments? cq4_forced_air_systems_walker.pdf cq4_simplified_space_cond_prahl.pdf cq4_ground_heat_exchanger_im.pdf More Documents & Publications Track C - Market-Driven Research Solutions Track B - Critical Guidance for Peak Performance Homes Energy Storage & Power Electronics 2008 Peer Review - Power Electronics

292

HVAC vs. Space Heaters: Which is More Efficient? | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? January 10, 2011 - 4:27pm Addthis Andrea Spikes Communicator at DOE's National Renewable Energy Laboratory I live in Colorado, and when it's cold it is very, very cold. Since I hate paying high heating bills, I typically have my thermostat set to a chilly 62°F. My husband and I have gotten used to this, and really like being able to use a warm comforter while the air stays cooler. There are some nights, however, that even this setting seems too high and the heater is running a lot more than I'd like it to. When it's below 0° overnight, or even sometimes during the day, we occasionally break out our oil-filled space heater when we're only using one room. That has me

293

HVAC vs. Space Heaters: Which is More Efficient? | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? January 10, 2011 - 4:27pm Addthis Andrea Spikes Communicator at DOE's National Renewable Energy Laboratory I live in Colorado, and when it's cold it is very, very cold. Since I hate paying high heating bills, I typically have my thermostat set to a chilly 62°F. My husband and I have gotten used to this, and really like being able to use a warm comforter while the air stays cooler. There are some nights, however, that even this setting seems too high and the heater is running a lot more than I'd like it to. When it's below 0° overnight, or even sometimes during the day, we occasionally break out our oil-filled space heater when we're only using one room. That has me

294

Multi-objective optimization of HVAC system with an evolutionary computation algorithm  

Science Journals Connector (OSTI)

A data-mining approach for the optimization of a HVAC (heating, ventilation, and air conditioning) system is presented. A predictive model of the HVAC system is derived by data-mining algorithms, using a dataset collected from an experiment conducted at a research facility. To minimize the energy while maintaining the corresponding IAQ (indoor air quality) within a user-defined range, a multi-objective optimization model is developed. The solutions of this model are set points of the control system derived with an evolutionary computation algorithm. The controllable input variables — supply air temperature and supply air duct static pressure set points — are generated to reduce the energy use. The results produced by the evolutionary computation algorithm show that the control strategy saves energy by optimizing operations of an HVAC system.

Andrew Kusiak; Fan Tang; Guanglin Xu

2011-01-01T23:59:59.000Z

295

Survival of bioaerosols in HVAC system photocatalytic filters  

Science Journals Connector (OSTI)

Abstract The survival of an experimental bioaerosol in photocatalytic and non-photocatalytic filters was investigated under UV-A or UV-C radiation exposure. To ensure the generation of reproducible bioaerosols in real operating conditions of Heating, Ventilation and Air Conditioning (HVAC) systems and their homogeneous coating on filters, a reactor with an optimal geometry was developed. The bacterial aerosol was generated from standardised bacterial suspensions and the Gram-negative bacterial model Escherichia coli was used as the experimental organism. The bioaerosol was characterised in terms of particle size distribution, reproducibility and stability over time. The coating of aerosolised cells on the filters was then studied. The total number of aerosolised E. coli cells was different from the amount of cultivable bacterial cells extracted from filters, probably resulting from the stress of the aerosolisation process. Damages to the outer membrane of E. coli cells were clearly observed through SEM and epifluorescent microscopy analysis. The influence of important physical parameters in the reactor-aerosolisation duration, frontal velocity and relative humidity- on the amount of aerosolised cells coated on filters were also investigated. Finally, the effects of UV-A or UV-C radiation were assessed on aerosolised microorganisms coated on HEPA photocatalytic filters and on photocatalytic or non-photocatalytic filters containing activated charcoal. The HEPA photocatalytic filters demonstrated a better disinfection efficiency with full damages of the aerosolised bacterial cells, probably resulting from an optimal contact between TiO2 coating and the microorganisms. In contrast, the use of filters with activated charcoal resulted in the apparition of an inactivation threshold that could be attributed to the penetration of aerosolised cells within the activated charcoal layer and the absence of contact with the photocatalyst. However, UV-C photocatalysis was able to inactivate faster and, at the same time, mineralise biological pollutants than UV-A.

S. Pigeot-Remy; J.C. Lazzaroni; F. Simonet; P. Petinga; C. Vallet; P. Petit; P.J. Vialle; C. Guillard

2014-01-01T23:59:59.000Z

296

Science Summary  

NLE Websites -- All DOE Office Websites (Extended Search)

July 30, 2009 July 30, 2009 » Links Scientific Highlight Center for Advanced Molecular Photovoltaics, Stanford University » Share this Article Laboratree Ologeez SciLink LabSpaces Molecular Mixing in Organic Solar Cells summary written by Raven Hanna Solar panels contain a number of solar cells that convert light into electricity. Solar cells are traditionally made of crystalline silicon, which presently have 15-20% efficiency in conversion of light into electricity. However, these traditional cells are bulky and have high production costs that can take 5-7 years of solar panel operation to recover. Using solar cells made from organic materials could lower their production costs. This would lessen the time it takes for solar panels to generate more energy than consumed during production and would also result

297

Science Summary  

NLE Websites -- All DOE Office Websites (Extended Search)

pseudogap image pseudogap image » Links Scientific Highlight SIMES Shen Lab SLAC Today Article » Share this Article Laboratree Ologeez SciLink LabSpaces Scientists Find Unexpected Electron Behavior in the Pseudogap of High-temperature Superconductors summary written by Raven Hanna Superconductivity is a hot topic in physics for good reason. With an electrical resistance of zero, superconductors transport electrical current with no loss of energy. Unfortunately, scientists have only found materials to be superconducting at very low temperatures, much too low for widespread use. In the 1980s, scientists discovered a class of "high-temperature" superconductors that can be used at the temperature of liquid nitrogen (~-200°C). This discovery has raised scientists' hopes that materials may

298

EXECUTIVE SUMMARY  

NLE Websites -- All DOE Office Websites (Extended Search)

EXECUTIVE SUMMARY This document contains an assessment of the first project to be completed under the U.S. Department of Energy Clean Coal Technology Program. The project was selected under Round I and is known officially as "The Demonstration of an Advanced Cyclone Coal Combustor, with Internal Sulfur, Nitrogen, and Ash Control for the Conversion of a 23 MMBtu/hour Oil-Fired Boiler to Pulverized Coal." The project was carried out by the Coal Tech Corporation over the period March 1987 February 1991 at the site of the Keeler/Dorr-Oliver Boiler Company in Williamsport, Pennsylvania. The project was a three-year demonstration scale test of a 30 MMBtu/hr air-cooled ceramic slagging cyclone combustor retrofitted to a horizontal 23-MMBtu/hr oil or natural gas-fired Keeler/Dorr-Oliver DS-9

299

Science Summary  

NLE Websites -- All DOE Office Websites (Extended Search)

Hasan Research Hasan Research Princeton News Release » Share this Article Laboratree Ologeez SciLink LabSpaces Macroscopic Quantum Insulator State Observed summary written by Raven Hanna One of the strangest consequences of quantum mechanics is the seemingly instantaneous communication of subatomic particles over long distances. Known as quantum entanglement, pairs or groups of particles can become linked so that any changes made to one will cause the others to respond quicker than the time it takes for light to travel between them. Scientists are interested in finding a material that shows quantum entanglement on a macroscopic scale but which is neither a superconductor nor a superfluid. Dubbed a topological insulator, this theorized, exotic state of matter would have unusual conducting properties. For example,

300

Science Summary  

NLE Websites -- All DOE Office Websites (Extended Search)

03, 2008 03, 2008 » Links Scientific Highlight Tainer Website Scripps Press Release » Share this Article Laboratree Ologeez SciLink LabSpaces Role of Specific Protein Mutations in Causing Human Disease Revealed summary written by Brad Plummer, SLAC Communication Office Scientists are one step closer to understanding a piece of the machinery involved in DNA transcription and repair, thanks to work done in part at the SSRL macromolecular crystallography Beam Line 11-1. The team, led by The Scripps Research Institute researcher John Tainer, and colleagues worked out the structure of an important enzyme call XPD, a member of the helicase family of enzymes, found in all living organisms. The results were published in the May 2008 edition of the journal Cell. In eukaryotes, XPD is responsible for unwinding double-stranded DNA

Note: This page contains sample records for the topic "hvac zone summary" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Science Summary  

NLE Websites -- All DOE Office Websites (Extended Search)

February 25, 2010 February 25, 2010 seafloor_biofilms Image of pillow basalts from inside the Pisces Submersible. » Links Scientific Highlight Templeton Lab EMSL News Imaging at SSRL » Share this Article Laboratree Ologeez SciLink LabSpaces Researchers Discover an Unexpected Source of Energy for Deep-sea Microbial Communities summary written by Raven Hanna New rock formed by deep undersea volcanoes does not stay bare long. Microbes quickly move onto these basalts to form communities in the form of biofilms. As these biofilms grow and develop, they change the geology of their environment, forming mineral deposits. Since many of these communities are deep in the cold ocean waters, where sunlight does not reach, they must use alternative sources of energy. What these might be is unknown, but a common theory posits that the microbes may be obtaining

302

Science Summary  

NLE Websites -- All DOE Office Websites (Extended Search)

10 10 image Outside view of the T=4 subunit arrangement. » Links Scientific Highlight Johnson Lab » Share this Article Laboratree Ologeez SciLink LabSpaces Following the pH-dependent Conformational Changes of a Maturing Viral Capsid summary written by Raven Hanna The capsid that surrounds viruses is formed from subunit proteins that interact in specific ways to form a tight shell. The processes of coming together and forming interactions are multistep and complex and are fundamental events to acquire viral infectivity. The capsid maturation process of the Nudaurelia capensis omega virus includes pH-dependant conformational changes and auto-proteolysis. Like many human viruses such as HIV and herpes virus, NwV, an insect virus, requires these specific structural changes to become infectious.

303

Science Summary  

NLE Websites -- All DOE Office Websites (Extended Search)

25, 2008 25, 2008 » Links Scientific Highlight Saphire Website Scripps Press Release Tracking Ebola, Scripps At the Forefront » Share this Article Laboratree Ologeez SciLink LabSpaces Revealing a Structural Weakness of the Deadly Ebolavirus summary written by Brad Plummer, SLAC Communication Office Scientists are one step closer to conquering the deadly Ebolavirus, thanks to research conducted at SSRL structural biology Beam Lines 9-2 and 11-1 and ALS Beam Line 5.02 by a team of researchers led by Erica Ollmann Saphire from The Scripps Research Institute. The results were published in the July 10 edition of the journal Nature. Using macromolecular crystallography techniques, the team solved the structure of a protein on the Ebolavirus's surface, called glycoprotein GP,

304

E-Print Network 3.0 - active zone development Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

and Information Sciences 2 Technical Report Documentation Page 1. Report No. Summary: and developed recommendations for improvements of urban arterial work zone traffic...

305

E-Print Network 3.0 - accident zone osobennosti Sample Search...  

NLE Websites -- All DOE Office Websites (Extended Search)

Physics 2 A Technique for Showing Causal Arguments in Accident Reports C. W. Johnson; University of Glasgow; Glasgow, Scotland, UK Summary: and the work zone accident...

306

Student Zone  

NLE Websites -- All DOE Office Websites (Extended Search)

Student Zone Student Zone Homework Helpers All About Atoms - Learn about the parts of the atom! Virginia State Standards of Learning Practice Tests - Practice taking the SOL tests! Subjects currently include algebra, math, science and technology. Table of Elements - Basic physical and historical information about the elements! [Printable Version] Questions and Answers - Have a question? Need an answer? Check here first! Glossary of Science Terms - Definitions of some of the terms used on this site. Jefferson Lab Virtual Tour - How do scientists explore inside atoms? Video Resources Frostbite Theater - Short science experiments using liquid nitrogen, static electricity and more! Physics Out Loud - Jefferson Lab scientists and other experts explain some of the common words and terms used in nuclear physics research.

307

Part II: Project Summaries Project Summaries  

E-Print Network (OSTI)

Part II: Project Summaries Part II Project Summaries #12 generally cannot be achieved for reasonable computational cost. Applications that require modeling, and in nondestructive testing. The objective of this project is to advance the state of the art in electromagnetic

Perkins, Richard A.

308

Student FTE Summary Student FTE Summary  

E-Print Network (OSTI)

Student FTE Summary Fall 2010 #12;1 Student FTE Summary Fall Term 2010 Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Percentage of Student FTE by College. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Student FTE by Student Level

309

Pre-Commercial Demonstration of Cost-Effective Advanced HVAC Controls- 2014 BTO Peer Review  

Energy.gov (U.S. Department of Energy (DOE))

Presenter: Hayden Reeve, United Technologies Research Center Optimal control coordination of heating, ventilation, and air conditioning (HVAC) equipment can reduce energy by more than 20% over current building automation systems (BASs) but is not widely deployed due to challenges with complexity, scalability, and deployment.

310

2014-04-28 Issuance: Certification of Commercial HVAC, Water Heating, and Refrigeration Equipment; Final Rule  

Energy.gov (U.S. Department of Energy (DOE))

This document is a pre-publication Federal Register final rule regarding the certification of commercial heating, ventilation, and air-conditioning (HVAC), water heating (WH), and refrigeration (CRE) equipment, as issued by the Deputy Assistant Secretary for Energy Efficiency on April 28, 2014.

311

Estimates of HVAC filtration efficiency for fine and ultrafine particles of outdoor origin  

Science Journals Connector (OSTI)

Abstract This work uses 194 outdoor particle size distributions (PSDs) from the literature to estimate single-pass heating, ventilating, and air-conditioning (HVAC) filter removal efficiencies for PM2.5 and ultrafine particles (UFPs: HVAC filters identified in the literature. Filters included those with a minimum efficiency reporting value (MERV) of 5, 6, 7, 8, 10, 12, 14, and 16, as well as HEPA filters. We demonstrate that although the MERV metric defined in ASHRAE Standard 52.2 does not explicitly account for UFP or PM2.5 removal efficiency, estimates of filtration efficiency for both size fractions increased with increasing MERV. Our results also indicate that outdoor PSD characteristics and assumptions for particle density and typical size-resolved infiltration factors (in the absence of HVAC filtration) do not drastically impact estimates of HVAC filter removal efficiencies for PM2.5. The impact of these factors is greater for UFPs; however, they are also somewhat predictable. Despite these findings, our results also suggest that MERV alone cannot always be used to predict UFP or PM2.5 removal efficiency given the various size-resolved removal efficiencies of different makes and models, particularly for MERV 7 and MERV 12 filters. This information improves knowledge of how the MERV designation relates to PM2.5 and UFP removal efficiency for indoor particles of outdoor origin. Results can be used to simplify indoor air quality modeling efforts and inform standards and guidelines.

Parham Azimi; Dan Zhao; Brent Stephens

2014-01-01T23:59:59.000Z

312

IFC HVAC interface to EnergyPlus - A case of expanded interoperability for energy simulation  

SciTech Connect

Tedious manual input of data that define a building, its systems and its expected pattern of use and operating schedules for building energy performance simulation has in the past diverted time and resources from productive simulation runs. In addition to its previously released IFCtoIDF utility that semiautomates the import of building geometry, the new IFC HVAC interface to EnergyPlus (released at the end of 2003) makes it possible to import and export most of the data that define HVAC equipment and systems in a building directly from and to other IFC compatible software tools. This reduces the manual input of other data needed for successful simulation with EnergyPlus to a minimum. The main purpose of this new interface is to enable import of HVAC equipment and systems definitions, generated by other IFC compatible software tools (such as HVAC systems design tools) and data bases, into EnergyPlus, and to write such definitions contained in EnergyPlus input files to the original IFC files from which building geometry was extracted for the particular EnergyPlus input. In addition, this interface sets an example for developers of other software tools how to import and/or export data other than building geometry from and/or into EnergyPlus. This paper describes the necessary simplifications and shortcuts incorporated in this interface, its operating environment, interface architecture, and the basic conditions and methodology for its use with EnergyPlus.

Bazjanac, Vladimir; Maile, Tobias

2004-03-29T23:59:59.000Z

313

Building America Expert Meeting: Transitioning Traditional HVAC Contractors to Whole House Performance Contractors  

Energy.gov (U.S. Department of Energy (DOE))

This report outlines findings resulting from a U.S. Department of Energy Building America expert meeting held on March 29, 2011 by IBACOS to determine how HVAC companies can transition from a traditional contractor status to a service provider for whole house energy upgrade contracting.

314

Modeling and Measurement Constraints in Fault Diagnostics for HVAC Systems Massieh Najafi1  

E-Print Network (OSTI)

of the building's air conditioning units from reaching occupied spaces, so this unit's energy is simply wastedModeling and Measurement Constraints in Fault Diagnostics for HVAC Systems Massieh Najafi1 , David, Lawrence Berkeley National Laboratory, mdsohn@lbl.gov ABSTRACT Many studies have shown that energy savings

315

Particle loading rates for HVAC filters, heat exchangers, and ducts Nomenclature  

E-Print Network (OSTI)

Particle loading rates for HVAC filters, heat exchangers, and ducts Nomenclature Afl surface area of floor (m2 ) bf fraction of bypass flow around the filter (dimensionless) Cout outdoor concentration on the filter per volume of air (mg/lm m3 ) Mf,tot total mass deposited on the filter per month of operation (g

Siegel, Jeffrey

316

VOLUME 11, NUMBER 2 HVAC&R RESEARCH APRIL 2005 An Optimization-Based Approach for  

E-Print Network (OSTI)

of energy consumption, and human comfort requirements. This paper presents a daily energy management in view of rising energy costs, the government mandate on reduction of energy consumption (Capehart et al requirements. A major portion of energy consumption of a building comes from HVAC units. For example

Luh, Peter

317

Department of Energy and Mineral Engineering Spring 2013 Solar Innovations -HVAC and Waste Stream Analysis  

E-Print Network (OSTI)

included providing accurate floor plans and improve the system for improvement in indoor air qualityPENNSTATE Department of Energy and Mineral Engineering Spring 2013 Solar Innovations - HVAC areas and indoor air quality is below satisfactory. The waste stream was to be analysed to assess

Demirel, Melik C.

318

Webinar Summary Page 1  

NLE Websites -- All DOE Office Websites (Extended Search)

Webinar Summary Page 1 TC&WM EIS Webinar December 10, 2012 FINAL MEETING SUMMARY HANFORD ADVISORY BOARD WEBINAR: FINAL TANK CLOSURE AND WASTE MANAGEMENT ENVIRONMENTAL IMPACT...

319

A SUMMARY OF COAL IN THE COALMONT FORMATION (TERTIARY),  

E-Print Network (OSTI)

Chapter SN A SUMMARY OF COAL IN THE COALMONT FORMATION (TERTIARY), NORTH PARK BASIN, COLORADO By S assessment of selected Tertiary coal beds and zones in the Northern RockyMountains and Great Plains region, U Resource assessment of selected Tertiary coal beds and zones in the Northern Rocky Mountains and Great

320

Residential commissioning to assess envelope and HVAC system performance  

SciTech Connect

Houses do not perform optimally or even as many codes and forecasts predict. For example, Walker et al. (1998a) found large variations in thermal distribution system efficiency, as much as a factor of two even between side-by-side houses with the same system design and installation crew. This and other studies (e.g., Jump et al. 1996) indicate that duct leakage testing and sealing can readily achieve a 25 to 30% reduction in installed cooling capacity and energy consumption. As another example, consider that the building industry has recognized for at least 20 years the substantial impact that envelope airtightness has on thermal loads, energy use, comfort, and indoor air quality. However, Walker et al. (1998a) found 50% variances in airtightness for houses with the same design and construction crews, within the same subdivision. A substantial reason for these problems is that few houses are now built or retrofitted using formal design procedures, most are field assembled from a large number of components, and there is no consistent process to identify problems or to correct them. Solving the problems requires field performance evaluations of houses using appropriate and agreed upon procedures. Many procedural elements already exist in a fragmented environment; some are ready now to be integrated into a new process called residential commissioning (Wray et al. 2000). For example, California's Title 24 energy code already provides some commissioning elements for evaluating the energy performance of new houses. A house consists of components and systems that need to be commissioned, such as building envelopes, air distribution systems, cooling equipment, heat pumps, combustion appliances, controls, and other electrical appliances. For simplicity and practicality, these components and systems are usually evaluated individually, but we need to bear in mind that many of them interact. Therefore, commissioning must not only identify the energy and non-energy benefits associated with improving the performance of a component, it must also indicate how individual components interact in the complete building system. For this paper, we limit our discussion to diagnostics in areas of particular concern with significant interactions: envelope and HVAC systems. These areas include insulation quality, windows, airtightness, envelope moisture, fan and duct system airflows, duct leakage, cooling equipment charge, and combustion appliance backdrafting with spillage. The remainder of this paper first describes what residential commissioning is, its characteristic elements, and how one might structure its process. Subsequent sections describe a consolidated set of practical diagnostics that the building industry can use now. Where possible, we also discuss the accuracy and usability of these diagnostics, based on recent laboratory work and field studies. We conclude by describing areas in need of research and development, such as practical field diagnostics for envelope thermal conductance and combustion safety. There are several potential benefits for builders, consumers, code officials, utilities, and energy planners of commissioning houses using a consistent set of validated methods. Builders and/or commissioning agents will be able to optimize system performance and reduce consumer costs associated with building energy use. Consumers will be more likely to get what they paid for and builders can show they delivered what was expected. Code officials will be better able to enforce existing and future energy codes. As energy reduction measures are more effectively incorporated into the housing stock, utilities and energy planners will benefit through greater confidence in predicting demand and greater assurance that demand reductions will actually occur. Performance improvements will also reduce emissions from electricity generating plants and residential combustion equipment. Research to characterize these benefits is underway.

Wray, Craig P.; Sherman, Max H.

2001-08-31T23:59:59.000Z

Note: This page contains sample records for the topic "hvac zone summary" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Archived Reference Climate Zone: 7 Duluth, Minnesota  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

322

Archived Reference Climate Zone: 8 Fairbanks, Alaska  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

323

Archived Reference Climate Zone: 7 Duluth, Minnesota  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

324

Archived Reference Climate Zone: 8 Fairbanks, Alaska  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

325

STEP Financial Incentives Summary  

Energy.gov (U.S. Department of Energy (DOE))

STEP Financial Incentives Summary, from the Tool Kit Framework: Small Town University Energy Program (STEP).

326

Building America Whole-House Solutions for New Homes: HVAC Design Strategy for a Hot-Humid Production Builder  

Energy.gov (U.S. Department of Energy (DOE))

In this project, BSC worked with the builder to develop a cost-effective design for moving the HVAC system into conditioned space and increase the energy performance of future production houses in anticipation of 2015 IECC codes.

327

Detection and diagnosis of faults and energy monitoring of HVAC systems with least-intrusive power analysis  

E-Print Network (OSTI)

Faults indicate degradation or sudden failure of equipment in a system. Widely existing in heating, ventilating, and air conditioning (HVAC) systems, faults always lead to inefficient energy consumption, undesirable indoor ...

Luo, Dong, 1966-

2001-01-01T23:59:59.000Z

328

Integrated Ice Storage/Sprinkler HVAC System Sharply Cuts Energy Costs and Air-Distribution First Costs  

E-Print Network (OSTI)

Integrated ice thermal storage/sprinkler HVAC systems developed and applied by the author in several commercial applications shift a major portion of electric utility demand to cheaper off-peak hours, while also reducing significantly the first cost...

Meckler, G.

1986-01-01T23:59:59.000Z

329

Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage  

E-Print Network (OSTI)

performance of a solar-thermal- assisted hvac system. Energyfor rows of fixed solar thermal collectors using flatassisted by a 232 m solar thermal array providing heat to a

Mammoli, Andrea

2014-01-01T23:59:59.000Z

330

Proceedings of Healthy Buildings 2009 Paper 680 Do forced air HVAC systems have a role in healthy homes?  

E-Print Network (OSTI)

Proceedings of Healthy Buildings 2009 Paper 680 Do forced air HVAC systems have a role in healthy-extreme weather conditions. #12;Proceedings of Healthy Buildings 2009 Paper 680 Thus, a central forced air

Siegel, Jeffrey

331

Proceedings of Healthy Buildings 2009 Paper 474 Impacts of HVAC Filtration on Air-Conditioner Energy Consumption in  

E-Print Network (OSTI)

Proceedings of Healthy Buildings 2009 Paper 474 Impacts of HVAC Filtration on Air efficiency filters (Points A, B, and C, respectively). #12;Proceedings of Healthy Buildings 2009 Paper 474

Siegel, Jeffrey

332

Optimized Fan Control In Variable Air Volume HVAC Systems Using Static Pressure Resets: Strategy Selection and Savings Analysis  

E-Print Network (OSTI)

The potential of static pressure reset (SPR) control to save fan energy in variable air volume HVAC systems has been well documented. Current research has focused on the creation of reset strategies depending on specific system features...

Kimla, John

2010-07-14T23:59:59.000Z

333

Air quality metrics and wireless technology to maximize the energy efficiency of HVAC in a working auditorium  

Science Journals Connector (OSTI)

Abstract HVAC is the single largest consumer of energy in commercial and residential buildings. Reducing its energy consumption without compromising occupants’ comfort would have environmental and financial benefits. A wireless testbed consisting of a retrofitted wireless Condensation Particle Counter (CPC), 25 wireless temperature sensors, 2 HVAC-embedded temperature and CO2 sensors, and a webcam was deployed in a working auditorium, to monitor the air quality, temperature, and occupancy of the room. The main objectives were to identify particle sources using the retrofitted CPC, map the temperature variability of the room and select an optimal sensor location for HVAC control using clustering algorithms, and examine possible energy savings by operating the HVAC only during periods of occupancy using calendar-based scheduling and air quality indicators as proxies of occupancy. All air quality metrics increased with higher occupancy rates, although HVAC-modes changes were also identified as a source for particle numbers. Operating the HVAC using calendar-based scheduling resulted in energy savings of between 8 and 79%, increasing if occupancy events were scheduled close together. Finally, CO2 was the strongest predictor of occupancy counts with an R2 of 0.62 (pfilters should be replaced.

Anna Leavey; Yong Fu; Mo Sha; Andrew Kutta; Chenyang Lu; Weining Wang; Bill Drake; Yixin Chen; Pratim Biswas

2014-01-01T23:59:59.000Z

334

The new standard’s HVAC background noise requirements and their implementation in building design  

Science Journals Connector (OSTI)

The new ANSI classroom standard recommends long?term steady?state background sound level limits of 35 dBA and 55 dBC. Since the HVAC system is typically a room’s dominant steady?state noise source it is usually reasonable to apply these limits to the design of the system assuming that other noise sources produce insignificant additions to the room’s long?term background noise environment. The recommended sound level limits are significantly lower than current industry standards and complying with them will increase system costs. School administrators architects and HVAC system designers should therefore be prepared for the changes. This paper summarizes equipment selection and system design guidelines that have been found to be necessary for ensuring compliance with the sound level limits.

2001-01-01T23:59:59.000Z

335

Post-Retrocommissioning HVAC Operations Monitoring Using Enterprise-Wide energy Management System  

E-Print Network (OSTI)

Post-retrocommissioning HVAC Operations Monitoring Using Enterprise-wide Energy Management System Narendra Amarnani Project Manager Brian Roberts Section Manager County of Los Angeles – ISD Los Angeles, California, USA Howard Choy... earned a graduate degree from Cal Poly University, Pomona. He is a Certified Energy Manager, a LEED® AP, and a Certified Energy Plan Examiner. Brian’s is the Section Manager of the Systems Section within Energy Management Division. His...

Amarnani, N.; Roberts, B.; Choy, H.

2007-01-01T23:59:59.000Z

336

Discussion of an Optimization Scheme for the Ground Source Heat Pump System of HVAC  

E-Print Network (OSTI)

ICEBO2006, Shenzhen, China Renewable Energy Resources and a Greener Future Vol.VIII-13-3 Discussion of an Optimization Scheme for the Ground Source Heat Pump System of HVAC Wei Mu Suilin Wang Shuyuan Pan Yongzheng Shi Master Student... the Jurisdiction of Beijing Municipality (BJE10016200511). REFERENCES [1]Rongguang Wang,Yufeng Zhang,Yang,Xiaotong Zheng. Study on Direct Use Of Geothermal Energy For Heating And Its Energy Efficency Effects [J]. ACTA ENERGIAE SOLARIS SINICA, 2002, 23...

Mu, W.; Wang, S.; Pan, S.; Shi, Y.

2006-01-01T23:59:59.000Z

337

Development of an energy evaluation methodology to make multiple predictions of the HVAC&R system energy demand for office buildings  

Science Journals Connector (OSTI)

Abstract HVAC&R systems are the most energy consuming building services, representing approximately half of the final energy use in the building sector. Despite their significant energy use, there is a lack of a consistent and homogeneous framework to efficiently guide research, mainly due to the complexity and variety of HVAC&R systems, but also to insufficient rigor in their energy analysis. Quantifying the energy consumption characteristics of HVAC&R system is complicated, because the energy savings provided by this system depend on various factors. This research evaluates energy consumption characteristics of HVAC&R systems, with the aim of establishing a common idea for the analysis of building energy efficiency. The objective of this study is to develop an energy evaluation methodology and a simple simulation program that may be used by engineers and designers to assess the effectiveness and economic benefits of HVAC&R systems. Our approach deals with the concept of HVAC&R system energy use aggregation levels that are composed of subsystems. To carry out a techno-economical estimation of HVAC&R systems considering different types of subsystems, the matrix combination analyzed, and a total of 960 HVAC&R systems can be implemented for a large-scale office building. The methodology of energy analysis that was carried out in this study highlights how to plan and design toward utilizing the most effective HVAC&R systems.

Jinkyun Cho; Seungho Shin; Jonghurn Kim; Hiki Hong

2014-01-01T23:59:59.000Z

338

Proposal for the award of a contract for the design, supply, installation and commissioning of an HVAC (Heating, Ventilation and Air Conditioning) system for Building 3862  

E-Print Network (OSTI)

Proposal for the award of a contract for the design, supply, installation and commissioning of an HVAC (Heating, Ventilation and Air Conditioning) system for Building 3862

2014-01-01T23:59:59.000Z

339

Proposal for the award of a contract for the design, supply, installation and commissioning of Heating, Ventilation and Air-Conditioning (HVAC) systems for the PS accelerator infrastructure  

E-Print Network (OSTI)

Proposal for the award of a contract for the design, supply, installation and commissioning of Heating, Ventilation and Air-Conditioning (HVAC) systems for the PS accelerator infrastructure

2012-01-01T23:59:59.000Z

340

Proposal to negotiate an amendment to an existing contract for the supply and installation of an HVAC system for the HIE-ISOLDE infrastructure  

E-Print Network (OSTI)

Proposal to negotiate an amendment to an existing contract for the supply and installation of an HVAC system for the HIE-ISOLDE infrastructure

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hvac zone summary" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Proposal for the award of a contract for dismantling, removal and packaging of the existing Heating, Ventilation and Air-Conditioning (HVAC) systems in the PS tunnel  

E-Print Network (OSTI)

Proposal for the award of a contract for dismantling, removal and packaging of the existing Heating, Ventilation and Air-Conditioning (HVAC) systems in the PS tunnel

2012-01-01T23:59:59.000Z

342

Energy saving by integrated control of natural ventilation and HVAC systems using model guide for comparison  

Science Journals Connector (OSTI)

Abstract Integrated control by controlling both natural ventilation and HVAC systems based on human thermal comfort requirement can result in significant energy savings. The concept of this paper differs from conventional methods of energy saving in HVAC systems by integrating the control of both these HVAC systems and the available natural ventilation that is based on the temperature difference between the indoor and the outdoor air. This difference affects the rate of change of indoor air enthalpy or indoor air potential energy storage. However, this is not efficient enough as there are other factors affecting the rate of change of indoor air enthalpy that should be considered to achieve maximum energy saving. One way of improvement can be through the use of model guide for comparison (MGFC) that uses physical-empirical hybrid modelling to predict the rate of change of indoor air potential energy storage considering building fabric and its fixture. Three methods (normal, conventional and proposed) are tested on an identical residential building model using predicted mean vote (PMV) sensor as a criterion test for thermal comfort standard. The results indicate that the proposed method achieved significant energy savings compared with the other methods while still achieving thermal comfort.

Raad Z. Homod; Khairul Salleh Mohamed Sahari; Haider A.F. Almurib

2014-01-01T23:59:59.000Z

343

Part II: Project Summaries Project Summaries  

E-Print Network (OSTI)

Part II: Project Summaries Part II Project Summaries #12;22 Math & Computational Sciences Division generally cannot be achieved for reasonable computational cost. Applications that require modeling of this project is to advance the state of the art in electromagnetic computations by eliminating three existing

Perkins, Richard A.

344

BETTER BUILDINGS PARTNER SUMMARIES  

Energy.gov (U.S. Department of Energy (DOE))

In addition to Better Buildings Neighborhood Program Summary of Reported Data From July 1, 2010 – September 30, 2013, each document below presents a summary of data reported by an organization...

345

Summaries of PIE Reports  

Science Journals Connector (OSTI)

In the following section, summary reports of the Process Improvement Experiments are presented that have been assigned to the Problem Domain Software Quality, Testing, Validation and Verification. These summaries...

Michael Haug; Eric W. Olsen; Luisa Consolini

2001-01-01T23:59:59.000Z

346

Las Vegas Roundtable Summary  

Energy.gov (U.S. Department of Energy (DOE))

Summary report from the DOE Office of Indian Energy roundtable held on March 16, 2011, in Las Vegas, Nevada.

347

COMPLIANCE FORMS SUMMARY APPENDIX A  

E-Print Network (OSTI)

of these phases are described below. Building Permit Phase Documentation The Standards Section 10-103(a) requires specifications needed for new construction compliance, including HVAC capacity and the results of the heating and cooling load calculations need to be to be attached. The Standards require that a certificate

348

Air filters from HVAC systems as possible source of volatile organic compounds (VOC) – laboratory and field assays  

Science Journals Connector (OSTI)

The emission of volatile organic compounds (VOC) from air filters of HVAC systems was to be evaluated. In a first study carbonyl compounds (14 aldehydes and two ketones) were measured by reacting them with 2,4-dinitrophenylhydrazine (DNPH). Analysis was done by HPLC and UV detection. In laboratory experiments pieces of used and unused HVAC filters were incubated in test chambers. Filters to be investigated were taken from a filter bank of a large HVAC system in the centre of Berlin. First results show that – among those compounds – formaldehyde and acetone were found in higher concentrations in the test chambers filled with used filters in comparison to those with unused filters. Parallel field measurements were carried out at the prefilter and main filter banks of the two HVAC systems. Here measurements were carried out simultaneously before and after the filters to investigate whether those aldehydes or ketones arise from the filter material on site. Formaldehyde and acetone significantly increased in concentration after the filters of one HVAC system. In parallel experiments microorganisms were proved to be able to survive on air filters. Therefore, a possible source of formaldehyde and acetone might be microbes.

Hans Schleibinger; Henning Rüden

1999-01-01T23:59:59.000Z

349

Validation of a Building Simulation Tool Using Field Data for Three Identical Configuration Full-Serve Restaurants Using Different HVAC Systems  

E-Print Network (OSTI)

A new building application for a pre-existing HVAC software tool which calculates the benefits of desiccant-assisted HVAC equipment versus the performance of a standard vapor-compression system is used to model the monitored results, see Yborra...

Brillhart, P. L.; Worek, W. M.

2000-01-01T23:59:59.000Z

350

Building America Best Practices Series Vol. 14: Energy Renovations - HVAC: A Guide for Contractors to Share with Homeowners  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC HVAC A Guide for Contractors to Share with Homeowners PREPARED BY Pacific Northwest National Laboratory & Oak Ridge National Laboratory August 2011 August 2011 * PNNL-20421 BUILDING AMERICA BEST PRACTICES SERIES VOLUME 14. R BUILDING AMERICA BEST PRACTICES SERIES Energy Renovations Volume 14: HVAC A Guide for Contractors to Share with Homeowners Prepared by Pacific Northwest National Laboratory Program Manager: Michael C. Baechler Theresa L. Gilbride, Michael C. Baechler, Marye G. Hefty, and James R. Hand and Oak Ridge National Laboratory Pat M. Love August 2011 Prepared for the U.S. Department of Energy Building America Program PNNL-20421 Pacific Northwest National Laboratory Richland, Washington 99352 Contract DE-AC05-76RLO 1830 This report was prepared as an account of work sponsored by an agency of the

351

HVAC filtration for controlling infectious airborne disease transmission in indoor environments: Predicting risk reductions and operational costs  

Science Journals Connector (OSTI)

Abstract This work describes and applies a methodology for estimating the impact of recirculating heating, ventilating, and air-conditioning (HVAC) particle filters on the control of size-resolved infectious aerosols in indoor environments using a modified version of the Wells-Riley model for predicting risks of infectious disease transmission. Estimates of risk reductions and associated operational costs of both HVAC filtration and equivalent outdoor air ventilation are modeled and compared using a case study of airborne transmission of influenza in a hypothetical office space. Overall, recirculating HVAC filtration was predicted to achieve risk reductions at lower costs of operation than equivalent levels of outdoor air ventilation, particularly for MERV 13–16 filters. Medium efficiency filtration products (MERV 7–11) are also inexpensive to operate but appear less effective in reducing infectious disease risks.

Parham Azimi; Brent Stephens

2013-01-01T23:59:59.000Z

352

HVAC systems in the current stock of U. S. K-12 schools. Final report, May 91-Mar 92  

SciTech Connect

The report summarizes information on heating, ventilating, and air-conditioning (HVAC) systems commonly found in U.S. school buildings and the effect that operating these systems has on indoor radon levels. The report describes the ability of various HVAC systems to pressurize and ventilate classroom spaces, how they operate, and how they are controlled. Some information is given to compare systems from the standpoint of energy use, cost, and their ability to maintain stable levels of static pressure in classrooms and/or to adequately ventilate the spaces. There do not appear to be any well defined trends in types of HVAC systems involved in current school building construction and modification. Systems looked at include those using reheat and/or mixing, unit ventilators (UVs), and two-fan, dual-duct variable air volume (VAV) systems.

Parker, J.D.

1992-07-01T23:59:59.000Z

353

Federal Acquisition Regulation; Federal Acquisition Circular 2005-47; Summary  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7; Summary 7; Summary This document summarizes the Federal Acquisition Regulation (FAR) rules agreed to by the Civilian Agency Acquisition Council and the Defense Acquisition Regulations Council (Councils) in this Federal Acquisition Circular (FAC) 2005-47. All were effective December 13, 2010 except Items II, HUB Zone, and VI, Pass Through, which will be effective January 12, 2011. List of Rules in FAC 2005-47 Item Subject FAR case Analyst ------------------------------------------------------------------------------------------------------------ ---- I..................................... Notification of Employee 2010-006 McFadden.

354

Warming impact on energy use of HVAC system in buildings of different thermal qualities and in different climates  

Science Journals Connector (OSTI)

Abstract In order to combat climate change, energy use in the building must be further reduced. Heating ventilation and air conditioning (HVAC) systems in residential buildings account for considerable fraction of global energy consumption. The potential contribution the domestic sector can make in reducing energy consumption is recognized worldwide. The driving energy of \\{HVACs\\} depends on the thermal quality of the building envelope (TQBE) and outside temperature. Definitely, building regulations are changing with the time toward reduce the thermal loads of buildings. However, most of the existing residential buildings were built to lower TQBE. For instant, 72% of residential dwellings in the 15-EU were built before 1972. To investigate the impact of warming on driving energy of \\{HVACs\\} of a residential building a computer model was developed. Three climate categories/cities were considered, i.e. Stockholm (cold), Istanbul (mild), and Doha (hot). In each city, two buildings were modeled: one was assumed to be built according to the current local buildings regulations (standard TQBE), while the anther was built to lower TQBE. The simulations were run for present and future (in 2050) outdoor designing conditions. The calculations show that the impact of the warming on annual driving energy of \\{HVACs\\} (reduction or increase) depends very much on the climate category and on the TQBE. Based on the climate and TQBE, the change in annual \\{HVACs\\} energy varies from ?7.4% (in cold climate) to 12.7% (in hot climate). In mild climate, it was shown that the warming does not have significant impact on annual \\{HVACs\\} energy. Improving the TQBE can mitigate the impact of the warming.

Mohamad Kharseh; Lobna Altorkmany; Mohammed Al-Khawaj; Ferri Hassani

2014-01-01T23:59:59.000Z

355

Unsaturated Zone and Saturated Zone Transport Properties (U0100)  

SciTech Connect

This Analysis/Model Report (AMR) summarizes transport properties for the lower unsaturated zone hydrogeologic units and the saturated zone at Yucca Mountain and provides a summary of data from the Busted Butte Unsaturated Zone Transport Test (UZTT). The purpose of this report is to summarize the sorption and transport knowledge relevant to flow and transport in the units below Yucca Mountain and to provide backup documentation for the sorption parameters decided upon for each rock type. Because of the complexity of processes such as sorption, and because of the lack of direct data for many conditions that may be relevant for Yucca Mountain, data from systems outside of Yucca Mountain are also included. The data reported in this AMR will be used in Total System Performance Assessment (TSPA) calculations and as general scientific support for various Process Model Reports (PMRs) requiring knowledge of the transport properties of different materials. This report provides, but is not limited to, sorption coefficients and other relevant thermodynamic and transport properties for the radioisotopes of concern, especially neptunium (Np), plutonium (Pu), Uranium (U), technetium (Tc), iodine (I), and selenium (Se). The unsaturated-zone (UZ) transport properties in the vitric Calico Hills (CHv) are discussed, as are colloidal transport data based on the Busted Butte UZTT, the saturated tuff, and alluvium. These values were determined through expert elicitation, direct measurements, and data analysis. The transport parameters include information on interactions of the fractures and matrix. In addition, core matrix permeability data from the Busted Butte UZTT are summarized by both percent alteration and dispersion.

J. Conca

2000-12-20T23:59:59.000Z

356

Building America Expert Meeting Report: Transitioning Traditional HVAC Contractors to Whole House Performance Contractors  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Transitioning Transitioning Traditional HVAC Contractors to Whole House Performance Contractors Arlan Burdick IBACOS, Inc. October 2011 NOTICE This report was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation,

357

Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System  

NLE Websites -- All DOE Office Websites (Extended Search)

Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage Title Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage Publication Type Conference Proceedings Refereed Designation Refereed LBNL Report Number LBNL-6127E Year of Publication 2013 Authors Mammoli, Andrea, Michael Stadler, Nicholas DeForest, Hans Barsun, Richard Burnett, and Chris Marnay Conference Name 3rd International Conference on Microgeneration and Related Technologies Date Published 04/2013 Conference Location Naples, Italy Keywords absorption cooling, mixed integer programming, optimisation, software-as-a-service, thermal storage Abstract The UNM Mechanical Engineering HVAC system incorporates cooling assisted by a 232 m2 solar thermal array providing heat to a 70 kWthermal absorption chiller. A 30 m3 heat storage tank solar decouples heat production and absorption cooling. Additionally, 350 m3 of chilled water storage shifts the cooling electrical load of this high desert location off-peak. While this system already provides substantial energy and cost savings compared to similar conventional buildings, there are still opportunities for improvement. Absorption cooling (augmented by an electrically powered central cooling loop) suffers from parasitic electric loads from a cooling tower pump, a cooling tower fan, and hot and chilled water circulation pumps. Moreover, depending on seasonal, weather, occupancy, and cost conditions, the cold storage tanks may only need partial charging to meet the next day's net building load, and losses need to be considered. Optimally operating this complex thermal-electrical system poses a challenging mathematical problem. A model of the system was built on LBNL's Distributed Resources Customer Adoption Model (DER-CAM) platform. A direct interface between the building energy control system, and DER-CAM hosted on LBNL's server was developed. This interface delivers daily scheduling based on weather forecasts, tariffs, etc., to the building controller. It is found that energy cost savings can be proportionally substantial (almost 30%) - although in this case the payback period for system implementation is long, due to the very low energy consumption of the building. Also, it is found that accurate weather forecasting is a key ingredient of the optimization, although local biases can be corrected for in the optimization.

358

Methodology to Analyze the Sensitivity of Building Energy Consumption to HVAC System Sensor Error  

E-Print Network (OSTI)

Siemens TR 200/300 1 yr. (Siemens) GE Sensing Telaire 7000 1 yr.(GE-B,2011) 2.5.2 Pressure Sensors Based on the review of the manufacturers? specification literature, the most commonly used pressure sensors in HVAC systems are piezoresistive pressure... divided by the pump efficiency. Wpump=Wfluid/Effpump (42) Wpump(hp)=V(gal/min) ?Ptotal(ft-H2O)/(3960(gal-ft/min-hp)*Effpump) (43) The total pressure drop through the piping system includes the difference in static pressure of the inlet and outlet...

Ma, Liang

2012-02-14T23:59:59.000Z

359

Self-Correcting HVAC Controls: Algorithms for Sensors and Dampers in Air-Handling Units  

SciTech Connect

This report documents the self-correction algorithms developed in the Self-Correcting Heating, Ventilating and Air-Conditioning (HVAC) Controls project funded jointly by the Bonneville Power Administration and the Building Technologies Program of the U.S. Department of Energy. The algorithms address faults for temperature sensors, humidity sensors, and dampers in air-handling units and correction of persistent manual overrides of automated control systems. All faults considered create energy waste when left uncorrected as is frequently the case in actual systems.

Fernandez, Nicholas; Brambley, Michael R.; Katipamula, Srinivas

2009-12-31T23:59:59.000Z

360

COMPARATIVE STUDY AMONG HYBRID GROUND SOURCE HEAT PUMP SYSTEM, COMPLETE GROUND SOURCE HEAT PUMP AND CONVENTIONAL HVAC SYSTEM  

SciTech Connect

In this paper, a hotel with hybrid geothermal heat pump system (HyGSHP) in the Pensacola is selected and simulated by the transient simulation software package TRNSYS [1]. To verify the simulation results, the validations are conducted by using the monthly average entering water temperature, monthly facility consumption data, and etc. And three types of HVAC systems are compared based on the same building model and HVAC system capacity. The results are presented to show the advantages and disadvantages of HyGSHP compared with the other two systems in terms of energy consumptions, life cycle cost analysis.

Jiang Zhu; Yong X. Tao

2011-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "hvac zone summary" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Essential Services Meeting Summary  

SciTech Connect

This summary of proceedings report focuses on an end-of-grant meeting at which grantees for Project Area 5 were convened.

HCTT CHE

2010-03-01T23:59:59.000Z

362

XRM2005 Conference Summary  

E-Print Network (OSTI)

some of the other organizers. (from the Conference web site)XRM 2005 – Conference Summary Janos Kirz Advanced LightThe presentations at the Conference covered the latest

Kirz, Janos

2005-01-01T23:59:59.000Z

363

Final Meeting Summary ...  

NLE Websites -- All DOE Office Websites (Extended Search)

Health, Safety, and Environmental Protection Committee November 8, 2012 FINAL MEETING SUMMARY HANFORD ADVISORY BOARD HEALTH SAFETY AND ENVIRONMENTAL PROTECTION COMMITTEE November...

364

Peak Demand Reduction from Pre-Cooling with Zone Temperature Reset in an Office Building  

SciTech Connect

The objective of this study was to demonstrate the potential for reducing peak-period electrical demand in moderate-weight commercial buildings by modifying the control of the HVAC system. An 80,000 ft{sup 2} office building with a medium-weight building structure and high window-to-wall ratio was used for a case study in which zone temperature set-points were adjusted prior to and during occupancy. HVAC performance data and zone temperatures were recorded using the building control system. Additional operative temperature sensors for selected zones and power meters for the chillers and the AHU fans were installed for the study. An energy performance baseline was constructed from data collected during normal operation. Two strategies for demand shifting using the building thermal mass were then programmed in the control system and implemented progressively over a period of one month. It was found that a simple demand limiting strategy performed well in this building. This strategy involved maintaining zone temperatures at the lower end of the comfort region during the occupied period up until 2 pm. Starting at 2 pm, the zone temperatures were allowed to float to the high end of the comfort region. With this strategy, the chiller power was reduced by 80-100% (1-2.3 W/ft{sup 2}) during normal peak hours from 2-5 pm, without causing any thermal comfort complaints. The effects on the demand from 2-5 pm of the inclusion of pre-cooling prior to occupancy are unclear.

Xu, Peng; Haves, Philip; Piette, Mary Ann; Braun, James

2006-08-01T23:59:59.000Z

365

Peak demand reduction from pre-cooling with zone temperature reset in an office building  

SciTech Connect

The objective of this study was to demonstrate the potential for reducing peak-period electrical demand in moderate-weight commercial buildings by modifying the control of the HVAC system. An 80,000 ft{sup 2} office building with a medium-weight building structure and high window-to-wall ratio was used for a case study in which zone temperature set-points were adjusted prior to and during occupancy. HVAC performance data and zone temperatures were recorded using the building control system. Additional operative temperature sensors for selected zones and power meters for the chillers and the AHU fans were installed for the study. An energy performance baseline was constructed from data collected during normal operation. Two strategies for demand shifting using the building thermal mass were then programmed in the control system and implemented progressively over a period of one month. It was found that a simple demand limiting strategy performed well in this building. This strategy involved maintaining zone temperatures at the lower end of the comfort region during the occupied period up until 2 pm. Starting at 2 pm, the zone temperatures were allowed to float to the high end of the comfort region. With this strategy, the chiller power was reduced by 80-100% (1-2.3 W/ft{sup 2}) during normal peak hours from 2-5 pm, without causing any thermal comfort complaints. The effects on the demand from 2-5 pm of the inclusion of pre-cooling prior to occupancy are unclear.

Xu, Peng; Haves, Philip; Piette, Mary Ann; Braun, James

2004-08-01T23:59:59.000Z

366

Other Fresnel Zone Antennas  

Science Journals Connector (OSTI)

In the preceding chapters, theoretical investigations and experiments on a number of Fresnel zone antennas are presented. This chapter is intended to introduce a wider range of Fresnel zone antennas. Section 7...

Y. Jay Guo; Stephen K. Barton

2002-01-01T23:59:59.000Z

367

Enterprise Zone Program (Illinois)  

Energy.gov (U.S. Department of Energy (DOE))

The Enterprise Zone Program provides eligible businesses that relocate or expand to a designated zone with tax incentives such as: 1) an investment tax credit; 2) a job tax credit for each job...

368

Alternative Energy Zone (Ohio)  

Energy.gov (U.S. Department of Energy (DOE))

Ohio's Alternative Energy Zones are made possible through Ohio's Senate Bill 232, which reduced taxes on alternative energy projects. The Alternative Energy Zones are designated on a county-by...

369

A SUMMARY OF COAL IN THE FORT UNION FORMATION (TERTIARY), BIGHORN BASIN,  

E-Print Network (OSTI)

Chapter SB A SUMMARY OF COAL IN THE FORT UNION FORMATION (TERTIARY), BIGHORN BASIN, WYOMING assessment of selected Tertiary coal beds and zones in the Northern RockyMountains and Great Plains region, U...........................................................................................................................SB-1 Coal Production History

370

Zoning and Permitting Resources  

Energy.gov (U.S. Department of Energy (DOE))

Zoning and permitting is commonly controlled by local governments and may be applicable to both residential and commercial properties.

371

Energy efficient control of HVAC systems with ice cold thermal energy storage  

Science Journals Connector (OSTI)

Abstract In heating, ventilation and air conditioning (HVAC) systems of medium/high cooling capacity, energy demands can be matched with the help of thermal energy storage (TES) systems. If properly designed, TES systems can reduce energy costs and consumption, equipment size and pollutant emissions. In order to design efficient control strategies for TES systems, we present a model-based approach with the aim of increasing the performance of HVAC systems with ice cold thermal energy storage (CTES). A simulation environment based on Matlab/Simulink® is developed, where thermal behaviour of the plant is analysed by a lumped formulation of the conservation equations. In particular, the ice CTES is modelled as a hybrid system, where the water phase transitions (solid–melting–liquid and liquid–freezing–solid) are described by combining continuous and discrete dynamics, thus considering both latent and sensible heat. Standard control strategies are compared with a non-linear model predictive control (NLMPC) approach. In the simulation examples model predictive control proves to be the best control solution for the efficient management of ice CTES systems.

Alessandro Beghi; Luca Cecchinato; Mirco Rampazzo; Francesco Simmini

2014-01-01T23:59:59.000Z

372

HVAC Design Strategy for a Hot-Humid Production Builder, Houston, Texas (Fact Sheet)  

SciTech Connect

BSC worked directly with the David Weekley Homes - Houston division to redesign three floor plans in order to locate the HVAC system in conditioned space. The purpose of this project is to develop a cost effective design for moving the HVAC system into conditioned space. In addition, BSC conducted energy analysis to calculate the most economical strategy for increasing the energy performance of future production houses. This is in preparation for the upcoming code changes in 2015. The builder wishes to develop an upgrade package that will allow for a seamless transition to the new code mandate. The following research questions were addressed by this research project: 1. What is the most cost effective, best performing and most easily replicable method of locating ducts inside conditioned space for a hot-humid production home builder that constructs one and two story single family detached residences? 2. What is a cost effective and practical method of achieving 50% source energy savings vs. the 2006 International Energy Conservation Code for a hot-humid production builder? 3. How accurate are the pre-construction whole house cost estimates compared to confirmed post construction actual cost? BSC and the builder developed a duct design strategy that employs a system of dropped ceilings and attic coffers for moving the ductwork from the vented attic to conditioned space. The furnace has been moved to either a mechanical closet in the conditioned living space or a coffered space in the attic.

Not Available

2014-03-01T23:59:59.000Z

373

Report on HVAC option selections for a relocatable classroom energy and indoor environmental quality field study  

SciTech Connect

It is commonly assumed that efforts to simultaneously develop energy efficient building technologies and to improve indoor environmental quality (IEQ) are unfeasible. The primary reason for this is that IEQ improvements often require additional ventilation that is costly from an energy standpoint. It is currently thought that health and productivity in work and learning environments requires adequate, if not superior, IEQ. Despite common assumptions, opportunities do exist to design building systems that provide improvements in both energy efficiency and IEQ. This report outlines the selection of a heating, ventilation, and air conditioning (HVAC) system to be used in demonstrating such an opportunity in a field study using relocatable school classrooms. Standard classrooms use a common wall mounted heat pump HVAC system. After reviewing alternative systems, a wall-mounting indirect/direct evaporative cooling system with an integral hydronic gas heating is selected. The anticipated advantages of this system include continuous ventilation of 100 percent outside air at or above minimum standards, projected cooling energy reductions of about 70 percent, inexpensive gas heating, improved airborne particle filtration, and reduced peak load electricity use. Potential disadvantages include restricted climate regions and possible increases in indoor relative humidity levels under some conditions.

Apte, Michael G.; Delp, Woody W.; Diamond, Richard C.; Hodgson, Alfred T.; Kumar, Satish; Rainer, Leo I.; Shendell, Derek G.; Sullivan, Doug P.; Fisk, William J.

2001-10-11T23:59:59.000Z

374

CHARACTERIZATION OF AIRFLOWS NEAR THE EXIT OF HVAC REGISTERS USING LASER DOPPLER VELOCIMETRY (LDV).  

SciTech Connect

A facility to characterize the airflow at the exit of HVAC registers was designed and fabricated. The objective of this work is to obtain velocity and turbulence data at the exit of registers, which can then be used as an input boundary condition in a modern Computational Fluid Dynamics (CFD) code to predict the velocity and temperature distribution in an enclosure, and also the register performance parameters such as throw. During the course of this work, two commonly used registers were tested. Both registers were 8 inch x 4 inch sidewall registers. Laser Doppler Velocimetry was used to measure the axial and vertical components of the velocity vector at various locations across the face of the registers. For the two cases of registers studied here, the results suggest that the velocity field at the very exit of each of these registers scales with the flow rate through the registers. This means that, in the mode of operation in which the supply fan (of an HVAC system) has a ''High'' and ''Low'' setting, similar velocity scaling would result for the type of registers tested here.

TUTU,N.K.; KRISHNA,C.R.; ANDREWS,J.W.; BUTCHER,T.A.

2003-03-13T23:59:59.000Z

375

Combined solar and internal load effects on selection of heat reclaim-economizer HVAC systems  

SciTech Connect

The concern for energy conservation has led to the development and use of heat recovery systems which reclaim the building internal heat before it is discarded in the exhaust air. On the other hand, economizer cycles have been widely used for many years in a variety of types of HVAC systems. Economizer cycles are widely accepted as a means to reduce operating time for chilling equipment when cool outside air is available. It has been suggested that heat reclaim systems should not be used in conjunction with an HVAC system which incorporates an economizer cycle because the economizer operation would result in heat being exhausted which might have been recovered. Others suggest that the economizer cycle can be used economically in a heat recovery system if properly controlled to maintain an overall building heat balance. This study looks at potential energy savings of such combined systems with particular emphasis on the effects of the solar load (amount of glass) and the internal load level (lights, people, appliances, etc.). For systems without thermal storage, annual energy savings of up to 60 percent are predicted with the use of heat reclaim systems in conjunction with economizers when the heat reclaim has priority. These results demonstrate the necessity of complete engineering evaluations if proper selection and operation of combined heat recovery and economizer cycles are to be obtained. This paper includes the basic methodology for making such evaluations.

Sauer, H.J. Jr.; Howell, R.H.; Wang, Z. (Missouri Univ., Rolla, MO (USA). Dept. of Mechanical Engineering)

1990-05-01T23:59:59.000Z

376

Neuro-optimal operation of a variable air volume HVAC&R system  

Science Journals Connector (OSTI)

Low operational efficiency especially under partial load conditions and poor control are some reasons for high energy consumption of heating, ventilation, air conditioning and refrigeration (HVAC&R) systems. To improve energy efficiency, HVAC&R systems should be efficiently operated to maintain a desired indoor environment under dynamic ambient and indoor conditions. This study proposes a neural network based optimal supervisory operation strategy to find the optimal set points for chilled water supply temperature, discharge air temperature and VAV system fan static pressure such that the indoor environment is maintained with the least chiller and fan energy consumption. To achieve this objective, a dynamic system model is developed first to simulate the system behavior under different control schemes and operating conditions. A multi-layer feed forward neural network is constructed and trained in unsupervised mode to minimize the cost function which is comprised of overall energy cost and penalty cost when one or more constraints are violated. After training, the network is implemented as a supervisory controller to compute the optimal settings for the system. Simulation results show that compared to the conventional night reset operation scheme, the optimal operation scheme saves around 10% energy under full load condition and 19% energy under partial load conditions.

Min Ning; M. Zaheeruddin

2010-01-01T23:59:59.000Z

377

Final Meeting Summary ...  

NLE Websites -- All DOE Office Websites (Extended Search)

5 Issue Manager Report-Out on Tank Closure and Waste Management Final Environmental Impact Statement (TC&WM FEIS) Groundwater and Vadose Zone Modeling (JOINT...

378

Studies on intrinsic summary evaluation  

Science Journals Connector (OSTI)

Summary evaluation has gained importance in the research community and seems to be a quite challenging task. Most of the work till date focus on summary generation, while this paper focus on intrinsic summary evaluation. Studies made for preparing the ... Keywords: effectiveness, extraction, inter judge agreement, intrinsic summary evaluation, precision, rank correlation, recall, summarisation, text summary, utility mechanisms

Shanmugasundaram Hariharan; Rengaramanujam Srinivasan

2010-04-01T23:59:59.000Z

379

ETME 422 -REFRIGERATION & HVAC SYSTEMS FALL 2011 LEC -10:00 -10:50am M W F RH 312  

E-Print Network (OSTI)

-1209(h) Office Hours: M-F 1-2p.m. Text: Heating, Ventilating, and Air Conditioning - Analysis and Design. -- Refrigeration and heating, ventilating and air-conditioning (HVAC) for comfort and industrial applications of the fundamentals of Heating, Ventilating, Air Conditioning, and Refrigeration as they relate to human comfort

Dyer, Bill

380

Building America Best Practices Series Vol. 14: Energy Renovations- HVAC: A Guide for Contractors to Share with Homeowners  

Energy.gov (U.S. Department of Energy (DOE))

This guide, which is part of a series of Best Practices guides produced by DOE’s Building America program, describes ways homeowners can reduce their energy costs and improve the comfort, health, and safety of their homes by upgrading their heating, ventilation, and air conditioning (HVAC) equipment.

Note: This page contains sample records for the topic "hvac zone summary" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Proper Setup of HVAC System in Conjunction with Sound Building 'Skin' Design for Alleviation of IAQ and Energy Performance Problems  

E-Print Network (OSTI)

climates, not only because of the loss of energy, but also because of damage that can result to insulation, drywall, and structure in addition to promotion of mold and mildew growth. Proper setup of the HVAC system, in conjunction with sound building “skin...

Rosenberg, M.

2006-01-01T23:59:59.000Z

382

SUMMARY REPORT ANNUAL IABP MEETING  

E-Print Network (OSTI)

SUMMARY REPORT THE 7TH ANNUAL IABP MEETING St. Petersburg, Russia, 3 - 6 June 1997 #12;IABP-7 Summary Report 2 Table of Contents Summary Report-ordinator's Report.......................................................... 20 5. Report of the Data Buoy Co

Rigor, Ignatius G.

383

Nuclear Safety Workshop Summary  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Workshop Summary Workshop Summary September 19-20, 2012 1 Nuclear Safety Workshop Summary On September 19-20, 2012, the U.S. Department of Energy (DOE) held a second Nuclear Safety Workshop covering the results of the Department's actions to improve its posture for analyzing and responding to severe accidents in light of lessons learned from the March 2011 nuclear accident in Japan. Sponsored by DOE and championed by Deputy Secretary of Energy Daniel Poneman, the two-day workshop discussed the lessons learned in a national and international context. The workshop's theme

384

Saltcreek Project Summary  

NLE Websites -- All DOE Office Websites (Extended Search)

Project Summary Project Summary HELP Index Summary Scenario References Student Pages Subject/Content Area: Environmental Science Target Audience: Middle school level - all students, including gifted, learning-disabled, behavior-disordered and limited English proficient Project Goals: As a result of their participation in the Salt Creek Investigation, the students will develop the abilities necessary to do scientific inquiry. They will increase their understanding of factors affecting environmental quality, including the interdependence of organisms, and human-induced hazards. Students will learn how science and technology can help people solve local, national and global environmental problems. Learner Outcomes: Students will: be able to carry out six types of stream monitoring tests.

385

Compilation of ETR Summaries  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Summaries Summaries Office of Technology Innovation and Development Office of Environmental Management November 2011 External Technical Review Summaries Number Title Report Date ETR-1 Flowsheet for the Hanford Waste Treatment Plant (WTP) March 2006 ETR-2 Tank 48 at the Savannah River Site (SRS) August 2006 ETR-3 Demonstration Bulk Vitrification System (DBVS) for Low Activity Waste (LAW) at Hanford September 2006 ETR-4 Salt Waste Processing Facility Design at the Savannah River Site (SRS) November 2006 ETR-5 Remedial System Performance Improvement for the 200-ZP-1/PW-1 Operable Units at Hanford February 2007 ETR-6 Operational Issues at the Environmental Restoration

386

Investigation of IAQ-Relevant Surface Chemistry and Emissions on HVAC Filter Materials  

SciTech Connect

Chemical reactions involving ozone of outdoor origin and indoor materials are known to be significant sources of formaldehyde and other irritant gas-phase oxidation products in the indoor environment. HVAC filters are exposed to particularly high ozone concentrations--close to outdoor levels. In this study, we investigated chemical processes taking place on the surface of filters that included fiberglass, polyester, cotton/polyester blend and synthetic (e.g., polyolefin) filter media. Ozone reactions were studied on unused filter media, and on filters that were deployed for 3 months in two different locations: at the Lawrence Berkeley National Laboratory and at the Port of Oakland. Specimens from each filter were exposed to ozone under controlled conditions in a laboratory flow tube at a constant flow of dry or humidified air (50percent relative humidity). Ozone was generated with a UV source upstream of the flow tube, and monitored using a photometric detector. Ozone breakthrough curves were recorded for each sample exposed to ~;;150 ppbv O3 for periods of ~;;1000 min, from which we estimated their uptake rate. Most experiments were performed at 1.3 L/min (corresponding to a face velocity of 0.013 m/s), except for a few tests performed at a higher airflow rate, to obtain a face velocity of 0.093 m/s, slightly closer to HVAC operation conditions. Formaldehyde and acetaldehyde, two oxidation byproducts, were collected downstream of the filter and quantified. Emissions of these volatile aldehydes were consistently higher under humidified air than under dry conditions, at which levels were near the limit of detection. Our results confirm that there are significant reactions of ozone as air containing ozone flows through HVAC filters, particularly when the filters are loaded with particles and the air is humidified. The amount of ozone reacted was not clearly related to the types of filter media, e.g., fiberglass versus synthetic. Specific fiberglass filters that were coated with an impaction oil showed significantly higher formaldehyde emissions than most other samples. Those emissions were magnified in the presence of particles (i.e., in used filters), and were observed even in the absence of ozone, which suggests that hydrolysis of filter binder or tackifier additives may be the reason for those high emissions. Mass balance calculations indicate that the emission rates of formaldehyde and acetaldehyde from the filters are generally not large enough to substantially increase indoor formaldehyde or acetaldehyde concentrations.

Destaillats, Hugo; Fisk, William J.

2010-02-01T23:59:59.000Z

387

Final Meeting Summary Page 1  

NLE Websites -- All DOE Office Websites (Extended Search)

June 5, 2013 FINAL MEETING SUMMARY HANFORD ADVISORY BOARD PUBLIC INVOLVEMENT & COMMUNICATION COMMITTEE June 5, 2013 Richland, WA Topics in this Meeting Summary Opening...

388

Final Meeting Summary Page 1  

NLE Websites -- All DOE Office Websites (Extended Search)

October 11, 2012 FINAL MEETING SUMMARY HANFORD ADVISORY BOARD HEALTH, SAFETY AND ENVIRONMENTAL PROTECTION COMMITTEE October 11, 2012 Richland, WA Topics in this Meeting Summary...

389

Final Meeting Summary Page 1  

NLE Websites -- All DOE Office Websites (Extended Search)

August 9, 2012 FINAL MEETING SUMMARY HANFORD ADVISORY BOARD HEALTH, SAFETY AND ENVIRONMENTAL PROTECTION COMMITTEE August 9, 2012 Richland, WA Topics in this Meeting Summary Opening...

390

Final Meeting Summary Page 1  

NLE Websites -- All DOE Office Websites (Extended Search)

7, 2014 FINAL MEETING SUMMARY HANFORD ADVISORY BOARD RIVER AND PLATEAU COMMITTEE October 7, 2014 Richland, WA Topics in this Meeting Summary Opening ......

391

Final Meeting Summary Page 1  

NLE Websites -- All DOE Office Websites (Extended Search)

March 5, 2014 FINAL MEETING SUMMARY HANFORD ADVISORY BOARD PUBLIC INVOLVEMENT COMMITEE March 5, 2014 Kennewick, WA Topics in this Meeting Summary Welcome and Introduction...

392

Final Meeting Summary Page 1  

NLE Websites -- All DOE Office Websites (Extended Search)

September 3, 2014 FINAL MEETING SUMMARY HANFORD ADVISORY BOARD PUBLIC INVOLVEMENT COMMITTEE September 3, 2014 Pasco, WA Topics in this Meeting Summary Welcome ......

393

Final Meeting Summary Page 1  

NLE Websites -- All DOE Office Websites (Extended Search)

October 8, 2014 FINAL MEETING SUMMARY HANFORD ADVISORY BOARD TANK WASTE COMMITTEE October 8, 2014 Richland, WA Topics in this Meeting Summary Opening ......

394

Executive Summary | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Summary Executive Summary How clean energy investments can be used to spur local economic development. Spurring Local Economic Development with Clean Energy Investments:...

395

Final Meeting Summary Page 1  

NLE Websites -- All DOE Office Websites (Extended Search)

March 6, 2013 FINAL MEETING SUMMARY HANFORD ADVISORY BOARD RIVER AND PLATEAU COMMITTEE March 6, 2013 Richland, WA Topics in this Meeting Summary Opening ......

396

Final Meeting Summary Page 1  

NLE Websites -- All DOE Office Websites (Extended Search)

meeting (May), but to meet Ecology's submittal timeline, the committee agreed to review the summary and adopt it via email. Ecology will include the final meeting summary...

397

NISE 2012 Award Summaries  

NLE Websites -- All DOE Office Websites (Extended Search)

Table 2012 NISE Awards Summary Table Investigator NERSC repo Hours awarded DOE Office Project Title Gilbert Compo, University of Colorado at Boulder m958 10,000,000 BER Climate...

398

SSRL29 Workshop Summaries  

NLE Websites -- All DOE Office Websites (Extended Search)

Workshop Summaries X-ray Imaging and Spectro-microscopy: the Present and the Future< font> (Chairs: John Miao and Keith Hodgson) This workshop provided a forum to discuss the...

399

HVAC Program  

NLE Websites -- All DOE Office Websites (Extended Search)

to support our goal of achieving regional efficiency targets. Commercial Ductless Heat Pumps A new BPA Qualified measure has been available since April 2011. The measure...

400

Dust loading on electrostatitically charged filters in a standard test and a real HVAC system  

Science Journals Connector (OSTI)

The efficiency and pressure drop of filters made from synthetic fibres carrying electrostatic charges and filters made from uncharged glass fibres were measured repeatedly for more than 19 weeks in operating HVAC systems. Results showed efficiency reductions as large as 40% for the filters made from charged fibres whereas the efficiency of filters made from uncharged fibres changed little. Clean filters were sent to a testing laboratory for efficiency measurements according to ASHRAE Standard 52.2-1999. When the filters experienced accelerated dust loading according to the ASHRAE procedure, the efficiency of both the glass and synthetic fibre filters increased. Efficiency reductions like those observed for the charged filters during actual use were not replicated by this standard test.

Peter C. Raynor; Soo Jae Chae

2003-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hvac zone summary" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Impact of HVAC filter on indoor air quality in terms of ozone removal and carbonyls generation  

Science Journals Connector (OSTI)

Abstract This study aims at detecting ozone removal rates and corresponding carbonyls generated by ozone reaction with HVAC filters from various building, i.e., shopping mall, school, and office building. Studies were conducted in a small-scale environmental chamber. By examining dust properties including organic carbon proportion and specific surface area of dusts adsorbed on filters along with ozone removal rates and carbonyls generation rate, the relationship among dust properties, ozone removal rates, and carbonyls generation was identified. The results indicate a well-defined positive correlation between ozone removal efficiency and carbonyls generation on filters, as well as a positive correlation among the mass of organic carbon on filters, ozone removal efficiency and carbonyls generations.

Chi-Chi Lin; Hsuan-Yu Chen

2014-01-01T23:59:59.000Z

402

Archived Reference Climate Zone: 2B Phoenix, Arizona  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

403

Archived Reference Climate Zone: 2B Phoenix, Arizona  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

404

Archived Reference Climate Zone: 4C Seattle, Washington  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

405

Archived Reference Climate Zone: 3C San Francisco, California  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

406

Archived Reference Climate Zone: 3B Los Angeles, California  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

407

Archived Reference Climate Zone: 6A Minneapolis, Minnesota  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

408

Archived Reference Climate Zone: 3A Atlanta, Georgia  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

409

Archived Reference Climate Zone: 4A Baltimore, Maryland  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

410

Archived Reference Climate Zone: 6A Minneapolis, Minnesota  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

411

Archived Reference Climate Zone: 1A Miami, Florida  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

412

Archived Reference Climate Zone: 6B Helena, Montana  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

413

Archived Reference Climate Zone: 5B Boulder, Colorado  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

414

Archived Reference Climate Zone: 3B Las Vegas, Nevada  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

415

Archived Reference Climate Zone: TMY2 Weather Data  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

416

Archived Reference Climate Zone: 5A Chicago, Illinois  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

417

Archived Reference Climate Zone: 5A Chicago, Illinois  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

418

Archived Reference Climate Zone: 2A Houston, Texas  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

419

Archived Reference Climate Zone: 4B Albuquerque, New Mexico  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

420

Archived Reference Climate Zone: 5B Boulder, Colorado  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

Note: This page contains sample records for the topic "hvac zone summary" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Archived Reference Climate Zone: 3B Los Angeles, California  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

422

Archived Reference Climate Zone: 3C San Francisco, California  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

423

Archived Reference Climate Zone: 3A Atlanta, Georgia  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

424

Archived Reference Climate Zone: 3B Las Vegas, Nevada  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

425

Archived Reference Climate Zone: 6B Helena, Montana  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

426

Archived Reference Climate Zone: 2A Houston, Texas  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

427

Archived Reference Climate Zone: 4C Seattle, Washington  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

428

Archived Reference Climate Zone: 4A Baltimore, Maryland  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

429

Archived Reference Climate Zone: 1A Miami, Florida  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

430

Archived Reference Climate Zone: TMY2 Weather Data  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

431

Can ASHRAE Standard 62-1989 Requirements be Satisfied while Maintaining Moisture Control using Stock HVAC Equipment in Hot, Humid Climates?  

E-Print Network (OSTI)

increase latent loads more than sensible loads, requiring lower sensible heat ratios. Stock HVAC package units and split systems are not available with the requisite sensible heat ratios, and cannot maintain moisture control in small commercial buildings...

Turner, S. C.

1996-01-01T23:59:59.000Z

432

Continuous Energy Management of the HVAC&R System in an Office Building System Operation and Energy Consumption for the Eight Years after Building Completion  

E-Print Network (OSTI)

The authors continuously studied the energy consumption of a heating, ventilating, air- conditioning and refrigerating (HVAC&R) system in an office for the operation of the system in terms of its expected performance. A fault in the system control...

Akashi, Y.; Shinozaki, M.; Kusuda, R.; Ito, S.

2006-01-01T23:59:59.000Z

433

Renaissance Zones (North Dakota)  

Energy.gov (U.S. Department of Energy (DOE))

Renaissance Zones allow qualifying businesses and individuals to claim one or more tax incentives for purchasing, leasing, or making improvements to real property located in a North Dakota...

434

Market assessment for active solar heating and cooling products. Category B: a survey of decision-makers in the HVAC marketplace. Final report  

SciTech Connect

A comprehensive evaluation of the market for solar heating and cooling products for new and retrofit markets is reported. The emphasis is on the analysis of solar knowledge among HVAC decision makers and a comprehensive evaluation of their solar attitudes and behavior. The data from each of the following sectors are described and analyzed: residential consumers, organizational and manufacturing buildings, HVAC engineers and architects, builders/developers, and commercial/institutional segments. (MHR)

None

1980-09-01T23:59:59.000Z

435

STEP Participant Survey Executive Summary  

Energy.gov (U.S. Department of Energy (DOE))

STEP Participant Survey Executive Summary, from the Tool Kit Framework: Small Town University Energy Program (STEP).

436

Philadelphia Summary of Reported Data  

Energy.gov (U.S. Department of Energy (DOE))

Summary of data reported by Better Buildings Neighborhood Program partner Philadelphia, Pennsylvania.

437

Fire Protection Program: Summary  

NLE Websites -- All DOE Office Websites (Extended Search)

Summary Summary Since May 1950, an Annual Fire Protection Program Summary has been submitted by DOE's fire protection community. Currently, this report is required by section 5a.(8) of DOE Order 231.1. "Environment, Safety and Health Reporting." In 1999, an automation initiative was undertaken to streamline data collection and provide a more through review of DOE Reporting Element activities. This action resulted in the delayed publications of the CY 1999 and 2000 reports until 2002. It is now possible however to view all Annual Summary Reporting Element responses since 1991 at the Site, Operations, Lead Program Secretarial Office and Headquarters levels. Additionally, a build-in reference to other DOE reporting activities (CAIRS and ORPS) is available that allows Reporting Elements and managers the opportunity to review all fire protection events along previously mentioned categories. Reports listed below were generated from this application. To obtain a copy of the Annual Summary Application please contact Jim Bisker in the Office of Nuclear and Facility Safety Policy (EH-53) at (301)903-6542 or Jim Bisker.

438

Climate Zones Robinson Projection  

E-Print Network (OSTI)

Climate Zones Africa ´Robinson Projection Copyright 2007. The Trustees of Columbia University University. Population, Landscape, and Climate Estimates (PLACE). Further information available at: http://sedac.ciesin.columbia.edu/place/ Publish Date: 03/13/07 0 500 km Climate zones were taken from the Köppen Climate Classification map

Columbia University

439

FY 2014 Metric Summary | Department of Energy  

Office of Environmental Management (EM)

4 Metric Summary FY 2014 Metric Summary FY 2014 Q1 Metric Summary.pdf FY 2014 Q2 Metric Summary.pdf FY 2014 Q3 Metric Summary.pdf More Documents & Publications FY 2014 Q3 Metric...

440

Summary-Final.PDF  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

SUMMARY SUMMARY June 2000 1 SUMMARY This document constitutes the first edition of a long-term research and development (R&D) plan for nuclear technology in the United States. Introduction In 1998, DOE established the Nuclear Energy Research Advisory Committee (NERAC) to provide advice to the Secretary and to the Director, Office of Nuclear Energy, Science, and Technology (NE), on the broad range of non-defense DOE nuclear technology programs. The NERAC recommended development of a long-range R&D program. This R&D plan is a result of that recommendation and is the first of what is expected to be an iterated series of long-range plans for nuclear energy in the Department of Energy. To develop this plan, 145 nuclear and non-nuclear scientists, engineers, and academics

Note: This page contains sample records for the topic "hvac zone summary" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Use of EMCS Recorded Data to Identify Potential Savings Due to Improved HVAC Operations & Maintenance (O&M)  

E-Print Network (OSTI)

Use of EMCS Recorded Data to Identify Potential Savings Due to Improved HVAC Operations & Maintenance(O&M) Mingsheng Liu, Yeqiao Zhu, and David Claridge Energy Systems Laboratory Texas A&M University ABSTRACT In most chiller and boiler central... and cooling energy consumption using an appropriate model [Liu 1995, Liu and Claridge 19951 with the bin weather data for each building. Step 5: Calculate the campus consumption as the sum of consumption of all buildings. Step 6: Compare the simulated...

Liu, M.; Zhu, Y.; Claridge, D. E.

1996-01-01T23:59:59.000Z

442

Capability of air filters to retain airborne bacteria and molds in heating, ventilating and air-conditioning (HVAC) systems  

Science Journals Connector (OSTI)

The capability of air filters (filterclass: F6, F7) to retain airborne outdoor microorganisms was examined in field experiments in two heating, ventilating and air conditioning (HVAC) systems. At the beginning of the 15-month investigation period, the first filter stages of both HVAC systems were equipped with new unused air filters. The number of airborne bacteria and molds before and behind the filters were determined simultaneously in 14 days-intervals using 6-stage Andersen cascade impactors. Under relatively dry ( 12 °C) outdoor air conditions air filters led to a marked reduction of airborne microorganism concentrations (bacteria by approximately 70 % and molds by > 80 %). However, during long periods of high relative humidity (> 80 % R. H.) a proliferation of bacteria on air filters with subsequent release into the filtered air occured. These microorganisms were mainly smaller than 1.1 ?m therefore being part of the respirable fraction. The results showed furthermore that one possibility to avoid microbial proliferation is to limit the relative humidity in the area of the air filters to 80 % R. H. (mean of 3 days), e. g. by using preheaters in front of air filters in HVAC-systems.

Martin Möritz; Hans Peters; Bettina Nipko; Hennin Rüden

2001-01-01T23:59:59.000Z

443

Performance analysis of supply and return fans for HVAC systems under different operating strategies of economizer dampers  

Science Journals Connector (OSTI)

HVAC systems and associated equipment consume a relatively large fraction of total building energy consumption, a significant portion of which is attributed to fan operation. The operation of economizer dampers when installed can cause high energy consumption in fans if they are not functioning in proper and optimal manner. This will mainly be due to the potential high pressure drops through those dampers and associated high total pressures that should be developed by supply and/or return fans. It is then necessary to ensure that a proper strategy to operate optimally the economizer dampers is implemented with minimum fan energy use. The paper examines several operation strategies of the economizer dampers and investigates their effects on the performance of both the supply and return fans in HVAC system. It also discusses a new operating strategy for economizer dampers that can lead to lower fan energy use. The strategies are evaluated by simulations for a typically existing HVAC system. Several factors such as the building locations, system characteristics, resistance in the duct where the dampers are installed, supply air temperature and economizer control, and minimum ventilation requirements are also considered during the evaluations. The results show that the way of the economizer dampers been controlled has a significant effect on fan performance and its energy use. The proposed strategy if properly implemented can provide fan energy saving in the range of 5–30%, depending mainly on the number of hours when the system operates in the free cooling mode, damper characteristics, and minimum outdoor air.

Nabil Nassif

2010-01-01T23:59:59.000Z

444

RICAP-07: Summary comments  

E-Print Network (OSTI)

The Roma International Conference on Astroparticle Physics covered gamma-ray astronomy, air shower experiments and neutrino astronomy on three successive days. I organize my brief summary comments into four topics that cut across these three techniques. They are detector calibration, galactic sources, extra-galactic sources and cosmology.

Thomas K. Gaisser

2008-01-29T23:59:59.000Z

445

Sustainability Initiative Executive Summary  

E-Print Network (OSTI)

UW­Madison Sustainability Initiative Executive Summary October 2010 #12;2 We are pleased to present the final report of the campus Sustainability Task Force. This report fulfills the charge we gave to sustainability for consideration by UW­Madison's leadership and campus community. There are many reasons why

Sheridan, Jennifer

446

Summary.qxd  

NLE Websites -- All DOE Office Websites (Extended Search)

S-2 Summary B i r c h C r e ek East Butte Middle Butte Big Southern Butte LAVA Black Canyon Wilderness Study Area Hell's Half Acre Wilderness Study Area C H A L L I S N A T I...

447

Deep Vadose Zone Field Activities  

NLE Websites -- All DOE Office Websites (Extended Search)

HANFORD ADVISORY BOARD, RAP March 6, 2013 Presented by: John Morse DEEP VADOSE ZONE ACTIVITIES Page 2 Deep Vadose Zone Areas Page 3 Deep Vadose Zone Field Activities FY 2014...

448

Development Opportunity Zone Credit  

Energy.gov (U.S. Department of Energy (DOE))

The Development Opportunity Zone Credits incent new and expanding businesses in the Cities of Beloit, Janesville and Kenosha by providing non-refundable tax credits to assist with the creation and...

449

Deep Vadose Zone  

Energy.gov (U.S. Department of Energy (DOE))

The Mission of the Deep Vadose Zone Applied Field Research Initiative is to protect water resources across the DOE complex over the long-term by developing effective solutions to solve DOE’s most...

450

Queen Anne's County- Solar Zoning  

Energy.gov (U.S. Department of Energy (DOE))

Queen Anne's County zoning code allows for ground mounted solar arrays in areas zoned as "open space," "agricultural," and "countryside" districts.

451

Decision Summaries | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Decision Summaries Decision Summaries Decision Summaries RSS January 16, 2014 Summary of Decisions - December 30, 2013 - January 3, 2014 Decisions were issued on: - Privacy Act Appeal January 10, 2014 Summary of Decisions - MM DD YYYY - MM DD YYYY Decisions were issued on: - Personnel Security (10 CFR Part 710) December 27, 2013 Summary of Decisions - December 23, 2013 - December 27, 2013 Decisions were issued on: - Freedom of Information Act Appeal - Personnel Security (10 CFR Part 710) December 20, 2013 Summary of Decisions - December 16, 2013 - December 20, 2013 Decisions were issued on: - Freedom of Information Act Appeal - Personnel Security (10 CFR Part 710) December 13, 2013 Summary of Decisions - December 9, 2013 - December 13, 2013 Decisions were issued on: - Freedom of Information Act Appeal

452

Microsoft Word - Summary.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Summary Summary v TABLE OF CONTENTS Table of Contents .......................................................................................................................................................... v List of Figures .............................................................................................................................................................. vi List of Tables ................................................................................................................................................................ vi Acronyms, Abbreviations, and Conversion Charts ..................................................................................................... vii S.1 Introduction and Purpose and Need ...........................................................................................................S-1

453

Final Meeting Summary Page 1  

NLE Websites -- All DOE Office Websites (Extended Search)

that all summaries are posted to the HAB website once finalized and HAB members can review draft summaries on the SharePoint site. Announcements Liz said a public meeting was...

454

Business Model Guide Executive Summary  

Energy.gov (U.S. Department of Energy (DOE))

The Business Model Guide Executive Summary by the U.S. Department of Energy's Better Buildings Neighborhood Program.

455

Promoting high efficiency residential HVAC equipment: Lessons learned from leading utility programs  

SciTech Connect

The Consortium for Energy Efficiency recently sponsored a study of leading electric utility efforts to promote high efficiency residential HVAC equipment. Given growing concerns from some utilities about the level of expenditures associated with rebate programs, special emphasis was placed on assessing the success of financing and other non-rebate options for promoting efficiency. Emphasis was also placed on review of efforts--rebate or otherwise--to push the market to very high levels of efficiency (i.e., SEER 13). This paper presents the results of the study. It includes discussion of key lessons from the utility programs analyzed. It also examines program participation rates and other potential indicators of market impacts. One notable conclusion is that several utility programs have pushed market shares for SEER 12 equipment to about 50% (the national average is less than 20%). At least one utility program has achieved a 50% market share for SEER 13 equipment (the national average is less than 3%). In general, financing does not appear to have as broad an appeal as consumer rebates. However, one unique utility program which combines the other of customer financing with modest incentives to contractors--in the form of frequent seller points that can be redeemed for advertising, technician training, travel and other merchandise--offers some promise that high participation rates can be achieved without customer rebates.

Neme, C.; Peters, J.; Rouleau, D.

1998-07-01T23:59:59.000Z

456

Predicting the energy use and operation cost of HVAC air filters  

Science Journals Connector (OSTI)

A model has been developed to predict the energy efficiency and annual operation cost for filters installed in an HVAC air handling system using filter data from standard ASHRAE 52.2-2007 filter tests. Thirty filters from six manufacturers were investigated to determine the most energy efficient and cost effective filtration solutions for an airport installation in Vancouver, Canada. A comparison of the output of the proposed model with the ‘kep’ and Wattage methods was performed to highlight the possible differences in filter choice that would be made using alternative approaches. The outcomes have been shown to differ due to data not incorporated in the older models such as filtration efficiency and particulate concentration. The sensitivity of filter cost to model parameters was also studied. It was found that the concentration of particles in the air stream and the cost of electricity had the largest effect on annual cost of operation. Increasing the concentration of particles in the air stream increases the cost of operating the filter and causes the installation of a prefilter upstream of the primary filter to be more economically attractive. Increasing electricity cost also increases the operation cost but has the reverse effect on attractiveness of prefilter installations.

James F. Montgomery; Sheldon I. Green; Steven N. Rogak; Karen Bartlett

2012-01-01T23:59:59.000Z

457

Airflow regulation in variable-speed systems for residential HVAC applications  

SciTech Connect

In the majority of heating, ventilating, and air-conditioning (HVAC) systems, air is the final medium for adding or extracting heat from or to the space to be air conditioned. Air is heated by passing it over a heat transfer device called a coil, which is a heat exchanger with air on the outside and the primary heating/cooling medium (water, steam, electricity, refrigerant, etc.) on the inside. One of the major factors determining heat transfer is the airflow rate, which can be controlled by mechanical means or by controlling the speed of the fan. Centrifugal fans driven by single-speed induction motors traditionally have been used in the JVAC industry but have an airflow characteristic that depends on the static pressure seen by the system. Variable-speed systems are starting to emerge as a strong alternative to traditional systems because of their ability to match the demand of the air-conditioned space, resulting in higher efficiencies and higher comfort. System efficiency can be improved by constraining the range of airflows provided by the fan or blower system in response to system pressure, that is, by controlling the airflow over the heat exchanger. This paper presents a method to regulate airflow independent of the static pressure and without the need for airflow sensors.

Becerra, R.C.; Beifus, B.L. [General Electric Co., Fort Wayne, IN (United States)

1996-11-01T23:59:59.000Z

458

A comparative study on energy consumption for HVAC systems of high-tech \\{FABs\\}  

Science Journals Connector (OSTI)

The unique system dynamics of five different HVAC designs including the RCU (recirculation air unit) system, the MAU (make-up air unit) + RCU system, the MAU + RCU + FCU (fan coil unit) system, the MAU + axial fan system, and the MAU + FFU (fan-filter unit) system for a typical 200 mm DRAM wafer fabrication plant are discussed and compared. The energy performances of the RCU system, the MAU + RCU system, the MAU + RCU + FCU system, and the MAU + axial fan system are 3.8, 1.19, 1.12 and 1.08, respectively, folds that of the most efficient MAU + FFU system. The MAU + axial fan system exhibits slight less efficient in energy performance, compared with the MAU + FFU system. The most influential factor on energy performance between these two systems is the design of the noise abatement system, especially the pressure drop of the silencer, which dominates almost half of the internal static pressure of axial fan. When the static pressure of silencer of the MAU + axial fan system is reduced to 50 Pa, energy consumption of these two systems is comparable. Bypassing a certain portion of FAB return air to mix with make-up air can maximally reduce 50% of energy consumption of the RCU system.

Shih-Cheng Hu; Jhy-Ming Tsao

2007-01-01T23:59:59.000Z

459

Partnership Overview and Summary  

NLE Websites -- All DOE Office Websites (Extended Search)

Phase III Field Test Phase III Field Test Overview and Summary RCSP Initiative Annual Review Meeting Pittsburgh, PA October 6 - 8, 2008 Presented by Brian J. McPherson Southwest Regional Partnership on Carbon Sequestration New Mexico Tech 2 Southwest Regional Partnership on Carbon Sequestration Acknowledgements * Many thanks to the U.S. Department of Energy and NETL for supporting this project * We express our gratitude also to our many industry partners, who have committed a great deal of time, funding and other general support for these projects * The work presented today is co-authored by all partners in the Southwest Partnership 3 Southwest Regional Partnership on Carbon Sequestration * Phase II - Phase III Integration * Summary of Phase III Project * location * site characterization

460

COR Summary of Experience  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

COR SUMMARY OF EXPERIENCE COR SUMMARY OF EXPERIENCE Effective January 1, 2012 CORs who are applying for certification must demonstrate past contracting, acquisition, procurement, program/project management, and general business experience. This experience is based on a set of competencies. Some of the competencies are listed below to use as a reference when you are documenting your previous experience. Use this template to document your experience. Experience should be supported by a written confirmation from the cognizant Contracting Officer/Contract Specialist showing the contract number, title and date(s) to which the experience applied. Once you have completed this document, please forward it and its supporting statement(s) to your Site Acquisition Career Manager (SACM) as part of your application for COR certification.

Note: This page contains sample records for the topic "hvac zone summary" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Wildlife Trade: Summary  

NLE Websites -- All DOE Office Websites (Extended Search)

Project Summary Project Summary Scenario Student Pages Internet Links Index Subject/Content Area: Physical Science, Social Studies, Mathematics, and Learning Strategies Target Audience: Thornridge is a comprehensive high school serving approximately 2,000 ninth through twelfth grade students living southeast of the Chicago city limits. Student backgrounds vary greatly socio-economically (below the poverty line to approximately six figures), ethnically (7% Caucasian, 87% African-American, 6% Hispanic) and culturally. Mobility and unemployment are high. Steel mills, the auto industry, steel processing plants and the construction trades have been the major employers; however, many no longer exist. Student test scores in all areas are below the state mean. Eighty freshmen, identified as performing

462

DESIGN GUIDELINE SUMMARY  

NLE Websites -- All DOE Office Websites (Extended Search)

3 Rev. 3 3 Rev. 3 August 2003 Rev. June 2004 Design Guideline Summary Based on the GEOVISION Report of Stanford Linear Accelerator Tunnel Vibration Measurements Parsons Pasadena, CA For Stanford Linear Accelerator Center Stanford University Stanford, CA Abstract: This summary report is provided in order to suggest how the measurement data from the GEOVision report might be used by SLAC for their proposed Next Linear Collider facility. See the referenced report "Stanford Linear Accelerator Tunnel Vibration Measurements, Conducted at MTA Universal Subway Station, North Hollywood, California", by GEOVision dated July 28, 2003. The following discussions are an attempt to determine an upper bound methodology that can be used for design purposes. The data in the

463

Preliminary Summary of Findings  

NLE Websites -- All DOE Office Websites (Extended Search)

Diversity Focus Groups Diversity Focus Groups Summary Report Prepared by Doug Sarno, The Perspectives Group This report provides a summary of 23 focus groups conducted between November 2008 and January 2009 with Fermilab employees and users. Purpose of the Focus Groups The purpose of the focus groups was to further explore the issues raised by the report of the Committee on the Status of Women in Physics (CSWP) and the Committee on Minorities (COM) of the American Physical Society (APS) on their visit to Fermilab on May 20-21, 2008. That visit included conversations with 47 self-selected participants and raised a number of important issues regarding diversity and workplace issues at Fermilab. The report can be found at http://www.fnal.gov/pub/diversity/files/APS_Report.pdf

464

5.0 SUMMARY  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

0 SUMMARY 0 SUMMARY This environmental assessment provides an analysis of several approaches to the handling of hazardous and mixed wastes at DOE's Mound Plant in Miamisburg, Ohio. The first approach considered, the proposed action, involves the operation of an existing glass metter (also known as a Penberthy Pyro·Converter joule·heated glass furnace) for the treatment of hazardous and mixed wastes. The analysis also considers the no-action alternative, involving the continuance of existing practices at Mound for the handling of hazardous and mixed wastes, as well as various on-site and off-site treatment, storage, or disposal alternatives, Under the proposed action, the primary potential sources of environmental impact are air emissions and effluent discharges, Potential changes in air and water quality may

465

MPhil initiatives summary  

E-Print Network (OSTI)

) Sustainable development for large infrastructure projects (50% input from CU, 50% from MIT) Planning for sustainable development (MIT course tailored for CU) Sustainable energy (MIT course tailored for CU) Design for developing countries (MIT course tailored... CMI Summary of MPhil Initiatives M.Phil in BioScience Enterprise (launched October 2002). Aimed at bio-entrepreneurs, this programme offers teaching on the latest advances in biomedical science, business management, and ethical, legal...

2009-07-13T23:59:59.000Z

466

GLOVEBOX GLOVE CHARACTERIZATION SUMMARY  

SciTech Connect

A task was undertaken to determine primarily the permeation behavior of various glove compounds from four manufacturers. As part of the basic characterization task, the opportunity to obtain additional mechanical and thermal properties presented itself. Consequently, a total of fifteen gloves were characterized for permeation, Thermogravimetric Analysis, Puncture Resistance, Tensile Properties and Dynamic Mechanical Analysis. Detailed reports were written for each characterization technique used. This report contains the summary of the results.

Korinko, P.

2012-05-14T23:59:59.000Z

467

Team Summary | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Team Summary Team Summary Team Summary Team Summary Purpose: Identify, prioritize, and resolve issues for effective site revitalization. Address crosscutting issues. Incorporate ARI's mission into programmatic business practices. Team Attributes and Functions: Coordinate using existing site and program protocols (ARI Task Force is not responsible for site-specific ARI projects or programs). Resolve issues through: Lessons learned Information resources Policy statements Process improvement techniques Proposed legislative changes Partnering with other agencies Facilitation Define, prioritize, and establish deliverable timelines and manage resources. Incorporate co-leadership and cross-functional membership. Team Summaries: Steering Committee Objective: Set the strategic direction, provide overarching leadership,

468

TEC Working Group Topic Groups Security Meeting Summaries | Department...  

Office of Environmental Management (EM)

Summaries TEC Working Group Topic Groups Security Meeting Summaries Meeting Summaries Green Bay STG Meeting Summary- September 14, 2006 Washington STG Meeting Summary - March 14,...

469

HVAC Design Strategy for a Hot-Humid Production Builder, Houston...  

Energy Savers (EERE)

Size: 1,757 ft 2 to 4,169 ft 2 Price Range: about 260,000 to 450,000 Date Completed: 2013 Climate Zone: Hot-humid PERFORMANCE DATA HERS index: Builder standard practice 66;...

470

International Hydrogen Infrastructure Challenges Workshop Summary...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

International Hydrogen Infrastructure Challenges Workshop Summary - NOW, NEDO, and DOE International Hydrogen Infrastructure Challenges Workshop Summary - NOW, NEDO, and DOE...

471

FY 2009 Summary Report  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

of Performance and financial information FY 2009 DOE/CF-0045 The Reports Consolidation Act of 2000 authorizes Federal agencies, with the Office of Management and Budget's (OMB) concurrence, to consolidate various reports in order to provide performance, financial and related information in a more meaningful and useful format. In accordance with the Act, the Department of Energy (Department or DOE), has produced a consolidated Performance and Accountability Report (PAR) in previous years. For fiscal year (FY) 2009, the Department has chosen to produce an alternative report to the consolidated PAR and will produce an Agency Financial Report, an Annual Performance Report and a Summary of Performance and Financial

472

P9 Summary Presentation  

NLE Websites -- All DOE Office Websites (Extended Search)

Learned Learned WTP Prototypic Mixing and Sampling System Vijay Jain Manager, Research & Technology (Vitrification) May 18-21, 2009 Waste Treatment & Immobilization Plant Project Presented at EM-21 Technical Exchange Denver, CO Jain 04102009 2 Outline Background Test requirements and system design Test status Technical issues during testing Test results Summary Jain 04102009 3 Highlights Testing system is prototypic Major technical and design issues resolved LAW report (3 simulants) - issued HLW & LAW tests - complete Data analyses - 08/09 Reports - 12/09 Jain 04102009 4 Background Compliance to waste specifications is critical to the success of WTP vitrification operations: - Mixing and sampling of waste and melter feed is an integral part

473

Summary Site Environmental Report  

NLE Websites -- All DOE Office Websites (Extended Search)

Site Environmental Report Site Environmental Report for Calendar Year 2011 ANL-12/02 (Summary) Environment, Safety, and Quality Assurance Division Argonne National Laboratory Disclaimer This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor UChicago Argonne, LLC, nor any of their employees or officers, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product,

474

LEAP 1992: Conference summary  

SciTech Connect

We present a summary of the many new results in antiproton ({bar p}) physics presented at the LEAP `92 conference, in the areas of meson spectroscopy, {bar N}N scattering, annihilation and spin observables, strangeness and charm production, {bar N} annihilation in nuclei, atomic physics with very low energy {bar p}`s, the exploration of fundamental symmetries and interactions with {bar p} (CP, T, CPT, gravitation), and the prospects for new {bar p} facilities at ultralow energies or energies above the LEAR regime ({ge} 2 GeV/c).

Dover, C.B.

1992-12-01T23:59:59.000Z

475

LEAP 1992: Conference summary  

SciTech Connect

We present a summary of the many new results in antiproton ([bar p]) physics presented at the LEAP '92 conference, in the areas of meson spectroscopy, [bar N]N scattering, annihilation and spin observables, strangeness and charm production, [bar N] annihilation in nuclei, atomic physics with very low energy [bar p]'s, the exploration of fundamental symmetries and interactions with [bar p] (CP, T, CPT, gravitation), and the prospects for new [bar p] facilities at ultralow energies or energies above the LEAR regime ([ge] 2 GeV/c).

Dover, C.B.

1992-12-01T23:59:59.000Z

476

FY 1996 activity summary  

SciTech Connect

The US Department of Energy Office of Nuclear and Facility Safety provides nuclear safety policy, independent technical evaluation, and technical support. A summary of these activities is provided in this report. These include: (1) changing the mission of the former production facilities to storage and waste management; (2) stabilizing nuclear materials not recycled due to production cessation or interruptions; (3) reformulating the authorization basis for existing facilities to convert to a standards based approach for operations consistent with modern expectations; and (4) implementing a modern regulatory framework for nuclear facilities. Enforcement of the Price-Anderson Amendments Act is also reported.

NONE

1997-04-01T23:59:59.000Z

477

Variation in indoor particle number and PM2.5 concentrations in a radio station surrounded by busy roads before and after an upgrade of the HVAC system  

Science Journals Connector (OSTI)

Indoor particle number and PM2.5 concentrations were investigated in a radio station surrounded by busy roads. Two extensive field measurement campaigns were conducted to determine the critical parameters affecting indoor air quality. The results indicated that indoor particle number and PM2.5 concentrations were governed by outdoor air, and were significantly affected by the location of air intake and design of HVAC system. Prior to the upgrade of the HVAC system and relocation of the air intake, the indoor median particle number concentration was 7.4×103 particles/cm3 and the median PM2.5 concentration was 7 ?g/m3. After the relocation of air intake and the redesign of the HVAC system, the indoor particle number concentration was between 2.3×103 and 3.4×103 particles/cm3, with a median value of 2.7×103 particles/cm3, and the indoor PM2.5 concentration was in the range of 3–5 ?g/m3, with a median value of 4 ?g/m3. By relocating the air intake of the HVAC, the outdoor particle number and PM2.5 concentrations near the air intake were reduced by 35% and 55%, respectively. In addition, with the relocation of air intake and the redesign of the HVAC system, the particle number penetration rate was reduced from 42% to 14%, and the overall filtration efficiency of the HVAC system (relocation of air intake, pre-filter, AHU and particle losses in the air duct) increased from 58% to 86%. For PM2.5, the penetration rate after the upgrade was approximately 18% and the overall filtration efficiency was 82%. This study demonstrates that by using a comprehensive approach, including the assessment of outdoor conditions and characterisation of ventilation and filtration parameters, satisfactory indoor air quality can be achieved, even for those indoor environments facing challenging outdoor air conditions.

L. Morawska; M. Jamriska; H. Guo; E.R. Jayaratne; M. Cao; S. Summerville

2009-01-01T23:59:59.000Z

478

The relationship between filter pressure drop, indoor air quality, and energy consumption in rooftop HVAC units  

Science Journals Connector (OSTI)

Abstract HVAC filters are commonly used to decrease exposure to particulate matter, yet little is known about the energy impacts and air quality consequences of high efficiency filters installed in commercial buildings. To explore these effects, system airflow, filter and coil pressure drop, fan pressure rise, and power draw were measured, and cooling capacity and compressor power were modeled for at least four filter pressure drops in 15 rooftop units equipped with and without fan speed control. Energy implications and clean-air-delivery-rate were estimated for a large dataset of filters divided into four efficiency (MERV) categories. Field measurements conducted on units without fan speed control showed that increased filter pressure drop decreased flow, cooling capacity, and power. For a unit with fan speed control, the same increase in pressure drop resulted in the same magnitude change of fan power but in the opposite direction, and other parameters were unchanged. Replacing MERV 8 with MERV 13/14 resulted in higher energy consumption (2–4%) during cooling mode for both unit types, energy savings during fan-only mode (8–13%) in units without fan speed control, and increased energy consumption in fan-only mode (11–18%) in the unit with fan speed control. Energy consumption increases were offset by improvement in clean-air-delivery-rate, especially for PM2.5 (2.9–3.8 times increase going from MERV 8 to MERV 13/14), with larger benefits achieved for the unit with fan speed control. A comprehensive understanding of the impact of filtration is essential to selecting the appropriate efficiency of filters that ensures low-energy use and a healthy indoor environment.

Marwa Zaatari; Atila Novoselac; Jeffrey Siegel

2014-01-01T23:59:59.000Z

479

Radiant heating and cooling, displacement ventilation with heat recovery and storm water cooling: An environmentally responsible HVAC system  

SciTech Connect

This paper describes the design, operation, and performance of an HVAC system installed as part of a project to demonstrate energy efficiency and environmental responsibility in commercial buildings. The systems installed in the 2180 m{sup 2} office building provide superior air quality and thermal comfort while requiring only half the electrical energy of conventional systems primarily because of the hydronic heating and cooling system. Gas use for the building is higher than expected because of longer operating hours and poor performance of the boiler/absorption chiller.

Carpenter, S.C.; Kokko, J.P. [Enermodal Engineering Ltd., Kitchener, Ontario (Canada)

1998-12-31T23:59:59.000Z

480

Unsaturated Zone I. Overview  

E-Print Network (OSTI)

Chapter 2 Unsaturated Zone I. Overview If the Yucca Mountain site is deemed suitable for re of the extent of welding, the tuffs within the UZ at Yucca Mountain are grouped informally into hydrogeologic Yucca Mountain is illustrated in Figure 2-1 on page 14. A. Why UZ Was Chosen Initial studies of Yucca

Note: This page contains sample records for the topic "hvac zone summary" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Subduction Zone | Open Energy Information  

Open Energy Info (EERE)

Subduction Zone Subduction Zone Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Subduction Zone Dictionary.png Subduction Zone: A tectonic process in which one tectonic plate is forced beneath another and sinks into the mantle as the plates converge Other definitions:Wikipedia Reegle Tectonic Settings List of tectonic settings known to host modern geothermal systems: Extensional Tectonics Subduction Zone Rift Zone Hot Spot Non-Tectonic Strike-Slip A classic cartoon illustrating a typical simplified subduction zone. http://www.columbia.edu/~vjd1/subd_zone_basic.htm Subduction zones occur where one tectonic plate is pulled under another. Most often the subducting plate is oceanic crust and contains many hydrous minerals. As the oceanic plate subducts it dewaters into the mantle,

482

LAI References and Summaries  

NLE Websites -- All DOE Office Websites (Extended Search)

Cart Sign In/Register Quick Data Search Help icon Go NASA Meatball Cart Sign In/Register Quick Data Search Help icon Go NASA Meatball No JAVASCRIPT Capabilities. This site will not function without JavaScript. Please use the Web Product Tree. or anonymous FTP at ftp://daac.ornl.gov/data. Global Leaf Area Index Data from Field Measurements, 1932-2000 References and summaries for literature on leaf area index (reviews, methodology, etc.) Barclay, H. J. (1998) Conversion of total leaf area to projcted leaf area in lodgepole pine and Douglas-fir. Tree PHysiology 18, 185-193. Summary It is noted that three distinct definitions of leaf area index (LAI) in the literature have no predictable relationship with each other. Conversion factors were derived, from total LAI to projected LAI of horizontal leaves and to projected LAI for inclined leaves of lodgepole pine and coastal Douglas-fir, enabling comparison of results from different studies. An algorithm was derived to allow determination of these factors based on twig angles and the angles that the foliage subtends with the twig. The conversion factor was more sensitive to differences in vertical angles of the twigs than to twig rotation or foliar arrangement on the twig.

483

Accommodation Zone | Open Energy Information  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon » Accommodation Zone Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Accommodation Zone Dictionary.png Accommodation Zone: Accommodation zones occur at fault intersections consisting of belts of interlocking, oppositely dipping normal faults. Multiple subsurface fault intersections in these zones are a favorable host for geothermal activity. Other definitions:Wikipedia Reegle Controlling Structures List of controlling structures typically associated with geothermal systems: Major Normal Fault Termination of a Major Normal Fault Stepover or Relay Ramp in Normal Fault Zones

484

Decision Summaries | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

December 13, 2013 Summary of Decisions - December 9, 2013 - December 13, 2013 Decisions were issued on: - Freedom of Information Act Appeal - Personnel Security (10 CFR Part 710)...

485

Decision Summaries | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Act Appeal - Personnel Security (10 CFR Part 710) December 7, 2012 Summary of Decisions - December 3, 2012 - December 7, 2012 Decisions were issued on: - Personnel Security (10 CFR...

486

DOE-ID Operations Summary  

NLE Websites -- All DOE Office Websites (Extended Search)

response to a request from stakeholders for more information on health, safety and environmental incidents at DOE facilities in Idaho. It also includes a brief summary of...

487

Yesterday's Daily Summary - Hanford Site  

NLE Websites -- All DOE Office Websites (Extended Search)

Station Real Time Met Data from Around the Site Current HMS Observations Daily HMS Extremes in Met Data Met and Climate Data Summary Products Historical Weather Charts Contacts...

488

Current Month Summary - Hanford Site  

NLE Websites -- All DOE Office Websites (Extended Search)

Station Real Time Met Data from Around the Site Current HMS Observations Daily HMS Extremes in Met Data Met and Climate Data Summary Products Historical Weather Charts Contacts...

489

Building Technologies Office: Climate Zones  

NLE Websites -- All DOE Office Websites (Extended Search)

Climate Zones to Climate Zones to someone by E-mail Share Building Technologies Office: Climate Zones on Facebook Tweet about Building Technologies Office: Climate Zones on Twitter Bookmark Building Technologies Office: Climate Zones on Google Bookmark Building Technologies Office: Climate Zones on Delicious Rank Building Technologies Office: Climate Zones on Digg Find More places to share Building Technologies Office: Climate Zones on AddThis.com... About Take Action to Save Energy Partner With DOE Activities Solar Decathlon Building America Research Innovations Research Tools Building Science Education Climate-Specific Guidance Solution Center Partnerships Meetings Publications Home Energy Score Home Performance with ENERGY STAR Better Buildings Neighborhood Program Challenge Home Guidelines for Home Energy Professionals

490

Rift Zone | Open Energy Information  

Open Energy Info (EERE)

Rift Zone Rift Zone Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Rift Zone Dictionary.png Rift Zone: A divergent plate boundary within a continent Other definitions:Wikipedia Reegle Tectonic Settings List of tectonic settings known to host modern geothermal systems: Extensional Tectonics Subduction Zone Rift Zone Hot Spot Non-Tectonic Strike-Slip The Rio Grande Rift exemplifies rift zone tectonics - increased volcanic activity and the formation of graben structures (reference: science-art.com) Rift valleys occur at divergent plate boundaries, resulting in large graben structures and increased volcanism. The East African Rift is an example of a continental rift zone with increased volcanism, while the Atlantic's spreading Mid-Ocean Ridge is host to an enormous amount of geothermal

491

The Enterprise Zone (Rhode Island)  

Energy.gov (U.S. Department of Energy (DOE))

The Enterprise Zone offers tax incentives to business expanding their workforce by 5% at facilities in designated enterprise zones. The tax credit is equal to 50% of the annual wages paid to a new...

492

Enterprise Zone | Open Energy Information  

Open Energy Info (EERE)

Zone Jump to: navigation, search This article is a stub. You can help OpenEI by expanding it. Retrieved from "http:en.openei.orgwindex.php?titleEnterpriseZone&oldid542697"...

493

Meeting Summary Notes  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

National Transportation Stakeholders Forum (NTSF) National Transportation Stakeholders Forum (NTSF) May 26, 2010 Meeting Summary Notes Opening Remarks - Steve O'Connor, DOE Office of Packaging and Transportation Steve O'Connor, DOE/EM Office of Packaging and Transportation welcomed the group to this first National Transportation Stakeholders Forum (NTSF) and thanked the planning committee and the dedication of the Midwest Council of State Government for hosting the meeting. The NTSF will focus on transportation across the DOE complex. Mr. O'Connor announced that the meeting would be recorded and questions for the panel could either be written down and passed to the session moderator or asked via the central microphone. Planners for the meeting have worked to ensure a more engaging panel format and to minimize the use of formal presentations. Mr. O'Connor

494

COR Summary of Experience  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

COR SUMMARY OF EXPERIENCE Effective January 1, 2012, the Office of Federal Procurement Policy (OFPP) added a requirement for past COR experience to qualify for FAC-COR Level II (journeyman level) and III (senior/expert level). At least 1 year of COR experience is required to qualify for Level II; 2 years for Level III. OFPP strongly advises that applicants for Level III have prior experience at Level II. Applicants with no prior experience as an appointed COR must demonstrate proficiency in the specific competencies listed below for the same time period, validated by a cognizant Contracting Officer or Contract Specialist by signature below or an accompanying e-mail. Submit this form to your Site Acquisition Career Manager (SACM) as part of your application

495

Compilation of TRA Summaries  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

September 2011 September 2011 Technology Readiness Assessment Summary Number Title Report Date TRA-1 Waste Treatment and Immobilization Plant (WTP) Analytical Laboratory, Balance of Facilities and LAW Waste Vitrification Facilities at Hanford March 2007 TRA-2 Waste Treatment and Immobilization Plant (WTP) HLW Waste Vitrification Facility at Hanford March 2007 TRA-3 Waste Treatment and Immobilization Plant (WTP) Pretreatment Facility at Hanford March 2007 TRA-4 K Basins Sludge Treatment Process at Hanford August 2007 TRA-5 Savannah River Site Tank 48H Waste Treatment Project at SRS July 2007 TRA-6 233Uranium Downblending and Disposition Project at Oak Ridge/ORNL September 2008 TRA-7 SRS Salt Waste Processing Facility at SRS July 2009

496

Summary.qxd  

NLE Websites -- All DOE Office Websites (Extended Search)

S-10 S-10 Summary 3.0 Alternatives For purposes of analysis, DOE used a modular approach in developing alternatives for this EIS. Under this approach, DOE identified a series of discrete projects, which can be linked together in different combinations to achieve the goals of the proposed action. Thus, some projects are included in more than one waste processing alternative. This modular approach provides DOE flexibility in analyzing waste processing alternatives and treatment options and in select- ing the preferred alternative. The facility disposition alternatives analysis con- siders all of the facilities that would be required to implement each waste processing alternative. 3.1 Identifying Alternatives DOE undertook and documented a process to identify the range of reasonable alternatives for

497

Pinellas Remediation Agreement Summary  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Pinellas Pinellas Agreement Name Remediation Agreement for the Four and One-Half Acre Site in Largo, Pinellas County, Florida State Florida Agreement Type Remediation Agreement Legal Driver(s) CERCLA/ Atomic Energy Act of 1954, as amended/ Florida Air and Water Pollution Control Act Scope Summary Remediation of property adjacent to the former Pinellas Plant Parties DOE; Florida Department of Environmental Protection Date 3/12/2001 SCOPE * Remediate the groundwater under a parcel of property adjacent to DOE's former Pinellas Plant to levels consistent with industrial use. * Complete remedial actions at the site in accordance with a Remedial Action Plan prepared by DOE and approved by FDEP. * Submit quarterly reports of interim remedial actions at the Site.

498

Partnership Overview and Summary  

NLE Websites -- All DOE Office Websites (Extended Search)

SWP Phase 3 Deployment Project: SWP Phase 3 Deployment Project: Overview and Summary Brian McPherson and Reid Grigg RCSP Annual Review Meeting October 5-7, 2010 Pittsburgh, PA 2 Acknowledgements * Many thanks to the U.S. Department of Energy and NETL for supporting this project * We express our gratitude also to our many industry partners, who have committed a great deal of time, funding and other general support for these projects * The work presented today is co-authored by all partners in the Southwest Partnership 3 Southwest Regional Partnership In all partner states: * major universities * geologic survey * other state agencies * over 50 partners as well as * Western Governors Association * five major utilities * seven energy companies * three federal agencies * the Navajo Nation * many other critical partners

499

2011 NTSF Meeting Summary  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2 2 National Transportation Stakeholders Forum Denver, Colorado May 11-12, 2011 Meeting Summary Notes The second annual meeting of the National Transportation Stakeholders Forum (NTSF) was held in Denver, Colorado, and was hosted by the Western Governors' Association. Day 1, May 11, 2011 OPENING PLENARY, Keynote: Cynthia Anderson, Chief Operating Officer, Office of Environmental Management, DOE - A Journey to Excellence Ms. Anderson spoke about the Office of Environmental Management's (EM) Journey to Excellence. The mission of EM is to safely transform the environmental legacy of the Cold War into assets available for the Nation's future by completing quality cleanup work on schedule and within cost, delivering demonstrated value to the American taxpayer. Priorities for EM include:

500

FullSummary  

NLE Websites -- All DOE Office Websites (Extended Search)

Selected Selected NERSC Initiative for Scientific Exploration (NISE) Research Summaries: 2010 Project: D ecadal P redictability i n C CSM4 PI: H aiyan T eng a nd G rant B ranstator, NCAR NERSC R epo: m p9 NISE h ours a warded: 1 .6 M With the NISE award, we have carried out two 25---member CCSM4 ensemble experiments with perturbed initial condition. The ensemble experiment has led to findings that should influence the direction of major ongoing international climate research efforts. In order to provide society with the most accurate possible estimates of climate in the coming decades, the scientific community is devoting much effort to initializing some forecasts in the next IPCC assessment report with estimates of the current state of the climate system. The results